WorldWideScience

Sample records for rights reserved electrophoresis

  1. Surface Charge Measurement of SonoVue, Definity and Optison: A Comparison of Laser Doppler Electrophoresis and Micro-Electrophoresis.

    Science.gov (United States)

    Ja'afar, Fairuzeta; Leow, Chee Hau; Garbin, Valeria; Sennoga, Charles A; Tang, Meng-Xing; Seddon, John M

    2015-11-01

    Microbubble (MB) contrast-enhanced ultrasonography is a promising tool for targeted molecular imaging. It is important to determine the MB surface charge accurately as it affects the MB interactions with cell membranes. In this article, we report the surface charge measurement of SonoVue, Definity and Optison. We compare the performance of the widely used laser Doppler electrophoresis with an in-house micro-electrophoresis system. By optically tracking MB electrophoretic velocity in a microchannel, we determined the zeta potentials of MB samples. Using micro-electrophoresis, we obtained zeta potential values for SonoVue, Definity and Optison of -28.3, -4.2 and -9.5 mV, with relative standard deviations of 5%, 48% and 8%, respectively. In comparison, laser Doppler electrophoresis gave -8.7, +0.7 and +15.8 mV with relative standard deviations of 330%, 29,000% and 130%, respectively. We found that the reliability of laser Doppler electrophoresis is compromised by MB buoyancy. Micro-electrophoresis determined zeta potential values with a 10-fold improvement in relative standard deviation. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  2. Detection of telomerase activity using microchip electrophoresis.

    Science.gov (United States)

    Karasawa, Koji; Arakawa, Hidetoshi

    2015-07-01

    Telomerase participates in malignant transformation or immortalization of cells and thus has attracted attention as an anticancer drug target and diagnostic tumor marker. The telomeric repeat amplification protocol (TRAP) and improved TRAP methods (TRAP-fluorescence, TRAP-hybridization, etc.) are widely used forms of this telomerase assay. However, these approaches generally employ acrylamide gel electrophoresis after amplification of telomeric repeats by polymerase chain reaction (PCR), making these TRAP methods time consuming and technically demanding. In this study we developed a novel telomerase assay using microchip electrophoresis for rapid and highly sensitive detection of telomerase activity in cancer cells. The mixed gel of 0.8% hydroxypropyl methylcellulose (HPMC) and 0.3% polyethylene oxide (PEO) with SYBR Gold (fluorescent reagent) was used for microchip electrophoresis. As a result, the product amplified by a telomerase-positive cell could be measured in one cell per assay and detected with high reproducibility (CV=0.67%) in the short time of 100s. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Synthesis of hydrogel via click chemistry for DNA electrophoresis.

    Science.gov (United States)

    Finetti, Chiara; Sola, Laura; Elliott, Jim; Chiari, Marcella

    2017-09-01

    This work introduces a novel sieving gel for DNA electrophoresis using a classical click chemistry reaction, the copper (I)-catalyzed azide-alkyne cycloaddition (CuAAC), to cross-link functional polymer chains. The efficiency of this reaction provides, under mild conditions, hydrogels with near-ideal network connectivity and improved physical properties. Hydrogel formation via click chemistry condensation of functional polymers does not involve the use of toxic monomers and UV initiation. The performance of the new hydrogel in the separation of double stranded DNA fragments was evaluated in the 2200 TapeStation system, an analytical platform, recently introduced by Agilent that combines the advantages of CE in terms of miniaturization and automation with the simplicity of use of slab gel electrophoresis. The click gel enables addition of florescent dyes prior to electrophoresis with considerable improvement of resolution and separation efficiency over conventional cross-linked polyacrylamide gels. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. 25 CFR 226.12 - Government reserves right to purchase oil.

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Government reserves right to purchase oil. 226.12 Section... reserves right to purchase oil. Any of the executive departments of the U.S. Government shall have the... price as defined in § 226.11. ...

  5. 31 CFR 208.10 - Reservation of rights.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false Reservation of rights. 208.10 Section 208.10 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) FISCAL SERVICE, DEPARTMENT OF THE TREASURY FINANCIAL MANAGEMENT SERVICE MANAGEMENT OF FEDERAL AGENCY...

  6. 31 CFR 309.10 - Tenders; reservation of right to reject.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false Tenders; reservation of right to... BILLS § 309.10 Tenders; reservation of right to reject. In considering the acceptance of tenders, the highest prices offered will be accepted in full down to the amount required, and if the same price appears...

  7. 18 CFR 1314.4 - Law governing the rights and obligations of TVA and Reserve Banks; law governing the rights of...

    Science.gov (United States)

    2010-04-01

    ... rights and obligations of TVA and Reserve Banks; law governing the rights of any Person against TVA and... FEDERAL RESERVE BANKS § 1314.4 Law governing the rights and obligations of TVA and Reserve Banks; law governing the rights of any Person against TVA and Reserve Banks; law governing other interests. (a) Except...

  8. Direct detection of rutin-degrading isozymes with polyacrylamide gel electrophoresis.

    Science.gov (United States)

    Li, Yuping; Deng, Dandan; Zhang, Xuebin; Zhang, Haina; Wang, Cong; Chen, Peng

    2013-12-15

    Rutin-degrading enzymes (RDEs) specifically hydrolyze the glycosidic linkages of rutin, producing quercetin and rutinose. Here we report a reliable and sensitive polyacrylamide gel electrophoresis and staining method for the detection of RDE isozymes, which is based on the aqueous solubility difference between rutin and quercetin, as well as the ultraviolet absorbance of quercetin. With this novel method, we achieved a detection limit of 12 ng with 107 U of RDE activity, enabling us to detect at least five RDE isozymes in tartary buckwheat seeds. Copyright © 2013 Elsevier Inc. All rights reserved.

  9. A method for easily customizable gradient gel electrophoresis.

    Science.gov (United States)

    Miller, Andrew J; Roman, Brandon; Norstrom, Eric

    2016-09-15

    Gradient polyacrylamide gel electrophoresis is a powerful tool for the resolution of polypeptides by relative mobility. Here, we present a simplified method for generating polyacrylamide gradient gels for routine analysis without the need for specialized mixing equipment. The method allows for easily customizable gradients which can be optimized for specific polypeptide resolution requirements. Moreover, the method eliminates the possibility of buffer cross contamination in mixing equipment, and the time and resources saved with this method in place of traditional gradient mixing, or the purchase of pre-cast gels, are noteworthy given the frequency with which many labs use gradient gel SDS-PAGE. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Factors affecting the separation performance of proteins in capillary electrophoresis.

    Science.gov (United States)

    Zhu, Yueping; Li, Zhenqing; Wang, Ping; Shen, Lisong; Zhang, Dawei; Yamaguchi, Yoshinori

    2018-04-15

    Capillary electrophoresis (CE) is an effective tool for protein separation and analysis. Compared with capillary gel electrophoresis (CGE), non-gel sieving capillary electrophoresis (NGSCE) processes the superiority on operation, repeatability and automaticity. Herein, we investigated the effect of polymer molecular weight and concentration, electric field strength, and the effective length of the capillary on the separation performance of proteins, and find that (1) polymer with high molecular weight and concentration favors the separation of proteins, although concentrated polymer hinders its injection into the channel of the capillary due to its high viscosity. (2) The resolution between the adjacent proteins decreases with the increase of electric field strength. (3) When the effective length of the capillary is long, the separation performance improves at the cost of separation time. (4) 1.4% (w/v) hydroxyethyl cellulose (HEC), 100 V/cm voltage and 12 cm effective length offers the best separation for the proteins with molecular weight from 14,400 Da to 97,400 Da. Finally, we employed the optimal electrophoretic conditions to resolve Lysozyme, Ovalbumin, BSA and their mixtures, and found that they were baseline resolved within 15 min. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. 25 CFR 213.17 - Government reserves right to purchase minerals produced.

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Government reserves right to purchase minerals produced... Leases § 213.17 Government reserves right to purchase minerals produced. In time of war or other public... prevailing market price on the date of sale all or any part of the minerals produced under any lease. Rents...

  12. Review: Authentication and traceability of foods from animal origin by polymerase chain reaction-based capillary electrophoresis.

    Science.gov (United States)

    Rodríguez-Ramírez, Roberto; González-Córdova, Aarón F; Vallejo-Cordoba, Belinda

    2011-01-31

    This work presents an overview of the applicability of PCR-based capillary electrophoresis (CE) in food authentication and traceability of foods from animal origin. Analytical approaches for authenticating and tracing meat and meat products and fish and seafood products are discussed. Particular emphasis will be given to the usefulness of genotyping in food tracing by using CE-based genetic analyzers. Copyright © 2010 Elsevier B.V. All rights reserved.

  13. Disc electrophoresis and related techniques of polyacrylamide gel electrophoresis

    National Research Council Canada - National Science Library

    Maurer, H. R

    1971-01-01

    ..., enzymes, antingens and radioactively labelled materials, and detailed treatments of micro disc electrophoresis, preparative polyacrylamide gel electrophoresis and many other techniques for special problems...

  14. Electrophoresis forum '80

    International Nuclear Information System (INIS)

    Radola, B.J.

    1980-01-01

    In this volume the contributions of the electrophoresis meeting are presented in a short term form. The main topics are gel-electrophoresis, ultra thin film isoelectric focusing, one- and two-dimensional electrophoresis, electrophoretical separation techniques, electric focusing (for phorensic studies), substrate free and substrate electrophoresis. In the poster session of this meeting subjects such as (ultra) thin film isoelectric focusing, identification of radioactive proteins, labelling of cell surfaces, autoradiography and 3 H-labelled proteins. Separate abstracts were prepared for 4 papers in this report. (HK) [de

  15. 25 CFR 227.14 - Government reserves right to purchase oil and gas.

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Government reserves right to purchase oil and gas. 227.14... § 227.14 Government reserves right to purchase oil and gas. In time of war or other public emergency any... posted market price on the date of sale all or any part of the minerals produced under any lease. Rents...

  16. Comparison of non-electrophoresis grade with electrophoresis grade BIS in NIPAM polymer gel preparation

    Science.gov (United States)

    Khodadadi, Roghayeh; Khajeali, Azim; Farajollahi, Ali Reza; Hajalioghli, Parisa; Raeisi, Noorallah

    2015-01-01

    Introduction:The main objective of this study was to investigate the possibility of replacing electrophoresis cross-linker with non-electrophoresis N, N′-methylenebisacrylamide (BIS) in N-isopropyl acrylamide (NIPAM) polymer gel and its possible effect on dose response. Methods: NIPAM polymer gel was prepared from non-electrophoresis grade BIS and the relaxation rate (R2) was measured by MR imaging after exposing the gel to gamma radiation from Co-60 source. To compare the response of this gel with the one that contains electrophoresis grade BIS, two sets of NIPAM gel were prepared using electrophoresis and non-electrophoresis BIS and irradiated to different gamma doses. Results: It was found that the dose–response of NIPAM gel made from the non-electrophoresis grade BIS is coincident with that of electrophoresis grade BIS. Conclusion:Taken all, it can be concluded that the non-electrophoresis grade BIS not only is a suitable alternative for the electrophoresis grade BIS but also reduces the cost of gel due to its lower price. PMID:26457250

  17. Development in electrophoresis: instrumentation for two-dimensional gel electrophoresis of protein separation and application of capillary electrophoresis in micro-bioanalysis

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Aoshuang [Iowa State Univ., Ames, IA (United States)

    2008-01-01

    This dissertation begins with a general introduction of topics related to this work. The following chapters contain three scientific manuscripts, each presented in a separate chapter with accompanying tables, figures, and literature citations. The final chapter summarizes the work and provides some prospective on this work. This introduction starts with a brief treatment of the basic principles of electrophoresis separation, followed by a discussion of gel electrophoresis and particularly polyacrylamide gel electrophoresis for protein separation, a summary of common capillary electrophoresis separation modes, and a brief treatment of micro-bioanalysis application of capillary electrophoresis, and ends with an overview of protein conformation and dynamics.

  18. Affinity in electrophoresis.

    Science.gov (United States)

    Heegaard, Niels H H

    2009-06-01

    The journal Electrophoresis has greatly influenced my approaches to biomolecular affinity studies. The methods that I have chosen as my main tools to study interacting biomolecules--native gel and later capillary zone electrophoresis--have been the topic of numerous articles in Electrophoresis. Below, the role of the journal in the development and dissemination of these techniques and applications reviewed. Many exhaustive reviews on affinity electrophoresis and affinity CE have been published in the last few years and are not in any way replaced by the present deliberations that are focused on papers published by the journal.

  19. Determination of acid dissociation constants of warfarin and hydroxywarfarins by capillary electrophoresis.

    Science.gov (United States)

    Nowak, Paweł; Olechowska, Paulina; Mitoraj, Mariusz; Woźniakiewicz, Michał; Kościelniak, Paweł

    2015-08-10

    In this work the acid dissociation constants--pKa of warfarin and its all important oxidative metabolites have been determined by capillary electrophoresis-based methods. It has resulted in a complete description of two acid-base dissociation equilibria, yet not investigated experimentally for phase I metabolites of warfarin. The capillary electrophoresis (CE) method based on the relation between effective electrophoretic mobilities and pH has proven to be a suitable tool for pKa determination, while the spectrophotometric (CE-DAD) and the internal standard methods (IS-CE), have appeared to be promising alternative approaches. The CE-DAD approach based on the change in absorbance spectra between the acidic and basic forms is a combination between capillary electrophoresis and spectrophotometric titration, and yields very consistent values of pKa1 with CE. The IS-CE, in turn, enables an estimation of pKa1 and pKa2 from only two analytical runs, however, less accurate than CE and CE-DAD. The Debye-Hückel model has been confirmed experimentally as a good predictor of pKa values at various ionic strengths. Therefore, it has been used in determination of thermodynamic pKa1 and pKa2, referring to the zero ionic strength. The results are important from the analytical, pharmacological, and theoretical points of view. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Evaluation of capillary zone electrophoresis for the determination of protein composition in therapeutic immunoglobulins and human albumins.

    Science.gov (United States)

    Christians, Stefan; van Treel, Nadine Denise; Bieniara, Gabriele; Eulig-Wien, Annika; Hanschmann, Kay-Martin; Giess, Siegfried

    2016-07-01

    Capillary zone electrophoresis (CZE) provides an alternative means of separating native proteins on the basis of their inherent electrophoretic mobilities. The major advantage of CZE is the quantification by UV detection, circumventing the drawbacks of staining and densitometry in the case of gel electrophoresis methods. The data of this validation study showed that CZE is a reliable assay for the determination of protein composition in therapeutic preparations of human albumin and human polyclonal immunoglobulins. Data obtained by CZE are in line with "historical" data obtained by the compendial method, provided that peak integration is performed without time correction. The focus here was to establish a rapid and reliable test to substitute the current gel based zone electrophoresis techniques for the control of protein composition of human immunoglobulins or albumins in the European Pharmacopoeia. We believe that the more advanced and modern CZE method described here is a very good alternative to the procedures currently described in the relevant monographs. Copyright © 2016 International Alliance for Biological Standardization. Published by Elsevier Ltd. All rights reserved.

  1. Inhibition study of alanine aminotransferase enzyme using sequential online capillary electrophoresis analysis.

    Science.gov (United States)

    Liu, Lina; Chen, Yuanfang; Yang, Li

    2014-12-15

    We report the study of several inhibitors on alanine aminotransferase (ALT) enzyme using sequential online capillary electrophoresis (CE) assay. Using metal ions (Na(+) and Mg(2+)) as example inhibitors, we show that evolution of the ALT inhibition reaction can be achieved by automatically and simultaneously monitoring the substrate consumption and product formation as a function of reaction time. The inhibition mechanism and kinetic constants of ALT inhibition with succinic acid and two traditional Chinese medicines were derived from the sequential online CE assay. Our study could provide valuable information about the inhibition reactions of ALT enzyme. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Thalassemia and hemoglobinopathies in Southeast Asian newborns: diagnostic assessment using capillary electrophoresis system.

    Science.gov (United States)

    Srivorakun, Hataichanok; Fucharoen, Goonnapa; Changtrakul, Yossombat; Komwilaisak, Patcharee; Fucharoen, Supan

    2011-04-01

    We have investigated the Capillarys 2 Hemoglobin testing system to assist in presumptive diagnosis of thalassemia and hemoglobinopathies commonly found in Southeast Asia. Study was conducted on 226 newborns. Hematological parameters were recorded and Hb profiles were examined on the Capillarys 2 Hemoglobin analyzer (SEBIA). DNA analyses were used to establish the final diagnoses. Among 226 newborns examined, 122 had thalassemias with 17 different genotypes. The capillary electrophoresis system could provide useful data for presumptive diagnoses of cases, especially those with Hb E and α-thalassemia. Hb E was found to be 2.6-6.2% in heterozygote whereas Hb Bart's were clearly observed in cases with compound heterozygous or homozygous α(+)-thalassemia and heterozygous α(0)-thalassemia. Hb H disease and other forms of α-thalassemia could be differentiated based on the presence of Hb Bart's and its percentage. The capillary electrophoresis system is applicable to newborn screening for common forms of thalassemia in Southeast Asia. Copyright © 2011 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  3. Continuous protein concentration via free-flow moving reaction boundary electrophoresis.

    Science.gov (United States)

    Kong, Fanzhi; Zhang, Min; Chen, Jingjing; Fan, Liuyin; Xiao, Hua; Liu, Shaorong; Cao, Chengxi

    2017-07-28

    In this work, we developed the model and theory of free-flow moving reaction boundary electrophoresis (FFMRB) for continuous protein concentration for the first time. The theoretical results indicated that (i) the moving reaction boundary (MRB) can be quantitatively designed in free-flow electrophoresis (FFE) system; (ii) charge-to-mass ratio (Z/M) analysis could provide guidance for protein concentration optimization; and (iii) the maximum processing capacity could be predicted. To demonstrate the model and theory, three model proteins of hemoglobin (Hb), cytochrome C (Cyt C) and C-phycocyanin (C-PC) were chosen for the experiments. The experimental results verified that (i) stable MRBs with different velocities could be established in FFE apparatus with weak acid/weak base neutralization reaction system; (ii) proteins of Hb, Cyt C and C-PC were well concentrated with FFMRB; and (iii) a maximum processing capacity and recovery ratio of Cyt C enrichment were 126mL/h and 95.5% respectively, and a maximum enrichment factor was achieved 12.6 times for Hb. All of the experiments demonstrated the protein concentration model and theory. In contrast to other methods, the continuous processing ability enables FFMRB to efficiently enrich diluted protein or peptide in large volume solution. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. In situ synthesis of bilayered gradient poly(vinyl alcohol)/hydroxyapatite composite hydrogel by directional freezing-thawing and electrophoresis method.

    Science.gov (United States)

    Su, Cui; Su, Yunlan; Li, Zhiyong; Haq, Muhammad Abdul; Zhou, Yong; Wang, Dujin

    2017-08-01

    Bilayered poly(vinyl alcohol) (PVA)/hydroxyapatite (HA) composite hydrogels with anisotropic and gradient mechanical properties were prepared by the combination of directional freezing-thawing (DFT) and electrophoresis method. Firstly, PVA hydrogels with aligned channel structure were prepared by the DFT method. Then, HA nanoparticles were in situ synthesized within the PVA hydrogels via electrophoresis. By controlling the time of the electrophoresis process, a bilayered gradient hydrogel containing HA particles in only half of the gel region was obtained. The PVA/HA composite hydrogel exhibited gradient mechanical strength depending on the distance to the cathode. The gradient initial tensile modulus ranging from 0.18MPa to 0.27MPa and the gradient initial compressive modulus from 0.33MPa to 0.51MPa were achieved. The binding strength of the two regions was relatively high and no apparent internal stress or defect was observed at the boundary. The two regions of the bilayered hydrogel also showed different osteoblast cell adhesion properties. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. On the use of capillary electrophoresis for the determination of inorganic anions and cations, and carbohydrates in residues collected after a simulated suicide bombing attack.

    Science.gov (United States)

    Sarazin, Cédric; Delaunay, Nathalie; Costanza, Christine; Eudes, Véronique; Gareil, Pierre

    2013-01-15

    In order to train scientist field investigators after terrorist attacks, the laboratory of the Prefecture de Police of Paris simulated a suicide bombing attack in a bus. After collection of the residues, analyses were carried out to determine the composition of the original explosive charge. This article focuses on the combined use, for the first time, of three new capillary electrophoresis methods for the determination of inorganic anions and cations, and carbohydrates in two representative extracts. Capillary electrophoresis appears as an effective tool to identify and quantify the compounds in real extracts and is fully complementary to chromatographic methods. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. Modification of gel architecture and TBE/TAE buffer composition to minimize heating during agarose gel electrophoresis.

    Science.gov (United States)

    Sanderson, Brian A; Araki, Naoko; Lilley, Jennifer L; Guerrero, Gilberto; Lewis, L Kevin

    2014-06-01

    Agarose gel electrophoresis of DNA and RNA is routinely performed using buffers containing either Tris, acetate, and EDTA (TAE) or Tris, borate, and EDTA (TBE). Gels are run at a low, constant voltage (∼10 V/cm) to minimize current and asymmetric heating effects, which can induce band artifacts and poor resolution. In this study, alterations of gel structure and conductive media composition were analyzed to identify factors causing higher electrical currents during horizontal slab gel electrophoresis. Current was reduced when thinner gels and smaller chamber buffer volumes were used, but was not influenced by agarose concentration or the presence of ethidium bromide. Current was strongly dependent on the amount and type of EDTA used and on the concentrations of the major acid-base components of each buffer. Interestingly, resolution and the mobilities of circular versus linear plasmid DNAs were also affected by the chemical form and amount of EDTA. With appropriate modifications to gel structure and buffer constituents, electrophoresis could be performed at high voltages (20-25 V/cm), reducing run times by up to 3-fold. The most striking improvements were observed with small DNAs and RNAs (10-100 bp): high voltages and short run times produced sharper bands and higher resolution. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Lectin affinity electrophoresis.

    Science.gov (United States)

    Kobayashi, Yuka

    2014-01-01

    An interaction or a binding event typically changes the electrophoretic properties of a molecule. Affinity electrophoresis methods detect changes in the electrophoretic pattern of molecules (mainly macromolecules) that occur as a result of biospecific interactions or complex formation. Lectin affinity electrophoresis is a very effective method for the detection and analysis of trace amounts of glycobiological substances. It is particularly useful for isolating and separating the glycoisomers of target molecules. Here, we describe a sensitive technique for the detection of glycoproteins separated by agarose gel-lectin affinity electrophoresis that uses antibody-affinity blotting. The technique is tested using α-fetoprotein with lectin (Lens culinaris agglutinin and Phaseolus vulgaris agglutinin)-agarose gels.

  8. Electrophoresis technology

    Science.gov (United States)

    Snyder, R. S.

    1985-01-01

    A new high resolution apparatus designed for space was built as a laboratory prototype. Using a moving wall with a low zeta potential coating, the major sources of flow distortion for an electrophoretic sample stream are removed. Highly resolved fractions, however, will only be produced in space because of the sensitivity of this chamber to buoyancy-induced convection in the laboratory. The second and third flights of the McDonnell Douglas Astronautics Corporation continuous flow electrophoresis system carried samples developed at MSFC intended to evaluate the broad capabilities of free flow electrophoresis in a reduced gravity environment. Biological model materials, hemoglobin and polystyrene latex microspheres, were selected because of their past use as electrophoresis standards and as visible markers for fluid flow due to electroosmosis, spacecraft acceleration or other factors. The dependence of the separation resolution on the properties of the sample and its suspension solution was assessed.

  9. 31 CFR 354.2 - Law governing rights and obligations of Federal Reserve Banks, and Sallie Mae; rights of any...

    Science.gov (United States)

    2010-07-01

    ... on the books of a Federal Reserve Bank pursuant to § 354.4(c)(1), is governed by the law (not... recorded on the books of a Federal Reserve Bank pursuant to § 354.14(c)(1), is governed by the law... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false Law governing rights and obligations...

  10. Coronary reserve of the right ventricle evaluated by double dose Tl-201 scintigraphy

    International Nuclear Information System (INIS)

    Sugihara, Hiroki; Adachi, Haruhiko; Nakagawa, Hiroaki

    1985-01-01

    Thallium-201 double dose scintigraphy was applied to exercise to estimate the coronary blood flow reserve of the left and right ventricles and this was compared with the degree of coronary artery stenosis. As an index of coronary reserve we measured the rate of change of blood flow distribution (ΔF) calculated from the change in myocardial radioactivity following thallium-201 injections, once at rest and once during exercise. With submaximal exercise the increases in ΔF of the left ventricle were less in patients with ischemic heart disease than in the control subjects, and were less as the number of diseased coronary vessels increased. The increases of ΔF of the right ventricle were less in patients with stenosis of the proximal portion of the right coronary artery than in patients without stenosis and in the control subjects. The more severe the stenosis of the proximal portion of the right coronary artery, the smaller the ΔF of the right ventricle. These results indicate that evaluation of the ΔF in the left and right ventricles is useful in estimating coronary artery stenosis. (author)

  11. Van de Graaff generator for capillary electrophoresis.

    Science.gov (United States)

    Lee, Seung Jae; Castro, Eric R; Guijt, Rosanne M; Tarn, Mark D; Manz, Andreas

    2017-09-29

    A new approach for high voltage capillary electrophoresis (CE) is proposed, which replaces the standard high voltage power supply with a Van de Graaff generator, a low current power source. Because the Van de Graaff generator is a current-limited source (10μA), potentials exceeding 100kV can be generated for CE when the electrical resistance of the capillary is maximized. This was achieved by decreasing the capillary diameter and reducing the buffer ionic strength. Using 2mM borate buffer and a 5μm i.d. capillary, fluorescently labeled amino acids were separated with efficiencies up to 3.5 million plates; a 5.7 fold improvement in separation efficiency compared to a normal power supply (NPS) typically used in CE. This separation efficiency was realized using a simple set-up without significant Joule heating, making the Van de Graaff generator a promising alternative for applying the high potentials required for enhancing resolution in the separation and analysis of highly complex samples, for example mixtures of glycans. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Cu2+-assisted two dimensional charge-mass double focusing gel electrophoresis and mass spectrometric analysis of histone variants.

    Science.gov (United States)

    Zhang, Wenyang; Tang, Xuemei; Ding, Mengjie; Zhong, Hongying

    2014-12-10

    Abundant isoforms and dynamic posttranslational modifications cause the separation and identification of histone variants to be experimentally challenging. To meet this need, we employ two-dimensional electrophoretic gel separation followed by mass spectrometric detection which takes advantage of the chelation of Cu(2+) with amino acid residues exposed on the surfaces of the histone proteins. Acid-extracted rat liver histones were first mixed with CuSO4 solution and then separated in one dimension with triton-acid-urea (TAU) gel electrophoresis and in a second dimension using sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE). The separations result from both the changes in charge and mass upon Cu(2+) chelation. Identities of each separated gel bands were obtained by using matrix-assisted laser desorption-ionization mass spectrometry (MALDI-MS). It was found that the migration of H3 histone isoforms of rat liver is markedly affected by the use of Cu(2+) ions. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Microchip analysis of lithium in blood using moving boundary electrophoresis and zone electrophoresis

    NARCIS (Netherlands)

    Vrouwe, E.X.; Lüttge, Regina; Olthuis, Wouter; van den Berg, Albert

    The determination of inorganic cations in blood plasma is demonstrated using a combination of moving boundary electrophoresis (MBE) and zone electrophoresis. The sample loading performed under MBE conditions is studied with the focus on the quantitative analysis of lithium. A concentration

  14. Microchip analysis of lithium in blood using moving boundary electrophoresis and zone electrophoresis

    NARCIS (Netherlands)

    Vrouwe, E.X.; Luttge, R.; Olthuis, W.; Berg, van den A.

    2005-01-01

    The determination of inorganic cations in blood plasma is demonstrated using a combination of moving boundary electrophoresis (MBE) and zone electrophoresis. The sample loading performed under MBE conditions is studied with the focus on the quantitative analysis of lithium. A concentration

  15. A global survey of “TURF-reserves”, Territorial Use Rights for Fisheries coupled with marine reserves

    Directory of Open Access Journals (Sweden)

    Jamie C. Afflerbach

    2014-12-01

    Full Text Available Overfishing and degradation of the marine environment continue to plague coastal communities worldwide, with multiple diverse solutions being proposed. Territorial Use Rights for Fisheries (TURFs is a fishery management approach that aligns fishers’ incentives with sustainability, while marine reserves have proven effective for ecosystem protection, and in some cases for fishery enhancement. These two management approaches are often used in isolation, leaving the potential utility of integrating them poorly understood. We examine cases where TURFs and marine reserves have been implemented together to create “TURF-reserves”. We compiled a database of 27 TURF-reserves and collected information on the governance, management, enforcement, fishing practices, fishing rights, regulations, and design attributes for each site. We address several research questions including: what species are managed with TURF-reserves, how are TURF-reserves created and who is involved in the process? Our findings show that the majority of surveyed TURF-reserves arose from previously established TURF systems that target a range of fisheries, and multiple entities play a role in TURF-reserve development and management. We also examine the differences between two TURF-reserve archetypes and find that those developed with a strong history of customary tenure share distinct qualities from those created in a more recently established, government-mandated system. Keywords: TURF, Marine reserve, TURF-reserve, Fisheries, Rights-based management

  16. DNA typing by capillary electrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, N.

    1997-10-08

    Capillary electrophoresis is becoming more and more important in nucleic acid analysis including DNA sequencing, typing and disease gene measurements. This work summarized the background of DNA typing. The recent development of capillary electrophoresis was also discussed. The second part of the thesis showed the principle of DNA typing based on using the allelic ladder as the absolute standard ladder in capillary electrophoresis system. Future work will be focused on demonstrating DNA typing on multiplex loci and examples of disease diagnosis in the on-line format of PCR-CE. Also capillary array electrophoresis system should allow high throughput, fast speed DNA typing. Only the introduction and conclusions for this report are available here. A reprint was removed for separate processing.

  17. Biomedical applications of capillary electrophoresis

    International Nuclear Information System (INIS)

    Kartsova, L A; Bessonova, E A

    2015-01-01

    The review deals with modern analytical approaches used in capillary electrophoresis for solving medical and biological problems: search for biomarkers of various diseases and rapid diagnosis based on characteristic profiles of biologically active compounds by capillary electrophoresis with mass spectrometric detection; monitoring of the residual drugs in biological fluids for evaluating the efficiency of drug therapy; testing of the enantiomeric purity of pharmaceutical products; the use of novel materials as components of stationary and pseudo-stationary phases in capillary electrophoresis and capillary electrochromatography to increase the selectivity of separation of components of complex matrices; and identification of various on-line preconcentration techniques to reduce the detection limits of biologically active analytes. A topical trend in capillary electrophoresis required in clinical practice, viz., the design of microfluidic systems, is discussed. The bibliography includes 173 references

  18. Supramolecular gel electrophoresis of large DNA fragments.

    Science.gov (United States)

    Tazawa, Shohei; Kobayashi, Kazuhiro; Oyoshi, Takanori; Yamanaka, Masamichi

    2017-10-01

    Pulsed-field gel electrophoresis is a frequent technique used to separate exceptionally large DNA fragments. In a typical continuous field electrophoresis, it is challenging to separate DNA fragments larger than 20 kbp because they migrate at a comparable rate. To overcome this challenge, it is necessary to develop a novel matrix for the electrophoresis. Here, we describe the electrophoresis of large DNA fragments up to 166 kbp using a supramolecular gel matrix and a typical continuous field electrophoresis system. C 3 -symmetric tris-urea self-assembled into a supramolecular hydrogel in tris-boric acid-EDTA buffer, a typical buffer for DNA electrophoresis, and the supramolecular hydrogel was used as a matrix for electrophoresis to separate large DNA fragments. Three types of DNA marker, the λ-Hind III digest (2 to 23 kbp), Lambda DNA-Mono Cut Mix (10 to 49 kbp), and Marker 7 GT (10 to 165 kbp), were analyzed in this study. Large DNA fragments of greater than 100 kbp showed distinct mobility using a typical continuous field electrophoresis system. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. The Cutting Edge of Affinity Electrophoresis Technology.

    Science.gov (United States)

    Kinoshita, Eiji; Kinoshita-Kikuta, Emiko; Koike, Tohru

    2015-03-18

    Affinity electrophoresis is an important technique that is widely used to separate and analyze biomolecules in the fields of biology and medicine. Both quantitative and qualitative information can be gained through affinity electrophoresis. Affinity electrophoresis can be applied through a variety of strategies, such as mobility shift electrophoresis, charge shift electrophoresis or capillary affinity electrophoresis. These strategies are based on changes in the electrophoretic patterns of biological macromolecules that result from interactions or complex-formation processes that induce changes in the size or total charge of the molecules. Nucleic acid fragments can be characterized through their affinity to other molecules, for example transcriptional factor proteins. Hydrophobic membrane proteins can be identified by means of a shift in the mobility induced by a charged detergent. The various strategies have also been used in the estimation of association/disassociation constants. Some of these strategies have similarities to affinity chromatography, in that they use a probe or ligand immobilized on a supported matrix for electrophoresis. Such methods have recently contributed to profiling of major posttranslational modifications of proteins, such as glycosylation or phosphorylation. Here, we describe advances in analytical techniques involving affinity electrophoresis that have appeared during the last five years.

  20. Agarose-gel electrophoresis for the quality assurance and purity of heparin formulations.

    Science.gov (United States)

    Volpi, Nicola; Buzzega, Dania

    2012-01-01

    The adulteration of raw heparin (Hep) with a synthetic oversulfated chondroitin sulfate (OSCS) not found in nature produced in 2007-2008 a global crisis giving rise to the development of additional, new and specific methods for its quality assurance and purity. In this study, a simple and sensitive agarose-gel electrophoresis method has been developed for the visualization of OSCS in Hep samples along with other natural glycosaminoglycans possibly present as "process-related impurities", in particular dermatan sulfate (DS) and chondroitin sulfate (CS). Agarose-gel electrophoresis under non-conventional conditions is able to separate OSCS from Hep with its two components, the slow-moving and fast-moving species, DS and CS by performing separation for 15 h (overnight) and under high voltage (100 mA, ∼200 V). Densitometric scanning enabled us to calculate a limit of detection of ∼0.5 μg OSCS with a linear behaviour from 0.1 to 5 μg, comparable to CS/DS. Contaminated samples from Hep manufacturers were analyzed and quantitative data were found comparable to previous studies. Due to its capacity to process many samples in a single run and to the equipment commonly available in laboratories, this analytical method would be suitable for the identification and quantification of contamination by other polysaccharides, in particular OSCS and DS, within Hep preparations and formulations. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Research on pre-staining gel electrophoresis

    International Nuclear Information System (INIS)

    Zhong Ruibo; Liu Yushuang; Zhang Ping; Liu Jingran; Zhao Guofen; Zhang Feng

    2014-01-01

    Background: Gel electrophoresis is a powerful biochemical separation technique. Most biological molecules are completely transparent in the visible region of light, so it is necessary to use staining to show the results after gel electrophoresis, and the general steps of conventional staining methods are time-consuming. Purpose: We try to develop a novel approach to simplify the gel electrophoresis: Pre-Staining Gel Electrophoresis (PSGE), which can make the gel electrophoresis results monitored in real time. Methods: Pre-stain the protein samples with Coomassie Brilliant Blue (CBB) for 30 min before loading the sample into the gel well. Results and Conclusion: PSGE can be successfully used to analyze the binding efficiency of Bovine Serum Albumin (BSA) and amphiphilic polymer via chemical coupling and physical absorption, and the double PSGE also shows a great potential in bio-analytical chemistry. (authors)

  2. The Cutting Edge of Affinity Electrophoresis Technology

    Science.gov (United States)

    Kinoshita, Eiji; Kinoshita-Kikuta, Emiko; Koike, Tohru

    2015-01-01

    Affinity electrophoresis is an important technique that is widely used to separate and analyze biomolecules in the fields of biology and medicine. Both quantitative and qualitative information can be gained through affinity electrophoresis. Affinity electrophoresis can be applied through a variety of strategies, such as mobility shift electrophoresis, charge shift electrophoresis or capillary affinity electrophoresis. These strategies are based on changes in the electrophoretic patterns of biological macromolecules that result from interactions or complex-formation processes that induce changes in the size or total charge of the molecules. Nucleic acid fragments can be characterized through their affinity to other molecules, for example transcriptional factor proteins. Hydrophobic membrane proteins can be identified by means of a shift in the mobility induced by a charged detergent. The various strategies have also been used in the estimation of association/disassociation constants. Some of these strategies have similarities to affinity chromatography, in that they use a probe or ligand immobilized on a supported matrix for electrophoresis. Such methods have recently contributed to profiling of major posttranslational modifications of proteins, such as glycosylation or phosphorylation. Here, we describe advances in analytical techniques involving affinity electrophoresis that have appeared during the last five years. PMID:28248262

  3. Conducting polymer electrodes for gel electrophoresis.

    Directory of Open Access Journals (Sweden)

    Katarina Bengtsson

    Full Text Available In nearly all cases, electrophoresis in gels is driven via the electrolysis of water at the electrodes, where the process consumes water and produces electrochemical by-products. We have previously demonstrated that π-conjugated polymers such as poly(3,4-ethylenedioxythiophene (PEDOT can be placed between traditional metal electrodes and an electrolyte to mitigate electrolysis in liquid (capillary electroosmosis/electrophoresis systems. In this report, we extend our previous result to gel electrophoresis, and show that electrodes containing PEDOT can be used with a commercial polyacrylamide gel electrophoresis system with minimal impact to the resulting gel image or the ionic transport measured during a separation.

  4. Conducting polymer electrodes for gel electrophoresis.

    Science.gov (United States)

    Bengtsson, Katarina; Nilsson, Sara; Robinson, Nathaniel D

    2014-01-01

    In nearly all cases, electrophoresis in gels is driven via the electrolysis of water at the electrodes, where the process consumes water and produces electrochemical by-products. We have previously demonstrated that π-conjugated polymers such as poly(3,4-ethylenedioxythiophene) (PEDOT) can be placed between traditional metal electrodes and an electrolyte to mitigate electrolysis in liquid (capillary electroosmosis/electrophoresis) systems. In this report, we extend our previous result to gel electrophoresis, and show that electrodes containing PEDOT can be used with a commercial polyacrylamide gel electrophoresis system with minimal impact to the resulting gel image or the ionic transport measured during a separation.

  5. Identification of snake venom allergens by two-dimensional electrophoresis followed by immunoblotting.

    Science.gov (United States)

    Hu, Yujing; Yang, Liming; Yang, Haiwei; He, Shaoheng; Wei, Ji-Fu

    2017-01-01

    This allergic reaction to snake venom was described to occur in patients after recurrent exposure through bites in amateur and professional snake handlers, which might be underestimated and contribute to fatal snakebites in victim, independently from the toxicity of the venom itself. Few allergens were identified from snake venoms by normal SDS-PAGE, which cannot separate the snake venom completely. In the present study, we identified nine potential allergens by two-dimensional (2D) electrophoresis followed by immunoblotting (named as allergenomics) in Protobothrops mucrosquamatus venom. By multidimensional liquid chromatography-ion trap mass spectrometry (MDLC-ESI-LTQ-MS/MS) analysis, six allergens showed sequence similarity to snake venom serine proteinases. Other allergens showed sequence similarity to snake venom metalloproteinase. These allergic reactions to snake venom allergens might contribute to fatal snakebites in victim, independently. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Integration of capillary electrophoresis with gold nanoparticle-based colorimetry.

    Science.gov (United States)

    Li, Tong; Wu, Zhenglong; Qin, Weidong

    2017-12-01

    A method integrating capillary electrophoresis (CE) and gold nanoparticle aggregation-based colorimetry (AuNP-ABC) was described. By using a dual-sheath interface, the running buffer was isolated from the colorimetric reaction solution so that CE and AuNP-ABC would not interfere with each other. The proof-of-concept was validated by assay of polyamidoamine (PAMAM) dendrimers that were fortified in human urine samples. The factors influencing the CE-AuNP-ABC performances were investigated and optimized. Under the optimal conditions, the dendrimers were separated within 8 min, with detection limits of 0.5, 1.2 and 2.6 μg mL -1 for PAMAM G1.0, G2.0 and G3.0, respectively. The sensitivity of CE-AuNP-ABC was comparable to or even better than those of liquid chromatography-fluorimetry and liquid chromatography-mass spectrometry. The results suggested that the proposed strategy can be applied to facile and quick determination of analytes of similar properties in complex matrices. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. DNA gel electrophoresis: the reptation model(s).

    Science.gov (United States)

    Slater, Gary W

    2009-06-01

    DNA gel electrophoresis has been the most important experimental tool to separate DNA fragments for several decades. The introduction of PFGE in the 1980s and capillary gel electrophoresis in the 1990s made it possible to study, map and sequence entire genomes. Explaining how very large DNA molecules move in a gel and why PFGE is needed to separate them has been an active field of research ever since the launch of the journal Electrophoresis. This article presents a personal and historical overview of the development of the theory of gel electrophoresis, focusing on the reptation model, the band broadening mechanisms, and finally the factors that limit the read length and the resolution of electrophoresis-based sequencing systems. I conclude with a short discussion of some of the questions that remain unanswered.

  8. 31 CFR 363.28 - Does Public Debt reserve the right to require that any TreasuryDirect ® transaction be conducted...

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false Does Public Debt reserve the right to... Provisions Governing Securities Held in TreasuryDirect § 363.28 Does Public Debt reserve the right to require that any TreasuryDirect ® transaction be conducted in paper form? We reserve the right to require any...

  9. Pulsed-field gel electrophoresis of bacterial chromosomes.

    Science.gov (United States)

    Mawer, Julia S P; Leach, David R F

    2013-01-01

    The separation of fragments of DNA by agarose gel electrophoresis is integral to laboratory life. Nevertheless, standard agarose gel electrophoresis cannot resolve fragments bigger than 50 kb. Pulsed-field gel electrophoresis is a technique that has been developed to overcome the limitations of standard agarose gel electrophoresis. Entire linear eukaryotic chromosomes, or large fragments of a chromosome that have been generated by the action of rare-cutting restriction endonucleases, can be separated using this technique. As a result, pulsed-field gel electrophoresis has many applications, from karyotype analysis of microbial genomes, to the analysis of chromosomal strand breaks and their repair intermediates, to the study of DNA replication and the identification of origins of replication. This chapter presents a detailed protocol for the preparation of Escherichia coli chromosomal DNA that has been embedded in agarose plugs, digested with the rare-cutting endonuclease NotI, and separated by contour-clamped homogeneous field electrophoresis. The principles in this protocol can be applied to the separation of all fragments of DNA whose size range is between 40 kb and 1 Mb.

  10. Rights reserved to parliament in connection with the atomic energy laws

    International Nuclear Information System (INIS)

    Loeffler, K.

    1985-01-01

    The peaceful use of nuclear energy is a key problem in the field of force created by the counter vailing interests of the economy and ecology, a problem that is a first-rate challenge to the institutions of our constitutional state. This book is intended to explain the constitutional key problem in the field of nuclear energy utilization: Does the institution ''parliament'' - primarily the Federal Parliament which by our Basic Law is assigned the function of an ''institutional centre of political affairs'' - accept the challenge or does it evade the responsibility for problems relating to the principles of our society. The author primarily reveals and discusses the task and rights to be reserved to parliament within the vast field of governmental activities, so that the large framework of legislative means of impact is left out of consideration, although some individual aspects now and then are considered as additional items which contribute to explain the point discussed. The constitutional standard is the rights reserved to parliament which, according to the theory of material and essential matters developed by the Federal Constitutional Court, include vital decisions with impact on the future development of our society, and not only problems relating to the Basic Law, as was hitherto accepted. This extended approach applies to problems solvable by legislative means. (orig./HP) [de

  11. Nonradioactive telomerase activity assay by microchip electrophoresis: privileges to the classical gel electrophoresis assay.

    Science.gov (United States)

    Zhelev, Zhivko; Bakalova, Rumiana; Ewis, Ashraf; Ohba, Hideki; Ishikawa, Mitsuru; Baba, Yoshinobu

    2005-08-01

    The present study accents on the privileges of microchip-based electrophoresis to the conventional gel electrophoresis in separation of telomerase repeat amplification protocol/polymerase chain reaction (PCR) ladder products obtained in telomerase-catalyzed reaction in cancer cells. We try to clarify the interpretation of the results obtained by both electrophoretic procedures and to avoid misinterpretation as a result of PCR-dependent artefacts.

  12. Speciation of iodine-containing proteins in Nori seaweed by gel electrophoresis laser ablation ICP-MS.

    Science.gov (United States)

    Romarís-Hortas, V; Bianga, J; Moreda-Piñeiro, A; Bermejo-Barrera, P; Szpunar, J

    2014-09-01

    An analytical approach providing an insight into speciation of iodine in water insoluble fraction of edible seaweed (Nori) was developed. The seaweed, harvested in the Galician coast (Northwestern Spain), contained 67.7±1.3 μg g(-1) iodine of which 25% was water soluble and could be identifies as iodide. Extraction conditions of water insoluble residue using urea, NaOH, SDS and Triton X-100 were investigated. The protein pellets obtained in optimized conditions (after precipitation of urea extracts with acetone), were digested with trypsin and protease XIV. Size exclusion chromatography-ICP-MS of both enzymatic digests demonstrated the occurrence of iodoaminoacids putatively present in proteins. Intact proteins could be separated by gel electrophoresis after an additional extraction of the protein extract with phenol. Sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS PAGE) with laser ablation ICP-MS detection of (127)I indicated the presence of iodine in protein bands corresponding to molecular masses of 110 kDa, 40 kDa, 27 kDa, 20 kDa and 10 kDa. 2D IEF-SDS PAGE with laser ablation ICP-MS (127)I imaging allowed the detection of 5 iodine containing protein spots in the alkaline pI range. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Simultaneous determination of phenylethanoid glycosides and aglycones by capillary zone electrophoresis with running buffer modifier.

    Science.gov (United States)

    Dong, Shuqing; Gao, Ruibin; Yang, Yan; Guo, Mei; Ni, Jingman; Zhao, Liang

    2014-03-15

    Although the separation efficiency of capillary electrophoresis (CE) is much higher than that of other chromatographic methods, it is sometimes difficult to adequately separate the complex ingredients in biological samples. This article describes how one effective and simple way to develop the separation efficiency in CE is to add some modifiers to the running buffer. The suitable running buffer modifier β-cyclodextrin (β-CD) was explored to fast and completely separate four phenylethanoid glycosides and aglycones (homovanillyl alcohol, hydroxytyrosol, 3,4-dimethoxycinnamic acid, and caffeic acid) in Lamiophlomis rotata (Lr) and Cistanche by capillary zone electrophoresis with ultraviolet (UV) detection. It was found that when β-CD was used as running buffer modifier, a baseline separation of the four analytes could be accomplished in less than 20 min and the detection limits were as low as 10(-3) mg L(-1). Other factors affecting the CE separation, such as working potential, pH value and ionic strength of running buffer, separation voltage, and sample injection time, were investigated extensively. Under the optimal conditions, a successful practical application on the determination of Lr and Cistanche samples confirmed the validity and practicability of this method. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Gel electrophoresis of inorganic cations

    International Nuclear Information System (INIS)

    Schoenhofer, F.; Grass, F.

    1978-01-01

    In order to be able to separate the largest possible amounts of substance, polyacryl amide gel (PAA) and silica gel are used as carrier for the electrophoresis. Milligramme quantities can easily be separated on PAA gel plates. Electrophoretic ion focussing considerably improves it. Separations of Sr/Y and lanthanoids were carried out. The behaviour of the readily soluble complexing agent acids on silica gel thin layers was minutely investigated and an interpretation of the focussing effect was derived. The conditions for separating radionuclides were optimized. A further improved separation can be achieved by a time sequence combination of normal electrophoresis and ion focussing. Selective isolation methods are advantageous to determine radionuclide traces in environmental samples. The selective adsorption on preformed deposits was transferred to electrophoresis. After pre-investigations on silica gel layers, strontium and barium could also be retained on PAA gel and radium on strontium sulphate in PAA, whereas the disturbing calcium can easily pass through. Cesium can also be retained by prussian blue in the electrophoresis. (orig.) [de

  15. Bioprocessing: Prospects for space electrophoresis

    Science.gov (United States)

    Bier, M.

    1977-01-01

    The basic principles of electrophoresis are reviewed in light of its past contributions to biology and medicine. The near-zero gravity environment of orbiting spacecraft may present some unique advantages for a variety of processes, by abolishing the major source of convection in fluids. As the ground-based development of electrophoresis was heavily influenced by the need to circumvent the effects of gravity, this process should be a prime candidate for space operation. Nevertheless, while a space facility for electrophoresis may overcome the limitations imposed by gravity, it will not necessarily overcome all problems inherent in electrophoresis. These are, mainly, electroosmosis and the dissipation of the heat generated by the electric field. The NASA program has already led to excellent coatings to prevent electroosmosis, while the need for heat dissipation will continue to impose limits on the actual size of equipment. It is also not excluded that, once the dominant force of gravity is eliminated, disturbances in fluid stability may originate from weaker forces, such as surface tension.

  16. Echocardiographic assessment of right ventricular contractile reserve in patients with pulmonary hypertension.

    Science.gov (United States)

    Almeida, Ana Rita; Loureiro, Maria José; Lopes, Liliana; Cotrim, Carlos; Lopes, Luís; Repolho, Débora; Pereira, Hélder

    2014-03-01

    Right ventricular function is a major determinant of prognosis in pulmonary hypertension. The aim of this study was to assess and compare right ventricular contractile reserve in healthy subjects (controls) and in subjects with pulmonary hypertension (cases). In this prospective study of seven cases and seven controls undergoing treadmill stress echocardiography, right ventricular S-wave velocity, tricuspid annular plane systolic excursion (TAPSE), right ventricular fractional area change (RVFAC) and stroke volume index were assessed at rest and with exercise. The increase in each parameter between rest and exercise for cases and controls was analyzed and the magnitude of change in each parameter with exercise between cases and controls was compared. A significant increase in S-wave velocity was observed in cases (rest: 9.4 ± 3.1; exercise: 13.7 ± 4.8 cm/s [p < 0.05]). In controls there was a statistically significant increase in S-wave velocity (12.9 ± 2.3 to 23.0 ± 7.2 cm/s [p < 0.005]), TAPSE (25.7 ± 2.4 to 31.0 ± 3.5 mm [p < 0.05]) and RVFAC (53.8 ± 14.7% to 64.4 ± 9.9% [p < 0.005]). The magnitude of change in S-wave velocity (cases: 4.3 ± 3.3; controls: 10.1 ± 5.5 cm/s [p < 0.05]), TAPSE (cases: 0.6 ± 2.5; controls: 5.3 ± 3.8 mm [p < 0.05]) and RVFAC (cases: -0.4 ± 11.8; controls: 10.6 ± 5.9% [p < 0.05]) was significantly different between cases and controls. S-wave velocity, TAPSE and RVFAC increased significantly with exercise in controls. S-wave velocity was the only parameter that showed a significant increase in cases, although the magnitude of this increase was significantly less than in controls. Copyright © 2013 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  17. Electrophoresis in space at zero gravity

    Science.gov (United States)

    Bier, M.; Snyder, R. S.

    1974-01-01

    Early planning for manufacturing operations in space include the use of electrophoresis for purification and separation of biological materials. Greatly simplified electrophoresis apparatus have been flown in the Apollo 14 and 16 missions to test the possibility of stable liquid systems in orbit. Additionally, isoelectric focusing and isotachophoresis are of particular interest as they offer very high resolution and have self-sharpening boundaries. The value of possible space electrophoresis is substantial. For example, present technology permits large fractionation of only a few of blood proteins many fractions, and separated cell populations are needed for research.

  18. Combining electrophoresis with detection under ultraviolet light and multiple ultrafiltration for isolation of humic fluorescence fractions.

    Science.gov (United States)

    Trubetskaya, Olga E; Shaloiko, Lubov A; Demin, Dmitrii V; Marchenkov, Victor V; Proskuryakov, Ivan I; Coelho, Christian; Trubetskoj, Oleg A

    2011-04-01

    Polyacrylamide gel electrophoresis of chernozem soil humic acids (HAs) followed by observation under UV (312 nm) excitation light reveals new low molecular weight (MW) fluorescent fractions. Ultrafiltration of HAs sample in 7 M urea on a membrane of low nominal MW retention (NMWR, 5 kDa) was repetitively used for separation of fluorescent and non-fluorescent species. Thirty ultrafiltrates and the final retentate R were obtained. Fluorescence maxima of separate ultrafiltrates were different and non-monotonously changed in the range of 475-505 nm. Fluorescence maxima of less than 490 nm were detected only in the four first utrafiltrates. For further physical-chemical analyses all utrafiltrates were combined into a fraction called UFchernozem soil HAs complex. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Enantioseparations of amino acids by capillary array electrophoresis with 532 nm laser induced fluorescence detection.

    Science.gov (United States)

    Liu, Kaiying; Wang, Li

    2013-06-21

    Capillary array electrophoresis (CAE) is a promising technique for multiple enantiomeric separations. Carboxytetramethylrhodamine succinimidyl ester (TAMRA SE), a rhodamine-core fluorescent probe, has rarely been applied as an original precolumn derivatization reagent for chiral amino acid (AA) analysis so far. For these purposes, high-throughput enantiomeric separations of 12 TAMRA SE-AAs by a home-made 532 nm CAE-LIF scanner are presented. The effect of cyclodextrins (CDs) and a variety of organic modifiers was quickly investigated. Baseline separations were achieved in 100 mM Tris-borate buffer (pH 10.0) containing 2 mM β-CD and 10 mM hexamethylenediamine (HDA). Multiple determination of the enantiomeric excess (ee) in non-racemic mixtures of alanine is successfully presented. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Comparison of the capillary and agarose electrophoresis based multiple locus VNTR (variable number of tandem repeats) analysis (MLVA) on Mycobacterium bovis isolates.

    Science.gov (United States)

    Jenkins, A O; Venter, E H; Hutamo, K; Godfroid, J

    2010-09-28

    Electrophoretic techniques that can be used for genotyping of bacterial pathogens ranges from manual, low-cost, agarose gels to high-throughput capillary electrophoresis sequencing machines. These two methods are currently employed in the electrophoresis of PCR products used in multiple locus VNTR (variable number of tandem repeats) analysis (MLVA), i.e. the agarose electrophoresis (AE) and the capillary electrophoresis (CE). Some authors have suggested that clusters generated by AE are less reliable than those generated by CE and that the latter is a more sensitive technique than the former when typing Mycobacterium tuberculosis complex (MTC) isolates. Because such a claim could have significant consequences for investigators in this field, a comparison was made on 19 Belgian Mycobacterium bovis strains which had previously been genotyped using CE VNTR analysis. The VNTR profiles of the CE VNTR analysis were compared with those obtained by AE VNTR analysis at 14 VNTR loci. Our results indicated that there were no differences in copy numbers at all loci tested when the copy numbers obtained by the AE VNTR analysis were compared with those obtained by CE VNTR analysis. The use of AE VNTR analysis in mycobacterial genotyping does not alter the sensitivity of the MLVA technique compared with the CE VNTR analysis. The AE VNTR can therefore be regarded as a viable alternative in moderately equipped laboratories that cannot afford the expensive equipment required for CE VNTR analysis and data obtained by AE VNTR analysis can be shared between laboratories which use the CE VNTR method. (c) 2010 Elsevier B.V. All rights reserved.

  1. Electrophoresis in strong electric fields.

    Science.gov (United States)

    Barany, Sandor

    2009-01-01

    Two kinds of non-linear electrophoresis (ef) that can be detected in strong electric fields (several hundred V/cm) are considered. The first ("classical" non-linear ef) is due to the interaction of the outer field with field-induced ionic charges in the electric double layer (EDL) under conditions, when field-induced variations of electrolyte concentration remain to be small comparatively to its equilibrium value. According to the Shilov theory, the non-linear component of the electrophoretic velocity for dielectric particles is proportional to the cubic power of the applied field strength (cubic electrophoresis) and to the second power of the particles radius; it is independent of the zeta-potential but is determined by the surface conductivity of particles. The second one, the so-called "superfast electrophoresis" is connected with the interaction of a strong outer field with a secondary diffuse layer of counterions (space charge) that is induced outside the primary (classical) diffuse EDL by the external field itself because of concentration polarization. The Dukhin-Mishchuk theory of "superfast electrophoresis" predicts quadratic dependence of the electrophoretic velocity of unipolar (ionically or electronically) conducting particles on the external field gradient and linear dependence on the particle's size in strong electric fields. These are in sharp contrast to the laws of classical electrophoresis (no dependence of V(ef) on the particle's size and linear dependence on the electric field gradient). A new method to measure the ef velocity of particles in strong electric fields is developed that is based on separation of the effects of sedimentation and electrophoresis using videoimaging and a new flowcell and use of short electric pulses. To test the "classical" non-linear electrophoresis, we have measured the ef velocity of non-conducting polystyrene, aluminium-oxide and (semiconductor) graphite particles as well as Saccharomice cerevisiae yeast cells as a

  2. Raman spectroscopy and capillary electrophoresis applied to forensic colour inkjet printer inks analysis.

    Science.gov (United States)

    Król, Małgorzata; Karoly, Agnes; Kościelniak, Paweł

    2014-09-01

    Forensic laboratories are increasingly engaged in the examination of fraudulent documents, and what is important, in many cases these are inkjet-printed documents. That is why systematic approaches to inkjet printer inks comparison and identification have been carried out by both non-destructive and destructive methods. In this study, micro-Raman spectroscopy and capillary electrophoresis (CE) were applied to the analysis of colour inkjet printer inks. Micro-Raman spectroscopy was used to study the chemical composition of colour inks in situ on a paper surface. It helps to characterize and differentiate inkjet inks, and can be used to create a spectra database of inks taken from different cartridge brands and cartridge numbers. Capillary electrophoresis in micellar electrophoretic capillary chromatography mode was applied to separate colour and colourless components of inks, enabling group identification of those components which occur in a sufficient concentration (giving intensive peaks). Finally, on the basis of the obtained results, differentiation of the analysed inks was performed. Twenty-three samples of inkjet printer inks were examined and the discriminating power (DP) values for both presented methods were established in the routine work of experts during the result interpretation step. DP was found to be 94.0% (Raman) and 95.6% (CE) when all the analysed ink samples were taken into account, and it was 96.7% (Raman) and 98.4% (CE), when only cartridges with different index numbers were considered. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  3. Analytical biotechnology: Capillary electrophoresis and chromatography

    International Nuclear Information System (INIS)

    Horvath, C.; Nikelly, J.G.

    1990-01-01

    The papers describe the separation, characterization, and equipment required for the electrophoresis or chromatography of cyclic nucleotides, pharmaceuticals, therapeutic proteins, recombinant DNA products, pheromones, peptides, and other biological materials. One paper, On-column radioisotope detection for capillary electrophoresis, has been indexed separately for inclusion on the data base

  4. Quantitation of yeast total proteins in sodium dodecyl sulfate-polyacrylamide gel electrophoresis sample buffer for uniform loading.

    Science.gov (United States)

    Sheen, Hyukho

    2016-04-01

    Proteins in sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) sample buffer are difficult to quantitate due to SDS and reducing agents being in the buffer. Although acetone precipitation has long been used to clean up proteins from detergents and salts, previous studies showed that protein recovery from acetone precipitation varies from 50 to 100% depending on the samples tested. Here, this article shows that acetone precipitates proteins highly efficiently from SDS-PAGE sample buffer and that quantitative recovery is achieved in 5 min at room temperature. Moreover, precipitated proteins are resolubilized with urea/guanidine, rather than with SDS. Thus, the resolubilized samples are readily quantifiable with Bradford reagent without using SDS-compatible assays. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Is pulsed electric field still effective for RNA separation in capillary electrophoresis?

    Science.gov (United States)

    Li, Zhenqing; Dou, Xiaoming; Ni, Yi; Chen, Qinmiao; Cheng, Shuyi; Yamaguchi, Yoshinori

    2012-03-16

    Pulsed field capillary electrophoresis (PFCE) is a predominant technique to cope with difficulties in resolving large DNA strands, yet it is still unclear whether pulsed electric field is effective for the separation of higher mass RNA. In this paper we focused on the role of pulsed electric field in large RNA fragments analysis by comparing RNA separation performance in PFCE with that in constant field CE. Separation performance in terms of migration mobility, plate numbers, resolution, and selectivity has been tested for the analysis of RNA from 0.1 to 10.0 kilo nucleotide (knt) under different electrophoretic conditions. Denaturation, important to obtain uniform and identifiable peaks, was accomplished by heating the sample in 4.0M urea prior to analysis and the presence of 4.0M urea in the electrophoresis buffer. Results demonstrate that unlike DNA in PFCE, the pulsed electric field mainly affects the separation performance of RNA between 0.4 and 2.0 knt. The migration mobility of long RNA fragments is not a strong function of modulation depth and pulsed frequency. Moreover, the logarithm of RNA mobility is almost inversely proportional to the logarithm of molecule size up to 6.0 knt with correlation coefficient higher than 0.99 in all the polymer concentrations measured here. Resonance frequency of RNA in PFCE was also observed. While these initial experiments show no distinct advantages of using PFCE for RNA separation, they do take further step toward characterizing the migration behavior of RNA under pulsed field conditions. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. Agarose gel electrophoresis and polyacrylamide gel electrophoresis for visualization of simple sequence repeats.

    Science.gov (United States)

    Anderson, James; Wright, Drew; Meksem, Khalid

    2013-01-01

    In the modern age of genetic research there is a constant search for ways to improve the efficiency of plant selection. The most recent technology that can result in a highly efficient means of selection and still be done at a low cost is through plant selection directed by simple sequence repeats (SSRs or microsatellites). The molecular markers are used to select for certain desirable plant traits without relying on ambiguous phenotypic data. The best way to detect these is the use of gel electrophoresis. Gel electrophoresis is a common technique in laboratory settings which is used to separate deoxyribonucleic acid (DNA) and ribonucleic acid (RNA) by size. Loading DNA and RNA onto gels allows for visualization of the size of fragments through the separation of DNA and RNA fragments. This is achieved through the use of the charge in the particles. As the fragments separate, they form into distinct bands at set sizes. We describe the ability to visualize SSRs on slab gels of agarose and polyacrylamide gel electrophoresis.

  7. Protein electrophoresis - serum

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003540.htm Protein electrophoresis - serum To use the sharing features on ... JavaScript. This lab test measures the types of protein in the fluid (serum) part of a blood ...

  8. Analysis of compositional monosaccharides in fungus polysaccharides by capillary zone electrophoresis.

    Science.gov (United States)

    Hu, Yuanyuan; Wang, Tong; Yang, Xingbin; Zhao, Yan

    2014-02-15

    A rapid analytical method of capillary zone electrophoresis (CZE) was established for the simultaneous separation and determination of 10 monosaccharides (aldoses and uronic acids). The monosaccharides were labeled with 1-phenyl-3-methyl-5-pyrazolone (PMP), and subsequently separated using an uncoated capillary (50 μm i.d. × 58.5 cm) and detected by UV at 245 nm with pH 11.0, 175 mM borate buffer at voltage 20 kV and capillary temperature 25 °C by CZE. The 10 PMP-labeled monosaccharides were rapidly baseline separated within 20 min. The optimized CZE method was successfully applied to the simultaneous separation and identification of the monosaccharide composition in Termitomyces albuminosus polysaccharides (TAPs) and Panus giganteus polysaccharides (PGPs). The quantitative recovery of the component monosaccharides in the fungus polysaccharides was in the range of 92.0-101.0% and the CV value was lower than 3.5%. The results demonstrate that the proposed CZE method is precise and practical for the monosaccharide analysis of fungus polysaccharides. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Rapid capillary electrophoresis approach for the quantification of ewe milk adulteration with cow milk.

    Science.gov (United States)

    Trimboli, Francesca; Morittu, Valeria Maria; Cicino, Caterina; Palmieri, Camillo; Britti, Domenico

    2017-10-13

    The substitution of ewe milk with more economic cow milk is a common fraud. Here we present a capillary electrophoresis method for the quantification of ewe milk in ovine/bovine milk mixtures, which allows for the rapid and inexpensive recognition of ewe milk adulteration with cow milk. We utilized a routine CE method for human blood and urine proteins analysis, which fulfilled the separation of skimmed milk proteins in alkaline buffer. Under this condition, ovine and bovine milk exhibited a recognizable and distinct CE protein profiles, with a specific ewe peak showing a reproducible migration zone in ovine/bovine mixtures. Based on ewe specific CE peak, we developed a method for ewe milk quantification in ovine/bovine skimmed milk mixtures, which showed good linearity, precision and accuracy, and a minimum amount of detectable fraudulent cow milk equal to 5%. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. 21 CFR 862.2485 - Electrophoresis apparatus for clinical use.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electrophoresis apparatus for clinical use. 862.2485 Section 862.2485 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... Instruments § 862.2485 Electrophoresis apparatus for clinical use. (a) Identification. An electrophoresis...

  11. Practical capillary electrophoresis

    CERN Document Server

    Weinberger, Robert

    2000-01-01

    In the 1980s, capillary electrophoresis (CE) joined high-performance liquid chromatography (HPLC) as the most powerful separation technique available to analytical chemists and biochemists. Published research using CE grew from 48 papers in the year of commercial introduction (1988) to 1200 in 1997. While only a dozen major pharmaceutical and biotech companies have reduced CE to routine practice, the applications market is showing real or potential growth in key areas, particularly in the DNA marketplace for genomic mapping and forensic identification. For drug development involving small molecules (including chiral separations), one CE instrument can replace 10 liquid chromatographs in terms of speed of analysis. CE also uses aqueous rather than organic solvents and is thus environmentally friendlier than HPLC. The second edition of Practical Capillary Electrophoresis has been extensively reorganized and rewritten to reflect modern usage in the field, with an emphasis on commercially available apparatus and ...

  12. Misleading presentation of haemoglobin electrophoresis data | Adu ...

    African Journals Online (AJOL)

    Haemoglobinopathies are common in sub-Saharan Africa. As such haemoglobin electrophoresis are required to inform clinical decision making. However, haemoglobin electrophoresis is an assay that detects protein at either alkaline or acidic pH. Such assays do not interrogate gene sequences but rather the product of a ...

  13. Comparison of lipoprotein electrophoresis and apolipoprotein e genotyping in investigating dysbetalipoproteinemia

    International Nuclear Information System (INIS)

    Ahmed, F.; Kadiki, A.E.

    2017-01-01

    Dysbetalipoproteinemia is often associated with apolipoprotein E2E2 homozygosity; however, lipoprotein electrophoresis may also be used to assist in the diagnosis. The aim of this study was to compare apolipoprotein E (apo E) genotyping and lipoprotein electrophoresis in investigating dysbetalipoproteinemia. Data were collected over a three-year period from a lipid clinic in a tertiary referral centre and reviewed for apo E genotyping and lipoprotein electrophoresis. Sixty-two patients had both apo E genotyping and lipoprotein electrophoresis. Of these, 16 patients showed broad beta band on electrophoresis. However, only 3 of them had apo E2E2 homozygosity on genotyping. Lipoprotein electrophoresis and apo E genotyping results showed poor concordance. This was primarily due to visual interpretation error of lipoprotein electrophoresis which may over diagnose dysbetalipoproteinemia. (author)

  14. Comparison of Lipoprotein Electrophoresis and Apolipoprotein E Genotyping in Investigating Dysbetalipoproteinemia.

    Science.gov (United States)

    Ahmed, Farhan; El-Kadiki, Alia; Gibbons, Stephen

    2017-06-01

    Dysbetalipoproteinemia is often associated with apolipoprotein E2E2 homozygosity; however, lipoprotein electrophoresis may also be used to assist in the diagnosis. The aim of this study was to compare apolipoprotein E (apo E) genotyping and lipoprotein electrophoresis in investigating dysbetalipoproteinemia. Data were collected over a three-year period from a lipid clinic in a tertiary referral centre and reviewed for apo E genotyping and lipoprotein electrophoresis. Sixty-two patients had both apo E genotyping and lipoprotein electrophoresis. Of these, 16 patients showed broad beta band on electrophoresis. However, only 3 of them had apo E2E2 homozygosity on genotyping. Lipoprotein electrophoresis and apo E genotyping results showed poor concordance. This was primarily due to visual interpretation error of lipoprotein electrophoresis which may over diagnose dysbetalipoproteinemia.

  15. Conducting Polymer Electrodes for Gel Electrophoresis

    OpenAIRE

    Bengtsson, Katarina; Nilsson, Sara; Robinson, Nathaniel D

    2014-01-01

    In nearly all cases, electrophoresis in gels is driven via the electrolysis of water at the electrodes, where the process consumes water and produces electrochemical by-products. We have previously demonstrated that p-conjugated polymers such as poly(3,4-ethylenedioxythiophene) (PEDOT) can be placed between traditional metal electrodes and an electrolyte to mitigate electrolysis in liquid (capillary electroosmosis/electrophoresis) systems. In this report, we extend our previous result to gel ...

  16. In situ photo-immobilised pH gradient isoelectric focusing and zone electrophoresis integrated two-dimensional microfluidic chip electrophoresis for protein separation

    International Nuclear Information System (INIS)

    Lin, Fengmin; Yu, Shiyong; Gu, Le; Zhu, Xuetao; Wang, Jianshe; Zhu, Han; Lu, Yi; Wang, Yihua; Deng, Yulin; Geng, Lina

    2015-01-01

    A method is introduced for open-column photo-induced site-selective immobilization of pH gradients in a layer of PEG-methacrylate in a multi-dimensional microfluidic chip for use in electrophoresis. It has several attractive features: (a) mixtures of fluorescently labelled proteins carbonic anhydrase, catalase and myoglobin in their native state can be separated by pH-gradient isoelectric focusing (IEF) and zone electrophoresis (CZE) using integrated 2D chip electrophoresis; (b) compared to strip packing or monolithic photo-immobilization, it overcomes the shortcomings of free carrier ampholyte-based 2D chip electrophoresis in an easy way; (c) larger amount of sample can be loaded into the open column-mode electrophoresis (d) immobilized pH gradients can be re-used and the chip can be recycled; (e) a multilayer 3D pH gradient is established by a layer-by-layer assembly technique to further increase the separation capacity. In our perception, this strategy has a large potential in microfluidic chip-based separation schemes because of its simplicity, separation power, re-usability, and separation capacity. (author)

  17. Simultaneous determination of rifabutin and human serum albumin in pharmaceutical formulations by capillary electrophoresis.

    Science.gov (United States)

    Ermolenko, Yu; Anshakova, A; Osipova, N; Kamentsev, M; Maksimenko, O; Balabanyan, V; Gelperina, S

    Capillary zone electrophoresis (CZE) was used for determination of rifabutin (RFB), an anti-tuberculosis antibiotic drug, in various pharmaceutical formulations. Apart from that, simultaneous determination of RFB and human serum albumin (HSA) was performed. Electrophoretic behaviour of RFB was examined at various pH levels. CE conditions: a quartz capillary tube (internal diameter 75mm, effective length 50cm, total length 60cm), the capillary temperature was 25°С, the voltage applied to the capillary tube was +20kV, the UV detection wavelength was 214nm, hydrodynamic injection of the sample was performed at 30mbar for 5s, tetraborate buffer solution (0.01М, рН9.2). The obtained results are characterized by high efficiency (number of theoretical plates up to 260,000) and sufficient sensitivity (LOQ starting from 0.02μg/ml for RFB). The obtained data are in good accord with both HPLC results (for RFB) and spectrophotometry (for HSA). Copyright © 2017 Elsevier Inc. All rights reserved.

  18. DNA Sequencing by Capillary Electrophoresis

    Science.gov (United States)

    Karger, Barry L.; Guttman, Andras

    2009-01-01

    Sequencing of human and other genomes has been at the center of interest in the biomedical field over the past several decades and is now leading toward an era of personalized medicine. During this time, DNA sequencing methods have evolved from the labor intensive slab gel electrophoresis, through automated multicapillary electrophoresis systems using fluorophore labeling with multispectral imaging, to the “next generation” technologies of cyclic array, hybridization based, nanopore and single molecule sequencing. Deciphering the genetic blueprint and follow-up confirmatory sequencing of Homo sapiens and other genomes was only possible by the advent of modern sequencing technologies that was a result of step by step advances with a contribution of academics, medical personnel and instrument companies. While next generation sequencing is moving ahead at break-neck speed, the multicapillary electrophoretic systems played an essential role in the sequencing of the Human Genome, the foundation of the field of genomics. In this prospective, we wish to overview the role of capillary electrophoresis in DNA sequencing based in part of several of our articles in this journal. PMID:19517496

  19. Separation of oligopeptides, nucleobases, nucleosides and nucleotides using capillary electrophoresis/electrochromatography with sol-gel modified inner capillary wall.

    Science.gov (United States)

    Svobodová, Jana; Kofroňová, Olga; Benada, Oldřich; Král, Vladimír; Mikšík, Ivan

    2017-09-29

    The aim of this article is to study the modification of an inner capillary wall with sol-gel coating (pure silica sol-gel or silica sol-gel containing porphyrin-brucine conjugate) and determine its influence on the separation process using capillary electrophoresis/electrochromatography method. After modification of the inner capillary surface the separation of analytes was performed using two different phosphate buffers (pH 2.5 and 9.0) and finally the changes in electrophoretic mobilities of various samples were calculated. To confirm that the modification of the inner capillary surface was successful, the parts of the inner surfaces of capillaries were observed using scanning electron microscopy. The analytes used as testing samples were oligopeptides, nucleosides, nucleobases and finally nucleotides. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Urine protein electrophoresis test

    Science.gov (United States)

    Urine protein electrophoresis; UPEP; Multiple myeloma - UPEP; Waldenström macroglobulinemia - UPEP; Amyloidosis - UPEP ... special paper and apply an electric current. The proteins move and form visible bands. These reveal the ...

  1. Disparity between Multilocus Enzyme Electrophoresis, Microsatellite Markers and Pulsed-Field Gel Electrophoresis in epidemiological tracking of Candida albicans.

    Science.gov (United States)

    Boriollo, Marcelo Fabiano Gomes; Dias, Ricardo Antunes; Fiorini, João Evangelista; Oliveira, Nelma de Mello Silva; Spolidório, Denise Madalena Palomari; de Souza, Henrique Marques Barbosa; Figueira, Antonio Vargas de Oliveira; Pizzirani-Kleiner, Aline Aparecida

    2010-09-01

    with similarity and grouping analysis. Therefore, the use of genotyping systems that give results which offer minimum disparity, or the combination of the results of these systems, can provide greater security and consistency in the determination of strains and their genetic relationships. (c) 2010 Elsevier B.V. All rights reserved.

  2. Single-cell microgel electrophoresis: an in vitro assay of radiosensitivity

    International Nuclear Information System (INIS)

    Deeley, J.O.T.; Moore, J.L.

    1993-01-01

    The results obtained by a microgel electrophoresis are comparable to conventional gel electrophoresis and elution techniques (Singh et al, 1989), DNA precipitation, alkali unwinding and cell clonogenicity assays (Olive et al, 1990). Since single cells are assessed, microgel electrophoresis is particularly appropriate for end-points such as the intercell variation in response. The simplicity, low cost and rapidity of microgel electrophoresis compared with other assays makes it particularly attractive for assessing the effects on DNA of radiation and other genotoxic agents on the general population. (Author)

  3. Capillary electrophoresis of chitooligosaccharides in acidic solution: simple determination using a quaternary-ammonium-modified column and indirect photometric detection with crystal violet.

    Science.gov (United States)

    Hattori, Toshiaki; Anraku, Nobuhiro; Kato, Ryo

    2010-02-01

    Five chitosan oligosaccharides were separated in acidic aqueous solution by capillary electrophoresis (CE) with indirect photometric detection using a positively coated capillary. Electrophoretic mobility of the chitooligosaccharides (COSs) depended on the number of monomer units in acidic aqueous solution, similar to other polyelectrolyte oligomers. The separation was developed in nitric acid aqueous solution at pH 3.0 with 1 mM Crystal Violet, using a capillary positively coated with N-trimethoxypropyl-N,N,N-trimethylammonium chloride. The limit of the detection for chitooligosaccharides with two to six saccharide chains was less than 5 microM. CE determination of an enzymatically hydrolyzed COS agreed with results from HPLC. 2009 Elsevier B.V. All rights reserved.

  4. Capillary electrophoresis: principles and applications in illicit drug analysis.

    Science.gov (United States)

    Tagliaro, F; Turrina, S; Smith, F P

    1996-02-09

    Capillary electrophoresis, which appeared in the early 1980s, is now rapidly expanding into many scientific disciplines, including analytical chemistry, biotechnology and biomedical and pharmaceutical sciences. In capillary electrophoresis,electrokinetic separations are carried out in tiny capillaries at high voltages (10-30 kV), thus obtaining high efficiencies (N > 10(5)) and excellent mass sensitivities (down to 10(-18)-10(-20) moles). The main features of capillary electrophoresis are: versatility of application (from inorganic ions to large DNA fragments), use of different separation modes with different selectivity, extremely low demands on sample volume, negligible running costs, possibility of interfacing with different detection systems, ruggedness and simplicity of instrumentation. Capillary electrophoresis applications in forensic sciences have appeared only recently, but are now rapidly growing, particularly in forensic toxicology. The present paper briefly describes the basic principles of capillary electrophoresis, from both the instrumental and analytical points of view. Furthermore, the main applications in the analysis of illicit/controlled drugs in both illicit preparations and biological samples are presented and discussed (43 references). It is concluded that the particular separation mechanism and the high complementarity of this technique to chromatography makes capillary electrophoresis a new powerful tool of investigation in the hands of forensic toxicologists.

  5. Electrophoresis in the analysis of natural and industrial ob ects

    International Nuclear Information System (INIS)

    Stepanov, A.V.; Korchemnaya, E.K.

    1979-01-01

    Given is a brief review on practical application of electrophoresis in the analysis of natural and industrial objects. Suggested are expressiVe methods of thorium, uranium and rare earth elements separation in minerals by electrophoresis. The possibility of quantitative determination of rare earth elements in meteorites by the method of electromigration is shown. By means of electrophoresis identified are forms of radioruthenium in a sea water. Shown is the electrophoresis application for reactor loop water analysis, for environment contamination study, for determination of some rare earth yield in reactions of uranium fission by heavy ions

  6. DNA agarose gel electrophoresis for antioxidant analysis: Development of a quantitative approach for phenolic extracts.

    Science.gov (United States)

    Silva, Sara; Costa, Eduardo M; Vicente, Sandra; Veiga, Mariana; Calhau, Conceição; Morais, Rui M; Pintado, Manuela E

    2017-10-15

    Most of the fast in vitro assays proposed to determine the antioxidant capacity of a compound/extract lack either biological context or employ complex protocols. Therefore, the present work proposes the improvement of an agarose gel DNA electrophoresis in order to allow for a quantitative estimation of the antioxidant capacity of pure phenolic compounds as well as of a phenolic rich extract, while also considering their possible pro-oxidant effects. The result obtained demonstrated that the proposed method allowed for the evaluation of the protection of DNA oxidation [in the presence of hydrogen peroxide (H 2 O 2 ) and an H 2 O 2 /iron (III) chloride (FeCl 3 ) systems] as well as for the observation of pro-oxidant activities, with the measurements registering interclass correlation coefficients above 0.9. Moreover, this method allowed for the characterization of the antioxidant capacity of a blueberry extract while demonstrating that it had no perceived pro-oxidant effect. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Analysis of electrophoresis performance

    Science.gov (United States)

    Roberts, G. O.

    1984-01-01

    The SAMPLE computer code models electrophoresis separation in a wide range of conditions. Results are included for steady three dimensional continuous flow electrophoresis (CFE), time dependent gel and acetate film experiments in one or two dimensions and isoelectric focusing in one dimension. The code evolves N two dimensional radical concentration distributions in time, or distance down a CFE chamber. For each time or distance increment, there are six stages, successively obtaining the pH distribution, the corresponding degrees of ionization for each radical, the conductivity, the electric field and current distribution, and the flux components in each direction for each separate radical. The final stage is to update the radical concentrations. The model formulation for ion motion in an electric field ignores activity effects, and is valid only for low concentrations; for larger concentrations the conductivity is, therefore, also invalid.

  8. Preparative electrophoresis of industrial fission product solutions

    International Nuclear Information System (INIS)

    Tret, Joel

    1971-07-01

    The aim of this work is to contribute to the development of the continuous electrophoresis technique while studying its application in the preparative electrophoresis of industrial fission product solutions. The apparatus described is original. It was built for the purposes of the investigation and proved very reliable in operation. The experimental conditions necessary to maintain and supervise the apparatus in a state of equilibrium are examined in detail; their stability is an important factor, indispensable to the correct performance of an experiment. By subjecting an industrial solution of fission products to preparative electrophoresis it is possible, according to the experimental conditions, to prepare carrier-free radioelements of radiochemical purity (from 5 to 7 radioelements): 137 Cs, 90 Sr, 141+144 Ce, 91 Y, 95 Nb, 95 Zr, 103+106 Ru. (author) [fr

  9. Images of gel electrophoresis - RGP caps | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available List Contact us RGP caps Images of gel electrophoresis Data detail Data name Images of gel electrophoresis D...OI 10.18908/lsdba.nbdc00318-05-002 Description of data contents Detailed information and images of gel electrophoresis... of each marker. Data file File name: rgp_caps_electrophoresis_image.zip File URL: ftp://ftp.biosc...iencedbc.jp/archive/rgp-caps/LATEST/rgp_caps_electrophoresis_image.zip File size:... 28.7 MB Simple search URL - Data acquisition method Gel electrophoresis Data analysis method STS markers :

  10. Applications of space-electrophoresis in medicine. [for cellular separations in molecular biology

    Science.gov (United States)

    Bier, M.

    1976-01-01

    The nature of electrophoresis is reviewed and potential advances realizable in the field of biology and medicine from a space electrophoresis facility are examined. The ground-based applications of electrophoresis: (1) characterization of an ionized species; (2) determination of the quantitative composition of a complex mixture; and (3) isolation of the components of a mixture, separation achieved on the basis of the difference in transport rates is reviewed. The electrophoresis of living cells is considered, touching upon the following areas: the separation of T and B lymphocytes; the genetic influence on mouse lymphocyte mobilities; the abnormal production of specific and monoclonal immunoproteins; and the study of cancer. Schematic diagrams are presented of three types of electrophoresis apparatus: the column assembly for the static electrophoresis experiment on the Apollo-Soyuz mission, the continuous flow apparatus used in the same mission and a miniaturized electrophoresis apparatus.

  11. Gel Electrophoresis on a Budget to Dye for

    Science.gov (United States)

    Yu, Julie H.

    2010-01-01

    Gel electrophoresis is one of the most important tools used in molecular biology and has facilitated the entire field of genetic engineering by enabling the separation of nucleic acids and proteins. However, commercial electrophoresis kits can cost up to $800 for each setup, which is cost prohibitive for most classroom budgets. This article…

  12. DNA DAMAGE QUANTITATION BY ALKALINE GEL ELECTROPHORESIS.

    Energy Technology Data Exchange (ETDEWEB)

    SUTHERLAND,B.M.; BENNETT,P.V.; SUTHERLAND, J.C.

    2004-03-24

    Physical and chemical agents in the environment, those used in clinical applications, or encountered during recreational exposures to sunlight, induce damages in DNA. Understanding the biological impact of these agents requires quantitation of the levels of such damages in laboratory test systems as well as in field or clinical samples. Alkaline gel electrophoresis provides a sensitive (down to {approx} a few lesions/5Mb), rapid method of direct quantitation of a wide variety of DNA damages in nanogram quantities of non-radioactive DNAs from laboratory, field, or clinical specimens, including higher plants and animals. This method stems from velocity sedimentation studies of DNA populations, and from the simple methods of agarose gel electrophoresis. Our laboratories have developed quantitative agarose gel methods, analytical descriptions of DNA migration during electrophoresis on agarose gels (1-6), and electronic imaging for accurate determinations of DNA mass (7-9). Although all these components improve sensitivity and throughput of large numbers of samples (7,8,10), a simple version using only standard molecular biology equipment allows routine analysis of DNA damages at moderate frequencies. We present here a description of the methods, as well as a brief description of the underlying principles, required for a simplified approach to quantitation of DNA damages by alkaline gel electrophoresis.

  13. Study of Streptavidin-Modified Quantum Dots by Capillary Electrophoresis

    Czech Academy of Sciences Publication Activity Database

    Stanisavljevic, M.; Janů, L.; Šmerková, K.; Křížková, S.; Pizúrová, Naděžda; Ryvolová, M.; Adam, V.; Hubálek, J.; Kizek, R.

    2013-01-01

    Roč. 76, 7-8 (2013), s. 335-343 ISSN 0009-5893 Institutional support: RVO:68081723 Keywords : Capillary electrophoresis * Gel electrophoresis * Avidin-biotin technology * Oligonucleotide * Nanoparticle * quantum dots Subject RIV: CE - Biochemistry Impact factor: 1.370, year: 2013

  14. Integration of amperometric sensors for microchip capillary electrophoresis application

    International Nuclear Information System (INIS)

    Dicorato, F; Moore, E; Glennon, J

    2011-01-01

    Capillary electrophoresis is a technique for the separation and analysis of chemical compounds. Techniques adopted from the microchip technology knowledge have led to recent developments of electrophoresis system with integration on microchip. Microchip Capillary Electrophoresis (μCE) systems offer a series of advantages as easy integration for Lab-on-a-chip applications, high performance, portability, speed, minimal solvent and sample requirements. A new technological challenge aims at the development of an economic modular microchip capillary electrophoresis systems using separable and independent units concerning the sensor. In this project we worked on the development of an interchangeable amperometric sensor in order to provide a solution to such electrode passivation and facilitating the use of tailored sensors for specific analyte detection besides. Fluidic chips have been machined from cyclic olefin polymer pallets (Zeonor) using a micro-injection molding machine.

  15. Integration of amperometric sensors for microchip capillary electrophoresis application

    Energy Technology Data Exchange (ETDEWEB)

    Dicorato, F; Moore, E [Life Sciences Interface Group, Tyndall National Institute, Lee Maltings, Dyke Parade, Cork (Ireland); Glennon, J, E-mail: eric.moore@tyndall.ie [Chemistry Department, University College Cork, College Road, Cork (Ireland)

    2011-08-17

    Capillary electrophoresis is a technique for the separation and analysis of chemical compounds. Techniques adopted from the microchip technology knowledge have led to recent developments of electrophoresis system with integration on microchip. Microchip Capillary Electrophoresis ({mu}CE) systems offer a series of advantages as easy integration for Lab-on-a-chip applications, high performance, portability, speed, minimal solvent and sample requirements. A new technological challenge aims at the development of an economic modular microchip capillary electrophoresis systems using separable and independent units concerning the sensor. In this project we worked on the development of an interchangeable amperometric sensor in order to provide a solution to such electrode passivation and facilitating the use of tailored sensors for specific analyte detection besides. Fluidic chips have been machined from cyclic olefin polymer pallets (Zeonor) using a micro-injection molding machine.

  16. Ceramic protective coatings applied by sol-gel or electrophoresis

    International Nuclear Information System (INIS)

    Stoch, A.

    1993-01-01

    Sol-gel and electrophoresis are the complementary techniques which may be used for obtaining the ceramic coatings. The composition of such a coatings depends on the composition of electrophoresis bath or sol solution. Thermal treatment is used for densifying the coating and promoting the adherence of coating to the substrate. In presented work silica, silica-alumina or alumina coatings are applied by sol-gel dip coating procedure on steel, aluminium or ceramic substrates. Electrophoresis is employed for obtaining zirconia, alumina or hydroxyapatite coatings on stainless steel. (author). 7 refs

  17. Grapevine tissues and phenology differentially affect soluble carbohydrates determination by capillary electrophoresis.

    Science.gov (United States)

    Moreno, Daniela; Berli, Federico; Bottini, Rubén; Piccoli, Patricia N; Silva, María F

    2017-09-01

    Soluble carbohydrates distribution depends on plant physiology and, among other important factors, determines fruit yield and quality. In plant biology, the analysis of sugars is useful for many purposes, including metabolic studies. Capillary electrophoresis (CE) proved to be a powerful green separation technique with minimal sample preparation, even in complex plant tissues, that can provide high-resolution efficiency. Matrix effect refers to alterations in the analytical response caused by components of a sample other than the analyte of interest. Thus, the assessment and reduction of the matrix factor is fundamental for metabolic studies in different matrices. The present study evaluated the source and levels of matrix effects in the determination of most abundant sugars in grapevine tissues (mature and young leaves, berries and roots) at two phenological growth stages. Sucrose was the sugar that showed the least matrix effects, while fructose was the most affected analyte. Based on plant tissues, young leaves presented the smaller matrix effects, irrespectively of the phenology. These changes may be attributed to considerable differences at chemical composition of grapevine tissues with plant development. Therefore, matrix effect should be an important concern for plant metabolomics. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  18. 2D-electrophoresis and the urine proteome map: where do we stand?

    Science.gov (United States)

    Candiano, Giovanni; Santucci, Laura; Petretto, Andrea; Bruschi, Maurizio; Dimuccio, Veronica; Urbani, Andrea; Bagnasco, Serena; Ghiggeri, Gian Marco

    2010-03-10

    The discovery of urinary biomarkers is a main topic in clinical medicine. The development of proteomics has rapidly changed the knowledge on urine protein composition and probably will modify it again. Two-dimensional electrophoresis (2D-PAGE) coupled with mass spectrometry has represented for years the technique of choice for the analysis of urine proteins and it is time to draw some conclusions. This review will focus on major methodological aspects related to urine sample collection, storage and analysis by 2D-PAGE and attempt to define an advanced normal urine protein map. Overall, 1118 spots were reproducibly found in normal urine samples but only 275 were characterized as isoforms of 82 proteins. One-hundred height spots belonging to 30 proteins were also detected in plasma and corresponded to typical plasma components. The identity of most of the proteins found in normal urine by 2D-PAGE remains to be determined, the majority being low-molecular weight proteins (urine composition. Technology advancements in concentrating procedure will improve sensitivity and give the possibility to purify proteins for mass spectrometry. Copyright (c) 2009 Elsevier B.V. All rights reserved.

  19. Electrophoresis characterisation of protein as a method to establish the entomological origin of stingless bee honeys.

    Science.gov (United States)

    Ramón-Sierra, Jesús Manuel; Ruiz-Ruiz, Jorge Carlos; de la Luz Ortiz-Vázquez, Elizabeth

    2015-09-15

    Increasing production of stingless-bee honey and the prospect of broader marker for natural and organic products indicate the need to establish parameters to determinate the entomological origin and authenticity of honey. In this research, honeys of Apis mellifera, Melipona beecheii and Trigona spp. were collected in Yucatan, Mexico. Stingless-bee honeys contained more water and less total sugars and reducing sugars. SDS-PAGE patterns show distinctive bands for each kind of honey. The SDS-PAGE pattern of A. mellifera proteins honey showed three bands with molecular weights between 10.2 and 74.8kDa, there were five proteins bands in M. beecheii honey with molecular weights between 6.1 and 97.0kDa and nine for Trigona spp. proteins between 9.3 and 86.7kDa. Conventional physicochemical parameters along with electrophoresis profiles of stingless-bee honeys proteins could be an alternative for determination of entomological origin. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Heparin/heparan sulfate analysis by covalently modified reverse polarity capillary zone electrophoresis-mass spectrometry.

    Science.gov (United States)

    Sanderson, Patience; Stickney, Morgan; Leach, Franklin E; Xia, Qiangwei; Yu, Yanlei; Zhang, Fuming; Linhardt, Robert J; Amster, I Jonathan

    2018-04-13

    Reverse polarity capillary zone electrophoresis coupled to negative ion mode mass spectrometry (CZE-MS) is shown to be an effective and sensitive tool for the analysis of glycosaminoglycan mixtures. Covalent modification of the inner wall of the separation capillary with neutral or cationic reagents produces a stable and durable surface that provides reproducible separations. By combining CZE-MS with a cation-coated capillary and a sheath flow interface, a rapid and reliable method has been developed for the analysis of sulfated oligosaccharides from dp4 to dp12. Several different mixtures have been separated and detected by mass spectrometry. The mixtures were selected to test the capability of this approach to resolve subtle differences in structure, such as sulfation position and epimeric variation of the uronic acid. The system was applied to a complex mixture of heparin/heparan sulfate oligosaccharides varying in chain length from dp3 to dp12 and more than 80 molecular compositions were identified by accurate mass measurement. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Authentication of "Cereza del Jerte" sweet cherry varieties by free zone capillary electrophoresis (FZCE).

    Science.gov (United States)

    Serradilla, Manuel J; Martín, Alberto; Aranda, Emilio; Hernández, Alejandro; Benito, María J; Lopez-Corrales, Margarita; Córdoba, María de Guía

    2008-11-15

    The purpose of this work was to develop a procedure based on protein analysis by free zone capillary electrophoresis (FZCE) that can be used as an alternative to other methods in the determination of sweet cherry varieties for the authentication of "Cereza del Jerte". Two autochthonous varieties of sweet cherry type "Picota", 'Ambrunés' and 'Pico Negro', and the foreign variety 'Sweetheart' were used in the study. Two protocols for extracting the methanol-soluble proteins were tested. On the basis of the results, direct evaporation with nitrogen of a methanol extract was included in the extraction protocol for routine analysis. This method was found to give excellent repeatability of the corrected migration time (CMT), and showed greater effectiveness in discriminating sweet cherry varieties than the SDS-PAGE technique. Three peaks found in the FZCE electropherograms were investigated as a basis for discriminating between varieties. In addition, the FZCE analysis of methanol-soluble proteins provides information about the physico-chemical parameters relevant to the sensorial quality of the sweet cherries. Copyright © 2008 Elsevier Ltd. All rights reserved.

  2. Potential of capillary electrophoresis for the profiling of propolis

    NARCIS (Netherlands)

    Hilhorst, M.J; Somsen, G.W; de Jong, G.J.

    1998-01-01

    The usefulness of capillary electrophoresis (CE) with diode array detection for the profiling of Propolis, a hive product, is investigated. Water extracts of Propolis were analyzed with both capillary zone electrophoresis (CZE) at pH 7.0 and 9.3, and micellar electrokinetic chromatography (MEKC)

  3. Serum protein fractionation using supported molecular matrix electrophoresis.

    Science.gov (United States)

    Dong, Weijie; Matsuno, Yu-ki; Kameyama, Akihiko

    2013-08-01

    Supported molecular matrix electrophoresis (SMME), in which a hydrophilic polymer such as PVA serves as a support within a porous PVDF membrane, was recently developed. This method is similar to cellulose acetate membrane electrophoresis but differs in the compatibility to glycan analysis of the separated bands. In this report, we describe the first instance of the application of SMME to human serum fractionation, and demonstrate the differences with serum fractionation by cellulose acetate membrane electrophoresis. The SMME membrane exhibited almost no EOF during electrophoresis, unlike the cellulose acetate membrane, but afforded comparative results for serum fractionation. The visualization of each fraction was achieved by conventional staining with dye such as Direct Blue-71, and objective quantification was obtained by densitometry after inducing membrane transparency with 1-nonene. Immunostaining was also achieved. Moreover, mass spectrometric analysis of both N-linked and O-linked glycans from the separated bands was demonstrated. Serum fractionation and glycan profiling of each fraction using SMME will enable novel insights into the relationships between various glycosylation profiles and disease states. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Application of zwitterionic detergent to the solubilization of Klebsiella pneumoniae outer membrane proteins for two-dimensional gel electrophoresis.

    Science.gov (United States)

    Bednarz-Misa, I; Serek, P; Dudek, B; Pawlak, A; Bugla-Płoskońska, G; Gamian, A

    2014-12-01

    Klebsiella pneumoniae is a frequent cause of nosocomial respiratory, urinary and gastrointestinal tract infections and septicemia with the multidrug-resistant K. pneumoniae being a major public health concern. Outer membrane proteins (OMPs) are important virulence factors responsible for the appropriate adaptation to the host environment. They constitute of the antigens being the first in contact with infected organism. However, K. pneumoniae strains are heavily capsulated and it is important to establish the OMPs isolation procedure prior to proteomics extensive studies. In this study we used Zwittergent Z 3-14® as a detergent to isolate the OMPs from K. pneumoniae cells and resolve them using two-dimensional electrophoresis (2-DE). As a result we identified 134 protein spots. The OMPs identified in this study are possible candidates for the development of a protein-based vaccine against K. pneumoniae infections. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Procedures for two-dimensional electrophoresis of proteins

    Energy Technology Data Exchange (ETDEWEB)

    Tollaksen, S.L.; Giometti, C.S.

    1996-10-01

    High-resolution two-dimensional gel electrophoresis (2DE) of proteins, using isoelectric focusing in the first dimension and sodium dodecyl sulfate/polyacrylamide gel electrophoresis (SDS-PAGE) in the second, was first described in 1975. In the 20 years since those publications, numerous modifications of the original method have evolved. The ISO-DALT system of 2DE is a high-throughput approach that has stood the test of time. The problem of casting many isoelectric focusing gels and SDS-PAGE slab gels (up to 20) in a reproducible manner has been solved by the use of the techniques and equipment described in this manual. The ISO-DALT system of two-dimensional gel electrophoresis originated in the late 1970s and has been modified many times to improve its high-resolution, high-throughput capabilities. This report provides the detailed procedures used with the current ISO-DALT system to prepare, run, stain, and photograph two-dimensional gels for protein analysis.

  6. Usage of Capillary Electrophoresis for screening common Hemoglobinopathies

    Directory of Open Access Journals (Sweden)

    2016-06-01

    Full Text Available Hemoglobinopathies are most common inherited disorders in the world approximately 7 percent of the worldwide population and 5-6 percent of population of Iran are carriers. For control of this inherited hemoglobin disorders need to accurate screening by more advanced and more accurate methods. This study explains features of current Iran hemoglobin disorders, nominates the accessible methods for screening them and introduces the capillary zone electrophoresis as a rapid & more accurate method. The required data were extracted of various articles and then for good explanation, current Iran hemoglobinopathies properties were showed in the tables and electropherograms of important hemoglobin disorders in Iran population were provided for help to interpretation results of blood tests by capillary zone electrophoresis method. Hemoglobin disorders are including thalassemias & hemoglobin variants Disruption in the production and malfunction of globin chains cause types of hemoglobin disorders. We cannot introduce one of clinical laboratory tests as critical and basic method for screening and distinguishing types of inherited hemoglobin disorders as alone. For distinguishing the types of them must be prepared enough information and data of the hemoglobin disorders and for more accurate analysis must be used simultaneously different methods as Gel electrophoresis, High performance liquid chromatography, Isoelectric focusing, Capillary zone electrophoresis or molecular tests. The capillary electrophoresis is an accurate and rapid method for screening types of the hemoglobin disorders. Other side this method cannot analyze all of them, so must be used biochemical, biophysical and molecular methods for confirmation the results. This review showed we can use the capillary electrophoresis and HPLC as two complementary methods for hemoglobinopathies screening. We can analyze by the methods more hemoglobin disorders and decrease more laboratory errors. Moreover

  7. Basic study for gas cleaning using discharge and electrophoresis

    International Nuclear Information System (INIS)

    Su, Zhen-Zhou; Sawada, Jun; Takashima, Kazunori; Katsura, Shinji; Mizuno, Akira

    2004-01-01

    A NO x removal method using discharge plasma and electrophoresis for exhaust control was studied. The 65-50% of NO was oxidized to NO 2 or HNO 3 by the discharge plasma with specific input energy of 45J/l. The electrophoresis was carried out to concentrate the NO 2 or HNO 3 adsorbed on the adsorbents. As a result, 80% of the adsorbed nitrate ions were found in the anode region. A combination of molecular sieve pellets of 13X and glass fiber cloth was tested for the collection of nitrate ions. The ability of simultaneous concentration of nitrate ions and sulfate ions using electrophoresis was examined

  8. Using Gel Electrophoresis To Illustrate Protein Diversity and Isoelectric Point.

    Science.gov (United States)

    Browning, Mark; Vanable, Joseph

    2002-01-01

    Demonstrates the differences in protein structures by focusing on isoelectric point with an experiment that is observable under certain pH levels in gel electrophoresis. Explains the electrophoresis procedure and reports results of the experiments. (YDS)

  9. Large abnormal peak on capillary zone electrophoresis due to contrast agent.

    Science.gov (United States)

    Wheeler, Rachel D; Zhang, Liqun; Sheldon, Joanna

    2017-01-01

    Background Some iodinated radio-contrast media absorb ultraviolet light and can therefore be detected by capillary zone electrophoresis. If seen, these peaks are typically small with 'quantifications' of below 5 g/L. Here, we describe the detection of a large peak on capillary zone electrophoresis that was due to the radio-contrast agent, Omnipaque™. Methods Serum from a patient was analysed by capillary zone electrophoresis, and the IgG, IgA, IgM and total protein concentrations were measured. The serum sample was further analysed by gel electrophoresis and immunofixation. Results Capillary zone electrophoresis results for the serum sample showed a large peak with a concentration high enough to warrant urgent investigation. However, careful interpretation alongside the serum immunoglobulin concentrations and total protein concentration showed that the abnormal peak was a pseudoparaprotein rather than a monoclonal immunoglobulin. This was confirmed by analysis with gel electrophoresis and also serum immunofixation. The patient had had a CT angiogram with the radio-contrast agent Omnipaque™; addition of Omnipaque™ to a normal serum sample gave a peak with comparable mobility to the pseudoparaprotein in the patient's serum. Conclusions Pseudoparaproteins can appear as a large band on capillary zone electrophoresis. This case highlights the importance of a laboratory process that detects significant electrophoretic abnormalities promptly and interprets them in the context of the immunoglobulin concentrations. This should avoid incorrect reporting of pseudoparaproteins which could result in the patient having unnecessary investigations.

  10. Quantitative analysis by microchip capillary electrophoresis – current limitations and problem-solving strategies

    NARCIS (Netherlands)

    Revermann, T.; Götz, S.; Künnemeyer, Jens; Karst, U.

    2008-01-01

    Obstacles and possible solutions for the application of microchip capillary electrophoresis in quantitative analysis are described and critically discussed. Differences between the phenomena occurring during conventional capillary electrophoresis and microchip-based capillary electrophoresis are

  11. Inexpensive and Safe DNA Gel Electrophoresis Using Household Materials

    Science.gov (United States)

    Ens, S.; Olson, A. B.; Dudley, C.; Ross, N. D., III; Siddiqi, A. A.; Umoh, K. M.; Schneegurt, M. A.

    2012-01-01

    Gel electrophoresis is the single most important molecular biology technique and it is central to life sciences research, but it is often too expensive for the secondary science classroom or homeschoolers. A simple safe low-cost procedure is described here that uses household materials to construct and run DNA gel electrophoresis. Plastic…

  12. Dynamic computer simulations of electrophoresis: three decades of active research.

    Science.gov (United States)

    Thormann, Wolfgang; Caslavska, Jitka; Breadmore, Michael C; Mosher, Richard A

    2009-06-01

    Dynamic models for electrophoresis are based upon model equations derived from the transport concepts in solution together with user-inputted conditions. They are able to predict theoretically the movement of ions and are as such the most versatile tool to explore the fundamentals of electrokinetic separations. Since its inception three decades ago, the state of dynamic computer simulation software and its use has progressed significantly and Electrophoresis played a pivotal role in that endeavor as a large proportion of the fundamental and application papers were published in this periodical. Software is available that simulates all basic electrophoretic systems, including moving boundary electrophoresis, zone electrophoresis, ITP, IEF and EKC, and their combinations under almost exactly the same conditions used in the laboratory. This has been employed to show the detailed mechanisms of many of the fundamental phenomena that occur in electrophoretic separations. Dynamic electrophoretic simulations are relevant for separations on any scale and instrumental format, including free-fluid preparative, gel, capillary and chip electrophoresis. This review includes a historical overview, a survey of current simulators, simulation examples and a discussion of the applications and achievements of dynamic simulation.

  13. Interaction of albumins and heparinoids investigated by affinity capillary electrophoresis and free flow electrophoresis.

    Science.gov (United States)

    Mozafari, Mona; El Deeb, Sami; Krull, Friederike; Wildgruber, Robert; Weber, Gerhard; Reiter, Christian G; Wätzig, Hermann

    2018-02-01

    A fast and precise affinity capillary electrophoresis (ACE) method has been applied to investigate the interactions between two serum albumins (HSA and BSA) and heparinoids. Furthermore, different free flow electrophoresis methods were developed to separate the species which appears owing to interaction of albumins with pentosan polysulfate sodium (PPS) under different experimental conditions. For ACE experiments, the normalized mobility ratios (∆R/R f ), which provided information about the binding strength and the overall charge of the protein-ligand complex, were used to evaluate the binding affinities. ACE experiments were performed at two different temperatures (23 and 37°C). Both BSA and HSA interact more strongly with PPS than with unfractionated and low molecular weight heparins. For PPS, the interactions can already be observed at low mg/L concentrations (3 mg/L), and saturation is already obtained at approximately 20 mg/L. Unfractionated heparin showed almost no interactions with BSA at 23°C, but weak interactions at 37°C at higher heparin concentrations. The additional signals also appeared at higher concentrations at 37°C. Nevertheless, in most cases the binding data were similar at both temperatures. Furthermore, HSA showed a characteristic splitting in two peaks especially after interacting with PPS, which is probably attributable to the formation of two species or conformational change of HSA after interacting with PPS. The free flow electrophoresis methods have confirmed and completed the ACE experiments. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Sample Stacking in capillary zone electrophoresis : Principles, advantages and limitations

    NARCIS (Netherlands)

    Beckers, J.L.; Bocek, P.

    2000-01-01

    The principles of stacking procedures are described and their properties are discussed, including the fundamentals of the behavior of zone boundaries and the consequences of the self-correcting properties of boundaries in moving boundary electrophoresis, isotachophoresis, and zone electrophoresis.

  15. Continuous Fractionation of a two-component mixture by zone electrophoresis

    NARCIS (Netherlands)

    Zalewski, D.R.; Gardeniers, Johannes G.E.

    2009-01-01

    Synchronized continuous-flow zone electrophoresis is a recently demonstrated tool for performing electrophoretic fractionation of a complex sample. The method resembles free flow electrophoresis, but unlike in that technique, no mechanical fluid pumping is required. Instead, fast electrokinetic flow

  16. Modifications of alkaline microgel electrophoresis for sensitive detection of DNA damage

    International Nuclear Information System (INIS)

    Singh, N.P.; Stephens, R.E.; Schneider, E.L.

    1994-01-01

    The alkaline microgel electrophoresis technique was modified to achieve a substantial increase in sensitivity for the detection of radiation-induced DNA damage in human lymphocytes. This increased sensitivity was achieved through: (1) the addition of free radical scavengers to the electrophoresis solution to reduce DNA damage generated during alkaline unwinding and electrophoresis; (2) the modification of the electrophoresis unit to achieve a more uniform electric field; (3) the use of YOYO-1, a DNA dye, producing fluorescence 500-fold more intense than ethidium bromide; and (4) the introduction of an image analysis system for the quantitation of DNA migration. In human lymphocytes, these modifications have resulted in an increased sensitivity of several fold, allowing the detection of DNA damage in the range of 50 mGy. (author)

  17. Application of preparative disk gel electrophoresis for antigen purification from inclusion bodies.

    Science.gov (United States)

    Okegawa, Yuki; Koshino, Masanori; Okushima, Teruya; Motohashi, Ken

    2016-02-01

    Specific antibodies are a reliable tool to examine protein expression patterns and to determine the protein localizations within cells. Generally, recombinant proteins are used as antigens for specific antibody production. However, recombinant proteins from mammals and plants are often overexpressed as insoluble inclusion bodies in Escherichia coli. Solubilization of these inclusion bodies is desirable because soluble antigens are more suitable for injection into animals to be immunized. Furthermore, highly purified proteins are also required for specific antibody production. Plastidic acetyl-CoA carboxylase (ACCase: EC 6.4.1.2) from Arabidopsis thaliana, which catalyzes the formation of malonyl-CoA from acetyl-CoA in chloroplasts, formed inclusion bodies when the recombinant protein was overexpressed in E. coli. To obtain the purified protein to use as an antigen, we applied preparative disk gel electrophoresis for protein purification from inclusion bodies. This method is suitable for antigen preparation from inclusion bodies because the purified protein is recovered as a soluble fraction in electrode running buffer containing 0.1% sodium dodecyl sulfate that can be directly injected into immune animals, and it can be used for large-scale antigen preparation (several tens of milligrams). Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Usage of capillary electrophoresis for common hemoglobinopathies screening

    Directory of Open Access Journals (Sweden)

    Alireza Ebrahimi

    2016-06-01

    Full Text Available Hemoglobinopathies are most common inherited disorders in the world; approximately 7 percent of the worldwide population and 5-6 percent of population of Iran are carriers. The hemoglobin disorders inherit as autosomal recessive and are very common in the Mediterranean area and much of the Asia and Africa. The control of this inherited disorders need to genetic counseling and accurate screening by more advanced and more accurate methods. This study explains features of current Iran hemoglobin disorders, nominates the accessible methods for screening them and introduces the capillary zone electrophoresis as a rapid and more accurate method. The required data were extracted of various articles and then for good explanation, current Iran hemoglobinopathies properties were showed in the tables and electropherograms of important hemoglobin disorders in Iran population were provided for help to interpretation results of blood tests by capillary zone electrophoresis method. Hemoglobin disorders are including thalassemias and hemoglobin variants; Disruption in the production and malfunction of globin chains cause types of hemoglobin disorders. We cannot introduce one of clinical laboratory tests as critical and basic method for screening and distinguishing types of inherited hemoglobin disorders as alone. For distinguishing the types of them must be prepared enough information and data of the hemoglobin disorders and for more accurate analysis must be used simultaneously different methods as gel electrophoresis, high performance liquid chromatography, isoelectric focusing, capillary zone electrophoresis or molecular tests. The capillary electrophoresis is an accurate and rapid method for screening types of the hemoglobin disorders. Other side this method cannot analyze all of them, so must be used biochemical, biophysical and molecular methods for confirmation the results. This review showed we can use the capillary electrophoresis and HPLC as two

  19. Simultaneous Detection of 13 Key Bacterial Respiratory Pathogens by Combination of Multiplex PCR and Capillary Electrophoresis.

    Science.gov (United States)

    Jiang, Lu Xi; Ren, Hong Yu; Zhou, Hai Jian; Zhao, Si Hong; Hou, Bo Yan; Yan, Jian Ping; Qin, Tian; Chen, Yu

    2017-08-01

    Lower respiratory tract infections continue to pose a significant threat to human health. It is important to accurately and rapidly detect respiratory bacteria. To compensate for the limits of current respiratory bacteria detection methods, we developed a combination of multiplex polymerase chain reaction (PCR) and capillary electrophoresis (MPCE) assay to detect thirteen bacterial pathogens responsible for lower respiratory tract infections, including Streptococcus pneumoniae, Haemophilus influenzae, Moraxella catarrhalis, Pseudomonas aeruginosa, Klebsiella pneumoniae, Escherichia coli, Staphylococcus aureus, Mycoplasma pneumoniae, Legionella spp., Bordetella pertussis, Mycobacterium tuberculosis complex, Corynebacterium diphtheriae, and Streptococcus pyogenes. Three multiplex PCR reactions were built, and the products were analyzed by capillary electrophoresis using the high-throughput DNA analyzer. The specificity of the MPCE assay was examined and the detection limit was evaluated using DNA samples from each bacterial strain and the simulative samples of each strain. This assay was further evaluated using 152 clinical specimens and compared with real-time PCR reactions. For this assay, three nested-multiplex-PCRs were used to detect these clinical specimens. The detection limits of the MPCE assay for the 13 pathogens were very low and ranged from 10-7 to 10-2 ng/μL. Furthermore, analysis of the 152 clinical specimens yielded a specificity ranging from 96.5%-100.0%, and a sensitivity of 100.0% for the 13 pathogens. This study revealed that the MPCE assay is a rapid, reliable, and high-throughput method with high specificity and sensitivity. This assay has great potential in the molecular epidemiological survey of respiratory pathogens. Copyright © 2017 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.

  20. Developments in coupled solid-phase extraction-capillary electrophoresis 2013-2015.

    Science.gov (United States)

    Ramautar, Rawi; Somsen, Govert W; de Jong, Gerhardus J

    2016-01-01

    An overview of the design and application of coupled solid-phase extraction-capillary electrophoresis (SPE-CE) systems reported in the literature between July 2013 and June 2015 is provided in this paper. The present article is a continuation of our previous review papers on this topic which covered the time period 2000-2013 (Electrophoresis 2008, 29, 108-128; Electrophoresis 2010, 31, 44-54; Electrophoresis 2012, 33, 243-250; Electrophoresis 2014, 35, 128-137). The use of in-line and on-line SPE-CE approaches is treated and outlined in this review. Recent advancements, such as, for example, the use of aptamers as affinity material for in-line SPE-CE, the use of a bead string design for in-line fritless SPE-CE, and new interfacing techniques for the on-line coupling of SPE to CE, are outlined. Selected examples demonstrate the applicability of the coupled SPE-CE systems for biomedical, pharmaceutical, environmental, and food studies. A complete overview of the recent SPE-CE studies is given in table format, providing information on sample type, SPE sorbent, coupling mode, detection mode, and LOD. Finally, some general conclusions and perspectives are provided. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Microfluidic chip-capillary electrophoresis devices

    CERN Document Server

    Fung, Ying Sing; Du, Fuying; Guo, Wenpeng; Ma, Tongmei; Nie, Zhou; Sun, Hui; Wu, Ruige; Zhao, Wenfeng

    2015-01-01

    Capillary electrophoresis (CE) and microfluidic chip (MC) devices are relatively mature technologies, but this book demonstrates how they can be integrated into a single, revolutionary device that can provide on-site analysis of samples when laboratory services are unavailable. By introducing the combination of CE and MC technology, Microfluidic Chip-Capillary Electrophoresis Devices broadens the scope of chemical analysis, particularly in the biomedical, food, and environmental sciences. The book gives an overview of the development of MC and CE technology as well as technology that now allows for the fabrication of MC-CE devices. It describes the operating principles that make integration possible and illustrates some achievements already made by the application of MC-CE devices in hospitals, clinics, food safety, and environmental research. The authors envision further applications for private and public use once the proof-of-concept stage has been passed and obstacles to increased commercialization are ad...

  2. Capillary array electrophoresis using laser-excited confocal fluorescence detection

    Energy Technology Data Exchange (ETDEWEB)

    Huang, X.C.; Quesada, M.A.; Mathies, R.A. [Univ. of California, Berkeley, CA (United States)

    1992-04-15

    Capillary electrophoresis (CE) has found widespread application in analytical and biomedical research, and the scope and sophistication of CE is still rapidly advancing. Gel-filled capillaries have been employed for the rapid separation and analysis of synthetic polynucleotides, DNA sequencing fragments, and DNA restriction fragments. Open-tube capillary electrophoresis has attained subattomole detection levels in amino acid separations 14 and proven its utility for the separation of proteins, viruses, and bacteria. Separation of the optical isomers of dansyl amino acids has also been successfully demonstrated. Micellar electrokinetic capillary chromatography, isoelectric focusing, and on-column derivatization can all be performed on CE columns, demonstrating the utility of capillary electrophoresis as an analytical and micropreparative tool. 29 refs., 6 figs., 1 tab.

  3. Peak capacity and peak capacity per unit time in capillary and microchip zone electrophoresis.

    Science.gov (United States)

    Foley, Joe P; Blackney, Donna M; Ennis, Erin J

    2017-11-10

    peak capacity per unit time is a simple function of the upper bound, but its direct application is limited to samples with analytes whose electrophoretic mobilities can be varied independently of electroosmotic flow. For samples containing both co- and counter-electroosmotic ions whose electrophoretic mobilities cannot be easily manipulated, comparable levels of peak capacity and peak capacity per unit time for all ions can be obtained by adjusting the EOF to devote the same amount of time to the separation of each class of ions; this corresponds to μ r,Z =-0.5. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Field-portable Capillary Electrophoresis Instrument with Conductivity Detection

    International Nuclear Information System (INIS)

    Zhang, H F; Liu, X W; Wang, W; Wang, X L; Tian, L

    2006-01-01

    In this paper a novel capillary electrophoresis chip (CEC) is presented with integrated platinum electrodes and simplified conductivity detector. CEC is fabricated by the method of mechanical modification with probe on organic glass. Capillary electrophoresis chip can rapidly completed ion separation by simulation of concentration distribution and zone-broadening. Detection circuit is simple which can detect pA order current. This system has those advantages such as small volume, low power consumption and linearity, and well suit for field analysis

  5. Western blotting using capillary electrophoresis.

    Science.gov (United States)

    Anderson, Gwendolyn J; M Cipolla, Cynthia; Kennedy, Robert T

    2011-02-15

    A microscale Western blotting system based on separating sodium-dodecyl sulfate protein complexes by capillary gel electrophoresis followed by deposition onto a blotting membrane for immunoassay is described. In the system, the separation capillary is grounded through a sheath capillary to a mobile X-Y translation stage which moves a blotting membrane past the capillary outlet for protein deposition. The blotting membrane is moistened with a methanol and buffer mixture to facilitate protein adsorption. Although discrete protein zones could be detected, bands were broadened by ∼1.7-fold by transfer to membrane. A complete Western blot for lysozyme was completed in about one hour with 50 pg mass detection limit from low microgram per milliliter samples. These results demonstrate substantial reduction in time requirements and improvement in mass sensitivity compared to conventional Western blots. Western blotting using capillary electrophoresis shows promise to analyze low volume samples with reduced reagents and time, while retaining the information content of a typical Western blot.

  6. Magneto-paper electrophoresis in the separation of inorganic ions

    International Nuclear Information System (INIS)

    Mukherjee, H.G.; Datta, S.K.

    1983-01-01

    A comparative study of the separation of lanthanide ions by paper electrophoresis and magneto-paper electrophoresis is reported. The separation of La(III)-Gd(III), La(III)-Dy(III), Lu(III)-Gd(III), Lu(III)-Ho(III) etc. was achieved by magneto paper electrophoresis using 0.1M KCl as carrier electrolyte. Separation of different oxidation states of the same element like Cu(I)-Cu(II), Ce(III)-Ce(IV), Mn(CN) 6 3 - -Mn(CN) 6 4 - , Co(C 2 O 4 ) 2 2 - -Co(C 2 O 4 ) 3 3 - , V(CN) 6 3 - -VO(CN) 5 3 - , W(CN) 8 4 - -W(CN) 8 3 - and Ru(CN) 6 3 - Ru(CN) 6 4 - was also achieved by magneto paper electrophoretic technique using different carrier electrolytes. (Author)

  7. The gel electrophoresis markup language (GelML) from the Proteomics Standards Initiative.

    Science.gov (United States)

    Gibson, Frank; Hoogland, Christine; Martinez-Bartolomé, Salvador; Medina-Aunon, J Alberto; Albar, Juan Pablo; Babnigg, Gyorgy; Wipat, Anil; Hermjakob, Henning; Almeida, Jonas S; Stanislaus, Romesh; Paton, Norman W; Jones, Andrew R

    2010-09-01

    The Human Proteome Organisation's Proteomics Standards Initiative has developed the GelML (gel electrophoresis markup language) data exchange format for representing gel electrophoresis experiments performed in proteomics investigations. The format closely follows the reporting guidelines for gel electrophoresis, which are part of the Minimum Information About a Proteomics Experiment (MIAPE) set of modules. GelML supports the capture of metadata (such as experimental protocols) and data (such as gel images) resulting from gel electrophoresis so that laboratories can be compliant with the MIAPE Gel Electrophoresis guidelines, while allowing such data sets to be exchanged or downloaded from public repositories. The format is sufficiently flexible to capture data from a broad range of experimental processes, and complements other PSI formats for MS data and the results of protein and peptide identifications to capture entire gel-based proteome workflows. GelML has resulted from the open standardisation process of PSI consisting of both public consultation and anonymous review of the specifications.

  8. Undergraduate physics laboratory: Electrophoresis in chromatography paper

    Science.gov (United States)

    Hyde, Alexander; Batishchev, Oleg

    2015-12-01

    An experiment studying the physical principles of electrophoresis in liquids was developed for an undergraduate laboratory. We have improved upon the standard agarose gel electrophoresis experimental regime with a straightforward and cost-effective procedure, in which drops of widely available black food coloring were separated by electric field into their dye components on strips of chromatography paper soaked in a baking soda/water solution. Terminal velocities of seven student-safe dyes were measured as a function of the electric potential applied along the strips. The molecular mobility was introduced and calculated by analyzing data for a single dye. Sources of systematic and random errors were investigated.

  9. Speciation and solubility of neptunium in underground environments by paper electrophoresis

    International Nuclear Information System (INIS)

    Nagasaki, S.; Tanaka, Satoru; Takahashi, Yoichi

    1988-01-01

    Speciation and solubility of neptunium were studied using paper electrophoresis, ion exchange and ultrafiltration. Among these methods, the paper electrophoresis was found to be suitable for measuring speciation and solubility of neptunium of low concentration, if chemical species had opposite charge to each other or dissolved species had a charge. Using paper electrophoresis, hydrolysis constants of NpO 2 OH 0 and NpO 2 - (OH) 2 - and solubility product of NpO 2 were obtained and ionic-strength dependence of speciation was observed. (author) 9 refs.; 3 figs.; 2 tabs

  10. Determination of carbohydrates in honey and milk by capillary electrophoresis in combination with graphene-cobalt microsphere hybrid paste electrodes.

    Science.gov (United States)

    Liang, Peipei; Sun, Motao; He, Peimin; Zhang, Luyan; Chen, Gang

    2016-01-01

    A graphene-cobalt microsphere (CoMS) hybrid paste electrode was developed for the determination of carbohydrates in honey and milk in combination with capillary electrophoresis (CE). The performance of the electrodes was demonstrated by detecting mannitol, sucrose, lactose, glucose, and fructose after CE separation. The five analytes were well separated within 9 min in a 40 cm long capillary at a separation voltage of 12 kV. The electrodes exhibited pronounced electrocatalytic activity, lower detection potentials, enhanced signal-to-noise characteristics, and higher reproducibility. The relation between peak current and analyte concentration was linear over about three orders of magnitude. The proposed method had been employed to determine lactose in bovine milk and glucose and fructose in honey with satisfactory results. Because only electroactive substances in the samples could be detected on the paste electrode, the electropherograms of both food samples were simplified to some extent. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Instrumental development of novel detection and separation methods for capillary electrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Garner, Tommy [Iowa State Univ., Ames, IA (United States)

    1993-07-01

    After a general introduction, this thesis is divided into 3 parts: indirect fluorescence detection of sugars separated by capillary zone electrophoresis with visible laser excitation, absorption detection in capillary electrophoresis by fluorescence energy transfer, and increased selectivity for electrochromatography by dynamic ion exchange.

  12. Ultrasonic microdialysis coupled with capillary electrophoresis electrochemiluminescence study the interaction between trimetazidine dihydrochloride and human serum albumin.

    Science.gov (United States)

    Sun, Shuangjiao; Long, Chanjuan; Tao, Chunyao; Meng, Sa; Deng, Biyang

    2014-12-03

    The paper describes a homemade ultrasonic microdialysis device coupled with capillary electrophoresis electrochemiluminescence (CE-ECL) for studying the interaction between human serum albumin (HSA) and trimetazidine dihydrochloride (TMZ). The time required for equilibrium by ultrasonic microdialysis was 45min, which was far less than that by traditional dialysis (240min). It took 80min to achieve the required combination equilibrium by normal incubation and only 20min by ultrasonic. Compared with traditional dialysis, the use of ultrasonic microdialysis simplified experimental procedures, shortened experimental time and saved consumption of sample. A simple, sensitive and selective determination of TMZ was developed using CE-ECL and the parameters that affected ECL intensity were optimized. Under the optimized conditions, the linear range of TMZ was from 0.075 to 80μmol/L (r(2)=0.9974). The detection limit was 26nmol/L with RSD of 2.8%. The number of binding sites and binding constant were 1.54 and 15.17L/mol, respectively. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Versatile electrophoresis-based self-test platform.

    Science.gov (United States)

    Guijt, Rosanne M

    2015-03-01

    Lab on a Chip technology offers the possibility to extract chemical information from a complex sample in a simple, automated way without the need for a laboratory setting. In the health care sector, this chemical information could be used as a diagnostic tool for example to inform dosing. In this issue, the research underpinning a family of electrophoresis-based point-of-care devices for self-testing of ionic analytes in various sample matrices is described [Electrophoresis 2015, 36, 712-721.]. Hardware, software, and methodological chances made to improve the overall analytical performance in terms of accuracy, precision, detection limit, and reliability are discussed. In addition to the main focus of lithium monitoring, new applications including the use of the platform for veterinary purposes, sodium, and for creatinine measurements are included. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Simultaneous separation and determination of four uncaria alkaloids by capillary electrophoresis using dual cyclodextrin system.

    Science.gov (United States)

    Li, Lou; Xu, Liying; Chen, Meng; Zhang, Guangbin; Zhang, Hongfen; Chen, Anjia

    2017-07-15

    The purpose of this study was to develop a simple, quick and precise capillary zone electrophoresis method (CZE) for the separation and determination of uncaria alkaloids using dual cyclodextrins as additives for the separation. The four analytes were baseline separated within 15min at the applied voltage of 15kV with a running buffer (pH 5.7) consisting of 40.0mM phosphate buffer, 161.7mM 2-hydroxypropyl-β-cyclodextrin (HP-β-CD) and 2.21mM mono-(6-ethylenediamine-6-deoxy)-β-cyclodextrin (ED-β-CD). Under the optimum conditions, a good linearity was achieved with correlation coefficients from 0.9989 to 0.9992. The detection limits and the quantitation limits ranged from 0.63 to 0.98μg/mL and from 2.08 to 3.28μg/mL, respectively. Excellent accuracy and precision were obtained. Recoveries of the analytes varied from 97.1 to 103.2%. This method was suitable for the quantitative determination of these alkaloids in the stem with hook of Uncaria rhynchophylla and the formulations of Uncaria rhynchophylla. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Agarose gel electrophoresis for the separation of DNA fragments.

    Science.gov (United States)

    Lee, Pei Yun; Costumbrado, John; Hsu, Chih-Yuan; Kim, Yong Hoon

    2012-04-20

    Agarose gel electrophoresis is the most effective way of separating DNA fragments of varying sizes ranging from 100 bp to 25 kb(1). Agarose is isolated from the seaweed genera Gelidium and Gracilaria, and consists of repeated agarobiose (L- and D-galactose) subunits(2). During gelation, agarose polymers associate non-covalently and form a network of bundles whose pore sizes determine a gel's molecular sieving properties. The use of agarose gel electrophoresis revolutionized the separation of DNA. Prior to the adoption of agarose gels, DNA was primarily separated using sucrose density gradient centrifugation, which only provided an approximation of size. To separate DNA using agarose gel electrophoresis, the DNA is loaded into pre-cast wells in the gel and a current applied. The phosphate backbone of the DNA (and RNA) molecule is negatively charged, therefore when placed in an electric field, DNA fragments will migrate to the positively charged anode. Because DNA has a uniform mass/charge ratio, DNA molecules are separated by size within an agarose gel in a pattern such that the distance traveled is inversely proportional to the log of its molecular weight(3). The leading model for DNA movement through an agarose gel is "biased reptation", whereby the leading edge moves forward and pulls the rest of the molecule along(4). The rate of migration of a DNA molecule through a gel is determined by the following: 1) size of DNA molecule; 2) agarose concentration; 3) DNA conformation(5); 4) voltage applied, 5) presence of ethidium bromide, 6) type of agarose and 7) electrophoresis buffer. After separation, the DNA molecules can be visualized under uv light after staining with an appropriate dye. By following this protocol, students should be able to: Understand the mechanism by which DNA fragments are separated within a gel matrix Understand how conformation of the DNA molecule will determine its mobility through a gel matrix Identify an agarose solution of appropriate

  16. Joachim kohn (1912-1987) and the origin of cellulose acetate electrophoresis.

    Science.gov (United States)

    Rocco, Richard M

    2005-10-01

    The year 2006 marks the 50th anniversary of the discovery of cellulose acetate (CA) electrophoresis by Joachim Kohn, a pathologist at Queen Mary's Hospital in Roehampton, London. During a career in pathology that began in 1950 and spanned 37 years, Kohn published more than 50 papers in clinical laboratory medicine. He was the first to report the use of CA microbiology filters as solid supports for zone electrophoresis and the separation of hemoglobin phenotypes on CA membranes. Kohn also invented a new electrophoresis chamber and an 8-position stamp applicator especially for use with CA membranes. Beginning in 1957, Kohn pioneered the development of CA techniques for immunoelectrophoresis, counter immunoelectrophoresis, radial immunodiffusion, protein blotting, and immunofixation. He also designed a transport dressing for burn patients and was the first person to describe the use of an enzyme-based dipstick for measuring fingerstick blood glucose concentrations. This short review highlights Kohn's discovery of CA electrophoresis and his contributions to the development of this procedure.

  17. Concentration polarization in nanochannel DNA electrophoresis

    NARCIS (Netherlands)

    Dubsky, P.; Das, Siddhartha; van den Berg, Albert; Eijkel, Jan C.T.

    2011-01-01

    We demonstrate that the large field electrophoresis of a single DNA molecule in nanofluidic systems is accompanied by concentration polarization. We illustrate this phenomena by utilizing our electrophoretic simulation tool SIMUL. First we in-vestigate a simple system with univalent strong

  18. Applications of on-line weak affinity interactions in free solution capillary electrophoresis

    DEFF Research Database (Denmark)

    Heegaard, Niels H H; Nissen, Mogens H; Chen, David D Y

    2002-01-01

    The impressive selectivity offered by capillary electrophoresis can in some cases be further increased when ligands or additives that engage in weak affinity interactions with one or more of the separated analytes are added to the electrophoresis buffer. This on-line affinity capillary...... electrophoresis approach is feasible when the migration of complexed molecules is different from the migration of free molecules and when separation conditions are nondenaturing. In this review, we focus on applying weak interactions as tools to enhance the separation of closely related molecules, e.g., drug...... enantiomers and on using capillary electrophoresis to characterize such interactions quantitatively. We describe the equations for binding isotherms, illustrate how selectivity can be manipulated by varying the additive concentrations, and show how the methods may be used to estimate binding constants. On...

  19. Seed Biology of Medicinal Plants (IX) : The Relationship of Corydalis Species Derived by Gel Electrophoresis

    OpenAIRE

    米田, 該典; 加賀, 順二; 那須, 正夫; KAISUKE, YONEDA; JUNJI, KAGA; MASAO, NASU; 大阪大学薬学部; 大阪大学薬学部; 大阪大学薬学部; Faculty of Pharmaceutical Sciences, Osaka University; Faculty of Pharmaceutical Sciences, Osaka University; Faculty of Pharmaceutical Sciences, Osaka University

    1987-01-01

    The saline soluble protein fraction of seeds of the Corydalis species (Papaveraceae) in Japan was examined by polyacrylamide gel electrophoresis and SDS-polyacrylamide gel electrophoresis. The esterase zymogram suggested that C. pallida, C. pallida var. tenuis, C. heterocarpa var. japonica and C. speciosa, having yellow flowers and no tuber, are closely related to each other. Electrophoresis and SDS-electrophoresis patterns also coincided with the result of the esterase zymogram. They also su...

  20. A Study on Major Components of Bee Venom Using Electrophoresis

    Directory of Open Access Journals (Sweden)

    Lee, Jin-Seon

    2000-12-01

    Full Text Available This study was designed to study on major components of various Bee Venom(Bee Venom by electrical stimulation in Korea; K-BV I, Bee Venom by Microwave stimulation in Korea; K -BV II, 0.5rng/ml, Fu Yu Pharmaceutical Factory, China; C-BV, 1mg /ml, Monmouth Pain Institute, Inc., U.S.A.; A-BV using Electrophoresis. The results were summarized as follows: 1. In 1:4000 Bee Venom solution rate, the band was not displayed distinctly usmg Electrophoresis. But in 1: 1000, the band showed clearly. 2. The results of Electrophoresis at solution rate 1:1000, K-BV I and K-BVII showed similar band. 3. The molecular weight of Phospholipase A2 was known as 19,000 but its band was seen at 17,000 in Electrophoresis. 4. Protein concentration of Bee Venom by Lowry method was different at solution rate 1:4000 ; C-BV was 250μg/ml, K-BV I was 190μg/ml, K-BV Ⅱ was 160μg/ml and C-BV was 45μg/ml. 5. Electrophoresis method was unuseful for analysis of Bee Venom when solution rate is above 1:4000 but Protein concentration of Bee Venom by Lowry method was possible. These data from the study can be applied to establish the standard measurement of Bee Venom and prevent pure bee venom from mixing of another components. I think it is desirable to study more about safety of Bee Venom as time goes by.

  1. Tracing outbreaks of Streptococcus equi infection (strangles) in horses using sequence variation in the seM gene and pulsed-field gel electrophoresis.

    Science.gov (United States)

    Lindahl, Susanne; Söderlund, Robert; Frosth, Sara; Pringle, John; Båverud, Viveca; Aspán, Anna

    2011-11-21

    Strangles is a serious respiratory disease in horses caused by Streptococcus equi subspecies equi (S. equi). Transmission of the disease occurs by direct contact with an infected horse or contaminated equipment. Genetically, S. equi strains are highly homogenous and differentiation of strains has proven difficult. However, the S. equi M-protein SeM contains a variable N-terminal region and has been proposed as a target gene to distinguish between different strains of S. equi and determine the source of an outbreak. In this study, strains of S. equi (n=60) from 32 strangles outbreaks in Sweden during 1998-2003 and 2008-2009 were genetically characterized by sequencing the SeM protein gene (seM), and by pulsed-field gel electrophoresis (PFGE). Swedish strains belonged to 10 different seM types, of which five have not previously been described. Most were identical or highly similar to allele types from strangles outbreaks in the UK. Outbreaks in 2008/2009 sharing the same seM type were associated by geographic location and/or type of usage of the horses (racing stables). Sequencing of the seM gene generally agreed with pulsed-field gel electrophoresis profiles. Our data suggest that seM sequencing as a epidemiological tool is supported by the agreement between seM and PFGE and that sequencing of the SeM protein gene is more sensitive than PFGE in discriminating strains of S. equi. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. Old but Still Relevant: High Resolution Electrophoresis and Immunofixation in Multiple Myeloma.

    Science.gov (United States)

    Misra, Aroonima; Mishra, Jyoti; Chandramohan, Jagan; Sharma, Atul; Raina, Vinod; Kumar, Rajive; Soni, Sushant; Chopra, Anita

    2016-03-01

    High resolution electrophoresis (HRE) and immunofixation (IFX) of serum and urine are integral to the diagnostic work-up of multiple myeloma. Unusual electrophoresis patterns are common and may be misinterpreted. Though primarily the responsibility of the hematopathologist, clinicians who are responsible for managing myelomas may benefit from knowledge of these. In this review article we intend to discuss the patterns and importance of electrophoresis in present day scenario. Patterns of HRE and IFX seen in our laboratory over the past 15 years were studied. Monoclonal proteins are seen on HRE as sharply defined bands, sometimes two, lying from γ- to α-globulin regions on a background of normal, increased or decreased polyclonal γ-globulins, showing HRE to be a rapid and dependable method of detecting M-protein in serum or urine. Immunofixation complements HRE and due to its greater sensitivity, is able to pick up small or light chain bands, not apparent on electrophoresis, including biclonal disease even when electrophoresis shows only one M-band. Special features liable to misinterpretation are discussed. Familiarity with the interpretation of the varied patterns seen in health and disease is essential for providing dependable laboratory support in the management of multiple myeloma.

  3. Electrophoresis for the analysis of heparin purity and quality.

    Science.gov (United States)

    Volpi, Nicola; Maccari, Francesca; Suwan, Jiraporn; Linhardt, Robert J

    2012-06-01

    The adulteration of raw heparin with oversulfated chondroitin sulfate (OSCS) in 2007-2008 produced a global crisis resulting in extensive revisions to the pharmacopeia monographs and prompting the FDA to recommend the development of additional methods for the analysis of heparin purity. As a consequence, a wide variety of innovative analytical approaches have been developed for the quality assurance and purity of unfractionated and low-molecular-weight heparins. This review discusses recent developments in electrophoresis techniques available for the sensitive separation, detection, and partial structural characterization of heparin contaminants. In particular, this review summarizes recent publications on heparin quality and related impurity analysis using electrophoretic separations such as capillary electrophoresis (CE) of intact polysaccharides and hexosamines derived from their acidic hydrolysis, and polyacrylamide gel electrophoresis (PAGE) for the separation of heparin samples without and in the presence of its relatively specific depolymerization process with nitrous acid treatment. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Rapid and sensitive quantification of C3- and C6-phosphoesters in starch by fluorescence-assisted capillary electrophoresis.

    Science.gov (United States)

    Verbeke, Jeremy; Penverne, Christophe; D'Hulst, Christophe; Rolando, Christian; Szydlowski, Nicolas

    2016-11-05

    Phosphate groups are naturally present in starch at C3- or C6-position of the glucose residues and impact the structure of starch granules. Their precise quantification is necessary for understanding starch physicochemical properties and metabolism. Nevertheless, reliable quantification of Glc-3-P remains laborious and time consuming. Here we describe a capillary electrophoresis method for simultaneous measurement of both Glc-6-P and Glc-3-P after acid hydrolysis of starch. The sensitivity threshold was estimated at the fg scale, which is compatible with the analysis of less than a μg of sample. The method was validated by analyzing antisense potato lines deficient in SBEs, GWD or GBSS. We show that Glc-3-P content is altered in the latter and that these variations do not correlate with modifications in Glc-6-P content. We anticipate the method reported here to be an efficient tool for high throughput study of starch phosphorylation at both C3- and C6-position. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Phylogenetic reconstruction of South American felids defined by protein electrophoresis

    OpenAIRE

    Pecon Slattery, J.; Johnson, W. E.; Goldman, D.; O'Brien, S. J.

    1994-01-01

    Phylogenetic associations among six closely related South American felid species were defined by changes in protein-encoding gene loci. We analyzed proteins isolated from skin fibroblasts using two-dimensional electrophoresis and allozymes extracted from blood cells. Genotypes were determined for multiple individuals of ocelot, margay, tigrina, Geoffroy's cat, kodkod, and pampas cat at 548 loci resolved by two-dimensional electrophoresis and 44 allozyme loci. Phenograms were constructed using...

  6. Pressure-assisted electrokinetic injection for on-line enrichment in capillary electrophoresis-mass spectrometry: a sensitive method for measurement of ten haloacetic acids in drinking water.

    Science.gov (United States)

    Zhang, Huijuan; Zhu, Jiping; Aranda-Rodriguez, Rocio; Feng, Yong-Lai

    2011-11-07

    Haloacetic acids (HAAs) are by-products of the chlorination of drinking water containing natural organic matter and bromide. A simple and sensitive method has been developed for determination of ten HAAs in drinking water. The pressure-assisted electrokinetic injection (PAEKI), an on-line enrichment technique, was employed to introduce the sample into a capillary electrophoresis (CE)-electrospray ionization-tandem mass spectrometry system (ESI-MS/MS). HAAs were monitored in selected reaction monitoring mode. With 3 min of PAEKI time, the ten major HAAs (HAA10) in drinking water were enriched up to 20,000-fold into the capillary without compromising resolution. A simple solid phase clean-up method has been developed to eliminate the influence of ionic matrices from drinking water on PAEKI. Under conditions optimized for mass spectrometry, PAEKI and capillary electrophoresis, detection limits defined as three times ratio of signal to noise have been achieved in a range of 0.013-0.12 μg L(-1) for ten HAAs in water sample. The overall recoveries for all ten HAAs in drinking water samples were between 76 and 125%. Six HAAs including monochloro- (MCAA), dichloro- (DCAA), trichloro- (TCAA), monobromo- (MBAA), bromochloro- (BCAA), and bromodichloroacetic acids (BDCAA) were found in tap water samples collected. Crown Copyright © 2011. Published by Elsevier B.V. All rights reserved.

  7. Development of bufferless gel electrophoresis chip for easy preparation and rapid DNA separation.

    Science.gov (United States)

    Oleksandrov, Sergiy; Aman, Abdurazak; Lim, Wanyoung; Kim, Younghee; Bae, Nam Ho; Lee, Kyoung G; Lee, Seok Jae; Park, Sungsu

    2018-02-01

    This work presents a handy, fast, and compact bufferless gel electrophoresis chip (BGEC), which consists of precast agarose gel confined in a disposable plastic body with electrodes. It does not require large volumes of buffer to fill reservoirs, or the process of immersing the gel in the buffer. It withstands voltages up to 28.4 V/cm, thereby allowing DNA separation within 10 min with a similar separation capability to the standard gel electrophoresis. The results suggest that our BGEC is highly suitable for in situ gel electrophoresis in forensic, epidemiological settings and crime scenes where standard gel electrophoresis equipment cannot be brought in while quick results are needed. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Contemporary sample stacking in analytical electrophoresis

    Czech Academy of Sciences Publication Activity Database

    Šlampová, Andrea; Malá, Zdeňka; Pantůčková, Pavla; Gebauer, Petr; Boček, Petr

    2013-01-01

    Roč. 34, č. 1 (2013), s. 3-18 ISSN 0173-0835 R&D Projects: GA ČR GAP206/10/1219 Institutional support: RVO:68081715 Keywords : biological samples * stacking * trace analysis * zone electrophoresis Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.161, year: 2013

  9. Matching Two-dimensional Gel Electrophoresis' Spots

    DEFF Research Database (Denmark)

    Dos Anjos, António; AL-Tam, Faroq; Shahbazkia, Hamid Reza

    2012-01-01

    This paper describes an approach for matching Two-Dimensional Electrophoresis (2-DE) gels' spots, involving the use of image registration. The number of false positive matches produced by the proposed approach is small, when compared to academic and commercial state-of-the-art approaches. This ar...

  10. Contemporary sample stacking in analytical electrophoresis

    Czech Academy of Sciences Publication Activity Database

    Malá, Zdeňka; Šlampová, Andrea; Křivánková, Ludmila; Gebauer, Petr; Boček, Petr

    2015-01-01

    Roč. 36, č. 1 (2015), s. 15-35 ISSN 0173-0835 R&D Projects: GA ČR(CZ) GA13-05762S Institutional support: RVO:68081715 Keywords : biological samples * stacking * trace analysis * zone electrophoresis Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 2.482, year: 2015

  11. Comparison of fractional flow reserve of composite Y-grafts with saphenous vein or right internal thoracic arteries.

    Science.gov (United States)

    Glineur, David; Boodhwani, Munir; Poncelet, Alain; De Kerchove, Laurent; Etienne, Pierre Yves; Noirhomme, Philippe; Deceuninck, Paul; Michel, Xavier; El Khoury, Gebrine; Hanet, Claude

    2010-09-01

    Composite Y-grafts, using the left internal thoracic artery as the inflow, allow a more efficient use of conduits without the need to touch a diseased ascending aorta. Among other conduits, the saphenous vein graft may be an alternative to the radial artery in elderly patients. We evaluated the hemodynamic characteristics of 17 composite Y-grafts made with the left internal thoracic artery anastomosed to the left anterior descending coronary artery in all cases and with either the free right internal thoracic artery (RITA group, n = 10) or a saphenous vein graft (SVG group, n = 7) implanted proximally to the left internal thoracic artery and distally to the circumflex territory 6 months after the operation. At baseline, the pressure gradient measured with a 0.014-inch pressure wire was minimal between the aorta and the internal thoracic artery stem (2 +/- 1 mm Hg), the internal thoracic artery and left anterior descending (4 +/- 2 mm Hg), the internal thoracic artery and left circumflex (3 +/- 1 mm Hg), and the saphenous vein graft and left circumflex (2 +/- 2 mm Hg). During hyperemia induced by adenosine, the pressure gradient increased significantly to 6 +/- 2 mm Hg in the internal thoracic artery stem, 9 +/- 4 mm Hg in the internal thoracic artery and left anterior descending artery, 9 +/- 3 mm Hg in the internal thoracic artery and left circumflex, and 7 +/- 4 mm Hg in the saphenous vein graft and left circumflex. Fractional flow reserve was 0.94 +/- 0.02 in internal thoracic artery stem, 0.90 +/- 0.04 mm Hg in the internal thoracic artery and left anterior descending, 0.91 +/- 0.03 mm Hg in the internal thoracic artery and left circumflex, and 0.92 +/- 0.06 mm Hg in the saphenous vein graft and left circumflex. No difference between the two types of composite Y-grafts was observed for pressure gradients or fractional flow reserve measured in internal thoracic artery stem or in distal branches. Composite Y-grafts with saphenous vein or right internal thoracic

  12. [The sequential use of local vacuum magnetotherapy and papaverine electrophoresis with sinusoidal modulated currents in impotence].

    Science.gov (United States)

    Karpukhin, I V; Bogomol'nyĭ, V A

    1997-01-01

    105 patients with chronic nonspecific prostatitis were examined and treated with papaverin electrophoresis using sinusoidal modulated currents (SMC) and local vacuum magnetotherapy (LVMT). Papaverin SMC electrophoresis and LVMT stimulated cavernous circulation. The highest stimulation was achieved at successive use of LVMT and the electrophoresis. LVMT followed by the electrophoresis maintained good cavernous circulation for 5-6 hours after the procedure in the course of which several spontaneous erections were observed.

  13. Variations of plasma protein electrophoresis in healthy captive Green Iguanas (Iguana iguana).

    Science.gov (United States)

    Musilová, Anna; Knotková, Zora; Pinterová, Kateřina; Knotek, Zdeněk

    2015-06-01

    Serum or plasma protein electrophoresis is used as a routine test for health assessment in veterinary medicine, but there are only a limited number of studies regarding clinical use of electrophoresis in reptile species. The goals of this study were to establish reference intervals for plasma protein electrophoresis in the Green Iguana (Iguana iguana), compare values between males and females, and to identify season-related changes. Plasma samples were obtained from 21 healthy captive male and female Green Iguanas. Agarose gel electrophoresis was performed using an automated Hydrasys system. Four main protein fractions were observed: albumin, α globulins, β globulins, and γ globulins. Bisalbuminemia was observed in 4 of 21 healthy iguanas. Minimum and maximum values were reported for healthy Green Iguanas in March, June, September, and December. Seasonal changes in albumin were determined between March and December, and in γ globulins between June and September. Differences between males and females were seen in albumin concentration in September. Reference intervals of the plasma protein fractions according to electrophoresis in the Green Iguana can be affected by seasonal changes and sex of animals. It should be taken into account when clinical evaluation is performed. © 2015 American Society for Veterinary Clinical Pathology.

  14. Micro-injector for capillary electrophoresis.

    Science.gov (United States)

    Sáiz, Jorge; Koenka, Israel Joel; García-Ruiz, Carmen; Müller, Beat; Chwalek, Thomas; Hauser, Peter C

    2015-08-01

    A novel micro-injector for capillary electrophoresis for the handling of samples with volumes down to as little as 300 nL was designed and built in our laboratory for analyses in which the available volume is a limitation. The sample is placed into a small cavity located directly in front of the separation capillary, and the injection is then carried out automatically by controlled pressurization of the chamber with compressed air. The system also allows automated flushing of the injection chamber as well as of the capillary. In a trial with a capillary electrophoresis system with contactless conductivity detector, employing a capillary of 25 μm diameter, the results showed good stability of migration times and peak areas. To illustrate the technique, the fast separation of five inorganic cations (Na(+) , K(+) , NH4 (+) , Ca(2+) , and Mg(2+) ) was set up. This could be achieved in less than 3 min, with good limits of detection (10 μM) and linear ranges (between about 10 and 1000 μM). The system was demonstrated for the determination of the inorganic cations in porewater samples of a lake sediment core. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Thermostatted dual-channel portable capillary electrophoresis instrument

    Czech Academy of Sciences Publication Activity Database

    Koenka, I.J.; Küng, N.; Kubáň, Pavel; Chwalek, T.; Furrer, G.; Wehrli, B.; Müller, B.; Hauser, P.C.

    2016-01-01

    Roč. 37, 17-18 (2016), s. 2368-2375 ISSN 0173-0835 Institutional support: RVO:68081715 Keywords : portable devices * on-site measurements * capillary electrophoresis Subject RIV: CB - Analytical Chemistry , Separation Impact factor: 2.744, year: 2016

  16. Thermostatted dual-channel portable capillary electrophoresis instrument

    Czech Academy of Sciences Publication Activity Database

    Koenka, I.J.; Küng, N.; Kubáň, Pavel; Chwalek, T.; Furrer, G.; Wehrli, B.; Müller, B.; Hauser, P.C.

    2016-01-01

    Roč. 37, 17-18 (2016), s. 2368-2375 ISSN 0173-0835 Institutional support: RVO:68081715 Keywords : portable devices * on-site measurements * capillary electrophoresis Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 2.744, year: 2016

  17. Electrophoresis-base dye adsorption into titanium dioxide film for dye sensitized solar cell application

    International Nuclear Information System (INIS)

    Ratno Nuryadi; Zico Alaia Akbar Junior; Lia Aprilia

    2010-01-01

    Dye Sensitized Solar Cell (DSSC) is one of renewable energy sources which has demanded a substitute non renewable energy sources. The most important factor influencing DSSC performance is dye adsorption into semiconductor nano-porous TiO 2 particles. The purpose of this work is to study the effect of dye eosin Y adsorption on DSSC characteristics by an electrophoresis method. As result, Open Circuit Voltage (V oc ) of DSSC increases as the applied voltage of electrophoresis increases. It is also found that the eosin Y absorbance at wavelength of around 500 nm increases when the electrophoresis voltage is increased. These results indicate that electrophoresis process plays an important role in dye adsorption. (author)

  18. Automated Lab-on-a-Chip Electrophoresis System

    Science.gov (United States)

    Willis, Peter A.; Mora, Maria; Greer, Harold F.; Fisher, Anita M.; Bryant, Sherrisse

    2012-01-01

    Capillary electrophoresis is an analytical technique that can be used to detect and quantify extremely small amounts of various biological molecules. In the search for biochemical traces of life on other planets, part of this search involves an examination of amino acids, which are the building blocks of life on Earth. The most sensitive method for detecting amino acids is the use of laser induced fluorescence. However, since amino acids do not, in general, fluoresce, they first must be reacted with a fluorescent dye label prior to analysis. After this process is completed, the liquid sample then must be transported into the electrophoresis system. If the system is to be reused multiple times, samples must be added and removed each time. In typical laboratories, this process is performed manually by skilled human operators using standard laboratory equipment. This level of human intervention is not possible if this technology is to be implemented on extraterrestrial targets. Microchip capillary electrophoresis (CE) combined with laser induced fluorescence detection (LIF) was selected as an extremely sensitive method to detect amino acids and other compounds that can be tagged with a fluorescent dye. It is highly desirable to package this technology into an integrated, autonomous, in situ instrument capable of performing CE-LIF on the surface of an extraterrestrial body. However, to be fully autonomous, the CE device must be able to perform a large number of sample preparation and analysis operations without the direct intervention of a human.

  19. Sub-minute method for simultaneous determination of aspartame, cyclamate, acesulfame-K and saccharin in food and pharmaceutical samples by capillary zone electrophoresis.

    Science.gov (United States)

    Vistuba, Jacqueline Pereira; Dolzan, Maressa Danielli; Vitali, Luciano; de Oliveira, Marcone Augusto Leal; Micke, Gustavo Amadeu

    2015-05-29

    This paper reports the development of a sub-minute separation method by capillary zone electrophoresis for the determination of aspartame, cyclamate, acesulfame-K and saccharin in food products and pharmaceutical samples. Separations were performed in a fused uncoated silica capillary with UV detection at 220nm. Samples and standards were injected hydrodynamically using the short-end injection procedure. The electrophoretic system was operated under constant voltage of -30kV. The background electrolyte was composed of 45mmolL(-1) 2-amino-2-(hydroxymethyl)-1,3-propanediol and 15mmolL(-1) benzoic acid at pH 8.4. The separation time for all analytes was less than 1min. Evaluation of analytical parameters of the method showed good linearity (r(2)>0.9972), limit of detection of 3.3-6.4mgL(-1), intermediate precision better than 9.75% (peak area of sample) and recovery in the range of 91-117%. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Plasma protein electrophoresis of Trachemys scripta and Iguana iguana.

    Science.gov (United States)

    Giménez, Mercè; Saco, Yolanda; Pato, Raquel; Busquets, Alex; Martorell, Jaime M; Bassols, Anna

    2010-06-01

    Protein electrophoresis is widely applied in veterinary medicine, but is not used often in reptiles, in part because of lack of reference values. The goals of this study were to compare plasma protein profiles obtained by cellulose acetate electrophoresis (CAE) and agarose gel electrophoresis (AGE), measure precision and examine interference by sample hemolysis, and establish preliminary reference intervals for 2 reptile species. Heparinized plasma samples from healthy and diseased adult female Iguana iguana (n=40) and Trachemys scripta (n=60) were analyzed by CAE and AGE. Total protein concentration was measured by the biuret method. Electrophoresis results were compared using Bland-Altman plots and Passing-Bablok regression analysis. Precision and the effects of sample hemolysis were determined. Results from clinically healthy animals were used to determine reference intervals. Five protein fractions were identified in both species, with bisalbuminemia observed in 23/40 iguanas. High correlation was observed between the 2 methods for all fractions, with few proportional and systematic errors. Coefficients of variation were lower using AGE vs CAE and for I. iguana vs T. scripta. Two additional bands were observed in hemolyzed samples from T. scripta; 1 additional band was observed for I. iguana. Minimum and maximum values were reported for healthy I. iguana (n=14) and T. scripta (n=22). Although both methods are acceptable, the performance of AGE was slightly better than that of CAE for analysis of plasma from reptiles. Furthermore, reptile electrophoretic patterns should be interpreted based on the method used, the species analyzed, and the quality of the plasma sample.

  1. Simulation of Two Dimensional Electrophoresis and Tandem Mass Spectrometry for Teaching Proteomics

    Science.gov (United States)

    Fisher, Amanda; Sekera, Emily; Payne, Jill; Craig, Paul

    2012-01-01

    In proteomics, complex mixtures of proteins are separated (usually by chromatography or electrophoresis) and identified by mass spectrometry. We have created 2DE Tandem MS, a computer program designed for use in the biochemistry, proteomics, or bioinformatics classroom. It contains two simulations--2D electrophoresis and tandem mass spectrometry.…

  2. Characterization of asphaltenes by nonaqueous capillary electrophoresis

    NARCIS (Netherlands)

    Kok, W.T.; Tüdös, A.J.; Grutters, M.; Shepherd, A.G.

    2011-01-01

    Nonaqueous capillary electrophoresis was used for the separation and characterization of asphaltene samples from different sources. For the separation medium (background electrolyte), mixtures of tetrahydrofuran and a high-permittivity organic solvent could be used. The best results were obtained

  3. Capillary electrophoresis method with UV-detection for analysis of free amino acids concentrations in food.

    Science.gov (United States)

    Omar, Mei Musa Ali; Elbashir, Abdalla Ahmed; Schmitz, Oliver J

    2017-01-01

    Simple and inexpensive capillary electrophoresis with UV-detection method (CE-UV) was optimized and validated for determination of six amino acids namely (alanine, asparagine, glutamine, proline, serine and valine) for Sudanese food. Amino acids in the samples were derivatized with 4-chloro-7-nitro-2,1,3-benzoxadiazole (NBD-Cl) prior to CE-UV analysis. Labeling reaction conditions (100mM borate buffer at pH 8.5, labeling reaction time 60min, temperature 70°C and NBD-Cl concentration 40mM) were systematically investigated. The optimal conditions for the separation were 100mM borate buffer at pH 9.7 and detected at 475nm. The method was validated in terms of linearity, limit of detection (LOD), limit of quantification (LOQ), precision (repeatability) (RSD%) and accuracy (recovery). Good linearity was achieved for all amino acids (r(2)>0.9981) in the concentration range of 2.5-40mg/L. The LODs in the range of 0.32-0.56mg/L were obtained. Recoveries of amino acids ranging from 85% to 108%, (n=3) were obtained. The validated method was successfully applied for the determination of amino acids for Sudanese food samples. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Use of denaturing gradient gel electrophoresis to detect Actinobacteria associated with the human faecal microbiota.

    Science.gov (United States)

    Hoyles, Lesley; Clear, Jessica A; McCartney, Anne L

    2013-08-01

    With the exceptions of the bifidobacteria, propionibacteria and coriobacteria, the Actinobacteria associated with the human gastrointestinal tract have received little attention. This has been due to the seeming absence of these bacteria from most clone libraries. In addition, many of these bacteria have fastidious growth and atmospheric requirements. A recent cultivation-based study has shown that the Actinobacteria of the human gut may be more diverse than previously thought. The aim of this study was to develop a denaturing gradient gel electrophoresis (DGGE) approach for characterizing Actinobacteria present in faecal samples. Amount of DNA added to the Actinobacteria-specific PCR used to generate strong PCR products of equal intensity from faecal samples of five infants, nine adults and eight elderly adults was anti-correlated with counts of bacteria obtained using fluorescence in situ hybridization probe HGC69A. A nested PCR using Actinobacteria-specific and universal PCR-DGGE primers was used to generate profiles for the Actinobacteria. Cloning of sequences from the DGGE bands confirmed the specificity of the Actinobacteria-specific primers. In addition to members of the genus Bifidobacterium, species belonging to the genera Propionibacterium, Microbacterium, Brevibacterium, Actinomyces and Corynebacterium were found to be part of the faecal microbiota of healthy humans. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. OFFGEL electrophoresis and tandem mass spectrometry approach compared with DNA-based PCR method for authentication of meat species from raw and cooked ground meat mixtures containing cattle meat, water buffalo meat and sheep meat.

    Science.gov (United States)

    Naveena, Basappa M; Jagadeesh, Deepak S; Jagadeesh Babu, A; Madhava Rao, T; Kamuni, Veeranna; Vaithiyanathan, S; Kulkarni, Vinayak V; Rapole, Srikanth

    2017-10-15

    The present study compared the accuracy of an OFFGEL electrophoresis and tandem mass spectrometry-based proteomic approach with a DNA-based method for meat species identification from raw and cooked ground meat mixes containing cattle, water buffalo and sheep meat. The proteomic approach involved the separation of myofibrillar proteins using OFFGEL electrophoresis, SDS-PAGE and protein identification by MALDI-TOF MS. Species-specific peptides derived from myosin light chain-1 and 2 were identified for authenticating buffalo meat spiked at a minimum 0.5% level in sheep meat with high confidence. Relative quantification of buffalo meat mixed with sheep meat was done by quantitative label-free mass spectrometry using UPLC-QTOF and PLGS search engine to substantiate the confidence level of the data. In the DNA-based method, PCR amplification of mitochondrial D loop gene using species specific primers found 226bp and 126bp product amplicons for buffalo and cattle meat, respectively. The method was efficient in detecting a minimum of 0.5% and 1.0% when buffalo meat was spiked with cattle meat in raw and cooked meat mixes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Multiplexed Western Blotting Using Microchip Electrophoresis.

    Science.gov (United States)

    Jin, Shi; Furtaw, Michael D; Chen, Huaxian; Lamb, Don T; Ferguson, Stephen A; Arvin, Natalie E; Dawod, Mohamed; Kennedy, Robert T

    2016-07-05

    Western blotting is a commonly used protein assay that combines the selectivity of electrophoretic separation and immunoassay. The technique is limited by long time, manual operation with mediocre reproducibility, and large sample consumption, typically 10-20 μg per assay. Western blots are also usually used to measure only one protein per assay with an additional housekeeping protein for normalization. Measurement of multiple proteins is possible; however, it requires stripping membranes of antibody and then reprobing with a second antibody. Miniaturized alternatives to Western blot based on microfluidic or capillary electrophoresis have been developed that enable higher-throughput, automation, and greater mass sensitivity. In one approach, proteins are separated by electrophoresis on a microchip that is dragged along a polyvinylidene fluoride membrane so that as proteins exit the chip they are captured on the membrane for immunoassay. In this work, we improve this method to allow multiplexed protein detection. Multiple injections made from the same sample can be deposited in separate tracks so that each is probed with a different antibody. To further enhance multiplexing capability, the electrophoresis channel dimensions were optimized for resolution while keeping separation and blotting times to less than 8 min. Using a 15 μm deep × 50 μm wide × 8.6 cm long channel, it is possible to achieve baseline resolution of proteins that differ by 5% in molecular weight, e.g., ERK1 (44 kDa) from ERK2 (42 kDa). This resolution allows similar proteins detected by cross-reactive antibodies in a single track. We demonstrate detection of 11 proteins from 9 injections from a single Jurkat cell lysate sample consisting of 400 ng of total protein using this procedure. Thus, multiplexed Western blots are possible without cumbersome stripping and reprobing steps.

  7. Serum protein concentrations from clinically healthy horses determined by agarose gel electrophoresis.

    Science.gov (United States)

    Riond, Barbara; Wenger-Riggenbach, Bettina; Hofmann-Lehmann, Regina; Lutz, Hans

    2009-03-01

    Serum protein electrophoresis is a useful screening test in equine laboratory medicine. The method can provide valuable information about changes in the concentrations of albumin and alpha-, beta-, and gamma-globulins and thereby help characterize dysproteinemias in equine patients. Reference values for horses using agarose gel as a support medium have not been reported. The purpose of this study was to establish reference intervals for serum protein concentrations in adult horses using agarose gel electrophoresis and to assess differences between warm-blooded and heavy draught horses. In addition, the precision of electrophoresis for determining fraction percentages and the detection limit were determined. Blood samples were obtained from 126 clinically healthy horses, including 105 Thoroughbreds and 21 heavy draught horses of both sexes and ranging from 2 to 20 years of age. The total protein concentration was determined by an automated biuret method. Serum protein electrophoresis was performed using a semi-automated agarose gel electrophoresis system. Coefficients of variation (CVs) were calculated for within-run and within-assay precision. Data from warm-blooded and draught horses were compared using the Mann-Whitney U test. Within-run and within-assay CVs were draught horses and so combined reference intervals (2.5-97.5%) were calculated for total protein (51.0-72.0 g/L), albumin (29.6-38.5 g/L), alpha(1)-globulin (1.9-3.1 g/L), alpha(2)-globulin (5.3-8.7 g/L), beta(1)-globulin (2.8-7.3g/L), beta(2)-globulin (2.2-6.0 g/L), and gamma-globulin (5.8-12.7 g/L) concentrations, and albumin/globulin ratio (0.93-1.65). Using agarose gel as the supporting matrix for serum protein electrophoresis in horses resulted in excellent resolution and accurate results that facilitated standardization into 6 protein fractions.

  8. 7 CFR 1467.9 - Wetlands Reserve Enhancement Program.

    Science.gov (United States)

    2010-01-01

    ..., restoration, and enhancement objectives through agreements with States (including a political subdivision or... project. (b) Reserved Rights Pilot. (1) The Chief shall carry out a reserved rights pilot subject to the requirements established in this part. (2) Under the reserved rights pilot, a landowner may reserve grazing...

  9. Western Blotting using Capillary Electrophoresis

    OpenAIRE

    Anderson, Gwendolyn J.; Cipolla, Cynthia; Kennedy, Robert T.

    2011-01-01

    A microscale Western blotting system based on separating sodium-dodecyl sulfate protein complexes by capillary gel electrophoresis followed by deposition onto a blotting membrane for immunoassay is described. In the system, the separation capillary is grounded through a sheath capillary to a mobile X-Y translation stage which moves a blotting membrane past the capillary outlet for protein deposition. The blotting membrane is moistened with a methanol and buffer mixture to facilitate protein a...

  10. Analysis of Two-Dimensional Electrophoresis Gel Images

    DEFF Research Database (Denmark)

    Pedersen, Lars

    2002-01-01

    This thesis describes and proposes solutions to some of the currently most important problems in pattern recognition and image analysis of two-dimensional gel electrophoresis (2DGE) images. 2DGE is the leading technique to separate individual proteins in biological samples with many biological...

  11. Role of capillary electrophoresis in the fight against doping in sports.

    Science.gov (United States)

    Harrison, Christopher R

    2013-08-06

    At present the role of capillary electrophoresis in the detection of doping agents in athletes is, for the most part, nonexistent. More traditional techniques, namely gas and liquid chromatography with mass spectrometric detection, remain the gold standard of antidoping tests. This Feature will investigate the in-roads that capillary electrophoresis has made, the limitations that the technique suffers from, and where the technique may grow into being a key tool for antidoping analysis.

  12. Gel versus capillary electrophoresis genotyping for categorizing treatment outcomes in two anti-malarial trials in Uganda

    Directory of Open Access Journals (Sweden)

    Hubbard Alan E

    2010-01-01

    Full Text Available Abstract Background Molecular genotyping is performed in anti-malarial trials to determine whether recurrent parasitaemia after therapy represents a recrudescence (treatment failure or new infection. The use of capillary instead of agarose gel electrophoresis for genotyping offers technical advantages, but it is unclear whether capillary electrophoresis will result in improved classification of anti-malarial treatment outcomes. Methods Samples were genotyped using both gel and capillary electrophoresis from randomized trials of artemether-lumefantrine (AL vs. dihydroartemisinin-piperaquine (DP performed in two areas of Uganda: Kanungu, where transmission is moderate, and Apac, where transmission is very high. Both gel and capillary methods evaluated polymorphic regions of the merozoite surface protein 1 and 2 and glutamine rich protein genes. Results Capillary electrophoresis detected more alleles and provided higher discriminatory power than agarose gel electrophoresis at both study sites. There was only moderate agreement between classification of outcomes with the two methods in Kanungu (kappa = 0.66 and poor agreement in Apac (kappa = 0.24. Overall efficacy results were similar when using gel vs. capillary methods in Kanungu (42-day risk of treatment failure for AL: 6.9% vs. 5.5%, p = 0.4; DP 2.4% vs. 2.9%, p = 0.5. However, the measured risk of recrudescence was significantly higher when using gel vs. capillary electrophoresis in Apac (risk of treatment failure for AL: 17.0% vs. 10.7%, p = 0.02; DP: 8.5% vs. 3.4%, p = 0.03. Risk differences between AL and DP were not significantly different whether gel or capillary methods were used. Conclusions Genotyping with gel electrophoresis overestimates the risk of recrudescence in anti-malarial trials performed in areas of high transmission intensity. Capillary electrophoresis provides more accurate outcomes for such trials and should be performed when possible. In areas of moderate transmission

  13. Gel versus capillary electrophoresis genotyping for categorizing treatment outcomes in two anti-malarial trials in Uganda.

    Science.gov (United States)

    Gupta, Vinay; Dorsey, Grant; Hubbard, Alan E; Rosenthal, Philip J; Greenhouse, Bryan

    2010-01-15

    Molecular genotyping is performed in anti-malarial trials to determine whether recurrent parasitaemia after therapy represents a recrudescence (treatment failure) or new infection. The use of capillary instead of agarose gel electrophoresis for genotyping offers technical advantages, but it is unclear whether capillary electrophoresis will result in improved classification of anti-malarial treatment outcomes. Samples were genotyped using both gel and capillary electrophoresis from randomized trials of artemether-lumefantrine (AL) vs. dihydroartemisinin-piperaquine (DP) performed in two areas of Uganda: Kanungu, where transmission is moderate, and Apac, where transmission is very high. Both gel and capillary methods evaluated polymorphic regions of the merozoite surface protein 1 and 2 and glutamine rich protein genes. Capillary electrophoresis detected more alleles and provided higher discriminatory power than agarose gel electrophoresis at both study sites. There was only moderate agreement between classification of outcomes with the two methods in Kanungu (kappa = 0.66) and poor agreement in Apac (kappa = 0.24). Overall efficacy results were similar when using gel vs. capillary methods in Kanungu (42-day risk of treatment failure for AL: 6.9% vs. 5.5%, p = 0.4; DP 2.4% vs. 2.9%, p = 0.5). However, the measured risk of recrudescence was significantly higher when using gel vs. capillary electrophoresis in Apac (risk of treatment failure for AL: 17.0% vs. 10.7%, p = 0.02; DP: 8.5% vs. 3.4%, p = 0.03). Risk differences between AL and DP were not significantly different whether gel or capillary methods were used. Genotyping with gel electrophoresis overestimates the risk of recrudescence in anti-malarial trials performed in areas of high transmission intensity. Capillary electrophoresis provides more accurate outcomes for such trials and should be performed when possible. In areas of moderate transmission, gel electrophoresis appears adequate to estimate comparative

  14. A new electrophoresis technique to separate microsatellite alleles ...

    African Journals Online (AJOL)

    A new electrophoresis technique to separate microsatellite alleles* ... African Journal of Biotechnology ... with the CEQTM 8000 Genetic Analysis System and ABI 3130xl DNA Sequencer easily separated products and determined allelic size, ...

  15. Determination of five nitroimidazole residues in artificial porcine muscle tissue samples by capillary electrophoresis.

    Science.gov (United States)

    Lin, Yingyun; Su, Yan; Liao, Xiulin; Yang, Na; Yang, Xiupei; Choi, Martin M F

    2012-01-15

    A capillary electrophoresis (CE) method with ultraviolet detection has been developed for simultaneous detection and quantification of five nitroimidazoles including benzoylmetronidazole, dimetridazole, metronidazole, ronidazole, and secnidazole in porcine muscles. Nitroimidazoles in samples were extracted by ethyl acetate with subsequent clean-up by a strong cation exchange solid phase extraction column. The clean extracts were subjected to CE separation with optimal experimental conditions: pH 3.0 running buffer containing 25mM sodium phosphate and 0.10mM tetrabutylammonium bromide, 5s hydrodynamic injection at 0.5psi and 28kV separation voltage. The nitroimidazoles could be monitored and detected at 320nm within 18min. The limits of detection were below 1.0μg/kg and limits of quantification were lower than 3.2μg/kg for all nitroimidazoles in the muscle samples. The recoveries and relative standard deviations were 85.4-96.0, 83.5-92.5, 1.3-3.9, and 1.1-4.2%, respectively for the intra-day and inter-day analyses. The proposed CE method has been successfully applied to determine nitroimidazoles in artificial porcine muscle samples with good accuracy and recovery, demonstrating that it has potential for detection and quantification of multi-nitroimidazole residue in real muscle samples. Copyright © 2011 Elsevier B.V. All rights reserved.

  16. Development of a fast capillary electrophoresis method for determination of carbohydrates in honey samples.

    Science.gov (United States)

    Rizelio, Viviane Maria; Tenfen, Laura; da Silveira, Roberta; Gonzaga, Luciano Valdemiro; Costa, Ana Carolina Oliveira; Fett, Roseane

    2012-05-15

    In this study, the determination of fructose, glucose and sucrose by capillary electrophoresis (CE) was investigated. The tendency of the analyte to undergo electromigration dispersion and the buffer capacity were evaluated using the Peakmaster(®) software and considered in the optimization of the background electrolyte, which was composed of 20 mmol L(-1) sorbic acid, 0.2 mmol L(-1) CTAB and 40 mmol L(-1) NaOH at pH 12.2. Under optimal CE conditions, the separation of the substances investigated was achieved in less than 2 min. The detection limits for the three analytes were in the range of 0.022 and 0.029 g L(-1) and precision measurements within 0.62-4.69% were achieved. The proposed methodology was applied in the quantitative analysis by direct injection of in honey samples to determine the main sugars presents. The samples were previously dissolved in deionized water and filtered with no other sample treatment. The mean values for fructose, glucose and sucrose were in the ranges of 33.65-45.46 g 100g(-1), 24.63-35.06 g 100g(-1) and <0.22-1.32 g 100g(-1), respectively. The good analytical performance of the method makes it suitable for implementation in food laboratories for the routine analysis of honey samples. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Echocardiographic and hemodynamic determinants of right coronary artery flow reserve and phasic flow pattern in advanced non-ischemic cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Mady Charles

    2007-09-01

    Full Text Available Abstract Background In patients with advanced non-ischemic cardiomyopathy (NIC, right-sided cardiac disturbances has prognostic implications. Right coronary artery (RCA flow pattern and flow reserve (CFR are not well known in this setting. The purpose of this study was to assess, in human advanced NIC, the RCA phasic flow pattern and CFR, also under right-sided cardiac disturbances, and compare with left coronary circulation. As well as to investigate any correlation between the cardiac structural, mechanical and hemodynamic parameters with RCA phasic flow pattern or CFR. Methods Twenty four patients with dilated severe NIC were evaluated non-invasively, even by echocardiography, and also by cardiac catheterization, inclusive with Swan-Ganz catheter. Intracoronary Doppler (Flowire data was obtained in RCA and left anterior descendent coronary artery (LAD before and after adenosine. Resting RCA phasic pattern (diastolic/systolic was compared between subgroups with and without pulmonary hypertension, and with and without right ventricular (RV dysfunction; and also with LAD. RCA-CFR was compared with LAD, as well as in those subgroups. Pearson's correlation analysis was accomplished among echocardiographic (including LV fractional shortening, mass index, end systolic wall stress more hemodynamic parameters with RCA phasic flow pattern or RCA-CFR. Results LV fractional shortening and end diastolic diameter were 15.3 ± 3.5 % and 69.4 ± 12.2 mm. Resting RCA phasic pattern had no difference comparing subgroups with vs. without pulmonary hypertension (1.45 vs. 1.29, p = NS either with vs. without RV dysfunction (1.47 vs. 1.23, p = NS; RCA vs. LAD was 1.35 vs. 2.85 (p Conclusion In patients with chronic advanced NIC, RCA phasic flow pattern has a mild diastolic predominance, less marked than in LAD, with no effects from pulmonary artery hypertension or RV dysfunction. There is no significant correlation between any cardiac mechanical-structural or

  18. Sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS ...

    African Journals Online (AJOL)

    Four strains of eri, Samia cynthia ricini Lepidoptera: Saturniidae that can be identified morphologically and maintained at North East Institute of Science and Technology, Jorhat were characterized based on their protein profile by sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) and DNA by random ...

  19. Electrophoresis test prevalence, requesting patterns, yield and ...

    African Journals Online (AJOL)

    Most of the appropriate SPE test requests were from clinical haematology, renal ... implementation of principles of demand management and the ... electrophoresis (IFE)) in a South African (SA) pathology laboratory setting are limited. Objectives. ... (NHLS) hospital information system database from 1 July 2010 to. 30 June ...

  20. Tunable separations based on a molecular size effect for biomolecules by poly(ethylene glycol) gel-based capillary electrophoresis.

    Science.gov (United States)

    Kubo, Takuya; Nishimura, Naoki; Furuta, Hayato; Kubota, Kei; Naito, Toyohiro; Otsuka, Koji

    2017-11-10

    We report novel capillary gel electrophoresis (CGE) with poly(ethylene glycol) (PEG)-based hydrogels for the effective separations of biomolecules containing sugars and DNAs based on a molecular size effect. The gel capillaries were prepared in a fused silica capillary modified with 3-(trimethoxysilyl)propylmethacrylate using a variety of the PEG-based hydrogels. After the fundamental evaluations in CGE regarding the separation based on the molecular size effect depending on the crosslinking density, the optimized capillary provided the efficient separation of glucose ladder (G1 to G20). In addition, another capillary showed the successful separation of DNA ladder in the range of 10-1100 base pair, which is superior to an authentic acrylamide-based gel capillary. For both glucose and DNA ladders, the separation ranges against the molecular size were simply controllable by alteration of the concentration and/or units of ethylene oxide in the PEG-based crosslinker. Finally, we demonstrated the separations of real samples, which included sugars carved out from monoclonal antibodies, mAbs, and then the efficient separations based on the molecular size effect were achieved. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Mutation screening of the TP53 gene by temporal temperature gradient gel electrophoresis.

    Science.gov (United States)

    Sørlie, Therese; Johnsen, Hilde; Vu, Phuong; Lind, Guro Elisabeth; Lothe, Ragnhild; Børresen-Dale, Anne-Lise

    2005-01-01

    A protocol for detection of mutations in the TP53 gene using temporal temperature gradient gel electrophoresis (TTGE) is described. TTGE is a mutation detection technique that separates DNA fragments differing by single base pairs according to their melting properties in a denaturing gel. It is based on constant denaturing conditions in the gel combined with a temperature gradient during the electrophoretic run. This method combines some of the advantages of the related techniques denaturing gradient gel electrophoresis (DGGE) and constant denaturant gel electrophoresis (CDGE) and eliminates some of the problems. The result is a rapid and sensitive screening technique that is robust and easily set up in smaller laboratory environments.

  2. Mutation screening of the TP53 gene by temporal temperature gel electrophoresis (TTGE).

    Science.gov (United States)

    Sørlie, Therese; Johnsen, Hilde; Vu, Phuong; Lind, Guro Elisabeth; Lothe, Ragnhild; Børresen-Dale, Anne-Lise

    2014-01-01

    A protocol for detection of mutations in the TP53 gene using temporal temperature gradient electrophoresis (TTGE) is described. TTGE is a mutation detection technique that separates DNA fragments differing by single base pairs according to their melting properties in a denaturing gel. It is based on constant denaturing conditions in the gel combined with a temperature gradient during the electrophoretic run. This method combines some of the advantages of the related techniques, denaturing gradient gel electrophoresis and constant denaturant gel electrophoresis, and eliminates some of the problems. The result is a rapid and sensitive screening technique which is robust and easily set up in smaller laboratory environments.

  3. Preparation of Barley Storage Protein, Hordein, for Analytical Sodium Dodecyl Sulfate-Polyacrylamide Gel Electrophoresis

    DEFF Research Database (Denmark)

    Doll, Hans; Andersen, Bente

    1981-01-01

    The extraction, reduction, and alkylation of barley hordein for routine electrophoresis in sodium dodecyl sulfate-polyacrylamide gels were studied to set up a simple preparation procedure giving well-resolved bands in the electrophoresis gel. Hordein was extracted from single crushed seeds or flour...... by aqueous 50% propan-2-ol containing a Tris-borate buffer, pH 8.6. The presence of the buffer facilitates the consecutive complete reduction of the extracted protein in the alcohol. Reduction and alkylation in the buffer containing propan-2-ol give sharper bands in the electrophoresis than reduction...

  4. Development of two dimensional electrophoresis method using single chain DNA

    International Nuclear Information System (INIS)

    Ikeda, Junichi; Hidaka, So

    1998-01-01

    By combining a separation method due to molecular weight and a method to distinguish difference of mono-bases, it was aimed to develop a two dimensional single chain DNA labeled with Radioisotope (RI). From electrophoretic pattern difference of parent and variant strands, it was investigated to isolate the root module implantation control gene. At first, a Single Strand Conformation Polymorphism (SSCP) method using concentration gradient gel was investigated. As a result, it was formed that intervals between double chain and single chain DNAs expanded, but intervals of both single chain DNAs did not expand. On next, combination of non-modified acrylic amide electrophoresis method and Denaturing Gradient-Gel Electrophoresis (DGGE) method was examined. As a result, hybrid DNA developed by two dimensional electrophoresis arranged on two lines. But, among them a band of DNA modified by high concentration of urea could not be found. Therefore, in this fiscal year's experiments, no preferable result could be obtained. By the used method, it was thought to be impossible to detect the differences. (G.K.)

  5. Detecting irradiation of seeds using microgel electrophoresis (a collaborative trial)

    International Nuclear Information System (INIS)

    Cerda, H.; Haine, H.E.; Jones, J.L.

    1995-06-01

    Preservation of certain foods by irradiation is permitted in the United Kingdom. However, all irradiated foods must be labelled as such, to ensure consumer choice. To help enforce labelling, a variety of methods have been developed for distinguishing between irradiated and non-irradiated foods. In preliminary trials, microgel electrophoresis -a simple method of assessing DNA damage - has shown considerable promise in this respect. This report describes microgel electrophoresis, and details results obtained in a blind trial carried out in collaboration with the Swedish University of Agricultural Sciences. Microgel electrophoresis facilitates analysis of the leakage of DNA from cells extracted from food material. In irradiated samples, the DNA is fragmented and will leak from cells in an electric current. This leakage can be seen as a 'comet' when the stained gel is viewed with a microscope. The size and shape of the comet can be used to estimate the irradiation dose administered to the sample. In non-irradiated samples the DNA is less fragmented, will tend not to leak from the cells and will not form a comet. (author)

  6. Methods and instrumentation for quantitative microchip capillary electrophoresis

    NARCIS (Netherlands)

    Revermann, T.

    2007-01-01

    The development of novel instrumentation and analytical methodology for quantitative microchip capillary electrophoresis (MCE) is described in this thesis. Demanding only small quantities of reagents and samples, microfluidic instrumentation is highly advantageous. Fast separations at high voltages

  7. Analysis of rRNA gene methylation in Arabidopsis thaliana by CHEF-Conventional 2D gel electrophoresis

    Science.gov (United States)

    Mohannath, Gireesha; Pikaard, Craig S.

    2017-01-01

    Summary Contour-clamped homogenous electric field (CHEF) gel electrophoresis, a variant of Pulsed-field gel electrophoresis (PFGE), is a powerful technique for resolving large fragments of DNA (10 kb to 9 Mb). CHEF has many applications including the physical mapping of chromosomes, artificial chromosomes and sub-chromosomal DNA fragments, etc. Here we describe the use of CHEF and two-dimensional gel electrophoresis to analyze rRNA gene methylation patterns within the two ~ 4 million base pair nucleolus organizer regions (NORs) of Arabidopsis thaliana. The method involves CHEF gel electrophoresis of agarose-embedded DNA following restriction endonuclease digestion to cut the NORs into large but resolvable segments, followed by digestion with methylation-sensitive restriction endonucleases and conventional (or CHEF) gel electrophoresis, in a second dimension. Resulting products are then detected by Southern blotting or PCR analyses capable of discriminating rRNA gene subtypes. PMID:27576719

  8. Capillary electrophoresis systems and methods

    Science.gov (United States)

    Dorairaj, Rathissh [Hillsboro, OR; Keynton, Robert S [Louisville, KY; Roussel, Thomas J [Louisville, KY; Crain, Mark M [Georgetown, IN; Jackson, Douglas J [New Albany, IN; Walsh, Kevin M [Louisville, KY; Naber, John F [Goshen, KY; Baldwin, Richard P [Louisville, KY; Franco, Danielle B [Mount Washington, KY

    2011-08-02

    An embodiment of the invention is directed to a capillary electrophoresis apparatus comprising a plurality of separation micro-channels. A sample loading channel communicates with each of the plurality of separation channels. A driver circuit comprising a plurality of electrodes is configured to induce an electric field across each of the plurality of separation channels sufficient to cause analytes in the samples to migrate along each of the channels. The system further comprises a plurality of detectors configured to detect the analytes.

  9. The Optimization of Electrophoresis on a Glass Microfluidic Chip and its Application in Forensic Science.

    Science.gov (United States)

    Han, Jun P; Sun, Jing; Wang, Le; Liu, Peng; Zhuang, Bin; Zhao, Lei; Liu, Yao; Li, Cai X

    2017-11-01

    Microfluidic chips offer significant speed, cost, and sensitivity advantages, but numerous parameters must be optimized to provide microchip electrophoresis detection. Experiments were conducted to study the factors, including sieving matrices (the concentration and type), surface modification, analysis temperature, and electric field strengths, which all impact the effectiveness of microchip electrophoresis detection of DNA samples. Our results showed that the best resolution for ssDNA was observed using 4.5% w/v (7 M urea) lab-fabricated LPA gel, dynamic wall coating of the microchannel, electrophoresis temperatures between 55 and 60°C, and electrical fields between 350 and 450 V/cm on the microchip-based capillary electrophoresis (μCE) system. One base-pair resolution could be achieved in the 19-cm-length microchannel. Furthermore, both 9947A standard genomic DNA and DNA extracted from blood spots were demonstrated to be successfully separated with well-resolved DNA peaks in 8 min. Therefore, the microchip electrophoresis system demonstrated good potential for rapid forensic DNA analysis. © 2017 American Academy of Forensic Sciences.

  10. Gel Electrophoresis--The Easy Way for Students

    Science.gov (United States)

    VanRooy, Wilhelmina; Sultana, Khalida

    2010-01-01

    This article describes a simple, inexpensive, easy to conduct gel-electrophoresis activity using food dyes. It is an alternative to the more expensive counterparts which require agarose gel, DNA samples, purchased chamber and Tris-borate-EDTA buffer. We suggest some learning activities for senior biology students along with comments on several…

  11. Capillary Electrophoresis Analysis of Conventional Splicing Assays

    DEFF Research Database (Denmark)

    de Garibay, Gorka Ruiz; Acedo, Alberto; García-Casado, Zaida

    2014-01-01

    of these assays is often challenging. Here, we explore this issue by conducting splicing assays in 31 BRCA2 genetic variants. All variants were assessed by RT-PCR followed by capillary electrophoresis and direct sequencing. If assays did not produce clear-cut outputs (Class-2 or Class-5 according to analytical...

  12. All rights reserved

    African Journals Online (AJOL)

    ADOWIE PERE

    ABSTRACT: The influence of weather in all aspects of human endeavours is evident in the recorded loss of lives and properties .... forecasting the rain, frost and fog formation as well as ... 2017). The trend graphs of relative humidity and the ... equation was obtained using the curve estimation .... empirical regression models.

  13. The new horizon in 2D electrophoresis: new technology to increase resolution and sensitivity.

    Science.gov (United States)

    Moche, Martin; Albrecht, Dirk; Maaß, Sandra; Hecker, Michael; Westermeier, Reiner; Büttner, Knut

    2013-06-01

    A principally new type of an electrophoresis setup for the second dimension of 2DE named HPE (high performance electrophoresis) has recently become available that provides excellent reproducibility much superior to traditional 2DE. It takes up ideas from early beginnings of 2DE which could not be satisfactory realized at that time. The new HPE system is in contrast to all other established systems a horizontal electrophoresis that employs a new type of precast polyacrylamide gels on film-backing and runs on a multilevel flatbed electrophoresis apparatus. In a systematic approach we compared its features to traditional 2DE for the cytosolic proteome of Bacillus subtilis. Not only the reproducibility is enhanced, but also nearly all qualitative parameters as resolution, sensitivity, the number of protein spots (25% more), and the number of different proteins (also additional 25%) are markedly increased. More than 200 proteins were exclusively found in HPE. This new electrophoresis system does not use buffer tanks. No glass plates are needed. Therefore handling of gels is greatly facilitated and very simple to use even for personnel with low technical skills. The new HPE system is technically at the beginnings and further development with increased performance can be expected. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Qualitative and quantitative assessment of DNA quality of frozen beef based on DNA yield, gel electrophoresis and PCR amplification and their correlations to beef quality.

    Science.gov (United States)

    Zhao, Jing; Zhang, Ting; Liu, Yongfeng; Wang, Xingyu; Zhang, Lan; Ku, Ting; Quek, Siew Young

    2018-09-15

    Freezing is a practical method for meat preservation but the quality of frozen meat can deteriorate with storage time. This research investigated the effect of frozen storage time (up to 66 months) on changes in DNA yield, purity and integrity in beef, and further analyzed the correlation between beef quality (moisture content, protein content, TVB-N value and pH value) and DNA quality in an attempt to establish a reliable, high-throughput method for meat quality control. Results showed that frozen storage time influenced the yield and integrity of DNA significantly (p quality degraded dramatically with the increased storage time based on gel electrophoresis results. Polymerase chain reaction (PCR) products from both mitochondrial DNA (mtDNA) and nuclear DNA (nDNA) were observed in all frozen beef samples. Using real-time PCR for quantitative assessment of DNA and meat quality revealed that correlations could be established successfully with mathematical models to evaluate frozen beef quality. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Acid-Urea Gel Electrophoresis and Western Blotting of Histones.

    Science.gov (United States)

    Hazzalin, Catherine A; Mahadevan, Louis C

    2017-01-01

    Acid-urea gel electrophoresis offers significant advantages over SDS-PAGE for analysis of post-translational protein modifications, being capable of resolving proteins of similar size but varying in charge. Hence, it can be used to separate protein variants with small charge-altering differences in primary sequence, and is particularly useful in the analysis of histones whose charge variation arises from post-translational modification, such as phosphorylation or acetylation. On acid-urea gels, histones that carry multiple modifications, each with a characteristic charge, are resolved into distinct bands, the so-called "histone ladder." Thus, the extent and distribution of different modification states of histones can be visualized. Here, we describe the analysis of histone H3 by acid-urea gel electrophoresis and western blotting.

  16. The fluid mechanics of continuous flow electrophoresis

    Science.gov (United States)

    Saville, D. A.

    1990-01-01

    The overall objective is to establish theoretically and confirm experimentally the ultimate capabilities of continuous flow electrophoresis chambers operating in an environment essentially free of particle sedimentation and buoyancy. The efforts are devoted to: (1) studying the effects of particle concentration on sample conductivity and dielectric constant. The dielectric constant and conductivity were identified as playing crucial roles in the behavior of the sample and on the resolving power and throughput of continuous flow devices; and (2) improving the extant mathematical models to predict flow fields and particle trajectories in continuous flow electrophoresis. A dielectric spectrometer was designed and built to measure the complex dielectric constant of a colloidal dispersion as a function of frequency between 500 Hz and 200 kHz. The real part of the signal can be related to the sample's conductivity and the imaginary part to its dielectric constant. Measurements of the dielectric constants of several different dispersions disclosed that the dielectric constants of dilute systems of the sort encountered in particle electrophoresis are much larger than would be expected based on the extant theory. Experiments were carried out to show that, in many cases, this behavior is due to the presence of a filamentary structure of small hairs on the particle surface. A technique for producing electrokinetically ideal synthetic latex particles by heat treating was developed. Given the ubiquitous nature of hairy surfaces with both cells and synthetic particles, it was deemed necessary to develop a theory to explain their behavior. A theory for electrophoretic mobility of hairy particles was developed. Finally, the extant computer programs for predicting the structure of electro-osmotically driven flows were extended to encompass flow channels with variable wall mobilities.

  17. Combination of micelle collapse and field-amplified sample stacking in capillary electrophoresis for determination of trimethoprim and sulfamethoxazole in animal-originated foodstuffs.

    Science.gov (United States)

    Liu, Lihong; Wan, Qian; Xu, Xiaoying; Duan, Shunshan; Yang, Chunli

    2017-03-15

    An on-line preconcentration method combining micelle to solvent stacking (MSS) with field-amplified sample stacking (FASS) was employed for the analysis of trimethoprim (TMP) and sulfamethoxazole (SMZ) by capillary zone electrophoresis (CZE). The optimized experimental conditions were as followings: (1) sample matrix, 10.0mM SDS-5% (v/v) methanol; (2) trapping solution (TS), 35mM H 3 PO 4 -60% acetonitrile (CH 3 CN); (3) running buffer, 30mM Na 2 HPO 4 (pH=7.3); (4) sample solution volume, 168nL; TS volume, 168nL; and (5) 9kV voltage, 214nm UV detection. Under the optimized conditions, the limits of detection (LODs) for SMZ and TMP were 7.7 and 8.5ng/mL, and they were 301 and 329 times better compared to a typical injection, respectively. The contents of TMP and SMZ in animal foodstuffs such as dairy products, eggs and honey were analyzed, too. Recoveries of 80-104% were acquired with relative standard deviations of 0.5-5.4%. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Studies of transferin polymorphism in Swedish cattle using agarose gel electrophoresis

    International Nuclear Information System (INIS)

    Liberg, P.; Carlstroem, G.

    1976-01-01

    The polymorphic transferrin picture in the sera from 894 Swedish cattle was investigated with an agarose gel electrophoresis technique. The serum transferrin bands in the electrophoresis pattern were first identified by labelling with 59 Fe. Six existing phenotypes based on the alleles Tf(supA), Tf(supD) and Tf(supE) could be detected. The frequencies of transferrin types and transferrin alleles are presented, and it is concluded that there are great differences in the frequencis between the Swedish Red and White and the Swedish Friesian. (author)

  19. Attempt to run urinary protein electrophoresis using capillary technique.

    Science.gov (United States)

    Falcone, Michele

    2014-10-01

    The study of urinary protein has a predominant place in the diagnosis of kidney disease. The most common technique is agarose gel electrophoresis (AGE). For several years, the technique of choice applied to the analysis of serum proteins has been CE, a system that uses capillary fused silica, subjected to high voltage to separate and measure serum proteins. The purpose of this paper was to perform capillary electrophoresis on urinary proteins which, at present, are not interpretable due to the many nonspecific peaks visible when using gel electrophoresis. In order to carry out our research, we used a capillary V8 analyzer together with an agarose gel system from the same company. AGE was taken as the reference method, for which urine was used without any pretreatment. For the V8 system, urine was subjected to purification on granular-activated carbon and then inserted into the V8 analyzer, selecting a program suitable for liquids with low protein content. We examined 19 urine samples collected over 24 hrs from both hospitalized and external patients with different types of proteinuria plus a serum diluted 1/61 considered as a control to recognize the bands. Both methods showed the same protein fractions and classified the proteinuria in a similar way. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. An analytical model for enantioseparation process in capillary electrophoresis

    Science.gov (United States)

    Ranzuglia, G. A.; Manzi, S. J.; Gomez, M. R.; Belardinelli, R. E.; Pereyra, V. D.

    2017-12-01

    An analytical model to explain the mobilities of enantiomer binary mixture in capillary electrophoresis experiment is proposed. The model consists in a set of kinetic equations describing the evolution of the populations of molecules involved in the enantioseparation process in capillary electrophoresis (CE) is proposed. These equations take into account the asymmetric driven migration of enantiomer molecules, chiral selector and the temporary diastomeric complexes, which are the products of the reversible reaction between the enantiomers and the chiral selector. The solution of these equations gives the spatial and temporal distribution of each species in the capillary, reproducing a typical signal of the electropherogram. The mobility, μ, of each specie is obtained by the position of the maximum (main peak) of their respective distributions. Thereby, the apparent electrophoretic mobility difference, Δμ, as a function of chiral selector concentration, [ C ] , can be measured. The behaviour of Δμ versus [ C ] is compared with the phenomenological model introduced by Wren and Rowe in J. Chromatography 1992, 603, 235. To test the analytical model, a capillary electrophoresis experiment for the enantiomeric separation of the (±)-chlorpheniramine β-cyclodextrin (β-CD) system is used. These data, as well as, other obtained from literature are in closed agreement with those obtained by the model. All these results are also corroborate by kinetic Monte Carlo simulation.

  1. Approach to analysis of single nucleotide polymorphisms by automated constant denaturant capillary electrophoresis

    International Nuclear Information System (INIS)

    Bjoerheim, Jens; Abrahamsen, Torveig Weum; Kristensen, Annette Torgunrud; Gaudernack, Gustav; Ekstroem, Per O.

    2003-01-01

    Melting gel techniques have proven to be amenable and powerful tools in point mutation and single nucleotide polymorphism (SNP) analysis. With the introduction of commercially available capillary electrophoresis instruments, a partly automated platform for denaturant capillary electrophoresis with potential for routine screening of selected target sequences has been established. The aim of this article is to demonstrate the use of automated constant denaturant capillary electrophoresis (ACDCE) in single nucleotide polymorphism analysis of various target sequences. Optimal analysis conditions for different single nucleotide polymorphisms on ACDCE are evaluated with the Poland algorithm. Laboratory procedures include only PCR and electrophoresis. For direct genotyping of individual SNPs, the samples are analyzed with an internal standard and the alleles are identified by co-migration of sample and standard peaks. In conclusion, SNPs suitable for melting gel analysis based on theoretical thermodynamics were separated by ACDCE under appropriate conditions. With this instrumentation (ABI 310 Genetic Analyzer), 48 samples could be analyzed without any intervention. Several institutions have capillary instrumentation in-house, thus making this SNP analysis method accessible to large groups of researchers without any need for instrument modification

  2. Design and operation of a portable scanner for high performance microchip capillary array electrophoresis.

    Science.gov (United States)

    Scherer, James R; Liu, Peng; Mathies, Richard A

    2010-11-01

    We have developed a compact, laser-induced fluorescence detection scanner, the multichannel capillary array electrophoresis portable scanner (McCAEPs) as a platform for electrophoretic detection and control of high-throughput, integrated microfluidic devices for genetic and other analyses. The instrument contains a confocal optical system with a rotary objective for detecting four different fluorescence signals, a pneumatic system consisting of two pressure/vacuum pumps and 28 individual addressable solenoid valves for control of on-chip microvalves and micropumps, four Polymerase Chain Reaction (PCR) temperature control systems, and four high voltage power supplies for electrophoresis. The detection limit of the instrument is ~20 pM for on-chip capillary electrophoresis of fluorescein dyes. To demonstrate the system performance for forensic short tandem repeat (STR) analysis, two experiments were conducted: (i) electrophoretic separation and detection of STR samples on a 96-lane microfabricated capillary array electrophoresis microchip. Fully resolved PowerPlex(®) 16 STR profiles amplified from 1 ng of 9947A female standard DNA were successfully obtained; (ii) nine-plex STR amplification, sample injection, separation, and fluorescence detection of 100-copy 9948 male standard DNA in a single integrated PCR- capillary electrophoresis microchip. These results demonstrate that the McCAEPs can be used as a versatile control and detection instrument that operates integrated microfluidic devices for high-performance forensic human identification.

  3. Capillary zone electrophoresis-mass spectromet of intact proteins

    NARCIS (Netherlands)

    Domínguez-Vega, Elena; Haselberg, Rob; Somsen, Govert W.

    2016-01-01

    Capillary electrophoresis (CE) coupled with mass spectrometry (MS) has proven to be a powerful analytical tool for the characterization of intact proteins. It combines the high separation efficiency, short analysis time, and versatility of CE with the mass selectivity and sensitivity offered by MS

  4. Routine hemoglobin electrophoresis for pediatric surgery day case ...

    African Journals Online (AJOL)

    Background: Hemoglobin electrophoresis (HBE) is a part of the preoperative routine requested by anesthetists. However, the prevalence of hemoglobinopathy in the population is low. This study aims to determine the clinical risk factors for hemoglobinopathies and propose clinical guidelines for preoperative screening of ...

  5. Separation and Species Characterization of Complex Compound of Yttrium-90 and Strontium-90 by Paper Electrophoresis

    International Nuclear Information System (INIS)

    Sulaiman; Adang Hardi G; Noor Anis Kundari

    2007-01-01

    The research for species characterization of 90 Y and 90 Sr complex compound have been conducted using variation of buffer, concentration of HCl, electrophoresis operation voltage, time of electrophoresis, and electrophoresis migration media. From many trials, the conclusions are the applicable buffer are tartrate buffer and citrate buffer. These buffers can make a complex compound of 90 Y and there is migration to the anode. But, 90 Sr can’t make any complex compound and migration to the cathode. The optimum concentration of hydrochloride acid is 8 M with tartrate buffer but for citrate buffer, the concentration HCl is 2 M. The hydrochloric acid is used to dissolved the both elements as the mentioned above, but also for making complex ligand. The optimum electrophoresis operation voltage is 200 Volt for the both buffer solution and the duration of electrophoresis operation is 2.5 hours with using tartrate buffer but for citrate buffer the duration is 2 hours. The media of migration which can be used for replacing paper is silica. (author)

  6. Capillary electrophoresis in the N-glycosylation analysis of biopharmaceuticals

    Czech Academy of Sciences Publication Activity Database

    Guttman, András

    2013-01-01

    Roč. 48, JUL-AUG (2013), s. 132-143 ISSN 0165-9936 Institutional support: RVO:68081715 Keywords : automated workflow * biopharmaceuticals * capillary electrophoresis Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 6.612, year: 2013

  7. Detection system of capillary array electrophoresis microchip based on optical fiber

    Science.gov (United States)

    Yang, Xiaobo; Bai, Haiming; Yan, Weiping

    2009-11-01

    To meet the demands of the post-genomic era study and the large parallel detections of epidemic diseases and drug screening, the high throughput micro-fluidic detection system is needed urgently. A scanning laser induced fluorescence detection system based on optical fiber has been established by using a green laser diode double-pumped solid-state laser as excitation source. It includes laser induced fluorescence detection subsystem, capillary array electrophoresis micro-chip, channel identification unit and fluorescent signal processing subsystem. V-shaped detecting probe composed with two optical fibers for transmitting the excitation light and detecting induced fluorescence were constructed. Parallel four-channel signal analysis of capillary electrophoresis was performed on this system by using Rhodamine B as the sample. The distinction of different samples and separation of samples were achieved with the constructed detection system. The lowest detected concentration is 1×10-5 mol/L for Rhodamine B. The results show that the detection system possesses some advantages, such as compact structure, better stability and higher sensitivity, which are beneficial to the development of microminiaturization and integration of capillary array electrophoresis chip.

  8. Characterization and Study of Transgenic Cultivars by Capillary and Microchip Electrophoresis

    Directory of Open Access Journals (Sweden)

    Elena Domínguez Vega

    2014-12-01

    Full Text Available Advances in biotechnology have increased the demand for suitable analytical techniques for the analysis of genetically modified organisms. Study of the substantial equivalence, discrimination between transgenic and non-transgenic cultivars, study of the unintended effects caused by a genetic modification or their response to diverse situations or stress conditions (e.g., environmental, climatic, infections are some of the concerns that need to be addressed. Capillary electrophoresis (CE is emerging as an alternative to conventional techniques for the study and characterization of genetically modified organisms. This article reviews the most recent applications of CE for the analysis and characterization of transgenic cultivars in the last five years. Different strategies have been described depending on the level analyzed (DNA, proteins or metabolites. Capillary gel electrophoresis (CGE has shown to be particularly useful for the analysis of DNA fragments amplified by PCR. Metabolites and proteins have been mainly separated using capillary zone electrophoresis (CZE using UV and MS detection. Electrophoretic chips have also proven their ability in the analysis of transgenic cultivars and a section describing the new applications is also included.

  9. Characterization of biological macromolecules by electrophoresis and neutron activation

    International Nuclear Information System (INIS)

    Stone, S.F.; Hancock, D.; Zeisler, R.

    1987-01-01

    A procedure combining polyacrylamide gel electrophoresis (PAGE) with INAA and autoradiography was developed to study biological macromolecules and their associated trace elements. Results from the application of this method to several metalloproteins are presented. (author)

  10. Sensitive determination of neurotransmitters in urine by microchip electrophoresis with multiple-concentration approaches combining field-amplified and reversed-field stacking.

    Science.gov (United States)

    Zhang, Yan; Zhang, Yi; Wang, Guan; Chen, Wujuan; Li, Yi; Zhang, Yating; He, Pingang; Wang, Qingjiang

    2016-07-01

    Microchip electrophoresis (MCE) is particularly attractive as it provides high sensitivity and selectivity, short analysis time and low sample consumption. An on-line preconcentration strategy combining field-amplified stacking (FASS) and reversed-field stacking (RFS) was developed for efficient and sensitive analysis of neurotransmitters in real urine samples by MCE with laser induced fluorescence (LIF) detection. In this study, the multiple-preconcentration strategy greatly improves the sensitivity enhancement and surpass other conventional analytical methods for neurotransmitters detection. Under optimal conditions, the separation of three neurotransmitters (dopamine, norepinephrine and serotonin), was achieved within 3min with limits of detection (S/N=3) of 1.69, 2.35, and 2.73nM, respectively. The detection sensitivities were improved by 201-, 182-, and 292-fold enhancement, for the three neurotransmitters respectively. Other evaluation parameters such as linear correlation coefficients were considered as satisfactory. A real urine sample was analyzed with recoveries of 101.8-106.4%. The proposed FASS-RFS-MCE method was characterized in terms of precision, linearity, accuracy and successfully applied for rapid and sensitive determination of three neurotransmitters in human urine. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Quantification of DNA damage by single-cell electrophoresis

    International Nuclear Information System (INIS)

    Ikushima, Takaji

    1990-01-01

    A simple technique of micro-agarose gel electrophoresis has been developed to quantify DNA damage in individual cells. Cells are embedded in agarose gel on microscope slides, lysed by detergents and then electrophoresed for a short time under neutral or alkaline condition. In irradiated cells, DNA migrates from the nucleus toward the anode, displaying commet-like pattern by staining with DNA-specific fluorescence dye. DNA damage is evaluated by measuring the distance of DNA migration. The technique was applied for measuring DNA damage in single cells exposed to 60 Co γ-rays, or to KUR radiation in the presence or absence of 10 B-enriched boric acid. The enhanced production of double-stranded DNA breaks by 10 B(n,α) 7 Li reaction was demonstrated here. The significant increase in the length of DNA migration was observed in single cells exposed to such a low dose as 20 cGy after alkaline micro electrophoresis. (author)

  12. Nonequilibrium electrophoresis of an ion-selective microgranule for weak and moderate external electric fields

    Science.gov (United States)

    Frants, E. A.; Ganchenko, G. S.; Shelistov, V. S.; Amiroudine, S.; Demekhin, E. A.

    2018-02-01

    Electrokinetics and the movement of charge-selective micro-granules in an electrolyte solution under the influence of an external electric field are investigated theoretically. Straightforward perturbation analysis is applied to a thin electric double layer and a weak external field, while a numerical solution is used for moderate electric fields. The asymptotic solution enables the determination of the salt concentration, electric charge distribution, and electro-osmotic velocity fields. It may also be used to obtain a simple analytical formula for the electrophoretic velocity in the case of quasi-equilibrium electrophoresis (electrophoresis of the first kind). This formula differs from the famous Helmholtz-Smoluchowski relation, which applies to dielectric microparticles, but not to ion-selective granules. Numerical calculations are used to validate the derived formula for weak external electric fields, but for moderate fields, nonlinear effects lead to a significant increase in electrophoretic mobility and to a transition from quasi-equilibrium electrophoresis of the first kind to nonequilibrium electrophoresis of the second kind. Theoretical results are successfully compared with experimental data.

  13. Recent developments and applications of capillary and microchip electrophoresis in proteomic and peptidomic analyses

    Czech Academy of Sciences Publication Activity Database

    Štěpánová, Sille; Kašička, Václav

    2016-01-01

    Roč. 39, č. 1 (2016), s. 198-211 ISSN 1615-9306 R&D Projects: GA ČR(CZ) GA13-17224S; GA ČR(CZ) GA15-01948S Institutional support: RVO:61388963 Keywords : capillary electrophoresis * mass spectrometry * microchip electrophoresis * peptidomics * proteomics Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 2.557, year: 2016

  14. Leverage principle of retardation signal in titration of double protein via chip moving reaction boundary electrophoresis.

    Science.gov (United States)

    Zhang, Liu-Xia; Cao, Yi-Ren; Xiao, Hua; Liu, Xiao-Ping; Liu, Shao-Rong; Meng, Qing-Hua; Fan, Liu-Yin; Cao, Cheng-Xi

    2016-03-15

    In the present work we address a simple, rapid and quantitative analytical method for detection of different proteins present in biological samples. For this, we proposed the model of titration of double protein (TDP) and its relevant leverage theory relied on the retardation signal of chip moving reaction boundary electrophoresis (MRBE). The leverage principle showed that the product of the first protein content and its absolute retardation signal is equal to that of the second protein content and its absolute one. To manifest the model, we achieved theoretical self-evidence for the demonstration of the leverage principle at first. Then relevant experiments were conducted on the TDP-MRBE chip. The results revealed that (i) there was a leverage principle of retardation signal within the TDP of two pure proteins, and (ii) a lever also existed within these two complex protein samples, evidently demonstrating the validity of TDP model and leverage theory in MRBE chip. It was also showed that the proposed technique could provide a rapid and simple quantitative analysis of two protein samples in a mixture. Finally, we successfully applied the developed technique for the quantification of soymilk in adulterated infant formula. The TDP-MRBE opens up a new window for the detection of adulteration ratio of the poor food (milk) in blended high quality one. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Phylogenetic reconstruction of South American felids defined by protein electrophoresis.

    Science.gov (United States)

    Slattery, J P; Johnson, W E; Goldman, D; O'Brien, S J

    1994-09-01

    Phylogenetic associations among six closely related South American felid species were defined by changes in protein-encoding gene loci. We analyzed proteins isolated from skin fibroblasts using two-dimensional electrophoresis and allozymes extracted from blood cells. Genotypes were determined for multiple individuals of ocelot, margay, tigrina, Geoffroy's cat, kodkod, and pampas cat at 548 loci resolved by two-dimensional electrophoresis and 44 allozyme loci. Phenograms were constructed using the methods of Fitch-Margoliash and neighbor-joining on a matrix of Nei's unbiased genetic distances for all pairs of species. Results of a relative-rate test indicate changes in two-dimensional electrophoresis data are constant among all South American felids with respect to a hyena outgroup. Allelic frequencies were transformed to discrete character states for maximum parsimony analysis. Phylogenetic reconstruction indicates a major split occurred approximately 5-6 million years ago, leading to three groups within the ocelot lineage. The earliest divergence led to Leopardus tigrina, followed by a split between an ancestor of an unresolved trichotomy of three species (Oncifelis guigna, O. geoffroyi, and Lynchailuris colocolo) and a recent common ancestor of Leopardus pardalis and L. wiedii. The results suggest that modern South American felids are monophyletic and evolved rapidly after the formation of the Panama land bridge between North and South America.

  16. Evaluation of denaturing gradient gel electrophoresis (DGGE) used ...

    African Journals Online (AJOL)

    Denaturing gradient gel electrophoresis (DGGE) is a powerful method used to study structure of bacterial communities, without cultivation, based on the diversity of the genes coding for ribosomal RNA. However, the results are strongly dependent on the respective target region of the used primer systems. Therefore, three ...

  17. Monitoring of the microbial communities involved in the soy sauce manufacturing process by PCR-denaturing gradient gel electrophoresis.

    Science.gov (United States)

    Tanaka, Yasushi; Watanabe, Jun; Mogi, Yoshinobu

    2012-08-01

    Soy sauce is a traditional seasoning produced through the fermentation of soybeans and wheat using microbes. In this study, the microbial communities involved in the soy sauce manufacturing process were analyzed by PCR-Denaturing Gradient Gel Electrophoresis (PCR-DGGE). The bacterial DGGE profile indicated that the bacterial microbes in the koji were Weissella cibaria (Weissella confusa, Weissella kimchii, Weissella salipiscis, Lactobacillus fermentum, Lactobacillus plantarum, Lactobacillus iners, or Streptococcus thermophilus), Staphylococcus gallinarum (or Staphylococcus xylosus), and Staphylococcus kloosii. In addition to these bacteria, Tetragenococcus halophilus was also detected in the mash during lactic acid fermentation. The fungal DGGE profile indicated that the fungal microbes in the koji were not only Aspergillus oryzae but also several yeasts. In the mash, Zygosaccharomyces rouxii appeared in the early fermentation stage, Candida etchellsii (or Candida nodaensis) and Candida versatilis were detected at the middle fermentation stage, and Candida etchellsii was detected at the mature fermentation stage. These results suggest that the microbial communities present during the soy sauce manufacturing process change drastically throughout its production. This is the first report to reveal the microbial communities involved in the soy sauce manufacturing process using a culture-independent method. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.

  18. Two-dimensional polyacrylamide gel electrophoresis of intracellular proteins

    International Nuclear Information System (INIS)

    Ojima, N.; Sakamoto, T.; Yamashita, M.

    1996-01-01

    Since two-dimensional electrophoresis was established by O'Farrell for analysis of intracellular proteins of Escherichia coli, it has been applied to separation of proteins of animal cells and tissues, and especially to identification of stress proteins. Using this technique, proteins are separated by isoelectric focusing containing 8 m urea in the first dimension and by SDS-PAGE in the second dimension. The gels are stained with Coomassie Blue R-250 dye, followed by silver staining. In the case of radio-labeled proteins, the gels are dried and then autoradiographed. In order to identify a specific protein separated by two-dimensional electrophoresis, a technique determining the N-terminal amino acid sequence of the protein has been developed recently. After the proteins in the gel were electrotransferred to a polyvinylidene difluoride membrane, the membrane was stained for protein with Commassie Blue and a stained membrane fragment was applied to a protein sequencer. Our recent studies demonstrated that fish cells newly synthesized various proteins in response to heat shock, cold nd osmotic stresses. For example, when cellular proteins extracted from cold-treated rainbow trout cells were subjected to two-dimensional gel electrophoresis, the 70 kDa protein was found to be synthesized during the cold-treatment. N-Terminal sequence analysis showed that the cold-inducible protein was a homolog of mammalian valosin-containing protein and yeast cell division cycle gene product CDC48p. Furthermore, the sequence data were useful for preparing PCR primers and a rabbit antibody against a synthetic peptide to analyze a role for the protein in the function of trout cells and mechanisms for regulation

  19. Human lymphocyte polymorphisms detected by quantitative two-dimensional electrophoresis

    International Nuclear Information System (INIS)

    Goldman, D.; Merril, C.R.

    1983-01-01

    A survey of 186 soluble lymphocyte proteins for genetic polymorphism was carried out utilizing two-dimensional electrophoresis of 14 C-labeled phytohemagglutinin (PHA)-stimulated human lymphocyte proteins. Nineteen of these proteins exhibited positional variation consistent with independent genetic polymorphism in a primary sample of 28 individuals. Each of these polymorphisms was characterized by quantitative gene-dosage dependence insofar as the heterozygous phenotype expressed approximately 50% of each allelic gene product as was seen in homozygotes. Patterns observed were also identical in monozygotic twins, replicate samples, and replicate gels. The three expected phenotypes (two homozygotes and a heterozygote) were observed in each of 10 of these polymorphisms while the remaining nine had one of the homozygous classes absent. The presence of the three phenotypes, the demonstration of gene-dosage dependence, and our own and previous pedigree analysis of certain of these polymorphisms supports the genetic basis of these variants. Based on this data, the frequency of polymorphic loci for man is: P . 19/186 . .102, and the average heterozygosity is .024. This estimate is approximately 1/3 to 1/2 the rate of polymorphism previously estimated for man in other studies using one-dimensional electrophoresis of isozyme loci. The newly described polymorphisms and others which should be detectable in larger protein surveys with two-dimensional electrophoresis hold promise as genetic markers of the human genome for use in gene mapping and pedigree analyses

  20. Trapping and breaking of in vivo nicked DNA during pulsed-field gel electrophoresis

    Science.gov (United States)

    Khan, Sharik R.; Kuzminov, Andrei

    2013-01-01

    Pulsed field gel electrophoresis (PFGE) offers a high-resolution approach to quantify chromosomal fragmentation in bacteria, measured as percent of chromosomal DNA entering the gel. The degree of separation in PFG depends upon the size of DNA, as well as various conditions of electrophoresis, such as electric field strength (FS), time of electrophoresis, switch time and buffer composition. Here we describe a new parameter, the structural integrity of the sample DNA itself, that influences its migration through PFGs. We show that sub-chromosomal fragments containing both spontaneous and DNA damage-induced nicks are prone to breakage during PFGE. Such breakage at single strand interruptions results in artefactual decrease in molecular weight of linear DNA making accurate determination of the number of double strand breaks difficult. While breakage of nicked sub-chromosomal fragments is FS-independent, some high molecular weight sub-chromosomal fragments are also trapped within wells under the standard PFGE conditions. This trapping can be minimized by lowering the field strength and increasing the time of electrophoresis. We discuss how breakage of nicked DNA may be mechanistically linked to trapping. Our results suggest how to optimize conditions for PFGE when quantifying chromosomal fragmentation induced by DNA damage. PMID:23770235

  1. Device for Horizontal Zone Electrophoresis in Free Electrolyte

    CERN Document Server

    Priemyshev, A N; Bozhikov, G A; Alikov, B A; Salamatin, A V; Furyaev, T A; Maslov, O D; Milanov, M V; Dmitriev, S N

    2000-01-01

    With expansion of area of application of an electromigration method the necessity of modernization of installation for horizontal zone electrophoresis in free electrolyte has appeared. A number of the basic modules was essentially advanced, that has allowed considerably increase reliability and accuracy of received results. The device is completely automated.

  2. Evaluation of wheat by polyacrylamide gel electrophoresis | Shuaib ...

    African Journals Online (AJOL)

    ... polyacrylamide gel electrophoresis (SDS-PAGE). Electrophorogram for each variety were scored and presence or absence of each band noted and was entered in a binary data matrix. Based on the data of SDS-PAGE gels cluster analysis was performed to check the variations among varieties. The overall result shows ...

  3. Characterization of metal/humic acid systems by Capillary Electrophoresis

    NARCIS (Netherlands)

    Staden JJ van; Hoop MAGT van den; Cleven R; LAC

    2000-01-01

    Metal-humic acid systems have been characterised applying Capillary Electrophoresis (CE). Appropriate experimental conditions with respect to carrier electrolyte, pH range, salt concentration, humic acid concentration and the applied potential, have been optimised. The influence of multivalent metal

  4. Capillary electrophoresis in the analysis of biologically important thiols

    Czech Academy of Sciences Publication Activity Database

    Lačná, J.; Kubáň, Petr; Foret, František

    2017-01-01

    Roč. 38, č. 1 (2017), s. 203-222 ISSN 0173-0835 Institutional support: RVO:68081715 Keywords : biological thiols * capillary electrophoresis * clinical applications Subject RIV: CB - Analytical Chemistry, Separation OBOR OECD: Analytical chemistry Impact factor: 2.744, year: 2016

  5. Detection of human DNA polymorphisms with a simplified denaturing gradient gel electrophoresis technique.

    OpenAIRE

    Noll, W W; Collins, M

    1987-01-01

    Single base pair differences between otherwise identical DNA molecules can result in altered melting behavior detectable by denaturing gradient gel electrophoresis. We have developed a simplified procedure for using denaturing gradient gel electrophoresis to detect base pair changes in genomic DNA. Genomic DNA is digested with restriction enzymes and hybridized in solution to labeled single-stranded probe DNA. The excess probe is then hybridized to complementary phage M13 template DNA, and th...

  6. Capillary electrophoresis of heparin and other glycosaminoglycans using a polyamine running electrolyte

    Energy Technology Data Exchange (ETDEWEB)

    Loegel, Thomas N.; Trombley, John D.; Taylor, Richard T. [Department of Chemistry and Biochemistry, Miami University, Oxford, OH 45056 (United States); Danielson, Neil D., E-mail: danielnd@muohio.edu [Department of Chemistry and Biochemistry, Miami University, Oxford, OH 45056 (United States)

    2012-11-13

    Highlights: Black-Right-Pointing-Pointer Ethylenediamine is likely acting as an ion-pairing agent. Black-Right-Pointing-Pointer Oversulfated chondroitin sulfate is last peak instead of first peak. Black-Right-Pointing-Pointer There is about a factor of five improved detectability with a 12.5 min analysis time. Black-Right-Pointing-Pointer Use of a 50 {mu}m ID capillary is possible. - Abstract: This study involves the use of polyamines as potential resolving agents for the capillary electrophoresis (CE) of glycosaminoglycans (GAGs), specifically heparin, dermatan sulfate, chondroitin sulfate, over-sulfated chondroitin sulfate (OSCS), and hyaluronan. All of the compounds can be separated from each other with the exception of chondroitin sulfate and hyaluronan. Using optimization software, the final run conditions are found to be 200 mM ethylenediamine and 45.5 mM phosphate as the electrolyte with -14 V applied across a 50 {mu}m ID Multiplication-Sign 24.5 cm fused silica capillary at 15 Degree-Sign C. The ion migration order, with OSCS as the last instead of the first peak, is in contrast to previous reports using either a high molarity TRIS or lithium phosphate run buffer with narrower bore capillaries. Total analysis time is 12. 5 min and the relative standard deviation of the heparin migration time is about 2.5% (n = 5). The interaction mechanism between selected polyamines and heparin is explored using conductivity measurements in addition to CE experiments to show that an ion-pairing mechanism is likely.

  7. Capillary electrophoresis-based assessment of nanobody affinity and purity

    NARCIS (Netherlands)

    Haselberg, Rob; Oliveira, Sabrina; van der Meel, Roy; Somsen, Govert W; de Jong, Gerhardus J

    2014-01-01

    Drug purity and affinity are essential attributes during development and production of therapeutic proteins. In this work, capillary electrophoresis (CE) was used to determine both the affinity and composition of the biotechnologically produced "nanobody" EGa1, the binding fragment of a

  8. Pulsed-field gel electrophoresis typing of Staphylococcus aureus isolates

    Science.gov (United States)

    Pulsed-field gel electrophoresis (PFGE) is the most applied and effective genetic typing method for epidemiological studies and investigation of foodborne outbreaks caused by different pathogens, including Staphylococcus aureus. The technique relies on analysis of large DNA fragments generated by th...

  9. DNA migration mechanism analyses for applications in capillary and microchip electrophoresis

    Science.gov (United States)

    Forster, Ryan E.; Hert, Daniel G.; Chiesl, Thomas N.; Fredlake, Christopher P.; Barron, Annelise E.

    2009-01-01

    In 2009, electrophoretically driven DNA separations in slab gels and capillaries have the sepia tones of an old-fashioned technology in the eyes of many, even while they remain ubiquitously used, fill a unique niche, and arguably have yet to reach their full potential. For comic relief, what is old becomes new again: agarose slab gel separations are used to prepare DNA samples for “next-gen” sequencing platforms (e.g., the Illumina and 454 machines)—dsDNA molecules within a certain size range are “cut out” of a gel and recovered for subsequent “massively parallel” pyrosequencing. In this review, we give a Barron lab perspective on how our comprehension of DNA migration mechanisms in electrophoresis has evolved, since the first reports of DNA separations by CE (∼1989) until now, 20 years later. Fused silica capillaries, and borosilicate glass and plastic microchips, quietly offer increasing capacities for fast (and even “ultra-fast”), efficient DNA separations. While the channel-by-channel scaling of both old and new electrophoresis platforms provides key flexibility, it requires each unique DNA sample to be prepared in its own micro- or nanovolume. This Achille's heel of electrophoresis technologies left an opening through which pooled-sample, next-gen DNA sequencing technologies rushed. We shall see, over time, whether sharpening understanding of transitions in DNA migration modes in crosslinked gels, nanogel solutions, and uncrosslinked polymer solutions will allow electrophoretic DNA analysis technologies to flower again. Microchannel electrophoresis, after a quiet period of metamorphosis, may emerge sleeker and more powerful, to claim its own important niche applications. PMID:19582705

  10. Development of a high-quality cut-off wall using electrophoresis

    International Nuclear Information System (INIS)

    Kawachi, T.; Murahashi, H.

    1991-01-01

    Techniques to build a high-quality cut-off wall have been developed for storage facilities of low-level radioactive waste (LLW) as an emergency measures to prevent leakages. The cut-off wall is highly impermeable, nucleid-adsorptive and have long-term durability. Electrophoresis is used to form impermeable membrane of bentonite as main features of the cut-off wall. First of all, laboratory tests have been conducted to study ways of building barriers on site and to collect data on the barriers properties. Afterwards, on-site construction tests of a high-quality cut-off wall have been carried out. In this paper, we describe the process and results on the studies of the high-quality cut-off wall using electrophoresis

  11. Simultaneous determination of five flavonoids in saussurea involucrata by capillary electrophoresis

    International Nuclear Information System (INIS)

    Li, Y.; Zhong, H.; Zhong, H.

    2013-01-01

    A method of determination of five flavonoids in Saussurea involucrata by beta-cyclodextrin modified capillary zone electrophoresis has been developed.The effects of buffer pH and buffer concentration, applied voltage and beta-CD concentrations on the separation were systematically investigated. The optimum condition providing baseline separation of all compounds within 8 min was obtained in the 20 mmol per liter borax buffer (pH 9.2), 20 kV applied voltage and 8 mmol per liter beta-CD. The linearity, detection limits, limits of quantification, reproducibility and recovery were satisfactory. The beta-cyclodextrin modified capillary zone electrophoresis method proposed here has been satisfactorily employed to analyze S. involucrate samples. (author)

  12. Distribution of hemoglobinopathies in patients presenting for electrophoresis and comparison of result with High performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    R Jha

    2015-09-01

    Full Text Available Background: Nearly 226 million carriers of thalassemias and abnormal hemoglobin are present worldwide according to the World Health Organization (WHO. The laboratory plays an important role in the investigation of the thalassemias and hemoglobinopathies. Cellulose acetate electrophoresis at alkaline pH and diagnosis based mainly on visual impression of thickness of band may miss the thalassemic trait patients. The aim of this study was to find out different hemoglobinopathies and thalassemia presenting in our hospital and to compare electrophoresis results with HPLC.Materials and Methods: This study was performed in the hematopathology section of Department of Pathology of Tribhuvan University Teaching Hospital on cases sent for electrophoresis during 18 months period from October 2013 to March 2015 and included hemoglobinopathies and thalassemias identified by either electrophoresis or HPLC. 97 cases fulfilled the inclusion criteria and thus were included in the study. Electrophoresis at alkaline pH was done in all whereas HPLC was performed in 27 cases.Results: A sharp peak of hemoglobinopathies and thalassemias was seen in Tharu community though other communities are also affected. Thalassemia trait was the most common diagnosis (26.8% followed by sickle cell anemia (21.6%.  Electrophoresis was efficient in detecting some alpha thalassemia variants but missed many cases of beta thalassemia trait.Conclusion: Beta Thalassemia trait and sickle cell anemia both are common in Nepal , along with some other hemoglobinopathies  A sharp peak of hemoglobinopathies and thalassemias are seen in Tharu community. These abnormal hemoglobins and thalassemias are mainly seen in Terai region. Electrophoresis fails to quantify hemoglobin percentage and thus is not appropriate test in beta thalassemia screening. 

  13. Comparative Studies of Two-Dimensional Electrophoresis on Galactosidase Relating to Bombyx Lectin Activity

    OpenAIRE

    加藤, 靖夫; カトウ, ヤスオ; Yasuo, Kato

    2005-01-01

    "Comparative two-dimensional polyacrylamide gel electrophoresis (2-D PAGE) analysis on the haemolymph of the domesticated silkworm, Bombyx mori and Fraction II obtained by gel filtration from the haemolymph of B. mori was performed using the 2-D mini-slab system (Atto Co.) (the first method of 2-D PAGE) and the Mini-PROTEAN mini tube gel 2-D PAGE system (Bio-Rad Laboratories, Inc.) (the second method). Moreover, two-dimensionnal electrophoresis analysis on standard β-galactosidase, grade III ...

  14. A critical overview of non-aqueous capillary electrophoresis. Part II: separation efficiency and analysis time.

    Science.gov (United States)

    Kenndler, Ernst

    2014-03-28

    plate height (and the plate number) obtainable under limiting conditions (at zero ionic strength) has the same ultimate value for all solvents. However, in background electrolytes with finite ionic strength, the maximum reachable plate number depends on the solvent, and in water it is higher than in the most commonly used organic solvents: methanol and acetonitrile. Thermal peak broadening is also larger in the organic solvents if compared to aqueous solutions under comparable conditions. However, its influence on the plate height is negligible under conditions established with commercial instrumentation. From the laws of electric and thermal conductance, it follows that no general conclusion can be drawn that with organic solvents higher field strength can be applied and shorter analysis time can be reached; the contrary is more evident: under comparable conditions aqueous solutions lead to more favorable results. This comprehensive analysis provides strong evidence that the broadly held notion of non-aqueous CZE being principally superior to aqueous CZE is a myth rather than a fact. However, several studies in which the employment of non-aqueous conditions has been instrumental to solve challenging analytical problems demonstrate that the intelligent use of non-aqueous CE has and will continue having its place in modern separation science. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Affinity Electrophoresis for Analysis of Catalytic Module-Carbohydrate Interactions

    DEFF Research Database (Denmark)

    Cockburn, Darrell; Wilkens, Casper; Svensson, Birte

    2017-01-01

    Affinity electrophoresis has long been used to study the interaction between proteins and large soluble ligands. The technique has been found to have great utility for the examination of polysaccharide binding by proteins, particularly carbohydrate binding modules (CBMs). In recent years, carbohy...

  16. Capillary electrophoresis microchip coupled with on-line chemiluminescence detection

    International Nuclear Information System (INIS)

    Su Rongguo; Lin Jinming; Qu Feng; Chen Zhifeng; Gao Yunhua; Yamada, Masaaki

    2004-01-01

    In the present work, chemiluminescence detection was integrated with capillary electrophoresis microchip. The microchip was designed on the principle of flow-injection chemiluminescence system and capillary electrophoresis. It has three main channels, five reservoirs and a detection cell. As model samples, dopamine and catechol were separated and detected using a permanganate chemiluminescent system on the prepared microchip. The samples were electrokinetically injected into the double-T cross section, separated in the separation channel, and then oxidized by chemiluminescent reagent delivered by a home-made micropump to produce light in the detection cell. The electroosmotic flow could be smoothly coupled with the micropump flow. The detection limits for dopamine and catechol were 20.0 and 10.0 μM, respectively. Successful separation and detection of dopamine and catechol demonstrated the distinct advantages of integration of chemiluminescent detection on a microchip for rapid and sensitive analysis

  17. An improved interface for capillary zone electrophoresis-mass spectrometry

    International Nuclear Information System (INIS)

    Smith, R.D.; Loo, J.A.; Barinaga, C.J.; Udseth, H.R.

    1988-06-01

    We have recently developed an improved electrospray ionization interface for capillary electrophoresis mass-spectrometry (CZE-MS). Our initial interface employed a vacuum deposited metal film at the exit of the capillary to make an electrical contact with he eluting buffer and establish the electrospray field gradient. This interface did, however, impose significant limitations on the range of capillary electrophoretic (CE) separations that could be performed. To circumvent these limitations, an interface that does not require a metalized tip was designed nd developed. In the new approach, the electrical contact at the column exit is made through a flowing liquid sheath. The principal advantage of this interface is that it allows operation with a much broader range of electrophoresis conditions. The sheath flow can be readily varied in both composition and volume. An electrospray ionization spectrum is given for a previously intractable buffer solution. 5 refs., 2 figs

  18. Automatic DNA Diagnosis for 1D Gel Electrophoresis Images using Bio-image Processing Technique.

    Science.gov (United States)

    Intarapanich, Apichart; Kaewkamnerd, Saowaluck; Shaw, Philip J; Ukosakit, Kittipat; Tragoonrung, Somvong; Tongsima, Sissades

    2015-01-01

    DNA gel electrophoresis is a molecular biology technique for separating different sizes of DNA fragments. Applications of DNA gel electrophoresis include DNA fingerprinting (genetic diagnosis), size estimation of DNA, and DNA separation for Southern blotting. Accurate interpretation of DNA banding patterns from electrophoretic images can be laborious and error prone when a large number of bands are interrogated manually. Although many bio-imaging techniques have been proposed, none of them can fully automate the typing of DNA owing to the complexities of migration patterns typically obtained. We developed an image-processing tool that automatically calls genotypes from DNA gel electrophoresis images. The image processing workflow comprises three main steps: 1) lane segmentation, 2) extraction of DNA bands and 3) band genotyping classification. The tool was originally intended to facilitate large-scale genotyping analysis of sugarcane cultivars. We tested the proposed tool on 10 gel images (433 cultivars) obtained from polyacrylamide gel electrophoresis (PAGE) of PCR amplicons for detecting intron length polymorphisms (ILP) on one locus of the sugarcanes. These gel images demonstrated many challenges in automated lane/band segmentation in image processing including lane distortion, band deformity, high degree of noise in the background, and bands that are very close together (doublets). Using the proposed bio-imaging workflow, lanes and DNA bands contained within are properly segmented, even for adjacent bands with aberrant migration that cannot be separated by conventional techniques. The software, called GELect, automatically performs genotype calling on each lane by comparing with an all-banding reference, which was created by clustering the existing bands into the non-redundant set of reference bands. The automated genotype calling results were verified by independent manual typing by molecular biologists. This work presents an automated genotyping tool from DNA

  19. Automatic DNA Diagnosis for 1D Gel Electrophoresis Images using Bio-image Processing Technique

    Science.gov (United States)

    2015-01-01

    Background DNA gel electrophoresis is a molecular biology technique for separating different sizes of DNA fragments. Applications of DNA gel electrophoresis include DNA fingerprinting (genetic diagnosis), size estimation of DNA, and DNA separation for Southern blotting. Accurate interpretation of DNA banding patterns from electrophoretic images can be laborious and error prone when a large number of bands are interrogated manually. Although many bio-imaging techniques have been proposed, none of them can fully automate the typing of DNA owing to the complexities of migration patterns typically obtained. Results We developed an image-processing tool that automatically calls genotypes from DNA gel electrophoresis images. The image processing workflow comprises three main steps: 1) lane segmentation, 2) extraction of DNA bands and 3) band genotyping classification. The tool was originally intended to facilitate large-scale genotyping analysis of sugarcane cultivars. We tested the proposed tool on 10 gel images (433 cultivars) obtained from polyacrylamide gel electrophoresis (PAGE) of PCR amplicons for detecting intron length polymorphisms (ILP) on one locus of the sugarcanes. These gel images demonstrated many challenges in automated lane/band segmentation in image processing including lane distortion, band deformity, high degree of noise in the background, and bands that are very close together (doublets). Using the proposed bio-imaging workflow, lanes and DNA bands contained within are properly segmented, even for adjacent bands with aberrant migration that cannot be separated by conventional techniques. The software, called GELect, automatically performs genotype calling on each lane by comparing with an all-banding reference, which was created by clustering the existing bands into the non-redundant set of reference bands. The automated genotype calling results were verified by independent manual typing by molecular biologists. Conclusions This work presents an

  20. Analysis of lipoproteins by capillary zone electrophoresis in microfluidic devices: Assay development and surface roughness measurements

    NARCIS (Netherlands)

    Weiller, Bruce H.; Ceriotti, Laura; Shibata, Takayuki; Rein, Dietrich; Roberts, Matthew A.; Lichtenberg, Jan; German, J. Bruce; De Rooij, Nico F.; Verpoorte, Elisabeth

    2002-01-01

    The development of a new assay for lipoproteins by capillary electrophoresis in fused-silica capillaries and in glass microdevices is described in this paper. The separation of low-density (LDL) and high-density (HDL) lipoproteins by capillary zone electrophoresis is demonstrated in fused-silica

  1. Diamond cubic phase of monoolein and water as an amphiphilic matrix for electrophoresis of oligonucleotides.

    Science.gov (United States)

    Carlsson, Nils; Winge, Ann-Sofie; Engström, Sven; Akerman, Björn

    2005-10-06

    We used a cubic liquid crystal formed by the nonionic monoglyceride monoolein and water as a porous matrix for the electrophoresis of oligonucleotides. The diamond cubic phase is thermodynamically stable when in contact with a water-rich phase, which we exploit to run the electrophoresis in the useful submarine mode. Oligonucleotides are separated according to size and secondary structure by migration through the space-filling aqueous nanometer pores of the regular liquid crystal, but the comparatively slow migration means the cubic phase will not be a replacement for the conventional DNA gels. However, our demonstration that the cubic phase can be used in submarine electrophoresis opens up the possibility for a new matrix for electrophoresis of amphiphilic molecules. From this perspective, the results on the oligonucleotides show that water-soluble particles of nanometer size, typical for the hydrophilic parts of membrane-bound proteins, may be a useful separation motif. A charged contamination in the commercial sample of monoolein, most likely oleic acid that arises from its hydrolysis, restricts useful buffer conditions to a pH below 5.6.

  2. Cationic polyelectrolyte functionalized magnetic particles assisted highly sensitive pathogens detection in combination with polymerase chain reaction and capillary electrophoresis.

    Science.gov (United States)

    Chen, Jia; Lin, Yuexin; Wang, Yu; Jia, Li

    2015-06-01

    Pathogenic bacteria cause significant morbidity and mortality to humans. There is a pressing need to establish a simple and reliable method to detect them. Herein, we show that magnetic particles (MPs) can be functionalized by poly(diallyl dimethylammonium chloride) (PDDA), and the particles (PDDA-MPs) can be utilized as adsorbents for capture of pathogenic bacteria from aqueous solution based on electrostatic interaction. The as-prepared PDDA-MPs were characterized by Fourier-transform infrared spectroscopy, zeta potential, vibrating sample magnetometry, X-ray diffraction spectrometry, scanning electron microscopy, and transmission electron microscopy. The adsorption equilibrium time can be achieved in 3min. According to the Langmuir adsorption isotherm, the maximum adsorption capacities for E. coli O157:H7 (Gram-negative bacteria) and L. monocytogenes (Gram-positive bacteria) were calculated to be 1.8×10(9) and 3.1×10(9)cfumg(-1), respectively. The bacteria in spiked mineral water (1000mL) can be completely captured when applying 50mg of PDDA-MPs and an adsorption time of 5min. In addition, PDDA-MPs-based magnetic separation method in combination with polymerase chain reaction and capillary electrophoresis allows for rapid detection of 10(1)cfumL(-1) bacteria. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Application of the denaturing gradient gel electrophoresis (DGGE) technique as an efficient diagnostic tool for ciliate communities in soil.

    Science.gov (United States)

    Jousset, Alexandre; Lara, Enrique; Nikolausz, Marcell; Harms, Hauke; Chatzinotas, Antonis

    2010-02-01

    Ciliates (or Ciliophora) are ubiquitous organisms which can be widely used as bioindicators in ecosystems exposed to anthropogenic and industrial influences. The evaluation of the environmental impact on soil ciliate communities with methods relying on morphology-based identification may be hampered by the large number of samples usually required for a statistically supported, reliable conclusion. Cultivation-independent molecular-biological diagnostic tools are a promising alternative to greatly simplify and accelerate such studies. In this present work a ciliate-specific fingerprint method based on the amplification of a phylogenetic marker gene (i.e. the 18S ribosomal RNA gene) with subsequent analysis by denaturing gradient gel electrophoresis (DGGE) was developed and used to monitor community shifts in a polycyclic aromatic hydrocarbon (PAH) polluted soil. The semi-nested approach generated ciliate-specific amplification products from all soil samples and allowed to distinguish community profiles from a PAH-polluted and a non-polluted control soil. Subsequent sequence analysis of excised bands provided evidence that polluted soil samples are dominated by organisms belonging to the class Colpodea. The general DGGE approach presented in this study might thus in principle serve as a fast and reproducible diagnostic tool, complementing and facilitating future ecological and ecotoxicological monitoring of ciliates in polluted habitats. Copyright 2009 Elsevier B.V. All rights reserved.

  4. Determination of D-saccharic acid-1,4-lactone from brewed kombucha broth by high-performance capillary electrophoresis.

    Science.gov (United States)

    Wang, Kan; Gan, Xuhua; Tang, Xinyun; Wang, Shuo; Tan, Huarong

    2010-02-01

    Kombucha is a health tonic. D-saccharic acid-1,4-lactone (DSL), a component of kombucha, inhibits the activity of glucuronidase, an enzyme indirectly related with cancers. To date, there is no efficient method to determine the content of DSL in kombucha samples. In this paper, we report a rapid and simple method for the separation and determination of DSL in kombucha samples, using the high-performance capillary electrophoresis (HPCE) method with diode array detection (DAD). With optimized conditions, DSL can be separated in a 50 cm length capillary at a separation voltage of 20 kV in 40 mmol/L borax buffer (pH 6.5) containing 30 mmol/L SDS and 15% methanol (v/v). Quantitative evaluation of DSL was determined by ultraviolet absorption at lambda=190 nm. The relationship between the peak areas and the DSL concentrations, in a specified working range with linear response, was determined by first-order polynomial regression over the range 50-1500 microg/mL with a detection limit of 17.5 microg/mL. Our method demonstrated excellent reproducibility and accuracy with relative standard deviations (RSD) of less than 5% DSL content (n=5). This is the first report to determine DSL by HPCE. We have successfully applied this method to determine DSL in kombucha samples in various fermented conditions. 2009 Elsevier B.V. All rights reserved.

  5. Exploring chip-capillary electrophoresis-laser-induced fluorescence field-deployable platform flexibility: Separations of fluorescent dyes by chip-based non-aqueous capillary electrophoresis

    Czech Academy of Sciences Publication Activity Database

    Nuchtavorn, N.; Smejkal, Petr; Breadmore, M. C.; Guijt, R. M.; Doble, P.; Bek, F.; Foret, František; Suntornsuk, L.; Macka, M.

    2013-01-01

    Roč. 1286, APR (2013), s. 216-221 ISSN 0021-9673 R&D Projects: GA ČR(CZ) GBP206/12/G014 Institutional support: RVO:68081715 Keywords : microfluidic chip CE * capillary electrophoresis * NACE * LIF detection Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 4.258, year: 2013

  6. Improved protocol for isolation of Campylobacter spp. from retail broiler meat and use of pulsed field gel electrophoresis for the typing of isolates.

    Science.gov (United States)

    Oyarzabal, Omar A; Williams, Aretha; Zhou, Ping; Samadpour, Mansour

    2013-10-01

    To improve the detection of Campylobacter spp. in retail broiler meat, a reference method (R subsamples) based on the enrichment of 25 g of meat in Bolton broth at 42°C under microaerobiosis was compared with an alternative method (A subsamples) consisting in the rinsing of meat samples for 30s in buffered peptone water with antimicrobials with incubation at 42°C under aerobiosis. One piece of meat (breasts, tenderloins and thighs) was rinse in experiment 1 (A1) and two pieces in experiment 2 (A2). Campylobacter spp. were isolated on agar plates and identified by PCR. Retail samples in Alabama had less prevalence (P ≤ 0.05) than samples in the state of Washington. The percentage of positive was higher (P ≤ 0.05) in A than in R subsamples and rinsing two pieces of meat yielded the highest percentage of positive subsamples. R subsamples showed variations in the prevalence by product. However, A subsamples had similar prevalence of positives among products compare to the result from reference method. More Campylobacter coli isolates were collected in A2 subsamples. Pulse field gel electrophoresis (PFGE) was used as subtyping method to study the genome similarity among the isolates from all methods. A larger diversity of isolates were detected by PFGE in A2 subsamples. Denaturing gradient gel electrophoresis analysis suggested that the initial bacterial populations of the meat samples impact the final bacterial profile after enrichment. Rinsing broiler meats was less time consuming, required less sample preparation and was more sensitive than the reference method for the isolation of naturally occurring Campylobacter spp. This new method could help with epidemiological and intervention studies to control Campylobacter spp. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Performance comparison of capillary and agarose gel electrophoresis for the identification and characterization of monoclonal immunoglobulins.

    Science.gov (United States)

    McCudden, Christopher R; Mathews, Stephanie P; Hainsworth, Shirley A; Chapman, John F; Hammett-Stabler, Catherine A; Willis, Monte S; Grenache, David G

    2008-03-01

    The objective of this study was to compare gel- and capillary-based serum protein electrophoresis methods to identify and characterize monoclonal immunoglobulins (M proteins). Five reviewers interpreted 149 consecutively ordered serum specimens following agarose gel electrophoresis (AGE), capillary electrophoresis (CE), immunofixation electrophoresis (IFE), and subtraction immunotyping (IT). As a screening test for detecting M proteins, AGE and CE displayed similar sensitivity (91% and 92%, respectively). CE was less specific (74%) than AGE (81%). An analysis of interinterpreter agreement revealed that interpretations were more consistent using gel-based methods than capillary-based methods, with 80% of the gel interpretations being in complete (5/5) agreement compared with 67% of the capillary interpretations. After implementing the capillary-based methods, the number of tests per reportable result increased (from 1.58 to 1.73). CE is an analytically suitable alternative to AGE, but laboratories implementing it will need to continue IFE testing to characterize all M proteins detected by CE.

  8. Investigation of endogenous soybean food allergens by using a 2-dimensional gel electrophoresis approach.

    Science.gov (United States)

    Rouquié, David; Capt, Annabelle; Eby, William H; Sekar, Vaithilingam; Hérouet-Guicheney, Corinne

    2010-12-01

    As part of the safety assessment of genetically modified (GM) soybean, 2-dimensional gel electrophoresis analyses were performed with the isoxaflutole and glyphosate tolerant soybean FG72, its non-GM near-isogenic counterpart (Jack) and three commercial non-GM soybean lines. The objective was to compare the known endogenous human food allergens in seeds in the five different soybean lines in order to evaluate any potential unintended effect(s) of the genetic modification. In total, 37 protein spots representing five well known soybean food allergen groups were quantified in each genotype. Qualitatively, all the allergenic proteins were detected in the different genetic backgrounds. Quantitatively, among 37 protein spots, the levels of accumulation of three allergens were slightly lower in the GM soybean than in the non-GM counterparts. Specifically, while the levels of two of these three allergens fell within the normal range of variation observed in the four non-GM varieties, the level of the third allergen was slightly below the normal range. Overall, there was no significant increase in the level of allergens in FG72 soybean seeds. Therefore, the FG72 soybean can be considered as safe as its non-GM counterpart with regards to endogenous allergenicity. Additional research is needed to evaluate the biological variability in the levels of endogenous soybean allergens and the correlation between level of allergens and allergenic potential in order to improve the interpretation of these data in the safety assessment of GM soybean context. Copyright © 2010 Elsevier Inc. All rights reserved.

  9. Two-dimensional gel electrophoresis analysis of different parts of ...

    African Journals Online (AJOL)

    Two-dimensional gel electrophoresis analysis of different parts of Panax quinquefolius L. root. ... From these results it was concluded that proteomic analysis method was an effective way to identify the different parts of quinquefolius L. root. These findings may contribute to further understanding of the physiological ...

  10. Ultrasensitive and accelerated detection of ciguatoxin by capillary electrophoresis via on-line sandwich immunoassay with rotating magnetic field and nanoparticles signal enhancement.

    Science.gov (United States)

    Zhang, Zhaoxiang; Zhang, Chaoying; Luan, Wenxiu; Li, Xiufeng; Liu, Ying; Luo, Xiliang

    2015-08-12

    A sensitive and rapid on-line immunoassay for the determination of ciguatoxin CTX3C was developed based on a capillary mixing system, which was integrated with capillary electrophoresis (CE) separation and electrochemical (EC) detection. In the sandwich immunoassay system, anti-CTX3C-functionalized magnetic nanoparticles were used as immunosensing probes, and horseradish peroxidase (HRP) and anti-CTX3C antibody were bound onto the surface of gold nanoparticles (AuNPs) and used as recognition elements. Online formation of immunocomplex was realized in capillary inlet end with an external rotating magnetic field. Compared with classical HPLC-MS and ELISA, the assay adopting AuNPs as multienzyme carriers and online sandwich immunoassay format with rotating magnetic field exhibited higher sensitivity and shorter assay time. The linear range of the assay for CTX3C was from 0.6 to 150 ng/L with a correlation coefficient of 0.9948 (n = 2), and the detection limit (S/N = 3) was 0.09 ng/L. The developed assay showed satisfying reproducibility and stability, and it was successfully applied for the quantification of CTX3C in fish samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Canine serum protein patterns using high-resolution electrophoresis (HRE).

    Science.gov (United States)

    Abate, O; Zanatta, R; Malisano, T; Dotta, U

    2000-03-01

    Serum protein values were determined in 26 healthy dogs using agarose gel electrophoresis (SPE), splitting the electrophoretic separation into six regions: albumin, alpha(1), alpha(2), beta(1), beta(2)and gamma globulins. High-resolution electrophoresis (HRE) was used to separate single proteins. Serum proteins from dogs (26 healthy and 20 affected by various diseases) were then characterized by electrophoretic immunofixation (IFE) and Sudan black staining on HRE film. Haemoglobin and normal canine plasma and serum were used to identify haptoglobin and fibrinogen, respectively. In the standard pattern, determined by HRE, the following proteins were identified: albumin, alpha(1)-lipoprotein (alpha(1)-region), haptoglobin and alpha(2)-macroglobulin (alpha(2)-region), beta -lipoprotein and C3 (beta(1)-region), transferrin and IgM (beta(2)-region), IgG (mostly in gamma -region and partly in beta(2)-region). The HRE pattern shown by healthy dogs could be compared with those of dogs affected by various diseases to obtain clinical information. Copyright 2000 Harcourt Publishers Ltd.

  12. Optically controlled electrophoresis with a photoconductive substrate

    Science.gov (United States)

    Inami, Wataru; Nagashima, Taiki; Kawata, Yoshimasa

    2018-05-01

    A photoconductive substrate is used to perform electrophoresis. Light-induced micro-particle flow manipulation is demonstrated without using a fabricated flow channel. The path along which the particles were moved was formed by an illuminated light pattern on the substrate. Because the substrate conductivity and electric field distribution can be modified by light illumination, the forces acting on the particles can be controlled. This technique has potential applications as a high functionality analytical device.

  13. VIII All-Russian symposium on molecular liquid chromatography and capillary electrophoresis. Program. Summary of reports

    International Nuclear Information System (INIS)

    2001-01-01

    Program and summary of reports of the VIII All-Russian symposium on molecular liquid chromatography and capillary electrophoresis are performed. The meeting took place 15-19 October, 2001 in Moscow. Many problems of liquid and ion exchange chromatography, capillary electrophoresis, thin-layer chromatography have been discussed extensively. Reports covering properties of sorbents and devices for chromatography are incorporated in the collection [ru

  14. Technical improvement to prevent DNA degradation of Leptospira spp. in pulsed field gel electrophoresis.

    Science.gov (United States)

    Ribeiro, R L; Machry, L; Brazil, J M V; Ramos, T M V; Avelar, K E S; Pereira, M M

    2009-08-01

    Leptospirosis is a public health problem. Infection with pathogenic Leptospira occurs by exposure to many environments and is traditionally associated with occupational risk activities. Pulsed-field gel electrophoresis was used to investigate the epidemiological relatedness among Leptospira isolates. However, analysis by PFGE yielded inconclusive data as a result of extensive DNA degradation. This degradation can be significantly reduced by the inclusion of thiourea in the electrophoresis buffer, improving the analysis of DNA banding patterns.

  15. Use of electrophoresis and immunoelectrophoresis in taxonomic and pollution studies

    Digital Repository Service at National Institute of Oceanography (India)

    Menezes, M.R.; Qasim, S.Z.

    Studies were conducted on the electrophoresis of blood serum and eye lens proteins of 5 fishes and immunoelectrophoresis of the soluble lens proteins of 10 fishes. The effects of a toxic pollutant (mercury) on the electrophoretic patterns...

  16. Application of a diode-array detector in capillary electrophoresis

    NARCIS (Netherlands)

    Beck, W.; Hoek, van R.; Engelhardt, H.

    1993-01-01

    In the last decade diode-array detection has proved to be extremely useful in high performance liquid chromatography in recording UV-visible spectra directly and on-line in the column effluent. In capillary electrophoresis (CE) only fast-scanning detectors with long scan times (up to 2 s) are

  17. The single-cell gel electrophoresis assay to determine apoptosis ...

    African Journals Online (AJOL)

    When the frequency of appearance of apoptotic cells following was observed over a period of time, there was a significant increase in appearance of apoptosis when using single cell gel electrophoresis assay. The present report demonstrates that the characteristic pattern of apoptotic comets detected by the comet assay ...

  18. New analytical portable instrument for microchip electrophoresis with electrochemical detection.

    Science.gov (United States)

    Fernández-la-Villa, Ana; Pozo-Ayuso, Diego F; Castaño-Alvarez, Mario

    2010-08-01

    A new portable instrument that includes a high voltage power supply, a bipotentiostat, and a chip holder has been especially developed for using microchips electrophoresis with electrochemical detection. The main unit of the instrument has dimensions of 150 x 165 x 70 mm (wxdxh) and consists of a four-outputs high voltage power supply with a maximum voltage of +/-3 KV and an acquisition system with two channels for dual amperometric (DC or pulsed amperometric detection) detection. Electrochemical detection has been selected as signal transduction method because it is relatively easily implemented, since nonoptical elements are required. The system uses a lithium-ion polymer battery and it is controlled from a desktop or laptop PC with a graphical user interface based on LabVIEW connected by serial RS232 or Bluetooth. The last part of the system consists of a reusable chip holder for housing the microchips, which contain all the electrical connections and reservoirs for making the work with microchips easy. The performance of the new instrument has been evaluated and compared with other commercially available apparatus using single- and dual-channel pyrex microchips for the separation of the neurotransmitters dopamine, epinephrine, and 3,4-dihydroxy-L-phenyl-alanine. The reduction of the size of the instrument has not affected the good performance of the separation and detection using microchips electrophoresis with electrochemical detection. Moreover, the new portable instrument paves the way for in situ analysis making the use of microchips electrophoresis easier.

  19. Optimization of a pulsed-field gel electrophoresis for molecular typing of Proteus mirabilis

    Directory of Open Access Journals (Sweden)

    Alper Karagöz

    2013-09-01

    Full Text Available Objective: For the detection of outbreaks caused byProteus mirabilis, strains clonal relations are determinedmethods as “pulsed-field gel electrophoresis (PFGE”.The aim of this study was optimization of a pulsed-fieldgel electrophoresis for molecular typing of P. mirabilis.Methods: In this study, PFGE’ protocol is optimized foruse in molecular typing of P. mirabilis. Phylogenetic analyzesof strains were evaluated with Bionumerics softwaresystem (version 6.01; Applied Maths, Sint-Martens-Latem, Belgium.Results: This protocol compared with Gram-negativebacteria PFGE protocols, NotI enzyme is suitable for thisbacterium. Electrophoresis conditions should be revealedas; - block 1: initial pulse duration 1 sec, ending pulseduration 30 sec, striking angle 120°, the current 6 V/cm2,temperature 14°C, time 8 hours; - block 2: initial pulseduration 30 sec, ending pulse duration 70 sec, strikingangle 120°, the current 6 V/cm2, temperature 14°C, time16 hours; - TBE, pH=8.4.Conclusion: P. mirabilis strains were typed by PFGE andBionumerics analysis program were determined clonal relationships.The procedure was simple, reproducible andsuitable for these bacteria. Also it was evaluated, becauseof reducing time, the solution volumes and enzymes canbe economically. Outbreaks of nosocomial infections dueto bacteria studied assessment and the potential to provideuseful information about the degree of prevalence.This optimized protocol is allowed different centers’ PFGEresults to compare with other laboratories results. J ClinExp Invest 2013; 4 (3: 306-312Key words: Proteus mirabilis, molecular typing, pulsedfieldgel electrophoresis.

  20. Comparison of ethanol-soluble proteins from different rye (Secale cereale) varieties by two-dimensional electrophoresis

    DEFF Research Database (Denmark)

    Radzikowski, Louise; Nesic, Ljiljana; Hansen, H.B.

    2002-01-01

    The major storage proteins from six rye varieties, grown under the same conditions in 1997 and 1998 in Ronhave, Denmark, were analyzed by two-dimensional (2-D) polyacrylamide gel electrophoresis. The proteins were extracted from ground rye kernels with 70% ethanol and separated by 2-D electrophor......The major storage proteins from six rye varieties, grown under the same conditions in 1997 and 1998 in Ronhave, Denmark, were analyzed by two-dimensional (2-D) polyacrylamide gel electrophoresis. The proteins were extracted from ground rye kernels with 70% ethanol and separated by 2-D...... electrophoresis. The gels were scanned, compared using ImageMaster(R) software and the data sets were analyzed by principal component analysis (PCA) using THE UNSCRAMBLER software. Afterwards MATLAB was used to make a cluster analysis of the varieties based on PCA. The analysis of the gels showed...... separately. When the results were combined from the two years five varieties could be differentiated. The results from the PCA confirmed the finding of the unique spots and cluster analysis was made in order to illustrate the results. The combination of the results from 2-D electrophoresis and other grain...

  1. Blood grouping based on PCR methods and agarose gel electrophoresis.

    Science.gov (United States)

    Sell, Ana Maria; Visentainer, Jeane Eliete Laguila

    2015-01-01

    The study of erythrocyte antigens continues to be an intense field of research, particularly after the development of molecular testing methods. More than 300 specificities have been described by the International Society for Blood Transfusion as belonging to 33 blood group systems. The polymerase chain reaction (PCR) is a central tool for red blood cells (RBC) genotyping. PCR and agarose gel electrophoresis are low cost, easy, and versatile in vitro methods for amplifying defined target DNA (RBC polymorphic region). Multiplex-PCR, AS-PCR (Specific Allele Polymerase Chain Reaction), and RFLP-PCR (Restriction Fragment Length Polymorphism-Polymerase Chain Reaction) techniques are usually to identify RBC polymorphisms. Furthermore, it is an easy methodology to implement. This chapter describes the PCR methodology and agarose gel electrophoresis to identify the polymorphisms of the Kell, Duffy, Kidd, and MNS blood group systems.

  2. Fractionation of SWNT/nucleic acid complexes by agarose gel electrophoresis

    International Nuclear Information System (INIS)

    Vetcher, Alexandre A; Srinivasan, Srimeenakshi; Vetcher, Ivan A; Abramov, Semen M; Kozlov, Mikhail; Baughman, Ray H; Levene, Stephen D

    2006-01-01

    We show that aqueous dispersions of single-walled carbon nanotubes (SWNTs), prepared with the aid of nucleic acids (NAs) such as RNA or DNA, can be separated into fractions using agarose gel electrophoresis. In a DC electric field, SWNT/NA complexes migrate in the gel in the direction of positive potential to form well-defined bands. Raman spectroscopy as a function of band position shows that nanotubes having different spectroscopic properties possess different electrophoretic mobilities. The migration patterns for SWNT/RNA and SWNT/DNA complexes differ. Parallel elution of the SWNT/NA complexes from the gel during electrophoresis and subsequent characterization by AFM reveals differences in nanotube diameter, length and curvature. The results suggest that fractionation of nanotubes can be achieved by this procedure. We discuss factors affecting the mobility of the nanotube complexes and propose analytical applications of this technique

  3. A simple gel electrophoresis method for separating polyhedral gold nanoparticles

    Science.gov (United States)

    Kim, Suhee; Lee, Hye Jin

    2015-07-01

    In this paper, a simple approach to separate differently shaped and sized polyhedral gold nanoparticles (NPs) within colloidal solutions via gel electrophoresis is described. Gel running parameters for separating efficiently gold NPs including gel composition, added surfactant types and applied voltage were investigated. The plasmonic properties and physical structure of the separated NPs extracted from the gel matrix were then investigated using transmission electron microscopy (TEM) and UV-vis spectrophotometry respectively. Data analysis revealed that gel electrophoresis conditions of a 1.5 % agarose gel with 0.1 % sodium dodecyl sulfate (SDS) surfactant under an applied voltage of 100 V resulted in the selective isolation of ~ 50 nm polyhedral shaped gold nanoparticles. Further efforts are underway to apply the method to purify biomolecule-conjugated polyhedral Au NPs that can be readily used for NP-enhanced biosensing platforms.

  4. Fractionation of SWNT/nucleic acid complexes by agarose gel electrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Vetcher, Alexandre A [Institute of Biomedical Sciences and Technology and Department of Molecular and Cell Biology, University of Texas at Dallas, Richardson, TX 75083 (United States); Srinivasan, Srimeenakshi [Institute of Biomedical Sciences and Technology and Department of Molecular and Cell Biology, University of Texas at Dallas, Richardson, TX 75083 (United States); Vetcher, Ivan A [Institute of Biomedical Sciences and Technology and Department of Molecular and Cell Biology, University of Texas at Dallas, Richardson, TX 75083 (United States); Abramov, Semen M [NanoTech Institute, University of Texas at Dallas, Richardson, TX 75083 (United States); Kozlov, Mikhail [NanoTech Institute, University of Texas at Dallas, Richardson, TX 75083 (United States); Baughman, Ray H [NanoTech Institute, University of Texas at Dallas, Richardson, TX 75083 (United States); Levene, Stephen D [Institute of Biomedical Sciences and Technology and Department of Molecular and Cell Biology, University of Texas at Dallas, Richardson, TX 75083 (United States)

    2006-08-28

    We show that aqueous dispersions of single-walled carbon nanotubes (SWNTs), prepared with the aid of nucleic acids (NAs) such as RNA or DNA, can be separated into fractions using agarose gel electrophoresis. In a DC electric field, SWNT/NA complexes migrate in the gel in the direction of positive potential to form well-defined bands. Raman spectroscopy as a function of band position shows that nanotubes having different spectroscopic properties possess different electrophoretic mobilities. The migration patterns for SWNT/RNA and SWNT/DNA complexes differ. Parallel elution of the SWNT/NA complexes from the gel during electrophoresis and subsequent characterization by AFM reveals differences in nanotube diameter, length and curvature. The results suggest that fractionation of nanotubes can be achieved by this procedure. We discuss factors affecting the mobility of the nanotube complexes and propose analytical applications of this technique.

  5. Streamlined sign-out of capillary protein electrophoresis using middleware and an open-source macro application.

    Science.gov (United States)

    Mathur, Gagan; Haugen, Thomas H; Davis, Scott L; Krasowski, Matthew D

    2014-01-01

    Interfacing of clinical laboratory instruments with the laboratory information system (LIS) via "middleware" software is increasingly common. Our clinical laboratory implemented capillary electrophoresis using a Sebia(®) Capillarys-2™ (Norcross, GA, USA) instrument for serum and urine protein electrophoresis. Using Data Innovations Instrument Manager, an interface was established with the LIS (Cerner) that allowed for bi-directional transmission of numeric data. However, the text of the interpretive pathology report was not properly transferred. To reduce manual effort and possibility for error in text data transfer, we developed scripts in AutoHotkey, a free, open-source macro-creation and automation software utility. Scripts were written to create macros that automated mouse and key strokes. The scripts retrieve the specimen accession number, capture user input text, and insert the text interpretation in the correct patient record in the desired format. The scripts accurately and precisely transfer narrative interpretation into the LIS. Combined with bar-code reading by the electrophoresis instrument, the scripts transfer data efficiently to the correct patient record. In addition, the AutoHotKey script automated repetitive key strokes required for manual entry into the LIS, making protein electrophoresis sign-out easier to learn and faster to use by the pathology residents. Scripts allow for either preliminary verification by residents or final sign-out by the attending pathologist. Using the open-source AutoHotKey software, we successfully improved the transfer of text data between capillary electrophoresis software and the LIS. The use of open-source software tools should not be overlooked as tools to improve interfacing of laboratory instruments.

  6. TECHNIQUES WITH POTENTIAL FOR HANDLING ENVIRONMENTAL SAMPLES IN CAPILLARY ELECTROPHORESIS

    Science.gov (United States)

    An assessment of the methods for handling environmental samples prior to capillary electrophoresis (CE) is presented for both aqueous and solid matrices. Sample handling in environmental analyses is the subject of ongoing research at the Environmental Protection Agency's National...

  7. Electrophoresis gel image processing and analysis using the KODAK 1D software.

    Science.gov (United States)

    Pizzonia, J

    2001-06-01

    The present article reports on the performance of the KODAK 1D Image Analysis Software for the acquisition of information from electrophoresis experiments and highlights the utility of several mathematical functions for subsequent image processing, analysis, and presentation. Digital images of Coomassie-stained polyacrylamide protein gels containing molecular weight standards and ethidium bromide stained agarose gels containing DNA mass standards are acquired using the KODAK Electrophoresis Documentation and Analysis System 290 (EDAS 290). The KODAK 1D software is used to optimize lane and band identification using features such as isomolecular weight lines. Mathematical functions for mass standard representation are presented, and two methods for estimation of unknown band mass are compared. Given the progressive transition of electrophoresis data acquisition and daily reporting in peer-reviewed journals to digital formats ranging from 8-bit systems such as EDAS 290 to more expensive 16-bit systems, the utility of algorithms such as Gaussian modeling, which can correct geometric aberrations such as clipping due to signal saturation common at lower bit depth levels, is discussed. Finally, image-processing tools that can facilitate image preparation for presentation are demonstrated.

  8. Speciation of protein-bound trace elements by gel electrophoresis and atomic spectrometry.

    Science.gov (United States)

    Ma, Renli; McLeod, Cameron W; Tomlinson, Kerry; Poole, Robert K

    2004-08-01

    The metabolism of trace elements, in particular their binding to proteins in biological systems is of great importance in biochemical, toxicological, and pharmacological studies. As a result there has been a sustained interest over the last two decades in the speciation of protein-bound metals. Various analytical approaches have been employed, combining efficient separation of metalloproteins by liquid chromatography or electrophoresis with high-sensitivity elemental detection. Slab-gel electrophoresis (GE) is a key platform for high-resolution protein separation, and has been combined with autoradiography and various atomic spectrometric techniques for in-gel determination of protein-bound metals. Recently, the combination of GE with state-of-the-art inductively coupled plasma-mass spectrometry (ICP-MS), particularly when linked to laser ablation (LA) for direct gel interrogation, has opened up new opportunities for rapid characterization of metalloproteins. The use of GE and atomic spectrometry for the speciation of protein-bound trace elements is reviewed in this paper. Technical requirements for gel electrophoresis/atomic spectrometric measurement are considered in terms of method compatibilities, detection capability and potential usefulness. The literature is also surveyed to illustrate current status and future trends. Copyright 2004 Wiley-VCH Verlag GmbH and Co.

  9. The application of single cell gel electrophoresis or comet assay to human monitoring studies

    Directory of Open Access Journals (Sweden)

    Valverde Mahara

    1999-01-01

    Full Text Available Objective. In the search of new human genotoxic biomarkers, the single cell gel electrophoresis assay has been proposed as a sensible alternative. Material and methods. This technique detects principally single strand breaks as well as alkali-labile and repair-retarded sites. Results. Herein we present our experience using the single cell gel electrophoresis assay in human population studies, both occupationally and environmentally exposed. Conclusions. We discuss the assay feasibility as a genotoxic biomarker.

  10. Determination of propionate in bread using capillary zone electrophoresis

    NARCIS (Netherlands)

    Ackermans, M.T.; Ackermans-Loonen, J.C.J.M; Beckers, J.L.

    1992-01-01

    A method for the determination of propionate in bread is described. The propionate was extracted from the bread with a repeated extraction procedure and measured using capillary zone electrophoresis in the indirect UV mode applying a background electrolyte of 0.005 M Tris adjusted at pH 4.6 by

  11. Standardizing electrophoresis conditions: how to eliminate a major source of error in the comet assay.

    Directory of Open Access Journals (Sweden)

    Gunnar Brunborg

    2015-06-01

    Full Text Available In the alkaline comet assay, cells are embedded in agarose, lysed, and then subjected to further processing including electrophoresis at high pH (>13. We observed very large variations of mean comet tail lengths of cell samples from the same population when spread on a glass or plastic substrate and subjected to electrophoresis. These variations might be cancelled out if comets are scored randomly over a large surface, or if all the comets are scored. The mean tail length may then be representative of the population, although its standard error is large. However, the scoring process often involves selection of 50 – 100 comets in areas selected in an unsystematic way from a large gel on a glass slide. When using our 96-sample minigel format (1, neighbouring sample variations are easily detected. We have used this system to study the cause of the comet assay variations during electrophoresis and we have defined experimental conditions which reduce the variations to a minimum. We studied the importance of various physical parameters during electrophoresis: (i voltage; (ii duration of electrophoresis; (iii electric current; (iv temperature; and (v agarose concentration. We observed that the voltage (V/cm varied substantially during electrophoresis, even within a few millimetres of distance between gel samples. Not unexpectedly, both the potential ( V/cm and the time were linearly related to the mean comet tail, whereas the current was not. By measuring the local voltage with microelectrodes a few millimetres apart, we observed substantial local variations in V/cm, and they increased with time. This explains the large variations in neighbouring sample comet tails of 25% or more. By introducing simple technology (circulation of the solution during electrophoresis, and temperature control, these variations in mean comet tail were largely abolished, as were the V/cm variations. Circulation was shown to be particularly important and optimal conditions

  12. Use of Electrophoresis for Transporting Nano-Iron in Porous Media

    Science.gov (United States)

    Research was conducted to evaluate if electrophoresis could transport surface stabilized nanoscale zero-valent iron (nZVI) through fine grained sand with the intent of remediating a contaminant in situ. The experimental procedure involved determining the transport rates of poly...

  13. Success and failure with phthalate buffers in capillary zone electrophoresis

    NARCIS (Netherlands)

    Bocek, P.; Gebauer, P.; Beckers, J.L.

    2001-01-01

    Phthalate buffers are currently used in capillary electrophoresis as robust electrolyte systems for indirect detection. This contribution demonstrates that these buffers show regularly not only successful regions of mobilities of analytes (sample window) but also regions of failure where the

  14. Gel Electrophoresis and Fluorescamine Methods for the Detection of ...

    African Journals Online (AJOL)

    For the fluorescamine method, clarification was achieved by isoelectric precipitation and precipitation with acid to obtain pH 4.6 and 6% TCA soluble extracts respectively. Non-clarified samples were used for gel electrophoresis. Both methods confirmed that raw milk and milk processed at 85/15s were the most proteolysed, ...

  15. Capillary electrophoresis and nanomaterials - Part I: Capillary electrophoresis of nanomaterials.

    Science.gov (United States)

    Adam, Vojtech; Vaculovicova, Marketa

    2017-10-01

    Nanomaterials are in analytical science used for a broad range of purposes, covering the area of sample pretreatment as well as separation, detection, and identification of target molecules. This part of the review covers capillary electrophoresis (CE) of nanomaterials and focuses on the application of CE as a method for characterization used during nanomaterial synthesis and modification as well as the monitoring of their properties and interactions with other molecules. The heterogeneity of the nanomaterial family is extremely large. Depending on different definitions of the term Nanomaterial/Nanoparticle, the group may cover metal and polymeric nanoparticles, carbon nanomaterials, liposomes and even dendrimers. Moreover, these nanomaterials are usually subjected to some kind of surface modification or functionalization, which broadens the diversity even more. Not only for purposes of verification of nanomaterial synthesis and batch-to-batch quality check, but also for determination the polydispersity and for functionality characterization on the nanoparticle surface, has CE offered very beneficial capabilities. Finally, the monitoring of interactions between nanomaterials and other (bio)molecules is easily performed by some kind of capillary electromigration technique. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Defining carbohydrate binding of glucan phosphatases via Affinity gel electrophoresis

    DEFF Research Database (Denmark)

    Auger, Kyle; Raththagala, Madushi; Wilkens, Casper

    2016-01-01

    was to determine a technique to measure carbohydrate binding quickly and efficiently. We established a protocol to reproducibly and quantitatively measure the binding of the enzymes to glucans utilizing Affinity Gel Electrophoresis (AGE). The results show that the various glucan phosphatases possess differing...

  17. New multilayer coating using quaternary ammonium chitosan and κ-carrageenan in capillary electrophoresis: application in fast analysis of betaine and methionine.

    Science.gov (United States)

    Vitali, Luciano; Della Betta, Fabiana; Costa, Ana Carolina O; Vaz, Fernando Antonio Simas; Oliveira, Marcone Augusto Leal; Vistuba, Jacqueline Pereira; Fávere, Valfredo T; Micke, Gustavo A

    2014-06-01

    The aim of this study was to develop a new multilayer coating with crosslinked quaternary ammonium chitosan (hydroxypropyltrimethyl ammonium chloride chitosan; HACC) and κ-carrageenan for use in capillary electrophoresis. A new semi-permanent multilayer coating was formed using the procedure developed and the method does not require the presence of polymers in the background electrolyte (BGE). The new capillary multilayer coating showed a cathodic electroosmotic flow (EOF) of around 30×10(-9) m(2) V(-1) s(-1) which is pH-independent in the range of pH 2 to 10. The enhanced EOF at low pH obtained contributed significantly to the development of a fast method of separation. The multilayer coating was then applied in the development of a fast separation method to determine betaine and methionine in pharmaceutical formulations by capillary zone electrophoresis (CZE). The BGE used to determine the betaine and methionine concentrations was composed of 10 mmol L(-1) tris(hydroxymethyl) aminomethane, 40 mmol L(-1) phosphoric acid and 10% (v/v) ethanol, at pH 2.1. A fused-silica capillary of 32 cm (50 µm ID×375 µm OD) was used in the experiments and samples and standards were analyzed employing the short-end injection procedure (8.5 cm effective length). The instrumental analysis time of the optimized method was 1.53 min (approx. 39 runs per hour). The validation of the proposed method for the determination of betaine and methionine showed good linearity (R(2)>0.999), adequate limit of detection (LOD <8 mg L(-1)) for the concentration in the samples and inter-day precision values lower than 3.5% (peak area and time migration). The results for the quantification of the amino acids in the samples determined by the CZE-UV method developed were statistically equal to those obtained with the comparative LC-MS/MS method according to the paired t-test with a confidence level of 95%. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Microchip Electrophoresis at Elevated Temperatures and High Separation Field Strengths

    Science.gov (United States)

    Mitra, Indranil; Marczak, Steven P.; Jacobson, Stephen C.

    2014-01-01

    We report free-solution microchip electrophoresis performed at elevated temperatures and high separation field strengths. We used microfluidic devices with 11-cm long separation channels to conduct separations at temperatures between 22 (ambient) and 45 °C and field strengths from 100 to 1000 V/cm. To evaluate separation performance, N-glycans were used as a model system and labeled with 8-aminopyrene-1,3,6-trisulfonic acid to impart charge for electrophoresis and render them fluorescent. Typically, increased diffusivity at higher temperatures leads to increased axial dispersion and poor separation performance; however, we demonstrate that sufficiently high separation field strengths can be used to offset the impact of increased diffusivity in order to maintain separation efficiency. Efficiencies for these free-solution separations are the same at temperatures of 25, 35, and 45 °C with separation field strengths ≥500 V/cm. PMID:24114979

  19. Streamlined sign-out of capillary protein electrophoresis using middleware and an open-source macro application

    Directory of Open Access Journals (Sweden)

    Gagan Mathur

    2014-01-01

    Full Text Available Background: Interfacing of clinical laboratory instruments with the laboratory information system (LIS via "middleware" software is increasingly common. Our clinical laboratory implemented capillary electrophoresis using a Sebia; Capillarys-2™ (Norcross, GA, USA instrument for serum and urine protein electrophoresis. Using Data Innovations Instrument Manager, an interface was established with the LIS (Cerner that allowed for bi-directional transmission of numeric data. However, the text of the interpretive pathology report was not properly transferred. To reduce manual effort and possibility for error in text data transfer, we developed scripts in AutoHotkey, a free, open-source macro-creation and automation software utility. Materials and Methods: Scripts were written to create macros that automated mouse and key strokes. The scripts retrieve the specimen accession number, capture user input text, and insert the text interpretation in the correct patient record in the desired format. Results: The scripts accurately and precisely transfer narrative interpretation into the LIS. Combined with bar-code reading by the electrophoresis instrument, the scripts transfer data efficiently to the correct patient record. In addition, the AutoHotKey script automated repetitive key strokes required for manual entry into the LIS, making protein electrophoresis sign-out easier to learn and faster to use by the pathology residents. Scripts allow for either preliminary verification by residents or final sign-out by the attending pathologist. Conclusions: Using the open-source AutoHotKey software, we successfully improved the transfer of text data between capillary electrophoresis software and the LIS. The use of open-source software tools should not be overlooked as tools to improve interfacing of laboratory instruments.

  20. Recent progress in preparation and application of microfluidic chip electrophoresis

    International Nuclear Information System (INIS)

    Cong, Hailin; Xu, Xiaodan; Yu, Bing; Yuan, Hua; Peng, Qiaohong; Tian, Chao

    2015-01-01

    Since its discovery in 1990, microfluidic chip electrophoresis (MCE) has allowed the development of applications with small size, fast analysis, low cost, high integration density and automatic level, which are easy to carry and have made commercialization efficient. MCE has been widely used in the areas of environmental protection, biochemistry, medicine and health, clinical testing, judicial expertise, food sanitation, pharmaceutical checking, drug testing, agrochemistry, biomedical engineering and life science. As one of the foremost fields in the research of capillary electrophoresis, MCE is the ultimate frontier to develop the miniaturized, integrated, automated all-in-one instruments needed in modern analytical chemistry. By adopting the advanced technologies of micro-machining, lasers and microelectronics, and the latest research achievements in analytical chemistry and biochemistry, the sampling, separation and detection systems of commonly used capillary electrophoresis are integrated with high densities onto glass, quartz, silicon or polymer wafers to form the MCE, which can finish the analysis of multi-step operations such as injection, enrichment, reaction, derivatization, separation, and collection of samples in a portable, efficient and super high speed manner. With reference to the different technological achievements in this area, the latest developments in MCE are reviewed in this article. The preparation mechanisms, surface modifications, and properties of different materials in MCE are compared, and the different sampling, separation and detection systems in MCE are summarized. The performance of MCE in analysis of fluorescent substance, metallic ion, sugar, medicine, nucleic acid, DNA, amino acid, polypeptide and protein is discussed, and the future direction of development is forecast. (topical review)

  1. Recent progress in preparation and application of microfluidic chip electrophoresis

    Science.gov (United States)

    Cong, Hailin; Xu, Xiaodan; Yu, Bing; Yuan, Hua; Peng, Qiaohong; Tian, Chao

    2015-05-01

    Since its discovery in 1990, microfluidic chip electrophoresis (MCE) has allowed the development of applications with small size, fast analysis, low cost, high integration density and automatic level, which are easy to carry and have made commercialization efficient. MCE has been widely used in the areas of environmental protection, biochemistry, medicine and health, clinical testing, judicial expertise, food sanitation, pharmaceutical checking, drug testing, agrochemistry, biomedical engineering and life science. As one of the foremost fields in the research of capillary electrophoresis, MCE is the ultimate frontier to develop the miniaturized, integrated, automated all-in-one instruments needed in modern analytical chemistry. By adopting the advanced technologies of micro-machining, lasers and microelectronics, and the latest research achievements in analytical chemistry and biochemistry, the sampling, separation and detection systems of commonly used capillary electrophoresis are integrated with high densities onto glass, quartz, silicon or polymer wafers to form the MCE, which can finish the analysis of multi-step operations such as injection, enrichment, reaction, derivatization, separation, and collection of samples in a portable, efficient and super high speed manner. With reference to the different technological achievements in this area, the latest developments in MCE are reviewed in this article. The preparation mechanisms, surface modifications, and properties of different materials in MCE are compared, and the different sampling, separation and detection systems in MCE are summarized. The performance of MCE in analysis of fluorescent substance, metallic ion, sugar, medicine, nucleic acid, DNA, amino acid, polypeptide and protein is discussed, and the future direction of development is forecast.

  2. Stacking gels: A method for maximising output for pulsed-field gel electrophoresis

    Directory of Open Access Journals (Sweden)

    Heng See

    2009-01-01

    Full Text Available Pulsed field gel electrophoresis (PFGE, the gold standard of molecular typing methods, has a major disadvantage of an unusually long electrophoretic time. From the original protocol of 6 days, it was modified to 3 days and subsequently to a single day. We describe the procedure of stacking five to six gels one on top of another in order to increase and maximize the output in a shorter time without compromising the resolution and reproducibility. All the variables that affect pulsed field gels during electrophoresis were taken into consideration. We firstly optimized the parameters to be used and secondly determined whether stacking of five to six gels had any effect on the molecular separation during electrophoresis in comparison with a single gel run. DNA preparation, restriction, electrophoresis, staining and gel documentation was carried out based on previously published methods. Gels were analysed using BioNumerics and dice coefficient and unweighted pair group methods were used to generate dendrograms based on 1.5% tolerance values. Identical band profiles and band resolution-separation were seen in the PFGE patterns with single gel and multiple stacking gels. Cluster analysis further strengthened the fact that results from stacking gels were reproducible and comparable with a single gel run. This method of stacking gels saves time and maximizes the output at the same time. The run time for a single gel was about 28 hours, but with six stacked gels the run time was 54 hours compared with 28 x 6 = 168 hours if they were run separately as single gels thus saving time of 67.86%. Beside the big factor of saving time, stacking gels save resources (electricity, reagents, water, chemicals and working time by increasing the sample throughput in a shorter time without compromising on quality of data. But optimization of working parameters is vital depending on the PFGE system used.

  3. Trace analysis of organic ions in ice samples by capillary electrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Huber, T. [Bern Univ. (Switzerland); Schwikowski, M.; Gaeggeler, H.W. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-09-01

    Capillary electrophoresis was tested as a new analytical method for ice samples. Comparisons to ion chromatography were made concerning accuracy, detection limits, reproducibility, necessary sample volume and time consumption. (author) 1 fig., 3 refs.

  4. Trace analysis of organic ions in ice samples by capillary electrophoresis

    International Nuclear Information System (INIS)

    Huber, T.; Schwikowski, M.; Gaeggeler, H.W.

    1997-01-01

    Capillary electrophoresis was tested as a new analytical method for ice samples. Comparisons to ion chromatography were made concerning accuracy, detection limits, reproducibility, necessary sample volume and time consumption. (author) 1 fig., 3 refs

  5. Evaluation and optimisation of preparative semi-automated electrophoresis systems for Illumina library preparation.

    Science.gov (United States)

    Quail, Michael A; Gu, Yong; Swerdlow, Harold; Mayho, Matthew

    2012-12-01

    Size selection can be a critical step in preparation of next-generation sequencing libraries. Traditional methods employing gel electrophoresis lack reproducibility, are labour intensive, do not scale well and employ hazardous interchelating dyes. In a high-throughput setting, solid-phase reversible immobilisation beads are commonly used for size-selection, but result in quite a broad fragment size range. We have evaluated and optimised the use of two semi-automated preparative DNA electrophoresis systems, the Caliper Labchip XT and the Sage Science Pippin Prep, for size selection of Illumina sequencing libraries. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Comparison of hydrodynamically closed isotachophoresis-capillary zone electrophoresis with hydrodynamically open capillary zone electrophoresis hyphenated with tandem mass spectrometry in drug analysis: pheniramine, its metabolite and phenylephrine in human urine.

    Science.gov (United States)

    Piešťanský, Juraj; Maráková, Katarína; Kovaľ, Marián; Mikuš, Peter

    2014-09-05

    The advanced two dimensional isotachophoresis (ITP)-capillary zone electrophoresis (CZE) hyphenated with tandem mass spectrometry (MS/MS, here triple quadrupole, QqQ) was developed in this work to demonstrate analytical potentialities of this approach in the analysis of drugs in multicomponent ionic matrices. Pheniramine (PHM), phenylephrine (PHE), paracetamol (PCM) and their potential metabolic products were taken for the analysis by the ITP-CZE-ESI-QqQ technique working in hydrodynamically closed CE separation system and then a comparison with the conventional (hydrodynamically open) CZE-ESI-QqQ technique was made. The ITP-CZE-ESI-QqQ method was favorable in terms of obtainable selectivity (due to highly effective heart-cut analysis), concentration limits of detection (LOD at pgmL(-1) levels due to enhanced sample load capacity and ITP preconcentration), sample handling (on-line sample pretreatment, i.e. clean-up, preconcentration, preseparation), and, by that, possibilities for future automation and miniaturization. On the other hand, this experimental arrangement, in contrast to the CZE-ESI-QqQ arrangement supported by an electroosmotic flow, is principally limited to the analysis of uniformly (i.e. positively or negatively) charged analytes in one run without any possibilities to analyze neutral compounds (here, PCM and neutral or acidic metabolites of the drugs had to be excluded from the analysis). Hence, these general characteristics should be considered when choosing a proper analytical CE-MS approach for a given biomedical application. Here, the analytical potential of the ITP-CZE-ESI-QqQ method was demonstrated showing the real time profiles of excreted targeted drugs and metabolite (PHM, PHE, M-PHM) in human urine after the administration of one dose of Theraflu(®) to the volunteers. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Microchip capillary electrophoresis for point-of-care analysis of lithium

    NARCIS (Netherlands)

    Vrouwe, E.X.; Luttge, R.; Vermes, I.; Berg, van den A.

    2007-01-01

    Background: Microchip capillary electrophoresis (CE) is a promising method for chemical analysis of complex samples such as whole blood. We evaluated the method for point-of-care testing of lithium. Methods: Chemical separation was performed on standard glass microchip CE devices with a conductivity

  8. Identification of column edges of DNA fragments by using K-means clustering and mean algorithm on lane histograms of DNA agarose gel electrophoresis images

    Science.gov (United States)

    Turan, Muhammed K.; Sehirli, Eftal; Elen, Abdullah; Karas, Ismail R.

    2015-07-01

    Gel electrophoresis (GE) is one of the most used method to separate DNA, RNA, protein molecules according to size, weight and quantity parameters in many areas such as genetics, molecular biology, biochemistry, microbiology. The main way to separate each molecule is to find borders of each molecule fragment. This paper presents a software application that show columns edges of DNA fragments in 3 steps. In the first step the application obtains lane histograms of agarose gel electrophoresis images by doing projection based on x-axis. In the second step, it utilizes k-means clustering algorithm to classify point values of lane histogram such as left side values, right side values and undesired values. In the third step, column edges of DNA fragments is shown by using mean algorithm and mathematical processes to separate DNA fragments from the background in a fully automated way. In addition to this, the application presents locations of DNA fragments and how many DNA fragments exist on images captured by a scientific camera.

  9. Non-ionic, thermo-responsive DEA/DMA nanogels: synthesis, characterization, and use for DNA separations by microchip electrophoresis.

    Science.gov (United States)

    Lu, Xihua; Sun, Mingyun; Barron, Annelise E

    2011-05-15

    Thermo-responsive polymer "nanogels" (crosslinked hydrogel particles with sub-100 nm diameters) are intriguing for many potential applications in biotechnology and medicine. There have been relatively few reports of electrostatically neutral, thermosensitive nanogels comprising a high fraction of hydrophilic co-monomer. Here we demonstrate the syntheses and characterization of novel, non-ionic nanogels based on random N,N-diethylacrylamide (DEA)/N,N-dimethylacrylamide (DMA) copolymers, made by free-radical, surfactant-free dispersion polymerization. The volume-phase transition temperatures of these DEA/DMA nanogels are strongly affected by co-monomer composition, providing a way to "tune" the phase transition temperature of these non-ionic nanogels. While DEA nanogels (comprising no DMA) can be obtained at 70 °C by standard emulsion precipitation, DEA/DMA random co-polymer nanogels can be obtained only in a particular range of temperatures, above the initial phase transition temperature and below the critical precipitation temperature of the DEA/DMA copolymer, controlled by co-monomer composition. Increasing percentages of DMA in the nanogels raises the phase transition temperature, and attenuates and broadens it as well. We find that concentrated DEA/DMA nanogel dispersions are optically clear at room temperature. This good optical clarity was exploited for their use in a novel DNA sieving matrix for microfluidic chip electrophoresis. An ultrafast, high-efficiency dsDNA separation was achieved in less than 120 s for dsDNA ranging from 75 bp to 15,000 bp. Copyright © 2011 Elsevier Inc. All rights reserved.

  10. In-vial liquid-liquid microextraction-capillary electrophoresis method for the determination of phenolic acids in vegetable oils.

    Science.gov (United States)

    Abu Bakar, Nur Bahiyah; Makahleh, Ahmad; Saad, Bahruddin

    2012-09-12

    An in-vial liquid-liquid microextraction method was developed for the selective extraction of the phenolic acids (caffeic, gallic, cinnamic, ferulic, chlorogenic, syringic, vanillic, benzoic, p-hydroxybenzoic, 2,4-dihydroxybenzoic, o-coumaric, m-coumaric and p-coumaric) in vegetable oil samples. The optimised extraction conditions for 20 g sample were: volume of diluent (n-hexane), 2 mL; extractant, methanol: 5 mM sodium hydroxide (60:40; v/v); volume of extractant, 300 μL (twice); vortex, 1 min; centrifugation, 5 min. Recoveries for the studied phenolic acids were 80.1-119.5%. The simultaneous determination of the phenolic acid extracts was investigated by capillary electrophoresis (CE). Separations were carried out on a bare fused-silica capillary (50 μm i.d.× 40 cm length) involving 25 mM sodium tetraborate (pH 9.15) and 5% methanol as CE background electrolyte in the normal polarity mode, voltage of 30 kV, temperature of 25°C, injection time of 4s (50 mbar) and electropherograms were recorded at 200 nm. The phenolic acids were successfully separated in less than 10 min. The validated in-vial LLME-CE method was applied to the determination of phenolic acids in vegetable oil samples (extra virgin olive oil, virgin olive oil, pure olive oil, walnut oil and grapeseed oil). The developed method shows significant advantages over the current methods as lengthy evaporation step is not required. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Importance of core electrostatic properties on the electrophoresis of a soft particle

    Science.gov (United States)

    De, Simanta; Bhattacharyya, Somnath; Gopmandal, Partha P.

    2016-08-01

    The impact of the volumetric charged density of the dielectric rigid core on the electrophoresis of a soft particle is analyzed numerically. The volume charge density of the inner core of a soft particle can arise for a dendrimer structure or bacteriophage MS2. We consider the electrokinetic model based on the conservation principles, thus no conditions for Debye length or applied electric field is imposed. The fluid flow equations are coupled with the ion transport equations and the equation for the electric field. The occurrence of the induced nonuniform surface charge density on the outer surface of the inner core leads to a situation different from the existing analysis of a soft particle electrophoresis. The impact of this induced surface charge density together with the double-layer polarization and relaxation due to ion convection and electromigration is analyzed. The dielectric permittivity and the charge density of the core have a significant impact on the particle electrophoresis when the Debye length is in the order of the particle size. We find that by varying the ionic concentration of the electrolyte, the particle can exhibit reversal in its electrophoretic velocity. The role of the polymer layer softness parameter is addressed in the present analysis.

  12. Short communication: Identification of coagulase-negative staphylococcus species from goat milk with the API Staph identification test and with transfer RNA-intergenic spacer PCR combined with capillary electrophoresis.

    Science.gov (United States)

    Koop, G; De Visscher, A; Collar, C A; Bacon, D A C; Maga, E A; Murray, J D; Supré, K; De Vliegher, S; Haesebrouck, F; Rowe, J D; Nielen, M; van Werven, T

    2012-12-01

    Coagulase-negative staphylococci (CNS) are the most commonly isolated bacteria from goat milk, but they have often been identified with phenotypic methods, which may have resulted in misclassification. The aims of this paper were to assess the amount of misclassification of a phenotypic test for identifying CNS species from goat milk compared with transfer RNA intergenic spacer PCR (tDNA-PCR) followed by capillary electrophoresis, and to apply the tDNA-PCR technique on different capillary electrophoresis equipment. Milk samples were collected from 416 does in 5 Californian dairy goat herds on 3 occasions during lactation. In total, 219 CNS isolates were identified at the species level with tDNA-PCR and subjected to the API 20 Staph identification test kit (API Staph; bioMérieux, Durham, NC). If the same species was isolated multiple times from the same udder gland, only the first isolate was used for further analyses, resulting in 115 unique CNS isolates. According to the tDNA-PCR test, the most prevalent CNS species were Staphylococcus epidermidis, Staphylococcus caprae, and Staphylococcus simulans. Typeability with API staph was low (72%). Although the API Staph test was capable of identifying the majority of Staph. epidermidis and Staph. caprae isolates, sensitivity for identification of Staph. simulans was low. The true positive fraction was high for the 3 most prevalent species. It was concluded that the overall performance of API Staph in differentiating CNS species from goat milk was moderate to low, mainly because of the low typeability, and that genotypic methods such as tDNA-PCR are preferred. Copyright © 2012 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  13. Strain identification in Rhizobium by starch gel electrophoresis of isoenzymes

    DEFF Research Database (Denmark)

    Engvild, Kjeld Christensen; Nielsen, G.

    1985-01-01

    Sonieated extracts of rhizobia, especiaUy Rhizobium leguminosarum from pea and vetch, were run in horizontal starch gel electrophoresis in the cold. The rhizobia were grown on agar on a slime suppressing substrate of tryptone-yeast extract-CaCl2 with small amounts of mannitol, sorbitol...

  14. Gel versus capillary electrophoresis genotyping for categorizing treatment outcomes in two anti-malarial trials in Uganda

    OpenAIRE

    Hubbard Alan E; Dorsey Grant; Gupta Vinay; Rosenthal Philip J; Greenhouse Bryan

    2010-01-01

    Abstract Background Molecular genotyping is performed in anti-malarial trials to determine whether recurrent parasitaemia after therapy represents a recrudescence (treatment failure) or new infection. The use of capillary instead of agarose gel electrophoresis for genotyping offers technical advantages, but it is unclear whether capillary electrophoresis will result in improved classification of anti-malarial treatment outcomes. Methods Samples were genotyped using both gel and capillary elec...

  15. On-line detection of small radioactive ions by capillary electrophoresis

    International Nuclear Information System (INIS)

    Klunder, G.L.; Andrews, J.E. Jr.; Russo, R.E.

    1994-01-01

    Worldwide environmental interests have placed a great demand on developing techniques for rapid characterization of contaminated soil and groundwater. Detection of radioactive contaminants is necessary for monitoring effluents from nuclear processes or to assure proper long term storage of radioactive waste. The authors have been investigating the chemistry required to separate representative radioactive small cations and anions by capillary electrophoresis. In order to evaluate the separation chemistry, detection of stable isotopes of the representative ions was achieved by indirect absorption for cations and direct absorption for anions. Several buffer systems which have been considered in the optimization of the separations will be discussed. The authors have designed and tested two on-line radioactivity detectors for capillary electrophoresis. An on-line solid state CdTe detector was constructed for this study and a scintillation detector has been designed using a high gain photodiode light sensor. Different scintillation materials have been tested. Comparison of the detectors, design considerations, efficiency and limits of detection will be presented

  16. Radioiodination of surface proteins of bull spermatozoa and their characterization by sodium dodecyl sulphate-polyacrylamide gel electrophoresis

    International Nuclear Information System (INIS)

    Vierula, M.

    1980-01-01

    Surface proteins of ejaculated bull spermatozoa were radioiodinated using Ma 125 I, solubilized and characterized by sodium dodecyl sulphate-polyacrylamide gel electrophoresis. The electron microscopic autoradiographs showed that the labelling was equally distributed to all parts of the spermatozoon and restricted to the sperm surface. The electrophoresis of solubilized radioactivity revealed 6 radioactive fractions with approximate molecular weights of 67 000-69 000, 47 000-50 000, 34 000-37 000, 25 000-28 000 and 14 000-16 000. The 6th fraction probably represented labelled lipids. The electrophoresis of radioiodinated seminal plasma proteins revealed only 2 radioactive protein peaks which coincided with the sperm surface protein fractions IV and V. (author)

  17. Monoclonal protein reference change value as determined by gel-based serum protein electrophoresis.

    Science.gov (United States)

    Salamatmanesh, Mina; McCudden, Christopher R; McCurdy, Arleigh; Booth, Ronald A

    2018-01-01

    The International Myeloma Working Group recommendations for monitoring disease progression or response include quantitation of the involved monoclonal immunoglobulin. They have defined the minimum change criteria of ≧25% with an absolute change of no gel-based serum protein electrophoresis. Sixteen clinically stable MGUS patients were identified from our clinical hematology database. Individual biological variability (CVi) was determined and used to calculate a monoclonal protein reference change value (RCV). Analytical variability of the normal protein fractions (albumin, alpha-1, alpha-2, beta, total gamma) ranged from 1.3% for albumin to 5.8% for the alpha-1 globulins. CVa of low (5.6g/L) and high (32.2g/L) concentration monoclonal proteins were 3.1% and 22.2%, respectively. Individual CVi of stable patients ranged from 3.5% to 24.5% with a CVi of 12.9%. The reference change value (RCV) at a 95% probability was determined to be 36.7% (low) 39.6% (high) using our CVa and CVi. Serial monitoring of monoclonal protein concentration is important for MGUS and multiple myeloma patients. Accurate criteria for interpreting a change in monoclonal protein concentration are required for appropriate decision making. We used QC results and real-world conditions to assess imprecision of serum protein fractions including low and high monoclonal protein fractions and clinically stable MGUS patients to determine CVi and RCV. The calculated RCVs of 36.7% (low) and 39.6% (high) in this study were greater that reported previously and greater than the established criteria for relapse. Response criteria may be reassessed to increase sensitivity and specificity for detection of response. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  18. Enhanced resolution of DNA restriction fragments: A procedure by two-dimensional electrophoresis and double-labeling

    International Nuclear Information System (INIS)

    Yi, M.; Au, L.C.; Ichikawa, N.; Ts'o, P.O.

    1990-01-01

    A probe-free method was developed to detect DNA rearrangement in bacteria based on the electrophoretic separation of twice-digested restriction fragments of genomic DNA into a two-dimensional (2-D) pattern. The first restriction enzyme digestion was done in solution, followed by electrophoresis of the restriction fragments in one dimension. A second restriction enzyme digestion was carried out in situ in the gel, followed by electrophoresis in a second dimension perpendicular to the first electrophoresis. The 2-D pattern provides for the resolution of 300-400 spots, which are defined and indexed by an x,y coordinate system with size markers. This approach has greatly increased the resolution power over conventional one-dimensional (1-D) electrophoresis. To study DNA rearrangement, a 2-D pattern from a test strain was compared with the 2-D pattern from a reference strain. After the first digestion, genomic DNA fragments from the test strain were labeled with 35S, while those from the reference strain were labeled with 32P. This was done to utilize the difference in the energy emission of 35S and 32P isotopes for autoradiography when two x-ray films were exposed simultaneously on top of the gel after the 2-D electrophoresis. The irradiation from the decay of 35S exposed only the lower film, whereas the irradiation from the decay of 32P exposed both the lower and upper films. Different DNA fragments existed in the test DNA compared with the reference DNA can be identified unambiguously by the differential two 2-D patterns produced on two films upon exposure to the 35S and 32P fragments in the same gel. An appropriate photographic procedure further simplified the process, allowing only the difference in DNA fragments between these two patterns to be shown in the map

  19. [Analysis of Cut-off Value in Screening of Thalassemia by Capillary Hemoglobin Electrophoresis for Pregnant Women from Shenzhen Region of China].

    Science.gov (United States)

    Huo, Mei; Wu, Wen-Yuan; Liu, Mei; Gan, Zhi-Biao; Mao, Wei-Yu; Lin, Rong-Yao; Liu, Ai-Qin; He, Gui-Rong

    2016-04-01

    To investigate the cut-off value in screening of thalassemia in pregnant women from Shenzhen region by capillary hemoglobin electrophoresis. The data of capillary hemoglobin electrophoresis and genetic diagnosis of thalassemia from 2122 examined prenatal women were retrospectively analyzed. Capillary hemoglobin electrophoresis and α-, β- genetic diagnosis of thalassemia were carried out for every woman. Hemoglobin electrophoresis was performed using Capillarys 2 full-automated electrophoresis instrument. Gap polymerase chain reaction and reverse dot blot were used for genetic diagnosis of thalassemia genotyping test. The cut-off value in screening of thalassemia was determined by receiver operating characteristic curve and next to analyze the value of HbA2 and HbF in screening of thalassemia using the decided cut-off value. The areas under the curve (AUC(Roc)) of HbA2 for diagnosis of α-, β- thalassemia were 0.75 and 0.981 respectively, and the AUC(Roc) of HbF for diagnosis of β-thalassemia was 0.787. When HbA2 ≤ 2.55 was taken as the cut-off value of HbA2 for diagnosis of α-thalassemia, the sensitivity, specificity, positive likelihood ratio (LR(+)) and negative likelihood ratio (LR(-)) were 89.5%, 54.8%, 1.98, 0.19 respectively. When HbA2 ≥3.9 was taken as the cut off value of HbA2 for diagnosis of β-thalassemia, the sensitivity, specificity, LR(+) and LR(-) were 96.1%, 99.8% 480.5, 0.04 respectively. When HbF ≥0.75 was taken as the cut off value of HbF for diagnosis of β-thalassemia, the sensitivity, specificity, LR(+) and LR(-) were 83.6%, 61.8% respectively. The cut-off value in screening of thalassemia by capillarys 2 full automated electrophoresis instrument is different from that of the traditional method of hemoglobin electrophoresis, such as cellulose acetate membrane electrophoresis and agarose gel electrophoresis. Each laboratory should establish their own respective cut off value.

  20. Pulsed-field Gel Electrophoresis for Salmonella Infection Surveillance, Texas, USA, 2007

    Centers for Disease Control (CDC) Podcasts

    This podcast describes monitoring of the use of pulsed-field gel electrophoresis for Salmonella surveillance in Houston, Texas. CDC microbiologist Peter Gerner-Smidt discusses the importance of the PulseNet national database in surveillance of food-borne infections.

  1. Rapid DNA sequencing by horizontal ultrathin gel electrophoresis.

    OpenAIRE

    Brumley, R L; Smith, L M

    1991-01-01

    A horizontal polyacrylamide gel electrophoresis apparatus has been developed that decreases the time required to separate the DNA fragments produced in enzymatic sequencing reactions. The configuration of this apparatus and the use of circulating coolant directly under the glass plates result in heat exchange that is approximately nine times more efficient than passive thermal transfer methods commonly used. Bubble-free gels as thin as 25 microns can be routinely cast on this device. The appl...

  2. Sodium dodecyl sulfate-capillary gel electrophoresis of polyethylene glycolylated interferon alpha.

    Science.gov (United States)

    Na, Dong H; Park, Eun J; Youn, Yu S; Moon, Byung W; Jo, Yeong W; Lee, Sung H; Kim, Won-Bae; Sohn, Yeowon; Lee, Kang C

    2004-02-01

    Sodium dodecyl sulfate-capillary gel electrophoresis (SDS-CGE) using a hydrophilic replaceable polymer network matrix was applied to characterize the polyethylene glycol(PEG)ylated interferon alpha (PEG-IFN). The SDS-CGE method resulted in a clearer resolution in both the PEG-IFN species and the native IFN species. The distribution profile of PEGylation determined by SDS-CGE was consistent with that obtained by SDS-polyacrylamide gel electrophoresis (PAGE) with Coomassie blue or barium iodide staining. The result was also compared using matrix-assisted laser desorption/ionization-time of flight-mass spectrometry. SDS-CGE was also useful for monitoring the PEGylation reaction to optimize the reaction conditions, such as reaction molar ratio. This study shows the potential of SDS-CGE as a new method for characterizing the PEGylated proteins with advantages of speed, minimal sample consumption and high resolution.

  3. Proposal of New Rewritable Printing Media Using Electrophoresis and Confirmation of Its Mechanism

    Science.gov (United States)

    Hoshino, Yasushi; Ogura, Masahiro; Sano, Takayuki

    2004-10-01

    A new rewritable printing media using electrophoresis and selective heating is proposed to contribute to the reduction in paper consumption by printers. The mechanism is that when a heated part of the rewritable media is melted, white particles in that part of the media are able to move by electrophoresis. The media is initialized by heating its entire surface under the condition of voltage application and imaging is carried out by selective heating under the condition of an applied reversed-polarity voltage. Using a mixture system of carnauba wax and particles coated with titanium oxide (TiO2), the feasibility of the mechanism is confirmed.

  4. DNA electrophoresis through microlithographic arrays

    International Nuclear Information System (INIS)

    Sevick, E.M.; Williams, D.R.M.

    1996-01-01

    Electrophoresis is one of the most widely used techniques in biochemistry and genetics for size-separating charged molecular chains such as DNA or synthetic polyelectrolytes. The separation is achieved by driving the chains through a gel with an external electric field. As a result of the field and the obstacles that the medium provides, the chains have different mobilities and are physically separated after a given process time. The macroscopically observed mobility scales inversely with chain size: small molecules move through the medium quickly while larger molecules move more slowly. However, electrophoresis remains a tool that has yet to be optimised for most efficient size separation of polyelectrolytes, particularly large polyelectrolytes, e.g. DNA in excess of 30-50 kbp. Microlithographic arrays etched with an ordered pattern of obstacles provide an attractive alternative to gel media and provide wider avenues for size separation of polyelectrolytes and promote a better understanding of the separation process. Its advantages over gels are (1) the ordered array is durable and can be re-used, (2) the array morphology is ordered and can be standardized for specific separation, and (3) calibration with a marker polyelectrolyte is not required as the array is reproduced to high precision. Most importantly, the array geometry can be graduated along the chip so as to expand the size-dependent regime over larger chain lengths and postpone saturation. In order to predict the effect of obstacles upon the chain-length dependence in mobility and hence, size separation, we study the dynamics of single chains using theory and simulation. We present recent work describing: 1) the release kinetics of a single DNA molecule hooked around a point, frictionless obstacle and in both weak and strong field limits, 2) the mobility of a chain impinging upon point obstacles in an ordered array of obstacles, demonstrating the wide range of interactions possible between the chain and

  5. Affinity Capillary Electrophoresis – A Powerful Tool to Investigate Biomolecular Interactions

    Czech Academy of Sciences Publication Activity Database

    Kašička, Václav

    2017-01-01

    Roč. 30, č. 5 (2017), s. 248 ISSN 1471-6577 Institutional support: RVO:61388963 Keywords : capillary affinity electrophoresis * biomolecular interactions * binding constants Subject RIV: CB - Analytical Chemistry, Separation OBOR OECD: Analytical chemistry Impact factor: 0.663, year: 2016

  6. Free-zone electrophoresis of animal cells. 1: Experiments on cell-cell interactions

    Science.gov (United States)

    Todd, P. W.; Hjerten, S.

    1985-01-01

    The electrophoretically migrating zones wasa monitored. The absence of fluid flows in the direction of migration permits direct measurement of electrophoretic velocities of any material. Sedimentation is orthogonal to electrokinetic motion and the effects of particle-particle interaction on electrophoretic mobility is studied by free zone electrophoresis. Fixed erythrocytes at high concentrations, mixtures of fixed erythrocytes from different animal species, and mixtures of cultured human cells were studied in low ionic strength buffers. The electrophoretic velocity of fixed erythrocytes was not altered by increasing cell concentration or by the mixing of erythrocytes from different species. When zones containing cultured human glial cells and neuroblastoma cells are permitted to interact during electrophoresis, altered migration patterns occur. It is found that cell-cell interactions depends upon cell type.

  7. Pulsed field gel electrophoresis a practical guide

    CERN Document Server

    Birren, Bruce

    1993-01-01

    Pulsed Field Gel Electrophoresis: A Practical Guide is the first laboratory manual to describe the theory and practice of this technique. Based on the authors' experience developing pulsed field gel instruments and teaching procedures, this book provides everything a researcher or student needs to know in order to understand and carry out pulsed field gel experiments. Clear, well-tested protocols assume only that users have a basic familiarity with molecular biology. Thorough coverage of useful data, theory, and applications ensures that this book is also a lasting resource for more adv

  8. Light emitting diode, photodiode-based fluorescence detection system for DNA analysis with microchip electrophoresis.

    Science.gov (United States)

    Hall, Gordon H; Glerum, D Moira; Backhouse, Christopher J

    2016-02-01

    Electrophoretic separation of fluorescently end-labeled DNA after a PCR serves as a gold standard in genetic diagnostics. Because of their size and cost, instruments for this type of analysis have had limited market uptake, particularly for point-of-care applications. This might be changed through a higher level of system integration and lower instrument costs that can be realized through the use of LEDs for excitation and photodiodes for detection--if they provide sufficient sensitivity. Here, we demonstrate an optimized microchip electrophoresis instrument using polymeric fluidic chips with fluorescence detection of end-labeled DNA with a LOD of 0.15 nM of Alexa Fluor 532. This represents orders of magnitude improvement over previously reported instruments of this type. We demonstrate the system with an electrophoretic separation of two PCR products and their respective primers. We believe that this is the first LED-induced fluorescence microchip electrophoresis system with photodiode-based detection that could be used for standard applications of PCR and electrophoresis. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Immuno-magnetic beads-based extraction-capillary zone electrophoresis-deep UV laser-induced fluorescence analysis of erythropoietin.

    Science.gov (United States)

    Wang, Heye; Dou, Peng; Lü, Chenchen; Liu, Zhen

    2012-07-13

    Erythropoietin (EPO) is an important glycoprotein hormone. Recombinant human EPO (rhEPO) is an important therapeutic drug and can be also used as doping reagent in sports. The analysis of EPO glycoforms in pharmaceutical and sports areas greatly challenges analytical scientists from several aspects, among which sensitive detection and effective and facile sample preparation are two essential issues. Herein, we investigated new possibilities for these two aspects. Deep UV laser-induced fluorescence detection (deep UV-LIF) was established to detect the intrinsic fluorescence of EPO while an immuno-magnetic beads-based extraction (IMBE) was developed to specifically extract EPO glycoforms. Combined with capillary zone electrophoresis (CZE), CZE-deep UV-LIF allows high resolution glycoform profiling with improved sensitivity. The detection sensitivity was improved by one order of magnitude as compared with UV absorbance detection. An additional advantage is that the original glycoform distribution can be completely preserved because no fluorescent labeling is needed. By combining IMBE with CZE-deep UV-LIF, the overall detection sensitivity was 1.5 × 10⁻⁸ mol/L, which was enhanced by two orders of magnitude relative to conventional CZE with UV absorbance detection. It is applicable to the analysis of pharmaceutical preparations of EPO, but the sensitivity is insufficient for the anti-doping analysis of EPO in blood and urine. IMBE can be straightforward and effective approach for sample preparation. However, antibodies with high specificity were the key for application to urine samples because some urinary proteins can severely interfere the immuno-extraction. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. Transient isotachophoresis in carrier ampholyte-based capillary electrophoresis for protein analysis

    Czech Academy of Sciences Publication Activity Database

    Busnel, J. M.; Descroix, S.; Godfrin, D.; Hennion, M. C.; Kašička, Václav; Peltre, G.

    2006-01-01

    Roč. 27, č. 18 (2006), s. 3591-3598 ISSN 0173-0835 Institutional research plan: CEZ:AV0Z40550506 Keywords : carrier ampholyte-based capillary electrophoresis * transient isotachophoresis * proteins Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 4.101, year: 2006

  11. Isolation of monodisperse nanodisc-reconstituted membrane proteins using free flow electrophoresis

    DEFF Research Database (Denmark)

    Justesen, Bo Højen; Laursen, Tomas; Weber, Gerhard

    2013-01-01

    Free flow electrophoresis is used for rapid and high-recovery isolation of homogeneous preparations of functionally active membrane proteins inserted into nanodiscs. The approach enables isolation of integral and membrane anchored proteins and is also applicable following introduction of, e...

  12. 24 CFR 206.115 - [Reserved

    Science.gov (United States)

    2010-04-01

    ... MORTGAGE AND LOAN INSURANCE PROGRAMS UNDER NATIONAL HOUSING ACT AND OTHER AUTHORITIES HOME EQUITY CONVERSION MORTGAGE INSURANCE Contract Rights and Obligations Mortgage Insurance Premiums § 206.115 [Reserved] ...

  13. Alkaline gel electrophoresis assay to detect DNA strand breaks and repair mechanisms in Escherichia coli

    International Nuclear Information System (INIS)

    Mattos, Jose Carlos Pelielo de; Motta, Ellen Serri da; Oliveira, Marcia Betania Nunes de; Dantas, Flavio Jose da Silva; Araujo, Adriano Caldeira de

    2008-01-01

    Reactive oxygen species (ROS) can induce lesions in different cellular targets, including DNA. Stannous chloride (SnCl 2 ) is a ROS generator, leading to lethality in Escherichia coli (E. coli), with the base excision repair (BER) mechanism playing a role in this process. Many techniques have been developed to detect genotoxicity, as comet assay, in eukaryotic cells, and plasmid DNA agarose gel electrophoresis. In this study, an adaptation of the alkaline gel electrophoresis method was carried out to ascertain the induction of strand breaks by SnCl 2 in bacterial DNA, from E. coli BER mutants, and its repair pathway. Results obtained show that SnCl 2 was able to induce DNA strand breaks in all strains tested. Moreover, endonuclease IV and exonuclease III play a role in DNA repair. On the whole, data has shown that the alkaline gel electrophoresis assay could be used both for studying DNA strand breaks induction and for associated repair mechanisms. (author)

  14. Alkaline gel electrophoresis assay to detect DNA strand breaks and repair mechanisms in Escherichia coli

    Energy Technology Data Exchange (ETDEWEB)

    Mattos, Jose Carlos Pelielo de; Motta, Ellen Serri da; Oliveira, Marcia Betania Nunes de; Dantas, Flavio Jose da Silva; Araujo, Adriano Caldeira de [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Dept. de Biofisica e Biometria. Lab. de Radio e Fotobiologia]. E-mail: jcmattos@uerj.br

    2008-12-15

    Reactive oxygen species (ROS) can induce lesions in different cellular targets, including DNA. Stannous chloride (SnCl{sub 2}) is a ROS generator, leading to lethality in Escherichia coli (E. coli), with the base excision repair (BER) mechanism playing a role in this process. Many techniques have been developed to detect genotoxicity, as comet assay, in eukaryotic cells, and plasmid DNA agarose gel electrophoresis. In this study, an adaptation of the alkaline gel electrophoresis method was carried out to ascertain the induction of strand breaks by SnCl{sub 2} in bacterial DNA, from E. coli BER mutants, and its repair pathway. Results obtained show that SnCl{sub 2} was able to induce DNA strand breaks in all strains tested. Moreover, endonuclease IV and exonuclease III play a role in DNA repair. On the whole, data has shown that the alkaline gel electrophoresis assay could be used both for studying DNA strand breaks induction and for associated repair mechanisms. (author)

  15. Tilted hexagonal post arrays: DNA electrophoresis in anisotropic media.

    Science.gov (United States)

    Chen, Zhen; Dorfman, Kevin D

    2014-02-01

    Using Brownian dynamics simulations, we show that DNA electrophoresis in a hexagonal array of micron-sized posts changes qualitatively when the applied electric field vector is not coincident with the lattice vectors of the array. DNA electrophoresis in such "tilted" post arrays is superior to the standard "un-tilted" approach; while the time required to achieve a resolution of unity in a tilted post array is similar to an un-tilted array at a low-electric field strengths, this time (i) decreases exponentially with electric field strength in a tilted array and (ii) increases exponentially with electric field strength in an un-tilted array. Although the DNA dynamics in a post array are complicated, the electrophoretic mobility results indicate that the "free path," i.e. the average distance of ballistic trajectories of point-sized particles launched from random positions in the unit cell until they intersect the next post, is a useful proxy for the detailed DNA trajectories. The analysis of the free path reveals a fundamental connection between anisotropy of the medium and DNA transport therein that goes beyond simply improving the separation device. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Combined use of [TBA][L-ASP] and hydroxypropyl-β-cyclodextrin as selectors for separation of Cinchona alkaloids by capillary electrophoresis.

    Science.gov (United States)

    Zhang, Yu; Yu, Haixia; Wu, Yujiao; Zhao, Wenyan; Yang, Min; Jing, Huanwang; Chen, Anjia

    2014-10-01

    In this paper, a new capillary electrophoresis (CE) separation and detection method was developed for the chiral separation of the four major Cinchona alkaloids (quinine/quinidine and cinchonine/cinchonidine) using hydroxypropyl-β-cyclodextrin (HP-β-CD) and chiral ionic liquid ([TBA][L-ASP]) as selectors. Separation parameters such as buffer concentrations, pH, HP-β-CD and chiral ionic liquid concentrations, capillary temperature, and separation voltage were investigated. After optimization of separation conditions, baseline separation of the three analytes (cinchonidine, quinine, cinchonine) was achieved in fewer than 7 min in ammonium acetate background electrolyte (pH 5.0) with the addition of HP-β-CD in a concentration of 40 mM and [TBA][L-ASP] of 14 mM, while the baseline separation of cinchonine and quinidine was not obtained. Therefore, the first-order derivative electropherogram was applied for resolving overlapping peaks. Regression equations revealed a good linear relationship between peak areas in first-order derivative electropherograms and concentrations of the two diastereomer pairs. The results not only indicated that the first-order derivative electropherogram was effective in determination of a low content component and of those not fully separated from adjacent ones, but also showed that the ionic liquid appeared to be a very promising chiral selector in CE. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. On-line sequential injection-capillary electrophoresis for near-real-time monitoring of extracellular lactate in cell culture flasks.

    Science.gov (United States)

    Alhusban, Ala A; Gaudry, Adam J; Breadmore, Michael C; Gueven, Nuri; Guijt, Rosanne M

    2014-01-03

    Cell culture has replaced many in vivo studies because of ethical and regulatory measures as well as the possibility of increased throughput. Analytical assays to determine (bio)chemical changes are often based on end-point measurements rather than on a series of sequential determinations. The purpose of this work is to develop an analytical system for monitoring cell culture based on sequential injection-capillary electrophoresis (SI-CE) with capacitively coupled contactless conductivity detection (C(4)D). The system was applied for monitoring lactate production, an important metabolic indicator, during mammalian cell culture. Using a background electrolyte consisting of 25mM tris(hydroxymethyl)aminomethane, 35mM cyclohexyl-2-aminoethanesulfonic acid with 0.02% poly(ethyleneimine) (PEI) at pH 8.65 and a multilayer polymer coated capillary, lactate could be resolved from other compounds present in media with relative standard deviations 0.07% for intraday electrophoretic mobility and an analysis time of less than 10min. Using the human embryonic kidney cell line HEK293, lactate concentrations in the cell culture medium were measured every 20min over 3 days, requiring only 8.73μL of sample per run. Combining simplicity, portability, automation, high sample throughput, low limits of detection, low sample consumption and the ability to up- and outscale, this new methodology represents a promising technique for near real-time monitoring of chemical changes in diverse cell culture applications. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Ergot alkaloids as chiral selectors in capillary electrophoresis and other electromigration methods

    Czech Academy of Sciences Publication Activity Database

    Sinibaldi, M.; Messina, A.; Stodůlková, Eva; Flieger, Miroslav

    2010-01-01

    Roč. 1, č. 3 (2010), s. 233-243 ISSN 0976-5514 Institutional research plan: CEZ:AV0Z50200510 Keywords : capillary electrophoresis * capillary electrochromatography * chiral analysis Subject RIV: CB - Analytical Chemistry, Separation

  19. HIV and serum protein electrophoresis patterns in KwaZulu-Natal: a ...

    African Journals Online (AJOL)

    Objective. To describe the effect of HIV serostatus on serum proteins, serum protein electrophoresis (SPEP) patterns and monoclonal bands. Setting. Inkosi Albert Luthuli Central Hospital, Durban. Design. Retrospective, anonymous analysis of routine laboratory results. Results. Monoclonal bands were not increased in ...

  20. Electrophoresis today and tomorrow: helping biologists’ dreams come true

    Czech Academy of Sciences Publication Activity Database

    Klepárník, Karel; Boček, Petr

    2010-01-01

    Roč. 32, č. 3 (2010), s. 218-226 ISSN 0265-9247 R&D Projects: GA ČR GA203/08/1536; GA AV ČR IAA400310609; GA AV ČR IAA400310703; GA AV ČR KAN400310651 Institutional research plan: CEZ:AV0Z40310501 Keywords : capillary electrophoresis * isoelectric focusing * isotachophoresis Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 4.479, year: 2010

  1. Separation of intron 22 inversion type 1 and 2 of hemophilia A by modified inverse-shifting polymerase chain reaction and capillary gel electrophoresis.

    Science.gov (United States)

    Pan, Tzu-Yu; Chiou, Shyh-Shin; Wang, Chun-Chi; Wu, Shou-Mei

    2014-12-01

    An inverse-shifting polymerase chain reaction (IS-PCR) combined with short-end capillary gel electrophoresis (CGE) was developed for genotyping of intron 22 inversion Type 1 (Inv22-1) and Type 2 (Inv22-2) of hemophilia A (HA). Severe HA cases are affected by intron 22 inversion around 45-50%. Inv22-1 has higher frequency than Inv22-2. The aim of this study is to distinguish them by genotyping. In order to improve Inv22 genotyping efficiency, five primers were designed and applied to differentiate the wild type, Inv22-1, Inv22-2 and carrier. Three amplicons of 405, 457 and 512 bp were recognized for wild type; 333, 457 and 584 bp for Inv22-1; 385, 405 and 584 bp for Inv22-2. The Inv22-1 carrier has 5 amplicons including 333, 405, 457, 512, 584 bp and Inv22-2 carrier is differentiated by 385, 405, 457, 512 and 584 bp. The amplicons between Inv22-1 and Inv22-2 carriers are only different in 333 bp for Inv22-1 carrier and 385 bp for Inv22-2 carrier. Capillary gel electrophoresis (CGE) was used for separation within 5 min. The separation voltage was set at 8 kV (cathode at detector), and the temperature was kept at 25°C. The sieving matrix was 89 mM Tris, 89 mM boric acid, 2mM EDTA containing 0.4% (w/v) HPMC and 1 μM of YO-PRO(®)-1 Iodide. Total of 50 HA patients (including 35 non-Inv22, 14 Inv22-1, and one Inv22-2 patients) and 7 HA carriers were diagnosed in the application. Seven random samples (5 patients and 2 carriers) were subjected to comparison and gave identical results of DNA sequencing and this modified IS-PCR. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Multi-immunoreaction-based dual-color capillary electrophoresis for enhanced diagnostic reliability of thyroid gland disease.

    Science.gov (United States)

    Woo, Nain; Kim, Su-Kang; Kang, Seong Ho

    2017-08-04

    Thyroid-stimulating hormone (TSH) secretion plays a critical role in regulating thyroid gland function and circulating thyroid hormones (i.e., thyroxine (T4) and triiodothyronine (T3)). A novel multi-immunoreaction-based dual-color capillary electrophoresis (CE) technique was investigated in this study to assess its reliability in diagnosing thyroid gland disease via simultaneous detection of TSH, T3, and T4 in a single run of CE. Compared to the conventional immunoreaction technique, multi-immunoreaction of biotinylated streptavidin antibodies increased the selectivity and sensitivity for individual hormones in human blood samples. Dual-color laser-induced fluorescence (LIF) detection-based CE performed in a running buffer of 25mM Na 2 B 4 O 7 -NaOH (pH 9.3) allowed for fast, simultaneous quantitative analysis of three target thyroid hormones using different excited wavelengths within 3.2min. This process had excellent sensitivity and detection limits of 0.05-5.32 fM. The results showed 1000-100,000 times higher detection sensitivity than previous methods. Method validation with enzyme linked immunosorbent assay for application with human blood samples showed that the CE method was not significantly different at the 98% confidence level. Therefore, the developed CE-LIF method has the advantages of high detection sensitivity, faster analysis time, and smaller sample amount compared to the conventional methods The combined multi-immunoreaction and dual-color CE-LIF method should have increased diagnostic reliability for thyroid gland disease compared to conventional methods based on its highly sensitive detection of thyroid hormones using a single injection and high-throughput screening. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Increase in local protein concentration by field-inversion gel electrophoresis

    Directory of Open Access Journals (Sweden)

    Paulus Aran

    2007-09-01

    Full Text Available Abstract Background Proteins that migrate through cross-linked polyacrylamide gels (PAGs under the influence of a constant electric field experience negative factors, such as diffusion and non-specific trapping in the gel matrix. These negative factors reduce protein concentrations within a defined gel volume with increasing migration distance and, therefore, decrease protein separation efficiency. Enhancement of protein separation efficiency was investigated by implementing pulsed field-inversion gel electrophoresis (FIGE. Results Separation of model protein species and large protein complexes was compared between FIGE and constant field electrophoresis (CFE in different percentages of PAGs. Band intensities of proteins in FIGE with appropriate ratios of forward and backward pulse times were superior to CFE despite longer running times. These results revealed an increase in band intensity per defined gel volume. A biphasic protein relative mobility shift was observed in percentages of PAGs up to 14%. However, the effect of FIGE on protein separation was stochastic at higher PAG percentage. Rat liver lysates subjected to FIGE in the second-dimension separation of two-dimensional polyarcylamide gel electrophoresis (2D PAGE showed a 20% increase in the number of discernible spots compared with CFE. Nine common spots from both FIGE and CFE were selected for peptide sequencing by mass spectrometry (MS, which revealed higher final ion scores of all nine protein spots from FIGE. Native protein complexes ranging from 800 kDa to larger than 2000 kDa became apparent using FIGE compared with CFE. Conclusion The present investigation suggests that FIGE under appropriate conditions improves protein separation efficiency during PAGE as a result of increased local protein concentration. FIGE can be implemented with minimal additional instrumentation in any laboratory setting. Despite the tradeoff of longer running times, FIGE can be a powerful protein

  4. Increase in local protein concentration by field-inversion gel electrophoresis.

    Science.gov (United States)

    Tsai, Henghang; Low, Teck Yew; Freeby, Steve; Paulus, Aran; Ramnarayanan, Kalpana; Cheng, Chung-Pui Paul; Leung, Hon-Chiu Eastwood

    2007-09-26

    Proteins that migrate through cross-linked polyacrylamide gels (PAGs) under the influence of a constant electric field experience negative factors, such as diffusion and non-specific trapping in the gel matrix. These negative factors reduce protein concentrations within a defined gel volume with increasing migration distance and, therefore, decrease protein separation efficiency. Enhancement of protein separation efficiency was investigated by implementing pulsed field-inversion gel electrophoresis (FIGE). Separation of model protein species and large protein complexes was compared between FIGE and constant field electrophoresis (CFE) in different percentages of PAGs. Band intensities of proteins in FIGE with appropriate ratios of forward and backward pulse times were superior to CFE despite longer running times. These results revealed an increase in band intensity per defined gel volume. A biphasic protein relative mobility shift was observed in percentages of PAGs up to 14%. However, the effect of FIGE on protein separation was stochastic at higher PAG percentage. Rat liver lysates subjected to FIGE in the second-dimension separation of two-dimensional polyarcylamide gel electrophoresis (2D PAGE) showed a 20% increase in the number of discernible spots compared with CFE. Nine common spots from both FIGE and CFE were selected for peptide sequencing by mass spectrometry (MS), which revealed higher final ion scores of all nine protein spots from FIGE. Native protein complexes ranging from 800 kDa to larger than 2000 kDa became apparent using FIGE compared with CFE. The present investigation suggests that FIGE under appropriate conditions improves protein separation efficiency during PAGE as a result of increased local protein concentration. FIGE can be implemented with minimal additional instrumentation in any laboratory setting. Despite the tradeoff of longer running times, FIGE can be a powerful protein separation tool.

  5. Rapid monitoring of autolysis process of proteases by capillary electrophoresis.

    Science.gov (United States)

    Chen, Xiu-Lan; Shun, Cai-Yun; Zhang, Yu-Zhong; Gao, Pei-Ji

    2003-10-01

    A protease, MCP-01, produced by a deep-sea psychrotrophic strain of Pseudoaltermonas sp. SM9913 was purified and its autolysis reaction at 20 degrees C-50 degrees C was monitored by capillary electrophoresis. Capillary electrophoresis provides a rapid assay because the degree and state of autolysis of protease MCP-01 could be observed within 6 min. The autolysis rate increased as the temperature rose in the tested range. After 30 min incubation at 30 degrees C, 77% of MCP-01 autolyzed into peptides. However, its activity for the hydrolysis of casein was reduced by only 4%. The rate of loss of activity of MCP-01 was thus slower than that of autolysis of MCP-01 at 30 degrees C. Similar results were obtained when MCP-01 was incubated at 20 degrees C, 40 degrees C and 50 degrees C. Large peptides produced by autolysis of MCP-01 therefore still have catalytic activity. When these large peptides autolyzed further into smaller peptides, the enzyme conformation that retained its catalytic activity was destroyed and activity was lost.

  6. Acetic acid denaturing pulsed field capillary electrophoresis for RNA separation.

    Science.gov (United States)

    Li, Zhenqing; Dou, Xiaoming; Ni, Yi; Sumitomo, Keiko; Yamaguchi, Yoshinori

    2010-10-01

    Based on our previous work of in-capillary denaturing polymer electrophoresis, we present a study of RNA molecular separation up to 6.0 kilo nucleotide by pulsed field CE. This is the first systematic investigation of electrophoresis of a larger molecular mass RNA in linear hydroxyethylcellulose (HEC) under pulsed field conditions. The parameters that may influence the separation performance, e.g. gel polymer concentration, modulation depth and pulse frequency, are analyzed in terms of resolution and mobility. For denaturing and separating RNA in the capillary simultaneously, 2 M acetic acid was added into the HEC polymer to serve as separation buffer. Result shows that (i) in pulsed field conditions, RNA separation can be achieved in a wide range of concentration of HEC polymer, and RNA fragments between 0.3 and 0.6 kilo nucleotide are sensitive to the polymer concentration; (ii) under certain pulsed field conditions, RNA fragments move linearly as the modulation depth increases; (iii) 12.5 Hz is the resonance frequency for RNA reorientation time and applied frequency.

  7. Simplification and improvement of protein detection in two-dimensional electrophoresis gels with SERVA HPE™ lightning red.

    Science.gov (United States)

    Griebel, Anja; Obermaier, Christian; Westermeier, Reiner; Moche, Martin; Büttner, Knut

    2013-07-01

    A new fluorescent amino-reactive dye has been tested for both labelling proteins prior to electrophoretic separations and between the two steps of two-dimensional electrophoresis. A series of experiments showed, that the labelling of lysines with this dye is compatible with all standard additives used for sample preparation, including reducing substances and carrier ampholytes. Using this dye for pre-labelling considerably simplifies the electrophoresis and detection workflow and provides highly sensitive and quantitative visualisation of proteins.

  8. Horseradish peroxidase and antibody labeled gold nanoparticle probe for amplified immunoassay of ciguatoxin in fish samples based on capillary electrophoresis with electrochemical detection.

    Science.gov (United States)

    Zhang, Zhaoxiang; Liu, Ying; Zhang, Chaoying; Luan, Wenxiu

    2015-03-01

    This paper describes a new amplified immunoassay with horseradish peroxidase (HRP) and antibody (Ab) labeled gold nanoparticles (AuNPs) probe hyphenated to capillary electrophoresis (CE) with electrochemical (EC) detection for ultrasensitive determination of ciguatoxin CTX1B. AuNPs were conjugated with HRP and Ab, and then incubated with limited amount of CTX1B to produce immunocomplex. The immunoreactive sample was injected into capillary for CE separation and EC detection. Enhanced sensitivity was obtained by adopting the AuNPs as carriers of HRP and Ab at high HRP/Ab molar ratio. The calibration curve of CTX1B was in the range of 0.06-90 ng/mL. The detection limit was 0.045 ng/mL, which is 38-fold lower than that of HPLC-MS method for CTX1B analysis. The proposed method was successfully applied for the quantification of CTX1B in contamined fish samples by simultaneously labeling Ab and HRP on AuNPs. The amplified IA with HRP and Ab labeled AuNPs probe hyphenated to CE and EC detection provides a sensitive analytical approach for the determination of trace ciguatoxin in complex samples. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Approach to the profiling and characterization of influenza vaccine constituents by the combined use of size-exclusion chromatography, gel electrophoresis and mass spectrometry.

    Science.gov (United States)

    Garcia-Cañas, Virginia; Lorbetskie, Barry; Cyr, Terry D; Hefford, Mary A; Smith, Sophie; Girard, Michel

    2010-03-01

    A combination of separation and identification techniques was used to rapidly and reproducibly analyze influenza vaccine constituents. Size-exclusion HPLC analysis reduced significantly the complexity by providing a constituents profile according to size. Significantly, no sample treatment was required prior to analysis thus eliminating a potential source of artifacts and degradation. Distinct profiles were associated with influenza strains as well as with vaccines from different manufacturers. Samples analyzed over several years allowed evaluation of method performance and provided stability-indicating data relating to the structural integrity of separated components. Collected chromatographic peaks were identified by gel electrophoresis and MALDI/MS of tryptic digests from excised gel bands. The challenge in obtaining high quality analytical data from complex mixtures clearly demonstrated the value of separation steps prior to MS identification. The method presented here is not intended to replace existing methodology; it is intended to provide a product specific profile to be used as a rapid screen for manufacturer, year (for annual influenza vaccines), stability or counterfeit product. It is a new screening method that provides a rapid and robust indication of products which require further investigation as a result of a deviation in their characteristic profile. Until now this tool did not exist. (c) 2009. Published by Elsevier Ltd. All rights reserved.

  10. Multilocus sequence typing scheme versus pulsed-field gel electrophoresis for typing Mycobacterium abscessus isolates.

    Science.gov (United States)

    Machado, Gabriel Esquitini; Matsumoto, Cristianne Kayoko; Chimara, Erica; Duarte, Rafael da Silva; de Freitas, Denise; Palaci, Moises; Hadad, David Jamil; Lima, Karla Valéria Batista; Lopes, Maria Luiza; Ramos, Jesus Pais; Campos, Carlos Eduardo; Caldas, Paulo César; Heym, Beate; Leão, Sylvia Cardoso

    2014-08-01

    Outbreaks of infections by rapidly growing mycobacteria following invasive procedures, such as ophthalmological, laparoscopic, arthroscopic, plastic, and cardiac surgeries, mesotherapy, and vaccination, have been detected in Brazil since 1998. Members of the Mycobacterium chelonae-Mycobacterium abscessus group have caused most of these outbreaks. As part of an epidemiological investigation, the isolates were typed by pulsed-field gel electrophoresis (PFGE). In this project, we performed a large-scale comparison of PFGE profiles with the results of a recently developed multilocus sequence typing (MLST) scheme for M. abscessus. Ninety-three isolates were analyzed, with 40 M. abscessus subsp. abscessus isolates, 47 M. abscessus subsp. bolletii isolates, and six isolates with no assigned subspecies. Forty-five isolates were obtained during five outbreaks, and 48 were sporadic isolates that were not associated with outbreaks. For MLST, seven housekeeping genes (argH, cya, glpK, gnd, murC, pta, and purH) were sequenced, and each isolate was assigned a sequence type (ST) from the combination of obtained alleles. The PFGE patterns of DraI-digested DNA were compared with the MLST results. All isolates were analyzable by both methods. Isolates from monoclonal outbreaks showed unique STs and indistinguishable or very similar PFGE patterns. Thirty-three STs and 49 unique PFGE patterns were identified among the 93 isolates. The Simpson's index of diversity values for MLST and PFGE were 0.69 and 0.93, respectively, for M. abscessus subsp. abscessus and 0.96 and 0.97, respectively, for M. abscessus subsp. bolletii. In conclusion, the MLST scheme showed 100% typeability and grouped monoclonal outbreak isolates in agreement with PFGE, but it was less discriminative than PFGE for M. abscessus. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  11. Capillary electrophoresis fragment analysis and clone sequencing in detection of dynamic mutations of spinocerebellar ataxia

    Directory of Open Access Journals (Sweden)

    Yuan-yuan CHEN

    2018-04-01

    Full Text Available Objective To estimate the accuracy and stability of capillary electrophoresis fragment analysis and clone sequencing in detecting dynamic mutations of spinocerebellar ataxia (SCA. Methods Capillary electrophoresis fragment analysis and clone sequencing were used in detecting trinucleotide repeated sequence of 14 SCA patients (3 cases of SCA2, 2 cases of SCA7, 7 cases of SCA8 and 2 cases of SCA17. Results Capillary electrophoresis fragment analysis of 3 SCA2 cases showed the expanded cytosine-adenine-guanine (CAG repeats were 31, 30 and 32, and the copy numbers of 3 clone sequencing for 3 colonies in each case were 37/40/40, 37/38/39 and 38/39/40 respectively. Capillary electrophoresis fragment analysis of 2 SCA7 cases showed the expanded CAG repeats were 57 and 34, and the copy numbers of repeats were 69, 74, 75 in 3 colonies of one case, and was 45 in the other case. For the 7 SCA8 cases with the expanded cytosine-thymine-adenine (CTA/cytosine-thymine-guanine (CTG repeats of 99, 111, 104, 92, 89, 104 and 75, the results of clone sequencing were 97, 116, 104, 90, 90, 102 and 76 respectively. For 2 SCA17 cases with the short/expanded CAG repeats of 37/50 and 36/45, the results of clone sequencing were 51/50/52 and 45/44 for 3 and 2 colonies. Conclusions Although the higher mobility of polymerase chain reaction (PCR products containing dynamic mutation in the capillary electrophoresis fragment analysis might cause the deviation for analysis of copy numbers, the deviation was predictable and the results were repeatable. The clone sequencing results showed obvious instability, especially for SCA2 and SCA7 genes, which might owing to their simple CAG repeats. Consequently, clone sequencing is not suited for detection of dynamic mutation, not to mention the quantitative criteria of dynamic mutation sequencing. DOI: 10.3969/j.issn.1672-6731.2018.03.008

  12. Choice of capillary electrophoresis systems for the impurity profiling of drugs

    NARCIS (Netherlands)

    Hilhorst, M.J; Somsen, G.W; de Jong, G.J.

    In order to develop a strategy for the impurity profiling of drugs, the possibilities of some capillary electrophoresis systems were investigated. A mixture containing a drug and some of its possible impurities has been used as a model problem. The test compounds were investigated by capillary zone

  13. Self-aligning subatmospheric hybrid liquid junction electrospray interface for capillary electrophoresis

    Czech Academy of Sciences Publication Activity Database

    Křenková, Jana; Klepárník, Karel; Grym, Jakub; Luksch, Jaroslav; Foret, František

    2016-01-01

    Roč. 37, č. 3 (2016), s. 414-417 ISSN 0173-0835 R&D Projects: GA ČR(CZ) GBP206/12/G014 Institutional support: RVO:68081715 Keywords : capillary electrophoresis * electrospray interfacing * microfabrication Subject RIV: CB - Analytical Chemistry , Separation Impact factor: 2.744, year: 2016

  14. Electrohydrodynamics and other hydrodynamic phenomena in continuous-flow electrophoresis

    International Nuclear Information System (INIS)

    Saville, D.A.

    1982-01-01

    The process known as continuous flow electrophoresis employs an electric field to separate the constituents of particulate samples suspended in a liquid. Complications arise because the electric field generates temperature gradients due to Joule heating and derives an electrohydrodynamic crossflow. Several aspects of the flow are discussed including entrance effects, hydrodynamic stability and a flow restructuring due to the combined effects of buoyancy and the crossflow. 10 references

  15. Salmonella enterica pulsed-field gel electrophoresis clusters, Minnesota, USA, 2001-2007.

    Science.gov (United States)

    Rounds, Joshua M; Hedberg, Craig W; Meyer, Stephanie; Boxrud, David J; Smith, Kirk E

    2010-11-01

    We determined characteristics of Salmonella enterica pulsed-field gel electrophoresis clusters that predict their being solved (i.e., that result in identification of a confirmed outbreak). Clusters were investigated by the Minnesota Department of Health by using a dynamic iterative model. During 2001-2007, a total of 43 (12.5%) of 344 clusters were solved. Clusters of ≥4 isolates were more likely to be solved than clusters of 2 isolates. Clusters in which the first 3 case isolates were received at the Minnesota Department of Health within 7 days were more likely to be solved than were clusters in which the first 3 case isolates were received over a period >14 days. If resources do not permit investigation of all S. enterica pulsed-field gel electrophoresis clusters, investigation of clusters of ≥4 cases and clusters in which the first 3 case isolates were received at a public health laboratory within 7 days may improve outbreak investigations.

  16. Proteomic analysis of plasma proteins in diabetic retinopathy patients by two dimensional electrophoresis and MALDI-Tof-MS.

    Science.gov (United States)

    Gopalakrishnan, Vidhya; Purushothaman, Parthiban; Bhaskar, Anusha

    2015-01-01

    Diabetic retinopathy is a highly specific vascular complication of diabetes mellitus and progresses from mild non-proliferative abnormalities characterized by increased vascular permeability to moderate and severe proliferative diabetic retinopathy characterized by the growth of blood vessels on the retina. The aim of the study was to identify the differentially expressed proteins in diabetic retinopathy using two-dimensional electrophoresis. Blood sample was drawn from subjects with diabetes mellitus (without retinopathy) who served as controls and patients with diabetic retinopathy in tubes containing EDTA as anticoagulant. Albumin and immunoglobulin IgG collectively removed to enrich proteins of lower abundance. 2de was carried out to see if there are any differentially expressed proteins. Approximately 48 and 61 spots were identified in control and diabetic retinopathy respectively, of which three protein spots RBP1 (retinol-binding protein 1), NUD10 (Diphosphoinositol polyphosphohydrolase 3 alpha), NGB (neuroglobin) were down regulated and HBG2 (hemoglobin) and BY55 (CD 160 antigen) were upregulated in diabetic retinopathy. These five protein spots were excised and were subjected to in-gel tryptic digestion, and their identities were determined by ultraflex MALDI-TOF-MS. We report a comprehensive patient-based plasma proteomic approach to the identification of potential biomarkers for diabetic retinopathy screening and detection. We identified 5 different proteins that were differentially expressed in the plasma of control diabetic patients (without retinopathy). Among these five proteins the expression of neuroglobin (NGB) protein varied significantly and may be a potential biomarker in diabetic retinopathy. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Fluid mechanics of electroosmotic flow and its effect on band broadening in capillary electrophoresis.

    Science.gov (United States)

    Ghosal, Sandip

    2004-01-01

    Electroosmotic flow (EOF) usually accompanies electrophoretic migration of charged species in capillary electrophoresis unless special precautions are taken to suppress it. The presence of the EOF provides certain advantages in separations. It is an alternative to mechanical pumps, which are inefficient and difficult to build at small scales, for transporting reagents and analytes on microfluidic chips. The downside is that any imperfection that distorts the EOF profile reduces the separation efficiency. In this paper, the basic facts about EOF are reviewed from the perspective of fluid mechanics and its effect on separations in free solution capillary zone electrophoresis is discussed in the light of recent advances.

  18. Ocular Proteomics with Emphasis on Two-Dimensional Gel Electrophoresis and Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Honoré Bent

    2010-01-01

    Full Text Available Abstract The intention of this review is to provide an overview of current methodologies employed in the rapidly developing field of ocular proteomics with emphasis on sample preparation, two-dimensional polyacrylamide gel electrophoresis (2D-PAGE and mass spectrometry (MS. Appropriate sample preparation for the diverse range of cells and tissues of the eye is essential to ensure reliable results. Current methods of protein staining for 2D-PAGE, protein labelling for two-dimensional difference gel electrophoresis, gel-based expression analysis and protein identification by MS are summarised. The uses of gel-free MS-based strategies (MuDPIT, iTRAQ, ICAT and SILAC are also discussed. Proteomic technologies promise to shed new light onto ocular disease processes that could lead to the discovery of strong novel biomarkers and therapeutic targets useful in many ophthalmic conditions.

  19. Injections from sub-μL sample volumes in commercial capillary electrophoresis

    Czech Academy of Sciences Publication Activity Database

    Šlampová, Andrea; Kubáň, Pavel

    2017-01-01

    Roč. 1497, MAY (2017), s. 164-171 ISSN 0021-9673 R&D Projects: GA ČR(CZ) GA16-09135S Institutional support: RVO:68081715 Keywords : capillary electrophoresis * microinjections * contactless conductivity detection Subject RIV: CB - Analytical Chemistry, Separation OBOR OECD: Analytical chemistry Impact factor: 3.981, year: 2016

  20. High lane density slab-gel electrophoresis using micromachined instrumentation.

    Science.gov (United States)

    Papautsky, I; Mohanty, S; Weiss, R; Frazier, A B

    2001-10-01

    In this paper, micromachined pipette arrays (MPAs) and microcombs were studied as a means of enabling high lane density gel electrophoresis. The MPA provide a miniaturized format to interface sub-microliter volumes of samples between macroscale sample preparation formats and microscale biochemical analysis systems. The microcombs provide a means of creating sample loading wells in the gel material on the same center-to-center spacing as the MPAs. Together, the two micromachined instruments provide an alternative to current combs and pipetting technologies used for creating sample loading wells and sample delivery in gel electrophoresis systems. Using three designs for the microcomb-MPA pair, center-to-center spacings of 1.0 mm, 500 microm, and 250 microm are studied. The results demonstrate an approximate 10-fold increase in lane density and a 10-fold reduction in sample size from 5 microL to 500 pL. As a result, the number of theoretical plates has increased 2.5-fold, while system resolution has increased 1.5-fold over the conventional agarose gel systems. An examination of changes in resolution across the width of individual separation lanes in both systems revealed dependence in the case of the conventional gels and no dependence for the gels loaded with the micromachined instrumentation.

  1. Research Article. The Influence of Some Parameters on Chiral Separation of Ibuprofen by High-Performance Liquid Chromatography and Capillary Electrophoresis

    Directory of Open Access Journals (Sweden)

    Balint Alina

    2017-03-01

    Full Text Available Objective: The aim of the study was to compare the influence of mobile phase composition and temperature on chiral separation of racemic ibuprofen by capillary electrophoresis and high performance liquid chromatography with UV detection. Materials and methods: Racemic ibuprofen was analysed on a chiral OVM column with an HPLC system 1100 Agilent Technologies, under isocratic elution, by using potassium dihydrogen phosphate 20 mM and ethanol in mobile phase. The flow rate was set at 1 mL/min, UV detector at 220 nm and different column temperatures were tested. For electrophoresis separation an Agilent CE G1600AX Capillary Electrophoresis System system, with UV detection, was used. The electrophoresis analysis was performed at different pH values and temperatures, with phosphate buffer 25 mM and methyl-β-cyclodextrin as chiral selector. Results: The chromatograhic analysis reveals a high influence of mobile phase pH on ibuprofen enantiomers separation. An elution with a mixture of potassium dihydrogen phosphate 20 mM pH=3 and ethanol, at 25°C, allowed enantiomers separation with good resolution in less than 8 min. Conclusions: The proposed HPLC method proved suitable for the separation of ibuprofen enantiomers with a good resolution, but the capillary electrophoresis tested parameters did not allow chiral discrimination.

  2. A Novel Strategy for Characterization of Glycosylated Proteins Separated by Gel Electrophoresis

    DEFF Research Database (Denmark)

    Larsen, Martin; Skottrup, Peter; Enghild, Jan J.

    2005-01-01

    . We present a new technique, which allows full characterization of low amounts of glycoproteins separated by gel electrophoresis. The method takes advantage of sequential specific and non-specific enzymatic treatment, followed by selective purification and characterization of the glycopeptides using...

  3. Sheathless interface for coupling capillary electrophoresis with mass spectrometry

    Science.gov (United States)

    Wang, Chenchen; Tang, Keqi; Smith, Richard D.

    2014-06-17

    A sheathless interface for coupling capillary electrophoresis (CE) with mass spectrometry is disclosed. The sheathless interface includes a separation capillary for performing CE separation and an emitter capillary for electrospray ionization. A portion of the emitter capillary is porous or, alternatively, is coated to form an electrically conductive surface. A section of the emitter capillary is disposed within the separation capillary, forming a joint. A metal tube, containing a conductive liquid, encloses the joint.

  4. Capillary gel electrophoresis for rapid, high resolution DNA sequencing.

    OpenAIRE

    Swerdlow, H; Gesteland, R

    1990-01-01

    Capillary gel electrophoresis has been demonstrated for the separation and detection of DNA sequencing samples. Enzymatic dideoxy nucleotide chain termination was employed, using fluorescently tagged oligonucleotide primers and laser based on-column detection (limit of detection is 6,000 molecules per peak). Capillary gel separations were shown to be three times faster, with better resolution (2.4 x), and higher separation efficiency (5.4 x) than a conventional automated slab gel DNA sequenci...

  5. Enantioseparation of dansyl amino acids and dipeptides by chiral ligand exchange capillary electrophoresis based on Zn(II)-L-hydroxyproline complexes coordinating with γ-cyclodextrins.

    Science.gov (United States)

    Mu, Xiaoyu; Qi, Li; Qiao, Juan; Yang, Xinzheng; Ma, Huimin

    2014-10-10

    A chiral ligand exchange capillary electrophoresis (CLE-CE) method using Zn(II) as the central ion and L-4-hydroxyproline as the chiral ligand coordinating with γ-cyclodextrin (γ-CD) was developed for the enantioseparation of amino acids (AAs) and dipeptides. The effects of various separation parameters, including the pH of the running buffer, the ratio of Zn(II) to L-4-hydroxyproline, the concentration of complexes and cyclodextrins (CDs) were systematically investigated. After optimization, it has been found that eight pairs of labeled AAs and six pairs of labeled dipeptides could be baseline-separated with a running electrolyte of 100.0mM boric acid, 5.0mM ammonium acetate, 3.0mM Zn(II), 6.0mM L-hydroxyproline and 4.0mM γ-CD at pH 8.2. The quantitation of AAs and dipeptides was conducted and good linearity (r(2)≥0.997) and favorable repeatability (RSD≤3.6%) were obtained. Furthermore, the proposed method was applied in determining the enantiomeric purity of AAs and dipeptides. Meanwhile, the possible enantiorecognition mechanism based on the synergistic effect of chiral metal complexes and γ-CD was explored and discussed briefly. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. High speed capillary zone electrophoresis-mass spectrometry via an electrokinetically pumped sheath flow interface for rapid analysis of amino acids and a protein digest.

    Science.gov (United States)

    Schiavone, Nicole M; Sarver, Scott A; Sun, Liangliang; Wojcik, Roza; Dovichi, Norman J

    2015-06-01

    While capillary zone electrophoresis (CZE) has been used to produce very rapid and efficient separations, coupling these high-speed separations with mass spectrometry (MS) has been challenging. Now, with much faster and sensitive mass spectrometers, it is possible to take full advantage of the CZE speed and reconstruct the fast migrating peaks. Here are three high-speed CZE-MS analyses via an electrokinetically pumped sheath-flow interface. The first separation demonstrates CZE-ESI-MS of an amino acid mixture with a 2-min separation, >50,000 theoretical plates, low micromolar concentration detection limits, and subfemtomole mass detection limits (LTQ XL mass spectrometer). The second separation with our recently improved third-generation CE-MS interface illustrates a 20 amino acid separation in ∼7min with an average over 200,000 plate counts, and results in almost-baseline resolution of structural isomers, leucine and isoleucine. The third separation is of a BSA digest with a reproducible CZE separation and mass spectrometry detection in 2min. CZE-MS/MS analysis of the BSA digest identified 31 peptides, produced 52% sequence coverage, and generated a peak capacity of ∼40 across the 1-min separation window (Q-Exactive mass spectrometer). Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Radiobiological study on DNA strand breaks and repair using single cell gel electrophoresis

    International Nuclear Information System (INIS)

    Ikushima, Takaji

    1994-01-01

    Single cell gel electrophoresis (SCGE) provides a novel method to measure DNA damage in individual cells and more importantly, to assess heterogeneity in response within a mixed population of cells. Cells embedded in agarose are lysed, subjected to electrophoresis, stained with a fluorescent DNA-specific dye, and viewed under a fluorescence microscope. Damaged cells display 'comets', broken DNA migrating farther to the anode in the electric field. We have previously used this technique to quantify DNA damage induced by moderate doses of low and high LET radiations in cultured Chinese hamster cells. The assay has been optimized in terms of lysing and electrophoresis conditions, and applied to analyse the DNA strand breaks, their repair kinetics and heterogeneity in response in individual Chinese hamster cells exposed to gamma-rays, and to KUR thermal neutrons with and without 10 B or to KEK PF monochromatic soft X-rays as well as to a radio-mimetic agent, neocarzinostatin. The DNA double-strand breaks induced by boron-neutron captured reactions were repaired at a slower rate, but a heterogeneity in response might not contribute to the difference. The neocarzinostatin-induced DNA damage were efficiently repaired in a dose-dependent fashion. The initial amount of gamma-ray induced DNA double-strand breaks was not significantly altered in cells pre-exposed to very low adapting dose. (author)

  8. Recent progress of sample stacking in capillary electrophoresis (2014–2016)

    Czech Academy of Sciences Publication Activity Database

    Šlampová, Andrea; Malá, Zdeňka; Gebauer, Petr; Boček, Petr

    2017-01-01

    Roč. 38, č. 1 (2017), s. 20-32 ISSN 0173-0835 R&D Projects: GA ČR(CZ) GA16-09135S Institutional support: RVO:68081715 Keywords : stacking * zone electrophoresis * trace analysis * review Subject RIV: CB - Analytical Chemistry, Separation OBOR OECD: Analytical chemistry Impact factor: 2.744, year: 2016

  9. An air-pressure-free elastomeric valve for integrated nucleic acid analysis by capillary electrophoresis

    International Nuclear Information System (INIS)

    Jung, Wooseok; Barrett, Matthew; Brooks, Carla; Zenhausern, Frederic; Rivera, Andrew; Birdsell, Dawn N; Wagner, David M

    2015-01-01

    We present a new elastomeric valve for integrated nucleic acid analysis by capillary electrophoresis. The valve functions include metering to capture a designated volume of biological sample into a polymerase chain reaction (PCR) chamber, sealing to preserve the sample during PCR cycling, and transfer of the PCR-products and on-chip formamide post-processing for the analysis of DNA fragments by capillary gel electrophoresis. This new valve differs from prior art polydimethylsiloxane (PDMS) valves in that the valve is not actuated externally by air-pressure or vacuum so that it simplifies a DNA analysis system by eliminating the need for an air-pressure or vacuum source, and off-cartridge solenoid valves, control circuit boards and software. Instead, the new valve is actuated by a thermal cycling peltier assembly integrated within the hardware instrument that tightly comes in contact with a microfluidic cartridge for thermal activation during PCR, so that it spontaneously closes the valve without an additional actuator system. The valve has bumps in the designated locations so that it has a self-alignment that does not require precise alignment of a valve actuator. Moreover, the thickness of the new valve is around 600 μm with an additional bump height of 400 μm so that it is easy to handle and very feasible to fabricate by injection molding compared to other PDMS valves whose thicknesses are around 30–100 μm. The new valve provided over 95% of metering performance in filling the fixed volume of the PCR chamber, preserved over 97% of the sample volume during PCR, and showed very comparable capillary electrophoresis peak heights to the benchtop assay tube controls with very consistent transfer volume of the PCR-product and on-chip formamide. The new valve can perform a core function for integrated nucleic acid analysis by capillary electrophoresis. (paper)

  10. Capillary electrophoresis-MALDI interface based on inkjet technology

    Science.gov (United States)

    Vannatta, Michael W.; Whitmore, Colin D.; Dovichi, Norman J.

    2010-01-01

    An ink jet printer valve and nozzle were used to deliver matrix and sample from an electrophoresis capillary onto a MALDI plate. The system was evaluated by separation of a set of standard peptides. That separation generated up to 40,000 theoretical plates in less than three minutes. Detection limits were 500 amol using an ABI TOF-TOF instrument and 2 fmol for an ABI Q-TOF instrument. Over 70% coverage was obtained for the tryptic digest of α-lactalbumin in less than 2.5 minutes. PMID:19960472

  11. Recent advances of capillary electrophoresis in pharmaceutical analysis.

    Science.gov (United States)

    Suntornsuk, Leena

    2010-09-01

    This review covers recent advances of capillary electrophoresis (CE) in pharmaceutical analysis. The principle, instrumentation, and conventional modes of CE are briefly discussed. Advances in the different CE techniques (non-aqueous CE, microemulsion electrokinetic chromatography, capillary isotachophoresis, capillary electrochromatography, and immunoaffinity CE), detection techniques (mass spectrometry, light-emitting diode, fluorescence, chemiluminescence, and contactless conductivity), on-line sample pretreatment (flow injection) and chiral separation are described. Applications of CE to assay of active pharmaceutical ingredients (APIs), drug impurity testing, chiral drug separation, and determination of APIs in biological fluids published from 2008 to 2009 are tabulated.

  12. Evaluation of iron and selenium losses in metalloproteins separated by gel electrophoresis by ICPMS

    International Nuclear Information System (INIS)

    Gherghel, I.; Fernandez, M.L.; Fernandez, B.; Pereiro, R.; Sanz-Medel, A.

    2009-01-01

    Full text: Metallomics addresses the study of metabolism, transport, and metal-protein interactions aiming to obtain relevant information of physiological and pathological alterations in living organisms. Gel electrophoresis is widely employed in proteomics and its use is actually extending to metallomics. Unfortunately, analysis of proteins by molecular techniques does not offer quantitative information. So, a good alternative could be their determination via the quantification of (semi)metal bound to the protein by ICPMS. In this work, we will show a detailed study of possible losses of protein and/or metal in Fe-bound and selenium proteins (transferrin and glutathione peroxidase, respectively) to evaluate the behaviour of the protein-metal interactions during the electrophoresis process. (author)

  13. Capillary Electrophoresis Method Development : Web-based self-paced training-on-demand

    NARCIS (Netherlands)

    Sänger - van de Griend, Cari

    2015-01-01

    If you use capillary electrophoresis (CE) in your work and want a better understanding of the technique, or want to start with CE method development and want to be well prepared, this course is for you. The course is designed for analytical scientists and technicians who use CE in their regular job,

  14. Determination of molecular weight of silk fibroin by non-gel sieving capillary electrophoresis.

    Science.gov (United States)

    Wei, Wei; Zhang, Yaopeng; Shao, Huili; Hu, Xuechao

    2010-01-01

    A simple non-gel sieving capillary electrophoresis (NGSCE) method was established to determine the MW of silk fibroin using CE. The background electrolyte with a pH of 8.8 was based on three components: polyethylene glycol, tris(hydroxymethyl)aminomethane, and sodium dodecyl sulfate (SDS). NGSCE showed a good linear relationship with satisfactory reproducibility between the migration time and the MW of standard proteins. It was found that the regenerated silk fibroin had an MW around 83 kDa with a wide MW distribution (MWD). This absolute value is lower than the result obtained from SDS-polyacrylamide gel electrophoresis due to the different principles of the methods, but their similar MWD shapes indicated that NGSCE could be a feasible, highly sensitive, rapid method for determination of the MW of silk fibroin.

  15. SHIFT IN HUMAN ROTAVIRUS DISTRIBUTION IN BELO HORIZONTE, BRAZIL DETECTED BY RIBONUCLEIC ACID ELECTROPHORESIS

    Directory of Open Access Journals (Sweden)

    Millan Scarabeli Alves Coelho da Silva

    2013-04-01

    Full Text Available Rotavirus has been considered the main agent of infectious diarrhea especially among younger children. We addressed the prevalence of rotavirus-associated diarrhea and the diversity of circulating electropherotypes by immunochromatography and RNA electrophoresis. Stool samples were taken from 391 children (267 with diarrhea from the lower socioeconomic stratum who sought treatment in the Hospital Infantil João Paulo II/Belo Horizonte, during 2005 and 2006. Rotavirus was detected in 79/20.2% of subjects, 64/24.0% with diarrhea and 15/12.1% with no diarrhea. The virus was strongly associated with diarrhea (p = 0.003. A total of 76/19.4% and 69/17.6% rotavirus-positive children were identified by immunochromatography and electrophoresis, respectively. Rotavirus-associated diarrhea was more frequently detected in dry months (p < 0.001 and almost exclusively in children aged up to three years. Long profile strains prevailed (54/78.3% but a shift toward short electropherotype was identified. Despite the decrease seen in 2006, rotavirus infection is still very common in our area. Although viral RNA electrophoresis is useful as a typing method, it should not be used exclusively in the diagnosis of rotavirus infection. We confirmed a shift from long to short profile strains, as already described for other South American countries.

  16. Capillary electrophoresis tandem mass spectrometry determination of glutamic acid and homocysteine's metabolites: Potential biomarkers of amyotrophic lateral sclerosis.

    Science.gov (United States)

    Cieslarova, Zuzana; Lopes, Fernando Silva; do Lago, Claudimir Lucio; França, Marcondes Cavalcante; Colnaghi Simionato, Ana Valéria

    2017-08-01

    Amyotrophic lateral sclerosis (ALS) is a neurodegenerative disease that affects both lower and upper motor neurons, leading to muscle atrophy, paralysis, and death caused by respiratory failure or infectious complications. Altered levels of homocysteine, cysteine, methionine, and glutamic acid have been observed in plasma of ALS patients. In this context, a method for determination of these potential biomarkers in plasma by capillary electrophoresis tandem mass spectrometry (CE-MS/MS) is proposed herein. Sample preparation was carefully investigated, since sulfur-containing amino acids may interact with plasma proteins. Owing to the non-thiol sulfur atom in methionine, it was necessary to split sample preparation into two methods: i) determination of homocysteine and cysteine as S-acetyl amino acids; ii) determination of glutamic acid and methionine. All amino acids were separated within 25min by CE-MS/MS using 5molL -1 acetic acid as background electrolyte and 5mmolL -1 acetic acid in 50% methanol/H 2 O (v/v) as sheath liquid. The proposed CE-MS/MS method was validated, presenting RSD values below 6% and 11% for intra- and inter-day precision, respectively, for the middle concentration level within the linear range. The limits of detection ranged from 35 (homocysteine) to 268nmolL -1 (glutamic acid). The validated method was applied to the analysis of plasma samples from a group of healthy individuals and patients with ALS, showing the potential of glutamic acid and homocysteine metabolites as biomarkers of ALS. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. On-Chip Electrophoresis in Supported Lipid Bilayer Membranes Achieved Using Low Potentials

    NARCIS (Netherlands)

    van Weerd, Jasper; Krabbenborg, Sven; Eijkel, Jan C.T.; Karperien, Hermanus Bernardus Johannes; Huskens, Jurriaan; Jonkheijm, Pascal

    2014-01-01

    A micro supported lipid bilayer (SLB) electrophoresis method was developed, which functions at low potentials and appreciable operating times. To this end, (hydroxymethyl)-ferrocene (FcCH2OH) was employed to provide an electrochemical reaction at the anode and cathode at low applied potential to

  18. New Approach for Segmentation and Quantification of Two-Dimensional Gel Electrophoresis Images

    DEFF Research Database (Denmark)

    Anjo, Antonio dos; Laurell Blom Møller, Anders; Ersbøll, Bjarne Kjær

    2011-01-01

    Motivation: Detection of protein spots in two-dimensional gel electrophoresis images (2-DE) is a very complex task and current approaches addressing this problem still suffer from significant shortcomings. When quantifying a spot, most of the current software applications include a lot of backgro...

  19. Automated DNA electrophoresis, hybridization and detection

    International Nuclear Information System (INIS)

    Zapolski, E.J.; Gersten, D.M.; Golab, T.J.; Ledley, R.S.

    1986-01-01

    A fully automated, computer controlled system for nucleic acid hybridization analysis has been devised and constructed. In practice, DNA is digested with restriction endonuclease enzyme(s) and loaded into the system by pipette; 32 P-labelled nucleic acid probe(s) is loaded into the nine hybridization chambers. Instructions for all the steps in the automated process are specified by answering questions that appear on the computer screen at the start of the experiment. Subsequent steps are performed automatically. The system performs horizontal electrophoresis in agarose gel, fixed the fragments to a solid phase matrix, denatures, neutralizes, prehybridizes, hybridizes, washes, dries and detects the radioactivity according to the specifications given by the operator. The results, printed out at the end, give the positions on the matrix to which radioactivity remains hybridized following stringent washing

  20. Colloid molecular weight estimation by gel chromatography/acrylamide gel electrophoresis

    International Nuclear Information System (INIS)

    Liberatore, F.A.; Dearborn, C.; Nigam, S.; Poon, C.; Camin, L.; Liteplo, M.

    1984-01-01

    Size or molecular weight (MW) estimation of radiolabeled collides in aqueous solutions has long been a problem. The authors have prepared several minimicroaggregated albumin colloids (mμAA) by heat denaturation of stannous-containing HSA solutions at pH 7.0, 7.5, and 8.5). The resulting colloids were labeled with Tc-99m and compared with Au-198 colloid and Tc-99m-antimony sulfide colloid (Tc-99m-Sb/sub 2/S3) by gel chromatography and gel electrophoresis. Tc-99mm-mμAA aggregated at pH 7.0 and the Au-198 colloid appeared in the external void volume of a BioRad A5.0 agarose column indicating an apparent MW of > 5 x 10/sup 6/ daltons. The pH7.5 Tc-99m-mμAA, migrated within the filtration range of the column as did a small fraction of Tc-99m-Sb/sub 2/S/sub 3/, suggesting that the MW is between 6 x 10/sup 4/ - 5 x 10/sup 6/ daltons. The Tc-99m-mμAA, aggregated at pH 8.5, had an apparent MW on gel filtration similar to that of untreated albumin, MW 6.6 x 10-/sup 4/ daltons. The mobilities of the colloids, on acrylamide disc gel electrophoresis, were consistent with the results on gel chromatography. The largest colloids, Au-198 colloid and pH 7.0 Tc-99m-mμAA, barely entered the separating gel; intermediate sized colloids, a small fraction of Tc-99m-Sb/sub 2/S/sub 3/ and pH 7.5 Tc-99m-mμAA migrated farther into the separating gel; while pH 8.5 Tc-99m-mμAA had mobility approaching that of untreated albumin. Lymphoscintigraphy studies using these colloids in animals showed the predicted, particle size-related differences in migration and clearance. The authors conclude that gel chromatography and gel electrophoresis are useful methods for estimating the apparent size of the colloidal particles

  1. Capillary electrophoresis in a fused-silica capillary with surface roughness gradient

    Czech Academy of Sciences Publication Activity Database

    Horká, Marie; Šlais, Karel; Karásek, Pavel; Růžička, F.; Šalplachta, Jiří; Šesták, Jozef; Kahle, Vladislav; Roth, Michal

    2016-01-01

    Roč. 39, č. 19 (2016), s. 3827-3834 ISSN 1615-9306 R&D Projects: GA ČR(CZ) GA16-03749S; GA MZd(CZ) NV16-29916A Institutional support: RVO:68081715 Keywords : capillary electrophoresis * supercritical water * surface roughness gradient Subject RIV: CB - Analytical Chemistry , Separation Impact factor: 2.557, year: 2016

  2. Capillary electrophoresis in a fused-silica capillary with surface roughness gradient

    Czech Academy of Sciences Publication Activity Database

    Horká, Marie; Šlais, Karel; Karásek, Pavel; Růžička, F.; Šalplachta, Jiří; Šesták, Jozef; Kahle, Vladislav; Roth, Michal

    2016-01-01

    Roč. 39, č. 19 (2016), s. 3827-3834 ISSN 1615-9306 R&D Projects: GA ČR(CZ) GA16-03749S; GA MZd(CZ) NV16-29916A Institutional support: RVO:68081715 Keywords : capillary electrophoresis * supercritical water * surface roughness gradient Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 2.557, year: 2016

  3. Investigation of two different anoxia models by 2-dimensional gel electrophoresis

    DEFF Research Database (Denmark)

    Wulff, Tune; Jessen, Flemming; Hoffmann, Else Kay

    2006-01-01

    anoxia obtained by NaN3 is a widely used model for simulating anoxia (Ossum et al., 2004). The effects of anoxia were studied by protein expression analysis using 2-dimensional gel electrophoresis followed by MS/MS. In this way we were able to separate more than 1500 protein spots with an apparent range...

  4. Evaluation of genotoxicity of the acute gamma radiation on earthworm Eisenia fetida using single cell gel electrophoresis technique (Comet assay).

    Science.gov (United States)

    Sowmithra, K; Shetty, N J; Jha, S K; Chaubey, R C

    2015-12-01

    Earthworms (Eisenia fetida) most suitable biological indicators of radioactive pollution. Radiation-induced lesions in DNA can be considered to be molecular markers for early effects of ionizing radiation. Gamma radiation produces a wide spectrum of DNA. Some of these lesions, i.e., DNA strand breaks and alkali labile sites can be detected by the single-cell gel electrophoresis (SCGE) or comet assay by measuring the migration of DNA from immobilized nuclear DNA. E. fetida were exposed to different doses of gamma radiation, i.e., 1, 5, 10, 20, 30, 40 and 50Gy, and comet assay was performed for all the doses along with control at 1, 3 and 5h post irradiation to evaluate the genotoxicity of gamma radiation in this organism. The DNA damage was measured as percentage of comet tail DNA. A significant increase in DNA damage was observed in samples exposed to 5Gy and above, and the increase in DNA damage was dose dependent i.e., DNA damage was increased with increased doses of radiation. The highest DNA damage was noticed at 1h post irradiation and gradually decreased with time, i.e., at 3 and 5h post irradiation. The present study reveals that gamma radiation induces DNA damage in E. fetida and the comet assay is a sensitive and rapid method for its detection to detect genotoxicity of gamma radiation. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. PCR/LDR/capillary electrophoresis for detection of single-nucleotide differences between fetal and maternal DNA in maternal plasma.

    Science.gov (United States)

    Yi, Ping; Chen, Zhuqin; Zhao, Yan; Guo, Jianxin; Fu, Huabin; Zhou, Yuanguo; Yu, Lili; Li, Li

    2009-03-01

    The discovery of fetal DNA in maternal plasma has opened up an approach for noninvasive diagnosis. We have now assessed the possibility of detecting single-nucleotide differences between fetal and maternal DNA in maternal plasma by polymerase chain reaction (PCR)/ligase detection reaction((LDR)/capillary electrophoresis. PCR/LDR/capillary electrophoresis was applied to detect the genotype of c.454-397T>gene (ESR1) from experimental DNA models of maternal plasma at different sensitivity levels and 13 maternal plasma samples.alphaC in estrogen receptor. (1) Our results demonstrated that the technique could discriminate low abundance single-nucleotide mutation with a mutant/normal allele ratio up to 1:10 000. (2) Examination of ESR1 c.454-397T>C genotypes by using the method of restriction fragment length analysis was performed in 25 pregnant women, of whom 13 pregnant women had homozygous genotypes. The c.454-397T>C genotypes of paternally inherited fetal DNA in maternal plasma of these 13 women were detected by PCR/LDR/capillary electrophoresis, which were accordant with the results of umbilical cord blood. PCR/LDR/capillary electrophoresis has very high sensitivity to distinguish low abundance single nucleotide differences and can discriminate point mutations and single-nucleotide polymorphisms(SNPs) of paternally inherited fetal DNA in maternal plasma.

  6. Dispersive solid-phase microextraction and capillary electrophoresis separation of food colorants in beverages using diamino moiety functionalized silica nanoparticles as both extractant and pseudostationary phase.

    Science.gov (United States)

    Liu, Feng-Jie; Liu, Chuan-Ting; Li, Wei; Tang, An-Na

    2015-01-01

    In this work, a new method for the determination of food colorants in beverage samples is developed, using diamino moiety functionalized silica nanoparticles (dASNPs) as both adsorbents in dispersive solid-phase microextraction (dSPME) and pseudostationary phases (PSPs) in capillary electrophoresis (CE) separation. dASNPs were firstly used as adsorbents for the preconcentration of four colorants by the dSPME process. After that, colorants were efficiently separated by CE using 30 mM phosphate buffer (pH 6.0) containing 2 mM β-CD and 0.9 mg/mL dASNPs as additives. All factors influencing dSPME and CE separations were optimized in detail. The investigated analytes showed good linearities with correlation coefficients (R(2)) higher than 0.9932. The limits of detection for the four food colorants were between 0.030 and 0.36 mg/L, which are lower than those reported previously. The established method was also used to analyze four colorants in beverage samples with recoveries ranging from 82.7% to 114.6%. To the best of our knowledge, this is the first time to use NPs both as extractants in dSPME and pseudostationary phases in CE for the analytical purpose. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Coupling Sodium Dodecyl Sulfate–Capillary Polyacrylamide Gel Electrophoresis with MALDI-TOF-MS via a PTFE Membrane

    Science.gov (United States)

    Lu, Joann J.; Zhu, Zaifang; Wang, Wei; Liu, Shaorong

    2011-01-01

    Sodium dodecyl sulfate (SDS)–polyacrylamide gel electrophoresis (PAGE) is a fundamental analytical technique for proteomic research, and SDS–capillary gel electrophoresis (CGE) is its miniaturized version. Compared to conventional slab-gel electrophoresis, SDS-CGE has many advantages such as increased separation efficiency, reduced separation time and automated operation. SDS-CGE is not widely accepted in proteomic research primarily due to the difficulties in identifying the well-resolved proteins. MALDI–TOF–MS is an outstanding platform for protein identifications. Coupling the two would solve the problem but is extremely challenging because the MS detector has no access to the SDS-CGE resolved proteins and the SDS interferes with MS detection. In this work we introduce an approach to address these issues. We discover that poly(tetrafluoroethylene) (PTFE) membranes are excellent materials for collecting SDS-CGE separated proteins. We demonstrate that we can wash off the SDS bound to the collected proteins and identify these proteins on-membrane with MALDI-TOF-MS. We also show that we can immunoblot and Coomassie-stain the proteins collected on these membranes. PMID:21309548

  8. Startup of electrophoresis in a suspension of colloidal spheres.

    Science.gov (United States)

    Chiang, Chia C; Keh, Huan J

    2015-12-01

    The transient electrophoretic response of a homogeneous suspension of spherical particles to the step application of an electric field is analyzed. The electric double layer encompassing each particle is assumed to be thin but finite, and the effect of dynamic electroosmosis within it is incorporated. The momentum equation for the fluid outside the double layers is solved through the use of a unit cell model. Closed-form formulas for the time-evolving electrophoretic and settling velocities of the particles in the Laplace transform are obtained in terms of the electrokinetic radius, relative mass density, and volume fraction of the particles. The time scale for the development of electrophoresis and sedimentation is significantly smaller for a suspension with a higher particle volume fraction or a smaller particle-to-fluid density ratio, and the electrophoretic mobility at any instant increases with an increase in the electrokinetic particle radius. The transient electrophoretic mobility is a decreasing function of the particle volume fraction if the particle-to-fluid density ratio is relatively small, but it may increase with an increase in the particle volume fraction if this density ratio is relatively large. The particle interaction effect in a suspension on the transient electrophoresis is much weaker than that on the transient sedimentation of the particles. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Mapping and identification of interferon gamma-regulated HeLa cell proteins separated by immobilized pH gradient two-dimensional gel electrophoresis

    DEFF Research Database (Denmark)

    Shaw, A.; Larsen, M.; Roepstorff, P.

    1999-01-01

    magnitude of IFN-gamma responsive genes has been reported previously. Our goal is to identify and map IFN-gamma-regulated HeLa cell proteins to the two-dimensional polyacrylamide gel electrophoresis with the immobilized pH gradient (IPG) two-dimensional polyacrylamide gel electrophoresis (2-D PAGE) system...

  10. Capillary electrophoresis in an extended nanospray tip-electrospray as an electrophoretic column

    Czech Academy of Sciences Publication Activity Database

    Týčová, Anna; Foret, František

    2015-01-01

    Roč. 1388, APR (2015), s. 274-279 ISSN 0021-9673 R&D Projects: GA ČR(CZ) GBP206/12/G014 Institutional support: RVO:68081715 Keywords : mass spectrometry * interface * separation * capillary electrophoresis Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.926, year: 2015

  11. Genetic heterogeneity of Campylobacter concisus determined by pulsed field gel electrophoresis-based macrorestriction profiling

    DEFF Research Database (Denmark)

    Matsheka, M.I.; Elisha, B.G.; Lastovica, A.L.

    2002-01-01

    1 for pulsed field gel electrophoresis-based genotyping. Subsequently, 53 strains of C concisus, principally from cases of diarrhoea in children, were examined. Fifty-one distinct patterns were obtained, indicating the high discriminatory potential of the method. Patterns comprised between one...... comprised of several genomospecies. The pulsed field gel electrophoresis typing method described here has considerable potential for molecular epidemiological studies of C concisus and may be a useful adjunctive method for helping to resolve key taxonomic issues for this species....... and 14 restriction fragments, with type and reference strains of two well-defined genomospecies of oral and faecal origin containing six and 12 fragments respectively. Our results show that C concisus is genetically diverse and suggest the species as currently defined to be a taxonomic continuum...

  12. Establishment of reference intervals for plasma protein electrophoresis in Indo-Pacific green sea turtles, Chelonia mydas.

    Science.gov (United States)

    Flint, Mark; Matthews, Beren J; Limpus, Colin J; Mills, Paul C

    2015-01-01

    Biochemical and haematological parameters are increasingly used to diagnose disease in green sea turtles. Specific clinical pathology tools, such as plasma protein electrophoresis analysis, are now being used more frequently to improve our ability to diagnose disease in the live animal. Plasma protein reference intervals were calculated from 55 clinically healthy green sea turtles using pulsed field electrophoresis to determine pre-albumin, albumin, α-, β- and γ-globulin concentrations. The estimated reference intervals were then compared with data profiles from clinically unhealthy turtles admitted to a local wildlife hospital to assess the validity of the derived intervals and identify the clinically useful plasma protein fractions. Eighty-six per cent {19 of 22 [95% confidence interval (CI) 65-97]} of clinically unhealthy turtles had values outside the derived reference intervals, including the following: total protein [six of 22 turtles or 27% (95% CI 11-50%)], pre-albumin [two of five, 40% (95% CI 5-85%)], albumin [13 of 22, 59% (95% CI 36-79%)], total albumin [13 of 22, 59% (95% CI 36-79%)], α- [10 of 22, 45% (95% CI 24-68%)], β- [two of 10, 20% (95% CI 3-56%)], γ- [one of 10, 10% (95% CI 0.3-45%)] and β-γ-globulin [one of 12, 8% (95% CI 0.2-38%)] and total globulin [five of 22, 23% (8-45%)]. Plasma protein electrophoresis shows promise as an accurate adjunct tool to identify a disease state in marine turtles. This study presents the first reference interval for plasma protein electrophoresis in the Indo-Pacific green sea turtle.

  13. Capillaries for use in a multiplexed capillary electrophoresis system

    Science.gov (United States)

    Yeung, E.S.; Chang, H.T.; Fung, E.N.

    1997-12-09

    The invention provides a side-entry optical excitation geometry for use in a multiplexed capillary electrophoresis system. A charge-injection device is optically coupled to capillaries in the array such that the interior of a capillary is imaged onto only one pixel. In Sanger-type 4-label DNA sequencing reactions, nucleotide identification (``base calling``) is improved by using two long-pass filters to split fluorescence emission into two emission channels. A binary poly(ethyleneoxide) matrix is used in the electrophoretic separations. 19 figs.

  14. Electronic imaging systems for quantitative electrophoresis of DNA

    International Nuclear Information System (INIS)

    Sutherland, J.C.

    1989-01-01

    Gel electrophoresis is one of the most powerful and widely used methods for the separation of DNA. During the last decade, instruments have been developed that accurately quantitate in digital form the distribution of materials in a gel or on a blot prepared from a gel. In this paper, I review the various physical properties that can be used to quantitate the distribution of DNA on gels or blots and the instrumentation that has been developed to perform these tasks. The emphasis here is on DNA, but much of what is said also applies to RNA, proteins and other molecules. 36 refs

  15. Progress in two-dimensional polyacrylamide gel electrophoresis and application in radiation research

    International Nuclear Information System (INIS)

    Wang Zhidong; Chen Xiaohua

    2003-01-01

    Two-dimensional polyacrylamide gel electrophoresis is the key separation technique in proteomics research, which is designed by protein character: molecular weight and PI. Some progress has been made in disease mechanism detection, tumor indicator research and drug development. This technique also has some potential application in radiation research

  16. Simple approach for the fabrication of screen-printed carbon-based electrode for amperometric detection on microchip electrophoresis.

    Science.gov (United States)

    Petroni, Jacqueline Marques; Lucca, Bruno Gabriel; Ferreira, Valdir Souza

    2017-02-15

    This paper describes a simple method for the fabrication of screen-printed based electrodes for amperometric detection on microchip electrophoresis (ME) devices. The procedure developed is quite simple and does not require expensive instrumentation or sophisticated protocols commonly employed on the production of amperometric sensors, such as photolithography or sputtering steps. The electrodes were fabricated through manual deposition of home-made conductive carbon ink over patterned acrylic substrate. Morphological structure and electrochemical behavior of the carbon electrodes were investigated by scanning electron microscopy and cyclic voltammetry. The produced amperometric sensors were coupled to polydimethylsiloxane (PDMS) microchips at end-channel configuration in order to evaluate their analytical performance. For this purpose, electrophoretic experiments were carried out using nitrite and ascorbic acid as model analytes. Separation of these substances was successfully performed within 50s with good resolution (R = 1.2) and sensitivities (713.5 pA/μM for nitrite and 255.4 pA/μM for ascorbate). The reproducibility of the fabrication method was evaluated and revealed good values concerning the peak currents obtained (8.7% for nitrite and 9.3% for ascorbate). The electrodes obtained through this method exhibited satisfactory lifetime (ca. 400 runs) over low fabrication cost (less than $1 per piece). The feasibility of the proposed device for real analysis was demonstrated through the determination of nitrite concentration levels in drinking water samples. Based on the results achieved, the approach proposed here shows itself as an interesting alternative for simple fabrication of carbon-based electrodes. Furthermore, the devices indicate great promise for other kind of analytical applications involving ME devices. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Sexual rights as human rights: a guide to authoritative sources and principles for applying human rights to sexuality and sexual health.

    Science.gov (United States)

    Miller, Alice M; Kismödi, Eszter; Cottingham, Jane; Gruskin, Sofia

    2015-11-01

    This Guide seeks to provide insight and resources to actors interested in the development of rights claims around sexuality and sexual health. After engaging with the vexed question of the scope of sexual rights, it explores the rules and principles governing the way in which human rights claims are developed and applied to sexuality and sexual health, and how that development is linked to law and made a matter of state obligation. This understanding is critical to policy and programming in sexual health and rights, as it supports calling on the relevant range of human rights, such as privacy, non-discrimination, health or other universally accepted human rights, as well as demanding the action of states under their international and national law obligations to support sexual health. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Biosphere reserves: Attributes for success.

    Science.gov (United States)

    Van Cuong, Chu; Dart, Peter; Hockings, Marc

    2017-03-01

    Biosphere reserves established under the UNESCO Man and the Biosphere Program aim to harmonise biodiversity conservation and sustainable development. Concerns over the extent to which the reserve network was living up to this ideal led to the development of a new strategy in 1995 (the Seville Strategy) to enhance the operation of the network of reserves. An evaluation of effectiveness of management of the biosphere reserve network was called for as part of this strategy. Expert opinion was assembled through a Delphi Process to identify successful and less successful reserves and investigate common factors influencing success or failure. Ninety biosphere reserves including sixty successful and thirty less successful reserves in 42 countries across all five Man and the Biosphere Program regions were identified. Most successful sites are the post-Seville generation while the majority of unsuccessful sites are pre-Seville that are managed as national parks and have not been amended to conform to the characteristics that are meant to define a biosphere reserve. Stakeholder participation and collaboration, governance, finance and resources, management, and awareness and communication are the most influential factors in the success or failure of the biosphere reserves. For success, the biosphere reserve concept needs to be clearly understood and applied through landscape zoning. Designated reserves then need a management system with inclusive good governance, strong participation and collaboration, adequate finance and human resource allocation and stable and responsible management and implementation. All rather obvious but it is difficult to achieve without commitment to the biosphere reserve concept by the governance authorities. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Determination of Cyclam as Impurity in 99mTc-CTMP Using Radio electrophoresis Method

    International Nuclear Information System (INIS)

    Isti Daruwati; Misyetti; Maula Eka Sriyani; Teguh Hafiz AW

    2009-01-01

    Labelled compound of CTMP that are used for bone seeking radiopharmaceuticals must have to fulfill the standard requirements, such as have high radiochemical purity. CTMP compounds was in house synthesized from cyclam and formaldehyde in an acidic condition (conc. HCl) using Mannich methods. Impurities in CTMP product are the residue of cyclam, phosphoric acid, formaldehyde and hydrochloric acid. Formaldehyde and hydrochloride acid in the aqueous form is easily removed through the rinse process in the synthesis, while cyclam in the solid phase could be mix with CTMP. Therefore the impurities of cyclam in 99m Tc-CTMP must be determined. With nuclear technique, the determination of cyclam could be assessed simultaneously with labelled of CTMP with technetium-99m. Separation of 99m Tc-CTMP and 99m Tc-cyclam in solution was conducted with radio-electrophoresis method simultaneously. The radiochemical purity for both radiolabelled compound was determined by paper chromatography. The purity of radiolabelled 99m Tc-CTMP from cyclam was determined using electrophoresis method. The result show that the amount of cyclam in CTMP can be determined simultaneously using nuclear techniques with the labeling of 99m Tc-CTMP. Electrophoresis method can separated 99m Tc-cyclam, 99m Tc-CTMP, 99m TcO4 and 99m Tc-reduced with limit quantitation of cyclam until 0,4% w/w. (author)

  20. An XML standard for the dissemination of annotated 2D gel electrophoresis data complemented with mass spectrometry results

    Directory of Open Access Journals (Sweden)

    Arthur John

    2004-01-01

    Full Text Available Abstract Background Many proteomics initiatives require a seamless bioinformatics integration of a range of analytical steps between sample collection and systems modeling immediately assessable to the participants involved in the process. Proteomics profiling by 2D gel electrophoresis to the putative identification of differentially expressed proteins by comparison of mass spectrometry results with reference databases, includes many components of sample processing, not just analysis and interpretation, are regularly revisited and updated. In order for such updates and dissemination of data, a suitable data structure is needed. However, there are no such data structures currently available for the storing of data for multiple gels generated through a single proteomic experiments in a single XML file. This paper proposes a data structure based on XML standards to fill the void that exists between data generated by proteomics experiments and storing of data. Results In order to address the resulting procedural fluidity we have adopted and implemented a data model centered on the concept of annotated gel (AG as the format for delivery and management of 2D Gel electrophoresis results. An eXtensible Markup Language (XML schema is proposed to manage, analyze and disseminate annotated 2D Gel electrophoresis results. The structure of AG objects is formally represented using XML, resulting in the definition of the AGML syntax presented here. Conclusion The proposed schema accommodates data on the electrophoresis results as well as the mass-spectrometry analysis of selected gel spots. A web-based software library is being developed to handle data storage, analysis and graphic representation. Computational tools described will be made available at http://bioinformatics.musc.edu/agml. Our development of AGML provides a simple data structure for storing 2D gel electrophoresis data.

  1. An XML standard for the dissemination of annotated 2D gel electrophoresis data complemented with mass spectrometry results.

    Science.gov (United States)

    Stanislaus, Romesh; Jiang, Liu Hong; Swartz, Martha; Arthur, John; Almeida, Jonas S

    2004-01-29

    Many proteomics initiatives require a seamless bioinformatics integration of a range of analytical steps between sample collection and systems modeling immediately assessable to the participants involved in the process. Proteomics profiling by 2D gel electrophoresis to the putative identification of differentially expressed proteins by comparison of mass spectrometry results with reference databases, includes many components of sample processing, not just analysis and interpretation, are regularly revisited and updated. In order for such updates and dissemination of data, a suitable data structure is needed. However, there are no such data structures currently available for the storing of data for multiple gels generated through a single proteomic experiments in a single XML file. This paper proposes a data structure based on XML standards to fill the void that exists between data generated by proteomics experiments and storing of data. In order to address the resulting procedural fluidity we have adopted and implemented a data model centered on the concept of annotated gel (AG) as the format for delivery and management of 2D Gel electrophoresis results. An eXtensible Markup Language (XML) schema is proposed to manage, analyze and disseminate annotated 2D Gel electrophoresis results. The structure of AG objects is formally represented using XML, resulting in the definition of the AGML syntax presented here. The proposed schema accommodates data on the electrophoresis results as well as the mass-spectrometry analysis of selected gel spots. A web-based software library is being developed to handle data storage, analysis and graphic representation. Computational tools described will be made available at http://bioinformatics.musc.edu/agml. Our development of AGML provides a simple data structure for storing 2D gel electrophoresis data.

  2. Success and failure with phthalate buffers in capillary zone electrophoresis.

    Science.gov (United States)

    Bocek, P; Gebauer, P; Beckers, J L

    2001-04-01

    Phthalate buffers are currently used in capillary electrophoresis as robust electrolyte systems for indirect detection. This contribution demonstrates that these buffers show regularly not only successful regions of mobilities of analytes (sample window) but also regions of failure where the migration of analytes is strongly deteriorated due to the presence of a system zone. System zones in phthalate buffers may be easily detected by UV detection and manifest themselves as peaks or dips. Peak shape diagrams are advantageously used for the prediction of the migration behavior of system zones in phthalate background electrolyte (BGE) systems at various pH. It is shown that the mobility of the system zone varies strongly with pH, is practically zero at pH values below 4 and above 7, and shows a maximum at pH 5. Thus, the system peak may coincide either with the peaks of various analytes or with the electroosmotic flow (EOF) peak. Experiments are given showing the effects of such coincidences as, e.g., zigzag detection patterns, double EOF peaks, and/or unusually broad peaks/dips. The message of this contribution is to show how to understand the electrophoretic properties of phthalate BGEs that, regardless of possible failure regions, may be successfully used in the analytical practice of capillary zone electrophoresis (CZE).

  3. Lesion measurement in non-radioactive DNA by quantitative gel electrophoresis

    International Nuclear Information System (INIS)

    Sutherland, J.C.; Chen, Chun Zhang; Emrick, A.; Hacham, H; Monteleone, D.; Ribeiro, E.; Trunk, J.; Sutherland, B.M.

    1989-01-01

    The gel electrophoresis method developed during the past ten years in our laboratories makes possible the quantitation of UV induced pyrimidine dimers, gamma ray induced single- and double-strand breaks and many other types of lesions in nanogram quantities of DNA. The DNA does not have to be labeled with radionuclides or of a particular conformation, thus facilitating the use of the method in measuring damage levels and repair rates in the DNA of intact organisms -- including man. The gel method can quantitate any lesion in DNA that either is, or can be converted to a single- or double-strand break. The formation of a strand break produces two shorter DNA molecules for each molecule that existed before the treatment that produced the break. Determining the number of breaks, and hence the number of lesions, becomes a matter of comparing the average lengths of molecules in samples differing only in lesion-induced breaks. This requires that we determine the distribution of mass of DNA on a gel as a function of its distance of migration and also the dispersion function of its distance of migration and also the dispersion function (the relationship between molecular length and distance of migration) in the gel electrophoresis system. 40 refs., 5 figs

  4. EXAFS analysis of a human Cu,Zn SOD isoform focused using non-denaturing gel electrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Chevreux, Sylviane; Roudeau, Stephane; Deves, Guillaume; Ortega, Richard [Laboratoire de Chimie Nucleaire Analytique et Bioenvironnementale, CNRS UMR5084, Universite Bordeaux 1, Chemin du Solarium, F-33175 Gradignan cedex (France); Solari, Pier Lorenzo [Synchrotron SOLEIL, L' Orme des Merisiers, BP 48, F-91192 Gif-sur-Yvette cedex, Saint-Aubin (France); Alliot, Isabelle; Testemale, Denis; Hazemann, Jean Louis, E-mail: ortega@cenbg.in2p3.f [FAME, ESRF, 6 rue Jules Horowitz, BP220, F-38043 Grenoble cedex (France)

    2009-11-15

    Isoelectric point isoforms of a metalloprotein, copper-zinc superoxide dismutase (CuZnSOD), separated on electrophoresis gels were analyzed using X-ray Absorption Spectroscopy. Mutations of this protein are involved in familial cases of amyotrophic lateral sclerosis. The toxicity of mutants could be relied to defects in the metallation state. Our purpose is to establish analytical protocols to study metallation state of protein isoforms such as those from CuZnSOD. We previously highlighted differences in the copper oxidation state between CuZnSOD isoforms using XANES. Here, we present the first results for EXAFS analyses performed at Cu and Zn K-edge on the majoritary expressed isoform of human CuZnSOD separated on electrophoresis gels.

  5. EXAFS analysis of a human Cu,Zn SOD isoform focused using non-denaturing gel electrophoresis

    Science.gov (United States)

    Chevreux, Sylviane; Solari, Pier Lorenzo; Roudeau, Stéphane; Deves, Guillaume; Alliot, Isabelle; Testemale, Denis; Hazemann, Jean Louis; Ortega, Richard

    2009-11-01

    Isoelectric point isoforms of a metalloprotein, copper-zinc superoxide dismutase (CuZnSOD), separated on electrophoresis gels were analyzed using X-ray Absorption Spectroscopy. Mutations of this protein are involved in familial cases of amyotrophic lateral sclerosis. The toxicity of mutants could be relied to defects in the metallation state. Our purpose is to establish analytical protocols to study metallation state of protein isoforms such as those from CuZnSOD. We previously highlighted differences in the copper oxidation state between CuZnSOD isoforms using XANES. Here, we present the first results for EXAFS analyses performed at Cu and Zn K-edge on the majoritary expressed isoform of human CuZnSOD separated on electrophoresis gels.

  6. EXAFS analysis of a human Cu,Zn SOD isoform focused using non-denaturing gel electrophoresis

    International Nuclear Information System (INIS)

    Chevreux, Sylviane; Roudeau, Stephane; Deves, Guillaume; Ortega, Richard; Solari, Pier Lorenzo; Alliot, Isabelle; Testemale, Denis; Hazemann, Jean Louis

    2009-01-01

    Isoelectric point isoforms of a metalloprotein, copper-zinc superoxide dismutase (CuZnSOD), separated on electrophoresis gels were analyzed using X-ray Absorption Spectroscopy. Mutations of this protein are involved in familial cases of amyotrophic lateral sclerosis. The toxicity of mutants could be relied to defects in the metallation state. Our purpose is to establish analytical protocols to study metallation state of protein isoforms such as those from CuZnSOD. We previously highlighted differences in the copper oxidation state between CuZnSOD isoforms using XANES. Here, we present the first results for EXAFS analyses performed at Cu and Zn K-edge on the majoritary expressed isoform of human CuZnSOD separated on electrophoresis gels.

  7. DESIGN OF ELECTROPHORESIS DEVICE FOR OPTIMATION OF DNA VISUALIZATION AND DNA CONCENTRATION USING SOFTWARE

    Directory of Open Access Journals (Sweden)

    H.P. Kusumaningrum

    2014-07-01

    Full Text Available Molekul DNA menunjukkan polarisasi yang kuat sehingga memungkinkan baik gerak elektroforesis berdasarkan muatan negatifnya maupun gerak dielektroforesis berdasarkan induksi polarisasi. Perancangan alat menggunakan kombinasi prinsip elektroforesis dan dielektroforesis dilengkapi perangkat lunak untuk mengukur konsentrasinya sangat diperlukan. Utamanya mengingat uji kualitatif DNA berbasis visualisasi pada gel elektroforesis bersifat sangat subyektif dan kurang terukur. Pengukuran konsentrasi DNA menggunakan spektrofotometer UV/VIS sangat tergantung oleh ketersediaannya di laboratorium. Penelitian bertujuan untuk mendesain piranti untuk mengukur konsentrasi DNA berdasarkan visualisasinya pada gel elektroforesis menggunakan perangkat lunak berbasis MatLab. Pengukuran konsentrasi DNA didasarkan visualisasinya pada gel elektroforesis lalu dibandingkan dengan hasil penghitungan spektrofotometer UV/VIS. Hasil penelitian menggunakan piranti tersebut memperlihatkan visualisasi DNA yang lebih optimal. Hasil pengukuran jumlah DNA menggunakan spektrofotometer memiliki kecenderungan yang sama dengan hasil pengukuran menggunakan perangkat lunak berbasis MatLab meskipun terdapat perbedaan nilai kuantitatif.ABSTRACTMolecules of deoxyribo nucleic acid (DNA show a strong polarization allowing for both motions of the dielectrophoresis induced by polarization and electrophoresis based on its negative charge. Considering high subjective and less quantifiable result of the visualization based qualitative test of DNA on gel electrophoresis, designing the tool using a combination of the principles of electrophoresis and dielectrophoresis completed with a software for optimization of DNA visualization and to measure the concentration of small and large–sized DNA fragment is very needed. Accuracy of measurement of DNA concentration using a spectrophotometer UV /VIS is depend on its availability in the laboratory. The aim of this study was to design device for

  8. Pulsed-field Gel Electrophoresis for Salmonella Infection Surveillance, Texas, USA, 2007

    Centers for Disease Control (CDC) Podcasts

    2010-06-14

    This podcast describes monitoring of the use of pulsed-field gel electrophoresis for Salmonella surveillance in Houston, Texas. CDC microbiologist Peter Gerner-Smidt discusses the importance of the PulseNet national database in surveillance of food-borne infections.  Created: 6/14/2010 by National Center for Emerging and Zoonotic Infectious Diseases (NCEZID).   Date Released: 6/14/2010.

  9. A chip-type thin-layer electrochemical cell coupled with capillary electrophoresis for online separation of electrode reaction products

    Energy Technology Data Exchange (ETDEWEB)

    He, Jian-Bo, E-mail: jbhe@hfut.edu.cn; Cui, Ting; Zhang, Wen-Wen; Deng, Ning

    2013-07-05

    Graphical abstract: -- Highlights: •A new coupling of thin-layer electrolysis with capillary electrophoresis (CE). •Rapid electrolysis, direct sampling followed by online CE separation. •At least 13 products of quercetin oxidation were separated. •Thermodynamic and kinetic parameters were determined from CE peak areas. -- Abstract: A coupling technique of thin-layer electrolysis with high-performance capillary electrophoresis/UV–vis technique(EC/HPCE/UV–vis) is developed for online separation and determination of electrode reaction products. A chip-type thin-layer electrolytic (CTE) cell was designed and fabricated, which contains a capillary channel and a background electrolyte reservoir, allowing rapid electrolysis, direct sampling and online electrophoretic separation. This chip-type setup was characterized based on an electrophoresis expression of Nernst equation that was applied to the redox equilibrium of o-tolidine at different potentials. The utility of the method was demonstrated by separating and determining the electro-oxidation products of quercetin in different pH media. Two main products were always found in the studied time, potential and pH ranges. The variety of products increased not only with increasing potential but also with increasing pH value, and in total, at least 13 products were observed in the electropherograms. This work illustrates a novel example of capillary electrophoresis used online with thin-layer electrolysis to separate and detect electrode reaction products.

  10. A chip-type thin-layer electrochemical cell coupled with capillary electrophoresis for online separation of electrode reaction products

    International Nuclear Information System (INIS)

    He, Jian-Bo; Cui, Ting; Zhang, Wen-Wen; Deng, Ning

    2013-01-01

    Graphical abstract: -- Highlights: •A new coupling of thin-layer electrolysis with capillary electrophoresis (CE). •Rapid electrolysis, direct sampling followed by online CE separation. •At least 13 products of quercetin oxidation were separated. •Thermodynamic and kinetic parameters were determined from CE peak areas. -- Abstract: A coupling technique of thin-layer electrolysis with high-performance capillary electrophoresis/UV–vis technique(EC/HPCE/UV–vis) is developed for online separation and determination of electrode reaction products. A chip-type thin-layer electrolytic (CTE) cell was designed and fabricated, which contains a capillary channel and a background electrolyte reservoir, allowing rapid electrolysis, direct sampling and online electrophoretic separation. This chip-type setup was characterized based on an electrophoresis expression of Nernst equation that was applied to the redox equilibrium of o-tolidine at different potentials. The utility of the method was demonstrated by separating and determining the electro-oxidation products of quercetin in different pH media. Two main products were always found in the studied time, potential and pH ranges. The variety of products increased not only with increasing potential but also with increasing pH value, and in total, at least 13 products were observed in the electropherograms. This work illustrates a novel example of capillary electrophoresis used online with thin-layer electrolysis to separate and detect electrode reaction products

  11. Study of the interaction of boron-containing amino acids for the neutron capture therapy with biologically interesting compounds by using 'three-spot zone electrophoresis'

    International Nuclear Information System (INIS)

    Kitaoka, Yoshinori; Kobayashi, Mitsue; Morimoto, Tsuguhiro; Kirihata, Mitsunori; Ichimoto, Itsuo.

    1995-01-01

    As the boron carriers for boron neutron capture therapy, p-borono phenylalanine (BPA) is the boron compound which has been clinically used together with sodium borocaptate. It was found by the electrophoresis behavior that the BPA interacted with organic carboxylic acids in its dissolved state. In this paper, the electrophoresis behavior of general amino acids as seen in three-spot zone electrophoresis and the peculiar interaction of the amino acids having dihydroxyboryl radical are described. Zone electrophoresis has been developed as separation means, and three-spot process excludes the errors due to accidental factors as far as possible. The behaviors of zone electrophoresis of ordinary neutral amino acids, orthoboric acid and p-BPA are reported. For utilizing the features of boron neutron capture therapy, it is necessary to develop the carrier which is singularly taken into cancer cells. There is not a good method for discriminating normal cells and cancer cells. As for the administration of BPA to patients, its solubility is insufficient, therefore, its fructose complex has been used. The research on the biochemical peculiarity of boron is important. (K.I.)

  12. Two Dimensional Electrophoresis of Proteins from Cultures of Erysiphe graminis f.sp. hordei

    DEFF Research Database (Denmark)

    Torp, J.; Andersen, Brian

    1982-01-01

    Conidial proteins from barley powdery mildew, Erysiphe graminis f. sp. hordei, were separated by 2-dimensional electrophoresis in polyacrylamide slab gels. Isoelectric focusing was used in the first dimension and separation according to molecular weight in a gel containing sodium dodecyl sulphate...

  13. Children's rights and school psychology: children's right to participation.

    Science.gov (United States)

    Lansdown, Gerison; Jimerson, Shane R; Shahroozi, Reza

    2014-02-01

    The Convention on the Rights of the Child detailed an international imperative to fulfilling, protecting, and respecting the rights of every child. In particular, the Convention set out a clear mandate for guaranteeing opportunities for children to be heard on all matters of concern to them. The attainment of these goals involves respecting and valuing children as active participants in the educational process. If fully implemented, the right of children to express views and have them taken seriously, throughout the school environment, would represent one of the most profound transformations in moving towards a culture of respect for children's rights, for their dignity and citizenship, and for their capacities to contribute significantly towards their own well-being. These values and principles are consistent with those of the school psychology profession, thus, school psychologists are encouraged to be at the Center of the process advocating and actualizing the Convention in schools throughout the world. Copyright © 2014 Society for the Study of School Psychology. Published by Elsevier Ltd. All rights reserved.

  14. Development of a multiplexed interface for capillary electrophoresis-electrospray ion trap mass spectrometry.

    Science.gov (United States)

    Li, Fu-An; Wu, Ming-Chi; Her, Guor-Rong

    2006-08-01

    A four-channel multiplexed electrospray capillary electrophoresis interface has been developed. This new interface permits up to four capillary electrophoresis columns to be sampled sequentially by means of a stepper motor and a notched rotating plate assembly, which at any instant occludes all but a single sprayer. In this design, four sheath liquid electrospray probes are oriented in a circular array situated 90 degrees relative to one another. The rotating metal disk, which contains a one-quarter notch, is mounted to the stepper motor assembly and is located between the sprayers and the entrance aperture of an ion trap mass spectrometer. By using the data acquisition signal from the ion trap mass spectrometer, the scan event is synchronized with the rotation of the metal disk. With this device, four discrete sample streams can be simultaneously analyzed, resulting in a 4-fold increase in analytical throughput.

  15. Detection of human DNA polymorphisms with a simplified denaturing gradient gel electrophoresis technique

    International Nuclear Information System (INIS)

    Noll, W.W.; Collins, M.

    1987-01-01

    Single base pair differences between otherwise identical DNA molecules can result in altered melting behavior detectable by denaturing gradient gel electrophoresis. The authors have developed a simplified procedure for using denaturing gradient gel electrophoresis to detect base pair changes in genomic DNA. Genomic DNA is digested with restriction enzymes and hybridized in solution to labeled single-stranded probe DNA. The excess probe is then hybridized to complementary phage M13 template DNA, and the reaction mixture is electrophoresed on a denaturing gradient gel. Only the genomic DNA probe hybrids migrate into the gel. Differences in hybrid mobility on the gel indicate base pair changes in the genomic DNA. They have used this technique to identify two polymorphic sites within a 1.2-kilobase region of human chromosome 20. This approach should greatly facilitate the identification of DNA polymorphisms useful for gene linkage studies and the diagnosis of genetic diseases

  16. Comparison between pulsed-field and constant-field gel electrophoresis for measurement of DNA double-strand breaks in irradiated Chinese hamster ovary cells

    International Nuclear Information System (INIS)

    Wlodek, D.; Banath, J.; Olive, P.L.

    1991-01-01

    Pulsed-field gel electrophoresis (PFGE) is one of the most sensitive methods for detecting DNA double-strand breaks in mammalian cells. However, it has been observed that constant-field gel electrophoresis (CFGE), when optimized, can detect breaks with equal efficiency. The migration of DNA from the well and the separation of DNA molecules according to size appear to be different processes; only the latter requires the application of PFGE. CFGE is very sensitive and can detect DNA damage produced by less than 5Gy of radiation. Low voltage (ca.0.6V/cm) during electrophoresis appears to be essential for the migration of the largest fraction of DNA from the agarose plug containing the cells; the electrophoresis run time, cell density in the plug, agarose concentration, nature of detergent and extent of radiolabelling are less important. It is concluded that CFGE is equally sensitive but more rapid and economical than PFGE for the measurement of DNA damage. (author)

  17. Analytical applications of the electrochemiluminescence of tris(2,2'-bipyridyl)ruthenium(II) coupled to capillary/microchip electrophoresis: A review

    International Nuclear Information System (INIS)

    Su Ming; Wei Wei; Liu Songqin

    2011-01-01

    Graphical abstract: The mechanism of Ru(bpy) 3 2+ electrochemiluminescence, addition mode of Ru(bpy) 3 2+ , recent applications of capillary electrophoresis coupled with electrochemiluminescent detection in drug and other substrates analysis are reviewed. - Abstract: A comprehensive review on the development of analytical methods, by coupling electrochemiluminescence (ECL) detection with capillary electrophoresis (CE) and microchip electrophoresis (ME), is presented. After the description of the basic mechanism of ECL, the addition mode of luminescence reagent in CE-ECL system has been discussed. The analytical applications of the CE-ECL technique in terms of different analytes are also given. Due to the importance of ME as a separation method for the present and future, the ME detection methods based on ECL are considered in a relatively detailed way. Finally, possible trends for CE/ME-ECL in the near future are discussed.

  18. Photopatterned free-standing polyacrylamide gels for microfluidic protein electrophoresis.

    Science.gov (United States)

    Duncombe, Todd A; Herr, Amy E

    2013-06-07

    Designed for compatibility with slab-gel polyacrylamide gel electrophoresis (PAGE) reagents and instruments, we detail development of free-standing polyacrylamide gel (fsPAG) microstructures supporting electrophoretic performance rivalling that of microfluidic platforms. For the protein electrophoresis study described here, fsPAGE lanes are comprised of a sample reservoir and contiguous separation gel. No enclosed microfluidic channels are employed. The fsPAG devices (120 μm tall) are directly photopatterned atop of and covalently attached to planar polymer or glass surfaces. Leveraging the fast prototype-test cycle - significantly faster than mold based fabrication techniques - we optimize the fsPAG architecture to minimize injection dispersion for rapid (prototyping of the fsPAGE provides researchers a powerful tool for developing custom analytical assays. We highlight the utility of assay customization by fabricating a polyacrylamide gel with a spatial pore-size distribution and demonstrate the resulting enhancement in separation performance over a uniform gel. Further, we up-scale from a unit separation to an array of 96 concurrent fsPAGE assays in 10 min run time driven by one electrode pair. The fsPAG array layout matches that of a 96-well plate to facilitate integration of the planar free standing gel array with multi-channel pipettes while remaining compatible with conventional slab-gel PAGE reagents, such as staining for label-free protein detection. Notably, the entire fsPAGE workflow from fabrication, to operation, and readout uses readily available materials and instruments - making this technique highly accessible.

  19. Recent applications of nanomaterials in capillary electrophoresis.

    Science.gov (United States)

    González-Curbelo, Miguel Ángel; Varela-Martínez, Diana Angélica; Socas-Rodríguez, Bárbara; Hernández-Borges, Javier

    2017-10-01

    Nanomaterials have found an important place in Analytical Chemistry and, in particular, in Separation Science. Among them, metal-organic frameworks, magnetic and non-magnetic nanoparticles, carbon nanotubes and graphene, as well as their combinations, are the most important nanomaterials that have been used up to now. Concerning capillary electromigration techniques, these nanomaterials have also been used as both pseudostationary phases in electrokinetic chromatography (EKC) and as stationary phases in microchip capillary electrophoresis (CE) and capillary electrochromatography (CEC), as a result of their interesting and particular properties. This review article pretends to provide a general and critical revision of the most recent applications of nanomaterials in this field (period 2010-2017). © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Ionization techniques in capillary electrophoresis-mass spectrometry: principles, design, and application.

    Science.gov (United States)

    Hommerson, Paul; Khan, Amjad M; de Jong, Gerhardus J; Somsen, Govert W

    2011-01-01

    A major step forward in the development and application of capillary electrophoresis (CE) was its coupling to ESI-MS, first reported in 1987. More than two decades later, ESI has remained the principal ionization technique in CE-MS, but a number of other ionization techniques have also been implemented. In this review the state-of-the-art in the employment of soft ionization techniques for CE-MS is presented. First the fundamentals and general challenges of hyphenating conventional CE and microchip electrophoresis with MS are outlined. After elaborating on the characteristics and role of ESI, emphasis is put on alternative ionization techniques including sonic spray ionization (SSI), thermospray ionization (TSI), atmospheric pressure chemical ionization (APCI), atmospheric pressure photoionization (APPI), matrix-assisted laser desorption ionization (MALDI) and continuous-flow fast atom bombardment (CF-FAB). The principle of each ionization technique is outlined and the experimental set-ups of the CE-MS couplings are described. The strengths and limitations of each ionization technique with respect to CE-MS are discussed and the applicability of the various systems is illustrated by a number of typical examples. Copyright © 2011 Wiley Periodicals, Inc.

  1. Indirect fluorescence detection of native amino acids in capillary zone electrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Kuhr, W.G.; Yeung, E.S.

    1988-09-01

    Amino acids are but one of several important classes of small chemical compounds in biological chemistry that have an inherent lack of analytically useful physical properties. Amino acids, peptides, fatty acids, sugars, many mono-, di-, and tricarboxylic acids, and phosphorylated intermediates in glycolysis and metabolism show little, if any, UV or visible absorption, fluorescence, or electrochemical activity. As the emphasis of biochemical research shifts to smaller samples where, for example, picomolar quantities of amino acids are analyzed in gas phase protein sequencing or in microliter samples of the extracellular fluid of the mammalian brain, the analytical problem becomes even more challenging due to the small volume of sample available for analysis. In this work, laser-induced fluorescence spectroscopy is performed on-column to detect the bands separated with capillary zone electrophoresis (CZE). CZE is an instrumental form of zone electrophoresis where chemical species are separated purely on the basis of their electrophoretic mobility, since no supporting gel is utilized. Both anions and cations can be separated in the same run because of the large electroosmotic flow generated in small diameter capillaries. This technique has already been used successfully in the rapid, efficient separation of dansyl-amino acids.

  2. ssDNA degradation along capillary electrophoresis process using a Tris buffer.

    Science.gov (United States)

    Ric, Audrey; Ong-Meang, Varravaddheay; Poinsot, Verena; Martins-Froment, Nathalie; Chauvet, Fabien; Boutonnet, Audrey; Ginot, Frédéric; Ecochard, Vincent; Paquereau, Laurent; Couderc, François

    2017-06-01

    Tris-Acetate buffer is currently used in the selection and the characterization of ssDNA by capillary electrophoresis (CE). By applying high voltage, the migration of ionic species into the capillary generates a current that induces water electrolysis. This phenomenon is followed by the modification of the pH and the production of Tris derivatives. By injecting ten times by capillary electrophoresis ssDNA (50 nM), the whole oligonucleotide was degraded. In this paper, we will show that the Tris buffer in the running vials is modified along the electrophoretic process by electrochemical reactions. We also observed that the composition of the metal ions changes in the running buffer vials. This phenomenon, never described in CE, is important for fluorescent ssDNA analysis using Tris buffer. The oligonucleotides are degraded by electrochemically synthesized species (present in the running Tris vials) until it disappears, even if the separation buffer in the capillary is clean. To address these issues, we propose to use a sodium phosphate buffer that we demonstrate to be electrochemically inactive. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Serum biochemistry and native protein electrophoresis in diarrheic calves with arthritis

    Directory of Open Access Journals (Sweden)

    Pekcan M.

    2012-01-01

    Full Text Available In this study, serum biochemistry and native protein electrophoresis in newborn calves with diarrhea and arthritis, were performed in order to evaluate the changes along with clinical findings for their possible application in the diagnosis and prognosis of disease. Based on clinical examination, animals were allotied into two groups comprising either diseased or healthy animals. Urea, creatinine, ALT, AST, LDH, albumin, total protein, glucose, total cholesterol, uric acid and iron levels were determined in the sera. Serum protein native polyacrilamide gel electrophoresis (nPAGE was performed followed by protein band ratio estimation supported with densitometry at 596 nm. Differences between the average mean of healthy and diseased animals were compared statistically (Kruskal-Walley test. In this study a decrease in serum glucose and cholesterol values (p<0.001, increase in urea, LDH levels and α1-and α2-globulin levels (p<0.01 and p<0.05 respectively were found to be associated with the disease. As a result, the observed significant changes in biochemical parameters and clinical investigation in calves, suggesting acute inflammation causing the decrease in glucose and increase in α-globulins, may be of prognostic value.

  4. Studies on lectins. XXXII. Application of affinity electrophoresis to the study of the interaction of lectins and their derivatives with sugars.

    Science.gov (United States)

    Horejsí, V; Tichá, M; Kocourek, J

    1977-09-29

    Affinity electrophoresis was used to study the sugar binding heterogeneity of lectins or their derivatives. Commercial and demetallized preparations of concanavalin A could be resolved by affinity electrophoresis into three components with different affinity to immobilized sugar. Similarly the Vicia cracca lectin obtained by affinity chromatography behaved on affinity gels as a mixture of active and inactive molecular species. Affinity electrophoresis has shown that the nonhemagglutinating acetylated lentil lectin and photo-oxidized or sulfenylated pea lectin retain their sugar binding properties; dissociation constants of saccharide complexes of these derivatives are similar to those of native lectins. The presence of specific immobilized sugar in the affinity gel improved the resolution of isolectins from Dolichos biflorus and Ricinus communis seeds.

  5. SIMULTANEOUS DTERMINATION OF CHROMATE AND AROMATIC HYDROCARBONS IN ENVIRONMENTAL SAMPLES BY CAPILLARY ELECTROPHORESIS

    Science.gov (United States)

    An analytical method was developed to determine simultaneously, the inorganic anion CrO2-4, and organic aromatic compounds including benzoate, 2-Cl-benzoate, phenol, m-cresol and o-/p-cresol by capillary electrophoresis (CE). Chromate and the aromatics were separated in a relativ...

  6. Feasibility of nonvolatile buffers in capillary electrophoresis-electrospray ionization-mass spectrometry of proteins

    NARCIS (Netherlands)

    Eriksson, Jonas H.C.; Mol, Roelof; Somsen, Govert W.; Hinrichs, Wouter L.J.; Frijlink, Henderik W.; de Jong, Gerhardus J.

    2004-01-01

    The combination of capillary electrophoresis (CE) and electrospray ionization-mass spectrometry (ESI-MS) via a triaxial interface was studied as a potential means for the characterization of intact proteins. To evaluate the possibility to use a nonvolatile electrolyte for CE, the effect of sodium

  7. Human muscle proteins: analysis by two-dimensional electrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Giometti, C.S.; Danon, M.J.; Anderson, N.G.

    1983-09-01

    Proteins from single frozen sections of human muscle were separated by two-dimensional gel electrophoresis and detected by fluorography or Coomassie Blue staining. The major proteins were identical in different normal muscles obtained from either sex at different ages, and in Duchenne and myotonic dystrophy samples. Congenital myopathy denervation atrophy, polymyositis, and Becker's muscular dystrophy samples, however, showed abnormal myosin light chain compositions, some with a decrease of fast-fiber myosin light chains and others with a decrease of slow-fiber light chains. These protein alterations did not correlate with any specific disease, and may be cause by generalized muscle-fiber damage.

  8. Recognition and management of common, rare, and novel serum protein electrophoresis and immunofixation interferences

    DEFF Research Database (Denmark)

    McCudden, Christopher R; Jacobs, Joannes F M; Keren, David

    2018-01-01

    Protein electrophoresis and immunofixation are subject to a variety of analytical interferences that may affect monoclonal protein diagnostics performed in the context of monoclonal gammopathies. Interferences include endogenous substances, such as hemoglobin and fibrinogen, and exogenous compounds...

  9. High resolution separations of charge variants and disulfide isomers of monoclonal antibodies and antibody drug conjugates using ultra-high voltage capillary electrophoresis with high electric field strength.

    Science.gov (United States)

    Henley, W Hampton; He, Yan; Mellors, J Scott; Batz, Nicholas G; Ramsey, J Michael; Jorgenson, James W

    2017-11-10

    Ultra-high voltage capillary electrophoresis with high electric field strength has been applied to the separation of the charge variants, drug conjugates, and disulfide isomers of monoclonal antibodies. Samples composed of many closely related species are difficult to resolve and quantify using traditional analytical instrumentation. High performance instrumentation can often save considerable time and effort otherwise spent on extensive method development. Ideally, the resolution obtained for a given CE buffer system scales with the square root of the applied voltage. Currently available commercial CE instrumentation is limited to an applied voltage of approximately 30kV and a maximum electric field strength of 1kV/cm due to design limitations. The instrumentation described here is capable of safely applying potentials of at least 120kV with electric field strengths over 2000V/cm, potentially doubling the resolution of the best conventional CE buffer/capillary systems while decreasing analysis time in some applications. Separations of these complex mixtures using this new instrumentation demonstrate the potential of ultra-high voltage CE to identify the presence of previously unresolved components and to reduce analysis time for complex mixtures of antibody variants and drug conjugates. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. High-resolution gel electrophoresis and sodium dodecyl sulphate-agarose gel electrophoresis on urine samples for qualitative analysis of proteinuria in dogs.

    Science.gov (United States)

    Giori, Luca; Tricomi, Flavia Marcella; Zatelli, Andrea; Roura, Xavier; Paltrinieri, Saverio

    2011-07-01

    The aims of the current study were to assess whether sodium dodecyl sulphate-agarose gel electrophoresis (SDS-AGE) and high-resolution electrophoresis (HRE) can identify dogs with a urinary protein-to-creatinine ratio (UPC ratio) >0.2 and whether HRE can provide preliminary information about the type of proteinuria, using SDS-AGE as a reference method. HRE and SDS-AGE were conducted on 87 urine samples classified according to the International Renal Interest Society as non-proteinuric (NP; UPC ratio: 0.51; 40/87). SDS-AGE and HRE were positive in 14 out of 32 and 3 out of 32 NP samples and in 52 out of 55 and 40 out of 55 samples with a UPC ratio >0.20, respectively. The concordance between HRE or SDS and UPC ratio was comparable (κ = 0.59; κ = 0.55). However, specificity (90%) and positive likelihood ratio (7.76) were higher for HRE than for SDS-AGE (56% and 2.16) while sensitivity was lower (73% vs. 94%). The analysis of HRE results revealed that a percentage of albumin >41.4% and an albumin/α(1)-globulin ratio (alb/α(1) ratio) >1.46 can identify samples classified by SDS-AGE as affected by glomerular proteinuria while a percentage of α(1)-globulin >40.8% and an alb/α(1) ratio HRE could misclassify samples with a UPC ratio higher or lower than 0.20. Therefore, UPC ratio must always be determined before conducting these tests. The percentage of albumin and α(1)-globulin or the alb/α(1) ratio determined by HRE can provide preliminary information about the origin of proteinuria.

  11. Multivalent weak electrolytes - risky background electrolytes for capillary zone electrophoresis

    Czech Academy of Sciences Publication Activity Database

    Beckers, J. L.; Boček, Petr

    2002-01-01

    Roč. 23, č. 12 (2002), s. 1942-1946 ISSN 0173-0835 R&D Projects: GA ČR GA203/99/0044; GA ČR GA203/02/0023; GA ČR GA203/01/0401; GA AV ČR IAA4031703; GA AV ČR IAA4031103 Institutional research plan: CEZ:AV0Z4031919 Keywords : background electrolytes * capillary zone electrophoresis * multivalent electrolytes Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 4.325, year: 2002

  12. Two-Dimensional Electrophoresis Study of Lactobacillus delbrueckii subsp. bulgaricus Thermotolerance

    OpenAIRE

    Gouesbet, Gwenola; Jan, Gwenael; Boyaval, Patrick

    2002-01-01

    The response of Lactobacillus delbrueckii subsp. bulgaricus cells to heat stress was studied by use of a chemically defined medium. Two-dimensional electrophoresis (2-DE) analysis was used to correlate the kinetics of heat shock protein (HSP) induction with cell recovery from heat injury. We demonstrated that enhanced viability, observed after 10 min at 65°C, resulted from the overexpression of HSP and from mechanisms not linked to protein synthesis. In order to analyze the thermoadaptation m...

  13. Counterbalancing hydrodynamic sample distortion effects increases resolution of free-flow zone electrophoresis.

    Science.gov (United States)

    Weber, G; Bauer, J

    1998-06-01

    On fractionation of highly heterogeneous protein mixtures, optimal resolution was achieved by forcing proteins to migrate through a preestablished pH gradient, until they entered a medium with a pH similar but not equal to their pIs. For this purpose, up to seven different media were pumped through the electrophoresis chamber so that they were flowing adjacently to each other, forming a pH gradient declining stepwise from the cathode to the anode. This gradient had a sufficiently strong band-focusing effect to counterbalance sample distortion effects of the flowing medium as proteins approached their isoelectric medium closer than 0.5 pH units. Continuous free-flow zone electrophoresis (FFZE) with high throughput capability was applicable if proteins did not precipitate or aggregate in these media. If components of heterogeneous protein mixtures had already started to precipitate or aggregate, in a medium with a pH exceeding their pI by more than 0.5 pH units, the application of interval modus and media forming flat pH gradients appeared advantageous.

  14. Procedural abortion rights: Ireland and the European Court of Human Rights.

    Science.gov (United States)

    Erdman, Joanna N

    2014-11-01

    The Irish Protection of Life During Pregnancy Act seeks to clarify the legal ground for abortion in cases of risk to life, and to create procedures to regulate women's access to services under it. This article explores the new law as the outcome of an international human rights litigation strategy premised on state duties to implement abortion laws through clear standards and procedural safeguards. It focuses specifically on the Irish law reform and the jurisprudence of the European Court of Human Rights, including A. B. and C. v. Ireland (2010). The article examines how procedural rights at the international level can engender domestic law reform that limits or expands women's access to lawful abortion services, serving conservative or progressive ends. Copyright © 2014 Reproductive Health Matters. Published by Elsevier Ltd. All rights reserved.

  15. The dilemma of contact: voluntary isolation and the impacts of gas exploitation on health and rights in the Kugapakori Nahua Reserve, Peruvian Amazon

    International Nuclear Information System (INIS)

    Napolitano, Dora A; Ryan, Aliya S S

    2007-01-01

    Many small groups of indigenous peoples in the Amazon basin avoid and resist direct encounters with outsiders. As far as we know, they do so because of appalling experiences in earlier encounters with national society. When contacted today, they are extremely vulnerable to introduced diseases and exploitation. In this paper we draw on our experience in the Kugapakori Nahua Reserve for isolated peoples in SE Peru to discuss some of the current debates about whether isolated peoples should be contacted and how best to respect their right to life, health, autonomy and territory. The remote headwater regions where isolated peoples sought refuge during the last century are increasingly sought after for resource extraction. In particular, the extraction of oil and gas is increasing throughout the Peruvian Amazon. In the second part of the paper we give some examples of how oil/gas companies and the energy sector in Peru have affected the well-being of the peoples in this reserve in the 21st century. If this trend is not reversed the impacts for isolated peoples will be irreparable

  16. The dilemma of contact: voluntary isolation and the impacts of gas exploitation on health and rights in the Kugapakori Nahua Reserve, Peruvian Amazon

    Science.gov (United States)

    Napolitano, Dora A.; Ryan, Aliya S. S.

    2007-10-01

    Many small groups of indigenous peoples in the Amazon basin avoid and resist direct encounters with outsiders. As far as we know, they do so because of appalling experiences in earlier encounters with national society. When contacted today, they are extremely vulnerable to introduced diseases and exploitation. In this paper we draw on our experience in the Kugapakori Nahua Reserve for isolated peoples in SE Peru to discuss some of the current debates about whether isolated peoples should be contacted and how best to respect their right to life, health, autonomy and territory. The remote headwater regions where isolated peoples sought refuge during the last century are increasingly sought after for resource extraction. In particular, the extraction of oil and gas is increasing throughout the Peruvian Amazon. In the second part of the paper we give some examples of how oil/gas companies and the energy sector in Peru have affected the well-being of the peoples in this reserve in the 21st century. If this trend is not reversed the impacts for isolated peoples will be irreparable.

  17. Comparative analyses of amplicon migration behavior in differing denaturing gradient gel electrophoresis (DGGE) systems

    Science.gov (United States)

    Thornhill, D. J.; Kemp, D. W.; Sampayo, E. M.; Schmidt, G. W.

    2010-03-01

    Denaturing gradient gel electrophoresis (DGGE) is commonly utilized to identify and quantify microbial diversity, but the conditions required for different electrophoretic systems to yield equivalent results and optimal resolution have not been assessed. Herein, the influence of different DGGE system configuration parameters on microbial diversity estimates was tested using Symbiodinium, a group of marine eukaryotic microbes that are important constituents of coral reef ecosystems. To accomplish this, bacterial clone libraries were constructed and sequenced from cultured isolates of Symbiodinium for the ribosomal DNA internal transcribed spacer 2 (ITS2) region. From these, 15 clones were subjected to PCR with a GC clamped primer set for DGGE analyses. Migration behaviors of the resulting amplicons were analyzed using a range of conditions, including variation in the composition of the denaturing gradient, electrophoresis time, and applied voltage. All tests were conducted in parallel on two commercial DGGE systems, a C.B.S. Scientific DGGE-2001, and the Bio-Rad DCode system. In this context, identical nucleotide fragments exhibited differing migration behaviors depending on the model of apparatus utilized, with fragments denaturing at a lower gradient concentration and applied voltage on the Bio-Rad DCode system than on the C.B.S. Scientific DGGE-2001 system. Although equivalent PCR-DGGE profiles could be achieved with both brands of DGGE system, the composition of the denaturing gradient and application of electrophoresis time × voltage must be appropriately optimized to achieve congruent results across platforms.

  18. Determination of benzimidazoles in meat samples by capillary zone electrophoresis tandem mass spectrometry following dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Tejada-Casado, Carmen; Moreno-González, David; Lara, Francisco J; García-Campaña, Ana M; Del Olmo-Iruela, Monsalud

    2017-03-24

    A novel method based on capillary zone electrophoresis-tandem mass spectrometry has been proposed and validated for the identification and simultaneous quantification of twelve benzimidazoles in meat samples. Electrophoretic separation was carried out using 500mM formic acid (pH 2.2) as background electrolyte and applying a voltage of 25kV at 25°C. In order to improve the sensitivity, stacking mode injection was applied, using as injection solvent a mixture of 30:70 acetonitrile/water at 50mbar for 75s. Sensitivity enhancement factors from 74 to 317 were obtained under these conditions. Detection using an ion trap as analyzer, operating in multiple reactions monitoring mode was employed. The main MS/MS parameters as well as the composition of the sheath liquid and other electrospray variables were optimized in order to obtain the highest sensitivity and precision in conjunction with an unequivocal identification. The method was applied to poultry and pork muscle samples. The deproteinization of samples and extraction of benzimidazoles was carried out with acetonitrile. MgSO 4 and NaCl were added as salting-out agents. Subsequently, dispersive liquid-liquid microextraction was applied as clean up procedure. The organic layer (acetonitrile, used as dispersant) containing the benzimidazoles was mixed with the extractant (chloroform) and both were injected in water, producing a cloudy solution. Recoveries for fortified samples were higher than 70%, with relative standard deviations lower than 16% were obtained in all cases. The limits of detection were below 3μgkg -1 , demonstrating the applicability of this fast, simple, and environmentally friendly method. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Highly sensitive capillary electrophoresis-mass spectrometry for rapid screening and accurate quantitation of drugs of abuse in urine.

    Science.gov (United States)

    Kohler, Isabelle; Schappler, Julie; Rudaz, Serge

    2013-05-30

    The combination of capillary electrophoresis (CE) and mass spectrometry (MS) is particularly well adapted to bioanalysis due to its high separation efficiency, selectivity, and sensitivity; its short analytical time; and its low solvent and sample consumption. For clinical and forensic toxicology, a two-step analysis is usually performed: first, a screening step for compound identification, and second, confirmation and/or accurate quantitation in cases of presumed positive results. In this study, a fast and sensitive CE-MS workflow was developed for the screening and quantitation of drugs of abuse in urine samples. A CE with a time-of-flight MS (CE-TOF/MS) screening method was developed using a simple urine dilution and on-line sample preconcentration with pH-mediated stacking. The sample stacking allowed for a high loading capacity (20.5% of the capillary length), leading to limits of detection as low as 2 ng mL(-1) for drugs of abuse. Compound quantitation of positive samples was performed by CE-MS/MS with a triple quadrupole MS equipped with an adapted triple-tube sprayer and an electrospray ionization (ESI) source. The CE-ESI-MS/MS method was validated for two model compounds, cocaine (COC) and methadone (MTD), according to the Guidance of the Food and Drug Administration. The quantitative performance was evaluated for selectivity, response function, the lower limit of quantitation, trueness, precision, and accuracy. COC and MTD detection in urine samples was determined to be accurate over the range of 10-1000 ng mL(-1) and 21-1000 ng mL(-1), respectively. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. A neutral glyoxal gel electrophoresis method for the detection and semi-quantitation of DNA single-strand breaks.

    Science.gov (United States)

    Pachkowski, Brian; Nakamura, Jun

    2013-01-01

    Single-strand breaks are among the most prevalent lesions found in DNA. Traditional electrophoretic methods (e.g., the Comet assay) used for investigating these lesions rely on alkaline conditions to denature DNA prior to electrophoresis. However, the presence of alkali-labile sites in DNA can result in the introduction of additional single-strand breaks upon alkali treatment during DNA sample processing. Herein, we describe a neutral glyoxal gel electrophoresis assay which is based on alkali-free DNA denaturation and is suitable for qualitative and semi-quantitative analyses of single-strand breaks in DNA isolated from different organisms.

  1. Recent advances in combination of capillary electrophoresis with mass spectrometry: Methodology and theory

    Czech Academy of Sciences Publication Activity Database

    Klepárník, Karel

    2015-01-01

    Roč. 36, č. 1 (2015), s. 159-179 ISSN 0173-0835 R&D Projects: GA ČR(CZ) GA14-28254S Institutional support: RVO:68081715 Keywords : capillary electrophoresis * electrospray * mass spectrometry * Microfluidic devices Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 2.482, year: 2015

  2. Electrophoresis microchip with integrated waveguides for simultaneous native UV fluorescence and absorbance detection

    DEFF Research Database (Denmark)

    Ohlsson, Pelle Daniel; Sala, Olga Ordeig; Mogensen, Klaus Bo

    2009-01-01

    Simultaneous label-free detection of UV absorbance and native UV-excited fluorescence in an electrophoresis microchip is presented. UV transparent integrated waveguides launch light at a wavelength of 254 nm from a mercury lamp along the length of a 1-mm. long detection cell. Transmitted UV light...

  3. pI-Control in comparative fluorescence gel electrophoresis (CoFGE) using amphoteric azo dyes

    Czech Academy of Sciences Publication Activity Database

    Hanneken, M.; Šlais, Karel; König, S.

    2015-01-01

    Roč. 3, JUN (2015), s. 221-228 ISSN 2352-3409 Institutional support: RVO:68081715 Keywords : 2D-PAGE * CoFGE * Gel electrophoresis Subject RIV: CB - Analytical Chemistry, Separation http://www.sciencedirect.com/science/article/pii/S2352340915000414

  4. Product-selective blot: a technique for measuring enzyme activities in large numbers of samples and in native electrophoresis gels

    International Nuclear Information System (INIS)

    Thompson, G.A.; Davies, H.M.; McDonald, N.

    1985-01-01

    A method termed product-selective blotting has been developed for screening large numbers of samples for enzyme activity. The technique is particularly well suited to detection of enzymes in native electrophoresis gels. The principle of the method was demonstrated by blotting samples from glutaminase or glutamate synthase reactions into an agarose gel embedded with ion-exchange resin under conditions favoring binding of product (glutamate) over substrates and other substances in the reaction mixture. After washes to remove these unbound substances, the product was measured using either fluorometric staining or radiometric techniques. Glutaminase activity in native electrophoresis gels was visualized by a related procedure in which substrates and products from reactions run in the electrophoresis gel were blotted directly into a resin-containing image gel. Considering the selective-binding materials available for use in the image gel, along with the possible detection systems, this method has potentially broad application

  5. Determination of Na and Al Ions in Semiconductor Cleaning Solution Using Capillary Electrophoresis

    International Nuclear Information System (INIS)

    Lee, H. P.; Lim, H. B.

    2003-01-01

    The most common process chemical used in the manufacturing process is a standard cleaning (SC) solution, a mixture of ammonia and hydrogen peroxide in deionized water. Since the purity of the SC solution used in the process has been required to the level of sub-ppb range, accurate and reliable determination of ionic contaminants becomes increasingly difficult. In order to satisfy the requirement of impurity control, inductively coupled plasma-mass spectrometer (ICP-MS), graphite furnace atomic absorption spectrometer (GFAAS), and ion chromatography (IC) are currently the most common analytical instruments used in the process. However, those instruments are not designed for on-line monitoring but rather for off-line analysis. Recently, separation and detection of various particles, such as cells and nanoparticles, with capillary electrophoresis (CE) was reported, although the application of CE has been mostly limited to organic or biological samples. Capillary electrophoresis has been emerging as an alternative to ICPAES and AAS for trace metal analysis

  6. Interfacing capillary electrophoresis with inductively coupled plasma mass spectrometry for redox speciation of plutonium

    International Nuclear Information System (INIS)

    Ambard, C.; Delorme, A.; Baglan, N.; Aupiais, J.; Pointurier, F.; Madic, C.

    2005-01-01

    A robust and efficient interface between a capilary electrophoresis (CE) and an ICP-MS for actinide speciation studies was developed. This interface was made of two stainless steel T-shape pieces connected to the ICP-MS through a PFA-50 nebulizer. Fast separations (typically in less than 15 min) were obtained. The performances of the technique in terms of chemical separations carried out by the capillary electrophoresis and in terms of detection limits were investigated. Concerning the detection limit of the CE-ICP-MS system for plutonium, it was determined as 5 x 10 -10 mol L -1 or 9 x 10 -18 mol under our injection conditions. The coupling enables to separate at least three (III, V and VI) of the four plutonium oxidation states which can exist in aqueous solutions and to monitor oxidation and reduction processes. (orig.)

  7. Quality monitoring methods of initial and terminal manufacture of LiFePO4 based lithium ion batteries by capillary electrophoresis.

    Science.gov (United States)

    Xie, Xia; Yang, Yang; Zhou, Henghui; Li, Meixian; Zhu, Zhiwei

    2018-03-01

    Magnetic impurities of lithium ion battery degrade both the capacity and cycling rates, even jeopardize the safety of the battery. During the material manufacture of LiFePO 4 , two opposite and extreme cases (trace impurity Fe(II) with high content of Fe(III) background in FePO 4 of initial end and trace Fe(III) with high content of Fe(II) background in LiFePO 4 of terminal end) can result in the generation of magnetic impurities. Accurate determination of impurities and precise evaluation of raw material or product are necessary to ensure reliability, efficiency and economy in lithium ion battery manufacture. Herein, two kinds of rapid, simple, and sensitive capillary electrophoresis (CE) methods are proposed for quality monitoring of initial and terminal manufacture of LiFePO 4 based lithium ion batteries. The key to success includes the smart use of three common agents 1,10-phenanthroline (phen), EDTA and cetyltrimethyl ammonium bromide (CTAB) in sample solution or background electrolyte (BGE), as well as sample stacking technique of CE feature. Owing to the combination of field-enhanced sample injection (FESI) technique with high stacking efficiency, detection limits of 2.5nM for Fe(II) and 0.1μM for Fe(III) were obtained corresponding to high content of Fe(III) and Fe(II), respectively. The good recoveries and reliability demonstrate that the developed methods are accurate approaches for quality monitoring of LiFePO 4 manufacture. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Use of ion-pairing reagent for improving iodine speciation analysis in seaweed by pressure-driven capillary electrophoresis and ultraviolet detection.

    Science.gov (United States)

    Sun, Jiannan; Wang, Dan; Cheng, Heyong; Liu, Jinhua; Wang, Yuanchao; Xu, Zigang

    2015-01-30

    This study achieved resolution improvement for iodine speciation in the presence of an ion-pairing reagent by a pressure-driven capillary electrophoresis (CE) system. Addition of 0.01mM tetrabutyl ammonium hydroxide (TBAH) as the ion-pairing reagent into the electrophoretic buffer resulted in the complete separation of four iodine species (I(-), IO3(-), mono-iodothyrosine-MIT and di-iodothyrosine-DIT), because of the electrostatic interaction between TBAH and the negatively charged analytes. A +16kV separation voltage was applied along the separation capillary (50μm i.d., 80cm total and 60cm effective) with the inlet grounded. The detection wavelength was fixed at 210nm, and the pressure-driven flow rate was set at 0.12mLmin(-1) with an injected volume of 2μL. The optimal electrolyte consisted of 2mM borate, 2mM TBAH and 80% methanol with pH adjusted to 8.5. Baseline separation of iodine species was achieved within 7min. The detection limits for I(-), IO3(-), MIT and DIT were 0.052, 0.040, 0.032 and 0.025mgL(-1), respectively. The relative standard deviations of peak heights and areas were all below 3% for 5mgL(-1) and 5% for 1mgL(-1). Application of the proposed method was demonstrated by speciation analysis of iodine in two seaweed samples. The developed method offered satisfactory recoveries in the 91-99% range and good precisions (iodine speciation in environmental, food and biological samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Reserve selection with land market feedbacks.

    Science.gov (United States)

    Butsic, Van; Lewis, David J; Radeloff, Volker C

    2013-01-15

    How to best site reserves is a leading question for conservation biologists. Recently, reserve selection has emphasized efficient conservation: maximizing conservation goals given the reality of limited conservation budgets, and this work indicates that land market can potentially undermine the conservation benefits of reserves by increasing property values and development probabilities near reserves. Here we propose a reserve selection methodology which optimizes conservation given both a budget constraint and land market feedbacks by using a combination of econometric models along with stochastic dynamic programming. We show that amenity based feedbacks can be accounted for in optimal reserve selection by choosing property price and land development models which exogenously estimate the effects of reserve establishment. In our empirical example, we use previously estimated models of land development and property prices to select parcels to maximize coarse woody debris along 16 lakes in Vilas County, WI, USA. Using each lake as an independent experiment, we find that including land market feedbacks in the reserve selection algorithm has only small effects on conservation efficacy. Likewise, we find that in our setting heuristic (minloss and maxgain) algorithms perform nearly as well as the optimal selection strategy. We emphasize that land market feedbacks can be included in optimal reserve selection; the extent to which this improves reserve placement will likely vary across landscapes. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. Probable nosocomial transmission of listeriosis in neonates.

    Science.gov (United States)

    Lazarus, C; Leclercq, A; Lecuit, M; Vaillant, V; Coignard, B; Blanchard, H; Novakova, I; Astagneau, P

    2013-10-01

    Listeria monocytogenes was isolated in two neonates born consecutively in the same hospital in France. The isolates had indistinguishable pulsed-field electrophoresis profiles. Retrospective epidemiological investigations found no evidence of a food-borne or environmental source. Infection control protocols and decontamination processes were in accordance with standard recommendations. The timing of onset of these infections within the same maternity unit, and the similarity of pulsed-field gel electrophoresis profiles suggests cross-infection of L. monocytogenes between the two neonates. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  11. Separation of hydrolytically active components of cellulase from Myrothecium verrucaria by starch gel electrophoresis

    NARCIS (Netherlands)

    Ritter, F.J.; Prins-van der Meulen, P.Y.F.; Marel, T. van der

    1968-01-01

    Using starch gel electrophoresis according to Smithies, desalted crude cellulase from Myrothecium verrucqria was separated into at least 12 protein zones. These were tested on their activity towards p-nitrophenyl-β-D-glucoside, sodium carboxymethylcellulose and α-cellulose. They were all

  12. Interaction between p-dihydroxyborylphenylalanine and adrenaline studied by a zone electrophoresis

    International Nuclear Information System (INIS)

    Kitaoka, Y.; Kobayashi, M.

    2000-01-01

    In order to develop a new boron carrier, we studied the interaction between p-dihydroxyborylphenylalanine (p-BPA) and adrenaline (Adre.) by a zone electrophoresis, paper chromatography, and infrared-spectroscopy. It was found that the complex of p-BPA with Adre. was stable near neutral solutions and decomposed under acidic solutions. The chemical nature of the complex was compared with those of the complexes of p-BPA with organic acids. (author)

  13. Interaction between p-dihydroxyborylphenylalanine and adrenaline studied by a zone electrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Kitaoka, Y.; Kobayashi, M. [Kyoto Univ., Kumatori, Osaka (Japan). Research Reactor Inst

    2000-10-01

    In order to develop a new boron carrier, we studied the interaction between p-dihydroxyborylphenylalanine (p-BPA) and adrenaline (Adre.) by a zone electrophoresis, paper chromatography, and infrared-spectroscopy. It was found that the complex of p-BPA with Adre. was stable near neutral solutions and decomposed under acidic solutions. The chemical nature of the complex was compared with those of the complexes of p-BPA with organic acids. (author)

  14. Quantitative Experimental Determination of Primer-Dimer Formation Risk by Free-Solution Conjugate Electrophoresis

    Science.gov (United States)

    Desmarais, Samantha M.; Leitner, Thomas; Barron, Annelise E.

    2012-01-01

    DNA barcodes are short, unique ssDNA primers that “mark” individual biomolecules. To gain better understanding of biophysical parameters constraining primer-dimer formation between primers that incorporate barcode sequences, we have developed a capillary electrophoresis method that utilizes drag-tag-DNA conjugates to quantify dimerization risk between primer-barcode pairs. Results obtained with this unique free-solution conjugate electrophoresis (FSCE) approach are useful as quantitatively precise input data to parameterize computation models of dimerization risk. A set of fluorescently labeled, model primer-barcode conjugates were designed with complementary regions of differing lengths to quantify heterodimerization as a function of temperature. Primer-dimer cases comprised two 30-mer primers, one of which was covalently conjugated to a lab-made, chemically synthesized poly-N-methoxyethylglycine drag-tag, which reduced electrophoretic mobility of ssDNA to distinguish it from ds primer-dimers. The drag-tags also provided a shift in mobility for the dsDNA species, which allowed us to quantitate primer-dimer formation. In the experimental studies, pairs of oligonucleotide primer-barcodes with fully or partially complementary sequences were annealed, and then separated by free-solution conjugate CE at different temperatures, to assess effects on primer-dimer formation. When less than 30 out of 30 basepairs were bonded, dimerization was inversely correlated to temperature. Dimerization occurred when more than 15 consecutive basepairs formed, yet non-consecutive basepairs did not create stable dimers even when 20 out of 30 possible basepairs bonded. The use of free-solution electrophoresis in combination with a peptoid drag-tag and different fluorophores enabled precise separation of short DNA fragments to establish a new mobility shift assay for detection of primer-dimer formation. PMID:22331820

  15. Electrophoresis in nanochannels: brief review and speculation

    Directory of Open Access Journals (Sweden)

    Santiago Juan G

    2006-11-01

    Full Text Available Abstract The relevant physical phenomena that dominate electrophoretic transport of ions and macromolecules within long, thin nanochannels are reviewed, and a few papers relevant to the discussion are cited. Sample ion transport through nanochannels is largely a function of their interaction with electric double layer. For small ions, this coupling includes the net effect of the external applied field, the internal field of the double layer, and the non-uniform velocity of the liquid. Adsorption/desorption kinetics and the effects of surface roughness may also be important in nanochannel electrophoresis. For macromolecules, the resulting motion is more complex as there is further coupling via steric interactions and perhaps polarization effects. These complex interactions and coupled physics represent a valuable opportunity for novel electrophoretic and chromatographic separations.

  16. Analytical applications of the electrochemiluminescence of tris(2,2'-bipyridyl)ruthenium(II) coupled to capillary/microchip electrophoresis: A review

    Energy Technology Data Exchange (ETDEWEB)

    Su Ming; Wei Wei [School of Chemistry and Chemical Engineering, Southeast University, Nanjing, 211189 (China); Liu Songqin, E-mail: liusq@seu.edu.cn [School of Chemistry and Chemical Engineering, Southeast University, Nanjing, 211189 (China)

    2011-10-17

    Graphical abstract: The mechanism of Ru(bpy){sub 3}{sup 2+} electrochemiluminescence, addition mode of Ru(bpy){sub 3}{sup 2+}, recent applications of capillary electrophoresis coupled with electrochemiluminescent detection in drug and other substrates analysis are reviewed. - Abstract: A comprehensive review on the development of analytical methods, by coupling electrochemiluminescence (ECL) detection with capillary electrophoresis (CE) and microchip electrophoresis (ME), is presented. After the description of the basic mechanism of ECL, the addition mode of luminescence reagent in CE-ECL system has been discussed. The analytical applications of the CE-ECL technique in terms of different analytes are also given. Due to the importance of ME as a separation method for the present and future, the ME detection methods based on ECL are considered in a relatively detailed way. Finally, possible trends for CE/ME-ECL in the near future are discussed.

  17. Sensitive detection of malachite green and crystal violet by nonlinear laser wave mixing and capillary electrophoresis.

    Science.gov (United States)

    Maxwell, Eric J; Tong, William G

    2016-05-01

    An ultrasensitive label-free antibody-free detection method for malachite green and crystal violet is presented using nonlinear laser wave-mixing spectroscopy and capillary zone electrophoresis. Wave-mixing spectroscopy provides a sensitive absorption-based detection method for trace analytes. This is accomplished by forming dynamic gratings within a sample cell, which diffracts light to create a coherent laser-like signal beam with high optical efficiency and high signal-to-noise ratio. A cubic dependence on laser power and square dependence on analyte concentration make wave mixing sensitive enough to detect molecules in their native form without the use of fluorescent labels for signal enhancement. A 532 nm laser and a 635 nm laser were used for malachite green and crystal violet sample excitation. The use of two lasers of different wavelengths allows the method to simultaneously detect both analytes. Selectivity is obtained through the capillary zone electrophoresis separation, which results in characteristic migration times. Measurement in capillary zone electrophoresis resulted in a limit of detection of 6.9 × 10(-10)M (2.5 × 10(-19) mol) for crystal violet and 8.3 × 10(-11)M (3.0 × 10(-20) mol) for malachite green at S/N of 2. Copyright © 2016. Published by Elsevier B.V.

  18. Children's judgments about ownership rights and body rights: Evidence for a common basis.

    Science.gov (United States)

    Van de Vondervoort, Julia W; Meinz, Paul; Friedman, Ori

    2017-03-01

    We report two experiments supporting the theory that children's understanding of ownership rights is related to their notions of body rights. Experiment 1 investigated 4- to 7-year-olds' (N=123) developing sensitivity to physical contact in their judgments about the acceptability of behaving in relation to owned objects and body parts. Experiment 2 used a simpler design to investigate this in 3- and 4-year-olds (N=112). Findings confirmed two predictions of the theory. First, in both experiments, children's judgments about ownership and body rights were similarly affected by physical contact. Second, judgments about both kinds of rights were yoked in development; age-related changes in judgments about ownership rights were paralleled by changes in judgments about body rights. Our findings have additional import for theories of ownership rights because they suggest that physical contact may be a crucial factor in whether behaviors targeting property are judged to be permissible. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Active airborne contamination control using electrophoresis

    International Nuclear Information System (INIS)

    Veatch, B.D.

    1994-01-01

    In spite of our best efforts, radioactive airborne contamination continues to be a formidable problem at many of the Department of Energy (DOE) weapons complex sites. For workers that must enter areas with high levels of airborne contamination, personnel protective equipment (PPE) can become highly restrictive, greatly diminishing productivity. Rather than require even more restrictive PPE for personnel in some situations, the Rocky Flats Plant (RFP) is actively researching and developing methods to aggressively combat airborne contamination hazards using electrophoretic technology. With appropriate equipment, airborne particulates can be effectively removed and collected for disposal in one simple process. The equipment needed to implement electrophoresis is relatively inexpensive, highly reliable, and very compact. Once airborne contamination levels are reduced, less PPE is required and a significant cost savings may be realized through decreased waste and maximized productivity. Preliminary ''cold,'' or non-radioactive, testing results at the RFP have shown the technology to be effective on a reasonable scale, with several potential benefits and an abundance of applications

  20. Dual-wavelength recording, a simple algorithm to eliminate interferences due to UV-absorbing substances in capillary electrophoresis.

    Science.gov (United States)

    Seaux, Liesbeth; Van Houcke, Sofie; Dumoulin, Els; Fiers, Tom; Lecocq, Elke; Delanghe, Joris R

    2014-08-01

    Analytical interferences have been described due to the presence of various exogenous UV-absorbing substances in serum. Iodine-based X-ray contrast agents and various antibiotics have been reported to interfere with interpretation of serum protein pherograms, resulting in false diagnosis of paraproteinemia. In the present study, we have explored the possibility of measuring UV absorbance at two distinct wavelengths (210 and 246 nm) to distinguish between true and false paraproteins on a Helena V8 clinical electrophoresis instrument. This study demonstrates that most substances potentially interfering with serum protein electrophoresis show UV-absorption spectra that are distinct from those of serum proteins. Scanning at 246 nm allows detection of all described interfering agents. Comparing pherograms recorded at both wavelengths (210 and 246 nm) enables to distinguish paraproteins from UV-absorbing substances. In case of a true paraprotein, the peak with an electrophoretic mobility in the gamma-region decreases, whereas the X-ray contrast media and antibiotics show an increased absorption when compared to the basic setting (210 nm). The finding of iodine-containing contrast media interfering with serum protein electrophoresis is not uncommon. In a clinical series, interference induced by contrast media was reported in 54 cases (of 13 237 analyses), corresponding with a prevalence of 0.4%. In the same series, 1631 true paraproteins (12.3%) were detected. Implementation of the proposed algorithm may significantly improve the interpretation of routine electrophoresis results. However, attention should still be paid to possible interference due to presence of atypical proteins fractions (e.g., tumor markers, C3). © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Pulsed-field gel electrophoresis (PFGE): application in population structure studies of bovine mastitis-causing streptococci.

    Science.gov (United States)

    Santos-Sanches, Ilda; Chambel, Lélia; Tenreiro, Rogério

    2015-01-01

    Pulsed-field gel electrophoresis (PFGE) separates large DNA molecules by the use of an alternating electrical field, such that greater size resolution can be obtained when compared to normal agarose gel electrophoresis. PFGE is often employed to track pathogens and is a valuable typing scheme to detect and differentiate strains. Particularly, the contour-clamped homogeneous electric field (CHEF) PFGE system is considered to be the gold standard for use in epidemiological studies of many bacterial pathogens. Here we describe a PFGE protocol that was applicable to the study of bovine streptococci, namely, Streptococcus agalactiae (group B Streptococcus, GBS), Streptococcus dysgalactiae subsp. dysgalactiae (group C Streptococcus, GCS), and Streptococcus uberis-which are relevant pathogens causing mastitis, a highly prevalent and costly disease in dairy industry due to antibiotherapy and loss in milk production.

  2. Automation and integration of polymerase chain reaction with capillary electrophoresis for high throughput genotyping and disease diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, N.

    1999-02-12

    Genotyping is to detect specific loci in the human genome. These loci provide important information for forensic testing, construction of genetic linkage maps, gene related disease diagnosis and pharmacogenetic research. Genotyping is becoming more and more popular after these loci can be easily amplified by polymerase chain reaction (PCR). Capillary electrophoresis has its unique advantages for DNA analysis due to its fast heat dissipation and ease of automation. Four projects are described in which genotyping is performed by capillary electrophoresis emphasizing different aspects. First, the author demonstrates a principle to determine the genotype based on capillary electrophoresis system. VNTR polymorphism in the human D1S80 locus was studied. Second, the separation of four short tandem repeat (STR) loci vWF, THO1, TPOX and CSF1PO (CTTv) by using poly(ethylene oxide) (PEO) was studied in achieving high resolution and preventing rehybridization of the DNA fragments. Separation under denaturing, non-denaturing conditions and at elevated temperature was discussed. Third, a 250 {micro}m i.d., 365 {micro}m o.d. fused silica capillary was used as the microreactor for PCR. Fourth, direct PCR from blood was studied to simplify the sample preparation for genotyping to minimum.

  3. A new multiphasic buffer system for benzyldimethyl-n-hexadecylammonium chloride polyacrylamide gel electrophoresis of proteins providing efficient stacking.

    Science.gov (United States)

    Kramer, Michael L

    2006-02-01

    Acidic PAGE systems using cationic detergents such as benzyldimethyl-n-hexadecylammonium chloride (16-BAC) or CTAB have proven useful for the detection of methoxy esters sensitive to alkaline pH, resolving basic proteins such as histones and membrane proteins. However, the interesting phosphate-based system suffered from poor stacking, resulting in broadened bands and long running times. Therefore, a new 16-BAC PAGE system based on the theory of moving boundary electrophoresis with properties comparable to the classical SDS-PAGE system was designed. As a result a new multiphasic analytical 16-BAC PAGE system providing efficient stacking and significantly shorter running times is presented here. It is based on acetic acid and methoxyacetic acid as common ion constituents. This PAGE system takes advantage of the additional counter stacking effect due to a cross boundary electrophoresis system resulting from the selected buffer constituents. Furthermore, the concentration of 16-BAC was optimized by determining its previously unknown CMC. Due to efficient focusing of the introduced tracking dye, methyl green, termination of electrophoresis can now be more easily followed as compared to the Schlieren line.

  4. Stacking and discontinuous buffers in capillary zone electrophoresis.

    Science.gov (United States)

    Shihabi, Z K

    2000-08-01

    Discontinuous buffers for capillary zone electrophoresis (CZE) can be used under less rigid conditions compared to those for isotachophoresis for stacking. They can be prepared simply by modifying the sample itself, either by addition of small inorganic ions, low conductivity diluents, or both, and also by adjusting its pH, meanwhile injecting a large volume on the capillary. Zwitterionic and organic-based buffers such as triethanolamine and tris(hydroxymethyl)aminomethane (Tris) are well suited for stacking due to their low conductivity, provided the buffer is discontinuous as demonstrated here. A simple mechanism based on discontinuous buffers is described to explain many of the observed stacking types in CZE, pointing out the many similarities to transient isotachophoresis.

  5. HIPAA's Individual Right of Access to Genomic Data: Reconciling Safety and Civil Rights.

    Science.gov (United States)

    Evans, Barbara J

    2018-01-04

    In 2014, the United States granted individuals a right of access to their own laboratory test results, including genomic data. Many observers feel that this right is in tension with regulatory and bioethical standards designed to protect the safety of people who undergo genomic testing. This commentary attributes this tension to growing pains within an expanding federal regulatory program for genetic and genomic testing. The Genetic Information Nondiscrimination Act of 2008 expanded the regulatory agenda to encompass civil rights and consumer safety. The individual access right, as it applies to genomic data, is best understood as a civil-rights regulation. Competing regulatory objectives-safety and civil rights-were not successfully integrated during the initial rollout of genomic civil-rights regulations after 2008. Federal law clarifies how to prioritize safety and civil rights when the two come into conflict, although with careful policy design, the two need not collide. This commentary opens a dialog about possible solutions to advance safety and civil rights together. Copyright © 2017 American Society of Human Genetics. Published by Elsevier Inc. All rights reserved.

  6. ANALYSIS OF GLYCANS DERIVED FROM GLYCOCONJUGATES BY CAPILLARY ELECTROPHORESIS-MASS SPECTROMETRY

    Science.gov (United States)

    Mechref, Yehia

    2012-01-01

    The high structural variation of glycan derived from glycoconjugates, which substantially increases with the molecular size of a protein, contributes to the complexity of glycosylation patterns commonly associated with glycoconjugates. In the case of glycoproteins, such variation originates from the multiple glycosylation sites of proteins and the number of glycan structures associated with each site (microheterogeneity). The ability to comprehensively characterize highly complex mixture of glycans has been analytically stimulating and challenging. Although the most powerful mass spectrometric (MS) and tandem MS techniques are capable of providing a wealth of structural information, they are still not able to readily identify isomeric glycan structures without high order tandem MS (MSn). The analysis of isomeric glycan structures has been attained using several separation methods, including high-pH anion exchange chromatography (HPAEC), hydrophilic interaction chromatography (HILIC) and gas chromatography (GC). However, capillary electrophoresis (CE) and microfluidics capillary electrophoresis (MCE) offer high separation efficiency and resolutions, allowing the separation of closely related glycan structures. Therefore, interfacing CE and MCE to MS is a powerful analytical approach, allowing potentially comprehensive and sensitive analysis of complex glycan samples. This review describes and discusses the utility of different CE and MCE approaches in the structural characterization of glycoproteins and the feasibility of interfacing these approaches to mass spectrometry. PMID:22180203

  7. Denaturing gradient gel electrophoresis

    International Nuclear Information System (INIS)

    Kocherginskaya, S.A.; Cann, I.K.O.; Mackie, R.I.

    2005-01-01

    It is worthwhile considering that only some 30 species make up the bulk of the bacterial population in human faeces at any one time based on the classical cultivation-based approach. The situation in the rumen is similar. Thus, it is practical to focus on specific groups of interest within the complex community. These may be the predominant or the most active species, specific physiological groups or readily identifiable (genetic) clusters of phylogenetically related organisms. Several 16S rDNA fingerprinting techniques can be invaluable for selecting and monitoring sequences or phylogenetic groups of interest and are described below. Over the past few decades, considerable attention was focussed on the identification of pure cultures of microbes on the basis of genetic polymorphisms of DNA encoding rRNA such as ribotyping, amplified fragment length polymorphism and randomly amplified polymorphic DNA. However, many of these methods require prior cultivation and are less suitable for use in analysis of complex mixed populations although important in describing cultivated microbial diversity in molecular terms. Much less attention was given to molecular characterization of complex communities. In particular, research into diversity and community structure over time has been revolutionized by the advent of molecular fingerprinting techniques for complex communities. Denaturing or temperature gradient gel electrophoresis (DGGE/TGGE) methods have been successfully applied to the analysis of human, pig, cattle, dog and rodent intestinal populations

  8. Antidepressants: Selecting One That's Right for You

    Science.gov (United States)

    Antidepressants: Selecting one that's right for you Confused by the choice in antidepressants? With persistence, you and your doctor should find one that works so ... Foundation for Medical Education and Research (MFMER). All rights reserved.

  9. Improvement of fragment and primer selection for mutation detection by denaturing gradient gel electrophoresis

    NARCIS (Netherlands)

    Wu, Y; Hayes, VM; Osinga, J; Mulder, IM; Looman, MWG; Buys, CHCM; Hofstra, RMW

    1998-01-01

    Denaturing gradient gel electrophoresis (DGGE) is one of the most powerful methods for mutation detection currently available. For successful application the appropriate selection of PCR fragments and PCR primers is crucial. The sequence of interest should always be within the domain with the lowest

  10. AN IMAGE-ANALYSIS TECHNIQUE FOR DETECTION OF RADIATION-INDUCED DNA FRAGMENTATION AFTER CHEF ELECTROPHORESIS

    NARCIS (Netherlands)

    ROSEMANN, M; KANON, B; KONINGS, AWT; KAMPINGA, HH

    CHEF-electrophoresis was used as a technique to detect radiation-induced DNA breakage with special emphasis to biological relevant X-ray doses (0-10 Gy). Fluorescence detection of DNA-fragments using a sensitive image analysis system was directly compared with conventional scintillation counting of

  11. Performing Isoelectric Focusing and Simultaneous Fractionation of Proteins on A Rotary Valve Followed by Sodium Dodecyl – Polyacrylamide Gel Electrophoresis

    Science.gov (United States)

    Wang, Wei; Lu, Joann J.; Gu, Congying; Zhou, Lei; Liu, Shaorong

    2013-01-01

    In this technical note, we design and fabricate a novel rotary valve and demonstrate its feasibility for performing isoelectric focusing and simultaneous fractionation of proteins, followed by sodium dodecyl – polyacrylamide gel electrophoresis. The valve has two positions. In one position, the valve routes a series of capillary loops together into a single capillary tube where capillary isoelectric focusing (CIEF) is performed. By switching the valve to another position, the CIEF-resolved proteins in all capillary loops are isolated simultaneously, and samples in the loops are removed and collected in vials. After the collected samples are briefly processed, they are separated via sodium dodecyl – polyacrylamide gel electrophoresis (SDS-PAGE, the 2nd-D separation) on either a capillary gel electrophoresis instrument or a slab-gel system. The detailed valve configuration is illustrated, and the experimental conditions and operation protocols are discussed. PMID:23819755

  12. Investigation on accordance of DNA double-strand break of blood between in vivo and in vitro irradiation using single cell gel electrophoresis

    International Nuclear Information System (INIS)

    Liu Qiang; Jiang Enhai; Li Jin; Tang Weisheng; Wang Zhiquan; Zhao Yongcheng; Fan Feiyue

    2006-01-01

    Objective: To observe the consistency of DNA double-strand break between in vivo and in vitro irradiation, as a prophase study in radiation biodosimetry using single cell gel electrophoresis (SCGE). Methods: Detect DNA double-strand break after whole-body and in vitro radiation in mice lymphocytes using neutral single cell gel electrophoresis. The comet images were processed by CASP software and all the data were analysed by SPSS12.0. Results: There is no difference between in vivo and in vitro irradiation group in HDNA%, TDNA%, CL, TL, TM and OTM. Conclusion: The result of neutral single cell gel electrophoresis shortly after in vitro irradiation can precisely reflect the DNA double-strand break of lymphocytes in whole-body irradiation. (authors)

  13. Two-dimensional capillary electrophoresis: capillary isoelectric focusing and capillary zone electrophoresis with laser-induced fluorescence detection

    Science.gov (United States)

    Dickerson, Jane A.; Ramsay, Lauren M.; Dada, Oluwatosin O.; Cermak, Nathan

    2011-01-01

    Capillary isoelectric focusing and capillary zone electrophoresis are coupled with laser-induced fluorescence detection to create an ultrasensitive two-dimensional separation method for proteins. In this method, two capillaries are joined through a buffer filled interface. Separate power supplies control the potential at the injection end of the first capillary and at the interface; the detector is held at ground potential. Proteins are labeled with the fluorogenic reagent Chromeo P503, which preserves the isoelectric point of the labeled protein. The labeled proteins were mixed with ampholytes and injected into the first dimension capillary. A focusing step was performed with the injection end of the capillary at high pH and the interface at low pH. To mobilize components, the interface was filled with a high pH buffer, which was compatible with the second dimension separation. A fraction was transferred to the second dimension capillary for separation. The process of fraction transfer and second dimension separation was repeated two dozen times. The separation produced a spot capacity of 125. PMID:20603830

  14. Analysis of arecoline in Semen Arecae decoction pieces by microchip capillary electrophoresis with contactless conductivity detection

    Directory of Open Access Journals (Sweden)

    Zi-You Cai

    2012-10-01

    Full Text Available A new method for the determination of arecoline in Semen Arecae decoction pieces by microchip capillary electrophoresis with contactless conductivity detection (MCE-CCD was proposed. The effects of various electrophoretic operating parameters on the analysis of arecoline were studied. Under the optimal conditions, arecoline was rapidly separated and detected in 1 min with good linearity over the concentration range of 20–1500 μM (r2=0.9991 and the detection limit of 5 μM (S/N=3. The method was used for the analysis of arecoline satisfactorily with a recovery of 96.8–104%. Keywords: Microchip capillary electrophoresis, Contactless conductivity detection, Arecoline, Semen Arecae

  15. Melanie II--a third-generation software package for analysis of two-dimensional electrophoresis images: II. Algorithms.

    Science.gov (United States)

    Appel, R D; Vargas, J R; Palagi, P M; Walther, D; Hochstrasser, D F

    1997-12-01

    After two generations of software systems for the analysis of two-dimensional electrophoresis (2-DE) images, a third generation of such software packages has recently emerged that combines state-of-the-art graphical user interfaces with comprehensive spot data analysis capabilities. A key characteristic common to most of these software packages is that many of their tools are implementations of algorithms that resulted from research areas such as image processing, vision, artificial intelligence or machine learning. This article presents the main algorithms implemented in the Melanie II 2-D PAGE software package. The applications of these algorithms, embodied as the feature of the program, are explained in an accompanying article (R. D. Appel et al.; Electrophoresis 1997, 18, 2724-2734).

  16. [Elective abortions, a right to defend].

    Science.gov (United States)

    Zaccabri, Annie

    2015-12-01

    Every year in France, almost 210 000 women request a termination of an unwanted pregnancy. Two thirds of them were however using a form of contraception, hence the importance, for caregivers, of encouraging women to find the method which works best for them. The right to abortion is the fruit of a long fight for a woman's right to control her own body. It is a right which must be protected. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  17. Identification of DNA-binding proteins that interact with the 5'-flanking region of the human D-amino acid oxidase gene by pull-down assay coupled with two-dimensional gel electrophoresis and mass spectrometry.

    Science.gov (United States)

    Tran, Diem Hong; Shishido, Yuji; Chung, Seong Pil; Trinh, Huong Thi Thanh; Yorita, Kazuko; Sakai, Takashi; Fukui, Kiyoshi

    2015-12-10

    D-Amino acid oxidase (DAO) is a flavoenzyme that metabolizes D-amino acids and is expected to be a promising therapeutic target of schizophrenia and glioblastoma. The study of DNA-binding proteins has yielded much information in the regulation of transcription and other biological processes. However, proteins interacting with DAO gene have not been elucidated. Our assessment of human DAO promoter activity using luciferase reporter system indicated the 5'-flanking region of this gene (-4289 bp from transcription initiation site) has a regulatory sequence for gene expression, which is regulated by multi-protein complexes interacting with this region. By using pull-down assay coupled with two-dimensional gel electrophoresis and mass spectrometry, we identified six proteins binding to the 5'-flanking region of the human DAO gene (zinc finger C2HC domain-containing protein 1A; histidine-tRNA ligase, cytoplasmic; molybdenum cofactor biosynthesis protein; 60S ribosomal protein L37; calponin-1; calmodulin binding protein and heterogeneous nuclear ribonucleoprotein A2/B1). These preliminary results will contribute to the advance in the understanding of the potential factors associated with the regulatory mechanism of DAO expression. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Free flow electrophoresis separation and AMS quantitation of 14C-naphthalene-protein adducts

    International Nuclear Information System (INIS)

    Buchholz, Bruce A.; Haack, Kurt W.; Sporty, Jennifer L.; Buckpitt, Alan R.; Morin, Dexter

    2010-01-01

    Naphthalene is a volatile aromatic hydrocarbon to which humans are exposed from a variety of sources including mobile air sources and cigarette smoke. Naphthalene produces dose-(concentration)dependent injury to airway epithelial cells of murine lung which is observed at concentrations well below the current occupational exposure standard. Toxicity is dependent upon the cytochrome P450 mediated metabolic activation of the parent substrate to unstable metabolites which become bound covalently to tissue proteins. Nearly 70 proteins have been identified as forming adducts with reactive naphthalene metabolites using in vitro systems but very little work has been conducted in vivo because reasonably large amounts (100 μCi) of 14 C labeled parent compound must be administered to generate detectable adduct levels on storage phosphor screens following separation of labeled proteins by 2D gel electrophoresis. The work described here was done to provide proof of concept that protein separation by free flow electrophoresis followed by AMS detection of protein fractions containing protein bound reactive metabolites would provide adducted protein profiles in animals dosed with trace quantities of labeled naphthalene. Mice were administered 200 mg/kg naphthalene intraperitoneally at a calculated specific activity of 2 DPM/nmol (1 pCi/nmol) and respiratory epithelial tissue was obtained by lysis lavage 4 h post injection. Free flow electrophoresis (FFE) separates proteins in the liquid phase over a large pH range (2.5-11.5) using low molecular weight acids and bases to modify the pH. The apparatus separates fractions into standard 96-well plates that can be used in other protein analysis techniques. The buffers of the fractions have very high carbon content, however, and need to be dialyzed to yield buffers compatible with 14 C-AMS. We describe the processing techniques required to couple FFE to AMS for quantitation of protein adducts.

  19. Free flow electrophoresis separation and AMS quantitation of 14C-naphthalene-protein adducts

    Science.gov (United States)

    Buchholz, Bruce A.; Haack, Kurt W.; Sporty, Jennifer L.; Buckpitt, Alan R.; Morin, Dexter

    2010-04-01

    Naphthalene is a volatile aromatic hydrocarbon to which humans are exposed from a variety of sources including mobile air sources and cigarette smoke. Naphthalene produces dose-(concentration)dependent injury to airway epithelial cells of murine lung which is observed at concentrations well below the current occupational exposure standard. Toxicity is dependent upon the cytochrome P450 mediated metabolic activation of the parent substrate to unstable metabolites which become bound covalently to tissue proteins. Nearly 70 proteins have been identified as forming adducts with reactive naphthalene metabolites using in vitro systems but very little work has been conducted in vivo because reasonably large amounts (100 μCi) of 14C labeled parent compound must be administered to generate detectable adduct levels on storage phosphor screens following separation of labeled proteins by 2D gel electrophoresis. The work described here was done to provide proof of concept that protein separation by free flow electrophoresis followed by AMS detection of protein fractions containing protein bound reactive metabolites would provide adducted protein profiles in animals dosed with trace quantities of labeled naphthalene. Mice were administered 200 mg/kg naphthalene intraperitoneally at a calculated specific activity of 2 DPM/nmol (1 pCi/nmol) and respiratory epithelial tissue was obtained by lysis lavage 4 h post injection. Free flow electrophoresis (FFE) separates proteins in the liquid phase over a large pH range (2.5-11.5) using low molecular weight acids and bases to modify the pH. The apparatus separates fractions into standard 96-well plates that can be used in other protein analysis techniques. The buffers of the fractions have very high carbon content, however, and need to be dialyzed to yield buffers compatible with 14C-AMS. We describe the processing techniques required to couple FFE to AMS for quantitation of protein adducts.

  20. Capillary Electrophoresis Sensitivity Enhancement Based on Adaptive Moving Average Method.

    Science.gov (United States)

    Drevinskas, Tomas; Telksnys, Laimutis; Maruška, Audrius; Gorbatsova, Jelena; Kaljurand, Mihkel

    2018-06-05

    In the present work, we demonstrate a novel approach to improve the sensitivity of the "out of lab" portable capillary electrophoretic measurements. Nowadays, many signal enhancement methods are (i) underused (nonoptimal), (ii) overused (distorts the data), or (iii) inapplicable in field-portable instrumentation because of a lack of computational power. The described innovative migration velocity-adaptive moving average method uses an optimal averaging window size and can be easily implemented with a microcontroller. The contactless conductivity detection was used as a model for the development of a signal processing method and the demonstration of its impact on the sensitivity. The frequency characteristics of the recorded electropherograms and peaks were clarified. Higher electrophoretic mobility analytes exhibit higher-frequency peaks, whereas lower electrophoretic mobility analytes exhibit lower-frequency peaks. On the basis of the obtained data, a migration velocity-adaptive moving average algorithm was created, adapted, and programmed into capillary electrophoresis data-processing software. Employing the developed algorithm, each data point is processed depending on a certain migration time of the analyte. Because of the implemented migration velocity-adaptive moving average method, the signal-to-noise ratio improved up to 11 times for sampling frequency of 4.6 Hz and up to 22 times for sampling frequency of 25 Hz. This paper could potentially be used as a methodological guideline for the development of new smoothing algorithms that require adaptive conditions in capillary electrophoresis and other separation methods.

  1. Deposition of Pd Nanoparticles on InP by Electrophoresis: Dependence on Electrode Polarity

    Czech Academy of Sciences Publication Activity Database

    Žďánský, Karel; Zavadil, Jiří; Lorinčík, Jan; Kacerovský, Pavel; Fojtík, A.

    2010-01-01

    Roč. 9, č. 3 (2010), s. 355-360 ISSN 1536-125X R&D Projects: GA AV ČR(CZ) KAN401220801; GA AV ČR KAN400670651 Institutional research plan: CEZ:AV0Z20670512 Keywords : Electrophoresis * nanoparticles * Schottky barrier Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.864, year: 2010

  2. Enhanced detergent extraction for analysis of membrane proteomes by two-dimensional gel electrophoresis

    Directory of Open Access Journals (Sweden)

    Hsu Kimberly K

    2005-06-01

    Full Text Available Abstract Background The analysis of hydrophobic membrane proteins by two-dimensional gel electrophoresis has long been hampered by the concept of inherent difficulty due to solubility issues. We have optimized extraction protocols by varying the detergent composition of the solubilization buffer with a variety of commercially available non-ionic and zwitterionic detergents and detergent-like phospholipids. Results After initial analyses by one-dimensional SDS-PAGE, quantitative two-dimensional analyses of human erythrocyte membranes, mouse liver membranes, and mouse brain membranes, extracted with buffers that included the zwitterionic detergent MEGA 10 (decanoyl-N-methylglucamide and the zwitterionic lipid LPC (1-lauroyl lysophosphatidylcholine, showed selective improvement over extraction with the common 2-DE detergent CHAPS (3 [(3-cholamidopropyldimethylammonio]-1-propanesulfonate. Mixtures of the three detergents showed additive improvements in spot number, density, and resolution. Substantial improvements in the analysis of a brain membrane proteome were observed. Conclusion This study demonstrates that an optimized detergent mix, coupled with rigorous sample handling and electrophoretic protocols, enables simple and effective analysis of membrane proteomes using two-dimensional electrophoresis.

  3. Ultrafast Capillary Electrophoresis Isolation of DNA Aptamer for the PCR Amplification-Based Small Analyte Sensing

    Directory of Open Access Journals (Sweden)

    Emmanuelle eFiore

    2015-08-01

    Full Text Available Here, we report a new homogeneous DNA amplification-based aptamer assay for small analyte sensing. The aptamer of adenosine chosen as the model analyte was split into two fragments able to assemble in the presence of target. Primers were introduced at extremities of one fragment in order to generate the amplifiable DNA component. The amount of amplifiable fragment was quantifiable by Real-Time Polymerase Chain Reaction (RT-PCR amplification and directly reliable on adenosine concentration. This approach combines the very high separation efficiency and the homogeneous format (without immobilization of capillary electrophoresis and the sensitivity of real time PCR amplification. An ultrafast isolation of target-bound split aptamer (60 s was developed by designing a capillary electrophoresis input/ouput scheme. Such method was successfully applied to the determination of adenosine with a LOD of 1 µM.

  4. Determination of anions with an on-line capillary electrophoresis method; Anionien on-line maeaeritys kapillaarielektroforeesilla - MPKT 10

    Energy Technology Data Exchange (ETDEWEB)

    Siren, H.; Saerme, T.; Kotiaho, T.; Hiissa, T.; Savolahti, P.; Komppa, V. [VTT Chemical Technology, Espoo (Finland)

    1998-12-31

    The aim of the study was to set-up an on-line capillary electrophoresis method for determination of anions in process waters of pulp and paper industry with exporting the results to the process control system of the mill. The quantification is important, since it will give information about the possible causes of precipitation. In recent years, the capillary electrophoresis (CE) due to its high separation efficiency has been shown as a method to take into consideration when analyzing chemical species ranging from small inorganic anions to different macromolecules. Many compounds are not easily detected in their native state, why analysis methods must be developed to improve their detection. Especially, small inorganic and organic anions which do not have chromophores are not sensitive enough for direct-UV detection. In such analyses the anions are mostly detected with indirect-UV technique. Capillary electrophoresis instruments are used to analyze samples in off-line, which seldom represent the situation in process. Therefore, on-line instrument technology with autoanalyzing settings will be needed in quality control. The development of a fully automatic capillary electrophoresis system is underway in co-operation with KCL (The Finnish Pulp and Paper Research Institute). In our research, we have first concentrated on the determination of sulphate in waters of paper industry. The method used for detection of sulphate is based on indirect-UV detection with CE, where the background electrolyte (BGE) is an absorbing mixture of secondary amines. The whole procedure for quantification of sulphate is performed within 15 minutes, after which a new sample is analyzed automatically. The only sample pretreatment is filtration, which is necessary before analysis. The concentrations of sulphate in process waters tested were between 300 and 800 ppm. Our tests show that a simultaneous determination of chloride, sulphate, nitrate, nitrite, sulphite, carbonate and oxalate is also

  5. Determination of anions with an on-line capillary electrophoresis method; Anionien on-line maeaeritys kapillaarielektroforeesilla - MPKT 10

    Energy Technology Data Exchange (ETDEWEB)

    Siren, H; Saerme, T; Kotiaho, T; Hiissa, T; Savolahti, P; Komppa, V [VTT Chemical Technology, Espoo (Finland)

    1999-12-31

    The aim of the study was to set-up an on-line capillary electrophoresis method for determination of anions in process waters of pulp and paper industry with exporting the results to the process control system of the mill. The quantification is important, since it will give information about the possible causes of precipitation. In recent years, the capillary electrophoresis (CE) due to its high separation efficiency has been shown as a method to take into consideration when analyzing chemical species ranging from small inorganic anions to different macromolecules. Many compounds are not easily detected in their native state, why analysis methods must be developed to improve their detection. Especially, small inorganic and organic anions which do not have chromophores are not sensitive enough for direct-UV detection. In such analyses the anions are mostly detected with indirect-UV technique. Capillary electrophoresis instruments are used to analyze samples in off-line, which seldom represent the situation in process. Therefore, on-line instrument technology with autoanalyzing settings will be needed in quality control. The development of a fully automatic capillary electrophoresis system is underway in co-operation with KCL (The Finnish Pulp and Paper Research Institute). In our research, we have first concentrated on the determination of sulphate in waters of paper industry. The method used for detection of sulphate is based on indirect-UV detection with CE, where the background electrolyte (BGE) is an absorbing mixture of secondary amines. The whole procedure for quantification of sulphate is performed within 15 minutes, after which a new sample is analyzed automatically. The only sample pretreatment is filtration, which is necessary before analysis. The concentrations of sulphate in process waters tested were between 300 and 800 ppm. Our tests show that a simultaneous determination of chloride, sulphate, nitrate, nitrite, sulphite, carbonate and oxalate is also

  6. Amplified fragment length polymorphism and pulsed field gel electrophoresis for subspecies differentiation of Serpulina pilosicoli

    DEFF Research Database (Denmark)

    Møller, Kristian; Jensen, Tim Kåre; Boye, Mette

    1999-01-01

    Pulsed field gel electrophoresis (PFGE) and amplified fragment length polymorphism (AFLP) were compared for their ability to differentiate between 50 porcine Serpulina pilosicoli isolates. Both techniques were highly sensitive, dividing the isolates into 36 and 38 groups, respectively. Due...

  7. INFLUENCE OF BORATE BUFFERS ON THE ELECTROPHORETIC BEHAVIOR OF HUMIC SUBSTANCES IN CAPILLARY ZONE ELECTROPHORESIS

    Science.gov (United States)

    The influence of tetrahydroxyborate ions on the electrophoretic mobility of humic acids was evaluated by capillary electrophoresis (CE). Depending on the molarity of borate ions in the separation buffer, the humic acids exhibit electropherograms with sharp peaks consistently exte...

  8. [The efficacy of the combined use of 5-fluorouracil electrophoresis and magnetotherapy in experimental pancreatitis].

    Science.gov (United States)

    Kents, V V; Tsympilova, T A; Mavrodiĭ, V M; Godlevskiĭ, L S

    1994-01-01

    As shown on the experimental model of rat acute pancreatitis, an intensive 5-fluorouracil electrophoresis course in combination with magnetotherapy significantly reduces the activity of blood trypsin, amylase, lipase and corticosterone. The treatment is thought effective in experimental pancreatitis.

  9. Separation and quantification of cellulases and hemicellulases by capillary electrophoresis

    DEFF Research Database (Denmark)

    Jørgensen, Henning; Kutter, Jörg Peter; Olsson, Lisbeth

    2003-01-01

    Cellulases and hemicellulases are two classes of enzymes produced by filamentous fungi and secreted into the cultivation medium. Both classes of enzymes consist of a subset of classes of which the fungi produce several enzymes with varying molecular mass and pI but similar enzymatic activities....... Current methods are limited in their ability to quantify all of these enzymes when all are present simultaneously in a mixture. Five different cellulases (two cellobiohydrolases and three endoglucanases) and one hemicellulase (endoxylanase) were separated using capillary electrophoresis (CE) in a fused...

  10. [The reasonable use of right ventricular protection strategy in right ventricular outflow tract reconstruction].

    Science.gov (United States)

    Zhang, Y; Yuan, H Y; Liu, X B; Wen, S S; Xu, G; Cui, H J; Zhuang, J; Chen, J M

    2018-06-01

    As a result of right ventricular outflow tract reconstruction, which is the important and basic step of complex cardiac surgery, the blood flow of right ventricular outflow tract is unobstructed, while pulmonary valve regurgitation and right heart dysfunction could be happened. These problems are often ignored in early days, more and more cases of right heart dysfunction need clinical intervention, which is quite difficult and less effective. How to protect effectively the right ventricular function is the focus. At present main methods to protect the right ventricular function include trying to avoid or reduce length of right ventricular incision, reserving or rebuilding the function of the pulmonary valve, using growth potential material for surgery. The protection of the right ventricular function is a systemic project, it involves many aspects, single measures is difficult to provide complete protection, only the comprehensive use of various protection strategy, can help to improve the long-term prognosis.

  11. Determination of monosaccharides derivatized with 2-aminobenzoic Acid by capillary electrophoresis.

    Science.gov (United States)

    Abo, Mitsuru; He, Li-Ping; Sato, Kae; Okubo, Akira

    2013-01-01

    Reducing monosaccharides were derivatized with 2-aminobenzoic acid (2-AA) through reductive amination using sodium cyanoborohydride as a reductant, and the derivatives were separated by capillary zone electrophoresis with UV detection using 50 mM sodium phosphate (pH 5.5) or 150 mM sodium borate-50 mM sodium phosphate (pH 7.0) running buffer. The derivatives of monosaccharides, which are major components of various carbohydrate materials, were completely separated within 25 min.

  12. Chiral analysis of acyclic nucleoside phosphonates-based anti-aids drugs by capillary electrophoresis

    Czech Academy of Sciences Publication Activity Database

    Kašička, Václav; Šolínová, Veronika; Sázelová, Petra; Mikysková, Hana; Jansa, Petr; Krečmerová, Marcela; Holý, Antonín

    2012-01-01

    Roč. 106, - (2012), s604-s604 ISSN 0009-2770. [EuCheMS Chemistry Congress /4./. 26.08.2012-30.08.2012, Prague] R&D Projects: GA MŠk 1M0508; GA ČR(CZ) GA203/08/1428 Institutional research plan: CEZ:AV0Z40550506 Keywords : analytical methods * electrophoresis * enentioselectivity Subject RIV: CC - Organic Chemistry

  13. Determination of acid dissociation constants of triazole fungicides by pressure assisted capillary electrophoresis

    Czech Academy of Sciences Publication Activity Database

    Konášová, Renáta; Jaklová Dytrtová, Jana; Kašička, Václav

    2015-01-01

    Roč. 1408, Aug 21 (2015), s. 243-249 ISSN 0021-9673 R&D Projects: GA ČR(CZ) GA13-17224S; GA ČR GP13-21409P Institutional support: RVO:61388963 Keywords : triazole fungicides * acid dissociation constant * pK(a) * capillary electrophoresis * ionic mobility Subject RIV: CB - Analytical Chemistry , Separation Impact factor: 3.926, year: 2015

  14. Purification of Peptide Components including Melittin from Bee Venom using gel filtration chromatography and propionic acid/urea polyacrylamide gel electrophoresis

    Directory of Open Access Journals (Sweden)

    Young Chon Choi

    2006-06-01

    Full Text Available Objectives : This study was conducted to carry out Purification of Melittin and other peptide components from Bee Venom using gel filtration chromatography and propionic acid/urea polyacrylamide gel electrophoresis Methods : Melittin and other peptide components were separated from bee venom by using gel filtration chromatography on Sephadex G-50 column in 0.05M ammonium acetate buffer. Results : Melittin and other peptide components were separated from bee venom by using gel filtration chromatography on Sephadex G-50 column in 0.05M ammonium acetate buffer. The fractions obtained from gel filtration chromatography was analyzed by using SDS-PAGE and propionic acid/urea polyacrylamide gel electrophoresis. The melittin obtained from the gel filtration contained residual amount of phospholipase A2 and a protein with molecular weight of 6,000. The contaminating proteins were removed by the second gel filtration chromatography. Conclusion : Gel filtration chromatography and propionic acid/urea polyacrylamide gel electrophoresis are useful to separate peptide components including melittin from bee venom.

  15. High-throughput determination of urinary hexosamines for diagnosis of mucopolysaccharidoses by capillary electrophoresis and high-performance liquid chromatography.

    Science.gov (United States)

    Coppa, Giovanni V; Galeotti, Fabio; Zampini, Lucia; Maccari, Francesca; Galeazzi, Tiziana; Padelia, Lucia; Santoro, Lucia; Gabrielli, Orazio; Volpi, Nicola

    2011-04-01

    , diagnosis, and their treatment. Copyright © 2010 Elsevier Inc. All rights reserved.

  16. Detection of hydrolysis of lipid post-translational modifications during gel-electrophoresis-based proteomic protocol

    Czech Academy of Sciences Publication Activity Database

    Žídková, Jitka; Řehulka, Pavel; Chmelík, Josef

    2007-01-01

    Roč. 7, č. 15 (2007), s. 2507-2510 ISSN 1615-9853 R&D Projects: GA MŠk 1M0570 Institutional research plan: CEZ:AV0Z40310501 Keywords : ester hydrolysis * gel electrophoresis * MALDI-TOF MS Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 5.479, year: 2007

  17. System zones in capillary zone electrophoresis: Moving boundaries caused by freely migrating hydroxide ions

    Czech Academy of Sciences Publication Activity Database

    Beckers, J. L.; Urbánek, Marek; Boček, Petr

    2005-01-01

    Roč. 26, č. 10 (2005), s. 1869-1873 ISSN 0173-0835 R&D Projects: GA AV ČR IAA4031103 Institutional research plan: CEZ:AV0Z40310501 Keywords : background electrolyte * capillary electrophoresis * system zone s Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.850, year: 2005

  18. Application of capillary electrophoresis to the simultaneous determination and stability study of four extensively used penicillin derivatives

    Directory of Open Access Journals (Sweden)

    Brigitta Simon

    2014-09-01

    Full Text Available The applicability of capillary electrophoresis for the analysis of four extensively used penicillin derivatives (benzylpenicillin, ampicillin, amoxicillin, oxacilllin has been studied. Because of structural similarities, the electrophoretic behavior of these derivatives is very similar; consequently an efficient separation using the conventional capillary zone electrophoresis is hard to be achieved. Their simultaneous separation was solved by using micellar electrokinetic capillary chromatography, the separation being based on the differential partition of the analytes between the micellar and aqueous phase. Using a buffer solution containing 25 mM sodium tetraborate and 100 mM sodium dodecyl sulfate as surfactant, at a pH of 9.3, applying a voltage of + 25 kV at a temperature of 25 °C, we achieved the simultaneous separation of the studied penicillin derivatives in less then 5 minutes. The separation conditions were optimized and the analytical performance of the method was evaluated in terms of precision, linearity, limit of detection, and quantification. Also, a simple capillary zone electrophoresis method was applied to study the stability of the studied penicillin derivatives in water at different temperatures, using ciprofloxacin hydrochloride as internal standard. It was observed that the extent of the hydrolysis of penicillins in water is highly dependent on the time and also temperature.

  19. Integration of Microchip Electrophoresis with Electrochemical Detection Using an Epoxy-Based Molding Method to Embed Multiple Electrode Materials

    Science.gov (United States)

    Johnson, Alicia S.; Selimovic, Asmira; Martin, R. Scott

    2012-01-01

    This paper describes the use of epoxy-encapsulated electrodes to integrate microchip-based electrophoresis with electrochemical detection. Devices with various electrode combinations can easily be developed. This includes a palladium decoupler with a downstream working electrode material of either gold, mercury/gold, platinum, glassy carbon, or a carbon fiber bundle. Additional device components such as the platinum wires for the electrophoresis separation and the counter electrode for detection can also be integrated into the epoxy base. The effect of the decoupler configuration was studied in terms of the separation performance, detector noise, and the ability to analyze samples of a high ionic strength. The ability of both glassy carbon and carbon fiber bundle electrodes to analyze a complex mixture was demonstrated. It was also shown that a PDMS-based valving microchip can be used along with the epoxy embedded electrodes to integrate microdialysis sampling with microchip electrophoresis and electrochemical detection, with the microdialysis tubing also being embedded in the epoxy substrate. This approach enables one to vary the detection electrode material as desired in a manner where the electrodes can be polished and modified in a similar fashion to electrochemical flow cells used in liquid chromatography. PMID:22038707

  20. An accessible micro-capillary electrophoresis device using surface-tension-driven flow

    Science.gov (United States)

    Mohanty, Swomitra K.; Warrick, Jay; Gorski, Jack; Beebe, David J.

    2010-01-01

    We present a rapidly fabricated micro-capillary electrophoresis chip that utilizes surface-tension-driven flow for sample injection and extraction of DNA. Surface-tension-driven flow (i.e. passive pumping) injects a fixed volume of sample that can be predicted mathematically. Passive pumping eliminates the need for tubing, valves, syringe pumps, and other equipment typically needed for interfacing with microelectrophoresis chips. This method requires a standard micropipette to load samples before separation, and remove the resulting bands after analysis. The device was made using liquid phase photopolymerization to rapidly fabricate the chip without the need of special equipment typically associated with the construction of microelectrophoresis chips (e.g. cleanroom). Batch fabrication time for the device presented here was 1.5 h including channel coating time to suppress electroosmotic flow. Devices were constructed out of poly-isobornyl acrylate and glass. A standard microscope with a UV source was used for sample detection. Separations were demonstrated using Promega BenchTop 100 bp ladder in hydroxyl ethyl cellulose (HEC) and oligonucleotides of 91 and 118 bp were used to characterize sample injection and extraction of DNA bands. The end result was an inexpensive micro-capillary electrophoresis device that uses tools (e.g. micropipette, electrophoretic power supplies, and microscopes) already present in most labs for sample manipulation and detection, making it more accessible for potential end users. PMID:19425002

  1. Leaf Protein Electrophoresis and Taxonomy of Species of Jatropha L. (Euphorbiaceae

    Directory of Open Access Journals (Sweden)

    Olaniran Temitope OLADIPO

    2012-08-01

    Full Text Available The systematic relationship existing among members of the all important genus Jatropha was studied using leaf protein electrophoresis. The aim was to identify possible taxonomic importance of the protein profile in the estimation and elucidation of the taxonomic affinity of the six species of Jatropha (Jatropha curcas Linn., J. podagrica Hook., J. gossypifolia Linn., J. mutifida Linn., J. tanjorensis Ellis & Saroja and J. integerrima Linn. found in Nigeria. The species were screened for total protein banding patterns using gel electrophoresis. Young leaves (0.8 g of the plants were washed with distilled water and macerated with sterile mortar and pestle in 0.8% Phosphate Buffer-Saline (PBS containing 0.4 M NaCl at pH 8.0. Results reveal that protein banding pattern was taxon specific. Generic band occurs at 8.3. The highest number of interspecific bands (4 exists between J. podagrica and J. multifida. Variations exist not only in the number of bands but also in the intensity of the bands. Sokal and Sneath coefficient of similarity ranges between 11.1-44.4 %. Single linkage Cluster Analysis (SLCA of the relative mobility values of the protein in the taxa shows partial agreement with current sub generic and sectional delimitation of the species based on morphology and anatomy of the species.

  2. Impact of quenching failure of Cy dyes in differential gel electrophoresis.

    Directory of Open Access Journals (Sweden)

    Weiqun Wang

    Full Text Available BACKGROUND: Differential gel electrophoresis (DIGE is a technology widely used for protein expression analysis. It is based on labelling with fluorescent Cy dyes. In comparative fluorescence gel electrophoresis experiments, however, unspecific labelling using N-hydroxy-succinimide-ester-based labelling protocols was recently detected. Cross-talk was observed due to failure of the quenching process. Here, the impact of this effect for DIGE experiments was investigated. METHODOLOGY/PRINCIPAL FINDINGS: Experiments to test quenching efficiency were performed in replicate using Escherichia coli lysate. Parameters such as the amount of dye and quencher were varied. Labelling and quenching were reversed in one experiment. Differences in protein spot volumes due to limited quenching were determined. For some spots twice the volume was detected underscoring the importance of proper control of silencing of active dye. CONCLUSIONS/SIGNIFICANCE: It could be demonstrated that uncontrolled labelling increased protein spot volume, even doubling it in some cases. Moreover, proteins responded differently to the protocol. Such unpredictable and unspecific processes are not acceptable in protein regulation studies so that it is necessary to validate the correct amount of quencher for individual samples before the DIGE experiment is performed. Increase of the concentration of lysine, which is used as quencher, from 10 mM to 2500 mM, was sufficient to silence the dye. Alternatively, active dye molecules can be removed by filtration.

  3. Determination of acid-base dissociation constants of azahelicenes by capillary zone electrophoresis

    Czech Academy of Sciences Publication Activity Database

    Ehala, Sille; Míšek, Jiří; Stará, Irena G.; Starý, Ivo; Kašička, Václav

    2008-01-01

    Roč. 31, č. 14 (2008), s. 2686-2693 ISSN 1615-9306 R&D Projects: GA ČR(CZ) GA203/06/1044; GA ČR GA203/08/1428; GA ČR GA203/07/1664; GA MŠk LC512 Institutional research plan: CEZ:AV0Z40550506 Keywords : acidity constant * azahelicenes * non-aqueous capillary electrophoresis Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 2.746, year: 2008

  4. A Novel Protocol to Analyze Short- and Long-Chain Fatty Acids Using Nonaqueous Microchip Capillary Electrophoresis

    Science.gov (United States)

    Cable, M. L.; Stockton, A. M.; Mora, Maria F; Willis, P. A.

    2013-01-01

    We propose a new protocol to identify and quantify both short- and long-chain saturated fatty acids in samples of astrobiological interest using non-aqueous microchip capillary electrophoresis (micronNACE) with laser induced fluorescence (LIF).

  5. Identification and characterization of a thermally cleaved fragment of monoclonal antibody-A detected by sodium dodecyl sulfate-capillary gel electrophoresis.

    Science.gov (United States)

    Kubota, Kei; Kobayashi, Naoki; Yabuta, Masayuki; Ohara, Motomu; Naito, Toyohiro; Kubo, Takuya; Otsuka, Koji

    2017-06-05

    This report describes a novel, comprehensive approach to identifying a fragment peak of monoclonal antibody-A (mAb-A), detected by sodium dodecyl sulfate-capillary gel electrophoresis (SDS-cGE). The fragment migrated close to the internal standard (10kDa marker) of SDS-cGE and increased about 0.5% under a 25°C condition for 6 months. Generally, identification of fragments observed in SDS-cGE is challenging to carry out due to the difficulty of collecting analytical amounts of fractionations from the capillary. In this study, in-gel digestion peptide mapping and reversed phase liquid chromatography-mass spectrometry (RPLC-MS) were employed to elucidate the structure of the fragment. In addition, a Gelfree 8100 fractionation system was newly introduced to collect the fragment and the fraction was applied to the structural analysis of a mAb for the first time. These three analytical methods showed comparable results, proving that the fragment was a fraction of heavy chain HC1-104. The fragment contained complementarity determining regions (CDRs), which are significant to antigen binding, and thus would affect the efficacy of mAb-A. In addition, SDS-cGE without the 10kDa marker was demonstrated to clarify the increased amount of the fragment, and the experiment revealed that the fragment increases 0.2% per year in storage at 5°C. The combination of the three analytical methodologies successfully identified the impurity peak detected by SDS-cGE, providing information critical to assuring the quality and stability of the biotherapeutics. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Comparison of Pseudomonas aeruginosa isolates from mink by serotyping and pulsed-field gel electrophoresis

    DEFF Research Database (Denmark)

    Hammer, Anne Sofie; Pedersen, Karl; Andersen, Thomas Holmen

    2003-01-01

    Isolates of Pseudomonas aeruginosa from clinical infections in mink were subjected to serotyping and pulsed-field gel electrophoresis (PFGE) using SpeI. A total of 212 isolates of P aeruginosa from the year 1998 to 2001 were included in this study: 168 isolates from mink obtained from 74 farm out...

  7. Estimation of acidity constants, ionic mobilities and charges of antimicrobial peptides by capillary electrophoresis

    Czech Academy of Sciences Publication Activity Database

    Tůmová, Tereza; Monincová, Lenka; Čeřovský, Václav; Kašička, Václav

    2016-01-01

    Roč. 37, 23/24 (2016), s. 3186-3195 ISSN 0173-0835 R&D Projects: GA ČR(CZ) GA15-01948S Institutional support: RVO:61388963 Keywords : acid dissociation constant * antimicrobial peptides * capillary electrophoresis * charge * mobility * Pka Subject RIV: CB - Analytical Chemistry , Separation Impact factor: 2.744, year: 2016

  8. Detection of undeclared animal by-products in commercial canine canned foods: Comparative analyses by ELISA and PCR-RFLP coupled with slab gel electrophoresis or capillary gel electrophoresis.

    Science.gov (United States)

    Hsieh, Ming-Kun; Shih, Pei-Yin; Wei, Chia-Fong; Vickroy, Thomas W; Chou, Chi-Chung

    2016-03-30

    The potential presence of undeclared animal by-products in pet foods is not subject to routine examination. Previously published methods for species-based identification of animal by-products have not been used routinely owing to inconsistent results. The present study evaluated the utility of several approaches for accurate identification of animal by-products in 11 commercial brands of canine canned foods. Canine canned foods from several countries were analysed by ELISA, PCR-RFLP coupled with slab-gel electrophoresis (SGE) and capillary gel electrophoresis (CGE) to test for evidence of by-products derived from cattle, chicken, sheep or pig. While CGE-based analysis detected all (24) animal-derived by-products that were reported for the 11 test samples, SGE and ELISA detected only 22/24 (92%) and 14/24 (58%) of labelled by-products, respectively. In addition, undeclared animal by-products were found using all three analytical approaches with CGE detecting more positives (19) than SGE (17) or ELISA (5). Significant disparities were evident between the labelled contents and the detected content of animal by-products. CGE-based testing for PCR products appears to provide greater sensitivity and accuracy than either SGE or ELISA-based methods. As testing of commercial products becomes more reliable and mainstream, manufacturers will need to develop more thorough and accurate labelling protocols. © 2015 Society of Chemical Industry.

  9. Disappearance of endangered turtles within China's nature reserves.

    Science.gov (United States)

    Gong, Shi-Ping; Shi, Hai-Tao; Jiang, Ai-Wu; Fong, Jonathan J; Gaillard, Daniel; Wang, Ji-Chao

    2017-03-06

    China ranks first among Northern hemisphere countries for species richness, but approximately 43% of its species are threatened [1], with harvesting being the major threat to vertebrates [2]. To protect its biodiversity, China has established about 2,700 nature reserves covering 1.46 million km 2 ( about 15% of China's territory, a percentage higher than the world average [3]). With increasing habitat destruction and harvesting, nature reserves are the final refugia for threatened species. However, many Chinese nature reserves are poorly managed, leaving them vulnerable to poaching and other human encroachment [4]. In this study, we conducted a 12-year (2002-2013) case study on turtles to illustrate the damaging impacts China's nature reserves have on wildlife conservation. We discovered that poaching occurred in all of the 56 reserves surveyed, resulting in dramatically reduced turtle populations. In a majority of the reserves, the reserve staff themselves were involved in poaching. Although nature reserves were created to protect plants and animals, they have become part of the problem due to weak enforcement of rules. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. The Cutoff Level for Urine Protein in Urine Immunofixation Electrophoresis.

    Science.gov (United States)

    Ellidag, Hamit Yasar; Curek, Gulten; Eren, Esin; Aydin, Ozgur; Yilmaz, Necat

    2015-01-01

    Immunofixation electrophoresis (IFE) maintains its importance in diagnosing monoclonal gammopathies. In particular, urine IFE detects free light chains (FLC) in urine samples even at low concentrations and offers higher sensitivity compared to serum electrophoresis and serum IFE. The aim of the present study was to determine the place and significance of quantitative urinary protein measurement before IFE in interpreting the results of subsequent IFE and to determine the most appropriate protein concentrations for the appearance of bands. The records of a total of 600 patients, who underwent screening for Bence Jones proteinuria using IFE on 24-hour urine, were retrospectively reviewed. Urine IFE was performed using Helena SAS-I and SAS-I devices. The total protein concentration in the urine was quantitatively determined by the Pyrogallol red method, and the urine albumin level was determined using the immunoturbidimetric method. These analyses were measured on an Olympus/Beckmann AU5800. The evaluation of IFE results revealed that 311 patients had normal results, 108 patients had monoclonal bands, five patients had biclonal bands, 28 had polyclonal bands, and 148 patients had various degrees of proteinuria. ROC curves were created in order to determine the most appropriate urinary protein and albumin levels to observe bands in IFE. Accordingly, urine baseline protein level (mg/dL) showed the highest AUC value (cutoff value: 19.4 mg/dL, sensitivity: 92%, specificity: 98.2%, AUC: 0.972). The present study showed that quantitative protein measurement before IFE eliminated the disadvantages associated with the IFE method and its interpretation.

  11. Two-dimensional gel electrophoresis data for proteomic profiling of Sporothrix yeast cells

    Directory of Open Access Journals (Sweden)

    Anderson Messias Rodrigues

    2015-03-01

    Full Text Available Sporotrichosis is a chronic infection of the skin and subcutaneous tissues of human and other mammals caused by a complex of cryptic dimorphic fungi in the plant-associated order Ophiostomatales. With major differences between routes of transmission, Sporothrix infections are emerging as new threat in tropical and subtropical areas, particularly in form of outbreaks. The mechanisms underlying the pathogenesis and invasion of Sporothrix spp. are still poorly understood and many virulence factors remain unidentified. In this scenario, a global analysis of proteins expressed by clinical Sporothrix species combined with the identification of seroreactive proteins is overdue. Optimization of sample preparation and electrophoresis conditions are key steps toward reproducibility of gel-based proteomics assays. We provide the data generated using an efficient protocol of protein extraction for rapid and large-scale proteome analysis using two-dimensional gel electrophoresis. The protocol was established and optimized for pathogenic and non-pathogenic Sporothrix spp. including Sporothrix brasiliensis (CBS 132990, Sporothrix schenckii sensu stricto (CBS 132974, Sporothrix globosa (CBS 132922, and Sporothrix mexicana (CBS 120341. The data, supplied in this article, are related to the research article entitled “Immunoproteomic analysis reveals a convergent humoral response signature in the Sporothrix schenckii complex” (Rodrigues et al., 2014 [1].

  12. Direct measurement of lithium in whole blood using microchip capillary electrophoresis with integrated conductivity detection

    NARCIS (Netherlands)

    Vrouwe, E.X.; Lüttge, Regina; van den Berg, Albert

    2004-01-01

    The direct measurement of lithium in whole blood is described. Using microchip capillary electrophoresis (CE) with defined sample loading and applying the principles of column coupling, alkali metals were determined in a drop of whole blood. Blood collected from a finger stick was mixed with

  13. IDENTIFICATION OF DEGRADATION PRODUCTS OF SOME CHEMICAL WARFARE AGENTS BY CAPILLARY ELECTROPHORESIS IONSPRAY MASS-SPECTROMETRY

    NARCIS (Netherlands)

    KOSTIAINEN, R; BRUINS, AP; HAKKINEN, VMA

    1993-01-01

    Capillary zone electrophoresis-ionspray mass spectrometry (CZE-IS-MS) in the negative-ion mode was applied in the identification of five organophosphonic acids, which are the primary hydrolysis products of nerve agents. The spectra exhibit a very abundant (M - H)- ion with minimal fragmentation.

  14. Hair analysis for illicit drugs by using capillary zone electrophoresis-electrospray ionization-ion trap mass spektrometry

    Czech Academy of Sciences Publication Activity Database

    Gottardo, R.; Bortolotti, F.; De Paoli, G.; Pascali, J. P.; Mikšík, Ivan; Tagliaro, F.

    2007-01-01

    Roč. 1159, 1-2 (2007), s. 185-189 ISSN 0021-9673 Institutional research plan: CEZ:AV0Z50110509 Keywords : capillary electrophoresis * hair analysis Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.641, year: 2007

  15. Determination of Betaine in Jujube by Capillary Electrophoresis

    Science.gov (United States)

    Han, Likun; Liu, Haixing; Peng, Xuewei

    2017-12-01

    This paper presents the determination of betaine content in jujube by high performance capillary electrophoresis (HPCE) method. The borax solution was chosen as buffer solution, and its concentration was 40 mmol at a constant voltage of 20kV and injecting pressure time of 10s at 14°C. Linearity was kept in the concent ration range of 0.0113∼1.45mg of betaine with correlation coefficient of 0.9. The content of betaine in jujube was 85.91 mg/g (RSD = 16.6%) (n = 6). The recovery of betaine in jujube sample was in the range of 86.2% - 116.6% (n=3). This method is specific, simple and rapid and accurate, which is suitable for the detection of the content of betaine in jujube.

  16. Efficient extraction of proteins from recalcitrant plant tissue for subsequent analysis by two-dimensional gel electrophoresis.

    Science.gov (United States)

    Parkhey, Suruchi; Chandrakar, Vibhuti; Naithani, S C; Keshavkant, S

    2015-10-01

    Protein extraction for two-dimensional electrophoresis from tissues of recalcitrant species is quite problematic and challenging due to the low protein content and high abundance of contaminants. Proteomics in Shorea robusta is scarcely conducted due to the lack of a suitable protein preparation procedure. To establish an effective protein extraction protocol suitable for two-dimensional electrophoresis in Shorea robusta, four procedures (borate buffer/trichloroacetic acid extraction, organic solvent/trichloroacetic acid precipitation, sucrose/Tris/phenol, and organic solvent/phenol/sodium dodecyl sulfate) were evaluated. Following these, proteins were isolated from mature leaves and were analyzed for proteomics, and also for potential contaminants, widely reported to hinder proteomics. The borate buffer/trichloroacetic acid extraction had the lowest protein yield and did not result in any banding even in one-dimensional electrophoresis. In contrast, organic solvent/phenol/sodium dodecyl sulfate extraction allowed the highest protein yield. Moreover, during proteomics, organic solvent/phenol/sodium dodecyl sulfate extracted protein resolved the maximum number (144) of spots. Further, when proteins were evaluated for contaminants, significant (77-95%) reductions in the nucleic acids, phenol, and sugars were discernible with refinement in extraction procedure. Accumulated data suggested that the organic solvent/phenol/sodium dodecyl sulfate extraction was the most effective protocol for protein isolation for proteomics of Shorea robusta and can be used for plants that have a similar set of contaminants. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Decision peptide-driven: a free software tool for accurate protein quantification using gel electrophoresis and matrix assisted laser desorption ionization time of flight mass spectrometry.

    Science.gov (United States)

    Santos, Hugo M; Reboiro-Jato, Miguel; Glez-Peña, Daniel; Nunes-Miranda, J D; Fdez-Riverola, Florentino; Carvallo, R; Capelo, J L

    2010-09-15

    The decision peptide-driven tool implements a software application for assisting the user in a protocol for accurate protein quantification based on the following steps: (1) protein separation through gel electrophoresis; (2) in-gel protein digestion; (3) direct and inverse (18)O-labeling and (4) matrix assisted laser desorption ionization time of flight mass spectrometry, MALDI analysis. The DPD software compares the MALDI results of the direct and inverse (18)O-labeling experiments and quickly identifies those peptides with paralleled loses in different sets of a typical proteomic workflow. Those peptides are used for subsequent accurate protein quantification. The interpretation of the MALDI data from direct and inverse labeling experiments is time-consuming requiring a significant amount of time to do all comparisons manually. The DPD software shortens and simplifies the searching of the peptides that must be used for quantification from a week to just some minutes. To do so, it takes as input several MALDI spectra and aids the researcher in an automatic mode (i) to compare data from direct and inverse (18)O-labeling experiments, calculating the corresponding ratios to determine those peptides with paralleled losses throughout different sets of experiments; and (ii) allow to use those peptides as internal standards for subsequent accurate protein quantification using (18)O-labeling. In this work the DPD software is presented and explained with the quantification of protein carbonic anhydrase. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  18. Type 2 diabetes mellitus with early phase acute inflammatory protein on serum protein electrophoresis

    Directory of Open Access Journals (Sweden)

    ET Tuladhar

    2012-03-01

    Full Text Available Background: The onset of Type 2 diabetes has been associated with low grade systemic inflammation. The inflammatory status has been studied by measuring acute phase reactant proteins like hsCRP, α1- antitrypsin, α1-acid glycoprotein, ceruloplasmin, fibrinogen. Most of these acute phase reactants form α1 and α2 bands on electropherogram of serum proteins. The aim of this study was to evaluate inflammatory status in controlled and uncontrolled type 2 diabetes using cellulose acetate electrophoresis and to find the impact of glycemic status as indicated by HbA1c on inflammation process. Materials and Methods: Serum protein electrophoresis was done on serum samples of 60 cases of Diabetes [controlled and uncontrolled] using cellulose acetate paper technique. The electropherogram obtained was stained with Ponseu S and then quantitated using densitometer. Glycemic status was studied by HbA1c analysis. The density of α1and α2 bands in electropherogram were correlated with HbA1c level. Result: A significant increase in the percentage of α1 and α2 band proteins (0.765 and 0.716, p<0.001 were found with the increasing level of HbA1c. With cutoff of HbA1c 7% (American Diabetic Association recommended, the α1 and α2 serum proteins concentration are significantly higher (p<0.001 in uncontrolled diabetes mellitus compared to controlled diabetes mellitus Conclusion: Cellulose acetate electrophoresis of serum proteins show early phase acute inflammatory status in uncontrolled type 2 diabetes mellitus. The process of systemic inflammation worsens with uncontrolled glycemia as indicated by HbA1c. Inflammatory status should be studied adjunct to glycemic status. DOI: http://dx.doi.org/10.3126/jpn.v2i3.6024 JPN 2012; 2(3: 211-214

  19. The characteristics of transferrin variants by carbohydrate-deficient transferrin tests using capillary zone electrophoresis.

    Science.gov (United States)

    Yoo, Gilsung; Kim, Juwon; Yoon, Kap Joon; Lee, Jong-Han

    2018-04-17

    Transferrin is the major plasma transport protein for iron. We aimed to investigate the characteristics of transferrin variant by carbohydrate-deficient transferrin (CDT) test using capillary zone electrophoresis. We retrospectively analyzed the CDT tests of 2449 patients from March 2009 to May 2017 at a tertiary hospital in Korea. CDT was quantified using a Capillarys 2 system (Sebia, Lisses, France) by capillary zone electrophoresis. The characteristics of variant transferrin patterns using electropherogram of CDT tests were analyzed. Seventy-seven (3.1%) patients were classified as variant transferrin. Mean age of these patients was 51.8 years, and the male-to-female ratio was 3.5:1. The most common variants were the BC variants (n = 37), followed by the CD variants (n = 27), unclear patterns (n = 7), BD variants (n = 3), CC variants (n = 2), misclassification (n = 1). In the variant Tf group, the most common disease was alcoholic liver cirrhosis (n = 22, 28.6%), followed by the toxic effects of substances (n = 17, 22.1%), and mental and behavioral disorders attributable to alcohol (n = 11, 14.3%). Nonvariant group showed a predominance of the toxic substance effects (n = 880, 37.1%), a personal history of suicide attempts (n = 634, 26.7%), and mental and behavioral disorders due to alcohol (n = 336, 14.2%). We analyzed the basic characteristics of variant transferrin by CDT tests using capillary zone electrophoresis. The prevalence of variant transferrin was 3.1% of the study subjects. Male patients, alcohol abusers, and liver cirrhosis patients predominated in the variant transferrin population. Further prospective studies are warranted to elucidate variant transferrin in clinical practice. © 2018 Wiley Periodicals, Inc.

  20. Free flow electrophoresis separation and AMS quantitation of {sup 14}C-naphthalene-protein adducts

    Energy Technology Data Exchange (ETDEWEB)

    Buchholz, Bruce A., E-mail: bbuchholz@llnl.go [Center for AMS, LLNL, 7000 East Avenue, Livermore, CA 94551 (United States); Haack, Kurt W.; Sporty, Jennifer L. [Center for AMS, LLNL, 7000 East Avenue, Livermore, CA 94551 (United States); Buckpitt, Alan R.; Morin, Dexter [Department of Molecular Biosciences, School of Veterinary Medicine, UC Davis, Davis, CA 95616 (United States)

    2010-04-15

    Naphthalene is a volatile aromatic hydrocarbon to which humans are exposed from a variety of sources including mobile air sources and cigarette smoke. Naphthalene produces dose-(concentration)dependent injury to airway epithelial cells of murine lung which is observed at concentrations well below the current occupational exposure standard. Toxicity is dependent upon the cytochrome P450 mediated metabolic activation of the parent substrate to unstable metabolites which become bound covalently to tissue proteins. Nearly 70 proteins have been identified as forming adducts with reactive naphthalene metabolites using in vitro systems but very little work has been conducted in vivo because reasonably large amounts (100 muCi) of {sup 14}C labeled parent compound must be administered to generate detectable adduct levels on storage phosphor screens following separation of labeled proteins by 2D gel electrophoresis. The work described here was done to provide proof of concept that protein separation by free flow electrophoresis followed by AMS detection of protein fractions containing protein bound reactive metabolites would provide adducted protein profiles in animals dosed with trace quantities of labeled naphthalene. Mice were administered 200 mg/kg naphthalene intraperitoneally at a calculated specific activity of 2 DPM/nmol (1 pCi/nmol) and respiratory epithelial tissue was obtained by lysis lavage 4 h post injection. Free flow electrophoresis (FFE) separates proteins in the liquid phase over a large pH range (2.5-11.5) using low molecular weight acids and bases to modify the pH. The apparatus separates fractions into standard 96-well plates that can be used in other protein analysis techniques. The buffers of the fractions have very high carbon content, however, and need to be dialyzed to yield buffers compatible with {sup 14}C-AMS. We describe the processing techniques required to couple FFE to AMS for quantitation of protein adducts.