WorldWideScience

Sample records for resonance imaging arthrography

  1. Evaluation of TFC tears with magnetic resonance imaging; Comparison with arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Kushida, Manabu; Imamura, Koutaro; Sumi, Mitsuhiro; Uetani, Masataka (Nagasaki Univ. (Japan). School of Medicine); Nagatani, Yoshifumi

    1993-09-01

    This study evaluated the accuracy of magnetic resonance imaging (MRI) in the detection of tears of the trianglar fibrocartilage (TFC). Eighteen patients with chronic pain in the ulnar side of their wrist were examined by MRI and arthrography. Compared with arthrography, MRI was effective in the evaluation of TFC tears with a sensitivity of 92%, a specificity of 67%, and an accuracy of 83%. (author).

  2. Arthrography

    Medline Plus

    Full Text Available ... joint. Arthrography may use computed tomography (CT) scanning, magnetic resonance imaging (MRI) or fluoroscopy – a form of real- ... methods of direct arthrography examinations may also use magnetic resonance imaging (MRI) or computed tomography (CT) following contrast ...

  3. Evaluation of the triangular fibrocartilage complex tears by arthrography and MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, Makoto; Shibata, Yasushi [Hokkaido Kin-i-kyou Central Hospital, Sapporo (Japan); Takahata, Naoji

    1995-08-01

    Arthroscopic or open surgical findings in 21 wrists with chronic ulnar painful lesion were compared both with arthrography and magnetic resonance (MR) imaging results to evaluate the accuracy of the two diagnostic procedures in the detection of triangular fibrocartilage complex (TFCC) lesions. Arthrography investigations were performed for the 20 wrists but one that had allergy for iodine and MR imagings were performed for the recent 12 wrists. Arthrography and magnetic resonance (MR) imaging were almost equally useful for the detection of the TFCC injury and their injury sites. (author).

  4. Arthrography

    Medline Plus

    Full Text Available ... injected into the joint. Arthrography may use computed tomography (CT) scanning, magnetic resonance imaging (MRI) or fluoroscopy – ... also use magnetic resonance imaging (MRI) or computed tomography (CT) following contrast material injection into the joint. ...

  5. Arthrography

    Medline Plus

    Full Text Available ... injected into the joint. Arthrography may use computed tomography (CT) scanning, magnetic resonance imaging (MRI) or fluoroscopy – a ... also use magnetic resonance imaging (MRI) or computed tomography (CT) following contrast material injection into the joint. An ...

  6. Preoperative conventional magnetic resonance images versus magnetic resonance arthrography of subacromial impingement syndrome

    International Nuclear Information System (INIS)

    Ahn, Sang Hyuk; Park, Jung Hwan; Moon, Tae Yong; Lee, In Sook; Lee, Seung Jun

    2012-01-01

    To evaluate the usefulness of conventional magnetic resonance images (MRI) for arthroscopic surgery in subacromial impingement syndrome of the shoulder, as an alternative to MR arthrography with additional T2 fat saturation images (MRA). The preoperative MRI of 77 patients (45 females, 32 males) (52 right, 25 left) and MRA of 34 patients (14 females, 20 males) (24 right, 10 left) with subsequent arthroscopic confirmation of subacromial impingement syndrome were reviewed retrospectively. The lesions requiring arthroscopic surgery were 95 subacromial spurs, 101 subacromial bursitis, and 51 full-thickness and 44 partial thickness tears of the supraspinatus among 111 cases for both studies. A two by two table was constructed in order to calculate the sensitivity and specificity of both studies against arthroscopic outcomes. Also we analyzed the false positive and false negative cases of the full-thickness tears individually. The detection rates of subacromial spur and bursitis and full and partial thickness tears of the supraspinatus were 91%, 94%, 77%, and 65% in MRI and 93%, 100%, 83%, and 77% in MRA respectively. Their specificities were 33%, 33%, 90%, and 76% in MRI and 50%, 75%, 100%, and 71% in MRA respectively. Eleven false negative cases in regards to MRI resulted in Ellman's grade 3 partial thickness tear (72.7%), mild bursitis (63.6%), greater tuberosity erosion (45.5%), and negative fluid signal of the glenohumeral joint (81.8%). Three false positive cases on the MRI were induced from errors with lower window depth and width on the imagings. Two false negative cases on MRA were induced from the adhesion between Ellman's grade 3 rim rent tear and the glenohumeral joint cavity. Conventional MR images could be used to decide the arthroscopic surgery in subacromial impingement syndrome, as an alternative to MR arthrography with additional T2 fat saturation images

  7. Preoperative conventional magnetic resonance images versus magnetic resonance arthrography of subacromial impingement syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Sang Hyuk; Park, Jung Hwan; Moon, Tae Yong [Pusan National Univ. Yangsan Hospital, Yangsan (Korea, Republic of); Lee, In Sook; Lee, Seung Jun [Pusan National Univ. Hospital, Busan (Korea, Republic of)

    2012-09-15

    To evaluate the usefulness of conventional magnetic resonance images (MRI) for arthroscopic surgery in subacromial impingement syndrome of the shoulder, as an alternative to MR arthrography with additional T2 fat saturation images (MRA). The preoperative MRI of 77 patients (45 females, 32 males) (52 right, 25 left) and MRA of 34 patients (14 females, 20 males) (24 right, 10 left) with subsequent arthroscopic confirmation of subacromial impingement syndrome were reviewed retrospectively. The lesions requiring arthroscopic surgery were 95 subacromial spurs, 101 subacromial bursitis, and 51 full-thickness and 44 partial thickness tears of the supraspinatus among 111 cases for both studies. A two by two table was constructed in order to calculate the sensitivity and specificity of both studies against arthroscopic outcomes. Also we analyzed the false positive and false negative cases of the full-thickness tears individually. The detection rates of subacromial spur and bursitis and full and partial thickness tears of the supraspinatus were 91%, 94%, 77%, and 65% in MRI and 93%, 100%, 83%, and 77% in MRA respectively. Their specificities were 33%, 33%, 90%, and 76% in MRI and 50%, 75%, 100%, and 71% in MRA respectively. Eleven false negative cases in regards to MRI resulted in Ellman's grade 3 partial thickness tear (72.7%), mild bursitis (63.6%), greater tuberosity erosion (45.5%), and negative fluid signal of the glenohumeral joint (81.8%). Three false positive cases on the MRI were induced from errors with lower window depth and width on the imagings. Two false negative cases on MRA were induced from the adhesion between Ellman's grade 3 rim rent tear and the glenohumeral joint cavity. Conventional MR images could be used to decide the arthroscopic surgery in subacromial impingement syndrome, as an alternative to MR arthrography with additional T2 fat saturation images.

  8. Discrepancy between fluoroscopic arthrography and magnetic resonance arthrography in patients with arthroscopically confirmed supraspinatus tendon tears: The additional benefit of cine fluoroscopic arthrography images

    International Nuclear Information System (INIS)

    Hahn, Seok; Lee, Young Han; Suh, Jin Suck

    2016-01-01

    To determine the additional diagnostic benefits of fluoroscopic arthrography (FA) in patients with full-thickness supraspinatus tendon (SST) tears by comparing FA images with magnetic resonance arthrography (MRA) images. This study included FA and MRA images of 53 patients who were confirmed to have full-thickness SST tears by arthroscopy. In the FA analysis, the presence of contrast leakage into the subacromial-subdeltoid bursa was recorded. In the MRA analysis, contrast leakage, retraction of a torn tendon, width and length of the tear, and supraspinatus atrophy were evaluated. Patients were divided into the concordant group or the discordant group based on the presence of contrast leakage to compare the characteristics of SST tears. We used Fisher's exact test and two-sample t-test for the comparison. Of the 53 patients, 34 were included in the concordant group and 19 were included in the discordant group. In the concordant group, the grades of retraction were higher than those in the discordant group; the width and length of the tears were larger. Muscle atrophy was more severe in the concordant group. A full-thickness SST tear did not always exhibit contrast leakage on FA, particularly small SST tears or tears with low-grade retraction. FA can provide diagnostic information regarding the severity of full-thickness SST tears by itself

  9. Discrepancy between fluoroscopic arthrography and magnetic resonance arthrography in patients with arthroscopically confirmed supraspinatus tendon tears: The additional benefit of cine fluoroscopic arthrography images

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, Seok; Lee, Young Han; Suh, Jin Suck [Dept. Radiology, Research Institute of Radiological Science, Medical Convergence Research Institute, and Severance Biomedical Science Institute, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2016-12-15

    To determine the additional diagnostic benefits of fluoroscopic arthrography (FA) in patients with full-thickness supraspinatus tendon (SST) tears by comparing FA images with magnetic resonance arthrography (MRA) images. This study included FA and MRA images of 53 patients who were confirmed to have full-thickness SST tears by arthroscopy. In the FA analysis, the presence of contrast leakage into the subacromial-subdeltoid bursa was recorded. In the MRA analysis, contrast leakage, retraction of a torn tendon, width and length of the tear, and supraspinatus atrophy were evaluated. Patients were divided into the concordant group or the discordant group based on the presence of contrast leakage to compare the characteristics of SST tears. We used Fisher's exact test and two-sample t-test for the comparison. Of the 53 patients, 34 were included in the concordant group and 19 were included in the discordant group. In the concordant group, the grades of retraction were higher than those in the discordant group; the width and length of the tears were larger. Muscle atrophy was more severe in the concordant group. A full-thickness SST tear did not always exhibit contrast leakage on FA, particularly small SST tears or tears with low-grade retraction. FA can provide diagnostic information regarding the severity of full-thickness SST tears by itself.

  10. All-in-One Magnetic Resonance Arthrography of the Shoulder in a Vertically Open Magnetic Resonance Unit

    Energy Technology Data Exchange (ETDEWEB)

    Vandevenne, J.E.; Vanhoenacker, F.; Beaulieu, C.F.; Bergman, A.; Butts Pauly, K.; Dillingham, M.F.; Lang, P.K. (Dept. of Radiology, Univ. Hospital Antwerp, Edegem-Antwerp (Belgium))

    2008-10-15

    Background: Magnetic resonance (MR) arthrography frequently involves joint injection under imaging guidance followed by MR imaging in static positions. Purpose: To evaluate if MR arthrography of the shoulder joint can be performed in a comprehensive fashion combining the MR-guided injection procedure, static MR imaging, and dynamic motion MR imaging in a single test. Material and Methods: Twenty-three shoulder joints were injected with Gd-DTPA2- under MR guidance. Static MR imaging was performed and included a three-point Dixon method to achieve water-selective images. Dynamic motion MR imaging with and without applying pressure to the upper arm was used to evaluate glenohumeral joint instability. In 10 cases, surgical correlation was available. Results: The all-in-one MR arthrography technique was successful in all patients, and took an average time of 65 min. All but one glenohumeral injection procedure were performed with a single needle pass, and no complications were observed. Out of eight labrum tears seen with static MR imaging, seven were confirmed at surgery. In 10 cases, dynamic motion MR imaging correlated well with the surgeon's intraoperative evaluation for presence and direction of instability. Conclusion: MR arthrography of the shoulder joint using a vertically open magnet can be performed as a single comprehensive test, including the injection and the static and dynamic motion MR imaging. Good diagnostic accuracy for intraarticular lesions and glenohumeral instability was found in a small sample.

  11. Arthrography

    Medline Plus

    Full Text Available ... may be used to guide the procedure. Alternate methods of direct arthrography examinations may also use magnetic resonance imaging (MRI) or computed tomography (CT) following ...

  12. Prospective, double-blind comparison of shoulder MR imaging, US, arthrography, and arthroscopy

    International Nuclear Information System (INIS)

    Resendes, M.; Drace, J.E.; Pyka, W.

    1988-01-01

    To determine the efficacy of diagnostic imaging modalities in the evaluation of shoulder pain, magnetic resonance (MR) imaging, ultrasonography (US) and arthrography were prospectively compared in a double-blind experimental protocol. Thirty consecutive patients were studied by these modalities, which received separate, blinded interpretations. The images and interpretations were sealed in an envelope and blinded from the arthroscopist for initial arthroscopy, but second-look arthroscopy, and in some cases open surgery, was performed after the envelopes were unsealed. To avoid selection bias, negative MR and/or US examinations never affected confirmation by arthrography and/or arthroscopy, so negatives and positives were equivalently tested. To date, MR imaging and US are equally sensitive in the detection of rotator cuff tears, but the combination is more sensitive. Both MR imaging and US demonstrated tears not diagnosed by means of arthrography, and MR imaging distinguished hemorrhagic muscle tears from rotator cuff tears, which arthrography and arthroscopy did not. Both MR imaging and US showed characteristic appearances of biceps tendonitis, but neither demonstrated adhesive capsulitis. The authors conclude that all three imaging modalities have a role in shoulder diagnosis

  13. Arthrography

    Medline Plus

    Full Text Available ... guide the procedure. Alternate methods of direct arthrography examinations may also use magnetic resonance imaging (MRI) or ... the injection is typically monitored by fluoroscopy, the examination also commonly involves taking radiographs for documentation. These ...

  14. Arthrography

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Direct Arthrography Arthrography is a type of medical imaging ... are the limitations of Direct Arthrography? What is Direct Arthrography? Arthrography is medical imaging to evaluate conditions ...

  15. Arthrography

    Medline Plus

    Full Text Available ... Z Direct Arthrography Arthrography is a type of medical imaging used to help evaluate and diagnose joint conditions ... Direct Arthrography? What is Direct Arthrography? Arthrography is medical imaging to evaluate conditions of joints. It can either ...

  16. Optimization of T2-weighted imaging for shoulder magnetic resonance arthrography by synthetic magnetic resonance imaging.

    Science.gov (United States)

    Lee, Seung Hyun; Lee, Young Han; Hahn, Seok; Yang, Jaemoon; Song, Ho-Taek; Suh, Jin-Suck

    2017-01-01

    Background Synthetic magnetic resonance imaging (MRI) allows reformatting of various synthetic images by adjustment of scanning parameters such as repetition time (TR) and echo time (TE). Optimized MR images can be reformatted from T1, T2, and proton density (PD) values to achieve maximum tissue contrast between joint fluid and adjacent soft tissue. Purpose To demonstrate the method for optimization of TR and TE by synthetic MRI and to validate the optimized images by comparison with conventional shoulder MR arthrography (MRA) images. Material and Methods Thirty-seven shoulder MRA images acquired by synthetic MRI were retrospectively evaluated for PD, T1, and T2 values at the joint fluid and glenoid labrum. Differences in signal intensity between the fluid and labrum were observed between TR of 500-6000 ms and TE of 80-300 ms in T2-weighted (T2W) images. Conventional T2W and synthetic images were analyzed for diagnostic agreement of supraspinatus tendon abnormalities (kappa statistics) and image quality scores (one-way analysis of variance with post-hoc analysis). Results Optimized mean values of TR and TE were 2724.7 ± 1634.7 and 80.1 ± 0.4, respectively. Diagnostic agreement for supraspinatus tendon abnormalities between conventional and synthetic MR images was excellent (κ = 0.882). The mean image quality score of the joint space in optimized synthetic images was significantly higher compared with those in conventional and synthetic images (2.861 ± 0.351 vs. 2.556 ± 0.607 vs. 2.750 ± 0.439; P optimized TR and TE for shoulder MRA enables optimization of soft-tissue contrast.

  17. Ankle ligamints : comparison of MR arthrography with conventional MR imaging in amputated feet

    International Nuclear Information System (INIS)

    Yoo, Jae Sung; Lee, Sang Yong; Lee, Jeong Min; Han, Young Min; Chung, Kyung Ho; Kim, CHong Soo

    2001-01-01

    To compare magnetic resonance (MR) arthrography with conventional MR imaging in the evaluation of ankle ligaments. Eight freshly amputated human feet underwent conventional MR imaging and MR arthrography. For the former, 1.5-T magnets in the axial, coronal and sagittal planes were used, and T1-weighted sequences were obtained. Following the injection of 6-10 ml of diluted contrast media (Gd-DTPA 1:250), T1-weighted images were obtained in the same positions as conventional MR images. Paired conventional MR imaging and MR arthrography of each ankle ligament were rated on a five-point scale, and to reflect inter-group differences a Wilcoxon singed-rank test was used to compare the different measurements (p<0.05). In two ankles, MR images of the ligaments were correlated with ankle dissection. Anterior and posterior talofibular ligaments were more clearly revealed by MR arthrography than by conventional MR imaging, while calcaneofibular ligaments showed no difference between these two modalities. With regard to deltoid ligaments, visualization of the anterior and posterior tibiotalar ligament was much improved when contrast material was used to outline the ligament's articular aspect. Visualization of the posterior inferior tibiofibular ligament and inferior transverse ligament were also improved when the use of contrast material provided delineation of the articular side of the ligaments and separated them from adjacent bone. In addition, MR arthography was very useful for indentification of the posterior intermalleolar ligament, though its use did not enhance visualization of the calcaneofibular, tibiocalcaneal, spring or tibiospring ligaments. MR arthrography accurately revealed the anatomic details of ankle ligaments, and may therefore be more useful than conventional Mr imaging for evaluation of these structures

  18. Rotator cuff tears noncontrast MRI compared to MR arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ji Hyun; Yoon, Young Cheol [Sungkyunkwan University, School of Medicine, Department of Radiology, Samsung Medical Center, Gangnam-gu, Seoul (Korea, Republic of); Jung, Jee Young [Chungang University School of Medicine, Department of Radiology, Chungang University Hospital, Seoul (Korea, Republic of); Yoo, Jae Chul [Sungkyunkwan University, School of Medicine, Department of Orthopedic Surgery, Samsung Medical Center, Seoul (Korea, Republic of)

    2015-12-15

    To compare the accuracy of indirect magnetic resonance arthrography and noncontrast magnetic resonance imaging for diagnosing rotator cuff tears. In total, 333 patients who underwent noncontrast magnetic resonance imaging or indirect magnetic resonance arthrography were included retrospectively. Two musculoskeletal radiologists evaluated the images for the presence of supraspinatus-infraspinatus and subscapularis tendon tears. The overall diagnostic performance was calculated using the arthroscopic findings as the reference standard. Statistical differences between the diagnostic performances of the two methods were analyzed. Ninety-six and 237 patients who underwent noncontrast magnetic resonance imaging and indirect magnetic resonance arthrography were assigned into groups A and B, respectively. Sensitivity for diagnosing articular-surface partial-thickness supraspinatus-infraspinatus tendon tear was slightly higher in group B than in group A. Statistical significance was confirmed by multivariate analysis using the generalized estimating equation (p = 0.046). The specificity for diagnosing subscapularis tendon tear (85 % vs. 68 %, p = 0.012) and grading accuracy (57 % vs. 40 %, p = 0.005) was higher in group B than in group A; the differences were statistically significant for one out of two readers. Univariate analysis using the generalized estimating equation showed that the accuracy for diagnosing subscapularis tendon tear in group B was higher than in group A (p = 0.042). There were no statistically significant differences between the diagnostic performances of both methods for any other parameters. Indirect magnetic resonance arthrography may facilitate more accurate diagnosis and grading of subscapularis tendon tears compared with noncontrast magnetic resonance imaging. (orig.)

  19. Rotator cuff tears noncontrast MRI compared to MR arthrography

    International Nuclear Information System (INIS)

    Lee, Ji Hyun; Yoon, Young Cheol; Jung, Jee Young; Yoo, Jae Chul

    2015-01-01

    To compare the accuracy of indirect magnetic resonance arthrography and noncontrast magnetic resonance imaging for diagnosing rotator cuff tears. In total, 333 patients who underwent noncontrast magnetic resonance imaging or indirect magnetic resonance arthrography were included retrospectively. Two musculoskeletal radiologists evaluated the images for the presence of supraspinatus-infraspinatus and subscapularis tendon tears. The overall diagnostic performance was calculated using the arthroscopic findings as the reference standard. Statistical differences between the diagnostic performances of the two methods were analyzed. Ninety-six and 237 patients who underwent noncontrast magnetic resonance imaging and indirect magnetic resonance arthrography were assigned into groups A and B, respectively. Sensitivity for diagnosing articular-surface partial-thickness supraspinatus-infraspinatus tendon tear was slightly higher in group B than in group A. Statistical significance was confirmed by multivariate analysis using the generalized estimating equation (p = 0.046). The specificity for diagnosing subscapularis tendon tear (85 % vs. 68 %, p = 0.012) and grading accuracy (57 % vs. 40 %, p = 0.005) was higher in group B than in group A; the differences were statistically significant for one out of two readers. Univariate analysis using the generalized estimating equation showed that the accuracy for diagnosing subscapularis tendon tear in group B was higher than in group A (p = 0.042). There were no statistically significant differences between the diagnostic performances of both methods for any other parameters. Indirect magnetic resonance arthrography may facilitate more accurate diagnosis and grading of subscapularis tendon tears compared with noncontrast magnetic resonance imaging. (orig.)

  20. MR arthrography: how I do it

    International Nuclear Information System (INIS)

    Bankaoglu, M.

    2012-01-01

    Full text: Magnetic resonance imaging has to rely on improving new various sequences and techniques and to get the best imaging quality so magnetic resonance (MR) arthrography is one of the most important technique in the assessment of selected musculoskeletal disorders. It is now widely utilized and considered by most musculoskeletal radiologists and some orthopedists to be an integral part of their clinical practice. The technique include: desired degree of joint distension with contrast medium; markedly improved imaging quality of intra-articular structures with the direct delineation so improved detection of pathology with MRI. As appliance and technique of MR arthrography is completely based on traditional arthrography of X ray. In MR arthrography additional very little amount of Gadolinium based contrast agent is added to the desired mixture of contrast material injected to the joint. As in conventional radiography MR arthrography is used to get extra information for conventional MRI . Practically any joint that can be accessed by a needle can be imaged using MR arthrography but it has been applied to limited number of joints to compare with the traditional arthrography so shoulder, knee, wrist, elbow, ankle, and hip are mostly subjects to do in MR arthrography. The procedure is also less invasive and expensive rather than diagnostic arthroscopy and should carefully indicated because it is not completely noninvasive technique so previous imaging modalities and MRI of the patients should be completed and evaluated well. During or after the procedure there has been no major complication reported by so far but more than two third of patients are known to complain some degree of pain right after or several times later than the procedure. As it is more than twenty years now it has been widely accepted helpful for diagnosis and adds some extra sensitivity to conventional MRI . Up to this time MR arthrography has proven to increase sensitivity of conventional MRI in

  1. Detection and staging of chondromalacia patellae: relative efficacies of conventional MR imaging, MR arthrography, and CT arthrography.

    Science.gov (United States)

    Gagliardi, J A; Chung, E M; Chandnani, V P; Kesling, K L; Christensen, K P; Null, R N; Radvany, M G; Hansen, M F

    1994-09-01

    Chondromalacia patellae is a condition characterized by softening, fraying, and ulceration of patellar articular cartilage. We compare the sensitivity, specificity, and accuracy of conventional MR imaging, MR arthrography, and CT arthrography in detecting and staging this abnormality. Twenty-seven patients with pain in the anterior part of the knee were prospectively examined with MR imaging, including T1-weighted (650/16), proton density-weighted (2000/20), T2-weighted (2000/80), and spoiled two-dimensional gradient-recalled acquisition in the steady state (SPGR/)/35 degrees (51/10) with fat saturation pulse sequences. All were also examined with T1-weighted MR imaging after intraarticular injection of dilute gadopentetate dimeglumine and with double-contrast CT arthrography. Each imaging technique was evaluated independently by two observers, who reached a consensus interpretation. The signal characteristics of cartilage on MR images and contour abnormalities noted with all imaging techniques were evaluated and graded according to a modification of the classification of Shahriaree. Twenty-six of the 54 facets examined had chondromalacia shown by arthroscopy, which was used as the standard of reference. The sensitivity, specificity, and accuracy of each imaging technique in the diagnosis of each stage of chondromalacia patellae were determined and compared by using the McNemar two-tailed analysis. Arthroscopy showed that 28 facets were normal. Grade 1 chondromalacia patellae was diagnosed only with MR and CT arthrography in two (29%) of seven facets. Intermediate (grade 2 or 3) chondromalacia patellae was detected in two (13%) of 15 facets with T1-weighted and SPGR MR imaging, in three (20%) of 15 facets with proton density-weighted MR imaging, in seven (47%) of 15 facets with T2-weighted MR imaging, in 11 (73%) of 15 facets with CT arthrography, and in 12 (80%) of 15 facets with MR arthrography. Grade 4 was detected in three (75%) of four facets with T1-, proton

  2. T2[sup *] weighted MR imaging for the diagnosis of the perforation of triangular fibrocartilage; Comparison with arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Taro; Nakamura, Eiziro; Ahsoh, Kuniichi; Masumi, Shogo (Oita Medical Univ., Takatsuki (Japan))

    1994-05-01

    Perforation of the triangular fibrocartilage (TFC) has been considered an important factor in the etiology of pain in the ulnar wrist joint, and arthrography has been used conventionally to diagnose the perforation. Recently, magnetic resonance imaging (MRI) has been used to diagnose TFC perforation. Gundy et al. examined cadaver wrists with Tl weighted imaging and arthrography, and obtained findings suggesting that arthrography provides a more accurate diagnosis of the TFC perforation. To our knowledge, no comparison has yet been made between T2[sup *] weighted imaging and arthrography in the diagnosis of TFC perforation. The present study compared the usefulness of T2[sup *]-weighted imaging and arthrography in the diagnosis of TFC perforation in 22 wrist joints of 11 cadavers (5 males and 6 females with ages ranging from 61 to 92 years and an average age of 78.8 years) fixed in 60% formalin. The specimens were firstly analyzed by a T2[sup *]-weighted 0.5T MRI scan and subsequently by arthrography. After diagnosing the image obtained by the two methods, the accuracy of the diagnosis was determined by comparison with the macroscopic findings of autopsy, including the presence and degree of TFC perforation. A T2[sup *]-weighted MRI scan of the TFC perforation showed high-intensity areas over the distal radio-ulnar joint, and demonstrated the same diagnostic accuracy as arthrography, providing correct diagnoses in all cases other than linear perforation. However, neither of the image diagnostic methods allowed definition of the type of perforation. (author).

  3. Tears of the Supraspinatus Tendon: Assessment with Indirect Magnetic Resonance Arthrography in 67 Patients with Arthroscopic Correlation

    International Nuclear Information System (INIS)

    Dyck, P. van; Gielen, J.L.; Parizel, P.M.

    2009-01-01

    Background: Magnetic resonance (MR) arthrography is generally regarded as the gold standard for shoulder imaging. As an alternative to direct MR arthrography, the less invasive indirect MR arthrography technique was proposed, offering logistic advantages because fluoroscopic or ultrasonographic guidance for joint injection is not required. Purpose: To assess the diagnostic performance of indirect MR arthrography in the diagnosis of full- and partial-thickness supraspinatus tears in a symptomatic population. Material and Methods: Two radiologists with different levels of experience independently and retrospectively interpreted indirect MR (1.5T) arthrograms of the shoulder obtained in 67 symptomatic patients who underwent subsequent arthroscopy. On MR, the supraspinatus tendon was evaluated for full- or partial-thickness tear. With arthroscopy as the standard of reference, sensitivity, specificity, and diagnostic accuracy of indirect MR arthrography in the detection of full- and partial-thickness tears of the supraspinatus tendon was calculated. Kappa (κ) statistics were used for the assessment of the agreement between arthroscopic and imaging findings and for the assessment of interobserver agreement. Results: For full-thickness tears of the supraspinatus tendon, sensitivities, specificities, and accuracies exceeded 90% for both observers, with excellent interobserver agreement (κ = 0.910). For partial-thickness tears, sensitivities (38-50%) and accuracies (76-78%) were poor for both reviewers, and interobserver agreement was moderate (κ = 0.491). Discrepancies between MR diagnosis and arthroscopy were predominantly observed with small partial-thickness tears. Conclusion: Indirect MR arthrography is highly accurate in the diagnosis of full-thickness rotator cuff tears. However, the diagnosis of partial-thickness tears with indirect MR arthrography remains faulty, because exact demarcation of degenerative change and partial rupture is difficult. On the basis of

  4. Tears of the Supraspinatus Tendon: Assessment with Indirect Magnetic Resonance Arthrography in 67 Patients with Arthroscopic Correlation

    Energy Technology Data Exchange (ETDEWEB)

    Dyck, P. van; Gielen, J.L.; Parizel, P.M. (Dept. of Radiology, Univ. Hospital Antwerp and Univ. of Antwerp, Antwerp (Belgium)) (and others)

    2009-11-15

    Background: Magnetic resonance (MR) arthrography is generally regarded as the gold standard for shoulder imaging. As an alternative to direct MR arthrography, the less invasive indirect MR arthrography technique was proposed, offering logistic advantages because fluoroscopic or ultrasonographic guidance for joint injection is not required. Purpose: To assess the diagnostic performance of indirect MR arthrography in the diagnosis of full- and partial-thickness supraspinatus tears in a symptomatic population. Material and Methods: Two radiologists with different levels of experience independently and retrospectively interpreted indirect MR (1.5T) arthrograms of the shoulder obtained in 67 symptomatic patients who underwent subsequent arthroscopy. On MR, the supraspinatus tendon was evaluated for full- or partial-thickness tear. With arthroscopy as the standard of reference, sensitivity, specificity, and diagnostic accuracy of indirect MR arthrography in the detection of full- and partial-thickness tears of the supraspinatus tendon was calculated. Kappa (kappa) statistics were used for the assessment of the agreement between arthroscopic and imaging findings and for the assessment of interobserver agreement. Results: For full-thickness tears of the supraspinatus tendon, sensitivities, specificities, and accuracies exceeded 90% for both observers, with excellent interobserver agreement (kappa = 0.910). For partial-thickness tears, sensitivities (38-50%) and accuracies (76-78%) were poor for both reviewers, and interobserver agreement was moderate (kappa = 0.491). Discrepancies between MR diagnosis and arthroscopy were predominantly observed with small partial-thickness tears. Conclusion: Indirect MR arthrography is highly accurate in the diagnosis of full-thickness rotator cuff tears. However, the diagnosis of partial-thickness tears with indirect MR arthrography remains faulty, because exact demarcation of degenerative change and partial rupture is difficult. On the

  5. Magnetic resonance imaging and magnetic resonance arthrography of the shoulder: dependence on the level of training of the performing radiologist for diagnostic accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Theodoropoulos, John S. [University of Toronto, Division of Orthopaedics, Mount Sinai Hospital and the University Health Network, Toronto, ON (Canada); Andreisek, Gustav [University of Toronto, Department of Medical Imaging, Mount Sinai Hospital and the University Health Network, Toronto, ON (Canada); University Hospital Zuerich, Institute for Diagnostic Radiology, Zuerich (Switzerland); Harvey, Edward J. [McGill University, Division of Orthopaedics, MUHC - Montreal General Hospital, Montreal, Quebec (Canada); Wolin, Preston [Center for Athletic Medicine, Chicago, IL (United States)

    2010-07-15

    Discrepancies were identified between magnetic resonance (MR) imaging and clinical findings in patients who had MR imaging examinations evaluated by community-based general radiologists. The purpose of this study was to evaluate the diagnostic performance of MR imaging examinations of the shoulder with regard to the training level of the performing radiologist. A review of patient charts identified 238 patients (male/female, 175/63; mean age, 40.4 years) in whom 250 arthroscopies were performed and who underwent MR imaging or direct MR arthrography in either a community-based or hospital-based institution prior to surgery. All MR imaging and surgical reports were reviewed and the diagnostic performance for the detection of labral, rotator cuff, biceps, and Hill-Sachs lesions was determined. Kappa and Student's t test analyses were performed in a subset of cases in which initial community-based MR images were re-evaluated by hospital-based musculoskeletal radiologists, to determine the interobserver agreement and any differences in image interpretation. The diagnostic performance of community-based general radiologists was lower than that of hospital-based sub-specialized musculoskeletal radiologists. A sub-analysis of re-evaluated cases showed that musculoskeletal radiologists performed better. {kappa} values were 0.208, 0.396, 0.376, and 0.788 for labral, rotator cuff, biceps, and Hill-Sachs lesions (t test statistics: p =<0.001, 0.004, 0.019, and 0.235). Our results indicate that the diagnostic performance of MR imaging and MR arthrography of the shoulder depends on the training level of the performing radiologist, with sub-specialized musculoskeletal radiologists having a better diagnostic performance than general radiologists. (orig.)

  6. Arthrography

    Medline Plus

    Full Text Available ... risks? What are the limitations of Direct Arthrography? What is Direct Arthrography? Arthrography is medical imaging to ... a computer using x-rays. top of page What are some common uses of the procedure? Arthrographic ...

  7. Imaging diagnostics of the wrist: MRI and Arthrography/Arthro-CT; Bildgebende Diagnostik des Handgelenkes: MRT und Arthrographie/Arthro-CT

    Energy Technology Data Exchange (ETDEWEB)

    Klein, H.M.; Balas, R.; Neugebauer, F. [Radiologische Gemeinschaftspraxis, Betzdorf (Germany); Vrsalovic, V. [Handchirugie, Marienhospital Siegen, Siegen (Germany)

    2002-02-01

    Purpose: To evaluate the use of magnetic resonance imaging (MRI) compared with arthrography and arthro-CT (AG/ACT) in patients with wrist pain. Methods: MRI and arthrography/arthro-CT (AG/ACT) of the wrist joint were retrospectively evaluated in 346 patients over a three-year period. Imaging findings were correlated to surgical results (n=78) or clinical course in an at least 6-month follow-up. Results: For tears of the triangular fibrocartilage, arthrography, arthro-CT, and MRI demonstrated a sensitivity and specificity of more than 0.96. Only the positive predictive value was superior for arthrography/arthro-CT (0.99 and 0.98, respectively) compared with MRI (0.94). Arthrography was superior for functional diagnosis of scapho-lunate ligament tears (n=25). Ulno-lunate and ulno-triquetral ligament defects were demonstrated more exactly by arthrography. Traumatic osseous defects, particularly scaphoid fractures (n=33) and avascular necrosis (n=17), were better diagnosed using MRI. Conclusion: For suspected lesions of the triangular fibrocartilage complex, AG/ACT is slightly more reliable than MRI. However, MRI was found to be highly accurate in diagnosing TFC tears, and is superior to AG/ACT in detecting traumatic and vascular lesions of the wrist. (orig.) [German] Ziel: Die Untersuchung der diagnostischen Aussagekraft von Magnetresonanz-Tomographie (MRT), Arthrographie (AG) und Arthro-CT (ACT) bei Erkrankungen des Handgelenkes. Methodik: Insgesamt 346 Untersuchungen des Handgelenkes wurden fuer einen dreijaehrigen Beobachtungszeitraum retrospektiv ausgewertet. Es wurden 211 MRT, 151 Arthrographien (AG) und 126 Arthro-CT (ACT) durchgefuehrt. Alle Diagnosen wurden operativ (n=78) oder durch den klinischen Verlauf in einer 6-monatigen Nachbeobachtung gesichert. Ergebnisse: Fuer die Diagnostik von Laesionen des diskoulnaren Komplexes lag die Sensitivitaet und Spezifitaet von AG, ACT und MRT ueber 0,96. Lediglich der positive Vorhersagewert differierte, allerdings nicht

  8. Diagnostic value of MRI in meniscus injury. Comparison of MRI and arthrography

    International Nuclear Information System (INIS)

    Iso, Yoshinori; Nozaki, Hiroyuki; Emoto, Mari; Miyairi, Taro; Hirata, Aya; Hirasawa, Seiichi; Suguro, Toru; Igata, Atsuomi; Kudo, Yukihiko.

    1995-01-01

    Magnetic resonance imaging (MRI) and arthrography were performed on 90 knees to compare the diagnostic value for meniscus injury with these techniques. The diagnostic accuracy of MRI and arthrography was 89.1% and 87.1%, respectively. Imaging of the medial meniscus was somewhat better with arthrography, and delineation of the lateral meniscus was somewhat better with MRI. MRI was superior in diagnoses of horizontal and degenerative lacerations, but showed the shape of the injuries less clearly than arthrography. The diagnostic accuracy of MRI decreased with the age of the patients and was inferior to arthrography for patients in their forties or older. In conclusion, MRI is a less invasive approach with high diagnostic accuracy for meniscus injury and is a promising substitute for arthrography. (author)

  9. MR-guided direct arthrography of the glenohumeral joint

    International Nuclear Information System (INIS)

    Soh, E.; Bearcroft, P.W.P.; Graves, M.J.; Black, R.; Lomas, D.J.

    2008-01-01

    Aim: To evaluate the feasibility of magnetic resonance (MR)-guided direct arthrography of the glenohumeral joint with a 1.5 T MR system, performing the entire procedure in a single MR examination. Materials and methods: MR-guided direct arthrography was performed on 11 patients. MR imaging guidance and interactive MR fluoroscopy, with in-room control and display system, were used for needle placement and contrast medium injection. The outcome measures were success or failure of joint puncture, the time taken for introduction of contrast medium, and the diagnostic quality of the subsequent MR arthrography images. Results: Contrast medium was successfully instilled into the joint and diagnostic quality MR arthrography images were obtained in all cases. The median time from initial placement of the skin marker to introduction of the contrast medium was 17 min (range 11-29 min). There were no immediate post-procedure complications. Conclusion: Accurate needle placement is feasible in a single MR examination on a commercial 1.5 T closed-bore MR system, using an in-room control and display system together with interactive fluoroscopic imaging, and this was used to provide direct MR arthrography in this study

  10. Direct magnetic resonance arthrography of the canine elbow

    Directory of Open Access Journals (Sweden)

    Yauheni Zhalniarovich

    2017-01-01

    Full Text Available This study compares the effects of four dilutions of the gadolinium-containing contrast media (1:100; 1:400; 1:800; 1:1,200 administered to the elbow on the quality of magnetic resonance images. All the examined dilutions had a positive effect on image quality, and 1:800 was regarded as the optimal dilution of gadolinium for viewing the elbow because it imparted good contrast to the joint cavity without obliterating the contours of articular surfaces. Transverse, sagittal, and dorsal low-field magnetic resonance images were obtained in 24 canine cadaver front limbs. The musculus biceps brachii, m. triceps brachii, m. extensor carpi radialis, m. flexor carpi ulnaris, the articular surfaces, the medial coronoid process and the anconeal process of the ulna were well visualized by High Resolution Gradient Echo, XBONE T2 and Spin Echo T1 sequences in the sagittal plane. The biceps brachii, pronator teres, flexor carpi radialis, extensor digitorum communis, extensor carpi radialis, deltoid muscle and the articular surface of the medial condyle of the humerus were very well visualized by 3D SST1 and XBONE T2 sequences in the transverse plane. The triceps brachii muscle, extensor digitorum lateralis muscle, superficial digital flexor, deep digital flexor and the medial condyle of the humerus were very well visualized by the Spin Echo T1 sequence in the dorsal plane. This article describes for the first time the use of the gadolinium contrast agent administered to the canine elbow joint during magnetic resonance modality. Magnetic resonance arthrography can be a helpful visualization technique in treating canine soft tissue elbow injury.

  11. The diagnostic accuracy of acetabular labral tears using magnetic resonance imaging and magnetic resonance arthrography: a meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Toby O. [University of East Anglia, Faculty of Health, Queen' s Building, Norwich (United Kingdom); Hilton, Gemma [Norfolk and Norwich University Hospital, Norwich (United Kingdom); Toms, Andoni P.; Donell, Simon T. [Norfolk and Norwich University Hospital, University of East Anglia, Norwich (United Kingdom); Hing, Caroline B. [St. George' s Hospital, London (United Kingdom)

    2011-04-15

    Magnetic resonance imaging (MRI) and magnetic resonance arthrography (MRA) have been advocated for the diagnosis of acetabular labral tears. The purpose of this study was to determine the sensitivity and specificity of MRI and MRA in diagnosing acetabular labral tears using meta-analysis. Pertinent published and unpublished literature databases were reviewed. A two-by-two table was constructed to calculate the sensitivity and specificity of MRI or MRA investigations against surgical outcomes. Pooled sensitivity and specificity and Receiver Operating Characteristic curve (ROC) evaluations were performed. Methodological quality of each study was assessed using the QUADAS (Quality Assessment of Diagnostic Accuracy Studies) tool. Nineteen papers assessing 881 hips were reviewed. Conventional MRI was assessed in 13 studies and MRA was assessed in 16 studies. Whilst both MRI (0.5-3T) and MRA (0.5-3T) presented with a moderate sensitivity and specificity (sensitivity 66%, 87%; specificity 79%, 64%), diagnostic accuracy of MRA appeared to be superior to MRI in detecting acetabular labral tears on ROC curve interpretation. The literature poorly described population characteristics, assessor blinding, with limited sample sizes. MRI and MRA may be useful adjuncts in the diagnosis of acetabular labral tears in adults. MRA appears to be superior to conventional MRI. (orig.)

  12. Triple correlation in temporomandibular joint dysfunction: MR imaging with arthrography, arthroscopy, and open surgery

    International Nuclear Information System (INIS)

    Rao, V.M.; Farole, A.; Karasick, D.

    1988-01-01

    Triple correlation of MR imaging with arthrography, arthroscopy, and open surgery was performed in 24 patients (34 temporomandibular joints) with ages ranging from 17 to 66 years. MR imaging showed disk position and morphologic features accurately in 30 joints (88%). It was false negative in one joint and false positive in three joints (9%). Degenerative changes were accurately detected with MR imaging, arthrography, and arthroscopy. Adhesions were diagnosed with arthrography in eight joints, arthroscopy in 14, and MR imaging in none. Disk perforations seen at open surgery were not detected with MR imaging. In conclusion, there is an overlap of information presented by various modalities. MR imaging is better than arthrography detecting disk morphologic features and displacement. Arthrography may add information by showing meniscal dynamics. Arthroscopy entails direct observation of superior joint space only and can detect adhesions and perforations better, but it may alter disk position and dynamics. In the more difficult cases, triple correlation may be needed, as modalities can be complementary

  13. Arthrography

    Medline Plus

    Full Text Available ... large film sheets (much like a large photographic negative). Today, most images are digital files that are ... limitations of arthrography? The limitations of arthrography include: Partial tears of the rotator cuff may not be ...

  14. Arthrography

    Medline Plus

    Full Text Available ... Your preparation may vary depending on which imaging method your exam will use. Tell your doctor if ... in assessing a joint abnormality. There are several methods to perform direct arthrography. Conventional direct arthrography of ...

  15. Arthrography

    Medline Plus

    Full Text Available ... Z Direct Arthrography Arthrography is a type of medical imaging used to help evaluate and diagnose joint ... you are pregnant and discuss any recent illnesses, medical conditions, medications you’re taking, and allergies – especially ...

  16. Comparison of conventional MRI and MR arthrography in the evaluation of wrist ligament tears: A preliminary experience

    Science.gov (United States)

    Pahwa, Shivani; Srivastava, Deep N; Sharma, Raju; Gamanagatti, Shivanand; Kotwal, Prakash P; Sharma, Vijay

    2014-01-01

    Aims: To compare conventional magnetic resonance imaging (MRI) and direct magnetic resonance (MR) arthrography in the evaluation of triangular fibrocartilage complex (TFCC) and intrinsic wrist ligament tears. Materials and Methods: T1-weighted, fat suppressed (FS) proton density plus T2-weighted (FS PD/T2), 3D multiple-echo data image combination (MEDIC) sequences and direct MR arthrography were performed in 53 patients with wrist pain. Images were evaluated for the presence and location of TFCC, scapholunate ligament (SLL) and lunatotriquetral ligament (LTL) tears, and imaging findings were compared with operative findings in 16 patients who underwent arthroscopy or open surgery (gold standard). Results: Sixteen patients underwent arthroscopy/open surgery: 12 TFCC tears were detected arthroscopically out of which 9 were detected on FS PD/T2 sequence, 10 on MEDIC sequence, and all 12 were detected on MR arthrography. The sensitivities of FS PD/T2, MEDIC sequences, and MR arthrography in the detection of TFCC tears were 75%, 83.3%, and 100%, respectively. Out of the eight arthroscopically confirmed SLL tears, three tears were detected on FS PD/T2 sequence, five on MEDIC sequence, and all eight were visualized on MR arthrography. The sensitivities of FS PD/T2, MEDIC sequences, and MR arthrography in detecting SLL tears were 37.5%, 62.5%, and 100%, respectively. One arthroscopically confirmed LTL tear was diagnosed on FS PD/T2 sequence, three on MEDIC sequence, and all five arthroscopically confirmed LTL tears were detected with MR arthrography. The sensitivities of PD, MEDIC sequences, and MR arthrography in detecting LTL tears were 20%, 40%, and 100%, respectively. Conclusions: MR arthrography is the most sensitive and specific imaging modality for the evaluation of wrist ligament tears. PMID:25114389

  17. Comparison of conventional MRI and MR arthrography in the evaluation of wrist ligament tears: A preliminary experience

    Directory of Open Access Journals (Sweden)

    Shivani Pahwa

    2014-01-01

    Full Text Available Aims: To compare conventional magnetic resonance imaging (MRI and direct magnetic resonance (MR arthrography in the evaluation of triangular fibrocartilage complex (TFCC and intrinsic wrist ligament tears. Materials and Methods: T1-weighted, fat suppressed (FS proton density plus T2-weighted (FS PD/T2, 3D multiple-echo data image combination (MEDIC sequences and direct MR arthrography were performed in 53 patients with wrist pain. Images were evaluated for the presence and location of TFCC, scapholunate ligament (SLL and lunatotriquetral ligament (LTL tears, and imaging findings were compared with operative findings in 16 patients who underwent arthroscopy or open surgery (gold standard. Results: Sixteen patients underwent arthroscopy/open surgery: 12 TFCC tears were detected arthroscopically out of which 9 were detected on FS PD/T2 sequence, 10 on MEDIC sequence, and all 12 were detected on MR arthrography. The sensitivities of FS PD/T2, MEDIC sequences, and MR arthrography in the detection of TFCC tears were 75%, 83.3%, and 100%, respectively. Out of the eight arthroscopically confirmed SLL tears, three tears were detected on FS PD/T2 sequence, five on MEDIC sequence, and all eight were visualized on MR arthrography. The sensitivities of FS PD/T2, MEDIC sequences, and MR arthrography in detecting SLL tears were 37.5%, 62.5%, and 100%, respectively. One arthroscopically confirmed LTL tear was diagnosed on FS PD/T2 sequence, three on MEDIC sequence, and all five arthroscopically confirmed LTL tears were detected with MR arthrography. The sensitivities of PD, MEDIC sequences, and MR arthrography in detecting LTL tears were 20%, 40%, and 100%, respectively. Conclusions: MR arthrography is the most sensitive and specific imaging modality for the evaluation of wrist ligament tears.

  18. Ultrasound guidance to perform intra-articular injection of gadolinium-based contrast material for magnetic resonance arthrography as an alternative to fluoroscopy: the time is now

    Energy Technology Data Exchange (ETDEWEB)

    Messina, Carmelo [Universita degli Studi di Milano, Scuola di Specializzazione in Radiodiagnostica, Milano (Italy); Banfi, Giuseppe [IRCCS Istituto Ortopedico Galeazzi, Milano (Italy); Universita Vita-Salute San Raffaele, Milano (Italy); Aliprandi, Alberto [Universita degli Studi di Milano, Dipartimento di Scienze Biomediche per la Salute, Milano (Italy); Mauri, Giovanni [Universita degli Studi di Milano, Dipartimento di Scienze Biomediche per la Salute, Milano (Italy); Istituto Europeo di Oncologia, Unita di Radiologia Interventistica, Milano (Italy); Secchi, Francesco; Sardanelli, Francesco; Sconfienza, Luca Maria [Universita degli Studi di Milano, Dipartimento di Scienze Biomediche per la Salute, Milano (Italy); IRCCS Policlinico San Donato, Servizio di Radiologia, San Donato, Milanese (Italy)

    2016-05-15

    Magnetic resonance (MR) imaging has been definitively established as the reference standard in the evaluation of joints in the body. Similarly, magnetic resonance arthrography has emerged as a technique that has been proven to increase significantly the diagnostic performance if compared with conventional MR imaging, especially when dealing with fibrocartilage and articular cartilage abnormalities. Diluted gadolinium can be injected in the joint space using different approaches: under palpation using anatomic landmarks or using an imaging guidance, such as fluoroscopy, computed tomography, or ultrasound. Fluoroscopy has been traditionally used, but the involvement of ionizing radiation should represent a remarkable limitation of this modality. Conversely, ultrasound has emerged as a feasible, cheap, quick, and radiation-free modality that can be used to inject joints, with comparable accuracy of fluoroscopy. In the present paper, we discuss the advantages and disadvantages of using fluoroscopy or ultrasound in injecting gadolinium-based contrast agents in joints to perform magnetic resonance arthrography, also in view of the new EuroSAFE Imaging initiative promoted by the European Society of Radiology and the recent updates to the European Atomic Energy Community 2013/59 directive on the medical use of ionizing radiation. (orig.)

  19. MRI and arthrography in the evaluation of TMJ disorders

    International Nuclear Information System (INIS)

    Nakasato, Tatsuhiko; Ehara, Shigeru; Tamakawa, Yoshiharu; Kobayakawa, Takafumi.

    1991-01-01

    Arthrosis of the temporomandibular joint (TMJ) is a noninfectious, noninflammatory condition characterized by joint pain, noise (clicking) and abnormal motion. It contains various disease processes, such as abnormalities in the menisci or masticating muscles, subluxation of the condyle and degenerative joint disease. Analysis of the morphology and dynamics of TMJ by means of imaging modalities has become highly advanced since the development of arthrography in the late 1970s. Magnetic resonance imaging (MRI) has become the modality of choice in the evaluation of TMJ owing to the development of surface coils. We retrospectively studied MRI and inferior joint compartment arthrography in the evaluation of TMJ disorders. Nineteen joints of 14 patients included 15 with internal derangement, two with osteoarthrosis and two normal joints. Sagittal MR images were routinely obtained in a resting position and in positions with the mouth half open, and also with the mouth fully open on balanced images. Although perforation of the menisci was difficult to evaluate, MRI and arthrography were equally useful in identifying the shape and position of the meniscus. However, MRI was more reliable in depicting TMJ abnormalities than arthrography. MRI is considered to be the modality of choice in screening arthrosis of TMJ, making the definitive diagnosis of internal derangement and monitoring conservative therapy for arthrosis. (author)

  20. MRI and arthrography in the evaluation of TMJ disorders

    Energy Technology Data Exchange (ETDEWEB)

    Nakasato, Tatsuhiko; Ehara, Shigeru; Tamakawa, Yoshiharu (Iwate Medical Univ., Morioka (Japan). School of Medicine); Kobayakawa, Takafumi

    1991-08-01

    Arthrosis of the temporomandibular joint (TMJ) is a noninfectious, noninflammatory condition characterized by joint pain, noise (clicking) and abnormal motion. It contains various disease processes, such as abnormalities in the menisci or masticating muscles, subluxation of the condyle and degenerative joint disease. Analysis of the morphology and dynamics of TMJ by means of imaging modalities has become highly advanced since the development of arthrography in the late 1970s. Magnetic resonance imaging (MRI) has become the modality of choice in the evaluation of TMJ owing to the development of surface coils. We retrospectively studied MRI and inferior joint compartment arthrography in the evaluation of TMJ disorders. Nineteen joints of 14 patients included 15 with internal derangement, two with osteoarthrosis and two normal joints. Sagittal MR images were routinely obtained in a resting position and in positions with the mouth half open, and also with the mouth fully open on balanced images. Although perforation of the menisci was difficult to evaluate, MRI and arthrography were equally useful in identifying the shape and position of the meniscus. However, MRI was more reliable in depicting TMJ abnormalities than arthrography. MRI is considered to be the modality of choice in screening arthrosis of TMJ, making the definitive diagnosis of internal derangement and monitoring conservative therapy for arthrosis. (author).

  1. The Role of Wrist Magnetic Resonance Arthrography in Diagnosing Triangular Fibrocartilage Complex Tears; Experience at King Hussein Medical Center, Jordan

    Directory of Open Access Journals (Sweden)

    Asem A. Al-Hiari

    2013-05-01

    Full Text Available Objectives: The aims of the study were to evaluate the role of magnetic resonance arthrography (MRA of the wrist in detecting full-thickness tears of the triangular fibrocartilage complex (TFCC and to compare the results of the magnetic resonance arthrography (MRA with the gold standard arthroscopic findings. Methods:The study was performed at King Hussein Medical Center, Amman, Jordan, between January 2008 and December 2011. A total of 42 patients (35 males and 7 females who had ulnar-sided wrist pain and clinical suspicions of TFCC tears were included in the study. All patients underwent wrist magnetic resonance arthrography (MRA and then a wrist arthroscopy. The results of MRA were compared with the arthroscopic findings. Results: After comparison with the arthroscopic findings, the MRA had three false-negative results (sensitivity = 93% and no false-positive results. A total of 39 patients were able to return to work. Satisfaction was high in 38 of the patients and 33 had satisfactorypain relief. The sensitivity of the wrist MRA in detecting TFCC full-thickness tears was 93% (39, and specificity was 80% (16/20. The overall accuracy of wrist arthroscopy in detecting a full-thickness tear of the TFCC in our study was 85% (29/34. Conclusion: These results illustrate the role of wrist MRA in assessing the TFCC pathology and suggest its use as the first imaging technique, following a plain X-ray, in evaluating patients with chronic ulnar side wrist pain with suspected TFCC injuries.

  2. Diagnostic Accuracy and Inter-Observer Agreement of Shoulder Magnetic Resonance Arthrography in the Detection of Labral Lesion and Assessment of Lesion Location

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Ji Young; Song, Sook Yun; Choi, Jin Ha; Shin, Sang Jin [School of Medicine, Ewha Womans University, Mokdong Hospital, Seoul (Korea, Republic of)

    2012-11-15

    To evaluate the diagnostic accuracy and inter-observer agreement of magnetic resonance (MR) arthrography in the detection of labral lesions by location and to describe useful MR imaging findings of labral tears. Sixty-eight patients who underwent both pre-operative MR arthrography and arthroscopy were included. The location of the labrum was classified into anterior (2-6 o'clock), superior (12-2 o'clock), and posterior (6-12 o'clock). Sensitivity, specificity, accuracy, and inter-observer agreement of MR arthrography for the diagnosis of labral lesions by location were calculated. Frequency of MR imaging findings such as detachment, high signal intensity cleft, contour change, absence, and signal change of the labrum by location were analyzed. 35 anterior, 44 superior and 15 posterior labral lesions were detected by arthroscopy. The corresponding sensitivities were 91.4%, 79.5%, and 40.0%, specificities were 90.9%, 20.8%, and 86.8%, accuracies were 91.2%, 58.8%, and 76.5%, and kappa values were 0.823, 0.252, and 0.394, for anterior, superior, posterior lesions, respectively. The most common MR imaging findings were detachment in 60.0% of anterior labrums, high signal intensity cleft in 52.3% of superior labrums, and normal in 60.0% of posterior labrums. Diagnostic accuracy and inter-observer agreement of MR arthrography in the diagnosis of labral lesions are high in anterior labrums and low in superior or posterior labrums. The useful MR imaging findings of labral tears were different according to labral location.

  3. Effects of iodinated contrast agent, xylocaine and gadolinium concentration on the signal emitted in magnetic resonance arthrography: a samples study

    Directory of Open Access Journals (Sweden)

    Yvana Lopes Pinheiro da Silva

    2015-04-01

    Full Text Available Objective: To investigate the effects of dilution of paramagnetic contrast agent with iodinated contrast and xylocaine on the signal intensity during magnetic resonance arthrography, and to improve the paramagnetic contrast agent concentration utilized in this imaging modality. Materials and Methods: Samples specially prepared for the study with three different concentrations of paramagnetic contrast agent diluted in saline, iodinated contrast agent and xylocaine were imaged with fast spin echo T1-weighted sequences with fat saturation. The samples were placed into flasks and graphical analysis of the signal intensity was performed as a function of the paramagnetic contrast concentration. Results: As compared with samples of equal concentrations diluted only with saline, the authors have observed an average signal intensity decrease of 20.67% for iodinated contrast agent, and of 28.34% for xylocaine. However, the increased gadolinium concentration in the samples caused decrease in signal intensity with all the dilutions. Conclusion: Minimizing the use of iodinated contrast media and xylocaine and/or the use of a gadolinium concentration of 2.5 mmol/L diluted in saline will improve the sensitivity of magnetic resonance arthrography.

  4. A comparison of MRI and wrist arthrography in the diagnosis of TFC injury

    Energy Technology Data Exchange (ETDEWEB)

    Shionoya, Kaori; Nakamura, Ryogo; Imaeda, Toshihiko [Nagoya Univ., Aichi (Japan). Branch Hospital; Tsunoda, Kenji; Makino, Naoki

    1995-08-01

    The present study compared the diagnostic usefulness of magnetic resonance imaging (MRI) and wrist arthrography in triangular fibrocartilage (TFC) injuries. The subjects were 102 wrists with arthroscopically confirmed presence or absence of TFC perforation. TFC perforation was present in 35 and 47 wrists and absent in the other 67 and 55 wrists on arthrography and MRI, respectively. Using arthroscopy as the reference standard, arthrography for the detection of TFC perforation had a sensitivity of 85% and a specificity of 100%. All 6 false negative cases on arthrography had scarring adhesions of the TFC in the wrist. On the other hand, the sensitivity and specificity of MRI were 73% and 72%, respectively. An accuracy was 94% for arthrography and 73% for MRI. It was difficult to detect qualitative TFC injury and the presence or absence of TFC perforation on MRI. Arthrography is thus superior to MRI in both sensitivity and specificity. The complementary use of arthrography and MRI is considered to increase the diagnostic accuracy. (S.Y.).

  5. Detection of partial-thickness supraspinatus tendon tears: is a single direct MR arthrography series in ABER position as accurate as conventional MR arthrography?

    International Nuclear Information System (INIS)

    Schreinemachers, Saskia A.; Hulst, Victor P.M. van der; Woude, Henk-Jan van der; Willems, W.J.; Bipat, Shandra

    2009-01-01

    The purpose of this study was to retrospectively evaluate sensitivity and specificity of a single magnetic resonance (MR) arthrography series in abduction external rotation (ABER) position compared with conventional MR arthrography for detection of supraspinatus tendon tears, with arthroscopy as gold standard, and to assess interobserver variability. Institutional review board approval was obtained; informed consent was waived. MR arthrograms of 250 patients (170 men and 80 women; mean age, 36 years) were retrospectively and independently evaluated by three observers. Oblique coronal T1-weighted fat-suppressed images, proton density, and T2-weighted images and axial T1-weighted images and oblique sagittal T1-weighted fat-suppressed images were analyzed to detect supraspinatus tendon tears. Separately, a single T1-weighted fat-suppressed oblique axial series in ABER position was evaluated. Both protocols were scored randomly without knowledge of patients' clinical history and arthroscopy results. Tears were subclassified, based on articular surface integrity and extension (Lee classification). Interobserver agreement was assessed by kappa statistics for all patients. Ninety-two of 250 patients underwent arthroscopy; sensitivity and specificity of ABER and conventional MR arthrography were calculated and compared using paired McNemar test. Weighted kappa values of ABER and conventional MR arthrography were 0.48-0.65 and 0.60-0.67, respectively. According to arthroscopy, 69 of 92 patients had an intact cuff, and 23 patients had a cuff tear (16 partial thickness and seven full thickness). There were no statistically significant differences between ABER and conventional MR arthrography regarding sensitivity (48-61% and 52-70%, respectively) and specificity (80-94% and 91-95%). Sensitivity and specificity of a single T1-weighted series in ABER position and conventional MR arthrography are comparable for assessment of rotator cuff tears. (orig.)

  6. Detection of partial-thickness supraspinatus tendon tears: is a single direct MR arthrography series in ABER position as accurate as conventional MR arthrography?

    Energy Technology Data Exchange (ETDEWEB)

    Schreinemachers, Saskia A. [Onze Lieve Vrouwe Gasthuis, Department of Radiology, Amsterdam (Netherlands); Onze Lieve Vrouwe Gasthuis, Amsterdam (Netherlands); Hulst, Victor P.M. van der; Woude, Henk-Jan van der [Onze Lieve Vrouwe Gasthuis, Department of Radiology, Amsterdam (Netherlands); Willems, W.J. [Onze Lieve Vrouwe Gasthuis, Orthopaedic Surgery, Amsterdam (Netherlands); Bipat, Shandra [University of Amsterdam (NL). Department of Radiology, Academic Medical Center (Netherlands)

    2009-10-15

    The purpose of this study was to retrospectively evaluate sensitivity and specificity of a single magnetic resonance (MR) arthrography series in abduction external rotation (ABER) position compared with conventional MR arthrography for detection of supraspinatus tendon tears, with arthroscopy as gold standard, and to assess interobserver variability. Institutional review board approval was obtained; informed consent was waived. MR arthrograms of 250 patients (170 men and 80 women; mean age, 36 years) were retrospectively and independently evaluated by three observers. Oblique coronal T1-weighted fat-suppressed images, proton density, and T2-weighted images and axial T1-weighted images and oblique sagittal T1-weighted fat-suppressed images were analyzed to detect supraspinatus tendon tears. Separately, a single T1-weighted fat-suppressed oblique axial series in ABER position was evaluated. Both protocols were scored randomly without knowledge of patients' clinical history and arthroscopy results. Tears were subclassified, based on articular surface integrity and extension (Lee classification). Interobserver agreement was assessed by kappa statistics for all patients. Ninety-two of 250 patients underwent arthroscopy; sensitivity and specificity of ABER and conventional MR arthrography were calculated and compared using paired McNemar test. Weighted kappa values of ABER and conventional MR arthrography were 0.48-0.65 and 0.60-0.67, respectively. According to arthroscopy, 69 of 92 patients had an intact cuff, and 23 patients had a cuff tear (16 partial thickness and seven full thickness). There were no statistically significant differences between ABER and conventional MR arthrography regarding sensitivity (48-61% and 52-70%, respectively) and specificity (80-94% and 91-95%). Sensitivity and specificity of a single T1-weighted series in ABER position and conventional MR arthrography are comparable for assessment of rotator cuff tears. (orig.)

  7. Ultrasound versus Magnetic Resonance Arthrography in Acetabular Labral Tear Diagnostics: A Prospective Comparison in 20 Dysplastic Hips

    Energy Technology Data Exchange (ETDEWEB)

    Troelsen, A.; Jacobsen, S.; Bolvig, L.; Gelineck, J.; Roemer, L.; Soeballe, K. [Orthopedic Research Unit and Dept. of Radiology, Univ. Hospital of Aarhus, A arhus (Denmark)

    2007-11-15

    Background: Acetabular labral tears are highly associated with hip dysplasia. Magnetic resonance arthrography (MR arthrography) is the expensive and time-consuming contemporary gold-standard method in the radiological assessment of acetabular labral tears. Purpose: To assess the diagnostic ability of noninvasive ultrasound (US) examination compared to MR arthrography in diagnosing acetabular labral tears in dysplastic hip joints. Material and Methods: The study compared US examination and MR arthrography diagnosis of labral tears in 20 consecutively referred dysplastic hip joints. Results: The ability to diagnose acetabular labral tears upon US examination was calculated: sensitivity 44%, specificity 75%, positive predictive value 88%, and negative predictive value 25%. Conclusion: The ability of US examination in diagnosing acetabular labral tears is not yet good enough. The technique is still to be developed, and more experience, especially with the interpretation of US examinations, is needed.

  8. MR arthrography of the knee

    International Nuclear Information System (INIS)

    Kramer, J.; Engel, A. Jr.; Stiglbauer, R. Jr.; Prayer, L. Jr.; Hajek, P. Jr.; Imhof, H.

    1991-01-01

    This paper demonstrates the diagnostic value of MR arthrography in the assessment of cartilaginous lesions, including osteochondritis dissecans. One hundred thirty-two knees of 125 patients were examined with MR arthrography performed on a 1.5-T magnet with a knee resonator. T1-weighted spin-echo and T2*-weighted three-dimensional gradient-echo sequences were obtained after intraarticular administration of 40 mL of 2-mmol GD-DTPA solution. Seventy-five patients were also imaged without contrast agent. The description of the articular surface was classified into four types: I, normal cartilage surface and thickness; II, surface normal or slightly irregular; III, severe surface irregularities and cartilage defects; and IV, extensive cartilage defects, scar formation. MR findings were correlated with those of arthroscopy/arthrotomy (n = 75)

  9. Feasibility and preliminary results of SPECT/CT arthrography of the wrist in comparison with MR arthrography in patients with suspected ulnocarpal impaction

    Energy Technology Data Exchange (ETDEWEB)

    Strobel, Klaus [Lucerne Cantonal Hospital, Department of Nuclear Medicine and Radiology, Lucerne (Switzerland); Kantonsspital Luzern, Roentgeninstitut/Nuklearmedizin, Luzern (Switzerland); Steurer-Dober, Isabelle; Huellner, Martin W.; Sol Perez Lago, Maria del; Veit-Haibach, Patrick; Tornquist, Katharina [Lucerne Cantonal Hospital, Department of Nuclear Medicine and Radiology, Lucerne (Switzerland); Silva, Angela J. da [Advanced Molecular Imaging, Philips Healthcare, San Jose, CA (United States); Bodmer, Elvira; Wartburg, Urs von; Hug, Urs [Lucerne Cantonal Hospital, Division of Hand and Plastic Surgery, Lucerne (Switzerland)

    2014-03-15

    To evaluate the feasibility and performance of SPECT/CT arthrography of the wrist in comparison with MR arthrography in patients with suspected ulnocarpal impaction. This prospective study included 28 wrists of 27 patients evaluated with SPECT/CT arthrography and MR arthrography. Iodine contrast medium and gadolinium were injected into the distal radioulnar and midcarpal joints. Late-phase SPECT/CT was performed 3.5 h after intravenous injection of approximately 650 MBq {sup 99m}Tc-DPD. MR and SPECT/CT images were separately reviewed in relation to bone marrow oedema, radionuclide uptake, and tears in the scapholunate (SL) and lunotriquetral (LT) ligaments and triangular fibrocartilage complex (TFCC), and an overall diagnosis of ulnar impaction. MR, CT and SPECT/CT imaging findings were compared with each other, with the surgical findings in 12 patients and with clinical follow-up. The quality of MR arthrography and SPECT/CT arthrography images was fully diagnostic in 23 of 28 wrists (82 %) and 25 of 28 wrists (89 %), respectively. SPECT/CT arthrography was not diagnostic for ligament lesions due to insufficient intraarticular contrast in one wrist. MR and SPECT/CT images showed concordant findings regarding TFCC lesions in 22 of 27 wrists (81 %), SL ligament in 22 of 27 wrists (81 %) and LT ligament in 23 of 27 wrists (85 %). Bone marrow oedema on MR images and scintigraphic uptake were concordant in 21 of 28 wrists (75 %). MR images showed partial TFCC defects in four patients with normal SPECT/CT images. MR images showed bone marrow oedema in 4 of 28 wrists (14 %) without scintigraphic uptake, and scintigraphic uptake was present without MR bone marrow oedema in three wrists (11 %). Regarding diagnosis of ulnar impaction the concordance rate between CT and SPECT/CT was 100 % and reached 96 % (27 of 28) between MR and SPECT/CT arthrography. The sensitivity and specificity of MR, CT and SPECT/CT arthrography were 93 %, 100 % and 100 %, and 93 %, 93 % and 93

  10. Arthrography

    Medline Plus

    Full Text Available ... medical imaging to evaluate conditions of joints. It can either be direct or indirect. Indirect arthrography is ... virtually all other internal body structures. The images can then be examined on a computer monitor connected ...

  11. Arthrography

    Medline Plus

    Full Text Available ... and possibly hear gurgling when the joint is moved. If your arthrography exam involves MR imaging: It is normal for the area of your body being imaged to feel slightly warm, but if it ...

  12. Magnetic resonance arthrography including ABER view in diagnosing partial-thickness tears of the rotator cuff: Accuracy, and inter- and intra-observer agreements

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Joon-Yong; Jee, Won-Hee; Chun, Ho Jong; Ahn, Myeong Im (Dept. of Radiology, Seoul St. Mary' s Hospital, School of Medicine, Catholic Univ. of Korea, Seoul (Korea)), e-mail: whjee@catholic.ac.kr; Kim, Yang-Soo (Dept. of Orthopedic Surgery, Seoul St. Mary' s Hospital, School of Medicine, Catholic Univ. of Korea, Seoul (Korea))

    2010-03-15

    Background: Partial-thickness tear of the rotator cuff is a common cause of shoulder pain. Magnetic resonance (MR) arthrography has been described as a useful measure to diagnose rotator cuff abnormalities. Purpose: To determine the reliability and accuracy of MR arthrography with abduction and external rotation (ABER) view for the diagnosis of partial-thickness tears of the rotator cuff. Material and Methods: Among patients who underwent MR arthrographies, 22 patients (12 men, 10 women; mean age 45 years) who had either partial-thickness tear or normal tendon on arthroscopy were included. MR images were independently scored by two observers for partial-thickness tears of the rotator cuff. Interobserver and intraobserver agreements for detection of partial-thickness tears of the rotator cuff were calculated by using kappa coefficients. The differences in areas under the receiver operating characteristic (ROC) curves were assessed with a univariate Z-score test. Differences in sensitivity and specificity for interpretations based on different imaging series were tested for significance using the McNemar statistic. Results: Sensitivity, specificity, and accuracy of each reader on MR imaging without ABER view were 83%, 90%, and 86%, and 83%, 80%, and 82%, respectively, whereas on overall interpretation including ABER view, the sensitivity, specificity, and accuracy of each reader were 92%, 70%, and 82%, and 92%, 80%, and 86%, respectively. Including ABER view, interobserver agreement for partial-thickness tear increased from kappa=0.55 to kappa=0.68. Likewise, intraobserver agreements increased from kappa=0.79 and 0.53 to kappa=0.81 and 0.70 for each reader, respectively. The areas under the ROC curves for each reader were 0.96 and 0.90, which were not significantly different. Conclusion: Including ABER view in routine sequences of MR arthrography increases the sensitivity, and inter- and intraobserver agreements for detecting partial-thickness tear of rotator cuff

  13. Magnetic resonance arthrography including ABER view in diagnosing partial-thickness tears of the rotator cuff: Accuracy, and inter- and intra-observer agreements

    International Nuclear Information System (INIS)

    Jung, Joon-Yong; Jee, Won-Hee; Chun, Ho Jong; Ahn, Myeong Im; Kim, Yang-Soo

    2010-01-01

    Background: Partial-thickness tear of the rotator cuff is a common cause of shoulder pain. Magnetic resonance (MR) arthrography has been described as a useful measure to diagnose rotator cuff abnormalities. Purpose: To determine the reliability and accuracy of MR arthrography with abduction and external rotation (ABER) view for the diagnosis of partial-thickness tears of the rotator cuff. Material and Methods: Among patients who underwent MR arthrographies, 22 patients (12 men, 10 women; mean age 45 years) who had either partial-thickness tear or normal tendon on arthroscopy were included. MR images were independently scored by two observers for partial-thickness tears of the rotator cuff. Interobserver and intraobserver agreements for detection of partial-thickness tears of the rotator cuff were calculated by using κ coefficients. The differences in areas under the receiver operating characteristic (ROC) curves were assessed with a univariate Z-score test. Differences in sensitivity and specificity for interpretations based on different imaging series were tested for significance using the McNemar statistic. Results: Sensitivity, specificity, and accuracy of each reader on MR imaging without ABER view were 83%, 90%, and 86%, and 83%, 80%, and 82%, respectively, whereas on overall interpretation including ABER view, the sensitivity, specificity, and accuracy of each reader were 92%, 70%, and 82%, and 92%, 80%, and 86%, respectively. Including ABER view, interobserver agreement for partial-thickness tear increased from κ=0.55 to κ=0.68. Likewise, intraobserver agreements increased from κ=0.79 and 0.53 to κ=0.81 and 0.70 for each reader, respectively. The areas under the ROC curves for each reader were 0.96 and 0.90, which were not significantly different. Conclusion: Including ABER view in routine sequences of MR arthrography increases the sensitivity, and inter- and intraobserver agreements for detecting partial-thickness tear of rotator cuff tendon

  14. Magnetic resonance arthrography in chronic wrist pain

    International Nuclear Information System (INIS)

    Valeri, G.; Ferrara, C.; Carloni, S.

    1999-01-01

    The purpose of this paper is to investigate the clinical role of Magnetic Resonance Arthrography (MRA) of the wrist in subjects with chronic pain. Thirty-five patients complaining of wrist pain for more than 6 months were submitted to MRI an MRA. All patients received and intra-articular injection of 2-10 mL of a 10 mmol saline solution of Gd-DPTA. The overall diagnostic accuracy rates of MRI and MRA were 40% and 81% respectively, with sensitivity and specificity of 63% and 39% (MRI) and of 82% and 79% (MRA). The conclusion is that compared with MRI, MRA can be considered a useful tool for the visualization of interosseus carpal ligaments and of the triangular fibrocartilage complex. MRA also helps detect injuries in these structures [it

  15. The role of pubic symphyseal CT arthrography in the imaging of athletic pubalgia.

    Science.gov (United States)

    McArthur, Tatum A; Narducci, Carl A; Lopez-Ben, Robert R

    2014-11-01

    The purpose of this article is to describe the results of pubic symphyseal CT arthrography compared with MRI in patients with suspected athletic pubalgia. In this study, two musculoskeletal radiologists retrospectively searched our department's PACS to identify patients who had undergone CT-guided injection with concurrent pubic symphyseal CT arthrography for evaluation and treatment of groin pain, sports hernia, or athletic pubalgia over a 5.5-year period (January 1, 2007-July 1, 2012). The MR and CT arthrography images and reports, clinical findings at presentation, pain response to injection, and operative findings were reviewed using the electronic medical record. Twelve patients underwent CT-guided injection and pubic symphyseal CT arthrography at our institution during the 5.5-year study period. Nine of the 12 patients had undergone MRI before the procedure. In two of the three patients who had not undergone MRI, CT arthrography revealed secondary clefts. Three of four patients who had secondary clefts on MRI had contrast extravasation reproducing the cleft at CT. Three patients had MRI findings suggestive of athletic pubalgia without MRI evidence of a secondary cleft; in all three of these patients, CT arthrography showed a secondary cleft. In four patients, CT arthrography revealed tendon tears at the adductor origin that were not apparent on MRI. All 12 patients reported decreased groin pain after injection. Pubic symphyseal CT arthrography is a useful technique for the diagnosis and short-term pain relief of athletic pubalgia. It can be used to identify secondary clefts and to detect tendon tears that can potentially be overlooked on MRI.

  16. Arthrography

    Medline Plus

    Full Text Available ... the joint and appears on the MR images. As in conventional direct arthrography, the contrast material outlines the structures within the joint, such as cartilage, ligaments and bones, and allows them to ...

  17. Shoulder Magnetic Resonance Arthrography: A Prospective Randomized Study of Anterior and Posterior Ultrasonography-Guided Contrast Injections

    Energy Technology Data Exchange (ETDEWEB)

    Koivikko, M.P.; Mustonen, A.O.T. (Dept. of Radiology, Helsinki Univ. Central Hospital, Helsinki (Finland))

    2008-10-15

    Background: Magnetic resonance (MR) arthrography is an accurate imaging method for internal shoulder derangements and rotator cuff pathologies. Both anterior and posterior contrast injection techniques, under palpatory, fluoroscopic, or ultrasonographic guidance have been described in the literature. However, clinical comparisons of the injection techniques remain few. Purpose: To compare the performance of anterior and posterior ultrasonography (US)-guided arthrography injections of the shoulder regarding patient discomfort and influence on diagnostic MR reading, and to illustrate the typical artifacts resulting from contrast leakage in the respective techniques. Material and Methods: 43 MR arthrographies were prospectively randomized into anterior and posterior US-guided contrast injections and performed by two radiologists, with the study of artifacts from contrast leakage. Pain from the injections was assessed by a survey utilizing a 100-mm visual analogue scale (VAS). Results: Of the 23 anterior injections, nine caused contrast artifacts in the subscapular tendon, and in three the leakage extended further anteriorly. Of the 20 posterior injections, 12 showed injection artifacts of the rotator cuff, extending outside the cuff in seven. Two of the anterior and none of the posterior artifacts compromised diagnostic quality. In posterior injections, the leakage regularly occurred at the caudal edge of the infraspinatus muscle and was easily distinguishable from rotator cuff tears. All patients completed the pain survey. Mean VAS scores were 25.0 (median 18, SD 22) for anterior, and 25.4 (median 16, SD 25) for posterior injections. The two radiologists achieved different mean VAS scores but closely agreed as to anterior and posterior VAS scores. Conclusion: Arthrography injections were fairly simple to perform under US guidance. Patient discomfort for anterior and posterior injections was equally minor. A tailored approach utilizing anterior or posterior injections

  18. Arthrography

    Medline Plus

    Full Text Available ... The images can then be examined on a computer monitor connected to an image archive (PACS system) or printed or copied to CD. MRI does not use ionizing radiation (x-rays). CT direct arthrography uses the same type of ... by a computer using x-rays. top of page What are ...

  19. Arthrography

    Medline Plus

    Full Text Available ... conventional direct arthrography and may be supplemented by air to produce a double contrast CT arthrogram. CT ... tissue shows up in shades of gray and air appears black. Until recently, x-ray images were ...

  20. Arthrography

    Medline Plus

    Full Text Available ... a table on which the patient lies. The traditional MRI unit is a large cylinder-shaped tube ... MRI) - Shoulder X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Direct Arthrography Videos ...

  1. Arthrography

    Medline Plus

    Full Text Available ... thus allowing for enhanced imaging of small internal structures. This leads to improved evaluation of diseases or ... conventional direct arthrography, the contrast material outlines the structures within the joint, such as cartilage, ligaments and ...

  2. Comparison between 3D isotropic and 2D conventional MR arthrography for diagnosing rotator cuff tear and labral lesions: A meta-analysis.

    Science.gov (United States)

    Lee, Sun Hwa; Yun, Seong Jong; Jin, Wook; Park, So Young; Park, Ji Seon; Ryu, Kyung Nam

    2018-03-30

    lesions. 3D-isotropic MR arthrography can replace 2D-conventional MR arthrography. 3D-isotropic MR arthrography using TSE sequence is recommended for more accurate diagnosis, as it demonstrates increased sensitivity. 2 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.

  3. MR arthrography of the ankle joint

    International Nuclear Information System (INIS)

    Trattnig, S.; Rand, T.; Breitenseher, M.; Ba-Ssalamah, A.; Schick, S.; Imhof, H.

    1999-01-01

    Due to its superior soft tissue contrast conventional MRI is the imaging method of choice in the evaluation of ankle joint disorders. Conventional MR imaging can accurately demonstrate normal or acutely injured ligaments; however, in subacute and chronic injury joint fluid necessary for delineation of injured ligaments is absent and MR arthrography should be performed. MR arthrography uses the intraarticular injection of contrast material to distend the joint, yielding improved discrimination of intraarticular structures. This joint distension with MR arthrography is also helpful in the staging of osteochondritis dissecans, since in cases of unstable lesions tracking of contrast material into the interface can be more easily demonstrated. Finally, high contrast and joint distension by MR arthrography improves the detection of intraarticular loose bodies, which often require surgery. MR artrography, although invasive, may provide additional information in various ankle joint disorders. (orig.) [de

  4. MR arthrography of the shoulder: possible indications for clinical use; Einsatzmoeglichkeiten der MR-Arthrographie bei Erkrankungen des Schultergelenkes

    Energy Technology Data Exchange (ETDEWEB)

    Kreitner, K.F. [Mainz Univ. (Germany). Klinik mit Poliklinik fuer Radiologie; Grebe, P. [Mainz Univ. (Germany). Klinik mit Poliklinik fuer Radiologie; Kersjes, W. [Mainz Univ. (Germany). Klinik mit Poliklinik fuer Radiologie; Runkel, M. [Mainz Univ. (Germany). Klinik fuer Unfallchirurgie; Kirschner, P. [Elisabeth-Hospital, Mainz (Germany). Abt. fuer Unfall- und Wiederherstellungschirurgie St. Vincenz; Schild, H.H. [Mainz Univ. (Germany). Klinik mit Poliklinik fuer Radiologie

    1994-02-01

    In a prospective study possible indications for MR arthrography of the shoulder were evaluated. 37 patients were examined before and after intraarticular administration of a 2-mmolar solution of Gd-DTPA. MR arthrography was performed if there was no joint effusion and/or an uncertain finding concerning the rotator cuff or the capsulolabral complex on plain MR images. MR arthrography leads to a better demonstration of labrum pathology in 11/22 patients and to a superior delineation of the capsuloligamentous apparatus in 20/22 cases. In 9/15 patients with impingement lesions MR arthrography allowed a differentiation of severe tendinitis from partial and small full-thickness tears of the rotator cuff. MR arthrography of the shoulder joint enhances the accuracy of MR in case of an uncertain finding on plain MR images. (orig.) [Deutsch] In einer prospektiven Studie sollten Einsatzmoeglichkeiten der MR-Arthrographie bei Erkrankungen des Schultergelenkes herausgearbeitet werden. 37 Patienten wurden sowohl nativ als auch nach intraartikulaerer Gabe einer 2mmolaren Gd-DTPA-Loesung untersucht. Voraussetzungen fuer die KM-Gabe waren ein fehlender Gelenkerguss und/oder ein unklarer Befund des Labrum-Kapsel-Komplexes oder der Rotatorenmanschette in der Nativuntersuchung. Durch die MR-Arthrographie wurde bei 11/22 Patienten eine verbesserte Darstellung der Labrumpathologie erzielt; in 20/22 Faellen ergabe sich eine zuverlaessige Beurteilung der Gelenkkapsel. Bei 9/15 Patienten mit Erkrankungen der Rotatorenmanschette konnten Tendinitiden von partiellen und kleinen kompletten Rotatorenmanschettenrupturen sicher differenziert werden. Die MR-Arthrographie des Schultergelenkes fuehrt bei nicht eindeutigen Befunden in der Nativuntersuchung zu einer verbesserten Treffsicherheit der MR-Diagnostik. (orig.)

  5. Arthrography

    Medline Plus

    Full Text Available ... have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures that those parts of a patient's body not being imaged receive minimal radiation exposure. top of page What are the limitations of arthrography? The limitations of ...

  6. Multidetector spiral CT arthrography of the shoulder

    Energy Technology Data Exchange (ETDEWEB)

    Lecouvet, Frederic E. [Departments of Radiology and Orthopaedic Surgery, Cliniques Universitaires Saint-Luc, Universite Catholique de Louvain, Hippocrate Avenue 10/2942, 1200 Brussels (Belgium)], E-mail: frederic.lecouvet@uclouvain.be; Simoni, Paolo; Koutaissoff, Sophie; Vande Berg, Bruno C.; Malghem, Jacques; Dubuc, Jean-Emile [Departments of Radiology and Orthopaedic Surgery, Cliniques Universitaires Saint-Luc, Universite Catholique de Louvain, Hippocrate Avenue 10/2942, 1200 Brussels (Belgium)

    2008-10-15

    Although MR imaging and MR arthrography are the first choice modalities for shoulder imaging, CT arthrography (CTA) may be used successfully to address many clinical questions. The advent of submillimeter multiple detector CT technology and subsequent excellent three-plane resolution has considerably increased the quality of CTA examinations and has propelled this technique to the forefront in a growing number of indications. The combined use of iodinated contrast material for fluoroscopic confirmation of the articular position of the needle before injection of gadolinium chelates for MR arthrography offers the unique opportunity to compare CTA and MRA findings in carefully selected cases. This paper illustrates capabilities and limits of CTA for the study of rotator cuff tears, shoulder instability, cartilage lesions, anatomical variants and abnormalities of the glenoid labrum, with correlations to MR arthrography and surgical findings.

  7. Multidetector spiral CT arthrography of the shoulder

    International Nuclear Information System (INIS)

    Lecouvet, Frederic E.; Simoni, Paolo; Koutaissoff, Sophie; Vande Berg, Bruno C.; Malghem, Jacques; Dubuc, Jean-Emile

    2008-01-01

    Although MR imaging and MR arthrography are the first choice modalities for shoulder imaging, CT arthrography (CTA) may be used successfully to address many clinical questions. The advent of submillimeter multiple detector CT technology and subsequent excellent three-plane resolution has considerably increased the quality of CTA examinations and has propelled this technique to the forefront in a growing number of indications. The combined use of iodinated contrast material for fluoroscopic confirmation of the articular position of the needle before injection of gadolinium chelates for MR arthrography offers the unique opportunity to compare CTA and MRA findings in carefully selected cases. This paper illustrates capabilities and limits of CTA for the study of rotator cuff tears, shoulder instability, cartilage lesions, anatomical variants and abnormalities of the glenoid labrum, with correlations to MR arthrography and surgical findings

  8. MR-imaging of anterior tibiotalar impingement syndrome: Agreement, sensitivity and specificity of MR-imaging and indirect MR-arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Haller, Joerg [Department of Radiology, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Ludwig Boltzmann Institute for Osteology, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Bernt, Reinhard [Department of Radiology, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria)]. E-mail: reinhard.bernt@wgkk.sozvers.at; Seeger, Thomas [Department of Trauma Surgery, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Weissenbaeck, Alexander [Department of Trauma Surgery, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Tuechler, Heinrich [Ludwig Boltzmann Institute for Hematology, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Resnick, Donald [Department of Radiology, VA Medical Center, UCSD, 3350 La Jolla Village Dr, San Diego, CA 92161 (United States)

    2006-06-15

    Objective: To clarify the role of MR-imaging in the diagnosis of anterior ankle impingement syndromes. Materials and methods: We prospectively examined 51 consecutive patients with chronic ankle pain by MR-imaging. Arthroscopy was performed in 29 patients who previously underwent non-enhanced MR-imaging; in 11 patients, indirect MR-arthrography additionally was performed. MR-examinations were correlated with clinical findings; MR and arthroscopy scores were statistically compared, agreement was measured. Results: Arthroscopy demonstrated granulation tissue in the lateral gutter (38%) and anterior recess (31%), lesions of the anterior tibiofibular (31%) and the anterior talofibular ligament (21%) as well as intraarticular bodies (10%). Stenosing tenosynovitis and a ganglionic cyst were revealed as extraarticular causes for chronic ankle pain by MR-examination (17%). Agreement of MR-imaging and arthroscopy was fair for the anterior talofibular ligament and the anterior joint cavity (kappa 0.40). Major discrepancy was found for non-enhanced MR scans (kappa 0.49) when compared with indirect MR-arthrography (kappa 0.03) in the anterior cavity. The sensitivity for lesions of the anterior talofibular and calcaneofibular ligament and the anterior cavity (0.91-0.87) detected by MR-imaging was superior in comparison to lesions of the anterior tibiofibular ligament and anteromedial cavity (0.50-0.24). Conclusion: MR-imaging provides additional information about the mechanics of chronic ankle impingement rather than an accurate diagnosis of this clinical entity. The method is helpful in differentiating extra- from intra-articular causes of ankle impingement. Indirect MR-arthrography has little or no additional value in patients with ankle impingement syndrome.

  9. MR-imaging of anterior tibiotalar impingement syndrome: Agreement, sensitivity and specificity of MR-imaging and indirect MR-arthrography

    International Nuclear Information System (INIS)

    Haller, Joerg; Bernt, Reinhard; Seeger, Thomas; Weissenbaeck, Alexander; Tuechler, Heinrich; Resnick, Donald

    2006-01-01

    Objective: To clarify the role of MR-imaging in the diagnosis of anterior ankle impingement syndromes. Materials and methods: We prospectively examined 51 consecutive patients with chronic ankle pain by MR-imaging. Arthroscopy was performed in 29 patients who previously underwent non-enhanced MR-imaging; in 11 patients, indirect MR-arthrography additionally was performed. MR-examinations were correlated with clinical findings; MR and arthroscopy scores were statistically compared, agreement was measured. Results: Arthroscopy demonstrated granulation tissue in the lateral gutter (38%) and anterior recess (31%), lesions of the anterior tibiofibular (31%) and the anterior talofibular ligament (21%) as well as intraarticular bodies (10%). Stenosing tenosynovitis and a ganglionic cyst were revealed as extraarticular causes for chronic ankle pain by MR-examination (17%). Agreement of MR-imaging and arthroscopy was fair for the anterior talofibular ligament and the anterior joint cavity (kappa 0.40). Major discrepancy was found for non-enhanced MR scans (kappa 0.49) when compared with indirect MR-arthrography (kappa 0.03) in the anterior cavity. The sensitivity for lesions of the anterior talofibular and calcaneofibular ligament and the anterior cavity (0.91-0.87) detected by MR-imaging was superior in comparison to lesions of the anterior tibiofibular ligament and anteromedial cavity (0.50-0.24). Conclusion: MR-imaging provides additional information about the mechanics of chronic ankle impingement rather than an accurate diagnosis of this clinical entity. The method is helpful in differentiating extra- from intra-articular causes of ankle impingement. Indirect MR-arthrography has little or no additional value in patients with ankle impingement syndrome

  10. Arthrography

    Medline Plus

    Full Text Available ... processes the imaging information is located in a separate room from the scanner. Other equipment necessary for performing arthrography include a variety of needles, syringes and a water-soluble contrast material. top of page How does the procedure work? X-rays are a form of radiation like ...

  11. The preliminary application of magnetic resonance arthrography in the diagnosis of acetabular labrale tears

    International Nuclear Information System (INIS)

    Hong Wen; Zhang Xuezhe; Wang Wu; Yue Debo; Wang Weiguo

    2010-01-01

    Objective: To investigate the application value of MR arthrography (MRA) in the diagnosis of acetabular lab ral tears. Methods: Fifteen patients with a high degree of suspected acetabular lab ral tears received fluoroscope-guided injection of the contrast media into the hip joint (hip arthrography) and fat-saturated spin-echo T 1 -weighted images were obtained in the coronal, sagittal, oblique-axial and radial planes. Hip arthroscopy was performed on 12 of them. Results: Lab ral tears which were diagnosed in 11 patients by hip MRA were confirmed at hip arthroscopy. One patient showed no MRA indication of lab ral tear, also showed normal on arthroscopy. Tear in the anterior-superior quadrant 10 cases of 12 joints (12/13), posterior-superior quadrant 1 case of a joint (1/13). In 11 patients who underwent arthroscopy, hip MRA diagnosed 3 (3/13) joints labrale tears in coronal planes, 10 (10/13) joints in sagittal planes and 13 (13/13) labrale tears in axial-oblique and radial planes. In 15 patients with 20 hip joints, 5 cases 6 joints (6/20) with normal acetabular sublabral sulcus were performed. Conclusions: MR arthrography of hip is a reliable method in the diagnosis of acetabular labrale tears. Scanning method should be included fat-saturated spin-echo T 1 -weighted images in sagittal and oblique-axial planes or sagittal plus radial planes. The diagnosis of torn posterior-inferior quadrant should pay attention to the existence of a normal variation. (authors)

  12. Indirect MR arthrography of the shoulder in detection of rotator cuff ruptures

    International Nuclear Information System (INIS)

    Yagci, B.; Manisali, M.; Yilmaz, E.; Oezaksoy, D.; Kovanlikaya, I.; Oezkan, M.; Ekin, A.

    2001-01-01

    The aim of this study was to compare the efficacy of indirect MR arthrography images obtained following intravenous contrast injection and conventional MR imaging in the diagnosis of rotator cuff tears. Twenty-four patients with clinically suspected rotator cuff disease were examined. Conventional MR images and post-contrast indirect MR arthrography images were obtained. All images were evaluated in a blinded fashion by two musculoskeletal radiologist. Results were than analyzed depending on surgical output. The correlation coefficient (Spearman rank correlation test) and the kappa values for agreement between surgery and imaging techniques were calculated. The correlation coefficients between indirect MR arthrography and surgery for reader 1 and reader 2 were 0.9137 and 0.9773, respectively. Whereas the agreement between conventional MR imaging and surgery was moderate (κ=0.383-0.571), the agreement between indirect MR arthrography and surgery was excellent (κ=0.873-0.936). We suggest the use of indirect MR arthrography technique when conventional MR images are equivocal in diagnosis of rotator cuff disease. (orig.)

  13. MR arthrography of the shoulder: possible indications for clinical use

    International Nuclear Information System (INIS)

    Kreitner, K.F.; Grebe, P.; Kersjes, W.; Runkel, M.; Kirschner, P.; Schild, H.H.

    1994-01-01

    In a prospective study possible indications for MR arthrography of the shoulder were evaluated. 37 patients were examined before and after intraarticular administration of a 2-mmolar solution of Gd-DTPA. MR arthrography was performed if there was no joint effusion and/or an uncertain finding concerning the rotator cuff or the capsulolabral complex on plain MR images. MR arthrography leads to a better demonstration of labrum pathology in 11/22 patients and to a superior delineation of the capsuloligamentous apparatus in 20/22 cases. In 9/15 patients with impingement lesions MR arthrography allowed a differentiation of severe tendinitis from partial and small full-thickness tears of the rotator cuff. MR arthrography of the shoulder joint enhances the accuracy of MR in case of an uncertain finding on plain MR images. (orig.) [de

  14. Fluoroscopically-Guided Posterior Approach for Shoulder Magnetic Resonance Arthrography: Comparison with Conventional Anterior Approach

    International Nuclear Information System (INIS)

    Yoo, Koun J.; Ha, Doo Hoe; Lee, Sang Min

    2011-01-01

    To prospectively evaluate the usefulness of the fluoroscopically-guided posterior approach compared with the anterior approach for shoulder magnetic resonance(MR) arthrography. Institutional review board approval and informed consent were obtained. Among 60 shoulder MR arthrographies performed on 59 patients with symptomatic shoulders, an intra-articular injection was performed (30 cases using the anterior approach and 30 using the posterior approach). Procedure-related pain was assessed by using a 5 score visual analogue scale (VAS). Depth of the puncture and standardized depth of puncture by body mass index (BMI) were recorded. The contrast leakage along the course of the puncture was evaluated by reviewing the MR. The statistical analyses included the Mann-Whitney U and Kruskal-Wallis test. There was no significant difference in VAS scores between the anterior and posterior groups (1.77 ± 1.10 vs. 1.80 ± 0.96). Depth of puncture and standardized depth of puncture by BMI were significantly shorter in the posterior group than those in the anterior group (4.4 ± 0.8 cm and 1.8 ± 0.3 cm vs. 6.6 ± 0.9 cm and 2.8 ± 0.4 cm, p < 0.001), respectively. The incidence of contrast leakage was more frequent in the posterior group (p = 0.003). The posterior approach will be useful in shoulder MR arthrography with a suspected anterior pathology, a postoperative follow-up study or obese patient.

  15. A study on usefulness of CT arthrography for the temporomandibular joint

    Energy Technology Data Exchange (ETDEWEB)

    Murakami, Shumei [Osaka Univ. (Japan). School of Dentistry

    1992-06-01

    In the field of orthopedics, CT arthrography has been utilized for the shoulder and the knee joints diagnosis. In this study, CT arthrography was applied to the temporomandibular joint (TMJ) and the usefulness of this method was evaluated experimentally and clinically. In the experimental study, CT, CT arthrography and arthrotomogtaphy were compared each other with serial section from human autopsy specimen. It was confirmed that arthrography was indispensable for diagnosis of the location and configuration of the articular disk. In the sagittal section, CT arthrography was almost equal to arthrotomography. But in the coronal section, CT arthrography proved to be advantageous to arthrotomography, because there were various blur images on the arthrotomographic images from the complex bony structures of the skull. In the clinical study, coronal CT arthrography was applied for the patients with internal derangements of the TMJ. The mesio-lateral displacement of the disk (62%), perforation of the attachment (23%), and the intra-articular adhesion (70%) could be diagnosed. BY CT arthrography, the mesio-lateral displacement of the disk was more clearly diagnosed and the intra-articular adhesions were proved with higher rate than by the arthrotomography. From this study, it was concluded that CT arthrography has an important role in diagnosis of the TMJ soft tissue. (author) 51 refs.

  16. Diagnostic performance of indirect MR arthrography for the diagnosis of rotator cuff tears at 3.0 T.

    Science.gov (United States)

    Lee, Ji Hyun; Yoon, Young Cheol; Jee, Sukkyung

    2015-06-01

    Indirect magnetic resonance (MR) arthrography is a non-invasive method for shoulder imaging. However, there are no studies that have examined the diagnostic performance of indirect MR arthrography for the diagnosis of rotator cuff tears in a large patient population. To assess the diagnostic performance of indirect fast spin-echo (FSE) MR arthrography for the diagnosis of rotator cuff tears at 3.0 T. A total of 149 patients who had undergone indirect shoulder MR arthrography followed by arthroscopic surgery were enrolled in this retrospective study. Two musculoskeletal radiologists evaluated images from each patient for the presence of supraspinatus-infraspinatus (SSP-ISP) or subscapularis (SSC) tendon tears. Using the arthroscopic findings as the reference standard, the overall diagnostic performance and detection rates for SSP-ISP and SSC tendon tears were calculated. The sensitivity, specificity, and accuracy of readers I and II for the diagnosis of SSP-ISP tendon tears were 94% and 95%, 89% and 85%, and 93% and 93%, respectively. The sensitivity of imaging for detection of SSP-ISP tendon tears by readers I and II were 100% and 100% for full-thickness tears and 84% and 86% for partial-thickness tears, respectively. The sensitivity, specificity, and accuracy of readers I and II for the diagnosis of SSC tendon tears were 80% and 76%, 89% and 93%, and 85% and 85%, respectively. Indirect MR arthrography is useful for the detection of SSP-ISP and SSC tendon tears. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  17. Diagnostic value of US, CT arthrography, and 0.5-T MR imaging of lesions of the biceps tendon

    International Nuclear Information System (INIS)

    Saez, F.; Elizagaray, E.; Pena, J.M.; Ferrero, A.; Azkuna, I.; Larrea, L.

    1990-01-01

    This paper evaluates the role of US, CT-arthrography, and MR imaging in lesions in the tendon of the long head of the biceps brachii and bicipital groove. One hundred fifty-four patients with painful shoulder were prospectively studied by means of US and axial CT-arthrography, and 45 of them were also examined with 0.5-T MR imaging. Fifty-three (34.4%) patients showed biceps tendon or bicipital groove abnormalities; including 34 bicipital groove bone spurs, 31 cases of tendinitis, eight intraarticular ruptures, four subluxations, and eight medial dislocations

  18. MR imaging of the shoulder

    International Nuclear Information System (INIS)

    Fritts, H.M.; Craig, E.; Kyle, R.; Strefling, M.; Miller, D.; Heithoff, K.; Schellhas, K.

    1988-01-01

    Magnetic resonance (MR) imaging (1.5-T unit) was performed in over 600 shoulders to evaluate shoulder pain. Ultrasound (US) and arthrography were performed in over 100 patients. Surgery was performed in over 75 patients. MR imaging offers information not well evaluated with other modalities, including bony impingement, tendinitis, bursitis, and osseous abnormalities, such as primary arthritis, avascular necrosis, occult fractures, and tumors. US and MR findings correlate well with surgical findings for medium to large rotator cuff tears. MR imaging with T2 weighting is superior for differentiating small tears from associated tendinitis. An algorithm for cost-effective shoulder imaging integrating US, MR imaging, arthrography, and computed tomographic arthrography are presented

  19. An overview of MR arthrography with emphasis on the current technique and applicational hints and tips

    International Nuclear Information System (INIS)

    Sahin, Guelden; Demirtas, Mehmet

    2006-01-01

    Magnetic resonance (MR) arthrography has been investigated in every major peripheral joint of the body, and has been proven to be effective in determining the integrity of intraarticular ligamentous and fibrocartilaginous structures and in the detection or assessment of osteochondral lesions and loose bodies in selected cases. Several methods could be used to create arthrogram effect during MR imaging, however, direct MR arthrography using diluted gadolinium as the contrast agent is the most commonly used technique and is the most reliable of all. MR arthrography is useful for demonstrating labrocapsular-ligamentous abnormalities and distinguishing partial thickness rotator cuff tears from focal full thickness tears in the shoulder, identifying or excluding recurrent tears following meniscal operations in the knee, demonstrating perforations of the triangular fibrocartilage complex (TFCC) and ligaments in the wrist, showing labral tears in the hip, diagnosing ligament tears in the ankle and identifying osteochondral lesions or loose bodies in any of the aforementioned joints. In this article, an overview of techniques of MR arthrography is provided with emphasis on direct MR arthrography using diluted gadolinium as the contrast agent. The current applications of the technique in major peripheral joints are reviewed, with emphasis given to the shoulder joint where the role of this technique has become well established

  20. An overview of MR arthrography with emphasis on the current technique and applicational hints and tips

    Energy Technology Data Exchange (ETDEWEB)

    Sahin, Guelden [Department of Radiology, Faculty of Medicine, Ankara University, Samanpazari, 06100 Ankara (Turkey)]. E-mail: gsahin@medicine.ankara.edu.tr; Demirtas, Mehmet [Department of Hand Surgery, Faculty of Medicine, Ankara University, Samanpazari, 06100 Ankara (Turkey)

    2006-06-15

    Magnetic resonance (MR) arthrography has been investigated in every major peripheral joint of the body, and has been proven to be effective in determining the integrity of intraarticular ligamentous and fibrocartilaginous structures and in the detection or assessment of osteochondral lesions and loose bodies in selected cases. Several methods could be used to create arthrogram effect during MR imaging, however, direct MR arthrography using diluted gadolinium as the contrast agent is the most commonly used technique and is the most reliable of all. MR arthrography is useful for demonstrating labrocapsular-ligamentous abnormalities and distinguishing partial thickness rotator cuff tears from focal full thickness tears in the shoulder, identifying or excluding recurrent tears following meniscal operations in the knee, demonstrating perforations of the triangular fibrocartilage complex (TFCC) and ligaments in the wrist, showing labral tears in the hip, diagnosing ligament tears in the ankle and identifying osteochondral lesions or loose bodies in any of the aforementioned joints. In this article, an overview of techniques of MR arthrography is provided with emphasis on direct MR arthrography using diluted gadolinium as the contrast agent. The current applications of the technique in major peripheral joints are reviewed, with emphasis given to the shoulder joint where the role of this technique has become well established.

  1. Evaluation of patellar cartilage surface lesions: comparison of CT arthrography and fat-suppressed FLASH 3D MR imaging

    International Nuclear Information System (INIS)

    Daenen, B.R.; Ferrara, M.A.; Marcelis, S.; Dondelinger, R.F.

    1998-01-01

    The aim of this study was to evaluate the sensitivity and specificity of fat-suppressed fast low-angle shot (FLASH) 3D MR imaging in the detection of patellar cartilage surface lesions in comparison with CT arthrography. Fifty patients, with or without symptoms of chondromalacia, were prospectively examined by CT arthrography and fat-suppressed 3D gradient-echo MR imaging. All MR examinations were evaluated by three observers, two of them reaching a consensus interpretation. The lesions were graded according to their morphology and their extent. The CT arthrography was considered as the reference examination. For both sets of observers, the final diagnosis of chondromalacia was obtained in 92.5 %. The specificity was 60 % on a patient-by-patient basis. Fissures were missed in 83 and 60 %, respectively, but were isolated findings only in 2.5 % of the cases. Considering ulcers involving more than 50 % of the cartilage thickness, 65 and 88 %, respectively, were recognized. Fat-suppressed FLASH 3D is an adequate pulse sequence for the detection of patellar cartilage ulcers. It can be applied on a routine clinical basis, but it does not show as many fissures as CT arthrography and is less precise for grading of lesions. (orig.)

  2. Evaluation of patellar cartilage surface lesions: comparison of CT arthrography and fat-suppressed FLASH 3D MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Daenen, B.R.; Ferrara, M.A.; Marcelis, S.; Dondelinger, R.F. [Department of Medical Imaging, University Hospital Sart-Tilman, Liege (Belgium)

    1998-07-01

    The aim of this study was to evaluate the sensitivity and specificity of fat-suppressed fast low-angle shot (FLASH) 3D MR imaging in the detection of patellar cartilage surface lesions in comparison with CT arthrography. Fifty patients, with or without symptoms of chondromalacia, were prospectively examined by CT arthrography and fat-suppressed 3D gradient-echo MR imaging. All MR examinations were evaluated by three observers, two of them reaching a consensus interpretation. The lesions were graded according to their morphology and their extent. The CT arthrography was considered as the reference examination. For both sets of observers, the final diagnosis of chondromalacia was obtained in 92.5 %. The specificity was 60 % on a patient-by-patient basis. Fissures were missed in 83 and 60 %, respectively, but were isolated findings only in 2.5 % of the cases. Considering ulcers involving more than 50 % of the cartilage thickness, 65 and 88 %, respectively, were recognized. Fat-suppressed FLASH 3D is an adequate pulse sequence for the detection of patellar cartilage ulcers. It can be applied on a routine clinical basis, but it does not show as many fissures as CT arthrography and is less precise for grading of lesions. (orig.) With 4 figs., 3 tabs., 21 refs.

  3. Magnetic resonance imaging of the shoulder: a review of potential sources of diagnostic errors

    International Nuclear Information System (INIS)

    Carroll, K.W.; Helms, C.A.

    2002-01-01

    Shoulder magnetic resonance (MR) imaging and MR arthrography are frequently utilized in the evaluation of shoulder pain and instability. The clinical scenario and imaging findings may be confusing to clinicians and radiologists and may present diagnostic challenges for those involved in evaluating and treating shoulder pathology. Often rotator cuff and labral abnormalities may be coexistent, clinical manifestations of denervation syndromes may be confusing to clinicians, and normal anatomic variations, imaging pitfalls, and various artifacts may cause dilemmas for the radiologist. This article will review the most frequently encountered mimickers and pitfalls of MR imaging of the shoulder. (orig.)

  4. Arthrography

    Medline Plus

    Full Text Available ... of the radiation while soft tissue, such as muscle, fat and organs, allow more of the x- ... of arthrography? The limitations of arthrography include: Partial tears of the rotator cuff may not be detected ...

  5. The hamatolunate facet: characterization and association with cartilage lesions - magnetic resonance arthrography and anatomic correlation in cadaveric wrists

    Energy Technology Data Exchange (ETDEWEB)

    Pfirrmann, C.W.A. [Department of Radiology, Veterans Administration Medical Center, 3350 La Jolla Village Dr., San Diego, CA 92161 (United States); Orthopedic University Hospital Balgrist, Department of Radiology, Forchstrasse 340, 8008 Zurich (Switzerland); Theumann, N.H.; Chung, C.B.; Trudell, D.J.; Resnick, D. [Department of Radiology, Veterans Administration Medical Center, 3350 La Jolla Village Dr., San Diego, CA 92161 (United States)

    2002-08-01

    The objective of this study was to characterize the appearance of the hamatolunate facet using high-resolution magnetic resonance (MR) arthrography in cadavers and to correlate the presence of this anatomic variant with the presence of osteoarthritis in the wrist. High-resolution MR images of 22 cadaveric wrist specimens were obtained after tri-compartmental arthrography. Two readers in consensus analyzed the MR images and recoded the presence or absence of a hamatolunate facet. Geometric characteristics and cartilage and ligament integrity were analyzed. A third reader, who was blinded to the purpose of the study, recorded cartilage lesions of all the bones of the proximal and distal carpal rows. A hamatolunate facet was present in 11 of 22 wrists (50%). The mean coronal size of the lunate facet at the lunate (type II lunate) was 4.5 mm (range, 2-6 mm). The highest frequencies of cartilage lesions were seen in the scapho-trapezio-trapezoid joint (45.5%) and at the proximal pole of the hamate (54.4% and 40.9% for consensus reading/blinded reading, respectively). In cases with a hamatolunate facet, the frequency of cartilage lesions in the proximal pole of the hamate was 81.8% and 63.6% versus 27.3% and 18.2% without such a facet (chi-squared, P=0.01/P=0.03). No correlation of the presence of a hamatolunate facet with interosseous ligament tears or lesions of the triangular fibrocartilage was seen. In conclusion, the hamatolunate facet is a very common anatomic variant. The presence of a hamatolunate facet is associated with cartilage damage in the proximal pole of the hamate. (orig.)

  6. Wrist arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Fransson, S.G. (Dept. of Diagnostic Radiology, University Hospital, Linkoeping (Sweden))

    1993-03-01

    The ligaments of the proximal row of carpal bones and the triangular fibrocartilage (TFC) strongly influence the function and stability of the wrist. Injury to the ligaments may result in chronic wrist pain or instability. Wrist arthrography is valuable in the investigation of such damage when surgical intervention is considered and plain radiography is unrewarding. There are also several technical modifications of the standard radiocarpal arthrography available. Owing to the possibility of congential perforations and degenerative changes in these ligaments the arthrographic findings should be related to the clinical signs and the age of the patient. CT has less diagnostic importance in this respect while MR imaging is an alternative and may become the method of choice. Both these methods have great potential in the evaluation of soft tissues of the wrist other than the TFC. (orig.).

  7. Cartilage lesions in the ankle joint: comparison of MR arthrography and CT arthrography

    International Nuclear Information System (INIS)

    Schmid, M.R.; Pfirrmann, C.W.A.; Hodler, J.; Zanetti, M.; Vienne, P.

    2003-01-01

    To compare MR arthrography and CT arthrography for the evaluation of cartilage lesions in the ankle joint.Design and patients Thirty-six consecutive patients with clinically suspected cartilage lesions were prospectively included in the study. A 1:1 mixture of diluted gadoteridol (4 mmol/l) and iopamidol (300 mg iodine/ml) was injected. The articular cartilages of the talus, tibia, and fibula were analyzed separately by two musculoskeletal radiologists. A review panel consisting of two musculoskeletal radiologists and an orthopedic surgeon represented the standard of reference. For reader 1 accuracy of MR arthrography in the talus/tibia/fibula (88%/88%/94%) was slightly inferior to CT arthrography (90%/94%/92%). For reader 2, the accuracy was 76%/78%/83% for MR arthrography, and 92%/93%/92% for CT arthrography, respectively. Interobserver agreement for MR arthrography was 79%/74%/89% (kappa 0.47/0.34/0.27), while interobserver agreement for CT arthrography was 89%/90%/89% (kappa 0.69/0.54/0.54). CT arthrography appears to be more reliable than MR arthrography for the detection of cartilage lesions in the ankle joint. (orig.)

  8. Fast MR arthrography using VIBE sequences to evaluate the rotator cuff

    Energy Technology Data Exchange (ETDEWEB)

    Vandevenne, Jan E. [Ziekenhuizen Oost-Limburg, Department of Radiology, Genk (Belgium); Universitair Ziekenhuis Antwerpen, University of Antwerp, Department of Radiology, Edegem (Belgium); Vanhoenacker, Filip; Parizel, Paul M. [Universitair Ziekenhuis Antwerpen, University of Antwerp, Department of Radiology, Edegem (Belgium); Mahachie John, Jestinah M. [University of Hasselt, Centre for Statistics, Diepenbeek (Belgium); Gelin, Geert [Ziekenhuizen Oost-Limburg, Department of Radiology, Genk (Belgium)

    2009-07-15

    The purpose of this paper was to evaluate if short volumetric interpolated breath-hold examination (VIBE) sequences can be used as a substitute for T1-weighted with fat saturation (T1-FS) sequences when performing magnetic resonance (MR) arthrography to diagnose rotator cuff tears. Eighty-two patients underwent direct MR arthrography of the shoulder joint using VIBE (acquisition time of 13 s) and T1-FS (acquisition time of 5 min) sequences in the axial and paracoronal plane on a 1.0-T MR unit. Two radiologists scored rotator cuff tendons on VIBE and T1-FS images separately as normal, small/large partial thickness and full thickness tears with or without geyser sign. T1-FS sequences were considered the gold standard. Surgical correlation was available in a small sample. Sensitivity, specificity, and positive and negative predictive values of VIBE were greater than 92% for large articular-sided partial thickness and full thickness tears. For detecting fraying and articular-sided small partial thickness tears, these parameters were 55%, 94%, 94%, and 57%, respectively. The simple kappa value was 0.76, and the weighted kappa value was 0.86 for agreement between T1-FS and VIBE scores. All large partial and full thickness tears at surgery were correctly diagnosed using VIBE or T1-FS MR images. Fast MR arthrography of the shoulder joint using VIBE sequences showed good concordance with the classically used T1-FS sequences for the appearance of the rotator cuff, in particular for large articular-sided partial thickness tears and for full thickness tears. Due to its very short acquisition time, VIBE may be especially useful when performing MR arthrography in claustrophobic patients or patients with a painful shoulder. (orig.)

  9. Clinical arthrography

    International Nuclear Information System (INIS)

    Arndt, R.; Horns, J.W.; Gold, R.H.; Blaschke, D.D.

    1985-01-01

    This book deals with the method and interpretation of arthrography of the shoulder, knee, ankle, elbow, hip, wrist, and metacarpophalangeal, interphalangeal, and temporomandibular joints. The emphasis is on orthopaedic disorders, usually of traumatic origin, which is in keeping with the application of arthrography in clinical practice. Other conditions, such as inflammatory and degenerative diseases, congenital disorders and, in the case of the hip, arthrography of reconstructive joint surgery, are included. Each chapter is devoted to one joint and provides a comprehensive discussion on the method of arthrography, including single and double contrast techniques where applicable, normal radiographic anatomy, and finally, the interpretation of the normal and the abnormal arthrogram

  10. Is a single direct MR arthrography series in ABER position as accurate in detecting anteroinferior labroligamentous lesions as conventional MR arthography?

    Energy Technology Data Exchange (ETDEWEB)

    Schreinemachers, Saskia A.; Hulst, Victor P.M. van der; Woude, Henk-Jan van der [Onze Lieve Vrouwe Gasthuis, Department of Radiology, Amsterdam (Netherlands); Jaap Willems, W. [Onze Lieve Vrouwe Gasthuis, Orthopaedic Surgery, Amsterdam (Netherlands); Bipat, Shandra [University of Amsterdam, Department of Radiology, Academic Medical Centre, Amsterdam (Netherlands)

    2009-07-15

    The purpose of this study is to retrospectively compare accuracy of single magnetic resonance (MR) arthrography series in Abduction External Rotation (ABER) with conventional MR arthrography for detection and characterisation of anteroinferior labroligamentous lesions, with arthroscopy as reference standard. Inter-observer variability of both protocols was determined. Institutional review board approval was obtained; informed consent was waived. MR arthrograms, including oblique axial fat suppressed T1-weighted images in ABER position and conventional imaging directions of 250 patients (170 men, 80 women; mean age, 36 years), were retrospectively and independently evaluated by three reviewers. Reviewers were blinded to clinical information and arthroscopic results. Labroligamentous lesions were registered in both ABER and MRa. The lesions were sub-classified (Bankart, Perthes, anterior labrum periosteal sleeve avulsion (ALPSA) or lesions not otherwise specified). Inter-observer agreement was assessed by Kappa statistics for all 250 patients. Ninety-two of 250 patients underwent arthroscopy. Sensitivity, specificity and accuracy of ABER versus conventional MR arthrography were calculated and compared using paired McNemar test. Kappa values of the ABER and conventional MR arthrography ranged from 0.44 to 0.56 and 0.44 to 0.62, respectively. According to arthroscopy, 45 of 92 patients had an intact anteroinferior labrum, and in 44 patients, a labroligamentous lesion (eight Bankart, seven Perthes, 29 ALPSA and three lesions not otherwise specified) was diagnosed. There were no statistically significant differences between ABER and conventional MR arthrography regarding sensitivity (85-89%, 89-96%), specificity (82-91%, 84-89%) and overall accuracy (50-62%, 53-63%). The results of a single MR arthrography series in ABER position are comparable with those of conventional MR arthrography for detecting anteroinferior labroligamentous lesions. (orig.)

  11. Evaluation of lesions of the internal ligaments of the wrist; conventional magnetic resonance imaging versus MR arthrography (MRA

    Directory of Open Access Journals (Sweden)

    Heba Ahmed Kamal

    2014-09-01

    Conclusion: MR arthrography is a potent additional tool facilitating the diagnosis of different pathologic entities affecting the major internal ligaments of the wrist joint and helps to reduce arthroscopic interventions.

  12. Knee arthrography today

    International Nuclear Information System (INIS)

    Otto, H.; Kallenberger, R.

    1987-01-01

    The role of knee arthrography today is demonstrated and technical problems are discussed. Among a lot of variants the position of the patient and the choice of contrast media play a great part concerning the result of the examination. Mild complications occur in 0.25% of the examinations, severe and live threatening complications are extremely rare. Diagnosis of meniscal lesions is most important for knee arthrography; arthroscopy and arthrography are complementary examinations and not mutually exclusive, they achieve combined an accuracy of 97-98%. In the same way arthrography is able to evaluate the condropathy of the femoro-tibial joint, whereas accuracy of arthroscopy in the diagnosis of patellar chondropathy is much higher. There is a great reliability of arthrography regarding the evaluation of lesions of the capsule, but accuracy in lesions of the cruciate ligaments is low. Arthrography is very suitable for evaluation of Baker-cysts, since indications for almost occuring internal derangement of the knee are even available. Knee arthrography is a complex and safe procedure with very less discomfort for the patient; it has a central position in the evaluation of lesions of the knee. (orig.) [de

  13. Technical errors in MR arthrography

    International Nuclear Information System (INIS)

    Hodler, Juerg

    2008-01-01

    This article discusses potential technical problems of MR arthrography. It starts with contraindications, followed by problems relating to injection technique, contrast material and MR imaging technique. For some of the aspects discussed, there is only little published evidence. Therefore, the article is based on the personal experience of the author and on local standards of procedures. Such standards, as well as medico-legal considerations, may vary from country to country. Contraindications for MR arthrography include pre-existing infection, reflex sympathetic dystrophy and possibly bleeding disorders, avascular necrosis and known allergy to contrast media. Errors in injection technique may lead to extra-articular collection of contrast agent or to contrast agent leaking from the joint space, which may cause diagnostic difficulties. Incorrect concentrations of contrast material influence image quality and may also lead to non-diagnostic examinations. Errors relating to MR imaging include delays between injection and imaging and inadequate choice of sequences. Potential solutions to the various possible errors are presented. (orig.)

  14. Technical errors in MR arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Hodler, Juerg [Orthopaedic University Hospital of Balgrist, Radiology, Zurich (Switzerland)

    2008-01-15

    This article discusses potential technical problems of MR arthrography. It starts with contraindications, followed by problems relating to injection technique, contrast material and MR imaging technique. For some of the aspects discussed, there is only little published evidence. Therefore, the article is based on the personal experience of the author and on local standards of procedures. Such standards, as well as medico-legal considerations, may vary from country to country. Contraindications for MR arthrography include pre-existing infection, reflex sympathetic dystrophy and possibly bleeding disorders, avascular necrosis and known allergy to contrast media. Errors in injection technique may lead to extra-articular collection of contrast agent or to contrast agent leaking from the joint space, which may cause diagnostic difficulties. Incorrect concentrations of contrast material influence image quality and may also lead to non-diagnostic examinations. Errors relating to MR imaging include delays between injection and imaging and inadequate choice of sequences. Potential solutions to the various possible errors are presented. (orig.)

  15. Scatter radiation exposure during knee arthrography

    International Nuclear Information System (INIS)

    Light, M.C.; Molloi, S.Y.; Yandow, D.R.; Ranallo, F.N.

    1987-01-01

    Knee arthrography, as performed at the authors' institution, was simulated and scattered radiation exposure to a radiologist's gonads, thyroid, and eye lens was measured with a sensitive ionization chamber. Results show that radiologists who regularly conduct knee arthrography examinations can incur doses to the gonads that are less than 6% of the U.S. limits, and to the thyroid and eye that are approximately 10% of the U.S. limits. Since the scatter radiation from overhead imaging of stress views constituted most (greater than or equal to 60%) of the dose to the lens of the eye and the thyroid, spot imaging was evaluated as a substitute for overhead imaging in the assessment of the anterior cruciate ligament. This substitution resulted in no loss of clinical information and has now completely replaced overhead imaging of stress views at this institution

  16. Imaging of the knee joint with emphasis on magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Reiser, M.F. [Radiologische Universitaetsklinik, Rheinische Friedrich-Wilhelms-Univ., Bonn (Germany); Vahlensieck, M. [Radiologische Universitaetsklinik, Rheinische Friedrich-Wilhelms-Univ., Bonn (Germany); Schueller, H. [Radiologische Universitaetsklinik, Rheinische Friedrich-Wilhelms-Univ., Bonn (Germany)

    1992-04-01

    The knee joint is frequently affected by trauma as well as degenerative and inflammatory disorders, involving the internal structures (i.e. ligaments, menisci, cartilage, synovial membrane) and the adjacent bones. Plain radiographs represent an indispensable basis for diagnosis. For further analysis magnetic resonance imaging (MRI) has become the method of choice, and has widely replaced computed tomography, arthrography and stress examinations. Extensive experience has been accumulated in MRI of the knee joint in recent years. In addition, advances in MRI technology have had a major impact on diagnostic accuracy. In this paper, diagnosis of various lesions of the knee joint, such as meniscal and ligamental injuries, aseptic necrosis, lesions of the hyaline cartilage, occult fractures and inflammatory lesions will be discussed. (orig.)

  17. CT-guided puncture for direct MR-arthrography of the shoulder: Description of possible techniques

    Directory of Open Access Journals (Sweden)

    Hauth E

    2016-07-01

    Full Text Available The following report describes the possible techniques of CT-guided puncture for direct magnetic resonance (MR arthrography of the shoulder. CT-guided puncture can be regarded as an alternative technique to fluoroscopic- or ultrasound-guided puncture for MR-arthrography of the shoulder with high efficiency, low dose and extremely low complication rate.

  18. High-resolution magnetic resonance imaging of rotator cuff tears using a microscopy coil. Noninvasive detection without intraarticular contrast material

    International Nuclear Information System (INIS)

    Hitachi, Shin; Takase, Kei; Higano, Shuichi; Takahashi, Shoki; Tanaka, Minoru; Tojo, Yuichi; Tabata, Shiro; Majima, Kazuhiro

    2011-01-01

    The aim of this study was to evaluate the feasibility of high-resolution magnetic resonance imaging (MRI) using a microscopy coil for the diagnosis of rotator cuff tears by comparing the method to conventional MRI and MRI arthrography. A total of 68 shoulders were prospectively studied using a 1.5-T MRI unit. Conventional MRI scans were obtained with a surface coil and high-resolution MRI scans with a microscopy coil. MRI arthrography was performed in 28 shoulders using a surface coil. MRI evaluation of tears of rotator cuff tendons was compared with arthroscopic findings and surgical results. The surgery revealed 40 full-thickness tears, 13 partial-thickness tears, and 15 intact cuffs. In all, 35 (88%) full-thickness tears were correctly diagnosed on conventional MRI and 40 (100%) on high-resolution MRI. MR arthrography delineated 11 of 12 (92%) full-thickness tears. Altogether, 5 (38%) of the partial-thickness tears were detected on conventional MRI, and 12 (92%) were clearly demonstrated on high-resolution MRI. MRI arthrography depicted three (60%) of five partial-thickness tears. High-resolution MRI showed higher sensitivity than conventional MRI (P<0.05) and had values equivalent to those of MRI arthrography for diagnosing partial-thickness tears. High-resolution MRI with a microscopy coil is a feasible, noninvasive technique for diagnosing rotator cuff tears. (author)

  19. Shoulder instability syndrome: comparison of CT, arthrography and MR findings

    International Nuclear Information System (INIS)

    Ortiz, L.; Alcaraz, M.; Preciados, J.L.G.; Garcia Alvarez, A.; Castello, J.

    1995-01-01

    Currently, the two most reliable explorations for diagnosing the lesions that produce shoulder instability are computerized tomography with arthrography and magnetic resonance following intraarticular injection of gadolinium. Dynamic CT arthrography is considered the best method to assess these lesions; MR is a similar procedure but involves certain drawbacks, among them, its cost. The techniques applied in these explorations are reviewed, as are the anatomy of the different components of this joint and the radiological findings leading to a diagnosis of the pathology underlying its instability. (Author)

  20. Sacro-iliac joint arthrography in low back pain: feasibility of MRI guidance

    International Nuclear Information System (INIS)

    Ojala, Risto; Klemola, Rauli; Karppinen, Jaro; Sequeiros, Roberto Blanco; Tervonen, Osmo

    2001-01-01

    Objective: Evaluation of the feasibility of MR-guidance in sacro-iliac joint arthrography in patients whose low back pain is suspected to arise from the sacro-iliac joint (SIJ). Methods and patients: Twenty patients with low back pain underwent MR-guided sacro-iliac joint arthrography. Needles made from titanium (size 20 G, MDTech, USA) were used. For image guidance a 0.23T open-configuration C arm magnet (Proview, Marconi Medical Systems, USA) with special interventional hardware and software package (I-Path 200, Marconi Medical Systems) containing an MR compatible in-room console, large-screen (36'') display, optical navigator and accompanying software with dedicated sequences was used. No other image guidance modalities were used. Results: MR-guided SIJ arthrography was successfully performed in all twenty patients without complications. The optimal imaging sequence both for preoperative and intraoperative images was 3D-Gradient Echo sequence. The dispersal of the injected saline and anaesthetic could be determined inside the joint in all cases with heavily T2-weighted fast spin echo sequence. In the present study, 60% of the patients had significant reduction of pain after sacro-iliac joint arthrography and sacro-iliac joint was considered to be the source of patients low back pain in these patients. Conclusion: The present study shows that MR guidance with open configuration low field scanner is an accurate guiding method for sacro-iliac joint arthrography

  1. Magnetic resonance arthrography and the prevalence of acetabular labral tears in patients 50 years of age and older

    International Nuclear Information System (INIS)

    Jayakar, Rohit; Merz, Alexa; Wang, Dean; Hame, Sharon L.; Plotkin, Benjamin; Seeger, Leanne

    2016-01-01

    Arthroscopy for acetabular labral tears has minimal impact on pain and function in older patients, especially in the setting of concomitant osteoarthritis. Still, many physicians seek this diagnosis with MR arthrography. Our purpose is to assess the frequency of acetabular labral tears in older patients with hip pain and correlate likelihood of labral pathology with severity of osteoarthritis as visualized on conventional radiograph. From 2004 to 2013, 208 hip MRI arthrograms and corresponding radiographs on patients aged 50 years and older were identified. Age, gender, grade and location of labral tear, alpha angle, Toennis grade, and joint space width were documented. Labral tears and alpha angle were identified and measured on MR arthrogram. Toennis grade and joint space width were measured on radiographs. On MR arthrography, true labral tearing was identified in 73 % of patients. There was some degree of labral pathology in 93.3 % of patients, and this increased to 100 % in patients with moderate to severe osteoarthritis, as defined by Toennis grade 2-3 or joint space width ≤ 2 mm. There were no statistically significant correlations between labral tear grade and Toennis grade or joint space width. Given the high frequency of labral pathology and the questionable efficacy of arthroscopic surgical intervention in older patients, MR arthrography should be primarily for those with minimal arthritis on radiograph and potential to benefit from surgery. If further imaging beyond radiographs is necessary in these patients, standard MRI may be a more appropriate imaging tool. (orig.)

  2. Adhesive capsulitis of the shoulder: evaluation with MR arthrography

    International Nuclear Information System (INIS)

    Jung, Joon-Yong; Jee, Won-Hee; Chun, Ho Jong; Kim, Yang-Soo; Chung, Yang Guk; Kim, Jung-Man

    2006-01-01

    The purpose of this study was to determine the usefulness of magnetic resonance (MR) arthrography for diagnosing adhesive capsulitis. Shoulder MR images of 28 patients with (n=14) and without (n=14) adhesive capsulitis were retrospectively analyzed. MR images were assessed for capsule and synovium thickness as well as the width of the axillary recess on oblique coronal fat-suppressed T1-weighted images and T2-weighted images, respectively. On oblique sagittal fat-suppressed T1-weighted images, the width of the rotator interval and the presence of abnormal tissue in the interval were evaluated. Significant differences were found between the two groups in capsule and synovium thickness on both sides of the recess on oblique coronal T2-weighted images (P=0.000), whereas thickness on the humeral aspect showed no significant difference on oblique coronal fat-suppressed T1-weighted images (P=0.109). On oblique coronal T2-weighted images, a cut-off value of 3-mm thickness gave the highest diagnostic accuracy for adhesive capsulitis with sensitivity, specificity, and accuracy of 79% (11/14), 100% (14/14), and 89% (25/28) at the humeral side and 93% (13/14), 86% (12/14), and 89% (25/28) at the glenoid side, respectively. There were significant differences in rotator interval width, presence of abnormal tissue in the rotator interval, and axillary recess width between the two groups (P<0.05). Thickness of capsule and synovium of the axillary recess greater than 3 mm is a practical MR criterion for diagnosing adhesive capsulitis when measured on oblique coronal T2-weighted MR arthrography images without fat suppression. The presence of abnormal tissue in the rotator interval showed high sensitivity but rather low specificity. (orig.)

  3. Articular cartilage defect detectability in human knees with MR-arthrography

    International Nuclear Information System (INIS)

    Engel, A.; Kramer, J.; Stiglbauer, R.; Hajek, P.C.; Imhof, H.

    1993-01-01

    One hundred and thirteen knee joints were examined, of which 48 showed damage of the hyaline cartilage in one or more locations. For the evaluation of the magnetic resonance (MR) arthrographic images we used the macroscopic staging according to Outerbridge, the defect staging according to Bauer, as well as a new MR-arthrographic staging. The results of the evaluation were compared with the surgical findings in 61 knee joints. This revealed a sensitivity of 86 %, a specificity of 100 % and accuracy of 90 %. All lesions that could not be classified on MR-arthrography were of stage-I chondromalacia. (orig.)

  4. Articular cartilage defect detectability in human knees with MR-arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Engel, A. [Orthopaedic Clinic, Univ. of Vienna (Austria); Kramer, J. [MR-Inst., Univ. of Vienna (Austria); Stiglbauer, R. [MR-Inst., Univ. of Vienna (Austria); Hajek, P.C. [MR-Inst., Univ. of Vienna (Austria); Imhof, H. [MR-Inst., Univ. of Vienna (Austria)

    1993-04-01

    One hundred and thirteen knee joints were examined, of which 48 showed damage of the hyaline cartilage in one or more locations. For the evaluation of the magnetic resonance (MR) arthrographic images we used the macroscopic staging according to Outerbridge, the defect staging according to Bauer, as well as a new MR-arthrographic staging. The results of the evaluation were compared with the surgical findings in 61 knee joints. This revealed a sensitivity of 86 %, a specificity of 100 % and accuracy of 90 %. All lesions that could not be classified on MR-arthrography were of stage-I chondromalacia. (orig.)

  5. MR arthrography of elbow: evaluation of the ulnar collateral ligament of elbow

    International Nuclear Information System (INIS)

    Nakanishi, Katsunuki; Masatomi, Takashi; Ochi, Takahiro; Ishida, Takeshi; Hori, Shinichi; Ikezoe, Junpei; Nakamura, Hironobu

    1996-01-01

    Objective. The purpose of this study was to evaluate ulnar collateral ligament (UCL) injury of the elbow in throwing athletes by MRI and MR arthrography. Design. Ten elbows of throwing athletes were examined on both plain MRI and MR saline arthrography and the injuries subsequently surgically proven. Spin-echo (SE) T1-weighted and fast SE T2-weighted coronal images were obtained. Results. The UCL was unclear in all ten cases on T1-weighted MRI. In five cases an avulsion fracture was also found on T1-weighted MRI. On T2-weighted MRI, abnormal high-intensity areas were identified in or around the UCL. On T2-weighted MR arthrography images, extracapsular high-intensity areas, which represent extracapsular leakage, were found in four of five cases with avulsion fracture. At surgery, all these four cases showed avulsion fractures with instability; the other case had a fracture but it was stable and adherent to the humerus. On T2-weighted MR arthrography images, an extracapsular high-intensity area was found in one of the five cases without avulsion fracture. At surgery this patient had a complete tear of the UCL itself. Conclusion. MR arthrography provided additional information for evaluating the degree of UCL injury. (orig.). With 5 figs., 1 tab

  6. Ulnar-sided wrist pain. II. Clinical imaging and treatment

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Atsuya; Souza, Felipe [Brigham and Women' s Hospital, Department of Radiology, Boston, MA (United States); Vezeridis, Peter S.; Blazar, Philip [Brigham and Women' s Hospital, Department of Orthopaedic Surgery, Boston, MA (United States); Yoshioka, Hiroshi [Brigham and Women' s Hospital, Department of Radiology, Boston, MA (United States); University of California-Irvine, Department of Radiological Sciences, Irvine, CA (United States); UC Irvine Medical Center, Department of Radiological Sciences, Orange, CA (United States)

    2010-09-15

    Pain at the ulnar aspect of the wrist is a diagnostic challenge for hand surgeons and radiologists due to the small and complex anatomical structures involved. In this article, imaging modalities including radiography, arthrography, ultrasound (US), computed tomography (CT), CT arthrography, magnetic resonance (MR) imaging, and MR arthrography are compared with regard to differential diagnosis. Clinical imaging findings are reviewed for a more comprehensive understanding of this disorder. Treatments for the common diseases that cause the ulnar-sided wrist pain including extensor carpi ulnaris (ECU) tendonitis, flexor carpi ulnaris (FCU) tendonitis, pisotriquetral arthritis, triangular fibrocartilage complex (TFCC) lesions, ulnar impaction, lunotriquetral (LT) instability, and distal radioulnar joint (DRUJ) instability are reviewed. (orig.)

  7. Magnetic resonance arthrography of the shoulder: accuracy of gadolinium versus saline for rotator cuff and labral pathology

    Energy Technology Data Exchange (ETDEWEB)

    Helms, Clyde A.; McGonegle, Shane J.; Vinson, Emily N.; Whiteside, Michael B. [Duke University Medical Center, Department of Radiology, Durham, NC (United States)

    2011-02-15

    The purpose of this study was to evaluate the necessity of intra-articular gadolinium versus saline alone in magnetic resonance arthrography (MRA) of the shoulder. Our database was reviewed for 100 consecutive shoulder MRA examinations performed between January 2007 and December 2007. Patient information was blinded and images were retrospectively reviewed by at least two radiologists with dedicated musculoskeletal training. T2-weighted (T2W) images were initially analyzed in isolation to simulate MRA with saline alone. After a delay, the full study was analyzed including T1-weighted (T1W) and T2W images. If there was a significant discordance between the two analyses with regard to rotator cuff or labral pathology, the study was again reviewed by all evaluators in consensus to determine if the T1W images offered additional diagnostic information and increased diagnostic confidence. Of the 100 MRA examinations, there were 15 discordant cases. Two cases were discordant with regard to rotator cuff pathology and 13 were discordant on the basis of labral pathology. When the discordant cases were reviewed in consensus, the T2W images appeared to display rotator cuff and labral pathology as definitively as the T1W images. Interobserver and intraobserver variability was favored to have played a role in causing the discordances. MRA of the shoulder performed with joint distention provided by saline alone appears to offer equivalent diagnostic information to MRA performed with gadolinium enhancement. This protocol modification improves efficiency by eliminating several image series and provides a small cost savings by eliminating gadolinium. (orig.)

  8. Magnetic resonance arthrography of the shoulder: accuracy of gadolinium versus saline for rotator cuff and labral pathology

    International Nuclear Information System (INIS)

    Helms, Clyde A.; McGonegle, Shane J.; Vinson, Emily N.; Whiteside, Michael B.

    2011-01-01

    The purpose of this study was to evaluate the necessity of intra-articular gadolinium versus saline alone in magnetic resonance arthrography (MRA) of the shoulder. Our database was reviewed for 100 consecutive shoulder MRA examinations performed between January 2007 and December 2007. Patient information was blinded and images were retrospectively reviewed by at least two radiologists with dedicated musculoskeletal training. T2-weighted (T2W) images were initially analyzed in isolation to simulate MRA with saline alone. After a delay, the full study was analyzed including T1-weighted (T1W) and T2W images. If there was a significant discordance between the two analyses with regard to rotator cuff or labral pathology, the study was again reviewed by all evaluators in consensus to determine if the T1W images offered additional diagnostic information and increased diagnostic confidence. Of the 100 MRA examinations, there were 15 discordant cases. Two cases were discordant with regard to rotator cuff pathology and 13 were discordant on the basis of labral pathology. When the discordant cases were reviewed in consensus, the T2W images appeared to display rotator cuff and labral pathology as definitively as the T1W images. Interobserver and intraobserver variability was favored to have played a role in causing the discordances. MRA of the shoulder performed with joint distention provided by saline alone appears to offer equivalent diagnostic information to MRA performed with gadolinium enhancement. This protocol modification improves efficiency by eliminating several image series and provides a small cost savings by eliminating gadolinium. (orig.)

  9. Low-field MR arthrography of the shoulder joint: technique, indications, and clinical results

    International Nuclear Information System (INIS)

    Kreitner, K.-F.; Thelen, M.; Loew, R.; Runkel, M.; Zoellner, J.

    2003-01-01

    In the age of cost containment and urgent reductions in health care expenditures, new options have to be explored to satisfy both diagnostic requirements and economic limitations. The introduction of low-field MR systems for assessment of joint disorders seemed to be an option for lower costs. The purpose of this article is to summarize available experiences with low-field MR arthrography of the glenohumeral joint with respect to image quality and diagnostic accuracy in detecting labral and rotator cuff lesions. Up to now, there has been only a limited number of studies available dealing with low-field MR arthrography of the glenohumeral joint. They reveal that, despite a minor image quality in comparison with high-field imaging, low-field MR arthrography of the shoulder allows for sufficient evaluation of intra- and extra-articular structures in the detection of major abnormalities such as glenohumeral instability or rotator cuff disease. Furthermore, open-configured MR scanners enable kinematic studies: Besides the analysis of normal motion, pathological findings in patients with instabilities and impingement syndrome can be delineated. They further offer the possibility for performing MR imaging-guided arthrography of the shoulder. This was first described using an open C-arm scanner with a vertically oriented magnetic field so that MR arthrography may be performed in one setting. (orig.)

  10. A New Promising Technique of 3D Isovoxel Imaging Using 3T MRI in the Wrist: Comparison with 3T MR Arthrography

    International Nuclear Information System (INIS)

    Lee, Guen Young; Kim, Baek Hyun; Park, Jong Woong

    2011-01-01

    We wanted to evaluate the usefulness of 3D isovoxel MR imaging using 3T MRI in the wrist joint, as compared with 3T MR arthrography. A total of 33 patients underwent both MR arthrography and 3D isovoxel imaging of the wrist joints using 3T MR, including 11 patients with arthroscopic confirmation. 3D isovoxel MR imaging was performed using an intermediateweighted fast spin echo coronal scan with a 0.4-mm slice thickness and the axial images were reconstructed with a 1-mm slice thickness. One radiologist evaluated for the presence of scapholunate or lunotriquetral ligament tear and she determined the grade of the triangular fibrocartilage complex tear and chondromalacia with its location. We compared the two examinations using kappa values. The rates of detecting wrist injury were similar for both exams with substantial to almost perfect inter-examination agreement (kappa value = 0.864 for scapholunate ligament tear, 0.835 for lunotriquetral ligament tear, 0.799 for TFCC tear and 0.940 for chondromalacia). For the eleven cases that underwent arthroscopy, their results of 3D isovoxel MRI were also similar to that of MR arthrography. 3D isovoxel MR imaging is useful for the evaluation of the wrist joint

  11. A New Promising Technique of 3D Isovoxel Imaging Using 3T MRI in the Wrist: Comparison with 3T MR Arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Guen Young; Kim, Baek Hyun; Park, Jong Woong [Korea University Ansan Hospital, Korea University College of Medicine, Ansan (Korea, Republic of)

    2011-02-15

    We wanted to evaluate the usefulness of 3D isovoxel MR imaging using 3T MRI in the wrist joint, as compared with 3T MR arthrography. A total of 33 patients underwent both MR arthrography and 3D isovoxel imaging of the wrist joints using 3T MR, including 11 patients with arthroscopic confirmation. 3D isovoxel MR imaging was performed using an intermediateweighted fast spin echo coronal scan with a 0.4-mm slice thickness and the axial images were reconstructed with a 1-mm slice thickness. One radiologist evaluated for the presence of scapholunate or lunotriquetral ligament tear and she determined the grade of the triangular fibrocartilage complex tear and chondromalacia with its location. We compared the two examinations using kappa values. The rates of detecting wrist injury were similar for both exams with substantial to almost perfect inter-examination agreement (kappa value = 0.864 for scapholunate ligament tear, 0.835 for lunotriquetral ligament tear, 0.799 for TFCC tear and 0.940 for chondromalacia). For the eleven cases that underwent arthroscopy, their results of 3D isovoxel MRI were also similar to that of MR arthrography. 3D isovoxel MR imaging is useful for the evaluation of the wrist joint

  12. Hip Imaging in Athletes: Sports Imaging Series.

    Science.gov (United States)

    Agten, Christoph A; Sutter, Reto; Buck, Florian M; Pfirrmann, Christian W A

    2016-08-01

    Hip or groin pain in athletes is common and clinical presentation is often nonspecific. Imaging is a very important diagnostic step in the work-up of athletes with hip pain. This review article provides an overview on hip biomechanics and discusses strategies for hip imaging modalities such as radiography, ultrasonography, computed tomography, and magnetic resonance (MR) imaging (MR arthrography and traction MR arthrography). The authors explain current concepts of femoroacetabular impingement and the problem of high prevalence of cam- and pincer-type morphology in asymptomatic persons. With the main focus on MR imaging, the authors present abnormalities of the hip joint and the surrounding soft tissues that can occur in athletes: intraarticular and extraarticular hip impingement syndromes, labral and cartilage disease, microinstability of the hip, myotendinous injuries, and athletic pubalgia. (©) RSNA, 2016.

  13. Magnetic resonance imaging of the shoulder

    International Nuclear Information System (INIS)

    Ilieva, E.

    2015-01-01

    Full text: Magnetic resonance imaging (MRI) is an excellent non-invasive imaging tool that can complement the physical examination in the evaluation of traumatic and non-traumatic injuries of the shoulder. The superb soft tissue contrast and multiplanar capabilities of MRI make it a preferred modality to provide a global assessment of the soft tissue and osseous structures of the shoulder. Learning objectives: to review briefly the anatomy of the shoulder and the specificity of sequences and planes for MRI; to demonstrate the characteristic MR findings of some of the most common shoulder disorders; to indicate how MR arthrography (MRA) of the shoulder can add extra value to the diagnostic process; to outline a systematic approach to the interpretation of the shoulder MR examination. Choosing the most suitable sequences and planes as well as the thorough knowledge of the anatomic structures assist the correct diagnosis of the pathologic disorders of the shoulder which is of great importance for the precise treatment management, surgical versus conservative, as well as for the appropriate surgical approach, open versus arthroscopic

  14. Supraspinatus tendon tears: comparison of US and MR arthrography with surgical correlation

    International Nuclear Information System (INIS)

    Ferrari, Francesco S.; Governi, Simone; Burresi, Francesca; Vigni, Francesco; Stefani, Paolo

    2002-01-01

    The aim of this study was to compare the diagnostic reliability of US with MR arthrography in diagnosing supraspinatus tendon tears. Surgical findings were used as the gold standard in detecting tears. A total of 44 patients were assessed with transverse and longitudinal US scans with respect to the long axis of the rotator cuff tendons and then examined with MR arthrography. This technique involved free-hand injection of contrast medium into the shoulder joint. At surgery 20 incomplete and 24 complete tears were observed. Ultrasound offered good results for the large tears, but its sensitivity decreased proportionally with the size of the tears. Magnetic resonance arthrography correctly diagnosed 43 tears, whereas only one false-negative diagnosis of tendinosis was made for a partial tear on the bursal side. Since it improves the diagnosis of small tears, MR arthrography must be performed on all patients for whom surgical repair is necessary in order to restore normal functions. (orig.)

  15. Supraspinatus tendon tears: comparison of US and MR arthrography with surgical correlation

    Energy Technology Data Exchange (ETDEWEB)

    Ferrari, Francesco S.; Governi, Simone; Burresi, Francesca; Vigni, Francesco; Stefani, Paolo [Department of Radiologic and Orthopaedic-Rehabilitative Sciences, University Hospital Siena (Italy)

    2002-05-01

    The aim of this study was to compare the diagnostic reliability of US with MR arthrography in diagnosing supraspinatus tendon tears. Surgical findings were used as the gold standard in detecting tears. A total of 44 patients were assessed with transverse and longitudinal US scans with respect to the long axis of the rotator cuff tendons and then examined with MR arthrography. This technique involved free-hand injection of contrast medium into the shoulder joint. At surgery 20 incomplete and 24 complete tears were observed. Ultrasound offered good results for the large tears, but its sensitivity decreased proportionally with the size of the tears. Magnetic resonance arthrography correctly diagnosed 43 tears, whereas only one false-negative diagnosis of tendinosis was made for a partial tear on the bursal side. Since it improves the diagnosis of small tears, MR arthrography must be performed on all patients for whom surgical repair is necessary in order to restore normal functions. (orig.)

  16. Intrinsic ligament and triangular fibrocartilage complex tears of the wrist: comparison of MDCT arthrography, conventional 3-T MRI, and MR arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ryan K.L.; Ng, Alex W.H.; Tong, Cina S.L.; Griffith, James F. [The Chinese University of Hong Kong, Department of Imaging and Interventional Radiology, Prince Of Wales Hospital, Shatin (China); Tse, W.L.; Wong, C.; Ho, P.C. [The Chinese University of Hong Kong, Department of Imaging and Interventional Radiology, Prince Of Wales Hospital, Shatin (China); The Chinese University of Hong Kong, Department of Orthopedics, Prince Of Wales Hospital, Shatin (China)

    2013-09-15

    This study compares the diagnostic performance of multidetector CT arthrography (CTA), conventional 3-T MR and MR arthrography (MRA) in detecting intrinsic ligament and triangular fibrocartilage complex (TFCC) tears of the wrist. Ten cadaveric wrists of five male subjects with an average age 49.6 years (range 26-59 years) were evaluated using CTA, conventional 3-T MR and MRA. We assessed the presence of scapholunate ligament (SLL), lunotriquetral ligament (LTL), and TFCC tears using a combination of conventional arthrography and arthroscopy as a gold standard. All images were evaluated in consensus by two musculoskeletal radiologists with sensitivity, specificity, and accuracy being calculated. Sensitivities/specificity/accuracy of CTA, conventional MRI, and MRA were 100 %/100 %/100 %, 66 %/86 %/80 %, 100 %/86 %/90 % for the detection of SLL tear, 100 %/80 %/90 %, 60 %/80 %/70 %, 100 %/80 %/90 % for the detection of LTL tear, and 100 %/100 %/100 %, 100 %/86 %/90 %, 100 %/100 %/100 % for the detection of TFCC tear. Overall CTA had the highest sensitivity, specificity, and accuracy among the three investigations while MRA performed better than conventional MR. CTA also had the highest sensitivity, specificity, and accuracy for identifying which component of the SLL and LTL was torn. Membranous tears of both SLL and LTL were better visualized than dorsal or volar tears on all three imaging modalities. Both CT and MR arthrography have a very high degree of accuracy for diagnosing tears of the SLL, LTL, and TFCC with both being more accurate than conventional MR imaging. (orig.)

  17. The diagnostic value of magnetic resonance arthrography of the shoulder in detection and grading of SLAP lesions: Comparison with arthroscopic findings

    International Nuclear Information System (INIS)

    Amin, Mohammed Farghally; Youssef, Ahmed Omar

    2012-01-01

    Purpose: The purpose of the study is to determine the usefulness of magnetic resonance arthrography (MRA) in diagnosis and grading of superior labrum anterior to posterior (SLAP) lesions of the Glenoid Labrum Compared with surgery Material and methods: This was a prospective study including fifty nine clinically diagnosed SLAP patients. The study was done during the period from January 2008 to June 2010. All patients were submitted to history taking, clinical examination and conventional MRI examination of the shoulder, MRA was done in patients with negative conventional MRI, all of these patients underwent arthroscopy for diagnosis wither open or arthroscopy for diagnosis and treatment and results were compared with MRA findings. Main outcome measures: Sensitivity, specificity, positive and negative predictive values, and overall accuracy of MR arthrography in detection and grading of SLAP lesions of the gelnoid labrum. Results: Out of fifty nine patients, 25 patients had positive MR findings in conventional MRI, and 34 patients had negative MR findings, who underwent MR arthrography; 10 out of them had normal arthrogram (only 6 of them underwent arthroscopy), 22 had SLAP (superior labrum anterior to posterior) lesions, one had Bankart's lesion and one had internal impingement syndrome. These results were compared with arthroscopy results. The overall sensitivity of MRA in detection of SLAP lesions was 90% while the specificity was 50%, negative predictive value (NPV) was 66.6% and positive predicative value (PPV) was 81.8%. MRA and arthroscopy results were concurrent in 79.3% patients. Conclusion: MR arthrography is a sensitive minimally invasive technique for detection and grading of SLAP lesions, it can help in avoiding patients unnecessary diagnostic arthroscopy

  18. The diagnostic value of magnetic resonance arthrography of the shoulder in detection and grading of SLAP lesions: Comparison with arthroscopic findings

    Energy Technology Data Exchange (ETDEWEB)

    Amin, Mohammed Farghally, E-mail: Mohammed_amin37@yahoo.com [Department of Radiodiagnosis ElMinya University, ElMinya High Road, ElMinya (Egypt); Youssef, Ahmed Omar [Department of Orthropedic Surgery El Minya University, ElMinya (Egypt)

    2012-09-15

    Purpose: The purpose of the study is to determine the usefulness of magnetic resonance arthrography (MRA) in diagnosis and grading of superior labrum anterior to posterior (SLAP) lesions of the Glenoid Labrum Compared with surgery Material and methods: This was a prospective study including fifty nine clinically diagnosed SLAP patients. The study was done during the period from January 2008 to June 2010. All patients were submitted to history taking, clinical examination and conventional MRI examination of the shoulder, MRA was done in patients with negative conventional MRI, all of these patients underwent arthroscopy for diagnosis wither open or arthroscopy for diagnosis and treatment and results were compared with MRA findings. Main outcome measures: Sensitivity, specificity, positive and negative predictive values, and overall accuracy of MR arthrography in detection and grading of SLAP lesions of the gelnoid labrum. Results: Out of fifty nine patients, 25 patients had positive MR findings in conventional MRI, and 34 patients had negative MR findings, who underwent MR arthrography; 10 out of them had normal arthrogram (only 6 of them underwent arthroscopy), 22 had SLAP (superior labrum anterior to posterior) lesions, one had Bankart's lesion and one had internal impingement syndrome. These results were compared with arthroscopy results. The overall sensitivity of MRA in detection of SLAP lesions was 90% while the specificity was 50%, negative predictive value (NPV) was 66.6% and positive predicative value (PPV) was 81.8%. MRA and arthroscopy results were concurrent in 79.3% patients. Conclusion: MR arthrography is a sensitive minimally invasive technique for detection and grading of SLAP lesions, it can help in avoiding patients unnecessary diagnostic arthroscopy.

  19. Cone-beam computed tomography arthrography: an innovative modality for the evaluation of wrist ligament and cartilage injuries

    Energy Technology Data Exchange (ETDEWEB)

    Ramdhian-Wihlm, Reeta [University Hospital of Strasbourg, Department of Orthopedic Surgery, Strasbourg (France); Le Minor, Jean-Marie [University of Strasbourg, Institute of Anatomy, Strasbourg (France); University of Strasbourg, Faculty of Dentistry, Strasbourg (France); Schmittbuhl, Matthieu [University of Strasbourg, Faculty of Dentistry, Strasbourg (France); Jeantroux, Jeremy; Veillon, Francis; Dosch, Jean-Claude; Dietemann, Jean-Louis; Bierry, Guillaume [University Hospital of Strasbourg, Department of Radiology, Strasbourg (France); Mahon, Peter Mac [Massachusetts General Hospital, Department of Musculoskeletal Radiology, Boston, MA (United States)

    2012-08-15

    Cone-beam computed tomography (CBCT) has become an important modality in dento-facial imaging but remains poorly used in the exploration of the musculoskeletal system. The purpose of this study was to prospectively evaluate the performance and radiation exposure of CBCT arthrography in the evaluation of ligament and cartilage injuries in cadaveric wrists, with gross pathology findings as the standard of reference. Conventional arthrography was performed under fluoroscopic guidance on 10 cadaveric wrists, followed by MDCT acquisition and CBCT acquisition. CBCT arthrography and MDCT arthrography images were independently analyzed by two musculoskeletal radiologists working independently and then in consensus. The following items were observed: scapholunate and lunotriquetral ligaments, triangular fibrocartilage complex (TFCC) (tear, integrity), and proximal carpal row cartilage (chondral tears). Wrists were dissected and served as the standard of reference for comparisons. Interobserver agreement, sensitivity, specificity, and accuracy were determined. Radiation dose (CTDI) of both modalities was recorded. CBCT arthrography provides equivalent results to MDCT arthrography in the evaluation of ligaments and cartilage with sensitivity and specificity between 82 and 100%, and interobserver agreement between 0.83 and 0.97. However, radiation dose was significantly lower (p < 0.05) for CBCT arthrography than for MDCT arthrography with a mean CTDI of 2.1 mGy (range 1.7-2.2) versus a mean of 15.1 mGy (range 14.7-16.1). CBCT arthrography appears to be an innovative alternative to MDCT arthrography of the wrist as it allows an accurate and low radiation dose evaluation of ligaments and cartilage. (orig.)

  20. Labral-Ligamentous Complex of the Shoulder. Evaluation with double oblique axial MR arthrography. Technical Note

    International Nuclear Information System (INIS)

    Sasaki, Taisuke; Saito, Y.; Yodono, H.; Prado, G.L.M.; Miura, H.; Itabashi, Y.; Ishibashi, Y.

    2003-01-01

    Purpose: To assess the ability of double oblique axial (DOA) MR arthrography in evaluating labral-ligamentous complex compared with conventional axial (CA) MR arthrography. Material and Methods: MR arthrography of 51 shoulders, subsequently examined with arthroscopy, were retrospectively reviewed. DOA imaging was performed in all 51 shoulders and both DOA and CA imaging in 37 using a 1.5 T unit with gradient recalled-echo T2*-weighted sequences. DOA imaging was performed using perpendicular planes to the long axis of the glenoid fossa obtained by an oblique sagittal scout image. We compared the ability of DOA with that of CA MR arthrography to assess labral injuries and to demonstrate the whole length of the anterior band of the inferior glenohumeral ligament (AIGHL), which were shown to be intact by arthroscopy. Results: For anterior labral injuries, sensitivity and specificity were 87% and 93% with CA, and 94% and 100% with DOA imaging, respectively. For posterior labral injuries, sensitivity and specificity were 47% and 100% with CA, and 79% and 96% with DOA imaging, respectively. There were no statistically significant differences between CA and DOA images, except for the ability to diagnose posterior labral injuries, where DOA imaging had a significant superior sensitivity (p = 0.0327). DOA images also demonstrated the whole length of the intact AIGHL in 10 of 11 shoulders, while CA imaging showed this in only 3 of 11. Conclusion: DOA imaging was equal or better than CA imaging for evaluating the labral-ligamentous complex

  1. Ultra-high resolution C-Arm CT arthrography of the wrist: Radiation dose and image quality compared to conventional multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Werncke, Thomas, E-mail: Werncke.Thomas@mh-hannover.de [Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover (Germany); Sonnow, Lena; Meyer, Bernhard C. [Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover (Germany); Lüpke, Matthias [University of Veterinary Medicine Hannover, Institute for General Radiology and Medical Physics, Bischofsholer Damm 15, 30173 Hannover (Germany); Hinrichs, Jan; Wacker, Frank K.; Falck, Christian von [Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover (Germany)

    2017-04-15

    Objective: Objective of this phantom and cadaveric study was to compare the effective radiation dose (ED) and image quality (IQ) between C-arm computed tomography (CACT) using an ultra-high resolution 1 × 1 binning with a standard 16-slice CT (MDCT) arthrography of the wrist. Methods: ED was determined with thermoluminescence dosimetry using an anthropomorphic phantom and different patient positions. Imaging was conducted in 10 human cadaveric wrists after tri-compartmental injection of diluted iodinated contrast material and a wire phantom. IQ of MDCT was compared with CACT reconstructed with a soft (CACT1) and sharp (CACT2) kernel. High and low contrast resolution was determined. Three radiologists assessed IQ of wrist structures and occurrence of image artifacts using a 5-point Likert scale. Results: ED of MDCT was comparable to standard CACT (4.3 μSv/3.7 μSv). High contrast resolution was best for CACT2, decreased to CACT1 and MDCT. Low contrast resolution increased between CACT2 and MDCT (P < 0.001). IQ was best for CACT2 (1.3 ± 0.5), decreased to CACT1 (1.9 ± 0.6) and MDCT (3.5 ± 0.6). Non-compromising artifacts were only reported for CACT. Conclusions: The results of this phantom and cadaveric study indicate that ultra-high resolution C-Arm CT arthrography of the wrist bears the potential to outperform MDCT arthrography in terms of image quality and workflow at the cost of mildly increasing image artifacts while radiation dose to the patient is comparably low for both, MDCT and C-Arm CT.

  2. MR and MR arthrography to identify degenerative and posttraumatic diseases in the shoulder joint

    International Nuclear Information System (INIS)

    Lee, Shi-Uk; Lang, Philipp

    2000-01-01

    MR imaging provides a comprehensive evaluation of a wide spectrum of both intraarticular and extraarticular pathology of the shoulder. MR imaging enables the detection or exclusion of degenerative and posttraumatic diseases of the shoulder with a reasonable accuracy. MR arthrography is useful in the visualization of subtle anatomic details and further improves the differentiation. In this article, findings of MR imaging and MR arthrography of degenerative and posttraumatic shoulder diseases (impingement syndrome, rotator cuff tears, and glenohumeral instability) has been reviewed

  3. [Technique and value of direct MR arthrography applying articular distraction].

    Science.gov (United States)

    Becce, Fabio; Wettstein, Michael; Guntern, Daniel; Mouhsine, Elyazid; Palhais, Nuno; Theumann, Nicolas

    2010-02-24

    Direct MR arthrography has a better diagnostic accuracy than MR imaging alone. However, contrast material is not always homogeneously distributed in the articular space. Lesions of cartilage surfaces or intra-articular soft tissues can thus be misdiagnosed. Concomitant application of axial traction during MR arthrography leads to articular distraction. This enables better distribution of contrast material in the joint and better delineation of intra-articular structures. Therefore, this technique improves detection of cartilage lesions. Moreover, the axial stress applied on articular structures may reveal lesions invisible on MR images without traction. Based on our clinical experience, we believe that this relatively unknown technique is promising and should be further developed.

  4. Value and limits of knee arthrography

    International Nuclear Information System (INIS)

    Fischedick, O.

    1981-01-01

    In the view of modern knowledges of biomechanic of the knee and the introduce of arthroscopy, the possibilities of arthrography will be discussed. The value of arthrography is not reduced, especially for the cruciate ligaments. Arthroscopy should follow arthrography in uncertain cases. (orig.) [de

  5. Multimodality imaging of the postoperative shoulder

    Energy Technology Data Exchange (ETDEWEB)

    Woertler, Klaus [Technische Universitaet Muenchen, Department of Radiology, Munich (Germany)

    2007-12-15

    Multimodality imaging of the postoperative shoulder includes radiography, magnetic resonance (MR) imaging, MR arthrography, computed tomography (CT), CT arthrography, and ultrasound. Target-oriented evaluation of the postoperative shoulder necessitates familiarity with surgical techniques, their typical complications and sources of failure, knowledge of normal and abnormal postoperative findings, awareness of the advantages and weaknesses with the different radiologic techniques, and clinical information on current symptoms and function. This article reviews the most commonly used surgical procedures for treatment of anterior glenohumeral instability, lesions of the labral-bicipital complex, subacromial impingement, and rotator cuff lesions and highlights the significance of imaging findings with a view to detection of recurrent lesions and postoperative complications in a multimodality approach. (orig.)

  6. The Usefulness of Dynamic Cine-Arthrography for Wrist Instability as Correlated with Arthroscopic Palmer Classification

    Energy Technology Data Exchange (ETDEWEB)

    Kim TaeYeon; Lee, Guen Young; Kim, Baek Hyun; Park, Jong Woong; Seo, Bo Kyoung; Cha, Sang Hoon [Korea University Ansan Hospital, Korea University College of Medicine, Ansan (Korea, Republic of)

    2011-05-15

    To introduce dynamic cine-arthrography and compare it with MR arthrography in the diagnosis of intrinsic ligament and triangular fibrocartilage complex tears, based on arthroscopic findings. A total of thirty-eight wrists of 38 patients who had undergone both dynamic cine-arthrography and MR arthrography were enrolled. Dynamic cinearthrography was performed after puncture of the radiocarpal joint by slow injection of contrast under continuous fluoroscopic guidance during passive wrist exercise. We obtained 1.5- or 3-T MR arthrography with fat-suppressed T1-weighted coronal and axial images. We evaluated scapholunate and lunotriquetral ligaments and triangular fibrocartilage complex tears according to the Palmer classification system. Based on the arthroscopic findings, we compared the diagnostic values between the two examinations using Kappa values. The overall sensitivity and specificity of diagnosis of intrinsic ligament tears was similar between dynamic cine-arthrography and MR arthrography (scapholunate ligament: sensitivity 66.7% vs. 80%, specificity 100% vs. 95.7%, lunotriquetral ligament: sensitivity 75.0% vs. 75.0%, specificity 94.1% vs. 91.2%). For triangular fibrocartilage complex tears, all diagnostic values were the same (sensitivity 96.4%, specificity 100%). The inter-examination agreement was substantial to perfect (kappa value 1.000). Dynamic cine-arthrography is valuable in the diagnosis of intrinsic ligament and triangular fibrocartilage complex tears compared to MR arthrography.

  7. Supraspinatus tendon tears: comparison of 3D US and MR arthrography with surgical correlation

    International Nuclear Information System (INIS)

    Kang, Chang Ho; Kim, Sam Soo; Kim, Jung Hyuk; Chung, Kyoo Byung; Kim, Yun Hwan; Oh, Yu-Whan; Jeong, Woong-Kyo; Kim, Baek Hyun

    2009-01-01

    The objective of the study was to compare the diagnostic reliability of 3D US with MR arthrography in diagnosing supraspinatus tendon tears, with arthroscopic findings used as the standard. In a prospective study 50 patients who later underwent arthroscopic surgery of the rotator cuff were examined pre-operatively by 3D US with MR arthrography. The presence or absence of a full- or partial-thickness supraspinatus tendon tear and the tear size as demonstrated by each imaging and arthroscopy was recorded. The tear size was divided into three grades: small ( 3 cm). The arthroscopic diagnosis was a full-thickness tear in 40 patients, partial-thickness tears in 5, and intact supraspinatus tendon in 5. 3D US correctly diagnosed 35 out of 40 full-thickness tears and MR arthrography 39 out of 40 full-thickness tears. Regarding partial-thickness tears, 3D US underestimated 2 cases as no tear and overestimated 1 case as a full-thickness tear. MR arthrography underestimated 1 case as a partial-thickness tear and overestimated 2 cases as full-thickness and partial-thickness tears respectively. 3D US and MR arthrography yield a sensitivity for full-thickness tears of 87.5% and 97.5% with specificity of 90.0% and 90.0%. Based on the grading system, 3D US measurements correctly predicted the tear size of 23 (65.7%) of the 35 full-thickness tears and MR arthrography 30 (75.0%) of the 39 full-thickness tears. Three-dimensional ultrasound seems to be a promising imaging modality comparable to MR arthrography for the assessment of the supraspinatus tendon tears. (orig.)

  8. Supraspinatus tendon tears: comparison of 3D US and MR arthrography with surgical correlation

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Chang Ho [Kangwon National University Hospital, Department of Radiology, Kangwon-do (Korea); Korea University Anam Hospital, Korea University College of Medicine, Department of Radiology, Seoul (Korea); Kim, Sam Soo [Kangwon National University Hospital, Department of Radiology, Kangwon-do (Korea); Kim, Jung Hyuk; Chung, Kyoo Byung; Kim, Yun Hwan; Oh, Yu-Whan [Korea University Anam Hospital, Korea University College of Medicine, Department of Radiology, Seoul (Korea); Jeong, Woong-Kyo [Korea University Anam Hospital, Korea University College of Medicine, Orthopaedic Surgery, Seoul (Korea); Kim, Baek Hyun [Korea University Ansan Hospital, Korea University College of Medicine, Department of Radiology, Ansan City (Korea)

    2009-11-15

    The objective of the study was to compare the diagnostic reliability of 3D US with MR arthrography in diagnosing supraspinatus tendon tears, with arthroscopic findings used as the standard. In a prospective study 50 patients who later underwent arthroscopic surgery of the rotator cuff were examined pre-operatively by 3D US with MR arthrography. The presence or absence of a full- or partial-thickness supraspinatus tendon tear and the tear size as demonstrated by each imaging and arthroscopy was recorded. The tear size was divided into three grades: small (<1 cm), medium (1-3 cm), and large (>3 cm). The arthroscopic diagnosis was a full-thickness tear in 40 patients, partial-thickness tears in 5, and intact supraspinatus tendon in 5. 3D US correctly diagnosed 35 out of 40 full-thickness tears and MR arthrography 39 out of 40 full-thickness tears. Regarding partial-thickness tears, 3D US underestimated 2 cases as no tear and overestimated 1 case as a full-thickness tear. MR arthrography underestimated 1 case as a partial-thickness tear and overestimated 2 cases as full-thickness and partial-thickness tears respectively. 3D US and MR arthrography yield a sensitivity for full-thickness tears of 87.5% and 97.5% with specificity of 90.0% and 90.0%. Based on the grading system, 3D US measurements correctly predicted the tear size of 23 (65.7%) of the 35 full-thickness tears and MR arthrography 30 (75.0%) of the 39 full-thickness tears. Three-dimensional ultrasound seems to be a promising imaging modality comparable to MR arthrography for the assessment of the supraspinatus tendon tears. (orig.)

  9. Arthrography of the equine shoulder joint

    International Nuclear Information System (INIS)

    Nixon, A.J.; Spencer, C.P.

    1990-01-01

    Techniques and normal radiographic anatomy for positive and double contrast shoulder arthrography in horses were evaluated. General anaesthesia was used for most radiographic projections of the shoulder. The mediolateral projection provided the most information during arthrography, although the supinated mediolateral view occasionally allowed better definition of the cartilage surfaces on the medial aspects of the humeral head. The craniocaudal mediolateral oblique and caudocranial projections provided limited additional information. Water soluble non-ionic contrast agents, such as metrizamide and iohexol, were suitable for shoulder arthrography; iohexol resulted in less synovitis and lameness. Arthrography in cases of osteochondrosis and osteochondritis dissecans allowed better evaluation of cartilage attachment to subchondral bone, better evaluation of the length and depth of cartilage lesions and more accurately defined the site and shape of osteocartilaginous free bodies. Cartilage thickening without detachment from the subchondral bone could only be determined by arthrography. Although these thick cartilage regions may later dissect from the subchondral bone, most cases where the cartilage was firmly adherent were not candidates for surgical debridement and carried a favourable prognosis. The determination of a free flap by arthrography indicated the need for surgery. Extensive humeral and glenoid cavity lesions were better defined by arthrography, allowing a rational decision between surgical debridement or euthanasia. Using arthrography, evaluation of the size and patency of the communicating canal to a subchondral cystic defect better separated cases with long, narrow and poorly patent canals for conservative rather than surgical therapy

  10. Value of knee joint arthrography

    International Nuclear Information System (INIS)

    Luzsa, Gyoergy; Kiss Toth, Peter

    1985-01-01

    On the basis of the literature and the analysis of 204 examinations, the method and clinical application of knee joint arthrography are reviewed. 50 out of the 54 operated cases were perfectly diagnosed. The double contrast knee joint arthrography can be applied to detect meniscus changes, popliteal cysts, synovial disorders and chondral defects. The effectiveness of arthrography and arthroscopy was compared and the introduction of the former in each county seat is suggested. (author)

  11. MR arthrography of the knee

    International Nuclear Information System (INIS)

    Kramer, J. Jr.; Engel, A. Jr.; Stiglbauer, R.; Prayer, L. Jr.; Hajek, P. Jr.; Imhof, H.

    1991-01-01

    This paper reports on MR imaging which has gained increasing importance as a diagnostic instrument in orthopedics. The key to joint diagnostics - the evaluation of hyaline articular cartilage - however, has not been touched sufficiently by this development. Fundamental studies were done and 140 patients were examined with MR imaging after intraarticular administration of contrast agent. Hyaline cartilage, cruciate ligaments, and menisci were assessed before and after injection of a 2-mmol/L Gd-DTPA solution, and the results were compared with those of arthroscopy/arthrotomy. MR arthrography provided superior image quality compared with plain MR imaging. This resulted in an improved delineation of intraarticular structures, especially of cartilage defects

  12. The posterior transtriceps approach for elbow arthrography: a forgotten technique?

    International Nuclear Information System (INIS)

    Lohman, M.; Borrero, C.; Casagranda, B.; Rafiee, B.; Towers, J.

    2009-01-01

    To evaluate the technical feasibility of performing elbow MR arthrography via a posterior approach through the triceps. The images of 19 patients with elbow MR arthrography via a posterior transtriceps approach were retrospectively studied. The injections were performed by four musculoskeletal radiologists, using fluoroscopic guidance and a 22- or 25-gauge needle. The fluoroscopic and subsequent MR images were reviewed by two musculoskeletal radiologists and evaluated for adequacy of joint capsular distention, degree and location of contrast leakage, and presence of gas bubbles. The injection was diagnostic in all 19 patients, with a sufficient amount of contrast agent seen in the elbow joint. No significant contrast leakage occurred in 12 patients who received injections of 8 cc or less of contrast agent, but moderate contrast leakage occurred in 6/7 patients who received injections of greater than 8 cc. Contrast leakage generally occurred within the triceps myotendinous junction. No gas bubbles were identified in the injected joints. Patients often present for MR arthrography of the elbow with medial or lateral elbow pain. Contrast leakage during a radiocapitellar approach may complicate evaluation of the lateral collateral ligament or the common extensor tendon origin. Transtriceps MR arthrography offers an alternative to the more commonly used radiocapitellar approach. With injected volumes not exceeding 8 cc, the risk of significant contrast leakage is small. An advantage of the transtriceps injection is that contrast leakage through the posterior needle tract does not interfere with evaluation of the lateral structures. (orig.)

  13. Magnetic resonance imaging of the triangular fibrocartilage complex. Usefulness of the fat suppression MRI

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Toshiyasu [Fujita Health Univ., Nagoya (Japan). Second Hospital; Yabe, Yutaka; Horiuchi, Yukio; Kikuchi, Yoshito; Makita, Satoo

    1996-08-01

    Advances in magnetic resonance imaging (MRI) now allow for the visualization of small structures, such as the triangular fibrocartilage complex (TFCC) of the wrist. Recent investigators suggested that MRI is useful in delineation of the TFCC itself and its abnormality, and supported that diagnostic value of MRI for the TFCC tears is almost equal to those of arthrography and arthroscopy. In contrast, there were several reports that representation of the TFCC in MRI was less worth than in arthrography. Further, it was reported that MRI was not useful because abnormal findings existed at normal volunteers` wrists. Recent development of the pulse sequence is remarkable, such as gradient echo, fast spin echo and fat suppression method. However, as the previous MR studies of the TFCC mainly using conventional spin echo pulse sequence, there were a few comparison of each pulse sequence and we do not know how each pulse sequence delineates the TFCC. Therefore, we studied MRI of the TFCC using several pulse sequence in normal volunteers, and compared MR slices of the TFCC with corresponding histological sections to evaluate shape detectability of MRI. (J.P.N.)

  14. Cerebral air embolism after arthrography of the ankle

    NARCIS (Netherlands)

    Müller, Marcella C. A.; Lagarde, Sjoerd M.; Germans, Menno R.; Juffermans, Nicole P.

    2010-01-01

    Background: The accidental migration of air from the venous circulation into the systemic arterial circulation is called paradoxical air embolism. This is a potential disastrous complication after diagnostic and surgical procedures. Arthrography has been a useful technique in joint imaging for the

  15. Wrist arthrography: a simple method

    Energy Technology Data Exchange (ETDEWEB)

    Berna-Serna, Juan D.; Reus, Manuel; Alonso, Jose [Virgen de la Arrixaca University Hospital, Department of Radiology, El Palmar (Murcia) (Spain); Martinez, Francisco; Domenech-Ratto, Gines [University of Murcia, Department of Human Anatomy, Faculty of Medicine, Murcia (Spain)

    2006-02-01

    A technique of wrist arthrography is presented using an adhesive marker-plate with radiopaque coordinates to identify precisely sites for puncture arthrography of the wrist and to obviate the need for fluoroscopic guidance. Radiocarpal joint arthrography was performed successfully in all 24 cases, 14 in the cadaveric wrists and 10 in the live patients. The arthrographic procedure described in this study is simple, safe, and rapid, and has the advantage of precise localisation of the site for puncture without need for fluoroscopic guidance. (orig.)

  16. MR imaging of the shoulder: Spectrum of abnormalities in 65 patients and correlation with arthrography and surgery

    International Nuclear Information System (INIS)

    Zlatkin, M.B.; Reicher, M.A.; Kellerhouse, L.E.; Resnick, D.; Sartoris, D.J.

    1987-01-01

    MR imaging has previously been used to demonstrate the appearance of the normal shoulder. In this investigation the authors employed MR imaging in 65 consecutive patients with shoulder pain. Subsequent arthrography was performed in 31 patients and surgery in 15. Clinical follow-up was obtained in 35 patients treated conservatively. MR imaging was highly accurate in depicting the spectrum of rotator cuff abnormalities associated with mechanical impingment, including both large and small rotator cuff tears as well as tendinitis. Abnormalities of the capsular mechanisms, osseous tumors, ostenonecrosis, and injuries to the supporting musculature were also well depicted. Considerable potential exists for MR imaging in evaluating shoulder joint disease

  17. Comparison of three dimensional isotropic and two dimensional conventional indirect MR arthrography for the diagnosis of rotator cuff tears

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ji Hyun; Yoon, Young Cheol; Kwon, Jong Won; Yoo, Jae Chul [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Cha, Jang Kyu [Dept. of Radiology, Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of); Jee, Suk Kyoung [Joeun Madi Hospital, Seoul (Korea, Republic of)

    2014-12-15

    To compare the accuracy between a three-dimensional (3D) indirect isotropic T1-weighted fast spin-echo (FSE) magnetic resonance (MR) arthrography and a conventional two-dimensional (2D) T1-weighted sequences of indirect MR arthrography for diagnosing rotator cuff tears. The study was approved by our Institutional Review Board. In total, 205 patients who had undergone indirect shoulder MR arthrography followed by arthroscopic surgery for 206 shoulders were included in this study. Both conventional 2D T1-weighted FSE sequences and 3D isotropic T1-weighted FSE sequence were performed in all patients. Two radiologists evaluated the images for the presence of full- or partial-thickness tears in the supraspinatus-infraspinatus (SSP-ISP) tendons and tears in the subscapularis (SSC) tendons. Using the arthroscopic findings as the reference standard, the diagnostic performances of both methods were analyzed by the area under the receiver operating characteristic curve (AUC). Arthroscopy confirmed 165 SSP-ISP tendon tears and 103 SSC tendon tears. For diagnosing SSP-ISP tendon tears, the AUC values were 0.964 and 0.989 for the 2D sequences and 3D T1-weighted FSE sequence, respectively, in reader I and 0.947 and 0.963, respectively, in reader II. The AUC values for diagnosing SSC tendon tears were 0.921 and 0.925, respectively, for reader I and 0.856 and 0.860, respectively, for reader II. There was no significant difference between the AUC values of the 2D and 3D sequences in either reader for either type of tear. 3D indirect isotropic MR arthrography with FSE sequence and the conventional 2D arthrography are not significantly different in terms of accuracy for diagnosing rotator cuff tears.

  18. Comparison of three dimensional isotropic and two dimensional conventional indirect MR arthrography for the diagnosis of rotator cuff tears

    International Nuclear Information System (INIS)

    Lee, Ji Hyun; Yoon, Young Cheol; Kwon, Jong Won; Yoo, Jae Chul; Cha, Jang Kyu; Jee, Suk Kyoung

    2014-01-01

    To compare the accuracy between a three-dimensional (3D) indirect isotropic T1-weighted fast spin-echo (FSE) magnetic resonance (MR) arthrography and a conventional two-dimensional (2D) T1-weighted sequences of indirect MR arthrography for diagnosing rotator cuff tears. The study was approved by our Institutional Review Board. In total, 205 patients who had undergone indirect shoulder MR arthrography followed by arthroscopic surgery for 206 shoulders were included in this study. Both conventional 2D T1-weighted FSE sequences and 3D isotropic T1-weighted FSE sequence were performed in all patients. Two radiologists evaluated the images for the presence of full- or partial-thickness tears in the supraspinatus-infraspinatus (SSP-ISP) tendons and tears in the subscapularis (SSC) tendons. Using the arthroscopic findings as the reference standard, the diagnostic performances of both methods were analyzed by the area under the receiver operating characteristic curve (AUC). Arthroscopy confirmed 165 SSP-ISP tendon tears and 103 SSC tendon tears. For diagnosing SSP-ISP tendon tears, the AUC values were 0.964 and 0.989 for the 2D sequences and 3D T1-weighted FSE sequence, respectively, in reader I and 0.947 and 0.963, respectively, in reader II. The AUC values for diagnosing SSC tendon tears were 0.921 and 0.925, respectively, for reader I and 0.856 and 0.860, respectively, for reader II. There was no significant difference between the AUC values of the 2D and 3D sequences in either reader for either type of tear. 3D indirect isotropic MR arthrography with FSE sequence and the conventional 2D arthrography are not significantly different in terms of accuracy for diagnosing rotator cuff tears.

  19. Arthrography

    Medline Plus

    Full Text Available ... top of page How should I prepare? No special preparation is necessary before direct arthrography. Food and fluid intake do not need to be restricted, unless a sedative will be ...

  20. CT arthrography and virtual arthroscopy in the diagnosis of the anterior cruciate ligament and meniscal abnormalities of the knee joint

    International Nuclear Information System (INIS)

    Lee, Whal; Chung, Jin-Wook; Kang, Heung-Sik; Hong, Sung-Hwan; Choi, Ja-Young; Kim, Ho-Sung; Kim, Seok-Jung; Kim, Hyung-Ho

    2004-01-01

    To determine the diagnostic accuracy of CT arthrography and virtual arthroscopy in the diagnosis of anterior cruciate ligament and meniscus pathology. Thirty-eight consecutive patients sho underwent CT arthrography and arthroscopy of the knee were included in this study. The ages of the patients ranged from 19 to 52 years and all of the patients were male. Sagittal, coronal, transverse and oblique coronal multiplanar reconstruction images were reformatted from CT arthrography. Virtual arthroscopy was performed from 6 standard views using a volume rendering technique. Three radiologists analyzed the MPR images and two orthopedic surgeons analyzed the virtual arthroscopic images. The sensitivity and specificity of CT arthrography for the diagnosis of anterior cruciate ligament abnormalities were 87.5%-100% and 93.3%-96.7%, respectively and those for meniscus abnormalities were 91.7%-100% and 98.1%, respectively. The sensitivity and specificity of virtual arthroscopy for the diagnosis of anterior cruciate ligament abnormalities were 87.5% and 83.3%-90%, respectively, and those for meniscus abnormalities were 83.3%-87.5% and 96.1-98.1%, respectively. CT arthrography and virtual arthroscopy showed good diagnostic accuracy for anterior cruciate ligament and meniscal abnormalities

  1. Abduction and external rotation (ABER) MR arthrography of the shoulder. Benefits and limitations

    International Nuclear Information System (INIS)

    Mostafa, A.; Gokan, Takehiko; Munechika, Hirotsugu; Ogawa, Takashi; El-Feky, A.A.

    2001-01-01

    The purpose of this study was to show the benefits and limitations of using abduction and external rotation (ABER) positions of the arm during MR arthrography of the shoulder in the evaluation of the rotator-cuff tendon, the capsulolabral complex and the shoulder joint after surgery. Forty-seven patients complaining of either shoulder instability, chronic shoulder pain, pain of unknown cause or pain following shoulder surgery were studied using the direct MR arthrography technique in both the standard neutral position with the arm adducted as well as with the arm in the ABER position. A correlation was obtained between the MR arthrography findings and the surgical findings in 10 reports and clinical presentations of the examined patients. Three patients [6%] were unable to perform ABER positioning. ABER oblique axial images were better than standard oblique coronal images in revealing undersurface tears of the rotator cuff particularly of the grade I type. Four tears were missed in standard images. Oblique axial images were better than standard axial images in demonstrating non-displaced anterior labral tears. One tear was missed and two tears were suspected in the standard images. Oblique axial images were less sensitive than oblique coronal images in the diagnosis of superior labral tears. Two tears were missed in ABER images. The ABER oblique axial MR arthrogram is a useful adjunct to the standard axial and oblique coronal MR arthrograms for assessment of capsulolabral abnormalities and rotator-cuff tendon tears despite some limitations. (author)

  2. Arthrography

    Medline Plus

    Full Text Available ... felt to be inadequate in assessing a joint abnormality. There are several methods to perform direct arthrography. ... The procedure is most often used to identify abnormalities within the: shoulder elbow wrist hip knee ankle ...

  3. Arthrography

    Medline Plus

    Full Text Available ... CT arthrography and have claustrophobia (fear of enclosed spaces) or anxiety, you may want to ask your ... and sometimes air are injected into the joint space while the radiologist observes with fluoroscopy or ultrasound. ...

  4. Arthrography

    Medline Plus

    Full Text Available ... preparation is necessary before direct arthrography. Food and fluid intake do not need to be restricted, unless ... a syringe to drain (or aspirate) the joint fluid, which may be sent to a laboratory for ...

  5. Arthrography

    Medline Plus

    Full Text Available ... by the interpreting radiologist. Frequently, the differentiation of abnormal (diseased) tissue from normal tissues is better with ... Benefits Direct arthrography is particularly effective for detecting disease of the structures within the joints such as ...

  6. Arthrography

    Medline Plus

    Full Text Available ... others nearby harm. These items include: jewelry, watches, credit cards and hearing aids, all of which can ... top of page What are the benefits vs. risks? Benefits Direct arthrography is particularly effective for detecting ...

  7. Arthrography

    Medline Plus

    Full Text Available ... have MR or CT arthrography and have claustrophobia (fear of enclosed spaces) or anxiety, you may want ... physician and technologist if they may be pregnant. Children younger than 13 may need to be sedated ...

  8. Arthrography

    Medline Plus

    Full Text Available ... No special preparation is necessary before direct arthrography. Food and fluid intake do not need to be ... to iodine or x-ray contrast material, drugs, food, or environmental agents. However, the contrast material used ...

  9. Arthrography

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Direct arthrography is particularly effective for detecting ... used for conventional x-rays and CT scanning. Risks Any procedure where the skin is penetrated carries ...

  10. Arthrography

    Medline Plus

    Full Text Available ... of the body to a small dose of ionizing radiation to produce pictures of the inside of ... or copied to CD. MRI does not use ionizing radiation (x-rays). CT direct arthrography uses the ...

  11. Arthrography of the ankle sprains

    International Nuclear Information System (INIS)

    Han, Moon Hee

    1985-01-01

    Ankle arthrography, by direct puncture of joint cavity, is considered to be a simple and accurate diagnostic method for a precise evaluation of ligamentous injury. Forty-seven cases of ankle arthrography were successively performed in the patients of acute ankle sprains. The purpose of this study is to demonstrate how ankle arthrography can delineate the pathologic anatomy in such cases. The results are as follows: 1. Thirty cases among forty seven revealed the findings of ligament tears. 2. For better diagnostic accuracy, the arthrography should be performed within 72 hrs. after injury. 3. The anterior talofibular ligament tears were the most common (twenty-nine cases) of all and seventeen of them revealed tears without association of any other ligament tears. 4. There were ten cases of calcaneofibular ligament tears and nine of them were associated with anterior talofibular ligament tears. 5. Three cases of anterior tibiofibular and one deltoid ligament tears were demonstrated

  12. Dual joint space arthrography in temporomandibular joint disorders: Comparison with single inferior joint space arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hyung Sik; Chang, Duk Soo; Lee, Kyung Soo; Kim, Woo Sun; Sung, Jung Ho; Jun, Young Hwan [Capital Armed Forces General Hospital, Seoul (Korea, Republic of)

    1989-02-15

    The temporomandibular joint(TMJ) is really a complex of two synovial space separated by fibrocartilaginous disc. Single inferior joint space arthrography is commonly performed for evaluation of TMJ disorders, which is known to be superior in demonstrating joint dynamics. But it reveals only the inferior surface of the disc. Therefore, dual space arthrography is superior to demonstrate the soft tissue anatomic feature of the joint such as disc position and shape. Authors performed 83 TMJ arthrograms in TMJ problems. Initially, the inferior joint space was done and then the superior space was sequentially contrasted. The follow results were noted: 1. In all cases, dual space arthrography revealed accurate disc shape and positions. 2. Concordant findings between the two techniques: 68 cases (82%). Discordance between the two techniques: 15 cases (18%) 3. Possible causes of discordance between inferior and dual space arthrography. a) Normal varians of anterior recess: 3 cases b) Posterior disc displacement: 4 cases c) Influence of the patient's head position change :4 cases d) False perforation: 2 cases e) Reduction change: 2 cases 4. In 5 cases with anterior displacement, dual space arthrography gave additional findings such as adhesion within the superior space, which could not be evaluated by single inferior space.

  13. MR imaging of rotator cuff tears

    International Nuclear Information System (INIS)

    Kumagai, Hideo

    1992-01-01

    A total of 115 patients with clinical symptoms and signs suggesting rotator cuff tears underwent MR imaging with a 1.5-Tesla system. The body coil was used as the receiver coil in 24 patients and a single 10 cm surface coil in 91. Arthrography or MR imaging with intra-articular Gd-DTPA (MR arthrography) was performed in 95 of the 115. T2-weighted images with the body coil showed high signal intensity lesions in rotator cuffs in only seven of the 10 patients who had tears demonstrated by arthrography or MR arthrography. On the other hand, T2-weighted images with the surface coil demonstrated high signal intensity lesions in cuffs in all 27 patients who were diagnosed to have tears by arthrography or MR arthrography. In 12 patietns, T2-wighted images with the surface coil showed high signal intensity lesions in cuffs, while arthrography and MR arthrography did not show tears. Surgery was performed in four of the 12 patients and partial tears were confirmed. A single 10 cm surface coil, 3 mm slice thickness and 2.5 second repetition time seem to account for the fine visualization of cuff tears by the T2-weighted images. These results suggest that T2-weighted images obtained with the surface coil are superior to arthrography and MR arthrography. (author)

  14. Arthrography

    Medline Plus

    Full Text Available ... Videos related to Direct Arthrography Sponsored by Please note RadiologyInfo.org is not a medical facility. Please ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  15. A comparison of magnetic resonance arthrography and arthroscopic findings in the assessment of anterior shoulder dislocations

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, R.W.; Naeem, R.; Srinivas, K.; Shyamalan, G. [Birmingham Heartlands Hospital, Birmingham (United Kingdom)

    2015-05-01

    The aim of this study is to establish the sensitivity and specificity of MRA in the investigation of patients with traumatic anterior shoulder dislocations. A retrospective analysis of consecutive patients undergoing both magnetic resonance arthrography and arthroscopic assessment after a traumatic anterior shoulder dislocation between January 2011 and 2014 was performed. Demographic data were collected from electronic records. Images were interpreted by 8 musculoskeletal radiologists and patients were treated by 8 consultant orthopaedic surgeons. Arthroscopic findings were obtained from surgical notes and these findings were used as a reference for MRA. The sensitivity, specificity, and positive predictive value were calculated for the different injuries. Sixty-nine patients underwent both an MRA and shoulder arthroscopy during the study period; however, clinical notes were unavailable in 9 patients. Fifty-three patients (88 %) were male, the mean age was 28 years (range 18 to 50) and 16 subjects (27 %) had suffered a primary dislocation. The overall sensitivity and specificity of MRA to all associated injuries was 0.9 (CI 0.83-0.95) and 0.94 (CI 0.9-0.96) retrospectively. The lowest sensitivity was seen in osseous Bankart 0.8 (CI 0.44-0.96) and superior labral tear (SLAP) lesions 0.5 (CI 0.14-0.86). The overall positive predictive value was 0.88 (CI 0.76-0.91) with the lowest values found in rotator cuff 0.4 (CI 0.07-0.83) and glenohumeral ligament (GHL) lesions 0.29 (CI 0.05-0.7). Magnetic resonance angiography has a high sensitivity when used to identify associated injuries in shoulder dislocation, although in 8 patients (13 %) arthroscopy identified an additional injury. The overall agreement between MRA and arthroscopic findings was good, but the identification of GHL and rotator cuff injuries was poor. (orig.)

  16. A comparison of magnetic resonance arthrography and arthroscopic findings in the assessment of anterior shoulder dislocations

    International Nuclear Information System (INIS)

    Jordan, R.W.; Naeem, R.; Srinivas, K.; Shyamalan, G.

    2015-01-01

    The aim of this study is to establish the sensitivity and specificity of MRA in the investigation of patients with traumatic anterior shoulder dislocations. A retrospective analysis of consecutive patients undergoing both magnetic resonance arthrography and arthroscopic assessment after a traumatic anterior shoulder dislocation between January 2011 and 2014 was performed. Demographic data were collected from electronic records. Images were interpreted by 8 musculoskeletal radiologists and patients were treated by 8 consultant orthopaedic surgeons. Arthroscopic findings were obtained from surgical notes and these findings were used as a reference for MRA. The sensitivity, specificity, and positive predictive value were calculated for the different injuries. Sixty-nine patients underwent both an MRA and shoulder arthroscopy during the study period; however, clinical notes were unavailable in 9 patients. Fifty-three patients (88 %) were male, the mean age was 28 years (range 18 to 50) and 16 subjects (27 %) had suffered a primary dislocation. The overall sensitivity and specificity of MRA to all associated injuries was 0.9 (CI 0.83-0.95) and 0.94 (CI 0.9-0.96) retrospectively. The lowest sensitivity was seen in osseous Bankart 0.8 (CI 0.44-0.96) and superior labral tear (SLAP) lesions 0.5 (CI 0.14-0.86). The overall positive predictive value was 0.88 (CI 0.76-0.91) with the lowest values found in rotator cuff 0.4 (CI 0.07-0.83) and glenohumeral ligament (GHL) lesions 0.29 (CI 0.05-0.7). Magnetic resonance angiography has a high sensitivity when used to identify associated injuries in shoulder dislocation, although in 8 patients (13 %) arthroscopy identified an additional injury. The overall agreement between MRA and arthroscopic findings was good, but the identification of GHL and rotator cuff injuries was poor. (orig.)

  17. Arthrography

    Medline Plus

    Full Text Available ... of the body to a small dose of ionizing radiation to produce pictures of the inside of the ... or copied to CD. MRI does not use ionizing radiation (x-rays). CT direct arthrography uses the same ...

  18. Diagnosis of SLAP lesions with Grashey-view arthrography

    International Nuclear Information System (INIS)

    Lee, J.H. Edmund; Van Raalte, Vanessa; Malian, Vartan

    2003-01-01

    To examine the accuracy of Grashey views obtained during shoulder arthrography in the diagnosis of clinically relevant superior labrum anterior-posterior (SLAP) lesions. Grashey views obtained during diagnostic arthrography (conventional and MR) were used to examine the superior labrum. Twenty-eight of 118 shoulder arthrograms obtained during a 27-month period fulfilled study criteria and were correlated for accuracy using arthroscopically confirmed grade 2-4 SLAP lesions as the standard of reference. Arthrograms were graded using the consensus method. Prevalence, sensitivity, specificity, and accuracy were 21%, 50%, 86%, and 79%. The appearance of the superior labrum on the Grashey view was compared subjectively with MR arthrography. Sources of errors were analyzed. Grashey views obtained during shoulder arthrography can diagnose clinically relevant SLAP lesions with moderately high specificity, moderate accuracy, and limited sensitivity. Findings on the Grashey view closely resemble those seen on coronal oblique MR arthrography. Grashey views should be considered in patients undergoing shoulder arthrography. (orig.)

  19. Diagnosis of SLAP lesions with Grashey-view arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J.H. Edmund [Radiological Associates of Sacramento Medical Group, Inc., 1500 Expo Parkway, Sacramento, CA 95815 (United States); Department of Diagnostic Radiology, UC Davis Medical Center, 4860 Y Street, Suite 3100, Sacramento, CA 95817 (United States); Van Raalte, Vanessa; Malian, Vartan [Department of Diagnostic Radiology, UC Davis Medical Center, 4860 Y Street, Suite 3100, Sacramento, CA 95817 (United States)

    2003-07-01

    To examine the accuracy of Grashey views obtained during shoulder arthrography in the diagnosis of clinically relevant superior labrum anterior-posterior (SLAP) lesions. Grashey views obtained during diagnostic arthrography (conventional and MR) were used to examine the superior labrum. Twenty-eight of 118 shoulder arthrograms obtained during a 27-month period fulfilled study criteria and were correlated for accuracy using arthroscopically confirmed grade 2-4 SLAP lesions as the standard of reference. Arthrograms were graded using the consensus method. Prevalence, sensitivity, specificity, and accuracy were 21%, 50%, 86%, and 79%. The appearance of the superior labrum on the Grashey view was compared subjectively with MR arthrography. Sources of errors were analyzed. Grashey views obtained during shoulder arthrography can diagnose clinically relevant SLAP lesions with moderately high specificity, moderate accuracy, and limited sensitivity. Findings on the Grashey view closely resemble those seen on coronal oblique MR arthrography. Grashey views should be considered in patients undergoing shoulder arthrography. (orig.)

  20. Arthrography

    Medline Plus

    Full Text Available ... copied to CD. MRI does not use ionizing radiation (x-rays). CT direct arthrography uses the same type ... remains in a patient's body after an x-ray examination. X-rays usually have no side effects in the ...

  1. Arthrography

    Medline Plus

    Full Text Available ... your procedure. top of page What does the equipment look like? The equipment typically used for this examination consists of a ... in a separate room from the scanner. Other equipment necessary for performing arthrography include a variety of ...

  2. Arthrography

    Medline Plus

    Full Text Available ... to Direct Arthrography Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ... links: For the convenience of our users, RadiologyInfo .org provides links to relevant websites. RadiologyInfo.org , ACR ...

  3. Arthrography

    Medline Plus

    Full Text Available ... over time. top of page What are the benefits vs. risks? Benefits Direct arthrography is particularly effective for detecting disease ... cancer from excessive exposure to radiation. However, the benefit of an accurate diagnosis far outweighs the risk. ...

  4. Arthrography

    Medline Plus

    Full Text Available ... may help your physician determine the cause of chronic joint pain and what therapies may be effective. ... Benefits Direct arthrography is particularly effective for detecting disease ... Any procedure where the skin is penetrated carries a risk of infection. The ...

  5. MR imaging of hyaline cartilage in chondromalacia patellae and osteochondrosis dissecans: A comparison with CT-arthrography and arthroscopy

    International Nuclear Information System (INIS)

    Lehner, K.; Heuck, A.; Lukas, P.; Rodammer, G.; Allgayer, B.; Pasquay, E.

    1987-01-01

    Superior to spin-echo sequences, the articular hyaline cartilage was imaged with fast-field-echo sequences (FFE, Gyroscan 0.5-T, Philips) with an excitation pulse angle of 40 0 to 60 0 . Chondromalaceous lesions could be demonstrated in 30 patients with chondropathia patellae with the same sensitivity compared with CT arthrography. In a further 50 patients with osteochondrosis dissecans, discontinuities of the cartilage could be predicted using the deeply invading articular fluid as an indicator. The sensitivity of MR imaging, as controlled by arthroscopy, was very high in that respect. Separate from the nonhemorrhagic articular fluid, the cartilaginous defects could be imaged directly by variation of the FFE parameters

  6. Arthrography

    Medline Plus

    Full Text Available ... be asked to wear a gown. What is Direct Arthrography? What are some common uses of the procedure? How should I prepare? What does the equipment look like? How does the procedure work? How is the procedure performed? What will I ...

  7. Anterior labral tear: diagnostic value of MR arthrography of the shoulder

    International Nuclear Information System (INIS)

    Ryu, Jung Kyu; Yoon, Yeong Cheol; Ryu, Kyung Nam; Rhee, Yong Girl

    2001-01-01

    To assess the accuracy of magnetic resonance(MR) arthrography in the diagnosis of anterior labral tear of the shoulder Between september 1996 and February 2000, MR arthrography of the shoulder was performed in 281 patients with a history of shoulder pain or instability. Among this total, only 157 shoulders in 154 patients who underwent arthroscopy or open surgery 0 to 230 (average, 20.9) days after MR arthrography were included in this study; the subjects comprised of 150 males and 4 females with an average age of 23.3 years. MR arthrographs of these 154 patients were analyzed for the presence of anterior labral tears, and the findings were correlated with the arthroscopic and surgical findings. Anterior labral tear was classified as A to D according to its location, as determined by arthroscopy and surgery. (A=4 to 6 o'clock direction, anteroinferior; B=2 to 4 o'clock direction, central; C=12 to 2 o'clock direction, anterosuperior; D= SLAP lesion). The retrospective analysis of MR arthrographs showing false-positive and negative findings was also underthken.. In the diagnosis of anterior labral tear, MR arthrography showed a sensitivity of 94%, a specificity of 90% and an accuracy of 91%. Anterior labral tears were confirmed by arthroscopy or surgery in 62 of the 157 shoulders (39%). Among 62 lesion, two (3%) were observed in area A, 32(52%) in area A+B, nine (15%) in area A+B+C, one(2%) in area A+B+D,13(21%) in area A+B+C+D, two (3%) in area B+C, one(2%) in area B+D, and two(3%) in area C. Among ten false-positive cases, seven were focal lessions (two, three and two lesions in area A, B and C, respectively), and in the remaining three cases, lacated in area A+B, MR arthrography revealed thickening and deformation. All four false negatives were focal lesions (two in area A and two in area C). Other than in focal lesions, in which accuracy was relatively low, MR arthrography showed high sensitivity, specificity and accuracy in the diagnosis of anterior labral tear

  8. Anterior approach for knee arthrography

    International Nuclear Information System (INIS)

    Zurlo, J.V.; Towers, J.D.; Golla, S.

    2001-01-01

    Objective. To develop a new method of magnetic resonance arthrography (MRA) of the knee using an anterior approach analogous to the portals used for knee arthroscopy.Design. An anterior approach to the knee joint was devised mimicking anterior portals used for knee arthroscopy. Seven patients scheduled for routine knee MRA were placed in a decubitus position and under fluoroscopic guidance a needle was advanced from a position adjacent to the patellar tendon into the knee joint. After confirmation of the needle tip location, a dilute gadolinium solution was injected.Results and conclusion. All the arthrograms were technically successful. The anterior approach to knee MRA has greater technical ease than the traditional approach with little patient discomfort. (orig.)

  9. Texture analysis of torn rotator cuff on preoperative magnetic resonance arthrography as a predictor of postoperative tendon status

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Yeon Ah; Lee, Guen Young; Lee, Joon Woo; Lee, Eugene; Kim, Boh Young; Kim, Su Jin; Ahn, Joong Mo; Kang, Heung Sik [Dept. of Radiology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2017-08-01

    To evaluate texture data of the torn supraspinatus tendon (SST) on preoperative T2-weighted magnetic resonance arthrography (MRA) using the gray-level co-occurrence matrix (GLCM) for prediction of post-operative tendon state. Fifty patients who underwent arthroscopic rotator cuff repair for full-thickness tears of the SST were included in this retrospective study. Based on 1-year follow-up, magnetic resonance imaging showed that 30 patients had intact SSTs, and 20 had rotator cuff retears. Using GLCM, two radiologists measured independently the highest signal intensity area of the distal end of the torn SST on preoperative T2-weighted MRA, which were compared between two groups.The relationships with other well-known prognostic factors, including age, tear size (anteroposterior dimension), retraction size (mediolateral tear length), grade of fatty degeneration of the SST and infraspinatus tendon, and arthroscopic fixation technique (single or double row), also were evaluated. Of all the GLCM features, the retear group showed significantly higher entropy (p < 0.001 and p = 0.001), variance (p = 0.030 and 0.011), and contrast (p = 0.033 and 0.012), but lower angular second moment (p < 0.001 and p = 0.002) and inverse difference moment (p = 0.027 and 0.027), as well as larger tear size (p = 0.001) and retraction size (p = 0.002) than the intact group. Retraction size (odds ratio [OR] = 3.053) and entropy (OR = 17.095) were significant predictors. Texture analysis of torn SSTs on preoperative T2-weighted MRA using the GLCM may be helpful to predict postoperative tendon state after rotator cuff repair.

  10. Texture analysis of torn rotator cuff on preoperative magnetic resonance arthrography as a predictor of postoperative tendon status

    International Nuclear Information System (INIS)

    Kang, Yeon Ah; Lee, Guen Young; Lee, Joon Woo; Lee, Eugene; Kim, Boh Young; Kim, Su Jin; Ahn, Joong Mo; Kang, Heung Sik

    2017-01-01

    To evaluate texture data of the torn supraspinatus tendon (SST) on preoperative T2-weighted magnetic resonance arthrography (MRA) using the gray-level co-occurrence matrix (GLCM) for prediction of post-operative tendon state. Fifty patients who underwent arthroscopic rotator cuff repair for full-thickness tears of the SST were included in this retrospective study. Based on 1-year follow-up, magnetic resonance imaging showed that 30 patients had intact SSTs, and 20 had rotator cuff retears. Using GLCM, two radiologists measured independently the highest signal intensity area of the distal end of the torn SST on preoperative T2-weighted MRA, which were compared between two groups.The relationships with other well-known prognostic factors, including age, tear size (anteroposterior dimension), retraction size (mediolateral tear length), grade of fatty degeneration of the SST and infraspinatus tendon, and arthroscopic fixation technique (single or double row), also were evaluated. Of all the GLCM features, the retear group showed significantly higher entropy (p < 0.001 and p = 0.001), variance (p = 0.030 and 0.011), and contrast (p = 0.033 and 0.012), but lower angular second moment (p < 0.001 and p = 0.002) and inverse difference moment (p = 0.027 and 0.027), as well as larger tear size (p = 0.001) and retraction size (p = 0.002) than the intact group. Retraction size (odds ratio [OR] = 3.053) and entropy (OR = 17.095) were significant predictors. Texture analysis of torn SSTs on preoperative T2-weighted MRA using the GLCM may be helpful to predict postoperative tendon state after rotator cuff repair

  11. Arthrography

    Medline Plus

    Full Text Available ... related pain or inflammation and provide physicians additional information about possible sources of pain. top of page How should I prepare? No special preparation is necessary before direct arthrography. Food and fluid intake do not need to be restricted, unless a sedative will be ...

  12. Magnetic resonance arthrography in chronic wrist pain. Artografia con Risonanza Magnetica (arto-RM) nelle malattie dolorose croniche del polso

    Energy Technology Data Exchange (ETDEWEB)

    Valeri, G.; Ferrara, C. (Ancona Univ. (Italy). Cattedra di Radiologia); Carloni, S. (Ancona Univ. (Italy). Cattedra di Ortopedia) (and others)

    The purpose of this paper is to investigate the clinical role of Magnetic Resonance Arthrography (MRA) of the wrist in subjects with chronic pain. Thirty-five patients complaining of wrist pain for more than 6 months were submitted to MRI an MRA. All patients received and intra-articular injection of 2-10 mL of a 10 mmol saline solution of Gd-DPTA. The overall diagnostic accuracy rates of MRI and MRA were 40% and 81% respectively, with sensitivity and specificity of 63% and 39% (MRI) and of 82% and 79% (MRA). The conclusion is that compared with MRI, MRA can be considered a useful tool for the visualization of interosseus carpal ligaments and of the triangular fibrocartilage complex. MRA also helps detect injuries in these structures.

  13. Arthrography of the ankle

    International Nuclear Information System (INIS)

    Lindholmer, E.; Foged, N.; Jensen, J. Th.

    1978-01-01

    Arthrography was performed in 105 cases with freshly sprained ankles and signs of rupture of the anterior talofibular ligament. They were subsequently operated upon. The arthrographic films were examined retrospectively to assess the value of different criteria for the differential diagnosis between rupture of the anterior talofibular ligament and combined rupture of this and the calcaneofibular ligament. The diagnostic value of arthrography was found to be high in isolated rupture of the anterior talofibular ligament, and is acceptable in the combined ruptures. (Auth.)

  14. Chronic ankle instability: evaluation with stress radiography, CT and CT arthrography

    International Nuclear Information System (INIS)

    Faure, Ch.; Deplus, F.; Bochu, M.; Besse, J.L.; Moyen, B.

    1997-01-01

    We retrospectively evaluated the anterior talo-fibular ligament and the tarsal sinus of 17 patients who had complained of chronic ankle external instability. This study based on both surgery and CT-arthrography findings shows the pathologic or normal aspects of the talo-fibular anterior ligament (normal, lax, fibrosis residue, ruptured). It confirms the good anatomic analysis of the tarsal sinus, i particular the anterior talo-calcaneal interosseous ligament and the search for fibrosis. We underline that capsular distension due to subtalar laxity is not detected with medical imaging. Compared with surgery (all patients), CT arthrography demonstrated the different aspects of the anterior talo fibular ligament injuries (normal, lax, discontinuous). (authors)

  15. 3.0 T conventional hip MR and hip MR arthrography for the acetabular labral tears confirmed by arthroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Chun-Yan [Department of Radiology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing 100191 (China); Wang, Jian-Quan [Department of Sports Medicine, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing 100191,PR China (China); Zheng, Zhuo-Zhao, E-mail: zzhuozhao@aliyun.com [Department of Radiology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing 100191 (China); Ren, A.-Hong [Department of Radiology, Beijing Daxing Hospital, 26 West Huangcun Road, Daxing District, Beijing 102600 (China)

    2014-10-15

    Highlights: • MR is the preferred imaging modality for diagnosing acetabular labral tears. • The diagnostic performance of MR arthrography are superior than conventional hip MR. • The hip MR arthrography is recommended for diagnosing acetabular labral lesions. - Abstract: Objective: To evaluate the value of hip MR for diagnosing acetabular labrum tears, and to further compare the diagnostic performances of conventional MR with MR arthrography in acetabular labrum tears. Methods: 90 patients undergoing both hip MR examination and subsequent hip arthroscopy were retrospectively evaluated. Of these patients, 34 accepted both conventional MR and MR arthrography; while the other 56 only underwent conventional MR examination. All hip MR images were independently reviewed by two radiologists, and further compared with the results of hip arthroscopy. Results: 59 of 90 patients were confirmed with acetabular labral tears by hip arthroscopy and 31 without tears. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of conventional MR for evaluating the acetabular labral tears were 61.0%, 77.4%, 83.7% and 51.1% (radiologist A), and 66.1%, 74.2%, 82.9% and 53.4% (radiologist B), respectively, with good consistency between the two observers (K = 0.645). The sensitivity, specificity, PPV and NPV of MR arthrography for assessing the acetabular labral tears were 90.5%, 84.6%, 90.5% and 84.6% (radiologist A), and 95.2%, 84.6%, 90.9% and 91.7% (radiologist B), respectively, with excellent good consistency between the two observers (K = 0.810). The sensitivity and NPV of MR arthrography for diagnosing the acetabular labral tears were significantly higher than those of conventional MR (both P < 0.05). Conclusion: Hip MR arthrography is a reliable evaluation modality for diagnosing the acetabular labral tears, and its diagnostic performance is superior to that of conventional MR at 3.0 T.

  16. Arthrography of the ankle joint

    International Nuclear Information System (INIS)

    Crespi Porro, R.; Zellner, A.; Puricelli, G.; Quaglia, R.; Chelazzi, G.

    1984-01-01

    Arthrography of the ankle joint was first carried out by Johnson and Palmer at the Military Hospital in Stockholm in 1940. Arthrography can be used for judging the integrity of the articular cartilage, of osteochondritis dissecans, arthritis or adhesive capsulitis. The literature shows, however, that more than 95% of the patients on whom this examination has been performed has suffered from acute trauma. (orig.) [de

  17. Arthrography of the biceps tendon

    International Nuclear Information System (INIS)

    Ahovuo, J.; Linden, H.; Hovi, I.; Paavolainen, P.; Bjoerkenheim, J.M.

    1988-01-01

    The purpose of this study was to analyse the factors having an influence on the arthrographic imaging of the biceps tendon. The study comprised 174 patients suffering from chronic shoulder pain. They underwent conventional shoulder arthrography with sodium meglumine metrizoate or metrizamide as a contrast medium. In the patients with a full-thickness tear of the rotator cuff, the biceps tendon sheath failed to fill with contrast medium more often than in those with an intact tendinous cuff. Metrizamide filled the biceps tendon sheath more readily than sodium meglumine metrizoate in patients with a full-thickness tear of the ortator cuff. The volume of the contrast medium injected had no influence on the imaging of the biceps tendon. (orig.)

  18. Indirect magnetic resonance arthrography of the shoulder; a reliable diagnostic tool for investigation of suspected labral pathology

    Energy Technology Data Exchange (ETDEWEB)

    Fallahi, Farshid [North Cumbria University Hospitals NHS Trust, Carlisle (United Kingdom); North Cumbria University Hospitals, Department of Radiology, Carlisle (United Kingdom); Green, Nick; Gadde, Sarat; Jeavons, Lisa; Armstrong, Patrick; Jonker, Leon [North Cumbria University Hospitals NHS Trust, Carlisle (United Kingdom)

    2013-09-15

    Indirect magnetic resonance arthrography (I-MRA) confers significant logistical advantages over direct MRA and does not require articular injection. In this study, we determined the diagnostic performance of I-MRA in relation to conventional MRI and arthroscopy or surgery in detecting tears of the glenoid labrum, including Bankart lesions and superior labral antero-posterior (SLAP) tears in a standard clinical setting. Ninety-one symptomatic patients underwent conventional MRI and I-MRA of the affected shoulder, followed by either arthroscopy or open surgery. The scans were interpreted independently by two experienced radiology consultants with a special interest in musculoskeletal radiology. Using the surgical findings as the standard of reference, sensitivity, specificity, and diagnostic accuracy of conventional non-contrast MRI and I-MRA in the detection of labral tears were calculated. The sensitivity of I-MRA was 95 and 97 %, respectively, for two radiologists as opposed to 79 and 83 % for conventional MRI. For both radiologists, the specificity of I-MRA, as well as MRI, was 91 % for detection of labral tears of all types. Accuracy of diagnosis was 93 and 95 %, respectively, for two radiologists with indirect MRA, compared to 84 and 86 % with non-contrast MRI. This retrospective study shows that I-MRA is a highly accurate and sensitive method for the detection of labral tears. The data obtained supports the use of I-MRA as standard practice in patients with shoulder instability due to suspected labral pathology where further investigative imaging is indicated. (orig.)

  19. Indirect magnetic resonance arthrography of the shoulder; a reliable diagnostic tool for investigation of suspected labral pathology

    International Nuclear Information System (INIS)

    Fallahi, Farshid; Green, Nick; Gadde, Sarat; Jeavons, Lisa; Armstrong, Patrick; Jonker, Leon

    2013-01-01

    Indirect magnetic resonance arthrography (I-MRA) confers significant logistical advantages over direct MRA and does not require articular injection. In this study, we determined the diagnostic performance of I-MRA in relation to conventional MRI and arthroscopy or surgery in detecting tears of the glenoid labrum, including Bankart lesions and superior labral antero-posterior (SLAP) tears in a standard clinical setting. Ninety-one symptomatic patients underwent conventional MRI and I-MRA of the affected shoulder, followed by either arthroscopy or open surgery. The scans were interpreted independently by two experienced radiology consultants with a special interest in musculoskeletal radiology. Using the surgical findings as the standard of reference, sensitivity, specificity, and diagnostic accuracy of conventional non-contrast MRI and I-MRA in the detection of labral tears were calculated. The sensitivity of I-MRA was 95 and 97 %, respectively, for two radiologists as opposed to 79 and 83 % for conventional MRI. For both radiologists, the specificity of I-MRA, as well as MRI, was 91 % for detection of labral tears of all types. Accuracy of diagnosis was 93 and 95 %, respectively, for two radiologists with indirect MRA, compared to 84 and 86 % with non-contrast MRI. This retrospective study shows that I-MRA is a highly accurate and sensitive method for the detection of labral tears. The data obtained supports the use of I-MRA as standard practice in patients with shoulder instability due to suspected labral pathology where further investigative imaging is indicated. (orig.)

  20. Indirect MR-arthrography in osteochondral autograft and crushed bone graft with a collagen membrane-Correlation with histology

    Energy Technology Data Exchange (ETDEWEB)

    Streitparth, F. [Klinik fuer Strahlenheilkunde, Charite, Campus Virchow-Klinikum, Humboldt-University, Berlin (Germany)], E-mail: florian.streitparth@charite.de; Schoettle, P.; Schell, H. [Center for Musculoskeletal Surgery, Charite, Campus Virchow-Klinikum, Humboldt-University, Berlin (Germany); Lehmkuhl, L.; Madej, T.; Wieners, G. [Klinik fuer Strahlenheilkunde, Charite, Campus Virchow-Klinikum, Humboldt-University, Berlin (Germany); Duda, G.N. [Center for Musculoskeletal Surgery, Charite, Campus Virchow-Klinikum, Humboldt-University, Berlin (Germany); Schroeder, R.J. [Klinik fuer Strahlenheilkunde, Charite, Campus Virchow-Klinikum, Humboldt-University, Berlin (Germany)

    2009-04-15

    Objective: To analyze the spectrum of findings in indirect MR-arthrography following osteochondral autograft transfer system (OATS) and crushed bone graft using a magnetic resonance imaging (MRI) scoring and grading system in relation to histology as the standard of reference. Materials and methods: Iatrogenic lesions were set at ovine condylar facets (n = 6/group), treated with OATS or crushed bone graft. 1.5 T MRI was performed 6 months after surgery using PD-weighted (w fat saturated (fs) fast spin echo (FSE), T1-w 2D, and 3D fs gradient echo (GE) sequences 30 min. after i.v. Gd-DTPA administration and passive joint exercise. The repair tissue was evaluated by two independent radiologists. The MR findings were compared to histology. Results: In all cases, MRI and histologic grading correlated well and showed significant superior repair in OATS at 6 months (p < 0.05), reproducing the original articular contour and a good subchondral restoration. FsT1-w3DGE proved most appropriate identifying characteristic post-operative findings: the OATS group demonstrated bone marrow edema at the donor site and the graft/host interface showed significant enhancement in indirect MR-arthrography, indicating fibrocartilage. After crushed bone graft, we found an irregular structure and significant contrast uptake, consistent with remnants of bone grafts surrounded by inflammatory tissue. Conclusion: Indirect MR-arthrography is an accurate, non-invasive monitoring tool following OATS and crushed bone graft as the MRI scoring and grading system allows a reliable evaluation of normal and pathological osteochondral repair with a high histologic correlation.

  1. Shoulder, hip, and knee arthrography needle placement using fluoroscopic guidance: practice patterns of musculoskeletal radiologists in North America

    International Nuclear Information System (INIS)

    Shortt, Conor P.; Morrison, William B.; Deely, Diane M.; Gopez, Angela G.; Zoga, Adam C.; Roberts, Catherine C.

    2009-01-01

    The aim of this study was to evaluate the range of techniques used by radiologists performing shoulder, hip, and knee arthrography using fluoroscopic guidance. Questionnaires on shoulder, hip, and knee arthrography were distributed to radiologists at a national radiology meeting. We enquired regarding years of experience, preferred approaches, needle gauge, gadolinium dilution, and volume injected. For each approach, the radiologist was asked their starting and end needle position based on a numbered and lettered grid superimposed on a radiograph. Sixty-eight questionnaires were returned. Sixty-eight radiologists performed shoulder and hip arthrography, and 65 performed knee arthrograms. Mean experience was 13.5 and 12.8 years, respectively. For magnetic resonance arthrography, a gadolinium dilution of 1/200 was used by 69-71%. For shoulder arthrography, an anterior approach was preferred by 65/68 (96%). The most common site of needle end position, for anterior and posterior approaches, was immediately lateral to the humeral cortex. A 22-gauge needle was used by 46/66 (70%). Mean injected volume was 12.7 ml (5-30). For hip arthrography, an anterior approach was preferred by 51/68 (75%). The most common site of needle end position, for anterior and lateral approaches, was along the lateral femoral head/neck junction. A 22-gauge needle was used by 53/68 (78%). Mean injected volume was 11.5 ml (5-20). For knee arthrography, a lateral approach was preferred by 41/64 (64%). The most common site of needle end position, for lateral and medial approaches, was mid-patellofemoral joint level. A 22-gauge needle was used by 36/65 (56%). Mean injected volume was 28.2 ml (5-60). Arthrographic approaches for the shoulder, hip, and knee vary among radiologists over a wide range of experience levels. (orig.)

  2. Shoulder, hip, and knee arthrography needle placement using fluoroscopic guidance: practice patterns of musculoskeletal radiologists in North America

    Energy Technology Data Exchange (ETDEWEB)

    Shortt, Conor P. [Thomas Jefferson University Hospital, Department of Radiology, Philadelphia, PA (United States); Hospital of the University of Pennsylvania, Department of Radiology, Philadelphia, PA (United States); Morrison, William B.; Deely, Diane M.; Gopez, Angela G.; Zoga, Adam C. [Thomas Jefferson University Hospital, Department of Radiology, Philadelphia, PA (United States); Roberts, Catherine C. [Mayo Clinic College of Medicine, Department of Radiology, Phoenix, AZ (United States)

    2009-04-15

    The aim of this study was to evaluate the range of techniques used by radiologists performing shoulder, hip, and knee arthrography using fluoroscopic guidance. Questionnaires on shoulder, hip, and knee arthrography were distributed to radiologists at a national radiology meeting. We enquired regarding years of experience, preferred approaches, needle gauge, gadolinium dilution, and volume injected. For each approach, the radiologist was asked their starting and end needle position based on a numbered and lettered grid superimposed on a radiograph. Sixty-eight questionnaires were returned. Sixty-eight radiologists performed shoulder and hip arthrography, and 65 performed knee arthrograms. Mean experience was 13.5 and 12.8 years, respectively. For magnetic resonance arthrography, a gadolinium dilution of 1/200 was used by 69-71%. For shoulder arthrography, an anterior approach was preferred by 65/68 (96%). The most common site of needle end position, for anterior and posterior approaches, was immediately lateral to the humeral cortex. A 22-gauge needle was used by 46/66 (70%). Mean injected volume was 12.7 ml (5-30). For hip arthrography, an anterior approach was preferred by 51/68 (75%). The most common site of needle end position, for anterior and lateral approaches, was along the lateral femoral head/neck junction. A 22-gauge needle was used by 53/68 (78%). Mean injected volume was 11.5 ml (5-20). For knee arthrography, a lateral approach was preferred by 41/64 (64%). The most common site of needle end position, for lateral and medial approaches, was mid-patellofemoral joint level. A 22-gauge needle was used by 36/65 (56%). Mean injected volume was 28.2 ml (5-60). Arthrographic approaches for the shoulder, hip, and knee vary among radiologists over a wide range of experience levels. (orig.)

  3. Shoulder distention arthrography as a treatment modality

    International Nuclear Information System (INIS)

    Kang, Heung Sik; Park, Chan Sup; Kim, Jin Ho; Kim, Sang Bum

    1987-01-01

    18 patients with painful stiff shoulder joint were underwent shoulder distension arthrography as a treatment modality, followed by physical therapy. Range of motion of shoulder joint was evaluated at 1 week and 4 weeks after arthrography. The results were as follows; 1. Arthrographic findings were decreased volume of joint cavity, obliteration of axillary recess, small subscapularis bursa, serrated capsular margin and non-filling of biceps tendon sheath. In 3 cases, rotator cuff tear was found. 2. Range of motion of shoulder joint was improved after distension arthrography. 3. In 3 patients have rotator cuff tear, range of motion was not improved

  4. Combined nuclear and digital subtraction contrast arthrography in painful knee prosthesis

    International Nuclear Information System (INIS)

    Namasivayam, J.; Forrester, A.; Poon, F.W.; Cuthbert, G.F.; McKillop, J.H.; Bryan, A.S.

    1992-01-01

    The evaluation of a painful knee prosthesis remains a difficult problem for both orthopaedic surgeons and radiologists. We have compared digital subtraction arthrography with nuclear-arthrography in 7 patients with a painful knee prosthesis. Three patients showed a loose tibial component, demonstrated by both digital subtraction and nuclear arthrography. All 3 underwent revision of their prosthesis. One patient had an equivocal digital subtraction arthrogram and negative nuclear arthrogram, while both studies were negative in the 3 remaining patients. Nuclear arthrography is a simple procedure and can provide useful additional information when combined with digital subtraction arthrography. (orig.)

  5. Wrist ligament injuries: value of post-arthrography computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Theumann, N.; Schnyder, P.; Meuli, R. [Dept. of Diagnostic and Interventional Radiology, University Hospital, CHUV, Lausanne (Switzerland); Favarger, N. [Clinique Longeraie, Lausanne (Switzerland)

    2001-02-01

    Objective: To evaluate the use of post-arthrography high-resolution computed tomography in wrist ligament injuries.Design and patients: Thirty-six consecutive patients who had a history and clinical findings suggestive of ligamentous injuries of the wrist were prospectively studied. The findings of three-compartment arthrography and post-arthrography computed tomography (arthro-CT) were compared with those of arthroscopy. The evaluation concentrates on the detection and precise localization of ligament lesions in the triangular fibrocartilage (TFC), the scapholunate ligament (SLL) and the lunotriquetral ligament (LTL).Results: For TFC, SLL and LTL lesions, standard arthrography responded with a sensitivity and specificity of 85% and 100%, 85% and 100%, 80% and 100% respectively, while arthro-CT showed a sensitivity and specificity of 85% and 100%, 100% and 100%, 80% and 100% respectively. The precise localization of the lesions was possible only with arthro-CT.Conclusion: The sensitivity and specificity of standard arthrography and arthro-CT are similar, although the latter shows the site of tears or perforation with greater precision, while conventional arthrography demonstrates them indirectly. This precision is essential and may have clinical implications for the success of treatment procedures. (orig.)

  6. Optimization of the Contrast Mixture Ratio for Simultaneous Direct MR and CT Arthrography: an in Vitro Study

    International Nuclear Information System (INIS)

    Choi, Ja Young; Hong, Sung Hwan; Kim, Na Ra; Jun, Woo Sun; Moon, Sung Gyu; Kang, Heung Sik; Lee, Joon Woo; Choi, Jung Ah

    2008-01-01

    This study was designed to determine the optimal mixture ratio of gadolinium and iodinated contrast agent for simultaneous direct MR arthrography and CT arthrography. An in vitro study was performed utilizing mixtures of gadolinium at six different concentrations (0.625, 1.25, 2.5, 5.0, 10 and 20 mmol/L) and iodinated contrast agent at seven different concentrations (0, 12.5, 25, 37.5, 50, 75 and 92-99.9%). These mixtures were placed in tissue culture plates, and were then imaged with CT and MR (with T1-weighted sequences, proton-density sequences and T2-weighted sequences). CT numbers and signal intensities were measured. Pearson's correlation coefficients were used to assess the correlations between the gadolinium/iodinated contrast agent mixtures and the CT numbers/MR signal intensities. Scatter diagrams were plotted for all gadolinium/iodinated contrast agent combinations and two radiologists in consensus identified the mixtures that yielded the optimal CT numbers and MR signal intensities. The CT numbers showed significant correlation with iodinated contrast concentrations (r = 0.976, p < 0.001), whereas the signal intensities as measured on MR images showed a significant correlation with both gadolinium and iodinated contrast agent concentrations (r = -484 to -0.719, p < 0.001). A review of the CT and MR images, graphs, and scatter diagram of 42 combinations of the contrast agent showed that a concentration of 1.25 mmol/L gadolinium and 25% iodinated contrast agent was the best combination for simultaneous CT and MR imaging. A mixture of 1.25 mmol/L gadolinium and 25% iodinated contrast agent was found to be optimal for simultaneous direct MR arthrography and CT arthrography

  7. Accuracy of 3-Tesla MR and MR arthrography in diagnosis of meniscal retear in the post-operative knee

    Energy Technology Data Exchange (ETDEWEB)

    Magee, Thomas [NSI, Merritt Island, FL (United States); University of Central Florida School of Medicine, Orlando, FL (United States)

    2014-08-15

    This study assesses the accuracy of 3-Tesla (3-T) conventional MR imaging, 3-T MR arthrography, and the combined use of conventional MR and MR arthrography in the diagnosis of meniscal retears as compared with arthroscopy. The study also assess whether there are false-negative cases in which injected contrast does not extend into the meniscus despite a meniscal retear being seen on arthroscopy. One hundred consecutive knee MR arthrograms performed on patients with previous knee surgery were reviewed retrospectively. 3-T conventional MR imaging, 3-T MR arthrography, and the combined use of conventional MR and MR arthrography were assessed for meniscal retears as compared with arthroscopy. The criterion used to diagnose a meniscal retear on MR arthrogram was injected contrast tracking into the meniscus. All patients underwent second-look arthroscopy. Seventy-four patients had conventional MR findings consistent with a meniscal retear. In 83 of the 100 patients, intraarticular contrast helped in demonstrating a retear. In ten patients, there were MR findings consistent with a meniscal retear despite intra-articular contrast not tracking into the meniscus. Ninety-four of the 100 patients had meniscal retears on second-look arthroscopy. Three-Tesla conventional MR examination was 78 % sensitive and 75 % specific, MR arthrogram examination was 88 % sensitive and 100 % specific, and the combined use of MR and MR arthrogram imaging was 98 % sensitive and 75 % specific in the diagnosis of a meniscal retear. The combined use of 3-T MR and MR arthrography allows for high sensitivity and specificity in meniscal retear detection. In some patients, intraarticular contrast will not track into a meniscal retear. When MR findings are consistent with a meniscal retear but contrast does not extend into the meniscus, a meniscal retear is likely. (orig.)

  8. Arthrography of the ankle joint in chronic instability

    Energy Technology Data Exchange (ETDEWEB)

    Dory, M.A.

    1986-05-01

    Papers on arthrography of injuries of the lateral ligaments of the ankle relate mainly to recent distortion of the joint. Arthrography performed at a later stage after injury generally is considered useless. In fact, changes in chronic instability are observed; they are subtle and consist either of small recesses adjacent to the lateral malleolus or communication of the joint with the peroneal tendon sheaths. Arthrography was assessed in 61 cases of recurrent lateral sprains of the ankle more than 2 weeks after acute injury; 38 were considered as positive. Twenty-five patients had operative evaluation, with four false negative and one false positive results. Small recesses adjacent to the lateral malleolus or opacification of the peroneal tendon sheaths are sequelae of an acute sprain with tear of the anterior talofibular and/or the calcaneofibular ligaments. Although false negative results occur, arthrography is useful in the preoperative assessment of chronic ankle instability.

  9. Arthrography

    Medline Plus

    Full Text Available ... bear denotes child-specific content. Related Articles and Media Magnetic Resonance Imaging (MRI) - Musculoskeletal Radiation Dose in X-Ray and CT Exams Contrast Materials Magnetic Resonance Imaging (MRI) - Shoulder X-ray, ...

  10. Diagnosis of lesions of the acetabular labrum, of the labral-chondral transition zone, and of the cartilage in femoroacetabular impingement: Correlation between direct magnetic resonance arthrography and hip arthroscopy.

    Science.gov (United States)

    Crespo Rodríguez, A M; de Lucas Villarrubia, J C; Pastrana Ledesma, M A; Millán Santos, I; Padrón, M

    2015-01-01

    To determine the sensitivity and accuracy of direct MR arthrography in the diagnosis of intra-articular lesions associated with femoroacetabular impingement. We used direct MR arthrography to study 51 patients with femoroacetabular impingement who underwent arthroscopic hip surgery. Surgery demonstrated 37 labral tears, 44 lesions in the labral-chondral transitional zone, and 40 lesions of the articular cartilage. We correlated the findings at preoperative direct MR arthrography with those of hip arthroscopy and calculated the sensitivity, specificity, positive predictive value, negative predictive value, and validity index for direct MR arthrography. The sensitivity and specificity of MR arthrography were 94.5% and 100%, respectively, for diagnosing labral tears, 100% and 87.5%, respectively, for diagnosing lesions of the labral-chondral transition zone, and 92.5% and 54.5%, respectively, for diagnosing lesions of the articular cartilage. The negative predictive value of MR arthrography for lesions of the labral-chondral transitional zone was 100%. MR arthrography accurately defined extensive lesions of the cartilage and the secondary osseous changes (the main factor in poor prognosis), although its diagnostic performance was not so good in small chondral lesions. In patients with femoroacetabular impingement, direct MR arthrography can adequately detect and characterize lesions of the acetabular labrum and of the labral-chondral transitional zone as well as extensive lesions of the articular cartilage and secondary osseous changes. Copyright © 2013 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  11. Arthrography of the TMJ

    International Nuclear Information System (INIS)

    Jend, H.H.; Triebel, H.J.; Jend-Rossmann, I.; Hamburg Univ.

    1986-01-01

    Articular dysfunction of the TMJ with anterior displacement of the disc ('internal derangement') is an entity which has been separated from other types of the 'myofascial pain syndromes' and which can be treated conservatively or by surgery. Arthrography of the TMJ has contributed greatly to an understanding of normal and abnormal function and, in many cases, it can provide a diagnosis. On the basis of our experience with 80 investigations we discuss technical problems and the clinical indications. The indications for arthrography are in the pre-operative diagnosis, when clinical findings are uncertain, in order to demonstrate perforation, in order to confirm a suspected diagnosis and to assist in prosthetic treatment. (orig.) [de

  12. C1-2 arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Chevrot, A [Service de Radiologie B, Hopital Cochin, 75 - Paris (France); Cermakova, E [Service de Radiologie B, Hopital Cochin, 75 - Paris (France); Vallee, C [Service de Radiologie B, Hopital Cochin, 75 - Paris (France); Chancelier, M D [Service de Radiologie B, Hopital Cochin, 75 - Paris (France); Chemla, N [Service de Radiologie B, Hopital Cochin, 75 - Paris (France); Rousselin, B [Service de Radiologie B, Hopital Cochin, 75 - Paris (France); Langer-Cherbit, A [Service de Radiologie B, Hopital Cochin, 75 - Paris (France)

    1995-08-01

    One hundred patients with the following conditions were studied: cervical pain or neuralgia without radiographic changes, osteoarthritis, rheumatoid arthritis, ankylosing spondylarthritis and diverse conditions. The technique consists of lateral puncture of the posterior aspect of the C1-2 joint with a 20-gauge needle under fluoroscopic control, arthrography using 1 ml contrast medium, and a 1-ml long-acting steroid injection subsequently. The articular cavity has an anterior and a posterior recess. Sometimes the posterior recess is large. In 18% of cases the contralateral joint also opacifies. C1-2 arthrography appears to be an efficient and safe technique for the treatment of upper cervical pain due to C1-2 articular disorders. (orig.)

  13. C1-2 arthrography

    International Nuclear Information System (INIS)

    Chevrot, A.; Cermakova, E.; Vallee, C.; Chancelier, M.D.; Chemla, N.; Rousselin, B.; Langer-Cherbit, A.

    1995-01-01

    One hundred patients with the following conditions were studied: cervical pain or neuralgia without radiographic changes, osteoarthritis, rheumatoid arthritis, ankylosing spondylarthritis and diverse conditions. The technique consists of lateral puncture of the posterior aspect of the C1-2 joint with a 20-gauge needle under fluoroscopic control, arthrography using 1 ml contrast medium, and a 1-ml long-acting steroid injection subsequently. The articular cavity has an anterior and a posterior recess. Sometimes the posterior recess is large. In 18% of cases the contralateral joint also opacifies. C1-2 arthrography appears to be an efficient and safe technique for the treatment of upper cervical pain due to C1-2 articular disorders. (orig.)

  14. Arthrography of the ankle joint in chronic instability

    International Nuclear Information System (INIS)

    Dory, M.A.

    1986-01-01

    Papers on arthrography of injuries of the lateral ligaments of the ankle relate mainly to recent distortion of the joint. Arthrography performed at a later stage after injury generally is considered useless. In fact, changes in chronic instability are observed; they are subtle and consist either of small recesses adjacent to the lateral malleolus or communication of the joint with the peroneal tendon sheaths. Arthrography was assessed in 61 cases of recurrent lateral sprains of the ankle more than 2 weeks after acute injury; 38 were considered as positive. Twenty-five patients had operative evaluation, with four false negative and one false positive results. Small recesses adjacent to the lateral malleolus or opacification of the peroneal tendon sheaths are sequelae of an acute sprain with tear of the anterior talofibular and/or the calcaneofibular ligaments. Although false negative results occur, arthrography is useful in the preoperative assessment of chronic ankle instability. (orig.)

  15. The significance of preoperative shoulder arthrography in painful arc patients

    International Nuclear Information System (INIS)

    Myllylae, V.; Jalovaara, P.; Pyhtinen, J.; Oulu Univ.

    1984-01-01

    Preoperative shoulder arthrography was performed on 34 patients with painful arc syndromes. Rotator cuff rupture was diagnosed in 20 cases. Out of these the arthrography correctly showed rupture in 17 cases, while in one case rupture was not seen and two examinations were unsuccessful. Rotator cuff rupture was found in 14 cases at operation. Of these, arthrography had been negative in eight cases and in six cases the rupture had merely been suspected. Sensitivity of shoulder arthrography in showing rotator cuff rupture was thus 85%, specificity 57% and accuracy 74%. The biceps tendon was intact in all cases with rotator cuff rupture. S-called ''bicipital leakage'' was seen in four cases, but its significance remains unclear. (orig.) [de

  16. Arthrography in sport injuries of the knee joint

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, H

    1983-09-01

    The arthrography is one of the most important diagnostic methods of sport injuries of the knee joint. The examination must give an exact information to the surgeon; a good technique and standard X-rays are an absolute postulate. The submitted examinations are based on 6687 arthrographies during a period of 5 years. The arthrography should not be carried out before the acute symptomatology has ceased, usually after an interval of 2-3 weeks. Most frequent are the meniscus injuries by rotary traumas of the knee-joint. Football as the most popular sport is responsible for more than 50% of the injuries, followed by skiing, handball and jogging.

  17. Arthrography in sport injuries of the knee joint

    International Nuclear Information System (INIS)

    Schaefer, H.

    1983-01-01

    The arthrography is one of the most important diagnostic methods of sport injuries of the knee joint. The examination must give an exact information to the surgeon; a good technique and standard X-rays are an absolute postulate. The submitted examinations are based on 6687 arthrographies during a period of 5 years. The arthrography should not be carried out before the acute symptomatology has ceased, usually after an interval of 2-3 weeks. Most frequently are the meniscus injuries by rotary traumas of the knee-joint. Football as the most popular sport is responsible for more than 50% of the injuries, followed by skiing, handball and jogging. (orig.)

  18. Intrinsic carpal ligaments on MR and multidetector CT arthrography: comparison of axial and axial oblique planes

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ryan K.L.; Griffith, James F.; Ng, Alex W.H.; Law, Eric K.C. [The Chinese University of Hong Kong, Department of Imaging and Interventional Radiology, Prince Of Wales Hospital, Hong Kong (China); Tse, W.L.; Wong, Clara W.Y.; Ho, P.C. [The Chinese University of Hong Kong, Department of Orthopedics and Traumatology, Prince Of Wales Hospital, Hong Kong (China)

    2017-03-15

    To compare axial and oblique axial planes on MR arthrography (MRA) and multidetector CT arthrography (CTA) to evaluate dorsal and volar parts of scapholunate (SLIL) and lunotriquetral interosseous (LTIL) ligaments. Nine cadaveric wrists of five male subjects were studied. The visibility of dorsal and volar parts of the SLIL and LTIL was graded semi-quantitatively (good, intermediate, poor) on MRA and CTA. The presence of a ligament tear was determined on arthrosocopy and sensitivity, specificity and accuracy of tear detection were calculated. Oblique axial imaging was particularly useful for delineating dorsal and volar parts of the LTIL on MRA with overall 'good' visibility increased from 11 % to 78 %. The accuracy of MRA and CTA in revealing SLIL and LTIL tear was higher using the oblique axial plane. The overall accuracy for detecting SLIL tear on CTA improved from 94 % to 100 % and from 89 % to 94 % on MRA; the overall accuracy of detecting LTIL tear on CTA improved from 89 % to 100 % and from 72 % to 89 % on MRA Oblique axial imaging during CT and MR arthrography improves detection of tears in the dorsal and volar parts of both SLIL and LTIL. (orig.)

  19. Magnetic resonance tomography of the temporo-mandibular joints

    International Nuclear Information System (INIS)

    Katzberg, R.W.; Burgener, F.A.

    1986-01-01

    79 patients aged 6 to 66 years (9 men and 70 women) with abnormalities of the TMJs were examined by magnetic resonance tomography (132 joints) and the results were compared with CT (16 joints) and resonance tomography showed forward luxation of the meniscus in 82 joints (62%). In 34 joints (26%) the meniscus spontaneously resumed normal position when the mouth was open, but in 48 joints (36%) the displacement was permanent. The accuracy of resonance tomography was equal to that of arthrography and superior to CT. It was particularly suitable for follow-up examination after surgery (23 cases) when invasive arthrography would be contraindicated or difficult. Because of the high resolution of the soft tissue components in the TMJ, resonance tomography should be able to diagnose inflammatory and degenerative changes in the meniscus and ligaments. (orig.)

  20. Shoulder instability: the role of MR arthrography in diagnosing anteroinferior labroligamentous lesions our experience at king hussein medical center

    International Nuclear Information System (INIS)

    Hiari, A. A.

    2008-01-01

    To determine the reliability and accuracy of magnetic resonance arthrography of the shoulder for the diagnosis of anteroinferior labroligamentous lesions in patients with gleno-humeral joint instability. This retrospective study was performed at King Hussein Medical Center in Jordan. Twenty eight patients who underwent shoulder MR arthrogram and arthroscopy during a 22-month period were reviewed. All the twenty eight patients had history of previous shoulder dislocation and clinical suspicion of anteroinferior labroligamentous lesions and glenohumeral joint instability. The series included 24 males and 4 females. The mean average age of the patients was 29 years. All patients underwent shoulder MR arthrogram and the results of MR arthrogram were compared with the arthroscopic findings which were used as the reference standard. MR arthrograms were analyzed for the presence and type of labroligamentous injuries which include (Bankart, anterior labral periosteal sleeve avulsion (ALPSA), Perthes, glenolabral articular disruption (GLAD), or nonclassifiable lesion). Sensitivity, specificity and accuracy for the detection and classification of anteroinferior labroligamentous lesions with MR arthrography were calculated. At arthroscopy, 21 anteroinferior labroligamentous lesions were diagnosed, including 15 Bankart lesions, three ALPSA lesions, two Perthes lesions and one GLAD lesion. Seven labral lesions were nonclassifiable at arthroscopy, all of which occurred after a history of chronic instability. When compared with arthroscopic findings, Shoulder MR Arthrography had two false-negative results (sensitivity, 92.8%) and no false-positive results. The sensitivity of shoulder MR Arthrography in detecting anteroinferior labroligamentous lesions was 92.8% (26/28) and specificity was (100%). The overall accuracy of Shoulder MR Arthrography in detecting labroligamentous lesions in this study was 90.5% (19/21). MR arthrography of the shoulder is reliable and accurate in

  1. MRI (Magnetic Resonance Imaging)

    Science.gov (United States)

    ... Procedures Medical Imaging MRI (Magnetic Resonance Imaging) MRI (Magnetic Resonance Imaging) Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print Magnetic Resonance Imaging (MRI) is a medical imaging procedure for ...

  2. Double-compartment wrist arthrography

    International Nuclear Information System (INIS)

    Quinn, S.F.; Pittman, C.; Belsole, R.; Greene, T.L.; Rayhack, J.; Clark, R.A.; King, P.S.

    1987-01-01

    Seventy patients with clinical wrist problems were studied with double-compartment wrist arthrography. Midcarpal and radiocarpal compartment arthrograms were obtained in all patients. Digital subtraction technique was used to subtract out contrast from the first compartmental injection. Digital technique also allowed a dynamic record of each injection, which helped determine sites of intercompartmental communication. Postarthrography exercises recorded on videotape were performed after each injection. There were 34 normal studies. Abnormalities in the other 36 patients included: scapholunate communication (n = 9), lunatotriquetral communication (n = 6), communication with tendon sheaths (n = 4), communication with distal radioulnar compartment (n = 14), abnormal synovium process (n = 9), and communication through the radial or ulnar collateral ligament (n = 3). Double-compartment wrist arthrography may provide additional information for complex problems of the wrist

  3. Value of computed tomography arthrography with delayed acquisitions in the work-up of ganglion cysts of the tarsal tunnel: report of three cases

    International Nuclear Information System (INIS)

    Omoumi, Patrick; Gheldere, Antoine de; Leemrijse, Thibaut; Galant, Christine; Van den Bergh, Peter; Malghem, Jacques; Simoni, Paolo; Berg, Bruno C.V.; Lecouvet, Frederic E.

    2010-01-01

    Ganglion cysts are a common cause of tarsal tunnel syndrome. As in other locations, these cysts are believed to communicate with neighboring joints. The positive diagnosis and preoperative work-up of these cysts require identification and location of the cyst pedicles so that they may be excised and the risk of recurrence decreased. This can be challenging with ultrasonography and magnetic resonance (MR) imaging. We present three cases of symptomatic ganglion cysts of the tarsal tunnel, diagnosed by MR imaging, where computed tomography (CT) arthrography with delayed acquisitions helped to confirm the diagnosis and identify precisely the topography of the communication with the subtalar joint. These cases provide new evidence of the articular origin of ganglion cysts developing in the tarsal tunnel. (orig.)

  4. Multidetector Computed Tomography Arthrography of the Shoulder: Diagnostic Accuracy and Indications

    International Nuclear Information System (INIS)

    De Filippo, M.; Bertellini, A.; Sverzellati, N.; Pogliacomi, F.; Costantino, C.; Vitale, M.; Zappia, M.; Corradi, D.; Garlaschi, G.; Zompatori, M.

    2008-01-01

    Background: The presence of subcutaneous implants, such as permanent defibrillators, is an absolute contraindication to the use of magnetic resonance imaging (MRI). Moreover, MRI is unadvisable in subjects with metallic hardware near the area of study, as artifacts generated by such materials distort image quality. Purpose: To evaluate the diagnostic accuracy and indications of arthrography with multidetector computed tomography arthrography (arthro-MDCT) of the shoulder in patients with absolute or relative contraindications to MRI and in patients with periarticular metal implants using diagnostic arthroscopy as the gold standard. Material and Methods: After intraarticular injection of iodixanol and volumetric acquisition, 70 shoulders in 70 patients (30 females, 40 males, age range 32-60 years) were examined with a 16-detector-row CT scanner. The patients had arthralgia but no radiologically detected fractures. They could not be studied by MRI because of absolute contraindications (subcutaneous electronic implants), surgical metal implants, or claustrophobia. In 28 of the 70 patients who had had previous shoulder surgery, the arthro-CT examination was preceded by an MRI on the same day. All examinations were interpreted by two experienced musculoskeletal radiologists. The findings were compared with arthroscopic findings carried out within 28 days of the CT study. Results: In the 42 non-operated patients, the comparison between arthro-MDCT and arthroscopy showed sensitivity and specificity ranging between 87% and 100%. In the 28 operated shoulders, arthro-MDCT had an accuracy of 94% compared with 25% with MRI. Interobserver agreement was almost perfect (κ=0.95) in the evaluation of all types of lesions, both on MDCT and MRI. When arthro-MDCT was compared with MRI in the postoperative patients by a McNemar test, a significant difference (P<0.05) was found between these two techniques. Conclusion: Arthro-MDCT of the shoulder is a safe technique that provides

  5. Multidetector Computed Tomography Arthrography of the Shoulder: Diagnostic Accuracy and Indications

    Energy Technology Data Exchange (ETDEWEB)

    De Filippo, M.; Bertellini, A.; Sverzellati, N.; Pogliacomi, F.; Costantino, C.; Vitale, M.; Zappia, M.; Corradi, D.; Garlaschi, G.; Zompatori, M. (Dept. of Clinical Sciences, Section of Radiological Sciences, Univ. of Parma, Parma Hospital, Parma (Italy))

    2008-06-15

    Background: The presence of subcutaneous implants, such as permanent defibrillators, is an absolute contraindication to the use of magnetic resonance imaging (MRI). Moreover, MRI is unadvisable in subjects with metallic hardware near the area of study, as artifacts generated by such materials distort image quality. Purpose: To evaluate the diagnostic accuracy and indications of arthrography with multidetector computed tomography arthrography (arthro-MDCT) of the shoulder in patients with absolute or relative contraindications to MRI and in patients with periarticular metal implants using diagnostic arthroscopy as the gold standard. Material and Methods: After intraarticular injection of iodixanol and volumetric acquisition, 70 shoulders in 70 patients (30 females, 40 males, age range 32-60 years) were examined with a 16-detector-row CT scanner. The patients had arthralgia but no radiologically detected fractures. They could not be studied by MRI because of absolute contraindications (subcutaneous electronic implants), surgical metal implants, or claustrophobia. In 28 of the 70 patients who had had previous shoulder surgery, the arthro-CT examination was preceded by an MRI on the same day. All examinations were interpreted by two experienced musculoskeletal radiologists. The findings were compared with arthroscopic findings carried out within 28 days of the CT study. Results: In the 42 non-operated patients, the comparison between arthro-MDCT and arthroscopy showed sensitivity and specificity ranging between 87% and 100%. In the 28 operated shoulders, arthro-MDCT had an accuracy of 94% compared with 25% with MRI. Interobserver agreement was almost perfect (kappa=0.95) in the evaluation of all types of lesions, both on MDCT and MRI. When arthro-MDCT was compared with MRI in the postoperative patients by a McNemar test, a significant difference (P<0.05) was found between these two techniques. Conclusion: Arthro-MDCT of the shoulder is a safe technique that provides

  6. Usefulness of MR arthrography of the hip with leg traction in the evaluation of ligamentum teres injuries

    Energy Technology Data Exchange (ETDEWEB)

    Cerezal, Luis; Fernandez-Hernando, Moises [Department of Radiology, Diagnostico Medico Cantabria, Santander, Cantabria (Spain); Perez Carro, Luis [Learnig Trauma Med. Centro de Consultas Medicas CCM, Orthopedic Surgery department, Santander (Spain); Llorca, Javier [University of Cantabria - IDIVAL, Santander (Spain); CIBER Epidemiology and Public Health, Santander (Spain); Llopis, Eva [Alzira Hospital, Department of Radiology, Valencia (Spain); Montero, Juan Antonio [Cantabria University, Anatomy and Cell Biology, Santander (Spain); Canga, Ana [Cantabria University, Anatomy and Cell Biology, Santander (Spain); Department of Radiology Marques de Valdecilla University Hospital, Santander, Cantabria (Spain)

    2015-11-15

    To retrospectively evaluate the diagnostic accuracy of magnetic resonance (MR) arthrography of the hip with leg traction in the evaluation of ligamentum teres lesions and to evaluate whether there is increased articular distraction, possibly indicating secondary instability, in hips with ligamentum teres injuries. Institutional review board approval and informed consent were obtained for this retrospective study. MR arthrograms of the hip with leg traction of 184 consecutive patients, including 108 men (mean age, 32.6 years; range, 19-53 years) and 76 women (mean age, 38.5 years; range, 18-56 years), who underwent hip arthroscopy were assessed for the presence of ligamentum teres lesions. The MR arthrographic findings were independently assessed by two radiologists who were blinded to the arthroscopic results. The inclusion criteria stipulated no previous surgery, arthroscopy within 1 month after MR arthrography, and availability of a detailed surgical report with ligamentum teres findings. The arthroscopy findings served as the reference standard. Sensitivity, specificity, accuracy, and K statistics for interobserver and intraobserver agreement were calculated. At arthroscopy, 32 ligamentum teres injuries were found. The ligamentum teres was normal in 152 (82.6 %) patients and had suffered low-grade partial tears in 15 (8.1 %) patients, high-grade partial tears in 10 (5.4 %) patients, and complete ruptures in 7 (3.8 %) patients. MR arthrography with axial traction demonstrated moderate sensitivity and high specificity for both low-grade (62/93 %) and high-grade (66/96 %) partial tears. Grouping low- and high-grade partial tears increased the diagnostic performance of MR arthrography, yielding a sensitivity of 87 % and a specificity of 95 %. For complete ligamentum teres tears, MR arthrography with leg traction demonstrated high sensitivity (92 %) and specificity (98 %). Articular distraction was significantly increased in patients with complete ruptures of the

  7. Usefulness of MR arthrography of the hip with leg traction in the evaluation of ligamentum teres injuries

    International Nuclear Information System (INIS)

    Cerezal, Luis; Fernandez-Hernando, Moises; Perez Carro, Luis; Llorca, Javier; Llopis, Eva; Montero, Juan Antonio; Canga, Ana

    2015-01-01

    To retrospectively evaluate the diagnostic accuracy of magnetic resonance (MR) arthrography of the hip with leg traction in the evaluation of ligamentum teres lesions and to evaluate whether there is increased articular distraction, possibly indicating secondary instability, in hips with ligamentum teres injuries. Institutional review board approval and informed consent were obtained for this retrospective study. MR arthrograms of the hip with leg traction of 184 consecutive patients, including 108 men (mean age, 32.6 years; range, 19-53 years) and 76 women (mean age, 38.5 years; range, 18-56 years), who underwent hip arthroscopy were assessed for the presence of ligamentum teres lesions. The MR arthrographic findings were independently assessed by two radiologists who were blinded to the arthroscopic results. The inclusion criteria stipulated no previous surgery, arthroscopy within 1 month after MR arthrography, and availability of a detailed surgical report with ligamentum teres findings. The arthroscopy findings served as the reference standard. Sensitivity, specificity, accuracy, and K statistics for interobserver and intraobserver agreement were calculated. At arthroscopy, 32 ligamentum teres injuries were found. The ligamentum teres was normal in 152 (82.6 %) patients and had suffered low-grade partial tears in 15 (8.1 %) patients, high-grade partial tears in 10 (5.4 %) patients, and complete ruptures in 7 (3.8 %) patients. MR arthrography with axial traction demonstrated moderate sensitivity and high specificity for both low-grade (62/93 %) and high-grade (66/96 %) partial tears. Grouping low- and high-grade partial tears increased the diagnostic performance of MR arthrography, yielding a sensitivity of 87 % and a specificity of 95 %. For complete ligamentum teres tears, MR arthrography with leg traction demonstrated high sensitivity (92 %) and specificity (98 %). Articular distraction was significantly increased in patients with complete ruptures of the

  8. Indirect MR arthrography in the evaluation of tears of the glenoid labrum; Indirekte MR-Arthrographie in der Diagnostik von Laesionen des Labrum glenoidale

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, T.; Vahlensieck, M.; Lutterbey, G.; Pauleit, D.; Kreft, B.; Keller, E.; Schild, H. [Radiologische Universitaetsklinik Bonn (Germany); Wallny, T. [Orthopaedische Universitaetsklinik Bonn (Germany); Steuer, K.; Golombek, V. [Klinik fuer Unfallchirurgie, Univ. Bonn (Germany)

    1997-07-01

    Purpose: It has been shown that intravenous administration of contrast media produces an MR arthrographic effect without the need for intraarticular injection. This is the first study evaluating this new technique of indirect MR arthrography in the diagnosis of glenoid labrum tears. Methods: 28 patients with clinically suspected labral injuries were prospectively investigated (1.5 Tesla, flexible surface coil). A plain MR examination of the shoulder (transverse and oblique-coronal orientation, T{sub 1}-weighted spin- [T{sub E}/T{sub R} 15/675], proton density- and T{sub 2}*-weighted gradient echo [T{sub E}/T{sub R}/Flip 14,32/600/30 ] sequences) and indirect MR arthrography (transverse and oblique-coronal orientation, fat-suppressed T{sub 1}-weighted spin-echo sequences [T{sub E}/T{sub R} 15/675], intravenous injection of gadopentetate dimeglumine [0.1 mmol/kg], followed by 10-15 min of joint movement) were performed. Results were confirmed by arthroscopy and/or open surgery. Results: Indirect MR arthrography significantly improved delineation of the glenoid labrum and hyaline cartilage (p<0.05). Sensitivity and specificity of indirect MR arthrography in the diagnosis of labral injuries were 90% and 89%, compared to 79% and 67% of the native MR examination. Conclusion: Indirect MR arthrography is a promising non-invasive technique in the evaluation of the glenoid labrum. (orig.) [Deutsch] Ziel: In frueheren Studien wurde gezeigt, dass die intravenoese Injektion gadoliniumhaltiger Kontrastmittel zur Signalintensitaetssteigerung im Gelenkkavum fuehrt. In dieser Studie wurde erstmals diese Technik der indirekten MR-Arthrographie am Schultergelenk in der Diagnostik von Labrumlaesionen evaluiert. Methode: 28 Patienten mit klinischem Verdacht auf eine Verletzung des Labrum glenoidale und/oder der Rotatorenmanschette wurden prospektiv nach folgendem Protokoll an einem 1,5-Tesla-System mit einer Oberflaechen-Ringspule untersucht: 1. Native MR-Standard-Untersuchung mit

  9. Rotator cuff ruptures of the shoulder joint, sonography - arthrography

    International Nuclear Information System (INIS)

    Triebel, H.J.; Wening, V.; Witte, G.; Hamburg Univ.

    1986-01-01

    47 patients suspected of rutpure of the rotator cuff were sonographed and arthrographed. Rupture of the rotator cuff was diagnosed in 12 cases, both diagnostic methods yielding the same result. In 29 patients sonography and arthrography did not reveal any abnormal findings. Six ruptures evident in sonography were not confirmed by arthrography and were considered false positive. Direct pointers towards rupture of the cuff would be: echoless defects, cuff cannot be visualised fully or in part and irregularities of movement during dynamic examination. Echoless 'cystic' areas in the periarticular soft parts must be considered an indirect pointer. Echorich focal findings in the echopoor cuff represent a differential diagnostic problem and we cannot give a final assessment as yet. Shoulder sonography is justified as a screening method in suspicion of rotator cuff rupture before initiating arthrography. If sonography reveals no abnormal findings, shoulder arthrography need not be performed. (orig.) [de

  10. Current status of imaging of articular cartilage

    International Nuclear Information System (INIS)

    Hodler, J.; Resnick, D.

    1996-01-01

    Various imaging methods have been applied to assessment of articular cartilage. These include standard radiography, arthrography, CT, CT arthrography, ultrasonography, and MR imaging. Radiography remains the initial musculoskeletal imaging method. However, it is insensitive to early stages of cartilage abnormalities. MR imaging has great potential in the assessment of articular cartilage, although high-quality scans are required because imaging signs of cartilage abnormalities may be subtle. The potential and limitations of various sequences and techniques are discussed, including MR arthrography. The role of the other imaging methods in assessment of articular cartilage appears to be limited. (orig.). With 8 figs., 6 tabs

  11. Mediopatellar phase of the knee: Comparative evaluation by arthrography and arthroscopy

    International Nuclear Information System (INIS)

    Schouman-Claeys, E.; Dupont, J.Y.; Frija, G.

    1986-01-01

    One hundred consecutive knees were examined by arthrography and arthroscopy in a prospective study to determine the diagnostic value of arthrography in the detection and characterization of mediopatellar phase (nonpathalogic vs. pathologic). Statistical tests show that there are only two significant signs for the diagnosis of pathologic mediopatellar phase: length and thickness, No method is significantly superior for determining the pathologic character of the phase. This study demonstrated that compared to arthroscopy, arthrography has good sensitivity (86%) and excellent specificity (99%) for the detection of mediopatellar phase. The authors conclude that arthrography is as efficient as arthroscopy for the evaluation of the mediopatellar phase syndrome

  12. Radiologic evaluation of wrist arthrography

    International Nuclear Information System (INIS)

    Park, Yang Hee; Seong, Hyeun Lim; Yang, Jae Beom; Park, Chan Sup; Lee, Sang Seun

    1991-01-01

    Wrist arthrography allows direct visualization of the cartilage and synovial structure not seen in plain film. Arthrography of the wrist is valuable in evaluating patients with persistent wrist pain and limitation of motion after trauma. Wrist arthrography was performed in the evaluation of 30 patients with rheumatoid arthritis (2 cases), ganglions (12 cases), and wrist trauma (16 cases), and contrast media was injected in radiocarpal joint. The arthrographic findings were analyzed, and the results were as follows: In 16 patients with wrist trauma, 12 cases (75%) of compartment communication was seen including communication with distal radioulnar joint (44%), midcarpal joint (69%), and common carpometacarpal joint (63%). Of the total 30 patients, the pisiform-triquetral joint communicated with the radio carpal joint in 9 cases (30%). In 16 patients with trauma, the findings of post-traumatic arthritis included tendon communication (50%), irregular synovium (31%), and rupture of the joint capsule (25%). There was no lymphatic filling. Of 3 scaphoid fracture patients without bony callus formation, fibrous union was verified in one patient and nouncion in 2. O 12 patients with ganglion, communication between the ganglion and radiocarpal joint was seen in 2 cases and no communication in 10 cases

  13. Indirect MR-arthography in the fellow up of autologous osteochondral transplantation; Indirekte MR-Arthrographie zur Verlaufskontrolle nach autologer osteochondraler Transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Herber, S.; Pitton, M.B.; Kalden, P.; Thelen, M.; Kreitner, K.F. [Mainz Univ. (Germany). Klinik und Poliklinik fuer Radiologie; Runkel, M. [Mainz Univ. (Germany). Klinik und Poliklinik fuer Unfallchirurgie

    2003-02-01

    Purpose: To evaluate the spectrum of findings in indirect MR-arthrography following autologous osteochondral transplantation. Patients and Methods: 10 patients with autogenous osteochondral homografts underwent indirect MR-arthrography at three, 6 and 12 months postoperatively. The MR protocol at 1.5T comprised unenhanced imagings with PD- and T{sub 2}-weighted TSE-sequences with and without fat-suppression as well as T{sub 1}-weighted fat-suppressed SE-sequences before and after iv. contrast administration and after active joint exercise. Image analysis was done by two radiologists in conference and comprised the evaluation of signal intensity (SI) and integrity of the osseous plug and the cartilage surface, as well as the presence of joint effusion or bone marrow edema. Results: At three months, all cases demonstrated a significant bone marrow edema at the recipient and donor site that corresponded to a significant enhancement after iv. contrast administration. The interface between the transplant and the normal bone showed an increased SI at three and 6 months in T{sub 2}-weighted images as well as in indirect MR-arthrography. The marrow signal normalized in most cases after 6 to 12 months, indicating vitality and healing of the transplanted osteochondral graft. The SI of the interface decreased in the same period, demonstrating the stability of the homograft at the recipient site. The osteochondral plugs were well-seated in 9/10 cases. Indirect MR-arthrography was superior to unenhanced imaging in the assessment of the cartilage surface. Cartilage coverage was complete in every case. The transplanted hyaline cartilage as well as the original cartilage showed a significant increase of the SI in indirect MR-arthrography, that did not change in follow up studies. There were no pathological alterations of signal and thickness alterations of the transplanted cartilage in follow up investigations. Conclusion: Indirect MR-arthrography is a useful diagnostic tool

  14. Rotator cuff tears: assessment with MR arthrography in 275 patients with arthroscopic correlation

    International Nuclear Information System (INIS)

    Waldt, S.; Bruegel, M.; Mueller, D.; Holzapfel, K.; Rummeny, E.J.; Woertler, K.; Imhoff, A.B.

    2007-01-01

    We assessed the diagnostic performance of magnetic resonance (MR) arthrography in the diagnosis of articular-sided partial-thickness and full-thickness rotator cuff tears in a large symptomatic population. MR arthrograms obtained in 275 patients including a study group of 139 patients with rotator cuff tears proved by arthroscopy and a control group of 136 patients with arthroscopically intact rotator cuff tendons were reviewed in random order. MR imaging was performed on a 1.0 T system (Magnetom Expert, Siemens). MR arthrograms were analyzed by two radiologists in consensus for articular-sided partial-thickness and full-thickness tears of the supraspinatus, infraspinatus, and subscapularis tendons. At arthroscopy, 197 rotator cuff tears were diagnosed, including 105 partial-thickness (93 supraspinatus, nine infraspinatus, three subscapularis) and 92 full-thickness (43 supraspinatus, 20 infraspinatus, 29 subscapularis) tendon tears. For full-thickness tears, sensitivity, specificity, and accuracy were 96%, 99%, and 98%, respectively, and for partial tears 80%, 97%, and 95%, respectively. False negative and positive assessments in the diagnosis of articular-sided partial-thickness tears were predominantly [78% (35/45)] observed with small articular-sided (Ellman grade1) tendon tears. MR arthrography is highly accurate in the diagnosis of full-thickness rotator cuff tears and is accurate in the diagnosis of articular-sided partial-thickness tears. Limitations in the diagnosis of partial-thickness tears are mainly restricted to small articular-sided tears (Ellman grade 1) due to difficulties in differentiation between fiber tearing, tendinitis, synovitic changes, and superficial fraying at tendon margins. (orig.)

  15. Rotator cuff tears: assessment with MR arthrography in 275 patients with arthroscopic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Waldt, S.; Bruegel, M.; Mueller, D.; Holzapfel, K.; Rummeny, E.J.; Woertler, K. [Technische Universitaet Muenchen, Department of Radiology, Munich (Germany); Imhoff, A.B. [Technische Universitaet Muenchen, Department of Sports Orthopedics, Munich (Germany)

    2007-02-15

    We assessed the diagnostic performance of magnetic resonance (MR) arthrography in the diagnosis of articular-sided partial-thickness and full-thickness rotator cuff tears in a large symptomatic population. MR arthrograms obtained in 275 patients including a study group of 139 patients with rotator cuff tears proved by arthroscopy and a control group of 136 patients with arthroscopically intact rotator cuff tendons were reviewed in random order. MR imaging was performed on a 1.0 T system (Magnetom Expert, Siemens). MR arthrograms were analyzed by two radiologists in consensus for articular-sided partial-thickness and full-thickness tears of the supraspinatus, infraspinatus, and subscapularis tendons. At arthroscopy, 197 rotator cuff tears were diagnosed, including 105 partial-thickness (93 supraspinatus, nine infraspinatus, three subscapularis) and 92 full-thickness (43 supraspinatus, 20 infraspinatus, 29 subscapularis) tendon tears. For full-thickness tears, sensitivity, specificity, and accuracy were 96%, 99%, and 98%, respectively, and for partial tears 80%, 97%, and 95%, respectively. False negative and positive assessments in the diagnosis of articular-sided partial-thickness tears were predominantly [78% (35/45)] observed with small articular-sided (Ellman grade1) tendon tears. MR arthrography is highly accurate in the diagnosis of full-thickness rotator cuff tears and is accurate in the diagnosis of articular-sided partial-thickness tears. Limitations in the diagnosis of partial-thickness tears are mainly restricted to small articular-sided tears (Ellman grade 1) due to difficulties in differentiation between fiber tearing, tendinitis, synovitic changes, and superficial fraying at tendon margins. (orig.)

  16. Value of arthrography after supination trauma of the ankle

    Energy Technology Data Exchange (ETDEWEB)

    Dijk, C.N. van; Tol, J.L.; Marti, R.K. [Acad. Med. Centre, Amsterdam (Netherlands). Dept. of Orthopaedic Surg.; Molenaar, A.H.M. [Department of Radiology, Canisius Ziekenhuis, Weg door Jonkerbos 100, 6532 SZ Nijmegen (Netherlands); Cohen, R.H. [Department of Radiology, Stichting Ziekenhuis Amstelveen, Laan van de Helende Meesters 8, 1186 AM Amstelveen (Netherlands); Bossuyt, P.M.M. [Department of Epidemiology, Academic Medical Centre, P.O. Box 22700, 1100 DE Amsterdam (Netherlands)

    1998-05-01

    Objective. To investigate the merits of arthrography after supination trauma of the ankle. Design and patients. In a group of 160 consecutive patients operative exploration was performed in cases where arthrography and/or a delayed physical examination showed positive findings. In all patients arthrography was performed within 48 h after trauma. To determine interobserver agreement, all arthrograms were independently evaluated by two radiologists, both ignorant of the first assessment. Results. The prevalence of an ankle ligament lesion was found to be 76%. Of the 122 patients with a rupture of one or more ankle ligaments, 52% had an isolated anterior talofibular ligament lesion, 3% had an isolated calcaneofibular ligament lesion, and 45% had combined lesions. The site of the lesion was predominantly intraligamentous. In the determination of the presence or absence of an ankle ligament lesion, the specificity and sensitivity of the ankle arthrogram were 71% and 96% respectively. Interobserver agreement on the arthrogram was very good ({kappa} 0.9). In 1% of patients a clear diagnosis was not possible by means of arthrography. Conclusion. Arthrography provides information of high diagnostic quality with excellent interobserver agreement and therefore remains the gold standard for early diagnosis (within 48 h) of a lateral ankle ligament rupture. (orig.) With 4 figs., 5 tabs., 24 refs.

  17. Value of arthrography after supination trauma of the ankle

    International Nuclear Information System (INIS)

    Dijk, C.N. van; Tol, J.L.; Marti, R.K.; Cohen, R.H.; Bossuyt, P.M.M.

    1998-01-01

    Objective. To investigate the merits of arthrography after supination trauma of the ankle. Design and patients. In a group of 160 consecutive patients operative exploration was performed in cases where arthrography and/or a delayed physical examination showed positive findings. In all patients arthrography was performed within 48 h after trauma. To determine interobserver agreement, all arthrograms were independently evaluated by two radiologists, both ignorant of the first assessment. Results. The prevalence of an ankle ligament lesion was found to be 76%. Of the 122 patients with a rupture of one or more ankle ligaments, 52% had an isolated anterior talofibular ligament lesion, 3% had an isolated calcaneofibular ligament lesion, and 45% had combined lesions. The site of the lesion was predominantly intraligamentous. In the determination of the presence or absence of an ankle ligament lesion, the specificity and sensitivity of the ankle arthrogram were 71% and 96% respectively. Interobserver agreement on the arthrogram was very good (κ 0.9). In 1% of patients a clear diagnosis was not possible by means of arthrography. Conclusion. Arthrography provides information of high diagnostic quality with excellent interobserver agreement and therefore remains the gold standard for early diagnosis (within 48 h) of a lateral ankle ligament rupture. (orig.)

  18. MR Imaging of the Triangular Fibrocartilage Complex.

    Science.gov (United States)

    Cody, Michael E; Nakamura, David T; Small, Kirstin M; Yoshioka, Hiroshi

    2015-08-01

    MR imaging has emerged as the mainstay in imaging internal derangement of the soft tissues of the musculoskeletal system largely because of superior contrast resolution. The complex geometry and diminutive size of the triangular fibrocartilage complex (TFCC) and its constituent structures can make optimal imaging of the TFCC challenging; therefore, production of clinically useful images requires careful optimization of image acquisition parameters. This article provides a foundation for advanced TFCC imaging including factors to optimize magnetic resonance images, arthrography, detailed anatomy, and classification of injury. In addition, clinical presentations and treatments for TFCC injury are briefly considered. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Computed tomography arthrography using a radial plane view for the detection of triangular fibrocartilage complex foveal tears.

    Science.gov (United States)

    Moritomo, Hisao; Arimitsu, Sayuri; Kubo, Nobuyuki; Masatomi, Takashi; Yukioka, Masao

    2015-02-01

    To classify triangular fibrocartilage complex (TFCC) foveal lesions on the basis of computed tomography (CT) arthrography using a radial plane view and to correlate the CT arthrography results with surgical findings. We also tested the interobserver and intra-observer reliability of the radial plane view. A total of 33 patients with a suspected TFCC foveal tear who had undergone wrist CT arthrography and subsequent surgical exploration were enrolled. We classified the configurations of TFCC foveal lesions into 5 types on the basis of CT arthrography with the radial plane view in which the image slices rotate clockwise centered on the ulnar styloid process. Sensitivity, specificity, and positive predictive values were calculated for each type of foveal lesion in CT arthrography to detect foveal tears. We determined interobserver and intra-observer agreements using kappa statistics. We also compared accuracies with the radial plane views with those with the coronal plane views. Among the tear types on CT arthrography, type 3, a roundish defect at the fovea, and type 4, a large defect at the overall ulnar insertion, had high specificity and positive predictive value for the detection of foveal tears. Specificity and positive predictive values were 90% and 89% for type 3 and 100% and 100% for type 4, respectively, whereas sensitivity was 35% for type 3 and 22% for type 4. Interobserver and intra-observer agreement was substantial and almost perfect, respectively. The radial plane view identified foveal lesion of each palmar and dorsal radioulnar ligament separately, but accuracy results with the radial plane views were not statistically different from those with the coronal plane views. Computed tomography arthrography with a radial plane view exhibited enhanced specificity and positive predictive value when a type 3 or 4 lesion was identified in the detection of a TFCC foveal tear compared with historical controls. Diagnostic II. Copyright © 2015 American Society for

  20. Feasibility of ultrasonography and MR arthrography during evaluation of rotator cuff injury

    International Nuclear Information System (INIS)

    Hu, Jin Guang; Lee, Jong Min; Ryeom, Hun Kyu

    2005-01-01

    To evaluate the feasibility of MR arthrography and ultrasonography in evaluating shoulder pain. The subject group consisted of all patients who visited our institute complaining of shoulder pain or instability form June 2002 to December 2004. There were a total of 92 patients with an mean age of 48. On the basis of arthroscopic results, the sensitivity, specificity, and accuracy of ultrasonography and MR arthrography were evaluated by comparing them with each other. In the diagnosis of separateness tendon tears, ultrasonography had sensitivity and specificity of 100% and 64%, respectively, whereas MR arthrography had sensitivity and specificity of 80% and 94%, respectively. Ultrasonography also had high sensitivity and specificity in the diagnosis of subscapularis tendon tears (100% and 90%). MR arthrography was appropriate for identifying glenoid labral abnormalities (sensitivity, 95% and specificity, 61%). Similar results from ultrasonography and MR arthrography were obtained in the diagnosis of subscapular tendon tears or full-thickness tears of the rotator cuff tendons (kappa value, 0.644 and 0.911). While evaluating rotator cuff abnormalities, ultrasonography was appropriate for screening, whereas MR arthrography was useful to confirm the results of the ultrasonography

  1. Arthrography

    Medline Plus

    Full Text Available ... you! Do you have a personal story about radiology? Share your patient story here Images × Image Gallery ... Magnetic Resonance Imaging (MRI) - Shoulder X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to ...

  2. Pediatric magnetic resonance imaging

    International Nuclear Information System (INIS)

    Cohen, M.D.

    1986-01-01

    This book defines the current clinical potential of magnetic resonance imaging and focuses on direct clinical work with pediatric patients. A section dealing with the physics of magnetic resonance imaging provides an introduction to enable clinicians to utilize the machine and interpret the images. Magnetic resonance imaging is presented as an appropriate imaging modality for pediatric patients utilizing no radiation

  3. Ultrasonography and arthrography in rotator cuff lesions: algorithmic approach

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eui Jong; Ryu, Kyung Nam; Lee, Sun Wha; Lim, Jae Hoon; Rhee, Yong Girl [Kyung Hee University Hospital, Seoul (Korea, Republic of); Yu, Pil Mun [Dankuk University College of Medicine, Chenona (Korea, Republic of)

    1992-11-15

    Twenty-six patients with chief complaint of shoulder pain who underwent both ultrasonographic examination and arthrography of the shoulder were analyzed. Ten out of 12 cases with clinical impression of frozen shoulder, showed normal findings on the ultrasonographic examination of the shoulder. Among these ten cases, nine cases showed adhesive capsulitis and one case showed rotator cuff tear on arthrography. Among six cases with the clinical impression of rotator cuff tear, five cases showed rotator cuff tear and one case showed combined calcific tendinitis and adhesive capsulitis on ultrasonographic examination. In arthrography, four cases of rotator cuff tear, one case of calcific tendinitis and biceps tendinitis and one case of normal finding were diagnosed. For the remaining eight cases in the ultrasonographic examination, normal finding or biceps tendinitis were found and for the remaining of the cases in arthrography adhesive capsulitis were found. With the above results, we recommend that the shoulder ultrasonography as the first line diagnostic modality for a patient with chief complaint of shoulder pain.

  4. Ultrasonography and arthrography in rotator cuff lesions: algorithmic approach

    International Nuclear Information System (INIS)

    Kim, Eui Jong; Ryu, Kyung Nam; Lee, Sun Wha; Lim, Jae Hoon; Rhee, Yong Girl; Yu, Pil Mun

    1992-01-01

    Twenty-six patients with chief complaint of shoulder pain who underwent both ultrasonographic examination and arthrography of the shoulder were analyzed. Ten out of 12 cases with clinical impression of frozen shoulder, showed normal findings on the ultrasonographic examination of the shoulder. Among these ten cases, nine cases showed adhesive capsulitis and one case showed rotator cuff tear on arthrography. Among six cases with the clinical impression of rotator cuff tear, five cases showed rotator cuff tear and one case showed combined calcific tendinitis and adhesive capsulitis on ultrasonographic examination. In arthrography, four cases of rotator cuff tear, one case of calcific tendinitis and biceps tendinitis and one case of normal finding were diagnosed. For the remaining eight cases in the ultrasonographic examination, normal finding or biceps tendinitis were found and for the remaining of the cases in arthrography adhesive capsulitis were found. With the above results, we recommend that the shoulder ultrasonography as the first line diagnostic modality for a patient with chief complaint of shoulder pain

  5. Single and double contrast arthrography in lesions of the glenohumeral joint

    International Nuclear Information System (INIS)

    Ahovuo, J.

    1984-01-01

    One hundred and forty-five arthrograms from single and double contrast arthrography were compared with respect to their accuracy in revealing lesions of the glenohumeral joint. Total and partial rotator cuff tears were accurately delineated by both single and double contrast arthrography. The size of the tear did not correlate with surgical findings with either technique. The volume of the injected contrast medium was larger in full-thickness rotator cuff tears than in normal arthrograms (p 2 test). No difference in filling frequency of the sheath could be observed between single and double contrast arthrography. This study did not reveal any major advantages of double contrast arthrography over single contrast examinations in lesions of the rotator cuff and those of the tendon of the long head of the biceps brachii. (orig.)

  6. MR arthrography: Basics, technique, and first results

    International Nuclear Information System (INIS)

    Hajek, P.C.; Engel, A.; Kramer, J.; Imhof, H.

    1988-01-01

    Following evidence that intraarticular Gd-DTPA does not induce synovitis and is not stored in normal or chondropathic joint cartilage, the authors injected various concentrations of Gd-DTPA into 40 cadaveric and 40 in vivo knees. All in vivo knees underwent total prosthetic knee replacement, followed by a histologic workup. Results showed that MR arthrography greatly enhances the visibility of normal and pathologic structures and is a safe procedure. Moreover, MR arthrography seems to allow correct assessment and staging of various types of chondropathies

  7. SLAP tears: diagnosis using 3-T shoulder MR arthrography with the 3D isotropic turbo spin-echo space sequence versus conventional 2D sequences

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Joon-Yong; Jee, Won-Hee; Park, Michael Yong [The Catholic University of Korea, Department of Radiology, Seoul St. Mary' s Hospital, College of Medicine, Seoul (Korea, Republic of); Lee, So-Yeon [Sungkyunkwan University School of Medicine, Department of Radiology, Kangbuk Samsung Hospital, Seoul (Korea, Republic of); Kim, Yang-Soo [The Catholic University of Korea, Department of Orthopaedic Surgery, Seoul St. Mary' s Hospital, College of Medicine, Seoul (Korea, Republic of)

    2013-02-15

    The aim of this study was to determine the accuracy and reliability of shoulder magnetic resonance (MR) arthrography with three-dimensional (3D) isotropic intermediate-weighted turbo spin-echo (TSE) sampling perfection with application-optimised contrasts using different flip angle evolution (SPACE) in the diagnosis of superior labrum anterior-to-posterior (SLAP) lesions compared with two-dimensional (2D) TSE at 3.0 T. MR arthrograms, including 2D TSE and 3D TSE-SPACE, in 87 patients who underwent arthroscopy were retrospectively analysed by two reviewers for the presence and type of SLAP lesions. Sensitivity and specificity were compared using McNemar's test, and inter-observer agreement was calculated using Cohen's kappa. Receiver operating characteristic (ROC) curve analyses were performed. The mean sensitivity, specificity and accuracy were 90%, 85% and 86% for 2D TSE, and 81%, 86% and 85% for 3D TSE-SPACE respectively, with no statistically significant differences. Inter-observer agreements were substantial in 2D TSE ({kappa} = 0.76) and 3D TSE-SPACE ({kappa} = 0.68). The areas under the ROC curves were 0.92 for 2D TSE and 0.90 for 3D TSE-SPACE, which were not significantly different. MR arthrography with 3D TSE-SPACE showed comparable accuracy and substantial inter-observer agreement for the diagnosis of SLAP lesions circle MR arthrography is regarded as the definitive method of shoulder imaging circle Different MR sequences are evolving for SLAP lesions circle 3D TSE-SPACE demonstrated comparable overall accuracy to 2D TSE for SLAP lesions. (orig.)

  8. Efficacy of ultrasonography-guided shoulder MR arthrography using a posterior approach

    Energy Technology Data Exchange (ETDEWEB)

    Gokalp, Gokhan; Dusak, Abdurrahim; Yazici, Zeynep [Uludag University Medical Faculty, Goeruekle Kampusu, Department of Radiology, Bursa (Turkey)

    2010-06-15

    Shoulder MR arthrography has an important role in the assessment of rotator cuff lesions, labral tears, glenohumeral ligaments, rotator interval lesions, and postoperative shoulder status. Injection in direct MR arthrography can be performed with palpation, fluoroscopy, ultrasonography (US), or MRI. Recently, the posterior approach is the preferred method due to the presence of fewer stabilizers, absence of important articular structures and less extravasation, has been advocated. Our aim was to assess the efficacy of US-guided MR arthrography via a posterior approach on the glenohumeral joint. Thirty MR arthrographies were performed on 29 patients. Ultrasonography (Xario, Toshiba) examinations were conducted by a wide-band 5-12 Mhz linear array transducer set to muscle-skeleton. Diluted contrast medium (1 ml gadolinium chelate and 100 ml saline, approximately 15 ml) was delivered into the glenohumeral joint space from between the humeral head and posterior labrum with a 20-gauge spinal needle. MRI examination was conducted by a 1.5 T scanner. Fat-saturated T1-weighted spin echo was applied on coronal, axial, and sagittal planes within the first 30 min after contrast material injection. One (3.3%) arthrography was not successful due to technical reasons associated with obesity. Contrast extravasation around the infraspinatus and teres minoer muscles was depicted in twelve examinations. One (3.3%) patient developed vasovagal collapse. Ultrasonography-guided posterior approach is an easy, reliable, fast, and comfortable method in experienced hands. It may be an alternative for fluoroscopy-guided shoulder MR arthrography. (orig.)

  9. Efficacy of ultrasonography-guided shoulder MR arthrography using a posterior approach

    International Nuclear Information System (INIS)

    Gokalp, Gokhan; Dusak, Abdurrahim; Yazici, Zeynep

    2010-01-01

    Shoulder MR arthrography has an important role in the assessment of rotator cuff lesions, labral tears, glenohumeral ligaments, rotator interval lesions, and postoperative shoulder status. Injection in direct MR arthrography can be performed with palpation, fluoroscopy, ultrasonography (US), or MRI. Recently, the posterior approach is the preferred method due to the presence of fewer stabilizers, absence of important articular structures and less extravasation, has been advocated. Our aim was to assess the efficacy of US-guided MR arthrography via a posterior approach on the glenohumeral joint. Thirty MR arthrographies were performed on 29 patients. Ultrasonography (Xario, Toshiba) examinations were conducted by a wide-band 5-12 Mhz linear array transducer set to muscle-skeleton. Diluted contrast medium (1 ml gadolinium chelate and 100 ml saline, approximately 15 ml) was delivered into the glenohumeral joint space from between the humeral head and posterior labrum with a 20-gauge spinal needle. MRI examination was conducted by a 1.5 T scanner. Fat-saturated T1-weighted spin echo was applied on coronal, axial, and sagittal planes within the first 30 min after contrast material injection. One (3.3%) arthrography was not successful due to technical reasons associated with obesity. Contrast extravasation around the infraspinatus and teres minoer muscles was depicted in twelve examinations. One (3.3%) patient developed vasovagal collapse. Ultrasonography-guided posterior approach is an easy, reliable, fast, and comfortable method in experienced hands. It may be an alternative for fluoroscopy-guided shoulder MR arthrography. (orig.)

  10. Magnetic resonance imaging apparatus

    International Nuclear Information System (INIS)

    Ehnholm, G.J.

    1991-01-01

    This patent describes an electron spin resonance enhanced magnetic resonance (MR) imaging (ESREMRI) apparatus able to generate a primary magnetic field during periods of nuclear spin transition excitation and magnetic resonance signal detection. This allows the generation of ESREMRI images of a subject. A primary magnetic field of a second and higher value generated during periods of nuclear spin transition excitation and magnetic resonance signal detection can be used to generate conventional MR images of a subject. The ESREMRI and native MR images so generated may be combined, (or superimposed). (author)

  11. The detection of the capsular tear at the undersurface of the extensor carpi radialis brevis tendon in chronic tennis elbow: the value of magnetic resonance imaging and computed tomography arthrography.

    Science.gov (United States)

    Sasaki, Koichi; Tamakawa, Mitsuharu; Onda, Kazunori; Iba, Kosuke; Sonoda, Tomoko; Yamashita, Toshihiko; Wada, Takuro

    2011-04-01

    This study compared the diagnostic efficacy of magnetic resonance imaging (MRI) and computed tomography arthrography (CTA) in the assessment of capsular tears at the undersurface of the extensor carpi radials brevis tendon in chronic tennis elbow using arthroscopy as a gold standard. Because of the higher spatial resolution of CT, we hypothesized that CTA is superior to MRI for assessing capsular tears. We retrospectively reviewed 19 consecutive patients with chronic tennis elbow with preoperative MRI and CTA studies who underwent arthroscopic surgery. Three observers with different levels of training and experience (musculoskeletal radiologist, experienced elbow surgeon, and hand fellow) evaluated the capsular tear by MRI and CTA in a blinded manner. The results of the MRI and CTA were compared and the agreement among the 3 observers was determined using an intraclass correlation coefficient (ICC). Then, the results of the MRI and CTA examinations were compared with the intraoperative findings of the arthroscopic examination. The sensitivity, specificity, and κ value were calculated. The ICC of CTA (0.855) was superior to MRI (0.645). The sensitivity, specificity, and κ value of CTA were superior to those of MRI in each of the 3 observers. The κ value was 0.79, 0.89, and 0.79 for CTA, and 0.48, 0.48, and 0.27 for MRI for the radiologist, surgeon, and fellow, respectively. CTA was a reliable and accurate diagnostic modality compared with MRI to detect the capsular tear in patients with chronic tennis elbow. CTA was less influenced by the observer's experience. Copyright © 2011 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  12. Diagnosis of triangular fibrocartilage complex injury using arthrography and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Kiyonobu; Soejima, Osamu; Naito, Masatoshi [Fukuoka Univ. (Japan). School of Medicine

    2001-09-01

    Twenty patients (twenty-one wrists) with chronic ulnar wrist pain who had undergone radiocarpal arthrography and MRI before arthroscopic examination were evaluated to determine the usefulness of these preoperative diagnostic procedures (arthrogrphy and MRI) for the detection of triangular fibrocartilage complex (TFCC) injury. Based on the arthroscopic findings, the sensitivity and specificity of arthrography were 63% and 100% respectively for detecting TFCC lesions, while they were 68% and 50% respectively for MRI. Although no significant superiority was observed between arthrography and MRI in this study, further improrumchts in the preoperative diagnostic procedures are still needed in order to more accurately detect TFCC injuries. (author)

  13. Comparison between conventional MR arthrograhphy and abduction and external rotation MR arthrography in revealing tears of the antero-inferior glenoid labrum

    International Nuclear Information System (INIS)

    Choi, Jung Ah; Suh, Sang Il; Kim, Baek Hyun; Cha, Sang Hoon; Kim, Myung Gyu; Lee, Ki Yeol; Lee, Chang Hee

    2001-01-01

    To compare, in terms of their demonstration of tears of the anterior glenoid labrum, oblique axial MR arthrography obtained with the patient's shoulder in the abduction and external rotation (ABER) position, with conventional axial MR arthrography obtained with the patient's arm in the neutral position. MR arthrography of the shoulder, including additional oblique axial sequences with the patient in the ABER position, was performed in 30 patients with a clinical history of recurrent anterior shoulder dislocation. The degree of anterior glenoid labral tear or defect was evaluated in both the conventional axial and the ABER position by two radiologists. Decisions were reached by consensus, and a three-point scale was used: grade 1=normal; grade 2=probable tear, diagnosed when subtle increased signal intensity in the labrum was apparent; grade 3=definite tear/defect, when a contrast material-filled gap between the labrum and the glenoid rim or deficient labrum was present. The scores for each imaging sequence were averaged and to compare conventional axial and ABER position scans, Student's t test was performed. In 21 (70%) of 30 patients, the same degree of anterior instability was revealed by both imaging sequences. Eight (27%) had a lower grade in the axial position than in the ABER position, while one (3%) had a higher grade in the axial position. Three whose axial scan was grade 1 showed only equivocal evidence of tearing, but their ABER-position scan, in which a contrast material-filled gap between the labrum and the glenoid rim was present, was grade 3. The average grade was 2.5 (SD=0.73) for axial scans and 2.8 (SD=0.46) for the ABER position. The difference between axial and ABER-position scans was statistically significant (p<0.05). MR arthrography with the patient's shoulder in the ABER position is more efficient than conventional axial scanning in revealing the degree of tear or defect of the anterior glenoid labrum. When equivocal features are seen at

  14. MR-guided MR arthrography of the shoulder

    International Nuclear Information System (INIS)

    Tratting, S.; Breitenseher, M.; Pretterklieber, M.; Kontaxis, G.; Rand, T.; Imhof, H.

    1996-01-01

    Purpose: To develop an MR-guided technique for joint puncture in MR arthrography of the shoulder and to confirm the intracapsular position of the needle tip by visualization of the flow of contrast media into the joint. Materials and methods: Three unfixed human shoulder joint specimens were examined on a 1.0 T unit. The optimal point of entrance and depth for joint puncture were estimated by means of MR-compatible markers on the skin. Needle orientation and localization of the needle tip (MR-compatible 22-gauge needle) in the shoulder joint were monitored by rapid localizer gradient-echo sequences in two orthogonal planes. To confirm the intracapsular position of the needle tip, diluted gadolinium-DTPA was administered via a long connecting tube and the flow of contrast media into the joint was viewed directly on an LCD screen using real-time MR imaging (local look technique). Results: The MR-compatible markers on the skin allowed determination of the optimal point of entrance and estimation of the depth for joint puncture. Passive visualization of the MR-compatible needle due to spin dephasing and signal loss provided adequate localization of the intra-articular needle tip position in all specimens, although significant artefacts were present on rapid localizer gradient-echo sequences with an increase in width of the apparent needle shaft. Real-time MR imaging of the flow of contrast media was possible using the local look technique and the LCD screen of the MR unit and allowed confirmation of the intracapsular position. Conclusion: MR-guided joint puncture and real-time MR-assisted contrast media application results in improved MR arthrography and may replace conventional fluoroscopic guidance. (orig.) [de

  15. Comparison of shoulder positions at MR arthrography: change of labroligamentous complex shape and diagnosis of labral tears

    International Nuclear Information System (INIS)

    Kwak, Jin Young; Ha, Doo Hoe; Kim, Jeung Sook; Lee, Young Soo

    2001-01-01

    To compare the neutral, internal, and external rotation positions of the glenohumeral joint during magnetic resonance (MR) arthrography performed to assess changes in the shape of the labroligamentous complex (LLC) and in the labral tear. MR arthrography of the shoulder was retrospectively evaluated in 36 patients aged 14-66 (mean, 40) years. Fourteen cases were confirmed by arthroscopic surgery (7 SLAP lesions, 2 Bankart lesions, 1 both SLAP and Bankart lesions). Axial fat-suppressed T1-weighted spin-echo images were acquired with each shoulder in the neutral position, and with internal and external rotations. In each position, we measured the angle of rotation between the perpendicular line on the glenoid fossa and the long axis of the humeral head, analyzing the relationship between the rotational angle and changes in the shape of the LLC at each internal and external rotation, relative to the neutral position. In addition, labral tears in 14 arthroscopically confirmed joints were evaluated in each position. Mean angles of rotation relative to the neutral position were 44.1 and 45.3 degrees in internal and external rotation, respectively. Changes in the anterior LLC occurred in 25 and 24 cases of internal and external rotation, respectively. There was a significantly meaningful relationship between rotational angle and changes in the shape of the anterior LLC during external rotation, and when this changes was noticed, the rotational angle was wider (p<0.05). The posterior LLC changed in shape in 13 and 16 cases of internal and external rotation, respectively, but changes according to the angle of rotation were not statistically significant. In arthroscopically confirmed joints, diagnosis of the eight SLAP lesions at external rotation tended to become more accurate, but no statistically significant differences were noted (p=0.07). Two Bankart lesions were interpreted as a tear in all three positions, and one other such lesion was interpreted as a tear in the

  16. Gradient-recalled echo sequences in direct shoulder MR arthrography for evaluating the labrum

    International Nuclear Information System (INIS)

    Lee, Marc J.; Motamedi, Kambiz; Chow, Kira; Seeger, Leanne L.

    2008-01-01

    The purpose of this study was to determine the utility of fat-suppressed gradient-recalled echo (GRE) compared with conventional spin echo T1-weighted (T1W) sequences in direct shoulder MR arthrography for evaluating labral tears. Three musculoskeletal radiologists retrospectively reviewed MR arthrograms performed over a 12-month period for which surgical correlation was available. Of 180 serial arthrograms, 31 patients had surgery with a mean of 48 days following imaging. Paired coronal oblique and axial T1W or GRE sequences were analyzed by consensus for labral tear (coronal oblique two-dimensional multi-echo data image combination, 2D MEDIC; and axial three-dimensional double-echo steady-state, 3D DESS; Siemens MAGNETOM Sonata 1.5-T MR system). Interpretations were correlated with operative reports. Of 31 shoulders, 25 had labral tears at surgery. The GRE sequences depicted labral tears in 22, while T1W images depicted tears in 16 (sensitivity 88% versus 64%; p 0.7). Specificities were somewhat lower for GRE. Thin section GRE sequences are more sensitive than T1W for the detection of anterior and posterior labral tears. As the specificity of GRE was lower, it should be considered as an adjunctive imaging sequence that may improve depiction of labral tears, particularly smaller tears, in routine MR arthrography protocols. (orig.)

  17. Feasibility of ultrasound-guided intraarticular contrast injection for MR arthrography

    International Nuclear Information System (INIS)

    Baek, Soo Jin; Lee, Jong Min; Kang, Duck Sick

    2005-01-01

    To assess the feasibility of ultrasound-guided intraarticular contrast injection using the posterior approach for MR arthrography. Between June 2002 and October 2004, 132 patients (29 female, 103 male: mean age, 33.6 years) underwent ultrasound-guided intraarticular contrast media injection (40 ml saline + 10 ml 2% lidocaine + 0.2 ml gadopentetate dimeglumine + 0.4 ml epinephrine) for MR arthrography. The patients were classified into four groups, viz. the no leakage group, the minor leakage with successful intraarticular injection group, the major leakage with unsuccessful intraarticular injection group, and the injection failure group. The 'no leakage' and 'minor leakage' groups were considered to be technical successes, while the 'major leakage' and 'injection failure' groups were regarded as technical failures. The technical success rate of ultrasound-guided intraarticular contrast injection using the posterior approach for MR Arthrography was 99.2% (131/132 patients) and one patients 0.7% (1/132 patients) was included in the 'major leakage' group. Ultrasound-guided intraarticular contrast injection using the posterior approach for MR arthrography was feasible with a high success rate

  18. Comparative reliability and diagnostic performance of conventional 3T magnetic resonance imaging and 1.5T magnetic resonance arthrography for the evaluation of internal derangement of the hip

    Energy Technology Data Exchange (ETDEWEB)

    Chopra, A. [Chapel Allerton Hospital, Radiology Department, Leeds Teaching Hospitals, Leeds (United Kingdom); Grainger, A.J.; Robinson, Philip [Chapel Allerton Hospital, Radiology Department, Leeds Teaching Hospitals, Leeds (United Kingdom); Chapel Allerton Hospital, University of Leeds and NHIR Leeds Musculoskeletal Biomedical Research Centre, Leeds (United Kingdom); Dube, B.; Evans, R.; Hodgson, R. [Chapel Allerton Hospital, University of Leeds and NHIR Leeds Musculoskeletal Biomedical Research Centre, Leeds (United Kingdom); Conroy, J. [Harrogate and District NHS Trust, Trauma and Orthopaedics Department, Harrogate (United Kingdom); Macdonald, D. [Chapel Allerton Hospital, Trauma and Orthopaedics Department, Leeds Teaching Hospitals, Leeds (United Kingdom)

    2018-03-15

    To compare the diagnostic accuracy of conventional 3T MRI against 1.5T MR arthrography (MRA) in patients with clinical femoroacetabular impingement (FAI). Sixty-eight consecutive patients with clinical FAI underwent both 1.5T MRA and 3T MRI. Imaging was prospectively analysed by two musculoskeletal radiologists, blinded to patient outcomes and scored for internal derangement including labral and cartilage abnormality. Interobserver variation was assessed by kappa analysis. Thirty-nine patients subsequently underwent hip arthroscopy and surgical results and radiology findings were analysed. Both readers had higher sensitivities for detecting labral tears with 3T MRI compared to 1.5T MRA (not statistically significant p=0.07). For acetabular cartilage defect both readers had higher statistically significant sensitivities using 3T MRI compared to 1.5T MRA (p=0.02). Both readers had a slightly higher sensitivity for detecting delamination with 1.5T MRA compared to 3T MRI, but these differences were not statistically significant (p=0.66). Interobserver agreement was substantial to perfect agreement for all parameters except the identification of delamination (3T MRI showed moderate agreement and 1.5T MRA substantial agreement). Conventional 3T MRI may be at least equivalent to 1.5T MRA in detecting acetabular labrum and possibly superior to 1.5T MRA in detecting cartilage defects in patients with suspected FAI. circle Conventional 3T MRI is equivalent to 1.5T MRA for diagnosing labral tears. (orig.)

  19. A Simple Technique for Shoulder Arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Berna-Serna, J.D.; Redondo, M.V.; Martinez, F.; Reus, M.; Alonso, J.; Parrilla, A.; Campos, P.A. [Virgen de la Arrixaca Univ. Hospital, El Palmar, Murcia (Spain). Dept. of Radiology

    2006-09-15

    Purpose: To present a systematic approach to teaching a technique for arthrography of the shoulder. Using an adhesive marker-plate with radiopaque coordinates, precise sites for puncture can be identified and the need for fluoroscopic guidance obviated. Material and Methods: Forty-six glenohumeral arthrograms were performed in 45 patients; in 1 case involving examination of both shoulders. The stages of the technique are described in detail, as are the fundamental aspects of achieving an effective glenohumeral injection. Pain intensity was measured in all patients using a verbal description scale. Results: Shoulder arthrography was successful in all cases. Average time taken for the procedure was 7 min, with no difference in the respective times required by an experienced radiologist and a resident. The procedure was well tolerated by most patients, with slight discomfort being observed in a very few cases. Conclusion: The arthrographic technique used in this study is simple, safe, rapid, and reproducible, and has the advantage of precise localization of the site for puncture without need for fluoroscopic guidance. The procedure described in this study can be of help in teaching residents and can reduce the learning curve for radiologists with no experience in arthrographic methods. It also reduces the time of exposure to fluoroscopy Keywords: Arthrography, joint, shoulder.

  20. Freehand direct arthrography of the shoulder using near real-time guidance in an open 1.0-T MRI scanner

    Energy Technology Data Exchange (ETDEWEB)

    Wybranski, Christian [University Hospital of Cologne, Institute of Diagnostic and Interventional Radiology, Cologne (Germany); Adamchic, Ilya; Ricke, Jens; Fischbach, Frank; Fischbach, Katharina [Otto-von-Guericke University Medical School, Department of Radiology and Nuclear Medicine, Magdeburg (Germany); Roehl, Friedrich-Wilhelm [Otto-von-Guericke University Medical School, Institute of Biometry and Medical Informatics, Magdeburg (Germany)

    2017-01-15

    To assess the technical success and duration of magnetic resonance imaging (MRI)-guided freehand direct shoulder arthrography (FDSA) with near real-time imaging implemented in a routine shoulder MRI examination on an open 1.0-T MRI scanner, and to assess the learning curve of residents new to this technique. An experienced MRI interventionalist (the expert) performed 125 MRI-guided FDSA procedures, and 75 patients were treated by one of three residents without previous experience in MRI-guided FDSA. Technical success rate and duration of MRI-guided FDSA of the expert and the residents were compared. The residents' learning curves were assessed. The occurrence of extra-articular deposition and leakage of contrast media from the puncture site and the subsequent impairment of image interpretation were retrospectively analyzed. Overall technical success was 97.5 %. The expert needed overall fewer puncture needle readjustments and was faster at puncture needle positioning (p < 0.01). The learning curve of the residents, however, was steep. They leveled with the performance of the expert after ∼ 15 interventions. With a minimal amount of training all steps of MRI-guided FDSA can be performed in ≤10 min. Magnetic resonance-guided FDSA in an open 1.0-T MRI scanner can be performed with high technical success in a reasonably short amount of time. Only a short learning curve is necessary to achieve expert level. (orig.)

  1. Coxarthrosis - a radiological approach and guidelines

    International Nuclear Information System (INIS)

    Schueller, G.; Schueller-Weidekamm, C.

    2012-01-01

    Coxarthrosis is one of the most frequent indications in radiological practice with a prevalence as high as 8%. Radiography, sonography, computed tomography, magnetic resonance imaging. Magnetic resonance arthrography for detection of early stages of labral and chondral pathologies as well as detection of osteonecrosis at an early stage. Czerny C, Hofmann S, Neuhold A et al. (1996) Lesions of the acetabular labrum: accuracy of MR imaging and MR arthrography in detection and staging. Radiology 200(1):225-230. Czerny C, Oschatz E, Neuhold A et al. (2002) [MR arthrography of the hip joint]. Radiologe 42(6):451-456. Kramer J, Breitenseher M, Imhof H et al. (2000) [Diagnostic imaging in femur head necrosis]. Orthopade 29(5):380-388. Is already established in clinical practice. Each modality has relevant indications. (orig.) [de

  2. Arthrography

    Medline Plus

    Full Text Available ... ankle arthrogram. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Magnetic Resonance Imaging (MRI) - ...

  3. Children's (Pediatric) Magnetic Resonance Imaging

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging (MRI) ... limitations of Children’s (Pediatric) MRI? What is Children’s (Pediatric) MRI? Magnetic resonance imaging (MRI) is a noninvasive ...

  4. MR imaging appearance of discoid menisci of the knee

    International Nuclear Information System (INIS)

    Silverman, J.; Mink, J.H.; Deutsch, A.L.

    1988-01-01

    Although discoid menisci of the knee have been recognized with magnetic resonance (MR) imaging, there are no MR criteria for their diagnosis. In this paper the authors define a discord meniscus as three or more 5-mm-thick interleaved sagittal sections that demonstrate continuity of the meniscus between the anterior and posterior horns. High-resolution coronal images allow more graphic depiction of the abnormally wide meniscus. They present a total of 29 cases imaged with MR. In approximately one-third of their cases, the measurable height difference between the discoid meniscus and the adjacent meniscus was at least 2 mm. Surgical correlation revealed only two discrepancies between MR imaging and arthrography

  5. Magnetic Resonance Imaging (MRI) -- Head

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses a powerful ... the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that ...

  6. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging (MRI) ... limitations of Children’s (Pediatric) MRI? What is Children’s (Pediatric) MRI? Magnetic resonance imaging (MRI) is a noninvasive ...

  7. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging ( ... the limitations of Children’s (Pediatric) MRI? What is Children’s (Pediatric) MRI? Magnetic resonance imaging (MRI) is a ...

  8. The significance of arthrography and arthroscopy in the diagnosis of meniscus injury

    International Nuclear Information System (INIS)

    Eckel, H.; Linder, J.; Petzold, M.V.; Meyne, K.; Doerges, J.; Evangelisches Krankenhaus Goettingen

    1981-01-01

    The article reports on 364 double-contrast arthrographics and 185 arthroscopies.The results obtained in 126 patients in whom both arthrography and arthroscopy had been conducted, were compared. It became evident that arthrography is of high informative value in the diagnosis of lesions of the meniscus, so that preference may well be given to this method in non-specific knee-joint complaints where meniscopathy is suspected. Arthroscopies are indicated in cases of clinico-arthrographic coubt. Trial arthrotomy for clarifying doubtful meniscus lesions without previous exploitation of all arthrographic/arthroscopic possibilities is no longer justified and should be abandoned. Arthroscopy is definitely superior to arthrography in the diagnosis of, in particular, cartilage structures, of the synovia and of the retropatellar space. It is here where arthrography has its narrow limitations - now and in the future - for methodical reasons. (orig.) [de

  9. MR appearance of cartilage defects of the knee: preliminary results of a spiral CT arthrography-guided analysis

    International Nuclear Information System (INIS)

    Berg, B.C. vande; Lecouvet, F.E.; Maldague, B.; Malghem, J.

    2004-01-01

    The aim of this study was to determine signal intensity patterns of cartilage defects at MR imaging. The MR imaging (3-mm-thick fat-suppressed intermediate-weighted fast spin-echo images) was obtained in 31 knees (21 male and 10 female patients; mean age 45.5 years) blindly selected from a series of 252 consecutive knees investigated by dual-detector spiral CT arthrography. Two radiologists determined in consensus the MR signal intensity of the cartilage areas where cartilage defects had been demonstrated on the corresponding reformatted CT arthrographic images. There were 83 cartilage defects at spiral CT arthrography. In 52 (63%) lesion areas, the MR signal intensity was higher than that of adjacent normal cartilage with signal intensity equivalent to (n=31) or lower than (n=21) that of articular fluid. The MR signal intensity was equivalent to that of adjacent normal cartilage in 17 (20%) lesion areas and lower than that of adjacent cartilage in 8 (10%) lesion areas. In 6 (7%) lesion areas, mixed low and high signal intensity was observed. The MR signal intensity of cartilage defects demonstrated on spiral CT arthrographic images varies from low to high on fat-suppressed intermediate-weighted fast spin-echo MR images obtained with our equipment and MR parameters. (orig.)

  10. Cardiac magnetic resonance imaging

    African Journals Online (AJOL)

    2011-03-06

    Mar 6, 2011 ... Cardiac magnetic resonance imaging. Cardiovascular magnetic resonance imaging is becoming a routine diagnostic technique. BRUCE s sPOTTiswOOdE, PhD. MRC/UCT Medical Imaging Research Unit, University of Cape Town, and Division of Radiology, Stellenbosch University. Bruce Spottiswoode ...

  11. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses a powerful ... the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that ...

  12. Comparison study of indirect MR arthrography and direct MR arthrography of the shoulder

    International Nuclear Information System (INIS)

    Jung, Jee Young; Yoon, Young Cheol; Yi, Sang-Kyu; Yoo, Jaechul; Choe, Bong-Keun

    2009-01-01

    To compare the diagnostic value of indirect magnetic resonance arthrography (I-MRA) with that of direct MR arthrography (D-MRA) for labral tears, rotator cuff tears, and long head of biceps tendon (LHBT) tears using a 3-T MR unit. Institutional review board approval was given; written informed consent was obtained from all patients. From November 2005 to June 2006, 19 patients (eight men and 11 women; mean age, 51 years) who had undergone both I-MRA and D-MRA underwent arthroscopic surgery. Both methods were performed in fat-saturated axial, coronal oblique, and sagittal oblique T1-weighted sequences, as well as axial and coronal oblique T2-weighted sequences. Two radiologists independently and retrospectively evaluated two sets of MRA for the diagnosis of superior and anterior labral tears, subscapularis tendon (SSC), and supraspinatus-infraspinatus tendon (SSP-ISP) tears, and LHBT tears. With the arthroscopic finding as a gold standard, we analyzed statistical differences of sensitivities and specificities between two sets of MRA and inter-observer agreement was evaluated using the kappa value. The sensitivity and specificity of I-MRA and D-MRA for reader 1 were 79/80% and 71/80%, respectively, for superior labral tears; 100/100% and 100/100%, respectively, for anterior labral tears; 64/75% and 64/100%, respectively, for SSC tears; 100/86% and 100/100%, respectively, for SSP-ISP tears; and 67/100% and 78/100%, respectively, for LHBT tears. Those of I-MRA and D-MRA for reader 2 were 86/80% and 71/100%, respectively, for superior labral tears; 100/83% and 100/100%, respectively, for anterior labral tears; 64/88% and 82/100%, respectively, for SSC tears; 92/86% and 100/100%, respectively, for SSP-ISP tears; and 78/90% and 89/100%, respectively, for LHBT tears. No significant differences were found between the methods. Inter-observer agreements were higher than moderate (κ > 0.41) with both methods. Based on a relatively small number of patients, no significant

  13. Comparison study of indirect MR arthrography and direct MR arthrography of the shoulder

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Jee Young; Yoon, Young Cheol [Sungkyunkwan University, Department of Radiology, Samsung Medical Center, School of Medicine, Seoul (Korea); Yi, Sang-Kyu [Sungkyunkwan University, Department of Radiology, Samsung Medical Center, School of Medicine, Seoul (Korea); Sekye Radiologic Clinic, Daejeon (Korea); Yoo, Jaechul [Sungkyunkwan University, Department of Orthopedic Surgery, School of Medicine, Seoul (Korea); Choe, Bong-Keun [Kyung Hee University, Department of Preventive Medicine, School of Medicine, Seoul (Korea)

    2009-07-15

    To compare the diagnostic value of indirect magnetic resonance arthrography (I-MRA) with that of direct MR arthrography (D-MRA) for labral tears, rotator cuff tears, and long head of biceps tendon (LHBT) tears using a 3-T MR unit. Institutional review board approval was given; written informed consent was obtained from all patients. From November 2005 to June 2006, 19 patients (eight men and 11 women; mean age, 51 years) who had undergone both I-MRA and D-MRA underwent arthroscopic surgery. Both methods were performed in fat-saturated axial, coronal oblique, and sagittal oblique T1-weighted sequences, as well as axial and coronal oblique T2-weighted sequences. Two radiologists independently and retrospectively evaluated two sets of MRA for the diagnosis of superior and anterior labral tears, subscapularis tendon (SSC), and supraspinatus-infraspinatus tendon (SSP-ISP) tears, and LHBT tears. With the arthroscopic finding as a gold standard, we analyzed statistical differences of sensitivities and specificities between two sets of MRA and inter-observer agreement was evaluated using the kappa value. The sensitivity and specificity of I-MRA and D-MRA for reader 1 were 79/80% and 71/80%, respectively, for superior labral tears; 100/100% and 100/100%, respectively, for anterior labral tears; 64/75% and 64/100%, respectively, for SSC tears; 100/86% and 100/100%, respectively, for SSP-ISP tears; and 67/100% and 78/100%, respectively, for LHBT tears. Those of I-MRA and D-MRA for reader 2 were 86/80% and 71/100%, respectively, for superior labral tears; 100/83% and 100/100%, respectively, for anterior labral tears; 64/88% and 82/100%, respectively, for SSC tears; 92/86% and 100/100%, respectively, for SSP-ISP tears; and 78/90% and 89/100%, respectively, for LHBT tears. No significant differences were found between the methods. Inter-observer agreements were higher than moderate ({kappa} > 0.41) with both methods. Based on a relatively small number of patients, no significant

  14. Articular cartilage and labral lesions of the glenohumeral joint: diagnostic performance of 3D water-excitation true FISP MR arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Dietrich, Tobias Johannes [Orthopedic University Hospital Balgrist, Department of Radiology, Zurich (Switzerland); Kantonsspital Muensterlingen, Department of Radiology, PO Box 8596, Muensterlingen (Switzerland); Zanetti, Marco; Saupe, Nadja; Pfirrmann, Christian W.A.; Hodler, Juerg [Orthopedic University Hospital Balgrist, Department of Radiology, Zurich (Switzerland); Fucentese, Sandro F. [Hospital Balgrist, Department of Orthopedic Surgery, Orthopedic University, Zurich (Switzerland)

    2010-05-15

    To evaluate the diagnostic performance of MR arthrography in the detection of articular cartilage and labral lesions of the glenohumeral joint using a transverse 3D water-excitation true fast imaging with steady-state precession (FISP) sequence. Seventy-five shoulders were included retrospectively. Shoulder arthroscopy was performed within 6 months of MR arthrography. MR images were evaluated separately by two radiologists. They were blinded to clinical and arthroscopic information. Arthroscopy served as the reference standard. For the detection of humeral cartilage lesions, sensitivities and specificities were 86% (12/14)/89% (50/56) for observer 1 and 93%/86% for observer 2) for the transverse true FISP sequence and 64%/86% (50%/82% for observer 2) for the coronal intermediate-weighted spin-echo images. The corresponding values for the glenoidal cartilage were 60% (6/10)/88% (51/58) (80%/76% for observer 2) and 70%/86% (60%/74% for observer 2) respectively. For the detection of abnormalities of the anterior labrum (only assessed on true FISP images) the values were 94% (15/16)/84% (36/43) (88%/79% for observer 2). The corresponding values for the posterior labrum were 67% (8/12)/77% (36/47) (observer 2: 25%/74%). The kappa values for the grading of the humeral and glenoidal cartilage lesions were 0.81 and 0.55 for true FISP images compared with 0.49 and 0.43 for intermediate-weighted fast spin-echo images. Kappa values for true FISP evaluation of the anterior and posterior part of the labrum were 0.81 and 0.70. Transverse 3D true FISP MR arthrography images are useful for the difficult diagnosis of glenohumeral cartilage lesions and suitable for detecting labral abnormalities. (orig.)

  15. Magnetic resonance imaging

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    Magnetic resonance imaging (MRI) is a new and innovative technique that affords anatomic images in multiple planes and that may provide information about tissue characterization. The magnetic resonance images are obtained by placing the patient or the area of interest within a powerful, highly uniform, static magnetic field. Magnetized protons (hydrogen nuclei) within the patient align like small magnets in this field. Radiofrequency pulses are then used to create an oscillating magnetic field perpendicular to the main field. Magnetic resonance images differ from those produced by x-rays: the latter are associated with absorption of x-ray energy while magnetic resonance images are based on proton density and proton relaxation dynamics. Proton characteristics vary according to the tissue under examination and reflect its physical and chemical properties. To resolve issues regarding safety and efficacy, the Warren Grant Magnuson Clinical Center and the Office of Medical Applications of Research of the National Institutes of Health (NIH) convened a consensus conference about MRI Oct 26 through 28, 1987. At the NIH, the Consensus Development Conference brings together investigators in the biomedical sciences, clinical investigators, practicing physicians, and consumer and special interest groups to make a scientific assessment of technologies, including drugs, devices, and procedures, and to seek agreement on their safety and effectiveness

  16. Direct MR Arthrography of the wrist in comparison with Arthroscopy: A prospective study on 125 patients

    International Nuclear Information System (INIS)

    Schmitt, R.; Christopoulos, G.; Coblenz, G.; Froehner, S.; Meier, R.; Lanz, U.; Krimmer, H.

    2003-01-01

    Objective: In literature the diagnostic value of MRI for detecting lesions of the carpal ligaments and the TFCC is judged controversially. The aim of the following study is to determine the diagnostic accuracy of direct MR arthrography for depicting and staging of intraarticular lesions of the wrist. Material and methods: One day before undergoing arthroscopy, 125 patients suffering from wrist pain were examined with direct MR arthrography in a prospective and blinded study. A mixture of contrast medium (iodine-containing contrast medium and gadopentetate in relation 200:1) was injected into both radiocarpal and midcarpal joints. The following sequences were acquired on a 1.5T scanner: coronal T1-weighted SE, coronal fat-saturated T1-weighted SE, coronal T1-/T2*-DESS-3D, and sagittal T2*-weighted MEDIC. MRI results were compared with arthroscopic findings using statistical analysis (SEN=sensitivity, SPE=specificity, PPV=positive predictive value, NPV=negative predictive value, ACC=accuracy). Results: In comparison to arthroscopy as the accepted diagnostic gold standard, the following results were found for MR arthrography. Detection of TFCC lesions: SEN 97.1%, SPE 96.4%, PPV 97.1%, NPV 96.4%, ACC 96.8%. Detection of complete tears of the scapholunate ligament: SEN 91.7%, SPE 100%, PPV 100%, NPV 99.1%, ACC 99.2%. Detection of partial tears: SEN 62.5%, SPE 100%, PPV 100%, NPV 94.8%, ACC 95.2%. Detection of cartilage defects: SEN 84.2%, SPE 96.2%, PPV 80%, NPV 97.1%, ACC 94.4%. In total, only three lesions of the lunotriquetral ligament were present. Conclusion: Direct MR arthrographic imaging is well suited for detecting intraarticular lesions of the wrist. The presented diagnostic results of MR arthrography are superior to the results of unenhanced MRI reported in the literature. Direct MR arthrography as a reliable diagnostic tool is strongly recommended if lesions of the scapholunate ligament and the triangular fibrocartilage complex are suspected. In contrast, an

  17. Imaging of bursae around the shoulder joint

    International Nuclear Information System (INIS)

    Bureau, N.J.; Dussault, R.G.; Keats, T.E.

    1996-01-01

    The authors present a review of the anatomy of the major bursae around the shoulder joint and discuss the use of the different imaging modalities which demonstrate their radiologic features. The calcified subacromial-subdeltoid bursa has a characteristic appearance on plain radiographs. When inflamed it can be visualized by ultrasound and magnetic resonance imaging. Calcific bursitis may involve the subcoracoid bursa. This bursa may mimic adhesive capsulitis of the shoulder or complete rotator cuff tear when injected inadvertently during shoulder arthrography. Less well known are three coracoclavicular ligament bursae. These are also subject to calcific bursitis and have a typical radiologic appearance. (orig.). With 6 figs

  18. Imaging of bursae around the shoulder joint

    Energy Technology Data Exchange (ETDEWEB)

    Bureau, N.J. [Department of Radiology, Hotel-Dieu de Montreal Hospital, Montreal, Quebec (Canada); Dussault, R.G. [Department of Radiology, Health Sciences Center, University of Virginia, Charlottesville, Virginia (United States); Keats, T.E. [Department of Radiology, Health Sciences Center, University of Virginia, Charlottesville, Virginia (United States)

    1996-08-01

    The authors present a review of the anatomy of the major bursae around the shoulder joint and discuss the use of the different imaging modalities which demonstrate their radiologic features. The calcified subacromial-subdeltoid bursa has a characteristic appearance on plain radiographs. When inflamed it can be visualized by ultrasound and magnetic resonance imaging. Calcific bursitis may involve the subcoracoid bursa. This bursa may mimic adhesive capsulitis of the shoulder or complete rotator cuff tear when injected inadvertently during shoulder arthrography. Less well known are three coracoclavicular ligament bursae. These are also subject to calcific bursitis and have a typical radiologic appearance. (orig.). With 6 figs.

  19. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging (MRI) uses ... identify and accurately characterize diseases than other imaging methods. This detail makes MRI an invaluable tool in ...

  20. Magnetic resonance imaging

    International Nuclear Information System (INIS)

    Robertson, Angus

    1990-01-01

    An assessment is made of the clinical benefits of expensive diagnostic technology, such as the magnetic resonance imaging. It is concluded that to most radiologists, magnetic resonance imaging has a definite place in the diagnostic scenario, especially for demonstrating central nervous system lesions in multiple sclerosis. While it is recognized that medical and financial resources are limited, it is emphasised that the cost to society must be balanced against the patient benefit. 17 refs

  1. Arthrography of the hip in children

    International Nuclear Information System (INIS)

    Loennerholm, T.

    1980-01-01

    A method by which bilateral hip arthrography was performed under general anaesthesia in 130 infants and children 1 month to 7 years of age is described. Significant contractures of the adductor muscles had been corrected before the examination. Most of the children were girls with unilateral congenital idiopathic hip instability detected before the age of one year. From films exposed in standardized projections valuable information was obtained about the configuration of the joint cavity and the size and shape of the femoral head. Criteria for normal appearance in infants of ages 2 to 12 months are presented. More reliable details on the relation between the articular surfaces, the radiographic anatomy of the acetabulum and the distribution of the contrast medium were yielded by stereoradiography. Closed reduction was usually accomplished successfully during the arthrography, which made beginning of definitive treatment under the same anaesthesia possible. (Auth.)

  2. Conventional angiography in comparison with magnetic resonance tomography and arthroscopy for the diagnosis of knee joint lesion - specific indications?; Die konventionelle Arthrographie im Vergleich zu Magnetresonanztomographie und Arthroskopie bei Kniegelenkbinnenlaesionen: Verbleiben Indikationen?

    Energy Technology Data Exchange (ETDEWEB)

    Koenig, H. [Universitaetsklinikum Steglitz, Radiologische Klinik, Abt. fuer Roentgendiagnostik und Nuklearmedizin, FU Berlin (Germany); Andresen, R. [Universitaetsklinikum Steglitz, Radiologische Klinik, Abt. fuer Roentgendiagnostik und Nuklearmedizin, FU Berlin (Germany); Radmer, S. [Orthopaedisches Institut, Berlin (Germany); Schmidt, M. [Krankenhaus Moabit, Roentgenabteilung, Berlin (Germany); Wolf, K.J. [Universitaetsklinikum Steglitz, Radiologische Klinik, Abt. fuer Roentgendiagnostik und Nuklearmedizin, FU Berlin (Germany)

    1995-03-01

    Twenty-one patients with suspected internal knee joint lesions were examined prospectively. In all patients an MRI was carried out first and was followed within two weeks by an arthrography and an arthrocopy. Lesions of the menisci, cruciate ligaments, hyaline cartilage, and synovial tissues were evaluated. Arthroscopy findings were defined as the `gold standard`. MRI achieved an accuracy of 96.4%, a sensitivity of 93.6%, and a specifity of 92.5%, whereas arthrography achieved an accuracy of 67.8%, a sensitivity of 66.6%, and a specifity of 71.4%. These statistical data as well as the single findings revealed no special indications for arthrography in suspected knee joint lesions. (orig.) [Deutsch] In einer prospektiven Studie wurden insgesamt 21 Patienten mit suspekten Kniegelenksbinnenlaesionen untersucht. Bei allen Patienten erfolgte zunaechst eine Magnetresonanztomographie (MRT), anschliessend innerhalb von zwei Wochen eine Arthrographie und Arthroskopie des Kniegelenks. Beurteilt wurden Laesionen der Meniski, der Kreuzbaender, des hyalinen Gelenkknorpels und des Synovialgewebes. Bezogen auf den Arthroskopiebefund als `Gold-Standard` erreichte die MRT eine Treffsicherheit von 96,4%, eine Sensitivitaet von 93,6% und eine Spezifitaet von 92,5%; dagegen die Arthrographie eine Treffsicherheit von 67,8%, eine Sensitivitaet von 66,6% und eine Spezifitaet von 71,4%. Sowohl eine Uebersicht als auch die Auswertung der Einzelbefunde ergaben keine speziellen Indikationen zur Durchfuehrung einer Kniegelenksarthrographie bei suspekten Binnenlaesionen. (orig.)

  3. [Contribution of echogradient magnetic resonance imaging in the study of subacromial diseases. Surgical and arthrographic correlations].

    Science.gov (United States)

    Touzard, R C; Pigeau, I; Doursounian, L; Maigne, J Y; Vadrot, D

    1991-01-01

    Fifteen asymptomatic volunteers and 300 patients with suspected lesions of the rotator cuff were examined with T2*- and proton density-weighted gradient echo (T2*-Rho-GEI) MRI sequences (500-700 ms/30 ms/30 degrees) with a 0.5 T (GE-CGR) system and an adapted surface coil. For the patients, the findings were compared with those of arthrography in 130 cases and of surgery in 42 cases. For the operated patients, T2*-Rho-GEI and arthrography allowed correctly diagnosing 31 complete ruptures (CR). However, surgical exploration of the ruptures showed that T2*-Rho-GEI showed the actual extent of the rupture and the degree of tendon retraction better than arthrography. T2*-Rho-GEI also provides information about the thickness and trophicity of the remaining cuff and on local muscle trophicity. T2*-Rho-GEI allows directly evaluating the tendon of the long head of the biceps both in its extra-articular and its intra-articular parts. In 3 cases of complete cuff rupture, MRI allowed detecting 3 associated lesions of the anterior labrum, which had not been suspected on the clinical examination and had not been demonstrated by conventional arthrography. Lastly, out of 12 cases of deep incomplete rupture (n = 12) correctly diagnosed with MRI, 5 had been undetected on arthrography. Similarly, 8 cases of inflammatory alterations suspected with T2*-Rho-GEI and confirmed by surgery had not been recognized with arthrography. For the non-operated patients, T2*-Rho-GEI and arthrography had corresponding results for the diagnosis of CR (8 cases), of DIR (6 cases) and of intact cuff (6 cases).(ABSTRACT TRUNCATED AT 250 WORDS)

  4. Arthrography of the TMJ. Indications, technique and interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Jend, H.H.; Triebel, H.J.; Jend-Rossmann, I.

    1986-09-01

    Articular dysfunction of the TMJ with anterior displacement of the disc ('internal derangement') is an entity which has been separated from other types of the 'myofascial pain syndromes' and which can be treated conservatively or by surgery. Arthrography of the TMJ has contributed greatly to an understanding of normal and abnormal function and, in many cases, it can provide a diagnosis. On the basis of our experience with 80 investigations we discuss technical problems and the clinical indications. The indications for arthrography are in the pre-operative diagnosis, when clinical findings are uncertain, in order to demonstrate perforation, in order to confirm a suspected diagnosis and to assist in prosthetic treatment.

  5. Modern cartilage imaging of the ankle

    International Nuclear Information System (INIS)

    Weber, Marc-Andre; Wuennemann, Felix; Rehnitz, Christoph; Jungmann, Pia M.; Kuni, Benita

    2017-01-01

    Talar osteochondral lesions are an important risk factor for the development of talar osteoarthritis. Furthermore, osteochondral lesions might explain persistent ankle pain. Early diagnosis of accompanying chondral defects is important to establish the optimal therapy strategy and thereby delaying or preventing the onset of osteoarthritis. The purpose of this review is to explain modern cartilage imaging with emphasis of MR imaging as well as the discussion of more sophisticated imaging studies like CT-arthrography or functional MR imaging. Pubmed literature search concerning: osteochondral lesions, cartilage damage, ankle joint, talus, 2 D MR imaging, 3 D MR imaging, cartilage MR imaging, CT-arthrography, cartilage repair, microfracture, OATS, MACT. Dedicated MR imaging protocols to delineate talar cartilage and the appearance of acute and chronic osteochondral lesions were discussed. Recent developments of MR imaging, such as isotropic 3 D imaging that has a higher signal-to noise ratio when compared to 2 D imaging, and specialized imaging methods such as CT-arthrography as well as functional MR imaging were introduced. Several classifications schemes and imaging findings of osteochondral lesions that influence the conservative or surgical therapy strategy were discussed. MRI enables after surgery the non-invasive assessment of the repair tissue and the success of implantation. Key points: Modern MRI allows for highly resolved visualization of the articular cartilage of the ankle joint and of subchondral pathologies. Recent advances in MRI include 3 D isotropic ankle joint imaging, which deliver higher signal-to-noise ratios of the cartilage and less partial volume artifacts when compared with standard 2 D sequences. In case of osteochondral lesions MRI is beneficial for assessing the stability of the osteochondral fragment and for this discontinuity of the cartilage layer is an important factor. CT-arthrography can be used in case of contraindications of MRI and

  6. Resonance Energy Transfer Molecular Imaging Application in Biomedicine

    Directory of Open Access Journals (Sweden)

    NIE Da-hong1,2;TANG Gang-hua1,3

    2016-11-01

    Full Text Available Resonance energy transfer molecular imaging (RETI can markedly improve signal intensity and tissue penetrating capacity of optical imaging, and have huge potential application in the deep-tissue optical imaging in vivo. Resonance energy transfer (RET is an energy transition from the donor to an acceptor that is in close proximity, including non-radiative resonance energy transfer and radiative resonance energy transfer. RETI is an optical imaging technology that is based on RET. RETI mainly contains fluorescence resonance energy transfer imaging (FRETI, bioluminescence resonance energy transfer imaging (BRETI, chemiluminescence resonance energy transfer imaging (CRETI, and radiative resonance energy transfer imaging (RRETI. RETI is the hot field of molecular imaging research and has been widely used in the fields of biology and medicine. This review mainly focuses on RETI principle and application in biomedicine.

  7. Magnetic resonance imaging - first human images in Australia

    International Nuclear Information System (INIS)

    Baddeley, H.; Doddrell, D.M.; Brooks, W.M.; Field, J.; Irving, M.; Williams, J.E.

    1986-01-01

    The use of magnetic resonance imaging, in the demonstration of internal human anatomy and in the diagnosis of disease, has the major advantages that the technique is non-invasive, does not require the use of ionizing radiation and that it can demonstrate neurological and cardiovascular lesions that cannot be diagnosed easily by other imaging methods. The first magnetic resonance images of humans were obtained in Australia in October 1985 on the research instrument of the Queensland Medical Magnetic Resonance Research Centre, which is based at the Mater Hospital in Brisbane

  8. Magnetic Resonance Imaging (MRI) Safety

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) Safety What is MRI and how ... What is MRI and how does it work? Magnetic resonance imaging, or MRI, is a way of obtaining ...

  9. Direct MR-arthrography of the shoulder with maximum capsular distension for surgical planning

    International Nuclear Information System (INIS)

    Drescher, R.; Rothenburg, T. von; Koester, O.; Schmid, G.; Ludwig, J.

    2004-01-01

    Purpose: To evaluate the effectiveness of direct MR arthrography of the glenohumeral joint with maximum distension of the joint capsule in patients with glenohumeral instability for preoperative diagnosis and for determining the method of surgical intervention. Materials and Methods: MR arthrography of the shoulder joint was performed on a 1.5 T system in 38 patients. All patients suffered from anterior or bidirectional instability. Using a fluoroscopically guided posterior approach, a 1% dilution of dimeglumine gadopentetate (5 mmol Gd-DTPA/l) was injected until full capsular stretching was achieved. MR imaging protocol included fat-saturated transversal, oblique-coronal and oblique-sagittal T1-weighted spin-echo, T1-weighted 3-D and transversal T2-weighted Flash-2D. Results: MR imaging revealed significant capsule distention in 22 patients and ventral capsule defects in 9 patients. Labral lesions were depicted in 25 patients, bicipital tendon lesions in 4 patients and partial ruptures of the rotator cuff in 3 patients. 15 of the 38 patients underwent surgery. Areas of pathologic laxity of the glenohumeral capsule were correctly described in all cases. In 12 of 15 patients, the best method of intervention could be determined prospectively. In 3 of 15 patients, the necessary operation was overestimated. Regarding labral ruptures, MRI had a sensitivity of 88%, a specificity of 86%, and a diagnostic accuracy of 87%. (orig.)

  10. Direct MR Arthrography of the wrist in comparison with Arthroscopy: A prospective study on 125 patients; Direkte MR-Arthrographie des Handgelenks im Vergleich zur Arthroskopie: Eine prospektive Studie an 125 Patienten

    Energy Technology Data Exchange (ETDEWEB)

    Schmitt, R.; Christopoulos, G.; Coblenz, G.; Froehner, S. [Institut fuer Diagnostische und Interventionelle Radiologie der Herz- und Gefaessklinik GmbH, Bad Neustadt an der Saale (Germany); Meier, R.; Lanz, U.; Krimmer, H. [Klinik fuer Handchirurgie GmbH, Bad Neustadt an der Saale (Germany)

    2003-07-01

    Objective: In literature the diagnostic value of MRI for detecting lesions of the carpal ligaments and the TFCC is judged controversially. The aim of the following study is to determine the diagnostic accuracy of direct MR arthrography for depicting and staging of intraarticular lesions of the wrist. Material and methods: One day before undergoing arthroscopy, 125 patients suffering from wrist pain were examined with direct MR arthrography in a prospective and blinded study. A mixture of contrast medium (iodine-containing contrast medium and gadopentetate in relation 200:1) was injected into both radiocarpal and midcarpal joints. The following sequences were acquired on a 1.5T scanner: coronal T1-weighted SE, coronal fat-saturated T1-weighted SE, coronal T1-/T2*-DESS-3D, and sagittal T2*-weighted MEDIC. MRI results were compared with arthroscopic findings using statistical analysis (SEN=sensitivity, SPE=specificity, PPV=positive predictive value, NPV=negative predictive value, ACC=accuracy). Results: In comparison to arthroscopy as the accepted diagnostic gold standard, the following results were found for MR arthrography. Detection of TFCC lesions: SEN 97.1%, SPE 96.4%, PPV 97.1%, NPV 96.4%, ACC 96.8%. Detection of complete tears of the scapholunate ligament: SEN 91.7%, SPE 100%, PPV 100%, NPV 99.1%, ACC 99.2%. Detection of partial tears: SEN 62.5%, SPE 100%, PPV 100%, NPV 94.8%, ACC 95.2%. Detection of cartilage defects: SEN 84.2%, SPE 96.2%, PPV 80%, NPV 97.1%, ACC 94.4%. In total, only three lesions of the lunotriquetral ligament were present. Conclusion: Direct MR arthrographic imaging is well suited for detecting intraarticular lesions of the wrist. The presented diagnostic results of MR arthrography are superior to the results of unenhanced MRI reported in the literature. Direct MR arthrography as a reliable diagnostic tool is strongly recommended if lesions of the scapholunate ligament and the triangular fibrocartilage complex are suspected. In contrast, an

  11. Pseudotumoral ganglion cyst of a finger with unexpected remote origin: multimodality imaging

    International Nuclear Information System (INIS)

    Bouilleau, Loic; Malghem, Jacques; Omoumi, Patrick; Simoni, Paolo; Vande Berg, Bruno C.; Lecouvet, Frederic E.; Barbier, Olivier

    2010-01-01

    The case of a ganglion cyst in the pulp of a fifth finger in an elderly woman initially mimicking a soft tissue tumor is described. Most typical sites of ganglion cysts are well documented at the wrist and in the vicinity of inter-phalangeal and metacarpo-phalangeal joints. In this case, ultrasonography (US) and magnetic resonance imaging (MRI) demonstrated a cystic lesion within the pulp of the fifth finger and indicated carpal osteoarthritis as the distant - and unexpected - origin of the lesion. The suggested diagnosis of ganglion cyst was confirmed by computed tomography arthrography (CT arthrography) of the wrist, which showed opacification of the cyst on delayed acquisitions after intra-articular injection into the mid-carpal joint, through the fifth flexor digitorum tendon sheath. The communications between the degenerative carpal joint, the radio-ulnar bursa, the fifth flexor digitorum tendon sheath and the pedicle of the cyst were well demonstrated. (orig.)

  12. Gradient-recalled echo sequences in direct shoulder MR arthrography for evaluating the labrum

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Marc J.; Motamedi, Kambiz; Chow, Kira; Seeger, Leanne L. [David Geffen School of Medicine at UCLA, Department of Radiology, 200 UCLA Medical Plaza, Suite 165-59, Box 956952, Los Angeles, CA (United States)

    2008-01-15

    The purpose of this study was to determine the utility of fat-suppressed gradient-recalled echo (GRE) compared with conventional spin echo T1-weighted (T1W) sequences in direct shoulder MR arthrography for evaluating labral tears. Three musculoskeletal radiologists retrospectively reviewed MR arthrograms performed over a 12-month period for which surgical correlation was available. Of 180 serial arthrograms, 31 patients had surgery with a mean of 48 days following imaging. Paired coronal oblique and axial T1W or GRE sequences were analyzed by consensus for labral tear (coronal oblique two-dimensional multi-echo data image combination, 2D MEDIC; and axial three-dimensional double-echo steady-state, 3D DESS; Siemens MAGNETOM Sonata 1.5-T MR system). Interpretations were correlated with operative reports. Of 31 shoulders, 25 had labral tears at surgery. The GRE sequences depicted labral tears in 22, while T1W images depicted tears in 16 (sensitivity 88% versus 64%; p < 0.05). Subdividing the labrum, GRE was significantly more sensitive for the posterior labrum (75% versus 25%; p < 0.05) with a trend toward greater sensitivity at the anterior labrum (78% versus 56%; p = 0.157) but not significantly different for the superior labrum (50% versus 57%; p > 0.7). Specificities were somewhat lower for GRE. Thin section GRE sequences are more sensitive than T1W for the detection of anterior and posterior labral tears. As the specificity of GRE was lower, it should be considered as an adjunctive imaging sequence that may improve depiction of labral tears, particularly smaller tears, in routine MR arthrography protocols. (orig.)

  13. Magnetic Resonance Imaging of Stroke

    NARCIS (Netherlands)

    Bouts, Mark. J. R. J.; Wu, O.; Dijkhuizen, R. M.

    2017-01-01

    Magnetic resonance imaging (MRI) provides a powerful (neuro)imaging modality for the diagnosis and outcome prediction after (acute) stroke. Since MRI allows noninvasive, longitudinal, and three-dimensional assessment of vessel occlusion (with magnetic resonance angiography (MRA)), tissue injury

  14. Arthrography

    Medline Plus

    Full Text Available ... bear denotes child-specific content. Related Articles and Media Magnetic Resonance Imaging (MRI) - Musculoskeletal Radiation Dose in ... the web pages found at these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | ...

  15. Diagnosis of superior labral lesions: comparison of noncontrast MRI with indirect MR arthrography in unexercised shoulders

    International Nuclear Information System (INIS)

    Dinauer, Philip A.; Flemming, Donald J.; Murphy, Kevin P.; Doukas, William C.

    2007-01-01

    To prospectively compare the accuracy of noncontrast magnetic resonance imaging (MRI) with indirect MR arthrography (I-MRa) of unexercised shoulders for diagnosis of superior glenoid labral lesions. Institutional Review Board approval and patient informed consent were obtained for this prospective study. Superior labral findings on shoulder MRI and unexercised I-MRa studies of 104 patients were correlated with findings at arthroscopic shoulder surgery. Two musculoskeletal radiologists independently reviewed the two sets of MR images while blinded to arthroscopic results. For each radiologist, the McNemar test was used to detect statistically significant differences between techniques. The superior labrum was intact in 24 and abnormal in 80 subjects. For detection of superior labral lesions by each radiologist, I-MRa was more sensitive (84-91%) than MRI (66-85%), with statistically significant improvement in sensitivity for one reader (p = 0.003). However, I-MRa was less specific (58-71%) than MRI (75-83%). Overall, accuracy was slightly improved on I-MRa (78-86%) compared with MRI (70-83%), but this difference was not statistically significant for either reader. Compared with noncontrast MRI, I-MRa was more sensitive for diagnosis of superior glenoid labral lesions. However, the diagnostic value of I-MRa in shoulders remaining at rest is potentially limited by decreased specificity of the technique. (orig.)

  16. MDCT arthrography of the wrist: Diagnostic accuracy and indications

    International Nuclear Information System (INIS)

    De Filippo, Massimo; Pogliacomi, Francesco; Bertellini, Annalisa; Araoz, Philip A.; Averna, Raffaele; Sverzellati, Nicola; Ingegnoli, Anna; Corradi, Maurizio; Costantino, Cosimo; Zompatori, Maurizio

    2010-01-01

    Purpose: To evaluate the diagnostic accuracy and indications of arthrography with Multidetector Computed Tomography (arthro-MDCT) of the wrist in patients with absolute or relative contraindications to magnetic resonance imaging (MRI) studies and in patients with periarticular metal implants using diagnostic arthroscopy as the gold standard. Materials and methods: After intra-articular injection of iodixanol and volumetric acquisition, 43 wrists in patients of both genders (18 females, 25 males, age range 32-60 years) were examined with a 16-detector-row CT scanner. Fifteen patients had prior wrist surgery. The patients had arthralgia, degenerative and traumatic arthropathies as well as limited range of motion, but no radiologically detected fractures. All examinations were interpreted by two experienced musculoskeletal radiologists. The findings were compared with arthroscopic findings carried out within 28 days of the CT study. Results: In non-operated and operated wrists the comparison between arthro-MDCT and arthroscopy showed sensitivity, specificity and accuracy ranging between 92% and 94% for triangular fibrocartilage complex (TFCC), between 80% and 100% for intrinsic ligaments located within the proximal carpal compartment, and between 94% and 100% for articular cartilage. Inter-observer agreement between two radiologists, in the evaluation of all types of lesions, was almost perfect (k = 0.96) and statistically significant (p < 0.05). Conclusions: Arthro-MDCT of the wrist provides an accurate diagnosis to identify chondral, fibrocartilaginous and intra-articular ligament lesions in patients who cannot be evaluated by MRI, and in post-surgical patients.

  17. MDCT arthrography of the wrist: Diagnostic accuracy and indications

    Energy Technology Data Exchange (ETDEWEB)

    De Filippo, Massimo [Department of Clinical Sciences, Section of Radiological Sciences, University of Parma, Parma Hospital, Via Gramsci, 14, 43100 Parma (Italy)], E-mail: massimo.defilippo@unipr.it; Pogliacomi, Francesco [Orthopaedics, Traumatology and Functional Rehabilitation Unit, Department of Surgical Sciences, University of Parma, Parma Hospital, Via Gramsci 14, 43100 Parma (Italy); Bertellini, Annalisa [Department of Clinical Sciences, Section of Radiological Sciences, University of Parma, Parma Hospital, Via Gramsci, 14, 43100 Parma (Italy); Araoz, Philip A. [Department of Radiology, Division of Biostatistics, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (United States); Averna, Raffaele; Sverzellati, Nicola; Ingegnoli, Anna [Department of Clinical Sciences, Section of Radiological Sciences, University of Parma, Parma Hospital, Via Gramsci, 14, 43100 Parma (Italy); Corradi, Maurizio; Costantino, Cosimo [Orthopaedics, Traumatology and Functional Rehabilitation Unit, Department of Surgical Sciences, University of Parma, Parma Hospital, Via Gramsci 14, 43100 Parma (Italy); Zompatori, Maurizio [Department of Radiological and Histopathological Sciences, Policlinic S.Orsola-Malpighi, University of Bologna, Via Massarenti 9, 40138 Bologna (Italy)

    2010-04-15

    Purpose: To evaluate the diagnostic accuracy and indications of arthrography with Multidetector Computed Tomography (arthro-MDCT) of the wrist in patients with absolute or relative contraindications to magnetic resonance imaging (MRI) studies and in patients with periarticular metal implants using diagnostic arthroscopy as the gold standard. Materials and methods: After intra-articular injection of iodixanol and volumetric acquisition, 43 wrists in patients of both genders (18 females, 25 males, age range 32-60 years) were examined with a 16-detector-row CT scanner. Fifteen patients had prior wrist surgery. The patients had arthralgia, degenerative and traumatic arthropathies as well as limited range of motion, but no radiologically detected fractures. All examinations were interpreted by two experienced musculoskeletal radiologists. The findings were compared with arthroscopic findings carried out within 28 days of the CT study. Results: In non-operated and operated wrists the comparison between arthro-MDCT and arthroscopy showed sensitivity, specificity and accuracy ranging between 92% and 94% for triangular fibrocartilage complex (TFCC), between 80% and 100% for intrinsic ligaments located within the proximal carpal compartment, and between 94% and 100% for articular cartilage. Inter-observer agreement between two radiologists, in the evaluation of all types of lesions, was almost perfect (k = 0.96) and statistically significant (p < 0.05). Conclusions: Arthro-MDCT of the wrist provides an accurate diagnosis to identify chondral, fibrocartilaginous and intra-articular ligament lesions in patients who cannot be evaluated by MRI, and in post-surgical patients.

  18. Magnetic Resonance Imaging. Chapter 15

    Energy Technology Data Exchange (ETDEWEB)

    Leach, M. O. [The Institute of Cancer Research and The Royal Marsden Hospital, London (United Kingdom)

    2014-09-15

    In Chapter 14, the principles of nuclear magnetic resonance were presented, along with an introduction to image forming processes. In this chapter, magnetic resonance imaging (MRI) will be reviewed, beginning with the hardware needed and its impact on image quality. The acquisition processes and image reconstruction will be discussed, as well as the artefacts that are possible, with discussion of the important area of safety and bioeffects completing the chapter.

  19. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging (MRI) uses a powerful ... for an MRI exam contains a metal called gadolinium . Gadolinium can be used in patients with iodine ...

  20. [Arthrography of the temporomandibular joint. Indications, technic and interpretation].

    Science.gov (United States)

    Jend, H H; Triebel, H J; Jend-Rossmann, I

    1986-09-01

    Articular dysfunction of the TMJ with anterior displacement of the disc ("internal derangement") is an entity which has been separated from other types of the "myofascial pain syndromes" and which can be treated conservatively or by surgery. Arthrography of the TMJ has contributed greatly to an understanding of normal and abnormal function and, in many cases, it can provide a diagnosis. On the basis of our experience with 80 investigations we discuss technical problems and the clinical indications. The indications for arthrography are in the pre-operative diagnosis, when clinical findings are uncertain, in order to demonstrate perforation, in order to confirm a suspected diagnosis and to assist in prosthetic treatment.

  1. Arthrography

    Medline Plus

    Full Text Available ... resonance imaging (MRI) or fluoroscopy – a form of real-time x-ray. Your preparation may vary depending on ... to see bones, joints and internal organs in real time. When iodine contrast is injected into the joint, ...

  2. Evaluation of Labral Pathology and Hip Articular Cartilage in Patients with Femoroacetabular Impingement (FAI): Comparison of Multidetector CT Arthrography and MR Arthrography

    International Nuclear Information System (INIS)

    Sahin, Murat; Calisir, Cuneyt; Omeroglu, Hakan; Inan, Ulukan; Mutlu, Fezan; Kaya, Tamer

    2014-01-01

    To compare the multidetector computed tomography (MDCT) arthrography (CTa) and magnetic resonance (MR) arthrography (MRa) findings with surgical findings in patients with femoroacetabular impingement (FAI) and to evaluate the diagnostic performance of these methods. Labral pathology and articular cartilage were prospectively evaluated with MRa and CTa in 14 hips of 14 patients. The findings were evaluated by two musculoskeletal radiologists with 10 and 20 years of experience, respectively. Sensitivity, specificity, accuracy, and positive predictive value were determined using surgical findings as the standard of reference. While the disagreement between observers was recorded in two cases of labral tearing with MRa, there was a complete consensus with CTa. Disagreement between observers was found in four cases of femoral cartilage loss with both MRa and CTa. Disagreement was also recorded in only one case of acetabular cartilage loss with both methods. The percent sensitivity, specificity, and accuracy for correctly assessing the labral tearing were as follows for MRa/CTa, respectively: 100/100, 50/100, 86/100 (p<0.05). The same values for acetabular cartilage assessment were 89/56, 40/60, 71/71 (p>0.05) and for femoral cartilage assessment were 100/75, 90/70, 86/71 (p>0.05). Inter-observer reliability value showed excellent agreement for labral tearing with CTa (κ=1.0). Inter-observer agreement was substantial to excellent with regard to acetabular cartilage assessment with MRa and CTa (κ=0.76 for MRa and κ=0.86 for CTa) Inter-observer reliability with CTa is excellent for labral tearing assessment. CTa seems to have an equal sensitivity and a higher specificity than MRa for the detection of labral pathology. MRa is better, but not statistically significantly, in demonstrating acetabular and femoral cartilage pathology

  3. Advanced imaging of the scapholunate ligamentous complex

    Energy Technology Data Exchange (ETDEWEB)

    Shahabpour, Maryam; Maeseneer, Michel de; Boulet, Cedric; Mey, Johan de [Universitair Ziekenhuis Brussel (UZ Brussel), Department of Radiology, Brussels (Belgium); Staelens, Barbara; Scheerlinck, Thierry [Universitair Ziekenhuis Brussel (UZ Brussel), Department of Orthopaedics and Traumatology, Brussels (Belgium); Overstraeten, Luc van [Hand and Foot Surgery Unit (HFSU), Tournai (Belgium)

    2015-12-15

    The scapholunate joint is one of the most involved in wrist injuries. Its stability depends on primary and secondary stabilisers forming together the scapholunate complex. This ligamentous complex is often evaluated by wrist arthroscopy. To avoid surgery as diagnostic procedure, optimization of MR imaging parameters as use of three-dimensional (3D) sequences with very thin slices and high spatial resolution, is needed to detect lesions of the intrinsic and extrinsic ligaments of the scapholunate complex. The paper reviews the literature on imaging of radial-sided carpal ligaments with advanced computed tomographic arthrography (CTA) and magnetic resonance arthrography (MRA) to evaluate the scapholunate complex. Anatomy and pathology of the ligamentous complex are described and illustrated with CTA, MRA and corresponding arthroscopy. Sprains, mid-substance tears, avulsions and fibrous infiltrations of carpal ligaments could be identified on CTA and MRA images using 3D fat-saturated PD and 3D DESS (dual echo with steady-state precession) sequences with 0.5-mm-thick slices. Imaging signs of scapholunate complex pathology include: discontinuity, nonvisualization, changes in signal intensity, contrast extravasation (MRA), contour irregularity and waviness and periligamentous infiltration by edema, granulation tissue or fibrosis. Based on this preliminary experience, we believe that 3 T MRA using 3D sequences with 0.5-mm-thick slices and multiplanar reconstructions is capable to evaluate the scapholunate complex and could help to reduce the number of diagnostic arthroscopies. (orig.)

  4. Magnetic resonance imaging of the prostate

    DEFF Research Database (Denmark)

    Iversen, P; Kjaer, L; Thomsen, C

    1988-01-01

    Magnetic resonance imaging offers new possibilities in investigation of the prostate gland. Current results of imaging and tissue discrimination in the evaluation of prostatic disease are reviewed. Magnetic resonance imaging may be useful in the staging of carcinoma of the prostate....

  5. Diagnostic imaging of psoriatic arthritis. Part II: magnetic resonance imaging and ultrasonography

    Directory of Open Access Journals (Sweden)

    Iwona Sudoł-Szopińska

    2016-06-01

    Full Text Available Plain radiography reveals specific, yet late changes of advanced psoriatic arthritis. Early inflammatory changes are seen both on magnetic resonance imaging and ultrasound within peripheral joints (arthritis, synovitis, tendons sheaths (tenosynovitis, tendovaginitis and entheses (enthesitis, enthesopathy. In addition, magnetic resonance imaging enables the assessment of inflammatory features in the sacroiliac joints (sacroiliitis, and the spine (spondylitis. In this article, we review current opinions on the diagnostics of some selective, and distinctive features of psoriatic arthritis concerning magnetic resonance imaging and ultrasound and present some hypotheses on psoriatic arthritis etiopathogenesis, which have been studied with the use of magnetic resonance imaging. The following elements of the psoriatic arthritis are discussed: enthesitis, extracapsular inflammation, dactylitis, distal interphalangeal joint and nail disease, and the ability of magnetic resonance imaging to differentiate undifferentiated arthritis, the value of whole-body magnetic resonance imaging and dynamic contrast-enhanced magnetic resonance imaging.

  6. Magnetic resonance imaging the basics

    CERN Document Server

    Constantinides, Christakis

    2014-01-01

    Magnetic resonance imaging (MRI) is a rapidly developing field in basic applied science and clinical practice. Research efforts in this area have already been recognized with five Nobel prizes awarded to seven Nobel laureates in the past 70 years. Based on courses taught at The Johns Hopkins University, Magnetic Resonance Imaging: The Basics provides a solid introduction to this powerful technology. The book begins with a general description of the phenomenon of magnetic resonance and a brief summary of Fourier transformations in two dimensions. It examines the fundamental principles of physics for nuclear magnetic resonance (NMR) signal formation and image construction and provides a detailed explanation of the mathematical formulation of MRI. Numerous image quantitative indices are discussed, including (among others) signal, noise, signal-to-noise, contrast, and resolution. The second part of the book examines the hardware and electronics of an MRI scanner and the typical measurements and simulations of m...

  7. Magnetic resonance imaging of the prostate

    DEFF Research Database (Denmark)

    Iversen, P; Kjaer, L; Thomsen, C

    1987-01-01

    Magnetic resonance imaging offers new possibilities in the investigation of the prostate. The current results of imaging and tissue discrimination in the evaluation of prostatic disease are reviewed. Magnetic resonance imaging may be of value in the staging of carcinoma of the prostate....

  8. MR imaging in sports-related glenohumeral instability

    International Nuclear Information System (INIS)

    Woertler, Klaus; Waldt, Simone

    2006-01-01

    Sports-related shoulder pain and injuries represent a common problem. In this context, glenohumeral instability is currently believed to play a central role either as a recognized or as an unrecognized condition. Shoulder instabilities can roughly be divided into traumatic, atraumatic, and microtraumatic glenohumeral instabilities. In athletes, atraumatic and microtraumatic instabilities can lead to secondary impingement syndromes and chronic damage to intraarticular structures. Magnetic resonance (MR) arthrography is superior to conventional MR imaging in the diagnosis of labro-ligamentous injuries, intrinsic impingement, and SLAP (superior labral anteroposterior) lesions, and thus represents the most informative imaging modality in the overall assessment of glenohumeral instability. This article reviews the imaging criteria for the detection and classification of instability-related injuries in athletes with special emphasis on the influence of MR findings on therapeutic decisions. (orig.)

  9. Comparisons of the Various Partial-Thickness Rotator Cuff Tears on MR Arthrography and Arthroscopic Correlation

    Energy Technology Data Exchange (ETDEWEB)

    Chun, Kyung Ah; Kim, Min Sung; Kim, Young Joo [Catholic University of Korea Uijeongbu St.Mary' s Hospital, Uijeongbu (Korea, Republic of)

    2010-10-15

    To assess the diagnostic performance of MR arthrography in the diagnosis of the various types of partial-thickness rotator cuff tears by comparing the MR imaging findings with the arthroscopic findings. The series of MR arthrography studies included 202 patients consisting of 100 patients with partial-thickness rotator cuff tears proved by arthroscopy and a control group of 102 patients with arthroscopically intact rotator cuffs, which were reviewed in random order. At arthroscopy, 54 articularsided, 26 bursal-sided, 20 both articular- and bursal-sided partial-thickness tears were diagnosed. The MR arthrographies were analyzed by two radiologists for articular-sided tears, bursal-sided tears, and both articular- and bursal-sided tears of the rotator cuff. The sensitivity and specificity of each type of partial-thickness tears were determined. Kappa statistics was calculated to determine the interand intra-observer agreement of the diagnosis of partial-thickness rotator cuff tears. The sensitivity and specificity of the various types of rotator cuff tears were 85% and 90%, respectively for articular-sided tears, 62% and 95% for bursal- sided tears, as well as 45% and 99% for both articular- and bursal-sided tears. False-negative assessments were primarily observed in the diagnosis of bursal-sided tears. Conversely, both articular- and bursal-sided tears were overestimated as full-thickness tears. Inter-observer agreement was excellent for the diagnosis of articular-sided tears (k = 0.70), moderate (k = 0.59) for bursal-sided tears, and fair (k = 0.34) for both articular- and bursal-sided tears, respectively. Intra-observer agreement for the interpretation of articular- and bursal-sided tears was excellent and good, respectively, whereas intra-observer agreement for both articular- and bursal-sided tears was moderate. MR arthrography is a useful diagnostic tool for partial-thickness rotator cuff tears, but has limitations in that it has low sensitivity in bursal- and

  10. Comparisons of the Various Partial-Thickness Rotator Cuff Tears on MR Arthrography and Arthroscopic Correlation

    International Nuclear Information System (INIS)

    Chun, Kyung Ah; Kim, Min Sung; Kim, Young Joo

    2010-01-01

    To assess the diagnostic performance of MR arthrography in the diagnosis of the various types of partial-thickness rotator cuff tears by comparing the MR imaging findings with the arthroscopic findings. The series of MR arthrography studies included 202 patients consisting of 100 patients with partial-thickness rotator cuff tears proved by arthroscopy and a control group of 102 patients with arthroscopically intact rotator cuffs, which were reviewed in random order. At arthroscopy, 54 articularsided, 26 bursal-sided, 20 both articular- and bursal-sided partial-thickness tears were diagnosed. The MR arthrographies were analyzed by two radiologists for articular-sided tears, bursal-sided tears, and both articular- and bursal-sided tears of the rotator cuff. The sensitivity and specificity of each type of partial-thickness tears were determined. Kappa statistics was calculated to determine the interand intra-observer agreement of the diagnosis of partial-thickness rotator cuff tears. The sensitivity and specificity of the various types of rotator cuff tears were 85% and 90%, respectively for articular-sided tears, 62% and 95% for bursal- sided tears, as well as 45% and 99% for both articular- and bursal-sided tears. False-negative assessments were primarily observed in the diagnosis of bursal-sided tears. Conversely, both articular- and bursal-sided tears were overestimated as full-thickness tears. Inter-observer agreement was excellent for the diagnosis of articular-sided tears (k = 0.70), moderate (k = 0.59) for bursal-sided tears, and fair (k = 0.34) for both articular- and bursal-sided tears, respectively. Intra-observer agreement for the interpretation of articular- and bursal-sided tears was excellent and good, respectively, whereas intra-observer agreement for both articular- and bursal-sided tears was moderate. MR arthrography is a useful diagnostic tool for partial-thickness rotator cuff tears, but has limitations in that it has low sensitivity in bursal- and

  11. MR arthrography including abduction and external rotation images in the assessment of atraumatic multidirectional instability of the shoulder

    Energy Technology Data Exchange (ETDEWEB)

    Schaeffeler, Christoph [Technische Universitaet Muenchen, Department of Radiology, Munich (Germany); Kantonsspital Graubuenden, Musculoskeletal Imaging, Chur (Switzerland); Waldt, Simone; Bauer, Jan S.; Rummeny, Ernst J.; Woertler, Klaus [Technische Universitaet Muenchen, Department of Radiology, Munich (Germany); Kirchhoff, Chlodwig [Technische Universitaet Muenchen, Department of Traumatology, Munich (Germany); Haller, Bernhard [Technische Universitaet Muenchen, Institute for Medical Statistics and Epidemiology, Munich (Germany); Schroeder, Michael [Center for Sports Orthopedics and Medicine, Orthosportiv, Munich (Germany); Imhoff, Andreas B. [Technische Universitaet Muenchen, Department of Orthopedic Sports Medicine, Munich (Germany)

    2014-06-15

    To evaluate diagnostic signs and measurements in the assessment of capsular redundancy in atraumatic multidirectional instability (MDI) of the shoulder on MR arthrography (MR-A) including abduction/external rotation (ABER) images. Twenty-one MR-A including ABER position of 20 patients with clinically diagnosed MDI and 17 patients without instability were assessed by three radiologists. On ABER images, presence of a layer of contrast between the humeral head (HH) and the anteroinferior glenohumeral ligament (AIGHL) (crescent sign) and a triangular-shaped space between the HH, AIGHL and glenoid (triangle sign) were evaluated; centring of the HH was measured. Anterosuperior herniation of the rotator interval (RI) capsule and glenoid version were determined on standard imaging planes. The crescent sign had a sensitivity of 57 %/62 %/48 % (observers 1/2/3) and specificity of 100 %/100 %/94 % in the diagnosis of MDI. The triangle sign had a sensitivity of 48 %/57 %/48 % and specificity of 94 %/94 %/100 %. The combination of both signs had a sensitivity of 86 %/90 %/81 % and specificity of 94 %/94 %/94 %. A positive triangle sign was significantly associated with decentring of the HH. Measurements of RI herniation, RI width and glenoid were not significantly different between both groups. Combined assessment of redundancy signs on ABER position MR-A allows for accurate differentiation between patients with atraumatic MDI and patients with clinically stable shoulders; measurements on standard imaging planes appear inappropriate. (orig.)

  12. Spiral CT arthrography of the knee: technique and value in the assessment of internal derangement of the knee

    Energy Technology Data Exchange (ETDEWEB)

    Berg, Vande B.C.; Lecouvet, F.E.; Maldague, B.; Malghem, J. [Department of Radiology, Cliniques Universitaires St. Luc, Universite Catholique de Louvain, Brussels (Belgium); Poilvache, P. [Department of Orthopedic Surgery, Cliniques Universitaires St. Luc, Universite Catholique de Louvain, Brussels (Belgium)

    2002-07-01

    Computed tomography imaging has achieved excellent multiplanar capability and submillimeter spatial resolution due to the development of the spiral acquisition mode and multidetector row technology. Multidetector spiral CT arthrography (CTA) yields valuable information for the assessment of internal derangement of the joints. This article focuses on the value of spiral CTA of the knee in the assessment of the meniscus, anterior cruciate ligament, and hyaline cartilage lesions. Advantages and disadvantages of spiral CTA with respect to MR imaging are presented. (orig.)

  13. Diagnostic Value of CT Arthrography for Evaluation of Osteochondral Lesions at the Ankle

    Directory of Open Access Journals (Sweden)

    Jan S. Kirschke

    2016-01-01

    Full Text Available Background. To retrospectively determine the diagnostic value of computed tomography arthrography (CTA of the ankle in the evaluation of (osteochondral lesions in comparison to conventional magnetic resonance imaging (MRI and intraoperative findings. Methods. A total of N=79 patients had CTAs and MRI of the ankle; in 17/79 cases surgical reports with statements on cartilage integrity were available. Cartilage lesions and bony defects at talus and tibia were scored according to defect depth and size by two radiologists. Statistical analysis included sensitivity analyses and Cohen’s kappa calculations. Results. On CTA, 41/79 and 31/79 patients had full thickness cartilage defects at the talus and at the tibia, respectively. MRI was able to detect 54% of these defects. For the detection of full thickness cartilage lesions, interobserver agreement was substantial (0.72 ± 0.05 for CTA and moderate (0.55 ± 0.07 for MRI. In surgical reports, 88–92% and 46–62% of full thickness defects detected by CTA and MRI were described. CTA findings changed the further clinical management in 15.4% of cases. Conclusions. As compared to conventional MRI, CTA improves detection and visualization of cartilage defects at the ankle and is a relevant tool for treatment decisions in unclear cases.

  14. Imaging of the hip joint. Computed tomography versus magnetic resonance imaging

    Science.gov (United States)

    Lang, P.; Genant, H. K.; Jergesen, H. E.; Murray, W. R.

    1992-01-01

    The authors reviewed the applications and limitations of computed tomography (CT) and magnetic resonance (MR) imaging in the assessment of the most common hip disorders. Magnetic resonance imaging is the most sensitive technique in detecting osteonecrosis of the femoral head. Magnetic resonance reflects the histologic changes associated with osteonecrosis very well, which may ultimately help to improve staging. Computed tomography can more accurately identify subchondral fractures than MR imaging and thus remains important for staging. In congenital dysplasia of the hip, the position of the nonossified femoral head in children less than six months of age can only be inferred by indirect signs on CT. Magnetic resonance imaging demonstrates the cartilaginous femoral head directly without ionizing radiation. Computed tomography remains the imaging modality of choice for evaluating fractures of the hip joint. In some patients, MR imaging demonstrates the fracture even when it is not apparent on radiography. In neoplasm, CT provides better assessment of calcification, ossification, and periosteal reaction than MR imaging. Magnetic resonance imaging, however, represents the most accurate imaging modality for evaluating intramedullary and soft-tissue extent of the tumor and identifying involvement of neurovascular bundles. Magnetic resonance imaging can also be used to monitor response to chemotherapy. In osteoarthrosis and rheumatoid arthritis of the hip, both CT and MR provide more detailed assessment of the severity of disease than conventional radiography because of their tomographic nature. Magnetic resonance imaging is unique in evaluating cartilage degeneration and loss, and in demonstrating soft-tissue alterations such as inflammatory synovial proliferation.

  15. The clinical and radiological importance of extraarticular contrast material leakage into adjacent synovial compartments on ankle MR arthrography in patients with OCD and anterolateral impingement

    Energy Technology Data Exchange (ETDEWEB)

    Ogul, Hayri, E-mail: drhogul@gmail.com [Department of Radiology, Medical Faculty, Ataturk University, Erzurum (Turkey); Guzel, Yunus [Department of Orthopaedics and Traumatology, Medical Faculty, Ordu University, Ordu (Turkey); Pirimoglu, Berhan [Department of Radiology, Medical Faculty, Ataturk University, Erzurum (Turkey); Tuncer, Kutsi [Department of Orthopedic, Medical Faculty, Ataturk University, Erzurum (Turkey); Polat, Gokhan; Ergun, Fatih; Sade, Recep; Bayraktutan, Ummugulsum; Yuce, Ihsan; Kantarci, Mecit [Department of Radiology, Medical Faculty, Ataturk University, Erzurum (Turkey)

    2016-10-15

    Purpose: To evaluate the tibiotalar joint capacity and the localisation, frequency and amount of extravasation in patients with extraarticular contrast material leakage into adjacent synovial compartments on ankle magnetic resonance (MR) arthrography. Materials and methods: Sites of extravasation were determined in the ankle MR arthrograms of 69 patients. Thirty-four patients without extraarticular contrast material leakage into locations unrelated to the injection path were included as a control group. Volumetric measurements of extraarticular contrast material leakage and the tibiotalar joint capacity were performed on a three dimensional (3D) volume measurement workstation. Results: Extravasation of contrast material occurred through the anterior, posterior, and anterolateral recesses of the tibiotalar joint. The most common site of extravasation was along the flexor hallucis longus tendon synovium (24.6%). The amount of extravasation was significantly higher in patients with ankle osteochondritis dissecans (OCD) than in patients with a different diagnosis (p = 0.039). Loose bodies were detected in all OCD’s patients with insufficient tibiotalar joint distention. Conclusions: Connections between the ankle joint and neighboring synovial compartments can decrease the diagnostic value of ankle MR arthrography examinations due to inadequate joint distention. Large injection volumes should be used for ankle MR arthrography of patients with OCD (especially OCD’s patients with loose body) and impingement syndrome.

  16. The clinical and radiological importance of extraarticular contrast material leakage into adjacent synovial compartments on ankle MR arthrography in patients with OCD and anterolateral impingement

    International Nuclear Information System (INIS)

    Ogul, Hayri; Guzel, Yunus; Pirimoglu, Berhan; Tuncer, Kutsi; Polat, Gokhan; Ergun, Fatih; Sade, Recep; Bayraktutan, Ummugulsum; Yuce, Ihsan; Kantarci, Mecit

    2016-01-01

    Purpose: To evaluate the tibiotalar joint capacity and the localisation, frequency and amount of extravasation in patients with extraarticular contrast material leakage into adjacent synovial compartments on ankle magnetic resonance (MR) arthrography. Materials and methods: Sites of extravasation were determined in the ankle MR arthrograms of 69 patients. Thirty-four patients without extraarticular contrast material leakage into locations unrelated to the injection path were included as a control group. Volumetric measurements of extraarticular contrast material leakage and the tibiotalar joint capacity were performed on a three dimensional (3D) volume measurement workstation. Results: Extravasation of contrast material occurred through the anterior, posterior, and anterolateral recesses of the tibiotalar joint. The most common site of extravasation was along the flexor hallucis longus tendon synovium (24.6%). The amount of extravasation was significantly higher in patients with ankle osteochondritis dissecans (OCD) than in patients with a different diagnosis (p = 0.039). Loose bodies were detected in all OCD’s patients with insufficient tibiotalar joint distention. Conclusions: Connections between the ankle joint and neighboring synovial compartments can decrease the diagnostic value of ankle MR arthrography examinations due to inadequate joint distention. Large injection volumes should be used for ankle MR arthrography of patients with OCD (especially OCD’s patients with loose body) and impingement syndrome.

  17. Four years of experience with temporamandibular joint (TMJ) arthrography

    International Nuclear Information System (INIS)

    Duarte Filho, D.L.; Wagner, R.

    1990-01-01

    The imaging investigation of the internal derangements of temporomandibular joint (TMJ) has been recently enriched with state of the art tools, such as CT and MRI. However these equipments are not widely available in our country. In addition, some lesions such as perforation of the MJ meniscus, are not demonstrated by either one of these methods, been fairly easily showed by arthorography. The purpose of this paper is to show our experience with 386 arthrograms performed in 193 patients. Our results are compatible with those of the literature. In the last group of 176 patients, we have abandonned the local anesthesia procedure, with good advantages. Arthrography is a very usefull method in the evaluation of TMJ and should be more used in our country. (author)

  18. High-resolution 3T Magnetic Resonance Imaging of the Triangular Fibrocartilage Complex in Chinese Wrists: Correlation with Cross-sectional Anatomy.

    Science.gov (United States)

    Zhan, Hui-Li; Li, Wen-Ting; Bai, Rong-Jie; Wang, Nai-Li; Qian, Zhan-Hua; Ye, Wei; Yin, Yu-Ming

    2017-04-05

    The injury of the triangular fibrocartilage complex (TFCC) is a common cause of ulnar-sided wrist pain. The aim of this study was to investigate if the high-resolution 3T magnetic resonance imaging (MRI) could demonstrate the detailed complex anatomy of TFCC in Chinese. Fourteen Chinese cadaveric wrists (from four men and three women; age range at death from 30 to 60 years; mean age at 46 years) and forty healthy Chinese wrists (from 20 healthy volunteers, male/female: 10/10; age range from 21 to 53 years with a mean age of 32 years) in Beijing Jishuitan Hospital from March 2014 to March 2016 were included in this study. All cadavers and volunteers had magnetic resonance (MR) examination of the wrist with coronal T1-weighted and proton density-weighted imaging with fat suppression in three planes, respectively. MR arthrography (MRAr) was performed on one of the cadaveric wrists. Subsequently, all 14 cadaveric wrists were sliced into 2 mm thick slab with band saw (six in coronal plane, four in sagittal plane, and four in axial plane). The MRI features of normal TFCC were analyzed in these specimens and forty healthy wrists. Triangular fibrocartilage, the ulnar collateral ligament, and the meniscal homolog could be best observed on images in coronal plane. The palmar and dorsal radioulnar ligaments were best evaluated in transverse plane. The ulnotriquetral and ulnolunate ligaments were best visualized in sagittal plane. The latter two structures and the volar and dorsal capsules were better demonstrated on MRAr. High-resolution 3T MRI is capable to show the detailed complex anatomy of the TFCC and can provide valuable information for the clinical diagnosis in Chinese.

  19. Medulloblastoma: correlation among findings of conventional magnetic resonance imaging, diffusion-weighted imaging and proton magnetic resonance spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Fonte, Mariana Vieira de Melo da; Otaduy, Maria Concepcion Garcia; Lucato, Leandro Tavares; Reed, Umbertina Conti; Leite, Claudia da Costa [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Hospital das Clinicas. Inst. de Radiologia]. E-mail: mvmfonte@uol.com.br; Costa, Maria Olivia Rodrigues; Amaral, Raquel Portugal Guimaraes [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Faculdade de Medicina. Dept. de Radiologia; Reed, Umbertina Conti [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Faculdade de Medicina. Dept. de Neurologia; Rosemberg, Sergio [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Hospital das Clinicas. Dept. de Patologia

    2008-11-15

    To correlate imaging findings of medulloblastomas at conventional magnetic resonance imaging, diffusion-weighted imaging and proton magnetic resonance spectroscopy, comparing them with data in the literature. Preoperative magnetic resonance imaging studies of nine pediatric patients with histologically confirmed medulloblastomas (eight desmoplastic medulloblastoma, and one giant cell medulloblastoma) were retrospectively reviewed, considering demographics as well as tumors characteristics such as localization, morphology, signal intensity, contrast-enhancement, dissemination, and diffusion-weighted imaging and spectroscopy findings. In most of cases the tumors were centered in the cerebellar vermis (77.8%), predominantly solid (88.9%), hypointense on T 1-weighted images and intermediate/hyperintense on T 2-FLAIR-weighted images, with heterogeneous enhancement (100%), tumor dissemination/extension (77.8%) and limited water molecule mobility (100%). Proton spectroscopy acquired with STEAM technique (n = 6) demonstrated decreased Na a / Cr ratio (83.3%) and increased Co/Cr (100%) and ml/Cr (66.7%) ratios; and with PRESS technique (n = 7) demonstrated lactate peak (57.1%). Macroscopic magnetic resonance imaging findings in association with biochemical features of medulloblastomas have been useful in the differentiation among the most frequent posterior fossa tumors. (author)

  20. Medulloblastoma: correlation among findings of conventional magnetic resonance imaging, diffusion-weighted imaging and proton magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Fonte, Mariana Vieira de Melo da; Otaduy, Maria Concepcion Garcia; Lucato, Leandro Tavares; Reed, Umbertina Conti; Leite, Claudia da Costa; Costa, Maria Olivia Rodrigues; Amaral, Raquel Portugal Guimaraes; Reed, Umbertina Conti; Rosemberg, Sergio

    2008-01-01

    To correlate imaging findings of medulloblastomas at conventional magnetic resonance imaging, diffusion-weighted imaging and proton magnetic resonance spectroscopy, comparing them with data in the literature. Preoperative magnetic resonance imaging studies of nine pediatric patients with histologically confirmed medulloblastomas (eight desmoplastic medulloblastoma, and one giant cell medulloblastoma) were retrospectively reviewed, considering demographics as well as tumors characteristics such as localization, morphology, signal intensity, contrast-enhancement, dissemination, and diffusion-weighted imaging and spectroscopy findings. In most of cases the tumors were centered in the cerebellar vermis (77.8%), predominantly solid (88.9%), hypointense on T 1-weighted images and intermediate/hyperintense on T 2-FLAIR-weighted images, with heterogeneous enhancement (100%), tumor dissemination/extension (77.8%) and limited water molecule mobility (100%). Proton spectroscopy acquired with STEAM technique (n = 6) demonstrated decreased Na a / Cr ratio (83.3%) and increased Co/Cr (100%) and ml/Cr (66.7%) ratios; and with PRESS technique (n = 7) demonstrated lactate peak (57.1%). Macroscopic magnetic resonance imaging findings in association with biochemical features of medulloblastomas have been useful in the differentiation among the most frequent posterior fossa tumors. (author)

  1. Superresolution Imaging Using Resonant Multiples

    KAUST Repository

    Guo, Bowen

    2017-12-22

    A resonant multiple is defined as a multiple reflection that revisits the same subsurface location along coincident reflection raypaths. We show that resonant first-order multiples can be migrated with either Kirchhoff or wave-equation migration methods to give images with approximately twice the spatial resolution compared to post-stack primary-reflection images. A moveout-correction stacking method is proposed to enhance the signal-to-noise ratios (SNRs) of the resonant multiples before superresolution migration. The effectiveness of this procedure is validated by synthetic and field data tests.

  2. Superresolution Imaging Using Resonant Multiples

    KAUST Repository

    Guo, Bowen; Schuster, Gerard T.

    2017-01-01

    A resonant multiple is defined as a multiple reflection that revisits the same subsurface location along coincident reflection raypaths. We show that resonant first-order multiples can be migrated with either Kirchhoff or wave-equation migration methods to give images with approximately twice the spatial resolution compared to post-stack primary-reflection images. A moveout-correction stacking method is proposed to enhance the signal-to-noise ratios (SNRs) of the resonant multiples before superresolution migration. The effectiveness of this procedure is validated by synthetic and field data tests.

  3. Magnetic resonance imaging of the central nervous system

    International Nuclear Information System (INIS)

    Brant-Zawadzki, M.; Norman, D.

    1987-01-01

    This book presents the papers on technological advancement and diagnostic uses g magnetic resonance imaging. A comparative evaluation with computerized tomography is presented. Topics covered are imaging principles g magnetic resonance;instrumentation of magnetic resonance (MR);pathophysiology;quality and limitations g images;NMR imaging of brain and spinal cord;MR spectroscopy and its applications;neuroanatomy;Congenital malformations of brain and MR imaging;planning g MR imaging of spine and head and neck imaging

  4. Modern cartilage imaging of the ankle; Moderne Knorpelbildgebung des Sprunggelenks

    Energy Technology Data Exchange (ETDEWEB)

    Weber, Marc-Andre; Wuennemann, Felix; Rehnitz, Christoph [University Hospital Heidelberg (Germany). Diagnostic and Interventional Radiology; Jungmann, Pia M. [Technical Univ. Munich (Germany). Radiology; Kuni, Benita [Ortho-Zentrum Karlsruhe (Germany). Orthopedics and Trauma Surgery

    2017-10-15

    Talar osteochondral lesions are an important risk factor for the development of talar osteoarthritis. Furthermore, osteochondral lesions might explain persistent ankle pain. Early diagnosis of accompanying chondral defects is important to establish the optimal therapy strategy and thereby delaying or preventing the onset of osteoarthritis. The purpose of this review is to explain modern cartilage imaging with emphasis of MR imaging as well as the discussion of more sophisticated imaging studies like CT-arthrography or functional MR imaging. Pubmed literature search concerning: osteochondral lesions, cartilage damage, ankle joint, talus, 2 D MR imaging, 3 D MR imaging, cartilage MR imaging, CT-arthrography, cartilage repair, microfracture, OATS, MACT. Dedicated MR imaging protocols to delineate talar cartilage and the appearance of acute and chronic osteochondral lesions were discussed. Recent developments of MR imaging, such as isotropic 3 D imaging that has a higher signal-to noise ratio when compared to 2 D imaging, and specialized imaging methods such as CT-arthrography as well as functional MR imaging were introduced. Several classifications schemes and imaging findings of osteochondral lesions that influence the conservative or surgical therapy strategy were discussed. MRI enables after surgery the non-invasive assessment of the repair tissue and the success of implantation. Key points: Modern MRI allows for highly resolved visualization of the articular cartilage of the ankle joint and of subchondral pathologies. Recent advances in MRI include 3 D isotropic ankle joint imaging, which deliver higher signal-to-noise ratios of the cartilage and less partial volume artifacts when compared with standard 2 D sequences. In case of osteochondral lesions MRI is beneficial for assessing the stability of the osteochondral fragment and for this discontinuity of the cartilage layer is an important factor. CT-arthrography can be used in case of contraindications of MRI and

  5. Slotted cage resonator for high-field magnetic resonance imaging of rodents

    Energy Technology Data Exchange (ETDEWEB)

    Marrufo, O; Vasquez, F; Solis, S E; Rodriguez, A O, E-mail: arog@xanum.uam.mx [Departamento de Ingenieria Electrica, Universidad Autonoma Metropolitana Iztapalapa, Mexico, DF 09340 (Mexico)

    2011-04-20

    A variation of the high-frequency cavity resonator coil was experimentally developed according to the theoretical frame proposed by Mansfield in 1990. Circular slots were used instead of cavities to form the coil endplates and it was called the slotted cage resonator coil. The theoretical principles were validated via a coil equivalent circuit and also experimentally with a coil prototype. The radio frequency magnetic field, B1, produced by several coil configurations was numerically simulated using the finite-element approach to investigate their performances. A transceiver coil, 8 cm long and 7.6 cm in diameter, and composed of 4 circular slots with a 15 mm diameter on both endplates, was built to operate at 300 MHz and quadrature driven. Experimental results obtained with the slotted cage resonator coil were presented and showed very good agreement with the theoretical expectations for the resonant frequency as a function of the coil dimensions and slots. A standard birdcage coil was also built for performance comparison purposes. Phantom images were then acquired to compute the signal-to-noise ratio of both coils showing an important improvement of the slotted cage coil over the birdcage coil. The whole-body images of the mouse were also obtained showing high-quality images. Volume resonator coils can be reliably built following the physical principles of the cavity resonator design for high-field magnetic resonance imaging applications of rodents.

  6. Infrapatellar plica of the knee: Revisited with MR arthrographies undertaken in the knee flexion position mimicking operative arthroscopic posture

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young Han; Song, Ho-Taek; Kim, Sungjun [Department of Radiology and Research Institute of Radiological Science, Yonsei University College of Medicine, 250 Seongsanno, Seodaemun-gu, Seoul 120-752 (Korea, Republic of); Kim, Sung-Jae [Department of Orthopedic Surgery and Arthroscopic Surgery Unit, Yonsei University College of Medicine (Korea, Republic of); Suh, Jin-Suck, E-mail: jss@yuhs.ac [Department of Radiology and Research Institute of Radiological Science, Yonsei University College of Medicine, 250 Seongsanno, Seodaemun-gu, Seoul 120-752 (Korea, Republic of)

    2012-10-15

    Purpose: To describe the appearance of the infrapatellar plica (IPP) on magnetic resonance arthrography (MRA) taken in 70° knee flexion, corresponding to the arthroscopic posture. Materials and methods: Twenty-two patients (23 knee joints) who underwent MRA with 70° knee flexion were enrolled. All patients underwent MRA with 70° knee flexion to simulate operative arthroscopy. The images included fat-suppressed T1-weighted spin echo axial, sagittal, and coronal images. The visualization and morphology of the IPP were retrospectively assessed by two musculoskeletal radiologists. Results: The IPP was demonstrated in 78.3% (n = 18/23) and was best visualized on the sagittal section through the intercondylar notch. The IPP manifested as a linear hypointense structure with variable thicknesses. The intercondylar component was delineated clearly, arising from the anterior intercondylar notch in parallel with the ACL and curving gently downward to attach to the infrapatellar fat pad. On the other hand, the Hoffa's fat pad component was not depicted clearly. The morphology of the IPP was either a separate type (60.9%) or a split type (17.4%). Conclusion: The IPPs can be visualized with a high rate of detection and various morphologic appearances must be appreciated under the review of a flexed knee MRA.

  7. Magnetic resonance imaging of the fetal brain.

    Science.gov (United States)

    Tee, L Mf; Kan, E Yl; Cheung, J Cy; Leung, W C

    2016-06-01

    This review covers the recent literature on fetal brain magnetic resonance imaging, with emphasis on techniques, advances, common indications, and safety. We conducted a search of MEDLINE for articles published after 2010. The search terms used were "(fetal OR foetal OR fetus OR foetus) AND (MR OR MRI OR [magnetic resonance]) AND (brain OR cerebral)". Consensus statements from major authorities were also included. As a result, 44 relevant articles were included and formed the basis of this review. One major challenge is fetal motion that is largely overcome by ultra-fast sequences. Currently, single-shot fast spin-echo T2-weighted imaging remains the mainstay for motion resistance and anatomical delineation. Recently, a snap-shot inversion recovery sequence has enabled robust T1-weighted images to be obtained, which is previously a challenge for standard gradient-echo acquisitions. Fetal diffusion-weighted imaging, diffusion tensor imaging, and magnetic resonance spectroscopy are also being developed. With multiplanar capabilities, superior contrast resolution and field of view, magnetic resonance imaging does not have the limitations of sonography, and can provide additional important information. Common indications include ventriculomegaly, callosum and posterior fossa abnormalities, and twin complications. There are safety concerns about magnetic resonance-induced heating and acoustic damage but current literature showed no conclusive evidence of deleterious fetal effects. The American College of Radiology guideline states that pregnant patients can be accepted to undergo magnetic resonance imaging at any stage of pregnancy if risk-benefit ratio to patients warrants that the study be performed. Magnetic resonance imaging of the fetal brain is a safe and powerful adjunct to sonography in prenatal diagnosis. It can provide additional information that aids clinical management, prognostication, and counselling.

  8. Magnetic Resonance Imaging (MRI): Brain (For Parents)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Magnetic Resonance Imaging (MRI): Brain KidsHealth / For Parents / Magnetic Resonance Imaging (MRI): Brain What's in this article? What ...

  9. Magnetic resonance imaging (MRI)

    OpenAIRE

    Takavar A

    1993-01-01

    Basic physical principles of nuclear magnetic resonance imaging (N.M.R.I), a nonionizing medical imaging technique, are described. Principles of NMRI with other conventional imaging methods, ie, isotope scanning, ultrasonography and radiography have been compared. T1 and T2 and spin density (S.D.) factors and different image construction techniques based on their different combinations is discussed and at the end physical properties of some N.M.R images is mentioned.

  10. Magnetic resonance imaging of the elbow. Part I: Normal anatomy, imaging technique, and osseous abnormalities

    International Nuclear Information System (INIS)

    Kijowski, Richard; Tuite, Michael; Sanford, Matthew

    2004-01-01

    Part I of this comprehensive review on magnetic resonance imaging of the elbow discusses normal elbow anatomy and the technical factors involved in obtaining high-quality magnetic resonance images of the elbow. Part I also discusses the role of magnetic resonance imaging in evaluating patients with osseous abnormalities of the elbow. With proper patient positioning and imaging technique, magnetic resonance imaging can yield high-quality multiplanar images which are useful in evaluating the osseous structures of the elbow. Magnetic resonance imaging can detect early osteochondritis dissecans of the capitellum and can be used to evaluate the size, location, stability, and viability of the osteochondritis dissecans fragment. Magnetic resonance imaging can detect early stress injury to the proximal ulna in athletes. Magnetic resonance imaging can detect radiographically occult fractures of the elbow in both children and adults. Magnetic resonance imaging is also useful in children to further evaluate elbow fractures which are detected on plain-film radiographs. (orig.)

  11. Functional magnetic resonance imaging by visual stimulation

    International Nuclear Information System (INIS)

    Nishimura, Yukiko; Negoro, Kiyoshi; Morimatsu, Mitsunori; Hashida, Masahiro

    1996-01-01

    We evaluated functional magnetic resonance images obtained in 8 healthy subjects in response to visual stimulation using a conventional clinical magnetic resonance imaging system with multi-slice spin-echo echo planar imaging. Activation in the visual cortex was clearly demonstrated by the multi-slice experiment with a task-related change in signal intensity. In addition to the primary visual cortex, other areas were also activated by a complicated visual task. Multi-slice spin-echo echo planar imaging offers high temporal resolution and allows the three-dimensional analysis of brain function. Functional magnetic resonance imaging provides a useful noninvasive method of mapping brain function. (author)

  12. Digital subtraction arthrography in preoperative evaluation of painful total hip arthroplasty

    International Nuclear Information System (INIS)

    Ginai, A.Z.; Biezen, F.C. van; Kint, P.A.M.; Oei, H.Y.; Hop, W.C.J.

    1996-01-01

    Digital subtraction arthrograms, scintigrams and plain radiographs of 70 consecutive patients who underwent revision hip arthroplasty were scored individually and in masked fashion for the presence or absence of features indicating loosening of femoral and/or acetabular components. The operative findings acted as the gold standard. Digital subtraction arthrography was best for predicting a loose acetabular component, while no significant additional predictive value was found for plain radiographs and scintigraphy. Digital subtraction arthrography was also the most important modality for predicting a loose femoral component, while the plain radiograph was of significant additional value and scintigraphy was of no additional value on multivariate analysis. (orig./MG)

  13. Glenohumeral position during CT arthrography with arthroscopic correlation: optimization of diagnostic yield

    Energy Technology Data Exchange (ETDEWEB)

    Simeone, F.J.; Gill, Corey M.; Torriani, Martin; Bredella, Miriam A. [Massachusetts General Hospital and Harvard Medical School, Division of Musculoskeletal Imaging and Intervention, Boston, MA (United States); Taneja, Atul K. [Hospital Israelita Albert Einstein, Hospital do Coracao (HCor) and Teleimagem, Musculoskeletal Imaging, Sao Paulo, SP (Brazil)

    2017-06-15

    To evaluate the diagnostic yield of two acquisitions of single-contrast CT arthrography (CTA) of the shoulder in internal, neutral, or external glenohumeral rotation with arthroscopic correlation. The CT study was obtained using two acquisitions (first the humerus positioned in maximum tolerated external rotation with the arm along the body and the second with the humerus in internal rotation with the palm placed flat on the table). Two independent readers blinded to the arthroscopic results evaluated the CTA images for labral tears, glenoid bone loss/fractures, and cartilage loss. For each CTA acquisition, sensitivity and specificity for detection of the aforementioned pathology were assessed. Inter-reader agreement was quantified by weighted k statistics. Sensitivity and specificity for detecting anteroinferior or posterior labral tears was highest with neutral rotation (sensitivity 91-100%, specificity 61-100%). For glenoid fracture, sensitivity (67%) was highest with external rotation and specificity (100%) was highest with internal rotation. For cartilage loss, sensitivity (64%) and specificity (89%) was highest with external rotation and neutral rotation, respectively. Neutral rotation showed high sensitivity and specificity for glenoid fractures and cartilage loss. Inter-reader agreement ranged from fair to very good. Neutral glenohumeral position in shoulder CT arthrography was adequately sensitive and specific for the detection of intra-articular pathology, avoiding the use of more than one acquisition. (orig.)

  14. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... it is useful to bring that to the attention of the scheduler before the exam and bring ... Image Gallery Magnetic Resonance Imaging (MRI) procedure View full size with caption Pediatric Content Some imaging tests ...

  15. Magnetic resonance imaging in clinically-definite multiple sclerosis

    International Nuclear Information System (INIS)

    Noakes, J.B.; Herkes, G.K.; Frith, J.A.

    1990-01-01

    Forty-two patients with clinically-definite multiple sclerosis were examined by magnetic resonance imaging using a 1.5-T instrument. Magnetic resonance imaging detected an abnormality in 90% of patients. In four patients, no lesions were demonstrated. The number, size and site of the lesions by magnetic resonance imaging were compared with the patients' clinical status and other variables. The Kurtzke disability status scale score increased in patients with corpus callosum atrophy, brainstem and basal ganglia lesions, and correlated with the total number of lesions. No correlation was shown between the findings of magnetic resonance imaging and disease duration, age, sex or pattern-reversal visual-evoked potentials. The variety of magnetic resonance images that could be obtained in patients with clinically-definite multiple sclerosis is highlighted. 24 refs., 8 figs., 1 tab

  16. Magnetic resonance imaging

    International Nuclear Information System (INIS)

    Sigal, R.

    1988-01-01

    This book is an introduction to magnetic resonance imaging (MRI). The basic principles for the interpretation of MR images are developed. The book is divided into five chapters: introduction, tissue, parameters, acquisition parameters, contribution to diagnosis, and practical management of an MR examination. Eight exercises allow the reader to test the knowledge he has acquired. Signal localization and MR artefacts are reviewed in an appendix

  17. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... As the hydrogen atoms return to their usual alignment, they emit different amounts of energy that vary ... story about radiology? Share your patient story here Images × Image Gallery Magnetic Resonance Imaging (MRI) procedure View ...

  18. Magnetic resonance imaging (MRI

    Directory of Open Access Journals (Sweden)

    Takavar A

    1993-04-01

    Full Text Available Basic physical principles of nuclear magnetic resonance imaging (N.M.R.I, a nonionizing medical imaging technique, are described. Principles of NMRI with other conventional imaging methods, ie, isotope scanning, ultrasonography and radiography have been compared. T1 and T2 and spin density (S.D. factors and different image construction techniques based on their different combinations is discussed and at the end physical properties of some N.M.R images is mentioned.

  19. Imaging of juvenile spondyloarthritis. Part II: Ultrasonography and magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Iwona Sudoł-Szopińska

    2017-09-01

    Full Text Available Juvenile spondyloarthropathies are mainly manifested by symptoms of peripheral arthritis and enthesitis. Early involvement of sacroiliac joints and spine is exceptionally rare in children; this usually happens in adulthood. Conventional radiographs visualize late inflammatory lesions. Early diagnosis is possible with the use of ultrasonography and magnetic resonance imaging. The first part of the article presented classifications and radiographic presentation of juvenile spondyloarthropathies. This part discusses changes seen on ultrasonography and magnetic resonance imaging. In patients with juvenile spondyloarthropathies, these examinations are conducted to diagnose inflammatory lesions in peripheral joints, tendon sheaths, tendons and bursae. Moreover, magnetic resonance also shows subchondral bone marrow edema, which is considered an early sign of inflammation. Ultrasonography and magnetic resonance imaging do not show specific lesions for any rheumatic disease. Nevertheless, they are conducted for early diagnosis, treatment monitoring and identifying complications. This article presents a spectrum of inflammatory changes and discusses the diagnostic value of ultrasonography and magnetic resonance imaging.

  20. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... for Brain Tumors Radiation Therapy for Head and Neck Cancer Others : American Stroke Association National Stroke Association ... MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain Tumor Treatment Magnetic Resonance Imaging ( ...

  1. Functional Magnetic Resonance Imaging

    Science.gov (United States)

    Voos, Avery; Pelphrey, Kevin

    2013-01-01

    Functional magnetic resonance imaging (fMRI), with its excellent spatial resolution and ability to visualize networks of neuroanatomical structures involved in complex information processing, has become the dominant technique for the study of brain function and its development. The accessibility of in-vivo pediatric brain-imaging techniques…

  2. Magnetic resonance imaging findings compared with histological findings of the labrum in hip osteoarthritis

    International Nuclear Information System (INIS)

    Kanezaki, Shiho; Nakamura, Shigeru; Matsushita, Takashi; Yamamoto, Asako; Osawa, Marie

    2015-01-01

    Patients with disorders such as acetabular dysplasia or femoroacetabular impingement are at risk of developing hip osteoartbritis. Assessment of the cartilage and labrum in the hip joint based on magnetic resonance imaging (MRI) has been challenging because of the low signal-to-noise ratio (SNR) due to its deep location, ball and socket structure, and small volume of those structures compared with the whole joint size. To achieve better imaging assessment, direct MR. arthrography (d-MRA) and other techniques such as T2* mapping, T2 mapping, Tlrho, and delayed gadolinium-enhanced MRI (dGEMRIC) have been developed along with the increasing use of high-field MRI. In patients with no apparent osteoarthritic changes such as joint space narrowing or osteophyte and subchondral cyst formation on radiographs, these techniques can detect early cartilage or labral damage. A recently developed semiquantitative MRI-based scoring system for hip osteoarthritis includes evaluation of the labrum, and its application as a potential therapeutic monitoring tool is anticipated. The labrum shows pathological changes such as macroscopic hypertrophy and histological degeneration in hip osteoartbritis, but the pathological background is not well understood when evaluated by MRI. Kubo et al. compared radial MRI findings with histological changes of the labrum in ll hips with osteoarthritis using 1.5-T MRJ and found that fibrous separation and mucoid deposition occurred in the labrum with a ''diffuse high signal'' or ''obscure'' pattern. However, to the best of our knowledge, no studies have demonstrated a correlation between MRI fmdings and histological evidence of the severity of degeneration of the labrum. We hypothesized that radially reconstructed images of the acetabular labrum acquired by 3-T MRI can depict degenerative changes of the labrum. In this study, we sought to determine the correlation between MRI and histological findings of the

  3. Magnetic resonance imaging findings compared with histological findings of the labrum in hip osteoarthritis

    Energy Technology Data Exchange (ETDEWEB)

    Kanezaki, Shiho; Nakamura, Shigeru; Matsushita, Takashi [Teikyo University School of Medicine, Department of Orthopaedic Surgery, Itabashi-ku, Tokyo (Japan); Yamamoto, Asako; Osawa, Marie [Teikyo University School of Medicine, Department of Radiology, Itabashi-ku, Tokyo (Japan)

    2015-06-01

    Patients with disorders such as acetabular dysplasia or femoroacetabular impingement are at risk of developing hip osteoartbritis. Assessment of the cartilage and labrum in the hip joint based on magnetic resonance imaging (MRI) has been challenging because of the low signal-to-noise ratio (SNR) due to its deep location, ball and socket structure, and small volume of those structures compared with the whole joint size. To achieve better imaging assessment, direct MR. arthrography (d-MRA) and other techniques such as T2* mapping, T2 mapping, Tlrho, and delayed gadolinium-enhanced MRI (dGEMRIC) have been developed along with the increasing use of high-field MRI. In patients with no apparent osteoarthritic changes such as joint space narrowing or osteophyte and subchondral cyst formation on radiographs, these techniques can detect early cartilage or labral damage. A recently developed semiquantitative MRI-based scoring system for hip osteoarthritis includes evaluation of the labrum, and its application as a potential therapeutic monitoring tool is anticipated. The labrum shows pathological changes such as macroscopic hypertrophy and histological degeneration in hip osteoartbritis, but the pathological background is not well understood when evaluated by MRI. Kubo et al. compared radial MRI findings with histological changes of the labrum in ll hips with osteoarthritis using 1.5-T MRJ and found that fibrous separation and mucoid deposition occurred in the labrum with a ''diffuse high signal'' or ''obscure'' pattern. However, to the best of our knowledge, no studies have demonstrated a correlation between MRI fmdings and histological evidence of the severity of degeneration of the labrum. We hypothesized that radially reconstructed images of the acetabular labrum acquired by 3-T MRI can depict degenerative changes of the labrum. In this study, we sought to determine the correlation between MRI and histological findings of the

  4. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... work? Unlike conventional x-ray examinations and computed tomography (CT) scans, MRI does not utilize ionizing radiation. Instead, ... Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's (Pediatric) CT (Computed Tomography) Magnetic Resonance Imaging (MRI) Safety Contrast Materials Children ...

  5. 76 FR 58281 - Magnetic Resonance Imaging Safety; Public Workshop

    Science.gov (United States)

    2011-09-20

    ...] Magnetic Resonance Imaging Safety; Public Workshop AGENCY: Food and Drug Administration, HHS. ACTION... announcing a public workshop entitled: ``Magnetic Resonance Imaging (MRI) Safety Public Workshop.'' The purpose of the public workshop is to discuss factors affecting the safe use of magnetic resonance imaging...

  6. Functional magnetic resonance imaging of the primary motor cortex ...

    Indian Academy of Sciences (India)

    Unknown

    Abbreviations used: BOLD, Blood oxygenation level dependent; CBF, cerebral blood flow; fMRI, functional magnetic resonance imaging; EPI, eco-planar imaging; FOV, field of view; MRI, Magnetic resonance imaging; MRS, magnetic resonance spectroscopy;. PET, position emission tomography; rCBF, regional cerebral ...

  7. Magnetic resonance imaging of infectious myositis

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Ji Young; Kim, Jee Young; Kim, Sang Heum; Jung, Youn Ju; Cha, Eun Suk; Park, Joung Mi; Park, Young Ha [The Catholic Univ., College of Medicine, Suwon (Korea, Republic of)

    1998-09-01

    To describe the findings of magnetic resonance imaging in infectious myositis and to determine their value for differentiation between ruberculous and bacterial myositis. Magnetic resonance images of ten proven cases of infectious myositis (five tuberculous and five bacterial) were retrospectively reviewed in the light of clinical and laboratory findings. On the basis of magnetic resonance images, signal intensity of the mass, the presence or absence of an abscess, signal intensity of the peripheral wall, patterns of contrast enhancement, and associated findings were evaluated. Compared with those of bacterial myositis, the symptoms of tuberculous myositis lasted longer but there were no difinite local inflammatory signs. In three of five cases of bacterial myositis there were specific medical records;trauma in two cases and systemic lupus erythematosus in one. All tuberculous myositis cases involved a single muscle, but bacterial myositis affected multipe muscles in three cases(60%). All but one case showed a mass in the involved muscles. In one bacterial case, there was diffuse swelling in the involved muscle. On T1-weighted images, eight infectious cases showed low signal intensity;two, of the bactrerial type, showed subtle increased signal intensity. all cases demonstrated high signal intensity on t2-weighted images. The signal intensity of peripheral wall was slightly increased on T1-weighted images, but low on T2-weighted. In four cases there was associated cellulitis, and in one case each, adjacent joint effusion and deep vein thrombosis were seen. After gadolinium infusion, peripheral rim enhancement was noted in nine cases and heterogeneous enhancement in one. After magnetic resonance imaging of infectious myositis, the characteristic finding was an abscessed lesion, with the peripheral wall showing high signal intensity on T1-weighted images and low signal intensity on T2 weighted. Although we found it difficult to differentiate bacterial from tuberculous

  8. Magnetic resonance imaging of infectious myositis

    International Nuclear Information System (INIS)

    Yun, Ji Young; Kim, Jee Young; Kim, Sang Heum; Jung, Youn Ju; Cha, Eun Suk; Park, Joung Mi; Park, Young Ha

    1998-01-01

    To describe the findings of magnetic resonance imaging in infectious myositis and to determine their value for differentiation between ruberculous and bacterial myositis. Magnetic resonance images of ten proven cases of infectious myositis (five tuberculous and five bacterial) were retrospectively reviewed in the light of clinical and laboratory findings. On the basis of magnetic resonance images, signal intensity of the mass, the presence or absence of an abscess, signal intensity of the peripheral wall, patterns of contrast enhancement, and associated findings were evaluated. Compared with those of bacterial myositis, the symptoms of tuberculous myositis lasted longer but there were no difinite local inflammatory signs. In three of five cases of bacterial myositis there were specific medical records;trauma in two cases and systemic lupus erythematosus in one. All tuberculous myositis cases involved a single muscle, but bacterial myositis affected multipe muscles in three cases(60%). All but one case showed a mass in the involved muscles. In one bacterial case, there was diffuse swelling in the involved muscle. On T1-weighted images, eight infectious cases showed low signal intensity;two, of the bactrerial type, showed subtle increased signal intensity. all cases demonstrated high signal intensity on t2-weighted images. The signal intensity of peripheral wall was slightly increased on T1-weighted images, but low on T2-weighted. In four cases there was associated cellulitis, and in one case each, adjacent joint effusion and deep vein thrombosis were seen. After gadolinium infusion, peripheral rim enhancement was noted in nine cases and heterogeneous enhancement in one. After magnetic resonance imaging of infectious myositis, the characteristic finding was an abscessed lesion, with the peripheral wall showing high signal intensity on T1-weighted images and low signal intensity on T2 weighted. Although we found it difficult to differentiate bacterial from tuberculous

  9. Musculoskeletal applications of magnetic resonance imaging: Council on Scientific Affairs

    International Nuclear Information System (INIS)

    Harms, S.E.; Fisher, C.F.; Fulmer, J.M.

    1989-01-01

    Magnetic resonance imaging provides superior contrast, resolution, and multiplanar imaging capability, allowing excellent definition of soft-tissue and bone marrow abnormalities. For these reasons, magnetic resonance imaging has become a major diagnostic imaging method for the evaluation of many musculoskeletal disorders. The applications of magnetic resonance imaging for musculoskeletal diagnosis are summarized and examples of common clinical situations are given. General guidelines are suggested for the musculoskeletal applications of magnetic resonance imaging

  10. Imaging by magnetic resonance

    International Nuclear Information System (INIS)

    Duroure, J.F.; Serpolay, H.; Vallens, D.

    1995-01-01

    Here are described the advanced technology for nuclear magnetic resonance imaging: reduction of acquisition times, and rebuilding times, images quality improvement. The tendency is to open the machines at low and middle field, on a market being at 10% of NMR I sales, with economical, scientifical and ergonomic reasons broadly developed by constructors

  11. Pulse sequences for contrast-enhanced magnetic resonance imaging

    International Nuclear Information System (INIS)

    Graves, Martin J.

    2007-01-01

    The theory and application of magnetic resonance imaging (MRI) pulse sequences following the administration of an exogenous contrast agent are discussed. Pulse sequences are categorised according to the contrast agent mechanism: changes in proton density, relaxivity, magnetic susceptibility and resonant frequency shift. Applications in morphological imaging, magnetic resonance angiography, dynamic imaging and cell labelling are described. The importance of optimising the pulse sequence for each application is emphasised

  12. Magnetic resonance imaging- physical principles and clinical application

    International Nuclear Information System (INIS)

    Tavri, Omprakash J.

    1996-01-01

    The advances in equipment and knowledge related to radiology are occurring at an astonishingly rapid rate. On November 8, 1895, William Conrad Roentgen discovered x-rays. In 1972, Godfrey Hounsfield and George Ambrose introduced computec tomography at a meeting of the British Institute of Radiology. In the same year, Paul Lauterbur published the idea of spatially resolving nuclear magnetic resonance samples, naming it zeugmatography. In 1977, Waldo Hinshaw and co-workers published a magnetic resonance image of a human hand and wrist, and by 1981 several centres were obtaining clinical magnetic resonance (MR) images. In a very short time, magnetic resonance imaging (MRI) has gained acceptance as a clinically useful imaging tool. (author)

  13. Shoulder imaging with MR, US, arthography, and arthoscopy

    International Nuclear Information System (INIS)

    Drace, J.; Resendes, M.; Pyka, W.

    1989-01-01

    To date, the true efficacies of shoulder imaging modalities remain uncertain, as no prospective study controlling for significant selection bias has been reported. A minimum of 25 double-blind examinations now have definitive confirmation, not selected by the imaging modalities. The images and interpretations were sealed in an envelope and blinded from the arthroscopist for initial arthroscopy, but second-look arthroscopy, and in some cases open surgery, was performed after unsealing the envelope. Therefore, negative and positive cases were equivalently tested. To date, MR imaging and US remain equally sensitive (85%) for detection of rotator cuff tears, but the combination is more sensitive (90%), and both are more sensitive than arthrography. Arthrography increased specificity when MR imaging and US in combination appear useful for diagnosis of biceps tendinitis

  14. Labral and cartilage abnormalities in young patients with hip pain: accuracy of 3-Tesla indirect MR arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Petchprapa, Catherine N.; Rybak, Leon D. [NYU Langone Medical Center-Hospital for Joint Diseases, Department of Radiology, New York, NY (United States); Dunham, Kevin S.; Recht, Michael P. [NYU Langone Medical Center, Department of Radiology, New York, NY (United States); Lattanzi, Riccardo [NYU Langone Medical Center, The Bernard and Irene Schwartz Center for Biomedical Imaging, New York, NY (United States)

    2015-01-15

    Assess the diagnostic accuracy of 3-T indirect magnetic resonance arthrography (iMRA) for hip cartilage and labral pathology detection using arthroscopy as the reference standard and compare it to the published performance of direct magnetic resonance arthrography (dMRA). Between 2009 and 2011, 290 patients suspected of having femoroacetabular impingement underwent iMRA. Our study group consisted of 41 of these patients (17 males, mean age 35 years; 24 females, mean age 33 years) who did not have a prior history of hip surgery and who subsequently underwent arthroscopy. Two experienced musculoskeletal radiologists separately evaluated the randomized and anonymized studies for the presence and quadrant location of labral and cartilage pathology. These recorded data were compared to arthroscopic reports. Forty-one patients had labral pathology, 34 patients had acetabular and 5 patients had femoral cartilage pathology at arthroscopy. Sensitivity, specificity, accuracy, negative- and positive-predictive values for labral lesion detection were respectively 98, 99, 99, 99 and 98 %; for acetabular cartilage lesion detection they were 69, 98, 89, 87 and 95 %; for femoral cartilage lesion detection they were 69, 95, 93 and 39 %. Sensitivities of iMRA by quadrant (anteroinferior, anterosuperior, posteroinferior, posterosuperior) for the labrum were 100.0, 95.0, NA and 85.7 %, for acetabular cartilage were NA, 58.8, NA and 39.5 % and for femoral cartilage were 50.0, 33.3, 75.0 and 75.0 %. NA indicates results not available because of the absence of findings in those quadrants. Specificities of iMRA by quadrant (anteroinferior, anterosuperior, posteroinferior, posterosuperior) for the labrum (95.0, 100.0, 95.1, 67.5 %), acetabular (100.0, 85.7, 92.6, 79.5 %) and femoral cartilage (100.0, 94.7, 96.2, 85.9 %). iMRA at 3 T is accurate in detecting labral pathology suggesting that it is a viable alternative to dMRA. (orig.)

  15. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - ...

  16. Far-field super-resolution imaging of resonant multiples

    KAUST Repository

    Guo, Bowen

    2016-05-20

    We demonstrate for the first time that seismic resonant multiples, usually considered as noise, can be used for super-resolution imaging in the far-field region of sources and receivers. Tests with both synthetic data and field data show that resonant multiples can image reflector boundaries with resolutions more than twice the classical resolution limit. Resolution increases with the order of the resonant multiples. This procedure has important applications in earthquake and exploration seismology, radar, sonar, LIDAR (light detection and ranging), and ultrasound imaging, where the multiples can be used to make high-resolution images.

  17. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... by the interpreting radiologist. Frequently, the differentiation of abnormal (diseased) tissue from normal tissues is better with ... Tumor Treatment Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain Tumors Images related to Magnetic ...

  18. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... it is useful to bring that to the attention of the technologist or scheduler before the exam. ... patient for magnetic resonance imaging (MRI) exam. View full size with caption Pediatric Content Some imaging tests ...

  19. MR arthrography in calcific tendinitis of the shoulder: diagnostic performance and pitfalls

    Energy Technology Data Exchange (ETDEWEB)

    Zubler, Christoph; Mengiardi, Bernard; Schmid, Marius R.; Hodler, Juerg; Pfirrmann, Christian W.A. [University Hospital Balgrist, Radiology, Zurich (Switzerland); Jost, Bernhard [University Hospital Balgrist, Orthopedic Surgery, Zurich (Switzerland)

    2007-06-15

    The purpose was to assess the diagnostic performance of MR arthrography to diagnose calcific tendinitis of the shoulder and to assess the reasons for diagnostic errors. Standard MR arthrograms of 22 patients with calcific tendinitis and 61 controls were retrospectively analyzed by two independent and blinded radiologists. All cases were consecutively collected from a database. Conventional radiographs were available in all cases serving as gold standard. The supraspinatus was involved in 16, the infraspinatus in four and the subscapularis in two patients. All diagnostic errors were analyzed by two additional readers. Reader 1 correctly detected 12 of the 22 shoulders with and 42 of the 61 shoulders without calcific tendinitis (sensitivity 0.55, specificity 0.66). The corresponding values for reader 2 were 13 of 22 and 40 of 61 cases (sensitivity 0.59, specificity 0.69). Inter-rater agreement (kappa-value) was 0.42. Small size of the calcific deposits and isointensity compared to the surrounding tissue were the most important reasons for false negative results. Normal hypointense areas within the supraspinatus tendon substance and attachment were the main reason for false positive results. In conclusion, MR arthrography is insufficient in the diagnosis of calcific tendinitis. Normal hypointense parts of the rotator cuff may mimic calcific deposits and calcifications may not be detected when they are isointense compared to the rotator cuff. Therefore, MR imaging should not be interpreted without corresponding radiographs. (orig.)

  20. MR arthrography in calcific tendinitis of the shoulder: diagnostic performance and pitfalls

    International Nuclear Information System (INIS)

    Zubler, Christoph; Mengiardi, Bernard; Schmid, Marius R.; Hodler, Juerg; Pfirrmann, Christian W.A.; Jost, Bernhard

    2007-01-01

    The purpose was to assess the diagnostic performance of MR arthrography to diagnose calcific tendinitis of the shoulder and to assess the reasons for diagnostic errors. Standard MR arthrograms of 22 patients with calcific tendinitis and 61 controls were retrospectively analyzed by two independent and blinded radiologists. All cases were consecutively collected from a database. Conventional radiographs were available in all cases serving as gold standard. The supraspinatus was involved in 16, the infraspinatus in four and the subscapularis in two patients. All diagnostic errors were analyzed by two additional readers. Reader 1 correctly detected 12 of the 22 shoulders with and 42 of the 61 shoulders without calcific tendinitis (sensitivity 0.55, specificity 0.66). The corresponding values for reader 2 were 13 of 22 and 40 of 61 cases (sensitivity 0.59, specificity 0.69). Inter-rater agreement (kappa-value) was 0.42. Small size of the calcific deposits and isointensity compared to the surrounding tissue were the most important reasons for false negative results. Normal hypointense areas within the supraspinatus tendon substance and attachment were the main reason for false positive results. In conclusion, MR arthrography is insufficient in the diagnosis of calcific tendinitis. Normal hypointense parts of the rotator cuff may mimic calcific deposits and calcifications may not be detected when they are isointense compared to the rotator cuff. Therefore, MR imaging should not be interpreted without corresponding radiographs. (orig.)

  1. Accuracy of magnetic resonance studies in the detection of chondral and labral lesions in femoroacetabular impingement: systematic review and meta-analysis.

    Science.gov (United States)

    Saied, A M; Redant, C; El-Batouty, M; El-Lakkany, M R; El-Adl, W A; Anthonissen, J; Verdonk, R; Audenaert, E A

    2017-02-16

    Several types of Magnetic resonance imaging (MRI) are commonly used in imaging of femoroacetabular impingement (FAI), however till now there are no clear protocols and recommendations for each type. The aim of this meta-analysis is to detect the accuracy of conventional magnetic resonance imaging (cMRI), direct magnetic resonance arthrography (dMRA) and indirect magnetic resonance arthrography (iMRA) in the diagnosis of chondral and labral lesions in femoroacetabular impingement (FAI). A literature search was finalized on the 17th of May 2016 to collect all studies identifying the accuracy of cMRI, dMRA and iMRA in diagnosing chondral and labral lesions associated with FAI using surgical results (arthroscopic or open) as a reference test. Pooled sensitivity and specificity with 95% confidence intervals using a random-effects meta-analysis for MRI, dMRA and iMRA were calculated also area under receiver operating characteristic (ROC) curve (AUC) was retrieved whenever possible where AUC is equivocal to diagnostic accuracy. The search yielded 192 publications which were reviewed according inclusion and exclusion criteria then 21 studies fulfilled the eligibility criteria for the qualitative analysis with a total number of 828 cases, lastly 12 studies were included in the quantitative meta-analysis. Meta-analysis showed that as regard labral lesions the pooled sensitivity, specificity and AUC for cMRI were 0.864, 0.833 and 0.88 and for dMRA were 0.91, 0.58 and 0.92. While in chondral lesions the pooled sensitivity, specificity and AUC for cMRI were 0.76, 0.72 and 0.75 and for dMRA were 0.75, 0.79 and 0.83, while for iMRA were sensitivity of 0.722 and specificity of 0.917. The present meta-analysis showed that the diagnostic test accuracy was superior for dMRA when compared with cMRI for detection of labral and chondral lesions. The diagnostic test accuracy was superior for labral lesions when compared with chondral lesions in both cMRI and dMRA. Promising results are

  2. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... As the hydrogen atoms return to their usual alignment, they emit different amounts of energy that vary ... story about radiology? Share your patient story here Images × Image Gallery Radiologist prepping patient for magnetic resonance ...

  3. Magnetic Resonance Imaging (MRI): Lumbar Spine (For Parents)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Magnetic Resonance Imaging (MRI): Lumbar Spine KidsHealth / For Parents / Magnetic Resonance Imaging (MRI): Lumbar Spine What's in this article? ...

  4. Role of chelates in magnetic resonance imaging studies

    Directory of Open Access Journals (Sweden)

    Tripathi Laxmi

    2009-01-01

    Full Text Available Imaging studies are tests performed with a variety of techniques that produce pictures of the inside of a patient′s body. Magnetic resonance imaging (MRI is an imaging technique based on the principles of nuclear magnetic resonance. MRI uses a powerful magnetic field, radio waves, and a computer to produce detailed pictures of organs, soft tissues, bone, and virtually all other internal body structures. Chelates have a wide application in such imaging techniques. Chelates in imaging studies are used alone as radioactive agents or conjugated to monoclonal antibodies or to DNA as radioactive agents. Technetium chelates and gadolinium chelates are being widely used as magnetic resonance contrast media.

  5. Radiographic anatomy and technique for arthrography of the cubital joint in clinically normal dogs

    International Nuclear Information System (INIS)

    Lowry, J.E.; Carpenter, L.G.; Park, R.D.; Steyn, P.F.; Schwarz, P.D.

    1993-01-01

    A technique for arthrography of the cubital joint in clinically normal large-breed dogs was developed with the objective of improving visualization of the articular margin of the medial coronoid process. A lateral approach to the cubital joint for injection of contrast medium was selected. Arthrography of 24 cubital joints was performed by using 14 dogs. Twelve combinations of iodinated contrast medium, consisting of various concentrations (3) and volumes (4), were used. Two sets of arthrograms for each of the 12 combinations of contrast medium were obtained. Five radiographic views were used for each set. All arthrograms were examined by 3 evaluators, and each articular surface received a numerical rating for how well it could be seen in each view. Results of the evaluation indicated that low volumes of contrast medium were preferable to high volumes, with 2 ml providing the best visualization. Concentration of iodine seemed less important than did volume. The numerical ratings also indicated that the articular margin of the coronoid process was clearly observed a maximum of only 24% of the time on a slightly supinated mediolateral projection. The articular margins of the head of the radius, trochlea humeri, and trochlear notch were well visualized > 90% of the time. Arthrography of the cubital joint was technically easy to perform, and complications were not encountered, but arthrographic anatomy of the cubital joint is complex. Potential uses for arthrography of the cubital joint include diagnosis of osteochondrosis, intraarticular fragments, and joint capsule ruptures

  6. Double-contrast arthrography in recurrent dislocation of the shoulder

    International Nuclear Information System (INIS)

    Faletti, C.; Vassoney, P.F.; Indemini, E.; Clerico, P.

    1988-01-01

    One hundred and ninety-three shoulder arthrographies were performed between 1979 and 1985 on patients affected by recurrent dislocations. The diagnostic doubt was cleared up in 162 cases (83%). Athrographic diagnosis was confirmed by pathological findings in 92% of the patients who underwent surgery. The double-contrast technique under local anaesthesia with anterior access is suggested, since it allows several arthrograms in different projections. Thus, an analytic study of the articular damage can be carried out. The patterns of each projection are briefly shown. Revision of case histories points out that: a) the use of arthrography should always be assessed on a clinical-radiological basis for each patients; b) there is no doubt as to the usefulness of this examination as a direct means of exploration, as far as the articular damage is concerned, not only as an aid to future surgery, but also in the follow-up of the results of the treatment in the long run

  7. Magnetic resonance imaging in the evaluation of periosteal reactions

    Energy Technology Data Exchange (ETDEWEB)

    Nogueira-Barbosa, Marcello Henrique; Trad, Clovis Simao; Muglia, Valdair Francisco; Elias Junior, Jorge; Simao, Marcelo Novelino, E-mail: marcello@fmrp.usp.b [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Centro de Ciencias das Imagens e Fisica Medica; Sa, Jose Luiz de [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Hospital das Clinicas; Oliveira, Rodrigo Cecilio Vieira de [Clinica de Diagnostico por Imagem Tomoson, Aracatuba, SP (Brazil); Engel, Edgard Eduard [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Dept. de Biomecanica, Medicina e Reabilitacao do Aparelho Locomotor

    2010-07-15

    The objective of the present essay was to encourage a careful evaluation of periosteal reactions on magnetic resonance images. The initial approach to bone lesions is made by conventional radiography and, based on the imaging findings, periosteal reactions are classified into classical subtypes. Although magnetic resonance imaging is considered as the gold standard for local staging of bone tumors, the utilization of such method in the study of periosteal reactions related to focal bone lesions has been poorly emphasized, with relatively few studies approaching this subject. The literature review revealed a study describing an experimental animal model of osteomyelitis suggesting that magnetic resonance imaging is superior to other imaging methods in the early identification of periosteal reactions. Another study has suggested a good correlation between conventional radiography and magnetic resonance imaging in the identification and classification of periosteal reactions in cases of osteosarcoma. The present essay illustrates cases of periosteal reactions observed at magnetic resonance imaging in correlation with findings of conventional radiography or other imaging methods. (author)

  8. Magnetic resonance imaging in the evaluation of periosteal reactions

    International Nuclear Information System (INIS)

    Nogueira-Barbosa, Marcello Henrique; Trad, Clovis Simao; Muglia, Valdair Francisco; Elias Junior, Jorge; Simao, Marcelo Novelino; Engel, Edgard Eduard

    2010-01-01

    The objective of the present essay was to encourage a careful evaluation of periosteal reactions on magnetic resonance images. The initial approach to bone lesions is made by conventional radiography and, based on the imaging findings, periosteal reactions are classified into classical subtypes. Although magnetic resonance imaging is considered as the gold standard for local staging of bone tumors, the utilization of such method in the study of periosteal reactions related to focal bone lesions has been poorly emphasized, with relatively few studies approaching this subject. The literature review revealed a study describing an experimental animal model of osteomyelitis suggesting that magnetic resonance imaging is superior to other imaging methods in the early identification of periosteal reactions. Another study has suggested a good correlation between conventional radiography and magnetic resonance imaging in the identification and classification of periosteal reactions in cases of osteosarcoma. The present essay illustrates cases of periosteal reactions observed at magnetic resonance imaging in correlation with findings of conventional radiography or other imaging methods. (author)

  9. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... of which shows a thin slice of the body. The images can then be studied from different angles by ... about radiology? Share your patient story here Images ... Articles and Media Catheter Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's ( ...

  10. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. MRI ...

  11. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. MRI ...

  12. Normal perinatal and paediatric postmortem magnetic resonance imaging appearances

    Energy Technology Data Exchange (ETDEWEB)

    Arthurs, Owen J. [Department of Radiology, Great Ormond Street Hospital for Children NHS Foundation Trust, London (United Kingdom); UCL Institute of Child Health, London (United Kingdom); Barber, Joy L. [Department of Radiology, Great Ormond Street Hospital for Children NHS Foundation Trust, London (United Kingdom); Taylor, Andrew M. [Cardiorespiratory Division, Great Ormond Street Hospital for Children NHS Foundation Trust, London (United Kingdom); UCL Institute of Cardiovascular Science, Centre for Cardiovascular Imaging, London (United Kingdom); Sebire, Neil J. [UCL Institute of Child Health, London (United Kingdom); Department of Histopathology, Great Ormond Street Hospital for Children NHS Foundation Trust, London (United Kingdom)

    2015-04-01

    As postmortem imaging becomes more widely used following perinatal and paediatric deaths, the correct interpretation of images becomes imperative, particularly given the increased use of postmortem magnetic resonance imaging. Many pathological processes may have similar appearances in life and following death. A thorough knowledge of normal postmortem changes is therefore required within postmortem magnetic resonance imaging to ensure that these are not mistakenly interpreted as significant pathology. Similarly, some changes that are interpreted as pathological if they occur during life may be artefacts on postmortem magnetic resonance imaging that are of limited significance. This review serves to illustrate briefly those postmortem magnetic resonance imaging changes as part of the normal changes after death in fetuses and children, and highlight imaging findings that may confuse or mislead an observer to identifying pathology where none is present. (orig.)

  13. The diagnostic value of direct CT arthrography using MDCT in the evaluation of acetabular labral tear: with arthroscopic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Yong-Chan; Kim, Jae Yoon [Chung-Ang University College of Medicine, Department of Orthopaedic Surgery, Seoul (Korea, Republic of); Choi, Jung-Ah; Lee, Guen Young; Kang, Heung Sik [Seoul National University Bundang Hospital, Departments of Radiology, Seoul National University College of Medicine, 166 Gumi-ro, Bundang-gu, Seongnam (Korea, Republic of); Lee, Young-Kyun; Koo, Kyung-Hoi [Seoul National University Bundang Hospital, Orthopaedic Surgery, Seoul National University College of Medicine, Seongnam (Korea, Republic of)

    2013-05-15

    The purpose of this study was first, to determine the sensitivity, specificity, and accuracy of MDCT arthrography (CTA) for the diagnosis of acetabular labral tear and sulcus; second, to correlate tear types using the Lage classification system on CTA compared with the arthroscopic classification; and third, to correlate CTA localization with arthroscopic localization. Direct CTA was performed using 16- or 64-slice MDCT in 126 hips (124 patients) who had chronic groin pain and positive impingement test. Images were reviewed and evaluated by two experienced musculoskeletal radiologists preoperatively. CTA findings were compared with arthroscopic findings in 58 hips (56 patients) under consensus by two orthopedic surgeons. Forty-one of the 58 hips were diagnosed as labral tears on CT arthrography. Forty-three of the 58 hips were shown to have a labral tear on arthroscopy. Sensitivity, specificity, and accuracy for detecting labral tear and sulcus by CTA were 90.7%, 86.7%, and 89.7%, and 93.8%, 97.6% and 96.6% respectively for observer 1, and 90.7% and 80.0%, 87.9% and 87.5%, 95.2%, and 93.1 % respectively for observer 2. Thirty-five out of 41 hips (85%) that were diagnosed with labral tear on CTA correlated substantially with arthroscopic Lage classification (kappa coefficient = 0.65). CTA and arthroscopic findings showed similar distribution patterns of the tears with most lesions located in antero- and postero-superior areas (p = 0.013). Direct CT arthrography using MDCT may be a useful diagnostic technique in the detection of acetabular labral tear. (orig.)

  14. Nuclear magnetic resonance imaging

    International Nuclear Information System (INIS)

    Young, I.R.

    1984-01-01

    In a method of imaging a body in which nuclear magnetic resonance is excited in a region including part of the body, and the free induction decay signal is measured, a known quantity of a material of known nuclear magnetic resonance properties, for example a bag of water, is included in the region so as to enhance the measured free induction decay signal. This then reduces the generation of noise during subsequent processing of the signal. (author)

  15. Instability of the long head of the biceps tendon in patients with rotator cuff tear: evaluation on magnetic resonance arthrography of the shoulder with arthroscopic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Yusuhn; Lee, Joon Woo; Ahn, Joong Mo; Lee, Eugene; Kang, Heung Sik [Seoul National University Bundang Hospital, Department of Radiology, Seongnam-si, Gyeonggi-do (Korea, Republic of)

    2017-10-15

    To evaluate the diagnostic value of MR arthrography (MRA) in diagnosing instability of the LHBT in patients with rotator cuff tendon tear. The MR arthrograms of 101 patients were retrospectively reviewed and correlated with arthroscopic findings as the standard reference. Images were evaluated for (1) the integrity of the LHBT, (2) the position of the LHBT (subluxation/dislocation on axial images, inferior displacement on oblique sagittal image) and (3) the integrity of the biceps pulley (SGHL, supraspinatus and subscapularis tendon adjacent to the rotator interval). The integrity of the LHBT was correctly classified in 74.3% (75/101) and 66.3% (67/101) by readers 1 and 2, respectively. The diagnosis of LHBT instability could be made on axial images with a sensitivity of 82.6% and 73.9% and specificity of 69.9% and 87.7%, whereas the displacement sign on sagittal images had a sensitivity of 73.9% and 78.3% and a specificity of 64.4% and 61.6%, respectively. Assessing the integrity of the SGHL had a sensitivity of 60.9 and 93.3% and a specificity of 70.4 and 75.0%, respectively. By combining the different image findings, the accuracy in assessing LHBT instability was 80.9 and 90.5% with a sensitivity of 60.9 and 86.7% and specificity of 83.1 and 91.8%, respectively. Individual image findings may have a limited role in diagnosing LHBT instability in patients with rotator cuff tendon tear. The accuracy of MRA may be improved by assessing the integrity of the biceps pulley structures along with the position of the LHBT on both axial and sagittal images. (orig.)

  16. Imaging of hand injuries. Anatomic and radiodiagnostic considerations

    International Nuclear Information System (INIS)

    Schmitt, Rainer

    2011-01-01

    Imaging recommendations for assessing injuries of the forearm, wrist, metacarpus and the digits are given with respect to anatomic considerations. Furthermore, dedicated algorithms of advanced imaging are introduced with radiography as the primary diagnostic tool. High-resolution CT is used for detecting and staging the complex fractures of the radius and the wrist, whereas contrast-enhanced MRI serves for depicting the injured soft tissues. At the wrist, tears of the intrinsic ligaments and the TFCC are assessed with high accuracy when applying MR arthrography or CT arthrography. Dedicated radiologic tools as well as comprehensive reports are suggested in the management of the various hand injuries. (orig.)

  17. Shoulder arthrography: comparison of morbidity after use of various contrast media

    International Nuclear Information System (INIS)

    Hall, F.M.; Goldberg, R.P.; Wyshak, G.; Kilcoyne, R.F.

    1985-01-01

    This prospective study compares immediate and delayed patient discomfort in 177 patients following shoulder arthrography using intraarticular combinations of metrizamide, meglumine/sodium diatrizoate, meglumine diatrizoate, lidocaine, epinephrine, and air. Patients receiving conventional ionic monomeric positive contrast media had a 60% (90/150) incidence of moderate or severe delayed exacerbation of their baseline symptoms; only 14% (3/21) of patients receiving metrizamide, a nonionic contrast medium had similar levels of postprocedural discomfort. Morbidity was somewhat diminished with the use of double-contrast (45%, 34/75) rather than single-contrast (75%, 56/75) examinations, and with avoidance of sodium-containing contrast agents or epinephrine. Nonionic or monovalent polymeric contrast media, despite their present high cost, may be the agents of choice if single-contrast arthrography is performed in joints associated with a high incidence of postprocedural pain

  18. Temporomandibular joint arthrography: normal anatomy and technique of examination

    International Nuclear Information System (INIS)

    Duvoisin, B.; Schnyder, P.; Klaus, E.; Jacques, B.

    1990-01-01

    Temporomandibular joint (TMJ) dysfunction is common. This entity is most often consecutive to internal derangements of the TMJ, which are not recognizable on plain films and tomograms. TMJ arthrography has proved a valuable tool in diagnosing these abnormalities. The technique of examination and normal arthrographic anatomy are reviewed. (author) [pt

  19. Principles of magnetic resonance imaging

    International Nuclear Information System (INIS)

    Mlynarik, V.; Tkac, I.; Srbecky, M.

    1995-01-01

    The aim of this review is to describe and explain the basic principles of magnetic resonance imaging. The first part of the text is devoted to the phenomenon of magnetic resonance (the interaction of RF magnetic field with the set of magnetic moments in the homogeneous magnetic field) and to relaxation processes. Then, the creation of MR image is described (slice selection, phase and frequency encoding of spatial information). The basic and the most frequently used techniques are explained (spin echo, gradient echo). The way the repetition and echo times influence the image quality and contrast (T1 or T2 weighing) is described. The part with the technical description of the MR equipment is included in the review. The MR imagination examination are compared with X-ray computer tomography technique

  20. Bursae and abscess cavities communicating with the hip: diagnosis using arthrography and CT

    International Nuclear Information System (INIS)

    Steinbach, L.S.; Schneider, R.; Goldman, A.B.; Kazam, E.; Ranawat, C.S.; Ghelman, B.

    1985-01-01

    Bursae or abscess cavities communicating with the hip joint were demonstrated by hip arthrography or by computed tomography (CT) in 40 cases. The bursae or abscess cavities were associated with underlying abnormalities in the hip, including painful hip prostheses, infection, and inflammatory or degenerative arthritis. Symptoms may be produced directly as a result of infection or indirectly as a result of inflammation or pressure on adjacent structures. Hip arthrography can confirm a diagnosis of bursae and abscess cavities communicating with the hip joint in patients with hip pain or soft-tissue masses around the groin. Differentiation of enlarged bursae from other abnormalities is important to avoid unnecessary or incorrect surgery

  1. Magnetic resonance imaging of breast implants.

    Science.gov (United States)

    Shah, Mala; Tanna, Neil; Margolies, Laurie

    2014-12-01

    Silicone breast implants have significantly evolved since their introduction half a century ago, yet implant rupture remains a common and expected complication, especially in patients with earlier-generation implants. Magnetic resonance imaging is the primary modality for assessing the integrity of silicone implants and has excellent sensitivity and specificity, and the Food and Drug Administration currently recommends periodic magnetic resonance imaging screening for silent silicone breast implant rupture. Familiarity with the types of silicone implants and potential complications is essential for the radiologist. Signs of intracapsular rupture include the noose, droplet, subcapsular line, and linguine signs. Signs of extracapsular rupture include herniation of silicone with a capsular defect and extruded silicone material. Specific sequences including water and silicone suppression are essential for distinguishing rupture from other pathologies and artifacts. Magnetic resonance imaging provides valuable information about the integrity of silicone implants and associated complications.

  2. Intra-articular ganglion cysts of the knee: clinical and MR imaging features

    International Nuclear Information System (INIS)

    Kim, M.G.; Cho, W.H.; Kim, B.H.; Choi, J.A.; Lee, N.J.; Chung, K.B.; Choi, Y.S.; Cho, S.B.; Lim, H.C.

    2001-01-01

    The purpose of this study was to present clinical and MR imaging features of intra-articular ganglion cysts of the knee. Retrospective review of 1685 consecutive medical records and MR examinations of the knee performed at three imaging centers allowed identification of 20 patients (13 men and 7 women; mean age 35 years), in whom evidence of intra-articular ganglion cyst was seen. Of the 20 ganglion cysts, 5 were found in the infrapatellar fat pad, 10 arose from the posterior cruciate ligament, and 5 from the anterior cruciate ligament. Three of five patients with ganglion cyst in the infrapatellar fat pad had a palpable mass. In 7 of 15 patients with ganglion cyst in the intercondylar notch, exacerbation of pain occurred in a squatting position. On four MR arthrographies, ganglion cysts were an intra-articular round, lobulated, low signal intensity lesion. Five cases of fat-suppressed contrast-enhanced T1-weighted SE images demonstrated peripheral thin rim enhancement. The clinical presentation of intra-articular ganglion cyst is varied according to its intra-articular location. The MR appearance of intra-articular ganglion cyst is characteristic and usually associated with the cruciate ligament or the infrapatellar fat pad. Magnetic resonance arthrography has no definite advantage over conventional MR in the evaluation of the lesion. For intra-articular ganglion cyst in the infrapatellar fat pad, fat-suppressed contrast-enhanced MR imaging could be useful, because a thin, rim-enhancing feature of intra-articular ganglion cyst allows it to be distinguished from synovial hemangioma and synovial sarcoma. (orig.)

  3. Magnetic resonance imaging of radiation optic neuropathy

    International Nuclear Information System (INIS)

    Zimmerman, C.F.; Schatz, N.J.; Glaser, J.S.

    1990-01-01

    Three patients with delayed radiation optic neuropathy after radiation therapy for parasellar neoplasms underwent magnetic resonance imaging. The affected optic nerves and chiasms showed enlargement and focal gadopentetate dimeglumine enhancement. The magnetic resonance imaging technique effectively detected and defined anterior visual pathway changes of radionecrosis and excluded the clinical possibility of visual loss because of tumor recurrence

  4. Three-dimensional magnetic resonance imaging analysis of hip morphology in the assessment of femoral acetabular impingement

    International Nuclear Information System (INIS)

    Kavanagh, E.C.; Read, P.; Carty, F.; Zoga, A.C.; Parvizi, J.; Morrison, W.B.

    2011-01-01

    Aim: To determine a possible association between femoral-acetabular impingement (FAI) volume and the development of labral tear using a three-dimensional (3D) model reconstruction of the acetabulum and the femoral head. Materials and methods: Magnetic resonance arthrography images of the hip in 42 patients with pain and suspected labral tear were acquired using a 1.5 T MRI machine. Using 3D analysis software, outlines of the acetabular cup and femoral head were drawn and 3D reconstruction obtained. To control for differences in patient size, ratios of acetabulum : femoral head volume (AFV) and acetabulum : femoral head surface area (AFA) were used for analysis. The association between volume of acetabulum : femoral head and FAI was investigated using ANOVA analysis. Results: There were 19 men and 23 women with a mean age of 39 years (range 18-78 years). The average AFV was 0.64 (range 0.37-1.05, SD 0.16) and AFA was 0.73 (range 0.36-1.26, SD 0.23). Herniation pit was significantly associated with a small AFV. Conclusion: Femoral neck herniation pits are associated with a low AFV. Gross volume and surface area ratios do not appear to correlate with labral tears or cartilage loss. This technique will enable more advanced analysis of morphological variations associated with FAI.

  5. Content Based Retrieval System for Magnetic Resonance Images

    International Nuclear Information System (INIS)

    Trojachanets, Katarina

    2010-01-01

    The amount of medical images is continuously increasing as a consequence of the constant growth and development of techniques for digital image acquisition. Manual annotation and description of each image is impractical, expensive and time consuming approach. Moreover, it is an imprecise and insufficient way for describing all information stored in medical images. This induces the necessity for developing efficient image storage, annotation and retrieval systems. Content based image retrieval (CBIR) emerges as an efficient approach for digital image retrieval from large databases. It includes two phases. In the first phase, the visual content of the image is analyzed and the feature extraction process is performed. An appropriate descriptor, namely, feature vector is then associated with each image. These descriptors are used in the second phase, i.e. the retrieval process. With the aim to improve the efficiency and precision of the content based image retrieval systems, feature extraction and automatic image annotation techniques are subject of continuous researches and development. Including the classification techniques in the retrieval process enables automatic image annotation in an existing CBIR system. It contributes to more efficient and easier image organization in the system.Applying content based retrieval in the field of magnetic resonance is a big challenge. Magnetic resonance imaging is an image based diagnostic technique which is widely used in medical environment. According to this, the number of magnetic resonance images is enormously growing. Magnetic resonance images provide plentiful medical information, high resolution and specific nature. Thus, the capability of CBIR systems for image retrieval from large database is of great importance for efficient analysis of this kind of images. The aim of this thesis is to propose content based retrieval system architecture for magnetic resonance images. To provide the system efficiency, feature

  6. Diagnostic imaging of shoulder impingement

    International Nuclear Information System (INIS)

    Merl, T.; Weinhardt, H.; Oettl, G.; Lenz, M.; Riel, K.A.

    1996-01-01

    Magnetic resonance imaging is a method that has been advancing in the last few years to the modality of choice for diagnostic evaluation of the bone joints, as the method is capable of imaging not only the ossous but also the soft tissue components of the joint. MRI likewise has become an accepted method for diagnostic evaluation of syndromes of the shoulder, with high diagnostic accuracy in detecting rotator cuff lesions, or as an efficient MRI arthrography for evaluation of the instability or lesions of the labrocapsular complex. In the evaluation of early stages of shoulder impingement, the conventional MRI technique as a static technique yields indirect signs which in many cases do not provide the diagnostic certainty required in order to do justice to the functional nature of the syndrome. In these cases, functional MRI for imaging of the arm in abducted position and in rotational movement may offer a chance to early detect impingement and thus identify patients who will profit from treatment at an early stage [de

  7. Wrist Traction During MR Arthrography Improves Detection of Triangular Fibrocartilage Complex and Intrinsic Ligament Tears and Visibility of Articular Cartilage.

    Science.gov (United States)

    Lee, Ryan K L; Griffith, James F; Ng, Alex W H; Nung, Ryan C H; Yeung, David K W

    2016-01-01

    The purpose of this study was to assess the effects of traction during MR arthrography of the wrist on joint space widening, cartilage visibility, and detection of tears of the triangular fibrocartilage complex (TFCC) and intrinsic ligaments. A prospective study included 40 wrists in 39 patients (25 men, 14 women; mean age, 35 years). MR arthrography was performed with a 3-T MRI system with and without axial traction. Two radiologists independently measured wrist and carpal joint space widths and semiquantitatively graded articular cartilage visibility. Using conventional arthrography as the reference standard and working in consensus, they assessed for the presence of tears of the TFCC, lunotriquetral ligament (LTL), and scapholunate ligament (SLL). Visibility of a tear before traction was compared with visibility after traction. With traction, all joint spaces in the wrist and carpus were significantly widened (change, 0.15-1.01 mm; all p < 0.006). Subjective cartilage visibility of all joint spaces improved after traction (all p ≤ 0.048) except for that of the radioscaphoid space, which was well visualized even before traction. Conventional arthrography depicted 24 TFCC tears, seven LTL tears, and three SLL tears. The accuracy of tear detection improved after traction for the TFCC (98% after traction vs 83% before traction), the LTL (100% vs 88%), and the SLL (100% vs 95%). Tear visibility improved after traction for 54% of TFCC tears, 71% of LTL tears, and 66% of SLL tears. Wrist MR arthrography with axial traction significantly improved the visibility of articular cartilage and the detection and visibility of tears of the TFCC and intrinsic ligaments. The results favor more widespread use of traction during MR arthrography of the wrist.

  8. Paralabral cysts in the hip joint: findings at MR arthrography

    International Nuclear Information System (INIS)

    Magerkurth, Olaf; Jacobson, Jon A.; Girish, Gandikota; Kalume Brigido, Monica; Fessell, David; Bedi, Asheesh

    2012-01-01

    The purpose of this research was to retrospectively characterize paralabral cysts of the hip as seen at MR arthrography. After Institutional Review Board approval, 704 patients who had MR arthrography were identified over a 3-year period and 40 patients were identified as having a cyst or fluid collection at the hip by MR report. MR images from these 40 patients were retrospectively reviewed by three radiologists where 18 were found to have a paralabral cyst, which were characterized as follows: location, configuration, contrast filling, size of the cyst, extent, direction, and whether associated osseous changes were present. In addition, the acetabular labrum was assessed for tears and, if present, the location and pattern were characterized. Paralabral cysts were located anterosuperiorly in 56%, anteriorly in 22%, posterosuperiorly in 17%, and anteroinferiorly in 6% of cases. The vast majority (94%) were multilocular and filled with intra-articular contrast medium. The average dimensions were 8 x 7 x 11 mm. The paralabral cyst demonstrated extracapsular extension in 72% of cases, with 39% located between the ilium and gluteus minimus, and 22% between the ilium and iliopsoas. Remodeling of the ilium adjacent to the cyst was observed in 50% of these cases. A labral tear was at the base of the labrum adjacent to the cyst in 78% of cases, while the tear was isolated to the body of the labrum in 22%. Tears were most commonly anterosuperior (55%) or anterior (28%) in location. Our results show that paralabral cysts of the hip are most commonly located anterosuperiorly, are multilocular, fill with intra-articular contrast medium, have average dimensions up to 11 mm, and often extend extracapsularly between muscle and bone where they may remodel the adjacent ilium. (orig.)

  9. Usefulness of sono-guided needle puncture for MR arthrography of the shoulder

    International Nuclear Information System (INIS)

    Choi, Jae Woong; Hong, Suk Ju; Suh, San Il; Yong, Hwan Suk; Kim, Jung Hyuk; Park, Cheol Min; Suh, Won Hyuck; Kim, Myung Gyu

    2000-01-01

    To evaluate the usefulness of sono-guided needle puncture for MR arthrography of the shoulder to locate the path of access and to control the correct placement of the needle into the shoulder. Fifteen patients with suspicion of shoulder pathology were included in this study. Patients were laid in supine positions with the arm extended and slightly abducted, the palm of the hand facing upward. A sonographic unit with a high resolution transducer with 7.5 MHz linear array was used. Axial images in the anterior aspect of the shoulder were obtained to localize the coracoid process and the anteromedical portion of the humerus. Using an aseptic technique, a 21-guage needle was advanced into the shoulder joint under ultrasonographic guidance. When the needle made contract with the articular cartilage of the humeral head, the needle was tiled to position is point in the articular cavity. Solution of 0.1 ml gadopentetate dimeglumine in 25 ml of normal saline was prepared and 12-16 ml was injected into the joint cavity. The intra-articular position of the needle and the compete distension of the shoulder joint were again confirmed by sonography. The needle was accurately placed in 14 out of 15 patients without damage to neighboring structures. It took 10 to 15 minutes to complete the procedure in 14 patients. No side effects attributable to gadopentetate dimeglumine were found. Sono-guided needle puncture for the shoulder MR arthrography can be a substitutable method for fluoroscopic guidance, with easy access, advantages of lacking radiation hazard and eliminating the need for iodized contrast agents.

  10. Dental magnetic resonance imaging

    International Nuclear Information System (INIS)

    Hilgenfeld, Tim; Bendszus, Martin; Haehnel, Stefan

    2016-01-01

    Growing distribution and utilization of digital volume tomography (DVT) extend the spectrum of clinical dental imaging. Additional diagnostic value, however, comes along with an increasing amount of radiation. In contrast, magnetic resonance imaging is a radiation free imaging technique. Furthermore, it offers a high soft tissue contrast. Morphological and numerical dental anomalies, differentiation of periapical lesions and exclusion of complications of dental diseases are field of applications for dental MRI. In addition, detection of caries and periodontal lesions and injury of inferior alveolar nerve are promising application areas in the future.

  11. Cranial magnetic resonance imaging

    International Nuclear Information System (INIS)

    Elster, A.D.

    1988-01-01

    Cranial Magnetic Resonance Imaging is comprehensive, well structured, and well written. The material is current and well referenced. The illustrations are good and complement the text well. The overall quality of publication is above average. The greatest attribute of the book is its readability. The author demonstrates ample skill in making complex subjects, such as MR physics and imaging of cerebral hemorrhage, easy to understand. The book closes with a detailed atlas on the anatomic appearance of the brain on MR images in the axial, coronal, and sagittal planes

  12. Capsular contracture and possible implant rupture: is magnetic resonance imaging useful?

    Science.gov (United States)

    Paetau, Alyssa A; McLaughlin, Sarah A; McNeil, Rebecca B; Sternberg, Erez; TerKonda, Sarvam P; Waldorf, James C; Perdikis, Galen

    2010-03-01

    Currently, magnetic resonance imaging is considered the accepted standard to evaluate breast implant integrity. To evaluate its utility in diagnosing ruptured silicone implants in the setting of capsular contracture and to correlate the preoperative assessment of implant integrity with or without magnetic resonance imaging with operative findings, 319 capsulectomies (171 patients with capsular contractures) were retrospectively reviewed. Preoperative magnetic resonance imaging was done on 160 implants, whereas the remaining 159 were evaluated using only physical examination and/or mammography. Postoperative results were analyzed to determine the sensitivity, specificity, and accuracy of preoperative magnetic resonance imaging in comparison with clinical and/or mammography evaluation alone. Although occasionally valuable, overall, preoperative magnetic resonance imaging was no more accurate than clinical evaluation with or without mammography in predicting implant status: magnetic resonance imaging 124 of 160 (78 percent) and clinical 121 of 159 (76 percent; p = 0.77). In the setting of capsular contracture, physical examination with or without mammogram is as accurate as magnetic resonance imaging in determining implant integrity. Although magnetic resonance imaging is a sensitive diagnostic tool, in symptomatic patients with capsular contracture, it cannot be viewed as infallible.

  13. Diagnostic performance of MR arthrography with anterior trans-subscapularis versus posterior injection approach for subscapularis tendon tears at 3.0 T

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Joon-Yong; Jee, Won-Hee [Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Department of Radiology, Seoul (Korea, Republic of); Chun, Chang-Woo [Uijeongbu St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Department of Radiology, Uijeongbu-si, Gyeonggi-do (Korea, Republic of); Kim, Yang-Soo [Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Department of Orthopedic Surgery, Seoul (Korea, Republic of)

    2017-03-15

    To compare the diagnostic performance of shoulder magnetic resonance arthrography (MRA) with the anterior trans-subscapularis versus posterior injection approach to diagnose subscapularis tendon (SCT) tears. One hundred and sixty-seven arthroscopically confirmed patients (84 anterior and 83 posterior approaches) were included. Two readers retrospectively scored SCT tears. Proportions of correctly graded tears between MR arthrography and arthroscopy were calculated. Retrospective error analysis was performed. The sensitivity and specificity were 80 % (24/30) and 72 % (39/54) by reader 1, 73 % (22/30) and 76 % (41/54) by reader 2 in the anterior approach, and 86 % (30/35) and 79 % (38/48) by reader 1, 80 % (28/35) and 88 % (42/48) by reader 2 in the posterior approach, respectively. There were no significant differences in sensitivity and specificity between the two groups. Proportions of correctly graded tears of both readers were 48 % and 36 % in the anterior approach, and 70 % and 68 % in the posterior approach, respectively. The intratendinous collection of contrast material was not statistically significantly different between anterior (n = 8) and posterior (n = 3) approach group. For the MRA diagnosis of SCT tears, there was no significant difference between the anterior trans-subscapularis and the posterior approach. (orig.)

  14. Diagnostic performance of MR arthrography with anterior trans-subscapularis versus posterior injection approach for subscapularis tendon tears at 3.0 T

    International Nuclear Information System (INIS)

    Jung, Joon-Yong; Jee, Won-Hee; Chun, Chang-Woo; Kim, Yang-Soo

    2017-01-01

    To compare the diagnostic performance of shoulder magnetic resonance arthrography (MRA) with the anterior trans-subscapularis versus posterior injection approach to diagnose subscapularis tendon (SCT) tears. One hundred and sixty-seven arthroscopically confirmed patients (84 anterior and 83 posterior approaches) were included. Two readers retrospectively scored SCT tears. Proportions of correctly graded tears between MR arthrography and arthroscopy were calculated. Retrospective error analysis was performed. The sensitivity and specificity were 80 % (24/30) and 72 % (39/54) by reader 1, 73 % (22/30) and 76 % (41/54) by reader 2 in the anterior approach, and 86 % (30/35) and 79 % (38/48) by reader 1, 80 % (28/35) and 88 % (42/48) by reader 2 in the posterior approach, respectively. There were no significant differences in sensitivity and specificity between the two groups. Proportions of correctly graded tears of both readers were 48 % and 36 % in the anterior approach, and 70 % and 68 % in the posterior approach, respectively. The intratendinous collection of contrast material was not statistically significantly different between anterior (n = 8) and posterior (n = 3) approach group. For the MRA diagnosis of SCT tears, there was no significant difference between the anterior trans-subscapularis and the posterior approach. (orig.)

  15. In Vivo Imaging of Nitric Oxide by Magnetic Resonance Imaging Techniques

    Directory of Open Access Journals (Sweden)

    Rakesh Sharma

    2014-01-01

    Full Text Available Nitric oxide (NO biosensors are novel tools for real-time bioimaging of tissue oxygen changes and physiological monitoring of tissue vasculature. Nitric oxide behavior further enhances its role in mapping signal transduction at the molecular level. Spectrometric electron paramagnetic resonance (EPR and fluorometric imaging are well known techniques with the potential for in vivo bioimaging of NO. In tissues, NO is a specific target of nitrosyl compounds for chemical reaction, which provides a unique opportunity for application of newly identified NO biosensors. However, the accuracy and sensitivity of NO biosensors still need to be improved. Another potential magnetic resonance technique based on short term NO effects on proton relaxation enhancement is magnetic resonance imaging (MRI, and some NO biosensors may be used as potent imaging contrast agents for measurement of tumor size by MRI combined with fluorescent imaging. The present review provides supporting information regarding the possible use of nitrosyl compounds as NO biosensors in MRI and fluorescent bioimaging showing their measurement limitations and quantitative accuracy. These new approaches open a perspective regarding bioimaging of NO and the in vivo elucidation of NO effects by magnetic resonance techniques.

  16. Shoulder-Mounted Robot for MRI-guided arthrography: Accuracy and mounting study.

    Science.gov (United States)

    Monfaredi, R; Wilson, E; Sze, R; Sharma, K; Azizi, B; Iordachita, I; Cleary, K

    2015-08-01

    A new version of our compact and lightweight patient-mounted MRI-compatible 4 degree-of-freedom (DOF) robot for MRI-guided arthrography procedures is introduced. This robot could convert the traditional two-stage arthrography procedure (fluoroscopy-guided needle insertion followed by a diagnostic MRI scan) to a one-stage procedure, all in the MRI suite. The results of a recent accuracy study are reported. A new mounting technique is proposed and the mounting stability is investigated using optical and electromagnetic tracking on an anthropomorphic phantom. Five volunteer subjects including 2 radiologists were asked to conduct needle insertion in 4 different random positions and orientations within the robot's workspace and the displacement of the base of the robot was investigated during robot motion and needle insertion. Experimental results show that the proposed mounting method is stable and promising for clinical application.

  17. Magnetic resonance imaging in sudden deafness

    International Nuclear Information System (INIS)

    Ramos, Hugo Valter Lisboa; Barros, Flavia Alencar; Penido, Norma de Oliveira; Souza, Ana Claudia Valerio de; Yamaoka, Wellington Yugo; Yamashita, Helio

    2005-01-01

    The etiology of sudden deafness can remain undetermined despite extensive investigation. This study addresses the value of magnetic resonance imaging in the analysis of sudden deafness patients.Study Design: transversal cohort.Material And Method: In a prospective study, 49 patients attended at otolaryngology emergency room of Federal University of Sao Paulo - Escola Paulista de Medicina, from April 2001 to May 2003, were submitted to magnetic resonance imaging.Results: Magnetic Resonance abnormalities were seen in 23 (46.9%) patients and revealed two tumors suggestive of meningioma, three vestibular schwannomas, thirteen microangiopathic changes of the brain and five (21.7%) pathological conditions of the labyrinth.Conclusion: Sudden deafness should be approached as a symptom common to different diseases. The presence of cerebellopontine angle tumors in 10.2% of our cases, among other treatable causes, justifies the recommendation of gadolinium-enhanced magnetic resonance use, not only to study the auditory peripheral pathway, but to study the whole auditory pathway including the brain. (author)

  18. Imaging Algorithms for Evaluating Suspected Rotator Cuff Disease: Society of Radiologists in Ultrasound Consensus Conference Statement

    Science.gov (United States)

    Jacobson, Jon A.; Benson, Carol B.; Bancroft, Laura W.; Bedi, Asheesh; McShane, John M.; Miller, Theodore T.; Parker, Laurence; Smith, Jay; Steinbach, Lynne S.; Teefey, Sharlene A.; Thiele, Ralf G.; Tuite, Michael J.; Wise, James N.; Yamaguchi, Ken

    2013-01-01

    The Society of Radiologists in Ultrasound convened a panel of specialists from a variety of medical disciplines to reach a consensus about the recommended imaging evaluation of painful shoulders with clinically suspected rotator cuff disease. The panel met in Chicago, Ill, on October 18 and 19, 2011, and created this consensus statement regarding the roles of radiography, ultrasonography (US), computed tomography (CT), CT arthrography, magnetic resonance (MR) imaging, and MR arthrography. The consensus panel consisted of two co-moderators, a facilitator, a statistician and health care economist, and 10 physicians who have specialty expertise in shoulder pain evaluation and/or treatment. Of the 13 physicians on the panel, nine were radiologists who were chosen to represent a broad range of skill sets in diagnostic imaging, different practice types (private and academic), and different geographical regions of the United States. Five of the radiologists routinely performed musculoskeletal US as part of their practice and four did not. There was also one representative from each of the following clinical specialties: rheumatology, physical medicine and rehabilitation, orthopedic surgery, and nonoperative sports medicine. The goal of this conference was to construct several algorithms with which to guide the imaging evaluation of suspected rotator cuff disease in patients with a native rotator cuff, patients with a repaired rotator cuff, and patients who have undergone shoulder replacement. The panel hopes that these recommendations will lead to greater uniformity in rotator cuff imaging and more cost-effective care for patients suspected of having rotator cuff abnormality. © RSNA, 2013 PMID:23401583

  19. The effectiveness of diagnostic imaging methods for the assessment of soft tissue and articular disorders of the shoulder and elbow

    Energy Technology Data Exchange (ETDEWEB)

    Shahabpour, M. [Department of Radiology, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussels (Belgium)], E-mail: Maryam@shahabpour.uzbrussel; Kichouh, M.; Laridon, E. [Department of Radiology, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussels (Belgium); Gielen, J.L. [Department of Radiology, Universitair Ziekenhuis Antwerpen, Universiteit Antwerpen, Wilrijkstraat 10, 2650 Edegem (Belgium); De Mey, J. [Department of Radiology, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussels (Belgium)

    2008-02-15

    There are no clear guidelines for diagnostic imaging of articular and soft tissue pathologies of the shoulder and elbow. Several methods are used, including magnetic resonance imaging (MRI), magnetic resonance arthrography (MRA) and ultrasound (US). Their cost-effectiveness is still unclear. We performed a meta-analysis of the relevant literature and discussed the role of MR imaging of the shoulder and elbow compared with other diagnostic imaging modalities. For the shoulder impingement syndrome and rotator cuff tears, MRI and US have a comparable accuracy for detection of full-thickness rotator cuff tears. MRA and US might be more accurate for the detection of partial-thickness tears than MRI. Given the large difference in cost of MR and US, ultrasound may be the most cost-effective diagnostic method for identification of full-thickness tears in a specialist hospital setting (Evidence level 3). Both MRA and CT arthrography (CTA) are effective methods for the detection of labrum tears. More recently, multidetector CTA has offered the advantages of thinner slices than with MRA in a shorter examination time. Still, MRA has the advantage towards CTA to directly visualize the affected structures with a better evaluation of extent and location and to detect associated capsuloligamentous injuries. For the elbow pathologies, plain MRI or MRA have the advantage towards CTA to detect occult bone injuries. CTA is better for the assessment of the thin cartilage of the elbow. Both US and MRI are reliable methods to detect chronic epicondylitis; US is more available and far more cost-effective (Evidence level 2). MRA can differentiate complete from partial tears of the medial collateral ligament. US or MRI can detect partial and complete biceps tendon tears and/or bursitis. MRI can provide important diagnostic information in lesions of the ulnar, radial, or median nerve.

  20. Electron Paramagnetic Resonance Imaging

    Indian Academy of Sciences (India)

    Twentieth century bore witness to remarkable scientists whohave advanced our understanding of the brain. Among them,EPR (Electron Paramagnetic Resonance) imaging is particularlyuseful in monitoring hypoxic zones in tumors which arehighly resistant to radiation and chemotherapeutic treatment.This first part of the ...

  1. Can magnetic resonance imaging differentiate undifferentiated arthritis?

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Duer, Anne; Hørslev-Petersen, K

    2005-01-01

    A high sensitivity for the detection of inflammatory and destructive changes in inflammatory joint diseases makes magnetic resonance imaging potentially useful for assigning specific diagnoses, such as rheumatoid arthritis and psoriatic arthritis in arthritides, that remain undifferentiated after...... conventional clinical, biochemical and radiographic examinations. With recent data as the starting point, the present paper describes the current knowledge on magnetic resonance imaging in the differential diagnosis of undifferentiated arthritis....

  2. [Surface coils for magnetic-resonance images].

    Science.gov (United States)

    Rodríguez-González, Alfredo Odón; Amador-Baheza, Ricardo; Rojas-Jasso, Rafael; Barrios-Alvarez, Fernando Alejandro

    2005-01-01

    Since the introduction of magnetic resonance imaging in Mexico, the development of this important medical imaging technology has been almost non-existing in our country. The very first surface coil prototypes for clinical applications in magnetic resonance imaging has been developed at the Center of Research in Medical Imaging and Instrumentation of the Universidad Autónoma Metropolitana Iztapalapa (Metropolitan Autonomous University, Campus Iztapalapa). Two surface coil prototypes were built: a) a circular-shaped coil and b) a square-shaped coil for multiple regions of the body, such as heart, brain, knee, hands, and ankles. These coils were tested on the 1.5T imager of the ABC Hospital-Tacubaya, located in Mexico City. Brain images of healthy volunteers were obtained in different orientations: sagittal, coronal, and axial. Since images showed a good-enough clinical quality for diagnosis, it is fair to say that these coil prototypes can be used in the clinical environment, and with small modifications, they can be made compatible with almost any commercial scanner. This type of development can offer new alternatives for further collaboration between the research centers and the radiology community, in the search of new applications and developments of this imaging technique.

  3. Comparison of radiographic and radionuclide hip arthrography in determination of femoral component loosening of hip arthroplasties

    International Nuclear Information System (INIS)

    Capello, W.N.; Uri, B.G.; Wellman, H.N.; Robb, J.A.; Stiver, P.L.

    1985-01-01

    Radiographic examination of a patient experiencing pain following total hip arthroplasty is an important step in the systematic approach to evaluating component loosening, even though the information yielded is often equivocal and nondiagnostic in assessing component loosening. The radiographic criteria for loosening are especially difficult to assess following revision surgery, for radiolucent lines frequently exist at the bone-cement interface immediately following implantation. The advent of noncemented hip prostheses poses another problem: the routinely noted disruption of bone-cement of prosthesis-cement interfaces is not present with uncemented prostheses. As the criteria for loosening of the noncemented prostheses are still evolving, plain radiographic examination is frequently nondiagnostic. Femoral component loosening is difficult to detect with standard contrast arthrography because the bone, metal, surrounding radiopaque cement and contrast agents have similar or identical radiographic appearances. In contrast arthrography, if the prosthesis is loose the injected agent opacifies the radiolucent zone encircling the prosthesis or cement mangle. Because of the similarity in the appearances of these agents and the surrounding structures on x-ray films, interpretation is difficult. The inclusion of subtraction techniques in routine contrast arthrography has improved its accuracy; however, these techniques require special equipment and demand precise patient positioning. The purpose of this study is to introduce a new form of hip arthrography using a radionuclide agent in place of the contrast agent. A comparison of the results using these two techniques is presented

  4. Incidence of greater trochanteric pain syndrome in patients suspected for femoroacetabular impingement evaluated using magnetic resonance arthrography of the hip.

    Science.gov (United States)

    Pozzi, Grazia; Lanza, Ezio; Parra, Cleber Garcia; Merli, Ilaria; Sconfienza, Luca Maria; Zerbi, Alberto

    2017-03-01

    We evaluated the incidence of greater trochanter pain syndrome (GTPS) in patients who underwent magnetic resonance arthrography (MRA) of the hip for a suspected femoroacetabular impingement (FAI) syndrome. Hip MRA performed at our institution (3/2012-1/2014) were reviewed. The absence/presence of FAI (cam, pincer, and mixed) was noted. GTPS diagnosis was based on gluteus medius/minimus tendinopathy/tears, trochanteric bursitis, fascia lata thickening, and trochanter bone oedema/erosion. Subgroup analysis for age (under/over 40 years) and FAI type (cam, pincer, and mixed) was also performed. N = 189 patients were included (n = 125 males; age 39 ± 12 years). FAI was diagnosed in n = 133 (70, 4%): cam type, n = 85 (63, 9%); pincer type, n = 22 (16, 6%); and mixed type, n = 26 (19, 5%). N = 72 patients (38.1%) had tendinopathy, n = 14 (7.4%) had trochanter erosion, n = 31 (16.4%) had bursitis, n = 4 had bone oedema (2.1%), and n = 3 (1.6%) had fascia lata thickening, resulting in GTPS diagnosis in n = 74 patients (39.2%). The association of normal hip morphology/GTPS was significantly higher (P = 0.023) than that of FAI/GTPS. Under 40 years, GTPS incidence was higher in patients with normal hip and pincer-type FAI (P = 0.028). Over 40 years, no difference between patients with/without FAI (P = 0.119) was seen. GTPS was more frequently observed in patients with normal hip morphology than in patients with FAI, particularly in patients under 40.

  5. 16-slice MDCT arthrography of the shoulder: accuracy for detection of glenoid labral and rotator cuff tears

    International Nuclear Information System (INIS)

    Kim, Gang Deuk; Kim, Huoung Jun; Kim, Hye Won; Oh, Jung Taek; Juhng, Seon Kwan; Lee, Sung Ah

    2007-01-01

    We wanted to determine the diagnostic accuracy of 16-slice MDCT arthrography (CTA) for glenoid labral and rotator cuff tears of the shoulder. We enrolled forty-five patients who underwent arthroscopy after CTA for pain or instability of the shoulder joint. The CTA images were analyzed for the existence, sites and types of glenoid labral tears and the presence and severity of rotator cuff tears. We determined the sensitivity, specificity and accuracy of CTA for detecting glenoid labral and rotator cuff tears on the basis of the arthroscopy findings. At arthroscopy, there were 33 SLAP lesions (9 type I, 23 type II and 1 type III), 6 Bankart lesions and 31 rotator cuff lesions (21 supraspinatus, 9 infraspinatus and 1 subscapularis). On CTA, the sensitivity, specificity and accuracy for detecting 24 SLAP lesions, excluding the type I lesions, were 83%, 100% and 91%, the total rotator cuff tears were 90%, 100% and 98%, the full thickness supraspinatus tendon tears were 100%, 94% and 96%, and the partial thickness supraspinatus tendon tears were 29%, 100% and 89%, respectively. 16-slice MDCT arthrography has high accuracy for the diagnosis of abnormality of the glenoid labrum or rotator cuff tears and it can be a useful alternative to MRI or US

  6. 16-slice MDCT arthrography of the shoulder: accuracy for detection of glenoid labral and rotator cuff tears

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Gang Deuk; Kim, Huoung Jun; Kim, Hye Won; Oh, Jung Taek; Juhng, Seon Kwan [Wonkwang University Hospital, Iksan (Korea, Republic of); Lee, Sung Ah [Seoul Medical Center, Seoul (Korea, Republic of)

    2007-04-15

    We wanted to determine the diagnostic accuracy of 16-slice MDCT arthrography (CTA) for glenoid labral and rotator cuff tears of the shoulder. We enrolled forty-five patients who underwent arthroscopy after CTA for pain or instability of the shoulder joint. The CTA images were analyzed for the existence, sites and types of glenoid labral tears and the presence and severity of rotator cuff tears. We determined the sensitivity, specificity and accuracy of CTA for detecting glenoid labral and rotator cuff tears on the basis of the arthroscopy findings. At arthroscopy, there were 33 SLAP lesions (9 type I, 23 type II and 1 type III), 6 Bankart lesions and 31 rotator cuff lesions (21 supraspinatus, 9 infraspinatus and 1 subscapularis). On CTA, the sensitivity, specificity and accuracy for detecting 24 SLAP lesions, excluding the type I lesions, were 83%, 100% and 91%, the total rotator cuff tears were 90%, 100% and 98%, the full thickness supraspinatus tendon tears were 100%, 94% and 96%, and the partial thickness supraspinatus tendon tears were 29%, 100% and 89%, respectively. 16-slice MDCT arthrography has high accuracy for the diagnosis of abnormality of the glenoid labrum or rotator cuff tears and it can be a useful alternative to MRI or US.

  7. Dislocation of the temporomandibular joint meniscus: contrast arthrography vs. computed tomography

    International Nuclear Information System (INIS)

    Thompson, J.R.; Christiansen, E.; Sauser, D.; Hasso, A.N.; Hinshaw, D.B. Jr.

    1985-01-01

    A prospective study to determine the accuracy of computed tomography (CT) for the diagnosis of dislocation of the temporomandibular joint (TMJ) meniscus was made by performing both CT and contrast arthrography on 18 joints suspected of meniscus dislocation. Arthography rather than surgery was chosen as the quality standard for comparing CT findings, as not all patients undergoing the studies underwent surgery. The results of each test were reported independently by the radiologist who obtained either all of the arthograms or all of the CT scans. For dislocation of the meniscus, there were excellent agreement between the two methods. CT seems to be nearly as accurate as arthrography for showing meniscus dislocation, is performed with lower x-ray exposure, and is noninvasive. Arthrograpy discloses more detailed information about the joint meniscus, such as perforation and maceration, and should continue to be used when this kind of information is clinically important

  8. Magnetic resonance imaging: hazard, risk and safety

    International Nuclear Information System (INIS)

    Narayan, Pradeep; Suri, S.; Singh, P.

    2001-01-01

    The hazard and risk associated with magnetic resonance imaging is a matter of concern. In 1982, the Food and Drug Administration (FDA), USA issued guidelines to Hospital's Investigational Review Board (IRBs) in 'Guidelines for Evaluating Electromagnetic Exposure Risks for Trials of Clinical Nuclear Magnetic Resonance (NMR)'. In 1997, the Berufsgenossenschaft (BG), professional association for precision engineering and electronics of Germany, in their preliminary proposal for safety limits extended their concerns on static magnetic field. Owing to both time varying and static magnetic fields applied in Magnetic Resonance Imaging (MRI) this became of immediate concern to user community to assess the potential hazard and risk associated with the NMR system

  9. Magnetic resonance imaging of central nervous system haemorrhage

    International Nuclear Information System (INIS)

    Silberstein, M.; Hennessy, O.

    1993-01-01

    The variable magnetic resonance imaging appearances of central nervous system haemorrhage, both intra- and extra-axial, are described. These will vary with the type of image contrast (T1 or T2 weighting), the nature of the imaging sequence (spin-echo or gradient-echo) and the time from onset of haemorrhage. Magnetic resonance imaging is a useful technique for imaging haemorrhage in the central nervous system as it yields temporal information about haematoma development, and it is the only non-invasive means of imaging intraspinal haemorrhage. However, in the imaging of haematomas within 24 h of onset and in subarachnoid haemorrhage computed tomography is the investigation of choice. 13 refs., 6 figs

  10. Magnetic resonance imaging of chemistry.

    Science.gov (United States)

    Britton, Melanie M

    2010-11-01

    Magnetic resonance imaging (MRI) has long been recognized as one of the most important tools in medical diagnosis and research. However, MRI is also well placed to image chemical reactions and processes, determine the concentration of chemical species, and look at how chemistry couples with environmental factors, such as flow and heterogeneous media. This tutorial review will explain how magnetic resonance imaging works, reviewing its application in chemistry and its ability to directly visualise chemical processes. It will give information on what resolution and contrast are possible, and what chemical and physical parameters can be measured. It will provide examples of the use of MRI to study chemical systems, its application in chemical engineering and the identification of contrast agents for non-clinical applications. A number of studies are presented including investigation of chemical conversion and selectivity in fixed-bed reactors, temperature probes for catalyst pellets, ion mobility during tablet dissolution, solvent dynamics and ion transport in Nafion polymers and the formation of chemical waves and patterns.

  11. Quantitative magnetic resonance micro-imaging methods for pharmaceutical research.

    Science.gov (United States)

    Mantle, M D

    2011-09-30

    The use of magnetic resonance imaging (MRI) as a tool in pharmaceutical research is now well established and the current literature covers a multitude of different pharmaceutically relevant research areas. This review focuses on the use of quantitative magnetic resonance micro-imaging techniques and how they have been exploited to extract information that is of direct relevance to the pharmaceutical industry. The article is divided into two main areas. The first half outlines the theoretical aspects of magnetic resonance and deals with basic magnetic resonance theory, the effects of nuclear spin-lattice (T(1)), spin-spin (T(2)) relaxation and molecular diffusion upon image quantitation, and discusses the applications of rapid magnetic resonance imaging techniques. In addition to the theory, the review aims to provide some practical guidelines for the pharmaceutical researcher with an interest in MRI as to which MRI pulse sequences/protocols should be used and when. The second half of the article reviews the recent advances and developments that have appeared in the literature concerning the use of quantitative micro-imaging methods to pharmaceutically relevant research. Copyright © 2010 Elsevier B.V. All rights reserved.

  12. Is sonography performed by the rheumatologist as useful as arthrography executed by the radiologist for the assessment of full thickness rotator cuff tears?

    NARCIS (Netherlands)

    Swen, W. A.; Jacobs, J. W.; Neve, W. C.; Bal, D.; Bijlsma, J. W.

    1998-01-01

    Sonography and arthrography are techniques used to detect rotator cuff tears (RCT). The diagnostic value of sonography executed by a rheumatologist versus that of arthrography performed by a radiologist for assessment of RCT was investigated among patients with unilateral chronic shoulder complaints

  13. Imaging Atherosclerosis with Hybrid Positron Emission Tomography/Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Ripa, Rasmus Sejersten; Kjær, Andreas

    2015-01-01

    Noninvasive imaging of atherosclerosis could potentially move patient management towards individualized triage, treatment, and followup. The newly introduced combined positron emission tomography (PET) and magnetic resonance imaging (MRI) system could emerge as a key player in this context. Both...

  14. Magnetic resonance imaging of generalised musculo-skeletal diseases

    International Nuclear Information System (INIS)

    Kaiser, W.A.; Schalke, B.C.G.

    1989-01-01

    The results presented are drawn from 320 examinations by NMR imaging of patients with various systemic muscle diseases (dystrophies, myositides, metabolic disorders), and are interpreted so as to explain the relevant characteristic distribution patterns of the degenerative processes in the femoral musculature as shown by the NMR images. Four basic patterns are presented according to the criteria homogeneous-heterogeneous and symmetric-asymmetric, and the diseases identified by the differential diagnostic evaluation are discussed. The optimum measuring conditions for magnetic resonance imaging of the musculature are given, and the specific magnetic resonance criteria of myositides, neurogenic myopathies, myofonous dystrophies, c.n. polio, morbus Pompe, familial hypokalemic paralysis, centronuclear mypathy, morbus Duchenne are explained. The significance of NMR imaging with regard to biopsy or therapy planning is discussed, and magnetic resonance examination is recommended to be applied prior to biopsy. (orig.) [de

  15. MR arthrography of the shoulder: Do we need local anesthesia?

    International Nuclear Information System (INIS)

    Spick, Claudio; Szolar, Dieter H.M.; Reittner, Pia; Preidler, Klaus W.; Tillich, Manfred

    2014-01-01

    Purpose: To assess pain intensity with and without subcutaneous local anesthesia prior to intraarticular administration of contrast medium for magnetic resonance arthrography (MRa) of the shoulder. Materials and methods: This single-center study was conducted after an IRB waiver of authorization, between January 2010 and December 2012. All patients provided written, informed consent for the procedure. Our prospectively populated institutional database was searched, based on our inclusion criteria. There were 249 outpatients (178 men and 71 women; mean age, 44.4 years ± 14.6; range, 15–79) who underwent MRa and were enrolled in this study. Patients were excluded if they had received surgery of the shoulder before MRa, had undergone repeated MRa of the same shoulder, and/or had undergone MRa of both shoulders on the same day. Patients were randomly assigned into one of three groups. Patients in group A (n = 61) received skin infiltration with local anesthesia. Patients in control group B (n = 92) and group C (n = 96) did not receive local anesthesia. Pain levels were immediately assessed after the injection for MRa using a horizontal visual analog scale (VAS) that ranged from 0 to 10. To compare the pain scores of the three groups for male and female patients, a two-way analysis of variance was used. A p-value equal to or less than 0.05 was considered to indicate a significant result. Results: Patients who received local anesthesia (group A) showed a mean pain level on the VAS of 2.6 ± 2.3. In patients who did not receive local anesthetics (groups B and C), a mean pain level on the VAS of 2.6 ± 2.2 and 2.7 ± 2.4 were detected, respectively. Between the three groups, no statistically significant difference in pain intensity was detected (p = .960). There were significant differences in subjective pain perception between men and women (p = .009). Moreover, the sex difference in all three groups was equal (p = .934). Conclusion: Local anesthesia is not required to

  16. MR arthrography of the shoulder: Do we need local anesthesia?

    Energy Technology Data Exchange (ETDEWEB)

    Spick, Claudio, E-mail: claudio.spick@meduniwien.ac.at [Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna (AKH), Waehringer-Guertel 18-20, 1090 Vienna (Austria); Szolar, Dieter H.M.; Reittner, Pia; Preidler, Klaus W.; Tillich, Manfred [Diagnostikum Graz-Südwest, Weblinger Guertel 25, 8054 Graz (Austria)

    2014-06-15

    Purpose: To assess pain intensity with and without subcutaneous local anesthesia prior to intraarticular administration of contrast medium for magnetic resonance arthrography (MRa) of the shoulder. Materials and methods: This single-center study was conducted after an IRB waiver of authorization, between January 2010 and December 2012. All patients provided written, informed consent for the procedure. Our prospectively populated institutional database was searched, based on our inclusion criteria. There were 249 outpatients (178 men and 71 women; mean age, 44.4 years ± 14.6; range, 15–79) who underwent MRa and were enrolled in this study. Patients were excluded if they had received surgery of the shoulder before MRa, had undergone repeated MRa of the same shoulder, and/or had undergone MRa of both shoulders on the same day. Patients were randomly assigned into one of three groups. Patients in group A (n = 61) received skin infiltration with local anesthesia. Patients in control group B (n = 92) and group C (n = 96) did not receive local anesthesia. Pain levels were immediately assessed after the injection for MRa using a horizontal visual analog scale (VAS) that ranged from 0 to 10. To compare the pain scores of the three groups for male and female patients, a two-way analysis of variance was used. A p-value equal to or less than 0.05 was considered to indicate a significant result. Results: Patients who received local anesthesia (group A) showed a mean pain level on the VAS of 2.6 ± 2.3. In patients who did not receive local anesthetics (groups B and C), a mean pain level on the VAS of 2.6 ± 2.2 and 2.7 ± 2.4 were detected, respectively. Between the three groups, no statistically significant difference in pain intensity was detected (p = .960). There were significant differences in subjective pain perception between men and women (p = .009). Moreover, the sex difference in all three groups was equal (p = .934). Conclusion: Local anesthesia is not required to

  17. Diffusion and Perfusion Magnetic Resonance Imaging:Fundamentals and Advances

    OpenAIRE

    Assili, Sanam

    2016-01-01

    Over the past few decades, magnetic resonance imaging has been utilized as a powerful imaging modality to evaluate the structure and function of various organs in the human body,such as the brain. Additionally, diffusion and perfusion MR imaging have been increasingly used in neurovascular clinical applications. In diffusion-weighted magnetic resonance imaging, the mobility of water molecules is explored in order to obtain information about the microscopic behavior of the tissues. In contrast...

  18. Magnetic resonance imaging: effects of magnetic field strength

    International Nuclear Information System (INIS)

    Crooks, L.E.; Arakawa, M.; Hoenninger, J.; McCarten, B.; Watts, J.; Kaufman, L.

    1984-01-01

    Magnetic resonance images of the head, abdomen, and pelvis of normal adult men were obtained using varying magnetic field strength, and measurements of T1 and T2 relaxations and of signal-to-noise (SN) ratios were determined. For any one spin echo sequence, gray/white matter contrast decreases and muscle/fat contrast increases with field. SN levels rise rapidly up to 3.0 kgauss and then change more slowly, actually dropping for muscle. The optimum field for magnetic resonance imaging depends on tissue type, body part, and imaging sequence, so that it does not have a unique value. Magnetic resonance systems that operate in the 3.0-5.0 kgauss range achieve most or all of the gains that can be achieved by higher magnetic fields

  19. Radiologic findings of double contrast knee arthrography

    International Nuclear Information System (INIS)

    Choi, Hye Ran; Ahn, Byeong Yeob; Kim, Mi Young; Lee, So Hyun; Suh, Chang Hae; Chung, Won Kyun

    1990-01-01

    The double contrast arthrography of the knee is a highly accurate diagnostic modality in wide rage of the clinical disorders of the knee. It allows radiological assessment of the menisci, the articular cartilages, the synovium and the ligaments. The double contrast knee arthrography was performed in 356 cases at Inha hospital for about 3 years from June 1986 to June 1989. Among them, 115 cases were abnormal, and were analyzed clinically and radiologically with the back ground of the operative finding. The results were as follows ; 1. Of the 115 cases, male were 77 and female 38. Male exceeds female in the ratio of 2 : 1. 2. The age group of 20 - 39 years was commonly involved (60%). 3. The right knee was more commonly involved than the left and the medial meniscus tear was more common (61%). The posterior horn of the meniscus was more frequently torn than the other parts of the meniscus (42%). 4. The incidence of the bucket-handle tear was the most frequent (33%). 5. The cases of the popliteal cyst were 16 (13.9%), and the combined meniscus tears were in 4 cases (25%). 6. The numbers of the discoid meniscus were 9 (7.8%), and all were present in the lateral meniscus, and combined tears were in 4 cases (44.4%). 7. The diagnostic accuracy of the double contrast knee arthrogram was 82.7% compared with operative finding. The false positive examination were 17.3%

  20. Contrast agents in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Karadjian, V.

    1987-01-01

    The origine of nuclear magnetic resonance signal is reminded and different ways for contrast enhancement in magnetic resonance imaging are presented, especially, modifications of tissus relaxation times. Investigations have focused on development of agents incorporating either paramagnetic ions or stable free radicals. Pharmacological and toxicological aspects are developed. The diagnostic potential of these substances is illustrated by the example of gadolinium complexes [fr

  1. Magnetic resonance imaging of the abdomen and pelvis

    International Nuclear Information System (INIS)

    Anon.

    1989-01-01

    Magnetic resonance imaging (MRI) of the abdomen presents greater inherent difficulties than other anatomic regions. However, new techniques now allow imaging comparable in quality to computed tomography (CT). Magnetic resonance imaging offers the advantages of greater tissue contrast, multiplanar imaging, and lack of ionizing radiation or risk of toxic reactions from iodinated contrast media. Its use remains limited by high cost, limited availability, lack of a bowel contrast agent, and long imaging time, which some patients cannot tolerate. In many areas of abdominal imaging, MRI is now comparable to CT, but because of the greater availability and lesser cost, CT remains the procedure of choice. Magnetic resonance imaging is more accurate for staging neoplasms of the liver, adrenal glands, kidneys, bladder, prostate, uterus, and cervix and may aid in diagnosis of hepatic, adrenal, and uterine masses. In selected patients, especially those in whom CT is inconclusive or those who cannot tolerate iodinated contrast material, MRI can provide valuable information. Development of faster scanning techniques and MRI contrast agents and wider availability will probably increase the usefulness of abdominal MRI. At this time, MRI complements other abdominal imaging procedures. In a small number of patients, however, it can provide unique information in a virtually risk-free manner

  2. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... MRI) exam. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Catheter Angiography Magnetic Resonance, ...

  3. Role of arthrography in the management of dysplasia epiphysealis hemimelica

    Energy Technology Data Exchange (ETDEWEB)

    Ho, A.M.W.; Blane, C.E.; Kling, T.F. Jr.

    1986-03-01

    Dysplasia epiphysealis hemimelica can be diagnosed on plain radiographs of the affected areas. However, double contrast arthrography in three new cases provided additional information. The cartilaginous portions of the lesion at the articular surface of the bone were precisely demonstrated, aiding the orthopedic surgeon in deciding which patients should have surgery and planning the extent of operation necessary.

  4. Bilateral three-compartment wrist arthrography in patients with unilateral wrist pain: findings and implications for management

    International Nuclear Information System (INIS)

    Romaniuk, C.S.; Butt, W.P.; Coral, A.

    1995-01-01

    Bilateral three-compartment wrist arthrography was performed in 30 patients with unilateral post-traumatic wrist pain to assess the incidence of bilateral findings. The mean age of patients was 30 (range 18-55) years. Thirty-three percent of patients were normal bilaterally, 30% had unilateral communication in the symptomatic wrist, 30% had communications in both the symptomatic and asymptomatic wrists and 7% had communication in the asymptomatic wrist only. Unilateral three-compartment wrist arthrography is not recommended in the assessment of unilateral post-traumatic wrist pain; no advantage of three-compartment injection over radiocarpal injection alone was shown. (orig.)

  5. Radiography, radionuclide imaging, and asthrography in the evaluation of total hip and knee replacement

    International Nuclear Information System (INIS)

    Gelman, M.I.; Coleman, R.E.; Stevens, P.M.; Davey, B.W.

    1978-01-01

    Twenty patients with 21 total joint replacements including 17 hips and 4 knees were studied by plain film radiography, radionuclide imaging, and subtraction arthrography to evaluate these procedures for assessing prosthetic complications. Surgery was performed in 14 patients and confirmed loosening of 8 femoral and 7 acetabular hip prosthesis components and 1 femoral and 4 tibial knee prosthesis components. Plain films suggested loosening of only 9 hip components and no knee components. In contrast, radionuclide imaging and subtraction arthrography were considerably more effective in demonstrating loosening as well as other causes of the painful total joint prosthesis

  6. Magnetic resonance imaging in the cranio-cervical region

    International Nuclear Information System (INIS)

    Koschorek, F.; Jensen, H.P.; Terwey, B.

    1987-01-01

    Since the introduction of nuclear magnetic resonance imaging (NMR) in the neurosurgical and neurological diagnostic this new imaging modality has shown to be of high diagnostic value - especially in disease process of the cranio-vertebral junction. Other imaging moralities such as x-ray CT and myelography are of inferior quality as the images are degraded by bone artifacts and superposition of other structures. NMR can reveal many aspects of the cranio-vertebral region in a single examination without artifacts from surrounding structures. A further improvement of NMR is the introduction of para-magnetic agents, such as gadolinium-DTPA, as it increases the specifity by dynamic magnetic resonance imaging. The authors present a review of their clinical experience

  7. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... are the limitations of MRI of the Head? What is MRI of the Head? Magnetic resonance imaging ( ... brain) in routine clinical practice. top of page What are some common uses of the procedure? MR ...

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... is not harmful, but it may cause some medical devices to malfunction. Most orthopedic implants pose no ... Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. ...

  9. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance ...

  10. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... magnetic resonance imaging (MRI) uses a powerful magnetic field, radio waves and a computer to produce detailed ... problems, medications, recent surgeries and allergies. The magnetic field is not harmful, but it may cause some ...

  11. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... be necessary. Your doctor will explain the exact reason why another exam is requested. Sometimes a follow- ... necessary in trauma situations. Although there is no reason to believe that magnetic resonance imaging harms the ...

  12. Task-oriented lossy compression of magnetic resonance images

    Science.gov (United States)

    Anderson, Mark C.; Atkins, M. Stella; Vaisey, Jacques

    1996-04-01

    A new task-oriented image quality metric is used to quantify the effects of distortion introduced into magnetic resonance images by lossy compression. This metric measures the similarity between a radiologist's manual segmentation of pathological features in the original images and the automated segmentations performed on the original and compressed images. The images are compressed using a general wavelet-based lossy image compression technique, embedded zerotree coding, and segmented using a three-dimensional stochastic model-based tissue segmentation algorithm. The performance of the compression system is then enhanced by compressing different regions of the image volume at different bit rates, guided by prior knowledge about the location of important anatomical regions in the image. Application of the new system to magnetic resonance images is shown to produce compression results superior to the conventional methods, both subjectively and with respect to the segmentation similarity metric.

  13. In Vivo Application of Proton-Electron Double-Resonance Imaging

    Science.gov (United States)

    Kishimoto, Shun; Krishna, Murali C.; Khramtsov, Valery V.; Utsumi, Hideo

    2018-01-01

    Abstract Significance: Proton-electron double-resonance imaging (PEDRI) employs electron paramagnetic resonance irradiation with low-field magnetic resonance imaging so that the electron spin polarization is transferred to nearby protons, resulting in higher signals. PEDRI provides information about free radical distribution and, indirectly, about the local microenvironment such as partial pressure of oxygen (pO2), tissue permeability, redox status, and acid-base balance. Recent Advances: Local acid-base balance can be imaged by exploiting the different resonance frequency of radical probes between R and RH+ forms. Redox status can also be imaged by using the loss of radical-related signal after reduction. These methods require optimized radical probes and pulse sequences. Critical Issues: High-power radio frequency irradiation is needed for optimum signal enhancement, which may be harmful to living tissue by unwanted heat deposition. Free radical probes differ depending on the purpose of PEDRI. Some probes are less effective for enhancing signal than others, which can reduce image quality. It is so far not possible to image endogenous radicals by PEDRI because low concentrations and broad line widths of the radicals lead to negligible signal enhancement. Future Directions: PEDRI has similarities with electron paramagnetic resonance imaging (EPRI) because both techniques observe the EPR signal, directly in the case of EPRI and indirectly with PEDRI. PEDRI provides information that is vital to research on homeostasis, development of diseases, or treatment responses in vivo. It is expected that the development of new EPR techniques will give insights into novel PEDRI applications and vice versa. Antioxid. Redox Signal. 28, 1345–1364. PMID:28990406

  14. Waveguide volume probe for magnetic resonance imaging and spectroscopy

    DEFF Research Database (Denmark)

    2015-01-01

    The present disclosure relates to a probe for use within the field of nuclear magnetic resonance, such as magnetic resonance imaging (MRI), and magnetic resonance spectroscopy (MRS)). One embodiment relates to an RF probe for magnetic resonance imaging and/or spectroscopy comprising a conductive...... non-magnetic hollow waveguide having an internal volume and at least one open end, one or more capacitors and at least a first conductive non-magnetic wire, wherein said first conductive wire connects at least one of said one or more capacitors to opposite walls of one open end of the waveguide...

  15. Adhesive capsulitis of the shoulder: MR arthrography

    International Nuclear Information System (INIS)

    Kim, Hyun Jeong; Han, Tae Il; Lee, Kwang Won; Choi, Youn Seon; Kim, Dae Hong; Han, Hyun Young; Song, Mun Kab; Kwon, Soon Tae

    2001-01-01

    Adhesive capsulitis is a clinical syndrome involving pain and decreased joint motion caused by thickening and contraction of the joint capsule. The purpose of this study is to describe the MR arthrographic findings of this syndrome. Twenty-nine sets of MR arthrographic images were included in the study. Fourteen patients had adhesive capsulitis diagnosed by physical examination and arthrography, and their MR arthrographic findings were compared with those of 15 subjects in the control group. The images were retrospectively reviewed with specific attention to the thickness of the joint capsule, volume of the axillary pouch (length, width, height(depth)), thinkness of the coracohumeral ligament, presence of extra-articular contrast extravasation, and contrst filling of the subcoracoid bursa. Mean capsular thickness measured at the inferior portion of the axillary pouch was 4.1 mm in patients with adhesive capsulitis and 1.5 mm in the control group. The mean width of the axillary pouch was 2.5 mm in patients and 9.5 mm in controls. In patients, the capsule was significantly thicker and the axillary pouch significantly narrower than in controls (p<0.05). Capsule thickness greater than 2.5 mm at the inferior portion of the axillary pouch (sensitivity 93%, specificity 80%) and a pouch narrower than 3.5 mm (sensitivity 93%, specificity 100%) were useful criteria for the diagnosis of adhesive capsulitis. In patients with this condition, extra-articular contrast extravasation was noted in six patients (43%) and contrast filling of the subcoracoid bursa in three (21%). The MR arthrographic findings of adhesive capsulitis are capsular thickening, a low-volume axillary pouch, extra-articular contrast extravasation, and contrast filling of the subcoracoid bursa. Capsule thickness greater than 2.5 mm at the inferior portion of the axillary pouch and a pouch width of less than 3.5 mm are useful diagnostic imaging characteristics

  16. Complications of rotator cuff surgery—the role of post-operative imaging in patient care

    Science.gov (United States)

    Thakkar, R S; Thakkar, S C; Srikumaran, U; Fayad, L M

    2014-01-01

    When pain or disability occurs after rotator cuff surgery, post-operative imaging is frequently performed. Post-operative complications and expected post-operative imaging findings in the shoulder are presented, with a focus on MRI, MR arthrography (MRA) and CT arthrography. MR and CT techniques are available to reduce image degradation secondary to surgical distortions of native anatomy and implant-related artefacts and to define complications after rotator cuff surgery. A useful approach to image the shoulder after surgery is the standard radiography, followed by MRI/MRA for patients with low “metal presence” and CT for patients who have a higher metal presence. However, for the assessment of patients who have undergone surgery for rotator cuff injuries, imaging findings should always be correlated with the clinical presentation because post-operative imaging abnormalities do not necessarily correlate with symptoms. PMID:24734935

  17. Reducing Field Distortion in Magnetic Resonance Imaging

    Science.gov (United States)

    Eom, Byeong Ho; Penanen, Konstantin; Hahn, Inseob

    2010-01-01

    A concept for a magnetic resonance imaging (MRI) system that would utilize a relatively weak magnetic field provides for several design features that differ significantly from the corresponding features of conventional MRI systems. Notable among these features are a magnetic-field configuration that reduces (relative to the conventional configuration) distortion and blurring of the image, the use of a superconducting quantum interference device (SQUID) magnetometer as the detector, and an imaging procedure suited for the unconventional field configuration and sensor. In a typical application of MRI, a radio-frequency pulse is used to excite precession of the magnetic moments of protons in an applied magnetic field, and the decaying precession is detected for a short time following the pulse. The precession occurs at a resonance frequency proportional to the strengths of the magnetic field and the proton magnetic moment. The magnetic field is configured to vary with position in a known way; hence, by virtue of the aforesaid proportionality, the resonance frequency varies with position in a known way. In other words, position is encoded as resonance frequency. MRI using magnetic fields weaker than those of conventional MRI offers several advantages, including cheaper and smaller equipment, greater compatibility with metallic objects, and higher image quality because of low susceptibility distortion and enhanced spin-lattice-relaxation- time contrast. SQUID MRI is being developed into a practical MRI method for applied magnetic flux densities of the order of only 100 T

  18. Nuclear magnetic resonance spectroscopy and imaging

    International Nuclear Information System (INIS)

    Jiang Weiping; Wang Qi; Zhou Xin

    2013-01-01

    This paper briefly introduces the basic principle of nuclear magnetic resonance (NMR). Protein's structures and functions and dynamics studied by liquid NMR are elaborated; methods for enhancing the resolution of solid state NMR and its applications are discussed; the principle of magnetic resonance imaging (MRI) is interpreted, and applications in different aspects are reviewed. Finally, the progress of NMR is commented. (authors)

  19. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... structures of the brain and can also provide functional information (fMRI) in selected cases. MR images of ... Articles and Media MR Angiography (MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain ...

  20. Lymphoma of uterine cervix: magnetic resonance imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Kanaan, Daniel; Constantino, Carolina Pesce Lamas; Souza, Rodrigo Canellas de, E-mail: daniel.kanaan@hotmail.com [Department of Radiology, Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil); Parente, Daniella Braz [Instituto D' Or de Pesquisa e Ensino, Rio de Janeiro, RJ (Brazil)

    2012-05-15

    Lymphoma of the cervix is a rare disease. About 1.0% to 1.5% of extranodal lymphomas originates in the female genital tract. The clinical presentation of this condition is nonspecific and magnetic resonance imaging is important for diagnostic elucidation. The present report describes the case of a 80-year-old patient with lumbar pain, whose magnetic resonance imaging showed a large uterine mass. The final diagnosis was lymphoma. (author)

  1. Pocket atlas of cranial magnetic resonance imaging

    International Nuclear Information System (INIS)

    Haughton, V.M.; Daniels, D.L.

    1986-01-01

    This atlas illustrates normal cerebral anatomy in magnetic resonance images. From their studies in cerebral anatomy utilizing cryomicrotome and other techniques, the authors selected more than 100 high-resolution images that represent the most clinically useful scans

  2. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Magnetic Resonance Imaging Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ... links: For the convenience of our users, RadiologyInfo .org provides links to relevant websites. RadiologyInfo.org , ACR ...

  3. Parallel magnetic resonance imaging

    International Nuclear Information System (INIS)

    Larkman, David J; Nunes, Rita G

    2007-01-01

    Parallel imaging has been the single biggest innovation in magnetic resonance imaging in the last decade. The use of multiple receiver coils to augment the time consuming Fourier encoding has reduced acquisition times significantly. This increase in speed comes at a time when other approaches to acquisition time reduction were reaching engineering and human limits. A brief summary of spatial encoding in MRI is followed by an introduction to the problem parallel imaging is designed to solve. There are a large number of parallel reconstruction algorithms; this article reviews a cross-section, SENSE, SMASH, g-SMASH and GRAPPA, selected to demonstrate the different approaches. Theoretical (the g-factor) and practical (coil design) limits to acquisition speed are reviewed. The practical implementation of parallel imaging is also discussed, in particular coil calibration. How to recognize potential failure modes and their associated artefacts are shown. Well-established applications including angiography, cardiac imaging and applications using echo planar imaging are reviewed and we discuss what makes a good application for parallel imaging. Finally, active research areas where parallel imaging is being used to improve data quality by repairing artefacted images are also reviewed. (invited topical review)

  4. Magnetic resonance imaging findings in patients with Hallervorden-Spatz syndrome

    International Nuclear Information System (INIS)

    Nomura, Cesar Higa; Lima, Eduardo Carneiro; Cerri, Giovanni Guido; Leite, Claudia da Costa; Rosemberg, Sergio

    2003-01-01

    The objective of this study was to review the magnetic resonance imaging findings in patients with Hallervorden-Spatz syndrome. We evaluated eight patients with Hallervorden-Spatz syndrome using magnetic resonance imaging. The protocol included at least sagittal and axial T1-weighted images and axial and coronal T2-weighted images. Intravenous gadolinium was administered in a dose of 0.1 mmol/kg. Post-enhanced images were obtained at least in the axial and coronal planes. The results were: all patients presented a bilateral and symmetrical 'tiger-eye signal' on T2-weighted images, corresponding to central hyperintensity and peripheral hypointensity in the globi pallidus. FLAIR and diffusion images showed similar abnormalities. There was no gadolinium enhancement in any of the cases. We concluded that magnetic resonance imaging findings in patients with Hallervorden-Spatz syndrome are very typical and allow the diagnosis of the disease. (author)

  5. Resonant Mode Reduction in Radiofrequency Volume Coils for Ultrahigh Field Magnetic Resonance Imaging

    Directory of Open Access Journals (Sweden)

    Xiaoliang Zhang

    2011-07-01

    Full Text Available In a multimodal volume coil, only one mode can generate homogeneous Radiofrequency (RF field for Magnetic Resonance Imaging. The existence of other modes may increase the volume coil design difficulties and potentially decreases coil performance. In this study, we introduce common-mode resonator technique to high and ultrahigh field volume coil designs to reduce the resonant mode while maintain the homogeneity of the RF field. To investigate the design method, the common-mode resonator was realized by using a microstrip line which was split along the central to become a pair of parallel transmission lines within which common-mode currents exist. Eight common-mode resonators were placed equidistantly along the circumference of a low loss dielectric cylinder to form a volume coil. Theoretical analysis and comparison between the 16-strut common-mode volume coil and a conventional 16-strut volume coil in terms of RF field homogeneity and efficiency was performed using Finite-Difference Time-Domain (FDTD method at 298.2 MHz. MR imaging experiments were performed by using a prototype of the common-mode volume coil on a whole body 7 Tesla scanner. FDTD simulation results showed the reduced number of resonant modes of the common-mode volume coil over the conventional volume coil, while the RF field homogeneity of the two type volume coils was kept at the same level. MR imaging of a water phantom and a kiwi fruit showing the feasibility of the proposed method for simplifying the volume coil design is also presented.

  6. CT arthrography of the wrist using a novel, mobile, dedicated extremity cone-beam CT (CBCT)

    Energy Technology Data Exchange (ETDEWEB)

    Koskinen, Seppo K. [Helsinki University Central Hospital, Department of Radiology, HUS Helsinki Medical Imaging Center, Helsinki (Finland); Helsinki University Hospital, Toeoeloe Trauma Center, Department of Radiology, HUS Helsinki Medical Imaging Center, Helsinki (Finland); Haapamaeki, Ville V.; Kortesniemi, Mika [Helsinki University Central Hospital, Department of Radiology, HUS Helsinki Medical Imaging Center, Helsinki (Finland); Salo, Jari [Helsinki University Central Hospital, Department of Orthopedic and Trauma Surgery, Helsinki (Finland); Kuopio University Hospital, UEF, Department of Orthopedics, Traumatology and Hand Surgery, Kuopio (Finland); Lindfors, Nina C. [Helsinki University Central Hospital, Department of Orthopedic and Hand Surgery, Helsinki (Finland); Seppaelae, Lauri [Planmed Oy, Helsinki (Finland); Mattila, Kimmo T. [Turku University Central Hospital, Department of Diagnostic Radiology, Turku (Finland)

    2013-05-15

    To evaluate the feasibility and intra- and interobserver agreement of CBCT arthrography of wrist ligaments, triangular fibrocartilaginous complex (TFCC), and to assess the sensitivity (SE), specificity (SP), accuracy (ACC), and positive and negative predictive value (PPV, NPV) of CBCT arthrography in the diagnosis of scapholunate (SLL) and lunotriquetral (LTL) ligament tears, TFCC, and cartilage abnormalities of the scaphoid and lunate with their corresponding radial surfaces (scaphoid and lunate fossa) using a novel, mobile, dedicated extremity CBCT scanner. Fifty-two consecutively enrolled subjects (26 M, 26 F, mean age 38 years, range 18-66 years) with suspected wrist ligament tears underwent CBCT-arthrography before normally scheduled MR arthrography.An extremity CBCT was used for imaging with isotropic voxel size of 0.4 x 0.4 x 0.4 mm{sup 3}. Subsequent routine 1.5 T MRI was performed using a dedicated wrist coil.Two observers reviewed the anonymized CBCT images twice for contrast enhancement (CE) and technical details (TD), for tears of the SLL, LTL, and TFCC. Also, cartilage abnormalities of the scaphoid and lunate with their corresponding radial surfaces (scaphoid and lunate fossa) were evaluated. Inter- and intraobserver agreement was determined using weighted kappa statistics. Since no surgery was performed, MRI served as a reference standard, and SE and SP, ACC, PPV, and NPV were calculated. Intra- and interobserver kappa values for both readers (reader 1/reader 2; first reading/second reading) with 95 % confidence limits were: CE 0.54 (0.08-1.00)/ 0.75 (0.46-1.00); 0.73 (0.29-1.00)/ 0.45 (0.07-0.83), TD 0.53 (0.30-0.88)/ 0.86 (0.60-1.00); 0.56 (0.22-0.91)/ 0.67 (0.37-0.98), SLL 0.59 (0.25-0.93)/ 0.66 (0.42-0.91); 0.31 (0.06-0.56)/ 0.49 (0.26-0.73), LTL 0.83 (0.66-1.00)/ 0.68 (0.46-0.91); 0.90 (0.79-1.00)/ 0.48 (0.22-0.74); TFCC (0.72-1.00)/ (0.79-1.00); 0.65 (0.43-0.87)/ 0.59 (0.35-0.83), radius (scaphoid fossa) 0.45 (0.12-0.77)/ 0.64 (0.31-0.96); 0

  7. Can symptomatic acromioclavicular joints be differentiated from asymptomatic acromioclavicular joints on 3-T MR imaging?

    Science.gov (United States)

    Choo, Hye Jung; Lee, Sun Joo; Kim, Jung Han; Cha, Seong Sook; Park, Young Mi; Park, Ji Sung; Lee, Jun Woo; Oh, Minkyung

    2013-04-01

    To evaluate retrospectively whether symptomatic acromioclavicular joints can be differentiated from asymptomatic acromioclavicular joints on 3-T MR imaging. This study included 146 patients who underwent physical examination of acromioclavicular joints and 3-T MR imaging of the shoulder. Among them, 67 patients showing positive results on physical examination were assigned to the symptomatic group, whereas 79 showing negative results were assigned to the asymptomatic group. The following MR findings were compared between the symptomatic and asymptomatic groups: presence of osteophytes, articular surface irregularity, subchondral cysts, acromioclavicular joint fluid, subacromial fluid, subacromial bony spurs, joint capsular distension, bone edema, intraarticular enhancement, periarticular enhancement, superior and inferior joint capsular distension degree, and joint capsular thickness. The patients were subsequently divided into groups based on age (younger, older) and the method of MR arthrography (direct MR arthrography, indirect MR arthrography), and all the MR findings in each subgroup were reanalyzed. The meaningful cutoff value of each significant continuous variable was calculated using receiver operating characteristic analysis. The degree of superior capsular distension was the only significant MR finding of symptomatic acromioclavicular joints and its meaningful cutoff value was 2.1mm. After subgroup analyses, this variable was significant in the older age group and indirect MR arthrography group. On 3-T MR imaging, the degree of superior joint capsular distension might be a predictable MR finding in the diagnosis of symptomatic acromioclavicular joints. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  8. Unusual Presentation of Popliteal Cyst on Magnetic Resonance Imaging

    Directory of Open Access Journals (Sweden)

    Tsuyoshi Ohishi

    2016-01-01

    Full Text Available Popliteal cyst commonly presents as an ellipsoid mass with uniform low signal intensity on T1-weighted magnetic resonance images and high signal intensity on T2-weighted images. Here, we describe a popliteal cyst with unusual appearance on magnetic resonance imaging, including heterogeneous intermediate signal intensity on T2-weighted images. Arthroscopic cyst decompression revealed that the cyst was filled with necrotic synovial villi, indicative of rheumatoid arthritis. Arthroscopic enlargement of unidirectional valvular slits with synovectomy was useful for the final diagnosis and treatment.

  9. C-arm flat-panel CT arthrography of the shoulder: Radiation dose considerations and preliminary data on diagnostic performance

    International Nuclear Information System (INIS)

    Guggenberger, Roman; Ulbrich, Erika J.; Kaelin, Pascal; Pfammatter, Thomas; Alkadhi, Hatem; Andreisek, Gustav; Dietrich, Tobias J.; Scholz, Rosemarie; Koehler, Christoph; Elsaesser, Thilo; Le Corroller, Thomas

    2017-01-01

    To investigate radiation dose and diagnostic performance of C-arm flat-panel CT (FPCT) versus standard multi-detector CT (MDCT) shoulder arthrography using MRI-arthrography as reference standard. Radiation dose of two different FPCT acquisitions (5 and 20 s) and standard MDCT of the shoulder were assessed using phantoms and thermoluminescence dosimetry. FPCT arthrographies were performed in 34 patients (mean age 44 ± 15 years). Different joint structures were quantitatively and qualitatively assessed by two independent radiologists. Inter-reader agreement and diagnostic performance were calculated. Effective radiation dose was markedly lower in FPCT 5 s (0.6 mSv) compared to MDCT (1.7 mSv) and FPCT 20 s (3.4 mSv). Contrast-to-noise ratios (CNRs) were significantly (p < 0.05) higher in FPCT 20-s versus 5-s protocols. Inter-reader agreements of qualitative ratings ranged between κ = 0.47-1.0. Sensitivities for cartilage and rotator cuff pathologies were low for FPCT 5-s (40 % and 20 %) and moderate for FPCT 20-s protocols (75 % and 73 %). FPCT showed high sensitivity (81-86 % and 89-99 %) for bone and acromioclavicular-joint pathologies. Using a 5-s protocol FPCT shoulder arthrography provides lower radiation dose compared to MDCT but poor sensitivity for cartilage and rotator cuff pathologies. FPCT 20-s protocol is moderately sensitive for cartilage and rotator cuff tendon pathology with markedly higher radiation dose compared to MDCT. (orig.)

  10. C-arm flat-panel CT arthrography of the shoulder: Radiation dose considerations and preliminary data on diagnostic performance

    Energy Technology Data Exchange (ETDEWEB)

    Guggenberger, Roman; Ulbrich, Erika J.; Kaelin, Pascal; Pfammatter, Thomas; Alkadhi, Hatem; Andreisek, Gustav [University Hospital Zurich, Institute of Diagnostic and Interventional Radiology, Zuerich (Switzerland); Dietrich, Tobias J. [Balgrist University Hospital, Department of Radiology, Zurich (Switzerland); Scholz, Rosemarie; Koehler, Christoph; Elsaesser, Thilo [Siemens Healthcare GmbH, Business Area Advanced Therapies, Forchheim (Germany); Le Corroller, Thomas [Aix-Marseille Universite, CNRS, ISM UMR 7287, Marseille (France); Radiology Department, APHM, Marseille (France)

    2017-02-15

    To investigate radiation dose and diagnostic performance of C-arm flat-panel CT (FPCT) versus standard multi-detector CT (MDCT) shoulder arthrography using MRI-arthrography as reference standard. Radiation dose of two different FPCT acquisitions (5 and 20 s) and standard MDCT of the shoulder were assessed using phantoms and thermoluminescence dosimetry. FPCT arthrographies were performed in 34 patients (mean age 44 ± 15 years). Different joint structures were quantitatively and qualitatively assessed by two independent radiologists. Inter-reader agreement and diagnostic performance were calculated. Effective radiation dose was markedly lower in FPCT 5 s (0.6 mSv) compared to MDCT (1.7 mSv) and FPCT 20 s (3.4 mSv). Contrast-to-noise ratios (CNRs) were significantly (p < 0.05) higher in FPCT 20-s versus 5-s protocols. Inter-reader agreements of qualitative ratings ranged between κ = 0.47-1.0. Sensitivities for cartilage and rotator cuff pathologies were low for FPCT 5-s (40 % and 20 %) and moderate for FPCT 20-s protocols (75 % and 73 %). FPCT showed high sensitivity (81-86 % and 89-99 %) for bone and acromioclavicular-joint pathologies. Using a 5-s protocol FPCT shoulder arthrography provides lower radiation dose compared to MDCT but poor sensitivity for cartilage and rotator cuff pathologies. FPCT 20-s protocol is moderately sensitive for cartilage and rotator cuff tendon pathology with markedly higher radiation dose compared to MDCT. (orig.)

  11. Free radicals imaged in vivo in the rat by using proton-electron double-resonance imaging

    International Nuclear Information System (INIS)

    Lurie, D.J.; Nicholson, Ian; Foster, M.A.; Mallard, J.R.

    1990-01-01

    A new technique called proton-electron double-resonance imaging is described for imaging free radicals in aqueous samples. The method is a combination of proton NMR imaging with nuclear electron double resonance. The results of using this technique to image free radicals in vivo in the rat are presented. Rats were injected intravenously with a nitroxide free radical solution and a series of images was obtained from which the clearance of the free radical through the liver and kidneys could be observed. (author)

  12. Nuclear magnetic resonance imaging

    International Nuclear Information System (INIS)

    1983-06-01

    This report summarises the aspects of nuclear magnetic resonance imaging (NMRI) considered by the National Health Technology Advisory Panel and makes recommendations on its introduction in Australia with particular regard to the need for thorough evaluation of its cost effectiveness. Topics covered are: principles of the technique, equipment required, installation, costs, reliability, performance parameters, clinical indications, training and staff requirements, and safety considerations

  13. Imaging of hip arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Theodore T., E-mail: millertt@hss.edu [Department of Radiology and Imaging, Hospital for Special Surgery, 535 E. 70th Street, New York, NY 10021 (United States)

    2012-12-15

    The imaging evaluation of the prosthetic hip begins with radiography, but arthrography, aspiration, scintigraphy, sonography, CT and MR imaging all have roles in the evaluation of the painful prosthesis. This article will review the appearance of normal hip arthroplasty including hemiarthroplasty, total arthroplasty, and hip resurfacing, as well as the appearances of potential complications such as aseptic loosening and osteolysis, dislocation, infection, periprosthetic fracture, hardware failure, and soft tissue abnormalities.

  14. Magnetic resonance imaging of vulnerable atherosclerotic plaques: current imaging strategies and molecular imaging probes

    NARCIS (Netherlands)

    Briley-Saebo, Karen C.; Mulder, Willem J. M.; Mani, Venkatesh; Hyafil, Fabien; Amirbekian, Vardan; Aguinaldo, Juan Gilberto S.; Fisher, Edward A.; Fayad, Zahi A.

    2007-01-01

    The vulnerability or destabilization of atherosclerotic plaques has been directly linked to plaque composition. Imaging modalities, such as magnetic resonance (MR) imaging, that allow for evaluation of plaque composition at a cellular and molecular level, could further improve the detection of

  15. Structural magnetic resonance imaging in epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Deblaere, Karel [Ghent University Hospital, Department of Neuroradiology, Ghent (Belgium); Ghent University Hospital, MR Department - 1K12, Ghent (Belgium); Achten, Eric [Ghent University Hospital, Department of Neuroradiology, Ghent (Belgium)

    2008-01-15

    Because of its sensitivity and high tissue contrast, magnetic resonance imaging (MRI) is the technique of choice for structural imaging in epilepsy. In this review the effect of using optimised scanning protocols and the use of high field MR systems on detection sensitivity is discussed. Also, the clinical relevance of adequate imaging in patients with focal epilepsy is highlighted. The most frequently encountered MRI findings in epilepsy are reported and their imaging characteristics depicted. Imaging focus will be on the diagnosis of hippocampal sclerosis and malformations of cortical development, two major causes of medically intractable focal epilepsy. (orig.)

  16. Structural magnetic resonance imaging in epilepsy

    International Nuclear Information System (INIS)

    Deblaere, Karel; Achten, Eric

    2008-01-01

    Because of its sensitivity and high tissue contrast, magnetic resonance imaging (MRI) is the technique of choice for structural imaging in epilepsy. In this review the effect of using optimised scanning protocols and the use of high field MR systems on detection sensitivity is discussed. Also, the clinical relevance of adequate imaging in patients with focal epilepsy is highlighted. The most frequently encountered MRI findings in epilepsy are reported and their imaging characteristics depicted. Imaging focus will be on the diagnosis of hippocampal sclerosis and malformations of cortical development, two major causes of medically intractable focal epilepsy. (orig.)

  17. Meniscal configuration using magnetic resonance imaging; Configuracao meniscal pela ressonancia magnetica

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Arthur da Rocha C.; Turrini, Elisabete; Karoauk, Teresa C.C.; Lederman, Henrique M. [Escola Paulista de Medicina, Sao Paulo, SP (Brazil). Dept. de Diagnostico por Imagem

    1997-04-01

    The authors present a review of the normal meniscal configuration and correlation with anatomic specimens. The images were obtained by magnetic resonance imaging. The images were obtained by magnetic resonance imaging. The authors emphasize the importance of knowing the relationship between the meniscus and the adjacent anatomic structures. (author) 31 refs., 10 figs., tabs.

  18. Magnetic resonance imaging of the normal equine digit and metacarpophalangeal joint

    International Nuclear Information System (INIS)

    Park, R.D.; Nelson, T.R.; Hoopes, P.J.

    1987-01-01

    Magnetic resonance (MR) images were made in sagittal and transverse planes through the metacarpophalangeal joint and digit of a horse. The images accurately depicted gross anatomic structures in the leg. Soft tissue structures were defined as separate entities on the images. Histologic variation in tissues correlated with signal intensity differences on the MR images. Magnetic resonance imaging appears to be a promising imaging modality for evaluating musculoskeletal structures in equine limbs

  19. Magnetic resonance spectroscopy as an imaging method

    International Nuclear Information System (INIS)

    Bomsdorf, H.; Imme, M.; Jensen, D.; Kunz, D.; Menhardt, W.; Ottenberg, K.; Roeschmann, P.; Schmidt, K.H.; Tschendel, O.; Wieland, J.

    1990-01-01

    An experimental Magnetic Resonance (MR) system with 4 tesla flux density was set up. For that purpose a data acquisition system and RF coils for resonance frequencies up to 170 MHz were developed. Methods for image guided spectroscopy as well as spectroscopic imaging focussing on the nuclei 1 H and 13 C were developed and tested on volunteers and selected patients. The advantages of the high field strength with respect to spectroscopic studies were demonstrated. Developments of a new fast imaging technique for the acquisition of scout images as well as a method for mapping and displaying the magnetic field inhomogeneity in-vivo represent contributions to the optimisation of the experimental procedure in spectroscopic studies. Investigations on the interaction of RF radiation with the exposed tissue allowed conclusions regarding the applicability of MR methods at high field strengths. Methods for display and processing of multi-dimensional spectroscopic imaging data sets were developed and existing methods for real-time image synthesis were extended. Results achieved in the field of computer aided analysis of MR images comprised new techniques for image background detection, contour detection and automatic image interpretation as well as knowledge bases for textural representation of medical knowledge for diagnosis. (orig.) With 82 refs., 3 tabs., 75 figs [de

  20. Clinical magnetic resonance: imaging and spectroscopy

    International Nuclear Information System (INIS)

    Andrew, E.R.; Bydder, Graeme; Griffiths, John; Iles, Richard; Styles, Peter

    1990-01-01

    This book begins with a readable, comprehensive but non-mathematical introduction to the basic underlying principles of magnetic resonance. Further chapters include information on the theory and principles of MRI and MRS, the interpretation of MR images, the clinical applications and scope of MRI and MRS, practical aspects of spectroscopy and magnetic resonance, and also the practical problems associated with the siting, safety and operation of large MRI and MRS equipment. (author)

  1. Far-field superresolution by imaging of resonance scattering

    KAUST Repository

    Schuster, Gerard T.; Huang, Y.

    2014-01-01

    We show that superresolution imaging in the far-field region of the sources and receivers is theoretically and practically possible if migration of resonant multiples is employed. A resonant multiple is one that bounces back and forth between two

  2. Prebiopsy magnetic resonance spectroscopy and imaging in the diagnosis of prostate cancer

    International Nuclear Information System (INIS)

    Kumar, V.; Jagannathan, N.R.; Thulkar, S.; Kumar, R.

    2012-01-01

    Existing screening investigations for the diagnosis of early prostate cancer lack specificity, resulting in a high negative biopsy rate. There is increasing interest in the use of various magnetic resonance methods for improving the yield of transrectal ultrasound-guided biopsies of the prostate in men suspected to have prostate cancer. We review the existing status of such investigations. A literature search was carried out using the Pubmed database to identify articles related to magnetic resonance methods for diagnosing prostate cancer. References from these articles were also extracted and reviewed. Recent studies have focused on prebiopsy magnetic resonance investigations using conventional magnetic resonance imaging, dynamic contrast enhanced magnetic resonance imaging, diffusion weighted magnetic resonance imaging, magnetization transfer imaging and magnetic resonance spectroscopy of the prostate. This marks a shift from the earlier strategy of carrying out postbiopsy magnetic resonance investigations. Prebiopsy magnetic resonance investigations has been useful in identifying patients who are more likely to have a biopsy positive for malignancy. Prebiopsy magnetic resonance investigations has a potential role in increasing specificity of screening for early prostate cancer. It has a role in the targeting of biopsy sites, avoiding unnecessary biopsies and predicting the outcome of biopsies. (author)

  3. Magnetic resonance imaging in obstetric diagnosis.

    Science.gov (United States)

    Weinreb, J C; Lowe, T W; Santos-Ramos, R; Cunningham, F G; Parkey, R

    1985-01-01

    Five patients with abnormal pregnancies were examined with ultrasound (US) and magnetic resonance imaging (MR). Three had a malformed fetus, 1 had a molar pregnancy, and 1 had an ovarian mass. Both maternal and fetal structures were clearly shown, although fetal motion may have resulted in image degradation in some cases. The authors suggest that MR may be useful in obstetric diagnosis.

  4. Magnetic resonance imaging of semicircular canals.

    Science.gov (United States)

    Sbarbati, A; Leclercq, F; Zancanaro, C; Antonakis, K

    1992-01-01

    The present paper reports the results of the first investigation of the semicircular canals in a living, small animal by means of high spatial resolution magnetic resonance imaging. This procedure is noninvasive and allows identification of the endolymphatic and perilymphatic spaces yielding a morphology quite consistent with direct anatomical examination. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 PMID:1506290

  5. The introduction of clinical magnetic resonance imaging in Australia

    International Nuclear Information System (INIS)

    Sorby, W.; Baddeley, H.

    1986-01-01

    Magnetic resonance imaging is a new, but expensive, modality that is being introduced into clinical use in Australia. While it promises increased safety and accuracy in many situations, its precise role when compared with computed tomography and other modalities is not fully established. Therefore, a Government financed evaluation of costs and efficacy of magnetic resonance imaging units in five teaching hospitals is to be conducted over two years (1986-1988). Experience with the introduction of computed tomography to Australia and other nations has revealed difficulties in the evaluation by conventional methods of a diagnostic technology that is improving rapidly; it is to be hoped that a systematic evaluation of the clinical applications of magnetic resonance imaging will be more achievable and useful

  6. Brain Imaging Using Hyperpolarized 129Xe Magnetic Resonance Imaging.

    Science.gov (United States)

    Chahal, Simrun; Prete, Braedan R J; Wade, Alanna; Hane, Francis T; Albert, Mitchell S

    2018-01-01

    Hyperpolarized (HP) 129 Xe magnetic resonance imaging (MRI) is a novel iteration of traditional MRI that relies on detecting the spins of 1 H. Since 129 Xe is a gaseous signal source, it can be used for lung imaging. Additionally, 129 Xe dissolves in the blood stream and can therefore be detectable in the brain parenchyma and vasculature. In this work, we provide detailed information on the protocols that we have developed to image 129 Xe within the brains of both rodents and human subjects. © 2018 Elsevier Inc. All rights reserved.

  7. Magnetic resonance imaging in neuroradiology

    International Nuclear Information System (INIS)

    Voigt, K.; Lotx, J.W.

    1990-01-01

    Magnetic resonance imaging (MRI) is now accepted as an effective method of investigating a wide range of disorders, especially of the brain and spine. A short introduction on image contrast in MRI is given and the advantages and disadvantages for the different diseases of the brain is discussed. Excellent soft-tissue contrast, multiplanar imaging capabilities and lack of ionising radiation are conspicuous advantages, and it is now established as the investigation of choice in a large number of clinical conditions, especially when the central nervous system is involved. However, it remains only one of a series of imaging modalities. A confident provisional clinical diagnosis is essential for establishing an imaging protocol and the intention should always be to reach a definitive diagnosis in the least invasive and most cost-effective way. 7 figs., 19 refs

  8. Magnetic Resonance Imaging of Liver Metastasis.

    Science.gov (United States)

    Karaosmanoglu, Ali Devrim; Onur, Mehmet Ruhi; Ozmen, Mustafa Nasuh; Akata, Deniz; Karcaaltincaba, Musturay

    2016-12-01

    Liver magnetic resonance imaging (MRI) is becoming the gold standard in liver metastasis detection and treatment response assessment. The most sensitive magnetic resonance sequences are diffusion-weighted images and hepatobiliary phase images after Gd-EOB-DTPA. Peripheral ring enhancement, diffusion restriction, and hypointensity on hepatobiliary phase images are hallmarks of liver metastases. In patients with normal ultrasonography, computed tomography (CT), and positron emission tomography (PET)-CT findings and high clinical suspicion of metastasis, MRI should be performed for diagnosis of unseen metastasis. In melanoma, colon cancer, and neuroendocrine tumor metastases, MRI allows confident diagnosis of treatment-related changes in liver and enables differential diagnosis from primary liver tumors. Focal nodular hyperplasia-like nodules in patients who received platinum-based chemotherapy, hypersteatosis, and focal fat can mimic metastasis. In cancer patients with fatty liver, MRI should be preferred to CT. Although the first-line imaging for metastases is CT, MRI can be used as a problem-solving method. MRI may be used as the first-line method in patients who would undergo curative surgery or metastatectomy. Current limitation of MRI is low sensitivity for metastasis smaller than 3mm. MRI fingerprinting, glucoCEST MRI, and PET-MRI may allow simpler and more sensitive diagnosis of liver metastasis. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. A radiologist's guide to the imaging in the diagnosis and treatment of developmental dysplasia of the hip. Pt. 1. General considerations, physical examination as applied to real-time sonography and radiography

    International Nuclear Information System (INIS)

    Gerscovich, E.O.

    1997-01-01

    Developmental dysplasia of the hip (DDH) has a broad spectrum of presentation with the minor findings resolving spontaneously and the most severe ones resulting in disability, if not diagnosed early in life. Diagnosis in the first few months of life allows conservative treatment with complete resolution in most cases. Suspicion of DDH is based on ethnic, family, and pregnancy history, and on physical examination of the newborn. Imaging assists in the diagnosis and follows the treatment. Different modalities have their own advantages and disadvantages. This article deals with the description of the disease, risk factors, statistics, the physical examination as applied to real-time sonography, and imaging (plain radiography, arthrography, computed tomography, and magnetic resonance imaging). (orig.). With 26 figs., 1 tab

  10. Assessment of coronary artery disease with nicorandil stress magnetic resonance imaging

    International Nuclear Information System (INIS)

    Kawase, Yoshio; Nichimoto, Masaki; Hato, Katsunori; Okajima, Kazue; Yoshikawa, Junichi

    2004-01-01

    Although dipyridamole and adenosine have been used as vasodilator agents, we believe they are inadequate for vasodilator perfusion magnetic resonance imaging, due to adverse effects (flushing, warmth, headaches, and arrhythmia). Nicorandil, a potassium channel opener, has been reported to increase coronary blood flow and it was associated with fewer adverse effects than adenosine or dipiridamole. We set out to investigate whether the coronary artery stenosis could be assessed by nicorandil stress perfusion magnetic resonance imaging. First-pass contrast-enhanced magnetic resonance images of the left ventricle acquired from 50 patients at rest and during intravenous administration of nicorandil using multi-slice turbo field echo with multi shot echo-planar-imaging. Coronary angiography was performed within 1 week. There was no adverse effects during nicorandil stress in any patients. The overall sensitivity and specificity of magnetic resonance imaging in identifying patients with significant stenosis of at least one coronary artery were 93.9% (31 of 33 patients) and 94.1% (16 of 17 patients), respectively. The sensitivity of magnetic resonance imaging for detecting significant stenosis in the left anterior descending artery was 87.5%; the sensitivity in the left circumflex artery was 80%; the sensitivity in the right coronary artery was 92.3%. Similar sensitivities were observed for all 3 vascular regions, indicating that all myocardial segments were visualized with similar image quality. The present study shows that nicorandil stress perfusion magnetic resonance imaging is a safe, feasible technique for assessing coronary artery stenosis severity in a totally-noninvasive manner. (authors)

  11. Adjunctive role of preoperative liver magnetic resonance imaging for potentially resectable pancreatic cancer.

    Science.gov (United States)

    Kim, Hyoung Woo; Lee, Jong-Chan; Paik, Kyu-Hyun; Kang, Jingu; Kim, Young Hoon; Yoon, Yoo-Seok; Han, Ho-Seong; Kim, Jaihwan; Hwang, Jin-Hyeok

    2017-06-01

    The adjunctive role of magnetic resonance imaging of the liver before pancreatic ductal adenocarcinoma has been unclear. We evaluated whether the combination of hepatic magnetic resonance imaging with multidetector computed tomography using a pancreatic protocol (pCT) could help surgeons select appropriate candidates and decrease the risk of early recurrence. We retrospectively enrolled 167 patients in whom complete resection was achieved without grossly visible residual tumor; 102 patients underwent pCT alone (CT group) and 65 underwent both hepatic magnetic resonance imaging and pCT (magnetic resonance imaging group). By adding hepatic magnetic resonance imaging during preoperative evaluation, hepatic metastases were newly discovered in 3 of 58 patients (5%) without hepatic lesions on pCT and 17 of 53 patients (32%) with indeterminate hepatic lesions on pCT. Patients with borderline resectability, a tumor size >3 cm, or preoperative carbohydrate antigen 19-9 level >1,000 U/mL had a greater rate of hepatic metastasis on subsequent hepatic magnetic resonance imaging. Among 167 patients in whom R0/R1 resection was achieved, the median overall survival was 18.2 vs 24.7 months (P = .020) and the disease-free survival was 8.5 vs 10.0 months (P = .016) in the CT and magnetic resonance imaging groups, respectively (median follow-up, 18.3 months). Recurrence developed in 82 (80%) and 43 (66%) patients in the CT and magnetic resonance imaging groups, respectively. The cumulative hepatic recurrence rate was greater in the CT group than in the magnetic resonance imaging group (P magnetic resonance imaging should be considered in patients with potentially resectable pancreatic ductal adenocarcinoma, especially those with high tumor burden. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Automated Segmentation of Cardiac Magnetic Resonance Images

    DEFF Research Database (Denmark)

    Stegmann, Mikkel Bille; Nilsson, Jens Chr.; Grønning, Bjørn A.

    2001-01-01

    Magnetic resonance imaging (MRI) has been shown to be an accurate and precise technique to assess cardiac volumes and function in a non-invasive manner and is generally considered to be the current gold-standard for cardiac imaging [1]. Measurement of ventricular volumes, muscle mass and function...

  13. Smart Contrast Agents for Magnetic Resonance Imaging.

    Science.gov (United States)

    Bonnet, Célia S; Tóth, Éva

    2016-01-01

    By visualizing bioactive molecules or biological parameters in vivo, molecular imaging is searching for information at the molecular level in living organisms. In addition to contributing to earlier and more personalized diagnosis in medicine, it also helps understand and rationalize the molecular factors underlying physiological and pathological processes. In magnetic resonance imaging (MRI), complexes of paramagnetic metal ions, mostly lanthanides, are commonly used to enhance the intrinsic image contrast. They rely either on the relaxation effect of these metal chelates (T(1) agents), or on the phenomenon of paramagnetic chemical exchange saturation transfer (PARACEST agents). In both cases, responsive molecular magnetic resonance imaging probes can be designed to report on various biomarkers of biological interest. In this context, we review recent work in the literature and from our group on responsive T(1) and PARACEST MRI agents for the detection of biogenic metal ions (such as calcium or zinc), enzymatic activities, or neurotransmitter release. These examples illustrate the general strategies that can be applied to create molecular imaging agents with an MRI detectable response to biologically relevant parameters.

  14. Imaging prostate cancer: an update on positron emission tomography and magnetic resonance imaging

    DEFF Research Database (Denmark)

    Bouchelouche, Kirsten; Turkbey, Baris; Choyke, Peter

    2010-01-01

    , and molecular imaging information. Developments in imaging technologies, specifically magnetic resonance imaging (MRI) and positron emission tomography (PET)/computed tomography (CT), have improved the detection rate of prostate cancer. MRI has improved lesion detection and local staging. Furthermore, MRI...

  15. A radiologist`s guide to the imaging in the diagnosis and treatment of developmental dysplasia of the hip. Pt. 1. General considerations, physical examination as applied to real-time sonography and radiography

    Energy Technology Data Exchange (ETDEWEB)

    Gerscovich, E.O. [Department of Radiology, University of California, Davis Medical Center, 2516 Stockton Blvd., Ticon II Building, Sacramento, CA 95817 (United States)

    1997-07-07

    Developmental dysplasia of the hip (DDH) has a broad spectrum of presentation with the minor findings resolving spontaneously and the most severe ones resulting in disability, if not diagnosed early in life. Diagnosis in the first few months of life allows conservative treatment with complete resolution in most cases. Suspicion of DDH is based on ethnic, family, and pregnancy history, and on physical examination of the newborn. Imaging assists in the diagnosis and follows the treatment. Different modalities have their own advantages and disadvantages. This article deals with the description of the disease, risk factors, statistics, the physical examination as applied to real-time sonography, and imaging (plain radiography, arthrography, computed tomography, and magnetic resonance imaging). (orig.). With 26 figs., 1 tab.

  16. Comparison of three-dimensional isotropic and conventional MR arthrography with respect to the diagnosis of rotator cuff and labral lesions: Focus on isotropic fat-suppressed proton density and VIBE sequences

    International Nuclear Information System (INIS)

    Park, S.Y.; Lee, I.S.; Park, S.K.; Cheon, S.J.; Ahn, J.M.; Song, J.W.

    2014-01-01

    Aim: To compare the diagnostic accuracies of three-dimensional (3D) isotropic magnetic resonance arthrography (MRA) using fat-suppressed proton density (PD) or volume interpolated breath-hold examination (VIBE) sequences with that of conventional MRA for the diagnosis of rotator cuff and labral lesions. Materials and methods: Eighty-six patients who underwent arthroscopic surgery were included. 3D isotropic sequences were performed in the axial plane using fat-suppressed PD (group A) in 53 patients and using VIBE (group B) in 33 patients. Reformatted images were obtained corresponding to conventional images, and evaluated for the presence of labral and rotator cuff lesions using conventional and 3D isotropic sequences. The diagnostic performances of each sequence were determined using arthroscopic findings as the standard. Results: Good to excellent interobserver agreements were obtained for both 3D isotropic sequences for the evaluation of rotator cuff and labral lesions. Excellent agreement was found between two-dimensional (2D) and 3D isotropic MRA, except for supraspinatus tendon (SST) tears by both readers and for subscapularis tendon (SCT) tears by reader 2 in group B. 2D MRA and 3D isotropic sequences had high diagnostic performances for rotator and labral tears, and the difference between the two imaging methods was insignificant. Conclusions: The diagnostic performances of 3D isotropic VIBE and PD sequences were similar to those of 2D MRA

  17. Magnetic resonance imaging of the elbow. Part II: Abnormalities of the ligaments, tendons, and nerves

    Energy Technology Data Exchange (ETDEWEB)

    Kijowski, Richard; Tuite, Michael; Sanford, Matthew [University of Wisconsin Hospital, Department of Radiology, Madison, WI (United States)

    2005-01-01

    Part II of this comprehensive review on magnetic resonance imaging of the elbow discusses the role of magnetic resonance imaging in evaluating patients with abnormalities of the ligaments, tendons, and nerves of the elbow. Magnetic resonance imaging can yield high-quality multiplanar images which are useful in evaluating the soft tissue structures of the elbow. Magnetic resonance imaging can detect tears of the ulnar collateral ligament and lateral collateral ligament of the elbow with high sensitivity and specificity. Magnetic resonance imaging can determine the extent of tendon pathology in patients with medial epicondylitis and lateral epicondylitis. Magnetic resonance imaging can detect tears of the biceps tendon and triceps tendon and can distinguishing between partial and complete tendon rupture. Magnetic resonance imaging is also helpful in evaluating patients with nerve disorders at the elbow. (orig.)

  18. Gadolinium-enhanced magnetic resonance imaging in acute myocardial infarction

    International Nuclear Information System (INIS)

    Dijkman, P.R.M. van; Wall, E.E. van der; Roos, A. de; Doornbos, J.; Laarse, A. van der; Voorthuisen, A.E. van; Bruschke, A.V.G.; Rossum, A.C. van

    1990-01-01

    To evaluate he usefulness of the paramagnetic contrast agent Gadolinium-DTPA (diethylenetriaminepentaacetic acid) in Magnetic Resonance. Imaging of acute myocardial infarction, we studied a total of 45 patients with a first acute myocardial infarction by ECG-gated magnetic resonance imaging before and after intravenous administration of 0.1 mmol/kg Gadolinium-DTPA. All patients received thrombolytic treatment by intravenous streptokinase. The magnetic resonance imaging studies were preformed after a meam of 88 h (range 15-241) after the acute onset of acute myocardial infarction. Five patients without evidence of cardiac disease served as controls. Spin-echo measurements (TE 30 ms) were made using a Philips Gyroscan (0.5 Tesla) or a Teslacon II (0.6 Tesla). The 45 patients were divided into four groups of patients. In Group I( patients) Gadolinium-DTPA improved the detection of myocardial infarction by Gadolinium-DTPA. In Group II (20 patients) the magnetic resonance imaging procedure was repeated every 10 min for up to 40 min following administration of Gadolinium-DTPA. Optimal contrast enhancement was obtained 20-25 min after Gadolinium-DTPA. In Group III (27 patients) signal intensities were significantly higher in the patients who underwent the magnetic resonance imaging study more than 72 h (mean 120) after the acute event, suggesting increased acculumation of Gadolinium-DTPA in a more advanced stage of the infarction process. In Group IV (45 patients) Gadolinium-DTPA was administered in an attempt to distinguish between reperfused and nonreperfused myocardial areas after thrombolytic treatment for acute myocardial infarction. The signal intensities did not differ, but reperfused areas showed a more homogeneous aspect whereas nonreperfused areas were visualized as a more heterogeneous contrast enhancement. It is concluded that magnetic resonance imaging using the contrast agent Gadolinium-DTPA significantly improves the detection of infarcted myocardial areas

  19. Magnetic resonance imaging of popliteal artery pathologies

    International Nuclear Information System (INIS)

    Holden, Andrew; Merrilees, Stephen; Mitchell, Nicola; Hill, Andrew

    2008-01-01

    This paper illustrates examples of popliteal artery pathologies imaged with contrast enhanced magnetic resonance angiography (CE-MRA) and magnetic resonance imaging (MRI) at a single tertiary referral centre. Popliteal artery pathologies were identified in 1710 patients referred over a 6-year period with symptoms suggesting lower limb arterial occlusive disease. Common pathologies such as atherosclerotic occlusive disease, thromboemboli and aneurysm disease are discussed as well as unusual pathologies such as cystic adventitial disease, mycotic aneurysm and arterial entrapment. The combination of CE-MRA and the excellent soft tissue resolution of MRI allow detailed evaluation of arterial and peri-arterial pathologies, and facilitate appropriate management decisions

  20. Magnetic resonance imaging of popliteal artery pathologies

    Energy Technology Data Exchange (ETDEWEB)

    Holden, Andrew [Department of Radiology, Auckland City Hospital, Park Road, Grafton, Auckland 9 (New Zealand)], E-mail: andrewh@adhb.govt.nz; Merrilees, Stephen [Department of Radiology, Auckland City Hospital, Park Road, Grafton, Auckland 9 (New Zealand)], E-mail: smerrilees@adhb.govt.nz; Mitchell, Nicola [Department of Radiology, Auckland City Hospital, Park Road, Grafton, Auckland 9 (New Zealand)], E-mail: nmit010@ec.auckland.ac.nz; Hill, Andrew [Department of Vascular Surgery, Auckland City Hospital, Park Road, Grafton, Auckland 9 (New Zealand)], E-mail: ahill@adhb.govt.nz

    2008-07-15

    This paper illustrates examples of popliteal artery pathologies imaged with contrast enhanced magnetic resonance angiography (CE-MRA) and magnetic resonance imaging (MRI) at a single tertiary referral centre. Popliteal artery pathologies were identified in 1710 patients referred over a 6-year period with symptoms suggesting lower limb arterial occlusive disease. Common pathologies such as atherosclerotic occlusive disease, thromboemboli and aneurysm disease are discussed as well as unusual pathologies such as cystic adventitial disease, mycotic aneurysm and arterial entrapment. The combination of CE-MRA and the excellent soft tissue resolution of MRI allow detailed evaluation of arterial and peri-arterial pathologies, and facilitate appropriate management decisions.

  1. Vibration-synchronized magnetic resonance imaging for the detection of myocardial elasticity changes.

    Science.gov (United States)

    Elgeti, Thomas; Tzschätzsch, Heiko; Hirsch, Sebastian; Krefting, Dagmar; Klatt, Dieter; Niendorf, Thoralf; Braun, Jürgen; Sack, Ingolf

    2012-04-01

    Vibration synchronized magnetic resonance imaging of harmonically oscillating tissue interfaces is proposed for cardiac magnetic resonance elastography. The new approach exploits cardiac triggered cine imaging synchronized with extrinsic harmonic stimulation (f = 22.83 Hz) to display oscillatory tissue deformations in magnitude images. Oscillations are analyzed by intensity threshold-based image processing to track wave amplitude variations over the cardiac cycle. In agreement to literature data, results in 10 volunteers showed that endocardial wave amplitudes during systole (0.13 ± 0.07 mm) were significantly lower than during diastole (0.34 ± 0.14 mm, P magnetic resonance imaging improves the temporal resolution of magnetic resonance elastography as it overcomes the use of extra motion encoding gradients, is less sensitive to susceptibility artifacts, and does not suffer from dynamic range constraints frequently encountered in phase-based magnetic resonance elastography. Copyright © 2012 Wiley Periodicals, Inc.

  2. Magnetic resonance imaging in radiotherapy treatment planning

    NARCIS (Netherlands)

    Moerland, Marinus Adriaan

    1996-01-01

    From its inception in the early 1970's up to the present, magnetic resonance imaging (MRI) has evolved into a sophisticated technique, which has aroused considerable interest in var- ious subelds of medicine including radiotherapy. MRI is capable of imaging in any plane and does not use ionizing

  3. Caroli's disease: magnetic resonance imaging features

    Energy Technology Data Exchange (ETDEWEB)

    Guy, France; Cognet, Francois; Dranssart, Marie; Cercueil, Jean-Pierre; Conciatori, Laurent; Krause, Denis [Department of Radiology and Imaging, Dijon Le Bocage University Hospital, 2 Blvd. Marechal de Lattre de Tassigny, BP 1542, 21034 Dijon Cedex (France)

    2002-11-01

    Our objective was to describe the main aspects of MR imaging in Caroli's disease. Magnetic resonance cholangiography with a dynamic contrast-enhanced study was performed in nine patients with Caroli's disease. Bile duct abnormalities, lithiasis, dot signs, hepatic enhancement, renal abnormalities, and evidence of portal hypertension were evaluated. Three MR imaging patterns of Caroli's disease were found. In all but two patients, MR imaging findings were sufficient to confirm the diagnosis. Moreover, MR imaging provided information about the severity, location, and extent of liver involvement. This information was useful in planning the best therapeutic strategy. Magnetic resonance cholangiography with a dynamic contrast-enhanced study is a good screening tool for Caroli's disease. Direct cholangiography should be reserved for confirming doubtful cases. (orig.)

  4. Basic principles of magnetic resonance imaging - an update

    International Nuclear Information System (INIS)

    Scherzinger, A.L.; Hendee, W.R.

    1985-01-01

    Magnetic resonance (MR) imaging technology has undergone many technologic advances over the past few years. Many of these advances were stimulated by the wealth of information emerging from nuclear magnetic resonance research in the areas of new and optimal scanning methods and radio-frequency coil design. Other changes arose from the desire to improve image quality, ease siting restrictions and generally facilitate the clinical use of MR equipment. Many questions, however, remain unanswered. Perhaps the most controversial technologic question involves the optimal field strength required for imaging or spectroscopic applications or both. Other issues include safety and clinical efficacy. Technologic issues affect all aspects of MR use including the choice of equipment, examination procedure and image interpretation. Thus, an understanding of recent changes and their theoretic basis is necessary. 92 references, 10 figures, 1 table

  5. Application of magnetic resonance techniques for imaging tumour physiology

    International Nuclear Information System (INIS)

    Stubbs, M.

    1999-01-01

    Magnetic resonance (MR) techniques have the unique ability to measure in vivo the biochemical content of living tissue in the body in a dynamic, non-invasive and non-destructive manner. MR also permits serial investigations of steady-state tumour physiology and biochemistry, as well as the response of a tumour to treatment. Magnetic resonance imaging (MRI), Magnetic resonance spectroscopy (MRS) and a mixture of the two techniques (spectroscopic imaging) allow some physiological parameters, for example pH, to be 'imaged'. Using these methods, information on tissue bioenergetics and phospolipid membrane turnover, pH, hypoxia, oxygenation, and various aspects of vascularity including blood flow, angiogenesis, permeability and vascular volume can be obtained. In addition, MRS methods can be used for monitoring anticancer drugs (e.g. 5FU, ifosfamide) and their metabolites at their sites of action. The role of these state-of-the-art MR methods in imaging tumour physiology and their potential role in the clinic are discussed. (orig.)

  6. Impact of magnetic resonance imaging on preoperative planning for breast cancer surgery.

    Science.gov (United States)

    Law, Y; Cheung, Polly S Y; Lau, Silvia; Lo, Gladys G

    2013-08-01

    To review the impact of preoperative breast magnetic resonance imaging on the management of planned surgery, and the appropriateness of any resulting alterations. Retrospective review. A private hospital in Hong Kong. PATIENTS; For the 147 consecutive biopsy-proven breast cancer patients who underwent preoperative magnetic resonance imaging to determine tumour extent undergoing operation by a single surgeon between 1 January 2006 and 31 December 2009, the impact of magnetic resonance imaging findings was reviewed in terms of management alterations and their appropriateness. The most common indication for breast magnetic resonance imaging was the presence of multiple indeterminate shadows on ultrasound scans (53%), followed by ill-defined border of the main tumour on ultrasound scans (19%). In 66% (97 out of 147) of the patients, the extent of the operation was upgraded. Upgrading entailed: lumpectomy to wider lumpectomy (23 out of 97), lumpectomy to mastectomy (47 out of 97), lumpectomy to bilateral lumpectomy (15 out of 97), and other (12 out of 97). Mostly, these management changes were because magnetic resonance imaging showed more extensive disease (n=29), additional cancer foci (n=39), or contralateral disease (n=24). In five instances, upgrading was due to patient preference. In 34% (50 out of 147) of the patients, there was no change in the planned operation. Regarding 97 of the patients having altered management, in 12 the changes were considered inappropriately extensive (due to false-positive magnetic resonance imaging findings). In terms of magnetic resonance imaging detection of more extensive, multifocal, multicentric, or contralateral disease, the false-positive rate was 13% and false-negative rate 7%. Corresponding rates for sensitivity and specificity were 95% and 81%, using the final pathology as the gold standard. Preoperative magnetic resonance imaging had a clinically significant and mostly correct impact on management plans. Magnetic resonance

  7. Basic principles of nuclear magnetic resonance imaging

    International Nuclear Information System (INIS)

    Valk, J.; MacLean, C.; Algra, P.R.

    1985-01-01

    The intent of this book is to help clinicians understand the basic physical principles of magnetic resonance (MR) imaging. The book consists of the following: a discussion of elementary considerations; pulse sequencing; localization of MR signals in space; MR equipment; MR contrast agents; clinical applications; MR spectroscopy; and biological effects of MR imaging; a set of appendixes; and a bibliography. Illustrations and images are included

  8. Finding the Truth in Medical Imaging: Painting the Picture of Appropriateness for Magnetic Resonance Imaging in Canada.

    Science.gov (United States)

    Vanderby, Sonia; Peña-Sánchez, Juan Nicolás; Kalra, Neil; Babyn, Paul

    2015-11-01

    Questions about the appropriateness of medical imaging exams, particularly related to magnetic resonance exams, have arisen in recent years. However, the prevalence of inappropriate imaging in Canada is unclear as inappropriate exam proportion estimates are often based on studies from other countries. Hence, we sought to compare and summarize Canadian studies related to magnetic resonance imaging appropriateness. We completed a systematic literature search identifying studies related to magnetic resonance appropriateness in Canada published between 2003 and 2013. Two researchers independently searched and evaluated the literature available. Articles that studied or discussed magnetic resonance appropriateness in Canada were selected based on titles, abstracts, and, where necessary, full article review. Articles relating solely to other modalities or countries were excluded, as were imaging appropriateness guidelines and reviews. Fourteen articles were included: 8 quantitative studies and 6 editorials/commentaries. The quantitative studies reported inappropriate proportions of magnetic resonance exams ranging from 2%-28.5%. Our review also revealed substantial variations among study methods and analyses. Common topics identified among editorials/commentaries included reasons for obtaining imaging in general and for selecting a specific modality, consequences of inappropriate imaging, factors contributing to demand, and suggested means of mitigating inappropriate medical imaging use. The available studies do not support the common claim that 30% of medical imaging exams in Canada are inappropriate. The actual proportion of inappropriate magnetic resonance exams has not yet been established conclusively in Canada. Further research, particularly on a widespread national scale, is needed to guide healthcare policies. Copyright © 2015 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  9. Magnetic resonance imaging of Parkinsonism

    International Nuclear Information System (INIS)

    Mukai, Eiichiro; Makino, Naoki; Fujishiro, Kenichiro.

    1989-01-01

    We have analyzed magnetic resonance images in 33 patients; 18 patients with Parkinson's disease, 1 patient with diurnally fluctuating progressive dystonia, 1 patient with pure akinesia, 6 patients with multiple system atrophy, 1 patient with flunarizine induced parkinsonism, and 4 patients with unclassified parkinsonism. The MR images were obtained using a 1.5-T GE MR System. A spin-echo pulse sequence was used with a TE of 30 msec and 80 msec and a TR of 2000 msec. No signal abnormalities were seen in any patient with Parkinson's disease but 3 showed slightly decreased signal intensity of the putamen on T2-weighted sequences. Patients with diurnally fluctuating progressive dystonia and pure akinesia evidensed no abnormal findings. All six patients with multiple system atrophy demonstrated decreased signal intensity of the putamen, particularly along their lateral and posterior portions, and an enlarged substantia nigra. Atrophy of the pons and cerebellum was detected in all cases with multiple system atrophy. One case of flunarizine induced parkinsonism showed slightly decreased signal intensity of the putamen. Four cases of unclassified parkinsonism showed decreased signal in the putamen on T2-weighted sequences. Magnetic resonance imaging has the potential to become a useful diagnostic tool in the management of parkinsonism. (author)

  10. Magnetic resonance imaging of Parkinsonism

    Energy Technology Data Exchange (ETDEWEB)

    Mukai, Eiichiro [National Hospital of Nagoya (Japan); Makino, Naoki; Fujishiro, Kenichiro

    1989-06-01

    We have analyzed magnetic resonance images in 33 patients; 18 patients with Parkinson's disease, 1 patient with diurnally fluctuating progressive dystonia, 1 patient with pure akinesia, 6 patients with multiple system atrophy, 1 patient with flunarizine induced parkinsonism, and 4 patients with unclassified parkinsonism. The MR images were obtained using a 1.5-T GE MR System. A spin-echo pulse sequence was used with a TE of 30 msec and 80 msec and a TR of 2000 msec. No signal abnormalities were seen in any patient with Parkinson's disease but 3 showed slightly decreased signal intensity of the putamen on T2-weighted sequences. Patients with diurnally fluctuating progressive dystonia and pure akinesia evidensed no abnormal findings. All six patients with multiple system atrophy demonstrated decreased signal intensity of the putamen, particularly along their lateral and posterior portions, and an enlarged substantia nigra. Atrophy of the pons and cerebellum was detected in all cases with multiple system atrophy. One case of flunarizine induced parkinsonism showed slightly decreased signal intensity of the putamen. Four cases of unclassified parkinsonism showed decreased signal in the putamen on T2-weighted sequences. Magnetic resonance imaging has the potential to become a useful diagnostic tool in the management of parkinsonism. (author).

  11. Current role of multidetector computed tomography in imaging of wrist injuries.

    Science.gov (United States)

    Syed, Mohd Arif; Raj, Vimal; Jeyapalan, Kanagaratnam

    2013-01-01

    Imaging of the wrist is challenging to both radiologists and orthopedic surgeons. This is primarily because of the complex anatomy/functionality of the wrist and also the fact that many frequent injuries are sustained to the hands. On going developments in multidetector computed tomography (MDCT) technology with its "state of the art" postprocessing capabilities have revolutionized this field. Apart from routine imaging of wrist trauma, it is now possible to assess intrinsic ligaments with MDCT arthrography, thereby avoiding invasive diagnostic arthroscopies. Postoperative wrist imaging can be a diagnostic challenge, and MDCT can be helpful in assessment of these cases because volume acquisition and excellent postprocessing abilities help to evaluate these wrists in any desired plane and thinner slices. This article pictorially reviews the current clinical role of MDCT imaging of wrist in our practice. It also describes arthrography technique and scanning parameters used at our center. Copyright © 2013 Mosby, Inc. All rights reserved.

  12. Magnetic resonance imaging of aneurysmal subarachnoid hemorrhage

    International Nuclear Information System (INIS)

    Ogawa, Toshihide; Shimosegawa, Eku; Inugami, Atsushi; Shishido, Fumio; Fujita, Hideaki; Ito, Hiroshi; Uemura, Kazuo; Yasui, Nobuyuki

    1991-01-01

    Magnetic resonance imaging of subarachnoid hemorrhage (SAH) due to aneurysm rupture was evaluated in relation to CT findings in nine patients. Six patients were studied within 3 days and the other three patients were studied 4 to 6 days from the ictus of SAH using a 0.5 Tesla superconducting unit. In all of the patients, hematoma in the subarachnoid space and ventricles was demonstrated by the proton density-weighted spin echo sequence, which showed that bloody cerebrospinal fluid (CSF) had a higher signal intensity than brain tissue or normal CSF. Magnetic resonance imaging was more sensitive in detecting SAH and more informative as to the site of the ruptured aneurysm than CT. Despite some limitations in applying it to patients with acute SAH, magnetic resonace imaging has clear advantages in the diagnosis of SAH. (author)

  13. Magnetic resonance imaging of aneurysmal subarachnoid hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Ogawa, Toshihide; Shimosegawa, Eku; Inugami, Atsushi; Shishido, Fumio; Fujita, Hideaki; Ito, Hiroshi; Uemura, Kazuo; Yasui, Nobuyuki (Research Inst. of Brain and Blood Vessels, Akita (Japan))

    1991-11-01

    Magnetic resonance imaging of subarachnoid hemorrhage (SAH) due to aneurysm rupture was evaluated in relation to CT findings in nine patients. Six patients were studied within 3 days and the other three patients were studied 4 to 6 days from the ictus of SAH using a 0.5 Tesla superconducting unit. In all of the patients, hematoma in the subarachnoid space and ventricles was demonstrated by the proton density-weighted spin echo sequence, which showed that bloody cerebrospinal fluid (CSF) had a higher signal intensity than brain tissue or normal CSF. Magnetic resonance imaging was more sensitive in detecting SAH and more informative as to the site of the ruptured aneurysm than CT. Despite some limitations in applying it to patients with acute SAH, magnetic resonace imaging has clear advantages in the diagnosis of SAH. (author).

  14. Multi-detector CT knee arthrography - initial experience

    International Nuclear Information System (INIS)

    Thomson, J.M.Z.; Fallon, M.; Breidahl, W.H.

    2002-01-01

    Full text: Traditional plain film arthrography can achieve reasonable accuracy and is an accepted method of investigation of patients with knee pain and possible meniscal tear. Multi-detector CT can potentially provide a more detailed and accurate examination due to its high-resolution crosssectional and multi-planar capabilities. The aim of this study was to assess the accuracy of our technique. All patients who underwent a multi-detector CT knee arthrogram in an initial 8 month period were identified. Initially the referring clinician was contacted. If the patient was referred to an orthopaedic surgeon the outcome of orthopaedic review was recorded using clinical, arthroscopic and / or MRI follow-up of the patient population. One hundred and twelve patients had a Multi-detector CT knee arthrogram performed within and 8 month period. Follow-up information was received in 69.7% of patients. Of these 68.9% had orthopaedic assessment - of which 69.2% underwent a knee arthroscopy.There was total agreement of findings in 67%, agreement of meniscal findings in 67% and chondral findings in 100%. Overall, orthopaedic opinion agreed with CT findings in 76.9%. At this stage, all meniscal tears not described in the initial CT arthrogram report have in retrospect been visible. Multi-detector CT knee arthrography is an accurate and elegant technique for investigation of knee pain, providing information in a format familiar to those reporting knee MRI. There is an initial learning curve. The technique is particularly useful in chondral assessment. It is accurate for meniscal pathology, although caution and recognition of potential pitfalls is required. Copyright (2002) Blackwell Science Pty Ltd

  15. Magnetic resonance imaging in central nervous system tuberculosis

    International Nuclear Information System (INIS)

    Trivedi, Richa; Saksena, Sona; Gupta, Rakesh K

    2009-01-01

    Tuberculosis (TB) in any form is a devastating disease, which in its most severe form involves the central nervous system (CNS), with a high mortality and morbidity. Early diagnosis of CNS TB is necessary for appropriate treatment to reduce this morbidity and mortality. Routine diagnostic techniques involve culture and immunological tests of the tissue and biofluids, which are time-consuming and may delay definitive management. Noninvasive imaging modalities such as computed tomography (CT) scan and magnetic resonance imaging (MRI) are routinely used in the diagnosis of neurotuberculosis, with MRI offering greater inherent sensitivity and specificity than CT scan. In addition to conventional MRI imaging, magnetization transfer imaging, diffusion imaging, and proton magnetic resonance spectroscopy techniques are also being evaluated for better tissue characterization in CNS TB. The current article reviews the role of various MRI techniques in the diagnosis and management of CNS TB

  16. Accuracy of double-contrast arthrography and arthroscopy of the knee joint

    International Nuclear Information System (INIS)

    Thijn, C.J.P.

    1982-01-01

    Only in the diagnosis of medial meniscal lesions is double contrast arthrography superior to arthroscopy, provided that arthroscopy is carried out only from the anterolateral side (94% against 81% positive correlations). The rates in diagnosing lateral meniscal lesions are respectively 90% and 94.5%, in patellar chondropathy 55% and 99.5% respectively, and in diagnosting cruciate ligament lesions 69% and 97% respectively

  17. Accuracy of double-contrast arthrography and arthroscopy of the knee joint

    International Nuclear Information System (INIS)

    Thijn, C.J.P.

    1982-01-01

    Only in the diagnosis of medial meniscal lesions is double contrast arthrography superior to arthroscopy, provided that arthroscopy is carried out only from the anterolateral side (94% against 81% positive correlations). The rates in diagnosing lateral meniscal lesions are respectively 90% and 94.5%, in patellar chondropathy 55% and 99.5% respectively, and in diagnosting cruciate ligament lesions 69% and 97% respectively. (orig.)

  18. Quantitative perfusion imaging in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Zoellner, F.G.; Gaa, T.; Zimmer, F.; Ong, M.M.; Riffel, P.; Hausmann, D.; Schoenberg, S.O.; Weis, M.

    2016-01-01

    Magnetic resonance imaging (MRI) is recognized for its superior tissue contrast while being non-invasive and free of ionizing radiation. Due to the development of new scanner hardware and fast imaging techniques during the last decades, access to tissue and organ functions became possible. One of these functional imaging techniques is perfusion imaging with which tissue perfusion and capillary permeability can be determined from dynamic imaging data. Perfusion imaging by MRI can be performed by two approaches, arterial spin labeling (ASL) and dynamic contrast-enhanced (DCE) MRI. While the first method uses magnetically labelled water protons in arterial blood as an endogenous tracer, the latter involves the injection of a contrast agent, usually gadolinium (Gd), as a tracer for calculating hemodynamic parameters. Studies have demonstrated the potential of perfusion MRI for diagnostics and also for therapy monitoring. The utilization and application of perfusion MRI are still restricted to specialized centers, such as university hospitals. A broad application of the technique has not yet been implemented. The MRI perfusion technique is a valuable tool that might come broadly available after implementation of standards on European and international levels. Such efforts are being promoted by the respective professional bodies. (orig.) [de

  19. Magnetic nanoparticles in magnetic resonance imaging and diagnostics.

    Science.gov (United States)

    Rümenapp, Christine; Gleich, Bernhard; Haase, Axel

    2012-05-01

    Magnetic nanoparticles are useful as contrast agents for magnetic resonance imaging (MRI). Paramagnetic contrast agents have been used for a long time, but more recently superparamagnetic iron oxide nanoparticles (SPIOs) have been discovered to influence MRI contrast as well. In contrast to paramagnetic contrast agents, SPIOs can be functionalized and size-tailored in order to adapt to various kinds of soft tissues. Although both types of contrast agents have a inducible magnetization, their mechanisms of influence on spin-spin and spin-lattice relaxation of protons are different. A special emphasis on the basic magnetism of nanoparticles and their structures as well as on the principle of nuclear magnetic resonance is made. Examples of different contrast-enhanced magnetic resonance images are given. The potential use of magnetic nanoparticles as diagnostic tracers is explored. Additionally, SPIOs can be used in diagnostic magnetic resonance, since the spin relaxation time of water protons differs, whether magnetic nanoparticles are bound to a target or not.

  20. Low field magnetic resonance imaging

    Science.gov (United States)

    Pines, Alexander; Sakellariou, Dimitrios; Meriles, Carlos A.; Trabesinger, Andreas H.

    2010-07-13

    A method and system of magnetic resonance imaging does not need a large homogenous field to truncate a gradient field. Spatial information is encoded into the spin magnetization by allowing the magnetization to evolve in a non-truncated gradient field and inducing a set of 180 degree rotations prior to signal acquisition.

  1. Nitroxide radicals as contrast substances for magnetic resonance imaging diagnostics. Part 1

    International Nuclear Information System (INIS)

    Zhelev, Z.

    2016-01-01

    In last ten years, there is a significant progress in the selective and localized detection of redox-active compounds in the cells, tissues, and intact organisms. This progress is due to the development of new synthetic and genetically encoded redox-sensitive contrast substances, as well as due to the improvement of the techniques for their imaging: fluorescent, chemiluminescent, magnetic resonance, nuclear, ultrasonic. One of the most attractive redox-sensitive contrast substances are cyclic (stable) nitroxide radicals. They can be visualized and analyzed in vitro and in vivo by a variety of magnetic resonance techniques - electron-paramagnetic resonance imaging (EPRI), magnetic resonance imaging (MRI), Overhauser-enhanced MRI (OMRI). This review describes the merits and demerits of the nitroxide-enhanced EPR and MRI and the perspectives for their application in biomedical studies and clinical practice. The article is intended for a wide range of readers - from students to specialists in the field. Key words: Magnetic Resonance Imaging (MRI). Electron-Paramagnetic Resonance (EPR). Overhauser-Enhanced MRI (O MRI). Nitroxide

  2. Image potential resonances of the aluminum (100) surface; Bildpotentialresonanzen der Aluminium-(100)-Oberflaeche

    Energy Technology Data Exchange (ETDEWEB)

    Winter, Matthias

    2011-07-08

    Image-potential resonances on the (100) surface of pure Aluminum are investigated experimentally and theoretically. The experiments are conducted both energy- and time-resolved using the method of two-photon photoemission spectroscopy. The main attention of the theoretical examination and extensive numerical calculations is devoted to the interaction between surface and bulk states. Image-potential resonances on Al(100) are a system in which a complete series of discrete Rydberg states strongly couples to a continuum of states. As a simple metal it also provides a good opportunity to test theoretical models of the structure of the potential at metal surfaces. This work represents the first high-resolution investigation of image-potential resonances with such strong resonance character. For the first time, it is demonstrated experimentally that isolated image-potential resonances exist on an Aluminum surface. On the (100) surface of Aluminum the second through fifth image-potential resonance are resolved and both, their energies and lifetimes are measured. The binding energies of the image-potential resonances form a Rydberg series of states {epsilon}{sub n}=-(0,85 eV)/((n+a){sup 2}). Within the accuracy of the measurement it is not necessary to introduce a quantum defect a (a=0.022{+-}0.035). Using angle-resolved two-photon photoemission spectroscopy the effective mass of electrons in the second image-potential resonance is measured to 1.01{+-}0.11 electron masses. The lifetimes of the resonances increase as {tau}{sub n} = (1.0{+-}0.2)fs.n{sup 3} starting from n=2. Calculations using the density matrix formalism show that the experimentally observed lifetimes can be explained well by electrons decaying into the bulk. The effect of resonance trapping leads to extended lifetimes in the process. Contrary to common theoretical models of image-potential states at metal surfaces the first image-potential resonance cannot be observed in two-photon photoemission on Al(100

  3. 3-T direct MR arthrography of the wrist: Value of finger trap distraction to assess intrinsic ligament and triangular fibrocartilage complex tears

    Energy Technology Data Exchange (ETDEWEB)

    Cerny, Milena; Marlois, Romain [Department of Diagnostic and Interventional Radiology, Centre Hospitalier Universitaire Vaudois, University of Lausanne, Rue du Bugnon 46, 1011 Lausanne (Switzerland); Theumann, Nicolas [Institute of Radiology, Clinique Hirslanden Bois-Cerf, Avenue d’Ouchy 31, 1006 Lausanne (Switzerland); Bollmann, Christof; Wehrli, Laurent [Department of Plastic and Hand Surgery, Clinique Longeraie and Centre Hospitalier Universitaire Vaudois, University of Lausanne, Avenue de la Gare 9, 1003 Lausanne (Switzerland); Richarme, Delphine [Institute of Radiology, Clinique Hirslanden Bois-Cerf, Avenue d’Ouchy 31, 1006 Lausanne (Switzerland); Meuli, Reto [Department of Diagnostic and Interventional Radiology, Centre Hospitalier Universitaire Vaudois, University of Lausanne, Rue du Bugnon 46, 1011 Lausanne (Switzerland); Becce, Fabio, E-mail: fabio.becce@chuv.ch [Department of Diagnostic and Interventional Radiology, Centre Hospitalier Universitaire Vaudois, University of Lausanne, Rue du Bugnon 46, 1011 Lausanne (Switzerland)

    2013-10-01

    Purpose: To determine the value of applying finger trap distraction during direct MR arthrography of the wrist to assess intrinsic ligament and triangular fibrocartilage complex (TFCC) tears. Materials and methods: Twenty consecutive patients were prospectively investigated by three-compartment wrist MR arthrography. Imaging was performed with 3-T scanners using a three-dimensional isotropic (0.4 mm) T1-weighted gradient-recalled echo sequence, with and without finger trap distraction (4 kg). In a blind and independent fashion, two musculoskeletal radiologists measured the width of the scapholunate (SL), lunotriquetral (LT) and ulna-TFC (UTFC) joint spaces. They evaluated the amount of contrast medium within these spaces using a four-point scale, and assessed SL, LT and TFCC tears, as well as the disruption of Gilula's carpal arcs. Results: With finger trap distraction, both readers found a significant increase in width of the SL space (mean Δ = +0.1 mm, p ≤ 0.040), and noticed more contrast medium therein (p ≤ 0.035). In contrast, the differences in width of the LT (mean Δ = +0.1 mm, p ≥ 0.057) and UTFC (mean Δ = 0 mm, p ≥ 0.728) spaces, as well as the amount of contrast material within these spaces were not statistically significant (p = 0.607 and ≥0.157, respectively). Both readers detected more SL (Δ = +1, p = 0.157) and LT (Δ = +2, p = 0.223) tears, although statistical significance was not reached, and Gilula's carpal arcs were more frequently disrupted during finger trap distraction (Δ = +5, p = 0.025). Conclusion: The application of finger trap distraction during direct wrist MR arthrography may enhance both detection and characterisation of SL and LT ligament tears by widening the SL space and increasing the amount of contrast within the SL and LT joint spaces.

  4. 3-T direct MR arthrography of the wrist: value of finger trap distraction to assess intrinsic ligament and triangular fibrocartilage complex tears.

    Science.gov (United States)

    Cerny, Milena; Marlois, Romain; Theumann, Nicolas; Bollmann, Christof; Wehrli, Laurent; Richarme, Delphine; Meuli, Reto; Becce, Fabio

    2013-10-01

    To determine the value of applying finger trap distraction during direct MR arthrography of the wrist to assess intrinsic ligament and triangular fibrocartilage complex (TFCC) tears. Twenty consecutive patients were prospectively investigated by three-compartment wrist MR arthrography. Imaging was performed with 3-T scanners using a three-dimensional isotropic (0.4 mm) T1-weighted gradient-recalled echo sequence, with and without finger trap distraction (4 kg). In a blind and independent fashion, two musculoskeletal radiologists measured the width of the scapholunate (SL), lunotriquetral (LT) and ulna-TFC (UTFC) joint spaces. They evaluated the amount of contrast medium within these spaces using a four-point scale, and assessed SL, LT and TFCC tears, as well as the disruption of Gilula's carpal arcs. With finger trap distraction, both readers found a significant increase in width of the SL space (mean Δ = +0.1mm, p ≤ 0.040), and noticed more contrast medium therein (p ≤ 0.035). In contrast, the differences in width of the LT (mean Δ = +0.1 mm, p ≥ 0.057) and UTFC (mean Δ = 0mm, p ≥ 0.728) spaces, as well as the amount of contrast material within these spaces were not statistically significant (p = 0.607 and ≥ 0.157, respectively). Both readers detected more SL (Δ = +1, p = 0.157) and LT (Δ = +2, p = 0.223) tears, although statistical significance was not reached, and Gilula's carpal arcs were more frequently disrupted during finger trap distraction (Δ = +5, p = 0.025). The application of finger trap distraction during direct wrist MR arthrography may enhance both detection and characterisation of SL and LT ligament tears by widening the SL space and increasing the amount of contrast within the SL and LT joint spaces. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  5. Radiography, radionuclide imaging, and asthrography in the evaluation of total hip and knee replacement. [/sup 99m/Tc-phosphate

    Energy Technology Data Exchange (ETDEWEB)

    Gelman, M.I.; Coleman, R.E.; Stevens, P.M.; Davey, B.W.

    1978-09-01

    Twenty patients with 21 total joint replacements including 17 hips and 4 knees were studied by plain film radiography, radionuclide imaging, and subtraction arthrography to evaluate these procedures for assessing prosthetic complications. Surgery was performed in 14 patients and confirmed loosening of 8 femoral and 7 acetabular hip prosthesis components and 1 femoral and 4 tibial knee prosthesis components. Plain films suggested loosening of only 9 hip components and no knee components. In contrast, radionuclide imaging and subtraction arthrography were considerably more effective in demonstrating loosening as well as other causes of the painful total joint prosthesis.

  6. Magnetic resonance imaging- physical principles and clinical application

    International Nuclear Information System (INIS)

    Tavri, O.J.

    1996-01-01

    The advances in imaging techniques for better and efficient diagnosis have become possible with the advent of Magnetic Resonance Imaging (MRI). The modalities of MRI technique for indication and diagnosis are mentioned in with typical examples. (author)

  7. Epidural fat image in lumbar magnetic resonance image

    International Nuclear Information System (INIS)

    Nishijima, Yuichiro; Yamasaki, Yasuo; Higashida, Norihiko; Okada, Masato

    1993-01-01

    To examine epidural fat images, lumbar magnetic resonance (MR) images were retrospectively reviewed in a total of 103 patients with surgically proven lumbar disc herniation (DH, n=57) and lumbar canal stenosis (LCS, n=46). Epidural fat images consisted of middorsal epidural fat (MDF), paramedian ventral fat (PVF) and intervertebral foraminal fat (IFF) ones. In the group of DH, the thickness of MDF image did not correlate with that of subcutaneous fat, suggesting that epidural fat was not affected by body fat. From the pathophysiological point of view, decrease and disappearance of MDF images correlated with compression of the epidural canal. Decrease and disappearance of PVF images lead to suspicious compression of the traversing root. In addition, asymmetrical PVF images were useful for the bilateral diagnosis of herniation. Abnormal findings of IFF images were suggestive of compression of the exiting nerve root at the intervertebral foramen. This was also seen frequently at the non-responsible level in patients over the age of 50. Degenerative and sequentrated spondylolistheses in the group of LCS were more frequently associated with a higher incidence of abnormal findings of IFF images, suggesting the presence of existing nerve root compression. (N.K.)

  8. Bony vibration stimulation test combined with magnetic resonance imaging. Can discography be replaced?

    Science.gov (United States)

    Yrjämä, M; Tervonen, O; Kurunlahti, M; Vanharanta, H

    1997-04-01

    The results of two noninvasive methods, magnetic resonance imaging and a bony vibration test, were compared with discographic pain provocation findings. To evaluate whether the combination of magnetic resonance imaging and vibration pain provocation tests could be used to replace discography in low back pain diagnostics. Magnetic resonance imaging gives a wealth of visual information on anatomic changes of the spine with often unknown clinical significance. Discographic examination of the spine is still the only widely accepted diagnostic method that can relate the pathoanatomic changes to the patient's clinical pain. Internal anular rupture has been shown to be one of the sources of back pain. The bony vibration test of the spinal processes has been shown correlate well with discographic pain provocation tests in cases of internal anular rupture. The three lowest lumbar discs of 33 patients with back pain were examined by means of magnetic resonance imaging and a bony vibration stimulation test, and the results were compared with those from computed tomography-discography. In cases of intradiscal magnetic resonance imaging findings, the vibration provocation test showed a sensitivity of 0.88 and a specificity of 0.50 compared with the discographic pain provocation test. If the patients with previous back surgery were excluded, the specificity was 0.75. In the cases of total anular rupture, the sensitivity was 0.50, and the specificity was 0.33. The combination of the two noninvasive methods, vibration stimulation and magnetic resonance imaging, gives more information on the origin of the back pain than magnetic resonance imaging alone. The pathoanatomic changes seen in magnetic resonance imaging can be correlated with the patient's disorder more reliably using the vibration provocation test in the cases of partial anular ruptures. The use of discography can be limited mostly to cases with total anular ruptures detected by magnetic resonance imaging.

  9. Sensorineural hearing loss after magnetic resonance imaging

    DEFF Research Database (Denmark)

    Mollasadeghi, Abolfazl; Mehrparvar, Amir Houshang; Atighechi, Saeid

    2013-01-01

    Magnetic resonance imaging (MRI) devices produce noise, which may affect patient's or operators' hearing. Some cases of hearing impairment after MRI procedure have been reported with different patterns (temporary or permanent, unilateral or bilateral, with or without other symptoms like tinnitus)......). In this report, a case of bilateral sensorineural hearing loss in an otherwise healthy patient underwent brain MRI was described. The patient's hearing loss was accompanied with tinnitus and was not improved after 3 months of followup.......Magnetic resonance imaging (MRI) devices produce noise, which may affect patient's or operators' hearing. Some cases of hearing impairment after MRI procedure have been reported with different patterns (temporary or permanent, unilateral or bilateral, with or without other symptoms like tinnitus...

  10. A comparison of arthrography to clinical diagnostics for diagnosing meniscal lesions

    International Nuclear Information System (INIS)

    Neuer, H.

    1982-01-01

    A comparative investigation as to the exactness of clinical and arthrographical diagnostics was carried out on 176 patients who were clinically examined and operated on in the period of 1972-1980. Using solely clinical diagnostics, the total rate of exactness was 90,9%, the exactness regarding the internal meniscal lesion being significantly higher (94.2%) than that regarding external meniscal lesion (76.7%). Using solely arthrographic diagnostics, the total rate of exactness was 82%, the rate for internal meniscus being significantly lower (83.9%) than that obtained using clinical diagnostics. As for the external meniscus, the exactness of arthrography differs only slightly from clinical diagnostics with 74.7%. The most frequent sources of error in arthorgraphy were found to be lesions of the posterior horn at the internal meniscus. In cases of external meniscal lesions, especially when an internal meniscal lesion was existing at the same time, both examination methods failed in 5 cases. For routine diagnosing of meniscal lesions, arthrography is not necessary. An accurate clinical examination and anamnesis bring very good and exact results and should therefore be given absolute priority. (orig./MG) [de

  11. Artifacts Affecting Musculoskeletal Magnetic Resonance Imaging: Their Origins and Solutions.

    Science.gov (United States)

    Roth, Eira; Hoff, Michael; Richardson, Michael L; Ha, Alice S; Porrino, Jack

    2016-01-01

    Among articles within the radiology literature, few present the manifestations of magnetic resonance imaging artifacts in a clinically oriented manner. Recognizing such artifacts is imperative given the increasing clinical use of magnetic resonance imaging and the emphasis by the American Board of Radiology on practical physics applications. The purpose of this article is to present magnetic resonance physics principles visually and conceptually in the context of common musculoskeletal radiology artifacts and their solutions, described using nonmathematical explanations. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Development of the 1.2 T~1.5 T Permanent Magnetic Resonance Imaging Device and Its Application for Mouse Imaging

    Directory of Open Access Journals (Sweden)

    Guangxin Wang

    2015-01-01

    Full Text Available By improving the main magnet, gradient, and RF coils design technology, manufacturing methods, and inventing new magnetic resonance imaging (MRI special alloy, a cost-effective and small animal specific permanent magnet-type three-dimensional magnetic resonance imager was developed. The main magnetic field strength of magnetic resonance imager with independent intellectual property rights is 1.2~1.5 T. To demonstrate its effectiveness and validate the mouse imaging experiments in different directions, we compared the images obtained by small animal specific permanent magnet-type three-dimensional magnetic resonance imager with that obtained by using superconductor magnetic resonance imager for clinical diagnosis.

  13. Neurilemmoma of the glans penis: ultrasonography and magnetic resonance imaging findings.

    Science.gov (United States)

    Jung, Dae Chul; Hwang, Sung Il; Jung, Sung Il; Kim, Sun Ho; Kim, Seung Hyup

    2006-01-01

    Neurilemmoma of the glans penis is rare, and no imaging findings have been reported. A case of neurilemmoma of the glans penis is presented. Ultrasonography (US) and magnetic resonance imaging revealed a well-defined small mass in the glans penis. The mass appeared hypoechoic on gray-scale US and hypervascular on color Doppler US. Magnetic resonance imaging revealed high signal intensity of the mass on a T2-weighted image and strong enhancement on a contrast-enhanced T1-weighted image.

  14. Contemporary imaging: Magnetic resonance imaging, computed tomography, and interventional radiology

    International Nuclear Information System (INIS)

    Goldberg, H.I.; Higgins, C.; Ring, E.J.

    1985-01-01

    In addition to discussing the most recent advances in magnetic resonance imaging (MRI), computerized tomography (CT), and the vast array of interventional procedures, this book explores the appropriate clinical applications of each of these important modalities

  15. Magnetic resonance imaging-compatible tactile sensing device based on a piezoelectric array.

    Science.gov (United States)

    Hamed, Abbi; Masamune, Ken; Tse, Zion Tsz Ho; Lamperth, Michael; Dohi, Takeyoshi

    2012-07-01

    Minimally invasive surgery is a widely used medical technique, one of the drawbacks of which is the loss of direct sense of touch during the operation. Palpation is the use of fingertips to explore and make fast assessments of tissue morphology. Although technologies are developed to equip minimally invasive surgery tools with haptic feedback capabilities, the majority focus on tissue stiffness profiling and tool-tissue interaction force measurement. For greatly increased diagnostic capability, a magnetic resonance imaging-compatible tactile sensor design is proposed, which allows minimally invasive surgery to be performed under image guidance, combining the strong capability of magnetic resonance imaging soft tissue and intuitive palpation. The sensing unit is based on a piezoelectric sensor methodology, which conforms to the stringent mechanical and electrical design requirements imposed by the magnetic resonance environment The sensor mechanical design and the device integration to a 0.2 Tesla open magnetic resonance imaging scanner are described, together with the device's magnetic resonance compatibility testing. Its design limitations and potential future improvements are also discussed. A tactile sensing unit based on a piezoelectric sensor principle is proposed, which is designed for magnetic resonance imaging guided interventions.

  16. Imaging findings of spontaneous detachment of the deltoid muscle as a complication of massive rotator cuff tear

    International Nuclear Information System (INIS)

    Bianchi, Stefano; Martinoli, Carlo; Abdelwahab, Ibrahim Fikry

    2006-01-01

    A tear at the origin of the deltoid muscle is uncommon and usually occurs as a complication of shoulder surgery. We report a case of spontaneous deltoid detachment as a complication of massive rotator cuff tear in a 70-year-old woman evaluated by standard radiographs, ultrasound, arthrography and MR-arthrography. We present the multimodality imaging findings with review of the literature. We found that ultrasound is an accurate modality in detecting and assessing spontaneous detachment of the deltoid muscle. As ultrasound is a noninvasive, low-cost, and universally available imaging modality we suggest using ultrasound as the first modality for evaluation of spontaneous detachment of the deltoid muscle. (orig.)

  17. Proton magnetic resonance spectroscopy and perfusion magnetic resonance imaging in the evaluation of musculoskeletal tumors

    International Nuclear Information System (INIS)

    Costa, Flavia Martins; Setti, Marcela; Vianna, Evandro Miguelote; Domingues, Romulo Cortes; Meohas, Walter; Rezende, Jose Francisco; Gasparetto, Emerson Leandro

    2009-01-01

    Objective: To assess the role of proton magnetic resonance spectroscopy and dynamic contrast-enhanced magnetic resonance imaging in the differentiation between malignant and benign musculoskeletal tumors. Materials And Methods: Fifty-five patients with musculoskeletal tumors (27 malignant and 28 benign) were studied. The examinations were performed in a 1.5 T magnetic resonance scanner with standard protocol, and single voxel proton magnetic resonance spectroscopy with 135 msec echo time. The dynamic contrast study was performed using T1-weighted gradient-echo sequence after intravenous gadolinium injection. Time signal intensity curves and slope values were calculated. The statistical analysis was performed with the Levene's test, followed by a Student's t-test, besides the Pearson's chi-squared and Fischer's exact tests. Results: Proton magnetic resonance spectroscopy sensitivity, specificity and accuracy were, respectively, 87.5%, 92.3% and 90.9% (p < 0.0001). Statistically significant difference was observed in the slope (%/min) between benign (mean, 27.5%/min) and malignant (mean, 110.9%/min) lesions (p < 0.0001). Conclusion: The time-intensity curve and slope values using dynamic-enhanced perfusion magnetic resonance imaging in association with the presence of choline peak demonstrated by single voxel magnetic resonance spectroscopy study are useful in the differentiation between malignant and benign musculoskeletal tumors. (author)

  18. Imaging of Groin Pain: Magnetic Resonance and Ultrasound Imaging Features.

    Science.gov (United States)

    Lee, Susan C; Endo, Yoshimi; Potter, Hollis G

    Evaluation of groin pain in athletes may be challenging as pain is typically poorly localized and the pubic symphyseal region comprises closely approximated tendons and muscles. As such, magnetic resonance imaging (MRI) and ultrasound (US) may help determine the etiology of groin pain. A PubMed search was performed using the following search terms: ultrasound, magnetic resonance imaging, sports hernia, athletic pubalgia, and groin pain. Date restrictions were not placed on the literature search. Clinical review. Level 4. MRI is sensitive in diagnosing pathology in groin pain. Not only can MRI be used to image rectus abdominis/adductor longus aponeurosis and pubic bone pathology, but it can also evaluate other pathology within the hip and pelvis. MRI is especially helpful when groin pain is poorly localized. Real-time capability makes ultrasound useful in evaluating the pubic symphyseal region, as it can be used for evaluation and treatment. MRI and US are valuable in diagnosing pathology in athletes with groin pain, with the added utility of treatment using US-guided intervention. Strength-of Recommendation Taxonomy: C.

  19. Optically trapped atomic resonant devices for narrow linewidth spectral imaging

    Science.gov (United States)

    Qian, Lipeng

    This thesis focuses on the development of atomic resonant devices for spectroscopic applications. The primary emphasis is on the imaging properties of optically thick atomic resonant fluorescent filters and their applications. In addition, this thesis presents a new concept for producing very narrow linewidth light as from an atomic vapor lamp pumped by a nanosecond pulse system. This research was motivated by application for missile warning system, and presents an innovative approach to a wide angle, ultra narrow linewidth imaging filter using a potassium vapor cell. The approach is to image onto and collect the fluorescent photons emitted from the surface of an optically thick potassium vapor cell, generating a 2 GHz pass-band imaging filter. This linewidth is narrow enough to fall within a Fraunhefer dark zone in the solar spectrum, thus make the detection solar blind. Experiments are conducted to measure the absorption line shape of the potassium resonant filter, the quantum efficiency of the fluorescent behavior, and the resolution of the fluorescent image. Fluorescent images with different spatial frequency components are analyzed by using a discrete Fourier transform, and the imaging capability of the fluorescent filter is described by its Modulation Transfer Function. For the detection of radiation that is spectrally broader than the linewidth of the potassium imaging filter, the fluorescent image is seen to be blurred by diffuse fluorescence from the slightly off resonant photons. To correct this, an ultra-thin potassium imaging filter is developed and characterized. The imaging property of the ultra-thin potassium imaging cell is tested with a potassium seeded flame, yielding a resolution image of ˜ 20 lines per mm. The physics behind the atomic resonant fluorescent filter is radiation trapping. The diffusion process of the resonant photons trapped in the atomic vapor is theoretically described in this thesis. A Monte Carlo method is used to simulate the

  20. Cryogenic Preamplifiers for Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Johansen, Daniel H.; Sanchez-Heredia, Juan D.; Petersen, Jan R.

    2018-01-01

    Pursuing the ultimate limit of detection in magnetic resonance imaging (MRI) requires cryogenics to decrease the thermal noise of the electronic circuits. As cryogenic coils for MRI are slowly emerging cryogenic preamplifiers are required to fully exploit their potential. A cryogenic preamplifier...