WorldWideScience

Sample records for robotic-assisted laparoscopic liver

  1. Robotic assisted laparoscopic colectomy.

    LENUS (Irish Health Repository)

    Pandalai, S

    2010-06-01

    Robotic surgery has evolved over the last decade to compensate for limitations in human dexterity. It avoids the need for a trained assistant while decreasing error rates such as perforations. The nature of the robotic assistance varies from voice activated camera control to more elaborate telerobotic systems such as the Zeus and the Da Vinci where the surgeon controls the robotic arms using a console. Herein, we report the first series of robotic assisted colectomies in Ireland using a voice activated camera control system.

  2. Review: Robot assisted laparoscopic surgery in gynaecological ...

    African Journals Online (AJOL)

    Review: Robot assisted laparoscopic surgery in gynaecological oncology. ... robot suggests "to be able to act without human interference and being able to ... or in space), its use as telesurgery is still very limited and practically not feasible.

  3. [Robot-assisted liver resection].

    Science.gov (United States)

    Aselmann, H; Möller, T; Kersebaum, J-N; Egberts, J H; Croner, R; Brunner, M; Grützmann, R; Becker, T

    2017-06-01

    Robotic liver resection can overcome some of the limitations of laparoscopic liver surgery; therefore, it is a promising tool to increase the proportion of minimally invasive liver resections. The present article gives an overview of the current literature. Furthermore, the results of a nationwide survey on robotic liver surgery among hospitals in Germany with a DaVinci system used in general visceral surgery and the perioperative results of two German robotic centers are presented.

  4. ROBOT-ASSISTED LAPAROSCOPIC PROSTATECTOMY: OUR EXPERIENCE

    Directory of Open Access Journals (Sweden)

    S. N. Nesterov

    2014-08-01

    Full Text Available Background. Retropubic radical prostatectomy (RPE is now the gold standard of treatment for locally advanced prostate cancer (PC. However, robot-assisted RPE procedures using the da Vinci system are finding increasing acceptance.Materials and methods. The authors conducted a prospective study of 60 robot-assisted prostatectomies made at the Clinic of Urology, N.I. Pirogov National Medical Surgical Center, in the period January 2009 to December 2010.Results. The duration of an operation averaged 230 min; the average amount of blood loss was 200 ml. The mean duration of postoperative analgesia was 2,7 days. That of urinary catheterization was 8.5 days. A normal postoperative course was noted in most cases (88,4 %. Seven patients were found to have 8 (13,3 % mild and moderate complications. A pathohistological study revealed a positive surgical margin of resection in 21,7 % of the patients, extracapsular tumor growth in 21,7 %, and seminal vesicle invasion in 23,3 %. Tumor-affected regional lymph nodes were detected in 1 (1,7 % patient. In our observed series, 82 and 93 % of the subjects completely retained urine after 6 and 12 moths, respectively. Throughout the follow-up, erectile function recovered in 7 of the 15 patients undergoing a nerve-sparing surgical procedure.Conclusion. Postoperative results in our series of interventions are comparable to those obtained in the studies by Russian and foreign colleagues at the early stage of mastering this procedure. By considering a few observations, it is today difficult to say that our study is valid in the context of evidence-based medicine. Estimation of the benefits of robot-assisted laparoscopic prostatectomy calls for long-term multicenter randomized trials.

  5. Robotic-assisted versus laparoscopic colectomy: cost and clinical outcomes.

    Science.gov (United States)

    Davis, Bradley R; Yoo, Andrew C; Moore, Matt; Gunnarsson, Candace

    2014-01-01

    Laparoscopic colectomies, with and without robotic assistance, are performed to treat both benign and malignant colonic disease. This study compared clinical and economic outcomes for laparoscopic colectomy procedures with and without robotic assistance. Patients aged ≥18 years having primary inpatient laparoscopic colectomy procedures (cecectomy, right hemicolectomy, left hemicolectomy, and sigmoidectomy) identified by International Classification of Diseases, Ninth Edition procedure codes performed between 2009 and the second quarter of 2011 from the Premier Hospital Database were studied. Patients were matched to a control cohort using propensity scores for disease, comorbidities, and hospital characteristics and were matched 1:1 for specific colectomy procedure. The outcomes of interest were hospital cost of laparoscopic robotic-assisted colectomy compared with traditional laparoscopic colectomy, surgery time, adverse events, and length of stay. Of 25,758 laparoscopic colectomies identified, 98% were performed without robotic assistance and 2% were performed with robotic assistance. After matching, 1066 patients remained, 533 in each group. Lengths of stay were not significantly different between the matched cohorts, nor were rates of major, minor, and/or surgical complications. Inpatient procedures with robotic assistance were significantly more costly than those without robotic assistance ($17,445 vs $15,448, P = .001). Operative times were significantly longer for robotic-assisted procedures (4.37 hours vs 3.34 hours, P < .001). Segmental colectomies can be performed safely by either laparoscopic or robotic-assisted methods. Increased per-case hospital costs for robotic-assisted procedures and prolonged operative times suggest that further investigation is warranted when considering robotic technology for routine laparoscopic colectomies.

  6. Laparoscopic and robot-assisted laparoscopic digestive surgery: Present and future directions

    Science.gov (United States)

    Rodríguez-Sanjuán, Juan C; Gómez-Ruiz, Marcos; Trugeda-Carrera, Soledad; Manuel-Palazuelos, Carlos; López-Useros, Antonio; Gómez-Fleitas, Manuel

    2016-01-01

    Laparoscopic surgery is applied today worldwide to most digestive procedures. In some of them, such as cholecystectomy, Nissen’s fundoplication or obesity surgery, laparoscopy has become the standard in practice. In others, such as colon or gastric resection, the laparoscopic approach is frequently used and its usefulness is unquestionable. More complex procedures, such as esophageal, liver or pancreatic resections are, however, more infrequently performed, due to the high grade of skill necessary. As a result, there is less clinical evidence to support its implementation. In the recent years, robot-assisted laparoscopic surgery has been increasingly applied, again with little evidence for comparison with the conventional laparoscopic approach. This review will focus on the complex digestive procedures as well as those whose use in standard practice could be more controversial. Also novel robot-assisted procedures will be updated. PMID:26877605

  7. Robot assistant versus human or another robot assistant in patients undergoing laparoscopic cholecystectomy.

    Science.gov (United States)

    Gurusamy, Kurinchi Selvan; Samraj, Kumarakrishnan; Fusai, Giuseppe; Davidson, Brian R

    2012-09-12

    The role of a robotic assistant in laparoscopic cholecystectomy is controversial. While some trials have shown distinct advantages of a robotic assistant over a human assistant others have not, and it is unclear which robotic assistant is best. The aims of this review are to assess the benefits and harms of a robot assistant versus human assistant or versus another robot assistant in laparoscopic cholecystectomy, and to assess whether the robot can substitute the human assistant. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) in The Cochrane Library, MEDLINE, EMBASE, and Science Citation Index Expanded (until February 2012) for identifying the randomised clinical trials. Only randomised clinical trials (irrespective of language, blinding, or publication status) comparing robot assistants versus human assistants in laparoscopic cholecystectomy were considered for the review. Randomised clinical trials comparing different types of robot assistants were also considered for the review. Two authors independently identified the trials for inclusion and independently extracted the data. We calculated the risk ratio (RR) or mean difference (MD) with 95% confidence interval (CI) using the fixed-effect and the random-effects models based on intention-to-treat analysis, when possible, using Review Manager 5. We included six trials with 560 patients. One trial involving 129 patients did not state the number of patients randomised to the two groups. In the remaining five trials 431 patients were randomised, 212 to the robot assistant group and 219 to the human assistant group. All the trials were at high risk of bias. Mortality and morbidity were reported in only one trial with 40 patients. There was no mortality or morbidity in either group. Mortality and morbidity were not reported in the remaining trials. Quality of life or the proportion of patients who were discharged as day-patient laparoscopic cholecystectomy patients were not reported in any

  8. Robotic-assisted laparoscopic hysterectomy for women with endometrial cancer

    DEFF Research Database (Denmark)

    Herling, Suzanne Forsyth; Møller, Ann M; Palle, Connie

    2017-01-01

    INTRODUCTION: Robotic-assisted laparoscopic hysterectomy (RALH) has become a widely used approach for women with endometrial cancer and has replaced laparotomy. It has been questioned if the increased costs are justified by superior surgical outcomes. The aim of the present study was to examine...

  9. Robot-assisted laparoscopic myomectomy: current status

    OpenAIRE

    Arian,Sara; Munoz,Jessian; Kim,Suejin; Falcone,Tommaso

    2017-01-01

    Sara E Arian, Jessian L Munoz, Suejin Kim, Tommaso Falcone Department of Obstetrics, Gynecology, and Women’s Health Institute, Cleveland Clinic, Cleveland, OH, USA Abstract: Robotic-assisted surgery has seen a rapid development and integration in the field of gynecology. Since the approval of the use of robot for gynecological surgery and considering its several advantages over conventional laparoscopy, it has been widely incorporated especially in the field of reproductive surgery....

  10. Karolinska prostatectomy: a robot-assisted laparoscopic radical prostatectomy technique.

    Science.gov (United States)

    Nilsson, Andreas E; Carlsson, Stefan; Laven, Brett A; Wiklund, N Peter

    2006-01-01

    The last decade has witnessed an increasing trend towards minimally invasive management of prostate cancer, including laparoscopic and, more recently, robot-assisted laparoscopic prostatectomy. Several different laparoscopic approaches have been continuously developed during the last 5 years and it is still unclear which technique yields the best outcome. We present our current technique of robot-assisted laparoscopic radical prostatectomy. The technique described has evolved during the course of >400 robotic prostatectomies performed by the robotic team since the robot-assisted laparoscopic radical prostatectomy program was introduced at Karolinska University Hospital in January 2002. Our procedure comprises several modifications of previously reported ones, and we utilize fewer robotic instruments to reduce costs. An extended posterior dissection is performed to aid in the bladder neck-sparing dissection. In nerve-sparing procedures the vesicles are divided to avoid damage to the erectile nerves. In order to preserve the apical anatomy the dorsal venous complex is incised sharply and is first over-sewn after the apical dissection is completed. Our technique enables a more fluent dissection than previously described robotic techniques. Minimizing changes of instruments and the camera not only cuts costs but also reduces inefficient operating maneuvers, such as switching between 30 degrees and 0 degrees lenses during the procedure. We present a technique which in our hands has achieved excellent functional and oncological results.

  11. Robotic-assisted laparoscopic management of a caliceal diverticular calculus

    Science.gov (United States)

    Torricelli, Fabio Cesar Miranda; Batista, Lucas T; Colombo, Jose Roberto; Coelho, Rafael Ferreira

    2014-01-01

    Purpose To report the first case of robotic-assisted laparoscopic management of a symptomatic caliceal diverticular calculus and review the literature on laparoscopic treatment for this condition. Case report A 33-year-old obese woman with a 2×1 cm calculus within an anterior caliceal diverticulum located in the middle pole of the left kidney was referred to our service. She had already undergone two flexible ureterorenoscopies without success. We considered that a percutaneous approach would be very challenging due to stone location, thus we elected to perform a robotic-assisted laparoscopic procedure for stone removal and diverticulum fulguration. The procedure was uneventfully performed with no intraoperative or postoperative complications. The patient was discharged from the hospital on the second postoperative day and after 1.5 years of follow-up she is asymptomatic with no recurrence. Conclusions The robotic-assisted laparoscopic approach to caliceal diverticular calculi is feasible and safe, providing one more option for treatment of stones in challenging locations. PMID:25188925

  12. Laparoscopic robot-assisted pancreas transplantation: first world experience.

    Science.gov (United States)

    Boggi, Ugo; Signori, Stefano; Vistoli, Fabio; D'Imporzano, Simone; Amorese, Gabriella; Consani, Giovanni; Guarracino, Fabio; Marchetti, Piero; Focosi, Daniele; Mosca, Franco

    2012-01-27

    Surgical complications are a major disincentive to pancreas transplantation, despite the undisputed benefits of restored insulin independence. The da Vinci surgical system, a computer-assisted electromechanical device, provides the unique opportunity to test whether laparoscopy can reduce the morbidity of pancreas transplantation. Pancreas transplantation was performed by robot-assisted laparoscopy in three patients. The first patient received a pancreas after kidney transplant, the second a simultaneous pancreas kidney transplantation, and the third a pancreas transplant alone. Operations were carried out through an 11-mm optic port, two 8-mm operative ports, and a 7-cm midline incision. The latter was used to introduce the grafts, enable vascular cross-clamping, and create exocrine drainage into the jejunum. The two solitary pancreas transplants required an operating time of 3 and 5 hr, respectively; the simultaneous pancreas kidney transplantation took 8 hr. Mean warm ischemia time of the pancreas graft was 34 min. All pancreatic transplants functioned immediately, and all recipients became insulin independent. The kidney graft, revascularized after 35 min of warm ischemia, also functioned immediately. No patient had complications during or after surgery. At the longer follow-up of 10, 8, and 6 months, respectively, all recipients are alive with normal graft function. We have shown the feasibility of laparoscopic robot-assisted solitary pancreas and simultaneous pancreas and kidney transplantation. If the safety and feasibility of this procedure can be confirmed by larger series, laparoscopic robot-assisted pancreas transplantation could become a new option for diabetic patients needing beta-cell replacement.

  13. The value of contrast-enhanced laparoscopic ultrasound during robotic-assisted surgery for primary colorectal cancer

    DEFF Research Database (Denmark)

    Ellebaek, Signe Bremholm; Fristrup, Claus Wilki; Pless, Torsten

    2018-01-01

    AIM: The aim of this study was to assess the potential clinical value of contrast enhanced laparoscopic ultrasonography (CE-LUS) as a screening modality for liver metastases during robotic assisted surgery for primary colorectal cancer (CRC). METHOD: A prospective, descriptive (feasibility) study...... including 50 consecutive patients scheduled for robotic assisted surgery for primary CRC. CE-LUS was performed by 2 experienced specialists. Only patients without metastatic disease were included. Follow-up was obtained with contrast-enhanced CT imaging at 3 and 12 months postoperatively. RESULTS: Fifty......-up revealed no liver metastasis in any of the patients. CONCLUSION: CE-LUS did not increase the detection rate of occult liver metastasis during robotic assisted primary CRC surgery. The use of CE-LUS as a screening modality for detection of liver metastasis cannot be recommended based on this study...

  14. Robot-assisted laparoscopic (RAL) procedures in general surgery.

    Science.gov (United States)

    Alimoglu, Orhan; Sagiroglu, Julide; Atak, Ibrahim; Kilic, Ali; Eren, Tunc; Caliskan, Mujgan; Bas, Gurhan

    2016-09-01

    Robotics was introduced in clinical practice more than two decades ago, and it has gained remarkable popularity for a wide variety of laparoscopic procedures. We report our results of robot-assisted laparoscopic surgery (RALS) in the most commonly applied general surgical procedures. Ninety seven patients underwent RALS from 2009 to 2012. Indications for RALS were cholelithiasis, gastric carcinoma, splenic tumors, colorectal carcinoma, benign colorectal diseases, non-toxic nodular goiter and incisional hernia. Records of patients were analyzed for demographic features, intraoperative and postoperative complications and conversion to open surgery. Forty six female and 51 male patients were operated and mean age was 58,4 (range: 25-88). Ninety three out of 97 procedures (96%) were completed robotically, 4 were converted to open surgery and there were 15 postoperative complications. There was no mortality. Wide variety of procedures of general surgery can be managed safely and effectively by RALS. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  15. The First Korean Experience of Telemanipulative Robot-Assisted Laparoscopic Cholecystectomy Using the da Vinci System

    Science.gov (United States)

    Kang, Chang Moo; Chi, Hoon Sang; Hyeung, Woo Jin; Kim, Kyung Sik; Choi, Jin Sub; Kim, Byong Ro

    2007-01-01

    With the advancement of laparoscopic instruments and computer sciences, complex surgical procedures are expected to be safely performed by robot assisted telemanipulative laparoscopic surgery. The da Vinci system (Intuitive Surgical, Mountain View, CA, USA) became available at the many surgical fields. The wrist like movements of the instrument's tip, as well as 3-dimensional vision, could be expected to facilitate more complex laparoscopic procedure. Here, we present the first Korean experience of da Vinci robotic assisted laparoscopic cholecystectomy and discuss the introduction and perspectives of this robotic system. PMID:17594166

  16. Robotic-assisted thermal ablation of liver tumours

    International Nuclear Information System (INIS)

    Abdullah, Basri Johan Jeet; Yeong, Chai Hong; Goh, Khean Lee; Yoong, Boon Koon; Ho, Gwo Fuang; Yim, Carolyn Chue Wai; Kulkarni, Anjali

    2015-01-01

    This study aimed to assess the technical success, radiation dose, safety and performance level of liver thermal ablation using a computed tomography (CT)-guided robotic positioning system. Radiofrequency and microwave ablation of liver tumours were performed on 20 patients (40 lesions) with the assistance of a CT-guided robotic positioning system. The accuracy of probe placement, number of readjustments and total radiation dose to each patient were recorded. The performance level was evaluated on a five-point scale (5-1: excellent-poor). The radiation doses were compared against 30 patients with 48 lesions (control) treated without robotic assistance. Thermal ablation was successfully completed in 20 patients with 40 lesions and confirmed on multiphasic contrast-enhanced CT. No procedure related complications were noted in this study. The average number of needle readjustment was 0.8 ± 0.8. The total CT dose (DLP) for the entire robotic assisted thermal ablation was 1382 ± 536 mGy.cm, while the CT fluoroscopic dose (DLP) per lesion was 352 ± 228 mGy.cm. There was no statistically significant (p > 0.05) dose reduction found between the robotic-assisted versus the conventional method. This study revealed that robotic-assisted planning and needle placement appears to be safe, with high accuracy and a comparable radiation dose to patients. (orig.)

  17. Robotic-assisted thermal ablation of liver tumours

    Energy Technology Data Exchange (ETDEWEB)

    Abdullah, Basri Johan Jeet; Yeong, Chai Hong [University of Malaya, Department of Biomedical Imaging and University of Malaya Research Imaging Centre, Faculty of Medicine, Kuala Lumpur (Malaysia); University of Malaya, Department of Internal Medicine, Faculty of Medicine, Kuala Lumpur (Malaysia); Goh, Khean Lee [University of Malaya, Department of Internal Medicine, Faculty of Medicine, Kuala Lumpur (Malaysia); Yoong, Boon Koon [University of Malaya, Department of Surgery, Faculty of Medicine, Kuala Lumpur (Malaysia); Ho, Gwo Fuang [University of Malaya, Department of Oncology, Faculty of Medicine, Kuala Lumpur (Malaysia); Yim, Carolyn Chue Wai [University of Malaya, Department of Anesthesia, Faculty of Medicine, Kuala Lumpur (Malaysia); Kulkarni, Anjali [Perfint Healthcare Corporation, Florence, OR (United States)

    2015-01-15

    This study aimed to assess the technical success, radiation dose, safety and performance level of liver thermal ablation using a computed tomography (CT)-guided robotic positioning system. Radiofrequency and microwave ablation of liver tumours were performed on 20 patients (40 lesions) with the assistance of a CT-guided robotic positioning system. The accuracy of probe placement, number of readjustments and total radiation dose to each patient were recorded. The performance level was evaluated on a five-point scale (5-1: excellent-poor). The radiation doses were compared against 30 patients with 48 lesions (control) treated without robotic assistance. Thermal ablation was successfully completed in 20 patients with 40 lesions and confirmed on multiphasic contrast-enhanced CT. No procedure related complications were noted in this study. The average number of needle readjustment was 0.8 ± 0.8. The total CT dose (DLP) for the entire robotic assisted thermal ablation was 1382 ± 536 mGy.cm, while the CT fluoroscopic dose (DLP) per lesion was 352 ± 228 mGy.cm. There was no statistically significant (p > 0.05) dose reduction found between the robotic-assisted versus the conventional method. This study revealed that robotic-assisted planning and needle placement appears to be safe, with high accuracy and a comparable radiation dose to patients. (orig.)

  18. Fertility and Symptom Relief following Robot-Assisted Laparoscopic Myomectomy

    Directory of Open Access Journals (Sweden)

    Michael C. Pitter

    2015-01-01

    Full Text Available Objective. To examine success of robot-assisted laparoscopic myomectomy (RALM measured by sustained symptom relief and fertility. Methods. This is a retrospective survey of 426 women who underwent RALM for fibroids, symptom relief, or infertility at three practice sites across the US. We examined rates of symptom recurrence and pregnancy and factors associated with these outcomes. Results. Overall, 70% of women reported being symptom-free, with 62.9% free of symptoms after three years. At >3 years, 66.7% of women who underwent surgery to treat infertility and 80% who were also symptom-free reported achieving pregnancy. Factors independently associated with symptom recurrence included greater time after surgery, preoperative dyspareunia, multiple fibroid surgeries, smoking after surgery, and preexisting diabetes. Factors positively correlated with achieving pregnancy included desiring pregnancy, prior pregnancy, greater time since surgery, and Caucasian race. Factors negatively correlated with pregnancy were advanced age and symptom recurrence. Conclusions. This paper, the first to examine symptom recurrence after RALM, demonstrates both short- and long-term effectiveness in providing symptom relief. Furthermore, RALM may have the potential to improve the chance of conception, even in a population at high risk of subfertility, with greater benefits among those who remain symptom-free. These findings require prospective validation.

  19. Robotic Assisted Laparoscopic Prostatectomy after High Intensity Focused Ultrasound Failure

    Directory of Open Access Journals (Sweden)

    Leon Telis

    2017-01-01

    Full Text Available Background. Prostate cancer is the most common cancer diagnosed in men. As new focal therapies become more popular in treatment of prostate cancer, failure cases requiring salvage therapy with either surgical or other techniques are being reported. Objective. To report the options in treatment of prostate cancer after recurrence or failure of the primary treatment modality. Methods. We report a salvage robotic assisted laparoscopic radical prostatectomy (RALP for prostate cancer recurrence following high intensity focused ultrasound treatment (HIFU in the United States. Results. A 67-year-old man who underwent HIFU treatment for prostate adenocarcinoma 2 years prior was presented with a rising prostate specific antigen of 6.1 ng/mL to our clinic. A biopsy proven recurrent disease in the area of previous treatment documented the failure of treatment. The patient elected to undergo a salvage RALP. The operation time was 159 minutes. The patient was discharged from the hospital on postoperative day 1 with no complications. The catheter was removed on post-op day 10. The patient reserved sexual function and urinary continence. The PSA levels on 6 months’ follow-up are undetectable. Conclusions. Salvage RALP is an effective and safe treatment choice for recurrent prostate adenocarcinoma following failed HIFU treatment if operated by an experienced surgeon.

  20. Robotic-assisted laparoscopic hysterectomy versus conventional laparoscopic hysterectomy for benign gynaecological disease

    DEFF Research Database (Denmark)

    Sloth, Sigurd Beier; Rudnicki, Martin; Gimbel, Helga

    Background: In May 2015 the Danish Health and Medicines Authority is publishing a national clinical guideline on hysterectomy for benign gynaecological conditions. One of the key issues assessed in the guideline is the effectiveness of robotic-assisted laparoscopic hysterectomy (RALH) versus...... conventional laparoscopic hysterectomy (LH). Aims: The purpose was to evaluate available evidence on RALH versus LH and to advise surgeons and decision makers in the Danish healthcare system. Methods: A search specialist conducted a systematic literature search. Results were restricted to clinical guidelines...

  1. Robot-Assisted Laparoscopic Management of Caliceal Diverticular Calculi

    Directory of Open Access Journals (Sweden)

    Anneleen Verbrugghe

    2017-07-01

    Full Text Available Standard treatment modalities of caliceal diverticular calculi range from extracorporal shockwave lithotripsy (SWL over retrograde intrarenal surgery (RIRS, percutaneous nephrolithotomy (PNL and laparoscopic stone removal. A 55-year-old woman presented with a history of pyelonephritis based on a caliceal diverticular calculus. Due to the narrow infundibulum and anterior location, a robot-assisted laparoscopic calicotomy with extraction of the calculi and fulguration of the diverticulum was performed, with no specific perioperative problems and good stone-free results. This article shows technical feasibility with minimal morbidity of robot-assisted laparoscopic stone removal and obliteration of a caliceal diverticulum.

  2. Does robotic assistance confer an economic benefit during laparoscopic radical nephrectomy?

    Science.gov (United States)

    Yang, David Y; Monn, M Francesca; Bahler, Clinton D; Sundaram, Chandru P

    2014-09-01

    While robotic assisted radical nephrectomy is safe with outcomes and complication rates comparable to those of the pure laparoscopic approach, there is little evidence of an economic or clinical benefit. From the 2009 to 2011 Nationwide Inpatient Sample database we identified patients 18 years old or older who underwent radical nephrectomy for primary renal malignancy. Robotic assisted and laparoscopic techniques were noted. Patients treated with the open technique and those with evidence of metastatic disease were excluded from analysis. Descriptive statistics were performed using the chi-square and Mann-Whitney tests, and the Student t-test. Multiple linear regression was done to examine factors associated with increased hospital costs and charges. We identified 24,312 radical nephrectomy cases for study inclusion, of which 7,787 (32%) were performed robotically. There was no demographic difference between robotic assisted and pure laparoscopic radical nephrectomy cases. Median total charges were $47,036 vs $38,068 for robotic assisted vs laparoscopic surgery (p robotic assisted surgery were $15,149 compared to $11,735 for laparoscopic surgery (p robotic assistance conferred an estimated $4,565 and $11,267 increase in hospital costs and charges, respectively, when adjusted for adapted Charlson comorbidity index score, perioperative complications and length of stay (p Robotic assisted radical nephrectomy results in increased medical expense without improving patient morbidity. Assuming surgeon proficiency with pure laparoscopy, robotic technology should be reserved primarily for complex surgeries requiring reconstruction. Traditional laparoscopic techniques should continue to be used for routine radical nephrectomy. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  3. Robotic-assisted laparoscopic surgery: recent advances in urology.

    Science.gov (United States)

    Autorino, Riccardo; Zargar, Homayoun; Kaouk, Jihad H

    2014-10-01

    The aim of the present review is to summarize recent developments in the field of urologic robotic surgery. A nonsystematic literature review was performed to retrieve publications related to robotic surgery in urology and evidence-based critical analysis was conducted by focusing on the literature of the past 5 years. The use of the da Vinci Surgical System, a robotic surgical system, has been implemented for the entire spectrum of extirpative and reconstructive laparoscopic kidney procedures. The robotic approach can be applied for a range of adrenal indications as well as for ureteral diseases, including benign and malignant conditions affecting the proximal, mid, and distal ureter. Current evidence suggests that robotic prostatectomy is associated with less blood loss compared with the open surgery. Besides prostate cancer, robotics has been used for simple prostatectomy in patients with symptomatic benign prostatic hyperplasia. Recent studies suggest that minimally invasive radical cystectomy provides encouraging oncologic outcomes mirroring those reported for open surgery. In recent years, the evolution of robotic surgery has enabled urologic surgeons to perform urinary diversions intracorporeally. Robotic vasectomy reversal and several other robotic andrological applications are being explored. In summary, robotic-assisted surgery is an emerging and safe technology for most urologic operations. The acceptance of robotic prostatectomy during the past decade has paved the way for urologists to explore the entire spectrum of extirpative and reconstructive urologic procedures. Cost remains a significant issue that could be solved by wider dissemination of the technology. Copyright © 2014 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  4. Cost-effectiveness of open versus laparoscopic versus robotic-assisted laparoscopic cystectomy and urinary diversion.

    Science.gov (United States)

    Zehnder, Pascal; Gill, Inderbir S

    2011-09-01

    To provide insight into the recently published cost comparisons in the context of open, laparoscopic, and robotic-assisted laparoscopic radical cystectomy and to demonstrate the complexity of such economic analyses. Most economic evaluations are from a hospital perspective and summarize short-term perioperative therapeutic costs. However, the contributing factors (e.g. study design, included variables, robotic amortization plan, supply contract, surgical volume, surgeons' experience, etc.) vary substantially between the institutions. In addition, a real cost-effective analysis considering cost per quality-adjusted life-year gained is not feasible because of the lack of long-term oncologic and functional outcome data with the robotic procedure. On the basis of a modeled cost analysis using results from published series, robotic-assisted cystectomy was - with few exceptions - found to be more expensive when compared with the open approach. Immediate costs are affected most by operative time, followed by length of hospital stay, robotic supply, case volume, robotic cost, and transfusion rate. Any complication substantially impacts overall costs. Economic cost evaluations are complex analyses influenced by numerous factors that hardly allow an interinstitutional comparison. Robotic-assisted cystectomy is constantly refined with many institutions being somewhere on their learning curve. Transparent reports of oncologic and functional outcome data from centers of expertise applying standardized methods will help to properly analyze the real long-term benefits of robotic surgery and successor technologies and prevent us from becoming slaves of successful marketing strategies.

  5. CLINICAL EFFICACY OF THE ROBOT-ASSISTED LAPAROSCOPIC MYOMECTOMY (A REVIEW OF THE LITERATURE

    Directory of Open Access Journals (Sweden)

    V. A. Gudebskaya

    2016-01-01

    Full Text Available Rationale: One of the most complicated and unresolved problems in clinical medicine is the choice of an optimal method for organ-preservation treatment of uterine fibroids in women of childbearing age. Aim: To assess clinical efficacy of robot-assisted laparoscopic myomectomy. Materials and methods: The search was performed in PubMed, Embase, Trip, Cochrane, DocMe databases by keywords: “fibroids”, “robot”, “da Vinci”, “robotic myomectomy”, “robot-assisted myomectomy”. Results: We found 25 publications on robot-assisted laparoscopic myomectomy, including 6  papers on its reproductive outcomes (levels of evidence II–IV. Duration of robot-assisted surgery ranged from 132 to 261 minutes, intraoperative blood loss was in the range from 50 to 387 mL, postoperative hospital stay ranged from 1 to  3.9  days. There was a  lower percentage of intra- and postoperative complications after the robot-assisted interventions, compared to abdominal or classic laparoscopic access, as well as a lower percentage of conversion laparotomies compared to laparoscopy. Pregnancy rates after robotic myomectomy ranged from 16.7 to 69%. Only one case of uterine rupture after robot-assisted laparoscopic myomectomy has been described in the literature. Conclusion: Due to high cost of the method, the number of conducted studies is insufficient to evaluate the role of robotic technologies in the organ-preservation approach to uterine fibroids. Nevertheless, they suggest that robot-assisted laparoscopic myomectomy is justified in women of childbearing age who are planning pregnancy, with big centripetally growing intramural nodes and deformation of the uterine cavity. This technique on its own is an independent method for fertility restoration and could be the first step before the use of assisted reproductive technology.

  6. Transversus abdominis plane (TAP) block after robot-assisted laparoscopic hysterectomy

    DEFF Research Database (Denmark)

    Torup, H; Bøgeskov, M; Hansen, E G

    2015-01-01

    BACKGROUND: Transversus abdominis plane (TAP) block is widely used as a part of pain management after various abdominal surgeries. We evaluated the effect of TAP block as an add-on to the routine analgesic regimen in patients undergoing robot-assisted laparoscopic hysterectomy. METHODS......: In a prospective blinded study, 70 patients scheduled for elective robot-assisted laparoscopic hysterectomy were randomised to receive either TAP block (ropivacaine 0.5%, 20 ml on each side) or sham block (isotonic saline 0.9%, 20 ml on each side). All patients had patient-controlled analgesia (PCA) with morphine...... and Nonsteroidal anti-inflammatory drugs (NSAID) treatment, had no effect on morphine consumption, VAS pain scores, or frequency of nausea and vomiting after robot-assisted laparoscopic hysterectomy compared with paracetamol and NSAID alone....

  7. Laparoscopic hand-assisted versus robotic-assisted laparoscopic sleeve gastrectomy: experience of 103 consecutive cases.

    Science.gov (United States)

    Kannan, Umashankkar; Ecker, Brett L; Choudhury, Rashikh; Dempsey, Daniel T; Williams, Noel N; Dumon, Kristoffel R

    2016-01-01

    Laparoscopic sleeve gastrectomy has become a stand-alone procedure in the treatment of morbid obesity. There are very few reports on the use of robotic approach in sleeve gastrectomy. The purpose of this retrospective study is to report our early experience of robotic-assisted laparoscopic sleeve gastrectomy (RALSG) using a proctored training model with comparison to an institutional cohort of patients who underwent laparoscopic hand-assisted sleeve gastrectomy (LASG). University hospital. The study included 108 patients who underwent sleeve gastrectomy either via the laparoscopic-assisted or robot-assisted approach during the study period. Of these 108 patients, 62 underwent LASG and 46 underwent RALSG. The console surgeon in the RALSG is a clinical year 4 (CY4) surgery resident. All CY4 surgery residents received targeted simulation training before their rotation. The console surgeon is proctored by the primary surgeon with assistance as needed by the second surgeon. The patients in the robotic and laparoscopic cohorts did not have a statistical difference in their demographic characteristics, preoperative co-morbidities, or complications. The mean operating time did not differ significantly between the 2 cohorts (121 min versus 110 min, P = .07). Patient follow-up in the LSG and RALSG were 91% and 90% at 3 months, 62% and 64% at 6 months, and 60% and 55% at 1 year, respectively. The mean percentage estimated weight loss (EWL%) at 3 months, 6 months, and 1 year was greater in the robotic group but not statistically significant (27 versus 22 at 3 mo [P = .05] and 39 versus 34 at 6 mo [P = .025], 57 versus 48 at 1 yr [P = .09]). There was no mortality in either group. Early results of our experience with RALSG indicate low perioperative complication rates and comparable weight loss with LASG. The concept of a stepwise education model needs further validation with larger studies. Copyright © 2016 American Society for Bariatric Surgery. Published by Elsevier Inc

  8. Comparison of precision and speed in laparoscopic and robot-assisted surgical task performance.

    Science.gov (United States)

    Zihni, Ahmed; Gerull, William D; Cavallo, Jaime A; Ge, Tianjia; Ray, Shuddhadeb; Chiu, Jason; Brunt, L Michael; Awad, Michael M

    2018-03-01

    Robotic platforms have the potential advantage of providing additional dexterity and precision to surgeons while performing complex laparoscopic tasks, especially for those in training. Few quantitative evaluations of surgical task performance comparing laparoscopic and robotic platforms among surgeons of varying experience levels have been done. We compared measures of quality and efficiency of Fundamentals of Laparoscopic Surgery task performance on these platforms in novices and experienced laparoscopic and robotic surgeons. Fourteen novices, 12 expert laparoscopic surgeons (>100 laparoscopic procedures performed, no robotics experience), and five expert robotic surgeons (>25 robotic procedures performed) performed three Fundamentals of Laparoscopic Surgery tasks on both laparoscopic and robotic platforms: peg transfer (PT), pattern cutting (PC), and intracorporeal suturing. All tasks were repeated three times by each subject on each platform in a randomized order. Mean completion times and mean errors per trial (EPT) were calculated for each task on both platforms. Results were compared using Student's t-test (P task performance was slower on the robotic platform compared with laparoscopy. In comparisons of expert laparoscopists performing tasks on the laparoscopic platform and expert robotic surgeons performing tasks on the robotic platform, expert robotic surgeons demonstrated fewer errors during the PC task (P = 0.009). Robotic assistance provided a reduction in errors at all experience levels for some laparoscopic tasks, but no benefit in the speed of task performance. Robotic assistance may provide some benefit in precision of surgical task performance. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Arm reduced robotic-assisted laparoscopic hysterectomy with transvaginal cuff closure.

    Science.gov (United States)

    Bodur, Serkan; Dede, Murat; Fidan, Ulas; Firatligil, Burcin F; Ulubay, Mustafa; Ozturk, Mustafa; Yenen, Mufit C

    2017-09-01

    The use of robotics for benign etiology in gynecology has not proven to be more beneficial when compared to traditional laparoscopy. The major concern regarding robotic hysterectomy stems from its high cost. To evaluate the clinical utility and effectiveness of one-arm reduced robotic-assisted laparoscopic hysterectomy as a cost-effective surgical option for total robotic hysterectomy. A sample population of 54 women who underwent robotic-assisted laparoscopic surgery for benign gynecologic indications was evaluated, and two groups were identified: (1) the two-armed robotic-assisted laparoscopic surgery group (n = 38 patients), and (2) the three-armed robotic-assisted laparoscopic surgery group (n = 16 patients). An increased cost was observed when three-armed robotic surgery was employed for benign gynecologic surgery (p < 0.001). The cost reduction observed in the study group was primarily derived from one robotic arm reduction and vaginal closure of the cuff. This cost reduction was achieved without an increase in complication rates or undesirable postoperative outcomes. An estimated profit between $399.5 and $421.5 was made for each patient depending on the suture material chosen for cuff closure. Two-armed surgery resulted in an 18.6% reduction in procedure-specific costs for robotic hysterectomy. Two-armed robotic-assisted laparoscopic hysterectomy appears to be a cost-effective solution for robotic gynecologic surgery. This surgical solution can be performed as effectively as classical three-armed robotic hysterectomies for benign indications without the risk of increased surgical-related morbidities. This approach has the potential to be a widely preferred surgical approach in medical communities where cost reduction is one of the primary determinants of surgery type.

  10. Human capital gains associated with robotic assisted laparoscopic pyeloplasty in children compared to open pyeloplasty.

    Science.gov (United States)

    Behan, James W; Kim, Steve S; Dorey, Frederick; De Filippo, Roger E; Chang, Andy Y; Hardy, Brian E; Koh, Chester J

    2011-10-01

    Robotic assisted laparoscopic pyeloplasty is an emerging, minimally invasive alternative to open pyeloplasty in children for ureteropelvic junction obstruction. The procedure is associated with smaller incisions and shorter hospital stays. To our knowledge previous outcome analyses have not included human capital calculations, especially regarding loss of parental workdays. We compared perioperative factors in patients who underwent robotic assisted laparoscopic and open pyeloplasty at a single institution, especially in regard to human capital changes, in an institutional cost analysis. A total of 44 patients 2 years old or older from a single institution underwent robotic assisted (37) or open (7) pyeloplasty from 2008 to 2010. We retrospectively reviewed the charts to collect demographic and perioperative data. The human capital approach was used to calculate parental productivity losses. Patients who underwent robotic assisted laparoscopic pyeloplasty had a significantly shorter average hospital length of stay (1.6 vs 2.8 days, p human capital gains, eg decreased lost parental wages, and lower hospitalization expenses. Future comparative outcome analyses in children should include financial factors such as human capital loss, which can be especially important for families with young children. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  11. Robotic-assisted laparoscopic partial nephrectomy: initial experience in Brazil and a review of the literature

    Directory of Open Access Journals (Sweden)

    Carlo Camargo Passerotti

    2012-02-01

    Full Text Available CONTEXT AND PURPOSE: Partial nephrectomy has become the standard of care for renal tumors less than 4 cm in diameter. Controversy still exists, however, regarding the best surgical approach, especially when minimally invasive techniques are taken into account. Robotic-assisted laparoscopic partial nephrectomy (RALPN has emerged as a promising technique that helps surgeons achieve the standards of open partial nephrectomy care while offering a minimally invasive approach. The objective of the present study was to describe our initial experience with robotic-assisted laparoscopic partial nephrectomy and extensively review the pertinent literature. MATERIALS AND METHODS: Between August 2009 and February 2010, eight consecutive selected patients with contrast enhancing renal masses observed by CT were submitted to RALPN in a private institution. In addition, we collected information on the patients' demographics, preoperative tumor characteristics and detailed operative, postoperative and pathological data. In addition, a PubMed search was performed to provide an extensive review of the robotic-assisted laparoscopic partial nephrectomy literature. RESULTS: Seven patients had RALPN on the left or right sides with no intraoperative complications. One patient was electively converted to a robotic-assisted radical nephrectomy. The operative time ranged from 120 to 300 min, estimated blood loss (EBL ranged from 75 to 400 mL and, in five cases, the warm ischemia time (WIT ranged from 18 to 32 min. Two patients did not require any clamping. Overall, no transfusions were necessary, and there were no intraoperative complications or adverse postoperative clinical events. All margins were negative, and all patients were disease-free at the 6-month follow-up. CONCLUSIONS: Robotic-assisted laparoscopic partial nephrectomy is a feasible and safe approach to small renal cortical masses.Further prospective studies are needed to compare open partial nephrectomy with

  12. Percutaneous cystostomy drainage for early removing urethral catheter in robotic-assisted laparoscopic radical prostatectomy: Improving on patients' discomfort

    Directory of Open Access Journals (Sweden)

    Che-Jui Yang

    2015-12-01

    Conclusion: The use of a percutaneous cystostomy device is feasible and safe for the early removal of urethral Foley catheter in robotic-assisted laparoscopic radical prostatectomy to decrease penile pain and patient discomfort.

  13. A comparison between robotic-assisted laparoscopic distal pancreatectomy versus laparoscopic distal pancreatectomy.

    Science.gov (United States)

    Goh, Brian K P; Chan, Chung Yip; Soh, Hui-Ling; Lee, Ser Yee; Cheow, Peng-Chung; Chow, Pierce K H; Ooi, London L P J; Chung, Alexander Y F

    2017-03-01

    This study aims to compare the early perioperative outcomes of robotic-assisted laparoscopic distal pancreatectomy (RDP) versus laparoscopic distal pancreatectomy (LDP). The clinicopathologic features of 45 consecutive patients who underwent minimally-invasive distal pancreatectomy from 2006 to 2015 were retrospectively reviewed. Thirty-nine patients who met our study criteria were included. Eight patients underwent RDP and 31 had LDP. There were 10 (25.6%) open conversions. Six (15.4%) patients had major (> grade 2) morbidities and there was no in-hospital mortality. There were 14 (35.9%) grade A and 9 (23.1%) grade B pancreatic fistulas. Comparison between RDP and LDP demonstrated no significant difference between the patients' baseline characteristics except there was increased frequency of spleen-preserving pancreatectomies (3 (37.5%) vs 25 (80.6%), P=0.016) and splenic-vessel preservation (5 (62.5%) vs 4 (12.9%), P=0.003) in RDP. Comparison between outcomes demonstrated that RDP was associated with a longer median operation time (452.5 (range, 300-685) vs 245 min (range, 85-430), P=0.001) and increased frequency of the procedure completed purely laparoscopically (8 (100%) vs 18 (58.1%), P=0.025). RDP can be safely adopted and is equivalent to LDP in most perioperative outcomes. It is also associated with a decreased frequency of the need for hand-assistance laparoscopic surgery or open conversion but needed a longer operation time. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  14. Robot-assisted laparoscopic pyeloplasty: minimum 1-year follow-up

    Science.gov (United States)

    Patel, Vipul; Thaly, Rahul; Shah, Ketul

    2007-02-01

    Objectives: To evaluate the feasibility and efficacy of robotic-assisted laparoscopic pyeloplasty. Laparoscopic pyeloplasty has been shown to have a success rate comparable to that of the open surgical approach. However, the steep learning curve has hindered its acceptance into mainstream urologic practice. The introduction of robotic assistance provides advantages that have the potential to facilitate precise dissection and intracorporeal suturing. Methods: A total of 50 patients underwent robotic-assisted laparoscopic dismembered pyeloplasty. A four-trocar technique was used. Most patients were discharged home on day 1, with stent removal at 3 weeks. Patency of the ureteropelvic junction was assessed in all patients with mercaptotriglycylglycine Lasix renograms at 1, 3, 6, 9, and 12 months, then every 6 months for 1 year, and then yearly. Results: Each patient underwent a successful procedure without open conversion or transfusion. The average estimated blood loss was 40 ml. The operative time averaged 122 minutes (range 60 to 330) overall. Crossing vessels were present in 30% of the patients and were preserved in all cases. The time for the anastomosis averaged 20 minutes (range 10 to 100). Intraoperatively, no complications occurred. Postoperatively, the average hospital stay was 1.1 days. The stents were removed at an average of 20 days (range 14 to 28) postoperatively. The average follow-up was 11.7 months; at the last follow-up visit, each patient was doing well. Of the 50 patients, 48 underwent one or more renograms, demonstrating stable renal function, improved drainage, and no evidence of recurrent obstruction. Conclusions: Robotic-assisted laparoscopic pyeloplasty is a feasible technique for ureteropelvic junction reconstruction. The procedure provides a minimally invasive alternative with good short-term results.

  15. Robot-assisted laparoscopic partial nephrectomy: Current review of the technique and literature.

    Science.gov (United States)

    Singh, Iqbal

    2009-10-01

    To visit the operative technique and to review the current published English literature on the technique, and outcomes following robot-assisted laparoscopic partial nephrectomy (RPN). We searched the published English literature and the PubMed(()) for published series of 'robotic partial nephrectomy' (RPN) using the keywords; robot, robot-assisted laparoscopic partial nephrectomy, laparoscopic partial nephrectomy, partial nephrectomy and laparoscopic surgery. The search yielded 15 major selected series of 'robotic partial nephrectomy'; these were reviewed, tracked and analysed in order to determine the current status and role of RPN in the management of early renal neoplasm(s), as a minimally invasive surgical alternative to open partial nephrectomy. A review of the initial peri-operative outcome of the 350 cases of select series of RPN reported in published English literature revealed a mean operating time, warm ischemia time, estimated blood loss and hospital stay, of 191 minutes, 25 minutes, 162 ml and 2.95 days, respectively. The overall computed mean complication rate of RPN in the present select series was about 7.4%. RPN is a safe, feasible and effective minimally invasive surgical alternative to laparoscopic partial nephrectomy for early stage (T(1)) renal neoplasm(s). It has acceptable initial renal functional outcomes without the increased risk of major complications in experienced hands. Prospective randomised, controlled, comparative clinical trials with laparoscopic partial nephrectomy (LPN) are the need of the day. While the initial oncological outcomes of RPN appear to be favourable, long-term data is awaited.

  16. Novel posterior reconstruction technique during robot-assisted laparoscopic prostatectomy: description and comparative outcomes.

    Science.gov (United States)

    Jeong, Chang Wook; Oh, Jong Jin; Jeong, Seong Jin; Hong, Sung Kyu; Byun, Seok-Soo; Choe, Gheeyoung; Lee, Sang Eun

    2012-07-01

    The aim of the present study was to assess the impact of a novel posterior reconstruction technique during robot-assisted laparoscopic prostatectomy on continence recovery. A total of 116 consecutive patients who received the novel posterior reconstruction (case group) were retrospectively compared with a cohort of 126 patients who did not receive posterior reconstruction (control group). The primary end-point was the duration of continence recovery (no pad use) after robot-assisted laparoscopic prostatectomy. The posterior reconstruction was obtained by opposing the median dorsal fibrous raphe to the posterior counterpart of the detrusor apron, rather than the Denonvilliers' fascia. The case group showed higher continence rates at all points of evaluation, which were 2 weeks (30.1% vs 19.8%), 1 month (58.4% vs 45.7%), 3 months (82.7% vs 70.5%) and 6 months postoperatively (95.3% vs 86.4%) (P = 0.007). Application of the novel posterior reconstruction technique, age and length of membranous urethra were significant variables for the complete recovery of continence on multivariable analysis. This study shows that the application of this novel PR technique significantly improves the recovery of continence in patients undergoing robot-assisted laparoscopic prostatectomy. © 2012 The Japanese Urological Association.

  17. A Comparative Study of Single-Port Laparoscopic Surgery Versus Robotic-Assisted Laparoscopic Surgery for Rectal Cancer

    DEFF Research Database (Denmark)

    Levic, Katarina; Donatsky, Anders Meller; Bulut, Orhan

    2015-01-01

    INTRODUCTION: Conventional laparoscopic surgery is the treatment of choice for many abdominal procedures. To further reduce surgical trauma, new minimal invasive procedures such as single-port laparoscopic surgery (SPLS) and robotic assisted laparoscopic surgery (RALS) have emerged. The aim...... in either of the groups. There was no difference in median follow-up time between groups (P = .58). CONCLUSION: Both SPLS and RALS may have a role in rectal surgery. The short-term oncological outcomes were similar, although RALS harvested more lymph nodes than the SPLS procedure. However, SPLS seems...

  18. Early Experience with Robot-assisted Laparoscopic Radical Prostatectomy

    Directory of Open Access Journals (Sweden)

    Hong Gee Sim

    2004-10-01

    Conclusions: rLRP is feasible in a practice with a low volume of radical prostatectomies. Significant improvement in perioperative parameters occurs after the first eight cases. This technique confers the benefits of enhanced precision and dexterity for complex laparoscopic work in the pelvic cavity.

  19. No differences in short-term morbidity and mortality after robot-assisted laparoscopic versus laparoscopic resection for colonic cancer

    DEFF Research Database (Denmark)

    Helvind, Neel Maria; Eriksen, Jens Ravn; Mogensen, Anders Skibsted

    2013-01-01

    BACKGROUND: Robot-assisted laparoscopy has been reported to be a safe and feasible alternative to traditional laparoscopy. The aim of this study was to compare short-term results in patients with colonic cancer who underwent robot-assisted laparoscopic colonic resection (RC) or laparoscopic colonic...... journals. Biochemical markers [C-reactive protein (CRP), hemoglobin, white blood cell count, and thrombocyte count] were recorded before surgery and for the first 3 days after surgery. RESULTS: A total of 101 patients underwent RC and 162 patients underwent LC. There were no significant differences...... in the rate of conversion to open surgery, number of permanent enterostomies, number of intraoperative complications, level of postoperative cellular stress response, number of postoperative complications, length of postoperative hospital stay, or 30-day mortality between the two groups...

  20. Robot-assisted laparoscopic partial nephrectomy: Current review of the technique and literature

    Directory of Open Access Journals (Sweden)

    Singh Iqbal

    2009-01-01

    Full Text Available Aim: To visit the operative technique and to review the current published English literature on the technique, and outcomes following robot-assisted laparoscopic partial nephrectomy (RPN. Materials and Methods: We searched the published English literature and the PubMed (TM for published series of ′robotic partial nephrectomy′ (RPN using the keywords; robot, robot-assisted laparoscopic partial nephrectomy, laparoscopic partial nephrectomy, partial nephrectomy and laparoscopic surgery. Results: The search yielded 15 major selected series of ′robotic partial nephrectomy′; these were reviewed, tracked and analysed in order to determine the current status and role of RPN in the management of early renal neoplasm(s, as a minimally invasive surgical alternative to open partial nephrectomy. A review of the initial peri-operative outcome of the 350 cases of select series of RPN reported in published English literature revealed a mean operating time, warm ischemia time, estimated blood loss and hospital stay, of 191 minutes, 25 minutes, 162 ml and 2.95 days, respectively. The overall computed mean complication rate of RPN in the present select series was about 7.4%. Conclusions: RPN is a safe, feasible and effective minimally invasive surgical alternative to laparoscopic partial nephrectomy for early stage (T 1 renal neoplasm(s. It has acceptable initial renal functional outcomes without the increased risk of major complications in experienced hands. Prospective randomised, controlled, comparative clinical trials with laparoscopic partial nephrectomy (LPN are the need of the day. While the initial oncological outcomes of RPN appear to be favourable, long-term data is awaited.

  1. Peritoneal Tuberculosis After Robot-Assisted Laparoscopic Prostatectomy with Extended Lymph Node Dissection.

    Science.gov (United States)

    Saito, Suruga; Ito, Katsuhiro; Matsumoto, Keiyu; Tajima, Motofumi; Goto, Takayuki; Ito, Haruki; Manabe, Yumi; Mishina, Mutsuki; Okuno, Hiroshi

    2018-01-01

    Background: Peritoneal tuberculosis (TB) is a relatively uncommon presentation of extrapulmonary TB. Early diagnosis of peritoneal TB is difficult because of its nonspecific clinical manifestation such as abdominal pain, fever, or ascites. Especially early after surgery of abdomen or pelvis, these symptoms can be misdiagnosed as septic peritonitis. There are few reports of peritoneal TB as a postoperative complication of laparoscopic surgery. Here, we describe a first case of peritoneal TB after robot-assisted laparoscopic prostatectomy (RALP) with extended lymph node dissection. Case Presentation: A 78-year-old man presented 25 days after this surgery with fever and abdominal distension. Ultrasonography and computed tomography (CT) revealed massive abdominal ascites. Ascites sample was cloudy, with increased white blood cells and normal creatinine level. No anastomotic leak was found. Bacterial infection of a lymphocele was considered, and cefmetazole 2 g/day for 3 days was prescribed. Despite antibacterial therapy, fever persisted. Polymerase chain reaction testing of ascitic fluid was positive for Mycobacterium tuberculosis . The patient was effectively treated with anti-TB therapy. Conclusion: This is the first report of peritoneal TB as a postoperative complication of RALP with extended lymph node dissection. His preoperative chest CT showed granular shadows in left upper lung, indicating his old asymptomatic TB infection. Flare-up of TB can happen even after robot-assisted laparoscopic surgery, which is minimally invasive. Peritoneal TB must be considered especially when there is unexplained ascites unresponsive to antibiotics.

  2. The learning curve of robot-assisted laparoscopic aortofemoral bypass grafting for aortoiliac occlusive disease.

    Science.gov (United States)

    Novotný, Tomáš; Dvorák, Martin; Staffa, Robert

    2011-02-01

    Since the end of the 20th century, robot-assisted surgery has been finding its role among other minimally invasive methods. Vascular surgery seems to be another specialty in which the benefits of this technology can be expected. Our objective was to assess the learning curve of robot-assisted laparoscopic aortofemoral bypass grafting for aortoiliac occlusive disease in a group of 40 patients. Between May 2006 and January 2010, 40 patients (32 men, 8 women), who were a median age of 58 years (range, 48-75 years), underwent 40 robot-assisted laparoscopic aortofemoral reconstructions. Learning curve estimations were used for anastomosis, clamping, and operative time assessment. For conversion rate evaluation, the cumulative summation (CUSUM) technique was used. Statistical analysis comparing the first and second half of our group, and unilateral-to-bilateral reconstructions were performed. We created 21 aortofemoral and 19 aortobifemoral bypasses. The median proximal anastomosis time was 23 minutes (range, 18-50 minutes), median clamping time was 60 minutes (range, 40-95 minutes), and median operative time was 295 minutes (range, 180-475 minutes). The 30-day mortality rate was 0%, and no graft or wound infection or cardiopulmonary or hepatorenal complications were observed. During the median 18-month follow-up (range, 2-48 months), three early graft occlusions occurred (7%). After reoperations, the secondary patency of reconstructions was 100%. Data showed a typical short learning curve for robotic proximal anastomosis creation with anastomosis and clamping time reduction. The operative time learning curve was flat, confirming the procedure's complexity. There were two conversions to open surgery. CUSUM analysis confirmed that an acceptable conversion rate set at 5% was achieved. Comparing the first and second half of our group, all recorded times showed statistically significant improvements. Differences between unilateral and bilateral reconstructions were not

  3. Robotic-assisted laparoscopic excision of gossypiboma simulating bladder wall mass after 35 years of appendectomy

    Directory of Open Access Journals (Sweden)

    Emad Sabri Rajih

    2014-01-01

    Full Text Available Gossypiboma or textiloma are terms commonly used to describe a retained sponge in the body that is composed of sponge invested within a layer of foreign body reaction in the form of an abscess or an aseptic fibrotic reaction. These cases are rarely reported despite an incidence of 1:1,000-1,500 of abdominal or pelvic surgery. We report a patient who presented with an incidental supravesical mass discovered upon work up for frequency and suprapubic pain. He had appendectomy 35 years ago. The mass was excised by robotic-assisted laparoscopic technique. The pathologic evaluation came as gossypiboma.

  4. Robot-assisted radiofrequency ablation of primary and secondary liver tumours: early experience

    International Nuclear Information System (INIS)

    Abdullah, Basri Johan Jeet; Yeong, Chai Hong; Goh, Khean Lee; Yoong, Boon Koon; Ho, Gwo Fuang; Yim, Carolyn Chue Wai; Kulkarni, Anjali

    2014-01-01

    Computed tomography (CT)-compatible robots, both commercial and research-based, have been developed with the intention of increasing the accuracy of needle placement and potentially improving the outcomes of therapies in addition to reducing clinical staff and patient exposure to radiation during CT fluoroscopy. In the case of highly inaccessible lesions that require multiple plane angulations, robotically assisted needles may improve biopsy access and targeted drug delivery therapy by avoidance of the straight line path of normal linear needles. We report our preliminary experience of performing radiofrequency ablation of the liver using a robotic-assisted CT guidance system on 11 patients (17 lesions). Robotic-assisted planning and needle placement appears to have high accuracy, is technically easier than the non-robotic-assisted procedure, and involves a significantly lower radiation dose to both patient and support staff. (orig.)

  5. Robot-assisted radiofrequency ablation of primary and secondary liver tumours: early experience

    Energy Technology Data Exchange (ETDEWEB)

    Abdullah, Basri Johan Jeet [University of Malaya, Department of Biomedical Imaging, Faculty of Medicine, Kuala Lumpur (Malaysia); Yeong, Chai Hong [University of Malaya, University of Malaya Research Imaging Centre, Faculty of Medicine, Kuala Lumpur (Malaysia); Goh, Khean Lee [University of Malaya, Department of Internal Medicine, Faculty of Medicine, Kuala Lumpur (Malaysia); Yoong, Boon Koon [University of Malaya, Department of Surgery, Faculty of Medicine, Kuala Lumpur (Malaysia); Ho, Gwo Fuang [University of Malaya, Department of Oncology, Faculty of Medicine, Kuala Lumpur (Malaysia); Yim, Carolyn Chue Wai [University of Malaya, Department of Anesthesia, Faculty of Medicine, Kuala Lumpur (Malaysia); Kulkarni, Anjali [Perfint Healthcare Corporation, Florence, OR (United States)

    2014-01-15

    Computed tomography (CT)-compatible robots, both commercial and research-based, have been developed with the intention of increasing the accuracy of needle placement and potentially improving the outcomes of therapies in addition to reducing clinical staff and patient exposure to radiation during CT fluoroscopy. In the case of highly inaccessible lesions that require multiple plane angulations, robotically assisted needles may improve biopsy access and targeted drug delivery therapy by avoidance of the straight line path of normal linear needles. We report our preliminary experience of performing radiofrequency ablation of the liver using a robotic-assisted CT guidance system on 11 patients (17 lesions). Robotic-assisted planning and needle placement appears to have high accuracy, is technically easier than the non-robotic-assisted procedure, and involves a significantly lower radiation dose to both patient and support staff. (orig.)

  6. Tandem-robot assisted laparoscopic radical prostatectomy to improve the neurovascular bundle visualization: a feasibility study.

    Science.gov (United States)

    Han, Misop; Kim, Chunwoo; Mozer, Pierre; Schäfer, Felix; Badaan, Shadie; Vigaru, Bogdan; Tseng, Kenneth; Petrisor, Doru; Trock, Bruce; Stoianovici, Dan

    2011-02-01

    To examine the feasibility of image-guided navigation using transrectal ultrasound (TRUS) to visualize the neurovascular bundle (NVB) during robot-assisted laparoscopic radical prostatectomy (RALP). The preservation of the NVB during radical prostatectomy improves the postoperative recovery of sexual potency. The accompanying blood vessels in the NVB can serve as a macroscopic landmark to localize the microscopic cavernous nerves in the NVB. A novel, robotic transrectal ultrasound probe manipulator (TRUS Robot) and three-dimensional (3-D) reconstruction software were developed and used concurrently with the daVinci surgical robot (Intuitive Surgical, Inc., Sunnyvale, CA) in a tandem-robot assisted laparoscopic radical prostatectomy (T-RALP). After appropriate approval and informed consent were obtained, 3 subjects underwent T-RALP without associated complications. The TRUS Robot allowed a steady handling and remote manipulation of the TRUS probe during T-RALP. It also tracked the TRUS probe position accurately and allowed 3-D image reconstruction of the prostate and surrounding structures. Image navigation was performed by observing the tips of the daVinci surgical instruments in the live TRUS image. Blood vessels in the NVB were visualized using Doppler ultrasound. Intraoperative 3-D image-guided navigation in T-RALP is feasible. The use of TRUS during radical prostatectomy can potentially improve the visualization and preservation of the NVB. Further studies are needed to assess the clinical benefit of T-RALP. Copyright © 2011 Elsevier Inc. All rights reserved.

  7. Comparison of Perioperative Outcomes of Total Laparoscopic and Robotically Assisted Hysterectomy for Benign Pathology during Introduction of a Robotic Program

    Directory of Open Access Journals (Sweden)

    Gokhan Sami Kilic

    2011-01-01

    Full Text Available Study Objective. Prospectively compare outcomes of robotically assisted and laparoscopic hysterectomy in the process of implementing a new robotic program. Design. Prospectively comparative observational nonrandomized study. Design Classification. II-1. Setting. Tertiary caregiver university hospital. Patients. Data collected consecutively 24 months, 34 patients underwent laparoscopic hysterectomy, 25 patients underwent robotic hysterectomy, and 11 patients underwent vaginal hysterectomy at our institution. Interventions. Outcomes of robotically assisted, laparoscopic, and vaginal complex hysterectomies performed by a single surgeon for noncancerous indications. Measurements and Main Results. Operative times were 208.3±59.01 minutes for laparoscopic, 286.2±82.87 minutes for robotic, and 163.5±61.89 minutes for vaginal (<.0001. Estimated blood loss for patients undergoing laparoscopic surgery was 242.7±211.37 cc, 137.4±107.50 cc for robotic surgery, and 243.2±127.52 cc for vaginal surgery (=0.05. The mean length of stay ranged from 1.8 to 2.3 days for the 3 methods. Association was significant for uterine weight (=0.0043 among surgery methods. Conclusion. Robotically assisted hysterectomy is feasible with low morbidity, a shorter hospital stay, and less blood loss. This suggests that robotic assistance facilitates a minimally invasive approach for patients with larger uterine size even during implementing a new robotic program.

  8. Initial consecutive 125 cases of robotic assisted laparoscopic radical prostatectomy performed in Ireland's first robotic radical prostatectomy centre.

    LENUS (Irish Health Repository)

    Bouchier-Hayes, D M

    2012-03-01

    We examined the patient characteristics, operative proceedings and the outcomes of the initial series of 125 cases of robot-assisted laparoscopic radical prostatectomy (RALRP) in an independent hospital in Ireland, performed by two surgeons using the da Vinci(®) surgical system.

  9. Perioperative analgesic requirements in severely obese adolescents and young adults undergoing laparoscopic versus robotic-assisted gastric sleeve resection

    Directory of Open Access Journals (Sweden)

    Anita Joselyn

    2015-01-01

    Full Text Available Purpose: One of the major advantages for patients undergoing minimally invasive surgery as compared to an open surgical procedure is the improved recovery profile and decreased opioid requirements in the perioperative period. There are no definitive studies comparing the analgesic requirements in patients undergoing two different types of minimally invasive procedure. This study retrospectively compares the perioperative analgesic requirements in severely obese adolescents and young adults undergoing laparoscopic versus robotic-assisted, laparoscopic gastric sleeve resection. Materials and Methods: With Institutional Review Board approval, the medication administration records of all severely obese patients who underwent gastric sleeve resection were retrospectively reviewed. Intra-operative analgesic and adjuvant medications administered, postoperative analgesic requirements, and visual analog pain scores were compared between those undergoing a laparoscopic procedure versus a robotic-assisted procedure. Results: This study cohort included a total of 28 patients who underwent gastric sleeve resection surgery with 14 patients in the laparoscopic group and 14 patients in the robotic-assisted group. Intra-operative adjuvant administration of both intravenous acetaminophen and ketorolac was similar in both groups. Patients in the robotic-assisted group required significantly less opioid during the intra-operative period as compared to patients in the laparoscopic group (0.15 ± 0.08 mg/kg vs. 0.19 ± 0.06 mg/kg morphine, P = 0.024. Cumulative opioid requirements for the first 72 postoperative h were similar in both the groups (0.64 ± 0.25 vs. 0.68 ± 0.27 mg/kg morphine, P = NS. No difference was noted in the postoperative pain scores. Conclusion: Although intraoperative opioid administration was lower in the robotic-assisted group, the postoperative opioid requirements, and the postoperative pain scores were similar in both groups.

  10. Robot-assisted laparoscopic versus open partial nephrectomy in patients with chronic kidney disease: A propensity score-matched comparative analysis of surgical outcomes.

    Science.gov (United States)

    Takagi, Toshio; Kondo, Tsunenori; Tachibana, Hidekazu; Iizuka, Junpei; Omae, Kenji; Kobayashi, Hirohito; Yoshida, Kazuhiko; Tanabe, Kazunari

    2017-07-01

    To compare surgical outcomes between robot-assisted laparoscopic partial nephrectomy and open partial nephrectomy in patients with chronic kidney disease. Of 550 patients who underwent partial nephrectomy between 2012 and 2015, 163 patients with T1-2 renal tumors who had an estimated glomerular filtration rate between 30 and 60 mL/min/1.73 m 2 , and underwent robot-assisted laparoscopic partial nephrectomy or open partial nephrectomy were retrospectively analyzed. To minimize selection bias between the two surgical methods, patient variables were adjusted by 1:1 propensity score matching. The present study included 75 patients undergoing robot-assisted laparoscopic partial nephrectomy and 88 undergoing open partial nephrectomy. After propensity score matching, 40 patients were included in each operative group. The mean preoperative estimated glomerular filtration rate was 49 mL/min/1.73 m 2 . The mean ischemia time was 21 min in robot-assisted laparoscopic partial nephrectomy (warm ischemia) and 35 min in open partial nephrectomy (cold ischemia). Preservation of the estimated glomerular filtration rate 3-6 months postoperatively was not significantly different between robot-assisted laparoscopic partial nephrectomy and open partial nephrectomy (92% vs 91%, P = 0.9348). Estimated blood loss was significantly lower in the robot-assisted laparoscopic partial nephrectomy group than in the open partial nephrectomy group (104 vs 185 mL, P = 0.0025). The postoperative length of hospital stay was shorter in the robot-assisted laparoscopic partial nephrectomy group than in the open partial nephrectomy group (P negative surgical margin status were not significantly different between the two groups. In our experience, robot-assisted laparoscopic partial nephrectomy and open partial nephrectomy provide similar outcomes in terms of functional preservation and perioperative complications among patients with chronic kidney disease. However, a lower estimated blood loss and

  11. Ability to Reach Orgasm in Patients with Prostate Cancer Treated with Robot-assisted Laparoscopic Prostatectomy

    DEFF Research Database (Denmark)

    Østby-Deglum, Marie; Axcrona, K; Brennhovd, B.

    2016-01-01

    Objectives To study the ability to reach orgasm after robot-assisted laparoscopic prostatectomy (RALP) in relation to demographic, cancer-related, and surgical variables, and the use of erectile aids. Methods In this cross-sectional study at a mean of 3 years after RALP at Oslo University Hospital......, 982 men were invited to complete a mailed questionnaire, and 777 responded. Respondents who reported postoperative radiotherapy or hormone treatment, or did not report on orgasm were omitted, leaving 609 patients for analysis. Ability to reach orgasm was rated on 1 question from The Expanded Prostate...... Cancer Index Composite 26-item version, and dichotomized into "good" or "poor." Results Overall, 27% of the men reported good ability to reach orgasm: 22% among those did not use erectile aids and 34% among those did (P =.001). Univariate analysis of men with good versus poor ability to reach orgasm...

  12. Robotic-assisted laparoscopic hysterectomy seems safe in women with early-stage endometrial cancer

    DEFF Research Database (Denmark)

    Herling, Suzanne Forsyth; Havemann, Maria Cecilie; Palle, Connie

    2015-01-01

    INTRODUCTION: Robotic surgery is increasingly used in the management of endometrial cancer; and although it is known that minimally invasive surgery reduces post-operative morbidity, the outcomes of this novel treatment should be monitored carefully. The aim of this study was to examine...... the incidence of complications according to the Clavien-Dindo scale after robotic-assisted laparoscopic hysterectomy (RALH) for early-stage endometrial cancer and atypical complex hyperplasia. The Clavien-Dindo scale grades the severity of complications. METHODS: This was a retrospective, descriptive cohort...... study of 235 women with endometrial cancer or atypical complex hyperplasia who had RALH. Surgeries were stratified into two groups: with or without pelvic lymphadenectomy. RESULTS: A total of 6% developed a grade 3 or higher complication with no significant difference (p = 0.24) between the groups...

  13. An actuated force feedback-enabled laparoscopic instrument for robotic-assisted surgery.

    Science.gov (United States)

    Moradi Dalvand, Mohsen; Shirinzadeh, Bijan; Shamdani, Amir Hossein; Smith, Julian; Zhong, Yongmin

    2014-03-01

    Robotic-assisted minimally invasive surgery systems not only have the advantages of traditional laparoscopic instruments but also have other important advantages, including restoring the surgeon's hand-eye coordination and improving the surgeon's precision by filtering hand tremors. Unfortunately, these benefits have come at the expense of the surgeon's ability to feel. Various solutions for restoring this feature have been proposed. An actuated modular force feedback-enabled laparoscopic instrument was proposed that is able to measure tip-tissue lateral interaction forces as well as normal grasping forces. The instrument has also the capability to adjust the grasping direction inside the patient body. In order to measure the interaction forces, strain gauges were employed. A series of finite element analyses were performed to gain an understanding of the actual magnitude of surface strains where gauges are applied. The strain gauge bridge configurations were calibrated. A series of experiments was conducted and the results were analysed. The modularity feature of the proposed instrument makes it interchangeable between various tip types of different functionalities (e.g. cutter, grasper, dissector). Calibration results of the strain gauges incorporated into the tube and at the base of the instrument presented the monotonic responses for these strain gauge configurations. Experimental results from tissue probing and tissue characterization experiments verified the capability of the proposed instrument in measuring lateral probing forces and characterizing artificial tissue samples of varying stiffness. The proposed instrument can improve the quality of palpation and characterization of soft tissues of varying stiffness by restoring sense of touch in robotic assisted minimally invasive surgery operations. Copyright © 2013 John Wiley & Sons, Ltd.

  14. How to set up a robotic-assisted laparoscopic surgery center and training of staff.

    Science.gov (United States)

    Lenihan, John P

    2017-11-01

    The use of computers to assist surgeons in the operating room has been an inevitable evolution in the modern practice of surgery. Robotic-assisted surgery has been evolving now for over two decades and has finally matured into a technology that has caused a monumental shift in the way gynecologic surgeries are performed. Prior to robotics, the only minimally invasive options for most Gynecologic (GYN) procedures including hysterectomies were either vaginal or laparoscopic approaches. However, even with over 100 years of vaginal surgery experience and more than 20 years of laparoscopic advancements, most gynecologic surgeries in the United States were still performed through an open incision. However, this changed in 2005 when the FDA approved the da Vinci Surgical Robotic System tm for use in gynecologic surgery. Over the last decade, the trend for gynecologic surgeries has now dramatically shifted to less open and more minimally invasive procedures. Robotic-assisted surgeries now include not only hysterectomy but also most all other commonly performed gynecologic procedures including myomectomies, pelvic support procedures, and reproductive surgeries. This success, however, has not been without controversies, particularly around costs and complications. The evolution of computers to assist surgeons and make minimally invasive procedures more common is clearly a trend that is not going away. It is now incumbent on surgeons, hospitals, and medical societies to determine the most cost-efficient and productive use for this technology. This process is best accomplished by developing a Robotics Program in each hospital that utilizes robotic surgery. Copyright © 2017. Published by Elsevier Ltd.

  15. Operative technique and early experience for robotic-assisted laparoscopic nephroureterectomy (RALNU) using da Vinci Xi.

    Science.gov (United States)

    Darwiche, Fadi; Swain, Sanjaya; Kallingal, George; Punnen, Sanoj; Manoharan, Murugesan; Parekh, Dipen J; Gonzalgo, Mark L

    2015-01-01

    Robotic-assisted laparoscopic nephroureterectomy (RALNU) has been previously utilized for management of upper tract urothelial carcinoma. The da Vinci Xi surgical system was released in April of 2014. We describe our operative technique and early experience for RALNU using the da Vinci Xi system highlighting unique features of this surgical platform. A total of 10 patients with a diagnosis of upper tract urothelial carcinoma underwent RALNU using the da Vinci Xi system between April and November of 2014. A novel, oblique "in line" robotic trocar configuration was utilized to access the upper abdomen (nephrectomy portion) and pelvis (bladder cuff excision) without undocking. The port hopping feature of da Vinci Xi was utilized to facilitate optimal, multi-quadrant visualization during RALNU. Robotic-assisted laparoscopic nephroureterectomy was successfully completed without open conversion in all 10 patients. Mean operative time was 184 min (range 140-300 min), mean estimated blood loss was 121 cc (range 60-300 cc), and mean hospital stay was 2.4 days. Final pathology demonstrated high grade urothelial carcinoma in all patients. Surgical margins were negative in all patients. No intra-operative complications were encountered. One patient developed a pulmonary embolus after being discharged. No patients required a blood transfusion. Mean patient follow-up was 130 days (range 15-210 days). The use of da Vinci Xi with a novel, oblique "in line" port configuration and camera port hopping technique allows for an efficient and reproducible method for RALNU without the need for repositioning the patient or the robot during surgery.

  16. Intraoperative registered transrectal ultrasound guidance for robot-assisted laparoscopic radical prostatectomy.

    Science.gov (United States)

    Mohareri, Omid; Ischia, Joseph; Black, Peter C; Schneider, Caitlin; Lobo, Julio; Goldenberg, Larry; Salcudean, Septimiu E

    2015-01-01

    To provide unencumbered real-time ultrasound image guidance during robot-assisted laparoscopic radical prostatectomy, we developed a robotic transrectal ultrasound system that tracks the da Vinci® Surgical System instruments. We describe our initial clinical experience with this system. After an evaluation in a canine model, 20 patients were enrolled in the study. During each procedure the transrectal ultrasound transducer was manually positioned using a brachytherapy stabilizer to provide good imaging of the prostate. Then the transrectal ultrasound was registered to the da Vinci robot by a previously validated procedure. Finally, automatic rotation of the transrectal ultrasound was enabled such that the transrectal ultrasound imaging plane safely tracked the tip of the da Vinci instrument controlled by the surgeon, while real-time transrectal ultrasound images were relayed to the surgeon at the da Vinci console. Tracking was activated during all critical stages of the surgery. The transrectal ultrasound robot was easy to set up and use, adding 7 minutes (range 5 to 14) to the procedure. It did not require an assistant or additional control devices. Qualitative feedback was acquired from the surgeons, who found transrectal ultrasound useful in identifying the urethra while passing the dorsal venous complex suture, defining the prostate-bladder interface during bladder neck dissection, identifying the seminal vesicles and their location with respect to the rectal wall, and identifying the distal prostate boundary at the apex. Real-time, registered robotic transrectal ultrasound guidance with automatic instrument tracking during robot-assisted laparoscopic radical prostatectomy is feasible and potentially useful. The results justify further studies to establish whether the approach can improve procedure outcomes. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  17. Outcomes of infants undergoing robot-assisted laparoscopic pyeloplasty compared to open repair.

    Science.gov (United States)

    Dangle, Pankaj P; Kearns, James; Anderson, Blake; Gundeti, Mohan S

    2013-12-01

    Robotic surgery has evolved from simple extirpative surgery to complex reconstructions even in infants. Data are lacking comparing surgical and direct costs to open approaches. We describe the feasibility, salient tips and outcomes of robot-assisted laparoscopic pyeloplasty compared to an open approach. We evaluated patients undergoing open pyeloplasty or robot-assisted laparoscopic pyeloplasty. Ten patients in each group met inclusion criteria. Mean patient age was 3.31 months in the open group and 7.3 months in the robotic group (p=0.02). Postoperative outcomes including length of stay (2.2 vs 2.1 days), estimated blood loss (6.5 vs 7.6 ml), days to regular diet (1 vs 1.1) and days to Foley catheter removal (1.3 vs 1.3) were similar between the open and robotic groups. Total operating time (199 vs 242 minutes) was significantly longer in the robotic group. Postoperative improvement in hydronephrosis was identical in both groups. Direct costs, excluding amortization, robotic cost, maintenance and depreciation, were $4,410 in the open group and $4,979 in the robotic group (p=0.10). In our preliminary experience robotic pyeloplasty in infants is feasible and safe. The immediate outcomes are similar to those of an open approach. The robotic technique in infants currently has the benefits of improved esthetic appearance, improved pain control and similar direct costs compared to the traditional open approach. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  18. Ressecção hepática robótica. Relato de experiência pioneira na América Latina First robotic-assisted laparoscopic liver resection in Latin America

    Directory of Open Access Journals (Sweden)

    Marcel Autran C. Machado

    2009-03-01

    digestive endoscopy disclosed esophageal varices. Five trocars were used. Liver transection was achieved with harmonic scalpel and bipolar forceps. Hemostasis of raw surface areas was accomplished with interrupted stitches. Operative time was 120 minutes. Blood loss was minimal and the patient did not receive transfusion. The recovery was uneventful and patient was discharged on the 3rd postoperative day without ascites formation. Laparoscopic hepatic resection can safely be performed. The laparoscopic approach may enable liver resection in patients with cirrhosis and evidence of liver failure that would contraindicate open surgery probably because it precludes the transection of major abdominal collaterals. The Da Vinci robotic system allowed for technical refinements of laparoscopic liver resection due to 3-dimensional visualization of the operative field and instruments with wrist-type end-effectors.

  19. Current surgical treatment option, utilizing robot-assisted laparoscopic surgery in obese women with endometrial cancer: Farghalys technique

    International Nuclear Information System (INIS)

    Farghaly, S.A.

    2013-01-01

    Background: Endometrial cancer is the most prevalent cancer of the female genital tract in North America. Minimally invasive laparoscopic-assisted surgery and panniculectomy in obese women with endometrial cancer are associated with an improved lymph node count, and lower rate of incisional complications than laparotomy. Methods: Technique for robot-assisted laparoscopic surgery for obese women with endometrial cancer is detailed. Results: Robot-assisted laparoscopic surgical staging, pelvic and para-aortic lymphadenectomy and panniculectomy allow us to avoid the use of postoperative pelvic radiation which is recommended in women with histopathology high-risk findings: deep myometrial invasion or high grade histology. The procedure has the advantage of three-dimensional vision, ergonomic, intuitive control, and wristed instrument that approximate the motion of the human hand. Conclusion: Robot-assisted laparoscopic surgical staging, and panniculectomy in these patients are a safe, and effective alternative to laparoscopic, and laparotomy surgery. It is an ideal tool for performing the complex oncologic procedures encountered in endometrial cancer staging that requires delicate retroperitoneal, pelvic and para-aortic lymph node dissection, while maintaining the principles of oncologic surgery but in a minimally invasive fashion.

  20. Initial Clinical Experience With Surgical Technique of Robot-assisted Transperitoneal Laparoscopic Partial Nephrectomy

    Directory of Open Access Journals (Sweden)

    Cheng-Kuang Yang

    2009-12-01

    Conclusion: Robot-assisted LPN is feasible and may be a viable alternative to open or LPN in selected patients with small exophytic renal tumors. Compared with standard LPN, the robotic assisted LPN approach with precise renal reconstruction under a safe warm ischemia time is feasible and can be easily adopted by those with experience in robot-assisted surgery.

  1. Robot-assisted laparoscopic dismembered pyeloplasty for ureteropelvic junction obstruction: a multi-institutional experience.

    Science.gov (United States)

    Sivaraman, Ananthakrishnan; Leveillee, Raymond J; Patel, Manoj B; Chauhan, Sanket; Bracho, Jorge E; Moore, Charles R; Coelho, Rafael F; Palmer, Kenneth J; Schatloff, Oscar; Bird, Vincent G; Munver, Ravi; Patel, Vipul R

    2012-02-01

    To report a 6-year multi-institutional experience and outcomes with robot-assisted laparoscopic pyeloplasty (RLP) for the repair of ureteropelvic junction obstruction (UPJO). Between June 2002 and October 2008, 168 adult patients from 3 institutions underwent RLP for UPJO. A retrospective analysis of prospectively collected data were performed after institutional review board approval. Diagnosis was by intravenous urogram or computed tomography scan and diuretic renogram. All patients underwent RLP through a 4-port laparoscopic technique. Demographic, preoperative, operative, and postoperative endpoints for primary and secondary repair of UPJO were measured. Success was defined as a T½ of <20 minutes on diuretic renogram and symptom resolution. Pain resolution was assessed by subjective patient reports. Of 168 patients, 147 (87.5%) had primary repairs and 21 (12.5%) had secondary repairs. Of the secondary repairs, 57% had a crossing vessel etiology. Mean operative time was 134.9 minutes, estimated blood loss was 49 mL, and length of stay was 1.5 days. Mean follow-up was 39 months. Overall, 97.6% of patients had a successful outcome, with a 6.6% overall complication rate. To our knowledge, this review represents the largest multi-institutional experience of RLP with intermediate-term follow-up. RLP is a safe, efficacious, and viable option for either primary or secondary repair of UPJO with reproducible outcomes, a high success rate, and a low incidence of complications. Copyright © 2012 Elsevier Inc. All rights reserved.

  2. Robotic-assisted versus laparoscopic colorectal surgery: a meta-analysis of four randomized controlled trials

    Science.gov (United States)

    2014-01-01

    Background Robotic-assisted laparoscopy is popularly performed for colorectal disease. The objective of this meta-analysis was to compare the safety and efficacy of robotic-assisted colorectal surgery (RCS) and laparoscopic colorectal surgery (LCS) for colorectal disease based on randomized controlled trial studies. Methods Literature searches of electronic databases (Pubmed, Web of Science, and Cochrane Library) were performed to identify randomized controlled trial studies that compared the clinical or oncologic outcomes of RCS and LCS. This meta-analysis was performed using the Review Manager (RevMan) software (version 5.2) that is provided by the Cochrane Collaboration. The data used were mean differences and odds ratios for continuous and dichotomous variables, respectively. Fixed-effects or random-effects models were adopted according to heterogeneity. Results Four randomized controlled trial studies were identified for this meta-analysis. In total, 110 patients underwent RCS, and 116 patients underwent LCS. The results revealed that estimated blood losses (EBLs), conversion rates and times to the recovery of bowel function were significantly reduced following RCS compared with LCS. There were no significant differences in complication rates, lengths of hospital stays, proximal margins, distal margins or harvested lymph nodes between the two techniques. Conclusions RCS is a promising technique and is a safe and effective alternative to LCS for colorectal surgery. The advantages of RCS include reduced EBLs, lower conversion rates and shorter times to the recovery of bowel function. Further studies are required to define the financial effects of RCS and the effects of RCS on long-term oncologic outcomes. PMID:24767102

  3. Robotic assisted versus pure laparoscopic surgery of the adrenal glands: a case-control study comparing surgical techniques.

    Science.gov (United States)

    Morelli, Luca; Tartaglia, Dario; Bronzoni, Jessica; Palmeri, Matteo; Guadagni, Simone; Di Franco, Gregorio; Gennai, Andrea; Bianchini, Matteo; Bastiani, Luca; Moglia, Andrea; Ferrari, Vincenzo; Fommei, Enza; Pietrabissa, Andrea; Di Candio, Giulio; Mosca, Franco

    2016-11-01

    The role of the da Vinci Robotic System ® in adrenal gland surgery is not yet well defined. The goal of this study was to compare robotic-assisted surgery with pure laparoscopic surgery in a single center. One hundred and 16 patients underwent minimally invasive adrenalectomies in our department between June 1994 and December 2014, 41 of whom were treated with a robotic-assisted approach (robotic adrenalectomy, RA). Patients who underwent RA were matched according to BMI, age, gender, and nodule dimensions, and compared with 41 patients who had undergone laparoscopic adrenalectomies (LA). Statistical analysis was performed using the Student's t test for independent samples, and the relationship between the operative time and other covariates were evaluated with a multivariable linear regression model. P surgery (p surgery.

  4. A prospective comparison of postoperative pain and quality of life in robotic assisted vs conventional laparoscopic gynecologic surgery.

    Science.gov (United States)

    Zechmeister, Jenna R; Pua, Tarah L; Boyd, Leslie R; Blank, Stephanie V; Curtin, John P; Pothuri, Bhavana

    2015-02-01

    We sought to compare robotic vs laparoscopic surgery in regards to patient reported postoperative pain and quality of life. This was a prospective study of patients who presented for treatment of a new gynecologic disease requiring minimally invasive surgical intervention. All subjects were asked to take the validated Brief Pain Inventory-Short Form at 3 time points to assess pain and its effect on quality of life. Statistical analyses were performed using Pearson x(2) and Student's t test. One hundred eleven were included in the analysis of which 56 patients underwent robotic assisted surgery and 55 patients underwent laparoscopic surgery. There was no difference in postoperative pain between conventional laparoscopy and robotic assisted surgery for gynecologic procedures. There was a statistically significant difference found at the delayed postoperative period when evaluating interference of sleep, favoring laparoscopy (ROB 2.0 vs LSC 1.0; P = .03). There were no differences found between the robotic and laparoscopic groups of patients receiving narcotics (56 vs 53, P = .24, respectively), route of administration of narcotics (47 vs 45, P > .99, respectively), or administration of nonsteroidal antiinflammatory medications (27 vs 21, P = .33, respectively). Our results demonstrate no difference in postoperative pain between conventional laparoscopy and robotic assisted surgery for gynecologic procedures. Furthermore, pain did not appear to interfere consistently with any daily activity of living. Interference of sleep needs to be further evaluated after controlling for bilateral salpingo-oophorectomy. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. [Robot-assisted surgery - Progress or expensive toy? : Matched-pair comparative analysis of robot-assisted cholecystectomy vs. laparoscopic cholecystectomy].

    Science.gov (United States)

    Albrecht, R; Haase, D; Zippel, R; Koch, H; Settmacher, U

    2017-12-01

    By means of a matched-pair analysis comparing data obtained from laparoscopic cholecystectomy (LC) and robot-assisted laparoscopic cholecystectomy (RAC), the value of both methods as well as the advantages and disadvantages of both approaches were elucidated. The consideration was carried out by evaluation of postoperative surgical results, a cost analysis and a subjective survey of the patients using a questionnaire. Thus, from the 35 consecutive RAC, 35 (parallel) retrospectively matched pairs were established. Postoperative surgical results did not show any significant differences between LC and RAC. In the individual assessment by each patient, there were also no significant differences; however, there was a tendency towards the assessment of the RAC to be slightly worse. A striking difference was found with respect to the cost analysis at the time of surgery. The RAC operation alone is significantly more expensive compared to LC with respect to maintenance and acquisition costs. In addition, RAC can at present not be completely reimbursed under the current German diagnosis-related system. The postulated advantages of RAC comprise mainly the precise preparation within narrow confinements and the favorable ergonomic handling for the surgeon. The basic prerequisites are control of the costs and a reasonable reflection in the current reimbursement system.

  6. Robotic assisted laparoscopic adrenalectomy: Initial experience from a tertiary care centre in India

    Directory of Open Access Journals (Sweden)

    Mrinal Pahwa

    2015-01-01

    Full Text Available Introduction: Laparoscopic adrenalectomy (LA is now considered the standard for treatment of surgically correctable adrenal disorders. Robotic adrenalectomy has been performed worldwide and has established itself as safe, feasible and effective approach. We hereby present the first study in robotic transperitoneal LA from Indian subcontinent. Materials and Methods: We conducted a retrospective evaluation of 25 patients who had undergone robotic assisted LA at a tertiary health centre by a single surgeon. Demographic, clinical, histopathological and perioperative outcome data were collected and analysed. Results: Mean age of the patients was 45 years (range: 27-65 years. Eleven male and 14 female patients were operated. Mean operative time was 139 min ± 30 min (range: 110-232 min and mean blood loss was 85 ml ± 12 ml (range: 34-313 ml. Mean hospital stay was 2.5 ± 1.05 days (range: 2-6 days. Mean visual analogue scale score was 3.2 (range: 1-6 mean analgesic requirement was 50 mg diclofenac daily (range: 0-150 mg. Histopathological evaluation revealed 11 adenomas, eight phaeochromocytomas, two adrenocortical carcinomas, and four myelolipomas. According to Clavien-Dindo classification, three patients developed Grade I post-operative complications namely hypotension and pleural effusion. Conclusion: Robotic adrenalectomy is safe, technically feasible and comfortable to the surgeon. It is easier to perform with a short learning curve.

  7. Robotic-assisted laparoscopic hysterectomy seems safe in women with early-stage endometrial cancer

    DEFF Research Database (Denmark)

    Herling, Suzanne Forsyth; Havemann, Maria Cecilie; Palle, Connie

    2015-01-01

    INTRODUCTION: Robotic surgery is increasingly used in the management of endometrial cancer; and although it is known that minimally invasive surgery reduces post-operative morbidity, the outcomes of this novel treatment should be monitored carefully. The aim of this study was to examine the incid......INTRODUCTION: Robotic surgery is increasingly used in the management of endometrial cancer; and although it is known that minimally invasive surgery reduces post-operative morbidity, the outcomes of this novel treatment should be monitored carefully. The aim of this study was to examine...... the incidence of complications according to the Clavien-Dindo scale after robotic-assisted laparoscopic hysterectomy (RALH) for early-stage endometrial cancer and atypical complex hyperplasia. The Clavien-Dindo scale grades the severity of complications. METHODS: This was a retrospective, descriptive cohort....... CONCLUSION: The types and frequency of complications observed in this study resemble those reported in similar studies of RALH for malignant gynaecologic conditions. Health-care professionals treating and caring for women with early-stage endometrial cancer should know of the types and frequency of post...

  8. Prophylactic belladonna suppositories on anesthetic recovery after robotic assisted laparoscopic prostatectomy.

    Science.gov (United States)

    Scavonetto, Federica; Lamborn, David R; McCaffrey, Joan M; Schroeder, Darrell R; Gettman, Mattew T; Sprung, Juraj; Weingarten, Toby N

    2013-06-01

    Two prospective trials have demonstrated prophylactic antimuscarinics following prostatectomy reduce pain from bladder spasms. Our practice adopted the routine administration of prophylactic belladonna and opium (B&O) suppositories to patients undergoing robotic assisted laparoscopic radical prostatectomy (RALP). The aim of this study is to determine if this change in clinical practice was associated with improvement of postoperative outcomes. The medical records of 202 patients that underwent RALP surgery who were or were not administered prophylactic B&O suppositories in the immediate postoperative period were abstracted for duration of anesthesia recovery, pain and analgesic use. Patient and surgical characteristics between groups were similar except B&O group were slightly older (p = 0.04) and administered less opioid analgesics (p = 0.05). There was no difference between groups in the duration of phase I recovery from anesthesia (p = 0.96). Multivariable adjustments for age, body mass index, American Society of Anesthesiologists physical status, and surgical duration were made, and again it was found that suppository administration had no association with phase I recovery times (p = 0.94). The use of antimuscarinic medication for bladder spams in the B&O group was less during phase I recovery (p suppositories at the immediate conclusion of RALP surgery was not associated with improvements of the postoperative course.

  9. The "halo effect" in Korea: change in practice patterns since the introduction of robot-assisted laparoscopic radical prostatectomy.

    Science.gov (United States)

    Sung, Ee-Rah; Jeong, Wooju; Park, Sung Yul; Ham, Won Sik; Choi, Young Deuk; Hong, Sung Joon; Rha, Koon Ho

    2009-03-01

    Acquisition of the da Vinci surgical system (Intuitive Surgical, Mountain View, USA) has enabled robot-assisted surgery to become an acceptable alternative to open radical prostatectomy (ORP). Implementation of robotics at a single institution in Korea induced a gradual increase in the number of performances of robot-assisted laparoscopic radical prostatectomy (RALP) to surgically treat localized prostate cancer. We analyzed the impact of robotic instrumentation on practice patterns among urologists and explain the change in value in ORP and RALP-the standard treatment and the new approach or innovation of robotic technology. The overall number of prostatectomies has increased over time because the number of RALPs has grown drastically whereas the number of OPRs did not decrease during the period of evaluation. Our experience emphasizes the potential of RALP to become the gold standard in the treatment of localized prostate cancer in various parts of the world.

  10. Ability to Reach Orgasm in Patients With Prostate Cancer Treated With Robot-assisted Laparoscopic Prostatectomy.

    Science.gov (United States)

    Østby-Deglum, Marie; Axcrona, Karol; Brennhovd, Bjørn; Dahl, Alv A

    2016-06-01

    To study the ability to reach orgasm after robot-assisted laparoscopic prostatectomy (RALP) in relation to demographic, cancer-related, and surgical variables, and the use of erectile aids. In this cross-sectional study at a mean of 3 years after RALP at Oslo University Hospital, 982 men were invited to complete a mailed questionnaire, and 777 responded. Respondents who reported postoperative radiotherapy or hormone treatment, or did not report on orgasm were omitted, leaving 609 patients for analysis. Ability to reach orgasm was rated on 1 question from The Expanded Prostate Cancer Index Composite 26-item version, and dichotomized into "good" or "poor." Overall, 27% of the men reported good ability to reach orgasm: 22% among those did not use erectile aids and 34% among those did (P = .001). Univariate analysis of men with good versus poor ability to reach orgasm showed many significant differences. In multivariate analysis, being older, having a reduced physical quality of life, and erectile dysfunction were significantly associated with poor ability to reach orgasm. Erectile dysfunction showed an odds ratio of 4.86 for poor orgasmic ability. The 48% of men who used erectile aids had significantly better orgasmic ability than the nonusers. In our sample, 27% had good ability to reach orgasm at a mean of 3 years after RALP. Poor orgasmic ability was associated with being older, poor erectile function, and a reduced physical quality of life. Using erectile aids increased the rate of good ability to reach orgasm. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. The impact of days off between cases on perioperative outcomes for robotic-assisted laparoscopic prostatectomy.

    Science.gov (United States)

    Pearce, Shane M; Pariser, Joseph J; Patel, Sanjay G; Anderson, Blake B; Eggener, Scott E; Zagaja, Gregory P

    2016-02-01

    To examine the effect of days off between cases on perioperative outcomes for robotic-assisted laparoscopic prostatectomy (RALP). We analyzed a single-surgeon series of 2036 RALP cases between 2003 and 2014. Days between cases (DBC) was calculated as the number of days elapsed since the surgeon's previous RALP with the second start cases assigned 0 DBC. Surgeon experience was assessed by dividing sequential case experience into cases 0-99, cases 100-249, cases 250-999, and cases 1000+ based on previously reported learning curve data for RALP. Outcomes included estimated blood loss (EBL), operative time (OT), and positive surgical margins (PSMs). Multiple linear regression was used to assess the impact of the DBC and surgeon experience on EBL, OT, and PSM, while controlling for patient characteristics, surgical technique, and pathologic variables. Overall median DBC was 1 day (0-3) and declined with increasing surgeon case experience. Multiple linear regression demonstrated that each additional DBC was independently associated with increased EBL [β = 3.7, 95% CI (1.3-6.2), p < 0.01] and OT [β = 2.3 (1.4-3.2), p < 0.01], but was not associated with rate of PSM [β = 0.004 (-0.003-0.010), p = 0.2]. Increased experience was also associated with reductions in EBL and OT (p < 0.01). Surgeon experience of 1000+ cases was associated with a 10% reduction in PSM rate (p = 0.03) compared to cases 0-99. In a large single-surgeon RALP series, DBC was associated with increased blood loss and operative time, but not associated with positive surgical margins, when controlling for surgeon experience.

  12. Chylous ascites as a complication of left sided robot-assisted laparoscopic partial nephrectomy

    Directory of Open Access Journals (Sweden)

    Gaurav Pahouja

    2016-10-01

    Full Text Available Objective: The aim of the study was to present a case series of the sparsely reported complication of chylous ascites (CA after left sided robot-assisted laparoscopic partial nephrectomy (RALPN, identify possible risk factors for the development of postoperative CA, and explore current recommendations for identification, management and prevention of CA. Material and methods: A retrospective review of patients that were treated with a RALPN during a one year time period (August 2012 to August 2013 by one surgeon at our institution was conducted. A total of 12 patients were included in the study. Demographics, tumor characteristics, and perioperative outcomes were assessed. Results: Three patients in the study experienced postoperative CA. All three patients had left sided surgery. The initial clinical suspicion for CA was raised due to complaints of abdominal pain with increased milky appearance of JP fluid. JP triglycerides were elevated in all three patients. The patients responded to conservative measures, with two patients treated with medium chain triglyceride diets and one patient treated with total parenteral nutrition (TPN. Among the patients treated with RALPN, the group that was diagnosed with postoperative CA (CA group was found to have a statistically significant lower average body mass index (BMI as compared to the group that did not have CA (non-CA group (24.67 kg/m2 in the CA group versus 31.77 kg/m2 in the non-CA group; P = 0.026. Other demographic data, tumor characteristics, and perioperative outcomes were similar in both groups. Conclusions: CA as a result of RALPN is a newly reported and rare postoperative complication. As utilization of RALPN continues to increase, urologists should be aware of this possible complication and be adept at diagnosing and managing CA. We suggest that left sided retroperitoneal surgery and a lower BMI preoperatively be considered risk factors for developing this complication.

  13. Optic nerve sheath diameter remains constant during robot assisted laparoscopic radical prostatectomy.

    Directory of Open Access Journals (Sweden)

    Philip Verdonck

    Full Text Available During robot assisted laparoscopic radical prostatectomy (RALRP, a CO2 pneumoperitoneum (CO2PP is applied and the patient is placed in a head-down position. Intracranial pressure (ICP is expected to acutely increase under these conditions. A non-invasive method, the optic nerve sheath diameter (ONSD measurement, may warn us that the mechanism of protective cerebrospinal fluid (CSF shifts becomes exhausted.After obtaining IRB approval and written informed consent, ONSD was measured by ocular ultrasound in 20 ASA I-II patients at various stages of the RALRP procedure: baseline awake, after induction, after applying the CO2PP, during head-down position, after resuming the supine position, in the postoperative anaesthesia care unit, and on day one postoperatively. Cerebral perfusion pressure (CPP was calculated as the mean arterial (MAP minus central venous pressure (CVP.The ONSD did not change during head-down position, although the CVP increased from 4.2(2.5 mm Hg to 27.6(3.8 mm Hg. The CPP was decreased 70 min after assuming the head-down position until 15 min after resuming the supine position, but remained above 60 mm Hg at all times.Even though ICP has been documented to increase during CO2PP and head-down positioning, we did not find any changes in ONSD during head-down position. These results indicate that intracranial blood volume does not increase up to a point that CSF migration as a compensation mechanism becomes exhausted, suggesting any increases in ICP are likely to be small.

  14. Learning curve of robot-assisted laparoscopic radical prostatectomy for a single experienced surgeon: comparison with simultaneous laparoscopic radical prostatectomy.

    Science.gov (United States)

    Ku, Ja Yoon; Ha, Hong Koo

    2015-04-01

    Despite the large number of analytical reports regarding the learning curve in the transition from open to robot-assisted radical prostatectomy (RARP), few comparative results with laparoscopic radical prostatectomy (LRP) have been reported. Thus, we evaluated operative and postoperative outcomes in RARP versus 100 simultaneously performed LRPs. A single surgeon had performed more than 1,000 laparoscopic operations, including 415 cases of radical nephrectomy, 85 radical cystectomies, 369 radical prostatectomies, and treatment of 212 other urological tumors, since 2009. We evaluated operative (operation time, intraoperative transfusion, complications, hospital stay, margin status, pathological stage, Gleason score) and postoperative (continence and erectile function) parameters in initial cases of RARP without tutoring compared with 100 recently performed LRPs. Mean operation time and length of hospital stay for RARP and LRP were 145.5±43.6 minutes and 118.1±39.1 minutes, and 6.4±0.9 days and 6.6±1.1 days, respectively (p=0.003 and p=0.721). After 17 cases, the mean operation time for RARP was similar to LRP (less than 2 hours). Positive surgical margins in localized cancer were seen in 11.1% and 8.9% of cases in RARP and LRP, respectively (p=0.733). At postoperative 3 months, sexual intercourse was reported in 14.0% and 12.0%, and pad-free continence in 96.0% and 81.0% in patients with RARP and LRP, respectively (p=0.796 and p=0.012). Previous large-volume experience of LRPs may shorten the learning curve for RARP in terms of oncological outcome. Additionally, previous experience with laparoscopy may improve the functional outcomes of RARP.

  15. Robotic-assisted Heller myotomy versus laparoscopic Heller myotomy for the treatment of esophageal achalasia: a case-control study.

    Science.gov (United States)

    Sánchez, Alexis; Rodríguez, Omaira; Nakhal, Elias; Davila, Hugo; Valero, Rair; Sánchez, Renata; Pena, Romina; Visconti, Maria F

    2012-09-01

    Minimally invasive surgery has become the gold standard for the treatment of achalasia. The incorporation of robotic technology can improve many limitations of laparoscopic surgery, through, for example, the availability of three-dimensional vision, increasing the degrees of movement, avoiding the fulcrum effect and optimizing ergonomics. The aim of this study was to compare robotic-assisted laparoscopic Heller myotomy (RAHM) with laparoscopic Heller myotomy (LHM) in terms of efficacy and safety. Thirty-one patients with diagnosis of achalasia confirmed by esophagogram and manometry were included. Dysphagia and weight loss were the main complaints in both groups. 18 patients were treated with LHM and 13 patients with RAHM. There was no difference in mean operative time (76 ± 13 vs. 79 ± 20 min; P = 0.73). Intraoperative complications were less frequent in the robotic-assisted procedures (5.5% vs. 0%); however, this was a non-significant difference. 94.5-100% of patients had relief of their symptoms. We conclude that RAHM is a safe and effective procedure. The operative time is no longer than in LHM, but it is necessary to evaluate the technique in randomized clinical trials to determine its advantages in terms of intraoperative complications.

  16. A short-term cost-effectiveness study comparing robot-assisted laparoscopic and open retropubic radical prostatectomy

    DEFF Research Database (Denmark)

    Hohwü, Lena; Borre, Michael; Ehlers, Lars

    2011-01-01

    OBJECTIVE: To evaluate cost effectiveness and cost utility comparing robot-assisted laparoscopic prostatectomy (RALP) versus retropubic radical prostatectomy (RRP). METHODS: In a retrospective cohort study a total of 231 men between the age of 50 and 69 years and with clinically localised prostate....... An economic evaluation was made to estimate direct costs of the first postoperative year and an incremental cost-effectiveness ratio (ICER) per successful surgical treatment and per quality-adjusted life-year (QALY). A successful RP was defined as: no residual cancer (PSA ... high volume urology centres and utilise the full potential of each robot....

  17. Unidirectional barbed suture versus standard monofilament for urethrovesical anastomosis during robotic assisted laparoscopic radical prostatectomy

    Directory of Open Access Journals (Sweden)

    Marc Manganiello

    2012-02-01

    Full Text Available PURPOSE: V-LocTM180 (Covidien Healthcare, Mansfield, MA is a new unidirectional barbed suture that may reduce loss of tension during a running closure. We evaluated the use of the barbed suture for urethrovesical anastomosis (UVA during robotic assisted laparoscopic prostatectomy (RALP. Time to completion of UVA, post-operative anastomotic leak rate, and urinary incontinence were compared in patients undergoing UVA with 3-0 unidirectional-barbed suture vs. 3-0 MonocrylTM (Ethicon, Somerville, NJ. MATERIALS AND METHODS: Data were prospectively collected for 70 consecutive patients undergoing RALP for prostate cancer between November 2009 and October 2010. In the first 35 patients, the UVA was performed using a modified running van Velthoven anastomosis technique using two separate 3-0 monofilament sutures. In the subsequent 35 patients, the UVA was performed using two running novel unidirectional barbed sutures. At 7-12 days postoperatively, all patients were evaluated with a cystogram to determine anastomotic integrity. Urinary incontinence was assessed at two months and five months by total daily pad usage. Clinical symptoms suggestive of bladder neck contracture were elicited. RESULTS: Age, PSA, Gleason score, prostate size, estimated blood loss, body mass index, and clinical and pathologic stage between the 2 groups were similar. Comparing the monofilament group and V-LocTM180 cohorts, average time to complete the anastomosis was similar (27.4 vs. 26.4 minutes, p = 0.73 as was the rate of urinary extravasation on cystogram (5.7 % vs. 8.6%, p = 0.65. There were no symptomatic bladder neck contractures noted at 5 months of follow-up. At 2 months, the percentage of patients using 2 or more pads per day was lower in the V-LocTM180 cohort (24% vs. 44%, p < 0.02. At 5 months, this difference was no longer evident. CONCLUSIONS: Time to complete the UVA was similar in the intervention and control groups. Rates of urine leak were also comparable

  18. Robot-assisted laparoscopic radical prostatectomy with early retrograde release of the neurovascular bundle and endopelvic fascia sparing

    Directory of Open Access Journals (Sweden)

    George Augusto Monteiro Lins de Albuquerque

    Full Text Available ABSTRACT Introduction Robotic-assisted radical prostatectomy (RAP is the dominant minimally invasive surgical treatment for patients with localized prostate cancer. The introduction of robotic assistance has the potential to improve surgical outcomes and reduce the steep learning curve associated with conventional laparoscopic radical prostatectomy. The purpose of this video is to demonstrate the early retrograde release of the neurovascular bundle without open the endopelvic fascia during RAP. Materials and Methods A 51-year old male, presenting histological diagnosis of prostate adenocarcinoma, Gleason 6 (3+3, in 4 cores of 12, with an initial PSA=3.41ng/dl and the digital rectal examination demonstrating a prostate with hardened nodule in the right lobe of the prostate base (clinical stage T2a. Surgical treatment with the robot-assisted technique was offered as initial therapeutic option and the critical technical point was the early retrograde release of the neurovascular bundle with endopelvic fascia preservation, during radical prostatectomy. Results The operative time was of 89 minutes, blood loss was 100ml. No drain was left in the peritoneal cavity. The patient was discharged within 24 hours. There were no intraoperative or immediate postoperative complications. The pathological evaluation revealed prostate adenocarcinoma, Gleason 6, with free surgical margins and seminal vesicles free of neoplastic involvement (pathologic stage T2a. At 3-month-follow-up, the patient lies with undetectable PSA, continent and potent. Conclusion This is a feasible technique combining the benefits of retrograde release of the neurovascular bundle, the preservation of the pubo-prostatic collar and the preservation of the antero-lateral cavernous nerves.

  19. The new era of minimally invasive interventions for prostate cancer: robot-assisted laparoscopic radical prostatectomy and focal therapy

    Directory of Open Access Journals (Sweden)

    Schatloff O

    2011-10-01

    Full Text Available Oscar Schatloff1, Alyssa S Louis2, Uri Lindner21Global Robotics Institute, Florida Hospital Celebration Health, Celebration, FL, USA; 2Division of Urology, Department of Surgical Oncology, University Health Network, Toronto, ON, CanadaAbstract: Prostate cancer remains a common but highly treatable disease. Innovations in prostate cancer treatment have allowed a transition toward minimally invasive approaches in an attempt to avoid treatment-related morbidities. In the middle of the treatment spectrum between radical open surgeries and active surveillance lies robot-assisted laparoscopic radical prostatectomy (RALP and focal therapy (FT. This review sets out the most current information on RALP and FT (including laser ablation, cryotherapy, high-intensity focused ultrasound, photodynamic therapy, and irreversible electroporation.Keywords: PCa, RALP, FT, laser ablation, cryotherapy, high-intensity focused ultrasound, photodynamic therapy, irreversible electroporation

  20. Lumbosacral osteomyelitis after robot-assisted total laparoscopic hysterectomy and sacral colpopexy.

    Science.gov (United States)

    Muffly, Tyler M; Diwadkar, Gouri B; Paraiso, Marie Fidela R

    2010-12-01

    We report on the transabdominal resection of infected lumbosacral bone, synthetic mesh, and sinus tract following sacral colpopexy. A 45-year-old nulliparous patient who had undergone transvaginal mesh followed by robot-assisted sacral colpopexy presented with increasing back pain and foul-smelling vaginal drainage. An epidural abscess required surgical intervention, including diskectomy, sacral debridement, and mesh removal to drain the abscess and vaginal sinus tract. Recognized complications of open prolapse procedures also manifest following minimally invasive approaches. Osteomyelitis of the sacral promontory following sacral colpopexy may require gynecologic and neurosurgical management.

  1. Robot-assisted general surgery.

    Science.gov (United States)

    Hazey, Jeffrey W; Melvin, W Scott

    2004-06-01

    With the initiation of laparoscopic techniques in general surgery, we have seen a significant expansion of minimally invasive techniques in the last 16 years. More recently, robotic-assisted laparoscopy has moved into the general surgeon's armamentarium to address some of the shortcomings of laparoscopic surgery. AESOP (Computer Motion, Goleta, CA) addressed the issue of visualization as a robotic camera holder. With the introduction of the ZEUS robotic surgical system (Computer Motion), the ability to remotely operate laparoscopic instruments became a reality. US Food and Drug Administration approval in July 2000 of the da Vinci robotic surgical system (Intuitive Surgical, Sunnyvale, CA) further defined the ability of a robotic-assist device to address limitations in laparoscopy. This includes a significant improvement in instrument dexterity, dampening of natural hand tremors, three-dimensional visualization, ergonomics, and camera stability. As experience with robotic technology increased and its applications to advanced laparoscopic procedures have become more understood, more procedures have been performed with robotic assistance. Numerous studies have shown equivalent or improved patient outcomes when robotic-assist devices are used. Initially, robotic-assisted laparoscopic cholecystectomy was deemed safe, and now robotics has been shown to be safe in foregut procedures, including Nissen fundoplication, Heller myotomy, gastric banding procedures, and Roux-en-Y gastric bypass. These techniques have been extrapolated to solid-organ procedures (splenectomy, adrenalectomy, and pancreatic surgery) as well as robotic-assisted laparoscopic colectomy. In this chapter, we review the evolution of robotic technology and its applications in general surgical procedures.

  2. Robot-assisted versus conventional laparoscopic operation in anus-preserving rectal cancer: a meta-analysis

    Directory of Open Access Journals (Sweden)

    Cui Y

    2017-09-01

    Full Text Available Yongzhen Cui,1,2,* Cheng Li,3,* Zhongfa Xu,4 Yingming Wang,1,2 Yamei Sun,5 Huirong Xu,1 Zengjun Li,1 Yanlai Sun1 1Department of Gastrointestinal Cancer Surgery, Shandong Cancer Hospital Affiliated to Shandong University, Shandong Academy of Medical Sciences, 2School of Medicine and Life Sciences, University of Jinan-Shandong Academy of Medical Sciences, 3Department of President’s Office, Shandong Cancer Hospital Affiliated to Shandong University, Shandong Academy of Medical Sciences, 4Department of Gastrointestinal Surgery, The Affiliated Hospital of Shandong Academy of Medical Sciences, Jinan, 5Department of Clinical Laboratory, Zhucheng People’s Hospital of Shandong Province, Zhucheng, People’s Republic of China *These authors contributed equally to this work Objective: The aim of this meta-analysis is to provide recommendations for clinical practice and prevention of postoperative complications, such as circumferential resection margin (CRM involvement, and compare the amount of intraoperative bleeding, safety, operative time, recovery, outcomes, and clinical significance of robot-assisted and conventional laparoscopic procedures in anus-preserving rectal cancer. Methods: A literature search (PubMed was performed to identify biomedical research papers and abstracts of studies comparing robot-assisted and conventional laparoscopic procedures. We attempted to obtain the full-text link for papers published between 2000 and 2016, and hand-searched references for relevant literature. RevMan 5.3 software was used for the meta-analysis. Results: Nine papers (949 patients were eligible for inclusion; there were 473 patients (49.8% in the robotic group and 476 patients (50.2% in the laparoscopic group. According to the data provided in the literature, seven indicators were used to complete the evaluation. The results of the meta-analysis suggested that robot-assisted procedure was associated with lower intraoperative blood loss (mean difference

  3. Solo surgery--early results of robot-assisted three-dimensional laparoscopic hysterectomy.

    Science.gov (United States)

    Tuschy, Benjamin; Berlit, Sebastian; Brade, Joachim; Sütterlin, Marc; Hornemann, Amadeus

    2014-08-01

    Report of our initial experience in laparoscopic hysterectomy by a solo surgeon using a robotic camera system with three-dimensional visualisation. This novel device (Einstein Vision®, B. Braun, Aesculap AG, Tuttlingen, Germany) (EV) was used for laparoscopic supracervical hysterectomy (LASH) performed by one surgeon. Demographic data, clinical and surgical parameters were evaluated. Our first 22 cases, performed between June and November 2012, were compared with a cohort of 22 age-matched controls who underwent two-dimensional LASH performed by the same surgeon with a second surgeon assisting. Compared to standard two-dimensional laparoscopic hysterectomy, there were no significant differences regarding duration of surgery, hospital stay, blood loss or incidence of complications. The number of trocars used was significantly higher in the control group (p solo surgery laparoscopic hysterectomy is a feasible and safe procedure. Duration of surgery, hospital stay, blood loss, and complication rates are comparable to a conventional laparoscopic hysterectomy.

  4. Anastomotic complications after robot-assisted laparoscopic and open radical prostatectomy

    DEFF Research Database (Denmark)

    Jacobsen, André; Berg, Kasper Drimer; Iversen, Peter

    2016-01-01

    Objective Anastomotic complications are well known after radical prostatectomy (RP). The vesicourethral anastomotic technique is handled differently between open and robotic RP. The aim of the study was to investigate whether the frequency of anastomotic leakages and strictures differed between...... patients undergoing retropubic radical prostatectomy (RRP) and robot-assisted radical prostatectomy (RARP) and to identify risk factors associated with these complications. Materials and methods The study included 735 consecutive patients who underwent RRP (n = 499) or RARP (236) at the Department...... of Urology, Rigshospitalet, Denmark, in a complete 3 year period from 2010 to 2012. Univariate and multivariate logistic regression analysis was used to analyse associations between surgical procedure (RRP vs RARP) and anastomotic complications. Analyses included age, smoking status, diabetes, hypertension...

  5. Cost-analysis of robotic-assisted laparoscopic hysterectomy versus total abdominal hysterectomy for women with endometrial cancer and atypical complex hyperplasia

    DEFF Research Database (Denmark)

    Herling, Suzanne Forsyth; Palle, Connie; Møller, Ann M.

    2016-01-01

    INTRODUCTION: The aim of this study was to analyse the hospital cost of treatment with robotic-assisted laparoscopic hysterectomy and total abdominal hysterectomy for women with endometrial cancer or atypical complex hyperplasia and to identify differences in resource use and cost. MATERIAL...... AND METHODS: This cost analysis was based on two cohorts: women treated with robotic-assisted laparoscopic hysterectomy (n = 202) or with total abdominal hysterectomy (n = 158) at Copenhagen University Hospital, Herlev, Denmark. We conducted an activity-based cost analysis including consumables and healthcare...... professionals' salaries. As cost-drivers we included severe complications, duration of surgery, anesthesia and stay at the post-anesthetic care unit, as well as number of hospital bed-days. Ordinary least-squares regression was used to explore the cost variation. The primary outcome was cost difference...

  6. An unexpected resident in the ileum detected during robot-assisted laparoscopic radical cystoprostatectomy and intracorporeal Studer pouch formation: Taenia saginata parasite.

    Science.gov (United States)

    Canda, Abdullah Erdem; Asil, Erem; Balbay, Mevlana Derya

    2011-02-01

    A case of moving ileal Taenia saginata parasites is presented with demonstrative images. We came across the parasites surprisingly while performing robot-assisted laparoscopic radical cystoprostatectomy with intracorporeal Studer pouch urinary diversion. We recommend stool sample evaluation in the preoperative period for possible presence of intestinal parasitic diseases, particularly in patients with bladder cancer who are admitted from areas with an increased incidence of intestinal parasitic diseases, before opening the bowel segments during surgery to perform radical cystectomy and urinary diversion.

  7. Comparative health technology assessment of robotic-assisted, direct manual laparoscopic and open surgery: a prospective study.

    Science.gov (United States)

    Turchetti, Giuseppe; Pierotti, Francesca; Palla, Ilaria; Manetti, Stefania; Freschi, Cinzia; Ferrari, Vincenzo; Cuschieri, Alfred

    2017-02-01

    Despite many publications reporting on the increased hospital cost of robotic-assisted surgery (RAS) compared to direct manual laparoscopic surgery (DMLS) and open surgery (OS), the reported health economic studies lack details on clinical outcome, precluding valid health technology assessment (HTA). The present prospective study reports total cost analysis on 699 patients undergoing general surgical, gynecological and thoracic operations between 2011 and 2014 in the Italian Public Health Service, during which period eight major teaching hospitals treated the patients. The study compared total healthcare costs of RAS, DMLS and OS based on prospectively collected data on patient outcome in addition to healthcare costs incurred by the three approaches. The cost of RAS operations was significantly higher than that of OS and DMLS for both gynecological and thoracic operations (p DMLS. Total costs of general surgery RAS were significantly higher than those of OS (p DMLS general surgery. Indirect costs were significantly lower in RAS compared to both DMLS general surgery and OS gynecological surgery due to the shorter length of hospital stay of RAS approach (p < 0.001). Additionally, in all specialties compared to OS, patients treated by RAS experienced a quicker recovery and significantly less pain during the hospitalization and after discharge. The present HTA while confirming higher total healthcare costs for RAS operations identified significant clinical benefits which may justify the increased expenditure incurred by this approach.

  8. Feasibility and early outcomes of robotic-assisted laparoscopic Mitrofanoff appendicovesicostomy in patients with prune belly syndrome.

    Science.gov (United States)

    Wille, Mark A; Jayram, Gautam; Gundeti, Mohan S

    2012-01-01

    To evaluate the feasibility and report our initial experience with Robotic-Assisted Laparoscopic Mitrofanoff Appendicovesicostomy (RALMA) in patients with prune belly syndrome. The Mitrofanoff appendicovesicostomy procedure uses the appendix to create an easily accessible continent, catheterizable channel into the urinary bladder. Historically, the procedure is performed by an open surgical approach in prune belly patients. We describe our initial experience herein. Between October 2008 and February 2010 three patients with prune belly syndrome underwent RALMA. The appendicovesicostomy anastomosis was performed on the anterior bladder wall and the stoma was brought to the umbilical site or right lower quadrant. At least 4 cm of detrusor backing was ensured. The appendicovesicostomy stent was left in place for 4 weeks postoperatively before initiation of catheterization. Mean age at surgery was 9.7 years (range 5-14 years). Blood loss volume was 20 mL in each case. Overall mean operative time was 352 min (range 319-402 min). There were no intraoperative complications and no open conversions. There was one postoperative complication in the form of wound infection. All patients are catheterizing their stomas and are continent at an average follow-up of 14.7 months (range 5-21 months). In our initial experience, RALMA is a feasible option with encouraging early experience for creating a continent catheterizable channel into the urinary bladder in patients with prune belly syndrome. © 2011 THE AUTHORS. BJU INTERNATIONAL © 2011 BJU INTERNATIONAL.

  9. Noninvasive continuous blood pressure monitoring by the ClearSight system during robot-assisted laparoscopic radical prostatectomy.

    Science.gov (United States)

    Sakai, Yoko; Yasuo M, Tsutsumi; Oyama, Takuro; Murakami, Chiaki; Kakuta, Nami; Tanaka, Katsuya

    2018-01-01

    Robot-assisted laparoscopic radical prostatectomy (RALRP) is commonly performed in the surgical treatment of prostate cancer. However, the steep Trendelenburg position (25) and pneumoperitoneum required for this procedure can sometimes cause hemodynamic changes. Although blood pressure is traditionally monitored invasively during RALRP, the ClearSight system (BMEYE, Amsterdam, The Netherlands) enables a totally noninvasive and simple continuous blood pressure and cardiac output monitoring based on finger arterial pressure pulse contour analysis. We therefore investigated whether noninvasive continuous arterial blood pressure measurements using the ClearSight system were comparable to those obtained invasively in patients undergoing RALRP. Ten patients scheduled for RALRP with American Society of Anesthesiologists physical status I-II were included in this study. At each of the seven defined time points, noninvasive and invasive blood pressure measurements were documented and compared in each patient using Bland-Altman analysis. Although the blood pressure measured with the ClearSight system correlated with that measured invasively, a large difference between the values obtained by the two devices was noted. The ClearSight system was unable to detect blood pressure accurately during RALRP, suggesting that blood pressure monitoring using this device alone is not feasible in this small patient population. J. Med. Invest. 65:69-73, February, 2018.

  10. Intraoperative frozen pathology during robot-assisted laparoscopic radical prostatectomy: can ALEXIS™ trocar make it easy and fast?

    Science.gov (United States)

    Almeida, Gilberto Laurino; Musi, Gennaro; Mazzoleni, Federica; Matei, Deliu Victor; Brescia, Antonio; Detti, Serena; de Cobelli, Ottavio

    2013-10-01

    To describe the first series of robot-assisted laparoscopic radical prostatectomy (RALP) using the ALEXIS™ trocar device when removal of the specimen is necessary for intraoperative frozen-section pathology. Consecutive RALP using the ALEXIS were prospectively catalogue. Perioperative data, including preoperative oncologic diagnosis, operative time, estimated blood loss (EBL), size of incision for umbilical trocar, complications related to trocar, and length of hospital stay, were analyzed. One hundred twenty-eight patients were analyzed. The mean operative time was 216 minutes, mean time to trocar placement was 4 minutes, and mean EBL was 172 mL. The incision size for a trocar was 2-3 cm in 117 patients and 1 incisional hernia was observed. The mean hospital stay was 3 days and mean follow-up was 4 months. The ALEXIS trocar provides an easy and fast intraoperative removal of the specimen for frozen pathology during RALP, even for large prostates. Safe and cosmetic results with a low intraoperative complication rate are acquired with the wound retractor.

  11. Health-related quality of life after robotic-assisted laparoscopic hysterectomy for women with endometrial cancer

    DEFF Research Database (Denmark)

    Herling, Suzanne Forsyth; Møller, Ann M; Palle, Connie

    2016-01-01

    OBJECTIVE: The aim of this prospective cohort study using patient-reported outcome measures (PROMs) was to detect short term changes in functioning, symptoms and health-related quality of life (HRQoL) after robotic-assisted laparoscopic hysterectomy (RALH) for endometrial cancer or atypical compl......, gastrointestinal symptoms, appetite, ability to perform work and hobbies, change of taste and sexually related problems should be addressed in future research and in the pre- and postoperative care for women undergoing RALH....... postoperatively, but back to baseline level at 5 weeks. Ability to perform work or hobbies and change of taste were still affected at 5 weeks. CONCLUSIONS: HRQoL and postoperative symptoms were overall back to the preoperative level 5 weeks after RALH. These findings indicate fatigue, pain, constipation...... hyperplasia. METHODS/MATERIALS: A total of 139 women answered the EORTC C-30, EN-24 and EQ-5D-3L preoperatively (baseline) by face to face interview and again 1 week, 5 weeks and 4 months postoperatively by telephone interview. The women furthermore reported their level of activity compared to their habitual...

  12. Automatic Multiple-Needle Surgical Planning of Robotic-Assisted Microwave Coagulation in Large Liver Tumor Therapy.

    Directory of Open Access Journals (Sweden)

    Shaoli Liu

    Full Text Available The "robotic-assisted liver tumor coagulation therapy" (RALTCT system is a promising candidate for large liver tumor treatment in terms of accuracy and speed. A prerequisite for effective therapy is accurate surgical planning. However, it is difficult for the surgeon to perform surgical planning manually due to the difficulties associated with robot-assisted large liver tumor therapy. These main difficulties include the following aspects: (1 multiple needles are needed to destroy the entire tumor, (2 the insertion trajectories of the needles should avoid the ribs, blood vessels, and other tissues and organs in the abdominal cavity, (3 the placement of multiple needles should avoid interference with each other, (4 an inserted needle will cause some deformation of liver, which will result in changes in subsequently inserted needles' operating environment, and (5 the multiple needle-insertion trajectories should be consistent with the needle-driven robot's movement characteristics. Thus, an effective multiple-needle surgical planning procedure is needed. To overcome these problems, we present an automatic multiple-needle surgical planning of optimal insertion trajectories to the targets, based on a mathematical description of all relevant structure surfaces. The method determines the analytical expression of boundaries of every needle "collision-free reachable workspace" (CFRW, which are the feasible insertion zones based on several constraints. Then, the optimal needle insertion trajectory within the optimization criteria will be chosen in the needle CFRW automatically. Also, the results can be visualized with our navigation system. In the simulation experiment, three needle-insertion trajectories were obtained successfully. In the in vitro experiment, the robot successfully achieved insertion of multiple needles. The proposed automatic multiple-needle surgical planning can improve the efficiency and safety of robot-assisted large liver tumor

  13. Automatic Multiple-Needle Surgical Planning of Robotic-Assisted Microwave Coagulation in Large Liver Tumor Therapy.

    Science.gov (United States)

    Liu, Shaoli; Xia, Zeyang; Liu, Jianhua; Xu, Jing; Ren, He; Lu, Tong; Yang, Xiangdong

    2016-01-01

    The "robotic-assisted liver tumor coagulation therapy" (RALTCT) system is a promising candidate for large liver tumor treatment in terms of accuracy and speed. A prerequisite for effective therapy is accurate surgical planning. However, it is difficult for the surgeon to perform surgical planning manually due to the difficulties associated with robot-assisted large liver tumor therapy. These main difficulties include the following aspects: (1) multiple needles are needed to destroy the entire tumor, (2) the insertion trajectories of the needles should avoid the ribs, blood vessels, and other tissues and organs in the abdominal cavity, (3) the placement of multiple needles should avoid interference with each other, (4) an inserted needle will cause some deformation of liver, which will result in changes in subsequently inserted needles' operating environment, and (5) the multiple needle-insertion trajectories should be consistent with the needle-driven robot's movement characteristics. Thus, an effective multiple-needle surgical planning procedure is needed. To overcome these problems, we present an automatic multiple-needle surgical planning of optimal insertion trajectories to the targets, based on a mathematical description of all relevant structure surfaces. The method determines the analytical expression of boundaries of every needle "collision-free reachable workspace" (CFRW), which are the feasible insertion zones based on several constraints. Then, the optimal needle insertion trajectory within the optimization criteria will be chosen in the needle CFRW automatically. Also, the results can be visualized with our navigation system. In the simulation experiment, three needle-insertion trajectories were obtained successfully. In the in vitro experiment, the robot successfully achieved insertion of multiple needles. The proposed automatic multiple-needle surgical planning can improve the efficiency and safety of robot-assisted large liver tumor therapy

  14. [Robotic assisted laparoscopic living donor nephrectomy: preoperative assessment and results of 100 cases].

    Science.gov (United States)

    Laplace, B; Ladrière, M; Claudon, M; Eschwege, P; Kessler, M; Hubert, J

    2014-04-01

    To assess short term morbidity and renal function after robotic laparoscopic living donor nephrectomy. We performed a retrospective analysis of 100 consecutives patients undergoing a robotic laparoscopic living donors nephrectomy. We analyzed isotopic measure of the renal function before and 4 months after surgery, the side, the number of arteries, the blood loss, the operative time and warm ischemia time. In the outcomes, we collected the complications, the length of stay, and for the receiver, the renal function recovery time, dialysis, survival and renal function at one year. Left kidney nephrectomy was performed in 85 patients and we observed 25 multiples renal arteries. Mean estimated blood loss was 0,8 g/dL. Mean operative time and warm ischemia time were respectively 174 ± 30 and 4.8 ± 1.7 minutes. Seven complications occured, with 2 major (Clavien-Dindo System). Mean length of stay was 5.1 ± 1.9 days. Mean glomerular filtration decrease was 26% and remains stable at one year after surgery. Grafts had an immediate renal function recovery for 99%, and were all functional after one year, with mean MDRD clearance of 57 ± 14mL/min. Robotic procedure in laparoscopic living donor nephrectomy seems to guarantee low morbidity and the stability of the renal function decrease of 26%. Copyright © 2013. Published by Elsevier Masson SAS.

  15. Comparative biomarker expression and RNA integrity in biospecimens derived from radical retropubic and robot-assisted laparoscopic prostatectomies.

    Science.gov (United States)

    Ricciardelli, Carmela; Bianco-Miotto, Tina; Jindal, Shalini; Dodd, Thomas J; Cohen, Penelope A; Marshall, Villis R; Sutherland, Peter D; Samaratunga, Hemamali; Kench, James G; Dong, Ying; Wang, Hong; Clements, Judith A; Risbridger, Gail P; Sutherland, Robert L; Tilley, Wayne D; Horsfall, David J

    2010-07-01

    Knowledge of preanalytic conditions that biospecimens are subjected to is critically important because novel surgical procedures, tissue sampling, handling, and storage might affect biomarker expression or invalidate tissue samples as analytes for some technologies. We investigated differences in RNA quality, gene expression by quantitative real-time PCR, and immunoreactive protein expression of selected prostate cancer biomarkers between tissues from retropubic radical prostatectomy (RRP) and robot-assisted laparoscopic prostatectomy (RALP). Sections of tissue microarray of 23 RALP and 22 RRP samples were stained with antibodies to androgen receptor (AR) and prostate-specific antigen (PSA) as intersite controls, and 14 other candidate biomarkers of research interest to three laboratories within the Australian Prostate Cancer BioResource tissue banking network. Quantitative real-time PCR was done for AR, PSA (KLK3), KLK2, KLK4, and HIF1A on RNA extracted from five RALP and five RRP frozen tissue cores. No histologic differences were observed between RALP and RRP tissue. Biomarker staining grouped these samples into those with increased (PSA, CK8/18, CKHMW, KLK4), decreased (KLK2, KLK14), or no change in expression (AR, ghrelin, Ki67, PCNA, VEGF-C, PAR2, YB1, p63, versican, and chondroitin 0-sulfate) in RALP compared with RRP tissue. No difference in RNA quality or gene expression was detected between RALP and RRP tissue. Changes in biomarker expression between RALP and RRP tissue exist at the immunoreactive protein level, but the etiology is unclear. Future studies should account for changes in biomarker expression when using RALP tissues, and mixed cohorts of RALP and RRP tissue should be avoided.

  16. Robot-assisted radical prostatectomy has lower biochemical recurrence than laparoscopic radical prostatectomy: Systematic review and meta-analysis

    Directory of Open Access Journals (Sweden)

    Seon Heui Lee

    2017-05-01

    Full Text Available Purpose: To assess the effectiveness and safety of robot-assisted radical prostatectomy (RARP versus laparoscopic radical prostatectomy (LRP in the treatment of prostate cancer. Materials and Methods: Existing systematic reviews were updated to investigate the effectiveness and safety of RARP. Electronic databases, including Ovid MEDLINE, Ovid Embase, the Cochrane Library, KoreaMed, Kmbase, and others, were searched through July 2014. The quality of the selected systematic reviews was assessed by using the revised assessment of multiple systematic reviews (R-Amstar and the Cochrane Risk of Bias tool. Meta-analysis was performed by using Revman 5.2 (Cochrane Community and Comprehensive Meta-Analysis 2.0 (CMA; Biostat. Cochrane Q and I2 statistics were used to assess heterogeneity. Results: Two systematic reviews and 16 additional studies were selected from a search performed of existing systematic reviews. These included 2 randomized controlled clinical trials and 28 nonrandomized comparative studies. The risk of complications, such as injury to organs by the Clavien-Dindo classification, was lower with RARP than with LRP (relative risk [RR], 0.44; 95% confidence interval [CI], 1.23–0.85; p=0.01. The risk of urinary incontinence was lower (RR, 0.43; 95% CI, 0.31–0.60; p<0.000001 and the potency rate was significantly higher with RARP than with LRP (RR, 1.38; 95% CI, 1.11–1.70; I2 =78%; p=0.003. Regarding positive surgical margins, no significant difference in risk between the 2 groups was observed; however, the biochemical recurrence rate was lower after RARP than after LRP (RR, 0.59; 95% CI, 0.48–0.73; I2 =21%; p<0.00001. Conclusions: RARP appears to be a safe and effective technique compared with LRP with a lower complication rate, better potency, a higher continence rate, and a decreased rate of biochemical recurrence.

  17. Impact of tamsulosin on urinary retention following early catheter removal after robot-assisted laparoscopic radical prostatectomy: a prospective randomized controlled trial.

    Science.gov (United States)

    Jeong, In Gab; You, Dalsan; Yoon, Jong Hyun; Hong, Sungwoo; Lim, Ju Hyun; Hong, Jun Hyuk; Choo, Myung-Soo; Ahn, Hanjong; Kim, Choung-Soo

    2014-02-01

    To examine the impact of tamsulosin on the rate of acute urinary retention following early catheter removal after robot-assisted laparoscopic radical prostatectomy. A total of 236 patients who underwent robot-assisted laparoscopic radical prostatectomy for prostate cancer carried out by a single surgeon were enrolled in this randomized study. Patients were randomly divided into two groups: treatment with tamsulosin (0.4 mg) from 1 day before to 14 days after surgery (tamsulosin group), or no tamsulosin treatment (control group). The urethral catheter was removed on the fifth postoperative day. The primary end-point was the acute urinary retention rate. Changes in each domain of the International Continence Society male short-form questionnaire and uroflowmetry parameters were secondary end-points. The primary end-point was assessed in 218 patients (92.4%; n = 109 in each group). It was not assessed in 18 patients because of cystographic leak from the vesicourethral anastomosis. The acute urinary retention rate was lower in the tamsulosin group (7.3%) than in the control group (17.4%, P = 0.018). Multivariate logistic regression analysis identified tamsulosin treatment and the operative experience of the surgeon as independent risk factors for acute urinary retention. Tamsulosin-treated patients had a 0.30-fold lower risk of developing acute urinary retention compared with control patients (95% confidence interval 0.12-0.76; P = 0.011). None of the International Continence Society male questionnaire domain scores showed significant changes between the groups. Perioperative treatment with tamsulosin in patients undergoing robot-assisted laparoscopic radical prostatectomy reduces the rate of acute urinary retention after early catheter removal, without aggravating urinary incontinence. © 2013 The Japanese Urological Association.

  18. Comparison of robot-assisted versus conventional laparoscopic transperitoneal pyeloplasty for patients with ureteropelvic junction obstruction: a single-center study.

    Science.gov (United States)

    Bird, Vincent G; Leveillee, Raymond J; Eldefrawy, Ahmed; Bracho, Jorge; Aziz, Mohammed S

    2011-03-01

    To compare conventional laparoscopic pyeloplasty (C-LPP) and robotic-assisted laparoscopic pyeloplasty (RA-LPP), which are both used for correction of ureteropelvic junction obstruction. Robotic assistance may further expedite dissection and reconstruction; however it is unclear whether this has an impact on results. Between 1999 and 2009, 172 conventional or robotic-assisted transperitoneal laparoscopic pyeloplasties were performed by 2 surgeons. Data were obtained from our prospective database, patient charts, and radiographic reports. Statistical analysis was performed for the groups. A total of 98 patients underwent R-LPP, and 74 underwent C-LPP. Mean age, body mass index, and gender distribution were similar for the groups. Of the patients, 22 (12.8%) had secondary ureteropelvic junction obstruction. Operative time in minutes was 189.3 ± 62 for RA-LPP, and 186.6 ± 69 for C-LPP (P = .69) respectively. Intraoperative and postoperative complication rates for RA-LPP and C-LPP were 1%, 5.1% and 0, 2.7% (P = .83 and .85) respectively. There was no significant difference in mean suturing time: 48.3 ± 30 and 60 ± 46 (P = .30) for RA-LPP and C-LPP, respectively. Long-term follow up (minimum 6 months; available for 136 patients) showed 93.4% and 95% radiographic success rate based upon diuretic scintirenography for RA-LPP and C-LPP respectively. Operative time, perioperative outcome and success rates are similar for C-LPP and RA-LPP. Mean suturing time for RA-LPP was shorter; however, there was no significant time difference in total operative time. Complications for both procedures are infrequent. Success rates, as measured by diuretic scintirenography, are high for the 2 procedures. Copyright © 2011 Elsevier Inc. All rights reserved.

  19. Spontaneous Retroperitoneal Hemorrhage (Wunderlich Syndrome due to Large Upper Pole Renal Angiomyolipoma: Does Robotic-Assisted Laparoscopic Partial Nephrectomy Have a Role in Primary Treatment?

    Directory of Open Access Journals (Sweden)

    Achilles Ploumidis

    2013-01-01

    Full Text Available Spontaneous rapture with consequent retroperitoneal hemorrhage (Wunderlich’s syndrome is the complication mostly feared from large renal angiomyolipomas (RAMLs. In hemodynamic stable patients, minimal invasive therapies have superseded open surgery as the mainstay of treatment, with contemporary cases mostly treated by selective arterial embolization. Robotic-assisted laparoscopic partial nephrectomy (RALPN is an established minimal access treatment that has been used in the past for benign and malignant lesions of the kidney in the elective setting, but rarely in urgent situations as primary treatment. We present a case of a ruptured RAML in a young female treated effectively by RALPN.

  20. A comparative study of erectile function and use of erectile aids in high-risk prostate cancer patients after robot-assisted laparoscopic prostatectomy

    DEFF Research Database (Denmark)

    Østby-Deglum, Marie; Brennhovd, B.; Axcrona, K.

    2015-01-01

    Objective. Erectile function with and without use of erectile aids was compared in high-, intermediate- and low-risk prostate cancer patients at a mean of 3 years after robot-assisted laparoscopic prostatectomy (RALP). Materials and methods. A sample of 982 men who underwent RALP at Oslo University...... according to the preoperative D'Amico classification. Based on questionnaire data, two primary outcomes were defined: ability to have intercourse (sufficient erection), and use and effect of erectile aids. Results. Sufficient erection with or without erectile aids was reported by 19% of the high-, 30...

  1. Effect of Robotic-Assisted vs Conventional Laparoscopic Surgery on Risk of Conversion to Open Laparotomy Among Patients Undergoing Resection for Rectal Cancer

    Science.gov (United States)

    Pigazzi, Alessio; Marshall, Helen; Croft, Julie; Corrigan, Neil; Copeland, Joanne; Quirke, Phil; West, Nick; Rautio, Tero; Thomassen, Niels; Tilney, Henry; Gudgeon, Mark; Bianchi, Paolo Pietro; Edlin, Richard; Hulme, Claire; Brown, Julia

    2017-01-01

    Importance Robotic rectal cancer surgery is gaining popularity, but limited data are available regarding safety and efficacy. Objective To compare robotic-assisted vs conventional laparoscopic surgery for risk of conversion to open laparotomy among patients undergoing resection for rectal cancer. Design, Setting, and Participants Randomized clinical trial comparing robotic-assisted vs conventional laparoscopic surgery among 471 patients with rectal adenocarcinoma suitable for curative resection conducted at 29 sites across 10 countries, including 40 surgeons. Recruitment of patients was from January 7, 2011, to September 30, 2014, follow-up was conducted at 30 days and 6 months, and final follow-up was on June 16, 2015. Interventions Patients were randomized to robotic-assisted (n = 237) or conventional (n = 234) laparoscopic rectal cancer resection, performed by either high (upper rectum) or low (total rectum) anterior resection or abdominoperineal resection (rectum and perineum). Main Outcomes and Measures The primary outcome was conversion to open laparotomy. Secondary end points included intraoperative and postoperative complications, circumferential resection margin positivity (CRM+) and other pathological outcomes, quality of life (36-Item Short Form Survey and 20-item Multidimensional Fatigue Inventory), bladder and sexual dysfunction (International Prostate Symptom Score, International Index of Erectile Function, and Female Sexual Function Index), and oncological outcomes. Results Among 471 randomized patients (mean [SD] age, 64.9 [11.0] years; 320 [67.9%] men), 466 (98.9%) completed the study. The overall rate of conversion to open laparotomy was 10.1%: 19 of 236 patients (8.1%) in the robotic-assisted laparoscopic group and 28 of 230 patients (12.2%) in the conventional laparoscopic group (unadjusted risk difference = 4.1% [95% CI, −1.4% to 9.6%]; adjusted odds ratio = 0.61 [95% CI, 0.31 to 1.21]; P = .16). The overall CRM+ rate was

  2. Oncological outcomes of high-risk prostate cancer patients between robot-assisted laparoscopic radical prostatectomy and laparoscopic radical prostatectomy in Taiwan

    Directory of Open Access Journals (Sweden)

    Chieh-Chun Liao

    2018-01-01

    Full Text Available Objective: To compare pathological and oncological outcomes between robotic-assisted laparoscopic radical prostatectomy (RaLRP and laparoscopic radical prostatectomy (LRP among high-risk prostate cancer patient in a tertiary center in Taiwan. Materials and methods: From November 2003 to October 2013, 129 high-risk prostate cancer patients receiving minimally-invasive radical prostatectomy were included. The Kaplan–Meier analysis was used for measuring biochemical recurrence-free survival (BFS. Multivariate logistic regression models and Cox proportional hazards regression models were used to determine predictors of positive surgical margin and BFS. Results: Among the 129 high-risk prostate cancer patients included, 80 (62% patients received LRP and 49 (38% patients received RaLRP. There was no significant difference of positive surgical margin and biochemical recurrence rate between RaLRP and LRP group (P = 0.802 and 0.292. Higher pathological T stage predicted an increased likelihood of positive margins (OR = 3.44, 95% CI [1.45, 8.18], P = 0.005. Higher initial PSA level (HR = 2.88, 95% CI [1.04, 7.94], P = 0.041 and positive surgical margin (HR = 2.55, 95% CI [1.20, 5.44], P = 0.015 were poor prognostic factors for BFS. Conclusion: RaLRP can be considered among high-risk prostate cancer in Asian people with comparable oncological outcomes to LRP. Higher pathological T stage was associated with increased likelihood of positive margins, patients with higher iPSA level and positive surgical margin had worsen biochemical recurrence-free survival.

  3. [Robot-assisted pancreatic resection].

    Science.gov (United States)

    Müssle, B; Distler, M; Weitz, J; Welsch, T

    2017-06-01

    Although robot-assisted pancreatic surgery has been considered critically in the past, it is nowadays an established standard technique in some centers, for distal pancreatectomy and pancreatic head resection. Compared with the laparoscopic approach, the use of robot-assisted surgery seems to be advantageous for acquiring the skills for pancreatic, bile duct and vascular anastomoses during pancreatic head resection and total pancreatectomy. On the other hand, the use of the robot is associated with increased costs and only highly effective and professional robotic programs in centers for pancreatic surgery will achieve top surgical and oncological quality, acceptable operation times and a reduction in duration of hospital stay. Moreover, new technologies, such as intraoperative fluorescence guidance and augmented reality will define additional indications for robot-assisted pancreatic surgery.

  4. Augmented reality during robot-assisted laparoscopic partial nephrectomy: toward real-time 3D-CT to stereoscopic video registration.

    Science.gov (United States)

    Su, Li-Ming; Vagvolgyi, Balazs P; Agarwal, Rahul; Reiley, Carol E; Taylor, Russell H; Hager, Gregory D

    2009-04-01

    To investigate a markerless tracking system for real-time stereo-endoscopic visualization of preoperative computed tomographic imaging as an augmented display during robot-assisted laparoscopic partial nephrectomy. Stereoscopic video segments of a patient undergoing robot-assisted laparoscopic partial nephrectomy for tumor and another for a partial staghorn renal calculus were processed to evaluate the performance of a three-dimensional (3D)-to-3D registration algorithm. After both cases, we registered a segment of the video recording to the corresponding preoperative 3D-computed tomography image. After calibrating the camera and overlay, 3D-to-3D registration was created between the model and the surgical recording using a modified iterative closest point technique. Image-based tracking technology tracked selected fixed points on the kidney surface to augment the image-to-model registration. Our investigation has demonstrated that we can identify and track the kidney surface in real time when applied to intraoperative video recordings and overlay the 3D models of the kidney, tumor (or stone), and collecting system semitransparently. Using a basic computer research platform, we achieved an update rate of 10 Hz and an overlay latency of 4 frames. The accuracy of the 3D registration was 1 mm. Augmented reality overlay of reconstructed 3D-computed tomography images onto real-time stereo video footage is possible using iterative closest point and image-based surface tracking technology that does not use external navigation tracking systems or preplaced surface markers. Additional studies are needed to assess the precision and to achieve fully automated registration and display for intraoperative use.

  5. Limited Evidence for Robot-assisted Surgery

    DEFF Research Database (Denmark)

    Broholm, Malene; Onsberg Hansen, Iben; Rosenberg, Jacob

    2016-01-01

    -assisted surgery. Open versus robot-assisted surgery was investigated in 3 studies. A lower blood loss and a longer operative time were found after robot-assisted surgery. No other difference was detected. CONCLUSIONS: At this point there is not enough evidence to support the significantly higher costs......PURPOSE: To evaluate available evidence on robot-assisted surgery compared with open and laparoscopic surgery. METHOD: The databases Medline, Embase, and Cochrane Library were systematically searched for randomized controlled trials comparing robot-assisted surgery with open and laparoscopic...... surgery regardless of surgical procedure. Meta-analyses were performed on each outcome with appropriate data material available. Cochrane Collaboration's tool for assessing risk of bias was used to evaluate risk of bias on a study level. The GRADE approach was used to evaluate the quality of evidence...

  6. Laparoscopic liver resection assisted by the laparoscopic Habib Sealer.

    Science.gov (United States)

    Jiao, Long R; Ayav, Ahmet; Navarra, Giuseppe; Sommerville, Craig; Pai, Madhava; Damrah, Osama; Khorsandi, Shrin; Habib, Nagy A

    2008-11-01

    Radiofrequency has been used as a tool for liver resection since 2002. A new laparoscopic device is reported in this article that assists liver resection laparoscopically. From October 2006 to the present, patients suitable for liver resection were assessed carefully for laparoscopic resection with the laparoscopic Habib Sealer (LHS). Detailed data of patients resected laparoscopically with this device were collected prospectively and analyzed. In all, 28 patients underwent attempted laparoscopic liver resection. Four cases had to be converted to an open approach because of extensive adhesions from previous colonic operations. Twenty-four patients completed the procedure comprising tumorectomy (n = 7), multiple tumoretcomies (n = 5), segmentectomy (n = 3), and bisegmentectomies (n = 9). Vascular clamping of portal triads was not used. The mean resection time was 60 +/- 23 min (mean +/- SD), and blood loss was 48 +/- 54 mL. None of the patients received any transfusion of blood or blood products perioperatively or postoperatively. Postoperatively, 1 patient developed severe exacerbation of asthma that required steroid therapy, and 1 other patient had a transient episode of liver failure that required supportive care. The mean duration of hospital stay was 5.6 +/- 2 days (mean +/- SD). At a short-term follow up, no recurrence was detected in patients with liver cancer. Laparoscopic liver resection can be performed safely with this new laparoscopic liver resection device with a significantly low risk of intraoperative bleeding or postoperative complications.

  7. [Robot-Assisted Laparoscopic Radical Prostatectomy for Patients with Prostatic Cancer and Factors Promoting Installation of the Robotic Surgical Equipment-Questionnaire Survey].

    Science.gov (United States)

    Tsukamoto, Taiji; Tanaka, Shigeru

    2015-08-01

    We conducted a questionnaire survey of hospitals with robot-assisted surgical equipment to study changes of the surgical case loads after its installation and the managerial strategies for its purchase. The study included 154 hospitals (as of April 2014) that were queried about their radical prostatectomy case loads from January 2009 to December 2013, strategies for installation of the equipment in their hospitals, and other topics related to the study purpose. The overall response rate of hospitals was 63%, though it marginally varied according to type and area. The annual case load was determined based on the results of the questionnaire and other modalities. It increased from 3,518 in 2009 to 6,425 in 2013. The case load seemed to be concentrated in hospitals with robot equipment since the increase of their number was very minimal over the 5 years. The hospitals with the robot treated a larger number of newly diagnosed patients with the disease than before. Most of the patients were those having localized cancer that was indicated for radical surgery, suggesting again the concentration of the surgical case loads in the hospitals with robots. While most hospitals believed that installation of a robot was necessary as an option for treatment procedures, the future strategy of the hospital, and other reasons, the action of the hospital to gain prestige may be involved in the process of purchasing the equipment. In conclusion, robot-assisted laparoscopic radical prostatectomy has become popular as a surgical procedure for prostate cancer in our society. This may lead to a concentration of the surgical case load in a limited number of hospitals with robots. We also discuss the typical action of an acute-care hospital when it purchases expensive clinical medical equipment.

  8. Robotically Assisted Sonic Therapy as a Noninvasive Nonthermal Ablation Modality: Proof of Concept in a Porcine Liver Model.

    Science.gov (United States)

    Smolock, Amanda R; Cristescu, Mircea M; Vlaisavljevich, Eli; Gendron-Fitzpatrick, Annette; Green, Chelsey; Cannata, Jonathan; Ziemlewicz, Timothy J; Lee, Fred T

    2018-05-01

    Purpose To determine the feasibility of creating a clinically relevant hepatic ablation (ie, an ablation zone capable of treating a 2-cm liver tumor) by using robotically assisted sonic therapy (RAST), a noninvasive and nonthermal focused ultrasound therapy based on histotripsy. Materials and Methods This study was approved by the institutional animal use and care committee. Ten female pigs were treated with RAST in a single session with a prescribed 3-cm spherical treatment region and immediately underwent abdominal magnetic resonance (MR) imaging. Three pigs (acute group) were sacrificed immediately following MR imaging. Seven pigs (chronic group) were survived for approximately 4 weeks and were reimaged with MR imaging immediately before sacrifice. Animals underwent necropsy and harvesting of the liver for histologic evaluation of the ablation zone. RAST ablations were performed with a 700-kHz therapy transducer. Student t tests were performed to compare prescribed versus achieved ablation diameter, difference of sphericity from 1, and change in ablation zone volume from acute to chronic imaging. Results Ablation zones had a sphericity index of 0.99 ± 0.01 (standard deviation) (P < .001 vs sphericity index of 1). Anteroposterior and transverse dimensions were not significantly different from prescribed (3.4 ± 0.7; P = .08 and 3.2 ± 0.8; P = .29, respectively). The craniocaudal dimension was significantly larger than prescribed (3.8 ± 1.1; P = .04), likely because of respiratory motion. The central ablation zone demonstrated complete cell destruction and a zone of partial necrosis. A fibrous capsule surrounded the ablation zone by 4 weeks. On 4-week follow-up images, ablation zone volumes decreased by 64% (P < .001). Conclusion RAST is capable of producing clinically relevant ablation zones in a noninvasive manner in a porcine model. © RSNA, 2018.

  9. First year experience of robotic-assisted laparoscopic surgery with 153 cases in a general surgery department: indications, technique and results.

    Science.gov (United States)

    Tomulescu, V; Stănciulea, O; Bălescu, I; Vasile, S; Tudor, St; Gheorghe, C; Vasilescu, C; Popescu, I

    2009-01-01

    Robotic surgery was developed in response to the limitations and drawbacks of laparoscopic surgery. Since 1997 when the first robotic procedure was performed various papers pointed the advantages of robotic-assisted laparoscopic surgery, this technique is now a reality and it will probably become the surgery of the future. The aim of this paper is to present our preliminary experience with the three-arms "da Vinci S surgical system", to assess the feasibility of this technique in various abdominal and thoracic procedures and to point out the advantages of the robotic approach for each type of procedure. Between 18 January 2008 and 18 January 2009 153 patients (66 men and 87 women; mean age 48,02 years, range 6 to 84 years) underwent robotic-assisted surgical procedures in our institution; we performed 129 abdominal and 24 thoracic procedures, as follows: one cholecystectomy, 14 myotomies with Dor fundoplication, one gastroenteroanastomosis for unresectable antral gastric cancer, one transthoracic esophagectomy, 14 gastrectomies, one polypectomy through gastrotomy, 22 splenectomies,7 partial spleen resections, 22 thymectomy, 6 Nissen fundoplications, one Toupet fundoplication, one choledocho-duodeno-anastomosis, one drainage for pancreatic abscess, one distal pancreatectomy, one hepatic cyst fenestration, 7 hepatic resections, 29 colonic and rectal resections, 5 adrenalectomies, 12 total radical hysterectomies and pelvic lymphadenectomy, 3 hysterectomies with bilateral adnexectomy for uterine fibroma, one unilateral adnexectomy, and 2 cases of cervico-mediastinal goitre resection. 147 procedures were robotics completed , whereas 6 procedures were converted to open surgery due to the extent of the lesion. Average operating room time was 171 minutes (range 60 to 600 minutes, Median length of stay was 8,6 days (range 2 to 48 days). One system malfunctions was registered. Post-operatory complications occurred in 14 cases. There were no deaths. Our preliminary experience

  10. Short-term results of changes in existing and de novo lower urinary tract symptoms after robot-assisted laparoscopic uterosacral ligament suspension and sacrocolpopexy.

    Science.gov (United States)

    Kurdoglu, Mertihan; Unlu, Serdar; Antonetti-Elford, Megan; Kurdoglu, Zehra; Kilic, Gokhan S

    2018-03-06

    This study presents short-term outcomes related to changes in existing and de novo lower urinary tract symptoms (LUTS), pelvic pain, and bowel function following robot-assisted laparoscopic uterosacral ligament suspension (RALUSLS) and sacrocolpopexy (RALSC). Observational data for RALUSLS (n = 23) and RALSC (n = 25) collected between August 2014 and March 2016 from a single institute (The University of Texas Medical Branch) were evaluated retrospectively. Patient characteristics, concomitant procedures, and the occurrence of lower urinary tract, pelvic pain, and bowel symptoms were compared between patients undergoing RALUSLS and RALSC. There was no significant difference in background characteristics between the 2 groups, except for parity, which was high in the RALUSLS group. In the RALUSLS group, patients experienced significant resolution of urinary urgency (P .05), although newly appearing urinary urgency or frequency and stress or urge incontinence were more common after RALSC. Mixed incontinence and pelvic pain improved significantly in patients after RALUSLS or RALSC. In RALUSLS patients, urgency, frequency, and urge incontinence also improved, whereas additional improvement in nocturia and dyspareunia was evident only in RALSC patients. De novo LUTS developing after these procedures, especially after RALSC, necessitate careful patient consultation prior to surgery. © 2018 John Wiley & Sons Australia, Ltd.

  11. Robot-assisted laparoscopic pyeloureterostomy in infants with duplex systems and upper pole hydronephrosis: Variations in double-J ureteral stenting techniques.

    Science.gov (United States)

    Baek, Minki; Au, Jason; Huang, Gene O; Koh, Chester J

    2017-04-01

    We describe our experience with robot-assisted laparoscopic (RAL) pyeloureterostomy in infants with duplex systems and upper pole hydronephrosis with an emphasis on the various double J (DJ) ureteral stent placement techniques. We used our RAL pyeloureterostomy technique in two female infants with duplex systems and upper pole hydronephrosis. For case 1, we introduced the DJ stent and placed it in the recipient lower pole ureter during the robotic operation in an antegrade fashion. For case 2, we inserted the DJ stent during retrograde pyelography prior to the robotic procedure in a retrograde fashion, and the proximal portion of the stent was placed across the anastomosis into the upper pole renal pelvis. Postoperatively, each of the patients were discharged on postoperative day 1 without complications. The postoperative renal ultrasound at 3 months demonstrated marked improvement of the right upper pole hydronephrosis in both patients. RAL pyeloureterostomy represents a minimally invasive option for upper tract reconstruction of duplex systems with upper pole hydronephrosis in infants. The DJ stent can be placed at the beginning or during the procedure. The stent can be placed in the lower pole ureter or across the anastomosis into the upper pole renal pelvis. Copyright © 2017 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  12. Commentary on "a matched comparison of perioperative outcomes of a single laparoscopic surgeon versus a multisurgeon robot-assisted cohort for partial nephrectomy." Ellison JS, Montgomery JS, Wolf Jr JS, Hafez KS, Miller DC, Weizer AZ, Department of Urology, University of Michigan, Ann Arbor, MI, USA: J Urol 2012;188(1):45-50.

    Science.gov (United States)

    Kane, Christopher

    2013-02-01

    Minimally invasive nephron sparing surgery is gaining popularity for small renal masses. Few groups have evaluated robot-assisted partial nephrectomy compared to other approaches using comparable patient populations. We present a matched pair analysis of a heterogeneous group of surgeons who performed robot-assisted partial nephrectomy and a single experienced laparoscopic surgeon who performed conventional laparoscopic partial nephrectomy. Perioperative outcomes and complications were compared. All 249 conventional laparoscopic and robot-assisted partial nephrectomy cases from January 2007 to June 2010 were reviewed from our prospectively maintained institutional database. Groups were matched 1:1 (108 matched pairs) by R.E.N.A.L. (radius, exophytic/endophytic properties, nearness of tumor to collecting system or sinus, anterior/posterior, location relative to polar lines) nephrometry score, transperitoneal vs retroperitoneal approach, patient age and hilar nature of the tumor. Statistical analysis was done to compare operative outcomes and complications. Matched analysis revealed that nephrometry score, age, gender, tumor side and American Society of Anesthesia physical status classification were similar. Operative time favored conventional laparoscopic partial nephrectomy. During the study period robot-assisted partial nephrectomy showed significant improvements in estimated blood loss and warm ischemia time compared to those of the experienced conventional laparoscopic group. Postoperative complication rates, and complication distributions by Clavien classification and type were similar for conventional laparoscopic and robot-assisted partial nephrectomy (41.7% and 35.0%, respectively). Robot-assisted partial nephrectomy has a noticeable but rapid learning curve. After it is overcome the robotic procedure results in perioperative outcomes similar to those achieved with conventional laparoscopic partial nephrectomy done by an experienced surgeon. Robot-assisted

  13. A comparative cost analysis of robotic-assisted surgery versus laparoscopic surgery and open surgery: the necessity of investing knowledgeably.

    Science.gov (United States)

    Tedesco, Giorgia; Faggiano, Francesco C; Leo, Erica; Derrico, Pietro; Ritrovato, Matteo

    2016-11-01

    Robotic surgery has been proposed as a minimally invasive surgical technique with advantages for both surgeons and patients, but is associated with high costs (installation, use and maintenance). The Health Technology Assessment Unit of the Bambino Gesù Children's Hospital sought to investigate the economic sustainability of robotic surgery, having foreseen its impact on the hospital budget METHODS: Break-even and cost-minimization analyses were performed. A deterministic approach for sensitivity analysis was applied by varying the values of parameters between pre-defined ranges in different scenarios to see how the outcomes might differ. The break-even analysis indicated that at least 349 annual interventions would need to be carried out to reach the break-even point. The cost-minimization analysis showed that robotic surgery was the most expensive procedure among the considered alternatives (in terms of the contribution margin). Robotic surgery is a good clinical alternative to laparoscopic and open surgery (for many pediatric operations). However, the costs of robotic procedures are higher than the equivalent laparoscopic and open surgical interventions. Therefore, in the short run, these findings do not seem to support the decision to introduce a robotic system in our hospital.

  14. Endolymphatic Ethiodized Oil Intranodal Lymphangiography and Cyanoacrylate Glue Embolization for the Treatment of Postoperative Lymphatic Leak After Robot-Assisted Laparoscopic Pelvic Resection.

    Science.gov (United States)

    Hill, Hannah; Srinivasa, Ravi N; Gemmete, Joseph J; Hage, Anthony; Bundy, Jacob; Chick, Jeffrey Forris Beecham

    2018-01-01

    Purpose: To report the approach, technical success, clinical outcomes, complications, and follow-up of ethiodized oil intranodal lymphangiography with cyanoacrylate glue embolization for the treatment of lymphatic leak after robot-assisted laparoscopic pelvic resection. Materials and Methods: Four men with mean age 68.7 ± 14.3 years were treated with ethiodized oil intranodal lymphangiography with cyanoacrylate embolization for postoperative lymphatic leak. Patients underwent either (1) cystoprostatectomy with ileal conduit and bilateral extensive pelvic lymph node dissection for muscle-invasive urothelial carcinoma and presented with postoperative lymphatic ascites ( n  = 2) or (2) prostatectomy with bilateral standard pelvic lymph node dissection for prostate carcinoma and presented with postoperative pelvic lymphoceles ( n  = 2). Intranodal lymphangiography and embolization procedural details, technical success, clinical outcomes, and follow-up were recorded. Results: In four patients, a total of six ethiodized oil intranodal lymphangiograms were performed, two procedures being repeated interventions. Inguinal lymph node catheterization and ethiodized oil lymphangiography was technically effective in all procedures. A mean of 5.2 ± 2.0 mL of ethiodized oil was used for lymphatic opacification. Cyanoacrylate was diluted to 24.2% with ethiodized oil and 0.44 mL of cyanoacrylate was instilled during first time interventions. On repeat procedures, cyanoacrylate was diluted to 51.7%, and 0.52 mL was instilled. The primary clinical success rate was 50% ( n  = 2/4). Clinical success was achieved in all patients after two interventions ( n  = 4; 100%). No complications were reported at mean follow-up of 134.7 ± 79.2 days (range: 59-248 days). Conclusion: Ethiodized oil intranodal lymphangiography with direct cyanoacrylate glue embolization is a minimally invasive treatment option for lymphatic leak after pelvic resection.

  15. Retroperitoneal versus transperitoneal robotic-assisted laparoscopic partial nephrectomy: a matched-pair, bicenter analysis with cost comparison using time-driven activity-based costing.

    Science.gov (United States)

    Laviana, Aaron A; Tan, Hung-Jui; Hu, Jim C; Weizer, Alon Z; Chang, Sam S; Barocas, Daniel A

    2018-03-01

    To perform a bicenter, retrospective study of perioperative outcomes of retroperitoneal versus transperitoneal robotic-assisted laparoscopic partial nephrectomy (RALPN) and assess costs using time-driven activity-based costing (TDABC). We identified 355 consecutive patients who underwent RALPN at University of California Los Angeles and the University of Michigan during 2009-2016. We matched according to RENAL nephrometry score, date, and institution for 78 retroperitoneal versus 78 transperitoneal RALPN. Unadjusted analyses were performed using McNemar's Chi-squared or paired t test, and adjusted analyses were performed using multivariable repeated measures regression analysis. From multivariable models, predicted probabilities were derived according to approach. Cost analysis was performed using TDABC. Patients treated with retroperitoneal versus transperitoneal RALPN were similar in age (P = 0.490), sex (P = 0.715), BMI (P = 0.273), and comorbidity (P = 0.393). Most tumors were posterior or lateral in both the retroperitoneal (92.3%) and transperitoneal (85.9%) groups. Retroperitoneal RALPN was associated with shorter operative times (167.0 versus 191.1 min, P = 0.001) and length of stay (LOS) (1.8 versus 2.7 days, P factoring in disposable equipment, operative time, LOS, and personnel. In two high-volume, tertiary centers, retroperitoneal RALPN is associated with reduced operative times and shortened LOS in posterior and lateral tumors, whereas sharing similar clinicopathologic outcomes, which may translate into lower healthcare costs. Further investigation into anterior tumors is needed.

  16. Health-related quality of life from a prospective randomised clinical trial of robot-assisted laparoscopic vs open radical cystectomy.

    Science.gov (United States)

    Messer, Jamie C; Punnen, Sanoj; Fitzgerald, John; Svatek, Robert; Parekh, Dipen J

    2014-12-01

    To compare health-related quality-of-life (HRQoL) outcomes for robot-assisted laparoscopic radical cystectomy (RARC) with those of traditional open radical cystectomy (ORC) in a prospective randomised fashion. This was a prospective randomised clinical trial evaluating the HRQoL for ORC vs RARC in consecutive patients from July 2009 to June 2011. We administered the Functional Assessment of Cancer Therapy-Vanderbilt Cystectomy Index questionnaire, validated to assess HRQoL, preoperatively and then at 3, 6, 9 and 12 months postoperatively. Scores for each domain and total scores were compared in terms of deviation from preoperative values for both the RARC and the ORC cohorts. Multivariate linear regression was used to assess the association between the type of radical cystectomy and HRQoL. At the time of the study, 47 patients had met the inclusion criteria, with 40 patients being randomised for analysis. The cohorts consisted of 20 patients undergoing ORC and 20 undergoing RARC, who were balanced with respect to baseline demographic and clinical features. Univariate analysis showed a return to baseline scores at 3 months postoperatively in all measured domains with no statistically significant difference among the various domains between the RARC and the ORC cohorts. Multivariate analysis showed no difference in HRQoL between the two approaches in any of the various domains, with the exception of a slightly higher physical well-being score in the RARC group at 6 months. There were no significant differences in the HRQoL outcomes between ORC and RARC, with a return of quality of life scores to baseline scores 3 months after radical cystectomy in both cohorts. © 2014 The Authors. BJU International © 2014 BJU International.

  17. Early results after robot-assisted colorectal surgery

    DEFF Research Database (Denmark)

    Eriksen, Jens Ravn; Helvind, Neel Maria; Jakobsen, Henrik Loft

    2013-01-01

    Implementation of robotic technology in surgery is challenging in many ways. The aim of this study was to present the implementation process and results of the first two years of consecutive robot-assisted laparoscopic (RAL) colorectal procedures.......Implementation of robotic technology in surgery is challenging in many ways. The aim of this study was to present the implementation process and results of the first two years of consecutive robot-assisted laparoscopic (RAL) colorectal procedures....

  18. Robotic-assisted laparoscopic radical nephrectomy using the Da Vinci Si system: how to improve surgeon autonomy. Our step-by-step technique.

    Science.gov (United States)

    Davila, Hugo H; Storey, Raul E; Rose, Marc C

    2016-09-01

    Herein, we describe several steps to improve surgeon autonomy during a Left Robotic-Assisted Laparoscopic Radical Nephrectomy (RALRN), using the Da Vinci Si system. Our kidney cancer program is based on 2 community hospitals. We use the Da Vinci Si system. Access is obtained with the following trocars: Two 8 mm robotic, one 8 mm robotic, bariatric length (arm 3), 15 mm for the assistant and 12 mm for the camera. We use curved monopolar scissors in robotic arm 1, Bipolar Maryland in arm 2, Prograsp Forceps in arm 3, and we alternate throughout the surgery with EndoWrist clip appliers and the vessel sealer. Here, we described three steps and the use of 3 robotic instruments to improve surgeon autonomy. Step 1: the lower pole of the kidney was dissected and this was retracted upwards and laterally. This maneuver was performed using the 3rd robotic arm with the Prograsp Forceps. Step 2: the monopolar scissors was replaced (robotic arm 1) with the robotic EndoWrist clip applier, 10 mm Hem-o-Lok. The renal artery and vein were controlled and transected by the main surgeon. Step 3: the superior, posterolateral dissection and all bleeders were carefully coagulated by the surgeon with the EndoWrist one vessel sealer. We have now performed 15 RALRN following these steps. Our results were: blood loss 300 cc, console time 140 min, operating room time 200 min, anesthesia time 180 min, hospital stay 2.5 days, 1 incisional hernia, pathology: (13) RCC clear cell, (1) chromophobe and (1) papillary type 1. Tumor Stage: (5) T1b, (8) T2a, (2) T2b. We provide a concise, step-by-step technique for radical nephrectomy (RN) using the Da Vinci Si robotic system that may provide more autonomy to the surgeon, while maintaining surgical outcome equivalent to standard laparoscopic RN.

  19. Robot-assisted partial nephrectomy in contemporary practice

    Directory of Open Access Journals (Sweden)

    Youssef S. Tanagho

    2013-01-01

    Full Text Available Laparoscopic renal surgery is associated with reduced blood loss, shorter hospital stay, enhanced cosmesis, and more rapid convalescence relative to open renal surgery. Laparoscopic partial nephrectomy is a minimally invasive, nephron-sparing alternative to laparoscopic radical nephrectomy for the management of small renal masses. While offering similar oncological outcomes to laparoscopic radical nephrectomy, the technical challenges and prolonged learning curve associated with laparoscopic partial nephrectomy limit its wider dissemination. Robot-assisted partial nephrectomy, although still an evolving procedure with no long-term data, has emerged as a viable alternative to laparoscopic partial nephrectomy, with favorable preliminary outcomes. This article provides an overview of the role of robot-assisted partial nephrectomy in the management of renal cell carcinoma. The clinical indications and principles of surgical technique for this procedure are discussed. The oncological, renal functional, and perioperative outcomes of robot-assisted partial nephrectomy are also evaluated, as are complication rates.

  20. Robot-Assisted Laparoscopic Radical Prostatectomy for Patients with Prostatic Cancer and Factors Promoting Installation of the Robotic Surgical Equipment-Questionnaire Survey

    OpenAIRE

    塚本, 泰司; 田中, 滋

    2015-01-01

    We conducted a questionnaire survey of hospitals with robot-assisted surgical equipment to study changes of the surgical case loads after its installation and the managerial strategies for its purchase. The study included 154 hospitals (as of April 2014) that were queried about their radical prostatectomy case loads from January 2009 to December 2013, strategies for installation of the equipment in their hospitals, and other topics related to the study purpose. The overall response rate of ho...

  1. Robotic versus laparoscopic resection of liver tumours

    Science.gov (United States)

    Berber, Eren; Akyildiz, Hizir Yakup; Aucejo, Federico; Gunasekaran, Ganesh; Chalikonda, Sricharan; Fung, John

    2010-01-01

    Background There are scant data in the literature regarding the role of robotic liver surgery. The aim of the present study was to develop techniques for robotic liver tumour resection and to draw a comparison with laparoscopic resection. Methods Over a 1-year period, nine patients underwent robotic resection of peripherally located malignant lesions measuring <5 cm. These patients were compared prospectively with 23 patients who underwent laparoscopic resection of similar tumours at the same institution. Statistical analyses were performed using Student's t-test, χ2-test and Kaplan–Meier survival. All data are expressed as mean ± SEM. Results The groups were similar with regards to age, gender and tumour type (P = NS). Tumour size was similar in both groups (robotic −3.2 ± 1.3 cm vs. laparoscopic −2.9 ± 1.3 cm, P = 0.6). Skin-to-skin operative time was 259 ± 28 min in the robotic vs. 234 ± 17 min in the laparoscopic group (P = 0.4). There was no difference between the two groups regarding estimated blood loss (EBL) and resection margin status. Conversion to an open operation was only necessary in one patient in the robotic group. Complications were observed in one patient in the robotic and four patients in the laparoscopic groups. The patients were followed up for a mean of 14 months and disease-free survival (DFS) was equivalent in both groups (P = 0.6). Conclusion The results of this initial study suggest that, for selected liver lesions, a robotic approach provides similar peri-operative outcomes compared with laparoscopic liver resection (LLR). PMID:20887327

  2. Robotic assisted andrological surgery

    Science.gov (United States)

    Parekattil, Sijo J; Gudeloglu, Ahmet

    2013-01-01

    The introduction of the operative microscope for andrological surgery in the 1970s provided enhanced magnification and accuracy, unparalleled to any previous visual loop or magnification techniques. This technology revolutionized techniques for microsurgery in andrology. Today, we may be on the verge of a second such revolution by the incorporation of robotic assisted platforms for microsurgery in andrology. Robotic assisted microsurgery is being utilized to a greater degree in andrology and a number of other microsurgical fields, such as ophthalmology, hand surgery, plastics and reconstructive surgery. The potential advantages of robotic assisted platforms include elimination of tremor, improved stability, surgeon ergonomics, scalability of motion, multi-input visual interphases with up to three simultaneous visual views, enhanced magnification, and the ability to manipulate three surgical instruments and cameras simultaneously. This review paper begins with the historical development of robotic microsurgery. It then provides an in-depth presentation of the technique and outcomes of common robotic microsurgical andrological procedures, such as vasectomy reversal, subinguinal varicocelectomy, targeted spermatic cord denervation (for chronic orchialgia) and robotic assisted microsurgical testicular sperm extraction (microTESE). PMID:23241637

  3. The Incidence and Anatomy of Accessory Pudendal Arteries as Depicted on Multidetector-Row CT Angiography: Clinical Implications of Preoperative Evaluation for Laparoscopic and Robot-Assisted Radical Prostatectomy

    International Nuclear Information System (INIS)

    Park, Beom Jin; Sung, Deuk Jae; Kim, Min Ju; Cho, Sung Bum; Kim, Yun Hwan; Chung, Kyoo Byung; Kang, Seok Ho; Cheon, Jun

    2009-01-01

    To help preserve accessory pudendal arteries (APAs) and to ensure optimal postoperative sexual function after a laparoscopic or robot-assisted radical prostatectomy, we have evaluated the incidence of APAs as detected on multidetector-row CT (MDCT) angiography and have provided a detailed anatomical description. The distribution of APAs was evaluated in 121 consecutive male patients between February 2006 and July 2007 who underwent 64- channel MDCT angiography of the lower extremities. We defined an APA as any artery located within the periprostatic region running parallel to the dorsal vascular complex. We also subclassified APAs into lateral and apical APAs. Two radiologists retrospectively evaluated the origin, course and number of APAs; the final APA subclassification based on MDCT angiography source data was determined by consensus. We identified 44 APAs in 36 of 121 patients (30%). Two distinct varieties of APAs were identified. Thirty-three APAs (75%) coursed near the anterolateral region of the prostatic apex, termed apical APAs. The remaining 11 APAs (25%) coursed along the lateral aspect of the prostate, termed lateral APAs. All APAs originated from the internal obturator artery and iliac artery or a branch of the iliac artery such as the inferior vesical artery. The majority of apical APAs arose from the internal obturator artery (84%). Seven patients (19%) had multiple APAs. APAs are more frequently detected by the use of MDCT angiography than as suggested by previous surgical studies. The identification of APAs on MDCT angiography may provide useful information for the surgical preservation of APAs during a laparoscopic or robot-assisted radical prostatectomy

  4. Current perspectives in robotic assisted surgery.

    Science.gov (United States)

    Binet, Aurélien; Ballouhey, Quentin; Chaussy, Yann; de Lambert, Guénolée; Braïk, Karim; Villemagne, Thierry; Becmeur, François; Fourcade, Laurent; Lardy, Hubert

    2018-02-23

    From classical surgery to Robotic Assisted Surgery, there is a long way allowed by Minimal Invasive Surgery' improvements. The last three decades have witnessed a prodigious development of minimally invasive surgery (MIS) and especially in the field of laparoscopic pediatric surgery but there are several limitations in the use of conventional laparoscopic surgery and Robotic Assisted Surgery was developed to relieve these drawbacks. This new technology enables today the performance of a wide variety of procedures in children with a minimally invasive approach. As for all new technologies, an objective evaluation is essential with the need to respond to several questions: Is the technology feasible? Is the technology safe? Is the technology efficient? Does it bring about benefits compared with current technology? What are the procedures derived from most benefits of robotic assistance? How to assume the transition from open surgery to Minimal Invasive access for RAS? In the first part of this article, the authors give details about technical concerns and then describe the implementation process with its organization, pitfalls, successes, and issues from human resources and financial standpoints. The learning curve is then described and a special focus on small children weighing less than 15 Kg is developed. Finally, the concept of evaluation of this emerging technology is evocated and financial concerns are developed.

  5. Possible benefits of robot-assisted rectal cancer surgery regarding urological and sexual dysfunction

    DEFF Research Database (Denmark)

    Broholm Andersen, Malene; Pommergaard, H-C; Gögenür, I

    2015-01-01

    AIM: Robot-assisted surgery for rectal cancer may result in lower rates of urogenital dysfunction compared with laparoscopic surgery. A systematic review was conducted of studies reporting urogenital dysfunction after robot-assisted rectal cancer surgery. METHOD: PubMed, Embase and the Cochrane...... Library were systematically searched in February 2014. All studies investigating urogenital function after robot-assisted rectal cancer surgery were identified. The inclusion criteria for meta-analysis studies required comparison of robot-assisted with laparoscopic surgery and the evaluation of urological...... to four including 152 patients in the robotic group and 161 in the laparoscopic group, without heterogeneity. The IPSS score at 3 and 12 months favoured robot-assisted surgery [mean difference (MD) -1.58; 95% CI (-3.1, -0.0), [P = 0.04; and MD -0.90 (-1.81, -0.02), P = 0.05]. IIEF scores at 3 months...

  6. Laparoscopic Habib 4X: a bipolar radiofrequency device for bloodless laparoscopic liver resection.

    Science.gov (United States)

    Pai, M; Navarra, G; Ayav, A; Sommerville, C; Khorsandi, S K; Damrah, O; Jiao, L R; Habib, N A

    2008-01-01

    In recent years the progress of laparoscopic procedures and the development of new and dedicated technologies have made laparoscopic hepatic surgery feasible and safe. In spite of this laparoscopic liver resection remains a surgical procedure of great challenge because of the risk of massive bleeding during liver transection and the complicated biliary and vascular anatomy in the liver. A new laparoscopic device is reported here to assist liver resection laparoscopically. The laparoscopic Habib 4X is a bipolar radiofrequency device consisting of a 2 x 2 array of needles arranged in a rectangle. It is introduced perpendicularly into the liver, along the intended transection line. It produces coagulative necrosis of the liver parenchyma sealing biliary radicals and blood vessels and enables bloodless transection of the liver parenchyma. Twenty-four Laparoscopic liver resections were performed with LH4X out of a total of 28 attempted resections over 12 months. Pringle manoeuvre was not used in any of the patients. None of the patients required intraoperative transfusion of red cells or blood products. Laparoscopic liver resection can be safely performed with laparoscopic Habib 4X with a significantly low risk of intraoperative bleeding or postoperative complications.

  7. Robot-assisted laparoscopic adenomyomectomy of adenomyotic nodule implanted in the uterine endometrium manifesting as endometrial cancer: a case report and literature review.

    Science.gov (United States)

    Jeon, J H; Jeong, K; Moon, H S

    2017-01-01

    Thickened uterine endometrium with abnormal uterine bleeding highly suggests endometrial hyperplasia or endometrial carcinoma. A case of 35-year-old nulliparous woman came to our department with endometrial mass manifesting as endometrial cancer. Transrectal ultrasonography and magnetic resonance imaging (MRI) showed an 8x6 cm multicystic, ill-defined mass compacted at the uterine endometrium, the anterior wall of the uterus, and 3x3 cm heterogenous mass at the left adnexa. The edometrial mass showed multiple septations with enhancement and low-signal intensity on T2-weighted images. After endometrial biopsy was done and simple hyperplasia without atypia was observed at the histopathologic finding, the patient underwent robot-assisted laparoscopy and diagnosed as adenomyoma at the frozen pathology. After adenomyomectomy, permanent pathologic analysis revealed the same result and she recovered without any complications and responded well to gonadotropin-releasing hormone (GnRH) agonist therapy.

  8. Retzus-sparing robotic-assisted laparoscopic radical prostatectomy: a step–by-step technique description of this first brazilian experience

    Directory of Open Access Journals (Sweden)

    Marcos Tobias-Machado

    Full Text Available Abstract Introduction: Retzus-sparing robotic-assisted radical prostatectomy(RARP is a newly approach that preserve the Retzus structures and provide better recovery of continence and erectile function. In Brazil, this approach has not yet been previously reported. Objective: Our goal is to describe Step-by-Step the Retzus-sparing RARP surgical technique and report our first Brazilian experience. Methods: We present a case of a 60-year-old white man with low risk prostate cancer. Surgical materials were four arms Da Vinci robotic platform system, six transperitoneal portals, two prolene wires and Polymer Clips. This surgical technique was step-by-step described according to Galfano et al. One additional step was added as a modification of Galfano et al. Primary technique description: The closure of the Denovellier fascia. Results: We have operated one patient with this technique. The operative time was 180minutes, console time was135 min, the blood loss was 150ml, none perioperative or postoperative complications was found, hospital stay of 01 day. The anatomopathological classification revealed a pT2aN0M0 specimen with free surgical margins. The patient achieved continence immediately after bladder stent retrieval. Full erection reported after 30 days of surgery. Conclusion: Retzus-sparing RARP approach is feasible and reproducible. However, further comparative studies are necessary to demonstrate potential benefits in continence and sexual outcomes over the standard approaches.

  9. The Curie–Da Vinci Connection: 5-Years' Experience With Laparoscopic (Robot-Assisted) Implantation for High-Dose-Rate Brachytherapy of Solitary T2 Bladder Tumors

    Energy Technology Data Exchange (ETDEWEB)

    Steen-Banasik, Elzbieta M. van der, E-mail: E.vanderSteen-Banasik@radiotherapiegroep.nl [Radiotherapiegroep, Arnhem (Netherlands); Smits, Geert A.H.J. [Department of Urology, Rijnstate Hospital, Arnhem (Netherlands); Oosterveld, Bernard J.; Janssen, Theo; Visser, Andries G. [Radiotherapiegroep, Arnhem (Netherlands)

    2016-08-01

    Purpose: To report experience and early results of laparoscopic implantation for interstitial brachytherapy (BT) of solitary bladder tumors and the feasibility of a high-dose-rate (HDR) schedule. Methods and Materials: From December 2009 to April 2015, 57 patients with a T2 solitary bladder tumor were treated in Arnhem with transurethral bladder resection followed by external beam irradiation, applied to the bladder and regional iliac lymph nodes, 40 Gy in 20 fractions, 5 fractions per week, and within 1 week interstitial HDR BT, in selected cases combined with partial cystectomy and lymph node dissection. The BT catheters were placed via a transabdominal approach with robotic assistance from a Da Vinci robot after a successful initial experience with a nonrobotic laparoscopic approach. The fraction schedule for HDR was 10 fractions of 2.5 Gy, 3 fractions per day. This was calculated to be equivalent to a reference low-dose-rate schedule of 30 Gy in 60 hours. Data for oncologic outcomes and toxicity (Common Toxicity Criteria version 4) were prospectively collected. Results: These modifications resulted in an average postoperative hospitalization of 6 days, minimal blood loss, and no wound healing problems. Two patients had severe acute toxicity: 1 pulmonary embolism grade 4 and 1 cardiac death. Late toxicity was mild (n=2 urogenital grade 3 toxicity). The median follow-up was 2 years. Using cumulative incidence competing risk analysis, the 2-year overall, disease-free, and disease-specific survival and local control rates were 59%, 71%, 87%, and 82%, respectively. Conclusions: The benefits of minimally invasive surgery for implantation of BT catheters and the feasibility of HDR BT in bladder cancer are documented. The patient outcome and adverse events are comparable to the best results published for a bladder-sparing approach.

  10. Return to work following robot-assisted laparoscopic and open retropubic radical prostatectomy: A single-center cohort study to compare duration of sick leave.

    Science.gov (United States)

    von Mechow, Stefanie; Graefen, Markus; Haese, Alexander; Tennstedt, Pierre; Pehrke, Dirk; Friedersdorff, Frank; Beyer, Burkhard

    2018-06-01

    To compare the duration of sick leave in patients with localized prostate cancer after robot-assisted radical prostatectomy (RARP) and open retropubic RP (ORP) at a German high-volume prostate cancer center. The data of 1,415 patients treated with RP at Martini Klinik, Prostate Cancer Center between 2012 and 2016 were, retrospectively, analyzed. Information on employment status, monthly revenues and days of work missed due to sickness were assessed via online questionnaire. Additional data were retrieved from our institutional database. Medians and interquartile ranges (IQR) were reported for continuous data. Cox proportional hazard analysis was performed to compare both surgical techniques for return to work time after RP. Median time elapsed between surgery and return to work comprised 42 days in patients undergoing RARP (IQR: 21-70) and ORP (IQR: 28-84, P = 0.05). In Cox regression analysis, surgical approach showed no impact on return to work time (RARP vs. ORP hazard ratio = 1, 95% CI: 0.91-1.16, P = 0.69). Return to work time was significantly associated with employment status, physical workload and monthly income (all PLimitation of this study is the nonrandomized design in a single-center. As the surgical approach did not show any influence on the number of days missed from work in patients undergoing RP, no superiority of either RARP or ORP could be identified for return to work time in a German cohort. Both surgical approaches are safe options usually allowing the patients to resume normal activities including work after an appropriate convalescence period. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Oncologic results of laparoscopic liver resection for malignant liver tumors.

    Science.gov (United States)

    Akyuz, Muhammet; Yazici, Pinar; Yigitbas, Hakan; Dural, Cem; Okoh, Alexis; Aliyev, Shamil; Aucejo, Federico; Quintini, Cristiano; Fung, John; Berber, Eren

    2016-02-01

    There are scant data regarding oncologic outcomes of laparoscopic liver resection (LLR). The aim of this study is to analyze the oncologic outcomes of LLR for malignant liver tumors (MLT). This was a prospective IRB-approved study of 123 patients with MLT undergoing LLR. Kaplan-Meier disease-free (DFS) and overall survival (OS) was calculated. Tumor type was colorectal in 61%, hepatocellular cancer in 21%, neuroendocrine in 5% and others in 13%. Mean tumor size was 3.2 ± 1.9 cm and number of tumors 1.6 ± 1.2. A wedge resection or segmentectomy was performed in 63.4%, bisegmentectomy in 24.4%, and hemihepatectomy in 12.2%. Procedures were totally laparoscopic in 67% and hand-assisted in 33%. Operative time was 235.2 ± 94.3 min, and conversion rate 7.3%. An R0 resection was achieved in 90% of patients and 94% of tumors. Median hospital stay was 3 days. Morbidity was 22% and mortality 0.8%. For patients with colorectal liver metastasis, DFS and OS at 2 years was 47% and 88%, respectively. This study shows that LLR is a safe and efficacious treatment for selected patients with MLT. Complete resection and margin recurrence rate are comparable to open series in the literature. © 2015 Wiley Periodicals, Inc.

  12. Does transition from the da Vinci Si to Xi robotic platform impact single-docking technique for robot-assisted laparoscopic nephroureterectomy?

    Science.gov (United States)

    Patel, Manish N; Aboumohamed, Ahmed; Hemal, Ashok

    2015-12-01

    To describe our robot-assisted nephroureterectomy (RNU) technique for benign indications and RNU with en bloc excision of bladder cuff (BCE) and lymphadenectomy (LND) for malignant indications using the da Vinci Si and da Vinci Xi robotic platform, with its pros and cons. The port placement described for Si can be used for standard and S robotic systems. This is the first report in the literature on the use of the da Vinci Xi robotic platform for RNU. After a substantial experience of RNU using different da Vinci robots from the standard to the Si platform in a single-docking fashion for benign and malignant conditions, we started using the newly released da Vinci Xi robot since 2014. The most important differences are in port placement and effective use of the features of da Vinci Xi robot while performing simultaneous upper and lower tract surgery. Patient positioning, port placement, step-by-step technique of single docking RNU-LND-BCE using the da Vinci Si and da Vinci Xi robot are shown in an accompanying video with the goal that centres using either robotic system benefit from the hints and tips. The first segment of video describes RNU-LND-BCE using the da Vinci Si followed by the da Vinci Xi to highlight differences. There was no need for patient repositioning or robot re-docking with the new da Vinci Xi robotic platform. We have experience of using different robotic systems for single docking RNU in 70 cases for benign (15) and malignant (55) conditions. The da Vinci Xi robotic platform helps operating room personnel in its easy movement, allows easier patient side-docking with the help of its boom feature, in addition to easy and swift movements of the robotic arms. The patient clearance feature can be used to avoid collision with the robotic arms or the patient's body. In patients with challenging body habitus and in situations where bladder cuff management is difficult, modifications can be made through reassigning the camera to a different port with

  13. Robot-assisted Heller's myotomy for achalasia in children.

    Science.gov (United States)

    Altokhais, Tariq; Mandora, Hala; Al-Qahtani, Ayed; Al-Bassam, Abdulrahman

    2016-12-01

    Achalasia is rare in children. Surgical options include open, laparoscopic and robotic approaches. However, Heller's myotomy remains the treatment of choice. This report describes our experience with robot-assisted Heller's myotomy in children and presents a review of the literature. Included in this study are children who underwent robot-assisted Heller's myotomy for esophageal achalasia via the Da Vinci surgical system between 2004 and 2015 at King Saud University Medical City, Riyadh, Saudi Arabia. The medical records of these patients were reviewed for demographic data, presenting symptoms, diagnostic modalities, operative procedures, complications, outcomes and follow-ups. Six patients were identified. The age of the patients at surgery ranged between 2 and 12 years (mean 7.1 years). The most common presenting symptoms were dysphagia, vomiting and nocturnal cough. Contrast swallow and upper gastrointestinal endoscopy established a diagnosis of esophageal achalasia in all of the patients. Four patients underwent esophageal dilatation 2-5 times before the definitive procedure. All patients underwent successful robot-assisted Heller's myotomy with concomitant partial posterior fundoplication. The postoperative course was uneventful. Five patients had a complete resolution of the symptoms and one patient improved. The follow-up assessments have been consistent and have ranged from 0.5 to 11 years (mean 4.4 years). Robotic-assisted Heller's myotomy for esophageal achalasia in children is safe and effective and is a suitable alternative to open and laparoscopic approaches.

  14. A Pilot Study of Laparoscopic Doppler Ultrasound Probe to Map Arterial Vascular Flow within the Neurovascular Bundle during Robot-Assisted Radical Prostatectomy

    Directory of Open Access Journals (Sweden)

    Ketan K. Badani

    2013-01-01

    Full Text Available Purpose. To report on the feasibility of a new Laparoscopic Doppler ultrasound (LDU technology to aid in identifying and preserving arterial blood flow within the neurovascular bundle (NVB during robotic prostatectomy (RARP. Materials and Methods. Nine patients with normal preoperative potency and scheduled for a bilateral nerve-sparing procedure were prospectively enrolled. LDU was used to measure arterial flow at 6 anatomic locations alongside the prostate, and signal intensity was evaluated by 4 independent reviewers. Measurements were made before and after NVB dissection. Modifications in nerve-sparing procedure due to LDU use were recorded. Postoperative erectile function was assessed. Fleiss Kappa statistic was used to evaluate inter-rater agreement for each of the 12 measurements. Results. Analysis of Doppler signal intensity showed maintenance of flow in 80% of points assessed, a decrease in 16%, and an increase in 4%. Plane of NVB dissection was altered in 5 patients (56% on the left and in 4 patients (44% on the right. There was good inter-rater reliability for the 4 reviewers. Use of the probe did not significantly increase operative time or result in any complications. Seven (78% patients had recovery of erections at time of the 8-month follow-up visit. Conclusions. LDU is a safe, easy to use, and effective method to identify local vasculature and anatomic landmarks during RARP, and can potentially be used to achieve greater nerve preservation.

  15. Good results after laparoscopic marsupialisation of simple liver cysts

    DEFF Research Database (Denmark)

    Nørregaard, Christian Lolle; Ainsworth, Alan Patrick

    2014-01-01

    INTRODUCTION: Large simple liver cysts often tend to be symptomatic with pain being the most common symptom. MATERIAL AND METHODS: This was a retrospective study of patients who had intended laparoscopic surgery for liver cysts between December 2007 and December 2012 at a single institution...

  16. Laparoscopic management of cystic disease of the liver.

    Science.gov (United States)

    Albrink, M H; McAllister, E W; Rosemurgy, A S; Karl, R C; Carey, L C

    1994-04-01

    Laparoscopic surgical procedures are increasing in scope and in variety. The benefits of decreased wound morbidity and pain have been well documented for multiple procedures that have traditionally required laparotomy. Although there are few controlled studies to document them, these benefits may be evident from simple clinical observation. Cystic disease of the liver is a condition that is treated largely for symptomatic reasons. The so-called noninvasive or radiographic guided methods of treatment for cystic disease of the liver are fraught with high recurrence rates. We present four cases of cystic disease of the liver treated laparoscopically, followed with pertinent discussion.

  17. [Simulation-based robot-assisted surgical training].

    Science.gov (United States)

    Kolontarev, K B; Govorov, A V; Rasner, P I; Sheptunov, S A; Prilepskaya, E A; Maltsev, E G; Pushkar, D Yu

    2015-12-01

    Since the first use of robotic surgical system in 2000, the robot-assisted technology has gained wide popularity throughout the world. Robot-assisted surgical training is a complex issue that requires significant efforts from students and teacher. During the last two decades, simulation-based training had received active development due to wide-spread occurrence and popularization of laparoscopic and robot-assisted surgical techniques. We performed a systematic review to identify the currently available simulators for robot-assisted surgery. We searched the Medline and Pubmed, English sources of literature data, using the following key words and phrases: "robotics", "robotic surgery", "computer assisted surgery", "simulation", "computer simulation", "virtual reality", "surgical training", and "surgical education". There were identified 565 publications, which meet the key words and phrases; 19 publications were selected for the final analysis. It was established that simulation-based training is the most promising teaching tool that can be used in the training of the next generation robotic surgeons. Today the use of simulators to train surgeons is validated. Price of devices is an obvious barrier for inclusion in the program for training of robotic surgeons, but the lack of this tool will result in a sharp increase in the duration of specialists training.

  18. Real-time image guidance in laparoscopic liver surgery

    DEFF Research Database (Denmark)

    Kenngott, Hannes G.; Wagner, Martin; Gondan, Matthias

    2014-01-01

    Background: Laparoscopic liver surgery is particularly challenging owing to restricted access, risk of bleeding and lack of haptic feedback. Navigation systems have the potential to improve information on the exact position of intrahepatic tumors, and thus facilitate oncological resection....... This study aims to evaluate the feasibility of a commercially available augmented reality (AR) guidance system employing intraoperative robotic C-arm cone-beam computed tomography (CBCT) for laparoscopic liver surgery. Methods: A human liver-like phantom with sixteen target fiducials was used to evaluate...... the Syngo iPilot® AR system. Subsequently, the system was used for the laparoscopic resection of a hepatocellular carcinoma in segment 7 of a 50-year-old male patient. Results: In the phantom experiment the AR system showed a mean target registration error of 0.96 mm ± 0.52 mm with a maximum error of 2...

  19. Robot-assisted partial nephrectomy in contemporary practice

    Energy Technology Data Exchange (ETDEWEB)

    Tanagho, Youssef S.; Bhayani, Sam B.; Figenshau, Robert S., E-mail: tanaghoy@wudosis.wustl.edu [Division of Urologic Surgery, Washington University School of Medicine, St. Louis, MO (United States)

    2013-01-11

    Laparoscopic renal surgery is associated with reduced blood loss, shorter hospital stay, enhanced cosmesis, and more rapid convalescence relative to open renal surgery. Laparoscopic partial nephrectomy (LPN) is a minimally invasive, nephron-sparing alternative to laparoscopic radical nephrectomy (RN) for the management of small renal masses. While offering similar oncological outcomes to laparoscopic RN, the technical challenges and prolonged learning curve associated with LPN limit its wider dissemination. Robot-assisted partial nephrectomy (RAPN), although still an evolving procedure with no long-term data, has emerged as a viable alternative to LPN, with favorable preliminary outcomes. This article provides an overview of the role of RAPN in the management of renal cell carcinoma. The clinical indications and principles of surgical technique for this procedure are discussed. The oncological, renal functional, and perioperative outcomes of RAPN are also evaluated, as are complication rates.

  20. Robot-assisted partial nephrectomy in contemporary practice

    International Nuclear Information System (INIS)

    Tanagho, Youssef S.; Bhayani, Sam B.; Figenshau, Robert S.

    2013-01-01

    Laparoscopic renal surgery is associated with reduced blood loss, shorter hospital stay, enhanced cosmesis, and more rapid convalescence relative to open renal surgery. Laparoscopic partial nephrectomy (LPN) is a minimally invasive, nephron-sparing alternative to laparoscopic radical nephrectomy (RN) for the management of small renal masses. While offering similar oncological outcomes to laparoscopic RN, the technical challenges and prolonged learning curve associated with LPN limit its wider dissemination. Robot-assisted partial nephrectomy (RAPN), although still an evolving procedure with no long-term data, has emerged as a viable alternative to LPN, with favorable preliminary outcomes. This article provides an overview of the role of RAPN in the management of renal cell carcinoma. The clinical indications and principles of surgical technique for this procedure are discussed. The oncological, renal functional, and perioperative outcomes of RAPN are also evaluated, as are complication rates.

  1. The impact of marketing language on patient preference for robot-assisted surgery.

    Science.gov (United States)

    Dixon, Peter R; Grant, Robert C; Urbach, David R

    2015-02-01

    Robot-assisted surgery is gaining momentum as a new trend in minimally invasive surgery. With limited evidence supporting its use in place of the far less expensive conventional laparoscopic surgery, it has been suggested that marketing pressure is partly responsible for its widespread adoption. The impact of phrases that promote the novelty of robot-assisted surgery on patient decision making has not been investigated. We conducted a discrete choice experiment to elicit preference of partial colectomy technique for a hypothetical diagnosis of colon cancer. A convenience sample of 38 participants in an ambulatory general surgery clinic consented to participate. Each participant made 2 treatment decisions between robot-assisted surgery and conventional laparoscopic surgery, with robot-assisted surgery described as "innovative" and "state-of-the-art" in one of the decisions (marketing frame), and by a disclosure of the uncertainty of available evidence in the other (evidence-based frame). The magnitude of the framing effect was large with 12 of 38 subjects (31.6%, P = .005) selecting robot-assisted surgery in the marketing frame and not the evidence-based frame. This is the first study to our knowledge to demonstrate that words that highlight novelty have an important influence on patient preference for robot-assisted surgery and that use of more neutral language can mitigate this effect. © The Author(s) 2014.

  2. Two years of experience with robot-assisted anti-reflux surgery

    DEFF Research Database (Denmark)

    Sanberg Jensen, Jonas; Kold Antonsen, Henning; Durup, Jesper

    2017-01-01

    Background and aims Robot-assisted anti-reflux surgery (RAAS) is an alternative to conventional laparoscopic anti-reflux surgery (CLAS). The purpose of this study was to evaluate initial Danish experiences with robot-assisted anti-reflux surgery compared to conventional laparoscopic anti-reflux...... significantly dependent on type of fundic wrap with reoperation of Nissen fundoplication being dysphagia and reoperation of Toupet being recurrent reflux (p = 0.008). There was no clearly determined learning curve. Conclusions RAAS was safe, feasible and with equal efficacy to CLAS. There were however...

  3. Robotic-assisted vesicovaginal fistula repair using an extravesical approach without interposition grafting.

    Science.gov (United States)

    Kelly, Erin; Wu, Maria Y; MacMillan, J Barry

    2018-03-01

    Post-hysterectomy vesicovaginal fistula (VVF) is rare. In addition to conventional abdominal and vaginal approaches, robotic-assisted VVF repairs have recently been described. We present a case of an extravesical, robotic-assisted VVF repair, without placement of an interposition graft performed in a Canadian teaching center. A 51-year-old woman presented with urinary incontinence 5 days after laparoscopic hysterectomy. Computed tomography cystogram, cystoscopy, and methylene blue dye test, confirmed a VVF above the bladder trigone. The patient underwent a robotic-assisted VVF repair 3 months after presentation, without complication. An abdominal, extravesical approach was used. Operative time was 116 min and repeat CT cystogram showed no evidence of persistent. We have demonstrated that a VVF repair, using a robotic-assisted, extravesical approach without interposition graft placement, can be safe, less invasive and have a successful outcome at 1 year of follow-up.

  4. [Robot assisted Frykman-Goldberg procedure. Case report].

    Science.gov (United States)

    Zubieta-O'Farrill, Gregorio; Ramírez-Ramírez, Moisés; Villanueva-Sáenz, Eduardo

    2017-12-01

    Rectal prolapse is defined as the protrusion of the rectal wall through the anal canal; with a prevalence of less than 0.5%. The most frequent symptoms include pain, incomplete defecation sensation with blood and mucus, fecal incontinence and/or constipation. The surgical approach can be perineal or abdominal with the tendency for minimal invasion. Robot-assisted procedures are a novel option that offer technique advantages over open or laparoscopic approaches. 67 year-old female, who presented with rectal prolapse, posterior to an episode of constipation, that required manual reduction, associated with transanal hemorrhage during defecation and occasional fecal incontinence. A RMI defecography was performed that reported complete rectal and uterine prolapse, and cystocele. A robotic assisted Frykman-Goldberg procedure wass performed. There are more than 100 surgical procedures for rectal prolapse treatment. We report the first robot assisted procedure in Mexico. Robotic assisted surgery has the same safety rate as laparoscopic surgery, with the advantages of better instrument mobility, no human hand tremor, better vision, and access to complicated and narrow areas. Robotic surgery as the surgical treatment is a feasible, safe and effective option, there is no difference in recurrence and function compared with laparoscopy. It facilitates the technique, improves nerve preservation and bleeding. Further clinical, prospective and randomized studies to compare the different minimal invasive approaches, their functional and long term results for this pathology are needed. Copyright © 2016 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  5. Laparoscopic resection of a giant exophytic liver haemangioma with the laparoscopic Habib 4× radiofrequency device.

    Science.gov (United States)

    Acharya, Metesh; Panagiotopoulos, Nikolaos; Bhaskaran, Premjithlal; Kyriakides, Charis; Pai, Madhava; Habib, Nagy

    2012-08-27

    Haemangiomas are the most common solitary benign neoplasm of the liver with an incidence ranging from 5% to 20%. Although usually small and asymptomatic, they may reach considerable proportions and rarely give rise to life-threatening complications. Surgical intervention is required for incapacitating symptoms, established complications, and diagnostic uncertainty. The resection of haemangiomas demands meticulous surgical technique, owing to their high vascularity and the concomitant risk of intra-operative haemorrhage. Laparoscopic resection of giant haemangiomas is even more challenging, and has only been reported twice. We here report the case of a giant 10 cm liver haemangioma which was successfully resected laparoscopically using the laparoscopic HabibTM 4×, a bipolar radiofrequency device, without clamping major vessels and with minimal blood loss. Transfusion of blood or blood products was not required. The patient had an uneventful recovery and was asymptomatic at 7-mo follow-up.

  6. Laparoscopic management of diaphragmatic endometriosis by three different approaches.

    Science.gov (United States)

    Roman, Horace; Darwish, Basma; Provost, Delphine; Baste, Jean-Marc

    2016-08-01

    To report our three surgical approaches in the management of diaphragmatic endometriosis. Video article presenting laparoscopic surgical techniques, with and without robotic assistance. University hospital. Nulliparas with deep endometriosis associated with multiple endometriosis lesions of the diaphragm. Laparoscopic approach in women who present with small black-pigmented diaphragmatic lesions, with or without infiltration of the diaphragm, which are ablated using plasma energy. Robotic-assisted laparoscopic route in larger deep infiltrating implants, which are resected. To avoid phrenic nerve injury, robotic-assisted thoracoscopy is preferred in large lesions involving the central tendon of the diaphragm. The steps of each technique are emphasized. Surgical technique reports in anonymous patients are exempted from ethical approval by the Institutional Review Board. Seven patients have been managed by these procedures from July 2015 to March 2016. Patients' functional outcomes were uneventful, with no phrenic nerve palsy or residual chest and right shoulder pain. By combining resection and ablation techniques, the laparoscopy and thoracoscopy route, conventional and robotic-assisted minimally invasive approach, we offer a surgical strategy that is as conservative as possible, with an aim to limit postoperative adhesions between the liver and the diaphragm, and avoid diaphragmatic paralysis. Copyright © 2016 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  7. Robotic assistants for universal access

    OpenAIRE

    Keates, Simeon; Kyberd, Peter J.

    2017-01-01

    Much research is now focusing on how technology is moving away from the traditional computer to a range of smart devices in smart environments, the so-called Internet of Things. With this increase in computing power and decrease in form factor, we are approaching the possibility of a new generation of robotic assistants able to perform a range of tasks and activities to support all kinds of users. However, history shows that unless care is taken early in the design process, the users who may ...

  8. Laparoscopic Navigated Liver Resection: Technical Aspects and Clinical Practice in Benign Liver Tumors

    Directory of Open Access Journals (Sweden)

    Markus Kleemann

    2012-01-01

    Full Text Available Laparoscopic liver resection has been performed mostly in centers with an extended expertise in both hepatobiliary and laparoscopic surgery and only in highly selected patients. In order to overcome the obstacles of this technique through improved intraoperative visualization we developed a laparoscopic navigation system (LapAssistent to register pre-operatively reconstructed three-dimensional CT or MRI scans within the intra-operative field. After experimental development of the navigation system, we commenced with the clinical use of navigation-assisted laparoscopic liver surgery in January 2010. In this paper we report the technical aspects of the navigation system and the clinical use in one patient with a large benign adenoma. Preoperative planning data were calculated by Fraunhofer MeVis Bremen, Germany. After calibration of the system including camera, laparoscopic instruments, and the intraoperative ultrasound scanner we registered the surface of the liver. Applying the navigated ultrasound the preoperatively planned resection plane was then overlain with the patient's liver. The laparoscopic navigation system could be used under sterile conditions and it was possible to register and visualize the preoperatively planned resection plane. These first results now have to be validated and certified in a larger patient collective. A nationwide prospective multicenter study (ProNavic I has been conducted and launched.

  9. Robot-assisted pancreatic surgery: a systematic review of the literature

    Science.gov (United States)

    Strijker, Marin; van Santvoort, Hjalmar C; Besselink, Marc G; van Hillegersberg, Richard; Borel Rinkes, Inne HM; Vriens, Menno R; Molenaar, I Quintus

    2013-01-01

    Background To potentially improve outcomes in pancreatic resection, robot-assisted pancreatic surgery has been introduced. This technique has possible advantages over laparoscopic surgery, such as its affordance of three-dimensional vision and increased freedom of movement of instruments. A systematic review was performed to assess the safety and feasibility of robot-assisted pancreatic surgery. Methods The literature published up to 30 September 2011 was systematically reviewed, with no restrictions on publication date. Studies reporting on over five patients were included. Animal studies, studies not reporting morbidity and mortality, review articles and conference abstracts were excluded. Data were extracted and weighted means were calculated. Results A total of 499 studies were screened, after which eight cohort studies reporting on a total of 251 patients undergoing robot-assisted pancreatic surgery were retained for analysis. Weighted mean operation time was 404 ± 102 min (510 ± 107 min for pancreatoduodenectomy only). The rate of conversion was 11.0% (16.4% for pancreatoduodenectomy only). Overall morbidity was 30.7% (n = 77), most frequently involving pancreatic fistulae (n = 46). Mortality was 1.6%. Negative surgical margins were obtained in 92.9% of patients. The rate of spleen preservation in distal pancreatectomy was 87.1%. Conclusions Robot-assisted pancreatic surgery seems to be safe and feasible in selected patients and, in left-sided resections, may increase the rate of spleen preservation. Randomized studies should compare the respective outcomes of robot-assisted, laparoscopic and open pancreatic surgery. PMID:23216773

  10. Laparoscopic liver resection for malignancy: a review of the literature.

    Science.gov (United States)

    Alkhalili, Eyas; Berber, Eren

    2014-10-07

    To review the published literature about laparoscopic liver resection for malignancy. A PubMed search was performed for original published studies until June 2013 and original series containing at least 30 patients were reviewed. All forms of hepatic resections have been described ranging from simple wedge resections to extended right or left hepatectomies. The usual approach is pure laparoscopic, but hand-assisted, as well as robotic approaches have been described. Most studies showed comparable results to open resection in terms of operative blood loss, postoperative morbidity and mortality. Many of them showed decreased postoperative pain, shorter hospital stays, and even lower costs. Oncological results including resection margin status and long-term survival were not inferior to open resection. In the hands of experienced surgeons, laparoscopic liver resection for malignant lesions is safe and offers some short-term advantages over open resection. Oncologically, similar survival rates have been observed in patients treated with the laparoscopic approach when compared to their open resection counterparts.

  11. Advancements in robotic-assisted thoracic surgery.

    Science.gov (United States)

    Steenwyk, Brad; Lyerly, Ralph

    2012-12-01

    Advancements in robotic-assisted thoracic surgery present potential advantages for patients as well as new challenges for the anesthesia and surgery teams. This article describes the major aspects of the surgical approach for the most commonly performed robotic-assisted thoracic surgical procedures as well as the pertinent preoperative, intraoperative, and postoperative anesthetic concerns. Copyright © 2012. Published by Elsevier Inc.

  12. [Laparoscopic liver resection: lessons learned after 132 resections].

    Science.gov (United States)

    Robles Campos, Ricardo; Marín Hernández, Caridad; Lopez-Conesa, Asunción; Olivares Ripoll, Vicente; Paredes Quiles, Miriam; Parrilla Paricio, Pascual

    2013-10-01

    After 20 years of experience in laparoscopic liver surgery there is still no clear definition of the best approach (totally laparoscopic [TLS] or hand-assisted [HAS]), the indications for surgery, position, instrumentation, immediate and long-term postoperative results, etc. To report our experience in laparoscopic liver resections (LLRs). Over a period of 10 years we performed 132 LLRs in 129 patients: 112 malignant tumours (90 hepatic metastases; 22 primary malignant tumours) and 20 benign lesions (18 benign tumours; 2 hydatid cysts). Twenty-eight cases received TLS and 104 had HAS. 6 right hepatectomies (2 as the second stage of a two-stage liver resection); 6 left hepatectomies; 9 resections of 3 segments; 42 resections of 2 segments; 64 resections of one segment; and 5 cases of local resections. There was no perioperative mortality, and morbidity was 3%. With TLS the resection was completed in 23/28 cases, whereas with HAS it was completed in all 104 cases. Transfusion: 4,5%; operating time: 150min; and mean length of stay: 3,5 days. The 1-, 3- and 5-year survival rates for the primary malignant tumours were 100, 86 and 62%, and for colorectal metastases 92, 82 and 52%, respectively. LLR via both TLS and HAS in selected cases are similar to the results of open surgery (similar 5-year morbidity, mortality and survival rates) but with the advantages of minimally invasive surgery. Copyright © 2012 AEC. Published by Elsevier Espana. All rights reserved.

  13. [Robotic assistance in gynaecological surgery: State-of-the-art].

    Science.gov (United States)

    Monsarrat, N; Collinet, P; Narducci, F; Leblanc, E; Vinatier, D

    2009-05-01

    From the Automated Endoscopic System for Optimal Positioning (AESOP), a robotic arm which operates the laparoscope, to the robots Zeus and da Vinci, robotic assistance in gynaecological endoscopic surgery has continuously evolved for the last fifteen years or so. It has brought about new technical advancements: the last generation robots offer a steady three-dimensional image, improved instrument dexterity and precision, higher ergonomics and comfort for the surgeon. The da Vinci robotic system has been used without evincing any specific morbidity in various cases, notably for tubal reanastomosis, myomectomy, hysterectomy, pelvic and para-aortic lymphadenectomy or sacrocolpopexy amongst others. Robotic assistance in gynaecology is thus feasible. Like conventional laparoscopic surgery, it allows decreased blood loss and morbidity as well as shorter hospital stay, as compared to laparotomy. It might indeed allow many surgical teams to perform minimally invasive surgical procedures which they were not used to performing by laparoscopy. Randomized prospective studies are needed to define its indications more precisely. Besides, its medico-financial impact should be evaluated too.

  14. Robot-assisted surgery in gynecological oncology

    DEFF Research Database (Denmark)

    Kristensen, Steffen E; Mosgaard, Berit J; Rosendahl, Mikkel

    2017-01-01

    INTRODUCTION: Robot-assisted surgery has become more widespread in gynecological oncology. The purpose of this systematic review is to present current knowledge on robot-assisted surgery, and to clarify and discuss controversies that have arisen alongside the development and deployment. MATERIAL...... was performed by screening of titles and abstracts, and by full text scrutiny. From 2001 to 2016, a total of 76 references were included. RESULTS: Robot-assisted surgery in gynecological oncology has increased, and current knowledge supports that the oncological safety is similar, compared with previous...

  15. Stepwise introduction of laparoscopic liver surgery: validation of guideline recommendations.

    Science.gov (United States)

    van der Poel, Marcel J; Huisman, Floor; Busch, Olivier R; Abu Hilal, Mohammad; van Gulik, Thomas M; Tanis, Pieter J; Besselink, Marc G

    2017-10-01

    Uncontrolled introduction of laparoscopic liver surgery (LLS) could compromise postoperative outcomes. A stepwise introduction of LLS combined with structured training is advised. This study aimed to evaluate the impact of such a stepwise introduction. A retrospective, single-center case series assessing short term outcomes of all consecutive LLS in the period November 2006-January 2017. The technique was implemented in a stepwise fashion. To evaluate the impact of this stepwise approach combined with structured training, outcomes of LLS before and after a laparoscopic HPB fellowship were compared. A total of 135 laparoscopic resections were performed. Overall conversion rate was 4% (n = 5), clinically relevant complication rate 13% (n = 18) and mortality 0.7% (n = 1). A significant increase in patients with major LLS, multiple liver resections, previous abdominal surgery, malignancies and lesions located in posterior segments was observed after the fellowship as well as a decrease in the use of hand-assistance. Increasing complexity in the post fellowship period was reflected by an increase in operating times, but without comprising other surgical outcomes. A stepwise introduction of LLS combined with structured training reduced the clinical impact of the learning curve, thereby confirming guideline recommendations. Copyright © 2017 International Hepato-Pancreato-Biliary Association Inc. Published by Elsevier Ltd. All rights reserved.

  16. Localization of liver tumors in freehand 3D laparoscopic ultrasound

    Science.gov (United States)

    Shahin, O.; Martens, V.; Besirevic, A.; Kleemann, M.; Schlaefer, A.

    2012-02-01

    The aim of minimally invasive laparoscopic liver interventions is to completely resect or ablate tumors while minimizing the trauma caused by the operation. However, restrictions such as limited field of view and reduced depth perception can hinder the surgeon's capabilities to precisely localize the tumor. Typically, preoperative data is acquired to find the tumor(s) and plan the surgery. Nevertheless, determining the precise position of the tumor is required, not only before but also during the operation. The standard use of ultrasound in hepatic surgery is to explore the liver and identify tumors. Meanwhile, the surgeon mentally builds a 3D context to localize tumors. This work aims to upgrade the use of ultrasound in laparoscopic liver surgery. We propose an approach to segment and localize tumors intra-operatively in 3D ultrasound. We reconstruct a 3D laparoscopic ultrasound volume containing a tumor. The 3D image is then preprocessed and semi-automatically segmented using a level set algorithm. During the surgery, for each subsequent reconstructed volume, a fast update of the tumor position is accomplished via registration using the previously segmented and localized tumor as a prior knowledge. The approach was tested on a liver phantom with artificial tumors. The tumors were localized in approximately two seconds with a mean error of less than 0.5 mm. The strengths of this technique are that it can be performed intra-operatively, it helps the surgeon to accurately determine the location, shape and volume of the tumor, and it is repeatable throughout the operation.

  17. Cost of New Technologies in Prostate Cancer Treatment: Systematic Review of Costs and Cost Effectiveness of Robotic-assisted Laparoscopic Prostatectomy, Intensity-modulated Radiotherapy, and Proton Beam Therapy.

    Science.gov (United States)

    Schroeck, Florian Rudolf; Jacobs, Bruce L; Bhayani, Sam B; Nguyen, Paul L; Penson, David; Hu, Jim

    2017-11-01

    Some of the high costs of robot-assisted radical prostatectomy (RARP), intensity-modulated radiotherapy (IMRT), and proton beam therapy may be offset by better outcomes or less resource use during the treatment episode. To systematically review the literature to identify the key economic trade-offs implicit in a particular treatment choice for prostate cancer. We systematically reviewed the literature according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) statement and protocol. We searched Medline, Embase, and Web of Science for articles published between January 2001 and July 2016, which compared the treatment costs of RARP, IMRT, or proton beam therapy to the standard treatment. We identified 37, nine, and three studies, respectively. RARP is costlier than radical retropubic prostatectomy for hospitals and payers. However, RARP has the potential for a moderate cost advantage for payers and society over a longer time horizon when optimal cancer and quality-of-life outcomes are achieved. IMRT is more expensive from a payer's perspective compared with three-dimensional conformal radiotherapy, but also more cost effective when defined by an incremental cost effectiveness ratio new versus traditional technologies is costlier. However, given the low quality of evidence and the inconsistencies across studies, the precise difference in costs remains unclear. Attempts to estimate whether this increased cost is worth the expense are hampered by the uncertainty surrounding improvements in outcomes, such as cancer control and side effects of treatment. If the new technologies can consistently achieve better outcomes, then they may be cost effective. We review the cost and cost effectiveness of robot-assisted radical prostatectomy, intensity-modulated radiotherapy, and proton beam therapy in prostate cancer treatment. These technologies are costlier than their traditional counterparts. It remains unclear whether their use is associated

  18. Laparoscopic Versus Open Resection for Colorectal Liver Metastases: The OSLO-COMET Randomized Controlled Trial.

    Science.gov (United States)

    Fretland, Åsmund Avdem; Dagenborg, Vegar Johansen; Bjørnelv, Gudrun Maria Waaler; Kazaryan, Airazat M; Kristiansen, Ronny; Fagerland, Morten Wang; Hausken, John; Tønnessen, Tor Inge; Abildgaard, Andreas; Barkhatov, Leonid; Yaqub, Sheraz; Røsok, Bård I; Bjørnbeth, Bjørn Atle; Andersen, Marit Helen; Flatmark, Kjersti; Aas, Eline; Edwin, Bjørn

    2018-02-01

    To perform the first randomized controlled trial to compare laparoscopic and open liver resection. Laparoscopic liver resection is increasingly used for the surgical treatment of liver tumors. However, high-level evidence to conclude that laparoscopic liver resection is superior to open liver resection is lacking. Explanatory, assessor-blinded, single center, randomized superiority trial recruiting patients from Oslo University Hospital, Oslo, Norway from February 2012 to January 2016. A total of 280 patients with resectable liver metastases from colorectal cancer were randomly assigned to undergo laparoscopic (n = 133) or open (n = 147) parenchyma-sparing liver resection. The primary outcome was postoperative complications within 30 days (Accordion grade 2 or higher). Secondary outcomes included cost-effectiveness, postoperative hospital stay, blood loss, operation time, and resection margins. The postoperative complication rate was 19% in the laparoscopic-surgery group and 31% in the open-surgery group (12 percentage points difference [95% confidence interval 1.67-21.8; P = 0.021]). The postoperative hospital stay was shorter for laparoscopic surgery (53 vs 96 hours, P < 0.001), whereas there were no differences in blood loss, operation time, and resection margins. Mortality at 90 days did not differ significantly from the laparoscopic group (0 patients) to the open group (1 patient). In a 4-month perspective, the costs were equal, whereas patients in the laparoscopic-surgery group gained 0.011 quality-adjusted life years compared to patients in the open-surgery group (P = 0.001). In patients undergoing parenchyma-sparing liver resection for colorectal metastases, laparoscopic surgery was associated with significantly less postoperative complications compared to open surgery. Laparoscopic resection was cost-effective compared to open resection with a 67% probability. The rate of free resection margins was the same in both groups. Our results support the continued

  19. Single incision laparoscopic liver resection (SILL – a systematic review

    Directory of Open Access Journals (Sweden)

    Benzing, Christian

    2015-12-01

    Full Text Available Background: Today, minimally invasive liver resections for both benign and malignant tumors are routinely performed. Recently, some authors have described single incision laparoscopic liver resection (SILL procedures. Since SILL is a relatively young branch of laparoscopy, we performed a systematic review of the current literature to collect data on feasibility, perioperative results and oncological outcome.Methods: A literature research was performed on Medline for all studies that met the eligibility criteria. Titles and abstracts were screened by two authors independently. A study was included for review if consensus was obtained by discussion between the authors on the basis of predefined inclusion criteria. A thorough quality assessment of all included studies was performed. Data were analyzed and tabulated according to predefined outcome measures. Synthesis of the results was achieved by narrative review. Results: A total of 15 eligible studies were identified among which there was one prospective cohort study and one randomized controlled trial comparing SILL to multi incision laparoscopic liver resection (MILL. The rest were retrospective case series with a maximum of 24 patients. All studies demonstrated convincing results with regards to feasibility, morbidity and mortality. The rate of wound complications and incisional hernia was low. The cosmetic results were good.Conclusions: This is the first systematic review on SILL including prospective trials. The results of the existing studies reporting on SILL are favorable. However, a large body of scientific evidence on the field of SILL is missing, further randomized controlled studies are urgently needed.

  20. Robot-assisted pyeloplasty: review of the current literature, technique and outcome.

    Science.gov (United States)

    Singh, Iqbal; Hemal, Ashok K

    2010-04-01

    To review the global select data on the current technique, perioperative outcome and literature on the robot-assisted pyeloplasty (RAP). The published English literature (PubMed) was extensively searched using the key words; robot, robot-assisted pyeloplasty, laparoscopy, laparoscopic pyeloplasty and ureteropelvic junction obstruction. The selected studies were then reviewed, tracked and analyzed in order to determine the current role, outcome and status of robot-assisted laparoscopic pyeloplasty. The search yielded about 25 published series on RAP comprising about 740 cases with a mean operative time, estimated blood loss, crossing vessel prevalence, hospital stay,perioperative complication rate and follow up duration of 194 min, 50 mL, 47%, 2.3 days, 6% and 14.9 months respectively. The initial peri-operative results and intermediate follow up of cases of repair of the ureteropelvic junction obstruction with robot-assisted pyeloplasty appear to be favorable and comparable to that of open pyeloplasty, while long term outcome data is still awaited. The da Vinci surgical robotic system is a promising surgical armamentarium in the hands of the modern day urologist for the minimally invasive definitive surgical management of both primary and secondary ureteropelvic junction obstruction.

  1. Robotic assisted surgery in pediatric gynecology: promising innovation in mini invasive surgical procedures.

    Science.gov (United States)

    Nakib, Ghassan; Calcaterra, Valeria; Scorletti, Federico; Romano, Piero; Goruppi, Ilaria; Mencherini, Simonetta; Avolio, Luigi; Pelizzo, Gloria

    2013-02-01

    Robotic assisted surgery is not yet widely applied in the pediatric field. We report our initial experience regarding the feasibility, safety, benefits, and limitations of robot-assisted surgery in pediatric gynecological patients. Descriptive, retrospective report of experience with pediatric gynecological patients over a period of 12 months. Department of Pediatric Surgery, IRCCS Policlinico San Matteo Foundation. Children and adolescents, with a surgical diagnosis of ovarian and/or tubal lesions. Robot assembly time and operative time, days of hospitalization, time to cessation of pain medication, complication rate, conversion rate to laparoscopic procedure and trocar insertion strategy. Six children and adolescents (2.4-15 yrs), weighing 12-55 kg, underwent robotic assisted surgery for adnexal pathologies: 2 for ovarian cystectomy, 2 for oophorectomy, 1 for right oophorectomy and left salpingo-oophorectomy for gonadal disgenesis, 1 for exploration for suspected pelvic malformation. Mean operative time was 117.5 ± 34.9 minutes. Conversion to laparatomy was not necessary in any of the cases. No intra- or postoperative complications occurred. Initial results indicate that robotic assisted surgery is safely applicable in the pediatric gynecological population, although it is still premature to conclude that it provides better clinical outcomes than traditional laparoscopic surgery. Randomized, prospective, comparative studies will help characterize the advantages and disadvantages of this new technology in pediatric patients. Copyright © 2013 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  2. Robot-assisted gastroesophageal surgery: usefulness and limitations.

    Science.gov (United States)

    Diez Del Val, Ismael; Martinez Blazquez, Cándido; Loureiro Gonzalez, Carlos; Vitores Lopez, Jose Maria; Sierra Esteban, Valentin; Barrenetxea Asua, Julen; Del Hoyo Aretxabala, Izaskun; Perez de Villarreal, Patricia; Bilbao Axpe, Jose Esteban; Mendez Martin, Jaime Jesus

    2014-06-01

    Robot-assisted surgery overcomes some of the limitations of traditional laparoscopic surgery. We present our experience and lessons learned in two surgical units dedicated to gastro-esophageal surgery. From June 2009 to January 2013, we performed 130 robot-assisted gastroesophageal procedures, including Nissen fundoplication (29), paraesophageal hernia repair (18), redo for failed antireflux surgery (11), esophagectomy (19), subtotal (5) or wedge (4) gastrectomy, Heller myotomy for achalasia (22), gastric bypass for morbid obesity (12), thoracoscopic leiomyomectomy (4), Morgagni hernia repair (3), lower-third esophageal diverticulectomy (1) and two diagnostic procedures. There were 80 men and 50 women with a median age of 54 years (interquartile range: 46-65). Ten patients (7.7 %) had severe postoperative complications: eight after esophagectomy (three leaks-two cervical and one thoracic-managed conservatively), one stapler failure, one chylothorax, one case of gastric migration to the thorax, one case of biliary peritonitis, and one patient with a transient ventricular dyskinesia. One redo procedure needed reoperation because of port-site bleeding, and one patient died of pulmonary complications after a giant paraesophageal hernia repair; 30-day mortality was, therefore, 0.8 %. There were six elective and one forced conversions (hemorrhage), so total conversion was 5.4 %. Median length of stay was 4 days (IQ range 3-7). Robot-assisted gastroesophageal surgery is feasible and safe, and may be applied to most common procedures. It seems of particular value for Heller myotomy, large paraesophageal hernias, redo antireflux surgery, transhiatal dissection, and hand-sewn intrathoracic anastomosis.

  3. [The advantages of implementing an e-learning platform for laparoscopic liver surgery].

    Science.gov (United States)

    Furcea, L; Graur, F; Scurtu, L; Plitea, N; Pîslă, D; Vaida, C; Deteşan, O; Szilaghy, A; Neagoş, H; Mureşan, A; Vlad, L

    2011-01-01

    The rapid expansion of laparoscopic surgery has led to the development of training methods for acquiring technical skills. The importance and complexity of laparoscopic liver surgery are arguments for developing a new integrated system of teaching, learning and evaluation, based on modern educational principles, on flexibility allowing wide accessibility among surgeons. This paper presents the development of e-learning platform designed for training in laparoscopic liver surgery and pre-planning of the operation in a virtual environment. E-learning platform makes it possible to simulate laparoscopic liver surgery remotely via internet connection. The addressability of this e-learning platform is large, being represented by young surgeons who are mainly preoccupied by laparoscopic liver surgery, as well as experienced surgeons interested in obtaining a competence in the hepatic minimally invasive surgery.

  4. A systematic review on radiofrequency assisted laparoscopic liver resection: Challenges and window to excel.

    Science.gov (United States)

    Reccia, Isabella; Kumar, Jayant; Kusano, Tomokazu; Zanellato, Artur; Draz, Ahmed; Spalding, Duncan; Habib, Nagy; Pai, Madhava

    2017-09-01

    Laparoscopic liver resection has progressively gained acceptance as a safe and effective procedure in the treatment of benign and malignant liver neoplasms. However, blood loss remains the major challenge in liver surgery. Several techniques and devices have been introduced in liver surgery in order to minimize intraoperative haemorrhage during parenchymal transection. Radiofrequency (RF)-assisted liver resection has been shown to be an effective method to minimize bleeding in open and laparoscopic liver resection. A number of RF devices for parenchymal transection have been designed to assist laparoscopic liver resections. Here we have reviewed the results of various RF devices in laparoscopic liver resection. A total 15 article were considered relevant for the evaluation of technical aspects and outcomes of RF-assisted liver resections in laparoscopic procedures. In these studies, 176 patients had laparoscopic liver resection using RF-assisted parenchymal coagulation. Two monopolar and three bipolar devices were employed. Blood loss was limited in most of the studies. The need of blood transfusions was limited to two cases in all the series. Conversion was necessary due to bleeding in 3 cases. Operative and transection times varied between studies. However, RF-assisted resection with bipolar devices appeared to have taken less time in comparison to other RF devices. RF-related complications were minimum, and only one case of in-hospital death due to hepatic failure was reported. Although RF has been used in a small minority of laparoscopic liver resections, laparoscopic RF-assisted liver resection for benign and malignant disease is a safe and feasible procedure associated with reduction in blood loss, low morbidity, and lower hospital mortality rates. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Laparoscopic versus open 1-stage resection of synchronous liver metastases and primary colorectal cancer.

    Science.gov (United States)

    Gorgun, Emre; Yazici, Pinar; Onder, Akin; Benlice, Cigdem; Yigitbas, Hakan; Kahramangil, Bora; Tasci, Yunus; Aksoy, Erol; Aucejo, Federico; Quintini, Cristiano; Miller, Charles; Berber, Eren

    2017-08-01

    The aim of this study is to compare the perioperative and oncologic outcomes of open and laparoscopic approaches for concomitant resection of synchronous colorectal cancer and liver metastases. Between 2006 and 2015, all patients undergoing combined resection of primary colorectal cancer and liver metastases were included in the study (n=43). Laparoscopic and open groups were compared regarding clinical, perioperative and oncologic outcomes. There were 29 patients in the open group and 14 patients in the laparoscopic group. The groups were similar regarding demographics, comorbidities, histopathological characteristics of the primary tumor and liver metastases. Postoperative complication rate (44.8% vs . 7.1%, P=0.016) was higher, and hospital stay (10 vs . 6.4 days, P=0.001) longer in the open compared to the laparoscopic group. Overall survival (OS) was comparable between the groups (P=0.10); whereas, disease-free survival (DFS) was longer in laparoscopic group (P=0.02). According to the results, in patients, whose primary colorectal cancer and metastatic liver disease was amenable to a minimally invasive resection, a concomitant laparoscopic approach resulted in less morbidity without compromising oncologic outcomes. This suggests that a laparoscopic approach may be considered in appropriate patients by surgeons with experience in both advanced laparoscopic liver and colorectal techniques.

  6. Commentary on "Robot-assisted laparoscopic vs open radical cystectomy: Comparison of complications and perioperative oncological outcomes in 200 patients." Kader AK, Richards KA, Krane LS, Pettus JA, Smith JJ, Hemal AK, Division of Urology, UC San Diego Health System, San Diego, CA.: BJU Int 2013; 112(4):E290-4. doi:10.1111/bju.12167. [Epub 2013 Jul 1].

    Science.gov (United States)

    See, William A

    2014-11-01

    To compare perioperative morbidity and oncological outcomes of robot-assisted laparoscopic radical cystectomy (RARC) to open RC (ORC) at a single institution. A retrospective analysis was performed on a consecutive series of patients undergoing RC (100 RARC and 100 ORC) at Wake Forest University with curative intent from 2006 until 2010. Complication data using the Clavien system were collected for 90 days postoperatively. Complications and other perioperative outcomes were compared between patient groups. Patients in both groups had comparable preoperative characteristics. The overall and major complication (Clavien ≥ 3) rates were lower for RARC patients at 35 vs 57% (P = 0.001) and 10 vs 22% (P = 0.019), respectively. There were no significant differences between groups for pathological outcomes, including stage, number of nodes harvested or positive margin rates. Our data suggest that patients undergoing RARC have perioperative oncological outcomes comparable with ORC, with fewer overall or major complications. Definitive claims about comparative outcomes with RARC require results from larger, randomised controlled trials. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Robotic assisted minimally invasive surgery

    Directory of Open Access Journals (Sweden)

    Palep Jaydeep

    2009-01-01

    Full Text Available The term "robot" was coined by the Czech playright Karel Capek in 1921 in his play Rossom′s Universal Robots. The word "robot" is from the check word robota which means forced labor.The era of robots in surgery commenced in 1994 when the first AESOP (voice controlled camera holder prototype robot was used clinically in 1993 and then marketed as the first surgical robot ever in 1994 by the US FDA. Since then many robot prototypes like the Endoassist (Armstrong Healthcare Ltd., High Wycombe, Buck, UK, FIPS endoarm (Karlsruhe Research Center, Karlsruhe, Germany have been developed to add to the functions of the robot and try and increase its utility. Integrated Surgical Systems (now Intuitive Surgery, Inc. redesigned the SRI Green Telepresence Surgery system and created the daVinci Surgical System ® classified as a master-slave surgical system. It uses true 3-D visualization and EndoWrist ® . It was approved by FDA in July 2000 for general laparoscopic surgery, in November 2002 for mitral valve repair surgery. The da Vinci robot is currently being used in various fields such as urology, general surgery, gynecology, cardio-thoracic, pediatric and ENT surgery. It provides several advantages to conventional laparoscopy such as 3D vision, motion scaling, intuitive movements, visual immersion and tremor filtration. The advent of robotics has increased the use of minimally invasive surgery among laparoscopically naοve surgeons and expanded the repertoire of experienced surgeons to include more advanced and complex reconstructions.

  8. LAPAROSCOPIC LEFT LATERAL SECTIONECTOMY IN LIVING LIVER DONOR

    Directory of Open Access Journals (Sweden)

    S. V. Gautier

    2016-01-01

    Full Text Available Introduction. Living donor liver transplantation has proved to be an effective, safe and radical treatment modality for patients with end-stage liver diseases. Left lateral section (LLS of donor’s liver is used in pediatric recipients. Laparoscopic LLS procurement was fi rst described by D. Cherqui in 2002. At present, this technique is routinely used only by 5 hospitals in the world. However, up to date, some authors consider it to be a new standard to perform such a surgery in living donors.Aim. To analyze the fi rst Russian experience in laparoscopic left lateral sectionectomy (LapLLS in living related donor.Materials and methods. From May to September 2016 fi ve LapLLS were performed in living donors. In all cases donors were women (mothers in 4 cases and aunt in 1 case. Recipients were children aged from 6 months through 3 years with body mass from 5.6 to 12.5 kg. Liver transection was carried out under conditions of maintained blood supply. Parenchymal transection was performed using a harmonic scalpel, bipolar coagulation and ultrasound dissection.Results. Average donor age was 32 ± 5 years. Average operation time was 287 ± 16 min. Average LLS graft weight was 220 ± 16 g. Intraoperative blood loss did not exceed 100 ml (95 ± 5 ml. Donors were discharged on the 3rd–4th post-op day. There were no postoperative complications in donors. Recipients were also characterized by a standard course of the postoperative period.Conclusion. LapLLS is an effective and safe method with several advantages. Primarily, these are early rehabilitation of the donors and shortening of the hospital stay, which are important for the quick return to normal way of live. Excellent visualization of anatomical structures, including vascular and biliary ones, allows performing precise selection. In addition, good cosmetic effect is also an important aspect.

  9. Robot-assisted pyeloplasty for pelvi-ureteric junction obstruction of lower moiety in partial duplex system: A technical challenge

    Directory of Open Access Journals (Sweden)

    Girdhar S Bora

    2016-01-01

    Full Text Available Management of pelvi-ureteric junction obstruction (PUJO in a duplex system is technically challenging as dissection at the pelvis may jeopardize the vascularity of the normal moiety ureter. Anastomosing the pelvis to the one single ureter will have a risk of future development of stricture which then will risk both the moieties. Robotic assistance enables appropriate tissue dissection; minimal handling of normal ureter and precision in suturing, overcoming the potential challenges involved in the minimally invasive management of such complex cases. We report the feasibility and efficacy of robot-assisted laparoscopic pyeloplasty in such case.

  10. [Sacrocolpopexy - pro laparoscopic].

    Science.gov (United States)

    Hatzinger, M; Sohn, M

    2012-05-01

    Innovative techniques have a really magical attraction for physicians as well as for patients. The number of robotic-assisted procedures worldwide has almost tripled from 80,000 procedures in the year 2007 to 205,000 procedures in 2010. In the same time the total number of Da Vinci surgery systems sold climbed from 800 to 1,400. Advantages, such as three-dimensional visualization, a tremor-filter, an excellent instrument handling with 6 degrees of freedom and better ergonomics, together with aggressive marketing led to a veritable flood of new Da Vinci acquisitions in the whole world. Many just took the opportunity to introduce a new instrument to save a long learning curve and start immediately in the surgical master class.If Da Vinci sacrocolpopexy is compared with the conventional laparoscopic approach, robotic-assisted sacrocolpopexy shows a significantly longer duration of the procedure, a higher need for postoperative analgesics, much higher costs and an identical functional outcome without any advantage over the conventional laparoscopic approach. Although the use of robotic-assisted systems shows a significantly lower learning curve for laparoscopic beginners, it only shows minimal advantages for the experienced laparoscopic surgeon. Therefore it remains uncertain whether robotic-assisted surgery shows a significant advantage compared to the conventional laparoscopic surgery, especially with small reconstructive laparoscopic procedures such as sacrocolpopexy.

  11. Short-Term Outcomes of Simultaneous Laparoscopic Colectomy and Hepatectomy for Primary Colorectal Cancer With Synchronous Liver Metastases

    OpenAIRE

    Inoue, Akira; Uemura, Mamoru; Yamamoto, Hirofumi; Hiraki, Masayuki; Naito, Atsushi; Ogino, Takayuki; Nonaka, Ryoji; Nishimura, Junichi; Wada, Hiroshi; Hata, Taishi; Takemasa, Ichiro; Eguchi, Hidetoshi; Mizushima, Tsunekazu; Nagano, Hiroaki; Doki, Yuichiro

    2014-01-01

    Although simultaneous resection of primary colorectal cancer and synchronous liver metastases is reported to be safe and effective, the feasibility of a laparoscopic approach remains controversial. This study evaluated the safety, feasibility, and short-term outcomes of simultaneous laparoscopic surgery for primary colorectal cancer with synchronous liver metastases. From September 2008 to December 2013, 10 patients underwent simultaneous laparoscopic resection of primary colorectal cancer an...

  12. The effect of a multimodal fast-track programme on outcomes in laparoscopic liver surgery : a multicentre pilot study

    NARCIS (Netherlands)

    Stoot, Jan H.; van Dam, Ronald M.; Busch, Olivier R.; van Hillegersberg, Richard; De Boer, Marieke; Damink, Steven W. M. Olde; Bemelmans, Marc H.; Dejong, Cornelis H. C.

    Objectives: This study was conducted to evaluate the added value of an enhanced recovery after surgery (ERAS) programme in laparoscopic liver resections for solid tumours. Methods: Patients undergoing laparoscopic liver resection between July 2005 and July 2008 were included. Indications for

  13. Individualized laparoscopic B-ultrasound-guided microwave ablation for multifocal primary liver cancer.

    Science.gov (United States)

    Xu, Zhifeng; Yang, Zhangwei; Pan, Jianghua; Hu, Yiren

    2018-03-01

    Liver cancer is one of the most common malignancies of the digestive system. Minimally invasive ablation procedures have become one of the major means for treating unresectable multifocal liver cancer and have been extensively applied in primary and metastatic liver cancer treatment. Laparoscopic B-ultrasound-guided microwave ablation is an example of the progress made in this field. To analyze and summarize the results of and experience with laparoscopic B-ultrasound-guided microwave ablation for multifocal primary liver cancer; moreover, the ablation effects were compared between tumors of different sizes. Laparoscope-guided needle ablation was conducted on 84 lesions from 32 patients with primary liver cancer based on tumor size, quantity, and location. Moreover, the perioperative data, ablation effects according to tumor size, and long-term follow-up results were analyzed. Among the 84 nodules treated via microwave ablation, tumors measuring ≤ 3 cm demonstrated complete ablation upon imaging analysis conducted 1 month after surgery. Moreover, 5 of the tumors measuring > 3 cm demonstrated incomplete ablation. In these cases, a second procedure was performed, until imaging studies confirmed that complete ablation was achieved. Laparoscopic microwave ablation allows for precise puncture positioning, an effective ablation range, and safe and feasible surgery, which is especially suitable for liver tumors located in sites difficult to access.

  14. ACOG Technology Assessment in Obstetrics and Gynecology No. 6: Robot-assisted surgery.

    Science.gov (United States)

    2009-11-01

    The field of robotic surgery is developing rapidly, but experience with this technology is currently limited. In response to increasing interest in robotics technology, the Committee on Gynecologic Practice's Technology Assessment was developed to describe the robotic surgical system,potential advantages and disadvantages, gynecologic applications, and the current state of the evidence. Randomized trials comparing robot-assisted surgery with traditional laparoscopic, vaginal, or abdominal surgery are needed to evaluate long-term clinical outcomes and cost-effectiveness, as well as to identify the best applications of this technology.

  15. Single-port laparoscopic approach of the left liver: initial experience.

    Science.gov (United States)

    Camps Lasa, Judith; Cugat Andorrà, Esteban; Herrero Fonollosa, Eric; García Domingo, María Isabel; Sánchez Martínez, Raquel; Vargas Pierola, Harold; Rodríguez Campos, Aurora

    2014-11-01

    New technological advances have enabled the development of single-port laparoscopic surgery. This approach began with cholecystectomy and subsequently with other abdominal surgeries. However, few publications on laparoscopic liver surgery have described the use of complete single-port access. We present our initial experience of a single-port laparoscopic hepatectomy. Between May 2012 and December 2013, 5 single-port laparoscopic hepatectomies were performed: one for benign disease and four for colorectal liver metastases. The lesions were approached through a 3-5 cm right supraumbilical incision using a single-port access device. All the lesions were located in hepatic segments II or III. Four left lateral sectorectomies and one left hepatectomy were performed. Median operative time was 135 min. No cases were converted to conventional laparoscopic or open surgery. The oral intake began at 18 h. There were no postoperative complications and no patients required blood transfusion. The median hospital stay was 3 days. The degree of satisfaction was very good in 4 cases and good in one. Patients resumed their normal daily activities at 8 days. Single-port laparoscopic hepatectomy is safe and feasible in selected cases and may reduce surgical aggression and offer better cosmetic results. Comparative studies are needed to determine the real advantages of this approach. Copyright © 2014 AEC. Published by Elsevier Espana. All rights reserved.

  16. [Two Cases of Laparoscopic Resection of Colon Cancer Manifested by Liver Abscess].

    Science.gov (United States)

    Ohashi, Motonari; Iwama, Masahiro; Ikenaga, Shojirokazunori; Yokoyama, Makoto

    2017-11-01

    We report 2 cases of laparoscopic surgery for patients who had liver abscess as the initial manifestation of underlying colon cancer. The first case was in an 80-year-old woman who presented to our hospital with a diagnosis ofliver abscess. Percutaneous transhepatic abscess drainage(PTAD)was performed as initial treatment. Subsequent colonoscopy revealed a type 1 tumor in the cecum, and biopsy results ofthe mass indicated adenocarcinoma. The patient underwent laparoscopic right hemicolectomy as curative treatment. The pathological findings were as follows: tub1, T2, N0, M0 and Stage I . Two years later, she remains disease free. The second case was in a 59-year-old man with liver abscess. Colonoscopy also revealed a type 2 tumor in the sigmoid colon. After treatment of the liver abscess with PTAD, laparoscopic sigmoidectomy was performed with a preoperative diagnosis of sigmoid colon cancer. The pathological findings were as follows: tub2, T3, N0, M0 and Stage II . Lung metastases appeared 10 months after surgery, and systemic chemotherapy was administered. In conclusion, liver abscess is occasionally caused by malignancy, and complete gastrointestinal evaluation should be conducted. Laparoscopic radical surgery can be safely performed in cases in which the liver abscesses are controlled.

  17. Effects of realistic force feedback in a robotic assisted minimally invasive surgery system.

    Science.gov (United States)

    Moradi Dalvand, Mohsen; Shirinzadeh, Bijan; Nahavandi, Saeid; Smith, Julian

    2014-06-01

    Robotic assisted minimally invasive surgery systems not only have the advantages of traditional laparoscopic procedures but also restore the surgeon's hand-eye coordination and improve the surgeon's precision by filtering hand tremors. Unfortunately, these benefits have come at the expense of the surgeon's ability to feel. Several research efforts have already attempted to restore this feature and study the effects of force feedback in robotic systems. The proposed methods and studies have some shortcomings. The main focus of this research is to overcome some of these limitations and to study the effects of force feedback in palpation in a more realistic fashion. A parallel robot assisted minimally invasive surgery system (PRAMiSS) with force feedback capabilities was employed to study the effects of realistic force feedback in palpation of artificial tissue samples. PRAMiSS is capable of actually measuring the tip/tissue interaction forces directly from the surgery site. Four sets of experiments using only vision feedback, only force feedback, simultaneous force and vision feedback and direct manipulation were conducted to evaluate the role of sensory feedback from sideways tip/tissue interaction forces with a scale factor of 100% in characterising tissues of varying stiffness. Twenty human subjects were involved in the experiments for at least 1440 trials. Friedman and Wilcoxon signed-rank tests were employed to statistically analyse the experimental results. Providing realistic force feedback in robotic assisted surgery systems improves the quality of tissue characterization procedures. Force feedback capability also increases the certainty of characterizing soft tissues compared with direct palpation using the lateral sides of index fingers. The force feedback capability can improve the quality of palpation and characterization of soft tissues of varying stiffness by restoring sense of touch in robotic assisted minimally invasive surgery operations.

  18. Virtual tutor systems for robot-assisted instruction

    Science.gov (United States)

    Zhao, Zhijing; Zhao, Deyu; Zhang, Zizhen; Wei, Yongji; Qi, Bingchen; Okawa, Yoshikuni

    2004-03-01

    Virtual Reality technology belongs to advanced computer technology, it has been applied in instruction field and gains obvious effect. At the same time, robot assisted instruction comes true with the continuous development of Robot technology and artificial intelligence technology. This paper introduces a virtual tutor system for robot assisted instruction.

  19. Robot-assisted radical prostatectomy is a safe procedure

    DEFF Research Database (Denmark)

    Thomsen, Frederik Birkebæk; Berg, Kasper Drimer; Hvarness, Helle

    2013-01-01

    We present our departmental experience with robot-assisted radical prostatectomy and describe complications and early results for the first 239 consecutive patients.......We present our departmental experience with robot-assisted radical prostatectomy and describe complications and early results for the first 239 consecutive patients....

  20. Hand-assisted laparoscopic liver resection using Habib's technique: early experience.

    Science.gov (United States)

    Vávra, Petr; Ihnat, Peter; Vavrova, Michaela; Martinek, Lubomir; Dostalik, Jan; Habib, Nagy

    2012-03-01

    Hand-assisted laparoscopic liver surgery, a newly developed technique based on an innovative concept, has proved useful and safe for a variety of less invasive hepatectomies. Radiofrequency-assisted hepatic resection has been reported to be safe, associated with minimal morbidity and mortality and decreased intraoperative blood loss and transfusion requirements. We describe how we perform hand-assisted laparoscopic radiofrequency-assisted hepatic resection using a bipolar radiofrequency device. The use of the hand port has allowed the surgeon to use his hand in direct liver manipulation, mobilization, and retraction. It was also useful for tactile tumour localization. Radiofrequency-assisted hepatic parenchymal transection was performed on 15 patients using a bipolar device (Habib 4X) with minimal blood loss (74 ml), and very decent operative and resection times (92 min, 33 min respectively). This combined procedure offers a safe, effective and rapid liver resection technique. This might encourage surgeons to perform a minimally invasive approach for liver resection more frequently.

  1. Laparoscopic liver resection: wedge resections to living donor hepatectomy, are we heading in the right direction?

    Science.gov (United States)

    Cherian, P Thomas; Mishra, Ashish Kumar; Kumar, Palaniappen; Sachan, Vijayant Kumar; Bharathan, Anand; Srikanth, Gadiyaram; Senadhipan, Baiju; Rela, Mohamad S

    2014-10-07

    Despite inception over 15 years ago and over 3000 completed procedures, laparoscopic liver resection has remained mainly in the domain of selected centers and enthusiasts. Requirement of extensive open liver resection (OLR) experience, in-depth understanding of anatomy and considerable laparoscopic technical expertise may have delayed wide application. However healthy scepticism of its actual benefits and presence of a potential publication bias; concern about its safety and technical learning curve, are probably equally responsible. Given that a large proportion of our work, at least in transplantation is still OLR, we have attempted to provide an entirely unbiased, mature opinion of its pros and cons in the current invited review. We have divided this review into two sections as we believe they merit separate attention on technical and ethical grounds. The first part deals with laparoscopic liver resection (LLR) in patients who present with benign or malignant liver pathology, wherein we have discussed its overall outcomes; its feasibility based on type of pathology and type of resection and included a small section on application of LLR in special scenarios like cirrhosis. The second part deals with the laparoscopic living donor hepatectomy (LDH) experience to date, including its potential impact on transplantation in general. Donor safety, graft outcomes after LDH and criterion to select ideal donors for LLR are discussed. Within each section we have provided practical points to improve safety in LLR and attempted to reach reasonable recommendations on the utilization of LLR for units that wish to develop such a service.

  2. Retention of robot-assisted surgical skills in urological surgeons acquired using Mimic dV-Trainer.

    Science.gov (United States)

    Teishima, Jun; Hattori, Minoru; Inoue, Shogo; Ikeda, Kenichiro; Hieda, Keisuke; Ohara, Shinya; Egi, Hiroyuki; Ohdan, Hideki; Matsubara, Akio

    2014-07-01

    We assess the retention of robot-assisted surgical skills among urologic surgeons. The robot-assisted surgery skills of 20 urologic surgeons were assessed using a Mimic dV-Trainer program (Mimic Technologies, Inc., Seattle, WA) consisting of 6 tasks. These 20 surgeons had no previous experience either using the Mimic dV-Trainer or acting as the main surgeon in robot-assisted surgery. The surgeons completed the program 4 times in a row; after 1 year, they completed it again for a fifth time. Performance scores were recorded using the Mimic dV-Trainer's built-in algorithm. For all 6 tasks, there were significant improvements to the scores in the fourth trials compared with those in the first trials. The scores in the fifth trials did not significantly decline compared with those in the fourth trials. There was no significant difference between the fifth trial scores of surgeons with laparoscopic surgery skills/experience and those without. Our results indicate that fundamental robot-assisted surgical skills can be retained in the long-term after they are acquired.

  3. An Informationally Structured Room for Robotic Assistance

    Directory of Open Access Journals (Sweden)

    Tokuo Tsuji

    2015-04-01

    Full Text Available The application of assistive technologies for elderly people is one of the most promising and interesting scenarios for intelligent technologies in the present and near future. Moreover, the improvement of the quality of life for the elderly is one of the first priorities in modern countries and societies. In this work, we present an informationally structured room that is aimed at supporting the daily life activities of elderly people. This room integrates different sensor modalities in a natural and non-invasive way inside the environment. The information gathered by the sensors is processed and sent to a centralized management system, which makes it available to a service robot assisting the people. One important restriction of our intelligent room is reducing as much as possible any interference with daily activities. Finally, this paper presents several experiments and situations using our intelligent environment in cooperation with our service robot.

  4. A clinical study of the LiVac laparoscopic liver retractor system.

    Science.gov (United States)

    Gan, Philip; Bingham, Judy

    2016-02-01

    All retractors for laparoscopic operations on the gallbladder or stomach apply an upward force to the under-surface of the liver or gallbladder, most requiring an additional skin incision. The LiVac laparoscopic liver retractor system (LiVac retractor) comprises a soft silicone ring attached to suction tubing and connected to a regulated source of suction. The suction tubing extends alongside existing ports. When placed between the liver and diaphragm, and suction applied, a vacuum is created within the ring, keeping these in apposition. Following successful proof-of-concept animal testing, a clinical study was conducted to evaluate the performance and safety of the retractor in patients. The study was a dual-centre, single-surgeon, open-label study and recruited ten patients scheduled to undergo routine upper abdominal laparoscopic surgery including cholecystectomy, primary gastric banding surgery or fundoplication. The study was conducted at two sites and was approved by the institutions' ethics committees. The primary objective of the study was to evaluate the performance of the LiVac retractor in patients undergoing upper abdominal single- or multi-port laparoscopic surgery. Performance was measured by the attainment of milestones for the retractor and accessory bevel, where used, and safety outcomes through the recording of adverse events, physical parameters, pain scales, blood tests and a post-operative liver ultrasound. The LiVac retractor achieved both primary and secondary performance and safety objectives in all patients. No serious adverse events and no device-related adverse events or device deficiencies were reported. The LiVac retractor achieved effective liver retraction without clinically significant trauma and has potential application in multi- or single-port laparoscopic upper abdominal surgery. As a separate incision is not required, the use of the LiVac retractor in multi-port surgery therefore reduces the number of incisions.

  5. Technological advances in robotic-assisted laparoscopic surgery.

    Science.gov (United States)

    Tan, Gerald Y; Goel, Raj K; Kaouk, Jihad H; Tewari, Ashutosh K

    2009-05-01

    In this article, the authors describe the evolution of urologic robotic systems and the current state-of-the-art features and existing limitations of the da Vinci S HD System (Intuitive Surgical, Inc.). They then review promising innovations in scaling down the footprint of robotic platforms, the early experience with mobile miniaturized in vivo robots, advances in endoscopic navigation systems using augmented reality technologies and tracking devices, the emergence of technologies for robotic natural orifice transluminal endoscopic surgery and single-port surgery, advances in flexible robotics and haptics, the development of new virtual reality simulator training platforms compatible with the existing da Vinci system, and recent experiences with remote robotic surgery and telestration.

  6. Robotic-assisted laparoscopic hysterectomy for women with endometrial cancer

    DEFF Research Database (Denmark)

    Herling, Suzanne Forsyth; Møller, Ann M; Palle, Connie

    2017-01-01

    -anaesthesia care unit was shorter for patients undergoing RALH. CONCLUSIONS: RALH appears advantageous for women treated for endometrial cancer in terms of post-operative complications. We recommend the use of the Clavien-Dindo classification of surgical outcomes for quality assessment. FUNDING: departmental only...

  7. Robot-assisted laparoscopic skills development: formal versus informal training.

    Science.gov (United States)

    Benson, Aaron D; Kramer, Brandan A; Boehler, Margaret; Schwind, Cathy J; Schwartz, Bradley F

    2010-08-01

    The learning curve for robotic surgery is not completely defined, and ideal training components have not yet been identified. We attempted to determine whether skill development would be accelerated with formal, organized instruction in robotic surgical techniques versus informal practice alone. Forty-three medical students naive to robotic surgery were randomized into two groups and tested on three tasks using the robotic platform. Between the testing sessions, the students were given equally timed practice sessions. The formal training group participated in an organized, formal training session with instruction from an attending robotic surgeon, whereas the informal training group participated in an equally timed unstructured practice session with the robot. The results were compared based on technical score and time to completion of each task. There was no difference between groups in prepractice testing for any task. In postpractice testing, there was no difference between groups for the ring transfer tasks. However, for the suture placement and knot-tying task, the technical score of the formal training group was significantly better than that of the informal training group (p formal training may not be necessary for basic skills, formal instruction for more advanced skills, such as suture placement and knot tying, is important in developing skills needed for effective robotic surgery. These findings may be important in formulating potential skills labs or training courses for robotic surgery.

  8. Safety of laparoscopic resection for colorectal cancer in patients with liver cirrhosis: A retrospective cohort study.

    Science.gov (United States)

    Zhou, Senjun; Zhu, Hepan; Li, Zhenjun; Ying, Xiaojiang; Xu, Miaojun

    2018-05-26

    Patients with liver cirrhosis represent a high risk group for colorectal surgery. The safety and effectiveness of laparoscopy in colorectal surgery for cirrhotic patients is not clear. The aim of this study was to compare the outcomes of laparoscopic colorectal surgery with those of open procedure for colorectal cancer in patients with liver cirrhosis. A total of 62 patients with cirrhosis who underwent radical resections for colorectal cancer from 2005 to 2014 were identified retrospectively from a prospective database according to the technique adopted (laparoscopic or open). Short- and long-term outcomes were compared between the two groups. Comparison of laparoscopic group and open group revealed no significant differences at baseline. In the laparoscopic group, the laparoscopic surgery was associated with reduced estimated blood loss (136 vs. 266 ml, p = 0.015), faster first flatus (3 vs. 4 days, p = 0.002) and shorter days to first oral intake (4 vs. 5 days, p = 0.033), but similar operative times (p = 0.856), number of retrieved lymph nodes (p = 0.400) or postoperative hospital stays (p = 0.170). Despite the similar incidence of overall complications between the two groups (50.0% vs. 68.8%, p = 0.133), we observed lower morbidities in laparoscopic group in terms of the rate of Grade II complication (20.0% vs. 50.0%, p = 0.014). Long-term of overall and Disease-free survival rates did not differ between the two groups. Laparoscopic colorectal surgery appears to be a safe and less invasive alternative to open surgery in some elective cirrhotic patients in terms of less blood loss or early recovery and does not result in additional harm in terms of the postoperative complications or long-term oncological outcomes. Copyright © 2018. Published by Elsevier Ltd.

  9. A multimodal imaging framework for enhanced robot-assisted partial nephrectomy guidance

    Science.gov (United States)

    Halter, Ryan J.; Wu, Xiaotian; Hartov, Alex; Seigne, John; Khan, Shadab

    2015-03-01

    Robot-assisted laparoscopic partial nephrectomies (RALPN) are performed to treat patients with locally confined renal carcinoma. There are well-documented benefits to performing partial (opposed to radical) kidney resections and to using robot-assisted laparoscopic (opposed to open) approaches. However, there are challenges in identifying tumor margins and critical benign structures including blood vessels and collecting systems during current RALPN procedures. The primary objective of this effort is to couple multiple image and data streams together to augment visual information currently provided to surgeons performing RALPN and ultimately ensure complete tumor resection and minimal damage to functional structures (i.e. renal vasculature and collecting systems). To meet this challenge we have developed a framework and performed initial feasibility experiments to couple pre-operative high-resolution anatomic images with intraoperative MRI, ultrasound (US) and optical-based surface mapping and kidney tracking. With these registered images and data streams, we aim to overlay the high-resolution contrast-enhanced anatomic (CT or MR) images onto the surgeon's view screen for enhanced guidance. To date we have integrated the following components of our framework: 1) a method for tracking an intraoperative US probe to extract the kidney surface and a set of embedded kidney markers, 2) a method for co-registering intraoperative US scans with pre-operative MR scans, and 3) a method for deforming pre-op scans to match intraoperative scans. These components have been evaluated through phantom studies to demonstrate protocol feasibility.

  10. Initial Experiences of Simultaneous Laparoscopic Resection of Colorectal Cancer and Liver Metastases

    Directory of Open Access Journals (Sweden)

    L. T. Hoekstra

    2012-01-01

    Full Text Available Introduction. Simultaneous resection of primary colorectal carcinoma (CRC and synchronous liver metastases (SLMs is subject of debate with respect to morbidity in comparison to staged resection. The aim of this study was to evaluate our initial experience with this approach. Methods. Five patients with primary CRC and a clinical diagnosis of SLM underwent combined laparoscopic colorectal and liver surgery. Patient and tumor characteristics, operative variables, and postoperative outcomes were evaluated retrospectively. Results. The primary tumor was located in the colon in two patients and in the rectum in three patients. The SLM was solitary in four patients and multiple in the remaining patient. Surgical approach was total laparoscopic (2 patients or hand-assisted laparoscopic (3 patients. The midline umbilical or transverse suprapubic incision created for the hand port and/or extraction of the specimen varied between 5 and 10 cm. Median operation time was 303 (range 151–384 minutes with a total blood loss of 700 (range 200–850 mL. Postoperative hospital stay was 5, 5, 9, 14, and 30 days. An R0 resection was achieved in all patients. Conclusions. From this initial single-center experience, simultaneous laparoscopic colorectal and liver resection appears to be feasible in selected patients with CRC and SLM, with satisfying short-term results.

  11. Short-Term Outcomes of Simultaneous Laparoscopic Colectomy and Hepatectomy for Primary Colorectal Cancer With Synchronous Liver Metastases

    Science.gov (United States)

    Inoue, Akira; Uemura, Mamoru; Yamamoto, Hirofumi; Hiraki, Masayuki; Naito, Atsushi; Ogino, Takayuki; Nonaka, Ryoji; Nishimura, Junichi; Wada, Hiroshi; Hata, Taishi; Takemasa, Ichiro; Eguchi, Hidetoshi; Mizushima, Tsunekazu; Nagano, Hiroaki; Doki, Yuichiro; Mori, Masaki

    2014-01-01

    Although simultaneous resection of primary colorectal cancer and synchronous liver metastases is reported to be safe and effective, the feasibility of a laparoscopic approach remains controversial. This study evaluated the safety, feasibility, and short-term outcomes of simultaneous laparoscopic surgery for primary colorectal cancer with synchronous liver metastases. From September 2008 to December 2013, 10 patients underwent simultaneous laparoscopic resection of primary colorectal cancer and synchronous liver metastases with curative intent at our institute. The median operative time was 452 minutes, and the median estimated blood loss was 245 mL. Median times to discharge from the hospital and adjuvant chemotherapy were 13.5 and 44 postoperative days, respectively. Negative resection margins were achieved in all cases, with no postoperative mortality or major morbidity. Simultaneous laparoscopic colectomy and hepatectomy for primary colorectal cancer with synchronous liver metastases appears feasible with low morbidity and favorable outcomes. PMID:25058762

  12. Consumerism and its impact on robotic-assisted radical prostatectomy.

    Science.gov (United States)

    Alkhateeb, Sultan; Lawrentschuk, Nathan

    2011-12-01

    • Many experts consider that media coverage, marketing and/or direct-to-consumer advertising, particularly Internet-based forms, are fundamental to the widespread adoption of robotic-assisted prostatectomy (RARP). However, this has not been explored previously. • The primary objective of the present study was to delineate the role of media coverage and marketing of RARP on the Internet, whereas the secondary goal focused on website quality with respect to the presentation of prostatectomy. • Website content was evaluated for direct-to-consumer advertising after the retrieval of the first 50 websites using Google and Yahoo for each of the terms: 'robotic prostatectomy, laparoscopic prostatectomy (LP) and open radical prostatectomy (ORP)'. • A linear regression analysis was performed for the annual number of Internet news hits over the last decade for each procedure. Website quality assessment was performed using WHO Honesty on the Internet (HON) code principles. • Of the retrieved sites, the proportion containing direct-to-consumer advertising for RARP vs LP vs ORP using Google was 64% vs 14% vs 0%, respectively (P 0.05). • Media coverage and marketing of RARP on the Internet is more widespread compared to LP and ORP. • Disturbingly, the quality of websites using any technique for prostatectomy was of poor quality when using principles of honest information presenting and such findings need to be discussed with respect to obtaining informed consent from patients. © 2011 THE AUTHORS. BJU INTERNATIONAL © 2011 BJU INTERNATIONAL.

  13. Evaluation of robotic-assisted platysmaplasty procedures in a cadaveric model using the da Vinci Surgical System.

    Science.gov (United States)

    Taghizadeh, Farhan; Reiley, Carol; Mohr, Catherine; Paul, Malcolm

    2014-03-01

    We are evaluating the technical feasibility of robotic-assisted laparoscopic vertical-intermediate platysmaplasty in conjunction with an open rhytidectomy. In a cadaveric study, the da Vinci Surgical System was used to access certain angles in the lower neck that are difficult for traditional short incision, short flap procedures. Ergonomics, approach, and technical challenges were noted. To date, there are no published reports of robotic-assisted neck lifts, motivating us to assess its potential in this field of plastic surgery. Standard open technique short flap rhytidectomies with concurrent experimental robotic-assisted platysmaplasties (neck lifts) were performed on six cadavers with the da Vinci Si Surgical System(®) (Intuitive Surgical, Sunnyvale, CA, USA). The surgical procedures were performed on a diverse cadaver population from June 2011 to January 2012. The procedures included (1) submental incision and laser-assisted liposuction, (2) open rhytidectomy, and (3) robotic-assisted platysmaplasty using knot-free sutures. A variety of sutures and fat extraction techniques, coupled with 0° and 30° three-dimensional endoscopes, were utilized to optimize visualization of the platysma. An unaltered da Vinci Si Surgical System with currently available instruments was easily adaptable to neck lift surgery. Mid-neck platysma exposure was excellent, tissue handling was delicate and precise, and suturing was easily performed. Robotic-assisted surgery has the potential to improve outcomes in neck lifts by offering the ability to manipulate instruments with increased freedom of movement, scaled motion, tremor reduction, and stereoscopic three-dimensional visualization in the deep neck. Future clinical studies on live human patients can better assess subject and surgeon benefits arising from the use of the da Vinci system for neck lifts. Evidence obtained from multiple time series with or without the intervention, such as case studies. Dramatic results in

  14. Robotically assisted MRgFUS system

    Science.gov (United States)

    Jenne, Jürgen W.; Krafft, Axel J.; Maier, Florian; Rauschenberg, Jaane; Semmler, Wolfhard; Huber, Peter E.; Bock, Michael

    2010-03-01

    Magnetic resonance imaging guided focus ultrasound surgery (MRgFUS) is a highly precise method to ablate tissue non-invasively. The objective of this ongoing work is to establish an MRgFUS therapy unit consisting of a specially designed FUS applicator as an add-on to a commercial robotic assistance system originally designed for percutaneous needle interventions in whole-body MRI systems. The fully MR compatible robotic assistance system InnoMotion™ (Synthes Inc., West Chester, USA; formerly InnoMedic GmbH, Herxheim, Germany) offers six degrees of freedom. The developed add-on FUS treatment applicator features a fixed focus ultrasound transducer (f = 1.7 MHz; f' = 68 mm, NA = 0.44, elliptical shaped -6-dB-focus: 8.1 mm length; O/ = 1.1 mm) embedded in a water-filled flexible bellow. A Mylar® foil is used as acoustic window encompassed by a dedicated MRI loop coil. For FUS application, the therapy unit is directly connected to the head of the robotic system, and the treatment region is targeted from above. A newly in-house developed software tool allowed for complete remote control of the MRgFUS-robot system and online analysis of MRI thermometry data. The system's ability for therapeutic relevant focal spot scanning was tested in a closed-bore clinical 1.5 T MR scanner (Magnetom Symphony, Siemens AG, Erlangen, Germany) in animal experiments with pigs. The FUS therapy procedure was performed entirely under MRI guidance including initial therapy planning, online MR-thermometry, and final contrast enhanced imaging for lesion detection. In vivo trials proved the MRgFUS-robot system as highly MR compatible. MR-guided focal spot scanning experiments were performed and a well-defined pattern of thermal tissue lesions was created. A total in vivo positioning accuracy of the US focus better than 2 mm was estimated which is comparable to existing MRgFUS systems. The newly developed FUS-robotic system offers an accurate, highly flexible focus positioning. With its access

  15. [Drainage of amoebic liver abscess by single incision laparoscopic surgery. Report of a case].

    Science.gov (United States)

    Telich-Tarriba, José Eduardo; Parrao-Alcántara, Iris Jocelyn; Montes-Hernández, Jesús Manuel; Vega-Pérez, Jesús

    2015-01-01

    Single incision laparoscopic surgery has increased recently due to successful results, achieved in several procedures. The aim of the present work is to present the first case in which single incision laparoscopy is used for the drainage of an amoebic liver abscess. A 44-year-old man presented with intense right upper quadrant pain, generalised jaundice, tachycardia, fever, hepatomegaly and a positive Murphy's sign. Laboratory results revealed an increased plasma bilirubin, elevated alkaline phosphatase and transaminases, leucocytosis, negative viral panel for hepatitis, and positive antibodies against Entamoeba histolytica. On an abdominal computed tomography a 15 × 12.1 cm hypodense lesion was observed in the patient's liver, identified as an amoebic liver abscess. Analgesics and antibiotics were started and subsequently the patient was submitted to laparoscopic drainage of the abscess using a single port approach. Drainage and irrigation of the abscess was performed. Four days later the patient was discharged without complications. Management of amoebic liver abscess is focused on the elimination of the infectious agent and obliteration of the abscess cavity in order to prevent its complications, especially rupture. Laparoscopic surgery has proved to be a safe and effective way to manage this entity. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.

  16. Surgical Residents are Excluded From Robot-assisted Surgery

    DEFF Research Database (Denmark)

    Broholm, Malene; Rosenberg, Jacob

    2015-01-01

    PURPOSE: Implementation of a robotic system may influence surgical training. The aim was to report the charge of the operating surgeon and the bedside assistant at robot-assisted procedures in urology, gynecology, and colorectal surgery. MATERIALS AND METHODS: A review of hospital charts from...... performed. In 10 (1.3%) of these procedures, a resident attended as bedside assistant and never as operating surgeon in the console. CONCLUSIONS: Our results demonstrate a severe problem with surgical education. Robot-assisted surgery is increasingly used; however, robotic surgical training during residency...... surgical procedures during a 1-year period from October 2013 to October 2014. All robot-assisted urologic, gynecologic, and colorectal procedures were identified. Charge of both operating surgeon in the console and bedside assistant were registered. RESULTS: A total of 774 robot-assisted procedures were...

  17. Open versus laparoscopic liver resection for colorectal liver metastases (the Oslo-CoMet Study): study protocol for a randomized controlled trial.

    Science.gov (United States)

    Fretland, Åsmund Avdem; Kazaryan, Airazat M; Bjørnbeth, Bjørn Atle; Flatmark, Kjersti; Andersen, Marit Helen; Tønnessen, Tor Inge; Bjørnelv, Gudrun Maria Waaler; Fagerland, Morten Wang; Kristiansen, Ronny; Øyri, Karl; Edwin, Bjørn

    2015-03-04

    Laparoscopic liver resection is used in specialized centers all over the world. However, laparoscopic liver resection has never been compared with open liver resection in a prospective, randomized trial. The Oslo-CoMet Study is a randomized trial into laparoscopic versus open liver resection for the surgical management of hepatic colorectal metastases. The primary outcome is 30-day perioperative morbidity. Secondary outcomes include 5-year survival (overall, disease-free and recurrence-free), resection margins, recurrence pattern, postoperative pain, health-related quality of life, and evaluation of the inflammatory response. A cost-utility analysis of replacing open surgery with laparoscopic surgery will also be performed. The study includes all resections for colorectal liver metastases, except formal hemihepatectomies, resections where reconstruction of vessels/bile ducts is necessary and resections that need to be combined with ablation. All patients will participate in an enhanced recovery after surgery program. A biobank of liver and tumor tissue will be established and molecular analysis will be performed. After 35 months of recruitment, 200 patients have been included in the trial. Molecular and immunology data are being analyzed. Results for primary and secondary outcome measures will be presented following the conclusion of the study (late 2015). The Oslo-CoMet Study will provide the first level 1 evidence on the benefits of laparoscopic liver resection for colorectal liver metastases. The trial was registered in ClinicalTrals.gov (NCT01516710) on 19 January 2012.

  18. Robotic-assisted surgery in ophthalmology.

    Science.gov (United States)

    de Smet, Marc D; Naus, Gerrit J L; Faridpooya, Koorosh; Mura, Marco

    2018-05-01

    Provide an overview of the current landscape of robotics in ophthalmology, including the pros and cons of system designs, the clinical development path, and the likely future direction of the field. Robots designed for eye surgery should meet certain basic requirements. Three designs are currently being developed: smart surgical tools such as the steady hand, comanipulation devices and telemanipulators using either a fixed or virtual remote center of motion. Successful human intraocular surgery is being performed using the Preceyes surgical system. Another telemanipulation robot, the da Vinci Surgical System, has been used to perform a pterygium repair in humans and was successful in ex-vivo corneal surgery despite its nonophthalmic design. Apart from Preceyes' BV research platform, none of the currently eye-specific systems has reached a commercial stage. Systems are likely to evolve from robotic assistance during specific procedural steps to semiautonomous surgery, as smart sensors are introduced to enhance the basic functionalities of robotic systems. Robotics is still in its infancy in ophthalmology but is rapidly reaching a stage wherein it will be introduced into everyday ophthalmic practice. It will most likely be introduced first for demanding vitreo-retinal procedures, followed by anterior segment applications.

  19. Influence of body habitus on feasibility and outcome of laparoscopic liver resections: a prospective study.

    Science.gov (United States)

    Ratti, Francesca; D'Alessandro, Valentina; Cipriani, Federica; Giannone, Fabio; Catena, Marco; Aldrighetti, Luca

    2016-06-01

    The aim of the present study was to prospectively investigate whether the anthropometric measures of A Body Shape Index (ABSI, taking into account waist circumference adjusted for height and weight) affects feasibility and outcome of laparoscopic liver resections. One hundred patients undergoing laparoscopic liver resection were prospectively included in the study (2014-2015). Preoperative clinical parameters, including body mass index (BMI) and ABSI were evaluated for associations with intraoperative outcome and postoperative results (morbidity, mortality and functional recovery). Twenty-two and 78 patients underwent major and minor hepatectomies, respectively. Conversion rate was 9%, mean blood loss was 210 ± 115 ml. Postoperative morbidity was 15% and mortality was nil. Mean length of stay was 4 days. When considering the entire series, ABSI was not associated with intra and postoperative outcome. After stratification of patients according to difficulty score, Pearson's correlation demonstrated an association between ABSI and intraoperative blood loss (P = 0.03) and time for functional recovery (P = 0.05) in patients undergoing resections with high score of difficulty. Body habitus has an influence on outcome of laparoscopic liver resections with high degree of difficulty, while feasibility and outcome of low difficulty resections seem not to be affected by anthropometric measures. © 2016 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  20. Fast-track program in laparoscopic liver surgery: Theory or fact?

    Science.gov (United States)

    Sánchez-Pérez, Belinda; Aranda-Narváez, José Manuel; Suárez-Muñoz, Miguel Angel; Eladel-Delfresno, Moises; Fernández-Aguilar, José Luis; Pérez-Daga, Jose Antonio; Pulido-Roa, Ysabel; Santoyo-Santoyo, Julio

    2012-11-27

    To analyze our results after the introduction of a fast-track (FT) program after laparoscopic liver surgery in our Hepatobiliarypancreatic Unit. All patients (43) undergoing laparoscopic liver surgery between March 2004 and March 2010 were included and divided into two consecutive groups: Control group (CG) from March 2004 until December 2006 with traditional perioperative cares (17 patients) and fast-track group (FTG) from January 2007 until March 2010 with FT program cares (26 patients). Primary endpoint was the influence of the program on the postoperative stay, the amount of re-admissions, morbidity and mortality. Secondarily we considered duration of surgery, use of drains, conversion to open surgery, intensive cares needs and transfusion. Both groups were homogeneous in age and sex. No differences in technique, time of surgery or conversion to open surgery were found, but more malignant diseases were operated in the FTG, and then transfusions were higher in FTG. Readmissions and morbidity were similar in both groups, without mortality. Postoperative stay was similar, with a median of 3 for CG vs 2.5 for FTG. However, the 80.8% of patients from FTG left the hospital within the first 3 d after surgery (58.8% for CG). The introduction of a FT program after laparoscopic liver surgery improves the recovery of patients without increasing complications or re-admissions, which leads to a reduction of the stay and costs.

  1. Laparoscopic splenectomy for hypersplenism secondary to liver cirrhosis and portal hypertension

    Science.gov (United States)

    Zhan, Xiao-Li; Ji, Yun; Wang, Yue-Dong

    2014-01-01

    Since the first laparoscopic splenectomy (LS) was reported in 1991, LS has become the gold standard for the removal of normal to moderately enlarged spleens in benign conditions. Compared with open splenectomy, fewer postsurgical complications and better postoperative recovery have been observed, but LS is contraindicated for hypersplenism secondary to liver cirrhosis in many institutions owing to technical difficulties associated with splenomegaly, well-developed collateral circulation, and increased risk of bleeding. With the improvements of laparoscopic technique, the concept is changing. This article aims to give an overview of the latest development in laparoscopic splenectomy for hypersplenism secondary to liver cirrhosis and portal hypertension. Despite a lack of randomized controlled trial, the publications obtained have shown that with meticulous surgical techniques and advanced instruments, LS is a technically feasible, safe, and effective procedure for hypersplenism secondary to cirrhosis and portal hypertension and contributes to decreased blood loss, shorter hospital stay, and less impairment of liver function. It is recommended that the dilated short gastric vessels and other enlarged collateral circulation surrounding the spleen be divided with the LigaSure vessel sealing equipment, and the splenic artery and vein be transected en bloc with the application of the endovascular stapler. To support the clinical evidence, further randomized controlled trials about this topic are necessary. PMID:24914339

  2. Laparoscopic microwave thermosphere ablation of malignant liver tumors: an initial clinical evaluation.

    Science.gov (United States)

    Berber, Eren

    2016-02-01

    Microwave ablation (MWA) has been recently recognized as a technology to overcome the limitations of radiofrequency ablation. The aim of the current study was to evaluate the safety and efficacy of a new 2.45-GHz thermosphere MWA system in the treatment of malignant liver tumors. This was a prospective IRB-approved study of 18 patients with malignant liver tumors treated with MWA within a 3-month time period. Tumor sizes and response to MWA were obtained from triphasic liver CT scans done before and after MWA. The ablation zones were assessed for complete tumor response and spherical geometry. There were a total of 18 patients with an average of three tumors measuring 1.4 cm (range 0.2-4). Ablations were performed laparoscopically in all, but three patients who underwent combined liver resection. A single ablation was created in 72% and overlapping ablations in 28% of lesions. Total ablation time per patient was 15.6 ± 1.9 min. There was no morbidity or mortality. At 2-week CT scans, there was 100% tumor destruction, with no residual lesions. Roundness indices A, B and transverse were 1.1, 0.9 and 0.9, respectively, confirming the spherical nature of ablation zones. To the best of our knowledge, this is the first report of a new thermosphere MWA technology in the laparoscopic treatment of malignant liver tumors. The results demonstrate the safety of the technology, with satisfactory spherical ablation zones seen on post-procedural CT scans.

  3. Prospective analysis of completely stentless robot-assisted pyeloplasty in children.

    Science.gov (United States)

    Casale, Pasquale; Lambert, Sarah

    2010-01-01

    Robot-assisted pyeloplasty (RAP) is emerging as an effective tool for treatment of ureteropelvic junction obstruction (UPJO) in the pediatric population. Typically stents are utilized for RAP and removed four weeks after the procedure. We present our prospective experience with stentless RAP. Twenty children between the ages of 12 and 113 months (mean age 56 months) underwent transperitoneal RAP for UPJO utilizing the DaVinci surgical system. Outcome measures included operative time, length of hospital stay, and resolution of obstruction by ultrasonography, magnetic resonance urography (MRU), and/or diuretic radionuclide imaging (DRI). All patients successfully underwent robot-assisted laparoscopic pyeloplasty without conversion to pure laparoscopy or open procedure. Mean operative time was 124.7 min with a mean console time of 82.3 min. The mean hospital stay was 18 h. Of the 20 patients, 13/20 (65%) had resolution or improvement in the degree of hydronephrosis. The other patients had no evidence of obstruction based upon follow-up MRU or DRI. Stentless RAP is a safe and effective option for surgical treatment of UPJO. A larger prospective long-term cohort is needed to confirm the safety and efficacy of the stentless approach.

  4. Bloodless laparoscopic liver resection using radiofrequency thermal energy in the porcine model.

    Science.gov (United States)

    Tsalis, Konstantinos; Blouhos, Konstantinos; Vasiliadis, Konstantinos; Kalfadis, Stavros; Tsachalis, Theodoros; Savvas, Ioannis; Betsis, Dimitrios

    2007-02-01

    The aim of this study was to assess the feasibility and safety of laparoscopic hepatectomy using radiofrequency (RF) thermal energy in a porcine model. Fifteen female domestic pigs weighing 29.3 kg (range 25 to 35 kg) were used. Five transversal abdominal incisions (3 of 1 cm and 2 of 0.5 cm) were made for the introduction of the video camera and the other laparoscopic instruments. With the porta hepatis not clamped, the liver was inspected and the preferred lobe each time was divided using RF (cool-tip electrode 3 cm) with minimum bleeding. Serum liver enzymes and blood counts were drawn pre and postoperatively. All animals were killed after 1 week. The mean time of the procedures was 119 minutes (range 100 to 155 min). There were no intraoperative complications. Mean blood loss was 27 mL (range 5 to 60 mL), and the mass of the resected specimen was 132.5 g (range 65 to 305 g). There were no postoperative complications or deaths. Bloodless laparoscopic hepatectomy was technically feasible and safe in the porcine model using cool-tip electrode and 500-kHz RF Generator.

  5. General surgery residents' perception of robot-assisted procedures during surgical training.

    Science.gov (United States)

    Farivar, Behzad S; Flannagan, Molly; Leitman, I Michael

    2015-01-01

    With the continued expansion of robotically assisted procedures, general surgery residents continue to receive more exposure to this new technology as part of their training. There are currently no guidelines or standardized training requirements for robot-assisted procedures during general surgical residency. The aim of this study was to assess the effect of this new technology on general surgery training from the residents' perspective. An anonymous, national, web-based survey was conducted on residents enrolled in general surgery training in 2013. The survey was sent to 240 Accreditation Council for Graduate Medical Education-approved general surgery training programs. Overall, 64% of the responding residents were men and had an average age of 29 years. Half of the responses were from postgraduate year 1 (PGY1) and PGY2 residents, and the remainder was from the PGY3 level and above. Overall, 50% of the responses were from university training programs, 32% from university-affiliated programs, and 18% from community-based programs. More than 96% of residents noted the availability of the surgical robot system at their training institution. Overall, 63% of residents indicated that they had participated in robotic surgical cases. Most responded that they had assisted in 10 or fewer robotic cases with the most frequent activities being assisting with robotic trocar placement and docking and undocking the robot. Only 18% reported experience with operating the robotic console. More senior residents (PGY3 and above) were involved in robotic cases compared with junior residents (78% vs 48%, p robotic case. Approximately 64% of residents reported that formal training in robotic surgery was important in residency training and 46% of residents indicated that robotic-assisted cases interfered with resident learning. Only 11% felt that robotic-assisted cases would replace conventional laparoscopic surgery in the future. This study illustrates that although the most residents

  6. Robot-assisted automatic ultrasound calibration.

    Science.gov (United States)

    Aalamifar, Fereshteh; Cheng, Alexis; Kim, Younsu; Hu, Xiao; Zhang, Haichong K; Guo, Xiaoyu; Boctor, Emad M

    2016-10-01

    Ultrasound (US) calibration is the process of determining the unknown transformation from a coordinate frame such as the robot's tooltip to the US image frame and is a necessary task for any robotic or tracked US system. US calibration requires submillimeter-range accuracy for most applications, but it is a time-consuming and repetitive task. We provide a new framework for automatic US calibration with robot assistance and without the need for temporal calibration. US calibration based on active echo (AE) phantom was previously proposed, and its superiority over conventional cross-wire phantom-based calibration was shown. In this work, we use AE to guide the robotic arm motion through the process of data collection; we combine the capability of the AE point to localize itself in the frame of the US image with the automatic motion of the robotic arm to provide a framework for calibrating the arm to the US image automatically. We demonstrated the efficacy of the automated method compared to the manual method through experiments. To highlight the necessity of frequent ultrasound calibration, it is demonstrated that the calibration precision changed from 1.67 to 3.20 mm if the data collection is not repeated after a dismounting/mounting of the probe holder. In a large data set experiment, similar reconstruction precision of automatic and manual data collection was observed, while the time was reduced by 58 %. In addition, we compared ten automatic calibrations with ten manual ones, each performed in 15 min, and showed that all the automatic ones could converge in the case of setting the initial matrix as identity, while this was not achieved by manual data sets. Given the same initial matrix, the repeatability of the automatic was [0.46, 0.34, 0.80, 0.47] versus [0.42, 0.51, 0.98, 1.15] mm in the manual case for the US image four corners. The submillimeter accuracy requirement of US calibration makes frequent data collections unavoidable. We proposed an automated

  7. Real-Time Augmented Reality for Robotic-Assisted Surgery

    DEFF Research Database (Denmark)

    Jørgensen, Martin Kibsgaard; Kraus, Martin

    2015-01-01

    Training in robotic-assisted minimally invasive surgery is crucial, but the training with actual surgery robots is relatively expensive. Therefore, improving the efficiency of this training is of great interest in robotic surgical education. One of the current limitations of this training is the ......-dimensional computer graphics in real time. Our system makes it possible to easily deploy new user interfaces for robotic-assisted surgery training. The system has been positively evaluated by two experienced instructors in robot-assisted surgery....... is the limited visual communication between the instructor and the trainee. As the trainee's view is limited to that of the surgery robot's camera, even a simple task such as pointing is difficult. We present a compact system to overlay the video streams of the da Vinci surgery systems with interactive three...

  8. Laparoscopic versus open liver segmentectomy: prospective, case-matched, intention-to-treat analysis of clinical outcomes and cost effectiveness.

    Science.gov (United States)

    Polignano, Francesco M; Quyn, Aaron J; de Figueiredo, Rodrigo S M; Henderson, Nikola A; Kulli, Christoph; Tait, Iain S

    2008-12-01

    Reduction in hospital stay, blood loss, postoperative pain and complications are common findings after laparoscopic liver resection, suggesting that the laparoscopic approach may be a suitable alternative to open surgery. Some concerns have been raised regarding cost effectiveness of this procedure and potential implications of its large-scale application. Our aim has been to determine cost effectiveness of laparoscopic liver surgery by a case-matched, case-control, intention-to-treat analysis of its costs and short-term clinical outcomes compared with open surgery. Laparoscopic liver segmentectomies and bisegmentectomies performed at Ninewells Hospital and Medical School between 2005 and 2007 were considered. Resections involving more than two Couinaud segments, or involving any synchronous procedure, were excluded. An operation-magnitude-matched control group was identified amongst open liver resections performed between 2004 and 2007. Hospital costs were obtained from the Scottish Health Service Costs Book (ISD Scotland) and average national costs were calculated. Cost of theatre time, disposable surgical devices, hospital stay, and high-dependency unit (HDU) and intensive care unit (ICU) usage were the main endpoints for comparison. Secondary endpoints were morbidity and mortality. Statistical analysis was performed with Student's t-test, chi(2) and Fisher exact test as most appropriate. Twenty-five laparoscopic liver resections were considered, including atypical resection, segmentectomy and bisegmentectomy, and they were compared to 25 matching open resections. The two groups were homogeneous by age, sex, coexistent morbidity, magnitude of resection, prevalence of liver cirrhosis and indications. Operative time (p < 0.03), blood loss (p < 0.0001), Pringle manoeuvre (p < 0.03), hospital stay (p < 0.003) and postoperative complications (p < 0.002) were significantly reduced in the laparoscopic group. Overall hospital cost was significantly lower in the

  9. Da Vinci Xi Robot-Assisted Penetrating Keratoplasty.

    Science.gov (United States)

    Chammas, Jimmy; Sauer, Arnaud; Pizzuto, Joëlle; Pouthier, Fabienne; Gaucher, David; Marescaux, Jacques; Mutter, Didier; Bourcier, Tristan

    2017-06-01

    This study aims (1) to investigate the feasibility of robot-assisted penetrating keratoplasty (PK) using the new Da Vinci Xi Surgical System and (2) to report what we believe to be the first use of this system in experimental eye surgery. Robot-assisted PK procedures were performed on human corneal transplants using the Da Vinci Xi Surgical System. After an 8-mm corneal trephination, four interrupted sutures and one 10.0 monofilament running suture were made. For each procedure, duration and successful completion of the surgery as well as any unexpected events were assessed. The depth of the corneal sutures was checked postoperatively using spectral-domain optical coherence tomography (SD-OCT). Robot-assisted PK was successfully performed on 12 corneas. The Da Vinci Xi Surgical System provided the necessary dexterity to perform the different steps of surgery. The mean duration of the procedures was 43.4 ± 8.9 minutes (range: 28.5-61.1 minutes). There were no unexpected intraoperative events. SD-OCT confirmed that the sutures were placed at the appropriate depth. We confirm the feasibility of robot-assisted PK with the new Da Vinci Surgical System and report the first use of the Xi model in experimental eye surgery. Operative time of robot-assisted PK surgery is now close to that of conventional manual surgery due to both improvement of the optical system and the presence of microsurgical instruments. Experimentations will allow the advantages of robot-assisted microsurgery to be identified while underlining the improvements and innovations necessary for clinical use.

  10. Robotic Assisted Radical Cystoprostatectomy and Intracorporeal Ileal Conduit Urinary Diversion for a Kidney Transplant Recipient

    Directory of Open Access Journals (Sweden)

    Peter A. Caputo

    Full Text Available ABSTRACT Introduction and Objectives: Robotic assisted radical cystectomy (RARC is an alternative to open radical cystectomy. As experience is gained with the RARC approach the technique is being applied to more complex surgical cases. We describe here our technique for RARC with intracorporeal ileal conduit urinary diversion for a renal transplant recipient. Materials and Methods: The patient is a 60-year old man with high-grade muscle invasive bladder cancer. He has a history of renal failure due to polycystic kidney disease and received a deceased donor renal transplant in 2008. His hospital course at time of transplant was complicated by low-level BK virus viremia. Interestingly his trans-urethral bladder tumor resection specimen at time of bladder cancer diagnosis stained positive for SV40. His native kidneys were anuric so bilateral laparoscopic nephrectomy was performed in a staged fashion 2 weeks prior to RARC. Our surgical technique utilizes 6 trocars, of note a 12-mm assistant trocar is placed 1 cm superior to the pubic symphysis, and this trocar is solely used to pass a laparoscopic stapler to facilitate the excision of the ileal segment and the stapled enteric anastomosis. Surgical steps include: identification of native ureters bilaterally (removed en bloc with the bladder specimen; identification of the transplanted ureter at the right bladder dome; posterior bladder and prostate dissection along Denonvilliers’ fascia; development of the space of Retzius; ligation and transection of the bladder and prostate vascular bundles; apical prostate dissection and transection of urethra; left pelvic lymphadenectomy; ilium resection for creation of the ileal conduit; stapled enteric anastomosis; ureteroileal anastomosis; maturation of the ileal conduit stoma. Results: The surgery had no intraoperative complications. Operative time was 443 minutes (7.4 hours. Estimated blood loss was 250 cc. Length of hospital stay was 5 days. The patient

  11. A comparison of laparoscopic radiofrequency ablation versus systemic therapy alone in the treatment of breast cancer metastasis to the liver

    Science.gov (United States)

    Taşçi, Yunus; Aksoy, Erol; Taşkın, Halit Eren; Aliyev, Shamil; Moore, Halle; Ağcaoğlu, Orhan; Birsen, Onur; Siperstein, Allan; Berber, Eren

    2013-01-01

    Objectives There is controversy about the roles of locoregional therapies in patients with liver metastases from breast cancer (LMBC). The aim of this study was to analyse survival after laparoscopic radiofrequency ablation (RFA) of LMBC and to compare this with survival in patients receiving systemic therapy (ST) alone. Methods During 1996–2011, 24 patients who had failed to respond or had shown an incomplete response to ST underwent laparoscopic RFA for LMBC. Outcomes in these patients were compared with those in 32 patients with LMBC matched by tumour size and number, but treated with ST alone. Clinical parameters and overall survival were compared using t-tests, chi-squared tests and Kaplan–Meier analysis. Results The groups were similar in hormone receptor status and chemotherapy exposure. In the laparoscopic RFA and ST groups, respectively, the mean ± standard deviation size of the dominant liver tumour and the number of tumours per patient were 3.7 ± 0.4 cm and 2.4 ± 0.4 cm, and 2.6 ± 0.4 tumours and 3.3 ± 0.4 tumours, respectively. These differences were not significant. At a median follow-up of 20 months in the laparoscopic RFA group, 42% of patients were found to have developed local liver recurrence, 63% had developed new liver disease and 38% had developed extrahepatic disease. Overall survival after the diagnosis of liver metastasis was 47 months in the laparoscopic RFA group and 9 months in the ST-only group (P = 0.0001). Five-year survival after the diagnosis of liver metastasis was 29% in the RFA group and 0% in the ST-only group. Conclusions This is the first study to compare outcomes in RFA and ST, respectively, in LMBC. The results show that survival after laparoscopic RFA plus ST is better than that after ST alone. PMID:24028270

  12. Robot-assisted bronchoplasty using continuous barbed sutures.

    Science.gov (United States)

    Sarsam, Omar Matthieu; Dunning, Joel; Pochulu, Bruno; Baste, Jean-Marc

    2018-01-01

    We describe in this article our bronchoplastic robot-assisted techniques. This consists of using continuous barbed sutures. Our aim is to show the feasibility and the interest of using robotics and this kind of suture material for complex bronchial procedures. We report four cases in France and the UK, two wedge bronchoplasties and two sleeve bronchoplasties for central pulmonary tumors.

  13. Monitoring of Robot Assisted Polishing through parameters of acoustic emission

    DEFF Research Database (Denmark)

    Lazarev, Ruslan; Top, Søren; Bilberg, Arne

    The polishing process is essential for the surface generation of machine tooling components in advanced manufacturing. While robot assisted polishing is faster and more consistent than manual polishing, it can still consume a significant part of ma- chining time and operator presence time...

  14. Ultrasound-based tumor movement compensation during navigated laparoscopic liver interventions.

    Science.gov (United States)

    Shahin, Osama; Beširević, Armin; Kleemann, Markus; Schlaefer, Alexander

    2014-05-01

    Image-guided navigation aims to provide better orientation and accuracy in laparoscopic interventions. However, the ability of the navigation system to reflect anatomical changes and maintain high accuracy during the procedure is crucial. This is particularly challenging in soft organs such as the liver, where surgical manipulation causes significant tumor movements. We propose a fast approach to obtain an accurate estimation of the tumor position throughout the procedure. Initially, a three-dimensional (3D) ultrasound image is reconstructed and the tumor is segmented. During surgery, the position of the tumor is updated based on newly acquired tracked ultrasound images. The initial segmentation of the tumor is used to automatically detect the tumor and update its position in the navigation system. Two experiments were conducted. First, a controlled phantom motion using a robot was performed to validate the tracking accuracy. Second, a needle navigation scenario based on pseudotumors injected into ex vivo porcine liver was studied. In the robot-based evaluation, the approach estimated the target location with an accuracy of 0.4 ± 0.3 mm. The mean navigation error in the needle experiment was 1.2 ± 0.6 mm, and the algorithm compensated for tumor shifts up to 38 mm in an average time of 1 s. We demonstrated a navigation approach based on tracked laparoscopic ultrasound (LUS), and focused on the neighborhood of the tumor. Our experimental results indicate that this approach can be used to quickly and accurately compensate for tumor movements caused by surgical manipulation during laparoscopic interventions. The proposed approach has the advantage of being based on the routinely used LUS; however, it upgrades its functionality to estimate the tumor position in 3D. Hence, the approach is repeatable throughout surgery, and enables high navigation accuracy to be maintained.

  15. Resident education in robotic-assisted vertical sleeve gastrectomy: outcomes and cost-analysis of 411 consecutive cases.

    Science.gov (United States)

    Ecker, Brett L; Maduka, Richard; Ramdon, Andre; Dempsey, Daniel T; Dumon, Kristoffel R; Williams, Noel N

    2016-02-01

    Robotic technology is increasingly prevalent in bariatric surgery, yet there are national deficiencies in exposure of surgical residents to robotic techniques. The purpose of this study is to accurately characterize the perioperative outcomes of a resident teaching model using the robotic-assisted sleeve gastrectomy. University Hospital. We identified 411 consecutive patients who underwent robotic sleeve gastrectomy at our institution from a prospectively maintained administrative database. Perioperative morbidity, operative time, and supply cost of the procedure were analyzed. Mean operative time was 96.4±24.9 minutes; mean robot usage time was 63.9 minutes (range 30.0-122.0 min). Ninety-day morbidities included reoperation (0.72%), major bleeding complications (0.48%), staple line leak (0.24%), stricture (0.97%), need for blood transfusion (3.86%), surgical site infection (1.69%), deep vein thrombosis (0.48%), and pulmonary embolism (0.48%). Mortality was nil. The resident cohort achieved operative time plateaus after five consecutive cases. Subset analysis for fiscal year 2014 demonstrated significantly increased supply cost for robotic sleeve gastrectomy compared with its laparoscopic equivalent. Robotic-assisted sleeve gastrectomy can be instituted as a model for resident robotic education with rates of morbidity and operative times equivalent to historical laparoscopic controls. The robot's enhanced ergonomics and its opportunity for resident education must be weighed against its increased supply cost. Copyright © 2016 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.

  16. Disk suspension method: a novel and safe technique for the retraction of the liver during laparoscopic surgery (with video).

    Science.gov (United States)

    Shibao, Kazunori; Higure, Aiichiro; Yamaguchi, Koji

    2011-08-01

    A good operative field is important for safe operations, but it is sometimes difficult to obtain a satisfactory operative field in laparoscopic upper abdominal surgery. We developed a novel and safe technique for the retraction of the liver and falciform ligament during laparoscopic surgery, and evaluated its technical feasibility and safety. Forty-three patients with gastric cancer were divided into two groups: disk suspension group (DS group; snake retractor and elastic band fixation with a silicon disk), and fixed retractor group (FR group; snake retractor and nonelastic band fixation without a silicon disk). To evaluate liver damage during retraction, we measured the aspartate aminotransferase (AST) and alanine aminotransferase (ALT) levels preoperatively and on postoperative day (POD) 1. In the DS group, all liver lobes were adequately retracted and the hepatoduodenal and gastrohepatic ligaments were fully exposed. This procedure took less than 3 min. On the other hand, 5 of 18 patients of the FR group had insufficient surgical fields for laparoscopic gastrectomy because of soft and/or large livers. Although the preoperative AST and ALT levels were not different between the two groups, the DS group did not display increases in both AST and ALT levels, whereas the FR group showed increases in both on POD 1 (AST: 50.2 ± 8.4 IU/l vs. 124.2 ± 37.7 IU/l, P = 0.07; and ALT: 35.6 ± 6.4 IU/l vs. 106.1 ± 36.2 IU/l, P = 0.07). No complications related to the liver retraction were observed in the DS group. However, liver congestion was evident in six patients and minor liver injury in two patients of the FR group during the esophagojejunostomy. The DS method is a simple and safe and provides a better surgical field during laparoscopic surgery of the upper abdomen without damaging the liver.

  17. Inflammatory Response After Laparoscopic Versus Open Resection of Colorectal Liver Metastases Data From the Oslo-CoMet Trial: Erratum.

    Science.gov (United States)

    2016-03-01

    In the article ''Inflammatory Response After Laparoscopic Versus Open Resection of Colorectal Liver Metastases Data From the Oslo-CoMet Trial'', which appeared in Volume 94, Issue 42 of Medicine, the University of Oslo was not credited as the affiliation for several authors. The article has since been corrected online.

  18. [Robot-assisted Pylorus-Preserving Partial Pancreaticoduodenectomy (Kausch-Whipple Procedure)].

    Science.gov (United States)

    Aselmann, H; Egberts, J-H; Hinz, S; Jünemann, K-P; Becker, T

    2016-04-01

    The surgical treatment of pancreatic head tumours is one of the most complex procedures in general surgery. In contrast to colorectal surgery, minimally-invasive techniques are not very commonly applied in pancreatic surgery. Both the delicate dissection along peri- and retropancreatic vessels and the extrahepatic bile ducts and subsequent reconstruction are very demanding with rigid standard laparoscopic instruments. The 4-arm robotic surgery system with angled instruments, unidirectional movement of instruments with adjustable transmission, tremor elimination and a stable, surgeon-controlled 3D-HD view is a promising platform to overcome the limitations of standard laparoscopic surgery regarding precise dissection and reconstruction in pancreatic surgery. Pancreatic head resection for mixed-type IPMN of the pancreatic head. Robot-assisted, minimally-invasive pylorus-preserving pancreaticoduodenectomy (Kausch-Whipple procedure). The robotic approach is particularly suited for complex procedures such as pylorus-preserving pancreatic head resections. The fully robotic Kausch-Whipple procedure is technically feasible and safe. The advantages of the robotic system are apparent in the delicate dissection near vascular structures, in lymph node dissection, the precise dissection of the uncinate process and, especially, bile duct and pancreatic anastomosis. Georg Thieme Verlag KG Stuttgart · New York.

  19. The first clinical application of planning software for laparoscopic microwave thermosphere ablation of malignant liver tumours.

    Science.gov (United States)

    Berber, Eren

    2015-07-01

    Liver tumour ablation is an operator-dependent procedure. The determination of the optimum needle trajectory and correct ablation parameters could be challenging. The aim of this study was to report the utility of a new, procedure planning software for microwave ablation (MWA) of liver tumours. This was a feasibility study in a pilot group of five patients with nine metastatic liver tumours who underwent laparoscopic MWA. Pre-operatively, parameters predicting the desired ablation zones were calculated for each tumour. Intra-operatively, this planning strategy was followed for both antenna placement and energy application. Post-operative 2-week computed tomography (CT) scans were performed to evaluate complete tumour destruction. The patients had an average of two tumours (range 1-4), measuring 1.9 ± 0.4 cm (range 0.9-4.4 cm). The ablation time was 7.1 ± 1.3 min (range 2.5-10 min) at 100W. There were no complications or mortality. The patients were discharged home on post-operative day (POD) 1. At 2-week CT scans, there were no residual tumours, with a complete ablation demonstrated in all lesions. This study describes and validates pre-treatment planning software for MWA of liver tumours. This software was found useful to determine precisely the ablation parameters and needle placement to create a predicted zone of ablation. © 2015 International Hepato-Pancreato-Biliary Association.

  20. Outcomes of complex robot-assisted extravesical ureteral reimplantation in the pediatric population.

    Science.gov (United States)

    Arlen, Angela M; Broderick, Kristin M; Travers, Curtis; Smith, Edwin A; Elmore, James M; Kirsch, Andrew J

    2016-06-01

    While open ureteral reimplantation remains the gold standard for surgical treatment of vesicoureteral reflux (VUR), minimally invasive approaches offer potential benefits. This study evaluated the outcomes of children undergoing complex robot-assisted laparoscopic ureteral reimplantation (RALUR) for failed previous anti-reflux surgery, complex anatomy, or ureterovesical junction obstruction (UVJO), and compared them with patients undergoing open extravesical repair. Children undergoing complex RALUR or open extravesical ureteral reimplantation (OUR) were identified. Reimplantation was classified as complex if ureters: 1) had previous anti-reflux surgery, 2) required tapering and/or dismembering, or 3) had associated duplication or diverticulum. Seventeen children underwent complex RALUR during a 24-month period, compared with 41 OUR. The mean follow-up was 16.6 ± 6.5 months. The RALUR children were significantly older (9.3 ± 3.7 years) than the OUR patients (3.1 ± 2.7 years; P urinary tract infection compared with a single child (5.9%) undergoing RALUR (P = 1.00). There was no significant difference in complication rate between the two groups (12.2% OUR versus 11.8% RALUR; P = 1.00). A postoperative cystogram was performed in the majority of RALUR patients, with no persistent VUR detected, and one child (6.7%) was diagnosed with contralateral reflux. Reported VUR resolution rates following robot-assisted ureteral reimplantation are varied. In the present series, children undergoing RALUR following failed previous anti-reflux surgery, with complex anatomy, or UVJO experienced a shorter length of stay but had similar analgesic requirements to those undergoing open repair. Radiographic, clinical success rates and complication risk were comparable. This study had several limitations, aside from lack of randomization. Analgesic use was limited to an inpatient setting, and pain scores were not assessed. Not all children underwent a postoperative VCUG, so

  1. Inflammatory Response After Laparoscopic Versus Open Resection of Colorectal Liver Metastases: Data From the Oslo-CoMet Trial.

    Science.gov (United States)

    Fretland, Asmund Avdem; Sokolov, Andrey; Postriganova, Nadya; Kazaryan, Airazat M; Pischke, Soren E; Nilsson, Per H; Rognes, Ingrid Nygren; Bjornbeth, Bjorn Atle; Fagerland, Morten Wang; Mollnes, Tom Eirik; Edwin, Bjorn

    2015-10-01

    Laparoscopic and open liver resection have not been compared in randomized trials. The aim of the current study was to compare the inflammatory response after laparoscopic and open resection of colorectal liver metastases (CLM) in a randomized controlled trial.This was a predefined exploratory substudy within the Oslo CoMet-study. Forty-five patients with CLM were randomized to laparoscopic (n = 23) or open (n = 22) resection. Ethylenediaminetetraacetic acid-plasma samples were collected preoperatively and at defined time points during and after surgery and snap frozen at -80 C. A total of 25 markers were examined using luminex and enzyme-linked immunosorbent assay techniques: high-mobility box group 1(HMGB-1), cell-free DNA (cfDNA), cytokines, and terminal C5b-9 complement complex complement activation.Eight inflammatory markers increased significantly from baseline: HMGB-1, cfDNA, interleukin (IL)-6, C-reactive protein, macrophage inflammatory protein -1β, monocyte chemotactic protein -1, IL-10, and terminal C5b-9 complement complex. Peak levels were reached at the end of or shortly after surgery. Five markers, HMGB-1, cfDNA, IL-6, C-reactive protein, and macrophage inflammatory protein -1β, showed significantly higher levels in the open surgery group compared with the laparoscopic surgery group.Laparoscopic resection of CLM reduced the inflammatory response compared with open resection. The lower level of HMGB-1 is interesting because of the known association with oncogenesis.

  2. Robot-Assisted Antegrade In-Situ Fenestrated Stent Grafting

    International Nuclear Information System (INIS)

    Riga, Celia V.; Bicknell, Colin D.; Wallace, Daniel; Hamady, Mohamad; Cheshire, Nicholas

    2009-01-01

    To determine the technical feasibility of a novel approach of in-situ fenestration of aortic stent grafts by using a remotely controlled robotic steerable catheter system in the porcine model. A 65-kg pig underwent robot-assisted bilateral antegrade in-situ renal fenestration of an abdominal aortic stent graft with subsequent successful deployment of a bare metal stent into the right renal artery. A 16-mm iliac extension covered stent served as the porcine aortic endograft. Under fluoroscopic guidance, the graft was punctured with a 20-G customized diathermy needle that was introduced and kept in place by the robotic arm. The needle was exchanged for a 4 x 20 mm cutting balloon before successful deployment of the renal stent. Robot-assisted antegrade in-situ fenestration is technically feasible in a large mammalian model. The robotic system enables precise manipulation, stable positioning, and minimum instrumentation of the aorta and its branches while minimizing radiation exposure.

  3. Advances in Robotic-Assisted Radical Prostatectomy over Time

    Directory of Open Access Journals (Sweden)

    Emma F. P. Jacobs

    2013-01-01

    Full Text Available Since the introduction of robot-assisted radical prostatectomy (RALP, robotics has become increasingly more commonplace in the armamentarium of the urologic surgeon. Robotic utilization has exploded across surgical disciplines well beyond the fields of urology and prostate surgery. The literature detailing technical steps, comparison of large surgical series, and even robotically focused randomized control trials are available for review. RALP, the first robot-assisted surgical procedure to achieve widespread use, has recently become the primary approach for the surgical management of localized prostate cancer. As a result, surgeons are constantly trying to refine and improve upon current technical aspects of the operation. Recent areas of published modifications include bladder neck anastomosis and reconstruction, bladder drainage, nerve sparing approaches and techniques, and perioperative and postoperative management including penile rehabilitation. In this review, we summarize recent advances in perioperative management and surgical technique for RALP.

  4. [Initial experience in robot-assisted colorectal surgery in Mexico].

    Science.gov (United States)

    Villanueva-Sáenz, Eduardo; Ramírez-Ramírez, Moisés Marino; Zubieta-O'Farrill, Gregorio; García-Hernández, Luis

    Colorectal surgery has advanced notably since the introduction of the mechanical suture and the minimally invasive approach. Robotic surgery began in order to satisfy the needs of the patient-doctor relationship, and migrated to the area of colorectal surgery. An initial report is presented on the experience of managing colorectal disease using robot-assisted surgery, as well as an analysis of the current role of this platform. A retrospective study was conducted in order to review five patients with colorectal disease operated using a robot-assisted technique over one year in the initial phase of the learning curve. Gender, age, diagnosis and surgical indication, surgery performed, surgical time, conversion, bleeding, post-operative complications, and hospital stay, were analysed and described. A literature review was performed on the role of robotic assisted surgery in colorectal disease and cancer. The study included 5 patients, 3 men and 2 women, with a mean age of 62.2 years. Two of them were low anterior resections with colorectal primary anastomoses, one of them extended with a loop protection ileostomy, a Frykman-Goldberg procedure, and two left hemicolectomies with primary anastomoses. The mean operating time was 6hours and robot-assisted 4hours 20minutes. There were no conversions and the mean hospital stay was 5 days. This technology is currently being used worldwide in different surgical centres because of its advantages that have been clinically demonstrated by various studies. We report the first colorectal surgical cases in Mexico, with promising results. There is enough evidence to support and recommend the use of this technology as a viable and safe option. Copyright © 2016 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  5. Perioperative outcomes of video- and robot-assisted segmentectomies.

    Science.gov (United States)

    Rinieri, Philippe; Peillon, Christophe; Salaün, Mathieu; Mahieu, Julien; Bubenheim, Michael; Baste, Jean-Marc

    2016-02-01

    Video-assisted thoracic surgery appears to be technically difficult for segmentectomy. Conversely, robotic surgery could facilitate the performance of segmentectomy. The aim of this study was to compare the early results of video- and robot-assisted segmentectomies. Data were collected prospectively on videothoracoscopy from 2010 and on robotic procedures from 2013. Fifty-one patients who were candidates for minimally invasive segmentectomy were included in the study. Perioperative outcomes of video-assisted and robotic segmentectomies were compared. The minimally invasive segmentectomies included 32 video- and 16 robot-assisted procedures; 3 segmentectomies (2 video-assisted and 1 robot-assisted) were converted to lobectomies. Four conversions to thoracotomy were necessary for anatomical reason or arterial injury, with no uncontrolled bleeding in the robotic arm. There were 7 benign or infectious lesions, 9 pre-invasive lesions, 25 lung cancers, and 10 metastatic diseases. Patient characteristics, type of segment, conversion to thoracotomy, conversion to lobectomy, operative time, postoperative complications, chest tube duration, postoperative stay, and histology were similar in the video and robot groups. Estimated blood loss was significantly higher in the video group (100 vs. 50 mL, p = 0.028). The morbidity rate of minimally invasive segmentectomy was low. The short-term results of video-assisted and robot-assisted segmentectomies were similar, and more data are required to show any advantages between the two techniques. Long-term oncologic outcomes are necessary to evaluate these new surgical practices. © The Author(s) 2016.

  6. Laparoscopic microwave thermosphere ablation of malignant liver tumors: An analysis of 53 cases.

    Science.gov (United States)

    Zaidi, Nisar; Okoh, Alexis; Yigitbas, Hakan; Yazici, Pinar; Ali, Noaman; Berber, Eren

    2016-02-01

    Microwave thermosphere ablation (MTA) is a new technology that is designed to create spherical zones of ablation using a single antenna. The aim of this study is to assess the results of MTA in a large series of patients. This was a prospective study assessing the use of MTA in patients with malignant liver tumors. The procedures were done mostly laparoscopically and ablation zones created were assessed for completeness of tumor response, spherical geometry and recurrence on tri-phasic CT scans done on follow-up. There were a total of 53 patients with an average of 3 tumors measuring 1.5 cm. Ablations were performed laparoscopically in all but eight patients. Morbidity was 11.3% (n = 6), and mortality zero. On postoperative scans, there was 99.3% tumor destruction. Roundness indices A, B, and transverse were 1.1, 1.0, and 0.9, respectively. At a median follow-up of 4.5 months, incomplete ablation was seen in 1 of 149 lesions treated (0.7%) and local tumor recurrence in 1 lesion (0.7%). The results of this series confirm the safety and feasibility of MTA technology. The 99.3% rate of complete tumor ablation and low rate of local recurrence at short-term follow up are promising. © 2015 Wiley Periodicals, Inc.

  7. Evolution of a laparoscopic liver resection program: an analysis of 203 cases.

    Science.gov (United States)

    Elshamy, Mohammed; Takahashi, Hideo; Akyuz, Muhammet; Yazici, Pinar; Yigitbas, Hakan; Hammad, Abdulrahman Y; Aucejo, Federico N; Quintini, Cristiano; Fung, John; Berber, Eren

    2017-10-01

    Techniques for laparoscopic liver resection (LLR) have been developed over the past two decades. The aim of this study is to analyze the outcomes and trends of LLR. 203 patients underwent LLR between 2006 and 2015. Trends in techniques and outcomes were assessed dividing the experience into 2 periods (before and after 2011). Tumor type was malignant in 62%, and R0 resection was achieved in 87.7%. Procedures included segmentectomy/wedge resection in 64.5%. Techniques included a purely laparoscopic approach in 59.1% and robotic 12.3%. Conversion to open surgery was necessary in 6.4% cases. Mean hospital stay was 3.7 ± 0.2 days. 90-day mortality was 0% and morbidity 20.2%. Pre-coagulation and the robot were used less often, while the performance of resections for posteriorly located tumors increased in the second versus the first period. This study confirms the safety and efficacy of LLR, while describing the evolution of a program regarding patient and technical selection. With building experience, the number of resections performed for posteriorly located tumors have increased, with less reliance on pre-coagulation and the robot.

  8. Initial experience with a new articulating energy device for laparoscopic liver resection.

    Science.gov (United States)

    Berber, Eren; Akyuz, Muhammet; Aucejo, Federico; Aliyev, Shamil; Aksoy, Erol; Birsen, Onur; Taskin, Eren

    2014-03-01

    Although significant advances have been made in laparoscopic liver resection (LLR), most techniques still rely on multiple energy devices and staplers, which increase operative costs. The aim of this study was to report the initial results of a new multifunctional energy device for hepatic parenchymal transection. Fourteen patients who underwent LLR using this new device were compared to 20 patients who had LLR using current laparoscopic techniques (CL). Data were collected prospectively. The groups were similar demographics and tumor type and size. Although the type of resection was similar between the groups, the parenchymal transection time was less in the Caiman group (32 ± 5 vs. 63 ± 4 min, respectively, p = 0.0001). The operative time was similar (194 ± 21 vs. 233 ± 16 min, respectively, p = 0.158). There was reduction of the number of advanced instrumentation used in the Caiman group, including the staplers. Estimated blood loss, size of surgical margin, and hospital stay were similar. There was no mortality, and morbidity was 7 % in the Caiman and 20 % in the CL group. This initial study shows that the new device is safe and efficient for LLR. Its main advantage is shortening of hepatic parenchymal transection time. This has implications for increasing efficiency and cost saving in LLR.

  9. Robot-assisted radical prostatectomy in Brazil: preliminary results

    Directory of Open Access Journals (Sweden)

    Jose Roberto Colombo Junior

    2009-12-01

    Full Text Available Purpose: To report the initial experience on robot-assisted radical prostatectomy in Brazil. Methods: From March 2008 to March 2009, a hundred patients were treated with robot-assisted radical prostatectomy. Patient’s demographic data, as well as perioperative results of the procedures, are described in this study. Rresults: Patients’ mean age and mean PSA were 58 years and 7.58 ng/ml, respectively. All procedures were performed through transperitoneal approach, with a mean bleeding of 480 mL and surgical time of 298 minutes. A surgical margin affected by cancer was present in 16% of the cases. There were four complications: bleeding requiring transfusion (two cases, rectal perforation corrected on the spot and inadequate functioning of the robot. There was no conversion to another access or obit occurrences in this caseload. Cconclusions: Robot-assisted prostatectomy is a reality in Brazil and the results herein presented demonstrate that this procedure can be safely performed. Long-term follow-up is still necessary to assess the oncological and functional outcomes.

  10. Robot-assisted surgery: the future is here.

    Science.gov (United States)

    Gerhardus, Diana

    2003-01-01

    According to L. Wiley Nifong, director of robotic surgery at East Carolina University's Brody School of Medicine, "Nationally, only one-fourth of the 15 million surgeries performed each year are done with small incisions or what doctors call 'minimally invasive surgery'." Robots could raise that number substantially (Stark 2002). Currently, healthcare organizations use robot technology for thoracic, abdominal, pelvic, and neurological surgical procedures. Minimally invasive surgery reduces the amount of inpatient hospital days, and the computer in the system filters any hand tremors a physician may have during the surgery. The use of robot-assisted surgery improves quality of care because the patient experiences less pain after the surgery. Robot-assisted surgery demonstrates definite advantages for the patient, physician, and hospital; however, healthcare organizations in the United States have yet to acquire the technology because of implementation costs and the lack of FDA (Food and Drug Administration) approval for using the technology for certain types of heart procedures. This article focuses on robot-assisted surgery advantages to patients, physicians, and hospitals as well as on the disadvantages to physicians. In addition, the article addresses implementation costs, which creates financial hurdles for most healthcare organizations; offers recommendations for administrators to embrace this technology for strategic positioning; and enumerates possible roles for robots in medicine.

  11. Robotic-assisted partial Nephrectomy: initial experience in South America

    Directory of Open Access Journals (Sweden)

    Gustavo C. Lemos

    2011-08-01

    Full Text Available OBJECTIVE:To report the initial outcomes of robotic-assisted partial nephrectomy in a tertiary center in South America. MATERIAL AND METHODS: From 11/2008 to 12/2009, a total of 16 transperitoneal robotic-assisted partial nephrectomies were performed in 15 patients to treat 18 kidney tumors. One patient with bilateral tumor had two procedures, while two patients with two synchronous unilateral tumors had a single operation to remove them. Eleven (73% patients were male and the right kidney was affected in 7 (46% patients. The median patient age and tumor size were 57 years old and 30 mm, respectively. Five (28% tumors were hilar and/or centrally located. RESULTS: The median operative time, warm ischemia time and estimated blood loss was 140 min, 27 min and 120 mL, respectively. Blood transfusion was required in one patient with bilateral tumor, and one additional pyelolithotomy was performed due to a 15mm stone located in the renal pelvis. The histopathology analysis showed 15 (83% malignant tumors, which 10 (67% were clear cell carcinoma. The median hospital stay was 72 hrs and no major complication was observed. CONCLUSION: Robotic-assisted partial nephrectomy is safe and represents a valuable option to perform minimally invasive nephron-sparing surgery.

  12. Long-term quality of life and outcomes following robotic assisted TAPP inguinal hernia repair.

    Science.gov (United States)

    Iraniha, Andrew; Peloquin, Joshua

    2018-06-01

    Laparoscopic TAPP inguinal hernia repair is an established alternative to open hernia repair, which offers equivalent outcomes with less postoperative pain and faster recovery. Unfortunately, it remains technically challenging, requiring advanced laparoscopic skills which have limited its popularity among surgeons. The robotic platform has the potential to overcome these challenges. The objective of this study was to examine the long-term quality of life and outcomes following robotic assisted TAPP inguinal hernia repair, since these data have not been reported up to now. From October 2012 to October 2015, 159 inguinal hernias in 82 consecutive patients were repaired with 3D mesh (BARD) using da Vinci Si Surgical System (Intuitive Surgical, Sunnyvale, CA, USA). The patients' demographics and intraoperative data were documented. Patients were seen 2 and 6 weeks after the surgery and the complications were recorded. Patients were assessed 6 weeks after the surgery by a survey using a universal pain assessment tool to document their post-operative pain, narcotic use and time of return to work and exercise. A modified short form 12 (SF 12) was also sent out to the patients 12-36 months after the surgery to measure their health-related quality of life prior to surgery and at the 12- to 36-month follow-up, and to document any evidence of recurrence. Postoperative health-related quality of life scores were compared to the pre-operative baseline quality of life scores using the unpaired t test. Over the course of 3 years, 159 robotic assisted TAPP inguinal hernia repair were performed in 82 patients, 73 men and 9 women by one surgeon as an outpatient basis. The mean age was 53 and mean body mass index was 26. There were no intraoperative complications or conversions. The average operative time was 99 min. Four patients developed urinary retention post-operatively and one patient developed postoperative bowel obstruction requiring laparoscopic lysis of adhesion with no

  13. Occult Radiographically Evident Port-Site Hernia After Robot-Assisted Urologic Surgery: Incidence and Risk Factors.

    Science.gov (United States)

    Christie, Matthew C; Manger, Jules P; Khiyami, Abdulaziz M; Ornan, Afshan A; Wheeler, Karen M; Schenkman, Noah S

    2016-01-01

    Laparoscopic trocar-site hernias (TSH) are rare, with a reported incidence of 1% or less. The incidence of occult radiographically evident hernias has not been described after robot-assisted urologic surgery. We evaluated the incidence and risk factors of this problem. A single-institution retrospective review of robot-assisted urologic surgery was performed from April 2009 to December 2012. Patients with preoperative and postoperative CT were included for analysis. Imaging was reviewed by two radiologists and one urologist. One hundred four cases were identified, including 60 partial nephrectomy, 38 prostatectomy, and 6 cystectomy. Mean age was 58 years and mean body mass index (BMI) was 29 kg/m(2). The cohort was 77% male. Ten total hernias were identified by CT in 8 patients, 2 of which were clinically evident hernias. Excluding these two hernias, occult port-site hernias were identified radiographically in seven patients. Per-patient incidence of occult TSH was 6.7% (7/104), and per-port incidence was 1.4% (8/564). All hernias were midline and 30% contained bowel. Eight of the 10 occurred at 12 mm sites (p = 0.0065) and 3 of the 10 occurred at extended incisions. Age, gender, BMI, smoking status, diabetes mellitus, immunosuppressive drug therapy, ASA score, procedure, blood loss, prior abdominal surgery, and history of hernia were not significant risk factors. Specimen size >40 g (p = 0.024) and wound infection (p = 0.0052) were significant risk factors. While the incidence of clinically evident port-site hernia remains low in robot-assisted urologic surgery, the incidence of CT-detected occult hernia was 6.7% in this series. These occurred most often in sites extended for specimen extraction and at larger port sites. This suggests more attention should be paid to fascial closure at these sites.

  14. A Dynamic Non Energy Storing Guidance Constraint with Motion Redirection for Robot Assisted Surgery

    Science.gov (United States)

    2016-12-01

    move during the operation. Robot -assisted beating heart surgery is an example of procedures that can benefit from dynamic constraints. Their...A Dynamic Non-Energy-Storing Guidance Constraint with Motion Redirection for Robot -Assisted Surgery Nima Enayati, Eva C. Alves Costa, Giancarlo...Momi, and G. Ferrigno, “Haptics in Robot -Assisted Surgery : Challenges and Benefits,” IEEE Rev. Biomed. Eng., 2016. [2] L. B. Rosenberg, “Virtual

  15. Rare Case of an Epithelial Cyst in an Intrapancreatic Accessory Spleen Treated by Robot-Assisted Spleen Preserving Distal Pancreatectomy.

    Science.gov (United States)

    van Dijck, Willemijn P M; Groot, Vincent P; Brosens, Lodewijk A A; Hagendoorn, Jeroen; Rinkes, Inne H M Borel; van Leeuwen, Maarten S; Molenaar, I Quintus

    2016-01-01

    Epithelial cyst in an intrapancreatic accessory spleen (ECIPAS) is exceedingly rare with only 57 cases reported since the first publication in 1980. Comprehensive clinical and diagnostic features remain to be clarified. We present a case of ECIPAS in a 21-year-old Philippine woman who was admitted with right upper quadrant abdominal pain. A cystic lesion in the pancreatic tail was discovered and evaluated by computed tomography and magnetic resonance images. Based on clinical and radiological features a solid pseudopapillary neoplasm was suspected. The patient underwent robot-assisted spleen preserving distal pancreatectomy. Pathological evaluation revealed a 26 mm intrapancreatic accessory spleen with a 16 mm cyst, lined by multilayered epithelium in the tail of the pancreas. The postoperative course was uneventful. Differentiating ECIPAS from (pre)malignant cystic pancreatic neoplasms based on clinical and radiological features remains difficult. When typical radiological signs can be combined with scintigraphy using Technetium-99m labelled colloid or Technetium-99m labelled erythrocytes, which can identify the solid component of the lesion as splenic tissue, it should be possible to make the right diagnosis noninvasively. When pancreatectomy is inevitable due to symptoms or patient preference, minimally invasive laparoscopic or robot-assisted spleen preserving distal pancreatectomy should be considered.

  16. Rare Case of an Epithelial Cyst in an Intrapancreatic Accessory Spleen Treated by Robot-Assisted Spleen Preserving Distal Pancreatectomy

    Directory of Open Access Journals (Sweden)

    Willemijn P. M. van Dijck

    2016-01-01

    Full Text Available Epithelial cyst in an intrapancreatic accessory spleen (ECIPAS is exceedingly rare with only 57 cases reported since the first publication in 1980. Comprehensive clinical and diagnostic features remain to be clarified. We present a case of ECIPAS in a 21-year-old Philippine woman who was admitted with right upper quadrant abdominal pain. A cystic lesion in the pancreatic tail was discovered and evaluated by computed tomography and magnetic resonance images. Based on clinical and radiological features a solid pseudopapillary neoplasm was suspected. The patient underwent robot-assisted spleen preserving distal pancreatectomy. Pathological evaluation revealed a 26 mm intrapancreatic accessory spleen with a 16 mm cyst, lined by multilayered epithelium in the tail of the pancreas. The postoperative course was uneventful. Differentiating ECIPAS from (premalignant cystic pancreatic neoplasms based on clinical and radiological features remains difficult. When typical radiological signs can be combined with scintigraphy using Technetium-99m labelled colloid or Technetium-99m labelled erythrocytes, which can identify the solid component of the lesion as splenic tissue, it should be possible to make the right diagnosis noninvasively. When pancreatectomy is inevitable due to symptoms or patient preference, minimally invasive laparoscopic or robot-assisted spleen preserving distal pancreatectomy should be considered.

  17. [Individual learning curve for radical robot-assisted prostatectomy based on the example of three professionals working in one clinic].

    Science.gov (United States)

    Rasner, P I; Pushkar', D Iu; Kolontarev, K B; Kotenkov, D V

    2014-01-01

    The appearance of new surgical technique always requires evaluation of its effectiveness and ease of acquisition. A comparative study of the results of the first three series of successive robot-assisted radical prostatectomy (RARP) performed on at time by three surgeons, was conducted. The series consisted of 40 procedures, and were divided into 4 groups of 10 operations for the analysis. When comparing data, statistically significant improvement of intra- and postoperative performance in each series was revealed, with increase in the number of operations performed, and in each subsequent series compared with the preceding one. We recommend to perform the planned conversion at the first operation. In our study, previous laparoscopic experience did not provide any significant advantages in the acquisition of robot-assisted technology. To characterize the individual learning curve, we recommend the use of the number of operations that the surgeon looked in the life-surgery regimen and/or in which he participated as an assistant before his own surgical activity, as well as the indicator "technical defect". In addition to the term "individual learning curve", we propose to introduce the terms "surgeon's individual training phase", and "clinic's learning curve".

  18. Exploring the effects of dimensionality reduction in deep networks for force estimation in robotic-assisted surgery

    Science.gov (United States)

    Aviles, Angelica I.; Alsaleh, Samar; Sobrevilla, Pilar; Casals, Alicia

    2016-03-01

    Robotic-Assisted Surgery approach overcomes the limitations of the traditional laparoscopic and open surgeries. However, one of its major limitations is the lack of force feedback. Since there is no direct interaction between the surgeon and the tissue, there is no way of knowing how much force the surgeon is applying which can result in irreversible injuries. The use of force sensors is not practical since they impose different constraints. Thus, we make use of a neuro-visual approach to estimate the applied forces, in which the 3D shape recovery together with the geometry of motion are used as input to a deep network based on LSTM-RNN architecture. When deep networks are used in real time, pre-processing of data is a key factor to reduce complexity and improve the network performance. A common pre-processing step is dimensionality reduction which attempts to eliminate redundant and insignificant information by selecting a subset of relevant features to use in model construction. In this work, we show the effects of dimensionality reduction in a real-time application: estimating the applied force in Robotic-Assisted Surgeries. According to the results, we demonstrated positive effects of doing dimensionality reduction on deep networks including: faster training, improved network performance, and overfitting prevention. We also show a significant accuracy improvement, ranging from about 33% to 86%, over existing approaches related to force estimation.

  19. Routine testing of liver function before and after elective laparoscopic cholecystectomy: is it necessary?

    LENUS (Irish Health Repository)

    Ahmad, Nasir Zaheer

    2012-01-31

    BACKGROUND AND OBJECTIVES: Liver function tests (LFTs) include alanine aminotransferase (ALT), aspartate aminotransferase (AST), gamma-glutamyl transpeptidase (GGT), alkaline phosphatase (ALP), and bilirubin. The role of routine testing before and after laparoscopic cholecystectomy was evaluated in this study. PATIENTS AND METHODS: A total of 355 patients were retrospectively analyzed by examining the LFTs the day before, the day after, and 3 weeks after the surgery. The Wilcoxon signed-rank test and Student t test were performed to determine statistical significance. RESULTS: Alterations in the serum AST, ALT, and GGT were seen on the first postoperative day. Minor changes were seen in bilirubin and ALP. An overall disturbance in the LFTs was seen in more than two-thirds of the cases. Repeat LFTs performed after 3 weeks on follow-up were found to be within normal limits. CONCLUSION: Mild-to-moderate elevation in preoperative LFTs may not be associated with any deleterious effect, and, in the absence of clinical indications, routine preoperative or postoperative liver function testing is unnecessary.

  20. Two-stage liver transplantation using auxiliary laparoscopically harvested grafts in adults: Emphasizing the concept of "hypersmall graft nursing".

    Science.gov (United States)

    Scatton, Olivier; Cauchy, François; Conti, Filomena; Perdigao, Fabiano; Massault, Pierre Philippe; Goumard, Claire; Soubrane, Olivier

    2016-11-01

    Living donor liver transplantation is limited by the donor's risk in case of right liver donation and by the risk of small-for-size syndrome on the recipient in case of left lobe transplantation. This study aimed at evaluating the feasibility and results of two-stage liver transplantation using auxiliary hyper small grafts harvested laparoscopically and discussing relevant technical insights and issues that still need to be overcome. Retrospective analysis involving two patients operated at a tertiary referral center. The recipients underwent left lateral sectionectomy and then auxillary liver transplantation using laparoscopically harvested left lateral section. The native right liver was transiently left in place to sustain the initially small functional graft functional during its hypertrophy. No donor experienced postoperative complication. After 7days, the hypertrophy rate was 112% (105-120). Doppler assessments during the first two postoperative weeks showed progressive portal vein inflow decrease in the right native livers and portal vein inflow increase in the grafts. Liver biopsies on postoperative day 7 showed no lesion of overperfusion. No recipient experienced liver failure or small-for-size syndrome. Second stage hepatectomy of the native liver was undertaken in one patient. In the other patient, biliary stenosis on postoperative day 30 precluded second stage hepatectomy. This patient required retransplantation after one year. The current strategy increases donor safety and may allow increasing the pool of available grafts. Refinements in the management of the native right liver are however required to improve the feasibility rate of this strategy. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  1. Robotic assisted radical prostatectomy: a different treatment for prostate cancer?

    Directory of Open Access Journals (Sweden)

    Alexandre Den Julio

    2010-09-01

    Full Text Available Considering the Health Care System in Brazil, a developing country,and public healthcare policies, robotic surgery is a reality to veryfew citizens. Therefore, robotic assisted radical prostatectomy isfar removed from the daily practice of the vast majority of Brazilianurologists. Scientific evidence of the superiority of robotic assistedradical prostatectomy does not presently justify public investmentsfor widespread development of robotic centers. Maybe over timeand with reductions in costs, robotic technology will become amore established practice, as observed in other countries, and morefeasible for the Brazilian urological community.

  2. Robot-Assisted Training Early After Cardiac Surgery.

    Science.gov (United States)

    Schoenrath, Felix; Markendorf, Susanne; Brauchlin, Andreas E; Seifert, Burkhardt; Wilhelm, Markus J; Czerny, Martin; Riener, Robert; Falk, Volkmar; Schmied, Christian M

    2015-07-01

    To assess feasibility and safety of a robot-assisted gait therapy with the Lokomat® system in patients early after open heart surgery. Within days after open heart surgery 10 patients were subjected to postoperative Lokomat® training (Intervention group, IG) whereas 20 patients served as controls undergoing standard postoperative physiotherapy (Control group, CG). All patients underwent six-minute walk test and evaluation of the muscular strength of the lower limbs by measuring quadriceps peak force. The primary safety end-point was freedom from any device-related wound healing disturbance. Patients underwent clinical follow-up after one month. Both training methods resulted in an improvement of walking distance (IG [median, interquartile range, p-value]: +119 m, 70-201 m, p = 0.005; CG: 105 m, 57-152.5m, p force (IG left: +5 N, 3.8 7 N, p = 0.005; IG right: +3.5 N, 1.5-8.8 N, p = 0.011; CG left: +5.5 N, 4-9 N, p training were comparable to early postoperative standard in hospital training (median changes in walking distance in percent, p = 0.81; median changes in quadriceps peak force in percent, left: p = 0.97, right p = 0.61). No deep sternal wound infection or any adverse event occurred in the robot-assisted training group. Robot-assisted gait therapy with the Lokomat® system is feasible and safe in patients early after median sternotomy. Results with robot-assisted training were comparable to standard in hospital training. An adapted and combined aerobic and resistance training intervention with augmented feedback may result in benefits in walking distance and lower limb muscle strength (ClinicalTrials.gov number, NCT 02146196). © 2015 Wiley Periodicals, Inc.

  3. Virtual modeling of robot-assisted manipulations in abdominal surgery.

    Science.gov (United States)

    Berelavichus, Stanislav V; Karmazanovsky, Grigory G; Shirokov, Vadim S; Kubyshkin, Valeriy A; Kriger, Andrey G; Kondratyev, Evgeny V; Zakharova, Olga P

    2012-06-27

    To determine the effectiveness of using multidetector computed tomography (MDCT) data in preoperative planning of robot-assisted surgery. Fourteen patients indicated for surgery underwent MDCT using 64 and 256-slice MDCT. Before the examination, a specially constructed navigation net was placed on the patient's anterior abdominal wall. Processing of MDCT data was performed on a Brilliance Workspace 4 (Philips). Virtual vectors that imitate robotic and assistant ports were placed on the anterior abdominal wall of the 3D model of the patient, considering the individual anatomy of the patient and the technical capabilities of robotic arms. Sites for location of the ports were directed by projection on the roentgen-positive tags of the navigation net. There were no complications observed during surgery or in the post-operative period. We were able to reduce robotic arm interference during surgery. The surgical area was optimal for robotic and assistant manipulators without any need for reinstallation of the trocars. This method allows modeling of the main steps in robot-assisted intervention, optimizing operation of the manipulator and lowering the risk of injuries to internal organs.

  4. Toward the art of robotic-assisted vitreoretinal surgery

    Directory of Open Access Journals (Sweden)

    Amir Molaei

    2017-01-01

    Full Text Available New technological progress in robotics has brought many beneficial clinical applications. Currently, computer integrated robotic surgery has gained clinical acceptance for several surgical procedures. Robotically assisted eye surgery is envisaged as a promising solution to overcome the shortcomings inherent to conventional surgical procedures as in vitreoretinal surgeries. Robotics by its high precision and fine mechanical control can improve dexterity, cancel tremor, and allow highly precise remote surgical capability, delicate vitreoretinal manipulation capabilities. Combined with magnified three-dimensional imaging of the surgical site, it can enhance surgical precision. Tele-manipulation can provide the ability for tele-surgery or haptic feedback of forces generated by the manipulation of intraocular tissues. It presents new solutions for some sight-threatening conditions such as retinal vein cannulation where, due to physiological limitations of the surgeon's hand, the procedure cannot be adequately performed. In this paper, we provide an overview of the research and advances in robotically assisted vitreoretinal eye surgery. Additionally the barriers to the integration of this method in the field of ocular surgery are summarized. Finally, we discuss the possible applications of the method in the area of vitreoretinal surgery.

  5. A Perspective on Robotic Assistance for Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    Nathan A. Netravali

    2013-01-01

    Full Text Available Knee arthroplasty is used to treat patients with degenerative joint disease of the knee to reduce pain and restore the function of the joint. Although patient outcomes are generally quite good, there are still a number of patients that are dissatisfied with their procedures. Aside from implant design which has largely become standard, surgical technique is one of the main factors that determine clinical results. Therefore, a lot of effort has gone into improving surgical technique including the use of computer-aided surgery. The latest generation of orthopedic surgical tools involves the use of robotics to enhance the surgeons’ abilities to install implants more precisely and consistently. This review presents an evolution of robot-assisted surgical systems for knee replacement with an emphasis on the clinical results available in the literature. Ever since various robotic-assistance systems were developed and used clinically worldwide, studies have demonstrated that these systems are as safe as and more accurate than conventional methods of manual implantation. Robotic surgical assistance will likely result in improved surgical technique and improved clinical results.

  6. What is the best technique in parenchymal transection in laparoscopic liver resection? Comprehensive review for the clinical question on the 2nd International Consensus Conference on Laparoscopic Liver Resection.

    Science.gov (United States)

    Otsuka, Yuichiro; Kaneko, Hironori; Cleary, Sean P; Buell, Joseph F; Cai, Xiujun; Wakabayashi, Go

    2015-05-01

    The continuing evolution of technique and devices used in laparoscopic liver resection (LLR) has allowed successful application of this minimally invasive surgery for the treatment of liver disease. However, the type of instruments by energy sources and technique used vary among each institution. We reviewed the literature to seek the best technique for parenchymal transection, which was proposed as one of the important clinical question in the 2nd International Consensus Conference on LLR held on October 2014. While publications have described transection techniques used in LLR from 1991 to June 2014, it is difficult to specify the best technique and device for laparoscopic hepatic parenchymal transection, owing to a lack of randomized trials with only a small number of comparative studies. However, it is clear that instruments should be used in combination with others based on their functions and the depth of liver resection. Most authors have reported using staplers to secure and divide major vessels. Preparation for prevention of unexpected hemorrhaging particularly in liver cirrhosis, the Pringle's maneuver and prompt technique for hemostasis should be performed. We conclude that hepatobiliary surgeons should select techniques based on their familiarity with a concrete understanding of instruments and individualize to the procedure of LLR. © 2015 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  7. Videocirurgia colorretal com assistência robótica: o próximo passo? Robotic assisted colorrectal surgery

    Directory of Open Access Journals (Sweden)

    Sergio Eduardo Alonso Araujo

    2008-09-01

    Full Text Available O desenvolvimento de técnicas minimamente invasivas é um dos mais importantes avanços da cirurgia colorretal. A assistência robótica integra o arsenal de técnicas em cirurgia minimamente invasiva, e vem sendo aplicado em cirurgia colorretal por um restrito grupo de cirurgiões em alguns centros ao redor do mundo com resultados iniciais que merecem atenção. O objetivo do presente estudo é analisar os resultados do emprego da assistência robótica em videocirurgia colorretal. Dentre as vantagens associadas ao emprego de robôs em videocirurgia colorretal, figuram o incremento na precisão dos movimentos e a visão tridimensional. A experiência clínica é ainda pequena, e advém de uma série de casos e estudos comparativos com a videocirurgia colorretal sem assistência robótica com ainda pequeno número de casos. A dissecção pélvica com incremento da preservação autonômica parece ser a maior vantagem associada à assistência robótica em videocirurgia colorretal. Somente através do treinamento de um número mais representativo de cirurgiões colorretais, bem como com a expansão da experiência clínica será possível prever com maior precisão o papel da assistência robótica em videocirurgia colorretal.The development of minimally invasive surgical techniques represents an important aspect of modern surgical research. Robot-assisted minimally invasive colorectal surgery represents a way of assisting laparoscopic colorectal procedures. Robotic technology overcomes some of these limitations by successfully providing intuitive motion and enhanced precision and accuracy, in an environment that is much more ergonomic. A restrict number of surgeons in specialized centers around the world have been applying robotics. In this review, current evidence about different technologies and its place in colorectal surgery is evaluated. The feasibility of performing robot-assisted colorectal operations has been demonstrated though case

  8. Laparoscopic and robotic nephroureterectomy

    DEFF Research Database (Denmark)

    Azawi, Nessn H; Berg, Kasper Drimer; Thamsborg, Andreas Key Milan

    2017-01-01

    nephroureterectomy between January 2008 and December 2014 was conducted. Outcome measures were OS and CSM. RESULTS: In total, 298 patients underwent robot-assisted or laparoscopic radical nephroureterectomy with a final histological diagnosis of UTUC. LND was performed in 46 (15.4%). One hundred and seventy...... in the selection of patients undergoing LND. CONCLUSIONS: Five-year OS and CSM are comparable between patients with N1 and N0 MID. This evidence may support the use of the LND procedure in patients with muscle-invasive UTUC....

  9. Laparoscopic Repair of Incisional Hernia Following Liver Transplantation-Early Experience of a Single Institution in Taiwan.

    Science.gov (United States)

    Kuo, S-C; Lin, C-C; Elsarawy, A; Lin, Y-H; Wang, S-H; Wu, Y-J; Chen, C-L

    2017-10-01

    Ventral incisional hernia (VIH) is not uncommon following liver transplantation. Open repair was traditionally adopted for its management. Laparoscopic repair of VIH has been performed successfully in nontransplant patients with evidence of reduced recurrence rates and hospital stay. However, the application of VIH in post-transplantation patients has not been well established. Herein, we provide our initial experience with laparoscopic repair of post-transplantation VIH. From March 2015 to March 2016, 18 cases of post-transplantation VIH were subjected to laparoscopic repair (laparoscopy group). A historical control group of 17 patients who underwent conventional open repair (open group) from January 2013 to January 2015 were identified for comparison. The demographics and clinical outcomes were retrospectively compared. There were no significant differences among basic demographics between the 2 groups. No conversion was recorded in the laparoscopy group. Recurrence of VIH up to the end of the study period was not noted. In the laparoscopy group, the minor complications were lower (16.7% vs 52.9%; P = .035), the length of hospital stay was shorter (3 d vs 7 d, P = .007), but the median operative time was longer (137.5 min vs 106 min; P = .003). Laparoscopic repair of post-transplantation VIH is a safe and feasible procedure with shorter length of hospital stay. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Local recurrence after laparoscopic radiofrequency ablation of malignant liver tumors: Results of a contemporary series.

    Science.gov (United States)

    Takahashi, Hideo; Akyuz, Muhammet; Aksoy, Erol; Karabulut, Koray; Berber, Eren

    2017-06-01

    The aims of this study were to determine the incidence of Local recurrence (LR) in patients at long-term follow-up after laparoscopic RFA (LRFA) and also to determine the risk factors for LR from a contemporary series. Patients undergoing LRFA between 2005 and 2014 by a single surgeon were reviewed. Demographic and perioperative data were analyzed from a prospective database. LRFA was performed on 316 patients with 901 lesions. Median follow-up was 25 months, with 76% of whom completed at least one year of follow-up. The LR rate was 18.4%. The LR in patients followed for less than 12 months was 13.8%, 20.3% for 12 months, and 19.7% for 18 months (P = 0.02). One-fourth of the LRs developed after the 1st year. Morbidity was 8.9% and mortality 0.3%. Tumor type, size, ablation margin, and surgeon experience affected LR, with tumor type, size, and ablation margin being independent. This study shows that 14% of malignant liver tumors will develop LR within a year after LRFA. Additional 4% of the lesions will demonstrate recurrence within 1 cm of the ablation zone, mostly as part of a multifocal recurrence. Ablation margin is the only parameter that the surgeon can manipulate to decrease LR. © 2017 Wiley Periodicals, Inc.

  11. Robot-assisted Partial Nephrectomy: 5-yr Oncological Outcomes at a Single European Tertiary Cancer Center.

    Science.gov (United States)

    Vartolomei, Mihai Dorin; Matei, Deliu Victor; Renne, Giuseppe; Tringali, Valeria Maria; Crisan, Nicolae; Musi, Gennaro; Mistretta, Francesco Alessandro; Russo, Andrea; Cozzi, Gabriele; Cordima, Giovani; Luzzago, Stefano; Cioffi, Antonio; Di Trapani, Ettore; Catellani, Michele; Delor, Maurizio; Bottero, Danilo; Imbimbo, Ciro; Mirone, Vincenzo; Ferro, Matteo; de Cobelli, Ottavio

    2017-10-27

    Nowadays, there is a debate about which surgical treatment should be best for clinical T1 renal tumors. If the oncological outcomes are considered, there are many open and laparoscopic series published. As far as robotic series are concerned, only a few of them report 5-yr oncological outcomes. The aim of this study was to analyze robot-assisted partial nephrectomy (RAPN) midterm oncological outcomes achieved in a tertiary robotic reference center. Between April 2009 and September 2013, 123 consecutive patients with clinical T1-stage renal masses underwent RAPN in our tertiary cancer center. Inclusion criteria were as follows: pathologically confirmed renal cell carcinomas (RCCs) and follow-up for >12 mo. Eighteen patients were excluded due to follow-up of <12 mo and 15 due to benign final pathology. Median follow-up was 59 mo (interquartile range 44-73 mo). Patients were followed according to guideline recommendations and institutional protocol. Outcomes were measured by time to disease progression, overall survival, or time to cancer-specific death. Kaplan-Meier method was used to estimate survival; log-rank tests were applied for pair-wise comparison of survival. From the 90 patients included, 66 (73.3%) had T1a, 12 (13.3%) T1b, three (3.3%) T2a, and nine (10%) T3a tumors. Predominant histological type was clear cell carcinoma: 67 (74.5%). Fuhrmann grade 1 and 2 was found in 73.3% of all malignant tumors. Two patients (2.2%) had positive surgical margins, and complication rate was 17.8%. Relapse rate was 7.7%, including two cases (2.2%) of local recurrences and five (5.5%) distant metastasis. Five-year disease-free survival was 90.9%, 5-yr cancer-specific survival was 97.5%, and 5-yr overall survival was 95.1%. Midterm oncological outcomes after RAPN for localized RCCs (predominantly T1a tumors of low anatomic complexity) were shown to be good, adding significant evidence to support the oncological efficacy and safety of RAPN for the treatment of this type of

  12. Instrumental tactile diagnostics in robot-assisted surgery

    Directory of Open Access Journals (Sweden)

    Solodova RF

    2016-10-01

    Full Text Available Rozalia F Solodova,1,2 Vladimir V Galatenko,1,2 Eldar R Nakashidze,3 Igor L Andreytsev,3 Alexey V Galatenko,1 Dmitriy K Senchik,2 Vladimir M Staroverov,1 Vladimir E Podolskii,1,2 Mikhail E Sokolov,1,2 Victor A Sadovnichy1,2 1Faculty of Mechanics and Mathematics, 2Institute of Mathematical Studies of Complex Systems, Lomonosov Moscow State University, 31st Surgery Department, Clinical Hospital 31, Moscow, Russia Background: Robotic surgery has gained wide acceptance due to minimizing trauma in patients. However, the lack of tactile feedback is an essential limiting factor for the further expansion. In robotic surgery, feedback related to touch is currently kinesthetic, and it is mainly aimed at the minimization of force applied to tissues and organs. Design and implementation of diagnostic tactile feedback is still an open problem. We hypothesized that a sufficient tactile feedback in robot-assisted surgery can be provided by utilization of Medical Tactile Endosurgical Complex (MTEC, which is a novel specialized tool that is already commercially available in the Russian Federation. MTEC allows registration of tactile images by a mechanoreceptor, real-time visualization of these images, and reproduction of images via a tactile display. Materials and methods: Nine elective surgeries were performed with da Vinci™ robotic system. An assistant performed tactile examination through an additional port under the guidance of a surgeon during revision of tissues. The operating surgeon sensed registered tactile data using a tactile display, and the assistant inspected the visualization of tactile data. First, surgeries where lesion boundaries were visually detectable were performed. The goal was to promote cooperation between the surgeon and the assistant and to train them in perception of the tactile feedback. Then, instrumental tactile diagnostics was utilized in case of visually undetectable boundaries. Results: In robot-assisted surgeries where lesion

  13. Percutaneous Sacroiliac Screw Placement: A Prospective Randomized Comparison of Robot-assisted Navigation Procedures with a Conventional Technique

    Directory of Open Access Journals (Sweden)

    Jun-Qiang Wang

    2017-01-01

    Conclusions: Accuracy of the robot-assisted technique was superior to that of the freehand technique. Robot-assisted navigation is safe for unstable posterior pelvic ring stabilization, especially in S1, but also in S2. SI screw insertion with robot-assisted navigation is clinically feasible.

  14. Anesthetic management of robot-assisted thoracoscopic thymectomy

    Directory of Open Access Journals (Sweden)

    Anil Karlekar

    2016-01-01

    Full Text Available Myasthenia gravis (MG is a rare disorder involving neuromuscular junction. In conjunction with medical therapy, thymectomy is a known modality of treatment of MG and has shown to increase the probability of remission and overall symptomatic improvement. For minimally invasive thymectomy, video-.assisted thoracoscopic surgery has been the preferred surgical approach till recently. The robotic surgical procedure must necessarily bring new challenges to the anesthesiologists to effectively meet the specific requirements of the technique. At present, there is a paucity of literature regarding the anesthetic concerns of robotic assisted thymectomy, patient in question specifically posed a challenge since different maneuvers and techniques had to be tried to obtain optimum surgical conditions with stable ventilatory and hemodynamic parameters. Concerns of patient positioning and hemodynamic monitoring have also been discussed.

  15. Transoral robotic assisted resection of the parapharyngeal space.

    Science.gov (United States)

    Mendelsohn, Abie H

    2015-02-01

    Preliminary case series have reported clinical feasibility and safety of a transoral minimally invasive technique to approach parapharyngeal space masses. With the assistance of the surgical robotic system, tumors within the parapharyngeal space can now be excised safely without neck incisions. A detailed technical description is included. After developing compressive symptoms from a parapharyngeal space lipomatous tumor, the patient was referred by his primary otolaryngologist because of poor open surgical access to the nasopharyngeal component of the tumor. Transoral robotic assisted resection of a 54- × 46-mm parapharyngeal space mass was performed, utilizing 97 minutes of robotic surgical time. Pictorial demonstration of the robotic resection is provided. Parapharyngeal space tumors have traditionally been approached via transcervical skin incisions, typically including blunt dissection from tactile feedback. The transoral robotic approach offers magnified 3D visualization of the parapharyngeal space that allows for complete and safe resection. © 2014 Wiley Periodicals, Inc.

  16. Robotic-Assisted Live Donor Ileal Segmentectomy for Intestinal Transplantation

    Directory of Open Access Journals (Sweden)

    Guosheng Wu, MD, PhD

    2017-10-01

    Full Text Available Background. Every effort should be made to optimize surgical techniques and to minimize potential morbidity rates associated with live donor operations. Advances in a minimally invasive approach by robotic surgery to donor nephrectomy have raised the possibility of applying this technique to live donor bowel resections for intestinal transplantation. Methods. We report the first 5 consecutive cases of a robotic-assisted live donor ileal segmentectomy. We describe the technical aspects of the procedure, discuss the rationale for considering this option, and evaluate potential advantages of this approach. Results. We found that this new approach is associated with less postoperative discomfort, a shorter hospital length of stay, and a faster recovery of bowel function compared to our previous open surgery. Conclusions. Our initial experience suggests that robotic surgery is a safe and feasible procedure for live donor ileal resection for intestinal transplantation and is a useful alternative to conventional open surgery.

  17. Technique of Robotic-assisted Total Proctocolectomy with Lymphadenectomy and Ileal Pouch-Anal Anastomosis for Transverse Colitic Cancer of Ulcerative Colitis, Using the Single Cart Position.

    Science.gov (United States)

    Hanai, Tsunekazu; Maeda, Koutarou; Masumori, Koji; Katsuno, Hidetoshi; Matsuoka, Hiroshi

    2015-11-01

    Robotic surgery offers advantages for operating in a narrow space such as inside the pelvis. We report on the technique of robotic-assisted laparoscopic total proctocolectomy with lymphadenectomy and ileal pouch-anal anastomosis for ulcerative colitis with transverse colitic cancer, using the single cart position. A 46-year-old female patient was diagnosed with colitic cancer of the transverse colon during the surveillance of ulcerative colitis. Six port sites were used. Mobilization of the left-sided colon through to the rectum and mobilization of the transverse colon with lymphadenectomy around the middle colic artery were performed using the robotic surgical system. After rectal mobilization was conducted near the anus, the right side of the colon was mobilized and the ileum resected laparoscopically. Thereafter, a mucosectomy of the proctorectum was carried out through a trans-anal approach, and a hand-sewn J-pouch was performed. Finally, a diverting ileostomy was constructed through the right lower abdomen. The operative time was 460 minutes, including the console time of 361 minutes. The amount of blood loss was 76 g. The patient was discharged on postoperative day nine. Pathological results demonstrated that the depth of the lesion was T3, and the positive lymph node was 1 of 115 retrieved lymph nodes. There were no complications or mortality. Robotic-assisted total proctocolectomy and lymphadenectomy with ileal pouch-anal anastomosis for transverse colitic cancer of ulcerative colitis was performed safely using the single cart position.

  18. Robotic-Assisted Unicompartmental Knee Arthroplasty: State-of-the Art and Review of the Literature.

    Science.gov (United States)

    Christ, Alexander B; Pearle, Andrew D; Mayman, David J; Haas, Steven B

    2018-03-16

    Unicompartmental knee arthroplasty is a successful treatment for unicompartmental knee osteoarthritis that has lower complication rates, faster recovery, and a more natural feeling knee compared to total knee arthroplasty. However, long-term survival has been a persistent concern. As more surgeon-controlled variables have been linked to survival, interest in robotic-assisted surgery has continued to grow. A review and synthesis of the literature on the subject of robotic-assisted unicompartmental knee arthroplasty was performed. We present the driving factors behind the development of robotic-assisted techniques in unicompartmental knee arthroplasty and the current state-of-the art. The ability of surgeons to achieve intraoperative targets with robotic assistance and the outcomes of robotic-assisted surgery are also described. Robotic-assisted surgery has become increasingly popular in unicompartmental knee arthroplasty, as it allows surgeons to more accurately and reproducibly plan and achieve operative targets during surgery. Cost remains a concern, and it remains to be seen whether robotic-assisted surgery will improve long-term survivorship after unicompartmental knee arthroplasty. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. Evaluation of the use of laparoscopic-guided cholecystocholangiography and liver biopsy in definitive diagnosis of neonatal cholestatic jaundice

    Directory of Open Access Journals (Sweden)

    Khalid Shreef

    2016-01-01

    Full Text Available Background: Once it is established that a jaundiced infant has direct hyperbilirubinemia, the principal diagnostic concern is to differentiate hepatocellular from obstructive cholestasis. Traditional tests such as ultrasonography, percutaneous liver biopsy and technetium 99 m hepatobiliary iminodiacetic acid (HIDA scan are often not sufficiently discriminating. Definitive exclusion of biliary atresia (BA in the infant with cholestatic jaundice usually requires mini-laparotomy and intra-operative cholangiography. This approach has many drawbacks because those sick infants are subjected to a time-consuming procedure with the probability of negative surgical exploration. Aim of the Study: The aim of this study was to determine the feasibility of laparoscopic-guided cholecystocholangiography (LGCC and its accuracy and safety in the diagnosis of BA and thus preventing unnecessary laparotomy in infants whose cholestasis is caused by diseases other than BA. Patients and Methods: Twelve cholestatic infants with direct hyperbilirubinemia subjected to LGCC (age, 7–98 days; mean, 56 days after ultrasound scan and (99 mTc HIDA scan and percutaneous liver biopsy failed to provide the definitive diagnosis. Results: One patient had completely absent gall bladder (GB so the laparoscopic procedure was terminated and laparotomy was done (Kasai operation. Four patients had small size GB; they underwent LGCC that showed patent common bile duct with atresia of common hepatic duct, so laparotomy and Kasai operation was performed. Seven patients had well-developed GB, LGCC revealed patent biliary tree, so laparoscopic liver biopsies were taken for histopathology. Five of those patients had neonatal hepatitis, and two had cholestasis as a complication of prolonged TPN. No perioperative complications or mortalities were recorded. Conclusion: When the diagnosis neonatal cholestasis remains elusive after traditional investigations, LGCC is an accurate and simple method

  20. Laparoscopic versus Open Liver Resection: Differences in Intraoperative and Early Postoperative Outcome among Cirrhotic Patients with Hepatocellular Carcinoma—A Retrospective Observational Study

    Directory of Open Access Journals (Sweden)

    Antonio Siniscalchi

    2014-01-01

    Full Text Available Introduction. Laparoscopic liver resection is considered risky in cirrhotic patients, even if minor surgical trauma of laparoscopy could be useful to prevent deterioration of a compromised liver function. This study aimed to identify the differences in terms of perioperative complications and early outcome in cirrhotic patients undergoing minor hepatic resection for hepatocellular carcinoma with open or laparoscopic technique. Methods. In this retrospective study, 156 cirrhotic patients undergoing liver resection for hepatocellular carcinoma were divided into two groups according to type of surgical approach: laparoscopy (LS group: 23 patients or laparotomy (LT group: 133 patients. Perioperative data, mortality, and length of hospital stay were recorded. Results. Groups were matched for type of resection, median number of nodules, and median diameter of largest lesions. Groups were also homogeneous for preoperative liver and renal function tests. Intraoperative haemoglobin decrease and transfusions of red blood cells and fresh frozen plasma were significantly lower in LS group. MELD score lasted stable after laparoscopic resection, while it increased in laparotomic group. Postoperative liver and renal failure and mortality were all lower in LS group. Conclusions. Lower morbidity and mortality, maintenance of liver function, and shorter hospital stay suggest the safety and benefit of laparoscopic approach.

  1. Laparoscopic liver resection for hepatocellular carcinoma in cirrhotic patients. Feasibility of nonanatomic resection in difficult tumor locations

    Directory of Open Access Journals (Sweden)

    Marco Casaccia

    2011-01-01

    Full Text Available Background: Surgical resection for hepatocellular carcinoma (HCC in cirrhotic patients remains controversial because of high morbidity and recurrence rates. Laparoscopic resection of liver tumors has recently been developed and could reduce morbidity. The aim of this study was to evaluate retrospectively our results for laparoscopic liver resection (LLR for HCC including lesions in the posterosuperior segments of the liver in terms of feasibility, outcome, recurrence and survival. Materials and Methods: Between June 2005 and February 2009, we performed 20 LLR for HCC. Median age of the patients was 66 years. The underlying cirrhosis was staged as Child A in 17 cases and Child B in 3. Results: LLR included anatomic resection in six cases and nonanatomic resection in 14. Eleven procedures were associated in nine (45% patients. Median tumor size and surgical margins were 3.1 cm and 15 mm, respectively. A conversion to laparotomy occurred in one (5% patient for hemorrhage. Mortality and morbidity rates were 0% and 15% (3/20. Median hospital stay was 8 days (range: 5-16 days. Over a mean follow-up period of 26 months (range: 19-62 months, 10 (50% patients presented recurrence, mainly at distance from the surgical site. Treatment of recurrence was possible in all the patients, including orthotopic liver transplantation in three cases. Conclusions: LLR for HCC in selected patients is a safe procedure with good short-term results. It can also be proposed in tumor locations with a difficult surgical access maintaining a low morbidity rate and good oncological adequacy. This approach could have an impact on the therapeutic strategy of HCC complicating cirrhosis as a treatment with curative intent or as a bridge to liver transplantation.

  2. Robotically assisted small intestinal strictureplasty in dogs: a survival study involving 16 Heineke-Mikulicz strictureplasties.

    Science.gov (United States)

    Sonoda, T; Lee, S; Whelan, R L; Le, D; Foglia, C; Venturero, M; Hunt, D; Nakajima, K; Milsom, J W

    2007-12-01

    Robotically assisted surgery offers the advantages of improved dexterity and elimination of tremor over conventional laparoscopic surgery. There have been few studies to date, however, examining the role of robotics in intestinal surgery. This study was undertaken to determine the feasibility and safety of using a robotic surgical system in the performance of intracorporeal small bowel strictureplasties in dogs. Using a robotic surgical system, a total of 16 strictureplasties were performed in the small bowel of eight dogs (two strictureplasties per dog). Using only intracorporeal robotic surgery, a 2.5 cm enterotomy was made longitudinally in the small bowel, and then closed in a Heineke-Mikulicz configuration with a one-layer running 3-0 braided absorbable suture (strictureplasty). All animals were allowed to survive for 7 days with prospective monitoring of bowel movements, level of activity, oral intake, and abdominal examination. After 7 days, necropsy was performed, examining all strictureplasty sites for signs of sepsis. The endpoints of the study were recovery of normal intestinal function (bowel movements), intraoperative and postoperative complications, and the appearance of the anastomoses at necropsy. There was no intraoperative morbidity or mortality. All eight dogs survived 7 days and recovered well. All dogs had a bowel movement on the first postoperative day, and appeared healthy throughout the study period. Necropsy revealed that all 16 strictureplasty sites were healing without signs of sepsis. The median time per strictureplasty was 65 min (range, 45-110 min). One dog developed a superficial wound infection at a trocar site. A robotic surgical system can successfully be employed in the performance of intestinal strictureplasties in dogs. This study supports further investigation into the role of robotics in intestinal surgery in humans.

  3. Outcomes of robot-assisted simple enucleation of renal masses: A single European center experience.

    Science.gov (United States)

    Matei, Deliu Victor; Vartolomei, Mihai Dorin; Musi, Gennaro; Renne, Giuseppe; Tringali, Valeria Maria Lucia; Mistretta, Francesco Alessandro; Delor, Maurizio; Russo, Andrea; Cioffi, Antonio; Bianchi, Roberto; Cozzi, Gabriele; Di Trapani, Ettore; Bottero, Danilo; Cordima, Giovanni; Lucarelli, Giuseppe; Ferro, Matteo; de Cobelli, Ottavio

    2017-05-01

    The aim of this study was to assess the ability of pre-and intraoperative parameters, to predict the risk of perioperative complications after robot-assisted laparoscopic simple enucleation (RASE) of renal masses, and to evaluate the rate of trifecta achievement of this approach stratifying the cohort according to the use of ischemia during the enucleation.From April 2009 to June 2016, 129 patients underwent RASE at our Institution. We stratified the procedures in 2 groups: clamping and clamp-less RASE. After RASE, all specimens were retrospectively reviewed to assess the surface-intermediate-base (SIB) scoring system. Patients were followed-up according to the European Association of Urology guidelines recommendations. All pre-, intra-, and postoperative outcomes were prospectively collected in a customized database and retrospectively analyzed.A total of 112 (86.8%) patients underwent a pure RASE and 17 (13.2%) had a hybrid according to SIB classification system. The mean age was 61.17 years. In 21 patients (16.3%), complications occurred, 13 (61.9%) were Clavien 1 and 2, while 8 were Clavien 3a and b complications. Statistical significant association with complications was found in patients with American Society of Anestesiology (ASA) score 3 (44.5%, P = .04), longer mean operative time (OT) 195 versus 161.36 minutes (P =.03), mean postoperative hemoglobin (Hb) 10.1 versus 11.8 (P 3, longer OT, and ΔHb. RASE is suitable for the clamp-less approach, which allows to perform easier the pure enucleation (SIB 0) and to obtain higher rates of trifecta outcomes.

  4. Retention of fundamental surgical skills learned in robot-assisted surgery.

    Science.gov (United States)

    Suh, Irene H; Mukherjee, Mukul; Shah, Bhavin C; Oleynikov, Dmitry; Siu, Ka-Chun

    2012-12-01

    Evaluation of the learning curve for robotic surgery has shown reduced errors and decreased task completion and training times compared with regular laparoscopic surgery. However, most training evaluations of robotic surgery have only addressed short-term retention after the completion of training. Our goal was to investigate the amount of surgical skills retained after 3 months of training with the da Vinci™ Surgical System. Seven medical students without any surgical experience were recruited. Participants were trained with a 4-day training program of robotic surgical skills and underwent a series of retention tests at 1 day, 1 week, 1 month, and 3 months post-training. Data analysis included time to task completion, speed, distance traveled, and movement curvature by the instrument tip. Performance of the participants was graded using the modified Objective Structured Assessment of Technical Skills (OSATS) for robotic surgery. Participants filled out a survey after each training session by answering a set of questions. Time to task completion and the movement curvature was decreased from pre- to post-training and the performance was retained at all the corresponding retention periods: 1 day, 1 week, 1 month, and 3 months. The modified OSATS showed improvement from pre-test to post-test and this improvement was maintained during all the retention periods. Participants increased in self-confidence and mastery in performing robotic surgical tasks after training. Our novel comprehensive training program improved robot-assisted surgical performance and learning. All trainees retained their fundamental surgical skills for 3 months after receiving the training program.

  5. Preliminary experience in laparoscopic resection of hepatic hydatidectocyst with the Da Vinci Surgical System (DVSS): a case report.

    Science.gov (United States)

    Zou, Haibo; Luo, Lanyun; Xue, Hua; Wang, Guan; Wang, Xiankui; Luo, Le; Yao, Yutong; Xiang, Guangming; Huang, Xiaolun

    2017-09-11

    At present, Da Vinci robotic assisted hepatectomy has been routinely carried out in conditional units. But there is no report concerning the use of Da Vinci robots for hepatic hydatid cystectomy and experience on this aspect is seldom mentioned before. This study was to summarize the preliminary experience in laparoscopic resection of hepatic hydatidectocyst with the Da Vinci Surgical System (DVSS). A 29-year-old female diagnosed as hepatic hydatid in the right anterior lobe of liver was treated with laparoscopic resection by the DVSS under general anesthesia. Appropriate disposal of tumor cell in vascular system and disinfection of surgical field with hypertonic saline were conducted. The hepatic hydatidectocyst was resected completely with an operation time of 130 min, an intraoperative blood loss of 200 ml and a length of hospital stay for five days. The vital signs of patient were stable and no cyst fluid allergy occurred after operation. Our result showed that laparoscopic resection of hepatic hydatidectocyst by using the DVSS is safe and feasible on the basis of hospitals have rich experience in treatment of cystic echinococcosisliver, resection with DVSS and laparoscopic excision.

  6. The Impact of Laparoscopic Approaches on Short-term Outcomes in Patients Undergoing Liver Surgery for Metastatic Tumors.

    Science.gov (United States)

    Karagkounis, Georgios; Seicean, Andreea; Berber, Eren

    2015-06-01

    To compare the perioperative outcomes associated with open and laparoscopic (LAP) surgical approaches for liver metastases. The American College of Surgeons National Surgical Quality Improvement Program database was used to identify all adult patients who underwent surgical therapy for metastatic liver tumors between 2006 and 2012 (N=7684). Patients who underwent >1 procedure were excluded. Logistic regression after matching on propensity scores was used to assess the association between surgical approaches and perioperative outcomes. A total of 4555 patients underwent open resection, 387 LAP resection, 297 open radiofrequency ablation (RFA), and 265 LAP RFA. In propensity-matched samples (over 95% of patients successfully matched), there was no significant difference between LAP resection and LAP RFA in perioperative complications and length of stay and both compared favorably with their open counterparts. Minimally invasive approaches for secondary hepatic malignancies were associated with improved postoperative morbidity and length of stay and should be preferred in appropriate patients.

  7. Robot-assisted tubal reanastomosis: Initial experience in a single institution

    Directory of Open Access Journals (Sweden)

    Ahmet Göçmen

    2013-03-01

    Conclusion: Robot-assisted TLR is safe and feasible. This procedure may facilitate minimally invasive treatment for patients who want to regain their fertility without the aid of artificial reproductive techniques.

  8. ROBOT-ASSISTED SURGERY AND ROBOTS EXOSKELETONS FOR REHABILITATION: WORLD TECHNOLOGICAL LEADERS AND PERSPECTIVES OF RUSSIA

    Directory of Open Access Journals (Sweden)

    O. V. Cherchenko

    2015-01-01

    Full Text Available There was analysed the publication and patent activity with regard to two actively developing areas in the field of medical robototronics: robots-exoskeletons for rehabilitation of people with muscoloskeletal disorders and robot-assisted surgery. There was identified discrepancy in the structure of global and national publication and patent flows. There were revealed disadvantages of foreign innovations on robot-assisted surgery, which create prerequisites for promoting import-substituting innovations of domestic engineers. 

  9. Robot-Assisted Fracture Surgery: Surgical Requirements and System Design.

    Science.gov (United States)

    Georgilas, Ioannis; Dagnino, Giulio; Tarassoli, Payam; Atkins, Roger; Dogramadzi, Sanja

    2018-03-09

    The design of medical devices is a complex and crucial process to ensure patient safety. It has been shown that improperly designed devices lead to errors and associated accidents and costs. A key element for a successful design is incorporating the views of the primary and secondary stakeholders early in the development process. They provide insights into current practice and point out specific issues with the current processes and equipment in use. This work presents how information from a user-study conducted in the early stages of the RAFS (Robot Assisted Fracture Surgery) project informed the subsequent development and testing of the system. The user needs were captured using qualitative methods and converted to operational, functional, and non-functional requirements based on the methods derived from product design and development. This work presents how the requirements inform a new workflow for intra-articular joint fracture reduction using a robotic system. It is also shown how the various elements of the system are developed to explicitly address one or more of the requirements identified, and how intermediate verification tests are conducted to ensure conformity. Finally, a validation test in the form of a cadaveric trial confirms the ability of the designed system to satisfy the aims set by the original research question and the needs of the users.

  10. Robotic Assisted Transanal Polypectomies: Is There Any Indication?

    Science.gov (United States)

    Gómez Ruiz, Marcos; Cagigas Fernández, Carmen; Alonso Martín, Joaquín; Cristobal Poch, Lidia; Manuel Palazuelos, Carlos; Barredo Cañibano, Francisco Javier; Gómez Fleitas, Manuel; Castillo Diego, Julio

    2017-12-01

    Robotic assisted transanal polipectomy may have advantages compared with the conventional transanal minimally invasive surgery technique. We evaluate the safety, feasibility and advantages of this technique. Between February 2014 and October 2015, 9patients underwent robotic transanal polypectomy. We performed a retrospective study in which we analyse prospectively collected data regarding patient and tumor characteristics, perioperative outcomes, pathological report, morbidity and mortality. A total of 5 male and 4 female patients underwent robotic TAMIS. Lesions were 6,22cm from the anal verge. Mean size was 15,8cm 2 . All procedures were performed in the lithotomy position. Closure of the defect was performed in all cases. Mean blood loss was 39,8ml. Mean operative time was 71,9min. No severe postoperative complications or readmissions occured. Median hospital stay was 2,5 days. Robotic TAMIS is useful to treat complex rectal lesions. Our transanal platform allowed a wider range of movements of the robotic arms and to perform all procedures in the lithotomy position. Copyright © 2017 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  11. Automated robot-assisted surgical skill evaluation: Predictive analytics approach.

    Science.gov (United States)

    Fard, Mahtab J; Ameri, Sattar; Darin Ellis, R; Chinnam, Ratna B; Pandya, Abhilash K; Klein, Michael D

    2018-02-01

    Surgical skill assessment has predominantly been a subjective task. Recently, technological advances such as robot-assisted surgery have created great opportunities for objective surgical evaluation. In this paper, we introduce a predictive framework for objective skill assessment based on movement trajectory data. Our aim is to build a classification framework to automatically evaluate the performance of surgeons with different levels of expertise. Eight global movement features are extracted from movement trajectory data captured by a da Vinci robot for surgeons with two levels of expertise - novice and expert. Three classification methods - k-nearest neighbours, logistic regression and support vector machines - are applied. The result shows that the proposed framework can classify surgeons' expertise as novice or expert with an accuracy of 82.3% for knot tying and 89.9% for a suturing task. This study demonstrates and evaluates the ability of machine learning methods to automatically classify expert and novice surgeons using global movement features. Copyright © 2017 John Wiley & Sons, Ltd.

  12. Robot-Assisted Free Flap in Head and Neck Reconstruction

    Directory of Open Access Journals (Sweden)

    Han Gyeol Song

    2013-07-01

    Full Text Available Background  Robots have allowed head and neck surgeons to extirpate oropharyngealtumors safely without the need for lip-split incision or mandibulotomy. Using robots inoropharyngealreconstruction is newbut essentialfor oropharyngeal defectsthatresultfromrobotic tumor excision. We report our experience with robotic free-flap reconstruction ofhead and neck defectsto exemplify the necessity forrobotic reconstruction.Methods  We investigated head and neck cancer patients who underwent ablation surgeryand free-flap reconstruction by robot. Between July 1, 2011 andMarch 31, 2012, 5 caseswereperformed and patient demographics, location of tumor, pathologic stage, reconstructionmethods, flap size, recipient vessel, necessary pedicle length, and operation time wereinvestigated.Results  Among five free-flap reconstructions, four were radial forearm free flaps and onewas an anterolateral thigh free-flap. Four flaps used the superior thyroid artery and oneflap used a facial artery as the recipient vessel. The average pedicle length was 8.8 cm. Flapinsetting and microanastomosis were achieved using a specially manufactured roboticinstrument. The total operation timewas 1,041.0 minutes(range, 814 to 1,132 minutes, andcomplicationsincluding flap necrosis, hematoma, andwound dehiscence did not occur.Conclusions  Thisstudy demonstratesthe clinically applicable use ofrobotsin oropharyngealreconstruction, especially using a free flap. A robot can assist the operator in insettingthe flap at a deep portion of the oropharynx without the need to perform a traditionalmandibulotomy. Robot-assisted reconstruction may substitute for existing surgical methodsand is accepted asthemost up-to-datemethod.

  13. Robot-assisted urologic surgery in 2010 - Advancements and future outlook

    Directory of Open Access Journals (Sweden)

    Paurush Babbar

    2011-01-01

    Full Text Available Robotic surgery is a cutting edge and minimally invasive procedure, which has generated a great deal of excitement in the urologic community. While there has been much advancement in this emerging technology, it is safe to say that robotic urologic surgery holds tremendous potential for progress in the near future. Hence, it is paramount that urologists stay up-to-date regarding new developments in the realm of robotics with respect to novel applications, limitations and opportunities for incorporation into their practice. Robot-assisted surgery provides an enhanced 3D view, increased magnification of the surgical field, better manual dexterity, relatively bloodless field, elimination of surgeon′s tremor, reduction in a surgeon′s fatigue and mitigation of scattered light. All these factors translate into greater precision of surgical dissection, which is imperative in providing better intraoperative and postoperative outcomes. Pioneering work assessing the feasibility of robotic surgery in urology began in the early 2000′s with robot-assisted radical prostatectomy and has since expanded to procedures such as robot-assisted radical cystectomy, robot-assisted partial nephrectomy, robot-assisted nephroureterectomy and robot-assisted pyeloplasty. A MEDLINE search was used to identify recent articles (within the last two years and publications of specific importance, which highlighted the recent developments and future direction of robotics. This review will use the aforementioned urologic surgeries as vehicles to evaluate the current status and future role of robotics in the advancement of the field of urology.

  14. Pure Laparoscopic Versus Open Liver Resection for Primary Liver Carcinoma in Elderly Patients: A Single-Center, Case-Matched Study.

    Science.gov (United States)

    Wang, Xi-Tao; Wang, Hong-Guang; Duan, Wei-Dong; Wu, Cong-Ying; Chen, Ming-Yi; Li, Hao; Huang, Xin; Zhang, Fu-Bo; Dong, Jia-Hong

    2015-10-01

    Pure laparoscopic liver resection (PLLR) has been reported to be as safe and effective as open liver resection (OLR) for liver lesions, and it is associated with less intraoperative blood loss, shorter hospital stay, and lower complication rate. However, studies comparing PLLR with OLR in elderly patients were limited. The aim of this study was to analyze the short-term outcome of PLLR versus OLR for primary liver carcinoma (PLC) in elderly patients.Between January 2008 and October 2014, 30 consecutive elderly patients (≥70 years) who underwent PLLR for PLC were included into analysis. Sixty patients who received OLR for PLC during the same study period were also included as a case-matched control group. Patients were well matched in terms of age, sex, comorbid illness, Child Pugh class, American Society of Anesthesiologists grade, tumor size, tumor location, and extent of hepatectomy.No significant differences were observed with regard to patient preoperative baseline status, median tumor size (Group PLLR 4.0 cm vs Group OLR 5.0 cm, P = 0.125), tumor location, extent of hepatectomy, and operation time (Group PLLR 133 minutes vs Group OLR 170 minutes, P = 0.073). Compared with OLR, the PLLR group displayed a significantly less frequent Pringle maneuver application (10.0% vs 70.0%, P PLC is as safe and feasible as OLR, but with less blood loss, shorter hospital stay, and lower hospitalization cost for selected elderly patients.

  15. Robot-assisted pancreatoduodenectomy with preservation of the vascular supply for autologous islet cell isolation and transplantation: a case report

    Directory of Open Access Journals (Sweden)

    Giulianotti Piero

    2012-03-01

    Full Text Available Abstract Introduction For patients with chronic pancreatitis presenting with medically intractable abdominal pain, surgical intervention may be the only treatment option. However, extensive pancreatic resections are typically performed open and are associated with a substantial amount of postoperative pain, wound complications and long recovery time. Minimally invasive surgery offers an avenue to improve results; however, current limitations of laparoscopic surgery render its application in the setting of chronic pancreatitis technically demanding. Additionally, pancreatic resections are associated with a high incidence of diabetes. Transplantation of islets isolated from the resected pancreas portion offers a way to prevent post-surgical diabetes; however, preservation of the vascular supply during pancreatic resection, which determines islet cell viability, is technically difficult using current laparoscopic approaches. With recent advances in the surgical field, robotic surgery now provides a means to overcome these obstacles to achieve the end goals of pain relief and preserved endocrine function. We present the first report of a novel, minimally invasive robotic approach for resection of the pancreatic head that preserves vascular supply and enables the isolation of a high yield of viable islets for transplantation. Case presentation A 35-year old Caucasian woman presented with intractable chronic abdominal pain secondary to chronic pancreatitis, with a stricture of her main pancreatic duct at the level of the ampulla of Vater and distal dilatation. She was offered a robotic-assisted pylorus-preserving pancreatoduodenectomy and subsequent islet transplantation, to both provide pain relief and preserve insulin-secretory reserves. Conclusion We present a novel, minimally invasive robotic approach for resection of the pancreatic head with complete preservation of the vascular supply, minimal warm ischemia time (less than three minutes and

  16. The immediate effects of robot-assistance on energy consumption and cardiorespiratory load during walking compared to walking without robot-assistance: a systematic review.

    Science.gov (United States)

    Lefeber, Nina; Swinnen, Eva; Kerckhofs, Eric

    2017-10-01

    The integration of sufficient cardiovascular stress into robot-assisted gait (RAG) training could combine the benefits of both RAG and aerobic training. The aim was to summarize literature data on the immediate effects of RAG compared to walking without robot-assistance on metabolic-, cardiorespiratory- and fatigue-related parameters. PubMed and Web of Science were searched for eligible articles till February 2016. Means, SDs and significance values were extracted. Effect sizes were calculated. Fourteen studies were included, concerning 155 participants (85 healthy subjects, 39 stroke and 31 spinal cord injury patients), 9 robots (2 end-effectors, 1 treadmill-based and 6 wearable exoskeletons), and 7 outcome parameters (mostly oxygen consumption and heart rate). Overall, metabolic and cardiorespiratory parameters were lower during RAG compared to walking without robot-assistance (moderate to large effect sizes). In healthy subjects, when no body-weight support (BWS) was provided, RAG with an end-effector device was more energy demanding than walking overground (p > .05, large effect sizes). Generally, results suggest that RAG is less energy-consuming and cardiorespiratory stressful than walking without robot-assistance, but results depend on factors such as robot type, walking speed, BWS and effort. Additional research is needed to draw firm conclusions. Implications for Rehabilitation Awareness of the energy consumption and cardiorespiratory load of robot-assisted gait (RAG) training is important in the rehabilitation of (neurological) patients with impaired cardiorespiratory fitness and patients who are at risk of cardiovascular diseases. On the other hand, the integration of sufficient cardiometabolic stress in RAG training could combine the effects of both RAG and aerobic training. Energy consumption and cardiorespiratory load during walking with robot-assistance seems to depend on factors such as robot type, walking speed, body-weight support or amount of

  17. Robot-assisted partial nephrectomy for hilar tumors: perioperative outcomes.

    Science.gov (United States)

    Eyraud, Rémi; Long, Jean-Alexandre; Snow-Lisy, Devon; Autorino, Riccardo; Hillyer, Shahab; Klink, Joseph; Rizkala, Emad; Stein, Robert J; Kaouk, Jihad H; Haber, Georges-Pascal

    2013-06-01

    To compare perioperative outcomes of robot-assisted partial nephrectomy (RAPN) for hilar vs nonhilar tumors. The study retrospectively reviewed 364 patients with available computed tomography scans undergoing RAPN. Demographic data and perioperative outcomes results were compared between the hilar (group 1, n = 70) and nonhilar tumors (group 2, n = 294). Multivariate analysis was used to identify predictors of warm ischemia time (WIT), estimated blood loss (EBL), major perioperative complications, and postoperative renal function. There were no differences with respect to demographic variables. Hilar tumors had higher RENAL (radius, exophytic/endophytic properties of the tumor, nearness of tumor deepest portion to the collecting system or sinus, anterior/posterior descriptor and the location relative to polar lines) scores (P hilar tumors were associated with greater operative time (210 vs 180 minutes, P hilar vs nonhilar patients on postoperative day 3 (70.12 vs 74.71 mL/min/1.73 m(2), P = .31) or at last follow-up (72.62 vs 75.78 mL/min/1.73 m(2), P = .40), respectively. Multivariate analysis found hilar location was independently associated with increased WIT without significant changes in EBL, major complications, or postoperative renal function. RAPN represents a safe and effective procedure for hilar tumors. Hilar location for patients undergoing RAPN in a high-volume institution seems not be associated with an increased risk of transfusions, major complications, or decline of early postoperative renal function. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. Understanding Cognitive Performance During Robot-Assisted Surgery.

    Science.gov (United States)

    Guru, Khurshid A; Shafiei, Somayeh B; Khan, Atif; Hussein, Ahmed A; Sharif, Mohamed; Esfahani, Ehsan T

    2015-10-01

    To understand cognitive function of an expert surgeon in various surgical scenarios while performing robot-assisted surgery. In an Internal Review Board approved study, National Aeronautics and Space Administration-Task Load Index (NASA-TLX) questionnaire with surgical field notes were simultaneously completed. A wireless electroencephalography (EEG) headset was used to monitor brain activity during all procedures. Three key portions were evaluated: lysis of adhesions, extended lymph node dissection, and urethro-vesical anastomosis (UVA). Cognitive metrics extracted were distraction, mental workload, and mental state. In evaluating lysis of adhesions, mental state (EEG) was associated with better performance (NASA-TLX). Utilizing more mental resources resulted in better performance as self-reported. Outcomes of lysis were highly dependent on cognitive function and decision-making skills. In evaluating extended lymph node dissection, there was a negative correlation between distraction level (EEG) and mental demand, physical demand and effort (NASA-TLX). Similar to lysis of adhesion, utilizing more mental resources resulted in better performance (NASA-TLX). Lastly, with UVA, workload (EEG) negatively correlated with mental and temporal demand and was associated with better performance (NASA-TLX). The EEG recorded workload as seen here was a combination of both cognitive performance (finding solution) and motor workload (execution). Majority of workload was contributed by motor workload of an expert surgeon. During UVA, muscle memory and motor skills of expert are keys to completing the UVA. Cognitive analysis shows that expert surgeons utilized different mental resources based on their need. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Controlling patient participation during robot-assisted gait training

    Science.gov (United States)

    2011-01-01

    Background The overall goal of this paper was to investigate approaches to controlling active participation in stroke patients during robot-assisted gait therapy. Although active physical participation during gait rehabilitation after stroke was shown to improve therapy outcome, some patients can behave passively during rehabilitation, not maximally benefiting from the gait training. Up to now, there has not been an effective method for forcing patient activity to the desired level that would most benefit stroke patients with a broad variety of cognitive and biomechanical impairments. Methods Patient activity was quantified in two ways: by heart rate (HR), a physiological parameter that reflected physical effort during body weight supported treadmill training, and by a weighted sum of the interaction torques (WIT) between robot and patient, recorded from hip and knee joints of both legs. We recorded data in three experiments, each with five stroke patients, and controlled HR and WIT to a desired temporal profile. Depending on the patient's cognitive capabilities, two different approaches were taken: either by allowing voluntary patient effort via visual instructions or by forcing the patient to vary physical effort by adapting the treadmill speed. Results We successfully controlled patient activity quantified by WIT and by HR to a desired level. The setup was thereby individually adaptable to the specific cognitive and biomechanical needs of each patient. Conclusion Based on the three successful approaches to controlling patient participation, we propose a metric which enables clinicians to select the best strategy for each patient, according to the patient's physical and cognitive capabilities. Our framework will enable therapists to challenge the patient to more activity by automatically controlling the patient effort to a desired level. We expect that the increase in activity will lead to improved rehabilitation outcome. PMID:21429200

  20. Robot Assisted Surgical Ward Rounds: Virtually Always There

    Directory of Open Access Journals (Sweden)

    Stefanie M. Croghan

    2018-05-01

    Full Text Available Background:  While an explosion in technological sophistication has revolutionized surgery within the operating theatre, delivery of surgical ward-based care has seen little innovation.  Use of telepresence allowing off-site clinicians communicate with patients has been largely restricted to outpatient settings or use of complex, expensive, static devices.  We designed a prospective study to ascertain feasibility and face validity of a remotely controlled mobile audiovisual drone (LUCY to access inpatients.  This device is, uniquely, lightweight, freely mobile and emulates ‘human’ interaction by swiveling and adjusting height to patients’ eye-level.     Methods: Robot-assisted ward rounds(RASWR were conducted over 3 months. A remotely located consultant surgeon communicated with patients/bedside teams via encrypted audiovisual telepresence robot (DoubleRoboticstm, California USA.  Likert-scale satisfaction questionnaires, incorporating free-text sections for mixed-methods data collection, were disseminated to patient and staff volunteers following RASWRs.  The same cohort completed a linked questionnaire following conventional (gold-standard rounds, acting as control group. Data were paired, and non-parametric analysis performed.     Results: RASWRs are feasible (>90% completed without technical difficulty. The RASWR(n=52 observations demonstrated face validity with strong correlations (r>0.7; Spearman, p-value <0.05 between robotic and conventional ward rounds among patients and staff on core themes, including dignity/confidentiality/communication/satisfaction with management plan. Patients (96.08%, n=25 agreed RASWR were a satisfactory alternative when consultant physical presence was not possible. There was acceptance of nursing/NCHD cohort (100% (n=11 willing to regularly partake in RASWR.    Conclusion: RASWRs receive high levels of patient and staff acceptance, and offer a valid alternative to conventional ward rounds

  1. Robot-Assisted Free Flap in Head and Neck Reconstruction

    Directory of Open Access Journals (Sweden)

    Han Gyeol Song

    2013-07-01

    Full Text Available BackgroundRobots have allowed head and neck surgeons to extirpate oropharyngeal tumors safely without the need for lip-split incision or mandibulotomy. Using robots in oropharyngeal reconstruction is new but essential for oropharyngeal defects that result from robotic tumor excision. We report our experience with robotic free-flap reconstruction of head and neck defects to exemplify the necessity for robotic reconstruction.MethodsWe investigated head and neck cancer patients who underwent ablation surgery and free-flap reconstruction by robot. Between July 1, 2011 and March 31, 2012, 5 cases were performed and patient demographics, location of tumor, pathologic stage, reconstruction methods, flap size, recipient vessel, necessary pedicle length, and operation time were investigated.ResultsAmong five free-flap reconstructions, four were radial forearm free flaps and one was an anterolateral thigh free-flap. Four flaps used the superior thyroid artery and one flap used a facial artery as the recipient vessel. The average pedicle length was 8.8 cm. Flap insetting and microanastomosis were achieved using a specially manufactured robotic instrument. The total operation time was 1,041.0 minutes (range, 814 to 1,132 minutes, and complications including flap necrosis, hematoma, and wound dehiscence did not occur.ConclusionsThis study demonstrates the clinically applicable use of robots in oropharyngeal reconstruction, especially using a free flap. A robot can assist the operator in insetting the flap at a deep portion of the oropharynx without the need to perform a traditional mandibulotomy. Robot-assisted reconstruction may substitute for existing surgical methods and is accepted as the most up-to-date method.

  2. Robot Assisted Surgical Ward Rounds: Virtually Always There.

    Science.gov (United States)

    Croghan, Stefanie M; Carroll, Paul; Reade, Sarah; Gillis, Amy E; Ridgway, Paul F

    2018-05-02

     While an explosion in technological sophistication has revolutionized surgery within the operating theatre, delivery of surgical ward-based care has seen little innovation.  Use of telepresence allowing off-site clinicians communicate with patients has been largely restricted to outpatient settings or use of complex, expensive, static devices.  We designed a prospective study to ascertain feasibility and face validity of a remotely controlled mobile audiovisual drone (LUCY) to access inpatients.  This device is, uniquely, lightweight, freely mobile and emulates 'human' interaction by swiveling and adjusting height to patients' eye-level.   METHODS: Robot-assisted ward rounds(RASWR) were conducted over 3 months. A remotely located consultant surgeon communicated with patients/bedside teams via encrypted audiovisual telepresence robot (DoubleRoboticstm, California USA).  Likert-scale satisfaction questionnaires, incorporating free-text sections for mixed-methods data collection, were disseminated to patient and staff volunteers following RASWRs.  The same cohort completed a linked questionnaire following conventional (gold-standard) rounds, acting as control group. Data were paired, and non-parametric analysis performed.  RESULTS: RASWRs are feasible (>90% completed without technical difficulty). The RASWR(n=52 observations) demonstrated face validity with strong correlations (r>0.7; Spearman, p-value <0.05) between robotic and conventional ward rounds among patients and staff on core themes, including dignity/confidentiality/communication/satisfaction with management plan. Patients (96.08%, n=25) agreed RASWR were a satisfactory alternative when consultant physical presence was not possible. There was acceptance of nursing/NCHD cohort (100% (n=11) willing to regularly partake in RASWR).  CONCLUSION: RASWRs receive high levels of patient and staff acceptance, and offer a valid alternative to conventional ward rounds when a consultant cannot be

  3. Multimodal hybrid imaging agents for sentinel node mapping as a means to (re)connect nuclear medicine to advances made in robot-assisted surgery.

    Science.gov (United States)

    KleinJan, Gijs H; van den Berg, Nynke S; de Jong, Jeroen; Wit, Esther M; Thygessen, Helene; Vegt, Erik; van der Poel, Henk G; van Leeuwen, Fijs W B

    2016-07-01

    Radical prostatectomy and complementary extended pelvic lymph node dissection (ePLND) of sentinel lymph nodes (SNs) and non-sentinel lymph nodes (LNs) at risk of containing metastases are increasingly being performed using high-tech robot-assisted approaches. Although this technological evolution has clear advantages, the physical nature of robotic systems limits the integrated use of routine radioguided surgery technologies. Hence, engineering effort in robotics are focused on the integration of fluorescence guidance technologies. Using the hybrid SN tracer indocyanine green-(99m)Tc-nanocolloid (radioactive and fluorescent), for the first time in combination with a robot-integrated laparoscope, we investigated whether the robot-assisted approach affects the accuracy of fluorescence detection of SNs identified preoperatively using nuclear medicine. The study included 55 patients (Briganti nomogram-based risk >5 % on LN metastases) scheduled for robot-assisted radical prostatectomy, SN biopsy and ePLND. Following indocyanine green-(99m)Tc-nanocolloid injection, preoperative nuclear imaging (lymphoscintigraphy and SPECT/CT) was used to locate the SN(s). The fluorescence laparoscope was used intraoperatively to identify the SN(s) with standard fluorescence settings (in 50 patients) and with customized settings (in 5 patients). The number and location of the SNs, the radioactive, fluorescence (both in vivo and ex vivo) and tumour status of the resected SNs/LNs, and postoperative complications were recorded and analysed. Combined, preoperative lymphoscintigraphy and SPECT/CT imaging identified 212 SNs (median 4 per patient). Intraoperative fluorescence imaging using standard fluorescence settings visualized 80.4 % (148/184 SNs; 50 patients; ex vivo 97.8 %). This increased to 85.7 % (12/14 SNs; 5 patients; ex vivo 100 %) with customized fluorescence settings. SPECT/CT images provided guidance towards the residual SNs. Ex vivo all removed SNs were radioactive. SNs

  4. Multimodal hybrid imaging agents for sentinel node mapping as a means to (re)connect nuclear medicine to advances made in robot-assisted surgery

    Energy Technology Data Exchange (ETDEWEB)

    KleinJan, Gijs H. [Leiden University Medical Hospital, Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden (Netherlands); The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Nuclear Medicine, Amsterdam (Netherlands); Berg, Nynke S. van den [Leiden University Medical Hospital, Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden (Netherlands); The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Urology, Amsterdam (Netherlands); Jong, Jeroen de [The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Pathology, Amsterdam (Netherlands); Wit, Esther M.; Poel, Henk G. van der [The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Urology, Amsterdam (Netherlands); Thygessen, Helene [The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Biostatistics, Amsterdam (Netherlands); Vegt, Erik [The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Nuclear Medicine, Amsterdam (Netherlands); Leeuwen, Fijs W.B. van [Leiden University Medical Hospital, Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden (Netherlands); The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Urology, Amsterdam (Netherlands); The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Head and Neck Surgery and Oncology, Amsterdam (Netherlands)

    2016-07-15

    Radical prostatectomy and complementary extended pelvic lymph node dissection (ePLND) of sentinel lymph nodes (SNs) and non-sentinel lymph nodes (LNs) at risk of containing metastases are increasingly being performed using high-tech robot-assisted approaches. Although this technological evolution has clear advantages, the physical nature of robotic systems limits the integrated use of routine radioguided surgery technologies. Hence, engineering effort in robotics are focused on the integration of fluorescence guidance technologies. Using the hybrid SN tracer indocyanine green-{sup 99m}Tc-nanocolloid (radioactive and fluorescent), for the first time in combination with a robot-integrated laparoscope, we investigated whether the robot-assisted approach affects the accuracy of fluorescence detection of SNs identified preoperatively using nuclear medicine. The study included 55 patients (Briganti nomogram-based risk >5 % on LN metastases) scheduled for robot-assisted radical prostatectomy, SN biopsy and ePLND. Following indocyanine green-{sup 99m}Tc-nanocolloid injection, preoperative nuclear imaging (lymphoscintigraphy and SPECT/CT) was used to locate the SN(s). The fluorescence laparoscope was used intraoperatively to identify the SN(s) with standard fluorescence settings (in 50 patients) and with customized settings (in 5 patients). The number and location of the SNs, the radioactive, fluorescence (both in vivo and ex vivo) and tumour status of the resected SNs/LNs, and postoperative complications were recorded and analysed. Combined, preoperative lymphoscintigraphy and SPECT/CT imaging identified 212 SNs (median 4 per patient). Intraoperative fluorescence imaging using standard fluorescence settings visualized 80.4 % (148/184 SNs; 50 patients; ex vivo 97.8 %). This increased to 85.7 % (12/14 SNs; 5 patients; ex vivo 100 %) with customized fluorescence settings. SPECT/CT images provided guidance towards the residual SNs. Ex vivo all removed SNs were radioactive. SNs

  5. Multimodal hybrid imaging agents for sentinel node mapping as a means to (re)connect nuclear medicine to advances made in robot-assisted surgery

    International Nuclear Information System (INIS)

    KleinJan, Gijs H.; Berg, Nynke S. van den; Jong, Jeroen de; Wit, Esther M.; Poel, Henk G. van der; Thygessen, Helene; Vegt, Erik; Leeuwen, Fijs W.B. van

    2016-01-01

    Radical prostatectomy and complementary extended pelvic lymph node dissection (ePLND) of sentinel lymph nodes (SNs) and non-sentinel lymph nodes (LNs) at risk of containing metastases are increasingly being performed using high-tech robot-assisted approaches. Although this technological evolution has clear advantages, the physical nature of robotic systems limits the integrated use of routine radioguided surgery technologies. Hence, engineering effort in robotics are focused on the integration of fluorescence guidance technologies. Using the hybrid SN tracer indocyanine green- 99m Tc-nanocolloid (radioactive and fluorescent), for the first time in combination with a robot-integrated laparoscope, we investigated whether the robot-assisted approach affects the accuracy of fluorescence detection of SNs identified preoperatively using nuclear medicine. The study included 55 patients (Briganti nomogram-based risk >5 % on LN metastases) scheduled for robot-assisted radical prostatectomy, SN biopsy and ePLND. Following indocyanine green- 99m Tc-nanocolloid injection, preoperative nuclear imaging (lymphoscintigraphy and SPECT/CT) was used to locate the SN(s). The fluorescence laparoscope was used intraoperatively to identify the SN(s) with standard fluorescence settings (in 50 patients) and with customized settings (in 5 patients). The number and location of the SNs, the radioactive, fluorescence (both in vivo and ex vivo) and tumour status of the resected SNs/LNs, and postoperative complications were recorded and analysed. Combined, preoperative lymphoscintigraphy and SPECT/CT imaging identified 212 SNs (median 4 per patient). Intraoperative fluorescence imaging using standard fluorescence settings visualized 80.4 % (148/184 SNs; 50 patients; ex vivo 97.8 %). This increased to 85.7 % (12/14 SNs; 5 patients; ex vivo 100 %) with customized fluorescence settings. SPECT/CT images provided guidance towards the residual SNs. Ex vivo all removed SNs were radioactive. SNs were

  6. Incorporating robotic-assisted surgery for endometrial cancer staging: Analysis of morbidity and costs.

    Science.gov (United States)

    Bogani, Giorgio; Multinu, Francesco; Dowdy, Sean C; Cliby, William A; Wilson, Timothy O; Gostout, Bobbie S; Weaver, Amy L; Borah, Bijan J; Killian, Jill M; Bijlani, Akash; Angioni, Stefano; Mariani, Andrea

    2016-05-01

    To evaluate how the introduction of robotic-assisted surgery affects treatment-related morbidity and cost of endometrial cancer (EC) staging. We retrospectively reviewed the records of consecutive patients with stage I-III EC undergoing surgical staging between 2007 and 2012 at our institution. Costs (from surgery to 30days after surgery) were set based on the Medicare cost-to-charge ratio for each year and inflated to 2014 values. Inverse probability weighting (IPW) was used to decrease the allocation bias when comparing outcomes between surgical groups. We focused our analysis on the 251 EC patients who had robotic-assisted surgery and the 384 who had open staging. During the study period, the use of robotic-assisted surgery increased and open staging decreased (P<0.001). Correcting group imbalances by using IPW methodology, we observed that patients undergoing robotic-assisted staging had a significantly lower postoperative complication rate, lower blood transfusion rate, longer median operating time, shorter median length of stay, and lower readmission rate than patients undergoing open staging (all P<0.001). Overall 30-day costs were similar between the 2 groups, with robotic-assisted surgery having significantly higher median operating room costs ($2820 difference; P<0.001) but lower median room and board costs ($2929 difference; P<0.001) than open surgery. Increasing experience with robotic-assisted staging was significantly associated with a decrease in median operating time (P=0.002) and length of stay (P=0.003). The implementation of robotic-assisted surgery for EC staging improves patient outcomes. It provides women the benefits of minimally invasive surgery without increasing costs and potentially improves patient turnover. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Robot-Assisted Training for People With Spinal Cord Injury: A Meta-Analysis.

    Science.gov (United States)

    Cheung, Eddy Y Y; Ng, Thomas K W; Yu, Kevin K K; Kwan, Rachel L C; Cheing, Gladys L Y

    2017-11-01

    To investigate the effects of robot-assisted training on the recovery of people with spinal cord injury (SCI). Randomized controlled trials (RCTs) or quasi-RCTs involving people with SCI that compared robot-assisted upper limbs or lower limbs training with a control of other treatment approach or no treatment. We included studies involving people with complete or incomplete SCIs. We searched MEDLINE, CINAHL, Cochrane Central Register of Controlled Trials (Cochrane Library), and Embase to August 2016. Bibliographies of relevant articles on the effect of body-weight-supported treadmill training on subjects with SCI were screened to avoid missing relevant articles from the search of databases. All kinds of objective assessments concerning physical ability, mobility, and/or functional ability were included. Assessments could be clinical tests (ie, 6-minute walk test, FIM) or laboratory tests (ie, gait analysis). Subjective outcome measures were excluded from this review. Eleven RCT studies involving 443 subjects were included in the study. Meta-analysis was performed on the included studies. Walking independence (3.73; 95% confidence interval [CI], -4.92 to -2.53; P<.00001; I 2 =38%) and endurance (53.32m; 95% CI, -73.15 to -33.48; P<.00001; I 2 =0%) were found to have better improvement in robot-assisted training groups. Lower limb robot-assisted training was also found to be as effective as other types of body-weight-supported training. There is a lack of upper limb robot-assisted training studies; therefore, performing a meta-analysis was not possible. Robot-assisted training is an adjunct therapy for physical and functional recovery for patients with SCI. Future high-quality studies are warranted to investigate the effects of robot-assisted training on functional and cardiopulmonary recovery of patients with SCI. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  8. Walking with robot assistance: the influence of body weight support on the trunk and pelvis kinematics.

    Science.gov (United States)

    Swinnen, Eva; Baeyens, Jean-Pierre; Knaepen, Kristel; Michielsen, Marc; Hens, Gerrit; Clijsen, Ron; Goossens, Maggie; Buyl, Ronald; Meeusen, Romain; Kerckhofs, Eric

    2015-05-01

    The goal was to assess in healthy participants the three-dimensional kinematics of the pelvis and the trunk during robot-assisted treadmill walking (RATW) at 0%, 30% and 50% body weight support (BWS), compared with treadmill walking (TW). 18 healthy participants walked (2 kmph) on a treadmill with and without robot assistance (Lokomat; 60% guidance force; 0%, 30% and 50% BWS). After an acclimatisation period (four minutes), trunk and pelvis kinematics were registered in each condition (Polhemus Liberty [240 Hz]). The results were analysed using a repeated measures analysis of variance with Bonferroni correction, with the level of suspension as within-subject factor. During RATW with BWS, there were significantly (1) smaller antero-posterior and lateral translations of the trunk and the pelvis; (2) smaller antero-posterior flexion and axial rotation of the trunk; (3) larger lateral flexion of the trunk; and (4) larger antero-posterior tilting of the pelvis compared with TW. There are significant differences in trunk and pelvis kinematics in healthy persons during TW with and without robot assistance. These data are relevant in gait rehabilitation, relating to normal balance regulation. Additional research is recommended to further assess the influence of robot assistance on human gait. The trunk and pelvis moves in a different way during walking with robot assistance. The data suggest that the change in movement is due to the robot device and the harness of the suspension system more than due to the level of suspension itself.

  9. Da Vinci robot-assisted system for thymectomy: experience of 55 patients in China.

    Science.gov (United States)

    Jun, Yi; Hao, Li; Demin, Li; Guohua, Dong; Hua, Jing; Yi, Shen

    2014-09-01

    Da Vinci robot-assisted thymectomy has been used in the past several years in China, however, practical experience in performing this approach in China remains limited. Thus, the study aimed to evaluate the experience of da Vinci robot-assisted thymectomy in China. From June 2010 to December 2012, 55 patients with diseases of the thymus underwent thymectomy using the da Vinci surgical HD robotic system. The clinical data of the da Vinci robot-assisted thymectomies were compared with the data of video-assisted thoracoscopic thymectomies in the same period. All da Vinci robot operations were successful. This is a retrospective analysis which demonstrated that compared with video-assisted thoracoscopic thymectomy in the same period, the clinical outcomes of da Vinci robot-assisted thymectomy were not significantly different. The da Vinci robot-assisted thymectomy is a safe, minimally invasive, and convenient operation, and shows promise for general thoracic surgery in China. Copyright © 2014 John Wiley & Sons, Ltd.

  10. Pancreatic fistula after laparoscopic splenectomy in patients with hypersplenism due to liver cirrhosis: effect of fibrin glue and polyglycolic acid felt on prophylaxis of postoperative complications.

    Science.gov (United States)

    Tsutsumi, Norifumi; Tomikawa, Morimasa; Akahoshi, Tomohiko; Kawanaka, Hirofumi; Ota, Mitsuhiko; Sakaguchi, Yoshihisa; Kusumoto, Tetsuya; Ikejiri, Koji; Hashizume, Makoto; Maehara, Yoshihiko

    2016-11-01

    This study aimed to determine the effect of fibrin glue and polyglycolic acid (PGA) felt on prevention of pancreatic fistula (PF) after laparoscopic splenectomy in patients with hypersplenism due to liver cirrhosis. Fifty consecutive patients were enrolled in this prospective study. Twenty-three patients underwent laparoscopic splenectomy with a fibrin sheet (fibrin sheet group). The sealing ability of each treatment was evaluated by an ex vivo pressure test model. Based on the results from ex vivo experiments, 27 patients received prophylaxis using fibrin glue and PGA felt (PGA with fibrin group). The primary endpoint was the incidence of PF. Significantly more (5, 22%) patients developed PF in the fibrin sheet group than in the PGA with fibrin group (0%, P = .037). Our new application of fibrin glue and PGA felt is an effective prophylactic procedure for preventing development of PF after laparoscopic splenectomy. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Cost-Benefit Performance Simulation of Robot-Assisted Thoracic Surgery As Required for Financial Viability under the 2016 Revised Reimbursement Paradigm of the Japanese National Health Insurance System.

    Science.gov (United States)

    Kajiwara, Naohiro; Kato, Yasufumi; Hagiwara, Masaru; Kakihana, Masatoshi; Ohira, Tatsuo; Kawate, Norihiko; Ikeda, Norihiko

    2018-04-20

    To discuss the cost-benefit performance (CBP) and establish a medical fee system for robotic-assisted thoracic surgery (RATS) under the Japanese National Health Insurance System (JNHIS), which is a system not yet firmly established. All management steps for RATS are identical, such as preoperative and postoperative management. This study examines the CBP based on medical fees of RATS under the JNHIS introduced in 2016. Robotic-assisted laparoscopic prostatectomy (RALP) and robotic-assisted partial nephrectomy (RAPN) now receive insurance reimbursement under the category of use of support devices for endoscopic surgery ($5420 and $3485, respectively). If the same standard amount were to be applied to RATS, institutions would need to perform at least 150 or 300 procedures thoracic operation per year to show a positive CBP ($317 per procedure as same of RALP and $130 per procedure as same of RAPN, respectively). Robotic surgery in some areas receives insurance reimbursement for its "supportive" use for endoscopic surgery as for RALP and RAPN. However, at present, it is necessary to perform da Vinci Surgical System Si (dVSi) surgery at least 150-300 times in a year in a given institution to prevent a deficit in income.

  12. Combined Oocyte Retrieval and Robot-assisted Hysterectomy in a Super Morbidly Obese Patient with Endometrial Carcinoma.

    Science.gov (United States)

    Chung, Esther H; Brady, Paula C; Smith, Kimberly Keefe; Davis, Michelle R; Muto, Michael G; Ashby, Rachel K; Ginsburg, Elizabeth S

    2018-03-01

    To report on the unique, innovative management of a super morbidly obese patient presenting for fertility preservation in the setting of Grade 2 endometrioid endometrial adenocarcinoma. A back-to-back oocyte retrieval and robot-assisted total laparoscopic hysterectomy (RA-TLH) with bilateral salpingo-oophorectomy (BSO) was performed in a 37-year-old nulligravid woman with super morbid obesity (BMI 63 kg/m 2 ) with endometrial cancer. the successful retrieval of oocytes for fertility preservation and oncologic intervention via RA-TLH with BSO in the same operative and anesthetic episode. This combined procedure strategy was successful in our case and is a feasible option for similar high-risk patients in the future. Identifying safe and effective approaches for oocyte retrieval in morbidly obese patients represents a pressing need as obesity rates rise among reproductive-aged women. Back-to-back oocyte retrieval and RA-TLH with BSO are not only feasible, but could also decrease significant anesthetic risks for morbidly obese patients. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  13. Robotic-assisted partial nephrectomy: surgical technique using a 3-arm approach and sliding-clip renorrhaphy

    Directory of Open Access Journals (Sweden)

    Jose M. Cabello

    2009-04-01

    Full Text Available INTRODUCTION: For the treatment of renal tumors, minimally invasive nephron-sparing surgery has become increasingly performed due to proven efficiency and excellent functional and oncological outcomes. The introduction of robotics into urologic laparoscopic surgery has allowed surgeons to perform challenging procedures in a reliable and reproducible manner. We present our surgical technique for robotic assisted partial nephrectomy (RPN using a 3-arm approach, including a sliding-clip renorrhaphy. MATERIAL AND METHODS: Our RPN technique is presented which describes the trocar positioning, hilar dissection, tumor identification using intraoperative ultrasound for margin determination, selective vascular clamping, tumor resection, and reconstruction using a sliding-clip technique. CONCLUSION: RPN using a sliding-clip renorrhaphy is a valid and reproducible surgical technique that reduces the challenge of the procedure by taking advantage of the enhanced visualization and control afforded by the robot. The renorrhaphy described is performed under complete control of the console surgeon, and has demonstrated a reduction in the warm ischemia times in our series.

  14. Integration of force reflection with tactile sensing for minimally invasive robotics-assisted tumor localization.

    Science.gov (United States)

    Talasaz, A; Patel, R V

    2013-01-01

    Tactile sensing and force reflection have been the subject of considerable research for tumor localization in soft-tissue palpation. The work presented in this paper investigates the relevance of force feedback (presented visually as well as directly) during tactile sensing (presented visually only) for tumor localization using an experimental setup close to one that could be applied for real robotics-assisted minimally invasive surgery. The setup is a teleoperated (master-slave) system facilitated with a state-of-the-art minimally invasive probe with a rigidly mounted tactile sensor at the tip and an externally mounted force sensor at the base of the probe. The objective is to capture the tactile information and measure the interaction forces between the probe and tissue during palpation and to explore how they can be integrated to improve the performance of tumor localization. To quantitatively explore the effect of force feedback on tactile sensing tumor localization, several experiments were conducted by human subjects to locate artificial tumors embedded in the ex vivo bovine livers. The results show that using tactile sensing in a force-controlled environment can realize, on average, 57 percent decrease in the maximum force and 55 percent decrease in the average force applied to tissue while increasing the tumor detection accuracy by up to 50 percent compared to the case of using tactile feedback alone. The results also show that while visual presentation of force feedback gives straightforward quantitative measures, improved performance of tactile sensing tumor localization is achieved at the expense of longer times for the user. Also, the quickness and intuitive data mapping of direct force feedback makes it more appealing to experienced users.

  15. Pelvic lymph node dissection during robot-assisted radical prostatectomy: efficacy, limitations, and complications-a systematic review of the literature.

    Science.gov (United States)

    Ploussard, Guillaume; Briganti, Alberto; de la Taille, Alexandre; Haese, Alexander; Heidenreich, Axel; Menon, Mani; Sulser, Tullio; Tewari, Ashutosh K; Eastham, James A

    2014-01-01

    Pelvic lymph node dissection (PLND) in prostate cancer is the most effective method for detecting lymph node metastases. However, a decline in the rate of PLND during radical prostatectomy (RP) has been noted. This is likely the result of prostate cancer stage migration in the prostate-specific antigen-screening era, and the introduction of minimally invasive approaches such as robot-assisted radical prostatectomy (RARP). To assess the efficacy, limitations, and complications of PLND during RARP. A review of the literature was performed using the Medline, Scopus, and Web of Science databases with no restriction of language from January 1990 to December 2012. The literature search used the following terms: prostate cancer, radical prostatectomy, robot-assisted, and lymph node dissection. The median value of nodal yield at PLND during RARP ranged from 3 to 24 nodes. As seen in open and laparoscopic RP series, the lymph node positivity rate increased with the extent of dissection during RARP. Overall, PLND-only related complications are rare. The most frequent complication after PLND is symptomatic pelvic lymphocele, with occurrence ranging from 0% to 8% of cases. The rate of PLND-associated grade 3-4 complications ranged from 0% to 5%. PLND is associated with increased operative time. Available data suggest equivalence of PLND between RARP and other surgical approaches in terms of nodal yield, node positivity, and intraoperative and postoperative complications. PLND during RARP can be performed effectively and safely. The overall number of nodes removed, the likelihood of node positivity, and the types and rates of complications of PLND are similar to pure laparoscopic and open retropubic procedures. Copyright © 2013 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  16. Robot-assisted laparoscopic radical cystectomy with extracorporeal urinary diversion: Initial experience and outcomes

    Directory of Open Access Journals (Sweden)

    Nitin Shrivastava

    2018-01-01

    Conclusion: This study shows the feasibility and safety of RARC. The operative time, blood loss, return of bowel activity and hospital stay were higher than those reported in the literature but may reflect the learning curve.

  17. The effect of music on robot-assisted laparoscopic surgical performance.

    Science.gov (United States)

    Siu, Ka-Chun; Suh, Irene H; Mukherjee, Mukul; Oleynikov, Dmitry; Stergiou, Nick

    2010-12-01

    Music is often played in the operating room to increase the surgeon's concentration and to mask noise. It could have a beneficial effect on surgical performance. Ten participants with limited experience with the da Vinci robotic surgical system were recruited to perform two surgical tasks: suture tying and mesh alignment when classical, jazz, hip-hop, and Jamaican music were presented. Kinematics of the instrument tips of the surgical robot and surface electromyography of the subjects were recorded. Results revealed that a significant music effect was found for both tasks with decreased time to task completion (P = .005) and total travel distance (P = .021) as well as reduced muscle activations ( P = .016) and increased median muscle frequency (P = .034). Subjects improved their performance significantly when they listened to either hip-hop or Jamaican music. In conclusion, music with high rhythmicity has a beneficial effect on robotic surgical performance. Musical environment may benefit surgical training and make acquisition of surgical skills more efficient.

  18. Total intravenous anaesthesia versus inhalational anaesthesia for adults undergoing transabdominal robotic assisted laparoscopic surgery

    DEFF Research Database (Denmark)

    Herling, Suzanne Forsyth; Dreijer, Bjørn; Wrist Lam, Gitte

    2017-01-01

    ), the Cumulative Index to Nursing and Allied Health Literature (CINAHL) via EBSCOhost (1982 to May 2016) and the Institute for Scientific Information (ISI) Web of Science (1956 to May 2016). We also searched the International Standard Randomized Controlled Trial Number (ISRCTN) Registry and Clinical trials gov...... an increase in intraocular pressure (IOP) after pneumoperitoneum and steep Trendelenburg positioning compared with sevoflurane (MD -3.90, 95% CI -6.34 to -1.46; P = 0.002) with increased IOP from baseline to 30 minutes in steep Trendelenburg. However, it is unclear whether this surrogate outcome translates...

  19. Port-site metastases following robot-assisted laparoscopic surgery for gynecological malignancies.

    Science.gov (United States)

    Lönnerfors, Celine; Bossmar, Thomas; Persson, Jan

    2013-12-01

    To evaluate the incidence and possible predictors associated with port-site metastases following robotic surgery. Prospective study. University Hospital. Women with gynecological cancer. The occurrence of port-site metastases in the first 475 women undergoing robotic surgery for gynecological cancer was reviewed. Rate of port-site metastases. A port-site metastasis was detected in nine of 475 women (1.9%). Eight women had either an unexpected locally advanced disease or lymph-node metastases at the time of surgery. All nine women received postoperative adjuvant therapy. Women with ≥ stage III endometrial cancer and women with node positive cervical cancer had a significantly higher risk of developing a port-site metastasis, as did women with high-risk histology endometrial cancer. Port-site metastases were four times more likely to occur in a specimen-retrieval port. One (0.2%) isolated port-site metastasis was detected. The median time to occurrence of a port-site metastasis was 6 months (range 2-19 months). Six of the nine women (67%) have died and their median time of survival from recurrence was 4 months (range 2-16 months). In women with gynecological cancer, the incidence of port-site metastases following robotic surgery was 1.9%. High-risk histology and/or advanced stage of disease at surgery seem to be contributing factors. © 2013 Nordic Federation of Societies of Obstetrics and Gynecology.

  20. Standardized analysis of laparoscopic and robotic-assisted partial nephrectomy complications with Clavien classification

    Directory of Open Access Journals (Sweden)

    Chia-Min Yang

    2014-12-01

    Conclusion: The overall complication rate in the present study was comparable to that reported in previous studies, although our patients had a larger mean tumor size and higher-complexity procedures.

  1. Robotic-assisted laparoscopic surgery in urology:a historical perspective

    Directory of Open Access Journals (Sweden)

    Nikhil L Shah

    2005-01-01

    Full Text Available Significant improvements in the surgical approaches and management of disease have been made since the advent of antiseptic surgical technique and the widespread use of antibiotics. During the last quarter century, especially in the last decade, however, there has been an indisputable paradigm shift toward the use of minimally invasive surgery for treatment of a variety of diseases. This has benefited the patient in terms of lower morbidity and mortality through less violation of the body′s natural protective boundaries. The morbidity in terms of pain, discomfort, and disability often associated with open surgery is due to the process of gaining access to the specific organ or region of interest as opposed to the actual procedure itself. Put another way, the move toward minimally invasive approaches for surgical disease has resulted in superior outcomes, fewer complications, and an overall improvement in health-related quality of life (HRQOL.

  2. Impact of metabolic syndrome on early recovery of continence after robot-assisted radical prostatectomy.

    Science.gov (United States)

    Nishikawa, Masatomo; Watanabe, Hiromitsu; Kurahashi, Toshifumi

    2017-09-01

    To evaluate the impact of metabolic syndrome on the early recovery of urinary continence after robot-assisted radical prostatectomy. The present study included a total of 302 consecutive Japanese patients with clinically localized prostate cancer who underwent robot-assisted radical prostatectomy. In this study, postoperative urinary continence was defined as no leak or the use of a security pad. The continence status was assessed by interviews before and 1 and 3 months after robot-assisted radical prostatectomy. Metabolic syndrome was defined as follows: body mass index ≥25 kg/m 2 and two or more of the following: hypertension, diabetes mellitus and dyslipidemia. The effect of the presence of metabolic syndrome on the continence status of these patients was retrospectively examined. A total of 116 (38.4%) and 203 (67.2%) of the 302 patients were continent at 1 and 3 months after robot-assisted radical prostatectomy, respectively. A total of 31 (10.3%) patients were judged to have metabolic syndrome. Despite the operative time being longer in patients with metabolic syndrome, no significant differences were observed in the remaining preoperative, intraoperative or postoperative variables between patients with or without metabolic syndrome. On multivariate logistic regression analysis, metabolic syndrome and the duration of hospitalization were significantly correlated with the 1-month continence status. Similarly, metabolic syndrome and estimated blood loss during surgery were independent predictors of continence rates at 3 months after robot-assisted radical prostatectomy. These findings suggest that the presence of metabolic syndrome could have a significant impact on the early recovery of urinary continence after robot-assisted radical prostatectomy. © 2017 The Japanese Urological Association.

  3. Predictors of Incisional Hernia after Robotic Assisted Radical Prostatectomy

    Directory of Open Access Journals (Sweden)

    Avinash Chennamsetty

    2015-01-01

    Full Text Available Introduction. To explore the long term incidence and predictors of incisional hernia in patients that had RARP. Methods. All patients who underwent RARP between 2003 and 2012 were mailed a survey reviewing hernia type, location, and repair. Results. Of 577 patients, 48 (8.3% had a hernia at an incisional site (35 men had umbilical, diagnosed at (median 1.2 years after RARP (mean follow-up of 5.05 years. No statistically significant differences were found in preoperative diabetes, smoking, pathological stage, age, intraoperative/postoperative complications, operative time, blood loss, BMI, and drain type between patients with and without incisional hernias. Incisional hernia patients had larger median prostate weight (45 versus 38 grams; P=0.001 and a higher proportion had prior laparoscopic cholecystectomy (12.5% (6/48 versus 4.6% (22/480; P=0.033. Overall, 4% (23/577 of patients underwent surgical repair of 24 incisional hernias, 22 umbilical and 2 other port site hernias. Conclusion. Incisional hernia is a known complication of RARP and may be associated with a larger prostate weight and history of prior laparoscopic cholecystectomy. There is concern about the underreporting of incisional hernia after RARP, as it is a complication often requiring surgical revision and is of significance for patient counseling before surgery.

  4. Gastrointestinal robot-assisted surgery. A current perspective.

    Science.gov (United States)

    Lunca, Sorinel; Bouras, George; Stanescu, Alexandru Calin

    2005-12-01

    Minimally invasive techniques have revolutionized operative surgery. Computer aided surgery and robotic surgical systems strive to improve further on currently available minimally invasive surgery and open new horizons. Only several centers are currently using surgical robots and publishing data. In gastrointestinal surgery, robotic surgery is applied to a wide range of procedures, but is still in its infancy. Cholecystectomy, Nissen fundoplication and Heller myotomy are among the most frequently performed operations. The ZEUS (Computer Motion, Goleta, CA) and the da Vinci (Intuitive Surgical, Mountain View, CA) surgical systems are today the most advanced robotic systems used in gastrointestinal surgery. Most studies reported that robotic gastrointestinal surgery is feasible and safe, provides improved dexterity, better visualization, reduced fatigue and high levels of precision when compared to conventional laparoscopic surgery. Its main drawbacks are the absence of force feedback and extremely high costs. At this moment there are no reports to clearly demonstrate the superiority of robotics over conventional laparoscopic surgery. Further research and more prospective randomized trials are needed to better define the optimal application of this new technology in gastrointestinal surgery.

  5. Effect of Previous Abdominal Surgery on Laparoscopic Liver Resection: Analysis of Feasibility and Risk Factors for Conversion.

    Science.gov (United States)

    Cipriani, Federica; Ratti, Francesca; Fiorentini, Guido; Catena, Marco; Paganelli, Michele; Aldrighetti, Luca

    2018-03-28

    Previous abdominal surgery has traditionally been considered an additional element of difficulty to later laparoscopic procedures. The aim of the study is to analyze the effect of previous surgery on the feasibility and safety of laparoscopic liver resection (LLR), and its role as a risk factor for conversion. After matching, 349 LLR in patients known for previous abdominal surgery (PS group) were compared with 349 LLR on patients with a virgin abdomen (NPS group). Subgroup analysis included 161 patients with previous upper abdominal surgery (UPS subgroup). Feasibility and safety were evaluated in terms of conversion rate, reasons for conversion and outcomes, and risk factors for conversion assessed via uni/multivariable analysis. Conversion rate was 9.4%, and higher for PS patients compared with NPS patients (13.7% versus 5.1%, P = .021). Difficult adhesiolysis resulted the commonest reason for conversion in PS group (5.7%). However, operative time (P = .840), blood loss (P = .270), transfusion (P = .650), morbidity rate (P = .578), hospital stay (P = .780), and R1 rate (P = .130) were comparable between PS and NPS group. Subgroup analysis confirmed higher conversion rates for UPS patients (23%) compared with both NPS (P = .015) and PS patients (P = .041). Previous surgery emerged as independent risk factor for conversion (P = .033), alongside the postero-superior location and major hepatectomy. LLR are feasible in case of previous surgery and proved to be safe and maintain the benefits of LLR carried out in standard settings. However, a history of surgery should be considered a risk factor for conversion.

  6. Review of various liver retraction techniques in single incision laparoscopic surgery for the exposure of hiatus.

    Science.gov (United States)

    Palanivelu, Praveenraj; Patil, Kedar Pratap; Parthasarathi, Ramakrishnan; Viswambharan, Jaiganesh K; Senthilnathan, Palanisami; Palanivelu, Chinnusamy

    2015-01-01

    The main aspect of concern for upper GI procedures has been the retraction of the liver especially large left lobes as commonly encountered in Bariatric surgery. Not doing so would compromise the view of the hiatus, hence theoretically reducing the quality of the surgery and increasing the possibility of complications. The aim of this study was to review the various liver retraction techniques in single incision surgery being done at our institute and analyze them. A retrospective study of the various techniques and a subsequent analysis was made based on advantages and disadvantages of each method. Objectively a quantitative measure of hiatal exposure was done using a scoring system based on the grade of exposure after reviewing the surgical videos. From January 2011 to January 2013 total 104 patients underwent single incision surgery with the various liver retraction techniques with following grades of exposure -liver suspension tube technique with naso gastric tubing (2.11) and with corrugated drain (2.09) needlescopic method (1.2), Umbilical tape sling (1.95), crural stitch method (2.5). Needeloscopic method has the best grade of exposure and is the easiest to start with. The average time to create the liver retraction was 2.8 to 8.6 min.There was no procedure related morbidity or mortality. The mentioned liver retraction techniques are cost effective and easy to learn. We recommend using these techniques to have a good exposure of hiatus, without compromising the safety of surgery in single incision surgery.

  7. Robot-assisted rectopexy is a safe and feasible option for treatment of rectal prolapse

    DEFF Research Database (Denmark)

    Haahr Raunkjær, Camilla; Jakobsen, Henrik Loft; Gögenur, Ismail

    2014-01-01

    INTRODUCTION: Rectal prolapse is seen in up to one in 100 elderly women and results in symptoms such as incontinence, mucus secretion and constipation. The aim of this study was to present short- and longterm outcomes after robot-assisted rectopexy in patients with rectal prolapse. MATERIAL AND M...

  8. Decoding sensorimotor rhythms during robotic-assisted treadmill walking for brain computer interface (BCI) applications

    NARCIS (Netherlands)

    Garcia Cossio, E.; Severens, M.; Nienhuis, B.; Duysens, J.; Desain, P.; Keijsers, N.; Farquhar, J.

    2015-01-01

    Locomotor malfunction represents a major problem in some neurological disorders like stroke and spinal cord injury. Robot-assisted walking devices have been used during rehabilitation of patients with these ailments for regaining and improving walking ability. Previous studies showed the advantage

  9. End-point impedance measurements across dominant and nondominant hands and robotic assistance with directional damping.

    Science.gov (United States)

    Erden, Mustafa Suphi; Billard, Aude

    2015-06-01

    The goal of this paper is to perform end-point impedance measurements across dominant and nondominant hands while doing airbrush painting and to use the results for developing a robotic assistance scheme. We study airbrush painting because it resembles in many ways manual welding, a standard industrial task. The experiments are performed with the 7 degrees of freedom KUKA lightweight robot arm. The robot is controlled in admittance using a force sensor attached at the end-point, so as to act as a free-mass and be passively guided by the human. For impedance measurements, a set of nine subjects perform 12 repetitions of airbrush painting, drawing a straight-line on a cartoon horizontally placed on a table, while passively moving the airbrush mounted on the robot's end-point. We measure hand impedance during the painting task by generating sudden and brief external forces with the robot. The results show that on average the dominant hand displays larger impedance than the nondominant in the directions perpendicular to the painting line. We find the most significant difference in the damping values in these directions. Based on this observation, we develop a "directional damping" scheme for robotic assistance and conduct a pilot study with 12 subjects to contrast airbrush painting with and without robotic assistance. Results show significant improvement in precision with both dominant and nondominant hands when using robotic assistance.

  10. Validation of in-line surface characterization by light scattering in Robot Assisted Polishing

    DEFF Research Database (Denmark)

    Pilny, Lukas; Bissacco, Giuliano; De Chiffre, Leonardo

    2014-01-01

    The suitability of a commercial scattered light sensor for in-line characterization of fine surfaces in the roughness range Sa 1 – 30 nm generated by the Robot Assisted Polishing (RAP) was investigated and validated. A number of surfaces were generated and directly measured with the scattered light...

  11. Robot-assisted placement of depth electrodes along the long Axis of the amygdalohippocampal complex

    Directory of Open Access Journals (Sweden)

    Alvin Y. Chan

    2016-12-01

    Conclusions: We have developed the Robot-Assisted Lateral Transoccipital Approach (RALTA, which is an advantageous technique for placing bilateral amygdalohippocampal depth electrodes using robotic guidance. Benefits of this technique include fewer electrodes required per patient and ease of positioning compared with seated or prone positioning.

  12. Matching technologies of home automation, robotics, assistance, geriatric telecare and telemedicine

    NARCIS (Netherlands)

    Franchimon, F.; Brink, M.

    2009-01-01

    The aging society could have a greater societal impact than the current financial crisis. The percentage of older adults has increased while the size of the health care workforce has remained constant. Home automation, robotics, assistive technology, geriatric telecare and telemedicine can support

  13. Robotic Assistance by Impedance Compensation for Hand Movements While Manual Welding.

    Science.gov (United States)

    Erden, Mustafa Suphi; Billard, Aude

    2016-11-01

    In this paper, we present a robotic assistance scheme which allows for impedance compensation with stiffness, damping, and mass parameters for hand manipulation tasks and we apply it to manual welding. The impedance compensation does not assume a preprogrammed hand trajectory. Rather, the intention of the human for the hand movement is estimated in real time using a smooth Kalman filter. The movement is restricted by compensatory virtual impedance in the directions perpendicular to the estimated direction of movement. With airbrush painting experiments, we test three sets of values for the impedance parameters as inspired from impedance measurements with manual welding. We apply the best of the tested sets for assistance in manual welding and perform welding experiments with professional and novice welders. We contrast three conditions: 1) welding with the robot's assistance; 2) with the robot when the robot is passive; and 3) welding without the robot. We demonstrate the effectiveness of the assistance through quantitative measures of both task performance and perceived user's satisfaction. The performance of both the novice and professional welders improves significantly with robotic assistance compared to welding with a passive robot. The assessment of user satisfaction shows that all novice and most professional welders appreciate the robotic assistance as it suppresses the tremors in the directions perpendicular to the movement for welding.

  14. Systematic review and cumulative analysis of perioperative outcomes and complications after robot-assisted radical cystectomy

    DEFF Research Database (Denmark)

    Novara, Giacomo; Catto, James W F; Wilson, Timothy

    2015-01-01

    and complications of RARC in comparison with ORC and LRC. EVIDENCE ACQUISITION: Medline, Scopus, and Web of Science databases were searched using a free-text protocol including the terms robot-assisted radical cystectomy or da Vinci radical cystectomy or robot* radical cystectomy. RARC case series and studies...

  15. Human likeness: cognitive and affective factors affecting adoption of robot-assisted learning systems

    Science.gov (United States)

    Yoo, Hosun; Kwon, Ohbyung; Lee, Namyeon

    2016-07-01

    With advances in robot technology, interest in robotic e-learning systems has increased. In some laboratories, experiments are being conducted with humanoid robots as artificial tutors because of their likeness to humans, the rich possibilities of using this type of media, and the multimodal interaction capabilities of these robots. The robot-assisted learning system, a special type of e-learning system, aims to increase the learner's concentration, pleasure, and learning performance dramatically. However, very few empirical studies have examined the effect on learning performance of incorporating humanoid robot technology into e-learning systems or people's willingness to accept or adopt robot-assisted learning systems. In particular, human likeness, the essential characteristic of humanoid robots as compared with conventional e-learning systems, has not been discussed in a theoretical context. Hence, the purpose of this study is to propose a theoretical model to explain the process of adoption of robot-assisted learning systems. In the proposed model, human likeness is conceptualized as a combination of media richness, multimodal interaction capabilities, and para-social relationships; these factors are considered as possible determinants of the degree to which human cognition and affection are related to the adoption of robot-assisted learning systems.

  16. Exploring the ethical landscape of robot-assisted Search and Rescue

    NARCIS (Netherlands)

    Harbers, M.; Greeff, J. de; Kruijff-Korbayová, I.; Neerincx, M.A.; Hindriks, K.V.

    2017-01-01

    As robots are increasingly used in Search and Rescue (SAR) missions, it becomes highly relevant to study how SAR robots can be developed and deployed in a responsible way. In contrast to some other robot application domains, e.g. military and healthcare, the ethics of robot-assisted SAR are

  17. Rapid prototyping framework for robot-assisted training of autistic children

    NARCIS (Netherlands)

    Kim, Mingyu; Barakova, E.I.; Lourens, T.

    2014-01-01

    Research in uptake and actual use of robots in socially assistive tasks is rapidly growing. However, practical applications lack behind due to the enormous effort to create meaningful behaviours. This paper describes a rapid prototyping framework for robot-assisted training of children with Autism

  18. Development of a multisensory arm for process monitoring in Robot Assisted Polishing

    DEFF Research Database (Denmark)

    Pilny, Lukas; Dalla Costa, Giuseppe; Bissacco, Giuliano

    2015-01-01

    A multisensory polishing arm with integrated three component force sensor, a miniature acoustic emission (AE) sensor and an accelerometer was developed for process monitoring in Robot Assisted Polishing (RAP) process. The arm design was optimized for integration of a force and an AE sensor. The f...

  19. Hybrid procedure for total laryngectomy with a flexible robot-assisted surgical system.

    Science.gov (United States)

    Schuler, Patrick J; Hoffmann, Thomas K; Veit, Johannes A; Rotter, Nicole; Friedrich, Daniel T; Greve, Jens; Scheithauer, Marc O

    2017-06-01

    Total laryngectomy is a standard procedure in head-and-neck surgery for the treatment of cancer patients. Recent clinical experiences have indicated a clinical benefit for patients undergoing transoral robot-assisted total laryngectomy (TORS-TL) with commercially available systems. Here, a new hybrid procedure for total laryngectomy is presented. TORS-TL was performed in human cadavers (n = 3) using a transoral-transcervical hybrid procedure. The transoral approach was performed with a robotic flexible robot-assisted surgical system (Flex®) and compatible flexible instruments. Transoral access and visualization of anatomical landmarks were studied in detail. Total laryngectomy is feasible with a combined transoral-transcervical approach using the flexible robot-assisted surgical system. Transoral visualization of all anatomical structures is sufficient. The flexible design of the robot is advantageous for transoral surgery of the laryngeal structures. Transoral robot assisted surgery has the potential to reduce morbidity, hospital time and fistula rates in a selected group of patients. Initial clinical studies and further development of supplemental tools are in progress. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  20. Authoring Robot-Assisted Instructional Materials for Improving Learning Performance and Motivation in EFL Classrooms

    Science.gov (United States)

    Hong, Zeng-Wei; Huang, Yueh-Min; Hsu, Marie; Shen, Wei-Wei

    2016-01-01

    Anthropomorphized robots are regarded as beneficial tools in education due to their capabilities of improving teaching effectiveness and learning motivation. Therefore, one major trend of research, known as Robot- Assisted Language Learning (RALL), is trying to develop robots to support teaching and learning English as a foreign language (EFL). As…

  1. Learning curve for robotic-assisted surgery for rectal cancer: use of the cumulative sum method.

    Science.gov (United States)

    Yamaguchi, Tomohiro; Kinugasa, Yusuke; Shiomi, Akio; Sato, Sumito; Yamakawa, Yushi; Kagawa, Hiroyasu; Tomioka, Hiroyuki; Mori, Keita

    2015-07-01

    Few data are available to assess the learning curve for robotic-assisted surgery for rectal cancer. The aim of the present study was to evaluate the learning curve for robotic-assisted surgery for rectal cancer by a surgeon at a single institute. From December 2011 to August 2013, a total of 80 consecutive patients who underwent robotic-assisted surgery for rectal cancer performed by the same surgeon were included in this study. The learning curve was analyzed using the cumulative sum method. This method was used for all 80 cases, taking into account operative time. Operative procedures included anterior resections in 6 patients, low anterior resections in 46 patients, intersphincteric resections in 22 patients, and abdominoperineal resections in 6 patients. Lateral lymph node dissection was performed in 28 patients. Median operative time was 280 min (range 135-683 min), and median blood loss was 17 mL (range 0-690 mL). No postoperative complications of Clavien-Dindo classification Grade III or IV were encountered. We arranged operative times and calculated cumulative sum values, allowing differentiation of three phases: phase I, Cases 1-25; phase II, Cases 26-50; and phase III, Cases 51-80. Our data suggested three phases of the learning curve in robotic-assisted surgery for rectal cancer. The first 25 cases formed the learning phase.

  2. Exploring requirements and alternative pet robots for robot assisted therapy with older adults with dementia

    NARCIS (Netherlands)

    P Martinez-Martim; J. Albo-Canals; S. Anisuzzaman; Marcel Heerink; M. Valenti-Soler; J. Zondag; C. Smits

    2013-01-01

    Robot assisted therapy has been applied in care for older adults who suffer from dementia for over ten years. Strong effects like improved interac-tion and signs of a higher sense of wellbeing have been reported. Still it is un-clear which features are needed and which robotic pets would are

  3. Manufacture of functional surfaces through combined application of tool manufacturing processes and Robot Assisted Polishing

    DEFF Research Database (Denmark)

    Eriksen, Rasmus Solmer; Arentoft, Mogens; Grønbæk, J.

    2012-01-01

    The tool surface topography is often a key parameter in the tribological performance of modern metal forming tools. A new generation of multifunctional surfaces is achieved by combination of conventional tool manufacturing processes with a novel Robot Assisted Polishing process. This novel surface...

  4. Robotic-Assisted Versus Manual Prostatic Arterial Embolization for Benign Prostatic Hyperplasia: A Comparative Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Bagla, Sandeep, E-mail: sandeep.bagla@gmail.com [Vascular Institute of Virginia, LLC (United States); Smirniotopoulos, John [New York Presbyterian Hospital/Weill Cornell Medical Center (United States); Orlando, Julie C.; Piechowiak, Rachel [Vascular Institute of Virginia, LLC (United States)

    2017-03-15

    PurposeProstatic artery embolization (PAE) is a safe and efficacious procedure for benign prostatic hyperplasia (BPH), though is technically challenging. We present our experience of technical and clinical outcomes of robotic and manual PAE in patients with BPH.Materials and MethodsIRB-approved retrospective study of 40 consecutive patients 49–81 years old with moderate or severe grade BPH from May 2014 to July 2015: 20 robotic-assisted PAE (group 1), 20 manual PAE (group 2). Robotic-assisted PAE was performed using the Magellan Robotic System. American Urological Association (AUA-SI) score, cost, technical and clinical success, radiation dose, fluoroscopy, and procedure time were reviewed. Statistical analysis was performed within and between each group using paired t test and one-way analysis of variance respectively, at 1 and 3 months.ResultsNo significant baseline differences in age and AUA-SI between groups. Technical success was 100% (group 1) and 95% (group 2). One unsuccessful subject from group 2 returned for a successful embolization using robotic assistance. Fluoroscopy and procedural times were similar between groups, with a non-significant lower patient radiation dose in group 1 (30,632.8 mGy/cm{sup 2} vs 35,890.9, p = 0.269). Disposable cost was significantly different between groups with the robotic-assisted PAE incurring a higher cost (group 1 $4530.2; group 2 $1588.5, p < 0.0001). Clinical improvement was significant in both arms at 3 months: group 1 mean change in AUA-SI of 8.3 (p = 0.006), group 2: 9.6 (p < 0.0001). No minor or major complications occurred.ConclusionsRobotic-assisted PAE offers technical success comparable to manual PAE, with similar clinical improvement with an increased cost.

  5. Robotic Assistance for Training Finger Movement Using a Hebbian Model: A Randomized Controlled Trial.

    Science.gov (United States)

    Rowe, Justin B; Chan, Vicky; Ingemanson, Morgan L; Cramer, Steven C; Wolbrecht, Eric T; Reinkensmeyer, David J

    2017-08-01

    Robots that physically assist movement are increasingly used in rehabilitation therapy after stroke, yet some studies suggest robotic assistance discourages effort and reduces motor learning. To determine the therapeutic effects of high and low levels of robotic assistance during finger training. We designed a protocol that varied the amount of robotic assistance while controlling the number, amplitude, and exerted effort of training movements. Participants (n = 30) with a chronic stroke and moderate hemiparesis (average Box and Blocks Test 32 ± 18 and upper extremity Fugl-Meyer score 46 ± 12) actively moved their index and middle fingers to targets to play a musical game similar to GuitarHero 3 h/wk for 3 weeks. The participants were randomized to receive high assistance (causing 82% success at hitting targets) or low assistance (55% success). Participants performed ~8000 movements during 9 training sessions. Both groups improved significantly at the 1-month follow-up on functional and impairment-based motor outcomes, on depression scores, and on self-efficacy of hand function, with no difference between groups in the primary endpoint (change in Box and Blocks). High assistance boosted motivation, as well as secondary motor outcomes (Fugl-Meyer and Lateral Pinch Strength)-particularly for individuals with more severe finger motor deficits. Individuals with impaired finger proprioception at baseline benefited less from the training. Robot-assisted training can promote key psychological outcomes known to modulate motor learning and retention. Furthermore, the therapeutic effectiveness of robotic assistance appears to derive at least in part from proprioceptive stimulation, consistent with a Hebbian plasticity model.

  6. Robotic-Assisted Versus Manual Prostatic Arterial Embolization for Benign Prostatic Hyperplasia: A Comparative Analysis

    International Nuclear Information System (INIS)

    Bagla, Sandeep; Smirniotopoulos, John; Orlando, Julie C.; Piechowiak, Rachel

    2017-01-01

    PurposeProstatic artery embolization (PAE) is a safe and efficacious procedure for benign prostatic hyperplasia (BPH), though is technically challenging. We present our experience of technical and clinical outcomes of robotic and manual PAE in patients with BPH.Materials and MethodsIRB-approved retrospective study of 40 consecutive patients 49–81 years old with moderate or severe grade BPH from May 2014 to July 2015: 20 robotic-assisted PAE (group 1), 20 manual PAE (group 2). Robotic-assisted PAE was performed using the Magellan Robotic System. American Urological Association (AUA-SI) score, cost, technical and clinical success, radiation dose, fluoroscopy, and procedure time were reviewed. Statistical analysis was performed within and between each group using paired t test and one-way analysis of variance respectively, at 1 and 3 months.ResultsNo significant baseline differences in age and AUA-SI between groups. Technical success was 100% (group 1) and 95% (group 2). One unsuccessful subject from group 2 returned for a successful embolization using robotic assistance. Fluoroscopy and procedural times were similar between groups, with a non-significant lower patient radiation dose in group 1 (30,632.8 mGy/cm"2 vs 35,890.9, p = 0.269). Disposable cost was significantly different between groups with the robotic-assisted PAE incurring a higher cost (group 1 $4530.2; group 2 $1588.5, p < 0.0001). Clinical improvement was significant in both arms at 3 months: group 1 mean change in AUA-SI of 8.3 (p = 0.006), group 2: 9.6 (p < 0.0001). No minor or major complications occurred.ConclusionsRobotic-assisted PAE offers technical success comparable to manual PAE, with similar clinical improvement with an increased cost.

  7. From Leonardo to da Vinci: the history of robot-assisted surgery in urology.

    Science.gov (United States)

    Yates, David R; Vaessen, Christophe; Roupret, Morgan

    2011-12-01

    What's known on the subject? and What does the study add? Numerous urological procedures can now be performed with robotic assistance. Though not definitely proven to be superior to conventional laparoscopy or traditional open surgery in the setting of a randomised trial, in experienced centres robot-assisted surgery allows for excellent surgical outcomes and is a valuable tool to augment modern surgical practice. Our review highlights the depth of history that underpins the robotic surgical platform we utilise today, whilst also detailing the current place of robot-assisted surgery in urology in 2011. The evolution of robots in general and as platforms to augment surgical practice is an intriguing story that spans cultures, continents and centuries. A timeline from Yan Shi (1023-957 bc), Archytas of Tarentum (400 bc), Aristotle (322 bc), Heron of Alexandria (10-70 ad), Leonardo da Vinci (1495), the Industrial Revolution (1790), 'telepresence' (1950) and to the da Vinci(®) Surgical System (1999), shows the incredible depth of history and development that underpins the modern surgical robot we use to treat our patients. Robot-assisted surgery is now well-established in Urology and although not currently regarded as a 'gold standard' approach for any urological procedure, it is being increasingly used for index operations of the prostate, kidney and bladder. We perceive that robotic evolution will continue infinitely, securing the place of robots in the history of Urological surgery. Herein, we detail the history of robots in general, in surgery and in Urology, highlighting the current place of robot-assisted surgery in radical prostatectomy, partial nephrectomy, pyeloplasty and radical cystectomy. © 2011 THE AUTHORS. BJU INTERNATIONAL © 2011 BJU INTERNATIONAL.

  8. Review of various liver retraction techniques in single incision laparoscopic surgery for the exposure of hiatus

    Directory of Open Access Journals (Sweden)

    Praveenraj Palanivelu

    2015-01-01

    Full Text Available Background: The main aspect of concern for upper GI procedures has been the retraction of the liver especially large left lobes as commonly encountered in Bariatric surgery. Not doing so would compromise the view of the hiatus, hence theoretically reducing the quality of the surgery and increasing the possibility of complications. The aim of this study was to review the various liver retraction techniques in single incision surgery being done at our institute and analyze them. Material and Methods: A retrospective study of the various techniques and a subsequent analysis was made based on advantages and disadvantages of each method. Objectively a quantitative measure of hiatal exposure was done using a scoring system based on the grade of exposure after reviewing the surgical videos. From January 2011 to January 2013 total 104 patients underwent single incision surgery with the various liver retraction techniques with following grades of exposure -liver suspension tube technique with naso gastric tubing (2.11 and with corrugated drain (2.09 needlescopic method (1.2, Umbilical tape sling (1.95, crural stitch method (2.5. Needeloscopic method has the best grade of exposure and is the easiest to start with. The average time to create the liver retraction was 2.8 to 8.6 min.There was no procedure related morbidity or mortality. Conclusions: The mentioned liver retraction techniques are cost effective and easy to learn. We recommend using these techniques to have a good exposure of hiatus, without compromising the safety of surgery in single incision surgery.

  9. Robot-assisted walking with the Lokomat: the influence of different levels of guidance force on thorax and pelvis kinematics.

    Science.gov (United States)

    Swinnen, Eva; Baeyens, Jean-Pierre; Knaepen, Kristel; Michielsen, Marc; Clijsen, Ron; Beckwée, David; Kerckhofs, Eric

    2015-03-01

    Little attention has been devoted to the thorax and pelvis movements during gait. The aim of this study is to compare differences in the thorax and pelvis kinematics during unassisted walking on a treadmill and during walking with robot assistance (Lokomat-system (Hocoma, Volketswil, Switzerland)). 18 healthy persons walked on a treadmill with and without the Lokomat system at 2kmph. Three different conditions of guidance force (30%, 60% and 100%) were used during robot-assisted treadmill walking (30% body weight support). The maximal movement amplitudes of the thorax and pelvis were measured (Polhemus Liberty™ (Polhemus, Colchester, Vermont, USA) (240/16)). A repeated measurement ANOVA was conducted. Robot-assisted treadmill walking with different levels of guidance force showed significantly smaller maximal movement amplitudes for thorax and pelvis, compared to treadmill walking. Only the antero-posterior tilting of the pelvis was significantly increased during robot-assisted treadmill walking compared to treadmill walking. No significant changes of kinematic parameters were found between the different levels of guidance force. With regard to the thorax and pelvis movements, robot-assisted treadmill walking is significantly different compared to treadmill walking. It can be concluded that when using robot assistance, the thorax is stimulated in a different way than during walking without robot assistance, influencing the balance training during gait. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Laparoscopic Sleeve Gastrectomy for Morbid Obesity in Patients After Orthotopic Liver Transplant: a Matched Case-Control Study.

    Science.gov (United States)

    Tsamalaidze, Levan; Stauffer, John A; Arasi, Lisa C; Villacreses, Diego E; Franco, Jose Salvador Serrano; Bowers, Steven; Elli, Enrique F

    2018-02-01

    Obesity is frequently encountered in patients with orthotopic liver transplant (OLT). The role of bariatric surgery is still unclear for this specific population. The aim of this study was to review our experience with laparoscopic sleeve gastrectomy (LSG) after OLT. We performed a retrospective case-control study of patients undergoing LSG after OLT from 2010 to 2016. OLT-LSG patients were matched by age, sex, body mass index (BMI), and year to non-OLT patients undergoing LSG. Demographics, operative variables, postoperative events, and long-term weight loss with comorbidity resolution were collected and compared between cases and controls. Of 303 patients undergoing LSG, 12 (4%) had previous OLT. They were matched to 36 non-OLT patients. No difference was found between groups in the American Society of Anesthesiologists class, mean operative time, or postoperative morbidity. The non-OLT group, however, had a significantly shorter mean hospital stay than the OLT group (1.7 vs 3.1 days; P OLT patients had significantly more excess body weight loss at 2 years (53.7 vs 45.2%; P OLT in appropriately selected patients appears to have similar outcomes to LSG in non-OLT patients.

  11. Impact of laparoscopic surgery training laboratory on surgeon's performance

    Science.gov (United States)

    Torricelli, Fabio C M; Barbosa, Joao Arthur B A; Marchini, Giovanni S

    2016-01-01

    Minimally invasive surgery has been replacing the open standard technique in several procedures. Similar or even better postoperative outcomes have been described in laparoscopic or robot-assisted procedures when compared to open surgery. Moreover, minimally invasive surgery has been providing less postoperative pain, shorter hospitalization, and thus a faster return to daily activities. However, the learning curve required to obtain laparoscopic expertise has been a barrier in laparoscopic spreading. Laparoscopic surgery training laboratory has been developed to aid surgeons to overcome the challenging learning curve. It may include tutorials, inanimate model skills training (box models and virtual reality simulators), animal laboratory, and operating room observation. Several different laparoscopic courses are available with specific characteristics and goals. Herein, we aim to describe the activities performed in a dry and animal-model training laboratory and to evaluate the impact of different kinds of laparoscopic surgery training courses on surgeon’s performance. Several tasks are performed in dry and animal laboratory to reproduce a real surgery. A short period of training can improve laparoscopic surgical skills, although most of times it is not enough to confer laparoscopic expertise for participants. Nevertheless, this short period of training is able to increase the laparoscopic practice of surgeons in their communities. Full laparoscopic training in medical residence or fellowship programs is the best way of stimulating laparoscopic dissemination. PMID:27933135

  12. Robotic-Assisted Minimally Invasive Surgery for Gynecologic and Urologic Oncology

    Science.gov (United States)

    2010-01-01

    conventional laparoscopy surgery and allows for tremor-free manipulation. The main disadvantages of use of the robotic device are the costs including instrument costs ($2.6 million in US dollars), cost per use ($200 per use), the costs associated with training surgeons and operating room personnel, and the lack of tactile feedback, with the trade-off being increased visual feedback. Research Questions For endometrial and cervical cancers, 1. What is the effectiveness of the Da Vinci Surgical System vs. laparoscopy and laparotomy for women undergoing any hysterectomy for the surgical treatment and management of their endometrial and cervical cancers? 2. What are the incremental costs of the Da Vinci Surgical System vs. laparoscopy and laparotomy for women undergoing any hysterectomy for the surgical treatment and management of their endometrial and cervical cancers? For prostate cancer, 3. What is the effectiveness of robotically-assisted radical prostatectomy using the Da Vinci Surgical System vs. laparoscopic radical prostatectomy and retropubic radical prostatectomy for the surgical treatment and management of prostate cancer? 4. What are the incremental costs of robotically-assisted radical prostatectomy using the Da Vinci Surgical System vs. laparoscopic radical prostatectomy and retropubic radical prostatectomy for the surgical treatment and management of prostate cancer? Research Methods Literature Search Search Strategy A literature search was performed on May 12, 2010 using OVID MEDLINE, MEDLINE In-Process and Other Non-Indexed Citations, OVID EMBASE, Wiley Cochrane, CINAHL, Centre for Reviews and Dissemination/International Agency for Health Technology Assessment for studies published from January 1, 2000 until May 12, 2010. Abstracts were reviewed by a single reviewer and, for those studies meeting the eligibility criteria, full-text articles were obtained. Reference lists were also examined for any additional relevant studies not identified through the search

  13. Initial experiences of simultaneous laparoscopic resection of colorectal cancer and liver metastases

    NARCIS (Netherlands)

    Hoekstra, L. T.; Busch, O. R. C.; Bemelman, W. A.; van Gulik, T. M.; Tanis, P. J.

    2012-01-01

    Introduction. Simultaneous resection of primary colorectal carcinoma (CRC) and synchronous liver metastases (SLMs) is subject of debate with respect to morbidity in comparison to staged resection. The aim of this study was to evaluate our initial experience with this approach. Methods. Five patients

  14. Long-term survival in laparoscopic vs open resection for colorectal liver metastases: inverse probability of treatment weighting using propensity scores.

    Science.gov (United States)

    Lewin, Joel W; O'Rourke, Nicholas A; Chiow, Adrian K H; Bryant, Richard; Martin, Ian; Nathanson, Leslie K; Cavallucci, David J

    2016-02-01

    This study compares long-term outcomes between intention-to-treat laparoscopic and open approaches to colorectal liver metastases (CLM), using inverse probability of treatment weighting (IPTW) based on propensity scores to control for selection bias. Patients undergoing liver resection for CLM by 5 surgeons at 3 institutions from 2000 to early 2014 were analysed. IPTW based on propensity scores were generated and used to assess the marginal treatment effect of the laparoscopic approach via a weighted Cox proportional hazards model. A total of 298 operations were performed in 256 patients. 7 patients with planned two-stage resections were excluded leaving 284 operations in 249 patients for analysis. After IPTW, the population was well balanced. With a median follow up of 36 months, 5-year overall survival (OS) and recurrence-free survival (RFS) for the cohort were 59% and 38%. 146 laparoscopic procedures were performed in 140 patients, with weighted 5-year OS and RFS of 54% and 36% respectively. In the open group, 138 procedures were performed in 122 patients, with a weighted 5-year OS and RFS of 63% and 38% respectively. There was no significant difference between the two groups in terms of OS or RFS. In the Brisbane experience, after accounting for bias in treatment assignment, long term survival after LLR for CLM is equivalent to outcomes in open surgery. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  15. Patterns-of-care and health economic analysis of robot-assisted radical prostatectomy in the Australian public health system.

    Science.gov (United States)

    Basto, Marnique; Sathianathen, Niranjan; Te Marvelde, Luc; Ryan, Shane; Goad, Jeremy; Lawrentschuk, Nathan; Costello, Anthony J; Moon, Daniel A; Heriot, Alexander G; Butler, Jim; Murphy, Declan G

    2016-06-01

    To compare patterns of care and peri-operative outcomes of robot-assisted radical prostatectomy (RARP) with other surgical approaches, and to create an economic model to assess the viability of RARP in the public case-mix funding system. We retrospectively reviewed all radical prostatectomies (RPs) performed for localized prostate cancer in Victoria, Australia, from the Victorian Admitted Episode Dataset, a large administrative database that records all hospital inpatient episodes in Victoria. The first database, covering the period from July 2010 to April 2013 (n = 5 130), was used to compare length of hospital stay (LOS) and blood transfusion rates between surgical approaches. This was subsequently integrated into an economic model. A second database (n = 5 581) was extracted to cover the period between July 2010 and June 2013, three full financial years, to depict patterns of care and make future predictions for the 2014-2015 financial year, and to perform a hospital volume analysis. We then created an economic model to evaluate the incremental cost of RARP vs open RP (ORP) and laparoscopic RP (LRP), incorporating the cost-offset from differences in LOS and blood transfusion rate. The economic model constructs estimates of the diagnosis-related group (DRG) costs of ORP and LRP, adds the gross cost of the surgical robot (capital, consumables, maintenance and repairs), and manipulates these DRG costs to obtain a DRG cost per day, which can be used to estimate the cost-offset associated with RARP in comparison with ORP and LRP. Economic modelling was performed around a base-case scenario, assuming a 7-year robot lifespan and 124 RARPs performed per financial year. One- and two-way sensitivity analyses were performed for the four-arm da Vinci SHD, Si and Si dual surgical systems (Intuitive Surgical Ltd, Sunnyvale, CA, USA). We identified 5 581 patients who underwent RP in 20 hospitals in Victoria with an open, laparoscopic or robot-assisted surgical approach in the

  16. Surgical Value of Elective Minimally Invasive Gallbladder Removal: A Cost Analysis of Traditional 4-Port vs Single-Incision and Robotically Assisted Cholecystectomy.

    Science.gov (United States)

    Newman, Richard M; Umer, Affan; Bozzuto, Bethany J; Dilungo, Jennifer L; Ellner, Scott

    2016-03-01

    As the cost of health care is subjected to increasingly greater scrutiny, the assessment of new technologies must include the surgical value (SV) of the procedure. Surgical value is defined as outcome divided by cost. The cost and outcome of 50 consecutive traditional (4-port) laparoscopic cholecystectomies (TLC) were compared with 50 consecutive, nontraditional laparoscopic cholecystectomies (NTLC), between October 2012 and February 2014. The NTLC included SILS (n = 11), and robotically assisted single-incision cholecystectomies (ROBOSILS; n = 39). Our primary outcomes included minimally invasive gallbladder removal and same-day discharge. Thirty-day emergency department visits or readmissions were evaluated as a secondary outcome. The direct variable surgeon costs (DVSC) were distilled from our hospital cost accounting system and calculated on a per-case, per item basis. The average DVSC for TLC was $929 and was significantly lower than NTLC at $2,344 (p day discharge. There were no differences observed in secondary outcomes in 30-day emergency department visits (TLC [2%] vs NTLC [6%], p = 0.61) or readmissions (TLC [4%] vs NTLC [2%], p > 0.05), respectively. The relative SV was significantly higher for TLC (1) compared with NTLC (0.34) (p < 0.05), and SILS (0.66) and ROBOSILS (0.36) (p < 0.05). Nontraditional, minimally invasive gallbladder removal (SILS and ROBOSILS) offers significantly less surgical value for elective, outpatient gallbladder removal. Copyright © 2016 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Robotic versus Laparoscopic Distal Pancreatectomy: A Meta-Analysis of Short-Term Outcomes.

    Science.gov (United States)

    Zhou, Jia-Yu; Xin, Chang; Mou, Yi-Ping; Xu, Xiao-Wu; Zhang, Miao-Zun; Zhou, Yu-Cheng; Lu, Chao; Chen, Rong-Gao

    2016-01-01

    To compare the safety and efficacy of robotic-assisted distal pancreatectomy (RADP) and laparoscopic distal pancreatectomy (LDP). A literature search of PubMed, EMBASE, and the Cochrane Library database up to June 30, 2015 was performed. The following key words were used: pancreas, distal pancreatectomy, pancreatic, laparoscopic, laparoscopy, robotic, and robotic-assisted. Fixed and random effects models were applied. Study quality was assessed using the Newcastle-Ottawa Scale. Seven non-randomized controlled trials involving 568 patients met the inclusion criteria. Compared with LDP, RADP was associated with longer operating time, lower estimated blood loss, a higher spleen-preservation rate, and shorter hospital stay. There was no significant difference in transfusion, conversion to open surgery, R0 resection rate, lymph nodes harvested, overall complications, severe complications, pancreatic fistula, severe pancreatic fistula, ICU stay, total cost, and 30-day mortality between the two groups. RADP is a safe and feasible alternative to LDP with regard to short-term outcomes. Further studies on the long-term outcomes of these surgical techniques are required. To date, there is no consensus on whether laparoscopic or robotic-assisted distal pancreatectomy is more beneficial to the patient. This is the first meta-analysis to compare laparoscopic and robotic-assisted distal pancreatectomy. We found that robotic-assisted distal pancreatectomy was associated with longer operating time, lower estimated blood loss, a higher spleen-preservation rate, and shorter hospital stay. There was no significant difference in transfusion, conversion to open surgery, overall complications, severe complications, pancreatic fistula, severe pancreatic fistula, ICU stay, total cost, and 30-day mortality between the two groups.

  18. Robotic versus Laparoscopic Distal Pancreatectomy: A Meta-Analysis of Short-Term Outcomes.

    Directory of Open Access Journals (Sweden)

    Jia-Yu Zhou

    Full Text Available To compare the safety and efficacy of robotic-assisted distal pancreatectomy (RADP and laparoscopic distal pancreatectomy (LDP.A literature search of PubMed, EMBASE, and the Cochrane Library database up to June 30, 2015 was performed. The following key words were used: pancreas, distal pancreatectomy, pancreatic, laparoscopic, laparoscopy, robotic, and robotic-assisted. Fixed and random effects models were applied. Study quality was assessed using the Newcastle-Ottawa Scale.Seven non-randomized controlled trials involving 568 patients met the inclusion criteria. Compared with LDP, RADP was associated with longer operating time, lower estimated blood loss, a higher spleen-preservation rate, and shorter hospital stay. There was no significant difference in transfusion, conversion to open surgery, R0 resection rate, lymph nodes harvested, overall complications, severe complications, pancreatic fistula, severe pancreatic fistula, ICU stay, total cost, and 30-day mortality between the two groups.RADP is a safe and feasible alternative to LDP with regard to short-term outcomes. Further studies on the long-term outcomes of these surgical techniques are required.To date, there is no consensus on whether laparoscopic or robotic-assisted distal pancreatectomy is more beneficial to the patient. This is the first meta-analysis to compare laparoscopic and robotic-assisted distal pancreatectomy. We found that robotic-assisted distal pancreatectomy was associated with longer operating time, lower estimated blood loss, a higher spleen-preservation rate, and shorter hospital stay. There was no significant difference in transfusion, conversion to open surgery, overall complications, severe complications, pancreatic fistula, severe pancreatic fistula, ICU stay, total cost, and 30-day mortality between the two groups.

  19. ROBOT-ASSISTED RADICAL PROSTATECTOMY: ANALYSIS OF THE FIRST 80 CASES

    Directory of Open Access Journals (Sweden)

    D. Yu. Pushkar

    2010-01-01

    Full Text Available Background. As a common disease, prostate cancer (PC has taken now first place among all malignancies in many countries of the world.The authors have analyzed the results of their series of robot-assisted radical laparoscopic prostatectomy (RALP in patients with PC. They also present a number of surgical techniques that may be useful for novice surgeons. Materials and methods. In November 2008 to November 2009, the Department of Urology, Moscow State University of Medicine and Dentistry, performed 80 RALPs using the da Vinci S surgical robotic system. The patients’ mean age was 63.7 (49–71 years; the mean blood level of total prostate-specific antigen was 6.1 (2.1–20.84 ng/ml; the mean prostate volume was 44 (18–94 cm3, as evidenced by transrectal ultrasound study. The authors analyzed the following indicators: operating time, degree of blood loss, conversion of surgical intervention,degrees of intra- and postoperative complications, and oncological and functional results. Results. In our series, RALP was performed without preserving neurovascular bundles or by using a nerve-sparing procedure in 66 (82.5% and 14 (17.5%, respectively; 22 (27.5% patients underwent lymphadenectomy. The average length of hospital stay was 7 (4–21 days; the mean time of urethral catheter removal was 10 (6–21 days postoperatively. The mean time of surgical intervention was 174 (121–276 min. Mean blood loss was 248 (35–1950 ml. Postmortem study revealed a positive surgical margin in 19 (24% cases and tumor invasion into the seminal vesicles in 5 (6% patients. Stages pT2 and pT3 were found in 56 (70% and 24 (30%, respectively; total Gleason scores were 6 (3+3, 7 (3+4, 7 (4+3, 8 (4+4 in 38 (47.5%, 35 (43.75%, 5 (6.25%, and 2 (2.5% patients, respectively. Among 34 patients examined 3 months after RALP, 28 (82.4% patients completely retained urine; 5 (14.7% applied not more than a pad a day. In patients with preserved erectile function, the

  20. Surgical Treatment for Achalasia of the Esophagus: Laparoscopic Heller Myotomy

    Science.gov (United States)

    Torres-Villalobos, Gonzalo; Martin-del-Campo, Luis Alfonso

    2013-01-01

    Achalasia is an esophageal motility disorder that leads to dysphagia, chest pain, and weight loss. Its diagnosis is clinically suspected and is confirmed with esophageal manometry. Although pneumatic dilation has a role in the treatment of patients with achalasia, laparoscopic Heller myotomy is considered by many experts as the best treatment modality for most patients with newly diagnosed achalasia. This review will focus on the surgical treatment of achalasia, with special emphasis on laparoscopic Heller myotomy. We will also present a brief discussion of the evaluation of patients with persistent or recurrent symptoms after surgical treatment for achalasia and emerging technologies such as LESS, robot-assisted myotomy, and POEM. PMID:24348542

  1. Surgical Treatment for Achalasia of the Esophagus: Laparoscopic Heller Myotomy

    Directory of Open Access Journals (Sweden)

    Gonzalo Torres-Villalobos

    2013-01-01

    Full Text Available Achalasia is an esophageal motility disorder that leads to dysphagia, chest pain, and weight loss. Its diagnosis is clinically suspected and is confirmed with esophageal manometry. Although pneumatic dilation has a role in the treatment of patients with achalasia, laparoscopic Heller myotomy is considered by many experts as the best treatment modality for most patients with newly diagnosed achalasia. This review will focus on the surgical treatment of achalasia, with special emphasis on laparoscopic Heller myotomy. We will also present a brief discussion of the evaluation of patients with persistent or recurrent symptoms after surgical treatment for achalasia and emerging technologies such as LESS, robot-assisted myotomy, and POEM.

  2. Analysis of reaching movements of upper arm in robot assisted exercises. Kinematic assessment of robot assisted upper arm reaching single-joint movements.

    Science.gov (United States)

    Iuppariello, Luigi; D'Addio, Giovanni; Romano, Maria; Bifulco, Paolo; Lanzillo, Bernardo; Pappone, Nicola; Cesarelli, Mario

    2016-01-01

    Robot-mediated therapy (RMT) has been a very dynamic area of research in recent years. Robotics devices are in fact capable to quantify the performances of a rehabilitation task in treatments of several disorders of the arm and the shoulder of various central and peripheral etiology. Different systems for robot-aided neuro-rehabilitation are available for upper limb rehabilitation but the biomechanical parameters proposed until today, to evaluate the quality of the movement, are related to the specific robot used and to the type of exercise performed. Besides, none study indicated a standardized quantitative evaluation of robot assisted upper arm reaching movements, so the RMT is still far to be considered a standardised tool. In this paper a quantitative kinematic assessment of robot assisted upper arm reaching movements, considering also the effect of gravity on the quality of the movements, is proposed. We studied a group of 10 healthy subjects and results indicate that our advised protocol can be useful for characterising normal pattern in reaching movements.

  3. Lower Limb Voluntary Movement Improvement Following a Robot-Assisted Locomotor Training in Spinal Cord Injury

    Directory of Open Access Journals (Sweden)

    Mirbagheri Mehdi

    2011-12-01

    Full Text Available Individuals with spinal cord injury (SCI suffer from severe impairments in voluntary movements. Literature reports a reduction in major kinematic and kinetic parameters of lower limbs’ joints. A body weight support treadmill training with robotic assistance has been widely used to improve lower-extremity function and locomotion in persons with SCI. Our objective was to explore the effects of 4-weeks robot-assisted locomotor training on voluntary movement of the ankle musculature in patients with incomplete SCI. In particular, we aimed to characterize the therapeutic effects of Lokomat training on kinematic measures (range of motion, velocity, smoothness during a dorsiflexion movement. We hypothesized that training would improve these measures. Preliminary results show an improvement of kinematic parameters during ankle dorsiflexion voluntary movement after a 4-weeks training in the major part of our participants. Complementary investigations are in progress to confirm these results and understand underlying mechanisms associated with the recovery.

  4. 3D force control for robotic-assisted beating heart surgery based on viscoelastic tissue model.

    Science.gov (United States)

    Liu, Chao; Moreira, Pedro; Zemiti, Nabil; Poignet, Philippe

    2011-01-01

    Current cardiac surgery faces the challenging problem of heart beating motion even with the help of mechanical stabilizer which makes delicate operation on the heart surface difficult. Motion compensation methods for robotic-assisted beating heart surgery have been proposed recently in literature, but research on force control for such kind of surgery has hardly been reported. Moreover, the viscoelasticity property of the interaction between organ tissue and robotic instrument further complicates the force control design which is much easier in other applications by assuming the interaction model to be elastic (industry, stiff object manipulation, etc.). In this work, we present a three-dimensional force control method for robotic-assisted beating heart surgery taking into consideration of the viscoelastic interaction property. Performance studies based on our D2M2 robot and 3D heart beating motion information obtained through Da Vinci™ system are provided.

  5. Laparoscopic versus robotic surgery for hepatocellular carcinoma: the first 46 consecutive cases.

    Science.gov (United States)

    Magistri, Paolo; Tarantino, Giuseppe; Guidetti, Cristiano; Assirati, Giacomo; Olivieri, Tiziana; Ballarin, Roberto; Coratti, Andrea; Di Benedetto, Fabrizio

    2017-09-01

    Hepatocellular carcinoma has a growing incidence worldwide, and represents a leading cause of death in patients with cirrhosis. Nowadays, minimally invasive approaches are spreading in every field of surgery and in liver surgery as well. We retrospectively reviewed demographics, clinical, and pathologic characteristics and short-term outcomes of patients who had undergone minimally invasive resections for hepatocellular carcinoma at our institution between June 2012 and May 2016. No significant differences in demographics and comorbidities were found between patients in the laparoscopic (n = 24) and robotic (n = 22) groups, except for the rates of cirrhotic patients (91.7% and 68.2%, respectively, P = 0.046). Perioperative data analysis showed that the operative time (mean, 211 and 318 min, respectively, P robotic-assisted resections were related to less Clavien I-II postoperative complications (22 cases versus 13 cases; P = 0.03). As regards resection margins, the two groups were similar with no statistically significant differences in rates of disease-free resection margins. A modern hepatobiliary center should offer both open and minimally invasive approaches to liver disease to provide the best care for each patient, according to the individual comorbidities, risk factors, and personal quality of life expectations. Our results show that the robotic approach is a reliable tool for accurate oncologic surgery, comparable to the laparoscopic approach. Robotic surgery also allows the surgeon to safely approach liver segments that are difficult to resect in laparoscopy, namely segments I-VII-VIII. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. A laser unit for photodynamic therapy and robot-assisted microsurgery in dentistry

    Science.gov (United States)

    Chunikhin, A. A.; Bazikyan, E. A.; Pikhtin, N. A.

    2017-06-01

    Results are presented of photochemical experiments with an IR-laser unit for microsurgery and photodynamic therapy in dentistry. The efficiency of direct generation of singlet oxygen in model organic media in the continuous-wave and pulsed nanosecond modes is examined. The unit can serve both as an independent instrument and as a part of a complex for robot-assisted surgery and dentistry.

  7. How robotic-assisted surgery can decrease the risk of mucosal tear during Heller myotomy procedure?

    Science.gov (United States)

    Ballouhey, Quentin; Dib, Nabil; Binet, Aurélien; Carcauzon-Couvrat, Véronique; Clermidi, Pauline; Longis, Bernard; Lardy, Hubert; Languepin, Jane; Cros, Jérôme; Fourcade, Laurent

    2017-06-01

    We report the first description of robotic-assisted Heller myotomy in children. The purpose of this study was to improve the safety of Heller myotomy by demonstrating, in two adolescent patients, the contribution of the robot to the different steps of this procedure. Due to the robot's freedom of movement and three-dimensional vision, there was an improvement in the accuracy, a gain in the safety regarding different key-points, decreasing the risk of mucosal perforation associated with this procedure.

  8. Gait performance and foot pressure distribution during wearable robot-assisted gait in elderly adults.

    Science.gov (United States)

    Lee, Su-Hyun; Lee, Hwang-Jae; Chang, Won Hyuk; Choi, Byung-Ok; Lee, Jusuk; Kim, Jeonghun; Ryu, Gyu-Ha; Kim, Yun-Hee

    2017-11-28

    A robotic exoskeleton device is an intelligent system designed to improve gait performance and quality of life for the wearer. Robotic technology has developed rapidly in recent years, and several robot-assisted gait devices were developed to enhance gait function and activities of daily living in elderly adults and patients with gait disorders. In this study, we investigated the effects of the Gait-enhancing Mechatronic System (GEMS), a new wearable robotic hip-assist device developed by Samsung Electronics Co, Ltd., Korea, on gait performance and foot pressure distribution in elderly adults. Thirty elderly adults who had no neurological or musculoskeletal abnormalities affecting gait participated in this study. A three-dimensional (3D) motion capture system, surface electromyography and the F-Scan system were used to collect data on spatiotemporal gait parameters, muscle activity and foot pressure distribution under three conditions: free gait without robot assistance (FG), robot-assisted gait with zero torque (RAG-Z) and robot-assisted gait (RAG). We found increased gait speed, cadence, stride length and single support time in the RAG condition. Reduced rectus femoris and medial gastrocnemius muscle activity throughout the terminal stance phase and reduced effort of the medial gastrocnemius muscle throughout the pre-swing phase were also observed in the RAG condition. In addition, walking with the assistance of GEMS resulted in a significant increase in foot pressure distribution, specifically in maximum force and peak pressure of the total foot, medial masks, anterior masks and posterior masks. The results of the present study reveal that GEMS may present an alternative way of restoring age-related changes in gait such as gait instability with muscle weakness, reduced step force and lower foot pressure in elderly adults. In addition, GEMS improved gait performance by improving push-off power and walking speed and reducing muscle activity in the lower

  9. Ankle voluntary movement enhancement following robotic-assisted locomotor training in spinal cord injury

    OpenAIRE

    Varoqui, Deborah; Niu, Xun; Mirbagheri, Mehdi M

    2014-01-01

    Background In incomplete spinal cord injury (iSCI), sensorimotor impairments result in severe limitations to ambulation. To improve walking capacity, physical therapies using robotic-assisted locomotor devices, such as the Lokomat, have been developed. Following locomotor training, an improvement in gait capabilities—characterized by increases in the over-ground walking speed and endurance—is generally observed in patients. To better understand the mechanisms underlying these improvements, we...

  10. Robotic-assisted transperitoneal radical prostatectomy in a patient with pelvic kidney

    International Nuclear Information System (INIS)

    Rabah, Danny M.; Alyami, Fahad A.

    2008-01-01

    Robots are increasingly utilized in urology, due to their favorable performance characteristics especially in prostatectomy and pyeloplasty. However, preoperative diagnosis of urogenital congenital anomalies and preoperative planning are important aspects to be considered. The presence of ectopic pelvic kidney is a challenge for the surgeon to perform robotic-assisted radical prostatectomy (RARP) without injury to the pelvic kidney (PC) or its blood supply. We report our experience of performing RARP in a patient with a PK. (author)

  11. Development of on the machine process monitoring and control strategy in Robot Assisted Polishing

    DEFF Research Database (Denmark)

    Pilny, Lukas; Bissacco, Giuliano

    2015-01-01

    Robot Assisted Polishing (RAP) can be used to polish rotational symmetric and free form components achieving surface roughness down to Sa 10 nm. With the aim to enable unmanned robust and cost efficient application of RAP, this paper presents the development of a monitoring and control strategy....... The multisensory approach was experimentally validated in polishing with bonded abrasives demonstrating its suitability for process control in RAP....

  12. Transoral robotic-assisted laryngeal cleft repair in the pediatric patient.

    Science.gov (United States)

    Leonardis, Rachel L; Duvvuri, Umamaheswar; Mehta, Deepak

    2014-09-01

    To assess the feasibility of performing robotic-assisted laryngeal cleft repair in the pediatric population. Retrospective chart review at a tertiary academic children's hospital. All patients underwent transoral robotic-assisted laryngeal cleft repair from March 2011 to June 2013. Demographics, robotic docking time, operative time, and postoperative course and swallowing function were collected and analyzed. Five children, three male and two female, underwent successful transoral robotic-assisted laryngeal cleft repair for closure of a type I laryngeal cleft. Mean age at time of surgery was 21.6 months (standard deviation 6.1 months; range, 15-29 months). From case 1 to case 5, robotic docking time (18-10 minutes), robotic operative time (102-36 minutes), and total operating room time (173-105 minutes) decreased. There were no complications with time until extubation (range, 2-3 days), length of intensive care unit stay (range, 3-4 days), and total hospital stay (range, 3-5 days) within acceptable range following laryngeal cleft repair. Modified barium swallow (two patients) or fiberoptic endoscopic evaluation of swallowing (three patients) was performed postoperatively, with all patients showing complete resolution of penetration and aspiration. In addition, all patients experienced subjective resolution of dysphagia and/or choking with feeds postoperatively. Transoral robotic-assisted laryngeal cleft repair may offer specific advantages over a traditional endoscopic approach. In our experience, the procedure was well tolerated and associated with definitive surgical cure in all patients. The scope of robotic technology continually expands and should be considered a feasible tool at an institution-based level. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  13. Human-Robot Interaction: Does Robotic Guidance Force Affect Gait-Related Brain Dynamics during Robot-Assisted Treadmill Walking?

    Directory of Open Access Journals (Sweden)

    Kristel Knaepen

    Full Text Available In order to determine optimal training parameters for robot-assisted treadmill walking, it is essential to understand how a robotic device interacts with its wearer, and thus, how parameter settings of the device affect locomotor control. The aim of this study was to assess the effect of different levels of guidance force during robot-assisted treadmill walking on cortical activity. Eighteen healthy subjects walked at 2 km.h-1 on a treadmill with and without assistance of the Lokomat robotic gait orthosis. Event-related spectral perturbations and changes in power spectral density were investigated during unassisted treadmill walking as well as during robot-assisted treadmill walking at 30%, 60% and 100% guidance force (with 0% body weight support. Clustering of independent components revealed three clusters of activity in the sensorimotor cortex during treadmill walking and robot-assisted treadmill walking in healthy subjects. These clusters demonstrated gait-related spectral modulations in the mu, beta and low gamma bands over the sensorimotor cortex related to specific phases of the gait cycle. Moreover, mu and beta rhythms were suppressed in the right primary sensory cortex during treadmill walking compared to robot-assisted treadmill walking with 100% guidance force, indicating significantly larger involvement of the sensorimotor area during treadmill walking compared to robot-assisted treadmill walking. Only marginal differences in the spectral power of the mu, beta and low gamma bands could be identified between robot-assisted treadmill walking with different levels of guidance force. From these results it can be concluded that a high level of guidance force (i.e., 100% guidance force and thus a less active participation during locomotion should be avoided during robot-assisted treadmill walking. This will optimize the involvement of the sensorimotor cortex which is known to be crucial for motor learning.

  14. Human-Robot Interaction: Does Robotic Guidance Force Affect Gait-Related Brain Dynamics during Robot-Assisted Treadmill Walking?

    Science.gov (United States)

    Knaepen, Kristel; Mierau, Andreas; Swinnen, Eva; Fernandez Tellez, Helio; Michielsen, Marc; Kerckhofs, Eric; Lefeber, Dirk; Meeusen, Romain

    2015-01-01

    In order to determine optimal training parameters for robot-assisted treadmill walking, it is essential to understand how a robotic device interacts with its wearer, and thus, how parameter settings of the device affect locomotor control. The aim of this study was to assess the effect of different levels of guidance force during robot-assisted treadmill walking on cortical activity. Eighteen healthy subjects walked at 2 km.h-1 on a treadmill with and without assistance of the Lokomat robotic gait orthosis. Event-related spectral perturbations and changes in power spectral density were investigated during unassisted treadmill walking as well as during robot-assisted treadmill walking at 30%, 60% and 100% guidance force (with 0% body weight support). Clustering of independent components revealed three clusters of activity in the sensorimotor cortex during treadmill walking and robot-assisted treadmill walking in healthy subjects. These clusters demonstrated gait-related spectral modulations in the mu, beta and low gamma bands over the sensorimotor cortex related to specific phases of the gait cycle. Moreover, mu and beta rhythms were suppressed in the right primary sensory cortex during treadmill walking compared to robot-assisted treadmill walking with 100% guidance force, indicating significantly larger involvement of the sensorimotor area during treadmill walking compared to robot-assisted treadmill walking. Only marginal differences in the spectral power of the mu, beta and low gamma bands could be identified between robot-assisted treadmill walking with different levels of guidance force. From these results it can be concluded that a high level of guidance force (i.e., 100% guidance force) and thus a less active participation during locomotion should be avoided during robot-assisted treadmill walking. This will optimize the involvement of the sensorimotor cortex which is known to be crucial for motor learning.

  15. Evolution of upper limb kinematics four years after subacute robot-assisted rehabilitation in stroke patients.

    Science.gov (United States)

    Pila, Ophélie; Duret, Christophe; Gracies, Jean-Michel; Francisco, Gerard E; Bayle, Nicolas; Hutin, Émilie

    2018-04-25

    To assess functional status and robot-based kinematic measures four years after subacute robot-assisted rehabilitation in hemiparesis. Twenty-two patients with stroke-induced hemiparesis underwent a ≥3-month upper limb combined program of robot-assisted and occupational therapy from two months post-stroke, and received community-based therapy after discharge. Four years later, 19 (86%) participated in this follow-up study. Assessments 2, 5 and 54 months post-stroke included Fugl-Meyer (FM), Modified Frenchay Scale (MFS, at Month 54) and robot-based kinematic measures of targeting tasks in three directions, north, paretic and non-paretic: distance covered, velocity, accuracy (root mean square (RMS) error from straight line) and smoothness (number of velocity peaks; upward changes in accuracy and smoothness represent worsening). Analysis was stratified by FM score at two months: ≥17 (Group 1) or Kinematic changes (three directions pooled) were: distance -1[-17;2]% (ns); velocity, -8[-32;28]% (ns); accuracy, +6[-13;98]% (ns); smoothness, +44[-6;126]% (p robot-assisted upper limb training during subacute post-stroke phase, movement kinematics deteriorated despite community-based therapy, especially in more severely impaired patients. EudraCT 2016-005121-36. Registration: 2016-12-20. Date of enrolment of the first participant to the trial: 2009-11-24.

  16. Body weight support during robot-assisted walking: influence on the trunk and pelvis kinematics.

    Science.gov (United States)

    Swinnen, Eva; Baeyens, Jean-Pierre; Hens, Gerrit; Knaepen, Kristel; Beckwée, David; Michielsen, Marc; Clijsen, Ron; Kerckhofs, Eric

    2015-01-01

    Efficacy studies concerning robot assisted gait rehabilitation showed limited clinical benefits. A changed kinematic pattern might be responsible for this. Little is known about the kinematics of the trunk and pelvis during robot assisted treadmill walking (RATW). The aim of this study was to assess the trunk and pelvis kinematics of healthy subjects during RATW, with different amounts of body weight support (BWS) compared to regular treadmill walking (TW). Eighteen healthy participants walked on a treadmill, while kinematics were registered by an electromagnetic tracking device. Hereafter, the kinematics of pelvis and trunk were registered during RATW (guidance force 30%) with 0%, 30% and 50% BWS. Compared to TW, RATW showed a decrease in the following trunk movements: axial rotation, anteroposterior flexion, lateral and anteroposterior translation. Besides, a decrease in lateral tilting and all translation of the pelvis was found when comparing RATW with TW. Furthermore, the anteroposterior tilting of the pelvis increased during RATW. In general, there was a decrease in trunk and pelvis movement amplitude during RATW compared with regular TW. Though, it is not known if these changes are responsible for the limited efficacy of robot assisted gait rehabilitation. Further research is indicated.

  17. Robotic-assisted transoral removal of a bilateral floor of mouth ranulas

    Directory of Open Access Journals (Sweden)

    Stromeyer Frederick W

    2011-07-01

    Full Text Available Abstract Objective To describe the management of bilateral oral ranulas with the use of the da Vinci Si Surgical System and discuss advantages and disadvantages over traditional transoral resection. Study Design Case Report and Review of Literature. Results A 47 year old woman presented to our service with an obvious right floor of mouth swelling. Clinical evaluation and computerized tomography scan confirmed a large floor of mouth ranula on the right and an incidental asymptomatic early ranula of the left sublingual gland. After obtaining an informed consent, the patient underwent a right transoral robotic-assisted transoral excision of the ranula and sublingual gland with identification and dissection of the submandibular duct and lingual nerve. The patient had an excellent outcome with no evidence of lingual nerve paresis and a return to oral intake on the first postoperative day. Subsequently, the patient underwent an elective transoral robotic-assisted excision of the incidental ranula on the left sublingual gland. Conclusion We describe the first robotic-assisted excision of bilateral oral ranulas in current literature. The use of the da Vinci system provides excellent visualization, magnification, and dexterity for transoral surgical management of ranulas with preservation of the lingual nerve and Wharton's duct with good functional outcomes. However, the use of the robotic system for anterior floor of mouth surgery in terms of improved surgical outcomes as compared to traditional transoral surgery, long-term recurrence rates, and cost effectiveness needs further validation.

  18. Initial experience with the new da Vinci single-port robot-assisted platform.

    Science.gov (United States)

    Ballestero Diego, R; Zubillaga Guerrero, S; Truan Cacho, D; Carrion Ballardo, C; Velilla Diez, G; Calleja Hermosa, P; Gutiérrez Baños, J L

    2017-06-01

    To describe our experience in the first cases of urological surgeries performed with the da Vinci single-port robot-assisted platform. We performed 5 single-port robot-assisted surgeries (R-LESS) between May and October 2014. We performed 3 ureteral reimplant surgeries, one ureteropyeloplasty in an inverted kidney and 1 partial nephrectomy. The perioperative and postoperative results were collected, as well as a report of the complications according to the Clavien classification system. Of the 5 procedures, 4 were performed completely by LESS, while 1 procedure was reconverted to multiport robot-assisted surgery. There were no intraoperative complications. We observed perioperative complications in 4 patients, all of which were grade 1 or 2. The mean surgical time was 262minutes (range, 230-300). In our initial experience with the da Vinci device, R-LESS surgery was feasible and safe. There are still a number of limitations in its use, which require new and improved R-LESS platforms. Copyright © 2016 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  19. Slow Versus Fast Robot-Assisted Locomotor Training After Severe Stroke: A Randomized Controlled Trial.

    Science.gov (United States)

    Rodrigues, Thais Amanda; Goroso, Daniel Gustavo; Westgate, Philip M; Carrico, Cheryl; Batistella, Linamara R; Sawaki, Lumy

    2017-10-01

    Robot-assisted locomotor training on a bodyweight-supported treadmill is a rehabilitation intervention that compels repetitive practice of gait movements. Standard treadmill speed may elicit rhythmic movements generated primarily by spinal circuits. Slower-than-standard treadmill speed may elicit discrete movements, which are more complex than rhythmic movements and involve cortical areas. Compare effects of fast (i.e., rhythmic) versus slow (i.e., discrete) robot-assisted locomotor training on a bodyweight-supported treadmill in subjects with chronic, severe gait deficit after stroke. Subjects (N = 18) were randomized to receive 30 sessions (5 d/wk) of either fast or slow robot-assisted locomotor training on a bodyweight-supported treadmill in an inpatient setting. Functional ambulation category, time up and go, 6-min walk test, 10-m walk test, Berg Balance Scale, and Fugl-Meyer Assessment were administered at baseline and postintervention. The slow group had statistically significant improvement on functional ambulation category (first quartile-third quartile, P = 0.004), 6-min walk test (95% confidence interval [CI] = 1.8 to 49.0, P = 0.040), Berg Balance Scale (95% CI = 7.4 to 14.8, P locomotor training on a bodyweight-supported treadmill after severe stroke, slow training targeting discrete movement may yield greater benefit than fast training.

  20. The role of visual and direct force feedback in robotics-assisted mitral valve annuloplasty.

    Science.gov (United States)

    Currie, Maria E; Talasaz, Ali; Rayman, Reiza; Chu, Michael W A; Kiaii, Bob; Peters, Terry; Trejos, Ana Luisa; Patel, Rajni

    2017-09-01

    The objective of this work was to determine the effect of both direct force feedback and visual force feedback on the amount of force applied to mitral valve tissue during ex vivo robotics-assisted mitral valve annuloplasty. A force feedback-enabled master-slave surgical system was developed to provide both visual and direct force feedback during robotics-assisted cardiac surgery. This system measured the amount of force applied by novice and expert surgeons to cardiac tissue during ex vivo mitral valve annuloplasty repair. The addition of visual (2.16 ± 1.67), direct (1.62 ± 0.86), or both visual and direct force feedback (2.15 ± 1.08) resulted in lower mean maximum force applied to mitral valve tissue while suturing compared with no force feedback (3.34 ± 1.93 N; P forces on cardiac tissue during robotics-assisted mitral valve annuloplasty suturing, force feedback may be required. Copyright © 2016 John Wiley & Sons, Ltd.

  1. Serum vaspin level as a predictive indicator in the amelioration of fatty liver and metabolic disturbance in patients with severe obesity after laparoscopic vertical banded gastroplasty.

    Science.gov (United States)

    Wang, Yong; Yu, Zong-Fan; Cheng, Yun-Sheng; Jia, Ben-Li; Yu, Gang; Yin, Xiao-Qiang; Wang, Yang

    2017-07-01

    This study is all about predicting the value of serum vaspin level in the amelioration of fatty liver and metabolic disturbance in patients with severe obesity after laparoscopic vertical banded gastroplasty (LVBG). A total of 164 patients (from January 2012 to May 2015) with severe obesity were chosen and performed LVBG. Enzyme-linked immunosorbent assay was performed to detect the serum vaspin level. The patients were given a biochemical automatic analyzer to measure the biochemical indicators. Homeostasis model assessment (HOMA) helps in the calculation of fasting insulin level (FINS) and insulin resistance (IR). The changes in fatty liver were examined by computed tomography (CT). Receiver operating characteristic curve is used to increase the predictive value of serum vaspin level in the amelioration of liver function and disturbances in the metabolism. Weight, BMI, waist circumference, serum vaspin level, and triglyceride (TG) decreased, but CT value of liver increased at 4th, 7th, and 12th month after surgery. After the 7th and 12th month period of surgery, the alanine aminotransferase, aspartate aminotransferase, FINS, and HOMA-IR reduced in the patients (P fatty liver and metabolic disturbance. This study proves that the serum vaspin level serves as a predictive indicator in the amelioration of fatty liver and metabolic disturbance in patients with severe obesity after LVBG.

  2. 3D visualization reduces operating time when compared to high-definition 2D in laparoscopic liver resection: a case-matched study.

    Science.gov (United States)

    Velayutham, Vimalraj; Fuks, David; Nomi, Takeo; Kawaguchi, Yoshikuni; Gayet, Brice

    2016-01-01

    To evaluate the effect of three-dimensional (3D) visualization on operative performance during elective laparoscopic liver resection (LLR). Major limitations of conventional laparoscopy are lack of depth perception and tactile feedback. Introduction of robotic technology, which employs 3D imaging, has removed only one of these technical obstacles. Despite the significant advantages claimed, 3D systems have not been widely accepted. In this single institutional study, 20 patients undergoing LLR by high-definition 3D laparoscope between April 2014 and August 2014 were matched to a retrospective control group of patients who underwent LLR by two-dimensional (2D) laparoscope. The number of patients who underwent major liver resection was 5 (25%) in the 3D group and 10 (25%) in the 2D group. There was no significant difference in contralateral wedge resection or combined resections between the 3D and 2D groups. There was no difference in the proportion of patients undergoing previous abdominal surgery (70 vs. 77%, p = 0.523) or previous hepatectomy (20 vs. 27.5%, p = 0.75). The operative time was significantly shorter in the 3D group when compared to 2D (225 ± 109 vs. 284 ± 71 min, p = 0.03). There was no significant difference in blood loss in the 3D group when compared to 2D group (204 ± 226 in 3D vs. 252 ± 349 ml in 2D group, p = 0.291). The major complication rates were similar, 5% (1/20) and 7.5% (3/40), respectively, (p ≥ 0.99). 3D visualization may reduce the operating time compared to high-definition 2D. Further large studies, preferably prospective randomized control trials are required to confirm this.

  3. Robotic distal pancreatectomy versus conventional laparoscopic distal pancreatectomy: a comparative study for short-term outcomes.

    Science.gov (United States)

    Lai, Eric C H; Tang, Chung Ngai

    2015-09-01

    Robotic system has been increasingly used in pancreatectomy. However, the effectiveness of this method remains uncertain. This study compared the surgical outcomes between robot-assisted laparoscopic distal pancreatectomy and conventional laparoscopic distal pancreatectomy. During a 15-year period, 35 patients underwent minimally invasive approach of distal pancreatectomy in our center. Seventeen of these patients had robot-assisted laparoscopic approach, and the remaining 18 had conventional laparoscopic approach. Their operative parameters and perioperative outcomes were analyzed retrospectively in a prospective database. The mean operating time in the robotic group (221.4 min) was significantly longer than that in the laparoscopic group (173.6 min) (P = 0.026). Both robotic and conventional laparoscopic groups presented no significant difference in spleen-preservation rate (52.9% vs. 38.9%) (P = 0.505), operative blood loss (100.3 ml vs. 268.3 ml) (P = 0.29), overall morbidity rate (47.1% vs. 38.9%) (P = 0.73), and post-operative hospital stay (11.4 days vs. 14.2 days) (P = 0.46). Both groups also showed no perioperative mortality. Similar outcomes were observed in robotic distal pancreatectomy and conventional laparoscopic approach. However, robotic approach tended to have the advantages of less blood loss and shorter hospital stay. Further studies are necessary to determine the clinical position of robotic distal pancreatectomy.

  4. Effect of Regional Hospital Competition and Hospital Financial Status on the Use of Robotic-Assisted Surgery.

    Science.gov (United States)

    Wright, Jason D; Tergas, Ana I; Hou, June Y; Burke, William M; Chen, Ling; Hu, Jim C; Neugut, Alfred I; Ananth, Cande V; Hershman, Dawn L

    2016-07-01

    Despite the lack of efficacy data, robotic-assisted surgery has diffused rapidly into practice. Marketing to physicians, hospitals, and patients has been widespread, but how this marketing has contributed to the diffusion of the technology remains unknown. To examine the effect of regional hospital competition and hospital financial status on the use of robotic-assisted surgery for 5 commonly performed procedures. A cohort study of 221 637 patients who underwent radical prostatectomy, total nephrectomy, partial nephrectomy, hysterectomy, or oophorectomy at 1370 hospitals in the United States from January 1, 2010, to December 31, 2011, was conducted. The association between hospital competition, hospital financial status, and performance of robotic-assisted surgery was examined. The association between hospital competition was measured with the Herfindahl-Hirschman Index (HHI), hospital financial status was estimated as operating margin, and performance of robotic-assisted surgery was examined using multivariate mixed-effects regression models. We identified 221 637 patients who underwent one of the procedures of interest. The cohort included 30 345 patients who underwent radical prostatectomy; 20 802, total nephrectomy; 8060, partial nephrectomy; 134 985, hysterectomy; and 27 445, oophorectomy. Robotic-assisted operations were performed for 20 500 (67.6%) radical prostatectomies, 1405 (6.8%) total nephrectomies, 2759 (34.2%) partial nephrectomies, 14 047 (10.4%) hysterectomies, and 1782 (6.5%) oophorectomies. Use of robotic-assisted surgery increased for each procedure from January 2010 through December 2011. For all 5 operations, increased market competition (as measured by the HHI) was associated with increased use of robotic-assisted surgery. For prostatectomy, the risk ratios (95% CIs) for undergoing a robotic-assisted procedure were 2.20 (1.50-3.24) at hospitals in moderately competitive markets and 2.64 (1.84-3.78) for highly competitive markets

  5. Robot-Assisted Middle Pancreatectomy for Elderly Patients: Our Initial Experience

    Science.gov (United States)

    Zhang, Tian; Wang, Xinjing; Huo, Zhen; Wen, Chenlei; Wu, Zhichong; Zhan, Qian; Jin, Jiabin; Cheng, Dongfeng; Chen, Hao; Deng, Xiaxing; Shen, Baiyong; Peng, Chenghong

    2015-01-01

    Background The aim of this study was to evaluate the indications, safety, feasibility, and short- and long-term outcomes for elderly patients who underwent robot-assisted middle pancreatectomies (MPs). Material/Methods Ten patients (≥60 years) underwent robot-assisted middle pancreatectomies from 2012 to 2015. The perioperative data, including tumor size, operating time, rate of postoperative pancreatic fistula (POPF), postoperative morbidity, and other parameters, were analyzed. We collected and analyzed the follow-up information. Results The mean age of patients was 64.30 years (range, 60–73 years). The average tumor size was 2.61 cm. The 10 cases were all benign or low-grade malignant lesions. The mean operating time was 175.00 min. The mean blood loss was 113.00 ml with no blood transfusion needed. Postoperative fistulas developed in 5 patients; there were 2 Grade A fistulas and 3 grade B fistulas. There were 3 patients who underwent postoperative complications, including 2 Grade 1 or 2 complications and 1 Grade 3 complication. No reoperation and postoperative mortality occurred. The mean hospital stay was 19.91 days. After a median follow-up of 23 months, new onset of diabetes mellitus developed in 1 patient and none suffered from deterioration of previously diagnosed diabetes or exocrine insufficiency, and no tumor recurrence happened. Conclusions Robot-assisted middle pancreatectomy was safe and feasible for elderly people. It had low risk of exocrine or endocrine dysfunction and benefited patients’ long-term outcomes. Incidence of POPF was relatively high but we could prevent it from resulting in bad outcomes by scientific perioperative care and systemic treatment. PMID:26395335

  6. Robot-assisted radical cystoprostatectomy: Analysis of the complications and oncological and functional aspects.

    Science.gov (United States)

    Kanashiro, A; Gaya, J M; Palou, J; Gausa, L; Villavicencio, H

    2017-05-01

    To review our experience in robot-assisted radical cystectomy, assessing the complications and oncological and functional results. From 2007 to 2014, we performed 67 robot-assisted radical cystectomies combined with lymphadenectomy in 61 cases. The operations were performed on 37 patients due to muscle-invasive tumours and on 30 due to high-risk nonmuscle-invasive tumours. Urinary diversion was conducted extracorporeally, using a Studer neobladder in 47 cases. The mean blood loss was 300mL. No case required conversion to open surgery. The median number of lymph nodes extracted was 16 (range 3-33). Pathology revealed 16 pT0, 15 pTis,-pT1-pTa and 44 muscle-invasive tumours, 8 pN+ and 1 with positive margins. The mean hospital stay was 9 days. With a median follow-up of 16 months, 9 (13%) patients were readmitted after the discharge, most for infections associated with the vesical catheter and other catheters. Forty patients (59.7%) presented complications (most were Clavien grade 1-2). There was recurrence during the follow-up in 4 cases (6%), and 4 (5.9%) patients died from cancer. Nineteen (28.3%) patients had complications after 30 days, most of which were urinary tract infections. Of the 47 patients with a neobladder, 45 (96%) had proper daytime continence and 42 (89%) had proper nighttime continence. Ninety percent and 64% of the patients with previously normal sexual function and reduced sexual function, respectively, were able to preserve sexual function with or without drug treatment. Robot-assisted radical cystectomy plus lymphadenectomy, with extracorporeal reconstruction of the urinary diversion, offers good oncological and functional results without increasing the number of complications. Copyright © 2016 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  7. Effect of Robot-Assisted Game Training on Upper Extremity Function in Stroke Patients

    Science.gov (United States)

    2017-01-01

    Objective To determine the effects of combining robot-assisted game training with conventional upper extremity rehabilitation training (RCT) on motor and daily functions in comparison with conventional upper extremity rehabilitation training (OCT) in stroke patients. Methods Subjects were eligible if they were able to perform the robot-assisted game training and were divided randomly into a RCT and an OCT group. The RCT group performed one daily session of 30 minutes of robot-assisted game training with a rehabilitation robot, plus one daily session of 30 minutes of conventional rehabilitation training, 5 days a week for 2 weeks. The OCT group performed two daily sessions of 30 minutes of conventional rehabilitation training. The effects of training were measured by a Manual Function Test (MFT), Manual Muscle Test (MMT), Korean version of the Modified Barthel Index (K-MBI) and a questionnaire about satisfaction with training. These measurements were taken before and after the 2-week training. Results Both groups contained 25 subjects. After training, both groups showed significant improvements in motor and daily functions measured by MFT, MMT, and K-MBI compared to the baseline. Both groups demonstrated similar training effects, except motor power of wrist flexion. Patients in the RCT group were more satisfied than those in the OCT group. Conclusion There were no significant differences in changes in most of the motor and daily functions between the two types of training. However, patients in the RCT group were more satisfied than those in the OCT group. Therefore, RCT could be a useful upper extremity rehabilitation training method. PMID:28971037

  8. Effect of Robot-Assisted Game Training on Upper Extremity Function in Stroke Patients.

    Science.gov (United States)

    Lee, Kyeong Woo; Kim, Sang Beom; Lee, Jong Hwa; Lee, Sook Joung; Kim, Jin Wan

    2017-08-01

    To determine the effects of combining robot-assisted game training with conventional upper extremity rehabilitation training (RCT) on motor and daily functions in comparison with conventional upper extremity rehabilitation training (OCT) in stroke patients. Subjects were eligible if they were able to perform the robot-assisted game training and were divided randomly into a RCT and an OCT group. The RCT group performed one daily session of 30 minutes of robot-assisted game training with a rehabilitation robot, plus one daily session of 30 minutes of conventional rehabilitation training, 5 days a week for 2 weeks. The OCT group performed two daily sessions of 30 minutes of conventional rehabilitation training. The effects of training were measured by a Manual Function Test (MFT), Manual Muscle Test (MMT), Korean version of the Modified Barthel Index (K-MBI) and a questionnaire about satisfaction with training. These measurements were taken before and after the 2-week training. Both groups contained 25 subjects. After training, both groups showed significant improvements in motor and daily functions measured by MFT, MMT, and K-MBI compared to the baseline. Both groups demonstrated similar training effects, except motor power of wrist flexion. Patients in the RCT group were more satisfied than those in the OCT group. There were no significant differences in changes in most of the motor and daily functions between the two types of training. However, patients in the RCT group were more satisfied than those in the OCT group. Therefore, RCT could be a useful upper extremity rehabilitation training method.

  9. Acoustic emission-based in-process monitoring of surface generation in robot-assisted polishing

    DEFF Research Database (Denmark)

    Pilny, Lukas; Bissacco, Giuliano; De Chiffre, Leonardo

    2016-01-01

    The applicability of acoustic emission (AE) measurements for in-process monitoring of surface generation in the robot-assisted polishing (RAP) was investigated. Surface roughness measurements require interruption of the process, proper surface cleaning and measurements that sometimes necessitate...... automatic detection of optimal process endpoint allow intelligent process control, creating fundamental elements in development of robust fully automated RAP process for its widespread industrial application....... removal of the part from the machine tool. In this study, stabilisation of surface roughness during polishing rotational symmetric surfaces by the RAP process was monitored by AE measurements. An AE sensor was placed on a polishing arm in direct contact with a bonded abrasive polishing tool...

  10. Complications and health-related quality of life after robot-assisted versus open radical cystectomy

    DEFF Research Database (Denmark)

    Lauridsen, Susanne Vahr; Tønnesen, Hanne; Jensen, Bente Thoft

    2017-01-01

    Background: Radical cystectomy is associated with high rates of perioperative morbidity. Robotic-assisted radical cystectomy (RARC) is widely used today despite limited evidence for clinical superiority. The aim of this review was to evaluate the effect of RARC compared to open radical cystectomy...... (ORC) on complications and secondary on length of stay, time back to work and health-related quality of life (HRQoL). Methods: The databases PubMed, The Cochrane Library, Embase and CINAHL were searched. A systematic review according to the PRISMA guidelines and cumulative analysis was conducted...

  11. Measuring the Latency of an Augmented Reality System for Robot-Assisted Minimally Invasive Surgery

    DEFF Research Database (Denmark)

    Jørgensen, Martin Kibsgaard; Kraus, Martin

    2017-01-01

    visual communication in training for robot-assisted minimally invasive surgery with da Vinci surgical systems. To make sure that our augmented reality system provides the best possible user experience, we investigated the video latency of the da Vinci surgical system and how the components of our system...... affect the overall latency. To measure the photon-to-photon latency, we used a microcontroller to determine the time between the activation of a lightemitting diode in front of the endoscopic camera and the corresponding increase in intensity of the surgeon's display as measured by a phototransistor...

  12. Coherent anti-Stokes Raman scattering rigid endoscope toward robot-assisted surgery.

    Science.gov (United States)

    Hirose, K; Aoki, T; Furukawa, T; Fukushima, S; Niioka, H; Deguchi, S; Hashimoto, M

    2018-02-01

    Label-free visualization of nerves and nervous plexuses will improve the preservation of neurological functions in nerve-sparing robot-assisted surgery. We have developed a coherent anti-Stokes Raman scattering (CARS) rigid endoscope to distinguish nerves from other tissues during surgery. The developed endoscope, which has a tube with a diameter of 12 mm and a length of 270 mm, achieved 0.91% image distortion and 8.6% non-uniformity of CARS intensity in the whole field of view (650 μm diameter). We demonstrated CARS imaging of a rat sciatic nerve and visualization of the fine structure of nerve fibers.

  13. Individualized robot-assisted training for MS- and stroke patients in I-TRAVLE

    Directory of Open Access Journals (Sweden)

    Bastiaens Hanne

    2011-12-01

    Full Text Available Persons with central nervous deficits, such as MS and stroke patients, can benefit a lot from suitable training approaches that enhance their ability to perform activities in daily life. Personalized training, in accordance with the individual capabilities of the patient is a key issue in this context. We propose several techniques for individualization, including adaptive training games. Evaluations with patients and therapists reveal appreciation for the resulting Individualized, Technology-supported and RobotAssisted Virtual Learning Environments (I-TRAVLE system.

  14. Investigating the Effects of Robot-Assisted Therapy among Children with Autism Spectrum Disorder using Bio-markers

    Science.gov (United States)

    Bharatharaj, Jaishankar; Huang, Loulin; Al-Jumaily, Ahmed; Elara, Mohan Rajesh; Krägeloh, Chris

    2017-09-01

    Therapeutic pet robots designed to help humans with various medical conditions could play a vital role in physiological, psychological and social-interaction interventions for children with autism spectrum disorder (ASD). In this paper, we report our findings from a robot-assisted therapeutic study conducted over seven weeks to investigate the changes in stress levels of children with ASD. For this study, we used the parrot-inspired therapeutic robot, KiliRo, we developed and investigated urinary and salivary samples of participating children to report changes in stress levels before and after interacting with the robot. This is a pioneering human-robot interaction study to investigate the effects of robot-assisted therapy using salivary samples. The results show that the bio-inspired robot-assisted therapy can significantly help reduce the stress levels of children with ASD.

  15. Facilitators and Barriers to Adopting Robotic-Assisted Surgery: Contextualizing the Unified Theory of Acceptance and Use of Technology

    Science.gov (United States)

    BenMessaoud, Christine; Kharrazi, Hadi; MacDorman, Karl F.

    2011-01-01

    Robotic-assisted surgical techniques are not yet well established among surgeon practice groups beyond a few surgical subspecialties. To help identify the facilitators and barriers to their adoption, this belief-elicitation study contextualized and supplemented constructs of the unified theory of acceptance and use of technology (UTAUT) in robotic-assisted surgery. Semi-structured individual interviews were conducted with 21 surgeons comprising two groups: users and nonusers. The main facilitators to adoption were Perceived Usefulness and Facilitating Conditions among both users and nonusers, followed by Attitude Toward Using Technology among users and Extrinsic Motivation among nonusers. The three main barriers to adoption for both users and nonusers were Perceived Ease of Use and Complexity, Perceived Usefulness, and Perceived Behavioral Control. This study's findings can assist surgeons, hospital and medical school administrators, and other policy makers on the proper adoption of robotic-assisted surgery and can guide future research on the development of theories and framing of hypotheses. PMID:21283719

  16. Kinematic modelling of a five-DOFs spatial manipulator used in robot-assisted surgery

    Directory of Open Access Journals (Sweden)

    Shakti Singh

    2016-09-01

    Full Text Available Since last three decades, research in the field of robot kinematics is boosted-up among different researchers worldwide. This is mainly due to their increased use in various challenging fields of engineering and science. One such challenging application is the use of master–slave concept in a robot-assisted surgery. The authors have already performed the kinematic study and gravity balancing of seven degrees-of-freedom (DOFs surgeon-side manipulator (Singh et al., 2015a, 2015b. To meet these challenging demands, the most important aspect of a robotic manipulator is to develop an accurate kinematic model. In this direction, different researchers in the literature have made significant contributions. Out of these, the most prominent one is D–H parameters method, which was proposed by Denavit and Hartenberg in 1955. In the present work, this method is applied to a five-DOFs spatial manipulator, named as patient-side manipulator, which tracks the motion of surgeon-side manipulator during a robot-assisted surgery. The prototype considered in this work is a spatial serial manipulator, being developed at CSIR-CSIO Chandigarh. Experimental validations are performed and results are found to be in close agreement.

  17. Upper limb robot-assisted therapy in cerebral palsy: a single-blind randomized controlled trial.

    Science.gov (United States)

    Gilliaux, Maxime; Renders, Anne; Dispa, Delphine; Holvoet, Dominique; Sapin, Julien; Dehez, Bruno; Detrembleur, Christine; Lejeune, Thierry M; Stoquart, Gaëtan

    2015-02-01

    Several pilot studies have evoked interest in robot-assisted therapy (RAT) in children with cerebral palsy (CP). To assess the effectiveness of RAT in children with CP through a single-blind randomized controlled trial. Sixteen children with CP were randomized into 2 groups. Eight children performed 5 conventional therapy sessions per week over 8 weeks (control group). Eight children completed 3 conventional therapy sessions and 2 robot-assisted sessions per week over 8 weeks (robotic group). For both groups, each therapy session lasted 45 minutes. Throughout each RAT session, the patient attempted to reach several targets consecutively with the REAPlan. The REAPlan is a distal effector robot that allows for displacements of the upper limb in the horizontal plane. A blinded assessment was performed before and after the intervention with respect to the International Classification of Functioning framework: body structure and function (upper limb kinematics, Box and Block test, Quality of Upper Extremity Skills Test, strength, and spasticity), activities (Abilhand-Kids, Pediatric Evaluation of Disability Inventory), and participation (Life Habits). During each RAT session, patients performed 744 movements on average with the REAPlan. Among the variables assessed, the smoothness of movement (P robotic group than in the control group. This single-blind randomized controlled trial provides the first evidence that RAT is effective in children with CP. Future studies should investigate the long-term effects of this therapy. © The Author(s) 2014.

  18. Reviewing effectiveness of ankle assessment techniques for use in robot-assisted therapy.

    Science.gov (United States)

    Zhang, Mingming; Davies, T Claire; Zhang, Yanxin; Xie, Shane

    2014-01-01

    This article provides a comprehensive review of studies that investigated ankle assessment techniques to better understand those that can be used in the real-time monitoring of rehabilitation progress for implementation in conjunction with robot-assisted therapy. Seventy-six publications published between January 1980 and August 2013 were selected based on eight databases. They were divided into two main categories (16 qualitative and 60 quantitative studies): 13 goniometer studies, 18 dynamometer studies, and 29 studies about innovative techniques. A total of 465 subjects participated in the 29 quantitative studies of innovative measurement techniques that may potentially be integrated in a real-time monitoring device, of which 19 studies included less than 10 participants. Results show that qualitative ankle assessment methods are not suitable for real-time monitoring in robot-assisted therapy, though they are reliable for certain patients, while the quantitative methods show great potential. The majority of quantitative techniques are reliable in measuring ankle kinematics and kinetics but are usually available only for use in the sagittal plane. Limited studies determine kinematics and kinetics in all three planes (sagittal, transverse, and frontal) where motions of the ankle joint and the subtalar joint actually occur.

  19. Robot-assisted motor activation monitored by time-domain optical brain imaging

    Science.gov (United States)

    Steinkellner, O.; Wabnitz, H.; Schmid, S.; Steingräber, R.; Schmidt, H.; Krüger, J.; Macdonald, R.

    2011-07-01

    Robot-assisted motor rehabilitation proved to be an effective supplement to conventional hand-to-hand therapy in stroke patients. In order to analyze and understand motor learning and performance during rehabilitation it is desirable to develop a monitor to provide objective measures of the corresponding brain activity at the rehabilitation progress. We used a portable time-domain near-infrared reflectometer to monitor the hemodynamic brain response to distal upper extremity activities. Four healthy volunteers performed two different robot-assisted wrist/forearm movements, flexion-extension and pronation-supination in comparison with an unassisted squeeze ball exercise. A special headgear with four optical measurement positions to include parts of the pre- and postcentral gyrus provided a good overlap with the expected activation areas. Data analysis based on variance of time-of-flight distributions of photons through tissue was chosen to provide a suitable representation of intracerebral signals. In all subjects several of the four detection channels showed a response. In some cases indications were found of differences in localization of the activated areas for the various tasks.

  20. Anticipation, Teamwork, and Cognitive Load: Chasing Efficiency during Robot-Assisted Surgery

    Science.gov (United States)

    Sexton, Kevin; Johnson, Amanda; Gotsch, Amanda; Hussein, Ahmed A.; Cavuoto, Lora; Guru, Khurshid A.

    2018-01-01

    Introduction Robot-assisted surgery (RAS) has changed the traditional operating room, occupying more space with equipment and isolating console surgeons away from the patients and their team. We aimed to evaluate how anticipation of surgical steps and familiarity between team members impacted efficiency and safety. Methods We analyzed recordings (video and audio) of 12 robot-assisted radical prostatectomies. Any requests between surgeon and the team members were documented and classified by personnel, equipment type, mode of communication, level of inconvenience in fulfilling the request, and anticipation. Surgical team members completed questionnaires assessing team familiarity and cognitive load (NASA-TLX). Predictors of team efficiency were assessed using Pearson correlation and stepwise linear regression. Results 1330 requests were documented of which 413 (31%) were anticipated. Anticipation correlated negatively with operative time resulting in overall 8% reduction of OR time. Team familiarity negatively correlated with inconveniences. Anticipation ratio, percent of requests that were nonverbal, and total request duration were significantly correlated with the console surgeons’ cognitive load (r=0.77, p=0.006; r=0.63, p=0.04; and r=0.70, p=0.02, respectively). Conclusions Anticipation and active engagement by the surgical team resulted in shorter operative time; and higher familiarity scores were associated with fewer inconveniences. Less anticipation and nonverbal requests were also associated with lower cognitive load for the console surgeon. Training efforts to increase anticipation and team familiarity can improve team efficiency during RAS. PMID:28689193

  1. Costs of Robotic-Assisted Versus Traditional Laparoscopy in Endometrial Cancer.

    Science.gov (United States)

    Vuorinen, Riikka-Liisa K; Mäenpää, Minna M; Nieminen, Kari; Tomás, Eija I; Luukkaala, Tiina H; Auvinen, Anssi; Mäenpää, Johanna U

    2017-10-01

    The purpose of this study was to compare the costs of traditional laparoscopy and robotic-assisted laparoscopy in the treatment of endometrial cancer. A total of 101 patients with endometrial cancer were randomized to the study and operated on starting from 2010 until 2013, at the Department of Obstetrics and Gynecology of Tampere University Hospital, Tampere, Finland. Costs were calculated based on internal accounting, hospital database, and purchase prices and were compared using intention-to-treat analysis. Main outcome measures were item costs and total costs related to the operation, including a 6-month postoperative follow-up. The total costs including late complications were 2160 &OV0556; higher in the robotic group (median for traditional 5823 &OV0556;, vs robot median 7983 &OV0556;, P costs for instruments and equipment as well as to more expensive operating room and postanesthesia care unit time. Traditional laparoscopy involved higher costs for operation personnel, general costs, medication used in the operation, and surgeon, although these costs were not substantial. There was no significant difference in in-patient stay, laboratory, radiology, blood products, or costs related to complications. According to this study, robotic-assisted laparoscopy is 37% more expensive than traditional laparoscopy in the treatment of endometrial cancer. The cost difference is mainly explained by amortization of the robot and its instrumentation.

  2. Robot-assisted endoscope guidance versus manual endoscope guidance in functional endonasal sinus surgery (FESS).

    Science.gov (United States)

    Eichhorn, Klaus Wolfgang; Westphal, Ralf; Rilk, Markus; Last, Carsten; Bootz, Friedrich; Wahl, Friedrich; Jakob, Mark; Send, Thorsten

    2017-10-01

    Having one hand occupied with the endoscope is the major disadvantage for the surgeon when it comes to functional endoscopic sinus surgery (FESS). Only the other hand is free to use the surgical instruments. Tiredness or frequent instrument changes can thus lead to shaky endoscopic images. We collected the pose data (position and orientation) of the rigid 0° endoscope and all the instruments used in 16 FESS procedures with manual endoscope guidance as well as robot-assisted endoscope guidance. In combination with the DICOM CT data, we tracked the endoscope poses and workspaces using self-developed tracking markers. All surgeries were performed once with the robot and once with the surgeon holding the endoscope. Looking at the durations required, we observed a decrease in the operating time because one surgeon doing all the procedures and so a learning curve occurred what we expected. The visual inspection of the specimens showed no damages to any of the structures outside the paranasal sinuses. Robot-assisted endoscope guidance in sinus surgery is possible. Further CT data, however, are desirable for the surgical analysis of a tracker-based navigation within the anatomic borders. Our marker-based tracking of the endoscope as well as the instruments makes an automated endoscope guidance feasible. On the subjective side, we see that RASS brings a relief for the surgeon.

  3. Ambulatory movements, team dynamics and interactions during robot-assisted surgery.

    Science.gov (United States)

    Ahmad, Nabeeha; Hussein, Ahmed A; Cavuoto, Lora; Sharif, Mohamed; Allers, Jenna C; Hinata, Nobuyuki; Ahmad, Basel; Kozlowski, Justen D; Hashmi, Zishan; Bisantz, Ann; Guru, Khurshid A

    2016-07-01

    To analyse ambulatory movements and team dynamics during robot-assisted surgery (RAS), and to investigate whether congestion of the physical space associated with robotic technology led to workflow challenges or predisposed to errors and adverse events. With institutional review board approval, we retrospectively reviewed 10 recorded robot-assisted radical prostatectomies in a single operating room (OR). The OR was divided into eight zones, and all movements were tracked and described in terms of start and end zones, duration, personnel and purpose. Movements were further classified into avoidable (can be eliminated/improved) and unavoidable (necessary for completion of the procedure). The mean operating time was 166 min, of which ambulation constituted 27 min (16%). A total of 2 896 ambulatory movements were identified (mean: 290 ambulatory movements/procedure). Most of the movements were procedure-related (31%), and were performed by the circulating nurse. We identified 11 main pathways in the OR; the heaviest traffic was between the circulating nurse zone, transit zone and supply-1 zone. A total of 50% of ambulatory movements were found to be avoidable. More than half of the movements during RAS can be eliminated with an improved OR setting. More studies are needed to design an evidence-based OR layout that enhances access, workflow and patient safety. © 2016 The Authors BJU International © 2016 BJU International Published by John Wiley & Sons Ltd.

  4. Endoscopic vision-based tracking of multiple surgical instruments during robot-assisted surgery.

    Science.gov (United States)

    Ryu, Jiwon; Choi, Jaesoon; Kim, Hee Chan

    2013-01-01

    Robot-assisted minimally invasive surgery is effective for operations in limited space. Enhancing safety based on automatic tracking of surgical instrument position to prevent inadvertent harmful events such as tissue perforation or instrument collisions could be a meaningful augmentation to current robotic surgical systems. A vision-based instrument tracking scheme as a core algorithm to implement such functions was developed in this study. An automatic tracking scheme is proposed as a chain of computer vision techniques, including classification of metallic properties using k-means clustering and instrument movement tracking using similarity measures, Euclidean distance calculations, and a Kalman filter algorithm. The implemented system showed satisfactory performance in tests using actual robot-assisted surgery videos. Trajectory comparisons of automatically detected data and ground truth data obtained by manually locating the center of mass of each instrument were used to quantitatively validate the system. Instruments and collisions could be well tracked through the proposed methods. The developed collision warning system could provide valuable information to clinicians for safer procedures. © 2012, Copyright the Authors. Artificial Organs © 2012, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  5. Validation of ergonomic instructions in robot-assisted surgery simulator training.

    Science.gov (United States)

    Van't Hullenaar, C D P; Mertens, A C; Ruurda, J P; Broeders, I A M J

    2018-05-01

    Training in robot-assisted surgery focusses mainly on technical skills and instrument use. Training in optimal ergonomics during robotic surgery is often lacking, while improved ergonomics can be one of the key advantages of robot-assisted surgery. Therefore, the aim of this study was to assess whether a brief explanation on ergonomics of the console can improve body posture and performance. A comparative study was performed with 26 surgical interns and residents using the da Vinci skills simulator (Intuitive Surgical, Sunnyvale, CA). The intervention group received a compact instruction on ergonomic settings and coaching on clutch usage, while the control group received standard instructions for usage of the system. Participants performed two sets of five exercises. Analysis was performed on ergonomic score (RULA) and performance scores provided by the simulator. Mental and physical load scores (NASA-TLX and LED score) were also registered. The intervention group performed better in the clutch-oriented exercises, displaying less unnecessary movement and smaller deviation from the neutral position of the hands. The intervention group also scored significantly better on the RULA ergonomic score in both the exercises. No differences in overall performance scores and subjective scores were detected. The benefits of a brief instruction on ergonomics for novices are clear in this study. A single session of coaching and instruction leads to better ergonomic scores. The control group showed often inadequate ergonomic scores. No significant differences were found regarding physical discomfort, mental task load and overall performance scores.

  6. Robotic-assisted gastroplication in a morbidly obese adolescent: early improvement in metabolic and neurohormonal parameters

    Directory of Open Access Journals (Sweden)

    Valeria Calcaterra

    2012-12-01

    Full Text Available Bariatric surgery has to be considered in the management of severely obese adolescents when all conservative measures have been proven to be unresponsive. Short term metabolic and neurohormonal profile changes after robotic-assisted gastroplication are evaluated. The benefits and the usefulness of this surgical-reversal procedure in adolescent need to be defined. Fiveteen years old girl with body mass index 42.2 kg/m2, hyperinsulinism, hyperandrogenism, amenorrhea, polycystic ovarian syndrome, hypertension with left ventricular hypertrophy. Gastric volume after surgical procedure reduction was 80-100 mL. One month postoperatively significant weigh loss was obtained. Insulin levels, insulin-resistance, leptin and ghrelin concentration were substantially ameliorated. We can conclude that bariatric surgery should be considered for a minority of severely obese adolescents under the supervision of a multidisciplinary pediatric team. Our experience confirmed that the gastroplication is safe, feasible and effective and furthermore is a reversible technique. The early improvement of the obesity co-morbities is allowed. The increased surgical accuracy in robotic assistance could limit postoperative complications rate in obese adolescents.

  7. Robot-assisted ultrasound imaging: overview and development of a parallel telerobotic system.

    Science.gov (United States)

    Monfaredi, Reza; Wilson, Emmanuel; Azizi Koutenaei, Bamshad; Labrecque, Brendan; Leroy, Kristen; Goldie, James; Louis, Eric; Swerdlow, Daniel; Cleary, Kevin

    2015-02-01

    Ultrasound imaging is frequently used in medicine. The quality of ultrasound images is often dependent on the skill of the sonographer. Several researchers have proposed robotic systems to aid in ultrasound image acquisition. In this paper we first provide a short overview of robot-assisted ultrasound imaging (US). We categorize robot-assisted US imaging systems into three approaches: autonomous US imaging, teleoperated US imaging, and human-robot cooperation. For each approach several systems are introduced and briefly discussed. We then describe a compact six degree of freedom parallel mechanism telerobotic system for ultrasound imaging developed by our research team. The long-term goal of this work is to enable remote ultrasound scanning through teleoperation. This parallel mechanism allows for both translation and rotation of an ultrasound probe mounted on the top plate along with force control. Our experimental results confirmed good mechanical system performance with a positioning error of < 1 mm. Phantom experiments by a radiologist showed promising results with good image quality.

  8. Evolution of Robot-assisted ultrasound-guided breast biopsy systems

    Directory of Open Access Journals (Sweden)

    Mustafa Z. Mahmoud

    2018-01-01

    Full Text Available Robot-assisted ultrasound-guided breast biopsy combines ultrasound (US imaging with a robotic system for medical interventions. This study was designed to provide a literature review of a robotic US-guided breast biopsy system to delineate its efficacious impact on current medical practice. In addition, the strengths and limitations of this approach were also addressed. Articles published in the English language between 2000 and 2016 were appraised in this review. A wide range of systems that bind robotics with US imaging and guided breast biopsy were examined in this article. The fundamental safety and real-time imaging capabilities of US, together with the accuracy and maneuverability of robotic devices, is clearly an effective association with unmatched capabilities. Numerous experimental systems have obvious benefits over old-fashioned techniques, and the future of robot-assisted US-guided breast biopsy will be characterized by increasing levels of automation, and they hold tremendous possibility to impact doctor achievement, patient recovery, and clinical management.

  9. Laparoscopic Choledochoduodenostomy.

    Science.gov (United States)

    Cuendis-Velázquez, Adolfo; E Trejo-Ávila, Mario; Rosales-Castañeda, Enrique; Cárdenas-Lailson, Eduardo; E Rojano-Rodríguez, Martin; Romero-Loera, Sujey; A Sanjuan-Martínez, Carlos; Moreno-Portillo, Mucio

    Today's options for biliary bypass procedures, for difficult choledocholithiasis, range from open surgery to laparo-endoscopic hybrid procedures. The aim of this study was to analyze the outcomes of patients with difficult choledocholithiasis treated with laparoscopic choledochoduodenostomy. We performed a prospective observational study from March 2011 to June 2016. We included patients with difficult common bile duct stones (recurrent or unresolved by ERCP) in which a biliary bypass procedure was required. We performed a laparoscopic bile duct exploration with choledochoduodenostomy and intraoperative cholangioscopy. A total of 19 patients were included. We found female predominance (78.9%), advanced mean age (72.4±12 years) and multiple comorbidities. Most patients with previous episodes of choledocholitiasis or cholangitis, mode 1 (min-max: 1-7). Mean common bile duct diameter 24.9±7mm. Mean operative time 218.5±74min, estimated blood loss 150 (30-600)mL, resume of oral intake 3.2±1 days, postoperative length of stay 4.9±2 days. We found a median of 18 (12-32) months of follow-up. All patients with normalization of liver enzymes during follow-up. One patient presented with sump syndrome and one patient died due to nosocomial pneumonia. Laparoscopic choledochoduodenostomy with intraoperative cholangioscopy seems to be safe and effective treatment for patients with difficult common bile duct stones no resolved by endoscopic procedures. This procedure is a good option for patients with advanced age and multiple comorbidities. We offer all the advantages of minimally invasive surgery to these patients. Copyright © 2017 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  10. [Laser-based quality assurance for robot-assisted milling at the base of the skull].

    Science.gov (United States)

    Maassen, M M; Malthan, D; Stallkamp, J; Schäfer, A; Dammann, F; Schwaderer, E; Zenner, H P

    2006-02-01

    Implanting active hearing devices in the lateral base of the skull requires high-precision, secure fixation of the electromagnetic transducer and long-life anchorage using osteosynthetic fixation plates referred to as mountain brackets. Nonlinear distortion in the acoustic signal path and consecutive implant loosening can only be avoided by exact osseous milling to create the necessary cavity bed while avoiding excessive milling. Robot technology is ideal for high-precision milling. However, safety measures are necessary in order to prevent errors from occurring during the reduction process. Ideally, a robot should be guided by a navigation system. However, robotic systems so far available do not yet have an integrated global navigation system. We used an animal model under laboratory conditions to examine the extent to which the semiautomatic ROBIN assistant system developed could be expected to increase osseous milling accuracy before implanting active electronic hearing devices into the recipient tissue in the cranium. An existing prototype system for robot-assisted skull base surgery was equipped with laser sensors for geometric measurement of the operation site. The three-dimensional measurement data was compared with CT simulation data before, during, and after the robot-assisted operation. The experiments were conducted on test objects as well as on animal models. Under ideal conditions, the operation site could be measured at a spatial resolution of better than 0.02 mm in each dimension. However, reflections and impurities in the operation site from bleeding and rinsing fluids did have a considerable effect on data collection, necessitating specialised registering procedures. Using an error-tolerant procedure specifically developed, the effective registering error could be kept under 0.3 mm. After milling, the resulting shape matched the intended form at an accuracy level of 0.8 mm. The results show that robot systems can reach the accuracy required for

  11. Does robot-assisted gait training ameliorate gait abnormalities in multiple sclerosis? A pilot randomized-control trial.

    Science.gov (United States)

    Straudi, S; Benedetti, M G; Venturini, E; Manca, M; Foti, C; Basaglia, N

    2013-01-01

    Gait disorders are common in multiple sclerosis (MS) and lead to a progressive reduction of function and quality of life. Test the effects of robot-assisted gait rehabilitation in MS subjects through a pilot randomized-controlled study. We enrolled MS subjects with Expanded Disability Status Scale scores within 4.5-6.5. The experimental group received 12 robot-assisted gait training sessions over 6 weeks. The control group received the same amount of conventional physiotherapy. Outcomes measures were both biomechanical assessment of gait, including kinematics and spatio-temporal parameters, and clinical test of walking endurance (six-minute walk test) and mobility (Up and Go Test). 16 subjects (n = 8 experimental group, n = 8 control group) were included in the final analysis. At baseline the two groups were similar in all variables, except for step length. Data showed walking endurance, as well as spatio-temporal gait parameters improvements after robot-assisted gait training. Pelvic antiversion and reduced hip extension during terminal stance ameliorated after aforementioned intervention. Robot-assisted gait training seems to be effective in increasing walking competency in MS subjects. Moreover, it could be helpful in restoring the kinematic of the hip and pelvis.

  12. Nonalcoholic fatty liver disease in Japanese patients with severe obesity who received laparoscopic Roux-en-Y gastric bypass surgery (LRYGB) in comparison to non-Japanese patients

    International Nuclear Information System (INIS)

    Kakizaki, Satoru; Takizawa, Daichi; Yamazaki, Yuichi; Nakajima, Yuka; Ichikawa, Takeshi; Sato, Ken; Takagi, Hitoshi; Mori, Masatomo; Kasama, Kazunori

    2008-01-01

    The number of patients with morbid obesity is increasing worldwide. However, the prevalence of morbid obesity is still low in Japan, and therefore few systematic investigations of liver dysfunction in this population have so far been carried out. This study aimed to investigate the clinical characteristics in severe obese Japanese patients undergoing laparoscopic Roux-en-Y gastric bypass surgery (LRYGB). Eighty-four patients with severe obesity, including 61 Japanese and 23 non-Japanese patients, were analyzed. The mean body mass index (BMI) was 43.7±7.8 kg/m 2 , and there was no difference between Japanese and non-Japanese patients. Nonalcoholic fatty liver disease (NAFLD) was observed in 45/59 (76.2%) of the Japanese patients. Although there were no differences in the BMI and body weight, serum alanine aminotransferase (ALT) was higher in Japanese patients in comparison to non-Japanese patients (P<0.05). The indices for insulin resistance were significantly higher in the Japanese patients in comparison to non-Japanese patients (P<0.01). The liver/spleen computed tomography (CT) ratios were lower in Japanese patients (P<0.05). The laboratory data and BMI significantly improved at 1 year after LRYGB in both groups. Racial difference may exist difference may exist in NAFLD in patients with severe obesity. When the BMI is similar, liver dysfunction among Japanese patients with severe obesity tends to be higher than in non-Japanese patients. Japanese patients with severe obesity must therefore reduce their body weight to a greater degree in comparison to non-Japanese patients with the same BMI. LRYGB can achieve effective weight control and lower ALT levels in Japanese patients with severe obesity. (author)

  13. Acoustic Emission Based In-process Monitoring in Robot Assisted Polishing

    DEFF Research Database (Denmark)

    Pilny, Lukas; Bissacco, Giuliano; De Chiffre, Leonardo

    The applicability of acoustic emission (AE) measurements for in-process monitoring in the Robot Assisted Polishing (RAP) process was investigated. Surface roughness measurements require interruption of the process, proper surface cleaning and measurements that sometimes necessitate removal...... improving the efficiency of the process. It also allows for intelligent process control and generally enhances the robustness and reliability of the automated RAP system in industrial applications....... of the part from the machine tool. In this study, development of surface roughness during polishing rotational symmetric surfaces by the RAP process was inferred from AE measurements. An AE sensor was placed on a polishing tool, and a cylindrical rod of Vanadis 4E steel having an initial turned surface...

  14. The effect of a robot-assisted surgical system on the kinematics of user movements.

    Science.gov (United States)

    Nisky, Ilana; Hsieh, Michael H; Okamura, Allison M

    2013-01-01

    Teleoperated robot-assisted surgery (RAS) offers many advantages over traditional minimally invasive surgery. However, RAS has not yet realized its full potential, and it is not clear how to optimally train surgeons to use these systems. We hypothesize that the dynamics of the master manipulator impact the ability of users to make desired movements with the robot. We compared freehand and teleoperated movements of novices and experienced surgeons. To isolate the effects of dynamics from procedural knowledge, we chose simple movements rather than surgical tasks. We found statistically significant effects of teleoperation and user expertise in several aspects of motion, including target acquisition error, movement speed, and movement smoothness. Such quantitative assessment of human motor performance in RAS can impact the design of surgical robots, their control, and surgeon training methods, and eventually, improve patient outcomes.

  15. Measuring the Latency of an Augmented Reality System for Robot-Assisted Minimally Invasive Surgery

    DEFF Research Database (Denmark)

    Jørgensen, Martin Kibsgaard; Kraus, Martin

    2017-01-01

    Minimal latency is important for augmented reality systems and teleoperation interfaces as even small increases in latency can affect user performance. Previously, we have developed an augmented reality system that can overlay stereoscopic video streams with computer graphics in order to improve....... The latency of the da Vinci S surgical system was on average 62 ms. None of the components of our overlay system (separately or combined) significantly affected the latency. However, the latency of the assistant's monitor increased by 14 ms. Passing the video streams through CPU or GPU memory increased...... visual communication in training for robot-assisted minimally invasive surgery with da Vinci surgical systems. To make sure that our augmented reality system provides the best possible user experience, we investigated the video latency of the da Vinci surgical system and how the components of our system...

  16. Iatrogenic Lower Extremity Subcutaneous Emphysema after Prolonged Robotic-Assisted Hysterectomy

    Directory of Open Access Journals (Sweden)

    Monica Hagan Vetter

    2015-01-01

    Full Text Available Subcutaneous emphysema is a known complication of carbon dioxide insufflation, an essential component of laparoscopy. The literature contains reports of hypercarbia, pneumothorax, or pneumomediastinum. However, isolated lower extremity subcutaneous emphysema remains a seldom-reported complication. We report a case of unilateral lower extremity subcutaneous emphysema following robotic-assisted hysterectomy, bilateral salpingooophorectomy, staging, and anterior/posterior colporrhaphy for carcinosarcoma and vaginal prolapse. On postoperative day 1, the patient developed tender crepitus and bruising of her right ankle. Radiography confirmed presence of subcutaneous air. Vital signs and laboratory findings were unremarkable. Her symptoms spontaneously improved over time, and she was discharged in good condition on day 2. In stable patients with postoperative extremity swelling or pain with crepitus on exam, the diagnosis of iatrogenic subcutaneous emphysema must be considered.

  17. Robot-assisted ligation of bronchial artery could be an alternative to embolization.

    Science.gov (United States)

    Pochulu, Bruno; Sarsam, Omar; Peillon, Christophe; Baste, Jean-Marc

    2018-03-01

    A 37-year-old patient presented with a self-limiting episode of moderate haemoptysis. Contrast-enhanced chest computed tomography showed a tortuous and dilated right bronchial artery arising from the descending aorta at the level of T6. Therapeutic angiography was attempted, but in the presence of spinal artery arising from the bronchial artery in question, selective embolization was contraindicated due to risk of spinal cord ischaemia. After a multidisciplinary meeting, it was decided to attempt surgery to ligate this pathological artery. We performed minimally invasive robot-assisted ligation of this pathological artery. The postoperative course was uneventful with good clinical and radiological outcome at 3-month follow-up. A minimally invasive approach provides a real alternative to embolization and could be a therapeutic option.

  18. [Robotic-assisted minimally invasive abdominothoracal oesophageal resection with intrathoracic anastomosis].

    Science.gov (United States)

    Egberts, J-H; Aselmann, H; Schafmayer, C; Jünemann, K-P; Becker, T

    2014-02-01

    Ivor Lewis oesophagectomy is one of the approaches used worldwide for treating oesophageal cancer. The adoption of minimally invasive oesophagectomy has increased worldwide since its first description more than 15 years ago. However, minimally invasive oesophagectomy with a chest anastomosis has advantages. By using a four-arm robotic platform, not only the preparation of the gastric tube and mobilisation of the oesophagus but also the intrathoracic anastomosis of the oesophagogastrostomy can be performed in a comfortable and safe way. The indication for oesophageal resection is oesophageal cancer. The operative procedure comprises robotic-assisted abdominothoracal oesophageal resection with reconstruction by a gastric tube and intrathoracic anastomosis (Ivor Lewis procedure). Robotic abdominal and thoracic minimally invasive esophagectomy is feasible, and safe with a complete lymph node dissection. Especially the intrathoracic anastomosis of the oesophagogastrostomy can be performed in a comfortable and safe way. Georg Thieme Verlag KG Stuttgart · New York.

  19. Consistency of performance of robot-assisted surgical tasks in virtual reality.

    Science.gov (United States)

    Suh, I H; Siu, K-C; Mukherjee, M; Monk, E; Oleynikov, D; Stergiou, N

    2009-01-01

    The purpose of this study was to investigate consistency of performance of robot-assisted surgical tasks in a virtual reality environment. Eight subjects performed two surgical tasks, bimanual carrying and needle passing, with both the da Vinci surgical robot and a virtual reality equivalent environment. Nonlinear analysis was utilized to evaluate consistency of performance by calculating the regularity and the amount of divergence in the movement trajectories of the surgical instrument tips. Our results revealed that movement patterns for both training tasks were statistically similar between the two environments. Consistency of performance as measured by nonlinear analysis could be an appropriate methodology to evaluate the complexity of the training tasks between actual and virtual environments and assist in developing better surgical training programs.

  20. Towards Robot-Assisted Echocardiographic Monitoring in Catheterization Laboratories : Usability-Centered Manipulator for Transesophageal Echocardiography.

    Science.gov (United States)

    Pahl, Christina; Ebelt, Henning; Sayahkarajy, Mostafa; Supriyanto, Eko; Soesanto, Amiliana

    2017-08-15

    This paper proposes a robotic Transesophageal Echocardiography (TOE) system concept for Catheterization Laboratories. Cardiovascular disease causes one third of all global mortality. TOE is utilized to assess cardiovascular structures and monitor cardiac function during diagnostic procedures and catheter-based structural interventions. However, the operation of TOE underlies various conditions that may cause a negative impact on performance, the health of the cardiac sonographer and patient safety. These factors have been conflated and evince the potential of robot-assisted TOE. Hence, a careful integration of clinical experience and Systems Engineering methods was used to develop a concept and physical model for TOE manipulation. The motion of different actuators of the fabricated motorized system has been tested. It is concluded that the developed medical system, counteracting conflated disadvantages, represents a progressive approach for cardiac healthcare.

  1. Early biochemical recurrence, urinary continence and potency outcomes following robot-assisted radical prostatectomy

    DEFF Research Database (Denmark)

    Berg, Kasper Drimer; Thomsen, Frederik Birkebæk; Hvarness, Helle

    2014-01-01

    OBJECTIVE: The aim of this study was to describe recovery of urinary continence and potency and report oncological and functional outcomes using the survival, continence and potency (SCP) system for patients undergoing robot-assisted radical prostatectomy (RARP). MATERIAL AND METHODS: From 2009...... with preoperative ESI, 77.6% (67.9-86.1) and 34.4% (24.1-47.5) maintained ESI 12 months postoperatively after bilateral and unilateral nerve-sparing surgery (NS), respectively. NS (p .... Using the SCP system and defining potency as ESI, functional and oncological success 12 months after surgery was achieved in 69 out of 135 (51.1%) preoperative continent and potent patients who underwent unilateral or bilateral NS, and did not require adjuvant treatment; when defining potency as IIEF...

  2. Percutaneous Sacroiliac Screw Placement: A Prospective Randomized Comparison of Robot-assisted Navigation Procedures with a Conventional Technique

    Science.gov (United States)

    Wang, Jun-Qiang; Wang, Yu; Feng, Yun; Han, Wei; Su, Yong-Gang; Liu, Wen-Yong; Zhang, Wei-Jun; Wu, Xin-Bao; Wang, Man-Yi; Fan, Yu-Bo

    2017-01-01

    Background: Sacroiliac (SI) screw fixation is a demanding technique, with a high rate of screw malposition due to the complex pelvic anatomy. TiRobot™ is an orthopedic surgery robot which can be used for SI screw fixation. This study aimed to evaluate the accuracy of robot-assisted placement of SI screws compared with a freehand technique. Methods: Thirty patients requiring posterior pelvic ring stabilization were randomized to receive freehand or robot-assisted SI screw fixation, between January 2016 and June 2016 at Beijing Jishuitan Hospital. Forty-five screws were placed at levels S1 and S2. In both methods, the primary end point screw position was assessed and classified using postoperative computed tomography. Fisher's exact probability test was used to analyze the screws’ positions. Secondary end points, such as duration of trajectory planning, surgical time after reduction of the pelvis, insertion time for guide wire, number of guide wire attempts, and radiation exposure without pelvic reduction, were also assessed. Results: Twenty-three screws were placed in the robot-assisted group and 22 screws in the freehand group; no postoperative complications or revisions were reported. The excellent and good rate of screw placement was 100% in the robot-assisted group and 95% in the freehand group. The P value (0.009) showed the same superiority in screw distribution. The fluoroscopy time after pelvic reduction in the robot-assisted group was significantly shorter than that in the freehand group (median [Q1, Q3]: 6.0 [6.0, 9.0] s vs. median [Q1, Q3]: 36.0 [21.5, 48.0] s; χ2 = 13.590, respectively, P < 0.001); no difference in operation time after reduction of the pelvis was noted (χ2 = 1.990, P = 0.158). Time for guide wire insertion was significantly shorter for the robot-assisted group than that for the freehand group (median [Q1, Q3]: 2.0 [2.0, 2.7] min vs. median [Q1, Q3]: 19.0 [15.5, 45.0] min; χ2 = 20.952, respectively, P < 0.001). The number of guide

  3. Robot-assisted radical cystectomy with intracorporeal neobladder diversion: The Karolinska experience.

    Science.gov (United States)

    Collins, Justin W; Sooriakumaran, P; Sanchez-Salas, R; Ahonen, R; Nyberg, T; Wiklund, N P; Hosseini, A

    2014-07-01

    The aim of this report is to describe our surgical technique of totally intracorporeal robotic assisted radical cystectomy (RARC) with neobladder formation. Between December 2003 and March 2013, a total of 147 patients (118 male, 29 female) underwent totally intracorporeal RARC for urinary bladder cancer. We also performed a systematic search of Medline, Embase and PubMed databases using the terms RARC, robotic cystectomy, robot-assisted, totally intracorporeal RARC, intracorporeal neobladder, intracorporeal urinary diversion, oncological outcomes, functional outcomes, and complication rates. The mean age of our patients was 64 years (range 37-87). On surgical pathology 47% had pT1 or less disease, 27% had pT2, 16% had pT3 and 10% had pT4. The mean number of lymph nodes removed was 21 (range 0-60). 24% of patients had lymph node positive dAQ1isease. Positive surgical margins occurred in 6 cases (4%). Mean follow-up was 31 months (range 4-115 months). Two patients (1.4%) died within 90 days of their operation. Using Kaplan-Meier analysis, overall survival and cancer specific survival at 60 months was 68% and 69.6%, respectively. 80 patients (54%) received a continent diversion with totally intracorporeal neobladder formation. In the neobladder subgroup median total operating time was 420 minutes (range 265-760). Daytime continence and satisfactory sexual function or potency at 12 months ranged between 70-90% in both men and women. Our experience with totally intracorporeal RARC demonstrates acceptable oncological and functional outcomes that suggest this is a viable alternative to open radical cystectomy.

  4. In vivo kinematics of a robot-assisted uni- and multi-compartmental knee arthroplasty.

    Science.gov (United States)

    Watanabe, Toshifumi; Abbasi, Ali Z; Conditt, Michael A; Christopher, Jennifer; Kreuzer, Stefan; Otto, Jason K; Banks, Scott A

    2014-07-01

    There is great interest in providing reliable and durable treatments for one- and two-compartment arthritic degeneration of the cruciate-ligament intact knee. One approach is to resurface only the diseased compartments with discrete unicompartmental components, retaining the undamaged compartment(s). However, placing multiple small implants into the knee presents a greater surgical challenge than total knee arthroplasty, so it is not certain that the natural knee mechanics can be maintained or restored. The goal of this study was to determine whether near-normal knee kinematics can be obtained with a robot-assisted multi-compartmental knee arthroplasty. Thirteen patients with 15 multi-compartmental knee arthroplasties using haptic robotic-assisted bone preparation were involved in this study. Nine subjects received a medial unicompartmental knee arthroplasty (UKA), three subjects received a medial UKA and patellofemoral (PF) arthroplasty, and three subjects received medial and lateral bi-unicondylar arthroplasty. Knee motions were recorded using video-fluoroscopy an average of 13 months (6-29 months) after surgery during stair and kneeling activities. The three-dimensional position and orientation of the implant components were determined using model-image registration techniques. Knee kinematics during maximum flexion kneeling showed femoral external rotation and posterior lateral condylar translation. All knees showed femoral external rotation and posterior condylar translation with flexion during the step activity. Knees with medial UKA and PF arthroplasty showed the most femoral external rotation and posterior translation, and knees with bicondylar UKA showed the least. Knees with accurately placed uni- or bi-compartmental arthroplasty exhibited stable knee kinematics consistent with intact and functioning cruciate ligaments. The patterns of tibiofemoral motion were more similar to natural knees than commonly has been observed in knees with total knee

  5. Anticipation, teamwork and cognitive load: chasing efficiency during robot-assisted surgery.

    Science.gov (United States)

    Sexton, Kevin; Johnson, Amanda; Gotsch, Amanda; Hussein, Ahmed A; Cavuoto, Lora; Guru, Khurshid A

    2018-02-01

    Robot-assisted surgery (RAS) has changed the traditional operating room (OR), occupying more space with equipment and isolating console surgeons away from the patients and their team. We aimed to evaluate how anticipation of surgical steps and familiarity between team members impacted efficiency. We analysed recordings (video and audio) of 12 robot-assisted radical prostatectomies. Any requests between surgeon and the team members were documented and classified by personnel, equipment type, mode of communication, level of inconvenience in fulfilling the request and anticipation. Surgical team members completed questionnaires assessing team familiarity and cognitive load (National Aeronautics and Space Administration - Task Load Index). Predictors of team efficiency were assessed using Pearson correlation and stepwise linear regression. 1330 requests were documented, of which 413 (31%) were anticipated. Anticipation correlated negatively with operative time, resulting in overall 8% reduction of OR time. Team familiarity negatively correlated with inconveniences. Anticipation ratio, per cent of requests that were non-verbal and total request duration were significantly correlated with the console surgeons' cognitive load (r=0.77, p=0.006; r=0.63, p=0.04; and r=0.70, p=0.02, respectively). Anticipation and active engagement by the surgical team resulted in shorter operative time, and higher familiarity scores were associated with fewer inconveniences. Less anticipation and non-verbal requests were also associated with lower cognitive load for the console surgeon. Training efforts to increase anticipation and team familiarity can improve team efficiency during RAS. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  6. Robot-assisted single port radical nephrectomy and cholecystectomy: description and technical aspects.

    Science.gov (United States)

    Mota Filho, Francisco Hidelbrando Alves; Sávio, Luis Felipe; Sakata, Rafael Eiji; Ivanovic, Renato Fidelis; da Silva, Marco Antonio Nunes; Maia, Ronaldo; Passerotti, Carlo

    2018-01-01

    Robot-Assisted Single Site Radical Nephrectomy (RASS-RN) has been reported by surgeons in Europe and United States (1-3). To our best knowledge this video presents the first RASS-RN with concomitant cholecystectomy performed in Latin America. A 66 year-old renal transplant male due to chronic renal failure presented with an incidental 1.3cm nodule in the upper pole of the right kidney. In addition, symptomatic gallbladder stones were detected. Patient was placed in modified flank position. Multichannel single port device was placed using Hassan's technique through a 3cm supra-umbilical incision. Standard radical nephrectomy and cholecystectomy were made using na 8.5mm camera, two 5mm robotic arms and an assistant 5mm access. Surgery time and estimated blood loss were 208 minutes and 100mL, respectively. Patient did well and was discharged within less than 48 hours, without complications. Pathology report showed benign renomedullary tumor of interstitial cells and chronic cholecystitis. Robotic technology improves ergonomics, gives better precision and enhances ability to approach complex surgeries. Robot-assisted Single Port aims to reduce the morbidity of multiple trocar placements while maintaining the advantages of robotic surgery (2). Limitations include the use of semi-rigid instruments providing less degree of motion and limited space leading to crash between instruments. On the other hand, it is possible to perform complex and concomitant surgeries with just one incision. RASS-RN seems to be safe and feasible option for selected cases. Studies should be performed to better understand the results using single port technique in Urology. Copyright® by the International Brazilian Journal of Urology.

  7. Robot-assisted single port radical nephrectomy and cholecystectomy: description and technical aspects

    Directory of Open Access Journals (Sweden)

    Francisco Hidelbrando Alves Mota Filho

    Full Text Available ABSTRACT Introduction Robot-Assisted Single Site Radical Nephrectomy (RASS-RN has been reported by surgeons in Europe and United States (1–3. To our best knowledge this video presents the first RASS-RN with concomitant cholecystectomy performed in Latin America. Case A 66 year-old renal transplant male due to chronic renal failure presented with an incidental 1.3cm nodule in the upper pole of the right kidney. In addition, symptomatic gallbladder stones were detected. Results Patient was placed in modified flank position. Multichannel single port device was placed using Hassan's technique through a 3 cm supra-umbilical incision. Standard radical nephrectomy and cholecystectomy were made using an 8.5mm camera, two 5mm robotic arms and an assistant 5mm access. Surgery time and estimated blood loss were 208 minutes and 100mL, respectively. Patient did well and was discharged within less than 48 hours, without complications. Pathology report showed benign renomedullary tumor of interstitial cells and chronic cholecystitis. Discussion Robotic technology improves ergonomics, gives better precision and enhances ability to approach complex surgeries. Robot-assisted Single Port aims to reduce the morbidity of multiple trocar placements while maintaining the advantages of robotic surgery (2. Limitations include the use of semi-rigid instruments providing less degree of motion and limited space leading to crash between instruments. On the other hand, it is possible to perform complex and concomitant surgeries with just one incision. Conclusion RASS-RN seems to be safe and feasible option for selected cases. Studies should be performed to better understand the results using single port technique in Urology.

  8. Robot-assisted gait training in patients with Parkinson disease: a randomized controlled trial.

    Science.gov (United States)

    Picelli, Alessandro; Melotti, Camilla; Origano, Francesca; Waldner, Andreas; Fiaschi, Antonio; Santilli, Valter; Smania, Nicola

    2012-05-01

    . Gait impairment is a common cause of disability in Parkinson disease (PD). Electromechanical devices to assist stepping have been suggested as a potential intervention. . To evaluate whether a rehabilitation program of robot-assisted gait training (RAGT) is more effective than conventional physiotherapy to improve walking. . A total of 41 patients with PD were randomly assigned to 45-minute treatment sessions (12 in all), 3 days a week, for 4 consecutive weeks of either robotic stepper training (RST; n = 21) using the Gait Trainer or physiotherapy (PT; n = 20) with active joint mobilization and a modest amount of conventional gait training. Participants were evaluated before, immediately after, and 1 month after treatment. Primary outcomes were 10-m walking speed and distance walked in 6 minutes. . Baseline measures revealed no statistical differences between groups, but the PT group walked 0.12 m/s slower; 5 patients withdrew. A statistically significant improvement was found in favor of the RST group (walking speed 1.22 ± 0.19 m/s [P = .035]; distance 366.06 ± 78.54 m [P < .001]) compared with the PT group (0.98 ± 0.32 m/s; 280.11 ± 106.61 m). The RAGT mean speed increased by 0.13 m/s, which is probably not clinically important. Improvements were maintained 1 month later. . RAGT may improve aspects of walking ability in patients with PD. Future trials should compare robotic assistive training with treadmill or equal amounts of overground walking practice.

  9. Robot-assisted training for heart failure patients - a small pilot study.

    Science.gov (United States)

    Schoenrath, Felix; Markendorf, Susanne; Brauchlin, Andreas Emil; Frank, Michelle; Wilhelm, Markus Johannes; Saleh, Lanja; Riener, Robert; Schmied, Christian Marc; Falk, Volkmar

    2015-12-01

    The objective of this study was assess robot-assisted gait therapy with the Lokomat® system in heart failure patients. Patients (n = 5) with stable heart failure and a left ventricular ejection fraction of less than 45% completed a four-week aerobic training period with three trainings per week and an integrated dynamic resistance training of the lower limbs. Patients underwent testing of cardiac and inflammatory biomarkers. A cardiopulmonary exercise test, a quality of life score and an evaluation of the muscular strength by measuring the peak quadriceps force was performed. No adverse events occurred. The combined training resulted in an improvement in peak work rate (range: 6% to 36%) and peak quadriceps force (range: 3% to 80%) in all participants. Peak oxygen consumption (range: –3% to + 61%) increased in three, and oxygen pulse (range: –7% to + 44%) in four of five patients. The quality of life assessment indicated better well-being in all participants. NT-ProBNP (+233 to –733 ng/ml) and the inflammatory biomarkers (hsCRP and IL6) decreased in four of five patients (IL 6: +0.5 to –2 mg/l, hsCRP: +0.2 to –6.5 mg/l). Robot-assisted gait therapy with the Lokomat® System is feasible in heart failure patients and was safe in this trial. The combined aerobic and resistance training intervention with augmented feedback resulted in benefits in exercise capacity, muscle strength and quality of life, as well as an improvement of cardiac (NT-ProBNP) and inflammatory (IL6, hsCRP) biomarkers. Results can only be considered as preliminary and need further validation in larger studies. (ClinicalTrials.gov number, NCT 02146196)

  10. Comparison of fiber delivered CO2 laser and electrocautery in transoral robot assisted tongue base surgery.

    Science.gov (United States)

    Karaman, Murat; Gün, Taylan; Temelkuran, Burak; Aynacı, Engin; Kaya, Cem; Tekin, Ahmet Mahmut

    2017-05-01

    To compare intra-operative and post-operative effectiveness of fiber delivered CO 2 laser to monopolar electrocautery in robot assisted tongue base surgery. Prospective non-randomized clinical study. Twenty moderate to severe obstructive sleep apnea (OSA) patients, non-compliant with Continuous Positive Airway Pressure (CPAP), underwent Transoral Robotic Surgery (TORS) using the Da Vinci surgical robot in our University Hospital. OSA was treated with monopolar electrocautery in 10 patients, and with flexible CO 2 laser fiber in another 10 patients. The following parameters in the two sets are analyzed: Intraoperative bleeding that required cauterization, robot operating time, need for tracheotomy, postoperative self-limiting bleeding, length of hospitalization, duration until start of oral intake, pre-operative and post-operative minimum arterial oxygen saturation, pre-operative and post-operative Epworth Sleepiness Scale score, postoperative airway complication and postoperative pain. Mean follow-up was 12 months. None of the patients required tracheotomy and there were no intraoperative complications related to the use of the robot or the CO 2 laser. The use of CO 2 laser in TORS-assisted tongue base surgery resulted in less intraoperative bleeding that required cauterization, shorter robot operating time, shorter length of hospitalization, shorter duration until start of oral intake and less postoperative pain, when compared to electrocautery. Postoperative apnea-hypopnea index scores showed better efficacy of CO 2 laser than electrocautery. Comparison of postoperative airway complication rates and Epworth sleepiness scale scores were found to be statistically insignificant between the two groups. The use of CO 2 laser in robot assisted tongue base surgery has various intraoperative and post-operative advantages when compared to monopolar electrocautery.

  11. Positioning the laparoscopic camera with industrial robot arm

    DEFF Research Database (Denmark)

    Capolei, Marie Claire; Wu, Haiyan; Andersen, Nils Axel

    2017-01-01

    This paper introduces a solution for the movement control of the laparoscopic camera employing a teleoperated robotic assistant. The project propose an autonomous robotic solution based on an industrial manipulator, provided with a modular software which is applicable to large scale. The robot arm...... industrial robot arm is designated to accomplish this manipulation task. The software is implemented in ROS in order to facilitate future extensions. The experimental results shows a manipulator capable of moving fast and smoothly the surgical tool around a remote center of motion....

  12. The Experience of Robotic-Assisted Laparoscopic Hysterectomy for Women Treated for Early-Stage Endometrial Cancer

    DEFF Research Database (Denmark)

    Herling, Suzanne Forsyth; Palle, Connie; Moeller, Ann M

    2016-01-01

    , the women did not consider themselves surviving cancer patients but as cured. The women searched for information from various sources, for example, the Internet and the online patient chart, to prepare for surgery and to come to terms with the diagnosis. CONCLUSIONS: Although the women had confidence...... activity is needed. Individualized information about anatomical changes after surgery is warranted, preferably using anatomical drawings. Potentially, the women could benefit from attending a nursing clinic during the first postoperative months....

  13. Outcomes of a virtual-reality simulator-training programme on basic surgical skills in robot-assisted laparoscopic surgery.

    Science.gov (United States)

    Phé, Véronique; Cattarino, Susanna; Parra, Jérôme; Bitker, Marc-Olivier; Ambrogi, Vanina; Vaessen, Christophe; Rouprêt, Morgan

    2017-06-01

    The utility of the virtual-reality robotic simulator in training programmes has not been clearly evaluated. Our aim was to evaluate the impact of a virtual-reality robotic simulator-training programme on basic surgical skills. A simulator-training programme in robotic surgery, using the da Vinci Skills Simulator, was evaluated in a population including junior and seasoned surgeons, and non-physicians. Their performances on robotic dots and suturing-skin pod platforms before and after virtual-simulation training were rated anonymously by surgeons experienced in robotics. 39 participants were enrolled: 14 medical students and residents in surgery, 14 seasoned surgeons, 11 non-physicians. Junior and seasoned surgeons' performances on platforms were not significantly improved after virtual-reality robotic simulation in any of the skill domains, in contrast to non-physicians. The benefits of virtual-reality simulator training on several tasks to basic skills in robotic surgery were not obvious among surgeons in our initial and early experience with the simulator. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  14. Robot-assisted posterior retroperitoneoscopic adrenalectomy using single-port access: technical feasibility and preliminary results.

    Science.gov (United States)

    Park, Jae Hyun; Kim, Soo Young; Lee, Cho-Rok; Park, Seulkee; Jeong, Jun Soo; Kang, Sang-Wook; Jeong, Jong Ju; Nam, Kee-Hyun; Chung, Woong Youn; Park, Cheong Soo

    2013-08-01

    Posterior retroperitoneoscopic adrenalectomy (PRA) has several benefits compared with transperitoneal adrenalectomy in that it is safe and has a short learning curve. In addition, it provides direct short access to the target organ, prevents irritation to the intraperitoneal space, and does not require retraction of adjacent organs.1 (-) 3 We have performed several cases of robot-assisted PRA using single-port access for small adrenal tumors. This multimedia article introduces the detailed methods and preliminary results of this procedure. Five patients underwent single-port robot-assisted PRA between March 2010 and June 2011 at our institution. During the procedure, patients were placed in a prone jackknife position with their hip joints bent at a right angle (Fig. 1). A 3 cm transverse skin incision was made just below the lowest tip of the 12th rib (Fig. 2), and the Glove port (Nelis, Kyung-gi, Korea) was placed through the skin incision while maintaining pneumoretroperitoneum (Fig. 3). CO2 was then insufflated to a pressure of 18 mm Hg to create an adequate working space. A 10 mm robotic camera with a 30-degree up view was placed at the center of the incision through the most cephalic portion of the Glove port. A Maryland dissector or Prograsp forceps (Intuitive Surgical, Inc., Sunnyvale, CA) was placed on the medial side of the incision, and Harmonic curved shears (Intuitive Surgical) were placed on the lateral side of the incision (Fig. 4). Using the Maryland dissector and the harmonic curved shears, the Gerota fascia is opened, perinephric fat is dissected, and the kidney upper pole is mobilized to expose the adrenal gland (Fig. 5). Gland dissection starts with lower margin detachment from the upper kidney pole in a lateral to medial direction (Fig. 6). After dissecting the adrenal gland from surrounding adipose tissue and medial isolation of the adrenal central vein, the vessel is ligated with a 5 mm hemolock clip (Fig. 7). Patient

  15. Decreased Time to Return to Work Using Robotic-Assisted Unicompartmental Knee Arthroplasty Compared to Conventional Techniques.

    Science.gov (United States)

    Jinnah, Alexander H; Augart, Marco A; Lara, Daniel L; Jinnah, Riyaz H; Poehling, Gary G; Gwam, Chukwuweike U; Plate, Johannes F

    2018-06-01

    Unicompartmental knee arthroplasty (UKA) is a commonly used procedure for patients suffering from debilitating unicompartmental knee arthritis. For UKA recipients, robotic-assisted surgery has served as an aid in improving surgical accuracy and precision. While studies exist detailing outcomes of robotic UKA, to our knowledge, there are no studies assessing time to return to work using robotic-assisted UKA. Thus, the purpose of this study was to prospectively assess the time to return to work and to achieve the level of work activity following robotic-assisted UKA to create recommendations for patients preoperatively. We hypothesized that the return to work time would be shorter for robotic-assisted UKAs compared with TKAs and manual UKAs, due to more accurate ligament balancing and precise implementation of the operative plan. Thirty consecutive patients scheduled to undergo a robotic-assisted UKA at an academic teaching hospital were prospectively enrolled in the study. Inclusion criteria included employment at the time of surgery, with the intent on returning to the same occupation following surgery and having end-stage knee degenerative joint disease (DJD) limited to the medial compartment. Patients were contacted via email, letter, or phone at two, four, six, and 12 weeks following surgery until they returned to work. The Baecke physical activity questionnaire (BQ) was administered to assess patients' level of activity at work pre- and postoperatively. Statistical analysis was performed using SAS Enterprise Guide (SAS Institute Inc., Cary, North Carolina) and Excel® (Microsoft Corporation, Redmond, Washington). Descriptive statistics were calculated to assess the demographics of the patient population. Boxplots were generated using an Excel® spreadsheet to visualize the BQ scores and a two-tailed t-test was used to assess for differences between pre- and postoperative scores with alpha 0.05. The mean time to return to work was 6.4 weeks (SD=3.4, range 2

  16. Robotic-Assisted Procedures in Pediatric Surgery: A Critical Appraisal of the Current Best Evidence in Comparison to Conventional Minimally Invasive Surgery.

    Science.gov (United States)

    Friedmacher, Florian; Till, Holger

    2015-11-01

    In recent years, the use of robotic-assisted surgery (RAS) has expanded within pediatric surgery. Although increasing numbers of pediatric RAS case-series have been published, the level of evidence remains unclear, with authors mainly focusing on the comparison with open surgery rather than the corresponding laparoscopic approach. The aim of this study was to critically appraise the published literature comparing pediatric RAS with conventional minimally invasive surgery (MIS) in order to evaluate the current best level of evidence. A systematic literature-based search for studies comparing pediatric RAS with corresponding MIS procedures was performed using multiple electronic databases and sources. The level of evidence was determined using the Oxford Centre for Evidence-based Medicine (OCEBM) criteria. A total of 20 studies met defined inclusion criteria, reporting on five different procedures: fundoplication (n=8), pyeloplasty (n=8), nephrectomy (n=2), gastric banding (n=1), and sleeve gastrectomy (n=1). Included publications comprised 5 systematic reviews and 15 cohort/case-control studies (OCEBM Level 3 and 4, respectively). No studies of OCEBM Level 1 or 2 were identified. Limited evidence indicated reduced operative time (pyeloplasty) and shorter hospital stay (fundoplication) for pediatric RAS, whereas disadvantages were longer operative time (fundoplication, nephrectomy, gastric banding, and sleeve gastrectomy) and higher total costs (fundoplication and sleeve gastrectomy). There were no differences reported for complications, success rates, or short-term outcomes between pediatric RAS and conventional MIS in these procedures. Inconsistency was found in study design and follow-up with large clinical heterogeneity. The best available evidence for pediatric RAS is currently OCEBM Level 3, relating only to fundoplication and pyeloplasty. Therefore, higher-quality studies and comparative data for other RAS procedures in pediatric surgery are required.

  17. A Systematic Review of Virtual Reality Simulators for Robot-assisted Surgery.

    Science.gov (United States)

    Moglia, Andrea; Ferrari, Vincenzo; Morelli, Luca; Ferrari, Mauro; Mosca, Franco; Cuschieri, Alfred

    2016-06-01

    No single large published randomized controlled trial (RCT) has confirmed the efficacy of virtual simulators in the acquisition of skills to the standard required for safe clinical robotic surgery. This remains the main obstacle for the adoption of these virtual simulators in surgical residency curricula. To evaluate the level of evidence in published studies on the efficacy of training on virtual simulators for robotic surgery. In April 2015 a literature search was conducted on PubMed, Web of Science, Scopus, Cochrane Library, the Clinical Trials Database (US) and the Meta Register of Controlled Trials. All publications were scrutinized for relevance to the review and for assessment of the levels of evidence provided using the classification developed by the Oxford Centre for Evidence-Based Medicine. The publications included in the review consisted of one RCT and 28 cohort studies on validity, and seven RCTs and two cohort studies on skills transfer from virtual simulators to robot-assisted surgery. Simulators were rated good for realism (face validity) and for usefulness as a training tool (content validity). However, the studies included used various simulation training methodologies, limiting the assessment of construct validity. The review confirms the absence of any consensus on which tasks and metrics are the most effective for the da Vinci Skills Simulator and dV-Trainer, the most widely investigated systems. Although there is consensus for the RoSS simulator, this is based on only two studies on construct validity involving four exercises. One study on initial evaluation of an augmented reality module for partial nephrectomy using the dV-Trainer reported high correlation (r=0.8) between in vivo porcine nephrectomy and a virtual renorrhaphy task according to the overall Global Evaluation Assessment of Robotic Surgery (GEARS) score. In one RCT on skills transfer, the experimental group outperformed the control group, with a significant difference in overall

  18. Robot-assisted Salvage Lymph Node Dissection for Clinically Recurrent Prostate Cancer.

    Science.gov (United States)

    Montorsi, Francesco; Gandaglia, Giorgio; Fossati, Nicola; Suardi, Nazareno; Pultrone, Cristian; De Groote, Ruben; Dovey, Zach; Umari, Paolo; Gallina, Andrea; Briganti, Alberto; Mottrie, Alexandre

    2017-09-01

    Salvage lymph node dissection has been described as a feasible treatment for the management of prostate cancer patients with nodal recurrence after primary treatment. To report perioperative, pathologic, and oncologic outcomes of robot-assisted salvage nodal dissection (RASND) in patients with nodal recurrence after radical prostatectomy (RP). We retrospectively evaluated 16 patients affected by nodal recurrence following RP documented by positive positron emission tomography/computed tomography scan. Surgery was performed using DaVinci Si and Xi systems. A pelvic nodal dissection that included lymphatic stations overlying the external, internal, and common iliac vessels, the obturator fossa, and the presacral nodes was performed. In 13 (81.3%) patients a retroperitoneal lymph node dissection that included all nodal tissue located between the aortic bifurcation and the renal vessels was performed. Perioperative outcomes consisted of operative time, blood loss, length of hospital stay, and complications occurred within 30 d after surgery. Biochemical response (BR) was defined as a prostate-specific antigen level <0.2 ng/ml at 40 d after RASND. Median operative time, blood loss, and length of hospital stay were 210min, 250ml, and 3.5 d. The median number of nodes removed was 16.5. Positive lymph nodes were detected in 11 (68.8%) patients. Overall, four (25.0%) and five (31.2%) patients experienced intraoperative and postoperative complications, respectively. Overall, one (6.3%) and four (25.0%) patients had Clavien I and II complications within 30 d after RASND, respectively. Overall, five (33.3%) patients experienced BR after surgery. Our study is limited by the small cohort of patients evaluated and by the follow-up duration. RASND represents a feasible procedure in patients with nodal recurrence after RP and provides acceptable short-term oncologic outcomes, where one out of three patients experience BR immediately after surgery. Long-term data are needed to

  19. Ankle voluntary movement enhancement following robotic-assisted locomotor training in spinal cord injury.

    Science.gov (United States)

    Varoqui, Deborah; Niu, Xun; Mirbagheri, Mehdi M

    2014-03-31

    In incomplete spinal cord injury (iSCI), sensorimotor impairments result in severe limitations to ambulation. To improve walking capacity, physical therapies using robotic-assisted locomotor devices, such as the Lokomat, have been developed. Following locomotor training, an improvement in gait capabilities-characterized by increases in the over-ground walking speed and endurance-is generally observed in patients. To better understand the mechanisms underlying these improvements, we studied the effects of Lokomat training on impaired ankle voluntary movement, known to be an important limiting factor in gait for iSCI patients. Fifteen chronic iSCI subjects performed twelve 1-hour sessions of Lokomat training over the course of a month. The voluntary movement was qualified by measuring active range of motion, maximal velocity peak and trajectory smoothness for the spastic ankle during a movement from full plantar-flexion (PF) to full dorsi-flexion (DF) at the patient's maximum speed. Dorsi- and plantar-flexor muscle strength was quantified by isometric maximal voluntary contraction (MVC). Clinical assessments were also performed using the Timed Up and Go (TUG), the 10-meter walk (10MWT) and the 6-minute walk (6MWT) tests. All evaluations were performed both before and after the training and were compared to a control group of fifteen iSCI patients. After the Lokomat training, the active range of motion, the maximal velocity, and the movement smoothness were significantly improved in the voluntary movement. Patients also exhibited an improvement in the MVC for their ankle dorsi- and plantar-flexor muscles. In terms of functional activity, we observed an enhancement in the mobility (TUG) and the over-ground gait velocity (10MWT) with training. Correlation tests indicated a significant relationship between ankle voluntary movement performance and the walking clinical assessments. The improvements of the kinematic and kinetic parameters of the ankle voluntary movement

  20. Pathological confirmation of nerve-sparing types performed during robot-assisted radical prostatectomy (RARP).

    Science.gov (United States)

    Ko, Woo Jin; Hruby, Gregory W; Turk, Andrew T; Landman, Jaime; Badani, Ketan K

    2013-03-01

    WHAT'S KNOWN ON THE SUBJECT? AND WHAT DOES THE STUDY ADD?: Incremental nerve-sparing techniques (NSTs) improve postoperative erectile function after robot-assisted radical prostatectomy (RARP). However, there are no studies to date that histologically confirm the surgeon intended NST. Thus, in the present study, we histologically confirmed that the surgeon performed the nerve preservation as his intended NSTs during RARP. Also, we found that there was more variability in fascia width outcome on the left side compared with the right. Therefore, when performing nerve preservation on the surgeon's non-dominant side, we need to pay more close attention. To confirm that the surgeon achieved true intended histological nerve sparing during robot-assisted radical prostatectomy (RARP) by studying RP specimens. To aid the novice robotic surgeon to develop the skills of RARP. Between June 2008 and May 2009, 122 consecutive patients underwent RARP by a single surgeon (K.K.B.). The degree of nerve sparing (wide resection [WR], interfascial nerve sparing [ITE-NS], intrafascial nerve sparing [ITR-NS]) on both sides was recorded. The posterior sectors of RP specimens from distal, mid, and proximal parts were evaluated. Fascia width (FW) of each position in RP specimens were compared across nerve-sparing types (NSTs). FW was recorded at 15 ° intervals (3-9 o'clock position), measured as the distance between the outermost prostate gland and surgical margin. The slides were reviewed by an experienced uropathologist who was 'blinded' to the NST. In all, 93 men were included. The overall mean (sd) FW was the greatest in the order of WR, ITE-NS, and ITR-NS, at 2.42 (1.62), 1.71 (1.40) and 1.16 (1.08) mm, respectively (P ITE-NS, bilateral ITE-NS, ITE-NS/WR, and bilateral WR, respectively. To further validate and confirm these preliminary findings, additional studies involving multicentre cohorts would be required. The surgeon intended dissection and FW correlate, with ITR

  1. Development of a fixation device for robot assisted fracture reduction of femoral shaft fractures: a biomechanical study.

    Science.gov (United States)

    Weber-Spickschen, T S; Oszwald, M; Westphal, R; Krettek, C; Wahl, F; Gosling, T

    2010-01-01

    Robot assisted fracture reduction of femoral shaft fractures provides precise alignment while reducing the amount of intraoperative imaging. The connection between the robot and the fracture fragment should allow conventional intramedullary nailing, be minimally invasive and provide interim fracture stability. In our study we tested three different reduction tools: a conventional External Fixator, a Reposition-Plate and a Three-Point-Device with two variations (a 40 degrees and a 90 degrees version). We measured relative movements between the tools and the bone fragments in all translation and rotation planes. The Three-Point-Device 90 degrees showed the smallest average relative displacement and was the only device able to withstand the maximum applied load of 70 Nm without failure of any bone fragment. The Three-Point-Device 90 degrees complies with all the stipulated requirements and is a suitable interface for robot assisted fracture reduction of femoral shaft fractures.

  2. Development of a teaching tool for women with a gynecologic malignancy undergoing minimally invasive robotic-assisted surgery.

    Science.gov (United States)

    Castiglia, Luisa Luciani; Drummond, Nancy; Purden, Margaret A

    2011-08-01

    Women undergoing minimally invasive robotic-assisted surgery for a gynecologic malignancy have many questions and concerns related to the cancer diagnosis and surgery. The provision of information enhances coping with such illness-related challenges. A lack of print materials for these patients prompted the creation of a written teaching tool to improve informational support. A booklet was developed using guidelines for the design of effective patient education materials, including an iterative process of collaboration with healthcare providers and women who had undergone robotic-assisted surgery, as well as attention to readability. The 52-page booklet covers the trajectory of the woman's experience and includes the physical, psychosocial, and sexual aspects of recovery.

  3. Robot-assisted therapy for improving social interactions and activity participation among institutionalized older adults: a pilot study.

    Science.gov (United States)

    Sung, Huei-Chuan; Chang, Shu-Min; Chin, Mau-Yu; Lee, Wen-Li

    2015-03-01

    Animal-assisted therapy is gaining popularity as part of therapeutic activities for older adults in many long-term care facilities. However, concerns about dog bites, allergic responses to pets, disease, and insufficient available resources to care for a real pet have led to many residential care facilities to ban this therapy. There are situations where a substitute artificial companion, such as robotic pet, may serve as a better alternative. This pilot study used a one-group pre- and posttest design to evaluate the effect of a robot-assisted therapy for older adults. Sixteen eligible participants participated in the study and received a group robot-assisted therapy using a seal-like robot pet for 30 minutes twice a week for 4 weeks. All participants received assessments of their communication and interaction skills using the Assessment of Communication and Interaction Skills (ACIS-C) and activity participation using the Activity Participation Scale at baseline and at week 4. A total of 12 participants completed the study. Wilcoxon signed rank test showed that participants' communication and interaction skills (z = -2.94, P = 0.003) and activity participation (z = -2.66, P = 0.008) were significantly improved after receiving 4-week robot-assisted therapy. By interacting with a robot pet, such as Paro, the communication, interaction skills, and activity participation of the older adults can be improved. The robot-assisted therapy can be provided as a routine activity program and has the potential to improve social health of older adults in residential care facilities. Copyright © 2014 Wiley Publishing Asia Pty Ltd.

  4. Stratified analysis of 800 Asian patients after robot-assisted radical prostatectomy with a median 64 months of follow up.

    Science.gov (United States)

    Abdel Raheem, Ali; Kim, Dae Keun; Santok, Glen Denmer; Alabdulaali, Ibrahim; Chung, Byung Ha; Choi, Young Deuk; Rha, Koon Ho

    2016-09-01

    To report the 5-year oncological outcomes of robot-assisted radical prostatectomy from the largest series ever reported from Asia. A retrospective analysis of 800 Asian patients who were treated with robot-assisted radical prostatectomy from July 2005 to May 2010 in the Department of Urology and Urological Science Institute, Yonsei University College of Medicine, Seoul, Korea was carried out. The primary end-point was to evaluate the biochemical recurrence. The secondary end-point was to show the biochemical recurrence-free survival, metastasis-free survival and cancer-specific survival. A total of 197 (24.65%), 218 (27.3%), and 385 (48.1%) patients were classified as low-, intermediate- and high-risk patients according to the D'Amico risk stratification risk criteria, respectively. The median follow-up period was 64 months (interquartile range 28-71 months). The overall incidence of positive surgical margin was 36.6%. There was biochemical recurrence in 183 patients (22.9%), 38 patients (4.8%) developed distant metastasis and 24 patients (3%) died from prostate cancer. Actuarial biochemical recurrence-free survival, metastasis-free survival, and cancer-specific survival rates at 5 years were 76.4%, 94.6% and 96.7%, respectively. Positive lymph node was associated with lower 5-year biochemical recurrence-free survival (9.1%), cancer-specific survival (75.7%) and metastasis-free survival (61.9%) rates (P < 0.001). On multivariable analysis, among all the predictors, positive lymph node was the strongest predictor of biochemical recurrence, cancer-specific survival and metastasis-free survival (P < 0.001). Herein we report the largest robot-assisted radical prostatectomy series from Asia. Robot-assisted radical prostatectomy is confirmed to be an oncologically safe procedure that is able to provide effective 5-year cancer control, even in patients with high-risk disease. © 2016 The Japanese Urological Association.

  5. Recent trends in robot-assisted therapy environments to improve real-life functional performance after stroke

    OpenAIRE

    Johnson, Michelle J

    2006-01-01

    Abstract Upper and lower limb robotic tools for neuro-rehabilitation are effective in reducing motor impairment but they are limited in their ability to improve real world function. There is a need to improve functional outcomes after robot-assisted therapy. Improvements in the effectiveness of these environments may be achieved by incorporating into their design and control strategies important elements key to inducing motor learning and cerebral plasticity such as mass-practice, feedback, t...

  6. Robot-assisted surgery in a broader healthcare perspective: a difference-in-difference-based cost analysis of a national prostatectomy cohort.

    Science.gov (United States)

    Hyldgård, Vibe Bolvig; Laursen, Karin Rosenkilde; Poulsen, Johan; Søgaard, Rikke

    2017-07-21

    To estimate costs attributable to robot-assisted laparoscopic prostatectomy (RALP) as compared with open prostatectomy (OP) and laparoscopic prostatectomies (LP) in a National Health Service perspective. Register-based cohort study of 4309 consecutive patients who underwent prostatectomy from 2006 to 2013 (2241 RALP, 1818 OP and 250 LP). Patients were followed from 12 months before to 12 months after prostatectomy with respect to service use in primary care (general practitioners, therapists, specialists etc) and hospitals (inpatient and outpatient activity related to prostatectomy and comorbidity). Tariffs of the activity-based remuneration system for primary care and the Diagnosis-Related Grouping case-mix system for hospital-based care were used to value service use. Costs attributable to RALP were estimated using a difference-in-difference analytical approach and adjusted for patient-level and hospital-level risk selection using multilevel regression. No significant effect of RALP on resource-use was observed except for a marginally lower use of primary care and fewer bed days as compared with OP (not LP). The overall cost consequence of RALP was estimated at an additional €2459 (95% CI 1377 to 3540, p=0.003) as compared with OP and an additional €3860 (95% CI 559 to 7160, p=0.031) as compared with LP, mainly due to higher cost intensity during the index admissions. In this study from the Danish context, the use of RALP generates a factor 1.3 additional cost when compared with OP and a factor 1.6 additional cost when compared with LP, on average, based on 12 months follow-up. The policy interpretation is that the use of robots for prostatectomy should be driven by clinical superiority and that formal effectiveness analysis is required to determine whether the current and eventual new purchasing of robot capacity is best used for prostatectomy. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights

  7. LAPAROSCOPIC PANCREATIC RESECTION. FROM ENUCLEATION TO PANCREATODUODENECTOMY. 11-YEAR EXPERIENCE

    Directory of Open Access Journals (Sweden)

    Marcel Autran Cesar MACHADO

    Full Text Available Context Our experience with laparoscopic pancreatic resection began in 2001. During initial experience, laparoscopy was reserved for selected cases. With increasing experience more complex laparoscopic procedures such as central pancreatectomy and pancreatoduodenectomies were performed. Objectives The aim of this paper is to review our personal experience with laparoscopic pancreatic resection over 11-year period. Methods All patients who underwent laparoscopic pancreatic resection from 2001 through 2012 were reviewed. Preoperative data included age, gender, and indication for surgery. Intraoperative variables included operative time, bleeding, blood transfusion. Diagnosis, tumor size, margin status were determined from final pathology reports. Results Since 2001, 96 patients underwent laparoscopic pancreatectomy. Median age was 55 years old. 60 patients were female and 36 male. Of these, 88 (91.6% were performed totally laparoscopic; 4 (4.2% needed hand-assistance, 1 robotic assistance. Three patients were converted. Four patients needed blood transfusion. Operative time varied according type of operation. Mortality was nil but morbidity was high, mainly due to pancreatic fistula (28.1%. Sixty-one patients underwent distal pancreatectomy, 18 underwent pancreatic enucleation, 7 pylorus-preserving pancreatoduodenectomies, 5 uncinate process resection, 3 central and 2 total pancreatectomies. Conclusions Laparoscopic resection of the pancreas is a reality. Pancreas sparing techniques, such as enucleation, resection of uncinate process and central pancreatectomy, should be used to avoid exocrine and/or endocrine insufficiency that could be detrimental to the patient's quality of life. Laparoscopic pancreatoduodenectomy is a safe operation but should be performed in specialized centers by highly skilled laparoscopic surgeons.

  8. Reduction of freezing of gait in Parkinson's disease by repetitive robot-assisted treadmill training: a pilot study

    Directory of Open Access Journals (Sweden)

    Friedman Joseph H

    2010-10-01

    Full Text Available Abstract Background Parkinson's disease is a chronic, neurodegenerative disease characterized by gait abnormalities. Freezing of gait (FOG, an episodic inability to generate effective stepping, is reported as one of the most disabling and distressing parkinsonian symptoms. While there are no specific therapies to treat FOG, some external physical cues may alleviate these types of motor disruptions. The purpose of this study was to examine the potential effect of continuous physical cueing using robot-assisted sensorimotor gait training on reducing FOG episodes and improving gait. Methods Four individuals with Parkinson's disease and FOG symptoms received ten 30-minute sessions of robot-assisted gait training (Lokomat to facilitate repetitive, rhythmic, and alternating bilateral lower extremity movements. Outcomes included the FOG-Questionnaire, a clinician-rated video FOG score, spatiotemporal measures of gait, and the Parkinson's Disease Questionnaire-39 quality of life measure. Results All participants showed a reduction in FOG both by self-report and clinician-rated scoring upon completion of training. Improvements were also observed in gait velocity, stride length, rhythmicity, and coordination. Conclusions This pilot study suggests that robot-assisted gait training may be a feasible and effective method of reducing FOG and improving gait. Videotaped scoring of FOG has the potential advantage of providing additional data to complement FOG self-report.

  9. Predicting Functional Recovery in Chronic Stroke Rehabilitation Using Event-Related Desynchronization-Synchronization during Robot-Assisted Movement

    Directory of Open Access Journals (Sweden)

    Marco Caimmi

    2016-01-01

    Full Text Available Although rehabilitation robotics seems to be a promising therapy in the rehabilitation of the upper limb in stroke patients, consensus is still lacking on its additive effects. Therefore, there is a need for determining the possible success of robotic interventions on selected patients, which in turn determine the necessity for new investigating instruments supporting the treatment decision-making process and customization. The objective of the work presented in this preliminary study was to verify that fully robot assistance would not affect the physiological oscillatory cortical activity related to a functional movement in healthy subjects. Further, the clinical results following the robotic treatment of a chronic stroke patient, who positively reacted to the robotic intervention, were analyzed and discussed. First results show that there is no difference in EEG activation pattern between assisted and no-assisted movement in healthy subjects. Even more importantly, the patient’s pretreatment EEG activation pattern in no-assisted movement was completely altered, while it recovered to a quasi-physiological one in robot-assisted movement. The functional improvement following treatment was large. Using pretreatment EEG recording during robot-assisted movement might be a valid approach to assess the potential ability of the patient for recovering.

  10. Predicting Functional Recovery in Chronic Stroke Rehabilitation Using Event-Related Desynchronization-Synchronization during Robot-Assisted Movement

    Science.gov (United States)

    Gramigna, Cristina; Franceschetti, Silvana

    2016-01-01

    Although rehabilitation robotics seems to be a promising therapy in the rehabilitation of the upper limb in stroke patients, consensus is still lacking on its additive effects. Therefore, there is a need for determining the possible success of robotic interventions on selected patients, which in turn determine the necessity for new investigating instruments supporting the treatment decision-making process and customization. The objective of the work presented in this preliminary study was to verify that fully robot assistance would not affect the physiological oscillatory cortical activity related to a functional movement in healthy subjects. Further, the clinical results following the robotic treatment of a chronic stroke patient, who positively reacted to the robotic intervention, were analyzed and discussed. First results show that there is no difference in EEG activation pattern between assisted and no-assisted movement in healthy subjects. Even more importantly, the patient's pretreatment EEG activation pattern in no-assisted movement was completely altered, while it recovered to a quasi-physiological one in robot-assisted movement. The functional improvement following treatment was large. Using pretreatment EEG recording during robot-assisted movement might be a valid approach to assess the potential ability of the patient for recovering. PMID:27057546

  11. Hand Passive Mobilization Performed with Robotic Assistance: Acute Effects on Upper Limb Perfusion and Spasticity in Stroke Survivors

    Directory of Open Access Journals (Sweden)

    Massimiliano Gobbo

    2017-01-01

    Full Text Available This single arm pre-post study aimed at evaluating the acute effects induced by a single session of robot-assisted passive hand mobilization on local perfusion and upper limb (UL function in poststroke hemiparetic participants. Twenty-three patients with subacute or chronic stroke received 20 min passive mobilization of the paretic hand with robotic assistance. Near-infrared spectroscopy (NIRS was used to detect changes in forearm tissue perfusion. Muscle tone of the paretic UL was assessed by the Modified Ashworth Scale (MAS. Symptoms concerning UL heaviness, joint stiffness, and pain were evaluated as secondary outcomes by self-reporting. Significant (p=0.014 improvements were found in forearm perfusion when all fingers were mobilized simultaneously. After the intervention, MAS scores decreased globally, being the changes statistically significant for the wrist (from 1.6±1.0 to 1.1±1.0; p=0.001 and fingers (from 1.2±1.1 to 0.7±0.9; p=0.004. Subjects reported decreased UL heaviness and stiffness after treatment, especially for the hand, as well as diminished pain when present. This study supports novel evidence that hand robotic assistance promotes local UL circulation changes, may help in the management of spasticity, and acutely alleviates reported symptoms of heaviness, stiffness, and pain in subjects with poststroke hemiparesis. This opens new scenarios for the implications in everyday clinical practice. Clinical Trial Registration Number is NCT03243123.

  12. Changes in skeletal muscle perfusion and spasticity in patients with poststroke hemiparesis treated by robotic assistance (Gloreha) of the hand.

    Science.gov (United States)

    Bissolotti, Luciano; Villafañe, Jorge Hugo; Gaffurini, Paolo; Orizio, Claudio; Valdes, Kristin; Negrini, Stefano

    2016-03-01

    [Purpose] The purpose of this case series was to determine the effects of robot-assisted hand rehabilitation with a Gloreha device on skeletal muscle perfusion, spasticity, and motor function in subjects with poststroke hemiparesis. [Subjects and Methods] Seven patients, 2 women and 5 men (mean ± SD age: 60.5 ±6.3 years), with hemiparesis (>6 months poststroke), received passive mobilization of the hand with a Gloreha (Idrogenet, Italy), device (30 min per day; 3 sessions a week for 3 weeks). The outcome measures were the total hemoglobin profiles and tissue oxygenation index (TOI) in the muscle tissue evaluated through near-infrared spectroscopy. The Motricity Index and modified Ashworth Scale for upper limb muscles were used to assess mobility of the upper extremity. [Results] Robotic assistance reduced spasticity after the intervention by 68.6% in the upper limb. The Motricity Index was unchanged in these patients after treatment. Regarding changes in muscle perfusion, significant improvements were found in total hemoglobin. There were significant differences between the pre- and posttreatment modified Ashworth scale. [Conclusion] The present work provides novel evidence that robotic assistance of the hand induced changes in local muscle blood flow and oxygen supply, diminished spasticity, and decreased subject-reported symptoms of heaviness and stiffness in subjects with post-stroke hemiparesis.

  13. Hand Passive Mobilization Performed with Robotic Assistance: Acute Effects on Upper Limb Perfusion and Spasticity in Stroke Survivors.

    Science.gov (United States)

    Gobbo, Massimiliano; Gaffurini, Paolo; Vacchi, Laura; Lazzarini, Sara; Villafane, Jorge; Orizio, Claudio; Negrini, Stefano; Bissolotti, Luciano

    2017-01-01

    This single arm pre-post study aimed at evaluating the acute effects induced by a single session of robot-assisted passive hand mobilization on local perfusion and upper limb (UL) function in poststroke hemiparetic participants. Twenty-three patients with subacute or chronic stroke received 20 min passive mobilization of the paretic hand with robotic assistance. Near-infrared spectroscopy (NIRS) was used to detect changes in forearm tissue perfusion. Muscle tone of the paretic UL was assessed by the Modified Ashworth Scale (MAS). Symptoms concerning UL heaviness, joint stiffness, and pain were evaluated as secondary outcomes by self-reporting. Significant ( p = 0.014) improvements were found in forearm perfusion when all fingers were mobilized simultaneously. After the intervention, MAS scores decreased globally, being the changes statistically significant for the wrist (from 1.6 ± 1.0 to 1.1 ± 1.0; p = 0.001) and fingers (from 1.2 ± 1.1 to 0.7 ± 0.9; p = 0.004). Subjects reported decreased UL heaviness and stiffness after treatment, especially for the hand, as well as diminished pain when present. This study supports novel evidence that hand robotic assistance promotes local UL circulation changes, may help in the management of spasticity, and acutely alleviates reported symptoms of heaviness, stiffness, and pain in subjects with poststroke hemiparesis. This opens new scenarios for the implications in everyday clinical practice. Clinical Trial Registration Number is NCT03243123.

  14. Robot-Assisted Excision of a Pararectal Gastrointestinal Stromal Tumor in a Patient with Previous Ileal Neobladder

    Directory of Open Access Journals (Sweden)

    A. Ploumidis

    2014-01-01

    Full Text Available Gastrointestinal stromal tumors (GISTs are the most frequent mesenchymal tumors of the gastrointestinal tract with surgical resection remaining the cornerstone of therapy. Pararectal lesions are considered to be technically difficult and pose in some cases a challenge. We report, to the best of our knowledge, the first robotic-assisted pararectal GIST excision. A 43-year-old man was referred to our center with pararectal GIST recurrence, despite treatment with targeted therapy. Eleven years ago, he underwent extensive abdominal surgery including cystoprostatectomy with ileal neobladder diversion due to GIST resection in the rectoprostatic space. Robot-assisted surgical resection was successfully performed without the need for temporary colostomy. The postoperative course of the patient was uneventful, and the pathology report confirmed a GIST recurrence with negative surgical margins and pelvic lymph nodes free of any tumor. Robotic-assisted pelvic surgery can be extended to incorporate excision of pararectal GISTs, as a safe, less invasive surgical alternative with promising oncological results and minimal injury to adjacent structures.

  15. Individual finger synchronized robot-assisted hand rehabilitation in subacute to chronic stroke: a prospective randomized clinical trial of efficacy.

    Science.gov (United States)

    Hwang, Chang Ho; Seong, Jin Wan; Son, Dae-Sik

    2012-08-01

    To evaluate individual finger synchronized robot-assisted hand rehabilitation in stroke patients. Prospective parallel group randomized controlled clinical trial. The study recruited patients who were ≥18 years old, more than three months post stroke, showed limited index finger movement and had weakened and impaired hand function. Patients with severe sensory loss, spasticity, apraxia, aphasia, disabling hand disease, impaired consciousness or depression were excluded. Patients received either four weeks (20 sessions) of active robot-assisted intervention (the FTI (full-term intervention) group, 9 patients) or two weeks (10 sessions) of early passive therapy followed by two weeks (10 sessions) of active robot-assisted intervention (the HTI (half-term intervention) group, 8 patients). Patients underwent arm function assessments prior to therapy (baseline), and at 2, 4 and 8 weeks after starting therapy. Compared to baseline, both the FTI and HTI groups showed improved results for the Jebsen Taylor test, the wrist and hand subportion of the Fugl-Meyer arm motor scale, active movement of the 2nd metacarpophalangeal joint, grasping, and pinching power (P vs. 46.4 ± 37.4) and wrist and hand subportion of the Fugl-Meyer arm motor scale (4.3 ± 1.9 vs. 3.4 ± 2.5) after eight weeks. A four-week rehabilitation using a novel robot that provides individual finger synchronization resulted in a dose-dependent improvement in hand function in subacute to chronic stroke patients.

  16. Force Modeling, Identification, and Feedback Control of Robot-Assisted Needle Insertion: A Survey of the Literature

    Directory of Open Access Journals (Sweden)

    Chongjun Yang

    2018-02-01

    Full Text Available Robot-assisted surgery is of growing interest in the surgical and engineering communities. The use of robots allows surgery to be performed with precision using smaller instruments and incisions, resulting in shorter healing times. However, using current technology, an operator cannot directly feel the operation because the surgeon-instrument and instrument-tissue interaction force feedbacks are lost during needle insertion. Advancements in force feedback and control not only help reduce tissue deformation and needle deflection but also provide the surgeon with better control over the surgical instruments. The goal of this review is to summarize the key components surrounding the force feedback and control during robot-assisted needle insertion. The literature search was conducted during the middle months of 2017 using mainstream academic search engines with a combination of keywords relevant to the field. In total, 166 articles with valuable contents were analyzed and grouped into five related topics. This survey systemically summarizes the state-of-the-art force control technologies for robot-assisted needle insertion, such as force modeling, measurement, the factors that influence the interaction force, parameter identification, and force control algorithms. All studies show force control is still at its initial stage. The influence factors, needle deflection or planning remain open for investigation in future.

  17. Facilitators and barriers to adopting robotic-assisted surgery: contextualizing the unified theory of acceptance and use of technology.

    Directory of Open Access Journals (Sweden)

    Christine Benmessaoud

    Full Text Available Robotic-assisted surgical techniques are not yet well established among surgeon practice groups beyond a few surgical subspecialties. To help identify the facilitators and barriers to their adoption, this belief-elicitation study contextualized and supplemented constructs of the unified theory of acceptance and use of technology (UTAUT in robotic-assisted surgery. Semi-structured individual interviews were conducted with 21 surgeons comprising two groups: users and nonusers. The main facilitators to adoption were Perceived Usefulness and Facilitating Conditions among both users and nonusers, followed by Attitude Toward Using Technology among users and Extrinsic Motivation among nonusers. The three main barriers to adoption for both users and nonusers were Perceived Ease of Use and Complexity, Perceived Usefulness, and Perceived Behavioral Control. This study's findings can assist surgeons, hospital and medical school administrators, and other policy makers on the proper adoption of robotic-assisted surgery and can guide future research on the development of theories and framing of hypotheses.

  18. Force Modeling, Identification, and Feedback Control of Robot-Assisted Needle Insertion: A Survey of the Literature.

    Science.gov (United States)

    Yang, Chongjun; Xie, Yu; Liu, Shuang; Sun, Dong

    2018-02-12

    Robot-assisted surgery is of growing interest in the surgical and engineering communities. The use of robots allows surgery to be performed with precision using smaller instruments and incisions, resulting in shorter healing times. However, using current technology, an operator cannot directly feel the operation because the surgeon-instrument and instrument-tissue interaction force feedbacks are lost during needle insertion. Advancements in force feedback and control not only help reduce tissue deformation and needle deflection but also provide the surgeon with better control over the surgical instruments. The goal of this review is to summarize the key components surrounding the force feedback and control during robot-assisted needle insertion. The literature search was conducted during the middle months of 2017 using mainstream academic search engines with a combination of keywords relevant to the field. In total, 166 articles with valuable contents were analyzed and grouped into five related topics. This survey systemically summarizes the state-of-the-art force control technologies for robot-assisted needle insertion, such as force modeling, measurement, the factors that influence the interaction force, parameter identification, and force control algorithms. All studies show force control is still at its initial stage. The influence factors, needle deflection or planning remain open for investigation in future.

  19. Robot-Assisted Body-Weight-Supported Treadmill Training in Gait Impairment in Multiple Sclerosis Patients: A Pilot Study.

    Science.gov (United States)

    Łyp, Marek; Stanisławska, Iwona; Witek, Bożena; Olszewska-Żaczek, Ewelina; Czarny-Działak, Małgorzata; Kaczor, Ryszard

    2018-02-13

    This study deals with the use of a robot-assisted body-weight-supported treadmill training in multiple sclerosis (MS) patients with gait dysfunction. Twenty MS patients (10 men and 10 women) of the mean of 46.3 ± 8.5 years were assigned to a six-week-long training period with the use of robot-assisted treadmill training of increasing intensity of the Lokomat type. The outcome measure consisted of the difference in motion-dependent torque of lower extremity joint muscles after training compared with baseline before training. We found that the training uniformly and significantly augmented the torque of both extensors and flexors of the hip and knee joints. The muscle power in the lower limbs of SM patients was improved, leading to corrective changes of disordered walking movements, which enabled the patients to walk with less effort and less assistance of care givers. The torque augmentation could have its role in affecting the function of the lower extremity muscle groups during walking. The results of this pilot study suggest that the robot-assisted body-weight-supported treadmill training may be a potential adjunct measure in the rehabilitation paradigm of 'gait reeducation' in peripheral neuropathies.

  20. On the Use of the Humanoid Bioloid System for Robot-Assisted Transcription of Mexican Spanish Speech

    Directory of Open Access Journals (Sweden)

    Santiago-Omar Caballero-Morales

    2015-12-01

    Full Text Available Within the context of service robotics (SR, the development of assistive technologies has become an important research field. However, the accomplishment of assistive tasks requires precise and fine control of the mechanic systems that integrate the robotic entity. Among the most challenging tasks in robot control, the handwriting task (transcription is of particular interest due to the fine control required to draw single and multiple alphabet characters to express words and sentences. For language learning activities, robot-assisted speech transcription can motivate the student to practice pronunciation and writing tasks in a dynamic environment. Hence, this paper is aimed to provide the techniques and models to accomplish accurate robot-assisted transcription of Spanish speech. The transcriptor is integrated by a multi-user speech recognizer for continuous speech and the kinematic models for the Mexican Spanish alphabet characters. The Bioloid system with the standard humanoid configuration and no special modifications or tools was considered for implementation. Particularly, the proposed transcriptor could perform the handwriting task with the Bioloid’s two two DOF (degrees-of-freedom arms. This enabled writing of one-line short and long sentences with small alphabet characters (width <1.0 cm. It is expected that the technique and models that integrate the transcriptor can provide support for the development of robot-assisted language learning activities for children and young adults.

  1. Intra-Abdominal Cooling System Limits Ischemia-Reperfusion Injury During Robot-Assisted Renal Transplantation.

    Science.gov (United States)

    Meier, R P H; Piller, V; Hagen, M E; Joliat, C; Buchs, J-B; Nastasi, A; Ruttimann, R; Buchs, N C; Moll, S; Vallée, J-P; Lazeyras, F; Morel, P; Bühler, L

    2018-01-01

    Robot-assisted kidney transplantation is feasible; however, concerns have been raised about possible increases in warm ischemia times. We describe a novel intra-abdominal cooling system to continuously cool the kidney during the procedure. Porcine kidneys were procured by standard open technique. Groups were as follows: Robotic renal transplantation with (n = 11) and without (n = 6) continuous intra-abdominal cooling and conventional open technique with intermittent 4°C saline cooling (n = 6). Renal cortex temperature, magnetic resonance imaging, and histology were analyzed. Robotic renal transplantation required a longer anastomosis time, either with or without the cooling system, compared to the open approach (70.4 ± 17.7 min and 74.0 ± 21.5 min vs. 48.7 ± 11.2 min, p-values system compared to the open approach group (6.5 ± 3.1°C vs. 22.5 ± 6.5°C; p = 0.001) or compared to the robotic group without the cooling system (28.7 ± 3.3°C; p system that suppresses the noncontrolled rewarming of donor kidneys during the transplant procedure and prevents ischemia-reperfusion injuries. © 2017 The Authors. American Journal of Transplantation published by Wiley Periodicals, Inc. on behalf of American Society of Transplant Surgeons.

  2. New software tools for enhanced precision in robot-assisted laser phonomicrosurgery.

    Science.gov (United States)

    Dagnino, Giulio; Mattos, Leonardo S; Caldwell, Darwin G

    2012-01-01

    This paper describes a new software package created to enhance precision during robot-assisted laser phonomicrosurgery procedures. The new software is composed of three tools for camera calibration, automatic tumor segmentation, and laser tracking. These were designed and developed to improve the outcome of this demanding microsurgical technique, and were tested herein to produce quantitative performance data. The experimental setup was based on the motorized laser micromanipulator created by Istituto Italiano di Tecnologia and the experimental protocols followed are fully described in this paper. The results show the new tools are robust and effective: The camera calibration tool reduced residual errors (RMSE) to 0.009 ± 0.002 mm under 40× microscope magnification; the automatic tumor segmentation tool resulted in deep lesion segmentations comparable to manual segmentations (RMSE= 0.160 ± 0.028 mm under 40× magnification); and the laser tracker tool proved to be reliable even during cutting procedures (RMSE= 0.073 ± 0.023 mm under 40× magnification). These results demonstrate the new software package can provide excellent improvements to the previous microsurgical system, leading to important enhancements in surgical outcome.

  3. The Impact of Training Residents on the Outcome of Robotic-Assisted Sacrocolpopexy

    Directory of Open Access Journals (Sweden)

    Mohamed A. Bedaiwy

    2012-01-01

    Full Text Available Objective. To evaluate the surgical outcomes of robotic-assisted sacrocolpopexy (RASCP before and after the incorporation of hands-on training for urology and gynecology residents. Study Design. Forty-one patients underwent RASCP between December 2008 and March 2010 with one surgeon. RASCP was performed in the context of surgical repair of complex pelvic organ prolapse and/or stress urinary incontinence. The first 20 cases (group I were performed exclusively by the attending surgeon. In the last 21 cases (group II, the urology resident performed a 50% or more of the RASCP while the gynecology resident performed the supracervical hysterectomy. The primary outcome measure was vaginal vault support at 24 weeks postoperatively based on pelvic organ prolapse quantification (POP-Q. Results. Mean ± SD operative time for the entire surgery including RASCP was 282.3±51.3 min and median EBL was 83.1±50.4 mL. Patient demographics and stage of disease did not differ between groups. Procedure time, PACU time, blood loss, and intraoperative complications were similar between groups. Follow-up POP-Q evaluations demonstrated significant correction of all points on vaginal examination for both groups (P<0.001. Conclusions. Incorporation of resident training during RASCP allows teaching of robotic surgery techniques in an effective manner without prolonging operative time or affecting the overall surgical outcome.

  4. Experimental evaluation of magnified haptic feedback for robot-assisted needle insertion and palpation.

    Science.gov (United States)

    Meli, Leonardo; Pacchierotti, Claudio; Prattichizzo, Domenico

    2017-12-01

    Haptic feedback has been proven to play a key role in enhancing the performance of teleoperated medical procedures. However, due to safety issues, commercially-available medical robots do not currently provide the clinician with haptic feedback. This work presents the experimental evaluation of a teleoperation system for robot-assisted medical procedures able to provide magnified haptic feedback to the clinician. Forces registered at the operating table are magnified and provided to the clinician through a 7-DoF haptic interface. The same interface is also used to control the motion of a 6-DoF slave robotic manipulator. The safety of the system is guaranteed by a time-domain passivity-based control algorithm. Two experiments were carried out on stiffness discrimination (during palpation and needle insertion) and one experiment on needle guidance. Our haptic-enabled teleoperation system improved the performance with respect to direct hand interaction of 80%, 306%, and 27% in stiffness discrimination through palpation, stiffness discrimination during needle insertion, and guidance, respectively. Copyright © 2017 John Wiley & Sons, Ltd.

  5. Does training of fellows affect peri-operative outcomes of robot-assisted partial nephrectomy?

    Science.gov (United States)

    Khene, Zine-Eddine; Peyronnet, Benoit; Bosquet, Elise; Pradère, Benjamin; Robert, Corentin; Fardoun, Tarek; Kammerer-Jacquet, Solène-Florence; Verhoest, Grégory; Rioux-Leclercq, Nathalie; Mathieu, Romain; Bensalah, Karim

    2017-10-01

    To evaluate the impact of fellows' involvement on the peri-operative outcomes of robot-assisted partial nephrectomy (RAPN). We analysed 216 patients who underwent RAPN for a small renal tumour. We stratified our cohort into two groups according to the involvement of a fellow surgeon during the procedure: expert surgeon operating alone (expert group) and fellow operating under the supervision of the expert surgeon (fellow group). Peri-operative data were compared between the two groups. Linear and logistic regression analyses were performed to assess the impact of fellows' involvement on peri-operative and postoperative outcomes. Trifecta and margins ischaemia complications (MIC) score achievement rates were used to assess the quality of surgery in both the expert and fellow groups. Trifecta was defined as a combination of warm ischaemia time negative surgical margins and no peri-operative complications. MIC score was defined as negative surgical margins, ischaemia time Training fellows to perform RAPN is associated with longer operating time and WIT but does not appear to compromise other peri-operative outcomes. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  6. The Evolution of Image-Free Robotic Assistance in Unicompartmental Knee Arthroplasty.

    Science.gov (United States)

    Lonner, Jess H; Moretti, Vincent M

    2016-01-01

    Semiautonomous robotic technology has been introduced to optimize accuracy of bone preparation, implant positioning, and soft tissue balance in unicompartmental knee arthroplasty (UKA), with the expectation that there will be a resultant improvement in implant durability and survivorship. Currently, roughly one-fifth of UKAs in the US are being performed with robotic assistance, and it is anticipated that there will be substantial growth in market penetration of robotics over the next decade. First-generation robotic technology improved substantially implant position compared to conventional methods; however, high capital costs, uncertainty regarding the value of advanced technologies, and the need for preoperative computed tomography (CT) scans were barriers to broader adoption. Newer image-free semiautonomous robotic technology optimizes both implant position and soft tissue balance, without the need for preoperative CT scans and with pricing and portability that make it suitable for use in an ambulatory surgery center setting, where approximately 40% of these systems are currently being utilized. This article will review the robotic experience for UKA, including rationale, system descriptions, and outcomes.

  7. Retroperitoneal approach for robot-assisted partial nephrectomy: technique and early outcomes

    Directory of Open Access Journals (Sweden)

    A. Porreca

    Full Text Available ABSTRACT Objectives The aim of our study is to present early outcomes of our series of retroperitoneal-RAPN (Robot Assisted Partial Nephrectomy. Materials and methods From September 2010 until December 2015, we performed 81 RAPN procedures (44 at left kidney and 37 at right. Average size was 3cm (1-9. Average PADUA score 7.1 (5-10. Average surgical time (overall and only robot time, ischemia time, blood loss, pathological stage, complications and hospital stay have been recorded. Results All of the cases were completed successfully without any operative complication or surgical conversion. Average surgical time was 177 minutes (75-340. Operative time was 145 minutes (80-300, overall blood loss was 142cc (60-310cc. In 30 cases the pedicle was late clamped with an average ischemia time of 4 minutes (2-7. None of the patient had positive surgical margins at definitive histology (49pT1a, 12pT1b, 3pT2a, 2pT3a. Hospital stay was 3 days (2-7. Conclusions The retroperitoneal robotic partial nephrectomy approach is safe and allows treatment of even quite complex tumors. It also combines the already well known advantages guaranteed by the da Vinci® robotic surgical system, with the advantages of the retroperitoneoscopic approach.

  8. da Vinci robot-assisted keyhole neurosurgery: a cadaver study on feasibility and safety.

    Science.gov (United States)

    Marcus, Hani J; Hughes-Hallett, Archie; Cundy, Thomas P; Yang, Guang-Zhong; Darzi, Ara; Nandi, Dipankar

    2015-04-01

    The goal of this cadaver study was to evaluate the feasibility and safety of da Vinci robot-assisted keyhole neurosurgery. Several keyhole craniotomies were fashioned including supraorbital subfrontal, retrosigmoid and supracerebellar infratentorial. In each case, a simple durotomy was performed, and the flap was retracted. The da Vinci surgical system was then used to perform arachnoid dissection towards the deep-seated intracranial cisterns. It was not possible to simultaneously pass the 12-mm endoscope and instruments through the keyhole craniotomy in any of the approaches performed, limiting visualization. The articulated instruments provided greater dexterity than existing tools, but the instrument arms could not be placed in parallel through the keyhole craniotomy and, therefore, could not be advanced to the deep cisterns without significant clashing. The da Vinci console offered considerable ergonomic advantages over the existing operating room arrangement, allowing the operating surgeon to remain non-sterile and seated comfortably throughout the procedure. However, the lack of haptic feedback was a notable limitation. In conclusion, while robotic platforms have the potential to greatly enhance the performance of transcranial approaches, there is strong justification for research into next-generation robots, better suited to keyhole neurosurgery.

  9. A Vision-Based Approach for Estimating Contact Forces: Applications to Robot-Assisted Surgery

    Directory of Open Access Journals (Sweden)

    C. W. Kennedy

    2005-01-01

    Full Text Available The primary goal of this paper is to provide force feedback to the user using vision-based techniques. The approach presented in this paper can be used to provide force feedback to the surgeon for robot-assisted procedures. As proof of concept, we have developed a linear elastic finite element model (FEM of a rubber membrane whereby the nodal displacements of the membrane points are measured using vision. These nodal displacements are the input into our finite element model. In the first experiment, we track the deformation of the membrane in real-time through stereovision and compare it with the actual deformation computed through forward kinematics of the robot arm. On the basis of accurate deformation estimation through vision, we test the physical model of a membrane developed through finite element techniques. The FEM model accurately reflects the interaction forces on the user console when the interaction forces of the robot arm with the membrane are compared with those experienced by the surgeon on the console through the force feedback device. In the second experiment, the PHANToM haptic interface device is used to control the Mitsubishi PA-10 robot arm and interact with the membrane in real-time. Image data obtained through vision of the deformation of the membrane is used as the displacement input for the FEM model to compute the local interaction forces which are then displayed on the user console for providing force feedback and hence closing the loop.

  10. Tracked "Pick-Up" Ultrasound for Robot-Assisted Minimally Invasive Surgery.

    Science.gov (United States)

    Schneider, Caitlin; Nguan, Christopher; Rohling, Robert; Salcudean, Septimiu

    2016-02-01

    We present a novel "pick-up" ultrasound transducer for intraabdominal robot-assisted minimally invasive surgery. Such a "pick-up" ultrasound transducer is inserted through an abdominal incision at the beginning of the procedure and remains in the abdominal cavity throughout, eliminating the need for a dedicated port or a patient bedside surgical assistant. The transducer has a handle that can be grasped in a repeatable manner using a da Vinci Prograsp tool, allowing the transducer to be accurately manipulated by the surgeon using the da Vinci Robot. This is one way to enable 3-D tracking of the transducer, and, thus, mapping of the vasculature. The 3-D vascular images can be used to register preoperative CT to intraoperative camera images. To demonstrate the feasibility of the approach, we use an ultrasound vessel phantom to register a CT surface model to extracted ultrasound vessel models. The 3-D vascular phantom images are generated by segmenting B-mode images and tracking the pick-up ultrasound transducer with the da Vinci kinematics, internal electromagnetic sensor, or visible fiducials suitable for camera tracking. Reconstruction results using da Vinci kinematics for tracking give a target registration error of 5.4 ± 1.7 mm.

  11. Carbon footprint of robotically-assisted laparoscopy, laparoscopy and laparotomy: a comparison.

    Science.gov (United States)

    Woods, Demetrius L; McAndrew, Thomas; Nevadunsky, Nicole; Hou, June Y; Goldberg, Gary; Yi-Shin Kuo, Dennis; Isani, Sara

    2015-12-01

    To date there have been no comprehensive, comparative assessments of the environmental impact of surgical modalities. Our study seeks to quantify and compare the total greenhouse gas emissions, or 'carbon footprint', attributable to three surgical modalities. A review of 150 staging procedures, employing laparotomy (LAP), conventional laparoscopy (LSC) or robotically-assisted laparoscopy (RA-LSC), was performed. The solid waste generated (kg) and energy consumed (kWh) during each case were quantified and converted into their equivalent mass of carbon dioxide (kg CO(2) e) release into the environment. The carbon footprint is the sum of the waste production and energy consumption during each surgery (kg CO(2) e). The total carbon footprint of a RA-LSC procedure is 40.3 kg CO(2) e/patient (p < 0.01). This represents a 38% increase over that of LSC (29.2 kg CO(2) e/patient; p < 0.01) and a 77% increase over LAP (22.7 kg CO(2) e/patient; p < 0.01). Our results provide clinicians, administrators and policy-makers with knowledge of the environmental impact of their decisions to facilitate adoption of sustainable practices. Copyright © 2015 John Wiley & Sons, Ltd.

  12. A vision-based system for fast and accurate laser scanning in robot-assisted phonomicrosurgery.

    Science.gov (United States)

    Dagnino, Giulio; Mattos, Leonardo S; Caldwell, Darwin G

    2015-02-01

    Surgical quality in phonomicrosurgery can be improved by open-loop laser control (e.g., high-speed scanning capabilities) with a robust and accurate closed-loop visual servoing systems. A new vision-based system for laser scanning control during robot-assisted phonomicrosurgery was developed and tested. Laser scanning was accomplished with a dual control strategy, which adds a vision-based trajectory correction phase to a fast open-loop laser controller. The system is designed to eliminate open-loop aiming errors caused by system calibration limitations and by the unpredictable topology of real targets. Evaluation of the new system was performed using CO(2) laser cutting trials on artificial targets and ex-vivo tissue. This system produced accuracy values corresponding to pixel resolution even when smoke created by the laser-target interaction clutters the camera view. In realistic test scenarios, trajectory following RMS errors were reduced by almost 80 % with respect to open-loop system performances, reaching mean error values around 30 μ m and maximum observed errors in the order of 60 μ m. A new vision-based laser microsurgical control system was shown to be effective and promising with significant positive potential impact on the safety and quality of laser microsurgeries.

  13. Preliminary analysis of force-torque measurements for robot-assisted fracture surgery.

    Science.gov (United States)

    Georgilas, Ioannis; Dagnino, Giulio; Tarassoli, Payam; Atkins, Roger; Dogramadzi, Sanja

    2015-08-01

    Our group at Bristol Robotics Laboratory has been working on a new robotic system for fracture surgery that has been previously reported [1]. The robotic system is being developed for distal femur fractures and features a robot that manipulates the small fracture fragments through small percutaneous incisions and a robot that re-aligns the long bones. The robots controller design relies on accurate and bounded force and position parameters for which we require real surgical data. This paper reports preliminary findings of forces and torques applied during bone and soft tissue manipulation in typical orthopaedic surgery procedures. Using customised orthopaedic surgical tools we have collected data from a range of orthopaedic surgical procedures at Bristol Royal Infirmary, UK. Maximum forces and torques encountered during fracture manipulation which involved proximal femur and soft tissue distraction around it and reduction of neck of femur fractures have been recorded and further analysed in conjunction with accompanying image recordings. Using this data we are establishing a set of technical requirements for creating safe and dynamically stable minimally invasive robot-assisted fracture surgery (RAFS) systems.

  14. Cost analysis of open radical cystectomy versus robot-assisted radical cystectomy.

    Science.gov (United States)

    Bansal, Sukhchain S; Dogra, Tara; Smith, Peter W; Amran, Maisarah; Auluck, Ishna; Bhambra, Maninder; Sura, Manraj S; Rowe, Edward; Koupparis, Anthony

    2018-03-01

    To perform a cost analysis comparing the cost of robot-assisted radical cystectomy (RARC) with open RC (ORC) in a UK tertiary referral centre and to identify the key cost drivers. Data on hospital length of stay (LOS), operative time (OT), transfusion rate, and volume and complication rate were obtained from a prospectively updated institutional database for patients undergoing RARC or ORC. A cost decision tree model was created. Sensitivity analysis was performed to find key drivers of overall cost and to find breakeven points with ORC. Monte Carlo analysis was performed to quantify the variability in the dataset. One RARC procedure costs £12 449.87, or £12 106.12 if the robot was donated via charitable funds. In comparison, one ORC procedure costs £10 474.54. RARC is 18.9% more expensive than ORC. The key cost drivers were OT, LOS, and the number of cases performed per annum. High ongoing equipment costs remain a large barrier to the cost of RARC falling. However, minimal improvements in patient quality of life would be required to offset this difference. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  15. Safe teleoperation based on flexible intraoperative planning for robot-assisted laser microsurgery.

    Science.gov (United States)

    Mattos, Leonardo S; Caldwell, Darwin G

    2012-01-01

    This paper describes a new intraoperative planning system created to improve precision and safety in teleoperated laser microsurgeries. It addresses major safety issues related to real-time control of a surgical laser during teleoperated procedures, which are related to the reliability and robustness of the telecommunication channels. Here, a safe solution is presented, consisting in a new planning system architecture that maintains the flexibility and benefits of real-time teleoperation and keeps the surgeon in control of all surgical actions. The developed system is based on our virtual scalpel system for robot-assisted laser microsurgery, and allows the intuitive use of stylus to create surgical plans directly over live video of the surgical field. In this case, surgical plans are defined as graphic objects overlaid on the live video, which can be easily modified or replaced as needed, and which are transmitted to the main surgical system controller for subsequent safe execution. In the process of improving safety, this new planning system also resulted in improved laser aiming precision and improved capability for higher quality laser procedures, both due to the new surgical plan execution module, which allows very fast and precise laser aiming control. Experimental results presented herein show that, in addition to the safety improvements, the new planning system resulted in a 48% improvement in laser aiming precision when compared to the previous virtual scalpel system.

  16. A novel 3D-printed hybrid simulation model for robotic-assisted kidney transplantation (RAKT).

    Science.gov (United States)

    Uwechue, Raphael; Gogalniceanu, Petrut; Kessaris, Nicos; Byrne, Nick; Chandak, Pankaj; Olsburgh, Jonathon; Ahmed, Kamran; Mamode, Nizam; Loukopoulos, Ioannis

    2018-01-27

    Robotic-assisted kidney transplantation (RAKT) offers key benefits for patients that have been demonstrated in several studies. A barrier to the wider uptake of RAKT is surgical skill acquisition. This is exacerbated by the challenges of modern surgery with reduced surgical training time, patient safety concerns and financial pressures. Simulation is a well-established method of developing surgical skill in a safe and controlled environment away from the patient. We have developed a 3D printed simulation model for the key step of the kidney transplant operation which is the vascular anastomosis. The model is anatomically accurate, based on the CT scans of patients and it incorporates deceased donor vascular tissue. Crucially, it was developed to be used in the robotic operating theatre with the operating robot to enhance its fidelity. It is portable and relatively inexpensive when compared with other forms of simulation such as virtual reality or animal lab training. It thus has the potential of being more accessible as a training tool for the safe acquisition of RAKT specific skills. We demonstrate this model here.

  17. A new visual feedback-based magnetorheological haptic master for robot-assisted minimally invasive surgery

    Science.gov (United States)

    Choi, Seung-Hyun; Kim, Soomin; Kim, Pyunghwa; Park, Jinhyuk; Choi, Seung-Bok

    2015-06-01

    In this study, we developed a novel four-degrees-of-freedom haptic master using controllable magnetorheological (MR) fluid. We also integrated the haptic master with a vision device with image processing for robot-assisted minimally invasive surgery (RMIS). The proposed master can be used in RMIS as a haptic interface to provide the surgeon with a sense of touch by using both kinetic and kinesthetic information. The slave robot, which is manipulated with a proportional-integrative-derivative controller, uses a force sensor to obtain the desired forces from tissue contact, and these desired repulsive forces are then embodied through the MR haptic master. To verify the effectiveness of the haptic master, the desired force and actual force are compared in the time domain. In addition, a visual feedback system is implemented in the RMIS experiment to distinguish between the tumor and organ more clearly and provide better visibility to the operator. The hue-saturation-value color space is adopted for the image processing since it is often more intuitive than other color spaces. The image processing and haptic feedback are realized on surgery performance. In this work, tumor-cutting experiments are conducted under four different operating conditions: haptic feedback on, haptic feedback off, image processing on, and image processing off. The experimental realization shows that the performance index, which is a function of pixels, is different in the four operating conditions.

  18. A new visual feedback-based magnetorheological haptic master for robot-assisted minimally invasive surgery

    International Nuclear Information System (INIS)

    Choi, Seung-Hyun; Kim, Soomin; Kim, Pyunghwa; Park, Jinhyuk; Choi, Seung-Bok

    2015-01-01

    In this study, we developed a novel four-degrees-of-freedom haptic master using controllable magnetorheological (MR) fluid. We also integrated the haptic master with a vision device with image processing for robot-assisted minimally invasive surgery (RMIS). The proposed master can be used in RMIS as a haptic interface to provide the surgeon with a sense of touch by using both kinetic and kinesthetic information. The slave robot, which is manipulated with a proportional-integrative-derivative controller, uses a force sensor to obtain the desired forces from tissue contact, and these desired repulsive forces are then embodied through the MR haptic master. To verify the effectiveness of the haptic master, the desired force and actual force are compared in the time domain. In addition, a visual feedback system is implemented in the RMIS experiment to distinguish between the tumor and organ more clearly and provide better visibility to the operator. The hue-saturation-value color space is adopted for the image processing since it is often more intuitive than other color spaces. The image processing and haptic feedback are realized on surgery performance. In this work, tumor-cutting experiments are conducted under four different operating conditions: haptic feedback on, haptic feedback off, image processing on, and image processing off. The experimental realization shows that the performance index, which is a function of pixels, is different in the four operating conditions. (paper)

  19. Robot-assisted surgery: an emerging platform for human neuroscience research

    Directory of Open Access Journals (Sweden)

    Anthony Michael Jarc

    2015-06-01

    Full Text Available Classic studies in human sensorimotor control use simplified tasks to uncover fundamental control strategies employed by the nervous system. Such simple tasks are critical for isolating specific features of motor, sensory, or cognitive processes, and for inferring causality between these features and observed behavioral changes. However, it remains unclear how these theories translate to complex sensorimotor tasks or to natural behaviors. Part of the difficulty in performing such experiments has been the lack of appropriate tools for measuring complex motor skills in real-world contexts. Robot-assisted surgery (RAS provides an opportunity to overcome these challenges by enabling unobtrusive measurements of user behavior. In addition, a continuum of tasks with varying complexity – from simple tasks such as those in classic studies to highly complex tasks such as a surgical procedure – can be studied using RAS platforms. Finally, RAS includes a diverse participant population of inexperienced users all the way to expert surgeons. In this perspective, we illustrate how the characteristics of RAS systems make them compelling platforms to extend many theories in human neuroscience, as well as, to develop new theories altogether.

  20. Evaluating the effect of three-dimensional visualization on force application and performance time during robotics-assisted mitral valve repair.

    Science.gov (United States)

    Currie, Maria E; Trejos, Ana Luisa; Rayman, Reiza; Chu, Michael W A; Patel, Rajni; Peters, Terry; Kiaii, Bob B

    2013-01-01

    The purpose of this study was to determine the effect of three-dimensional (3D) binocular, stereoscopic, and two-dimensional (2D) monocular visualization on robotics-assisted mitral valve annuloplasty versus conventional techniques in an ex vivo animal model. In addition, we sought to determine whether these effects were consistent between novices and experts in robotics-assisted cardiac surgery. A cardiac surgery test-bed was constructed to measure forces applied during mitral valve annuloplasty. Sutures were passed through the porcine mitral valve annulus by the participants with different levels of experience in robotics-assisted surgery and tied in place using both robotics-assisted and conventional surgery techniques. The mean time for both the experts and the novices using 3D visualization was significantly less than that required using 2D vision (P robotic system with either 2D or 3D vision (P robotics-assisted mitral valve annuloplasty than during conventional open mitral valve annuloplasty. This finding suggests that 3D visualization does not fully compensate for the absence of haptic feedback in robotics-assisted cardiac surgery.

  1. Update on laparoscopic, robotic, and minimally invasive vaginal surgery for pelvic floor repair.

    Science.gov (United States)

    Ross, J W; Preston, M R

    2009-06-01

    Advanced laparoscopic surgery marked the beginning of minimally invasive pelvic surgery. This technique lead to the development of laparoscopic hysterectomy, colposuspension, paravaginal repair, uterosacral suspension, and sacrocolpopexy without an abdominal incision. With laparoscopy there is a significant decrease in postoperative pain, shorter length of hospital stay, and a faster return to normal activities. These advantages made laparoscopy very appealing to patients. Advanced laparoscopy requires a special set of surgical skills and in the early phase of development training was not readily available. Advanced laparoscopy was developed by practicing physicians, instead of coming down through the more usual academic channels. The need for special training did hinder widespread acceptance. Nonetheless by physician to physician training and society training courses it has continued to grow and now has been incorporated in most medical school curriculums. In the last few years there has been new interest in laparoscopy because of the development of robotic assistance. The 3D vision and 720 degree articulating arms with robotics have made suture intensive procedures much easier. Laparosco-pic robotic-assisted sacrocolpopexy is in the reach of most surgeons. This field is so new that there is very little data to evaluate at this time. There are short comings with laparoscopy and even with robotic-assisted procedures it is not the cure all for pelvic floor surgery. Laparoscopic procedures are long and many patients requiring pelvic floor surgery have medical conditions preventing long anesthesia. Minimally invasive vaginal surgery has developed from the concept of tissue replacement by synthetic mesh. Initially sheets of synthetic mesh were tailored by physicians to repair the anterior and posterior vaginal compartment. The use of mesh by general surgeons for hernia repair has served as a model for urogynecology. There have been rapid improvements in biomaterials

  2. Performance evaluation of a robot-assisted catheter operating system with haptic feedback.

    Science.gov (United States)

    Song, Yu; Guo, Shuxiang; Yin, Xuanchun; Zhang, Linshuai; Hirata, Hideyuki; Ishihara, Hidenori; Tamiya, Takashi

    2018-06-20

    In this paper, a novel robot-assisted catheter operating system (RCOS) has been proposed as a method to reduce physical stress and X-ray exposure time to physicians during endovascular procedures. The unique design of this system allows the physician to apply conventional bedside catheterization skills (advance, retreat and rotate) to an input catheter, which is placed at the master side to control another patient catheter placed at the slave side. For this purpose, a magnetorheological (MR) fluids-based master haptic interface has been developed to measure the axial and radial motions of an input catheter, as well as to provide the haptic feedback to the physician during the operation. In order to achieve a quick response of the haptic force in the master haptic interf