WorldWideScience

Sample records for resonance imaging arthrography

  1. Arthrography

    Medline Plus

    Full Text Available ... joint. Arthrography may use computed tomography (CT) scanning, magnetic resonance imaging (MRI) or fluoroscopy – a form of real- ... methods of direct arthrography examinations may also use magnetic resonance imaging (MRI) or computed tomography (CT) following contrast ...

  2. Evaluation of TFC tears with magnetic resonance imaging; Comparison with arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Kushida, Manabu; Imamura, Koutaro; Sumi, Mitsuhiro; Uetani, Masataka (Nagasaki Univ. (Japan). School of Medicine); Nagatani, Yoshifumi

    1993-09-01

    This study evaluated the accuracy of magnetic resonance imaging (MRI) in the detection of tears of the trianglar fibrocartilage (TFC). Eighteen patients with chronic pain in the ulnar side of their wrist were examined by MRI and arthrography. Compared with arthrography, MRI was effective in the evaluation of TFC tears with a sensitivity of 92%, a specificity of 67%, and an accuracy of 83%. (author).

  3. Arthrography

    Medline Plus

    Full Text Available ... may be used to guide the procedure. Alternate methods of direct arthrography examinations may also use magnetic resonance imaging (MRI) or computed tomography (CT) following ...

  4. Arthrography

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Direct Arthrography Arthrography is a type of medical imaging ... are the limitations of Direct Arthrography? What is Direct Arthrography? Arthrography is medical imaging to evaluate conditions ...

  5. Arthrography

    Medline Plus

    Full Text Available ... Z Direct Arthrography Arthrography is a type of medical imaging used to help evaluate and diagnose joint conditions ... Direct Arthrography? What is Direct Arthrography? Arthrography is medical imaging to evaluate conditions of joints. It can either ...

  6. Optimization of T2-weighted imaging for shoulder magnetic resonance arthrography by synthetic magnetic resonance imaging.

    Science.gov (United States)

    Lee, Seung Hyun; Lee, Young Han; Hahn, Seok; Yang, Jaemoon; Song, Ho-Taek; Suh, Jin-Suck

    2017-01-01

    Background Synthetic magnetic resonance imaging (MRI) allows reformatting of various synthetic images by adjustment of scanning parameters such as repetition time (TR) and echo time (TE). Optimized MR images can be reformatted from T1, T2, and proton density (PD) values to achieve maximum tissue contrast between joint fluid and adjacent soft tissue. Purpose To demonstrate the method for optimization of TR and TE by synthetic MRI and to validate the optimized images by comparison with conventional shoulder MR arthrography (MRA) images. Material and Methods Thirty-seven shoulder MRA images acquired by synthetic MRI were retrospectively evaluated for PD, T1, and T2 values at the joint fluid and glenoid labrum. Differences in signal intensity between the fluid and labrum were observed between TR of 500-6000 ms and TE of 80-300 ms in T2-weighted (T2W) images. Conventional T2W and synthetic images were analyzed for diagnostic agreement of supraspinatus tendon abnormalities (kappa statistics) and image quality scores (one-way analysis of variance with post-hoc analysis). Results Optimized mean values of TR and TE were 2724.7 ± 1634.7 and 80.1 ± 0.4, respectively. Diagnostic agreement for supraspinatus tendon abnormalities between conventional and synthetic MR images was excellent (κ = 0.882). The mean image quality score of the joint space in optimized synthetic images was significantly higher compared with those in conventional and synthetic images (2.861 ± 0.351 vs. 2.556 ± 0.607 vs. 2.750 ± 0.439; P optimized TR and TE for shoulder MRA enables optimization of soft-tissue contrast.

  7. Arthrography

    Medline Plus

    Full Text Available ... injected into the joint. Arthrography may use computed tomography (CT) scanning, magnetic resonance imaging (MRI) or fluoroscopy – ... also use magnetic resonance imaging (MRI) or computed tomography (CT) following contrast material injection into the joint. ...

  8. Arthrography

    Medline Plus

    Full Text Available ... injected into the joint. Arthrography may use computed tomography (CT) scanning, magnetic resonance imaging (MRI) or fluoroscopy – a ... also use magnetic resonance imaging (MRI) or computed tomography (CT) following contrast material injection into the joint. An ...

  9. Discrepancy between fluoroscopic arthrography and magnetic resonance arthrography in patients with arthroscopically confirmed supraspinatus tendon tears: The additional benefit of cine fluoroscopic arthrography images

    International Nuclear Information System (INIS)

    Hahn, Seok; Lee, Young Han; Suh, Jin Suck

    2016-01-01

    To determine the additional diagnostic benefits of fluoroscopic arthrography (FA) in patients with full-thickness supraspinatus tendon (SST) tears by comparing FA images with magnetic resonance arthrography (MRA) images. This study included FA and MRA images of 53 patients who were confirmed to have full-thickness SST tears by arthroscopy. In the FA analysis, the presence of contrast leakage into the subacromial-subdeltoid bursa was recorded. In the MRA analysis, contrast leakage, retraction of a torn tendon, width and length of the tear, and supraspinatus atrophy were evaluated. Patients were divided into the concordant group or the discordant group based on the presence of contrast leakage to compare the characteristics of SST tears. We used Fisher's exact test and two-sample t-test for the comparison. Of the 53 patients, 34 were included in the concordant group and 19 were included in the discordant group. In the concordant group, the grades of retraction were higher than those in the discordant group; the width and length of the tears were larger. Muscle atrophy was more severe in the concordant group. A full-thickness SST tear did not always exhibit contrast leakage on FA, particularly small SST tears or tears with low-grade retraction. FA can provide diagnostic information regarding the severity of full-thickness SST tears by itself

  10. Discrepancy between fluoroscopic arthrography and magnetic resonance arthrography in patients with arthroscopically confirmed supraspinatus tendon tears: The additional benefit of cine fluoroscopic arthrography images

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, Seok; Lee, Young Han; Suh, Jin Suck [Dept. Radiology, Research Institute of Radiological Science, Medical Convergence Research Institute, and Severance Biomedical Science Institute, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2016-12-15

    To determine the additional diagnostic benefits of fluoroscopic arthrography (FA) in patients with full-thickness supraspinatus tendon (SST) tears by comparing FA images with magnetic resonance arthrography (MRA) images. This study included FA and MRA images of 53 patients who were confirmed to have full-thickness SST tears by arthroscopy. In the FA analysis, the presence of contrast leakage into the subacromial-subdeltoid bursa was recorded. In the MRA analysis, contrast leakage, retraction of a torn tendon, width and length of the tear, and supraspinatus atrophy were evaluated. Patients were divided into the concordant group or the discordant group based on the presence of contrast leakage to compare the characteristics of SST tears. We used Fisher's exact test and two-sample t-test for the comparison. Of the 53 patients, 34 were included in the concordant group and 19 were included in the discordant group. In the concordant group, the grades of retraction were higher than those in the discordant group; the width and length of the tears were larger. Muscle atrophy was more severe in the concordant group. A full-thickness SST tear did not always exhibit contrast leakage on FA, particularly small SST tears or tears with low-grade retraction. FA can provide diagnostic information regarding the severity of full-thickness SST tears by itself.

  11. Preoperative conventional magnetic resonance images versus magnetic resonance arthrography of subacromial impingement syndrome

    International Nuclear Information System (INIS)

    Ahn, Sang Hyuk; Park, Jung Hwan; Moon, Tae Yong; Lee, In Sook; Lee, Seung Jun

    2012-01-01

    To evaluate the usefulness of conventional magnetic resonance images (MRI) for arthroscopic surgery in subacromial impingement syndrome of the shoulder, as an alternative to MR arthrography with additional T2 fat saturation images (MRA). The preoperative MRI of 77 patients (45 females, 32 males) (52 right, 25 left) and MRA of 34 patients (14 females, 20 males) (24 right, 10 left) with subsequent arthroscopic confirmation of subacromial impingement syndrome were reviewed retrospectively. The lesions requiring arthroscopic surgery were 95 subacromial spurs, 101 subacromial bursitis, and 51 full-thickness and 44 partial thickness tears of the supraspinatus among 111 cases for both studies. A two by two table was constructed in order to calculate the sensitivity and specificity of both studies against arthroscopic outcomes. Also we analyzed the false positive and false negative cases of the full-thickness tears individually. The detection rates of subacromial spur and bursitis and full and partial thickness tears of the supraspinatus were 91%, 94%, 77%, and 65% in MRI and 93%, 100%, 83%, and 77% in MRA respectively. Their specificities were 33%, 33%, 90%, and 76% in MRI and 50%, 75%, 100%, and 71% in MRA respectively. Eleven false negative cases in regards to MRI resulted in Ellman's grade 3 partial thickness tear (72.7%), mild bursitis (63.6%), greater tuberosity erosion (45.5%), and negative fluid signal of the glenohumeral joint (81.8%). Three false positive cases on the MRI were induced from errors with lower window depth and width on the imagings. Two false negative cases on MRA were induced from the adhesion between Ellman's grade 3 rim rent tear and the glenohumeral joint cavity. Conventional MR images could be used to decide the arthroscopic surgery in subacromial impingement syndrome, as an alternative to MR arthrography with additional T2 fat saturation images

  12. Preoperative conventional magnetic resonance images versus magnetic resonance arthrography of subacromial impingement syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Sang Hyuk; Park, Jung Hwan; Moon, Tae Yong [Pusan National Univ. Yangsan Hospital, Yangsan (Korea, Republic of); Lee, In Sook; Lee, Seung Jun [Pusan National Univ. Hospital, Busan (Korea, Republic of)

    2012-09-15

    To evaluate the usefulness of conventional magnetic resonance images (MRI) for arthroscopic surgery in subacromial impingement syndrome of the shoulder, as an alternative to MR arthrography with additional T2 fat saturation images (MRA). The preoperative MRI of 77 patients (45 females, 32 males) (52 right, 25 left) and MRA of 34 patients (14 females, 20 males) (24 right, 10 left) with subsequent arthroscopic confirmation of subacromial impingement syndrome were reviewed retrospectively. The lesions requiring arthroscopic surgery were 95 subacromial spurs, 101 subacromial bursitis, and 51 full-thickness and 44 partial thickness tears of the supraspinatus among 111 cases for both studies. A two by two table was constructed in order to calculate the sensitivity and specificity of both studies against arthroscopic outcomes. Also we analyzed the false positive and false negative cases of the full-thickness tears individually. The detection rates of subacromial spur and bursitis and full and partial thickness tears of the supraspinatus were 91%, 94%, 77%, and 65% in MRI and 93%, 100%, 83%, and 77% in MRA respectively. Their specificities were 33%, 33%, 90%, and 76% in MRI and 50%, 75%, 100%, and 71% in MRA respectively. Eleven false negative cases in regards to MRI resulted in Ellman's grade 3 partial thickness tear (72.7%), mild bursitis (63.6%), greater tuberosity erosion (45.5%), and negative fluid signal of the glenohumeral joint (81.8%). Three false positive cases on the MRI were induced from errors with lower window depth and width on the imagings. Two false negative cases on MRA were induced from the adhesion between Ellman's grade 3 rim rent tear and the glenohumeral joint cavity. Conventional MR images could be used to decide the arthroscopic surgery in subacromial impingement syndrome, as an alternative to MR arthrography with additional T2 fat saturation images.

  13. Arthrography

    Medline Plus

    Full Text Available ... guide the procedure. Alternate methods of direct arthrography examinations may also use magnetic resonance imaging (MRI) or ... the injection is typically monitored by fluoroscopy, the examination also commonly involves taking radiographs for documentation. These ...

  14. Arthrography

    Medline Plus

    Full Text Available ... risks? What are the limitations of Direct Arthrography? What is Direct Arthrography? Arthrography is medical imaging to ... a computer using x-rays. top of page What are some common uses of the procedure? Arthrographic ...

  15. Arthrography

    Medline Plus

    Full Text Available ... large film sheets (much like a large photographic negative). Today, most images are digital files that are ... limitations of arthrography? The limitations of arthrography include: Partial tears of the rotator cuff may not be ...

  16. Arthrography

    Medline Plus

    Full Text Available ... Z Direct Arthrography Arthrography is a type of medical imaging used to help evaluate and diagnose joint ... you are pregnant and discuss any recent illnesses, medical conditions, medications you’re taking, and allergies – especially ...

  17. Arthrography

    Medline Plus

    Full Text Available ... Your preparation may vary depending on which imaging method your exam will use. Tell your doctor if ... in assessing a joint abnormality. There are several methods to perform direct arthrography. Conventional direct arthrography of ...

  18. The diagnostic accuracy of acetabular labral tears using magnetic resonance imaging and magnetic resonance arthrography: a meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Toby O. [University of East Anglia, Faculty of Health, Queen' s Building, Norwich (United Kingdom); Hilton, Gemma [Norfolk and Norwich University Hospital, Norwich (United Kingdom); Toms, Andoni P.; Donell, Simon T. [Norfolk and Norwich University Hospital, University of East Anglia, Norwich (United Kingdom); Hing, Caroline B. [St. George' s Hospital, London (United Kingdom)

    2011-04-15

    Magnetic resonance imaging (MRI) and magnetic resonance arthrography (MRA) have been advocated for the diagnosis of acetabular labral tears. The purpose of this study was to determine the sensitivity and specificity of MRI and MRA in diagnosing acetabular labral tears using meta-analysis. Pertinent published and unpublished literature databases were reviewed. A two-by-two table was constructed to calculate the sensitivity and specificity of MRI or MRA investigations against surgical outcomes. Pooled sensitivity and specificity and Receiver Operating Characteristic curve (ROC) evaluations were performed. Methodological quality of each study was assessed using the QUADAS (Quality Assessment of Diagnostic Accuracy Studies) tool. Nineteen papers assessing 881 hips were reviewed. Conventional MRI was assessed in 13 studies and MRA was assessed in 16 studies. Whilst both MRI (0.5-3T) and MRA (0.5-3T) presented with a moderate sensitivity and specificity (sensitivity 66%, 87%; specificity 79%, 64%), diagnostic accuracy of MRA appeared to be superior to MRI in detecting acetabular labral tears on ROC curve interpretation. The literature poorly described population characteristics, assessor blinding, with limited sample sizes. MRI and MRA may be useful adjuncts in the diagnosis of acetabular labral tears in adults. MRA appears to be superior to conventional MRI. (orig.)

  19. Arthrography

    Medline Plus

    Full Text Available ... and possibly hear gurgling when the joint is moved. If your arthrography exam involves MR imaging: It is normal for the area of your body being imaged to feel slightly warm, but if it ...

  20. Arthrography

    Medline Plus

    Full Text Available ... medical imaging to evaluate conditions of joints. It can either be direct or indirect. Indirect arthrography is ... virtually all other internal body structures. The images can then be examined on a computer monitor connected ...

  1. Arthrography

    Medline Plus

    Full Text Available ... a table on which the patient lies. The traditional MRI unit is a large cylinder-shaped tube ... MRI) - Shoulder X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Direct Arthrography Videos ...

  2. Arthrography

    Medline Plus

    Full Text Available ... the joint and appears on the MR images. As in conventional direct arthrography, the contrast material outlines the structures within the joint, such as cartilage, ligaments and bones, and allows them to ...

  3. Arthrography

    Medline Plus

    Full Text Available ... conventional direct arthrography and may be supplemented by air to produce a double contrast CT arthrogram. CT ... tissue shows up in shades of gray and air appears black. Until recently, x-ray images were ...

  4. Arthrography

    Medline Plus

    Full Text Available ... thus allowing for enhanced imaging of small internal structures. This leads to improved evaluation of diseases or ... conventional direct arthrography, the contrast material outlines the structures within the joint, such as cartilage, ligaments and ...

  5. Magnetic resonance imaging and magnetic resonance arthrography of the shoulder: dependence on the level of training of the performing radiologist for diagnostic accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Theodoropoulos, John S. [University of Toronto, Division of Orthopaedics, Mount Sinai Hospital and the University Health Network, Toronto, ON (Canada); Andreisek, Gustav [University of Toronto, Department of Medical Imaging, Mount Sinai Hospital and the University Health Network, Toronto, ON (Canada); University Hospital Zuerich, Institute for Diagnostic Radiology, Zuerich (Switzerland); Harvey, Edward J. [McGill University, Division of Orthopaedics, MUHC - Montreal General Hospital, Montreal, Quebec (Canada); Wolin, Preston [Center for Athletic Medicine, Chicago, IL (United States)

    2010-07-15

    Discrepancies were identified between magnetic resonance (MR) imaging and clinical findings in patients who had MR imaging examinations evaluated by community-based general radiologists. The purpose of this study was to evaluate the diagnostic performance of MR imaging examinations of the shoulder with regard to the training level of the performing radiologist. A review of patient charts identified 238 patients (male/female, 175/63; mean age, 40.4 years) in whom 250 arthroscopies were performed and who underwent MR imaging or direct MR arthrography in either a community-based or hospital-based institution prior to surgery. All MR imaging and surgical reports were reviewed and the diagnostic performance for the detection of labral, rotator cuff, biceps, and Hill-Sachs lesions was determined. Kappa and Student's t test analyses were performed in a subset of cases in which initial community-based MR images were re-evaluated by hospital-based musculoskeletal radiologists, to determine the interobserver agreement and any differences in image interpretation. The diagnostic performance of community-based general radiologists was lower than that of hospital-based sub-specialized musculoskeletal radiologists. A sub-analysis of re-evaluated cases showed that musculoskeletal radiologists performed better. {kappa} values were 0.208, 0.396, 0.376, and 0.788 for labral, rotator cuff, biceps, and Hill-Sachs lesions (t test statistics: p =<0.001, 0.004, 0.019, and 0.235). Our results indicate that the diagnostic performance of MR imaging and MR arthrography of the shoulder depends on the training level of the performing radiologist, with sub-specialized musculoskeletal radiologists having a better diagnostic performance than general radiologists. (orig.)

  6. Arthrography

    Medline Plus

    Full Text Available ... The images can then be examined on a computer monitor connected to an image archive (PACS system) or printed or copied to CD. MRI does not use ionizing radiation (x-rays). CT direct arthrography uses the same type of ... by a computer using x-rays. top of page What are ...

  7. Arthrography

    Medline Plus

    Full Text Available ... processes the imaging information is located in a separate room from the scanner. Other equipment necessary for performing arthrography include a variety of needles, syringes and a water-soluble contrast material. top of page How does the procedure work? X-rays are a form of radiation like ...

  8. Arthrography

    Medline Plus

    Full Text Available ... have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures that those parts of a patient's body not being imaged receive minimal radiation exposure. top of page What are the limitations of arthrography? The limitations of ...

  9. Evaluation of the triangular fibrocartilage complex tears by arthrography and MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, Makoto; Shibata, Yasushi [Hokkaido Kin-i-kyou Central Hospital, Sapporo (Japan); Takahata, Naoji

    1995-08-01

    Arthroscopic or open surgical findings in 21 wrists with chronic ulnar painful lesion were compared both with arthrography and magnetic resonance (MR) imaging results to evaluate the accuracy of the two diagnostic procedures in the detection of triangular fibrocartilage complex (TFCC) lesions. Arthrography investigations were performed for the 20 wrists but one that had allergy for iodine and MR imagings were performed for the recent 12 wrists. Arthrography and magnetic resonance (MR) imaging were almost equally useful for the detection of the TFCC injury and their injury sites. (author).

  10. Evaluation of lesions of the internal ligaments of the wrist; conventional magnetic resonance imaging versus MR arthrography (MRA

    Directory of Open Access Journals (Sweden)

    Heba Ahmed Kamal

    2014-09-01

    Conclusion: MR arthrography is a potent additional tool facilitating the diagnosis of different pathologic entities affecting the major internal ligaments of the wrist joint and helps to reduce arthroscopic interventions.

  11. Magnetic resonance arthrography in chronic wrist pain

    International Nuclear Information System (INIS)

    Valeri, G.; Ferrara, C.; Carloni, S.

    1999-01-01

    The purpose of this paper is to investigate the clinical role of Magnetic Resonance Arthrography (MRA) of the wrist in subjects with chronic pain. Thirty-five patients complaining of wrist pain for more than 6 months were submitted to MRI an MRA. All patients received and intra-articular injection of 2-10 mL of a 10 mmol saline solution of Gd-DPTA. The overall diagnostic accuracy rates of MRI and MRA were 40% and 81% respectively, with sensitivity and specificity of 63% and 39% (MRI) and of 82% and 79% (MRA). The conclusion is that compared with MRI, MRA can be considered a useful tool for the visualization of interosseus carpal ligaments and of the triangular fibrocartilage complex. MRA also helps detect injuries in these structures [it

  12. Arthrography

    Medline Plus

    Full Text Available ... of the radiation while soft tissue, such as muscle, fat and organs, allow more of the x- ... of arthrography? The limitations of arthrography include: Partial tears of the rotator cuff may not be detected ...

  13. Arthrography

    Medline Plus

    Full Text Available ... bear denotes child-specific content. Related Articles and Media Magnetic Resonance Imaging (MRI) - Musculoskeletal Radiation Dose in X-Ray and CT Exams Contrast Materials Magnetic Resonance Imaging (MRI) - Shoulder X-ray, ...

  14. All-in-One Magnetic Resonance Arthrography of the Shoulder in a Vertically Open Magnetic Resonance Unit

    Energy Technology Data Exchange (ETDEWEB)

    Vandevenne, J.E.; Vanhoenacker, F.; Beaulieu, C.F.; Bergman, A.; Butts Pauly, K.; Dillingham, M.F.; Lang, P.K. (Dept. of Radiology, Univ. Hospital Antwerp, Edegem-Antwerp (Belgium))

    2008-10-15

    Background: Magnetic resonance (MR) arthrography frequently involves joint injection under imaging guidance followed by MR imaging in static positions. Purpose: To evaluate if MR arthrography of the shoulder joint can be performed in a comprehensive fashion combining the MR-guided injection procedure, static MR imaging, and dynamic motion MR imaging in a single test. Material and Methods: Twenty-three shoulder joints were injected with Gd-DTPA2- under MR guidance. Static MR imaging was performed and included a three-point Dixon method to achieve water-selective images. Dynamic motion MR imaging with and without applying pressure to the upper arm was used to evaluate glenohumeral joint instability. In 10 cases, surgical correlation was available. Results: The all-in-one MR arthrography technique was successful in all patients, and took an average time of 65 min. All but one glenohumeral injection procedure were performed with a single needle pass, and no complications were observed. Out of eight labrum tears seen with static MR imaging, seven were confirmed at surgery. In 10 cases, dynamic motion MR imaging correlated well with the surgeon's intraoperative evaluation for presence and direction of instability. Conclusion: MR arthrography of the shoulder joint using a vertically open magnet can be performed as a single comprehensive test, including the injection and the static and dynamic motion MR imaging. Good diagnostic accuracy for intraarticular lesions and glenohumeral instability was found in a small sample.

  15. Arthrography

    Medline Plus

    Full Text Available ... you! Do you have a personal story about radiology? Share your patient story here Images × Image Gallery ... Magnetic Resonance Imaging (MRI) - Shoulder X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to ...

  16. Arthrography

    Medline Plus

    Full Text Available ... preparation is necessary before direct arthrography. Food and fluid intake do not need to be restricted, unless ... a syringe to drain (or aspirate) the joint fluid, which may be sent to a laboratory for ...

  17. Arthrography

    Medline Plus

    Full Text Available ... felt to be inadequate in assessing a joint abnormality. There are several methods to perform direct arthrography. ... The procedure is most often used to identify abnormalities within the: shoulder elbow wrist hip knee ankle ...

  18. Arthrography

    Medline Plus

    Full Text Available ... others nearby harm. These items include: jewelry, watches, credit cards and hearing aids, all of which can ... top of page What are the benefits vs. risks? Benefits Direct arthrography is particularly effective for detecting ...

  19. Arthrography

    Medline Plus

    Full Text Available ... CT arthrography and have claustrophobia (fear of enclosed spaces) or anxiety, you may want to ask your ... and sometimes air are injected into the joint space while the radiologist observes with fluoroscopy or ultrasound. ...

  20. Arthrography

    Medline Plus

    Full Text Available ... have MR or CT arthrography and have claustrophobia (fear of enclosed spaces) or anxiety, you may want ... physician and technologist if they may be pregnant. Children younger than 13 may need to be sedated ...

  1. Arthrography

    Medline Plus

    Full Text Available ... top of page How should I prepare? No special preparation is necessary before direct arthrography. Food and fluid intake do not need to be restricted, unless a sedative will be ...

  2. Arthrography

    Medline Plus

    Full Text Available ... Videos related to Direct Arthrography Sponsored by Please note RadiologyInfo.org is not a medical facility. Please ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  3. Arthrography

    Medline Plus

    Full Text Available ... by the interpreting radiologist. Frequently, the differentiation of abnormal (diseased) tissue from normal tissues is better with ... Benefits Direct arthrography is particularly effective for detecting disease of the structures within the joints such as ...

  4. Arthrography

    Medline Plus

    Full Text Available ... No special preparation is necessary before direct arthrography. Food and fluid intake do not need to be ... to iodine or x-ray contrast material, drugs, food, or environmental agents. However, the contrast material used ...

  5. Arthrography

    Medline Plus

    Full Text Available ... of the body to a small dose of ionizing radiation to produce pictures of the inside of the ... or copied to CD. MRI does not use ionizing radiation (x-rays). CT direct arthrography uses the same ...

  6. Arthrography

    Medline Plus

    Full Text Available ... over time. top of page What are the benefits vs. risks? Benefits Direct arthrography is particularly effective for detecting disease ... cancer from excessive exposure to radiation. However, the benefit of an accurate diagnosis far outweighs the risk. ...

  7. Arthrography

    Medline Plus

    Full Text Available ... of the body to a small dose of ionizing radiation to produce pictures of the inside of ... or copied to CD. MRI does not use ionizing radiation (x-rays). CT direct arthrography uses the ...

  8. Arthrography

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Direct arthrography is particularly effective for detecting ... used for conventional x-rays and CT scanning. Risks Any procedure where the skin is penetrated carries ...

  9. Direct magnetic resonance arthrography of the canine elbow

    Directory of Open Access Journals (Sweden)

    Yauheni Zhalniarovich

    2017-01-01

    Full Text Available This study compares the effects of four dilutions of the gadolinium-containing contrast media (1:100; 1:400; 1:800; 1:1,200 administered to the elbow on the quality of magnetic resonance images. All the examined dilutions had a positive effect on image quality, and 1:800 was regarded as the optimal dilution of gadolinium for viewing the elbow because it imparted good contrast to the joint cavity without obliterating the contours of articular surfaces. Transverse, sagittal, and dorsal low-field magnetic resonance images were obtained in 24 canine cadaver front limbs. The musculus biceps brachii, m. triceps brachii, m. extensor carpi radialis, m. flexor carpi ulnaris, the articular surfaces, the medial coronoid process and the anconeal process of the ulna were well visualized by High Resolution Gradient Echo, XBONE T2 and Spin Echo T1 sequences in the sagittal plane. The biceps brachii, pronator teres, flexor carpi radialis, extensor digitorum communis, extensor carpi radialis, deltoid muscle and the articular surface of the medial condyle of the humerus were very well visualized by 3D SST1 and XBONE T2 sequences in the transverse plane. The triceps brachii muscle, extensor digitorum lateralis muscle, superficial digital flexor, deep digital flexor and the medial condyle of the humerus were very well visualized by the Spin Echo T1 sequence in the dorsal plane. This article describes for the first time the use of the gadolinium contrast agent administered to the canine elbow joint during magnetic resonance modality. Magnetic resonance arthrography can be a helpful visualization technique in treating canine soft tissue elbow injury.

  10. T2[sup *] weighted MR imaging for the diagnosis of the perforation of triangular fibrocartilage; Comparison with arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Taro; Nakamura, Eiziro; Ahsoh, Kuniichi; Masumi, Shogo (Oita Medical Univ., Takatsuki (Japan))

    1994-05-01

    Perforation of the triangular fibrocartilage (TFC) has been considered an important factor in the etiology of pain in the ulnar wrist joint, and arthrography has been used conventionally to diagnose the perforation. Recently, magnetic resonance imaging (MRI) has been used to diagnose TFC perforation. Gundy et al. examined cadaver wrists with Tl weighted imaging and arthrography, and obtained findings suggesting that arthrography provides a more accurate diagnosis of the TFC perforation. To our knowledge, no comparison has yet been made between T2[sup *] weighted imaging and arthrography in the diagnosis of TFC perforation. The present study compared the usefulness of T2[sup *]-weighted imaging and arthrography in the diagnosis of TFC perforation in 22 wrist joints of 11 cadavers (5 males and 6 females with ages ranging from 61 to 92 years and an average age of 78.8 years) fixed in 60% formalin. The specimens were firstly analyzed by a T2[sup *]-weighted 0.5T MRI scan and subsequently by arthrography. After diagnosing the image obtained by the two methods, the accuracy of the diagnosis was determined by comparison with the macroscopic findings of autopsy, including the presence and degree of TFC perforation. A T2[sup *]-weighted MRI scan of the TFC perforation showed high-intensity areas over the distal radio-ulnar joint, and demonstrated the same diagnostic accuracy as arthrography, providing correct diagnoses in all cases other than linear perforation. However, neither of the image diagnostic methods allowed definition of the type of perforation. (author).

  11. Arthrography

    Medline Plus

    Full Text Available ... ankle arthrogram. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Magnetic Resonance Imaging (MRI) - ...

  12. Tears of the Supraspinatus Tendon: Assessment with Indirect Magnetic Resonance Arthrography in 67 Patients with Arthroscopic Correlation

    International Nuclear Information System (INIS)

    Dyck, P. van; Gielen, J.L.; Parizel, P.M.

    2009-01-01

    Background: Magnetic resonance (MR) arthrography is generally regarded as the gold standard for shoulder imaging. As an alternative to direct MR arthrography, the less invasive indirect MR arthrography technique was proposed, offering logistic advantages because fluoroscopic or ultrasonographic guidance for joint injection is not required. Purpose: To assess the diagnostic performance of indirect MR arthrography in the diagnosis of full- and partial-thickness supraspinatus tears in a symptomatic population. Material and Methods: Two radiologists with different levels of experience independently and retrospectively interpreted indirect MR (1.5T) arthrograms of the shoulder obtained in 67 symptomatic patients who underwent subsequent arthroscopy. On MR, the supraspinatus tendon was evaluated for full- or partial-thickness tear. With arthroscopy as the standard of reference, sensitivity, specificity, and diagnostic accuracy of indirect MR arthrography in the detection of full- and partial-thickness tears of the supraspinatus tendon was calculated. Kappa (κ) statistics were used for the assessment of the agreement between arthroscopic and imaging findings and for the assessment of interobserver agreement. Results: For full-thickness tears of the supraspinatus tendon, sensitivities, specificities, and accuracies exceeded 90% for both observers, with excellent interobserver agreement (κ = 0.910). For partial-thickness tears, sensitivities (38-50%) and accuracies (76-78%) were poor for both reviewers, and interobserver agreement was moderate (κ = 0.491). Discrepancies between MR diagnosis and arthroscopy were predominantly observed with small partial-thickness tears. Conclusion: Indirect MR arthrography is highly accurate in the diagnosis of full-thickness rotator cuff tears. However, the diagnosis of partial-thickness tears with indirect MR arthrography remains faulty, because exact demarcation of degenerative change and partial rupture is difficult. On the basis of

  13. Tears of the Supraspinatus Tendon: Assessment with Indirect Magnetic Resonance Arthrography in 67 Patients with Arthroscopic Correlation

    Energy Technology Data Exchange (ETDEWEB)

    Dyck, P. van; Gielen, J.L.; Parizel, P.M. (Dept. of Radiology, Univ. Hospital Antwerp and Univ. of Antwerp, Antwerp (Belgium)) (and others)

    2009-11-15

    Background: Magnetic resonance (MR) arthrography is generally regarded as the gold standard for shoulder imaging. As an alternative to direct MR arthrography, the less invasive indirect MR arthrography technique was proposed, offering logistic advantages because fluoroscopic or ultrasonographic guidance for joint injection is not required. Purpose: To assess the diagnostic performance of indirect MR arthrography in the diagnosis of full- and partial-thickness supraspinatus tears in a symptomatic population. Material and Methods: Two radiologists with different levels of experience independently and retrospectively interpreted indirect MR (1.5T) arthrograms of the shoulder obtained in 67 symptomatic patients who underwent subsequent arthroscopy. On MR, the supraspinatus tendon was evaluated for full- or partial-thickness tear. With arthroscopy as the standard of reference, sensitivity, specificity, and diagnostic accuracy of indirect MR arthrography in the detection of full- and partial-thickness tears of the supraspinatus tendon was calculated. Kappa (kappa) statistics were used for the assessment of the agreement between arthroscopic and imaging findings and for the assessment of interobserver agreement. Results: For full-thickness tears of the supraspinatus tendon, sensitivities, specificities, and accuracies exceeded 90% for both observers, with excellent interobserver agreement (kappa = 0.910). For partial-thickness tears, sensitivities (38-50%) and accuracies (76-78%) were poor for both reviewers, and interobserver agreement was moderate (kappa = 0.491). Discrepancies between MR diagnosis and arthroscopy were predominantly observed with small partial-thickness tears. Conclusion: Indirect MR arthrography is highly accurate in the diagnosis of full-thickness rotator cuff tears. However, the diagnosis of partial-thickness tears with indirect MR arthrography remains faulty, because exact demarcation of degenerative change and partial rupture is difficult. On the

  14. Arthrography

    Medline Plus

    Full Text Available ... your procedure. top of page What does the equipment look like? The equipment typically used for this examination consists of a ... in a separate room from the scanner. Other equipment necessary for performing arthrography include a variety of ...

  15. Arthrography

    Medline Plus

    Full Text Available ... may help your physician determine the cause of chronic joint pain and what therapies may be effective. ... Benefits Direct arthrography is particularly effective for detecting disease ... Any procedure where the skin is penetrated carries a risk of infection. The ...

  16. Arthrography

    Medline Plus

    Full Text Available ... to Direct Arthrography Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ... links: For the convenience of our users, RadiologyInfo .org provides links to relevant websites. RadiologyInfo.org , ACR ...

  17. Arthrography

    Medline Plus

    Full Text Available ... copied to CD. MRI does not use ionizing radiation (x-rays). CT direct arthrography uses the same type ... remains in a patient's body after an x-ray examination. X-rays usually have no side effects in the ...

  18. Arthrography

    Medline Plus

    Full Text Available ... related pain or inflammation and provide physicians additional information about possible sources of pain. top of page How should I prepare? No special preparation is necessary before direct arthrography. Food and fluid intake do not need to be restricted, unless a sedative will be ...

  19. Arthrography

    Medline Plus

    Full Text Available ... be asked to wear a gown. What is Direct Arthrography? What are some common uses of the procedure? How should I prepare? What does the equipment look like? How does the procedure work? How is the procedure performed? What will I ...

  20. Arthrography

    Medline Plus

    Full Text Available ... bear denotes child-specific content. Related Articles and Media Magnetic Resonance Imaging (MRI) - Musculoskeletal Radiation Dose in ... the web pages found at these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | ...

  1. Prospective, double-blind comparison of shoulder MR imaging, US, arthrography, and arthroscopy

    International Nuclear Information System (INIS)

    Resendes, M.; Drace, J.E.; Pyka, W.

    1988-01-01

    To determine the efficacy of diagnostic imaging modalities in the evaluation of shoulder pain, magnetic resonance (MR) imaging, ultrasonography (US) and arthrography were prospectively compared in a double-blind experimental protocol. Thirty consecutive patients were studied by these modalities, which received separate, blinded interpretations. The images and interpretations were sealed in an envelope and blinded from the arthroscopist for initial arthroscopy, but second-look arthroscopy, and in some cases open surgery, was performed after the envelopes were unsealed. To avoid selection bias, negative MR and/or US examinations never affected confirmation by arthrography and/or arthroscopy, so negatives and positives were equivalently tested. To date, MR imaging and US are equally sensitive in the detection of rotator cuff tears, but the combination is more sensitive. Both MR imaging and US demonstrated tears not diagnosed by means of arthrography, and MR imaging distinguished hemorrhagic muscle tears from rotator cuff tears, which arthrography and arthroscopy did not. Both MR imaging and US showed characteristic appearances of biceps tendonitis, but neither demonstrated adhesive capsulitis. The authors conclude that all three imaging modalities have a role in shoulder diagnosis

  2. Arthrography

    Medline Plus

    Full Text Available ... resonance imaging (MRI) or fluoroscopy – a form of real-time x-ray. Your preparation may vary depending on ... to see bones, joints and internal organs in real time. When iodine contrast is injected into the joint, ...

  3. Ankle ligamints : comparison of MR arthrography with conventional MR imaging in amputated feet

    International Nuclear Information System (INIS)

    Yoo, Jae Sung; Lee, Sang Yong; Lee, Jeong Min; Han, Young Min; Chung, Kyung Ho; Kim, CHong Soo

    2001-01-01

    To compare magnetic resonance (MR) arthrography with conventional MR imaging in the evaluation of ankle ligaments. Eight freshly amputated human feet underwent conventional MR imaging and MR arthrography. For the former, 1.5-T magnets in the axial, coronal and sagittal planes were used, and T1-weighted sequences were obtained. Following the injection of 6-10 ml of diluted contrast media (Gd-DTPA 1:250), T1-weighted images were obtained in the same positions as conventional MR images. Paired conventional MR imaging and MR arthrography of each ankle ligament were rated on a five-point scale, and to reflect inter-group differences a Wilcoxon singed-rank test was used to compare the different measurements (p<0.05). In two ankles, MR images of the ligaments were correlated with ankle dissection. Anterior and posterior talofibular ligaments were more clearly revealed by MR arthrography than by conventional MR imaging, while calcaneofibular ligaments showed no difference between these two modalities. With regard to deltoid ligaments, visualization of the anterior and posterior tibiotalar ligament was much improved when contrast material was used to outline the ligament's articular aspect. Visualization of the posterior inferior tibiofibular ligament and inferior transverse ligament were also improved when the use of contrast material provided delineation of the articular side of the ligaments and separated them from adjacent bone. In addition, MR arthography was very useful for indentification of the posterior intermalleolar ligament, though its use did not enhance visualization of the calcaneofibular, tibiocalcaneal, spring or tibiospring ligaments. MR arthrography accurately revealed the anatomic details of ankle ligaments, and may therefore be more useful than conventional Mr imaging for evaluation of these structures

  4. Imaging diagnostics of the wrist: MRI and Arthrography/Arthro-CT; Bildgebende Diagnostik des Handgelenkes: MRT und Arthrographie/Arthro-CT

    Energy Technology Data Exchange (ETDEWEB)

    Klein, H.M.; Balas, R.; Neugebauer, F. [Radiologische Gemeinschaftspraxis, Betzdorf (Germany); Vrsalovic, V. [Handchirugie, Marienhospital Siegen, Siegen (Germany)

    2002-02-01

    Purpose: To evaluate the use of magnetic resonance imaging (MRI) compared with arthrography and arthro-CT (AG/ACT) in patients with wrist pain. Methods: MRI and arthrography/arthro-CT (AG/ACT) of the wrist joint were retrospectively evaluated in 346 patients over a three-year period. Imaging findings were correlated to surgical results (n=78) or clinical course in an at least 6-month follow-up. Results: For tears of the triangular fibrocartilage, arthrography, arthro-CT, and MRI demonstrated a sensitivity and specificity of more than 0.96. Only the positive predictive value was superior for arthrography/arthro-CT (0.99 and 0.98, respectively) compared with MRI (0.94). Arthrography was superior for functional diagnosis of scapho-lunate ligament tears (n=25). Ulno-lunate and ulno-triquetral ligament defects were demonstrated more exactly by arthrography. Traumatic osseous defects, particularly scaphoid fractures (n=33) and avascular necrosis (n=17), were better diagnosed using MRI. Conclusion: For suspected lesions of the triangular fibrocartilage complex, AG/ACT is slightly more reliable than MRI. However, MRI was found to be highly accurate in diagnosing TFC tears, and is superior to AG/ACT in detecting traumatic and vascular lesions of the wrist. (orig.) [German] Ziel: Die Untersuchung der diagnostischen Aussagekraft von Magnetresonanz-Tomographie (MRT), Arthrographie (AG) und Arthro-CT (ACT) bei Erkrankungen des Handgelenkes. Methodik: Insgesamt 346 Untersuchungen des Handgelenkes wurden fuer einen dreijaehrigen Beobachtungszeitraum retrospektiv ausgewertet. Es wurden 211 MRT, 151 Arthrographien (AG) und 126 Arthro-CT (ACT) durchgefuehrt. Alle Diagnosen wurden operativ (n=78) oder durch den klinischen Verlauf in einer 6-monatigen Nachbeobachtung gesichert. Ergebnisse: Fuer die Diagnostik von Laesionen des diskoulnaren Komplexes lag die Sensitivitaet und Spezifitaet von AG, ACT und MRT ueber 0,96. Lediglich der positive Vorhersagewert differierte, allerdings nicht

  5. Arthrography

    Medline Plus

    Full Text Available ... radiologist or technologist may ask if you have asthma, or allergies of any kind, such as an ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Magnetic Resonance ...

  6. Arthrography

    Medline Plus

    Full Text Available ... material. top of page How does the procedure work? X-rays are a form of radiation like ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Magnetic Resonance ...

  7. Arthrography

    Medline Plus

    Full Text Available ... have a personal story about radiology? Share your patient story here Images × Image Gallery Musculoskeletal radiologist using fluoroscopic images to plan an ankle arthrogram. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  8. Arthrography

    Medline Plus

    Full Text Available ... is a type of medical imaging used to help evaluate and diagnose joint conditions and unexplained pain. ... ray (radiograph) is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Imaging with ...

  9. Arthrography

    Medline Plus

    Full Text Available ... affecting the MRI images, these objects can become projectiles within the MRI scanner room and may cause ... have no side effects in the typical diagnostic range for this exam. Exams involving MR imaging: MRI ...

  10. Arthrography

    Medline Plus

    Full Text Available ... the body. X-rays are the oldest and most frequently used form of medical imaging. Fluoroscopy makes ... involves taking radiographs for documentation. These images are most often stored and viewed electronically. Similarly, direct MR ...

  11. Arthrography

    Medline Plus

    Full Text Available ... a powerful magnetic field, radiofrequency pulses and a computer to produce detailed pictures of organs, soft tissues, ... The images can then be examined on a computer monitor connected to an image archive (PACS system) ...

  12. Arthrography

    Medline Plus

    Full Text Available ... distort images of the facial area or brain, so you should let the radiologist know about them. ... Many imaging tests are not performed during pregnancy so as not to expose the fetus to radiation. ...

  13. Arthrography

    Science.gov (United States)

    ... can then be examined on a computer monitor connected to an image archive (PACS system) or printed ... In addition to affecting the MRI images, these objects can become projectiles within the MRI scanner room ...

  14. Arthrography

    Medline Plus

    Full Text Available ... can then be examined on a computer monitor connected to an image archive (PACS system) or printed ... In addition to affecting the MRI images, these objects can become projectiles within the MRI scanner room ...

  15. Arthrography

    Medline Plus

    Full Text Available ... may be required prior to sedation. You should plan to have a relative or friend drive you ... Image Gallery Musculoskeletal radiologist using fluoroscopic images to plan an ankle arthrogram. View full size with caption ...

  16. Arthrography

    Medline Plus

    Full Text Available ... through the body, recording an image on photographic film or a special detector. Different parts of the ... recently, x-ray images were maintained on large film sheets (much like a large photographic negative). Today, ...

  17. Arthrography

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. Fluoroscopy uses a continuous or pulsed x-ray ... few seconds to a few minutes at a time. You will know when images are being recorded ...

  18. Arthrography

    Medline Plus

    Full Text Available ... frequently compared to current x-ray images for diagnosis and disease management. Fluoroscopy uses a continuous or ... usually have no side effects in the typical diagnostic range for this exam. Exams involving MR imaging: ...

  19. Arthrography

    Medline Plus

    Full Text Available ... usually have no side effects in the typical diagnostic range for this exam. Exams involving MR imaging: ... imaging: There is always a slight chance of cancer from excessive exposure to radiation. However, the benefit ...

  20. Arthrography

    Medline Plus

    Full Text Available ... it is useful to bring that to the attention of the scheduler before the exam and bring ... fluoroscopic images to plan an ankle arthrogram. View full size with caption Pediatric Content Some imaging tests ...

  1. Arthrography

    Medline Plus

    Full Text Available ... claustrophobia. Newer open MRI units provide very high quality images for many types of exams. Older open MRI units may not provide this same image quality. Certain types of exams cannot be performed using ...

  2. Arthrography

    Medline Plus

    Full Text Available ... information, consult your radiologist. The computer workstation that processes the imaging information is located in a separate ... in contact with the patient. A computer then processes the signals and generates a series of images, ...

  3. Arthrography

    Medline Plus

    Full Text Available ... you, notify the radiologist or technologist. It is important that you remain perfectly still while the images are being obtained, which is typically only a few seconds to a few minutes at a time. You will know when images are being recorded ...

  4. Arthrography

    Medline Plus

    Full Text Available ... ray examination. X-rays usually have no side effects in the typical diagnostic range for this exam. Exams involving MR imaging: MRI is a noninvasive imaging technique that does not involve exposure to ionizing radiation. MRI enables the discovery of abnormalities that might ...

  5. Arthrography

    Medline Plus

    Full Text Available ... ray examination. X-rays usually have no side effects in the typical diagnostic range for this exam. Exams involving MR imaging: MRI is a noninvasive imaging technique that does not involve exposure to ionizing radiation. MRI enables the discovery of ...

  6. Arthrography

    Medline Plus

    Full Text Available ... electronically reversing the image contrast to white), this special x-ray technique makes it possible for the physician to view joints or internal organs in motion. Still images or movies are also captured and stored electronically on a ...

  7. Arthrography

    Medline Plus

    Full Text Available ... to produce detailed pictures of organs, soft tissues, bone and virtually all other internal body structures. The images can then be examined on a computer monitor connected to an image archive (PACS system) or printed or copied to CD. MRI does not use ...

  8. Arthrography

    Medline Plus

    Full Text Available ... navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z ... is a type of medical imaging used to help evaluate and diagnose joint conditions and unexplained pain. It is very effective at ...

  9. Arthrography

    Medline Plus

    Full Text Available ... clothing that might interfere with the x-ray images. Women should always inform their physician and x-ray ... lowest radiation dose possible while producing the best images for ... organizations continually review and update the technique standards used ...

  10. Arthrography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site ...

  11. Arthrography

    Medline Plus

    Full Text Available ... images removable dental work pens, pocket knives and eyeglasses body piercings In most cases, an MRI exam ... and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media ...

  12. Arthrography

    Medline Plus

    Full Text Available ... the area being examined by making it appear dark (or by electronically reversing the image contrast to ... On very rare occasions, a few patients experience side effects from the contrast material, including nausea, headache ...

  13. Arthrography

    Medline Plus

    Full Text Available ... the exam. MRI scanners are air-conditioned and well-lit. Music may be played through the headphones ... full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy ...

  14. Arthrography

    Medline Plus

    Full Text Available ... a risk, depending on their nature and the strength of the MRI magnet. Many implanted devices will ... any possibility that they are pregnant. Many imaging tests are not performed during pregnancy so as not ...

  15. Arthrography

    Medline Plus

    Full Text Available ... of abnormal (diseased) tissue from normal tissues is better with MRI than with other imaging modalities such ... and/or your insurance provider to get a better understanding of the possible charges you will incur. ...

  16. Arthrography

    Medline Plus

    Full Text Available ... an ankle arthrogram. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  17. Arthrography

    Medline Plus

    Full Text Available ... nerve adjacent to the joint. Injury to these structures, however, is minimal particularly when the procedure is performed under ultrasound guidance. Exams involving x-ray imaging: There is always a slight chance of ...

  18. Arthrography

    Medline Plus

    Full Text Available ... metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings In most cases, an MRI exam is safe for patients with metal implants, except for a few types. ...

  19. Arthrography

    Medline Plus

    Full Text Available ... include a variety of needles, syringes and a water-soluble contrast material. top of page How does ... the setting of shoulder dislocation and in the hip, wrist and elbow. Exams involving x-ray imaging: ...

  20. Arthrography

    Medline Plus

    Full Text Available ... items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings In most cases, an MRI exam is safe for patients with metal implants, except for a ...

  1. Arthrography

    Medline Plus

    Full Text Available ... the joint thus allowing for enhanced imaging of small internal structures. This leads to improved evaluation of ... exposing a part of the body to a small dose of ionizing radiation to produce pictures of ...

  2. Arthrography

    Medline Plus

    Full Text Available ... an MRI scan, but this is rare. Tooth fillings and braces usually are not affected by the magnetic field, but they may distort images of the facial area or brain, so you should let the ...

  3. Arthrography

    Medline Plus

    Full Text Available ... examination also commonly involves taking radiographs for documentation. These images are most often stored and viewed electronically. ... into the joint along with the contrast material. These medications may temporarily decrease joint-related pain or ...

  4. Arthrography

    Medline Plus

    Full Text Available ... to identify abnormalities within the: shoulder elbow wrist hip knee ankle The procedure is often used to ... the setting of shoulder dislocation and in the hip, wrist and elbow. Exams involving x-ray imaging: ...

  5. Arthrography

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. Fluoroscopy uses a continuous or pulsed x-ray ... picture of the tissues scanned based on this information. The magnetic field is produced by passing an ...

  6. Arthrography

    Medline Plus

    Full Text Available ... metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings ... may also be asked to remove jewelry, removable dental appliances, eye glasses and any metal objects or ...

  7. Arthrography

    Medline Plus

    Full Text Available ... joint thus allowing for enhanced imaging of small internal structures. This leads to improved evaluation of diseases ... makes it possible to see bones, joints and internal organs in real time. When iodine contrast is ...

  8. Arthrography

    Medline Plus

    Full Text Available ... This website does not provide cost information. The costs for specific medical imaging tests, treatments and procedures may vary by geographic region. Discuss the fees associated with your prescribed procedure with your doctor, ...

  9. Arthrography

    Medline Plus

    Full Text Available ... computer monitor connected to an image archive (PACS system) or printed or copied to CD. MRI does ... the magnet. Some MRI units, called short-bore systems , are designed so that the magnet does not ...

  10. Arthrography

    Medline Plus

    Full Text Available ... medical imaging. Fluoroscopy makes it possible to see bones, joints and internal organs in real time. When ... within the joint, such as cartilage, ligaments and bones, and allows them to be evaluated by the ...

  11. Arthrography

    Medline Plus

    Full Text Available ... To locate a medical imaging or radiation oncology provider in your community, you can search the ACR- ... the medical facility staff and/or your insurance provider to get a better understanding of the possible ...

  12. Arthrography

    Medline Plus

    Full Text Available ... which may be sent to a laboratory for analysis. Aspiration is typically performed when an infection is ... ankle arthrogram. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric ...

  13. Arthrography

    Medline Plus

    Full Text Available ... the area being examined by making it appear dark (or by electronically reversing the image contrast to ... understanding of the possible charges you will incur. Web page review process: This Web page is reviewed ...

  14. Arthrography

    Medline Plus

    Full Text Available ... radiation oncology provider in your community, you can search the ACR-accredited facilities database . This website does not provide cost information. The costs for specific medical imaging tests, treatments ...

  15. Arthrography

    Medline Plus

    Full Text Available ... pregnant. Many imaging tests are not performed during pregnancy so as not to expose the fetus to ... See the Safety page for more information about pregnancy and x-rays. Though MRI does not use ...

  16. Arthrography

    Medline Plus

    Full Text Available ... type your comment or suggestion into the following text box: Comment: E-mail: Area code: Phone no: Thank ... View full size with caption Pediatric Content Some imaging tests ...

  17. Arthrography

    Medline Plus

    Full Text Available ... imaging (MRI) or fluoroscopy – a form of real-time x-ray. Your preparation may vary depending on ... see bones, joints and internal organs in real time. When iodine contrast is injected into the joint, ...

  18. Arthrography

    Medline Plus

    Full Text Available ... of which shows a thin slice of the body. The images can then be studied from different angles by ... bear denotes child-specific content. Related Articles and Media ... Videos related to Direct ...

  19. Arthrography

    Medline Plus

    Full Text Available ... care is taken during x-ray examinations to use the lowest radiation dose possible while producing the best images for evaluation. National and international radiology protection organizations continually review ...

  20. Arthrography

    Medline Plus

    Full Text Available ... computer monitor connected to an image archive (PACS system) or printed or copied to CD. MRI does ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose ...

  1. Arthrography

    Medline Plus

    Full Text Available ... in order to hold still for the procedure. Parents should ask about sedation before the procedure and ... part of the body being imaged, send and receive radio waves, producing signals that are detected by ...

  2. Arthrography

    Medline Plus

    Full Text Available ... it contains gadolinium, which affects the local magnetic field within the joint and appears on the MR ... images are produced. MRI uses a powerful magnetic field, radiofrequency pulses and a computer to produce detailed ...

  3. Arthrography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index ...

  4. Arthrography

    Medline Plus

    Full Text Available ... doctor if there’s a possibility that you are pregnant and discuss any recent illnesses, medical conditions, medications ... if there is any possibility that they are pregnant. Many imaging tests are not performed during pregnancy ...

  5. Arthrography

    Medline Plus

    Full Text Available ... ear) implant some types of clips used for brain aneurysms some types of metal coils placed within ... may distort images of the facial area or brain, so you should let the radiologist know about ...

  6. Arthrography

    Medline Plus

    Full Text Available ... rays. top of page What are some common uses of the procedure? Arthrographic images help physicians evaluate ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  7. Arthrography

    Medline Plus

    Full Text Available ... MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ... accredited facilities database . This website does not provide cost information. The costs for specific medical imaging tests, ...

  8. Arthrography

    Medline Plus

    Full Text Available ... that might interfere with the x-ray images. Women should always inform their physician and x-ray ... rays. Though MRI does not use ionizing radiation, women should still inform their physician and technologist if ...

  9. Arthrography

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. Fluoroscopy uses a continuous or pulsed x-ray ... joint area. You may feel pressure or even pain when the needle is advanced into the joint. ...

  10. Arthrography

    Medline Plus

    Full Text Available ... up in shades of gray and air appears black. Until recently, x-ray images were maintained on ... mild nausea to severe cardiovascular complications may result. Women should always inform their physician or x-ray ...

  11. Arthrography

    Medline Plus

    Full Text Available ... Examples include but are not limited to: artificial heart valves implanted drug infusion ports artificial limbs or ... to current x-ray images for diagnosis and disease management. Fluoroscopy uses a continuous or pulsed x- ...

  12. Arthrography

    Medline Plus

    Full Text Available ... no: Thank you! Do you have a personal story about radiology? Share your patient story here Images × ... Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2018 Radiological Society of North America, Inc. ( ...

  13. Arthrography

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. Fluoroscopy uses a continuous or pulsed x-ray ... are in the scanner without causing any chemical changes in the tissues. As the hydrogen atoms return ...

  14. Arthrography

    Medline Plus

    Full Text Available ... the area being examined by making it appear dark (or by electronically reversing the image contrast to ... their usual alignment, they emit different amounts of energy that vary according to the type of body ...

  15. Arthrography

    Medline Plus

    Full Text Available ... MRI examination poses almost no risk to the average patient when appropriate safety guidelines are followed. If ... accredited facilities database . This website does not provide cost information. The costs for specific medical imaging tests, ...

  16. Arthrography

    Medline Plus

    Full Text Available ... allowing the radiologist to assess the anatomy and function of the joint. Although the injection is typically ... images help physicians evaluate alterations in structure and function of a joint and help to determine the ...

  17. Arthrography

    Medline Plus

    Full Text Available ... pass through them. As a result, bones appear white on the x-ray, soft tissue shows up ... or by electronically reversing the image contrast to white), this special x-ray technique makes it possible ...

  18. Arthrography

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. Fluoroscopy uses a continuous or pulsed x-ray ... have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures ...

  19. Arthrography

    Medline Plus

    Full Text Available ... image on photographic film or a special detector. Different parts of the body absorb the x-rays in varying degrees. Dense ... atoms return to their usual alignment, they emit different amounts of energy that vary according to the type of body tissue from which they come. The MR scanner ...

  20. Arthrography

    Medline Plus

    Full Text Available ... types of clips used for brain aneurysms some types of metal coils placed within blood vessels nearly all cardiac defibrillators and pacemakers You should tell the technologist if you have medical or electronic devices in your ... high quality images for many types of exams. Older open MRI units may not ...

  1. Arthrography

    Medline Plus

    Full Text Available ... be damaged pins, hairpins, metal zippers and similar metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings In most cases, an MRI exam is safe for patients with metal implants, except for a few types. People with the ...

  2. Arthrography

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. Fluoroscopy uses a continuous or pulsed x-ray ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose ...

  3. Arthrography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... An x-ray (radiograph) is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  4. Arthrography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos ... unexplained pain. It is very effective at detecting disease within the ligaments, tendons and cartilage. It may ...

  5. Arthrography

    Medline Plus

    Full Text Available ... metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings In most cases, an MRI exam is safe for patients with metal implants, except for a few types. People with the ...

  6. Arthrography

    Medline Plus

    Full Text Available ... might be obscured by bone with other imaging methods. The contrast material used in MRI exams is less likely to produce an allergic reaction than the iodine-based contrast materials used for conventional x-rays and CT scanning. Risks Any procedure where the skin is penetrated carries ...

  7. Arthrography

    Medline Plus

    Full Text Available ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures that those parts of a patient's body not being imaged receive minimal radiation exposure. ...

  8. Arthrography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... they may move during the scan, possibly causing blindness. Dyes used in tattoos may contain iron and ...

  9. Arthrography

    Medline Plus

    Full Text Available ... MRI) or fluoroscopy – a form of real-time x-ray. Your preparation may vary depending on which imaging ... a joint often uses a special form of x-ray called fluoroscopy to guide and evaluate the injection ...

  10. Arthrography

    Medline Plus

    Full Text Available ... Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... minimize radiation exposure to the baby. See the Safety page for more information about pregnancy and x- ...

  11. Detection and staging of chondromalacia patellae: relative efficacies of conventional MR imaging, MR arthrography, and CT arthrography.

    Science.gov (United States)

    Gagliardi, J A; Chung, E M; Chandnani, V P; Kesling, K L; Christensen, K P; Null, R N; Radvany, M G; Hansen, M F

    1994-09-01

    Chondromalacia patellae is a condition characterized by softening, fraying, and ulceration of patellar articular cartilage. We compare the sensitivity, specificity, and accuracy of conventional MR imaging, MR arthrography, and CT arthrography in detecting and staging this abnormality. Twenty-seven patients with pain in the anterior part of the knee were prospectively examined with MR imaging, including T1-weighted (650/16), proton density-weighted (2000/20), T2-weighted (2000/80), and spoiled two-dimensional gradient-recalled acquisition in the steady state (SPGR/)/35 degrees (51/10) with fat saturation pulse sequences. All were also examined with T1-weighted MR imaging after intraarticular injection of dilute gadopentetate dimeglumine and with double-contrast CT arthrography. Each imaging technique was evaluated independently by two observers, who reached a consensus interpretation. The signal characteristics of cartilage on MR images and contour abnormalities noted with all imaging techniques were evaluated and graded according to a modification of the classification of Shahriaree. Twenty-six of the 54 facets examined had chondromalacia shown by arthroscopy, which was used as the standard of reference. The sensitivity, specificity, and accuracy of each imaging technique in the diagnosis of each stage of chondromalacia patellae were determined and compared by using the McNemar two-tailed analysis. Arthroscopy showed that 28 facets were normal. Grade 1 chondromalacia patellae was diagnosed only with MR and CT arthrography in two (29%) of seven facets. Intermediate (grade 2 or 3) chondromalacia patellae was detected in two (13%) of 15 facets with T1-weighted and SPGR MR imaging, in three (20%) of 15 facets with proton density-weighted MR imaging, in seven (47%) of 15 facets with T2-weighted MR imaging, in 11 (73%) of 15 facets with CT arthrography, and in 12 (80%) of 15 facets with MR arthrography. Grade 4 was detected in three (75%) of four facets with T1-, proton

  12. The detection of the capsular tear at the undersurface of the extensor carpi radialis brevis tendon in chronic tennis elbow: the value of magnetic resonance imaging and computed tomography arthrography.

    Science.gov (United States)

    Sasaki, Koichi; Tamakawa, Mitsuharu; Onda, Kazunori; Iba, Kosuke; Sonoda, Tomoko; Yamashita, Toshihiko; Wada, Takuro

    2011-04-01

    This study compared the diagnostic efficacy of magnetic resonance imaging (MRI) and computed tomography arthrography (CTA) in the assessment of capsular tears at the undersurface of the extensor carpi radials brevis tendon in chronic tennis elbow using arthroscopy as a gold standard. Because of the higher spatial resolution of CT, we hypothesized that CTA is superior to MRI for assessing capsular tears. We retrospectively reviewed 19 consecutive patients with chronic tennis elbow with preoperative MRI and CTA studies who underwent arthroscopic surgery. Three observers with different levels of training and experience (musculoskeletal radiologist, experienced elbow surgeon, and hand fellow) evaluated the capsular tear by MRI and CTA in a blinded manner. The results of the MRI and CTA were compared and the agreement among the 3 observers was determined using an intraclass correlation coefficient (ICC). Then, the results of the MRI and CTA examinations were compared with the intraoperative findings of the arthroscopic examination. The sensitivity, specificity, and κ value were calculated. The ICC of CTA (0.855) was superior to MRI (0.645). The sensitivity, specificity, and κ value of CTA were superior to those of MRI in each of the 3 observers. The κ value was 0.79, 0.89, and 0.79 for CTA, and 0.48, 0.48, and 0.27 for MRI for the radiologist, surgeon, and fellow, respectively. CTA was a reliable and accurate diagnostic modality compared with MRI to detect the capsular tear in patients with chronic tennis elbow. CTA was less influenced by the observer's experience. Copyright © 2011 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  13. Shoulder Magnetic Resonance Arthrography: A Prospective Randomized Study of Anterior and Posterior Ultrasonography-Guided Contrast Injections

    Energy Technology Data Exchange (ETDEWEB)

    Koivikko, M.P.; Mustonen, A.O.T. (Dept. of Radiology, Helsinki Univ. Central Hospital, Helsinki (Finland))

    2008-10-15

    Background: Magnetic resonance (MR) arthrography is an accurate imaging method for internal shoulder derangements and rotator cuff pathologies. Both anterior and posterior contrast injection techniques, under palpatory, fluoroscopic, or ultrasonographic guidance have been described in the literature. However, clinical comparisons of the injection techniques remain few. Purpose: To compare the performance of anterior and posterior ultrasonography (US)-guided arthrography injections of the shoulder regarding patient discomfort and influence on diagnostic MR reading, and to illustrate the typical artifacts resulting from contrast leakage in the respective techniques. Material and Methods: 43 MR arthrographies were prospectively randomized into anterior and posterior US-guided contrast injections and performed by two radiologists, with the study of artifacts from contrast leakage. Pain from the injections was assessed by a survey utilizing a 100-mm visual analogue scale (VAS). Results: Of the 23 anterior injections, nine caused contrast artifacts in the subscapular tendon, and in three the leakage extended further anteriorly. Of the 20 posterior injections, 12 showed injection artifacts of the rotator cuff, extending outside the cuff in seven. Two of the anterior and none of the posterior artifacts compromised diagnostic quality. In posterior injections, the leakage regularly occurred at the caudal edge of the infraspinatus muscle and was easily distinguishable from rotator cuff tears. All patients completed the pain survey. Mean VAS scores were 25.0 (median 18, SD 22) for anterior, and 25.4 (median 16, SD 25) for posterior injections. The two radiologists achieved different mean VAS scores but closely agreed as to anterior and posterior VAS scores. Conclusion: Arthrography injections were fairly simple to perform under US guidance. Patient discomfort for anterior and posterior injections was equally minor. A tailored approach utilizing anterior or posterior injections

  14. The Role of Wrist Magnetic Resonance Arthrography in Diagnosing Triangular Fibrocartilage Complex Tears; Experience at King Hussein Medical Center, Jordan

    Directory of Open Access Journals (Sweden)

    Asem A. Al-Hiari

    2013-05-01

    Full Text Available Objectives: The aims of the study were to evaluate the role of magnetic resonance arthrography (MRA of the wrist in detecting full-thickness tears of the triangular fibrocartilage complex (TFCC and to compare the results of the magnetic resonance arthrography (MRA with the gold standard arthroscopic findings. Methods:The study was performed at King Hussein Medical Center, Amman, Jordan, between January 2008 and December 2011. A total of 42 patients (35 males and 7 females who had ulnar-sided wrist pain and clinical suspicions of TFCC tears were included in the study. All patients underwent wrist magnetic resonance arthrography (MRA and then a wrist arthroscopy. The results of MRA were compared with the arthroscopic findings. Results: After comparison with the arthroscopic findings, the MRA had three false-negative results (sensitivity = 93% and no false-positive results. A total of 39 patients were able to return to work. Satisfaction was high in 38 of the patients and 33 had satisfactorypain relief. The sensitivity of the wrist MRA in detecting TFCC full-thickness tears was 93% (39, and specificity was 80% (16/20. The overall accuracy of wrist arthroscopy in detecting a full-thickness tear of the TFCC in our study was 85% (29/34. Conclusion: These results illustrate the role of wrist MRA in assessing the TFCC pathology and suggest its use as the first imaging technique, following a plain X-ray, in evaluating patients with chronic ulnar side wrist pain with suspected TFCC injuries.

  15. Comparative reliability and diagnostic performance of conventional 3T magnetic resonance imaging and 1.5T magnetic resonance arthrography for the evaluation of internal derangement of the hip

    Energy Technology Data Exchange (ETDEWEB)

    Chopra, A. [Chapel Allerton Hospital, Radiology Department, Leeds Teaching Hospitals, Leeds (United Kingdom); Grainger, A.J.; Robinson, Philip [Chapel Allerton Hospital, Radiology Department, Leeds Teaching Hospitals, Leeds (United Kingdom); Chapel Allerton Hospital, University of Leeds and NHIR Leeds Musculoskeletal Biomedical Research Centre, Leeds (United Kingdom); Dube, B.; Evans, R.; Hodgson, R. [Chapel Allerton Hospital, University of Leeds and NHIR Leeds Musculoskeletal Biomedical Research Centre, Leeds (United Kingdom); Conroy, J. [Harrogate and District NHS Trust, Trauma and Orthopaedics Department, Harrogate (United Kingdom); Macdonald, D. [Chapel Allerton Hospital, Trauma and Orthopaedics Department, Leeds Teaching Hospitals, Leeds (United Kingdom)

    2018-03-15

    To compare the diagnostic accuracy of conventional 3T MRI against 1.5T MR arthrography (MRA) in patients with clinical femoroacetabular impingement (FAI). Sixty-eight consecutive patients with clinical FAI underwent both 1.5T MRA and 3T MRI. Imaging was prospectively analysed by two musculoskeletal radiologists, blinded to patient outcomes and scored for internal derangement including labral and cartilage abnormality. Interobserver variation was assessed by kappa analysis. Thirty-nine patients subsequently underwent hip arthroscopy and surgical results and radiology findings were analysed. Both readers had higher sensitivities for detecting labral tears with 3T MRI compared to 1.5T MRA (not statistically significant p=0.07). For acetabular cartilage defect both readers had higher statistically significant sensitivities using 3T MRI compared to 1.5T MRA (p=0.02). Both readers had a slightly higher sensitivity for detecting delamination with 1.5T MRA compared to 3T MRI, but these differences were not statistically significant (p=0.66). Interobserver agreement was substantial to perfect agreement for all parameters except the identification of delamination (3T MRI showed moderate agreement and 1.5T MRA substantial agreement). Conventional 3T MRI may be at least equivalent to 1.5T MRA in detecting acetabular labrum and possibly superior to 1.5T MRA in detecting cartilage defects in patients with suspected FAI. circle Conventional 3T MRI is equivalent to 1.5T MRA for diagnosing labral tears. (orig.)

  16. Effects of iodinated contrast agent, xylocaine and gadolinium concentration on the signal emitted in magnetic resonance arthrography: a samples study

    Directory of Open Access Journals (Sweden)

    Yvana Lopes Pinheiro da Silva

    2015-04-01

    Full Text Available Objective: To investigate the effects of dilution of paramagnetic contrast agent with iodinated contrast and xylocaine on the signal intensity during magnetic resonance arthrography, and to improve the paramagnetic contrast agent concentration utilized in this imaging modality. Materials and Methods: Samples specially prepared for the study with three different concentrations of paramagnetic contrast agent diluted in saline, iodinated contrast agent and xylocaine were imaged with fast spin echo T1-weighted sequences with fat saturation. The samples were placed into flasks and graphical analysis of the signal intensity was performed as a function of the paramagnetic contrast concentration. Results: As compared with samples of equal concentrations diluted only with saline, the authors have observed an average signal intensity decrease of 20.67% for iodinated contrast agent, and of 28.34% for xylocaine. However, the increased gadolinium concentration in the samples caused decrease in signal intensity with all the dilutions. Conclusion: Minimizing the use of iodinated contrast media and xylocaine and/or the use of a gadolinium concentration of 2.5 mmol/L diluted in saline will improve the sensitivity of magnetic resonance arthrography.

  17. Ultrasound versus Magnetic Resonance Arthrography in Acetabular Labral Tear Diagnostics: A Prospective Comparison in 20 Dysplastic Hips

    Energy Technology Data Exchange (ETDEWEB)

    Troelsen, A.; Jacobsen, S.; Bolvig, L.; Gelineck, J.; Roemer, L.; Soeballe, K. [Orthopedic Research Unit and Dept. of Radiology, Univ. Hospital of Aarhus, A arhus (Denmark)

    2007-11-15

    Background: Acetabular labral tears are highly associated with hip dysplasia. Magnetic resonance arthrography (MR arthrography) is the expensive and time-consuming contemporary gold-standard method in the radiological assessment of acetabular labral tears. Purpose: To assess the diagnostic ability of noninvasive ultrasound (US) examination compared to MR arthrography in diagnosing acetabular labral tears in dysplastic hip joints. Material and Methods: The study compared US examination and MR arthrography diagnosis of labral tears in 20 consecutively referred dysplastic hip joints. Results: The ability to diagnose acetabular labral tears upon US examination was calculated: sensitivity 44%, specificity 75%, positive predictive value 88%, and negative predictive value 25%. Conclusion: The ability of US examination in diagnosing acetabular labral tears is not yet good enough. The technique is still to be developed, and more experience, especially with the interpretation of US examinations, is needed.

  18. MR arthrography: how I do it

    International Nuclear Information System (INIS)

    Bankaoglu, M.

    2012-01-01

    Full text: Magnetic resonance imaging has to rely on improving new various sequences and techniques and to get the best imaging quality so magnetic resonance (MR) arthrography is one of the most important technique in the assessment of selected musculoskeletal disorders. It is now widely utilized and considered by most musculoskeletal radiologists and some orthopedists to be an integral part of their clinical practice. The technique include: desired degree of joint distension with contrast medium; markedly improved imaging quality of intra-articular structures with the direct delineation so improved detection of pathology with MRI. As appliance and technique of MR arthrography is completely based on traditional arthrography of X ray. In MR arthrography additional very little amount of Gadolinium based contrast agent is added to the desired mixture of contrast material injected to the joint. As in conventional radiography MR arthrography is used to get extra information for conventional MRI . Practically any joint that can be accessed by a needle can be imaged using MR arthrography but it has been applied to limited number of joints to compare with the traditional arthrography so shoulder, knee, wrist, elbow, ankle, and hip are mostly subjects to do in MR arthrography. The procedure is also less invasive and expensive rather than diagnostic arthroscopy and should carefully indicated because it is not completely noninvasive technique so previous imaging modalities and MRI of the patients should be completed and evaluated well. During or after the procedure there has been no major complication reported by so far but more than two third of patients are known to complain some degree of pain right after or several times later than the procedure. As it is more than twenty years now it has been widely accepted helpful for diagnosis and adds some extra sensitivity to conventional MRI . Up to this time MR arthrography has proven to increase sensitivity of conventional MRI in

  19. The role of pubic symphyseal CT arthrography in the imaging of athletic pubalgia.

    Science.gov (United States)

    McArthur, Tatum A; Narducci, Carl A; Lopez-Ben, Robert R

    2014-11-01

    The purpose of this article is to describe the results of pubic symphyseal CT arthrography compared with MRI in patients with suspected athletic pubalgia. In this study, two musculoskeletal radiologists retrospectively searched our department's PACS to identify patients who had undergone CT-guided injection with concurrent pubic symphyseal CT arthrography for evaluation and treatment of groin pain, sports hernia, or athletic pubalgia over a 5.5-year period (January 1, 2007-July 1, 2012). The MR and CT arthrography images and reports, clinical findings at presentation, pain response to injection, and operative findings were reviewed using the electronic medical record. Twelve patients underwent CT-guided injection and pubic symphyseal CT arthrography at our institution during the 5.5-year study period. Nine of the 12 patients had undergone MRI before the procedure. In two of the three patients who had not undergone MRI, CT arthrography revealed secondary clefts. Three of four patients who had secondary clefts on MRI had contrast extravasation reproducing the cleft at CT. Three patients had MRI findings suggestive of athletic pubalgia without MRI evidence of a secondary cleft; in all three of these patients, CT arthrography showed a secondary cleft. In four patients, CT arthrography revealed tendon tears at the adductor origin that were not apparent on MRI. All 12 patients reported decreased groin pain after injection. Pubic symphyseal CT arthrography is a useful technique for the diagnosis and short-term pain relief of athletic pubalgia. It can be used to identify secondary clefts and to detect tendon tears that can potentially be overlooked on MRI.

  20. Triple correlation in temporomandibular joint dysfunction: MR imaging with arthrography, arthroscopy, and open surgery

    International Nuclear Information System (INIS)

    Rao, V.M.; Farole, A.; Karasick, D.

    1988-01-01

    Triple correlation of MR imaging with arthrography, arthroscopy, and open surgery was performed in 24 patients (34 temporomandibular joints) with ages ranging from 17 to 66 years. MR imaging showed disk position and morphologic features accurately in 30 joints (88%). It was false negative in one joint and false positive in three joints (9%). Degenerative changes were accurately detected with MR imaging, arthrography, and arthroscopy. Adhesions were diagnosed with arthrography in eight joints, arthroscopy in 14, and MR imaging in none. Disk perforations seen at open surgery were not detected with MR imaging. In conclusion, there is an overlap of information presented by various modalities. MR imaging is better than arthrography detecting disk morphologic features and displacement. Arthrography may add information by showing meniscal dynamics. Arthroscopy entails direct observation of superior joint space only and can detect adhesions and perforations better, but it may alter disk position and dynamics. In the more difficult cases, triple correlation may be needed, as modalities can be complementary

  1. Fluoroscopically-Guided Posterior Approach for Shoulder Magnetic Resonance Arthrography: Comparison with Conventional Anterior Approach

    International Nuclear Information System (INIS)

    Yoo, Koun J.; Ha, Doo Hoe; Lee, Sang Min

    2011-01-01

    To prospectively evaluate the usefulness of the fluoroscopically-guided posterior approach compared with the anterior approach for shoulder magnetic resonance(MR) arthrography. Institutional review board approval and informed consent were obtained. Among 60 shoulder MR arthrographies performed on 59 patients with symptomatic shoulders, an intra-articular injection was performed (30 cases using the anterior approach and 30 using the posterior approach). Procedure-related pain was assessed by using a 5 score visual analogue scale (VAS). Depth of the puncture and standardized depth of puncture by body mass index (BMI) were recorded. The contrast leakage along the course of the puncture was evaluated by reviewing the MR. The statistical analyses included the Mann-Whitney U and Kruskal-Wallis test. There was no significant difference in VAS scores between the anterior and posterior groups (1.77 ± 1.10 vs. 1.80 ± 0.96). Depth of puncture and standardized depth of puncture by BMI were significantly shorter in the posterior group than those in the anterior group (4.4 ± 0.8 cm and 1.8 ± 0.3 cm vs. 6.6 ± 0.9 cm and 2.8 ± 0.4 cm, p < 0.001), respectively. The incidence of contrast leakage was more frequent in the posterior group (p = 0.003). The posterior approach will be useful in shoulder MR arthrography with a suspected anterior pathology, a postoperative follow-up study or obese patient.

  2. A comparison of magnetic resonance arthrography and arthroscopic findings in the assessment of anterior shoulder dislocations

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, R.W.; Naeem, R.; Srinivas, K.; Shyamalan, G. [Birmingham Heartlands Hospital, Birmingham (United Kingdom)

    2015-05-01

    The aim of this study is to establish the sensitivity and specificity of MRA in the investigation of patients with traumatic anterior shoulder dislocations. A retrospective analysis of consecutive patients undergoing both magnetic resonance arthrography and arthroscopic assessment after a traumatic anterior shoulder dislocation between January 2011 and 2014 was performed. Demographic data were collected from electronic records. Images were interpreted by 8 musculoskeletal radiologists and patients were treated by 8 consultant orthopaedic surgeons. Arthroscopic findings were obtained from surgical notes and these findings were used as a reference for MRA. The sensitivity, specificity, and positive predictive value were calculated for the different injuries. Sixty-nine patients underwent both an MRA and shoulder arthroscopy during the study period; however, clinical notes were unavailable in 9 patients. Fifty-three patients (88 %) were male, the mean age was 28 years (range 18 to 50) and 16 subjects (27 %) had suffered a primary dislocation. The overall sensitivity and specificity of MRA to all associated injuries was 0.9 (CI 0.83-0.95) and 0.94 (CI 0.9-0.96) retrospectively. The lowest sensitivity was seen in osseous Bankart 0.8 (CI 0.44-0.96) and superior labral tear (SLAP) lesions 0.5 (CI 0.14-0.86). The overall positive predictive value was 0.88 (CI 0.76-0.91) with the lowest values found in rotator cuff 0.4 (CI 0.07-0.83) and glenohumeral ligament (GHL) lesions 0.29 (CI 0.05-0.7). Magnetic resonance angiography has a high sensitivity when used to identify associated injuries in shoulder dislocation, although in 8 patients (13 %) arthroscopy identified an additional injury. The overall agreement between MRA and arthroscopic findings was good, but the identification of GHL and rotator cuff injuries was poor. (orig.)

  3. A comparison of magnetic resonance arthrography and arthroscopic findings in the assessment of anterior shoulder dislocations

    International Nuclear Information System (INIS)

    Jordan, R.W.; Naeem, R.; Srinivas, K.; Shyamalan, G.

    2015-01-01

    The aim of this study is to establish the sensitivity and specificity of MRA in the investigation of patients with traumatic anterior shoulder dislocations. A retrospective analysis of consecutive patients undergoing both magnetic resonance arthrography and arthroscopic assessment after a traumatic anterior shoulder dislocation between January 2011 and 2014 was performed. Demographic data were collected from electronic records. Images were interpreted by 8 musculoskeletal radiologists and patients were treated by 8 consultant orthopaedic surgeons. Arthroscopic findings were obtained from surgical notes and these findings were used as a reference for MRA. The sensitivity, specificity, and positive predictive value were calculated for the different injuries. Sixty-nine patients underwent both an MRA and shoulder arthroscopy during the study period; however, clinical notes were unavailable in 9 patients. Fifty-three patients (88 %) were male, the mean age was 28 years (range 18 to 50) and 16 subjects (27 %) had suffered a primary dislocation. The overall sensitivity and specificity of MRA to all associated injuries was 0.9 (CI 0.83-0.95) and 0.94 (CI 0.9-0.96) retrospectively. The lowest sensitivity was seen in osseous Bankart 0.8 (CI 0.44-0.96) and superior labral tear (SLAP) lesions 0.5 (CI 0.14-0.86). The overall positive predictive value was 0.88 (CI 0.76-0.91) with the lowest values found in rotator cuff 0.4 (CI 0.07-0.83) and glenohumeral ligament (GHL) lesions 0.29 (CI 0.05-0.7). Magnetic resonance angiography has a high sensitivity when used to identify associated injuries in shoulder dislocation, although in 8 patients (13 %) arthroscopy identified an additional injury. The overall agreement between MRA and arthroscopic findings was good, but the identification of GHL and rotator cuff injuries was poor. (orig.)

  4. Diagnostic Accuracy and Inter-Observer Agreement of Shoulder Magnetic Resonance Arthrography in the Detection of Labral Lesion and Assessment of Lesion Location

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Ji Young; Song, Sook Yun; Choi, Jin Ha; Shin, Sang Jin [School of Medicine, Ewha Womans University, Mokdong Hospital, Seoul (Korea, Republic of)

    2012-11-15

    To evaluate the diagnostic accuracy and inter-observer agreement of magnetic resonance (MR) arthrography in the detection of labral lesions by location and to describe useful MR imaging findings of labral tears. Sixty-eight patients who underwent both pre-operative MR arthrography and arthroscopy were included. The location of the labrum was classified into anterior (2-6 o'clock), superior (12-2 o'clock), and posterior (6-12 o'clock). Sensitivity, specificity, accuracy, and inter-observer agreement of MR arthrography for the diagnosis of labral lesions by location were calculated. Frequency of MR imaging findings such as detachment, high signal intensity cleft, contour change, absence, and signal change of the labrum by location were analyzed. 35 anterior, 44 superior and 15 posterior labral lesions were detected by arthroscopy. The corresponding sensitivities were 91.4%, 79.5%, and 40.0%, specificities were 90.9%, 20.8%, and 86.8%, accuracies were 91.2%, 58.8%, and 76.5%, and kappa values were 0.823, 0.252, and 0.394, for anterior, superior, posterior lesions, respectively. The most common MR imaging findings were detachment in 60.0% of anterior labrums, high signal intensity cleft in 52.3% of superior labrums, and normal in 60.0% of posterior labrums. Diagnostic accuracy and inter-observer agreement of MR arthrography in the diagnosis of labral lesions are high in anterior labrums and low in superior or posterior labrums. The useful MR imaging findings of labral tears were different according to labral location.

  5. Magnetic resonance arthrography including ABER view in diagnosing partial-thickness tears of the rotator cuff: Accuracy, and inter- and intra-observer agreements

    International Nuclear Information System (INIS)

    Jung, Joon-Yong; Jee, Won-Hee; Chun, Ho Jong; Ahn, Myeong Im; Kim, Yang-Soo

    2010-01-01

    Background: Partial-thickness tear of the rotator cuff is a common cause of shoulder pain. Magnetic resonance (MR) arthrography has been described as a useful measure to diagnose rotator cuff abnormalities. Purpose: To determine the reliability and accuracy of MR arthrography with abduction and external rotation (ABER) view for the diagnosis of partial-thickness tears of the rotator cuff. Material and Methods: Among patients who underwent MR arthrographies, 22 patients (12 men, 10 women; mean age 45 years) who had either partial-thickness tear or normal tendon on arthroscopy were included. MR images were independently scored by two observers for partial-thickness tears of the rotator cuff. Interobserver and intraobserver agreements for detection of partial-thickness tears of the rotator cuff were calculated by using κ coefficients. The differences in areas under the receiver operating characteristic (ROC) curves were assessed with a univariate Z-score test. Differences in sensitivity and specificity for interpretations based on different imaging series were tested for significance using the McNemar statistic. Results: Sensitivity, specificity, and accuracy of each reader on MR imaging without ABER view were 83%, 90%, and 86%, and 83%, 80%, and 82%, respectively, whereas on overall interpretation including ABER view, the sensitivity, specificity, and accuracy of each reader were 92%, 70%, and 82%, and 92%, 80%, and 86%, respectively. Including ABER view, interobserver agreement for partial-thickness tear increased from κ=0.55 to κ=0.68. Likewise, intraobserver agreements increased from κ=0.79 and 0.53 to κ=0.81 and 0.70 for each reader, respectively. The areas under the ROC curves for each reader were 0.96 and 0.90, which were not significantly different. Conclusion: Including ABER view in routine sequences of MR arthrography increases the sensitivity, and inter- and intraobserver agreements for detecting partial-thickness tear of rotator cuff tendon

  6. Magnetic resonance arthrography including ABER view in diagnosing partial-thickness tears of the rotator cuff: Accuracy, and inter- and intra-observer agreements

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Joon-Yong; Jee, Won-Hee; Chun, Ho Jong; Ahn, Myeong Im (Dept. of Radiology, Seoul St. Mary' s Hospital, School of Medicine, Catholic Univ. of Korea, Seoul (Korea)), e-mail: whjee@catholic.ac.kr; Kim, Yang-Soo (Dept. of Orthopedic Surgery, Seoul St. Mary' s Hospital, School of Medicine, Catholic Univ. of Korea, Seoul (Korea))

    2010-03-15

    Background: Partial-thickness tear of the rotator cuff is a common cause of shoulder pain. Magnetic resonance (MR) arthrography has been described as a useful measure to diagnose rotator cuff abnormalities. Purpose: To determine the reliability and accuracy of MR arthrography with abduction and external rotation (ABER) view for the diagnosis of partial-thickness tears of the rotator cuff. Material and Methods: Among patients who underwent MR arthrographies, 22 patients (12 men, 10 women; mean age 45 years) who had either partial-thickness tear or normal tendon on arthroscopy were included. MR images were independently scored by two observers for partial-thickness tears of the rotator cuff. Interobserver and intraobserver agreements for detection of partial-thickness tears of the rotator cuff were calculated by using kappa coefficients. The differences in areas under the receiver operating characteristic (ROC) curves were assessed with a univariate Z-score test. Differences in sensitivity and specificity for interpretations based on different imaging series were tested for significance using the McNemar statistic. Results: Sensitivity, specificity, and accuracy of each reader on MR imaging without ABER view were 83%, 90%, and 86%, and 83%, 80%, and 82%, respectively, whereas on overall interpretation including ABER view, the sensitivity, specificity, and accuracy of each reader were 92%, 70%, and 82%, and 92%, 80%, and 86%, respectively. Including ABER view, interobserver agreement for partial-thickness tear increased from kappa=0.55 to kappa=0.68. Likewise, intraobserver agreements increased from kappa=0.79 and 0.53 to kappa=0.81 and 0.70 for each reader, respectively. The areas under the ROC curves for each reader were 0.96 and 0.90, which were not significantly different. Conclusion: Including ABER view in routine sequences of MR arthrography increases the sensitivity, and inter- and intraobserver agreements for detecting partial-thickness tear of rotator cuff

  7. Diagnostic value of MRI in meniscus injury. Comparison of MRI and arthrography

    International Nuclear Information System (INIS)

    Iso, Yoshinori; Nozaki, Hiroyuki; Emoto, Mari; Miyairi, Taro; Hirata, Aya; Hirasawa, Seiichi; Suguro, Toru; Igata, Atsuomi; Kudo, Yukihiko.

    1995-01-01

    Magnetic resonance imaging (MRI) and arthrography were performed on 90 knees to compare the diagnostic value for meniscus injury with these techniques. The diagnostic accuracy of MRI and arthrography was 89.1% and 87.1%, respectively. Imaging of the medial meniscus was somewhat better with arthrography, and delineation of the lateral meniscus was somewhat better with MRI. MRI was superior in diagnoses of horizontal and degenerative lacerations, but showed the shape of the injuries less clearly than arthrography. The diagnostic accuracy of MRI decreased with the age of the patients and was inferior to arthrography for patients in their forties or older. In conclusion, MRI is a less invasive approach with high diagnostic accuracy for meniscus injury and is a promising substitute for arthrography. (author)

  8. Ultrasound guidance to perform intra-articular injection of gadolinium-based contrast material for magnetic resonance arthrography as an alternative to fluoroscopy: the time is now

    Energy Technology Data Exchange (ETDEWEB)

    Messina, Carmelo [Universita degli Studi di Milano, Scuola di Specializzazione in Radiodiagnostica, Milano (Italy); Banfi, Giuseppe [IRCCS Istituto Ortopedico Galeazzi, Milano (Italy); Universita Vita-Salute San Raffaele, Milano (Italy); Aliprandi, Alberto [Universita degli Studi di Milano, Dipartimento di Scienze Biomediche per la Salute, Milano (Italy); Mauri, Giovanni [Universita degli Studi di Milano, Dipartimento di Scienze Biomediche per la Salute, Milano (Italy); Istituto Europeo di Oncologia, Unita di Radiologia Interventistica, Milano (Italy); Secchi, Francesco; Sardanelli, Francesco; Sconfienza, Luca Maria [Universita degli Studi di Milano, Dipartimento di Scienze Biomediche per la Salute, Milano (Italy); IRCCS Policlinico San Donato, Servizio di Radiologia, San Donato, Milanese (Italy)

    2016-05-15

    Magnetic resonance (MR) imaging has been definitively established as the reference standard in the evaluation of joints in the body. Similarly, magnetic resonance arthrography has emerged as a technique that has been proven to increase significantly the diagnostic performance if compared with conventional MR imaging, especially when dealing with fibrocartilage and articular cartilage abnormalities. Diluted gadolinium can be injected in the joint space using different approaches: under palpation using anatomic landmarks or using an imaging guidance, such as fluoroscopy, computed tomography, or ultrasound. Fluoroscopy has been traditionally used, but the involvement of ionizing radiation should represent a remarkable limitation of this modality. Conversely, ultrasound has emerged as a feasible, cheap, quick, and radiation-free modality that can be used to inject joints, with comparable accuracy of fluoroscopy. In the present paper, we discuss the advantages and disadvantages of using fluoroscopy or ultrasound in injecting gadolinium-based contrast agents in joints to perform magnetic resonance arthrography, also in view of the new EuroSAFE Imaging initiative promoted by the European Society of Radiology and the recent updates to the European Atomic Energy Community 2013/59 directive on the medical use of ionizing radiation. (orig.)

  9. The hamatolunate facet: characterization and association with cartilage lesions - magnetic resonance arthrography and anatomic correlation in cadaveric wrists

    Energy Technology Data Exchange (ETDEWEB)

    Pfirrmann, C.W.A. [Department of Radiology, Veterans Administration Medical Center, 3350 La Jolla Village Dr., San Diego, CA 92161 (United States); Orthopedic University Hospital Balgrist, Department of Radiology, Forchstrasse 340, 8008 Zurich (Switzerland); Theumann, N.H.; Chung, C.B.; Trudell, D.J.; Resnick, D. [Department of Radiology, Veterans Administration Medical Center, 3350 La Jolla Village Dr., San Diego, CA 92161 (United States)

    2002-08-01

    The objective of this study was to characterize the appearance of the hamatolunate facet using high-resolution magnetic resonance (MR) arthrography in cadavers and to correlate the presence of this anatomic variant with the presence of osteoarthritis in the wrist. High-resolution MR images of 22 cadaveric wrist specimens were obtained after tri-compartmental arthrography. Two readers in consensus analyzed the MR images and recoded the presence or absence of a hamatolunate facet. Geometric characteristics and cartilage and ligament integrity were analyzed. A third reader, who was blinded to the purpose of the study, recorded cartilage lesions of all the bones of the proximal and distal carpal rows. A hamatolunate facet was present in 11 of 22 wrists (50%). The mean coronal size of the lunate facet at the lunate (type II lunate) was 4.5 mm (range, 2-6 mm). The highest frequencies of cartilage lesions were seen in the scapho-trapezio-trapezoid joint (45.5%) and at the proximal pole of the hamate (54.4% and 40.9% for consensus reading/blinded reading, respectively). In cases with a hamatolunate facet, the frequency of cartilage lesions in the proximal pole of the hamate was 81.8% and 63.6% versus 27.3% and 18.2% without such a facet (chi-squared, P=0.01/P=0.03). No correlation of the presence of a hamatolunate facet with interosseous ligament tears or lesions of the triangular fibrocartilage was seen. In conclusion, the hamatolunate facet is a very common anatomic variant. The presence of a hamatolunate facet is associated with cartilage damage in the proximal pole of the hamate. (orig.)

  10. The preliminary application of magnetic resonance arthrography in the diagnosis of acetabular labrale tears

    International Nuclear Information System (INIS)

    Hong Wen; Zhang Xuezhe; Wang Wu; Yue Debo; Wang Weiguo

    2010-01-01

    Objective: To investigate the application value of MR arthrography (MRA) in the diagnosis of acetabular lab ral tears. Methods: Fifteen patients with a high degree of suspected acetabular lab ral tears received fluoroscope-guided injection of the contrast media into the hip joint (hip arthrography) and fat-saturated spin-echo T 1 -weighted images were obtained in the coronal, sagittal, oblique-axial and radial planes. Hip arthroscopy was performed on 12 of them. Results: Lab ral tears which were diagnosed in 11 patients by hip MRA were confirmed at hip arthroscopy. One patient showed no MRA indication of lab ral tear, also showed normal on arthroscopy. Tear in the anterior-superior quadrant 10 cases of 12 joints (12/13), posterior-superior quadrant 1 case of a joint (1/13). In 11 patients who underwent arthroscopy, hip MRA diagnosed 3 (3/13) joints labrale tears in coronal planes, 10 (10/13) joints in sagittal planes and 13 (13/13) labrale tears in axial-oblique and radial planes. In 15 patients with 20 hip joints, 5 cases 6 joints (6/20) with normal acetabular sublabral sulcus were performed. Conclusions: MR arthrography of hip is a reliable method in the diagnosis of acetabular labrale tears. Scanning method should be included fat-saturated spin-echo T 1 -weighted images in sagittal and oblique-axial planes or sagittal plus radial planes. The diagnosis of torn posterior-inferior quadrant should pay attention to the existence of a normal variation. (authors)

  11. Magnetic resonance arthrography of the shoulder: accuracy of gadolinium versus saline for rotator cuff and labral pathology

    Energy Technology Data Exchange (ETDEWEB)

    Helms, Clyde A.; McGonegle, Shane J.; Vinson, Emily N.; Whiteside, Michael B. [Duke University Medical Center, Department of Radiology, Durham, NC (United States)

    2011-02-15

    The purpose of this study was to evaluate the necessity of intra-articular gadolinium versus saline alone in magnetic resonance arthrography (MRA) of the shoulder. Our database was reviewed for 100 consecutive shoulder MRA examinations performed between January 2007 and December 2007. Patient information was blinded and images were retrospectively reviewed by at least two radiologists with dedicated musculoskeletal training. T2-weighted (T2W) images were initially analyzed in isolation to simulate MRA with saline alone. After a delay, the full study was analyzed including T1-weighted (T1W) and T2W images. If there was a significant discordance between the two analyses with regard to rotator cuff or labral pathology, the study was again reviewed by all evaluators in consensus to determine if the T1W images offered additional diagnostic information and increased diagnostic confidence. Of the 100 MRA examinations, there were 15 discordant cases. Two cases were discordant with regard to rotator cuff pathology and 13 were discordant on the basis of labral pathology. When the discordant cases were reviewed in consensus, the T2W images appeared to display rotator cuff and labral pathology as definitively as the T1W images. Interobserver and intraobserver variability was favored to have played a role in causing the discordances. MRA of the shoulder performed with joint distention provided by saline alone appears to offer equivalent diagnostic information to MRA performed with gadolinium enhancement. This protocol modification improves efficiency by eliminating several image series and provides a small cost savings by eliminating gadolinium. (orig.)

  12. Magnetic resonance arthrography of the shoulder: accuracy of gadolinium versus saline for rotator cuff and labral pathology

    International Nuclear Information System (INIS)

    Helms, Clyde A.; McGonegle, Shane J.; Vinson, Emily N.; Whiteside, Michael B.

    2011-01-01

    The purpose of this study was to evaluate the necessity of intra-articular gadolinium versus saline alone in magnetic resonance arthrography (MRA) of the shoulder. Our database was reviewed for 100 consecutive shoulder MRA examinations performed between January 2007 and December 2007. Patient information was blinded and images were retrospectively reviewed by at least two radiologists with dedicated musculoskeletal training. T2-weighted (T2W) images were initially analyzed in isolation to simulate MRA with saline alone. After a delay, the full study was analyzed including T1-weighted (T1W) and T2W images. If there was a significant discordance between the two analyses with regard to rotator cuff or labral pathology, the study was again reviewed by all evaluators in consensus to determine if the T1W images offered additional diagnostic information and increased diagnostic confidence. Of the 100 MRA examinations, there were 15 discordant cases. Two cases were discordant with regard to rotator cuff pathology and 13 were discordant on the basis of labral pathology. When the discordant cases were reviewed in consensus, the T2W images appeared to display rotator cuff and labral pathology as definitively as the T1W images. Interobserver and intraobserver variability was favored to have played a role in causing the discordances. MRA of the shoulder performed with joint distention provided by saline alone appears to offer equivalent diagnostic information to MRA performed with gadolinium enhancement. This protocol modification improves efficiency by eliminating several image series and provides a small cost savings by eliminating gadolinium. (orig.)

  13. MRI (Magnetic Resonance Imaging)

    Science.gov (United States)

    ... Procedures Medical Imaging MRI (Magnetic Resonance Imaging) MRI (Magnetic Resonance Imaging) Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print Magnetic Resonance Imaging (MRI) is a medical imaging procedure for ...

  14. Wrist arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Fransson, S.G. (Dept. of Diagnostic Radiology, University Hospital, Linkoeping (Sweden))

    1993-03-01

    The ligaments of the proximal row of carpal bones and the triangular fibrocartilage (TFC) strongly influence the function and stability of the wrist. Injury to the ligaments may result in chronic wrist pain or instability. Wrist arthrography is valuable in the investigation of such damage when surgical intervention is considered and plain radiography is unrewarding. There are also several technical modifications of the standard radiocarpal arthrography available. Owing to the possibility of congential perforations and degenerative changes in these ligaments the arthrographic findings should be related to the clinical signs and the age of the patient. CT has less diagnostic importance in this respect while MR imaging is an alternative and may become the method of choice. Both these methods have great potential in the evaluation of soft tissues of the wrist other than the TFC. (orig.).

  15. MR arthrography of the knee

    International Nuclear Information System (INIS)

    Kramer, J.; Engel, A. Jr.; Stiglbauer, R. Jr.; Prayer, L. Jr.; Hajek, P. Jr.; Imhof, H.

    1991-01-01

    This paper demonstrates the diagnostic value of MR arthrography in the assessment of cartilaginous lesions, including osteochondritis dissecans. One hundred thirty-two knees of 125 patients were examined with MR arthrography performed on a 1.5-T magnet with a knee resonator. T1-weighted spin-echo and T2*-weighted three-dimensional gradient-echo sequences were obtained after intraarticular administration of 40 mL of 2-mmol GD-DTPA solution. Seventy-five patients were also imaged without contrast agent. The description of the articular surface was classified into four types: I, normal cartilage surface and thickness; II, surface normal or slightly irregular; III, severe surface irregularities and cartilage defects; and IV, extensive cartilage defects, scar formation. MR findings were correlated with those of arthroscopy/arthrotomy (n = 75)

  16. Diagnostic value of US, CT arthrography, and 0.5-T MR imaging of lesions of the biceps tendon

    International Nuclear Information System (INIS)

    Saez, F.; Elizagaray, E.; Pena, J.M.; Ferrero, A.; Azkuna, I.; Larrea, L.

    1990-01-01

    This paper evaluates the role of US, CT-arthrography, and MR imaging in lesions in the tendon of the long head of the biceps brachii and bicipital groove. One hundred fifty-four patients with painful shoulder were prospectively studied by means of US and axial CT-arthrography, and 45 of them were also examined with 0.5-T MR imaging. Fifty-three (34.4%) patients showed biceps tendon or bicipital groove abnormalities; including 34 bicipital groove bone spurs, 31 cases of tendinitis, eight intraarticular ruptures, four subluxations, and eight medial dislocations

  17. Texture analysis of torn rotator cuff on preoperative magnetic resonance arthrography as a predictor of postoperative tendon status

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Yeon Ah; Lee, Guen Young; Lee, Joon Woo; Lee, Eugene; Kim, Boh Young; Kim, Su Jin; Ahn, Joong Mo; Kang, Heung Sik [Dept. of Radiology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2017-08-01

    To evaluate texture data of the torn supraspinatus tendon (SST) on preoperative T2-weighted magnetic resonance arthrography (MRA) using the gray-level co-occurrence matrix (GLCM) for prediction of post-operative tendon state. Fifty patients who underwent arthroscopic rotator cuff repair for full-thickness tears of the SST were included in this retrospective study. Based on 1-year follow-up, magnetic resonance imaging showed that 30 patients had intact SSTs, and 20 had rotator cuff retears. Using GLCM, two radiologists measured independently the highest signal intensity area of the distal end of the torn SST on preoperative T2-weighted MRA, which were compared between two groups.The relationships with other well-known prognostic factors, including age, tear size (anteroposterior dimension), retraction size (mediolateral tear length), grade of fatty degeneration of the SST and infraspinatus tendon, and arthroscopic fixation technique (single or double row), also were evaluated. Of all the GLCM features, the retear group showed significantly higher entropy (p < 0.001 and p = 0.001), variance (p = 0.030 and 0.011), and contrast (p = 0.033 and 0.012), but lower angular second moment (p < 0.001 and p = 0.002) and inverse difference moment (p = 0.027 and 0.027), as well as larger tear size (p = 0.001) and retraction size (p = 0.002) than the intact group. Retraction size (odds ratio [OR] = 3.053) and entropy (OR = 17.095) were significant predictors. Texture analysis of torn SSTs on preoperative T2-weighted MRA using the GLCM may be helpful to predict postoperative tendon state after rotator cuff repair.

  18. Texture analysis of torn rotator cuff on preoperative magnetic resonance arthrography as a predictor of postoperative tendon status

    International Nuclear Information System (INIS)

    Kang, Yeon Ah; Lee, Guen Young; Lee, Joon Woo; Lee, Eugene; Kim, Boh Young; Kim, Su Jin; Ahn, Joong Mo; Kang, Heung Sik

    2017-01-01

    To evaluate texture data of the torn supraspinatus tendon (SST) on preoperative T2-weighted magnetic resonance arthrography (MRA) using the gray-level co-occurrence matrix (GLCM) for prediction of post-operative tendon state. Fifty patients who underwent arthroscopic rotator cuff repair for full-thickness tears of the SST were included in this retrospective study. Based on 1-year follow-up, magnetic resonance imaging showed that 30 patients had intact SSTs, and 20 had rotator cuff retears. Using GLCM, two radiologists measured independently the highest signal intensity area of the distal end of the torn SST on preoperative T2-weighted MRA, which were compared between two groups.The relationships with other well-known prognostic factors, including age, tear size (anteroposterior dimension), retraction size (mediolateral tear length), grade of fatty degeneration of the SST and infraspinatus tendon, and arthroscopic fixation technique (single or double row), also were evaluated. Of all the GLCM features, the retear group showed significantly higher entropy (p < 0.001 and p = 0.001), variance (p = 0.030 and 0.011), and contrast (p = 0.033 and 0.012), but lower angular second moment (p < 0.001 and p = 0.002) and inverse difference moment (p = 0.027 and 0.027), as well as larger tear size (p = 0.001) and retraction size (p = 0.002) than the intact group. Retraction size (odds ratio [OR] = 3.053) and entropy (OR = 17.095) were significant predictors. Texture analysis of torn SSTs on preoperative T2-weighted MRA using the GLCM may be helpful to predict postoperative tendon state after rotator cuff repair

  19. Magnetic resonance arthrography and the prevalence of acetabular labral tears in patients 50 years of age and older

    International Nuclear Information System (INIS)

    Jayakar, Rohit; Merz, Alexa; Wang, Dean; Hame, Sharon L.; Plotkin, Benjamin; Seeger, Leanne

    2016-01-01

    Arthroscopy for acetabular labral tears has minimal impact on pain and function in older patients, especially in the setting of concomitant osteoarthritis. Still, many physicians seek this diagnosis with MR arthrography. Our purpose is to assess the frequency of acetabular labral tears in older patients with hip pain and correlate likelihood of labral pathology with severity of osteoarthritis as visualized on conventional radiograph. From 2004 to 2013, 208 hip MRI arthrograms and corresponding radiographs on patients aged 50 years and older were identified. Age, gender, grade and location of labral tear, alpha angle, Toennis grade, and joint space width were documented. Labral tears and alpha angle were identified and measured on MR arthrogram. Toennis grade and joint space width were measured on radiographs. On MR arthrography, true labral tearing was identified in 73 % of patients. There was some degree of labral pathology in 93.3 % of patients, and this increased to 100 % in patients with moderate to severe osteoarthritis, as defined by Toennis grade 2-3 or joint space width ≤ 2 mm. There were no statistically significant correlations between labral tear grade and Toennis grade or joint space width. Given the high frequency of labral pathology and the questionable efficacy of arthroscopic surgical intervention in older patients, MR arthrography should be primarily for those with minimal arthritis on radiograph and potential to benefit from surgery. If further imaging beyond radiographs is necessary in these patients, standard MRI may be a more appropriate imaging tool. (orig.)

  20. Indirect magnetic resonance arthrography of the shoulder; a reliable diagnostic tool for investigation of suspected labral pathology

    Energy Technology Data Exchange (ETDEWEB)

    Fallahi, Farshid [North Cumbria University Hospitals NHS Trust, Carlisle (United Kingdom); North Cumbria University Hospitals, Department of Radiology, Carlisle (United Kingdom); Green, Nick; Gadde, Sarat; Jeavons, Lisa; Armstrong, Patrick; Jonker, Leon [North Cumbria University Hospitals NHS Trust, Carlisle (United Kingdom)

    2013-09-15

    Indirect magnetic resonance arthrography (I-MRA) confers significant logistical advantages over direct MRA and does not require articular injection. In this study, we determined the diagnostic performance of I-MRA in relation to conventional MRI and arthroscopy or surgery in detecting tears of the glenoid labrum, including Bankart lesions and superior labral antero-posterior (SLAP) tears in a standard clinical setting. Ninety-one symptomatic patients underwent conventional MRI and I-MRA of the affected shoulder, followed by either arthroscopy or open surgery. The scans were interpreted independently by two experienced radiology consultants with a special interest in musculoskeletal radiology. Using the surgical findings as the standard of reference, sensitivity, specificity, and diagnostic accuracy of conventional non-contrast MRI and I-MRA in the detection of labral tears were calculated. The sensitivity of I-MRA was 95 and 97 %, respectively, for two radiologists as opposed to 79 and 83 % for conventional MRI. For both radiologists, the specificity of I-MRA, as well as MRI, was 91 % for detection of labral tears of all types. Accuracy of diagnosis was 93 and 95 %, respectively, for two radiologists with indirect MRA, compared to 84 and 86 % with non-contrast MRI. This retrospective study shows that I-MRA is a highly accurate and sensitive method for the detection of labral tears. The data obtained supports the use of I-MRA as standard practice in patients with shoulder instability due to suspected labral pathology where further investigative imaging is indicated. (orig.)

  1. Indirect magnetic resonance arthrography of the shoulder; a reliable diagnostic tool for investigation of suspected labral pathology

    International Nuclear Information System (INIS)

    Fallahi, Farshid; Green, Nick; Gadde, Sarat; Jeavons, Lisa; Armstrong, Patrick; Jonker, Leon

    2013-01-01

    Indirect magnetic resonance arthrography (I-MRA) confers significant logistical advantages over direct MRA and does not require articular injection. In this study, we determined the diagnostic performance of I-MRA in relation to conventional MRI and arthroscopy or surgery in detecting tears of the glenoid labrum, including Bankart lesions and superior labral antero-posterior (SLAP) tears in a standard clinical setting. Ninety-one symptomatic patients underwent conventional MRI and I-MRA of the affected shoulder, followed by either arthroscopy or open surgery. The scans were interpreted independently by two experienced radiology consultants with a special interest in musculoskeletal radiology. Using the surgical findings as the standard of reference, sensitivity, specificity, and diagnostic accuracy of conventional non-contrast MRI and I-MRA in the detection of labral tears were calculated. The sensitivity of I-MRA was 95 and 97 %, respectively, for two radiologists as opposed to 79 and 83 % for conventional MRI. For both radiologists, the specificity of I-MRA, as well as MRI, was 91 % for detection of labral tears of all types. Accuracy of diagnosis was 93 and 95 %, respectively, for two radiologists with indirect MRA, compared to 84 and 86 % with non-contrast MRI. This retrospective study shows that I-MRA is a highly accurate and sensitive method for the detection of labral tears. The data obtained supports the use of I-MRA as standard practice in patients with shoulder instability due to suspected labral pathology where further investigative imaging is indicated. (orig.)

  2. MR-guided direct arthrography of the glenohumeral joint

    International Nuclear Information System (INIS)

    Soh, E.; Bearcroft, P.W.P.; Graves, M.J.; Black, R.; Lomas, D.J.

    2008-01-01

    Aim: To evaluate the feasibility of magnetic resonance (MR)-guided direct arthrography of the glenohumeral joint with a 1.5 T MR system, performing the entire procedure in a single MR examination. Materials and methods: MR-guided direct arthrography was performed on 11 patients. MR imaging guidance and interactive MR fluoroscopy, with in-room control and display system, were used for needle placement and contrast medium injection. The outcome measures were success or failure of joint puncture, the time taken for introduction of contrast medium, and the diagnostic quality of the subsequent MR arthrography images. Results: Contrast medium was successfully instilled into the joint and diagnostic quality MR arthrography images were obtained in all cases. The median time from initial placement of the skin marker to introduction of the contrast medium was 17 min (range 11-29 min). There were no immediate post-procedure complications. Conclusion: Accurate needle placement is feasible in a single MR examination on a commercial 1.5 T closed-bore MR system, using an in-room control and display system together with interactive fluoroscopic imaging, and this was used to provide direct MR arthrography in this study

  3. Pediatric magnetic resonance imaging

    International Nuclear Information System (INIS)

    Cohen, M.D.

    1986-01-01

    This book defines the current clinical potential of magnetic resonance imaging and focuses on direct clinical work with pediatric patients. A section dealing with the physics of magnetic resonance imaging provides an introduction to enable clinicians to utilize the machine and interpret the images. Magnetic resonance imaging is presented as an appropriate imaging modality for pediatric patients utilizing no radiation

  4. Evaluation of patellar cartilage surface lesions: comparison of CT arthrography and fat-suppressed FLASH 3D MR imaging

    International Nuclear Information System (INIS)

    Daenen, B.R.; Ferrara, M.A.; Marcelis, S.; Dondelinger, R.F.

    1998-01-01

    The aim of this study was to evaluate the sensitivity and specificity of fat-suppressed fast low-angle shot (FLASH) 3D MR imaging in the detection of patellar cartilage surface lesions in comparison with CT arthrography. Fifty patients, with or without symptoms of chondromalacia, were prospectively examined by CT arthrography and fat-suppressed 3D gradient-echo MR imaging. All MR examinations were evaluated by three observers, two of them reaching a consensus interpretation. The lesions were graded according to their morphology and their extent. The CT arthrography was considered as the reference examination. For both sets of observers, the final diagnosis of chondromalacia was obtained in 92.5 %. The specificity was 60 % on a patient-by-patient basis. Fissures were missed in 83 and 60 %, respectively, but were isolated findings only in 2.5 % of the cases. Considering ulcers involving more than 50 % of the cartilage thickness, 65 and 88 %, respectively, were recognized. Fat-suppressed FLASH 3D is an adequate pulse sequence for the detection of patellar cartilage ulcers. It can be applied on a routine clinical basis, but it does not show as many fissures as CT arthrography and is less precise for grading of lesions. (orig.)

  5. Evaluation of patellar cartilage surface lesions: comparison of CT arthrography and fat-suppressed FLASH 3D MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Daenen, B.R.; Ferrara, M.A.; Marcelis, S.; Dondelinger, R.F. [Department of Medical Imaging, University Hospital Sart-Tilman, Liege (Belgium)

    1998-07-01

    The aim of this study was to evaluate the sensitivity and specificity of fat-suppressed fast low-angle shot (FLASH) 3D MR imaging in the detection of patellar cartilage surface lesions in comparison with CT arthrography. Fifty patients, with or without symptoms of chondromalacia, were prospectively examined by CT arthrography and fat-suppressed 3D gradient-echo MR imaging. All MR examinations were evaluated by three observers, two of them reaching a consensus interpretation. The lesions were graded according to their morphology and their extent. The CT arthrography was considered as the reference examination. For both sets of observers, the final diagnosis of chondromalacia was obtained in 92.5 %. The specificity was 60 % on a patient-by-patient basis. Fissures were missed in 83 and 60 %, respectively, but were isolated findings only in 2.5 % of the cases. Considering ulcers involving more than 50 % of the cartilage thickness, 65 and 88 %, respectively, were recognized. Fat-suppressed FLASH 3D is an adequate pulse sequence for the detection of patellar cartilage ulcers. It can be applied on a routine clinical basis, but it does not show as many fissures as CT arthrography and is less precise for grading of lesions. (orig.) With 4 figs., 3 tabs., 21 refs.

  6. Clinical arthrography

    International Nuclear Information System (INIS)

    Arndt, R.; Horns, J.W.; Gold, R.H.; Blaschke, D.D.

    1985-01-01

    This book deals with the method and interpretation of arthrography of the shoulder, knee, ankle, elbow, hip, wrist, and metacarpophalangeal, interphalangeal, and temporomandibular joints. The emphasis is on orthopaedic disorders, usually of traumatic origin, which is in keeping with the application of arthrography in clinical practice. Other conditions, such as inflammatory and degenerative diseases, congenital disorders and, in the case of the hip, arthrography of reconstructive joint surgery, are included. Each chapter is devoted to one joint and provides a comprehensive discussion on the method of arthrography, including single and double contrast techniques where applicable, normal radiographic anatomy, and finally, the interpretation of the normal and the abnormal arthrogram

  7. Comparison of conventional MRI and MR arthrography in the evaluation of wrist ligament tears: A preliminary experience

    Science.gov (United States)

    Pahwa, Shivani; Srivastava, Deep N; Sharma, Raju; Gamanagatti, Shivanand; Kotwal, Prakash P; Sharma, Vijay

    2014-01-01

    Aims: To compare conventional magnetic resonance imaging (MRI) and direct magnetic resonance (MR) arthrography in the evaluation of triangular fibrocartilage complex (TFCC) and intrinsic wrist ligament tears. Materials and Methods: T1-weighted, fat suppressed (FS) proton density plus T2-weighted (FS PD/T2), 3D multiple-echo data image combination (MEDIC) sequences and direct MR arthrography were performed in 53 patients with wrist pain. Images were evaluated for the presence and location of TFCC, scapholunate ligament (SLL) and lunatotriquetral ligament (LTL) tears, and imaging findings were compared with operative findings in 16 patients who underwent arthroscopy or open surgery (gold standard). Results: Sixteen patients underwent arthroscopy/open surgery: 12 TFCC tears were detected arthroscopically out of which 9 were detected on FS PD/T2 sequence, 10 on MEDIC sequence, and all 12 were detected on MR arthrography. The sensitivities of FS PD/T2, MEDIC sequences, and MR arthrography in the detection of TFCC tears were 75%, 83.3%, and 100%, respectively. Out of the eight arthroscopically confirmed SLL tears, three tears were detected on FS PD/T2 sequence, five on MEDIC sequence, and all eight were visualized on MR arthrography. The sensitivities of FS PD/T2, MEDIC sequences, and MR arthrography in detecting SLL tears were 37.5%, 62.5%, and 100%, respectively. One arthroscopically confirmed LTL tear was diagnosed on FS PD/T2 sequence, three on MEDIC sequence, and all five arthroscopically confirmed LTL tears were detected with MR arthrography. The sensitivities of PD, MEDIC sequences, and MR arthrography in detecting LTL tears were 20%, 40%, and 100%, respectively. Conclusions: MR arthrography is the most sensitive and specific imaging modality for the evaluation of wrist ligament tears. PMID:25114389

  8. Comparison of conventional MRI and MR arthrography in the evaluation of wrist ligament tears: A preliminary experience

    Directory of Open Access Journals (Sweden)

    Shivani Pahwa

    2014-01-01

    Full Text Available Aims: To compare conventional magnetic resonance imaging (MRI and direct magnetic resonance (MR arthrography in the evaluation of triangular fibrocartilage complex (TFCC and intrinsic wrist ligament tears. Materials and Methods: T1-weighted, fat suppressed (FS proton density plus T2-weighted (FS PD/T2, 3D multiple-echo data image combination (MEDIC sequences and direct MR arthrography were performed in 53 patients with wrist pain. Images were evaluated for the presence and location of TFCC, scapholunate ligament (SLL and lunatotriquetral ligament (LTL tears, and imaging findings were compared with operative findings in 16 patients who underwent arthroscopy or open surgery (gold standard. Results: Sixteen patients underwent arthroscopy/open surgery: 12 TFCC tears were detected arthroscopically out of which 9 were detected on FS PD/T2 sequence, 10 on MEDIC sequence, and all 12 were detected on MR arthrography. The sensitivities of FS PD/T2, MEDIC sequences, and MR arthrography in the detection of TFCC tears were 75%, 83.3%, and 100%, respectively. Out of the eight arthroscopically confirmed SLL tears, three tears were detected on FS PD/T2 sequence, five on MEDIC sequence, and all eight were visualized on MR arthrography. The sensitivities of FS PD/T2, MEDIC sequences, and MR arthrography in detecting SLL tears were 37.5%, 62.5%, and 100%, respectively. One arthroscopically confirmed LTL tear was diagnosed on FS PD/T2 sequence, three on MEDIC sequence, and all five arthroscopically confirmed LTL tears were detected with MR arthrography. The sensitivities of PD, MEDIC sequences, and MR arthrography in detecting LTL tears were 20%, 40%, and 100%, respectively. Conclusions: MR arthrography is the most sensitive and specific imaging modality for the evaluation of wrist ligament tears.

  9. A comparison of MRI and wrist arthrography in the diagnosis of TFC injury

    Energy Technology Data Exchange (ETDEWEB)

    Shionoya, Kaori; Nakamura, Ryogo; Imaeda, Toshihiko [Nagoya Univ., Aichi (Japan). Branch Hospital; Tsunoda, Kenji; Makino, Naoki

    1995-08-01

    The present study compared the diagnostic usefulness of magnetic resonance imaging (MRI) and wrist arthrography in triangular fibrocartilage (TFC) injuries. The subjects were 102 wrists with arthroscopically confirmed presence or absence of TFC perforation. TFC perforation was present in 35 and 47 wrists and absent in the other 67 and 55 wrists on arthrography and MRI, respectively. Using arthroscopy as the reference standard, arthrography for the detection of TFC perforation had a sensitivity of 85% and a specificity of 100%. All 6 false negative cases on arthrography had scarring adhesions of the TFC in the wrist. On the other hand, the sensitivity and specificity of MRI were 73% and 72%, respectively. An accuracy was 94% for arthrography and 73% for MRI. It was difficult to detect qualitative TFC injury and the presence or absence of TFC perforation on MRI. Arthrography is thus superior to MRI in both sensitivity and specificity. The complementary use of arthrography and MRI is considered to increase the diagnostic accuracy. (S.Y.).

  10. Magnetic resonance arthrography in chronic wrist pain. Artografia con Risonanza Magnetica (arto-RM) nelle malattie dolorose croniche del polso

    Energy Technology Data Exchange (ETDEWEB)

    Valeri, G.; Ferrara, C. (Ancona Univ. (Italy). Cattedra di Radiologia); Carloni, S. (Ancona Univ. (Italy). Cattedra di Ortopedia) (and others)

    The purpose of this paper is to investigate the clinical role of Magnetic Resonance Arthrography (MRA) of the wrist in subjects with chronic pain. Thirty-five patients complaining of wrist pain for more than 6 months were submitted to MRI an MRA. All patients received and intra-articular injection of 2-10 mL of a 10 mmol saline solution of Gd-DPTA. The overall diagnostic accuracy rates of MRI and MRA were 40% and 81% respectively, with sensitivity and specificity of 63% and 39% (MRI) and of 82% and 79% (MRA). The conclusion is that compared with MRI, MRA can be considered a useful tool for the visualization of interosseus carpal ligaments and of the triangular fibrocartilage complex. MRA also helps detect injuries in these structures.

  11. Rotator cuff tears noncontrast MRI compared to MR arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ji Hyun; Yoon, Young Cheol [Sungkyunkwan University, School of Medicine, Department of Radiology, Samsung Medical Center, Gangnam-gu, Seoul (Korea, Republic of); Jung, Jee Young [Chungang University School of Medicine, Department of Radiology, Chungang University Hospital, Seoul (Korea, Republic of); Yoo, Jae Chul [Sungkyunkwan University, School of Medicine, Department of Orthopedic Surgery, Samsung Medical Center, Seoul (Korea, Republic of)

    2015-12-15

    To compare the accuracy of indirect magnetic resonance arthrography and noncontrast magnetic resonance imaging for diagnosing rotator cuff tears. In total, 333 patients who underwent noncontrast magnetic resonance imaging or indirect magnetic resonance arthrography were included retrospectively. Two musculoskeletal radiologists evaluated the images for the presence of supraspinatus-infraspinatus and subscapularis tendon tears. The overall diagnostic performance was calculated using the arthroscopic findings as the reference standard. Statistical differences between the diagnostic performances of the two methods were analyzed. Ninety-six and 237 patients who underwent noncontrast magnetic resonance imaging and indirect magnetic resonance arthrography were assigned into groups A and B, respectively. Sensitivity for diagnosing articular-surface partial-thickness supraspinatus-infraspinatus tendon tear was slightly higher in group B than in group A. Statistical significance was confirmed by multivariate analysis using the generalized estimating equation (p = 0.046). The specificity for diagnosing subscapularis tendon tear (85 % vs. 68 %, p = 0.012) and grading accuracy (57 % vs. 40 %, p = 0.005) was higher in group B than in group A; the differences were statistically significant for one out of two readers. Univariate analysis using the generalized estimating equation showed that the accuracy for diagnosing subscapularis tendon tear in group B was higher than in group A (p = 0.042). There were no statistically significant differences between the diagnostic performances of both methods for any other parameters. Indirect magnetic resonance arthrography may facilitate more accurate diagnosis and grading of subscapularis tendon tears compared with noncontrast magnetic resonance imaging. (orig.)

  12. Rotator cuff tears noncontrast MRI compared to MR arthrography

    International Nuclear Information System (INIS)

    Lee, Ji Hyun; Yoon, Young Cheol; Jung, Jee Young; Yoo, Jae Chul

    2015-01-01

    To compare the accuracy of indirect magnetic resonance arthrography and noncontrast magnetic resonance imaging for diagnosing rotator cuff tears. In total, 333 patients who underwent noncontrast magnetic resonance imaging or indirect magnetic resonance arthrography were included retrospectively. Two musculoskeletal radiologists evaluated the images for the presence of supraspinatus-infraspinatus and subscapularis tendon tears. The overall diagnostic performance was calculated using the arthroscopic findings as the reference standard. Statistical differences between the diagnostic performances of the two methods were analyzed. Ninety-six and 237 patients who underwent noncontrast magnetic resonance imaging and indirect magnetic resonance arthrography were assigned into groups A and B, respectively. Sensitivity for diagnosing articular-surface partial-thickness supraspinatus-infraspinatus tendon tear was slightly higher in group B than in group A. Statistical significance was confirmed by multivariate analysis using the generalized estimating equation (p = 0.046). The specificity for diagnosing subscapularis tendon tear (85 % vs. 68 %, p = 0.012) and grading accuracy (57 % vs. 40 %, p = 0.005) was higher in group B than in group A; the differences were statistically significant for one out of two readers. Univariate analysis using the generalized estimating equation showed that the accuracy for diagnosing subscapularis tendon tear in group B was higher than in group A (p = 0.042). There were no statistically significant differences between the diagnostic performances of both methods for any other parameters. Indirect magnetic resonance arthrography may facilitate more accurate diagnosis and grading of subscapularis tendon tears compared with noncontrast magnetic resonance imaging. (orig.)

  13. MR imaging of the shoulder: Spectrum of abnormalities in 65 patients and correlation with arthrography and surgery

    International Nuclear Information System (INIS)

    Zlatkin, M.B.; Reicher, M.A.; Kellerhouse, L.E.; Resnick, D.; Sartoris, D.J.

    1987-01-01

    MR imaging has previously been used to demonstrate the appearance of the normal shoulder. In this investigation the authors employed MR imaging in 65 consecutive patients with shoulder pain. Subsequent arthrography was performed in 31 patients and surgery in 15. Clinical follow-up was obtained in 35 patients treated conservatively. MR imaging was highly accurate in depicting the spectrum of rotator cuff abnormalities associated with mechanical impingment, including both large and small rotator cuff tears as well as tendinitis. Abnormalities of the capsular mechanisms, osseous tumors, ostenonecrosis, and injuries to the supporting musculature were also well depicted. Considerable potential exists for MR imaging in evaluating shoulder joint disease

  14. Cardiac magnetic resonance imaging

    African Journals Online (AJOL)

    2011-03-06

    Mar 6, 2011 ... Cardiac magnetic resonance imaging. Cardiovascular magnetic resonance imaging is becoming a routine diagnostic technique. BRUCE s sPOTTiswOOdE, PhD. MRC/UCT Medical Imaging Research Unit, University of Cape Town, and Division of Radiology, Stellenbosch University. Bruce Spottiswoode ...

  15. MR imaging of hyaline cartilage in chondromalacia patellae and osteochondrosis dissecans: A comparison with CT-arthrography and arthroscopy

    International Nuclear Information System (INIS)

    Lehner, K.; Heuck, A.; Lukas, P.; Rodammer, G.; Allgayer, B.; Pasquay, E.

    1987-01-01

    Superior to spin-echo sequences, the articular hyaline cartilage was imaged with fast-field-echo sequences (FFE, Gyroscan 0.5-T, Philips) with an excitation pulse angle of 40 0 to 60 0 . Chondromalaceous lesions could be demonstrated in 30 patients with chondropathia patellae with the same sensitivity compared with CT arthrography. In a further 50 patients with osteochondrosis dissecans, discontinuities of the cartilage could be predicted using the deeply invading articular fluid as an indicator. The sensitivity of MR imaging, as controlled by arthroscopy, was very high in that respect. Separate from the nonhemorrhagic articular fluid, the cartilaginous defects could be imaged directly by variation of the FFE parameters

  16. Magnetic resonance imaging apparatus

    International Nuclear Information System (INIS)

    Ehnholm, G.J.

    1991-01-01

    This patent describes an electron spin resonance enhanced magnetic resonance (MR) imaging (ESREMRI) apparatus able to generate a primary magnetic field during periods of nuclear spin transition excitation and magnetic resonance signal detection. This allows the generation of ESREMRI images of a subject. A primary magnetic field of a second and higher value generated during periods of nuclear spin transition excitation and magnetic resonance signal detection can be used to generate conventional MR images of a subject. The ESREMRI and native MR images so generated may be combined, (or superimposed). (author)

  17. MRI and arthrography in the evaluation of TMJ disorders

    International Nuclear Information System (INIS)

    Nakasato, Tatsuhiko; Ehara, Shigeru; Tamakawa, Yoshiharu; Kobayakawa, Takafumi.

    1991-01-01

    Arthrosis of the temporomandibular joint (TMJ) is a noninfectious, noninflammatory condition characterized by joint pain, noise (clicking) and abnormal motion. It contains various disease processes, such as abnormalities in the menisci or masticating muscles, subluxation of the condyle and degenerative joint disease. Analysis of the morphology and dynamics of TMJ by means of imaging modalities has become highly advanced since the development of arthrography in the late 1970s. Magnetic resonance imaging (MRI) has become the modality of choice in the evaluation of TMJ owing to the development of surface coils. We retrospectively studied MRI and inferior joint compartment arthrography in the evaluation of TMJ disorders. Nineteen joints of 14 patients included 15 with internal derangement, two with osteoarthrosis and two normal joints. Sagittal MR images were routinely obtained in a resting position and in positions with the mouth half open, and also with the mouth fully open on balanced images. Although perforation of the menisci was difficult to evaluate, MRI and arthrography were equally useful in identifying the shape and position of the meniscus. However, MRI was more reliable in depicting TMJ abnormalities than arthrography. MRI is considered to be the modality of choice in screening arthrosis of TMJ, making the definitive diagnosis of internal derangement and monitoring conservative therapy for arthrosis. (author)

  18. MRI and arthrography in the evaluation of TMJ disorders

    Energy Technology Data Exchange (ETDEWEB)

    Nakasato, Tatsuhiko; Ehara, Shigeru; Tamakawa, Yoshiharu (Iwate Medical Univ., Morioka (Japan). School of Medicine); Kobayakawa, Takafumi

    1991-08-01

    Arthrosis of the temporomandibular joint (TMJ) is a noninfectious, noninflammatory condition characterized by joint pain, noise (clicking) and abnormal motion. It contains various disease processes, such as abnormalities in the menisci or masticating muscles, subluxation of the condyle and degenerative joint disease. Analysis of the morphology and dynamics of TMJ by means of imaging modalities has become highly advanced since the development of arthrography in the late 1970s. Magnetic resonance imaging (MRI) has become the modality of choice in the evaluation of TMJ owing to the development of surface coils. We retrospectively studied MRI and inferior joint compartment arthrography in the evaluation of TMJ disorders. Nineteen joints of 14 patients included 15 with internal derangement, two with osteoarthrosis and two normal joints. Sagittal MR images were routinely obtained in a resting position and in positions with the mouth half open, and also with the mouth fully open on balanced images. Although perforation of the menisci was difficult to evaluate, MRI and arthrography were equally useful in identifying the shape and position of the meniscus. However, MRI was more reliable in depicting TMJ abnormalities than arthrography. MRI is considered to be the modality of choice in screening arthrosis of TMJ, making the definitive diagnosis of internal derangement and monitoring conservative therapy for arthrosis. (author).

  19. Comparison between 3D isotropic and 2D conventional MR arthrography for diagnosing rotator cuff tear and labral lesions: A meta-analysis.

    Science.gov (United States)

    Lee, Sun Hwa; Yun, Seong Jong; Jin, Wook; Park, So Young; Park, Ji Seon; Ryu, Kyung Nam

    2018-03-30

    lesions. 3D-isotropic MR arthrography can replace 2D-conventional MR arthrography. 3D-isotropic MR arthrography using TSE sequence is recommended for more accurate diagnosis, as it demonstrates increased sensitivity. 2 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.

  20. Magnetic resonance imaging (MRI

    Directory of Open Access Journals (Sweden)

    Takavar A

    1993-04-01

    Full Text Available Basic physical principles of nuclear magnetic resonance imaging (N.M.R.I, a nonionizing medical imaging technique, are described. Principles of NMRI with other conventional imaging methods, ie, isotope scanning, ultrasonography and radiography have been compared. T1 and T2 and spin density (S.D. factors and different image construction techniques based on their different combinations is discussed and at the end physical properties of some N.M.R images is mentioned.

  1. Magnetic resonance imaging (MRI)

    OpenAIRE

    Takavar A

    1993-01-01

    Basic physical principles of nuclear magnetic resonance imaging (N.M.R.I), a nonionizing medical imaging technique, are described. Principles of NMRI with other conventional imaging methods, ie, isotope scanning, ultrasonography and radiography have been compared. T1 and T2 and spin density (S.D.) factors and different image construction techniques based on their different combinations is discussed and at the end physical properties of some N.M.R images is mentioned.

  2. The diagnostic value of magnetic resonance arthrography of the shoulder in detection and grading of SLAP lesions: Comparison with arthroscopic findings

    International Nuclear Information System (INIS)

    Amin, Mohammed Farghally; Youssef, Ahmed Omar

    2012-01-01

    Purpose: The purpose of the study is to determine the usefulness of magnetic resonance arthrography (MRA) in diagnosis and grading of superior labrum anterior to posterior (SLAP) lesions of the Glenoid Labrum Compared with surgery Material and methods: This was a prospective study including fifty nine clinically diagnosed SLAP patients. The study was done during the period from January 2008 to June 2010. All patients were submitted to history taking, clinical examination and conventional MRI examination of the shoulder, MRA was done in patients with negative conventional MRI, all of these patients underwent arthroscopy for diagnosis wither open or arthroscopy for diagnosis and treatment and results were compared with MRA findings. Main outcome measures: Sensitivity, specificity, positive and negative predictive values, and overall accuracy of MR arthrography in detection and grading of SLAP lesions of the gelnoid labrum. Results: Out of fifty nine patients, 25 patients had positive MR findings in conventional MRI, and 34 patients had negative MR findings, who underwent MR arthrography; 10 out of them had normal arthrogram (only 6 of them underwent arthroscopy), 22 had SLAP (superior labrum anterior to posterior) lesions, one had Bankart's lesion and one had internal impingement syndrome. These results were compared with arthroscopy results. The overall sensitivity of MRA in detection of SLAP lesions was 90% while the specificity was 50%, negative predictive value (NPV) was 66.6% and positive predicative value (PPV) was 81.8%. MRA and arthroscopy results were concurrent in 79.3% patients. Conclusion: MR arthrography is a sensitive minimally invasive technique for detection and grading of SLAP lesions, it can help in avoiding patients unnecessary diagnostic arthroscopy

  3. The diagnostic value of magnetic resonance arthrography of the shoulder in detection and grading of SLAP lesions: Comparison with arthroscopic findings

    Energy Technology Data Exchange (ETDEWEB)

    Amin, Mohammed Farghally, E-mail: Mohammed_amin37@yahoo.com [Department of Radiodiagnosis ElMinya University, ElMinya High Road, ElMinya (Egypt); Youssef, Ahmed Omar [Department of Orthropedic Surgery El Minya University, ElMinya (Egypt)

    2012-09-15

    Purpose: The purpose of the study is to determine the usefulness of magnetic resonance arthrography (MRA) in diagnosis and grading of superior labrum anterior to posterior (SLAP) lesions of the Glenoid Labrum Compared with surgery Material and methods: This was a prospective study including fifty nine clinically diagnosed SLAP patients. The study was done during the period from January 2008 to June 2010. All patients were submitted to history taking, clinical examination and conventional MRI examination of the shoulder, MRA was done in patients with negative conventional MRI, all of these patients underwent arthroscopy for diagnosis wither open or arthroscopy for diagnosis and treatment and results were compared with MRA findings. Main outcome measures: Sensitivity, specificity, positive and negative predictive values, and overall accuracy of MR arthrography in detection and grading of SLAP lesions of the gelnoid labrum. Results: Out of fifty nine patients, 25 patients had positive MR findings in conventional MRI, and 34 patients had negative MR findings, who underwent MR arthrography; 10 out of them had normal arthrogram (only 6 of them underwent arthroscopy), 22 had SLAP (superior labrum anterior to posterior) lesions, one had Bankart's lesion and one had internal impingement syndrome. These results were compared with arthroscopy results. The overall sensitivity of MRA in detection of SLAP lesions was 90% while the specificity was 50%, negative predictive value (NPV) was 66.6% and positive predicative value (PPV) was 81.8%. MRA and arthroscopy results were concurrent in 79.3% patients. Conclusion: MR arthrography is a sensitive minimally invasive technique for detection and grading of SLAP lesions, it can help in avoiding patients unnecessary diagnostic arthroscopy.

  4. High-resolution magnetic resonance imaging of rotator cuff tears using a microscopy coil. Noninvasive detection without intraarticular contrast material

    International Nuclear Information System (INIS)

    Hitachi, Shin; Takase, Kei; Higano, Shuichi; Takahashi, Shoki; Tanaka, Minoru; Tojo, Yuichi; Tabata, Shiro; Majima, Kazuhiro

    2011-01-01

    The aim of this study was to evaluate the feasibility of high-resolution magnetic resonance imaging (MRI) using a microscopy coil for the diagnosis of rotator cuff tears by comparing the method to conventional MRI and MRI arthrography. A total of 68 shoulders were prospectively studied using a 1.5-T MRI unit. Conventional MRI scans were obtained with a surface coil and high-resolution MRI scans with a microscopy coil. MRI arthrography was performed in 28 shoulders using a surface coil. MRI evaluation of tears of rotator cuff tendons was compared with arthroscopic findings and surgical results. The surgery revealed 40 full-thickness tears, 13 partial-thickness tears, and 15 intact cuffs. In all, 35 (88%) full-thickness tears were correctly diagnosed on conventional MRI and 40 (100%) on high-resolution MRI. MR arthrography delineated 11 of 12 (92%) full-thickness tears. Altogether, 5 (38%) of the partial-thickness tears were detected on conventional MRI, and 12 (92%) were clearly demonstrated on high-resolution MRI. MRI arthrography depicted three (60%) of five partial-thickness tears. High-resolution MRI showed higher sensitivity than conventional MRI (P<0.05) and had values equivalent to those of MRI arthrography for diagnosing partial-thickness tears. High-resolution MRI with a microscopy coil is a feasible, noninvasive technique for diagnosing rotator cuff tears. (author)

  5. Magnetic resonance imaging

    International Nuclear Information System (INIS)

    Robertson, Angus

    1990-01-01

    An assessment is made of the clinical benefits of expensive diagnostic technology, such as the magnetic resonance imaging. It is concluded that to most radiologists, magnetic resonance imaging has a definite place in the diagnostic scenario, especially for demonstrating central nervous system lesions in multiple sclerosis. While it is recognized that medical and financial resources are limited, it is emphasised that the cost to society must be balanced against the patient benefit. 17 refs

  6. Imaging by magnetic resonance

    International Nuclear Information System (INIS)

    Duroure, J.F.; Serpolay, H.; Vallens, D.

    1995-01-01

    Here are described the advanced technology for nuclear magnetic resonance imaging: reduction of acquisition times, and rebuilding times, images quality improvement. The tendency is to open the machines at low and middle field, on a market being at 10% of NMR I sales, with economical, scientifical and ergonomic reasons broadly developed by constructors

  7. Functional Magnetic Resonance Imaging

    Science.gov (United States)

    Voos, Avery; Pelphrey, Kevin

    2013-01-01

    Functional magnetic resonance imaging (fMRI), with its excellent spatial resolution and ability to visualize networks of neuroanatomical structures involved in complex information processing, has become the dominant technique for the study of brain function and its development. The accessibility of in-vivo pediatric brain-imaging techniques…

  8. Detection of partial-thickness supraspinatus tendon tears: is a single direct MR arthrography series in ABER position as accurate as conventional MR arthrography?

    International Nuclear Information System (INIS)

    Schreinemachers, Saskia A.; Hulst, Victor P.M. van der; Woude, Henk-Jan van der; Willems, W.J.; Bipat, Shandra

    2009-01-01

    The purpose of this study was to retrospectively evaluate sensitivity and specificity of a single magnetic resonance (MR) arthrography series in abduction external rotation (ABER) position compared with conventional MR arthrography for detection of supraspinatus tendon tears, with arthroscopy as gold standard, and to assess interobserver variability. Institutional review board approval was obtained; informed consent was waived. MR arthrograms of 250 patients (170 men and 80 women; mean age, 36 years) were retrospectively and independently evaluated by three observers. Oblique coronal T1-weighted fat-suppressed images, proton density, and T2-weighted images and axial T1-weighted images and oblique sagittal T1-weighted fat-suppressed images were analyzed to detect supraspinatus tendon tears. Separately, a single T1-weighted fat-suppressed oblique axial series in ABER position was evaluated. Both protocols were scored randomly without knowledge of patients' clinical history and arthroscopy results. Tears were subclassified, based on articular surface integrity and extension (Lee classification). Interobserver agreement was assessed by kappa statistics for all patients. Ninety-two of 250 patients underwent arthroscopy; sensitivity and specificity of ABER and conventional MR arthrography were calculated and compared using paired McNemar test. Weighted kappa values of ABER and conventional MR arthrography were 0.48-0.65 and 0.60-0.67, respectively. According to arthroscopy, 69 of 92 patients had an intact cuff, and 23 patients had a cuff tear (16 partial thickness and seven full thickness). There were no statistically significant differences between ABER and conventional MR arthrography regarding sensitivity (48-61% and 52-70%, respectively) and specificity (80-94% and 91-95%). Sensitivity and specificity of a single T1-weighted series in ABER position and conventional MR arthrography are comparable for assessment of rotator cuff tears. (orig.)

  9. Detection of partial-thickness supraspinatus tendon tears: is a single direct MR arthrography series in ABER position as accurate as conventional MR arthrography?

    Energy Technology Data Exchange (ETDEWEB)

    Schreinemachers, Saskia A. [Onze Lieve Vrouwe Gasthuis, Department of Radiology, Amsterdam (Netherlands); Onze Lieve Vrouwe Gasthuis, Amsterdam (Netherlands); Hulst, Victor P.M. van der; Woude, Henk-Jan van der [Onze Lieve Vrouwe Gasthuis, Department of Radiology, Amsterdam (Netherlands); Willems, W.J. [Onze Lieve Vrouwe Gasthuis, Orthopaedic Surgery, Amsterdam (Netherlands); Bipat, Shandra [University of Amsterdam (NL). Department of Radiology, Academic Medical Center (Netherlands)

    2009-10-15

    The purpose of this study was to retrospectively evaluate sensitivity and specificity of a single magnetic resonance (MR) arthrography series in abduction external rotation (ABER) position compared with conventional MR arthrography for detection of supraspinatus tendon tears, with arthroscopy as gold standard, and to assess interobserver variability. Institutional review board approval was obtained; informed consent was waived. MR arthrograms of 250 patients (170 men and 80 women; mean age, 36 years) were retrospectively and independently evaluated by three observers. Oblique coronal T1-weighted fat-suppressed images, proton density, and T2-weighted images and axial T1-weighted images and oblique sagittal T1-weighted fat-suppressed images were analyzed to detect supraspinatus tendon tears. Separately, a single T1-weighted fat-suppressed oblique axial series in ABER position was evaluated. Both protocols were scored randomly without knowledge of patients' clinical history and arthroscopy results. Tears were subclassified, based on articular surface integrity and extension (Lee classification). Interobserver agreement was assessed by kappa statistics for all patients. Ninety-two of 250 patients underwent arthroscopy; sensitivity and specificity of ABER and conventional MR arthrography were calculated and compared using paired McNemar test. Weighted kappa values of ABER and conventional MR arthrography were 0.48-0.65 and 0.60-0.67, respectively. According to arthroscopy, 69 of 92 patients had an intact cuff, and 23 patients had a cuff tear (16 partial thickness and seven full thickness). There were no statistically significant differences between ABER and conventional MR arthrography regarding sensitivity (48-61% and 52-70%, respectively) and specificity (80-94% and 91-95%). Sensitivity and specificity of a single T1-weighted series in ABER position and conventional MR arthrography are comparable for assessment of rotator cuff tears. (orig.)

  10. Magnetic resonance imaging of the shoulder

    International Nuclear Information System (INIS)

    Ilieva, E.

    2015-01-01

    Full text: Magnetic resonance imaging (MRI) is an excellent non-invasive imaging tool that can complement the physical examination in the evaluation of traumatic and non-traumatic injuries of the shoulder. The superb soft tissue contrast and multiplanar capabilities of MRI make it a preferred modality to provide a global assessment of the soft tissue and osseous structures of the shoulder. Learning objectives: to review briefly the anatomy of the shoulder and the specificity of sequences and planes for MRI; to demonstrate the characteristic MR findings of some of the most common shoulder disorders; to indicate how MR arthrography (MRA) of the shoulder can add extra value to the diagnostic process; to outline a systematic approach to the interpretation of the shoulder MR examination. Choosing the most suitable sequences and planes as well as the thorough knowledge of the anatomic structures assist the correct diagnosis of the pathologic disorders of the shoulder which is of great importance for the precise treatment management, surgical versus conservative, as well as for the appropriate surgical approach, open versus arthroscopic

  11. Nuclear magnetic resonance imaging

    International Nuclear Information System (INIS)

    Young, I.R.

    1984-01-01

    In a method of imaging a body in which nuclear magnetic resonance is excited in a region including part of the body, and the free induction decay signal is measured, a known quantity of a material of known nuclear magnetic resonance properties, for example a bag of water, is included in the region so as to enhance the measured free induction decay signal. This then reduces the generation of noise during subsequent processing of the signal. (author)

  12. Magnetic resonance imaging of the shoulder: a review of potential sources of diagnostic errors

    International Nuclear Information System (INIS)

    Carroll, K.W.; Helms, C.A.

    2002-01-01

    Shoulder magnetic resonance (MR) imaging and MR arthrography are frequently utilized in the evaluation of shoulder pain and instability. The clinical scenario and imaging findings may be confusing to clinicians and radiologists and may present diagnostic challenges for those involved in evaluating and treating shoulder pathology. Often rotator cuff and labral abnormalities may be coexistent, clinical manifestations of denervation syndromes may be confusing to clinicians, and normal anatomic variations, imaging pitfalls, and various artifacts may cause dilemmas for the radiologist. This article will review the most frequently encountered mimickers and pitfalls of MR imaging of the shoulder. (orig.)

  13. Incidence of greater trochanteric pain syndrome in patients suspected for femoroacetabular impingement evaluated using magnetic resonance arthrography of the hip.

    Science.gov (United States)

    Pozzi, Grazia; Lanza, Ezio; Parra, Cleber Garcia; Merli, Ilaria; Sconfienza, Luca Maria; Zerbi, Alberto

    2017-03-01

    We evaluated the incidence of greater trochanter pain syndrome (GTPS) in patients who underwent magnetic resonance arthrography (MRA) of the hip for a suspected femoroacetabular impingement (FAI) syndrome. Hip MRA performed at our institution (3/2012-1/2014) were reviewed. The absence/presence of FAI (cam, pincer, and mixed) was noted. GTPS diagnosis was based on gluteus medius/minimus tendinopathy/tears, trochanteric bursitis, fascia lata thickening, and trochanter bone oedema/erosion. Subgroup analysis for age (under/over 40 years) and FAI type (cam, pincer, and mixed) was also performed. N = 189 patients were included (n = 125 males; age 39 ± 12 years). FAI was diagnosed in n = 133 (70, 4%): cam type, n = 85 (63, 9%); pincer type, n = 22 (16, 6%); and mixed type, n = 26 (19, 5%). N = 72 patients (38.1%) had tendinopathy, n = 14 (7.4%) had trochanter erosion, n = 31 (16.4%) had bursitis, n = 4 had bone oedema (2.1%), and n = 3 (1.6%) had fascia lata thickening, resulting in GTPS diagnosis in n = 74 patients (39.2%). The association of normal hip morphology/GTPS was significantly higher (P = 0.023) than that of FAI/GTPS. Under 40 years, GTPS incidence was higher in patients with normal hip and pincer-type FAI (P = 0.028). Over 40 years, no difference between patients with/without FAI (P = 0.119) was seen. GTPS was more frequently observed in patients with normal hip morphology than in patients with FAI, particularly in patients under 40.

  14. Magnetic resonance imaging

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    Magnetic resonance imaging (MRI) is a new and innovative technique that affords anatomic images in multiple planes and that may provide information about tissue characterization. The magnetic resonance images are obtained by placing the patient or the area of interest within a powerful, highly uniform, static magnetic field. Magnetized protons (hydrogen nuclei) within the patient align like small magnets in this field. Radiofrequency pulses are then used to create an oscillating magnetic field perpendicular to the main field. Magnetic resonance images differ from those produced by x-rays: the latter are associated with absorption of x-ray energy while magnetic resonance images are based on proton density and proton relaxation dynamics. Proton characteristics vary according to the tissue under examination and reflect its physical and chemical properties. To resolve issues regarding safety and efficacy, the Warren Grant Magnuson Clinical Center and the Office of Medical Applications of Research of the National Institutes of Health (NIH) convened a consensus conference about MRI Oct 26 through 28, 1987. At the NIH, the Consensus Development Conference brings together investigators in the biomedical sciences, clinical investigators, practicing physicians, and consumer and special interest groups to make a scientific assessment of technologies, including drugs, devices, and procedures, and to seek agreement on their safety and effectiveness

  15. MR-imaging of anterior tibiotalar impingement syndrome: Agreement, sensitivity and specificity of MR-imaging and indirect MR-arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Haller, Joerg [Department of Radiology, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Ludwig Boltzmann Institute for Osteology, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Bernt, Reinhard [Department of Radiology, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria)]. E-mail: reinhard.bernt@wgkk.sozvers.at; Seeger, Thomas [Department of Trauma Surgery, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Weissenbaeck, Alexander [Department of Trauma Surgery, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Tuechler, Heinrich [Ludwig Boltzmann Institute for Hematology, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Resnick, Donald [Department of Radiology, VA Medical Center, UCSD, 3350 La Jolla Village Dr, San Diego, CA 92161 (United States)

    2006-06-15

    Objective: To clarify the role of MR-imaging in the diagnosis of anterior ankle impingement syndromes. Materials and methods: We prospectively examined 51 consecutive patients with chronic ankle pain by MR-imaging. Arthroscopy was performed in 29 patients who previously underwent non-enhanced MR-imaging; in 11 patients, indirect MR-arthrography additionally was performed. MR-examinations were correlated with clinical findings; MR and arthroscopy scores were statistically compared, agreement was measured. Results: Arthroscopy demonstrated granulation tissue in the lateral gutter (38%) and anterior recess (31%), lesions of the anterior tibiofibular (31%) and the anterior talofibular ligament (21%) as well as intraarticular bodies (10%). Stenosing tenosynovitis and a ganglionic cyst were revealed as extraarticular causes for chronic ankle pain by MR-examination (17%). Agreement of MR-imaging and arthroscopy was fair for the anterior talofibular ligament and the anterior joint cavity (kappa 0.40). Major discrepancy was found for non-enhanced MR scans (kappa 0.49) when compared with indirect MR-arthrography (kappa 0.03) in the anterior cavity. The sensitivity for lesions of the anterior talofibular and calcaneofibular ligament and the anterior cavity (0.91-0.87) detected by MR-imaging was superior in comparison to lesions of the anterior tibiofibular ligament and anteromedial cavity (0.50-0.24). Conclusion: MR-imaging provides additional information about the mechanics of chronic ankle impingement rather than an accurate diagnosis of this clinical entity. The method is helpful in differentiating extra- from intra-articular causes of ankle impingement. Indirect MR-arthrography has little or no additional value in patients with ankle impingement syndrome.

  16. MR-imaging of anterior tibiotalar impingement syndrome: Agreement, sensitivity and specificity of MR-imaging and indirect MR-arthrography

    International Nuclear Information System (INIS)

    Haller, Joerg; Bernt, Reinhard; Seeger, Thomas; Weissenbaeck, Alexander; Tuechler, Heinrich; Resnick, Donald

    2006-01-01

    Objective: To clarify the role of MR-imaging in the diagnosis of anterior ankle impingement syndromes. Materials and methods: We prospectively examined 51 consecutive patients with chronic ankle pain by MR-imaging. Arthroscopy was performed in 29 patients who previously underwent non-enhanced MR-imaging; in 11 patients, indirect MR-arthrography additionally was performed. MR-examinations were correlated with clinical findings; MR and arthroscopy scores were statistically compared, agreement was measured. Results: Arthroscopy demonstrated granulation tissue in the lateral gutter (38%) and anterior recess (31%), lesions of the anterior tibiofibular (31%) and the anterior talofibular ligament (21%) as well as intraarticular bodies (10%). Stenosing tenosynovitis and a ganglionic cyst were revealed as extraarticular causes for chronic ankle pain by MR-examination (17%). Agreement of MR-imaging and arthroscopy was fair for the anterior talofibular ligament and the anterior joint cavity (kappa 0.40). Major discrepancy was found for non-enhanced MR scans (kappa 0.49) when compared with indirect MR-arthrography (kappa 0.03) in the anterior cavity. The sensitivity for lesions of the anterior talofibular and calcaneofibular ligament and the anterior cavity (0.91-0.87) detected by MR-imaging was superior in comparison to lesions of the anterior tibiofibular ligament and anteromedial cavity (0.50-0.24). Conclusion: MR-imaging provides additional information about the mechanics of chronic ankle impingement rather than an accurate diagnosis of this clinical entity. The method is helpful in differentiating extra- from intra-articular causes of ankle impingement. Indirect MR-arthrography has little or no additional value in patients with ankle impingement syndrome

  17. Magnetic resonance imaging

    International Nuclear Information System (INIS)

    Sigal, R.

    1988-01-01

    This book is an introduction to magnetic resonance imaging (MRI). The basic principles for the interpretation of MR images are developed. The book is divided into five chapters: introduction, tissue, parameters, acquisition parameters, contribution to diagnosis, and practical management of an MR examination. Eight exercises allow the reader to test the knowledge he has acquired. Signal localization and MR artefacts are reviewed in an appendix

  18. Electron Paramagnetic Resonance Imaging

    Indian Academy of Sciences (India)

    Twentieth century bore witness to remarkable scientists whohave advanced our understanding of the brain. Among them,EPR (Electron Paramagnetic Resonance) imaging is particularlyuseful in monitoring hypoxic zones in tumors which arehighly resistant to radiation and chemotherapeutic treatment.This first part of the ...

  19. Nuclear magnetic resonance imaging

    International Nuclear Information System (INIS)

    1983-06-01

    This report summarises the aspects of nuclear magnetic resonance imaging (NMRI) considered by the National Health Technology Advisory Panel and makes recommendations on its introduction in Australia with particular regard to the need for thorough evaluation of its cost effectiveness. Topics covered are: principles of the technique, equipment required, installation, costs, reliability, performance parameters, clinical indications, training and staff requirements, and safety considerations

  20. An overview of MR arthrography with emphasis on the current technique and applicational hints and tips

    International Nuclear Information System (INIS)

    Sahin, Guelden; Demirtas, Mehmet

    2006-01-01

    Magnetic resonance (MR) arthrography has been investigated in every major peripheral joint of the body, and has been proven to be effective in determining the integrity of intraarticular ligamentous and fibrocartilaginous structures and in the detection or assessment of osteochondral lesions and loose bodies in selected cases. Several methods could be used to create arthrogram effect during MR imaging, however, direct MR arthrography using diluted gadolinium as the contrast agent is the most commonly used technique and is the most reliable of all. MR arthrography is useful for demonstrating labrocapsular-ligamentous abnormalities and distinguishing partial thickness rotator cuff tears from focal full thickness tears in the shoulder, identifying or excluding recurrent tears following meniscal operations in the knee, demonstrating perforations of the triangular fibrocartilage complex (TFCC) and ligaments in the wrist, showing labral tears in the hip, diagnosing ligament tears in the ankle and identifying osteochondral lesions or loose bodies in any of the aforementioned joints. In this article, an overview of techniques of MR arthrography is provided with emphasis on direct MR arthrography using diluted gadolinium as the contrast agent. The current applications of the technique in major peripheral joints are reviewed, with emphasis given to the shoulder joint where the role of this technique has become well established

  1. An overview of MR arthrography with emphasis on the current technique and applicational hints and tips

    Energy Technology Data Exchange (ETDEWEB)

    Sahin, Guelden [Department of Radiology, Faculty of Medicine, Ankara University, Samanpazari, 06100 Ankara (Turkey)]. E-mail: gsahin@medicine.ankara.edu.tr; Demirtas, Mehmet [Department of Hand Surgery, Faculty of Medicine, Ankara University, Samanpazari, 06100 Ankara (Turkey)

    2006-06-15

    Magnetic resonance (MR) arthrography has been investigated in every major peripheral joint of the body, and has been proven to be effective in determining the integrity of intraarticular ligamentous and fibrocartilaginous structures and in the detection or assessment of osteochondral lesions and loose bodies in selected cases. Several methods could be used to create arthrogram effect during MR imaging, however, direct MR arthrography using diluted gadolinium as the contrast agent is the most commonly used technique and is the most reliable of all. MR arthrography is useful for demonstrating labrocapsular-ligamentous abnormalities and distinguishing partial thickness rotator cuff tears from focal full thickness tears in the shoulder, identifying or excluding recurrent tears following meniscal operations in the knee, demonstrating perforations of the triangular fibrocartilage complex (TFCC) and ligaments in the wrist, showing labral tears in the hip, diagnosing ligament tears in the ankle and identifying osteochondral lesions or loose bodies in any of the aforementioned joints. In this article, an overview of techniques of MR arthrography is provided with emphasis on direct MR arthrography using diluted gadolinium as the contrast agent. The current applications of the technique in major peripheral joints are reviewed, with emphasis given to the shoulder joint where the role of this technique has become well established.

  2. Cranial magnetic resonance imaging

    International Nuclear Information System (INIS)

    Elster, A.D.

    1988-01-01

    Cranial Magnetic Resonance Imaging is comprehensive, well structured, and well written. The material is current and well referenced. The illustrations are good and complement the text well. The overall quality of publication is above average. The greatest attribute of the book is its readability. The author demonstrates ample skill in making complex subjects, such as MR physics and imaging of cerebral hemorrhage, easy to understand. The book closes with a detailed atlas on the anatomic appearance of the brain on MR images in the axial, coronal, and sagittal planes

  3. Dental magnetic resonance imaging

    International Nuclear Information System (INIS)

    Hilgenfeld, Tim; Bendszus, Martin; Haehnel, Stefan

    2016-01-01

    Growing distribution and utilization of digital volume tomography (DVT) extend the spectrum of clinical dental imaging. Additional diagnostic value, however, comes along with an increasing amount of radiation. In contrast, magnetic resonance imaging is a radiation free imaging technique. Furthermore, it offers a high soft tissue contrast. Morphological and numerical dental anomalies, differentiation of periapical lesions and exclusion of complications of dental diseases are field of applications for dental MRI. In addition, detection of caries and periodontal lesions and injury of inferior alveolar nerve are promising application areas in the future.

  4. Magnetic Resonance Imaging (MRI) Safety

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) Safety What is MRI and how ... What is MRI and how does it work? Magnetic resonance imaging, or MRI, is a way of obtaining ...

  5. Magnetic Resonance Imaging of Stroke

    NARCIS (Netherlands)

    Bouts, Mark. J. R. J.; Wu, O.; Dijkhuizen, R. M.

    2017-01-01

    Magnetic resonance imaging (MRI) provides a powerful (neuro)imaging modality for the diagnosis and outcome prediction after (acute) stroke. Since MRI allows noninvasive, longitudinal, and three-dimensional assessment of vessel occlusion (with magnetic resonance angiography (MRA)), tissue injury

  6. A New Promising Technique of 3D Isovoxel Imaging Using 3T MRI in the Wrist: Comparison with 3T MR Arthrography

    International Nuclear Information System (INIS)

    Lee, Guen Young; Kim, Baek Hyun; Park, Jong Woong

    2011-01-01

    We wanted to evaluate the usefulness of 3D isovoxel MR imaging using 3T MRI in the wrist joint, as compared with 3T MR arthrography. A total of 33 patients underwent both MR arthrography and 3D isovoxel imaging of the wrist joints using 3T MR, including 11 patients with arthroscopic confirmation. 3D isovoxel MR imaging was performed using an intermediateweighted fast spin echo coronal scan with a 0.4-mm slice thickness and the axial images were reconstructed with a 1-mm slice thickness. One radiologist evaluated for the presence of scapholunate or lunotriquetral ligament tear and she determined the grade of the triangular fibrocartilage complex tear and chondromalacia with its location. We compared the two examinations using kappa values. The rates of detecting wrist injury were similar for both exams with substantial to almost perfect inter-examination agreement (kappa value = 0.864 for scapholunate ligament tear, 0.835 for lunotriquetral ligament tear, 0.799 for TFCC tear and 0.940 for chondromalacia). For the eleven cases that underwent arthroscopy, their results of 3D isovoxel MRI were also similar to that of MR arthrography. 3D isovoxel MR imaging is useful for the evaluation of the wrist joint

  7. A New Promising Technique of 3D Isovoxel Imaging Using 3T MRI in the Wrist: Comparison with 3T MR Arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Guen Young; Kim, Baek Hyun; Park, Jong Woong [Korea University Ansan Hospital, Korea University College of Medicine, Ansan (Korea, Republic of)

    2011-02-15

    We wanted to evaluate the usefulness of 3D isovoxel MR imaging using 3T MRI in the wrist joint, as compared with 3T MR arthrography. A total of 33 patients underwent both MR arthrography and 3D isovoxel imaging of the wrist joints using 3T MR, including 11 patients with arthroscopic confirmation. 3D isovoxel MR imaging was performed using an intermediateweighted fast spin echo coronal scan with a 0.4-mm slice thickness and the axial images were reconstructed with a 1-mm slice thickness. One radiologist evaluated for the presence of scapholunate or lunotriquetral ligament tear and she determined the grade of the triangular fibrocartilage complex tear and chondromalacia with its location. We compared the two examinations using kappa values. The rates of detecting wrist injury were similar for both exams with substantial to almost perfect inter-examination agreement (kappa value = 0.864 for scapholunate ligament tear, 0.835 for lunotriquetral ligament tear, 0.799 for TFCC tear and 0.940 for chondromalacia). For the eleven cases that underwent arthroscopy, their results of 3D isovoxel MRI were also similar to that of MR arthrography. 3D isovoxel MR imaging is useful for the evaluation of the wrist joint

  8. Children's (Pediatric) Magnetic Resonance Imaging

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging (MRI) ... limitations of Children’s (Pediatric) MRI? What is Children’s (Pediatric) MRI? Magnetic resonance imaging (MRI) is a noninvasive ...

  9. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging (MRI) ... limitations of Children’s (Pediatric) MRI? What is Children’s (Pediatric) MRI? Magnetic resonance imaging (MRI) is a noninvasive ...

  10. Magnetic Resonance Imaging (MRI) -- Head

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses a powerful ... the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that ...

  11. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging ( ... the limitations of Children’s (Pediatric) MRI? What is Children’s (Pediatric) MRI? Magnetic resonance imaging (MRI) is a ...

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses a powerful ... the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that ...

  13. Parallel magnetic resonance imaging

    International Nuclear Information System (INIS)

    Larkman, David J; Nunes, Rita G

    2007-01-01

    Parallel imaging has been the single biggest innovation in magnetic resonance imaging in the last decade. The use of multiple receiver coils to augment the time consuming Fourier encoding has reduced acquisition times significantly. This increase in speed comes at a time when other approaches to acquisition time reduction were reaching engineering and human limits. A brief summary of spatial encoding in MRI is followed by an introduction to the problem parallel imaging is designed to solve. There are a large number of parallel reconstruction algorithms; this article reviews a cross-section, SENSE, SMASH, g-SMASH and GRAPPA, selected to demonstrate the different approaches. Theoretical (the g-factor) and practical (coil design) limits to acquisition speed are reviewed. The practical implementation of parallel imaging is also discussed, in particular coil calibration. How to recognize potential failure modes and their associated artefacts are shown. Well-established applications including angiography, cardiac imaging and applications using echo planar imaging are reviewed and we discuss what makes a good application for parallel imaging. Finally, active research areas where parallel imaging is being used to improve data quality by repairing artefacted images are also reviewed. (invited topical review)

  14. Multidetector spiral CT arthrography of the shoulder

    Energy Technology Data Exchange (ETDEWEB)

    Lecouvet, Frederic E. [Departments of Radiology and Orthopaedic Surgery, Cliniques Universitaires Saint-Luc, Universite Catholique de Louvain, Hippocrate Avenue 10/2942, 1200 Brussels (Belgium)], E-mail: frederic.lecouvet@uclouvain.be; Simoni, Paolo; Koutaissoff, Sophie; Vande Berg, Bruno C.; Malghem, Jacques; Dubuc, Jean-Emile [Departments of Radiology and Orthopaedic Surgery, Cliniques Universitaires Saint-Luc, Universite Catholique de Louvain, Hippocrate Avenue 10/2942, 1200 Brussels (Belgium)

    2008-10-15

    Although MR imaging and MR arthrography are the first choice modalities for shoulder imaging, CT arthrography (CTA) may be used successfully to address many clinical questions. The advent of submillimeter multiple detector CT technology and subsequent excellent three-plane resolution has considerably increased the quality of CTA examinations and has propelled this technique to the forefront in a growing number of indications. The combined use of iodinated contrast material for fluoroscopic confirmation of the articular position of the needle before injection of gadolinium chelates for MR arthrography offers the unique opportunity to compare CTA and MRA findings in carefully selected cases. This paper illustrates capabilities and limits of CTA for the study of rotator cuff tears, shoulder instability, cartilage lesions, anatomical variants and abnormalities of the glenoid labrum, with correlations to MR arthrography and surgical findings.

  15. Multidetector spiral CT arthrography of the shoulder

    International Nuclear Information System (INIS)

    Lecouvet, Frederic E.; Simoni, Paolo; Koutaissoff, Sophie; Vande Berg, Bruno C.; Malghem, Jacques; Dubuc, Jean-Emile

    2008-01-01

    Although MR imaging and MR arthrography are the first choice modalities for shoulder imaging, CT arthrography (CTA) may be used successfully to address many clinical questions. The advent of submillimeter multiple detector CT technology and subsequent excellent three-plane resolution has considerably increased the quality of CTA examinations and has propelled this technique to the forefront in a growing number of indications. The combined use of iodinated contrast material for fluoroscopic confirmation of the articular position of the needle before injection of gadolinium chelates for MR arthrography offers the unique opportunity to compare CTA and MRA findings in carefully selected cases. This paper illustrates capabilities and limits of CTA for the study of rotator cuff tears, shoulder instability, cartilage lesions, anatomical variants and abnormalities of the glenoid labrum, with correlations to MR arthrography and surgical findings

  16. MR arthrography of the ankle joint

    International Nuclear Information System (INIS)

    Trattnig, S.; Rand, T.; Breitenseher, M.; Ba-Ssalamah, A.; Schick, S.; Imhof, H.

    1999-01-01

    Due to its superior soft tissue contrast conventional MRI is the imaging method of choice in the evaluation of ankle joint disorders. Conventional MR imaging can accurately demonstrate normal or acutely injured ligaments; however, in subacute and chronic injury joint fluid necessary for delineation of injured ligaments is absent and MR arthrography should be performed. MR arthrography uses the intraarticular injection of contrast material to distend the joint, yielding improved discrimination of intraarticular structures. This joint distension with MR arthrography is also helpful in the staging of osteochondritis dissecans, since in cases of unstable lesions tracking of contrast material into the interface can be more easily demonstrated. Finally, high contrast and joint distension by MR arthrography improves the detection of intraarticular loose bodies, which often require surgery. MR artrography, although invasive, may provide additional information in various ankle joint disorders. (orig.) [de

  17. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... As the hydrogen atoms return to their usual alignment, they emit different amounts of energy that vary ... story about radiology? Share your patient story here Images × Image Gallery Magnetic Resonance Imaging (MRI) procedure View ...

  18. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... it is useful to bring that to the attention of the scheduler before the exam and bring ... Image Gallery Magnetic Resonance Imaging (MRI) procedure View full size with caption Pediatric Content Some imaging tests ...

  19. MR arthrography including abduction and external rotation images in the assessment of atraumatic multidirectional instability of the shoulder

    Energy Technology Data Exchange (ETDEWEB)

    Schaeffeler, Christoph [Technische Universitaet Muenchen, Department of Radiology, Munich (Germany); Kantonsspital Graubuenden, Musculoskeletal Imaging, Chur (Switzerland); Waldt, Simone; Bauer, Jan S.; Rummeny, Ernst J.; Woertler, Klaus [Technische Universitaet Muenchen, Department of Radiology, Munich (Germany); Kirchhoff, Chlodwig [Technische Universitaet Muenchen, Department of Traumatology, Munich (Germany); Haller, Bernhard [Technische Universitaet Muenchen, Institute for Medical Statistics and Epidemiology, Munich (Germany); Schroeder, Michael [Center for Sports Orthopedics and Medicine, Orthosportiv, Munich (Germany); Imhoff, Andreas B. [Technische Universitaet Muenchen, Department of Orthopedic Sports Medicine, Munich (Germany)

    2014-06-15

    To evaluate diagnostic signs and measurements in the assessment of capsular redundancy in atraumatic multidirectional instability (MDI) of the shoulder on MR arthrography (MR-A) including abduction/external rotation (ABER) images. Twenty-one MR-A including ABER position of 20 patients with clinically diagnosed MDI and 17 patients without instability were assessed by three radiologists. On ABER images, presence of a layer of contrast between the humeral head (HH) and the anteroinferior glenohumeral ligament (AIGHL) (crescent sign) and a triangular-shaped space between the HH, AIGHL and glenoid (triangle sign) were evaluated; centring of the HH was measured. Anterosuperior herniation of the rotator interval (RI) capsule and glenoid version were determined on standard imaging planes. The crescent sign had a sensitivity of 57 %/62 %/48 % (observers 1/2/3) and specificity of 100 %/100 %/94 % in the diagnosis of MDI. The triangle sign had a sensitivity of 48 %/57 %/48 % and specificity of 94 %/94 %/100 %. The combination of both signs had a sensitivity of 86 %/90 %/81 % and specificity of 94 %/94 %/94 %. A positive triangle sign was significantly associated with decentring of the HH. Measurements of RI herniation, RI width and glenoid were not significantly different between both groups. Combined assessment of redundancy signs on ABER position MR-A allows for accurate differentiation between patients with atraumatic MDI and patients with clinically stable shoulders; measurements on standard imaging planes appear inappropriate. (orig.)

  20. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... for Brain Tumors Radiation Therapy for Head and Neck Cancer Others : American Stroke Association National Stroke Association ... MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain Tumor Treatment Magnetic Resonance Imaging ( ...

  1. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging (MRI) uses ... identify and accurately characterize diseases than other imaging methods. This detail makes MRI an invaluable tool in ...

  2. Magnetic resonance imaging. 1

    International Nuclear Information System (INIS)

    Wall, E.E. van der; Roos, A.A. de; Doornbos, J.; Dijkman, P.R.M. van; Matheijssen, N.A.A.; Laarse, A. van der; Krauss, X.H.; Blokland, J.A.k.; Manger Cats, V.; Voorthuisen, A.E. van; Bruschke, A.V.G.

    1991-01-01

    The cardiovascular applications of MRI in coronary artery disease have considerably increased in recent years. Although many applications overlap those of other more cost-effective techniques, such as echocardiography, radionuclide angiography, and CT, MRI offers unique features not shared by the conventional techniques. Technical advantages are the excellent spatial resolution, the characterization of myocardial tissue, and the potential for three-dimensional imaging. This allows the accurate assessment of left ventricular mass and volume, the differentiation of infarcted tissue from normal myocardial tissue, and the determination of systolic wall thickening and regional wall motion abnormalities. Also inducible myocardial ischemia using pharmacological stress (dipyramidole or dobutamine) may be assessed by magnetic resonance imaging. Future technical developments include real-time imaging and noninvasive visualization of the coronary arteries. These advantages will have a major impact on the application of MRI in coronary artery disease, potentially unsurpassed by other techniques and certainly justifying the expenses. Consequently, the clinical use of MRI for the detection of coronary artery disease largely depends on the progress of technical developments. (author). 134 refs.; 10 figs.; 2 tabs

  3. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... As the hydrogen atoms return to their usual alignment, they emit different amounts of energy that vary ... story about radiology? Share your patient story here Images × Image Gallery Radiologist prepping patient for magnetic resonance ...

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... by the interpreting radiologist. Frequently, the differentiation of abnormal (diseased) tissue from normal tissues is better with ... Tumor Treatment Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain Tumors Images related to Magnetic ...

  5. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... it is useful to bring that to the attention of the technologist or scheduler before the exam. ... patient for magnetic resonance imaging (MRI) exam. View full size with caption Pediatric Content Some imaging tests ...

  6. Magnetic Resonance Imaging. Chapter 15

    Energy Technology Data Exchange (ETDEWEB)

    Leach, M. O. [The Institute of Cancer Research and The Royal Marsden Hospital, London (United Kingdom)

    2014-09-15

    In Chapter 14, the principles of nuclear magnetic resonance were presented, along with an introduction to image forming processes. In this chapter, magnetic resonance imaging (MRI) will be reviewed, beginning with the hardware needed and its impact on image quality. The acquisition processes and image reconstruction will be discussed, as well as the artefacts that are possible, with discussion of the important area of safety and bioeffects completing the chapter.

  7. Magnetic resonance imaging methodology

    International Nuclear Information System (INIS)

    Moser, Ewald; Stadlbauer, Andreas; Windischberger, Christian; Quick, Harald H.; Ladd, Mark E.

    2009-01-01

    Magnetic resonance (MR) methods are non-invasive techniques to provide detailed, multi-parametric information on human anatomy, function and metabolism. Sensitivity, specificity, spatial and temporal resolution may, however, vary depending on hardware (e.g., field strength, gradient strength and speed) and software (optimised measurement protocols and parameters for the various techniques). Furthermore, multi-modality imaging may enhance specificity to better characterise complex disease patterns. Positron emission tomography (PET) is an interesting, largely complementary modality, which might be combined with MR. Despite obvious advantages, combining these rather different physical methods may also pose challenging problems. At this early stage, it seems that PET quality may be preserved in the magnetic field and, if an adequate detector material is used for the PET, MR sensitivity should not be significantly degraded. Again, this may vary for the different MR techniques, whereby functional and metabolic MR is more susceptible than standard anatomical imaging. Here we provide a short introduction to MR basics and MR techniques, also discussing advantages, artefacts and problems when MR hardware and PET detectors are combined. In addition to references for more detailed descriptions of MR fundamentals and applications, we provide an early outlook on this novel and exciting multi-modality approach to PET/MR. (orig.)

  8. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging (MRI) uses a powerful ... for an MRI exam contains a metal called gadolinium . Gadolinium can be used in patients with iodine ...

  9. Ultra-high resolution C-Arm CT arthrography of the wrist: Radiation dose and image quality compared to conventional multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Werncke, Thomas, E-mail: Werncke.Thomas@mh-hannover.de [Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover (Germany); Sonnow, Lena; Meyer, Bernhard C. [Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover (Germany); Lüpke, Matthias [University of Veterinary Medicine Hannover, Institute for General Radiology and Medical Physics, Bischofsholer Damm 15, 30173 Hannover (Germany); Hinrichs, Jan; Wacker, Frank K.; Falck, Christian von [Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover (Germany)

    2017-04-15

    Objective: Objective of this phantom and cadaveric study was to compare the effective radiation dose (ED) and image quality (IQ) between C-arm computed tomography (CACT) using an ultra-high resolution 1 × 1 binning with a standard 16-slice CT (MDCT) arthrography of the wrist. Methods: ED was determined with thermoluminescence dosimetry using an anthropomorphic phantom and different patient positions. Imaging was conducted in 10 human cadaveric wrists after tri-compartmental injection of diluted iodinated contrast material and a wire phantom. IQ of MDCT was compared with CACT reconstructed with a soft (CACT1) and sharp (CACT2) kernel. High and low contrast resolution was determined. Three radiologists assessed IQ of wrist structures and occurrence of image artifacts using a 5-point Likert scale. Results: ED of MDCT was comparable to standard CACT (4.3 μSv/3.7 μSv). High contrast resolution was best for CACT2, decreased to CACT1 and MDCT. Low contrast resolution increased between CACT2 and MDCT (P < 0.001). IQ was best for CACT2 (1.3 ± 0.5), decreased to CACT1 (1.9 ± 0.6) and MDCT (3.5 ± 0.6). Non-compromising artifacts were only reported for CACT. Conclusions: The results of this phantom and cadaveric study indicate that ultra-high resolution C-Arm CT arthrography of the wrist bears the potential to outperform MDCT arthrography in terms of image quality and workflow at the cost of mildly increasing image artifacts while radiation dose to the patient is comparably low for both, MDCT and C-Arm CT.

  10. Ulnar-sided wrist pain. II. Clinical imaging and treatment

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Atsuya; Souza, Felipe [Brigham and Women' s Hospital, Department of Radiology, Boston, MA (United States); Vezeridis, Peter S.; Blazar, Philip [Brigham and Women' s Hospital, Department of Orthopaedic Surgery, Boston, MA (United States); Yoshioka, Hiroshi [Brigham and Women' s Hospital, Department of Radiology, Boston, MA (United States); University of California-Irvine, Department of Radiological Sciences, Irvine, CA (United States); UC Irvine Medical Center, Department of Radiological Sciences, Orange, CA (United States)

    2010-09-15

    Pain at the ulnar aspect of the wrist is a diagnostic challenge for hand surgeons and radiologists due to the small and complex anatomical structures involved. In this article, imaging modalities including radiography, arthrography, ultrasound (US), computed tomography (CT), CT arthrography, magnetic resonance (MR) imaging, and MR arthrography are compared with regard to differential diagnosis. Clinical imaging findings are reviewed for a more comprehensive understanding of this disorder. Treatments for the common diseases that cause the ulnar-sided wrist pain including extensor carpi ulnaris (ECU) tendonitis, flexor carpi ulnaris (FCU) tendonitis, pisotriquetral arthritis, triangular fibrocartilage complex (TFCC) lesions, ulnar impaction, lunotriquetral (LT) instability, and distal radioulnar joint (DRUJ) instability are reviewed. (orig.)

  11. Imaging of the knee joint with emphasis on magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Reiser, M.F. [Radiologische Universitaetsklinik, Rheinische Friedrich-Wilhelms-Univ., Bonn (Germany); Vahlensieck, M. [Radiologische Universitaetsklinik, Rheinische Friedrich-Wilhelms-Univ., Bonn (Germany); Schueller, H. [Radiologische Universitaetsklinik, Rheinische Friedrich-Wilhelms-Univ., Bonn (Germany)

    1992-04-01

    The knee joint is frequently affected by trauma as well as degenerative and inflammatory disorders, involving the internal structures (i.e. ligaments, menisci, cartilage, synovial membrane) and the adjacent bones. Plain radiographs represent an indispensable basis for diagnosis. For further analysis magnetic resonance imaging (MRI) has become the method of choice, and has widely replaced computed tomography, arthrography and stress examinations. Extensive experience has been accumulated in MRI of the knee joint in recent years. In addition, advances in MRI technology have had a major impact on diagnostic accuracy. In this paper, diagnosis of various lesions of the knee joint, such as meniscal and ligamental injuries, aseptic necrosis, lesions of the hyaline cartilage, occult fractures and inflammatory lesions will be discussed. (orig.)

  12. MR arthrography of the shoulder: possible indications for clinical use

    International Nuclear Information System (INIS)

    Kreitner, K.F.; Grebe, P.; Kersjes, W.; Runkel, M.; Kirschner, P.; Schild, H.H.

    1994-01-01

    In a prospective study possible indications for MR arthrography of the shoulder were evaluated. 37 patients were examined before and after intraarticular administration of a 2-mmolar solution of Gd-DTPA. MR arthrography was performed if there was no joint effusion and/or an uncertain finding concerning the rotator cuff or the capsulolabral complex on plain MR images. MR arthrography leads to a better demonstration of labrum pathology in 11/22 patients and to a superior delineation of the capsuloligamentous apparatus in 20/22 cases. In 9/15 patients with impingement lesions MR arthrography allowed a differentiation of severe tendinitis from partial and small full-thickness tears of the rotator cuff. MR arthrography of the shoulder joint enhances the accuracy of MR in case of an uncertain finding on plain MR images. (orig.) [de

  13. Is a single direct MR arthrography series in ABER position as accurate in detecting anteroinferior labroligamentous lesions as conventional MR arthography?

    Energy Technology Data Exchange (ETDEWEB)

    Schreinemachers, Saskia A.; Hulst, Victor P.M. van der; Woude, Henk-Jan van der [Onze Lieve Vrouwe Gasthuis, Department of Radiology, Amsterdam (Netherlands); Jaap Willems, W. [Onze Lieve Vrouwe Gasthuis, Orthopaedic Surgery, Amsterdam (Netherlands); Bipat, Shandra [University of Amsterdam, Department of Radiology, Academic Medical Centre, Amsterdam (Netherlands)

    2009-07-15

    The purpose of this study is to retrospectively compare accuracy of single magnetic resonance (MR) arthrography series in Abduction External Rotation (ABER) with conventional MR arthrography for detection and characterisation of anteroinferior labroligamentous lesions, with arthroscopy as reference standard. Inter-observer variability of both protocols was determined. Institutional review board approval was obtained; informed consent was waived. MR arthrograms, including oblique axial fat suppressed T1-weighted images in ABER position and conventional imaging directions of 250 patients (170 men, 80 women; mean age, 36 years), were retrospectively and independently evaluated by three reviewers. Reviewers were blinded to clinical information and arthroscopic results. Labroligamentous lesions were registered in both ABER and MRa. The lesions were sub-classified (Bankart, Perthes, anterior labrum periosteal sleeve avulsion (ALPSA) or lesions not otherwise specified). Inter-observer agreement was assessed by Kappa statistics for all 250 patients. Ninety-two of 250 patients underwent arthroscopy. Sensitivity, specificity and accuracy of ABER versus conventional MR arthrography were calculated and compared using paired McNemar test. Kappa values of the ABER and conventional MR arthrography ranged from 0.44 to 0.56 and 0.44 to 0.62, respectively. According to arthroscopy, 45 of 92 patients had an intact anteroinferior labrum, and in 44 patients, a labroligamentous lesion (eight Bankart, seven Perthes, 29 ALPSA and three lesions not otherwise specified) was diagnosed. There were no statistically significant differences between ABER and conventional MR arthrography regarding sensitivity (85-89%, 89-96%), specificity (82-91%, 84-89%) and overall accuracy (50-62%, 53-63%). The results of a single MR arthrography series in ABER position are comparable with those of conventional MR arthrography for detecting anteroinferior labroligamentous lesions. (orig.)

  14. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... work? Unlike conventional x-ray examinations and computed tomography (CT) scans, MRI does not utilize ionizing radiation. Instead, ... Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's (Pediatric) CT (Computed Tomography) Magnetic Resonance Imaging (MRI) Safety Contrast Materials Children ...

  15. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... is not harmful, but it may cause some medical devices to malfunction. Most orthopedic implants pose no ... Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. ...

  16. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... are the limitations of MRI of the Head? What is MRI of the Head? Magnetic resonance imaging ( ... brain) in routine clinical practice. top of page What are some common uses of the procedure? MR ...

  17. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... magnetic resonance imaging (MRI) uses a powerful magnetic field, radio waves and a computer to produce detailed ... problems, medications, recent surgeries and allergies. The magnetic field is not harmful, but it may cause some ...

  18. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... MRI) exam. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Catheter Angiography Magnetic Resonance, ...

  19. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... be necessary. Your doctor will explain the exact reason why another exam is requested. Sometimes a follow- ... necessary in trauma situations. Although there is no reason to believe that magnetic resonance imaging harms the ...

  20. Magnetic resonance imaging the basics

    CERN Document Server

    Constantinides, Christakis

    2014-01-01

    Magnetic resonance imaging (MRI) is a rapidly developing field in basic applied science and clinical practice. Research efforts in this area have already been recognized with five Nobel prizes awarded to seven Nobel laureates in the past 70 years. Based on courses taught at The Johns Hopkins University, Magnetic Resonance Imaging: The Basics provides a solid introduction to this powerful technology. The book begins with a general description of the phenomenon of magnetic resonance and a brief summary of Fourier transformations in two dimensions. It examines the fundamental principles of physics for nuclear magnetic resonance (NMR) signal formation and image construction and provides a detailed explanation of the mathematical formulation of MRI. Numerous image quantitative indices are discussed, including (among others) signal, noise, signal-to-noise, contrast, and resolution. The second part of the book examines the hardware and electronics of an MRI scanner and the typical measurements and simulations of m...

  1. MR arthrography of the knee

    International Nuclear Information System (INIS)

    Kramer, J. Jr.; Engel, A. Jr.; Stiglbauer, R.; Prayer, L. Jr.; Hajek, P. Jr.; Imhof, H.

    1991-01-01

    This paper reports on MR imaging which has gained increasing importance as a diagnostic instrument in orthopedics. The key to joint diagnostics - the evaluation of hyaline articular cartilage - however, has not been touched sufficiently by this development. Fundamental studies were done and 140 patients were examined with MR imaging after intraarticular administration of contrast agent. Hyaline cartilage, cruciate ligaments, and menisci were assessed before and after injection of a 2-mmol/L Gd-DTPA solution, and the results were compared with those of arthroscopy/arthrotomy. MR arthrography provided superior image quality compared with plain MR imaging. This resulted in an improved delineation of intraarticular structures, especially of cartilage defects

  2. Superresolution Imaging Using Resonant Multiples

    KAUST Repository

    Guo, Bowen

    2017-12-22

    A resonant multiple is defined as a multiple reflection that revisits the same subsurface location along coincident reflection raypaths. We show that resonant first-order multiples can be migrated with either Kirchhoff or wave-equation migration methods to give images with approximately twice the spatial resolution compared to post-stack primary-reflection images. A moveout-correction stacking method is proposed to enhance the signal-to-noise ratios (SNRs) of the resonant multiples before superresolution migration. The effectiveness of this procedure is validated by synthetic and field data tests.

  3. Superresolution Imaging Using Resonant Multiples

    KAUST Repository

    Guo, Bowen; Schuster, Gerard T.

    2017-01-01

    A resonant multiple is defined as a multiple reflection that revisits the same subsurface location along coincident reflection raypaths. We show that resonant first-order multiples can be migrated with either Kirchhoff or wave-equation migration methods to give images with approximately twice the spatial resolution compared to post-stack primary-reflection images. A moveout-correction stacking method is proposed to enhance the signal-to-noise ratios (SNRs) of the resonant multiples before superresolution migration. The effectiveness of this procedure is validated by synthetic and field data tests.

  4. Magnetic resonance imaging

    International Nuclear Information System (INIS)

    Murphy, W.A.

    1988-01-01

    After only a few years, MR imaging has proved to be an important method for imaging disorders of the musculoskeletal tissues. The images are characterized by great inherent contrast, excellent spatial resolution, and exquisite anatomic display - major reasons why MR imaging compares favorably with other imaging methods, such as radionuclide bone scanning and CT. MR imaging is particularly sensitive to bone marrow alterations and is very effective for detection and characterization of a wide variety of soft tissue conditions. Advances in surface coil technology will increase the usefulness of MR imaging in the evaluation of articular disease. In addition, chemical shift imaging and spectroscopy will add physiologic information to the anatomic features demonstrated by proton imaging

  5. Instability of the long head of the biceps tendon in patients with rotator cuff tear: evaluation on magnetic resonance arthrography of the shoulder with arthroscopic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Yusuhn; Lee, Joon Woo; Ahn, Joong Mo; Lee, Eugene; Kang, Heung Sik [Seoul National University Bundang Hospital, Department of Radiology, Seongnam-si, Gyeonggi-do (Korea, Republic of)

    2017-10-15

    To evaluate the diagnostic value of MR arthrography (MRA) in diagnosing instability of the LHBT in patients with rotator cuff tendon tear. The MR arthrograms of 101 patients were retrospectively reviewed and correlated with arthroscopic findings as the standard reference. Images were evaluated for (1) the integrity of the LHBT, (2) the position of the LHBT (subluxation/dislocation on axial images, inferior displacement on oblique sagittal image) and (3) the integrity of the biceps pulley (SGHL, supraspinatus and subscapularis tendon adjacent to the rotator interval). The integrity of the LHBT was correctly classified in 74.3% (75/101) and 66.3% (67/101) by readers 1 and 2, respectively. The diagnosis of LHBT instability could be made on axial images with a sensitivity of 82.6% and 73.9% and specificity of 69.9% and 87.7%, whereas the displacement sign on sagittal images had a sensitivity of 73.9% and 78.3% and a specificity of 64.4% and 61.6%, respectively. Assessing the integrity of the SGHL had a sensitivity of 60.9 and 93.3% and a specificity of 70.4 and 75.0%, respectively. By combining the different image findings, the accuracy in assessing LHBT instability was 80.9 and 90.5% with a sensitivity of 60.9 and 86.7% and specificity of 83.1 and 91.8%, respectively. Individual image findings may have a limited role in diagnosing LHBT instability in patients with rotator cuff tendon tear. The accuracy of MRA may be improved by assessing the integrity of the biceps pulley structures along with the position of the LHBT on both axial and sagittal images. (orig.)

  6. Magnetic resonance vascular imaging

    International Nuclear Information System (INIS)

    Axel, L

    1989-01-01

    The basis principles of MRI are reviewed in order to understand how blood flow effects arise in conventional imaging. Then some of the ways these effects have ben used in MRI techniques specifically designed for vascular imaging, are considered. (author)

  7. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - ...

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. MRI ...

  9. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. MRI ...

  10. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... of which shows a thin slice of the body. The images can then be studied from different angles by ... about radiology? Share your patient story here Images ... Articles and Media Catheter Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's ( ...

  11. Knee arthrography today

    International Nuclear Information System (INIS)

    Otto, H.; Kallenberger, R.

    1987-01-01

    The role of knee arthrography today is demonstrated and technical problems are discussed. Among a lot of variants the position of the patient and the choice of contrast media play a great part concerning the result of the examination. Mild complications occur in 0.25% of the examinations, severe and live threatening complications are extremely rare. Diagnosis of meniscal lesions is most important for knee arthrography; arthroscopy and arthrography are complementary examinations and not mutually exclusive, they achieve combined an accuracy of 97-98%. In the same way arthrography is able to evaluate the condropathy of the femoro-tibial joint, whereas accuracy of arthroscopy in the diagnosis of patellar chondropathy is much higher. There is a great reliability of arthrography regarding the evaluation of lesions of the capsule, but accuracy in lesions of the cruciate ligaments is low. Arthrography is very suitable for evaluation of Baker-cysts, since indications for almost occuring internal derangement of the knee are even available. Knee arthrography is a complex and safe procedure with very less discomfort for the patient; it has a central position in the evaluation of lesions of the knee. (orig.) [de

  12. Magnetic resonance imaging

    International Nuclear Information System (INIS)

    Beer, A.; Bielke, G.; Bockenheimer, S.; Brenner, G.; Dieringer, H.; Esswein, H.; Hopf, H.; Koch, H.; Meves, M.; Nagel, F.; Oberstein, A.; Ostheimer, E.; Pfaff, M.; Schlaps, D.; Schopka, H.J.; Seiderer, M.

    1990-01-01

    The study investigates three points of main interest: (1) The clinical efficacy of MR imaging as a routine method, if possible to be assessed in comparison to comparable imaging methods, and referring to a broad spectrum of available types of equipment and modes of operation, to be expressed in terms of diagnostic value and indication of therapy. (2) Specific economic aspects, considering different sites of operation and application conditions. (3) Results of clinical application with regard to individual cases (patient careers), in order to establish a nationwide basis for economic cost-benefit assessment of this diagnostic tool. Another aspect taken into account whenever available data allow so, is substitutional or additional application of MR imaging. The survey is performed on the basis of data accumulated by more than 21.000 MR examinations, and of data describing the application environment, furnished by 25 users from university hospitals, general hospitals, or private practice. (orig./HP) [de

  13. Interventional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Debatin, J.F.; Adam, G.

    1998-01-01

    With the advent of open configuration MR imaging systems, the vision of MRI-based guidance, control, and monitoring of minimally invasive interventions has evolved from a hypothetical concept to a practical possibility. This book provides a comprehensive overview of the very exciting emerging field of interventional MRI. The international authorship provides firsthand experience of all relevant topics. This book will familiarize the reader with the basic principles underlying currently available hardware and software configurations. In addition, technical aspects of thermosensitive imaging, techniques for instrument visualization, and safety aspects are covered. Finally, the book emphasizes both existing and future clinical applications. (orig.)

  14. Diagnostic performance of indirect MR arthrography for the diagnosis of rotator cuff tears at 3.0 T.

    Science.gov (United States)

    Lee, Ji Hyun; Yoon, Young Cheol; Jee, Sukkyung

    2015-06-01

    Indirect magnetic resonance (MR) arthrography is a non-invasive method for shoulder imaging. However, there are no studies that have examined the diagnostic performance of indirect MR arthrography for the diagnosis of rotator cuff tears in a large patient population. To assess the diagnostic performance of indirect fast spin-echo (FSE) MR arthrography for the diagnosis of rotator cuff tears at 3.0 T. A total of 149 patients who had undergone indirect shoulder MR arthrography followed by arthroscopic surgery were enrolled in this retrospective study. Two musculoskeletal radiologists evaluated images from each patient for the presence of supraspinatus-infraspinatus (SSP-ISP) or subscapularis (SSC) tendon tears. Using the arthroscopic findings as the reference standard, the overall diagnostic performance and detection rates for SSP-ISP and SSC tendon tears were calculated. The sensitivity, specificity, and accuracy of readers I and II for the diagnosis of SSP-ISP tendon tears were 94% and 95%, 89% and 85%, and 93% and 93%, respectively. The sensitivity of imaging for detection of SSP-ISP tendon tears by readers I and II were 100% and 100% for full-thickness tears and 84% and 86% for partial-thickness tears, respectively. The sensitivity, specificity, and accuracy of readers I and II for the diagnosis of SSC tendon tears were 80% and 76%, 89% and 93%, and 85% and 85%, respectively. Indirect MR arthrography is useful for the detection of SSP-ISP and SSC tendon tears. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  15. Electron Paramagnetic Resonance Imaging

    Indian Academy of Sciences (India)

    IAS Admin

    is Professor of Chemistry at. IIT Madras. ... speeding up the CW imaging by special novel methods. How- ever, the ... presence of gradients which are applied in two or three dimen- sions and ... optics and mechanical engineer- ing stands for ...

  16. Evaluation of the Subscapularis Tendon Tears on 3T Magnetic Resonance Arthrography: Comparison of Diagnostic Performance of T1-Weighted Spectral Presaturation with Inversion-Recovery and T2-Weighted Turbo Spin-Echo Sequences.

    Science.gov (United States)

    Lee, Hoseok; Ahn, Joong Mo; Kang, Yusuhn; Oh, Joo Han; Lee, Eugene; Lee, Joon Woo; Kang, Heung Sik

    2018-01-01

    To compare the T1-weighted spectral presaturation with inversion-recovery sequences (T1 SPIR) with T2-weighted turbo spin-echo sequences (T2 TSE) on 3T magnetic resonance arthrography (MRA) in the evaluation of the subscapularis (SSC) tendon tear with arthroscopic findings as the reference standard. This retrospective study included 120 consecutive patients who had undergone MRA within 3 months between April and December 2015. Two musculoskeletal radiologists blinded to the arthroscopic results evaluated T1 SPIR and T2 TSE images in separate sessions for the integrity of the SSC tendon, examining normal/articular-surface partial-thickness tear (PTTa)/full-thickness tear (FTT). Diagnostic performance of T1 SPIR and T2 TSE was calculated with arthroscopic results as the reference standard, and sensitivity, specificity, and accuracy were compared using the McNemar test. Interobserver agreement was measured with kappa (κ) statistics. There were 74 SSC tendon tears (36 PTTa and 38 FTT) confirmed by arthroscopy. Significant differences were found in the sensitivity and accuracy between T1 SPIR and T2 TSE using the McNemar test, with respective rates of 95.9-94.6% vs. 71.6-75.7% and 90.8-91.7% vs. 79.2-83.3% for detecting tear; 55.3% vs. 31.6-34.2% and 85.8% vs. 78.3-79.2%, respectively, for FTT; and 91.7-97.2% vs. 58.3-61.1% and 89% vs. 78-79.3%, respectively, for PTTa. Interobserver agreement for T1 SPIR was almost perfect for T1 SPIR (κ = 0.839) and substantial for T2 TSE (κ = 0.769). T1-weighted spectral presaturation with inversion-recovery sequences is more sensitive and accurate compared to T2 TSE in detecting SSC tendon tear on 3T MRA.

  17. CT-guided puncture for direct MR-arthrography of the shoulder: Description of possible techniques

    Directory of Open Access Journals (Sweden)

    Hauth E

    2016-07-01

    Full Text Available The following report describes the possible techniques of CT-guided puncture for direct magnetic resonance (MR arthrography of the shoulder. CT-guided puncture can be regarded as an alternative technique to fluoroscopic- or ultrasound-guided puncture for MR-arthrography of the shoulder with high efficiency, low dose and extremely low complication rate.

  18. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance ...

  19. Low field magnetic resonance imaging

    Science.gov (United States)

    Pines, Alexander; Sakellariou, Dimitrios; Meriles, Carlos A.; Trabesinger, Andreas H.

    2010-07-13

    A method and system of magnetic resonance imaging does not need a large homogenous field to truncate a gradient field. Spatial information is encoded into the spin magnetization by allowing the magnetization to evolve in a non-truncated gradient field and inducing a set of 180 degree rotations prior to signal acquisition.

  20. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Magnetic Resonance Imaging Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ... links: For the convenience of our users, RadiologyInfo .org provides links to relevant websites. RadiologyInfo.org , ACR ...

  1. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... structures of the brain and can also provide functional information (fMRI) in selected cases. MR images of ... Articles and Media MR Angiography (MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain ...

  2. Arthrography of the ankle

    International Nuclear Information System (INIS)

    Lindholmer, E.; Foged, N.; Jensen, J. Th.

    1978-01-01

    Arthrography was performed in 105 cases with freshly sprained ankles and signs of rupture of the anterior talofibular ligament. They were subsequently operated upon. The arthrographic films were examined retrospectively to assess the value of different criteria for the differential diagnosis between rupture of the anterior talofibular ligament and combined rupture of this and the calcaneofibular ligament. The diagnostic value of arthrography was found to be high in isolated rupture of the anterior talofibular ligament, and is acceptable in the combined ruptures. (Auth.)

  3. MR arthrography gadolinium versus standard MR imaging in rotator cuff pathology

    International Nuclear Information System (INIS)

    Hodler, J.; Brahme, S.K.; Karzel, R.; Cervilla, V.; Snyder, S.; Schweitzer, M.; Flannigan, B.; Resnick, D.

    1990-01-01

    This paper compares the accuracy of MR imaging with and without intraarticular gadolinium in the diagnosis of rotator cuff pathology, using arthroscopy as the gold standard. The authors examined 36 patients, first with T2-weighted sequences and then with T1-weighted sequences after the injection of 15-20 mL of diluted gadolinium. The images were read blindly by three radiologists experienced in musculoskeletal MR imaging. The results were compared with those of arthroscopy. In 16 of 19 arthroscopically intact rotator cuffs, both sequences demonstrated no evidence of rotator cuff tear. The remaining three cases were interpreted as partial or full-thickness tears. Of 12 partial tears, T1-weighted images with intraarticular gadolinium demonstrated a partial tear in five, degeneration in four, a full thickness tear in two, and a normal rotator cuff in one

  4. Adhesive capsulitis of the shoulder: evaluation with MR arthrography

    International Nuclear Information System (INIS)

    Jung, Joon-Yong; Jee, Won-Hee; Chun, Ho Jong; Kim, Yang-Soo; Chung, Yang Guk; Kim, Jung-Man

    2006-01-01

    The purpose of this study was to determine the usefulness of magnetic resonance (MR) arthrography for diagnosing adhesive capsulitis. Shoulder MR images of 28 patients with (n=14) and without (n=14) adhesive capsulitis were retrospectively analyzed. MR images were assessed for capsule and synovium thickness as well as the width of the axillary recess on oblique coronal fat-suppressed T1-weighted images and T2-weighted images, respectively. On oblique sagittal fat-suppressed T1-weighted images, the width of the rotator interval and the presence of abnormal tissue in the interval were evaluated. Significant differences were found between the two groups in capsule and synovium thickness on both sides of the recess on oblique coronal T2-weighted images (P=0.000), whereas thickness on the humeral aspect showed no significant difference on oblique coronal fat-suppressed T1-weighted images (P=0.109). On oblique coronal T2-weighted images, a cut-off value of 3-mm thickness gave the highest diagnostic accuracy for adhesive capsulitis with sensitivity, specificity, and accuracy of 79% (11/14), 100% (14/14), and 89% (25/28) at the humeral side and 93% (13/14), 86% (12/14), and 89% (25/28) at the glenoid side, respectively. There were significant differences in rotator interval width, presence of abnormal tissue in the rotator interval, and axillary recess width between the two groups (P<0.05). Thickness of capsule and synovium of the axillary recess greater than 3 mm is a practical MR criterion for diagnosing adhesive capsulitis when measured on oblique coronal T2-weighted MR arthrography images without fat suppression. The presence of abnormal tissue in the rotator interval showed high sensitivity but rather low specificity. (orig.)

  5. Principles of magnetic resonance imaging

    International Nuclear Information System (INIS)

    Mlynarik, V.; Tkac, I.; Srbecky, M.

    1995-01-01

    The aim of this review is to describe and explain the basic principles of magnetic resonance imaging. The first part of the text is devoted to the phenomenon of magnetic resonance (the interaction of RF magnetic field with the set of magnetic moments in the homogeneous magnetic field) and to relaxation processes. Then, the creation of MR image is described (slice selection, phase and frequency encoding of spatial information). The basic and the most frequently used techniques are explained (spin echo, gradient echo). The way the repetition and echo times influence the image quality and contrast (T1 or T2 weighing) is described. The part with the technical description of the MR equipment is included in the review. The MR imagination examination are compared with X-ray computer tomography technique

  6. Magnetic resonance imaging of the triangular fibrocartilage complex. Usefulness of the fat suppression MRI

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Toshiyasu [Fujita Health Univ., Nagoya (Japan). Second Hospital; Yabe, Yutaka; Horiuchi, Yukio; Kikuchi, Yoshito; Makita, Satoo

    1996-08-01

    Advances in magnetic resonance imaging (MRI) now allow for the visualization of small structures, such as the triangular fibrocartilage complex (TFCC) of the wrist. Recent investigators suggested that MRI is useful in delineation of the TFCC itself and its abnormality, and supported that diagnostic value of MRI for the TFCC tears is almost equal to those of arthrography and arthroscopy. In contrast, there were several reports that representation of the TFCC in MRI was less worth than in arthrography. Further, it was reported that MRI was not useful because abnormal findings existed at normal volunteers` wrists. Recent development of the pulse sequence is remarkable, such as gradient echo, fast spin echo and fat suppression method. However, as the previous MR studies of the TFCC mainly using conventional spin echo pulse sequence, there were a few comparison of each pulse sequence and we do not know how each pulse sequence delineates the TFCC. Therefore, we studied MRI of the TFCC using several pulse sequence in normal volunteers, and compared MR slices of the TFCC with corresponding histological sections to evaluate shape detectability of MRI. (J.P.N.)

  7. Technical errors in MR arthrography

    International Nuclear Information System (INIS)

    Hodler, Juerg

    2008-01-01

    This article discusses potential technical problems of MR arthrography. It starts with contraindications, followed by problems relating to injection technique, contrast material and MR imaging technique. For some of the aspects discussed, there is only little published evidence. Therefore, the article is based on the personal experience of the author and on local standards of procedures. Such standards, as well as medico-legal considerations, may vary from country to country. Contraindications for MR arthrography include pre-existing infection, reflex sympathetic dystrophy and possibly bleeding disorders, avascular necrosis and known allergy to contrast media. Errors in injection technique may lead to extra-articular collection of contrast agent or to contrast agent leaking from the joint space, which may cause diagnostic difficulties. Incorrect concentrations of contrast material influence image quality and may also lead to non-diagnostic examinations. Errors relating to MR imaging include delays between injection and imaging and inadequate choice of sequences. Potential solutions to the various possible errors are presented. (orig.)

  8. Technical errors in MR arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Hodler, Juerg [Orthopaedic University Hospital of Balgrist, Radiology, Zurich (Switzerland)

    2008-01-15

    This article discusses potential technical problems of MR arthrography. It starts with contraindications, followed by problems relating to injection technique, contrast material and MR imaging technique. For some of the aspects discussed, there is only little published evidence. Therefore, the article is based on the personal experience of the author and on local standards of procedures. Such standards, as well as medico-legal considerations, may vary from country to country. Contraindications for MR arthrography include pre-existing infection, reflex sympathetic dystrophy and possibly bleeding disorders, avascular necrosis and known allergy to contrast media. Errors in injection technique may lead to extra-articular collection of contrast agent or to contrast agent leaking from the joint space, which may cause diagnostic difficulties. Incorrect concentrations of contrast material influence image quality and may also lead to non-diagnostic examinations. Errors relating to MR imaging include delays between injection and imaging and inadequate choice of sequences. Potential solutions to the various possible errors are presented. (orig.)

  9. Magnetic Resonance Imaging (MRI): Brain (For Parents)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Magnetic Resonance Imaging (MRI): Brain KidsHealth / For Parents / Magnetic Resonance Imaging (MRI): Brain What's in this article? What ...

  10. Magnetic resonance imaging in neuroradiology

    International Nuclear Information System (INIS)

    Voigt, K.; Lotx, J.W.

    1990-01-01

    Magnetic resonance imaging (MRI) is now accepted as an effective method of investigating a wide range of disorders, especially of the brain and spine. A short introduction on image contrast in MRI is given and the advantages and disadvantages for the different diseases of the brain is discussed. Excellent soft-tissue contrast, multiplanar imaging capabilities and lack of ionising radiation are conspicuous advantages, and it is now established as the investigation of choice in a large number of clinical conditions, especially when the central nervous system is involved. However, it remains only one of a series of imaging modalities. A confident provisional clinical diagnosis is essential for establishing an imaging protocol and the intention should always be to reach a definitive diagnosis in the least invasive and most cost-effective way. 7 figs., 19 refs

  11. Fast MR arthrography using VIBE sequences to evaluate the rotator cuff

    Energy Technology Data Exchange (ETDEWEB)

    Vandevenne, Jan E. [Ziekenhuizen Oost-Limburg, Department of Radiology, Genk (Belgium); Universitair Ziekenhuis Antwerpen, University of Antwerp, Department of Radiology, Edegem (Belgium); Vanhoenacker, Filip; Parizel, Paul M. [Universitair Ziekenhuis Antwerpen, University of Antwerp, Department of Radiology, Edegem (Belgium); Mahachie John, Jestinah M. [University of Hasselt, Centre for Statistics, Diepenbeek (Belgium); Gelin, Geert [Ziekenhuizen Oost-Limburg, Department of Radiology, Genk (Belgium)

    2009-07-15

    The purpose of this paper was to evaluate if short volumetric interpolated breath-hold examination (VIBE) sequences can be used as a substitute for T1-weighted with fat saturation (T1-FS) sequences when performing magnetic resonance (MR) arthrography to diagnose rotator cuff tears. Eighty-two patients underwent direct MR arthrography of the shoulder joint using VIBE (acquisition time of 13 s) and T1-FS (acquisition time of 5 min) sequences in the axial and paracoronal plane on a 1.0-T MR unit. Two radiologists scored rotator cuff tendons on VIBE and T1-FS images separately as normal, small/large partial thickness and full thickness tears with or without geyser sign. T1-FS sequences were considered the gold standard. Surgical correlation was available in a small sample. Sensitivity, specificity, and positive and negative predictive values of VIBE were greater than 92% for large articular-sided partial thickness and full thickness tears. For detecting fraying and articular-sided small partial thickness tears, these parameters were 55%, 94%, 94%, and 57%, respectively. The simple kappa value was 0.76, and the weighted kappa value was 0.86 for agreement between T1-FS and VIBE scores. All large partial and full thickness tears at surgery were correctly diagnosed using VIBE or T1-FS MR images. Fast MR arthrography of the shoulder joint using VIBE sequences showed good concordance with the classically used T1-FS sequences for the appearance of the rotator cuff, in particular for large articular-sided partial thickness tears and for full thickness tears. Due to its very short acquisition time, VIBE may be especially useful when performing MR arthrography in claustrophobic patients or patients with a painful shoulder. (orig.)

  12. A study on usefulness of CT arthrography for the temporomandibular joint

    Energy Technology Data Exchange (ETDEWEB)

    Murakami, Shumei [Osaka Univ. (Japan). School of Dentistry

    1992-06-01

    In the field of orthopedics, CT arthrography has been utilized for the shoulder and the knee joints diagnosis. In this study, CT arthrography was applied to the temporomandibular joint (TMJ) and the usefulness of this method was evaluated experimentally and clinically. In the experimental study, CT, CT arthrography and arthrotomogtaphy were compared each other with serial section from human autopsy specimen. It was confirmed that arthrography was indispensable for diagnosis of the location and configuration of the articular disk. In the sagittal section, CT arthrography was almost equal to arthrotomography. But in the coronal section, CT arthrography proved to be advantageous to arthrotomography, because there were various blur images on the arthrotomographic images from the complex bony structures of the skull. In the clinical study, coronal CT arthrography was applied for the patients with internal derangements of the TMJ. The mesio-lateral displacement of the disk (62%), perforation of the attachment (23%), and the intra-articular adhesion (70%) could be diagnosed. BY CT arthrography, the mesio-lateral displacement of the disk was more clearly diagnosed and the intra-articular adhesions were proved with higher rate than by the arthrotomography. From this study, it was concluded that CT arthrography has an important role in diagnosis of the TMJ soft tissue. (author) 51 refs.

  13. Endometrial cancer: magnetic resonance imaging.

    Science.gov (United States)

    Manfredi, R; Gui, B; Maresca, G; Fanfani, F; Bonomo, L

    2005-01-01

    Carcinoma of the endometrium is the most common invasive gynecologic malignancy of the female genital tract. Clinically, patients with endometrial carcinoma present with abnormal uterine bleeding. The role of magnetic resonance imaging (MRI) in endometrial carcinoma is disease staging and treatment planning. MRI has been shown to be the most valuable imaging mod-ality in this task, compared with endovaginal ultrasound and computed tomography, because of its intrinsic contrast resolution and multiplanar capability. MRI protocol includes axial T1-weighted images; axial, sagittal, and coronal T2-weighted images; and dynamic gadolinium-enhanced T1-weighted imaging. MR examination is usually performed in the supine position with a phased array multicoil using a four-coil configuration. Endometrial carcinoma is isointense with the normal endometrium and myometrium on noncontrast T1-weighted images and has a variable appearance on T2-weighted images demonstrating heterogeneous signal intensity. The appearance of noninvasive endometrial carcinoma on MRI is characterized by a normal or thickened endometrium, with an intact junctional zone and a sharp tumor-myometrium interface. Invasive endometrial carcinoma is characterized disruption or irregularity of the junctional zone by intermediate signal intensity mass on T2-weighted images. Invasion of the cervical stroma is diagnosed when the low signal intensity cervical stroma is disrupted by the higher signal intensity endometrial carcinoma. MRI in endometrial carcinoma performs better than other imaging modalities in disease staging and treatment planning. Further, the accuracy and the cost of MRI are equivalent to those of surgical staging.

  14. Comparison of three dimensional isotropic and two dimensional conventional indirect MR arthrography for the diagnosis of rotator cuff tears

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ji Hyun; Yoon, Young Cheol; Kwon, Jong Won; Yoo, Jae Chul [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Cha, Jang Kyu [Dept. of Radiology, Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of); Jee, Suk Kyoung [Joeun Madi Hospital, Seoul (Korea, Republic of)

    2014-12-15

    To compare the accuracy between a three-dimensional (3D) indirect isotropic T1-weighted fast spin-echo (FSE) magnetic resonance (MR) arthrography and a conventional two-dimensional (2D) T1-weighted sequences of indirect MR arthrography for diagnosing rotator cuff tears. The study was approved by our Institutional Review Board. In total, 205 patients who had undergone indirect shoulder MR arthrography followed by arthroscopic surgery for 206 shoulders were included in this study. Both conventional 2D T1-weighted FSE sequences and 3D isotropic T1-weighted FSE sequence were performed in all patients. Two radiologists evaluated the images for the presence of full- or partial-thickness tears in the supraspinatus-infraspinatus (SSP-ISP) tendons and tears in the subscapularis (SSC) tendons. Using the arthroscopic findings as the reference standard, the diagnostic performances of both methods were analyzed by the area under the receiver operating characteristic curve (AUC). Arthroscopy confirmed 165 SSP-ISP tendon tears and 103 SSC tendon tears. For diagnosing SSP-ISP tendon tears, the AUC values were 0.964 and 0.989 for the 2D sequences and 3D T1-weighted FSE sequence, respectively, in reader I and 0.947 and 0.963, respectively, in reader II. The AUC values for diagnosing SSC tendon tears were 0.921 and 0.925, respectively, for reader I and 0.856 and 0.860, respectively, for reader II. There was no significant difference between the AUC values of the 2D and 3D sequences in either reader for either type of tear. 3D indirect isotropic MR arthrography with FSE sequence and the conventional 2D arthrography are not significantly different in terms of accuracy for diagnosing rotator cuff tears.

  15. Comparison of three dimensional isotropic and two dimensional conventional indirect MR arthrography for the diagnosis of rotator cuff tears

    International Nuclear Information System (INIS)

    Lee, Ji Hyun; Yoon, Young Cheol; Kwon, Jong Won; Yoo, Jae Chul; Cha, Jang Kyu; Jee, Suk Kyoung

    2014-01-01

    To compare the accuracy between a three-dimensional (3D) indirect isotropic T1-weighted fast spin-echo (FSE) magnetic resonance (MR) arthrography and a conventional two-dimensional (2D) T1-weighted sequences of indirect MR arthrography for diagnosing rotator cuff tears. The study was approved by our Institutional Review Board. In total, 205 patients who had undergone indirect shoulder MR arthrography followed by arthroscopic surgery for 206 shoulders were included in this study. Both conventional 2D T1-weighted FSE sequences and 3D isotropic T1-weighted FSE sequence were performed in all patients. Two radiologists evaluated the images for the presence of full- or partial-thickness tears in the supraspinatus-infraspinatus (SSP-ISP) tendons and tears in the subscapularis (SSC) tendons. Using the arthroscopic findings as the reference standard, the diagnostic performances of both methods were analyzed by the area under the receiver operating characteristic curve (AUC). Arthroscopy confirmed 165 SSP-ISP tendon tears and 103 SSC tendon tears. For diagnosing SSP-ISP tendon tears, the AUC values were 0.964 and 0.989 for the 2D sequences and 3D T1-weighted FSE sequence, respectively, in reader I and 0.947 and 0.963, respectively, in reader II. The AUC values for diagnosing SSC tendon tears were 0.921 and 0.925, respectively, for reader I and 0.856 and 0.860, respectively, for reader II. There was no significant difference between the AUC values of the 2D and 3D sequences in either reader for either type of tear. 3D indirect isotropic MR arthrography with FSE sequence and the conventional 2D arthrography are not significantly different in terms of accuracy for diagnosing rotator cuff tears.

  16. Multidimensionally encoded magnetic resonance imaging.

    Science.gov (United States)

    Lin, Fa-Hsuan

    2013-07-01

    Magnetic resonance imaging (MRI) typically achieves spatial encoding by measuring the projection of a q-dimensional object over q-dimensional spatial bases created by linear spatial encoding magnetic fields (SEMs). Recently, imaging strategies using nonlinear SEMs have demonstrated potential advantages for reconstructing images with higher spatiotemporal resolution and reducing peripheral nerve stimulation. In practice, nonlinear SEMs and linear SEMs can be used jointly to further improve the image reconstruction performance. Here, we propose the multidimensionally encoded (MDE) MRI to map a q-dimensional object onto a p-dimensional encoding space where p > q. MDE MRI is a theoretical framework linking imaging strategies using linear and nonlinear SEMs. Using a system of eight surface SEM coils with an eight-channel radiofrequency coil array, we demonstrate the five-dimensional MDE MRI for a two-dimensional object as a further generalization of PatLoc imaging and O-space imaging. We also present a method of optimizing spatial bases in MDE MRI. Results show that MDE MRI with a higher dimensional encoding space can reconstruct images more efficiently and with a smaller reconstruction error when the k-space sampling distribution and the number of samples are controlled. Copyright © 2012 Wiley Periodicals, Inc.

  17. MR imaging of the shoulder

    International Nuclear Information System (INIS)

    Fritts, H.M.; Craig, E.; Kyle, R.; Strefling, M.; Miller, D.; Heithoff, K.; Schellhas, K.

    1988-01-01

    Magnetic resonance (MR) imaging (1.5-T unit) was performed in over 600 shoulders to evaluate shoulder pain. Ultrasound (US) and arthrography were performed in over 100 patients. Surgery was performed in over 75 patients. MR imaging offers information not well evaluated with other modalities, including bony impingement, tendinitis, bursitis, and osseous abnormalities, such as primary arthritis, avascular necrosis, occult fractures, and tumors. US and MR findings correlate well with surgical findings for medium to large rotator cuff tears. MR imaging with T2 weighting is superior for differentiating small tears from associated tendinitis. An algorithm for cost-effective shoulder imaging integrating US, MR imaging, arthrography, and computed tomographic arthrography are presented

  18. Scatter radiation exposure during knee arthrography

    International Nuclear Information System (INIS)

    Light, M.C.; Molloi, S.Y.; Yandow, D.R.; Ranallo, F.N.

    1987-01-01

    Knee arthrography, as performed at the authors' institution, was simulated and scattered radiation exposure to a radiologist's gonads, thyroid, and eye lens was measured with a sensitive ionization chamber. Results show that radiologists who regularly conduct knee arthrography examinations can incur doses to the gonads that are less than 6% of the U.S. limits, and to the thyroid and eye that are approximately 10% of the U.S. limits. Since the scatter radiation from overhead imaging of stress views constituted most (greater than or equal to 60%) of the dose to the lens of the eye and the thyroid, spot imaging was evaluated as a substitute for overhead imaging in the assessment of the anterior cruciate ligament. This substitution resulted in no loss of clinical information and has now completely replaced overhead imaging of stress views at this institution

  19. Feasibility and preliminary results of SPECT/CT arthrography of the wrist in comparison with MR arthrography in patients with suspected ulnocarpal impaction

    Energy Technology Data Exchange (ETDEWEB)

    Strobel, Klaus [Lucerne Cantonal Hospital, Department of Nuclear Medicine and Radiology, Lucerne (Switzerland); Kantonsspital Luzern, Roentgeninstitut/Nuklearmedizin, Luzern (Switzerland); Steurer-Dober, Isabelle; Huellner, Martin W.; Sol Perez Lago, Maria del; Veit-Haibach, Patrick; Tornquist, Katharina [Lucerne Cantonal Hospital, Department of Nuclear Medicine and Radiology, Lucerne (Switzerland); Silva, Angela J. da [Advanced Molecular Imaging, Philips Healthcare, San Jose, CA (United States); Bodmer, Elvira; Wartburg, Urs von; Hug, Urs [Lucerne Cantonal Hospital, Division of Hand and Plastic Surgery, Lucerne (Switzerland)

    2014-03-15

    To evaluate the feasibility and performance of SPECT/CT arthrography of the wrist in comparison with MR arthrography in patients with suspected ulnocarpal impaction. This prospective study included 28 wrists of 27 patients evaluated with SPECT/CT arthrography and MR arthrography. Iodine contrast medium and gadolinium were injected into the distal radioulnar and midcarpal joints. Late-phase SPECT/CT was performed 3.5 h after intravenous injection of approximately 650 MBq {sup 99m}Tc-DPD. MR and SPECT/CT images were separately reviewed in relation to bone marrow oedema, radionuclide uptake, and tears in the scapholunate (SL) and lunotriquetral (LT) ligaments and triangular fibrocartilage complex (TFCC), and an overall diagnosis of ulnar impaction. MR, CT and SPECT/CT imaging findings were compared with each other, with the surgical findings in 12 patients and with clinical follow-up. The quality of MR arthrography and SPECT/CT arthrography images was fully diagnostic in 23 of 28 wrists (82 %) and 25 of 28 wrists (89 %), respectively. SPECT/CT arthrography was not diagnostic for ligament lesions due to insufficient intraarticular contrast in one wrist. MR and SPECT/CT images showed concordant findings regarding TFCC lesions in 22 of 27 wrists (81 %), SL ligament in 22 of 27 wrists (81 %) and LT ligament in 23 of 27 wrists (85 %). Bone marrow oedema on MR images and scintigraphic uptake were concordant in 21 of 28 wrists (75 %). MR images showed partial TFCC defects in four patients with normal SPECT/CT images. MR images showed bone marrow oedema in 4 of 28 wrists (14 %) without scintigraphic uptake, and scintigraphic uptake was present without MR bone marrow oedema in three wrists (11 %). Regarding diagnosis of ulnar impaction the concordance rate between CT and SPECT/CT was 100 % and reached 96 % (27 of 28) between MR and SPECT/CT arthrography. The sensitivity and specificity of MR, CT and SPECT/CT arthrography were 93 %, 100 % and 100 %, and 93 %, 93 % and 93

  20. The Usefulness of Dynamic Cine-Arthrography for Wrist Instability as Correlated with Arthroscopic Palmer Classification

    Energy Technology Data Exchange (ETDEWEB)

    Kim TaeYeon; Lee, Guen Young; Kim, Baek Hyun; Park, Jong Woong; Seo, Bo Kyoung; Cha, Sang Hoon [Korea University Ansan Hospital, Korea University College of Medicine, Ansan (Korea, Republic of)

    2011-05-15

    To introduce dynamic cine-arthrography and compare it with MR arthrography in the diagnosis of intrinsic ligament and triangular fibrocartilage complex tears, based on arthroscopic findings. A total of thirty-eight wrists of 38 patients who had undergone both dynamic cine-arthrography and MR arthrography were enrolled. Dynamic cinearthrography was performed after puncture of the radiocarpal joint by slow injection of contrast under continuous fluoroscopic guidance during passive wrist exercise. We obtained 1.5- or 3-T MR arthrography with fat-suppressed T1-weighted coronal and axial images. We evaluated scapholunate and lunotriquetral ligaments and triangular fibrocartilage complex tears according to the Palmer classification system. Based on the arthroscopic findings, we compared the diagnostic values between the two examinations using Kappa values. The overall sensitivity and specificity of diagnosis of intrinsic ligament tears was similar between dynamic cine-arthrography and MR arthrography (scapholunate ligament: sensitivity 66.7% vs. 80%, specificity 100% vs. 95.7%, lunotriquetral ligament: sensitivity 75.0% vs. 75.0%, specificity 94.1% vs. 91.2%). For triangular fibrocartilage complex tears, all diagnostic values were the same (sensitivity 96.4%, specificity 100%). The inter-examination agreement was substantial to perfect (kappa value 1.000). Dynamic cine-arthrography is valuable in the diagnosis of intrinsic ligament and triangular fibrocartilage complex tears compared to MR arthrography.

  1. MR arthrography of the shoulder: possible indications for clinical use; Einsatzmoeglichkeiten der MR-Arthrographie bei Erkrankungen des Schultergelenkes

    Energy Technology Data Exchange (ETDEWEB)

    Kreitner, K.F. [Mainz Univ. (Germany). Klinik mit Poliklinik fuer Radiologie; Grebe, P. [Mainz Univ. (Germany). Klinik mit Poliklinik fuer Radiologie; Kersjes, W. [Mainz Univ. (Germany). Klinik mit Poliklinik fuer Radiologie; Runkel, M. [Mainz Univ. (Germany). Klinik fuer Unfallchirurgie; Kirschner, P. [Elisabeth-Hospital, Mainz (Germany). Abt. fuer Unfall- und Wiederherstellungschirurgie St. Vincenz; Schild, H.H. [Mainz Univ. (Germany). Klinik mit Poliklinik fuer Radiologie

    1994-02-01

    In a prospective study possible indications for MR arthrography of the shoulder were evaluated. 37 patients were examined before and after intraarticular administration of a 2-mmolar solution of Gd-DTPA. MR arthrography was performed if there was no joint effusion and/or an uncertain finding concerning the rotator cuff or the capsulolabral complex on plain MR images. MR arthrography leads to a better demonstration of labrum pathology in 11/22 patients and to a superior delineation of the capsuloligamentous apparatus in 20/22 cases. In 9/15 patients with impingement lesions MR arthrography allowed a differentiation of severe tendinitis from partial and small full-thickness tears of the rotator cuff. MR arthrography of the shoulder joint enhances the accuracy of MR in case of an uncertain finding on plain MR images. (orig.) [Deutsch] In einer prospektiven Studie sollten Einsatzmoeglichkeiten der MR-Arthrographie bei Erkrankungen des Schultergelenkes herausgearbeitet werden. 37 Patienten wurden sowohl nativ als auch nach intraartikulaerer Gabe einer 2mmolaren Gd-DTPA-Loesung untersucht. Voraussetzungen fuer die KM-Gabe waren ein fehlender Gelenkerguss und/oder ein unklarer Befund des Labrum-Kapsel-Komplexes oder der Rotatorenmanschette in der Nativuntersuchung. Durch die MR-Arthrographie wurde bei 11/22 Patienten eine verbesserte Darstellung der Labrumpathologie erzielt; in 20/22 Faellen ergabe sich eine zuverlaessige Beurteilung der Gelenkkapsel. Bei 9/15 Patienten mit Erkrankungen der Rotatorenmanschette konnten Tendinitiden von partiellen und kleinen kompletten Rotatorenmanschettenrupturen sicher differenziert werden. Die MR-Arthrographie des Schultergelenkes fuehrt bei nicht eindeutigen Befunden in der Nativuntersuchung zu einer verbesserten Treffsicherheit der MR-Diagnostik. (orig.)

  2. Articular cartilage defect detectability in human knees with MR-arthrography

    International Nuclear Information System (INIS)

    Engel, A.; Kramer, J.; Stiglbauer, R.; Hajek, P.C.; Imhof, H.

    1993-01-01

    One hundred and thirteen knee joints were examined, of which 48 showed damage of the hyaline cartilage in one or more locations. For the evaluation of the magnetic resonance (MR) arthrographic images we used the macroscopic staging according to Outerbridge, the defect staging according to Bauer, as well as a new MR-arthrographic staging. The results of the evaluation were compared with the surgical findings in 61 knee joints. This revealed a sensitivity of 86 %, a specificity of 100 % and accuracy of 90 %. All lesions that could not be classified on MR-arthrography were of stage-I chondromalacia. (orig.)

  3. Articular cartilage defect detectability in human knees with MR-arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Engel, A. [Orthopaedic Clinic, Univ. of Vienna (Austria); Kramer, J. [MR-Inst., Univ. of Vienna (Austria); Stiglbauer, R. [MR-Inst., Univ. of Vienna (Austria); Hajek, P.C. [MR-Inst., Univ. of Vienna (Austria); Imhof, H. [MR-Inst., Univ. of Vienna (Austria)

    1993-04-01

    One hundred and thirteen knee joints were examined, of which 48 showed damage of the hyaline cartilage in one or more locations. For the evaluation of the magnetic resonance (MR) arthrographic images we used the macroscopic staging according to Outerbridge, the defect staging according to Bauer, as well as a new MR-arthrographic staging. The results of the evaluation were compared with the surgical findings in 61 knee joints. This revealed a sensitivity of 86 %, a specificity of 100 % and accuracy of 90 %. All lesions that could not be classified on MR-arthrography were of stage-I chondromalacia. (orig.)

  4. Quantitative perfusion imaging in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Zoellner, F.G.; Gaa, T.; Zimmer, F.; Ong, M.M.; Riffel, P.; Hausmann, D.; Schoenberg, S.O.; Weis, M.

    2016-01-01

    Magnetic resonance imaging (MRI) is recognized for its superior tissue contrast while being non-invasive and free of ionizing radiation. Due to the development of new scanner hardware and fast imaging techniques during the last decades, access to tissue and organ functions became possible. One of these functional imaging techniques is perfusion imaging with which tissue perfusion and capillary permeability can be determined from dynamic imaging data. Perfusion imaging by MRI can be performed by two approaches, arterial spin labeling (ASL) and dynamic contrast-enhanced (DCE) MRI. While the first method uses magnetically labelled water protons in arterial blood as an endogenous tracer, the latter involves the injection of a contrast agent, usually gadolinium (Gd), as a tracer for calculating hemodynamic parameters. Studies have demonstrated the potential of perfusion MRI for diagnostics and also for therapy monitoring. The utilization and application of perfusion MRI are still restricted to specialized centers, such as university hospitals. A broad application of the technique has not yet been implemented. The MRI perfusion technique is a valuable tool that might come broadly available after implementation of standards on European and international levels. Such efforts are being promoted by the respective professional bodies. (orig.) [de

  5. Magnetic resonance imaging of Parkinsonism

    International Nuclear Information System (INIS)

    Mukai, Eiichiro; Makino, Naoki; Fujishiro, Kenichiro.

    1989-01-01

    We have analyzed magnetic resonance images in 33 patients; 18 patients with Parkinson's disease, 1 patient with diurnally fluctuating progressive dystonia, 1 patient with pure akinesia, 6 patients with multiple system atrophy, 1 patient with flunarizine induced parkinsonism, and 4 patients with unclassified parkinsonism. The MR images were obtained using a 1.5-T GE MR System. A spin-echo pulse sequence was used with a TE of 30 msec and 80 msec and a TR of 2000 msec. No signal abnormalities were seen in any patient with Parkinson's disease but 3 showed slightly decreased signal intensity of the putamen on T2-weighted sequences. Patients with diurnally fluctuating progressive dystonia and pure akinesia evidensed no abnormal findings. All six patients with multiple system atrophy demonstrated decreased signal intensity of the putamen, particularly along their lateral and posterior portions, and an enlarged substantia nigra. Atrophy of the pons and cerebellum was detected in all cases with multiple system atrophy. One case of flunarizine induced parkinsonism showed slightly decreased signal intensity of the putamen. Four cases of unclassified parkinsonism showed decreased signal in the putamen on T2-weighted sequences. Magnetic resonance imaging has the potential to become a useful diagnostic tool in the management of parkinsonism. (author)

  6. Magnetic resonance imaging of Parkinsonism

    Energy Technology Data Exchange (ETDEWEB)

    Mukai, Eiichiro [National Hospital of Nagoya (Japan); Makino, Naoki; Fujishiro, Kenichiro

    1989-06-01

    We have analyzed magnetic resonance images in 33 patients; 18 patients with Parkinson's disease, 1 patient with diurnally fluctuating progressive dystonia, 1 patient with pure akinesia, 6 patients with multiple system atrophy, 1 patient with flunarizine induced parkinsonism, and 4 patients with unclassified parkinsonism. The MR images were obtained using a 1.5-T GE MR System. A spin-echo pulse sequence was used with a TE of 30 msec and 80 msec and a TR of 2000 msec. No signal abnormalities were seen in any patient with Parkinson's disease but 3 showed slightly decreased signal intensity of the putamen on T2-weighted sequences. Patients with diurnally fluctuating progressive dystonia and pure akinesia evidensed no abnormal findings. All six patients with multiple system atrophy demonstrated decreased signal intensity of the putamen, particularly along their lateral and posterior portions, and an enlarged substantia nigra. Atrophy of the pons and cerebellum was detected in all cases with multiple system atrophy. One case of flunarizine induced parkinsonism showed slightly decreased signal intensity of the putamen. Four cases of unclassified parkinsonism showed decreased signal in the putamen on T2-weighted sequences. Magnetic resonance imaging has the potential to become a useful diagnostic tool in the management of parkinsonism. (author).

  7. Magnetic resonance imaging of chemistry.

    Science.gov (United States)

    Britton, Melanie M

    2010-11-01

    Magnetic resonance imaging (MRI) has long been recognized as one of the most important tools in medical diagnosis and research. However, MRI is also well placed to image chemical reactions and processes, determine the concentration of chemical species, and look at how chemistry couples with environmental factors, such as flow and heterogeneous media. This tutorial review will explain how magnetic resonance imaging works, reviewing its application in chemistry and its ability to directly visualise chemical processes. It will give information on what resolution and contrast are possible, and what chemical and physical parameters can be measured. It will provide examples of the use of MRI to study chemical systems, its application in chemical engineering and the identification of contrast agents for non-clinical applications. A number of studies are presented including investigation of chemical conversion and selectivity in fixed-bed reactors, temperature probes for catalyst pellets, ion mobility during tablet dissolution, solvent dynamics and ion transport in Nafion polymers and the formation of chemical waves and patterns.

  8. Magnetic resonance imaging in psychiatry

    International Nuclear Information System (INIS)

    Mann, K.

    1993-01-01

    Diagnosis and research in psychiatry are increasingly availing themselves of magnetic resonance imaging (MRI). In comparison to computed tomography (CT), this offers the combined benefits of no exposure to radiation, high resolution, artefact-free display of structures near bone, and a sharp contrast between the grey and white brain matter, with freedom to select the section. With the exception of very anxious patients, MRI will gradually replace CT scans for a wide range of differential diagnostic investigations. Its superiority in systematic studies of psychiatric patients with discrete cerebral parenchyma lesions is already considered proven. This is illustrated on the basis of research into schizophrenia and alcoholism. (orig.) [de

  9. Anterior approach for knee arthrography

    International Nuclear Information System (INIS)

    Zurlo, J.V.; Towers, J.D.; Golla, S.

    2001-01-01

    Objective. To develop a new method of magnetic resonance arthrography (MRA) of the knee using an anterior approach analogous to the portals used for knee arthroscopy.Design. An anterior approach to the knee joint was devised mimicking anterior portals used for knee arthroscopy. Seven patients scheduled for routine knee MRA were placed in a decubitus position and under fluoroscopic guidance a needle was advanced from a position adjacent to the patellar tendon into the knee joint. After confirmation of the needle tip location, a dilute gadolinium solution was injected.Results and conclusion. All the arthrograms were technically successful. The anterior approach to knee MRA has greater technical ease than the traditional approach with little patient discomfort. (orig.)

  10. Magnetic resonance imaging of hypophysis

    International Nuclear Information System (INIS)

    Malla Huesh, I. V.

    2016-01-01

    Hypothalamic-pituitary diseases represent with wide variety of symptoms in regard with changes in the endocrine function. Magnetic resonance imaging has a crucial role in detecting the morphologic appearance in physiologic conditions, malformative diseases and acquired pathologies. The MR-imaging is established as the method of choice in assessing the changes in the hypothalamic-pituitary axis. The pituitary gland is a complex structure with an important role in the homeostasis of the organism even though it is so small? It is surrounded by bony structures, vessels, nerves and the brain parenchyma. It consists of three parts - anterior called - adenohypophysis, posterior - neurohypophysis and pituitary stalk. The anterior part comprises about 75% of the gland. Computed tomography (CT) has a limited role in detecting the pituitary gland. It is mainly used in cases of elevated intracranial pressure due to suspected apoplexy. The gland's small size, relation to other structures and its soft tissue characteristic make it an accessible region of interest for detecting with MR-imaging. The lack of ionizing energy and the technical advances in the MR-methods are responsible for the creating images with better spatial resolution and signal to noise ratio. The examination is carried out on a standard protocol. It is important that thin slices are executed in sagittal and coronal planes. Performing a sequence, regarding the brain parenchyma is essential, since many malformations of the pituitary gland are associated with other congenital conditions. The examination starts with a T1W sequence to assess the normal anatomic condition of the gland. The intensity of the adenohypophysis is compared to the one in the pons. It is hypointense, whereas the neurohypophysis is hyperintense, due to the lipid neurosecretory granules transported along the hypothalamic-pituitary axis. T2W-images in coronal plane are used to evaluate the hypothalamus, pituitary stalk, optic chiasm, olfactory

  11. Fetal abdominal magnetic resonance imaging

    International Nuclear Information System (INIS)

    Brugger, Peter C.; Prayer, Daniela

    2006-01-01

    This review deals with the in vivo magnetic resonance imaging (MRI) appearance of the human fetal abdomen. Imaging findings are correlated with current knowledge of human fetal anatomy and physiology, which are crucial to understand and interpret fetal abdominal MRI scans. As fetal MRI covers a period of more than 20 weeks, which is characterized not only by organ growth, but also by changes and maturation of organ function, a different MR appearance of the fetal abdomen results. This not only applies to the fetal intestines, but also to the fetal liver, spleen, and adrenal glands. Choosing the appropriate sequences, various aspects of age-related and organ-specific function can be visualized with fetal MRI, as these are mirrored by changes in signal intensities. Knowledge of normal development is essential to delineate normal from pathological findings in the respective developmental stages

  12. Fetal abdominal magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Brugger, Peter C. [Center of Anatomy and Cell Biology, Integrative Morphology Group, Medical University of Vienna, Waehringerstrasse 13, 1090 Vienna (Austria)]. E-mail: peter.brugger@meduniwien.ac.at; Prayer, Daniela [Department of Radiology, Medical University of Vienna, Waehringerguertel 18-20, 1090 Vienna (Austria)

    2006-02-15

    This review deals with the in vivo magnetic resonance imaging (MRI) appearance of the human fetal abdomen. Imaging findings are correlated with current knowledge of human fetal anatomy and physiology, which are crucial to understand and interpret fetal abdominal MRI scans. As fetal MRI covers a period of more than 20 weeks, which is characterized not only by organ growth, but also by changes and maturation of organ function, a different MR appearance of the fetal abdomen results. This not only applies to the fetal intestines, but also to the fetal liver, spleen, and adrenal glands. Choosing the appropriate sequences, various aspects of age-related and organ-specific function can be visualized with fetal MRI, as these are mirrored by changes in signal intensities. Knowledge of normal development is essential to delineate normal from pathological findings in the respective developmental stages.

  13. Magnetic resonance imaging of the prostate

    DEFF Research Database (Denmark)

    Iversen, P; Kjaer, L; Thomsen, C

    1988-01-01

    Magnetic resonance imaging offers new possibilities in investigation of the prostate gland. Current results of imaging and tissue discrimination in the evaluation of prostatic disease are reviewed. Magnetic resonance imaging may be useful in the staging of carcinoma of the prostate....

  14. Magnetic resonance imaging of the prostate

    DEFF Research Database (Denmark)

    Iversen, P; Kjaer, L; Thomsen, C

    1987-01-01

    Magnetic resonance imaging offers new possibilities in the investigation of the prostate. The current results of imaging and tissue discrimination in the evaluation of prostatic disease are reviewed. Magnetic resonance imaging may be of value in the staging of carcinoma of the prostate....

  15. Value of knee joint arthrography

    International Nuclear Information System (INIS)

    Luzsa, Gyoergy; Kiss Toth, Peter

    1985-01-01

    On the basis of the literature and the analysis of 204 examinations, the method and clinical application of knee joint arthrography are reviewed. 50 out of the 54 operated cases were perfectly diagnosed. The double contrast knee joint arthrography can be applied to detect meniscus changes, popliteal cysts, synovial disorders and chondral defects. The effectiveness of arthrography and arthroscopy was compared and the introduction of the former in each county seat is suggested. (author)

  16. Presurgical functional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Stippich, C.

    2010-01-01

    Functional magnetic resonance imaging (fMRI) is an important and novel neuroimaging modality for patients with brain tumors. By non-invasive measurement, localization and lateralization of brain activiation, most importantly of motor and speech function, fMRI facilitates the selection of the most appropriate and sparing treatment and function-preserving surgery. Prerequisites for the diagnostic use of fMRI are the application of dedicated clinical imaging protocols and standardization of the respective imaging procedures. The combination with diffusion tensor imaging (DTI) also enables tracking and visualization of important fiber bundles such as the pyramidal tract and the arcuate fascicle. These multimodal MR data can be implemented in computer systems for functional neuronavigation or radiation treatment. The practicability, accuracy and reliability of presurgical fMRI have been validated by large numbers of published data. However, fMRI cannot be considered as a fully established modality of diagnostic neuroimaging due to the lack of guidelines of the responsible medical associations as well as the lack of medical certification of important hardware and software components. This article reviews the current research in the field and provides practical information relevant for presurgical fMRI. (orig.) [de

  17. Arthrography of the biceps tendon

    International Nuclear Information System (INIS)

    Ahovuo, J.; Linden, H.; Hovi, I.; Paavolainen, P.; Bjoerkenheim, J.M.

    1988-01-01

    The purpose of this study was to analyse the factors having an influence on the arthrographic imaging of the biceps tendon. The study comprised 174 patients suffering from chronic shoulder pain. They underwent conventional shoulder arthrography with sodium meglumine metrizoate or metrizamide as a contrast medium. In the patients with a full-thickness tear of the rotator cuff, the biceps tendon sheath failed to fill with contrast medium more often than in those with an intact tendinous cuff. Metrizamide filled the biceps tendon sheath more readily than sodium meglumine metrizoate in patients with a full-thickness tear of the ortator cuff. The volume of the contrast medium injected had no influence on the imaging of the biceps tendon. (orig.)

  18. Artifacts in Magnetic Resonance Imaging

    International Nuclear Information System (INIS)

    Krupa, Katarzyna; Bekiesińska-Figatowska, Monika

    2015-01-01

    Artifacts in magnetic resonance imaging and foreign bodies within the patient’s body may be confused with a pathology or may reduce the quality of examinations. Radiologists are frequently not informed about the medical history of patients and face postoperative/other images they are not familiar with. A gallery of such images was presented in this manuscript. A truncation artifact in the spinal cord could be misinterpreted as a syrinx. Motion artifacts caused by breathing, cardiac movement, CSF pulsation/blood flow create a ghost artifact which can be reduced by patient immobilization, or cardiac/respiratory gating. Aliasing artifacts can be eliminated by increasing the field of view. An artificially hyperintense signal on FLAIR images can result from magnetic susceptibility artifacts, CSF/vascular pulsation, motion, but can also be found in patients undergoing MRI examinations while receiving supplemental oxygen. Metallic and other foreign bodies which may be found on and in patients’ bodies are the main group of artifacts and these are the focus of this study: e.g. make-up, tattoos, hairbands, clothes, endovascular embolization, prostheses, surgical clips, intraorbital and other medical implants, etc. Knowledge of different types of artifacts and their origin, and of possible foreign bodies is necessary to eliminate them or to reduce their negative influence on MR images by adjusting acquisition parameters. It is also necessary to take them into consideration when interpreting the images. Some proposals of reducing artifacts have been mentioned. Describing in detail the procedures to avoid or limit the artifacts would go beyond the scope of this paper but technical ways to reduce them can be found in the cited literature

  19. Magnetic resonance arthrography assessment of the superior labrum using the BLC system: age-related changes mimicking SLAP-2 lesions

    International Nuclear Information System (INIS)

    Koziak, Adrian; Chuang, Michael J.; Jancosko, Jason J.; Nottage, Wesley M.; Burnett, Keith R.

    2014-01-01

    The purpose of the study was to describe the variation of the superior labrum with increasing age by assessing magnetic resonance (MR) arthrograms. Inclusion criteria were used to include only the MR arthrograms of patients devoid of clinical labral pathology. Two hundred thiry-six MR arthrograms were blindly assessed for biceps-labral complex (BLC) type 1-3 and sublabral recess size by a musculoskeletal radiologist. We have chosen the BLC system, which defines normal superior labral variants, since it is established in the literature and is used by reporting musculoskeletal (MSK) radiologists. The MR arthrograms demonstrated that the majority of patients <40 years old were BLC type 1 and showed a steady increase in BLC types 2 and 3 with increasing age. Assessments demonstrated significantly greater (p < 0.01) mean BLC types (1.62 vs 1.29) and recess size (1.35 vs 0.66 mm) in those over 40 compared with those less than 40 years of age. Furthermore, significant differences (p < 0.05) were noted between mean BLC assessments between different decades of age. There appears to be a physiologic deepening of the superior labrum sulcus with age, which becomes significant after the age of 40. These findings can contribute to whether the superior labrum is considered abnormal when assessed radiographically. The differentiation of normal age-related changes in the shoulder, from those of a type 2 SLAP tear can reduce the rates of unnecessary SLAP-2 repairs. This is the first reported series to use the BLC system; we believe it provides a common nomenclature to allow clear communication between specialists. (orig.)

  20. Magnetic resonance arthrography assessment of the superior labrum using the BLC system: age-related changes mimicking SLAP-2 lesions

    Energy Technology Data Exchange (ETDEWEB)

    Koziak, Adrian [Queen' s School of Medicine, Kingston, Ontario (Canada); Chuang, Michael J.; Jancosko, Jason J.; Nottage, Wesley M. [The Sport Clinic Orthopedic Medical Associates, Inc., Laguna Hills, CA (United States); Burnett, Keith R. [Saddleback Valley Radiology, Laguna Hills, CA (United States)

    2014-08-15

    The purpose of the study was to describe the variation of the superior labrum with increasing age by assessing magnetic resonance (MR) arthrograms. Inclusion criteria were used to include only the MR arthrograms of patients devoid of clinical labral pathology. Two hundred thiry-six MR arthrograms were blindly assessed for biceps-labral complex (BLC) type 1-3 and sublabral recess size by a musculoskeletal radiologist. We have chosen the BLC system, which defines normal superior labral variants, since it is established in the literature and is used by reporting musculoskeletal (MSK) radiologists. The MR arthrograms demonstrated that the majority of patients <40 years old were BLC type 1 and showed a steady increase in BLC types 2 and 3 with increasing age. Assessments demonstrated significantly greater (p < 0.01) mean BLC types (1.62 vs 1.29) and recess size (1.35 vs 0.66 mm) in those over 40 compared with those less than 40 years of age. Furthermore, significant differences (p < 0.05) were noted between mean BLC assessments between different decades of age. There appears to be a physiologic deepening of the superior labrum sulcus with age, which becomes significant after the age of 40. These findings can contribute to whether the superior labrum is considered abnormal when assessed radiographically. The differentiation of normal age-related changes in the shoulder, from those of a type 2 SLAP tear can reduce the rates of unnecessary SLAP-2 repairs. This is the first reported series to use the BLC system; we believe it provides a common nomenclature to allow clear communication between specialists. (orig.)

  1. Endovascular interventional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Bartels, L W; Bakker, C J G

    2003-01-01

    Minimally invasive interventional radiological procedures, such as balloon angioplasty, stent placement or coiling of aneurysms, play an increasingly important role in the treatment of patients suffering from vascular disease. The non-destructive nature of magnetic resonance imaging (MRI), its ability to combine the acquisition of high quality anatomical images and functional information, such as blood flow velocities, perfusion and diffusion, together with its inherent three dimensionality and tomographic imaging capacities, have been advocated as advantages of using the MRI technique for guidance of endovascular radiological interventions. Within this light, endovascular interventional MRI has emerged as an interesting and promising new branch of interventional radiology. In this review article, the authors will give an overview of the most important issues related to this field. In this context, we will focus on the prerequisites for endovascular interventional MRI to come to maturity. In particular, the various approaches for device tracking that were proposed will be discussed and categorized. Furthermore, dedicated MRI systems, safety and compatibility issues and promising applications that could become clinical practice in the future will be discussed. (topical review)

  2. Myositis ossificans: magnetic resonance images

    International Nuclear Information System (INIS)

    Dosda, R.; Marti-Bonmati, L.; Concepcion, L.; Galant, J.

    1999-01-01

    Myositis ossificans is characterized by a benign, self-limiting, ossifying mass of the white tissue. In the present report, we describe the magnetic resonance (MR) images in three cases of myositis ossificans in pediatric patients, correlating the MR findings with those obtained with other radiological studies. The lesions were detected in three patients, two boys and one girl, ranging in age between 10 and 14 years. The nature of the lesion was confirmed histologically in all three cases. The MR images were obtained using superconductive units at 0.5 Teslas, with T1 and T2-weighted spin-echo and STIR sequences. In two patients, gadolinium-enhanced T1-weighted images were also obtained. As in any process of maturation, the proliferation/maturation ratio depends on the moment in the course of the lesion, which affects its MR features,. In acute phases, the soft tissue mass with an intraosseous, perilesional adematous reaction predominates, while annular calcification and lesser edema are characteristic of subacute episode. Myositis ossificans is very rare in children. The inflammatory response may present a radiological pattern difficult to distinguish from that of aggressive tumor or infection, especially in the acute phase. (Author) 7 refs

  3. Olfactometer for functional resonance imaging

    International Nuclear Information System (INIS)

    Andrieu, Patrice

    2013-01-01

    The Magnetic Resonance Imaging (fMRI) has been developing for twenty years. Indeed, the marketing of high-resolution MRI (5 Tesla and 7 Tesla recently) allowed the study of brain mechanisms. The research work of this PHD was to develop instrumentation for objective studies of brain behavior during a sensory stimulation. We are interested in the study of olfaction. We have designed and built a six-channel olfactometer, synchronized with breathing and controlled by computer. The originality of our work lies in the modularity of our device, which makes it adaptable to a wide range of studies. We also propose a new method to change the intensity of stimulation delivered: the Pulse Width Modulation (PWM). This device has been used in several studies in fMRI. The effectiveness of the PWM is highlighted in a psychophysical study described in this manuscript. (author)

  4. Shoulder instability syndrome: comparison of CT, arthrography and MR findings

    International Nuclear Information System (INIS)

    Ortiz, L.; Alcaraz, M.; Preciados, J.L.G.; Garcia Alvarez, A.; Castello, J.

    1995-01-01

    Currently, the two most reliable explorations for diagnosing the lesions that produce shoulder instability are computerized tomography with arthrography and magnetic resonance following intraarticular injection of gadolinium. Dynamic CT arthrography is considered the best method to assess these lesions; MR is a similar procedure but involves certain drawbacks, among them, its cost. The techniques applied in these explorations are reviewed, as are the anatomy of the different components of this joint and the radiological findings leading to a diagnosis of the pathology underlying its instability. (Author)

  5. Pocket atlas of cranial magnetic resonance imaging

    International Nuclear Information System (INIS)

    Haughton, V.M.; Daniels, D.L.

    1986-01-01

    This atlas illustrates normal cerebral anatomy in magnetic resonance images. From their studies in cerebral anatomy utilizing cryomicrotome and other techniques, the authors selected more than 100 high-resolution images that represent the most clinically useful scans

  6. Functional magnetic resonance imaging by visual stimulation

    International Nuclear Information System (INIS)

    Nishimura, Yukiko; Negoro, Kiyoshi; Morimatsu, Mitsunori; Hashida, Masahiro

    1996-01-01

    We evaluated functional magnetic resonance images obtained in 8 healthy subjects in response to visual stimulation using a conventional clinical magnetic resonance imaging system with multi-slice spin-echo echo planar imaging. Activation in the visual cortex was clearly demonstrated by the multi-slice experiment with a task-related change in signal intensity. In addition to the primary visual cortex, other areas were also activated by a complicated visual task. Multi-slice spin-echo echo planar imaging offers high temporal resolution and allows the three-dimensional analysis of brain function. Functional magnetic resonance imaging provides a useful noninvasive method of mapping brain function. (author)

  7. Magnetic resonance imaging of radiation optic neuropathy

    International Nuclear Information System (INIS)

    Zimmerman, C.F.; Schatz, N.J.; Glaser, J.S.

    1990-01-01

    Three patients with delayed radiation optic neuropathy after radiation therapy for parasellar neoplasms underwent magnetic resonance imaging. The affected optic nerves and chiasms showed enlargement and focal gadopentetate dimeglumine enhancement. The magnetic resonance imaging technique effectively detected and defined anterior visual pathway changes of radionecrosis and excluded the clinical possibility of visual loss because of tumor recurrence

  8. [Technique and value of direct MR arthrography applying articular distraction].

    Science.gov (United States)

    Becce, Fabio; Wettstein, Michael; Guntern, Daniel; Mouhsine, Elyazid; Palhais, Nuno; Theumann, Nicolas

    2010-02-24

    Direct MR arthrography has a better diagnostic accuracy than MR imaging alone. However, contrast material is not always homogeneously distributed in the articular space. Lesions of cartilage surfaces or intra-articular soft tissues can thus be misdiagnosed. Concomitant application of axial traction during MR arthrography leads to articular distraction. This enables better distribution of contrast material in the joint and better delineation of intra-articular structures. Therefore, this technique improves detection of cartilage lesions. Moreover, the axial stress applied on articular structures may reveal lesions invisible on MR images without traction. Based on our clinical experience, we believe that this relatively unknown technique is promising and should be further developed.

  9. Arthrography of the TMJ

    International Nuclear Information System (INIS)

    Jend, H.H.; Triebel, H.J.; Jend-Rossmann, I.; Hamburg Univ.

    1986-01-01

    Articular dysfunction of the TMJ with anterior displacement of the disc ('internal derangement') is an entity which has been separated from other types of the 'myofascial pain syndromes' and which can be treated conservatively or by surgery. Arthrography of the TMJ has contributed greatly to an understanding of normal and abnormal function and, in many cases, it can provide a diagnosis. On the basis of our experience with 80 investigations we discuss technical problems and the clinical indications. The indications for arthrography are in the pre-operative diagnosis, when clinical findings are uncertain, in order to demonstrate perforation, in order to confirm a suspected diagnosis and to assist in prosthetic treatment. (orig.) [de

  10. MR and MR arthrography to identify degenerative and posttraumatic diseases in the shoulder joint

    International Nuclear Information System (INIS)

    Lee, Shi-Uk; Lang, Philipp

    2000-01-01

    MR imaging provides a comprehensive evaluation of a wide spectrum of both intraarticular and extraarticular pathology of the shoulder. MR imaging enables the detection or exclusion of degenerative and posttraumatic diseases of the shoulder with a reasonable accuracy. MR arthrography is useful in the visualization of subtle anatomic details and further improves the differentiation. In this article, findings of MR imaging and MR arthrography of degenerative and posttraumatic shoulder diseases (impingement syndrome, rotator cuff tears, and glenohumeral instability) has been reviewed

  11. Diagnosis of lesions of the acetabular labrum, of the labral-chondral transition zone, and of the cartilage in femoroacetabular impingement: Correlation between direct magnetic resonance arthrography and hip arthroscopy.

    Science.gov (United States)

    Crespo Rodríguez, A M; de Lucas Villarrubia, J C; Pastrana Ledesma, M A; Millán Santos, I; Padrón, M

    2015-01-01

    To determine the sensitivity and accuracy of direct MR arthrography in the diagnosis of intra-articular lesions associated with femoroacetabular impingement. We used direct MR arthrography to study 51 patients with femoroacetabular impingement who underwent arthroscopic hip surgery. Surgery demonstrated 37 labral tears, 44 lesions in the labral-chondral transitional zone, and 40 lesions of the articular cartilage. We correlated the findings at preoperative direct MR arthrography with those of hip arthroscopy and calculated the sensitivity, specificity, positive predictive value, negative predictive value, and validity index for direct MR arthrography. The sensitivity and specificity of MR arthrography were 94.5% and 100%, respectively, for diagnosing labral tears, 100% and 87.5%, respectively, for diagnosing lesions of the labral-chondral transition zone, and 92.5% and 54.5%, respectively, for diagnosing lesions of the articular cartilage. The negative predictive value of MR arthrography for lesions of the labral-chondral transitional zone was 100%. MR arthrography accurately defined extensive lesions of the cartilage and the secondary osseous changes (the main factor in poor prognosis), although its diagnostic performance was not so good in small chondral lesions. In patients with femoroacetabular impingement, direct MR arthrography can adequately detect and characterize lesions of the acetabular labrum and of the labral-chondral transitional zone as well as extensive lesions of the articular cartilage and secondary osseous changes. Copyright © 2013 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  12. Magnetic resonance imaging of Parkinsonism

    International Nuclear Information System (INIS)

    Nakamura, Yusaku; Takahashi, Mitsuo; Kitaguchi, Masataka; Akaneya, Yukio; Mitui, Yoshiyuki; Tanaka, Hisashi

    1991-01-01

    We studied eighteen patients affected by Parkinsonism with symptoms of tremor, bradykinesia, or rigidity using magnetic resonance imaging (MRI). Patients ranged in age from 34 to 80 years (mean 62.8±11.6 years), and the duration of their disease had been 3.8±3.2 years. MRI examinations were performed with Shimazu and Siemens superconducting magnets, operating at 0.5 and 1.5 T magnetic fields, respectively. Both T 1 - and T 2 -weighted spin echo (SE) pulse sequences were used. In eight patients (44.4%), MRI demonstrated bilateral multiple lacunar infarction of the basal ganglia. The most common abnormality identified was multiple, bilateral lacunar infarcts in the lateral portion of the putamen. The average size of the lacunar infarction of the putamen was less than half that of the entire putamen. Patients with multiple lacunar infarction were significantly older than the other patients and had lower Yahr's scores. The clinical symptoms of patients with bilateral multiple lacunar infarction of the basal ganglia were compatible with the diagnosis of arteriosclerotic Parkinsonism of akinetic rigid type. It has been suggested that multiple lacunar infarction of the basal ganglia may have led to Parkinsonism in these patients. (author)

  13. Magnetic resonance imaging and neurolupus

    International Nuclear Information System (INIS)

    Schott, A.M.; Colson, F.; Tebib, J.; Noel, E.; Bouvier, M.

    1990-01-01

    Magnetic resonance imaging (MRI) was assessed in the management of neuropsychiatric manifestations occurring in 6 SLE patients. The MRI scans were normal in 3 cases and was associated with remission of the symptoms except for a patient who experienced a chorea at the time of the examination. Abnormal MRI scans always revealed more lesions than CT scan. 2 different patterns of abnormalities seem to correspond to 2 specific disorders. In 2 patients with clinical presentation suggesting a cortical ischemia by vascular thrombosis, both MRI scans showed areas of abnormal high signal intensities located in the subcortical white matter. In one last patient, MRI scan revealed multiple focal areas of high signal intensities (on T 1 weighter scans) disseminated not only in the deep white matter but also in the gray one. These lesions could be depend upon demyelinisation which may occur by a local vascular process. This serie confirms the interest of MRI in the management of SLE brain involvement as well as it points out some problem of interpretation. This suggest further comparative studies especially at the real onset and during the course of neuro-psychiatric manifestations. At last, the coronal sections may be more informative for the diagnosis and patholophysiology than the horizontal ones [fr

  14. Nuclear magnetic resonance imaging method

    International Nuclear Information System (INIS)

    Johnson, G.; MacDonald, J.; Hutchison, S.; Eastwood, L.M.; Redpath, T.W.T.; Mallard, J.R.

    1984-01-01

    A method of deriving three dimensional image information from an object using nuclear magnetic resonance signals comprises subjecting the object to a continuous, static magnetic field and carrying out the following set of sequential steps: 1) exciting nuclear spins in a selected volume (90deg pulse); 2) applying non-aligned first, second and third gradients of the magnetic field; 3) causing the spins to rephase periodically by reversal of the first gradient to produce spin echoes, and applying pulses of the second gradient prior to every read-out of an echo signal from the object, to differently encode the spin in the second gradient direction for each read-out signal. The above steps 1-3 are then successively repeated with different values of gradient of the third gradient, there being a recovery interval between the repetition of successive sets of steps. Alternate echoes only are read out, the other echoes being time-reversed and ignored for convenience. The resulting signals are appropriately sampled, set out in an array and subjected to three dimensional Fourier transformation. (author)

  15. Wrist arthrography: a simple method

    Energy Technology Data Exchange (ETDEWEB)

    Berna-Serna, Juan D.; Reus, Manuel; Alonso, Jose [Virgen de la Arrixaca University Hospital, Department of Radiology, El Palmar (Murcia) (Spain); Martinez, Francisco; Domenech-Ratto, Gines [University of Murcia, Department of Human Anatomy, Faculty of Medicine, Murcia (Spain)

    2006-02-01

    A technique of wrist arthrography is presented using an adhesive marker-plate with radiopaque coordinates to identify precisely sites for puncture arthrography of the wrist and to obviate the need for fluoroscopic guidance. Radiocarpal joint arthrography was performed successfully in all 24 cases, 14 in the cadaveric wrists and 10 in the live patients. The arthrographic procedure described in this study is simple, safe, and rapid, and has the advantage of precise localisation of the site for puncture without need for fluoroscopic guidance. (orig.)

  16. Contrast agents in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Karadjian, V.

    1987-01-01

    The origine of nuclear magnetic resonance signal is reminded and different ways for contrast enhancement in magnetic resonance imaging are presented, especially, modifications of tissus relaxation times. Investigations have focused on development of agents incorporating either paramagnetic ions or stable free radicals. Pharmacological and toxicological aspects are developed. The diagnostic potential of these substances is illustrated by the example of gadolinium complexes [fr

  17. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... clear images. Patient movement can have the same effect. A very irregular heartbeat may affect the quality of images obtained using techniques that time the imaging based on the electrical activity of ...

  18. Can magnetic resonance imaging differentiate undifferentiated arthritis?

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Duer, Anne; Hørslev-Petersen, K

    2005-01-01

    A high sensitivity for the detection of inflammatory and destructive changes in inflammatory joint diseases makes magnetic resonance imaging potentially useful for assigning specific diagnoses, such as rheumatoid arthritis and psoriatic arthritis in arthritides, that remain undifferentiated after...... conventional clinical, biochemical and radiographic examinations. With recent data as the starting point, the present paper describes the current knowledge on magnetic resonance imaging in the differential diagnosis of undifferentiated arthritis....

  19. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... bear denotes child-specific content. Related Articles and Media MR Angiography (MRA) Magnetic Resonance, Functional (fMRI) - Brain ... the web pages found at these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | ...

  20. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... bear denotes child-specific content. Related Articles and Media Catheter Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's ( ... the web pages found at these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | ...

  1. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... immediately after the exam. A few patients experience side effects from the contrast material, including nausea and local ... Related Articles and Media Catheter Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's (Pediatric) CT (Computed Tomography) Magnetic ...

  2. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... or thyroid problems. Any of these conditions may influence the decision on whether contrast material will be ... bear denotes child-specific content. Related Articles and Media Catheter Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's ( ...

  3. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Related Articles and Media Catheter Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's (Pediatric) CT (Computed Tomography) Magnetic ... the possible charges you will incur. Web page review process: This Web page is reviewed regularly by ...

  4. Cerebral air embolism after arthrography of the ankle

    NARCIS (Netherlands)

    Müller, Marcella C. A.; Lagarde, Sjoerd M.; Germans, Menno R.; Juffermans, Nicole P.

    2010-01-01

    Background: The accidental migration of air from the venous circulation into the systemic arterial circulation is called paradoxical air embolism. This is a potential disastrous complication after diagnostic and surgical procedures. Arthrography has been a useful technique in joint imaging for the

  5. Magnetic resonance imaging: hazard, risk and safety

    International Nuclear Information System (INIS)

    Narayan, Pradeep; Suri, S.; Singh, P.

    2001-01-01

    The hazard and risk associated with magnetic resonance imaging is a matter of concern. In 1982, the Food and Drug Administration (FDA), USA issued guidelines to Hospital's Investigational Review Board (IRBs) in 'Guidelines for Evaluating Electromagnetic Exposure Risks for Trials of Clinical Nuclear Magnetic Resonance (NMR)'. In 1997, the Berufsgenossenschaft (BG), professional association for precision engineering and electronics of Germany, in their preliminary proposal for safety limits extended their concerns on static magnetic field. Owing to both time varying and static magnetic fields applied in Magnetic Resonance Imaging (MRI) this became of immediate concern to user community to assess the potential hazard and risk associated with the NMR system

  6. Supraspinatus tendon tears: comparison of US and MR arthrography with surgical correlation

    International Nuclear Information System (INIS)

    Ferrari, Francesco S.; Governi, Simone; Burresi, Francesca; Vigni, Francesco; Stefani, Paolo

    2002-01-01

    The aim of this study was to compare the diagnostic reliability of US with MR arthrography in diagnosing supraspinatus tendon tears. Surgical findings were used as the gold standard in detecting tears. A total of 44 patients were assessed with transverse and longitudinal US scans with respect to the long axis of the rotator cuff tendons and then examined with MR arthrography. This technique involved free-hand injection of contrast medium into the shoulder joint. At surgery 20 incomplete and 24 complete tears were observed. Ultrasound offered good results for the large tears, but its sensitivity decreased proportionally with the size of the tears. Magnetic resonance arthrography correctly diagnosed 43 tears, whereas only one false-negative diagnosis of tendinosis was made for a partial tear on the bursal side. Since it improves the diagnosis of small tears, MR arthrography must be performed on all patients for whom surgical repair is necessary in order to restore normal functions. (orig.)

  7. Supraspinatus tendon tears: comparison of US and MR arthrography with surgical correlation

    Energy Technology Data Exchange (ETDEWEB)

    Ferrari, Francesco S.; Governi, Simone; Burresi, Francesca; Vigni, Francesco; Stefani, Paolo [Department of Radiologic and Orthopaedic-Rehabilitative Sciences, University Hospital Siena (Italy)

    2002-05-01

    The aim of this study was to compare the diagnostic reliability of US with MR arthrography in diagnosing supraspinatus tendon tears. Surgical findings were used as the gold standard in detecting tears. A total of 44 patients were assessed with transverse and longitudinal US scans with respect to the long axis of the rotator cuff tendons and then examined with MR arthrography. This technique involved free-hand injection of contrast medium into the shoulder joint. At surgery 20 incomplete and 24 complete tears were observed. Ultrasound offered good results for the large tears, but its sensitivity decreased proportionally with the size of the tears. Magnetic resonance arthrography correctly diagnosed 43 tears, whereas only one false-negative diagnosis of tendinosis was made for a partial tear on the bursal side. Since it improves the diagnosis of small tears, MR arthrography must be performed on all patients for whom surgical repair is necessary in order to restore normal functions. (orig.)

  8. Arthrography of the ankle sprains

    International Nuclear Information System (INIS)

    Han, Moon Hee

    1985-01-01

    Ankle arthrography, by direct puncture of joint cavity, is considered to be a simple and accurate diagnostic method for a precise evaluation of ligamentous injury. Forty-seven cases of ankle arthrography were successively performed in the patients of acute ankle sprains. The purpose of this study is to demonstrate how ankle arthrography can delineate the pathologic anatomy in such cases. The results are as follows: 1. Thirty cases among forty seven revealed the findings of ligament tears. 2. For better diagnostic accuracy, the arthrography should be performed within 72 hrs. after injury. 3. The anterior talofibular ligament tears were the most common (twenty-nine cases) of all and seventeen of them revealed tears without association of any other ligament tears. 4. There were ten cases of calcaneofibular ligament tears and nine of them were associated with anterior talofibular ligament tears. 5. Three cases of anterior tibiofibular and one deltoid ligament tears were demonstrated

  9. Magnetic resonance imaging of the fetal brain.

    Science.gov (United States)

    Tee, L Mf; Kan, E Yl; Cheung, J Cy; Leung, W C

    2016-06-01

    This review covers the recent literature on fetal brain magnetic resonance imaging, with emphasis on techniques, advances, common indications, and safety. We conducted a search of MEDLINE for articles published after 2010. The search terms used were "(fetal OR foetal OR fetus OR foetus) AND (MR OR MRI OR [magnetic resonance]) AND (brain OR cerebral)". Consensus statements from major authorities were also included. As a result, 44 relevant articles were included and formed the basis of this review. One major challenge is fetal motion that is largely overcome by ultra-fast sequences. Currently, single-shot fast spin-echo T2-weighted imaging remains the mainstay for motion resistance and anatomical delineation. Recently, a snap-shot inversion recovery sequence has enabled robust T1-weighted images to be obtained, which is previously a challenge for standard gradient-echo acquisitions. Fetal diffusion-weighted imaging, diffusion tensor imaging, and magnetic resonance spectroscopy are also being developed. With multiplanar capabilities, superior contrast resolution and field of view, magnetic resonance imaging does not have the limitations of sonography, and can provide additional important information. Common indications include ventriculomegaly, callosum and posterior fossa abnormalities, and twin complications. There are safety concerns about magnetic resonance-induced heating and acoustic damage but current literature showed no conclusive evidence of deleterious fetal effects. The American College of Radiology guideline states that pregnant patients can be accepted to undergo magnetic resonance imaging at any stage of pregnancy if risk-benefit ratio to patients warrants that the study be performed. Magnetic resonance imaging of the fetal brain is a safe and powerful adjunct to sonography in prenatal diagnosis. It can provide additional information that aids clinical management, prognostication, and counselling.

  10. Arthrography of the ankle joint

    International Nuclear Information System (INIS)

    Crespi Porro, R.; Zellner, A.; Puricelli, G.; Quaglia, R.; Chelazzi, G.

    1984-01-01

    Arthrography of the ankle joint was first carried out by Johnson and Palmer at the Military Hospital in Stockholm in 1940. Arthrography can be used for judging the integrity of the articular cartilage, of osteochondritis dissecans, arthritis or adhesive capsulitis. The literature shows, however, that more than 95% of the patients on whom this examination has been performed has suffered from acute trauma. (orig.) [de

  11. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... you! Do you have a personal story about radiology? Share your patient story here Images × Image Gallery ... reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of North America ( ...

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... you! Do you have a personal story about radiology? Share your patient story here Images × Image Gallery ... reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of North America ( ...

  13. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... Imaging (MRI) procedure View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  14. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... six weeks) before being safe for MRI examinations. Examples include but are not limited to: artificial heart ... the area to be imaged. Furthermore, the examination takes longer than other imaging modalities (typically x-ray ...

  15. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... to a CD or uploaded to a digital cloud server. Currently, MRI is the most sensitive imaging ... over time. top of page What are the benefits vs. risks? Benefits MRI is a noninvasive imaging ...

  16. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... computer then processes the signals and generates a series of images, each of which shows a thin ... into the intravenous line (IV) after an initial series of scans. Additional series of images will be ...

  17. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... imaging modalities. top of page Additional Information and Resources RTAnswers.org : Radiation Therapy for Brain Tumors Radiation ... To locate a medical imaging or radiation oncology provider in your community, you can search the ACR- ...

  18. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... practice. top of page What are some common uses of the procedure? MR imaging of the head ... is done because a potential abnormality needs further evaluation with additional views or a special imaging technique. ...

  19. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... Most MRI exams are painless. However, some patients find it uncomfortable to remain still during MR imaging. ... anxious, confused or in severe pain, you may find it difficult to lie still during imaging. A ...

  20. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... determine the presence of certain diseases. The images can then be examined on a computer monitor, transmitted ... for imaging the joints and bones, where it can help: diagnose sports-related injuries detect the presence ...

  1. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... identify and accurately characterize diseases than other imaging methods. This detail makes MRI an invaluable tool in ... might be obscured by bone with other imaging methods. The contrast material used in MRI exams is ...

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... are clearer and more detailed than other imaging methods. This exam does not use ionizing radiation and ... clearer and more detailed than with other imaging methods. This detail makes MRI an invaluable tool in ...

  3. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... other imaging methods. This exam does not use ionizing radiation and may require an injection of a contrast ... other internal body structures. MRI does not use ionizing radiation (x-rays). Detailed MR images allow physicians to ...

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... claustrophobia. Newer open MRI units provide very high quality images for many types of exams. Older open MRI units may not provide this same image quality. Certain types of exams cannot be performed using ...

  5. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... claustrophobia. Newer open MRI units provide very high quality images for many types of exams; however, older ... MRI units may not provide this same image quality. Certain types of exams cannot be performed using ...

  6. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... a radiologist or other physician. To locate a medical imaging or radiation oncology provider in your community, you ... not provide cost information. The costs for specific medical imaging tests, treatments and procedures may vary by geographic ...

  7. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... a radiologist or other physician. To locate a medical imaging or radiation oncology provider in your community, you ... not provide cost information. The costs for specific medical imaging tests, treatments and procedures may vary by geographic ...

  8. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Detailed MR images allow physicians to evaluate various parts of the body and determine the presence of ... machine and in some cases, placed around the part of the body being imaged, send and receive ...

  9. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... metallic objects. Patient movement can have the same effect. A very irregular heartbeat may affect the quality of images obtained using techniques that time the imaging based on the electrical activity of ...

  10. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... based on clinical judgment. This is because traction devices and many types of life support equipment may distort the MR images and as a result, must be kept away from the area to be imaged. Furthermore, the examination takes longer than other imaging modalities (typically x-ray ...

  11. Magnetic resonance imaging in radiotherapy treatment planning

    NARCIS (Netherlands)

    Moerland, Marinus Adriaan

    1996-01-01

    From its inception in the early 1970's up to the present, magnetic resonance imaging (MRI) has evolved into a sophisticated technique, which has aroused considerable interest in var- ious subelds of medicine including radiotherapy. MRI is capable of imaging in any plane and does not use ionizing

  12. Automated Segmentation of Cardiac Magnetic Resonance Images

    DEFF Research Database (Denmark)

    Stegmann, Mikkel Bille; Nilsson, Jens Chr.; Grønning, Bjørn A.

    2001-01-01

    Magnetic resonance imaging (MRI) has been shown to be an accurate and precise technique to assess cardiac volumes and function in a non-invasive manner and is generally considered to be the current gold-standard for cardiac imaging [1]. Measurement of ventricular volumes, muscle mass and function...

  13. Magnetic resonance imaging in obstetric diagnosis.

    Science.gov (United States)

    Weinreb, J C; Lowe, T W; Santos-Ramos, R; Cunningham, F G; Parkey, R

    1985-01-01

    Five patients with abnormal pregnancies were examined with ultrasound (US) and magnetic resonance imaging (MR). Three had a malformed fetus, 1 had a molar pregnancy, and 1 had an ovarian mass. Both maternal and fetal structures were clearly shown, although fetal motion may have resulted in image degradation in some cases. The authors suggest that MR may be useful in obstetric diagnosis.

  14. Magnetic resonance imaging of semicircular canals.

    Science.gov (United States)

    Sbarbati, A; Leclercq, F; Zancanaro, C; Antonakis, K

    1992-01-01

    The present paper reports the results of the first investigation of the semicircular canals in a living, small animal by means of high spatial resolution magnetic resonance imaging. This procedure is noninvasive and allows identification of the endolymphatic and perilymphatic spaces yielding a morphology quite consistent with direct anatomical examination. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 PMID:1506290

  15. Magnetic resonance imaging - first human images in Australia

    International Nuclear Information System (INIS)

    Baddeley, H.; Doddrell, D.M.; Brooks, W.M.; Field, J.; Irving, M.; Williams, J.E.

    1986-01-01

    The use of magnetic resonance imaging, in the demonstration of internal human anatomy and in the diagnosis of disease, has the major advantages that the technique is non-invasive, does not require the use of ionizing radiation and that it can demonstrate neurological and cardiovascular lesions that cannot be diagnosed easily by other imaging methods. The first magnetic resonance images of humans were obtained in Australia in October 1985 on the research instrument of the Queensland Medical Magnetic Resonance Research Centre, which is based at the Mater Hospital in Brisbane

  16. Value and limits of knee arthrography

    International Nuclear Information System (INIS)

    Fischedick, O.

    1981-01-01

    In the view of modern knowledges of biomechanic of the knee and the introduce of arthroscopy, the possibilities of arthrography will be discussed. The value of arthrography is not reduced, especially for the cruciate ligaments. Arthroscopy should follow arthrography in uncertain cases. (orig.) [de

  17. Basic principles of nuclear magnetic resonance imaging

    International Nuclear Information System (INIS)

    Valk, J.; MacLean, C.; Algra, P.R.

    1985-01-01

    The intent of this book is to help clinicians understand the basic physical principles of magnetic resonance (MR) imaging. The book consists of the following: a discussion of elementary considerations; pulse sequencing; localization of MR signals in space; MR equipment; MR contrast agents; clinical applications; MR spectroscopy; and biological effects of MR imaging; a set of appendixes; and a bibliography. Illustrations and images are included

  18. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... you, notify the radiologist or technologist. It is important that you remain perfectly still while the images are being obtained, which is typically only a few seconds to a few minutes at a time. You will know when images are being recorded ...

  19. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... technologist through the two-way intercom. It is important that your child remain perfectly still while the images are being obtained, which is typically only a few seconds to a few minutes at a time. Your child will know when images are being ...

  20. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... examination poses almost no risk to the average patient when appropriate safety guidelines are followed. If sedation is used, there ... have a personal story about radiology? Share your patient story here Images ... Disease Head Injury Brain Tumors Images related ...

  1. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos ... the body and determine the presence of certain diseases. The images can then be examined on a ...

  2. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... exposure to ionizing radiation. MR imaging of the soft-tissue structures of the body—such as the heart, liver and many other organs—is more likely in some instances to identify and accurately characterize diseases than other imaging methods. This detail makes MRI an invaluable tool in ...

  3. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... of which shows a thin slice of the body. The images can then be studied from different angles by ... information please consult the ACR Manual on Contrast Media and its references. top of page What are the limitations of MRI of the Head? High-quality images are assured only if you are able to ...

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... can also provide functional information (fMRI) in selected cases. MR images of the brain and other cranial structures are clearer and more detailed than with other imaging methods. This detail makes MRI an invaluable tool in early diagnosis and evaluation of many conditions, ...

  5. Magnetic resonance imaging of infectious myositis

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Ji Young; Kim, Jee Young; Kim, Sang Heum; Jung, Youn Ju; Cha, Eun Suk; Park, Joung Mi; Park, Young Ha [The Catholic Univ., College of Medicine, Suwon (Korea, Republic of)

    1998-09-01

    To describe the findings of magnetic resonance imaging in infectious myositis and to determine their value for differentiation between ruberculous and bacterial myositis. Magnetic resonance images of ten proven cases of infectious myositis (five tuberculous and five bacterial) were retrospectively reviewed in the light of clinical and laboratory findings. On the basis of magnetic resonance images, signal intensity of the mass, the presence or absence of an abscess, signal intensity of the peripheral wall, patterns of contrast enhancement, and associated findings were evaluated. Compared with those of bacterial myositis, the symptoms of tuberculous myositis lasted longer but there were no difinite local inflammatory signs. In three of five cases of bacterial myositis there were specific medical records;trauma in two cases and systemic lupus erythematosus in one. All tuberculous myositis cases involved a single muscle, but bacterial myositis affected multipe muscles in three cases(60%). All but one case showed a mass in the involved muscles. In one bacterial case, there was diffuse swelling in the involved muscle. On T1-weighted images, eight infectious cases showed low signal intensity;two, of the bactrerial type, showed subtle increased signal intensity. all cases demonstrated high signal intensity on t2-weighted images. The signal intensity of peripheral wall was slightly increased on T1-weighted images, but low on T2-weighted. In four cases there was associated cellulitis, and in one case each, adjacent joint effusion and deep vein thrombosis were seen. After gadolinium infusion, peripheral rim enhancement was noted in nine cases and heterogeneous enhancement in one. After magnetic resonance imaging of infectious myositis, the characteristic finding was an abscessed lesion, with the peripheral wall showing high signal intensity on T1-weighted images and low signal intensity on T2 weighted. Although we found it difficult to differentiate bacterial from tuberculous

  6. Magnetic resonance imaging of infectious myositis

    International Nuclear Information System (INIS)

    Yun, Ji Young; Kim, Jee Young; Kim, Sang Heum; Jung, Youn Ju; Cha, Eun Suk; Park, Joung Mi; Park, Young Ha

    1998-01-01

    To describe the findings of magnetic resonance imaging in infectious myositis and to determine their value for differentiation between ruberculous and bacterial myositis. Magnetic resonance images of ten proven cases of infectious myositis (five tuberculous and five bacterial) were retrospectively reviewed in the light of clinical and laboratory findings. On the basis of magnetic resonance images, signal intensity of the mass, the presence or absence of an abscess, signal intensity of the peripheral wall, patterns of contrast enhancement, and associated findings were evaluated. Compared with those of bacterial myositis, the symptoms of tuberculous myositis lasted longer but there were no difinite local inflammatory signs. In three of five cases of bacterial myositis there were specific medical records;trauma in two cases and systemic lupus erythematosus in one. All tuberculous myositis cases involved a single muscle, but bacterial myositis affected multipe muscles in three cases(60%). All but one case showed a mass in the involved muscles. In one bacterial case, there was diffuse swelling in the involved muscle. On T1-weighted images, eight infectious cases showed low signal intensity;two, of the bactrerial type, showed subtle increased signal intensity. all cases demonstrated high signal intensity on t2-weighted images. The signal intensity of peripheral wall was slightly increased on T1-weighted images, but low on T2-weighted. In four cases there was associated cellulitis, and in one case each, adjacent joint effusion and deep vein thrombosis were seen. After gadolinium infusion, peripheral rim enhancement was noted in nine cases and heterogeneous enhancement in one. After magnetic resonance imaging of infectious myositis, the characteristic finding was an abscessed lesion, with the peripheral wall showing high signal intensity on T1-weighted images and low signal intensity on T2 weighted. Although we found it difficult to differentiate bacterial from tuberculous

  7. Contemporary imaging: Magnetic resonance imaging, computed tomography, and interventional radiology

    International Nuclear Information System (INIS)

    Goldberg, H.I.; Higgins, C.; Ring, E.J.

    1985-01-01

    In addition to discussing the most recent advances in magnetic resonance imaging (MRI), computerized tomography (CT), and the vast array of interventional procedures, this book explores the appropriate clinical applications of each of these important modalities

  8. Structural magnetic resonance imaging in epilepsy

    International Nuclear Information System (INIS)

    Deblaere, Karel; Achten, Eric

    2008-01-01

    Because of its sensitivity and high tissue contrast, magnetic resonance imaging (MRI) is the technique of choice for structural imaging in epilepsy. In this review the effect of using optimised scanning protocols and the use of high field MR systems on detection sensitivity is discussed. Also, the clinical relevance of adequate imaging in patients with focal epilepsy is highlighted. The most frequently encountered MRI findings in epilepsy are reported and their imaging characteristics depicted. Imaging focus will be on the diagnosis of hippocampal sclerosis and malformations of cortical development, two major causes of medically intractable focal epilepsy. (orig.)

  9. Structural magnetic resonance imaging in epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Deblaere, Karel [Ghent University Hospital, Department of Neuroradiology, Ghent (Belgium); Ghent University Hospital, MR Department - 1K12, Ghent (Belgium); Achten, Eric [Ghent University Hospital, Department of Neuroradiology, Ghent (Belgium)

    2008-01-15

    Because of its sensitivity and high tissue contrast, magnetic resonance imaging (MRI) is the technique of choice for structural imaging in epilepsy. In this review the effect of using optimised scanning protocols and the use of high field MR systems on detection sensitivity is discussed. Also, the clinical relevance of adequate imaging in patients with focal epilepsy is highlighted. The most frequently encountered MRI findings in epilepsy are reported and their imaging characteristics depicted. Imaging focus will be on the diagnosis of hippocampal sclerosis and malformations of cortical development, two major causes of medically intractable focal epilepsy. (orig.)

  10. The posterior transtriceps approach for elbow arthrography: a forgotten technique?

    International Nuclear Information System (INIS)

    Lohman, M.; Borrero, C.; Casagranda, B.; Rafiee, B.; Towers, J.

    2009-01-01

    To evaluate the technical feasibility of performing elbow MR arthrography via a posterior approach through the triceps. The images of 19 patients with elbow MR arthrography via a posterior transtriceps approach were retrospectively studied. The injections were performed by four musculoskeletal radiologists, using fluoroscopic guidance and a 22- or 25-gauge needle. The fluoroscopic and subsequent MR images were reviewed by two musculoskeletal radiologists and evaluated for adequacy of joint capsular distention, degree and location of contrast leakage, and presence of gas bubbles. The injection was diagnostic in all 19 patients, with a sufficient amount of contrast agent seen in the elbow joint. No significant contrast leakage occurred in 12 patients who received injections of 8 cc or less of contrast agent, but moderate contrast leakage occurred in 6/7 patients who received injections of greater than 8 cc. Contrast leakage generally occurred within the triceps myotendinous junction. No gas bubbles were identified in the injected joints. Patients often present for MR arthrography of the elbow with medial or lateral elbow pain. Contrast leakage during a radiocapitellar approach may complicate evaluation of the lateral collateral ligament or the common extensor tendon origin. Transtriceps MR arthrography offers an alternative to the more commonly used radiocapitellar approach. With injected volumes not exceeding 8 cc, the risk of significant contrast leakage is small. An advantage of the transtriceps injection is that contrast leakage through the posterior needle tract does not interfere with evaluation of the lateral structures. (orig.)

  11. Nuclear magnetic resonance spectroscopy and imaging

    International Nuclear Information System (INIS)

    Jiang Weiping; Wang Qi; Zhou Xin

    2013-01-01

    This paper briefly introduces the basic principle of nuclear magnetic resonance (NMR). Protein's structures and functions and dynamics studied by liquid NMR are elaborated; methods for enhancing the resolution of solid state NMR and its applications are discussed; the principle of magnetic resonance imaging (MRI) is interpreted, and applications in different aspects are reviewed. Finally, the progress of NMR is commented. (authors)

  12. Clinical magnetic resonance: imaging and spectroscopy

    International Nuclear Information System (INIS)

    Andrew, E.R.; Bydder, Graeme; Griffiths, John; Iles, Richard; Styles, Peter

    1990-01-01

    This book begins with a readable, comprehensive but non-mathematical introduction to the basic underlying principles of magnetic resonance. Further chapters include information on the theory and principles of MRI and MRS, the interpretation of MR images, the clinical applications and scope of MRI and MRS, practical aspects of spectroscopy and magnetic resonance, and also the practical problems associated with the siting, safety and operation of large MRI and MRS equipment. (author)

  13. Magnetic resonance imaging of breast implants.

    Science.gov (United States)

    Shah, Mala; Tanna, Neil; Margolies, Laurie

    2014-12-01

    Silicone breast implants have significantly evolved since their introduction half a century ago, yet implant rupture remains a common and expected complication, especially in patients with earlier-generation implants. Magnetic resonance imaging is the primary modality for assessing the integrity of silicone implants and has excellent sensitivity and specificity, and the Food and Drug Administration currently recommends periodic magnetic resonance imaging screening for silent silicone breast implant rupture. Familiarity with the types of silicone implants and potential complications is essential for the radiologist. Signs of intracapsular rupture include the noose, droplet, subcapsular line, and linguine signs. Signs of extracapsular rupture include herniation of silicone with a capsular defect and extruded silicone material. Specific sequences including water and silicone suppression are essential for distinguishing rupture from other pathologies and artifacts. Magnetic resonance imaging provides valuable information about the integrity of silicone implants and associated complications.

  14. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI can detect stroke at a very early stage by mapping the motion of water molecules in ... is because traction devices and many types of life support equipment may distort the MR images and ...

  15. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site ...

  16. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... images removable dental work pens, pocket knives and eyeglasses body piercings In most cases, an MRI exam ... and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media ...

  17. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... images removable dental work pens, pocket knives and eyeglasses body piercings In most cases, an MRI exam ... and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media ...

  18. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... scanner. top of page How does the procedure work? Unlike conventional x-ray examinations and computed tomography ( ... medical imaging or radiation oncology provider in your community, you can search the ACR-accredited facilities database . ...

  19. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... scanner. top of page How does the procedure work? Unlike conventional x-ray examinations and computed tomography ( ... medical imaging or radiation oncology provider in your community, you can search the ACR-accredited facilities database . ...

  20. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... the exam. MRI scanners are air-conditioned and well-lit. Music may be played through the headphones ... full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy ...

  1. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... the exam. MRI scanners are air-conditioned and well-lit. Music may be played through the headphones ... full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy ...

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings ... and send a signed report to your primary care or referring physician, who will share the results ...

  3. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings ... and send a signed report to your primary care or referring physician, who will share the results ...

  4. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... a risk, depending on their nature and the strength of the MRI magnet. Many implanted devices will ... full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy ...

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... a risk, depending on their nature and the strength of the MRI magnet. Many implanted devices will ... full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy ...

  6. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... examination poses almost no risk to the average patient when appropriate safety guidelines are followed. If sedation is used, there ... patient story here Images × ... and Radiation Safety Videos related ...

  7. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... tissue from which they come. The MR scanner captures this energy and creates a picture of the ... imaging based on the electrical activity of the heart, such as electrocardiography (EKG). MRI generally is not ...

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... it may cause some medical devices to malfunction. Most orthopedic implants pose no risk, but you should ... a digital cloud server. Currently, MRI is the most sensitive imaging test of the head (particularly the ...

  9. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... six weeks) before being safe for MRI examinations. Examples include but are not limited to: artificial heart ... electrocardiography (ECG). MRI typically costs more and may take more time to perform than other imaging modalities. ...

  10. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... to a CD or uploaded to a digital cloud server. top of page What are some common ... over time. top of page What are the benefits vs. risks? Benefits MRI is a noninvasive imaging ...

  11. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... or patients with claustrophobia. Other MRI machines are open on the sides (open MRI). Open units are especially helpful for examining larger patients or those with claustrophobia. Newer open MRI units provide very high quality images for ...

  12. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... or patients with claustrophobia. Other MRI machines are open on the sides (open MRI). Open units are especially helpful for examining larger patients or those with claustrophobia. Newer open MRI units provide very high quality images for ...

  13. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings In most cases, an MRI exam is safe for patients with metal implants, except for a few types. ...

  14. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings In most cases, an MRI exam is safe for patients with metal implants, except for a few types. ...

  15. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... and may add approximately 15 minutes to the total exam time. top of page What will my ... are the limitations of Children’s (Pediatric) MRI? High-quality images are assured only if your child is ...

  16. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... and may add approximately 15 minutes to the total exam time. top of page What will I ... the limitations of MRI of the Head? High-quality images are assured only if you are able ...

  17. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... distort images of the facial area or brain, so you should let the radiologist know about them. ... MRI units, called short-bore systems , are designed so that the magnet does not completely surround you. ...

  18. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... distort images of the facial area or brain, so the radiologist should be aware of them. Parents ... MRI units, called short-bore systems , are designed so that the magnet does not completely surround you. ...

  19. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... wide range of conditions in children due to injury, illness or congenital abnormalities. When imaging of a child’s brain and spinal cord is needed, MRI is useful because of ...

  20. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... to a CD or uploaded to a digital cloud server. Currently, MRI is the most sensitive imaging ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  1. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... experience some bruising. There is also a very small chance of skin irritation at the site of ... a result, must be kept away from the area to be imaged. Furthermore, the examination takes longer ...

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... experience some bruising. There is also a very small chance of irritation of your skin at the ... a result, must be kept away from the area to be imaged. Furthermore, the examination takes longer ...

  3. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings In most cases, an MRI exam is safe for patients with metal implants, except for a ...

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings In most cases, an MRI exam is safe for patients with metal implants, except for a ...

  5. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... to cancer treatment MRI is often the best choice for imaging the joints and bones, where it ... regular daily routine and have him/her take food and medications as usual. Some MRI examinations may ...

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... processes the imaging information is located in a separate room from the scanner. top of page How does the procedure work? Unlike conventional x-ray examinations and computed tomography ( ...

  7. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... processes the imaging information is located in a separate room from the scanner. top of page How does the procedure work? Unlike conventional x-ray examinations and computed tomography ( ...

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... images can then be examined on a computer monitor, transmitted electronically, printed or copied to a CD ... excessive sedation. However, the technologist or nurse will monitor your vital signs to minimize this risk. Although ...

  9. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... an MRI scan, but this is rare. Tooth fillings and braces usually are not affected by the magnetic field, but they may distort images of the facial area or brain, so you should let the ...

  10. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... lodged in the eyes are particularly important. Tooth fillings and braces usually are not affected by the magnetic field, but they may distort images of the facial area or brain, so the radiologist should be ...

  11. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings ... tomography (CT) scans, MRI does not utilize ionizing radiation. Instead, radiofrequency pulses re-align hydrogen atoms that ...

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings ... tomography (CT) scans, MRI does not utilize ionizing radiation. Instead, radiofrequency pulses re-align hydrogen atoms that ...

  13. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... eating and drinking before your exam vary between facilities. Unless you are told otherwise, take your regular ... with the specific exam and with the imaging facility. Unless you are told otherwise, you may follow ...

  14. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... a CD or uploaded to a digital cloud server. Currently, MRI is the most sensitive imaging test ... understanding of the possible charges you will incur. Web page review process: This Web page is reviewed ...

  15. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... room. In addition to affecting the MRI images, these objects can become projectiles within the MRI scanner ... may cause you and/or others nearby harm. These items include: jewelry, watches, credit cards and hearing ...

  16. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... range of conditions in children due to injury, illness or congenital abnormalities. When imaging of a child’s ... or other reactions. If your child experiences allergic symptoms, a radiologist or other physician will be available ...

  17. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... examinations may require your child to receive an injection of contrast material into the bloodstream. The radiologist , ... images will be taken during or following the injection. When the examination is complete, you and your ...

  18. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... be asked to maintain his/her position without movement as much as possible. In some cases, intravenous ... makes it difficult to obtain clear images. Patient movement can have the same effect. A very irregular ...

  19. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... the exam room. These items include: jewelry, watches, credit cards and hearing aids, all of which can ... top of page What are the benefits vs. risks? Benefits MRI is a noninvasive imaging technique that ...

  20. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... others nearby harm. These items include: jewelry, watches, credit cards and hearing aids, all of which can ... top of page What are the benefits vs. risks? Benefits MRI is a noninvasive imaging technique that ...

  1. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... This website does not provide cost information. The costs for specific medical imaging tests, treatments and procedures may vary by geographic region. Discuss the fees associated with your prescribed procedure with your doctor, ...

  2. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... This website does not provide cost information. The costs for specific medical imaging tests, treatments and procedures may vary by geographic region. Discuss the fees associated with your prescribed procedure with your doctor, ...

  3. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... to produce detailed pictures of organs, soft tissues, bone and virtually all other internal body structures. MRI ... discovery of abnormalities that might be obscured by bone with other imaging methods. The contrast material used ...

  4. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... To locate a medical imaging or radiation oncology provider in your community, you can search the ACR- ... the medical facility staff and/or your insurance provider to get a better understanding of the possible ...

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... contrast for an MRI. If you have a history of kidney disease or liver transplant, it will ... claustrophobia. Newer open MRI units provide very high quality images for many types of exams. Older open ...

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... radiation oncology provider in your community, you can search the ACR-accredited facilities database . This website does not provide cost information. The costs for specific medical imaging tests, treatments ...

  7. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... radiation oncology provider in your community, you can search the ACR-accredited facilities database . This website does not provide cost information. The costs for specific medical imaging tests, treatments ...

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... top of page Additional Information and Resources RTAnswers.org : Radiation Therapy for Brain Tumors Radiation Therapy for ... Imaging (MRI) - Head Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ...

  9. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... range of conditions in children due to injury, illness or congenital abnormalities. When imaging of a child’s ... material may be performed. The intravenous needle may cause your child some discomfort when it is inserted ...

  10. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... with metal implants, except for a few types. People with the following implants cannot be scanned and ... it difficult to lie still during imaging. A person who is very large may not fit into ...

  11. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... with metal implants, except for a few types. People with the following implants cannot be scanned and ... it difficult to lie still during imaging. A person who is very large may not fit into ...

  12. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... and pelvic region, MRI is used to: diagnose causes of pain evaluate for injury after trauma diagnose and monitor infectious or inflammatory disorders monitor response to cancer treatment MRI is often the best choice for imaging ...

  13. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Magnetic ...

  14. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... practice. top of page What are some common uses of the procedure? MR imaging of the head ... gadolinium contrast, it may still be possible to use it after appropriate pre-medication. Patient consent will ...

  15. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... is done because a potential abnormality needs further evaluation with additional views or a special imaging technique. ... MRI an invaluable tool in early diagnosis and evaluation of many conditions, including tumors. MRI enables the ...

  16. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... or headphones during the exam. MRI scanners are air-conditioned and well-lit. Music may be played ... the limitations of MRI of the Head? High-quality images are assured only if you are able ...

  17. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... type your comment or suggestion into the following text box: Comment: E-mail: Area code: Phone no: Thank ... View full size with caption Pediatric Content Some imaging tests ...

  18. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... type your comment or suggestion into the following text box: Comment: E-mail: Area code: Phone no: Thank ... View full size with caption Pediatric Content Some imaging tests ...

  19. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... to: artificial heart valves implanted drug infusion ports artificial limbs or metallic joint prostheses implanted nerve stimulators metal ... will analyze the images and send a signed report to your primary care or referring physician, who ...

  20. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... wide range of conditions in children due to injury, illness or congenital abnormalities. When imaging of a child’s brain and spinal cord is needed, MRI is useful because of its ...

  1. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... confused or in severe pain, he/she may find it difficult to lie still during imaging. A ... 25, 2016 Send us your feedback Did you find the information you were looking for? Yes No ...

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... determine the presence of certain diseases. The images can then be examined on a computer monitor, transmitted ... of abrupt onset or long-standing symptoms. It can help diagnose conditions such as: brain tumors stroke ...

  3. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... for scanning patients since the 1980s with no reports of any ill effects on pregnant women or ... will analyze the images and send a signed report to your primary care or referring physician, who ...

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... used in tattoos may contain iron and could heat up during an MRI scan, but this is ... imaging based on the electrical activity of the heart, such as electrocardiography (EKG). MRI generally is not ...

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... used in tattoos may contain iron and could heat up during an MRI scan, but this is ... called MR angiography (MRA) provides detailed images of blood vessels in the brain—often without the need ...

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... you should let the radiologist know about them. Parents or family members who accompany patients into the ... part of the body being imaged, send and receive radio waves, producing signals that are detected by ...

  7. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... On very rare occasions, a few patients experience side effects from the contrast material, including nausea, headache and ... structures of the brain and can also provide functional information (fMRI) in selected cases. MR images of ...

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... practice. top of page What are some common uses of the procedure? MR imaging of the head ... for immediate assistance. Manufacturers of intravenous contrast indicate mothers should not breastfeed their babies for 24-48 ...

  9. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... the area of your body being imaged to feel slightly warm, but if it bothers you, notify ... are being recorded because you will hear and feel loud tapping or thumping sounds when the coils ...

  10. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... area of your child’s body being imaged to feel slightly warm, but if your child is bothered ... being recorded because he/she will hear and feel loud tapping or thumping sounds when the coils ...

  11. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... scanner. top of page How does the procedure work? Unlike conventional x-ray examinations and computed tomography ( ... is because traction devices and many types of life support equipment may distort the MR images and ...

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... scanner. top of page How does the procedure work? Unlike conventional x-ray examinations and computed tomography ( ... is because traction devices and many types of life support equipment may distort the MR images and ...

  13. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index ...

  14. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index ...

  15. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... images and send a signed report to your primary care or referring physician, who will share the ... Society of Urogenital Radiology note that the available data suggest that it is safe to continue breastfeeding ...

  16. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... a computer to produce detailed pictures of the brain and other cranial structures that are clearer and ... sensitive imaging test of the head (particularly the brain) in routine clinical practice. top of page What ...

  17. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... treatment for a variety of conditions within the brain, chest, abdomen, pelvis and extremities. Tell your doctor ... or congenital abnormalities. When imaging of a child’s brain and spinal cord is needed, MRI is useful ...

  18. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... Examples include but are not limited to: artificial heart valves implanted drug infusion ports artificial limbs or ... imaging based on the electrical activity of the heart, such as electrocardiography (EKG). MRI generally is not ...

  19. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... practice. top of page What are some common uses of the procedure? MR imaging of the head ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  20. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI) procedure View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media MR Angiography (MRA) Magnetic ...

  1. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... after the exam. A few patients experience side effects from the contrast material, including nausea and local ... clear images. Patient movement can have the same effect. A very irregular heartbeat may affect the quality ...

  2. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... in children due to injury, illness or congenital abnormalities. When imaging of a child’s brain and spinal ... to: detect a variety of brain conditions and abnormalities like cysts, tumors, bleeding, swelling, or problems with ...

  3. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... structures of the brain and can also provide functional information (fMRI) in selected cases. MR images of the brain and other cranial structures are clearer and more detailed than with other ...

  4. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... no: Thank you! Do you have a personal story about radiology? Share your patient story here Images × ... Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2018 Radiological Society of North America, Inc. ( ...

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... no: Thank you! Do you have a personal story about radiology? Share your patient story here Images × ... Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2018 Radiological Society of North America, Inc. ( ...

  6. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits MRI is a noninvasive imaging technique that ... used for conventional x-rays and CT scanning. Risks The MRI examination poses almost no risk to ...

  7. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits MRI is a noninvasive imaging technique that ... than 30 minutes from the onset of symptoms. Risks The MRI examination poses almost no risk to ...

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... produce detailed pictures of the brain and other cranial structures that are clearer and more detailed than ... cases. MR images of the brain and other cranial structures are clearer and more detailed than with ...

  9. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Open units are especially helpful for examining larger patients or those with claustrophobia. Newer open MRI units provide very high quality images for many types of exams; however, older ...

  10. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... scanner. top of page How does the procedure work? Unlike conventional x-ray examinations and computed tomography ( ... the same effect. A very irregular heartbeat may affect the quality of images obtained using techniques that ...

  11. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... scanner. top of page How does the procedure work? Unlike conventional x-ray examinations and computed tomography ( ... the same effect. A very irregular heartbeat may affect the quality of images obtained using techniques that ...

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... tissue and fluid, known as edema . MRI typically costs more and may take more time to perform ... accredited facilities database . This website does not provide cost information. The costs for specific medical imaging tests, ...

  13. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... the heart, such as electrocardiography (ECG). MRI typically costs more and may take more time to perform ... accredited facilities database . This website does not provide cost information. The costs for specific medical imaging tests, ...

  14. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... have a history of kidney disease or liver transplant, it will be necessary to perform a blood ... discovery of abnormalities that might be obscured by bone with other imaging methods. The contrast material used ...

  15. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... other internal body structures. MRI does not use ionizing radiation (x-rays). Detailed MR images allow physicians ... computed tomography (CT) scans, MRI does not utilize ionizing radiation. Instead, radiofrequency pulses re-align hydrogen atoms ...

  16. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... Detailed MR images allow physicians to evaluate various parts of the body and determine the presence of ... Patients who might have metal objects in certain parts of their bodies may also require an x- ...

  17. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... MRI. For more information, consult your radiologist. The computer workstation that processes the imaging information is located ... not come in contact with the patient. A computer then processes the signals and generates a series ...

  18. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI. For more information, consult your radiologist. The computer workstation that processes the imaging information is located ... not come in contact with the patient. A computer then processes the signals and generates a series ...

  19. Hip Imaging in Athletes: Sports Imaging Series.

    Science.gov (United States)

    Agten, Christoph A; Sutter, Reto; Buck, Florian M; Pfirrmann, Christian W A

    2016-08-01

    Hip or groin pain in athletes is common and clinical presentation is often nonspecific. Imaging is a very important diagnostic step in the work-up of athletes with hip pain. This review article provides an overview on hip biomechanics and discusses strategies for hip imaging modalities such as radiography, ultrasonography, computed tomography, and magnetic resonance (MR) imaging (MR arthrography and traction MR arthrography). The authors explain current concepts of femoroacetabular impingement and the problem of high prevalence of cam- and pincer-type morphology in asymptomatic persons. With the main focus on MR imaging, the authors present abnormalities of the hip joint and the surrounding soft tissues that can occur in athletes: intraarticular and extraarticular hip impingement syndromes, labral and cartilage disease, microinstability of the hip, myotendinous injuries, and athletic pubalgia. (©) RSNA, 2016.

  20. Magnetic resonance imaging at Rikshospitalet

    International Nuclear Information System (INIS)

    Smith, H.J.

    1990-01-01

    During the first 18 months of operations of the nuclear magnetic resonance (NMR) unit at Rikshospitalet, 1453 NMR examinations have been performed on 1431 patients. 64% of the time has been devoted to examinations of the central nervous system and spine in children and adults, 9% of the time has been used on non-neuroradiology pediatric patients, while the rest of the time has been spent equally on ear, nose and throat, thoracic (including cardiac) and abdominal examinations in adult patients. The indications for doing NMR at Rikshospitalet are listed and discussed, and it is concluded that NMR has proved to be useful at several conditions in most organ systems. 15 refs