WorldWideScience

Sample records for respondent-level building conditions

  1. The acquisition of conditioned responding.

    Science.gov (United States)

    Harris, Justin A

    2011-04-01

    This report analyzes the acquisition of conditioned responses in rats trained in a magazine approach paradigm. Following the suggestion by Gallistel, Fairhurst, and Balsam (2004), Weibull functions were fitted to the trial-by-trial response rates of individual rats. These showed that the emergence of responding was often delayed, after which the response rate would increase relatively gradually across trials. The fit of the Weibull function to the behavioral data of each rat was equaled by that of a cumulative exponential function incorporating a response threshold. Thus, the growth in conditioning strength on each trial can be modeled by the derivative of the exponential--a difference term of the form used in many models of associative learning (e.g., Rescorla & Wagner, 1972). Further analyses, comparing the acquisition of responding with a continuously reinforced stimulus (CRf) and a partially reinforced stimulus (PRf), provided further evidence in support of the difference term. In conclusion, the results are consistent with conventional models that describe learning as the growth of associative strength, incremented on each trial by an error-correction process.

  2. Analysis Thermal Comfort Condition in Complex Residential Building, Case Study: Chiangmai, Thailand

    Science.gov (United States)

    Juangjandee, Warangkana

    2017-10-01

    Due to the increasing need for complex residential buildings, it appears that people migrate into the high-density urban areas because the infrastructural facilities can be easily found in the modern metropolitan areas. Such rapid growth of urbanization creates congested residential buildings obstructing solar radiation and wind flow, whereas most urban residents spend 80-90% of their time indoor. Furthermore, the buildings were mostly built with average materials and construction detail. This causes high humidity condition for tenants that could promote mould growth. This study aims to analyse thermal comfort condition in complex residential building, Thailand for finding the passive solution to improve indoor air quality and respond to local conditions. The research methodology will be in two folds: 1) surveying on case study 2) analysis for finding the passive solution of reducing humidity indoor air The result of the survey indicated that the building need to find passive solution for solving humidity problem, that can be divided into two ways which raising ventilation and indoor temperature including increasing wind-flow ventilation and adjusting thermal temperature, for example; improving building design and stack driven ventilation. For raising indoor temperature or increasing mean radiant temperature, daylight can be passive solution for complex residential design for reducing humidity and enhance illumination indoor space simultaneous.

  3. Smart buildings: Energy efficient conditioning of building occupants

    NARCIS (Netherlands)

    Zeiler, W.; Houten, van M.A.; Boxem, G.; Vehler, R.; Verhoeven, M.; Fremouw, M.

    2009-01-01

    To further optimize energy performance of buildings, intelligent building control offers new possibilities. Intelligent Software Agents (ISA) can be implemented at different levels of building automation. Individual agents for individual climate control for each user of the building in combination

  4. A THEORETICAL HEAT ANALYSIS OF BUILDINGS IN SUMMER CONDITION

    Directory of Open Access Journals (Sweden)

    R. Tuğrul OĞULATA

    1997-01-01

    Full Text Available It is possible to achive the bio-climatical comfort is buildings by setting the indoor temperature at certain level at which the people feels himself comfortable. The indoor temperature changing with the summer-winter climate conditions and with the building materials should always be around desirable level. Therefore, the variation of indoor temperature depending on the natural and artifical cooling and heating of building materials, within the range of design, is becoming so important. For this reason, in this investigation, the variation of indoor temperature has been analysed considering the variation of heat gain by convection, radiation and infiltration, the heat capacity of materials used in building including the outdoor and the temperature of outer ambient. In addition to this, the variation of indoor temperature with time has been computed under the condition that whether the cooling source exist or not. For this purpose, the heat gains, the indoor and outer temperature, the capacity of cooling system and solar radiation have been expressed analyticaly by transforming them into Fourier series.

  5. The Impact of School Building Conditions on Student Absenteeism in Upstate New York

    Science.gov (United States)

    Hwang, Syni-An; Fitzgerald, Edward F.; Kielb, Christine; Lin, Shao

    2010-01-01

    Objectives. We investigated Upstate New York school building conditions and examined the associations between school absenteeism and building condition problems. Methods. We merged data from the 2005 Building Condition Survey of Upstate New York schools with 2005 New York State Education Department student absenteeism data at the individual school level and evaluated associations between building conditions and absenteeism at or above the 90th percentile. Results. After adjustment for confounders, student absenteeism was associated with visible mold (odds ratio [OR] = 2.22; 95% confidence interval [CI] = 1.34, 3.68), humidity (OR = 3.07; 95% CI = 1.37, 6.89), poor ventilation (OR = 3.10; 95% CI = 1.79, 5.37), vermin (OR = 2.23; 95% CI = 1.32, 3.76), 6 or more individual building condition problems (OR = 2.97; 95% CI = 1.84, 4.79), and building system or structural problems related to these conditions. Schools in lower socioeconomic districts and schools attended by younger students showed the strongest associations between poor building conditions and absenteeism. Conclusions. We found associations between student absenteeism and adverse school building conditions. Future studies should confirm these findings and prioritize strategies for school condition improvements. PMID:20634471

  6. Mecamylamine, dihydro-β-erythroidine, and dextromethorphan block conditioned responding evoked by the conditional stimulus effects of nicotine

    Science.gov (United States)

    Struthers, Amanda M.; Wilkinson, Jamie L.; Dwoskin, Linda P.; Crooks, Peter A.; Bevins, Rick A.

    2009-01-01

    Current smokers express the desire to quit. However, the majority find it difficult to remain abstinent. As such, research efforts continually seek to develop more effective treatment. One such area of research involves the interoceptive stimulus effects of nicotine as either a discriminative stimulus in an operant drug discrimination task, or more recently as a conditional stimulus (CS) in a discriminated goal-tracking task. The present work investigated the potential role nicotinic acetylcholine receptors in the CS effects of nicotine (0.4 mg/kg) using antagonists with differential selectivity for β2*, α7*, α6β2*, and α3β4* receptors. Methyllycaconitine (MLA) had no effect on nicotine-evoked conditioned responding. Mecamylamine and dihydro-β-erythroidine (DHβE) dose dependently blocked responding evoked by the nicotine CS. In a time-course assessment of mecamylamine and DHβE, each blocked conditioned responding when given 5 min before testing and still blocked conditioned responding when administered 200 min before testing. Two novel bis-picolinium analogs (N, N’-(3, 3′-(dodecan-1,12-diyl)-bis-picolinium dibromide [bPiDDB], and N, N’-(decan-1,10-diyl)-bis-picolinium diiodide [bPiDI]) did not block nicotine-evoked conditioned responding. Finally, pretreatment with low dose combinations of mecamylamine, dextromethorphan, and/or bupropion were used to target α3β4* receptors. No combination blocked conditioned responding evoked by the training dose of nicotine. However, a combination of mecamylamine and dextromethorphan partially blocked nicotine-evoked conditioned responding to a lower dose of nicotine (0.1 mg/kg). These results indicate that β2* and potentially α3β4* nicotinic acetylcholine receptors play a role in the CS effects of nicotine and are potential targets for the development of nicotine cessation aids. PMID:19778551

  7. Moisture conditions in buildings

    DEFF Research Database (Denmark)

    Rode, Carsten

    2012-01-01

    Growth of mould requires the presence of moisture at a certain high level. In a heated indoor environment such moisture levels occur only if there is a reason for the moisture supply. Such moisture can come from the use of the building, because of malfunctioning constructions, or it can be the re......Growth of mould requires the presence of moisture at a certain high level. In a heated indoor environment such moisture levels occur only if there is a reason for the moisture supply. Such moisture can come from the use of the building, because of malfunctioning constructions, or it can...

  8. Repeated Activation of a CS-US-Contingency Memory Results in Sustained Conditioned Responding.

    Science.gov (United States)

    Joos, Els; Vansteenwegen, Debora; Vervliet, Bram; Hermans, Dirk

    2013-01-01

    Individuals seem to differ in conditionability, i.e., the ease by which the contingent presentation of two stimuli will lead to a conditioned response. In contemporary learning theory, individual differences in the etiology and maintenance of anxiety disorders are, among others, explained by individual differences in temperamental variables (Mineka and Zinbarg, 2006). One such individual difference variable is how people process a learning experience when the conditioning stimuli are no longer present. Repeatedly thinking about the conditioning experience, as in worry or rumination, might prolong the initial (fear) reactions and as such, might leave certain individuals more vulnerable to developing an anxiety disorder. However, in human conditioning research, relatively little attention has been devoted to the processing of a memory trace after its initial acquisition, despite its potential influences on subsequent performance. Post-acquisition processing can be induced by mental reiteration of a conditioned stimulus-unconditioned stimulus (CS-US)-contingency. Using a human conditioned suppression paradigm, we investigated the effect of repeated activations of a CS-US-contingency memory on the level of conditioned responding at a later test. Results of three experiments showed more sustained responding to a "rehearsed" CS+ as compared to a "non-rehearsed" CS+. Moreover, the second experiment showed no effect of rehearsal when only the CS was rehearsed instead of the CS-US-contingency. The third experiment demonstrated that mental CS-US-rehearsal has the same effect regardless of whether it was cued by the CS and a verbal reference to the US or by a neutral signal, making the rehearsal "purely mental." In sum, it was demonstrated that post-acquisition activation of a CS-US-contingency memory can impact conditioned responding, underlining the importance of post-acquisition processes in conditioning. This might indicate that individuals who are more prone to mentally

  9. Repeated Activation of a CS-US-Contingency Memory Results in Sustained Conditioned Responding

    Science.gov (United States)

    Joos, Els; Vansteenwegen, Debora; Vervliet, Bram; Hermans, Dirk

    2013-01-01

    Individuals seem to differ in conditionability, i.e., the ease by which the contingent presentation of two stimuli will lead to a conditioned response. In contemporary learning theory, individual differences in the etiology and maintenance of anxiety disorders are, among others, explained by individual differences in temperamental variables (Mineka and Zinbarg, 2006). One such individual difference variable is how people process a learning experience when the conditioning stimuli are no longer present. Repeatedly thinking about the conditioning experience, as in worry or rumination, might prolong the initial (fear) reactions and as such, might leave certain individuals more vulnerable to developing an anxiety disorder. However, in human conditioning research, relatively little attention has been devoted to the processing of a memory trace after its initial acquisition, despite its potential influences on subsequent performance. Post-acquisition processing can be induced by mental reiteration of a conditioned stimulus-unconditioned stimulus (CS-US)-contingency. Using a human conditioned suppression paradigm, we investigated the effect of repeated activations of a CS-US-contingency memory on the level of conditioned responding at a later test. Results of three experiments showed more sustained responding to a “rehearsed” CS+ as compared to a “non-rehearsed” CS+. Moreover, the second experiment showed no effect of rehearsal when only the CS was rehearsed instead of the CS-US-contingency. The third experiment demonstrated that mental CS-US-rehearsal has the same effect regardless of whether it was cued by the CS and a verbal reference to the US or by a neutral signal, making the rehearsal “purely mental.” In sum, it was demonstrated that post-acquisition activation of a CS-US-contingency memory can impact conditioned responding, underlining the importance of post-acquisition processes in conditioning. This might indicate that individuals who are more prone

  10. Repeated activation of a CS-US-contingency memory results in sustained conditioned responding

    Directory of Open Access Journals (Sweden)

    Els eJoos

    2013-05-01

    Full Text Available Individuals seem to differ in conditionability, i.e., the ease by which the contingent presentation of two stimuli will lead to a conditioned response. In contemporary learning theory, individual differences in the etiology and maintenance of anxiety disorders are, among others, explained by individual differences in temperamental variables (Mineka & Zinbarg, 2006. One such individual difference variable is how people process a learning experience when the conditioning stimuli are no longer present. Repeatedly thinking about the conditioning experience, as in worry or rumination, might prolong the initial (fear reactions and as such, might leave certain individuals more vulnerable to developing an anxiety disorder.However, in human conditioning research, relatively little attention has been devoted to the processing of a memory trace after its initial acquisition, despite its potential influences on subsequent performance. Post-acquisition processing can be induced by mental reiteration of a CS-US-contingency. Using a human conditioned suppression paradigm, we investigated the effect of repeated activations of a CS-US-contingency memory on the level of conditioned responding at a later test. Results of three experiments showed more sustained responding to a ‘rehearsed’ CS+ as compared to a ‘non-rehearsed’ CS+. Moreover, the second experiment showed no effect of rehearsal when only the CS was rehearsed instead of the CS-US-contingency. The third experiment demonstrated that mental CS-US-rehearsal has the same effect regardless of whether it was cued by the CS and a verbal reference to the US or by a neutral signal, making the rehearsal ‘purely mental’. In sum, it was demonstrated that post-acquisition activation of a CS-US-contingency memory can impact conditioned responding, underlining the importance of post-acquisition processes in conditioning. This might indicate that individuals who are more prone to mentally rehearse

  11. Building Condition and Suitability Evaluation Manual.

    Science.gov (United States)

    MGT of America, Inc., Tallahassee, FL.

    This educational facility evaluation manual contains the overall building condition rating form and the supporting check sheets which have been field tested in several states and, where appropriate, modified for use in the Idaho School Facilities Needs Assessment. The exterior building condition form examines the foundation, structure, walls,…

  12. Nucleus accumbens core and shell are necessary for reinforcer devaluation effects on Pavlovian conditioned responding

    Directory of Open Access Journals (Sweden)

    Teghpal eSingh

    2010-10-01

    Full Text Available The nucleus accumbens (NA has been hypothesized to be part of a circuit in which cue-evoked information about expected outcomes is mobilized to guide behavior. Here we tested this hypothesis using a Pavlovian reinforcer devaluation task, previously applied to assess outcome-guided behavior after damage to regions such as the orbitofrontal cortex and amygdala that send projections to NA. Rats with sham lesions or neurotoxic lesions of either the core or shell subdivision of NA were trained to associate a 10 sec CS+ with delivery of three food pellets. After training, half of the rats in each lesion group received food paired with illness induced by LiCl injections; the remaining rats received food and illness unpaired. Subsequently, responding to the CS+ was assessed in an extinction probe test. Both sham and lesioned rats conditioned to the CS+ and formed a conditioned taste aversion. However only sham rats reduced their conditioned responding as a result of reinforcer devaluation; devalued rats with lesions of either core or shell showed levels of responding that were similar to lesioned, non-devalued rats. This impairment was not due to the loss of motivational salience conferred to the CS+ in lesioned rats as both groups responded similarly for the cue in conditioned reinforcement testing. These data suggest that NA core and shell are part of a circuit necessary for the use of cue-evoked information about expected outcomes to guide behavior.

  13. Effects of sucrose concentration and water deprivation on Pavlovian conditioning and responding for conditioned reinforcement.

    Science.gov (United States)

    Tabbara, Rayane I; Maddux, Jean-Marie N; Beharry, Priscilla F; Iannuzzi, Jessica; Chaudhri, Nadia

    2016-04-01

    An appetitive Pavlovian conditioned stimulus (CS) can predict an unconditioned stimulus (US) and acquire incentive salience. We tested the hypothesis that US intensity and motivational state of the subject would influence Pavlovian learning and impact the attribution of incentive salience to an appetitive Pavlovian CS. To this end, we examined the effects of sucrose concentration and water deprivation on the acquisition of Pavlovian conditioning and responding for a conditioned reinforcer. Male Long-Evans rats (Harlan; 220-240 g) receiving 3% (3S) or 20% (20S) sucrose were either non-water deprived or given water for 1 hr per day. During Pavlovian conditioning sessions, half the rats in each concentration and deprivation condition received a 10-s CS paired with 0.2 ml of sucrose (16 trials/session; 3.2 ml/session). The remainder received unpaired CS and US presentations. Entries into a port where sucrose was delivered were recorded. Next, responding for conditioned reinforcement was tested, wherein pressing an active lever produced the CS and pressing an inactive lever had no consequences. CS-elicited port entries increased, and latency to the first CS-elicited port entry decreased across sessions in paired groups. Water deprivation augmented these effects, whereas sucrose concentration had no significant impact on behavior. Responding for conditioned reinforcement was observed in the 20S water-deprived, paired group. Thus, water deprivation can facilitate the acquisition of Pavlovian conditioning, potentially by enhancing motivational state, and a high-intensity US and a high motivational state can interact to heighten the attribution of incentive salience to an appetitive Pavlovian CS. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  14. [Biological contamination in office buildings related to ventilation/air conditioning system].

    Science.gov (United States)

    Bródka, Karolina; Sowiak, Małgorzata; Kozajda, Anna; Cyprowski, Marcin; Irena, Szadkowska-Stańczyk

    2012-01-01

    Indoor air is contaminated with microorganisms coming from both the atmospheric air and sources present in premises. The aim of this study was to analyze the concentrations of biological agents in office buildings, dependending on ventilation/air conditioning system and season. The study covered office buildings (different in the system of ventila-tion/air conditioning). Air samples for assessing the levels of inhalable dust, endotoxins and (1-->3)-beta-D-glucans, were taken at the selected stationary points of each building during summer and winter. The air was sampled for 6 h, using portable sets consisting of the GilAir 5 pump and the head filled with a filter of fiber glass. The samples for the presence of airborne bacteria and fungi were collected twice during the day using the impaction method. Average concentrations of inhalable dust, bacteria, fungi, endotoxins and (1-->3)-beta-D-glucans in office premises were 0.09 mg/m3, 6.00 x 10(2) cfu/m3, 4.59 x 10(1) cfu/m3, 0.42 ng/m3 and 3.91 ng/m3, respectively. Higher concentrations of the investigated agents were found in summer. In premises with air conditioning concentrations of airborne fungi, (1-->3)-beta-D-glucans and inhalable dust were significantly lower in winter. In summer the trend was reverse except for (1-->3)-beta-D-glucans. Concentrations of biological agents were affected by the season and the presence of air conditioning. Concentrations of inhalable dust, bacteria, fungi, endotoxins and (1-->3)-beta-D-glucans, observed inside the office buildings, were significantly higher in summer than in winter. The presence of the air conditioning system modified in various ways the levels of biological agents. Its influence was greater on the concentration of fungi and (1-->3)-beta-D-glucans than on that of bacteria and endotoxins.

  15. Climate conditions in bedded confinement buildings

    Science.gov (United States)

    Confinement buildings are utilized for finishing cattle to allow more efficient collection of animal waste and to buffer animals against adverse climatic conditions. Environmental data were obtained from a 29 m wide x 318 m long bedded confinement building with the long axis oriented east to west. T...

  16. Environmental Conditions and Occupant Perceptions in European Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Stoops, J.L. [Chalmers Univ. of Tech., Goeteborg (Sweden). Dept. of Building Services Engineering

    2003-03-01

    This is a preliminary report regarding a portion of the environmental conditions and occupant comfort perceptions from a five nation, 26 building European field data collection effort. Approximately 1,000 participants were involved in this project which included twelve monthly visits to each building. Climate, building and cultural variation will be illustrated for the five countries involved - France, Greece, Portugal, Sweden and the United Kingdom (UK). Each country used identical instrumentation; questionnaires and experimental protocols imbedded in a custom hardware/software system. The comfort survey was based on the ASHRAE model. The physical measurements included air temperature, globe temperature, relative humidity, air movement, CO{sub 2}, light, and sound levels. Where possible, connections and explanations between variables are made. Potential energy and policy ramifications are illustrated. (The publication includes two reports from EU JOULE III projects JOE3CT970066 'Smart controls and thermal comfort project)

  17. An approach to separating the levels of hierarchical structure building in language and mathematics.

    Science.gov (United States)

    Makuuchi, Michiru; Bahlmann, Jörg; Friederici, Angela D

    2012-07-19

    We aimed to dissociate two levels of hierarchical structure building in language and mathematics, namely 'first-level' (the build-up of hierarchical structure with externally given elements) and 'second-level' (the build-up of hierarchical structure with internally represented elements produced by first-level processes). Using functional magnetic resonance imaging, we investigated these processes in three domains: sentence comprehension, arithmetic calculation (using Reverse Polish notation, which gives two operands followed by an operator) and a working memory control task. All tasks required the build-up of hierarchical structures at the first- and second-level, resulting in a similar computational hierarchy across language and mathematics, as well as in a working memory control task. Using a novel method that estimates the difference in the integration cost for conditions of different trial durations, we found an anterior-to-posterior functional organization in the prefrontal cortex, according to the level of hierarchy. Common to all domains, the ventral premotor cortex (PMv) supports first-level hierarchy building, while the dorsal pars opercularis (POd) subserves second-level hierarchy building, with lower activation for language compared with the other two tasks. These results suggest that the POd and the PMv support domain-general mechanisms for hierarchical structure building, with the POd being uniquely efficient for language.

  18. Relationship between Quality of Building Maintenance System and Occupant Satisfaction for Office Buildings

    Directory of Open Access Journals (Sweden)

    Hamid A.H.A

    2014-03-01

    Full Text Available Buildings will be weary, decaying and dirty as time goes by; but with highquality maintenance management we can prolong the life-span of building, provide building services and keep the building performance at its ultimate level. The importance of carrying out a systematic and routine maintenance is to conserve building performance. However, this task is often neglected due to various factors including misunderstanding the needs of the maintenance works and lack of budget allocation. This paper highlights the current practice of maintenance management that are being implemented in 6 office buildings located in Kuala Lumpur, Johor, Kedah and Pulau Pinang. Using the responses of questionnaire answered by 150 respondents employed from these selected offices, personal interviews and visual inspection the following findings were made: the occupants were satisfied with the maintenance management of their buildings elements and the delivery characteristics of maintenance works. Visual inspection however showed that some elements are not in a good condition. In conclusion, some recommendations are made to improve the existing system including the establishment of a maintenance plan, selection of experienced contractors and the provision of a service desk.

  19. Conditioning of low level radioactive wastes, spent radiation sources and their transport at the interim storage building of the Institute of Nuclear Physics in Albania

    International Nuclear Information System (INIS)

    Qafmolla, L.

    2000-01-01

    Aspects of treatment and management of radioactive wastes resulting from the use of radiation sources and radioisotopes in research, medicine and industry, are described. The methods applied for the conditioning of low-level radioactive wastes and spent radiation sources are simple. Solid radioactive wastes with low-level activity, after accumulation, minimization, segregation and measurement, are burned or compressed in a simple compactor of the PGS type. Spent radiation sources are placed into 200 l drums, are cemented and conditioned. Conditioned drums from the Radiation Protection Division of the Institute of Nuclear Physics (INP), which is the responsible Institution for the treatment and management of radioactive wastes in Albania, are transported to the interim storage building of the Institute of Nuclear Physics in Tirana. Work to construct a new building for treatment and management of radioactive wastes and spent radiation sources within the territory of INP is underway. Funds have been allocated accordingly: based on the Law No. 8025 of 25.11.1995, it is the Albanian Government's responsibility to finance activities concerned with the treatment and management of radioactive wastes generating from the use of ionizing radiation in science, medicine and industry in the country. (author)

  20. Base level Investigation in various buildings and corresponding effective factors

    Directory of Open Access Journals (Sweden)

    Mohsen Tehranizadeh

    2017-07-01

    Full Text Available Base level is one of the important parameters in determining the seismic force and preliminary design of structural sections. Base level, According to 2800 seismic regulations, in cases which the basement perimeter is executed with reinforced concrete walls integrated by structure, in addition with surrounding dense soil; set top of basement walls. The critical issue involved in determining base level is horizontal motion of the land. Usually horizontal movement of the Earth is transferred by shear and friction between the edges of the basement walls and foundation, also this process is completed by soil friction between underside of slabs and shallow. Different conditions such as non-same elevated foundations, soil type around building, soil-structure interaction and type of foundation are impressive on location of base level. Other factors including retaining wall openings in basement, basement floors and soil characteristics around the base structures affect base level coordination. As regards there is cleared definition for base level in different regulation all around the world, sometimes engineers cannot comprehend main purpose correctly, or concepts occasionally are interpreted inaccurately. When structure conditions little different from what normally there is, for example, buildings on slope, or structures on deep foundation such as piles, often experts are conflicted by finding location of base level in this status. In this paper investigations about base level in the past years expressed and studied, also, important issues around them are discussed.

  1. Proposed strategies for designing sustainable high-rise apartment buildings in Ho Chi Minh City responding to critical urban issues

    Science.gov (United States)

    Truong, Nguyen Hoang Long; Huan Giang, Ngoc; Binh Duong, Trong

    2018-03-01

    This paper aims at finding practical strategies for designing sustainable high-rise apartment buildings in Ho Chi Minh City responding to varied municipal issues. Two steps are made. Step-1 identifies the critical issues of Ho Chi Minh City which are associated with high-rise apartment building projects. Step-2 finds potential and applicable strategies which are solutions for the critical issues in Step-1 with reference of seven selected assessment methods. The study finds the set of 58 strategies applicable to designing sustainable high-rise apartment buildings in Ho Chi Minh City.

  2. Locating room air-conditioners at floor level for energy saving in residential buildings

    International Nuclear Information System (INIS)

    Gao, C.F.; Lee, W.L.; Chen Hua

    2009-01-01

    Residential air-conditioning becomes a common feature in our daily life. They are typically installed at high level known as ceiling-based system (CAC). With the increasing use of floor-based air-conditioning system in commercial buildings for energy saving, it is proposed in this study to locate a top discharge/front return air-conditioner at floor level to resemble a floor-based air-conditioning system (FAC) to curb energy use in residential buildings. Given the concerns about draught discomfort and thermal stratification associated with floor-based air-conditioning systems, the objective of this study is to evaluate the air distribution performance and to quantify the possible energy benefits. Bedroom was chosen as a sensitive case for detailed air distribution performance evaluation. Experimental study, CFD simulations and energy simulations were conducted in achieving the specific objectives. CAC and FAC were installed in a bedroom-like environmental chamber for experimental study at different indoor and outdoor conditions. The air velocities and temperatures at various positions and levels inside the chamber were measured to determine the air distribution performance indices (ADPI) and airflow draft risk (DR). The cooling output, power consumption and coefficient of performance (COP) of the two units were measured and calculated for comparison. The experimental results show that ADPI of CAC and FAC are 92.3% and 84.6%, respectively. COP of FAC is 8.11% higher than CAC, and the corresponding DR are comparable. The experimental results were used to validate the CFD simulations as well as providing actual performance data for predicting the energy use of applying CAC and FAC in a case-study building. CFD simulations and draught assessment confirmed that there is no potential draught discomfort and thermal stratification associated with the use of FAC. Energy simulations predicted that the associated energy saving is 6.9%. Wider use of FAC in residential

  3. Relating Building and Classroom Conditions to Student Achievement in Virginia's Elementary Schools

    OpenAIRE

    Lanham III, James Warren

    1999-01-01

    The relationships between student achievement and a number of variables relating to building and classroom conditions in Virginia elementary schools were examined. A systematic random sample of 300 schools was selected from all elementary schools in Virginia with grades three and five. Data on building condition, classroom condition, and demographics were collected with "An Assessment of Building and Classroom Conditions in Elementary Schools in Virginia." Building prin...

  4. Radiological conditions and experiences in the TMI-2 Auxiliary Building

    International Nuclear Information System (INIS)

    Ruhter, P.E.; Zurliene, W.G.

    1988-01-01

    Although the radiological conditions following the TMI-2 accident were extraordinary, those that had a potential impact on personnel were largely confined to the Auxiliary and Fuel Handling Building. The most significant pathway was the Letdown and Make-Up and Purification System. Dose rates in some locations in the Aux/Fuel Handling Buildings were in excess of 3 mSv/s (1000 R/h) during the first few days following the accident. They decreased after three to four days and stabilized after about one week. Airborne radioactivity levels were initially due to the release of noble gases, and subsequently due to resuspension of surface contamination. During the first month, the mixture of fission products in the reactor coolant change from one of largely cesium to where the strontium and cesium were about equal in radiological importance. This created some very high beta radiation levels. The significant strontium levels caused the contamination control limit to be reduced to one-half of the pre-accident limit. 5 refs., 6 figs

  5. Conditioned Microplitis croceipes Cresson (Hymenoptera: Braconidae) detect and respond to 2,4-DNT: development of a biological sensor.

    Science.gov (United States)

    Tomberlin, Jeffery K; Tertuliano, Moukaram; Rains, Glen; Lewis, W Joe

    2005-09-01

    We examined the ability of M. croceipes to learn, detect, and respond to 2,4-DNT, which is a volatile discriminator of trinitrotoluene (TNT). The percentage of conditioned wasps to detect and respond to the various concentrations of 2,4-DNT for > or = 15 sec was measured. Significantly more of the conditioned wasps responded to the concentration of 2,4-DNT used for conditioning than other concentrations examined. Accordingly, percent conditioned wasps to respond > or = 15 sec could be used as a suitable measure to screen air samples and distinguish between samples with or without the target odorant. The data recorded in this study indicate the measured behavior could be used to estimate the concentration of target odorants. Data in this study indicate M. croceipes can detect and respond to this compound, which provide further support for its development as a biological sensor.

  6. Locating room air-conditioners at floor level for energy saving in residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    Gao, C.F.; Lee, Hua; Chen, W.L. [Department of Building Services Engineering, Hong Kong Polytechnic University, Hung Hom (China)

    2009-08-15

    Residential air-conditioning becomes a common feature in our daily life. They are typically installed at high level known as ceiling-based system (CAC). With the increasing use of floor-based air-conditioning system in commercial buildings for energy saving, it is proposed in this study to locate a top discharge/front return air-conditioner at floor level to resemble a floor-based air-conditioning system (FAC) to curb energy use in residential buildings. Given the concerns about draught discomfort and thermal stratification associated with floor-based air-conditioning systems, the objective of this study is to evaluate the air distribution performance and to quantify the possible energy benefits. Bedroom was chosen as a sensitive case for detailed air distribution performance evaluation. Experimental study, CFD simulations and energy simulations were conducted in achieving the specific objectives. CAC and FAC were installed in a bedroom-like environmental chamber for experimental study at different indoor and outdoor conditions. The air velocities and temperatures at various positions and levels inside the chamber were measured to determine the air distribution performance indices (ADPI) and airflow draft risk (DR). The cooling output, power consumption and coefficient of performance (COP) of the two units were measured and calculated for comparison. The experimental results show that ADPI of CAC and FAC are 92.3% and 84.6%, respectively. COP of FAC is 8.11% higher than CAC, and the corresponding DR are comparable. The experimental results were used to validate the CFD simulations as well as providing actual performance data for predicting the energy use of applying CAC and FAC in a case-study building. CFD simulations and draught assessment confirmed that there is no potential draught discomfort and thermal stratification associated with the use of FAC. Energy simulations predicted that the associated energy saving is 6.9%. Wider use of FAC in residential

  7. Air conditioning device for reactor buildings

    International Nuclear Information System (INIS)

    Kikuchi, Shiro.

    1982-01-01

    Purpose: To decrease the opening areas of pipe lines for an air conditioning device at the portions passing through the shielding walls of a reactor building for a FBR type reactor, as well as reduce the size of the building. Constitution: Airs in the building for containing reactor are liquefied in an air liquefying mechanism. The liquefied airs are sent by way of pipe lines to each of evaporators, wherein each of the chambers are cooled because of latent heat of evaporation and evaporated airs are released to each of the chambers. The airs released to each of the chambers are collected into an exhaust chamber and sent by way of a duct to the air liquefying mechanism and liquefied again. Since the volume of the liquefied airs may be smaller than the amount conventionally required for usual cooled airs, the pipe lines passing through the shielding walls of the building can be of smaller diameter. This can decrease the opening areas of the pipe lines at the portions passing through the walls of the shieldings and, since the opening areas are smaller, the structure of the radiation shieldings can be simplified in these portions. Further, since the space of the pipe lines in the building is reduced extremely, the size of the building can be reduced. (Moriyama, K.)

  8. Solar chimney: A sustainable approach for ventilation and building space conditioning

    Directory of Open Access Journals (Sweden)

    Lal, S.,

    2013-03-01

    Full Text Available The residential and commercial buildings demand increase with rapidly growing population. It leads to the vertical growth of the buildings and needs proper ventilation and day-lighting. The natural air ventilation system is not significantly works in conventional structure, so fans and air conditioners are mandatory to meet the proper ventilation and space conditioning. Globally building sector consumed largest energy and utmost consumed in heating, ventilation and space conditioning. This load can be reduced by application of solar chimney and integrated approaches in buildings for heating, ventilation and space conditioning. It is a sustainable approach for these applications in buildings. The authors are reviewed the concept, various method of evaluation, modelings and performance of solar chimney variables, applications and integrated approaches.

  9. Building district-level capacity for continuous improvement in maternal and newborn health.

    Science.gov (United States)

    Stover, Kim Ethier; Tesfaye, Solomon; Frew, Aynalem Hailemichael; Mohammed, Hajira; Barry, Danika; Alamineh, Lamesgin; Teshome, Abebe; Hepburn, Kenneth; Sibley, Lynn M

    2014-01-01

    The Maternal and Newborn Health in Ethiopia Partnership (MaNHEP) adapted a collaborative improvement strategy to develop woreda (district) leadership capacity to support and facilitate continuous improvement of community maternal and neonatal health (CMNH) and to provide a model for other woredas, dubbed "lead" woredas. Community-level quality improvement (QI) teams tested solutions to improve CMNH care supported by monthly coaching and regular meetings to share experiences. This study examines the extent of the capacity built to support continuous improvement in CMNH care. Surveys and in-depth interviews assessed the extent to which MaNHEP developed improvement capacity. A survey questionnaire evaluated woreda culture, leadership support, motivation, and capacity for improvement activities. Interviews focused on respondents' understanding and perceived value of the MaNHEP improvement approach. Bivariate analyses and multivariate linear regression models were used to analyze the survey data. Interview transcripts were organized by region, cadre, and key themes. Respondents reported significant positive changes in many areas of woreda culture and leadership, including involving a cross-section of community stakeholders (increased from 3.0 to 4.6 on 5-point Likert scale), using improvement data for decision making (2.8-4.4), using locally developed and tested solutions to improve CMNH care (2.5-4.3), demonstrating a commitment to improve the health of women and newborns (2.6-4.2), and creating a supportive environment for coaches and QI teams to improve CMNH (2.6-4.0). The mean scores for capacity were 3.7 and higher, reflecting respondents' agreement that they had gained capacity in improvement skills. Interview respondents universally recognized the capacity built in the woredas. The themes of community empowerment and focused improvement emerged strongly from the interviews. MaNHEP was able to build capacity for continuous improvement and develop lead woredas. The

  10. Adopting the EU sustainable performance scheme Level(s) in the Danish building sector

    DEFF Research Database (Denmark)

    Kanafani, Kai; Rasmussen, Freja Nygaard; Zimmermann, Regitze Kjær

    2018-01-01

    to life cycle assessment (LCA) requirements within the Level(s) scheme. As a measure for the Danish building sector’s LCA practice, the specifications for LCAbyg, the official Danish building LCA tool, is used. In 2017, the European commission’s Joint Research Centre has launched Level(s) as a vo...

  11. Modelling the distribution of 222Rn concentration in a multi level, general purpose building

    International Nuclear Information System (INIS)

    Toro, Laszlo; Noditi, Mihaela; Gheorghe, Raluca; Gheorghe, Dan

    2008-01-01

    The importance of 222 Rn (radon) in the indoor air related to the exposure form natural sources is relatively well documented. About 30% of the individual effective dose from natural sources is coming from the inhalation of 222 Rn and his short lived daughters. In unfavorable conditions given by the soil porosity and the existence of upward air movement in the soil there is a possibility to have unusually high radon concentration in houses even on soil with 'normal' 226 Ra content. Some construction solutions (high indoor spaces) should generate a significant indoor-outdoor negative pressure differences and consequently upward air currents (stack effect) which will facilitate the entrance of radon in the building. This effect will multiply the possibility of migration of radon in the building. The difficulty of the prediction of radon migration in the soil-building system increase the importance of the mathematical modelling of the behavior of radon-soil emission, infiltration and migration in the building - in areas with high radon potential. For one level simple buildings there are several models in the literature but the information regarding the multilevel building models are relatively scarce. Two different approaches used to describe the behavior of the radon gas in large (mainly high) buildings have been analyzed: Direct approach: computational fluid dynamics, solving the transport equations for the whole building (the domain of the solution of the transport and flow equations is delimited by the building envelope - the external walls); the openings (internal and external) and ventilation are defined by the boundary conditions. This approach is quite complex, the equations are solved (numerically) for highly inhomogeneous medium but is based on the fundamental processes governing the transport. In the same time it gives the possibility to obtain a concentration pattern in every part of the building. Multi-zone approach treating the building as interconnected

  12. Fear conditioning following a unilateral anterior temporal lobectomy: reduced autonomic responding and stimulus contingency knowledge.

    Science.gov (United States)

    Coppens, Evelien; van Paesschen, Wim; Vandenbulcke, Mathieu; Vansteenwegen, Debora

    2010-03-01

    Animal research demonstrated that during fear conditioning the amygdala plays a central role in forming an association between the conditioned stimulus (CS) and the unconditioned stimulus (US). Lesion studies conducted in patients who underwent a unilateral anterior temporal lobe resection, however; yielded contradictory findings. To date, it remains unclear whether amygdala damage only affects fear-conditioned startle responding or impairs both the latter and fear-conditioned skin conductance responding (SCR). Moreover inconsistency exists regarding the preservation of contingency knowledge in amygdala-damaged patients. In the current study, a differential fear conditioning task was presented to a unilaterally amygdala-damaged patient group and a healthy control group, recording fear-potentiated startle responses along with SCRs. Retrospectively, the valence of the CSs and contingency awareness was assessed. Unlike the control group, unilaterally amygdala-damaged patients showed neither in their SCRs nor in their valence ratings an effect of fear conditioning. The startle data, however, yielded in none of the two test groups fear-conditioned responding. Finally, considerably fewer patients (37.5%) than controls (95%) acquired correct memory of the presented contingency. Based on these findings we concluded that the fear conditioning impairment in amygdala-damaged patients was not restricted to SCRs, but also affected valence ratings and memory of the presented contingency. A broader theory of the amygdala as relevance detector is proposed in order to account for the diverse neurological findings obtained so far.

  13. Comparison of methods used in European countries to assess buildings' condition

    NARCIS (Netherlands)

    Vilhena, A.; Costa Branco De Oliveira Pedro, J.A.; De Brito, J.

    2011-01-01

    This paper presents a comparative analysis of methods used in European countries to assess buildings’ condition. The following methods were compared: a Portuguese method to assess buildings condition, an English housing health and safety rating system, a French method to assess buildings that may be

  14. Damage Level Prediction of Reinforced Concrete Building Based on Earthquake Time History Using Artificial Neural Network

    Directory of Open Access Journals (Sweden)

    Suryanita Reni

    2017-01-01

    Full Text Available The strong motion earthquake could cause the building damage in case of the building not considered in the earthquake design of the building. The study aims to predict the damage-level of building due to earthquake using Artificial Neural Networks method. The building model is a reinforced concrete building with ten floors and height between floors is 3.6 m. The model building received a load of the earthquake based on nine earthquake time history records. Each time history scaled to 0,5g, 0,75g, and 1,0g. The Artificial Neural Networks are designed in 4 architectural models using the MATLAB program. Model 1 used the displacement, velocity, and acceleration as input and Model 2 used the displacement only as the input. Model 3 used the velocity as input, and Model 4 used the acceleration just as input. The output of the Neural Networks is the damage level of the building with the category of Safe (1, Immediate Occupancy (2, Life Safety (3 or in a condition of Collapse Prevention (4. According to the results, Neural Network models have the prediction rate of the damage level between 85%-95%. Therefore, one of the solutions for analyzing the structural responses and the damage level promptly and efficiently when the earthquake occurred is by using Artificial Neural Network

  15. Building occupancy diversity and HVAC (heating, ventilation, and air conditioning) system energy efficiency

    International Nuclear Information System (INIS)

    Yang, Zheng; Ghahramani, Ali; Becerik-Gerber, Burcin

    2016-01-01

    Approximately forty percent of total building energy consumption is attributed to HVAC (heating, ventilation, and air conditioning) systems that aim to maintain healthy and comfortable indoor environments. An HVAC system is a network with several subsystems, and there exist heat transfer and balance among the zones of a building, as well as heat gains and losses through a building's envelope. Diverse occupancy (diversity in terms of when and how occupants occupy a building) in spaces could result in increase of loads that are not actual demands for an HVAC system, leading into inefficiencies. This paper introduces a framework to quantitatively evaluate the energy implications of occupancy diversity at the building level, where building information modeling is integrated to provide building geometries, HVAC system layouts, and spatial information as inputs for computing potential energy implications if occupancy diversity were to be eliminated. An agglomerate hierarchical clustering-based iterative evaluation algorithm is designed for iteratively eliminating occupancy diversity. Whole building energy simulations for a real-world building, as well as virtual reference buildings demonstrate that the proposed framework could effectively quantify the HVAC system energy efficiency affected by occupancy diversity and the framework is generalizable to different building geometries, layouts, and occupancy diversities. - Highlights: • Analyze relationships between occupancy diversity and HVAC energy efficiency. • Integrate BIM for quantifying energy implications of occupancy diversity. • Demonstrate the effectiveness and generalizability of iterative evaluation algorithm. • Improve agglomerative hierarchical clustering process using heap data structure.

  16. Prediction of thermal sensation in non-air-conditioned buildings in warm climates

    DEFF Research Database (Denmark)

    Fanger, Povl Ole; Toftum, Jørn

    2002-01-01

    The PMV model agrees well with high-quality field studies in buildings with HVAC systems, situated in cold, temperate and warm climates, studied during both summer and winter. In non-air-conditioned buildings in warm climates, occupants may sense the warmth as being less severe than the PMV...... predicts. The main reason is low expectations, but a metabolic rate that is estimated too high can also contribute to explaining the difference. An extension of the PMV model that includes an expectancy factor is introduced for use in non-air-conditioned buildings in warm climates. The extended PMV model...... agrees well with quality field studies in non-air-conditioned buildings of three continents....

  17. Do building wakes increase ground level concentrations?

    International Nuclear Information System (INIS)

    Taylor, T.J.; Melbourne, W.H.

    1996-01-01

    As part of the EPRI Plume Rise and Downwash Project to develop and evaluate new mathematical algorithms representing plume rise and downwash, physical model studies were performed on the plume dispersion from Combustion Turbine Unit 4, (CT 4), at the Jersey Central Power and Light Sayreville Generating Station, Sayreville, New Jersey. Studies were performed both in neutral and stably stratified model atmospheric boundary layer conditions with the primary objective being to determine the behavior of the combustion turbine plume under high and low ambient wind speed conditions within the wake region produced by the combustion turbine itself. Field measurements were also performed at the site and to this end a base case wind direction of β = 335 degree was chosen for both the field and model studies in an attempt to minimize the effects of other building wakes on the plume. This paper looks at the flow and dispersion characteristics with and without these large structures in the model in an attempt to explain why the differences in concentration levels occurred

  18. Air conditioning device for pool facilities in nuclear power plant buildings

    International Nuclear Information System (INIS)

    Taruishi, Yoshiaki; Ishida, Seiji.

    1981-01-01

    Purpose: To improve the temperature and humidity conditions for the working circumstance, prevent condensations on the wall surface and enable the reduction in the irradiation exposure to workers. Constitution: Air intake ports are provided on the side wall of a fuel storage pool or an equipment installation pool above the water level and connected by way of their exhaust ducts to the exhaust ducts of an air ventilation system. While on the other hand, air feed ducts having horizontally opened blowing ports and air exhaust ducts having horizontally opened exhaust ports above and in adjacent to the air feed ducts are provided on the side walls of the pool buildings at the height near the floor level. With this structure, fresh outdoor airs blown out horizontally from the blowing ports provided near the floor level can improve the temperature and humidity conditions of the working circumstance for the workers working on the floor. Further, an air clean up device is provided to the feed and exhaust systems for clean up the feed and exhaust airs. (Furukawa, Y.)

  19. Energy Saving Potential of PCMs in Buildings under Future Climate Conditions

    Directory of Open Access Journals (Sweden)

    Abdo Abdullah Ahmed Gassar

    2017-11-01

    Full Text Available Energy consumption reduction under changing climate conditions is a major challenge in buildings design, where excessive energy consumption creates an economic and environmental burden. Improving thermal performance of the buildings through support applying phase change material (PCM is a promising strategy for reducing building energy consumption under future climate change. Therefore, this study aims to investigate the energy saving potentials in buildings under future climate conditions in the humid and snowy regions in the hot continental and humid subtropical climates of the east Asia (Seoul, Tokyo and Hong Kong when various PCMs with different phase change temperatures are applied to a lightweight building envelope. Methodology in this work is implemented in two phases: firstly, investigation of energy saving potentials in buildings through inclusion of three types of PCMs with different phase temperatures into the building envelop separately and use weather file in the present (2017; and, secondly, evaluation of the effect of future climate change on the performance of PCMs by analyzing energy saving potentials of PCMs with 2020, 2050 and 2080 weather data. The results show that the inclusion of PCM into the building envelope is a promising strategy to increase the energy performance in buildings during both heating and cooling seasons in Seoul, Tokyo and Hong Kong under future climate conditions. The energy savings achieved by using PCMs in those regions are electricity savings of 4.48–8.21%, 3.81–9.69%, and 1.94–5.15%, and gas savings of 1.65–16.59%, 7.60–61.76%, and 62.07–93.33% in Seoul, Tokyo and Hong Kong, respectively, for the years 2017, 2020, 2050 and 2080. In addition, BioPCM and RUBITHERMPCM are the most efficient for improving thermal performance and saving energy in buildings in the tested regions and years.

  20. System-Level Monitoring and Diagnosis of Building HVAC System

    OpenAIRE

    Wu, Siyu

    2013-01-01

    Heating, ventilation, and air conditioning (HVAC) is an indoor environmental technology that is extensively instrumented for large-scale buildings. Among all subsystems of buildings, the HVAC system dominates the energy consumption and accounts for 57% of the energy used in U.S. commercial and residential buildings. Unfortunately, the HVAC system may fail to meet the performance expectations due to various faults, including not only complete hardware failures, but also non-optimal operations....

  1. Management of air-conditioning systems in residential buildings by using fuzzy logic

    Directory of Open Access Journals (Sweden)

    Sohair F. Rezeka

    2015-06-01

    Full Text Available There has been a rising concern in reducing the energy consumption in buildings. Heating, ventilation and air-conditioning system is the biggest consumer of energy in buildings. In this study, management of the air-conditioning system of a building for efficient energy operation and comfortable environment is investigated. The strategy used in this work depends on classifying the rooms to three different groups: very important rooms, important rooms and normal rooms. The total mass flow rate is divided between all rooms by certain percentage using a fuzzy-logic system to get the optimum performance for each room. The suggested Building Management System (BMS was found capable of keeping errors in both temperature and humidity within the acceptable limits at different operating conditions. The BMS can save the chilled/hot water flow rate and the cooling/heating capacity of rooms.

  2. Thermal and Energy Performance of Conditioned Building Due To Insulated Sloped Roof

    Science.gov (United States)

    Irwan, Suhandi Syiful; Ahmed, Azni Zain; Zakaria, Nor Zaini; Ibrahim, Norhati

    2010-07-01

    For low-rise buildings in equatorial region, the roof is exposed to solar radiation longer than other parts of the envelope. Roofs are to be designed to reject heat and moderate the thermal impact. These are determined by the design and construction of the roofing system. The pitch of roof and the properties of construction affect the heat gain into the attic and subsequently the indoor temperature of the living spaces underneath. This finally influences the thermal comfort conditions of naturally ventilated buildings and cooling load of conditioned buildings. This study investigated the effect of insulated sloping roof on thermal energy performance of the building. A whole-building thermal energy computer simulation tool, Integrated Environmental Solution (IES), was used for the modelling and analyses. A building model with dimension of 4.0 m × 4.0 m × 3.0 m was designed with insulated roof and conventional construction for other parts of the envelope. A 75 mm conductive insulation material with thermal conductivity (k-value) of 0.034 Wm-1K-1 was installed underneath the roof tiles. The building was modelled with roof pitch angles of 0° , 15°, 30°, 45°, 60° and simulated for the month of August in Malaysian climate conditions. The profile for attic temperature, indoor temperature and cooling load were downloaded and evaluated. The optimum roof pitch angle for best thermal performance and energy saving was identified. The results show the pitch angle of 0° is able to mitigate the thermal impact to provide the best thermal condition with optimum energy savings. The maximum temperature difference between insulated and non-insulted roof for attic (AtticA-B) and indoor condition (IndoorA-B) is +7.8 °C and 0.4 °C respectively with an average energy monthly savings of 3.9 %.

  3. A Study of the Relationship Between School Leadership and the Condition of School Buildings

    OpenAIRE

    Brannon, William Lee

    2000-01-01

    The purpose of this study was to examine the relationship between school leadership and the quality, condition, maintenance, improvements, and renovations of public school buildings. The first question examined the relationship between building conditions and perceptions of school board members, superintendent and central office staff, board of supervisors, and principals. The second question examined the relationship between building conditions and the financial support of leadership positio...

  4. Extension of the PMV model to non-air-conditioned building in warm climates

    DEFF Research Database (Denmark)

    Fanger, Povl Ole; Toftum, Jørn

    2002-01-01

    The PMV model agrees well with high-quality field studies in buildings with HVAC systems, situated in cold, temperate and warm climates, studied during both summer and winter. In non-air-conditioned buildings in warm climates, occupants may sense the warmth as being less severe than the PMV...... predicts. The main reason is low expectations, but a metabolic rate that is estimated too high can also contribute to explaining the difference. An extension of the PMV model that includes an expectancy factor is introduced for use in non-air-conditioned buildings in warm climates. The extended PMV model...... agrees well with quality field studies in non-air-conditioned buildings of three continents....

  5. Characteristics of radon and its progeny concentrations in air-conditioned office buildings in Tokyo

    International Nuclear Information System (INIS)

    Tokonami, S.; Furukawa, M.; Shicchi, Y.; Sanada, T.; Yamada, Y.

    2003-01-01

    A series of measurements were carried out to understand the characteristics of radon and its progeny in air-conditioned office buildings. Long-term measurements of radon were made with etched track detectors. Continuous measurements of radon and its progeny concentrations were also conducted in some buildings to study their temporal variations. The results show that radon and its progeny concentrations routinely varied along with working activities. They are generally low while people are working, due to air conditioning, whereas they rise steadily after the air conditioning stops. When considering action levels not only in homes but also workplaces, attention should be paid to annual doses from the viewpoint of radiation protection. The annual dose is generally estimated with a long-term measurement of radon concentration using a passive device such as an etched track detector. Since its reading corresponds to a long-term average concentration regardless of working hours, the annual dose will be overestimated. When comparing a real dose after considering the working hours, they differ by a factor of more than 2. (author)

  6. The effects of buildings on low-level atmospheric discharges

    International Nuclear Information System (INIS)

    Foster, P.M.; Robins, A.G.

    1985-01-01

    The building wake dispersion study undertaken by the CEGB was aimed at providing a coherent assessment of both analytical and physical modelling techniques from comparisons with full scale data obtained at an operational nuclear power station in well mixed meteorological conditions. The project was divided into three parts: (i) to develop the necessary full scale techniques for quantitative plume observations at ground level and above, (ii) to conduct a range of plume dispersion and mapping experiments at a suitable nuclear site at both full and model scales, (iii) to assess the results of (ii) and compare them with analytical modelling predictions. A dual smoke tracer and SF 6 gas tracer was chosen for the full scale trials. They were conducted at Oldbury Power Station. The complementary wind tunnel investigations were conducted in the CEGB wind tunnel. The full scale measurements provided data on the elevated plume structure and on the downwind range dependence of plume dimensions and concentration over a limited range of wind directions. Comparison with the corresponding results from the wind tunnel study was generally good. However, in the lightest winds studied (around 5 ms -1 ) differences were observed. A selection of simple analytic models was subjected to further analysis using the extensive data set from the wind tunnel study. This showed that close to the building plume behaviour was complex and produced large variations in ground level centre line concentration with varying source position and wind direction. The analytic models do not predict this but only attempt to represent the bulk behaviour. However, beyond about 10 building heights range the plume behaviour simplifies sufficiently for acceptably accurate predictions to be achieved

  7. Energy policy for integrating the building environmental performance model of an air conditioned building in a subtropical climate

    International Nuclear Information System (INIS)

    Mui, K.W.

    2006-01-01

    For an air conditioned building, the major electricity consumption is by the heating, and air conditioning (HVAC) system. As energy saving strategies may be in conflict with the criteria of indoor air quality and thermal comfort, a concept of the building environmental performance model (BEPM) has been developed to optimize energy consumption in HVAC systems without any deterioration of the indoor air quality and thermal comfort. The BEPM is divided into two main modules: the adaptive comfort temperature (ACT) module and the new demand control ventilation (nDCV) module. This study aims to enhance and prompt the conventional operation of the air side systems by incorporating temperature reset with the adaptive comfort temperature control and the new demand control ventilation system in high rise buildings in Hong Kong. A new example weather year (1991) was established as a reference to compute the energy use of HVAC systems in buildings in order to obtain more representative data for predicting annual energy consumption. A survey of 165 Hong Kong office buildings was conducted and it provided valuable information on the existing HVAC design values in different grades of private commercial buildings in Hong Kong. It was found that the actual measured values of indoor temperature were lower than the design ones. Furthermore, with the new example weather year and the integration of the BEPM into Grade A private office buildings in Hong Kong, the total energy saving of the air conditioning systems was calculated (i.e. a saving of HK$122 million in electrical consumption per year) while the thermal comfort for the occupants was also maintained

  8. Intraspecific Variation in Physiological Condition of Reef-Building Corals Associated with Differential Levels of Chronic Disturbance

    Science.gov (United States)

    Pisapia, Chiara; Anderson, Kristen; Pratchett, Morgan S.

    2014-01-01

    Even in the absence of major disturbances (e.g., cyclones, bleaching), corals are subject to high levels of partial or whole-colony mortality, often caused by chronic and small-scale disturbances. Depending on levels of background mortality, these chronic disturbances may undermine individual fitness and have significant consequences on the ability of colonies to withstand subsequent acute disturbances or environmental change. This study quantified intraspecific variations in physiological condition (measured based on total lipid content and zooxanthellae density) through time in adult colonies of two common and widespread coral species (Acropora spathulata and Pocillopora damicornis), subject to different levels of biological and physical disturbances along the most disturbed reef habitat, the crest. Marked intraspecific variation in the physiological condition of A. spathulata was clearly linked to differences in local disturbance regimes and habitat. Specifically, zooxanthellae density decreased (r2 = 26, df = 5,42, pzooxanthellae density was strongly and negatively correlated with the individual level of partial mortality (r2 = 26, df = 5,42, p<0.02, B =  −7386077, p = 0.01). Conversely, P. damicornis exhibited very limited intraspecific variation in physiological condition, despite marked differences in levels of partial mortality. This is the first study to relate intraspecific variation in the condition of corals to localized differences in chronic disturbance regimes. The next step is to ascertain whether these differences have further ramifications for susceptibility to periodic acute disturbances, such as climate-induced coral bleaching. PMID:24626395

  9. Energy performance and optimal control of air-conditioned buildings with envelopes enhanced by phase change materials

    International Nuclear Information System (INIS)

    Zhu Na; Wang Shengwei; Ma Zhenjun; Sun Yongjun

    2011-01-01

    Highlights: → Impact of PCM on the energy consumption and peak load demand as well as electricity cost of air-conditioned buildings. → Impact of load shifting control on energy consumption, peak load and electricity cost of air-conditioned PCM buildings. → Impact of demand limiting control on energy consumption, peak load and electricity cost of air-conditioned PCM buildings. → Energy/cost effects of different control strategies and use of PCM in energy-plus-demand-based pricing policy. → Energy/cost effects of different control strategies and use of PCM in time-based pricing policy. - Abstract: Studies are conducted to investigate the impacts of shape-stabilized phase change material (SSPCM) and different control strategies on the energy consumption and peak load demand as well as electricity cost of building air-conditioning systems at typical summer conditions in two climates (subtropical and dry continental climates). An office building using a typical variable air volume (VAV) air-conditioning system was selected and simulated as the reference building in this study. Its envelopes were enhanced by integrating the SSPCM layers into its walls while the air-conditioning system and other configurations of the building remained unchanged. The building system was tested under two typical weather conditions and two typical electricity pricing policies (i.e. time-based pricing and energy-plus-demand-based pricing). Test results show that the use of SSPCM in the building could reduce the building electricity cost significantly (over 11% in electricity cost reduction and over 20% in peak load reduction), under two pricing policies by using load shifting control and demand limiting control respectively. This paper presents the test results and the evaluation on the energy performance and the optimal control strategies of air-conditioned commercial buildings with envelopes enhanced by SSPCM.

  10. Improving the thermal integrity of new single-family detached residential buildings: Documentation for a regional database of capital costs and space conditioning load savings

    International Nuclear Information System (INIS)

    Koomey, J.G.; McMahon, J.E.; Wodley, C.

    1991-07-01

    This report summarizes the costs and space-conditioning load savings from improving new single-family building shells. It relies on survey data from the National Association of Home-builders (NAHB) to assess current insulation practices for these new buildings, and NAHB cost data (aggregated to the Federal region level) to estimate the costs of improving new single-family buildings beyond current practice. Space-conditioning load savings are estimated using a database of loads for prototype buildings developed at Lawrence Berkeley Laboratory, adjusted to reflect population-weighted average weather in each of the ten federal regions and for the nation as a whole

  11. Power load leveling and energy saving measures for office buildings. Power load leveling and energy saving technology for the new building of the Kobe branch of the Kansai Electric Power Co., and its effect; Office biru no denryoku fuka heijunka sho energy hosaku. Kobe shiten shinshaoku ni okeru denryoku fuka heijunka sho energy gijutsu to sono koka

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiyama, M. [Kansai Electric Power Co. Inc., Osaka (Japan)

    1999-06-10

    This paper presents power load leveling and energy saving measures for heat source, air conditioning and lighting of the new Kobe branch building. The low-temperature hot-air system adopts an ice storage system, and reduces blowing power by 12 degreesC blowing in place of normal 16 degreesC blowing, and an initial cost by duct size reduction. The continuous air conditioning system levels an initial peak load of air conditioning as compared with normal air conditioning only for working hours for buildings with large heat capacity. In addition, as power load leveling measures for the whole building, the complete heat storage system using an underground internal melting type ice storage tank is adopted. Energy saving for lighting is achieved with a dimming lighting controlling its lighting output by inverter. The following effects are expected by these new technologies: Load leveling effect of 30%, energy saving effect of 20.2% and CO{sub 2} reduction effect of 24.1%. (NEDO)

  12. First responder tracking and visualization for command and control toolkit

    Science.gov (United States)

    Woodley, Robert; Petrov, Plamen; Meisinger, Roger

    2010-04-01

    In order for First Responder Command and Control personnel to visualize incidents at urban building locations, DHS sponsored a small business research program to develop a tool to visualize 3D building interiors and movement of First Responders on site. 21st Century Systems, Inc. (21CSI), has developed a toolkit called Hierarchical Grid Referenced Normalized Display (HiGRND). HiGRND utilizes three components to provide a full spectrum of visualization tools to the First Responder. First, HiGRND visualizes the structure in 3D. Utilities in the 3D environment allow the user to switch between views (2D floor plans, 3D spatial, evacuation routes, etc.) and manually edit fast changing environments. HiGRND accepts CAD drawings and 3D digital objects and renders these in the 3D space. Second, HiGRND has a First Responder tracker that uses the transponder signals from First Responders to locate them in the virtual space. We use the movements of the First Responder to map the interior of structures. Finally, HiGRND can turn 2D blueprints into 3D objects. The 3D extruder extracts walls, symbols, and text from scanned blueprints to create the 3D mesh of the building. HiGRND increases the situational awareness of First Responders and allows them to make better, faster decisions in critical urban situations.

  13. Thermal comfort of various building layouts with a proposed discomfort index range for tropical climate.

    Science.gov (United States)

    Md Din, Mohd Fadhil; Lee, Yee Yong; Ponraj, Mohanadoss; Ossen, Dilshan Remaz; Iwao, Kenzo; Chelliapan, Shreeshivadasan

    2014-04-01

    Recent years have seen issues related to thermal comfort gaining more momentum in tropical countries. The thermal adaptation and thermal comfort index play a significant role in evaluating the outdoor thermal comfort. In this study, the aim is to capture the thermal sensation of respondents at outdoor environment through questionnaire survey and to determine the discomfort index (DI) to measure the thermal discomfort level. The results indicated that most respondents had thermally accepted the existing environment conditions although they felt slightly warm and hot. A strong correlation between thermal sensation and measured DI was also identified. As a result, a new discomfort index range had been proposed in association with local climate and thermal sensation of occupants to evaluate thermal comfort. The results had proved that the respondents can adapt to a wider range of thermal conditions.Validation of the questionnaire data at Putrajaya was done to prove that the thermal sensation in both Putrajaya and UTM was almost similar since they are located in the same tropical climate region. Hence, a quantitative field study on building layouts was done to facilitate the outdoor human discomfort level based on newly proposed discomfort index range. The results showed that slightly shaded building layouts of type- A and B exhibited higher temperature and discomfort index. The resultant adaptive thermal comfort theory was incorporated into the field studies as well. Finally, the study also showed that the DI values were highly dependent on ambient temperature and relative humidity but had fewer effects for solar radiation intensity. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Intraspecific variation in physiological condition of reef-building corals associated with differential levels of chronic disturbance.

    Directory of Open Access Journals (Sweden)

    Chiara Pisapia

    Full Text Available Even in the absence of major disturbances (e.g., cyclones, bleaching, corals are subject to high levels of partial or whole-colony mortality, often caused by chronic and small-scale disturbances. Depending on levels of background mortality, these chronic disturbances may undermine individual fitness and have significant consequences on the ability of colonies to withstand subsequent acute disturbances or environmental change. This study quantified intraspecific variations in physiological condition (measured based on total lipid content and zooxanthellae density through time in adult colonies of two common and widespread coral species (Acropora spathulata and Pocillopora damicornis, subject to different levels of biological and physical disturbances along the most disturbed reef habitat, the crest. Marked intraspecific variation in the physiological condition of A. spathulata was clearly linked to differences in local disturbance regimes and habitat. Specifically, zooxanthellae density decreased (r2 = 26, df = 5,42, p<0.02, B =  -121255, p = 0.03 and total lipid content increased (r2 = 14, df = 5,42, p = 0.01, B = 0.9, p = 0.01 with increasing distance from exposed crests. Moreover, zooxanthellae density was strongly and negatively correlated with the individual level of partial mortality (r2 = 26, df = 5,42, p<0.02, B =  -7386077, p = 0.01. Conversely, P. damicornis exhibited very limited intraspecific variation in physiological condition, despite marked differences in levels of partial mortality. This is the first study to relate intraspecific variation in the condition of corals to localized differences in chronic disturbance regimes. The next step is to ascertain whether these differences have further ramifications for susceptibility to periodic acute disturbances, such as climate-induced coral bleaching.

  15. Occupant comfort and health in green and conventional university buildings.

    Science.gov (United States)

    Hedge, A; Miller, L; Dorsey, J A

    2014-01-01

    Green building standards are significantly impacting modern construction practices. The resulting structures are more energy efficient, but their impact on occupant health has not been widely studied. To investigate a range of indoor environment and ergonomic issues in green buildings. Retrospective post-occupancy evaluation survey of 319 occupants in two Leadership in Energy and Environmental Design (LEED) certified buildings and one conventional building on a Canadian University campus. Results show that working in the LEED buildings was a generally positive experience for their health, performance, and satisfaction. However, the LEED buildings did not always receive the highest ratings for environmental conditions or for health and productivity. Respondents indicated a range of concerns with thermal conditions, office lighting, noise and their overall workstation designs and these were not always better in the green buildings. These results highlight the need for better integration of ergonomic design into green buildings and into the LEED rating system, and these implications are discussed.

  16. The Future of Air Conditioning for Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Goetzler, William [Navigant Consulting, Burlington, MA (United States); Guernsey, Matt [Navigant Consulting, Burlington, MA (United States); Young, Jim [Navigant Consulting, Burlington, MA (United States); Fujrman, Jay [Navigant Consulting, Burlington, MA (United States); Abdelaziz, Amar [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-07-01

    BTO works with researchers and industry to develop and deploy technologies that can substantially reduce energy consumption and greenhouse gas (GHG) emissions in residential and commercial buildings. Air conditioning systems in buildings contribute to GHG emissions both directly through refrigerant emissions, as well as indirectly through fossil fuel combustion for power generation. BTO promotes pre-competitive research and development on next-generation HVAC technologies that support the phase down of hydrofluorocarbon (HFC) production and consumption, as well as cost-effective energy efficiency improvements. DOE provides, with this report, a fact-based vision for the future of A/C use around the world. DOE intends for this vision to reflect a broad and balanced aggregation of perspectives. DOE brings together this content in an effort to support dialogue within the international community and help keep key facts and objectives at the forefront among the many important discussions.

  17. Thermal performance of air-conditioned office buildings constructed with inclined walls in different climates in China

    International Nuclear Information System (INIS)

    Chan, A.L.S.; Chow, T.T.

    2014-01-01

    Highlights: • A generic fully air-conditioned office building with inclined walls was modeled. • Simulations were run under climatic conditions in three modern cities in China. • Reduction in cooling load can outweigh the increase in heating load for Hong Kong. • Inclined angle of 30° is appropriate for inverted pyramidal building in Hong Kong. • Building constructed with inclined walls is not encouraged in Shanghai and Beijing. - Abstract: An inverted pyramidal building is built with inclined walls instead of the traditional vertical façades. In terms of thermal performance, an inverted pyramidal building can provide a self-shading effect against the beam solar radiation, leading to a reduction in solar heat gain as well as building cooling load. On the other hand, the heating requirement of an inverted pyramidal building will be increased in winter. There is a strong dependency of building performance on the climatic condition. In this study, a generic air-conditioned office building with inclined walls set at different inclination angles was modeled using a building energy simulation program. Computer simulations were run to assess the thermal performance of the building constructed with inclined walls under different climatic conditions in three modern cities in China–Hong Kong, Shanghai and Beijing. The results reveal that for the building cases with inclined walls set at different inclination angles in subtropical Hong Kong, the saving in annual cooling load ranges from 0.6% to 10.9% and can outweigh the increase in heating load. Moreover, an inclination angle of 30° was found as a better design option for an inverted pyramidal building with symmetrical layout design under the climatic condition in Hong Kong. For the other two cities: Shanghai and Beijing, the saving in cooling load due to self-shading effect cannot offset the increased heating requirement. Design and construction of an inverted pyramidal building is not encouraged in these two

  18. Modelica Library for Building Heating, Ventilation and Air-Conditioning Systems

    Energy Technology Data Exchange (ETDEWEB)

    Wetter, Michael

    2009-06-17

    This paper presents a freely available Modelica library for building heating, ventilation and air conditioning systems. The library is based on the Modelica.Fluid library. It has been developed to support research and development of integrated building energy and control systems. The primary applications are controls design, energy analysis and model-based operation. The library contains dynamic and steady-state component models that are applicable for analyzing fast transients when designing control algorithms and for conducting annual simulations when assessing energy performance. For most models, dimensional analysis is used to compute the performance for operating points that differ from nominal conditions. This allows parameterizing models in the absence of detailed geometrical information which is often impractical to obtain during the conceptual design phase of building systems. In the first part of this paper, the library architecture and the main classes are described. In the second part, an example is presented in which we implemented a model of a hydronic heating system with thermostatic radiator valves and thermal energy storage.

  19. Energy Performance and Optimal Control of Air-conditioned Buildings Integrated with Phase Change Materials

    Science.gov (United States)

    Zhu, Na

    This thesis presents an overview of the previous research work on dynamic characteristics and energy performance of buildings due to the integration of PCMs. The research work on dynamic characteristics and energy performance of buildings using PCMs both with and without air-conditioning is reviewed. Since the particular interest in using PCMs for free cooling and peak load shifting, specific research efforts on both subjects are reviewed separately. A simplified physical dynamic model of building structures integrated with SSPCM (shaped-stabilized phase change material) is developed and validated in this study. The simplified physical model represents the wall by 3 resistances and 2 capacitances and the PCM layer by 4 resistances and 2 capacitances respectively while the key issue is the parameter identification of the model. This thesis also presents the studies on the thermodynamic characteristics of buildings enhanced by PCM and on the investigation of the impacts of PCM on the building cooling load and peak cooling demand at different climates and seasons as well as the optimal operation and control strategies to reduce the energy consumption and energy cost by reducing the air-conditioning energy consumption and peak load. An office building floor with typical variable air volume (VAV) air-conditioning system is used and simulated as the reference building in the comparison study. The envelopes of the studied building are further enhanced by integrating the PCM layers. The building system is tested in two selected cities of typical climates in China including Hong Kong and Beijing. The cold charge and discharge processes, the operation and control strategies of night ventilation and the air temperature set-point reset strategy for minimizing the energy consumption and electricity cost are studied. This thesis presents the simulation test platform, the test results on the cold storage and discharge processes, the air-conditioning energy consumption and demand

  20. Lesions of the amygdala central nucleus abolish lipoprivic-enhanced responding during oil-predicting conditioned stimuli.

    Science.gov (United States)

    Benoit, S C; Morell, J R; Davidson, T L

    1999-12-01

    T. L. Davidson, A. M. Altizer, S. C. Benoit, E. K. Walls, and T. L. Powley (1997) reported that rats show facilitated responding to conditioned stimuli (CSs) that predict oil, after administration of the lipoprivic agent, Na-2-mercaptoacetate (MA). This facilitation was blocked by vagal deafferentation. The present article extends that investigation to another structure, the amygdala central nucleus (CN). The CN receives inputs from dorsal vagal nuclei, and neurotoxic lesions of this nucleus are reported to abolish feeding in response to lipoprivic challenges. In Experiment 1, rats with ibotenic acid (IBO) lesions of the CN failed to show enhanced appetitive responding during oil-predicting CSs after administration of MA. Experiment 2 used a conditioned taste-aversion procedure to establish that rats with IBO lesions of the CN were able to discriminate the tastes of sucrose and peanut oil and had intact CS-US representations. It is concluded that the amygdala CN is a necessary structure for the detection of lipoprivic challenges.

  1. Analysis of flammability in the attached buildings to containment under severe accident conditions

    Energy Technology Data Exchange (ETDEWEB)

    Rosa, J.C. de la, E-mail: juan-carlos.de-la-rosa-blul@ec.europa.eu [European Commission Joint Research Centre (Netherlands); Fornós, Joan, E-mail: jfornosh@anacnv.com [Asociación Nuclear Ascó-Vandellós (Spain)

    2016-11-15

    Highlights: • Analysis of flammability conditions in buildings outside containment. • Stepwise approach easily applicable for any kind of containment and attached buildings layout. • Detailed application for real plant conditions has been included. - Abstract: Right after the events unfolded in Fukushima Daiichi, the European Union countries agreed in subjecting Nuclear Power Plants to Stress Tests as developed by WENRA and ENSREG organizations. One of the results as implemented in many European countries derived from such tests consisted of mandatory technical instructions issued by nuclear regulatory bodies on the analysis of potential risk of flammable gases in attached buildings to containment. The current study addresses the key aspects of the analysis of flammable gases leaking to auxiliary buildings attached to Westinghouse large-dry PWR containment for the specific situation where mitigating systems to prevent flammable gases to grow up inside containment are available, and containment integrity is preserved – hence avoiding isolation system failure. It also provides a full practical exercise where lessons learned derived from the current study – hence limited to the imposed boundary conditions – are applied. The leakage of gas from the containment to the support buildings is based on separate calculations using the EPRI-owned Modular Accident Analysis Program, MAAP4.07. The FATE™ code (facility Flow, Aerosol, Thermal, and Explosion) was used to model the transport and distribution of leaked flammable gas (H{sub 2} and CO) in the penetration buildings. FATE models the significant mixing (dilution) which occurs as the released buoyant gas rises and entrains air. Also, FATE accounts for the condensation of steam on room surfaces, an effect which acts to concentrate flammable gas. The results of the analysis show that during a severe accident, flammable conditions are unlikely to occur in compartmentalized buildings such as the one used in the

  2. Analysis of flammability in the attached buildings to containment under severe accident conditions

    International Nuclear Information System (INIS)

    Rosa, J.C. de la; Fornós, Joan

    2016-01-01

    Highlights: • Analysis of flammability conditions in buildings outside containment. • Stepwise approach easily applicable for any kind of containment and attached buildings layout. • Detailed application for real plant conditions has been included. - Abstract: Right after the events unfolded in Fukushima Daiichi, the European Union countries agreed in subjecting Nuclear Power Plants to Stress Tests as developed by WENRA and ENSREG organizations. One of the results as implemented in many European countries derived from such tests consisted of mandatory technical instructions issued by nuclear regulatory bodies on the analysis of potential risk of flammable gases in attached buildings to containment. The current study addresses the key aspects of the analysis of flammable gases leaking to auxiliary buildings attached to Westinghouse large-dry PWR containment for the specific situation where mitigating systems to prevent flammable gases to grow up inside containment are available, and containment integrity is preserved – hence avoiding isolation system failure. It also provides a full practical exercise where lessons learned derived from the current study – hence limited to the imposed boundary conditions – are applied. The leakage of gas from the containment to the support buildings is based on separate calculations using the EPRI-owned Modular Accident Analysis Program, MAAP4.07. The FATE™ code (facility Flow, Aerosol, Thermal, and Explosion) was used to model the transport and distribution of leaked flammable gas (H_2 and CO) in the penetration buildings. FATE models the significant mixing (dilution) which occurs as the released buoyant gas rises and entrains air. Also, FATE accounts for the condensation of steam on room surfaces, an effect which acts to concentrate flammable gas. The results of the analysis show that during a severe accident, flammable conditions are unlikely to occur in compartmentalized buildings such as the one used in the

  3. Multi-level nonlinear modeling verification scheme of RC high-rise wall buildings

    OpenAIRE

    Alwaeli, W.; Mwafy, A.; Pilakoutas, K.; Guadagnini, M.

    2017-01-01

    Earthquake-resistant reinforced concrete (RC) high-rise wall buildings are designed and detailed to respond well beyond the elastic range under the expected earthquake ground motions. However, despite their considerable section depth, in terms of analysis, RC walls are still often treated as linear elements, ignoring the effect of deformation compatibility. Due to the limited number of available comprehensive experimental studies on RC structural wall systems subjected to cycling loading, few...

  4. Evaluation of Heating, Ventilation, and Air conditioning (HVAC System Performance in an Administrative Building in Tehran (Iran

    Directory of Open Access Journals (Sweden)

    H. Mari Oriyad

    2014-09-01

    Full Text Available Introduction: One of the factors influencing on indoor air quality of the buildings is performance of HVAC (heating, ventilation, and air conditioning systems. These systems supply clean and odorless air, with temperature, humidity, and air velocity within comfort ranges for the residents. The aim of this study was to evaluate performance HVAC system in an administrative building in Tehran. .Material and Method: A questionnaire, developed in their research was used to assess the building occupants’ perception about the performance of HVAC system. To evaluate the performance of HVAC systems, air velocities were measured in the diffusers using a thermal anemometer. Moreover, CO2 concentration, air temperature and relative humidity were measured in the whole floors of the building. Air distribution inside the building was evaluated using smoke test. .Results: Most of the studied people complained about the direction of airflow, thermal conditions and cigarette odor. The highest level of carbon dioxide was measured at 930 ppm inside the restaurant. The maximum and minimum air temperatures and relative humidity were measured 28.3-13.8° C and 28.4-23% respectively. Smoke test showed that the air distribution/direction wasn’t suitable in one third of air diffusers. .Conclusion: Improper air distribution / direction was the main problem with the studied HVAC system which could be corrected by adjusting and balancing of the system.

  5. Intraspecific variation in physiological condition of reef-building corals associated with differential levels of chronic disturbance.

    Science.gov (United States)

    Pisapia, Chiara; Anderson, Kristen; Pratchett, Morgan S

    2014-01-01

    Even in the absence of major disturbances (e.g., cyclones, bleaching), corals are subject to high levels of partial or whole-colony mortality, often caused by chronic and small-scale disturbances. Depending on levels of background mortality, these chronic disturbances may undermine individual fitness and have significant consequences on the ability of colonies to withstand subsequent acute disturbances or environmental change. This study quantified intraspecific variations in physiological condition (measured based on total lipid content and zooxanthellae density) through time in adult colonies of two common and widespread coral species (Acropora spathulata and Pocillopora damicornis), subject to different levels of biological and physical disturbances along the most disturbed reef habitat, the crest. Marked intraspecific variation in the physiological condition of A. spathulata was clearly linked to differences in local disturbance regimes and habitat. Specifically, zooxanthellae density decreased (r2 = 26, df = 5,42, pzooxanthellae density was strongly and negatively correlated with the individual level of partial mortality (r2 = 26, df = 5,42, pclimate-induced coral bleaching.

  6. Comparison of MicroRNAs Mediated in Reactivation of the γ-Globin in β-Thalassemia Patients, Responders and Non-Responders to Hydroxyurea.

    Science.gov (United States)

    Hojjati, Mohammad T; Azarkeivan, Azita; Pourfathollah, Ali A; Amirizadeh, Naser

    2017-03-01

    Drug induction of Hb F seems to be an ideal therapy for patients with hemoglobin (Hb) disorders, and many efforts have been made to reveal the mechanism behind it. Thus, we examined in vivo expression of some microRNAs (miRNAs) that are thought to be involved in this process. Among β-thalassemia (β-thal) patients who were undergoing hydroxyurea (HU) therapy in the past 3 months and five healthy individuals, five responders and five non-responders, were also included in the study. Erythroid progenitors were isolated by magnetic activated cell sorting (MACS) and miRNA expression analyzed using reverse transcription-polymerase chain reaction (RT-PCR). We showed that γ-globin, miR-210 and miR-486-3p had higher levels in the responders than the non-responders group. Moreover, miR-150 and miR-320 had higher levels in the healthy group than both non-responders and responders groups, but the expression of miR-96 did not show any significant difference between the study groups. To the best of our knowledge, this is the first study proposing that 'induction of cellular hypoxic condition by Hb F inducing agents' could be the milestone of possible mechanisms that explain why responders are able to reactivate γ-globin genes and subsequently, more production of Hb F, in response to these agents in comparison to non-responders. However, further investigations need to be performed to verify this hypothesis.

  7. Fuzzy logic control of air-conditioning system in residential buildings

    Directory of Open Access Journals (Sweden)

    Abdel-Hamid Attia

    2015-09-01

    Full Text Available There has been a rising concern in reducing the energy consumption in building. Heating ventilation and air condition system is the biggest consumer of energy in building. In this study, fuzzy logic control of the air conditioning system of building for efficient energy operation and comfortable environment is investigated. A theoretical model of the fan coil unit (FCU and the heat transfer between air and coolant fluid is derived. The controlled variables are the room temperature and relative humidity and control consequents are the percentage of chilled and hot water flow rates at summer and the percentage of hot water and steam injected flow rates at winter. A computer simulation has been conducted and fuzzy control results are compared with that of conventional Proportional-Integral-Derivative control. It was found that the proposed control strategy satisfies the space load and at the same time to achieve the comfort zone, as defined by the ASHRAE code. Meanwhile PID control fails to adjust the room temperature at part-load operations. It has been demonstrated that fuzzy controller operation is more efficient and consumes less energy than PID control.

  8. On the design of high-rise buildings with a specified level of reliability

    Science.gov (United States)

    Dolganov, Andrey; Kagan, Pavel

    2018-03-01

    High-rise buildings have a specificity, which significantly distinguishes them from traditional buildings of high-rise and multi-storey buildings. Steel structures in high-rise buildings are advisable to be used in earthquake-proof regions, since steel, due to its plasticity, provides damping of the kinetic energy of seismic impacts. These aspects should be taken into account when choosing a structural scheme of a high-rise building and designing load-bearing structures. Currently, modern regulatory documents do not quantify the reliability of structures. Although the problem of assigning an optimal level of reliability has existed for a long time. The article shows the possibility of designing metal structures of high-rise buildings with specified reliability. Currently, modern regulatory documents do not quantify the reliability of high-rise buildings. Although the problem of assigning an optimal level of reliability has existed for a long time. It is proposed to establish the value of reliability 0.99865 (3σ) for constructions of buildings and structures of a normal level of responsibility in calculations for the first group of limiting states. For increased (construction of high-rise buildings) and reduced levels of responsibility for the provision of load-bearing capacity, it is proposed to assign respectively 0.99997 (4σ) and 0.97725 (2σ). The coefficients of the use of the cross section of a metal beam for different levels of security are given.

  9. Preventing Dampness Related Health Risks at the Design Stage of Buildings in Mediterranean Climates: A Cyprus Case Study

    Directory of Open Access Journals (Sweden)

    Ugochukwu Kenechi Elinwa

    2018-05-01

    Full Text Available Dampness is a major building challenge that poses a health risk by aiding the growth of mold and other related microorganisms in very humid areas. Thus, the correction of these post-effects results in high maintenance costs via energy consumption, due to the prolonged heating of damp rooms and post-treatment, especially during the winter. A survey of 2000 valid respondents living in apartment-style buildings was conducted and analyzed using SPSS software. In this study, the AutoDesk Computational Fluid Dynamics (ACFD software was used to perform a simulation for building materials analysis, to evaluate them for suitability in high humidity areas and to select the best building orientation for adequate and natural ventilation. The analysis aimed to observe the indoor air conditions due to environmental air flow conditions. The relationships of the airflow conditions to the material properties were measured. The methodology involves a Failure Modes and Effects Analysis to determine the level and nature of the dampness sources. The Design-Expert Statistical-Software 10 confirmed the simulation results. The simulation revealed a lower percentage of relative humidity and temperature in Adobe walls than in brick walls.

  10. Estimating Solar Energy Potential in Buildings on a Global Level

    DEFF Research Database (Denmark)

    Petrichenko, Ksenia

    2015-01-01

    This chapter contributes to the debate around net-zero energy concept from a global perspective. By means of comprehensive modelling, it analyses how much global building energy consumption could be reduced through utilisation of building-integrated solar energy technologies and energy......-efficiency improvements. Valuable insights on the locations and building types, in which it is feasible to achieve a net-zero level of energy performance through solar energy utilisation, are presented in world maps....

  11. Unintended anchors: Building rating systems and energy performance goals for U.S. buildings

    International Nuclear Information System (INIS)

    Klotz, Leidy; Mack, Daniel; Klapthor, Brent; Tunstall, Casey; Harrison, Jennilee

    2010-01-01

    In the U.S., where buildings account for 40% of energy use, commercial buildings use more energy per unit area than ever before. However, exemplary buildings demonstrate the feasibility of much better energy performance at no additional first cost. This research examines one possible explanation for this inconsistency. The aim is to investigate whether the anchoring bias, which refers to our tendency to gravitate towards a pre-defined standard regardless of its relevance, influences energy performance goals in building design. The scope examines professionals who help set energy performance goals for U.S. buildings. Prior to being asked to set an energy performance goal, these professionals were randomly directed to one of three series of questions. One series set an anchor of 90% energy reduction beyond standard practice, one set a 30% anchor, and one set no anchor. Respondents exposed to the 90% anchor, and respondents exposed to no anchor at all, set higher energy performance goals than respondents exposed to the 30% anchor. These results suggest that building rating systems that only reward incremental energy improvements may inadvertently create anchors, thereby discouraging more advanced energy performance goals and inhibiting energy performance that is technically and economically feasible.

  12. Building a competent health manager at district level: a grounded theory study from Eastern Uganda.

    Science.gov (United States)

    Tetui, Moses; Hurtig, Anna-Karin; Ekirpa-Kiracho, Elizabeth; Kiwanuka, Suzanne N; Coe, Anna-Britt

    2016-11-21

    Health systems in low-income countries are often characterized by poor health outcomes. While many reasons have been advanced to explain the persistently poor outcomes, management of the system has been found to play a key role. According to a WHO framework, the management of health systems is central to its ability to deliver needed health services. In this study, we examined how district managers in a rural setting in Uganda perceived existing approaches to strengthening management so as to provide a pragmatic and synergistic model for improving management capacity building. Twenty-two interviews were conducted with district level administrative and political managers, district level health managers and health facility managers to understand their perceptions and definitions of management and capacity building. Kathy Charmaz's constructive approach to grounded theory informed the data analysis process. An interative, dynamic and complex model with three sub-process of building a competent health manager was developed. A competent manager was understood as one who knew his/her roles, was well informed and was empowered to execute management functions. Professionalizing health managers which was viewed as the foundation, the use of engaging learning approaches as the inside contents and having a supportive work environment the frame of the model were the sub-processes involved in the model. The sub-processes were interconnected although the respondents agreed that having a supportive work environment was more time and effort intensive relative to the other two sub-processes. The model developed in our study makes four central contributions to enhance the WHO framework and the existing literature. First, it emphasizes management capacity building as an iterative, dynamic and complex process rather than a set of characteristics of competent managers. Second, our model suggests the need for professionalization of health managers at different levels of the health

  13. Modeling and optimization of energy generation and storage systems for thermal conditioning of buildings targeting conceptual building design

    Energy Technology Data Exchange (ETDEWEB)

    Grahovac, Milica

    2012-11-29

    The thermal conditioning systems are responsible for almost half of the energy consump-tion by commercial buildings. In many European countries and in the USA, buildings account for around 40% of primary energy consumption and it is therefore vital to explore further ways to reduce the HVAC (Heating, Ventilation and Air Conditioning) system energy consumption. This thesis investigates the relationship between the energy genera-tion and storage systems for thermal conditioning of buildings (shorter: primary HVAC systems) and the conceptual building design. Certain building design decisions irreversibly influence a building's energy performance and, conversely, many generation and storage components impose restrictions on building design and, by their nature, cannot be introduced at a later design stage. The objective is, firstly, to develop a method to quantify this influence, in terms of primary HVAC system dimensions, its cost, emissions and energy consumption and, secondly, to enable the use of the developed method by architects during the conceptual design. In order to account for the non-stationary effects of the intermittent renewable energy sources (RES), thermal storage and for the component part load efficiencies, a time domain system simulation is required. An abstract system simulation method is proposed based on seven pre-configured primary HVAC system models, including components such as boil-ers, chillers and cooling towers, thermal storage, solar thermal collectors, and photovoltaic modules. A control strategy is developed for each of the models and their annual quasi-stationary simulation is performed. The performance profiles obtained are then used to calculate the energy consumption, carbon emissions and costs. The annuity method has been employed to calculate the cost. Optimization is used to automatically size the HVAC systems, based on their simulation performance. Its purpose is to identify the system component dimensions that provide

  14. Modeling and optimization of energy generation and storage systems for thermal conditioning of buildings targeting conceptual building design

    Energy Technology Data Exchange (ETDEWEB)

    Grahovac, Milica

    2012-11-29

    The thermal conditioning systems are responsible for almost half of the energy consump-tion by commercial buildings. In many European countries and in the USA, buildings account for around 40% of primary energy consumption and it is therefore vital to explore further ways to reduce the HVAC (Heating, Ventilation and Air Conditioning) system energy consumption. This thesis investigates the relationship between the energy genera-tion and storage systems for thermal conditioning of buildings (shorter: primary HVAC systems) and the conceptual building design. Certain building design decisions irreversibly influence a building's energy performance and, conversely, many generation and storage components impose restrictions on building design and, by their nature, cannot be introduced at a later design stage. The objective is, firstly, to develop a method to quantify this influence, in terms of primary HVAC system dimensions, its cost, emissions and energy consumption and, secondly, to enable the use of the developed method by architects during the conceptual design. In order to account for the non-stationary effects of the intermittent renewable energy sources (RES), thermal storage and for the component part load efficiencies, a time domain system simulation is required. An abstract system simulation method is proposed based on seven pre-configured primary HVAC system models, including components such as boil-ers, chillers and cooling towers, thermal storage, solar thermal collectors, and photovoltaic modules. A control strategy is developed for each of the models and their annual quasi-stationary simulation is performed. The performance profiles obtained are then used to calculate the energy consumption, carbon emissions and costs. The annuity method has been employed to calculate the cost. Optimization is used to automatically size the HVAC systems, based on their simulation performance. Its purpose is to identify the system component dimensions that provide minimal

  15. Analyzing energy consumption while heating one-layer building envelopes in conditions of intermittent heating

    Directory of Open Access Journals (Sweden)

    Vytchikov Yury

    2017-01-01

    Full Text Available This paper focuses on energy consumption for heating single layer building envelopes, used in conditions of intermittent heating in different physical and mechanical and thermophysical parameters of construction materials. The authors investigated several variants of single-layer building envelopes, used frequently in building practice, with different density and coefficients of building materials thermal conductivity. For each variant of a building envelope heat leakage and time spent on heating were calculated. Heating time was calculated by both exact and approximate analytical method. Then the researchers draw a graphic dependence of energy consumption on the density of the material taking this computational data as a basis. Further analysis showed that building envelopes made of lightweight aggregate concrete and porous concrete were the most energy efficient.This paper focuses on energy consumption for heating single layer building envelopes, used in conditions of intermittent heating in different physical and mechanical and thermophysical parameters of construction materials. The authors investigated several variants of single-layer building envelopes, used frequently in building practice, with different density and coefficients of building materials thermal conductivity. For each variant of a building envelope heat leakage and time spent on heating were calculated. Heating time was calculated by both exact and approximate analytical method. Then the researchers draw a graphic dependence of energy consumption on the density of the material taking this computational data as a basis. Further analysis showed that building envelopes made of lightweight aggregate concrete and porous concrete were the most energy efficient.

  16. Upgrade Opportunities for Buildings in City Centres

    Directory of Open Access Journals (Sweden)

    Silva M.

    2012-10-01

    Full Text Available This proposal focus on the potential of the existing buildings upgrade process in achieving the 20-20-20 goals, as these are the biggest energy consumers, the most significant built area and the better placed buildings within our cities. These buildings frequently lack basic maintenance and need intervention, but include within themselves a vast amount of incorporated energy and centuries of construction knowledge. Beyond the advantages that may result from re-attracting people back into the city centre, upgrading these existing buildings can also have positive bounce-back effect on the reduction of the energy needs related to transportation, as demonstrated in studies that alert to the impact of the building sprawl in the total energy use. As “buildings account for 40 % of total energy consumption in the Union”, the better performance of this sector has a significant role, remembering that “these requirements shall take account of general indoor climate conditions, in order to avoid possible negative effects such as inadequate ventilation, as well as local conditions and the designated function and the age of the building” [1]. The importance of “upgrading” the existing buildings resides on the fact that new buildings represent only approximately 1 or 2% of the total usable area, an estimate that is bound to decrease due to the current construction crisis. While the recent buildings tend to be more efficient, the numerous existing buildings are important stakeholders due to their massive consumptions and incorporated energy. The ongoing Annex 56 on “Energy & Greenhouse Gas Optimized Building Renovation” assumes that “Current standards do not respond effectively to the numerous constraints imposed by existing buildings and in many cases, the requirements result in very expensive measures and complex procedures, seldom accepted by occupants, owners or developers. It is then urgent for the new standards to respond to these

  17. Waste conditioning components for a new radwaste building

    International Nuclear Information System (INIS)

    Lewitz, J.C.; Stoelken, G.

    2001-01-01

    In the year 1999 Hansa Projekt Anlagentechnik GmbH made a basic study for the equipment of a new to be build radwaste building for TPC, Taiwan. Within an offer there was made an overall concept together with a proposal for system integration including supply, erection and put into operation for the following components supercompactor with in-/output device, overpack-filling station, resindrying- and filling unit, sorting tables for solid radwaste, cementation unit for liquid radwaste, cementation unit for grouting, drum inspection and decontamination station, storages for primary and conditioned radwaste, HVAC with filtration for several components and a roller conveyor system for transfer throughout the radwaste building. This overall concept was to be realized very similar by the client. The HPA scope of supply was focused onto the key components supercompactor with in-/output device, roller conveyor and turntable for cartridges and pellets, overpack-filling station, sorting tables, HVAC with filtration for supercompactor and sorting tables, and last but not least a drum inspection and decontamination system. In the following at first the functioning of HPA-components and the system as whole will be declared. At second components and system will be shown in detail together with figures and technical data. (orig.)

  18. User evaluations of energy efficient buildings: the interplay of buildings and users in seven European case studies

    Energy Technology Data Exchange (ETDEWEB)

    Thomsen, Judith; Hauge, Aashild Lappegaard; Denizou, Karine; Jerkoe, Sidsel; Waagoe, Solvaar; Berker, Thomas

    2011-07-01

    The buildings in our study have been operational for just a short period and most of them are still in an adjustment phase. The findings show that users in all case studies often stressed the positive aspects connected to the newness and the architectural quality of the buildings. The interviews also show that energy efficiency is often regarded as a bonus or side effect that is gladly accepted but not the main criteria for choosing a house. Nonetheless, most residents seemed to appreciate the environmental benefits over time. Several respondents were also more concerned about the environment now than before they moved into or started to work in an energy efficient building, and they also reported more environmentally friendly behaviour. In most of the case studies, concerns were expressed about thermal comfort. Informants often experienced the building as too hot in the summer and/or too cold in the winter. This perceived discomfort caused different types of personal actions, which had a potential to interfere with the concept and the calculated energy balance. In order to improve internal conditions, the users in almost every case intervened with the planned use. They found common and known ways to improving their comfort in the buildings without considering how to optimize the new system. None of the respondents had much prior knowledge of energy efficient buildings before moving in or starting to work in the case study buildings. They did not know what to expect from their new environment, and were unfamiliar with the concepts. Many of the informants complained about a lack of information on systems and insufficient training. The studies also show that the occupants desired to control at least some operational aspects. Despite intermittent difficulties with thermal comfort, the tolerance for the buildings performance appeared to be high throughout all the case studies and many respondents were proud of 'their' buildings. Energy efficient buildings are not the

  19. User evaluations of energy efficient buildings: the interplay of buildings and users in seven European case studies

    Energy Technology Data Exchange (ETDEWEB)

    Thomsen, Judith; Hauge, Aashild Lappegaard; Denizou, Karine; Jerkoe, Sidsel; Waagoe, Solvaar; Berker, Thomas

    2011-07-01

    The buildings in our study have been operational for just a short period and most of them are still in an adjustment phase. The findings show that users in all case studies often stressed the positive aspects connected to the newness and the architectural quality of the buildings. The interviews also show that energy efficiency is often regarded as a bonus or side effect that is gladly accepted but not the main criteria for choosing a house. Nonetheless, most residents seemed to appreciate the environmental benefits over time. Several respondents were also more concerned about the environment now than before they moved into or started to work in an energy efficient building, and they also reported more environmentally friendly behaviour. In most of the case studies, concerns were expressed about thermal comfort. Informants often experienced the building as too hot in the summer and/or too cold in the winter. This perceived discomfort caused different types of personal actions, which had a potential to interfere with the concept and the calculated energy balance. In order to improve internal conditions, the users in almost every case intervened with the planned use. They found common and known ways to improving their comfort in the buildings without considering how to optimize the new system. None of the respondents had much prior knowledge of energy efficient buildings before moving in or starting to work in the case study buildings. They did not know what to expect from their new environment, and were unfamiliar with the concepts. Many of the informants complained about a lack of information on systems and insufficient training. The studies also show that the occupants desired to control at least some operational aspects. Despite intermittent difficulties with thermal comfort, the tolerance for the buildings performance appeared to be high throughout all the case studies and many respondents were proud of 'their' buildings. Energy efficient buildings are

  20. Infrared survey of 50 buildings constructed during 100 years: thermal performances and damage conditions

    Science.gov (United States)

    Ljungberg, Sven-Ake

    1995-03-01

    Different building constructions and craftsmanship give rise to different thermal performance and damage conditions. The building stock of most industrial countries consists of buildings of various age, and constructions, from old historic buildings with heavy stone or wooden construction, to new buildings with heavy or light concrete construction, or modern steel or wooden construction. In this paper the result from a detailed infrared survey of 50 buildings from six Swedish military camps is presented. The presentation is limited to a comparison of thermal performance and damage conditions of buildings of various ages, functions, and constructions, of a building period of more than 100 years. The result is expected to be relevant even to civilian buildings. Infrared surveys were performed during 1992-1993, with airborne, and mobile short- and longwave infrared systems, out- and indoor thermography. Interpretation and analysis of infrared data was performed with interactive image and analyzing systems. Field inspections were carried out with fiber optics system, and by ocular inspections. Air-exchange rate was measured in order to quantify air leakages through the building envelope, indicated in thermograms. The objects studied were single-family houses, barracks, office-, service-, school- and exercise buildings, military hotels and restaurants, aircraft hangars, and ship factory buildings. The main conclusions from this study are that most buildings from 1880 - 1940 have a solid construction with a high quality of craftsmanship, relatively good thermal performance, due to extremely thick walls, and adding insulation at the attic floor. From about 1940 - 1960 the quality of construction, thermal performance and craftsmanship seem to vary a lot. Buildings constructed during the period of 1960 - 1990 have in general the best thermal performance due to a better insulation capacity, however, also one finds here the greatest variety of problems. The result from this

  1. Final deactivation project report on the High Radiation Level Analytical Facility, Building 3019B at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1997-09-01

    The purpose of this report is to document the condition of the High Radiation Level Analytical Facility (Building 3019B) at Oak Ridge National Laboratory (ORNL) after completion of deactivation activities. This report identifies the activities conducted to place the facility in a safe and environmentally sound condition prior to transfer to the Environmental Restoration EM-40 Program. This document provides a history and description of the facility prior to the commencement of deactivation activities and documents the condition of the building after completion of all deactivation activities. Turnover items, such as the Post-Deactivation Surveillance and Maintenance (S ampersand M) Plan, remaining hazardous materials inventory, radiological controls, safeguards and security, quality assurance, facility operations, and supporting documentation provided in the Nuclear Material and Facility Stabilization (EM-60) Turnover package are discussed. Building 3019B will require access to perform required S ampersand M activities to maintain the building safety envelope. Building 3019B was stabilized during deactivation so that when transferred to the EM-40 Program, only a minimal S ampersand M effort would be required to maintain the building safety envelope. Other than the minimal S ampersand M activities the building will be unoccupied and the exterior doors locked to prevent unauthorized access. The building will be entered only to perform the required S ampersand M until decommissioning activities begin

  2. Final deactivation project report on the High Radiation Level Analytical Facility, Building 3019B at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-09-01

    The purpose of this report is to document the condition of the High Radiation Level Analytical Facility (Building 3019B) at Oak Ridge National Laboratory (ORNL) after completion of deactivation activities. This report identifies the activities conducted to place the facility in a safe and environmentally sound condition prior to transfer to the Environmental Restoration EM-40 Program. This document provides a history and description of the facility prior to the commencement of deactivation activities and documents the condition of the building after completion of all deactivation activities. Turnover items, such as the Post-Deactivation Surveillance and Maintenance (S&M) Plan, remaining hazardous materials inventory, radiological controls, safeguards and security, quality assurance, facility operations, and supporting documentation provided in the Nuclear Material and Facility Stabilization (EM-60) Turnover package are discussed. Building 3019B will require access to perform required S&M activities to maintain the building safety envelope. Building 3019B was stabilized during deactivation so that when transferred to the EM-40 Program, only a minimal S&M effort would be required to maintain the building safety envelope. Other than the minimal S&M activities the building will be unoccupied and the exterior doors locked to prevent unauthorized access. The building will be entered only to perform the required S&M until decommissioning activities begin.

  3. An open-source automated continuous condition-based maintenance platform for commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Katipamula, Srinivas; Gowri, Krishnan; Hernandez, George

    2016-09-09

    This paper describes one such reference process that can be deployed to provide continuous automated conditioned-based maintenance management for buildings that have BIM, a building automation system (BAS) and a computerized maintenance management software (CMMS) systems. The process can be deployed using an open source transactional network platform, VOLTTRON™, designed for distributed sensing and controls and supports both energy efficiency and grid services.

  4. Examination of the effects of varenicline, bupropion, lorcaserin, or naltrexone on responding for conditioned reinforcement in nicotine-exposed rats.

    Science.gov (United States)

    Guy, Elizabeth G; Fisher, Daniel C; Higgins, Guy A; Fletcher, Paul J

    2014-12-01

    Smoking tobacco remains one of the leading causes of preventable deaths in North America. Nicotine reinforces smoking behavior, in part, by enhancing the reinforcing properties of reward-related stimuli, or conditioned stimuli (CSs), associated with tobacco intake. To investigate how pharmaceutical interventions may affect this property of nicotine, we examined the effect of four US Food and Drug Administration (FDA) approved drugs on the ability of nicotine to enhance operant responding for a CS as a conditioned reinforcer. Thirsty rats were exposed to 13 Pavlovian sessions where a CS was paired with water delivery. Nicotine (0.4 mg/kg) injections were administered before each Pavlovian session. Then, in separate groups of rats, the effects of varenicline (1 mg/kg), bupropion (10 and 30 mg/kg), lorcaserin (0.6 mg/kg), and naltrexone (2 mg/kg), and their interaction with nicotine on responding for conditioned reinforcement were examined. Varenicline and lorcaserin each reduced nicotine-enhanced responding for conditioned reinforcement, whereas naltrexone had a modest effect of reducing response enhancements by nicotine. In contrast, bupropion enhanced the effect of nicotine on this measure. The results of these studies may inform how pharmaceutical interventions can affect smoking cessation attempts and relapse through diverse mechanisms, either substituting for, or interacting with, the reinforcement-enhancing properties of nicotine.

  5. Thermal comfort in air-conditioned buildings in hot and humid climates--why are we not getting it right?

    Science.gov (United States)

    Sekhar, S C

    2016-02-01

    While there are plenty of anecdotal experiences of overcooled buildings in summer, evidence from field studies suggests that there is indeed an issue of overcooling in tropical buildings. The findings suggest that overcooled buildings are not a consequence of occupant preference but more like an outcome of the HVAC system design and operation. Occupants' adaptation in overcooled indoor environments through additional clothing cannot be regarded as an effective mitigating strategy for cold thermal discomfort. In the last two decades or so, several field studies and field environmental chamber studies in the tropics provided evidence for occupants' preference for a warmer temperature with adaptation methods such as elevated air speeds. It is important to bear in mind that indoor humidity levels are not compromised as they could have an impact on the inhaled air condition that could eventually affect perceived air quality. This review article has attempted to track significant developments in our understanding of the thermal comfort issues in air-conditioned office and educational buildings in hot and humid climates in the last 25 years, primarily on occupant preference for thermal comfort in such climates. The issue of overcooled buildings, by design intent or otherwise, is discussed in some detail. Finally, the article has explored some viable adaptive thermal comfort options that show considerable promise for not only improving thermal comfort in tropical buildings but are also energy efficient and could be seen as sustainable solutions. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Raetrad model extensions for radon entry into multi-level buildings with basements or crawl spaces.

    Science.gov (United States)

    Nielson, K K; Rogers, V C; Rogers, V; Holt, R B

    1997-10-01

    The RAETRAD model was generalized to characterize radon generation and movement from soils and building materials into multi-level buildings with basements or crawl spaces. With the generalization, the model retains its original simplicity and ease of use. The model calculates radon entry rates that are consistent with measurements published for basement test structures at Colorado State University, confirming approximately equal contributions from diffusion and pressure-driven air flow at indoor-outdoor air pressure differences of deltaP(i-o) = -3.5 Pa. About one-fourth of the diffusive radon entry comes from concrete slabs and three-fourths comes from the surrounding soils. Calculated radon entry rates with and without a barrier over floor-wall shrinkage cracks generally agree with Colorado State University measurements when a sustained pressure of deltaP(i-o) = -2 Pa is used to represent calm wind (<1 m s(-1)) conditions. Calculated radon distributions in a 2-level house also are consistent with published measurements and equations.

  7. Owners perception on the adoption of building envelope energy efficiency measures in Swedish detached houses

    Energy Technology Data Exchange (ETDEWEB)

    Nair, Gireesh [Ecotechnology, Mid Sweden University, SE-83125 Ostersund (Sweden); Gustavsson, Leif [Ecotechnology, Mid Sweden University, SE-83125 Ostersund (Sweden); Mahapatra, Krushna [Ecotechnology, Mid Sweden University, SE-83125 Ostersund (Sweden)

    2010-07-15

    The paper focuses on Swedish homeowners' need for and perceptions about adopting building envelop energy efficiency measures. The paper is based on a questionnaire survey of 3059 homeowners (response rate of 36%) selected by stratified random sampling during the summer of 2008. The results showed that 70-90% of the respondents had no intention of adopting such a measure over the next 10 years. The main reasons for non-adoption were that homeowners were satisfied with the physical condition, thermal performance, and aesthetics of their existing building envelope components. A greater proportion of respondents perceived that improved attic insulation has more advantages than energy efficient windows and improved wall insulation, but windows were more likely to be installed than improved attic insulation. Respondents gave high priority to economic factors in deciding on an energy efficiency measure. Interpersonal sources, construction companies, installers, and energy advisers were important sources of information for homeowners as they planned to adopt building envelope energy efficiency measures. Policy measures to facilitate the rate of adoption of energy efficient building envelope measures are discussed.

  8. Owners perception on the adoption of building envelope energy efficiency measures in Swedish detached houses

    International Nuclear Information System (INIS)

    Nair, Gireesh; Gustavsson, Leif; Mahapatra, Krushna

    2010-01-01

    The paper focuses on Swedish homeowners' need for and perceptions about adopting building envelop energy efficiency measures. The paper is based on a questionnaire survey of 3059 homeowners (response rate of 36%) selected by stratified random sampling during the summer of 2008. The results showed that 70-90% of the respondents had no intention of adopting such a measure over the next 10 years. The main reasons for non-adoption were that homeowners were satisfied with the physical condition, thermal performance, and aesthetics of their existing building envelope components. A greater proportion of respondents perceived that improved attic insulation has more advantages than energy efficient windows and improved wall insulation, but windows were more likely to be installed than improved attic insulation. Respondents gave high priority to economic factors in deciding on an energy efficiency measure. Interpersonal sources, construction companies, installers, and energy advisers were important sources of information for homeowners as they planned to adopt building envelope energy efficiency measures. Policy measures to facilitate the rate of adoption of energy efficient building envelope measures are discussed.

  9. Owners perception on the adoption of building envelope energy efficiency measures in Swedish detached houses

    Energy Technology Data Exchange (ETDEWEB)

    Nair, Gireesh; Gustavsson, Leif; Mahapatra, Krushna [Ecotechnology, Mid Sweden University, SE-83125 Oestersund (Sweden)

    2010-07-15

    The paper focuses on Swedish homeowners' need for and perceptions about adopting building envelop energy efficiency measures. The paper is based on a questionnaire survey of 3059 homeowners (response rate of 36%) selected by stratified random sampling during the summer of 2008. The results showed that 70-90% of the respondents had no intention of adopting such a measure over the next 10 years. The main reasons for non-adoption were that homeowners were satisfied with the physical condition, thermal performance, and aesthetics of their existing building envelope components. A greater proportion of respondents perceived that improved attic insulation has more advantages than energy efficient windows and improved wall insulation, but windows were more likely to be installed than improved attic insulation. Respondents gave high priority to economic factors in deciding on an energy efficiency measure. Interpersonal sources, construction companies, installers, and energy advisers were important sources of information for homeowners as they planned to adopt building envelope energy efficiency measures. Policy measures to facilitate the rate of adoption of energy efficient building envelope measures are discussed. (author)

  10. Contextual Change After Fear Acquisition Affects Conditioned Responding and the Time Course of Extinction Learning-Implications for Renewal Research.

    Science.gov (United States)

    Sjouwerman, Rachel; Niehaus, Johanna; Lonsdorf, Tina B

    2015-01-01

    Context plays a central role in retrieving (fear) memories. Accordingly, context manipulations are inherent to most return of fear (ROF) paradigms (in particular renewal), involving contextual changes after fear extinction. Context changes are, however, also often embedded during earlier stages of ROF experiments such as context changes between fear acquisition and extinction (e.g., in ABC and ABA renewal). Previous studies using these paradigms have however focused exclusively on the context switch after extinction (i.e., renewal). Thus, the possibility of a general effect of context switch on conditioned responding that may not be conditional to preceding extinction learning remains unstudied. Hence, the current study investigated the impact of a context switch between fear acquisition and extinction on immediate conditioned responding and on the time-course of extinction learning by using a multimodal approach. A group that underwent contextual change after fear conditioning (AB; n = 36) was compared with a group without a contextual change from acquisition to extinction (AA; n = 149), while measuring physiological (skin conductance and fear potentiated startle) measures and subjective fear ratings. Contextual change between fear acquisition and extinction had a pronounced effect on both immediate conditioned responding and on the time course of extinction learning in skin conductance responses and subjective fear ratings. This may have important implications for the mechanisms underlying and the interpretation of the renewal effect (i.e., contextual switch after extinction). Consequently, future studies should incorporate designs and statistical tests that disentangle general effects of contextual change from genuine ROF effects.

  11. Thermal comfort characteristics of some selected building materials in the regional setting of Ile-Ife, Nigeria

    Directory of Open Access Journals (Sweden)

    S. K. Fasogbon

    2015-07-01

    Full Text Available In Ile-Ife, it is very common to see quite a lot of local people engaging in mud bricks moulding, concrete block making, mud house construction and the bricklaying profession in general. These have particular bearing on the economy and the political situation of the people involved as in the profession there is set of rules and regulations guiding the rate and procedure for carrying out any such moulding or construction work. Considering the importance of this, the present study investigated the thermal performance of some selected building materials in the ancient city of Ile-Ife in Nigeria. The work demonstrated how a building envelope responds to outdoor conditions through graphic illustrations. This was followed by constructing three physical building models, with model 1 constructed of mud bricks, model 2 constructed of concrete blocks and model 3 constructed of cast concrete. Each of the models was first roofed with galvanised Iron roofing sheets, later with aluminium roofing sheets and finally with asbestos roofing. Readings were taken by inserting TGP-4500 Data loggers into appropriate positions. The results showed that internal temperatures in the mud-brick and cast concrete buildings remained fairly stable despite external diurnal fluctuations. Humidity data collected also showed that fluctuations in external humidity levels do not affect humidity levels within the mud-brick and cast concrete structures significantly. On the other hand, the structure made of concrete blocks responded more to external fluctuations in temperature and humidity. Moreover, humidity levels in the cast concrete building were the least, followed by those in the mud-brick house; while the concrete block structure had the highest level of humidity. It was also discovered that aluminium roofing gave the highest internal temperature, followed by galvanised iron roofing and the least was seen with asbestos roofing. For external diurnal fluctuations, building model

  12. Emotional eating and Pavlovian learning: evidence for conditioned appetitive responding to negative emotional states.

    Science.gov (United States)

    Bongers, Peggy; Jansen, Anita

    2017-02-01

    Appetitive learning has been demonstrated several times using neutral cues or contexts as a predictor of food intake and it has been shown that humans easily learn cued desires for foods. It has, however, never been studied whether internal cues are also capable of appetitive conditioning. In this study, we tested whether humans can learn cued eating desires to negative moods as conditioned stimuli (CS), thereby offering a potential explanation of emotional eating (EE). Female participants were randomly presented with 10 different stimuli eliciting either negative or neutral emotional states, with one of these states paired with eating chocolate. Expectancy to eat, desire to eat, salivation, and unpleasantness of experiencing negative emotions were assessed. After conditioning, participants were brought into a negative emotional state and were asked to choose between money and chocolate. Data showed differential conditioned responding on the expectancy and desire measures, but not on salivation. Specific conditioned effects were obtained for participants with a higher BMI (body mass index) on the choice task, and for participants high on EE on the unpleasantness ratings. These findings provide the first experimental evidence for the idea that negative emotions can act as conditioned stimuli, and might suggest that classical conditioning is involved in EE.

  13. Information support of monitoring of technical condition of buildings in construction risk area

    Science.gov (United States)

    Skachkova, M. E.; Lepihina, O. Y.; Ignatova, V. V.

    2018-05-01

    The paper presents the results of the research devoted to the development of a model of information support of monitoring buildings technical condition; these buildings are located in the construction risk area. As a result of the visual and instrumental survey, as well as the analysis of existing approaches and techniques, attributive and cartographic databases have been created. These databases allow monitoring defects and damages of buildings located in a 30-meter risk area from the object under construction. The classification of structures and defects of these buildings under survey is presented. The functional capabilities of the developed model and the field of it practical applications are determined.

  14. Occluded object reconstruction for first responders with augmented reality glasses using conditional generative adversarial networks

    OpenAIRE

    Yun, Kyongsik; Lu, Thomas; Chow, Edward

    2018-01-01

    Firefighters suffer a variety of life-threatening risks, including line-of-duty deaths, injuries, and exposures to hazardous substances. Support for reducing these risks is important. We built a partially occluded object reconstruction method on augmented reality glasses for first responders. We used a deep learning based on conditional generative adversarial networks to train associations between the various images of flammable and hazardous objects and their partially occluded counterparts....

  15. The probability of reinforcement per trial affects posttrial responding and subsequent extinction but not within-trial responding.

    Science.gov (United States)

    Harris, Justin A; Kwok, Dorothy W S

    2018-01-01

    During magazine approach conditioning, rats do not discriminate between a conditional stimulus (CS) that is consistently reinforced with food and a CS that is occasionally (partially) reinforced, as long as the CSs have the same overall reinforcement rate per second. This implies that rats are indifferent to the probability of reinforcement per trial. However, in the same rats, the per-trial reinforcement rate will affect subsequent extinction-responding extinguishes more rapidly for a CS that was consistently reinforced than for a partially reinforced CS. Here, we trained rats with consistently and partially reinforced CSs that were matched for overall reinforcement rate per second. We measured conditioned responding both during and immediately after the CSs. Differences in the per-trial probability of reinforcement did not affect the acquisition of responding during the CS but did affect subsequent extinction of that responding, and also affected the post-CS response rates during conditioning. Indeed, CSs with the same probability of reinforcement per trial evoked the same amount of post-CS responding even when they differed in overall reinforcement rate and thus evoked different amounts of responding during the CS. We conclude that reinforcement rate per second controls rats' acquisition of responding during the CS, but at the same time, rats also learn specifically about the probability of reinforcement per trial. The latter learning affects the rats' expectation of reinforcement as an outcome of the trial, which influences their ability to detect retrospectively that an opportunity for reinforcement was missed, and, in turn, drives extinction. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  16. Pedestrian wind environment around tall buildings

    NARCIS (Netherlands)

    Stathopoulos, T.; Blocken, B.; Tamura, Yukio; Yoshie, Ryuichiro

    2016-01-01

    Pedestrian-level wind conditions around tall buildings are described by examining the aerodynamics of the urban environment and the various wind comfort criteria established in the wind engineering field. Experimental and, possibly, computational assessment of pedestrian-level wind conditions in the

  17. Method for Cost-Benefit Analysis of Improved Indoor Climate Conditions and Reduced Energy Consumption in Office Buildings

    Directory of Open Access Journals (Sweden)

    Viktoras Dorosevas

    2013-09-01

    Full Text Available Indoor climate affects health and productivity of the occupants in office buildings, yet in many buildings of this type indoor climate conditions are not well-controlled due to insufficient heating or cooling capacity, high swings of external or internal heat loads, improper control or operation of heating, ventilation and air conditioning (HVAC equipment, etc. However, maintenance of good indoor environmental conditions in buildings requires increased investments and possible higher energy consumption. This paper focuses on the relation between investment costs for retrofitting HVAC equipment as well as decreased energy use and improved performance of occupants in office buildings. The cost-benefit analysis implementation algorithm is presented in this paper, including energy survey of the building, estimation of occupants dissatisfied by key indoor climate indicators using questionnaire survey and measurements. Technique for Order Preference by Similarity to Ideal Solution (TOPSIS analysis is used in the proposed method for data processing. A case study of an office building is presented in order to introduce an application example of the proposed method. Results of the study verify the applicability of the proposed algorithm and TOPSIS analysis as a practical tool for office building surveys in order to maximize productivity by means of cost efficient technical building retrofitting solutions.

  18. 3D thermal climate monitoring in factory buildings

    NARCIS (Netherlands)

    Posselt, G.; Booij, P.S.; Thiede, S.; Fransman, J.E.; Driessen, B.J.F.; Herrmann, C.

    2015-01-01

    Guaranteeing defined conditions, such as the temperature levels inside the factory's building shell, is often important to produce high-quality products. Heating, ventilation and air conditioning (HVAC) equipment, as part of the technical building services, is energy intensive and accounts for a

  19. Potential Retrofit of Existing Sultan Ismail Parliament Building, Johor to Green Building

    Directory of Open Access Journals (Sweden)

    Yasin Mohd Norazam

    2017-01-01

    Full Text Available The concept of retrofitting an existing building towards green building was introduced to move towards greener development. This paper investigates the benefits of retrofitting an existing building to green building. The potential retrofit of the existing Sultan Ismail Parliament building was also determined and later the elements of the building to be retrofitted were proposed. The Sultan Ismail Parliament building is one of the newest development that serves as the Johor state administrative center under Iskandar Malaysia. Therefore, this paper focuses on whether the existing building has fulfilled all of the green building elements. A set of questionnaire was distributed to the targeted respondents who were the engineers, architects, technicians, staffs and those who were involved in the development of the Sultan Ismail Parliament building. A total of 60 respondents was involved. Based on the analyzed data, it shows that the existing building has fulfilled only one of the green building elements which is the Indoor Environmental Quality. The items that scored 3.5 and above mean index under this element include the daylight glare is not bothering, the ventilation in the building is adequate, inspections are done regularly, smoking regulation is implemented and the number of openings of windows and doors is sufficient. While it shows that other elements were only partially fulfilled. The criteria that achieved below 3.5 mean index values is considered to be the potential elements that could be used for future retrofitting initiative.

  20. Indoor environmental and air quality characteristics, building-related health symptoms, and worker productivity in a federal government building complex.

    Science.gov (United States)

    Lukcso, David; Guidotti, Tee Lamont; Franklin, Donald E; Burt, Allan

    2016-01-01

    Building Health Sciences, Inc. (BHS), investigated environmental conditions by many modalities in 71 discreet areas of 12 buildings in a government building complex that had experienced persistent occupant complaints despite correction of deficiencies following a prior survey. An online health survey was completed by 7,637 building occupants (49% response rate), a subset of whom voluntarily wore personal sampling apparatus and underwent medical evaluation. Building environmental measures were within current standards and guidelines, with few outliers. Four environmental factors were consistently associated with group-level building-related health complaints: physical comfort/discomfort, odor, job stress, and glare. Several other factors were frequently commented on by participants, including cleanliness, renovation and construction activities, and noise. Low relative humidity was significantly associated with lower respiratory and "sick building syndrome"-type symptoms. No other environmental conditions (including formaldehyde, PM10 [particulate matter with an aerodynamic diameter work but at reduced capacity), and increase in reported symptom-days, including symptoms not related to respiratory disease. We found that in buildings without unusual hazards and with environmental and air quality indicators within the range of acceptable indoor air quality standards, there is an identifiable population of occupants with a high prevalence of asthma and allergic disease who disproportionately report discomfort and lost productivity due to symptoms and that in "normal" buildings these outcome indicators are more closely associated with host factors than with environmental conditions. We concluded from the experience of this study that building-related health complaints should be investigated at the work-area level and not at a building-wide level. An occupant-centric medical evaluation should guide environmental investigations, especially when screening results of building

  1. Natural radioactivity level of main building materials in Baotou, China

    International Nuclear Information System (INIS)

    Zhao Caifeng; Lu Xinwei; Li Nan; Yang Guang

    2012-01-01

    A survey was done on natural radioactivity level and annual effective dose rate of main building materials in Baotou, China. The natural radionuclides of 40 K, 232 Th and 226 Ra in main building materials collected from Baotou were measured using NaI γ-ray spectrometry and the measured data were analyzed according to the national standards and radiological protection principles of the European Commission. The specific activities of 40 K, 232 Th and 226 Ra in the building materials samples were 218.82-1145.92, 19.75-1.32.50 and 11.46-82.66 Bq/kg, respectively. The internal and external exposure indexes of building materials were 0.06-0.41 and 0.28-0.70, respectively. The annual effective dose equivalent was 0.41-0.97 mSv/y. This justifies the production and sale of the main building materials, as both the internal and external exposure indexes of building materials are less than 1. The effective dose rate of ash brick is 0.97 mSv/y, while the maximum acceptable value is 1 mSv/y. Therefore, it is necessary to control the amount of industrial waste residue in building materials to avoid unnecessary radioactive exposure to residents. (authors)

  2. Failure Mode Estimation of Wolsong Unit 1 Containment Building with respect to Severe Accident Condition

    International Nuclear Information System (INIS)

    Hahm, Dae Gi; Choi, In Kil

    2009-01-01

    The containment buildings in a nuclear power plant (NPP) are final barriers against the exposure of harmful radiation materials at severe accident condition. Since the accident at Three Mile Island nuclear plant in 1979, it has become necessary to evaluate the internal pressure capacity of the containment buildings for the assessment of the safety of nuclear power plants. According to this necessity, many researchers including Yonezawa et al. and Hu and Lin analyzed the ultimate capacity of prestressed concrete containments subjected to internal pressure which can be occurred at sever accident condition. Especially in Wolsong nuclear power plant, the Unit 1 containment structures were constructed in the late 1970 to early 1980, so that the end of its service life will be reached in near future. Since that the complete decommission and reconstruction of the NPP may cause a huge expenses, an extension of the service time can be a cost-effective alternative. To extend the service time of NPP, an overall safety evaluation of the containment building under severe accident condition should be performed. In this study, we assessed the pressure capacity of Wolsong Unit 1 containment building under severe accident, and estimated the responses at all of the probable critical areas. Based on those results, we found the significant failure modes of Wolsong Unit 1 containment building with respect to the severe accident condition. On the other hand, for the aged NPP, the degradation of their structural performance must also be explained in the procedure of the internal pressure capacity evaluation. Therefore, in this study, we performed a parametric study on the degradation effects and evaluated the internal pressure capacity of Wolsong Unit 1 containment building with considering aging and degradation effects

  3. Contextual change after fear acquisition affects conditioned responding and the time course of extinction learning – Implications for renewal research

    Directory of Open Access Journals (Sweden)

    Rachel eSjouwerman

    2015-12-01

    Full Text Available Context plays a central role in retrieving (fear memories. Accordingly, context manipulations are inherent to most return of fear (ROF paradigms (in particular renewal, involving contextual changes after fear extinction. Context changes are, however, also often embedded during earlier stages of ROF experiments such as context changes between fear acquisition and extinction (e.g. in ABC and ABA renewal. Previous studies using these paradigms have however focused exclusively on the context switch after extinction (i.e. renewal. Thus, the possibility of a general effect of a context switch on conditioned responding that may not be conditional to preceding extinction learning remains unstudied.Hence, the current study investigated the impact of a context switch between fear acquisition and extinction on immediate conditioned responding and on the time-course of extinction learning by using a multimodal approach. A group that underwent contextual change after fear conditioning (AB; n = 36 was compared with a group without a contextual change from acquisition to extinction (AA; n = 149, while measuring autonomic (skin conductance and fear potentiated startle measures and subjective fear ratings. Contextual change between fear acquisition and extinction had a pronounced effect on both immediate conditioned responding and on the time course of extinction learning in skin conductance responses and subjective fear ratings. This may have important implications for the mechanisms underlying and the interpretation of the renewal effect (i.e. contextual switch after extinction. Consequently, future studies should incorporate designs and statistical tests that disentangle general effects of contextual change from genuine ROF effects.

  4. University building safety index measurement using risk and implementation matrix

    Science.gov (United States)

    Rahman, A.; Arumsari, F.; Maryani, A.

    2018-04-01

    Many high rise building constructed in several universities in Indonesia. The high-rise building management must provide the safety planning and proper safety equipment in each part of the building. Unfortunately, most of the university in Indonesia have not been applying safety policy yet and less awareness on treating safety facilities. Several fire accidents in university showed that some significant risk should be managed by the building management. This research developed a framework for measuring the high rise building safety index in university The framework is not only assessed the risk magnitude but also designed modular building safety checklist for measuring the safety implementation level. The safety checklist has been developed for 8 types of the university rooms, i.e.: office, classroom, 4 type of laboratories, canteen, and library. University building safety index determined using risk-implementation matrix by measuring the risk magnitude and assessing the safety implementation level. Building Safety Index measurement has been applied in 4 high rise buildings in ITS Campus. The building assessment showed that the rectorate building in secure condition and chemical department building in beware condition. While the library and administration center building was in less secure condition.

  5. Stomata of the CAM plant Tillandsia recurvata respond directly to humidity.

    Science.gov (United States)

    Lange, O L; Medina, E

    1979-01-01

    Under controlled conditions, CO 2 exchange of Tillandsia recurvata showed all characteristics of CAM. During the phase of nocturnal CO 2 fixation stomata of the plant responded sensitively to changes in ambient air humidity. Dry air resulted in an increase, moist air in a decrease of diffusion resistance. The evaporative demand of the air affected the level of stomatal resistance during the entire night period. Due to stomatal closure, the total nocturnal water loss of T. recurvata was less at low than at high humidity. It is concluded that stomata respond directly to humidity and not via bulk tissue water conditions of the leaves. Such control of transpiration may optimize water use efficiency for this almost rootless, extreme epiphyte.

  6. Energy efficiency index to artificially conditioned buildings; Indice de eficiencia energetica para edificios climatizados artificialmente

    Energy Technology Data Exchange (ETDEWEB)

    Jota, Patricia Romeiro da Silva; Santos, Carla da Silva; Costa, Kelly Luciene C. [Centro Federal de Educacao Tecnologica de Minas Gerais (CEMIG/CEFET), Belo Horizonte, MG (Brazil). Centro de Pesquisa em Energia Inteligente

    2010-07-01

    Conditioning buildings has been growing in number and are responsible for a significant portion of the energy used worldwide. The building energy use can be measured by the index of energy performance and specific fuel consumption (EC). The specific consumption is an index where the energy is normalized by the factors that affect energy use in order to obtain an index to explain variations in consumption. In this paper, we present a methodology to obtain a specific consumption that takes into account one of the factors that most affect energy use in these buildings, that is, the external temperature. The study is based on analysis of consumption of air conditioning system according to temperature. Through this analysis we obtain a function to facilitate the standardization of energy use, depending on the temperature outside. This methodology was tested in previous work on real buildings without stratification of energy, and this work will be presented a case study of a building whose energy measurement is stratified. The proposed index is the ratio between the energy consumption of air conditioning system corrected by the temperature through the function K(T). It was possible to demonstrate the efficiency of the index to eliminate the effect of temperature and thus to evaluate the evolution of specific consumption over the months analyzed. (author)

  7. Case Study of a Nearly Zero Energy Building in Italian Climatic Conditions

    Directory of Open Access Journals (Sweden)

    Hassan Saeed Khan

    2017-11-01

    Full Text Available The building sector is an important stakeholder in the energy and environmental scenario of any country. It continues to grow across the world due to factors such as population growth, and economic and infrastructure development. Within the European Union, buildings account for 40% of the total energy requirements and 30% of carbon dioxide emissions. The building sector is keen to improve its sustainability standards and also to help achieve the 20-20-20 targets set by the European Union. The present work aims to design a nearly zero energy sports gymnasium building in Calolziocorte, Italy. Various sustainability techniques are applied in an integrated design project approach using ECOTECT software to undertake the energy modelling exercise. Firstly, the base-case is modelled with conventional building materials and the total energy demand is calculated. Duly considering the local climatic conditions, sustainable materials are chosen for walls, the floor, the roof, and windows and a 38% reduction is noted in the total energy demand of the building compared to the base-case. The impact of louvers as a passive design technique has also been examined on the total energy demand of the building. The monthly load/discomfort analysis is undertaken for various individual functions inside the building to identify the critical areas that consume more energy. The monthly load/discomfort analysis is performed with the proposed materials and the air infiltration rate is improved through the building envelope and 63% reduction is noted in the total energy demand of the building compared to the base-case. A solar access analysis is conducted to understand the on-site energy production and then the building net energy demand is calculated, which is reduced to 90% compared to the base-case.

  8. Regulation proposal for voluntary energy efficiency labelling of commercial buildings

    International Nuclear Information System (INIS)

    Lamberts, Roberto; Goulart, Solange; Carlo, Joyce; Westphal, Fernando

    2006-01-01

    Despite of Brazil not being between the major world energy consumers, the consumption of electricity has significantly increased in the late years. The National Energy Balance of 2005, published by the Brazilian Ministry of Energy, showed an increasing of the participation of electricity in the final energy consumption of 15.7% in 2002 to 16.2% in 2004. Initially, a brief review of the initiatives taken by Brazilian Government aiming to limit and control the energy consumption in buildings is presented. Then, the regulation proposal containing the technical requirements to classify the energy efficiency level of buildings is shown. The purpose of this voluntary regulation is to provide conditions to certify the energy efficiency level of Brazilian buildings (commercial and public). It specifies the methods for energy efficiency rating of buildings and includes requirements to attend energy conservation measures in three main issues: lighting system; air conditioning system and envelope. The regulation applies to large buildings (minimum total area of 500 m 2 or when the energy demand is greater than or equal to 2,3 kV, including: Conditioned buildings; Partially conditioned buildings and Naturally ventilated buildings. (author)

  9. Quantification of mold contamination in multi-level buildings using the Environmental Relative Moldiness Index

    Science.gov (United States)

    The goal of this study was to evaluate the possible use of the Environmental Relative Moldiness Index (ERMI) to quantify mold contamination in multi-level, office buildings. Settled-dust samples were collected in multi-level, office buildings and the ERMI value for each sample de...

  10. Energy efficient hybrid nanocomposite-based cool thermal storage air conditioning system for sustainable buildings

    International Nuclear Information System (INIS)

    Parameshwaran, R.; Kalaiselvam, S.

    2013-01-01

    The quest towards energy conservative building design is increasingly popular in recent years, which has triggered greater interests in developing energy efficient systems for space cooling in buildings. In this work, energy efficient silver–titania HiTES (hybrid nanocomposites-based cool thermal energy storage) system combined with building A/C (air conditioning) system was experimentally investigated for summer and winter design conditions. HiNPCM (hybrid nanocomposite particles embedded PCM) used as the heat storage material has exhibited 7.3–58.4% of improved thermal conductivity than at its purest state. The complete freezing time for HiNPCM was reduced by 15% which was attributed to its improved thermophysical characteristics. Experimental results suggest that the effective energy redistribution capability of HiTES system has contributed for reduction in the chiller nominal cooling capacity by 46.3% and 39.6% respectively, under part load and on-peak load operating conditions. The HiTES A/C system achieved 27.3% and 32.5% of on-peak energy savings potential in summer and winter respectively compared to the conventional A/C system. For the same operating conditions, this system yield 8.3%, 12.2% and 7.2% and 10.2% of per day average and yearly energy conservation respectively. This system can be applied for year-round space conditioning application without sacrificing energy efficiency in buildings. - Highlights: • Energy storage is acquired by HiTES (hybrid nanocomposites-thermal storage) system. • Thermal conductivity of HiNPCM (hybrid nanocomposites-PCM) was improved by 58.4%. • Freezing time of HiNPCM was reduced by 15% that enabled improved energy efficiency. • Chiller nominal capacity was reduced by 46.3% and 39.6% in on-peak and part load respectively. • HiTES A/C system achieved appreciable energy savings in the range of 8.3–12.2%

  11. Performance advancement of solar air-conditioning through integrated system design for building

    International Nuclear Information System (INIS)

    Fong, K.F.; Lee, C.K.

    2014-01-01

    This study is to advance the energy performance of solar air-conditioning system through appropriate component integration from the absorption refrigeration cycle and proper high-temperature cooling. In the previous studies, the solar absorption air-conditioning using the working pair of water – lithium bromide (H 2 O–LiBr) is found to have prominent primary energy saving than the conventional compression air-conditioning for buildings in the hot-humid climate. In this study, three integration strategies have been generated for solar cooling, namely integrated absorption air-conditioning; integrated absorption-desiccant air-conditioning; and integrated absorption-desiccant air-conditioning for radiant cooling. To realize these ideas, the working pair of ammonia – water (NH 3 –H 2 O) was used in the absorption cycle, rather than H 2 O–LiBr. As such, the evaporator and the condenser can be separate from the absorption refrigeration cycle for the new configuration of various integrated design alternatives. Through dynamic simulation, the year-round primary energy saving of the proposed integration strategies for solar NH 3 –H 2 O absorption air-conditioning systems could be up to 50.6% and 25.5%, as compared to the conventional compression air-conditioning and the basic solar H 2 O–LiBr absorption air-conditioning respectively. Consequently, carbon reduction of building air-conditioning can be achieved more effectively through the integrated system design in the hot and humid cities. - Highlights: • Three integration strategies, IAAU, IADAU and IADAU-RC, are proposed to advance solar air-conditioning. • NH 3 –H 2 O is adopted for absorption refrigeration instead of H 2 O–LiBr. • Separate evaporator and condenser, desiccant cooling and radiant cooling are designed for IADAU-RC. • IADAU-RC can have 50.6% primary energy saving against the conventional air-conditioning

  12. Improving PAQ and comfort conditions in Spanish office buildings with passive climate control

    Energy Technology Data Exchange (ETDEWEB)

    Orosa, Jose A.; Baalina, A. [Departamento de Energia y P.M. Escuela Tecnica Superior de N. y M, Universidade da Coruna, Paseo de Ronda 51, P.C.:15011 A Coruna (Spain)

    2009-03-15

    Some researchers have demonstrated that passive moisture transfer between indoor air and hygroscopic structures has the potential to moderate variations of indoor air relative humidity and, thus, to improve comfort and PAQ [Simonson CJ, Salonvaara M, Ojalen T. The effect of structures on indoor humidity-possibility to improve comfort and perceived air quality. Indoor Air 2002; 12: 243-51; Simonson CJ, Salonvaara M, Ojalen T. Improving indoor climate and comfort with wooden structures. Espoo 2001. Technical Research Centre of Finland, VTT Publications 431.200p+app 91p]. The main objective of this study is to show the internal wall coating effect on indoor air conditions and, as a consequence of this, in comfort conditions and PAQ. In a previous paper [Orosa JA, Baalina A. Passive climate control in Spanish office buildings for long periods of time. Building and Environment 2008], we analysed the influence of permeable and impermeable materials on indoor air conditions, during the unoccupied period, in 25 office buildings in different seasons. Results obtained lead us to conclude that real coverings such as permeable, semi-permeable and impermeable types, present different behavioural patterns in indoor air conditions. Furthermore, we concluded that an absorbent structure will moderate relative humidity indoors. In this paper, we study this indoor relative humidity effect on local thermal discomfort, due to decreased respiratory cooling, and indoor ambience acceptability for the early hours of morning applying PD and Acc models [Toftum J, Jorgensen AS, Fanger PO. Upper limits for indoor air humidity to avoid uncomfortably humid skin. Energy and buildings 1998; 28: 1-13; Toftum J, Jorgensen AS, Fanger PO. Upper limits of air humidity for preventing warm respiratory discomfort. Energy and Buildings 1998; 28: 15-23] such as that proposed by Simonson et al. [The effect of structures on indoor humidity-possibility to improve comfort and perceived air quality. Indoor Air

  13. 324 Building radiochemical engineering cells, high-level vault, low-level vault, and associated areas closure plan

    International Nuclear Information System (INIS)

    Barnett, J.M.

    1998-01-01

    The Hanford Site, located adjacent to and north of Richland, Washington, is operated by the US Department of Energy, Richland Operations Office (RL). The 324 Building is located in the 300 Area of the Hanford Site. The 324 Building was constructed in the 1960s to support materials and chemical process research and development activities ranging from laboratory/bench-scale studies to full engineering-scale pilot plant demonstrations. In the mid-1990s, it was determined that dangerous waste and waste residues were being stored for greater than 90 days in the 324 Building Radiochemical Engineering Cells (REC) and in the High-Level Vault/Low-Level Vault (HLV/LLV) tanks. [These areas are not Resource Conservation and Recovery Act of 1976 (RCRA) permitted portions of the 324 Building.] Through the Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) Milestone M-89, agreement was reached to close the nonpermitted RCRA unit in the 324 Building. This closure plan, managed under TPA Milestone M-20-55, addresses the identified building areas targeted by the Tri-Party Agreement and provides commitments to achieve the highest degree of compliance practicable, given the special technical difficulties of managing mixed waste that contains high-activity radioactive materials, and the physical limitations of working remotely in the areas within the subject closure unit. This closure plan is divided into nine chapters. Chapter 1.0 provides the introduction, historical perspective, 324 Building history and current mission, and the regulatory basis and strategy for managing the closure unit. Chapters 2.0, 3.0, 4.0, and 5.0 discuss the detailed facility description, process information, waste characteristics, and groundwater monitoring respectively. Chapter 6.0 deals with the closure strategy and performance standard, including the closure activities for the B-Cell, D-Cell, HLV, LLV; piping and miscellaneous associated building areas. Chapter 7.0 addresses the

  14. Treatment and conditioning of metallic intermediate level waste

    International Nuclear Information System (INIS)

    Lidar, Per; Larsson, Arne; Huutoniemi, Tommi; Blank, Eva; Elfwing, Mattias

    2014-01-01

    In 2011 SKB started an R and D program for evaluating different disposal concepts for LL-LILW. The purpose was to develop alternative repository concepts and conditioning methods for LL-LILW and to evaluate and compare them from a range of parameters. The goal is to present a comparison between identified repository concepts by 2013. The material should be of such a quality that SKB can make decisions of which concepts that are to be further investigated in a safety analysis. As a part of the R and D program for the LL-LILW disposal facility, Studsvik was assigned to investigate whether melting of metallic LL-LILW is technically feasible and, if so, what the requirements are to build and operate such a facility. Specific concern was given to the following metallic components: - Core components and reactor internals from both boiling water reactors (BWRs) and pressurized water reactors (PWRs). - Reactor pressure vessels from PWRs. The paper presents a feasibility study of a melting facility for core components and reactor internals. An overview is given of how such a facility for treatment of intermediate level waste might be designed, constructed and operated and highlights both the possibilities and challenges. A cost estimate and a risk analysis are presented in order to make a conclusion of the technical feasibility of such a facility. Based on the Studsvik authors' experience in operating a low level waste melting facility, their conclusion is presented in the paper, considering cost of constructing and operating such a facility, in conjunction with the radio-logical risks associated with operation and the benefits to disposal and long term safety. Studsvik also investigated alternative techniques for embedding of metallic ILW components. Embedding of radioactive metallic ILW components protects the component from corrosion and leakage of radionuclides from repository to biosphere can thereby be both delayed and decreased. Conditioning by embedding has

  15. Fundamental Characteristics For Building Dymanics Obtained From Microtremors Measurements.

    Science.gov (United States)

    Enomoto, T.; Abeki, N.; Kuramochi, D.; Lanuza, A.; Gonzalez, J.; Schmitz, M.; Navarro, M.

    We are performing the international joint research investigations for the seismic disaster mitigation in Metro Manila between Philippine and Japan from 1994, in Caracas between Venezuela and Japan from 1996 and also in Almeria and Granada between Spain and Japan from 1996. We have made the microtremor measurements at Reinforced Concrete (RC) buildings existed in these cities and evaluated the dynamical characteristics of RC buildings, natural period and damping factor. Even if it·fs necessary to have some discussions about the accuracy of microtremor measurement in order to evaluate the dynamical characteristics because of small amplitude range phenomena. However, the microtremor measurement method is a simple, low cost and realistic method in order to observe and investigate the actual dynamical behavior for obtaining the useful information in many countries. In these international joint research works, we settled the main object to the getting useful information of building dynamical characteristics for the seismic disaster mitigation. So, we observed microtremors at the top floor of several kinds of buildings which have the different conditions, for examples, existed place, building type, dimensional scale and number of stories etc. Then we realized the evaluation of natural period and responded damping factor of building depending on the building conditions as a statistical tendencies. In this paper, mainly we would like to present the investigated results of regression relationship between the natural period of RC building and the number of stories in Philippine and Venezuela, respectively. and also, we summarized the relationship between the natural period of RC building and damping factor considering the surrounding soil condition. We thought that these relations are reasonable and believable results in the small amplitude range evaluated from microtremors.

  16. Study on post occupancy evaluation after remodeling in accordance with the `green remodeling certification standards of existing non-residential buildings'- Focusing on the case of H building

    Science.gov (United States)

    Cho, Kyungjoo; Cho, Dongwoo; Yoon, Yosun

    2018-06-01

    South Korea has adopted the Paris Convention and promised to reduce greenhouse gas emissions by 37% from business-as-usual (BAU) levels in the `First Basic Plan to Respond to Climate Change'. The reduction goal of greenhouse gas cannot be achieved considering only new buildings; the analysis results shows that the reduction of greenhouse gas emissions from existing buildings is essential. `The Green Remodeling Certification Standards', established in South Korea in 2016, is in line with the above plan. The post-occupancy evaluation (POE) of remodeled buildings after applying the `Green Remodeling Certification Standards of Existing Buildings' must be studied for expansion of this scheme. The study results are expected to be used as foundational data for the promotion of remodeling existing buildings.

  17. Roadmap-Based Level Clearing of Buildings

    KAUST Repository

    Rodriguez, Samuel

    2011-01-01

    In this paper we describe a roadmap-based approach for a multi-agent search strategy to clear a building or multi-story environment. This approach utilizes an encoding of the environment in the form of a graph (roadmap) that is used to encode feasible paths through the environment. The roadmap is partitioned into regions, e.g., one per level, and we design region-based search strategies to cover and clear the environment. We can provide certain guarantees within this roadmap-based framework on coverage and the number of agents needed. Our approach can handle complex and realistic environments where many approaches are restricted to simple 2D environments. © 2011 Springer-Verlag.

  18. Building without a plan: the career experiences of Australian strength and conditioning coaches.

    Science.gov (United States)

    Dawson, Andrew J; Leonard, Zane M; Wehner, Kylie A; Gastin, Paul B

    2013-05-01

    The purpose of this investigation was to explore the career experiences of Australian strength and conditioning coaches. Six Australian strength and conditioning coaches (mean age = 33.7 years, SD = 6.0 years) with a mean of 10.4 (SD = 4.9) years experience working with elite Olympic and professional athletes were interviewed about their experiences of career development. Each interview was transcribed verbatim and analyzed to produce key themes and subthemes relating to (a) work environments, (b) sport management practice, (c) career development processes, and (d) career building strategies. The work environments of Australian strength and conditioning coaches were found to be poor because of long working hours and irregular human resource policy and management practices of sport organizations. Because of the volatile and unpredictable nature of their working conditions, the coaches interviewed have only a short-term view of their career creating considerable stress in their lives. The coaches interviewed found it difficult to develop their careers because their only options were self-supported and self-funded professional development activities. The coaches in this study believed that more needed to be done at a policy and management level by sport organizations and their professional body to enhance the career development of strength and conditioning coaches because they play a key role in both athlete and sport organization performance. These results may help sport organizations develop policies and management practices that enhance the careers of strength and conditioning coaches and will have important practical implications for the education and development of sport professionals.

  19. Vision-based building energy diagnostics and retrofit analysis using 3D thermography and building information modeling

    Science.gov (United States)

    Ham, Youngjib

    localization issues of 2D thermal image-based inspection, a new computer vision-based method is presented for automated 3D spatio-thermal modeling of building environments from images and localizing the thermal images into the 3D reconstructed scenes, which helps better characterize the as-is condition of existing buildings in 3D. By using these models, auditors can conduct virtual walk-through in buildings and explore the as-is condition of building geometry and the associated thermal conditions in 3D. Second, to address the challenges in qualitative and subjective interpretation of visual data, a new model-based method is presented to convert the 3D thermal profiles of building environments into their associated energy performance metrics. More specifically, the Energy Performance Augmented Reality (EPAR) models are formed which integrate the actual 3D spatio-thermal models ('as-is') with energy performance benchmarks ('as-designed') in 3D. In the EPAR models, the presence and location of potential energy problems in building environments are inferred based on performance deviations. The as-is thermal resistances of the building assemblies are also calculated at the level of mesh vertex in 3D. Then, based on the historical weather data reflecting energy load for space conditioning, the amount of heat transfer that can be saved by improving the as-is thermal resistances of the defective areas to the recommended level is calculated, and the equivalent energy cost for this saving is estimated. The outcome provides building practitioners with unique information that can facilitate energy efficient retrofit decision-makings. This is a major departure from offhand calculations that are based on historical cost data of industry best practices. Finally, to improve the reliability of BIM-based energy performance modeling and analysis for existing buildings, a new model-based automated method is presented to map actual thermal resistance measurements at the level of 3D vertexes to the

  20. ITER Building Design (D230-B), Task No. 28. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-01

    The International Thermonuclear Experimental Reactor (ITER) Project requires a set of buildings, each with its own distinct function, to support ITER`s mission. The Joint Central Team (JCT) has identified all the buildings in the set and has placed them in an efficient arrangement on the site. The JCT has developed a conceptual layout of each individual building. The buildings have been categorized into two main groups: (1) {open_quotes}Level 1 Buildings{close_quotes} which are on the construction schedule critical path and (2) {open_quotes}Level 2 Buildings{close_quotes} which, while important, are not on the critical path. The buildings are further categorized according to construction material, that is, {open_quotes}reinforced concrete{close_quotes} or {open_quotes}steel-frame on concrete slab{close_quotes}. This Report responds to the Project`s request to perform the initial structural steel design for all the {open_quotes}steel-frame on concrete slab{close_quotes} buildings. Of the twelve (12) {open_quotes}steel-frame on concrete slab{close_quotes} buildings, four (4) are Level 1 and eight (8) are Level 2 Buildings. This Report is a deliverable for the ITER Task Assignment entitled {open_quotes}ITER Buildings Design (D230-B){close_quotes}, also designated as Task No. 28. ITER U.S. Home Team Industrial Consortium members, Raytheon Engineers & Constructors (RE&C) and Stone & Webster Engineering Corporation (SWEC), teamed to perform Task 28. This task commenced in May 1995. It was performed in accordance with the design criteria specified by the ITER-JCT, San Diego Joint Work Site.

  1. Manual for first responders to a radiological emergency. Emergency preparedness and response

    International Nuclear Information System (INIS)

    2008-01-01

    Under Article 5.a(ii) of the Convention on Assistance in the Case of a Nuclear Accident or Radiological Emergency (Assistance Convention), one function of the IAEA is to collect and disseminate to States Parties and Member States information concerning methodologies, techniques and results of research relating to response to nuclear or radiological emergencies. As stated in IAEA Safety Standards Series No. GS-R-2 'Preparedness and Response for a Nuclear or Radiological Emergency', which establishes the requirements for an adequate level of preparedness for and response to a nuclear or radiological emergency in any State, 'first responders shall take all practicable and appropriate actions to minimize the consequences of a nuclear or radiological emergency'. The IAEA General Conference, in resolution GC(49)/RES/9, continues to encourage Member States 'to adopt the relevant Agency standards, procedures and practical tools' and underlines 'the need for first responders to have appropriate training for dealing with ionizing radiation during nuclear and radiological emergencies'. This publication is intended to assist in meeting these requirements and to fulfil Article 5 of the Assistance Convention. Its aim is to provide practical guidance for those who will respond during the first few hours to a radiological emergency (referred to here as 'first responders') and for national officials who would support this early response. It provides guidance in the form of action guides, instructions, and supporting data that can be easily applied by a State to build a basic capability to respond to a radiological emergency. This guidance should be adapted to fit the user State's organizational arrangements, language, terminology, concept of operation and capabilities. This report, published as part of the IAEA Emergency Preparedness and Response Series, replaces and builds on IAEA-TECDOC-1162 in the area of early response and first responders' actions. It takes account of the

  2. AUTOMATED SYSTEM OF OPERATIONAL CONTROL HEATING AND AIR CONDITIONING OF BUILDINGS

    Directory of Open Access Journals (Sweden)

    PETRENKO A. O.

    2016-08-01

    Full Text Available Statement of the problem. Health and human performance largely determined by the conditions of climate and air quality in residential, administrative and residential and public buildings. At that, in turn, is influenced by the external environment and the climate, and the geometric dimensions of the room, and thermal performance building envelopes, and the location of the premises (Orientation, and many other factors. The result is the formation of complex systems, which control decision-making in conditions of multifactor [1]. In hygienic purposes it is necessary to strive to create the best indoor microclimate conditions, regardless of changes in the factors that affect the climate in residential, administrative and residential and public buildings. Develop systems to ensure the necessary microclimate parameters – it is a complex and important task, which will depend entirely comfortable and cozy environment for the person. The problem of the present time, there is a steady increase in the energy consumption of these systems, due to the rise in price of non-renewable energy sources, and our job is, to simulate the work of software systems necessary microclimate for the changes in the factors that affect it and to minimize the use of non-renewable energy sources. Analysis of recent research and publications. Domestic and foreign hygienists [2, 3, 4] to establish a connection between the climate in the room and in the workplace and the state of human health. Formation of the indoor climate of residential, administrative and residential and public buildings is influenced by many factors that have already noted earlier [5, 6]. Study of the processes of influence of various factors on human health is of great complexity. If we consider each process separately, and in this case they are not currently amenable to theoretical description clearer. To simulate the effect of these factors studies were conducted, which showed that, with sufficient

  3. Systolic peak detection in acceleration photoplethysmograms measured from emergency responders in tropical conditions.

    Science.gov (United States)

    Elgendi, Mohamed; Norton, Ian; Brearley, Matt; Abbott, Derek; Schuurmans, Dale

    2013-01-01

    Photoplethysmogram (PPG) monitoring is not only essential for critically ill patients in hospitals or at home, but also for those undergoing exercise testing. However, processing PPG signals measured after exercise is challenging, especially if the environment is hot and humid. In this paper, we propose a novel algorithm that can detect systolic peaks under challenging conditions, as in the case of emergency responders in tropical conditions. Accurate systolic-peak detection is an important first step for the analysis of heart rate variability. Algorithms based on local maxima-minima, first-derivative, and slope sum are evaluated, and a new algorithm is introduced to improve the detection rate. With 40 healthy subjects, the new algorithm demonstrates the highest overall detection accuracy (99.84% sensitivity, 99.89% positive predictivity). Existing algorithms, such as Billauer's, Li's and Zong's, have comparable although lower accuracy. However, the proposed algorithm presents an advantage for real-time applications by avoiding human intervention in threshold determination. For best performance, we show that a combination of two event-related moving averages with an offset threshold has an advantage in detecting systolic peaks, even in heat-stressed PPG signals.

  4. Changes in productivity, psychological wellbeing and physical wellbeing from working in a 'green' building.

    Science.gov (United States)

    Thatcher, Andrew; Milner, Karen

    2014-01-01

    Based on improvements in indoor environmental quality claims are that 'green' buildings are healthier and promote greater productivity than conventional buildings. However, the empirical evidence over the last decade has been inconclusive, usually with flawed study designs. This study explored whether a 'green' building leads to a healthier, more productive work environment. A one-year, longitudinal comparison of two groups of employees of a large commercial bank; a group that moved into a GreenStar-accredited building and a group that stayed in a conventional building, was conducted. Measures of psychological wellbeing, physical wellbeing, productivity, and perceptions of the physical environment were taken before the move, six months later, and one year later. Results indicate that the 'green' building group had significantly increased self-reported productivity and physical wellbeing. The perceptions of the physical work environment indicate that respondents in the 'green' building group experienced significant air quality improvements (specifically, reduced stale air, better ventilation, improved air movement, reduced humidity, and conditions that were not too drafty) but perceived the lighting conditions as dimmer. Despite positive findings 'green' building rating tools require amendment to focus on those qualities that actually lead to improved wellbeing and productivity.

  5. On-Site Renewable Energy and Green Buildings: A System-Level Analysis.

    Science.gov (United States)

    Al-Ghamdi, Sami G; Bilec, Melissa M

    2016-05-03

    Adopting a green building rating system (GBRSs) that strongly considers use of renewable energy can have important environmental consequences, particularly in developing countries. In this paper, we studied on-site renewable energy and GBRSs at the system level to explore potential benefits and challenges. While we have focused on GBRSs, the findings can offer additional insight for renewable incentives across sectors. An energy model was built for 25 sites to compute the potential solar and wind power production on-site and available within the building footprint and regional climate. A life-cycle approach and cost analysis were then completed to analyze the environmental and economic impacts. Environmental impacts of renewable energy varied dramatically between sites, in some cases, the environmental benefits were limited despite the significant economic burden of those renewable systems on-site and vice versa. Our recommendation for GBRSs, and broader policies and regulations, is to require buildings with higher environmental impacts to achieve higher levels of energy performance and on-site renewable energy utilization, instead of fixed percentages.

  6. Energy impact of indoor environmental policy for air-conditioned offices of Hong Kong

    International Nuclear Information System (INIS)

    Wong, L.T.; Mui, K.W.; Shi, K.L.

    2008-01-01

    Air-conditioned office buildings are one of the biggest energy consumers of electricity in developed cities in the subtropical climate regions. A good energy policy for the indoor environment should respond to both the needs of energy conservation and the needs for a desirable indoor healthy environment with a reduction in carbon dioxide (CO 2 ) generation. This study evaluates energy implications and the corresponding CO 2 generation of some indoor environmental policies for air-conditioned office buildings in the subtropical climate. In particular, the thermal energy consumption in an air-conditioned office building was evaluated by the heat gains through the building fabric, the transport of outdoor fresh air for ventilation, and the heat generated by the occupant and equipment in the space. With the Monte-Carlo sampling technique and the parameters from the existing office building stocks of Hong Kong, the energy consumption profiles of air-conditioned office buildings in Hong Kong were evaluated. Energy consumption profiles were simulated for certain indoor environmental quality (IEQ) policies on indoor air temperature and CO 2 concentration settings in the offices, with other building parameters remaining unchanged. The impact assessment and the regression models described in this study may be useful for evaluation of energy performances of IEQ policies. They will also be useful for the promotion of energy-saving measures in air-conditioned office buildings in Hong Kong. This study presented a useful source of references for policymakers, building professionals and end users to quantify the energy and environmental impacts due to an IEQ policy for air-conditioned office buildings

  7. Improving building energy efficiency in India: State-level analysis of building energy efficiency policies

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Sha; Tan, Qing; Evans, Meredydd; Kyle, Page; Vu, Linh; Patel, Pralit L.

    2017-11-01

    India is expected to add 40 billion m2 of new buildings till 2050. Buildings are responsible for one third of India’s total energy consumption today and building energy use is expected to continue growing driven by rapid income and population growth. The implementation of the Energy Conservation Building Code (ECBC) is one of the measures to improve building energy efficiency. Using the Global Change Assessment Model, this study assesses growth in the buildings sector and impacts of building energy policies in Gujarat, which would help the state adopt ECBC and expand building energy efficiency programs. Without building energy policies, building energy use in Gujarat would grow by 15 times in commercial buildings and 4 times in urban residential buildings between 2010 and 2050. ECBC improves energy efficiency in commercial buildings and could reduce building electricity use in Gujarat by 20% in 2050, compared to the no policy scenario. Having energy codes for both commercial and residential buildings could result in additional 10% savings in electricity use. To achieve these intended savings, it is critical to build capacity and institution for robust code implementation.

  8. The importance of moisture buffering for indoor climate and energy conditions of buildings

    DEFF Research Database (Denmark)

    Rode, Carsten; Grau, Karl

    2007-01-01

    A new Nordic test method specifies a test protocol for determination of the so-called Moisture Buffer Value (MBV) of building materials. But how important is moisture buffering to determine the indoor humidity condition of buildings? The paper will present the new MBV-definition. Although...... buffering to save energy by reducing the requirement for ventilation in periods, and still maintain the same quality of the indoor climate? The paper will outline some possibilities for analytical/numerical calculations, and will answer some of the posed questions on the probable benefit of taking moisture...

  9. Optimization and Performance Study of Select Heating Ventilation and Air Conditioning Technologies for Commercial Buildings

    Science.gov (United States)

    Kamal, Rajeev

    Buildings contribute a significant part to the electricity demand profile and peak demand for the electrical utilities. The addition of renewable energy generation adds additional variability and uncertainty to the power system. Demand side management in the buildings can help improve the demand profile for the utilities by shifting some of the demand from peak to off-peak times. Heating, ventilation and air-conditioning contribute around 45% to the overall demand of a building. This research studies two strategies for reducing the peak as well as shifting some demand from peak to off-peak periods in commercial buildings: 1. Use of gas heat pumps in place of electric heat pumps, and 2. Shifting demand for air conditioning from peak to off-peak by thermal energy storage in chilled water and ice. The first part of this study evaluates the field performance of gas engine-driven heat pumps (GEHP) tested in a commercial building in Florida. Four GEHP units of 8 Tons of Refrigeration (TR) capacity each providing air-conditioning to seven thermal zones in a commercial building, were instrumented for measuring their performance. The operation of these GEHPs was recorded for ten months, analyzed and compared with prior results reported in the literature. The instantaneous COPunit of these systems varied from 0.1 to 1.4 during typical summer week operation. The COP was low because the gas engines for the heat pumps were being used for loads that were much lower than design capacity which resulted in much lower efficiencies than expected. The performance of equivalent electric heat pump was simulated from a building energy model developed to mimic the measured building loads. An economic comparison of GEHPs and conventional electrical heat pumps was done based on the measured and simulated results. The average performance of the GEHP units was estimated to lie between those of EER-9.2 and EER-11.8 systems. The performance of GEHP systems suffers due to lower efficiency at

  10. The Influence of the Technical Condition of a Building on the Property’s Market Value

    Directory of Open Access Journals (Sweden)

    Ziembicka Beata

    2016-12-01

    Full Text Available The housed property’s market value is influenced by a set of characteristic qualities, among which is the technical condition of a building. The aim of this paper is to study the influence of the technical condition of a building on the market price of the dwelling units, depending, among others, on the chosen method and the approach to the assessment of the housing wear degree. The analysis has been performed based on the estimation of the market value of an illustrative dwelling unit located in a building erected with the use of prefabricated large panel technology in selected variants. The study is based on data from the period between January and December 2012, which are related to the sale of rights to dwelling units from the secondary market. The information was obtained from a transactional database based on the Partner Data Exchange system with the Walor software.

  11. Computer-based Monitoring for Decision Support Systems and Disaster Preparedness in Buildings

    Directory of Open Access Journals (Sweden)

    Alan Vinh

    2009-04-01

    Full Text Available The operation of modern buildings can support a vast amount of static and real-time data. Static information such as building schematics is vital for security and rescue purposes. There is a need for building managers and for first responders to be notified of designated building alerts in real-time so that actions can be performed promptly. The capability to monitor building devices and to keep the first responder community updated with the latest building information during emergency situations, as well as the ability to remotely control certain building devices and processes, can be realized today. This paper describes the various challenges encountered in the research area of building interoperability and proposes methods and insights for developing a standards framework to enable communication between building information systems and first responder information systems. Having a standards framework in place will assist in the development and deployment of commercial products in support of building interoperability.

  12. Daylighting for energy conservation in an existing building under tropical climate conditions: a case study of Lai Sue Thai building Ramkhamhaeng University

    Directory of Open Access Journals (Sweden)

    Lerdlekha Tanachaikhan

    2015-12-01

    Full Text Available Daylighting using skylight has been shown to have a high potential in reducing electrical lighting energy, and could provide a more pleasant atmosphere of a daylit space. However, in hot climates, the main constraint of daylighting is the solar heat gain that contributes to major heat load for an air-conditioning system. If the balance between the beneficial light gain used to offset lighting energy requirement and heat gain from daylight is well considered, significant energy savings can be obtained. The main objective of the study is to evaluate the potential of daylighting for energy conservation in the tropics through theoretical analysis (simulation study and experimental observation. Lai Sue Thai Building (an existing and educational building located at Ramkhamkaeng University was selected as a case study. From analysis, use of daylight could reduce electrical energy in this building by up to 76% compared to the initial condition where fully lighting was supplied. Window orientation would also play an important role. Moreover, heat gain through windows due to daylighting can be controlled by overhangs and the appropriate Window-to-Wall ratio that would be about 30% for this building. An experimental study was also carried out to validate the results in a selected room. About 49% and 37% of Relative Root Mean Square Error (RRMSE were observed in light and heat measurements, respectively

  13. Ensuring the long service life of unheated buildings. Evaluation methods to avoid moisture damage in unheated buildings

    Energy Technology Data Exchange (ETDEWEB)

    Viljanen, M.; Bergman, J.; Grabko, S.; Lu Xiaoshu; Yrjoelae, R.

    1999-07-01

    Buildings are normally designed according to an indoor temperature level of +20 deg C and to a certain ventilation rate, which depends on the activities in the building. When normal use has been interrupted and the building is left totally unheated, the indoor conditions will follow the outdoor conditions with a certain lag depending on the structures of the building and the amount of ventilation. The lowering of a room temperature increases the risk of mould and damage to structures. The research work was divided into the theoretical part and the field measurements. The objective of the research was to increase our knowledge of the thermal and moisture technical behaviour of unheated buildings, to determine the suitable methods for ensuring the preservation of buildings and their efficiency, and to develop guidelines for selecting different methods and maintenance of buildings. In the theoretical part of the research both analytical and numerical calculation programs were developed. The analytical method is based on the thermostability theory of a room and the numerical method on heat and moisture balance equations of the building. In the numerical calculation program HMTB finite difference and element methods were exploited. The accuracy of the calculation methods was compared with the field measurement results. The field measurements were carried out in eight buildings, which consisted of heated office buildings and unheated farm houses and museum buildings. The measurements were carried out during 1997 and 1998. The annual temperature range indoors in the unheated buildings was from -15 deg C to 27 deg C and the relative humidity range from 30% to 98%. In the heated buildings relative humidity was lower. The highest levels of relative humidity in the unheated buildings were in winter and in the heated buildings in autumn. The climatic differences between districts were great. Heavy rain periods increased the moisture level of indoor air by about 10 %. The risk

  14. ITER Building Design (D230-B), Task No. 28. Final report

    International Nuclear Information System (INIS)

    1995-12-01

    The International Thermonuclear Experimental Reactor (ITER) Project requires a set of buildings, each with its own distinct function, to support ITER's mission. The Joint Central Team (JCT) has identified all the buildings in the set and has placed them in an efficient arrangement on the site. The JCT has developed a conceptual layout of each individual building. The buildings have been categorized into two main groups: (1) open-quotes Level 1 Buildingsclose quotes which are on the construction schedule critical path and (2) open-quotes Level 2 Buildingsclose quotes which, while important, are not on the critical path. The buildings are further categorized according to construction material, that is, open-quotes reinforced concreteclose quotes or open-quotes steel-frame on concrete slabclose quotes. This Report responds to the Project's request to perform the initial structural steel design for all the open-quotes steel-frame on concrete slabclose quotes buildings. Of the twelve (12) open-quotes steel-frame on concrete slabclose quotes buildings, four (4) are Level 1 and eight (8) are Level 2 Buildings. This Report is a deliverable for the ITER Task Assignment entitled open-quotes ITER Buildings Design (D230-B)close quotes, also designated as Task No. 28. ITER U.S. Home Team Industrial Consortium members, Raytheon Engineers ampersand Constructors (RE ampersand C) and Stone ampersand Webster Engineering Corporation (SWEC), teamed to perform Task 28. This task commenced in May 1995. It was performed in accordance with the design criteria specified by the ITER-JCT, San Diego Joint Work Site

  15. Indoor particle levels in small- and medium-sized commercial buildings in California.

    Science.gov (United States)

    Wu, Xiangmei May; Apte, Michael G; Bennett, Deborah H

    2012-11-20

    This study monitored indoor and outdoor particle concentrations in 37 small and medium commercial buildings (SMCBs) in California with three buildings sampled on two occasions, resulting in 40 sampling days. Sampled buildings included offices, retail establishments, restaurants, dental offices, and hair salons, among others. Continuous measurements were made for both ultrafine and fine particulate matter as well as black carbon inside and outside of the building. Integrated PM(2.5), PM(2.5-10), and PM(10) samples were also collected inside and outside the building. The majority of the buildings had indoor/outdoor (I/O) particle concentration ratios less than 1.0, indicating that contributions from indoor sources are less than removal of outdoor particles. However, some of the buildings had I/O ratios greater than 1, indicating significant indoor particle sources. This was particularly true of restaurants, hair salons, and dental offices. The infiltration factor was estimated from a regression analysis of indoor and outdoor concentrations for each particle size fraction, finding lower values for ultrafine and coarse particles than for submicrometer particles, as expected. The I/O ratio of black carbon was used as a relative measure of the infiltration factor of particles among buildings, with a geometric mean of 0.62. The contribution of indoor sources to indoor particle levels was estimated for each building.

  16. Accelerometer-determined physical activity level among government employees in Penang, Malaysia.

    Science.gov (United States)

    Hazizi, A S; Aina, Mardiah B; Mohd, Nasir M T; Zaitun, Y; Hamid, Jan J M; Tabata, I

    2012-04-01

    A cross-sectional study was carried out to investigate accelerometer-determined physical activity level of 233 Malay government employees (104 men, 129 women) working in the Federal Government Building Penang, Malaysia. Body weight, height, waist and hip circumference, body fat percentage and blood pressure were measured for each respondent. All the respondents were asked to wear an accelerometer for 3 days. Body mass index (BMI) and waist-hip ratio (WHR) were calculated using a standard formulas. Fasting blood sample was obtained to determine the lipid profile and glucose levels of the respondents. Based on the accelerometer-determined physical activity level, almost 65% of the respondents were categorised as sedentary. Approximately 50.2% of the respondents were overweight or obese. There were negative but significant relationships between body mass index (BMI) (r = -0.353, p obesity in this study. The high prevalence of physical inactivity and obesity found among respondents of this study indicate a need for implementing intervention programmes among this population.

  17. THE USE OF AIR LAYERS IN BUILDING ENVELOPES FOR ENERGY SAVING DURING AIR CONDITIONING

    Directory of Open Access Journals (Sweden)

    S. N. Osipov

    2017-01-01

    Full Text Available Since there are no large natural energy resources in Belarus, energy savings ought to be a point of the special attention. With this regard it is important to develop modern ways of savings during the process of air conditioning inside new buildings with an air layer in the enclosure, especially in translucent ones. The system of ventilation of air layers in the enclosure of a building has been introduced in which air movement is caused by the gravitational and aerodynamic forces. It makes it possible to arrange further ventilation – a natural, forced or a hybrid one. With the purpose of increasing and streamlining natural draught the partitions are used separating the different parts of air layers. For natural ventilation with the use of gravitational forces the holes in the upper and lower parts of the partitions between adjacent air layers are applied. Natural ventilation in the holes of the partitions is regulated by movable shutters, blinds or other adjusting devices. For combined or forced air exchange between adjacent zones of air layers fans are used pumping air from the air layer zones with a higher temperature to zones of air layers with lower temperature and vice versa. When air exchange is forced, in order to intensify the infiltration of air into zones of air layers jets are laid on a hard surface. In order to cool a multi-layered enclosure of a building, where the movement of air between the air layers (that have been formed by internal partitions is being fulfilled by a natural, forced or combined mode, a part of the air or the total air processed inside the building (i.e. conditioned or non-conditioned air cooler as compared with the outside one is being sent to these strata. Combined or forced flow of the air processed inside the building into the air layers is done through the ducts associated with the output channels of the air conditioners. The internal partitions are equipped with the air valve hole.

  18. Please respond ASAP: workplace telepressure and employee recovery.

    Science.gov (United States)

    Barber, Larissa K; Santuzzi, Alecia M

    2015-04-01

    Organizations rely heavily on asynchronous message-based technologies (e.g., e-mail) for the purposes of work-related communications. These technologies are primary means of knowledge transfer and building social networks. As a by-product, workers might feel varying levels of preoccupations with and urges for responding quickly to messages from clients, coworkers, or supervisors--an experience we label as workplace telepressure. This experience can lead to fast response times and thus faster decisions and other outcomes initially. However, research from the stress and recovery literature suggests that the defining features of workplace telepressure interfere with needed work recovery time and stress-related outcomes. The present set of studies defined and validated a new scale to measure telepressure. Study 1 tested an initial pool of items and found some support for a single-factor structure after problematic items were removed. As expected, public self-consciousness, techno-overload, and response expectations were moderately associated with telepressure in Study 1. Study 2 demonstrated that workplace telepressure was distinct from other personal (job involvement, affective commitment) and work environment (general and ICT work demands) factors and also predicted burnout (physical and cognitive), absenteeism, sleep quality, and e-mail responding beyond those factors. Implications for future research and workplace practices are discussed. (c) 2015 APA, all rights reserved).

  19. Lighting energy efficiency in office buildings: Sri Lanka

    International Nuclear Information System (INIS)

    Wijayatunga, Priyantha D.C.; Fernando, W.J.L.S.; Ranasinghe, S.

    2003-01-01

    This paper describes a study conducted in the lighting sector of office buildings as a part of a broader research study aimed at developing building codes for Sri Lanka addressing lighting as well as thermal comfort in order to optimise the use of electricity within these buildings. The study covered different tasks performed in office buildings and the optimum lighting levels required to perform these tasks in the office environment in Sri Lanka. Also, it included assessing the visual performance of people involved in different activities under varying illumination levels in a controlled environment and a comparison of these optimum lighting levels with international standards. It can be seen that the required optimum lighting levels are generally lower in Sri Lanka in comparison to specified standard levels, and this scenario is likely to be similar in other developing countries too. These findings clearly emphasise the need to adopt lighting standards most appropriate to local conditions, in turn helping improve the energy efficiency within buildings

  20. School Facility Conditions and Student Academic Achievement

    OpenAIRE

    Earthman, Glen I.

    2002-01-01

    This paper shows that the condition of school facilities has an important impact on student performance and teacher effectiveness. In particular, research demonstrates that comfortable classroom temperature and noise level are very important to efficient student performance. The age of school buildings is a useful proxy in this regard, since older facilities often have problems with thermal environment and noise level. A number of studies have measured overall building condition and its conne...

  1. Using passive cooling strategies to improve thermal performance and reduce energy consumption of residential buildings in U.A.E. buildings

    Directory of Open Access Journals (Sweden)

    Hanan M. Taleb

    2014-06-01

    Full Text Available Passive design responds to local climate and site conditions in order to maximise the comfort and health of building users while minimising energy use. The key to designing a passive building is to take best advantage of the local climate. Passive cooling refers to any technologies or design features adopted to reduce the temperature of buildings without the need for power consumption. Consequently, the aim of this study is to test the usefulness of applying selected passive cooling strategies to improve thermal performance and to reduce energy consumption of residential buildings in hot arid climate settings, namely Dubai, United Arab Emirates. One case building was selected and eight passive cooling strategies were applied. Energy simulation software – namely IES – was used to assess the performance of the building. Solar shading performance was also assessed using Sun Cast Analysis, as a part of the IES software. Energy reduction was achieved due to both the harnessing of natural ventilation and the minimising of heat gain in line with applying good shading devices alongside the use of double glazing. Additionally, green roofing proved its potential by acting as an effective roof insulation. The study revealed several significant findings including that the total annual energy consumption of a residential building in Dubai may be reduced by up to 23.6% when a building uses passive cooling strategies.

  2. Strategic Behavior in Certifying Green Buildings: An Inquiry of the Non-building Performance Value.

    Science.gov (United States)

    Chiang Hsieh, Lin-Han; Noonan, Douglas

    2017-08-01

    This study determines the magnitude of the market signaling effect arising from Leadership in Energy and Environmental Design certification for green buildings and explores the mechanisms behind the signaling effect. Previous studies have shown that signaling or marketability plays an important role in the pursuit for Leadership in Energy and Environmental Design and equivalent green-building certification. By analyzing all new construction projects receiving Leadership in Energy and Environmental Design certification from 2000 to 2012 in the US, this study estimates the relative importance of 'green' signaling. This broad perspective using project-level data enables an analysis of some drivers of signaling and the pursuit of marketing benefits. The roles of local competition and market conditions, as well as municipal regulations are examined, especially as they differ between types of building owners (e.g., for-profit firms, governments, nonprofits). The results indicate that the non-building performance value-value captured by Leadership in Energy and Environmental Design signals above and beyond the specific building attributes that Leadership in Energy and Environmental Design certifies-dominates the attainment of Leadership in Energy and Environmental Design scores around certification tier thresholds. Further, strong evidence of spatial clustering of this non-building performance value for some owner types indicates that for-profit owners may be more responsive to local competition than non-profit owners. Local legislative mandates predict greater signaling intensity by government-owned buildings, as expected, but for-profit-owned projects tend to signal less, even after controls for local conditions. The results highlight the importance of local conditions, including peer effects and regulations, in driving non-building performance values across a wide range of green buildings.

  3. Thermo-active building systems and sound absorbers: Thermal comfort under real operation conditions

    DEFF Research Database (Denmark)

    Köhler, Benjamin; Rage, Nils; Chigot, Pierre

    2018-01-01

    Radiant systems are established today and have a high ecological potential in buildings while ensuring thermal comfort. Free-hanging sound absorbers are commonly used for room acoustic control, but can reduce the heat exchange when suspended under an active slab. The aim of this study...... is to evaluate the impact on thermal comfort of horizontal and vertical free-hanging porous sound absorbers placed in rooms of a building cooled by Thermo-Active Building System (TABS), under real operation conditions. A design comparing five different ceiling coverage ratios and two room types has been...... implemented during three measurement periods. A clear correlation between increase of ceiling coverage ratio and reduction of thermal comfort could not be derived systematically for each measurement period and room type, contrarily to what was expected from literature. In the first two monitoring periods...

  4. Measurements of radon exhalation from building materials under model climate conditions

    International Nuclear Information System (INIS)

    Jann, O.; Schneider, U.; Koeppke, J.; Lehmann, R.

    2003-01-01

    The inhalation of 222 Rn (radon) is the most important reason for lung cancer as a result of smoking. The cause for enhanced radon concentration in the air of buildings is mostly the building ground. But also building products can lead to increased radon concentrations in indoor air when the products contain raw materials or residues with higher contents of 226 Ra (radium), especially in combination with low air exchange rates. For a realistic estimation of radon concentrations it is helpful to perform emission tests on the basis of emission test chambers. Emissions test chambers are already used successfully for the measurement of volatile organic compounds (VOC) emitted from different materials and products. The analysis of radon in air was performed with a test device based on the principle of ionisation chamber (ATMOS 12 D). It could be show that radon concentrations emitted from building materials can be determined reliably if certain boundary conditions such as temperature, relative humidity and especially area specific air flow rate are met. It was also shown that reduced area specific air flow rates or reduced air exchange rates lead to higher radon concentrations. It is remarkable that no conclusion can be drawn from the activity concentration of radium to the radon concentration in the air. Therefore in some cases much higher radon concentrations in air were determined that had been expected. Obviously diffusion within the material plays an important role. (orig.)

  5. Assessment of productivity loss in air-conditioned buildings using PMV index

    Energy Technology Data Exchange (ETDEWEB)

    Kosonen, R. [Halton OY, Kausala (Finland); Tan, F. [CapitaLand Commercial Limited, Singapore (Singapore)

    2004-07-01

    This theoretical study reports on the assessment of productivity loss in air-conditioned office buildings using the PMV approach and makes use of Wyon's reviews [D.P. Wyon, P.O. Fanger, B.W. Olesen, C.J.K. Pedersen, The mental performance of subjects clothed for comfort at two different air temperatures, Ergonomics 18 (1975) 358-374; D.P. Wyon, Individual microclimate control: required range, probable benefits and current feasibility, in: Proceedings of Indoor Air '96, Institute of Public Health, Tokyo, 1996; D.P. Wyon, Indoor environmental effects on productivity. IAQ 96 Paths to better building environments/Keynote address. Y. Kevin. Atlanta, ASHRAE, pp. 5-15] as the basis to compare and to relate how the productivity loss could be minimised through improved thermal comfort design criteria. The finding shows that task-related performance is significantly correlated with the human perception of thermal environment that in turn is dependent on temperatures. Different combinations of thermal criteria (air velocity, clo, metabolic, etc.) can lead to similar PMV value and the PMV equation is useful to predict productivity loss that is due to the rate of change in thermal conditions. The study also highlights the issues that remain to be resolved in future research. (author)

  6. Do people with and without medical conditions respond similarly to the short health anxiety inventory? An assessment of differential item functioning using item response theory.

    Science.gov (United States)

    LeBouthillier, Daniel M; Thibodeau, Michel A; Alberts, Nicole M; Hadjistavropoulos, Heather D; Asmundson, Gordon J G

    2015-04-01

    Individuals with medical conditions are likely to have elevated health anxiety; however, research has not demonstrated how medical status impacts response patterns on health anxiety measures. Measurement bias can undermine the validity of a questionnaire by overestimating or underestimating scores in groups of individuals. We investigated whether the Short Health Anxiety Inventory (SHAI), a widely-used measure of health anxiety, exhibits medical condition-based bias on item and subscale levels, and whether the SHAI subscales adequately assess the health anxiety continuum. Data were from 963 individuals with diabetes, breast cancer, or multiple sclerosis, and 372 healthy individuals. Mantel-Haenszel tests and item characteristic curves were used to classify the severity of item-level differential item functioning in all three medical groups compared to the healthy group. Test characteristic curves were used to assess scale-level differential item functioning and whether the SHAI subscales adequately assess the health anxiety continuum. Nine out of 14 items exhibited differential item functioning. Two items exhibited differential item functioning in all medical groups compared to the healthy group. In both Thought Intrusion and Fear of Illness subscales, differential item functioning was associated with mildly deflated scores in medical groups with very high levels of the latent traits. Fear of Illness items poorly discriminated between individuals with low and very low levels of the latent trait. While individuals with medical conditions may respond differentially to some items, clinicians and researchers can confidently use the SHAI with a variety of medical populations without concern of significant bias. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Air leakage analysis of research reactor HANARO building in typhoon condition for the nuclear emergency preparedness

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Goany Up; Lee, Hae Cho; Kim, Bong Seok; Kim, Jong Soo; Choi, Pyung Kyu [Dept. of Emergency Preparedness, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-12-15

    To find out the leak characteristic of research reactor 'HANARO' building in a typhoon condition MELCOR code which normally is used to simulate severe accident behavior in a nuclear power plant was used to simulate the leak rate of air and fission products from reactor hall after the shutdown of the ventilation system of HANARO reactor building. For the simulation, HANARO building was designed by MELCOR code and typhoon condition passed through Daejeon in 2012 was applied. It was found that the leak rate is 0.1%·day{sup -1} of air, 0.004%·day{sup -1} of noble gas and 3.7×10{sup -5}%·day{sup -1} of aerosol during typhoon passing. The air leak rate of 0.1%·day can be converted into 1.36 m{sup 3}·hr{sup -1} , but the design leak rate in HANARO safety analysis report was considered as 600 m3·hr{sup -1} under the condition of 20 m·sec{sup -1} wind speed outside of the building by typhoon. Most of fission products during the maximum hypothesis accident at HANARO reactor will be contained in the reactor hall, so the direct radiation by remained fission products in the reactor hall will be the most important factor in designing emergency preparedness for HANARO reactor.

  8. Air leakage analysis of research reactor HANARO building in typhoon condition for the nuclear emergency preparedness

    International Nuclear Information System (INIS)

    Lee, Goany Up; Lee, Hae Cho; Kim, Bong Seok; Kim, Jong Soo; Choi, Pyung Kyu

    2016-01-01

    To find out the leak characteristic of research reactor 'HANARO' building in a typhoon condition MELCOR code which normally is used to simulate severe accident behavior in a nuclear power plant was used to simulate the leak rate of air and fission products from reactor hall after the shutdown of the ventilation system of HANARO reactor building. For the simulation, HANARO building was designed by MELCOR code and typhoon condition passed through Daejeon in 2012 was applied. It was found that the leak rate is 0.1%·day -1 of air, 0.004%·day -1 of noble gas and 3.7×10 -5 %·day -1 of aerosol during typhoon passing. The air leak rate of 0.1%·day can be converted into 1.36 m 3 ·hr -1 , but the design leak rate in HANARO safety analysis report was considered as 600 m3·hr -1 under the condition of 20 m·sec -1 wind speed outside of the building by typhoon. Most of fission products during the maximum hypothesis accident at HANARO reactor will be contained in the reactor hall, so the direct radiation by remained fission products in the reactor hall will be the most important factor in designing emergency preparedness for HANARO reactor

  9. [Hygienic assessment of a recirculatory combined air-conditioning extract-and-input system in office building].

    Science.gov (United States)

    Malysheva, A G; Abramov, E G

    2006-01-01

    The high concentrations of lead were reveled in the air and dust of some premises and on the filters of a combined air-conditioning extract-and-input system in the high-rise office buildings located in the ecologically lead favorable environment. The dust content of lead in some premises on the first floors dust was as high as 200 mg/kg, which was more than 6 times higher than that in the soil at the highway near the office buildings. The use of new technologies and devices for cleaning and optimizing the air in the premises requires analytical studies to assess the quality of the environment, by taking into account the optimal conditions of their operation.

  10. Necessity and opportunity of building a mobile facility for conditioning the spent ionic resins

    International Nuclear Information System (INIS)

    Barariu, Gheorghe

    2002-01-01

    The ionic resins utilized in nuclear industry for purification of different working fluids become contaminated by important amounts of radionuclides incorporated in their structure. Thus, these resins become intermediate-level radioactive wastes, containing radioisotopes of rather long lifetimes, and so their conditioning is required to ensure binding and isolation of the radionuclides over a period long enough, until their decay. Binding the radionuclides in stable matrices and their isolation by means of engineered barriers ensures protection of environment against contamination. In the frame of Radioactive Waste Management Program related to Cernavoda NPP, optimal technologies for processing the radioactive waste generated during the NPP operation were developed and also a site for final disposal of the low and intermediate level waste was selected. The last one is a modern, ground repository with multiple engineered barriers based on the natural properties of the host geological formation. The final disposal concept implies building a conditioning facility to ensure: a super-compacting stage of the already compacted wastes; cementing the uncompactable wastes; cementing spent filters; cementing the pellets resulted from the super-compacting stage and drums with conditioned wastes in concrete modules; cementing the organic wastes; cementing the spent ionic resins by means of a mobile facility. The spent ionic resins removed from the technologic purification systems of the station are discharged by means of demineralized water and transferred, corresponding to source, to one of the 3 storage 200 m 3 basins from the basement of the CANDU 6 NPP servicing building. To avoid the danger of spent resins being cemented at basin's bottom the basins should be emptied at every 10-15 years. To comply with IAEA requirements concerning the radioactive waste final disposal, a procedure for establishing the quantitative concentration of solidification agents and additives

  11. Issue of Building Information Modelling Implementation into the Czech Republic’s Legislation using the Level of Development

    Science.gov (United States)

    Prušková, Kristýna; Nývlt, Vladimír

    2017-10-01

    The object of this paper is the issue of links between the Level of Development of particular project in Building Information Modeling environment and the projects of certain stages of project documentation within the existing Czech Republic’s Legislation. This research article uses the experiences from the initiative of active working group „WG#03: BIM & Realization“, which is the part of the Czech BIM Council, especially the document called “Draft of unified data structure for Building Information Modeling in the Czech Republic”. The findings of this paper are in the defining specific Level of Development of relative parameters, mentioned in this document, connected to the specific level of information and details requested by the Czech Republic’s Legislation. These findings could be used as an underlay to create document called “Level of Development draft assignment to the individual stages of project documentation in the Czech Republic”. The Level of Development is the most useful way of the information visualization, which leads to the most effortless way of exact stated implementation of Building Information Modeling into the practice of designing structures and buildings in the Czech Republic. The Implementation of using Building Information Modeling technology in designing structures and buildings will lead to the enhanced quality of the project documentation and generally to more effective cost savings during whole life cycle of buildings. Moreover, the all over using of the BIM technology in the Czech Republic will be very useful in the Facility Management area, especially in the facility management and maintenance of state buildings.

  12. Anti-logic or common sense that can hinder machine’s energy performance: Energy and comfort control models based on artificial intelligence responding to abnormal indoor environments

    International Nuclear Information System (INIS)

    Ahn, Jonghoon; Cho, Soolyeon

    2017-01-01

    Highlights: •Integrated energy control model improves thermal comfort and mitigates an increase of energy consumption. •Communication between heating and cooling, thermal comfort, and decision making models optimizes energy supply. •PMV model effectively rectifies set-point temperature to reduce thermal dissatisfaction in various conditions. •Five-step decision making model properly responds to abnormal situations derived from human anti-logic or common sense. •Integrated model can be extended for managing risks caused by fire or disasters. -- Abstract: In spite of the remarkable development of technology, most studies for building energy controls to evaluate or estimate the energy performance have not accurately reflected actual building’s energy consumption patterns. For this issue, several techniques, such as simulation and calibration, comprehensive survey system, smart metering, and commissioning, have been attempted. However, in most studies, some factors in thermal systems derived from occupant behavior were perceived as fixed objects, and the factors were converted into simple numbers as parts of inputs into simulation templates. There was lack of studies on considerations that unpredictable responses derived from human anti-logic or common sense could deteriorate energy efficiency in theoretical analyses even though the systems were properly operated. This research proposes integrated energy supply models based on artificial intelligence responding to anti-logic or common sense that can reduce machine’s energy saving effects. By use of design scenarios assuming some unusual situations, a decision making model determines the extent to which the cause of the abnormal situations are associated with the occupant behavior. After the five-step phases in the decision making model, the actual outputs of the energy supply model for the buildings are determined, and the reciprocal communication between the thermal and decision making models mitigates

  13. Responding to Changes in Building Legislation. Updating Training for the Building Regulations 1985 and Supporting Documents.

    Science.gov (United States)

    Harris, Robert; Phillips, Alan

    A project sought to develop a means of updating and retraining those required to comply with Britain's 1985 Building Regulations, which are substantially different from the previous ones in regard to procedures and technical content. The training needs analysis conducted indicated that the new training should be flexible and use practical and…

  14. Level 3 baseline risk evaluation for Building 3506 at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    Golden, K.M.; Robers, S.K.; Cretella, F.M.

    1994-12-01

    This report presents the results of the Level 3 Baseline Risk Evaluation (BRE) performed on Building 3506 located at the Oak Ridge National Laboratory (ORNL). This BRE is intended to provide an analysis of the potential for adverse health effects (current or future) posed by contaminants at the facility. The decision was made to conduct a Level 3 (least rigorous) BRE because only residual contamination exists in the building. Future plans for the facility (demolition) also preclude a rigorous analysis. Site characterization activities for Building 3506 were conducted in fall of 1993. Concrete core samples were taken from the floors and walls of both the cell and the east gallery. These cores were analyzed for radionuclides and organic and inorganic chemicals. Smear samples and direct radiation measurements were also collected. Sediment exists on the floor of the cell and was also analyzed. To adequately characterize the risks posed by the facility, receptors for both current and potential future land uses were evaluated. For the current land use conditions, two receptors were evaluated. The first receptor is a hypothetical maintenance worker who spends 250 days (8 hours/day) for 25 years working in the facility. The remaining receptor evaluated is a hypothetical S and M worker who spends 2 days (8 hours/day) per year for 25 years working within the facility. This particular receptor best exemplifies the current worker scenario for the facility. The two current exposure scenarios and parameters of exposure (e.g., inhalation and ingestion rates) have been developed to provide a conservative (i.e. health protective) estimate of potential exposure

  15. Level 3 baseline risk evaluation for Building 3506 at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    Golden, K.M.; Robers, S.K.; Cretella, F.M.

    1994-12-01

    This report presents the results of the Level 3 Baseline Risk Evaluation (BRE) performed on Building 3506 located at the Oak Ridge National Laboratory (ORNL). This BRE is intended to provide an analysis of the potential for adverse health effects (current or future) posed by contaminants at the facility. The decision was made to conduct a Level 3 (least rigorous) BRE because only residual contamination exists in the building. Future plans for the facility (demolition) also preclude a rigorous analysis. Site characterization activities for Building 3506 were conducted in fall of 1993. Concrete core samples were taken from the floors and walls of both the cell and the east gallery. These cores were analyzed for radionuclides and organic and inorganic chemicals. Smear samples and direct radiation measurements were also collected. Sediment exists on the floor of the cell and was also analyzed. To adequately characterize the risks posed by the facility, receptors for both current and potential future land uses were evaluated. For the current land use conditions, two receptors were evaluated. The first receptor is a hypothetical maintenance worker who spends 250 days (8 hours/day) for 25 years working in the facility. The remaining receptor evaluated is a hypothetical S and M worker who spends 2 days (8 hours/day) per year for 25 years working within the facility. This particular receptor best exemplifies the current worker scenario for the facility. The two current exposure scenarios and parameters of exposure (e.g., inhalation and ingestion rates) have been developed to provide a conservative (i.e. health protective) estimate of potential exposure.

  16. Dishonest responding or true virtue?

    DEFF Research Database (Denmark)

    Zettler, Ingo; Hilbig, Benjamin E.; Moshagen, Morten

    2015-01-01

    but troubling proposition that high scores in impression management scales actually reflect honesty rather than dishonest responding. In line with findings indicating that respondents answer to personality questionnaires rather accurately in typical low demand situations, we herein suggest that high impression...... management scores indeed reflect true virtues rather than dishonesty under such conditions. We found support for this idea by replicating previous correlations between impression management scores and virtue-related basic personality traits (including honesty-humility), and additionally provided conclusive...

  17. Reducing failures rate within the project documentation using Building Information Modelling, especially Level of Development

    Directory of Open Access Journals (Sweden)

    Prušková Kristýna

    2018-01-01

    Full Text Available Paper´s focus is on differences between traditional modelling in 2D software and modelling within the BIM technology. Research uncovers failures connected to the traditional way of designing and construction of project documentation. There are revealed and shown mismatches within the project documentation. Solution within the Building information modelling Technology is outlined. As a reference, there is used experience with design of specific building in both ways of construction of project documentation: in the way of traditional modelling and in the way when using BIM technology, especially using Level of Development. Output of this paper is pointing to benefits of using advanced technology in building design, thus Building Information Modelling, especially Level of Development, which leads to reducing failures rate within the project documentation.

  18. Study of Customer Satisfaction with Living Conditions in New Apartment Buildings

    OpenAIRE

    Lepkova Natalija; Butkiene Egle; Bełej Miroslaw

    2016-01-01

    The article aims to analyze the Lithuanian housing market and to look into the satisfaction of people with living conditions in new apartment buildings on this market. The article presents the concept of customer satisfaction in construction and the criteria that define the quality of dwellings; the benefits, consequences, merits and demerits of the assessment of customer satisfaction are also named. A survey of customer satisfaction helped to evaluate the quality of dwellings according to th...

  19. Nationwide Analysis of U.S. Commercial Building Solar Photovoltaic (PV) Breakeven Conditions

    Energy Technology Data Exchange (ETDEWEB)

    Davidson, Carolyn [National Renewable Energy Lab. (NREL), Golden, CO (United States); Gagnon, Pieter [National Renewable Energy Lab. (NREL), Golden, CO (United States); Denholm, Paul [National Renewable Energy Lab. (NREL), Golden, CO (United States); Margolis, Robert [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-10-01

    The commercial sector offers strong potential for solar photovoltaics (PV) owing to abundant available roof space suitable for PV and the opportunity to offset the sector's substantial retail electricity purchases. This report evaluated the breakeven price of PV for 15 different building types and various financing options by calculating electricity savings based on detailed rate structures for most U.S. utility territories (representing approximately two thirds of U.S. commercial customers). We find that at current capital costs, an estimated 1/3 of U.S. commercial customers break even in the cash scenario and approximately 2/3 break even in the loan scenario. Variation in retail rates is a stronger driver of breakeven prices than is variation in building load or solar generation profiles. At the building level, variation in the average breakeven price is largely driven by the ability for a PV system to reduce demand charges.

  20. Creating a three level building classification using topographic and address-based data for Manchester

    Science.gov (United States)

    Hussain, M.; Chen, D.

    2014-11-01

    Buildings, the basic unit of an urban landscape, host most of its socio-economic activities and play an important role in the creation of urban land-use patterns. The spatial arrangement of different building types creates varied urban land-use clusters which can provide an insight to understand the relationships between social, economic, and living spaces. The classification of such urban clusters can help in policy-making and resource management. In many countries including the UK no national-level cadastral database containing information on individual building types exists in public domain. In this paper, we present a framework for inferring functional types of buildings based on the analysis of their form (e.g. geometrical properties, such as area and perimeter, layout) and spatial relationship from large topographic and address-based GIS database. Machine learning algorithms along with exploratory spatial analysis techniques are used to create the classification rules. The classification is extended to two further levels based on the functions (use) of buildings derived from address-based data. The developed methodology was applied to the Manchester metropolitan area using the Ordnance Survey's MasterMap®, a large-scale topographic and address-based data available for the UK.

  1. "On-off-on" switchable sensor: a fluorescent spiropyran responds to extreme pH conditions and its bioimaging applications.

    Science.gov (United States)

    Wan, Shulin; Zheng, Yang; Shen, Jie; Yang, Wantai; Yin, Meizhen

    2014-11-26

    A novel spiropyran that responds to both extreme acid and extreme alkali and has an "on-off-on" switch is reported. Benzoic acid at the indole N-position and carboxyl group at the indole 6-position contribute to the extreme acid response. The ionizations of carboxyl and phenolic hydroxyl groups cause the extreme alkali response. Moreover, the fluorescent imaging in bacterial cells under extreme pH conditions supports the mechanism of pH response.

  2. The Future of Air Conditioning for Buildings - Executive Summary

    Energy Technology Data Exchange (ETDEWEB)

    Goetzler, William [Navigant Consulting Inc., Burlington, MA (United States); Guernsey, Matt [Navigant Consulting Inc., Burlington, MA (United States); Young, J. [Navigant Consulting Inc., Burlington, MA (United States); Fuhrman, J. [Navigant Consulting Inc., Burlington, MA (United States); Abdelaziz, Omar [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-07-01

    The Building Technologies Office (BTO), within the U.S. Department of Energy’s (DOE) Office of Energy Efficiency and Renewable Energy, works with researchers and industry to develop and deploy technologies that can substantially reduce energy consumption and greenhouse gas (GHG) emissions in residential and commercial buildings. Air conditioning (A/C) systems in buildings contribute to GHG emissions both directly through refrigerant emissions, as well as indirectly through fossil fuel combustion for power generation. BTO promotes pre-competitive research and development (R&D) on next-generation HVAC technologies that support the phase down of hydrofluorocarbon (HFC) production and consumption, as well as cost-effective energy efficiency improvements. Over the past several decades, product costs and lifecycle cooling costs have declined substantially in many global markets due to improved, higher-volume manufacturing and higher energy efficiency driven by R&D investments and efficiency policies including minimum efficiency standards and labeling programs.1 This report characterizes the current landscape and trends in the global A/C market, including discussion of both direct and indirect climate impacts, and potential global warming impacts from growing global A/C usage. The report also documents solutions that can help achieve international goals for energy efficiency and GHG emissions reductions. The solutions include pathways related to low-global warming potential2 (GWP) refrigerants, energy efficiency innovations, long-term R&D initiatives, and regulatory actions. DOE provides, with this report, a fact-based vision for the future of A/C use around the world. DOE intends for this vision to reflect a broad and balanced aggregation of perspectives. DOE brings together this content in an effort to support dialogue within the international community and help keep key facts and objectives at the forefront among the many important discussions.

  3. Numerical model for stack gas diffusion in terrain with buildings. Variations in air flow and gas concentration with additional building near stack

    International Nuclear Information System (INIS)

    Sada, Koichi; Michioka, Takenobu; Ichikawa, Yoichi; Komiyama, Sumito; Numata, Kunio

    2009-01-01

    A numerical simulation method for predicting atmospheric flow and stack gas diffusion using a calculation domain of several km around a stack under complex terrain conditions containing buildings has been developed. The turbulence closure technique using a modified k-ε-type model without a hydrostatic approximation was used for flow calculation, and some of the calculation grids near the ground were treated as buildings using a terrain-following coordinate system. Stack gas diffusion was predicted using the Lagrangian particle model, that is, the stack gas was represented by trajectories of released particles. The developed numerical model was applied to a virtual terrain and building conditions in this study prior to the applications of a numerical model for real terrain and building conditions. The height of the additional building (H a ), located about 200 m leeward from the stack, was varied (i.e., H a =0, 20, 30 and 50 m), and its effects on airflow and the concentration of stack gas at a released height of 75 m were calculated. Furthermore, effective stack height, which was used in the safety analysis of atmospheric diffusion for nuclear facilities in Japan, was evaluated from the calculated ground-level concentration of stack gas. The cavity region behind the additional building was calculated, and turbulence near the cavity was observed to decrease when the additional building was present. According to these flow variations with the additional building, tracer gas tended to diffuse to the ground surface rapidly with the additional building at the leeward position of the cavity, and the ground-level stack gas concentration along the plume axis also increased with the height of the additional building. However, the variations in effective stack height with the height of the additional building were relatively small and ranged within several m in this study. (author)

  4. Calculation of Environmental Conditions in NEK Intermediate Building Following HELB

    International Nuclear Information System (INIS)

    Grgic, D.; Spalj, S.; Basic, I.

    1998-01-01

    The purpose of Equipment Qualification (EQ) in nuclear power plants is to ensure the capability of safety related equipment to perform its function on demand under postulated service conditions, including harsh accident environment (e.g. Loss of Coolant Accident - LOCA, High Energy Line Break - HELB). The determination of the EQ conditions and zones is one of the basic steps in the frame of the overall EQ project. The EQ parameters (temperature, pressure, relative humidity, chemical spray, submergence, radiation) should be defined for all locations of the plant containing equipment important to safety. This paper presents the calculation of thermohydraulic environmental parameters (pressure and temperature) inside Intermediate Building (IB) of Krsko NPP after the postulated HELB. The RELAP5/mod2 computer code was used for the determination of HELB mass and energy release and computer code GOTHIC was used to calculate pressure and temperature profiles inside NPP Krsko IB. (author)

  5. Toward a virtual building laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Klems, J.H.; Finlayson, E.U.; Olsen, T.H.; Banks, D.W.; Pallis, J.M.

    1999-03-01

    In order to achieve in a timely manner the large energy and dollar savings technically possible through improvements in building energy efficiency, it will be necessary to solve the problem of design failure risk. The most economical method of doing this would be to learn to calculate building performance with sufficient detail, accuracy and reliability to avoid design failure. Existing building simulation models (BSM) are a large step in this direction, but are still not capable of this level of modeling. Developments in computational fluid dynamics (CFD) techniques now allow one to construct a road map from present BSM's to a complete building physical model. The most useful first step is a building interior model (BIM) that would allow prediction of local conditions affecting occupant health and comfort. To provide reliable prediction a BIM must incorporate the correct physical boundary conditions on a building interior. Doing so raises a number of specific technical problems and research questions. The solution of these within a context useful for building research and design is not likely to result from other research on CFD, which is directed toward the solution of different types of problems. A six-step plan for incorporating the correct boundary conditions within the context of the model problem of a large atrium has been outlined. A promising strategy for constructing a BIM is the overset grid technique for representing a building space in a CFD calculation. This technique promises to adapt well to building design and allows a step-by-step approach. A state-of-the-art CFD computer code using this technique has been adapted to the problem and can form the departure point for this research.

  6. Building-related symptoms and inflammatory potency of dust from office buildings

    DEFF Research Database (Denmark)

    Allermann, L; Pejtersen, J; Gunnarsen, L

    2007-01-01

    UNLABELLED: The aim was to investigate the association between building-related symptoms (BRS) in office buildings and the inflammatory potency of dust (PD). Furthermore, the association between dust potency and various building characteristics was investigated. Occupants of 22 office buildings...... received a retrospective questionnaire about BRS (2301 respondents). Dust was collected from groups of offices and building characteristics were recorded. The potency of a dust sample to induce interleukin-8 (IL-8) secretion from the lung epithelial cell line A549 was measured as the slope of the initial...... linear part of the concentration-response curve. Symptoms of the central nervous system (CNS) were associated with the potency of surface dust (OR = 1.4). This association may be due to an association between an index of CNS symptoms and dust potency in offices of 1-6 occupants (OR = 1.5). No single...

  7. Energy edge post-occupancy evaluation project: the Hollywood Office Building, Portland, Oregon

    Energy Technology Data Exchange (ETDEWEB)

    1990-06-01

    The Hollywood Office Park Building Survey for the Energy Post- Occupancy Project was administered to nine building occupants. The nine respondents answered the questions which rated building features in the areas of (1) thermal factors; (2) air quality; (3) lighting; (4) acoustics; and, (5) overall workspace satisfaction. In addition to rating these ambient environmental features, these respondents also rated their satisfaction of various functional and aesthetic features and specific kinds of workspaces. Data was also collected on heath characteristics and occupational demographics of the respondents. No analysis is made of the survey findings which are reported in graphic format. 15 figs. (BN)

  8. The At Issue Maturity of Corporate Bonds: The Influence of Credit Rating, Security Level, Duration and Macreoconomic Conditions

    OpenAIRE

    Geetajali Bali; Frank Skinner

    2003-01-01

    We examine the determinants of the at issue time to maturity of corporate bonds. We find evidence that corporations partly determine the at issue maturity of bonds by responding to economic conditions. They also appear to immunize by matching the maturity of assets with the at issue maturity of bonds regardless of credit quality. Finally, we find evidence that the security level (our proxy for the recovery rate) is inversely related to the at issue time to maturity. This suggests that lenders...

  9. 77 FR 49345 - Preventing and Responding to Violence Against Women and Girls Globally

    Science.gov (United States)

    2012-08-16

    ... effectively prevent and respond to gender- based violence globally. (b) Under the leadership of my... that women's empowerment is critical to building stable, democratic societies; to supporting open and...

  10. Condition Assessment of the Timber Structures of a Century-Old Industrial Building Using a Nondestructive Inspection Procedure

    Science.gov (United States)

    Xiping Wang; Marko Teder; James Wacker

    2013-01-01

    This paper reports an in situ inspection project conducted on heavy timber structures of a century-old industrial building at a paper manufacturing facility. A nondestructive inspection procedure was employed to evaluate the true condition of the heavy timbers that serve as the main framing structure of the building. The on-site investigation involved monitoring of the...

  11. Insulin resistance in clomiphene responders and non-responders with polycystic ovarian disease and therapeutic effects of metformin.

    Science.gov (United States)

    Parsanezhad, M E; Alborzi, S; Zarei, A; Dehbashi, S; Omrani, G

    2001-10-01

    To evaluate the clinical features, endocrine and metabolic profiles in clomiphene (CC) responders and non-responders with polycystic ovarian disease (PCOD), and to examine the effects of metformin (MTF) on the above parameters of CC resistance. A prospective clinical trial was undertaken at the infertility division of a university teaching hospital. Forty-one CC responders were selected and their hormonal and clinical features were determined. Forty-one CC-resistant PCOD women were also selected and clinical features; metabolic and hormonal profiles before and after treatment with MTF 1500 mg/day for 6-8 weeks were evaluated. Women who failed to conceive were treated by CC while continuing to take MTF. CC responders had higher insulin levels while non-responders were hyperinsulinemic. Menstrual irregularities improved in 30%. Mean+/-S.D. area under curve of insulin decreased from 297.58+/-191.33 to 206+/-0.1 mIU/ml per min (P=0.005). Only 39.39% ovulated and 24.24% conceived. PCOD is associated with insulin resistance (IR) particularly in CC-resistant women. Insulin resistance and androgen levels are significantly higher in obese patients. MTF therapy improved hyperandrogenemia, IR, and pregnancy rate.

  12. The CBM first-level event selector, timeslice building and availability studies

    Energy Technology Data Exchange (ETDEWEB)

    Hartmann, Helvi; Cuveland, Jan de; Lindenstruth, Volker [Frankfurt Institute for Advanced Studies, Goethe University, Frankfurt (Germany); Collaboration: CBM-Collaboration

    2016-07-01

    The Compressed Baryonic Matter (CBM) experiment is a fixed target high energy physics experiment collecting all produced data - no triggers are involved. This causes a very high data rate of 1 TByte/s. The First-level Event Selector (FLES) denotes a high performance computer cluster that will process all data and performs a full online event reconstruction. For this purpose the raw detector data is accessed in time intervals referred to as Timeslices. In the process of Timeslice building data from all input links are distributed via a high-performance Infiniband network to the compute nodes. In order to ensure that the FLES is available the whole time while the detectors are running fault tolerance is inevitable. The questions is how often are incidents going to occur (Mean Time between Failure MTBF) and how long will they pause Timeslice building and hence physics analysis (Mean Time to Repair MTTR). These two factors make up the availability of the FLES. I present a detailed analysis of possible sources of errors and their influence on the availability. Furthermore, I discuss the development of Timeslice building on the basis of MPI with respect to the availability of the FLES. I compare this approach to a low-level native Infiniband Verbs implementation combined with a socket-based error handling system.

  13. Childhood conditions influence adult progesterone levels.

    Directory of Open Access Journals (Sweden)

    Alejandra Núñez-de la Mora

    2007-05-01

    Full Text Available Average profiles of salivary progesterone in women vary significantly at the inter- and intrapopulation level as a function of age and acute energetic conditions related to energy intake, energy expenditure, or a combination of both. In addition to acute stressors, baseline progesterone levels differ among populations. The causes of such chronic differences are not well understood, but it has been hypothesised that they may result from varying tempos of growth and maturation and, by implication, from diverse environmental conditions encountered during childhood and adolescence.To test this hypothesis, we conducted a migrant study among first- and second-generation Bangladeshi women aged 19-39 who migrated to London, UK at different points in the life-course, women still resident in Bangladesh, and women of European descent living in neighbourhoods similar to those of the migrants in London (total n = 227. Data collected included saliva samples for radioimmunoassay of progesterone, anthropometrics, and information from questionnaires on diet, lifestyle, and health. Results from multiple linear regression, controlled for anthropometric and reproductive variables, show that women who spend their childhood in conditions of low energy expenditure, stable energy intake, good sanitation, low immune challenges, and good health care in the UK have up to 103% higher levels of salivary progesterone and an earlier maturation than women who develop in less optimal conditions in Sylhet, Bangladesh (F9,178 = 5.05, p < 0.001, standard error of the mean = 0.32; adjusted R(2 = 0.16. Our results point to the period prior to puberty as a sensitive phase when changes in environmental conditions positively impact developmental tempos such as menarcheal age (F2,81 = 3.21, p = 0.03 and patterns of ovarian function as measured using salivary progesterone (F2,81 = 3.14, p = 0.04.This research demonstrates that human females use an extended period of the life cycle prior

  14. Infrasonic waves and air-conditioning

    Energy Technology Data Exchange (ETDEWEB)

    Hoenmann, W.

    1986-08-01

    This article is a critical investigation of the recently-suggested possibility that the infrasound generated by an air conditioning system (up to 2o kHz) may adversely affect the well-being of human beings. After an introductory explanation of the infrasonic wave band and the dependency of the sound pressure level on the frequency for decibel values of 20 to 100 (diagram), the relevant results of studies by various experts are quoted. It became apparent that the influence of the inaudible infrasound has been greatly overestimated, whereas audibility was underestimated. Inaudible infrasound was shown to be completely harmless. A number of frequency variation analysis diagrams of various residences (old building, new building) with audibility thresholds marked in. The measurement results discussed in more detail indicate that it is possible not to raise the basic noise level of an air conditioning system in the low-frequency range. Therein lies the actual acoustic chance for air conditioning: In an air-conditioned building, there is no need to ventilate by means of open windows, thereby letting in traffic noise, the nuisance value of which is beyond dispute. (HWJ).

  15. Growth, chamber building rate and reproduction time of Palaeonummulites venosus under natural conditions.

    Science.gov (United States)

    Kinoshita, Shunichi; Eder, Wolfgang; Wöger, Julia; Hohenegger, Johann; Briguglio, Antonino

    2017-04-01

    Investigations on Palaeonummulites venosus using the natural laboratory approach for determining chamber building rate, test diameter increase rate, reproduction time and longevity is based on the decomposition of monthly obtained frequency distributions based on chamber number and test diameter into normal-distributed components. The shift of the component parameters 'mean' and 'standard deviation' during the investigation period of 15 months was used to calculate Michaelis-Menten functions applied to estimate the averaged chamber building rate and diameter increase rate under natural conditions. The individual dates of birth were estimated using the inverse averaged chamber building rate and the inverse diameter increase rate fitted by the individual chamber number or the individual test diameter at the sampling date. Distributions of frequencies and densities (i.e. frequency divided by sediment weight) based on chamber building rate and diameter increase rate resulted both in a continuous reproduction through the year with two peaks, the stronger in May /June determined as the beginning of the summer generation (generation1) and the weaker in November determined as the beginning of the winter generation (generation 2). This reproduction scheme explains the existence of small and large specimens in the same sample. Longevity, calculated as the maximum difference in days between the individual's birth date and the sampling date seems to be round about one year, obtained by both estimations based on the chamber building rate and the diameter increase rate.

  16. Evaluation of noise level in architecture department building in University of Sumatera Utara

    Science.gov (United States)

    Amran, Novrial; Damanik, Novita Hillary Christy

    2018-03-01

    Noise is one the comfort factors that need to be noticed, particularly in an educational environment. Hearing a high noise in a period can affect students’ learning performance. The aims of this study were to know the noise level and get an appropriate design to reduce noise in Architecture Department building in the University of Sumatera Utara, considering that architecture students often spend most of their time inside the room. The measurement was conducted in four rooms for two days each from 09:00 – 12:00 and from 13:00 – 16:00 by using Sound Level Meter that placed near the noise source of the room. The result indicated that the average of noise level exceeded the 55 dB(A) so it still needs the appropriate design to reduce the noise that occurs in the building.

  17. INDUCON building concept; INDUCON-rakennuskonsepti

    Energy Technology Data Exchange (ETDEWEB)

    Sarja, A.; Laine, J.; Pulakka, S.; Saari, M. [VTT Building and Transport, Espoo (Finland)

    2003-08-01

    The new and stronger requirements: lifetime economy, functionality in use and in changes of use, technical lifetime performance, energy efficiency, healthy, safety, ecology and local culture, are serving a challenge for the building technology. Additionally the pressure towards decreasing the construction costs with the increase of productivity of the work and capital is increased. The objective of this research work has been to respond the challenges described above with creating alternative building concepts, which could allow production of individually designed apartment and office buildings, including methodology and methods to optimise the building concepts and individual buildings in relation to the lifetime quality. Building concept is a repeatable and documented way of design and construction, which can result in individual buildings with an optimised and high lifetime quality. Lifetime quality is the capability of a building to fulfil the requirements of the users, owners and society during entire design period of the building. The INDUCON building concept is focused on the following issues: Classified and optimised lifetime quality (incl. the viewpoints of functionality, performance, economy, ecology and culture), and the realisation of industrial production on an advanced level (incl. new models of building design and construction, simplification of building systems and products, decrease of the number of parts of buildings, improvement of finishing of the prefabricated components and modules, and improving the interaction and compatibility of structures and building service systems). As a result are presented: systematised and classified definitions of performance properties of buildings; corresponding specifications of building systems, modules and components; design principles, process descriptions; examples (incl. Routings of technical building services, specification and classification of the health and comfort properties of indoor air, calculations

  18. Indoor radon levels in Columbus and Franklin county, Ohio residences, commercial buildings, and schools

    International Nuclear Information System (INIS)

    Grafton, H.E.

    1990-01-01

    In this paper data is presented for 2 residential radon surveys, one survey of city-owned buildings, and survey of Columbus Public Schools. The first residential survey used volunteer participants and employed a 48 hour activated carbon measurement: 4425 measurements in the data. The second survey consisted of 120 randomly selected residences in which alpha track detectors were placed for from 60 to 120 days. A survey of 52 city-owned buildings in which screening measurements were obtained using activated carbon, alpha track, and E-PERM radon detectors is included in the data. Also a survey of 25 Columbus Public Schools in which E-PERM radon monitors were used to obtain measurements is detailed in the data. More than 72% of the volunteer survey residences showed screening measurements of 4.0 pCi/L or greater while the random survey revealed 92% of the residences with radon levels of 4.0 pCi/L or higher. Schools tested in the survey also showed elevated radon levels with 20% of the tested structures with an average radon level of 4.0 pCi/L. Work is still in progress on city-owned buildings and Columbus Schools. The authors conclude that any owner or lessor of occupied buildings in Franklin County, Ohio should perform screening measurements and should be prepared to also perform follow-up measurements

  19. Species-specific response-topography of chickens' and pigeons' water-induced autoshaped responding.

    Science.gov (United States)

    Ploog, Bertram O

    2014-07-01

    Four pigeons and eight chickens received autoshaping training where a keylight (conditioned stimulus) signaled response-independent deliveries of water (unconditioned stimulus). Pigeons drink while keeping their beaks submerged in water and moving their beaks to create suction ("mumbling"), whereas chickens drink by trapping a small amount of water in their mouths and then lifting their heads so the water trickles down. This experiment tested whether these and other species-specific differences in drinking and related behaviors of pigeons and chickens would be reflected in the form of conditioned (autoshaped) responding. Touchscreens and videotapes were used for data recording. Results showed that chickens moved their heads more than pigeons when drinking (unconditioned response). The birds also differed in conditioned responding in the presence of the keylight: Pigeons produced more keyswitch closures and mumbled at the keylight more than chickens whereas chickens scratched more than pigeons. In conclusion, with this unique comparative method that employed identical contingencies and comparable deprivation levels, species-specific differences in unconditioned responses and, more importantly, differences in their corresponding conditioned responses were observed. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Building-related symptoms and inflammatory potency of dust from office buildings

    DEFF Research Database (Denmark)

    Allermann, Leila; Pejtersen, Jan; Gunnarsen, Lars Bo

    2007-01-01

    Abstract The aim was to investigate the association between building-related symptoms (BRS) in office buildings and the inflammatory potency of dust (PD). Furthermore, the association between dust potency and various building characteristics was investigated. Occupants of 22 office buildings...... received a retrospective questionnaire about BRS (2301 respondents). Dust was collected from groups of offices and building characteristics were recorded. The potency of a dust sample to induce interleukin-8 (IL-8) secretion from the lung epithelial cell line A549 was measured as the slope of the initial...... linear part of the concentration- response curve. Symptoms of the central nervous system (CNS) were associated with the potency of surface dust (OR ¼ 1.4). This association may be due to an association between an index of CNS symptoms and dust potency in offices of 1-6 occupants (OR ¼ 1.5). No single...

  1. Serum PCSK9 Levels Distinguish Individuals Who Do Not Respond to High-Dose Statin Therapy with the Expected Reduction in LDL-C

    Directory of Open Access Journals (Sweden)

    Beth A. Taylor

    2014-01-01

    Full Text Available The purpose of the present report was to examine whether proprotein convertase subtilisin/kexin type 9 (PCSK9 levels differ in individuals who do not exhibit expected reductions in low density lipoprotein cholesterol (LDL-C with statin therapy. Eighteen nonresponder subjects treated with 80 mg atorvastatin treatment for 6 months without substantial reductions in LDL-C (ΔLDL-C: 2.6 ± 11.4% were compared to age- and gender-matched atorvastatin responders (ΔLDL-C: 50.7 ± 8.5% and placebo-treated subjects (ΔLDL-C: 9.9 ± 21.5%. Free PCSK9 was marginally higher in nonresponders at baseline (P=0.07 and significantly higher in atorvastatin responders after 6 months of treatment (P=0.04. The change in free PCSK9 over 6 months with statin treatment was higher (P<0.01 in atorvastatin responders (134.2 ± 131.5 ng/mL post- versus prestudy than in either the nonresponders (39.9 ± 87.8 ng/mL or placebo subjects (27.8 ± 97.6 ng/mL. Drug compliance was not lower in the nonresponders as assessed by pill counts and poststudy plasma atorvastatin levels. Serum PCSK9 levels, both at baseline and in response to statin therapy, may differentiate individuals who do versus those who do not respond to statin treatment.

  2. Return momentum effect on reactor coolant water level distribution during mid-loop conditions

    International Nuclear Information System (INIS)

    Seo, Jae Kwang; Yang, Jae Young; Park, Goon Cherl

    2001-01-01

    An accurate prediction of the Reactor Coolant System( RCS) water level is of importance in the determination of the allowable operating range to ensure safety during mid-loop operations. However, complex hydrualic phenomena induced by the Shutdown Cooling System (SCS) return momentum causes different water levels from those in the loop where the water level indicators are located. This was apparently observed at the pre-core cold hydro test of the Younggwang Nuclear Unit 3 (YGN 3) in Korea. In this study, in order to analytically understand the effect of the SCS return momentum on the RCS water level distribution, a model using a one-dimensional momentum and energy conservation for cylindrical channel, hydraulic jump in operating cold leg, water level build-up at the Reactor Vessel (RV) inlet nozzle, Bernoulli constant in downcomer region, and total water volume conservation has been developed. The model predicts the RCS water levels at various RCS locations during the mid-loop conditions and the calculation results were compared with the test data. The analysis shows that the hydraulic jump in the operating cold legs, in conjuction with the pressure drop throughout the RCS, is the main cause creating the water level differences at various RCS locations. The prediction results provide good explanations for the test data and show the significant effect of the SCS return momentum on the RCS water levels

  3. WASTE HANDLING BUILDING FIRE PROTECTION SYSTEM DESCRIPTION DOCUMENT

    Energy Technology Data Exchange (ETDEWEB)

    J. D. Bigbee

    2000-06-21

    The Waste Handling Building Fire Protection System provides the capability to detect, control, and extinguish fires and/or mitigate explosions throughout the Waste Handling Building (WHB). Fire protection includes appropriate water-based and non-water-based suppression, as appropriate, and includes the distribution and delivery systems for the fire suppression agents. The Waste Handling Building Fire Protection System includes fire or explosion detection panel(s) controlling various detectors, system actuation, annunciators, equipment controls, and signal outputs. The system interfaces with the Waste Handling Building System for mounting of fire protection equipment and components, location of fire suppression equipment, suppression agent runoff, and locating fire rated barriers. The system interfaces with the Waste Handling Building System for adequate drainage and removal capabilities of liquid runoff resulting from fire protection discharges. The system interfaces with the Waste Handling Building Electrical Distribution System for power to operate, and with the Site Fire Protection System for fire protection water supply to automatic sprinklers, standpipes, and hose stations. The system interfaces with the Site Fire Protection System for fire signal transmission outside the WHB as needed to respond to a fire emergency, and with the Waste Handling Building Ventilation System to detect smoke and fire in specific areas, to protect building high-efficiency particulate air (HEPA) filters, and to control portions of the Waste Handling Building Ventilation System for smoke management and manual override capability. The system interfaces with the Monitored Geologic Repository (MGR) Operations Monitoring and Control System for annunciation, and condition status.

  4. WASTE HANDLING BUILDING FIRE PROTECTION SYSTEM DESCRIPTION DOCUMENT

    International Nuclear Information System (INIS)

    J. D. Bigbee

    2000-01-01

    The Waste Handling Building Fire Protection System provides the capability to detect, control, and extinguish fires and/or mitigate explosions throughout the Waste Handling Building (WHB). Fire protection includes appropriate water-based and non-water-based suppression, as appropriate, and includes the distribution and delivery systems for the fire suppression agents. The Waste Handling Building Fire Protection System includes fire or explosion detection panel(s) controlling various detectors, system actuation, annunciators, equipment controls, and signal outputs. The system interfaces with the Waste Handling Building System for mounting of fire protection equipment and components, location of fire suppression equipment, suppression agent runoff, and locating fire rated barriers. The system interfaces with the Waste Handling Building System for adequate drainage and removal capabilities of liquid runoff resulting from fire protection discharges. The system interfaces with the Waste Handling Building Electrical Distribution System for power to operate, and with the Site Fire Protection System for fire protection water supply to automatic sprinklers, standpipes, and hose stations. The system interfaces with the Site Fire Protection System for fire signal transmission outside the WHB as needed to respond to a fire emergency, and with the Waste Handling Building Ventilation System to detect smoke and fire in specific areas, to protect building high-efficiency particulate air (HEPA) filters, and to control portions of the Waste Handling Building Ventilation System for smoke management and manual override capability. The system interfaces with the Monitored Geologic Repository (MGR) Operations Monitoring and Control System for annunciation, and condition status

  5. Demand Response Technology Readiness Levels for Energy Management in Blocks of Buildings

    Directory of Open Access Journals (Sweden)

    Tracey Crosbie

    2018-01-01

    Full Text Available Fossil fuels deliver most of the flexibility in contemporary electricity systems. The pressing need to reduce CO2 emissions requires new methods to provide this flexibility. Demand response (DR offers consumers a significant role in the delivery of flexibility by reducing or shifting their electricity usage during periods of stress or constraint. Blocks of buildings offer more flexibility in the timing and use of energy than single buildings, however, and a lack of relevant scalable ICT tools hampers DR in blocks of buildings. To ameliorate this problem, a current innovation project called “Demand Response in Blocks of Buildings” (DR-BoB: www.dr-bob.eu has integrated existing technologies into a scalable cloud-based solution for DR in blocks of buildings. The degree to which the DR-BoB energy management solution can increase the ability of any given site to participate in DR is dependent upon its current energy systems, i.e., the energy metering, the telemetry and control technologies in building management systems, and the existence/capacity of local power generation and storage plants. To encourage the owners and managers of blocks of buildings to participate in DR, a method of assessing and validating the technological readiness to participate in DR energy management solutions at any given site is required. This paper describes the DR-BoB energy management solution and outlines what we have called the demand response technology readiness levels (DRTRLs for the implementation of such a solution in blocks of buildings.

  6. Determination of radioactivity levels from some Egyptian building materials

    International Nuclear Information System (INIS)

    Abd EL Sattar, M.; Morsy, A.A.

    2007-01-01

    Our world is radioactive and has been, since it was created. Over 60 radionuclides (radioactive elements) can be found in nature. Radon is naturally occurring radioactive gas, that is produced by the radioactive decay of radium. Breathing high concentration of radon can cause lung cancer. A set of experiments were carried out using Cr-39 as solid state nuclear track detectors with the optimum etching conditions, 6.25 N Na OH at 70 o C for 8 hours. The radon-222 activity in this survey was found to be in the range of 0.303 kBq/m 3 to 5.04 KBq/m 3 for different building materials in Egypt

  7. Analysis and Optimization of Building Energy Consumption

    Science.gov (United States)

    Chuah, Jun Wei

    Energy is one of the most important resources required by modern human society. In 2010, energy expenditures represented 10% of global gross domestic product (GDP). By 2035, global energy consumption is expected to increase by more than 50% from current levels. The increased pace of global energy consumption leads to significant environmental and socioeconomic issues: (i) carbon emissions, from the burning of fossil fuels for energy, contribute to global warming, and (ii) increased energy expenditures lead to reduced standard of living. Efficient use of energy, through energy conservation measures, is an important step toward mitigating these effects. Residential and commercial buildings represent a prime target for energy conservation, comprising 21% of global energy consumption and 40% of the total energy consumption in the United States. This thesis describes techniques for the analysis and optimization of building energy consumption. The thesis focuses on building retrofits and building energy simulation as key areas in building energy optimization and analysis. The thesis first discusses and evaluates building-level renewable energy generation as a solution toward building energy optimization. The thesis next describes a novel heating system, called localized heating. Under localized heating, building occupants are heated individually by directed radiant heaters, resulting in a considerably reduced heated space and significant heating energy savings. To support localized heating, a minimally-intrusive indoor occupant positioning system is described. The thesis then discusses occupant-level sensing (OLS) as the next frontier in building energy optimization. OLS captures the exact environmental conditions faced by each building occupant, using sensors that are carried by all building occupants. The information provided by OLS enables fine-grained optimization for unprecedented levels of energy efficiency and occupant comfort. The thesis also describes a retrofit

  8. Method for simulating predictive control of building systems operation in the early stages of building design

    DEFF Research Database (Denmark)

    Petersen, Steffen; Svendsen, Svend

    2011-01-01

    A method for simulating predictive control of building systems operation in the early stages of building design is presented. The method uses building simulation based on weather forecasts to predict whether there is a future heating or cooling requirement. This information enables the thermal...... control systems of the building to respond proactively to keep the operational temperature within the thermal comfort range with the minimum use of energy. The method is implemented in an existing building simulation tool designed to inform decisions in the early stages of building design through...... parametric analysis. This enables building designers to predict the performance of the method and include it as a part of the solution space. The method furthermore facilitates the task of configuring appropriate building systems control schemes in the tool, and it eliminates time consuming manual...

  9. Numerical investigations of buoyancy-driven natural ventilation in a simple atrium building and its effect on the thermal comfort conditions

    International Nuclear Information System (INIS)

    Hussain, Shafqat; Oosthuizen, Patrick H.

    2012-01-01

    In the present study use of solar-assisted buoyancy-driven natural ventilation in a simple atrium building is explored numerically with particular emphasis on the thermal comfort conditions in the building. Initially various geometric configurations of the atrium space were considered in order to investigate airflows and temperature distributions in the building using a validated computational fluid dynamics (CFD) model. The Reynolds Averaged Navier–Stokes (RANS) modelling approach with the SST-k–ω turbulence model and the Discrete Transfer Radiation Model (DTRM) was used for the investigations. The steady-state governing equations were solved using a commercial CFD solver FLUENT © . From the numerical results obtained, it was noted that an atrium space integrated with a solar chimney would be a relatively better option to be used in an atrium building. In the geometry selected, the performance of the building in response to various changes in design parameters was investigated. The produced airflows and temperature distributions were then used to evaluate indoor thermal comfort conditions in terms of the thermal comfort indices, i.e. the well-known predicted mean vote (PMV) index, its modifications especially for natural ventilation, predicted percent dissatisfied (PPD) index and Percent dissatisfied (PD) factor due to draft. It was found that the thermal conditions in the occupied areas of the building developed as a result of the use of solar-assisted buoyancy-driven ventilation for the particular values of the design parameters selected are mostly in the comfortable zone. Finally, it is demonstrated that the proposed methodology leads to reliable thermal comfort predictions, while the effect of various design variables on the performance of the building is easily recognized. - Highlights: ► Numerical investigations were carried for the use of buoyancy-driven displacement ventilation in a simple atrium building. ► Effect of various atrium

  10. CONDITIONING OF INTERMEDIATE-LEVEL WASTE AT FORSCHUNGSZENTRUM JUELICH GMBH

    International Nuclear Information System (INIS)

    Krumbach, H.

    2003-01-01

    This contribution to the group of low-level, intermediate, mixed and hazardous waste describes the conditioning of intermediate-level mixed waste (dose rate above 10 mSv/h at the surface) from Research Centre Juelich (FZJ). Conditioning of the waste by supercompaction is performed at Research Centre Karlsruhe (FZK). The waste described is radioactive waste arising from research at Juelich. This waste includes specimens and objects from irradiation experiments in the research reactors Merlin (FRJ-1) and Dido (FRJ-2) at FZJ. In principle, radioactive waste at Forschungszentrum Juelich GmbH is differentiated by the surface dose rate at the waste package. Up to a surface dose rate of 10 mSv/h, the waste is regarded as low-level. The radioactive waste described here has a surface dose rate above 10 mSv/h. Waste up to 10 mSv/h is conditioned at the Juelich site according to different conditioning methods. The intermediate-level waste can only be conditioned by supercompaction in the processing facility for intermediate-level waste from plant operation at Research Centre Karlsruhe. Research Centre Juelich also uses this waste cell to condition its intermediate-level waste from plant operation

  11. [Indoor air pollution by volatile organic compounds in large buildings: pollution levels and remaining issues after revision of the Act on Maintenance of Sanitation in Buildings in 2002].

    Science.gov (United States)

    Sakai, Kiyoshi; Kamijima, Michihiro; Shibata, Eiji; Ohno, Hiroyuki; Nakajima, Tamie

    2010-09-01

    This study aimed to clarify indoor air pollution levels of volatile organic compounds (VOCs), especially 2-ethyl-1-hexanol (2E1H) in large buildings after revising of the Act on Maintenance of Sanitation in Buildings in 2002. We measured indoor air VOC concentrations in 57 (97%) out of a total of 61 large buildings completed within one year in half of the area of Nagoya, Japan, from 2003 through 2007. Airborne concentrations of 13 carbonyl compounds were determined with diffusion samplers and high-performance liquid chromatography, and of the other 32 VOCs with diffusion samplers and gas chromatography with a mass spectrometer. Formaldehyde was detected in all samples of indoor air but the concentrations were lower than the indoor air quality standard value set in Japan (100 microg/m3). Geometric mean concentrations of the other major VOCs, namely toluene, xylene, ethylbenzene, styrene, p-dichlorobenzene and acetaldehyde were also low. 2E1H was found to be one of the predominating VOCs in indoor air of large buildings. A few rooms in a small number of buildings surveyed showed high concentrations of 2E1H, while low concentrations were observed in most rooms of those buildings as well as in other buildings. It was estimated that about 310 buildings had high indoor air pollution levels of 2E1H, with increase during the 5 years from 2003 in Japan. Indoor air pollution levels of VOCs in new large buildings are generally good, although a few rooms in a small number of buildings showed high concentrations in 2E1H, a possible causative chemical in sick building symptoms. Therefore, 2E1H needs particular attention as an important indoor air pollutant.

  12. Refurbishment and school buildings management in a smart building environment

    Science.gov (United States)

    Di Giuda, Giuseppe Martino; Villa, Valentina; Tagliabue, Lavinia Chiara; Giana, Paolo Ettore; Rinaldi, Stefano; Ciribini, Angelo Luigi Camillo

    2018-05-01

    Building Information Modelling is a methodology, which is able to take into account many data, both geometrical and non-geometrical, in order to evaluate at the actual condition of the asset. The project has the scope of evaluating the conditions of different school buildings, in order to develop a way to choose the best-tailored management solution to the owner. A further step is the management and planning of design solutions during the life cycle customized on monitored buildings' conditions. The research work focuses on providing a support decisions concerning the gap between the present building state laws and the current state of the existing buildings. The process will be developed in an expanded BIM environment, using sensors, which will give back the state of the consistency of the actual conditions to enable the buildings to adapt themselves in the best way into their specific constraints and boundaries. The results of the study are (i) a complete workflow to make decision and the possibility to shape the decision process on an objective through a scientific approach, (ii) evaluate the current state of the asset and (iii) manage maintenance in the lifespan. Further development will take in consideration all the aspects related to management of big data environment generated by a smart buildings system.

  13. Description and testing of three moisture sensors for measuring surface wetness on carbonate building stones

    Science.gov (United States)

    See, R.B.; Reddy, M.M.; Martin, R.G.

    1988-01-01

    Three moisture sensors were tested as a means for determining the surface wetness on carbonate building stones exposed to conditions that produce deposition of moisture. A relative-humidity probe, a gypsum-coated circuit grid, and a limestone-block resistor were tested as sensors for determining surface wetness. Sensors were tested under laboratory conditions of constant relative humidity and temperature and also under on-site conditions of variable relative humidity and temperature for eight weeks at Newcomb, NY. Laboratory tests indicated that relative humidity alone did not cause sensors to become saturated with water. However, the rates of drying indicated by the sensors after an initial saturation were inversely related to the relative humidity. On-site testing of the relative-humidity probe and the gypsum-coated ciruit grid indicated that they respond to a diurnal wetting and drying cycle; the limestone-block resistor responded only to rainfall.

  14. Dynamic analysis of the reactor building for soft (Kozloduy) and hard (Temelin) soil conditions and different seismic loading

    International Nuclear Information System (INIS)

    Krutzik, N.

    1995-01-01

    Analyses were conducted for the reactor building to determine the dynamic responses of the coupled system, soil and structure and the forces in the characteristic structural members. This report summarizes the results of structural dynamic analyses derived for soft and hard soil conditions by the modal time history method using substructure models as well as (for soft soil conditions) in the frequency domain using complex (coupled) models of the soil and the structure. The mathematical model of the reactor building is represented as a lumped mass beam model. The capabilities of the soil were represented by means of global frequency independent springs and dampers (substructure models) or by an appropriate final element model. The results of the above-mentioned analysis presented in this report comprise in particular the maximum values of accelerations, displacements and internal forces as well as the acceleration response spectra for the relevant building regions. The time domain (modal time history) calculations were performed for real soil conditions which corresponds to the site Kozloduy (soft) and Temelin (hard). As seismic input data the corresponding free-field data here been used. The dynamic response obtained for the soft-soil conditions using both type of (substructure and complex) models were compared and demonstrated in one plot. Similar comparison were performed for the results obtained for soft and hard soil conditions

  15. Trust building electronic services as a crucial self-regulation feature of Digital Business Ecosystems

    Directory of Open Access Journals (Sweden)

    Radoslav Delina

    2012-04-01

    Full Text Available In the field of digital business ecosystem, the self-regulation feature plays crucial role. ICT supports biological and sociological phenomena through efficient electronic services. One of the main roles is building and enhancing efficient relationships between actors within the ecosystem. Problem of interaction between commercial subjects depends on expected benefits. These expectations are predictors of successful result from realized transaction with potential partner. And this predictor is based on trust and trustworthiness. The paper presents trust as crucial factor for cooperation and discusses specifics of several trust building mechanisms to increase the level of trust in e-cooperation within digital business ecosystems. Based on results provided by questionnaire survey in Slovak business environment, the paper discusses the relationship between the level of respondents´ electronic business experience and their preferences for the portfolio of trust building mechanisms.

  16. Radon levels in domestic dwellings built since the introduction of the 1997 building regulations. Report of a pilot survey in Ennis, County Clare

    International Nuclear Information System (INIS)

    Synnott, H.; Pollard, D.; Colgan, P.A.

    2003-04-01

    Amending Building Regulations were introduced in December 1997, which require that measures be taken during construction to prevent the entry of radon into buildings from the underlying soil. These Regulations apply to buildings built on or after the 1 July 1998. During 2001, the Radiological Protection Institute of Ireland (RPII) undertook a pilot study of radon levels in houses built since that date with the aim of assessing the impact of these new Regulations. The area selected for this study was the 10 km Irish National Grid square including the town of Ennis, Co Clare. The RPII's National Radon Survey predicts that 27% of all dwellings in this grid square have radon concentrations in excess of the national Reference Level of 200 Bq/m3. Two hundred and seventy nine householders, whose houses were built since the amending Regulations came into effect, were invited to participate in a free survey and 97 of these agreed to do so. Participating householders were asked to complete a questionnaire aimed at assessing their knowledge of the radon preventive measures included in their house. Twelve percent of the houses measured in this survey were found to have radon levels in excess of the national Reference Level. This figure indicates a significant reduction as compared with the National Radon Survey prediction for the same grid square. It is difficult, however, to draw definitive conclusions from these data regarding the effectiveness of the new Regulations due to the very different age distribution for the two sets of houses and differences between current and historic building practices. Further work is underway comparing radon levels in houses built both immediately before and after the introduction of the 1997 Regulations, which aims to address outstanding questions. Householders' level of awareness of the radon preventive measures included in their house was low; 45% and 36% respectively of respondents were unaware of whether their house had a radon sump or

  17. Resilience among first responders | Pietrantoni | African Health ...

    African Journals Online (AJOL)

    Nine hundred and sixty-one first responders filled out an on-line questionnaire, containing measure of sense of community, collective efficacy, self-efficacy and work-related mental health outcomes (compassion fatigue, burnout and compassion satisfaction). Results. First responders reported high level of compassion ...

  18. Effects on stereotypy and other challenging behavior of matching rates of instruction to free-operant rates of responding.

    Science.gov (United States)

    Johnson, Jesse W; Van Laarhoven, Toni; Repp, Alan C

    2002-01-01

    Research has shown that when individuals are in situations that do not occasion one form of motoric responding, they will engage in another so that the overall level of motoric responding is homeostatic. The purpose of this study was to test whether students would substitute task-related behaviors for stereotypic or other challenging behaviors when the opportunity for active responding did or did not match the level of motoric responding in a free-operant baseline. Four students with mental retardation participated. Results showed that they did substitute behaviors, with stereotypic and other challenging behaviors occurring 1.5-14 times as much in the Non-matched condition for the four students. Further analysis showed considerably more of these behaviors in passive than in active tasks (by a factor up to 21 times as much). Results were discussed in terms of homeostasis, functional assessment, and opportunities to improve educational behaviors.

  19. Use of Personal Protective Equipment among Building Construction Workers in Kampala, Uganda

    Directory of Open Access Journals (Sweden)

    Jonathan Izudi

    2017-01-01

    Full Text Available Background. 270 million workplace accidents occur annually. In Uganda, Kampala district has the highest workplace injury and fatality rates. However, information on personal protective equipment (PPE—hand gloves, hardhats, overalls, safety boots, earplugs, safety harness with lanyard, and face shields—utilization among building construction workers remains scarce. We assessed PPE utilization and determinants among building construction workers in Kampala, Uganda. Methods. This cross-sectional study involved 385 respondents. Data collected by structured questionnaire was double-entered in EpiData and analyzed in STATA at 5% significance level. Independent determinants of PPE use were established by a stepwise backward logistic regression analysis. Results. 305 (79.2% respondents were males, 290 (75.3% were 18–30 years, 285 (74.0% completed secondary education, and 197 (51.2% were temporary employees. 60 (15.6% respondents used PPE. Female sex (adjusted odds ratio (AOR = 6.64; 95% CI: 1.55–28.46; P=0.011, temporary (AOR = 0.05; 95% CI: 0.01–0.27; P<0.001 and casual (AOR = 0.01; 95% CI: 0.001–0.071; P<0.001 employment, and previous knowledge of safety measures (AOR = 100.72; 95% CI: 26.00–390.16; P<0.001 were associated with PPE use. Conclusion. PPE use was low in Kampala, Uganda. Building construction companies should implement measures of the Uganda Occupational Health and Safety Act.

  20. A hybrid energy efficient building ventilation system

    International Nuclear Information System (INIS)

    Calay, Rajnish Kaur; Wang, Wen Chung

    2013-01-01

    The present paper presents a high performance cooling/heating ventilation system using a rotary heat exchanger (RHE), together with a reverse-cycle heat pump (RCHP) that can be integrated with various heat sources. Energy consumption in the building sector is largely dominated by the energy consumed in maintaining comfortable conditions indoors. For example in many developed countries the building heating, ventilation and air conditioning (HVAC) systems consume up to 50% of the total energy consumed in buildings. Therefore energy efficient HVAC solutions in buildings are critical for realising CO 2 targets at local and global level. There are many heating/cooling concepts that rely upon renewable energy sources and/or use natural low temperature heat sources in the winter and heat sinks in the summer. In the proposed system, waste energy from the exhaust air stream is used to precondition the outdoor air before it is supplied into the building. The hybrid system provides heating in the winter and cooling in the summer without any need for additional heating or cooling devices as required in conventional systems. Its performance is better than a typical reheat or air conditioning system in providing the same indoor air quality (IAQ) levels. It is shown that an energy saving up to 60% (heat energy) is achieved by using the proposed hybrid system in building ventilation applications. -- Highlights: • Hybrid ventilation system: the hybrid ventilation system uses a rotating regenerator and a reversible heat pump. • Heat recovery: heat recovery from exhaust air stream by rotary wheel type heat exchanger. • Reversible cycle heat pump (RCHP): additional heating or cooling of the supply air is provided by the RCHP. • Energy efficiency: energy savings of up to 60% using the proposed system are achievable

  1. Ventilation-air conditioning system

    International Nuclear Information System (INIS)

    Kubokoya, Takashi.

    1991-01-01

    Heretofore, in ventilation-air conditioning systems in a nuclear power plant, exhaust gases from each of the ventilation-air conditioning systems of a reactor building, a turbine building, a waste processing building are joined and they are released into atmosphere from the top of a high main exhaustion stack. In order to build such a high main exhaustion stack, a considerable construction cost is required and, in addition, there is a worry of lacking balance with surrounding scenery. Then, in the present invention, exhaust gases are heated by waste heat in a turbine during their introduction from the ventilation-air conditioning facility in the building of a power plant to the main exhaust stack. With such a constitution, since the exhaust gases are heated and their temperature is elevated, they uprise by natural convection when they are released from the top of the main exhaustion stack to the atmosphere. Accordingly, they are released to a level higher than the conventional case in view of the volume of the blower which sends the exhaust gases under pressure, to diffuse them to the atmosphere more sufficiently compared with a conventional case. Further, the height of the main exhaustion stack can be reduced, enabling to minimize the cost for moving the blower. (T.M.)

  2. Natural radiation and radon concentration in buildings

    International Nuclear Information System (INIS)

    Ito, Kazuo; Asano, Kenji

    1985-01-01

    The purpose of this subject is to investigate the actual conditions of natural radiation levels in various types of buildings. This study is indispensable for the accurate evaluation of population dose of external and internal exposures from natural radiation. Concentrations of K-40, Ra-226 and Th-232 in building materials such as Portland cement, gypsum boards and its raw materials were measured with Ge gamma spectrometer. (author)

  3. Building integrated photovoltaics

    NARCIS (Netherlands)

    Ritzen, M.J.; Vroon, Z.A.E.P.; Geurts, C.P.W.; Reinders, Angèle; Verlinden, Pierre; Sark, Wilfried; Freundlich, Alexandre

    2017-01-01

    Photovoltaic (PV) installations can be realized in different situations and on different scales, such as at a building level. PV installations at the building level can either be added to the building envelope, which is called building added PV (BAPV), or they can be integrated into the building

  4. Non-destructive examination and estimation of radioactivity levels for decorative building materials

    International Nuclear Information System (INIS)

    Mao Yahong; Liu Yigang; Lin Libin

    2003-01-01

    Measurement of gamma ray intensity from building materials can be substituted by measuring alpha rays following outline of a radionuclide decay. Exposure levels of alpha ray from the surface of decorative materials can be measured non-destructively by placing a detector on the surface of the materials. Authors have studied the relationship between gamma specific activities of natural radionuclides and alpha and beta ray level in building materials used in interior decoration, and the saturated thickness of beta ray from the surface of different materials. The results showed that the range of beta ray with the maximum energy in natural radioactive series is longer than thickness of a piece of decorative materials. So the exposure level of beta ray cannot be used to estimate the limit of external and internal indexes. The polynomial between exposure level of alpha ray from surface (α) and external index (I γ ) for granite is: I γ =0.38 + 49.84α + 288.24α 2 . The measured values were in accordance with the values from the polynomial within 95%. The polynomial between exposure level of alpha ray from surface (α) and external index (Iγ) for polishing tiles is: I γ =0.42 + 343.55α-32999.66α 2 . The measured values were in accordance with the values from the polynomial within 90%

  5. Manual for first responders to a radiological emergency. Emergency preparedness and response. Publication date: June 2007

    International Nuclear Information System (INIS)

    2007-08-01

    Under Article 5.a(ii) of the Convention on Assistance in the Case of a Nuclear Accident or Radiological Emergency (Assistance Convention), one function of the IAEA is to collect and disseminate to States Parties and Member States information concerning methodologies, techniques and results of research relating to response to nuclear or radiological emergencies. As stated in IAEA Safety Standards Series No. GS-R-2 'Preparedness and Response for a Nuclear or Radiological Emergency', which establishes the requirements for an adequate level of preparedness for and response to a nuclear or radiological emergency in any State, 'first responders shall take all practicable and appropriate actions to minimize the consequences of a nuclear or radiological emergency'. The IAEA General Conference, in resolution GC(49)/RES/9, continues to encourage Member States 'to adopt the relevant Agency standards, procedures and practical tools' and underlines 'the need for first responders to have appropriate training for dealing with ionizing radiation during nuclear and radiological emergencies'. This publication is intended to assist in meeting these requirements and to fulfil Article 5 of the Assistance Convention. Its aim is to provide practical guidance for those who will respond during the first few hours to a radiological emergency (referred to here as 'first responders') and for national officials who would support this early response. It provides guidance in the form of action guides, instructions, and supporting data that can be easily applied by a State to build a basic capability to respond to a radiological emergency. This guidance should be adapted to fit the user State's organizational arrangements, language, terminology, concept of operation and capabilities. This report, published as part of the IAEA Emergency Preparedness and Response Series, replaces and builds on IAEA-TECDOC-1162 in the area of early response and first responders' actions. It takes account of the

  6. Manual for first responders to a radiological emergency. Emergency preparedness and response. Publication date: October 2006

    International Nuclear Information System (INIS)

    2006-10-01

    Under Article 5.a(ii) of the Convention on Assistance in the Case of a Nuclear Accident or Radiological Emergency (Assistance Convention), one function of the IAEA is to collect and disseminate to States Parties and Member States information concerning methodologies, techniques and results of research relating to response to nuclear or radiological emergencies. As stated in IAEA Safety Standards Series No. GS-R-2 'Preparedness and Response for a Nuclear or Radiological Emergency', which establishes the requirements for an adequate level of preparedness for and response to a nuclear or radiological emergency in any State, 'first responders shall take all practicable and appropriate actions to minimize the consequences of a nuclear or radiological emergency'. The IAEA General Conference, in resolution GC(49)/RES/9, continues to encourage Member States 'to adopt the relevant Agency standards, procedures and practical tools' and underlines 'the need for first responders to have appropriate training for dealing with ionizing radiation during nuclear and radiological emergencies'. This publication is intended to assist in meeting these requirements and to fulfil Article 5 of the Assistance Convention. Its aim is to provide practical guidance for those who will respond during the first few hours to a radiological emergency (referred to here as 'first responders') and for national officials who would support this early response. It provides guidance in the form of action guides, instructions, and supporting data that can be easily applied by a State to build a basic capability to respond to a radiological emergency. This guidance should be adapted to fit the user State's organizational arrangements, language, terminology, concept of operation and capabilities. This report, published as part of the IAEA Emergency Preparedness and Response Series, replaces and builds on IAEA-TECDOC-1162 in the area of early response and first responders' actions. It takes account of the

  7. Preindustrial versus postindustrial Architecture and Building Techniques

    DEFF Research Database (Denmark)

    Vestergaard, Inge

    2014-01-01

    How can preindustrial architecture inspire sustainable thinking in postindustrial architectural design? How can we learn from experience and how can social, economic and environmental conditions give perspectives and guide a knowledge based evolution of basic experience towards modern industriali......How can preindustrial architecture inspire sustainable thinking in postindustrial architectural design? How can we learn from experience and how can social, economic and environmental conditions give perspectives and guide a knowledge based evolution of basic experience towards modern...... industrialized building processes? Identification of sustainable parameters related to change in society, to building technique and to comfort are illustrated through two Danish building types, which are different in time, but similar in function. One representing evolution and experience based countryside...... fisherman’s house built around year 1700; and second a frontrunner suburban family house built year 2008. The analysis involves architectural, technical and comfort matters and will state the levels of design, social conditions, sustainable and energy efficient parameters. Results will show lessons learned...

  8. Building energy analysis of Electrical Engineering Building from DesignBuilder tool: calibration and simulations

    Science.gov (United States)

    Cárdenas, J.; Osma, G.; Caicedo, C.; Torres, A.; Sánchez, S.; Ordóñez, G.

    2016-07-01

    This research shows the energy analysis of the Electrical Engineering Building, located on campus of the Industrial University of Santander in Bucaramanga - Colombia. This building is a green pilot for analysing energy saving strategies such as solar pipes, green roof, daylighting, and automation, among others. Energy analysis was performed by means of DesignBuilder software from virtual model of the building. Several variables were analysed such as air temperature, relative humidity, air velocity, daylighting, and energy consumption. According to two criteria, thermal load and energy consumption, critical areas were defined. The calibration and validation process of the virtual model was done obtaining error below 5% in comparison with measured values. The simulations show that the average indoor temperature in the critical areas of the building was 27°C, whilst relative humidity reached values near to 70% per year. The most critical discomfort conditions were found in the area of the greatest concentration of people, which has an average annual temperature of 30°C. Solar pipes can increase 33% daylight levels into the areas located on the upper floors of the building. In the case of the green roofs, the simulated results show that these reduces of nearly 31% of the internal heat gains through the roof, as well as a decrease in energy consumption related to air conditioning of 5% for some areas on the fourth and fifth floor. The estimated energy consumption of the building was 69 283 kWh per year.

  9. Does contingency in adults' responding influence 12-month-old infants' social referencing?

    Science.gov (United States)

    Stenberg, Gunilla

    2017-11-01

    In two experiments we examined the influence of contingent versus non-contingent responding on infant social referencing behavior. EXPERIMENT 1: Forty 12-month-old infants were exposed to an ambiguous toy in a social referencing situation. In one condition an unfamiliar adult who in a previous play situation had responded contingently to the infant's looks gave the infant positive information about the toy. In the other condition an unfamiliar adult who previously had not responded contingently delivered the positive information. EXPERIMENT 2: Forty-eight 12-month-old infants participated in Experiment 2. In this experiment it was examined whether the familiarity of the adult influences infants' reactions to contingency in responding. In one condition a parent who previously had responded contingently to the infant's looks provided positive information about the ambiguous toy, and in the other condition a parent who previously had not responded contingently provided the positive information. The infants looked more at the contingent experimenter in Experimenter 1, and also played more with the toy after receiving positive information from the contingent experimenter. No differences in looking at the parent and in playing with the toy were found in Experiment 2. The results indicate that contingency in responding, as well as the familiarity of the adult, influence infants' social referencing behavior. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Time to reassess capacity-building partnerships

    Directory of Open Access Journals (Sweden)

    Brooke Lauten

    2007-07-01

    Full Text Available Since 2001 the Watchlist on Children and Armed Conflict has worked with local civil society organisations, child protection networks and grassroots organisations to build capacity to monitor and respond to abuses of children’s rights. Through our capacity-building partnerships, we work to shift the power structure that defines the roles of national and international NGO's in humanitarian programming.

  11. Artificial intelligence applications in fixed area monitor for TRIGA reactor building and service building

    International Nuclear Information System (INIS)

    Talpalariu, C.; Talpalariu, J.; Vaja, N.; Matei, C.

    2008-01-01

    This system is intended for the protection of personnel working in those areas of the Reactor Building and Service Building where high gamma radiation fields are expected. A detector, sensitive to gamma radiation, is installed in each of the areas to be monitored. The detector will send a signal, proportional to the radiation level in the area, to a corresponding electronic module (Alarm Unit), where the signal will be amplified and checked against alarm set points for possible alarming conditions. In case the field exceeds the alarm set values, the Alarm Unit will produce a signal that will trigger the field alarms (Horn and Beacon) located in the area where the condition occurred. Each Alarm Unit will send a numerical input to central computer command. he system is required to accomplish the following tasks: - Monitors the level of gamma radiation in those areas of the Station where high radiation fields are expected; - Provides a continuous and centralized display of the radiation level in each of the monitored areas. The display shall be in exposure rate units (R/h); - Provides a visual and audible alarm in each monitored areas; Allows the control room operator to check at any time the radiation levels and alarm conditions in each of the monitored areas; - Control room operator shall be alerted of any alarm conditions that occurs in the Station. A typical monitoring loop is composed of the following components: Detector Assembly type: CI-MA - 522 two channels, two ranges; Horn and Beacon Assembly; Remote Indicating Meter with Warning Lights; Central computer; common equipment for all 40 loops. (authors)

  12. Demand Forecasting at Low Aggregation Levels using Factored Conditional Restricted Boltzmann Machine

    DEFF Research Database (Denmark)

    Mocanu, Elena; Nguyen, Phuong H.; Gibescu, Madeleine

    2016-01-01

    electric power consumption, local price and meteorological data collected from 1900 customers. The households are equipped with local generation and smart appliances capable of responding to realtime pricing signals. The results show that for the short-term (5 minute to 1 day ahead) prediction problems......The electrical demand forecasting problem can be regarded as a nonlinear time series prediction problem depending on many complex factors since it is required at various aggregation levels and at high temporal resolution. To solve this challenging problem, various time series and machine learning...... developed deep learning model for time series prediction, namely Factored Conditional Restricted Boltzmann Machine (FCRBM), and extend it for electrical demand forecasting. The assessment is made on the EcoGrid dataset, originating from the Bornholm island experiment in Denmark, consisting of aggregated...

  13. INDOOR THERMAL CONDITION OF FACTORY BUILDING IN BANGLADESH

    Directory of Open Access Journals (Sweden)

    Muhammed Abdullah Al Sayem Khan

    2011-12-01

    Full Text Available Bangladesh is a developing country and has a lot of factories for different products for local use and also export to abroad. Garments industries are one of the top most items of exported items. A huge number of populations are working in garments industries. But these factories are not well designed in sense of the thermal environment. Workers experiences sickness related to indoor environment. The productions of these factories are affected due to employees’ health condition. The research is done in two different methods. One is empirical data collection using thermal data loggers and the other is questionnaire survey on the spots for three factory buildings. The field study was conducted in four different months of the same year during winter and summer period. Expected findings of this research are that the indoor environment is not comfortable for works at day time during summer season. This research will help the factory workers in providing a comfortable thermal environment and also help the employers or factory owners to increase their production margin.

  14. Handling and storage of conditioned high-level wastes

    International Nuclear Information System (INIS)

    1983-01-01

    This report deals with certain aspects of the management of one of the most important wastes, i.e. the handling and storage of conditioned (immobilized and packaged) high-level waste from the reprocessing of spent nuclear fuel and, although much of the material presented here is based on information concerning high-level waste from reprocessing LWR fuel, the principles, as well as many of the details involved, are applicable to all fuel types. The report provides illustrative background material on the arising and characteristics of high-level wastes and, qualitatively, their requirements for conditioning. The report introduces the principles important in conditioned high-level waste storage and describes the types of equipment and facilities, used or studied, for handling and storage of such waste. Finally, it discusses the safety and economic aspects that are considered in the design and operation of handling and storage facilities

  15. Handling and storage of conditioned high-level wastes

    International Nuclear Information System (INIS)

    Heafield, W.

    1984-01-01

    This paper deals with certain aspects of the management of one of the most important radioactive wastes arising from the nuclear fuel cycle, i.e. the handling and storage of conditioned high-level wastes. The paper is based on an IAEA report of the same title published during 1983 in the Technical Reports Series. The paper provides illustrative background material on the characteristics of high-level wastes and, qualitatively, their requirements for conditioning. The principles important in the storage of high-level wastes are reviewed in conjunction with the radiological and socio-political considerations involved. Four fundamentally different storage concepts are described with reference to published information and the safety aspects of particular storage concepts are discussed. Finally, overall conclusions are presented which confirm the availability of technology for constructing and operating conditioned high-level waste storage facilities for periods of at least several decades. (author)

  16. Solar Systems for Heating and Cooling of Buildings

    OpenAIRE

    Henning, Hans-Martin; Döll, Jochen

    2012-01-01

    Recently, the concept of net zero energy buildings has become a major topic in the R&D work on future buildings. In order to achieve a zero energy balance on annual level energy saving and energy efficiency measures have to be fully exploited. However, a demand for active heating and/or cooling will remain in most buildings and under most climatic conditions. Solar energy is the main on-site renewable energy source which can be used to achieve a high fraction of renewable energies to cover th...

  17. Comfort air temperature influence on heating and cooling loads of a residential building

    Science.gov (United States)

    Stanciu, C.; Șoriga, I.; Gheorghian, A. T.; Stanciu, D.

    2016-08-01

    The paper presents the thermal behavior and energy loads of a two-level residential building designed for a family of four, two adults and two students, for different inside comfort levels reflected by the interior air temperature. Results are intended to emphasize the different thermal behavior of building elements and their contribution to the building's external load. The most important contributors to the building thermal loss are determined. Daily heating and cooling loads are computed for 12 months simulation in Bucharest (44.25°N latitude) in clear sky conditions. The most important aspects regarding sizing of thermal energy systems are emphasized, such as the reference months for maximum cooling and heating loads and these loads’ values. Annual maximum loads are encountered in February and August, respectively, so these months should be taken as reference for sizing thermal building systems, in Bucharest, under clear sky conditions.

  18. Building Support for Adolescent Sexuality and Reproductive Health Education and Responding to Resistance in Conservative Contexts: Cases From Pakistan.

    Science.gov (United States)

    Chandra-Mouli, Venkatraman; Plesons, Marina; Hadi, Sheena; Baig, Qadeer; Lang, Iliana

    2018-03-21

    Despite international recommendations and supportive evidence, there are few examples of scaled-up and sustained programs to provide adolescents with sexuality education. Moreover, despite acknowledgment that building community support and responding to resistance are key challenges, there is a lack of detailed discussion on specific programmatic strategies to address these issues. This article reviews the work of 2 organizations-Aahung and Rutgers Pakistan-that are successfully implementing large-scale sexuality education programs in Pakistan, collectively reaching more than 500,000 students. This review aims to answer the following questions: (1) How did Aahung and Rutgers Pakistan work to understand Pakistani society and culture and shape their programs to build community support? (2) How did Aahung and Rutgers Pakistan overcome resistance to their efforts? We reviewed program documents and publications, synthesized key themes, identified questions of interest, and engaged key informants from Aahung and Rutgers Pakistan's leadership. The success of Aahung and Rutgers Pakistan was grounded in their readiness to understand the nuanced context within the communities, collaborate with groups of stakeholders-including parents, school officials, religious leaders, media personnel, and adolescents themselves-to ensure support, and stand up to forces of resistance to pursue their goals. Specific strategies included working with communities to select content, tactfully selecting and framing issues with careful consideration for sensitivities, engaging adolescents' influencers, strengthening media presence, showcasing school programs to increase understanding and transparency, and choosing opportune times to introduce messages. The successful strategies used by Aahung and Rutgers Pakistan to promote adolescent sexual and reproductive health through sexuality education can inform programs worldwide. Additionally, the programmatic weaknesses identified can guide future

  19. Energy management systems in buildings

    Energy Technology Data Exchange (ETDEWEB)

    Lush, D. M.

    1979-07-01

    An investigation is made of the range of possibilities available from three types of systems (automatic control devices, building envelope, and the occupants) in buildings. The following subjects are discussed: general (buildings, design and personnel); new buildings (envelope, designers, energy and load calculations, plant design, general design parameters); existing buildings (conservation measures, general energy management, air conditioned buildings, industrial buildings); man and motivation (general, energy management and documentation, maintenance, motivation); automatic energy management systems (thermostatic controls, optimized plant start up, air conditioned and industrial buildings, building automatic systems). (MCW)

  20. Extreme groundwater levels caused by extreme weather conditions - the highest ever measured groundwater levels in Middle Germany and their management

    Science.gov (United States)

    Reinstorf, F.; Kramer, S.; Koch, T.; Pfützner, B.

    2017-12-01

    Extreme weather conditions during the years 2009 - 2011 in combination with changes in the regional water management led to maximum groundwater levels in large areas of Germany in 2011. This resulted in extensive water logging, with problems especially in urban areas near rivers, where water logging produced huge problems for buildings and infrastructure. The acute situation still exists in many areas and requires the development of solution concepts. Taken the example of the Elbe-Saale-Region in the Federal State of Saxony-Anhalt, were a pilot research project was carried out, the analytical situation, the development of a management tool and the implementation of a groundwater management concept are shown. The central tool is a coupled water budget - groundwater flow model. In combination with sophisticated multi-scale parameter estimation, a high-resolution groundwater level simulation was carried out. A decision support process with an intensive stakeholder interaction combined with high-resolution simulations enables the development of a management concept for extreme groundwater situations in consideration of sustainable and environmentally sound solutions mainly on the base of passive measures.

  1. Source term evaluation model for high-level radioactive waste repository with decay chain build-up.

    Science.gov (United States)

    Chopra, Manish; Sunny, Faby; Oza, R B

    2016-09-18

    A source term model based on two-component leach flux concept is developed for a high-level radioactive waste repository. The long-lived radionuclides associated with high-level waste may give rise to the build-up of activity because of radioactive decay chains. The ingrowths of progeny are incorporated in the model using Bateman decay chain build-up equations. The model is applied to different radionuclides present in the high-level radioactive waste, which form a part of decay chains (4n to 4n + 3 series), and the activity of the parent and daughter radionuclides leaching out of the waste matrix is estimated. Two cases are considered: one when only parent is present initially in the waste and another where daughters are also initially present in the waste matrix. The incorporation of in situ production of daughter radionuclides in the source is important to carry out realistic estimates. It is shown that the inclusion of decay chain build-up is essential to avoid underestimation of the radiological impact assessment of the repository. The model can be a useful tool for evaluating the source term of the radionuclide transport models used for the radiological impact assessment of high-level radioactive waste repositories.

  2. Thermal stress analysis of reactor containment building considering severe weather condition

    International Nuclear Information System (INIS)

    Lee, Yun; Kim, Yun-Yong; Hyun, Jung-Hwan; Kim, Do-Gyeum

    2014-01-01

    Highlights: • We examine that through-wall crack risk in cold weather is high. • It is predicted that cracking in concrete wall will not happen in hot region. • Cracking due to hydration heat can be controlled by appropriate curing condition. • Temperature differences between inner and outer face is relatively small in hot weather. - Abstract: Prediction of concrete cracking due to hydration heat in mass concrete such as reactor containment building (RCB) in nuclear power plant is a crucial issue in construction site. In this study, the numerical analysis for heat transfer and stress development is performed for the containment wall in RCB by considering the severe weather conditions. Finally, concrete cracking risk in hot and cold weather is discussed based on analysis results. In analyses considering severe weather conditions, it is found that the through-wall cracking risk in cold weather is high due to the abrupt temperature difference between inside concrete and the ambient air in cold region. In hot weather, temperature differences between inner and outer face is relatively small, and accordingly the relevant cracking risk is relatively low in contrast with cold weather

  3. Experiences of building a medical data acquisition system based on two-level modeling.

    Science.gov (United States)

    Li, Bei; Li, Jianbin; Lan, Xiaoyun; An, Ying; Gao, Wuqiang; Jiang, Yuqiao

    2018-04-01

    Compared to traditional software development strategies, the two-level modeling approach is more flexible and applicable to build an information system in the medical domain. However, the standards of two-level modeling such as openEHR appear complex to medical professionals. This study aims to investigate, implement, and improve the two-level modeling approach, and discusses the experience of building a unified data acquisition system for four affiliated university hospitals based on this approach. After the investigation, we simplified the approach of archetype modeling and developed a medical data acquisition system where medical experts can define the metadata for their own specialties by using a visual easy-to-use tool. The medical data acquisition system for multiple centers, clinical specialties, and diseases has been developed, and integrates the functions of metadata modeling, form design, and data acquisition. To date, 93,353 data items and 6,017 categories for 285 specific diseases have been created by medical experts, and over 25,000 patients' information has been collected. OpenEHR is an advanced two-level modeling method for medical data, but its idea to separate domain knowledge and technical concern is not easy to realize. Moreover, it is difficult to reach an agreement on archetype definition. Therefore, we adopted simpler metadata modeling, and employed What-You-See-Is-What-You-Get (WYSIWYG) tools to further improve the usability of the system. Compared with the archetype definition, our approach lowers the difficulty. Nevertheless, to build such a system, every participant should have some knowledge in both medicine and information technology domains, as these interdisciplinary talents are necessary. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Reactor building

    International Nuclear Information System (INIS)

    Ebata, Sakae.

    1990-01-01

    At least one valve rack is disposed in a reactor building, on which pipeways to a main closure valve, valves and bypasses of turbines are placed and contained. The valve rack is fixed to the main body of the building or to a base mat. Since the reactor building is designed as class A earthquake-proofness and for maintaining the S 1 function, the valve rack can be fixed to the building main body or to the base mat. With such a constitution, the portions for maintaining the S 1 function are concentrated to the reactor building. As a result, the dispersion of structures of earthquake-proof portion corresponding to the reference earthquake vibration S 1 can be prevented. Accordingly, the conditions for the earthquake-proof design of the turbine building and the turbine/electric generator supporting rack are defined as only the class B earthquake-proof design conditions. In view of the above, the amount of building materials can be saved and the time for construction can be shortened. (I.S.)

  5. A program-level management system for the life cycle environmental and economic assessment of complex building projects

    International Nuclear Information System (INIS)

    Kim, Chan-Joong; Kim, Jimin; Hong, Taehoon; Koo, Choongwan; Jeong, Kwangbok; Park, Hyo Seon

    2015-01-01

    Climate change has become one of the most significant environmental issues, of which about 40% come from the building sector. In particular, complex building projects with various functions have increased, which should be managed from a program-level perspective. Therefore, this study aimed to develop a program-level management system for the life-cycle environmental and economic assessment of complex building projects. The developed system consists of three parts: (i) input part: database server and input data; (ii) analysis part: life cycle assessment and life cycle cost; and (iii) result part: microscopic analysis and macroscopic analysis. To analyze the applicability of the developed system, this study selected ‘U’ University, a complex building project consisting of research facility and residential facility. Through value engineering with experts, a total of 137 design alternatives were established. Based on these alternatives, the macroscopic analysis results were as follows: (i) at the program-level, the life-cycle environmental and economic cost in ‘U’ University were reduced by 6.22% and 2.11%, respectively; (ii) at the project-level, the life-cycle environmental and economic cost in research facility were reduced 6.01% and 1.87%, respectively; and those in residential facility, 12.01% and 3.83%, respective; and (iii) for the mechanical work at the work-type-level, the initial cost was increased 2.9%; but the operation and maintenance phase was reduced by 20.0%. As a result, the developed system can allow the facility managers to establish the operation and maintenance strategies for the environmental and economic aspects from a program-level perspective. - Highlights: • A program-level management system for complex building projects was developed. • Life-cycle environmental and economic assessment can be conducted using the system. • The design alternatives can be analyzed from the microscopic perspective. • The system can be used to

  6. A program-level management system for the life cycle environmental and economic assessment of complex building projects

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chan-Joong [Parsons Brinckerhoff, Seoul 135-763 (Korea, Republic of); Kim, Jimin; Hong, Taehoon; Koo, Choongwan; Jeong, Kwangbok; Park, Hyo Seon [Department of Architectural Engineering, Yonsei University, Seoul 120-749 (Korea, Republic of)

    2015-09-15

    Climate change has become one of the most significant environmental issues, of which about 40% come from the building sector. In particular, complex building projects with various functions have increased, which should be managed from a program-level perspective. Therefore, this study aimed to develop a program-level management system for the life-cycle environmental and economic assessment of complex building projects. The developed system consists of three parts: (i) input part: database server and input data; (ii) analysis part: life cycle assessment and life cycle cost; and (iii) result part: microscopic analysis and macroscopic analysis. To analyze the applicability of the developed system, this study selected ‘U’ University, a complex building project consisting of research facility and residential facility. Through value engineering with experts, a total of 137 design alternatives were established. Based on these alternatives, the macroscopic analysis results were as follows: (i) at the program-level, the life-cycle environmental and economic cost in ‘U’ University were reduced by 6.22% and 2.11%, respectively; (ii) at the project-level, the life-cycle environmental and economic cost in research facility were reduced 6.01% and 1.87%, respectively; and those in residential facility, 12.01% and 3.83%, respective; and (iii) for the mechanical work at the work-type-level, the initial cost was increased 2.9%; but the operation and maintenance phase was reduced by 20.0%. As a result, the developed system can allow the facility managers to establish the operation and maintenance strategies for the environmental and economic aspects from a program-level perspective. - Highlights: • A program-level management system for complex building projects was developed. • Life-cycle environmental and economic assessment can be conducted using the system. • The design alternatives can be analyzed from the microscopic perspective. • The system can be used to

  7. Preserving the acoustical heritage of historical buildings

    DEFF Research Database (Denmark)

    Rindel, Jens Holger

    2005-01-01

    with the present state building. Next step is to identify what historic conditions that should be reconstructions, especially architectural details, surface materials, obstacles, textiles, performing persons and audience, and typical sounds or music. The computer model is then modified according to these data......The use of virtual reality and auralization techniques has opened new possibilities for the study of acoustical conditions in historic buildings. With reference to some recent and current projects the paper describes the steps in the process and how new technology may be used to overcome some...... of the difficulties involved. If the building exists as a whole or partly the first step is collection of geometrical and architectural data from the site. The level of detail may be huge, e.g. if laser scanning is used for providing the geometrical data, and some degree of simplification may be necessary...

  8. Capacity-building activities for local leadership in Egypt from the local to the national and regional levels.

    Science.gov (United States)

    El Sioufi, M

    1996-03-01

    In order to make the Sustainable Ismailia Project institutionally sustainable, the National Project Manager identified the need to build the capacity of local leadership. The Training Section, in UNCHS, proposed a capacity-building program designed to respond to this demand focusing on the skill-training and attitude formation needed for effective local leadership. The proposed program is adapted from the "Training for Elected Leadership" series widely tested and used in many regions. It combines direct training for local officials from villages in Ismailia, and indirect training for trainers from the Ministry of Local Administration (MLA). After the course, the MLA trainers would design a training program which they will implement nationally. The Minister for Local Administration decided to finance the translation and production of the manuals, while the Governor of Ismailia offered to cover the trainees' expenses. The UNCHS Training and Capacity-Building Section would provide technical guidance and coordinate and implement the program. Once the Arabic version of the training materials would be available, UNCHS would use it regionally to reach out to other Arab States. This example illustrates how concerned stakeholders cooperate to address capacity-building needs. The UNCHS Training Section assumes the role of facilitator and acts as a catalyst for the formulation of such activities. The feeling of ownership of the locally produced/adapted training materials enhances the propensity of their effective and extensive use. This approach has succeeded across regions, cultures, and languages with out-reaching multiplier effects. full text

  9. Cooling energy efficiency and classroom air environment of a school building operated by the heat recovery air conditioning unit

    International Nuclear Information System (INIS)

    Wang, Yang; Zhao, Fu-Yun; Kuckelkorn, Jens; Liu, Di; Liu, Li-Qun; Pan, Xiao-Chuan

    2014-01-01

    The recently-built school buildings have adopted novel heat recovery ventilator and air conditioning system. Heat recovery efficiency of the heat recovery facility and energy conservation ratio of the air conditioning unit were analytically modeled, taking the ventilation networks into account. Following that, school classroom displacement ventilation and its thermal stratification and indoor air quality indicated by the CO 2 concentration have been numerically modeled concerning the effects of delivering ventilation flow rate and supplying air temperature. Numerical results indicate that the promotion of mechanical ventilation rate can simultaneously boost the dilution of indoor air pollutants and the non-uniformity of indoor thermal and pollutant distributions. Subsequent energy performance analysis demonstrates that classroom energy demands for ventilation and cooling could be reduced with the promotion of heat recovery efficiency of the ventilation facility, and the energy conservation ratio of the air conditioning unit decreases with the increasing temperatures of supplying air. Fitting correlations of heat recovery ventilation and cooling energy conservation have been presented. - Highlights: • Low energy school buildings and classroom environment. • Heat recovery facility operating with an air conditioning unit. • Displacement ventilation influenced by the heat recovery efficiency. • Energy conservation of cooling and ventilation through heat recovery. • Enhancement of classroom environment with reduction of school building energy

  10. Innovative Strategies for Building Community Resilience: Lessons from the Frontlines of Climate Change Capacity-Building

    Science.gov (United States)

    Abrash Walton, A.

    2017-12-01

    There is broad scientific consensus that climate change is occurring; however, there is limited implementation of measures to create resilient local communities (Abrash Walton, Simpson, Rhoades, & Daniels, 2016; Adger, Arnell, & Tompkins, 2005; Glavovic & Smith, 2014; Moser & Ekstrom, 2010; Picketts, Déry, & Curry, 2014). Communities that are considered climate leaders in the United States may have adopted climate change plans, yet few have actually implemented the policies, projects and recommendations in those plans. A range of innovative, education strategies have proven effective in building the capacity of local decision makers to strengthen community resilience. This presentation draws on the results of two years of original research regarding the information and support local decision makers require for effective action. Findings are based on information from four datasets, with more than 600 respondents from 48 U.S. states and 19 other countries working on local adaptation in a range of capacities. These research results can inform priority setting for public policy, budget setting, and action as well as private sector funding and investment. The presentation will focus, in particular, on methods and results of a pioneering Facilitated Community of Practice model (FCoP) for building climate preparedness and community resilience capacity, among local-level decision makers. The FCoP process includes group formation and shared capacity building experience. The process can also support collective objective setting and creation of structures and processes for ongoing sustainable collaboration. Results from two FCoPs - one fully online and the other hybrid - suggest that participants viewed the interpersonal and technical assistance elements of the FCoP as highly valuable. These findings suggest that there is an important need for facilitated networking and other relational aspects of building capacity among those advancing resilience at the local level.

  11. Vital analysis: annotating sensed physiological signals with the stress levels of first responders in action.

    Science.gov (United States)

    Gomes, P; Kaiseler, M; Queirós, C; Oliveira, M; Lopes, B; Coimbra, M

    2012-01-01

    First responders such as firefighters are exposed to extreme stress and fatigue situations during their work routines. It is thus desirable to monitor their health using wearable sensing but this is a complex and still unsolved research challenge that requires large amounts of properly annotated physiological signals data. In this paper we show that the information gathered by our Vital Analysis Framework can support the annotation of these vital signals with the stress levels perceived by the target user, confirmed by the analysis of more than 4600 hours of data collected from real firefighters in action, including 717 answers to event questionnaires from a total of 454 different events.

  12. Impacts of city-block-scale countermeasures against urban heat-island phenomena upon a building's energy-consumption for air-conditioning

    Energy Technology Data Exchange (ETDEWEB)

    Kikegawa, Yukihiro [Department of Environmental Systems, Meisei University, 2-1-1 Hodokubo, Hino-shi, Tokyo 191-8506 (Japan); Genchi, Yutaka [Research Center for Life Cycle Assessment, National Institute of Advanced Industrial Science and Technology, 16-1 Onogawa, Tsukuba, Ibaraki 305-8569 (Japan); Kondo, Hiroaki [Institute for Environmental Management Technology, National Institute of Advanced Industrial Science and Technology, 16-1 Onogawa, Tsukuba, Ibaraki 305-8569 (Japan); Hanaki, Keisuke [Department of Urban Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan)

    2006-06-15

    This study quantifies the possible impacts of urban heat-island countermeasures upon buildings' energy use during summer in Tokyo metropolis. Considering the dependency of the buildings air temperature upon the local urban canopy structure, Tokyo urban canopies were classified in the city-block-scale using the sky-view factor (svf). Then, a multi-scale model system describing the interaction between buildings' energy use and urban meteorological conditions was applied to each classified canopy. In terms of urban warming alleviation and cooling energy saving, simulations suggested that the reduction in the air-conditioning anthropogenic heat could be the most effective measure in office buildings' canopies, and that vegetative fraction increase on the side walls of buildings in residential canopies. Both measures indicated daily and spatially averaged decreases in near-ground summer air temperature of 0.2-1.2{sup o}C. The simulations also suggested these temperature decreases could result in the buildings' cooling energy-savings of 4-40%, indicating remarkable savings in residential canopies. These temperature drops and energy savings tended to increase with the decrease of the svf of urban canopies. (author)

  13. Measurements of the Received Signal Level and Service Coverage Area at the IEEE 802.11 Access Point in the Building

    Science.gov (United States)

    Gunantara, N.; Sudiarta, P. K.; Prasetya, AAN A. I.; Dharma, A.; Gde Antara, I. N.

    2018-04-01

    Access point (AP) is part of a Wireless Local Access Network (WLAN) with its communications using WiFi. AP is used to transmit and receive data to users/clients. The ability of AP to serve users/clients depends on many factors. Moreover, if AP is applied in conditions inside the building. In this study, AP is installed at two points inside the building and then measured in the form of the received signal level (RSL) and service coverage area. One AP measured its performance by 26 measurement points and the other AP measured its performance by 20 measurement points. When AP has measured its performance then another AP position is switched off. Based on the measurement result, the received signal level value is the highest value is about -47 dBm at a distance of 3.2 m, while the lowest is about -79 dBm at a 9.21 m because it is on barrier 2 walls. While based on service coverage area, the area which is far away from the AP then the quality of service becomes bad because the transmitted signal is weakening caused by the distance and the loss of the wall.

  14. Conditioning of intermediate-level waste at Forschungszentrum Juelich GmbH

    International Nuclear Information System (INIS)

    Krumbach, H.

    2003-01-01

    This contribution to the group of low-level, intermediate, mixed and hazardous waste describes the conditioning of intermediate-level mixed waste (dose rate above 10 mSv/h at the surface) from Research Centre Juelich (FZJ). Conditioning of the waste by supercompaction is performed at Research Centre Karlsruhe (FZK). The waste described is radioactive waste arising from research at Juelich. This waste includes specimens and objects from irradiation experiments in the research reactors Merlin (FRJ-1) and Dido (FRJ-2) at FZJ. In principle, radioactive waste at Forschungszentrum Juelich GmbH is differentiated by the surface dose rate at the waste package. Up to a surface dose rate of 10 mSv/h, the waste is regarded as low-level. The radioactive waste described here has a surface dose rate above 10 mSv/h. Waste up to 10 mSv/h is conditioned at the Juelich site according to different conditioning methods. The intermediate-level waste can only be conditioned by supercompaction in the processing facility for intermediate-level waste from plant operation at Research Centre Karlsruhe. Research Centre Juelich also uses this waste cell to condition its intermediate-level waste from plant operation. (orig.)

  15. Development of maintenance composite priority index for buildings in Palestine: A pilot case study

    Science.gov (United States)

    Issa, Amjad; Awad, Riyad

    2017-11-01

    The current building maintenance practices in Palestine are not based on scientific systematic methods. Most of the municipalities use one criterion to define the maintenance priorities, which is the "worst-first" criterion. Therefore, the current practices in defining buildings maintenance plans are not dealing with the known phases that are generally followed, including those in establishing building inventories, building condition survey, detailed visual inspection, identification of the proper maintenance and rehabilitation measures, and setting priorities. Accordingly, the recent preparation of the Operation and Maintenance (O&M) Manual for Palestinian municipalities is an important step to guide them towards preparing and implementing their O&M priority-based plans, considering scare resources. During the course of preparation of the Manual, the proposed procedures were applied at ten pilot municipalities. This study aims to explore the outcome of the implementation of the 2014/2015 O&M buildings maintenance priorities at these municipalities through the development of maintenance composite priority index (PI). The new proposed priority index is a scientific tool that will identify the priority of maintenance buildings through using a systematic procedure instead of first worst one. To achieve this, analyses of the outcome of a questionnaire designed to collect relevant information from these municipalities was conducted. The maintenance priority index for buildings is calculated considering different indicators among them building status (condition), classification and importance of the building, number of beneficiaries (users), safety aspects (severity level in the building), and people complaints. The main component of the PI is the building condition index (BCI) which forms about 40% of the total weight. The physical inspection, which is the main input for calculating the BCI, is conducted on two levels; the primary level, and the secondary level. The

  16. Radioactivity reference levels in ceramics tiles as building materials for different countries

    International Nuclear Information System (INIS)

    Ortiz, Josefina; Ballesteros, Luisa; Serradell, Vicente

    2008-01-01

    Measurements campaigns of ceramic tiles and raw materials used in them, shows that natural radionuclides of uranium ( 238 U) and thorium ( 232 Th) series, together with the radioactive isotope of potassium ( 40 K ), are presents. Uranium series contain radium, which decays to radon ( 222 Rn), an inert gas that can be released from materials and inhaled by individuals. Limits of 226 Ra concentrations are established by different countries in order to control Radon levels (200 Bq.m -3 in European Union). Potassium -40 and others gamma emitters of 226 Ra and 232 Th descendent, can cause an external dose. Therefore, with the purpose that individual doses due to building materials doesn't exceed a certain level recommendations or regulations have been established. A maximum value of 1 mSv.y -1 is recommended in European Union. In practice an easy way to avoid ceramic tiles provide doses to individuals over the reference level is to introduce an index, depending on activities concentrations of 226 Ra, 232 Th and 40 K, defined so that the dose limits due, exclusively, to building materials, will never be exceeded. These limits and indexes present differences between countries. In this paper indexes are compared and differences are discussed. (author)

  17. The effects of HVAC system design and operation on radon entry into school buildings

    International Nuclear Information System (INIS)

    Turner, W.A.; Leovic, K.W.; Craig, A.B.

    1990-01-01

    Heating, ventilating, and air conditioning (HVAC) systems in schools vary considerably and tend to have a greater impact on pressure differentials--and consequently radon levels--than do heating and air-conditioning systems in houses. If the HVAC system induces a negative pressure relative to the subslab area, radon can be pulled into the building. If the HVAC system pressurizes the building, it can prevent radon entry as long as the fan is running. However, school HVAC systems are normally set back or turned off on evenings and weekends and, even if the HVAC system pressurizes the school during operation, indoor radon levels may build up during setback periods. In this paper many of the historical methods utilized to deliver ventilation air (outdoor air) over the past 40 years are summarized. In addition, for each type of system presented, the possible impact the ventilation system might be expected to have (positive or negative) on the pressure of the building envelope (and subsequent radon levels in the building) is discussed

  18. Algae façade as green building method: application of algae as a method to meet the green building regulation

    Science.gov (United States)

    Poerbo, Heru W.; Martokusumo, Widjaja; Donny Koerniawan, M.; Aulia Ardiani, Nissa; Krisanti, Susan

    2017-12-01

    The Local Government of Bandung city has stipulated a Green Building regulation through the Peraturan Walikota Number 1023/2016. Signed by the mayor in October 2016, Bandung became the first city in Indonesia that put green building as mandatory requirement in the building permit (IMB) process. Green Building regulation is intended to have more efficient consumption of energy and water, improved indoor air quality, management of liquid and solid waste etc. This objective is attained through various design method in building envelope, ventilation and air conditioning system, lighting, indoor transportation system, and electrical system. To minimize energy consumption of buildings that have large openings, sun shading device is often utilized together with low-E glass panes. For buildings in hot humid tropical climate, this method reduces indoor air temperature and thus requires less energy for air conditioning. Indoor air quality is often done by monitoring the carbon dioxide levels. Application of algae as part of building system façade has recently been introduced as replacement of large glass surface in the building façade. Algae are not yet included in the green building regulation because it is relatively new. The research will investigate, with the help of the modelling process and extensive literature, how effective is the implementation of algae in building façade to reduce energy consumption and improve its indoor air quality. This paper is written based on the design of ITB Innovation Park as an ongoing architectural design-based research how the algae-integrated building façade affects the energy consumption.

  19. Self-leveling mortar as a possible cause of symptoms associated with "sick building syndrome".

    Science.gov (United States)

    Lundholm, M; Lavrell, G; Mathiasson, L

    1990-01-01

    In newly constructed houses and buildings in which self-leveling mortar containing casein has been used, residents and office employees have noted a bad odor and have complained of headache, eye and throat irritation, and tiredness. These problems were suspected to result from the degradation products emitted from the mortar. Samples obtained from dry mortar powder and from mortar in buildings where casein was used and from control buildings were found to contain microorganisms (mean of 10(2) culture forming units/g). Environmental species were predominantly found, e.g., Bacillus, Clostridium, Micrococcus, and Propionibacterium. Fungi were found occasionally; no evidence of bacterial degradation was found. Headspace and gas chromatographic-mass spectrometric analysis of air from the newly constructed houses and from hydroxide-degraded casein revealed the presence of amines in the 0.003-0.013 ppm range and the presence of ammonia and sulfhydryl compounds, all of which in low concentrations can cause the symptoms observed. These substances, however, were not detected in control buildings.

  20. Building a capacity building manual

    CSIR Research Space (South Africa)

    Clinton, DD

    2010-02-01

    Full Text Available Organizations 2010 Building a capacity building manual Daniel D. Clinton, Jr., P.E., F.NSPE Chair, WFEO Capacity Building Committee Dr Andrew Cleland, FIPENZ, Chief Executive, IPENZ, NZ Eng David Botha, FSAICE, Executive Director, SAICE, SA Dawit... 2010 Tertiary level University curricula Coaches and mentors Facilities EXCeeD Remuneration of Academics Experiential training Outreach to Students Students chapters Young members forum World Federation of Engineering Organizations 2010 Post...

  1. Low-Level, Measured Response of Los Alamos National Laboratories TA 16 - Building 411 and TA 8 - Building 23 to Direct Flash Attachment of Lightning

    International Nuclear Information System (INIS)

    Dinallo, Michael A.; Holmes, Parris; Merewether, Kimball O.; Morris, Marvin E.

    1999-01-01

    On September 24, 25, 28, and 29, 1998 and on October 19 and 23, 1998, transfer impedance measurements were made on Los Alamos National Laboratories TA 16 - Building 411 and TA 8-- Building 23 to characterize their interior open-circuit voltage response to a direct lightning flash attachment to the structures. The theory, history, measurement methods and equipment, and specific measured results are detailed. The measured results demonstrate that if the remaining metallic penetrations are bonded, then the rebar of the two structures is sufficiently well connected to form a Faraday cage that reduces the maximum open-circuit voltage inside the structure to a sufficiently low level that the required standoff distance to prevent arcing to explosive assemblies is 6.8 inches for TA 16 - Building 411 and is 11.5 inches for TA 8 - Building 23

  2. Differences in change in coping styles between good responders, moderate responders and non-responders to pulmonary rehabilitation.

    Science.gov (United States)

    Stoilkova-Hartmann, Ana; Janssen, Daisy J A; Franssen, Frits M E; Wouters, Emiel F M

    2015-12-01

    Pulmonary rehabilitation (PR) improves exercise tolerance and health status in patients with chronic obstructive pulmonary disease (COPD). Data on the effects of PR on coping styles are limited. Aim of the present study was to compare changes in coping styles between patients who had a good, moderate and no improvement in either exercise tolerance or health status after PR. Coping styles of 439 COPD patients undergoing PR were assessed by the Utrecht Coping List (UCL) at baseline and after PR. Patients' pulmonary function, six-minute walking distance (6MWD), St. George's Respiratory Questionnaire (SGRQ) and Hospital Anxiety and Depression Scale (HADS-A and HADS-D) were recorded. Good, moderate and non-responders were defined on the basis of minimally clinically important difference (MCID) for SGRQ total score and/or 6MWD. Overall, 54.0% of the patients fulfilled the criteria for good responders, while 22.1% were moderate responders. Change in passive reaction pattern coping style differed significantly between good responders and non-responders following PR (p styles after PR occurred among the good responders, whereas the majority of moderate responders' and non-responders' coping styles were not significantly influenced by PR. Good responders decreased their passive reaction pattern coping style in contrast to non-responders after PR. In general, PR did not change the coping among moderate and non-responders. Further research is warranted to determine whether including interventions targeting coping styles may modify coping behaviour of COPD patients, as well as improvement in exercise tolerance or health status after PR. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Nigerian Building Professionals’ Ethical Ideology and Perceived Ethical Judgement

    Directory of Open Access Journals (Sweden)

    John Oko Ameh

    2010-10-01

    Full Text Available In recent years, Nigeria is often cited in the international media in connection with corruption and other unethical practices. The professionals in the Nigerian building industry are not immune from the national trend in ethical erosion. Moral philosophy or ethical ideology has been used to explain individuals’ reasoning about moral issues and consequent behaviour. This study examines building industry professionals’ ethical ideologies with a view to understanding their ethical behaviour in professional practice.  In carrying out this investigation, building professionals in clients’ organisations, contracting and consultancy organisations within the industry were asked to respond to the Ethics Position Questionnaire (EPQ designed by Forsyth in order to determine their idealism and relativism level. Subsequently, they were classified into one of four groups, representing different ethical ideologies. The result indicates that the dominant ethical ideology of building industry professionals is situationism. The study predicts that the attitude of building industry professionals in practice, given the current socio-political and economic situation of Nigeria would possibly be unethical because of the extreme influence situational factors have on their behaviour. This finding is a bold step and necessary benchmark for resolving ethical issues within the industry and should be of interest to policy makers. It is also useful for intra professional ethical comparison.

  4. Study of Customer Satisfaction with Living Conditions in New Apartment Buildings

    Directory of Open Access Journals (Sweden)

    Lepkova Natalija

    2016-09-01

    Full Text Available The article aims to analyze the Lithuanian housing market and to look into the satisfaction of people with living conditions in new apartment buildings on this market. The article presents the concept of customer satisfaction in construction and the criteria that define the quality of dwellings; the benefits, consequences, merits and demerits of the assessment of customer satisfaction are also named. A survey of customer satisfaction helped to evaluate the quality of dwellings according to their technical and functional parameters, as well as the degree of cooperation between customers and contractors/builders. The customer satisfaction index (CSI and the degree of loyalty were calculated, and then a customer satisfaction matrix was built up.

  5. Mapping the Capacity Building Process of a Corporate Social ...

    African Journals Online (AJOL)

    The result of data analysis shows that, 75% of the respondents indicated they needed practical capacity building for effective project management and sustainability. The findings support a dire need for participatory evaluation on strategies towards the improvement of capacity building process service delivery. Key Words: ...

  6. Acute Chemical Incidents With Injured First Responders, 2002-2012.

    Science.gov (United States)

    Melnikova, Natalia; Wu, Jennifer; Yang, Alice; Orr, Maureen

    2018-04-01

    IntroductionFirst responders, including firefighters, police officers, emergency medical services, and company emergency response team members, have dangerous jobs that can bring them in contact with hazardous chemicals among other dangers. Limited information is available on responder injuries that occur during hazardous chemical incidents. We analyzed 2002-2012 data on acute chemical incidents with injured responders from 2 Agency for Toxic Substances and Disease Registry chemical incident surveillance programs. To learn more about such injuries, we performed descriptive analysis and looked for trends. The percentage of responders among all injured people in chemical incidents has not changed over the years. Firefighters were the most frequently injured group of responders, followed by police officers. Respiratory system problems were the most often reported injury, and the respiratory irritants, ammonia, methamphetamine-related chemicals, and carbon monoxide were the chemicals more often associated with injuries. Most of the incidents with responder injuries were caused by human error or equipment failure. Firefighters wore personal protective equipment (PPE) most frequently and police officers did so rarely. Police officers' injuries were mostly associated with exposure to ammonia and methamphetamine-related chemicals. Most responders did not receive basic awareness-level hazardous material training. All responders should have at least basic awareness-level hazardous material training to recognize and avoid exposure. Research on improving firefighter PPE should continue. (Disaster Med Public Health Preparedness. 2018;12:211-221).

  7. Drug use among complete responders, partial responders and non-responders in a longitudinal survey of nonagenarians

    DEFF Research Database (Denmark)

    Wastesson, Jonas W; Rasmussen, Lotte; Oksuzyan, Anna

    2017-01-01

    PURPOSE: In observational studies, non-response can limit representativity and introduce bias. We aimed to investigate the longitudinal changes in the number of used drugs among complete responders, partial responders, and non-responders in a whole birth cohort of Danish nonagenarians participati...

  8. Cost-optimal levels of minimum energy performance requirements in the Danish Building Regulations

    Energy Technology Data Exchange (ETDEWEB)

    Aggerholm, S.

    2013-09-15

    improvement of existing building both in the case of major renovation and in the case of several less comprehensive renovations. The component requirements are in nearly all cases tighter than the point of cost optimal. It could be considered to tighten the requirement to insulation in open loft spaces where it is more beneficial to add a significant higher thickness of insulation compared to insulation in other roof constructions e.g. parallel roof. It could also be a possibility in relation to the insulation of the basement slap, but it has to be combined with an analysis of the moister conditions in the unheated basement. In relation to major renovation the gap between requirements and cost optimality is very small. The reason is probably that the Danish energy requirements to existing building in itself includes a rentability factor provision that brings the requirements very close to cost optimality. The tightening of the requirements to windows in 2015 and 2020 seems to move the requirements to existing buildings beyond cost optimality. Probably this will be solved by the change in price for efficient windows. (LN)

  9. Risk Factors in Heating, Ventilating, and Air-Conditioning Systemsfor Occupant Symptoms in U.S. Office Buildings: the EPA BASE Study

    Energy Technology Data Exchange (ETDEWEB)

    Mendell, M.J.; Lei-Gomez, Q.; Mirer, A.; Seppanen, O.; Brunner, G.

    2006-10-01

    Nonspecific building-related symptoms among occupants of modern office buildings worldwide are common and may be associated with important reductions in work performance, but their etiology remains uncertain. Characteristics of heating, ventilating, and air-conditioning (HVAC) systems in office buildings that increase risk of indoor contaminants or reduce effectiveness of ventilation may cause adverse exposures and subsequent increase in these symptoms among occupants. We analyzed data collected by the U.S. EPA from a representative sample of 100 large U.S. office buildings--the Building Assessment and Survey Evaluation (BASE) study--using multivariate logistic regression models with generalized estimating equations adjusted for potential personal and building confounders. We estimated odds ratios (ORs) and 95% confidence intervals (CIs) for associations between seven building-related symptom outcomes and selected HVAC system characteristics. Among factors of HVAC design or configuration: Outdoor air intakes less than 60 m above the ground were associated with approximately doubled odds of most symptoms assessed. Sealed (non-operable) windows were associated with increases in skin and eye symptoms (ORs= 1.9, 1.3, respectively). Outdoor air intake without an intake fan was associated with an increase in eye symptoms (OR=1.7). Local cooling coils were associated with increased headache (OR=1.5). Among factors of HVAC condition, maintenance, or operation: the presence of humidification systems in good condition was associated with an increase in headache (OR=1.4), whereas the presence of humidification systems in poor condition was associated with increases in fatigue/difficulty concentrating, as well as upper respiratory symptoms (ORs=1.8, 1.5). No regularly scheduled inspections for HVAC components was associated with increased eye symptoms, cough and upper respiratory symptoms (ORs=2.2, 1.6, 1.5). Less frequent cleaning of cooling coils or drip pans was associated

  10. Diagnostics of the illuminance levels of building of EIE complying with the Standard INTECO

    International Nuclear Information System (INIS)

    Cubero Hernandez, Wargner

    2013-01-01

    An analysis detailed is performed in spaces comprising the Edificio de Ingenieria Electrica; the designs of lighting aforetime were made without use of standards or scientifically proven methods, could be that this building be the case. The Standard IESNA is considered both to perform the analysis, which has set the standard to perform the respective measurements of the areas indicated in the building. Also, the standard INTECO is used, this makes mention of the minimum values recommended that each space should have analyzed, and these values meet the visual needs that are necessary for visual comfort. The measurements are performed using the illuminance meter and where it was considered the proper distribution of luminaires; the simulation of the spaces without meet the minimum values established by the standard INTECO; tabulation and comparison between the values obtained; have been the three parts of the project. Not all areas could be measured. Deficiencies are found in most levels comprising the building; if there are spaces that have meet the values specified in the standard, with good maintenance of the lights and plan optimal replacement of damaged fittings, will do even more to improve lighting levels that present in the building. Technology installed at present has been not the best, from the point of view of efficiency, since a larger electric power flows without representing a better light intensity, otherwise the recommendation given to venture into the LED technology. (author) [es

  11. On-line survey of professional stakeholder perceptions of energy labelling for buildings : final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-11-15

    This paper presented the results of a survey conducted to examine stakeholder responses to energy labelling for buildings. Stakeholders were also asked to respond to a first draft energy label created to provide a national template for energy consumption in commercial, institutional, and residential buildings. A total of 1943 buildings sector stakeholders were consulted to help identify improvements to the labelling system. Over 88 per cent of all respondents supported the idea of introducing an energy labelling system for buildings. Engineers, technologists, and energy consultants strongly supported the system, while real estate appraisers and building and maintenance managers were less supportive of the idea. A clear majority supported the idea of a mandatory labelling system. The majority of stakeholders agreed that the system would serve to aid valuators, buyers, and tenants in making energy efficient purchases, and serve as a useful benchmarking tool. Results of the survey also showed that the majority of respondents were willing to incur administrative fees related to the labelling system, and that the label's benefits would be maximized through the use of an expiry date. Approximately 71 per cent of respondents thought that the label should be linked to financial incentives. All stakeholders were shown to have a positive impression of the draft label. 15 tabs.

  12. Career satisfaction level, mental distress, and gender differences in working conditions among Japanese obstetricians and gynecologists.

    Science.gov (United States)

    Sugiura-Ogasawara, Mayumi; Suzuki, Sadao; Kitazawa, Masafumi; Kuwae, Chizuko; Sawa, Rintaro; Shimizu, Yukiko; Takeshita, Toshiyuki; Yoshimura, Yasunori

    2012-03-01

    Career satisfaction level, degree of mental distress associated with certain work-related factors, and demographics were examined for the first time in obstetricians and gynecologists in Japan. Associations between the score on Kessler 6 screening scale, or the job satisfaction level, and the scores on the job content questionnaire, Social Support Questionnaire (SSQ), working conditions and demographics were examined in 1301 members of the Japan Society of Obstetrics and Gynecology. 8.4% of respondents were speculated to suffer from depression or anxiety disorder. Multivariate linear regression analysis identified a heavier workload, less personal control, lower satisfaction on the SSQ, and longer working hours as being independent risk factors for mental distress. Careful monitoring of the mental state is necessary for obstetricians and gynecologists with lower incomes, heavier workloads, lower degrees of personal control, and lower satisfaction scores on the SSQ. © 2012 The Authors. Journal of Obstetrics and Gynaecology Research © 2012 Japan Society of Obstetrics and Gynecology.

  13. SOLAR SYSTEMS FOR RESIDENTIAL BUILDINGS IN ACCORDANCE WITH OPERATING CONDITIONS OF THE REPUBLIC OF BELARUS

    Directory of Open Access Journals (Sweden)

    M. A. Rutkowski

    2017-01-01

    Full Text Available Solar systems are actively applied for heat supply of buildings in Europe. Usage of solar energy for heat supply of residential buildings is considered as rather efficient for the Republic of Belarus because total amount of direct and scattered solar radiation entering horizontal surface is equivalent to an average European index for the climate of Belarus. The paper analyzes an existing dependence on determination of solar system efficiency and proposes an amended formula for calculations while designing solar consumption systems and its legitimacy has been experimentally proved. A scheme of an experimental unit with explanations and a brief description for execution of experiments and main results of the completed investigations have been presented in the paper. Experiments have been carried out for solar systems with natural and forced coolant circulation. Attention has been paid to obtaining maximum possible temperature potential of the coolant during operation of the solar system within periods of high and low solar radiation intensity. Recommendations on practical application of solar systems for multi-storey residential buildings houses and mansion-type houses have been given in the paper. The paper presents technological principles of constructing “passive” solar heating devices. A comparison of traditionally applied and proposed alternative solar systems has been made for operational conditions in Belarus. The paper proposes a solar system for hot water supply of multi-storey buildings. The proposed system has found its first realization in the Republic while designing and constructing an energy-efficient demonstration 10-storey residential building in Mogilev within the framework of the UN Development Program project and Global Environment Fund “Improvement of energy efficiency for residential buildings in the Republic of Belarus”

  14. Actual building energy use patterns and their implications for predictive modeling

    International Nuclear Information System (INIS)

    Heidarinejad, Mohammad; Cedeño-Laurent, Jose G.; Wentz, Joshua R.; Rekstad, Nicholas M.; Spengler, John D.; Srebric, Jelena

    2017-01-01

    Highlights: • Developed three building categories based on energy use patterns of campus buildings. • Evaluated implication of temporal energy data granularity on predictive modeling. • Demonstrated importance of monitoring daily chilled water consumption. • Identified interval electricity data as an indicator of building operation schedules. • Demonstrated a calibration process for energy modeling of a campus building. - Abstract: The main goal of this study is to understand the patterns in which commercial buildings consume energy, rather than evaluating building energy use based on aggregate utility bills typically linked to building principal tenant activity or occupancy type. The energy consumption patterns define buildings as externally-load, internally-load, or mixed-load dominated buildings. Penn State and Harvard campuses serve as case studies for this particular research project. The buildings in these two campuses use steam, chilled water, and electricity as energy commodities and maintain databases of different resolutions to include minute, hourly, daily, and monthly data instances depending on the commodity and available data acquisition system. The results of this study show monthly steam consumption directly correlates to outdoor environmental conditions for 88% of the studied buildings, while chilled water consumption has negligible correlation to the outdoor environmental conditions. Thus, in terms of monthly chilled water consumption, 86% of buildings are internally-load and mixed-load dominated, respectively. Chilled water consumption is better suited for the daily analyses compared to the monthly and hourly analyses. While the influence of building operation schedules affects the analyses at the hourly level, the monthly chilled water consumptions are not good indicators of the building energy consumption patterns. Electricity consumption at the monthly (or seasonal) level can support the building energy simulation tools for the

  15. Mobile augmented reality in support of building damage and safety assessment

    Science.gov (United States)

    Kim, W.; Kerle, N.; Gerke, M.

    2016-02-01

    Rapid and accurate assessment of the state of buildings in the aftermath of a disaster event is critical for an effective and timely response. For rapid damage assessment of buildings, the utility of remote sensing (RS) technology has been widely researched, with focus on a range of platforms and sensors. However, RS-based approaches still have limitations to assess structural integrity and the specific damage status of individual buildings. Structural integrity refers to the ability of a building to hold the entire structure. Consequently, ground-based assessment conducted by structural engineers and first responders is still required. This paper demonstrates the concept of mobile augmented reality (mAR) to improve performance of building damage and safety assessment in situ. Mobile AR provides a means to superimpose various types of reference or pre-disaster information (virtual data) on actual post-disaster building data (real buildings). To adopt mobile AR, this study defines a conceptual framework based on the level of complexity (LOC). The framework consists of four LOCs, and for each of these, the data types, required processing steps, AR implementation and use for damage assessment are described. Based on this conceptualization we demonstrate prototypes of mAR for both indoor and outdoor purposes. Finally, we conduct a user evaluation of the prototypes to validate the mAR approach for building damage and safety assessment.

  16. Energy conservation according to the building codes of the National Board of Housing, Building and Planning; Energihushaallning enligt Boverkets byggregler

    Energy Technology Data Exchange (ETDEWEB)

    2009-10-15

    To comply with international and national targets for energy use, the National Board has adopted rules setting the levels to be met in order to conserve energy in buildings. The rules for buildings are shown in Boverkets building regulations (BBR). The BBR lists comprehensive requirements in order to ensure that a building must not use more than a certain number of kilowatt hours per square meter and year. There are more detailed requirements for thermal insulation, heating, cooling and air conditioning installations, efficient use of electricity and installation of metering systems for monitoring of building energy. The latest version of the BBR came into force on February 1, 2009 and has more stringent requirements for the buildings heated by electricity or comfort cooling powered by electricity. This handbook presents comments and answers to questions about the new rules for energy conservation. It replaces our previous handbook 'Thermal calculations'

  17. Level 3 Baseline Risk Assessment for Building 3515 at Oak Ridge National Lab., Oak Ridge, TN

    Energy Technology Data Exchange (ETDEWEB)

    Wollert, D.A.; Cretella, F.M.; Golden, K.M. [Univ. of Tennessee, Knoxville, TN (United States)] [and others

    1995-08-01

    The baseline risk assessment for the Fission Product Pilot Plant (Building 3515) at the Oak Ridge National laboratory (ORNL) provides the Decontamination and Decommissioning (D&D) Program at ORNL and Building 3515 project managers with information concerning the results of the Level 3 baseline risk assessment performed for this building. The document was prepared under Work Breakdown Structure 1.4.12.6.2.01 (Activity Data Sheet 3701, Facilities D&D) and includes information on the potential long-term impacts to human health and the environment if no action is taken to remediate Building 3515. Information provided in this document forms the basis for the development of remedial alternatives and the no-action risk portion of the Engineering Evaluation/Cost Analysis report.

  18. Level 3 Baseline Risk Assessment for Building 3515 at Oak Ridge National Lab., Oak Ridge, TN

    International Nuclear Information System (INIS)

    Wollert, D.A.; Cretella, F.M.; Golden, K.M.

    1995-08-01

    The baseline risk assessment for the Fission Product Pilot Plant (Building 3515) at the Oak Ridge National laboratory (ORNL) provides the Decontamination and Decommissioning (D ampersand D) Program at ORNL and Building 3515 project managers with information concerning the results of the Level 3 baseline risk assessment performed for this building. The document was prepared under Work Breakdown Structure 1.4.12.6.2.01 (Activity Data Sheet 3701, Facilities D ampersand D) and includes information on the potential long-term impacts to human health and the environment if no action is taken to remediate Building 3515. Information provided in this document forms the basis for the development of remedial alternatives and the no-action risk portion of the Engineering Evaluation/Cost Analysis report

  19. 33 CFR 101.200 - MARSEC Levels.

    Science.gov (United States)

    2010-07-01

    ..., vessel, and facility shall operate at MARSEC Level 1. (c) The Commandant will set the MARSEC Level consistent with the equivalent Homeland Security Advisory System (HSAS) Threat Condition and that Threat... national transportation system. Ports, under direction of the local COTP, will respond to changes in the...

  20. Roadmap-Based Level Clearing of Buildings

    KAUST Repository

    Rodriguez, Samuel; Amato, Nancy M.

    2011-01-01

    In this paper we describe a roadmap-based approach for a multi-agent search strategy to clear a building or multi-story environment. This approach utilizes an encoding of the environment in the form of a graph (roadmap) that is used to encode

  1. Determining the Efficiency of Adaptation of Foreign Economic Activity of Machine-Building Enterprises in Conditions of Deepening the European Integration Process of Ukraine

    Directory of Open Access Journals (Sweden)

    Semeniuk Iryna Yu.

    2018-02-01

    Full Text Available The article determines that introduction and implementation of the mechanism for foreign economic adaptation of machine-building enterprises to the conditions of the European integration processes requires constant monitoring of the processes of export-import operations and the adaptation activities to identify current problems and avoid risks. It has been found that one of the monitoring instruments is the system of indicators, which provides to evaluate the efficiency of use of the mechanism for foreign economic adaptation of a machine-building enterprise by comparing the values of the obtained indicators after accomplishing adaptation changes with the values of the indicators of previous periods. It is suggested to determine efficiency of adaptation of foreign economic activity of machine-building enterprises to conditions of deepening of the European integration process of Ukraine by means of: index of change of volume of exported production of a machine-building enterprise to the EU countries; weighted average of the change in the share of the European market, which is covered by the enterprise’s products; indicator of efficiency of exports of production of a machine-building enterprise to the European Union countries; indicator of the index of changes in the volume of permanent orders from European partners; integral indicator of efficiency of use of adaptive potential of a machine-building enterprise in conditions of integration processes.

  2. Assessment of the Fire Risk Levels in an Office Building and a Nightclub with Prescriptive Designs

    DEFF Research Database (Denmark)

    Yilmaz, D.; Steffensen, F.B.; Jomaas, Grunde

    2014-01-01

    A comparison of the risk level of an office building and a nightclub with code compliant prescriptive designs was conducted in order to evaluate whether an uniform safety level of the two occupancy types can be established. A risk assessment method using Monte Carlo simulations and 1- and 2-zone......-movement time and the movement time were adjusted for the required safe egress time (RSET) of the nightclub. The number of simulations required in order to obtain reliable results was considered sufficient at 20,000. The comparison of the risk profiles of the nightclub and the office building showed significant...... difference in risk levels, with that of the nightclub being substantially higher. The higher risk level in the nightclub is caused by a relatively fast mean value of the fire growth rate and the high number of occupants. Hence, the requirements in the prescriptive code do not ensure a similar safety level...

  3. Assessment of Technogenic Accident Risk of Industrial Building Structures

    Science.gov (United States)

    Baiburin, D. A.; Baiburin, A. Kh

    2017-11-01

    A methodology for assessing the risk of an industrial building accident was developed taking into account the damage caused by various localization of collapse. Before the beginning of the survey of a facility technical condition, groups including the same type of building structures are selected. Further, assessment is made for the reduction in their load-carrying capacity from the strength and stability conditions taking into account defects. The characteristics of the influence of defects and structural damage on a building safety is the degree of compliance with the standards expressed by the reliability level. Reliability levels assignment is carried out on the basis of calculations, operating experience and inspection of a particular type of structure according to the formalized rules. The risk of collapse according to a separate scenario is calculated for structures that are capable and incapable of causing a progressive ossification. The results of the technique application are based on the analysis of the accident risk at the welding shop “Vysota (Height) 239” of the Chelyabinsk Pipe Rolling Plant.

  4. Auditable safety analysis: High Radiation Level Chemical Development Facility (Buildings 4507 and 4556), Oak Ridge National Laboratory, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    Platfoot, J.H.

    1998-07-01

    The High-Radiation-Level Chemical Development Facility includes Buildings 4507 and 4556. Building 4507, located immediately to the west of Building 4500N and to the south of Building 4505, is a doubly contained three-level structure constructed in 1957. The most recent use of the facility was for recovery of multi-gram quantities of 244 Cm during the early 1970s and for Liquid Metal Fast Breeder Reactor (LMFBR) fuel studies in the late 1970s. It has remained in safe standby since 1980. Building 4556 is a below-grade filter pit located to the southwest of Building 4507 and was constructed in 1972. Ventilation from the cells in Building 4507 is passed through high-efficiency particulate air (HEPA) filtration in this building prior to being exhausted to the Building 3039 stack system. This building remains in operation to support ventilation requirements for Building 4507. This Auditable Safety Analysis (ASA) was developed in accordance with the requirements in Energy Systems Program Description FS-103PD, Safety Documentation, Revision 1. This ASA identifies and screens all hazards associated with Buildings 4507 and 4556. The only hazard not screened out and requiring further analysis following the initial screening process is radioactive material in the form of surface contamination. The results of this ASA indicate that the hazards associated with Buildings 4507 and 4556 do not pose a significant threat to workers, the public, or the environment

  5. Implementation and integration in the L3 experimentation of a level-2 trigger with event building, based on C104 data driven cross-bar switches and on T9000 transputers

    International Nuclear Information System (INIS)

    Masserot, A.

    1995-01-01

    This thesis describes the new level-2 trigger system. It has been developed to fit the L3 requirements induced by the LEP phase 2 conditions. At each beam crossing, the system memorizes the trigger data, builds-up the events selected by the level-1 hard-wired processors and finally rejects on-line the background identified by algorithms coded in Fortran. Based on T9000 Transputers and on C104 data driven cross-bar switches, the system uses prototypes designed by INMOS/SGS THOMSON for parallel processing applications. Emphasis is set on a new event building technic, on its integration in L3 and on performance. (author). 38 refs., 68 figs., 36 tabs

  6. Modeling of an Air Conditioning System with Geothermal Heat Pump for a Residential Building

    Directory of Open Access Journals (Sweden)

    Silvia Cocchi

    2013-01-01

    Full Text Available The need to address climate change caused by greenhouse gas emissions attaches great importance to research aimed at using renewable energy. Geothermal energy is an interesting alternative concerning the production of energy for air conditioning of buildings (heating and cooling, through the use of geothermal heat pumps. In this work a model has been developed in order to simulate an air conditioning system with geothermal heat pump. A ground source heat pump (GSHP uses the shallow ground as a source of heat, thus taking advantage of its seasonally moderate temperatures. GSHP must be coupled with geothermal exchangers. The model leads to design optimization of geothermal heat exchangers and to verify the operation of the geothermal plant.

  7. Building-level analyses to prospectively detect influenza outbreaks in long-term care facilities: New York City, 2013-2014.

    Science.gov (United States)

    Levin-Rector, Alison; Nivin, Beth; Yeung, Alice; Fine, Annie D; Greene, Sharon K

    2015-08-01

    Timely outbreak detection is necessary to successfully control influenza in long-term care facilities (LTCFs) and other institutions. To supplement nosocomial outbreak reports, calls from infection control staff, and active laboratory surveillance, the New York City (NYC) Department of Health and Mental Hygiene implemented an automated building-level analysis to proactively identify LTCFs with laboratory-confirmed influenza activity. Geocoded addresses of LTCFs in NYC were compared with geocoded residential addresses for all case-patients with laboratory-confirmed influenza reported through passive surveillance. An automated daily analysis used the geocoded building identification number, approximate text matching, and key-word searches to identify influenza in residents of LTCFs for review and follow-up by surveillance coordinators. Our aim was to determine whether the building analysis improved prospective outbreak detection during the 2013-2014 influenza season. Of 119 outbreaks identified in LTCFs, 109 (92%) were ever detected by the building analysis, and 55 (46%) were first detected by the building analysis. Of the 5,953 LTCF staff and residents who received antiviral prophylaxis during the 2013-2014 season, 929 (16%) were at LTCFs where outbreaks were initially detected by the building analysis. A novel building-level analysis improved influenza outbreak identification in LTCFs in NYC, prompting timely infection control measures. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  8. Method of reducing radon levels in buildings

    International Nuclear Information System (INIS)

    Khajdarov, R.A.; Gapurova, O.U.; Khajdarov, R.R.

    2004-01-01

    Radon concentration can be reduced by using polymeric compositions which fill pores inside building materials and decrease the coefficient of permeation of radon atoms and water molecules in building materials (concrete, gypsum, etc.). Polymeric silico-organic compounds were investigated and selected as the chemicals to prevent radon seeping indoors. Gas (air, Ar, 222 Rn, H 2 O) permeability of concrete and gypsum after treatment with chemicals was examined. The effect of the cement and sand types, preliminary treatment with various chemicals, type of the polymeric silico-organic compounds, time between treatments, moisture of concrete, time between the preparation of chemicals and the treatment of concrete (ageing of chemicals), time between the treatment of concrete and testing (ageing of treated concrete) were examined. Surfaces of the samples were treated by spraying. The experiments gave evidence that the chosen method of treatment of the construction materials allows reducing the coefficient of gas permeability in 200 - 400 times. Treatment of the floor, walls and ceiling of the basement of 5 buildings reduced the radon concentration in the premises of the first floor from 400-600 Bq/m 3 to the background value of 17-20 Bq/m 3

  9. Condition-specific RNA editing in the coral symbiont Symbiodinium microadriaticum

    KAUST Repository

    Liew, Yi Jin

    2017-03-01

    RNA editing is a rare post-transcriptional event that provides cells with an additional level of gene expression regulation. It has been implicated in various processes including adaptation, viral defence and RNA interference; however, its potential role as a mechanism in acclimatization has just recently been recognised. Here, we show that RNA editing occurs in 1.6% of all nuclear-encoded genes of Symbiodinium microadriaticum, a dinoflagellate symbiont of reef-building corals. All base-substitution edit types were present, and statistically significant motifs were associated with three edit types. Strikingly, a subset of genes exhibited condition-specific editing patterns in response to different stressors that resulted in significant increases of non-synonymous changes. We posit that this previously unrecognised mechanism extends this organism’s capability to respond to stress beyond what is encoded by the genome. This in turn may provide further acclimatization capacity to these organisms, and by extension, their coral hosts.

  10. Condition-specific RNA editing in the coral symbiont Symbiodinium microadriaticum

    KAUST Repository

    Liew, Yi Jin; Li, Yong; Baumgarten, Sebastian; Voolstra, Christian R.; Aranda, Manuel

    2017-01-01

    RNA editing is a rare post-transcriptional event that provides cells with an additional level of gene expression regulation. It has been implicated in various processes including adaptation, viral defence and RNA interference; however, its potential role as a mechanism in acclimatization has just recently been recognised. Here, we show that RNA editing occurs in 1.6% of all nuclear-encoded genes of Symbiodinium microadriaticum, a dinoflagellate symbiont of reef-building corals. All base-substitution edit types were present, and statistically significant motifs were associated with three edit types. Strikingly, a subset of genes exhibited condition-specific editing patterns in response to different stressors that resulted in significant increases of non-synonymous changes. We posit that this previously unrecognised mechanism extends this organism’s capability to respond to stress beyond what is encoded by the genome. This in turn may provide further acclimatization capacity to these organisms, and by extension, their coral hosts.

  11. Energy Savings Potential and Research, Development, & Demonstration Opportunities for Residential Building Heating, Ventilation, and Air Conditioning Systems

    Energy Technology Data Exchange (ETDEWEB)

    Goetzler, William [Navigant Consulting, Inc., Burlington, MA (United States); Zogg, Robert [Navigant Consulting, Inc., Burlington, MA (United States); Young, Jim [Navigant Consulting, Inc., Burlington, MA (United States); Schmidt, Justin [Navigant Consulting, Inc., Burlington, MA (United States)

    2012-10-01

    This report is an assessment of 135 different heating, ventilation, and air-conditioning (HVAC) technologies for U.S. residential buildings to identify and provide analysis on 19 priority technology options in various stages of development. The analyses include an estimation of technical energy-savings potential, descriptions of technical maturity, descriptions of non-energy benefits, descriptions of current barriers for market adoption, and descriptions of the technology's applicability to different building or HVAC equipment types. From these technology descriptions, are suggestions for potential research, development and demonstration (RD&D) initiatives that would support further development of the priority technology options.

  12. Energy Savings Potential and Research, Development, & Demonstration Opportunities for Commercial Building Heating, Ventilation, and Air Conditioning Systems

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2011-09-01

    This report covers an assessment of 182 different heating, ventilation, and air-conditioning (HVAC) technologies for U.S. commercial buildings to identify and provide analysis on 17 priority technology options in various stages of development. The analyses include an estimation of technical energy-savings potential, description of technical maturity, description of non-energy benefits, description of current barriers for market adoption, and description of the technology’s applicability to different building or HVAC equipment types. From these technology descriptions, are suggestions for potential research, development and demonstration (RD&D) initiatives that would support further development of the priority technology options.

  13. Lay First Responder Training in Eastern Uganda: Leveraging Transportation Infrastructure to Build an Effective Prehospital Emergency Care Training Program.

    Science.gov (United States)

    Delaney, Peter G; Bamuleke, Richard; Lee, Yang Jae

    2018-01-18

    Though road traffic injuries (RTIs) are a major cause of mortality in East Africa, few countries have emergency medical services. The aim was to create a sustainable and efficient prehospital lay first responder program, creating a system with lay first responders spread through the 53 motorcycle taxi stages of Iganga Municipality. One hundred and fifty-four motorcycle taxi riders were taught a first aid curriculum in partnership with a local Red Cross first aid trainer and provided with a first aid kit following WHO guidelines for basic first aid. Pre- and post-survey tests measured first aid knowledge improvement over the course. Post-implementation incident report forms were collected from lay first responders after each patient encounter over 6 months. Follow-up interviews were conducted with 110 of 154 trainees, 9 months post-training. Improvement was measured across all five major first aid categories: bleeding control (56.9 vs. 79.7%), scene management (37.6 vs. 59.5%), airway and breathing (43.4 vs. 51.6%), recovery position (13.1 vs. 43.4%), and victim transport (88.2 vs. 94.3%). From the incident report findings, first responders treated 250 victims (82.8% RTI related) and encountered 24 deaths (9.6% of victims). Of the first aid skills, bleeding control and bandaging was used most often (55.2% of encounters). Lay first responders provided transport in 48.3% of encounters. Of 110 lay first responders surveyed, 70 of 76 who had used at least one skill felt "confident" in the care they provided. A prehospital care system composed of lay first responders can be developed leveraging existing transport organizations, offering a scalable alternative for LMICs, demonstrating usefulness in practice and measurable educational improvements in trauma skills for non-clinical lay responders.

  14. Responding to excessive alcohol consumption in third-level (REACT): a study protocol.

    Science.gov (United States)

    Davoren, Martin P; Calnan, Susan; Mulcahy, Judith; Lynch, Emily; Perry, Ivan J; Byrne, Michael

    2018-05-11

    Problem alcohol use is an ongoing, worldwide phenomenon of considerable concern. Throughout the past 20 years, national policies have noted the importance of students when tackling alcohol consumption. Considering alcohol is a multifaceted issue, a multi-component response is required to combat its excessive use. This protocol sets out the approach used for developing, implementing and evaluating the REACT (Responding to Excessive Alcohol Consumption in Third-level) Programme. This evaluation will provide the evidence base for programme development, implementation and improvement. Stage one involved defining the multi-component intervention. This was developed following a systematic review of existing literature and a Delphi-consensus workshop involving university students, staff and relevant stakeholders. Following this, the programme is being implemented across the Higher Education sector in Ireland. A number of Higher Education Institutes have declined the invitation to participate in the programme. These institutions will act as control sites. Each intervention site will have a steering committee whose membership will include a mix of students and academic and student service staff. This steering committee will report to the REACT research team on the implementation of mandatory and optional action points at local sites. An online cross-sectional study at baseline and two-years post intervention will be utilised to determine the impact of the REACT programme. The impact assessment will focus on (1) whether the intervention has reduced alcohol consumption among third-level students (2); whether the programme altered students attitudes toward alcohol and (3) whether the programme has decreased the second-hand effects associated with excessive consumption. Finally, qualitative research will focus on factors influencing the take-up and implementation of this programme as well as students' views on the initiative. Alcohol consumption has remained on the policy

  15. Measures taken by the building authorities in order to reduce radiation risks in buildings

    International Nuclear Information System (INIS)

    Tell, Wilhelm

    1980-01-01

    The Swedish radon commission has recommended that the risk of radiation and radon emission from the ground be considered when planning for new settlements, building materials with high radioactivity not be allowed for new buildings, and existing buildings with high levels of radioactivity be traced and improved. Maps of gamma radiation from the ground are being worked out showing areas with levels higher than 30 μR/h. Within such areas buildings should be planned taking the ultimate limits for new buildings into account. Building permits are granted for construction of new structures or extensive renovations if it can be shown that radiation levels within the buildings will be within legal limits: 70 Bq/m 3 for new buildings and 200 Bq/m 3 for existing ones. The radon commission has suggested that buildings with a radon daughter concentration exceeding 400 Bq/m 3 should be found and levels reduced to 200 Bq/m 3

  16. Development of knowledge building program concerning about high-level radioactive waste disposal

    International Nuclear Information System (INIS)

    Kimura, Hiroshi; Yamada, Kazuhiro; Takase, Hiroyasu

    2005-01-01

    Acquirement of knowledge about the high-level radioactive waste (HLW) disposal is one of the important factors for public to determine the social acceptance of HLW disposal. However in Japan, public do not have knowledge about HLW and its disposal sufficiently. In this work, we developed the knowledge building program concerning about HLW disposal based on Nonaka, and Takeuchi's SECI spiral model in knowledge management, and carried to the experiment on this program. In the results, we found that the participants' knowledge about the HLW disposal increased and changed from misunderstanding' or 'assuming' to 'facts' or 'consideration' through this experimental program. These results said that the experimental program leads participants to have higher quality of knowledge about the HLW disposal. In consequence, this knowledge building program may be effective in the acquirement of high quality knowledge. (author)

  17. Responding to Mechanical Antigravity

    Science.gov (United States)

    Millis, Marc G.; Thomas, Nicholas E.

    2006-01-01

    Based on the experiences of the NASA Breakthrough Propulsion Physics Project, suggestions are offered for constructively responding to proposals that purport breakthrough propulsion using mechanical devices. Because of the relatively large number of unsolicited submissions received (about 1 per workday) and because many of these involve similar concepts, this report is offered to help the would-be submitters make genuine progress as well as to help reviewers respond to such submissions. Devices that use oscillating masses or gyroscope falsely appear to create net thrust through differential friction or by misinterpreting torques as linear forces. To cover both the possibility of an errant claim and a genuine discovery, reviews should require that submitters meet minimal thresholds of proof before engaging in further correspondence; such as achieving sustained deflection of a level-platform pendulum in the case of mechanical thrusters.

  18. Treatment and conditioning of low-level radioactive waste in Belgium: initial operating results of the Cilva facility

    International Nuclear Information System (INIS)

    Monsch, O.; Renard, C.; Deckers, J.; Luycx, P.

    1995-01-01

    The Belgian National Radioactive Waste and Enriched Fissile Material Agency (ONDRAF), which is responsible for the management of all radioactive waste in Belgium, recently decided to commission the CILVA facility. Operation of this facility, which comprises a number of units for the treatment of low-level radwaste, has been contracted to ONDRAF's Belgoprocess subsidiary based at the Dessel site. A consortium comprising SGN and Fabricom was in charge of building the CILVA facility's waste preparation and conditioning (concrete solidification) units. The concrete solidification processes, which were devised and developed by SGN, have been qualified to secure ONDRAF certification of the process and the facility. This enabled active commissioning of the waste conditioning unit in mid-August 1994. Active commissioning of the waste preparation unit was carried out in several stages up to the beginning of 1995 in accordance with operating requirements. Initial operating results of the two units are presented. (author)

  19. Mischievous responding in Internet Gaming Disorder research.

    Science.gov (United States)

    Przybylski, Andrew K

    2016-01-01

    The most recent update to the American Psychiatric Association's (APA) Diagnostic and Statistical Manual of Mental Disorders (DSM-5) included Internet Gaming Disorder as a new potential psychiatric condition that merited further scientific study. The present research was conducted in response to the APA Substance-Related Disorders Working Group's research call to estimate the extent to which mischievous responding-a known problematic pattern of participant self-report responding in questionnaires-is relevant to Internet Gaming Disorder research. In line with a registered sampling and analysis plan, findings from two studies (n tot = 11,908) provide clear evidence that mischievous responding is positively associated with the number of Internet Gaming Disorder indicators participants report. Results are discussed in the context of ongoing problem gaming research and the discussion provides recommendations for improving the quality of scientific practice in this area.

  20. Event-building and PC farm based level-3 trigger at the CDF experiment

    CERN Document Server

    Anikeev, K; Furic, I K; Holmgren, D; Korn, A J; Kravchenko, I V; Mulhearn, M; Ngan, P; Paus, C; Rakitine, A; Rechenmacher, R; Shah, T; Sphicas, Paris; Sumorok, K; Tether, S; Tseng, J

    2000-01-01

    In the technical design report the event building process at Fermilab's CDF experiment is required to function at an event rate of 300 events/sec. The events are expected to have an average size of 150 kBytes (kB) and are assembled from fragments of 16 readout locations. The fragment size from the different locations varies between 12 kB and 16 kB. Once the events are assembled they are fed into the Level-3 trigger which is based on processors running programs to filter events using the full event information. Computing power on the order of a second on a Pentium II processor is required per event. The architecture design is driven by the cost and is therefore based on commodity components: VME processor modules running VxWorks for the readout, an ATM switch for the event building, and Pentium PCs running Linux as an operation system for the Level-3 event processing. Pentium PCs are also used to receive events from the ATM switch and further distribute them to the processing nodes over multiple 100 Mbps Ether...

  1. Indoor radon problem in energy efficient multi-storey buildings.

    Science.gov (United States)

    Yarmoshenko, I V; Vasilyev, A V; Onishchenko, A D; Kiselev, S M; Zhukovsky, M V

    2014-07-01

    Modern energy-efficient architectural solutions and building construction technologies such as monolithic concrete structures in combination with effective insulation reduce air permeability of building envelope. As a result, air exchange rate is significantly reduced and conditions for increased radon accumulation in indoor air are created. Based on radon survey in Ekaterinburg, Russia, remarkable increase in indoor radon concentration level in energy-efficient multi-storey buildings was found in comparison with similar buildings constructed before the-energy-saving era. To investigate the problem of indoor radon in energy-efficient multi-storey buildings, the measurements of radon concentration have been performed in seven modern buildings using radon monitoring method. Values of air exchange rate and other parameters of indoor climate in energy-efficient buildings have been estimated. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Integrating advanced facades into high performance buildings

    International Nuclear Information System (INIS)

    Selkowitz, Stephen E.

    2001-01-01

    Glass is a remarkable material but its functionality is significantly enhanced when it is processed or altered to provide added intrinsic capabilities. The overall performance of glass elements in a building can be further enhanced when they are designed to be part of a complete facade system. Finally the facade system delivers the greatest performance to the building owner and occupants when it becomes an essential element of a fully integrated building design. This presentation examines the growing interest in incorporating advanced glazing elements into more comprehensive facade and building systems in a manner that increases comfort, productivity and amenity for occupants, reduces operating costs for building owners, and contributes to improving the health of the planet by reducing overall energy use and negative environmental impacts. We explore the role of glazing systems in dynamic and responsive facades that provide the following functionality: Enhanced sun protection and cooling load control while improving thermal comfort and providing most of the light needed with daylighting; Enhanced air quality and reduced cooling loads using natural ventilation schemes employing the facade as an active air control element; Reduced operating costs by minimizing lighting, cooling and heating energy use by optimizing the daylighting-thermal tradeoffs; Net positive contributions to the energy balance of the building using integrated photovoltaic systems; Improved indoor environments leading to enhanced occupant health, comfort and performance. In addressing these issues facade system solutions must, of course, respect the constraints of latitude, location, solar orientation, acoustics, earthquake and fire safety, etc. Since climate and occupant needs are dynamic variables, in a high performance building the facade solution have the capacity to respond and adapt to these variable exterior conditions and to changing occupant needs. This responsive performance capability

  3. Measurement of naturally occurring radioactive materials in commonly used building materials in Hyderabad, India

    International Nuclear Information System (INIS)

    Balbudhe, A.Y.; Vishwa Prasad, K.; Vidya Sagar, D.; Jha, S.K.; Tripathi, R.M.

    2018-01-01

    Building materials can cause significant gamma dose indoors, due to their natural radioactivity content. The knowledge of the natural radioactivity level of building materials is important for determination of population exposure, as most people spend 80-90% of their time indoors furthermore, it is useful in setting the standards and national guidelines for the use and management of these materials. The concentrations of natural radionuclides in building materials vary depending on the local geological and geographical conditions as well as geochemical characteristics of those materials. The aim of the study is to determine levels of natural radionuclide in the commonly used building materials in Hyderabad, India

  4. Assessment of building integrated energy supply and energy saving schemes on a national level in Denmark

    Energy Technology Data Exchange (ETDEWEB)

    Muenster, M.; Morthorst, P.E.; Birkl, C.

    2011-06-15

    In the future, buildings will not only act as consumers of energy but as producers as well. For these ''prosumers'', energy production by use of solar panels, photovoltaics and heat pumps etc will be essential. The objective of this project was to find the most optimal combinations of building insulation and use of renewable energy sources in existing buildings in terms of economics and climate impacts. Five houses were analyzed based on different personal load, consumption profiles, solar orientation and proposed building envelope improvements and use of combinations of renewable energy systems. The results of these analyses were integrated in five scenarios to examine the consequences at national level of implementing insulation together with solar panels, photovoltaics and heat pumps in single-family houses. The simulations focused on the building period between 1961 and 1972 characterised by high building activity and low energy performance. The five scenarios - a baseline scenario, a maximum savings scenario, a maximum production scenario, and a combination scenario - showed that regardless of scenario, a consequent use of individual heat pumps leads to the greatest energy savings and CO{sub 2} reductions. (ln)

  5. Radon measurements during the building of a low-level laboratory

    CERN Document Server

    Antanasijevic, R; Bikit, I; Banjanac, R; Dragic, A; Joksimovic, D; Krmpotic, D; Udovicic, V; Vukovic, J

    1999-01-01

    Radon measurements were provided during the different stages of building of a low-level laboratory in Belgrade. The depth of the laboratory is 12 m, equivalent to 30 m of water with an area of 45 m sup 2. The whole of the laboratory is hermetically lined with 1 mm A1 foil and is ventilated with filtered air. Radon concentrations were measured with the CR-39 detector as well as via the gamma-ray spectroscopic measurements. The radon concentrations in the air were achieved to 20 Bqm sup - sup 3 and reduction of secondary and tertiary cosmic-ray fluxes is five times when ventilation, filtering and sealing was applied.

  6. Radon measurements during the building of a low-level laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Antanasijevic, R.; Anicin, I.; Bikit, I.; Banjanac, R.; Dragic, A.; Joksimovic, D.; Krmpotic, D.; Udovicic, V.; Vukovic, J

    1999-06-01

    Radon measurements were provided during the different stages of building of a low-level laboratory in Belgrade. The depth of the laboratory is 12 m, equivalent to 30 m of water with an area of 45 m{sup 2}. The whole of the laboratory is hermetically lined with 1 mm A1 foil and is ventilated with filtered air. Radon concentrations were measured with the CR-39 detector as well as via the gamma-ray spectroscopic measurements. The radon concentrations in the air were achieved to 20 Bqm{sup -3} and reduction of secondary and tertiary cosmic-ray fluxes is five times when ventilation, filtering and sealing was applied.

  7. Radon measurements during the building of a low-level laboratory

    International Nuclear Information System (INIS)

    Antanasijevic, R.; Anicin, I.; Bikit, I.; Banjanac, R.; Dragic, A.; Joksimovic, D.; Krmpotic, D.; Udovicic, V.; Vukovic, J.

    1999-01-01

    Radon measurements were provided during the different stages of building of a low-level laboratory in Belgrade. The depth of the laboratory is 12 m, equivalent to 30 m of water with an area of 45 m 2 . The whole of the laboratory is hermetically lined with 1 mm A1 foil and is ventilated with filtered air. Radon concentrations were measured with the CR-39 detector as well as via the gamma-ray spectroscopic measurements. The radon concentrations in the air were achieved to 20 Bqm -3 and reduction of secondary and tertiary cosmic-ray fluxes is five times when ventilation, filtering and sealing was applied

  8. A questionnaire survey on sleeping thermal environment and bedroom air conditioning in high-rise residences in Hong Kong

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Z. [Institute of Heating, Ventilation, Air Conditioning and Gas Engineering, Tongji University, Shanghai (China); Deng, S. [Department of Building Services Engineering, The Hong Kong Polytechnic University, Kowloon, Hong Kong SAR (China)

    2006-07-01

    This paper reports on the results of a questionnaire survey on sleeping thermal environment and bedroom air conditioning in high-rise residential buildings in Hong Kong. The survey aimed at investigating the current situation of sleeping thermal environment and bedroom air conditioning, in order to gather relevant background information to develop strategies for bedroom air conditioning in the subtropics. It focused on the use patterns and types of bedroom air conditioning systems used, human factors such as the use of bedding and sleep wear during sleep, preference for indoor air temperature settings in bedrooms, ventilation control at nighttime with room air conditioner (RAC) turned on, etc. The results of the survey showed that most of the respondents would prefer a relatively low indoor air temperature at below 24 {sup o}C. Most of the respondents might however not be satisfied with the indoor air quality (IAQ) in bedrooms in Hong Kong. On the other hand, 68% of the respondents did not use any ventilation control intentionally during their sleep with their RACs turned on. A lack of knowledge of the ventilation control devices provided on window type room air conditioners (WRACs) indicated an urgent need for user education. (author)

  9. Responding to the deaf in disasters: establishing the need for systematic training for state-level emergency management agencies and community organizations

    Science.gov (United States)

    2013-01-01

    Background Deaf and hard-of-hearing (Deaf/HH) individuals have been underserved before and during emergencies. This paper will assess Deaf/HH related emergency preparedness training needs for state emergency management agencies and deaf-serving community-based organizations (CBOs). Methods Four approaches were used: 1) a literature review; 2) results from 50 key informant (KI) interviews from state and territorial-level emergency management and public health agencies; 3) results from 14 KI interviews with deaf-serving CBOs in the San Francisco Bay Area; and 4) a pilot program evaluation of an emergency responder training serving the Deaf/HH in one urban community. Results Results from literature review and state and territorial level KIs indicate that there is a substantive gap in emergency preparedness training on serving Deaf/HH provided by state agencies. In addition, local KI interviews with 14 deaf-serving CBOs found gaps in training within deaf-serving CBOs. These gaps have implications for preparing for and responding to all-hazards emergencies including weather-related or earthquake-related natural disasters, terrorist attacks, and nuclear-chemical disasters. Conclusion Emergency preparedness trainings specific to responding to or promoting preparedness of the Deaf/HH is rare, even for state agency personnel, and frequently lack standardization, evaluation, or institutionalization in emergency management infrastructure. This has significant policy and research implications. Similarly, CBOs are not adequately trained to serve the needs of their constituents. PMID:23497178

  10. Building when the climate gets warmer

    International Nuclear Information System (INIS)

    Brunner, C. U.; Steinemann, U.; Nipkow, J.

    2007-01-01

    This final report for the Swiss Federal Office of Energy (SFOE), takes a look at how the building process will have to take account of climate change with higher summer temperatures in Switzerland. The authors consider the situation as being in strong contrast to the past in Switzerland, when attention was devoted to energy demand in buildings during the winter. Today there is a new focus with the anticipation of increasingly frequent, extended hot spells in summer. The goal of this investigation is to analyse and present economic measures to assure a high level of summer comfort with a reduced demand for electricity under these changing conditions. Strategies with respect to construction, technology and operation are addressed. The current spread of technically questionable and inefficient room air conditioning units in residential and commercial buildings is considered as being strongly reminiscent of a dangerous, analogous case in the past, when small electric heaters became widespread. A largely untapped potential exists for increasing the efficiency of air conditioning and chiller technologies for both central systems and room units by the careful use of small temperature differences. Several new and unconventional solution paths are discussed, including high-efficiency room air conditioners, solar cooling equipment, balanced mechanical ventilation, phase-change materials, thermal storage, etc., all aimed at reducing electricity consumption. The expected additional electricity demand of around 1.9 TWh annually for ventilation and air conditioning is commented on.

  11. Building founding method

    International Nuclear Information System (INIS)

    Tateno, Seiya; Hirako, Shizuka.

    1996-01-01

    The lower portion of a reactor building is buried at a level of a base rock. In the step of building construction, the base rock around the building is dug of keeping a construction space. The base rock present between the digging line and the building is replaced with an artificial base rock comprising aggregates and cement having a building constraining force substantially equal with that of the lower supporting base rock to obtain constraining force for the side portion of the building. The building itself is made of concrete steels. As the material for replacing the base rock between the digging line and the building, non-reinforced concrete having no steels may provide sufficient function. The burying depth is determined so as to align the surface of the base rock with the level of the base floor of the building. With such procedures, since it is not necessary to increase the area of the lower portion of the building, the amount of the materials for the building can be reduced. In addition, the earthquakes stability can be ensured without changing the shape of the building. (I.N.)

  12. Summary and Conclusions by the Conference President Marta Žiaková [International Conference on Human Resource Development for Nuclear Power Programmes: Building and Sustaining Capacity, Vienna (Austria), 12-16 May 2014

    International Nuclear Information System (INIS)

    Žiaková, Marta

    2014-01-01

    • Many drivers for capacity building exist - Mature and newcomer countries, Action Plan for Nuclear Safety; • Since 2010 nuclear world has changed - Countries are very active in capacity building and IAEA responded; • e.g. new IAEA Capacity Building Self-Assessment Methodology. • Capacity building should cover full nuclear programme;• All levels important: • Individual: staff development, new curricula; • Corporate: supportive to young generation and new employees; • National: comprehensive approach needs government support; • Global: internationalization of education and careers

  13. Solar energy in buildings solved by building information modeling

    Science.gov (United States)

    Chudikova, B.; Faltejsek, M.

    2018-03-01

    Building lead us to use renewable energy sources for all types of buildings. The use of solar energy is the alternatives that can be applied in a good ratio of space, price, and resultant benefits. Building Information Modelling is a modern and effective way of dealing with buildings with regard to all aspects of the life cycle. The basis is careful planning and simulation in the pre-investment phase, where it is possible to determine the effective result and influence the lifetime of the building and the cost of its operation. By simulating, analysing and insert a building model into its future environment where climate conditions and surrounding buildings play a role, it is possible to predict the usability of the solar energy and establish an ideal model. Solar systems also very affect the internal layout of buildings. Pre-investment phase analysis, with a view to future aspects, will ensure that the resulting building will be both low-energy and environmentally friendly.

  14. Airborne asbestos fibre levels in buildings: a summary of UK measurements.

    Science.gov (United States)

    Burdett, G J; Jaffrey, S A; Rood, A P

    1989-01-01

    The UK Health and Safety Executive, in conjunction with the Department of the Environment, has carried out a number of surveys of airborne asbestos fibre concentrations in buildings. All samples have been collected on membrane filters and analysed by analytical transmission electron microscopy. Four categories of buildings under normal occupation have been investigated; non-domestic buildings containing sprayed or trowelled asbestos, domestic buildings containing sprayed asbestos or asbestos plaster, buildings with warm air heaters containing asbestos and buildings without asbestos materials. A number of buildings have also been surveyed during and after the removal of asbestos materials. The choice of measurement indices and analytical procedures is reviewed, before measurements are compared in terms of the concentration of asbestos fibres greater than 5 microns long. The decision whether to remove asbestos from occupied buildings is discussed with reference to the associated cost and risk. In the present survey, management of undamaged asbestos appeared preferable to large-scale removal.

  15. VALIDATION OF A SCALE OF LEVELS AND CONDITIONS OF ORGANIZATIONAL LEARNING

    Directory of Open Access Journals (Sweden)

    DELIO IGNACIO CASTAÑEDA

    2007-08-01

    Full Text Available Organizational learning has been studied from the perspective of levels of learning: individual, group and organizational,as well as from the needed conditions for learning in order to be produced. An instrument of six dimensions wasvalidated, three of them levels: individual, group and organizational, and three of them conditions: culture oforganizational learning, training and transmission of information. Participants were 845 workers of a public institution.From results support was found for the three levels of learning and for two conditions: culture of organizationallearning and training. Additionally a condition called strategic clarity was identified.

  16. General Managers' and building managers' different evaluation of building value and quality - as built and over time

    DEFF Research Database (Denmark)

    Jensen, Per Anker

    2007-01-01

    building. Furthermore, the respondents were asked to prioritize the quality factors. In the analysis the quality factors were grouped into cultural value and use value and into quality as built and over time. The paper presents the general results of the survey with focus on the differences between......This paper is one of the results of a research project on real estate strategies and building values based on a case study of the corporate buildings of DR (Danish Broadcasting Corporation). The paper presents some of the results from a questionnaire survey among select groups of managers in DR...... concerning their evaluation of 5 buildings. The overall purpose of the survey was to evaluate the different buildings’ values and quality, both as built and over time. A second purpose was to develop and test a methodology to describe the values and quality of buildings at a general but still differentiated...

  17. General collaboration offer of Johnson Controls regarding the performance of air conditioning automatic control systems and other buildings` automatic control systems

    Energy Technology Data Exchange (ETDEWEB)

    Gniazdowski, J.

    1995-12-31

    JOHNSON CONTROLS manufactures measuring and control equipment (800 types) and is as well a {open_quotes}turn-key{close_quotes} supplier of complete automatic controls systems for heating, air conditioning, ventilation and refrigerating engineering branches. The Company also supplies Buildings` Computer-Based Supervision and Monitoring Systems that may be applied in both small and large structures. Since 1990 the company has been performing full-range trade and contracting activities on the Polish market. We have our own well-trained technical staff and we collaborate with a series of designing and contracting enterprises that enable us to have our projects carried out all over Poland. The prices of our supplies and services correspond with the level of the Polish market.

  18. Academics respond

    DEFF Research Database (Denmark)

    Hazel, Spencer

    2015-01-01

    Contribution to the article "Academics respond: Brexit would weaken UK university research and funding", Guardian Witness, The Guardian, UK......Contribution to the article "Academics respond: Brexit would weaken UK university research and funding", Guardian Witness, The Guardian, UK...

  19. Methodology applied in Cuba for siting, designing, and building a radioactive waste repository under safety conditions

    International Nuclear Information System (INIS)

    Orbera, L.; Peralta, J.L.; Franklin, R.; Gil, R.; Chales, G.; Rodriguez, A.

    1993-01-01

    The work presents the methodology used in Cuba for siting, designing, and building a radioactive waste repository safely. This methodology covers both the technical and socio-economic factors, as well as those of design and construction so as to have a safe siting for this kind of repository under Cuba especial condition. Applying this methodology will results in a safe repository

  20. Seismic soil–structure interaction analysis of a nuclear power plant building founded on soil and in degraded concrete stiffness condition

    International Nuclear Information System (INIS)

    Farahani, Reza V.; Dessalegn, Tewodros M.; Vaidya, Nishikant R.; Bazan-Zurita, Enrique

    2016-01-01

    Highlights: • Three dimensional finite element modeling of a Nuclear Power Plant (NPP) building founded on soil is described. • A simplified technique to consider degraded stiffness of concrete members in seismic analysis of NPP buildings is presented. • The effect of subsurface profiles on the seismic response of a NPP building is investigated. - Abstract: This study describes three-dimensional (3-D) finite element (FE) modeling and seismic Soil-Structure Interaction (SSI) analysis of a Nuclear Power Plant (NPP) Diesel Generator Building (DGB) that is founded on soil in degraded concrete stiffness condition. A new technique is presented that uses two horizontal and vertical FE models to consider the concrete stiffness reduction of NPP buildings subjected to orthogonal ground motion excitations, in which appropriate stiffness reduction factors, based on the input motion orientation, are applied. Seismic SSI analysis is performed for each model separately, and dynamic responses are calculated in the three global directions. The results of the analysis for the two FE models are then combined, using the square-root-of-the-sum-of-squares (SRSS) combination rule. A sensitivity analysis is also performed to investigate the subsurface profile effect on the In-Structure (acceleration) Response Spectra (ISRS) of the building when subjected to site-specific Foundation Input Response Spectra (FIRS) that exhibit high spectral amplifications in the high-frequency range. The sensitivity analysis considers three strain-compatible subsurface profiles that represent Lower-Bound (LB), Best-Estimate (BE), and Upper-Bound (UB) conditions at the DGB site. The sensitivity analysis results indicate that the seismic response of the DGB founded on soil highly depends on the subsurface profile; i.e., each of the LB, BE, and UB subsurface profiles can maximize building seismic response when subjected to FIRS that exhibit high spectral amplifications in the high-frequency range

  1. Bellanca building, Yellowknife : building envelope retrofit project

    Energy Technology Data Exchange (ETDEWEB)

    Rajewski, G. [A.D. Williams Engineering Inc., Edmonton, AB (Canada)

    2008-07-01

    The Bellanca building is a ten-story, commercial office building, located in Yellowknife, Northwest Territories. The owner was concerned about annual fuel consumption, relative to other buildings of similar size. Tenants reported cold drafts and some ice build-up had been reported in the past, on the exterior of the cladding. In addition, some water penetration had occurred during rainfall. This presentation provided background information on the Bellanca building and discussed a building envelope retrofit project. A.D. Williams was hired in late 2006 in order to provide an opinion on the present condition of the building envelope. This presentation described the site investigation and presented an interior and exterior review of the building. It also presented a thermographic survey in order to map thermal anomalies and establish trends. Following acceptance of the report on findings, one of five options was selected for further development. This included removal of existing cladding, exterior gypsum wallboard, fiberglass insulation and application of BASF Walltite CT foam, sheathing, rigid insulation, drainage plane and new cladding. The preliminary design was then presented. This paper also described the tender and award of the contract; construction phase; and substantial completion of the project. tabs, figs.

  2. Plasma C3d levels of young farmers correlate with respirable dust exposure levels during normal work in swine confinement buildings

    DEFF Research Database (Denmark)

    Hoffmann, Hans Jürgen; Iversen, Martin; Brandslund, Ivan

    2003-01-01

    Work in swine confinement buildings leads to an inflammatory response and may be associated with increased levels of acute phase proteins. We compared the inflammatory response of a control group of young former farm workers with age-matched former farm workers who had previously developed the lo...... in response to respiratory dust, more so amongst cases than in the control group. Acute exposure, with work related levels of organic dust containing endotoxin, leads to a weak systemic inflammatory response....

  3. Physiological responding to stress in middle-aged males enriched for longevity

    DEFF Research Database (Denmark)

    Jansen, Steffy W M; van Heemst, Diana; van der Grond, Jeroen

    2016-01-01

    Individuals enriched for familial longevity display a lower prevalence of age-related diseases, such as cardiovascular- and metabolic diseases. Since these diseases are associated with stress and increased cortisol levels, one of the underlying mechanisms that may contribute to healthy longevity...... might be a more adaptive response to stress. To investigate this, male middle-aged offspring from long-lived families (n = 31) and male non-offspring (with no familial history of longevity) (n = 26) were randomly allocated to the Trier Social Stress Test or a control condition in an experimental design......-offspring and showed a trend towards lower heart rate. Offspring from long-lived families might thus be less stressed prior to potentially stressful events and consequently show overall lower levels in physiological responses. Although attenuated physiological responding cannot be ruled out, lower starting points...

  4. Reaction Norms in Natural Conditions: How Does Metabolic Performance Respond to Weather Variations in a Small Endotherm Facing Cold Environments?

    Science.gov (United States)

    Petit, Magali; Vézina, François

    2014-01-01

    Reaction norms reflect an organisms' capacity to adjust its phenotype to the environment and allows for identifying trait values associated with physiological limits. However, reaction norms of physiological parameters are mostly unknown for endotherms living in natural conditions. Black-capped chickadees (Poecile atricapillus) increase their metabolic performance during winter acclimatization and are thus good model to measure reaction norms in the wild. We repeatedly measured basal (BMR) and summit (Msum) metabolism in chickadees to characterize, for the first time in a free-living endotherm, reaction norms of these parameters across the natural range of weather variation. BMR varied between individuals and was weakly and negatively related to minimal temperature. Msum varied with minimal temperature following a Z-shape curve, increasing linearly between 24°C and −10°C, and changed with absolute humidity following a U-shape relationship. These results suggest that thermal exchanges with the environment have minimal effects on maintenance costs, which may be individual-dependent, while thermogenic capacity is responding to body heat loss. Our results suggest also that BMR and Msum respond to different and likely independent constraints. PMID:25426860

  5. Responding To Changes in the Decommissioning Plans for Demolition of a Former Active Handling Building at The United Kingdom Atomic Energy Establishment Winfrith

    International Nuclear Information System (INIS)

    Brown, N.; Parkinson, S.J.; Cornell, R.M.; Staples, A.T.

    2006-01-01

    The full decommissioning of the former Active Handling Building A59 at Winfrith in Dorset is being carried out by RWE NUKEM Limited under contract from the site owners and nuclear site licence holder, United Kingdom Atomic Energy Authority (UKAEA). Following recent government changes, the United Kingdom's Nuclear Decommissioning Authority (NDA) has now set up contracts with UKAEA for delivery of the site clean-up programme. The building contains two heavily shielded suites of caves originally used to carry out remote examination of irradiated nuclear fuel elements together with other supporting facilities. The original intention was to demolish the caves ahead of the building but after detailed consideration it was concluded that demolition of the building in advance of the caves was more operationally effective. As a result, the original decommissioning plan had to be reworked to reflect these changes. The paper briefly explains how this situation arose and the means by which the problems experienced were overcome by a complete revision to the decommissioning programme. The updated plan has been adopted by UKAEA and work is now proceeding apace to clear the building of redundant items, to complete decontamination of all remaining areas and facilities and to carry out detailed radiological surveys to confirm that the building structure is clean and ready for demolition. Both cave lines have been completely decontaminated to low residual levels of activity and are essentially ready for controlled demolition. This paper describes some of the significant tasks undertaken during the past year with particular reference to the decommissioning techniques that gave the greatest success and the limitations of others originally considered. Some of these processes were aimed at minimising the volume of low level waste (LLW) generated by using standard off-the-shelf equipment to remove contamination from ∼5 Ton concrete blocks recovered from both cave line structures. A

  6. Influence of the conditional release of the materials with very low level of radioactivity on the environment - 59132

    International Nuclear Information System (INIS)

    Prvakova, Slavka; Mrskova, Adela; Pritrsky, Jozef

    2012-01-01

    Significant amount of solid materials (metals, non-metals, building structures) that could be contaminated or activated is produced during operation and especially decommissioning of nuclear power plants. Considerable fraction of these materials has level of radioactivity close to the radiological limits allowing its safe release into the environment thereby could be potentially recycled within the special constructions, as for example tunnels, roads or bridges. If the requirements of legislation on the radiological limits for handling such material and long-term safety of the constructions are met, contaminated material can be incorporated in the form of recycled concrete, remelted steel, etc. The paper presents implementation of the IAEA and EC recommendations into the form of detailed analytical approaches with the aim to develop integrated scenarios and to analyse long-term influence of the conditional release of the material with very low level of radioactivity on the environment. Further, an estimation of the key input parameters characteristic for the specific conditions of Slovak case in order to fulfil the radiological limits according to the Slovak legislation is included. Analysed integrated scenarios represent surface or underground civil construction with radionuclides released directly into the geosphere and transported by a groundwater flow to the biosphere. The migration of radionuclides is modelled in the near-surface conditions with the advection as a dominant transport mechanism. Computer code GoldSim is used to evaluate the long-term safety assessment of the conditionally released material on the environment. (authors)

  7. Building Maintenance in Old Buildings Conservation Approach: An Overview of Related Problems

    Directory of Open Access Journals (Sweden)

    Brit Kayan

    2006-12-01

    Full Text Available Building maintenance in conservation of old buildings is one of the approaches applied within the built environment of Malaysia. For instance, it is realised that these old buildings contribute an important significance to our nation's priceless heritage and unique historical development. However, most of these buildings' maintenance is influenced by related problems that affect the overall building conservation approach. Therefore, these old buildings face problems which greatly affect their overall condition and performance: building structure; building appearance and aesthetic; building materials and building character. In most critical situations, there is a greater possibility that we could lose the cultural significance and heritage values of these old buildings through ignoring the related problems. This paper tries to identify the related problems, reveal the findings and discuss suitable approaches to conserving these old buildings.

  8. Housing conditions affecting interior moisture levels: links to mould growth and children's respiratory health

    Energy Technology Data Exchange (ETDEWEB)

    Wells, John A. [Crosier Kilgour and Partners Ltd. (Canada)], email: john.w@ckpeng.com; Polyzois, Dimos [Department of Civil Engineering, University of Manitoba (Canada)], email: polyzoi@cc.umanitoba.ca; Polyzoi, Eleoussa [Faculty of Education, University of Winnipeg (Canada)], email: l.polyzoi@uwinnipeg.ca

    2011-07-01

    Previous research has demonstrated that a person's respiratory health is affected by high indoor moisture content in their house. The aim of this paper is to provide a better understanding of the link between housing conditions and respiratory health, so that strategies can be implemented to improve the quality of life of children. This study was carried out through the completion of a survey by 3,423 parents in Winnipeg, Canada, the collection of 715 air samples from the residences of 715 parents, and an engineering audit of their homes. This study showed that a strong relationship exists between building moisture content and common home maintenance and that routine maintenance is efficient in significantly reducing the growth of mould which impacts children's respiratory health. This paper provided useful information on the relation between housing conditions and respiratory health problems and the rest of the study will aim at determining which building conditions impact mould growth most.

  9. Dependence of indoor 222Rn level on building materials

    International Nuclear Information System (INIS)

    Tso, M.W.; Ng, C.; Leung, J.K.C.

    1993-01-01

    The radionuclide contents of typical building materials used in Hong Kong were studied by γ spectroscopic analysis. The physical properties of these building materials affecting the production and transportation of 222 Rn to the surrounding air were examined; these include the emanation coefficient of 2 '2 2 Rn of the material, the diffusion coefficient of 222 Rn in the material and the effect of surface coating and temperature on the rate of 222 Rn exhalation. Results obtained in this study explain the indoor 222 Rn concentration observed in our previous surveys and also suggest that the main source of indoor 222 Rn in Hong Kong is building material. (3 figs., 4 tabs.)

  10. Evaluation of conditioned high-level waste forms

    International Nuclear Information System (INIS)

    Mendel, J.E.; Turcotte, R.P.; Chikalla, T.D.; Hench, L.L.

    1983-01-01

    The evaluation of conditioned high-level waste forms requires an understanding of radiation and thermal effects, mechanical properties, volatility, and chemical durability. As a result of nuclear waste research and development programs in many countries, a good understanding of these factors is available for borosilicate glass containing high-level waste. The IAEA through its coordinated research program has contributed to this understanding. Methods used in the evaluation of conditioned high-level waste forms are reviewed. In the US, this evaluation has been facilitated by the definition of standard test methods by the Materials Characterization Center (MCC), which was established by the Department of Energy (DOE) in 1979. The DOE has also established a 20-member Materials Review Board to peer-review the activities of the MCC. In addition to comparing waste forms, testing must be done to evaluate the behavior of waste forms in geologic repositories. Such testing is complex; accelerated tests are required to predict expected behavior for thousands of years. The tests must be multicomponent tests to ensure that all potential interactions between waste form, canister/overpack and corrosion products, backfill, intruding ground water and the repository rock, are accounted for. An overview of the status of such multicomponent testing is presented

  11. Natural ventilation systems to enhance sustainability in buildings: a review towards zero energy buildings in schools

    Science.gov (United States)

    Gil-Baez, Maite; Barrios-Padura, Ángela; Molina-Huelva, Marta; Chacartegui, Ricardo

    2017-11-01

    European regulations set the condition of Zero Energy Buildings for new buildings since 2020, with an intermediate milestone in 2018 for public buildings, in order to control greenhouse gases emissions control and climate change mitigation. Given that main fraction of energy consumption in buildings operation is due to HVAC systems, advances in its design and operation conditions are required. One key element for energy demand control is passive design of buildings. On this purpose, different recent studies and publications analyse natural ventilation systems potential to provide indoor air quality and comfort conditions minimizing electric power consumption. In these passive systems are of special relevance their capacities as passive cooling systems as well as air renovation systems, especially in high-density occupied spaces. With adequate designs, in warm/mild climates natural ventilation systems can be used along the whole year, maintaining indoor air quality and comfort conditions with small support of other heating/cooling systems. In this paper is analysed the state of the art of natural ventilation systems applied to high density occupied spaces with special focus on school buildings. The paper shows the potential and applicability of these systems for energy savings and discusses main criteria for their adequate integration in school building designs.

  12. Exploring community resilience in workforce communities of first responders serving Katrina survivors.

    Science.gov (United States)

    Wyche, Karen Fraser; Pfefferbaum, Rose L; Pfefferbaum, Betty; Norris, Fran H; Wisnieski, Deborah; Younger, Hayden

    2011-01-01

    Community resilience activities were assessed in workplace teams that became first responders for Hurricane Katrina survivors. Community resilience was assessed by a survey, focus groups, and key informant interviews. On the survey, 90 first responders ranked their team's disaster response performance as high on community resilience activities. The same participants, interviewed in 11 focus groups and 3 key informant interviews, discussed how their teams engaged in community resilience activities to strengthen their ability to deliver services. Specifically, their resilient behaviors were characterized by: shared organizational identity, purpose, and values; mutual support and trust; role flexibility; active problem solving; self-reflection; shared leadership; and skill building. The implications for research, policy, practice, and education of professionals are discussed. © 2011 American Orthopsychiatric Association.

  13. Multi-Scenario Use Case based Demonstration of Buildings Cybersecurity Framework Webtool

    Energy Technology Data Exchange (ETDEWEB)

    Gourisetti, Sri Nikhil G.; Mylrea, Michael E.; Gervais, Easton L.; Bhadra, Sraddhanjoli

    2017-11-27

    The purpose of this paper is to demonstrate the cybersecurity and software capabilities of Buildings Cybersecurity Framework (BCF) webtool. The webtool is designed based on BCF document and existing NIST standards. It’s capabilities and features are depicted through a building usecase with four different investment scenarios geared towards improving the cybersecurity posture of the building. BCF webtool also facilitates implementation of the goals outlined in Presidential Executive Order (EO) on Strengthening the Cybersecurity of Federal Networks and Critical Infrastructure (May 2017. In realization of the EO goals, BCF includes five core elements: Identify, Protect, Detect, Respond, and Recover, to help determine various policy and process level vulnerabilities and provide mitigation strategies. With the BCF webtool, an organization can perform a cybersecurity self-assessment; determine the current cybersecurity posture; define investment based goals to achieve a target state; connect the cybersecurity posture with business processes, functions, and continuity; and finally, develop plans to answer critical organizational cybersecurity questions. In this paper, the webtool and its core capabilities are depicted by performing an extensive comparative assessment over four different scenarios.

  14. Effect of reactor conditions on MSIV-ATWS power level

    International Nuclear Information System (INIS)

    Diamond, D.J.

    1987-01-01

    In a boiling water reactor (BWR) when there is closure of the main steam isolation valves (MSIVs), the energy generated in the core will be transferred to the pressure suppression pool (PSP) via steam that flows out of the relief valves. The pool has limited capacity as a heat sink and hence, if there is no reactor trip [an anticipated transient without scram (ATWS) event], there is the possibility that the pool temperature may rise beyond acceptable limits. The present study was undertaken to determine how the initial reactor conditions affect the power level during an MSIV-ATWS event. The time of interest is the 20- to 30-min period when it is assumed that the reactor is in a quasi equilibrium condition with the water level and pressure fixed, natural circulation conditions and no control rod movement or significant boron in the core. The initial conditions of interest are the time of the cycle and the operating state

  15. Culture conditions affect photoreactivating enzyme levels in human fibroblasts

    International Nuclear Information System (INIS)

    Sutherland, B.M.; Oliver, R.

    1976-01-01

    Photoreactivation of pyrimidine dimers occured under the experimental conditions given in this study, but has not been observed under conditions used by others. Three possible differences were tested in experimental procedures including dimer separation and analysis methods, illumination conditions and cell culture techniques. The methods in this study of dimer separation and analysis indeed measure cis-syn pyrimidine dimers and give results in quantitative agreement with the methods of others. It was found that white light pre-illumination of fibroblasts from the xeroderma pigmentosum line XP12BE or of normal cells does not affect the cellular capacity for dimer photoreactivation. However, the cell culture conditions can affect photoreactivating enzyme levels, and thus cellular dimer photoreactivation capacity. Cells grown in Eagle's minimal essential medium (supplemented with 15% fetal bovine serum) contain very low levels of photoreactivating enzyme and cannot photoreactivate dimers in their DNA; but companion cultures maintained in Dulbecco's modified Eagle's minimal medium do contain photoreactivating enzyme and can reactivate photoreactive cellular dimers

  16. Design of a distributed simulation environment for building control applications based on systems engineering methodology

    NARCIS (Netherlands)

    Yahiaoui, Azzedine

    2018-01-01

    The analysis of innovative designs that distributes control to buildings over a network is currently a challenging task as exciting building performance simulation tools do not offer sufficient capabilities and the flexibility to fully respond to the full complexity of Automated Buildings (ABs). For

  17. Lux level enhancement and reduction in electricity cost in commercial buildings by retrofitting with PMR luminaries

    International Nuclear Information System (INIS)

    Mariun, N.; Mohibullah; Jasni, J.; Lam, S.Y.

    2006-01-01

    Most of the existing commercial buildings are illuminated by luminaries systems during broad daylight and night which is provided by the renowned lighting industry. However, back in 1980s, the installed luminaries within the office compound were limited in choice of luminaire selection and cost factor impact. Some of the old commercial building are still using prismatic acrylic lens diffuser luminaries in order to brighten up the building for their business activities and a large number of luminaries are needed to illuminate equivalent illumination level as per requirement of the building bye-laws code. With the advancement in luminaries technology, the lighting industries have offered better solution to reduce energy costs by 50% or more, also able to improve the quality of light and reducing the quantity of luminaries requirement by introducing the parabolic mirror reflector (PMR) luminaries system. The selected commercial building as a case study to support this luminaries retrofitting program by comparing the existing luminaries with the retrofit luminaries in terms of the lux measurement and energy cost saving calculation is presented in this paper. Nevertheless, some general lighting design principle rules are also discussed

  18. Radon in buildings

    International Nuclear Information System (INIS)

    Ryan, N.M.; Finn, M.

    1995-01-01

    This guide is intended to inform designers, contractors, householders and other building owners about radon in buildings and to provide guidance where it has been decided to take action to reduce radon levels. It gives some pointers to good practice insofar as it relates to non complex buildings of normal design and construction. Reference is made to the usual ways of reducing l;levels of radon and guidance is given on sources of further information. I

  19. Using pharmacokinetic-pharmacodynamic modelling as a tool for prediction of therapeutic effective plasma levels of antipsychotics

    DEFF Research Database (Denmark)

    Olsen, Christina Kurre; Brennum, Lise Tøttrup; Kreilgaard, Mads

    2008-01-01

    response behaviour correlates well with the relationship between human dopamine D2 receptor occupancy and clinical effect. The aim of the present study was to evaluate how pharmacokinetic/pharmacodynamic (PK/PD) predictions of therapeutic effective steady-state plasma levels by means of conditioned...... the rat dopamine D2 receptor occupancy levels providing 50% response in the conditioned avoidance response test and the dopamine D2 receptor occupancy levels reported from responding schizophrenic patients treated with antipsychotics. Predictions of therapeutically effective steady-state levels...... for sertindole (+dehydrosertindole) and olanzapine were 3-4-fold too high whereas for haloperidol, clozapine and risperidone the predicted steady-state EC50 in conditioned avoidance responding rats correlated well with the therapeutically effective plasma levels observed in patients. Accordingly, the proposed PK...

  20. Management Model for efficient quality control in new buildings

    Directory of Open Access Journals (Sweden)

    C. E. Rodríguez-Jiménez

    2017-09-01

    Full Text Available The management of the quality control of each building process is usually set up in Spain from different levels of demand. This work tries to obtain a model of reference, to compare the quality control of the building process of a specific product (building, and to be able to evaluate its warranty level. In the quest of this purpose, we take credit of specialized sources and 153 real cases of Quality Control were carefully revised using a multi-judgment method. Applying different techniques to get a specific valuation (impartial of the input parameters through Delphi’s method (17 experts query, whose matrix treatment with the Fuzzy-QFD tool condenses numerical references through a weighted distribution of the selected functions and their corresponding conditioning factors. The model thus obtained (M153 is useful in order to have a quality control reference to meet the expectations of the quality.

  1. Derived concentration guideline levels for Argonne National Laboratory's building 310 area.

    Energy Technology Data Exchange (ETDEWEB)

    Kamboj, S., Dr.; Yu, C ., Dr. (Environmental Science Division)

    2011-08-12

    The derived concentration guideline level (DCGL) is the allowable residual radionuclide concentration that can remain in soil after remediation of the site without radiological restrictions on the use of the site. It is sometimes called the single radionuclide soil guideline or the soil cleanup criteria. This report documents the methodology, scenarios, and parameters used in the analysis to support establishing radionuclide DCGLs for Argonne National Laboratory's Building 310 area.

  2. The North Cascadia Adaptation Partnership: a science-management collaboration for responding to climate change

    Science.gov (United States)

    Crystal L. Raymond; David L. Peterson; Regina M. Rochefort

    2013-01-01

    The U.S. Forest Service (USFS) and National Park Service (NPS) have highlighted climate change as an agency priority and issued direction to administrative units for responding to climate change. In response, the USFS and NPS initiated the North Cascadia Adaptation Partnership (NCAP) in 2010. The goals of the NCAP were to build an inclusive partnership, increase...

  3. Energy managemant through PCM based thermal storage system for building air-conditioning: Tidel Park, Chennai

    International Nuclear Information System (INIS)

    Nallusamy, N.; Sampath, S.; Velraj, R.

    2006-01-01

    Many modern building are designed for air-conditioning and the amount of electrical energy required for providing air-conditioning can be very significant especially in the tropics. Conservation of energy is major concern to improve the overall efficiency of the system. Integration is energy storage with the conventional system gives a lot of potential for energy saving and long-term economics. Thermal energy storage systems can improve energy management and help in matching supply and demand patterns. In the present work, a detailed study has been done on the existing thermal energy storage system used in the air-conditioning system in Tidel Park, Chennai. The present study focuses on the cool energy storage system. The modes of operation and advantages of such a system for energy management are highlighted. The reason for the adoption of combined storage system and the size of the storage medium in the air-conditioning plant are analyzed. The possibility of using this concept in other cooling and heating applications, such as storage type solar water heating system, has been explored

  4. Mycobacterium tuberculosis Transcription Machinery: Ready To Respond to Host Attacks

    Science.gov (United States)

    Flentie, Kelly; Garner, Ashley L.

    2016-01-01

    Regulating responses to stress is critical for all bacteria, whether they are environmental, commensal, or pathogenic species. For pathogenic bacteria, successful colonization and survival in the host are dependent on adaptation to diverse conditions imposed by the host tissue architecture and the immune response. Once the bacterium senses a hostile environment, it must enact a change in physiology that contributes to the organism's survival strategy. Inappropriate responses have consequences; hence, the execution of the appropriate response is essential for survival of the bacterium in its niche. Stress responses are most often regulated at the level of gene expression and, more specifically, transcription. This minireview focuses on mechanisms of regulating transcription initiation that are required by Mycobacterium tuberculosis to respond to the arsenal of defenses imposed by the host during infection. In particular, we highlight how certain features of M. tuberculosis physiology allow this pathogen to respond swiftly and effectively to host defenses. By enacting highly integrated and coordinated gene expression changes in response to stress, M. tuberculosis is prepared for battle against the host defense and able to persist within the human population. PMID:26883824

  5. Radon in buildings

    International Nuclear Information System (INIS)

    Connell, J.J.

    1991-01-01

    This guide is intended to inform designers, householders and other building owners about the radon problem and to help in deciding if there is need to take any action to reduce radon levels in their homes or other buildings.It explains what radon is, how it enters buildings and what effect it may have on health. Reference is made to some of the usual ways of reducing the level of radon and guidance is given on some sources of assistance

  6. Simulation of temperature in office with building integrated heating and cooling system

    DEFF Research Database (Denmark)

    Weitzmann, Peter

    2002-01-01

    In this paper a numerical investigation of the thermal indoor environment has been performed for an office with building integrated hydronic heating and cooling system. Today office buildings are designed in such a way, and have such high internal heat loads and solar gains, that some kind...... of cooling is normally necessary for most of the year. Even in as cool climates as in the Nordic countries. The way the cooling is often achieved is through air conditioning. This can in many cases lead to sick building syndrome (SBS) symptoms, and furthermore it results in high energy consumption periods...... the temperature of the concrete to a level slightly below the desired room temperature, the concrete will work as an absorber for the excess heat in the office. This can significantly reduce the need for air conditioning, which will give both improved indoor climate and lower energy costs in the building...

  7. Building customer relationships as retention strategy in the South African domestic passenger airline industry

    Directory of Open Access Journals (Sweden)

    Pierre Mostert

    2010-12-01

    Full Text Available Organisations are increasingly focusing on building long-term relationships with customers, thereby increasing their probability for success by offering customers higher levels of satisfaction, increasing customer loyalty, and ultimately retaining customers. Airlines in particular can benefit from retaining customers as the airline industry is characterised by fierce competition and many airlines are finding it difficult to survive against the backdrop of enormous challenges in the past decade, including the significant decline in demand for air travel together with rising costs and the worldwide economic downturn. This study investigates the effect which a strategy by airlines of building relationships with customers has on customer satisfaction, loyalty, and ultimately customer retention. The effect of service failures on customers' relationships with airlines are also considered as a negative experience could results in customers defecting to competitors. A questionnaire, comprising six sections, was specifically compiled to determine customer retention in the South African domestic passenger airline industry. Data were collected by trained fieldworkers from OR Tambo International Airport by means of a non-probability convenience sampling method from 324 passengers flying with the various domestic airlines. Findings indicate that most respondents were satisfied with the airlines' overall service; respondents who formed relationships with domestic airlines were more loyal toward the airlines; and the relationships of respondents who were satisfied with airlines' service recovery efforts were either strengthened or unchanged. The findings from this study support findings from international studies by providing a unique South African perspective on the effect of a strategy of building relationships with customers on their satisfaction, loyalty and ultimately retention. It can therefore be recommended that the organisations competing in the South

  8. A Study to Compare the Cost of Operation and Maintenance in Green Building Index (GBI and Non-Green Building Index (Non-GBI Rated Building in Malaysia

    Directory of Open Access Journals (Sweden)

    Ping Lee Zheng

    2016-01-01

    Full Text Available Urges for sustainable development had pushed the government and professional bodies to respond and react by implementing regulations where possible to direct development in that manner. However, the outcome in most financial conferences and dialogues on sustainable buildings flagged on high construction and maintenance cost. Thus, this study is conducted to collect and analyze actual building operation and maintenance cost between GBI and Non-GBI rated buildings in Malaysia which are more than 2 years fully operated buildings. There are two categories of selected buildings which are residential and non-residential type of building. Each category of the building consists of similar building’s characteristic such as geographic location, mode of operation, building heights, total numbers of floors and units. The scope of building’s maintenance for this study is mainly on wear and tear of the wall painting, electrical light fittings, ceiling panels, roofing system and mechanical services like water pump system are recorded for their replacement frequency of service and the cost involved within a consistent period of 12 months operation at cost percentage saving of 78.9% and 40.4% for residential and non-residential buildings respectively compare against Non-GBI rated buildings. Electricity consumption for GBI rated buildings are lower than Non-GBI rated buildings which recorded at the cost variance of 23.8% and 6.3% and water consumption at 35.9% and 44.0% for the above mentioned two main categories of selected case study buildings. Results from this study conclude major savings on residential buildings category in term of maintenance cost and electricity consumption for GBI rated buildings. Whereby, non-residential category of buildings, GBI rated building had been proven to obtain significant savings in terms of maintenance cost and water consumption.

  9. A comparison of physical and psychological features of responders and non-responders to cervical facet blocks in chronic whiplash

    Science.gov (United States)

    2013-01-01

    Background Cervical facet block (FB) procedures are often used as a diagnostic precursor to radiofrequency neurotomies (RFN) in the management of chronic whiplash associated disorders (WAD). Some individuals will respond to the FB procedures and others will not respond. Such responders and non-responders provided a sample of convenience to question whether there were differences in their physical and psychological features. This information may inform future predictive studies and ultimately the clinical selection of patients for FB procedures. Methods This cross-sectional study involved 58 individuals with chronic WAD who responded to cervical FB procedures (WAD_R); 32 who did not respond (WAD_NR) and 30 Healthy Controls (HC)s. Measures included: quantitative sensory tests (pressure; thermal pain thresholds; brachial plexus provocation test); nociceptive flexion reflex (NFR); motor function (cervical range of movement (ROM); activity of the superficial neck flexors during the cranio-cervical flexion test (CCFT). Self-reported measures were gained from the following questionnaires: neuropathic pain (s-LANSS); psychological distress (General Health Questionnaire-28), post-traumatic stress (PDS) and pain catastrophization (PCS). Individuals with chronic whiplash attended the laboratory once the effects of the blocks had abated and symptoms had returned. Results Following FB procedures, both WAD groups demonstrated generalized hypersensitivity to all sensory tests, decreased neck ROM and increased superficial muscle activity with the CCFT compared to controls (p 0.05). Both WAD groups demonstrated psychological distress (GHQ-28; p < 0.05), moderate post-traumatic stress symptoms and pain catastrophization. The WAD_NR group also demonstrated increased medication intake and elevated PCS scores compared to the WAD_R group (p < 0.05). Conclusions Chronic WAD responders and non-responders to FB procedures demonstrate a similar presentation of sensory disturbance, motor

  10. Why building capacity is a necessary but insufficient condition for improved waste management in South Africa: The knowledge–behaviour relationship

    CSIR Research Space (South Africa)

    Godfrey, Linda K

    2010-10-01

    Full Text Available beliefs form behavioural intentions which result in behaviour. Findings show that building capacity, which support control beliefs, while certainly a necessary condition, is insufficient to change waste behaviour. Consideration needs to be given...

  11. Increasing energy efficiency level of building production based on applying modern mechanization facilities

    Science.gov (United States)

    Prokhorov, Sergey

    2017-10-01

    Building industry in a present day going through the hard times. Machine and mechanism exploitation cost, on a field of construction and installation works, takes a substantial part in total building construction expenses. There is a necessity to elaborate high efficient method, which allows not only to increase production, but also to reduce direct costs during machine fleet exploitation, and to increase its energy efficiency. In order to achieve the goal we plan to use modern methods of work production, hi-tech and energy saving machine tools and technologies, and use of optimal mechanization sets. As the optimization criteria there are exploitation prime cost and set efficiency. During actual task-solving process we made a conclusion, which shows that mechanization works, energy audit with production juxtaposition, prime prices and costs for energy resources allow to make complex machine fleet supply, improve ecological level and increase construction and installation work quality.

  12. Structural, geographic, and social factors in urban building energy use: Analysis of aggregated account-level consumption data in a megacity

    International Nuclear Information System (INIS)

    Porse, Erik; Derenski, Joshua; Gustafson, Hannah; Elizabeth, Zoe; Pincetl, Stephanie

    2016-01-01

    Residential and commercial buildings comprise approximately forty percent of total energy consumption and carbon dioxide emissions in the U.S. Yet, while California spends $1.5 billion annually on energy efficiency programs, limited research has explored how building energy consumption varies within cities, including the social and structural factors that influence electricity and natural gas use. We present results from an analysis of aggregated account-level utility billing data for energy consumption across the over two million properties in Los Angeles County. Results show that consumption in L.A. County varies widely with geography, income, building characteristics, and climate. Several higher-income areas have greater total energy use per building even in cooler climates, while many lower-income regions rank higher for energy use per square-foot. Energy consumption also correlates with building age, which varies widely throughout the region. Our results demonstrate the many complex and interrelated factors that influence urban energy use. While billing data is critical for devising energy efficiency programs that actually realize estimated savings and promote more sustainable cities, opening access to such data presents significant challenges for protecting personal privacy. The presented approach is adaptable and scalable to cities seeking to develop data-driven policies to reduce building energy use. - Highlights: •Building energy use varies widely across metropolitan Los Angeles. •Building age, household income, home ownership rates, and land use are all correlated with energy consumption. •High-income areas use more energy per building, while lower-income areas use more energy per square-foot. •Account-level energy use data can help local governments devise conservation strategies. •Energy efficiency programs need evaluated using energy consumption data.

  13. Dynamic window daylighting systems: electropolymeric technology for solar responsive building envelopes

    Science.gov (United States)

    Krietemeyer, Elizabeth A.; Smith, Shane I.; Dyson, Anna H.

    2011-04-01

    Human health and energy problems associated with the lack of control of sunlight in contemporary buildings have necessitated research into dynamic windows for energy efficient buildings. Existing window technologies have made moderate progress towards greater energy performance for facades but remain limited in their response to dynamic solar conditions, building energy requirements, and variable user preferences for visual comfort. Recent developments in electropolymeric display technology provide opportunities to transfer electroactive polymers to windows that can achieve high levels of geometric and spectral selectivity through the building envelope in order to meet the lighting, thermal and user requirements of occupied spaces. Experimental simulations that investigate daylight quality, energy performance, and architectural effects of electropolymeric glazing technology are presented.

  14. Experimental performance evaluation of solid concrete and dry insulation materials for passive buildings in hot and humid climatic conditions

    International Nuclear Information System (INIS)

    Rehman, Hassam Ur

    2017-01-01

    Highlights: • Experimental investigation of building insulation materials in UAE from 2012–2014. • Four same calorimeters with different south walls were built in open air laboratory. • Heat flux was reduced by 22–75% in steady state analysis during summer by insulation. • Hence, energy consumption for cooling was reduced by an average 7.6–25.3%. • Heat flow was steady in free floating analysis in winter through insulated walls. - Abstract: It is known that enhancement of building energy efficiency can help in reducing energy consumption. The use of the solar insulating materials are the most efficient and cost effective passive methods for reducing the cooling requirements of the buildings. Apart from theoretical studies, no detailed experimental studies were performed in the UAE on energy savings by using solar insulation materials on buildings. Four (3 m × 3 m × 3 m) solar calorimeters were built in RAK, UAE in order to perform an open air outdoor test for energy savings obtained with solar insulating materials. The design is aimed to determine the heat flux reduction and the energy savings achieved with and without different solar insulating materials, mounted at the south wall of solar calorimeters with similar indoor and ambient conditions. Experimental results are discussed to evaluate the thermal performance during high temperature conditions in summer’s period when cooling demand of the building is at its peak and also in winters when there is no cooling demand. The test is from 2012 to 2014. The controlled-temperature experimental study at a set point of 24 °C showed that if the standard building material, i.e. solid concrete, is retrofitted with polyisocyanurate (PIR) and reflective coatings or completely replaced with energy-efficient dry insulation material walls such as exterior insulation finishing system (EIFS), energy savings up to an average of 7.6–25.3% can be achieved. This is due to the reduction of heat flux by an

  15. Sick building syndrome

    Directory of Open Access Journals (Sweden)

    Tjandra Y. Aditama

    2002-06-01

    Full Text Available Sick building syndrome describes a number of mostly unspesific complaints of some occupants of the building. The exact pathophysiological mechanism remains elusive. It is a multi factorial event which may include physical, chemical, biological as well as psycological factors. In many cases it is due to insufficient maintenance of the HVAC (heating, ventilation, air conditioning system in the building. Sign and symptoms can be uncomfortable and even disabling, which may include mucus membrane irritation, neurotoxic symptoms, asthma like symptoms, skin complaints, gastrointestinal symptoms and other related symptoms. There are various investigation methods to diagnose sick building syndrome, and on site assessment of the building is extremely useful. Prevention through a proactive air quality monitoring program is far more desirable than dealing with an actual sick building. Indoor air and the sick building symdrome serves as a paradigm of modern occupational and environmental medicine. (Med J Indones 2002; 11:124-31Keywords: indoor air pollution, sick building syndrome, building related illness

  16. Relationship between Quality of Building Maintenance Management Services for Indoor Environmental Quality and Occupant Satisfaction: Case Study of Bus Terminal Buildings in Penang

    Directory of Open Access Journals (Sweden)

    Full Chong Choon

    2014-01-01

    Full Text Available Maintenance is often defined as the series of activities undertaken to take care of the building structure and services to ensure the intended functions and optimal performance of a building life cycle. The management department of a building is usually responsible for the enhancement of the indoor environment quality by service delivery and for boosting occupant productivity and satisfaction. Thus, a salient point of this study is to determine the current level of the building’s maintenance management service for indoor environmental quality in Penang bus terminals, along with its occupant satisfaction with regards to the services provided in the building. The assessment of the indoor environmental quality includes the evaluation of thermal comfort, lighting condition, air quality and cleanliness. Apart from that, qualitative and quantitative methodologies were applied during the process of data collection and analysis. A questionnaire survey was distributed to 500 of the targeted population for each bus terminal, including passengers and the staff. In this study, the conclusion was drawn in which the maintenance management service level of the bus terminal was directly proportional to occupant satisfaction. However, the current quality of maintenance management services in the bus terminals are still not up to the level of the occupants’ satisfaction.

  17. A low-energy building under arctic conditions – a case study

    DEFF Research Database (Denmark)

    Norling, Casper Roland; Rode, Carsten; Svendsen, Svend

    2006-01-01

    Greenland is a relatively small community with limited natural resources, which results in the necessity to import all supplies, including a big share of the energy. Because of this, it is important to decrease the energy consumption. This can be done by developing new construction technology wit...... in the new Greenlandic building regulations....... with larger focus on energy efficiency. Therefore a low-energy house, located in Sisimiut, has been constructed. The low-energy house will be a forerunner for the development of new building element designs and technologies in Greenland. In the forthcoming years, the house will also be a base for scientific...... projects which will evaluate the design of the low-energy house including an assessment of the effect of the highly insulated building envelope, advanced windows and a ventilation system with heat recovery, all of which cuts the energy consumption of the building to half of what will be the requirement...

  18. Building a culture of innovation a practical framework for placing innovation at the core of your business

    CERN Document Server

    Beswick, Cris; Geraghty, Jo

    2015-01-01

    Being a truly innovative company is more than the dreaming up of new products and services by external consultants and internal taskforces. Staying one step ahead of the competition requires you to embed innovation into your organizational culture. Innovation needs to be embodied in everything that gets done by everyone who works there. By changing your organizational culture to one that supports innovation, you will remove the barriers that stop you responding quickly and agilely to changing market conditions and opportunities for growth. Building a Culture of Innovation presents a practical framework that you can follow to design and embed a culture of innovation in your business.The six-step Innovation Culture Change Framework offers a structured process to make change stick, from assessing your organization's innovation-readiness to leading a managed change process that will foster innovation at each level. It includes case studies from international organizations which have shifted their focus to an inno...

  19. Retrofitting solutions for two different occupancy levels of educational buildings in tropics

    Science.gov (United States)

    Yang, Junjing; Pantazaras, Alexandros; Lee, Siew Eang; Santamouris, Mattheos

    2018-01-01

    Within the multi-functionality of educational buildings, the energy conservation potential can be very different. In addition, among different retrofitting solutions investigated involving interventions on the building envelope, ventilation strategies, artificial lighting systems as well as equipment upgrading, different saving potential would come from different aspects. The opportunities for energy saving potential from the overall point of view and from the detailed aspect view of different retrofitting solutions would be very useful and important for building renovation decision making. This study presents a detailed retrofitting study of two different educational buildings. One represents a building with average occupancy variation and containing mainly offices and labs. The other one represents a building with high occupancy variation and containing mainly lecture rooms and studios. This comparison of the results gives an idea of the different energy saving potential for different types of educational buildings. Principal component analysis is also adopted to investigate the detailed performance of one of the buildings which is influenced stronger by these retrofitting solutions.

  20. A New Building-Integrated Wind Turbine System Utilizing the Building

    Directory of Open Access Journals (Sweden)

    Jeongsu Park

    2015-10-01

    Full Text Available This paper proposes an innovative building-integrated wind turbine (BIWT system by directly utilizing the building skin, which is an unused and unavailable area in all conventional BIWT systems. The proposed system has been developed by combining a guide vane that is able to effectively collect the incoming wind and increase its speed and a rotor with an appropriate shape for specific conditions. To this end, several important design issues for the guide vane as well as the rotor were thoroughly investigated and accordingly addressed in this paper. A series of computational fluid dynamics (CFD analyses was performed to determine the optimal configuration of the proposed system. Finally, it is demonstrated from performance evaluation tests that the prototype with the specially designed guide vane and rotor for the proposed BIWT system accelerates the wind speed to a sufficient level and consequently increases the power coefficient significantly. Thus, it was confirmed that the proposed system is a promising environment-friendly energy production system for urban areas.

  1. Polychlorinated biphenyl sources, environmental levels, and exposures in school buildings

    Science.gov (United States)

    Background: Building materials and components containing polychlorinated biphenyls (PCBs) were used in some U.S. school buildings until the late 1970s and may be present today. There is limited information on source factors and occupant exposures. Methods: Analysis of PCBs in mat...

  2. Essays in economics of energy efficiency in residential buildings - An empirical analysis[Dissertation 17157

    Energy Technology Data Exchange (ETDEWEB)

    Jakob, M.

    2007-07-01

    Energy efficiency in the building sector is a key element of cost-effective climate change and energy policies in most countries throughout the world. (...) However, a gap between the cost-effectiveness of energy efficiency measures, their benefits, the necessities from a societal point of view on the one hand and the actual investments in the building stock - particularly in the moment of re-investment and refurbishing - on the other hand became more and more evident. The research questions that arose against this background were whether this gap and the low energy efficiency levels and rates could be confirmed empirically and if yes, how the gap could be explained and how it could be overcome by adequate policy measures. To address these questions, the multi-functional character of buildings (i.e. well conditioned and quiet living rooms and working space) had to be considered. Associated benefits arise on the societal level (ancillary benefits) and on the private level (co-benefits), the latter being increasingly addressed by different building labels such as 'Minergie', 'Passive House', and others. It was assumed that these co-benefits are of economic relevance, but empirical evidence regarding their economic value was missing. Thus, putting these benefits into an appropriate economic appraisal framework was at stake to make use of them in market information and policy instruments, preventing uninformed and biased cost benefit analyses and decisions on the private and on the societal level. The research presented in this PhD thesis had the goal to provide a sound empirical basis about costs and benefits of energy efficiency investments in residential buildings, with a special emphasis on the economic valuation of their co-benefits from a building user perspective (owner-occupiers, purchasers and tenants). In view of long time-horizons in the building sector, the techno-economic dynamics should also be addressed. The results should be useful

  3. Structural building screening and evaluation

    Science.gov (United States)

    Kurniawandy, Alex; Nakazawa, Shoji; Hendry, Andy; Ridwan, Firdaus, Rahmatul

    2017-10-01

    An earthquake is a disaster that can be harmful to the community, such as financial loss and also dead injuries. Pekanbaru is a city that located in the middle of Sumatera Island. Even though the city of Pekanbaru is a city that rarely occurs earthquake, but Pekanbaru has ever felt the impact of the big earthquake that occurred in West Sumatera on September 2009. As we know, Indonesia located between Eurasia plate, Pacific plate, and Indo-Australian plate. Particularly the Sumatera Island, It has the Semangko fault or the great Sumatra fault along the island from north to south due to the shift of Eurasia and Indo-Australian Plates. An earthquake is not killing people but the building around the people that could be killing them. The failure of the building can be early prevented by doing an evaluation. In this research, the methods of evaluation have used a guideline for the Federal Emergency Management Agency (FEMA) P-154 and Applied Technology Council (ATC) 40. FEMA P-154 is a rapid visual screening of buildings for potential seismic hazards and ATC-40 is seismic evaluation and retrofit of Concrete Buildings. ATC-40 is a more complex evaluation rather than FEMA P-154. The samples to be evaluated are taken in the surroundings of Universitas Riau facility in Pekanbaru. There are four buildings as case study such as the rent student building, the building of mathematics and natural science faculty, the building teacher training and education faculty and the buildings in the faculty of Social political sciences. Vulnerability for every building facing an earthquake is different, this is depending on structural and non-structural components of the building. Among all of the samples, only the building of mathematics and the natural science faculty is in critical condition according to the FEMA P-154 evaluation. Furthermore, the results of evaluation using ATC-40 for the teacher training building are in damage control conditions, despite the other three buildings are

  4. A Framework for Occupancy Tracking in a Building via Structural Dynamics Sensing of Footstep Vibrations

    Directory of Open Access Journals (Sweden)

    Jeffrey D. Poston

    2017-11-01

    Full Text Available Counting the number of occupants in building areas over time—occupancy tracking—provides valuable information for responding to emergencies, optimizing thermal conditions or managing personnel. This capability is distinct from tracking individual building occupants as they move within a building, has lower complexity than conventional tracking algorithms require, and avoids privacy concerns that tracking individuals may pose. The approach proposed here is a novel combination of data analytics applied to measurements from a building’s structural dynamics sensors (e.g., accelerometers or geophones. Specifically, measurements of footstep-generated structural waves provide evidence of occupancy in a building area. These footstep vibrations can be distinguished from other vibrations, and, once identified, the footsteps can be located. These locations, in turn, form the starting point of estimating occupancy in an area. In order to provide a meaningful occupancy count, however, it is first necessary to associate discrete footsteps with individuals. The proposed framework incorporates a tractable algorithm for this association task. The proposed algorithms operate online, updating occupancy count over time as new footsteps are detected. Experiments with measurements from a public building illustrate the operation of the proposed framework. This approach offers an advantage over others based on conventional technologies by avoiding the cost of a separate sensor system devoted to occupancy tracking.

  5. Electricity Markets, Smart Grids and Smart Buildings

    Science.gov (United States)

    Falcey, Jonathan M.

    A smart grid is an electricity network that accommodates two-way power flows, and utilizes two-way communications and increased measurement, in order to provide more information to customers and aid in the development of a more efficient electricity market. The current electrical network is outdated and has many shortcomings relating to power flows, inefficient electricity markets, generation/supply balance, a lack of information for the consumer and insufficient consumer interaction with electricity markets. Many of these challenges can be addressed with a smart grid, but there remain significant barriers to the implementation of a smart grid. This paper proposes a novel method for the development of a smart grid utilizing a bottom up approach (starting with smart buildings/campuses) with the goal of providing the framework and infrastructure necessary for a smart grid instead of the more traditional approach (installing many smart meters and hoping a smart grid emerges). This novel approach involves combining deterministic and statistical methods in order to accurately estimate building electricity use down to the device level. It provides model users with a cheaper alternative to energy audits and extensive sensor networks (the current methods of quantifying electrical use at this level) which increases their ability to modify energy consumption and respond to price signals The results of this method are promising, but they are still preliminary. As a result, there is still room for improvement. On days when there were no missing or inaccurate data, this approach has R2 of about 0.84, sometimes as high as 0.94 when compared to measured results. However, there were many days where missing data brought overall accuracy down significantly. In addition, the development and implementation of the calibration process is still underway and some functional additions must be made in order to maximize accuracy. The calibration process must be completed before a reliable

  6. An examination of within-session responding following access to reinforcing stimuli.

    Science.gov (United States)

    Rispoli, Mandy; O'Reilly, Mark; Lang, Russell; Machalicek, Wendy; Kang, Soyeon; Davis, Tonya; Neely, Leslie

    2016-01-01

    Previous research has shown tangibly maintained challenging behavior can be temporarily decreased by providing presession access to the relevant tangible. However, the duration of this beneficial effect is unknown. We measured the subsequent duration of behavior reduction effects following presession access during extended classroom observation sessions by analyzing within-session patterns of responding in three children with autism. An alternating treatments design was used to analyze within- and across-session responding following presession access and presession restriction conditions. The cumulative frequency of challenging behavior was higher following the presession restriction condition for all participants and lower following presession access. Within-session analysis revealed the same basic pattern of responding across participants. Specifically, the first half of the sessions contained very little, if any, challenging behavior; however, after 60 min, the rate of challenging behavior began to increase rapidly for two of the three participants. Results are discussed in terms of implications for practitioners, satiation, habituation, and behavioral contrast. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. LDDX: A High Efficiency Air Conditioner for DOD Buildings

    Science.gov (United States)

    2017-02-01

    Additional Benefits ........................................................................................................ 3 1.2.6 Deliverables...inadequate latent cooling can lead building managers to restrict ventilation to minimal levels that further compromise both the comfort and health of...bulb temperatures for outdoor air and return air respectively per ANSI/AHRI Standard 210/240 “Performance Rating of Unitary Air-Conditioning and Air

  8. Treatment Conditions of Building Wastes in China and Its Integrated Management Measures

    Institute of Scientific and Technical Information of China (English)

    Liu Dan; Zha Kun; Li Qibin

    2006-01-01

    The status of utilization and disposal of the building wastes are introduced on the basis of analysis of its compositions, generation and effects on urban environment. The basic framework of the integrated building waste management, including control of the sources, reduction of the integrated process and final disposal, are proposed in view of the problems existing in recovery of the building wastes and the experiences from the developed countries.

  9. How Do Marine Pelagic Species Respond to Climate Change? Theories and Observations

    Science.gov (United States)

    Beaugrand, Grégory; Kirby, Richard R.

    2018-01-01

    In this review, we show how climate affects species, communities, and ecosystems, and why many responses from the species to the biome level originate from the interaction between the species’ ecological niche and changes in the environmental regime in both space and time. We describe a theory that allows us to understand and predict how marine species react to climate-induced changes in ecological conditions, how communities form and are reconfigured, and so how biodiversity is arranged and may respond to climate change. Our study shows that the responses of species to climate change are therefore intelligible—that is, they have a strong deterministic component and can be predicted.

  10. Building Integrated Active Flow Control: Improving the Aerodynamic Performance of Tall Buildings Using Fluid-Based Aerodynamic Modification

    Science.gov (United States)

    Menicovich, David

    respond to fluctuating environmental conditions such as changes in wind direction or velocity over the height of building which could be of consequence if the conditions for which the building was designed for change due to, for example, changes in the built environment surrounding it. Fluidic-based Aerodynamic Modification (FAM) is a fundamentally different approach; instead of adjusting the solid material to improve the aerodynamic 'shape' of the structure, fluid-based flow control is used to manipulate the boundary layer characteristics. The local flow field is modified to 'view' the solid as a different shape, and thus, that solid will experience reduced loads.

  11. HACCP-Based Programs for Preventing Disease and Injury from Premise Plumbing: A Building Consensus

    Directory of Open Access Journals (Sweden)

    William F. McCoy

    2015-07-01

    Full Text Available Thousands of preventable injuries and deaths are annually caused by microbial, chemical and physical hazards from building water systems. Water is processed in buildings before use; this can degrade the quality of the water. Processing steps undertaken on-site in buildings often include conditioning, filtering, storing, heating, cooling, pressure regulation and distribution through fixtures that restrict flow and temperature. Therefore, prevention of disease and injury requires process management. A process management framework for buildings is the hazard analysis and critical control point (HACCP adaptation of failure mode effects analysis (FMEA. It has been proven effective for building water system management. Validation is proof that hazards have been controlled under operating conditions and may include many kinds of evidence including cultures of building water samples to detect and enumerate potentially pathogenic microorganisms. However, results from culture tests are often inappropriately used because the accuracy and precision are not sufficient to support specifications for control limit or action triggers. A reliable negative screen is based on genus-level Polymerase Chain Reaction (PCR for Legionella in building water systems; however, building water samples with positive results from this test require further analysis by culture methods.

  12. HACCP-Based Programs for Preventing Disease and Injury from Premise Plumbing: A Building Consensus

    Science.gov (United States)

    McCoy, William F.; Rosenblatt, Aaron A.

    2015-01-01

    Thousands of preventable injuries and deaths are annually caused by microbial, chemical and physical hazards from building water systems. Water is processed in buildings before use; this can degrade the quality of the water. Processing steps undertaken on-site in buildings often include conditioning, filtering, storing, heating, cooling, pressure regulation and distribution through fixtures that restrict flow and temperature. Therefore, prevention of disease and injury requires process management. A process management framework for buildings is the hazard analysis and critical control point (HACCP) adaptation of failure mode effects analysis (FMEA). It has been proven effective for building water system management. Validation is proof that hazards have been controlled under operating conditions and may include many kinds of evidence including cultures of building water samples to detect and enumerate potentially pathogenic microorganisms. However, results from culture tests are often inappropriately used because the accuracy and precision are not sufficient to support specifications for control limit or action triggers. A reliable negative screen is based on genus-level Polymerase Chain Reaction (PCR) for Legionella in building water systems; however, building water samples with positive results from this test require further analysis by culture methods. PMID:26184325

  13. The homeostasis solution – Mechanical homeostasis in architecturally homeostatic buildings

    International Nuclear Information System (INIS)

    Wang, Lin-Shu; Ma, Peizheng

    2016-01-01

    Highlights: • Architectural homeostatic buildings (AHBs) make sense because of the laws of physics. • However, high efficiency can be obtained only with AHBs and equipment considered as systems. • Mechanical homeostasis facilitates AHB-equipment system synergy with heat extraction. • Entropically speaking a building needs neither energy nor a fixed amount of heat, but its homeostatic existence. • Homeostatic buildings can reduce building energy consumption from 80% to 90%. - Abstract: We already know, for energy-saving potential, the necessary architectural features in well-designed buildings: high performance building envelope, sufficient interior thermal mass, and hydronic-network activated radiant surfaces for cooling and heating. Buildings with these features may be referred to as architecturally homeostatic buildings (AHBs); such a building-system is thermally semi-autonomous in the sense that its temperature variation stays within a certain range even without conditioning equipment, and, with conditioning equipment in operation, its thermal regulation is handled by its hydronic heat-distribution-network for controlling the temperature level of the building. At the present time conventional HVAC equipment is used for maintaining the heat-distribution-network: this arrangement, however, has resulted in great energy saving only for AHBs with accessible natural water bodies. In operation of general AHBs, a case is made here for a new kind of mechanical equipment having the attribute of mechanical homeostasis (MH). MH is a new energy transformation concept in a triadic framework. Superlative energy efficiency is predicted as a result of combined improvements in higher triadCOPs and lower total (inducted + removed) heat rates—evincing existence of synergy in architectural and mechanical homeostasis, which together will be referred to as the homeostasis solution.

  14. Design/installation and structural integrity assessment under the Federal Facility Agreement for Bethel Valley Low-Level Waste Collection and Transfer System upgrade for Building 2026 (High Radiation Level Analytical Laboratory) and Building 2099 (Monitoring and Control Station) at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    1994-10-01

    This document presents a Design/Installation and Structural Integrity Assessment for a replacement tank system for portions of the Bethel Valley Low Level Waste (LLW) System, located at the Oak Ridge Reservation, Oak Ridge, Tennessee. This issue of the assessment covers the design aspects of the replacement tank system, and certifies that the design has sufficient structural integrity and is acceptable for the storing or treating of hazardous and/or radioactive substances. The present issue identifies specific activities that must be completed during the fabrication, installation, and testing of the replacement tank system in order to provide assurance that the final installation complies with governing requirements. Portions of the LLW system are several decades old, or older, and do not comply with current environmental protection regulations. Several subsystems of the LLW system have been designated to receive a state-of-the-art replacement and refurbishment. One such subsystem serves Building 2026, the High Radiation Level Analytical Laboratory. This assessment focuses on the scope of work for the Building 2026 replacement LLW Collection and Transfer System, including the provision of a new Monitoring and Control Station (Building 2099) to receive, store, and treat (adjust pH) low level radioactive waste

  15. Future Green Buildings

    DEFF Research Database (Denmark)

    Mathiesen, Brian Vad; Drysdale, David; Lund, Henrik

    an energy system integration perspective, heat savings, electricity savings, and user behavioural aspects as well as energy storage and household level flexibility. Many reports on green or sustainable buildings focus only on savings levels and disregard the cost of renewable energy production. Some reports......Efficient buildings are essential for an affordable Danish energy supply in 2050. The purpose of this report is to describe the contribution and role of the building sector in a 100% renewable energy future, as well as the transitions that are necessary in the building sector to support this change....... The report builds on a literature review encompassing more than 50 reports and research papers over the last 10 years and more than a two decades knowledge about the interactions between different components of the energy sector. The review has been focused on aspects such as cost-effective solutions from...

  16. The effects of nicotine exposure during Pavlovian conditioning in rats on several measures of incentive motivation for a conditioned stimulus paired with water.

    Science.gov (United States)

    Guy, Elizabeth Glenn; Fletcher, Paul J

    2014-06-01

    Nicotine enhances approach toward and operant responding for conditioned stimuli (CSs), but the effect of exposure during different phases of Pavlovian incentive learning on these measures remains to be determined. These studies examined the effects of administering nicotine early, late or throughout Pavlovian conditioning trials on discriminated approach behavior, nicotine-enhanced responding for conditioned reinforcement, extinction, and the reinstatement of responding for conditioned reinforcement. We also tested the effect of nicotine on approach to a lever-CS in a Pavlovian autoshaping procedure and for this CS to serve as a conditioned reinforcer. Thirsty rats were exposed to 13 conditioning sessions where a light/tone CS was paired with the delivery of water. Nicotine was administered either prior to the first or last seven sessions, or throughout the entire conditioning procedure. Responding for conditioned reinforcement, extinction, and the reinstatement of responding by the stimulus and nicotine were compared across exposure groups. Separately, the effects of nicotine on conditioned approach toward a lever-CS during autoshaping, and responding for that CS as a conditioned reinforcer, were examined. Nicotine exposure was necessary for nicotine-enhanced responding for conditioned reinforcement and the ability for nicotine and the stimulus to additively reinstate responding on the reinforced lever. Nicotine increased contacts with a lever-CS during autoshaping, and removal of nicotine abolished this effect. Prior nicotine exposure was necessary for nicotine-enhanced responding reinforced by the lever. Enhancements in the motivating properties of CSs by nicotine occur independently from duration and timing effects of nicotine exposure during conditioning.

  17. New opportunities for ventilation assistance in buildings under Saharan climatic conditions

    Directory of Open Access Journals (Sweden)

    Kaoulal Rabea

    2017-01-01

    Full Text Available The aim of this paper is devoted to the coupling of ventilation systems with buildings with low energy performances under a specific Saharan climate. In the second part, the objective is to diagnose and quantify energy consumptions due to the ventilation of a real residential building in Ghardaia site. As result, ventilation system can bring a positive support to the thermos-aeraulic comfort by controlling the mass flow rate of the air entering to the heated or/and cooled building zone. Heat losses due to the ventilation system represent 4.75% of the total losses; the provided heat exchange in this case requires an additional consumption of around 6.6058% of the total energy needs.

  18. Conditions of contract for construction for building and engineering works designed by the employer : general conditions : guidance for the preparation of particular conditions forms of letter of tender, contract agreement and dispute adjudication agreement

    CERN Document Server

    1999-01-01

    Conditions of Contract for Construction, which are recommended for building or engineering works designed by the Employer or by his representative, the Engineer. Under the usual arrangements for this type of contract, the Contractor constructs the works in accordance with a design provided by the Employer. However, the works may include some elements of Contractor-designed civil, mechanical, electrical and/or construction works.

  19. Interior insulation – Experimental investigation of hygrothermal conditions and damage evaluation of solid masonry façades in a listed building

    DEFF Research Database (Denmark)

    Odgaard, Tommy; Bjarløv, Søren Peter; Rode, Carsten

    2018-01-01

    Exterior walls in historic multi-storey buildings compared to walls in modern buildings have low thermal resistance, resulting in high energy loss and cold surfaces/floors in cold climates. When restrictions regarding alteration of the exterior appearance exist, interior insulation might be the o......Exterior walls in historic multi-storey buildings compared to walls in modern buildings have low thermal resistance, resulting in high energy loss and cold surfaces/floors in cold climates. When restrictions regarding alteration of the exterior appearance exist, interior insulation might...... be the only possibility to increase occupant comfort. This paper describes an investigation of the hygrothermal influence when applying 100 mm of diffusion open interior insulation to a historic multi-storey solid masonry spandrel. The dormitory room with the insulated spandrel had a normal indoor climate...... showed no risk of damage from the changed hygrothermal conditions when applying interior insulation to a solid masonry spandrel....

  20. Automatic Generation of Building Models with Levels of Detail 1-3

    Science.gov (United States)

    Nguatem, W.; Drauschke, M.; Mayer, H.

    2016-06-01

    We present a workflow for the automatic generation of building models with levels of detail (LOD) 1 to 3 according to the CityGML standard (Gröger et al., 2012). We start with orienting unsorted image sets employing (Mayer et al., 2012), we compute depth maps using semi-global matching (SGM) (Hirschmüller, 2008), and fuse these depth maps to reconstruct dense 3D point clouds (Kuhn et al., 2014). Based on planes segmented from these point clouds, we have developed a stochastic method for roof model selection (Nguatem et al., 2013) and window model selection (Nguatem et al., 2014). We demonstrate our workflow up to the export into CityGML.

  1. Costs of radon diagnostics and mitigation in school building

    International Nuclear Information System (INIS)

    Leovic, K.W.; Rector, H.; Nagda, N.

    1992-01-01

    To determine the costs of radon diagnostics and active soil depressurization (ASD) system installation in schools, seven radon mitigators with extensive experience in school buildings were surveyed. The cost data were determined by providing the mitigators with two scenarios of open-quotes typicalclose quotes school buildings with elevated radon levels. The questionnaire in schools: (1) Review Construction Plans, (2) Conduct Diagnostic Measurements, (3) Design Mitigation System, (4) Purchase ASD Material, and (5) Install and Checkout ASD System. Based on the results of this survey, it is estimated that the average cost of ASD diagnostics and mitigation in a typical school would be roughly $0.50 per ft 2 . However, these costs would be higher in schools with extensive subslab walls, very poor PFE, and lower in simple schools with very good PFE and no subslab barriers to communication. The variations in costs provided by the mitigators are primarily due to the influences of (1) experience and practices of the mitigation companies, (2) ASD system requirements as perceived by the respondents, and (3) the degree of involvement by the school system in the process

  2. Model calibration for building energy efficiency simulation

    International Nuclear Information System (INIS)

    Mustafaraj, Giorgio; Marini, Dashamir; Costa, Andrea; Keane, Marcus

    2014-01-01

    Highlights: • Developing a 3D model relating to building architecture, occupancy and HVAC operation. • Two calibration stages developed, final model providing accurate results. • Using an onsite weather station for generating the weather data file in EnergyPlus. • Predicting thermal behaviour of underfloor heating, heat pump and natural ventilation. • Monthly energy saving opportunities related to heat pump of 20–27% was identified. - Abstract: This research work deals with an Environmental Research Institute (ERI) building where an underfloor heating system and natural ventilation are the main systems used to maintain comfort condition throughout 80% of the building areas. Firstly, this work involved developing a 3D model relating to building architecture, occupancy and HVAC operation. Secondly, the calibration methodology, which consists of two levels, was then applied in order to insure accuracy and reduce the likelihood of errors. To further improve the accuracy of calibration a historical weather data file related to year 2011, was created from the on-site local weather station of ERI building. After applying the second level of calibration process, the values of Mean bias Error (MBE) and Cumulative Variation of Root Mean Squared Error (CV(RMSE)) on hourly based analysis for heat pump electricity consumption varied within the following ranges: (MBE) hourly from −5.6% to 7.5% and CV(RMSE) hourly from 7.3% to 25.1%. Finally, the building was simulated with EnergyPlus to identify further possibilities of energy savings supplied by a water to water heat pump to underfloor heating system. It found that electricity consumption savings from the heat pump can vary between 20% and 27% on monthly bases

  3. Wind turbine blades condition assessment based on vibration measurements and the level of an empirically decomposed feature

    International Nuclear Information System (INIS)

    Abouhnik, Abdelnasser; Albarbar, Alhussein

    2012-01-01

    Highlights: ► We used finite element method to model wind turbine induced vibration characteristics. ► We developed a technique for eliminating wind turbine’s vibration modulation problems. ► We use empirical mode decomposition to decompose the vibration into its fundamental elements. ► We show the area under shaft speed is a good indicator for assessing wind blades condition. ► We validate the technique under different wind turbine speeds and blade (cracks) conditions. - Abstract: Vibration based monitoring techniques are well understood and widely adopted for monitoring the condition of rotating machinery. However, in the case of wind turbines the measured vibration is complex due to the high number of vibration sources and modulation phenomenon. Therefore, extracting condition related information of a specific element e.g. blade condition is very difficult. In the work presented in this paper wind turbine vibration sources are outlined and then a three bladed wind turbine vibration was simulated by building its model in the ANSYS finite element program. Dynamic analysis was performed and the fundamental vibration characteristics were extracted under two healthy blades and one blade with one of four cracks introduced. The cracks were of length (10 mm, 20 mm, 30 mm and 40 mm), all had a consistent 3 mm width and 2 mm depth. The tests were carried out for three rotation speeds; 150, 250 and 360 r/min. The effects of the seeded faults were revealed by using a novel approach called empirically decomposed feature intensity level (EDFIL). The developed EDFIL algorithm is based on decomposing the measured vibration into its fundamental components and then determines the shaft rotational speed amplitude. A real model of the simulated wind turbine was constructed and the simulation outcomes were compared with real-time vibration measurements. The cracks were seeded sequentially in one of the blades and their presence and severity were determined by decomposing

  4. Wireless sensor network performance metrics for building applications

    Energy Technology Data Exchange (ETDEWEB)

    Jang, W.S. (Department of Civil Engineering Yeungnam University 214-1 Dae-Dong, Gyeongsan-Si Gyeongsangbuk-Do 712-749 South Korea); Healy, W.M. [Building and Fire Research Laboratory, 100 Bureau Drive, Gaithersburg, MD 20899-8632 (United States)

    2010-06-15

    Metrics are investigated to help assess the performance of wireless sensors in buildings. Wireless sensor networks present tremendous opportunities for energy savings and improvement in occupant comfort in buildings by making data about conditions and equipment more readily available. A key barrier to their adoption, however, is the uncertainty among users regarding the reliability of the wireless links through building construction. Tests were carried out that examined three performance metrics as a function of transmitter-receiver separation distance, transmitter power level, and obstruction type. These tests demonstrated, via the packet delivery rate, a clear transition from reliable to unreliable communications at different separation distances. While the packet delivery rate is difficult to measure in actual applications, the received signal strength indication correlated well with the drop in packet delivery rate in the relatively noise-free environment used in these tests. The concept of an equivalent distance was introduced to translate the range of reliability in open field operation to that seen in a typical building, thereby providing wireless system designers a rough estimate of the necessary spacing between sensor nodes in building applications. It is anticipated that the availability of straightforward metrics on the range of wireless sensors in buildings will enable more widespread sensing in buildings for improved control and fault detection. (author)

  5. Intervention strategies for energy efficient municipal buildings: Influencing energy decisions throughout buildings` lifetimes

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-12-31

    The current energy-related decisionmaking processes that take place during the lifetimes of municipal buildings in San Francisco do not reflect our ideal picture of energy efficiency as a part of staff awareness and standard practice. Two key problems that undermine the success of energy efficiency programs are lost opportunities and incomplete actions. These problems can be caused by technology-related issues, but often the causes are institutional barriers (organizational or procedural {open_quotes}people problems{close_quotes}). Energy efficient decisions are not being made because of a lack of awareness or policy mandate, or because financial resources are not available to decisionmakers. The Bureau of Energy Conservation (BEC) is working to solve such problems in the City & County of San Francisco through the Intervention Strategies project. In the first phase of the project, using the framework of the building lifetime, we learned how energy efficiency in San Francisco municipal buildings can be influenced through delivering services to support decisionmakers; at key points in the process of funding, designing, constructing and maintaining them. The second phase of the project involved choosing and implementing five pilot projects. Through staff interviews, we learned how decisions that impact energy use are made at various levels. We compiled information about city staff and their needs, and resources available to meet those needs. We then designed actions to deliver appropriate services to staff at these key access points. BEC implemented five pilot projects corresponding to various stages in the building`s lifetime. These were: Bond Guidelines, Energy Efficient Design Practices, Commissioning, Motor Efficiency, and Facilities Condition Monitoring Program.

  6. Building a Unit-Level Mentored Program to Sustain a Culture of Inquiry for Evidence-Based Practice

    Science.gov (United States)

    2015-03-24

    Melnyk and Eileen Fineout-Overholt, who graciously and consistently support military nursing science. Building a Unit-Level Mentored Program...Rosenberg W, Gray JA, Haynes RB, Richardson WS. Evidence based medicine: What it is and what it isn’t. BMJ. 1996;312(7023):71-72.doi: http

  7. AP1000 Shield Building Dynamic Response for Different Water Levels of PCCWST Subjected to Seismic Loading considering FSI

    Directory of Open Access Journals (Sweden)

    Daogang Lu

    2015-01-01

    Full Text Available Huge water storage tank on the top of many buildings may affect the safety of the structure caused by fluid-structure interaction (FSI under the earthquake. AP1000 passive containment cooling system water storage tank (PCCWST placed at the top of shield building is a key component to ensure the safety of nuclear facilities. Under seismic loading, water will impact the wall of PCCWST, which may pose a threat to the integrity of the shield building. In the present study, an FE model of AP1000 shield building is built for the modal and transient seismic analysis considering the FSI. Six different water levels in PCCWST were discussed by comparing the modal frequency, seismic acceleration response, and von Mises stress distribution. The results show the maximum von Mises stress emerges at the joint of shield building roof and water around the air inlet. However, the maximum von Mises stress is below the yield strength of reinforced concrete. The results may provide a reference for design of the AP1000 and CAP1400 in the future.

  8. THE COMPARISON BETWEEN COMPUTER SIMULATION AND PHYSICAL MODEL IN CALCULATING ILLUMINANCE LEVEL OF ATRIUM BUILDING

    Directory of Open Access Journals (Sweden)

    Sushardjanti Felasari

    2003-01-01

    Full Text Available This research examines the accuracy of computer programmes to simulate the illuminance level in atrium buildings compare to the measurement of those in physical models. The case was taken in atrium building with 4 types of roof i.e. pitched roof, barrel vault roof, monitor pitched roof (both monitor pitched roof and monitor barrel vault roof, and north light roof (both with north orientation and south orientation. The results show that both methods have agreement and disagreement. They show the same pattern of daylight distribution. In the other side, in terms of daylight factors, computer simulation tends to underestimate calculation compared to physical model measurement, while for average and minimum illumination, it tends to overestimate the calculation.

  9. Building envelope regulations on thermal comfort in glass facade buildings and energy-saving potential for PMV-based comfort control

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Ruey-Lung; Shu, Shiu-Ya [Department of Architecture, National United University, 1, Lien-Da, Kung-Ching Li, Miaoli, 36003 (China)

    2011-04-15

    This paper presents an investigation of the effect of building envelope regulation on thermal comfort and on the energy-saving potential for PMV-based comfort control in glass facade buildings. Occurrences and severity of overheating, based on the PMV-PPD model contained in ISO 7730, were used for the thermal comfort assessment. Parametric study simulations for an actual building with a large glass facade were carried out to predict the changes in thermal comfort levels in a space due to different glazing types, depths of overhang and glazing areas, which are the key parameters of the building envelope regulation index, named ENVLOAD, in Taiwan. The result demonstrates that the ENVLOAD has significant effect on thermal comfort. Additionally, comparative simulations between PMV-based comfort control and conventional thermostatic control were performed to investigate the changes in the energy-saving potential of a thermal comfort-controlled space due to changes of its ENVLOAD. The results demonstrate that the energy-saving potential in a PMV-based controlled space increases with low ENVLOAD conditions. (author)

  10. Building America Residential System Research Results: Achieving 30% Whole House Energy Savings Level in Cold Climates

    Energy Technology Data Exchange (ETDEWEB)

    Building Industry Research Alliance (BIRA); Building Science Consortium (BSC); Consortium for Advanced Residential Buildings (CARB); Florida Solar Energy Center (FSEC); IBACOS; National Renewable Energy Laboratory (NREL)

    2006-08-01

    The Building America program conducts the system research required to reduce risks associated with the design and construction of homes that use an average of 30% to 90% less total energy for all residential energy uses than the Building America Research Benchmark, including research on homes that will use zero net energy on annual basis. To measure the program's progress, annual research milestones have been established for five major climate regions in the United States. The system research activities required to reach each milestone take from 3 to 5 years to complete and include research in individual test houses, studies in pre-production prototypes, and research studies with lead builders that provide early examples that the specified energy savings level can be successfully achieved on a production basis. This report summarizes research results for the 30% energy savings level and demonstrates that lead builders can successfully provide 30% homes in Cold Climates on a cost-neutral basis.

  11. The performance of energy efficient residential building envelope systems

    Energy Technology Data Exchange (ETDEWEB)

    Proskiw, G.

    1996-08-01

    The adequacy and durability of residential building envelope systems under actual field conditions were evaluated. A building envelope offers protection from cold, heat, moisture, wind and noise. However, they are exposed to thermal, structural, and moisture stresses and their performance can degrade over time. Envelope performance was evaluated at 20 energy efficient and four conventional, detached modern homes in Winnipeg, Canada. The three complementary measurement tools were wood moisture content (WMC) of framing members, thermographic examinations, and airtightness tests. As expected, energy efficient building envelope systems performed better than the conventional systems. No evidence of envelope degradation was found in any of the energy efficient houses. The building envelopes using polyethylene air barriers performed slightly better than those which used the airtight drywall approach, although both were considered satisfactory. WMC levels were a bit lower in the polyethylene-clad house. 1 ref., 1 tab.

  12. Optimal choice: assessing the probability of additional damage to buildings caused by water level changes of larger areas

    Science.gov (United States)

    Bijnagte, J. L.; Luger, D.

    2012-12-01

    In the Northern parts of the Netherlands exploration of natural gas reservoirs causes subsidence over large areas. As a consequence, the water levels in canals and polders have to be adjusted over time in order to keep the groundwater levels at a constant depth relative to the surface level. In the middle of the subsidence area it is relatively easy to follow the settlements by a uniform lowering of the water level. This would however result in a relative lowering of the groundwater table at the edges of the subsidence area. Given the presence of soft compressible soils, this would result in induced settlements. For buildings in these areas this will increase the chance of damage. A major design challenge lies therefore in the optimisation of the use of compartments. The more compartments the higher the cost therefore the aim is to make compartments in the water management system that are as large as possible without causing inadmissible damage to buildings. In order to asses expected damage from different use of compartments three tools are needed. The first is a generally accepted method of damage determination, the second a method to determine the contribution to damage of a new influence, e.g. a groundwater table change. Third, and perhaps most importantly, a method is needed to evaluate effects not for single buildings but for larger areas. The first need is covered by established damage criteria like those of Burland & Wroth or Boscardin & Cording. Up until now the second and the third have been problematic. This paper presents a method which enables to assign a contribution to the probability of damage of various recognised mechanisms such as soil and foundation inhomogeneity, uneven loading, ground water level changes. Shallow subsidence due to peat oxidation and deep subsidence due to reservoir depletion can be combined. In order to address the third issue: evaluation of effects for larger areas, the method uses a probabilistic approach. Apart from a

  13. Responding to the challenge of antimalarial drug resistance by routine monitoring to update national malaria treatment policies

    DEFF Research Database (Denmark)

    Vestergaard, Lasse S; Ringwald, Pascal

    2007-01-01

    of rational and updated malaria treatment policies, but defining and updating such policies requires a sufficient volume of high-quality drug-resistance data collected at national and regional levels. Three main tools are used for drug resistance monitoring, including therapeutic efficacy tests, in vitro...... additional information about changing patterns of resistance. However, some of the tests are technically demanding, and thus there is a need for more resources for training and capacity building in endemic countries to be able to adequately respond to the challenge of drug resistance.......Reduced sensitivity of Plasmodium falciparum to formerly recommended cheap and well-known antimalarial drugs places an increasing burden on malaria control programs and national health systems in endemic countries. The high costs of the new artemisinin-based combination treatments underline the use...

  14. Low air exchange rate causes high indoor radon concentration in energy-efficient buildings

    International Nuclear Information System (INIS)

    Vasilyev, A.V.; Yarmoshenko, I.V.; Zhukovsky, M.V.

    2015-01-01

    Since 1995, requirements on energy-efficient building construction were established in Russian Building Codes. In the course of time, utilisation of such technologies became prevailing, especially in multi-storey building construction. According to the results of radon survey in buildings constructed meeting new requirements on energy efficiency, radon concentration exceeds the average level in early-constructed buildings. Preponderance of the diffusion mechanism of radon entry in modern multi-storey buildings has been experimentally established. The experimental technique of the assessment of ventilation rate in dwellings under real conditions was developed. Based on estimates of average ventilation rate, it was approved that measures to increase energy efficiency lead to reduction in ventilation rate and accumulation of higher radon concentrations indoors. Obtained ventilation rate values have to be considered as extremely low. (authors)

  15. Discriminant cognitive factors in responder and non-responder patients with schizophrenia.

    Science.gov (United States)

    Stip, E; Lussier, I; Ngan, E; Mendrek, A; Liddle, P

    1999-12-01

    To identify which improvements in cognitive function are associated with symptom resolution in schizophrenic patients treated with atypical antipsychotics. a prospective open trial with atypical neuroleptics (risperidone, clozapine, quetiapine). Inpatient and outpatient units, Institute of Psychiatry. Thirty-nine patients with schizophrenia according to DSM-IV criteria were included. Clinical and cognitive assessment were done at baseline (T0) and again after six months of treatment (T2). Twenty-five patients completed the trial. New-generation antipsychotics during six months. Patients were considered as responders if their PANSS score decreased at least 20% (n = 15) and non-responders if it did not (n = 10). a computerized cognitive assessment comprised tests of short-term-memory (digit span), explicit long-term memory (word pair learning), divided attention, selective attention and verbal fluency (orthographic and semantic). Clinical assessment included PANSS and ESRS. A discriminant function analysis was performed to determine which changes in cognitive performance predicted symptomatic response status. Semantic fluency and orthographic fluency were significant predictors. Together they correctly predicted responder status in 88% of cases. Memory was not a significant predictor of symptomatic response. Verbal fluency discriminated the responder from the non-responder group during a pharmacological treatment.

  16. Prismatic louver active façades for natural illumination and thermal energy gain in high-rise and commercial buildings

    Science.gov (United States)

    Vlachokostas, A.; Volkmann, C.; Madamopoulos, N.

    2013-06-01

    High-rise and commercial buildings in urban centers present a great challenge in terms of their energy consumption. Due to maximization of rentable square footage, the preferred urban façade system over the past 50 years has been the "curtain wall", only a few inches thick and comprised of modular steel or aluminum framing and predominant glass infills. The perceived Achilles heel of these modern glass façade systems is their thermal inefficiency: They are inadequate thermal barriers and exhibit excessive solar gain. The excessive solar gain has a negative impact on lighting and cooling loads of the entire building. This negative impact will be further exacerbated with rising energy costs. However, rather than view the glass façade's uncontrolled solar gain merely as a weakness contributing to higher energy consumption, the condition could indeed be considered as related to an energy solution. These glass façades can be retrofitted to operate as a provider of daylight and energy for the rest of the building, taking advantage of the overexposure to the sun. With today's technology, the sun's abundant renewable energy can be the driving force for the energy transition of these building envelopes. Illumination, thermal energy, and electricity production can be directly supplied from the sun, and when correctly and efficiently managed, they can lead to a significantly less energy-intensive building stock. We propose a multi-purpose, prismatic, louver-based façade to perform both daylight and thermal energy harvesting with a goal of offering a better daylight environment for the occupants, and reduce the energy consumption and carbon footprint of the building. While decentralized air-conditioning units are commonly accepted as façade "plug-ins", such decentralization could be utilized with more benefits by passively managing the interior space conditions, without using any extra power. Just as living organisms respond and adapt to the environmental changes in

  17. Analysis of variables that influence electric energy consumption in commercial buildings in Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, M.M.Q. [Technical Drawing Department, Fluminense Federal University, Niteroi, Rio de Janeiro (Brazil); Energy Planning Program, Alberto Luiz Coimbra Institute for Research and Graduate Studies in Engineering - COPPE, Federal University of Rio de Janeiro, Rio de Janeiro (Brazil); La Rovere, E.L. [Energy Planning Program, Alberto Luiz Coimbra Institute for Research and Graduate Studies in Engineering - COPPE, Federal University of Rio de Janeiro, Rio de Janeiro (Brazil); Goncalves, A.C.M. [Program for Graduate Studies in Architecture, School of Architecture and Urbanism, Federal University of Rio de Janeiro, Rio de Janeiro (Brazil)

    2010-12-15

    Air conditioning systems in commercial buildings in Brazil are responsible for about 70% share of their energy consumption. According to BEN 2009 (The Brazilian Energy Balance), energy consumption in the residential, commercial and public sectors, where most buildings are found, represents 9.3% of the final energy consumption in Brazil. This paper aims to examine design factors that could contribute to greater reductions of electric energy consumption in commercial buildings, with emphasis on air conditioning. Simulations were carried out using shades and different types of glass, walls, flooring and roofing. The VisualDOE 2.61 was used as a simulation tool for calculating energy consumption of the analyzed building. This paper shows that the energy performance of the building is considerably influenced by the facade protection and shows, through tables, the impact that decisions related to the top-level and facades have on the energy consumption of the building. The authors concluded that the results confirm the importance of taking energy use into account in the very first design stages of the project, since appropriate choices of types of glass, external shading and envelope materials have a significant impact on energy consumption. (author)

  18. The Effect of Educational Attainment on the Job Satisfaction Level of Correctional Officers.

    Science.gov (United States)

    1979-01-01

    psychological , physiological, and environmental circum- stances that causes a person to say I am satisfied with my job." While this definition may...physical and psychological conditions in their work place. Finally, there are the "extrinsic" satisfactions derived from the tangible rewards that...Table 5. Respondents’ Work Alienation Levels Levelsa Percentage Low 44.0 Moderate 29.6 High 26.4 aLevels of alienation are inferred from the respondents

  19. [Preventive effects of sound insulation windows on the indoor noise levels in a street residential building in Beijing].

    Science.gov (United States)

    Guo, Bin; Huang, Jing; Guo, Xin-biao

    2015-06-18

    To evaluate the preventive effects of sound insulation windows on traffic noise. Indoor noise levels of the residential rooms (on both the North 4th ring road side and the campus side) with closed sound insulation windows were measured using the sound level meter, and comparisons with the simultaneously measured outdoor noise levels were made. In addition, differences of indoor noise levels between rooms with closed sound insulation windows and open sound insulation windows were also compared. The average outdoor noise levels of the North 4th ring road was higher than 70 dB(A), which exceeded the limitation stated in the "Environmental Quality Standard for Noise" (GB 3096-2008) in our country. However, with the sound insulation windows closed, the indoor noise levels reduced significantly to the level under 35 dB(A) (Pwindows had significant influence on the indoor noise levels (Pwindow, when the sound insulation windows were closed, the indoor noise levels reduced 18.8 dB(A) and 8.3 dB(A) in residential rooms facing North 4th ring road side and campus side, respectively. The results indicated that installation of insulation windows had significant noise reduction effects on street residential buildings especially on the rooms facing major traffic roads. Installation of the sound insulation windows has significant preventive effects on indoor noise in the street residential building.

  20. THE FORMATION OF THE COMPETITIVENESS OF THE ENTERPRISES OF MACHINE-BUILDING COMPLEX OF UKRAINE

    Directory of Open Access Journals (Sweden)

    Oksana Zbyrannyk

    2016-11-01

    Full Text Available The purpose is to analyse the existing approaches to determine the value of the production of innovative products and innovation in enterprises of machine-building complex of Ukraine in order to improve their level of competitiveness. Methodology. Statistical analysis and generalization of scientific approaches to the formation of the competitiveness of machine-building enterprises. Results of the of the analyzed approaches allowed to identify the cause of the imperfection of innovation policy in engineering. According to the research, the number of machine-building enterprises engaged in innovation activity, constantly shrinks; the share of innovative products in the total is only 3.5-4%, and the volume of imports of high-tech products exceeding the size of own production; the level of knowledge-intensive industrial production is only 0.3%. All this slows down the process of creating competitive products and as a result, the failure to provide highly own products to other industries, take a niche world of mechanical engineering. Practical implications. Ensure accelerated economic growth of the country as the defining condition for implementation of the European integration aspirations of Ukraine in the short term requires the intensification of innovative activity of the machine-building enterprises. The current state of innovation activity of enterprises in Ukraine is characterized by a number of negative factors: the internal environment of the majority of machine-building enterprises does not correspond to the market conditions of managing: high energy productions, the growth of the degree of wear and tear of fixed assets and reduce investment to update them, the lack of introduction of advanced production and resource-saving technologies, reducing innovation activity due to lack of financial resources significantly affect the level of the competitive machine-building enterprises. Value/ originality systematic approaches to determining the

  1. Tools for Performance Simulation of Heat, Air and Moisture Conditions of Whole Buildings

    DEFF Research Database (Denmark)

    Woloszyn, Monika; Rode, Carsten

    2008-01-01

    Humidity of indoor air is an important factor influencing the air quality and energy consumption of buildings as well as durability of building components. Indoor humidity depends on several factors, such as moisture sources, air change, sorption in materials and possible condensation. Since all...... and moisture transfer processes that take place in “whole buildings” by considering all relevant parts of its constituents. It is believed that full understanding of these processes for the whole building is absolutely crucial for future energy optimization of buildings, as this cannot take place without...

  2. Responding to Sea Level Rise: Does Short-Term Risk Reduction Inhibit Successful Long-Term Adaptation?

    Science.gov (United States)

    Keeler, A. G.; McNamara, D. E.; Irish, J. L.

    2018-04-01

    Most existing coastal climate-adaptation planning processes, and the research supporting them, tightly focus on how to use land use planning, policy tools, and infrastructure spending to reduce risks from rising seas and changing storm conditions. While central to community response to sea level rise, we argue that the exclusive nature of this focus biases against and delays decisions to take more discontinuous, yet proactive, actions to adapt—for example, relocation and aggressive individual protection investments. Public policies should anticipate real estate market responses to risk reduction to avoid large costs—social and financial—when and if sea level rise and other climate-related factors elevate the risks to such high levels that discontinuous responses become the least bad alternative.

  3. Superlattice band structure: New and simple energy quantification condition

    Energy Technology Data Exchange (ETDEWEB)

    Maiz, F., E-mail: fethimaiz@gmail.com [University of Cartage, Nabeul Engineering Preparatory Institute, Merazka, 8000 Nabeul (Tunisia); King Khalid University, Faculty of Science, Physics Department, P.O. Box 9004, Abha 61413 (Saudi Arabia)

    2014-10-01

    Assuming an approximated effective mass and using Bastard's boundary conditions, a simple method is used to calculate the subband structure for periodic semiconducting heterostructures. Our method consists to derive and solve the energy quantification condition (EQC), this is a simple real equation, composed of trigonometric and hyperbolic functions, and does not need any programming effort or sophistic machine to solve it. For less than ten wells heterostructures, we have derived and simplified the energy quantification conditions. The subband is build point by point; each point presents an energy level. Our simple energy quantification condition is used to calculate the subband structure of the GaAs/Ga{sub 0.5}Al{sub 0.5}As heterostructures, and build its subband point by point for 4 and 20 wells. Our finding shows a good agreement with previously published results.

  4. Projected atoll shoreline and run-up changes in response to sea-level rise and varying large wave conditions at Wake and Midway Atolls, Northwestern Hawaiian Islands

    Science.gov (United States)

    Shope, James B.; Storlazzi, Curt; Hoeke, Ron

    2017-01-01

    Atoll islands are dynamic features that respond to seasonal alterations in wave conditions and sea level. It is unclear how shoreline wave run-up and erosion patterns along these low elevation islands will respond to projected sea-level rise (SLR) and changes in wave climate over the next century, hindering communities' preparation for the future. To elucidate how these processes may respond to climate change, extreme boreal winter and summer wave conditions under future sea-level rise (SLR) and wave climate scenarios were simulated at two atolls, Wake and Midway, using a shallow-water hydrodynamic model. Nearshore wave conditions were used to compute the potential longshore sediment flux along island shorelines via the CERC empirical formula and wave-driven erosion was calculated as the divergence of the longshore drift; run-up and the locations where the run-up exceed the berm elevation were also determined. SLR is projected to predominantly drive future island morphological change and flooding. Seaward shorelines (i.e., ocean fronted shorelines directly facing incident wave energy) were projected to experience greater erosion and flooding with SLR and in hypothetical scenarios where changes to deep water wave directions were altered, as informed by previous climate change forced Pacific wave modeling efforts. These changes caused nearshore waves to become more shore-normal, increasing wave attack along previously protected shorelines. With SLR, leeward shorelines (i.e., an ocean facing shoreline but sheltered from incident wave energy) became more accretive on windward islands and marginally more erosive along leeward islands. These shorelines became more accretionary and subject to more flooding with nearshore waves becoming more shore-normal. Lagoon shorelines demonstrated the greatest SLR-driven increase in erosion and run-up. They exhibited the greatest relative change with increasing wave heights where both erosion and run-up magnitudes increased. Wider

  5. Projected atoll shoreline and run-up changes in response to sea-level rise and varying large wave conditions at Wake and Midway Atolls, Northwestern Hawaiian Islands

    Science.gov (United States)

    Shope, James B.; Storlazzi, Curt D.; Hoeke, Ron K.

    2017-10-01

    Atoll islands are dynamic features that respond to seasonal alterations in wave conditions and sea level. It is unclear how shoreline wave run-up and erosion patterns along these low elevation islands will respond to projected sea-level rise (SLR) and changes in wave climate over the next century, hindering communities' preparation for the future. To elucidate how these processes may respond to climate change, extreme boreal winter and summer wave conditions under future sea-level rise (SLR) and wave climate scenarios were simulated at two atolls, Wake and Midway, using a shallow-water hydrodynamic model. Nearshore wave conditions were used to compute the potential longshore sediment flux along island shorelines via the CERC empirical formula and wave-driven erosion was calculated as the divergence of the longshore drift; run-up and the locations where the run-up exceed the berm elevation were also determined. SLR is projected to predominantly drive future island morphological change and flooding. Seaward shorelines (i.e., ocean fronted shorelines directly facing incident wave energy) were projected to experience greater erosion and flooding with SLR and in hypothetical scenarios where changes to deep water wave directions were altered, as informed by previous climate change forced Pacific wave modeling efforts. These changes caused nearshore waves to become more shore-normal, increasing wave attack along previously protected shorelines. With SLR, leeward shorelines (i.e., an ocean facing shoreline but sheltered from incident wave energy) became more accretive on windward islands and marginally more erosive along leeward islands. These shorelines became more accretionary and subject to more flooding with nearshore waves becoming more shore-normal. Lagoon shorelines demonstrated the greatest SLR-driven increase in erosion and run-up. They exhibited the greatest relative change with increasing wave heights where both erosion and run-up magnitudes increased. Wider

  6. Feasibility study of a novel dew point air conditioning system for China building application

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Xudong; Yang, Shuang; Duan, Zhiyin; Riffat, Saffa B. [School of the Built Environment, University of Nottingham, University Park, Nottingham NG7 2RD (United Kingdom)

    2009-09-15

    The paper investigated the feasibility of a novel dew point evaporative cooling for air conditioning of buildings in China regions. The issues involved include analyses of China weather conditions, investigation of availability of water for dew point cooling, and assessment of cooling capacity of the system within various regions of China. It is concluded that the dew point system is suitable for most regions of China, particularly northern and west regions of China where the climate is hot and dry during the summer season. It is less suitable for Guangzhou and Shanghai where climates are hot and humid. However, an air pre-treatment process involving a silica-gel dehumidification will enable the technology to be used for these humid areas. Lower humidity results in a higher difference between the dry bulb and dew point of the air, which benefits the system in terms of enhancing its cooling performance. Tap water has adequate temperature to feed the system for cooling and its consumption rate is in the range 2.6-3 litres per kWh cooling output. The cooling output of the system ranges from 1.1 to 4.3 W per m{sup 3}/h air flow rate in China, depending on the region where the system applies. For a unit with 2 kW of cooling output, the required air volume flow rate varies with its application location and is in the range 570-1800 m{sup 3}/h. For a 50 m{sup 2} building with 60 W/m{sup 2} cooling load, if the system operates at working hours, i.e., 09:00 to 17:00 h, its daily water consumption would be in the range of 60-70 litres. Compared with mild or humid climates, the dry and hot climates need less air volume flow rate and less water. (author)

  7. Analysis of energy efficiency retrofit schemes for heating, ventilating and air-conditioning systems in existing office buildings based on the modified bin method

    International Nuclear Information System (INIS)

    Wang, Zhaoxia; Ding, Yan; Geng, Geng; Zhu, Neng

    2014-01-01

    Highlights: • A modified bin method is adopted to propose and optimize the EER schemes. • A case study is presented to demonstrate the analysis procedures of EER schemes. • Pertinent EER schemes for HVAC systems are proposed for the object building. - Abstract: Poor thermal performance of building envelop and low efficiencies of heating, ventilating and air-conditioning (HVAC) systems can always be found in the existing office buildings with large energy consumption. This paper adopted a modified bin method to propose and optimize the energy efficiency retrofit (EER) schemes. An existing office building in Tianjin was selected as an example to demonstrate the procedures of formulating the design scheme. Pertinent retrofit schemes for HVAC system were proposed after the retrofit of building envelop. With comprehensive consideration of energy efficiency and economic benefits, the recommended scheme that could improve the overall energy efficiency by 71.20% was determined

  8. The Barriers and Causes of Building Information Modelling Usage for Interior Design Industry

    Science.gov (United States)

    Hamid, A. B. Abd; Taib, M. Z. Mohd; Razak, A. H. N. Abdul; Embi, M. R.

    2017-12-01

    Building Information Modeling (BIM) has since developed alongside the improvement in the construction industry, purposely to simulate the design, management, construction and documentation. It facilitates and monitors the construction through visualization and emphasizes on various inputs to virtually design and construct a building using specific software. This study aims to identify and elaborate barriers of BIM usage in interior design industry in Malaysia. This study is initiated with a pilot survey utilising sixteen respondents that has been randomly chosen. Respondents are attached with interior design firms that are registered by Lembaga Arkitek Malaysia (LAM). The research findings are expected to provide significant information to encourage BIM adoption among interior design firms.

  9. Assessment of respondent acceptability of preference measures: discriminatory power of graphic positioning scale versus traditional scaling measures.

    Science.gov (United States)

    Franic, Duska M; Pathak, Dev S

    2003-01-01

    The objective of this study was to compare discriminatory power of two different measures-graphic positioning scale (GPS) versus traditional scale (TS)-in assessing respondent acceptability of three preference measures: visual analog scale (VAS), standard gamble (SG), and willingness to pay (WTP). Two face-to-face interviews were conducted at least 1 week apart in a convenience sample of women aged 22 to 50 years with no history of breast cancer or cancer requiring chemotherapy. Study participation required completion of two surveys: one evaluating health preferences for an acute condition (chemotherapy-induced nausea and vomiting) and one evaluating a chronic condition (breast cancer). Data were collected from March 2000 to June 2000 at Ohio State University. Respondents were randomized to either GPS or TS surveys. Data analysis was a two-step process. First, a four-way multivariate repeated-measures analysis of variance (MANOVA) was conducted to assess respondent acceptability of three-preference metrics-VAS, SG, and WTP-in health-care decision making. Each of the four dependent variables, difficulty, clarity, reasonableness, and comfort in use in decision making, was measured on 9-point Likert scale. Second, a mixed design univariate analysis of variance (ANOVA) was performed for each dependent variable to optimize MANOVA analysis. Univariate ANOVAs, 2 x (2 x 3), were composed of three independent variables: assessment (GPS/TS), condition (acute and chronic), and preferences (VAS, SG, WTP). Of 126 respondents, 119 were usable and complete. MANOVA results showed (P <.05) for two main effects, condition (F4,114 = 6.375) and preferences (F8,110 = 9.290), and two significant interactions, condition x assessment (F4,114 = 3.421) and condition x preferences (F8,110 = 2.087). GPS has higher discriminatory power than TS in assessing respondent attitudes toward health preference measures. Results showed that respondents had more difficulty and less comfort when making

  10. Mischievous responding in Internet Gaming Disorder research

    Directory of Open Access Journals (Sweden)

    Andrew K. Przybylski

    2016-09-01

    Full Text Available The most recent update to the American Psychiatric Association’s (APA Diagnostic and Statistical Manual of Mental Disorders (DSM-5 included Internet Gaming Disorder as a new potential psychiatric condition that merited further scientific study. The present research was conducted in response to the APA Substance-Related Disorders Working Group’s research call to estimate the extent to which mischievous responding—a known problematic pattern of participant self-report responding in questionnaires—is relevant to Internet Gaming Disorder research. In line with a registered sampling and analysis plan, findings from two studies (ntot = 11,908 provide clear evidence that mischievous responding is positively associated with the number of Internet Gaming Disorder indicators participants report. Results are discussed in the context of ongoing problem gaming research and the discussion provides recommendations for improving the quality of scientific practice in this area.

  11. Building thermography as a tool in energy audits and building commissioning procedure

    Science.gov (United States)

    Kauppinen, Timo

    2007-04-01

    A Building Commissioning-project (ToVa) was launched in Finland in the year 2003. A comprehensive commissioning procedure, including the building process and operation stage was developed in the project. This procedure will confirm the precise documentation of client's goals, definition of planning goals and the performance of the building. It is rather usual, that within 1-2 years after introduction the users complain about the defects or performance malfunctions of the building. Thermography is one important manual tool in verifying the thermal performance of the building envelope. In this paper the results of one pilot building (a school) will be presented. In surveying the condition and energy efficiency of buildings, various auxiliary means are needed. We can compare the consumption data of the target building with other, same type of buildings by benchmarking. Energy audit helps to localize and determine the energy saving potential. The most general and also most effective auxiliary means in monitoring the thermal performance of building envelopes is an infrared camera. In this presentation some examples of the use of thermography in energy audits are presented.

  12. IMCOM LONWORKS Building Automation Systems Implementation Strategy

    National Research Council Canada - National Science Library

    Schwenk, David M; Bush, Joseph; Hughes, Lucie M; Briggs, Stephen; White, Will

    2007-01-01

    Army Installations often expand their use of digital control systems for heating, ventilating, and air conditioning and other mechanical and electrical building systems on a building-by-building basis...

  13. Assessment of monitored energy use and thermal comfort conditions in mosques in hot-humid climates

    Energy Technology Data Exchange (ETDEWEB)

    Al-Homoud, Mohammad S.; Abdou, Adel A.; Budaiwi, Ismail M. [Architectural Engineering Department, KFUPM, Dhahran 31261 (Saudi Arabia)

    2009-06-15

    In harsh climatic regions, buildings require air-conditioning in order to provide an acceptable level of thermal comfort. In many situations buildings are over cooled or the HVAC system is kept running for a much longer time than needed. In some other situations thermal comfort is not achieved due to improper operation practices coupled with poor maintenance and even lack it, and consequently inefficient air-conditioning systems. Mosques represent one type of building that is characterized by their unique intermittent operating schedule determined by prayer times, which vary continuously according to the local solar time. This paper presents the results of a study designed to monitor energy use and thermal comfort conditions of a number of mosques in a hot-humid climate so that both energy efficiency and the quality of thermal comfort conditions especially during occupancy periods in such intermittently operated buildings can be assessed accurately. (author)

  14. Auditable safety analysis for the surveillance and maintenance of the 224-B building

    International Nuclear Information System (INIS)

    Cuneo, V.J.

    1997-02-01

    The Plutonium Concentration Facility (224-B Building) is an inactive, surplus facility that operated from 1945 until 1976. This document provides the auditable safety analysis (ASA) for the post-deactivation, long-term surveillance and maintenance phase of the abovegrade structures of the 224-B Building. In this ASA, the ability of the existing facilities to withstand the effects of natural phenomena hazard events is evaluated and the support systems used to maintain ventilation and/or prevent the spread of contamination are described. The purpose of the S ampersand M phase is as follows: Maintain confinement of residual inventories of radioactive materials and other contaminants until the facility is ultimately dispositioned; Prevent deterioration of confinement structures; Respond to potential accident conditions requiring response and mitigation; Provide for the safety of workers involved in the S ampersand M phase; and Provide the basis for evaluation and selection of ultimate disposal alternatives. In this ASA, the ability of the existing facilities to withstand the effects of natural phenomena hazard (NPH) events is evaluated and the support systems used to maintain ventilation and/or prevent the spread of contamination are described. This document also evaluates S ampersand M activities that are routinely required (i.e., the S ampersand M of facility barriers, equipment, structures, and postings [including repair and upgrade]; measures to identify, remove, or repair damaged asbestos; measures to identify, remove, or appropriately manage existing containers of hazardous substances; nondestructive assay, waste characterization and sampling; and the performance of spill response measures as needed). The type and nature of the hazards presented by the 224-B Building and specific controls that are required to maintain these hazards to acceptable levels are also identified

  15. ASEAN-USAID Buildings Energy Conservation Project. Final report, Volume 3: Audits

    Energy Technology Data Exchange (ETDEWEB)

    Loewen, J.M.; Levine, M.D.; Busch, J.F. [eds.

    1992-06-01

    The auditing subproject of the ASEAN-USAID Buildings Energy Conservation Project has generated a great deal of auditing activity throughout the ASEAN region. Basic building characterisfic and energy consumption data were gathered for over 200 buildings and are presented in this volume. A large number of buildings were given more detailed audits and were modeled with either the ASEAM-2 computer program or the more complex DOE-2 program. These models were used to calculate the savings to be generated by conservabon measures. Specially audits were also conducted, including lighting and thermal comfort surveys. Many researchers in the ASEAN region were trained to perform energy audits in a series of training courses and seminars. The electricity intensifies of various types of ASEAN buildings have been calculated. A comparison to the electricity intensity of the US building stock tentatively concludes that ASEAN office buildings are comparable, first class hotels and retail stores are more ewctricity intensive than their US counterparts, and hospitals are less intensive. Philippine and Singapore lighting surveys indicate that illuminance levels in offices tend to be below the minimum accepted standard. Computer simulations of the energy use in various building types generally agree that for most ASEAN buildings, electricity consumption for air-conditioning (including fan power) consumes approximately 60% of total building electricity. A review of the many studies made during the Project to calculate the savings from energy conservation opportunities (ECOS) shows a median potential savings of approximately 10%, with some buildings saving as much as 50%. Singapore buildings, apparently as a result of previously implemented efficient energy-use practices, shows a lower potential for savings than the other ASEAN nations. Air-conditioning ECOs hold the greatest potential for savings.

  16. The Relational Responding Task: Toward a New Implicit Measure of Beliefs

    Directory of Open Access Journals (Sweden)

    Jan eDe Houwer

    2015-03-01

    Full Text Available We introduce the Relational Responding Task (RRT as a tool for capturing beliefs at the implicit level. Flemish participants were asked to respond as if they believed that Flemish people are more intelligent than immigrants (e.g., respond true to the statement Flemish people are wiser than immigrants or to respond as if they believed that immigrants are more intelligent than Flemish people (e.g., respond true to the statement Flemish people are dumber than immigrants. The difference in performance between these two tasks correlated with ratings of the extent to which participants explicitly endorsed the belief that Flemish people are more intelligent than immigrants and with questionnaire measures of subtle and blatant racism. The current study provides a first step towards validating RRT effects as a viable measure of implicit beliefs.

  17. A Study on the Development of Building Energy Analysis Program and the Establishment of BEPS

    Energy Technology Data Exchange (ETDEWEB)

    Kong, S.R.; Kwon, K.J.; Yoo, Y.H.; Cho, Y.K.; Kijm, Y.D.; Han, S.W. [Korea Electric Power Corp. (KEPCO), Taejon (Korea, Republic of). Research Center; Kim, M.H.; Kim, K.W.; Cho, K.H.; Lee, H.W.; Lee, Y.H.; Kim, S.J.; Song, K.S.; Heon, C.T.; Choi, J.M.; Kim, Y.I.; Suk, H.T.; Kang, J.S.; Kim, Y.D.; Kang, K.T.; Lee, J.E.; Kwark, H.S. [Seoul National Univ. (Korea, Republic of)

    1994-12-31

    The amount of energy consumption in building covers the 30% of the total energy consumption and that of electricity is much the same. Because of the improvement of the living quality, energy consumption in building part is increasing and the rate is much higher than that of other parts. So, KEPCO, one of the major domestic energy suppliers and consumers, needs to develop reliable computerized building energy analysis program and to establish building energy performance standards for the reasonable energy management and the efficient execution of energy budget and the improvement of working condition of the corp`s buildings. So the study aims to the development of computerized building energy analysis program, and the establishment energy budget level and building energy performance standards for the corp`s buildings.

  18. The subsurface hydrology around Building 9201-2: Results of the July 1994 water level recovery test, Oak Ridge Y-12 plant, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1996-06-01

    A water level recovery test was conducted at Building 9201-2 at the Oak Ridge Y-12 Plant in Oak Ridge, Tennessee, from 12:45 p.m. on July 29 until 8:22 a.m. on July 31, 1994. The purpose of the test was to improve the general understanding of the subsurface hydrology around the building. The information is needed to determine the minimum pumping capacity necessary to maintain safe water levels in the basement of the building and to assist in designing systems for treating mercury-bearing waters in the basement. The test was initiated by shutting off the three main sump pumps in Building 9201-2 (i.e., O-12, E-13, and E-22) for 43.5 hr and allowing the water in the basement to approach a static level. The pumps in sumps F-3 and P-6 were also not operating during the test. During the test, water levels were monitored in 5 sumps (P-6, O-12, F-3, E-13, and E-22); a pit near sump K-22; 4 monitoring wells or piezometers in the basement near the O-12 sump, and 16 wells outside of the building. Sump K-22 was dry during the entire test

  19. Quality of courses evaluated by 'predictions' rather than opinions: Fewer respondents needed for similar results.

    Science.gov (United States)

    Cohen-Schotanus, Janke; Schönrock-Adema, Johanna; Schmidt, Henk G

    2010-01-01

    A well-known problem with student surveys is a too low response rate. Experiences with predicting electoral outcomes, which required much smaller sample sizes, inspired us to adopt a similar approach to course evaluation. We expected that having respondents estimate the average opinions of their peers required fewer respondents for comparable outcomes than giving own opinions. Two course evaluation studies were performed among successive first-year medical students (N = 380 and 450, respectively). Study 1: Half the cohort gave opinions on nine questions, while the other half predicted the average outcomes. A prize was offered for the three best predictions (motivational remedy). Study 2: Half the cohort gave opinions, a quarter made predictions without a prize and a quarter made predictions with previous year's results as prior knowledge (cognitive remedy). The numbers of respondents required for stable outcomes were determined following an iterative process. Differences between numbers of respondents required and between average scores were analysed with ANOVA. In both studies, the prediction conditions required significantly fewer respondents (p < 0.001) for comparable outcomes. The informed prediction condition required the fewest respondents (N < 20). Problems with response rates can be reduced by asking respondents to predict evaluation outcomes rather than giving opinions.

  20. Moisture dynamics in building envelopes

    Energy Technology Data Exchange (ETDEWEB)

    Peuhkuri, R.

    2003-07-01

    The overall scope of this Thesis 'Moisture dynamics in building envelopes' has been to characterise how the various porous insulation materials investigated performed hygro thermally under conditions similar to those in a typical building envelope. As a result of the changing temperature and moisture conditions in the exterior weather and indoor climate the materials dynamically absorb and release moisture. The complexity of the impact of these conditions on the resulting moisture transport and content of the materials has been studied in this Thesis with controlled laboratory tests. (au)

  1. Novel Methods to Explore Building Energy Sensitivity to Climate and Heat Waves Using PNNL's BEND Model

    Science.gov (United States)

    Burleyson, C. D.; Voisin, N.; Taylor, T.; Xie, Y.; Kraucunas, I.

    2017-12-01

    The DOE's Pacific Northwest National Laboratory (PNNL) has been developing the Building ENergy Demand (BEND) model to simulate energy usage in residential and commercial buildings responding to changes in weather, climate, population, and building technologies. At its core, BEND is a mechanism to aggregate EnergyPlus simulations of a large number of individual buildings with a diversity of characteristics over large spatial scales. We have completed a series of experiments to explore methods to calibrate the BEND model, measure its ability to capture interannual variability in energy demand due to weather using simulations of two distinct weather years, and understand the sensitivity to the number and location of weather stations used to force the model. The use of weather from "representative cities" reduces computational costs, but often fails to capture spatial heterogeneity that may be important for simulations aimed at understanding how building stocks respond to a changing climate (Fig. 1). We quantify the potential reduction in temperature and load biases from using an increasing number of weather stations across the western U.S., ranging from 8 to roughly 150. Using 8 stations results in an average absolute summertime temperature bias of 4.0°C. The mean absolute bias drops to 1.5°C using all available stations. Temperature biases of this magnitude translate to absolute summertime mean simulated load biases as high as 13.8%. Additionally, using only 8 representative weather stations can lead to a 20-40% bias of peak building loads under heat wave or cold snap conditions, a significant error for capacity expansion planners who may rely on these types of simulations. This analysis suggests that using 4 stations per climate zone may be sufficient for most purposes. Our novel approach, which requires no new EnergyPlus simulations, could be useful to other researchers designing or calibrating aggregate building model simulations - particularly those looking at

  2. Building air quality: A guide for building owners and facility managers

    International Nuclear Information System (INIS)

    1991-12-01

    The guide was intended to help those individuals responsible for air quality control in buildings to prevent indoor air quality problems from developing and resolving such problems quickly should they develop. Background information and guidance on dealing with indoor air quality problems were provided. Specific topics included: factors which affect indoor air quality; sources of indoor air contaminants; heating, ventilation and air conditioning (HVAC) systems; the role of building occupants; effective communication between managers and others involved; developing an indoor air quality (IAQ) profile; managing a building for good IAQ; diagnosing IAQ problems; mitigating IAQ problems, hiring professional assistance to solve an IAQ problem; common IAQ measurements; HVAC systems and IAQ; moisture with resultant mold and mildew conditions; asbestos (1332214); radon (10043922); and resources through which additional information can be obtained. Indoor air quality forms were included which can be modified to meet individual needs

  3. Aging characteristics of containment building and sensitivity on ultimate pressure capacity

    International Nuclear Information System (INIS)

    Seo, Jeong Moon; Choun, Young Sun; Choi, In Kil; Ha, Jae Joo

    1998-03-01

    For the reliable safety assessment of the containment building, structural and material conditions can be investigated in detail and pertinent assessment technologies have to be established. Also, an understanding on the aging-related degradations for the construction materials is required to predict long-term structural safety of the containment building. For the development of reliable aging prediction models, an extensive data base system related to aging properties of the containment building has to be prepared. The objectives of this research are to develop aging models representing long-term degradation of materials and a structural performance assessment program for containment building considering aging-related degradation. According to the results of sensitivity analysis, as the mechanical properties of the constituent materials degrade, the ultimate pressure capacity of containment building may decrease and severe damage may occur around the mid-level of the containment wall. (author). 28 refs., 11 tabs., 36 figs

  4. 49 CFR 622.301 - Buildings.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false Buildings. 622.301 Section 622.301 Transportation... Buildings. (a) FTA assistance for the construction, reconstruction, or modification of buildings for which... a building, within the scope of the proposed construction activity and at a level of detail...

  5. Preconditioning in the reef-building coral Pocillopora damicornis and the potential for trans-generational acclimatization in coral larvae under future climate change conditions.

    Science.gov (United States)

    Putnam, Hollie M; Gates, Ruth D

    2015-08-01

    Coral reefs are globally threatened by climate change-related ocean warming and ocean acidification (OA). To date, slow-response mechanisms such as genetic adaptation have been considered the major determinant of coral reef persistence, with little consideration of rapid-response acclimatization mechanisms. These rapid mechanisms such as parental effects that can contribute to trans-generational acclimatization (e.g. epigenetics) have, however, been identified as important contributors to offspring response in other systems. We present the first evidence of parental effects in a cross-generational exposure to temperature and OA in reef-building corals. Here, we exposed adults to high (28.9°C, 805 µatm P(CO2)) or ambient (26.5°C, 417 µatm P(CO2)) temperature and OA treatments during the larval brooding period. Exposure to high treatment negatively affected adult performance, but their larvae exhibited size differences and metabolic acclimation when subsequently re-exposed, unlike larvae from parents exposed to ambient conditions. Understanding the innate capacity corals possess to respond to current and future climatic conditions is essential to reef protection and maintenance. Our results identify that parental effects may have an important role through (1) ameliorating the effects of stress through preconditioning and adaptive plasticity, and/or (2) amplifying the negative parental response through latent effects on future life stages. Whether the consequences of parental effects and the potential for trans-generational acclimatization are beneficial or maladaptive, our work identifies a critical need to expand currently proposed climate change outcomes for corals to further assess rapid response mechanisms that include non-genetic inheritance through parental contributions and classical epigenetic mechanisms. © 2015. Published by The Company of Biologists Ltd.

  6. Design Buildings Optimally: A Lifecycle Assessment Approach

    KAUST Repository

    Hosny, Ossama

    2013-01-01

    This paper structures a generic framework to support optimum design for multi-buildings in desert environment. The framework is targeting an environmental friendly design with minimum lifecycle cost, using Genetic Algorithms (Gas). GAs function through a set of success measures which evaluates the design, formulates a proper objective, and reflects possible tangible/intangible constraints. The framework optimizes the design and categorizes it under a certain environmental category at minimum Life Cycle Cost (LCC). It consists of three main modules: (1) a custom Building InformationModel (BIM) for desert buildings with a compatibility checker as a central interactive database; (2) a system evaluator module to evaluate the proposed success measures for the design; and (3) a GAs optimization module to ensure optimum design. The framework functions through three levels: the building components, integrated building, and multi-building levels. At the component level the design team should be able to select components in a designed sequence to ensure compatibility among various components, while at the building level; the team can relatively locate and orient each individual building. Finally, at the multi-building (compound) level the whole design can be evaluated using success measures of natural light, site capacity, shading impact on natural lighting, thermal change, visual access and energy saving. The framework through genetic algorithms optimizes the design by determining proper types of building components and relative buildings locations and orientations which ensure categorizing the design under a specific category or meet certain preferences at minimum lifecycle cost.

  7. Capacity building toward evidence-based medicine among healthcare professionals at the university of medicine and pharmacy, ho chi minh city, and its related institutes.

    Science.gov (United States)

    Nga, LE Thi Quynh; Goto, Aya; Trung, Tran The; Vinh, Nguyen Quang; Khue, Nguyen Thy

    2014-02-01

    Research capacity development enhances a country's ownership of activities aimed at strengthening its health system. In Vietnam, continuing medical education (CME) is attracting increasing attention with the establishment of legal and policy frameworks. During 2010-2013, the Japan International Cooperation Agency funded a research capacity building project targeting physicians in Ho Chi Minh City. The project had been developed in four previous courses that were conducted in collaboration with Fukushima Medical University and Ho Chi Minh City University of Medicine and Pharmacy (UMP). The project succeeded in obtaining accreditation as the city's CME course. A total of 262 physicians attended three courses that have a divided set of research competencies. Following the Kirkpatrick Model for evaluating the effectiveness of training programs, we confirmed the participants' positive reaction to the courses (Level 1 evaluation), their perceived increase in knowledge and confidence in research skills (Level 2 evaluation), and application of learned knowledge in their practice (Level 3 evaluation). Presented here is a step-by-step scaling-up model of health research capacity building. Strategies for the further expansion include: further capacity building of instructors; responding to clinicians' specific needs; building a recruiting system with authorization; and improving the Level 3 training evaluation.

  8. Regional approach to building operational level capacity for disaster planning: the case of the Eastern Africa region.

    Science.gov (United States)

    Bazeyo, W; Mayega, R W; Orach, G C; Kiguli, J; Mamuya, S; Tabu, J S; Sena, L; Rugigana, E; Mapatano, M; Lewy, D; Mock, N; Burnham, G; Keim, M; Killewo, J

    2013-06-01

    The Eastern Africa region is regularly affected by a variety of disasters ranging from drought, to human conflict and population displacement. The magnitude of emergencies and response capacities is similar across the region. In order to strengthen public health disaster management capacities at the operational level in six countries of the Eastern Africa region, the USAID-funded leadership project worked through the HEALTH Alliance, a network of seven schools of public health from six countries in the region to train district-level teams. To develop a sustainable regional approach to building operational level capacity for disaster planning. This project was implemented through a higher education leadership initiative. Project activities were spear-headed by a network of Deans and Directors of public health schools within local universities in the Eastern Africa region. The leadership team envisioned a district-oriented systems change strategy. Pre-service and in-service curricula were developed regionally and district teams were formed to attend short training courses. Project activities began with a situational analysis of the disaster management capacity at national and operational levels. The next steps were chronologically the formation of country training teams and training of trainers, the development of a regional disaster management training curriculum and training materials, the cascading of training activities in the region, and the incorporation of emerging issues into the training curriculum. An evaluation model included the analysis of preparedness impact of the training program. The output from the district teams was the creation of individual district-level disaster plans and their implementation. This 4-year project focused on building operational level public health emergency response capacity, which had not previously been part of any national program. Use of the all-hazard approach rather than a scenario-based contingency planning led to the

  9. Effect of nonlinearity of connecting dampers on vibration control of connected building structures

    Directory of Open Access Journals (Sweden)

    Masatoshi eKasagi

    2016-01-01

    Full Text Available The connection of two building structures with dampers is one of effective vibration control systems. In this vibration control system, both buildings have to possess different vibration properties in order to provide a higher vibration reduction performance. In addition to such condition of different vibration properties of both buildings, the connecting dampers also play an important role in the vibration control mechanism. In this paper, the effect of nonlinearity of connecting dampers on the vibration control of connected building structures is investigated in detail. A high-damping rubber damper and an oil damper with and without relief mechanism are treated. It is shown that, while the high-damping rubber damper is effective in a rather small deformation level, the linear oil damper is effective in a relatively large deformation level. It is further shown that, while the oil dampers reduce the response in the same phase as the case without dampers, the high-damping rubber dampers change the phase. The merit is that the high-damping rubber can reduce the damper deformation and keep the sufficient space between both buildings. This can mitigate the risk of building pounding.

  10. Empirical Tryout of a New Statistic for Detecting Temporally Inconsistent Responders.

    Science.gov (United States)

    Kerry, Matthew J

    2018-01-01

    Statistical screening of self-report data is often advised to support the quality of analyzed responses - For example, reduction of insufficient effort responding (IER). One recently introduced index based on Mahalanobis's D for detecting outliers in cross-sectional designs replaces centered scores with difference scores between repeated-measure items: Termed person temporal consistency ( D 2 ptc ). Although the adapted D 2 ptc index demonstrated usefulness in simulation datasets, it has not been applied to empirical data. The current study addresses D 2 ptc 's low uptake by critically appraising its performance across three empirical applications. Independent samples were selected to represent a range of scenarios commonly encountered by organizational researchers. First, in Sample 1, a repeat-measure of future time perspective (FTP) inexperienced working adults (age >40-years; n = 620) indicated that temporal inconsistency was significantly related to respondent age and item reverse-scoring. Second, in repeat-measure of team efficacy aggregations, D 2 ptc successfully detected team-level inconsistency across repeat-performance cycles. Thirdly, the usefulness of the D 2 ptc was examined in an experimental study dataset of subjective life expectancy indicated significantly more stable responding in experimental conditions compared to controls. The empirical findings support D 2 ptc 's flexible and useful application to distinct study designs. Discussion centers on current limitations and further extensions that may be of value to psychologists screening self-report data for strengthening response quality and meaningfulness of inferences from repeated-measures self-reports. Taken together, the findings support the usefulness of the newly devised statistic for detecting IER and other extreme response patterns.

  11. MEMS CHIP CO2 SENSOR FOR BUILDING SYSTEMS INTEGRATION

    Energy Technology Data Exchange (ETDEWEB)

    Anton Carl Greenwald

    2005-09-14

    The objective of this research was to develop an affordable, reliable sensor to enable demand controlled ventilation (DCV). A significant portion of total energy consumption in the United States is used for heating or air conditioning (HVAC) buildings. To assure occupant safety and fresh air levels in large buildings, and especially those with sealed windows, HVAC systems are frequently run in excess of true requirements as automated systems cannot now tell the occupancy level of interior spaces. If such a sensor (e.g. thermostat sized device) were available, it would reduce energy use between 10 and 20% in such buildings. A quantitative measure of ''fresh air'' is the concentration of carbon dioxide (CO{sub 2}) present. An inert gas, CO{sub 2} is not easily detected by chemical sensors and is usually measured by infrared spectroscopy. Ion Optics research developed a complete infrared sensor package on a single MEMS chip. It contains the infrared (IR) source, IR detector and IR filter. The device resulting from this DOE sponsored research has sufficient sensitivity, lifetime, and drift rate to meet the specifications of commercial instrument manufacturers who are now testing the device for use in their building systems.

  12. ADAPTIVE BUILDING EXOSKELETONS: A biomimetic model for the rehabilitation of social housing

    Directory of Open Access Journals (Sweden)

    Giuliana Scuderi

    2015-03-01

    Full Text Available This research is an attempt to describe a new biomimetic model for the rehabilitation of social housing. In particular, the constructions built in Europe in the post Second World War period suffer of material and social degradation requiring architectural, functional and structural interventions. The analysis of the state of the art underlined the importance of the envelope in the definition of new performances and standards. Through a bio-mimicry approach, the paper shows the process leading to the definition of a building exoskeleton: a structural envelope able to solve complex sets of problems integrating different building systems. Adaptability results being a fundamental property to define an effective seismic and structural behavior but also to respond to changing user’s needs and environmental conditions. In the last part of the paper, information about feasible technologies and techniques to realize the exoskeleton are presented. Finally, the conclusions show the potentiality of the model if applied in critical contexts where intensive and diffusive interventions of recovery of social housing are needed.

  13. Performance Evaluation of Three-Level Z-Source Inverters Under Semiconductor-Failure Conditions

    DEFF Research Database (Denmark)

    Gao, Feng; Loh, Poh Chiang; Blaabjerg, Frede

    2009-01-01

    This paper evaluates and proposes various compensation methods for three-level Z-source inverters under semiconductor-failure conditions. Unlike the fault-tolerant techniques used in traditional three-level inverters, where either an extra phase-leg or collective switching states are used......, the proposed methods for three-level Z-source inverters simply reconfigure their relevant gating signals so as to ride-through the failed semiconductor conditions smoothly without any significant decrease in their ac-output quality and amplitude. These features are partly attributed to the inherent boost...... under semiconductor-failure conditions. For verifying these described performance features, PLECS simulation and experimental testing were performed with some results captured and shown in a later section for visual confirmation....

  14. Curcumin elevates sirtuin level but does not postpone in vitro senescence of human cells building the vasculature

    Science.gov (United States)

    Grabowska, Wioleta; Suszek, Małgorzata; Wnuk, Maciej; Lewinska, Anna; Wasiak, Emilia; Sikora, Ewa; Bielak-Zmijewska, Anna

    2016-01-01

    It is believed that curcumin, a component of the turmeric that belongs to hormetins, possesses anti-aging propensity. This property of curcumin can be partially explained by its influence on the level of sirtuins. Previously, we have shown that relatively high (2.5-10 μM) doses of curcumin induce senescence of cancer cells and cells building the vasculature. In the present study we examined whether curcumin at low doses (0.1 and 1 μM) is able to delay cell senescence and upregulate the level of sirtuins in human cells building the vasculature, namely vascular smooth muscle (VSMC) and endothelial (EC) cells. To this end we used cells senescing in a replicative and premature manner. We showed that low doses of curcumin in case of VSMC neither postponed the replicative senescence nor protected from premature senescence induced by doxorubicin. Moreover, curcumin slightly accelerated replicative senescence of EC. Despite some fluctuations, a clear increasing tendency in the level of sirtuins was observed in curcumin-treated young, senescing or already senescent cells. Sirtuin activation could be caused by the activation of AMPK resulting from superoxide elevation and ATP reduction. Our results show that curcumin at low doses can increase the level of sirtuins without delaying senescence of VSMC. PMID:27034011

  15. Earthquake risk assessment of building structures

    International Nuclear Information System (INIS)

    Ellingwood, Bruce R.

    2001-01-01

    During the past two decades, probabilistic risk analysis tools have been applied to assess the performance of new and existing building structural systems. Structural design and evaluation of buildings and other facilities with regard to their ability to withstand the effects of earthquakes requires special considerations that are not normally a part of such evaluations for other occupancy, service and environmental loads. This paper reviews some of these special considerations, specifically as they pertain to probability-based codified design and reliability-based condition assessment of existing buildings. Difficulties experienced in implementing probability-based limit states design criteria for earthquake are summarized. Comparisons of predicted and observed building damage highlight the limitations of using current deterministic approaches for post-earthquake building condition assessment. The importance of inherent randomness and modeling uncertainty in forecasting building performance is examined through a building fragility assessment of a steel frame with welded connections that was damaged during the Northridge Earthquake of 1994. The prospects for future improvements in earthquake-resistant design procedures based on a more rational probability-based treatment of uncertainty are examined

  16. The influence of indirect collective trauma on first responders' alcohol use.

    Science.gov (United States)

    Homish, Gregory G; Frazer, Bonita S; Carey, Mary G

    2012-01-01

    Previous research has suggested increased risk for negative outcomes such as increased alcohol use among first responders who are involved with the response to a community disaster; however it is not clear how indirect exposure to a critical incident impacts first responders. This work examined the impact of secondary or indirect trauma on changes in alcohol use among urban firefighters who were not directly involved in the response to a large scale community-level disaster. Firefighters enrolled in larger trial of health outcomes whose interview period coincided with the crash of a commercial airplane were the basis for the current report. Aggregate level data on changes in alcohol consumption for these firefighters were examined pre- and post-incident. There was a significant increase in alcohol use following the critical incident. This increase did not occur immediately; it was observed within several days and peaked about 8 days post-incident. Post-hoc analyses revealed that the increased alcohol consumption persisted for several months, finally returning to pre-incident levels by 8 months post-incident. Indirect trauma effects, likely operationalized in part through the "brotherhood" of the firefighters, clearly placed firefighters at risk for negative outcomes following a disaster. Intervention/prevention efforts aimed at distress reduction among first responders should not solely focus on responders with direct involvement in a disaster.

  17. Level III baseline risk evaluation for Building 3505 at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    Mostella, W.B. Jr.

    1994-12-01

    The Level III Baseline Risk Evaluation (BRE) for Building 3505, the ORNL Metal Recovery Facility, provides an analysis of the potential for adverse health effects, current or future, associated with the presence of hazardous substances in the building. The Metal Recovery Facility was used from 1952 through 1960 to process large quantities of radioactive material using the PUREX process for the recovery of uranium-238, plutonium-239, neptunium-237, and americium-241. The facility consists of seven process cells (A through G), a canal, a dissolver room, a dissolver pit, an office, locker room, storage area, control room, electrical gallery, shop, and makeup area. The cells were used to house the nuclear fuel reprocessing equipment, and the canal was constructed to be used as a water-shielded transfer canal. Currently, there are no known releases of radioactive contaminants from Building 3505. To perform the BRE, historical radiological survey data were used to estimate the concentration of alpha- and beta/gamma emitting radionuclides in the various cells, rooms, and other areas in Building 3505. Data from smear surveys were used to estimate the amount of transferable contamination (to which receptors can be exposed via inhalation and ingestion), and data from probe surveys were used to estimate the amount of both fixed and transferable contamination (from which receptors can receive external exposure). Two land use scenarios, current and future, and their subsequent exposure scenarios were explored in the BRE. Under the current land use scenario, two exposure scenarios were evaluated. The first was a worst-case industrial exposure scenario in which the receptor is a maintenance worker who works 8 hours/day, 350 days/year in the building for 25 years. In the second, more realistic exposure scenario, the receptor is a surveillance and maintenance (S ampersand M) worker who spends two 8-hour days/year in the building for 25 years

  18. Appraisal of systematic training practices by building construction ...

    African Journals Online (AJOL)

    It was observed that 89.65% and 91.38% of the respondents agree that management and technical staff training is only embarked on when needed: that ITF ... of building construction workers serves a means of maintaining standards and ensuring that those who are newly engaged into existing jobs and practices are able ...

  19. Indoor Environmental Risk Factors for Occupant Symptoms in 100U.S. Office Buildings: Summary of Three Analyses from the EPA BASEStudy

    Energy Technology Data Exchange (ETDEWEB)

    Mendell, M.J.; Lei-Gomez, Q.; Cozen, M.; Brightman, H.S.; Apte,M.; Erdmann, C.A.; Brunner, G.; Girman, J.R.

    2006-02-01

    This paper summarizes three analyses of data on building-related environmental factors and occupant symptoms collected from 100 representative large U.S. office buildings. Using multivariate logistic regression models, we found increased occupant symptoms associated with a number of building-related factors, including lower ventilation rates even at the current guideline levels, lack of scheduled cleaning for air-conditioning drain pans and cooling coils, poor condition of cooling coils, poorly maintained humidification systems, and lower outdoor air intake height. Some expected relationships were not found, and several findings were opposite of expected. Although requiring replication, these findings suggest preventive actions to reduce occupant symptoms in office buildings.

  20. PLACE-BASED GREEN BUILDING: INTEGRATING LOCAL ENVIRONMENTAL AND PLANNING ANALYSIS INTO GREEN BUILDING GUIDELINES

    Science.gov (United States)

    This project will develop a model for place-based green building guidelines based on an analysis of local environmental, social, and land use conditions. The ultimate goal of this project is to develop a methodology and model for placing green buildings within their local cont...

  1. Foundation heat transfer analysis for buildings with thermal piles

    International Nuclear Information System (INIS)

    Almanza Huerta, Luis Enrique; Krarti, Moncef

    2015-01-01

    Highlights: • A numerical transient thermal model for thermo-active foundations is developed. • Thermal interactions between thermal piles and building foundations are evaluated. • A simplified analysis method of thermal interactions between thermal piles and building foundations is developed. - Abstract: Thermal piles or thermo-active foundations utilize heat exchangers embedded within foundation footings to heat and/or cool buildings. In this paper, the impact of thermal piles on building foundation heat transfer is investigated. In particular, a simplified analysis method is developed to estimate the annual ground-coupled foundation heat transfer when buildings are equipped with thermal piles. First, a numerical analysis of the thermal performance of thermo-active building foundations is developed and used to assess the interactions between thermal piles and slab-on-grade building foundations. The impact of various design parameters and operating conditions is evaluated including foundation pile depth, building slab width, foundation insulation configuration, and soil thermal properties. Based on the results of a series of parametric analyses, a simplified analysis method is presented to assess the impact of the thermal piles on the annual heat fluxes toward or from the building foundations. A comparative evaluation of the predictions of the simplified analysis method and those obtained from the detailed numerical analysis indicated good agreement with prediction accuracy lower than 5%. Moreover, it is found that thermal piles can affect annual building foundation heat loss/gain by up to 30% depending on foundation size and insulation level

  2. Low-Cost Bio-Based Phase Change Materials as an Energy Storage Medium in Building Envelopes

    Energy Technology Data Exchange (ETDEWEB)

    Biswas, Kaushik [ORNL; Abhari, Mr. Ramin [Renewable Energy Group, Inc.; Shukla, Dr. Nitin [Fraunhofer USA, Center for Sustainable Energy Systems (CSE), Boston; Kosny, Dr. Jan [Fraunhofer USA, Center for Sustainable Energy Systems (CSE), Boston

    2015-01-01

    A promising approach to increasing the energy efficiency of buildings is the implementation of phase change material (PCM) in building envelope systems. Several studies have reported the energy saving potential of PCM in building envelopes. However, wide application of PCMs in building applications has been inhibited, in part, by their high cost. This article describes a novel paraffin product made of naturally occurring fatty acids/glycerides trapped into high density polyethylene (HDPE) pellets and its performance in a building envelope application, with the ultimate goal of commercializing a low-cost PCM platform. The low-cost PCM pellets were mixed with cellulose insulation, installed in external walls and field-tested under natural weatherization conditions for a period of several months. In addition, several PCM samples and PCM-cellulose samples were prepared under controlled conditions for laboratory-scale testing. The laboratory tests were performed to determine the phase change properties of PCM-enhanced cellulose insulation both at microscopic and macroscopic levels. This article presents the data and analysis from the exterior test wall and the laboratory-scale test data. PCM behavior is influenced by the weather and interior conditions, PCM phase change temperature and PCM distribution within the wall cavity, among other factors. Under optimal conditions, the field data showed up to 20% reduction in weekly heat transfer through an external wall due to the PCM compared to cellulose-only insulation.

  3. A Laboratory for studying radon mitigation methods in high-rise office buildings in Hong Kong

    International Nuclear Information System (INIS)

    Leung, J.K.C.; Hung, L.C.; Tso, M.Y.W.

    1996-01-01

    A territory-wide survey of indoor radon level in 1993 showed that 17% of offices Hong Kong have radon concentrations above 200 Bq m -3 compared with 4% for dwellings. Consequently, the Radioisotope Unit Radon Analysis Laboratory (RURAL) is being built for studying radon mitigation methods applicable to high-rise office buildings. The laboratory consists of three rooms; the main exposure room is built of concrete and is surrounded by the buffer room; and all controls and operations are done inside the control room. The exposure room can, with the aid of the buffer room, simulate any environmental conditions that can be faced by a real building. The pressure, temperature and humidity can be adjusted to any meteorological conditions that can be found in Hong Kong. Pressure differential and temperature differential can be adjusted to simulate the arrival of fronts, troughs or typhoons. Aerosol concentration and distribution inside the exposure room are controllable as well as the ventilation conditions. Various mitigation methods will be tested under different conditions. Passive methods include application of radon barriers to building structures and active methods include the use of air cleaners; techniques to increase radon daughters plateout or reduce their attachment to aerosols; and various modifications to the ventilation systems. Mitigation techniques involving modifications to the building strictures and building services will also be developed with the help of the RURAL. (author)

  4. 133-144 Radiation Levels in Buildings on the Main Campus of ...

    African Journals Online (AJOL)

    SGSLIB034

    Though differences were observed among buildings of the three different ... Ionizing radiation is one of the potential risks human ... health problems (EC, 1999; Aamidalddin et al., 2015). Radiation exposure due to building materials can be ... which the predominant ones are cement, metal frames ... the construction industry.

  5. Financing a new low-level radioactive waste disposal site

    International Nuclear Information System (INIS)

    Dressen, A.L.; Serie, P.J.; McGarvey, R.S.; Lemmon, R.A.

    1982-01-01

    No new commercial low-level radioactive waste disposal site has been licensed in the past decade. During the time, inflation has wreaked havoc on the costs for the labor, equipment, and buildings that will be necessary to develop and operate new sites. The regulatory environment has become much more complex with enactment of the National Environmental Policy Act (NEPA) and the recent issuance by the Nuclear Regulatory Commission (NRC) of a draft set of comprehensive regulations for land disposal of low-level waste (10 CFR Part 61). Finally, the licensing process itself has become much lengthier as both the site developers and regulators respond to the public's desire to be more involved in decisions that may affect their lives

  6. Responding to the Challenge of True Uncertainty

    DEFF Research Database (Denmark)

    Hallin, Carina Antonia; Andersen, Torben Juul

    We construe a conceptual framework for responding effectively to true uncertainty in the business environment. We drill down to the essential micro-foundational capabilities - sensing and seizing of dynamic capabilities - and link them to classical strategic issue management theory with suggestions...... on how to operationalize these essential capabilities. By definition true uncertainty represents environmental conditions that are hard to foresee, which can catch the unprepared by surprise while presenting opportunities to the conscious organization. We demonstrate that organizations relying...

  7. Conditioning of low- and intermediate-level radioactive wastes

    International Nuclear Information System (INIS)

    1983-01-01

    The nuclear fuel cycle, together with the use of separated radioisotopes, in many endeavours generates a variety of low- and intermediate-level radioactive wastes. These waste materials contain quantities of radionuclides sufficient to present potential health risks to people if the wastes are not adequately managed, but usually insufficient quantities to require heat removal. Adequate management involves a series of steps which lead from the arising of the wastes to their safe disposal, steps which may include collection, segregation, treatment, volume reduction, conditioning, transport, interim storage and disposal. Each step is defined by the need to accommodate to the preceding one and to facilitate the ones that follow. This technical report describes primarily the technologies available for the conditioning steps (i.e., immobilization and packaging) and relates them to the other steps. In broad terms, the purpose of conditioning is to convert the wastes into packages that are suitable for transport, storage and disposal

  8. Low air exchange rate causes high indoor radon concentration in energy-efficient buildings.

    Science.gov (United States)

    Vasilyev, A V; Yarmoshenko, I V; Zhukovsky, M V

    2015-06-01

    Since 1995, requirements on energy-efficient building construction were established in Russian Building Codes. In the course of time, utilisation of such technologies became prevailing, especially in multi-storey building construction. According to the results of radon survey in buildings constructed meeting new requirements on energy efficiency, radon concentration exceeds the average level in early-constructed buildings. Preponderance of the diffusion mechanism of radon entry in modern multi-storey buildings has been experimentally established. The experimental technique of the assessment of ventilation rate in dwellings under real conditions was developed. Based on estimates of average ventilation rate, it was approved that measures to increase energy efficiency lead to reduction in ventilation rate and accumulation of higher radon concentrations indoors. Obtained ventilation rate values have to be considered as extremely low. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  9. Multi-criteria decision making under uncertainty in building performance assessment

    NARCIS (Netherlands)

    Hopfe, C.J.; Augenbroe, G.; Hensen, J.L.M.

    2013-01-01

    Building performance assessment is complex, as it has to respond to multiple criteria. Objectives originating from the demands that are put on energy consumption, acoustical performance, thermal occupant comfort, indoor air quality and many other issues must all be reconciled. An assessment requires

  10. FACTOR ANALYSIS OF MULTISTOREY RESIDENTIAL BUILDINGS ZONE

    Directory of Open Access Journals (Sweden)

    Петр Матвеевич Мазуркин

    2016-02-01

    Full Text Available According to the UN classification of 11 classes of soil cover, the first three are grass, trees and shrubs and forests. In the city they correspond to the three elements of vegetation: lawns, tree plantings (trees and shrubs. We have adopted zoning for city-building to identify statistical regularities. Map dimensions in GIS "Map 2011" Yoshkar-Ola was allocated to "residential zone" and "Area of construction of multi-storey residential buildings (cadastral 58 quart crystals". The parameters of the elements of the vegetation cover have been considered: the number of elements of different levels, area and perimeter, the absolute and relative form, and activity of vegetation. As the result, we have obtained equations of binomial rank distributions, conducted the ratings and selected the best of cadastral quarter on environmental conditions.

  11. Green Building Research Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Sailor, David Jean [Portland State Univ., Portland, OR (United States)

    2013-12-29

    This project provided support to the Green Building Research Laboratory at Portland State University (PSU) so it could work with researchers and industry to solve technical problems for the benefit of the green building industry. It also helped to facilitate the development of PSU’s undergraduate and graduate-level training in building science across the curriculum.

  12. Data and analytics to inform energy retrofit of high performance buildings

    International Nuclear Information System (INIS)

    Hong, Tianzhen; Yang, Le; Hill, David; Feng, Wei

    2014-01-01

    Highlights: • High performance buildings can be retrofitted using measured data and analytics. • Data of energy use, systems operating and environmental conditions are needed. • An energy data model based on the ISO Standard 12655 is key for energy benchmarking. • Three types of analytics are used: energy profiling, benchmarking, and diagnostics. • The case study shows 20% of electricity can be saved by retrofit. - Abstract: Buildings consume more than one-third of the world’s primary energy. Reducing energy use in buildings with energy efficient technologies is feasible and also driven by energy policies such as energy benchmarking, disclosure, rating, and labeling in both the developed and developing countries. Current energy retrofits focus on the existing building stocks, especially older buildings, but the growing number of new high performance buildings built around the world raises a question that how these buildings perform and whether there are retrofit opportunities to further reduce their energy use. This is a new and unique problem for the building industry. Traditional energy audit or analysis methods are inadequate to look deep into the energy use of the high performance buildings. This study aims to tackle this problem with a new holistic approach powered by building performance data and analytics. First, three types of measured data are introduced, including the time series energy use, building systems operating conditions, and indoor and outdoor environmental parameters. An energy data model based on the ISO Standard 12655 is used to represent the energy use in buildings in a three-level hierarchy. Secondly, a suite of analytics were proposed to analyze energy use and to identify retrofit measures for high performance buildings. The data-driven analytics are based on monitored data at short time intervals, and cover three levels of analysis – energy profiling, benchmarking and diagnostics. Thirdly, the analytics were applied to a high

  13. Determination of levels of polychlorinated biphenyls (PCBs) present in caulk and window glazing material samples from older buildings

    Science.gov (United States)

    Levels of polychlorinated biphenyls (PCBs) in caulk and window glazing material samples from older buildings were determined, using a method developed for this purpose. This method was evaluated by analyzing a combination of 47 samples of caulk, glazing materials, including quali...

  14. Method for including detailed evaluation of daylight levels in Be06

    DEFF Research Database (Denmark)

    Petersen, Steffen

    2008-01-01

    Good daylight conditions in office buildings have become an important issue due to new European regulatory demands which include energy consumption for electrical lighting in the building energy frame. Good daylight conditions in offices are thus in increased focus as an energy conserving measure....... In order to evaluate whether a certain design is good daylight design or not building designers must perform detailed evaluation of daylight levels, including the daylight performance of dynamic solar shadings, and include these in the energy performance evaluation. However, the mandatory national...... calculation tool in Denmark (Be06) for evaluating the energy performance of buildings is currently using a simple representation of available daylight in a room and simple assumptions regarding the control of shading devices. In a case example, this is leading to an overestimation of the energy consumption...

  15. Relevance feature selection of modal frequency-ambient condition pattern recognition in structural health assessment for reinforced concrete buildings

    Directory of Open Access Journals (Sweden)

    He-Qing Mu

    2016-08-01

    Full Text Available Modal frequency is an important indicator for structural health assessment. Previous studies have shown that this indicator is substantially affected by the fluctuation of ambient conditions, such as temperature and humidity. Therefore, recognizing the pattern between modal frequency and ambient conditions is necessary for reliable long-term structural health assessment. In this article, a novel machine-learning algorithm is proposed to automatically select relevance features in modal frequency-ambient condition pattern recognition based on structural dynamic response and ambient condition measurement. In contrast to the traditional feature selection approaches by examining a large number of combinations of extracted features, the proposed algorithm conducts continuous relevance feature selection by introducing a sophisticated hyperparameterization on the weight parameter vector controlling the relevancy of different features in the prediction model. The proposed algorithm is then utilized for structural health assessment for a reinforced concrete building based on 1-year daily measurements. It turns out that the optimal model class including the relevance features for each vibrational mode is capable to capture the pattern between the corresponding modal frequency and the ambient conditions.

  16. Energy efficient of the residential buildings based climatic condition using experimental design: a case study in malaysia

    Directory of Open Access Journals (Sweden)

    Zahraee Seyed Mojib

    2017-01-01

    Full Text Available In recent years, energy consumption has become a critical issue in the developed and developing countries. Residential buildings are one of the most users of energy in the construction sector that use the highest share of energy. This paper aims at evaluating the effect of four factors that are temperature, humidity, airflow and pressure on the cooling load in the residential buildings. To achieve this goal, statistical experimental design is used to determine the optimum setting of factors that result in optimum energy usage. Simulation software and energy analysis is used to simulate a two-storey building in Malaysia as the case of study. Final results showed that the temperature, humidity and interaction between them have the most significant effect on the energy cooling load. Moreover, to obtain the minimum value of cooling load the temperature and humidity should be equal to A=20 Celsius degree and B=60% respectively. In addition, the other two insignificant factors, airflow and pressure should be placed at the high level which are equal to C=3 cubic meters per hour, and D=6 Pascal (P respectively.

  17. Ventilated air cavities for the control of rising damp in historical buildings. Functional analysis

    Directory of Open Access Journals (Sweden)

    Mª T. Gil Muñoz

    2018-01-01

    Full Text Available This study analyzes the behavior of ventilated air cavities and their level of efficiency when used for the control of rising damp and the associated pathological damage in walls and foundations of historical buildings. The methodology is based on experiments on-site and monitoring. Knowledge of local climate conditions, the surroundings of the building, its construction features and the type of foundation constitute the preliminary conditions for the monitoring. In order to reach the goal we have measured several parameters according to a plan, developed graphical tools for the study, and prepared statistical data. The building of this system has not always been accompanied by a thorough assessment that would justify the intervention. The results show how this situation has affected the design strategies and sizing of the ventilated air cavities, limiting in many cases their efficiency.

  18. Ten-year monitoring of high-rise building columns using long-gauge fiber optic sensors

    International Nuclear Information System (INIS)

    Glisic, B; Inaudi, D; Lau, J M; Fong, C C

    2013-01-01

    A large-scale lifetime building monitoring program was implemented in Singapore in 2001. The monitoring aims of this unique program were to increase safety, verify performance, control quality, increase knowledge, optimize maintenance costs, and evaluate the condition of the structures after a hazardous event. The first instrumented building, which has now been monitored for more than ten years, is presented in this paper. The long-gauge fiber optic strain sensors were embedded in fresh concrete of ground-level columns, thus the monitoring started at the birth of both the construction material and the structure. Measurement sessions were performed during construction, upon completion of each new story and the roof, and after the construction, i.e., in-service. Based on results it was possible to follow and evaluate long-term behavior of the building through every stage of its life. The results of monitoring were analyzed at a local (column) and global (building) level. Over-dimensioning of one column was identified. Differential settlement of foundations was detected, localized, and its magnitude estimated. Post-tremor analysis was performed. Real long-term behavior of concrete columns was assessed. Finally, the long-term performance of the monitoring system was evaluated. The researched monitoring method, monitoring system, rich results gathered over approximately ten years, data analysis algorithms, and the conclusions on the structural behavior and health condition of the building based on monitoring are presented in this paper. (paper)

  19. Ten-year monitoring of high-rise building columns using long-gauge fiber optic sensors

    Science.gov (United States)

    Glisic, B.; Inaudi, D.; Lau, J. M.; Fong, C. C.

    2013-05-01

    A large-scale lifetime building monitoring program was implemented in Singapore in 2001. The monitoring aims of this unique program were to increase safety, verify performance, control quality, increase knowledge, optimize maintenance costs, and evaluate the condition of the structures after a hazardous event. The first instrumented building, which has now been monitored for more than ten years, is presented in this paper. The long-gauge fiber optic strain sensors were embedded in fresh concrete of ground-level columns, thus the monitoring started at the birth of both the construction material and the structure. Measurement sessions were performed during construction, upon completion of each new story and the roof, and after the construction, i.e., in-service. Based on results it was possible to follow and evaluate long-term behavior of the building through every stage of its life. The results of monitoring were analyzed at a local (column) and global (building) level. Over-dimensioning of one column was identified. Differential settlement of foundations was detected, localized, and its magnitude estimated. Post-tremor analysis was performed. Real long-term behavior of concrete columns was assessed. Finally, the long-term performance of the monitoring system was evaluated. The researched monitoring method, monitoring system, rich results gathered over approximately ten years, data analysis algorithms, and the conclusions on the structural behavior and health condition of the building based on monitoring are presented in this paper.

  20. Design and development of Building energy simulation Software for prefabricated cabin type of industrial building (PCES)

    Science.gov (United States)

    Zhang, Jun; Li, Ri Yi

    2018-06-01

    Building energy simulation is an important supporting tool for green building design and building energy consumption assessment, At present, Building energy simulation software can't meet the needs of energy consumption analysis and cabinet level micro environment control design of prefabricated building. thermal physical model of prefabricated building is proposed in this paper, based on the physical model, the energy consumption calculation software of prefabricated cabin building(PCES) is developed. we can achieve building parameter setting, energy consumption simulation and building thermal process and energy consumption analysis by PCES.

  1. Sacramento Municipal Utility district's interim onsite storage building for low level radioactive waste

    International Nuclear Information System (INIS)

    Gillis, E.

    1986-01-01

    In order to meet current and anticipated needs for the low level radwaste management program at the Rancho Seco Nuclear Generating Station, the Sacramento Municipal Utility District has a design and construction program underway which will provide an onsite interim storage facility that can be expanded in two and one-half year increments. The design approach utilized allows capital investment to be minimized and still provides radwaste management flexibility in anticipation of delays in resolution of the nationwide long term radwaste disposal situation. The facility provides storage and material accountability for all low level radwastes generated by the plant. Wastes are segregated by radioactivity level and are stored in two separate storage areas located within one facility. Lower activity wastes are stored in a lightly shielded structure and handled by lift trucks, while the higher activity wastes are stored in a highly shielded structure and handled remotely by manual bridge crane. The layout of the structure provides for economy of operation and minimizes personnel radiation exposure. Design philosophy and criteria, building layout and systems, estimated costs and construction schedule are discussed

  2. Maintaining reduced noise levels in a resource-constrained neonatal intensive care unit by operant conditioning.

    Science.gov (United States)

    Ramesh, A; Denzil, S B; Linda, R; Josephine, P K; Nagapoornima, M; Suman Rao, P N; Swarna Rekha, A

    2013-03-01

    To evaluate the efficacy of operant conditioning in sustaining reduced noise levels in the neonatal intensive care unit (NICU). Quasi-experimental study on quality of care. Level III NICU of a teaching hospital in south India. 26 staff employed in the NICU. (7 Doctors, 13 Nursing staff and 6 Nursing assistants). Operant conditioning of staff activity for 6 months. This method involves positive and negative reinforcement to condition the staff to modify noise generating activities. Comparing noise levels in decibel: A weighted [dB (A)] before conditioning with levels at 18 and 24 months after conditioning. Decibel: A weighted accounts for noise that is audible to human ears. Operant conditioning for 6 months sustains the reduced noise levels to within 62 dB in ventilator room 95% CI: 60.4 - 62.2 and isolation room (95% CI: 55.8 - 61.5). In the preterm room, noise can be maintained within 52 dB (95% CI: 50.8 - 52.6). This effect is statistically significant in all the rooms at 18 months (P = 0.001). At 24 months post conditioning there is a significant rebound of noise levels by 8.6, 6.7 and 9.9 dB in the ventilator, isolation and preterm room, respectively (P =0.001). Operant conditioning for 6 months was effective in sustaining reduced noise levels. At 18 months post conditioning, the noise levels were maintained within 62 dB (A), 60 dB (A) and 52 dB (A) in the ventilator, isolation and pre-term room, respectively. Conditioning needs to be repeated at 12 months in the ventilator room and at 18 months in the other rooms.

  3. Evaluation of Respondent-Driven Sampling

    Science.gov (United States)

    McCreesh, Nicky; Frost, Simon; Seeley, Janet; Katongole, Joseph; Tarsh, Matilda Ndagire; Ndunguse, Richard; Jichi, Fatima; Lunel, Natasha L; Maher, Dermot; Johnston, Lisa G; Sonnenberg, Pam; Copas, Andrew J; Hayes, Richard J; White, Richard G

    2012-01-01

    Background Respondent-driven sampling is a novel variant of link-tracing sampling for estimating the characteristics of hard-to-reach groups, such as HIV prevalence in sex-workers. Despite its use by leading health organizations, the performance of this method in realistic situations is still largely unknown. We evaluated respondent-driven sampling by comparing estimates from a respondent-driven sampling survey with total-population data. Methods Total-population data on age, tribe, religion, socioeconomic status, sexual activity and HIV status were available on a population of 2402 male household-heads from an open cohort in rural Uganda. A respondent-driven sampling (RDS) survey was carried out in this population, employing current methods of sampling (RDS sample) and statistical inference (RDS estimates). Analyses were carried out for the full RDS sample and then repeated for the first 250 recruits (small sample). Results We recruited 927 household-heads. Full and small RDS samples were largely representative of the total population, but both samples under-represented men who were younger, of higher socioeconomic status, and with unknown sexual activity and HIV status. Respondent-driven-sampling statistical-inference methods failed to reduce these biases. Only 31%-37% (depending on method and sample size) of RDS estimates were closer to the true population proportions than the RDS sample proportions. Only 50%-74% of respondent-driven-sampling bootstrap 95% confidence intervals included the population proportion. Conclusions Respondent-driven sampling produced a generally representative sample of this well-connected non-hidden population. However, current respondent-driven-sampling inference methods failed to reduce bias when it occurred. Whether the data required to remove bias and measure precision can be collected in a respondent-driven sampling survey is unresolved. Respondent-driven sampling should be regarded as a (potentially superior) form of convenience

  4. Evaluation of respondent-driven sampling.

    Science.gov (United States)

    McCreesh, Nicky; Frost, Simon D W; Seeley, Janet; Katongole, Joseph; Tarsh, Matilda N; Ndunguse, Richard; Jichi, Fatima; Lunel, Natasha L; Maher, Dermot; Johnston, Lisa G; Sonnenberg, Pam; Copas, Andrew J; Hayes, Richard J; White, Richard G

    2012-01-01

    Respondent-driven sampling is a novel variant of link-tracing sampling for estimating the characteristics of hard-to-reach groups, such as HIV prevalence in sex workers. Despite its use by leading health organizations, the performance of this method in realistic situations is still largely unknown. We evaluated respondent-driven sampling by comparing estimates from a respondent-driven sampling survey with total population data. Total population data on age, tribe, religion, socioeconomic status, sexual activity, and HIV status were available on a population of 2402 male household heads from an open cohort in rural Uganda. A respondent-driven sampling (RDS) survey was carried out in this population, using current methods of sampling (RDS sample) and statistical inference (RDS estimates). Analyses were carried out for the full RDS sample and then repeated for the first 250 recruits (small sample). We recruited 927 household heads. Full and small RDS samples were largely representative of the total population, but both samples underrepresented men who were younger, of higher socioeconomic status, and with unknown sexual activity and HIV status. Respondent-driven sampling statistical inference methods failed to reduce these biases. Only 31%-37% (depending on method and sample size) of RDS estimates were closer to the true population proportions than the RDS sample proportions. Only 50%-74% of respondent-driven sampling bootstrap 95% confidence intervals included the population proportion. Respondent-driven sampling produced a generally representative sample of this well-connected nonhidden population. However, current respondent-driven sampling inference methods failed to reduce bias when it occurred. Whether the data required to remove bias and measure precision can be collected in a respondent-driven sampling survey is unresolved. Respondent-driven sampling should be regarded as a (potentially superior) form of convenience sampling method, and caution is required

  5. Vibration characteristics of an APS lab facility in Building 401

    International Nuclear Information System (INIS)

    Royston, T.J.

    1998-01-01

    The vibratory behavior of a lab facility located in Building 401 of the Advanced Photon Source site at Argonne National Laboratory is summarized. Measurements of ambient vibration indicate that acceptable displacement levels are usually maintained (rms value below 0.1 microns) for the measured frequency range, above 0.2 Hz. An exception occurs when strong wind conditions excite a horizontal building resonance near 1.85 Hz to rms levels as high as 0.3 microns. Measurements of the laboratory floor's dynamic response to directly applied force excitation agree with theoretical predictions. The primary component of the floor construction is a reinforced concrete slab. The slab has a transverse fundamental resonant frequency of 18.5 Hz and an associated damping level of roughly 8.5% of critical. It is also shown via experimental measurements that the linoleum surface adhered to the concrete slab is far more compliant than the slab itself and can significantly influence the floor's dynamic response to local excitations

  6. Modeling temperature and moisture fields in conditioned spaces using zonal approach, including sorption phenomena in buildings materials; Modelisation thermo-hydro-aeraulique des locaux climatises selon l'approche zonale (prise en compte des phenomenes de sorption d'humidite)

    Energy Technology Data Exchange (ETDEWEB)

    Cordeiro Mendoca, K.

    2004-05-15

    Building simulation models represent in our days an important tool for building conception and performance analysis. Although moisture interacts in many ways with the whole building affecting therefore its behavior, frequently these models neglects the interactions between them. In addition, in most of them, indoor air conditions are considered uniform, which is a non-realistic assumption in conditioned spaces. In this work, a model to predict temperature and moisture fields in conditioned spaces, using zonal approach, is proposed. This method is based in dividing spatially a room in a relative small number of zones, typically on the order of tens to hundreds, where the state variables of air are considered uniform, with the exception of pressure that varies hydrostatically. While not as fine-grained as CFD simulation, zonal models do give useful information about temperature and moisture distributions that is important in comfort analysis. The proposed model was structured in three groups of sub-models representing the three building domains: indoor air, envelope and HVAC system. The indoor air sub-model is related to the indoor air space, where airflow speed can be considered weak. The envelope sub-model is related to the radiation exchanges between envelope and its neighborhood, and to the simultaneous heat and mass transfers across the envelope material. This latest can be represented by four sub-models of different complexity levels, with two of them taking into account moisture adsorption and desorption by building materials. Concerning to the HVAC system model, it refers to the whole system that means equipment, control and specific airflow from equipment. All sub-models were coupled into a modular simulation environment, SPARK, well-adapted to compare different models. The applicability of the proposed model is shown by two examples. The first one shows the importance of considering moisture sorption phenomena in the prediction of indoor air conditions

  7. Indoor Noise Loading in Residential Prefabricated Buildings

    Science.gov (United States)

    Kraus, Michal; Juhásová Šenitková, Ingrid

    2017-10-01

    Quality on indoor environment is among others also defined by an acoustic comfort and noise emissions. The indoor noise loading in the residential prefabricated buildings is specific problem related to structural design of these buildings. Problems with noise level of sanitary systems are mostly associated with hydraulic shock such as water distribution and sewage drainage. Another very common cause of excessive noise is also flushing the toilet or water fall on enamelled steel (bath or shower). This paper aims to analyse the acoustic properties in the residential prefabricated buildings. Sanitary core of the assessed apartment is in original condition without any alterations. The sanitary core is based on a formica (high-pressure laminate). The study discusses the maximum sound levels in the three assessed rooms for the three different noise sources. The values of maximum noise level are measured for the corridor, bedroom and living room. Sources of noise are common activities relating to the operation of sanitary core - the toilet flush in the toilet, falling water from the shower in the bathroom and the water falling on the bottom of the kitchen sink in the kitchen. Other sources of noise are eliminated or minimized during the experiment. The digital sound level meter Testo 815 is used for measurements. The measured values of maximum sound level LA,max [dB] are adjusted by the correction coefficient. The obtained values are compared with the hygienic limits for day and night period. Night hygienic limit (30 dB) is exceeded in all the rooms for all noise sources. This limit is exceeded from 17 to 73%. The values in the bedroom and the living room meet the daily hygienic limit (40 dB). The daily limit is exceeded only in the corridor. The highest values of noise are identified for the toilet flushing.

  8. Using respondent uncertainty to mitigate hypothetical bias in a stated choice experiment

    Science.gov (United States)

    Richard C. Ready; Patricia A. Champ; Jennifer L. Lawton

    2010-01-01

    In a choice experiment study, willingness to pay for a public good estimated from hypothetical choices was three times as large as willingness to pay estimated from choices requiring actual payment. This hypothetical bias was related to the stated level of certainty of respondents. We develop protocols to measure respondent certainty in the context of a choice...

  9. Predictors of summertime heat index levels in New York City apartments.

    Science.gov (United States)

    Quinn, A; Kinney, P; Shaman, J

    2017-07-01

    During heat waves, fatal overexposure to heat most often occurs at home. It is not known how factors such as building size, floor level, and different types of air conditioning (AC) contribute to excess indoor heat. We monitored indoor temperature and humidity in 36 apartments in New York City during summers 2014 and 2015 and used these values to calculate the indoor heat index (HI). We investigated the role of AC type and building-level factors on indoor HI using multilevel regression models. Thirty-four of 36 homes had AC. Central and ductless AC types were associated with the coolest indoor conditions; homes with window and portable AC were significantly warmer. Apartments on the top floor of a building were significantly hotter during heat advisory periods than other apartments regardless of the presence of AC. High indoor HI levels persisted in some homes for approximately 1 day following the end of the two heat advisory periods. We provide concrete evidence of higher heat levels in top floor apartments and in homes with certain types of AC. High heat levels that persist indoors after outdoor heat has subsided may present an underappreciated public health risk. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. System for indicating the level of material in a container

    International Nuclear Information System (INIS)

    Erb, T.L.

    1980-01-01

    In a radiation detecting system for controlling the level of material in a container, the first counter accumulates pulses generated by a geiger tube at a rate related to the level of material and a second counter accumulates clock pulses. A race condition is established between a NAND circuit indicating that the first counter has reached a predetermined total, and a NAND circuit indicating that the second counter has reached a second predetermined total representing a fixed counting interval. The first NAND circuit to respond to its predetermined total actuates a circuit to reset both counters and, if indicative of the material level being below a predetermined minimum, actuates an alarm or operates a control circuit to add material to the container. In the example shown, an additional NAND circuit responds to a different count in the first counter which count in the same time interval corresponds to a higher level, and when material is being added to the container, the race condition is between two NAND circuits. The effect of this is to provide a hysteresis effect preventing the circuit from 'hunting' around one level of material. (author)

  11. 105-C Building characterization survey data report

    International Nuclear Information System (INIS)

    Miller, R.L.

    1997-01-01

    This report is a compilation of the 105-C Facility Characterization Survey data collected during the period of July 1, 1994, through September 30, 1994. The scope of the report is limited to the characterization of the 105-C Facility and surrounding site. Conclusions and recommendations regarding courses of future action are beyond the scope of this report. The survey data in this report reflects the current conditions and status of the 105-C Building, and is intended to be used in support of future decontamination and decommissioning activities. The survey was organized and implemented to evaluate the four parameters relating to the current condition of the facility. These parameters concern the physical conditions of the 105-C Building from a personnel safety standpoint; the radiological status throughout the building; identification of the hazardous materials located in the building; and identification of subsurface obstacles left in the path of proposed excavations

  12. Natural ventilation of buildings: opposing wind and buoyancy

    Science.gov (United States)

    Linden, Paul; Hunt, Gary

    1998-11-01

    The use of natural ventilation in buildings is an attractive way to reduce energy usage thereby reducing costs and CO2 emissions. Generally, it is necessary to remove excess heat from a building and the designer can use the buoyancy forces associated with the above ambient temperatures within the building to drive a flow - 'stack' ventilation. The most efficient mode is displacement ventilation where warm air accumulates near the top of the building and flows out through upper level vents and cooler air flows in at lower levels. Ventilation will also be driven between these lower and upper openings by the wind. We report on laboratory modeling and theory which investigates the effects of an opposing wind on stack ventilation driven by a constant source of heat within a space under displacement ventilation. We show that there is a critical wind speed, expressed in dimensionless terms as a critical Froude number, above which displacement ventilation is replaced by (less efficient) mixing ventilation with reversed flow. Below this critical speed, displacement ventilation, in which the interior has a two-layer stratification, is maintained. The criterion for the change in ventilation mode is derived from general considerations of mixing efficiencies in stratified flows. We conclude that even when wind effects might appear to be dominant, the inhibition of mixing by the stable stratification within the space ensures that stack ventilation can operate over a wide range of apparently adverse conditions.

  13. Strategies for Demand Response in Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Watson, David S.; Kiliccote, Sila; Motegi, Naoya; Piette, Mary Ann

    2006-06-20

    This paper describes strategies that can be used in commercial buildings to temporarily reduce electric load in response to electric grid emergencies in which supplies are limited or in response to high prices that would be incurred if these strategies were not employed. The demand response strategies discussed herein are based on the results of three years of automated demand response field tests in which 28 commercial facilities with an occupied area totaling over 11 million ft{sup 2} were tested. Although the demand response events in the field tests were initiated remotely and performed automatically, the strategies used could also be initiated by on-site building operators and performed manually, if desired. While energy efficiency measures can be used during normal building operations, demand response measures are transient; they are employed to produce a temporary reduction in demand. Demand response strategies achieve reductions in electric demand by temporarily reducing the level of service in facilities. Heating ventilating and air conditioning (HVAC) and lighting are the systems most commonly adjusted for demand response in commercial buildings. The goal of demand response strategies is to meet the electric shed savings targets while minimizing any negative impacts on the occupants of the buildings or the processes that they perform. Occupant complaints were minimal in the field tests. In some cases, ''reductions'' in service level actually improved occupant comfort or productivity. In other cases, permanent improvements in efficiency were discovered through the planning and implementation of ''temporary'' demand response strategies. The DR strategies that are available to a given facility are based on factors such as the type of HVAC, lighting and energy management and control systems (EMCS) installed at the site.

  14. Experimental and analytical studies of a deeply embedded reactor building model considering soil-building interaction. Pt. 1

    International Nuclear Information System (INIS)

    Tanaka, H.; Ohta, T.; Uchiyama, S.

    1979-01-01

    The purpose of this paper is to describe the dynamic characteristics of a deeply embedded reactor building model derived from experimental and analytical studies which considers soil-building interaction behaviour. The model building is made of reinforced concrete. It has two stories above ground level and a basement, resting on sandy gravel layer at a depth of 3 meters. The backfill around the building was made to ground level. The model building is simplified and reduced to about one-fifteenth (1/15) of the prototype. It has bearing wall system for the basement and the first story, and frame system for the second. (orig.)

  15. Creating high performance buildings: Lower energy, better comfort

    International Nuclear Information System (INIS)

    Brager, Gail; Arens, Edward

    2015-01-01

    Buildings play a critical role in the challenge of mitigating and adapting to climate change. It is estimated that buildings contribute 39% of the total U.S. greenhouse gas (GHG) emissions [1] primarily due to their operational energy use, and about 80% of this building energy use is for heating, cooling, ventilating, and lighting. An important premise of this paper is about the connection between energy and comfort. They are inseparable when one talks about high performance buildings. Worldwide data suggests that we are significantly overcooling buildings in the summer, resulting in increased energy use and problems with thermal comfort. In contrast, in naturally ventilated buildings without mechanical cooling, people are comfortable in much warmer temperatures due to shifting expectations and preferences as a result of occupants having a greater degree of personal control over their thermal environment; they have also become more accustomed to variable conditions that closely reflect the natural rhythms of outdoor climate patterns. This has resulted in an adaptive comfort zone that offers significant potential for encouraging naturally ventilated buildings to improve both energy use and comfort. Research on other forms for providing individualized control through low-energy personal comfort systems (desktop fans, foot warmed, and heated and cooled chairs) have also demonstrated enormous potential for improving both energy and comfort performance. Studies have demonstrated high levels of comfort with these systems while ambient temperatures ranged from 64–84°F. Energy and indoor environmental quality are inextricably linked, and must both be important goals of a high performance building

  16. Energy Efficiency Building Systems Regional Innovation Cluster Initiative

    Energy Technology Data Exchange (ETDEWEB)

    Krebs, Martha [Pennsylvania State Univ., University Park, PA (United States)

    2016-07-29

    The Consortium for Building Energy Innovation (CBEI) was established through a Funding Opportunity Announcement led by the U.S. Department of Energy, under a cooperative agreement managed by the National Energy Technology Laboratory. CBEI is led by The Pennsylvania State University and is composed of partners from academia, the private sector, and economic development agencies. The Consortium has included as many as 24 different partners over the five years, but 14 have been core to the work over the five year cooperative agreement. CBEI primarily focused on developing energy efficiency solutions for the small and medium commercial building market, with a focus on buildings less than 50,000 square feet. This market has been underserved by the energy efficiency industry, which has focused on larger commercial buildings where the scale of an individual retrofit lends itself to the use of sophisticated modeling tools and more advanced solutions. Owners/operators and retrofit providers for larger buildings have a greater level of understanding of, and experience with different solutions. In contrast, smaller commercial building retrofits, like residential retrofits, often have owners with less knowledge about energy management and less time to learn about it. This market segment is also served by retrofit providers that are smaller and often focused on particular building systems, e.g. heating, ventilation and air conditioning (HVAC), lighting, roofing, or insulation. The size of a smaller commercial building retrofit does not lend itself, from a cost perspective, to the application of multiple, sophisticated design and modeling tools, which means that they are less likely to have integrated solutions.

  17. Measurement of heat stress conditions at cow level and comparison to climate conditions at stationary locations inside a dairy barn.

    Science.gov (United States)

    Schüller, Laura K; Heuwieser, Wolfgang

    2016-08-01

    The objectives of this study were to examine heat stress conditions at cow level and to investigate the relationship to the climate conditions at 5 different stationary locations inside a dairy barn. In addition, we compared the climate conditions at cow level between primiparous and multiparous cows for a period of 1 week after regrouping. The temperature-humidity index (THI) differed significantly between all stationary loggers. The lowest THI was measured at the window logger in the experimental stall and the highest THI was measured at the central logger in the experimental stall. The THI at the mobile cow loggers was 2·33 THI points higher than at the stationary loggers. Furthermore, the mean daily THI was higher at the mobile cow loggers than at the stationary loggers on all experimental days. The THI in the experimental pen was 0·44 THI points lower when the experimental cow group was located inside the milking parlour. The THI measured at the mobile cow loggers was 1·63 THI points higher when the experimental cow group was located inside the milking parlour. However, there was no significant difference for all climate variables between primiparous and multiparous cows. These results indicate, there is a wide range of climate conditions inside a dairy barn and especially areas with a great distance to a fresh air supply have an increased risk for the occurrence of heat stress conditions. Furthermore, the heat stress conditions are even higher at cow level and cows not only influence their climatic environment, but also generate microclimates within different locations inside the barn. Therefore climate conditions should be obtained at cow level to evaluate the heat stress conditions that dairy cows are actually exposed to.

  18. 77 FR 6585 - Proposed Information Collection Request (ICR) for the Impact Evaluation of the YouthBuild Program...

    Science.gov (United States)

    2012-02-08

    ... job characteristics? What are YouthBuild's impacts on crime and delinquency? What are the program's... (ICR) for the Impact Evaluation of the YouthBuild Program; New Collection AGENCY: Employment and... instruments are clearly understood, and the impact of collection requirements on respondents can be properly...

  19. 29 CFR 98.1000 - Respondent.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Respondent. 98.1000 Section 98.1000 Labor Office of the Secretary of Labor GOVERNMENTWIDE DEBARMENT AND SUSPENSION (NONPROCUREMENT) Definitions § 98.1000 Respondent. Respondent means a person against whom an agency has initiated a debarment or suspension action. ...

  20. Transcriptomics reveal transgenerational effects in purple sea urchin embryos: Adult acclimation to upwelling conditions alters the response of their progeny to differential pCO2 levels.

    Science.gov (United States)

    Wong, Juliet M; Johnson, Kevin M; Kelly, Morgan W; Hofmann, Gretchen E

    2018-03-01

    Understanding the mechanisms with which organisms can respond to a rapidly changing ocean is an important research priority in marine sciences, especially in the light of recent predictions regarding the pace of ocean change in the coming decades. Transgenerational effects, in which the experience of the parental generation can shape the phenotype of their offspring, may serve as such a mechanism. In this study, adult purple sea urchins, Strongylocentrotus purpuratus, were conditioned to regionally and ecologically relevant pCO 2 levels and temperatures representative of upwelling (colder temperature and high pCO 2 ) and nonupwelling (average temperature and low pCO 2 ) conditions typical of coastal upwelling regions in the California Current System. Following 4.5 months of conditioning, adults were spawned and offspring were raised under either high or low pCO 2 levels, to examine the role of maternal effects. Using RNA-seq and comparative transcriptomics, our results indicate that differential conditioning of the adults had an effect on the gene expression patterns of the progeny during the gastrula stage of early development. For example, maternal conditioning under upwelling conditions intensified the transcriptomic response of the progeny when they were raised under high versus low pCO 2 conditions. Additionally, mothers that experienced upwelling conditions produced larger progeny. The overall findings of this study are complex, but do suggest that transgenerational plasticity in situ could act as an important mechanism by which populations might keep pace with rapid environmental change. © 2018 John Wiley & Sons Ltd.

  1. Amitriptyline converts non-responders into responders to low-frequency electroacupuncture-induced analgesia in rats.

    Science.gov (United States)

    Fais, Rafael S; Reis, G M; Rossaneis, A C; Silveira, J W S; Dias, Q M; Prado, W A

    2012-07-26

    The purpose of this study was to examine whether the use of intraperitoneal or intrathecal amitriptyline combined with electroacupuncture modifies the tail-flick reflex and incision pain in rats that normally do not have analgesia to electroacupuncture in the tail-flick test (non-responder rats). Changes in the nociceptive threshold of intraperitoneal or intrathecal saline- or amitriptyline-treated non-responder rats were evaluated using the tail-flick or incision pain tests before, during and after a 20-min period of electroacupuncture, applied at 2 Hz to the Zusanli and Sanynjiao acupoints. Amitriptyline was used at doses of 0.8 mg/kg or 30 μg/kg by intraperitoneal or intrathecal route, respectively. At these doses, amitriptyline has no effect against thermal or incision pain in rats. Rats selected as non-responders to the analgesic effect of electroacupuncture 2 Hz in tail-flick and incision pain tests become responders after an intraperitoneal or intrathecal injection of amitriptyline. Amitriptyline converts non-responder rats to rats that respond to electroacupuncture with analgesia in a model of thermal phasic pain and anti-hyperalgesia in a model of incision pain. Copyright © 2012 Elsevier Inc. All rights reserved.

  2. Methods and apparatus for managing corrosion in buildings

    Science.gov (United States)

    Chey, S Jay; Hamann, Hendrik F; Klein, Levente Ioan; Schappert, Michael Alan; Stepanchuk, Andriy

    2015-02-03

    Principles of the invention provide methods and apparatus for providing corrosion management in buildings. In one aspect, an exemplary method includes the step of receiving first data relating corrosion rate to a plurality of environmental conditions. This first data is subsequently utilized to determine a quantitative relationship between corrosion rate and the plurality of environmental conditions. In another step, second data indicative of one or more environmental conditions within a building is received. A corrosion rate in the building is then determined at least in part by applying the determined quantitative relationship to this second data.

  3. Microclimatic conditions at the external surface of building envelopes

    Energy Technology Data Exchange (ETDEWEB)

    Kragh, M.K.

    1998-12-31

    The project is described, the motivation for the research and the microclimate is defined in relation to both building physics research and applications. Air temperatur, air humidity, solar radiation and air velocity are briefly considered, whilst driving rain and long-wave radiation are described in more detail. Convective heat transfer and surface coefficients are discussed, although they are not microclimatic factors, merely resulting from combinations of such factors. They are included as they are important in relation to transfer of heat and moisture at the surface of the building envelope. Driving rain measurement is the main area of interest, including development of measurement equipment. Long-wave irradiation is measured and compared with empirical formulae from the literature. Window convection heat transfer is another main area of interest. Nocturnal convective heat transfer from a double pane glazing is studied and measurement principles are discussed. Finally, a compilation of meteorological data for hygrothermal simulations, including estimation of driving rain, is described. System error estimation in relation to the window convection measurements, design notes on an apparatus for external convection measurement, formulae for conversion of relative humitity and dry-bulb temperature into dew point temperature. (EG) 66 refs.

  4. Microclimatic conditions at the external surface of building envelopes

    Energy Technology Data Exchange (ETDEWEB)

    Kragh, M K

    1999-12-31

    The project is described, the motivation for the research and the microclimate is defined in relation to both building physics research and applications. Air temperatur, air humidity, solar radiation and air velocity are briefly considered, whilst driving rain and long-wave radiation are described in more detail. Convective heat transfer and surface coefficients are discussed, although they are not microclimatic factors, merely resulting from combinations of such factors. They are included as they are important in relation to transfer of heat and moisture at the surface of the building envelope. Driving rain measurement is the main area of interest, including development of measurement equipment. Long-wave irradiation is measured and compared with empirical formulae from the literature. Window convection heat transfer is another main area of interest. Nocturnal convective heat transfer from a double pane glazing is studied and measurement principles are discussed. Finally, a compilation of meteorological data for hygrothermal simulations, including estimation of driving rain, is described. System error estimation in relation to the window convection measurements, design notes on an apparatus for external convection measurement, formulae for conversion of relative humitity and dry-bulb temperature into dew point temperature. (EG) 66 refs.

  5. Orbitofrontal participation in sign- and goal-tracking conditioned responses: Effects of nicotine.

    Science.gov (United States)

    Stringfield, Sierra J; Palmatier, Matthew I; Boettiger, Charlotte A; Robinson, Donita L

    2017-04-01

    Pavlovian conditioned stimuli can acquire incentive motivational properties, and this phenomenon can be measured in animals using Pavlovian conditioned approach behavior. Drugs of abuse can influence the expression of this behavior, and nicotine in particular exhibits incentive amplifying effects. Both conditioned approach behavior and drug abuse rely on overlapping corticolimbic circuitry. We hypothesize that the orbitofrontal cortex (OFC) regulates conditioned approach, and that one site of nicotine action is in the OFC where it reduces cortical output. To test this, we repeatedly exposed rats to 0.4 mg/kg nicotine (s.c.) during training and then pharmacologically inactivated the lateral OFC or performed in vivo electrophysiological recordings of lateral OFC neurons in the presence or absence of nicotine. In Experiment 1, animals were trained in a Pavlovian conditioning paradigm and behavior was evaluated after inactivation of the OFC by microinfusion of the GABA agonists baclofen and muscimol. In Experiment 2, we monitored phasic firing of OFC neurons during Pavlovian conditioning sessions. Nicotine reliably enhanced conditioned responding to the conditioned cue, and inactivation of the OFC reduced conditioned responding, especially the sign-tracking response. OFC neurons exhibited phasic excitations to cue presentation and during goal tracking, and nicotine acutely blunted this phasic neuronal firing. When nicotine was withheld, both conditioned responding and phasic firing in the OFC returned to the level of controls. These results suggest that the OFC is recruited for the expression of conditioned responses, and that nicotine acutely influences this behavior by reducing phasic firing in the OFC. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Dynamic containment of gaseous effluents in the auxiliary buildings and reinjection of liquid effluents from these buildings back into the reactor building for 900 MWe PWRs under accident condition

    International Nuclear Information System (INIS)

    Demoulin, F.; Collinet, J.; Nguyen, C.

    1987-04-01

    Examination of the lessons to be learned from the accident of the Three Mile Island nuclear power plant on 20 March 1979 led the French Safety Authorities and EDF (Electricite de France) to adopt a series of measures intended to improve the performance of the containment of French PWRs, especially in the event of accident. Among the measures adopted, two of them contribute to the upgrading of the containment of nuclear island buildings, by reducing radioactivity constraints inside these buildings and by limiting radioactive releases into the environment. These are: (1) dynamic containment of auxiliary buildings likely to be contaminated following an accident, (2) reinjection back into the reactor building of liquid effluents arising in the auxiliary buildings. In this paper we shall discuss, for each measure, the approach to the problem and describe the arrangements made to arrive at a satisfactory solution [fr

  7. Responding to the challenge : the Climate Change Action Fund (CCAF) 1998-2001 report

    International Nuclear Information System (INIS)

    2001-01-01

    In 1998, the government of Canada responded to the challenges of climate change and created the Climate Change Action Fund (CCAF) to help develop a national implementation strategy on climate change and to support early action. With the first three year phase of the CCAF complete and a new phase about to begin, this report describes the progress and achievements of the first phase of the CCAF. Results are described for the following distinct components of the CCAF: (1) foundation building, (2) technology early action measures (TEAM); science, impacts and adaptation (SIA), and public education and outreach (PEO). The government allocated $150 million over three years to accomplish goals within these four groups. Accomplishing the goals involved building on existing programs and establishing partnerships on climate change with provinces, territories and stakeholders. The report listed several general achievements in each of the four groups. The second phase of the CCAF is underway with an added fifth group to bring focus to the international aspects of the climate change issue so that Canada's vulnerabilities to climate change are better defined and opportunities are identified. The foundation building block has also been renamed. The five new blocks are called: (1) building on the future, (2) technology early action measures (TEAM), (3) science, impacts and adaptation (4) impacts and adaptation, and (5) public education and outreach. 1 tab., 1 fig

  8. Being the Change: An Inner City School Builds Peace

    Science.gov (United States)

    Curry, Marnie W.

    2014-01-01

    This article describes an urban high school's response to gun violence, chronicling how the school's mission, full-service community orientation, and commitment to authentic cariño (caring) allowed students to respond to grief and tragedy and develop an ongoing peace building movement that seeks to transform students' lives and the communities…

  9. Aerial Imagery and LIDAR Data Fusion for Unambiguous Extraction of Adjacent Level-Buildings Footprints

    Science.gov (United States)

    Mola Ebrahimi, S.; Arefi, H.; Rasti Veis, H.

    2017-09-01

    Our paper aims to present a new approach to identify and extract building footprints using aerial images and LiDAR data. Employing an edge detector algorithm, our method first extracts the outer boundary of buildings, and then by taking advantage of Hough transform and extracting the boundary of connected buildings in a building block, it extracts building footprints located in each block. The proposed method first recognizes the predominant leading orientation of a building block using Hough transform, and then rotates the block according to the inverted complement of the dominant line's angle. Therefore the block poses horizontally. Afterwards, by use of another Hough transform, vertical lines, which might be the building boundaries of interest, are extracted and the final building footprints within a block are obtained. The proposed algorithm is implemented and tested on the urban area of Zeebruges, Belgium(IEEE Contest,2015). The areas of extracted footprints are compared to the corresponding areas in the reference data and mean error is equal to 7.43 m2. Besides, qualitative and quantitative evaluations suggest that the proposed algorithm leads to acceptable results in automated precise extraction of building footprints.

  10. A high-speed DAQ framework for future high-level trigger and event building clusters

    International Nuclear Information System (INIS)

    Caselle, M.; Perez, L.E. Ardila; Balzer, M.; Dritschler, T.; Kopmann, A.; Mohr, H.; Rota, L.; Vogelgesang, M.; Weber, M.

    2017-01-01

    Modern data acquisition and trigger systems require a throughput of several GB/s and latencies of the order of microseconds. To satisfy such requirements, a heterogeneous readout system based on FPGA readout cards and GPU-based computing nodes coupled by InfiniBand has been developed. The incoming data from the back-end electronics is delivered directly into the internal memory of GPUs through a dedicated peer-to-peer PCIe communication. High performance DMA engines have been developed for direct communication between FPGAs and GPUs using 'DirectGMA (AMD)' and 'GPUDirect (NVIDIA)' technologies. The proposed infrastructure is a candidate for future generations of event building clusters, high-level trigger filter farms and low-level trigger system. In this paper the heterogeneous FPGA-GPU architecture will be presented and its performance be discussed.

  11. Hip fractures and area level socioeconomic conditions: a population-based study

    Directory of Open Access Journals (Sweden)

    Rapp Kilian

    2009-04-01

    Full Text Available Abstract Background Only a limited number of studies have analyzed the association between hip fracture incidence and socioeconomic conditions. Most, but not all found an association, and results are in part conflicting. The aim of our study was to evaluate the association between hip fractures and socioeconomic conditions in Germany, from 1995 to 2004, on a census tract area level. Methods We used data from the national hospital discharge diagnosis register and data on socioeconomic and demographic characteristics of 131 census tracts from official statistics. Associations between the hip fracture incidence and socioeconomic conditions were analyzed by multiple Poisson regression models, taking overdispersion into account. Results The risk of hip fracture decreased by 4% with a 7% increase (about one interquartile range of non-German nationals. It decreased by 10% with a 6% increased rate of unemployment, increased by 7% with a 2% increase of the proportion of welfare recipients, and also increased by 3% with an increase of the proportion of single parent families of 1.9%. Conclusion Our results showed weak associations between indicators of socioeconomic conditions at area level and hip fracture risk; the varied by type of indicator. We conclude that hip fracture incidence might be influenced by the socioeconomic context of a region, but further analysis using more specific markers for deprivation on a smaller scale and individual-level data are needed.

  12. Comparison of Buildings\\' Thermal Loads against Building Orientations for Sustainable Housing in Pakistan

    Directory of Open Access Journals (Sweden)

    Arif Khan

    2012-07-01

    Full Text Available As the sustainable settlements have been included as a vital end product of all planning exercises, the architectural layouts should be well integrated with the sun path charts and the orientations of windows. Appropriate orientations can offer thermally indoor conditions besides physical and psychological comfort in any settlement at lesser energy demand. This investigation uses a vast number of computer simulations to visualize and make better decisions about heating and cooling requirements of a building and facades as a function of window orientation in composite climatic condition of Lahore. This study in particular evaluates the solar load in residential buildings responsive to the objective of sustainable new housing leading to thoughtful integration of architecture. The orientation of the buildings could then be essentially integrated to the current architectural and urban design practices in order to optimize the relationship between the given site ant the orientations for sustainable developments.

  13. MOISTURE-BUFFERING CHARACTERISTICS OF BUILDING MATERIALS

    Directory of Open Access Journals (Sweden)

    Young Cheol Choi

    2016-05-01

    Full Text Available The humidity level of indoor air is an important factor influencing the air quality and energy consumption of buildings, as well as the durability of building components. Indoor humidity levels depend on several factors, such as moisture sources, air flow, and the adsorption/desorption properties of materials. The moisture-buffering characteristics of building materials that are in contact with indoor air may help moderate the variations of indoor humidity, especially in the summer and winter. In this study, the moisture adsorption/desorption properties of building materials were investigated experimentally and numerically. These properties can be used to characterize the ability of building materials to exchange moisture with the indoor environment. This study indicates that a building material surface resistivity was the main factor creating variations of moisture buffering.

  14. Tight or sick building syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Thirumalaikolundusubramanian, P; Shanmuganadan, S [Madurai Kamaraj Univ. (India). Dept. of Geography; Uma, A [Madurai Medical Coll. (India). Dept. of Medicine and Microbiology

    1991-01-01

    Modern buildings are designed with the usual heating, air-conditioning and ventilation equipment. In most of these buildings, air is continuously recirculated and, as a result, workers suffer from tight or sick building syndrome. This syndrome is discussed with reference to symptoms of air contamination, ventilation system standards and research needs. The most common symptoms of tight building syndrome are eye, nose and throat irritation, headache, fatigue, sneezing, difficulty in wearing contact lenses, chest tightness, nausea, dizziness and dermatitis. Symptoms experienced by 50 doctors and 50 paramedical personnel working in an air-conditioned intensive care unit and operating theatres of the Government Rajaji Hospital, Madurai in India were studied by means of a questionnaire survey. In the present study, respiratory and ocular symptoms were observed more in those working in operating theatres and were believed to be due to excessive use of formaldehyde used for sterilization. Various suggestions were made to prevent sick building syndrome. Moreover, the physicians treating sick individuals should be aware of the symptoms caused by indoor air pollutants as sufferers invariably require a change of environment rather than drugs. (orig.).

  15. Assigning Robust Default Values in Building Performance Simulation Software for Improved Decision-Making in the Initial Stages of Building Design.

    Science.gov (United States)

    Hiyama, Kyosuke

    2015-01-01

    Applying data mining techniques on a database of BIM models could provide valuable insights in key design patterns implicitly present in these BIM models. The architectural designer would then be able to use previous data from existing building projects as default values in building performance simulation software for the early phases of building design. The author has proposed the method to minimize the magnitude of the variation in these default values in subsequent design stages. This approach maintains the accuracy of the simulation results in the initial stages of building design. In this study, a more convincing argument is presented to demonstrate the significance of the new method. The variation in the ideal default values for different building design conditions is assessed first. Next, the influence of each condition on these variations is investigated. The space depth is found to have a large impact on the ideal default value of the window to wall ratio. In addition, the presence or absence of lighting control and natural ventilation has a significant influence on the ideal default value. These effects can be used to identify the types of building conditions that should be considered to determine the ideal default values.

  16. CAPACITY BUILDING OF TEACHERS THROUGH DISTANCE MODE USING TELECONFERENCEING AS AN INNOVATIVE TOOL

    Directory of Open Access Journals (Sweden)

    Manas RANJAN PANIGRAHI

    2012-04-01

    Full Text Available Sarva Shiksha Abhiyan (SSA is a national programme to the goals of Universalization of Elementary Education in India. Distance Education Programme (DEP plays a major role in providing technical support to the states in building capacity among institutions and people at national, state, district and sub-district levels to design, develop, produce and deliver distance learning inputs and materials in a recurrent manner. Rajasthan Council of Primary Education, Jaipur and DEP-SSA, IGNOU, New Delhi has organized 07 content based teleconferences during the period January, 2005 to October, 2005 for the capacity building of elementary school teachers. The main Objective of the study was to find out the effectiveness of the capacity building of teachers through distance mode using teleconferencing as an innovative tool. Method: the researcher was used survey method under descriptive research for investigating the impact of teleconference programmes organized on different topics and areas. Sample: The sample consists of 4775 elementary school teachers as participants from the different learning ends of the Rajasthan were selected for the study. Tools: The DEP-SSA, IGNOU developed structured opinionnaire/feedback format to know the effectiveness of teleconference programme. Data analysis: The collected data were tabulated and analyzed with the percentage techniques and it is presented in table. Finding: Most of the teacher respondents agreed on the positive contribution of teleconferencing towards capacity building of teachers.

  17. Impact of risk analysis on ITER nuclear buildings layout

    International Nuclear Information System (INIS)

    Sabathe, Laurent; Lignini, Franck; Rodriguez-Rodrigo, Lina; Uzan-Elbez, Joelle; Girard, Jean-Philippe

    2007-01-01

    The internal layout of ITER nuclear buildings (Tokamak, Tritium, Hot cell and Radwaste buildings) is the result of an iterative process. Notwithstanding civil engineering requirements, technical and functional requirements for the processes housed in the buildings, the internal layout must also take into account safety requirements and workers protection requirements in normal, incidental and accidental conditions. Potential hazards and constraints result in the definition of various zonings. Each room is classified depending on the level of the risks induced by normal and incidental or accidental conditions: - radiological exposure to tritium, and activated products → radiological zoning; - exposure to beryllium (vacuum vessel blankets) → beryllium zoning; - exposure to electromagnetic fields during plasma shots → electromagnetic zoning; - fire hazard: fire compartmentalization; ·explosion hazard: anti-blast zoning; - waste treatment → waste zoning. Prevention of common mode failure due to internal hazards (fire, flooding, load drop...) for redundant safety important components is also taken into account by geographical separation or by installation of protections between components (either in the same room or preferably when possible by segregation in different rooms). The designer has also taken into account access requirements to equipments and circulation rules for personal, material and substances in ITER nuclear buildings. Risk analyses are performed in the Preliminary Safety Report in order to demonstrate that the layout of ITER nuclear buildings allows meeting the safety objectives and takes into account the requirements associated with the zonings classifications and complies with the regulation. When necessary, modifications are implemented in the design. For example, recent layout modifications are been studied in the tritium building: utility rooms (electrical supply) were transferred outside the radiological hazard zones. A direct access from

  18. A study of the passive cooling potential in simulated building in Latvian climate conditions

    Science.gov (United States)

    Prozuments, A.; Vanags, I.; Borodinecs, A.; Millers, R.; Tumanova, K.

    2017-10-01

    In this paper authors point out that overheating in buildings during summer season is a major problem in moderate and cold climates, not only in warm climate zones. Mostly caused by solar heat gains, especially in buildings with large glazed areas overheating is a common problem in recently constructed low-energy buildings. At the same time, comfort demands are increasing. While heating loads can be decreased by improving the insulation of the building envelope, cooling loads are also affecting total energy demand. Passive cooling solutions allow reduction of heat gains, and thus reducing the cooling loads. There is a significant night cooling potential with low temperatures at night during summer in moderate and cold climates. Night cooling is based on cooling of buildings thermal mass during the night and heat accumulation during the day. This approach allows to provide thermal comfort, reducing cooling loads during the day. Authors investigate thermal comfort requirements and causes for discomfort. Passive cooling methods are described. The simulation modeling is carried out to analyze impact of constructions and building orientation on energy consumption for cooling using the IDA-ICE software. Main criteria for simulation analysis are energy consumption for cooling and thermal comfort.

  19. 77 FR 28623 - Comment Request for Information Collection for the Impact Evaluation of the YouthBuild Program...

    Science.gov (United States)

    2012-05-15

    ..., earnings, and job characteristics? What are YouthBuild's impacts on crime and delinquency? What are the... Collection for the Impact Evaluation of the YouthBuild Program; New Collection AGENCY: Employment and... instruments are clearly understood, and the impact of collection requirements on respondents can be properly...

  20. Energy audit role in building planning

    Science.gov (United States)

    Sipahutar, Riman; Bizzy, Irwin

    2017-11-01

    An energy audit is one way to overcome the excessive use of energy in buildings. The increasing growth of population, economy, and industry will have an impact on energy demand and the formation of greenhouse gas emissions. Indonesian National Standard (SNI) concerning the building has not been implemented optimally due to the socialization process by a government not yet been conducted. An energy audit of buildings has been carried out at offices and public services. Most electrical energy in buildings used for air refresher equipment or air conditioning. Calculation of OTTV has demonstrated the importance of performing since the beginning of the planning of a building to get energy-efficient buildings.

  1. Energy - efficient buildings in pakistan

    International Nuclear Information System (INIS)

    Sohail, M.; Qureshi, M.U.D.

    2011-01-01

    Pakistan is one of the countries with the highest energy consumption for domestic use. Annual energy consumption by the domestic sector is 45.9 % of the total, while the industrial sector, consumes about 27.5%. About half of the total energy consumed is used in buildings and/or heating, ventilation and air-conditioning (HVAC) and lighting appliances. The energy consumed for the same purposes in China and UK is 25 to 30 % and 40 %, respectively, even in extreme weather conditions. Energy deficiency in Pakistan is approximately 5,000 MWe, which results in worst load-shedding in summers and, lately, even in winters. Building new energy sources like dams, coal power plants and renewable energy power projects are some possible solutions, but these are time taking and need at least 2 to 6 years to complete, depending upon the nature of the project. Fast development of energy-efficient buildings is, therefore, necessary to deal with exacerbating energy-crisis and related environmental impact in Pakistan. Innovations in the prevailing building-design will help the country in reducing the energy burden. These innovations may include improved architectural designs, energy-efficient building materials, electrical appliances and implementation of building energy-efficiency codes. In 1987, the National Energy Conservation Centre (ENERCON), was established under Ministry of Environment, Government of Pakistan, with the aim to build awareness among the masses for energy conservation, and to make policies regarding energy-conservation structures in the country. But no policy regarding building energy codes has been introduced by ENERCON till now. In collaboration with Pakistan Engineering Council (PEC), ENERCON has recently finalized the Building Energy Code of Pakistan Energy Provisions 2011 for which statutory notification is under process for necessary amendment in the building by-laws. The implementation of this Energy Code will result in 25 to 30 % of energy savings in the

  2. Potential for energy technologies in residential and commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Glesk, M.M.

    1979-11-01

    The residential-commercial energy technology model was developed as a planning tool for policy analysis in the residential and commercial building sectors. The model and its procedures represent a detailed approach to estimating the future acceptance of energy-using technologies both in new construction and for retrofit into existing buildings. The model organizes into an analytical framework all relevant information and data on building energy technology, building markets, and government policy, and it allows for easy identification of the relative importance of key assumptions. The outputs include estimates of the degree of penetration of the various building energy technologies, the levels of energy use savings associated with them, and their costs - both private and government. The model was designed to estimate the annual energy savings associated with new technologies compared with continued use of conventional technology at 1975 levels. The amount of energy used under 1975 technology conditions is referred to as the reference case energy use. For analytical purposes the technologies were consolidated into ten groupings: electric and gas heat pumps; conservation categories I, II, and III; solar thermal (hot water, heating, and cooling); photovoltaics, and wind systems. These groupings clearly do not allow an assessment of the potential for individual technologies, but they do allow a reasonable comparison of their roles in the R/C sector. Assumptions were made regarding the technical and economic performances of the technologies over the period of the analysis. In addition, the study assessed the non-financial characteristics of the technologies - aesthetics, maintenance complexity, reliability, etc. - that will also influence their market acceptability.

  3. Impact of building forms on thermal performance and thermal comfort conditions in religious buildings in hot climates: a case study in Sharjah city

    Science.gov (United States)

    Mushtaha, Emad; Helmy, Omar

    2017-11-01

    The common system used for thermal regulation in mosques of United Arab Emirates (UAE) is the heating, ventilating and air-conditioning (HVAC) system. This system increases demands on energy consumption and increases CO2 emission. A passive design approach is one of the measures to reduce these problems. This study involved an analytical examination of building forms, followed by testing the impact of these forms on its thermal performance and indoor thermal comfort. The tests were conducted using energy simulations software packages. Passive parameters such as shading devices, thermal insulation and natural ventilation were applied in six cases, including the baseline case within each form. The obtained results showed a significant effect of mosque forms as well as passive design techniques on the thermal comfort within the structures. The findings confirmed that the use of passive design alone would not help achieve thermal comfort, but reduce the annual energy consumption by10%. By integrating a hybrid air-conditioning system as another supporting approach, the annual energy consumption could be reduced by 67.5%, which allows for the designing of a much smaller HVAC system.

  4. Radon and the seal offered by the building shell

    International Nuclear Information System (INIS)

    Crameri, R.; Furrer, D.; Burkart, W.

    1992-01-01

    Long term measurements of the radon level before and after the building shell is sealed were carried out in 25 apartment buildings and 7 houses. The average values of the most important meteorological parameters of wind speed, external temperature and barometric pressure which may influence the radon level, were absolutely comparable during the measurement periods before and after the energy renovation of the buildings. Both in houses and in apartment buildings the radon level remained practically unchanged after the building shell was sealed. The lack of any increase in the radon level after reducing the air exchange rate can be explained by virtue of the fact that the balance between the infiltration and elimination of the radon before and after the energy renovation of the buildings remained unchanged. In addition to reducing the air exchange rate, sealing the building shell therefore also results in a reduction in radon infiltration from the soil. Although it is possible in certain cases for the radon level to increase after the building shell has been sealed, a general increase in radon levels inside living areas as a result of energy renovation work can be dismissed. 2 figs., 3 tabs., 30 refs

  5. Descent in buildings (AM-190)

    CERN Document Server

    Mühlherr, Bernhard; Weiss, Richard M

    2015-01-01

    Descent in Buildings begins with the resolution of a major open question about the local structure of Bruhat-Tits buildings. The authors then put their algebraic solution into a geometric context by developing a general fixed point theory for groups acting on buildings of arbitrary type, giving necessary and sufficient conditions for the residues fixed by a group to form a kind of subbuilding or "form" of the original building. At the center of this theory is the notion of a Tits index, a combinatorial version of the notion of an index in the relative theory of algebraic groups. These results

  6. Influence of environmental conditions on production of volatiles by Trichoderma atroviride in relation with the sick building syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Polizzi, Viviana [Ghent University, Faculty of Bioscience Engineering, Department of Sustainable Organic Chemistry and Technology, Coupure links 653, B-9000 Ghent (Belgium); Ghent University, Faculty of Pharmaceutical Sciences, Laboratory of Food Analysis, Harelbekestraat 72, B-9000 Ghent (Belgium); Adams, An; De Kimpe, Norbert [Ghent University, Faculty of Bioscience Engineering, Department of Sustainable Organic Chemistry and Technology, Coupure links 653, B-9000 Ghent (Belgium); Picco, Anna Maria [Pavia University, Faculty of Sciences, Department of Territorial Ecology and Environment, via S. Epifanio 14, 27100 Pavia (Italy); Adriaens, Els; Lenoir, Joke [Ghent University, Faculty of Pharmaceutical Sciences, Laboratory of Pharmaceutical Technology, Harelbekestraat 72, B-9000 Ghent (Belgium); Van Peteghem, Carlos; De Saeger, Sarah [Ghent University, Faculty of Pharmaceutical Sciences, Laboratory of Food Analysis, Harelbekestraat 72, B-9000 Ghent (Belgium)

    2011-04-15

    A Trichoderma atroviride strain was isolated from a water-damaged office and the production of microbial volatile organic compounds (MVOCs) was investigated by means of headspace solid phase microextraction GC-MS. Different growth conditions (substrate, temperature, relative humidity) were selected, resembling indoor parameters, to elucidate a possible relationship between MVOCs, produced by Trichoderma atroviride, and the Sick Building Syndrome. In general, the range of MVOCs and the emitted quantities were larger on malt extract agar (MEA) than on wallpaper and plasterboard. Particular attention was dedicated to the volatile marker 6-pentyl-2-pyrone, a compound produced in high quantities on MEA, and its mucosal irritation potency was shown in a slug mucosal irritation assay. Some compounds characteristic for growth on specific building materials were detected, e.g. 2-ethylcyclopentanone, menthone, iso-menthone and trans-p-menth-2-en-7-ol on plasterboard and 4-heptanone and 1-octen-3-ol on wallpaper. Relative humidity and substrate had a more important effect on MVOC production than temperature. (author)

  7. Multidisciplinary Energy Assessment of Tertiary Buildings: Automated Geomatic Inspection, Building Information Modeling Reconstruction and Building Performance Simulation

    Directory of Open Access Journals (Sweden)

    Faustino Patiño-Cambeiro

    2017-07-01

    Full Text Available There is an urgent need for energy efficiency in buildings within the European framework, considering its environmental implications, and Europe’s energy dependence. Furthermore, the need for enhancing and increasing productivity in the building industry turns new technologies and building energy performance simulation environments into extremely interesting solutions towards rigorous analysis and decision making in renovation within acceptable risk levels. The present work describes a multidisciplinary approach for the estimation of the energy performance of an educational building. The research involved data acquisition with advanced geomatic tools, the development of an optimized building information model, and energy assessment in Building Performance Simulation (BPS software. Interoperability issues were observed in the different steps of the process. The inspection and diagnostic phases were conducted in a timely, accurate manner thanks to automated data acquisition and subsequent analysis using Building Information Modeling based tools (BIM-based tools. Energy simulation was performed using Design Builder, and the results obtained were compared with those yielded by the official software tool established by Spanish regulations for energy certification. The discrepancies between the results of both programs have proven that the official software program is conservative in this sense. This may cause the depreciation of the assessed buildings.

  8. The new research centre of the Brazilian Petroleum Company in Rio de Janeiro, Brazil: The achievements in the thermal performance of air-conditioned buildings in the tropics

    Energy Technology Data Exchange (ETDEWEB)

    Brandao, Rafael; Marcondes, Monica Pereira; De Benedetto, Gisele S.; Goncalves, Joana Carla Soares; Duarte, Denise Helena Silva; Ramos, Jose Ovidio [Laboratorio de Conforto Ambiental e Eficiencia Energetica (LABAUT), Departamento de Tecnologia da Arquitetura (AUT), Faculdade de Arquitetura e Urbanismo, Universidade de Sao Paulo (FAUUSP), Sao Paulo, Brasil, Rua do Lago, 876, Cidade Universitaria, 05508-900 Sao Paulo, SP (Brazil)

    2008-07-01

    The study on the thermal performance of the air-conditioned buildings of the new research centre of the Brazilian Petroleum Company, in the tropical climate of Rio de Janeiro, was part of a bigger research and consultancy project involving environmental issues. The architectural design was the subject of a national competition in 2004, encompassing over 100,000 m{sup 2}. According to the design brief, out of the 10 buildings of the new research centre, 7 have to be either completely or partially air-conditioned, due to specific occupation requirements. The challenge for better thermal performance was related to systems' energy efficiency, to the introduction of natural ventilation and to the notion of adaptive comfort, which were verified with the support of thermal dynamic simulations. At the early stages of the assessments, the potential for natural ventilation in the working spaces considering the mixed-mode strategy achieved 30% of occupation hours. However, the development of the design project led to fully air-conditioned working spaces, due to users' references regarding the conventional culture of the office environment. Nevertheless, the overall architectural approach in accordance to the climatic conditions still showed a contribution to the buildings' energy efficiency. (author)

  9. Responding to changes in sea level: engineering implications

    National Research Council Canada - National Science Library

    National Research Council Staff; Marine Board; Commission on Engineering and Technical Systems; Division on Engineering and Physical Sciences; National Research Council

    1987-01-01

    ... Mean Sea Level Marine Board Commission on Engineering and Technical Systems National Research Council National Academy Press Washington, D.C. 1987 Copyrightthe cannot be not from book, paper however, version for formatting, original authoritative the typesetting-specific the as from created publication files XML from other this and of recom...

  10. Energy Efficiency Requirements in Building Codes, Energy Efficiency Policies for New Buildings. IEA Information Paper

    Energy Technology Data Exchange (ETDEWEB)

    Laustsen, Jens

    2008-03-15

    The aim of this paper is to describe and analyse current approaches to encourage energy efficiency in building codes for new buildings. Based on this analysis the paper enumerates policy recommendations for enhancing how energy efficiency is addressed in building codes and other policies for new buildings. This paper forms part of the IEA work for the G8 Gleneagles Plan of Action. These recommendations reflect the study of different policy options for increasing energy efficiency in new buildings and examination of other energy efficiency requirements in standards or building codes, such as energy efficiency requirements by major renovation or refurbishment. In many countries, energy efficiency of buildings falls under the jurisdiction of the federal states. Different standards cover different regions or climatic conditions and different types of buildings, such as residential or simple buildings, commercial buildings and more complicated high-rise buildings. There are many different building codes in the world and the intention of this paper is not to cover all codes on each level in all countries. Instead, the paper details different regions of the world and different ways of standards. In this paper we also evaluate good practices based on local traditions. This project does not seek to identify one best practice amongst the building codes and standards. Instead, different types of codes and different parts of the regulation have been illustrated together with examples on how they have been successfully addressed. To complement this discussion of efficiency standards, this study illustrates how energy efficiency can be improved through such initiatives as efficiency labelling or certification, very best practice buildings with extremely low- or no-energy consumption and other policies to raise buildings' energy efficiency beyond minimum requirements. When referring to the energy saving potentials for buildings, this study uses the analysis of recent IEA

  11. Challenges to Building Surveyors From The Perspectives Of Non Surveyors

    Directory of Open Access Journals (Sweden)

    Isnin Zarina

    2016-01-01

    Full Text Available Awareness on the importance of Building Surveyors in Malaysia is still low as the role and skills of this profession are not fully understood. Although studies indicated that Building Surveyors are still in demand, even without the Building Surveyor Act, many graduates are experiencing inadequate employment opportunities in the current economic situation. Little is known on the views from other stakeholders about BS. This research aims to examine the awareness and opinions on BS in Malaysia amongst construction stakeholders. Questionnaire surveys were collected from 120 respondents from construction, maintenance and insurance companies and interviews were conducted to selected built environment respondents. It was found that awareness and knowledge on BS are still low as they lack information on the profession and professional recognitions. Some views indicated on a major identity crisis for having fragmented and disparate range of modules. The cause may have resulted in problems on public recognition, poor understanding of the surveyor’s skills, and fewer job opportunities. Several suggested the profession to have a clear, coherent and relevant identity, with strong professional structures in order for the profession to survive and gain recognition from the government. Graduates are also recommended to acquire other skills and training in order for them to be significant to the construction industry.

  12. Assessment of gamma radiation exposure inside a newly constructed building and a proposed regulatory guideline for exposure control from natural radioactivity in future buildings

    International Nuclear Information System (INIS)

    Shukla, V.K.; Sadasivan, S.; Sundaram, V.K.; Nambi, K.S.V.

    1995-01-01

    Naturally occurring radionuclides in building materials are one of the sources of radiation exposure of the population. The various materials used for constructing a new building were assessed for 40 K, 232 Th and 238 U radioactivity and the external gamma dose rate inside the building was predicted by using the computer code QAD-CGGP. The external dose rate was also measured by a scintillation gamma monitor after the construction of the building. In the building studied, the floor and the ceilings are seen to contribute about 35% each of the total radiation dose inside the building from the natural radioactivity present in the construction materials and the underlying soil; the walls contributed about 15%. A sensitivity analysis assuming extreme conditions of radioactivity concentrations as are normally observed in the Indian context, indicates the possibility of indoor gamma radiation fields varying by two orders of magnitude. The possible control methodologies and recommendations are also discussed for keeping the population exposure as low as reasonable achievable. It is evaluated that radioactivity limits of 370 Bq.kg -1 of radium equivalent and 85 Bq.kg -1 of 226 Ra when applied concurrently, might limit the indoor exposure to reasonably accepted low levels of health risks. (author)

  13. A Low-energy Building under Arctic Conditions - Experiences After Five Years of Operation

    DEFF Research Database (Denmark)

    Rode, Carsten; Vladyková, Petra; Kotol, Martin

    2011-01-01

    In 2005, a low energy house was inaugurated in Sisimiut, Greenland. The house and the plans with it were presented at the third International Building Physics Conference in 2006. The house is characterised by having a highly insulated building envelope which is almost free of thermal bridges, adv...

  14. The main demands and criteria for building site choice for radioactive waste repositories

    International Nuclear Information System (INIS)

    Angelova, R.; Sandul, G.A.; Sen'ko, T.Ya.

    2002-01-01

    There are considered the main demands of building site choice for RAW repositories. At this the accent is placed on geological repositories (underground repositories of geological type) and near surface repositories assigned to disposal of low- and intermediate-level short- and mediate-lived radionuclides. These demands are conditionally separated into two blocks: account of social development of the adjoining territories; account of natural factors characterizing building site. Further there are discussed the questions of anthropogenous influence on a safety functioning of RAW repositories and of urgency of stable development of the adjoining territories. In context of the Ukrainian and other states nuclear laws there is also considered the lawful aspect defining the building site choice for RAW repositories

  15. REVITALIZING THE SUNAN KUDUS’ MULTICULTURALISM IN RESPONDING ISLAMIC RADICALISM IN INDONESIA

    Directory of Open Access Journals (Sweden)

    Nur Said

    2014-05-01

    Full Text Available This article’s main focus is on exploring Sunan Kudus’multiculturalism in Java with special focus on revitalizing them in responding Islamic radicalism in Indonesia. In this writing the authors use the semiotic and phenomenological approaches and supported by the oral history. Semiotics in this case can be a form of deconstruction of the understanding that was considered to be established. So it will be able to find the cultural capital with does not separate the spiritualism of Sunan Kudus. Some important conclusions are: First, the presence of Sunan Kudus in has brought the mission of Walisong to transmit a peaceful Islam in Java through a cultural approach, according to prominent local situation and conditions of each. Second, Sunan Kudus has built a successful political integration with the rights of democratic participation that considers tolerance and equality for citizens even though dealing with the different religious communities such as Hindu and Confucianism so that awakened a ‘social system’ with democratic civility, known as “Kudus Darussalam”. Third, the values and spirit of multiculturalism of Sunan Kudus are a cultural capital that will be the habitus of the community and strengthen democratic civility to the level of actions (behaviors, when reconstructed through a systematic educational values in responding the Islamic radicalism in the name of democracy. Keywords: Revitalizing, Sunan Kudus’ multiculturalism, Islamic radicalism

  16. Adipose gene expression prior to weight loss can differentiate and weakly predict dietary responders.

    Directory of Open Access Journals (Sweden)

    David M Mutch

    Full Text Available BACKGROUND: The ability to identify obese individuals who will successfully lose weight in response to dietary intervention will revolutionize disease management. Therefore, we asked whether it is possible to identify subjects who will lose weight during dietary intervention using only a single gene expression snapshot. METHODOLOGY/PRINCIPAL FINDINGS: The present study involved 54 female subjects from the Nutrient-Gene Interactions in Human Obesity-Implications for Dietary Guidelines (NUGENOB trial to determine whether subcutaneous adipose tissue gene expression could be used to predict weight loss prior to the 10-week consumption of a low-fat hypocaloric diet. Using several statistical tests revealed that the gene expression profiles of responders (8-12 kgs weight loss could always be differentiated from non-responders (<4 kgs weight loss. We also assessed whether this differentiation was sufficient for prediction. Using a bottom-up (i.e. black-box approach, standard class prediction algorithms were able to predict dietary responders with up to 61.1%+/-8.1% accuracy. Using a top-down approach (i.e. using differentially expressed genes to build a classifier improved prediction accuracy to 80.9%+/-2.2%. CONCLUSION: Adipose gene expression profiling prior to the consumption of a low-fat diet is able to differentiate responders from non-responders as well as serve as a weak predictor of subjects destined to lose weight. While the degree of prediction accuracy currently achieved with a gene expression snapshot is perhaps insufficient for clinical use, this work reveals that the comprehensive molecular signature of adipose tissue paves the way for the future of personalized nutrition.

  17. Overview of treatment and conditioning of low-level wastes

    International Nuclear Information System (INIS)

    Trevorrow, L.

    1986-01-01

    The consideration of alternative technologies in low-level waste management is assumed to be partly a response to current demands for lower risk in waste disposal. One of the determinants of risk in waste disposal is the set of characteristics of the materials placed into disposal cells, i.e., the products of treatment and conditioning operations. The treatment and conditioning operations that have been applied to waste streams are briefly examined. Three operations are the most important determinants of the stability that will contribute to reducing risk at the disposal cell: compaction, high-integrity containers, and solidification. The status of these three operations is reviewed

  18. Maintenance Planning for Historic Buildings

    Directory of Open Access Journals (Sweden)

    Diana Plian

    2008-01-01

    Full Text Available The key to good maintenance of historic buildings is a long-range maintenance plan. Long-range planning recognizes a responsibility to the future to prolong the useful life of a building by preserving it in its present condition and preventing or slowing deterioration and damage from natural or other causes.

  19. INL High Performance Building Strategy

    Energy Technology Data Exchange (ETDEWEB)

    Jennifer D. Morton

    2010-02-01

    (LEED®) Green Building Rating System (LEED 2009). The document employs a two-level approach for high performance building at INL. The first level identifies the requirements of the Guiding Principles for Sustainable New Construction and Major Renovations, and the second level recommends which credits should be met when LEED Gold certification is required.

  20. Self-energy production applied to buildings

    Energy Technology Data Exchange (ETDEWEB)

    Carlo, Fabricio Ramos del; Balestieri, Jose Antonio Perrella [Sao Paulo State University Julio de Mesquita Filho (UNESP), Guaratingueta, SP (Brazil)], E-mail: perrella@feg.unesp.br; Holanda, Marcelo Rodrigues de [Sao Paulo Univ. (EEL/USP), Lorena, SP (Brazil). Engineering School], E-mail: marcelo@debas.eel.usp.br

    2010-07-01

    The decentralization of energy production in order to obtain better environmental conditions, reducing greenhouse gas emissions and the cost reduction of electricity and thermal energy consumed in residential buildings has been proposed in the literature. This paper proposes to demonstrate what are the chances of having a microcogeneration system toward the residential application. In this study, we contemplate the technologies involved and their possible inputs that are arranged in a superstructure to be studied. As a first step we obtain the cost of the products generated by the configuration that consists basically of two sources of power generation, and through optimization calculations intended to obtain the best configuration, taking into consideration the selection between four fuels, two equipment generators (Fuel Cell and Internal Combustion Engine)and three levels of energy production for each one. An economic analysis is also presented to evaluate the opportunity of selling the energy generated considering the fluctuations of the residential building consumption needs. (author)