WorldWideScience

Sample records for revision hip arthroplasty

  1. Revision for prosthetic joint infection following hip arthroplasty: Evidence from the National Joint Registry.

    Science.gov (United States)

    Lenguerrand, E; Whitehouse, M R; Beswick, A D; Jones, S A; Porter, M L; Blom, A W

    2017-06-01

    We used the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man (NJR) to investigate the risk of revision due to prosthetic joint infection (PJI) for patients undergoing primary and revision hip arthroplasty, the changes in risk over time, and the overall burden created by PJI. We analysed revision total hip arthroplasties (THAs) performed due to a diagnosis of PJI and the linked index procedures recorded in the NJR between 2003 and 2014. The cohort analysed consisted of 623 253 index primary hip arthroplasties, 63 222 index revision hip arthroplasties and 7585 revision THAs performed due to a diagnosis of PJI. The prevalence, cumulative incidence functions and the burden of PJI (total procedures) were calculated. Overall linear trends were investigated with log-linear regression. We demonstrated a prevalence of revision THA due to prosthetic joint infection of 0.4/100 procedures following primary and 1.6/100 procedures following revision hip arthroplasty. The prevalence of revision due to PJI in the three months following primary hip arthroplasty has risen 2.3-fold (95% confidence interval (CI) 1.3 to 4.1) between 2005 and 2013, and 3.0-fold (95% CI 1.1 to 8.5) following revision hip arthroplasty. Over 1000 procedures are performed annually as a consequence of hip PJI, an increase of 2.6-fold between 2005 and 2013. Although the risk of revision due to PJI following hip arthroplasty is low, it is rising and, coupled with the established and further predicted increased incidence of both primary and revision hip arthroplasty, this represents a growing and substantial treatment burden. Cite this article : E. Lenguerrand, M. R. Whitehouse, A. D. Beswick, S. A. Jones, M. L. Porter, A. W. Blom. Revision for prosthetic joint infection following hip arthroplasty: Evidence from the National Joint Registry. Bone Joint Res 2017;6:391-398. DOI: 10.1302/2046-3758.66.BJR-2017-0003.R1. © 2017 Lenguerrand et al.

  2. Conversion total hip arthroplasty: Primary or revision total hip arthroplasty

    Science.gov (United States)

    Schwarzkopf, Ran; Baghoolizadeh, Mahta

    2015-01-01

    Total hip arthroplasty (THA) is an increasingly common procedure among elderly individuals. Although conversion THA is currently bundled in a diagnosis related group (DRG) with primary THA, there is a lack of literature supporting this classification and it has yet to be identified whether conversion THA better resembles primary or revision THA. This editorial analyzed the intraoperative and postoperative factors and functional outcomes following conversion THA, primary THA, and revision THA to understand whether the characteristics of conversion THA resemble one procedure or the other, or are possibly somewhere in between. The analysis revealed that conversion THA requires more resources both intraoperatively and postoperatively than primary THA. Furthermore, patients undergoing conversion THA present with poorer functional outcomes in the long run. Patients undergoing conversion THA better resemble revision THA patients than primary THA patients. As such, patients undergoing conversion THA should not be likened to patients undergoing primary THA when determining risk stratification and reimbursement rates. Conversion THA procedures should be planned accordingly with proper anticipation of the greater needs both in the operating room, and for in-patient and follow-up care. We suggest that conversion THA be reclassified in the same DRG with revision THA as opposed to primary THA as a step towards better allocation of healthcare resources for conversion hip arthroplasties. PMID:26601055

  3. What Is the Rerevision Rate After Revising a Hip Resurfacing Arthroplasty? Analysis From the AOANJRR.

    Science.gov (United States)

    Wong, James Min-Leong; Liu, Yen-Liang; Graves, Stephen; de Steiger, Richard

    2015-11-01

    More than 15,000 primary hip resurfacing arthroplasties have been recorded by the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) with 884 primary procedures requiring revision for reasons other than infection, a cumulative percent revision rate at 12 years of 11%. However, few studies have reported the survivorship of these revision procedures. (1) What is the cumulative percent rerevision rate for revision procedures for failed hip resurfacings? (2) Is there a difference in rerevision rate among different types of revision or bearing surfaces? The AOANJRR collects data on all primary and revision hip joint arthroplasties performed in Australia and after verification against health department data, checking of unmatched procedures, and subsequent retrieval of unreported procedures is able to obtain an almost complete data set relating to hip arthroplasty in Australia. Revision procedures are linked to the known primary hip arthroplasty. There were 15,360 primary resurfacing hip arthroplasties recorded of which 884 had undergone revision and this was the cohort available to study. The types of revisions were acetabular only, femoral only, or revision of both acetabular and femoral components. With the exception of the acetabular-only revisions, all revisions converted hip resurfacing arthroplasties to conventional (stemmed) total hip arthroplasties (THAs). All initial revisions for infection were excluded. The survivorship of the different types of revisions and that of the different bearing surfaces used were estimated using the Kaplan-Meier method and compared using Cox proportional hazard models. Cumulative percent revision was calculated by determining the complement of the Kaplan-Meier survivorship function at that time multiplied by 100. Of the 884 revisions recorded, 102 underwent further revision, a cumulative percent rerevision at 10 years of 26% (95% confidence interval, 19.6-33.5). There was no difference in the rate of

  4. Effect of hydroxyapatite coating on risk of revision after primary total hip arthroplasty in younger patients: findings from the Danish Hip Arthroplasty Registry

    DEFF Research Database (Denmark)

    Paulsen, Aksel; Pedersen, Alma B; Johnsen, Søren P

    2007-01-01

    BACKGROUND: The effect of hydroxyapatite (HA) on implant survival in the medium and long term is uncertain. We studied the effect of HA coating of uncemented implants on the risk of cup and stem revision in primary total hip arthroplasty (THA). PATIENTS AND METHODS: Using the Danish Hip Arthropla......BACKGROUND: The effect of hydroxyapatite (HA) on implant survival in the medium and long term is uncertain. We studied the effect of HA coating of uncemented implants on the risk of cup and stem revision in primary total hip arthroplasty (THA). PATIENTS AND METHODS: Using the Danish Hip...

  5. [Revision hip arthroplasty by Waldemar Link custom-made total hip prosthesis].

    Science.gov (United States)

    Medenica, Ivica; Luković, Milan; Radoicić, Dragan

    2010-02-01

    The number of patients undergoing hip arthroplasty revision is constantly growing. Especially, complex problem is extensive loss of bone stock and pelvic discontinuity that requires reconstruction. The paper presented a 50-year old patient, who ten years ago underwent a total cement artrhroplasty of the left hip. A year after the primary operation the patient had difficulties in walking without crutches. Problems intensified in the last five years, the patient had severe pain, totally limited movement in the left hip and could not walk at all. Radiographically, we found loose femoral component, massive loss of bone stock of proximal femur, acetabular protrusion and a consequent pelvic discontinuity. Clinically, a completely disfunctional left hip joint was registered (Harris hip score--7.1). We performed total rearthroplasty by a custom-made Waldemar Link total hip prosthesis with acetabular antiprotrusio cage and compensation of bone defects with a graft from the bone bank. A year after the operation, we found clinically an extreme improvement in Harris hip score--87.8. Radiographically, we found stability of implanted components, a complete graft integration and bone bridging across the site of pelvic discontinuity. Pelvic discontinuity and massive loss of proximal femoral bone stock is a challenging and complex entity. Conventional prostheses cannot provide an adequate fixation and stability of the hip. Application of custom-made prosthesis (measured specificaly for a patient) and additional alografting bone defects is a good method in revision surgery after unsuccessful hip arthroplasty with extensive bone defects.

  6. Chronic infections in hip arthroplasties

    DEFF Research Database (Denmark)

    Lange, Jeppe; Troelsen, Anders; Thomsen, Reimar W

    2012-01-01

    Two-stage revision is regarded by many as the best treatment of chronic infection in hip arthroplasties. Some international reports, however, have advocated one-stage revision. No systematic review or meta-analysis has ever compared the risk of reinfection following one-stage and two-stage revisi......Two-stage revision is regarded by many as the best treatment of chronic infection in hip arthroplasties. Some international reports, however, have advocated one-stage revision. No systematic review or meta-analysis has ever compared the risk of reinfection following one-stage and two......-stage revisions for chronic infection in hip arthroplasties....

  7. Revision hip arthroplasty by Waldemar Link custom-made total hip prosthesis

    Directory of Open Access Journals (Sweden)

    Medenica Ivica

    2010-01-01

    Full Text Available Background. The number of patients undergoing hip arthroplasty revision is constantly growing. Especially, complex problem is extensive loss of bone stock and pelvic discontinuity that requires reconstruction. Case report. The paper presented a 50-year old patient, who ten years ago underwent a total cement artrhroplasty of the left hip. A year after the primary operation the patient had difficulties in walking without crutches. Problems intensified in the last five years, the patient had severe pain, totally limited movement in the left hip and could not walk at all. Radiographically, we found loose femoral component, massive loss of bone stock of proximal femur, acetabular protrusion and a consequent pelvic discontinuity. Clinically, a completely disfunctional left hip joint was registered (Harris hip score - 7.1. We performed total rearthroplasty by a custom- made Waldemar Link total hip prosthesis with acetabular antiprotrusio cage and compensation of bone defects with a graft from the bone bank. A year after the operation, we found clinically an extreme improvement in Harris hip score - 87.8. Radiographically, we found stability of implanted components, a complete graft integration and bone bridging across the site of pelvic discontinuity. Conclusion. Pelvic discontinuity and massive loss of proximal femoral bone stock is a challenging and complex entity. Conventional prostheses cannot provide an adequate fixation and stability of the hip. Application of custom-made prosthesis (measured specifically for a patient and additional alografting bone defects is a good method in revision surgery after unsuccessful hip arthroplasty with extensive bone defects.

  8. Use of massive structural allograft in revision septic hip arthroplasty

    International Nuclear Information System (INIS)

    Imran Ilyas; Morgan, F.; David, A.

    1999-01-01

    The reconstruction of failed septic hip arthroplasty with the use of massive osseous allograft segments is reported in ten patients. All of these patients had a two-stage procedure with an interval Girdlestone arthroplasty separating the initial demolition from the subsequent reconstruction. The mean follow-up was 58 months (range 36 to 98 months) and the most common pathogen isolated was Staphylococcus epidermidis. The mean preoperative modified Harris hip score was 27 points (range 9 to 58) and the mean postoperative score was 73 points (range 53 to 92). There was one patient who required an additional procedure not related to allograft use. There has been no case of recurrence of infection. We conclude that the revision of septic hip arthroplasty in the use of massive allografts do not have to be mutually exclusive events

  9. The Danish Hip Arthroplasty Register

    DEFF Research Database (Denmark)

    Gundtoft, Per Hviid; Varnum, Claus; Pedersen, Alma Becic

    2016-01-01

    AIM OF DATABASE: The aim of the Danish Hip Arthroplasty Register (DHR) is to continuously monitor and improve the quality of treatment of primary and revision total hip arthroplasty (THA) in Denmark. STUDY POPULATION: The DHR is a Danish nationwide arthroplasty register established in January 1995...

  10. Bioball universal modular neck adapter as a salvage for failed revision total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Raju Vaishya

    2013-01-01

    Full Text Available Management of recurrent dislocation of total hip arthroplasty is often a challenging and daunting task. Re-revision of such a total hip prosthesis may not be easy as the removal of a well-fixed, fully coated stem is extremely difficult. We managed to salvage instability in three revision hip cases in which the fully coated stem had subsided by using a bioball universal neck adapter without changing the femoral stem or acetabular cup.

  11. Revision total hip arthoplasty: factors associated with re-revision surgery.

    Science.gov (United States)

    Khatod, Monti; Cafri, Guy; Inacio, Maria C S; Schepps, Alan L; Paxton, Elizabeth W; Bini, Stefano A

    2015-03-04

    The survivorship of implants after revision total hip arthroplasty and risk factors associated with re-revision are not well defined. We evaluated the re-revision rate with use of the institutional total joint replacement registry. The purpose of this study was to determine patient, implant, and surgeon factors associated with re-revision total hip arthroplasty. A retrospective cohort study was conducted. The total joint replacement registry was used to identify patients who had undergone revision total hip arthroplasty for aseptic reasons from April 1, 2001, to December 31, 2010. The end point of interest was re-revision total hip arthroplasty. Risk factors evaluated for re-revision total hip arthroplasty included: patient risk factors (age, sex, body mass index, race, and general health status), implant risk factors (fixation type, bearing surface, femoral head size, and component replacement), and surgeon risk factors (volume and experience). A multivariable Cox proportional hazards model was used. Six hundred and twenty-nine revision total hip arthroplasties with sixty-three (10%) re-revisions were evaluated. The mean cohort age (and standard deviation) was 57.0 ± 12.4 years, the mean body mass index (and standard deviation) was 29.5 ± 6.1 kg/m(2), and most of the patients were women (64.5%) and white (81.9%) and had an American Society of Anesthesiologists score of associated with the risk of re-revision. For every ten-year increase in patient age, the hazard ratio for re-revision decreases by a factor of 0.72 (95% confidence interval, 0.58 to 0.90). For every five revision surgical procedures performed by a surgeon, the risk of revision decreases by a factor of 0.93 (95% confidence interval, 0.86 to 0.99). At the time of revision, a new or retained cemented femoral implant or all-cemented hip implant increases the risk of revision by a factor of 3.19 (95% confidence interval, 1.22 to 8.38) relative to a retained or new uncemented hip implant. A ceramic on a

  12. Revision of cemented hip arthroplasty using a hydroxyapatite-ceramic-coated femoral component.

    Science.gov (United States)

    Raman, R; Kamath, R P; Parikh, A; Angus, P D

    2005-08-01

    We report the clinical and radiological outcome of 86 revisions of cemented hip arthroplasties using JRI-Furlong hydroxyapatite-ceramic-coated acetabular and femoral components. The acetabular component was revised in 62 hips and the femoral component in all hips. The mean follow-up was 12.6 years and no patient was lost to follow-up. The mean age of the patients was 71.2 years. The mean Harris hip and Oxford scores were 82 (59 to 96) and 23.4 (14 to 40), respectively. The mean Charnley modification of the Merle d'Aubigné and Postel score was 5 (3 to 6) for pain, 4.9 (3 to 6) for movement and 4.4 (3 to 6) for mobility. Migration of the acetabular component was seen in two hips and the mean acetabular inclination was 42.6 degrees. The mean linear polyethylene wear was 0.05 mm/year. The mean subsidence of the femoral component was 1.9 mm and stress shielding was seen in 23 (28%) with bony ingrowth in 76 (94%). Heterotopic ossification was seen in 12 hips (15%). There were three re-revisions, two for deep sepsis and one for recurrent dislocation and there were no re-revisions for aseptic loosening. The mean EuroQol EQ-5D description scores and health thermometer scores were 0.69 (0.51 to 0.89) and 79 (54 to 95), respectively. With an end-point of definite or probable loosening, the probability of survival at 12 years was 93.9% and 95.6% for the acetabular and femoral components, respectively. Overall survival at 12 years, with removal or further revision of either component for any reason as the end-point, was 92.3%. Our study supports the continued use of this arthroplasty and documents the durability of hydroxyapatite-ceramic-coated components.

  13. 3D Printing Aids Acetabular Reconstruction in Complex Revision Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Andrew J. Hughes

    2017-01-01

    Full Text Available Revision hip arthroplasty requires comprehensive appreciation of abnormal bony anatomy. Advances in radiology and manufacturing technology have made three-dimensional (3D representation of osseous anatomy obtainable, which provide visual and tactile feedback. Such life-size 3D models were manufactured from computed tomography scans of three hip joints in two patients. The first patient had undergone multiple previous hip arthroplasties for bilateral hip infections, resulting in right-sided pelvic discontinuity and a severe left-sided posterosuperior acetabular deficiency. The second patient had a first-stage revision for infection and recurrent dislocations. Specific metal reduction protocols were used to reduce artefact. The images were imported into Materialise MIMICS 14.12®. The models were manufactured using selective laser sintering. Accurate templating was performed preoperatively. Acetabular cup, augment, buttress, and cage sizes were trialled using the models, before being adjusted, and resterilised, enhancing the preoperative decision-making process. Screw trajectory simulation was carried out, reducing the risk of neurovascular injury. With 3D printing technology, complex pelvic deformities were better evaluated and treated with improved precision. Life-size models allowed accurate surgical simulation, thus improving anatomical appreciation and preoperative planning. The accuracy and cost-effectiveness of the technique should prove invaluable as a tool to aid clinical practice.

  14. Revision Total Hip Arthroplasty Using a Modular Tapered Stem With Distal Fixation Good Short-Term Results in 125 Revisions

    DEFF Research Database (Denmark)

    Ovesen, Ole; Emmeluth, Claus; Hofbauer, Christian

    2009-01-01

    After 2 to 7 years we reviewed 125 prosthetic hip arthroplasty stem revisions using a modular tapered stem with distal fixation. Median age of these patients was 68 (33-92) years. Baseline and follow-up data were registered prospectively according to the Danish Hip Arthroplasty Registry. Survival...... system is very versatile, can be used in most femoral revision cases, and allows rapid bone remodeling. We did not find an increased number of complications compared to the literature. Further long-term follow-up, however, is essential......., free of any rerevision, was 94%. Harris Hip Score improved from average 44 to 85. Bony regeneration was an early and significant finding in most cases. Complications included 4 (3%) fractures intraoperatively and 8 (6%) dislocations, 4 (3%) deep infections, and 1 (1%) stem fracture. This modular taper...

  15. Should gram stains have a role in diagnosing hip arthroplasty infections?

    Science.gov (United States)

    Johnson, Aaron J; Zywiel, Michael G; Stroh, D Alex; Marker, David R; Mont, Michael A

    2010-09-01

    The utility of Gram stains in diagnosing periprosthetic infections following total hip arthroplasty has recently been questioned. Several studies report low sensitivity of the test, and its poor ability to either confirm or rule out infection in patients undergoing revision total hip arthroplasty. Despite this, many institutions including that of the senior author continue to perform Gram stains during revision total hip arthroplasty. We assessed the sensitivity, specificity, accuracy, and positive and negative predictive values of Gram stains from surgical-site samplings taken from procedures on patients with both infected and aseptic revision total hip arthroplasties. A review was performed on patients who underwent revision total hip arthroplasty between 2000 and 2007. Eighty-two Gram stains were performed on patients who had infected total hip arthroplasties and underwent revision procedures. Additionally, of the 410 revision total hip arthroplasties performed on patients who were confirmed infection-free, 120 Gram stains were performed. Patients were diagnosed as infected using multiple criteria at the time of surgery. Sensitivity, specificity, positive and negative predictive values, and accuracy were calculated from these Gram stain results. The Gram stain demonstrated a sensitivity and specificity of 9.8% and 100%, respectively. In this series, the Gram stain had a negative predictive value of 62%, a positive predictive value of 100%, and an accuracy of 63%. Gram stains obtained from surgical-site samples had poor sensitivity and poor negative predictive value. Based on these findings, as well as those of other authors, we believe that Gram stains should no longer be considered for diagnosing infections in revision total hip arthroplasty. Level III, diagnostic study. See Guidelines for Authors for a complete description of levels of evidence.

  16. Low revision rate after total hip arthroplasty in patients with pediatric hip diseases

    DEFF Research Database (Denmark)

    Engesæter, Lars B; Engesæter, Ingvild Ø; Fenstad, Anne Marie

    2012-01-01

    Background The results of primary total hip arthroplasties (THAs) after pediatric hip diseases such as developmental dysplasia of the hip (DDH), slipped capital femoral epiphysis (SCFE), or Perthes' disease have been reported to be inferior to the results after primary osteoarthritis of the hip (OA.......9%) were operated due to pediatric hip diseases (3.1% for Denmark, 8.8% for Norway, and 1.9% for Sweden) and 288,435 THAs (77.8%) were operated due to OA. Unadjusted 10-year Kaplan-Meier survival of THAs after pediatric hip diseases (94.7% survival) was inferior to that after OA (96.6% survival......). Consequently, an increased risk of revision for hips with a previous pediatric hip disease was seen (risk ratio (RR) 1.4, 95% CI: 1.3-1.5). However, after adjustment for differences in sex and age of the patients, and in fixation of the prostheses, no difference in survival was found (93.6% after pediatric hip...

  17. The association between metal allergy, total hip arthroplasty, and revision

    DEFF Research Database (Denmark)

    Thyssen, Jacob Pontoppidan; Jakobsen, Stig Storgaard; Engkilde, Kåre

    2009-01-01

    BACKGROUND AND PURPOSE: It has been speculated that the prevalence of metal allergy may be higher in patients with implant failure. We compared the prevalence and cause of revisions following total hip arthroplasty (THA) in dermatitis patients suspected to have contact allergy and in patients...... in general with THA. Furthermore, we compared the prevalence of metal allergy in dermatitis patients with and without THA. MATERIALS AND METHODS: The Danish Hip Arthroplasty Registry (DHAR) contained detailed information on 90,697 operations. The Gentofte patch-test database contained test results...... was similar in cases (12%) and in patients from the DHAR (13%). The prevalence of metal allergy was similar in cases and controls. However, the prevalence of metal allergy was lower in cases who were patch-tested after operation (6%) than in those who were patch-tested before operation (16%) (OR = 2.9; 95% CI...

  18. Revision Total Hip Arthoplasty: Factors Associated with Re-Revision Surgery

    OpenAIRE

    Khatod, M; Cafri, G; Inacio, MCS; Schepps, AL; Paxton, EW; Bini, SA

    2015-01-01

    The survivorship of implants after revision total hip arthroplasty and risk factors associated with re-revision are not well defined. We evaluated the re-revision rate with use of the institutional total joint replacement registry. The purpose of this study was to determine patient, implant, and surgeon factors associated with re-revision total hip arthroplasty.A retrospective cohort study was conducted. The total joint replacement registry was used to identify patients who had undergone revi...

  19. Risk factors for revision of primary total hip arthroplasty: a systematic review

    Directory of Open Access Journals (Sweden)

    Prokopetz Julian JZ

    2012-12-01

    Full Text Available Abstract Background Numerous papers have been published examining risk factors for revision of primary total hip arthroplasty (THA, but there have been no comprehensive systematic literature reviews that summarize the most recent findings across a broad range of potential predictors. Methods We performed a PubMed search for papers published between January, 2000 and November, 2010 that provided data on risk factors for revision of primary THA. We collected data on revision for any reason, as well as on revision for aseptic loosening, infection, or dislocation. For each risk factor that was examined in at least three papers, we summarize the number and direction of statistically significant associations reported. Results Eighty-six papers were included in our review. Factors found to be associated with revision included younger age, greater comorbidity, a diagnosis of avascular necrosis (AVN as compared to osteoarthritis (OA, low surgeon volume, and larger femoral head size. Male sex was associated with revision due to aseptic loosening and infection. Longer operating time was associated with revision due to infection. Smaller femoral head size was associated with revision due to dislocation. Conclusions This systematic review of literature published between 2000 and 2010 identified a range of demographic, clinical, surgical, implant, and provider variables associated with the risk of revision following primary THA. These findings can inform discussions between surgeons and patients relating to the risks and benefits of undergoing total hip arthroplasty.

  20. Revision rates for metal-on-metal hip resurfacing and metal-on-metal total hip arthroplasty – a systematic review

    DEFF Research Database (Denmark)

    Ras Sørensen, Sofie-amalie L.; Jørgensen, Henrik L.; Sporing, Sune L.

    2016-01-01

    Purpose To compare revision rates of metal-on-metal (MoM) hip resurfacing (HRS) and MoM total hip arthroplasty (THA), as well as the primary causes for revisions. Methods The PubMed database was queried for potentially relevant articles addressing MoMTHA and MoMHRS, a total of 51 articles were....... The odds ratio was 1.25 (1.03:1.53) 95% CI (p = 0.03) (MoMHRS vs. MoMTHA). The studies of hip prostheses were separated into 2 categories of short- and long-term (more or less than 5 years). Short-term revision rate for MoMTHA was 4.5% after 4.8 years, and for MoMHRS 4.0% after 4.2 years. The odds ratio...

  1. Age and Early Revision After Primary Total Hip Arthroplasty for Osteoarthritis.

    Science.gov (United States)

    Meyer, Zachary; Baca, Geneva; Rames, Richard; Barrack, Robert; Clohisy, John; Nam, Denis

    2017-11-01

    Prior reports have noted an increased risk of early revision among younger patients undergoing total hip arthroplasty (THA) but have been confounded by the inclusion of various diagnoses. The purpose of this study was to assess the revision rate and the time to revision for patients undergoing THA for osteoarthritis based on age. Patients with a diagnosis of osteoarthritis who underwent both primary and revision THA at the same institution were identified. The time between primary and revision surgery and the indication for revision were collected. Patients were stratified into 2 groups based on age at the time of primary THA: 64 years or younger (group 1) or 65 years or older (group 2). Between 1996 and 2016, a total of 4662 patients (5543 hips) underwent primary THA for a diagnosis of osteoarthritis. Of these, 100 patients (104 hips) received a revision THA (62 in group 1 and 42 in group 2). Mean age was 52.7±8.4 years in group 1 vs 73.4±6.3 years in group 2 (Pprimary to revision surgery was 3.0±3.2 years for group 1 and 1.1±2.1 years for group 2 (P=.001). Among patients undergoing primary THA for a diagnosis of osteoarthritis, younger age is not associated with an increased rate of early failure or revision. [Orthopedics. 2017; 40(6):e1069-e1073.]. Copyright 2017, SLACK Incorporated.

  2. [The Use of Jumbo Cups in Revision Total Hip Arthroplasty].

    Science.gov (United States)

    von Roth, Philipp; Wassilew, Georgi I

    2017-10-01

    Extra-large uncemented jumbo cups are among the most common methods of acetabular revision. Jumbo cups do not contribute to bone stock restoration, and in the case of a subsequent revision, an even larger bone defect is to be expected. Thus, understanding long-term survival is essential. The present article discusses the literature relevant to this topic and addresses technical and implant-specific characteristics of jumbo cups. In summary, jumbo cups show an acceptable long-term survival rate, with aseptic loosening as the most common reason for revision and dislocation being the most common complication. Through the development of alternative revision systems, jumbo cups have lost their importance in today's practice. However, they can serve as a benchmark for studies of newer technologies in revision total hip arthroplasty. Georg Thieme Verlag KG Stuttgart · New York.

  3. Cement augmentation in the proximal femur to prevent stem subsidence in revision hip arthroplasty with Paprosky type II/IIIa defects

    Directory of Open Access Journals (Sweden)

    Shang-Wen Tsai

    2018-06-01

    Full Text Available Background: Subsidence remains a common complication after revision hip arthroplasty which may lead to prolonged weight-bearing restrictions, leg-length discrepancies or considerable loss of function. We evaluated the effectiveness of cement augmentation in the proximal femoral metaphysis during a revision of femoral components to prevent post-operative stem subsidence. Methods: Forty patients were enrolled. Follow-up averaged 67.7 months (range: 24–149. Twenty-seven patients had a Paprosky type II defect and 13 had a type IIIa defect. All revision hip arthroplasty used a cementless, cylindrical, non-modular cobalt–chromium stem. The defect in the metaphysis was filled with antibiotic-loaded bone cement. Thirteen patients who had undergone stem revision only was allowed to walk immediately without weight-bearing restrictions. Twenty-seven patients who had undergone revision total hip arthroplasty was allowed partial weight-bearing within 6 weeks after surgery in the consideration of acetabular reconstruction. Results: Three patients (7.5% had post-surgery stem subsidences of three mm, five mm, and 10 mm, respectively, at three, one, and 14 months. There were no acute surgical site infections. There were three femoral stem failures: two delayed infections and one periprosthetic Vancouver B2 fracture. Both five- and 10-year survivorships of the femoral implant were 90.1%. Conclusion: An adequate length of the scratch-fit segment and diaphyseal ingrowth remain of paramount importance when revising femoral components. To fill metaphyseal bone defects with antibiotic-loaded bone cement may be an alternative method in dealing with proximal femoral bone loss during a femoral revision. Keywords: Bone defect, Cement augmentation, Femur, Revision hip arthroplasty, Subsidence

  4. Revision hip preservation surgery with hip arthroscopy: clinical outcomes.

    Science.gov (United States)

    Domb, Benjamin G; Stake, Christine E; Lindner, Dror; El-Bitar, Youseff; Jackson, Timothy J

    2014-05-01

    To analyze and report the clinical outcomes of a cohort of patients who underwent revision hip preservation with arthroscopy and determine predictors of positive and negative outcomes. During the study period from April 2008 to December 2010, all patients who underwent revision hip preservation with arthroscopy were included. This included patients who had previous open surgery and underwent revision with arthroscopy. Patient-reported outcome (PRO) scores were obtained preoperatively and at 3-month, 1-year, 2-year, and 3-year follow-up time points. Any revision surgeries and conversions to total hip arthroplasty were noted. A multiple regression analysis was performed to look for positive and negative predictive factors for improvement in PROs after revision hip arthroscopy. Forty-seven hips in 43 patients had completed 2 years' follow-up or needed total hip arthroplasty. The mean length of follow-up was 29 months (range, 24 to 47 months). Of the hips, 31 (66%) had either unaddressed or incompletely treated femoroacetabular impingement. There was a significant improvement in all PRO scores at a mean of 29 months after revision (P arthroscopy can achieve moderately successful outcomes and remains a viable treatment strategy after failed primary hip preservation surgery. Preoperative predictors of success after revision hip arthroscopy include segmental labral defects, unaddressed or incompletely addressed femoroacetabular impingement, heterotopic ossification, and previous open surgery. Level IV, therapeutic case series. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  5. Chronic infections in hip arthroplasties: comparing risk of reinfection following one-stage and two-stage revision: a systematic review and meta-analysis

    Directory of Open Access Journals (Sweden)

    Lange J

    2012-03-01

    Full Text Available Jeppe Lange1,2, Anders Troelsen3, Reimar W Thomsen4, Kjeld Søballe1,51Lundbeck Foundation Centre for Fast-Track Hip and Knee Surgery, Aarhus C, 2Center for Planned Surgery, Silkeborg Regional Hospital, Silkeborg, 3Department of Orthopaedics, Hvidovre Hospital, Hvidovre, 4Department of Clinical Epidemiology, Aarhus University Hospital, Aalborg, 5Department of Orthopaedics, Aarhus University Hospital, Aarhus C, DenmarkBackground: Two-stage revision is regarded by many as the best treatment of chronic infection in hip arthroplasties. Some international reports, however, have advocated one-stage revision. No systematic review or meta-analysis has ever compared the risk of reinfection following one-stage and two-stage revisions for chronic infection in hip arthroplasties.Methods: The review was performed in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analysis. Relevant studies were identified using PubMed and Embase. We assessed studies that included patients with a chronic infection of a hip arthroplasty treated with either one-stage or two-stage revision and with available data on occurrence of reinfections. We performed a meta-analysis estimating absolute risk of reinfection using a random-effects model.Results: We identified 36 studies eligible for inclusion. None were randomized controlled trials or comparative studies. The patients in these studies had received either one-stage revision (n = 375 or two-stage revision (n = 929. Reinfection occurred with an estimated absolute risk of 13.1% (95% confidence interval: 10.0%–17.1% in the one-stage cohort and 10.4% (95% confidence interval: 8.5%–12.7% in the two-stage cohort. The methodological quality of most included studies was considered low, with insufficient data to evaluate confounding factors.Conclusions: Our results may indicate three additional reinfections per 100 reimplanted patients when performing a one-stage versus two-stage revision. However, the

  6. The use of a tripolar articulation in revision total hip arthroplasty: a minimum of 24 months' follow-up.

    Science.gov (United States)

    Levine, Brett R; Della Valle, Craig J; Deirmengian, Carl A; Breien, Kristoffer M; Weeden, Steven H; Sporer, Scott M; Paprosky, Wayne G

    2008-12-01

    A retrospective cohort study of 31 hips revised with a tripolar articular construct was performed. Patient demographics and preoperative and postoperative information were recorded. Indications for a tripolar construct were recurrent dislocation and the inability to attain intraoperative stability during hip revision. Nine patients (29%) were revised to the tripolar construct after failure of a constrained liner. Twenty patients (65%) had at least one episode of instability before the most recent revision. At a mean follow-up of 38 months, modified Postel scores improved from a mean of 5.28 to 9.64 (P tripolar construct was effective in eliminating or preventing instability in 93% of the complex cases treated. These early results support the use of a tripolar construct in treating recurrent instability or instability encountered at the time of revision hip arthroplasty.

  7. Fast-track revision knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik; Otte, Niels Kristian Stahl; Kristensen, Billy B

    2011-01-01

    Abstract Background and purpose Fast-track surgery has reduced the length of hospital stay (LOS), morbidity, and convalescence in primary hip and knee arthroplasty (TKA). We assessed whether patients undergoing revision TKA for non-septic indications might also benefit from fast-track surgery....... Methods 29 patients were operated with 30 revision arthroplasties. Median age was 67 (34-84) years. All patients followed a standardized fast-track set-up designed for primary TKA. We determined the outcome regarding LOS, morbidity, mortality, and satisfaction. Results Median LOS was 2 (1-4) days...

  8. Preservation of the Acetabular Cup During Revision Total Hip Arthroplasty Using a Novel Mini-navigation Tool: A Case Report.

    Science.gov (United States)

    Vincent, John; Alshaygy, Ibrahim; Muir, Jeffrey M; Kuzyk, Paul

    2018-01-01

    While intraoperative navigation systems have been shown to improve outcomes in primary total hip arthroplasty (THA), their use in the context of revision has been largely overlooked. This case report presents the first documented use of an imageless navigation tool in the context of revision THA, and an unexpected benefit to the surgical procedure as a result. An 84-year-old female patient presented following five episodes of dislocation of the left hip and with pain in the left buttock, groin, and posterior aspect of her hip. Relevant surgical history included primary hip arthroplasty in 1999 and the first revision in 2014. Preoperative analysis revealed a constrained liner that had become disengaged and migrated inferiorly, lodging at the distal aspect of the femoral neck. Acetabular protrusion was also noted. The pre-operative plan included the replacement of the fragmented liner and likely of the acetabular cup due to hardware failure. Intraoperative assessment, however, revealed that the cup was in good condition and would be difficult to remove due to substantial bony ingrowth. With the assistance of imageless navigation, the orientation of the acetabular cup was determined and a new constrained liner was cemented into the preexisting acetabular component at an altered orientation, correcting anteversion by 7°. In revision hip arthroplasty cases, image-based navigation is limited by the presence of existing implants and corresponding metal artefact. This case demonstrates the successful use of an imageless navigation tool for revision surgery. Use of navigation led to the unexpected intraoperative discovery that the acetabular cup was in an acceptable state, and allowed the surgical team to correct the position of the cup using a constrained liner, thus preserving the cup. This significantly benefitted patient outcome, due to the risks associated with the removal of a firmly fixated acetabular cup. While more extensive research is required, this case

  9. CUSTOMIZED ACETABULAR COMPONENTS IN REVISION HIP ARTHROPLASTY

    Directory of Open Access Journals (Sweden)

    G. M. Kavalersky

    2016-01-01

    Full Text Available In recent years, there is a trend of increasing demand for revision hip arthroplasty. Among these patients there are many with complex acetabular defects, including patients with pelvic discontinuity. To ensure stability for revised acetabular components in such cases becomes a challenging or unachievable task. Such defects give indications for printing customized tri-flange acetabular component. The authors analysed own experience of creating and applying custom made acetabular components in 3 patients with complex acetabular defects. Material and methods. Among the patients there were 2 women and 1 man. Average age was 60,3±19,4 years (38 to 78 years. Two patients had III B defects with pelvic discontinuity and one patient had III A defect by Paprosky classification. As the first step, the authors in collaboration with engineers printed a plaster full size pelvic 3D model, as the second step a customized tri-flange acetabular component was designed and printed. Harris Hip Score was evaluated preoperatively and 3 months postoperatively. Results. Average follow-up period was 5,3±2,5 months (3 to 8 months. The authors observed no cases of implant loosening, dislocation or deep periprosthetic infection. Average Harris Hip Score before surgery was 27,13 and after surgery – 74,1 indicating a significant improvement in 3 months postoperatively. Conclusion. Indications for use of individual acetabular components in reported patients correspond to indications formulated by Berasi et al. The authors obtained encouraging early follow-up outcomes that correspond to data of other authors. In one patient certain difficulties were reported due to insufficient pelvic distraction. Component’s flanges prevented achieving adequate pelvic distraction. Nevertheless, good primary stability was achieved. Modern software and 3D metal printers can significantly reduce the production cost of customized acetabular components. Application of this technology can be

  10. Fast-track revision knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik; Otte, Niels Kristian Stahl; Kristensen, Billy B

    2011-01-01

    Abstract Background and purpose Fast-track surgery has reduced the length of hospital stay (LOS), morbidity, and convalescence in primary hip and knee arthroplasty (TKA). We assessed whether patients undergoing revision TKA for non-septic indications might also benefit from fast-track surgery...

  11. Satisfactory Results of the Exeter Revision Femoral Stem Used for Primary Total Hip Arthroplasty.

    Science.gov (United States)

    Desy, Nicholas M; Johnson, Joshua D; Sierra, Rafael J

    2017-02-01

    The Exeter cemented femoral stem has demonstrated excellent clinical and radiographic outcomes as well as long-term survivorship free from aseptic loosening. A shorter revision stem (125 mm) with a 44 offset became available for the purpose of cement-in-cement revision situations. In certain cases, this shorter revision stem may be used for various primary total hip arthroplasties (THAs) where the standard length stem would require distally reaming the femoral canal. We sought to report on the early to midterm results of this specific stem when used for primary THA regarding (1) clinical and radiographic outcomes, (2) complications, and (3) survivorship. Twenty-nine patients (33 hips) underwent a hybrid THA using the smaller revision Exeter cemented femoral stem. Twenty-five patients (28 hips) had at least 2 years of follow-up and were assessed for clinical and radiographic outcomes. All 33 hips were included in the analysis of complications and survivorship. The Kaplan-Meier survivorship was performed using revision for all causes and for aseptic loosening as the end points. The average clinical follow-up was 4 years (range, 2-7). Harris Hip Scores improved from a mean preoperative value of 56 (range, 23-96) to 90 (range, 51-100) at the latest follow-up. All patients demonstrated superior cement mantles with no signs of loosening. One patient suffered a B2 periprosthetic fracture and 1 patient experienced 2 episodes of instability. The 5-year Kaplan-Meier survivorship was 96.7% for all causes of revision and was 100% using aseptic loosening as the end point. The shorter Exeter revision cemented femoral stem has favorable early to midterm clinical and radiographic outcomes when used for primary THA with a low complication rate and is a viable option in patients with narrow femoral canals where uncemented stem fixation is not desired. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Bone-preserving total hip arthroplasty in avascular necrosis of the hip-a matched-pairs analysis.

    Science.gov (United States)

    Merschin, David; Häne, Richard; Tohidnezhad, Mersedeh; Pufe, Thomas; Drescher, Wolf

    2018-07-01

    Short-stem hip arthroplasty has the potential advantage of femoral bone stock preservation, especially in view of the expected revisions in the often relatively young patients. Despite short-stem hip prosthesis are increasingly used for total hip arthroplasty, there are no sufficient mid- and long-term results especially for patients with avascular femoral head osteonecrosis. The present study investigates mid-term functional results as well as the revision rate following implantation of a short-stem prosthesis. In the period 06/2005 until 12/2013, a total of 351 short-stem hip prostheses were implanted. The study included 331 complete data sets. A retrospective analysis was performed using the Oxford Hip Score. All revisions were registered. In a total of 331 prostheses, the Oxford Hip Score was "excellent" in 66.2%, "good" in 12.7%, "fair" in 13.0%, and "poor" in 8.2% with a mean follow-up of 57.4 months (SD ± 29.8; range 24-115). In 26 cases, aseptic osteonecrosis of the hip was the indication (7.9%). The Oxford Hip Score was "excellent" in 66.7%, "good" in 0.0%, "fair" in 20.8%, and "poor" in 12.5%. The cumulated five year survival rate was 96.7%. In mid-term observation, the Metha® short-stem prosthesis shows no disadvantage in functional outcome and in survival time compared to a standard hip stem. Providing a correct indication, the Metha® short stem is a valuable option in total hip arthroplasty for younger patients with avascular osteonecrosis of the femoral head. Evaluation has shown no significant differences between aseptic osteonecrosis and other indications.

  13. Allogenic bone graft viability after hip revision arthroplasty assessed by dynamic [18F]fluoride ion positron emission tomography

    International Nuclear Information System (INIS)

    Piert, M.; Becker, H.D.; Winter, E.; Becker, G.A.; Bilger, K.; Machulla, H.J.; Mueller-Schauenburg, W.; Bares, R.

    1999-01-01

    The biological fate of allogenic bone grafts in the acetabular cavity and their metabolic activity after acetabular augmentation is uncertain but is most important for the stability of hip implants after hip revision arthroplasty. The aim of this study was to quantify regional bone metabolism after hip replacement operations. Dynamic [ 18 F]fluoride ion positron emission tomography (PET) was used to investigate the metabolic activity of acetabular allogenic bone grafts and genuine bone, either 3-6 weeks (short-term group, n = 9) or 5 months to 9 years (long-term group, n = 10) after hip revision arthroplasty. Applying a three-compartment model, the fluoride influx constant was calculated from individually fitted rate constants (K nlf ) and by Patlak graphical analysis (K pat ). The results were compared with genuine cancellous and cortical acetabular bone of contralateral hips without surgical trauma (n = 7). In genuine cortical bone, K nlf was significantly increased in short- (+140.9%) and long-term (+100.0%) groups compared with contralateral hips. Allogenic bone grafts were characterised by a significantly increased K nlf in the short-term group (+190.9%) compared with contralateral hips, but decreased almost to the baseline levels of contralateral hips (+45.5%) in the long-term. Values of K nlf cor-related with the rate constant K 1 in genuine (r = 0.89, P pat values were highly correlated with K nlf measurements in all regions. (orig.)

  14. Fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik

    2012-01-01

    Fast-track hip and knee arthroplasty aims at giving the patients the best available treatment at all times, being a dynamic entity. Fast-track combines evidence-based, clinical features with organizational optimization including a revision of traditions resulting in a streamlined pathway from...... on clinical and organizational aspects of fast-track hip and knee arthroplasty (I–IX). A detailed description of the fast-track set-up and its components is provided. Major results include identification of patient characteristics to predict length of stay and satisfaction with different aspects...... of the hospital stay (I); how to optimize analgesia by using a compression bandage in total knee arthroplasty (II); the clinical and organizational set-up facilitating or acting as barriers for early discharge (III); safety aspects following fast-track in the form of few readmissions in general (IV) and few...

  15. Bipolar hip arthroplasty as salvage treatment for loosening of the acetabular cup with significant bone defects

    Directory of Open Access Journals (Sweden)

    Ghanem, Mohamed

    2016-04-01

    Full Text Available Introduction: Revision arthroplasty of the hip is becoming increasingly important in recent years. Early primary arthroplasty and longer life expectancy of the patients increases the number of revision surgery. Revision surgery of hip arthroplasty is major surgery for the patients, especially the elderly, with significant risks concerning the general condition of the patient. The aim of this work is to evaluate the outcome of bipolar hip arthroplasty as a salvage procedure for treatment of loosening of the acetabular cup with significant acetabular bone defects after total hip replacement (THR in multi-morbid patients.Patients and methods: During the period from January 1 2007 to December 31 2011 19 revision hip surgeries were performed in , in which the loosened acetabular cup was replaced by a bipolar head. The examined patient group consisted exclusively of female patients with an average of 75 years. The predominant diagnosis was “aseptic loosening” (84.2%. All patients in our study were multi-morbid. We decided to resort to bipolar hip arthroplasty due to the compromised general condition of patients and the major acetabular bone defects, which were confirmed intraoperatively. The postoperative follow-up ranged from 0.5 to 67 months (average 19.1 months. Results: Evaluation of the modified Harris Hip Score showed an overall improvement of the function of the hip joint after surgery of approximately 45%.Surgery was less time consuming and thus adequate for patients with significantly poor general health condition. We noticed different complications in a significant amount of patients (68.4%. The most common complication encountered was the proximal migration of the bipolar head.The rate of revision following the use of bipolar hip arthroplasty in revision surgery of the hip in our patients was high (21%. Despite the high number of complications reported in our study, we have noticed significant improvement of hip joint function as well

  16. Transfusion practice in hip arthroplasty - a nationwide study

    DEFF Research Database (Denmark)

    Jans, Øivind; Kehlet, H; Hussain, Zubair Butt

    2011-01-01

    ) in Denmark. Materials and Methods We performed a retrospective cohort study of all patients undergoing THA or RTHA in Denmark in 2008. Primary outcomes were intercentre variation in red blood cell (RBC) transfusion rates and the timing of transfusion related to surgery. Results Six thousand nine hundred......Background and Objectives The optimal transfusion strategy in hip arthroplasty remains controversial despite existing guidelines. The aim of this study was to evaluate the transfusion practice in patients undergoing primary total hip arthroplasty (THA) or revision total hip arthroplasty (RTHA...... thirty-two THA patients and 1132 RTHA patients were included for analysis of which 1674 (24%) THA and 689 (61%) RTHA patients received RBC transfusion. Of these, 47% of THA and 73% of RTHA patients received transfusion on the day of surgery. Transfusion rates between centres varied from 7 to 71...

  17. Increasing risk of prosthetic joint infection after total hip arthroplasty

    DEFF Research Database (Denmark)

    Dale, Håvard; Fenstad, Anne M; Hallan, Geir

    2012-01-01

    Background and purpose The risk of revision due to infection after primary total hip arthroplasty (THA) has been reported to be increasing in Norway. We investigated whether this increase is a common feature in the Nordic countries (Denmark, Finland, Norway, and Sweden). Materials and methods The...... explain this increase. We believe that there has been an actual increase in the incidence of prosthetic joint infections after THA.......Background and purpose The risk of revision due to infection after primary total hip arthroplasty (THA) has been reported to be increasing in Norway. We investigated whether this increase is a common feature in the Nordic countries (Denmark, Finland, Norway, and Sweden). Materials and methods...... The study was based on the Nordic Arthroplasty Register Association (NARA) dataset. 432,168 primary THAs from 1995 to 2009 were included (Denmark: 83,853, Finland 78,106, Norway 88,455, and Sweden 181,754). Adjusted survival analyses were performed using Cox regression models with revision due to infection...

  18. Reduced survival for uncemented compared to cemented total hip arthroplasty after operatively treated acetabular fractures.

    Science.gov (United States)

    Clarke-Jenssen, John; Westberg, Marianne; Røise, Olav; Storeggen, Stein Arne Øvre; Bere, Tone; Silberg, Ingunn; Madsen, Jan Erik

    2017-11-01

    Post traumatic arthritis and avascular necrosis of the femoral head are common complications after operatively treated acetabular fractures. This may cause severe disabilities for the patient, necessitating a total hip arthroplasty. Even though an arthroplasty may provide good symptomatic relief, the long-term results are more uncertain and no consensus exists according to preferred prosthetic designs. With this cohort study, we aimed to investigate the medium to long term arthroplasty survival and clinical results of total hip arthroplasty after operatively treated acetabular fractures. We included 52 patients treated with a secondary total hip arthroplasty at a median of 2.4 (0.1-14.1) years after an operatively treated acetabular fracture. The median age was 54 (11-82) years. Cemented arthroplasty was used for 33 patients, 10 patients had an uncemented arthroplasty and 9 patients received a hybrid arthroplasty. Average follow up was 8.0 (SD 5.0) years. Ten-year revision free arthroplasty survival was 79%. Uncemented arthroplasties had a significantly worse 10-year survival of 57%. Arthroplasties performed at a centre without a pelvic fracture service also had a significantly worse 10-years survival of 51%. Cox regression showed similar results with an 8-fold increase in risk of revision for both uncemented arthroplasties and operations performed at a non-pelvic trauma centre. Total hip arthroplasty secondary to an operatively treated acetabular fracture provides good symptomatic relief. These patients are, however, complex cases and are probably best treated at specialist centres with both pelvic trauma surgeons and arthroplasty surgeons proficient in complex revisions present. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. A financial analysis of revision hip arthroplasty: the economic burden in relation to the national tariff.

    Science.gov (United States)

    Vanhegan, I S; Malik, A K; Jayakumar, P; Ul Islam, S; Haddad, F S

    2012-05-01

    Revision arthroplasty of the hip is expensive owing to the increased cost of pre-operative investigations, surgical implants and instrumentation, protracted hospital stay and drugs. We compared the costs of performing this surgery for aseptic loosening, dislocation, deep infection and peri-prosthetic fracture. Clinical, demographic and economic data were obtained for 305 consecutive revision total hip replacements in 286 patients performed at a tertiary referral centre between 1999 and 2008. The mean total costs for revision surgery in aseptic cases (n = 194) were £11 897 (sd 4629), for septic revision (n = 76) £21 937 (sd 10 965), for peri-prosthetic fracture (n = 24) £18 185 (sd 9124), and for dislocation (n = 11) £10 893 (sd 5476). Surgery for deep infection and peri-prosthetic fracture was associated with longer operating times, increased blood loss and an increase in complications compared to revisions for aseptic loosening. Total inpatient stay was also significantly longer on average (p < 0.001). Financial costs vary significantly by indication, which is not reflected in current National Health Service tariffs.

  20. Instability after total hip arthroplasty

    Science.gov (United States)

    Werner, Brian C; Brown, Thomas E

    2012-01-01

    Instability following total hip arthroplasty (THA) is an unfortunately frequent and serious problem that requires thorough evaluation and preoperative planning before surgical intervention. Prevention through optimal index surgery is of great importance, as the management of an unstable THA is challenging even for an experienced joints surgeon. However, even after well-planned surgery, a significant incidence of recurrent instability still exists. Non-operative management is often successful if the components are well-fixed and correctly positioned in the absence of neurocognitive disorders. If conservative management fails, surgical options include revision of malpositioned components; exchange of modular components such as the femoral head and acetabular liner; bipolar arthroplasty; tripolar arthroplasty; use of a larger femoral head; use of a constrained liner; soft tissue reinforcement and advancement of the greater trochanter. PMID:22919568

  1. Predictors of revision, prosthetic joint infection and mortality following total hip or total knee arthroplasty in patients with rheumatoid arthritis

    DEFF Research Database (Denmark)

    Cordtz, Rene Lindholm; Zobbe, Kristian; Højgaard, Pil

    2018-01-01

    OBJECTIVES: To investigate predictors of 10-year risk of revision and 1-year risk of prosthetic joint infection (PJI) and death following total hip/total knee arthroplasty (THA/TKA) in (1) patients with rheumatoid arthritis (RA) compared with patients with osteoarthritis (OA); and (2) patients...

  2. USING CUSTOM TRIFLANGE IMPLANT IN REVISION HIP ARTHROPLASTY IN PATIENT WITH PELVIC DISCONTINUITY (CASE REPORT

    Directory of Open Access Journals (Sweden)

    R. M. Tikhilov

    2016-01-01

    Full Text Available Revision hip arthroplasty rate is growing, and pelvic discontinuity rate ranges from 1% to 5% of acetabular component revision reasons. According to AAOS acetabular defects classification, pelvic discontinuity is fourth type defect in which cranial part of hip bone is separated from caudal part at acetabular level. Usually it occurs from bone loss secondary to osteolysis, infection, fracture or aseptic loosening. There are a lot of techniques for pelvis discontinuity treatment. Published results of bulk allografts and antiprotrusion cages have generally been poor. More preferable methods with acceptable rate of good results are cup-cage systems and custom triflange acetabular components(CTAC. CTACs are designed based on preoperative CT scans to build a custom titanium 3D-printed implant to address the patient's specific bone defect and provide secure fixation in the ilium, pubis, and ischium. We faced pelvic discontinuity, in which extensive iliac bone loss was added to caudal hip bone part medial displacement and pelvic ring deformity, in patient with multiple hip surgeries. Preoperative investigation called into question the possibility of using off-the-shelf hip implants, which could restore the biomechanics of the hip and provide reliable primary fixation at the same time. We present case report of the patient with pelvic discontinuity and massive bone loss treatment using a custom triflange component.

  3. Mortality After Total Knee and Total Hip Arthroplasty in a Large Integrated Health Care System.

    Science.gov (United States)

    Inacio, Maria C S; Dillon, Mark T; Miric, Alex; Navarro, Ronald A; Paxton, Elizabeth W

    2017-01-01

    The number of excess deaths associated with elective total joint arthroplasty in the US is not well understood. To evaluate one-year postoperative mortality among patients with elective primary and revision arthroplasty procedures of the hip and knee. A retrospective analysis was conducted of hip and knee arthroplasties performed in 2010. Procedure type, procedure volume, patient age and sex, and mortality were obtained from an institutional total joint replacement registry. An integrated health care system population was the sampling frame for the study subjects and was the reference group for the study. Standardized 1-year mortality ratios (SMRs) and 95% confidence intervals (CIs) were calculated. A total of 10,163 primary total knee arthroplasties (TKAs), 4963 primary total hip arthroplasties (THAs), 606 revision TKAs, and 496 revision THAs were evaluated. Patients undergoing primary THA (SMR = 0.6, 95% CI = 0.4-0.7) and TKA (SMR = 0.4, 95% CI = 0.3-0.5) had lower odds of mortality than expected. Patients with revision TKA had higher-than-expected mortality odds (SMR = 1.8, 95% CI = 1.1-2.5), whereas patients with revision THA (SMR = 0.9, 95% CI = 0.4-1.5) did not have higher-than-expected odds of mortality. Understanding excess mortality after joint surgery allows clinicians to evaluate current practices and to determine whether certain groups are at higher-than-expected mortality risk after surgery.

  4. "Tripolar" hip arthroplasty for failed hip resurfacing: nineteen years follow-up.

    Science.gov (United States)

    Scheerlinck, T; Casteleyn, P P

    2001-10-01

    The authors describe the case of a 37-year-old patient who sustained a subcapital femoral neck fracture six months after ICLH double-cup hip resurfacing. As the polyethylene acetabular resurfacing component was undamaged and well fixed, a standard femoral stem with a bipolar head was inserted. The outer diameter of the bipolar head was chosen to fit the resurfacing socket. The "tripolar" hip arthroplasty has functioned well for 19 years and was revised for aseptic cup loosening. The cemented femoral stem was still well fixed and was not revised. Although the "tripolar" hip has functioned well in our case, we believe it is not indicated for metal on metal bearings. In this case the use of an appropriate modular head with a correct head-socket clearance is preferred.

  5. Lawsuits After Primary and Revision Total Hip Arthroplasties: A Malpractice Claims Analysis.

    Science.gov (United States)

    Patterson, Diana C; Grelsamer, Ronald P; Bronson, Michael J; Moucha, Calin S

    2017-10-01

    As the prevalence of total hip arthroplasty (THA) expands, so too will complications and patient dissatisfaction. The goal of this study was to identify the common etiologies of malpractice suits and costs of claims after primary and revision THAs. Analysis of 115 malpractice claims filed for alleged neglectful primary and revision THA surgeries by orthopedic surgeons insured by a large New York state malpractice carrier between 1983 and 2011. The incidence of malpractice claims filed for negligent THA procedures is only 0.15% per year in our population. In primary cases, nerve injury ("foot drop") was the most frequent allegation with 27 claims. Negligent surgery causing dislocation was alleged in 18 and leg length discrepancy in 14. Medical complications were also reported, including 3 thromboembolic events and 6 deaths. In revision cases, dislocation and infection were the most common source of suits. The average indemnity payment was $386,153 and the largest single settlement was $4.1 million for an arterial injury resulting in amputation after a primary hip replacement. The average litigation cost to the insurer was $61,833. Nerve injury, dislocation, and leg length discrepancy are the most common reason for malpractice after primary THA. Orthopedic surgeons should continue to focus on minimizing the occurrence of these complications while adequately incorporating details about the risks and limitations of surgery into their preoperative education. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Bipolar hip arthroplasty for avascular necrosis of femoral head in young adults

    Directory of Open Access Journals (Sweden)

    Baldev Dudani

    2015-01-01

    Conclusion: Bipolar hip arthroplasty (BHA using tight fitting cup and acetabular reaming in AVN hip has a low incidence of groin pain, acetabular erosion and revision in midterm followup. Good outcome and mid term survival can be achieved irrespective of the Ficat Stage.

  7. Revision Hip Arthroscopy: A Systematic Review of Diagnoses, Operative Findings, and Outcomes.

    Science.gov (United States)

    Cvetanovich, Gregory L; Harris, Joshua D; Erickson, Brandon J; Bach, Bernard R; Bush-Joseph, Charles A; Nho, Shane J

    2015-07-01

    To determine indications for, operative findings of, and outcomes of revision hip arthroscopy. A systematic review was registered with PROSPERO and performed based on PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. Therapeutic clinical outcome studies reporting the indications for, operative findings of, and outcomes of revision hip arthroscopy were eligible for inclusion. All study-, patient-, and hip-specific data were extracted and analyzed. The Modified Coleman Methodology Score was used to assess study quality. Five studies were included (348 revision hip arthroscopies; 333 patients; mean age, 31.4 ± 4.2 years; 60% female patients). All 5 studies were either Level III or IV evidence. The surgeon performing revision hip arthroscopy was the same as the primary hip surgeon in only 25% of cases. The mean time between primary and revision hip arthroscopy was 27.8 ± 7.0 months (range, 2 to 193 months). Residual femoroacetabular impingement was the most common indication for and operative finding of revision hip arthroscopy (81% of cases). The most commonly reported revision procedures were femoral osteochondroplasty (24%) and acetabuloplasty (18%). The modified Harris Hip Score was used in all 5 analyzed studies, with significant (P arthroscopy, subsequent reported operations were hip arthroplasty in 11 patients and re-revision hip arthroscopy in 8 patients (5% total reoperation rate). Revision hip arthroscopy is most commonly performed for residual femoroacetabular impingement, with statistically significant and clinically relevant improvements shown in multiple patient-reported clinical outcome scores at short-term follow-up. The reoperation rate after revision hip arthroscopy is 5% within 2 years, including further arthroscopy or conversion to hip arthroplasty. Level IV, systematic review of Level III and IV studies. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  8. Short-term clinical experience with hip resurfacing arthroplasty.

    Science.gov (United States)

    Cieliński, Łukasz; Kusz, Damian; Wojciechowski, Piotr; Dziuba, Anna

    2007-01-01

    This paper discusses the authors' experience with hip resurfacing arthroplasty. Although introduced many years ago, the method did not gain wide popularity because of poor long-term outcomes. At present, owing to the introduction of metal-on-metal bearings and hybrid fixation techniques, short- and mid-term results are very good and encourage wider use of this technique, especially in the younger and more active patients whose results with standard total hip replacements would be unsatisfactory. We performed 13 hip resurfacing arthroplasties at our institution between August 1, 2005, and May 1, 2006. Twelve patients reported for the scheduled follow-up and were included in the study. Treatment outcomes were assessed according to the Harris Hip Score. The short-term outcomes of hip resurfacing arthroplasties are encouraging. In the study group there were no intraoperative complications, infections, peripheral nerve palsy, hip dislocations or clinically overt vein thrombosis. All of the patients reported complete or major pain relief. Clinical assessment according to the Harris Hip Score revealed improvement from an average of 57.7 (20.1) points preoperatively to an average of 87.7 (12) points after the surgery. Crutches were used for a maximum of 6 weeks postoperatively. All of the patients are currently able to walk without crutches with full weight-bearing. 1) Hip resurfacing arthroplasty seems to be an advisable method of operative management of younger, active patients, in whom standard THR would be associated with a high risk of failure; it allows THR to be postponed and carried out as a revision surgery with the acetabular component already in place. 2) Despite the good short- and mid-term results, the utility of this method should be evaluated with caution due to the lack of adequate long-term follow-up data.

  9. Comparison of total hip arthroplasty in osteoarthritis of mechanical and rheumatologic causes

    Science.gov (United States)

    Ejnisman, Leandro; Leonhardt, Nathalia Zalc; Fernandes, Laura Fillipini Lorimier; Leonhardt, Marcos de Camargo; Vicente, José Ricardo Negreiros; Croci, Alberto Tesconi

    2014-01-01

    Objective: To compare the use of uncemented implants in total hip arthroplasty in patients with rheumathologic diseases and mechanical osteoarthrosis. Methods: We retrospectively evaluated 196 patients who were operated by the Hip and Arthroplasty Surgery Group of the IOT-HCFMUSP between 2005 and 2009. Patients were divided into two groups: mechanical causes (165 patients) and rheumathologic causes (31 patients). Groups were compared between each other in age, gender and follow-up time. Osseointegration rate and percentage of failure in arthroplasty were evaluated. Results: No statistically significant difference was found in osseointegration rates (in both femoral and acetabular components) in both groups. The rates of revision surgery and implant survival also did not show statistically significant differences. Conclusion: The use of uncemented total hip arthroplasty did not show worse results in rheumathologic patients. Level of Evidence III, Retrospective Case Control Study. PMID:24644419

  10. Formation of a pseudotumor in total hip arthroplasty using a tribological metal-polyethylene pair

    Directory of Open Access Journals (Sweden)

    Lorenzo Fagotti

    2015-12-01

    Full Text Available ABSTRACT The aim here was to report a case of a young adult patient who evolved with tumor formation in the left thigh, 14 years after revision surgery on hip arthroplasty. Davies in 2005 made the first description of this disease in patients undergoing metal-on-metal hip arthroplasty. Over the last decade, however, pseudotumors around metal-on-polyethylene surfaces have become more prevalent. Our patient presented with increased volume of the left thigh 8 years after hip arthroplasty revision surgery. Two years before the arising of the tumor in the thigh, a nodule in the inguinal region was investigated to rule out a malignant neoplastic process, but the results were inconclusive. The main preoperative complaints were pain, functional limitation and marked reduction in the range of motion of the left hip. Plain radiographs showed loosening of acetabular and femoral, and a large mass between the muscle planes was revealed through magnetic resonance imaging of the left thigh. The surgical procedure consisted of resection of the lesion and removal of the components through lateral approach. In respect of total hip arthroplasty, pseudotumors are benign neoplasms in which the bearing surface consists of metal-on-metal, but they can also occur in different tribological pairs, as presented in this case.

  11. Imaging of hip arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Theodore T., E-mail: millertt@hss.edu [Department of Radiology and Imaging, Hospital for Special Surgery, 535 E. 70th Street, New York, NY 10021 (United States)

    2012-12-15

    The imaging evaluation of the prosthetic hip begins with radiography, but arthrography, aspiration, scintigraphy, sonography, CT and MR imaging all have roles in the evaluation of the painful prosthesis. This article will review the appearance of normal hip arthroplasty including hemiarthroplasty, total arthroplasty, and hip resurfacing, as well as the appearances of potential complications such as aseptic loosening and osteolysis, dislocation, infection, periprosthetic fracture, hardware failure, and soft tissue abnormalities.

  12. Single-dose radiation therapy for prevention of heterotopic ossification after total hip arthroplasty

    International Nuclear Information System (INIS)

    Healy, W.L.; Lo, T.C.; Covall, D.J.; Pfeifer, B.A.; Wasilewski, S.A.

    1990-01-01

    Single-dose radiation therapy was prospectively evaluated for its efficacy in prevention of heterotopic ossification in patients at high risk after total hip arthroplasty. Thirty-one patients (34 hips) were treated between 1981 and 1988. Risk factors for inclusion in the protocol included prior evidence of heterotopic ossification, ankylosing spondylitis, and diffuse idiopathic skeletal hyperostosis. Patients with hypertrophic osteoarthritis or traumatic arthritis with osteophytes were not included. Operations on 34 hips included 19 primary total and 11 revision total hip arthroplasties and 4 excisions of heterotopic ossification. All patients received radiotherapy to the hip after operation with a single dose of 700 centigray. Radiotherapy is recommended on the first postoperative day. After this single-dose radiation treatment, no patient had clinically significant heterotopic ossification. Recurrent disease developed in two hips (6%), as seen on radiography (grades 2 and 3). This series documents a 100% clinical success rate and a 94% radiographic success rate in preventing heterotopic ossification in patients at high risk after total hip arthroplasty. Single-dose radiotherapy is as effective as other radiation protocols in preventing heterotopic ossification after total hip arthroplasty. It is less expensive and easier to administer than multidose radiotherapy

  13. Association between fixation technique and revision risk in total hip arthroplasty patients younger than 55 years of age. Results from the Nordic Arthroplasty Register Association

    DEFF Research Database (Denmark)

    Pedersen, A. B.; Mehnert, F.; Havelin, L. I.

    2014-01-01

    Objectives: To evaluate implant survival following primary total hip replacement (THR) in younger patients. To describe the diversity in use of cup-stem implant combinations. Design: 29,558 primary THRs osteoarthritis (OA) patients younger than 55 years of age performed from 1995 through 2011 were...... identified using the Nordic Arthroplasty Registry Association database. We estimated adjusted relative risk (aRR) of revision with 95% confidence interval (CI) using Cox regression. Results: In general, no difference was observed between uncemented and cemented implants in terms of risk of any revision...

  14. The use of customized cages in revision total hip arthroplasty for Paprosky type III acetabular bone defects.

    Science.gov (United States)

    Mao, Yuanqing; Xu, Chen; Xu, Jiawei; Li, Huiwu; Liu, Fengxiang; Yu, Degang; Zhu, Zhenan

    2015-10-01

    Revision total hip arthroplasty (THA) is challenging if severe periacetabular bone loss is present. Here we describe a method that uses a customised cage to reconstruct an acetabulum with a massive bone defect. Designed with the aid of the rapid prototyping technique, a customised cage with a hook, crest and flange or braids was made, and then utilized to reconstruct severe compromised acetabulum in revision THA since 2001. Twenty-two patients (23 hips) were included in this study. The mean patient age at the time of surgery was 60.9 years (range, 38-80 years). Three hips had massive acetabular bone defects of Paprosky type IIIA and 20 of type IIIB. The Harris hip score was used to evaluate hip function. Radiographs were taken to evaluate loosening of the cage and resorption of allograft bone. The average follow up was 81.6 ± 24.9 months. The mean Harris hip score improved from 39.6 pre-operatively to 80.9 at the final follow-up. There were no instances of deep infection, severe venous thrombosis, and nerve palsy. One patient who had an intra-operative rupture of the superior acetabular artery was successfully treated using the haemostatic suturing technique. Two patients experienced dislocation at post-operative days four and six, respectively, and both were treated with closed reduction and skin traction for three weeks. The present study demonstrates that a customised cage may be a promising option for THA revision of severely compromised acetabula. Extended follow-up is necessary to evaluate the long-term performance of this approach.

  15. A Large Rice Body-Containing Cyst Mimicking Infection following Total Hip Arthroplasty: A Case Report

    Directory of Open Access Journals (Sweden)

    Wael Bayoud

    2017-01-01

    Full Text Available Introduction. Soft tissue mass following total hip arthroplasty raises several differential diagnoses not limited to infection, hematoma, wear debris, malignancy, and bursitis. Rice body formation in the hip region is an uncommon process denoting a chronic inflammation. We report here the second case of its kind in the medical literature of a wide symptomatic rice-like body cyst complicating a total hip arthroplasty. Case Presentation. This is the case of an 82-year-old white female, presenting with a warm, red, and inflated groin five years after revision of right total hip arthroplasty. Surgical intervention reveals a large well circumscribed cyst containing well-organized rice-like bodies. This eventuality was never reported in differential diagnosis of hip periprosthetic soft tissue masses before. Conclusion. This case report helps widening the array of the differential diagnosis in patients presenting with a slow growing soft tissue mass following total hip arthroplasty, making rice-like bodies cyst a valid one to consider.

  16. No clinical difference between large metal-on-metal total hip arthroplasty and 28-mm-head total hip arthroplasty?

    NARCIS (Netherlands)

    Zijlstra, Wierd P; van den Akker-Scheek, Inge; Zee, Mark J M; van Raay, Jos J A M

    2011-01-01

    PURPOSE: We aimed to test the claim of greater range of motion (ROM) with large femoral head metal-on-metal total hip arthroplasty. METHODS: We compared 28-mm metal-on-polyethylene (MP) total hip arthroplasty with large femoral head metal-on-metal (MM) total hip arthroplasty in a randomised clinical

  17. Cobalt Cardiomyopathy Secondary to Hip Arthroplasty: An Increasingly Prevalent Problem

    Directory of Open Access Journals (Sweden)

    Russel Tilney

    2017-01-01

    Full Text Available A forty-year-old man experienced worsening heart failure four years following bilateral complicated total hip replacement. His condition was extensively worked up but no underlying pathology was immediately evident. Given the cobalt-chromium alloy component present in the hip arthroplasties, the raised cobalt blood levels, and a fitting clinical picture coupled with radiological findings, the patient underwent right hip revision. Evidence of biotribocorrosion was present on direct visualisation intraoperatively. The patient subsequently experienced symptomatic improvement (NYHA class III to class I and echocardiography showed recovery of ejection fraction. Cobalt exists as a bivalent and trivalent molecule in circulation and produces a cytotoxicity profile similar to nanoparticles, causing neurological, thyroid, and cardiological pathology. Blood levels are not entirely useful as there is no identifiable conversion factor for levels in whole blood, serum, and erythrocytes which seem to act independently of each other. Interestingly cobalt cardiomyopathy is frequently compounded by other possible causes of cardiomyopathy such as alcohol and a link has been postulated. Definitive treatment is revision of the arthroplasty as other treatments are unproven.

  18. Increased Resistance of Skin Flora to Antimicrobial Prophylaxis in Patients Undergoing Hip Revision Arthroplasty.

    Science.gov (United States)

    Mühlhofer, Heinrich M L; Deiss, Lukas; Mayer-Kuckuk, Philipp; Pohlig, Florian; Harrasser, Norbert; Lenze, Ulrich; Gollwitzer, Hans; Suren, Christian; Prodinger, Peter; VON Eisenhart-Rothe, Rüdiger; Schauwecker, Johannes

    2017-01-01

    Prosthetic joint infection (PJI) remains a major complication after total joint replacement and is the primary indication for revision arthroplasty. Specifically, coagulase-negative Staphylococci (CNS) can cause low-grade infections. Despite the use of cephalosporin-based antimicrobial prophylaxis (AMP) and antiseptic treatment at the surgical site, evidence suggests that a significant number of cases of dermal CNS results in low-grade PJI. Thus, this study examined the bacterial colonization and resistance patterns at the surgical site. We hypothesized that the bacteria developed resistance to antibiotics that are frequently used in primary and revision total hip arthroplasty (THA) procedures. Ninety patients, including 63 primary and 27 revision THA patients, were enrolled in this study. For each patient, a single swab of the skin at the surgical site was subjected to clinical microbiology to assess bacterial colonization. Furthermore, resistance to a sentinel panel of antibiotics (benzylpenicillin, erythromycin, tetracycline, oxacillin, fusidic acid, clindamycin, gentamicin, levofloxacin/moxifloxacin, rifampicin, linezolid and vancomycin) was tested. In 96.7% of the patients, at least one bacterial strain was identified at the surgical site, with CNS strains comprising 93.1% of the total. The sentinel panel showed that 30.7% of the CNS strains exhibited maximal resistance to oxacillin, a commonly used cephalosporin. Additionally, oxacillin resistance increased 1.9-fold (p=0.042) between primary and revision THA. Notably, 8.1% of the CNS stains found on patients undergoing primary THA were resistant to gentamicin, an aminoglycoside, and this rate increased 4.7-fold (p=0.001) for patients undergoing revision THA. CNS strains have significant resistance to standard AMP, particularly in individuals undergoing revision THA. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  19. Validation of the diagnosis 'prosthetic joint infection' in the Danish Hip Arthroplasty Register

    DEFF Research Database (Denmark)

    Gundtoft, P H; Pedersen, Alma Becic; Schønheyder, H C

    2016-01-01

    and followed them until first-time revision, death, emigration or until 31 December 2012. Revision for PJI, as registered in the DHR, was validated against a benchmark which included information from microbiology databases, prescription registers, clinical biochemistry registers and clinical records. We......AIMS: The purpose of this study was to validate the diagnosis of periprosthetic joint infection (PJI) in the Danish Hip Arthroplasty Register (DHR). PATIENTS AND METHODS: We identified a cohort of patients from the DHR who had undergone primary total hip arthroplasty (THA) since 1 January 2005...... the validity of the diagnosis of PJI and should enable future register-based studies. Cite this article: Bone Joint J 2016;98-B:320-5....

  20. Primary cemented total hip arthroplasty: 10 years follow-up

    Directory of Open Access Journals (Sweden)

    Nath Rajendra

    2010-01-01

    Full Text Available Background: Primary cemented total hip arthroplasty is a procedure for non-traumatic and traumatic affections of the hip. Long term follow-up is required to assess the longevity of the implant and establish the procedure. Indo-Asian literature on long term result of total hip arthroplasty is sparse. We present a 10-year follow-up of our patients of primary cemented total hip arthroplasty. Materials and Methods: We operated 31 hips in 30 patients with primary cemented total hip arthroplasty. We followed the cases for a minimum period of 10 years with a mean follow-up period of 12.7 years. The mean age of the patients was 60.7 years (range 37-82 yrs male to female ratio was 2:1. The clinical diagnoses included - avascular necrosis of femoral head (n=15, sero positive rheumatoid arthritis (n=5, seronegative spondylo-arthropathy (n=4, neglected femoral neck fractures (n=3, healed tubercular arthritis (n=2 and post traumatic osteoarthritis of hip (n=2. The prostheses used were cemented Charnley′s total hip (n=12 and cemented modular prosthesis (n=19. The results were assessed according to Harris hip score and radiographs taken at yearly intervals. Results: The mean follow-up is 12.7 yrs (range 11-16 yrs Results in all operated patients showed marked improvement in Harris hip score from preoperative mean 29.2 to 79.9 at 10 years or more followup. However, the non-inflammatory group showed more sustained long term improvement as compared to the inflammatory group, as revealed by the Harris hip score. Mean blood loss was 450ml (±3.7 ml, mean transfusion rate was 1.2 units (±.3. The complications were hypotension (n=7, shortening> 1.5 cm (n=9, superficial infection (n=2 and malposition of prosthesis (n=1. Conclusion: The needs of Indian Asian patients, vary from what is discussed in literature. The pain tolerance is greater than western population and financial constraints are high. Thus revision surgery among Indian-Asian patients is less compared

  1. Trabecular metal acetabular components in primary total hip arthroplasty

    DEFF Research Database (Denmark)

    Laaksonen, Inari; Lorimer, Michelle; Gromov, Kirill

    2018-01-01

    Background and purpose - Trabecular metal (TM) cups have demonstrated favorable results in acetabular revision and their use in primary total hip arthroplasty (THA) is increasing. Some evidence show that TM cups might decrease periprosthetic infection (PPI) incidence. We compared the survivorship...... of TM cups with that of other uncemented cups in primary THA, and evaluated whether the use of TM cups is associated with a lower risk of PPI. Patients and methods - 10,113 primary THAs with TM cup and 85,596 THAs with other uncemented cups from 2 high-quality national arthroplasty registries were...

  2. Dissociation of modular total hip arthroplasty at the neck-stem interface without dislocation.

    Science.gov (United States)

    Kouzelis, A; Georgiou, C S; Megas, P

    2012-12-01

    Modular femoral and acetabular components are now widely used, but only a few complications related to the modularity itself have been reported. We describe a case of dissociation of the modular total hip arthroplasty (THA) at the femoral neck-stem interface during walking. The possible causes of this dissociation are discussed. Successful treatment was provided with surgical revision and replacement of the modular neck components. Surgeons who use modular components in hip arthroplasties should be aware of possible early complications in which the modularity of the prostheses is the major factor of failure.

  3. Outcomes of Revision Hip Arthroscopy: 2-Year Clinical Follow-up.

    Science.gov (United States)

    Gupta, Asheesh; Redmond, John M; Stake, Christine E; Dunne, Kevin F; Hammarstedt, Jon E; Domb, Benjamin G

    2016-05-01

    To evaluate clinical outcomes, pain, and patient satisfaction following revision hip arthroscopy with a minimum 2-year follow-up. From April 2008 to October 2011, data were prospectively collected on all patients undergoing revision hip arthroscopy. All patients were assessed pre- and postoperatively with 4 patient-reported outcome (PRO) measures: the modified Harris hip score (mHHS), nonarthritic hip score (NAHS), hip outcome score-activities of daily living (HOS-ADL), and hip outcome score-sport-specific subscales (HOS-SSS). Pain was estimated on the visual analog scale (VAS). Patient satisfaction was measured on a scale from 0 to 10. The number of patients who underwent subsequent revision arthroscopy or total hip arthroplasty during the study period is also reported. Eighty-seven patients underwent revision hip arthroscopy during the study period. Seventy (80.5%) patients were included in our study. Average follow-up time was 28 months (range, 20 to 47.4 months). In terms of residual femoroacetabular impingement morphology, 45.7% of patients had preoperative alpha angles ≥ 55°, and 7.14% of patients had a lateral center-edge angle ≥ 40°. The score improvement from preoperative to 2-year follow-up was 57.84 to 73.65 for mHHS, 62.79 to 83.04 for HOS-ADL, 37.33 to 54.93 for HOS-SSS, and 55.65 to 70.79 for NAHS. VAS decreased from 6.72 to 4.08. All scores demonstrated statistically significant improvement (P arthroscopy during the study period. We found an overall minor complication rate of 10%. Revision hip arthroscopy for all procedures performed on aggregate has improved clinical outcomes for all PROs, high survivorship, and high patient satisfaction scores at short-term follow-up. Patients should be counseled regarding the potential progression of degenerative change leading to arthroplasty and the potential for revision surgery. Level IV retrospective case series. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc

  4. Cardiac transplant due to metal toxicity associated with hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Sheldon Moniz, MBBS (UWA

    2017-09-01

    Full Text Available Concerns regarding metal-on-metal (MoM bearing couples in total hip arthroplasty are well documented in the literature with cobalt (Co and chromium (Cr toxicity causing a range of both local and systemic adverse reactions. We describe the case of a patient undergoing cardiac transplantation as a direct result of Co and Cr toxicity following a MoM hip replacement. Poor implant positioning led to catastrophic wear generating abundant wear particles leading to Co and Cr toxicity, metallosis, bony destruction, elevated metal ion levels, and adverse biological responses. Systemic symptoms continued for 3 years following cardiac transplantation with resolution only after revision hip arthroplasty. There was no realization in the initial cardiac assessment and subsequent transplant workup that the hip replacement was the likely cause of the cardiac failure, and the hip replacement was not recognized as the cause until years after the heart transplant. This case highlights the need for clinicians to be aware of systemic MoM complications as well as the importance of positioning when using these prostheses.

  5. [Poldi-Čech cemented femoral stem in total hip arthroplasty after 25 years].

    Science.gov (United States)

    Rozkydal, Z; Janíček, P

    2010-08-01

    The aim of the study was to evaluate the results of Poldi-Čech femoral stem implantation in primary total hip arthroplasty after 25 years. A group of 65 patients (90 hips) with Poldi-Čech total hip arthroplasty carried out between 1974 and 1984 was evaluated at the end of 2009. The mean follow-up of all patients was 28 years (25 to 35). There were seven men and 58 women. The mean age at the time of implantation was 43 years (26 to 60) and at the latest follow-up it was 72 years. In all patients the cemented UHMW PE acetabular component (RCH 1000) was used together with AKV Ultra 2 Poldi steel femoral stems (1st, 2nd and 3rd generations). The stem was a monoblock with a 32-mm head. The evaluation of the results was based on the Harris hip score and X ray with an A-P view of the pelvis and the affected hip. Statistical analysis was made using the life-table method. At the latest follow up the mean Harris score was 69.7 points (40 to 88). There were 69 hips with an original Poldi-Čech femoral component still in situ, 64 of them were stable and five with radiological evidence of aseptic loosening. Five patients had undergone Girdlestone resection arthroplasty for septic loosening. Thirteen patients (16 hips) had femoral stem revision. The cumulative proportion of clinical survivorship of the Poldi-Čech femoral stem, with revision for any reason as the endpoint, .was 0.93 at 6 years, 0.84 at 12 years, and 0.77 at 18, 24 and 30 years after the index surgery. Radiographic findings revealed 64 hips with stable stems, five hips with ;aseptic loosening (probable, 0 possible, 2, definite, 3). Six- teen hips were after revision surgery for aseptic loosening of the stem and five hips were after Girdlestone resection arthroplasty for septic failure. The cumulative proportion of radiological survivorship of the Poldi-Čech femoral stem with any reason as the endpoint was 0.92 at 6 years, 0.78 at 12 years, 0.72 at 18 years, 0.69 at 24 years and 0.69 at 30 years. The Poldi

  6. Total hip arthroplasty in Denmark

    DEFF Research Database (Denmark)

    Pedersen, Alma Becic; Johnsen, Søren Paaske; Overgaard, Søren

    2005-01-01

    The annual number of total hip arthroplasties (THA) has increased in Denmark over the past 15 years. There is, however, limited detailed data available on the incidence of THAs.......The annual number of total hip arthroplasties (THA) has increased in Denmark over the past 15 years. There is, however, limited detailed data available on the incidence of THAs....

  7. Hip Resurfacing Arthroplasty and Perioperative Blood Testing

    Directory of Open Access Journals (Sweden)

    Andrew Cook

    2014-01-01

    Full Text Available It is standard practice in many institutions to routinely perform preoperative and postoperative haemoglobin level testing in association with hip joint arthroplasty procedures. It is our observation, however, that blood transfusion after uncomplicated primary hip arthroplasty in healthy patients is uncommon and that the decision to proceed with blood transfusion is typically made on clinical grounds. We therefore question the necessity and clinical value of routine perioperative blood testing about the time of hip resurfacing arthroplasty. We present analysis of perioperative blood tests and transfusion rates in 107 patients undertaking unilateral hybrid hip resurfacing arthroplasty by the senior author at a single institution over a three-year period. We conclude that routine perioperative testing of haemoglobin levels for hip resurfacing arthroplasty procedures does not assist in clinical management. We recommend that postoperative blood testing only be considered should the patient demonstrate clinical signs of symptomatic anaemia or if particular clinical circumstances necessitate.

  8. Outcomes of cup revision for ilio-psoas impingement after total hip arthroplasty: Retrospective study of 46 patients.

    Science.gov (United States)

    Batailler, C; Bonin, N; M Wettstein; Nogier, A; Martres, S; Ollier, E; May, O; Lustig, S

    2017-12-01

    Impingement of the ilio-psoas tendon on the acetabular component is a cause of pain after total hip arthroplasty (THA). Studies of cup revision for ilio-psoas impingement (IPI) are scarce and limited in size. We therefore conducted a large multicentre retrospective study with the following objectives: to assess the effectiveness of cup replacement in resolving the impingement syndrome, to determine the frequency and nature of complications after cup revision for IPI, and to identify pre-operative factors associated with good outcomes of cup revision for IPI. Cup revision is effective in resolving the pain due to IPI in selected patients. This retrospective multicentre study included 46 patients who underwent cup revision because of IPI. Before the revision, 38 (83%) patients had prominence of the anterior cup rim (mean, 9.9±4.5mm (range, 2-22mm) by radiography and 35 (76%) had cup malposition (anteversion50°). Mean follow-up was 21months (range, 6months to 6 years) and no patient was lost to follow-up. Outcomes at last follow-up were assessed based on the Oxford Hip Score (OHS), patient satisfaction index, complications, and revisions. At last follow-up, 39 (85%) patients were satisfied with the revision procedure, a significant improvement versus baseline was noted in the OHS (mean, 43±6; range, 25-48; P<0.001), and 41 patients were free of pain during hip flexion (P<0.001 versus baseline). Complications occurred in 3 (6.5%) patients, but only one complication was severe (deep infection). Recurrent groin pain was reported by 4 (8.7%) patients at last follow-up. None of the factors studied predicted the outcome of revision surgery. Cup revision for IPI after THA is effective in relieving the groin pain in 80% of patients with anterior cup rim prominence and/or cup malposition. However, complications can occur. Tenotomy may be preferable when the diagnosis is in doubt and/or cup position is acceptable. IV, retrospective observational study. Published by Elsevier

  9. Hip arthroplasty in failed intertrochanteric fractures in elderly

    Directory of Open Access Journals (Sweden)

    Javahir A Pachore

    2013-01-01

    Full Text Available Background: Failed intertrochanteric fractures in elderly patients are surgical challenge with limited options. Hip arthroplasty is a good salvage procedure even though it involves technical issues such as implant removal, bone loss, poor bone quality, trochanteric nonunion and difficulty of surgical exposure. Materials and Methods: 30 patients of failed intertrochanteric fractures where hip arthroplasty was done between May 2008 and December 2011 were included in study. 13 were males and 17 were females with average age of 67.3 years. There were 2 cemented bipolar arthroplasties, 19 uncemented bipolar, 4 cemented total hip arthroplasty and 5 uncemented total hip arthroplasties. 16 patients had a trochanteric nonunion, which was treated by tension band principles. Total hip was considered where there was acetabular damage due to the penetration of implant. Results: The average followup was 20 months (range 6-48 months. Patients were followed up from 6 to 48 months with average followup of 20 months. None of the patients were lost to followup. There was no dislocation. All patients were ambulatory at the final followup. Conclusion: A predictable functional outcome can be achieved by hip arthroplasty in elderly patients with failed intertrochanteric fractures. Though technically demanding, properly performed hip arthroplasty can be a good salvage option for this patient group.

  10. The Role of Hip Arthroscopy in Investigating and Managing the Painful Hip Resurfacing Arthroplasty.

    Science.gov (United States)

    Mei-Dan, Omer; Pascual-Garrido, Cecilia; Moreira, Brett; McConkey, Mark O; Young, David A

    2016-03-01

    To determine the safety and efficacy of hip arthroscopy performed in the peripheral compartment as a diagnostic and therapeutic treatment option for patients with hip pain after hip resurfacing surgery. Indications for hip arthroscopy after hip resurfacing included patients with a symptomatic hip-resurfaced arthroplasties who did not respond to nonoperative treatment. Patients who underwent a hip arthroscopy after a painful hip resurfacing were included with a minimum of 1 year follow-up. Subgroup analysis was performed according to whether an established diagnosis was made before arthroscopic intervention or not. Subjective measures were based on Western Ontario and McMaster Universities Arthritis Index (WOMAC) scores, and results were calculated and analyzed. We included 68 patients (26 male [38%] and 42 female [62%]) who underwent subsequent hip arthroscopy from a population of 978 consecutive hip-resurfaced arthroplasties performed between 1999 and 2010. The average age was 58 (range, 37 to 78 years). The mean follow-up after hip arthroscopy was 3.4 years (range, 12 months to 5.8 years). Patients who had an established diagnosis (n = 41) before hip arthroscopy showed statistical improvement in their WOMAC scores (7 to 2, P arthroscopy showed statistical worsening of the WOMAC (15 to 21, P = .002). Ten (37%) of these 27 patients without a diagnosis failed and needed to be converted to a THR. A significant correlation was found between the collections found on ultrasound (psoas bursa and/or in the hip joint) and the need for synovectomy (P = .01). The overall revision rate to THR after hip resurfacing in our group of patients was 1.3% (n = 13). Female patients were more likely to require postresurfacing hip arthroscopy with 42 (60%) female to only 26 (40%) male patients undergoing this procedure. In our study population, 70% (14/21, P arthroscopy. Hip arthroscopy is a safe surgical treatment option for those patients with a painful hip resurfacing

  11. The Use of a Supra-Acetabular Antibiotic-Loaded Cement Shelf to Improve Hip Stability in First-Stage Infected Total Hip Arthroplasty.

    Science.gov (United States)

    Drexler, Michael; Kuzyk, Paul R T; Koo, Kevin; Gross, Allan E; Kosashvili, Yona; Reischl, Nickola; Rutenberg, Tal Frenkel; Safir, Oleg

    2016-11-01

    Antibiotic-loaded cement spacers in first-stage revision total hip arthroplasty (THA) for managing infection are associated with high dislocation and fracture rates. The aim of this study was to report the use of an antibiotic-loaded cemented supra-acetabular roof augmentation to reinforce hip stability after cement spacer insertion for first-stage total hip revision in the treatment of infected THA. We retrospectively reviewed a consecutive series of 50 THAs involving 47 patients with an infected hip requiring staged revisions of THA. We documented dislocation, reinfection, and time for revision and outcome. There were no cases of hip dislocation, cement fractures, or any other technical complications associated with the use of the roof augmentation lip. Thirteen cases (26%) had a cemented spacer for longer than 120 days. Seven (14%) cases had recurrent infection after staged revision THA. The antibiotic-loaded cemented supra-acetabular roof augment improved femoral head spacer coverage for patients requiring a staged revision THA for infection. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Two-Stage Progressive Femoral Lowering Followed by Cementless Total Hip Arthroplasty for Treating Crowe IV-Hartofilakidis Type 3 Developmental Dysplasia of the Hip.

    Science.gov (United States)

    Binazzi, Roberto

    2015-05-01

    High developmental dysplasia of the hip is commonly treated with total hip arthroplasty and shortening osteotomy. We present a two stage technique, consisting of progressive femoral lowering followed by total hip arthroplasty. The clinico-radiographic results of eleven patients (twelve hips) who were operated on with the two-stage technique were evaluated at a mean follow-up of 11 ± 5 years. At the final follow-up, ten patients (eleven hips) had a mean Harris hip score of 85 ± 5 points with no implant loosening. One patient (one hip) was revised at 5 years due to infection. No neurovascular complications were observed in any patients. With this technique, we could place the cup in the anatomical position and obtain complete limb symmetry with excellent clinical results at long-term. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Digital versus analogue preoperative planning of total hip arthroplasties - A randomized clinical trial of 210 total hip arthroplasties

    NARCIS (Netherlands)

    The, Bertram; Verdonschot, Nico; van Horn, Jim R.; van Ooijen, Peter M. A.; Diercks, Ron L.

    The objective of this randomized clinical trial was to compare the clinical and technical results of digital preoperative planning for primary total hip arthroplasties with analogue planning. Two hundred and ten total hip arthroplasties were randomized. All plans were constructed on standardized

  14. One-stage revision of infected hip arthroplasty: outcome of 39 consecutive hips.

    Science.gov (United States)

    Ilchmann, Thomas; Zimmerli, Werner; Ochsner, Peter Emil; Kessler, Bernhard; Zwicky, Lukas; Graber, Peter; Clauss, Martin

    2016-05-01

    There are various options for treating periprosthetic joint infection (PJI). Two-stage exchange has traditionally been the gold standard. However, if the appropriate surgical intervention is chosen according to a rational algorithm, the outcome is similar when using all types of interventions. In an observational cohort study, the outcome of patients with PJI after hip replacement treated with one-stage revision was analysed. All patients fulfilling all criteria for one-stage exchange according to the Infectious Diseases Society of America (IDSA) guidelines and six without preoperative identification of a microorganism were included. Implant removal, debridement and cemented or uncemented reimplantations were performed in a single intervention. If a cemented device was implanted, commercially available gentamicin cement was used in all cases. Antibiotic treatment was administered intravenously for at least 2 weeks, followed by oral therapy for a total duration of 3 months. Patients had standardised clinical and radiological follow-up visits. Between 1996 and 2011, 38 patients (39 hips) were treated with a one-stage procedure and followed for at least 2 years. Coagulase-negative staphylococci were the most frequent pathogens, and polymicrobial infection was observed in five cases. In 25 hips, an uncemented revision stem was implanted, and 37 hips received an acetabular reinforcement ring. The mean follow-up was 6.6 (2.0-15.1) years. No patient had persistent, recurrent or new infection. There were four stem revisions for aseptic loosening. The mean Harris Hip Score was 81 points (26-99) at the final follow-up. Excellent cure rate and function seen in our study suggest that one-stage exchange is a safe procedure, even without local antibiotic treatment, provided that the patient has no sinus tract or severe soft tissue damage, no major bone grafting is required and the microorganism is susceptible to orally administered agents with high bioavailability.

  15. Comparison of dual mobility cup and other surgical construts used for three hundred and sixty two first time hip revisions due to recurrent dislocations: five year results from Lithuanian arthroplasty register.

    Science.gov (United States)

    Stucinskas, Justinas; Kalvaitis, Tomas; Smailys, Alfredas; Robertsson, Otto; Tarasevicius, Sarunas

    2018-05-01

    Recently, there has been increasing interest in the use of dual mobility systems in the treatment of hip instability. The aim of this study was to investigate the re-revision rate of dual mobility cup compared to different surgical concepts when used for first-time hip revisions due to recurrent dislocations. The data were derived from the Lithuanian Arthroplasty Register. For survival analysis, we used both re-revision for all reasons and for dislocations as an end-point. Cox proportional hazards models were used to analyze the influence of various covariates (age, gender, and implant concept). A total of 1388 revisions were recorded from 2011 to 2015, of which 362 were performed due to recurrent dislocation. Of the revisions, 247 were performed using dual mobility cups, while 115 were performed using a variety of other surgical constructs including constrained acetabular cups, conventional cups, femoral head exchanges, stem exchanges or anti-luxation rings. There were 27 re-revisions of which 15 were for additional dislocations. There were only 2% re-revisions due to dislocation with dual mobility vs 9% when using other surgical constructs. Cox regression adjusting for age and gender showed that in the short-term, dual mobility cup had a lower risk of revision due to dislocation as well as for all reasons compared to the other surgical constructs. In revision of total hip arthroplasties for dislocation, significantly lower short-term re-revision rate was observed for patients revised with dual mobility cup.

  16. The Cost-Effectiveness of Dual Mobility Implants for Primary Total Hip Arthroplasty: A Computer-Based Cost-Utility Model.

    Science.gov (United States)

    Barlow, Brian T; McLawhorn, Alexander S; Westrich, Geoffrey H

    2017-05-03

    Dislocation remains a clinically important problem following primary total hip arthroplasty, and it is a common reason for revision total hip arthroplasty. Dual mobility (DM) implants decrease the risk of dislocation but can be more expensive than conventional implants and have idiosyncratic failure mechanisms. The purpose of this study was to investigate the cost-effectiveness of DM implants compared with conventional bearings for primary total hip arthroplasty. Markov model analysis was conducted from the societal perspective with use of direct and indirect costs. Costs, expressed in 2013 U.S. dollars, were derived from the literature, the National Inpatient Sample, and the Centers for Medicare & Medicaid Services. Effectiveness was expressed in quality-adjusted life years (QALYs). The model was populated with health state utilities and state transition probabilities derived from previously published literature. The analysis was performed for a patient's lifetime, and costs and effectiveness were discounted at 3% annually. The principal outcome was the incremental cost-effectiveness ratio (ICER), with a willingness-to-pay threshold of $100,000/QALY. Sensitivity analyses were performed to explore relevant uncertainty. In the base case, DM total hip arthroplasty showed absolute dominance over conventional total hip arthroplasty, with lower accrued costs ($39,008 versus $40,031 U.S. dollars) and higher accrued utility (13.18 versus 13.13 QALYs) indicating cost-savings. DM total hip arthroplasty ceased being cost-saving when its implant costs exceeded those of conventional total hip arthroplasty by $1,023, and the cost-effectiveness threshold for DM implants was $5,287 greater than that for conventional implants. DM was not cost-effective when the annualized incremental probability of revision from any unforeseen failure mechanism or mechanisms exceeded 0.29%. The probability of intraprosthetic dislocation exerted the most influence on model results. This model

  17. Kaplan-Meier Survival Analysis Overestimates the Risk of Revision Arthroplasty: A Meta-analysis.

    Science.gov (United States)

    Lacny, Sarah; Wilson, Todd; Clement, Fiona; Roberts, Derek J; Faris, Peter D; Ghali, William A; Marshall, Deborah A

    2015-11-01

    Although Kaplan-Meier survival analysis is commonly used to estimate the cumulative incidence of revision after joint arthroplasty, it theoretically overestimates the risk of revision in the presence of competing risks (such as death). Because the magnitude of overestimation is not well documented, the potential associated impact on clinical and policy decision-making remains unknown. We performed a meta-analysis to answer the following questions: (1) To what extent does the Kaplan-Meier method overestimate the cumulative incidence of revision after joint replacement compared with alternative competing-risks methods? (2) Is the extent of overestimation influenced by followup time or rate of competing risks? We searched Ovid MEDLINE, EMBASE, BIOSIS Previews, and Web of Science (1946, 1980, 1980, and 1899, respectively, to October 26, 2013) and included article bibliographies for studies comparing estimated cumulative incidence of revision after hip or knee arthroplasty obtained using both Kaplan-Meier and competing-risks methods. We excluded conference abstracts, unpublished studies, or studies using simulated data sets. Two reviewers independently extracted data and evaluated the quality of reporting of the included studies. Among 1160 abstracts identified, six studies were included in our meta-analysis. The principal reason for the steep attrition (1160 to six) was that the initial search was for studies in any clinical area that compared the cumulative incidence estimated using the Kaplan-Meier versus competing-risks methods for any event (not just the cumulative incidence of hip or knee revision); we did this to minimize the likelihood of missing any relevant studies. We calculated risk ratios (RRs) comparing the cumulative incidence estimated using the Kaplan-Meier method with the competing-risks method for each study and used DerSimonian and Laird random effects models to pool these RRs. Heterogeneity was explored using stratified meta-analyses and

  18. CT and MRI of hip arthroplasty

    International Nuclear Information System (INIS)

    Cahir, J.G.; Toms, A.P.; Marshall, T.J.; Wimhurst, J.; Nolan, J.

    2007-01-01

    Plain films are the initial imaging method of choice for evaluation of hip arthroplasty. Recent advances in technology and imaging techniques have largely overcome the problems of beam hardening in computed tomography (CT) and magnetic susceptibility artefact in magnetic resonance imaging (MRI). CT and MRI have now become useful imaging techniques in the assessment of hip arthroplasty

  19. Physical activity of elderly patients after total hip arthroplasty.

    Science.gov (United States)

    Cukras, Zbigniew; Praczko, Katarzyna; Kostka, Tomasz; Jegier, Anna

    2007-01-01

    Total hip arthroplasty (THA) is the most common method of treatment of severe hip osteoarthritis. There is little data concerning the physical activity of total hip arthroplasty patients in Poland and investigations to explore this area are useful. The aim of the study was to describe the post-operative physical activity of total hip arthroplasty patients. A total of 146 adult people were examined, among which 28 men and 41 women had undergone total hip arthroplasty due to primary osteoarthritis of the hip, while another 32 men and 41 women matched for age who had not undergone hip surgery for osteoarthritis served as controls. The physical activity of study participants was assessed with the 7-Day Physical Activity Recall Questionnaire. All participants were also asked about the type and amount of physical activity they engaged in to maintain good health. Physical activity measured as the total amount of calories expended through physical activity per week was similar in the post-THA patients compared to the controls. The only differences were a smaller amount of calories expended during low-intensity physical activity by men after total hip arthroplasty compared to men who had not undergone surgery for osteoarthritis and a smaller amount of calories expended through high-intensity physical activity by women after total hip arthroplasty compared to female controls. The kinds of recreational physical activity most commonly practised by patients a mean of two years after total hip arthroplasty were marching, bicycling and general body conditioning exercises (usually the continuation of exercises recommended during post-operative rehabilitation). The percentage of post-THA patients undertaking physical activity for the prevention of non-communicable diseases was low. Physical activity should be more effectively encouraged in patients after total hip arthroplasty.

  20. Imaging of hip joint arthroplasty

    International Nuclear Information System (INIS)

    Mayerhoefer, M.E.; Fruehwald-Pallamar, J.; Czerny, C.

    2009-01-01

    The hip joint is the largest joint in the human body and consequently, its evaluation by diagnostic imaging is highly important. This includes imaging of hip joint arthroplasty, which is used to avoid joint immobility following a wide spectrum of diseases, such as end-stage degenerative disease, avascular necrosis of the femoral head or post-traumatic fractures. Conventional radiography is still the standard imaging modality for the evaluation of hip arthroplasty both directly following surgery and for periodical follow-up. In the majority of cases conventional radiography enables adequate assessment of early and late complications that can arise following hip arthroplasty, such as loosening, prosthetic or periprosthetic fracture, luxation, infection and soft tissue calcification. If the diagnosis cannot be established by means of radiography, advanced imaging methods such as computed tomography (CT) and magnetic resonance imaging (MRI), with or without injection of contrast media, may provide additional information. This is particularly true for the depiction of inflammatory processes. Regardless of the imaging modality used patients' clinical symptoms must also be taken into account in order to establish the correct diagnosis. (orig.) [de

  1. Metal-on-Metal Total Hip Resurfacing Arthroplasty

    Science.gov (United States)

    2006-01-01

    Executive Summary Objective The objective of this review was to assess the safety and effectiveness of metal on metal (MOM) hip resurfacing arthroplasty for young patients compared with that of total hip replacement (THR) in the same population. Clinical Need Total hip replacement has proved to be very effective for late middle-aged and elderly patients with severe degenerative diseases of the hips. As indications for THR began to include younger patients and those with a more active life style, the longevity of the implant became a concern. Evidence suggests that these patients experience relatively higher rates of early implant failure and the need for revision. The Swedish hip registry, for example, has demonstrated a survival rate in excess of 80% at 20 years for those aged over 65 years, whereas this figure was 33% by 16 years in those aged under 55 years. Hip resurfacing arthroplasty is a bone-conserving alternative to THR that restores normal joint biomechanics and load transfer. The technique has been used around the world for more than 10 years, specifically in the United Kingdom and other European countries. The Technology Metal-on-metal hip resurfacing arthroplasty is an alternative procedure to conventional THR in younger patients. Hip resurfacing arthroplasty is less invasive than THR and addresses the problem of preserving femoral bone stock at the initial operation. This means that future hip revisions are possible with THR if the initial MOM arthroplasty becomes less effective with time in these younger patients. The procedure involves the removal and replacement of the surface of the femoral head with a hollow metal hemisphere, which fits into a metal acetabular cup. Hip resurfacing arthroplasty is a technically more demanding procedure than is conventional THR. In hip resurfacing, the femoral head is retained, which makes it much more difficult to access the acetabular cup. However, hip resurfacing arthroplasty has several advantages over a

  2. Simultaneous and staged bilateral total hip arthroplasty

    DEFF Research Database (Denmark)

    Lindberg-Larsen, Martin; Joergensen, Christoffer Calov; Husted, Henrik

    2013-01-01

    Bilateral total hip arthroplasty (BTHA) and bilateral simultaneous total hip arthroplasty (BSTHA) are done increasingly. Previous studies evaluating outcomes after bilateral procedures have found different results. The aim of this study was to investigate length of hospital stay (LOS), 30 days...

  3. Failure of aseptic revision total knee arthroplasties.

    Science.gov (United States)

    Leta, Tesfaye H; Lygre, Stein Håkon L; Skredderstuen, Arne; Hallan, Geir; Furnes, Ove

    2015-02-01

    In Norway, the proportion of revision knee arthroplasties increased from 6.9% in 1994 to 8.5% in 2011. However, there is limited information on the epidemiology and causes of subsequent failure of revision knee arthroplasty. We therefore studied survival rate and determined the modes of failure of aseptic revision total knee arthroplasties. This study was based on 1,016 aseptic revision total knee arthroplasties reported to the Norwegian Arthroplasty Register between 1994 and 2011. Revisions done for infections were not included. Kaplan-Meier and Cox regression analyses were used to assess the survival rate and the relative risk of re-revision with all causes of re-revision as endpoint. 145 knees failed after revision total knee arthroplasty. Deep infection was the most frequent cause of re-revision (28%), followed by instability (26%), loose tibial component (17%), and pain (10%). The cumulative survival rate for revision total knee arthroplasties was 85% at 5 years, 78% at 10 years, and 71% at 15 years. Revision total knee arthroplasties with exchange of the femoral or tibial component exclusively had a higher risk of re-revision (RR = 1.7) than those with exchange of the whole prosthesis. The risk of re-revision was higher for men (RR = 2.0) and for patients aged less than 60 years (RR = 1.6). In terms of implant survival, revision of the whole implant was better than revision of 1 component only. Young age and male sex were risk factors for re-revision. Deep infection was the most frequent cause of failure of revision of aseptic total knee arthroplasties.

  4. Outcomes and prognostic factors in revision hip arthroplasty for severe intra-pelvic cup protrusion: 246 cases.

    Science.gov (United States)

    Epinette, J-A; Mertl, P; Combourieu, B; Goncalves, H; Blairon, A; Ehlinger, M; Tabutin, J

    2015-10-01

    The outcome of revision total hip arthroplasty (THA) for intra-pelvic cup protrusion is unclear. Hence, we conducted a large retrospective study to clarify the surgical strategy (hip lever arm and cup mechanical fixation) and the outcomes of reconstruction for severe intra-pelvic cup protrusion. We hypothesized that restoration of the anatomic hip centre in such acetabular revisions decreased the risk of recurrent loosening. The study included 246 THA procedures (in 220 patients), with a follow-up of 5.2 ± 4.9 years (1-24.2) after the index surgery. Bone loss was estimated using the SOFCOT classification (grade III or IV in 80% of cases) and the Paprosky classification (IIIA or IIIB in 58% of cases). Quality of the reconstruction was assessed on X-rays according to the correction of the protrusion and position of the hip centre of rotation. After a clinical follow-up of at least 5 years, with a mean of 9.9 ± 4.1 years (5-24 years), the mean Postel-Merle d'Aubigné score was 14.2 ± 3.1 and the mean Harris Hip Score was 78.0 ± 18.7. Cup protrusion was partially or completely corrected in every case and cup position was normal in 27 (11%) cases. The centre of rotation was within 10mm of the physiological position in 158 (64.2%) cases, acceptable in 77 (31.3%) cases, ascended in 9 (3.7%) cases, and worsened in 1 (0.4%) case. Revision for cup or cup and femoral failures was required in 24 (9.8%) cases. Cumulative survival rates with cup loosening as the endpoint were 88.5% after 5 years, 79.9% after 10 years, and 63.9% at last follow-up at 13.6 years. Our hypothesis that restoration of anatomic hip centre decreased the risk of recurrent loosening was not verified: success or failure in restoring the normal centre of rotation did not correlate significantly with final cup status. Recurrent aseptic loosening was the cause of failure in 9.8% of cases. Ensuring long-term effective mechanical stability had a greater impact on global outcomes than restoring an ideal

  5. [Total hip endoprosthesis following resection arthroplasty].

    Science.gov (United States)

    Engelbrecht, E; Siegel, A; Kappus, M

    1995-08-01

    From 1976 to December 1994, a total of 347 patients underwent implantation of a hip prosthesis at the ENDO-Klinik for treatment of an unsatisfactory condition following resection arthroplasty. From 1976 to 1987, 143 patients were treated and in 1989 the results obtained in these patients were analysed: 99 of them were available for a follow-up examination in 1989, and 64 for a further examination in 1995. In 130 cases infection had been the reason for joint resection. At the time of the prosthesis operation (1-20 years later) intraoperative biopsy revealed that infection was still present in 41 cases (31.5%). Only 15 of these infections had been detected preoperatively by joint aspiration. This shows that the value of resection arthroplasty as a method of treating periprosthetic infection is limited and lends support to the one-stage exchange operation, which is the method we prefer in cases of infected hip prostheses. The operative technique and preparation for implantation of the prosthesis are described, as are septic and aseptic complications and the measures that can be taken to treat them. In spite of the patients' generally poor initial condition and with due consideration for the further revision operations, the medium-term results finally obtained are poor in only 9%.

  6. Delayed cementless total hip arthroplasty for neglected dislocation of hip combined with complex acetabular fracture and deficient bone stock

    Directory of Open Access Journals (Sweden)

    Gavaskar Ashok S

    2012-12-01

    Full Text Available 【Abstract】Total hip arthroplasty (THA for an un-treated acetabular fracture is technically challenging and the long-term result is not so favorable. A 45-year-old fe-male patient with untreated column and comminuted poste-rior wall fracture of the acetabulum was treated in our insti-tution by reconstruction of the posterior wall using iliac strut autograft and plate stabilization of the posterior col-umn with cancellous grafting and cementless THA in a single stage. At 3 years’ follow-up, the patient was independently mobile without limb length discrepancy. Radiological evalu-ation showed well integrated components and bone grafts. No evidence of aseptic loosening or osteolysis was found. This report aims to emphasize that bony acetabular recon-struction allows the use of primary hip components, which improves prosthesis longevity and preserves bone stock for a future revision. Key words: Acetabulum; Fractures, bone; Hip dislocation; Arthroplasty, replacement, hip

  7. Reverse-total shoulder arthroplasty cost-effectiveness: A quality-adjusted life years comparison with total hip arthroplasty.

    Science.gov (United States)

    Bachman, Daniel; Nyland, John; Krupp, Ryan

    2016-02-18

    To compare reverse-total shoulder arthroplasty (RSA) cost-effectiveness with total hip arthroplasty cost-effectiveness. This study used a stochastic model and decision-making algorithm to compare the cost-effectiveness of RSA and total hip arthroplasty. Fifteen patients underwent pre-operative, and 3, 6, and 12 mo post-operative clinical examinations and Short Form-36 Health Survey completion. Short form-36 Health Survey subscale scores were converted to EuroQual Group Five Dimension Health Outcome scores and compared with historical data from age-matched patients who had undergone total hip arthroplasty. Quality-adjusted life year (QALY) improvements based on life expectancies were calculated. The cost/QALY was $3900 for total hip arthroplasty and $11100 for RSA. After adjusting the model to only include shoulder-specific physical function subscale items, the RSA QALY improved to 2.8 years, and its cost/QALY decreased to $8100. Based on industry accepted standards, cost/QALY estimates supported both RSA and total hip arthroplasty cost-effectiveness. Although total hip arthroplasty remains the quality of life improvement "gold standard" among arthroplasty procedures, cost/QALY estimates identified in this study support the growing use of RSA to improve patient quality of life.

  8. Comparison of hip function and quality of life of total hip arthroplasty and resurfacing arthroplasty in the treatment of young patients with arthritis of the hip joint at 5 years.

    Science.gov (United States)

    Costa, Matthew L; Achten, Juul; Foguet, Pedro; Parsons, Nicholas R

    2018-03-12

    To compare the medium-term clinical effectiveness of total hip arthroplasty and resurfacing arthroplasty. Single centre, two-arm, parallel group, assessor blinded, randomised controlled trial with 1:1 treatment allocation. A large teaching hospital in England. 122 patients older than 18 years with severe arthritis of the hip joint, suitable for resurfacing arthroplasty of the hip. Patients were excluded if they were considered to be unable to adhere to trial procedures or complete questionnaires. Total hip arthroplasty (replacement of entire femoral head and neck); hip resurfacing arthroplasty (replacement of the articular surface of femoral head only, femoral neck remains intact). Both procedures replaced the articular surface of the acetabulum. The outcome measures were hip function assessed using the Oxford Hip Score (OHS) and health-related quality of life assessed using the EuroQol (EQ-5D). Patients were followed up annually for a minimum of 5 years. Outcome data were modelled using the generalised estimating equation methodology to explore temporal variations during follow-up. 60 patients were randomly assigned to hip resurfacing arthroplasty and 62 to total hip arthroplasty. 95 (78%) of the 122 original study participants provided data at 5 years. There was a small decrease in both hip functions and quality of life in both groups of patients each year during the 5-year follow-up period. However, there was no evidence of a significant difference between treatments group in the OHS (P=0.333) or the EQ-5D (P=0.501). We previously reported no difference in outcome in the first year after surgery. The current medium-term results also show no evidence of a difference in hip function or health-related quality of life in the 5 years following a total hip arthroplasty versus resurfacing arthroplasty. ISRCTN33354155. UKCRN 4093. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use

  9. Clinical Evaluation of Fused/Ankylosed Hip with Severe Flexion Deformity after Conversion to Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Saroj Kumar Suwal

    2016-06-01

    Conclusions: THA is an effective treatment for ankylosed hip with severe flexion deformity although complications are noted more than routine hip arthroplasties. Keywords: ankylosed hip; fused hip; severe flexion deformity; total hip arthroplasty. | PubMed

  10. Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs

    Directory of Open Access Journals (Sweden)

    Gholam Hossein Shahcheraghi

    2015-09-01

    Full Text Available Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations. Methods: 52 primary cementless total hip arthroplasty in 42 patients with the mean age of 48.8 years were retrospectively studied. Two groups of prosthesis had been implanted: Harris-Galante II (HGII in 15 and Versys-Trilogy (V-T in 37 hips, both from Zimmer company. The patients were assessed clinically, radiographically and with Harris hip score, SF36, WOMAC, and MACTAR questionnaires, with 65 months (26-136 mean follow-up. Results: All the V-T prostheses had survived well. Eight of HG II were revised by the last follow-up in 19-102 months. All had undergone acetabular revision and 2 combined with femoral revision. Broken tines of HGII cups were seen in 4 radiographs. The 65 months overall survival was 96.2% for femoral and 84.6% for acetabular components. 90% had good or excellent Harris hip scores. The functional scores were poorer in the HG II group. Pain relief and improved walking were the two main patients’ expectations fulfilled in 97.6% and 92.8%, respectively. Conclusions: The outcome of cementless total hip arthroplasty (THA is satisfactory and comparable with the literature based on the results of function and survival of this small comparative group. The use of HGII acetabular component should be abandoned.

  11. Increasing Resistance of Coagulase-Negative Staphylococci in Total Hip Arthroplasty Infections: 278 THA-Revisions due to Infection Reported to the Norwegian Arthroplasty Register from 1993 to 2007

    Directory of Open Access Journals (Sweden)

    Olav Lutro

    2014-01-01

    Full Text Available We investigated bacterial findings from intraoperative tissue samples taken during revision due to infection after total hip arthroplasty (THA. The aim was to investigate whether the susceptibility patterns changed during the period from 1993 through 2007. Reported revisions due to infection in the Norwegian Arthroplasty Register (NAR were identified, and 10 representative hospitals in Norway were visited. All relevant information on patients reported to the NAR for a revision due to infection, including bacteriological findings, was collected from the medical records. A total of 278 revision surgeries with bacterial growth in more than 2 samples were identified and included. Differences between three 5-year time periods were tested by the chi-square test for linear trend. The most frequent isolates were coagulase-negative staphylococci (CoNS (41%, 113/278 and Staphylococcus aureus (19%, 53/278. The proportion of CoNS resistant to the methicillin-group increased from 57% (16/28 in the first period, 1993–1997, to 84% (52/62 in the last period, 2003–2007 (P = 0.003. There was also significant increase in resistance for CoNS to cotrimoxazole, quinolones, clindamycin, and macrolides. All S. aureus isolates were sensitive to both the methicillin-group and the aminoglycosides. For the other bacteria identified no changes in susceptibility patterns were found.

  12. A randomised controlled trial of total hip arthroplasty versus resurfacing arthroplasty in the treatment of young patients with arthritis of the hip joint.

    Science.gov (United States)

    Achten, Juul; Parsons, Nick R; Edlin, Richard P; Griffin, Damian R; Costa, Matthew L

    2010-01-14

    Hip replacement (arthroplasty) surgery is a highly successful treatment for patients with severe symptomatic arthritis of the hip joint. For older patients, several designs of Total Hip Arthroplasty have shown excellent results in terms of both function and value for money. However, in younger more active patients, there is approximately a 50% failure rate at 25 years for traditional implants. Hip resurfacing is a relatively new arthroplasty technique. In a recent review of the literature on resurfacing arthroplasty it was concluded that the short-term functional results appear promising but some potential early disadvantages were identified, including the risk of femoral neck fracture and collapse of the head of the femur. The aim of the current study is to assess whether there is a difference in functional hip scores at one year post-operation between Total Hip Arthroplasty and Resurfacing Arthroplasty. Secondary aims include assessment of complication rates for both procedures as well cost effectiveness. All patients medically fit for surgery and deemed suitable for a resurfacing arthroplasty are eligible to take part in this study. A randomisation sequence will be produced and administered independently. After consenting, all patients will be clinically reviewed and hip function, quality of life and physical activity level will be assessed through questionnaires. The allocated surgery will then be performed with the preferred technique of the surgeon. Six weeks post-operation hip function will be assessed and complications recorded. Three, six and 12 months post-operation hip function, quality of life and physical activity level will be assessed. Additional information about patients' out-of-pocket expenses will also be collected. Current Controlled Trials ISRCTN33354155. UKCLRN portfolio ID 4093.

  13. [Non-cemented self-locking total arthroplasty of the hip. Clinical and radiological results after three years].

    Science.gov (United States)

    Desjardins, A L; Roy, A; Duchesne, R; Béliveau, P; Fallaha, M; Bornais, S

    1993-01-01

    We reviewed 47 patients who had fifty-one (51) primary, cementless biofit total hip arthroplasties (THA) implanted at Maisonneuve-Rosemont Hospital between 1986 and 1990. An independent observer rated the patients on the Harris Hip Score (HHS) by questionnaire, physical examination and radiological assessment. The average follow-up was 40 months. Twenty-two percent (22%) of the femoral components had been revised because of incapacitating pain, limping or a HHS inferior to 60. A little more than 20% of the unrevised prostheses had a mediocre result (HHS inferior to 70). There was no correlation between results and radiological signs of instability. The femoral component of the hip arthroplasty has a poor clinical performance which compares unfavourably with cemented prostheses.

  14. The impact of subsidence on straight and curved modular cementless revision stems in hip revision surgery.

    Science.gov (United States)

    Fraile Suari, A; Gil González, S; Pérez Prieto, D; León García, A; Mestre Cortadellas, C; Tey Pons, M; Marqués López, F

    Subsidence is one of the potential complications in femoral stem revision total hip arthroplasty surgery, and can affect stability and osseointegration. A retrospective study was conducted on the outcomes at one year and 5 years (specifically subsidence and clinical relevance) of 40 consecutive femoral total hip arthroplasty revisions, comparing two modular cementless revision stems, Straight vs. Curved, with 20 patients in each group. No mechanical failure was observed, and there was an improvement in functional outcomes. Mean radiological subsidence was 9.9±4.9mm (straight=10.75mm vs. curved=9.03mm), with no statistically significant difference between groups (p=0,076). Fourteen patients (35%) had ≥10mm of subsidence, up to a maximum of 22mm. The subsidence found in this study is similar to published series, with no short-term clinical manifestations, or an increased number of complications or stem loosening in either the Straight or Curved group. No differences in subsidence were observed at one year and 5 years after surgery between the 2 types of stems. Copyright © 2017 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. Reverse hybrid total hip arthroplasty

    DEFF Research Database (Denmark)

    Wangen, Helge; Havelin, Leif I.; Fenstad, Anne M

    2017-01-01

    Background and purpose - The use of a cemented cup together with an uncemented stem in total hip arthroplasty (THA) has become popular in Norway and Sweden during the last decade. The results of this prosthetic concept, reverse hybrid THA, have been sparsely described. The Nordic Arthroplasty....... Patients and methods - From the NARA, we extracted data on reverse hybrid THAs from January 1, 2000 until December 31, 2013. 38,415 such hips were studied and compared with cemented THAs. The Kaplan-Meier method and Cox regression analyses were used to estimate the prosthesis survival and the relative risk...

  16. Activity and Quality of Life after Total Hip Arthroplasty.

    Science.gov (United States)

    Świtoń, Anna; Wodka-Natkaniec, Ewa; Niedźwiedzki, Łukasz; Gaździk, Tadeusz; Niedźwiedzki, Tadeusz

    2017-10-31

    Coxarthrosis is a chronic musculoskeletal condition that causes severe pain and considerable limi-tation of the patient's motor performance. Total hip arthroplasty is one of the most common and effective methods used in the treatment of advanced degenerative changes. The aim of the present study was to evaluate the activity and quality of life of patients after unilateral total hip arthroplasty. The study was conducted in a group of 189 patients who had undergone unilateral total hip arthroplasty. Goniometry was used to determine the range of motion of both hip joints. Patients' physical ability and pain severity were assessed based on the Harris Hip Score (HHS) questionnaire. The examination of the range of motion in the lower extremities revealed statistically significant diffe-rences in flexion (p<0.01), abduction (p=<0.01), adduction (p<0.01) and external rotation (p<0.01) between the operated and the healthy extremity. The greatest limitation of motion was demonstrated for external rotation (<14°). Approximately 14% of the patients were not able to perform this motion in their healthy hip joint, while 17.5% of them could not do so in the affected hip joint. Analysis of HHS results (mean = 79 pts) revealed that more than 50% of the patients described their functional ability and quality of life as good and excellent. It was demonstrated that 54% of patients did not suffer from pain, whereas minor or mild pain was noted in 35%. 1. A subjective clinical assessment of patients after total hip arthroplasty showed that their quality of life had improved. 2. It is necessary to perform physiotherapy after total hip arthroplasty, on both the operated and healthy side. 3. Exacerbation of pain and impaired activity in patients after total hip arthroplasty were associated with the female sex to a considerable extent.

  17. A quantitative assessment of facial protection systems in elective hip arthroplasty.

    Science.gov (United States)

    Hirpara, Kieran Michael; O'Halloran, Emily; O'Sullivan, Michael

    2011-06-01

    We aimed to assess the risk to surgeons of blood splatter during total hip arthroplasty. Hoods from personal protection systems used in 34 consecutive total hip replacements were collected and the area of blood splatter was measured and compared to goggles and visors. Thirty one primary THA's (13 cemented, 4 hybrid, 14 uncemented) and 3 revisions (1 hybrid, 2 uncemented) were collected. Splashes were detected on all of the masks with a mean of 034% cover. Splatter was greatest for the operating surgeon, followed by the first assistant, though the difference was not statistically significant. Operating personnel were at greater risk of contamination during uncemented arthroplasty (p blood cover was outside the area protected by goggles and visors respectively. There was a significant difference between the Personal Protection Systems (PPS) and goggles (p = 0.0231; 95% CI) as well as between the PPS and visors (p = 0.0293; 95% CI).

  18. TOTAL HIP ARTHROPLASTY IN CHILDREN WHO HAVE UNDERGONE ARTHROPLASTY WITH DEMINERALIZED BONE-CARTILAGE ALLOCUPS

    Directory of Open Access Journals (Sweden)

    Vladimir E. Baskov

    2017-03-01

    Full Text Available Introduction. Treating children with degenerative dystrophic diseases of the hip joint has become one of the most acute problems in contemporary orthopedics. Until recently, we performed arthroplasty by demineralized bone-cartilage allocups (DBCA in the Clinic of the Hip Joint Pathology of the Turner Scientific and Research Institute for Children’s Orthopedics for patients showing clinical and radiological signs of irreversible destruction of the hip joint; we carried out this procedure to preserve the function of the lower limb. However, over the last 8 years, we have changed our protocol for children older than 12 years of age and have replaced DBCA with total hip replacement. In a number of cases, total hip replacement was performed after a previous intervention involving arthroplasty with DBCA. Objective. To determine the technical peculiarities of total hip replacement after a previous intervention involving arthroplasty with DBCA. Material and methods. We analyzed the results of treatment involving various types of hip pathology in 13 children (100% aged between 15 and 16 years [8 girls (61.5% and 5 boys (38.5%]. The medical histories of all 13 children (100% showed repeated operations on the hip joint, ultimately resulting in arthroplasty with DBCA. All 13 children (100% underwent a total hip replacement. Upon hip replacement, all 13 patients (100% showed a pronounced thinning and hardening of the edges and the bottom of the acetabulum, which created some difficulties in the process of acetabular component implantation. The transformation of DBCA was not evident in any of the 13 cases (100%. Results. During the observation period of 3–5 years following total hip arthroplasty, all 13 cases (100% showed recovery in the range of motion and absence of pain. An important criterion for evaluating the quality of care was the complete social and domestic adaptation of all 13 children (100% during the period from 6 to 9 months following total

  19. Total hip arthroplasty in children who have undergone arthroplasty with demineralized bone-cartilage allocups

    Directory of Open Access Journals (Sweden)

    Vladimir E. Baskov

    2017-03-01

    Full Text Available Introduction. Treating children with degenerative dystrophic diseases of the hip joint has become one of the most acute problems in contemporary orthopedics. Until recently, we performed arthroplasty by demineralized bone-cartilage allocups (DBCA in the Clinic of the Hip Joint Pathology of the Turner Scientific and Research Institute for Children’s Orthopedics for patients showing clinical and radiological signs of irreversible destruction of the hip joint; we carried out this procedure to preserve the function of the lower limb. However, over the last 8 years, we have changed our protocol for children older than 12 years of age and have replaced DBCA with total hip replacement. In a number of cases, total hip replacement was performed after a previous intervention involving arthroplasty with DBCA. Objective. To determine the technical peculiarities of total hip replacement after a previous intervention involving arthroplasty with DBCA. Material and methods. We analyzed the results of treatment involving various types of hip pathology in 13 children (100% aged between 15 and 16 years [8 girls (61.5% and 5 boys (38.5%]. The medical histories of all 13 children (100% showed repeated operations on the hip joint, ultimately resulting in arthroplasty with DBCA. All 13 children (100% underwent a total hip replacement. Upon hip replacement, all 13 patients (100% showed a pronounced thinning and hardening of the edges and the bottom of the acetabulum, which created some difficulties in the process of acetabular component implantation. The transformation of DBCA was not evident in any of the 13 cases (100%. Results. During the observation period of 3–5 years following total hip arthroplasty, all 13 cases (100% showed recovery in the range of motion and absence of pain. An important criterion for evaluating the quality of care was the complete social and domestic adaptation of all 13 children (100% during the period from 6 to 9 months following total

  20. Sports Activity Following Cementless Metaphyseal Hip Joint Arthroplasty

    Directory of Open Access Journals (Sweden)

    Czech Szymon

    2017-12-01

    Full Text Available An adequate level of physical activity has a substantial effect on both mental and physical human health. Physical activity is largely dependent on the function of the musculoskeletal and articular system. One of the most frequent diseases of this system is degenerative joint disease. Due to the changing and more demanding lifestyles and patients’ willingness to be involved in sports activity, the expectations of hip joint arthroplasty are becoming increasingly high. Alleviating pain ceases to be the only reason for which patients choose surgical interventions, while the expectations often include involvement in various sports. Only few studies contain recommendations concerning the frequency, type and intensity of sports activity which are acceptable after hip joint arthroplasty. The aim of the study was to evaluate function and physical activity of people following cementless short-stem hip joint arthroplasty in the observation of at least five years. The study group comprised 106 patients who underwent total hip arthroplasty due to degenerative joint diseases, chosen according to inclusion criteria. Patients underwent routine physical examinations following the Harris Hip Score protocol, responded to the UCLA scale and questionnaires concerning pre-surgical and current physical activity. Our results demonstrated that hip joint arthroplasty in people suffering from degenerative joint diseases has a beneficial effect on their level of functioning and physical activity. Although physical activity and the level of functioning obviously reduced as a person aged, the level of physical activity continued to be very high in both groups, with function of the hip joint evaluated as very good.

  1. Sports Activity Following Cementless Metaphyseal Hip Joint Arthroplasty.

    Science.gov (United States)

    Czech, Szymon; Hermanson, Jacek; Rodak, Piotr; Stołtny, Tomasz; Rodak, Łukasz; Kasperczyk, Sławomir; Koczy, Bogdan; Mielnik, Michał

    2017-12-01

    An adequate level of physical activity has a substantial effect on both mental and physical human health. Physical activity is largely dependent on the function of the musculoskeletal and articular system. One of the most frequent diseases of this system is degenerative joint disease. Due to the changing and more demanding lifestyles and patients' willingness to be involved in sports activity, the expectations of hip joint arthroplasty are becoming increasingly high. Alleviating pain ceases to be the only reason for which patients choose surgical interventions, while the expectations often include involvement in various sports. Only few studies contain recommendations concerning the frequency, type and intensity of sports activity which are acceptable after hip joint arthroplasty. The aim of the study was to evaluate function and physical activity of people following cementless short-stem hip joint arthroplasty in the observation of at least five years. The study group comprised 106 patients who underwent total hip arthroplasty due to degenerative joint diseases, chosen according to inclusion criteria. Patients underwent routine physical examinations following the Harris Hip Score protocol, responded to the UCLA scale and questionnaires concerning pre-surgical and current physical activity. Our results demonstrated that hip joint arthroplasty in people suffering from degenerative joint diseases has a beneficial effect on their level of functioning and physical activity. Although physical activity and the level of functioning obviously reduced as a person aged, the level of physical activity continued to be very high in both groups, with function of the hip joint evaluated as very good.

  2. Total hip arthroplasty revision due to infection: a cost analysis approach.

    Science.gov (United States)

    Klouche, S; Sariali, E; Mamoudy, P

    2010-04-01

    The treatment of total hip arthroplasty (THA) infections is long and costly. However,the number of studies in the literature analysing the real cost of THA revision in relation to their etiology, including infection, is limited. The aim of this retrospective study was to determine the cost of revision of infected THA and to compare these costs to those of primary THA and revision of non-infected THA. We performed a retrospective cost analysis for the year 2006 using an identical analytic accounting system in each hospital department (according to internal criteria) based on allotment of direct costs and receipts for each department. From January to December 2006, 424 primary THA, 57 non-infected THA revisions and 40 THA revisions due to infection were performed. The different cost areas of the patient's treatment were identified.This included preoperative medical work-up, medicosurgical management during hospital stay,a second stay in an orthopedic rehabilitation hospital (ORH) and post-hospitalisation antibiotic therapy after revision due to infection, as well as home-based hospitalisation (HH) costs, if this was the selected alternative option. We used the national health insurance fee schedule found in the "Common classification of medical procedures" and the "General nomenclature of professional procedures" applicable in France since September 1, 2005. Hospital costs included direct costs (hospital overhead costs) and indirect costs, (medical, surgical, technical settings and net general service expenses). The calculation of HH costs and ORH costs were based on the average daily charge of these departments. The cost of primary THA was used as the reference.We then compared our surgical costs with those found for the corresponding comparable hospital stay groups (Groupes homogènes de séjour). The average hospital stay (AHS) was 7.5 +/- 1.8 days for primary THA, 8.9 +/- 2.2 days for non-infected revisions and 30.6 +/- 14.9 days for revisions due to infection

  3. Arthrography of painful hips following arthroplasty: Digital versus plain film subtraction

    Energy Technology Data Exchange (ETDEWEB)

    Walker, C W; FitzRandolph, R L; Dalrymple, G V [Arkansas Univ. for Medical Sciences, Little Rock, AR (USA). Dept. of Radiology John McClellan Memorial Veterans Hospital, Little Rock, AR (USA); Collins, D N [Arkansas Univ. for Medical Sciences, Little Rock, AR (USA). Dept. of Orthopedics John McClellan Memorial Veterans Hospital, Little Rock, AR (USA)

    1991-08-01

    Digital and manual subtraction images obtained during the arthrographic evaluation of 78 painful hip prostheses were reviewed retrospectively. Revision arthroplasty was performed in 53 of these cases, and the arthrographic and surgical findings were correlated. The digital and manual subtraction images were evaluated without knowledge of the surgical results using established criteria for component loosening. The difference between detection of femoral component loosening on digital as opposed to manual subtraction images was statistically significant (P < 0.05). This study demonstrates that digital subtraction improves the evaluation of femoral component loosening in painful hip prostheses. (orig./GDG).

  4. Early failure mechanisms of constrained tripolar acetabular sockets used in revision total hip arthroplasty.

    Science.gov (United States)

    Cooke, Christopher C; Hozack, William; Lavernia, Carlos; Sharkey, Peter; Shastri, Shani; Rothman, Richard H

    2003-10-01

    Fifty-eight patients received an Osteonics constrained acetabular implant for recurrent instability (46), girdlestone reimplant (8), correction of leg lengthening (3), and periprosthetic fracture (1). The constrained liner was inserted into a cementless shell (49), cemented into a pre-existing cementless shell (6), cemented into a cage (2), and cemented directly into the acetabular bone (1). Eight patients (13.8%) required reoperation for failure of the constrained implant. Type I failure (bone-prosthesis interface) occurred in 3 cases. Two cementless shells became loose, and in 1 patient, the constrained liner was cemented into an acetabular cage, which then failed by pivoting laterally about the superior fixation screws. Type II failure (liner locking mechanism) occurred in 2 cases. Type III failure (femoral head locking mechanism) occurred in 3 patients. Seven of the 8 failures occurred in patients with recurrent instability. Constrained liners are an effective method for treatment during revision total hip arthroplasty but should be used in select cases only.

  5. Total Hip Arthroplasty in Patients With Avascular Necrosis After Hematopoietic Stem Cell Transplantation.

    Science.gov (United States)

    Vijapura, Anita; Levine, Harlan B; Donato, Michele; Hartzband, Mark A; Baker, Melissa; Klein, Gregg R

    2018-03-01

    The immunosuppressive regimens required for hematopoietic stem cell transplantation predispose recipients to complications, including avascular necrosis. Cancer-related comorbidities, immunosuppression, and poor bone quality theoretically increase the risk for perioperative medical complications, infection, and implant-related complications in total joint arthroplasty. This study reviewed 20 primary total hip arthroplasties for avascular necrosis in 14 patients. Outcomes were assessed at routine clinical visits and Harris hip scores were calculated. Follow-up radiographs were evaluated for component malposition, loosening, polyethylene wear, and osteolysis. Average follow-up was 44.5 months for all patients. Postoperative clinical follow-up revealed good to excellent outcomes, with significant improvement in functional outcome scores. There were no periprosthetic infections or revisions for aseptic loosening. There was 1 dislocation on postoperative day 40, which was treated successfully with a closed reduction. Two patients with a prior history of venous thromboembolism developed a pulmonary embolus on postoperative day 13 and 77, respectively. Four patients died several months to years after arthroplasty of complications unrelated to the surgical procedure. Total hip arthroplasty can both be safely performed and greatly improve quality of life in recipients of hematopoietic stem cell transplantation who develop avascular necrosis. However, prolonged venous thromboembolism prophylaxis should be carefully considered in this high-risk patient population. [Orthopedics. 2018; 41(2):e257-e261.]. Copyright 2018, SLACK Incorporated.

  6. Perioperative blood saving measures in total hip and knee arthroplasty

    NARCIS (Netherlands)

    Horstmann, W.G.

    2011-01-01

    This dissertation explores and discusses different aspects of blood loss and blood-saving measures in total hip and knee arthroplasty. Background: Worldwide, approximately 1 million total hip and 1 million total knee prostheses are implanted each year. Total hip arthroplasty and total

  7. Indirect lateral surgical approach modified in hip arthroplasty

    International Nuclear Information System (INIS)

    Sanchez, Pedro Antonio; Arbelaez, William Rafael

    2006-01-01

    The authors show an another option to the surgical approach to the hip, a lateral indirect modified (ALIM) for the partial or total arthroplasty of primary hip replacement and for revision (RTC), in a retrospective study, series of cases, with average was 7,75 years of follow up (range 6 months-10 years); quick access, easy technically, provide a good orientation of the components of the placement of implants, and allow an excellent exhibition for the complex problems of the reconstruction of the acetabular and the femur. Leaves intact the greater trochanter, improving the rotational stability that is needed in its femoral implant, doesn't injured the gluteus medius and doesn't produces his deficit, reduce the time for the deambulation. This approach is designed for primary cases and complex cases of revision using the mini-incision, with better exposition and less morbid-mortality associated to the surgical technique due to the less bleeding, less incidence of dislocation, thromboembolism and infection because of the little damage and better control of the surrounding soft tissue; better stability, no paralysis or lesion of the sciatic or femoral nerve without incidence of heterotopic ossifications with a better range of external rotation in extension of the hip that with traditional approach of Hardinge, and greater versatility in its indications

  8. Large head metal-on-metal cementless total hip arthroplasty versus 28mm metal-on-polyethylene cementless total hip arthroplasty: design of a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    van Raaij Jos JAM

    2008-10-01

    Full Text Available Abstract Background Osteoarthritis of the hip is successfully treated by total hip arthroplasty with metal-on-polyethylene articulation. Polyethylene wear debris can however lead to osteolysis, aseptic loosening and failure of the implant. Large head metal-on-metal total hip arthroplasty may overcome polyethylene wear induced prosthetic failure, but can increase systemic cobalt and chromium ion concentrations. The objective of this study is to compare two cementless total hip arthroplasties: a conventional 28 mm metal-on-polyethylene articulation and a large head metal-on-metal articulation. We hypothesize that the latter arthroplasties show less bone density loss and higher serum metal ion concentrations. We expect equal functional scores, greater range of motion, fewer dislocations, fewer periprosthetic radiolucencies and increased prosthetic survival with the metal-on-metal articulation. Methods A randomized controlled trial will be conducted. Patients to be included suffer from non-inflammatory degenerative joint disease of the hip, are aged between 18 and 80 and are admitted for primary cementless unilateral total hip arthroplasty. Patients in the metal-on-metal group will receive a cementless titanium alloy acetabular component with a cobalt-chromium liner and a cobalt-chromium femoral head varying from 38 to 60 mm. Patients in the metal-on-polyethylene group will receive a cementless titanium alloy acetabular component with a polyethylene liner and a 28 mm cobalt-chromium femoral head. We will assess acetabular bone mineral density by dual energy x-ray absorptiometry (DEXA, serum ion concentrations of cobalt, chromium and titanium, self reported functional status (Oxford hip score, physician reported functional status and range of motion (Harris hip score, number of dislocations and prosthetic survival. Measurements will take place preoperatively, perioperatively, and postoperatively (6 weeks, 1 year, 5 years and 10 years. Discussion

  9. Endoscopic resection of acetabular screw tip to decompress sciatic nerve following total hip arthroplasty.

    Science.gov (United States)

    Yoon, Sun-Jung; Park, Myung-Sik; Matsuda, Dean K; Choi, Yun Ho

    2018-06-04

    Sciatic nerve injuries following total hip arthroplasty are disabling complications. Although degrees of injury are variable from neuropraxia to neurotmesis, mechanical irritation of sciatic nerve might be occurred by protruding hardware. This case shows endoscopic decompression for protruded acetabular screw irritating sciatic nerve, the techniques described herein may permit broader arthroscopic/endoscopic applications for management of complications after reconstructive hip surgery. An 80-year-old man complained of severe pain and paresthesias following acetabular component revision surgery. Physical findings included right buttock pain with radiating pain to lower extremity. Radiographs and computed tomography imaging showed that the sharp end of protruded screw invaded greater sciatic foramen anterior to posterior and distal to proximal direction at sciatic notch level. A protruding tip of the acetabular screw at the sciatic notch was decompressed by use of techniques gained from experience performing endoscopic sciatic nerve decompression. The pre-operative pain and paresthesias resolved post-operatively after recovering from anesthesia. This case report describes the first documented endoscopic resection of the tip of the acetabular screw irritating sciatic nerve after total hip arthroplasty. If endoscopic resection of an offending acetabular screw can be performed in a safe and minimally invasive manner, one can envision a future expansion of the role of hip arthroscopic surgery in several complications management after total hip arthroplasty.

  10. A Review of Periprosthetic Femoral Fractures Associated With Total Hip Arthroplasty

    Science.gov (United States)

    Marsland, Daniel; Mears, Simon C.

    2012-01-01

    Periprosthetic fractures of the femur in association with total hip arthroplasty are increasingly common and often difficult to treat. Patients with periprosthetic fractures are typically elderly and frail and have osteoporosis. No clear consensus exists regarding the optimal management strategy because there is limited high-quality research. The Vancouver classification facilitates treatment decisions. In the presence of a stable prosthesis (type-B1 and -C fractures), most authors recommend surgical stabilization of the fracture with plates, strut grafts, or a combination thereof. In up to 20% of apparent Vancouver type-B1 fractures, the femoral stem is loose, which may explain the high failure rates associated with open reduction and internal fixation. Some authors recommend routine opening and dislocation of the hip to perform an intraoperative stem stability test to rule out a loose component. Advances in plating techniques and technology are improving the outcomes for these fractures. For fractures around a loose femoral prosthesis (types B2 and 3), revision using an extensively porous-coated uncemented long stem, with or without additional fracture fixation, appears to offer the most reliable outcome. Cement-in-cement revision using a long-stem prosthesis is feasible in elderly patients with a well-fixed cement mantle. It is essential to treat the osteoporosis to help fracture healing and to prevent further fractures. We provide an overview of the causes, classification, and management of periprosthetic femoral fractures around a total hip arthroplasty based on the current best available evidence. PMID:23569704

  11. A quantitative assessment of facial protection systems in elective hip arthroplasty.

    LENUS (Irish Health Repository)

    Hirpara, Kieran Michael

    2011-06-01

    We aimed to assess the risk to surgeons of blood splatter during total hip arthroplasty. Hoods from personal protection systems used in 34 consecutive total hip replacements were collected and the area of blood splatter was measured and compared to goggles and visors. Thirty one primary THA\\'s (13 cemented, 4 hybrid, 14 uncemented) and 3 revisions (1 hybrid, 2 uncemented) were collected. Splashes were detected on all of the masks with a mean of 034% cover. Splatter was greatest for the operating surgeon, followed by the first assistant, though the difference was not statistically significant. Operating personnel were at greater risk of contamination during uncemented arthroplasty (p < 0.0001; 95% CI). On average 50.60% and 45.40% of blood cover was outside the area protected by goggles and visors respectively. There was a significant difference between the Personal Protection Systems (PPS) and goggles (p = 0.0231; 95% CI) as well as between the PPS and visors (p = 0.0293; 95% CI).

  12. Automatic assessment of volume asymmetries applied to hip abductor muscles in patients with hip arthroplasty

    Science.gov (United States)

    Klemt, Christian; Modat, Marc; Pichat, Jonas; Cardoso, M. J.; Henckel, Joahnn; Hart, Alister; Ourselin, Sebastien

    2015-03-01

    Metal-on-metal (MoM) hip arthroplasties have been utilised over the last 15 years to restore hip function for 1.5 million patients worldwide. Althoug widely used, this hip arthroplasty releases metal wear debris which lead to muscle atrophy. The degree of muscle wastage differs across patients ranging from mild to severe. The longterm outcomes for patients with MoM hip arthroplasty are reduced for increasing degrees of muscle atrophy, highlighting the need to automatically segment pathological muscles. The automated segmentation of pathological soft tissues is challenging as these lack distinct boundaries and morphologically differ across subjects. As a result, there is no method reported in the literature which has been successfully applied to automatically segment pathological muscles. We propose the first automated framework to delineate severely atrophied muscles by applying a novel automated segmentation propagation framework to patients with MoM hip arthroplasty. The proposed algorithm was used to automatically quantify muscle wastage in these patients.

  13. Two-stage revision of infected hip arthroplasty using a shortened post-operative course of antibiotics.

    LENUS (Irish Health Repository)

    McKenna, Paul B

    2009-04-01

    We present a series of 30 consecutive patients with 31 infected total hip arthroplasties treated by a single surgeon over a 4-year period in whom a shortened post-operative course of antimicrobial chemotherapy was used.

  14. Long Term Outcomes of Total Hip Arthroplasty in Young Patients under 30

    Directory of Open Access Journals (Sweden)

    Emilios Pakos

    2014-09-01

    Full Text Available Background:  We aimed to report outcomes of total hip arthroplasty (THA in very young patients under the year of 30.   Methods:  Thirty patients (45 hips with various indications for THA were retrospectively reviewed radiologically and clinically and analyzed regarding survival, reasons of failure, factors associated with outcomes and postoperative complications.   Results:  Within a mean follow-up time of 116 months the 10-year survival rate was 90.3%. All hips were revised due to aseptic loosening. No association was found among the tested parameters with increased revision rates.Three complications associated with the THA were recorded and managed conservatively. All patients had statistically significant improved clinical scores compared to the pre-operative period, despite the underlying disorder that compromised the condition in the majority of the patients. Conclusions:  Our study showed excellent long term outcomes of THA in patients younger than 30 years of age, comparable with those in older patients.

  15. Two-stage revision surgery with preformed spacers and cementless implants for septic hip arthritis: a prospective, non-randomized cohort study

    Directory of Open Access Journals (Sweden)

    Logoluso Nicola

    2011-05-01

    Full Text Available Abstract Background Outcome data on two-stage revision surgery for deep infection after septic hip arthritis are limited and inconsistent. This study presents the medium-term results of a new, standardized two-stage arthroplasty with preformed hip spacers and cementless implants in a consecutive series of adult patients with septic arthritis of the hip treated according to a same protocol. Methods Nineteen patients (20 hips were enrolled in this prospective, non-randomized cohort study between 2000 and 2008. The first stage comprised femoral head resection, debridement, and insertion of a preformed, commercially available, antibiotic-loaded cement hip spacer. After eradication of infection, a cementless total hip arthroplasty was implanted in the second stage. Patients were assessed for infection recurrence, pain (visual analog scale [VAS] and hip joint function (Harris Hip score. Results The mean time between first diagnosis of infection and revision surgery was 5.8 ± 9.0 months; the average duration of follow up was 56.6 (range, 24 - 104 months; all 20 hips were successfully converted to prosthesis an average 22 ± 5.1 weeks after spacer implantation. Reinfection after total hip joint replacement occurred in 1 patient. The mean VAS pain score improved from 48 (range, 35 - 84 pre-operatively to 18 (range, 0 - 38 prior to spacer removal and to 8 (range, 0 - 15 at the last follow-up assessment after prosthesis implantation. The average Harris Hip score improved from 27.5 before surgery to 61.8 between the two stages to 92.3 at the final follow-up assessment. Conclusions Satisfactory outcomes can be obtained with two-stage revision hip arthroplasty using preformed spacers and cementless implants for prosthetic hip joint infections of various etiologies.

  16. Cost of Radiotherapy Versus NSAID Administration for Prevention of Heterotopic Ossification After Total Hip Arthroplasty

    International Nuclear Information System (INIS)

    Strauss, Jonathan B.; Chen, Sea S.; Shah, Anand P.; Coon, Alan B.; Dickler, Adam

    2008-01-01

    Purpose: Heterotopic ossification (HO), or abnormal bone formation, is a common sequela of total hip arthroplasty. This abnormal bone can impair joint function and must be surgically removed to restore mobility. HO can be prevented by postoperative nonsteroidal anti-inflammatory drug (NSAID) use or radiotherapy (RT). NSAIDs are associated with multiple toxicities, including gastrointestinal bleeding. Although RT has been shown to be more efficacious than NSAIDs at preventing HO, its cost-effectiveness has been questioned. Methods and Materials: We performed an analysis of the cost of postoperative RT to the hip compared with NSAID administration, taking into account the costs of surgery for HO formation, treatment-induced morbidity, and productivity loss from missed work. The costs of RT, surgical revision, and treatment of gastrointestinal bleeding were estimated using the 2007 Medicare Fee Schedule and inpatient diagnosis-related group codes. The cost of lost wages was estimated using the 2006 median salary data from the U.S. Census Bureau. Results: The cost of administering RT was estimated at $899 vs. $20 for NSAID use. After accounting for the additional costs associated with revision total hip arthroplasty and gastrointestinal bleeding, the corresponding estimated costs were $1,208 vs. $930. Conclusion: If the costs associated with treatment failure and treatment-induced morbidity are considered, the cost of NSAIDs approaches that of RT. Other NSAID morbidities and quality-of-life differences that are difficult to quantify add to the cost of NSAIDs. These considerations have led us to recommend RT as the preferred modality for use in prophylaxis against HO after total hip arthroplasty, even when the cost is considered

  17. Migration characteristics and early clinical results of the NANOS® short-stem hip arthroplasty.

    Science.gov (United States)

    Kaipel, Martin; Grabowiecki, Phillip; Sinz, Katrina; Farr, Sebastian; Sinz, Günter

    2015-05-01

    Femoral short stems promise essential advantages in total hip arthroplasty. Up to now, only short- and midterm clinical studies exist. Data on early stem migration that could predict later aseptic loosening at an early stage are rare. The purpose of this study was to assess migration patterns and clinical outcome 2 years after hip replacement by a metaphyseal anchored cementless short stem. Migration data and clinical results were prospectively assessed in 49 patients. Clinical outcome was measured using the Harris Hip Score (HHS). Migration analyses were performed using the computer-assisted Einzel-Bild-Roentgen-Analyse (EBRA) system. At 2 years after surgery, none of the implants needed revision, and HHS increased from 47.9 up to 98.1. Of 49 patients, 5 (10%) showed increased vertical stem migration (1.5 mm/2a) that might predict late aseptic loosening. Of 49 stems, 44 (90%) showed stable migration patterns indicating a beneficial long-term outcome. Results of this study confirm the excellent clinical data of previous works. Migration patterns strongly suggest that short-stem arthroplasty is not only an innovative but also a reliable strategy in total hip replacement.

  18. Management of metal-on-metal hip implant patients: Who, when and how to revise?

    Science.gov (United States)

    Berber, Reshid; Skinner, John A; Hart, Alister J

    2016-05-18

    The debate on how best to manage patients with metal-on-metal (MOM) hip implants continues. With over 1 million patients affected worldwide, the impact is far reaching. The majority of the aggressive failures of MOM hip implants have been dealt with by revision hip surgery, leaving patients with a much more indolent pattern of failure of devices that have been in situ for more than 10 years. The longer-term outcome for such patients remains unknown, and much debate exists on how best to manage these patients. Regulatory guidance is available but remains open to interpretation due to the lack of current evidence and long-term studies. Metal ion thresholds for concern have been suggested at 7 ppb for hip resurfacing arthroplasty and below this level for large diameter total hip arthroplasties. Soft tissue changes including pseudotumours and muscle atrophy have been shown to progress, but this is not consistent. New advanced imaging techniques are helping to diagnose complications with metal hips and the reasons for failure, however these are not widely available. This has led to some centres to tackle difficult cases through multidisciplinary collaboration, for both surgical management decisions and also follow-up decisions. We summarise current evidence and consider who is at risk, when revision should be undertaken and how patients should be managed.

  19. Metal-on-Metal Total Hip Resurfacing Arthroplasty: An Evidence-Based Analysis.

    Science.gov (United States)

    2006-01-01

    The objective of this review was to assess the safety and effectiveness of metal on metal (MOM) hip resurfacing arthroplasty for young patients compared with that of total hip replacement (THR) in the same population. Total hip replacement has proved to be very effective for late middle-aged and elderly patients with severe degenerative diseases of the hips. As indications for THR began to include younger patients and those with a more active life style, the longevity of the implant became a concern. Evidence suggests that these patients experience relatively higher rates of early implant failure and the need for revision. The Swedish hip registry, for example, has demonstrated a survival rate in excess of 80% at 20 years for those aged over 65 years, whereas this figure was 33% by 16 years in those aged under 55 years. Hip resurfacing arthroplasty is a bone-conserving alternative to THR that restores normal joint biomechanics and load transfer. The technique has been used around the world for more than 10 years, specifically in the United Kingdom and other European countries. Metal-on-metal hip resurfacing arthroplasty is an alternative procedure to conventional THR in younger patients. Hip resurfacing arthroplasty is less invasive than THR and addresses the problem of preserving femoral bone stock at the initial operation. This means that future hip revisions are possible with THR if the initial MOM arthroplasty becomes less effective with time in these younger patients. The procedure involves the removal and replacement of the surface of the femoral head with a hollow metal hemisphere, which fits into a metal acetabular cup. Hip resurfacing arthroplasty is a technically more demanding procedure than is conventional THR. In hip resurfacing, the femoral head is retained, which makes it much more difficult to access the acetabular cup. However, hip resurfacing arthroplasty has several advantages over a conventional THR with a small (28 mm) ball. First, the large

  20. Arthroscopic bursectomy for recalcitrant trochanteric bursitis after hip arthroplasty.

    Science.gov (United States)

    Van Hofwegen, Christopher; Baker, Champ L; Savory, Carlton G; Baker, Champ L

    2013-01-01

    This study evaluated the use of arthroscopic bursectomy for pain relief in patients with trochanteric bursitis after hip arthroplasty. In this retrospective case series of 12 patients undergoing arthroscopic treatment of recalcitrant trochanteric bursitis after hip arthroplasty, outcomes were assessed via phone interview with a numeric pain rating scale from 1 to 10 and were compared with preoperative pain ratings. Patients were asked the percentage of time they had painless hip function and whether they would have the surgery again. At an average 36-month follow-up (range, 4-85 months), the average numeric pain scale rating improved from 9.3 to 3.3. At an average of 62% of the time, patients had painless use of the hip. Ten of 12 patients in the study felt the pain relief gained was substantial enough to warrant having procedure again. In these patients, arthroscopic bursectomy was a viable option for patients with recalcitrant bursitis after hip arthroplasty.

  1. Comparison of acetabular reamings during hip resurfacing versus uncemented total hip arthroplasty.

    LENUS (Irish Health Repository)

    Brennan, S A

    2009-04-01

    PURPOSE: To compare the quantity of bone removed from the acetabulum during resurfacing hip arthroplasty versus uncemented total hip arthroplasty (THA). METHODS: 62 consecutive patients with osteoarthritis of the hip were prospectively studied. 24 men and 7 women aged 40 to 86 (mean, 59) years underwent Birmingham hip resurfacing. 13 men and 18 women aged 34 to 88 (mean, 61) years underwent uncemented THA using the trident acetabular cup. Obese elderly women at risk of femoral neck fracture and patients with large subchondral pseudocysts or a history of avascular necrosis of the femoral head were assigned to uncemented THA. Acetabular reamings were collected; marginal osteophytes were not included. The reamings were dehydrated, defatted, and weighed. RESULTS: The mean weight of acetabular reamings was not significantly different between patients undergoing hip resurfacing and uncemented THA (p=0.57). CONCLUSION: In hip resurfacing, the use of an appropriately small femoral component avoids oversizing the acetabular component and removal of excessive bone stock.

  2. Postoperative effects of neuromuscular exercise prior to hip or knee arthroplasty

    DEFF Research Database (Denmark)

    Villadsen, Allan; Overgaard, Søren; Holsgaard-Larsen, Anders

    2014-01-01

    neuromuscular exercise prior to total joint arthroplasty (TJA) of the hip or knee did not confer additional benefits 3 months postoperatively compared with TJA alone. However, the intervention group experienced a statistically significant short-term benefit in ADL and pain, suggesting an earlier onset......OBJECTIVE: To investigate the postoperative efficacy of a supervised programme of neuromuscular exercise prior to hip or knee arthroplasty. METHODS: In this assessor-blinded randomised controlled trial, we included 165 patients scheduled for hip or knee arthroplasty due to severe osteoarthritis (OA......). An 8-week preoperative neuromuscular supervised exercise programme was delivered twice a week for 1 h as adjunct treatment to the standard arthroplasty procedure and compared with the standard arthroplasty procedure alone. The primary outcome was self-reported physical function measured...

  3. Bilateral simultaneous total hip arthroplasty in a fast track setting

    DEFF Research Database (Denmark)

    Otte, Kristian S; Husted, Henrik; Ørsnes, Thue

    2011-01-01

    and low complication rates when performed in a fast-track setting. We believed it would be useful to assess hip arthroplasty in this context, and we report 50 consecutive fast-track simultaneous bilateral hip arthroplasty procedures. The median length of stay was 4 days. Mortality within 90 days was 4......% and 8% required a further operative procedure. The overall complication rate was 22%. 55% of the complications were considered to be caused by failures in surgical technique and 45% by other factors. Bilateral simultaneous hip arthroplasty may have a high complication rate in a fast-track setting...

  4. Hip dislocations after 2,734 elective unilateral fast-track total hip arthroplasties

    DEFF Research Database (Denmark)

    Jørgensen, Christoffer Calov; Kjærsgaard-Andersen, Per; Kehlet, Henrik

    2014-01-01

    STUDY DESIGN: Retrospective review of prospectively collected data. OBJECTIVE: To investigate the incidence of hip dislocation 90 days after total hip arthroplasty in relation to time after surgery, mechanism of dislocation and predisposing factors. METHODS: Prospective data on preoperative patient.......31-3.40)] but not hospital stay of hip...

  5. Hip fusion takedown to a total hip arthroplasty-is it worth it? A systematic review.

    Science.gov (United States)

    Jauregui, Julio J; Kim, Joseph K; Shield, William P; Harb, Matthew; Illical, Emmanuel M; Adib, Farshad; Maheshwari, Aditya V

    2017-08-01

    Patients with surgically or spontaneously fused hips are often dissatisfied with their overall function and the debilitating effect on adjacent joints. Therefore, in properly selected patients, hip fusion-takedown and conversion to total hip arthroplasty (THA) can result in improved function and decreased pain. We aimed to (1) evaluate the indications for conversion, (2) evaluate the clinical outcomes, (3) analyze the overall complications, and (4) identify the overall satisfaction following the procedure. A systematic and comprehensive literature search was performed to analyze studies evaluating conversion of hip fusion to THA. After reviewing 3,882 studies, 27 total studies (1,104 hips) met our inclusion/exclusion criteria and were included in our final analysis. A weighted mean of rates was determined for each complication, including infection, instability, loosening, nerve-related, abductor-related, venous thrombotic event, and revision. The study population consisted of 53.2% male and 46.8% female subjects. The mean age at time of conversion was 52 years (range 36-65 years), the mean time until follow-up was 9.2 years (range 2.5-17.3), and the mean duration of arthrodesis was 27.7 years (range 11-40.2). As measured by Harris Hip Score, overall clinical outcomes improved from 58.1 points (range 42.4-70 points) pre-operatively to 80.0 (range 62-93.5) post-operatively. The specific complication rates were 5.3% (range 0-43.6%) for infection, 2.6% (range 0-15.4%) for instability, 6.2% (range 0-17.2%) for loosening, 4.7% (range 0-13%) for nerve-related complications, 13.1% (range 0-87%) for abductor-related complications, and 1.2% (range 0-13%) for venous thrombotic events. The revision rate was 12.0% (range 0-43.6%). Takedown of a fused-hip can be a challenging procedure. Although patients can benefit functionally, both patients and surgeons need to be aware of the complications and increased risk of further revision procedures, which should be an important

  6. The Popularity of Outcome Measures for Hip and Knee Arthroplasties.

    Science.gov (United States)

    Lovelock, Thomas M; Broughton, Nigel S; Williams, Cylie M

    2018-01-01

    The optimal methods of determining outcomes following hip and knee arthroplasty remain controversial. The objectives of this study were to determine the most frequently used outcome measures in randomized controlled trials (RCT) and study protocols registered with clinical trials registries (CTR) on hip and knee arthroplasty. A systematic search strategy was undertaken to identify the outcome measures used in RCT and CTR following joint arthroplasty. Databases searched included Embase, Ovid MEDLINE (including In-Process), Cochrane Central Register of Controlled Trials, CINAHL Plus, clinicaltrials.gov, ISRCTN registry, and ANZCTR. Differences in the use of outcome measures between RCT and CTR were assessed using logistic regression. There were 291 RCT and 113 CTR on hip arthroplasty and 452 RCT and 184 CTR on knee arthroplasty that met the inclusion criteria. The most popular outcome measures were the Harris Hip Score and the Knee Society Score. Multiple outcome measures were used in greater than 50% of the included studies. The Oxford Hip Score, Oxford Knee Score, EuroQol-5D, and Knee Injury and Osteoarthritis Outcome Score (all P < .001) were used in significantly more CTR than RCT. There is a clear preference for the use of the Harris Hip Score and Knee Society Score, contrary to existing international guidelines and reviews on the topic. Both measures require clinician input, which potentially influences their validity and increases their overall administration cost. Some patient-reported outcome measures, such as the Oxford Hip and Knee Scores, EuroQol-5D, and KOOS, appear to be increasing in popularity. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Humeral windows in revision total elbow arthroplasty.

    Science.gov (United States)

    Peach, Chris A; Salama, Amir; Stanley, David

    2016-04-01

    The use of cortical windows for revision elbow arthroplasty has not previously been widely reported. Their use aids safe revision of a well fixed humeral prosthesis and can be used in the setting of dislocation, periprosthetic fracture or aseptic loosening of the ulnar component. We describe our technique and results of cortical windows in the distal humerus for revision elbow arthroplasty surgery.

  8. Hip resurfacing arthroplasty: current status and future perspectives

    Directory of Open Access Journals (Sweden)

    K Corten

    2011-03-01

    Full Text Available Hip resurfacing arthroplasty (HRA is a concept of hip replacement that allows treating young active patients with a femoral bone preserving procedure. The proposed advantages of resuming an active lifestyle with increased frequency and duration of sports activities have been shown to be realistic. The 30-year cost-effectiveness in young male patients has been shown to be higher in resurfacing compared to conventional total hip replacement (THA. However, prognosticators of an inferior outcome have also been identified. The most important patient related factors are secondary osteoarthritis as the indication for surgery such as post-childhood hip disorders or AVN, female gender, smaller component sizes and older age (>65 years for males and >55 years for females. In addition, surgical technique (approach and cementing technique and component design are also important determinant factors for the risk of failure. Moreover, concerns have surfaced with respect to high metal ion concentrations and metal ion hypersensitivities. In addition, the presumed ease of revising HRA has not reflected in improved or equal survivorship in comparison to a primary THA. This highlights the importance of identifying patient-, surgery-, and implant-related prognosticators for success or failure of HRA. Rather than vilifying the concept of hip resurfacing, detailed in depth analysis should be used to specify indications and improve implant design and surgical techniques.

  9. Hip resurfacing arthroplasty in treatment of avascular necrosis of the femoral head.

    Science.gov (United States)

    Pyda, Michał; Koczy, Bogdan; Widuchowski, Wojciech; Widuchowska, Małgorzata; Stołtny, Tomasz; Mielnik, Michał; Hermanson, Jacek

    2015-01-25

    Hip resurfacing is a conservative type of total hip arthroplasty but its use is controversial, especially in patients with osteonecrosis. The aim of this study was analysis of the clinical and radiographic outcomes of hip resurfacing in patients with osteonecrosis. Between 2007 and 2008, 30 hip resurfacing arthroplasties were performed due to osteoarthritis secondary to avascular necrosis of femoral head staged as Ficat III and IV. Patients were qualified to resurfacing arthroplasty when the extent of avascular necrosis using Kerboul's method was avascular necrosis and head-neck junction was >20°. All patients were evaluated clinically and radiologically before and 60 months after the operation. The mean Harris Hip Score (HHS) score increased from 47.8 to 94.25 (p<0.05). Physical activity level (University of California, Los Angeles activity score--UCLA activity score) improved from 3.7 to 7.55 (p<0.05). No implant migration was observed. Management of osteonecrosis of the hip with resurfacing arthroplasty seems to be effective in strictly-selected patients.

  10. Digital tomosynthesis with metal artifact reduction for assessing cementless hip arthroplasty: a diagnostic cohort study of 48 patients

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Hao; Yang, Dejin; Guo, Shengjie; Tang, Jing; Liu, Jian; Wang, Dacheng; Zhou, Yixin [Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Department of Orthopaedic Surgery, Beijing (China)

    2016-11-15

    For postoperative imaging assessment of cementless hip arthroplasty, radiography and computed tomography (CT) were restricted by overlapping structures and metal artifacts, respectively. A new tomosynthesis with metal artifact reduction (TMAR) is introduced by using metal extraction and ordered subset-expectation maximization (OS-EM) reconstruction. This study investigated the effectiveness of TMAR in assessing fixation stability of cementless hip arthroplasty components. We prospectively included 48 consecutive patients scheduled for revision hip arthroplasty in our hospital, with 41 femoral and 35 acetabular cementless components available for evaluation. All patients took the three examinations of radiography, CT, and TMAR preoperatively, with intraoperative mechanical tests, and absence or presence of osteointegration on retrieved prosthesis as reference standards. Three senior surgeons and four junior surgeons evaluated these images independently with uniform criteria. For TMAR, 82 % diagnoses on the femoral side and 84 % diagnoses on the acetabular side were accurate. The corresponding values were 44 and 67 % for radiography, and 39 % and 74 % for CT. Senior surgeons had significantly higher accuracy than junior surgeons by radiography (p < 0.05), but not by TMAR or CT. By minimizing metal artifacts in the bone-implant interface and clearly depicting peri-implant trabecular structures, the TMAR technique improved the diagnostic accuracy of assessing fixation stability of cementless hip arthroplasty, and shortened the learning curve of less experienced surgeons. Level II, diagnostic cohort study. (orig.)

  11. Outcome in design-specific comparisons between highly crosslinked and conventional polyethylene in total hip arthroplasty

    DEFF Research Database (Denmark)

    Johanson, Per-Erik; Furnes, Ove; Ivar Havelin, Leif

    2017-01-01

    assessed risk of revision for any reason and for aseptic loosening using Cox regression adjusted for age, sex, femoral head material and size, surgical approach, stem fixation, and presence of hydroxyapatite coating (uncemented cups). Results - The CPE version of the ZCA cup had a risk of revision for any...... for any reason and revision due to aseptic loosening and/or osteolysis. Patients and methods - Using the Nordic Arthroplasty Register Association (NARA) database, we identified cup and liner designs where either XLPE or CPE had been used in more than 500 THAs performed for primary hip osteoarthritis. We...

  12. Early experience with dual mobility acetabular systems featuring highly cross-linked polyethylene liners for primary hip arthroplasty in patients under fifty five years of age: an international multi-centre preliminary study.

    Science.gov (United States)

    Epinette, Jean-Alain; Harwin, Steven F; Rowan, Fiachra E; Tracol, Philippe; Mont, Michael A; Chughtai, Morad; Westrich, Geoffrey H

    2017-03-01

    To evaluate early performance of contemporary dual mobility acetabular systems with second generation annealed highly cross-linked polyethylene for primary hip arthroplasty of patients under 55 years of age. A prospective observational five years study across five centers in Europe and the USA of 321 patients with a mean age of 48.1 years was performed. Patients were assessed for causes of revision, hip instability, intra-prosthetic dissociation, Harris hip score and radiological signs of osteolysis. There were no dislocations and no intra-prosthetic dissociations. Kaplan Meier analysis demonstrated 97.51% survivorship for all cause revision and 99.68% survivorship for acetabular component revision at five years. Mean Harris hip score was 93.6. Two acetabular shells were revised for neck-rim implant impingement without dislocation and ten femoral stems were revised for causes unrelated to dual mobility implants. Contemporary highly cross-linked polyethylene dual mobility systems demonstrate excellent early clinical, radiological, and survivorship results in a cohort of patients that demand high performance from their implants. It is envisaged that DM and second generation annealed HXLPE may reduce THA instability and wear, the two most common causes of THA revision in hip arthroplasty.

  13. Metallic Modular Taper Junctions in Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Timothy McTighe

    2015-08-01

    Full Text Available The emergence of modularity in total hip arthroplasty (THA in the 1980s and 1990s was based on the fact that the benefit of these design features outweighed the risk. The use of metallic modular junctions presents a unique set of advantages and problems for use in THA. The advantages include improvement in fit and fill of the implant to bone, restoration of joint mechanics, reduced complications in revision surgery and reduction of costly inventory. However, the risks or concerns are a little harder to identify and deal with. Certainly corrosion, and fatigue failure are the two most prevalent concerns but now the specifics of fretting wear and corrosive wear increasing particulate debris and the potential biological response is having an impact on the design and potential longevity of the reconstructed hip. Material and designs are facing a shorter life expectancy than what was previously thought, mostly due to an increasing level of physical activity by the patient. Because there are no accurate laboratory test whereby the service life and performance of these implants can be predicted, early controlled clinical evaluations are necessary. Early publication of testing and clinical impressions should be encouraged in an attempt to reduce exposure to potential at risk patients, implants and material. The reduction and possible elimination of risks will require a balancing of all the variables requiring a multidisciplinary endeavor. This paper is designed to review the risk factors, and benefits of modular junctions in total hip arthroplasty (THA. Also some basic engineering principals that can reduce risk factors and improve functionality of modular junctions.

  14. Periacetabular Bone Mineral Density Changes After Resurfacing Hip Arthroplasty Versus Conventional Total Hip Arthroplasty. A Randomized Controlled DEXA Study

    NARCIS (Netherlands)

    Smolders, J.M.H.; Pakvis, D.F.; Hendrickx, B.W.; Verdonschot, Nicolaas Jacobus Joseph; van Susante, J.L.C.

    2013-01-01

    A randomized controlled trial was performed to evaluate acetabular bone mineral density (BMD) changes after hip resurfacing (RHA) versus an established conventional total hip arthroplasty (THA). A total of 71 patients were allocated randomly to receive either an RHA press-fit cobalt–chromium cup (n

  15. One-year incidence of prosthetic joint infection in total hip arthroplasty

    DEFF Research Database (Denmark)

    Gundtoft, P H; Pedersen, A B; Schønheyder, H C

    2017-01-01

    OBJECTIVE: To examine the trend of Prosthetic Joint Infections (PJI) following primary total hip arthroplasty (THA) and the antimicrobial resistance of the bacteria causing these infections. MATERIALS AND METHODS: We identified a population-based cohort of patients in the Danish Hip Arthroplasty...

  16. Bipolar hip arthroplasty for avascular necrosis of femoral head in young adults

    Science.gov (United States)

    Dudani, Baldev; Shyam, Ashok K; Arora, Pankush; Veigus, Arjun

    2015-01-01

    Background: Bipolar hip arthroplasty (BHA) is one of the options for treatment of avascular necrosis (AVN) of the femoral head. Acetabular erosion and groin pain are the most allowing for gross motion between the common complications. We propose that these complications are secondary to improper acetabular preparation allowing for motion between the BHA head and the acetabulum. Materials and Methods: The current study retrospectively evaluated patients’records from case files and also called them for clinical and radiological followup. 96 hips with AVN of the femoral head treated with BHA were included in the study. All patients were males with a mean age of 42 years (range 30-59 years). In all cases, the acetabulum was gently reamed till it became uniformly concentric to achieve tight fitting trial cup. Clinical followup using Harris hip score (HHS) and radiological study for cup migration were done at followup. Results: The mean followup was 7.52 years (range 4-16 years). The HHS significantly improved from a preoperative value of 39.3 (range, 54-30) to a postoperative value of 89.12 (range 74-96). According to HHS grades, the final outcome was excellent in 52 hips, good in 28 and fair in 16 hips. Hip and groin pain was reported in four hips (5%), but did not limit activity. Subsidence (less than 5 mm) of the femoral component was seen in 8 cases. Subgroup analysis showed patients with Ficat Stage 3 having better range of motion, but similar HHS as compared to Ficat Stage 4 patients. Conclusion: Bipolar hip arthroplasty (BHA) using tight fitting cup and acetabular reaming in AVN hip has a low incidence of groin pain, acetabular erosion and revision in midterm followup. Good outcome and mid term survival can be achieved irrespective of the Ficat Stage. PMID:26015634

  17. Evaluation of the Painful Dual Taper Modular Neck Stem Total Hip Arthroplasty: Do They All Require Revision?

    Science.gov (United States)

    Kwon, Young-Min

    2016-07-01

    Although dual taper modular-neck total hip arthroplasty (THA) design with additional neck-stem modularity has the potential to optimize hip biomechanical parameters by facilitating adjustments of leg length, femoral neck version and offset, there is increasing concern regarding this stem design as a result of the growing numbers of adverse local tissue reactions due to fretting and corrosion at the neck-stem taper junction. Implant factors such as taper cone angle, taper surface roughness, taper contact area, modular neck taper metallurgy, and femoral head size play important roles in influencing extent of taper corrosion. There should be a low threshold to conduct a systematic clinical evaluation of patients with dual-taper modular-neck stem THA using systematic risk stratification algorithms as early recognition and diagnosis will ensure prompt and appropriate treatment. Although specialized tests such as metal ion analysis and cross-sectional imaging modalities such as metal artifact reduction sequence magnetic resonance imaging (MARS MRI) are useful in optimizing clinical decision-making, overreliance on any single investigative tool in the clinical decision-making process for revision surgery should be avoided. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Are Bundled Payments a Viable Reimbursement Model for Revision Total Joint Arthroplasty?

    Science.gov (United States)

    Courtney, P Maxwell; Ashley, Blair S; Hume, Eric L; Kamath, Atul F

    2016-12-01

    Alternative payment models, such as the Centers for Medicare & Medicaid Services (CMS) Bundled Payment for Care Improvement (BPCI) initiative, aim to decrease overall costs for hip and knee arthroplasties. We asked: (1) Is there any difference in the CMS episode-of-care costs, hospital length of stay, and readmission rate from before and after implementation of our bundled-payment program? (2) Is there any difference in reimbursements and resource utilization between revision THA and TKA at our institution? (3) Are there any independent risk factors for patients with high costs who may not be appropriate for a bundled-payment system for revision total joint arthroplasty (TJA)? Between October 2013 and March 2015, 218 patients underwent revision TKA or THA in one health system. Two hundred seventeen patients were reviewed as part of this study, and one patient with hemophilia was excluded from the analysis as an outlier. Our institution began a BPCI program for revision TJA during this study period. Patients' procedures done before January 1, 2014 at one hospital and January 1, 2015 at another hospital were not included in the bundled-care arrangement (70 revision TKAs and 56 revision THAs), whereas 50 revision TKAs and 41 revision THAs were performed under the BPCI initiative. Patient demographics, medical comorbidities, episode-of-care reimbursement data derived directly from CMS, length of stay, and readmission proportions were compared between the bundled and nonbundled groups. Length of stay in the group that underwent surgery before the bundled-care arrangement was longer than for patients whose procedures were done under the BPCI (mean 4.02 [SD, 3.0 days] versus mean 5.27 days [SD, 3.6 days]; p = 0.001). Index hospitalization reimbursement for the bundled group was less than for the nonbundled group (mean USD 17,754 [SD, USD 2741] versus mean USD 18,316 [SD, USD 4732]; p = 0.030). There was no difference, with the numbers available, in total episode

  19. Probability and heritability estimates on primary osteoarthritis of the hip leading to total hip arthroplasty

    DEFF Research Database (Denmark)

    Skousgaard, Søren Glud; Hjelmborg, Jacob; Skytthe, Axel

    2015-01-01

    INTRODUCTION: Primary hip osteoarthritis, radiographic as well as symptomatic, is highly associated with increasing age in both genders. However, little is known about the mechanisms behind this, in particular if this increase is caused by genetic factors. This study examined the risk and heritab......INTRODUCTION: Primary hip osteoarthritis, radiographic as well as symptomatic, is highly associated with increasing age in both genders. However, little is known about the mechanisms behind this, in particular if this increase is caused by genetic factors. This study examined the risk...... and heritability of primary osteoarthritis of the hip leading to a total hip arthroplasty, and if this heritability increased with increasing age. METHODS: In a nationwide population-based follow-up study 118,788 twins from the Danish Twin Register and 90,007 individuals from the Danish Hip Arthroplasty Register...... not have had a total hip arthroplasty at the time of follow-up. RESULTS: There were 94,063 twins eligible for analyses, comprising 835 cases of 36 concordant and 763 discordant twin pairs. The probability increased particularly from 50 years of age. After sex and age adjustment a significant additive...

  20. Revision of failed hip resurfacing to total hip arthroplasty rapidly relieves pain and improves function in the early post operative period

    Directory of Open Access Journals (Sweden)

    Muirhead-Allwood Sarah K

    2010-11-01

    Full Text Available Abstract We reviewed the results of 25 consecutive patients who underwent revision of a hip resurfacing prosthesis to a total hip replacement. Revisions were performed for recurrent pain and effusion, infection and proximal femoral fractures. Both components were revised in 20 cases. There were 12 male and 13 female patients with average time to revision of 34.4 and 26.4 months respectively. The mean follow up period was 12.7 months (3 to 31. All patients reported relief of pain and excellent satisfaction scores. Two patients experienced stiffness up to three months post operatively. Pre operative Oxford, Harris and WOMAC hip scores were 39.1, 36.4 and 52.2 respectively. Mean post operative scores at last follow up were 17.4, 89.8 and 6.1 respectively (p

  1. Immunological Responses to Total Hip Arthroplasty.

    Science.gov (United States)

    Man, Kenny; Jiang, Lin-Hua; Foster, Richard; Yang, Xuebin B

    2017-08-01

    The use of total hip arthroplasties (THA) has been continuously rising to meet the demands of the increasingly ageing population. To date, this procedure has been highly successful in relieving pain and restoring the functionality of patients' joints, and has significantly improved their quality of life. However, these implants are expected to eventually fail after 15-25 years in situ due to slow progressive inflammatory responses at the bone-implant interface. Such inflammatory responses are primarily mediated by immune cells such as macrophages, triggered by implant wear particles. As a result, aseptic loosening is the main cause for revision surgery over the mid and long-term and is responsible for more than 70% of hip revisions. In some patients with a metal-on-metal (MoM) implant, metallic implant wear particles can give rise to metal sensitivity. Therefore, engineering biomaterials, which are immunologically inert or support the healing process, require an in-depth understanding of the host inflammatory and wound-healing response to implanted materials. This review discusses the immunological response initiated by biomaterials extensively used in THA, ultra-high-molecular-weight polyethylene (UHMWPE), cobalt chromium (CoCr), and alumina ceramics. The biological responses of these biomaterials in bulk and particulate forms are also discussed. In conclusion, the immunological responses to bulk and particulate biomaterials vary greatly depending on the implant material types, the size of particulate and its volume, and where the response to bulk forms of differing biomaterials are relatively acute and similar, while wear particles can initiate a variety of responses such as osteolysis, metal sensitivity, and so on.

  2. Economic analysis of two-stage septic revision after total hip arthroplasty: What are the relevant costs for the hospital's orthopedic department?

    Science.gov (United States)

    Kasch, R; Assmann, G; Merk, S; Barz, T; Melloh, M; Hofer, A; Merk, H; Flessa, S

    2016-03-01

    The number of septic total hip arthroplasty (THA) revisions is increasing continuously, placing a growing financial burden on hospitals. Orthopedic departments performing septic THA revisions have no basis for decision making regarding resource allocation as the costs of this procedure for the departments are unknown. It is widely assumed that septic THA procedures can only be performed at a loss for the department. Therefore, the purpose of this study was to investigate whether this assumption is true by performing a detailed analysis of the costs and revenues for two-stage septic THA revision. Patients who underwent revision THA for septic loosening in two sessions from January 2009 through March 2012 were included in this retrospective, consecutive cost study from the orthopedic department's point of view. We analyzed variable and case-fixed costs for septic revision THA with special regard to implantation and explantation stay. By using marginal costing approach we neglected hospital-fixed costs. Outcome measures include reimbursement and daily contribution margins. The average direct costs (reimbursement) incurred for septic two-stage revision THA was €10,828 (€24,201). The difference in cost and contribution margins per day was significant (p cost for septic revision THA performed in two sessions. Disregarding hospital-fixed costs the included variable and case fixed-costs were covered by revenues. This study provides cost data, which will be guidance for health care decision makers.

  3. Ileus following total hip or knee arthroplasty is associated with increased risk of deep venous thrombosis and pulmonary embolism.

    Science.gov (United States)

    Berend, Keith R; Lombardi, Adolph V; Mallory, Thomas H; Dodds, Kathleen L; Adams, Joanne B

    2004-10-01

    Venous thromboembolic disease (VTD), deep venous thrombosis and pulmonary embolism, causes morbidity and mortality following total hip and total knee arthroplasties, while ileus complicates up to 4.0%. The clinical courses of 2,949 patients undergoing 3,364 consecutive primary and revision total hip and total knee arthroplasties, radical debridements, and reimplantations at one institution over a 2-year period were reviewed to examine the relationship between ileus and VTD. VTD prophylaxis consisted of aspirin and intermittent plantar pulse boots for all patients except those at high risk, who received parenteral chemical prophylaxis and boots. Ileus occurred in 62 patients (2.1%) and symptomatic DVT in 51 (1.7%). With ileus, the incidence of DVT was 8.1%: odds ratio 5.5 (P =.0036). Symptomatic pulmonary embolism occurred in 7 patients (0.24%); with ileus the incidence was 3.2%: odds ratio 19.6 (P =.0082). A significant increase was observed in rates of VTD with ileus. We recommend using parenteral chemical and mechanical prophylaxis in patients with ileus following total hip and total knee arthroplasties.

  4. Nurses' responsibilities in postoperative pain management following total hip arthroplasty

    OpenAIRE

    Dumolard, Pierre; Gök, Mustafa; Le, Ngoc

    2017-01-01

    Total hip arthroplasty is the replacement of a hip joint that has been severely damaged. The operation is recommended if other treatments have not responded adequately. As the nurses are the professionals who spend the most time with patients after the surgery, they play an important role in the patient’s pain management. The aim of the thesis is to define the nurse’s responsibilities in the care of total hip arthroplasty. The purpose of the thesis is to analyze existing research, which may s...

  5. High-volume infiltration analgesia in bilateral hip arthroplasty

    DEFF Research Database (Denmark)

    Andersen, Lasse Ø; Otte, Niels Kristian Stahl; Husted, Henrik

    2011-01-01

    Background and purpose High-volume infiltration analgesia may be effective in postoperative pain management after hip arthroplasty but methodological problems prevent exact interpretation of previous studies. Methods In a randomized, double-blind placebo-controlled trial in 12 patients undergoing...... bilateral total hip arthroplasty (THA) in a fast-track setting, saline or high-volume (170 mL) ropivacaine (0.2%) with epinephrine (1:100,000) was administered to the wound intraoperatively along with supplementary postoperative injections via an intraarticular epidural catheter. Oral analgesia...... was instituted preoperatively with a multimodal regimen (gabapentin, celecoxib, and acetaminophen). Pain was assessed repeatedly for 48 hours postoperatively, at rest and with 45° hip flexion. Results Pain scores were low and similar between ropivacaine and saline administration. Median hospital stay was 4...

  6. Preliminary results of a randomized trial comparing 400 cGy vs 700 cGy as an adjuvant to prevent heterotopic ossification after total hip arthroplasty

    International Nuclear Information System (INIS)

    Nguyen, Cam; Gupta-Burt, Shalina; Silverton, Craig; Cummings, Marilyn; Galante, Jorge O.

    1997-01-01

    Purpose/Objective: We report our preliminary results of a randomized trial comparing one single dose of 400 cGy versus 700 cGy given postoperatively in an attempt to prevent heterotopic ossification after total hip arthroplasty. Materials and Methods: From 09/1993 and 05/1996, over 800 total hip replacements were performed at our hospital. From this group of patients, 120 hips in 114 high-risk patients (14%) were enrolled in a randomized trial to determine if 400 cGy (Group A) is as efficacious as 700 cGy (Group B) in preventing heterotopic ossification. In Group A, there were 42 males (46 hips) and 12 females (12 hips) with a mean age of 60 (range 41-79); with 18 primary cementless femoral components (33%), 30 primary cemented stems (55%) and 10 revisions. In Group B, there were 30 males (32 hips) and 30 females (31 hips) with a median age of 59 (range 41-85); with 12 primary cementless femoral components (20%), 44 primary cemented stems (73%) and 6 revisions. All acetabular components were of the cementless type. Patients were randomized to receive either 400 cGy or 700 cGy in one fraction. Radiotherapy is given within 48 hours post-operatively using paired anterior and posterior fields, with blocking of the cementless acetabular component and the femoral component. Results: All 114 patients were available for a minimum follow-up of 6 months (range 6-30 months). None of the arthroplasties has failed at the latest follow-up. There were no radiation therapy complications noted. Statistical analysis revealed no difference in the distribution of patients in either group according to age, sex, primary or revision arthroplasty, cemented or cementless femoral component fixation, preoperative heterotopic ossification risk, or surgical approach. Of the 58 hips in Group A, heterotopic ossification was graded as Grade 0 in 24 hips, Grade I in 10 hips, Grade II in 18 hips, Grade III in 6 hips, with no cases of Grade IV. Of the 63 hips in Group B, heterotopic ossification was

  7. Persistent non-specific FDG uptake on PET imaging following hip arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Zhuang, Hongming; Chacko, Thomas K.; Hickeson, Marc; Stevenson, Karen; Feng, Qi; Ponzo, Fabio; Alavi, Abass [Division of Nuclear Medicine, Department of Radiology, The Hospital of University of Pennsylvania, 110 Donner Building, 3400 Spruce Street, Philadelphia, PA 19104 (United States); Garino, Jonathan P. [Department of Orthopedic Surgery, The Hospital of University of Pennsylvania, Philadelphia, PA 19802 (United States)

    2002-10-01

    Hip arthroplasty is a common surgical procedure, but the diagnosis of infection associated with hip arthroplasty remains challenging. Fluorine-18 fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) has been shown to be a promising imaging modality in settings where infection is suspected. However, inflammatory reaction to surgery can result in increased FDG uptake at various anatomic locations, which may erroneously be interpreted as sites of infection. The purpose of this study was to assess the patterns and time course of FDG accumulation following total hip replacement over an extended period of time. Firstly, in a prospective study nine patients with total hip replacement were investigated to determine the patterns of FDG uptake over time. Three FDG-PET scans were performed in each patient at about 3, 6 and 12 months post arthroplasty. Secondly, in a retrospective analysis, the medical and surgical history and FDG-PET imaging results of 710 patients who had undergone whole-body scans for the evaluation of possible malignant disorders were reviewed. The history of arthroplasty and FDG-PET findings in the hip region were reviewed for this study. Patients with symptomatic arthroplasties or related complaints during FDG-PET scanning were excluded from the analysis. During the entire study period, all nine patients enrolled in the prospective study were demonstrated to have increased FDG uptake around the femoral head or neck portion of the prosthesis that extended to the soft tissues surrounding the femur. Among the patients reviewed in the retrospective study, 18 patients with a history of 21 hip arthroplasties who were asymptomatic at the time of FDG-PET scan met the criteria for inclusion. The time interval between the hip arthroplasty and the FDG-PET study ranged from 3 months to 288 months (mean{+-}SD: 80.4{+-}86.2 months). In 81% (17 of 21) of these prostheses, increased FDG uptake could be noted around the femoral head or neck portion of the

  8. Intellijoint HIP®: a 3D mini-optical navigation tool for improving intraoperative accuracy during total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Paprosky WG

    2016-11-01

    Full Text Available Wayne G Paprosky,1,2 Jeffrey M Muir3 1Department of Orthopedics, Section of Adult Joint Reconstruction, Department of Orthopedics, Rush University Medical Center, Rush–Presbyterian–St Luke’s Medical Center, Chicago, 2Central DuPage Hospital, Winfield, IL, USA; 3Intellijoint Surgical, Inc, Waterloo, ON, Canada Abstract: Total hip arthroplasty is an increasingly common procedure used to address degenerative changes in the hip joint due to osteoarthritis. Although generally associated with good results, among the challenges associated with hip arthroplasty are accurate measurement of biomechanical parameters such as leg length, offset, and cup position, discrepancies of which can lead to significant long-term consequences such as pain, instability, neurological deficits, dislocation, and revision surgery, as well as patient dissatisfaction and, increasingly, litigation. Current methods of managing these parameters are limited, with manual methods such as outriggers or calipers being used to monitor leg length; however, these are susceptible to small intraoperative changes in patient position and are therefore inaccurate. Computer-assisted navigation, while offering improved accuracy, is expensive and cumbersome, in addition to adding significantly to procedural time. To address the technological gap in hip arthroplasty, a new intraoperative navigation tool (Intellijoint HIP® has been developed. This innovative, 3D mini-optical navigation tool provides real-time, intraoperative data on leg length, offset, and cup position and allows for improved accuracy and precision in component selection and alignment. Benchtop and simulated clinical use testing have demonstrated excellent accuracy, with the navigation tool able to measure leg length and offset to within <1 mm and cup position to within <1° in both anteversion and inclination. This study describes the indications, procedural technique, and early accuracy results of the Intellijoint HIP

  9. Vibroacoustography for the assessment of total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Hermes A.S. Kamimura

    2013-04-01

    Full Text Available OBJECTIVES: This paper proposes imaging with 3-dimensional vibroacoustography for postoperatively assessing the uncovered cup area after total hip arthroplasty as a quantitative criterion to evaluate implant fixation. METHODS: A phantom with a bone-like structure covered by a tissue-mimicking material was used to simulate a total hip arthroplasty case. Vibroacoustography images of the uncovered cup region were generated using a two-element confocal ultrasound transducer and a hydrophone inside a water tank. Topological correction based on the geometry of the implant was performed to generate a 3-dimensional representation of the vibroacoustography image and to accurately evaluate the surface. The 3-dimensional area obtained by the vibroacoustography approach was compared to the area evaluated by a 3-dimensional motion capture system. RESULTS: The vibroacoustography technique provided high-resolution, high-contrast, and speckle-free images with less sensitivity to the beam incidence. Using a 3-dimensional-topology correction of the image, we accurately estimated the uncovered area of the implant with a relative error of 8.1% in comparison with the motion capture system measurements. CONCLUSION: Measurement of the cup coverage after total hip arthroplasty has not been well established; however, the covered surface area of the acetabular component is one of the most important prognostic factors. The preliminary results of this study show that vibroacoustography is a 3-dimensional approach that can be used to postoperatively evaluate total hip arthroplasty. The favorable results also provide an impetus for exploring vibroacoustography in other bone or implant surface imaging applications.

  10. The risk of venous thromboembolism with aspirin compared to anticoagulants after hip and knee arthroplasty.

    Science.gov (United States)

    Chu, Janet N; Maselli, Judith; Auerbach, Andrew D; Fang, Margaret C

    2017-07-01

    Recent guidelines include aspirin as an option to prevent venous thromboembolism (VTE) in selected patients undergoing hip or knee replacement surgery. However, the efficacy of aspirin after arthroplasty has not been well-defined, particularly in more contemporary patient populations. We compared rates of post-operative VTE between patients who received aspirin-only versus anticoagulants after hip or knee arthroplasty, using data from a large US-based administrative database. We conducted a retrospective cohort study of 231,780 adults who underwent total knee arthroplasty and 110,621 who underwent total hip arthroplasty in 2009-2012 and who received pharmacologic VTE prophylaxis (aspirin or anticoagulant) within the first 7days after surgery. We compared the risk of post-operative VTE between patients receiving aspirin-only vs. anticoagulants, controlling for clinical and hospital characteristics using multivariable logistic regression with propensity score adjustment. Aspirin-only prophylaxis was administered to 7.5% of patients after knee arthroplasty and 8.0% after hip arthroplasty. Post-operative VTE was diagnosed in 2217 (0.96%) patients after knee arthroplasty and 454 (0.41%) after hip arthroplasty. Compared to anticoagulants, aspirin was not associated with a higher risk for post-operative VTE either after knee arthroplasty (adjusted odds ratio and 95% confidence interval [OR] 0.34 [0.24-0.48]) or hip arthroplasty (OR 0.82 [0.45-1.51]). Aspirin was uncommonly administered as the sole prophylactic agent after hip or knee arthroplasty in this study. However, patients who received aspirin-only had similar rates of post-operative VTE compared to patients who received anticoagulants. Further research should focus on distinguishing which patients benefit more from anticoagulants versus aspirin after arthroplasty. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. A novel technique for impaction bone grafting in acetabular reconstruction of revision total hip arthroplasty using an ex vivo compaction device

    International Nuclear Information System (INIS)

    Akiyama, Haruhiko; Takemoto, Mitsuru; Morishima, Takkan

    2011-01-01

    Impaction bone grafting allows restoration of the acetabular bone stock in revision hip arthroplasty. The success of this technique depends largely on achieving adequate initial stability of the component. To obtain well-compacted, well-graded allograft aggregates, we developed an ex vivo compaction device to apply it in revision total hip arthroplasty on the acetabular side, and characterized mechanical properties and putative osteoconductivity of allograft aggregates. Morselized allograft bone chips were compacted ex vivo using the creep technique and subsequent impaction technique to form the bone aggregates. Impaction allograft reconstruction of the acetabulum using an ex vivo compaction device was performed on eight hips. The mechanical properties and three-dimensional micro-CT-based structural characteristics of the bone aggregates were investigated. In clinical practice, this technique offered good reproducibility in reconstructing the cavity and the segmental defects of the acetabulum, with no migration and no loosening of the component. In vitro analysis showed that the aggregates generated from 25 g fresh-frozen bone chips gained compression stiffness of 13.5-15.4 MPa under uniaxial consolidation strain. The recoil of the aggregates after compaction was 2.6-3.9%. The compression stiffness and the recoil did not differ significantly from those measured using a variety of proportions of large- and small-sized bone chips. Micro-CT-based structural analysis revealed average pore sizes of 268-299 μm and average throat diameter of pores in the bone aggregates of more than 100 μm. These sizes are desirable for osteoconduction, although large interconnected pores of more than 500 μm were detectable in association with the proportion of large-sized bone chips. Cement penetration into the aggregates was related to the proportion of large-sized bone chips. This study introduces the value of an ex vivo compaction device in bone graft compaction in clinical

  12. Cirrhosis is a risk factor for total hip arthroplasty for avascular necrosis

    DEFF Research Database (Denmark)

    Deleuran, Thomas; Overgaard, Søren; Vilstrup, Hendrik

    2016-01-01

    Background and purpose - There are limited data on risk factors for avascular necrosis of the hip, but cirrhosis has been proposed as a risk factor. We examined the association between cirrhosis and incidence of total hip arthroplasty for avascular necrosis. Methods - We used nationwide healthcare......,052 reference individuals. Their median age was 57 years, and 65% were men. 45 cirrhosis patients and 44 reference individuals underwent total hip arthroplasty for avascular necrosis. Cirrhosis patients' HR for a total hip arthroplasty for avascular necrosis was 10 (95% CI: 6-17), yet their 5-year risk...... of avascular necrosis was only 0.2%. For the reference individuals, the 5-year risk was 0.02%. Interpretation - Cirrhosis is a strong risk factor for avascular necrosis of the hip, but it is rare even in cirrhosis patients....

  13. Fatal Cobalt Toxicity after a Non-Metal-on-Metal Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Rinne M. Peters

    2017-01-01

    Full Text Available This case illustrates the potential for systemic cobalt toxicity in non-metal-on-metal bearings and its potentially devastating consequences. We present a 71-year-old male with grinding sensations in his right hip following ceramic-on-ceramic total hip arthroplasty (THA. After diagnosing a fractured ceramic liner, the hip prosthesis was revised into a metal-on-polyethylene bearing. At one year postoperatively, X-rays and MARS-MRI showed a fixed reversed hybrid THA, with periarticular densities, flattening of the femoral head component, and a pattern of periarticular metal wear debris and pseudotumor formation. Before revision could take place, the patient was admitted with the clinical picture of systemic cobalt toxicity, supported by excessively high serum cobalt and chromium levels, and ultimately died. At autopsy dilated cardiomyopathy as cause of death was hypothesized. A third body wear reaction between ceramic remnants and the metal femoral head very likely led to excessive metal wear, which contributed systemic cobalt toxicity leading to neurotoxicity and heart failure. This case emphasizes that fractured ceramic-on-ceramic bearings should be revised to ceramic-on-ceramic or ceramic-on-polyethylene bearings, but not to metal-on-polyethylene bearings. We aim to increase awareness among orthopedic surgeons for clinical clues for systemic cobalt intoxication, even when there is no metal-on-metal bearing surface.

  14. Short Operative Duration and Surgical Site Infection Risk in Hip and Knee Arthroplasty Procedures.

    Science.gov (United States)

    Dicks, Kristen V; Baker, Arthur W; Durkin, Michael J; Anderson, Deverick J; Moehring, Rebekah W; Chen, Luke F; Sexton, Daniel J; Weber, David J; Lewis, Sarah S

    2015-12-01

    To determine the association (1) between shorter operative duration and surgical site infection (SSI) and (2) between surgeon median operative duration and SSI risk among first-time hip and knee arthroplasties. Retrospective cohort study A total of 43 community hospitals located in the southeastern United States. Adults who developed SSIs according to National Healthcare Safety Network criteria within 365 days of first-time knee or hip arthroplasties performed between January 1, 2008 and December 31, 2012. Log-binomial regression models estimated the association (1) between operative duration and SSI outcome and (2) between surgeon median operative duration and SSI outcome. Hip and knee arthroplasties were evaluated in separate models. Each model was adjusted for American Society of Anesthesiology score and patient age. A total of 25,531 hip arthroplasties and 42,187 knee arthroplasties were included in the study. The risk of SSI in knee arthroplasties with an operative duration shorter than the 25th percentile was 0.40 times the risk of SSI in knee arthroplasties with an operative duration between the 25th and 75th percentile (risk ratio [RR], 0.40; 95% confidence interval [CI], 0.38-0.56; Poperative duration did not demonstrate significant association with SSI for hip arthroplasties (RR, 1.04; 95% CI, 0.79-1.37; P=.36). Knee arthroplasty surgeons with shorter median operative durations had a lower risk of SSI than surgeons with typical median operative durations (RR, 0.52; 95% CI, 0.43-0.64; Poperative durations were not associated with a higher SSI risk for knee or hip arthroplasty procedures in our analysis.

  15. Total hip arthroplasty for giant cell tumour.

    Directory of Open Access Journals (Sweden)

    Kulkarni S

    1996-07-01

    Full Text Available A 32 month follow up of an uncommon case of a Giant Cell Tumour affecting the proximal end of femur is presented. Following a wide excision, the hip was reconstructed using Charnley type of low friction total hip arthroplasty. At a 32 month review, there was no recurrence and the function was good.

  16. Aspirin or Rivaroxaban for VTE Prophylaxis after Hip or Knee Arthroplasty.

    Science.gov (United States)

    Anderson, David R; Dunbar, Michael; Murnaghan, John; Kahn, Susan R; Gross, Peter; Forsythe, Michael; Pelet, Stephane; Fisher, William; Belzile, Etienne; Dolan, Sean; Crowther, Mark; Bohm, Eric; MacDonald, Steven J; Gofton, Wade; Kim, Paul; Zukor, David; Pleasance, Susan; Andreou, Pantelis; Doucette, Steve; Theriault, Chris; Abianui, Abongnwen; Carrier, Marc; Kovacs, Michael J; Rodger, Marc A; Coyle, Doug; Wells, Philip S; Vendittoli, Pascal-Andre

    2018-02-22

    Clinical trials and meta-analyses have suggested that aspirin may be effective for the prevention of venous thromboembolism (proximal deep-vein thrombosis or pulmonary embolism) after total hip or total knee arthroplasty, but comparisons with direct oral anticoagulants are lacking for prophylaxis beyond hospital discharge. We performed a multicenter, double-blind, randomized, controlled trial involving patients who were undergoing total hip or knee arthroplasty. All the patients received once-daily oral rivaroxaban (10 mg) until postoperative day 5 and then were randomly assigned to continue rivaroxaban or switch to aspirin (81 mg daily) for an additional 9 days after total knee arthroplasty or for 30 days after total hip arthroplasty. Patients were followed for 90 days for symptomatic venous thromboembolism (the primary effectiveness outcome) and bleeding complications, including major or clinically relevant nonmajor bleeding (the primary safety outcome). A total of 3424 patients (1804 undergoing total hip arthroplasty and 1620 undergoing total knee arthroplasty) were enrolled in the trial. Venous thromboembolism occurred in 11 of 1707 patients (0.64%) in the aspirin group and in 12 of 1717 patients (0.70%) in the rivaroxaban group (difference, 0.06 percentage points; 95% confidence interval [CI], -0.55 to 0.66; Paspirin group and in 5 (0.29%) in the rivaroxaban group (difference, 0.18 percentage points; 95% CI, -0.65 to 0.29; P=0.42). Clinically important bleeding occurred in 22 patients (1.29%) in the aspirin group and in 17 (0.99%) in the rivaroxaban group (difference, 0.30 percentage points; 95% CI, -1.07 to 0.47; P=0.43). Among patients who received 5 days of rivaroxaban prophylaxis after total hip or total knee arthroplasty, extended prophylaxis with aspirin was not significantly different from rivaroxaban in the prevention of symptomatic venous thromboembolism. (Funded by the Canadian Institutes of Health Research; ClinicalTrials.gov number, NCT01720108 .).

  17. Changes in collagen metabolites in serum after cemented hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Joerring, S; Jensen, L T

    1993-01-01

    Markers of types I and III collagen turnover were measured in serial blood samples collected preoperatively and 60 days after surgery in 13 patients undergoing cemented total hip arthroplasty and 11 patients undergoing cemented total knee arthroplasty. The markers were the carboxyterminal extension....... We suggest that the changes in serum PICP and serum PIIINP reflect collagen formation in healing soft connective tissue 60 days after cemented hip or knee arthroplasty....

  18. FAST-TRACK HIP AND KNEE ARTHROPLASTY (LITERATURE REVIEW

    Directory of Open Access Journals (Sweden)

    A. M. Ageenko

    2017-01-01

    Full Text Available In the present paper the authors discuss the history of fast-track formation, its development and current status. Fast-track advantages in comparison to other rehabilitation options are analyzed. The focus is placed on methods of accelerated rehabilitation after total hip and knee arthroplasty in the leading European and American clinics. Fast-track protocols of surgical centers of Denmark and Hospital for special surgery in the US are described, factors that determine time of hospital stay after total hip and knee arthroplasty are considered, predictors of hospital stay and patients satisfaction after the surgery are examined. The paper reflects the results of the comparison of frequency of thromboembolic and other complications as well as readmission rate after traditional rehabilitation and after fast-track. The paper considers fast-track in bilateral total knee replacement. The authors conclude that further research on acceleration of rehabilitation and reduction of hospital stay after total hip and knee arthroplasty needs to be focused on the optimization of pain relief, especially after discharge, blood preservation techniques, supplementation of fluids loss and strengthening of muscles. Literature analysis demonstrated that the implementation of the Protocol for accelerated recovery after joint arthroplasty in Russia is at an insufficient level. Data of foreign multicenter studies during recent years indicate a high efficacy and safety of this technique in different groups of patients.

  19. The incidence of total hip arthroplasty after hip arthroscopy in osteoarthritic patients

    Directory of Open Access Journals (Sweden)

    Haviv Barak

    2010-07-01

    Full Text Available Abstract Objective To assess the incidence of total hip arthroplasty (THA in osteoarthritic patients who were treated by arthroscopic debridement and to evaluate factors that might influence the time interval from the first hip arthroscopy to THA. Design Retrospective clinical series Methods Follow-up data and surgical reports were retrieved from 564 records of osteoarthritic patients that have had hip arthroscopy between the years 2002 to 2009 with a mean follow-up time of 3.2 years (range, 1-6.4 years. The time interval between the first hip arthroscopy to THA was modelled as a function of patient age; level of cartilage damage; procedures performed and repeated arthroscopies with the use of multivariate regression analysis. Results Ninety (16% of all participants eventually required THA. The awaiting time from the first arthroscopy to a hip replacement was found to be longer in patients younger than 55 years and in a milder osteoarthritic stage. Patients that experienced repeated hip scopes had a longer time to THA than those with only a single procedure. Procedures performed concomitant with debridement and lavage did not affect the time interval to THA. Conclusions In our series of arthroscopic treatment of hip osteoarthritis, 16% required THA over a period of 7 years. Factors that influence the time to arthroplasty were age, degree of osteoarthritis and recurrent procedures.

  20. The incidence of total hip arthroplasty after hip arthroscopy in osteoarthritic patients

    Science.gov (United States)

    2010-01-01

    Objective To assess the incidence of total hip arthroplasty (THA) in osteoarthritic patients who were treated by arthroscopic debridement and to evaluate factors that might influence the time interval from the first hip arthroscopy to THA. Design Retrospective clinical series Methods Follow-up data and surgical reports were retrieved from 564 records of osteoarthritic patients that have had hip arthroscopy between the years 2002 to 2009 with a mean follow-up time of 3.2 years (range, 1-6.4 years). The time interval between the first hip arthroscopy to THA was modelled as a function of patient age; level of cartilage damage; procedures performed and repeated arthroscopies with the use of multivariate regression analysis. Results Ninety (16%) of all participants eventually required THA. The awaiting time from the first arthroscopy to a hip replacement was found to be longer in patients younger than 55 years and in a milder osteoarthritic stage. Patients that experienced repeated hip scopes had a longer time to THA than those with only a single procedure. Procedures performed concomitant with debridement and lavage did not affect the time interval to THA. Conclusions In our series of arthroscopic treatment of hip osteoarthritis, 16% required THA over a period of 7 years. Factors that influence the time to arthroplasty were age, degree of osteoarthritis and recurrent procedures. PMID:20670440

  1. Cirrhosis is a risk factor for total hip arthroplasty for avascular necrosis.

    Science.gov (United States)

    Deleuran, Thomas; Overgaard, Søren; Vilstrup, Hendrik; Jepsen, Peter

    2016-06-01

    Background and purpose - There are limited data on risk factors for avascular necrosis of the hip, but cirrhosis has been proposed as a risk factor. We examined the association between cirrhosis and incidence of total hip arthroplasty for avascular necrosis. Methods - We used nationwide healthcare data to identify all Danish residents diagnosed with cirrhosis in 1994-2011, and matched them 1:5 by age and sex to non-cirrhotic reference individuals from the general population. We excluded people with a previous total hip arthroplasty, a previous hip fracture, or a previous diagnosis of avascular necrosis. We used stratified Cox regression to estimate the hazard ratio (HR) for cirrhosis patients relative to reference individuals, adjusting for potential confounders. We used the cumulative incidence function to compute 5-year risks. Results - We included 25,421 cirrhosis patients and 114,052 reference individuals. Their median age was 57 years, and 65% were men. 45 cirrhosis patients and 44 reference individuals underwent total hip arthroplasty for avascular necrosis. Cirrhosis patients' HR for a total hip arthroplasty for avascular necrosis was 10 (95% CI: 6-17), yet their 5-year risk of avascular necrosis was only 0.2%. For the reference individuals, the 5-year risk was 0.02%. Interpretation - Cirrhosis is a strong risk factor for avascular necrosis of the hip, but it is rare even in cirrhosis patients.

  2. Revision of infected knee arthroplasties in Denmark

    DEFF Research Database (Denmark)

    Lindberg-Larsen, Martin; Jørgensen, Christoffer C; Bagger, Jens

    2016-01-01

    Background and purpose - The surgical treatment of periprosthetic knee infection is generally either a partial revision procedure (open debridement and exchange of the tibial insert) or a 2-stage exchange arthroplasty procedure. We describe the failure rates of these procedures on a nationwide...... basis. Patients and methods - 105 partial revisions (100 patients) and 215 potential 2-stage revision procedures (205 patients) performed due to infection from July 1, 2011 to June 30, 2013 were identified from the Danish Knee Arthroplasty Register (DKR). Failure was defined as surgically related death...

  3. Editorial Commentary: Hip Arthroscopy Plays a Role in Painful Hip Resurfacing Arthroplasty but a Prearthroscopy Diagnosis Is Critical to Outcome.

    Science.gov (United States)

    Rossi, Michael J

    2016-03-01

    Whereas hip arthroscopy plays a role in the investigation and treatment of the painful hip resurfacing arthroplasty, a diagnosis before arthroscopy is critical to improved outcome. The rate of conversion to total hip arthroplasty jumps from 7% to 37% when a pre-arthroscopy diagnosis is not known. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  4. Total hip arthroplasty in Jesenice General hospital 1985–2006 – what has been done and look forward

    Directory of Open Access Journals (Sweden)

    Tomaž Silvester

    2007-11-01

    Full Text Available Background: Total arthroplasty is one of the most interesting and fast developing fields in orthopaedic surgery. Practically every joint in the human body is involved, total hip arthroplasties (THA being most frequent and with the longest history. Information on long-term results and survival of different types of prosthesis is invaluable for both patients and surgeons.Patients and methods: Between 1985 and 2006 there were 1563 THAs performed in Jesenice General Hospital. Average age at the time of operation was 67 years, almost two thirds of patients were women. The reason for operation was in 72 % idiopathic arthrosis and in 14 % sequaele of dysplasia.Results: There were 1370 primary procedures and 193 revisions (12.6 %. Aseptic loosening of the implant was the most frequent reason for revision (74 % and infection was observed in 1.5 %. In the first ten years of this research hybrid type of prosthesis was most frequently used, but nowadays, non-cemented prosthesis is used in majority of cases.Conclusions: Total hip arthroplasty is well established procedure at the Jesenice General Hospital. It considerably improves quality of life of the patient, for both, short- and long term, results are very good. New minimal invasive surgical techniques make postoperative rehabilitation faster and easier. The Register of prosthesis enables us to regularly analyze the results and provides treatment outcome information concerning the choice of prosthesis and the optimal surgical technique. Jesenice General Hospital is well recognized as one of the centers for arthroplasties in our country.

  5. Early results of metal on metal articulation total hip arthroplasty in young patients.

    Science.gov (United States)

    Mohamad, J A; Kwan, M K; Merican, A M; Abbas, A A; Kamari, Z H; Hisa, M K; Ismail, Z; Idrus, R M

    2004-12-01

    We report our early experience of 20 cases of metal on metal articulation total hip arthroplasty in 19 young patients. Avascular necrosis of the femoral head (63%) was the commonest diagnosis for patients undergoing this procedure, followed by osteoarthritis (21%). In general, most of the patients were young and physically active with an average age of 43.1 years (range, 25 to 58 years). The average follow-up period was 18 months (range, 7 to 46 months). The mean total Harris Hip Score preoperatively and at final follow-up was 31 points and 89 points respectively. The mean total Pain Score improved from an average of 11.5 to 41.1 points at final follow-up. Sixteen (84%) of the patients had a good to excellent hip score. There was one dislocation, which stabilized after reduction and conservative management. One case of early infection underwent a two-staged revision.

  6. Comparison between the Harris- and Oxford Hip Score to evaluate outcomes one-year after total hip arthroplasty

    NARCIS (Netherlands)

    Weel, Hanneke; Lindeboom, Robert; Kuipers, Sander E.; Vervest, Ton M. J. S.

    2017-01-01

    Harris Hip Score (HHS) is a surgeon administered measurement for assessing hip function before and after total hip arthroplasties (THA). Patient reported outcome measurements (PROMs) such as the Oxford Hip Score (OHS) are increasingly used. HHS was compaired to the OHS assessing whether the HHS can

  7. Unconstrained tripolar implants for primary total hip arthroplasty in patients at risk for dislocation.

    Science.gov (United States)

    Guyen, Olivier; Pibarot, Vincent; Vaz, Gualter; Chevillotte, Christophe; Carret, Jean-Paul; Bejui-Hugues, Jacques

    2007-09-01

    We performed a retrospective study on 167 primary total hip arthroplasty (THA) procedures in 163 patients at high risk for instability to assess the reliability of unconstrained tripolar implants (press-fit outer metal shell articulating a bipolar polyethylene component) in preventing dislocations. Eighty-four percent of the patients had at least 2 risk factors for dislocation. The mean follow-up length was 40.2 months. No dislocation was observed. Harris hip scores improved significantly. Six hips were revised, and no aseptic loosening of the cup was observed. The tripolar implant was extremely successful in achieving stability. However, because of the current lack of data documenting polyethylene wear at additional bearing, the routine use of tripolar implants in primary THA is discouraged and should be considered at the present time only for selected patients at high risk for dislocation and with limited activities.

  8. Digital subtraction arthrography in preoperative evaluation of painful total hip arthroplasty

    International Nuclear Information System (INIS)

    Ginai, A.Z.; Biezen, F.C. van; Kint, P.A.M.; Oei, H.Y.; Hop, W.C.J.

    1996-01-01

    Digital subtraction arthrograms, scintigrams and plain radiographs of 70 consecutive patients who underwent revision hip arthroplasty were scored individually and in masked fashion for the presence or absence of features indicating loosening of femoral and/or acetabular components. The operative findings acted as the gold standard. Digital subtraction arthrography was best for predicting a loose acetabular component, while no significant additional predictive value was found for plain radiographs and scintigraphy. Digital subtraction arthrography was also the most important modality for predicting a loose femoral component, while the plain radiograph was of significant additional value and scintigraphy was of no additional value on multivariate analysis. (orig./MG)

  9. Results of hip arthroplasty using Paavilainen technique in patients with congenitally dislocated hip

    Directory of Open Access Journals (Sweden)

    R. M. Tikhilov

    2014-01-01

    Full Text Available The purpose of the study was to analyze the medium- and long-term results of hip arthroplasty using Paavilainen technique in patients with the congenitally dislocated hip. Methods: From 2001 to 2012 180 operations were carried out were using the Paavilainen technique in 140 patients with high dislocation of the hip (Crowe IV. All patients were clinically evaluated using the Harris Hip Score (HHS, VAS and radiography. Statistical analysis was performed using the Pearson correlation coefficients, multiple regression analysis and classification trees analysis. Results: The average Harris score improved from preoperative 41.6 (40,3-43,5 to 79.3 (77,9-82,7 at final follow-up, and the difference was significant. Early complications were 9% (the most frequent were fractures of the proximal femur, later - 16.7% (pseudoarthrosis of the greater trochanter, 13.9%; disclocations-1,1%, aseptic loosening of the components - 1.7%, reoperation performed in 8.3% of cases. Such factors as age and limb length has statistically significant effect on functional outcomes. Established predictive model allows to get the best possible functional outcome in such patients with severe dysplasia. Conclusions: Total Hip arthroplasty using the Paavilainen technique is an effective method of surgical treatment in patients with the congenitally dislocated hip, but it is technically difficult operation with a high incidence of complications in comparison with standard primary total hip replacement.

  10. Preoperative prediction of potentially preventable morbidity after fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Jørgensen, Christoffer C; Petersen, Morten Aa; Kehlet, Henrik

    2016-01-01

    . DESIGN: Prospective observational study. SETTING: Elective primary unilateral total hip and knee arthroplasty with prospectively collected preoperative patient characteristics; similar standardised fast-track protocols; evaluation of complications through discharge and medical records; and complete 90...... days follow-up through nationwide databases. PARTICIPANTS: 8373 consecutive unselected total hip arthroplasty (THA) and knee arthroplasty from January 2010 to November 2012. RESULTS: There were 557 procedures (6.4%) followed by potentially preventable complications resulting in hospitalisation >4 days...

  11. Lunar phase does not influence perioperative complications in total hip arthroplasty.

    Science.gov (United States)

    Ficklscherer, Andreas; Angermann, Alexander; Weber, Patrick; Wegener, Bernd; Pietschmann, Matthias; Müller, Peter

    2012-02-29

    Lunar calendars, publishing recommendations for daily life, are gaining more and more attention in Germany, where 10.5% of the population believe in lunar effects on disease. A widespread and often heard belief is that a full moon has the most negative effects on surgical outcome. The present study evaluates the effects of lunar phase on perioperative complications in total hip arthroplasty. We performed a retrospective study with 305 patients being provided with a primary hip arthroplasty. To identify possible influences of the lunar phase on perioperative complications we investigated data such as operation length, blood loss and course of C-reactive protein that were collected during the patients' stay in the hospital and allocated them to moon illumination. There were no significant differences in all collected data concerning the lunar phase (p > 0.05). Although not statistically significant, there were fewer operations during the full moon phase. Therefore there is no evidence that lunar phase has an effect on perioperative complications in total hip arthroplasty. Fewer, though not significantly fewer, operations were performed during the full moon phase. Although this was not a prospective randomized trial, the statistical magnitude of the results does not support any recommendations for scheduling patients for total hip arthroplasty at any particular day of the lunar phase.

  12. Total Hip Arthroplasty Loosening Due to Mycobacterium Tuberculosis: A Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Anis Tebourbi

    2017-04-01

    Full Text Available Context: Prosthetic joint infection due to Mycobacterium tuberculosis with no previous history of pulmonary or extra pulmonary tuberculosis is an extremely rare complication. Aims To report the case of a patient with tuberculous mycobacterial prosthetic hip infection, 14 years after surgery for post traumatic osteoarthritis, with no previous history of tuberculosis. Methods A 46-year-old male presented an acetabular loosening of a cemented total hip arthroplasty with subnormal biologic parameters. A one stage revision surgery was planned. Intraoperative findings suggested mycobacterial tuberculous infection with presence of periacetabular yellowish rice-shaped granules. Results A one-stage prosthesis exchange was performed; Culture on Löwenstein-Jensen medium grew MTB days after inoculation and histological examination confirmed tuberculous infection. Patient was treated by antituberculous agents for 12 months with optimal clinical and biological response and no prosthetic loosening signs at eighteen months follow up. Conclusions Total hip arthroplasty loosening due to mycobacterium tuberculosis is a rare entity, which should be evoked even when no inflammatory signs are shown. Discovery of yellowish rice-shaped granules is an indicator to investigate for tuberculosis. Management of prosthetic joint infection due to M.tuberculosis must involve both medical and surgical approach.

  13. Hemorrhagic iliopsoas bursitis complicating well-functioning ceramic-on-ceramic total hip arthroplasty.

    Science.gov (United States)

    Park, Kyung Soon; Diwanji, Sanket R; Kim, Hyung Keun; Song, Eun Kyoo; Yoon, Taek Rim

    2009-08-01

    Iliopsoas bursitis has been increasingly recognized as a complication of total hip arthroplasty and is usually associated with polyethylene wear. Here, the authors report a case of hemorrhagic iliopsoas bursitis complicating an otherwise well-functioning ceramic-on-ceramic arthroplasty performed by minimal invasive modified 2-incision technique. The bursitis in turn resulted in femoral nerve palsy and femoral vein compression. In this report, there was no evidence to support that the bursitis was due to an inflammatory response to ceramic wear particles or any other wear particles originating from the total hip arthroplasty.

  14. Pre-operative ambulatory measurement of asymmetric leg loading during sit to stand in hip arthroplasty patients

    NARCIS (Netherlands)

    Martínez-Ramírez, Alicia; Weenk, D.; Lecumberri, Pablo; Verdonschot, Nicolaas Jacobus Joseph; Pakvis, Dean; Veltink, Petrus H.

    Total hip arthroplasty is a successful surgical procedure to treat patients with hip osteoarthritis. Clinicians use different questionnaires to evaluate these patients. Gait velocity and these questionnaires; usually show significant improvement after total hip arthroplasty. This clinical evaluation

  15. Mid-term results of the BIOLOX delta ceramic-on-ceramic total hip arthroplasty.

    Science.gov (United States)

    Lee, Y K; Ha, Y C; Yoo, J-I; Jo, W L; Kim, K-C; Koo, K H

    2017-06-01

    We conducted a prospective study of a delta ceramic total hip arthroplasty (THA) to determine the rate of ceramic fracture, to characterise post-operative noise, and to evaluate the mid-term results and survivorship. Between March 2009 and March 2011, 274 patients (310 hips) underwent cementless THA using a delta ceramic femoral head and liner. At each follow-up, clinical and radiological outcomes were recorded. A Kaplan-Meier analysis was undertaken to estimate survival. Four patients (four hips) died and 18 patients (20 hips) were lost to follow-up within five years. The remaining 252 patients (286 hips) were followed for a mean of 66.5 months (60 to 84). There were 144 men (166 hips) and 108 women (120 hips) with a mean age of 49.7 years (16 to 83) at surgery. The mean pre-operative Harris Hip Score of 47.1 points improved to 93.8 points at final follow-up. Six patients reported squeaking in seven hips; however, none were audible. Radiolucent lines involving Gruen zones one and/or seven were seen in 52 hips (18.2%). No hip had detectable wear, focal osteolysis or signs of loosening. One hip was revised because of fracture of the ceramic liner, which occurred due to an undetected malseating of the ceramic liner at the time of surgery. One hip was revised for a periprosthetic fracture of the femur, and one hip was treated for periprosthetic joint infection. The six-year survivorship with re-operation for any reason as the endpoint was 99.0% (95% confidence interval 97.8% to 100%). The rate of delta ceramic fracture was 0.3% (one of 286). While ceramic head fracture was dominant in previous ceramic-on-ceramic THA, fracture of the delta ceramic liner due to malseating is a concern. Cite this article: Bone Joint J 2017;99-B:741-8. ©2017 The British Editorial Society of Bone & Joint Surgery.

  16. Bone mineral density of the femoral neck in resurfacing hip arthroplasty

    DEFF Research Database (Denmark)

    Penny, Jeannette Østergaard; Ovesen, Ole; Brixen, Kim

    2010-01-01

    Resurfacing total hip arthroplasty (RTHA) may preserve the femoral neck bone stock postoperatively. Bone mineral density (BMD) may be affected by the hip position, which might bias longitudinal studies. We investigated the dependency of BMD precision on type of ROI and hip position....

  17. Allogenic blood transfusion following total hip arthroplasty: results from the nationwide inpatient sample, 2000 to 2009.

    Science.gov (United States)

    Saleh, Anas; Small, Travis; Chandran Pillai, Aiswarya Lekshmi Pillai; Schiltz, Nicholas K; Klika, Alison K; Barsoum, Wael K

    2014-09-17

    The large-scale utilization of allogenic blood transfusion and its associated outcomes have been described in critically ill patients and those undergoing high-risk cardiac surgery but not in patients undergoing elective total hip arthroplasty. The objective of this study was to determine the trends in utilization and outcomes of allogenic blood transfusion in patients undergoing primary total hip arthroplasty in the United States from 2000 to 2009. An observational cohort of 2,087,423 patients who underwent primary total hip arthroplasty from 2000 to 2009 was identified in the Nationwide Inpatient Sample. International Classification of Diseases, Ninth Revision, Clinical Modification procedure codes 99.03 and 99.04 were used to identify patients who received allogenic blood products during their hospital stay. Risk factors for allogenic transfusions were identified with use of multivariable logistic regression models. We used propensity score matching to estimate the adjusted association between transfusion and surgical outcomes. The rate of allogenic blood transfusion increased from 11.8% in 2000 to 19.0% in 2009. Patient-related risk factors for receiving an allogenic blood transfusion include an older age, female sex, black race, and Medicaid insurance. Hospital-related risk factors include rural location, smaller size, and non-academic status. After adjusting for confounders, allogenic blood transfusion was associated with a longer hospital stay (0.58 ± 0.02 day; p conservation methods. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.

  18. Femoral component loosening after hip resurfacing arthroplasty

    International Nuclear Information System (INIS)

    Zustin, Jozef; Sauter, Guido; Hahn, Michael; Morlock, Michael M.; Ruether, Wolfgang; Amling, Michael

    2010-01-01

    Before the re-introduction of the current generation of total hip resurfacing arthroplasty, component loosening and osteolysis were of great concern to the orthopaedic community. Early, mid- and long-term clinical results are encouraging, but component loosening still exists. Macroscopic, contact radiographic and histopathological analyses after undecalcified preparation of bone tissue specimens were performed. To investigate the frequency and morphological patterns of the loosening of the femoral component, we analysed a series of 190 retrieved femoral remnants that were revised for aseptic failures. Thirty-five (18.4%) hips were revised for clinical and/or radiographic loosening of the femoral component. Pseudoarthrosis (n = 17; median in situ time: 16 weeks, interquartile range [IQR]: 9 to 34), collapsed osteonecrosis (n = 5; median in situ time: 79 weeks, IQR: 63 to 97), cement-socket debonding (n = 3; median in situ time: 89 weeks, IQR: 54 to 97) and at later follow-up bone-cement loosening (n = 10; median in situ time: 175 weeks; IQR 112 to 198; p =0.005) were distinct patterns of the femoral remnant-implant loosening. Fibrocartilaginous metaplasia of interface bone trabeculae (n = 38; median in situ time: 61 weeks, IQR: 32 to 138) was strongly associated with femoral component loosening (p = 0.009). Both the trabecular hyperosteoidosis (n = 32; median in situ time: 71 weeks, IQR 50 to 129) and excessive intraosseous lymphocyte infiltration (n = 12; median in situ time: 75 weeks, IQR 51 to 98) at the bone-cement interface correlated strongly with fibrocartilaginous metaplasia (p = 0.001 and p = 0.016 respectively) and all three lesions were associated with the female gender (p = 0.021, p = 0.009, and p = 0.051). Femoral component loosening at early follow-up was mostly caused by pathological changes of the femoral remnant bone tissue: pseudoarthrosis and collapsed osteonecrosis. Fibrocartilaginous metaplasia was frequently observed in hips with femoral

  19. The innovation trap: modular neck in total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Samo Karel Fokter

    2017-04-01

    Full Text Available Background: Innovations play the key role in the success of orthopaedic surgery. However, even minor modifications in the established concepts and proven designs may result in disasters. The endemic of modular femoral neck fracture (24 cases of about 4000 implanted in fully modular total hip arthroplasty, popular in our country for the last 20 years, seems to challenge us with such an unfortunate consequences. The aim of this report was to analyze the extent and the causes of the problem on the one hand and to propose possible solutions on the other.Methods: Literature search for problems associated with Profemur Z (or earlier versions with the same taper-cone design fully-modular femoral stem made of titanium alloy (Ti6Al4V was performed, and hip arthroplasty registries were searched to evaluate the failure rates of the mentioned design. Mechanisms of failure were studied to get in-depth understanding of this particular hip reconstruction device.Results: Since 2010 onwards, several case reports on catastrophic modular femoral neck fractures of Profemur Z were published. Te frst Slovenian case was described in 2012. The first two larger series with modular femoral neck fractures were published in 2016. Te Australian Joint Replacement Registry was the first to discover increased revision rates due to fractures of this hip reconstruction system. Public Agency of the Republic of Slovenia for Medicinal Products and Medical Devices (JAZMP received frst two reports regarding Profemur Z modular neck complication from abroad in 2010, the first Slovenian report was received in 2012, and altogether 7 reports from Slovenian hospitals were received until December 2016. Corrosion at the neck-taper interface, where two equal or different materials are subject to constant wear in the presence of body fluids, is assumed to be responsible for the unacceptable high failure rate.Conclusions: Manufacturers are responsible to produce and market only safe devices

  20. Eradication of multidrug-resistant Acinetobacter baumannii in a female patient with total hip arthroplasty, with debridement and retention: a case report

    Directory of Open Access Journals (Sweden)

    Beieler Alison M

    2009-02-01

    Full Text Available Abstract Introduction Multidrug-resistant Acinetobacter baumannii has become a significant cause of healthcare-associated infections, but few reports have addressed Acinetobacter baumannii infections associated with orthopedic devices. The current recommended treatment for complicated infections due to orthopedic devices, including resistant gram-negative rods, consists of antimicrobial therapy with debridement and removal of implants. Case presentation The patient, a 47-year-old woman, had previously had a prior total hip arthroplasty at 16 years of age for a complex femoral neck fracture, and multiple subsequent revisions. This time, she underwent a fifth revision secondary to pain. Surgery was complicated by hypotension resulting in transfer to the intensive care unit and prolonged respiratory failure. She received peri-operative cefazolin but postoperatively developed surgical wound drainage requiring debridement of a hematoma. Cultures of this grew ampicillin-sensitive Enterococcus and Acinetobacter baumannii (sensitive only to amikacin and imipenem. The patient was started on imipenem. Removal of the total hip arthroplasty was not recommended because of the recent surgical complications, and the patient was eventually discharged home. She was seen weekly for laboratory tests and examinations and, after 4 months of therapy, the imipenem was discontinued. She did well clinically for 7 months before recurrent pain led to removal of the total hip arthroplasty. Intra-operative cultures grew ampicillin-sensitive Enterococcus and coagulase-negative Staphylococcus but no multidrug-resistant Acinetobacter baumannii. The patient received ampicillin for 8 weeks and had not had recurrent infection at the time of writing, 37 months after discontinuing imipenem. Conclusion We describe the successful treatment of an acute infection from multidrug-resistant Acinetobacter baumannii with debridement and retention of the total hip arthroplasty, using

  1. Ankylosing Spondylitis Increases Perioperative and Postoperative Complications After Total Hip Arthroplasty.

    Science.gov (United States)

    Blizzard, Daniel J; Penrose, Colin T; Sheets, Charles Z; Seyler, Thorsten M; Bolognesi, Michael P; Brown, Christopher R

    2017-08-01

    Ankylosing spondylitis (AS) is a chronic autoimmune spondyloarthropathy that primarily affects the axial spine and hips. Progressive disease leads to pronounced spinal kyphosis, positive sagittal balance, and altered biomechanics. The purpose of this study is to determine the complication profile of patients with AS undergoing total hip arthroplasty (THA). The Medicare sample was searched from 2005 to 2012 yielding 1006 patients with AS who subsequently underwent THA. Risk ratios (RRs) with 95% confidence intervals (CIs) were calculated for 90-day, 2-year, and the final postoperative follow-up for complications including hip dislocation, periprosthetic fracture, wound complication, revision THA, and postoperative infection. Compared to controls, AS patients had an RR of 2.50 (CI, 1.04-5.99) of THA component breakage at 90-days post-operatively and 1.99 (CI, 1.10-3.59) at 2-years. The RR of periprosthetic hip dislocation was elevated at 90 days (1.44; CI, 0.93-2.22) and significantly increased at 2-years (1.67; CI, 1.25-2.23) and overall follow-up (1.49; CI, 1.14-1.93). Similarly, the RR for THA revision was elevated at 90-days (1.46; CI, 0.97-2.18) and significantly increased at 2-years (1.69; CI, 1.33-2.14) and overall follow-up (1.51; CI, 1.23-1.85). Patients with AS are at increased risk for complications after THA. Altered biomechanics from a rigid, kyphotic spine place increased demand on the hip joints. The elevated perioperative and postoperative risks should be discussed preoperatively, and these patients may require increased preoperative medical optimization as well as possible changes in component selection and position to compensate for altered spinopelvic biomechanics. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Prevention of venous thromboembolic disease after total hip and knee arthroplasty.

    Science.gov (United States)

    Lieberman, Jay R; Hsu, Wellington K

    2005-09-01

    Patients undergoing total hip and knee arthroplasty are at increased risk for the development of venous thromboembolic disease, and there is general agreement that these patients require prophylaxis. The selection of a prophylactic agent involves a balance between efficacy and safety and often needs to be individualized for specific patients and institutions. Despite extensive research, the ideal agent for prophylaxis against deep venous thrombosis has not been identified. The results of randomized trials indicate that low-molecular-weight heparin, warfarin, and fondaparinux are the most effective prophylactic agents after total hip arthroplasty and that low-molecular-weight heparin, warfarin, fondaparinux, and pneumatic compression boots are the most effective agents after total knee arthroplasty. The duration of prophylaxis against deep venous thrombosis after total hip and knee arthroplasty remains controversial. Prophylaxis should be continued beyond hospital discharge. In the future, the determination of the duration of prophylaxis will be based on the risk stratification of individual patients. The practice of discharging patients from the hospital without prophylaxis, even when the decision is based on negative results of procedures that screen for the presence of deep venous thrombosis, is not cost-effective.

  3. Trochantoplasty for Total Hip Arthroplasty in Patients With Coxa Vara Deformity.

    Science.gov (United States)

    Yoo, Jun-Il; Parvizi, Javad; Song, Ji-Ung; Ha, Yong-Chan; Lee, Young-Kyun; Koo, Kyung-Hoi

    2017-07-01

    In total hip arthroplasty (THA) of hips with coxa vara, the femoral stems might be inserted in a varus alignment. To avoid varus insertion, we designed a technique, which we termed "trochantoplasty." In this procedure, the medial half of the greater trochanter was removed during THA. We evaluated 30 patients (31 hips) who had coxa vara deformity and underwent THA using trochantoplasty at the mean follow-up of 5 years (range, 3-9 years). All stems were inserted in the neutral position. One Vancouver type 1 periprosthetic femoral fracture occurred after a fall at postoperative 2 months. At the latest follow-up, the mean power of abductor was 4.3 (range, 3-5). Four patients had moderate limp whereas 26 patients had slight limp. The abduction at 90° flexion ranged from 15° to 45° (mean, 35°). There was no revision. All prostheses had bone-ingrown stability without any detectable wear or osteolysis. The mean Harris hip score was improved from 66.9 to 89.4 points. Trochantoplasty can be used to avoid varus insertion of the femoral stem while performing THA in patients with coxa vara deformity without compromising the abductor mechanism. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Operative Trends in the Treatment of Hip Fractures and the Role of Arthroplasty

    Science.gov (United States)

    Grau, Luis; Summers, Spencer; Rosas, Samuel; Ong, Alvin; Hernandez, Victor Hugo

    2018-01-01

    Introduction: There is a projected exponential increase in the number of hip fractures in the United States. Trends in patient demographics and the role of total hip arthroplasty (THA) and its associated outcomes following hip fractures surgery have not been well studied. Methods: Patients with proximal femur fractures between 1990 and 2007 were identified in the National Hospital Discharge Survey database. Demographics, comorbidities, perioperative complications, and discharge status for patients undergoing THA, hemiarthroplasty, or internal fixation were examined. Multivariable regression was performed to determine independent risk factors for perioperative complications. Results: Between 1990 and 2007, there was a statistically significant increase in patient age, adverse events, medical comorbidities, surgical complications, medical complications, and nonroutine discharge across all surgical treatment modalities. In the same time period, the utilization of THA for all fracture types decreased significantly. Discussion: Total hip arthroplasty was found to be an independent risk factor for perioperative complications. Orthopedic surgeons should be aware that the hip fracture population continues to get older, with more medical comorbidities and are at higher risk for perioperative complications. Conclusion: Total hip arthroplasty is associated with a higher rate of perioperative complications in the hip fracture population. PMID:29619275

  5. Identification of bacteria on the surface of clinically infected and non-infected prosthetic hip joints removed during revision arthroplasties by 16S rRNA gene sequencing and by microbiological culture

    Science.gov (United States)

    Dempsey, Kate E; Riggio, Marcello P; Lennon, Alan; Hannah, Victoria E; Ramage, Gordon; Allan, David; Bagg, Jeremy

    2007-01-01

    It has been postulated that bacteria attached to the surface of prosthetic hip joints can cause localised inflammation, resulting in failure of the replacement joint. However, diagnosis of infection is difficult with traditional microbiological culture methods, and evidence exists that highly fastidious or non-cultivable organisms have a role in implant infections. The purpose of this study was to use culture and culture-independent methods to detect the bacteria present on the surface of prosthetic hip joints removed during revision arthroplasties. Ten consecutive revisions were performed by two surgeons, which were all clinically and radiologically loose. Five of the hip replacement revision surgeries were performed because of clinical infections and five because of aseptic loosening. Preoperative and perioperative specimens were obtained from each patient and subjected to routine microbiological culture. The prostheses removed from each patient were subjected to mild ultrasonication to dislodge adherent bacteria, followed by aerobic and anaerobic microbiological culture. Bacterial DNA was extracted from each sonicate and the 16S rRNA gene was amplified with the universal primer pair 27f/1387r. All 10 specimens were positive for the presence of bacteria by both culture and PCR. PCR products were then cloned, organised into groups by RFLP analysis and one clone from each group was sequenced. Bacteria were identified by comparison of the 16S rRNA gene sequences obtained with those deposited in public access sequence databases. A total of 512 clones were analysed by RFLP analysis, of which 118 were sequenced. Culture methods identified species from the genera Leifsonia (54.3%), Staphylococcus (21.7%), Proteus (8.7%), Brevundimonas (6.5%), Salibacillus (4.3%), Methylobacterium (2.2%) and Zimmermannella (2.2%). Molecular detection methods identified a more diverse microflora. The predominant genus detected was Lysobacter, representing 312 (60.9%) of 512 clones

  6. The Impact of Lumbar Spine Disease and Deformity on Total Hip Arthroplasty Outcomes.

    Science.gov (United States)

    Blizzard, Daniel J; Sheets, Charles Z; Seyler, Thorsten M; Penrose, Colin T; Klement, Mitchell R; Gallizzi, Michael A; Brown, Christopher R

    2017-05-01

    Concomitant spine and hip disease in patients undergoing total hip arthroplasty (THA) presents a management challenge. Degenerative lumbar spine conditions are known to decrease lumbar lordosis and limit lumbar flexion and extension, leading to altered pelvic mechanics and increased demand for hip motion. In this study, the effect of lumbar spine disease on complications after primary THA was assessed. The Medicare database was searched from 2005 to 2012 using International Classification of Diseases, Ninth Revision, procedure codes for primary THA and diagnosis codes for preoperative diagnoses of lumbosacral spondylosis, lumbar disk herniation, acquired spondylolisthesis, and degenerative disk disease. The control group consisted of all patients without a lumbar spine diagnosis who underwent THA. The risk ratios for prosthetic hip dislocation, revision THA, periprosthetic fracture, and infection were significantly higher for all 4 lumbar diseases at all time points relative to controls. The average complication risk ratios at 90 days were 1.59 for lumbosacral spondylosis, 1.62 for disk herniation, 1.65 for spondylolisthesis, and 1.53 for degenerative disk disease. The average complication risk ratios at 2 years were 1.66 for lumbosacral spondylosis, 1.73 for disk herniation, 1.65 for spondylolisthesis, and 1.59 for degenerative disk disease. Prosthetic hip dislocation was the most common complication at 2 years in all 4 spinal disease cohorts, with risk ratios ranging from 1.76 to 2.00. This study shows a significant increase in the risk of complications following THA in patients with lumbar spine disease. [Orthopedics. 2017; 40(3):e520-e525.]. Copyright 2017, SLACK Incorporated.

  7. Readmissions after fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik; Otte, Kristian Stahl; Kristensen, Billy B

    2010-01-01

    With the implementation of fast-track surgery with optimization of both logistical and clinical features, the postoperative convalescence has been reduced as functional milestones have been achieved earlier and consequently length of stay (LOS) in hospital has been reduced. However, it has been s...... speculated that a decrease in LOS may be associated with an increase in readmissions in general, including risk of dislocation after total hip arthroplasty (THA) or manipulation after total knee arthroplasty (TKA)....

  8. [Modern tribology in total hip arthroplasty: pros and cons].

    Science.gov (United States)

    Gómez-García, F

    2014-01-01

    The wear products and adverse reactions that occur on bearing surfaces represent one of the greatest challenges in prosthetic replacements, as the latter experience increasing demands due to the large number of young and older adult patients that have a long life expectancy and remarkable activity. The purpose of this review is to analyze the pros and cons of the new advances in the bearing components of the articular surfaces of current total hip arthroplasties. We also discuss the strategies used historically, their problems, results and the surgeon's role in prescribing the tribologic couple that best fits each patient's needs. We conclude with practical recommendations for the prescription and management of the latest articular couples for total hip arthroplasty.

  9. Resection arthroplasty of the hip in paralytic dislocations.

    Science.gov (United States)

    Kalen, V; Gamble, J G

    1984-06-01

    The chronically dislocated paralytic hip causes postural difficulties, nursing and hygiene problems, and pain. Therapeutic options are limited. This study reviews the results of resection arthroplasty on 18 hips of 15 such patients. This procedure has many complications, including hip ankylosis, heterotopic ossification, abduction contracture and bony overgrowth. Despite this, all of the nursing goals were achieved and most patients had relief of pain. The operation is most successful in the skeletally mature patients, and it relies on soft-tissue interposition between the bony fragments and postoperative positioning to ensure optimum posture.

  10. Clinical and Economic Burden of Revision Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    Mohit Bhandari

    2012-01-01

    Full Text Available Surgery is indicated for symptomatic knee osteoarthritis (OA when conservative measures are unsuccessful. High tibial osteotomy (HTO, unicompartmental knee arthroplasty (UKA, and total knee arthroplasty (TKA are surgical options intended to relieve knee OA pain and dysfunction. The choice of surgical intervention is dependent on several factors such as disease location, patient age, comorbidities, and activity levels. Regardless of surgical treatment, complications such as infection, loosening or lysis, periprosthetic fracture, and postoperative pain are known risks and are indications for revision surgery. The clinical and economic implications for revision surgery are underappreciated. Over 55,000 revision surgeries were performed in 2010 in the US, with 48% of these revisions in patients under 65 years. Total costs associated with each revision TKA surgery have been estimated to be in excess of $49,000. The current annual economic burden of revision knee OA surgery is $2.7 billion for hospital charges alone. By 2030, assuming a 5-fold increase in the number of revision procedures, this economic burden will exceed $13 billion annually. It is appealing to envision a therapy that could delay or obviate the need for arthroplasty. From an actuarial standpoint, this would have the theoretical downstream effect of substantially reducing the number of revision procedures. Although no known therapies currently meet these criteria, such a breakthrough would have a tremendous impact in lessening the clinical and economic burden of knee OA revision surgery.

  11. The 22-Modifier in Reimbursement for Orthopedic Procedures: Hip Arthroplasty and Obesity Are Worth the Effort.

    Science.gov (United States)

    Smith, Eric L; Tybor, David J; Daniell, Hayley D; Naccarato, Laura A; Pevear, Mary E; Cassidy, Charles

    2018-02-21

    Orthopedic surgeons utilize the 22-modifier when billing for complex procedures under the American Medical Association's Current Procedural Terminology (CPT) for reasons such as excessive blood loss, anatomic abnormality, and morbid obesity, cases that would ideally be reimbursed at a higher rate to compensate for additional physician work and time. We investigated how the 22-modifier affects physician reimbursement in knee and hip arthroplasty. We queried hospital billing data from 2009 to 2016, identifying all cases performed at our urban tertiary care orthopedic center for knee arthroplasty (CPT codes 27438, 27447, 27487, and 27488) and hip arthroplasty (CPT codes 27130, 27132, 27134, 27236). We extracted patient insurance status and reimbursement data to compare the average reimbursement between cases with and without the 22-modifier. We analyzed data from 2605 procedures performed by 10 providers. There were 136 cases with 22-modifiers. For knee arthroplasty (n = 1323), the 22-modifier did not significantly increase reimbursement after adjusting for insurer, provider, and fiscal year (4.2% dollars higher on average, P = .159). For hip arthroplasty (n = 1282), cases with a 22-modifier had significantly higher reimbursement than those without the 22-modifier (6.2% dollars more, P = .049). For hip arthroplasty cases with a 22-modifier, those noting morbid obesity were reimbursed 29% higher than those cases with other etiology. The effect of the 22-modifier on reimbursement amount is differential between knee and hip arthroplasty. Hip arthroplasty procedures coded as 22-modifier are reimbursed more than those without the 22-modifier. Providers should consider these potential returns when considering submitting a 22-modifier. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Analgesic efficacy of local infiltration analgesia in hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Andersen, Lasse Østergaard; Kehlet, H

    2014-01-01

    In recent years, there has been an increasing interest in local infiltration analgesia (LIA) as a technique to control postoperative pain. We conducted a systematic review of randomized clinical trials investigating LIA for total knee arthroplasty (TKA) and total hip arthroplasty (THA) to evaluate...

  13. Role of patient characteristics for fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Jørgensen, C.; Jacobsen, M; Søballe, Kjeld

    2013-01-01

    BACKGROUND: /st>Patient age and comorbidity have been found to increase the length of hospital stay (LOS), readmissions, and mortality after surgery, including in elective primary total hip arthroplasty (THA) and total knee arthroplasty (TKA). Whether the same applies in fast-track THA and TKA...

  14. Outcomes of dual mobility components in total hip arthroplasty: a systematic review of the literature.

    Science.gov (United States)

    Darrith, B; Courtney, P M; Della Valle, C J

    2018-01-01

    Instability remains a challenging problem in both primary and revision total hip arthroplasty (THA). Dual mobility components confer increased stability, but there are concerns about the unique complications associated with these designs, as well as the long-term survivorship. We performed a systematic review of all English language articles dealing with dual mobility THAs published between 2007 and 2016 in the MEDLINE and Embase electronic databases. A total of 54 articles met inclusion criteria for the final analysis of primary and revision dual mobility THAs and dual mobility THAs used in the treatment of fractures of the femoral neck. We analysed the survivorship and rates of aseptic loosening and of intraprosthetic and extra-articular dislocation. For the 10 783 primary dual mobility THAs, the incidence of aseptic loosening was 1.3% (142 hips); the rate of intraprosthetic dislocation was 1.1% (122 hips) and the incidence of extra-articular dislocation was 0.46% (41 hips). The overall survivorship of the acetabular component and the dual mobility components was 98.0%, with all-cause revision as the endpoint at a mean follow-up of 8.5 years (2 to 16.5). For the 3008 revision dual mobility THAs, the rate of aseptic acetabular loosening was 1.4% (29 hips); the rate of intraprosthetic dislocation was 0.3% (eight hips) and the rate of extra-articular dislocation was 2.2% (67 hips). The survivorship of the acatabular and dual mobility components was 96.6% at a mean of 5.4 years (2 to 8). For the 554 dual mobility THAs which were undertaken in patients with a fracture of the femoral neck, the rate of intraprosthetic dislocation was 0.18% (one hip), the rate of extra-articular dislocation was 2.3% (13 hips) and there was one aseptic loosening. The survivorship was 97.8% at a mean of 1.3 years (0.75 to 2). Dual mobility articulations are a viable alternative to traditional bearing surfaces, with low rates of instability and good overall survivorship in primary and

  15. TWO-STAGE REVISION HIP REPLACEMENT PATIENS WITH SEVERE ACETABULUM DEFECT (CASE REPORT

    Directory of Open Access Journals (Sweden)

    V. V. Pavlov

    2017-01-01

    Full Text Available Favorable short-term results of arthroplasty are observed in 80–90% of cases, however, over the longer follow up period the percentage of positive outcomes is gradually reduced. Need for revision of the prosthesis or it’s components increases in proportion to time elapsed from the surgery. In addition, such revision is accompanied with a need to substitute the bone defect of the acetabulum. As a solution the authors propose to replace pelvic defects in two stages. During the first stage the defect was filled with bone allograft with platelet-rich fibrin (allografting with the use of PRF technology. After the allograft remodeling during the second stage the revision surgery is performed by implanting standard prostheses. The authors present a clinical case of a female patient with aseptic loosening of acetabular component of prosthesis in the right hip joint, with failed hip function of stage 2, right limb shortening of 2 cm. Treatment results confirm the efficiency and rationality of the proposed bone grafting option. The authors conclude bone allograft in combination with the PRF technology proves to be an alternative to the implantation of massive metal implants in the acetabulum while it reduces the risk of implant-associated infection, of metallosis in surrounding tissues and expands further revision options.

  16. Managing uncertainty - a qualitative study of surgeons' decision-making for one-stage and two-stage revision surgery for prosthetic hip joint infection.

    Science.gov (United States)

    Moore, Andrew J; Blom, Ashley W; Whitehouse, Michael R; Gooberman-Hill, Rachael

    2017-04-12

    Approximately 88,000 primary hip replacements are performed in England and Wales each year. Around 1% go on to develop deep prosthetic joint infection. Between one-stage and two-stage revision arthroplasty best treatment options remain unclear. Our aims were to characterise consultant orthopaedic surgeons' decisions about performing either one-stage or two-stage revision surgery for patients with deep prosthetic infection (PJI) after hip arthroplasty, and to identify whether a randomised trial comparing one-stage with two-stage revision would be feasible. Semi-structured interviews were conducted with 12 consultant surgeons who perform revision surgery for PJI after hip arthroplasty at 5 high-volume National Health Service (NHS) orthopaedic departments in England and Wales. Surgeons were interviewed before the development of a multicentre randomised controlled trial. Data were analysed using a thematic approach. There is no single standardised surgical intervention for the treatment of PJI. Surgeons balance multiple factors when choosing a surgical strategy which include multiple patient-related factors, their own knowledge and expertise, available infrastructure and the infecting organism. Surgeons questioned whether it was appropriate that the two-stage revision remained the best treatment, and some surgeons' willingness to consider more one-stage revisions had increased over recent years and were influenced by growing evidence showing equivalence between surgical techniques, and local observations of successful one-stage revisions. Custom-made articulating spacers was a practice that enabled uncertainty to be managed in the absence of definitive evidence about the superiority of one surgical technique over the other. Surgeons highlighted the need for research evidence to inform practice and thought that a randomised trial to compare treatments was needed. Most surgeons thought that patients who they treated would be eligible for trial participation in instances

  17. Older patients can accurately recall their preoperative health status six weeks following total hip arthroplasty.

    Science.gov (United States)

    Marsh, Jackie; Bryant, Dianne; MacDonald, Steven J

    2009-12-01

    In clinical trials, use of patient recall data would be beneficial when the collection of baseline data is impossible, such as in trauma situations. We investigated the ability of older patients to accurately recall their preoperative quality of life, function, and general health status at six weeks following total hip arthroplasty. We randomized consecutive patients who were fifty-five years of age or older into two groups. At each assessment, patients completed self-report questionnaires (at four weeks preoperatively, on the day of surgery, and at six weeks and three months postoperatively for Group 1 and at six weeks and three months postoperatively for Group 2). At six weeks postoperatively, all patients completed the questionnaires on the basis of their recollection of their preoperative health status. We evaluated the validity and reliability of recall ratings, the degree of error in recall ratings, and the effects of the use of recall data on power and sample size requirements. A total of 174 patients (mean age, seventy-one years) who were undergoing either primary or revision total hip arthroplasty were randomized and included in the analysis (118 patients were in Group 1 and fifty-six were in Group 2). Agreement between actual and recalled data was excellent for disease-specific questionnaires (intraclass correlation coefficient, 0.86, 0.87, and 0.88) and moderate for generic health measures (intraclass correlation coefficient, 0.48, 0.58, and 0.60). Increased error associated with recalled ratings compared with actual ratings necessitates minimal increases in sample size or results in small decreases in power. Patients undergoing total hip arthroplasty can accurately recall their preoperative health status at six weeks postoperatively.

  18. Total Hip Arthroplasty in Mucopolysaccharidosis Type IH

    Directory of Open Access Journals (Sweden)

    S. O'hEireamhoin

    2011-01-01

    Full Text Available Children affected by mucopolysaccharidosis (MPS type IH (Hurler Syndrome, an autosomal recessive metabolic disorder, are known to experience a range of musculoskeletal manifestations including spinal abnormalities, hand abnormalities, generalised joint stiffness, genu valgum, and hip dysplasia and avascular necrosis. Enzyme therapy, in the form of bone marrow transplantation, significantly increases life expectancy but does not prevent the development of the associated musculoskeletal disorders. We present the case of a 23-year-old woman with a diagnosis of Hurler syndrome with a satisfactory result following uncemented total hip arthroplasty.

  19. Psychological factors as risk factors for poor hip function after total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Benditz A

    2017-02-01

    Full Text Available Achim Benditz,1 Petra Jansen,2 Jan Schaible,1 Christina Roll,1 Joachim Grifka,1 Jürgen Götz1 1Department of Orthopedics, University Medical Center Regensburg, Asklepios Klinikum Bad Abbach, Bad Abbach, 2Department of Sport Science, University of Regensburg, Regensburg, Germany Abstract: Recovery after total hip arthroplasty (THA is influenced by several psychological aspects, such as depression, anxiety, resilience, and personality traits. We hypothesized that preoperative depression impedes early functional outcome after THA (primary outcome measure. Additional objectives were perioperative changes in the psychological status and their influence on perioperative outcome. This observational study analyzed depression, anxiety, resilience, and personality traits in 50 patients after primary unilateral THA. Hip functionality was measured by means of the Harris Hip Score. Depression, state anxiety, and resilience were evaluated preoperatively as well as 1 and 5 weeks postoperatively. Trait anxiety and personality traits were measured once preoperatively. Patients with low depression and anxiety levels had significantly better outcomes with respect to early hip functionality. Resilience and personality traits did not relate to hip functionality. Depression and state anxiety levels significantly decreased within the 5-week stay in the acute and rehabilitation clinic, whereas resilience remained at the same level. Our study suggests that low depression and anxiety levels are positively related to early functionality after THA. Therefore, perioperative measurements of these factors seem to be useful to provide the best support for patients with risk factors. Keywords: total hip arthroplasty, psychological factors, depression, state anxiety, trait anxiety, resilience, personality traits

  20. Hip arthroplasty. Part 1: prosthesis terminology and classification

    International Nuclear Information System (INIS)

    Pluot, E.; Davis, E.T.; Revell, M.; Davies, A.M.; James, S.L.J.

    2009-01-01

    Hip arthroplasty is an extremely common orthopaedic procedure and there is a wide array of implants that are in current use in the UK. The follow-up of patients who have undergone insertion of a hip prosthesis is shifting from a consultant-lead hospital service towards primary care. As this change in patient care continues it becomes increasingly important that an accurate description of the radiographic features is communicated to the primary-care practitioner so appropriate specialist input can be triggered. This review focuses on the terminology and classification of hip prostheses. This acts as a precursor for Part 2 of this series, which describes the normal and abnormal radiographic findings following hip prosthesis insertion.

  1. Inferior outcome after hip resurfacing arthroplasty than after conventional arthroplasty. Evidence from the Nordic Arthroplasty Register Association (NARA) database, 1995 to 2007

    DEFF Research Database (Denmark)

    Johanson, Per-Erik; Fenstad, Anne Marie; Furnes, Ove

    2010-01-01

    The reported outcomes of hip resurfacing arthroplasty (HRA) vary. The frequency of this procedure in Denmark, Norway, and Sweden is low. We therefore determined the outcome of HRA in the NARA database, which is common to all 3 countries, and compared it to the outcome of conventional total hip...

  2. Bilateral hip arthroplasty: is 1-week staging the optimum strategy?

    Directory of Open Access Journals (Sweden)

    Willis-Owen Charles A

    2010-11-01

    Full Text Available Abstract Seventy-nine patients underwent bilateral hip arthroplasty staged either at 1 week (Group 1 or after greater intervals (as suggested by the patients, mean 44 weeks, range 16-88 weeks (Group 2, over a five year period at one Institution. Sixty-eight patients (29 bilateral hip resurfacings and 39 total hip replacements completed questionnaires regarding their post-operative recovery, complications and overall satisfaction with the staging of their surgery. There was no significant age or ASA grade difference between the patient groups. Complication rates in the two groups were similar and overall satisfaction rates were 84% in Group 1 (n = 32 and 89% in Group 2 (n = 36. Cumulative hospital lengths of stay were significantly longer in Group 1 patients (11.9 days vs 9.1 days(p The mean time to return to part-time work was 16.4 weeks for Group 1, and a cumulative 17.2 weeks (8.8 and 8.4 weeks for Group 2. The time to return to full-time work was significantly shorter for Group 1 patients (21.0 weeks, compared with a cumulative 29.7 weeks for Group 2(p Hip resurfacing patients in Group 2 had significantly shorter durations of postoperative pain and were able to return to part-time and full time work sooner than total hip arthroplasty patients. There was a general trend towards a faster recovery and resumption of normal activities following the second operation in Group 2 patients, compared with the first operation. Bilateral hip arthroplasty staged at a 1-week interval resulted in an earlier resolution of hip pain, and an earlier return to full-time work (particularly following total hip replacement surgery, with high levels of patient satisfaction and no increased risk in complications; however the hospital length of stay was significantly longer. The decision for the timing of staged bilateral surgery should be made in conjunction with the patient, making adjustments to accommodate their occupational needs and functional demands.

  3. POSTERIOR APPROACH FOR HIP ARTHROPLASTY: A SINGLE ...

    African Journals Online (AJOL)

    postulated advantages and disadvantages. Objective: Presentation of a case series of primary and revision arthroplasty utilizing the posterior approach. ... Centre over a period of one year were queried and data extracted and recorded.

  4. Maximum surgical blood ordering schedules for revision lower limb arthroplasty.

    Science.gov (United States)

    Mahadevan, Devendra; Challand, Christopher; Clarke, Andrew; Keenan, Jonathan

    2011-05-01

    Effective utilisation of blood products is fundamental. The introduction of maximum surgical blood ordering schedules (MSBOS) for operations has been shown to improve transfusion services. A retrospective analysis was undertaken to establish an evidence-based MSBOS for revision total hip replacement (THR) and total knee revision (TKR). The impact of this schedule on blood conservation was analysed. A retrospective analysis was undertaken on 397 patients who underwent revision THR and TKR over a 4-year period. The cross-match-to-transfusion ratio (CTR) and transfusion index (TI) were calculated. A MSBOS protocol was created based on the TIs and its' impact on transfusion services was assessed prospectively on 125 patients by comparing CTRs. In revision THR, TI was 1.19 for elective cases, 1.55 for emergency cases and 2.35 for infected cases. There was no difference in TI for revisions of cemented and uncemented components. Single component THR revision required less transfusion. In revision TKR, TI was 0.31 for elective cases, 2.0 for emergency cases and 1.23 for cases with infection. The introduction of the MSBOS protocol had resulted in a considerable improvement in blood ordering. Reductions in the CTR were seen for all types of revision surgery, but most evident in elective revision THR (3.24-2.18) and elective revision TKR (7.95-1.2). Analysis confirmed that excessive cross-matching occurred for revision lower limb arthroplasty. The introduction of our MSBOS protocol promoted blood conservation and compliance with established national guidelines.

  5. Cirrhosis patients have increased risk of complications after hip or knee arthroplasty

    DEFF Research Database (Denmark)

    Deleuran, Thomas; Vilstrup, Hendrik; Overgaard, Søren

    2015-01-01

    Background and purpose: The risk of complications in cirrhosis patients after orthopedic surgery is unclear. We examined this risk after total hip arthroplasty (THA) or total knee arthroplasty (TKA). Patients and methods: Using Danish healthcare registries, we identified all Danish residents who...

  6. Modular femoral component for conversion of previous hip surgery in total hip arthroplasty.

    Science.gov (United States)

    Goldstein, Wayne M; Branson, Jill J

    2005-09-01

    The conversion of previous hip surgery to total hip arthroplasty creates a durable construct that is anatomically accurate. Most femoral components with either cemented or cementless design have a fixed tapered proximal shape. The proximal femoral anatomy is changed due to previous hip surgery for fixation of an intertrochanteric hip fracture, proximal femoral osteotomy, or a fibular allograft for avascular necrosis. The modular S-ROM (DePuy Orthopaedics Inc., Warsaw, Ind) hip stem accommodates these issues and independently prepares the proximal and distal portion of the femur. In preparation and implantation, the S-ROM hip stem creates less hoop stresses on potentially fragile stress risers from screws and thin bone. The S-ROM hip stem also prepares a previously distorted anatomy by milling through cortical bone that can occlude the femoral medullar canals and recreate proper femoral anteversion and reduces the risk of intraoperative or postoperative periprosthetic fracture due to the flexible titanium-slotted stem. The S-ROM femoral stem is recommended for challenging total hip reconstructions.

  7. Novel cemented cup-holding technique while performing total hip arthroplasty with navigation system

    OpenAIRE

    Hirokazu Takai, MD; Tomoki Takahashi, MD, PhD

    2017-01-01

    Recently, navigation systems have been more widely utilized in total hip arthroplasty. However, almost all of these systems have been developed for cementless cups. In the case of cemented total hip arthroplasty using a navigation system, a special-ordered cemented holder is needed. We propose a novel cemented cup-holding technique for navigation systems using readily available articles. We combine a cementless cup holder with an inverted cementless trial cup. The resulting apparatus is used ...

  8. Revision total knee arthroplasty with the use of trabecular metal cones

    DEFF Research Database (Denmark)

    Jensen, Claus L; Petersen, Michael Mygind; Schrøder, Henrik

    2012-01-01

    "Trabecular Metal Cone" (TM Cone) (Zimmer, Inc, Warsaw, Ind) for reconstruction of bone loss in the proximal tibia during revision total knee arthroplasty is now optional. Forty patients were randomized to receive revision total knee arthroplasty with or without TM Cone (No TM Cone). The Anderson...

  9. Hip Fractures and the Bundle: A Cost Analysis of Patients Undergoing Hip Arthroplasty for Femoral Neck Fracture vs Degenerative Joint Disease.

    Science.gov (United States)

    Grace, Trevor R; Patterson, Joseph T; Tangtiphaiboontana, Jennifer; Krogue, Justin D; Vail, Thomas P; Ward, Derek T

    2018-06-01

    The purpose of this study is to determine whether episode Target Prices in the Bundled Payment for Care Improvement (BPCI) initiative sufficiently match the complexities and expenses expected for patients undergoing hip arthroplasty for femoral neck fracture (FNF) as compared to hip degenerative joint disease (DJD). Claims data under BPCI Model 2 were collected for patients undergoing hip arthroplasty at a single institution over a 2-year period. Payments from the index hospitalization to 90 days postoperatively were aggregated by Medicare Severity Diagnosis-Related Group (469 or 470), indication (DJD vs FNF), and categorized as index procedure, postacute services, and related hospital readmissions. Actual episode costs and Target Prices were compared in both the FNF and DJD cohorts undergoing hip arthroplasty to gauge the cost discrepancy in each group. A total of 183 patients were analyzed (31 with FNFs, 152 with DJD). In total, the FNF cohort incurred a $415,950 loss under the current episode Target Prices, whereas the DJD cohort incurred a $172,448 gain. Episode Target Prices were significantly higher than actual episode prices for the DJD cohort ($32,573 vs $24,776, P expenses incurred by FNF patients undergoing hip arthroplasty. Better risk-adjusting Target Prices for this fragile population should be considered to avoid disincentives and delays in care. Copyright © 2018 Elsevier Inc. All rights reserved.

  10. [The method and result analyses of pathogenic bacteria culture on chronic periprosthetic joint infection after total knee arthroplasty and total hip arthroplasty].

    Science.gov (United States)

    Ji, Baochao; Xu, Enjie; Cao, Li; Yang, Desheng; Xu, Boyong; Guo, Wentao; Aili, Rehei

    2015-02-01

    To analyze the results of pathogenic bacteria culture on chronic periprosthetic joint infection after total knee arthroplasty (TKA) and total hip arthroplasty (THA). The medical data of 23 patients with chronic periprosthetic joint infection after TKA or THA from September 2010 to March 2014 were reviewed. Fifteen cases of TKA and 8 cases of THA were included in this study. There were 12 male and 11 female patients with the mean age of 62 years (range from 32 to 79 years), and among them 9 patients with sinus. All patients discontinued antibiotic therapy for a minimum of 2 weeks before arthrocentesis, taking pathogenic bacteria culture and antimicrobial susceptibility test by using synovial fluid taken preoperatively and intraoperatively of revision. Common pathogenic bacteria culture and pathological biopsy were taken on tissues intraoperatively of revision. Culture-negative specimens were prolonged the period of incubation for 2 weeks. The overall culture-positive rate of all 23 patients for 1 week before revision was 30.4% (7/23), and the positive rate of culture-negative samples which prolonged for 2 weeks was 39.1% (9/23). The overall culture-positive rate of patients for 1 week intraoperatively of revision was 60.9% (14/23), and the positive rate of culture-negative samples which prolonged for 2 weeks was 82.6% (19/23). The incubation results of 7 cases (30.4%) preoperatively conformed to that of intraoperation. The culture-positive rate of pathogenic bacteria culture can be increased evidently by discontinuing antimicrobial therapy for a minimum of 2 weeks prior to the definite diagnosis.

  11. Gait symmetry and hip strength in women with developmental dysplasia following hip arthroplasty compared to healthy subjects : A cross-sectional study

    NARCIS (Netherlands)

    Leijendekkers, Ruud A.; Marra, Marco A.; Kolk, Sjoerd; Van Bon, Geert; Schreurs, B. Wim; Weerdesteyn, Vivian; Verdonschot, Nico

    2018-01-01

    Introduction: Untreated unilateral developmental dysplasia of the hip (DDH) results in asymmetry of gait and hip strength and may lead to early osteoarthritis, which is commonly treated with a total hip arthroplasty (THA). There is limited knowledge about the obtained symmetry of gait and hip

  12. Bone remodelling of the proximal femur after total hip arthroplasty with 2 different hip implant designs

    DEFF Research Database (Denmark)

    Christiansen, Janus D.; Laursen, Mogens B; Ejaz, Ashir

    2018-01-01

    INTRODUCTION: The thrust plate prosthesis (TPP) was introduced to preserve bone in patients undergoing total hip arthroplasty. We assessed the long-term results of hip arthroplasty in patients who received the TPP compared to a traditional intramedullary stem (Bi-Metric). METHODS......: In this prospective observational cohort study, we evaluated bone mineral density (BMD) using dual-energy X-ray absorptiometry (DXA), radiological imaging and clinical outcome using Harris Hip Score (HHS). Twenty patients received the TPP (group A) and 18 patients received the Bi-Metric stem (group B). Baseline......% (95% confidence interval [CI], 4-16; p = 0.003) and 8% (95% CI, 1-15; p = 0.03) at 8 years. Regarding ROI4, group A had a lesser decrease in general compared to group B. The radiological findings did not reveal any subsidence or detectable implant migration. HHS improved from 53 (23-69) to 93 (55...

  13. An Insight into Methods and Practices in Hip Arthroplasty in Patients with Rheumatoid Arthritis

    Directory of Open Access Journals (Sweden)

    Mohammad Saeed Mosleh-shirazi

    2015-01-01

    Full Text Available Total hip arthroplasty (THA has improved the quality of life of patients with hip arthritis. Orthopedic community is striving for excellence to improve surgical techniques and postoperative care. Despite these efforts, patients continue facing postoperative complications. In particular, patients with rheumatoid arthritis display a higher risk of certain complications such as dislocation, periprosthetic infection, and shorter prosthesis durability. In this review we present the current knowledge of hip arthroplasty in patients with rheumatoid arthritis with more insight into common practices and interventions directed at enhancing recovery of these patients and current shortfalls.

  14. Assessment and management of chronic pain in patients with stable total hip arthroplasty

    OpenAIRE

    Classen, Tim; Zaps, Daniela; Landgraeber, Stefan; Li, Xinning; Jäger, Marcus

    2012-01-01

    Total hip arthroplasty (THA) is one of the most successful operations that can restore function and relieve pain. Although a majority of the patients achieve significant pain relief after THA, there are a number of patients that develop chronic pain for unknown reasons. A literature search was performed looking for chronic pain after total hip arthroplasty and stable THA. Major causes of chronic pain include aseptic loosening or infection. However, there is a subset of patients with a stable ...

  15. Low risk of thromboembolic complications after fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik; Otte, Niels Kristian Stahl; Kristensen, Billy B

    2010-01-01

    Pharmacological prophylaxis can reduce the risk of deep venous thrombosis (DVT), pulmonary embolism (PE), and death, and it is recommended 10–35 days after total hip arthroplasty (THA) and at least 10 days after total knee arthroplasty (TKA). However, early mobilization might also reduce the risk...

  16. Total Hip Arthroplasty Using a Polished Tapered Cemented Stem in Hereditary Multiple Exostosis

    Science.gov (United States)

    Kanda, Akio; Kaneko, Kazuo; Obayashi, Osamu; Mogami, Atsuhiko

    2016-01-01

    A 61-year-old Japanese man underwent right total hip arthroplasty for hereditary multiple exostosis. At first presentation, he had suffered from coxalgia for a long time. On radiographic images, there was a gigantic femoral head, increased shaft angle, and large diameter of the femoral neck. He had also developed coxarthrosis and severe pain of the hip joint. The transformation of the proximal femur bone causes difficulty in setting a cementless total hip prosthesis. Therefore, total hip arthroplasty using a cemented polished tapered stem was performed via a direct lateral approach. Using a cemented polished tapered stem allowed us to deal with the femoral bone transformation and bone substance defectiveness due to exostosis and also minimized the invasiveness of the operation. PMID:27127668

  17. Total hip arthroplasty and perioperative oral carbohydrate treatment: a randomised, double-blind, controlled trial.

    Science.gov (United States)

    Harsten, Andreas; Hjartarson, Hjörtur; Toksvig-Larsen, Sören

    2012-06-01

    Perioperative oral carbohydrate intake is beneficial to general surgery patients. Total hip arthroplasty is a common surgical procedure, and even a moderate improvement in patient outcome could have a significant effect on the resources needed for these patients. However, few studies have focused on the effects of carbohydrate intake on orthopaedic patients. The purpose of this study was to investigate if perioperative oral carbohydrate intake alters the postoperative course for patients undergoing total hip arthroplasty. The primary hypothesis was that pain scores would be lower in patients treated with carbohydrate. A randomised, double-blind, controlled trial. This study was carried out between September 2009 and April 2011 at a district Swedish hospital that specialises in orthopaedic surgery. Sixty ASA physical status I-III patients scheduled for elective total hip arthroplasty were included. Exclusion criteria were obesity, diabetes, prior hip surgery to the same hip, ongoing infection, immunological deficiency or age less than 50 or more than 80 years. Patients were given 400 ml of either an oral 12.5% carbohydrate solution or a placebo beverage (flavoured water) 1.5 h before and 2 h after surgery. Visual analogue scales were used to score six discomfort parameters. Immediately prior to surgery, the carbohydrate-treated patients were less hungry (median score 9.5 vs. 22 mm) and experienced less nausea (0 vs. 1.5 mm) (Phip arthroplasty.

  18. [Quality in Revision Arthroplasty: A Comparison between Claims Data Analysis and External Quality Assurance].

    Science.gov (United States)

    Wessling, M; Gravius, S; Gebert, C; Smektala, R; Günster, C; Hardes, J; Rhomberg, I; Koller, D

    2016-02-01

    External quality assurance for revisions of total knee arthroplasty (TKA) and total hip arthroplasty (THA) are carried out through the AQUA institute in Germany. Data are collected by the providers and are analyzed based on predefined quality indicators from the hospital stay in which the revision was performed. The present study explores the possibility to add routine data analysis to the existing external quality assurance (EQS). Differences between methods are displayed. The study aims to quantify the benefit of an additional analysis that allows patients to be followed up beyond the hospitalization itself. All persons insured in an AOK sickness fund formed the population for analysis. Revisions were identified using the same algorithm as the existing external quality assurance. Adverse events were defined according to the AQUA indicators for the years 2008 to 2011.The hospital stay in which the revision took place and a follow-up of 30 days were included. For re-operation and dislocation we also defined a 365 days interval for additional follow-up. The results were compared to the external quality control reports. Almost all indicators showed higher events in claims data analysis than in external quality control. Major differences are seen for dislocation (EQS SD: 1.87 vs. claims data [cd] SD: 2.06 %, cd+30 d: 2.91 %, cd+365 d: 7.27 %) and reoperation (hip revision: EQS SD: 5.88 % vs. claims data SD: 8.79 % cd+30 d: 9.82 %, cd+365 d: 15.0 %/knee revision: EQS SD: 3.21 % vs. claims data SD: 4.07 %, cd+30 d: 4.6 %, cd+365 d: 15.43 %). Claims data could show additional adverse events for all indicators after the initial hospital stay, rising to 77 % of all events. The number of adverse events differs between the existing external quality control and our claims data analysis. Claims data give the opportunity to complement existing methods of quality control though a longer follow-up, when many complications become evident. Georg

  19. Long-term Outcome of Unconstrained Primary Total Hip Arthroplasty in Ipsilateral Residual Poliomyelitis.

    Science.gov (United States)

    Buttaro, Martín A; Slullitel, Pablo A; García Mansilla, Agustín M; Carlucci, Sofía; Comba, Fernando M; Zanotti, Gerardo; Piccaluga, Francisco

    2017-03-01

    Incapacitating articular sequelae in the hip joint have been described for patients with late effects of poliomyelitis. In these patients, total hip arthroplasty (THA) has been associated with a substantial rate of dislocation. This study was conducted to evaluate the long-term clinical and radiologic outcomes of unconstrained THA in this specific group of patients. The study included 6 patients with ipsilateral polio who underwent primary THA between 1985 and 2006. Patients with polio who underwent THA on the nonparalytic limb were excluded. Mean follow-up was 119.5 months (minimum, 84 months). Clinical outcomes were evaluated with the modified Harris Hip Score (mHHS) and the visual analog scale (VAS) pain score. Radiographs were examined to identify the cause of complications and determine the need for revision surgery. All patients showed significantly better functional results when preoperative and postoperative mHHS (67.58 vs 87.33, respectively; P=.002) and VAS pain score (7.66 vs 2, respectively; P=.0003) were compared. Although 2 cases of instability were diagnosed, only 1 patient needed acetabular revision as a result of component malpositioning. None of the patients had component loosening, osteolysis, or infection. Unconstrained THA in the affected limb of patients with poliomyelitis showed favorable long-term clinical results, with improved function and pain relief. Nevertheless, instability may be a more frequent complication in this group of patients compared with the general population. [Orthopedics. 2017; 40(2):e255-e261.]. Copyright 2016, SLACK Incorporated.

  20. Surgery-induced changes and early recovery of hip-muscle strength, leg-press power, and functional performance after fast-track total hip arthroplasty

    DEFF Research Database (Denmark)

    Holm, Bente; Thorborg, Kristian; Husted, Henrik

    2013-01-01

    By measuring very early changes in muscle strength and functional performance after fast-track total hip arthroplasty (THA), post-operative rehabilitation, introduced soon after surgery, can be designed to specifically target identified deficits.......By measuring very early changes in muscle strength and functional performance after fast-track total hip arthroplasty (THA), post-operative rehabilitation, introduced soon after surgery, can be designed to specifically target identified deficits....

  1. Manual calf massage and passive ankle motion reduce the incidence of deep vein thromboembolism after total hip arthroplasty.

    Science.gov (United States)

    Imai, Norio; Ito, Tomoyuki; Suda, Ken; Miyasaka, Dai; Endo, Naoto

    2017-07-01

    Venous thromboembolism is one of the general complications following total hip arthroplasty, wherein various preventive treatments have been recommended. Several studies reported that venous thromboembolism incidence after total hip arthroplasty was similar in patients who were administered prophylaxis with a conventional mechanical procedure alone, and those who were administered pharmacological anticoagulation therapy. Therefore, the optimum methods of prophylaxis are still controversial. The purpose of this study was to investigate whether manual calf massage and passive ankle motion could lower the risk for venous thromboembolism after total hip arthroplasty. We retrospectively reviewed the data of 126 consecutive patients undergoing elective primary unilateral total hip arthroplasty wherein manual calf massage and passive ankle motion were performed after the surgery at our hospitals between January and October 2014. The 138 patients of the control group underwent total hip arthroplasty using the same surgical approach and pre- and postoperative protocols without this mechanical prophylaxis between January and December 2013. This mechanical prophylaxis was performed simultaneously 30 times during approximately 10 s; these procedures were repeated thrice immediately after total hip arthroplasty. Duplex ultrasonography was performed to observe the veins of both legs in all the patients on postoperative day 7. The incidence of deep vein thrombosis was 6.52% and 0.79% in the control and manual calf massage and passive ankle motion groups, respectively. The odds ratio for the manual calf massage and passive ankle motion groups was 8.72. Performing this mechanical prophylaxis reduced the incidence of venous thromboembolism after total hip arthroplasty. This mechanical prophylaxis is not only simple and easy, but is also safe and inexpensive. We therefore recommend that manual calf massage and passive ankle motion be performed in patients who will undergo total hip

  2. Patient Satisfaction Reporting After Total Hip Arthroplasty: A Systematic Review.

    Science.gov (United States)

    Kahlenberg, Cynthia A; Nwachukwu, Benedict U; Schairer, William W; Steinhaus, Michael E; Cross, Michael B

    2017-05-01

    This review evaluated the quality of patient satisfaction reporting after total hip arthroplasty. The initial search of the MEDLINE database yielded 755 studies. Twenty-four met the inclusion criteria. Most studies provided level III or IV evidence (n=15, 62.5%). The most common method used to assess satisfaction was the 10-point visual analog scale (7 studies, 29.2%), followed by an ordinal satisfaction scale (6 studies, 25.0%). The quality of evidence was poor, and the methods used to assess satisfaction were not standardized. Further research is needed to define the factors that affect patient satisfaction after total hip arthroplasty and how satisfaction is best measured. [Orthopedics. 2017; 40(3):e400-e404.]. Copyright 2017, SLACK Incorporated.

  3. Dual mobility cups for preventing early hip arthroplasty dislocation in patients at risk: experience in a county hospital

    Directory of Open Access Journals (Sweden)

    Sebastian S. Mukka

    2013-06-01

    Full Text Available Dislocation remains a major concern after hip arthroplasty. We asked whether dual mobility cups (DMC would improve early hip stability in patients with high risk of dislocation. We followed 34 patients (21 females, 13 males treated between 2009 and 2012 with cemented DMC for hip revisions caused recurrent hip prosthetic dislocation or as a primary procedure in patients with high risk of instability. Functional outcome and quality of life were evaluated using Harris Hip Score and EQ-5D respectively. We found that the cemented DMC gave stability in 94%. Seven patients (20% were re-operated due to infection. One patient sustained a periprosthetic fracture. At follow-up (6 to 36 months, mean 18, the mean Harris hip score was 67 (standard deviation: 14 and mean EQ-5D was 0.76 (standard deviation: 0.12. We concluded that treating patients with high risk of dislocation with DMC can give good stability. However, complications such as postoperative infection can be frequent and should be managed carefully.

  4. The association between metal allergy, total knee arthroplasty, and revision

    DEFF Research Database (Denmark)

    Münch, Henrik J; Jakobsen, Stig Storgaard; Olesen, Jens T

    2015-01-01

    BACKGROUND AND PURPOSE: It is unclear whether delayed-type hypersensitivity reactions against implanted metals play a role in the etiopathogenesis of malfunctioning total knee arthroplasties. We therefore evaluated the association between metal allergy, defined as a positive patch test reaction...... to common metal allergens, and revision surgery in patients who underwent knee arthroplasty. PATIENTS AND METHODS: The nationwide Danish Knee Arthroplasty Register, including all knee-implanted patients and revisions in Denmark after 1997 (n = 46,407), was crosslinked with a contact allergy patch test......, the prevalence of cobalt and chromium allergy was markedly higher. Metal allergy that was diagnosed before implant surgery appeared not to increase the risk of implant failure and revision surgery. INTERPRETATION: While we could not confirm that a positive patch test reaction to common metals is associated...

  5. Alumina-on-Polyethylene Bearing Surfaces in Total Hip Arthroplasty

    OpenAIRE

    Jung, Yup Lee; Kim, Shin-Yoon

    2010-01-01

    The long-term durability of polyethylene lining total hip arthroplasty (THA) mainly depends on periprosthetic osteolysis due to wear particles, especially in young active patients. In hip simulator study, reports revealed significant wear reduction of the alumina ceramic-on-polyethylene articulation of THA compared with metal-on-polyethylene bearing surfaces. However, medium to long-term clinical studies of THA using the alumina ceramic-on-polyethylene are few and the reported wear rate of th...

  6. THE INFLUENCE OF THE SURGICAL APPROACH CONCERNING DISLOCATION IN TOTAL HIP ARTHROPLASTY.

    Science.gov (United States)

    Vicente, José Ricardo Negreiros; Pires, André Fernandes; Lee, Bruno Takasaki; Leonhardt, Marcos Camargo; Ejnisman, Leandro; Croci, Alberto Tesconi

    2009-01-01

    Our primary aim was to evaluate the occurrence of dislocation of non-cemented total hip arthroplasty, when using the posterior and the direct lateral approaches. We performed a comparative retrospective study with 232 patients submitted to non-cemented total hip arthroplasty, due to the diagnosis of primary or secondary osteoarthritis. The posterior approach was used in 105 patients while direct lateral approach was used in 127 patients. There was only one prosthesis model and the same rehabilitation program and post-operative care was used for all patients. We checked the occurrence of dislocation, the acetabular positioning and also the size of the components. There was only one case of dislocation, treated with closed reduction successfully. This was a 47 year-old female, submitted to direct lateral approach. The mean follow-up time for both groups was 23.7 months, ranging from six to 42 months. The authors conclude that the prevalence of total hip arthroplasty dislocation is similar for both approaches, and educational measures besides the use of a higher femoral offset seem to reduce the risk of this complication.

  7. Prospective psychometric characterization of hip and knee arthroplasty patients

    DEFF Research Database (Denmark)

    Gylvin, Silas Hinsch; Fink-Jensen, Anders; Kehlet, Henrik

    2018-01-01

    BACKGROUND: Psychiatric conditions and psychopharmacological treatments have been demonstrated to be important risk-factors for prolonged hospital length of stay, readmission and morbidity, following fast-track total hip (THA) and total knee arthroplasty (TKA). AIMS: The aim of the study...

  8. Imaging of hip joint arthroplasty; Bildgebung bei Hueftgelenkendoprothesen

    Energy Technology Data Exchange (ETDEWEB)

    Mayerhoefer, M.E.; Fruehwald-Pallamar, J.; Czerny, C. [Univ.-Klinik fuer Radiodiagnostik, Medizinische Universitaet Wien, Abteilung fuer Neuroradiologie und Muskuloskelettale Radiologie, Wien (Austria)

    2009-05-15

    The hip joint is the largest joint in the human body and consequently, its evaluation by diagnostic imaging is highly important. This includes imaging of hip joint arthroplasty, which is used to avoid joint immobility following a wide spectrum of diseases, such as end-stage degenerative disease, avascular necrosis of the femoral head or post-traumatic fractures. Conventional radiography is still the standard imaging modality for the evaluation of hip arthroplasty both directly following surgery and for periodical follow-up. In the majority of cases conventional radiography enables adequate assessment of early and late complications that can arise following hip arthroplasty, such as loosening, prosthetic or periprosthetic fracture, luxation, infection and soft tissue calcification. If the diagnosis cannot be established by means of radiography, advanced imaging methods such as computed tomography (CT) and magnetic resonance imaging (MRI), with or without injection of contrast media, may provide additional information. This is particularly true for the depiction of inflammatory processes. Regardless of the imaging modality used patients' clinical symptoms must also be taken into account in order to establish the correct diagnosis. (orig.) [German] Dem Hueftgelenk als groesstem Gelenk des menschlichen Koerpers kommt eine besondere Bedeutung in der muskuloskelettalen Radiologie zu. Entsprechend wichtig ist auch die radiologische Beurteilung von Hueftgelenkendoprothesen, die z. B. infolge degenerativer Gelenkerkrankungen, einer Hueftkopfnekrose oder einer Fraktur eingesetzt werden. Die Projektionsradiographie ist weiterhin die primaere Modalitaet zur Beurteilung von Hueftgelenkendoprothesen, direkt postoperativ und zur laengerfristigen Verlaufskontrolle. Diese Methode erlaubt in der Mehrzahl der Faelle eine suffiziente Antwort auf die Frage nach Lockerung, periprothetischer Fraktur oder Prothesenmaterialbruch, Luxation, Infektion und Weichteilkalzifikation

  9. Delirium after fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Krenk, Lene; Rasmussen, L S; Hansen, T B

    2012-01-01

    hospital stay and medical morbidity. No data on PD are available in fast-track surgery. The aim of this study was to evaluate the incidence of PD after fast-track hip (THA) and knee arthroplasty (TKA) with anticipated length of stay (LOS) of In a prospective multicentre study to evaluate postoperative...

  10. Increased risk of revision for infection in rheumatoid arthritis patients with total hip replacements

    DEFF Research Database (Denmark)

    Schrama, Johannes Cornelis; Fenstad, Anne M; Dale, Håvard

    2015-01-01

    Background and purpose-Medical treatment of rheumatoid arthritis (RA) has changed dramatically over the last 15 years, including immune modulation. We investigated the risk of revision for infection after primary total hip replacement (THR) in patients with rheumatoid arthritis over a 16-year...... period, and compared it with that in THR patients with osteoarthritis (OA).Patients and methods-We identified 13,384 THRs in RA patients and 377,287 THRs in OA patients from 1995 through 2010 in a dataset from the Nordic Arthroplasty Register Association (NARA). Kaplan-Meier survival curves......, with revision for infection as the endpoint, were constructed. Cox regression analyses were performed to calculate the relative risk (RR) of revision for infection adjusted for age, sex, fixation technique, and year of primary surgery.Results-RA patients had a 1.3 times (95% CI 1.0-1.6) higher risk of revision...

  11. Type 2 diabetes and in-hospital complications after revision of total hip and knee arthroplasty.

    Directory of Open Access Journals (Sweden)

    Ana López-de-Andrés

    Full Text Available To assess the effect of type 2 diabetes (T2DM on hospital outcomes such as in hospital postoperative complications (IHPC, length of hospital stay (LOHS and in-hospital mortality (IHM after the revision of total hip arthroplasty (RHA and total knee arthroplasty (RKA and to identify factors associated with IHPC among T2DM patients undergoing these procedures.We performed a retrospective study using the Spanish National Hospital Discharge Database, 2005-2014. We included patients who were ≥40 years old that had undergone RHA and RKA. For each T2DM patient, we selected a year-, gender-, age- and Charlson Comorbidity Index-matched non-diabetic patient.We identified 44,055 and 39,938 patients who underwent RHA (12.72% with T2DM and RKA (15.01% with T2DM. We matched 4,700 and 5,394 couples with RHA and RKA, respectively. Any IHPC was more frequent among patients with T2DM than among non-T2DM patients (19% vs. 15.64% in the RHA cohort and 12.94% vs. 11.09% in the RKA cohort, respectively. For patients who underwent RHA, postoperative infection (4.51% vs. 2.94%, p<0.001, acute post-hemorrhagic anemia (9.53% vs. 7.70%, p<0.001, mean LOHS and IHM were significantly higher in patients with T2DM. Among RKA patients, the incidence of acute posthemorrhagic anemia (7.21% vs. 5.62%; p = 0.001 and urinary tract infection (1.13% vs. 0.72%; p = 0.029 was significantly higher in patients with diabetes. Older age, obesity, infection due to internal joint prosthesis, myocardial infarction, congestive heart failure, mild liver disease and renal disease and emergency room admission were significantly associated with a higher risk of IHPC in T2DM patients. IHPC decreased over time only in T2DM patients who underwent RHA (OR 0.94, 95%CI 0.89-0.98.Patients with T2DM who underwent RHA and RKA procedures had more IHPC after controlling for the effects of possible confounders. LOHS and IHM were also higher among RHA patients with diabetes. Older age, comorbidity, obesity

  12. Patient-reported outcome of hip resurfacing arthroplasty and standard total hip replacement after short-term follow-up

    DEFF Research Database (Denmark)

    Nissen, Nina; Douw, Karla; Overgaard, Søren

    2011-01-01

    The purpose of this study was to investigate patientreported outcome in terms of satisfaction in two study groups that had undergone hip resurfacing arthro-plasty (HRA) or total hip replacement (THR). The procedure consists of placing a hollow, mushroom-shaped metal cap over the femoral head whil...... a matching metal cup is placed in the acetabulum (pelvis socket)....

  13. The “true” incidence of surgically treated deep prosthetic joint infection after 32,896 primary total hip arthroplasties

    Science.gov (United States)

    Gundtoft, Per Hviid; Overgaard, Søren; Schønheyder, Henrik Carl; Møller, Jens Kjølseth; Kjærsgaard-Andersen, Per; Pedersen, Alma Becic

    2015-01-01

    Background and purpose It has been suggested that the risk of prosthetic joint infection (PJI) in patients with total hip arthroplasty (THA) may be underestimated if based only on arthroplasty registry data. We therefore wanted to estimate the “true” incidence of PJI in THA using several data sources. Patients and methods We searched the Danish Hip Arthroplasty Register (DHR) for primary THAs performed between 2005 and 2011. Using the DHR and the Danish National Register of Patients (NRP), we identified first revisions for any reason and those that were due to PJI. PJIs were also identified using an algorithm incorporating data from microbiological, prescription, and clinical biochemistry databases and clinical findings from the medical records. We calculated cumulative incidence with 95% confidence interval. Results 32,896 primary THAs were identified. Of these, 1,546 had first-time revisions reported to the DHR and/or the NRP. For the DHR only, the 1- and 5-year cumulative incidences of PJI were 0.51% (0.44–0.59) and 0.64% (0.51–0.79). For the NRP only, the 1- and 5-year cumulative incidences of PJI were 0.48% (0.41–0.56) and 0.57% (0.45–0.71). The corresponding 1- and 5-year cumulative incidences estimated with the algorithm were 0.86% (0.77–0.97) and 1.03% (0.87–1.22). The incidences of PJI based on the DHR and the NRP were consistently 40% lower than those estimated using the algorithm covering several data sources. Interpretation Using several available data sources, the “true” incidence of PJI following primary THA was estimated to be approximately 40% higher than previously reported by national registries alone. PMID:25637247

  14. Pain and somatosensory findings in patients 3 years after total hip arthroplasty

    DEFF Research Database (Denmark)

    Nikolajsen, Lone; Kristensen, Anders D; Thillemann, Theis M

    2009-01-01

    in patients and controls. Patients with chronic hip pain had higher scores on the mental vulnerability scale (Poperated side, which was more prominent in patients...... with chronic hip pain and 18 controls without chronic hip pain were recruited from a previous questionnaire study about hip pain after total hip arthroplasty. All participants answered questions about pain and mental vulnerability and underwent clinical examination followed by quantitative sensory testing...... with pain. Pain referred from the back or deeper structures in the hip seems to play a role for the pain in subgroups of patients. In addition, chronic hip pain was associated with mental vulnerability....

  15. International metal-on-metal multidisciplinary teams: do we manage patients with metal-on-metal hip arthroplasty in the same way? An analysis from the International Specialist Centre Collaboration on MOM Hips (ISCCoMH).

    Science.gov (United States)

    Berber, R; Skinner, J; Board, T; Kendoff, D; Eskelinen, A; Kwon, Y-M; Padgett, D E; Hart, A

    2016-02-01

    There are many guidelines that help direct the management of patients with metal-on-metal (MOM) hip arthroplasties. We have undertaken a study to compare the management of patients with MOM hip arthroplasties in different countries. Six international tertiary referral orthopaedic centres were invited to participate by organising a multi-disciplinary team (MDT) meeting, consisting of two or more revision hip arthroplasty surgeons and a musculoskeletal radiologist. A full clinical dataset including history, blood tests and imaging for ten patients was sent to each unit, for discussion and treatment planning. Differences in the interpretation of findings, management decisions and rationale for decisions were compared using quantitative and qualitative methods. Overall agreement between the orthopaedic centres and the recommended treatment plans for the ten patients with MOM hip implants was moderate (kappa = 0.6). Full agreement was seen in a third of cases, however split decisions were also seen in a third of cases. Units differed in their interpretation of the significance of the investigation findings and put varying emphasis on serial changes, in the presence of symptoms. In conclusion, the management of raised or rising blood metal ions, cystic pseudotumours and peri-acetabular osteolysis led to inconsistency in the agreement between centres. Coordinated international guidance and MDT panel discussions are recommended to improve consensus in decision making. A lack of evidence and the subsequent variation in regulator guidance leads to differences in opinions, the clinical impact of which can be reduced through a multi-disciplinary team approach to managing patients with MOM hip implants. Cite this article: Bone Joint J 2016;98-B:179-86. ©2016 The British Editorial Society of Bone & Joint Surgery.

  16. Long-term result of cementless femoral stem in avascular necrosis of the hip.

    Science.gov (United States)

    Cheung, Kin W; Chiu, Kwok H; Chung, Kwong Y

    2015-01-01

    Avascular necrosis (AVN) of the hip may have extensive involvement of the proximal femur which may affect boney ingrowth into cementless femoral stems. From 1994 to 2004, 182 total hip arthroplasties (in 144 patients, 117 AVN hips and 65 non-AVN hips) were performed using hydroxyapatite coated femoral stems. All patients were followed up prospectively. Mean age was 51 years and mean follow-up 14.7 years (range 9.7-19.1 years). Four stems were revised because of aseptic loosening, 3 in AVN group and 1 in non-AVN group. The overall mechanical failure rate was 2.2%, the mechanical failure rate in AVN and non-AVN group was 2.6% and 1.5% respectively (p = 1). The 19.1 year survival using revision for aseptic loosening as an endpoint for AVN and non-AVN patients were 97.1% and 96.2% respectively (p = 0.654). Stable boney ingrowth was present in 99.5% hips. This study represents 1 of the largest series reporting the long-term follow-up of the use of cementless femoral stems in treating AVN of the hip. We report excellent long-term survival of cementless total hip arthroplasty used in managing AVN of the hip and is comparable to that seen in non-AVN total hip arthroplasty.

  17. The Consumer Quality Index Hip Knee Questionnaire measuring patients' experience with quality of care after a total hip or knee arthroplasty.

    NARCIS (Netherlands)

    Stubbe, J.H.; Gelsema, T.; Delnoij, D.M.J.

    2007-01-01

    Background: The Dutch Consumer Quality Index Hip Knee Questionnaire (CQI Hip Knee) was used to assess patients' experiences with and evaluations of quality of care after a total hip (THA) or total knee arthroplasty (TKA). The aim of this study is to evaluate the construct validity and internal

  18. Comparison of radiographic and radionuclide hip arthrography in determination of femoral component loosening of hip arthroplasties

    International Nuclear Information System (INIS)

    Capello, W.N.; Uri, B.G.; Wellman, H.N.; Robb, J.A.; Stiver, P.L.

    1985-01-01

    Radiographic examination of a patient experiencing pain following total hip arthroplasty is an important step in the systematic approach to evaluating component loosening, even though the information yielded is often equivocal and nondiagnostic in assessing component loosening. The radiographic criteria for loosening are especially difficult to assess following revision surgery, for radiolucent lines frequently exist at the bone-cement interface immediately following implantation. The advent of noncemented hip prostheses poses another problem: the routinely noted disruption of bone-cement of prosthesis-cement interfaces is not present with uncemented prostheses. As the criteria for loosening of the noncemented prostheses are still evolving, plain radiographic examination is frequently nondiagnostic. Femoral component loosening is difficult to detect with standard contrast arthrography because the bone, metal, surrounding radiopaque cement and contrast agents have similar or identical radiographic appearances. In contrast arthrography, if the prosthesis is loose the injected agent opacifies the radiolucent zone encircling the prosthesis or cement mangle. Because of the similarity in the appearances of these agents and the surrounding structures on x-ray films, interpretation is difficult. The inclusion of subtraction techniques in routine contrast arthrography has improved its accuracy; however, these techniques require special equipment and demand precise patient positioning. The purpose of this study is to introduce a new form of hip arthrography using a radionuclide agent in place of the contrast agent. A comparison of the results using these two techniques is presented

  19. [Sport activity after hip and knee arthroplasty].

    Science.gov (United States)

    Keren, Amit; Berkovich, Yaron; Berkovitch, Yaron; Soudry, Michael

    2013-11-01

    Joint arthroplasty is one of the commonest surgical procedures in orthopedic surgery. In recent years there was an increase in the number of procedures, patient satisfaction and implant survival. Originally, these operations were designed for old patients in order to relieve pain and to enable ambulation. Over the past few years, these operations have become common in younger patients which desire to return to activity, including sports activities. The importance of physical activity is a well known fact. In recent years it became clear that with the proper physical activity the outcomes of the operations are better. There are several types of arthroplasty. Many factors influence the outcome of the operation apart from the post-surgery physical activity. These factors include patient factors, surgical technique and type of arthroplasty. This review summarizes the recommendations for sports activities after hip and knee arthroplasties. These activities are evaluated according to surgeons' recommendations, stress applied on the implant and long term outcomes. The recommended sports activities after joint arthroplasties are walking, swimming and cycling. Soccer, basketball and jogging are not advised. Tennis, downhill skiing and horse riding are recommended with previous experience. There are many more sports activities that patients can participate in, and it is important that the patient discuss the different options prior to the operation. Since these operations are so common, many non-orthopedic physicians encounter these patients in their practice. They should be acquainted with the recommendations for sports activities and encourage them.

  20. Knitted outer gloves in primary hip and knee arthroplasty.

    Science.gov (United States)

    Tanner, J; Wraighte, P; Howard, P

    2006-01-01

    A randomised trial was carried out to determine the rate of perforation to inner gloves when comparing latex with knitted gloves during hip and knee arthroplasty. Members of the surgical team were randomised to wear either two pairs of latex gloves (standard double gloving) or a knitted glove on top of a latex glove. In addition, participants completed a visual analogue assessment of their overall satisfaction with the gloves. A total of 406 inner gloves were tested for perforations over a four-month period: 23% of inner gloves were perforated when latex outer gloves were used and 6% of inner gloves were perforated when knitted outer gloves were used. In total, there were 64 perforations to the inner gloves; only one of these perforations was detected by the glove wearer. Wearing knitted outer gloves during hip and knee arthroplasty statistically significantly reduces the risk of perforation to inner latex gloves (p<0.0001).

  1. Treatment of primary hip osteoarthritis for the primary care physician and the indications for total hip arthroplasty.

    Science.gov (United States)

    Levine, Mathew E; Nace, James; Kapadia, Bhaveen H; Issa, Kimona; Banerjee, Samik; Cherian, Jeffery J; Mont, Michael A

    2013-01-01

    Osteoarthritis is a degenerative condition that commonly affects knees and hips with an annual incidence of 88 in 100,000 people in the United States. The purpose of this study was to review the clinical presentation of osteoarthritis of the hip as well as the available management options. We reviewed the recent literature in regard to epidemiology, presentation, and treatment options available to patients. Nonoperative treatments include weight loss and low-impact, aerobic exercises. Along with weight loss and exercise, nonsteroidal anti-inflammatory drugs (NSAIDS), narcotics, and intra-articular steroid injections have been used to improve patient's symptoms. Surgical intervention is a viable option; however, indications such as severe pain that is refractory to nonsurgical management, osteophytes, or joint space narrowing on radiographic films, or impairment of function should be present. The most common surgical option, total hip arthroplasty, has been shown to improve a patient's physical and psychological well-being. However, inherent risks are present with surgery and these should be addressed with the patient so a sound decision can be made. Osteoarthritis of the hip can be bothersome to patients, but physicians can begin management with lifestyle changes or pharmaceuticals. In the event nonoperative measures fail to markedly improve quality of life, total hip arthroplasty remains a viable option.

  2. The history of biomechanics in total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Jan Van Houcke

    2017-01-01

    Full Text Available Biomechanics of the hip joint describes how the complex combination of osseous, ligamentous, and muscular structures transfers the weight of the body from the axial skeleton into the appendicular skeleton of the lower limbs. Throughout history, several biomechanical studies based on theoretical mathematics, in vitro, in vivo as well as in silico models have been successfully performed. The insights gained from these studies have improved our understanding of the development of mechanical hip pathologies such as osteoarthritis, hip fractures, and developmental dysplasia of the hip. The main treatment of end-stage degeneration of the hip is total hip arthroplasty (THA. The increasing number of patients undergoing this surgical procedure, as well as their demand for more than just pain relief and leading an active lifestyle, has challenged surgeons and implant manufacturers to deliver higher function as well as longevity with the prosthesis. The science of biomechanics has played and will continue to play a crucial and integral role in achieving these goals. The aim of this article, therefore, is to present to the readers the key concepts in biomechanics of the hip and their application to THA.

  3. Evaluation of shelf arthroplasty as a treatment for hip dysplasia in dogs.

    Science.gov (United States)

    Oakes, M G; Lewis, D D; Elkins, A D; Hosgood, G; Dial, S M; Oliver, J

    1996-06-01

    To evaluate effects of shelf arthroplasty on coxofemoral joint laxity and progression of degenerative joint disease in young dogs with hip dysplasia. Prospective, controlled study. 10 dogs between 10 and 24 months old and weighing between 20 and 27 kg. All dogs had bilateral coxofemoral joint laxity (i.e., an Ortolani's sign). In all dogs, shelf arthroplasty was performed on the right coxofemoral joints, and a sham procedure was performed on the left. Dogs were evaluated before and after surgery by means of lameness assessment, coxofemoral joint palpation and goniometry, thigh circumference measurement, and radiography. There were no significant changes in coxofemoral joint mobility, range of motion, joint laxity, degree of degenerative joint disease, or thigh circumference during the study. A greater amount of periacetabular bone formed on the right side than on the left side; however, dogs did not develop large bony shelves, and the amount of periarticular bone decreased over time. The polymer implants remained in their original position and were encapsulated by fibrous tissue. There was no histologic evidence of osteoconduction by the implants. The polymer implants used in this procedure do not appear to be osteoconductive. Shelf arthroplasty was associated with minimal morbidity and was not associated with serious adverse sequelae in this study, but the procedure did not alter the progression of hip dysplasia in these dogs. We cannot advocate shelf arthroplasty using this polymer as a treatment for dogs with hip dysplasia.

  4. COXA-VERTEBRAL SYNDROME AND ITS SIGNIFICANCE IN HIP ARTHROPLASTY (REVIEW

    Directory of Open Access Journals (Sweden)

    A. O. Denisov

    2012-01-01

    Full Text Available Lumbosacral spine and hip joints is a complex physiological functions of the co-operation of a large number of anatomical structures. Lesions of the links in the system can mutually afflict each other. Combined pathology of the hip and lumbosacral spine is called hip-spine syndrome, or coxa-vertebral syndrome. Symptoms of the joint and spine are very similar and only a careful examination and clinical examination may find the differences. As the disease progresses the hip increases the restriction of movement, there is a contracture of the limbs in a vicious position, which leads to an increase in tilt of the pelvis, increased lumbar lordosis and to functional shortening of limbs on the affected side. This gives rise to functional impairment, and then strain the joints of his spine and disease - osteochondrosis and scoliosis. After the successful operation of total hip replacement is often progressive clinical lesions of vertebral segment, which is manifested pain and is often offset by the results of arthroplasty as the restoration of movement in the hip joint, and the change in length limb after arthroplasty leads to rupture formed a functional stereotype change in the mobility of the lumbar spine, pelvis regression bias that causes the dynamic compression spinal nerve root. Depending on the duration of the existence, severity and nature of changes in the pelvic girdle is suitable correction of equipment replacement surgery, including, for example, in some cases, deliberate shortening or lengthening the preservation of the lower extremity, offset change, etc.

  5. Difference in clinical outcome between total shoulder arthroplasty and reverse shoulder arthroplasty used in hemiarthroplasty revision surgery

    NARCIS (Netherlands)

    Hartel, B.P.; Alta, T.D.; Sewnath, M.E.; Willems, W.J.H.

    2015-01-01

    INTRODUCTION: The increase of shoulder replacements will lead to a higher revision rate of shoulder arthroplasties. The aim of this study is to evaluate the clinical results of revision surgery performed in our hospital, distinguish the differences in clinical outcome according to revision

  6. A randomised, controlled clinical study on total hip arthroplasty using 4 different bearings

    DEFF Research Database (Denmark)

    Borgwardt, Arne; Zerahn, Bo; Fabricius, Sandra D

    2017-01-01

    PURPOSE: To compare 4 different bearings in total hip arthroplasty (THA) in a randomised controlled clinical study on clinical performance. METHODS: 393 patients with osteoarthritis of the hip or avascular necrosis were included and allocated to 1 of the head-and-cup couples zirconia...

  7. Effect of body mass index on functional outcomes following arthroplasty procedures.

    Science.gov (United States)

    Polat, Gokhan; Ceylan, Hasan Huseyin; Sayar, Safak; Kucukdurmaz, Fatih; Erdil, Mehmet; Tuncay, Ibrahim

    2015-12-18

    To evaluate the body mass index (BMI) change in arthroplasty patients and its impact on the patients' functional results. Between October 2010 and May 2013, 606 patients who were operated due to gonarthrosis, coxarthrosis, aseptic loosening of the total knee and hip prosthesis were evaluated prospectively. Patients were operated by three surgeons in three medical centers. Patients who were between 30-90 years of age and who were underwent total knee arthroplasty, total hip arthroplasty, revision knee arthroplasty, or revision hip arthroplasty were included in the study. We excluded the patients who cannot tolerate our standard postoperative rehabilitation program. Additionally, patients who had systemic inflammatory diseases, diabetes mellitus, or endochrinopathies were excluded from the study. The remaining 513 patients comprised our study group. Preoperative functional joint scores, height, weight and BMI of all patients were recorded. We used the Knee Society Score (KSS) for knee and Harris Hip Score (HHS) for hip patients. Postoperative functional scores were measured at 1(st), 6(th) and 12(th) months and recorded separately at outpatient visits. The mean age of the patients was 64.7 (range: 30-90) years (207 males/306 females) and the mean follow-up duration was 14.3 (range: 12-26) mo. We found that arthroplasty patients had weight gain and had an increase in BMI at the postoperative 1(st), 6(th) and 12(th) months. The mean BMI of the patients was 27.7 preoperatively, 27.8 at the postoperative 1(st) month, 28.1 at the 6(th) month and 28.6 at the 12(th) month (P < 0.01). At the last visit, the mean postoperative HHS of the hip arthroplasty patients was 82.2 ± 7.12 (preoperatively, 52.3; 1(st) month, 78.2; 6(th) month, 81.1; 12(th) month, 82.2), and the mean KSS of the knee arthroplasty patients was 79.3 ± 4.31 (preoperatively, 35.8; 1(st) month, 75.2; 6(th) month, 79.1; 12(th) month, 79.3). Worse functional results were noted in the patients who had a BMI

  8. Thigh and knee circumference, knee-extension strength, and functional performance after fast-track total hip arthroplasty

    DEFF Research Database (Denmark)

    Holm, Bente; Kristensen, Morten Tange; Husted, Henrik

    2011-01-01

    OBJECTIVE: To (1) quantify changes in knee-extension strength and functional-performance at discharge after fast-track total hip arthroplasty (THA) and (2) investigate whether these changes correlate to changes in thigh and knee circumference (ie, swelling) or pain. DESIGN: A prospective, descrip......OBJECTIVE: To (1) quantify changes in knee-extension strength and functional-performance at discharge after fast-track total hip arthroplasty (THA) and (2) investigate whether these changes correlate to changes in thigh and knee circumference (ie, swelling) or pain. DESIGN: A prospective......, descriptive, hypothesis-generating study. SETTING: A special unit for fast-track hip and knee arthroplasty operations at a university hospital. PARTICIPANTS: Twenty-four patients (20 women and 4 men; ages 69 ± 6.1 years) scheduled for primary unilateral THA. METHODS: All patients were evaluated before surgery......, except for hip pain. The average loss in knee-extension strength after surgery (32%, P = .01) did not correlate with increased thigh circumference (6%, P

  9. Endotoxins in surgical instruments of hip arthroplasty

    OpenAIRE

    Goveia, Vania Regina; Mendoza, Isabel Yovana Quispe; Guimarães, Gilberto Lima; Ercole, Flavia Falci; Couto, Bráulio Roberto Gonçalves Marinho; Leite, Edna Marilea Meireles; Stoianoff, Maria Aparecida Resende; Ferreira, José Antonio Guimarães

    2016-01-01

    Abstract OBJECTIVE To investigate endotoxins in sterilized surgical instruments used in hip arthroplasties. METHOD A descriptive exploratory study conducted in a public teaching hospital. Six types of surgical instruments were selected, namely: acetabulum rasp, femoral rasp, femoral head remover, chisel box, flexible bone reamer and femoral head test. The selection was based on the analysis of the difficulty in removing bone and blood residues during cleaning. The sample was made up of 60...

  10. AQUILA: assessment of quality in lower limb arthroplasty. An expert Delphi consensus for total knee and total hip arthroplasty.

    Science.gov (United States)

    Pijls, Bart G; Dekkers, Olaf M; Middeldorp, Saskia; Valstar, Edward R; van der Heide, Huub J L; Van der Linden-Van der Zwaag, Henrica M J; Nelissen, Rob G H H

    2011-07-22

    In the light of both the importance and large numbers of case series and cohort studies (observational studies) in orthopaedic literature, it is remarkable that there is currently no validated measurement tool to appraise their quality. A Delphi approach was used to develop a checklist for reporting quality, methodological quality and generalizability of case series and cohorts in total hip and total knee arthroplasty with a focus on aseptic loosening. A web-based Delphi was conducted consisting of two internal rounds and three external rounds in order to achieve expert consensus on items considered relevant for reporting quality, methodological quality and generalizability. The internal rounds were used to construct a master list. The first external round was completed by 44 experts, 35 of them completed the second external round and 33 of them completed the third external round. Consensus was reached on an 8-item reporting quality checklist, a 6-item methodological checklist and a 22-item generalizability checklist. Checklist for reporting quality, methodological quality and generalizability for case series and cohorts in total hip and total knee arthroplasty were successfully created through this Delphi. These checklists should improve the accuracy, completeness and quality of case series and cohorts regarding total hip and total knee arthroplasty.

  11. High bacterial contamination rate of electrocautery tips during total hip and knee arthroplasty.

    Science.gov (United States)

    Abdelaziz, Hussein; Zahar, Akos; Lausmann, Christian; Gehrke, Thorsten; Fickenscher, Helmut; Suero, Eduardo M; Gebauer, Matthias; Citak, Mustafa

    2018-04-01

    The aim of the study was to quantify the bacterial contamination rate of electrocautery tips during primary total joint replacement (TJR), as well as during aseptic and septic revision TJR. A total of 150 electrocautery tips were collected between April and July 2017. TJR surgeries were divided into three groups: (1) primary, (2) aseptic and (3) septic revisions. In each group, a total of 50 electrocautery tips were collected. A monopolar electrocautery with a reusable stainless-steel blade tip was used in all cases. The rate of bacterial contamination was determined for all groups. Correlation of exposure time and type of surgery was analyzed. The overall bacterial contamination rate was 14.7% (95% CI 9.4 to 21.4%). The highest contamination rate occurred in the septic revision group (30.0%; 95% CI 17.9 to 44.6%), followed by the primary cases group (10.0%; 95% CI 3.3 to 21.8%) and the aseptic revision group (4.0%; 95% CI 0.5 to 13.7%). Exposure time did not affect the bacterial contamination rate. In 12 out of 15 (80%) contaminations identified in the septic group, we found the same causative microorganism of the prosthetic joint infection on the electrocautery tip. The bacterial contamination of the electrocautery tips is relatively high, especially during septic hip revision arthroplasty. Electrocautery tips should be changed after debridement of infected tissue.

  12. Survivorship and complications of total hip arthroplasty in patients with dwarfism.

    Science.gov (United States)

    Modi, Ronuk M; Kheir, Michael M; Tan, Timothy L; Penny, Gregory S; Chen, Chi-Lung; Shao, Hongyi; Chen, Antonia F

    2017-09-19

    Total hip arthroplasty (THA) is a common procedure used to treat bony hip deformities and skeletal dysplasia in dwarfism. These surgeries are often more difficult than conventional THA as they may involve malformed joints and poor bone quality, and may require smaller prostheses. This study aims to investigate whether implant survivorship and revision rates vary among patients with and without dwarfism undergoing THA. A retrospective case-control study was performed for 102 THAs completed between 1997 and 2014 in patients under the height threshold of 147.32 cm. This cohort was matched 1:1.5 with patients of normal height with respect to age, gender, year of surgery, and Charlson comorbidities. All cases had a minimum follow-up of 1 year. A chart review was performed to identify patient and surgical characteristics, including outcomes. Radiographs were assessed for deformity, loosening, and periprosthetic fractures among other factors. The 2-, 5-, and 10-year survivorship of THA in patients with dwarfism was 92.9%, 92.9%, and 80.7%, respectively; and 94.4%, 86.4%, and 86.4% for controls, respectively (p = 0.95). The dwarfism cohort demonstrated an OR of 3.81 and 3.02 for revision for periprosthetic fractures (p = 0.11) and mechanical wear (p = 0.21), respectively. THA in patients with dwarfism achieves comparable results to a non-dwarfism population with regards to implant survivorship; however, there is a trend toward increased periprosthetic fractures and wear-related failures. Surgeons should be aware of this potentially higher risk in this population and take morphological differences into account during surgical planning and technique.

  13. Physiotherapy Exercise After Fast-Track Total Hip and Knee Arthroplasty: Time for Reconsideration?

    DEFF Research Database (Denmark)

    Bandholm, Thomas; Kehlet, Henrik

    2012-01-01

    Bandholm T, Kehlet H. Physiotherapy exercise after fast-track total hip and knee arthroplasty: time for reconsideration? Major surgery, including total hip arthroplasty (THA) and total knee arthroplasty (TKA), is followed by a convalescence period, during which the loss of muscle strength......-track methodology or enhanced recovery programs. It is the nature of this methodology to systematically and scientifically optimize all perioperative care components, with the overall goal of enhancing recovery. This is also the case for the care component "physiotherapy exercise" after THA and TKA. The 2 latest...... meta-analyses on the effectiveness of physiotherapy exercise after THA and TKA generally conclude that physiotherapy exercise after THA and TKA either does not work or is not very effective. The reason for this may be that the "pill" of physiotherapy exercise typically offered after THA and TKA does...

  14. Prevention of post-operative anaemia in hip and knee arthroplasty - a systematic review

    DEFF Research Database (Denmark)

    Khan, Nissa; Troelsen, Anders; Husted, Henrik

    2015-01-01

    and length of hospital stay. The papers were evidence-graded. Non-randomised clinical studies and papers not concerning total hip or knee arthroplasty were excluded as were studies lacking a control group. Subanalyses were performed for tran-examic acid, tourniquet and fibrin use. RESULTS: A total of 49...... studies were found eligible which is equivalent to a total of 4,752 patients. Tranexamic acid administered either orally, topically, intravenously or in combination decreased blood loss, increased the post-operative haemoglobin level, decreased the number of patients receiving blood transfusions...... and minimised the length of stay. A similar result was found for fibrin spray in total hip arthroplasty. However, for total knee arthroplasty, the outcome was blurred. Tourniquet use was uniformly not significant in the measured parameters. CONCLUSIONS: Tranexamic acid is useful in managing anaemia and blood...

  15. Experience of the posterior lip augmentation device in a regional hip arthroplasty unit as a treatment for recurrent dislocation.

    Science.gov (United States)

    Hoggett, L; Cross, C; Helm, T

    2017-12-01

    Dislocation after total hip arthroplasty (THA) remains a significant complication of the procedure and is the third leading cause for revision THA. One technique for treatment of this complication is the use of the posterior lip augmentation device (PLAD). We describe our experience using the PLAD including complication rates. A retrospective review of 55 PLADs (54 patients) was carried out following identification from electronic theatre records. Basic patient demographics, operative records and radiographs were collected and reviewed and data was analysed using Microsoft Excel. Failure of the PLAD was defined as further operative intervention after PLAD insertion and included: dislocation, implant breakage, infection and revision of the THA for loosening of either component. 55 PLADs were implanted in 54 patients with an average age of 77 years. There was a significant preponderance of females and a variety of surgical approaches had been used for the original hip replacement, including trochanteric osteotomy, posterior and antero-lateral. 9 (16%) patients had recurrent dislocations,1 (2%) failed secondary to screw breakage, 3 (5%) had and infection requiring intervention and 2 (4%) underwent further revision for aseptic loosening of the femoral component. The overall failure rate was 25% with 14 patients requiring intervention post PLAD. Our results are inferior to other published results and indicate that the PLAD should be used with caution for recurrent dislocations of the Charnley hip replacement.

  16. Use of Hip Arthroscopy and Risk of Conversion to Total Hip Arthroplasty: A Population-Based Analysis.

    Science.gov (United States)

    Schairer, William W; Nwachukwu, Benedict U; McCormick, Frank; Lyman, Stephen; Mayman, David

    2016-04-01

    To use population-level data to (1) evaluate the conversion rate of total hip arthroplasty (THA) within 2 years of hip arthroscopy and (2) assess the influence of age, arthritis, and obesity on the rate of conversion to THA. We used the State Ambulatory Surgery Databases and State Inpatient Databases for California and Florida from 2005 through 2012, which contain 100% of patient visits. Hip arthroscopy patients were tracked for subsequent primary THA within 2 years. Out-of-state patients and patients with less than 2 years follow-up were excluded. Multivariate analysis identified risks for subsequent hip arthroplasty after arthroscopy. We identified 7,351 patients who underwent hip arthroscopy with 2 years follow-up. The mean age was 43.9 ± 13.7 years, and 58.8% were female patients. Overall, 11.7% of patients underwent THA conversion within 2 years. The conversion rate was lowest in patients aged younger than 40 years (3.0%) and highest in the 60- to 69-year-old group (35.0%) (P arthroscopy. Patients treated at high-volume hip arthroscopy centers had a lower THA conversion rate than those treated at low-volume centers (15.1% v 9.7%, P arthroscopy is performed in patients of various ages, including middle-aged and elderly patients. Older patients have a higher rate of conversion to THA, as do patients with osteoarthritis or obesity. Level III, retrospective comparative study. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  17. Fast track in total hip and knee arthroplasty--experiences from Hvidovre University Hospital, Denmark

    DEFF Research Database (Denmark)

    Husted, Henrik; Holm, Gitte

    2006-01-01

    This study investigated whether unselected patients operated on with total hip arthroplasty (THA) or total knee arthroplasty (TKA) could accomplish a self-developed accelerated track, ANORAK-HH, with a planned length of stay (LOS) of maximum 5 days and patient satisfaction at all parts of the tra...

  18. The effect of endoskeleton on antibiotic impregnated cement spacer for treating deep hip infection

    Directory of Open Access Journals (Sweden)

    Hsu Wei-Hsiu

    2011-01-01

    Full Text Available Abstract Backgrounds A two-stage revision arthroplasty was suggested optimal treatment for deep infections in hip joint. The effect of endoskeleton of cement spacers on the interim function and infection control remains unclear. Methods From Jan. 2004 to Dec. 2007, we collected a prospective cohort of consecutive 34 patients who treated with two-stage revision total hip arthroplasty for deep infection of hip joint. In group 1, fifteen patients were treated by a novel design augmented with hip compression screw while nineteen patients were treated by traditional design in group 2. Results No fracture of cement spacer occurred in group 1 while 6 cases developed spacer failure in group 2. (p Conclusions Patients being treated for deep infection of hip joint using cement spacer augmented with stronger endoskeleton have lower pain levels and better joint function between stages.

  19. Revision Hip Arthroscopy Indications and Outcomes: A Systematic Review.

    Science.gov (United States)

    Sardana, Vandit; Philippon, Marc J; de Sa, Darren; Bedi, Asheesh; Ye, Lily; Simunovic, Nicole; Ayeni, Olufemi R

    2015-10-01

    To identify the indications and outcomes in patients undergoing revision hip arthroscopy. The electronic databases Embase, Medline, HealthStar, and PubMed were searched from 1946 to July 19, 2014. Two blinded reviewers searched, screened, and evaluated the data quality of the studies using the Methodological Index for Non-Randomized Studies scale. Data were abstracted in duplicate. Agreement and descriptive statistics are presented. Six studies were included (3 prospective case series and 3 retrospective chart reviews), with a total of 448 hips examined. The most common indications for revision hip arthroscopy included residual femoroacetabular impingement (FAI), labral tears, and chondral lesions. The mean interval between revision arthroscopy and the index procedure was 25.6 months. Overall, the modified Harris Hip Score improved by a mean of 33.6% (19.3 points) from the baseline score at 1-year follow-up. In 14.6% of patients, further surgical procedures were required, including re-revision hip arthroscopy (8.0%), total hip replacement (5.6%), and hip resurfacing (1.0%). Female patients more commonly underwent revision hip arthroscopy (59.7%). The current evidence examined in this review supports revision hip arthroscopy as a successful intervention to improve functional outcomes (modified Harris Hip Score) and relieve pain in patients with residual symptoms after primary FAI surgery, although the outcomes are inferior when compared with a matched cohort of patients undergoing primary hip arthroscopy for FAI. The main indication for revision is a candidate who has symptoms due to residual cam- or pincer-type deformity that was either unaddressed or under-resected during the index operation. However, it is important to consider that the studies included in this review are of low-quality evidence. Surgeons should consider incorporating a minimum 2-year follow-up for individuals after index hip-preservation surgery because revisions tended to occur within this

  20. Natural Remission of Major Periprosthetic Osteolysis following Total Hip Arthroplasty with Metal-on-Metal Bearings

    Directory of Open Access Journals (Sweden)

    Tatsuya Tamaki

    2017-01-01

    Full Text Available The natural course of adverse events following the use of metal-on-metal (MoM bearings in total hip arthroplasty (THA is not well known. In this article, we report the case of a patient with asymptomatic major acetabular osteolysis following MoM THA that diminished gradually without any surgical intervention. A 58-year-old male underwent one-stage bilateral MoM THA for bilateral osteoarthritis. Four years after THA, major acetabular osteolysis developed in his right hip without any local or systemic symptoms. The patient underwent a careful radiographic and clinical observation without any surgical intervention because he did not want to undergo revision surgery. The lesion gradually diminished after 7 years, and most of the osteolytic area was replaced by newly formed bone at 10 years. He continues to be followed with no evidence of cup loosening or migration. Our observation suggests that a periprosthetic osteolytic change related to the use of MoM bearings has the potential for natural remission.

  1. Cemented total hip replacement cable debris and acetabular construct durability.

    Science.gov (United States)

    Altenburg, Aaron J; Callaghan, John J; Yehyawi, Tameem M; Pedersen, Douglas R; Liu, Steve S; Leinen, Jessica A; Dahl, Kevin A; Goetz, Devon D; Brown, Thomas D; Johnston, Richard C

    2009-07-01

    Third-body wear can adversely affect the outcome of total hip arthroplasty by causing increased polyethylene wear, osteolysis, and component loosening. We hypothesized that there would be greater generation and migration of metal debris to the bearing surfaces in hips in which cobalt-chromium cables were used to reattach the osteotomized greater trochanter when compared with hips in which stainless steel wires were used. Between June 1981 and December 1983, 196 consecutive total hip arthroplasties were performed with use of an Iowa stem and a titanium-backed cemented acetabular component, with cobalt-chromium cable trochanteric reattachment. After nineteen to twenty years of follow-up, the patients were evaluated with regard to the depth of head penetration into the polyethylene (as a surrogate for wear), osteolysis, loosening, and the need for revision. The results were compared with those for a series of 304 total hip arthroplasties that were performed by the same surgeon from January 1984 to December 1985 with use of the same components and the same surgical technique, but with stainless steel wire trochanteric reattachment. The two groups had a comparable nineteen to twenty-year follow-up. All living patients (fifty-nine hips in the cable group and ninety-two hips in the wire group) had minimum ten-year follow-up radiographs. The polyethylene wear rate was 0.101 mm/yr for the cable group and 0.082 mm/yr for the wire group (p = 0.039). For the living patients, the rate of revision of the acetabular component because of aseptic loosening was 37.3% (twenty-two hips) for the cable group and 20.7% (nineteen hips) for the wire group (p = 0.025). The rate of acetabular osteolysis was 44% (twenty-six hips) for the cable group and 26% (twenty-four hips) for the wire group (p = 0.022). Kaplan-Meier analysis with revision of the acetabular component because of aseptic loosening as the end point demonstrated survival rates of 73.7% +/- 9% and 83% +/- 7% for the cable and

  2. The Current State of Screening and Decolonization for the Prevention of Staphylococcus aureus Surgical Site Infection After Total Hip and Knee Arthroplasty.

    Science.gov (United States)

    Weiser, Mitchell C; Moucha, Calin S

    2015-09-02

    The most common pathogens in surgical site infections after total hip and knee arthroplasty are methicillin-sensitive Staphylococcus aureus (MSSA), methicillin-resistant S. aureus (MRSA), and coagulase-negative staphylococci. Patients colonized with MSSA or MRSA have an increased risk for a staphylococcal infection at the site of a total hip or knee arthroplasty. Most colonized individuals who develop a staphylococcal infection at the site of a total hip or total knee arthroplasty have molecularly identical S. aureus isolates in their nares and wounds. Screening and nasal decolonization of S. aureus can potentially reduce the rates of staphylococcal surgical site infection after total hip and total knee arthroplasty. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.

  3. The High Value Healthcare Collaborative: Observational Analyses of Care Episodes for Hip and Knee Arthroplasty Surgery.

    Science.gov (United States)

    Weeks, William B; Schoellkopf, William J; Sorensen, Lyle S; Masica, Andrew L; Nesse, Robert E; Weinstein, James N

    2017-03-01

    Broader use of value-based reimbursement models will require providers to transparently demonstrate health care value. We sought to determine and report cost and quality data for episodes of hip and knee arthroplasty surgery among 13 members of the High Value Healthcare Collaborative (HVHC), a consortium of health care systems interested in improving health care value. We conducted a retrospective, cross-sectional observational cohort study of 30-day episodes of care for hip and knee arthroplasty in fee-for-service Medicare beneficiaries aged 65 or older who had hip or knee osteoarthritis and used 1 of 13 HVHC member systems for uncomplicated primary hip arthroplasty (N = 8853) or knee arthroplasty (N = 16,434), respectively, in 2012 or 2013. At the system level, we calculated: per-capita utilization rates; postoperative complication rates; standardized total, acute, and postacute care Medicare expenditures for 30-day episodes of care; and the modeled impact of reducing episode expenditures or per-capita utilization rates. Adjusted per-capita utilization rates varied across HVHC systems and postacute care reimbursements varied more than 3-fold for both types of arthroplasty in both years. Regression analysis confirmed that total episode and postacute care reimbursements significantly differed across HVHC members after considering patient demographic differences. Potential Medicare cost savings were greatest for knee arthroplasty surgery and when lower total reimbursement targets were achieved. The substantial variation that we found offers opportunities for learning and collaboration to collectively improve outcomes, reduce costs, and enhance value. Ceteris paribus, reducing per-episode reimbursements would achieve greater Medicare cost savings than reducing per-capita rates. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Novel cemented cup-holding technique while performing total hip arthroplasty with navigation system.

    Science.gov (United States)

    Takai, Hirokazu; Takahashi, Tomoki

    2017-09-01

    Recently, navigation systems have been more widely utilized in total hip arthroplasty. However, almost all of these systems have been developed for cementless cups. In the case of cemented total hip arthroplasty using a navigation system, a special-ordered cemented holder is needed. We propose a novel cemented cup-holding technique for navigation systems using readily available articles. We combine a cementless cup holder with an inverted cementless trial cup. The resulting apparatus is used as a cemented cup holder. The upside-down cup-holding technique is useful and permits cemented cup users to utilize a navigation system for placement of the acetabular component.

  5. Novel cemented cup-holding technique while performing total hip arthroplasty with navigation system

    Directory of Open Access Journals (Sweden)

    Hirokazu Takai, MD

    2017-09-01

    Full Text Available Recently, navigation systems have been more widely utilized in total hip arthroplasty. However, almost all of these systems have been developed for cementless cups. In the case of cemented total hip arthroplasty using a navigation system, a special-ordered cemented holder is needed. We propose a novel cemented cup-holding technique for navigation systems using readily available articles. We combine a cementless cup holder with an inverted cementless trial cup. The resulting apparatus is used as a cemented cup holder. The upside-down cup-holding technique is useful and permits cemented cup users to utilize a navigation system for placement of the acetabular component.

  6. Hip malformation is a very common finding in young patients scheduled for total hip arthroplasty

    DEFF Research Database (Denmark)

    Karimi, Dennis; Kallemose, Thomas; Troelsen, Anders

    2018-01-01

    and prevalences of hip malformations were; CAM-deformity 50.9 and 25.5%, coxa profunda 33 and 27.4%, acetabular retroversion 33 and 29.2%, and acetabular dysplasia 10.4 and 3.8%. All patients showed minimum of one malformation. Prevalences of Tönnis grade 0-1 were 22.6% and 2-3 were 77.4%. CONCLUSION: All......INTRODUCTION: In Denmark, 20% of all registered total hip arthroplasties (THA) from 1995 to 2014 has been patients younger than 60 years with primary idiopathic osteoarthritis (OA). It is speculated that hip malformations may be a major contributor to early OA development. It has been shown...... that hip malformation may compromise implant position and, therefore, identifying and knowing the incidence of malformations is important. Our aim was to assess the prevalence and type of hip malformations in a cohort of younger patients undergoing THA. MATERIALS AND METHODS: In this prospective two center...

  7. Alumina-on-Polyethylene Bearing Surfaces in Total Hip Arthroplasty.

    Science.gov (United States)

    Jung, Yup Lee; Kim, Shin-Yoon

    2010-02-11

    The long-term durability of polyethylene lining total hip arthroplasty (THA) mainly depends on periprosthetic osteolysis due to wear particles, especially in young active patients. In hip simulator study, reports revealed significant wear reduction of the alumina ceramic-on-polyethylene articulation of THA compared with metal-on-polyethylene bearing surfaces. However, medium to long-term clinical studies of THA using the alumina ceramic-on-polyethylene are few and the reported wear rate of this articulation is variable. We reviewed the advantages and disadvantages of ceramicon- polyethylene articulation in THA, hip simulator study and retrieval study for polyethylene wear, in vivo clinical results of THA using alumina ceramic-on-polyethylene bearing surfaces in the literature, and new trial alumina ceramic-onhighly cross linked polyethylene bearing surfaces.

  8. Post-Discharge Care Duration, Charges, and Outcomes Among Medicare Patients After Primary Total Hip and Knee Arthroplasty.

    Science.gov (United States)

    Ponnusamy, Karthikeyan E; Naseer, Zan; El Dafrawy, Mostafa H; Okafor, Louis; Alexander, Clayton; Sterling, Robert S; Khanuja, Harpal S; Skolasky, Richard L

    2017-06-07

    In April 2016, the U.S. Centers for Medicare & Medicaid Services initiated mandatory 90-day bundled payments for total hip and knee arthroplasty for much of the country. Our goal was to determine duration of care, 90-day charges, and readmission rates by discharge disposition and U.S. region after hip or knee arthroplasty. Using the 2008 Medicare Provider Analysis and Review database 100% sample, we identified patients who had undergone elective primary total hip or knee arthroplasty. We collected data on patient age, sex, comorbidities, U.S. Census region, discharge disposition, duration of care, 90-day charges, and readmission. Multivariate regression was used to assess factors associated with readmission (logistic) and charges (linear). Significance was set at p total hip arthroplasties were discharged to home (18%), home health care (34%), extended-care facilities (35%), and inpatient rehabilitation (13%); patients undergoing 329,233 total knee arthroplasties were discharged to home (21%), home health care (38%), extended-care facilities (31%), and inpatient rehabilitation (10%). Patients in the Northeast were more likely to be discharged to extended-care facilities or inpatient rehabilitation than patients in other regions. Patients in the West had the highest 90-day charges. Approximately 70% of patients were discharged home from extended-care facilities, whereas after inpatient rehabilitation, >50% of patients received home health care. Among those discharged to home, 90-day readmission rates were highest in the South (9.6%) for patients undergoing total hip arthroplasty and in the Midwest (8.7%) and the South (8.5%) for patients undergoing total knee arthroplasty. Having ≥4 comorbidities, followed by discharge to inpatient rehabilitation or an extended-care facility, had the strongest associations with readmission, whereas the region of the West and the discharge disposition to inpatient rehabilitation had the strongest association with higher charges

  9. Center of Mass Compensation during Gait in Hip Arthroplasty Patients: Comparison between Large Diameter Head Total Hip Arthroplasty and Hip Resurfacing

    Directory of Open Access Journals (Sweden)

    Vicky Bouffard

    2011-01-01

    Full Text Available Objective. To compare center of mass (COM compensation in the frontal and sagittal plane during gait in patients with large diameter head total hip arthroplasty (LDH-THA and hip resurfacing (HR. Design. Observational study. Setting. Outpatient biomechanical laboratory. Participants. Two groups of 12 patients with LDH-THA and HR recruited from a larger randomized study and 11 healthy controls. Interventions. Not applicable. Main Outcome Measures. To compare the distance between the hip prosthetic joint center (HPJC and the COM. The ratio (RHPJC-COM and the variability (CVHPJC-COM were compared between groups. Hip flexor, abductor, and adductor muscle strength was also correlated between groups while radiographic measurements were correlated with the outcome measures. Results. In the frontal plane, HR shows less variability than healthy controls at push-off and toe-off and RHPJC-COM is correlated with the muscle strength ratios (FRABD at heel contact, maximal weight acceptance, and mid stance. In the sagittal plane, LDH-THA has a higher RHPJC-COM than healthy controls at push-off, and CVHPJC-COM is significantly correlated with FRFLEX. Conclusions. One year after surgery, both groups of patients, LDH-THA and HR, demonstrate minor compensations at some specific instant of the gait cycle, in both frontal and sagittal planes. However, their locomotion pattern is similar to the healthy controls.

  10. Recovery in mechanical muscle strength following resurfacing vs standard total hip arthroplasty - a randomised clinical trial

    DEFF Research Database (Denmark)

    Jensen, Carsten; Aagaard, Per; Overgaard, S

    2011-01-01

    rather than implant design per se. Thus, the present data failed to support the hypothesis that R-THA would result in an enhanced strength rehabilitation compared to S-THA. Further, between-limb asymmetry remained present for hip flexors and adductors after 52 wks. Trial registration: NCT01229293....... randomised into (A) standard total hip arthroplasty (S-THA) and (B) resurfacing total hip arthroplasty (R-THA). Pre-surgery assessment and follow-up were conducted (8, 26 and 52 wks). Maximal isometric muscle strength (Nm) and between-limb asymmetry for the knee extensors/flexors, hip adductors....../abductors, hip extensors/flexors were analysed. RESULTS: Maximal knee extensor and hip abductor strength were higher in S-THA than R-THA at 52 wks post-surgery (P ≤ 0.05) and hip extensors tended to be higher in S-THA at 52 wks (P = 0.06). All muscle groups showed substantial between-limb strength asymmetry (7...

  11. Acetabular Cup Revision.

    Science.gov (United States)

    Kim, Young-Ho

    2017-09-01

    The use of acetabular cup revision arthroplasty is on the rise as demands for total hip arthroplasty, improved life expectancies, and the need for individual activity increase. For an acetabular cup revision to be successful, the cup should gain stable fixation within the remaining supportive bone of the acetabulum. Since the patient's remaining supportive acetabular bone stock plays an important role in the success of revision, accurate classification of the degree of acetabular bone defect is necessary. The Paprosky classification system is most commonly used when determining the location and degree of acetabular bone loss. Common treatment options include: acetabular liner exchange, high hip center, oblong cup, trabecular metal cup with augment, bipolar cup, bulk structural graft, cemented cup, uncemented cup including jumbo cup, acetabular reinforcement device (cage), trabecular metal cup cage. The optimal treatment option is dependent upon the degree of the discontinuity, the amount of available bone stock and the likelihood of achieving stable fixation upon supportive host bone. To achieve successful acetabular cup revision, accurate evaluation of bone defect preoperatively and intraoperatively, proper choice of method of acetabular revision according to the evaluation of acetabular bone deficiency, proper technique to get primary stability of implant such as precise grafting technique, and stable fixation of implant are mandatory.

  12. Regional uptake an variations in orthopaedic enhanced recovery pathways in knee and hip total arthroplasty.

    Science.gov (United States)

    Mawdsley, M J; Baker, P N; Desai, A; Green, R N; Jevons, L

    2016-05-01

    The use of enhanced recovery (ER) pathways for hip and knee arthroplasty has increased over the last decade, and the adoption within orthopaedics is becoming more common. We have demonstrated a regional variation and institutional inconsistency of uptake and delivery of ER pathways in our region. Units that have a unified pathway were more likely to have consistency in treatment and early analgesia for patients. We would advocate that units use an agreed enhanced recovery pathway to optimise patient recovery from hip and knee arthroplasties.

  13. Patterns of functional improvement after revision knee arthroplasty.

    Science.gov (United States)

    Ghomrawi, Hassan M K; Kane, Robert L; Eberly, Lynn E; Bershadsky, Boris; Saleh, Khaled J

    2009-12-01

    Despite the increase in the number of total knee arthroplasty revisions, outcomes of such surgery and their correlates are poorly understood. The aim of this study was to characterize patterns of functional improvement after revision total knee arthroplasty over a two-year period and to investigate factors that affect such improvement patterns. Three hundred and eight patients in need of revision surgery were enrolled into the study, conducted at seventeen centers, and 221 (71.8%) were followed for two years. Short Form-36 (SF-36), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and Lower-Extremity Activity Scale (LEAS) scores were collected at baseline and every six months for two years postoperatively. A piecewise general linear mixed model, which models correlation between repeated measures and estimates separate slopes for different follow-up time periods, was employed to examine functional improvement patterns. Separate regression slopes were estimated for the zero to twelve-month and the twelve to twenty-four-month periods. The slopes for zero to twelve months showed significant improvement in all measures in the first year. The slopes for twelve to twenty-four months showed deterioration in the scores of the WOMAC pain subscale (slope = 0.67 +/- 0.21, p coefficient = -5.46 +/- 1.91, p coefficient = 5.41 +/- 2.35, p coefficient = 1.42 +/- 0.69, p < 0.05]). Factors related to the surgical technique did not predict outcomes. The onset of worsening pain and knee-specific function in the second year following revision total knee arthroplasty indicates the need to closely monitor patients, irrespective of the mode of failure of the primary procedure or the surgical technique for the revision. This information may be especially important for patients with multiple comorbidities.

  14. The efficacy of modified direct lateral versus posterior approach on gait function and hip muscle strength after primary total hip arthroplasty at 12months follow-up

    DEFF Research Database (Denmark)

    Rosenlund, Signe; Broeng, Leif; Overgaard, Søren

    2016-01-01

    -spatial parameters and range of motion. Isometric maximal hip muscle strength in abduction, flexion and extension was also tested. FINDINGS: Post-operatively, no between-group difference in gait function was observed. However, both hip abductor and flexor muscle strength improved more in the posterior approach group......BACKGROUND: The lateral and the posterior approach are the most commonly used procedures for total hip arthroplasty. Due to the detachment of the hip abductors, lateral approach is claimed to cause reduced hip muscle strength and altered gait pattern. However, this has not been investigated...... in a randomised controlled trial. The aim was to compare the efficacy of total hip arthroplasty performed by lateral or posterior approach on gait function and hip muscle strength up to 12months post-operatively. We hypothesised that posterior approach would be superior to lateral approach. METHODS: Forty...

  15. Epsilon Aminocaproic Acid to Reduce Blood Loss and Transfusion After Total Hip and Total Knee Arthroplasty.

    Science.gov (United States)

    Hobbs, Juliann C; Welsby, Ian J; Green, Cynthia L; Dhakal, Ishwori B; Wellman, Samuel S

    2018-01-01

    Total hip and knee arthroplasty (THA and TKA) are associated with significant blood loss and some patients require postoperative blood transfusion. While tranexamic acid has been studied extensively among this population, we tested the hypothesis that epsilon aminocaproic acid (EACA) can reduce blood loss and transfusion after joint arthroplasty. In April 2014, our Veterans Affairs Medical Center introduced a protocol to administer EACA during THA and TKA. No antifibrinolytics were used previously. We retrospectively compared blood loss and incidence of transfusion among patients who underwent primary arthroplasty in the year before standardized administration of EACA with patients having the same procedures the following year. Blood loss was measured as delta hemoglobin (preoperative hemoglobin - hemoglobin on postoperative day 1). All patients undergoing primary THA or TKA were included. Patients having revision surgery were excluded. We identified 185 primary arthroplasty patients from the year before and 184 from the year after introducing the EACA protocol. There were no changes in surgical technique or attending surgeons during this period. Delta hemoglobin was significantly lower in the EACA group (2.7 ± 0.8 mg/dL) compared to the control group (3.4 ± 1.1 mg/dL) (P blood transfusion was also significantly lower in the EACA group (2.7%) compared to the control group (25.4%) (P transfusion following introduction of the EACA protocol in patients undergoing primary arthroplasty. EACA offers a lower cost alternative to TXA for reducing blood loss and transfusion in this population. Published by Elsevier Inc.

  16. Total femur arthroplasty for revision hip failure in osteogenesis imperfecta: limits of biology

    Directory of Open Access Journals (Sweden)

    Pablo Sanz-Ruiz, PhD, MD

    2017-09-01

    Full Text Available Osteogenesis imperfecta (OI is a rare congenital disease characterized by alterations in bone quality, with susceptibility to fractures, instability, deformities, and osteoarthrosis. Prosthetic surgery in these patients is associated with an abnormally high rate of implant failures. On the other hand, abnormal bone fragility adds to the complexity of revision surgery in such individuals—thus representing a genuine challenge for the orthopaedic surgeon. We present a case of femoral reconstruction in a patient with OI and prosthetic loosening after reconstruction secondary to femoral septic pseudoarthrosis. Intramedullary total femoral reconstruction was carried out after exceeding the biological reconstruction limits. This is the first reported instance of the use of an intramedullary total femur arthroplasty as salvage technique in an OI patient. This technique should be considered when we have exceeded biological limits for femoral fixation.

  17. The crescent sign: dissociation of the polyethylene liner from a modular acetabular component in total hip arthroplasty

    International Nuclear Information System (INIS)

    White, S.P.; Blom, A.W.; Lee, M.; Smith, E.J.

    2005-01-01

    To study whether there was a common pattern of clinical symptoms, signs and radiographic features for the dissociation of the polyethylene liner from an acetabular component and to postulate reasons for these features. Retrospective study of notes and radiographs of cases of revision hip arthroplasty for polyethylene liner dissociation of the cementless Harris-Galante I porous-coated acetabular component (Zimmer Inc, Warsaw, IN) at the Avon Orthopaedic Centre, Bristol, UK and St. Mary's Hospital, Bristol, UK between 1995 and 2004. Patients were contacted to confirm preoperative symptoms. Nine cases of late polyethylene liner dissociation of this prosthesis have been revised in these institutions. All patients presented with a reduction in mobility, groin pain and limp. Eight patients reported an audible noise on hip movement. In all cases, radiographs showed radiolucency medial to the femoral neck in association with an eccentrically placed femoral head showing contact with the acetabular metal shell, which we have termed the ''crescent sign.'' There is a typical clinical presentation in this study. The diagnosis can be made from a single anteroposterior pelvic radiograph without the need for previous films for comparison, or the need for arthrography. Clinicians should look specifically for the crescent sign when an eccentrically placed femoral head has been noted, in order to differentiate the more unusual diagnosis of dissociation from that of polyethylene wear. Early revision surgery can prevent damage to the femoral head and metal acetabular shell, thus reducing the complexity of revision surgery. (orig.)

  18. Outcomes and weight-bearing status during rehabilitation after arthroplasty for hip fractures.

    Science.gov (United States)

    Siebens, Hilary C; Sharkey, Phoebe; Aronow, Harriet U; Horn, Susan D; Munin, Michael C; DeJong, Gerben; Smout, Randall J; Radnay, Craig S

    2012-08-01

    To examine the association of weight-bearing status with patient-related variables and outcomes of inpatient rehabilitation after hip arthroplasty for acute hip fracture. A multi-site prospective observational cohort study. Eighteen skilled nursing and inpatient rehabilitation facilities. Patients with hip fractures (N = 224) treated with hip arthroplasty and admitted to either skilled nursing or inpatient rehabilitation facilities; a subset (N = 84) with telephone follow-up outcomes 8 months after rehabilitation discharge. Measurements included demographic variables, medical severity using the Comprehensive Severity Index, and functional levels using the Functional Independence Measure. MAIN OUTCOMES MEASUREMENT: Cognitive, motor, and total Functional Independence Measure scores at rehabilitation discharge and at 8-month follow-up; living location at discharge and follow-up. Patients on average (standard deviation) were 76.8 ± 11.4 years old, mainly women (78%), and mainly white (87%). In unadjusted analysis, weight bearing as tolerated (WBAT) was associated with less osteoarthritis (P = .025) and lower admission medical severity (ACSI) (P = .014). One participating facility had a significant preponderance of restricted weight-bearing cases. WBAT had no bivariate association with cognitive or motor function at discharge. Therapists cited restricted weight bearing as a barrier to therapy in 11% of cases. In logistic regressions, lower medical admission severity, older age, and one specified site significantly predicted WBAT (c statistic = 0.714). Significant predictors for home discharge included lower maximum severity (P < .001), younger age (P < .001), higher cognition (P = .037), and WBAT (P = .051) (c statistic = 0.863). WBAT is associated with a greater likelihood of home discharge and had similar functional outcomes compared with restricted weight bearing. These findings add support for allowing WBAT after arthroplasty for hip fracture. Copyright © 2012

  19. Subacute pain and function after fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Andersen, Lasse Østergaard; Gaarn-Larsen, L; Kristensen, B B

    2009-01-01

    In a well-defined fast-track setup for total hip and knee arthroplasty, with a multimodal analgesic regimen consisting of intra-operative local anaesthetic infiltration and oral celecoxib, gabapentin and paracetamol for 6 days postoperatively, we conducted a prospective, consecutive, observationa...

  20. Preoperative ambulatory measurement of asymmetric leg loading during sit-to-stand in hip arthroplasty patients

    NARCIS (Netherlands)

    Martinez-Ramirez, A.; Weenk, D.; Lecumberri, P.; Verdonschot, N.J.; Pakvis, D.; Veltink, P.H.

    2014-01-01

    Total hip arthroplasty (TGA) is a successful surgical procedure to treat patients with hip osteoarthritis. Clinicians use different questionnaires to evaluate these patients. Gait velocity and these questionnaires; usually show significant improvement after TGA . This clinical evaluation does,

  1. Does BMI influence hospital stay and morbidity after fast-track hip and knee arthroplasty?

    DEFF Research Database (Denmark)

    Husted, Henrik; Jørgensen, Christoffer C; Gromov, Kirill

    2016-01-01

    Background and purpose - Body mass index (BMI) outside the normal range possibly affects the perioperative morbidity and mortality following total hip arthroplasty (THA) and total knee arthroplasty (TKA) in traditional care programs. We determined perioperative morbidity and mortality in such pat......Background and purpose - Body mass index (BMI) outside the normal range possibly affects the perioperative morbidity and mortality following total hip arthroplasty (THA) and total knee arthroplasty (TKA) in traditional care programs. We determined perioperative morbidity and mortality...... in such patients who were operated with the fast-track methodology and compared the levels with those in patients with normal BMI. Patients and methods - This was a prospective observational study involving 13,730 procedures (7,194 THA and 6,536 TKA operations) performed in a standardized fast-track setting....... Complete 90-day follow-up was achieved using national registries and review of medical records. Patients were grouped according to BMI as being underweight, of normal weight, overweight, obese, very obese, and morbidly obese. Results - Median length of stay (LOS) was 2 (IQR: 2-3) days in all BMI groups. 30...

  2. Bearing Change to Metal-On-Polyethylene for Ceramic Bearing Fracture in Total Hip Arthroplasty; Does It Work?

    Science.gov (United States)

    Lee, Soong Joon; Kwak, Hong Suk; Yoo, Jeong Joon; Kim, Hee Joong

    2016-01-01

    We evaluated the short-term to midterm results of reoperation with bearing change to metal-on-polyethylene (MoP) after ceramic bearing fracture in ceramic-on-ceramic total hip arthroplasty. Nine third-generation ceramic bearing fractures (6 heads and 3 liners) were treated with bearing change to MoP. Mean age at reoperation was 52.7 years. Mean follow-up was 4.3 years. During follow-up, 2 of 3 liner-fractured hips and 1 of 6 head-fractured hips showed radiologic signs of metallosis and elevated serum chromium levels. Re-reoperation with bearing rechange to a ceramic head was performed for the hips with metallosis. One liner-fractured hip had periprosthetic joint infection. Dislocation occurred in 3 hips. From our experience, bearing change to MoP is not a recommended treatment option for ceramic bearing fracture in total hip arthroplasty. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. P-Selectin: An Unpredicted Factor for Deep Vein Thrombosis after Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Dongquan Shi

    2014-01-01

    Full Text Available Introduction. Deep vein thrombosis (DVT is a severe complication after total hip arthroplasty (THA. It leads to acute pulmonary embolism, a life-threatening disease. P-selectin is a 140-kDa transmembrane glycoprotein. Elevated P-selectin was associated with 1.7-fold increase in the risk of venous thrombosis. Materials and Methods. To confirm the association, a total of 91 subjects who received primary total hip arthroplasty using lateral approach performed by one skilled orthopedic surgeon were studied. All the patients were consecutively enrolled at the Center of Diagnosis and Treatment for Joint Diseases, Drum Tower Hospital affiliated to the Medical School of Nanjing University from 2010 to 2012. All the subjects received venography 3–5 days after operation. We measured P-selectin by means of a highly sensitive sandwich ELISA technique and a commercially available test reagent set. Results. No significant association was detected between P-selectin and DVT (all P  values>0.05. ΔsP-selectin was correlated with weight, APTT after operation, history of DVT, and diagnosis of primary disease ( P values were 0.03, 0.03, 0.04, and 0.02, resp.. Conclusion. P-selectin may not be a predicted factor for deep vein thrombosis after total hip arthroplasty.

  4. Ultrasound-guided Radiofrequency Lesioning of the Articular Branches of the Femoral Nerve for the Treatment of Chronic Post-arthroplasty Hip Pain.

    Science.gov (United States)

    Kim, David J; Shen, Shiqian; Hanna, George M

    2017-02-01

    Total hip arthroplasty (THA) is a common surgical treatment for several conditions of the hip. While the majority of patients obtain satisfactory results, many develop chronic post-arthroplasty hip pain that can be difficult to treat. We evaluate the effectiveness of cooled (60°C) radiofrequency lesioning of the articular branches of the femoral nerve (ABFN) as a minimally invasive treatment for patients suffering from chronic post-arthroplasty hip pain. This treatment has never been described previously in this population. Case report. Center for Pain Medicine, Massachusetts General Hospital, Harvard Medical School. A 59-year-old woman with long-standing osteoarthritis of the right hip who underwent primary total hip arthroplasty and presented with chronic post-arthroplasty hip pain Intervention: Cooled (60°C) radiofrequency lesioning of the ABFN under ultrasound guidance Outcome Measure: Functional ability and numeric rating scale (NRS) scores at rest and with activity. Prior to intervention, the patient reported severe disruption in daily activities, sleep, and relationships; NRS scores at rest and with activity were 4/10 and 10/10, respectively. At 4 weeks following intervention, the patient reported significant improvement in functional ability and NRS scores decreased to 1/10 and 2/10, respectively. At 6 months, the patient's NRS scores at rest and with activity were 0/10 and 1/10, respectively. At 24-month follow-up, the patient continued to endorse significant pain relief with NRS scores at rest and with activity of 0 - 1/10 and 1 - 2/10, respectively. There were no side effects or complications including motor weakness, sensory loss, and neuralgias. Although the patient obtained good results from the intervention, the description of the study is from a single case report. Further study is necessary to investigate the widespread use of this technique and its outcomes. Cooled (60°C) radiofrequency lesioning of the ABFN under ultrasound guidance is both an

  5. Patient pain and blood management in total hip and knee arthroplasty

    NARCIS (Netherlands)

    Thomassen, Bregje J.W.

    2014-01-01

    What is already known on this topic: Local infiltration analgesia in combination with a multimodal pain approach helps for adequate postoperative pain control. Blood saving alternatives should be implemented in the process of primary total hip and knee arthroplasties. The endpoint in patient

  6. Patient compliance with extended low molecular weight heparin injections following hip and knee arthroplasty.

    Science.gov (United States)

    Deakin, Dan E; Mishreki, Andrew; Aslam, Nadim; Docker, Charles

    2010-01-01

    The use of extended duration thromboprophylaxis following hip and knee arthroplasty is becoming widespread. The aim of our study was to determine patient compliance with extended duration thromboprophylaxis using low molecular weight (LMWH) injections following hip and knee arthroplasty. 42 consecutive patients undergoing hip and knee arthroplasty were prospectively contacted during their fifth post operative week. A fully anonymised questionnaire was completed by each patient. All patients responded. One was excluded having been prescribed warfarin for pre existing atrial fibrillation. Twenty nine (71%) patients were discharged with the intention of self administering LMWH injections. Eight (20%) and four (9%) patients were discharged with the intention of administration by a relative or district nurse respectively. No patient required the person administering the injections to be changed after discharge from hospital. 90% (n=37) of patients reported not missing any doses. 10% (n=2) of patients missed one dose and 10% (n=2) missed two doses. Patient compliance with extended duration thromboprophylaxis using LMWH injections is extremely high. Oral thromboprophylaxis may be useful in the minority of patients requiring daily visits by a nurse to administer injections.

  7. Poorer survival after a primary implant during revision total knee arthroplasty

    NARCIS (Netherlands)

    Meijer, Marrigje F.; Reininga, Inge H. F.; Boerboom, Alexander L.; Stevens, Martin; Bulstra, Sjoerd K.

    Revision total knee arthroplasty (rTKA) is a complex procedure. Depending on the degree of ligament and bone damage, either primary or revision implants are used. The purpose of this study was to compare survival rates of primary implants with revision implants when used during rTKA. A retrospective

  8. Is etoricoxib effective in preventing heterotopic ossification after primary total hip arthroplasty?

    NARCIS (Netherlands)

    Brunnekreef, J.J.; Hoogervorst, P.; Ploegmakers, M.J.M.; Rijnen, W.H.C.; Schreurs, B.W.

    2013-01-01

    PURPOSE: Heterotopic ossification is a common complication after total hip arthroplasty. Non-steroidal anti-inflammatory drugs (NSAIDs) are known to prevent heterotopic ossifications effectively, however gastrointestinal complaints are reported frequently. In this study, we investigated whether

  9. High-volume infiltration analgesia in bilateral hip arthroplasty

    DEFF Research Database (Denmark)

    Andersen, Lasse Ø; Otte, Niels Kristian Stahl; Husted, Henrik

    2011-01-01

    bilateral total hip arthroplasty (THA) in a fast-track setting, saline or high-volume (170 mL) ropivacaine (0.2%) with epinephrine (1:100,000) was administered to the wound intraoperatively along with supplementary postoperative injections via an intraarticular epidural catheter. Oral analgesia...... was instituted preoperatively with a multimodal regimen (gabapentin, celecoxib, and acetaminophen). Pain was assessed repeatedly for 48 hours postoperatively, at rest and with 45° hip flexion. Results Pain scores were low and similar between ropivacaine and saline administration. Median hospital stay was 4...... (range 2-7) days. Interpretation Intraoperative high-volume infiltration with 0.2% ropivacaine with repeated intraarticular injections postoperatively may not give a clinically relevant analgesic effect in THA when combined with a multimodal oral analgesic regimen with gabapentin, celecoxib...

  10. Low Risk of Thromboembolic Events After Routine Administration of Tranexamic Acid in Hip and Knee Arthroplasty

    DEFF Research Database (Denmark)

    Madsen, Rune V; Nielsen, Christian S.; Kallemose, Thomas

    2017-01-01

    BACKGROUND: The blood-conserving effect of intravenous (IV) tranexamic acid (TXA) is well-documented for total hip arthroplasty (THA) and total knee arthroplasty (TKA). However, the risk of thromboembolic (TE) events after routine use of TXA is unclear and the safety profile is debated...

  11. Pseudotumor from Metal-on-Metal Total Hip Arthroplasty Causing Unilateral Leg Edema: Case Presentation and Literature Review

    Directory of Open Access Journals (Sweden)

    Caleb W. Grote

    2018-03-01

    Full Text Available Metal-on-metal (MoM total hip arthroplasty (THA can be associated with adverse metal reactions, including pseudotumors. This case report describes a 58-year-old female with an MoM THA-related pseudotumor that caused unilateral leg edema from compression of her external iliac vein. After thorough preoperative workup to rule out infection and deep vein thrombosis and consultation with a vascular surgeon, the patient underwent revision THA and excision of her pseudotumor. She had complete resolution of her swelling at 4 years after surgery. Review of all available case reports for this rare complication revealed that almost all patients were female. All patients underwent revision THA, with resolution of their symptoms. Literature review demonstrates that women are disproportionally affected by complications associated with MoM THA. We recommend close monitoring of patients with MoM THA, particularly women, for development of adverse metal reactions.

  12. Fracture of Fully-coated Femoral Stem after Primary Total Hip Arthroplasty for Nonunion of Intertrochanteric Fracture: A Case Report.

    Science.gov (United States)

    Chun, Young Soo; Juh, Hyung Suk; Cho, Yoon Je; Rhyu, Kee Hyung

    2015-09-01

    Femoral stem fracture is an uncommon reason for the failure of total hip arthroplasty, with only 16 cases of fully coated stem fractures reported to date. Here we report a case in which a fully coated primary femoral stem fracture occurred after conversion to total hip arthroplasty for the non-union of an intertrochanteric fracture of the femur. Metallurgic evaluation of the etiology and mechanism revealed that the fracture was initiated by fatigue-related failure and completed by ductile failure on the posterior side of the fracture. Considering the recent trend of treating an intertrochanteric fracture with hip arthroplasty, possible stem failure should be considered, since most patients will have at least one of the known risk factors for stem fracture.

  13. Warfarin for venous thromboembolism prophylaxis after elective hip or knee arthroplasty: exploring the evidence, guidelines, and challenges remaining.

    Science.gov (United States)

    Dager, William E

    2012-01-01

    Guidelines for the prevention of venous thromboembolism (VTE) after elective total hip or knee arthroplasty (THA/TKA) have been developed separately by the American Academy of Orthopaedic Surgeons (AAOS) and the American College of Chest Physicians (ACCP). Differences exist in approaches to preventing postoperative VTE through prophylaxis. To compare trials using vitamin K antagonists (VKAs) and differences in guidelines to determine the benefits and drawbacks of warfarin for VTE prophylaxis following THA/TKA. Guidelines from the AAOS published in 2009 and revised in 2011 and from the ACCP published in 2008 were compared for recommendations on the use of VKAs. A MEDLINE search from 1960 to November 2009 was conducted to identify pertinent articles on the use of warfarin or VKAs for VTE prophylaxis following THA/TKA. Search terms included warfarin, vitamin K antagonist, total hip or total knee replacement, and total hip or total knee arthroplasty. Only clinical trials in which warfarin was the primary agent for prophylaxis compared to other anticoagulants were included. Data on differences between guideline recommendations for the use of VKAs and the importance of a deep vein thrombosis or asymptomatic events were extracted. Thirteen comparative trials using VKAs for VTE prophylaxis and international normalized ratio (INR) targets were assessed. Overall, the incidence of bleeding tended to be lower with the use of VKAs, but thrombosis when including asymptomatic events was numerically higher when comparing INR targets. However, INR targets varied, with no comparative trials assessing the AAOS 2009 recommended INR target of 1.5-2.0. The AAOS guidelines initially recommended a longer duration of therapy and expressed stronger support for the use of aspirin for prophylaxis; however, in 2011, its guidelines were revised, with no specific recommendations as to agent, dose, or INR target goal. Warfarin is an effective agent to prevent VTE after elective THA/TKA. The most

  14. Innovations in design and technology. The story of hip arthroplasty.

    Science.gov (United States)

    Amstutz, H C

    2000-09-01

    The current study reviews the early history of surgeon-initiated trial and error development in hip joint arthroplasty and the subsequent methodological evolution to proper criteria for hypothesis testing using bioengineers and other research scientists. The interplay and relationships to industry, universities, scientific organizations, and the Food and Drug Administration with respect to device development in hip arthroplasty are reviewed. The ethics of and responsibilities to involved parties are outlined, citing the history of many contemporary developments. Examples are provided from the evolution and introduction of unsuccessful innovations, and the problems inherent in the current methodology of the approval process from the Food and Drug Administration using the 5-10K, Investigative Device Exemption, and the Pre-Market Approval protocols. The pros and cons of randomized trials for devices are outlined with the conclusion that they are not appropriate for device introduction. The proper, rational methodology for introduction of new devices is a phased-in clinical trial process after pertinent bench testing. Finally, the ethical dilemmas created by managed care are addressed. Industry involvements of the surgeon-spokesmen are cited.

  15. The threshold force required for femoral impaction grafting in revision hip surgery.

    LENUS (Irish Health Repository)

    Flannery, Olivia M

    2010-06-01

    BACKGROUND AND PURPOSE: Femoral impaction grafting requires vigorous impaction to obtain adequate stability without risk of fracture, but the force of impaction has not been determined. We determined this threshold force in a preliminary study using animal femurs. METHODS: Adult sow femurs were used because of their morphological similarity to human femurs in revision hip arthroplasty. 35 sow femurs were impacted with morselized bone chips and an increasing force was applied until the femur fractured. This allowed a threshold force to be established. 5 other femurs were impacted to this force and an Exeter stem was cemented into the neomedullary canal. A 28-mm Exeter head was attached and loaded by direct contact with a hydraulic testing machine. Axial cyclic loading was performed and the position sensor of the hydraulic testing machine measured the prosthetic head subsidence. RESULTS: 29 tests were completed successfully. The threshold force was found to be 4 kN. There was no statistically significant correlation between the load at fracture and the cortex-to-canal ratio or the bone mineral density. Following impaction with a maximum force of 4 kN, the average axial subsidence was 0.28 mm. INTERPRETATION: We achieved a stable construct without fracture. Further studies using human cadaveric femurs should be done to determine the threshold force required for femoral impaction grafting in revision hip surgery.

  16. The influence of heterotopic ossification on functional status of hip joint following total hip arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Pohl, F.; Seufert, J.; Flentje, M.; Koelbl, O. [Wuerzburg Univ. (Germany). Dept. of Radiotherapy; Tauscher, A.; Springorum, H.W. [Caritas Krankenhaus Bad Mergentheim (Germany). Orthopedic Clinic; Lehmann, H. [Caritas Krankenhaus Bad Mergentheim (Germany). Inst. of Radiology

    2005-08-01

    Purpose: The functional failure induced by heterotopic ossification (HO) following total hip arthroplasty (THA) was analyzed and correlated to the radiologic failure. Patients and methods: From July 1997 to July 2001, 315 patients (345 hips) received THA indicated by a hypertrophic osteoarthritis of higher degree (Kellgren grade III, IV). All patients were irradiated prophylactically for prevention of HO on the evening before surgery with a 7-Gy single fraction. The patients' median age was 66.3 years. Radiologic failure was assessed by comparison of pre- and postoperative hip X-rays (immediately and 6 months after surgery). Analysis of radiographs was performed according to the Brooker Score. Clinical failure was appraised by measurement of passive range of motion (ROM) of the hip joint with a standard goniometer. The t-test was used for statistical analysis. Results: 281 patients (81.5%) did not develop HO. HO of Brooker grade I or II was found in 58 patients (16.8%). Six patients (1.7%) developed HO Brooker grade III or IV. There was a significant negative correlation between the degree of radiologic and clinical failure. ROM differed significantly between patients with HO Brooker grade 0, I, II and patients with HO Brooker grade III, IV. Comparing the pre- and postoperative ROM, all patients with Brooker grade 0, I and II showed a significant improvement of flexion, internal and external rotation, abduction and adduction movement. Patients with HO Brooker grade III and IV showed no improvement of ROM in the postoperative follow-up. Conclusion: The development of HO following THA influences the physical function of the hip joint dependent on the degree of ossification. HO of lower degree (Brooker I, II) does not influence the clinical outcome, whereas HO of higher degree (Brooker III, IV) reduces the function of hip arthroplasty. Therefore, the purpose of a prophylactic therapy must be to reduce HO of higher degree. (orig.)

  17. Incidence of perioperative complications in total hip and knee arthroplasty in patients with Parkinson disease.

    Science.gov (United States)

    Sharma, Tankamani; Hönle, Wolfgang; Handschu, René; Adler, Werner; Goyal, Tarun; Schuh, Alexander

    2018-06-01

    The aim of this study is to evaluate the difference in perioperative complication rate in total hip, bipolar hemiarthroplasties and total knee arthroplasty in patients with Parkinson disease in trauma and elective surgery in our Musculoskeletal Center during a period of 10 years. Between 2006 and 2016, 45 bipolar hemiarthroplasties in trauma surgery, 15 total knee and 19 total hip arthroplasties in patients with Parkinson's disease were performed. We divided the patients in two groups. Group I included trauma cases (45) and group II elective surgery cases (34). Complications were documented and divided into local minor and major complications and general minor and major complications. Fisher's exact test was used for statistical evaluation. In both groups, there was one local major complication (p > 0.05): In group I, there was one case of loosening of a K-wire which was removed operatively. In group II, there was one severe intraarticular bleeding requiring puncture of the hematoma. In group I, there were 38 general complications; in group II, there were 17 general complications. There was no statistical difference in complication rate (p > 0.05). Total hip arthroplasty, bipolar hemiarthroplasties and knee arthroplasty in patients with Parkinson disease is possible in elective and trauma surgery. Complication rate is higher in comparison with patients not suffering from Parkinson disease, but there is no difference in complication rate in elective and trauma surgery. Nevertheless, early perioperative neurological consultation in patients with Parkinson disease is recommended to minimize complications and improve early outcomes after arthroplasty.

  18. Activity, Sleep and Cognition After Fast-Track Hip or Knee Arthroplasty

    DEFF Research Database (Denmark)

    Krenk, Lene; Jennum, Poul; Kehlet, Henrik

    2013-01-01

    Optimized perioperative care after total hip and knee arthroplasty (THA/TKA) has decreased length of stay (LOS) but data on activity, sleep and cognition after discharge are limited. We included 20 patients ≥60years undergoing THA/TKA, monitoring them for 3days preoperatively and 9days...

  19. Early Clinical and Radiographic Results of Minimally Invasive Anterior Approach Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Tamara Alexandrov

    2014-01-01

    consecutive patients with 43 total hip arthroplasties performed through an anterior muscle sparing minimally invasive approach. We found the early complication rates and radiographic outcomes comparable to those reported from arthroplasties performed via traditional approaches. Complications included dislocation (2%, femur fracture (2%, greater trochanteric fracture (12%, postoperative periprosthetic intertrochanteric fracture (2%, femoral nerve palsy (5%, hematoma (2%, and postoperative iliopsoas avulsion (2%. Radiographic analysis revealed average cup anteversion of 19.6°±6.6, average cup abduction angle of 48.4°±7, stem varus of 0.9°±2, and a mean leg length discrepancy of 0.7 mm. The anterior approach to the hip is an attractive alternative to the more traditional approaches. Acceptable component placement with comparable complication rates is possible using a muscle sparing technique which may lead to faster overall recovery.

  20. Lifestyle and health-related quality of life in Asian patients with total hip arthroplasties.

    Science.gov (United States)

    Fujita, Kimie; Xia, Zhenlan; Liu, Xueqin; Mawatari, Masaaki; Makimoto, Kiyoko

    2014-09-01

    Total hip arthroplasty reduces pain and restores physical function in patients with hip joint problems. This study examined lifestyle and health-related quality of life before and after total hip arthroplasty in Japanese and Chinese patients. Two hospitals in China recruited 120 patients and 120 Japanese patients matched by age and operative status were drawn from a prospective cohort database. Oxford Hip Score, EuroQol, and characteristics of Asian lifestyle and attitudes toward the operation were assessed. There were no differences between patients from the two countries in quality-of-life-scale scores: postoperative patients had significantly better quality-of-life scores than preoperative patients in both countries. In China, patients who reported that living at home was inconvenient had significantly worse Oxford Hip Scores than those who did not. Mean scores for anxiety items concerning possible dislocation and durability of the implant were significantly higher in Japanese than in Chinese subjects. Our findings suggest that providing information about housing conditions and lifestyles would result in improved quality of life and reduced anxiety in patients with implanted joints. © 2014 Wiley Publishing Asia Pty Ltd.

  1. Effects of the Length of Stay on the Cost of Total Knee and Total Hip Arthroplasty from 2002 to 2013.

    Science.gov (United States)

    Molloy, Ilda B; Martin, Brook I; Moschetti, Wayne E; Jevsevar, David S

    2017-03-01

    Utilization of total knee and hip arthroplasty has greatly increased in the past decade in the United States; these are among the most expensive procedures in patients with Medicare. Advances in surgical techniques, anesthesia, and care pathways decrease hospital length of stay. We examined how trends in hospital cost were altered by decreases in length of stay. Procedure, demographic, and economic data were collected on 6.4 million admissions for total knee arthroplasty and 2.8 million admissions for total hip arthroplasty from 2002 to 2013 using the National (Nationwide) Inpatient Sample, a component of the Healthcare Cost and Utilization Project. Trends in mean hospital costs and their association with length of stay were estimated using inflation-adjusted, survey-weighted generalized linear regression models, controlling for patient demographic characteristics and comorbidity. From 2002 to 2013, the length of stay decreased from a mean time of 4.06 to 2.97 days for total knee arthroplasty and from 4.06 to 2.75 days for total hip arthroplasty. During the same time period, the mean hospital cost for total knee arthroplasty increased from $14,988 (95% confidence interval [CI], $14,927 to $15,049) in 2002 to $22,837 (95% CI, $22,765 to $22,910) in 2013 (an overall increase of $7,849 or 52.4%). The mean hospital cost for total hip arthroplasty increased from $15,792 (95% CI, $15,706 to $15,878) in 2002 to $23,650 (95% CI, $23,544 to $23,755) in 2013 (an increase of $7,858 or 49.8%). If length of stay were set at the 2002 mean, the growth in cost for total knee arthroplasty would have been 70.8% instead of 52.4% as observed, and the growth in cost for total hip arthroplasty would have been 67.4% instead of 49.8% as observed. Hospital costs for joint replacement increased from 2002 to 2013, but were attenuated by reducing inpatient length of stay. With demographic characteristics showing an upward trend in the utilization of joint arthroplasty, including a shift

  2. Chronic pain following total hip arthroplasty: a nationwide questionnaire study

    DEFF Research Database (Denmark)

    Nikolajsen, Lone; Brandsborg, Birgitte; Lucht, Ulf

    2006-01-01

    BACKGROUND: Chronic post-operative pain is a well-recognized problem after various types of surgery, but little is known about chronic pain after orthopedic surgery. Severe pre-operative pain is the primary indication for total hip arthroplasty (THA). Therefore, we examined the prevalence...... was 93.6%. Two hundred and ninety-four patients (28.1%) had chronic ipsilateral hip pain at the time of completion of the questionnaire, and pain limited daily activities to a moderate, severe or very severe degree in 12.1%. The chronic pain state was related to the recalled intensity of early post...

  3. Arthroplasty of hip resection, handling with external fixation - Experience in the central military hospital

    International Nuclear Information System (INIS)

    Satizabal Azuero, Carlos E; Calderon Uribe, Oscar; Naquira Escobar, Luis F

    2006-01-01

    This is an observational retrospective study series of cases carried out between January 1998 and July 2004 in the central military hospital, 13 patients were treated with Girdlestone arthroplasty with external fixation, with a pursuit average of 53 months. Function, return to the daily activities and associate complications was evaluated. They were as complication; pain in the fixator site, osteitis, and fixator broke. All patients report at the end of the treatment no pain in the hip. Shortening in the patient without lenghting was 3,5 cm and in the group with lenghting was 1.5 cm. the obtained results demonstrate that Girdlestone arthroplasty with external fixation, is option, to improve the patient's pain and function of the hip

  4. Risk factors for total hip arthroplasty aseptic revision.

    Science.gov (United States)

    Khatod, Monti; Cafri, Guy; Namba, Robert S; Inacio, Maria C S; Paxton, Elizabeth W

    2014-07-01

    The purpose of this study was to evaluate patient, operative, implant, surgeon, and hospital factors associated with aseptic revision after primary THA in patients registered in a large US Total Joint Replacement Registry. A total of 35,960 THAs registered from 4/2001-12/2010 were evaluated. The 8-year survival rate was 96.7% (95% CI 96.4%-97.0%). Females had a higher risk of aseptic revision than males. Hispanic and Asian patients had a lower risk of revision than white patients. Ceramic-on-ceramic, ceramic-on-conventional polyethylene, and metal-on-conventional polyethylene bearing surfaces had a higher risk of revision than metal-on-highly cross-linked polyethylene. Body mass index, health status, diabetes, diagnosis, fixation, approach, bilateral procedures, head size, surgeon fellowship training, surgeon and hospital volume were not revision risk factors. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Perioperative Allogeneic Red Blood-Cell Transfusion Associated with Surgical Site Infection After Total Hip and Knee Arthroplasty.

    Science.gov (United States)

    Everhart, Joshua S; Sojka, John H; Mayerson, Joel L; Glassman, Andrew H; Scharschmidt, Thomas J

    2018-02-21

    Perioperative allogeneic red blood-cell transfusion is a suspected risk factor for surgical site infection (SSI) after total joint arthroplasty (TJA), but the interrelationships among SSI risk, transfusion dose, preoperative anemia, and the presence of coagulopathies have not been well described. Data on SSI within 1 year after surgery as well as on transfusion with blood products within 30 days after surgery were obtained for 6,788 patients who had undergone primary or revision total hip or knee arthroplasty from 2000 to 2011 in a single hospital system. Multivariate logistic regression modeling was used to determine the independent association between allogeneic red blood-cell transfusion and SSI. There was a dose-dependent association between allogeneic red blood-cell transfusion and SSI, with the infection rate increasing as the transfusion dose increased from 1 unit (odds ratio [OR] = 1.97; 95% confidence interval [CI] = 1.38, 2.79; p 3 units (OR = 7.40; CI = 4.91, 11.03; p conservation strategies. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  6. Early subsidence of shape-closed hip arthroplasty stems is associated with late revision. A systematic review and meta-analysis of 24 RSA studies and 56 survival studies.

    Science.gov (United States)

    van der Voort, Paul; Pijls, Bart G; Nieuwenhuijse, Marc J; Jasper, Jorrit; Fiocco, Marta; Plevier, Josepha W M; Middeldorp, Saskia; Valstar, Edward R; Nelissen, Rob G H H

    2015-01-01

    Few studies have addressed the association between early migration of femoral stems and late aseptic revision in total hip arthroplasty. We performed a meta-regression analysis on 2 parallel systematic reviews and meta-analyses to determine the association between early migration and late aseptic revision of femoral stems. Of the 2 reviews, one covered early migration data obtained from radiostereometric analysis (RSA) studies and the other covered long-term aseptic revision rates obtained from survival studies with endpoint revision for aseptic loosening. Stems were stratified according to the design concept: cemented shape-closed, cemented force-closed, and uncemented. A weighted regression model was used to assess the association between early migration and late aseptic revision, and to correct for confounders. Thresholds for acceptable and unacceptable migration were determined in accordance with the national joint registries (≤ 5% revision at 10 years) and the NICE criteria (≤ 10% revision at 10 years). 24 studies (731 stems) were included in the RSA review and 56 studies (20,599 stems) were included in the survival analysis review. Combining both reviews for the 3 design concepts showed that for every 0.1-mm increase in 2-year subsidence, as measured with RSA, there was a 4% increase in revision rate for the shape-closed stem designs. This association remained after correction for age, sex, diagnosis, hospital type, continent, and study quality. The threshold for acceptable migration of shape-closed designs was defined at 0.15 mm; stems subsiding less than 0.15 mm in 2 years had revision rates of less than 5% at 10 years, while stems exceeding 0.15 mm subsidence had revision rates of more than 5%. There was a clinically relevant association between early subsidence of shape-closed femoral stems and late revision for aseptic loosening. This association can be used to assess the safety of shape-closed stem designs. The published research is not sufficient

  7. Clinical Usefulness of SPECT-CT in Patients with an Unexplained Pain in Metal on Metal (MOM) Total Hip Arthroplasty.

    Science.gov (United States)

    Berber, Reshid; Henckel, Johann; Khoo, Michael; Wan, Simon; Hua, Jia; Skinner, John; Hart, Alister

    2015-04-01

    SPECT-CT is increasingly used to assess painful knee arthroplasties. The aim of this study was to evaluate the clinical usefulness of SPECT-CT in unexplained painful MOM hip arthroplasty. We compared the diagnosis and management plan for 19 prosthetic MOM hips in 15 subjects with unexplained pain before and after SPECT-CT. SPECT-CT changed the management decision in 13 (68%) subjects, Chi-Square=5.49, P=0.24. In 6 subjects (32%) pain remained unexplained however the result reassured the surgeon to continue with non-operative management. SPECT-CT should be reserved as a specialist test to help identify possible causes of pain where conventional investigations have failed. It can help reassure surgeons making management decisions for patients with unexplained pain following MOM hip arthroplasty. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Total hip arthroplasty at the rothman institute.

    Science.gov (United States)

    Austin, Matthew S; Higuera, Carlos A; Rothman, Richard H

    2012-07-01

    Total hip arthroplasty (THA) is one of the most successful surgical interventions devised in modern times. Attempts to change the current THA procedure with unproven innovations bring the risk of increased failure rates while trying to improve the benefit of the surgery. This manuscript examines the evolution of THA at the Rothman Institute illustrating the key elements that lead the success of this procedure at this institution. These key elements include femoral stem design, use of highly crossed-linked polyethylene and use of pain and rehabilitation protocols. We attempted to describe the long-term results regarding safety, effectiveness, and durability of specific THA implant designs used at this institution drawing on reported evidence in the literature. The authors performed a review of peer-reviewed articles related to the Rothman Institute's experience with THA. Total hip arthroplasty is an efficient, safe, and durable procedure. It is a highly successful operation to restore function and improve pain. The survivorship of THA procedures at the Rothman Institute is higher than 99% at 10 years based on mechanical failure. The use of collarless, tapered wedge femoral stem, highly crossed-linked polyethylene, and improved pain rehabilitation protocols have contributed to this success. There is a well-documented long-term survivorship after THA. Future innovation in THA should address new challenges with younger and more demanding patients, rather than change current methods that have a proven good survivorship. This innovation depends mainly upon improvements in the bearing surfaces and advances in pain control and rehabilitation.

  9. Adaptive bone remodeling and biomechanical design considerations : for noncemented total hip arthroplasty

    NARCIS (Netherlands)

    Huiskes, H.W.J.; Weinans, H.; Dalstra, M.

    1989-01-01

    Clinical problems with noncemented total hip arthroplasty (THA) stems, directly or indirectly related to load transfer, include mid-thigh pain due to relative (micro) motions or excessive endosteal interface stresses, subsidence and loosening due to inadequate primary stability and fit, and proximal

  10. Total hip arthroplasty using a short-stem prosthesis: restoration of hip anatomy.

    Science.gov (United States)

    Amenabar, Tomas; Marimuthu, Kanniraj; Hawdon, Gabrielle; Gildone, Alessandro; McMahon, Stephen

    2015-04-01

    To evaluate hip parameters such as vertical centre of rotation (VCR), horizontal centre of rotation (HCR), femoral offset, and leg length after total hip arthroplasty (THA) using the Nanos short-stem prosthesis. Medical records of 73 men and 74 women aged 25 to 92 (mean, 63) years who underwent THA using the Nanos short-stem prosthesis by a single surgeon were reviewed. Prior to the surgery, the optimal cup and stem size, head length, and level of the neck osteotomy were determined using radiographs. Intra-operatively, the leg length and femoral offset were checked, and the level of neck resection and head length were adjusted. VCR, HCR, femoral offset, and leg length of the operated and contralateral sides were compared. Functional outcomes were assessed using the Harris Hip Score (HHS). Compared with the normal contralateral hips, the operated hips had a mean increase of 0.4 mm in VCR (p=0.032), a mean decrease of 1.4 mm in HCR (p=0.027), a mean increase of 0.6 mm in femoral offset (p=0.043), and a mean increase of 0.36 mm in leg length (p=0.035). For these respective parameters, the difference between the normal contralateral side and the operated side was within 5 mm in 89%, 80%, 71%, and 96% of patients. The HHS improved from a mean of 53 to 91 at one year (pNanos short-stem prosthesis enabled restoration of hip anatomy (VCR, HCR, femoral offset, and leg length).

  11. Predictors of excellent early outcome after total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Smith George H

    2012-03-01

    Full Text Available Abstract Background Not all patients gain the same degree of improvement from total hip replacement and the reasons for this are not clear. Many investigators have assessed predictors of general outcome after hip surgery. This study is unique in its quest for the predictors of the best possible early outcome. Methods We prospectively collected data on 1318 total hip replacements. Prior to surgery patient characteristics, demographics and co-morbidities were documented. Hip function and general health was assessed using the Harris Hip score (HHS and the Short-Form 36 respectively. The HHS was repeated at three years. We took a maximal HHS of 100 to represent an excellent outcome (102 patients. Multiple logistic regression analysis was used to identify independent predictors of excellent outcome. Results The two strongest predictive factors in achieving an excellent result were young age and a high pre-operative HHS (p = 0.001. Conclusions It was the young and those less disabled from their arthritis that excelled at three years. When making a decision about the timing of hip arthroplasty surgery it is important to take into account the age and pre-operative function of the patient. Whether these patients continue to excel however will be the basis of future research.

  12. Determining Health-Related Quality-of-Life Outcomes Using the SF-6D Following Total Hip Arthroplasty.

    Science.gov (United States)

    Elmallah, Randa K; Chughtai, Morad; Adib, Farshad; Bozic, Kevin J; Kurtz, Steven M; Mont, Michael A

    2017-03-15

    Following total hip arthroplasty, patients' perception of their postoperative improvement and health plays a large role in satisfaction with and success of the surgical procedure. The Short Form-6D (SF-6D) is a health-related quality-of-life measure that assigns numerical value to the perception of patients' own health. The purpose was to determine SF-6D values of patients after total hip arthroplasty, to determine whether score changes were clinically relevant, and to compare these with postoperative functional improvements. We evaluated 188 patients who underwent primary total hip arthroplasty at 7 institutions and who had a mean age of 69 years (range, 47 to 88 years) and a mean body mass index of 28.8 kg/m (range, 19.8 to 38.9 kg/m). The SF-6D values were obtained from patients' SF-36 scores, and clinical relevance of value changes was determined using effect size. Using previous research, effect sizes were considered small between 0.2 and 0.5, moderate between 0.6 to 0.8, and large at >0.8. Clinical correlation was assessed using the Lower-Extremity Activity Scale and Harris hip scores. Patients were assessed preoperatively and postoperatively at 6 months and 1, 2, 3, and 5 years. The SF-6D scores improved from preoperatively and achieved significance (p < 0.05) at all points. The effect size demonstrated good clinical relevance up to the latest follow-up: 1.27 at 6 months, 1.30 at 1 year, 1.07 at 2 years, 1.08 at 3 years, and 1.05 at 5 years. The Lower-Extremity Activity Scale improved at all follow-up points from preoperatively to 1.8 at 6 months, 2.0 at 1 year, 1.8 at 2 years, 1.5 at 3 years, and 1.6 points at 5 years. The Harris hip score improved to 38 points at 6 months, 40 points at 1 year, 38 points at 2 years, 39 points at 3 years, and 41 points at 5 years postoperatively. The improvements in the Lower-Extremity Activity Scale and the Harris hip score significantly positively correlated (p < 0.01) with the SF-6D scores at all time points. SF-6D scores

  13. Optimising perioperative care for hip and knee arthroplasty in South Africa: a Delphi consensus study.

    Science.gov (United States)

    Plenge, U; Nortje, M B; Marais, L C; Jordaan, J D; Parker, R; van der Westhuizen, N; van der Merwe, J F; Marais, J; September, W V; Davies, G L; Pretorius, T; Solomon, C; Ryan, P; Torborg, A M; Farina, Z; Smit, R; Cairns, C; Shanahan, H; Sombili, S; Mazibuko, A; Hobbs, H R; Porrill, O S; Timothy, N E; Siebritz, R E; van der Westhuizen, C; Troskie, A J; Blake, C A; Gray, L A; Munting, T W; Steinhaus, H K S; Rowe, P; van der Walt, J G; Isaacs Noordien, R; Theron, A; Biccard, B M

    2018-05-09

    A structured approach to perioperative patient management based on an enhanced recovery pathway protocol facilitates early recovery and reduces morbidity in high income countries. However, in low- and middle-income countries (LMICs), the feasibility of implementing enhanced recovery pathways and its influence on patient outcomes is scarcely investigated. To inform similar practice in LMICs for total hip and knee arthroplasty, it is necessary to identify potential factors for inclusion in such a programme, appropriate for LMICs. Applying a Delphi method, 33 stakeholders (13 arthroplasty surgeons, 12 anaesthetists and 8 physiotherapists) from 10 state hospitals representing 4 South African provinces identified and prioritised i) risk factors associated with poor outcomes, ii) perioperative interventions to improve outcomes and iii) patient and clinical outcomes necessary to benchmark practice for patients scheduled for primary elective unilateral total hip and knee arthroplasty. Thirty of the thirty-three stakeholders completed the 3 months Delphi study. The first round yielded i) 36 suggestions to preoperative risk factors, ii) 14 (preoperative), 18 (intraoperative) and 23 (postoperative) suggestions to best practices for perioperative interventions to improve outcomes and iii) 25 suggestions to important postsurgical outcomes. These items were prioritised by the group in the consecutive rounds and consensus was reached for the top ten priorities for each category. The consensus derived risk factors, perioperative interventions and important outcomes will inform the development of a structured, perioperative multidisciplinary enhanced patient care protocol for total hip and knee arthroplasty. It is anticipated that this study will provide the construct necessary for developing pragmatic enhanced care pathways aimed at improving patient outcomes after arthroplasty in LMICs.

  14. Perioperative transfusion threshold and ambulation after hip revision surgery

    DEFF Research Database (Denmark)

    Nielsen, Kamilla; Johansson, Pär I; Dahl, Benny

    2014-01-01

    BACKGROUND: Transfusion with red blood cells (RBC) may be needed during hip revision surgery but the appropriate haemoglobin concentration (Hb) threshold for transfusion has not been well established. We hypothesized that a higher transfusion threshold would improve ambulation after hip revision...... surgery. METHODS: The trial was registered at Clinicaltrials.gov ( NCT00906295). Sixty-six patients aged 18 years or older undergoing hip revision surgery were randomized to receive RBC at a Hb threshold of either 7.3 g/dL (restrictive group) or 8.9 g/dL (liberal group). Postoperative ambulation...... received RBC. CONCLUSIONS: A Hb transfusion threshold of 8.9 g/dL was associated with a statistically significantly faster TUG after hip revision surgery compared to a threshold of 7.3 g/dL but the clinical importance is questionable and the groups did not differ in Hb at the time of testing....

  15. [Evaluation of the Function and Quality of Life after Total Hip Arthroplasty by Different Approaches].

    Science.gov (United States)

    Araújo, Paulo; Machado, Luís; Cadavez, Duarte; Mónaco, Lisete; Januário, Filipa; Luís, Lisete; Bártolo, Mafalda

    2017-09-29

    To assess the function and quality of life in patients undergoing total hip arthroplasty distinguishing two surgical approaches (posterior / anterolateral) used by the Orthopedics department of Centro Hospitalar de Leiria. Retrospective study of 94 patients subject to unilateral hip replacement surgery, using the 'Hip Osteoarthritis Outcome Score' (HOOS LK 2.0) questionnaire, the Trendelenburg test and evaluation of muscle strength of the hip abductor muscles with dynamometer. Patients were evaluated at six months, 12 months, 18 months and 24 months after surgery. The study revealed that 97.9% patients completed the rehabilitation program. The postoperative evolution (six to 24 months) does not appear to have any differences in results when comparing both approaches. At six months the patient operated by the anterolateral approach showed worse results when compared with the posterior approach, in particular in Hip Osteoarthritis Outcome Score pain, in Hip Osteoarthritis Outcome Score symptoms and Hip Osteoarthritis Outcome Score activities of daily living. After 24 months, no differences between the two surgical approaches were found. Of the 94 patients evaluated, the Trendelenburg test was positive in 31% of patients of which 81.9% corresponds to patients operated by the anterolateral approach. Muscle strength of the abductors of the operated hip was clearly lower in the anterolateral approach at six months, 12 months, and 24 months. This study showed that, in the first six months after total hip arthroplasty, the patients operated by the posterior approach were, according to the HOOS questionnaire, less symptomatic, and presented with better quality of life and less impact on activities of daily living and in sport and leisure when compared with the patients operated by the anterolateral approach. However, these differences were matched over the 24 months. Moreover, the results of muscle strength of the abductor muscles of the hip were clearly superior in

  16. Inflammatory pseudotumor causing deep vein thrombosis after metal-on-metal hip resurfacing arthroplasty.

    LENUS (Irish Health Repository)

    Memon, Adeel Rasool

    2013-01-01

    Metal-on-metal hip resurfacings have recently been associated with a variety of complications resulting from adverse reaction to metal debris. We report a case of extensive soft tissue necrosis associated with a huge pelvic mass causing extensive deep vein thrombosis of the lower limb secondary to mechanical compression of the iliac vein. This is a rare and unusual cause of deep vein thrombosis after metal-on-metal hip resurfacing arthroplasty.

  17. Impaction grafting in the femur in cementless modular revision total hip arthroplasty: a descriptive outcome analysis of 243 cases with the MRP-TITAN revision implant

    Directory of Open Access Journals (Sweden)

    Wimmer Matthias D

    2013-01-01

    Full Text Available Abstract Background We present a descriptive and retrospective analysis of revision total hip arthroplasties (THA using the MRP-TITAN stem (Peter Brehm, Weisendorf, GER with distal diaphyseal fixation and metaphyseal defect augmentation. Our hypothesis was that the metaphyseal defect augmentation (Impaction Bone Grafting improves the stem survival. Methods We retrospectively analyzed the aggregated and anonymized data of 243 femoral stem revisions. 68 patients with 70 implants (28.8% received an allograft augmentation for metaphyseal defects; 165 patients with 173 implants (71.2% did not, and served as controls. The mean follow-up was 4.4 ± 1.8 years (range, 2.1–9.6 years. There were no significant differences (p > 0.05 between the study and control group regarding age, body mass index (BMI, femoral defects (types I-III as described by Paprosky, and preoperative Harris Hip Score (HHS. Postoperative clinical function was evaluated using the HHS. Postoperative radiologic examination evaluated implant stability, axial implant migration, signs of implant loosening, periprosthetic radiolucencies, as well as bone regeneration and resorption. Results There were comparable rates of intraoperative and postoperative complications in the study and control groups (p > 0.05. Clinical function, expressed as the increase in the postoperative HHS over the preoperative score, showed significantly greater improvement in the group with Impaction Bone Grafting (35.6 ± 14.3 vs. 30.8 ± 15.8; p ≤ 0.05. The study group showed better outcome especially for larger defects (types II C and III as described by Paprosky and stem diameters ≥ 17 mm. The two groups did not show significant differences in the rate of aseptic loosening (1.4% vs. 2.9% and the rate of revisions (8.6% vs. 11%. The Kaplan-Meier survival for the MRP-TITAN stem in both groups together was 93.8% after 8.8 years. [Study group 95.7% after 8.54 years ; control group 93

  18. Hydroxyapatite coating does not improve uncemented stem survival after total hip arthroplasty!

    DEFF Research Database (Denmark)

    Hailer, N. P.; Lazarinis, S.; MaKela, K. T.

    2015-01-01

    Background and purpose - It is still being debated whether HA coating of uncemented stems used in total hip arthroplasty (THA) improves implant survival. We therefore investigated different uncemented stem brands, with and without HA coating, regarding early and long-term survival. Patients and m...

  19. Fate of bulk auto grafts in uncemented total hip arthroplasty: Evaluation by bone scintigraphy

    International Nuclear Information System (INIS)

    Simsek, A.; Cila, E.; Sener, E.; Senkoylu, A.; Sipahioglu, S.; Atasever, T.; Akdemir, Ozgur

    2006-01-01

    Objective was to review short term results of uncemented cup implantation and the fate of bulk femoral head autografts in patients with acetabular bone deficiency due to dysplasia of the hip. We used bone scintigraphy to assess the viability of the grafts. We treated 19 hip joints of 17 patients with osteoarthritis due to developmental dysplasia of the hip with uncemented total hip arthroplasty between 1997-2003 in the Department of Orthopedics and Traumatology, Gazi University, Ankara, Turkey. The average age was 49.1 (31-72 years), and the average follow up period was 36 months. We used femoral head autografts to reconstruct superolateral segmental deficiencies of the acetabuli. We evaluated the patients clinically and radiologically to assess acetabular loosening, and we used three-phase bone scintigraphy to evaluate the viability of the autograft.There was no acetabular component revision throughout the follow up period. There was no radiological evidence of graft resorption or graft displacement in any of the patients. In bone scintigraphy, we observed hyperemia in the blood pool phase, and the osteoblastic activity of the bone graft was at the level of the neighboring iliac bone. The application of a non-cemented acetabular component with femoral autograft in superolateral acetabulum deficiency increases the stability of the implant and increases the bone stock. It is not easy to evaluate the viability of the graft by the use of radiological methods. Bone scintigraphy gives sufficient information about the viability of the graft as a non-invasive method. (author)

  20. Hypertrophy of the tensor fascia lata muscle as a complication of total hip arthroplasty.

    Science.gov (United States)

    Rodríguez-Roiz, Juan Miguel; Bori, Guillem; Tomas, Xavier; Fernández-Valencia, Jenaro A; García-Díez, Ana Isabel; Pomés, Jaume; Garcia, Sebastián

    2017-02-01

    Hypertrophy of the tensor fascia lata muscle (HTFLM) is a rare complication after total hip arthroplasty (THA) and is a potential source of pain, palpable mass, or both. We retrospectively analyzed 1285 primary THAs and 482 THA revisions (THAR) performed at our center from 2008 to 2014. Among these, five patients had HTFLM (average age 68.8 years). The type of surgery and symptoms were evaluated, as were imaging studies (CT or MRI) of both hips (10 hips), and functional outcomes with the Merle d'Aubigné score. The suspected diagnosis was established at an average of 30.2 months after surgery. Four cases occurred after THA and one case after THAR. A modified Hardinge approach was used in four cases and a Röttinger approach in one case. Two cases had pain and palpable mass in the trochanteric region and three cases only pain. The asymmetric HTFLM of the THA side against the nonsurgical side was confirmed by measuring the cross section of the tensor fascia lata muscle on imaging. The sartorius muscle was measured for reference in each case. The Merle d'Aubigne scale had a mean value of 16.6 (range 13-18) at 38 months after the procedure. HTFLM after THA is a benign condition that could be mistaken for a tumor when presenting as a palpable mass. We propose that it should be considered in the differential diagnosis of pain in the lateral aspect of hips that have previously undergone THA.

  1. Can Arthroplasty Stem INfluence Outcome? (CASINO): a randomized controlled equivalence trial of 125 mm versus 150 mm Exeter V40 stems in total hip arthroplasty.

    Science.gov (United States)

    Hamilton, David F; Ohly, Nicholas E; Gaston, Paul

    2018-04-16

    The use of shorter length femoral stems during total hip arthroplasty has been suggested to accommodate wider patient femoral geometry and offer maximal bone preservation. However, cemented short-stem designs may increase the risk of varus stem malalignment and influence patient outcomes. CASINO is a multi-centre randomised equivalence trial that will recruit 220 patients undergoing total hip arthroplasty for osteoarthritis at two NHS hospitals in Scotland. Patients will be aged 45-80, undergoing unilateral primary hip arthroplasty, with no plan for contralateral procedure within the study timeframe, and able to comply with the protocol. Participants will be randomised to receive either a short (125 mm) or a standard (150 mm) Exeter V40 stem. The Contemporary acetabular component will be used in all cases. All implants will be cemented. Patient pain, function and satisfaction will be assessed using change from baseline measurement in Oxford Hip Score, Forgotten Joint Score, EQ-5D, pain numerical rating scores, and patient satisfaction questionnaire at baseline and at 1 and 2 years following surgery. Radiographic assessment will evaluate stem position and will be appraised by independent reviewers. Patients will be blind to implant allocation. Stem length may be associated with outcome; however, we can find no randomised trial in which researchers investigated the effect of stem length on patient outcome following cemented total hip arthroplasty. The aim of this trial is to determine if the use of short cemented stems offers equivalent patient outcomes to those achieved following surgery with standard length stems. International Standard Randomised Controlled Trial Number, ISRCTN13154542 , Registered on 30 June 2017.

  2. Postoperative Morbidity and Discharge Destinations After Fast-Track Hip and Knee Arthroplasty in Patients Older Than 85 Years

    DEFF Research Database (Denmark)

    Pitter, Frederik T; Jørgensen, Christoffer C; Lindberg-Larsen, Martin

    2016-01-01

    BACKGROUND: Elderly patients are at risk of increased length of hospital stay (LOS), postoperative complications, readmission, and discharge to destinations other than home after elective total hip arthroplasty (THA) and total knee arthroplasty (TKA). Recent studies have found that enhanced...

  3. Chromium and cobalt ion concentrations in blood and serum following various types of metal-on-metal hip arthroplasties

    DEFF Research Database (Denmark)

    Jantzen, Christopher; Jørgensen, Henrik L; Duus, Benn R

    2013-01-01

    Widely different metal ion concentrations in blood and serum have been reported with metal-on-metal (MoM) implants. We reviewed the literature on blood and serum ion concentrations of chromium (Cr) and cobalt (Co) following various MoM hip arthroplasties.......Widely different metal ion concentrations in blood and serum have been reported with metal-on-metal (MoM) implants. We reviewed the literature on blood and serum ion concentrations of chromium (Cr) and cobalt (Co) following various MoM hip arthroplasties....

  4. Radiographic cup position following posterior and lateral approach to total hip arthroplasty. An explorative randomized controlled trial.

    Science.gov (United States)

    Kruse, Christine; Rosenlund, Signe; Broeng, Leif; Overgaard, Søren

    2018-01-01

    The two most common surgical approaches to total hip arthroplasty are the posterior approach and lateral approach. The surgical approach may influence cup positioning and restoration of the offset, which may affect the biomechanical properties of the hip joint. The primary aim was to compare cup position between posterior approach and lateral approach. Secondary aims were to compare femoral offset, abductor moment arm and leg length discrepancy between the two approaches. Eighty patients with primary hip osteoarthritis were included in a randomized controlled trial and assigned to total hip arthroplasty using posterior approach or lateral approach. Postoperative radiographs from 38 patients in each group were included in this study for measurement of cup anteversion and inclination. Femoral offset, cup offset, total offset, abductor moment arm and leg length discrepancy were measured on preoperative and postoperative radiographs in 28 patients in each group. We found that mean anteversion was 5° larger in the posterior approach group (95% CI, -8.1 to -1.4; p = 0.006), while mean inclination was 5° less steep (95% CI, 2.7 to 7.2; pcup anteversion but less steep cup inclination in the posterior approach group compared with the lateral approach group. Femoral offset and abductor moment arm were restored after total hip arthroplasty using lateral approach but significantly increased when using posterior approach.

  5. CCD and offset after Nanos short stem in total hip arthroplasty.

    Science.gov (United States)

    Ettinger, M; Ettinger, P; Ezechieli, M; Büermann, S; Budde, S; Calließ, T; Petri, M; Thorey, F

    2013-01-01

    Many short stems for total hip arthroplasty have been introduced by the manufacturers only during the last decade. One of them is the Nanos short stem (Smith and Nephew, Marl, Germany). The development of short stems was aimed at preserving bone and soft tissue by utilizing a minimally invasive approach, thus allowing a quick return to an active life. It was purpose of this study to evaluate the radiological changes after using this device. We present the radiological results of 202 cementless THAs which were performed in 172 patients using the Nanos stem. Radiological evaluation was performed using standing anterior-posterior (AP) and lateral radiographs of the proximal femur preoperatively, postoperatively and during the follow up. We analyzed the preoperative and postoperativ CCD angle, the subsisdence, preoperative and postoperative offset, osteolysis, bone resorption, increased density, neocortex and periarthricular ossifications. One stem had to be revised due to subsidence four days after implantation. Two cups (BiconPlus, Smith and Nephew, Marl, Germany) had to be revised during the time of follow up due to an aseptic cup loosening. Two stems showed radiolucent lines at the implant-bone-interface at the last follow-up. An increase of bone density could be detected in 18 hips (8.9%). 14 hips showed periarticular ossifications. Measurable subsidence was detected in a total of four stems (1.9%). The preoperative neck-shaft-angle angle was 133.8 ± 4.4° (range: 118.5-146.2) and the neck-shaft-angle angle at the time of follow up was 134.6 ± 4.3° (range: 123.3-147; P< 0.05). The preoperative and postoperative offset changed from 109.3 ± 11.9 mm (range: 80.9-131.6) to 109.7 ± 12.3 mm (range: 79.7-155.6; P< 0.05). In summary, this study shows that a correct anatomical reconstruction is possible with a device of this design. The outcome is comparable to that of other short stems. Further studies should be performed in a prospective and randomized design to

  6. Botulinum toxin type A injections for the management of muscle tightness following total hip arthroplasty: a case series

    Directory of Open Access Journals (Sweden)

    Delanois Ronald E

    2009-08-01

    Full Text Available Abstract Background Development of hip adductor, tensor fascia lata, and rectus femoris muscle contractures following total hip arthroplasties are quite common, with some patients failing to improve despite treatment with a variety of non-operative modalities. The purpose of the present study was to describe the use of and patient outcomes of botulinum toxin injections as an adjunctive treatment for muscle tightness following total hip arthroplasty. Methods Ten patients (14 hips who had hip adductor, abductor, and/or flexor muscle contractures following total arthroplasty and had been refractory to physical therapeutic efforts were treated with injection of botulinum toxin A. Eight limbs received injections into the adductor muscle, 8 limbs received injections into the tensor fascia lata muscle, and 2 limbs received injection into the rectus femoris muscle, followed by intensive physical therapy for 6 weeks. Results At a mean final follow-up of 20 months, all 14 hips had increased range in the affected arc of motion, with a mean improvement of 23 degrees (range, 10 to 45 degrees. Additionally all hips had an improvement in hip scores, with a significant increase in mean score from 74 points (range, 57 to 91 points prior to injection to a mean of 96 points (range, 93 to 98 at final follow-up. There were no serious treatment-related adverse events. Conclusion Botulinum toxin A injections combined with intensive physical therapy may be considered as a potential treatment modality, especially in difficult cases of muscle tightness that are refractory to standard therapy.

  7. Refractory pain following hip arthroscopy: evaluation and management

    Science.gov (United States)

    de SA, Darren L; Burnham, Jeremy M; Mauro, Craig S

    2018-01-01

    ABSTRACT With increased knowledge and understanding of hip pathology, hip arthroscopy is rapidly becoming a popular treatment option for young patients with hip pain. Despite improved clinical and radiographic outcomes with arthroscopic treatment, some patients may have ongoing pain and less than satisfactory outcomes. While the reasons leading to failed hip arthroscopy are multifactorial, patient selection, surgical technique and rehabilitation all play a role. Patients with failed hip arthroscopy should undergo a thorough history and physical examination, as well as indicated imaging. A treatment plan should then be developed based on pertinent findings from the workup and in conjunction with the patient. Depending on the etiology of failed hip arthroscopy, management may be nonsurgical or surgical, which may include revision arthroscopic or open surgery, periacetabular osteotomy or joint arthroplasty. Revision surgery may be appropriate in settings including, but not limited to, incompletely treated femoroacetabular impingement, postoperative adhesions, heterotopic ossification, instability, hip dysplasia or advanced degeneration. PMID:29423245

  8. Implant survival of the most common cemented total hip devices from the Nordic Arthroplasty Register Association database

    DEFF Research Database (Denmark)

    Junnila, Mika; Laaksonen, Inari; Eskelinen, Antti

    2016-01-01

    Background and purpose - According to previous Nordic Arthroplasty Register Association (NARA) data, the 10-year implant survival of cemented total hip arthroplasties (THAs) is 94% in patients aged 65-74 and 96% in patients aged 75 or more. Here we report a brand-level comparison of cemented THA...

  9. Nursing in fast-track total hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Specht, Kirsten; Kjaersgaard-Andersen, Per; Kehlet, Henrik

    2015-01-01

    must still focus on the individual patient. Nurses need to have enough education to manage the complex tasks and increased responsibility. To prevent undesirable outcomes in the future, there is a need to pay attention to the nursing quality in balance with the nursing budget. It may, therefore......AIM: To describe the increased activity in total hip arthroplasty (THA) and total knee arthroplasty (TKA) from 2002 to 2012 in a single orthopaedic department, the organisation of fast-track and its consequences for nursing care. METHODS: Retrospective, descriptive design. Data collection; from...... gained tasks from surgeons and physiotherapists and thus gained more responsibility, for example, for pain management and mobilisation. Staffing levels in the ward in 2002 and 2012 were almost unchanged; 16.0 and 15.8 respectively. Nurses were undertaking more complicated tasks. CONCLUSION: Nursing care...

  10. Do Independent Sector Treatment Centres (ISTC) impact on specialist registrar training in primary hip and knee arthroplasty?

    Science.gov (United States)

    Clamp, Jonathan A; Baiju, Dean; Copas, David P; Hutchinson, James W; Rowles, John M

    2008-09-01

    The introduction of Modernising Medical Careers (MMC) is likely to reduce specialist registrar (SpR) operative experience during higher surgical training (HST). A further negative impact on training by local Independent Sector Treatment Centres (ISTCs) could reduce experience, and thus competence, in primary joint arthroplasty at completion of higher surgical training. Retrospective case note and radiograph analysis of patients receiving primary hip and knee arthroplasty in a teaching hospital, before and after the establishment of a local ISTC. Patients and operative details were recorded from the selected case notes. Corresponding radiographs were assessed and the severity of the disease process assessed. Fewer primary hip and knee replacements were performed by SpRs in the time period after the establishment of an ISTC. ISTCs may adversely affect SpR training in primary joint arthroplasty.

  11. Revision of failed hemiarthroplasty for painful glenoid arthrosis to anatomic total shoulder arthroplasty.

    Science.gov (United States)

    Sheth, Mihir M; Sholder, Daniel; Abboud, Joseph; Lazarus, Mark D; Ramsey, Matthew L; Williams, Gerald R; Namdari, Surena

    2018-05-10

    The impending burden of revision shoulder arthroplasty has increased interest in outcomes of revision procedures. Painful glenoid arthrosis following hemiarthroplasty is a common cause of reoperation, and conversion to anatomic total shoulder arthroplasty is one option. We identified patients who underwent revision of painful hemiarthroplasty to total shoulder arthroplasty over a 15-year period in a single tertiary-care health system. Presurgical and operative data were analyzed for 28 patients who met the inclusion and exclusion criteria. Patients were contacted at a minimum of 2 years' follow-up after revision surgery for functional outcome scores, reoperations, and implant survival. The 2- and 5-year implant survival rates were 93% and 86%, respectively. Functional outcomes were obtained from 21 patients with surviving implants. The mean American Shoulder and Elbow Surgeons score, visual analog scale score for pain, and Single Assessment Numerical Evaluation score were 78 ± 20, 2.3 ± 2.6, and 71 ± 24, respectively. The mean Short Form 12 mental and physical scores were 49 ± 10 and 43 ± 9, respectively. Of the patients, 17 (81%) were either satisfied or very satisfied with their outcome. Complications were seen in 10 patients (36%), and 6 patients (21%) required reoperation. Anatomic total shoulder arthroplasty following hemiarthroplasty can achieve successful outcomes and implant survival rates. Given our poor understanding of reverse shoulder arthroplasty longevity, this procedure should remain an option for patients with glenoid arthrosis and an intact rotator cuff. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  12. Primary total hip replacement versus hip resurfacing - hospital considerations.

    Science.gov (United States)

    Ward, William G; Carter, Christina J; Barone, Marisa; Jinnah, Riyaz

    2011-01-01

    Multiple factors regarding surgical procedures and patient selection affect hospital staffing needs as well as hospital revenues. In order to better understand the potential impact on hospitals that hip arthroplasty device selection (standard total hip arthroplasty vs. resurfacing) creates, a review of all primary hip arthroplasties performed at one institution was designed to identify factors that impacted hospital staffing needs and revenue generation. All primary hip arthroplasties undertaken over three fiscal years (2008 to 2010) were reviewed, utilizing only hospital business office data and medical records data that had been previously extracted prior for billing purposes. Analysis confirmed differing demographics for two hip arthroplasty populations, with the resurfacing patients (compared to the conventional total hip arthroplasty population) consisting of younger patients (mean age, 50 vs. 61 years), who were more often male (75% vs. 45%), were more likely to have osteoarthritis as their primary diagnosis (83 vs. 67%) and were more often covered by managed care or commercial insurance (83 vs. 34%). They also had shorter hospital stays (mean length of stay, 2.3 vs. 4.1 days) and consequently provided a more favorable financial revenue stream to the hospital on a per patient basis. Several trends appeared during the study periods. There was a steady increase in all procedures in all groups except for the resurfacings, which decreased 26% in males and 53% in females between 2009 and 2010. Differences were observed in the demographics of patients presenting for resurfacing, compared to those presenting for conventional total hip arthroplasty. In addition to the revenue stream considerations, institutions undertaking a resurfacing program must commit the resources and planning in order to rehabilitate these patients more expeditiously than is usually required with conventional hip arthroplasty patients.

  13. Dual X-ray absortiometry(DXA) in the detection of loosening in the total hip replacement arthroplasty: preliminary study

    International Nuclear Information System (INIS)

    Yoon, Hye Kyung; Kang, Heung Sik; Han, Man Chung; Kim, Hee Joong; Kim, Young Min

    1994-01-01

    Algorithms to get cross-sectional bone density pattern(transverse histogram) to predict the loosening of hip prosthesis using DXA(Dual X-ray Absorptiometry) have been developed. We performed this study to analyze the correlation between radiologic findings and densitometric pattern of the THRA(Total Hip Replacement Arthroplasty) patients. Thirty-six hips of 32 THRA patients were evaluated. The duration between THRA and DXA was from 1 year 7 months to 15 years. On transverse histogram, the periprosthetic bone density patterns were classified as 3 types; type I , rigid fixation in 17, type II definite loosening in 8, and type III, partial loosening in 11 cases. Surgical findings, plain X-ray findings and transverse histogram using DXA were correlated. Among 14 cases performing revision for acetabular prosthesis loosening, 5 cases revealed loosening of femoral stems while 9 cases revealed rigid fixation of femoral stems. Sensitivity was 100% for either plain X-ray or DXA. Specificity was 88%, 77% for plain X-ray and DXA respectively. This preliminary study reveals that periprosthetic bone density pattern on transverse histogram on DXA may be useful in the evaluation of the loosening. However, further study will be needed for clinical application

  14. Psychopharmacologic treatment and blood transfusion in fast-track total hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Gylvin, Silas Hinsch; Jørgensen, Christoffer Calov; Fink-Jensen, Anders

    2017-01-01

    BACKGROUND: Selective serotonin reuptake inhibitors (SSRIs) and other psychotropics are receiving increasing attention due to reports on inhibition of thrombocyte function and an increased bleeding risk in surgical settings. Studies in total hip and total knee arthroplasty (THA and TKA...

  15. What Is the Impact of Smoking on Revision Total Knee Arthroplasty?

    Science.gov (United States)

    Bedard, Nicholas A; Dowdle, S Blake; Wilkinson, Brandon G; Duchman, Kyle R; Gao, Yubo; Callaghan, John J

    2018-07-01

    There is a paucity of literature evaluating the impact of smoking on revision arthroplasty procedures. The purpose of this study was to identify the effect of smoking on complications after revision total knee arthroplasty (rTKA). We queried the American College of Surgeons National Surgical Quality Improvement Program (NSQIP) database to identify patients who underwent rTKA between 2006 and 2014. Patients were divided into current smokers and nonsmokers according to the NSQIP definitions. Each cohort was compared in terms of demographic data, preoperative comorbidities, and operative time. Infection end points were created from composite surgical site infection variables defined by the NSQIP database. Multivariate logistic regression analysis was utilized to adjust for confounding variables and calculate adjusted odds ratios (ORs) and associated 95% confidence intervals (95% CIs). In total, 8776 patients underwent rTKA. Of these patients, 11.6% were current smokers. Univariate analyses demonstrated that smokers had a higher rate of any wound complication (3.8% vs 1.8%, P < .0001), deep infection (2.5% vs 1.0%, P < .0001), pneumonia (1.3% vs 0.4%, P < .0001), and reoperation (5.0% vs 3.1%, P = .001) compared to nonsmokers undergoing revision total knee arthroplasty. Multivariate analysis identified current smokers as being at a significantly increased risk of any wound complication (OR 2.1; 95% CI 1.4-3.1) and deep infection (OR 2.1, 95% CI 1.2-3.6) after rTKA. This study demonstrates that smoking significantly increases the risk of infection, wound complications, and reoperation after rTKA. The results are even more magnified for revision procedures compared to published effects of smoking on primary total knee arthroplasty complications. Further research is needed regarding the impact of smoking cessation on mitigation of these observed risks. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Unusual presentation of failed metal-on-metal total hip arthroplasty with features of neoplastic process

    Directory of Open Access Journals (Sweden)

    Robert P. Runner, MD

    2017-06-01

    Full Text Available Metal-on-metal (MoM total hip arthroplasty (THA is associated with increased incidence of failure from metallosis, adverse tissue reactions, and the formation of pseudotumors. This case highlights a 53-year-old female with an enlarging painful thigh mass 12 years status post MoM THA. Radiographs and advanced imaging revealed an atypical mass with cortical bone destruction and spiculation, concerning for periprosthetic malignancy. Open frozen section biopsy was performed before undergoing revision THA in a single episode of care. This case illustrates that massive pseudotumors can be locally aggressive causing significant femoral bone destruction and may mimic malignancy. It is important that orthopaedic surgeons, radiologists and pathologists understand the relative infrequency of periprosthetic malignancy in MoM THA to mitigate patient concerns, misdiagnosis, and allow for an evidence based discussion when treating massive pseudotumors.

  17. Tribology of total hip arthroplasty prostheses

    Science.gov (United States)

    Rieker, Claude B.

    2016-01-01

    Articulating components should minimise the generation of wear particles in order to optimize long-term survival of the prosthesis. A good understanding of tribological properties helps the orthopaedic surgeon to choose the most suitable bearing for each individual patient. Conventional and highly cross-linked polyethylene articulating either with metal or ceramic, ceramic-on-ceramic and metal-on-metal are the most commonly used bearing combinations. All combinations of bearing surface have their advantages and disadvantages. An appraisal of the individual patient’s objectives should be part of the assessment of the best bearing surface. Cite this article: Rieker CB. Tribology of total hip arthroplasty prostheses: what an orthopaedic surgeon should know. EFORT Open Rev 2016;1:52-57. DOI: 10.1302/2058-5241.1.000004. PMID:28461928

  18. Outcome of total hip arthroplasty for avascular necrosis of the femoral head in systemic lupus erythematosus.

    Science.gov (United States)

    Woo, Min Su; Kang, Joon Soon; Moon, Kyoung Ho

    2014-12-01

    This study evaluated the result of total hip arthroplasty (THA) for avascular necrosis of the femur head (AVNFH) in systemic lupus erythematosus (SLE) patients. Nineteen THAs were performed on 13 patients with SLE. The results of these patients were compared with the results of the control group (19 patients) who had THR due to AVNFH with none-SLE conditions. The Harris hip score increased from a preoperative average of 65.3 points to 94.9 at the most recent follow-up. In the control group, the mean HHS was 67.2 preoperatively and 96.1 postoperatively at the last follow-up. No significant difference was found between SLE patients and non-SLE patients who underwent hip arthroplasty. In conclusion, THA is an acceptable treatment for achieving functional improvement in patients who had SLE and AVNFH. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. The unsuspected prosthetic joint infection : incidence and consequences of positive intra-operative cultures in presumed aseptic knee and hip revisions.

    Science.gov (United States)

    Jacobs, A M E; Bénard, M; Meis, J F; van Hellemondt, G; Goosen, J H M

    2017-11-01

    Positive cultures are not uncommon in cases of revision total knee and hip arthroplasty (TKA and THA) for presumed aseptic causes. The purpose of this study was to assess the incidence of positive intra-operative cultures in presumed aseptic revision of TKA and THA, and to determine whether the presence of intra-operative positive cultures results in inferior survival in such cases. A retrospective cohort study was assembled with 679 patients undergoing revision knee (340 cases) or hip arthroplasty (339 cases) for presumed aseptic causes. For all patients three or more separate intra-operative cultures were obtained. Patients were diagnosed with a previously unsuspected prosthetic joint infection (PJI) if two or more cultures were positive with the same organism. Records were reviewed for demographic details, pre-operative laboratory results and culture results. The primary outcome measure was infection-free implant survival at two years. The incidence of unsuspected PJI was 27 out of 340 (7.9%) in TKA and 41 out of 339 (12.1%) in THA. Following revision TKA, the rate of infection-free implant survival in patients with an unsuspected PJI was 88% (95% confidence intervals (CI) 60 to 97) at two years compared with 98% (95% CI 94 to 99) in patients without PJI (p = 0.001). After THA, the rate of survival was similar in those with unsuspected PJI (92% (95% CI 73 to 98) at two years) and those without (94% (95% CI 89 to 97), p = 0.31). Following revision of TKA and THA for aseptic diagnoses, around 10% of cases were found to have positive cultures. In the knee, such cases had inferior infection-free survival at two years compared with those with negative cultures; there was no difference between the groups following THA. Cite this article: Bone Joint J 2017;99-B:1482-9. ©2017 The British Editorial Society of Bone & Joint Surgery.

  20. TOTAL HIP ARTHROPLASTY IN OSTEOPETROSIS – REPORT OF A CASE

    Directory of Open Access Journals (Sweden)

    Zmago Krajnc

    2004-04-01

    Full Text Available Background. Authors introduced a case of a 27-year men with osteopetrosis with hip arthrosis. He has an autosomal – dominant form of disease and he needed total hip arthroplasty. There are seven cases described in literature with developed hip arthrosis by osteopetrosis.Methods. TEP implantation represents the greates surgical challenge in this patients, especially creation of intramedullary canal in femur and implantation of the femoral stem because of the very dense and brittle bones. This article describes the operative technique used in the case involved. It proved to be a very good solution.Results. The patient was released from the hospital ten days after implantation of total hip endoprosthesis. Three months after the operation the patient started to walk without aid of canes, he had non pain, and his range of motion was almost normal.Conclusions. Severe coxarthrosis is a rare complication of osteopetrosis. Great care must be taken with implantation of total hip endoprosthesis, especially with preparation of medular canal. It was recommended hand drilling under x-rays to exercise maximal control because reaming can cause false root of stem and greater probability of fracture.

  1. Total joint arthroplasty in nonagenarians--a retrospective review of complications and resource use.

    LENUS (Irish Health Repository)

    Baker, Joseph F

    2012-12-01

    Increased age brings with it the potential for increased surgical risk. Assessment of specific age cohorts is necessary to plan future service provision and this is the case in hip and knee arthroplasty as the demand for these procedures is anticipated to increase. We retrospectively reviewed the outcomes, including complications, length of stay and blood transfusion rate, in a cohort of 35 nonagenarians undergoing primary or revision total hip and knee arthroplasty. All patients were pre-assessed by anaesthetists before being deemed suitable to undergo surgery in the unit. The mean length of hospital stay was 13.7 +\\/- 10 days (range 2-56). Thirty-one percent of patients required a blood transfusion. Patients who underwent primary total hip arthroplasty reported improved joint specific functional scores. In this appropriately selected group of nonagenarians, we found no evidence to suggest surgery be withheld on the basis of age alone. However, patients with multiple medical comorbidities warrant appropriate assessment and surgical intervention in an institution with appropriate support. Future planning needs to take into account the predicted increase in demand for arthroplasty surgery in this age group.

  2. The possibilities of magnetic resonance imaging in the diagnostics of complications after metal-on-metal hip arthroplasty

    Directory of Open Access Journals (Sweden)

    A. A. Vergay

    2013-01-01

    Full Text Available Objective: to find adverse periprosthetic local tissue reactions after metal-on-metal hip arthroplasty with ASR XL heads. Material and methods: 119 patients with 134 ASR XL head - Corail prostheses were treated in 2007-2009. The results were studied in 94 cases (105 prostheses - 84%. Average follow-up time consisted 62 ± 3 months. MRI was performed in 12 patients (13 hips who had clinical nonsatisfaction. Obtained data were compared with 21 MRI (24 hips of controlled group with good and perfect clinical results. Results. We found variations of normal periprosthetic tissue condition. Adverse reactions were identified in 10 cases. To improve the quality of pictures we developed special MRI adjustments and regimes of work. Conclusion: MRI diagnostics is indicated for the patients with metal-on-metal total hip arthroplasty in order to identify adverse local tissue reactions. The improvement of picture quality needs special adjustment of MRI equipment.

  3. Total-hip arthroplasty: Periprosthetic indium-111-labeled leukocyte activity and complementary technetium-99m-sulfur colloid imaging in suspected infection

    International Nuclear Information System (INIS)

    Palestro, C.J.; Kim, C.K.; Swyer, A.J.; Capozzi, J.D.; Solomon, R.W.; Goldsmith, S.J.

    1990-01-01

    Indium-111-labeled leukocyte images of 92 cemented total-hip arthroplasties were correlated with final diagnoses. Prostheses were divided into four zones: head (including acetabulum), trochanter, shaft, and tip. The presence (or absence) and intensity of activity in each zone was noted, and compared to the corresponding contralateral zone. Though present in all 23 infected arthroplasties, periprosthetic activity was also present in 77% of uninfected arthroplasties, and was greater than the contralateral zone 51% of the time. When analyzed by zone, head zone activity was the best criterion for infection (87% sensitivity, 94% specificity, 92% accuracy). Fifty of the arthroplasties were studied with combined labeled leukocyte/sulfur colloid imaging. Using incongruence of images as the criterion for infection, the sensitivity, specificity, and accuracy of the study were 100%, 97%, and 98%, respectively. While variable periprosthetic activity makes labeled leukocyte imaging alone unreliable for diagnosing hip arthroplasty infection, the addition of sulfur colloid imaging results in a highly accurate diagnostic procedure

  4. Do large heads enhance stability and restore native anatomy in primary total hip arthroplasty?

    Science.gov (United States)

    Lombardi, Adolph V; Skeels, Michael D; Berend, Keith R; Adams, Joanne B; Franchi, Orlando J

    2011-06-01

    Dislocation remains a serious complication in hip arthroplasty. Resurfacing proponents tout anatomic femoral head restoration as an advantage over total hip arthroplasty. However, advances in bearings have expanded prosthetic head options from traditional sizes of 22, 26, 28, and 32 mm to diameters as large as 60 mm. Large heads reportedly enhance stability owing to increased range of motion before impingement and increased jump distance to subluxation. Available larger diameter material combinations include metal- or ceramic-on-highly crosslinked polyethylene and metal-on-metal, each with distinct advantages and disadvantages. We sought to determine (1) if using larger diameter heads has lowered our dislocation rate; and (2) how closely an anatomic metal-on-metal bearing with diameters to 60 mm replicates native femoral head size. We retrospectively reviewed 2020 primary arthroplasties performed with large heads (≥ 36 mm) in 1748 patients and noted dislocation incidence. In a prospective subset of 89 cases using anatomic heads, native femoral head diameter was measured intraoperatively with calipers by an independent observer and later compared with implanted size. One dislocation has occurred in 2020 hips for an incidence of 0.05%. The prosthetic head averaged 0.7 mm larger than the native head with 68 of 89 (76%) reconstructed to within ± 2 mm of native size. Larger diameter heads have contributed to lower dislocation rates and large-diameter metal-on-metal articulation can provide close anatomic restoration in primary THA.

  5. Medium-term outcome in patients treated with total hip arthroplasty using a modular femoral stem.

    Science.gov (United States)

    Dagnino, Augusto; Grappiolo, Guido; Benazzo, Franco M; Learmonth, Ian D; Spotorno, Lorenzo; Portinaro, Nicola

    2012-01-01

    The clinical, radiographic and quality of life results of total hip arthroplasty using the MODULUS cementless modular femoral stem were reviewed. 48 patients who had a total hip arthroplasty using the MODULUS femoral stem were identified. Six had bilateral procedures, resulting in 60 hips with complete clinical and radiographic data. Mean age at implantation was 50 years (range 33 to 82). Mean follow-up was 59 months (range 50 months to 73). There were two early post-operative dislocations (within 2 days). One patient required further surgery to remove heterotopic bone. Mean Harris Hip Score increased from 37 points preoperatively (range, 7 to 66) to 89 points at final review (range, 65 to 100 points). Radiographic evaluation revealed that all implants were stable without evidence of osteolysis but three patients (5%) exhibited heterotopic ossification. Quality of life was evaluated with the SF36. The physical component increased from 29.2 points (range, 18.5 to 46.0) to 51.7 points (range 42.9 to 60.6) and the mental component from 375 points (range, 19.5 to 50.0) to 50 points (range 32,8 to 62.0).

  6. There Is a Significant Discrepancy Between "Big Data" Database and Original Research Publications on Hip Arthroscopy Outcomes: A Systematic Review.

    Science.gov (United States)

    Sochacki, Kyle R; Jack, Robert A; Safran, Marc R; Nho, Shane J; Harris, Joshua D

    2018-06-01

    The purpose of this study was to compare (1) major complication, (2) revision, and (3) conversion to arthroplasty rates following hip arthroscopy between database studies and original research peer-reviewed publications. A systematic review was performed using PRISMA guidelines. PubMed, SCOPUS, SportDiscus, and Cochrane Central Register of Controlled Trials were searched for studies that investigated major complication (dislocation, femoral neck fracture, avascular necrosis, fluid extravasation, septic arthritis, death), revision, and hip arthroplasty conversion rates following hip arthroscopy. Major complication, revision, and conversion to hip arthroplasty rates were compared between original research (single- or multicenter therapeutic studies) and database (insurance database using ICD-9/10 and/or current procedural terminology coding terminology) publishing studies. Two hundred seven studies (201 original research publications [15,780 subjects; 54% female] and 6 database studies [20,825 subjects; 60% female]) were analyzed (mean age, 38.2 ± 11.6 years old; mean follow-up, 2.7 ± 2.9 years). The database studies had a significantly higher age (40.6 + 2.8 vs 35.4 ± 11.6), body mass index (27.4 ± 5.6 vs 24.9 ± 3.1), percentage of females (60.1% vs 53.8%), and longer follow-up (3.1 ± 1.6 vs 2.7 ± 3.0) compared with original research (P database studies (P = .029; relative risk [RR], 1.3). There was a significantly higher rate of femoral neck fracture (0.24% vs 0.03%; P database studies. Reoperations occurred at a significantly higher rate in the database studies (11.1% vs 7.3%; P database studies (8.0% vs 3.7%; P Database studies report significantly increased major complication, revision, and conversion to hip arthroplasty rates compared with original research investigations of hip arthroscopy outcomes. Level IV, systematic review of Level I-IV studies. Copyright © 2018 Arthroscopy Association of North America. Published by Elsevier Inc. All rights

  7. Quantifying gait quality in patients with large-head and conventional total hip arthroplasty

    DEFF Research Database (Denmark)

    Jensen, Carsten; Penny, Jeannette Østergaard; Nielsen, Dennis Brandborg

    2015-01-01

    We used the Gait Deviation Index (GDI) as method to compare preoperative to postoperative gait changes after uncemented 50mm(median) large-head and 28/32mmtotal hip arthroplasty (THA). We also identified predictors of improvements in GDI. Gait analysis and patient-reported (WOMAC) datawere record...

  8. The Morse taper junction in modular revision hip replacement--a biomechanical and retrieval analysis.

    Science.gov (United States)

    Schramm, M; Wirtz, D C; Holzwarth, U; Pitto, R P

    2000-04-01

    All biomaterials used for total joint surgery are subjected to wear mechanisms. Morse taper junctions of modular hip revision implants are predilection sites for both fretting and crevice corrosion, dissociation and breakage of the components. The aim of this study is to quantify wear and study metallurgical changes of Morse taper junctions of in-vitro and in-vivo loaded modular revision stems. Three modular revision stems (MRP-Titan, Peter Brehm GmbH, Germany) were loaded by a servohydraulic testing machine. The loads and conditions used exceeded by far the values required by ISO-standard 7206. The tests were performed with maximum axial loads of 3,500 N to 4,000 N over 10-12 x 10(6) cycles at 2 Hz. Additionally, the female part of the taper junctions were coated with blood and bone debris. The free length of the implant was set to 200 mm. One other MRP stem was investigated after retrieval following 5.5 years of in-vivo use. All contact surfaces of the modular elements were assessed by visual inspection, optical microscopy and scanning electron microscopy (SEM). The degree of plastic deformation of the male part of the morse taper junction was determined by contouroscopy. None of the morse taper junctions broke or failed mechanically. Corrosion and wear affected all tapers, especially at the medial side. The retrieved implant showed no cracks and the amount of debris measured only one third of that for the stems tested in-vitro. The present retrieval and laboratory investigations have proven, that the morse taper junctions of the MRP-titanium stem are stable and resistant to relevant wear mechanisms. The longevity of the junctions for clinical use is given. If an optimal taper design is selected, the advantages of modular femoral components in total hip revision arthroplasty will outweigh the possible risks.

  9. Total Hip Arthroplasty – over 100 years of operative history

    Directory of Open Access Journals (Sweden)

    Stephen Richard Knight

    2011-11-01

    Full Text Available Total hip arthroplasty (THA has completely revolutionised the nature in which the arthritic hip is treated, and is considered to be one of the most successful orthopaedic interventions of its generation (1. With over 100 years of operative history, this review examines the progression of the operation from its origins, together with highlighting the materials and techniques that have contributed to its development. Knowledge of its history contributes to a greater understanding of THA, such as the reasons behind selection of prosthetic materials in certain patient groups, while demonstrating the importance of critically analyzing research to continually determine best operative practice. Finally, we describe current areas of research being undertaken to further advance techniques and improve outcomes.

  10. Comparing return to sport activities after short metaphyseal femoral arthroplasty with resurfacing and big femoral head arthroplasties.

    Science.gov (United States)

    Karampinas, Panagiotis K; Papadelis, Eustratios G; Vlamis, John A; Basiliadis, Hlias; Pneumaticos, Spiros G

    2017-07-01

    Young patients feel that maintaining sport activities after total hip arthroplasty constitutes an important part of their quality of life. The majority of hip surgeons allow patients to return to low-impact activities, but significant caution is advised to taking part in high-impact activities. The purpose of this study is to compare and evaluate the post-operative return to daily living habits and sport activities following short-metaphyseal hip and high functional total hip arthroplasties (resurfacing and big femoral head arthroplasties). In a study design, 48 patients (55 hips) were enrolled in three different comparative groups, one with the short-metaphyseal arthroplasties, a second with high functional resurfacing arthroplasties and a third of big femoral head arthroplasties. Each patient experienced a clinical examination and evaluated with Harris Hip Score, WOMAC, Sf-36, UCLA activity score, satisfaction VAS, anteroposterior and lateral X-rays of the hip and were followed in an outpatient setting for 2 years. Statistical analysis revealed no notable differences between the three groups regarding their demographic data however significant differences have been found between preoperative and postoperative clinical scores of each group. Also, we fail to reveal any significant differences when comparing data of all three groups at the final 2 years postoperative control regarding their clinical scores. The overall outcome of all three groups was similar, all the patients were satisfied and returned to previous level of sport activities. Short metaphyseal hip arthroplasties in young patients intending to return to previous and even high impact sport activities, similar to high functional resurfacing, big femoral head arthroplasties. Short stems with hard on hard bearing surfaces might become an alternative to standard stems and hip resurfacing.

  11. The long-term in vivo behavior of polymethyl methacrylate bone cement in total hip arthroplasty.

    Science.gov (United States)

    Oonishi, Hiroyuki; Akiyama, Haruhiko; Takemoto, Mitsuru; Kawai, Toshiyuki; Yamamoto, Koji; Yamamuro, Takao; Oonishi, Hironobu; Nakamura, Takashi

    2011-10-01

    The long-term success of cemented total hip arthroplasty (THA) has been well established. Improved outcomes, both radiographically and clinically, have resulted mainly from advances in stem design and improvements in operating techniques. However, there is concern about the durability of bone cement in vivo. We evaluated the physical and chemical properties of CMW1 bone cements retrieved from patients undergoing revision THA. CMW1 cements were retrieved from 14 patients who underwent acetabular revision because of aseptic loosening. The time in vivo before revision was 7-30 years. The bending properties of the retrieved bone cement were assessed using the three-point bending method. The molecular weight and chemical structure were analyzed by gel permeation chromatography and Fourier-transform infrared spectroscopy. The porosity of the bone cements was evaluated by 3-D microcomputer tomography. The bending strength decreased with increasing time in vivo and depended on the density of the bone cement, which we assume to be determined by the porosity. There was no correlation between molecular weight and time in vivo. The infrared spectra were similar in the retrieved cements and in the control CMW1 cements. Our results indicate that polymer chain scission and significant hydrolysis do not occur in CMW1 cement after implantation in vivo, even in the long term. CMW1 cement was stable through long-term implantation and functional loading.

  12. A comparison between patient recall and concurrent measurement of preoperative quality of life outcome in total hip arthroplasty.

    Science.gov (United States)

    Howell, Jonathan; Xu, Min; Duncan, Clive P; Masri, Bassam A; Garbuz, Donald S

    2008-09-01

    The objective is to evaluate the reliability of patients' recall of preoperative pain and function during the immediate postoperation period after total hip arthroplasty. A prospective cohort of 104 patients completed a survey about their quality of life before operation, and recalled preoperative status at 3 days, 6 weeks, and 12 weeks after operation. Quality of life was measured by the Western Ontario and McMaster University Osteoarthritis Index, the Oxford-12 hip score, and the 12-item Short-Form score. The intraclass correlation coefficient and Spearman correlation coefficient were used to compare preoperative quality of life scores to the scores recalled. The reliability of recall remained high up to 3 months postoperation. Patients are able to accurately recall their preoperative function for up to 3 months after total hip arthroplasty.

  13. Effect of clearance on cartilage tribology in hip hemi-arthroplasty.

    Science.gov (United States)

    Lizhang, Jia; Taylor, Simon D; Jin, Zhongmin; Fisher, John; Williams, Sophie

    2013-12-01

    Hemi-arthroplasty of the hip (an artificial femoral head articulating against the natural acetabulum) is used to treat fractured necks of femur; however, there is evidence that articulation causes erosion of the cartilage, resulting in pain for the patient. Parameters that may influence this cartilage erosion include head material and roughness, clearance between the head and acetabulum and activity levels of the patient. This study has assessed the effect of clearance of hemi-arthroplasty articulations on the contact stress, friction and cartilage deformation in an in vitro tribological simulation of the hemi-arthroplasty joint that applied dynamic loads and motion. It has been demonstrated that peak contact stress increased from 5.6 to 10.6 MPa as radial clearance increased from small (1.8 mm). In all samples, friction factor increased with time and was significantly less with extra-large clearances compared to small (<0.6 mm), medium (0.6-1.2 mm) and large (1.2-1.8 mm) clearances. The cartilage deformation observed was significantly greater in acetabulum samples paired to give small or extra-large clearances compared to those with medium or large clearances.

  14. Comparison of Procedural Sedation for the Reduction of Dislocated Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Jonathan E. dela Cruz

    2014-02-01

    Full Text Available Introduction: Various types of sedation can be used for the reduction of a dislocated total hip arthroplasty. Traditionally, an Opiate/Benzodiazepine combination has been employed. The use of other pharmacologic agents, such as Etomidate and Propofol, has more recently gained popularity. Currently no studies directly comparing these sedation agents have been carried out. The purpose of this study is to compare differences in reduction and sedation outcomes including recovery times of these three different sedation agents. Methods: A retrospective chart review was performed examining 198 patient’s charts who presented with dislocated total hip arthroplasty at two academic affiliated medical centers. The patients were organized into groups according to the type of sedation agent used during their reduction. The percentages of reduction and sedation complications were calculated along with overall recovery times. Reduction complications included fracture, skin or neurovascular injury, and failure of reduction requiring general anesthesia. Sedation complications included use of bag-valve mask and artificial airway, intubation, prolonged recovery, use of a reversal agent, and inability to achieve sedation. The data were then compared for each sedation agent. Results: The reduction complications rates found were 8.7% in the Propofol group, 24.68% in the Etomidate, and 28.85% in the Opiate/Benzodiazepine groups. The reduction complication rate in the Propofol group was significantly different than those of the other two agents (p≤0.01. Sedation complications were found to happen 7.25% of the time in the Propofol group, 11.69% in the Etomidate group, and 21.25% in the Opiate/ Benzodiazepine group with Propofol having complication rates significantly different than that of the Opiate/Benzodiazepine group (p=0.02. Average lengths of recovery were 25.17 minutes for Propofol, 30.83 minutes for Etomidate, and 44.35 minutes for Opiate/ Benzodiazepine with

  15. [Sports participation after joint arthroplasty].

    Science.gov (United States)

    Dauty, M; Letenneur, J

    2007-12-01

    To recommand sports activities after joint arthroplasty from the literature analysis, the French surgeon's opinion and wish patients. From the Medline data base interrogation according to keywords: Sports, Arthroplasty, Athletics, Physical training, two different readers, an orthopedic surgeon and a Physical Medicine and Rehabilitation physician selected articles in French or English language according to the level of proofs of the french classification of the Accreditation and Health Evaluation National Agency (Anaes). Professional practices were estimated by the interrogation of 30 orthopedic surgeons members of the french West Orthopaedics Society (SOO). The demand of sports practice was studied with patients recently operated for a primary total knee arthroplasty (TKA) after gonarthrosis. Twenty-two articles were selected from 305 articles obtained by the search according to keywords. Ten literature reviews are limited by the absence of prospective randomized study. A level II study and eleven level IV articles are reported. According to the subjective orthropedic surgeon's opinion, the objective results based on the joint load studied and the percentage of arthroplasty revision, sport is beneficial for the individual health but perhaps not for the arthroplasty survey. However, aerobic and leisure activities are recommended (walking, swimming, cycling) in agreement with the demand of the patients recently operated with a TKA. TKA differs from Total Hip Arthroplasty for jogging because of knee joint constraints during the knee flexion. A single study reports sports possibilities after shoulder arthroplasty and ankle arthroplasty and no study reports results after elbow arthroplasty.

  16. LEAK study : design of a nationwide randomised controlled trial to find the best way to treat wound leakage after primary hip and knee arthroplasty

    NARCIS (Netherlands)

    Löwik, Claudia A M; Wagenaar, Frank-Christiaan; van der Weegen, Walter; Poolman, Rudolf W; Nelissen, Rob G H H; Bulstra, Sjoerd K; Pronk, Yvette; Vermeulen, Karin M; Wouthuyzen-Bakker, Marjan; van den Akker-Scheek, Inge; Stevens, Martin; Jutte, Paul C

    2017-01-01

    INTRODUCTION: Total hip arthroplasty (THA) and total knee arthroplasty (TKA) are highly successful treatment modalities for advanced osteoarthritis. However, prolonged wound leakage after arthroplasty is linked to prosthetic joint infection (PJI), which is a potentially devastating complication. On

  17. Dual mobility total hip arthroplasty in hemiplegic patients

    Directory of Open Access Journals (Sweden)

    Henawy Ayman T.

    2017-01-01

    Full Text Available Introduction: The rate of cerebrovascular insults is increasing, currently leaving many patients with difficulties to maintain their balance due to muscular weakness and/or poor central control. Those patients are at risk of dislocation when total hip arthroplasty (THA is planned. Instability remains the most significant issue after primary THA especially in such groups of patients. The risk is more pronounced when other factors are added such as, older age, femoral neck fractures, avascular necrosis and/or hip osteoarthritis. Dual mobility cup (DMC is considered as a prosthesis with higher inherent stability that may help in such situation. In this patient series, we aimed to evaluate stability, clinical and radiological results of dual mobility THA done on the weak limb of hemiplegic patients. Methods: Twenty-four consecutive hemiplegic patients have undergone DMC with a mean age of 68 years. The indication for surgery was hip osteoarthritis in one third of the patients and femoral neck fractures in the remaining patients. Those patients were capable of walking prior to hospital admission despite weakness. Those patients were observed postoperatively for at least one year. Clinical results and complications were recorded. Results: After a minimum of one year, 91.6% of the patients have satisfactory results. No cases of hip or intraprosthetic dislocation were observed. Discussion: Dual mobility THA in the hemiplegic patients provides both efficacy and stability with good functional results.

  18. [A therapeutic effect analysis of femur first principle and combined anteversion technique during total hip arthroplasty].

    Science.gov (United States)

    Wang, X Q; Wu, C S; Sun, S; Wang, J; Li, W; Zhang, W

    2018-04-01

    Objective: To investigate the situation of hip dislocation with the application of "femur first" principle and "combined anteversion technique" during total hip arthroplasty. Methods: A retrospective analysis has been done on the clinical data about 104 patients(133 hips)who were diagnosed as hip disease and were treated with total hip arthroplasty by the doctors from the Department of Joint Orthorpaedics of Shandong Provincial Hospital Affiliated to Shandong University from June 2014 to June 2016, and all the prostheses applied in the operation were cementless ones.Among them, 65 patients were males, 39 females and their age was 46.6 years (ranging from 23 to 76 years) .And 29 of them underwent bilateral hip operations and 75 unilateral ones.Seventy-six cases of aseptic necrosis of the femoral head in the terminal stage, 28 cases of hip dysplasia and osteoarthritis.Surgical approach: of all the operations, 103 hips were operated on with hardinge approach, 30 with posterolateral approach.During the operation, first of all, the femoral medullary cavity was broached and then the anteversion of intramedullary broacher was measured.After that, the anteversion of the acetabular cup was calculated as 37° minus the anteversion of the broacher, and the acetabular cup was implanted at that angle.The patients' prosthesis combined anteversion, range of motion of the hip joint, operation time, hemorrhage amount, and complications had been kept record.One, three, and six months respectively after the operation, all the patients received outpatient review, and took anteroposterior and lateral position X-ray examination.Harris hip score had been applied to evaluate their hip function before the operation and six months after the operation. Results: All the patients had been operated on smoothly, with the operation time of(57.6±14.5)minutes(36-115 minutes)and hemorrhage amount of (336.5±50.8)ml(180-620 ml). The operation finding showed that the combined anteversion by employing

  19. High risk for revision after shoulder arthroplasty for failed osteosynthesis of proximal humeral fractures

    DEFF Research Database (Denmark)

    Kristensen, Marc Randall; Rasmussen, Jeppe Vejlgaard; Elmengaard, Brian

    2018-01-01

    Background and purpose - It is unclear whether previous osteosynthesis is a risk factor for inferior outcome following shoulder arthroplasty for a proximal humeral fracture. We used data from the Danish Shoulder Arthroplasty Registry (DSR) to examine this question. Patients and methods - All 285...... patients treated with a shoulder arthroplasty after failed osteosynthesis of a proximal humeral fracture reported to DSR from 2006 to 2013 were included. Each case was matched with 2 controls (570) treated with a primary shoulder arthroplasty for an acute proximal humeral fracture. Patient reported outcome...... for a shoulder arthroplasty after failed osteosynthesis was 2 with a primary arthroplasty for fracture as reference. In a separate analysis of patients treated by locking plate the mean WOOS was 46 (24), with a relative risk of revision at 1.5 with a primary arthroplasty as reference. Interpretation - Compared...

  20. Assessment of asymmetric leg loading before and after total hip arthroplasty using instrumented shoes

    NARCIS (Netherlands)

    Martínez-Ramírez, Alicia; Weenk, D.; Lecumberri, Pablo; Verdonschot, Nicolaas Jacobus Joseph; Pakvis, Dean; Veltink, Petrus H.

    2013-01-01

    The stance time and the average vertical ground reaction force measured with the instrumented shoes during walking, and their symmetry index, showed significant differences before and after total hip arthroplasty. However, the data obtained with the sit to stand test did not reveal this improvement

  1. Comparing contemporary revision burden among hip and knee joint replacement registries

    Directory of Open Access Journals (Sweden)

    Brian J. McGrory, MD, MS

    2016-06-01

    Conclusions: Revision burden has gradually decreased for hip replacements and has remained relatively constant for knee replacements both for the last 4 years and compared to historic controls. Knee revision burden was lower than hip revision burden for each period examined. Revision burden is one measure that may be helpful in following the effect of changes in surgical technique and implant design over time in registry populations and may be a helpful way to compare overall results between registries.

  2. Pre-operative Predictive Factors of Post-operative Pain in Patients With Hip or Knee Arthroplasty: A Systematic Review.

    Science.gov (United States)

    Hernández, Clara; Díaz-Heredia, Jorge; Berraquero, María Luisa; Crespo, Pablo; Loza, Estíbaliz; Ruiz Ibán, Miguel Ángel

    2015-01-01

    To analyze pre-surgical predictive factors of post-surgical pain in patients undergoing hip or knee arthoplasty. A systematic literature review was performed. We defined a sensitive strategy on Medline, Embase and Cochrane Library up to May 2013. The inclusion criteria were: patients undertaking knee and/or hip arthroplasty, adults with moderate or severe pain (≥4 on a Visual Analog Scale) in whom predictive factors of post-surgical pain were evaluated before surgery. Systematic reviews, meta-analyses, controlled trials and observational studies were selected. We excluded animals and basic science articles, reviews of prosthesis, prosthesis due to fractures, patients with rheumatic diseases or studies with mixed population in which disaggregated data was not possible to obtain. A total 37 articles of moderate quality were selected. The articles included representative patients undergoing a knee or hip arthroplasty in our country; most of them were aged 60 years or above, with osteoarthritis, and with a high rate of obesity and comorbidities. We found great variability regarding the type of studies and predictive factors. There was a strong association between post-surgical pain and the following pre-surgical factors: female gender, low socio-economic status, higher pain, comorbidities, low back pain, poor functional status, and psychological factors (depression, anxiety or catastrophic pain). There are pre-surgical factors that might influence post-surgical pain in patients undergoing a knee or hip arthroplasty. Therefore, they should be taken into account when considering an arthroplasty. Copyright © 2014 Elsevier España, S.L.U. y Sociedad Española de Reumatología y Colegio Mexicano de Reumatología. All rights reserved.

  3. [Tripolar arthroplasty for recurrent total hip prosthesis dislocation].

    Science.gov (United States)

    Beaulé, P-E; Roussignol, X; Schmalzried, T-P; Udomkiat, P; Amstutz, H-C; Dujardin, F-H

    2003-05-01

    The purpose of this study was to assess the results of revision surgery for recurrent total hip prosthesis dislocation using a tripolar prosthesis composed of a conventional stem with a mobile head of an intermediary prosthesis measuring more than 40 mm and a modified cup. This technique was used in two centers in Rouen France and Los Angeles USA. Twenty-one hips in 21 patients were operated on. The mobile heads measured 40 to 47 mm. Mean patient age was 70 years (range 29-92). The indication for the tripolar prosthesis was reserved for extremely unstable hips in patients with major risk factors for recurrent dislocation. These 21 patients had experienced 95 dislocations. The acetabular cup was custom-made for the large-diameter heads. A cemented polyethylene cup was used in 14 cases and a press-fit metal-backed around a polyethylene insert in 7. The polyethylene thickness varied from 6.5 to 16 mm for the cemented cups and 4 to 5 mm for the press-fit cups. Fourteen femoral stems were left in place as were two press-fit cups where only the inserts were changed. Mean follow-up was 5.4 years (range 3-11.8). There has been no recurrent dislocation for 20 hips. One patient experienced a dislocation one week after surgery which required a second revision procedure to reposition the acetabular implant. Final outcome was good at 7.6 years for this hip. One patient who had not had any recurrent dislocation died 4 years after the revision surgery due to a cause unrelated to the prosthesis. Two patients were lost to follow-up at 3.7 and 6 years, both were pain free and had no radiological anomalies. Infection occurred in one patient undergoing chemotherapy for a myeloma; the head and neck had to be resected. For the 20 other patients, functional outcome, assessed with the UCLA score, showed improvement in pain (5.8 preoperatively, 9.2 at last follow-up), walking (4.8 and 8 respectively), function (4 and 6 respectively), and daily activities (3.3 and 5.2 respectively). A

  4. Cost-effectiveness of positive contrast and nuclear arthrography in patients who underwent total hip arthroplasty

    International Nuclear Information System (INIS)

    Swan, J.S.; Braunstein, E.M.; Capello, W.; Wellman, H.

    1989-01-01

    The authors have compared the cost effectiveness of contrast arthrography (CA) and nuclear arthrography (NA), in which In-111 chloride is injected with the contrast material, of total hip arthroplasties. Their series included 48 cases of surgically proved loose femoral components. The cost per true-positive result was obtained by taking the total cost of the examinations in surgically proved cases and dividing by the number of true-position cases. The cost of CA was $297 and the cost of NA was $335. For CA, the cost per true positive was $1,018, and for the NA the cost per true positive was $946. In spite of higher initial cost, NA is more cost effective than CA on a cost per true-positive case basis. NA is cost effective in evaluating hip arthroplasties in which there is suspicion of a loose femoral component

  5. Characteristics of Fibromyalgia Independently Predict Poorer Long‐Term Analgesic Outcomes Following Total Knee and Hip Arthroplasty

    Science.gov (United States)

    Urquhart, Andrew G.; Hassett, Afton L.; Tsodikov, Alex; Hallstrom, Brian R.; Wood, Nathan I.; Williams, David A.; Clauw, Daniel J.

    2015-01-01

    Objective While psychosocial factors have been associated with poorer outcomes after knee and hip arthroplasty, we hypothesized that augmented pain perception, as occurs in conditions such as fibromyalgia, may account for decreased responsiveness to primary knee and hip arthroplasty. Methods A prospective, observational cohort study was conducted. Preoperative phenotyping was conducted using validated questionnaires to assess pain, function, depression, anxiety, and catastrophizing. Participants also completed the 2011 fibromyalgia survey questionnaire, which addresses the widespread body pain and comorbid symptoms associated with characteristics of fibromyalgia. Results Of the 665 participants, 464 were retained 6 months after surgery. Since individuals who met criteria for being classified as having fibromyalgia were expected to respond less favorably, all primary analyses excluded these individuals (6% of the cohort). In the multivariate linear regression model predicting change in knee/hip pain (primary outcome), a higher fibromyalgia survey score was independently predictive of less improvement in pain (estimate −0.25, SE 0.044; P fibromyalgia survey score (P = 0.00032). The fibromyalgia survey score was also independently predictive of change in overall pain and patient global impression of change. Conclusion Our findings indicate that the fibromyalgia survey score is a robust predictor of poorer arthroplasty outcomes, even among individuals whose score falls well below the threshold for the categorical diagnosis of fibromyalgia. PMID:25772388

  6. Systematic review and meta-analysis of closed suction drainage versus non-drainage in primary hip arthroplasty.

    LENUS (Irish Health Repository)

    Kelly, Enda G

    2014-03-01

    The routine use of drains in surgery has been dogmatically instituted in some disciplines. Orthopaedic surgery is one such sub-speciality. The use of postoperative closed suction drainage in total hip arthroplasty (THA) has become increasingly controversial with multiple randomised control trials performed to assess the benefit to outcome in THA. The hypothesis of this systematic review is that closed suction drainage does not infer a benefit and increase transfusion requirements of primary total hip arthroplasty patients. A systematic review and meta-analysis was conducted adhering to the PRISMA guidelines. A search of the available literature was performed on PubMed, Cochrane Central Registry of Controlled Trials, MEDLINE (OVID) and EMBASE using a combination of MeSH terms and Boolean operators. All data analysis was performed using the Cochrane Collaboration\\'s Review Manager 5.1. Sixteen studies (n=2705) were included in the analysis. Post-operative closed suction drainage was found to increase total blood loss and blood transfusion requirements (p<0.05). Surgical site infection demonstrated no significant difference between the two groups (p=0.82). No significant difference in haematoma formation between groups (p=0.19) was elicited. The routine use of closed suction drainage systems post primary hip arthroplasty is not supported by this meta-analysis. However, the heterogeneity between studies does limit the accuracy of the meta-analysis.

  7. CUSTOM TRIFLANGE ACETABULAR COMPONENTS IN REVISION HIP REPLACEMENT (EXPERIENCE REVIEW

    Directory of Open Access Journals (Sweden)

    A. A. Korytkin

    2017-01-01

    Full Text Available Extensive defects of acetabulum especially accompanied by pelvis discontinuity at the level of acetabulum pose a serious challenge in revision hip replacement and create additional complexity in fixing the acetabular component. One of the perspective options to solve the above issue is the use of custom triflange acetabular components (CTAC designed based on preoperative computer tomography given the specifics of bone defects of the patient. Purpose of the study — to evaluate the outcomes of CTAC use in revision hip replacement.Materials and methods. The authors analyzed treatment outcomes of 12 patients after revision hip replacement using additive techniques of computer simulation and 3D printing CTAC. Follow up period after the surgery averaged 7±3 months (from one to ten months. 7 out of 12 patients had acetabular defects of Paprosky 3B type, 4 patients had defects of Paprosky 3A and in one patient — of Paprosky 2C.Results. Two out of twelve patients had prosthesis dislocations that required revision hip surgery, one of those patients underwent open reduction of dislocation with wound debridement, another patient underwent replacement of articulating couple of acetabular component. Total scores under Harris Hip Score and paint VAS score prior to treatment was 28±7 and 7±1 points respectively, postoperative scores were 76±9 and 3±1 respectively.Conclusion. The application of additive techniques for revision hip replacement in patients with extensive acetabular and pelvic defects allows to make a precise preoperative planning, to restore joint rotation center, to reconstruct bone defects and to securely fix triflange acetabular component that altogether significantly improve treatment outcomes and patients satisfaction with the surgery.

  8. Preoperative diagnostic for periprosthetic joint infection prior to total knee revision arthroplasty

    Directory of Open Access Journals (Sweden)

    Leif Claassen

    2014-08-01

    Full Text Available Periprosthetic joint infection (PJI after total knee arthroplasty remains a challenging problem. The aim of this study was to evaluate the accuracy of diagnostic knee aspiration and serum inflammatory markers in diagnostic of a PJI after total knee arthroplasty. Within 2011 and 2012, 46 patients received a one- or two-stage revision arthroplasty of the knee joint. These patients received a total number of 77 operations. A preoperative aspiration was performed in each case. We analyzed the microbiological and histological examinations of the samples from the aspiration and from the revision operation and additionally estimated serum inflammatory markers. The diagnostic aspiration had a specificity of 0.87, a sensitivity of 0.39, a positive predictive value of 0.67 and a negative predictive value of 0.68. For C-reactive protein the specificity was 0.61 and the sensitivity was 0.48, the serum white blood cell count had a specificity of 0.98 and a sensitivity of 0.23. Our data queries whether diagnostic joint aspiration or serum inflammatory markers are sufficient to verify or exclude a PJI.

  9. Evaluation of the Quality of Life and Psychiatric Symptoms of Patients with Primary Coxarthrosis after Total Hip Arthroplasty.

    Science.gov (United States)

    Balik, M S; Hocaoğlu, Ç; Erkut, A; Güvercin, Y; Keskin, D

    2017-01-01

    PURPOSE OF THE STUDY In this study, it was aimed to examine the preoperative and postoperative quality of life and psychiatric symptoms of the patients with primary coxarthrosis after total hip arthroplasty. MATERIAL AND METHODS 150 patients undergone total hip arthroplasty were involved in this study. The socio-demographical data form prepared by the researchers was utilized before and after the operation in order to demonstrate disease-related socio-demographical characteristics of the patient. The Quality of Life Scale Short Form (SF-36), Beck Depression Inventory (BDI), Beck Anxiety Inventory (BAI), Harris Hip Score (HHS) and Visual Analog Scale (VSA) were implemented in the preoperative period and at 6th and 12th week after the operation. RESULTS Of the patients involved in study, 28.7% were male and 71.3% were female. Their mean age was 58.34±11.92 year. While statistically significant differences were found between the preoperative and postoperative periods in terms of physical function, physical role limitation, emotional role limitation, energy, social function, pain, and general health subscales of SF-36, no significant differences were found relating mental health subscale. In BAI, BDI, VAS, and HHS comparison, statistically significant differences were found between the preoperative and postoperative periods, except for BAI. CONCLUSIONS In this study, it was determined that primary coxarthrosis affects significantly the quality of the patients' lives in a negative way and can be accompanied by mental symptoms. After total hip arthroplasty, significant improvement was observed in quality of life, depression and pain scores. Key words: total hip prosthesis, quality of life, mental symptoms.

  10. Ultrasound gel minimizes third body debris with partial hardware removal in joint arthroplasty

    Directory of Open Access Journals (Sweden)

    Aidan C. McGrory

    2017-03-01

    Full Text Available Hundreds of thousands of revision surgeries for hip, knee, and shoulder joint arthroplasties are now performed worldwide annually. Partial removal of hardware during some types of revision surgeries may create significant amounts of third body metal, polymer, or bone cement debris. Retained debris may lead to a variety of negative health effects including damage to the joint replacement. We describe a novel technique for the better containment and easier removal of third body debris during partial hardware removal. We demonstrate hardware removal on a hip joint model in the presence and absence of water-soluble gel to depict the reduction in metal debris volume and area of spread.

  11. Incidence of delirium in postoperative patients treated with total knee and hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Felipe de Santana Bosmak

    Full Text Available Summary Introduction: Delirium is a common disorder that can potentiate mortality and comorbidity rates of patients hospitalized in intensive care units. Patients undergoing major orthopedic surgeries, such as knee and hip arthroplasty, are particularly vulnerable as they often have multiple risk factors for this disorder. Method: Descriptive study of the incidence of delirium in patients treated with total knee and hip arthroplasty, given the advanced age and comorbidities in this population. We evaluated the medical records of patients who had previously undergone the designated surgeries for identification of postoperative delirium. Results: We observed in this study an incidence of 8.92% of delirium, mostly affecting females with a mean age of 73 years and hypertension. Conclusion: The incidence of delirium in our study is similar to that observed in the general population, according to the literature. We found no correlation with sleep disorders, smoking or diabetes mellitus in this study, even though the importance of these factors for the onset of delirium is well-established in the literature.

  12. Effect of tranexamic acid administration on bleeding in primary total hip arthroplasty.

    Science.gov (United States)

    Fernández-Cortiñas, A B; Quintáns-Vázquez, J M; Gómez-Suárez, F; Murillo, O Simón; Sánchez-López, B R; Pena-Gracía, J M

    To study the efficacy of tranexamic acid to decrease perioperative bleeding in patients who have undergone a total hip arthroplasty operation and to evaluate drug safety. Observational, prospective, controlled and randomized study on the efficacy of tranexamic acid as a method to reduce bleeding in primary hip replacement surgery. We included 134 patients operated during 2014 in our centre, who were divided into 2 groups according to whether or not they had received tranexamic acid. The main study variables were haemoglobin and haematocrit levels, the amount of blood collected from the post-operative drain in the first 12, 24 and 48hours and transfusion requirements. Post-operative haemoglobin and haematocrit levels were statistically higher (Ptranexamic acid. Statistically significant differences (P=.001) were found as to the need for transfusion according to group, more transfusions were performed in the cohort that had not received tranexamic acid: 25.37% compared to 4.48% for the group with tranexamic acid. No adverse events related to administration of tranexamic acid were recorded. Administration of tranexamic acid has proved to be an effective and safe method to reduce peri-operative bleeding in patients who underwent total hip arthroplasty and avoids allogenic blood transfusion. Therefore, tranexamic acid treatment could entail a financial saving for the healthcare system and expose the patient to less risk. Copyright © 2017 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. Outcome of Revision Shoulder Arthroplasty After Resurfacing Hemiarthroplasty in Patients with Glenohumeral Osteoarthritis

    DEFF Research Database (Denmark)

    Rasmussen, Jeppe V; Olsen, Bo S; Al-Hamdani, Ali

    2016-01-01

    hemiarthroplasty was 62 points (interquartile range, 40 to 88 points). Of the 80 cases that had follow-up, 33 (41%) had an unacceptable outcome, defined as a WOOS of ≤50 points. Of the 107 cases that required a revision surgical procedure, 11 arthroplasties (10%) required a further revision surgical procedure...

  14. Loose glenoid components in revision shoulder arthroplasty: is there an association with positive cultures?

    Science.gov (United States)

    Lucas, Robert M; Hsu, Jason E; Whitney, Ian J; Wasserburger, Jory; Matsen, Frederick A

    2016-08-01

    Glenoid loosening is one of the most common causes of total shoulder failure. High rates of positive cultures of Propionibacterium and coagulase-negative staphylococcus have been found among shoulders having surgical revision for glenoid loosening. This study reviewed the culture results in a series of surgical revisions for failed total shoulder arthroplasty to determine the relationship between glenoid loosening and positive cultures. The medical records of 221 patients without obvious evidence of infection who underwent revision total shoulder arthroplasty were reviewed to examine the association between the security of fixation of the glenoid component and the results of cultures obtained at revision surgery. Of the revised shoulders, 53% had positive cultures; 153 of the shoulders (69%) had a loose glenoid component, whereas 68 (31%) had secure glenoid component fixation. Of the 153 loose glenoid components, 82 (54%) had at least 1 positive culture and 44 (29%) had 2 or more positive cultures of the same microorganism. Similarly, of the 68 secure glenoid components, 35 (51%) had at least 1 positive culture (P = .77) and 14 (21%) had 2 or more positive cultures of the same microorganism (P = .25). Explanted glenoid components that were loose had a higher rate of culture positivity (56% [24/43]) in comparison to explanted glenoid components that were well fixed (13% [1/8]) (P = .05). Propionibacterium and coagulase-negative staphylococcus are commonly recovered in revision shoulder arthroplasty, whether or not the glenoid components are loose. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  15. Radiographic cup position following posterior and lateral approach to total hip arthroplasty. An explorative randomized controlled trial

    DEFF Research Database (Denmark)

    Kruse, Christine; Rosenlund, Signe; Broeng, Leif

    2018-01-01

    The two most common surgical approaches to total hip arthroplasty are the posterior approach and lateral approach. The surgical approach may influence cup positioning and restoration of the offset, which may affect the biomechanical properties of the hip joint. The primary aim was to compare cup...... arthroplasty using posterior approach or lateral approach. Postoperative radiographs from 38 patients in each group were included in this study for measurement of cup anteversion and inclination. Femoral offset, cup offset, total offset, abductor moment arm and leg length discrepancy were measured...... approach group had a larger mean femoral offset of 4.3mm (95% CI, -7.4 to -1.3, p = 0.006), mean total offset of 6.3mm (95% CI, -9.6 to -3; pcup anteversion but less...

  16. Blood Conservation Strategies in Total Hip and Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    David Liu

    2015-01-01

    Full Text Available Peri-operative blood management is one of a number of components important for successful patient care in total joint arthroplasty and surgeons should be proactive in its application. The aims of blood conservation are to reduce the risks of blood transfusion whilst at the same time maximizing haemaglobin in the post-operative period, thereby leading to a positive effect on early and long term outcomes and costs. An individualized strategy based on patient specific risk factors, anticipated blood loss and co-morbidities is useful in achieving this aim. Multiple blood conservation strategies are available in the pre-operative, intra-operative and post-operative periods and can be utilised either individually or in combination. Recent literature has highlighted the importance of identifying and correcting pre-operative anaemia, salvaging peri-operative red cells and the use of tranexamic acid in reducing blood loss. Given total hip and knee arthroplasty is an elective procedure, a zero allogenic blood transfusion rate should be the aim and an achievable goal.

  17. The acetabulum: A prospective study of three-phase bone and indium white blood cell scintigraphy following porous-coated hip arthroplasty

    International Nuclear Information System (INIS)

    Oswald, S.G.; Van Nostrand, D.; Savory, C.G.; Anderson, J.H.; Callaghan, J.J.

    1990-01-01

    Although few studies address the use of three-phase bone scanning (TPBS) and indium-111-labeled white blood cell scintigraphy ( 111 In-WBC) in hip arthroplasty utilizing a porous-coated prosthesis, the literature suggests that scintigraphic patterns in the uncomplicated patient may differ from that seen with the cemented prosthesis. In an attempt to determine the scintigraphic natural history, 25 uncomplicated porous-coated hip arthroplasties in 21 patients were prospectively studied with serial TPBS and 111I n-WBC at approximately 7 days, and 3, 6, 12, 18, and 24 mo postoperatively. This report deals with findings related to the acetabulum. All 25 prostheses (144 of 144 scans) demonstrated increased uptake on the bone-phase images. Although this activity decreased with time, 76% had persistent uptake at 24 mo. Twenty-three of 25 prostheses (126 of 140 scans) showed increased uptake on 111 In-WBC scintigraphy, invariably decreasing with time, but with 37% having significant uptake at 24 mo. Scintigraphic patterns in the uncomplicated porous-coated hip arthroplasty patient appear to differ from patterns described in cemented prostheses

  18. Alternative Payment Models Should Risk-Adjust for Conversion Total Hip Arthroplasty: A Propensity Score-Matched Study.

    Science.gov (United States)

    McLawhorn, Alexander S; Schairer, William W; Schwarzkopf, Ran; Halsey, David A; Iorio, Richard; Padgett, Douglas E

    2017-12-06

    For Medicare beneficiaries, hospital reimbursement for nonrevision hip arthroplasty is anchored to either diagnosis-related group code 469 or 470. Under alternative payment models, reimbursement for care episodes is not further risk-adjusted. This study's purpose was to compare outcomes of primary total hip arthroplasty (THA) vs conversion THA to explore the rationale for risk adjustment for conversion procedures. All primary and conversion THAs from 2007 to 2014, excluding acute hip fractures and cancer patients, were identified in the National Surgical Quality Improvement Program database. Conversion and primary THA patients were matched 1:1 using propensity scores, based on preoperative covariates. Multivariable logistic regressions evaluated associations between conversion THA and 30-day outcomes. A total of 2018 conversions were matched to 2018 primaries. There were no differences in preoperative covariates. Conversions had longer operative times (148 vs 95 minutes, P reimbursement models shift toward bundled payment paradigms, conversion THA appears to be a procedure for which risk adjustment is appropriate. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Postoperative pain treatment after total hip arthroplasty

    DEFF Research Database (Denmark)

    Højer Karlsen, Anders Peder; Geisler, Anja; Petersen, Pernille Lykke

    2015-01-01

    Treatment of postoperative pain should rely on results from randomized controlled trials and meta-analyses of high scientific quality. The efficacy of a particular intervention may depend on the type of surgical procedure, which supports the reporting of "procedure-specific" interventions. The aim...... of this systematic review was to document the procedure-specific evidence for analgesic interventions after total hip arthroplasty (THA). This PRISMA-compliant and PROSPERO-registered review includes randomized placebo-controlled trials (RCTs) of medication-based analgesic interventions after THA. Endpoints were......, and lumbar plexus block reduced nausea and pruritus. The GRADE-rated quality of evidence ranged from low to very low throughout the analyses. This review demonstrated, that some analgesic interventions may have the capacity to reduce mean opioid requirements and/or mean pain intensity compared with controls...

  20. Difficult acetabular revision. A preliminary report.

    Science.gov (United States)

    Newport, M L; Stuchin, S A; Frankel, V H; Zuckerman, J

    1986-01-01

    Thirteen patients (14 hips) underwent revision from conventional cemented total hip arthroplasty to uncemented acetabular threaded screw-in components and cementless femoral press-fit stems by means of the Autophor, Biofit, and Ti-Thread designs. The patients suffered from all forms of primary hip disease except rheumatoid arthritis; their average age was 34 years. The average preoperative Harris hip score was 39.4; the average postoperative score was 71.2 at six months, 90.6 at one year, and 91.6 at two years. Complications included two femoral shaft fractures, one femoral nerve palsy, and one dislocation. No signs have been observed of loosening or migration as of an early (6-24 months) follow-up.

  1. Multimodal perioperative care plus immunonutrition versus traditional care in total hip arthroplasty: a randomized pilot study.

    Science.gov (United States)

    Alito, Miguel Aprelino; de Aguilar-Nascimento, José Eduardo

    2016-04-02

    Multimodal protocols of perioperative care may enhance postoperative recovery. However, limited information is available on preoperative immune and carbohydrate (CHO)-enriched drinks in patients undergoing hip arthroplasty. We aimed to investigate the effect of a multimodal protocol (ACERTO protocol) plus preoperative immune nutrition on the length of stay (LOS) and the postoperative acute phase response of patients undergoing total hip arthroplasty. Thirty-two patients (mean age, 58 years; range, 26-85 years; 16 males) were randomized to receive either the ACERTO protocol (n = 15, ACERTO Group), which consisted of 6 h preoperative fasting for solids, an oral drink (200 mL of 12.5 % maltodextrin) up to 2 h before induction of anesthesia, restricted intravenous fluids (only 1000 mL of crystalloid fluid after surgery) and preoperative immune nutrition (600 mL/day of Impact - Nestlé, Brazil) for five days prior to surgery, or traditional care (n = 17; control group), which consisted of 6-8 h preoperative fasting, intravenous hydration until the 1(st) postoperative day and no preoperative immune supplementation. The main endpoint was LOS. C-reactive protein (CRP) was the secondary endpoint and was assessed during induction of anesthesia and on postoperative day 2. Neither deaths nor postoperative complications occurred. The median LOS was 3 (2-5) days in the ACERTO group and 6 (3-8) days in controls (P care plus preoperative immune nutrition may decrease LOS and postoperative CRP levels in total hip arthroplasty. NCT02580214.

  2. Early patient-reported outcomes versus objective function after total hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Luna, I E; Kehlet, H; Peterson, B

    2017-01-01

    AIMS: The purpose of this study was to assess early physical function after total hip or knee arthroplasty (THA/TKA), and the correlation between patient-reported outcome measures, physical performance and actual physical activity (measured by actigraphy). PATIENTS AND METHODS: A total of 80...... patients aged 55 to 80 years undergoing THA or TKA for osteoarthritis were included in this prospective cohort study. The main outcome measure was change in patient reported hip or knee injury and osteoarthritis outcome score (HOOS/KOOS) from pre-operatively until post-operative day 13 (THA) or 20 (TKA...

  3. The Utility of Digital Linear Tomosynthesis Imaging of Total Hip Joint Arthroplasty with Suspicion of Loosening: A Prospective Study in 40 Patients

    Science.gov (United States)

    Göthlin, Jan H.

    2013-01-01

    Aim. The clinical utility of digital linear tomosynthesis in musculoskeletal applications has been validated in only a few reports. Technical performance and utility in hip prosthesis imaging have been discussed in technical reports, but no clinical evaluation has been reported. The purpose of the current study was to assess the added clinical utility of digital linear tomosynthesis compared to radiography in loosening of total hip joint arthroplasty. Materials and Methods. In a prospective study, radiography and digital tomosynthesis were performed in 40 consecutive patients with total hip arthroplasty referred for suspect prosthesis loosening. Tomosynthesis images were compared to anterior-posterior (AP) and cross-table lateral radiographs regarding demarcation and extent of demineralization and osteolysis. Further noted were skeletal fractures, cement fractures, fragmentation, and artifacts interfering with the diagnosis. Results. Tomosynthesis was superior to radiography with sharper delineation of demineralization and osteolysis in the AP projection. A limitation was the inability to generate lateral tomosynthesis images, with inferior assessment of the area anterior and posterior to the acetabular cup compared to cross-table radiographs. Artifacts interfering with diagnosis were found in one hip. Conclusion. Tomosynthesis improved evaluation of total hip arthroplasty in the AP projection but was limited by the lack of lateral projections. PMID:24078921

  4. The Utility of Digital Linear Tomosynthesis Imaging of Total Hip Joint Arthroplasty with Suspicion of Loosening: A Prospective Study in 40 Patients

    Directory of Open Access Journals (Sweden)

    Jan H. Göthlin

    2013-01-01

    Full Text Available Aim. The clinical utility of digital linear tomosynthesis in musculoskeletal applications has been validated in only a few reports. Technical performance and utility in hip prosthesis imaging have been discussed in technical reports, but no clinical evaluation has been reported. The purpose of the current study was to assess the added clinical utility of digital linear tomosynthesis compared to radiography in loosening of total hip joint arthroplasty. Materials and Methods. In a prospective study, radiography and digital tomosynthesis were performed in 40 consecutive patients with total hip arthroplasty referred for suspect prosthesis loosening. Tomosynthesis images were compared to anterior-posterior (AP and cross-table lateral radiographs regarding demarcation and extent of demineralization and osteolysis. Further noted were skeletal fractures, cement fractures, fragmentation, and artifacts interfering with the diagnosis. Results. Tomosynthesis was superior to radiography with sharper delineation of demineralization and osteolysis in the AP projection. A limitation was the inability to generate lateral tomosynthesis images, with inferior assessment of the area anterior and posterior to the acetabular cup compared to cross-table radiographs. Artifacts interfering with diagnosis were found in one hip. Conclusion. Tomosynthesis improved evaluation of total hip arthroplasty in the AP projection but was limited by the lack of lateral projections.

  5. Aloenxerto circunferencial de femur proximal em cirurgia de revisäo de artroplastia total de quadril: relato de casos com seguimento mínimo de 20 anos Circumferential proximal femoral allografts in revision surgery on total hip arthroplasty: case reports with a minimum follow-up of 20 years

    Directory of Open Access Journals (Sweden)

    Bruno Dutra Roos

    2012-01-01

    Full Text Available Dentre as opções para reconstrução femoral em cirurgias de revisão de artroplastia total do quadril (RATQ em defeitos circunferenciais extensos está a utilização de aloenxerto de fêmur proximal. O seu uso permite a correção do mecanismo abdutor do quadril e da discrepância de comprimento dos membros inferiores, além de apresentar potencial osteocondutivo. Os autores relatam os achados clínicos e radiográficos de dois casos de RATQ com uso desta técnica, em seguimento mínimo de 20 anos.Among the options for femoral reconstruction in total hip arthroplasty (THA revision procedures, in cases of extensive circumferential defects, is the use of proximal femoral allografts. This technique makes it possible to correct the hip abductor mechanism and the leg length discrepancy, as well as presenting osteoconductive potential. The authors report the clinical and radiographic results from two cases of THA revision using this technique, with a minimum follow-up of 20 years.

  6. Evaluation of the Function and Quality of Life after Total Hip Arthroplasty by Different Approaches

    Directory of Open Access Journals (Sweden)

    Paulo Araújo

    2017-09-01

    Conclusion: After 24 months post total hip arthroplasty there are no differences between the two approaches with regard to function or quality of life. However, the patients operated by the anterolateral approach had greater muscle strength deficits and higher percentage of positive Trendelenburg test.

  7. Hip joint replacement

    Science.gov (United States)

    Hip arthroplasty; Total hip replacement; Hip hemiarthroplasty; Arthritis - hip replacement; Osteoarthritis - hip replacement ... Your hip joint is made up of 2 major parts. One or both parts may be replaced during surgery: ...

  8. Clinical accuracy of a patient-specific femoral osteotomy guide in minimally-invasive posterior hip arthroplasty.

    Science.gov (United States)

    Schneider, Adrian K; Pierrepont, Jim W; Hawdon, Gabrielle; McMahon, Stephen

    2018-04-01

    Patient specific guides can be a valuable tool in improving the precision of planned femoral neck osteotomies, especially in minimally invasive hip surgery, where bony landmarks are often inaccessible. The aim of our study was to validate the accuracy of a novel patient specific femoral osteotomy guide for THR through a minimally invasive posterior approach, the direct superior approach (DSA). As part of our routine preoperative planning 30 patients underwent low dose CT scans of their arthritic hip. 3D printed patient specific femoral neck osteotomy guides were then produced. Intraoperatively, having cleared all soft tissue from the postero-lateral neck of the enlocated hip, the guide was placed and pinned onto the posterolateral femoral neck. The osteotomy was performed using an oscillating saw and the uncemented hip components were implanted as per routine. Postoperatively, the achieved level of the osteotomy at the medial calcar was compared with the planned level of resection using a 3D/2D matching analysis (Mimics X-ray module, Materialise, Belgium). A total of 30 patients undergoing uncemented Trinity™ acetabular and TriFit TS™ femoral component arthroplasty (Corin, UK) were included in our analysis. All but one of our analysed osteotomies were found to be within 3 mm from the planned height of osteotomy. In one patient the level of osteotomy deviated 5 mm below the planned level of resection. Preoperative planning and the use of patient specific osteotomy guides provides an accurate method of performing femoral neck osteotomies in minimally invasive hip arthroplasty using the direct superior approach. IV (Case series).

  9. The use of allograft bone during the course of femoral reconstruction in hip revision arthroplasty

    International Nuclear Information System (INIS)

    David, A.; Morgan, F.; Imran Ilyas

    1999-01-01

    We have studied 61 patients who underwent femoral revision surgery requiring allograft reconstruction of the skeleton between 1987 and 1995. The group had a mean age of 68 years with a mean follow-up of 5.1 years. The preoperative Harris hip score was increased from 30 points to a postoperative score of 69 points. A rerevision rate of 20% was noted. Segmental anomalies were classified according to the American Academy of Orthopaedic Surgeons system. Subgroups were analysed according to the classification and relative indications for the use of impaction allografting, corticocancellous strut grafting, anatomic specific allografts and calcar allografts were devised. This paper details the results of those subgroups and outlines pitfalls and problems associated with complex surgery of this type

  10. Primary vs Conversion Total Hip Arthroplasty: A Cost Analysis

    Science.gov (United States)

    Chin, Garwin; Wright, David J.; Snir, Nimrod; Schwarzkopf, Ran

    2018-01-01

    Introduction Increasing hip fracture incidence in the United States is leading to higher occurrences of conversion total hip arthroplasty (THA) for failed surgical treatment of the hip. In spite of studies showing higher complication rates in conversion THA, the Centers for Medicare and Medicaid services currently bundles conversion and primary THA under the same diagnosis-related group. We examined the cost of treatment of conversion THA compared with primary THA. Our hypothesis is that conversion THA will have higher cost and resource use than primary THA. Methods Fifty-one consecutive conversion THA patients (Current Procedure Terminology code 27132) and 105 matched primary THA patients (Current Procedure Terminology code 27130) were included in this study. The natural log-transformed costs for conversion and primary THA were compared using regression analysis. Age, gender, body mass index, American Society of Anesthesiologist, Charlson comorbidity score, and smoker status were controlled in the analysis. Conversion THA subgroups formed based on etiology were compared using analysis of variance analysis. Results Conversion and primary THAs were determined to be significantly different (P conversion THA has significantly greater cost and resource use than primary THA. In order to prevent disincentives for treating these complex surgical patients, reclassification of conversion THA is needed, as they do not fit together with primary THA. PMID:26387923

  11. Sonographic findings after total hip arthroplasty: normal and complications

    International Nuclear Information System (INIS)

    Lee, Kyoung Rok; Seon, Young Seok; Choi, Ji He; Kim, Sun Su; Kim, Se Jong; Park, Byong Lan; Kim, Byoung Geun

    2002-01-01

    The purpose of this study was to determine the efficacy of sonography in the evaluation of normal pseudocapsular morphology and the detection of complications after total hip arthroplasty. Between Janvary 1997 and June 2000, 47 patients (35 men and 12 women aged 24 to 84 (mean, 61) years) using real-time linear-array, convex US units with 3.5-MHz and 10-MHz transducers. Normal capsular morphology in 30 with total hip replacements, who had been asymptomatic for at least one year, was studied, and the prosthetic joint infection demonstrated in six of 17 who had experienced was confirmed at surgery or by US-guided aspiration. Sonograms indicated that a normal pseudocapsule lay straight over the neck of the prosthesis or was slightly convex toward the neck , and that the mean bone-to-pseudocapsule distance was 2.9 mm. However, in the 11 symptomatic patients in whom no evidence of infection was revealed by cultures, th mean distance was 4.7 mm; in the remaining six patients, whose joints were infected (a condition strongly suggested by the presence of extracapsular fluid), the mean distance was 5.5 mm, with no significant difference between the two groups. Sonography can be used to evaluate normal caspular morphology after total hip replacement and to diagnose infection around hip prostheses. In all patients in whom sonography revealed the presence of extra-articular fluid, infection had occurred

  12. Sonographic findings after total hip arthroplasty: normal and complications

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyoung Rok; Seon, Young Seok; Choi, Ji He; Kim, Sun Su; Kim, Se Jong; Park, Byong Lan; Kim, Byoung Geun [Kwangju Christian Hospital, Kwangju (Korea, Republic of)

    2002-04-01

    The purpose of this study was to determine the efficacy of sonography in the evaluation of normal pseudocapsular morphology and the detection of complications after total hip arthroplasty. Between Janvary 1997 and June 2000, 47 patients (35 men and 12 women aged 24 to 84 (mean, 61) years) using real-time linear-array, convex US units with 3.5-MHz and 10-MHz transducers. Normal capsular morphology in 30 with total hip replacements, who had been asymptomatic for at least one year, was studied, and the prosthetic joint infection demonstrated in six of 17 who had experienced was confirmed at surgery or by US-guided aspiration. Sonograms indicated that a normal pseudocapsule lay straight over the neck of the prosthesis or was slightly convex toward the neck , and that the mean bone-to-pseudocapsule distance was 2.9 mm. However, in the 11 symptomatic patients in whom no evidence of infection was revealed by cultures, th mean distance was 4.7 mm; in the remaining six patients, whose joints were infected (a condition strongly suggested by the presence of extracapsular fluid), the mean distance was 5.5 mm, with no significant difference between the two groups. Sonography can be used to evaluate normal caspular morphology after total hip replacement and to diagnose infection around hip prostheses. In all patients in whom sonography revealed the presence of extra-articular fluid, infection had occurred.

  13. Bilateral Total Hip Arthroplasty in Femoral Head Avascular Necrosis: Functional Outcomes and Complications

    Directory of Open Access Journals (Sweden)

    Afshin Taheriazam

    2016-06-01

    Full Text Available Total hip arthroplasty (THA is one of the successful and cost-benefit surgical treatments. One-stage bilateral THA (BTHA offers many benefits. However, there are concerns about the safety of the procedure and higher complications. We aimed to evaluate the complications and outcomes of one-stage BTHA with Hardinge approach for femoral head avascular necrosis patients. A total of 60 patients from April 2009 and May 2013, were underwent one-stage bilateral total hip arthroplasty (BTHA in Milad and Erfan hospitals, Tehran, Iran. A prospective analysis of the functional outcomes and complications of one-stage BTHA through Hardinge approach in patients with femoral head avascular necrosis (AVN performed. We evaluated all patients clinically and radiologically with serial follow-ups. A clinical hip score based upon the modified Harris Hip Score (MHHS was performed preoperatively and again postoperatively. During period of study 44 men (73.3% and 16 women (26.6% with a mean age of 31.40±4.08 years (range 25 to 36 years at the time of presentation were entered. The mean surgical time was 2.6±0.38 hrs. The mean hospital stay was 3 .50±0.72 days. Hemoglobin level decreased significa ntly after operation (P= 0.046. There was no reported patient with perioperative death, deep venous thrombosis, pulmonary embolism, infection, dislocation, periprosthetic fracture or heterotrophic ossification. The mean preoperative MHHS score was 47.93±7.33 in patients. MHHS score i mproved to 95.06±3.47 in the last follow-up (P=0.0001.Our results recommend the use of one-stage BTHA through Hardinge approach in femoral head avascular necrosis patients.

  14. Fast track in total hip and knee arthroplasty--experiences from Hvidovre University Hospital, Denmark

    DEFF Research Database (Denmark)

    Husted, Henrik; Holm, Gitte

    2006-01-01

    This study investigated whether unselected patients operated on with total hip arthroplasty (THA) or total knee arthroplasty (TKA) could accomplish a self-developed accelerated track, ANORAK-HH, with a planned length of stay (LOS) of maximum 5 days and patient satisfaction at all parts of the track...... and a planned LOS of maximum 5 days. 22 patient characteristics and 11 satisfaction parameters were registered as well as readmissions within 3 months. 95% of patients had a LOS of maximum 5 days with a mean of 3.9 days. Median and mean values of satisfaction for the entire track were 10 and 9.4 out of 10...

  15. 99Tcm-MDP imaging for the diagnosis of joint infection after total hip arthroplasty

    International Nuclear Information System (INIS)

    Li Yuan; Wang Qian; Yue Minggang

    2013-01-01

    Objective: To investigate the value of 99 Tc m -MDP imaging for the differential diagnosis between infection and aseptic loosening after total hip arthroplasty. Methods: During February 2008 to August 2011, 74 patients (32 males, 42 females, average age (64.3±11.2) years) with hip pain after arthroplasty underwent 3-phase (blood flow, blood pool and bone phases) 99 Tc m -MDP imaging. All patients had measurements of serum C reactive protein (CRP) and erythrocyte sedimentation rate (ESR). Joint infection was defined as either increased peri-prosthetic soft tissue activity during perfusion and blood pool phases or increased peri-prosthetic bone activity during uptake phase, or positive in all 3 phases. Aseptic loosening was defined as having negative 99 Tc m -MDP in all 3 phases. Clinical diagnosis was chosen as the gold standard. The blood flow-pool imaging was compared with the serum examinations. χ 2 test was used for statistical analysis. Results: There were 74 symptomatic joints in 74 patients, including 24 joint infections and 50 aseptic loosening. For the detection of peri-prosthetic infection, combined perfusion-blood-pool phase was more accurate than bone uptake phase (90.5% (67/74) vs 55.4% (41/74); χ 2 =23.159, P<0.001), with the sensitivity of 91.7% (22/24) vs 70.8% (17/24) and specificity of 90.0% (45/50) vs 48.0% (24/50), respectively. The blood flow-pool imaging was also more accurate than CRP (73.0% (54/74); χ 2 =7.656, P<0.05) and ESR (71.6% (53/74); χ 2 =8.633, P<0.05), respectively. Conclusion: 99 Tc m -MDP perfusion/blood flow-pool imaging is an accurate modality for differentiating peri-prosthetic infection from aseptic loosening in patients with hip pain after arthroplasty. (authors)

  16. Endotoxins in surgical instruments of hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Vania Regina Goveia

    2016-06-01

    Full Text Available Abstract OBJECTIVE To investigate endotoxins in sterilized surgical instruments used in hip arthroplasties. METHOD A descriptive exploratory study conducted in a public teaching hospital. Six types of surgical instruments were selected, namely: acetabulum rasp, femoral rasp, femoral head remover, chisel box, flexible bone reamer and femoral head test. The selection was based on the analysis of the difficulty in removing bone and blood residues during cleaning. The sample was made up of 60 surgical instruments, which were tested for endotoxins in three different stages. The EndosafeTM Gel-Clot LAL (Limulus Amebocyte Lysate method was used. RESULT There was consistent gel formation with positive analysis in eight instruments, corresponding to 13.3%, being four femoral rasps and four bone reamers. CONCLUSION Endotoxins in quantity ≥0.125 UE/mL were detected in 13.3% of the instruments tested.

  17. Clinical Outcomes and 90-Day Costs Following Hemiarthroplasty or Total Hip Arthroplasty for Hip Fracture.

    Science.gov (United States)

    Nichols, Christine I; Vose, Joshua G; Nunley, Ryan M

    2017-09-01

    In the era of bundled payments, many hospitals are responsible for costs from admission through 90 days postdischarge. Although bundled episodes for hip fracture will have a separate target price for the bundle, little is known about the 90-day resource use burden for this patient population. Using Medicare 100% Standard Analytic Files (2010-2014), we identified patients undergoing hemiarthroplasty or total hip arthroplasty (THA). Patients were aged 65 and older with admitting diagnosis of closed hip fracture, no concurrent fractures of the lower limb, and no history of hip surgery in the prior 12 months baseline. Continuous Medicare-only enrollment was required. Complications, resource use, and mortality from admission through 90 days following discharge (follow-up) were summarized. Four cohorts met selection criteria for analysis: (1) hemiarthroplasty diagnosis-related group (DRG) 469 (N = 19,634), (2) hemiarthroplasty DRG 470 (N = 77,744), (3) THA DRG 469 (N = 1686), and (4) THA DRG 470 (N = 9314). All-cause mortality during the study period was 51.6%, 29.5%, 48.1%, and 24.9% with mean 90-day costs of $28,952, $19,243, $29,763, and $18,561, respectively. Most of the patients waited 1 day from admission to surgery (41%-51%). Incidence of an all-cause complication was approximately 70% in each DRG 469 cohort and 14%-16% in each DRG 470 cohort. This study confirms patients with hip fracture are a costly subpopulation. Tailored care pathways to minimize post-acute care resource use are warranted for these patients. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.

  18. Do patient expectations about arthroplasty at initial presentation for hip or knee pain differ by sex and ethnicity?

    Science.gov (United States)

    Lavernia, Carlos J; Contreras, Juan S; Parvizi, Javad; Sharkey, Peter F; Barrack, Robert; Rossi, Mark D

    2012-10-01

    Many studies show gender and ethnic differences in healthcare utilization and outcomes. Patients' presurgical cognitions regarding surgical outcomes also may vary by gender and ethnicity and play a role in explaining utilization and outcome differences. However, it is unclear whether and to what extent gender and ethnicity play a role in patients' presurgical cognitions. Do gender and ethnicity influence outcome expectations? Is arthroplasty-related knowledge affected by gender and ethnicity? Do gender and ethnicity influence willingness to pay for surgery? In a prospective, multicenter study we gave 765 patients an anonymous questionnaire on expectations, arthroplasty knowledge, and preferences before their consultation for hip and/or knee pain, from March 2005 to July 2007. Six hundred seventy-two of the 765 patients (88%) completed questionnaires. Non-Hispanics and men were more likely to indicate they would be able to engage in more activities. Non-Hispanics and men had greater arthroplasty knowledge. Hispanics and women were more likely to report they would not pay for a total joint arthroplasty (TJA) relative to non-Hispanics and men. Sex and ethnic differences in patients presenting for their initial visit to the orthopaedists for hip or knee pain influence expectations, knowledge, and preferences concerning TJAs. Longitudinal study of relationships between patients' perceptions and utilization or outcomes regarding TJA is warranted.

  19. No Correlation Between Press Ganey Survey Responses and Outcomes in Post-Total Hip Arthroplasty Patients.

    Science.gov (United States)

    Chughtai, Morad; Gwam, Chukwuweike U; Khlopas, Anton; Sodhi, Nipun; Delanois, Ronald E; Spindler, Kurt P; Mont, Michael A

    2018-03-01

    In the era of the online orthopedic market, patients tend to equate publicly available online satisfaction surveys with what they presume their ultimate surgical outcome will be. Therefore, the purpose of this study was to assess whether there is a correlation between Press Ganey (PG) scores and (1) Hip Western Ontario and McMaster Universities Osteoarthritis Index and Harris Hip Score; (2) Short Form-12 and Short Form-36 scores; (3) University of California Los Angeles and Visual Analog Scale scores assessed at a mean of 3 years (range, 1 to 6 years) after surgery. In addition, we assessed whether (4) these correlations persist in patients who were evaluated under 2 years and 3 or more years after surgery. Six-hundred ninety-two patients from November 2009 to January 2015 were identified from our institutional PG database. One-hundred ninety (27%) responded to the survey. One-hundred forty-nine (78%) patients were given the total hip arthroplasty assessment tools at a minimum of 2-year follow-up, and 33 patients (17%) completed their survey before 2 years after surgery. We assessed whether overall hospital rating scores correlated with the above assessment tools. Pearson correlation analysis revealed no correlation between the PG survey score and the assessment tools. HHS had the highest correlation coefficient (r = .120; P = .316); however, this was not significant. After removing the patients who had their follow-up survey administered under 2 years after surgery (33 patients), there was still no statistically significant correlation between the above-mentioned outcome scores and PG overall hospital rating (P > .05). No statistically significant relationship was found between commonly used total hip arthroplasty assessment tools and the PG overall hospital rating. Based on these results, PG surveys may not be a suitable implementation of the Center for Medicare and Medicaid services. A set of measures that can be widely collected and reported by hospitals for

  20. The mechanical effect of the existing cement mantle on the in-cement femoral revision.

    LENUS (Irish Health Repository)

    Keeling, Parnell

    2012-08-01

    Cement-in-cement revision hip arthroplasty is an increasingly popular technique to replace a loose femoral stem which retains much of the original cement mantle. However, some concern exists regarding the retention of the existing fatigued and aged cement in such cement-in-cement revisions. This study investigates whether leaving an existing fatigued and aged cement mantle degrades the mechanical performance of a cement-in-cement revision construct.

  1. Prospective analyses of female urinary incontinence symptoms following total hip arthroplasty.

    Science.gov (United States)

    Okumura, Keiko; Yamaguchi, Kumiko; Tamaki, Tatsuya; Oinuma, Kazuhiro; Tomoe, Hikaru; Akita, Keiichi

    2017-04-01

    Some patients with hip osteoarthritis report that urinary incontinence (UI) is improved following total hip arthroplasty (THA). However, the type and severity of UI remain unclear. In this study, we hypothesize that both stress urinary incontinence (SUI) and urge urinary incontinence (UUI) are improved after THA. We assess the characteristics of UI and discuss the anatomical factors related to UI and THA for improved treatment outcome. Fifty patients with UI who underwent direct anterior-approach THA were evaluated. Type of UI was assessed using four questionnaires: Core Lower Urinary Tract Symptom Score (CLSS), Urogenital Distress Inventory Short Form (UDI-6), International Prostate Symptom Score (IPSS), and Overactive Bladder Symptom Score (OABSS). Uroflowmetry and postvoid residual urine were measured using ultrasound technology. Hip-joint function was evaluated using Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and range of motion (ROM). Of the 50 patients, 21 had SUI, 16 had mixed urinary incontinence (MUI), and eight had urgency urinary incontinence (UUI). In total, 36 patients were better than improved (72 %). The rate of cured and improved was 76 % for SUI, 100 % MUI, and 50 % UUI. The improvement of ROM was more significant in cured or improved patients than in stable or worse patients. Improvement in mild UI may be an added benefit for those undergoing THA for hip-joint disorders. These data suggest that for patients with hip-joint disorder, hip-joint treatment could prove to also be a useful treatment for UI.

  2. Long-Term Outcome after Rehabilitation of Bilateral Total Hip Arthroplasty in Renal Transplant Recipient – A Case Report

    Directory of Open Access Journals (Sweden)

    Erieta Nikolikj Dimitrova

    2016-02-01

    CONCLUSION: Rehabilitation is integral part of multidisciplinary treatment of renal transplant recipient after total hip arthroplasty. Regular exercise training of these patients is very important for improving of their long-term outcome.

  3. Assessment of changes in gait parameters and vertical ground reaction forces after total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Bhargava P

    2007-01-01

    Full Text Available The principal objectives of arthroplasty are relief of pain and enhancement of range of motion. Currently, postoperative pain and functional capacity are assessed largely on the basis of subjective evaluation scores. Because of the lack of control inherent in this method it is often difficult to interpret data presented by different observers in the critical evaluation of surgical method, new components and modes of rehabilitation. Gait analysis is a rapid, simple and reliable method to assess functional outcome. This study was undertaken in an effort to evaluate the gait characteristics of patients who underwent arthroplasty, using an Ultraflex gait analyzer. Materials and Methods: The study was based on the assessment of gait and weight-bearing pattern of both hips in patients who underwent total hip replacement and its comparison with an age and sex-matched control group. Twenty subjects of total arthroplasty group having unilateral involvement, operated by posterior approach at our institution with a minimum six-month postoperative period were selected. Control group was age and sex-matched, randomly selected from the general population. Gait analysis was done using Ultraflex gait analyzer. Gait parameters and vertical ground reaction forces assessment was done by measuring the gait cycle properties, step time parameters and VGRF variables. Data of affected limb was compared with unaffected limb as well as control group to assess the weight-bearing pattern. Statistical analysis was done by′t′ test. Results: Frequency is reduced and gait cycle duration increased in total arthroplasty group as compared with control. Step time parameters including Step time, Stance time and Single support time are significantly reduced ( P value < .05 while Double support time and Single swing time are significantly increased ( P value < .05 in the THR group. Forces over each sensor are increased more on the unaffected limb of the THR group as compared to

  4. Patient education and rehabilitation after hip arthroplasty in an Italian spa center: a pilot study on its feasibility

    Science.gov (United States)

    Musumeci, Alfredo; Pranovi, Giulia; Masiero, Stefano

    2018-05-01

    Nowadays, some spa centers are suitable for providing rehabilitative and preventive treatment in association with traditional spa therapy. This study aims to evaluate the feasibility and the effectiveness of an intensive rehabilitation program after hip arthroplasty in an Italian spa center. Early after total hip arthroplasty for severe osteoarthritis (≤ 10 days after the intervention), 12 consecutive patients (5 males and 7 females) aged between 50 and 85 years were enrolled for this study. All the patients performed a 2-week thermal multimodal rehabilitation program, which consisted of education and physical rehabilitative measures. Patients had 2-h and half/day session of land-based and hydrokinesitherapy (aquatic therapy) consisted in active and passive joint mobilization, respiratory and functional re-education exercises, gait and balance training, resistance exercise, and power training mainly for the upper limb associated to physical therapy modalities (electrotherapy and low-level laser therapy). An educational program was performed to both patients and families. Both before and after the rehabilitation treatment, patients underwent clinical evaluation, hip flexion/abduction range of motion, and Numeric Pain Rating Scale. Harris Hip Score (HHS) and SF-12 questionnaires (physical—PCS-12—and mental health component—MCS-12) were also administered. After the 2-week thermal spa treatment, hip flexion/abduction improved significantly (p < 0.05), but there was no statistically significant reduction in pain (p = 0.350). The HHS score improved significantly from 62.6 ± 12.8 to 82.15 ± 12.7 (p < 0.05), and the PCS-12 score from 36.37 ± 8.4 to 43.61 ± 8.95 (p < 0.05). There was no adverse event during spa treatment. After total hip arthroplasty, patients who underwent an intensive post-acute multimodal rehabilitation program showed an improvement in motor and functional recovery and a positive impact on quality of life. Therefore, we believe that the

  5. Patients' Expectations Impact Their Satisfaction following Total Hip or Knee Arthroplasty.

    Science.gov (United States)

    Neuprez, Audrey; Delcour, Jean-Pierre; Fatemi, Firouzeh; Gillet, Philippe; Crielaard, Jean-Michel; Bruyère, Olivier; Reginster, Jean-Yves

    2016-01-01

    The objective of this study was to assess the number and magnitude of preoperative expectations and to correlate them with the degree of satisfaction expressed one year after Total Hip Arthroplasty (THA) or Total Knee Arthroplasty (TKA), in patients with severe and painful osteoarthritis (OA). Preoperative expectations (within 20 days prior to surgery) and postoperative satisfaction (one year after the intervention) were measured using the previously validated French version of the Hospital for Special Surgery Hip or Knee Replacement Expectations Survey. Postoperative satisfaction was measured using a specific scale, following the same methodology as that used for the assessment of expectations. Prediction of the satisfaction of the patients was performed using multivariate linear regression modelling. A total of 138 patients (80 THA and 58 TKA) completed the two parts of the study. The expectations score (mean ± SD) (range 0-100) was 72.58 ± 12.63 before THA and 69.10 ± 13.72 before TKA (p = 0.13). The number of expectations expressed was 14.34 ± 1.32 (out of a potential maximum of 18) before THA and 14.70 ± 2.29 (out of a potential maximum of 19) before TKA. After 1 year, THA generated a significantly higher degree of satisfaction compared to TKA (69.70 ± 14.46 v 60.44 ± 17.54, poptimal preoperative interaction between health care providers and patients, to allow patients a chance to foresee a reasonable outcome after TJA.

  6. Physical Activity Behavior of Patients 1 Year After Primary Total Hip Arthroplasty : A Prospective Multicenter Cohort Study

    NARCIS (Netherlands)

    Wagenmakers, Robert; Stevens, Martin; Groothoff, Johan W.; Zijlstra, Wiebren; Bulstra, Sjoerd K.; van Beveren, Jan; van Raaij, Jos J. A. M.; van den Akker-Scheek, Inge

    Background. Besides the important beneficial effects of regular physical activity on general health, some of the musculoskeletal effects of physical activity are of particular interest for older adults after total hip arthroplasty (THA). However, research on physical activity behavior of patients

  7. Postoperative Urinary Catheterization Thresholds of 500 versus 800 ml after Fast-track Total Hip and Knee Arthroplasty

    DEFF Research Database (Denmark)

    Bjerregaard, Lars Stryhn; Hornum, Ulla Marianne; Troldborg, C.

    2016-01-01

    arthroplasty (THA) and total knee arthroplasty (TKA). METHODS: This was a randomized, controlled, open-label trial that included patients greater than or equal to 18 yr who underwent THA or TKA in three Danish, fast-track, orthopedic departments. Consenting patients were eligible if they were cooperative......BACKGROUND: No evidence-based threshold exists for postoperative urinary bladder catheterization. The authors hypothesized that a catheterization threshold of 800 ml was superior to 500 ml in reducing postoperative urinary catheterization and urological complications after fast-track total hip...

  8. Preliminary application of computer-assisted patient-specific acetabular navigational template for total hip arthroplasty in adult single development dysplasia of the hip.

    Science.gov (United States)

    Zhang, Yuan Z; Chen, Bin; Lu, Sheng; Yang, Yong; Zhao, Jian M; Liu, Rui; Li, Yan B; Pei, Guo X

    2011-12-01

    The considerable variation in anatomical abnormalities of hip joints associated with different types of developmental dysplasia of hip (DDH) makes reconstruction in total hip arthroplasty (THA) difficult. It is desirable to create patient-specific designs for THA procedures. In the cases of adult single DDH, an accuracy-improved method has been developed for acetabular cup prosthesis implantation of hip arthroplasty. From October 2007 to November 2008, 22 patients with single DDH (according to the Crowe standard, all dysplasia hips were classified as type I) were scanned with spiral CT pre-operatively. These patients scheduled for THA were randomly assigned to undergo either conventional THA (control group, n = 11) or navigation template implantation (NT group, n = 11). In the NT group, three-dimensional (3D) CT pelvis image data were transferred to a computer workstation and 3D models of the hip were reconstructed using the Mimics software. The 3D models were then processed by the Imageware software. In brief, a template that best fitted the location and shape of the acetabular cup was 'reversely' built from the 3D model, the rotation centre of the pathological hip determined by mirroring that of the healthy site, and a guiding hole in the template was then designed. The navigational templates were manufactured using a rapid prototyping machine. These navigation templates guide acetabular component placement. Based on the predetermined abduction angle 45° and anteversion angle 18°, after 1 year follow-up, the NT group showed significantly smaller differences (1.6° ± 0.4°, 1.9° ± 1.1°) from the predetermined angles than those in the control group (5.8° ± 2.9°, 3.9° ± 2.5°) (P < 0.05). The template designs facilitated accurate placement of acetabular components in dysplasia of acetabulum. The hip's center of rotation in DDH could be established using computer-aided design, which provides a useful method for the accurate

  9. Development and Validation of Perioperative Risk-Adjustment Models for Hip Fracture Repair, Total Hip Arthroplasty, and Total Knee Arthroplasty.

    Science.gov (United States)

    Schilling, Peter L; Bozic, Kevin J

    2016-01-06

    Comparing outcomes across providers requires risk-adjustment models that account for differences in case mix. The burden of data collection from the clinical record can make risk-adjusted outcomes difficult to measure. The purpose of this study was to develop risk-adjustment models for hip fracture repair (HFR), total hip arthroplasty (THA), and total knee arthroplasty (TKA) that weigh adequacy of risk adjustment against data-collection burden. We used data from the American College of Surgeons National Surgical Quality Improvement Program to create derivation cohorts for HFR (n = 7000), THA (n = 17,336), and TKA (n = 28,661). We developed logistic regression models for each procedure using age, sex, American Society of Anesthesiologists (ASA) physical status classification, comorbidities, laboratory values, and vital signs-based comorbidities as covariates, and validated the models with use of data from 2012. The derivation models' C-statistics for mortality were 80%, 81%, 75%, and 92% and for adverse events were 68%, 68%, 60%, and 70% for HFR, THA, TKA, and combined procedure cohorts. Age, sex, and ASA classification accounted for a large share of the explained variation in mortality (50%, 58%, 70%, and 67%) and adverse events (43%, 45%, 46%, and 68%). For THA and TKA, these three variables were nearly as predictive as models utilizing all covariates. HFR model discrimination improved with the addition of comorbidities and laboratory values; among the important covariates were functional status, low albumin, high creatinine, disseminated cancer, dyspnea, and body mass index. Model performance was similar in validation cohorts. Risk-adjustment models using data from health records demonstrated good discrimination and calibration for HFR, THA, and TKA. It is possible to provide adequate risk adjustment using only the most predictive variables commonly available within the clinical record. This finding helps to inform the trade-off between model performance and data

  10. A custom-made guide-wire positioning device for Hip Surface Replacement Arthroplasty: description and first results

    Directory of Open Access Journals (Sweden)

    Clijmans Tim

    2010-07-01

    Full Text Available Abstract Background Hip surface replacement arthroplasty (SRA can be an alternative for total hip arthroplasty. The short and long-term outcome of hip surface replacement arthroplasty mainly relies on the optimal size and position of the femoral component. This can be defined before surgery with pre-operative templating. Reproducing the optimal, templated femoral implant position during surgery relies on guide wire positioning devices in combination with visual inspection and experience of the surgeon. Another method of transferring the templated position into surgery is by navigation or Computer Assisted Surgery (CAS. Though CAS is documented to increase accurate placement particularly in case of normal hip anatomy, it requires bulky equipment that is not readily available in each centre. Methods A custom made neck jig device is presented as well as the results of a pilot study. The device is produced based on data pre-operatively acquired with CT-scan. The position of the guide wire is chosen as the anatomical axis of the femoral neck. Adjustments to the design of the jig are made based on the orthopedic surgeon's recommendations for the drill direction. The SRA jig is designed as a slightly more-than-hemispherical cage to fit the anterior part of the femoral head. The cage is connected to an anterior neck support. Four knifes are attached on the central arch of the cage. A drill guide cylinder is attached to the cage, thus allowing guide wire positioning as pre-operatively planned. Custom made devices were tested in 5 patients scheduled for total hip arthroplasty. The orthopedic surgeons reported the practical aspects of the use of the neck-jig device. The retrieved femoral heads were analyzed to assess the achieved drill place in mm deviation from the predefined location and orientation compared to the predefined orientation. Results The orthopedic surgeons rated the passive stability, full contact with neck portion of the jig and knife

  11. Why still in hospital after fast-track hip and knee arthroplasty?

    DEFF Research Database (Denmark)

    Husted, Henrik; Lunn, Troels H; Troelsen, Anders

    2011-01-01

    Background and purpose Length of stay (LOS) following total hip and knee arthroplasty (THA and TKA) has been reduced to about 3 days in fast-track setups with functional discharge criteria. Earlier studies have identified patient characteristics predicting LOS, but little is known about specific...... reasons for being hospitalized following fast-track THA and TKA. Patients and methods To determine clinical and logistical factors that keep patients in hospital for the first postoperative 24-72 hours, we performed a cohort study of consecutive, unselected patients undergoing unilateral primary THA (n...

  12. Assessment of total hip arthroplasty as a predisposing factor for ischiofemoral impingement

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Adriana L.; Azevedo, Debora C.; Eajazi, Alireza; Palmer, William E.; Bredella, Miriam A. [Massachusetts General Hospital and Harvard Medical School, Division of Musculoskeletal Imaging and Intervention, Boston, MA (United States); Kwon, Young-Min [Massachusetts General Hospital and Harvard Medical School, Department of Orthopedics, Boston, MA (United States); Torriani, Martin [Massachusetts General Hospital and Harvard Medical School, Division of Musculoskeletal Imaging and Intervention, Boston, MA (United States); Massachusetts General Hospital, Division of Musculoskeletal Imaging and Intervention Department of Radiology, Boston, MA (United States)

    2015-12-15

    To examine the effect of total hip arthroplasty (THA) on ischiofemoral (IF) and quadratus femoris (QF) spaces with the hypothesis that THA does not affect ischiofemoral relationships. The study was IRB approved and complied with HIPAA guidelines. We identified consecutive MR examinations (pelvis and/or hip) obtained at our institution in adults (≥18 years old) screened for THA-related complications. Native hips from the same individuals served as controls. We collected medical record data including age, gender, surgical history, and THA designs. Two radiologists independently measured the IF-RAD and IF-MRI (IF space on radiographs and MR imaging, respectively) and QF space (on MR imaging). Groups were compared using ANCOVA controlled for gender. The study group comprised 250 hips (132 subjects; 162 post-THA and 88 native hips). Subjects were aged 59 ± 10 years, with 66 males and 66 females. Comparison of IF-MRI and QF spaces between native and post-THA hips showed no differences (P > 0.12) and IF-RAD was higher in post-THA subjects (P = 0.01). No differences in the IF-MRI and QF spaces were present between native hips and different THA designs (P > 0.4). IF-RAD of metal-on-metal THA was higher than that of native hips (P = 0.01) and trended higher than ceramic-on-polyethylene THA (P = 0.08), with the remaining comparisons showing no significant differences (P > 0.4). Radiographic- and MRI-based measures in patients with standard THA do not show narrowing of IF and QF spaces. (orig.)

  13. Is Cup Positioning Challenged in Hips Previously Treated With Periacetabular Osteotomy?

    DEFF Research Database (Denmark)

    Hartig-Andreasen, Charlotte; Stilling, Maiken; Søballe, Kjeld

    2014-01-01

    After periacetabular osteotomy (PAO), some patients develop osteoarthritis with need of a total hip arthroplasty (THA). We evaluated the outcome of THA following PAO and explored factors associated with inferior cup position and increased polyethylene wear. Follow-up were performed 4 to 10years...... after THA in 34 patients (38 hips) with previous PAO. Computer analysis evaluated cup position and wear rates. No patient had dislocations or revision surgery. Median scores were: Harris hip 96, Oxford hip 38 and WOMAC 78. Mean cup anteversion and abduction angles were 22(o) (range 7°-43°) and 45......° (range 28°-65°). Outliers of cup abduction were associated with persisting dysplasia (CE...

  14. Should total hip arthroplasty be performed acutely in the treatment of acetabular fractures in elderly or used as a salvage procedure only?

    Directory of Open Access Journals (Sweden)

    Katharine Hamlin

    2017-01-01

    Full Text Available Background: Total hip arthroplasty (THA is now an increasingly common procedure for people sustaining acetabular fractures. The incidence of acetabular fractures among the elderly population is increasing, and contemporary treatment aims to avoid the risks of prolonged incumbency associated with poor bone stock for fixation or inability to comply with limited weightbearing in this patient group. The concept of acute hip arthroplasty as a treatment for acetabular fracture is, therefore, becoming more topical and relevant. Our systematic review investigates whether THAs for acetabular fractures should be performed acutely, with a short delay, or as a late procedure for posttraumatic osteoarthritis (PTOA if it develops. Materials and Methods: Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines were followed when undertaking this systematic review. Detailed searches were performed on three different databases, using keywords, such as “acetabular fracture,” “acetabular trauma,” “total hip arthroplasty,” “hip arthroplasty,” and “hip prosthesis.” Studies from 1975 to September 2016 were included in the study. All studies included in the review were independently critically appraised by two of the authors. Results: Forty three studies were included in this review. Only two of them actually compared acute and delayed THAs for acetabular fractures with the rest focusing on one or the other. Results were comparable between acute and late THAs in terms of aseptic loosening, operative time, blood loss, Harris Hip Score, and ability to mobilize postoperatively without aid. Complication rates, however, were much higher in the acute group. Conclusion: Evidence based on this topic is scarce and therefore we have to be cautious about drawing a definitive conclusion. The findings of this systematic review do suggest, however, that acute THAs should be considered in elderly patients, where fixation is not possible, or

  15. A multi-modality tracking, navigation and calibration for a flexible robotic drill system for total hip arthroplasty.

    Science.gov (United States)

    Ahmad Fuad, Ahmad Nazmi Bin; Deep, Kamal; Yao, Wei

    2018-02-01

    This paper presents a novel multi-modality tracking and navigation system that provides a unique capability to guild a flexible drill tip inside the bone with accurate curved tunnelling. As the flexible drill tip cannot be tracked optically inside the bone, this research focuses on developing a hybrid tracking and navigation system for tracking a flexible drill tip by using both optical and kinematic tracking. The tracking information is used to guide the THA (total hip arthroplasty) procedure, providing a real-time virtual model of the flexible drill. The flexible and steerable drill tip system is then tested on total hip arthroplasty followed by evaluation of the positioning and orientation of femoral stem placement by femoral milling. Based on this study, we conclude that the tracking and navigation system is able to guide the flexible drill to mill inside femoral canal. Copyright © 2017 John Wiley & Sons, Ltd.

  16. Total Hip Arthroplasty in an Inveterate Femoral Neck Fracture in a Patient with Congenital Insensitivity to Pain with Anhidrosis.

    Science.gov (United States)

    Dagnino, Augusto; Ursino, Nicola; Ripamonti, Carlo A M; Fiorentini, Carlo E; Scelsi, Michele; D'Ambrosi, Riccardo; Portinaro, Nicola M

    2017-12-01

    Congenital insensitivity to pain with anhidrosis (CIPA) is an extremely rare disorder characterized by autonomic and sensory nerves malfunction with insensitivity to both deep and superficial painful stimuli, inability to sweat and produce tears, and mild to moderate mental retardation with self-mutilating behavior. Related consequences of inveterate musculoskeletal injuries represent a major issue for these patients, since pain cannot act as a protection mechanism. For the same reason, the patients are at risk during postoperative rehabilitation, which should be taken into account when selecting an orthopaedic implant. To our knowledge, only one case of total hip arthroplasty has been reported in the literature to date. A 21-year-old Caucasian male patient affected with CIPA arrived at our attention complaining about a functional limitation of the left hip. No history of trauma was reported. The X-rays showed an inveterate femoral neck fracture with a severe necrosis and resorption of the femoral head. We decided to perform a total hip arthroplasty with a cemented stem and a cemented dual mobility cup. The postoperative course and rehabilitation were satisfactory, with excellent clinical results, measured with the Harris Hip Score at 1 year.

  17. Acetabular cup position and risk of dislocation in primary total hip arthroplasty

    DEFF Research Database (Denmark)

    Seagrave, Kurt G; Troelsen, Anders; Malchau, Henrik

    2017-01-01

    Background and purpose - Hip dislocation is one of the most common complications following total hip arthroplasty (THA). Several factors that affect dislocation have been identified, including acetabular cup positioning. Optimal values for cup inclination and anteversion are debatable. We performed...... a systematic review to describe the different methods for measuring cup placement, target zones for cup positioning, and the association between cup positioning and dislocation following primary THA. Methods - A systematic search of literature in the PubMed database was performed (January and February 2016......) to identify articles that compared acetabular cup positioning and the risk of dislocation. Surgical approach and methods for measurement of cup angles were also considered. Results - 28 articles were determined to be relevant to our research question. Some articles demonstrated that cup positioning influenced...

  18. Revision of migrated pelvic acetabular components in THA with or without vascular involvement

    Directory of Open Access Journals (Sweden)

    Ștefan Cristea

    2016-05-01

    Full Text Available Purpose. The literature describes a high rate of mortality in cases of intrapelvic acetabular component migration, which is a rare but serious complication. Our aim is to establish and propose a treatment protocol according to our results and experience. Material and Methods. We performed eight (8 total hip revisions with acetabular cup migration between 2006 and 2012. A vascular graft was needed in four (4 of these cases. Two (2 cases were revisions after a spacer for infected arthroplasties. The protocol included the following: X-Ray examination (frontal and lateral views, CT angiography, a biological evaluation, a suitable pre-operative plan, at least six (6 units of blood stock, an experienced anesthesiologist, an experienced surgical team that included a vascular surgeon and a versatile arsenal of revision prostheses, bone grafts and vascular grafts. The anterolateral approach was generally used for hip revisions and the retroperitoneal approach in the dorsal decubitus position was used when vascular risk was involved. Results: The acetabular defect was reconstructed using bone grafts and tantalum revision cups in 4 cases, Burch-Schneider cages in 2 cases, a Kerboull ring in 1 case and a cementless oblong cup (Cotyle Espace in 1 case. In 4 cases, an iliac vessel graft procedure was conducted by the vascular surgeon. All patients survived the revision procedures and returned regularly for subsequent check-ups, during which they did not show any septic complications. Conclusions: Intrapelvic acetabular cup migration is a rare but serious complication that can occur after total hip arthroplasty in either septic or aseptic cases. An experienced, multidisciplinary team of surgeons should be involved in planning and conducting such complicated revisions.

  19. Closed Incision Negative Pressure Therapy Versus Standard of Care Surgical Dressing in Revision Total Knee Arthroplasty

    Science.gov (United States)

    2018-06-07

    Surgical Wound; Revision Total Knee Arthroplasty; Wounds and Injuries; Joint Disease; Musculoskeletal Disease; Prosthesis-Related Infections; Infection; Postoperative Complications; Pathologic Processes

  20. What Are Normal Metal Ion Levels After Total Hip Arthroplasty? A Serologic Analysis of Four Bearing Surfaces.

    Science.gov (United States)

    Barlow, Brian T; Ortiz, Philippe A; Boles, John W; Lee, Yuo-Yu; Padgett, Douglas E; Westrich, Geoffrey H

    2017-05-01

    The recent experiences with adverse local tissue reactions have highlighted the need to establish what are normal serum levels of cobalt (Co), chromium (Cr), and titanium (Ti) after hip arthroplasty. Serum Co, Cr, and Ti levels were measured in 80 nonconsecutive patients with well-functioning unilateral total hip arthroplasty and compared among 4 bearing surfaces: ceramic-on-ceramic (CoC); ceramic-on-polyethylene (CoP); metal-on-polyethylene (MoP), and dual mobility (DM). The preoperative and most recent University of California, Los Angeles (UCLA) and Western Ontario and McMaster Universities Arthritis Index (WOMAC) scores were compared among the different bearing surfaces. No significant difference was found among serum Co and Cr levels between the 4 bearing surface groups (P = .0609 and P = .1577). Secondary analysis comparing metal and ceramic femoral heads demonstrated that the metal group (MoP, modular dual mobility (Stryker Orthopedics, Mahwah, NJ) [metal]) had significant higher serum Co levels compared with the ceramic group (CoC, CoP, MDM [ceramic]) (1.05 mg/L ± 1.25 vs 0.59 mg/L ± 0.24; P = .0411). Spearman coefficient identified no correlation between metal ion levels and patient-reported outcome scores. No serum metal ion level differences were found among well-functioning total hip arthroplasty with modern bearing couples. Significantly higher serum Co levels were seen when comparing metal vs ceramic femoral heads in this study and warrants further investigation. Metal ion levels did not correlate with patient-reported outcome measures. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Dislocation of primary total hip arthroplasty and the risk of redislocation.

    LENUS (Irish Health Repository)

    Brennan, Stephen A

    2012-09-01

    6554 primary total hip arthroplasties were reviewed. Risk factors for dislocation were analysed to assess which were important in terms of predicting recurrent instability. The patients risk of having a second dislocation was independently associated with the surgical approach adopted (p = 0.03) and the time to first dislocation from the primary hip replacement (p = 0.002). Early dislocators whose surgery was performed through an anterolateral approach had less recurrence than late dislocators through a posterior or transtrochanteric approach. None of the other risk factors including head size (p = 0.59), modularity (p = 0.54), mechanism of dislocation (p = 0.23), leg length discrepancy (p = 0.69) and acetabular inclination (p = 0.31) were influential. The use of an abduction brace was not useful in preventing a further dislocation with 69.2% of those braced re-dislocating compared to 68.5% who were not braced (p = 0.96).

  2. Femoral component revision with use of impaction bone-grafting and a cemented polished stem.

    NARCIS (Netherlands)

    Schreurs, B.W.; Arts, J.J.C.; Verdonschot, N.J.J.; Buma, P.; Slooff, T.J.J.H.; Gardeniers, J.W.M.

    2005-01-01

    BACKGROUND: The purpose of this study was to evaluate the clinical and radiographic outcomes of revision of the femoral component of a hip arthroplasty with use of an impaction bone-grafting technique and a cemented polished stem. METHODS: Thirty-three consecutive femoral reconstructions that were

  3. A prospective randomised study of periprosthetic femoral bone remodeling using four different bearings in hybrid total hip arthroplasty

    DEFF Research Database (Denmark)

    Zerahn, Bo; Borgwardt, Lotte; Ribel-Madsen, Søren

    2011-01-01

    in all Gruen zones with the largest declines in group D. BMD changes in Gruen zones 1, 2, 3, 6, and 7 correlated with height, and body weight. Advanced age was associated with an increase in bone loss in Gruen zones 1, 2, 3, 6, and 7. A large stem size was associated with a decline in BMD in Gruen zones......Abstract: We performed a study to assess whether different bearing materials have an impact on femoral bone remodeling within the first four years after a hybrid total hip arthroplasty. 205 of 300 patients were available for 4 years follow-up after being randomly allocated to four prosthetic...... 1, 6, and 7.Bone remodeling after total hip arthroplasty may depend on the composition of bearing materials, but age, height, weight, and stem size are also related to changes in BMD....

  4. Rivaroxaban for the prevention of venous thromboembolism after hip or knee arthroplasty. Pooled analysis of four studies

    DEFF Research Database (Denmark)

    Turpie, A G G; Lassen, M R; Eriksson, Birgit

    2011-01-01

    Four phase III studies compared oral rivaroxaban with subcutaneous enoxaparin for the prevention of venous thromboembolism (VTE) after total hip or knee arthroplasty (THA or TKA). A pooled analysis of these studies compared the effect of rivaroxaban with enoxaparin on symptomatic VTE plus all-cau...

  5. Robotics in Arthroplasty: A Comprehensive Review.

    Science.gov (United States)

    Jacofsky, David J; Allen, Mark

    2016-10-01

    Robotic-assisted orthopedic surgery has been available clinically in some form for over 2 decades, claiming to improve total joint arthroplasty by enhancing the surgeon's ability to reproduce alignment and therefore better restore normal kinematics. Various current systems include a robotic arm, robotic-guided cutting jigs, and robotic milling systems with a diversity of different navigation strategies using active, semiactive, or passive control systems. Semiactive systems have become dominant, providing a haptic window through which the surgeon is able to consistently prepare an arthroplasty based on preoperative planning. A review of previous designs and clinical studies demonstrate that these robotic systems decrease variability and increase precision, primarily focusing on component positioning and alignment. Some early clinical results indicate decreased revision rates and improved patient satisfaction with robotic-assisted arthroplasty. The future design objectives include precise planning and even further improved consistent intraoperative execution. Despite this cautious optimism, many still wonder whether robotics will ultimately increase cost and operative time without objectively improving outcomes. Over the long term, every industry that has seen robotic technology be introduced, ultimately has shown an increase in production capacity, improved accuracy and precision, and lower cost. A new generation of robotic systems is now being introduced into the arthroplasty arena, and early results with unicompartmental knee arthroplasty and total hip arthroplasty have demonstrated improved accuracy of placement, improved satisfaction, and reduced complications. Further studies are needed to confirm the cost effectiveness of these technologies. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Good performance of a titanium femoral component in cementless hip arthroplasty in younger patients: 97 arthroplasties followed for 5-11 years

    DEFF Research Database (Denmark)

    Jacobsen, Steffen; Jensen, Frank Krieger; Poulsen, Klaus

    2003-01-01

    We performed 97 uncemented primary total hip arthroplasties in 80 patients having an average age of 50 years. The femoral implant was a titanium stem with a proximal circumferential plasma spray-coating. Three different acetabular components were used: a threaded and partly porous-coated design i...... titanium femoral component with a circumferential porous coating performed well in these patients, most of whom were young. As reported previously, aseptic loosening of threaded acetabular components was common....

  7. Variation in Use of Blood Transfusion in Primary Total Hip and Knee Arthroplasties.

    Science.gov (United States)

    Menendez, Mariano E; Lu, Na; Huybrechts, Krista F; Ring, David; Barnes, C Lowry; Ladha, Karim; Bateman, Brian T

    2016-12-01

    There is growing clinical and policy emphasis on minimizing transfusion use in elective joint arthroplasty, but little is known about the degree to which transfusion rates vary across US hospitals. This study aimed to assess hospital-level variation in use of allogeneic blood transfusion in patients undergoing elective joint arthroplasty and to characterize the extent to which variability is attributable to differences in patient and hospital characteristics. The study population included 228,316 patients undergoing total knee arthroplasty (TKA) at 922 hospitals and 88,081 patients undergoing total hip arthroplasty (THA) at 606 hospitals from January 1, 2009 to December 31, 2011 in the Nationwide Inpatient Sample database, a 20% stratified sample of US community hospitals. The median hospital transfusion rates were 11.0% (interquartile range, 3.5%-18.5%) in TKA and 15.9% (interquartile range, 5.4%-26.2%) in THA. After fully adjusting for patient- and hospital-related factors using mixed-effects logistic regression models, the average predicted probability of blood transfusion use in TKA was 6.3%, with 95% of the hospitals having a predicted probability between 0.37% and 55%. For THA, the average predicted probability of blood transfusion use was 9.5%, with 95% of the hospitals having a predicted probability between 0.57% and 66%. Hospital transfusion rates were inversely associated with hospital procedure volume and directly associated with length of stay. The use of blood transfusion in elective joint arthroplasty varied widely across US hospitals, largely independent of patient case-mix and hospital characteristics. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Periprosthetic femoral fracture within two years after total hip replacement:

    DEFF Research Database (Denmark)

    Thien, T. M.; Chatziagorou, G.; Garellick, G.

    2014-01-01

    BACKGROUND: We used the Nordic Arthroplasty Register Association database to evaluate whether age, sex, preoperative diagnosis, fixation, and implant design influence the risk of revision arthroplasty due to periprosthetic fracture within two years from operation of a primary total hip replacement....... METHODS: Included in the study were 325,730 cemented femoral stems and 111,899 uncemented femoral stems inserted from 1995 to 2009. Seven frequently used stems (two cemented stems [Exeter and Lubinus SP II] and five uncemented stems [Bi-Metric, Corail, CLS Spotorno, ABG I, and ABG II]) were specifically...... studied. RESULTS: The incidence of revision at two years was low: 0.47% for uncemented stems and 0.07% for cemented stems. Uncemented stems were much more likely to have this complication (relative risk, 8.72 [95% confidence interval, 7.37 to 10.32]; p

  9. Total hip arthroplasty in patients with neuromuscular imbalance.

    Science.gov (United States)

    Konan, S; Duncan, C P

    2018-01-01

    Patients with neuromuscular imbalance who require total hip arthroplasty (THA) present particular technical problems due to altered anatomy, abnormal bone stock, muscular imbalance and problems of rehabilitation. In this systematic review, we studied articles dealing with THA in patients with neuromuscular imbalance, published before April 2017. We recorded the demographics of the patients and the type of neuromuscular pathology, the indication for surgery, surgical approach, concomitant soft-tissue releases, the type of implant and bearing, pain and functional outcome as well as complications and survival. Recent advances in THA technology allow for successful outcomes in these patients. Our review suggests excellent benefits for pain relief and good functional outcome might be expected with a modest risk of complication. Cite this article: Bone Joint J 2018;100-B(1 Supple A):17-21. ©2018 The British Editorial Society of Bone & Joint Surgery.

  10. [A method to avoid lengthening lower limbs after total hip arthroplasty in patients with congenital short femoral neck].

    Science.gov (United States)

    Chen, Tao; Shang, Xifu; He, Rui; Hu, Fei; Ge, Chang

    2012-03-01

    To investigate the method to avoid lengthening lower limbs after total hip arthroplasty in patients with congenital short femoral neck. The clinical data were analyzed retrospectively from 38 patients undergoing unilateral total hip arthroplasty between April 2005 and December 2010. There were 26 males and 12 females, aged 45-78 years (mean, 62.3 years). Among these cases, there were 11 cases of avascular necrosis of the femoral head, 17 cases of hip osteoarthritis, and 10 cases of femoral neck fracture. Before operation, 29 cases had leg length discrepancy; and the shortened length of the legs was 10-24 mm with an average of 14.5 mm by clinical measurement, and was 11-25 mm with an average of 14.7 mm by X-ray film measurement. The Harris score before operation was 44.0 +/- 3.6. At 1 day after operation, 3 cases had legs lengthening by clinical and X-ray film measurement; limb length difference less than 10 mm was regarded as equal limb length in the other 35 patients (92.1%). All incisions healed by first intention, and no complication of infection or lower limb deep venous thrombosis occurred. In 3 patients who had legs lengthening, 1 patient had abnormal gait and slight limping after increasing heel pad because the lower limb was lengthened by 16 mm, and 2 patients had slight limping. The other patients could walk normally and achieved pain relief of hip. Thirty-six patients were followed up 12-68 months (mean, 43.8 months). The Harris score was 86.7 +/- 2.3 after 6 months, showing significant difference (t = 3.260, P = 0.031) when compared with that before operation. The X-ray films showed no prosthetic loosening or subsidence. For patients with congenital short femoral neck during total hip arthroplasty, the surgeons should pay attention to osteotomy plane determination, limb length measurement, and use of the prosthesis with collar to avoid the lengthening lower limbs.

  11. [Ceramic-on-ceramic bearings in total hip arthroplasty (THA)].

    Science.gov (United States)

    Sentürk, U; Perka, C

    2015-04-01

    The main reason for total hip arthroplasty (THA) revision is the wear-related aseptic loosening. Younger and active patients after total joint replacement create high demands, in particular, on the bearings. The progress, especially for alumina ceramic-on-ceramic bearings and mixed ceramics have solved many problems of the past and lead to good in vitro results. Modern ceramics (alumina or mixed ceramics containing alumina) are extremely hard, scratch-resistant, biocompatible, offer a low coefficient of friction, superior lubrication and have the lowest wear rates in comparison to all other bearings in THA. The disadvantage of ceramic is the risk of material failure, i.e., of ceramic fracture. The new generation of mixed ceramics (delta ceramic), has reduced the risk of head fractures to 0.03-0.05 %, but the risk for liner fractures remains unchanged at about 0.02 %. Assuming a non-impinging component implantation, ceramic-on-ceramic bearings have substantial advantages over all other bearings in THA. Due to the superior hardness, ceramic bearings produce less third body wear and are virtually impervious to damage from instruments during the implantation process. A specific complication for ceramic-on-ceramic bearings is "squeaking". The high rate of reported squeaking (0.45 to 10.7 %) highlights the importance of precise implant positioning and the stem and patient selection. With precise implant positioning this problem is rare with many implant designs and without clinical relevance. The improved tribology and the presumable resulting implant longevity make ceramic-on-ceramic the bearing of choice for young and active patients. Georg Thieme Verlag KG Stuttgart · New York.

  12. Countrywise results of total hip replacement An analysis of 438,733 hips based on the Nordic Arthroplasty Register Association database

    DEFF Research Database (Denmark)

    Makela, K. T.; Matilainen, M.; Pulkkinen, P.

    2014-01-01

    Background and purpose An earlier Nordic Arthroplasty Register Association (NARA) report on 280,201 total hip replacements (THRs) based on data from 1995-2006, from Sweden, Norway, and Denmark, was published in 2009. The present study assessed THR survival according to country, based on the NARA.......36-0.98) year of follow-up. Interpretation The differences in THR survival rates were considerable, with inferior results in Finland. Brand-level comparison of THRs in Nordic countries will be required....

  13. Transfusion-related mortality after primary hip arthroplasty - an analysis of mechanisms and confounders

    DEFF Research Database (Denmark)

    Jans, O; Kehlet, H; Johansson, P I

    2012-01-01

    Background and Objectives Bleeding and postoperative anaemia after total hip arthroplasty (THA) may trigger transfusion of red blood cells (RBC). However, large observational studies have reported associations between RBC transfusion and increased postoperative morbidity and mortality. As major...... bleeding or severe postoperative anaemia is intrinsically linked with RBC transfusion, direct causality between transfusion and adverse outcomes remains unclear. This study aimed to identify possible relations between RBC transfusion, severe bleeding or anaemia and mortality in all patients who died...

  14. Histologic evaluation of the bone-ceramic interface of an alumina ceramic cup arthroplasty retrieved after 25 years in vivo

    Directory of Open Access Journals (Sweden)

    Fuminori Higuchi, MD

    2016-09-01

    Full Text Available A 47-year-old man underwent ceramic cup arthroplasty when he was 22 years old. Revision total hip arthroplasty was performed 25 years later because of limited range of motion without implant loosening. Histologic examination revealed that the femoral head and ceramic implant were well fixed through a thin fibrous membrane. The energy-dispersive X-ray analysis indicated that calcium and phosphorus were detected in the same peak pattern as cancellous bone in the bone-ceramic interface.

  15. Similar range of motion and function after resurfacing large-head or standard total hip arthroplasty

    DEFF Research Database (Denmark)

    Penny, Jeannette Østergaard; Ovesen, Ole; Varmarken, Jens-Erik

    2013-01-01

    BACKGROUND AND PURPOSE: Large-size hip articulations may improve range of motion (ROM) and function compared to a 28-mm THA, and the low risk of dislocation allows the patients more activity postoperatively. On the other hand, the greater extent of surgery for resurfacing hip arthroplasty (RHA......° (35), 232° (36), and 225° (30) respectively, but the differences were not statistically significant. The 3 groups were similar regarding Harris hip score, UCLA activity score, step rate, and sick leave. INTERPRETATION: Head size had no influence on range of motion. The lack of restriction allowed...... for large articulations did not improve the clinical and patient-perceived outcomes. The more extensive surgical procedure of RHA did not impair the rehabilitation. This project is registered at ClinicalTrials.gov under # NCT01113762....

  16. Predictors of pain and physical function at 3 and 12 months after total hip arthroplasty

    DEFF Research Database (Denmark)

    Plews, Sarah; Løvlund Nielsen, Randi; Overgaard, Søren

    Background: Few studies have combined preoperative patient-reported and objective outcome measures to predict outcomes after total hip arthroplasty (THA). Purpose / Aim of Study: to identify predictors of outcome 3 and 12 months after THA Materials and Methods: A cohort of 107 consecutive patients...... with primary hip osteoarthritis responded to Hip dysfunction and Osteoarthritis Outcome Score (HOOS) questionnaires prior to and 3 and 12 months after THA. Preoperative pain intensity; joint space width (JSW), age, gender, and body mass index (BMI) were used to predict changes in pain and physical function....... Conclusions: Preoperative pain predicted changes in pain and physical function up to one year after THA. Such knowledge should be taken into consideration, when assessing OA patients prior to surgery. This study provides useful insight for clinicians, regarding the overall improvement patients can expect...

  17. Effects of Prosthesis Stem Tapers on Stress Distribution of Cemented Hip Arthroplasty

    International Nuclear Information System (INIS)

    Abdullah, Abdul Halim; Nor, Mohd Asri Mohd; Saman, Alias Mohd; Tamin, Mohd Nasir; Kadir, Mohammed Rafiq Abdul

    2010-01-01

    Aseptic loosening effects are critical issues in encouraging long term stability of cemented hip arthroplasty. Stress shielding is believed to be an important factor that contributes to the aseptic loosening problems. The numerous changes in the prosthesis stem design are intended to minimize the stress shielding and aseptic loosening problems and to improve the long term performance of the implants. In this study, the stress distribution in cemented hip arthroplasty is established using finite element method. The taper of the prosthesis is designed to be 3 deg. at anterior/posterior, 3 deg. at medial/lateral and 10 deg. from wide lateral to narrow medial. Major muscle loads and contact forces are simulated for walking (toe-off phase) and stair climbing load cases. Effects of prosthesis stem tapers on the resulting stress distribution are investigated. Results show that compressive stress dominates in the medial plane while tensile stress in the lateral plane of the femur. The corresponding stress levels of intact femur for walking and stair-climbing load cases are 22 and 29 MPa, respectively. The magnitude of Tresca stress for the THA femur in stair-climbing load case remains higher in the region of 85 MPa while the walking load case induces around 40 MPa. The stress range in the straight and single taper stem prosthesis is lower than 260 MPa, while localized Tresca stress is in the order of the yield strength of Ti-6Al-4V alloy for double and triple taper stem design.

  18. Should All Patients Be Included in Alternative Payment Models for Primary Total Hip Arthroplasty and Total Knee Arthroplasty?

    Science.gov (United States)

    Rozell, Joshua C; Courtney, Paul M; Dattilo, Jonathan R; Wu, Chia H; Lee, Gwo-Chin

    2016-09-01

    Alternative payment models in total joint replacement incentivize cost effective health care delivery and reward reductions in length of stay (LOS), complications, and readmissions. If not adjusted for patient comorbidities, they may encourage restrictive access to health care. We prospectively evaluated 802 consecutive primary total hip arthroplasty and total knee arthroplasty patients evaluating comorbidities associated with increased LOS and readmissions. During this 9-month period, 115 patients (14.3%) required hospitalization >3 days and 16 (1.99%) were readmitted within 90 days. Univariate analysis demonstrated that preoperative narcotic use, heart failure, stroke, chronic kidney disease (CKD), chronic obstructive pulmonary disease (COPD), and liver disease were more likely to require hospitalization >3 days. In multivariate analysis, CKD and COPD were independent risk factors for LOS >3 days. A Charlson comorbidity index >5 points was associated with increased LOS and readmissions. Patients with CKD, COPD, and Charlson comorbidity index >5 points should not be included in alternative payment model for THA and TKA. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Use of a constrained tripolar acetabular liner to treat intraoperative instability and postoperative dislocation after total hip arthroplasty: a review of our experience.

    Science.gov (United States)

    Callaghan, John J; O'Rourke, Michael R; Goetz, Devon D; Lewallen, David G; Johnston, Richard C; Capello, William N

    2004-12-01

    Constrained acetabular components have been used to treat certain cases of intraoperative instability and postoperative dislocation after total hip arthroplasty. We report our experience with a tripolar constrained component used in these situations since 1988. The outcomes of the cases where this component was used were analyzed for component failure, component loosening, and osteolysis. At average 10-year followup, for cases treated for intraoperative instability (2 cases) or postoperative dislocation (4 cases), the component failure rate was 6% (6 of 101 hips in 5 patients). For cases where the constrained liner was cemented into a fixed cementless acetabular shell, the failure rate was 7% (2 of 31 hips in 2 patients) at 3.9-year average followup. Use of a constrained liner was not associated with an increased osteolysis or aseptic loosening rate. This tripolar constrained acetabular liner provided total hip arthroplasty construct stability in most cases in which it was used for intraoperative instability or postoperative dislocation.

  20. National Incidence of Patient Safety Indicators in the Total Hip Arthroplasty Population.

    Science.gov (United States)

    Tanenbaum, Joseph E; Knapik, Derrick M; Wera, Glenn D; Fitzgerald, Steven J

    2017-09-01

    The Centers for Medicare & Medicaid Services use the incidence of patient safety indicators (PSIs) to determine health care value and hospital reimbursement. The national incidence of PSI has not been quantified in the total hip arthroplasty (THA) population, and it is unknown if patient insurance status is associated with PSI incidence after THA. All patients in the Nationwide Inpatient Sample (NIS) who underwent THA in 2013 were identified using the International Classification of Diseases, Ninth Revision, Clinical Modification codes. The incidence of PSI was determined using the International Classification of Diseases, Ninth Revision, diagnosis code algorithms published by the Centers for Medicare & Medicaid Services and the Agency for Healthcare Research and Quality. The association of insurance status and the incidence of PSI during the inpatient episode was determined by comparing privately insured and Medicare patients with Medicaid/self-pay patients using a logistic regression model that controlled for patient demographics, patient comorbidities, and hospital characteristics. In 2013, the NIS included 68,644 hospitalizations with primary THA performed during the inpatient episode. During this period, 429 surgically relevant PSI were recorded in the NIS. The estimated national incidence rate of PSI after primary THA was 0.63%. In our secondary analysis, the privately insured cohort had significantly lower odds of experiencing one or more PSIs relative to the Medicaid/self-pay cohort (odds ratio, 0.47; 95% confidence interval, 0.29-0.76). The national incidence of PSI among THA patients is relatively low. However, primary insurance status is associated with the incidence of one or more PSIs after THA. As value-based payment becomes more widely adopted in the United States, quality benchmarks and penalty thresholds need to account for these differences in risk-adjustment models to promote and maintain access to care in the underinsured population. Copyright

  1. Ceramic on ceramic arthroplasty of the hip: new materials confirm appropriate use in young patients.

    Science.gov (United States)

    Sentuerk, U; von Roth, P; Perka, C

    2016-01-01

    The leading indication for revision total hip arthroplasty (THA) remains aseptic loosening owing to wear. The younger, more active patients currently undergoing THA present unprecedented demands on the bearings. Ceramic-on-ceramic (CoC) bearings have consistently shown the lowest rates of wear. The recent advances, especially involving alumina/zirconia composite ceramic, have led to substantial improvements and good results in vitro. Alumina/zirconia composite ceramics are extremely hard, scratch resistant and biocompatible. They offer a low co-efficient of friction and superior lubrication and lower rates of wear compared with other bearings. The major disadvantage is the risk of fracture of the ceramic. The new composite ceramic has reduced the risk of fracture of the femoral head to 0.002%. The risk of fracture of the liner is slightly higher (0.02%). Assuming that the components are introduced without impingement, CoC bearings have major advantages over other bearings. Owing to the superior hardness, they produce less third body wear and are less vulnerable to intra-operative damage. The improved tribology means that CoC bearings are an excellent choice for young, active patients requiring THA. ©2016 The British Editorial Society of Bone & Joint Surgery.

  2. Reliability of using DXA around RTHAs. Bone Mineral Density of the femoral neck in resurfacing hip arthroplasty. Precision biased by region of interest and rotation of the hip

    DEFF Research Database (Denmark)

    Penny, Jeannette Østergaard; Varmarken, Jens-Erik; Ovesen, Ole

    2009-01-01

      Introduction:  Resurfacing Total Hip Arthroplasty (RTHA) may preserve the femoral neck bone-stock post-operatively. Bone Mineral Density (BMD), could theoretically be affected by the hip-position, and bias longitudinal studies. We aimed to investigate BMD precision dependency on type of ROI...... the hip was rotated in increments of 15° and 30°, the mean CVs rose to 7.2%, 7.3% and 11.8%.  Rotation affected the precision most in the model that divided the neck in 6 sub regions, predominantly in the lateral and distal regions. For larger-region models, some rotation could be allowed without...

  3. Femoral component revision with use of impaction bone-grafting and a cemented polished stem. Surgical technique.

    NARCIS (Netherlands)

    Schreurs, B.W.; Arts, J.J.C.; Verdonschot, N.J.J.; Buma, P.; Slooff, T.J.J.H.; Gardeniers, J.W.M.

    2006-01-01

    BACKGROUND: The purpose of this study was to evaluate the clinical and radiographic outcomes of revision of the femoral component of a hip arthroplasty with use of an impaction bone-grafting technique and a cemented polished stem. METHODS: Thirty-three consecutive femoral reconstructions that were

  4. Greater Trochanteric Fixation Using a Cable System for Partial Hip Arthroplasty: A Clinical and Finite Element Analysis

    Science.gov (United States)

    Ozan, Fırat; Koyuncu, Şemmi; Pekedis, Mahmut; Altay, Taşkın; Yıldız, Hasan; Toker, Gökhan

    2014-01-01

    The aim of the study was to investigate the efficacy of greater trochanteric fixation using a multifilament cable to ensure abductor lever arm continuity in patients with a proximal femoral fracture undergoing partial hip arthroplasty. Mean age of the patients (12 men, 20 women) was 84.12 years. Mean follow-up was 13.06 months. Fixation of the dislocated greater trochanter with or without a cable following load application was assessed by finite element analysis (FEA). Radiological evaluation was based on the distance between the fracture and the union site. Harris hip score was used to evaluate final results: outcomes were excellent in 7 patients (21.8%), good in 17 patients (53.1%), average in 5 patients (15.6%), and poor in 1 patient (9.3%). Mean abduction angle was 20.21°. Union was achieved in 14 patients (43.7%), fibrous union in 12 (37.5%), and no union in 6 (18.7%). FEA showed that the maximum total displacement of the greater trochanter decreased when the fractured bone was fixed with a cable. As the force applied to the cable increased, the displacement of the fractured trochanter decreased. This technique ensures continuity of the abductor lever arm in patients with a proximal femoral fracture who are undergoing partial hip arthroplasty surgery. PMID:25177703

  5. Fall-related admissions after fast-track total hip and knee arthroplasty - cause of concern or consequence of success?

    DEFF Research Database (Denmark)

    Jørgensen, Christoffer Calov; Kehlet, Henrik; Hip, Lundbeck Foundation Centre for Fast-track

    2013-01-01

    Total hip (THA) and knee arthroplasty (TKA) are common procedures in elderly persons, who are at potential increased risk of postoperative fall due to loss of muscle strength and impaired balance. Fast-track surgery with early mobilization and opioid-sparing analgesia have improved outcomes after...

  6. Preoperative or postoperative self-efficacy : Which is a better predictor of outcome after total hip or knee arthroplasty?

    NARCIS (Netherlands)

    van den Akker-Scheek, Inge; Stevens, Martin; Groothoff, Johan W.; Bulstra, Sjoerd K.; Zijlstra, Wiebren

    Objective: Self-efficacy is considered an important determinant of outcome after total hip or knee arthroplasty. Aim of this study is to evaluate the contributions of preoperative and short-term postoperative self-efficacy in predicting long-term outcome. Methods: Self-efficacy was determined in 103

  7. Irrigation and Debridement with Component Retention for Acute Infection After Hip Arthroplasty: Improved Results with Contemporary Management.

    Science.gov (United States)

    Bryan, Andrew J; Abdel, Matthew P; Sanders, Thomas L; Fitzgerald, Steven F; Hanssen, Arlen D; Berry, Daniel J

    2017-12-06

    There are conflicting data on the results of irrigation and debridement with component retention in patients with acute periprosthetic hip infections. The goals of this study were to examine contemporary results of irrigation and debridement with component retention for acute infection after primary hip arthroplasty and to identify host, organism, antibiotic, or implant factors that predict success or failure. Ninety hips (57 total hip arthroplasties and 33 hemiarthroplasties) were diagnosed with acute periprosthetic hip infection (using strict criteria) and were treated with irrigation and debridement and component retention between 2000 and 2012. The mean follow-up was 6 years. Patients were stratified on the basis of McPherson criteria. Hips were managed with irrigation and debridement and retention of well-fixed implants with modular head and liner exchange (70%) or irrigation and debridement alone (30%). Seventy-seven percent of patients were treated with chronic antibiotic suppression. Failure was defined as failure to eradicate infection, characterized by a wound fistula, drainage, intolerable pain, or infection recurrence caused by the same organism strain; subsequent removal of any component for infection; unplanned second wound debridement for ongoing deep infection; and/or occurrence of periprosthetic joint infection-related mortality. Treatment failure occurred in 17% (15 of 90 hips), with component removal secondary to recurrent infection in 10% (9 of 90 hips). Treatment failure occurred in 15% (10 of 66 hips) after early postoperative infection and 21% (5 of 24 hips) after acute hematogenous infection (p = 0.7). Patients with McPherson host grade A had a treatment failure rate of 8%, compared with 16% (p = 0.04) in host grade B and 44% in host grade C (p = 0.006). Most treatment failures (12 of 15 failures) occurred within the initial 6 weeks of treatment; failures subsequent to 6 weeks occurred in 3% of those treated with chronic antibiotic

  8. Prothrombin fragment 1+2 in urine as an indicator of sustained coagulation activation after total hip arthroplasty

    DEFF Research Database (Denmark)

    Borris, L.C.; Breindahl, M.; Ryge, C.

    2007-01-01

    Purpose: Prothrombin fragment 1 + 2 measured in spot urine (uF1 + 2) is an indicator of thrombin generation. We examined whether measured levels of uF1 + 2 can be used to differentiate between patients who do and do not acquire sustained coagulation activation after total hip arthroplasty (THA...

  9. Hospital volume and the risk of revision in Oxford unicompartmental knee arthroplasty in the Nordic countries -an observational study of 14,496 cases

    DEFF Research Database (Denmark)

    Badawy, Mona; Fenstad, Anne M.; Bartz-Johannessen, Christoffer A.

    2017-01-01

    Background: High procedure volume and dedication to unicompartmental knee arthroplasty (UKA) has been suggested to improve revision rates. This study aimed to quantify the annual hospital volume effect on revision risk in Oxfordu? nicompartmental knee arthroplasty in the Nordic countries. Methods......). The outcome was revision risk after 2 and 10 years calculated using Kaplan Meier method. Multivariate Cox regression analysis was used to assess the Hazard Ratio (HR) of any revision due to specific reasons with 95% confidence intervals (CI). Results: The implant survival was 80% at 10 years in the volume...

  10. Clinical outcome after treatment of infected primary total knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik; Jensen, Tim Toftgaard

    2002-01-01

    Twenty-six consecutive cases of infected primary total knee arthroplasties were treated at our institution from 1989 through 2000. Eleven patients had debridement and irrigation performed within 2 months of index arthroplasty or hematogenous spread; only one infection was eradicated. Twenty......-five patients had their prostheses removed; 17 had two-stage revision arthroplasty, following which infection was eradicated in 15; one had a permanent spacer, 7 had arthrodesis (following failed revision arthroplasty in one) and 2 had a femur amputation (following failed revision arthroplasty in one) at follow......-up of mean 24 months. Infections were cured equally well with revision arthroplasty and arthrodesis. Among the 15 patients who ended up with revision arthroplasty, 11 had a better range of motion compared to the index arthroplasty, but 8 had daily pain. We present our treatment protocol, which eradicated 15...

  11. Cystic lesion around the hip joint

    Science.gov (United States)

    Yukata, Kiminori; Nakai, Sho; Goto, Tomohiro; Ikeda, Yuichi; Shimaoka, Yasunori; Yamanaka, Issei; Sairyo, Koichi; Hamawaki, Jun-ichi

    2015-01-01

    This article presents a narrative review of cystic lesions around the hip and primarily consists of 5 sections: Radiological examination, prevalence, pathogenesis, symptoms, and treatment. Cystic lesions around the hip are usually asymptomatic but may be observed incidentally on imaging examinations, such as computed tomography and magnetic resonance imaging. Some cysts may enlarge because of various pathological factors, such as trauma, osteoarthritis, rheumatoid arthritis, or total hip arthroplasty (THA), and may become symptomatic because of compression of surrounding structures, including the femoral, obturator, or sciatic nerves, external iliac or common femoral artery, femoral or external iliac vein, sigmoid colon, cecum, small bowel, ureters, and bladder. Treatment for symptomatic cystic lesions around the hip joint includes rest, nonsteroidal anti-inflammatory drug administration, needle aspiration, and surgical excision. Furthermore, when these cysts are associated with osteoarthritis, rheumatoid arthritis, and THA, primary or revision THA surgery will be necessary concurrent with cyst excision. Knowledge of the characteristic clinical appearance of cystic masses around the hip will be useful for determining specific diagnoses and treatments. PMID:26495246

  12. [APPLICATION OF COMPUTER-ASSISTED TECHNOLOGY IN ANALYSIS OF REVISION REASON OF UNICOMPARTMENTAL KNEE ARTHROPLASTY].

    Science.gov (United States)

    Jia, Di; Li, Yanlin; Wang, Guoliang; Gao, Huanyu; Yu, Yang

    2016-01-01

    To conclude the revision reason of unicompartmental knee arthroplasty (UKA) using computer-assisted technology so as to provide reference for reducing the revision incidence and improving the level of surgical technique and rehabilitation. The relevant literature on analyzing revision reason of UKA using computer-assisted technology in recent years was extensively reviewed. The revision reasons by computer-assisted technology are fracture of the medial tibial plateau, progressive osteoarthritis of reserved compartment, dislocation of mobile bearing, prosthesis loosening, polyethylene wear, and unexplained persistent pain. Computer-assisted technology can be used to analyze the revision reason of UKA and guide the best operating method and rehabilitation scheme by simulating the operative process and knee joint activities.

  13. Effectiveness of accelerated perioperative care and rehabilitation intervention compared to current intervention after hip and knee arthroplasty. A before-after trial of 247 patients with a 3-month follow-up

    Directory of Open Access Journals (Sweden)

    Hansen Torben B

    2008-04-01

    Full Text Available Abstract Background In Denmark, approximately 12,000 hip and knee arthroplasties were performed in 2006, and the hospital costs were close to US$ 110,000,000. In a randomized clinical trial, we have recently demonstrated the efficacy of accelerated perioperative care and rehabilitation intervention after hip and knee arthroplasty compared to current intervention under ideal circumstances. We do not, however, know whether these results could be reached under usual circumstances of healthcare practice. We therefore investigated whether length of stay after implementation of accelerated perioperative care and rehabilitation after hip and knee arthroplasty could be reduced in a normal healthcare setting, and how the achieved results matched those observed during the randomized clinical trial. Methods An effectiveness study as a before-after trial was undertaken in which all elective primary total hip and total knee arthroplasty patients were divided into a before-implementation group receiving the current perioperative procedure, and an after-implementation group receiving the new accelerated perioperative care and rehabilitation procedures as provided by a new multi-disciplinary organization. We used the Breakthrough Series Collaborative Model for implementation. The primary outcome measure was in hospital length of stay (LOS, and the secondary outcome measure was adverse effects within 3 months postoperatively. Results We included a total of 247 patients. Mean LOS was significantly (P Conclusion Accelerated perioperative care and rehabilitation intervention after hip and knee arthroplasty was successfully and effectively implemented. Results obtained during usual hospital circumstances matched the results achieved under ideal circumstances in this group of patients.

  14. Radiological aspects of Arthroplasties

    International Nuclear Information System (INIS)

    Garcia, Sara Eugenia; Barragan, John Henry; Narvaez, Jorge Andres

    2008-01-01

    The development of new surgical techniques, of new prosthetic materials, and the increase in life expectancy with greater coverage of health services has ugmented the performance of hip replacements in our country. The radiologist should be familiar with the different surgical techniques and prosthetic devices, the evaluation of its components and associated complications. The most frequently performed arthroplasties are: shoulder, elbow, hip and knee replacement. This article reviews the most frequent prosthetic devices used, the radiological aspects of arthroplasties and their most common complications.

  15. Factors influencing initial cup stability in total hip arthroplasty.

    Science.gov (United States)

    Amirouche, Farid; Solitro, Giovanni; Broviak, Stefanie; Gonzalez, Mark; Goldstein, Wayne; Barmada, Riad

    2014-12-01

    One of the main goals in total hip replacement is to preserve the integrity of the hip kinematics, by well positioning the cup and to make sure its initial stability is congruent and attained. Achieving the latter is not trivial. A finite element model of the cup-bone interface simulating a realistic insertion and analysis of different scenarios of cup penetration, insertion, under-reaming and loading is investigated to determine certain measurable factors sensitivity to stress-strain outcome. The insertion force during hammering and its relation to the cup penetration during implantation is also investigated with the goal of determining the initial stability of the acetabular cup during total hip arthroplasty. The mathematical model was run in various configurations to simulate 1 and 2mm of under-reaming at various imposed insertion distances to mimic hammering and insertion of cup insertion into the pelvis. Surface contact and micromotion at the cup-bone interface were evaluated after simulated cup insertion and post-operative loading conditions. The results suggest a direct correlation between under-reaming and insertion force used to insert the acetabular cup on the micromotion and fixation at the cup-bone interface. While increased under-reaming and insertion force result in an increase amount of stability at the interface, approximately the same percentage of surface contact and micromotion reduction can be achieved with less insertion force. We need to exercise caution to determine the optimal configuration which achieves a good conformity without approaching the yield strength for bone. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Effectiveness of rehabilitation after a total hip arthroplasty : A protocol for an observational study for the comparison of usual care in the Netherlands versus Germany

    NARCIS (Netherlands)

    Seeber, Gesine H; Wijnen, Annet; Lazovic, Djordje; Bulstra, Sjoerd K; Dietz, Günter; van Lingen, Christiaan P; Stevens, Martin

    Introduction Osteoarthritis is the most common joint disorder worldwide. Total hip arthroplasty (THA) is considered one of the most effective treatments for end-stage hip osteoarthritis. The number of THAs is expected to increase dramatically in the coming decades. Usual postoperative rehabilitation

  17. Oxidized zirconium head on crosslinked polyethylene liner in total hip arthroplasty: a 7- to 12-year in vivo comparative wear study.

    Science.gov (United States)

    Karidakis, George K; Karachalios, Theofilos

    2015-12-01

    Osteolysis resulting from wear debris production from the bearing surfaces is a major factor limiting long-term survival of hip implants. Oxidized zirconium head on crosslinked polyethylene (XLPE) is a modern bearing coupling. However, midterm in vivo wear data of this coupling are not known. The purpose of this study was to investigate in vivo whether the combination of an oxidized zirconium femoral head on XLPE produces less wear than a ceramic head on XLPE or a ceramic head on conventional polyethylene (CPE) couplings and whether any of these bearing combinations results in higher hip scores. Between 2003 and 2007, we performed 356 total hip arthroplasties in 288 patients; of those, 199 (69.1%) patients (199 hips) were enrolled in what began as a randomized trial. Unfortunately, after the 57(th) patient, the randomization process was halted because of patients' preference for the oxidized zirconium bearing instead of the ceramic after (as they were informed by the consent form), and after that, alternate allocation to the study groups was performed. Hips were allocated into four groups: in Group A, a 28-mm ceramic head on CPE was used; in Group B, a 28-mm ceramic head on XLPE; in Group C, a 28-mm Oxinium head on XLPE; and in Group D, a 32-mm Oxinium head on XLPE. The authors prospectively collected in vivo wear data (linear wear, linear wear rate, volumetric wear, and volumetric wear rate) using PolyWare software. Preoperative and postoperative clinical data, including Harris and Oxford hip scores, were also collected at regular intervals. Of those patients enrolled, 188 (95%) were available for final followup at a minimum of 7 years (mean, 9 years; range, 7-12 years). All bearing surfaces showed a varying high bedding-in effect (plastic deformation of the liner) up to the second postoperative year. At 5 years both oxidized zirconium on XLPE groups showed lower (p zirconium on XLPE groups also showed lower (p zirconium groups were compared, no differences were

  18. Extensively coated revision stems in proximally deficient femur: Early results in 15 patients

    Directory of Open Access Journals (Sweden)

    Marya SKS

    2008-01-01

    Full Text Available Background: Hip replacement following failed internal fixation (dynamic hip screw for intertrochanteric fractures or previous hip arthroplasty presents a major surgical challenge. Proximal fitting revision stems do not achieve adequate fixation. Distal fixation with long-stemmed extensively coated cementless implants (like the Solution™ system affords a suitable solution. We present our early results of 15 patients treated with extensively coated cementless revision stems. Materials and Methods: Fifteen patients with severely compromised proximal femora following either failed hip arthroplasty or failed internal fixation (dynamic hip screw fixation for intertrochanteric fractures were operated by the senior author over a two-year period. Eight patients had aseptic loosening of their femoral stems following cemented hip replacements, with severe thinning of their proximal cortices and impending stress fractures. Seven had secondary hip arthritis following failure of long implants for comminuted intertrochanteric or subtrochanteric femoral fractures. All patients were treated by removal of implant (cemented stems/DHS implants and insertion of long-stemmed extensively coated cementless revision (′ Solution™; DePuy, Warsaw (IN, US′ stems along with press-fit acetabular component (Duraloc Cup, DePuy, Warsaw (IN, US. All eight hip revisions needed extended trochanteric osteotomies. Results: All patients were primarily kept in bed on physiotherapy for six weeks and then gradually progressed to weight-bearing walking over the next six to eight weeks. The Harris Hip Scores and patient satisfaction were used for final evaluation. We achieved good results in the short term studied. In our first three patients (all following failed cemented total hip replacements, we resorted to cerclage wiring to hold osteotomised segments (done to facilitate stem removal. The subsequent 12 proceeded without the need for cerclage wiring. One patient had a

  19. [Case-control study on effect of rivaroxaban on the risk of hidden bleeding after total hip arthroplasty].

    Science.gov (United States)

    Li, Jun; Jing, Jue-Hua; Shi, Zhan-Jun; Zhou, Yun

    2014-01-01

    To investigate the risk of hidden blood loss about applying rivaroxaban after total hip arthroplasty. From October 2009 to May 2012,88 patients with femoral head necrosis were treated with primary total hip arthroplasty. All the patients were divided into Rivaroxaban group(44 cases)and control group(44 cases). There were 25 males and 19 females in the Rivaroxaban group, with an average age of (58.48 +/- 15.19) years old; in the control group,24 patients were male and 20 patients were female, with an average age of (61.11 +/- 13.54) years old. The patients in the Rivaroxaban group took Rivaroxaban orally from the first day after operation with a dose of 10 mg each day, and treatment course was 14 days. The patients in the control group took placebo orally at the same time. Dominant blood loss and transfusion were recorded, blood routine examinations were taken before operation and at 3 days after operation. The total blood loss and hidden blood loss were calculated according to the formula. The mean total blood loss was (1509.56 +/- 325.23) ml and the hidden blood loss was(581.47 +/- 215.01) ml, accounting for (37.88 +/- 10.42)% in the Rivaroxaban group. The mean total blood loss was (1262.30 +/- 397.95) ml and the hidden blood loss was (395.59 +/- 97.33) ml, accounting for (30.62 +/- 0.20)% in the control group. The total blood loss, hidden blood loss and transfusion in the Rivaroxaban group was significantly more than those in control group,b ut there was no significant difference on dominant blood loss between two groups. Rivaroxaban increased the overall bleeding risk of total hip arthroplasty, especially hidden bleeding risk, which should be careful used.

  20. Periprosthetic bone remodelling of short-stem total hip arthroplasty: a systematic review.

    Science.gov (United States)

    Yan, Shuang G; Weber, Patrick; Steinbrück, Arnd; Hua, Xingyi; Jansson, Volkmar; Schmidutz, Florian

    2017-11-27

    Short-stem hip arthroplasty (SHA) was designed to preserve bone stock and provide an improved load transfer. To gain more evidence regarding the load transfer, this review analysed the periprosthetic bone remodelling of SHA in comparison to standard hip arthroplasty (THA). PubMed and ScienceDirect were screened to extract dual-energy X-ray absorptiometry (DXA) studies evaluating the periprosthetic bone remodelling of SHA and two proven THA designs. From the studies included, the postoperative change in periprosthetic bone mineral density (BMD) after one year and the trend over two years was determined. Fifteen studies with four SHAs (CFP, Metha, Nanos, Fitmore) and two THAs (CLS and Bicontact) designs were included. All SHA and THA stems revealed an initial decrease at the calcar and major trochanter (Gruen 1 and 7) with the Metha, Nanos and Fitmore showing a smaller and more balanced remodelling compared to THA. The pattern after one year and the trend over two years argue for a methaphyseal anchorage of the Metha and Nanos, whereas the Fitmore and CFP seem to anchor metha-diaphyseal. Clearly different pattern of bone remodelling were observed between all four SHAs. Periprosthetic bone remodelling is also present in SHA, with the main bone reduction observed proximally. However, certain SHA stems show a more balanced remodelling compared to THA, arguing for a favourable load transfer. Also, the femoral length where bone remodelling occurs is clearly shorter in SHA. As distinctively different pattern between the SHA designs were observed, they should not be judged as a single implant group.

  1. Dialysis Dependence Predicts Complications, Intensive Care Unit Care, Length of Stay, and Skilled Nursing Needs in Elective Primary Total Knee and Hip Arthroplasty.

    Science.gov (United States)

    Patterson, Joseph T; Tillinghast, Kyle; Ward, Derek

    2018-07-01

    Limited data describe risks and perioperative resource needs of total joint arthroplasty (TJA) in dialysis-dependent patients. Retrospective multiple cohort analysis of dialysis-dependent American College of Surgeons National Surgical Quality Improvement Program patients undergoing primary elective total hip and knee arthroplasty compared to non-dialysis-dependent controls from 2005 to 2015. Relative risks (RRs) of 30-day adverse events were determined by multivariate regression adjusting for baseline differences. Six hundred forty-five (0.2%) dialysis-dependent patients of 342,730 TJA patients were dialysis-dependent and more likely to be dependent, under weight, anemic, hypoalbuminemic, and have cardiopulmonary disease. In total hip arthroplasty patients, dialysis was associated with greater risk of any adverse event (RR = 1.1, P care unit (ICU) care (RR = 9.8, P total knee arthroplasty patients, dialysis conferred greater risk of any adverse event (RR = 1.1, P care (RR = 6.0, P care, longer admission, and rehabilitation needs in TJA patients. Thirty days is not sufficient to detect infectious complications among these patients. These findings inform shared decision-making, perioperative resource planning, and risk adjustment under alternative reimbursement models. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Volume Replacement Therapy during Hip Arthroplasty using Hydroxyethyl Starch (130/0.4 Compared to Lactated Ringer Decreases Allogeneic Blood Transfusion and Postoperative Infection

    Directory of Open Access Journals (Sweden)

    Adilson Hamaji

    2013-01-01

    Full Text Available Background and objectives: Hydroxyethyl starch (HES 130/0.4 is considered an effective plasma expander when compared to crystalloids. There is controversy around its superiority regarding hemodynamic optimization and about possible detrimental effects on coagulation. The aim of this study was to compare the effects of HES 130/0.4 to lactated Ringer solution during hip arthroplasty in adult patients under spinal anesthesia regarding intraoperative bleeding, hemodynamic parameters, coagulation profile, transfusion requirements and clinical outcomes. Methods: In this randomized, controlled trial, 48 patients scheduled for hip arthroplasty with spinal anesthesia were randomized into two groups: 24 patients were allocated to receive a preload of 15 mL.kg-1 of HES 130/0.4 and 24 patients received a preload of 30 mL.kg-1 lactated Ringer solution before surgery. Hemodynamic measurements, hemoglobin concentrations, biochemical parameters and coagulation tests were evaluated in three periods during surgical procedure. Patients received medical follow-up during their hospital stay and up to postoperative 30 days. Primary outcome was the requirement of red blood cell transfusion between groups during hospital stay. Secondary outcome were hemodynamic parameters, length of hospital stay, mortality and occurrence of clinical postoperative complications. Results: Red blood cell transfusion was required in 17% of patients in the HES group and in 46% in the Ringer group (p = .029. Postoperative infections were more frequently observed in the Ringer group (17% compared to the HES group (0, p = .037. There were no significant differences between groups in mortality, hospital length of stay and clinical complications other than infection. Conclusions: During hip arthroplasty, patients treated with hypervolemic hemodilution with hydroxyethyl starch 130/0.4 required less transfusion and presented lower infection rate compared to patients who received lactated

  3. Transitioning to the direct anterior approach in total hip arthroplasty. Is it a true muscle sparing approach when performed by a low volume hip replacement surgeon?

    Science.gov (United States)

    Nistor, Dan-Viorel; Caterev, Sergiu; Bolboacă, Sorana-Daniela; Cosma, Dan; Lucaciu, Dan Osvald Gheorghe; Todor, Adrian

    2017-11-01

    We conducted this study to establish if the transition from a lateral approach (LA) to the direct anterior approach (DAA) for a low volume hip arthroplasty surgeon during the steep learning curve can be performed maintaining the muscle sparing approach of the DAA without increasing the complication rates. In this controlled, prospective, randomized clinical study we investigated 70 patients (35 DAA, 35 LA) with similar demographics that underwent a total hip arthroplasty. Assessment of the two approaches consisted of determining the invasiveness through serum markers for muscle damage (i.e. myoglobin, creatine kinase and lactate dehydrogenase), the operative parameters such as post-operative pain and rescue medication consumption, the component positioning and complication rates. Post-operative myoglobin levels were higher (p < 0.001) in the LA group (326.42 ± 84.91 ng/mL) as compared to the DAA group (242.80 ± 71.03 ng/mL), but with no differences regarding other biomarkers for muscle damage. Pain levels were overall lower in the DAA group, with a statistical and clinical difference during surgery day (p < 0.001) associated with lower (p < 0.001) rescue medication consumption (median 1 (1; 3) mg morphine vs. 3 (2; 4) mg morphine). Most patients in the LA group reported chronic post-operative pain throughout all three evaluated months, while the majority of patients in the DAA group reported no pain after week six. Component positioning did not differ significantly between groups and neither did complication rates. The DAA can be transitioned from the LA safely, without higher complication rates while maintaining its muscle spearing advantages when performed by a low volume hip arthroplasty surgeon.

  4. Trochanteric bursitis after total hip arthroplasty: incidence and evaluation of response to treatment.

    Science.gov (United States)

    Farmer, Kevin W; Jones, Lynne C; Brownson, Kirstyn E; Khanuja, Harpal S; Hungerford, Marc W

    2010-02-01

    We examined the efficacy of corticosteroid injection as treatment for postarthroplasty trochanteric bursitis and the risk factors for failure of nonoperative treatment. There were 32 (4.6%) cases of postsurgical trochanteric bursitis in 689 primary total hip arthroplasties. Of the 25 hips with follow-up, 11 (45%) required multiple injections. Symptoms resolved in 20 (80%) but persisted in 5. We found no statistically significant differences between patients who did and did not develop trochanteric bursitis, or between those who did and did not respond to treatment. There was a trend toward younger age and greater limb-length discrepancy in nonresponders. In conclusion, (1) corticosteroid injection(s) for postoperative trochanteric bursitis is effective; and (2) nonoperative management may be more likely to fail in young patients and those with leg-length discrepancy. 2010 Elsevier Inc. All rights reserved.

  5. Cement-in-cement acetabular revision with a constrained tripolar component.

    Science.gov (United States)

    Leonidou, Andreas; Pagkalos, Joseph; Luscombe, Jonathan

    2012-02-17

    Dislocation of a total hip replacement (THR) is common following total hip arthroplasty (THA). When nonoperative management fails to maintain reduction, revision surgery is considered. The use of constrained acetabular liners has been extensively described. Complete removal of the old cement mantle during revision THA can be challenging and is associated with significant complications. Cement-in-cement revision is an established technique. However, the available clinical and experimental studies focus on femoral stem revision. The purpose of this study was to present a case of cement-in-cement acetabular revision with a constrained component for recurrent dislocations and to investigate the current best evidence for this technique. This article describes the case of a 74-year-old woman who underwent revision of a Charnley THR for recurrent low-energy dislocations. A tripolar constrained acetabular component was cemented over the primary cement mantle following removal of the original liner by reaming, roughening the surface, and thoroughly irrigating and drying the primary cement. Clinical and radiological results were good, with the Oxford Hip Score improving from 11 preoperatively to 24 at 6 months postoperatively. The good short-term results of this case and the current clinical and biomechanical data encourage the use of the cement-in-cement technique for acetabular revision. Careful irrigation, drying, and roughening of the primary surface are necessary. Copyright 2012, SLACK Incorporated.

  6. Does hydroxyapatite coating have no advantage over porous coating in primary total hip arthroplasty? A meta-analysis.

    Science.gov (United States)

    Chen, Yun-Lin; Lin, Tiao; Liu, An; Shi, Ming-Min; Hu, Bin; Shi, Zhong-Li; Yan, Shi-Gui

    2015-01-28

    There are some arguments between the use of hydroxyapatite and porous coating. Some studies have shown that there is no difference between these two coatings in total hip arthroplasty (THA), while several other studies have shown that hydroxyapatite has advantages over the porous one. We have collected the studies in Pubmed, MEDLINE, EMBASE, and the Cochrane library from the earliest possible years to present, with the search strategy of "(HA OR hydroxyapatite) AND ((total hip arthroplasty) OR (total hip replacement)) AND (RCT* OR randomiz* OR control* OR compar* OR trial*)". The randomized controlled trials and comparative observation trials that evaluated the clinical and radiographic effects between hydroxyapatite coating and porous coating were included. Our main outcome measurements were Harris hip score (HHS) and survival, while the secondary outcome measurements were osteolysis, radiolucent lines, and polyethylene wear. Twelve RCTs and 9 comparative observation trials were included. Hydroxyapatite coating could improve the HHS (p hydroxyapatite coating had no advantages on survival (p = 0.32), polyethylene wear (p = 0.08), and radiolucent lines (p = 0.78). Hydroxyapatite coating has shown to have an advantage over porous coating. The HHS and survival was duration-dependent-if given the sufficient duration of follow-up, hydroxyapatite coating would be better than porous coating for the survival. The properties of hydroxyapatite and the implant design had influence on thigh pain incidence, femoral osteolysis, and polyethylene wear. Thickness of 50 to 80 μm and purity larger than 90% increased the thigh pain incidence. Anatomic design had less polyethylene wear.

  7. Ideal femoral head size in total hip arthroplasty balances stability and volumetric wear.

    Science.gov (United States)

    Cross, Michael B; Nam, Denis; Mayman, David J

    2012-10-01

    Over the last several years, a trend towards increasing femoral head size in total hip arthroplasty to improve stability and impingement free range of motion has been observed. The specific questions we sought to answer in our review were: (1) What are the potential advantages and disadvantages of metal-on-metal, ceramic-on-ceramic, and metal-on-polyethylene bearings? (2) What is effect that femoral head size has on joint kinematics? (3) What is the effect that large femoral heads have on bearing surface wear? A PubMed search and a review of 2012 Orthopaedic Research Society abstracts was performed and articles were chosen that directly answered components of the specific aims and that reported outcomes with contemporary implant designs or materials. A review of the literature suggests that increasing femoral head size decreases the risk of postoperative dislocation and improves impingement free range of motion; however, volumetric wear increases with large femoral heads on polyethylene and increases corrosion of the stem in large metal-on-metal modular total hip arthroplasty (THA); however, the risk of potentially developing osteolysis or adverse reactions to metal debris respectively is still unknown. Further, the effect of large femoral heads with ceramic-on-ceramic THA is unclear, due to limited availability and published data. Surgeons must balance the benefits of larger head size with the increased risk of volumetric wear when determining the appropriate head size for a given patient.

  8. Don't forget the hip! Hip arthritis masquerading as knee pain

    Directory of Open Access Journals (Sweden)

    Florian F. Dibra, MD

    2018-03-01

    Full Text Available Background: Hip osteoarthritis typically manifests with groin or thigh pain. Other atypical pain patterns, including knee pain, have been described. Except for 2 case reports, there is no literature on this subject. Methods: From our institutional database, between 2011 and 2016, we identified 21 patients who were referred for treatment of knee pain but ultimately diagnosed with hip pathology as the cause of their pain. This group was evaluated for duration of symptoms prior to diagnosis, previous interventions, presence of walking aids, and symptom resolution after treatment of the hip pathology. Results: Fifteen of the 21 patients were referred from musculoskeletal providers (12 from orthopaedic surgeons. Prior to diagnosis of the hip etiology, 16 patients were reduced to major assistive devices including wheelchairs. Twelve of 21 patients had undergone surgical knee interventions, including total knee arthroplasty, with minimal to no relief of their pain. Seventeen of 21 referred patients underwent total hip arthroplasty at our institution. Fourteen patients had complete resolution of knee pain after total hip arthroplasty. Conclusions: Although knee pain referred from hip disease may be considered a basic and common knowledge, it continues to be an overlooked phenomenon. Most of the cases were misdiagnosed by musculoskeletal providers including orthopaedic surgeons and this highlights the need for continued education and awareness of this clinical scenario. Keywords: Hip pain, Knee pain, Referred pain, Delay in diagnosis, Unnecessary surgery

  9. Improvement in quality of lifesix months after primary total hip arthroplasty in a Pakistani population.

    Science.gov (United States)

    Zubairi, Akbar Jaleel; Bin Mahmood, Syed Usman; Ali, Moiz; Noordin, Shahryar

    2016-10-01

    This prospective, cohort study was carried out to assess the improvement in quality of life of patients undergoing elective primary total hip arthroplasty (THA). It was conducted at the orthopaedic department of the Aga Khan University Hospital, Karachi, from June 2014 to May 2015, and comprised patients who had undergone THA. A total of 89 patients having a mean age of 41.5±12.0 years with a baseline core outcomes measure index (COMI)-hip score of > 3.5 were included. A decrease in COMI-hip score by >3 points six months post-operatively was considered improvement in quality of life. Patient satisfaction with restriction to squatting was assessed separately. The mean reduction in COMI-hip was 4.9±1.3 with 83(93%) patients experiencing significant improvement in quality of life. Age >50 years and American Society of Anaesthesiologists (ASA) level >III was significantly associated with no improvement in quality of life. Most patients were satisfied with their disability to squat irrespective of COMI-hip score. THA was found to be associated with significant improvement in quality of life and COMI-hip score was applicable in our population despite its inability to assess disability with restriction in squatting.

  10. Staged Custom, Intramedullary Antibiotic Spacers for Severe Segmental Bone Loss in Infected Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Atul F. Kamath

    2011-01-01

    Full Text Available Introduction. Total hip arthroplasty (THA infections with severe bone loss pose significant reconstructive challenges. We present our experience with two-stage hip reimplantation using an intramedullary, antibiotic-impregnated nail. Methods. Three patients with infected THA with severe proximal femoral bone loss (Mallory type IIIB or greater were treated using a custom antibiotic spacer. Clinical outcomes and any complications were recorded. Average followup was 49 months from final reimplantation. Results. Mean age at spacer placement (stage 1 was 53 years. The mean Harris Hip Score at final followup was 80. Two patients had asymptomatic heterotopic ossification, and one patient had a 2 cm leg-length discrepancy. Conclusions. A custom intramedullary nail antibiotic spacer is a reliable option in the staged management of the infected THA with severe proximal femoral bone loss. Benefits of this technique include limb salvage with maintenance of leg length, soft tissue tension, and functional status.

  11. Optical 3D methods for measurement of prosthetic wear of total hip arthroplasty: principles, verification and results

    Czech Academy of Sciences Publication Activity Database

    Rössler, T.; Mandát, Dušan; Gallo, J.; Hrabovský, Miroslav; Pochmon, Michal; Havránek, Vítězslav

    2009-01-01

    Roč. 17, č. 15 (2009), 12723-12730 ISSN 1094-4087 R&D Projects: GA MŠk(CZ) 1M06002 Grant - others:GA MŠk(CZ) OC 168 Program:OC Institutional research plan: CEZ:AV0Z10100522 Keywords : 3D methods * total hip arthroplasty Subject RIV: BH - Optics, Masers, Lasers Impact factor: 3.278, year: 2009

  12. Greater Trochanteric Fixation Using a Cable System for Partial Hip Arthroplasty: A Clinical and Finite Element Analysis

    Directory of Open Access Journals (Sweden)

    Fırat Ozan

    2014-01-01

    Full Text Available The aim of the study was to investigate the efficacy of greater trochanteric fixation using a multifilament cable to ensure abductor lever arm continuity in patients with a proximal femoral fracture undergoing partial hip arthroplasty. Mean age of the patients (12 men, 20 women was 84.12 years. Mean follow-up was 13.06 months. Fixation of the dislocated greater trochanter with or without a cable following load application was assessed by finite element analysis (FEA. Radiological evaluation was based on the distance between the fracture and the union site. Harris hip score was used to evaluate final results: outcomes were excellent in 7 patients (21.8%, good in 17 patients (53.1%, average in 5 patients (15.6%, and poor in 1 patient (9.3%. Mean abduction angle was 20.21°. Union was achieved in 14 patients (43.7%, fibrous union in 12 (37.5%, and no union in 6 (18.7%. FEA showed that the maximum total displacement of the greater trochanter decreased when the fractured bone was fixed with a cable. As the force applied to the cable increased, the displacement of the fractured trochanter decreased. This technique ensures continuity of the abductor lever arm in patients with a proximal femoral fracture who are undergoing partial hip arthroplasty surgery.

  13. Advantages and disadvantages of ceramic on ceramic total hip arthroplasty: a review.

    Science.gov (United States)

    Gallo, Jiri; Goodman, Stuart Barry; Lostak, Jiri; Janout, Martin

    2012-09-01

    Ceramic on ceramic (COC) total hip arthroplasty (THA) was developed to reduce wear debris and accordingly, the occurrence of osteolysis and aseptic loosening especially in younger patients. Based on the excellent tribological behavior of current COC bearings and the relatively low biological activity of ceramic particles, significant improvement in survivorship of these implants is expected. We used manual search to identify all relevant studies reporting clinical data on COC THAs in PubMed. The objective was to determine whether current COC THA offers a better clinical outcome and survivorship than non-COC THA. Studies with early generation ceramic bearings yielded 68% to 84% mean survivorship at 20 years follow-up which is comparable with the survivorship of non-COC THAs. Studies on current ceramic bearings report a 10-year revision-free interval of 92% to 99%. These outcomes are comparable to the survivorship of the best non-COC THAs. However, there are still concerns regarding fracture of sandwich ceramic liners, squeaking, and impingement of the femoral neck on the rim of the ceramic liner leading to chipping, especially in younger and physically active patients. Current COC THA leads to equivalent but not improved survivorship at 10 years follow-up in comparison to the best non-COC THA. Based on this review, we recommend that surgeons weigh the potential advantages and disadvantages of current COC THA in comparison to other bearing surfaces when considering young very active patients who are candidates for THA.

  14. Release of Gentamicin and Vancomycin from Preformed Spacers in Infected Total Hip Arthroplasties: Measurement of Concentrations and Inhibitory Activity in Patients’ Drainage Fluids and Serum

    Directory of Open Access Journals (Sweden)

    Dario Regis

    2013-01-01

    Full Text Available Gentamicin (G and vancomycin (V concentrations in drainage fluids obtained from patients during the first 24 hours after implantation of antibiotic-loaded polymethylmethacrylate (PMMA spacers in two-stage revision of infected total hip arthroplasty were studied. The inhibitory activity of drainage fluids against different multiresistant clinical isolates was investigated as well. Seven hips were treated by implantation of industrial G-loaded spacers. Vancomycin was added by manually mixing with PMMA bone cement. Serum and drainage fluid samples were collected 1, 4, and 24 hours after spacer implantation. Antibiotics concentrations and drains bactericidal titer of combination were determined against multiresistant staphylococcal strains. The release of G and V from PMMA cement at the site of infection was prompt and effective. Serum levels were below the limit of detection. The local release kinetics of G and V from PMMA cement was similar, exerting a pronounced, combined inhibitory effect in the implant site. The inhibitory activity of drainage fluids showed substantial intersubject variability related to antibiotic concentrations and differed according to the pathogens tested. Gentamicin and vancomycin were released from temporary hip spacers at bactericidal concentrations, and their use in combination exerted strong inhibition against methicillin-resistant S. aureus and Coagulase Negative Staphylococci strains.

  15. Periprosthetic fungal infection of a hip caused by Trichosporon inkin

    Directory of Open Access Journals (Sweden)

    Federico José Burgo, MD

    2018-03-01

    Full Text Available An immunocompromised patient with a history of multiple hip implant revisions extended courses of empiric antibiotic treatment, and a retained metallic rod in the femoral medullary canal was transferred for diagnostic studies and treatment. A high suspicion of fungal infection and utilization of extended and specific fungal cultures were the diagnostic keys for infection with Trichosporon inkin. The treatment consisted in a debridement surgery with the use of a functional spacer with cement supplemented with voriconazole and vancomycin plus a 6-month systemic treatment with voriconazole. After 2 years of follow-up, the patient is free of symptoms. Keywords: Hip arthroplasty, Periprosthetic fungal infection, Trichosporon inkin

  16. Acetabular bone density and metal ions after metal-on-metal versus metal-on-polyethylene total hip arthroplasty; short-term results

    NARCIS (Netherlands)

    Zijlstra, Wierd P.; van der Veen, Hugo C.; van den Akker-Scheek, Inge; Zee, Mark J. M.; Bulstra, Sjoerd K.; van Raay, Jos J. A. M.

    Information on periprosthetic acetabular bone density is lacking for metal-on-metal total hip arthroplasties. These bearings use cobalt-chromium instead of titanium acetabular components, which could lead to stress shielding and hence periprosthetic bone loss. Cobalt and chromium ions have

  17. Reliability of using DXA around RTHAs. Bone Mineral Density of the femoral neck in resurfacing hip arthroplasty

    DEFF Research Database (Denmark)

    Penny, Jeannette Østergaard; Ovesen, Ole; Brixen, Kim

    2010-01-01

      Background and purpose: Resurfacing Total Hip Arthroplasty (RTHA) may preserve the femoral neck bone-stock post-operatively. Bone Mineral Density (BMD), could theoretically be affected by the hip-position, and bias longitudinal studies. We aimed to investigate BMD precision dependency on type...... was rotated in increments of 15° and 30°, the mean CVs rose to 7.2%, 7.3% and 11.8%.  Rotation affected the precision most in the model that divided the neck in 6 sub regions, predominantly in the lateral and distal regions. For larger-region models, some rotation could be allowed without compromising...

  18. Total hip arthroplasty in patients with ankylosing spondylitis: Midterm radiologic and functional results

    Directory of Open Access Journals (Sweden)

    Yavuz Saglam

    2016-08-01

    Conclusion: Revision incidence was similar in between ankylosed and non-ankylosed hips. While complication rates are high, significant functional improvement can be achieved after THA in patients with AS.

  19. Hip arthroplasty today and tomorrow.

    Science.gov (United States)

    Amstutz, H C

    1987-12-01

    Acrylic-fixed total hip and surface replacement arthroplasty have been very effective in affording immediate relief of pain and providing improved function. Complications have been reduced by improvements in design, materials, and especially technique. They are now very low in the elderly, and the stem type acrylic-fixed design remains the procedure of choice. The failure rates in youthful patients and those with bone-stock deficiencies have been high in both THR and surface types, although the latter had the advantage of preserving femoral stock. On the femoral side, the new "macro" femoral designs from Europe and "micro" femoral porous designs have shown promise, but thigh pain, incomplete and difficult to predict bone ingrowth patterns, coupled with removal problems have influenced design and technique changes. Both press-fit stem types and porous surface replacements have produced promising initial results with less potential downside risks. On the acetabular side, both the cementless hemispherical with screw-type adjuvant fixation, or the chamfered cylinder designs, used primarily with the UCLA porous surface replacements, but also with stem-type devices, appear to achieve best short-term results, while the entire variety of screw rings are disappointing. The future will bring further refinements in technique and specific indications for certain types of replacement stem in specific types of bone stock deficiencies. The all ceramic-ceramic and ceramic-polyethylene bearings show promise of reducing wear and, hence, should improve longevity of implant fixation.

  20. Changes in social isolation and loneliness following total hip and knee arthroplasty: longitudinal analysis of the English Longitudinal Study of Ageing (ELSA) cohort.

    Science.gov (United States)

    Smith, T O; Dainty, J R; MacGregor, A J

    2017-09-01

    To determine the prevalence and change in social isolation and loneliness in people before and after total hip arthroplasty (THA) and total knee arthroplasty (TKA) in England. The English Longitudinal Study of Ageing (ELSA) dataset, a prospective study of community-dwelling older adults, was used to identify people who had undergone primary THA or TKA because of osteoarthritis. Social isolation was assessed using the ELSA Social Isolation Index. Loneliness was evaluated using the Revised University of California, Los Angeles (UCLA) Loneliness Scale. The prevalence of social isolation and loneliness were calculated and multilevel modelling was performed to assess the potential change of these measures before arthroplasty, within a two-year operative-recovery phase and a following two-year follow-up. The sample consisted of 393 people following THA and TKA. The prevalence of social isolation and loneliness changed from 16.9% to 18.8% pre-operative to 21.8% and 18.9% at the final post-operative follow-up respectively. This was not a statistically significant change for either measure (P = 0.15; P = 0.74). There was a significant difference in social isolation at the recovery phase compared to the pre-operative phase (P = 0.01), where people following arthroplasty reported an increase in social isolation (16.9-21.4%). There was no significant difference between the assessment phases in respect to UCLA Loneliness Scale score (P ≥ 0.74). Given the negative physical and psychological consequences which social isolation and loneliness can have on individuals following THA or TKA, clinicians should be mindful of this health challenge for this population. The reported prevalence of social isolation and loneliness suggests this is an important issue. Copyright © 2017 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  1. Digestive Fistula Due to Acetabular Protrusion: Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Carlos Marqués

    2017-12-01

    Full Text Available Intrapelvic migration of the acetabular component after primary or revision hip arthroplasty is a rare complication. We present a case of an intrapelvic migration of the acetabular component after a revision hip arthroplasty which led to an enteric fistula to the hip joint as well as to a sigmoid colon perforation.

  2. The efficacy of levobupivacaine, ropivacaine, and bupivacaine for combined psoas compartment-sciatic nerve block in patients undergoing total hip arthroplasty

    NARCIS (Netherlands)

    de Leeuw, M.A.; Dertinger, J.A.; Hulshoff, L.; Hoeksema, M.; Perez, R.S.G.M.; Zuurmond, W.W.A.; de Lange, J.J.

    2008-01-01

    Background and Objectives: The aim of our study was to compare postoperative analgesic efficacy, and the extent of sensory and motor blockade of levobupivacaine, ropivacaine, and bupivacaine administered in a combined psoas compartment-sciatic nerve block (PCSNB) for total hip arthroplasty. Methods:

  3. Ceramic-on-ceramic bearing fractures in total hip arthroplasty: an analysis of data from the National Joint Registry.

    Science.gov (United States)

    Howard, D P; Wall, P D H; Fernandez, M A; Parsons, H; Howard, P W

    2017-08-01

    Ceramic-on-ceramic (CoC) bearings in total hip arthroplasty (THA) are commonly used, but concerns exist regarding ceramic fracture. This study aims to report the risk of revision for fracture of modern CoC bearings and identify factors that might influence this risk, using data from the National Joint Registry (NJR) for England, Wales, Northern Ireland and the Isle of Man. We analysed data on 223 362 bearings from 111 681 primary CoC THAs and 182 linked revisions for bearing fracture recorded in the NJR. We used implant codes to identify ceramic bearing composition and generated Kaplan-Meier estimates for implant survivorship. Logistic regression analyses were performed for implant size and patient specific variables to determine any associated risks for revision. A total of 222 852 bearings (99.8%) were CeramTec Biolox products. Revisions for fracture were linked to seven of 79 442 (0.009%) Biolox Delta heads, 38 of 31 982 (0.119%) Biolox Forte heads, 101 of 80 170 (0.126%) Biolox Delta liners and 35 of 31 258 (0.112%) Biolox Forte liners. Regression analysis of implant size revealed smaller heads had significantly higher odds of fracture (chi-squared 68.0, p ceramic type. Liner thickness was not predictive of fracture (p = 0.67). Body mass index (BMI) was independently associated with revision for both head fractures (odds ratio (OR) 1.09 per unit increase, p = 0.031) and liner fractures (OR 1.06 per unit increase, p = 0.006). We report the largest independent study of CoC bearing fractures to date. The risk of revision for CoC bearing fracture is very low but previous studies have underestimated this risk. There is good evidence that the latest generation of ceramic has greatly reduced the odds of head fracture but not of liner fracture. Small head size and high patient BMI are associated with an increased risk of ceramic bearing fracture. Cite this article: Bone Joint J 2017;99-B:1012-19. ©2017 The British Editorial Society of Bone & Joint Surgery.

  4. The efficiency of risedronate in reducing bone resorption after total hip arthroplasty: a meta-analysis of randomized control trials at a minimum of 6 months' follow-up.

    Science.gov (United States)

    Yang, Liqing

    2018-04-17

    Recently risedronate is suggested to be effective for the prevention and treatment of for osteoporosis in total hip arthroplasty. This meta-analysis aimes to evaluate the efficacy of risedronate in reducing femoral periprosthetic bone mineral density loss in patients undergoing primary total hip arthroplasty. A systematic search was performed in Medline (1966-31 October 2017), PubMed (1966-31 October 2017), Embase (1980-31 October 2017), ScienceDirect (1985-31 October 2017) and the Cochrane Library. Only randomized controlled trial (RCT) were included. Fixed/random effect model was used according to the heterogeneity tested by I2 statistic. Meta-analysis was performed using Stata 11.0 software. The outcome measures included periprosthetic bone mineral density, length of stay and adverse effects. Four RCTs including 198 patients met the inclusion criteria. The present meta-analysis showed that there were significant differences between treatment groups in terms of periprosthetic bone mineral density in Gruen zones 1 (standard mean difference (SMD) = 0.758, 95% CI 0.469 to 1.047, P = 0.000), 2 (SMD = 0.814, 95% CI 0.523 to 1.106, P = 0.000), 3 (SMD = 0.340, 95% CI 0.059 to 0.622, P = 0.018), 6 (SMD = 2.400, 95% CI 2.029 to 2.771, P = 0.000), and 7 (SMD = 2.400, 95% CI 2.029 to 2.771, P = 0.000). Oral risedronate could significantly reduce periprosthetic bone resorption around an uncemented femoral stem (Gruen zones 1, 2, 3, 6, and 7) up to 6 months after THA. In addition, no severe adverse events were identified. Future trials of risedronate treatment after THA should focus on clinically relevant end points such as the risks of fracture and revision arthroplasty.

  5. Multimodal analgesia with gabapentin, ketamine and dexamethasone in combination with paracetamol and ketorolac after hip arthroplasty: a preliminary study

    DEFF Research Database (Denmark)

    Rasmussen, Michael; Mathiesen, Ole; Dierking, Gerd

    2010-01-01

    It has been hypothesized that combinations of analgesics with different mechanisms of action may reduce or even prevent postoperative pain. We, therefore, investigated the analgesic effect of gabapentin, dexamethasone and low-dose ketamine in combination with paracetamol and ketorolac as compared...... with paracetamol and ketorolac alone after hip arthroplasty....

  6. Gait symmetry and hip strength in women with developmental dysplasia following hip arthroplasty compared to healthy subjects: A cross-sectional study.

    Directory of Open Access Journals (Sweden)

    Ruud A Leijendekkers

    Full Text Available Untreated unilateral developmental dysplasia of the hip (DDH results in asymmetry of gait and hip strength and may lead to early osteoarthritis, which is commonly treated with a total hip arthroplasty (THA. There is limited knowledge about the obtained symmetry of gait and hip strength after the THA. The objectives of this cross-sectional study were to: a identify asymmetries between the operated and non-operated side in kinematics, kinetics and hip strength, b analyze if increased walking speed changed the level of asymmetry in patients c compare these results with those of healthy subjects.Women (18-70 year with unilateral DDH who had undergone unilateral THA were eligible for inclusion. Vicon gait analysis system was used to collect frontal and sagittal plane kinematic and kinetic parameters of the hip joint, pelvis and trunk during walking at comfortable walking speed and increased walking speed. Furthermore, hip abductor and extensor muscle strength was measured.Six patients and eight healthy subjects were included. In the patients, modest asymmetries in lower limb kinematics and kinetics were present during gait, but trunk lateral flexion asymmetry was evident. Patients' trunk lateral flexion also differed compared to healthy subjects. Walking speed did not significantly influence the level of asymmetry. The hip abduction strength asymmetry of 23% was not statistically significant, but the muscle strength of both sides were significantly weaker than those of healthy subjects.In patients with a DDH treated with an IBG THA modest asymmetries in gait kinematics and kinetics were present, with the exception of a substantial asymmetry of the trunk lateral flexion. Increased walking speed did not result in increased asymmetries in gait kinematics and kinetics. Hip muscle strength was symmetrical in patients, but significantly weaker than in healthy subjects. Trunk kinematics should be included as an outcome measure to assess the biomechanical

  7. Radiographic Underestimation of In Vivo Cup Coverage Provided by Total Hip Arthroplasty for Dysplasia.

    Science.gov (United States)

    Nie, Yong; Wang, HaoYang; Huang, ZeYu; Shen, Bin; Kraus, Virginia Byers; Zhou, Zongke

    2018-01-01

    The accuracy of using 2-dimensional anteroposterior pelvic radiography to assess acetabular cup coverage among patients with developmental dysplasia of the hip after total hip arthroplasty (THA) remains unclear in retrospective clinical studies. A group of 20 patients with developmental dysplasia of the hip (20 hips) underwent cementless THA. During surgery but after acetabular reconstruction, bone wax was pressed onto the uncovered surface of the acetabular cup. A surface model of the bone wax was generated with 3-dimensional scanning. The percentage of the acetabular cup that was covered by intact host acetabular bone in vivo was calculated with modeling software. Acetabular cup coverage also was determined from a postoperative supine anteroposterior pelvic radiograph. The height of the hip center (distance from the center of the femoral head perpendicular to the inter-teardrop line) also was determined from radiographs. Radiographic cup coverage was a mean of 6.93% (SD, 2.47%) lower than in vivo cup coverage for these 20 patients with developmental dysplasia of the hip (Pcup coverage (Pearson r=0.761, Pcup (P=.001) but not the position of the hip center (high vs normal) was significantly associated with the difference between radiographic and in vivo cup coverage. Two-dimensional radiographically determined cup coverage conservatively reflects in vivo cup coverage and remains an important index (taking 7% underestimation errors and the effect of greater underestimation of larger cup size into account) for assessing the stability of the cup and monitoring for adequate ingrowth of bone. [Orthopedics. 2018; 41(1):e46-e51.]. Copyright 2017, SLACK Incorporated.

  8. [Mid-term effectiveness of total hip arthroplasty with collum femoris preserving prosthesis].

    Science.gov (United States)

    Li, Mingqing; Hu, Yihe; Li, Kanghua; Liao, Qiande; Wen, Ting; Zhong, Da

    2012-08-01

    To discuss the clinical application of total hip arthroplasty (THA) with collum femoris preserving (CFP) prosthesis and to analyze the mid-term effectiveness. Between January 2004 and February 2007, 45 patients (48 hips) underwent THA with CFP prosthesis. There were 29 males (31 hips) and 16 females (17 hips) with an average age of 48.8 years (range, 38-60 years), including 20 left hips, 22 right hips, and 3 bilateral hips. The causes of hip replacement were osteoarthritis (20 cases), avascular necrosis of femoral head (13 cases), dysplasia (4 cases), rheumatoid arthritis (3 cases), posttraumatic osteoarthritis (2 cases), ankylosing spondylitis (2 cases), and Perths disease (1 case). The average disease duration was 6.1 years (range, 2-13 years). Harris scores, visual analogue scale (VAS) score, and the hip range of motion (ROM) were recorded at pre- and post-operation. The X-ray films were taken at pre- and post-operation to observe the position, loosening of the prosthesis, and ectopic ossification. The gait of patients were also evaluated during follow-up. Short-form 36 health survey scale (SF-36) was used to evaluate the life quality of patients. All 45 patients were followed up 5-8 years with an average of 6.4 years. All the incisions healed by first intention. No infection, hip dislocation, nerve injury, or deep vein thrombosis occurred. Six cleavage fractures (13.3%) of the lateral femoral diaphysis at the distal prosthesis occurred during operation, which healed at 8 months postoperatively without any treatment. Mild ectopic ossification occurred in 4 patients (8.9%) who had no discomfort. Five patients (11.1%) had bone mineral density loss in the region of the proximal femur. The survival rates of the cups and stems were all 100% at last follow-up. The results of Harris score, VAS score, and ROM of the hip joint at 1 year postoperatively and last follow-up were significantly better than preoperative ones (P 0.05) except the Harris score (P fair in 6 hips

  9. Orthostatic intolerance during early mobilization after fast-track hip arthroplasty

    DEFF Research Database (Denmark)

    Jans, O; Bundgaard-Nielsen, M; Solgaard, S

    2012-01-01

    has not been established after THA. This study evaluated the cardiovascular response and tissue oxygenation to mobilization before and after surgery in relation to OI in fast-track THA patients. METHODS: /st>OI and the cardiovascular response to standing were evaluated with a standardized mobilization......BACKGROUND: /st>Early postoperative mobilization is a cornerstone in fast-track total hip arthroplasty (THA), but postoperative orthostatic intolerance (OI) may delay early recovery or lead to fainting, falls, and prosthesis dislocation or fracture. However, the prevalence and pathophysiology of OI...... protocol, before, 6, and 24 h after surgery in 26 patients undergoing THA with spinal anaesthesia and an opioid-sparing analgesic regime. Haemoglobin, fluid balance, and opioid use were recorded. Systolic (SAP) and diastolic (DAP) arterial pressure, heart rate (HR), stroke volume (SV), cardiac output (CO...

  10. Hydrotherapy after total hip arthroplasty: a follow-up study.

    Science.gov (United States)

    Giaquinto, S; Ciotola, E; Dall'armi, V; Margutti, F

    2010-01-01

    The aim of the study was to evaluate the subjective functional outcome of total hip arthroplasty (THA) in patients who underwent hydrotherapy (HT) 6 months after discharge. A prospective randomized study was performed on 70 elderly inpatients with recent THA, who completed a rehabilitation program. After randomization, 33 of them were treated in conventional gyms (no-hydrotherapy group=NHTG) and 31 received HT (hydrotherapy group=HTG). Interviews with the Western-Ontario MacMasters Universities Osteoarthritis Index (WOMAC) were performed at admission, at discharge and 6 months later. Kruskal-Wallis, Mann-Whitney and Wilcoxon tests were applied for statistical analysis. Both groups improved. Pain, stiffness and function were all positively affected. Statistical analysis indicated that WOMAC sub-scales were significantly lower for all patients treated with HT. The benefits at discharge still remained after 6 months. We conclude that HT is recommended after THA in a geriatric population.

  11. Intra-articular steroid injection for osteoarthritis of the hip prior to total hip arthroplasty : is it safe? a systematic review.

    Science.gov (United States)

    Pereira, L C; Kerr, J; Jolles, B M

    2016-08-01

    Using a systematic review, we investigated whether there is an increased risk of post-operative infection in patients who have received an intra-articular corticosteroid injection to the hip for osteoarthritis prior to total hip arthroplasty (THA). Studies dealing with an intra-articular corticosteroid injection to the hip and infection following subsequent THA were identified from databases for the period between 1990 to 2013. Retrieved articles were independently assessed for their methodological quality. A total of nine studies met the inclusion criteria. Two recommended against a steroid injection prior to THA and seven found no risk with an injection. No prospective controlled trials were identified. Most studies were retrospective. Lack of information about the methodology was a consistent flaw. The literature in this area is scarce and the evidence is weak. Most studies were retrospective, and confounding factors were poorly defined or not addressed. There is thus currently insufficient evidence to conclude that an intra-articular corticosteroid injection administered prior to THA increases the rate of infection. High quality, multicentre randomised trials are needed to address this issue. Cite this article: Bone Joint J 2016;98-B:1027-35. ©2016 The British Editorial Society of Bone & Joint Surgery.

  12. Post-anaesthesia care unit stay after total hip and knee arthroplasty under spinal anaesthesia

    DEFF Research Database (Denmark)

    Lunn, T H; Kristensen, B B; Gaarn-Larsen, L

    2012-01-01

    patients operated with primary unilateral total hip or knee arthroplasty (THA or TKA) under spinal anaesthesia were included in this hypothesis-generating, prospective, observational cohort study during a 4-month period. Surgical technique, analgesia, and perioperative care were standardized. Well......BACKGROUND: Post-anaesthesia care unit (PACU) admission must be well founded and the stay as short as possible without compromising patient safety. However, within the concept of fast-track surgery, studies are limited in addressing the question: why are patients staying in the PACU? METHODS: All...

  13. Taking care of your new hip joint

    Science.gov (United States)

    Hip arthroplasty - precautions; Hip replacement - precautions; Osteoarthritis - hip; Osteoarthritis - knee ... After you have hip replacement surgery, you will need to be careful how you move your hip, especially for the first few months ...

  14. The effect of a single infusion of zoledronic acid on early implant migration in total hip arthroplasty. A randomized, double-blind, controlled trial.

    Science.gov (United States)

    Friedl, Gerald; Radl, Roman; Stihsen, Christoph; Rehak, Peter; Aigner, Reingard; Windhager, Reinhard

    2009-02-01

    Aseptic loosening is the most frequent cause of implant failure in total hip arthroplasty. While a direct link between aseptic loosening and periprosthetic bone loss remains elusive, there is plentiful evidence for a close association with early implant migration. The present trial was primarily designed to evaluate whether a single infusion of 4 mg of zoledronic acid prevented early implant migration in patients with osteonecrosis of the femoral head. Fifty patients were consecutively enrolled to receive either zoledronic acid or saline solution after cementless total hip arthroplasty. Radiographs, biochemical parameters of bone turnover, and the Harris hip-rating score were determined preoperatively and at each follow-up examination at seven weeks, six months, one year, and yearly thereafter. The median follow-up period was 2.8 years. We found a significant subsidence of the stem of up to a mean (and standard deviation) of -1.2 +/- 0.6 mm at two years within the control group, and the cups had a mean medialization of 0.6 +/- 1.0 mm and a mean cranialization of 0.6 +/- 0.8 mm (p < 0.001). Treatment with zoledronic acid effectively minimized the migration of the cups in both the transverse and the vertical direction (mean, 0.15 +/- 0.6 mm and 0.06 +/- 0.6 mm, respectively; p < 0.05), while only a trend to decreased subsidence of the stem was detected. Finally, the Harris hip score rapidly increased over time in both treatment groups, although this increase was significantly more pronounced in the zoledronate-treated group than in the control group (analysis of variance, p = 0.008). A single infusion of zoledronic acid shows promise in improving initial fixation of a cementless implant, which may improve the clinical outcome of total hip arthroplasty in patients with osteonecrosis of the femoral head.

  15. Failure rate of cemented and uncemented total hip replacements

    DEFF Research Database (Denmark)

    Makela, K. T.; Matilainen, M.; Pulkkinen, P.

    2014-01-01

    ). Participants 347 899 total hip replacements performed during 1995-2011. Main outcome measures Probability of implant survival (Kaplan-Meier analysis) along with implant survival with revision for any reason as endpoint (Cox multiple regression) adjusted for age, sex, and diagnosis in age groups 55-64, 65......Objective To assess the failure rate of cemented, uncemented, hybrid, and reverse hybrid total hip replacements in patients aged 55 years or older. Design Register study. Setting Nordic Arthroplasty Register Association database (combined data from Sweden, Norway, Denmark, and Finland......-74, and 75 years or older. Results The proportion of total hip replacements using uncemented implants increased rapidly towards the end of the study period. The 10 year survival of cemented implants in patients aged 65 to 74 and 75 or older (93.8%, 95% confidence interval 93.6% to 94.0% and 95.9%, 95...

  16. Follow-up after arthroplasty of the hip and knee : are we over-servicing or under-caring?

    Science.gov (United States)

    Lovelock, T M; Broughton, N S

    2018-01-01

    The number of arthroplasties of the hip and knee is predicted to increase rapidly during the next 20 years. Accompanying this is the dilemma of how to follow-up these patients appropriately. Current guidelines recommend long-term follow-up to identify patients with aseptic loosening, which can occur more than a decade postoperatively. The current guidelines and practices of orthopaedic surgeons vary widely. Existing models take up much clinical time and are expensive. Pilot studies using 'virtual' clinics and advanced-practice physiotherapists have shown promise in decreasing the time and costs for orthopaedic surgeons and patients. This review discusses current practices and future trends in the follow-up of patients who have an arthroplasty. Cite this article: Bone Joint J 2018;100-B:6-10. ©2018 The British Editorial Society of Bone & Joint Surgery.

  17. Low friction arthroplasty and dual mobility cup: a new gold standard.

    Science.gov (United States)

    Prudhon, Jean Louis; Verdier, Régis; Caton, Jacques H

    2017-03-01

    Low friction arthroplasty (LFA) introduced by Sir John Charnley was the gold standard for many years. Dislocation and infection are the first causes for early revision. Late failures are polyethylene (PE) wear and loosening. Due to dislocation risk we slowly switched to the use of LFA with dual mobility cups (DMC). The purposes of this study are (1) to assess whether our changes have improved outcomes and (2) what is the new gold standard? We selected from an observational registry of 1,091 cases of hybrid Charnley total hip arthroplasty (THA). The acetabular component was either DMC in 455 cases or fixed cup (FC) in 636 cases. Three dislocations (0.6%) occurred in the DMC group (none revised). In the FC group 54 dislocated (8.49%) and 20 were recurrent and underwent revision (revision rate 3.14%). In the DMC group, five acetabular and three femoral revisions were performed (revision rate for loosening 1.7%). In the FC group 19 cases underwent acetabular revision, and five cases had femoral component revised (revision rate for loosening 3.7%). Charnley's LFA has proven over 50 years of excellent survivorship. To decrease dislocation risk, one suggested increasing femoral head diameter. Gilles Bousquet proposed another way, namely, the DMC concept. Dislocation is no longer a critical issue with DMC as demonstrated in our series and main series. DMC in primary THA is still a subject of debate. Mid-term results do not demonstrate a higher rate of wear than LFA. What is the current gold standard? LFA was and is our current gold standard in association with a DMC.

  18. Total hip arthroplasty in chronic dialysis patients in the United States.

    Science.gov (United States)

    Abbott, Kevin C; Bucci, Jay R; Agodoa, Lawrence Y

    2003-01-01

    The national incidence of and factors associated with total hip arthroplasty (THA) in chronic dialysis patients has never been reported. We therefore performed an historical cohort study of 375,857 chronic dialysis patients listed in the 2000 United States Renal Data System between 1 April 1995 and 31 December 1999 and followed-up until 14 May 2000. Primary outcomes were associations with hospitalizations for a primary discharge code of THA (ICD9 procedure code 81.51x) after initiation of dialysis. Dialysis patients had a cumulative incidence of THA of 35 episodes/10,000 person-years, compared to 5.3/10,000 in the general population. The leading indication for THA was osteoarthritis of the hip and pelvis (58% of cases). However, the strongest risk factor for THA in dialysis patients was end-stage renal disease (ESRD) due to systemic lupus erythematosus (SLE, adjusted rate ratio (ARR), 6.80, 95% CI 4.62-10.03, in whom avascular necrosis of the hip was the most common indication, 68.4%). The database did not include information on use of corticosteroids. Diabetic recipients were significantly less likely to receive THA, as were males, and African Americans. Mortality after THA was 0.25% at thirty days and 30% at three years, not significantly different from the expected mortality of dialysis, adjusted for comorbidity. The most common indication for THA in dialysis patients is osteoarthritis of the hip, similar to the general population. Patients with SLE are more likely to receive THA which is well tolerated and not associated with increased mortality in this population, perhaps reflecting selection bias due to appropriate screening for this elective procedure.

  19. Comparison of complications in transtrochanteric and anterolateral approaches in primary total hip arthroplasty.

    LENUS (Irish Health Repository)

    Cashman, James P

    2008-11-01

    Three surgical approaches to primary total hip arthroplasty (THA) have been in use since Charnley popularized the transtrochanteric approach. This study was designed to examine the difference in morbidity between the transtrochanteric approach and the anterolateral approach in primary THA. Information on 891 patients who underwent primary THA performed by a single surgeon was collected prospectively between 1998 and 2003 using a modified SF-36 form, preoperatively, intraoperatively, and at 3 months postoperatively. The transtrochanteric group had higher morbidity and more patients who were dissatisfied with their THA. There was a greater range of motion in the anterolateral group.

  20. Incidence of Ceramic Liner Malseating After Ceramic-on-Ceramic Total Hip Arthroplasty Associated With Osteolysis: A 5- to 15-Year Follow-Up Study.

    Science.gov (United States)

    Higuchi, Yoshitoshi; Hasegawa, Yukiharu; Komatsu, Daigo; Seki, Taisuke; Ishiguro, Naoki

    2017-05-01

    The aim of our study was to evaluate the clinical and radiographic outcomes of malseating of the acetabular liner in ceramic-on-ceramic total hip arthroplasty (THA). Outcomes for 160 ceramic-on-ceramic THAs, contributed by 116 women and 39 men, were evaluated. Clinical and radiographic measurements were obtained over a 5- to 15-year follow-up for analysis. Liner malseating was identified in 20% of cases. Outcomes for 32 cases with liner malseating (group A) were compared to outcomes for 128 joints with correct liner seating (group B). The Harris hip score at the last follow-up was 90.1 for group A and 89.6 for group B. Osteolysis was identified in 5 cases in group A (15.6%), compared to 3 cases in group B (P ceramic fracture, audible squeaking, loosening of components, and revision THA. The mean annual liner wear rate was comparable between groups, 0.0045 mm/y for group A and 0.0039 mm/y for group B. The 10-year Kaplan-Meier survivorship, based on an end point of revision THA, was 100% for group A and 99.0% for group B. Over a moderate-length follow-up of 5-15 years, malseating of the acetabular liner was not associated with negative clinical outcomes or THA survivorship. Malseating did increase the incidence of osteolysis, a risk factor for adverse effects. Long-term follow-up studies are needed to fully quantify the effects of malseating of the acetabular liner. Copyright © 2016 Elsevier Inc. All rights reserved.