WorldWideScience

Sample records for resin transfer material

  1. Resin infiltration transfer technique

    Science.gov (United States)

    Miller, David V [Pittsburgh, PA; Baranwal, Rita [Glenshaw, PA

    2009-12-08

    A process has been developed for fabricating composite structures using either reaction forming or polymer infiltration and pyrolysis techniques to densify the composite matrix. The matrix and reinforcement materials of choice can include, but are not limited to, silicon carbide (SiC) and zirconium carbide (ZrC). The novel process can be used to fabricate complex, net-shape or near-net shape, high-quality ceramic composites with a crack-free matrix.

  2. Modeling of ultrasonic wave propagation in composite materials obtained by the resin transfer molding process; Modelisation de la propagation ultrasonore dans les materiaux composites obtenus par le procede de fabrication RTM (Resin Transfer Molding)

    Energy Technology Data Exchange (ETDEWEB)

    Lonne, S.

    2003-11-01

    The Resin Transfer Molding process for manufacturing composite materials is used to produce parts of complex shape. During the ultrasonic examination of such parts, attenuation is measured to characterize possible porosity content (a potential defect in this material). However, strong variation of attenuation is observed including on sound plates. The present study aims at explaining this by developing a model for ultrasonic propagation and attenuation in such parts which complex microstructure exhibits a multiple-scale aspect. An original model has been developed to predict attenuation at the elementary scale of an unidirectional layer of carbon fibers in an epoxy matrix. It couples multiple scattering by fibers and viscoelastic losses phenomena. It has been experimentally validated and applies to arbitrary two-phase fiber reinforced composites whatever the fiber volume fraction. At the upper scale of a ply made of several elementary layers of various orientations, the anisotropic behavior of ultrasonic waves and their attenuation are obtained by a homogenization procedure. An actual plate is made of several plies separated by pure resin layers. Plies and layers thicknesses are highly variable. A statistical study has been conducted to evaluate the influence of these geometrical variations on the ultrasonic transmission predicted by a model derived from Thomson-Haskell formalism. Ultrasonic attenuation variability practically observed is quantitatively reproduced and explained as resulting from the geometrical irregularity of the microstructure. (author)

  3. Enhancement of adhesion between resin coating materials and resin cements.

    Science.gov (United States)

    Udo, Tomoaki; Nikaido, Toru; Ikeda, Masaomi; Weerasinghe, Dinesh S; Harada, Naoko; Foxton, Richard M; Tagami, Junji

    2007-07-01

    Resin coating technique is a unique method that improves the dentin bond strength of resin cements in indirect restorations. However, the weak link of a specimen bonded using the resin coating technique was reported to be the bonded interface between the resin coating material and resin cement. The purpose of this study, therefore, was to enhance the bonding performance between a resin coating material and a resin cement. Two light-cured flowable composites, Protect Liner F and Clearfil Flow FX, were used as coating materials, and two dual-cure composite materials, Panavia F 2.0 and Clearfil DC Core Automix, were used as resin cements. The ultimate tensile strength of each material and the microtensile bond strengths of the bonded specimens of resin coating material and resin cement were measured using a crosshead speed of 1.0 mm/min. Three-way ANOVA (p=0.05) revealed that the highest microtensile bond strength was obtained using a combination of Clearfil Flow FX and Clearfil DC Core Automix, and when the surface of the coating material was treated with ED Primer II. It was strongly suggested that materials with a higher ultimate tensile strength, when used in both resin coating and cementation, could enhance the bond strength between the two.

  4. Composite fabrication via resin transfer molding technology

    Energy Technology Data Exchange (ETDEWEB)

    Jamison, G.M.; Domeier, L.A.

    1996-04-01

    The IMPReS (Integrated Modeling and Processing of Resin-based Structures) Program was funded in FY95 to consolidate, evaluate and enhance Sandia`s capabilities in the design and fabrication of composite structures. A key driver of this and related programs was the need for more agile product development processes and for model based design and fabrication tools across all of Sandia`s material technologies. A team of polymer, composite and modeling personnel was assembled to benchmark Sandia`s existing expertise in this area relative to industrial and academic programs and to initiate the tasks required to meet Sandia`s future needs. RTM (Resin Transfer Molding) was selected as the focus composite fabrication technology due to its versatility and growing use in industry. Modeling efforts focused on the prediction of composite mechanical properties and failure/damage mechanisms and also on the uncured resin flow processes typical of RTM. Appropriate molds and test composites were fabricated and model validation studies begun. This report summarizes and archives the modeling and fabrication studies carried out under IMPReS and evaluates the status of composite technology within Sandia. It should provide a complete and convenient baseline for future composite technology efforts within Sandia.

  5. Geopolymer resin materials, geopolymer materials, and materials produced thereby

    Science.gov (United States)

    Seo, Dong-Kyun; Medpelli, Dinesh; Ladd, Danielle; Mesgar, Milad

    2016-03-29

    A product formed from a first material including a geopolymer resin material, a geopolymer resin, or a combination thereof by contacting the first material with a fluid and removing at least some of the fluid to yield a product. The first material may be formed by heating and/or aging an initial geopolymer resin material to yield the first material before contacting the first material with the fluid. In some cases, contacting the first material with the fluid breaks up or disintegrates the first material (e.g., in response to contact with the fluid and in the absence of external mechanical stress), thereby forming particles having an external dimension in a range between 1 nm and 2 cm.

  6. Geopolymer resin materials, geopolymer materials, and materials produced thereby

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Dong-Kyun; Medpelli, Dinesh; Ladd, Danielle; Mesgar, Milad

    2018-01-09

    A product formed from a first material including a geopolymer resin material, a geopolymer material, or a combination thereof by contacting the first material with a fluid and removing at least some of the fluid to yield a product. The first material may be formed by heating and/or aging an initial geopolymer resin material to yield the first material before contacting the first material with the fluid. In some cases, contacting the first material with the fluid breaks up or disintegrates the first material (e.g., in response to contact with the fluid and in the absence of external mechanical stress), thereby forming particles having an external dimension in a range between 1 nm and 2 cm.

  7. Physical Properties of Synthetic Resin Materials

    Science.gov (United States)

    Fishbein, Meyer

    1939-01-01

    A study was made to determine the physical properties of synthetic resins having paper, canvas, and linen reinforcements, and of laminated wood impregnated with a resin varnish. The results show that commercial resins have moduli of elasticity that are too low for structural considerations. Nevertheless, there do exist plastics that have favorable mechanical properties and, with further development, it should be possible to produce resin products that compare favorably with the light-metal alloys. The results obtained from tests on Compound 1840, resin-impregnated wood, show that this material can stand on its own merit by virtue of a compressive strength four times that of the natural wood. This increase in compressive strength was accomplished with an increase of density to a value slightly below three times the normal value and corrected one of the most serious defects of the natural product.

  8. The strengthening of resin cemented dental ceramic materials

    OpenAIRE

    Hooi, Paul

    2013-01-01

    The aim of the current investigation was to advance the understanding of the mechanism of resin-strengthening conferred to dental ceramic materials by resin-based composite materials. The investigation is presented as a series of manuscripts. In the first study (Manuscript 3.1), dental porcelain disc-shaped specimens were resin-coated with three resin-based composite materials with different flexural moduli at discrete resin thicknesses. The discs were loaded to failure in a biaxial flexure t...

  9. 21 CFR 872.3690 - Tooth shade resin material.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Tooth shade resin material. 872.3690 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3690 Tooth shade resin material. (a) Identification. Tooth shade resin material is a device composed of materials such as bisphenol-A glycidyl...

  10. 21 CFR 872.3670 - Resin impression tray material.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3670 Resin impression tray material. (a) Identification. Resin impression tray material is a device intended for use in a two-step dental mold fabricating... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Resin impression tray material. 872.3670 Section...

  11. 21 CFR 872.3310 - Coating material for resin fillings.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Coating material for resin fillings. 872.3310... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3310 Coating material for resin fillings. (a) Identification. A coating material for resin fillings is a device intended to be applied to the...

  12. The interaction between lining materials and composite resin restorative materials.

    Science.gov (United States)

    Lingard, G L; Davies, E H; Von Fraunhofer, J A

    1981-03-01

    The effects of four lining materials, Dycal, Procal, Cavitec and Poly F cement on Adaptic and Concise have been investigated in vitro. The parameters studied were surface roughness, hardness and colour both with and without an intermediate (or bonding) resin being present between the restorative material and the liner. The effects of the four liners on the composites varied both between the lining materials themselves and with the composite resin. Two materials, Procal and Dycal, had little interaction with the composites, provided an intermediate resin was used with the latter. Cavitec appeared to have an adverse reaction with the composites and Poly F, whilst having no effect on the colour of the composites, did increase surface roughness. The adverse effects of linig materials were ascribed to minor constituents, particularly methyl salicylate, present in the formulation.

  13. FDI report on adverse reactions to resin-based materials.

    Science.gov (United States)

    Fan, P L; Meyer, D M

    2007-02-01

    Resin-based restorative materials are considered safe for the vast majority of dental patients. Although constituent chemicals such as monomers, accelerators and initiators can potentially leach out of cured resin-based materials after placement, adverse reactions to these chemicals are rare and reaction symptoms commonly subside after removal of the materials. Dentists should be aware of the rare possibility that patients could have adverse reactions to constituents of resin-based materials and be vigilant in observing any adverse reactions after restoration placement. Dentists should also be cognisant of patient complaints about adverse reactions that may result from components of resin-based materials. To minimise monomer leaching and any potential risk of dermatological reactions, resin-based materials should be adequately cured. Dental health care workers should avoid direct skin contact with uncured resin-based materials. Latex and vinyl gloves do not provide adequate barrier protection to the monomers in resin-based materials.

  14. Dissolution of mega-voids in resin transfer molding

    OpenAIRE

    Clark, Paul Nordstrom

    2007-01-01

    Resin transfer molding (RTM) is a common composite manufacturing process. Voids are a common defect encountered in RTM components. A new type of void, the 'Mega-Void', has been identified and addressed by this research. To produce acceptable RTM components requires that the mega-void be eliminated either through prevention or through dissolution. The latter is the topic of this research. Three process parameters affecting mega-void dissolution are researched; 1) Preform/mold vacuum , 2) Resin...

  15. Homogeneous Liquid Phase Transfer of Graphene Oxide into Epoxy Resins.

    Science.gov (United States)

    Amirova, Lyaysan; Surnova, Albina; Balkaev, Dinar; Musin, Delus; Amirov, Rustem; Dimiev, Ayrat M

    2017-04-05

    The quality of polymer composite materials depends on the distribution of the filler in the polymer matrix. Due to the presence of the oxygen functional groups, graphene oxide (GO) has a strong affinity to epoxy resins, providing potential opportunity for the uniform distribution of GO sheets in the matrix. Another advantage of GO over its nonoxidized counterpart is its ability to exfoliate to single-atomic-layer sheets in water and in some organic solvents. However, these advantages of GO have not yet been fully realized due to the lack of the methods efficiently introducing GO into the epoxy resin. Here we develop a novel homogeneous liquid phase transfer method that affords uniform distribution, and fully exfoliated condition of GO in the polymer matrix. The most pronounced alteration of properties of the cured composites is registered at the 0.10%-0.15% GO content. Addition of as little as 0.10% GO leads to the increase of the Young's modulus by 48%. Moreover, we demonstrate successful introduction of GO into the epoxy matrix containing an active diluent-modifier; this opens new venues for fabrication of improved GO-epoxy-modifier composites with a broad range of predesigned properties. The experiments done on reproducing the two literature methods, using alternative GO introduction techniques, lead to either decrease or insignificant increase of the Young's modulus of the resulting GO-epoxy composites.

  16. Dental repair material: a resin-modified glass-ionomer bioactive ionic resin-based composite.

    Science.gov (United States)

    Croll, Theodore P; Berg, Joel H; Donly, Kevin J

    2015-01-01

    This report documents treatment and repair of three carious teeth that were restored with a new dental repair material that features the characteristics of both resin-modified glass-ionomer restorative cement (RMGI) and resin-based composite (RBC). The restorative products presented are reported by the manufacturer to be the first bioactive dental materials with an ionic resin matrix, a shock-absorbing resin component, and bioactive fillers that mimic the physical and chemical properties of natural teeth. The restorative material and base/liner, which feature three hardening mechanisms, could prove to be a notable advancement in the adhesive dentistry restorative materials continuum.

  17. Low-melt Viscosity Polyimide Resins for Resin Transfer Molding (RTM) II

    Science.gov (United States)

    Chuang, Kathy C.; Criss, Jim M.; Mintz, Eric A.; Scheiman, Daniel A.; Nguyen, Baochau N.; McCorkle, Linda S.

    2007-01-01

    A series of polyimide resins with low-melt viscosities in the range of 10-30 poise and high glass transition temperatures (Tg s) of 330-370 C were developed for resin transfer molding (RTM) applications. These polyimide resins were formulated from 2,3,3 ,4 -biphenyltetracarboxylic dianhydride (a-BPDA) with 4-phenylethynylphthalic anhydride endcaps along with either 3,4 - oxyaniline (3,4 -ODA), 3,4 -methylenedianiline, (3,4 -MDA) or 3,3 -methylenedianiline (3,3 -MDA). These polyimides had pot lives of 30-60 minutes at 260-280 C, enabling the successful fabrication of T650-35 carbon fiber reinforced composites via RTM process. The viscosity profiles of the polyimide resins and the mechanical properties of the polyimide carbon fiber composites will be discussed.

  18. Resin Flow in Fiber Preformed by Vacuum Assisted Resin Transfer Molding with Flexible Tools

    Directory of Open Access Journals (Sweden)

    M.M. Shokrieh

    2008-12-01

    Full Text Available Vacuum assisted resin transfer molding, as a sub-branch of RTM is a method of manufacturing composite specimens. Considering the industrial development of this method, different modified techniques are designed to improve its performance. Among these techniques, using a half flexible mold is regarded as an important method. In this work, dominant equations of resin flow through the mold in polar coordinates are solved analytically. Based on this approach, closed-form solutions have been presented for different parameters such as thickness variation of preformed fiber, resin pressure, resin velocity and fiber volume fraction as functions of two variables, namely, time and the distance from injection port. After verification of the approach employed in this work, the results are presented. Important parameters influencing the quality and the rate production are studied in detail.

  19. Resin transfer molding for advanced composite primary aircraft structures

    Science.gov (United States)

    Markus, Alan; Palmer, Ray

    1991-01-01

    Resin Transfer Molding (RTM) has been identified by Douglas Aircraft Company (DAC) and industry to be one of the promising processes being developed today which can break the cost barrier of implementing composite primary structures into a commercial aircraft production environment. The RTM process developments and scale-up plans Douglas Aircrart will be conducting under the NASA ACT contract are discussed.

  20. Radiopacity Of Glass-ionomer/composite Resin Hybrid Materials.

    OpenAIRE

    Hara A.T.; Serra M.C.; Rodrigues Junior A.L.

    2001-01-01

    This study visually compared the radiopacity of seven restorative materials (3 resin-modified glass-ionomer cements, 3 polyacid-modified composite resins, and 1 conventional glass-ionomer cement) to a sound tooth structure sample, and an aluminium stepwedge. All hybrid materials were more radiopaque, except for one resin-modified glass-ionomer cement, than both the tooth structure and conventional glass-ionomer cement.

  1. Material Transfer Agreement (MTA) | FNLCR

    Science.gov (United States)

    Material Transfer Agreements are appropriate for exchange of materials into or out of the Frederick National Laboratory for research or testing purposes, with no collaborative research by parties involving the materials.

  2. Radiation processed composite materials of wood and elastic polyester resins

    International Nuclear Information System (INIS)

    Tapolcai, I.; Czvikovszky, T.

    1983-01-01

    The radiation polymerization of multifunctional unsaturated polyester-monomer mixtures in wood forms interpenetrating network system. The mechanical resistance (compression, abrasion, hardness, etc.) of these composite materials are generally well over the original wood, however the impact strength is almost the same or even reduced, in comparison to the wood itself. An attempt is made using elastic polyester resins to produced wood-polyester composite materials with improved modulus of elasticity and impact properties. For the impregnation of European beech wood two types of elastic unsaturated polyester resins were used. The exothermic effect of radiation copolymerization of these resins in wood has been measured and the dose rate effects as well as hardening dose was determined. Felxural strength and impact properties were examined. Elastic unsaturated polyester resins improved the impact strength of wood composite materials. (author)

  3. Degradation, Fatigue, and Failure of Resin Dental Composite Materials

    Energy Technology Data Exchange (ETDEWEB)

    Drummond, J.L. (UIC)

    2008-11-03

    The intent of this article is to review the numerous factors that affect the mechanical properties of particle- or fiber-filler-containing indirect dental resin composite materials. The focus will be on the effects of degradation due to aging in different media, mainly water and water and ethanol, cyclic loading, and mixed-mode loading on flexure strength and fracture toughness. Several selected papers will be examined in detail with respect to mixed and cyclic loading, and 3D tomography with multi-axial compression specimens. The main cause of failure, for most dental resin composites, is the breakdown of the resin matrix and/or the interface between the filler and the resin matrix. In clinical studies, it appears that failure in the first 5 years is a restoration issue (technique or material selection); after that time period, failure most often results from secondary decay.

  4. Characterization of high-pressure resin transfer molding process variants for manufacturing high-performance composites

    OpenAIRE

    Chaudhari, Raman

    2014-01-01

    The current developments in the Resin Transfer Molding (RTM) process for the automotive industry are strongly driven by the need for automotive light-weight design and high volume manufacturing capacity. In order to adapt the RTM process for industrial scale manufacturing of the automotive components it is essential to implement newly developed fast curing resin systems. If such resin systems shall be implemented in the RTM process, then it raises the necessity to achieve shorter resin inject...

  5. Simulation of Air Entrapment and Resin Curing During Manufacturing of Composite Cab Front by Resin Transfer Moulding Process

    Directory of Open Access Journals (Sweden)

    Kuppusamy Raghu Raja Pandiyan

    2017-09-01

    Full Text Available Mould filling and subsequent curing are the significant processing stages involved in the production of a composite component through Resin Transfer Moulding (RTM fabrication technique. Dry spot formation and air entrapment during filling stage caused by improper design of filling conditions and locations that lead to undesired filling patterns resulting in defective RTM parts. Proper placement of inlet ports and exit vents as well as by adjustment of filling conditions can alleviate the problems during the mould filling stage. The temperature profile used to polymerize the resin must be carefully chosen to reduce the cure time. Instead of trial and error methods that are expensive, time consuming, and non-optimal, we propose a simulation-based optimization strategy for a composite cab front component to reduce the air entrapment and cure stage optimization. In order to be effective, the optimization strategy requires an accurate simulation of the process utilizing submodels to describe the raw material characteristics. Cure reaction kinetics and chemo-rheology were the submodels developed empirically for an unsaturated polyester resin using experimental data. The simulations were performed using commercial software PAM RTM 2008, developed by ESI Technologies. Simulation results show that the use of increase in injection pressure at the inlet filling conditions greatly reduce the air entrapped. For the cab front, the alteration of injection pressure with proper timing of vent opening reduced the air entrapped during mould filling stage. Similarly, the curing simulation results show that the use of higher mould temperatures effectively decreases the cure time as expected.

  6. Preparation and Characterizations of Composite Material Based on Carbon Fiber and Two Thermoset Resins

    OpenAIRE

    Fouda Hany; Guo Lin; Elsharkawy Karim

    2017-01-01

    In the present investigation, we used two types of thermoset resins (epoxy resin and phenol formaldehyde resin) with carbon fiber (CF) to produce composite materials. CF/epoxy resin composite and CF/phenolformaldhyde resin composite were fabricated and compared between their mechanical properties as compression, tension and flexural. it was found that mechanical properties of CF/epoxy composite higher than mechanical properties of CF/phenolformaldhyde resin composite such as flexural strength...

  7. Governance of material transfer agreements

    NARCIS (Netherlands)

    Rodriguez, V.F.

    2008-01-01

    The governance of material transfer agreements (MTAs) is crucial for research and the progress of science. When developing a research project, researchers face the problem of availability of research material or restrictive provisions imposed by providers. This article discusses the governance of

  8. Aerospace Composite Materials Delivery Order 0003: Nanocomposite Polymeric Resin Enhancements for Improved Composite Performance

    National Research Council Canada - National Science Library

    Chen, Chenggang

    2002-01-01

    .... The addition of clays does not significantly alter the viscosity or cure kinetics so that the modified resin will still be suitable for liquid composite molding techniques such as resin transfer molding...

  9. Preparation and Characterizations of Composite Material Based on Carbon Fiber and Two Thermoset Resins

    Directory of Open Access Journals (Sweden)

    Fouda Hany

    2017-01-01

    Full Text Available In the present investigation, we used two types of thermoset resins (epoxy resin and phenol formaldehyde resin with carbon fiber (CF to produce composite materials. CF/epoxy resin composite and CF/phenolformaldhyde resin composite were fabricated and compared between their mechanical properties as compression, tension and flexural. it was found that mechanical properties of CF/epoxy composite higher than mechanical properties of CF/phenolformaldhyde resin composite such as flexural strength of CF/epoxy resin composite increased by 30 % than flexural strength of CF/phenolformaldhyde resin composite, tensile strength of CF/epoxy resin composite increased by 11.4 % than flexural strength of CF/phenolformaldhyde resin and axial compression strength of CF/epoxy resin composite increased by 14.5 % than flexural strength of CF/phenolformaldhyde resin.

  10. CURING OF POLYMERIC COMPOSITES USING MICROWAVE RESIN TRANSFER MOULDING (RTM

    Directory of Open Access Journals (Sweden)

    R. YUSOFF

    2007-08-01

    Full Text Available The main objective of this work is to compare the difference between microwave heating and conventional thermal heating in fabricating carbon/epoxy composites. Two types of epoxy resin systems were used as matrices, LY5052-HY5052 and DGEBA-HY917-DY073. All composite samples were fabricated using resin transfer moulding (RTM technique. The curing of the LY5052-HY5052-carbon and the DGEBA-HY917-DY073-carbon composite systems, were carried out at 100 °C and 120 °C, respectively. Microwave heating showed better temperature control than conventional heating, however, the heating rate of the microwave cured samples were slower than the conventionally cured samples. This was attributed to the lower power (250 W used when heating with microwaves compared to 2000 W used in conventional heating. Study of thermal characteristics as curing progressed showed that the polymerisation reaction occurred at a faster rate during microwave curing than in conventional curing for both the DGEBA and the LY/HY5052 carbon composite systems. The actual cure cycle was reduced from 60 minutes to 40 minutes when using microwaves for curing DGEBA-carbon composites. As for LY/HY5052-carbon composites, the actual cure cycle was reduced from 3 hours to 40 minutes. Both conventional and microwave heating yielded similar glass transition temperatures (120 °C for DGEBA systems and 130 °C for LY/HY5052 systems. Microwave cured composites had higher void contents than conventionally cured composites (2.2-2.8% and 1.8-2.4% for DGEBA and LY/HY5052 microwave cured composites, respectively, compared to 0.2-0.4% for both DGEBA and LY/HY5052 thermally cured composites. C-scan traces showed that all composites, regardless of methods of curing, had minimal defects.

  11. Characterization of selected LDEF polymer matrix resin composite materials

    Science.gov (United States)

    Young, Philip R.; Slemp, Wayne S.; Witte, William G., Jr.; Shen, James Y.

    1991-01-01

    The characterization of selected graphite fiber reinforced epoxy (934 and 5208) and polysulfone (P1700) matrix resin composite materials which received 5 years and 10 months of exposure to the LEO environment on the Long Duration Exposure Facility is reported. Resin loss and a decrease in mechanical performance as well as dramatic visual effects were observed. However, chemical characterization including infrared, thermal, and selected solution property measurements showed that the molecular structure of the polymeric matrix had not changed significantly in response to this exposure. The potential effect of a silicon-containing molecular contamination of these specimens is addressed.

  12. Nonlinear Inelastic Mechanical Behavior Of Epoxy Resin Polymeric Materials

    Science.gov (United States)

    Yekani Fard, Masoud

    Polymer and polymer matrix composites (PMCs) materials are being used extensively in different civil and mechanical engineering applications. The behavior of the epoxy resin polymers under different types of loading conditions has to be understood before the mechanical behavior of Polymer Matrix Composites (PMCs) can be accurately predicted. In many structural applications, PMC structures are subjected to large flexural loadings, examples include repair of structures against earthquake and engine fan cases. Therefore it is important to characterize and model the flexural mechanical behavior of epoxy resin materials. In this thesis, a comprehensive research effort was undertaken combining experiments and theoretical modeling to investigate the mechanical behavior of epoxy resins subject to different loading conditions. Epoxy resin E 863 was tested at different strain rates. Samples with dog-bone geometry were used in the tension tests. Small sized cubic, prismatic, and cylindrical samples were used in compression tests. Flexural tests were conducted on samples with different sizes and loading conditions. Strains were measured using the digital image correlation (DIC) technique, extensometers, strain gauges, and actuators. Effects of triaxiality state of stress were studied. Cubic, prismatic, and cylindrical compression samples undergo stress drop at yield, but it was found that only cubic samples experience strain hardening before failure. Characteristic points of tensile and compressive stress strain relation and load deflection curve in flexure were measured and their variations with strain rate studied. Two different stress strain models were used to investigate the effect of out-of-plane loading on the uniaxial stress strain response of the epoxy resin material. The first model is a strain softening with plastic flow for tension and compression. The influence of softening localization on material behavior was investigated using the DIC system. It was found that

  13. Fissure sealant materials: Wear resistance of flowable composite resins.

    Science.gov (United States)

    Asefi, Sohrab; Eskandarion, Solmaz; Hamidiaval, Shadi

    2016-01-01

    Background. Wear resistance of pit and fissure sealant materials can influence their retention. Wear characteristics of sealant materials may determine scheduling of check-up visits. The aim of this study was to compare wear resistance of two flowable composite resins with that of posterior composite resin materials. Methods. Thirty-five disk-shaped specimens were prepared in 5 groups, including two flowable composite resins (Estelite Flow Quick and Estelite Flow Quick High Flow), Filtek P90 and Filtek P60 and Tetric N-Ceram. The disk-shaped samples were prepared in 25-mm diameter by packing them into a two-piece aluminum mold and then light-cured. All the specimens were polished for 1minute using 600-grit sand paper. The samples were stored in distilled water at room temperature for 1 week and then worn by two-body abrasion test using "pin-on-disk" method (with distilled water under a 15-Nload at 0.05 m/s, for a distance of 100 meter with Steatite ceramic balls antagonists). A Profilometer was used for evaluating the surface wear. Data were analyzed with the one-way ANOVA. Results. Estelite Flow Quick exhibited 2708.9 ± 578.1 μm(2) and Estelite Flow Quick High Flow exhibited 3206 ± 2445.1 μm(2)of wear but there were no significant differences between the groups. They demonstrated similar wear properties. Conclusion. Estelite flowable composite resins have wear resistance similar to nano- and micro-filled and micro-hybrid composite resins. Therefore, they can be recommended as pit and fissure sealant materials in the posterior region with appropriate mechanical characteristics.

  14. Fissure sealant materials: Wear resistance of flowable composite resins

    Directory of Open Access Journals (Sweden)

    Sohrab Asefi

    2016-08-01

    Full Text Available Background. Wear resistance of pit and fissure sealant materials can influence their retention. Wear characteristics of sealant materials may determine scheduling of check-up visits. The aim of this study was to compare wear resistance of two flowable composite resins with that of posterior composite resin materials. Methods. Thirty-five disk-shaped specimens were prepared in 5 groups, including two flowable composite resins (Estelite Flow Quick and Estelite Flow Quick High Flow, Filtek P90 and Filtek P60 and Tetric N-Ceram. The disk-shaped samples were prepared in 25-mm diameter by packing them into a two-piece aluminum mold and then light-cured. All the specimens were polished for 1minute using 600-grit sand paper. The samples were stored in distilled water at room temperature for 1 week and then worn by two-body abrasion test using "pin-on-disk" method (with distilled water under a 15-Nload at 0.05 m/s, for a distance of 100 meter with Steatite ceramic balls antagonists. A Profilometer was used for evaluating the surface wear. Data were analyzed with the one-way ANOVA. Results. Estelite Flow Quick exhibited 2708.9 ± 578.1 μm2 and Estelite Flow Quick High Flow exhibited 3206 ± 2445.1 μm2of wear but there were no significant differences between the groups. They demonstrated similar wear properties. Conclusion. Estelite flowable composite resins have wear resistance similar to nano- and micro-filled and micro-hybrid composite resins. Therefore, they can be recommended as pit and fissure sealant materials in the posterior region with appropriate mechanical characteristics.

  15. Epoxy resin synthesis using low molecular weight lignin separated from various lignocellulosic materials.

    Science.gov (United States)

    Asada, Chikako; Basnet, Sunita; Otsuka, Masaya; Sasaki, Chizuru; Nakamura, Yoshitoshi

    2015-03-01

    A low molecular weight lignin from various lignocellulosic materials was used for the synthesis of bio-based epoxy resins. The lignin extracted with methanol from steam-exploded samples (steaming time of 5 min at steam pressure of 3.5 MPa) from different biomasses (i.e., cedar, eucalyptus, and bamboo) were functionalized by the reaction with epichlorohydrin, catalyzed by a water-soluble phase transfer catalyst tetramethylammonium chloride, which was further reacted with 30 wt% aqueous NaOH for ring closure using methyl ethyl ketone as a solvent. The glycidylated products of the lignin with good yields were cured to epoxy polymer networks with bio-based curing agents i.e., lignin itself and a commercial curing agent TD2131. Relatively good thermal properties of the bio-based epoxy network was obtained and thermal decomposition temperature at 5% weight loss (Td5) of cedar-derived epoxy resin was higher than that derived from eucalyptus and bamboo. The bio-based resin satisfies the stability requirement of epoxy resin applicable for electric circuit boards. The methanol-insoluble residues were enzymatically hydrolyzed to produce glucose. This study indicated that the biomass-derived methanol-soluble lignin may be a promising candidate to be used as a substitute for petroleum-based epoxy resin derived from bisphenol A, while insoluble residues may be processed to give a bioethanol precursor i.e., glucose. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Resin Flow Analysis in the Injection Cycle of a Resin Transfer Molded Radome

    Science.gov (United States)

    Golestanian, Hossein; Poursina, Mehrdad

    2007-04-01

    Resin flow analysis in the injection cycle of an RTM process was investigated. Fiberglass and carbon fiber mats were used as reinforcements with EPON 826 epoxy resin. Numerical models were developed in ANSYS finite element software to simulate resin flow behavior into a mold of conical shape. Resin flow into the woven fiber mats is modeled as flow through porous media. The injection time for fiberglass/epoxy composite is found to be 4407 seconds. Required injection time for the carbon/epoxy composite is 27022 seconds. Higher injection time for carbon/epoxy part is due to lower permeability value of the carbon fibers compared to glass fiber mat.

  17. Ceramics for Molten Materials Transfer

    Science.gov (United States)

    Standish, Evan; Stefanescu, Doru M.; Curreri, Peter A.

    2009-01-01

    The paper reviews the main issues associated with molten materials transfer and handling on the lunar surface during the operation of a hig h temperature electrowinning cell used to produce oxygen, with molten iron and silicon as byproducts. A combination of existing technolog ies and purposely designed technologies show promise for lunar exploi tation. An important limitation that requires extensive investigation is the performance of refractory currently used for the purpose of m olten metal containment and transfer in the lunar environment associa ted with electrolytic cells. The principles of a laboratory scale uni t at a scale equivalent to the production of 1 metric ton of oxygen p er year are introduced. This implies a mass of molten materials to be transferred consistent with the equivalent of 1kg regolithlhr proces sed.

  18. Development of epoxy resin-type neutron shielding materials (I)

    International Nuclear Information System (INIS)

    Cho, Soo Haeng; Kim, Ik Soo; Shin, Young Joon; Do, Jae Bum; Ro, Seung Gy.

    1997-12-01

    Because the exposure to radiation in the nuclear facilities can be fatal to human, it is important to reduce the radiation dose level to a tolerable level. The purpose of this study is to develop highly effective neutron shielding materials for the shipping and storage cask of radioactive materials or in the nuclear /radiation facilities. On this study, we developed epoxy resin based neutron shielding materials and their various materials properties, including neutron shielding ability, fire resistance, combustion characteristics, radiation resistance, thermal and mechanical properties were evaluated experimentally. (author). 31 refs., 22 tabs., 17 figs

  19. Fabrication of detail parts for superconducting magnets by resin transfer molding

    International Nuclear Information System (INIS)

    Behan, M.R.; Hartmann, J.G.

    1993-01-01

    A method is described of fabricating a detail part for a superconducting magnet and also of fabricating a coil winding assembly for a superconducting magnet, comprising the steps of: (a) utilizing engineering specifications for a detail part to produce a master mold part for the detail part, while taking into account a calculated resin shrinkage factor; (b) utilizing the master mold part to fabricate a resin transfer mold for the detail part; (c) placing a preform for the detail part into the resin transfer mold and closing the mold with the preform therein; (d) injecting a two-stage curing resin into the resin transfer mold; (e) heating the resin transfer mold to partially cure the molded detail part; (f) removing the partially cured detail part from the resin transfer mold; (g) fabricating a coil winding assembly, while precisely positioning the partially cured detail part relative to the coil windings to produce a coil winding assembly; (h) placing the coil winding assembly into a curing press, and pressing and heating the coil winding assembly in the curing press, during which the detail part conforms to the coil winding and cures completely to produce a final coil winding assembly for a superconducting magnet

  20. Interpenetrating network ceramic-resin composite dental restorative materials.

    Science.gov (United States)

    Swain, M V; Coldea, A; Bilkhair, A; Guess, P C

    2016-01-01

    This paper investigates the structure and some properties of resin infiltrated ceramic network structure materials suitable for CAD/CAM dental restorative applications. Initially the basis of interpenetrating network materials is defined along with placing them into a materials science perspective. This involves identifying potential advantages of such structures beyond that of the individual materials or simple mixing of the components. Observations from a number of recently published papers on this class of materials are summarized. These include the strength, fracture toughness, hardness and damage tolerance, namely to pointed and blunt (spherical) indentation as well as to burr adjustment. In addition a summary of recent results of crowns subjected to simulated clinical conditions using a chewing simulator are presented. These results are rationalized on the basis of existing theoretical considerations. The currently available ceramic-resin IPN material for clinical application is softer, exhibits comparable strength and fracture toughness but with substantial R-curve behavior, has lower E modulus and is more damage tolerant than existing glass-ceramic materials. Chewing simulation observations with crowns of this material indicate that it appears to be more resistant to sliding/impact induced cracking although its overall contact induced breakage load is modest. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  1. On-line in-situ control of the resin transfer molding process

    Science.gov (United States)

    Kranbuehl, D.; Eichinger, D.; Williamson, A.; Levy, D.; Reyzer, M.

    1990-01-01

    Resin transfer molding of three-dimensionally stitched fabrics promises to be a cost effective process for obtaining composite parts of exceptional strength. The technique eliminates many problems involving prepreg preparation, storage and layup. It replaces, on the other hand, the single step cure process with a two-stage impregnation and cure process. Of particular importance therefore is selecting and controlling the viscosity during impregnation and cure. The use of in-situ frequency-dependent electromagnetic sensors and the Loos-Springer model for selecting and controllng the processing properties of the resin transfer molding resin during impregnation and cure are discussed.

  2. Selecting the Best Materials Compositions of Resin Based Bioasphalt

    Science.gov (United States)

    Setyawan, Ary; Widiharjo, Budi; Djumari

    2017-07-01

    Damar asphalt is one type of bioaspal which is a mixture with the main ingredient is a resin as a binder and cooking oil as a solvent. One major drawback of this damar asphalt is the low ductility. To improve the ductility values, then use the added material Filler. Filler serves as a divider between the impurities with damar asphalt, increases ductility and increase the ability of cohesion or bonding between the particles of material damar asphalt. The purpose of this study was to determine damar asphalt modifications to the properties in accordance with the properties of damar asphalt test specifications based on the value of penetration. This method uses some variant on material such as powder bricks and fly ash as a binder. Solvent in constituent used oil and used cooking oil. It also added the polymer latex up to 10% at intervals of 2%. The best composition of damar asphalt materials were obtained with gum rosin, Fly Ash, Oil and Latex. Damar asphalt modification damar asphalt optimum mix of resin (100g pure resin or resin chunk + 350g powder), Fly Ash powder (150g), cooking oil (205g), and latex 4%, ductility increased from 63.5 cm to 119.5 cm, the value of the flash point was originally at temperature of 240 °C to 260 °C, damar asphalt penetration of 68.2 dmm to 43 dmm, and the value of density decreases from 1.01 g / cm3 to 0.99 g / cm3. Damar asphalt at these modifications meet the specifications in terms of solubility in trichlore ethylene is equal to 99.5%, and also meet the affinity of damar asphalt at 99%. With the optimum value, damar asphalt could be categorized as bitumen 40/60 penetration.

  3. High Temperature Transfer Molding Resins: Preliminary Composite Properties of PETI-375

    Science.gov (United States)

    Connell, J. W.; Smith, J. G., Jr.; Hergenrother, P. M.; Criss, J. M., Jr.

    2004-01-01

    As part of an ongoing effort to develop materials for resin transfer molding (RTM) of high performance/high temperature composites, a new phenylethynyl containing imide designated as PETI-375 has been under evaluation. PETI-375 was prepared using 2,3,3 ,4 - biphenyltetracarboxylic dianhydride (a-BPDA), 1,3-bis(4-aminophenoxy)benzene and 2,2 - bis(trifluoromethyl)benzidine and endcapped with 4-phenylethynylphthalic anhydride. This material exhibited a stable melt viscosity of 0.1-0.4 Pa sec at 280 C. High quality, void-free laminates were fabricated by high temperature RTM using unsized T-650 carbon fabric and evaluated. After curing for 1 hour at 371 C, the laminates exhibited a glass transition temperature of approx. 375 C by thermomechanical analysis. The laminates were essentially void and microcrack free as evidenced by optical microscopic examination. The chemistry, physical, and composite properties of PETI-375 will be discussed.

  4. Diffusion through composite materials made with thermosetting resins

    International Nuclear Information System (INIS)

    Morin, Bruno.

    1981-08-01

    Medium and low-level radioactive wastes may be coated in a solid matrix mainly made with thermosetting resins: the study of water and cesium migration through composite materials made with thermosetting resins is usefull to compare the water tightness of different coatings. Disks with a thickness of two millimeters were used to measure the water absorption. Diffusion cells including a plane membrane the thickness of which was at least 70μ were used to measure the diffusion of cesium 137. The diffusion coefficient of water in pure thermosetting resins, polyester or epoxyde, is about 10 -9 cm 2 .s -1 ; the diffusion coefficients of cesium in the same materials are about 10 -12 cm 2 .s -1 ; the introduction of solid particles in these polymers generally induces an acceleration of the diffusion process: the diffusion coefficient may reach 10 -8 cm 2 .s -1 . This lost of water-tightness may be reduced either by rendering insoluble the filler mixed to the polymer, or by diminushing the porosity of the interfacial zones by improving the bonding between the polymer and the filler [fr

  5. Polyimide Composites Properties of RTM370 Fabricated by Vacuum Assisted Resins Transfer Molding (VARTM)

    Science.gov (United States)

    Chuang, Kathy C.; Criss, Jim M.; Mintz, Eric A.

    2011-01-01

    RTM370 imide resin based on 2,3,3 ,4 -biphenyl dianhydride ( a-BPDA), 3,4 -oxydianinline (3,4 -ODA) with 4-phenylethynylphthalic (PEPA) endcap has shown to exhibit high Tg (370 C) and low melt viscosity (10-30 poise) at 280 C with a pot-life of 1-2 h. Previously, RTM370 resin has been fabricated into composites with T650-35 carbon fabrics by resin transfer molding (RTM) successfully. RTM370 composites exhibit excellent mechanical properties up to 327 C (620 F), and outstanding property retention after aging at 288 C (550 F) for 1000 hrs. In this presentation, RTM 370 composites will be fabricated by vacuum assisted resins transfer molding (VARTM), using vacuum bags without mold. The mechanical properties of RTM370 composites fabricated by VARTM will be compared to those of RTM370 made by RTM.

  6. Composite Properties of RTM370 Polyimide Fabricated by Vacuum Assisted Resin Transfer Molding (VARTM)

    Science.gov (United States)

    Chuang, Kathy C.; Criss, James M.; Mintz, Eric A.; Shonkwiler, Brian; McCorkle, Linda S.

    2011-01-01

    RTM370 imide resin based on 2,3,3?,4?-biphenyl dianhydride (a-BPDA), 3,4'-oxydianinline (3,4'-ODA) with the 4-phenylethynylphthalic (PEPA) endcap has been shown to exhibit a high cured T(sub g) (370 C) and low melt viscosity (10-30 poise) at 280 C with a pot-life of 1-2 h. Previously, RTM370 resin has been successfully fabricated into composites reinforced with T650-35 carbon fabrics by resin transfer molding (RTM). RTM370 composites exhibit excellent mechanical properties up to 327?C (620?F), and outstanding property retention after aging at 288?C (550?F) for 1000 h. In this work, RTM370 composites were fabricated by vacuum assisted resin transfer molding (VARTM), using vacuum bags on a steel plate. The mechanical properties of RTM370 composites fabricated by VARTM are compared to those prepared by RTM.

  7. Neutron shielding material based on colemanite and epoxy resin.

    Science.gov (United States)

    Okuno, Koichi

    2005-01-01

    In recent years, there has been a need for compact shielding design such as self-shielding of a PET cyclotron or upgradation of radiation machinery in existing facilities. In these cases, high performance shielding materials are needed. Concrete or polyethylene have been used for a neutron shield. However, for compact shielding, they fall short in terms of performance or durability. Therefore, a new type of neutron shielding material based on epoxy resin and colemanite has been developed. Slab attenuation experiments up to 40 cm for the new shielding material were carried out using a 252Cf neutron source. Measurement was carried out using a REM-counter, and compared with calculation. The results show that the shielding performance is better than concrete and polyethylene mixed with 10 wt% boron oxide. From the result, we confirmed that the performance of the new material is suitable for practical use.

  8. Chairside resin-based provisional restorative materials for fixed prosthodontics.

    Science.gov (United States)

    Strassler, Howard E; Lowe, Robert A

    2011-01-01

    Provisional restorations are vital to fixed prosthodontics treatment, providing an important diagnostic function while in place. In addition to protecting the prepared teeth, provisionalization enables clinicians to refine biologic and biomechanical issues before the final restoration is fabricated. Adjustments can be made in the provisional restoration to achieve both the clinician's and patient's desired results. The fabrication of temporary restorations requires that clinicians be proficient with a variety of materials and techniques that can be used to make well-adapted and functional provisionals. There are many material choices available to temporize a single crown as well as multi-unit fixed partial dentures, and the selection of provisional materials should be made based on a case-by-case evaluation. This article provides a review of polymeric resin provisional materials.

  9. Microhardness of resin composite materials light-cured through fiber reinforced composite.

    NARCIS (Netherlands)

    Fennis, W.M.M.; Ray, N.J.; Creugers, N.H.J.; Kreulen, C.M.

    2009-01-01

    OBJECTIVES: To compare polymerization efficiency of resin composite basing materials when light-cured through resin composite and fiber reinforced composite (FRC) by testing microhardness. METHODS: Simulated indirect restorations were prepared by application of resin composite (Clearfil AP-X) or FRC

  10. Evaluation of shrinkage polymerization and temperature of different acrylic resins used to splinting transfer copings in indirect impression technique

    Science.gov (United States)

    Franco, Ana Paula G. O.; Karam, Leandro Z.; Galvão, José R.; Kalinowski, Hypolito J.

    2015-09-01

    The aim of the present study was evaluate the shrinkage polymerization and temperature of different acrylic resins used to splinting transfer copings in indirect impression technique. Two implants were placed in an artificial bone, with the two transfer copings joined with dental floss and acrylic resins; two dental resins are used. Measurements of deformation and temperature were performed with Fiber Braggs grating sensor for 17 minutes. The results revealed that one type of resin shows greater values of polymerization shrinkage than the other. Pattern resins did not present lower values of shrinkage, as usually reported by the manufacturer.

  11. Fracture Resistance of Endodontically Treated Teeth Restored with Biodentine, Resin Modified GIC and Hybrid Composite Resin as a Core Material.

    Science.gov (United States)

    Subash, Dayalan; Shoba, Krishnamma; Aman, Shibu; Bharkavi, Srinivasan Kumar Indu; Nimmi, Vijayan; Abhilash, Radhakrishnan

    2017-09-01

    The restoration of a severely damaged tooth usually needs a post and core as a part of treatment procedure to provide a corono - radicular stabilization. Biodentine is a class of dental material which possess high mechanical properties with excellent biocompatibility and bioactive behaviour. The sealing ability coupled with optimum physical properties could make Biodentine an excellent option as a core material. The aim of the study was to determine the fracture resistance of Biodentine as a core material in comparison with resin modified glass ionomer and composite resin. Freshly extracted 30 human permanent maxillary central incisors were selected. After endodontic treatment followed by post space preparation and luting of Glass fibre post (Reforpost, Angelus), the samples were divided in to three groups based on the type of core material. The core build-up used in Group I was Biodentine (Septodont, France), Group II was Resin-Modified Glass Ionomer Cement (GC, Japan) and Group III was Hybrid Composite Resin (TeEconom plus, Ivoclar vivadent). The specimens were subjected to fracture toughness using Universal testing machine (1474, Zwick/Roell, Germany) and results were compared using One-way analysis of variance with Tukey's Post hoc test. The results showed that there was significant difference between groups in terms of fracture load. Also, composite resin exhibited highest mean fracture load (1039.9 N), whereas teeth restored with Biodentine demonstrated the lowest mean fracture load (176.66 N). Resin modified glass ionomer exhibited intermediate fracture load (612.07 N). The primary mode of failure in Group I and Group II was favourable (100%) while unfavourable fracture was seen in Group III (30%). Biodentine, does not satisfy the requirements to be used as an ideal core material. The uses of RMGIC's as a core build-up material should be limited to non-stress bearing areas. Composite resin is still the best core build-up material owing to its high fracture

  12. Effect of silver nanoparticles incorporation on viscoelastic properties of acrylic resin denture base material

    OpenAIRE

    Mahross, Hamada Zaki; Baroudi, Kusai

    2015-01-01

    Objective: The objective was to investigate the effect of silver nanoparticles (AgNPs) incorporation on viscoelastic properties of acrylic resin denture base material. Materials and Methods: A total of 20 specimens (60 ? 10 ? 2 mm) of heat cured acrylic resin were constructed and divided into four groups (five for each), according to the concentration of AgNPs (1%, 2%, and 5% vol.) which incorporated into the liquid of acrylic resin material and one group without additives (control group). Th...

  13. Microtensile bond strength of indirect resin composite to resin-coated dentin: interaction between diamond bur roughness and coating material.

    Science.gov (United States)

    Kameyama, Atsushi; Oishi, Takumi; Sugawara, Toyotarou; Hirai, Yoshito

    2009-02-01

    This aim of this study was to determine the effect of type of bur and resin-coating material on microtensile bond strength (microTBS) of indirect composite to dentin. Dentin surfaces were first ground with two types of diamond bur and resin-coated using UniFil Bond (UB) or Adper Single Bond (SB), and then bonded to a resin composite disc for indirect restoration with adhesive resin cement. After storage for 24 hr in distilled water at 37 degrees C, microTBS was measured (crosshead speed 1 mm/min). When UB was applied to dentin prepared using the regular-grit diamond bur, microTBS was significantly lower than that in dentin prepared using the superfine-grit bur. In contrast, no significant difference was found between regular-grit and superfine-grit bur with SB. However, more than half of the superfine-grit specimens failed before microTBS testing. These results indicate that selection of bur type is important in improving the bond strength of adhesive resin cement between indirect resin composite and resin-coated dentin.

  14. 49 CFR 173.173 - Paint, paint-related material, adhesives, ink and resins.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Paint, paint-related material, adhesives, ink and... Than Class 1 and Class 7 § 173.173 Paint, paint-related material, adhesives, ink and resins. (a) When..., paint-related material, adhesives, ink and resins must be packaged as follows: (1) As prescribed in...

  15. Material Transfer Agreement (MTA) | FNLCR Staging

    Science.gov (United States)

    Material Transfer Agreements are appropriate for exchange of materials into or out of the Frederick National Labfor research or testing purposes, with no collaborative research by parties involving the materials.

  16. Acoustic Performance of Resilient Materials Using Acrylic Polymer Emulsion Resin

    Directory of Open Access Journals (Sweden)

    Haseog Kim

    2016-07-01

    Full Text Available There have been frequent cases of civil complaints and disputes in relation to floor impact noises over the years. To solve these issues, a substantial amount of sound resilient material is installed between the concrete slab and the foamed concrete during construction. A new place-type resilient material is made from cement, silica powder, sodium sulfate, expanded-polystyrene, anhydrite, fly ash, and acrylic polymer emulsion resin. Its physical characteristics such as density, compressive strength, dynamic stiffness, and remanent strain are analyzed to assess the acoustic performance of the material. The experimental results showed the density and the dynamic stiffness of the proposed resilient material is increased with proportional to the use of cement and silica powder due to the high contents of the raw materials. The remanent strain, related to the serviceability of a structure, is found to be inversely proportional to the density and strength. The amount of reduction in the heavyweight impact noise is significant in a material with high density, high strength, and low remanent strain. Finally, specimen no. R4, having the reduction level of 3 dB for impact ball and 1 dB for bang machine in the single number quantity level, respectively, is the best product to obtain overall acoustic performance.

  17. Acoustic Performance of Resilient Materials Using Acrylic Polymer Emulsion Resin.

    Science.gov (United States)

    Kim, Haseog; Park, Sangki; Lee, Seahyun

    2016-07-19

    There have been frequent cases of civil complaints and disputes in relation to floor impact noises over the years. To solve these issues, a substantial amount of sound resilient material is installed between the concrete slab and the foamed concrete during construction. A new place-type resilient material is made from cement, silica powder, sodium sulfate, expanded-polystyrene, anhydrite, fly ash, and acrylic polymer emulsion resin. Its physical characteristics such as density, compressive strength, dynamic stiffness, and remanent strain are analyzed to assess the acoustic performance of the material. The experimental results showed the density and the dynamic stiffness of the proposed resilient material is increased with proportional to the use of cement and silica powder due to the high contents of the raw materials. The remanent strain, related to the serviceability of a structure, is found to be inversely proportional to the density and strength. The amount of reduction in the heavyweight impact noise is significant in a material with high density, high strength, and low remanent strain. Finally, specimen no. R4, having the reduction level of 3 dB for impact ball and 1 dB for bang machine in the single number quantity level, respectively, is the best product to obtain overall acoustic performance.

  18. Immobilisation Of Spent Ion Exchange Resins Using Portland Cement Blending With Organic Material

    International Nuclear Information System (INIS)

    Zalina Laili; Mohd Abdul Wahab; Nur Azna Mahmud

    2014-01-01

    Immobilisation of spent ion exchange resins (spent resins) using Portland cement blending with organic material for example bio char was investigated. The performance of cement-bio char matrix for immobilisation of spent ion exchange resins was evaluated based on their compression strength and leachability under different experimental conditions. The results showed that the amount of bio char and spent resins loading effect the compressive strength of the waste form. Several factors affecting the leaching behaviour of immobilised spent resins in cement-bio char matrix. (author)

  19. The bond of different post materials to a resin composite cement and a resin composite core material.

    Science.gov (United States)

    Stewardson, D; Shortall, A; Marquis, P

    2012-01-01

    To investigate the bond of endodontic post materials, with and without grit blasting, to a resin composite cement and a core material using push-out bond strength tests. Fiber-reinforced composite (FRC) posts containing carbon (C) or glass (A) fiber and a steel (S) post were cemented into cylinders of polymerized restorative composite without surface treatment (as controls) and after grit blasting for 8, 16, and 32 seconds. Additional steel post samples were sputter-coated with gold before cementation to prevent chemical interaction with the cement. Cylindrical composite cores were bonded to other samples. After sectioning into discs, bond strengths were determined using push-out testing. Profilometry and electron microscopy were used to assess the effect of grit blasting on surface topography. Mean (standard deviation) bond strength values (MPa) for untreated posts to resin cement were 8.41 (2.80) for C, 9.61(1.88) for A, and 19.90 (3.61) for S. Prolonged grit blasting increased bond strength for FRC posts but produced only a minimal increase for S. After 32 seconds, mean values were 20.65 (4.91) for C, 20.41 (2.93) for A, and 22.97 (2.87) for S. Gold-coated steel samples produced the lowest bond strength value, 7.84 (1.40). Mean bond strengths for untreated posts bonded to composite cores were 6.19 (0.95) for C, 13.22 (1.61) for A, and 8.82 (1.18) for S, and after 32 seconds of grit blasting the values were 17.30 (2.02) for C, 26.47 (3.09) for A, and 20.61 (2.67) for S. FRC materials recorded higher roughness values before and after grit blasting than S. With prolonged grit blasting, roughness increased for A and C, but not for S. There was no evidence of significant bonding to untreated FRC posts, but significant bonding occurred between untreated steel posts and the resin cement. Increases in the roughness of FRC samples were material dependent and roughening significantly increased bond strength values (ptested FRC posts is required for effective bonding.

  20. Experiment of forced convection heat transfer using microencapsulated phase-change-material slurries

    International Nuclear Information System (INIS)

    Kubo, Shinji; Akino, Norio; Tanaka, Amane; Nagashima, Akira.

    1997-01-01

    The present study describes an experiment on forced convective heat transfer using a water slurry of Microencapsulated Phase-change-material. A normal paraffin hydrocarbon is microencapsulated by melamine resin, melting point of 28.1degC. The heat transfer coefficient and pressure drop in a circular tube were evaluated. The heat transfer coefficient using the slurry in case with and without phase change were compared to in case of using pure water. (author)

  1. Simulation of the Vacuum Assisted Resin Transfer Molding (VARTM) process and the development of light-weight composite bridging

    Science.gov (United States)

    Robinson, Marc J.

    A continued desire for increased mobility in the aftermath of natural disasters, or on the battlefield, has lead to the need for improved light-weight bridging solutions. This research investigates the development of a carbon/epoxy composite bridging system to meet the needs for light-weight bridging. The research focuses on two main topics. The first topic is that of processing composite structures and the second is the design and testing of these structures. In recent years the Vacuum Assisted Resin Transfer Molding (VARTM) process has become recognized as a low-cost manufacturing alternative for large Fiber Reinforced Polymer (FRP) composite structures for civil, military, and aerospace applications. The success of the VARTM process (complete wet-out) is very sensitive to the resin injection strategy used and the proper placement of flow distribution materials and inlet and vacuum ports. Predicting the flow front pattern, the time required for infusing a part with resin, and the time required to bleed excess resin at the end of filling, is critical to ensure that the part will become completely impregnated and desired fiber volume fractions achieved prior to the resin gelling (initiation of cure). In order to eliminate costly trial and error experiments to determine the optimal infusion strategy, this research presents a simulation model which considers in-plane flow as well as flow through the thickness of the preform. In addition to resin filling, the current model is able to simulate the bleeding of resin at the end of filling to predict the required bleeding time to reach desired fiber volume fractions for the final part. In addition to processing, the second portion of the dissertation investigates the design and testing of composite bridge deck sections which also serve as short-span bridging for gaps up to 4 m in length. The research focuses on the design of a light-weight core material for bridge decking as well as proof loading of short-span bridge

  2. Composite materials based on modified epoxy resin and carbon fiber

    OpenAIRE

    Gonçalez, Viviane; Barcia, Fabio L.; Soares, Bluma G.

    2006-01-01

    Epoxy resin networks have been modified with block copolymer of polybutadiene and bisphenol A diglycidyl ether (DGEBA)-based on epoxy resin. The epoxy resin modified with carboxyl-terminated polybutadiene presented improved impact resistance and outstanding mechanical performance in terms of flexural and tensile properties because of the presence of rubber particles homogeneously dispersed inside the epoxy matrix. This modified system also resulted in an improvement of mechanical properties o...

  3. Color of bulk-fill composite resin restorative materials.

    Science.gov (United States)

    Barutcigil, Çağatay; Barutcigil, Kubilay; Özarslan, Mehmet Mustafa; Dündar, Ayşe; Yilmaz, Burak

    2017-09-28

    To evaluate the color stability of novel bulk-fill composite resins. Color measurements of a nanohybrid composite resin (Z550) and 3 bulk-fill composite resins (BLK, AFX, XTF; n = 45) were performed before polymerization. After polymerization, color measurements were repeated and specimens were immersed in distilled water or red wine, or coffee. Color change [CIEDE2000 (ΔE 00 )] was calculated after 24 h, 1 and 3 weeks. Data were analyzed with Kruskal-Wallis, Mann-Whitney U and Wilcoxon tests (α = 0.05). Color changes observed after polymerization were significant for all groups. Color changes observed in distilled water for Z550 and AFX were significant. Color changes after stored in red wine and coffee were significant for all groups. Bulk-fill composite resin color change increased over time for all groups in red wine and coffee (P composite resin and bulk-fill composite resins. AFX had the highest color change in distilled water. The color of tested bulk-fill composite resins significantly changed after immersion in beverages and over time. Color change observed with the nanohybrid composite resin after 1 week was stable. Clinicians should keep in mind that tested composite resins may change color when exposed to water and significantly change color immediately after they are polymerized. In addition, the color change continues over time should the patient is a coffee and/or red wine consumer. © 2017 Wiley Periodicals, Inc.

  4. Diametral tensile strength of four composite resin core materials with and without centered fiber dowels.

    Science.gov (United States)

    Driessen, Cornel H; Ji, Donatta Y-J; Rizkalla, Amin S; Santos, Gildo C

    2011-01-01

    This study evaluated the diametral tensile strength of composite resin core materials with and without fiber dowels. Eight groups were established (n = 20), four with composite resins and four with fiber dowels. Samples were tested using a universal testing machine and evaluated using scanning electron microscopy. One-way ANOVA and a Tukey B-rank order test (P = 0.05) indicated that the tensile values of two of the four composite resins decreased significantly when their matching fiber dowels were introduced.

  5. Effect of adhesive resin cements on bond strength of ceramic core materials to dentin.

    Science.gov (United States)

    Gundogdu, M; Aladag, L I

    2018-03-01

    The aim of the present study was to evaluate the effects of self-etch and self-adhesive resin cements on the shear bond strength of ceramic core materials bonded to dentin. Extracted, caries-free, human central maxillary incisor teeth were selected, and the vestibule surfaces were cut flat to obtain dentin surfaces. Ceramic core materials (IPS e.max Press and Prettau Zirconia) were luted to the dentin surfaces using three self-etch adhesive systems (Duo-Link, Panavia F 2.0, and RelyX Ultimate Clicker) and two self-adhesive resin systems (RelyX U200 Automix and Maxcem Elite). A shear bond strength test was performed using a universal testing machine. Failure modes were observed under a stereomicroscope, and bonding interfaces between the adhesive resin cements and the teeth were evaluated with a scanning electron microscope. Data were analyzed with Student's t-test and one-way analysis of variance followed by Tukey's test (α = 0.05). The type of adhesive resin cement significantly affected the shear bond strengths of ceramic core materials bonded to dentin (P materials when the specimens were luted with self-adhesive resin cements (P resin cements exhibited better shear bond strength than the self-adhesive resin cements, except for Panavia cement in the IPS e.max Press group. However, shear bond strengths of the self-adhesive resin cements were dependent on the nature of the ceramic core materials.

  6. Solidification of radioactive waste resins using cement mixed with organic material

    International Nuclear Information System (INIS)

    Laili, Zalina; Yasir, Muhamad Samudi; Wahab, Mohd Abdul

    2015-01-01

    Solidification of radioactive waste resins using cement mixed with organic material i.e. biochar is described in this paper. Different percentage of biochar (0%, 5%, 8%, 11%, 14% and 18%) was investigated in this study. The characteristics such as compressive strength and leaching behavior were examined in order to evaluate the performance of solidified radioactive waste resins. The results showed that the amount of biochar affect the compressive strength of the solidified resins. Based on the data obtained for the leaching experiments performed, only one formulation showed the leached of Cs-134 from the solidified radioactive waste resins

  7. Solidification of radioactive waste resins using cement mixed with organic material

    Energy Technology Data Exchange (ETDEWEB)

    Laili, Zalina, E-mail: liena@nm.gov.my [Nuclear Science Programme, School of Applied Physics, Faculty of Science and Technology, Universiti Kebangsaan Malaysia (UKM), Bangi, 43600, Selangor Malaysia (Malaysia); Waste and Environmental Technology Division, Malaysian Nuclear Agency (Nuclear Malaysia), Bangi, 43000 Kajang, Selangor (Malaysia); Yasir, Muhamad Samudi [Nuclear Science Programme, School of Applied Physics, Faculty of Science and Technology, Universiti Kebangsaan Malaysia (UKM), Bangi, 43600, Selangor Malaysia (Malaysia); Wahab, Mohd Abdul [Waste and Environmental Technology Division, Malaysian Nuclear Agency (Nuclear Malaysia), Bangi, 43000 Kajang, Selangor (Malaysia)

    2015-04-29

    Solidification of radioactive waste resins using cement mixed with organic material i.e. biochar is described in this paper. Different percentage of biochar (0%, 5%, 8%, 11%, 14% and 18%) was investigated in this study. The characteristics such as compressive strength and leaching behavior were examined in order to evaluate the performance of solidified radioactive waste resins. The results showed that the amount of biochar affect the compressive strength of the solidified resins. Based on the data obtained for the leaching experiments performed, only one formulation showed the leached of Cs-134 from the solidified radioactive waste resins.

  8. The application of methacrylate resin and the derivation as restorative material of damaged tooth tissue

    Directory of Open Access Journals (Sweden)

    Adioro Soetojo

    2007-12-01

    Full Text Available The application of methacrylate resin and the derivation (composite resin and dentin bonding in clinical conservative dentistry has been widely developed. This material could be used to restore class I-V cavity with good aesthetic due to the compatible color with tooth. Composite resin adhesion hydrophobically in enamel that is due to mechanic retention in the form of resin tags which penetrates into enamel porosity. Meanwhile hydrophilic dentin bonding adhesion due to the chemical reaction between functional groups of amino collagen with carbonyl in dentin bonding forming amide binding. In addition mechanical retention in which dentin bonding penetrating into nano inter fibrilar cavity then polymerized. The success of methacrylate resin adhesion restoration is decided by enamel porosity, wetting character of resin, wetting contact angle, good etching acid, optimal humidity of tooth surface, the accuracy of dentist during filling is done etc.

  9. Synthesis and Characterization of Bio-Oil Phenol Formaldehyde Resin Used to Fabricate Phenolic Based Materials.

    Science.gov (United States)

    Cui, Yong; Hou, Xiaopeng; Wang, Wenliang; Chang, Jianmin

    2017-06-18

    In this study, bio-oil from the fast pyrolysis of renewable biomass was used as the raw material to synthesize bio-oil phenol formaldehyde (BPF) resin-a desirable resin for fabricating phenolic-based material. During the synthesis process, paraformaldehyde was used to achieve the requirement of high solid content and low viscosity. The properties of BPF resins were tested. Results indicated that BPF resin with the bio-oil addition of 20% had good performance on oxygen index and bending strength, indicating that adding bio-oil could modify the fire resistance and brittleness of PF resin. The thermal curing behavior and heat resistance of BPF resins were investigated by differential scanning calorimetry (DSC) and thermal gravimetric analysis (TGA). Results showed that adding bio-oil had an impact on curing characteristics and thermal degradation process of PF resin, but the influence was insignificant when the addition was relatively low. The chemical structure and surface characteristics of BPF resins were determined by Fourier transform infrared (FTIR) spectroscopy and scanning electron microscopy (SEM). The analysis demonstrated that adding bio-oil in the amount of 20% was able to improve the crosslinking degree and form more hydrocarbon chains in PF resin.

  10. Surface Hardness of Resin Cement Polymerized under Different Ceramic Materials

    OpenAIRE

    Kesrak, Pimmada; Leevailoj, Chalermpol

    2012-01-01

    Objectives. To evaluate the surface hardness of two light-cured resin cements polymerized under different ceramic discs. Methods. 40 experimental groups of 2 light-cured resin cement specimens (Variolink Veneer and NX3) were prepared and polymerized under 5 different ceramic discs (IPS e.max Press HT, LT, MO, HO, and Cercon) of 4 thicknesses (0.5, 1.0, 1.5, and 2.0 mm), Those directly activated of both resin cements were used as control. After light activation and 3 7 ∘ C storage in an incuba...

  11. The effect of light curing units, curing time, and veneering materials on resin cement microhardness

    OpenAIRE

    Nurcan Ozakar Ilday; Yusuf Ziya Bayindir; Funda Bayindir; Aysel Gurpinar

    2013-01-01

    Background/purpose: Several factors may affects microhardness of resin cement under veneering materials. The aim of this study was to evaluate the effect of different veneering materials, light-curing units and curing times (20/3, 40/6) on the microhardness of dual-cured resin cement. Materials and methods: We pressed dual-cured resin cement specimens (Clearfil SA cement, 5 mm diameter, 1 mm thick) between two microscopic glass slides covered with transparent polystyrene matrix strips to r...

  12. Honeycomb core material for sandwich construction - with common hexagonal walls bonded by thermoplastic resin and free walls carrying layer of resin and masking agent

    NARCIS (Netherlands)

    Undetermined, U.

    1991-01-01

    Abstract of NL 8902116 (A) In a honeycomb core material for a sandwich construction, the common hexagonal walls are bonded together by a thermoplastic resin, and the free hexagonal walls carry a layer of the same resin and also a masking agent. - A number of plates of raw material are given strips

  13. Flexural Strength of Cold and Heat Cure Acrylic Resins Reinforced with Different Materials.

    Science.gov (United States)

    Heidari, Bijan; Firouz, Farnaz; Izadi, Alireza; Ahmadvand, Shahbaz; Radan, Pegah

    2015-05-01

    Heat-polymerized acrylic resin has been the most commonly used denture base material for over 60 years. However, the mechanical strength of acrylic resin is not adequate for long-term clinical performance of dentures. Consequently, fracture is a common clinical occurrence, which often develops in the midline of the denture base. This study aimed to evaluate the efficacy of cold-cure and heat-cure acrylic resins, reinforced with glass fibers, polyethylene fibers, and metal wire for denture base repair. Ninety specimens were prepared and allocated to nine groups. Ten specimens were considered as controls, and 80 were divided into 8 experimental groups. In the experimental groups, the specimens were sectioned into two halves from the middle, and were then divided into two main groups: one group was repaired with heat cure acrylic resin, and the other with cold cure acrylic resin. Each group was divided into 4 subgroups: unreinforced, reinforced with glass fibers, polyethylene fibers, and metal wire. All specimens were subjected to a 3-point bending test, and the flexural strength was calculated. The group repaired with heat cure acrylic resin and reinforced with glass fiber showed the highest flexural strength; however, the group repaired with cold cure acrylic resin and reinforced with polyethylene fibers had the lowest flexural strength. There was no significant difference between the groups repaired with heat cure and cold cure acrylic resins without reinforcement. Repairing denture base with heat cure acrylic resin, reinforced with glass fibers increases the flexural strength of denture base.

  14. Synthesis and Characterization of Bio-Oil Phenol Formaldehyde Resin Used to Fabricate Phenolic Based Materials

    Directory of Open Access Journals (Sweden)

    Yong Cui

    2017-06-01

    Full Text Available In this study, bio-oil from the fast pyrolysis of renewable biomass was used as the raw material to synthesize bio-oil phenol formaldehyde (BPF resin—a desirable resin for fabricating phenolic-based material. During the synthesis process, paraformaldehyde was used to achieve the requirement of high solid content and low viscosity. The properties of BPF resins were tested. Results indicated that BPF resin with the bio-oil addition of 20% had good performance on oxygen index and bending strength, indicating that adding bio-oil could modify the fire resistance and brittleness of PF resin. The thermal curing behavior and heat resistance of BPF resins were investigated by differential scanning calorimetry (DSC and thermal gravimetric analysis (TGA. Results showed that adding bio-oil had an impact on curing characteristics and thermal degradation process of PF resin, but the influence was insignificant when the addition was relatively low. The chemical structure and surface characteristics of BPF resins were determined by Fourier transform infrared (FTIR spectroscopy and scanning electron microscopy (SEM. The analysis demonstrated that adding bio-oil in the amount of 20% was able to improve the crosslinking degree and form more hydrocarbon chains in PF resin.

  15. The effect of light curing units, curing time, and veneering materials on resin cement microhardness

    Directory of Open Access Journals (Sweden)

    Nurcan Ozakar Ilday

    2013-06-01

    Conclusion: Light-curing units, curing time, and veneering materials are important factors for achieving adequate dual cure resin composite microhardness. High-intensity light and longer curing times resulted in the highest microhardness values.

  16. Investigate the Possibility of Tekcast Methods Used for Casting Polymeric Resin Materials

    Directory of Open Access Journals (Sweden)

    Mäsiar H.

    2014-06-01

    Full Text Available Contribution gives an overview of knowledge about the method of centrifugal casting with orientate on Tekcast system. Company Tekcast Industries has developed a device for centrifugal casting, extending the area of production of castings or prototyping of metal or plastic. Materials suitable for the centrifugal casting with flexible operating parameters may include non-ferrous metal alloy based on zinc or aluminum or non-metallic materials such as polyester resins, polyurethane resins, epoxy resins, waxes and the like. The casting process is particularly suitable for a wide range of commercial castings and decorative objects.

  17. Synthesis and Characterization of Bio-Oil Phenol Formaldehyde Resin Used to Fabricate Phenolic Based Materials

    OpenAIRE

    Cui, Yong; Hou, Xiaopeng; Wang, Wenliang; Chang, Jianmin

    2017-01-01

    In this study, bio-oil from the fast pyrolysis of renewable biomass was used as the raw material to synthesize bio-oil phenol formaldehyde (BPF) resin—a desirable resin for fabricating phenolic-based material. During the synthesis process, paraformaldehyde was used to achieve the requirement of high solid content and low viscosity. The properties of BPF resins were tested. Results indicated that BPF resin with the bio-oil addition of 20% had good performance on oxygen index and bending streng...

  18. Heat transfer in multi-phase materials

    CERN Document Server

    Öchsner, Andreas

    2011-01-01

    This book provides a profound understanding, which physical processes and mechanisms cause the heat transfer in composite and cellular materials. It shows models for all important classes of composite materials and introduces into the latest advances. In three parts, the book covers Composite Materials (Part A), Porous and Cellular Materials (Part B) and the appearance of a conjoint solid phase and fluid aggregate (Part C).

  19. Load transfer characteristics of unilateral distal extension removable partial dentures with polyacetal resin supporting components.

    Science.gov (United States)

    Jiao, T; Chang, T; Caputo, A A

    2009-03-01

    To photoelastically examine load transfer by unilateral distal extension removable partial dentures with supporting and retentive components made of the lower stiffness polyacetal resins. A mandibular photoelastic model, with edentulous space distal to the right second premolar and missing the left first molar, was constructed to determine the load transmission characteristics of a unilateral distal extension base removable partial denture. Individual simulants were used for tooth structure, periodontal ligament, and alveolar bone. Three designs were fabricated: a major connector and clasps made from polyacetal resin, a metal framework as the major connector with polyacetal resin clasp and denture base, and a traditional metal framework I-bar removable partial denture. Simulated posterior bilateral and unilateral occlusal loads were applied to the removable partial dentures. Under bilateral and left side unilateral loading, the highest stress was observed adjacent to the left side posterior teeth with the polyacetal removable partial denture. The lowest stress was seen with the traditional metal framework. Unilateral loads on the right edentulous region produced similar distributed stress under the denture base with all three designs but a somewhat higher intensity with the polyacetal framework. The polyacetal resin removable partial denture concentrated the highest stresses to the abutment and the bone. The traditional metal framework I-bar removable partial denture most equitably distributed force. The hybrid design that combined a metal framework and polyacetal clasp and denture base may be a viable alternative when aesthetics are of primary concern.

  20. Structural health monitoring using fiber optic distributed sensors for vacuum-assisted resin transfer molding

    Science.gov (United States)

    Eum, S. H.; Kageyama, K.; Murayama, H.; Uzawa, K.; Ohsawa, I.; Kanai, M.; Kobayashi, S.; Igawa, H.; Shirai, T.

    2007-12-01

    In this study we implemented manufacturing process and strain monitoring of a composite structure by optical fiber sensors for vacuum-assisted resin transfer molding (VaRTM). Optical fibers with fiber Bragg gratings were embedded into a glass fiber reinforced plastic specimen made by VaRTM and the applicability of structural health monitoring with fiber Bragg grating (FBG) sensors based on optical frequency domain reflectometry (OFDR) was investigated. In this study, long-gage FBGs which are 10 times longer than ordinary FBGs (which are about 10 mm long) were employed for distributed sensing. We can easily map the strain or temperature profile along gratings by OFDR and the spatial resolution of this sensing technique is about 1 mm. The resin flow process in VaRTM could be monitored by measuring the difference in temperature between the resin and preform. Then, the shrinkage of resin could be also monitored during the curing process. The specimen was then subjected to a bending load in a three-point bending test and the strain distributions along the FBGs were measured. From these results we could show the applicability of distributed sensors to quality assurance of a composite structure made by VaRTM and assessment of the structural integrity of in-service composite structures.

  1. Influence of the material for preformed moulds on the polymerization temperature of resin materials for temporary FPDs.

    Science.gov (United States)

    Pott, Philipp-Cornelius; Schmitz-Wätjen, Hans; Stiesch, Meike; Eisenburger, Michael

    2017-08-01

    Temperature increase of 5.5 ℃ can cause damage or necrosis of the pulp. Increasing temperature can be caused not only by mechanical factors, e.g. grinding, but also by exothermic polymerization reactions of resin materials. The aim of this study was to evaluate influences of the form material on the intrapulpal temperature during the polymerization of different self-curing resin materials for temporary restorations. 30 provisonal bridges were made of 5 resin materials: Prevision Temp (Pre), Protemp 4 (Pro), Luxatemp Star (Lux), Structure 3 (Str) and an experimental material (Exp). Moulds made of alginate (A) and of silicone (S) and vacuum formed moulds (V) were used to build 10 bridges each on a special experimental setup. The intrapulpal temperatures of three abutment teeth (a canine, a premolar, and a molar,) were measured during the polymerization every second under isothermal conditions. Comparisons of the maximum temperature (T Max ) and the time until the maximum temperature (t TMax ) were performed using ANOVA and Tukey Test. Using alginate as the mould material resulted in a cooling effect for every resin material. Using the vacuum formed mould, T Max increased significantly compared to alginate ( P material on t TMax . All of the mould materials are suitable for clinical use if the intraoral application time does not exceed the manufacturer's instructions for the resin materials.

  2. Curing efficiency of various resin-based materials polymerized through different ceramic thicknesses and curing time

    Science.gov (United States)

    Lee, Jung-Won; Cha, Hyun-Suk

    2011-01-01

    PURPOSE The aim of this in vitro study was to examine the curing efficiency of various resin-based materials polymerized through ceramic restorations with 3 different thicknesses. Curing efficiency was evaluated by determining the surface microhardness (VHN) of the resin specimens. MATERIALS AND METHODS Four kinds of resin materials were used. Z350 (3M ESPE Filtek™ Z350: A2 Shade), Z250 (3M ESPE Filtek™ Z250: A2 Shade) and Variolink® II (VL: Ivoclar vivadent, base: transparent) either with or without a self-curing catalyst (VLC: Ivoclar vivadent, catalyst: low viscosity/transparent) were filled into the silicone mold (10 mm diameter, 1 mm thick). They were cured through ceramic discs (IPS e.max Press MO-0 ingot ivoclar vivadent, 10 mm diameter, 0.5, 1 and 2 mm thicknesses) by LED light-curing units for 20 and 40 seconds. Vicker's microhardness numbers (VHNs) were measured on the bottom surfaces by a microhardness tester. Data were analyzed using a 3- way analysis of variance (ANOVA) at a significance level of 0.05. RESULTS The thickness of ceramic disc increased, the VHNs of all four resin types were decreased (Plight cured for 40 seconds were significantly higher than that of LED for 20 seconds in all four resin materials (Pcuring time resulted higher VHN values of all resin materials. The use of a catalyst produced a greater hardness with all polymerization methods. Restorative resin materials (Z350, Z250) showed higher VHN values than resin cement materials (VL, VLC). PMID:22053242

  3. Repair bond strength of dual-cured resin composite core buildup materials.

    Science.gov (United States)

    El-Deeb, Heba A; Ghalab, Radwa M; Elsayed Akah, Mai M; Mobarak, Enas H

    2016-03-01

    The reparability of dual-cured resin composite core buildup materials using a light-cured one following one week or three months storage, prior to repair was evaluated. Two different dual-cured resin composites; Cosmecore™ DC automix and Clearfil™ DC automix core buildup materials and a light-cured nanofilled resin composite; Filtek™ Z350 XT were used. Substrate specimens were prepared (n = 12/each substrate material) and stored in artificial saliva at 37 °C either for one week or three months. Afterward, all specimens were ground flat, etched using Scotchbond™ phosphoric acid etchant and received Single Bond Universal adhesive system according to the manufacturers' instructions. The light-cured nanofilled resin composite (Filtek™ Z350 XT) was used as a repair material buildup. To determine the cohesive strength of each solid substrate material, additional specimens from each core material (n = 12) were prepared and stored for the same periods. Five sticks (0.8 ± 0.01 mm(2)) were obtained from each specimen (30 sticks/group) for microtensile bond strength (μTBS) testing. Modes of failure were also determined. Two-way ANOVA revealed a significant effect for the core materials but not for the storage periods or their interaction. After one week, dual-cured resin composite core buildup materials (Cosmecore™ DC and Clearfil™ DC) achieved significantly higher repair μTBS than the light-cured nanofilled resin composite (Filtek™ Z350 XT). However, Clearfil™ DC revealed the highest value, then Cosmecore™ DC and Filtek™ Z350 XT, following storage for 3-month. Repair strength values recovered 64-86% of the cohesive strengths of solid substrate materials. The predominant mode of failure was the mixed type. Dual-cured resin composite core buildup materials revealed acceptable repair bond strength values even after 3-month storage.

  4. Diffusion in composite materials made of thermosetting resins

    International Nuclear Information System (INIS)

    Morin, Bruno.

    1981-03-01

    The embedding process of low and medium level radioactive wastes in thermosetting resins allows their containment in a solid matrix. During storage the risk of circulation of water is possible. The aim of this containment process is to prevent radionuclide migration in environment. Ion migration through membranes of thermosetting resins alone or filler added were measured to evaluate released radioactivity by embedded blocks with time and to compare the different embedding formulas. Water influence on diffusion was taken into account considering that radioactive wastes dispersion is faster in a wet medium than in a dry one [fr

  5. Mechanical properties of resin-ceramic CAD-CAM materials after accelerated aging.

    Science.gov (United States)

    Blackburn, Caleb; Rask, Hailee; Awada, Abdallah

    2017-11-29

    The development of polymer-based computer-aided design and computer-aided manufacturing (CAD-CAM) milling bocks and the limited availability of independent studies on these materials make it pertinent to evaluate changes in their mechanical properties after simulated aging to identify strengths and limitations. The purpose of this in vitro study was to measure the effect of thermocycling on the flexural properties of ceramic, resin, and resin-ceramic CAD-CAM materials. Studied materials included Lava Ultimate Restorative (LVU; 3M ESPE), Enamic (ENA; VITA Zahnfabrik), Vitablocs Mark II (VM2; VITA Zahnfabrik), and Paradigm MZ100 (MZ1; 3M ESPE). Polished 4×1.2×14 mm bars (n=45 per material) were prepared from standard-size milling blocks. The 2 distilled water baths of the thermocycling apparatus were set to 5°C and 55°C, with a specimen immersion time of 15 seconds and transfer time of 4 seconds. Fifteen specimens from each material group were subjected to a 3-point flexural test at 3 different thermocycling intervals: 0 (control), 5000, and 10 000 cycles. The flexural test was performed over a 12-mm span with a crosshead speed of 0.5 mm/min. Data were subjected to multiple analyses of variance and the Tukey HSD post hoc tests (α=.05). Mean flexural strength values for 0, 5000, and 10 000 cycles were 133, 130, and 128 MPa for VM2; 175, 139, and 134 MPa for LVU; 154, 144, and 138 MPa for MZ1; and 149, 136, and 132 MPa for ENA. Mean flexural modulus values were 51, 52, and 54 GPa for VM2; 14, 13, and 13 GPa for LVU; 16, 15, and 15 GPa for MZ1; and 31, 30, and 31 GPa for ENA. Mean modulus of resilience values were 0.17, 0.16, and 0.15 MPa for VM2; 10.1, 0.76, and 0.72 MPa for LVU; 0.77, 0.69, and 0.62 MPa for MZ1; and 0.42, 0.31, and 0.28 MPa for ENA. A significant difference was found among the materials in the mean change of flexural strength (P<.001) and modulus of resilience (P<.05) after thermocycling. No significant difference was found among the

  6. Mechanical and antibacterial properties of benzothiazole-based dental resin materials.

    Science.gov (United States)

    Zhu, Wenbin; Lao, Chonghui; Luo, Shuzhen; Liu, Fang; Huang, Qiting; He, Jingwei; Lin, Zhengmei

    2018-04-01

    A synthesized benzothiazole containing mono-methacrylate monomer BTTMA was incorporated into Bis-GMA/TEGDMA dental resin system with a series of mass concentration from 5 to 30 wt.% as an antibacterial agent. The influence of BTTMA on physicochemical properties of dental resin system, such as double bond conversion (DC), volumetric shrinkage (VS), flexural strength (FS) and modulus (FM), water sorption (WS) and solubility (SL) were investigated. Direct contact testing and agar diffusion testing were used to evaluate the antibacterial activity of BTTMA containing dental resin. The results showed that BTTMA could endow dental resin with significant antibacterial activity when its concentration reached a certain amount (20 wt.%), and the antibacterial activity of BTTMA containing dental resin was mainly attributed to the immobilized BTTMA instead of the unreacted leachable BTTMA. BTTMA had no negative effect on physicochemical properties of dental resin, and even some BTTMA containing dental resins had advantages like higher DC, lower VS and WS when compared with control resin. Therefore, BTTMA could be considered as a suitable antibacterial agent in dental material, but much more researches concerned about biocompatibility should be done in future to prove whether it could be applied in clinic.

  7. Evaluation of Hand Lay-Up and Resin Transfer Molding in Composite Wind Turbine Blade Manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    CAIRNS,DOUGLAS S.; SHRAMSTAD,JON D.

    2000-06-01

    The majority of the wind turbine blade industry currently uses low cost hand lay-up manufacturing techniques to process composite blades. While there are benefits to the hand lay-up process, drawbacks inherent to this process along with advantages of other techniques suggest that better manufacturing alternatives may be available. Resin Transfer Molding (RTM) was identified as a processing alternative and shows promise in addressing the shortcomings of hand lay-up. This report details a comparison of the RTM process to hand lay-up of composite wind turbine blade structures. Several lay-up schedules and critical turbine blade structures were chosen for comparison of their properties resulting from RTM and hand lay-up processing. The geometries investigated were flat plate, thin and thick flanged T-stiffener, I-beam, and root connection joint. It was found that the manufacturing process played an important role in laminate thickness, fiber volume, and weight for the geometries investigated. RTM was found to reduce thickness and weight and increase fiber volumes for all substructures. RTM resulted in tighter material transition radii and eliminated the need for most secondary bonding operations. These results would significantly reduce the weight of wind turbine blades. Hand lay-up was consistently slower in fabrication times for the structures investigated. A comparison of mechanical properties showed no significant differences after employing fiber volume normalization techniques to account for geometry differences resulting from varying fiber volumes. The current root specimen design does not show significant mechanical property differences according to process and exceeds all static and fatigue requirements.

  8. Factors affecting the bond strength of denture base and reline acrylic resins to base metal materials

    Directory of Open Access Journals (Sweden)

    Naomi Tanoue

    2013-07-01

    Full Text Available OBJECTIVE: The shear bond strengths of two hard chairside reline resin materials and an auto-polymerizing denture base resin material to cast Ti and a Co-Cr alloy treated using four conditioning methods were investigated. MATERIAL AND METHODS: Disk specimens (diameter 10 mm and thickness 2.5 mm were cast from pure Ti and Co-Cr alloy. The specimens were wet-ground to a final surface finish of 600 grit, air-dried, and treated with the following bonding systems: 1 air-abraded with 50-70-µm grain alumina (CON; 2 1 + conditioned with a primer, including an acidic phosphonoacetate monomer (MHPA; 3 1 + conditioned with a primer including a diphosphate monomer (MDP; 4 treated with a tribochemical system. Three resin materials were applied to each metal specimen. Shear bond strengths were determined before and after 10,000 thermocycles. RESULTS: The strengths decreased after thermocycling for all combinations. Among the resin materials assessed, the denture base material showed significantly (p<0.05 greater shear bond strengths than the two reline materials, except for the CON condition. After 10,000 thermocycles, the bond strengths of two reline materials decreased to less than 10 MPa for both metals. The bond strengths of the denture base material with MDP were sufficient: 34.56 MPa for cast Ti and 38.30 for Co-Cr alloy. CONCLUSION: Bonding of reline resin materials to metals assessed was clinically insufficient, regardless of metal type, surface treatment, and resin composition. For the relining of metal denture frameworks, a denture base material should be used.

  9. Effect of silver nanoparticles incorporation on viscoelastic properties of acrylic resin denture base material.

    Science.gov (United States)

    Mahross, Hamada Zaki; Baroudi, Kusai

    2015-01-01

    The objective was to investigate the effect of silver nanoparticles (AgNPs) incorporation on viscoelastic properties of acrylic resin denture base material. A total of 20 specimens (60 × 10 × 2 mm) of heat cured acrylic resin were constructed and divided into four groups (five for each), according to the concentration of AgNPs (1%, 2%, and 5% vol.) which incorporated into the liquid of acrylic resin material and one group without additives (control group). The dynamic viscoelastic test for the test specimens was performed using the computerized material testing system. The resulting deflection curves were analyzed by material testing software NEXYGEN MT. The 5% nanoparticles of silver (NAg) had significantly highest mean storage modulus E' and loss tangent Tan δ values followed by 2% NAg (P 0.05). The AgNPs incorporation within the acrylic denture base material can improve its viscoelastic properties.

  10. Cashew nut shell liquid resin used as matrix for compound materials

    International Nuclear Information System (INIS)

    Abreu, Hamilton Ferreira Gomes de; Nogueira, Ricardo Emilio Ferreira Quevedo

    1996-01-01

    Cashew nut shell liquid resin a by product of cashew processing industry is a naturally occurring phenol of low cost and are used in Brazil as fuel in the industrial production of cashew nut or as a structural material when associated with coconut fiber or rice shell. A high measured Tg points to noble applications. This paper presents some properties of LCC resin and concludes that it has good perspectives as a composite matrice to work at elevated temperatures. (author)

  11. Flexural Strength of Cold and Heat Cure Acrylic Resins Reinforced with Different Materials

    Science.gov (United States)

    Heidari, Bijan; Firouz, Farnaz; Izadi, Alireza; Ahmadvand, Shahbaz

    2015-01-01

    Objectives: Heat-polymerized acrylic resin has been the most commonly used denture base material for over 60 years. However, the mechanical strength of acrylic resin is not adequate for long-term clinical performance of dentures. Consequently, fracture is a common clinical occurrence, which often develops in the midline of the denture base. This study aimed to evaluate the efficacy of cold-cure and heat-cure acrylic resins, reinforced with glass fibers, polyethylene fibers, and metal wire for denture base repair. Materials and Methods: Ninety specimens were prepared and allocated to nine groups. Ten specimens were considered as controls, and 80 were divided into 8 experimental groups. In the experimental groups, the specimens were sectioned into two halves from the middle, and were then divided into two main groups: one group was repaired with heat cure acrylic resin, and the other with cold cure acrylic resin. Each group was divided into 4 subgroups: unreinforced, reinforced with glass fibers, polyethylene fibers, and metal wire. All specimens were subjected to a 3-point bending test, and the flexural strength was calculated. Results: The group repaired with heat cure acrylic resin and reinforced with glass fiber showed the highest flexural strength; however, the group repaired with cold cure acrylic resin and reinforced with polyethylene fibers had the lowest flexural strength. There was no significant difference between the groups repaired with heat cure and cold cure acrylic resins without reinforcement. Conclusion: Repairing denture base with heat cure acrylic resin, reinforced with glass fibers increases the flexural strength of denture base. PMID:26877726

  12. Flexural Strength of Cold and Heat Cure Acrylic Resins Reinforced with Different Materials

    Directory of Open Access Journals (Sweden)

    Bijan Heidari

    2015-10-01

    Full Text Available Objectives: Heat-polymerized acrylic resin has been the most commonly used denture base material for over 60 years. However, the mechanical strength of acrylic resin is not adequate for long-term clinical performance of dentures. Consequently, fracture is a com- mon clinical occurrence, which often occurs in the midline of denture base.This study aimed to evaluate the efficacy of cold cure and heat cure acrylic resins, rein- forced with glass fibers, polyethylene fibers, and metal wire for denture base repair.Materials and Methods: Ninety specimens were prepared and allocated to nine groups. Ten specimens were included in the control group, and 80 were allocated to 8 experi- mental groups. In the experimental groups, the specimens were sectioned into two halves from the middle, and were then divided into two main groups: one group was repaired with heat cure acrylic resin, and the other with cold cure acrylic resin. Each group was di- vided into 4 subgroups: unreinforced, reinforced with glass fibers, polyethylene fibers, and metal wire. All specimens were then subjected to a 3-point bending test, and the flexural strength was calculated.Results: The group repaired with heat cure acrylic resin and reinforced with glass fiber showed the highest flexural strength; however, the group repaired with cold cure acrylic resin and reinforced with polyethylene fibers had the lowest flexural strength. There was no significant difference between the groups repaired with heat cure and cold cure acrylic resins without reinforcement.Conclusion: Repairing denture base with heat cure acrylic resin, reinforced with glass fi- bers increases the flexural strength of denture base.

  13. Processing and Properties of Vacuum Assisted Resin Transfer Molded Phenylethynyl Terminated Imide Composites

    Science.gov (United States)

    Cano, Roberto J.; Ghose, Sayata; Watson, Kent A.; Chunchu, Prasad B.; Jensen, Brian J.; Connell, John W.

    2012-01-01

    Polyimide composites are very attractive for applications that require a high strength to weight ratio and thermal stability. Recent work at NASA Langley Research Center (LaRC) has concentrated on developing new polyimide resin systems that can be processed without the use of an autoclave for advanced aerospace applications. Due to their low melt viscosities and long melt stability, certain phenylethynyl terminated imides (PETI) can be processed into composites using high temperature vacuum assisted resin transfer molding (HT-VARTM). VARTM has shown the potential to reduce the manufacturing cost of composite structures. In the current study, two PETI resins, LARC(Trademark) PETI-330 and LARC(Trademark) PETI-9, were infused into carbon fiber preforms at 260 C and cured at temperatures up to 371 C. Photomicrographs of polished cross sections were taken and void contents, determined by acid digestion, were below 4.5%. Mechanical properties including short block compression (SBC), compression after impact (CAI), and open hole compression (OHC) were determined at room temperature, 177 C, and 288 C. Both PETI-9 and PETI-330 composites demonstrated very good retention of mechanical properties at elevated temperatures. SBC and OHC properties after aging for 1000 hours at temperatures up to 288 C were also determined.

  14. Catalysis of deuterium transfer between liquid chloroform and water by anion-exchange resins

    International Nuclear Information System (INIS)

    Symons, E.A.; Bonnett, J.D.

    1985-01-01

    Anion-exchange resins in the hydroxide form have been successfully utilized for catalysis of deuterium transfer between water and liquid chloroform under stirred three-phase slurry conditions. In-solution rate constants for CDCl 3 /H 2 O exchange obtained at 15-35 0 C with liquid chloroform and 0.10 mol/liter NaOH solution under stirred conditions are in good agreement with literature data measured in the absence of bulk chloroform. At 25 0 C the resins tested, Rexyn 201(OH) and Ionac ASB-1P(OH), are ∼25x more effective per mole of - OH present than NaOH when they are used as whole beads. A further improvement is observed if the beads are crushed, but the latter state would be less suitable for commercial-scale application. The solubility of chloroform in the aqueous phase under isotope-exchange conditions was required to calculate the in-solution rate constants for exchange. A method was developed to obtain chloroform solubilities in 0.10 mol/liter NaOH solution and aqueous resin slurries; equilibrated solution samples were treated with 1 mol/liter NaOH to hydrolyze the dissolved CHCl 3 to chloride ion, which was then analyzed by specific ion electrode. 25 references, 2 figures, 1 table

  15. Fabrication of Closed Hollow Bulb Obturator Using Thermoplastic Resin Material

    Directory of Open Access Journals (Sweden)

    Bidhan Shrestha

    2015-01-01

    Full Text Available Purpose. Closed hollow bulb obturators are used for the rehabilitation of postmaxillectomy patients. However, the time consuming process, complexity of fabrication, water leakage, and discoloration are notable disadvantages of this technique. This paper describes a clinical report of fabricating closed hollow bulb obturator using a single flask and one time processing method for an acquired maxillary defect. Hard thermoplastic resin sheet has been used for the fabrication of hollow bulb part of the obturator. Method. After fabrication of master cast conventionally, bulb and lid part of the defect were formed separately and joined by autopolymerizing acrylic resin to form one sized smaller hollow body. During packing procedure, the defect area was loaded with heat polymerizing acrylic resin and then previously fabricated smaller hollow body was adapted over it. The whole area was then loaded with heat cure acrylic. Further processes were carried out conventionally. Conclusion. This technique uses single flask which reduces laboratory time and makes the procedure simple. The thickness of hollow bulb can be controlled and light weight closed hollow bulb prosthesis can be fabricated. It also minimizes the disadvantages of closed hollow bulb obturator such as water leakage, bacterial infection, and discoloration.

  16. Electronically and ionically conductive porous material and method for manufacture of resin wafers therefrom

    Energy Technology Data Exchange (ETDEWEB)

    Lin, YuPo J [Naperville, IL; Henry, Michael P [Batavia, IL; Snyder, Seth W [Lincolnwood, IL

    2008-11-18

    An electrically and ionically conductive porous material including a thermoplastic binder and one or more of anion exchange moieties or cation exchange moieties or mixtures thereof and/or one or more of a protein capture resin and an electrically conductive material. The thermoplastic binder immobilizes the moieties with respect to each other but does not substantially coat the moieties and forms the electrically conductive porous material. A wafer of the material and a method of making the material and wafer are disclosed.

  17. Electronically and ionically conductive porous material and method for manufacture of resin wafers therefrom

    Science.gov (United States)

    Lin, YuPo J [Naperville, IL; Henry, Michael P [Batavia, IL; Snyder, Seth W [Lincolnwood, IL

    2011-07-12

    An electrically and ionically conductive porous material including a thermoplastic binder and one or more of anion exchange moieties or cation exchange moieties or mixtures thereof and/or one or more of a protein capture resin and an electrically conductive material. The thermoplastic binder immobilizes the moieties with respect to each other but does not substantially coat the moieties and forms the electrically conductive porous material. A wafer of the material and a method of making the material and wafer are disclosed.

  18. Nanostructured composites based on carbon nanotubes and epoxy resin for use as radar absorbing materials

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Valdirene Aparecida [Instituto Tecnologico de Aeronautica (ITA), Sao Jose dos Campos, SP (Brazil); Folgueras, Luiza de Castro; Candido, Geraldo Mauricio; Paula, Adriano Luiz de; Rezende, Mirabel Cerqueira, E-mail: mirabelmcr@iae.cta.br [Instituto de Aeronautica e Espaco (IAE), Sao Jose dos Campos, SP (Brazil). Div. de Materiais; Costa, Michelle Leali [Universidade Estadual Paulista Julio de Mesquita Filho (DMT/UNESP), Guaratingueta, SP (Brazil). Dept. de Materiais e Tecnologia

    2013-07-01

    Nanostructured polymer composites have opened up new perspectives for multifunctional materials. In particular, carbon nanotubes (CNTs) present potential applications in order to improve mechanical and electrical performance in composites with aerospace application. The combination of epoxy resin with multi walled carbon nanotubes results in a new functional material with enhanced electromagnetic properties. The objective of this work was the processing of radar absorbing materials based on formulations containing different quantities of carbon nanotubes in an epoxy resin matrix. To reach this objective the adequate concentration of CNTs in the resin matrix was determined. The processed structures were characterized by scanning electron microscopy, rheology, thermal and reflectivity in the frequency range of 8.2 to 12.4 GHz analyses. The microwave attenuation was up to 99.7%, using only 0.5% (w/w) of CNT, showing that these materials present advantages in performance associated with low additive concentrations (author)

  19. Nanostructured composites based on carbon nanotubes and epoxy resin for use as radar absorbing materials

    International Nuclear Information System (INIS)

    Silva, Valdirene Aparecida; Folgueras, Luiza de Castro; Candido, Geraldo Mauricio; Paula, Adriano Luiz de; Rezende, Mirabel Cerqueira; Costa, Michelle Leali

    2013-01-01

    Nanostructured polymer composites have opened up new perspectives for multifunctional materials. In particular, carbon nanotubes (CNTs) present potential applications in order to improve mechanical and electrical performance in composites with aerospace application. The combination of epoxy resin with multi walled carbon nanotubes results in a new functional material with enhanced electromagnetic properties. The objective of this work was the processing of radar absorbing materials based on formulations containing different quantities of carbon nanotubes in an epoxy resin matrix. To reach this objective the adequate concentration of CNTs in the resin matrix was determined. The processed structures were characterized by scanning electron microscopy, rheology, thermal and reflectivity in the frequency range of 8.2 to 12.4 GHz analyses. The microwave attenuation was up to 99.7%, using only 0.5% (w/w) of CNT, showing that these materials present advantages in performance associated with low additive concentrations (author)

  20. A study on the radiopacity of cavity lining materials for posterior composite resin restoration

    International Nuclear Information System (INIS)

    Moon, Joo Hoon; Choi, Eui Hwan

    2000-01-01

    The aim of this study was to determine the relative radiopacities of cavity lining materials (Resin-modified Glass Ionomer cement, Compomer and Flowable resin) for posterior composite resin restoration. Resin-modified glass ionomer cement (Fuji II LC, Vitrebond (TM)), Compomers (Dyract , Compoglass, F2000, Dyract(R) flow Compoglass Flow) and Flowable resins (Tetric (R) flow, Aeliteflo (TM) Revolution (TM)) were used. Five specimens of 5 mm in diameter and 2 mm thick were fabricated with each material. Human molars were horizontally sectioned 2 mm thick to include both enamel and dentin. The radiopacities of enamel, dentin, cavity lining materials, aluminum step wedge were obtained from conventional radiograph and NIH image program. All the tested lining materials showed levels of radiopacity the same as or greater than that of dentin. All compomer tested (Dyract (R), Compoglass, F2000, Dyract (R) flow, Compoglass Flow) and Vitrebond (TM), Tetric (R) flow were more radiopaque than enamel. The radiopacities of Fuji II LC and Revolution (TM) were between enamel and dentin and resin-modified glass ionomer cement, Compomer and Tetric (R) flow were greater than those of Revolution (TM), Aeliteflo (TM) or dentin. The level of radiopacity of the tested materials was variable; those with low radiopacity should be avoided in class II restorations, where a clear determination of recurrent caries by the examining clinician could be compromised. Clinician should be able to distinguish these cavity lining materials radiographically from recurrent decay, voids, gaps, or other defects that lead to clinical failure. Utilization of materials ranked more radiopaque than enamel would enable clinicians to distinguish the lining material from tooth structure.

  1. A study on the radiopacity of cavity lining materials for posterior composite resin restoration

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Joo Hoon [Dept. of Oral and Maxillofacial Radiology, College of Dentistry, Chosun University, Kwangju (Korea, Republic of); Choi, Eui Hwan [Dept. of Conservative Dentistry, College of Dentistry, Chosun University, Kwangju (Korea, Republic of)

    2000-12-15

    The aim of this study was to determine the relative radiopacities of cavity lining materials (Resin-modified Glass Ionomer cement, Compomer and Flowable resin) for posterior composite resin restoration. Resin-modified glass ionomer cement (Fuji II LC, Vitrebond (TM)), Compomers (Dyract , Compoglass, F2000, Dyract(R) flow Compoglass Flow) and Flowable resins (Tetric (R) flow, Aeliteflo (TM) Revolution (TM)) were used. Five specimens of 5 mm in diameter and 2 mm thick were fabricated with each material. Human molars were horizontally sectioned 2 mm thick to include both enamel and dentin. The radiopacities of enamel, dentin, cavity lining materials, aluminum step wedge were obtained from conventional radiograph and NIH image program. All the tested lining materials showed levels of radiopacity the same as or greater than that of dentin. All compomer tested (Dyract (R), Compoglass, F2000, Dyract (R) flow, Compoglass Flow) and Vitrebond (TM), Tetric (R) flow were more radiopaque than enamel. The radiopacities of Fuji II LC and Revolution (TM) were between enamel and dentin and resin-modified glass ionomer cement, Compomer and Tetric (R) flow were greater than those of Revolution (TM), Aeliteflo (TM) or dentin. The level of radiopacity of the tested materials was variable; those with low radiopacity should be avoided in class II restorations, where a clear determination of recurrent caries by the examining clinician could be compromised. Clinician should be able to distinguish these cavity lining materials radiographically from recurrent decay, voids, gaps, or other defects that lead to clinical failure. Utilization of materials ranked more radiopaque than enamel would enable clinicians to distinguish the lining material from tooth structure.

  2. Investigation into the Depth of Cure of Resin-Modified Glass-Ionomer Restorative Materials

    Science.gov (United States)

    2006-08-01

    glass - ionomer restorative dental materials. Samples of different thicknesses using...attempt at delineating the depth of cure of resin-modified glass - ionomer restorative dental materials. Samples of different thicknesses using Vitremer... glass ionomers liners. Dent Mater 1993:9:198-203. 16. Culbertson BM. Glass - ionomer dental restoratives . Prog Polym Sci 2001 ;26:577-604. 17. Fuji II

  3. A long-term laboratory test on staining susceptibility of esthetic composite resin materials

    NARCIS (Netherlands)

    Ardu, S.; Braut, V.; Gutemberg, D.; Krejci, I.; Dietschi, D.; Feilzer, A.J.

    2010-01-01

    Objective: To evaluate the color stability of composite resin types designed for esthetic anterior restorations when continuously exposed to various staining agents. Method and Materials: Thirty-six disk-shaped specimens were made of each of 12 composite materials (1 microfilled and 11 hybrid

  4. Effect of polishing systems on stain susceptibility and surface roughness of nanocomposite resin material.

    Science.gov (United States)

    Barakah, Haifa M; Taher, Nadia M

    2014-09-01

    Different polishing systems vary in their effect on reducing surface roughness and stain susceptibility of dental composite resin materials. The purpose of this study was to compare the effect of 3 polishing systems on the stain susceptibility and surface roughness of 2 nanocomposite resins and a microhybrid composite resin. Forty-five disks (2×10 mm) each were fabricated of 2 nanocomposite resins (Filtek Supreme XT and Tetric EvoCeram) and 1 microhybrid composite resin (Z250). Both sides of the disks were wet finished, and 1 side was polished with PoGo, Astropol, or Hi-Shine (n=5). Unpolished surfaces served as controls. The average roughness (Ra, μm) was measured with a profilometer, and the baseline color was recorded with a spectrophotometer. All specimens were incubated while soaking in a staining solution of coffee, green tea, and berry juice for 3 weeks. The color was recorded again, and the data were analyzed with 2-way ANOVA at α=.05 and Tukey multiple comparison tests. All polishing systems improved the staining resistance of Filtek Supreme XT and Z250 but did not affect that of Tetric EvoCeram. The surface color of Filtek Supreme XT was changed significantly and was the smoothest after polishing with PoGo, whereas Hi-Shine produced significantly rougher surfaces but with the lowest color change. Hi-Shine produced the highest color change in Z250. The surface roughness did not differ significantly between the other polishing systems. Tetric EvoCeram showed no significant differences in color change or surface roughness. Staining susceptibility and surface roughness depend mainly on material composition and on the polishing procedures. Polishing improves the staining resistance of composite resins. Nanocomposite resins did not exhibit better staining resistance or surface roughness than microhybrid composite resin. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  5. Experimental Investigation on the Specific Heat of Carbonized Phenolic Resin-Based Ablative Materials

    Science.gov (United States)

    Zhao, Te; Ye, Hong; Zhang, Lisong; Cai, Qilin

    2017-10-01

    As typical phenolic resin-based ablative materials, the high silica/phenolic and carbon/phenolic composites are widely used in aerospace field. The specific heat of the carbonized ablators after ablation is an important thermophysical parameter in the process of heat transfer, but it is rarely reported. In this investigation, the carbonized samples of the high silica/phenolic and carbon/phenolic were obtained through carbonization experiments, and the specific heat of the carbonized samples was determined by a 3D DSC from 150 °C to 970 °C. Structural and compositional characterizations were performed to determine the mass fractions of the fiber and the carbonized product of phenolic which are the two constituents of the carbonized samples, while the specific heat of each constituent was also measured by 3D DSC. The masses of the carbonized samples were reduced when heated to a high temperature in the specific heat measurements, due to the thermal degradation of the carbonized product of phenolic resin in the carbonized samples. The raw experimental specific heat of the two carbonized samples and the carbonized product of phenolic resin was modified according to the quality changes of the carbonized samples presented by TGA results. Based on the mass fraction and the specific heat of each constituent, a weighted average method was adopted to obtain the calculated results of the carbonized samples. Due to the unconsolidated property of the fiber samples which impacts the reliability of the DSC measurement, there is a certain deviation between the experimental and calculated results of the carbonized samples. Considering the similarity of composition and structure, the data of quartz glass and graphite were used to substitute the specific heat of the high silica fiber and carbon fiber, respectively, resulting in better agreements with the experimental ones. Furthermore, the accurate specific heat of the high silica fiber and carbon fiber bundles was obtained by

  6. Physical Property Investigation of Two Recently Marketed Resin Composite Restorative Materials

    Science.gov (United States)

    2015-06-18

    Huysmans  MCDNJM.  12-­‐year   Survival  of   Composite  vs.   Amalgam  Restorations.  J  Dent  Res  2010;  89:1063-­‐   1067...Marketed Resin Composite Restorative Materials 7. Intended publication/meeting: International Association of Dental Research Annual Meeting 8...Marketed Resin Composite Restorative Materials Major Marcus P. Kropf APPROVED; Colo71 Howard W. Roberts Date APPROVED: Col Drew W. Fallis Dean, Air

  7. The influence of powder liquid ratio on the flexural strength of fibre reinforced acrylic resin material.

    Science.gov (United States)

    Geerts, G A V M; du Rand, M

    2009-04-01

    Often the powder liquid (P/L) ratio of polymethyl methacrylate (PMMA) resins is changed to modify the handling properties of the material. While it is known that this may influence the mechanical properties of unreinforced PMMA resin, little is known about its effect on fibre reinforced resin. The purpose of this study was to determine how different P/L ratios influence the flexural strength (FS) of a glass fibre reinforced autopolymerizing PMMA resin used for fabricating fixed partial dentures. Two main groups of PMMA resin, 1 unreinforced and 1 reinforced with glass fibre, had 3 subgroups (n=21) each representing a different P/L ratio. The manufacturer's recommended ratio served as control. The specimens were prepared for a 3-point bending test. Using a universal testing machine, maximum force was recorded and the FS was calculated. Median FS values were compared by means of non-parametric analysis of variance (Kruskal-Wallis). A p-value of less than 0.05 was considered significant. FS values of all reinforced subgroups were significantly higher than the values of the unreinforced subgroups (p0.05). Within the reinforced group there was a significant difference between the control group, which had a higher median FS value than the two other subgroups (presin with glass fibre, it is important to use the recommended P/L ratio. For unreinforced PMMA resin the P/L ratio can be changed within limits without adverse effects on the FS.

  8. Aspects of bonding between resin luting cements and glass ceramic materials.

    Science.gov (United States)

    Tian, Tian; Tsoi, James Kit-Hon; Matinlinna, Jukka P; Burrow, Michael F

    2014-07-01

    The bonding interface of glass ceramics and resin luting cements plays an important role in the long-term durability of ceramic restorations. The purpose of this systematic review is to discuss the various factors involved with the bond between glass ceramics and resin luting cements. An electronic Pubmed, Medline and Embase search was conducted to obtain laboratory studies on resin-ceramic bonding published in English and Chinese between 1972 and 2012. Eighty-three articles were included in this review. Various factors that have a possible impact on the bond between glass ceramics and resin cements were discussed, including ceramic type, ceramic crystal structure, resin luting cements, light curing, surface treatments, and laboratory test methodology. Resin-ceramic bonding has been improved substantially in the past few years. Hydrofluoric acid (HF) etching followed by silanizaiton has become the most widely accepted surface treatment for glass ceramics. However, further studies need to be undertaken to improve surface preparations without HF because of its toxicity. Laboratory test methods are also required to better simulate the actual oral environment for more clinically compatible testing. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  9. Studi Eksperimental Laju Keausan Material Gigi Tiruan dari Resin Akrilik Berpenguat Fiberglass dengan Variasi Susunan Serat Penguat

    OpenAIRE

    Kristasari, Prastika; Kaelani, Yusuf

    2016-01-01

    Resin akrilik adalah salah satu material yang mulai banyak digunakan sebagai salah satu material untuk pembuatan gigi tiruan. Penelitian sebelumnya tentang analisis pengujian laju keausan resin akrilik berpenguat serat pada dental prosthesis pada kondisi dry sliding menunjukkan hasil nilai laju keausan berkurang dengan adanya penambahan serat[1]. Saat ini belum ada kajian mengenai laju keausan resin akrilik berpenguat serat pada kondisi wet sliding dengan variasi pola susunan serat yang berbe...

  10. Development of a new neutron shielding material, TN trademark Resin Vyal for transport/storage casks for radioactive materials

    International Nuclear Information System (INIS)

    Abadie, P.

    2004-01-01

    TN trademark Resin Vyal, a patent pending composite, is a new neutron shielding material developed by COGEMA LOGISTICS for transport/storage casks of radioactive materials (spent fuel, reprocessed fuel,..). This material is composed of a thermosetting resin (vinylester resin in solution of styrene) and two mineral fillers (alumine hydrate and zinc borate). Its shielding ability for neutron radiation is related to a high hydrogen content (for slowing down neutrons) and a high boron content (for absorbing neutrons). Source of hydrogen is organic matrix (resin) and alumine hydrate; source of boron is zinc borate. Atomic concentrations are equal to 5.10 22 at/cm 3 for hydrogen and 9.10 20 at/cm 3 for boron. Due to the flame retardant character of components, the final material has a good fire resistance (it is auto-extinguishable). Its density is equal to 1,8. The manufacturing process of these material is easy: it consists in mixing the fillers and pouring in-situ (in cask); so, the curing of this composite, which leads to a three-dimensional structure, takes place at ambient temperature. Temperature resistance of this material was evaluated by performing exposition tests of samples at different temperatures (150 C to 170 C). According to tests results, its maximal temperature of use was confirmed equal to 160 C

  11. Criteria for onsite transfers of radioactive material

    International Nuclear Information System (INIS)

    Opperman, E.K.; Jackson, E.J.; Eggers, A.G.

    1992-01-01

    A general description of the requirements for making onsite transfers of radioactive material is provided in Chapter 2, along with the required sequencey of activities. Various criteria for package use are identified in Chapters 3-13. These criteria provide protection against undue radiation exposure. Package shielding, containment, and surface contamination requirements are established. Criteria for providing criticality safety are enumerated in Chapter 6. Criteria for providing hazards information are established in Chapter 13. A glossary is provided

  12. Laser induced forward transfer of soft materials

    International Nuclear Information System (INIS)

    Palla-Papavlu, A; Dinca, V; Luculescu, C; Dinescu, M; Shaw-Stewart, J; Lippert, T; Nagel, M

    2010-01-01

    A strong research effort is presently aimed at patterning methodologies for obtaining controlled defined micrometric polymeric structures for a wide range of applications, including electronics, optoelectronics, sensors, medicine etc. Lasers have been identified as appropriate tools for processing of different materials, such as ceramics and metals, but also for soft, easily damageable materials (biological compounds and polymers). In this work we study the dynamics of laser induced forward transfer (LIFT) with a gap between the donor and the receiver substrates, which is the basis for possible applications that require multilayer depositions with high spatial resolution

  13. Effect of 180 days of water storage on the transverse strength of acetal resin denture base material.

    Science.gov (United States)

    Arikan, Ayla; Ozkan, Yasemin Kulak; Arda, Tugberk; Akalin, Buket

    2010-01-01

    Acetal resin has been used as an alternative denture base and clasp material since 1986. The manufacturers claim that acetal resin has superior physical properties when compared to conventional denture base acrylic resins. Limited information is available about transverse strengths of acetal resin. The purpose of this investigation was to compare transverse strengths of pink and white acetal resins to transverse strengths of conventional heat-polymerized polymethylmethacrylate (PMMA) resin in increasing durations of water storage. A transverse strength test was performed in accordance with International Standards Organization (ISO) specification No 1567. Twenty 65 x 10 x 2.5 mm(3) specimens of each resin were prepared; five specimens of each resin group were subjected to three-point bending test after 50 hours, 30 days, 60 days, and 180 days of water storage in distilled water at 37 degrees C. Experimental groups' transverse strengths were compared by three-way ANOVA and Duncan's multiple range tests. Transverse strength of PMMA denture base material was found to be in accordance with the requirements of ISO specification No 1567. Transverse strengths of white and pink acetal resin could not be calculated in this study, as white and pink acetal resin specimens did not break at the maximum applied force in the three-point bending test. Flexural strength of acetal resin was found to be within the ISO specification limits. As the water storage time increased, the deflection values of PMMA showed no significant difference (p > 0.05). Both the white and pink acetal resin showed significant increase in deflection as the water storage time was increased from 50 hours to 180 days (p resin suffered from permanent deformation, but did not break in the three-point bending test. Acetal resin showed significant increase in deflection as the water storage time was increased from 50 hours to 180 days. All materials tested demonstrated deflection values in compliance with ISO

  14. Development of highly effective neutron shielding material made of phenol-novolac type epoxy resin

    International Nuclear Information System (INIS)

    Cho, Soo Haeng; Jeong, Myeong Soo; Hong, Sun Seok; Lee, Won Kyoung; Kim, Ik Soo; Shin, Young Joon; Do, Jae Bum; Ro, Seung Gy; Oh, Seok Jin

    1998-06-01

    Because the exposure to radiation in the nuclear facilities can be fatal to human, it is important to reduce the radiation dose level to a tolerable level. The purpose of this study is to develop highly effective neutron shielding materials for the shipping and storage cask of radioactive materials or in the nuclear/radiation facilities. On this study, we developed epoxy resin based neutron shielding materials and their various material properties, including neutron shielding ability, fire resistance, combustion characteristics, radiation resistance, thermal and mechanical properties were evaluated experimentally. Especially we developed phenol-novolac type epoxy resin based neutron shielding materials and their characteristics were also evaluated. (author). 22 refs., 11 tabs., 21 figs

  15. Radiopacity of bulk fill flowable resin composite materials | Yildirim ...

    African Journals Online (AJOL)

    Objectives: The purpose of this study was to evaluate the radiopacity of currently marketed bulk fill flowable dental composite materials (Beautifil Bulk Flowable, SDR Flow, Filtek Bulk Fill Flow, and x‑tra Base Bulk Fill). Materials and Methods: Six specimens of each material with a thickness of 1 mm were prepared, and ...

  16. Radiopacity of bulk fill flowable resin composite materials

    African Journals Online (AJOL)

    2015-08-23

    Aug 23, 2015 ... Objectives: The purpose of this study was to evaluate the radiopacity of currently marketed bulk fill flowable dental composite materials (Beautifil Bulk Flowable, SDR Flow, Filtek Bulk Fill Flow, and x‑tra Base Bulk Fill). Materials and Methods: Six specimens of each material with a thickness of 1 mm were ...

  17. Preliminary guidelines and recommendations for the development of material and process specifications for carbon fiber-reinforced liquid resin molded materials.

    Science.gov (United States)

    2007-05-01

    This document recommends guidance and criteria for the development of material and process specifications and material acceptance documents for liquid resins and continuous carbon fiber reinforcement materials used in liquid molding processes to manu...

  18. Resin bond to indirect composite and new ceramic/polymer materials: a review of the literature.

    Science.gov (United States)

    Spitznagel, Frank A; Horvath, Sebastian D; Guess, Petra C; Blatz, Markus B

    2014-01-01

    Resin bonding is essential for clinical longevity of indirect restorations. Especially in light of the increasing popularity of computer-aided design/computer-aided manufacturing-fabricated indirect restorations, there is a need to assess optimal bonding protocols for new ceramic/polymer materials and indirect composites. The aim of this article was to review and assess the current scientific evidence on the resin bond to indirect composite and new ceramic/polymer materials. An electronic PubMed database search was conducted from 1966 to September 2013 for in vitro studies pertaining the resin bond to indirect composite and new ceramic/polymer materials. The search revealed 198 titles. Full-text screening was carried out for 43 studies, yielding 18 relevant articles that complied with inclusion criteria. No relevant studies could be identified regarding new ceramic/polymer materials. Most common surface treatments are aluminum-oxide air-abrasion, silane treatment, and hydrofluoric acid-etching for indirect composite restoration. Self-adhesive cements achieve lower bond strengths in comparison with etch-and-rinse systems. Thermocycling has a greater impact on bonding behavior than water storage. Air-particle abrasion and additional silane treatment should be applied to enhance the resin bond to laboratory-processed composites. However, there is an urgent need for in vitro studies that evaluate the bond strength to new ceramic/polymer materials. This article reviews the available dental literature on resin bond of laboratory composites and gives scientifically based guidance for their successful placement. Furthermore, this review demonstrated that future research for new ceramic/polymer materials is required. © 2014 Wiley Periodicals, Inc.

  19. Performance of three resin-based materials for treating uranium-contaminated groundwater within a PRB

    International Nuclear Information System (INIS)

    Barton, Catherine S.; Stewart, Douglas I.; Morris, Katherine; Bryant, David E.

    2004-01-01

    Three materials that are designed to treat uranium-contaminated water were investigated. These are a cation exchange resin, IRN 77; an anion exchange resin, Varion AP; and a recently developed material called PANSIL (quartz sand coated with 2% amidoxime resin by weight). The reaction rate, capacity, and effective pH range of the three materials are reported. The capacity and conditional distribution coefficient in neutral, uranyl-contaminated synthetic groundwater containing carbonate are also reported. The suitability of each material for treating uranium-contaminated groundwater using a permeable reactive barrier (PRB) approach is then discussed. All three materials react rapidly in the pH range 5-7, reaching equilibrium in less than 4 h at ∼23 deg. C. The unconditioned cation exchange resin removed 8 g UO 2 2+ per kg of resin from neutral synthetic groundwater containing 30 mg/l of UO 2 2+ , but a lower capacity is anticipated in groundwater with either higher ionic strength or lower UO 2 2+ concentrations. It operates by first acidifying the solution, then sorbing UO 2 2+ , and can release UO 2 2+ when its buffering capacity has been exhausted. The anion exchange resin is very effective at removing anionic uranyl carbonate species from solutions with a pH above 5, with good specificity. Up to 50 g/kg of uranium is removed from contaminated groundwater at neutral pH. PANSIL is effective at sequestering cationic and neutral uranyl species from solutions in the pH range 4.5-7.5, with very good specificity. The capacity of PANSIL is pH-dependent, increasing from about 0.4 g/kg at pH 4.5, to about 1 g/kg at pH 6, and 1.5 g/kg around pH 7.5. In neutral groundwater containing carbonate, both the anion exchange resin and PANSIL exhibit conditional distribution coefficients exceeding 1470 ml/g, which is about an order of magnitude higher than comparable reactive barrier materials reported in the literature

  20. Two-photon polymerization of an epoxy-acrylate resin material system

    International Nuclear Information System (INIS)

    Winfield, R.J.; O'Brien, S.

    2011-01-01

    Improved material systems are of great interest in the development of two-photon polymerization techniques for the fabrication of three dimensional micro- and nano-structures. The properties of the photosensitive resin are important in the realisation of structures with submicron dimensions. In this study investigation of a custom organic resin, cross-linked by a two-photon induced process, using a femtosecond Ti:sapphire laser, is described. A structural, optical and mechanical analysis of the optimised material is presented. The influence of both material system and laser processing parameters on achievable micro-structure and size is presented as are representative structures. Parameters include: laser power, photo-initiator concentration and material composition.

  1. Study on polyethylene glycol/epoxy resin composite as a form-stable phase change material

    International Nuclear Information System (INIS)

    Fang Yutang; Kang Huiying; Wang Weilong; Liu Hong; Gao Xuenong

    2010-01-01

    Form-stable polyethylene glycol (PEG)/epoxy resin (EP) composite as a novel phase change material (PCM) was prepared using casting molding method. In this new material, PEG acts as the latent heat storage material and EP polymer serves as the supporting material, which provides structural strength and prevents the leakage of the melted PEG. The structure and morphology of the novel composite were observed using Fourier transformation infrared spectroscope (FTIR) and scanning electronic microscope (SEM). The thermo-mechanical property and transition behavior were characterized by polarizing optical microscope (POM), static thermo-mechanical analysis (TMA) and differential scanning calorimeter (DSC). The experimental results show that, as a result of the physical tangled function of the epoxy resin carrier to the PEG segment, the composite macroscopically presents the solid-solid phase change characteristic.

  2. Shear bond strength of four resin cements used to lute ceramic core material to human dentin.

    Science.gov (United States)

    Altintas, Subutayhan; Eldeniz, Ayçe Unverdi; Usumez, Aslihan

    2008-12-01

    This study evaluated the effect of four resin cements on the shear bond strength of a ceramic core material to dentin. One hundred twenty molar teeth were embedded in a self-curing acrylic resin. The occlusal third of the crowns were sectioned under water cooling. All specimens were randomly divided into four groups of 30 teeth each according to the resin cement used. One hundred twenty cylindrical-shaped, 2.7-mm wide, 3-mm high ceramic core materials were heat-pressed. The core cylinders were then luted with one of the four resin systems to dentin (Super-Bond C&B, Chemiace II, Variolink II, and Panavia F). Half of the specimens (n = 15) were tested after 24 hours; the other half (n = 15) were stored in distilled water at 37 degrees C for 1 day and then thermocycled 1000 times between 5 degrees C and 55 degrees C prior to testing. Shear bond strength of each specimen was measured using a universal testing machine at a crosshead speed of 1 mm/min. The bond strength values were calculated in MPa, and the results were statistically analyzed using a two-way analysis of variance (ANOVA) and Tukey HSD tests. The shear bond strength varied significantly depending on the resin cement used (p 0.05). Significant interactions were present between resin cement and thermocycling (p 0.05). The increase in the shear bond strength values in the Panavia F (4.5 +/- 0.7 MPa) and Variolink II (5.5 +/- 2.1 MPa) groups after thermocycling was also not statistically significant (p > 0.05). Variolink II and Panavia F systems showed higher shear bond strength values than Chemiace II and Super-Bond C&B. They can be recommended for luting ceramic cores to dentin surfaces.

  3. An Analytical Vacuum-Assisted Resin Transfer Molding (VARTM) Flow Model

    National Research Council Canada - National Science Library

    Fink, Bruce

    2000-01-01

    .... The analytical solution presented here provides insight into the scaling laws governing fill times and resin inlet placement as a function of the properties of the preform, distribution media, and resin...

  4. Radiometric determinations of linear mass, resin levels and density of composite materials

    International Nuclear Information System (INIS)

    Boutaine, J.L.; Pintena, J.; Tanguy, J.C.

    1978-01-01

    A description is given of the principle, characteristics and performances of a gamma back-scattering gauge developed in cooperation between the CEA and SNPE. This instrument allows for on-line inspection of the linear mass and resin level of strips of composite materials whilst being produced. The industrial application involved boron, carbon and 'Kevlar' fibres. The performance of beta and gamma transmission gauges are also given for inspecting the density of panels and dense composite materials [fr

  5. In vitro evaluation of the bond strength of composite resin foundation materials to dentin.

    Science.gov (United States)

    Al-Ansari, Asim; Al-Harbi, Fahad; Baba, Nadim Z

    2015-10-01

    Achieving adequate bonding of composite resin foundation materials to dentin can be a challenge. Bonding can be affected by the type of bonding material and method used. The purpose of this in vitro study was to test the bond strengths of selected dual-polymerizing composite resin foundation materials to dentin using light, chemical, or dual-polymerized adhesive systems. Eighty freshly extracted human third molars were sectioned vertically into mesial and distal halves and embedded in acrylic resin using a copper cylinder. Specimens were divided into 16 groups. Each group received a resin foundation that was bonded to dentin according to each manufacturer's instructions. All tested foundations were dual polymerized except Tetric Ceram, which was light polymerized. BisCore, Build-it, CompCore, CoreRestore, and FluoroCore resin foundation materials were bonded to dentin with the use of the corresponding adhesives in 3 different bonding methods: adhesive was light polymerized; adhesive was chemically polymerized; and adhesive was dual polymerized. Each specimen was seated in a custom shear test device, and a load was applied with the descending rod of the jig from a mechanical testing machine with a perpendicular force to the dentin-adhesive interface. Statistical analysis was performed using 2-way ANOVA and post hoc pairwise comparison with Tukey test when statistically significant differences were found (α=.05). Resin foundation materials bonded to dentin with light-polymerized adhesives produced significantly higher bond strengths than when bonded with chemically or dual-polymerized adhesives. No significant difference was found between the single-component and multiple-components adhesives used with Tetric Ceram and BisCore foundations (P=.083). However, BisCore used with All-Bond 2 adhesive (multiple components) produced significantly lower bond strengths than when used with One-Step (P=.024). Adhesive failure was the most common failure location. Cohesive

  6. In vitro wear of resin-based materials--simultaneous corrosive and abrasive wear.

    Science.gov (United States)

    Correr, Gisele Maria; Bruschi Alonso, Roberta Caroline; Correr Sobrinho, Lourenço; Puppin-Rontani, Regina Maria; Ferracane, Jack Liborio

    2006-07-01

    The aim of this study was to evaluate the wear of resin-based materials caused by the association of abrasive and corrosive processes. Twenty specimens were prepared for each material, cast in epoxy in acrylic rings, polished, and profiled with an MTS 3D Profiler. Antagonists were made from deciduous molars. Specimens were distributed into eight groups (n = 10), according to the material (Filtek Supreme, Point 4, Dyract AP, and Fuji II LC) and the type of slurry (neutral and acidic), and then cycled 100,000 times in the OHSU oral wear simulator. The specimens were cleaned and reprofiled. Volume loss and maximum depth were determined. ANOVA and Tukey's test were used for data analysis (p wear facet on the antagonist was also measured. Composites displayed less wear than the compomer and the resin-modified glass ionomer. Significant differences also were found for cusp wear, with a significant positive correlation shown between cusp and material wear. The acidic slurry significantly increased the wear of the materials compared to the neutral slurry. Exposure to acidic slurry accelerated the wear of resin-based materials.

  7. Comparative evaluation of few physical properties of epoxy resin, resin-modified gypsum and conventional type IV gypsum die materials: an in vitro study.

    Science.gov (United States)

    Gujjarlapudi, Manmohan Choudary; Reddy, S Varalakshmi; Madineni, Praveen Kumar; Ealla, Kranti Kiran Reddy; Nunna, Venkata Narayana; Manne, Sanjay Dutt

    2012-01-01

    To compare and evaluate few physical properties of epoxy resin, resin-modified gypsum and conventional type-IV gypsum die material. In the present study, dimensional accuracy, surface detail reproduction and transverse strength of three die materials like epoxy resin (Diemet-E), resin-modified gypsum (Synarock) and conventional type-IV gypsum (Ultrarock) are analyzed. For dimensional accuracy, master die (Bailey's die) is used and calibrations were made with digital microscope. For surface detail reproduction and transverse strength, rectangular stainless steel master die (Duke's die) was used and calibrations were made with Toolmaker's microscope and Instron universal testing machine respectively. One-way analysis of variance (ANOVA) was performed on the means and standard deviation for groups of each test. The results of the study showed statistically significant difference among these materials in dimensional accuracy, surface detail reproduction and transverse strength. Epoxy resin exhibited superiority in dimensional accuracy, surface detail reproduction and transverse strength and is nearest to the standards of accurate die material.

  8. Effectiveness of resin-based materials against erosive and abrasive enamel wear.

    Science.gov (United States)

    Zhao, Xiaoyi; Pan, Jie; Zhang, Songmei; Malmstrom, Hans S; Ren, Yan-Fang

    2017-01-01

    The objective of this study was to test the effectiveness of resin-based materials against erosive enamel wear under erosive and abrasive challenges by orange juice and tooth brushing. Fifty enamel specimens from third molars were assigned to five groups: ICON resin infiltration with no etching (ICON-NE), ICON resin infiltration with 15 % HCl etching (ICON-AE), Seal & Protect sealant (S&P), Tetric EvoFlow (TEF), and control. Erosive lesions were first created on enamel, then treated with resin-based materials. Erosive and abrasive challenges by orange juice and tooth brushing were repeated after treatments. Erosive wear of the treated areas was measured with 3D scanning microscopy, and data were analyzed using ANOVA and paired t tests. Treatments with ICON, S&P, and TEF created a protective material coating of 4.5 ± 1.9 μm, 44.3 ± 8.1 μm, and 84.6 ± 15.7 μm in thickness on the lesion surfaces, respectively. After 15 cycles of erosive and abrasive challenges, enamel or material losses were 21.9 ± 2.3 μm for control, 24.5 ± 4.0 μm for ICON-NE, 24.6 ± 7.4 μm for ICON-AE, 11.2 ± 4.1 μm for S&P, and 3.9 ± 1.9 μm for TEF, respectively. The protective coatings were completely lost in the ICON infiltration groups but remained intact in both the S&P and TEF groups after erosive and abrasive challenges. In contrast to a resin sealant and a flowable composite, ICON infiltration resin was not effective in protecting enamel surfaces from erosive and abrasive wear. Sealant and flowable composite resin may create protective coatings on eroded enamel surfaces and prevent further tissue loss.

  9. Fracture resistance of endodontically treated teeth restored with a bulkfill flowable material and a resin composite.

    Science.gov (United States)

    Isufi, Almira; Plotino, Gianluca; Grande, Nicola Maria; Ioppolo, Pietro; Testarelli, Luca; Bedini, Rossella; Al-Sudani, Dina; Gambarini, Gianluca

    2016-01-01

    To determine and compare the fracture resistance of endodontically treated teeth restored with a bulk fill flowable material (SDR) and a traditional resin composite. Thirty maxillary and 30 mandibular first molars were selected based on similar dimensions. After cleaning, shaping and filling of the root canals and adhesive procedures, specimens were assigned to 3 subgroups for each tooth type (n=10): Group A: control group, including intact teeth; Group B: access cavities were restored with a traditional resin composite (EsthetX; Dentsply-Italy, Rome, Italy); Group C: access cavities were restored with a bulk fill flowable composite (SDR; Dentsply-Italy), except 1.5 mm layer of the occlusal surface that was restored with the same resin composite as Group B. The specimens were subjected to compressive force in a material static-testing machine until fracture occurred, the maximum fracture load of the specimens was measured (N) and the type of fracture was recorded as favorable or unfavorable. Data were statistically analyzed with one-way analysis of variance (ANOVA) and Bonferroni tests (Presin composite and with a bulk fill flowable composite (SDR) was similar in both maxillary and mandibular molars and showed no significant decrease in fracture resistance compared to intact specimens. No significant difference was observed in the mechanical fracture resistance of endodontically treated molars restored with traditional resin composite restorations compared to bulk fill flowable composite restorations.

  10. Antibacterial properties of amalgam and composite resin materials used as cores under crowns.

    Science.gov (United States)

    Al Ghadban, A; Al Shaarani, F

    2012-06-01

    The Aim of this Study was to compare the bacterial growth in the bulk of both amalgam and fluoridated composite resin materials used as cores under crowns at core's surface (in the superficial area of the bulk) and depth levels. With 24 lower premolars, 12 of them were restored with metal posts and amalgam cores (group 1). The rest were restored with glass Fiber-reinforced Composite (FRC) posts and fluoridated composite resin cores (group 2). All specimens were covered with aluminium crowns cemented with resin cement, and then they were soaked in natural saliva for three months. Excoriations abraded from the superficial and the depth areas of the core materials were cultured under aerobic conditions on blood agar plates. After incubation for 2 days, colonies formed on the plates were identified, and the CFU mg(-1) counts were recorded accordingly. Statistical analysis was performed using an independent sample T test. The mean values of CFU mg(-1) counts in group 2 excoriations (surface 39.75, and depth 9.75) were higher than the group 1 excoriations (surface 1.67, and depth 0.42). This study supports the use of amalgam for building up cores due to its antibacterial properties. Composite resin, however, enhanced sizable bacterial growth despite the presence of fluoride.

  11. Rubber-like materials derived from biosourced phenolic resins

    Science.gov (United States)

    Amaral-Labat, G.; Grishechko, L. I.; Silva, G. F. B. Lenz e.; Kuznetsov, B. N.; Fierro, V.; Pizzi, A.; Celzard, A.

    2017-07-01

    The present work describes new gels derived from cheap, abundant and non-toxic wood bark extracts of phenolic nature, behaving like elastomers. Especially, we show that these materials might be used as rubber springs. Such amazing properties were obtained by a quite simple synthesis based on the autocondensation of flavonoid tannins in water at low pH in the presence of a plasticizer. After gelation and drying, the materials presented elastic properties that could be tuned from hard and brittle to quite soft and deformable, depending on the amount of plasticizer in the starting formulation. Not only the materials containing the relevant amount of plasticizer had stress-strain characteristics in quasi-static and cyclic compression similar to most commercial rubber springs, but they presented outstanding fire retardance, surviving 5 min in a flame at 1000°C in air. Neither flame propagation nor drips were noticed during the fire test, and the materials were auto-extinguishable. These excellent features make these materials potential substitutes to usual organic elastomers.

  12. CarbAl Heat Transfer Material

    Science.gov (United States)

    Fink, Richard

    2015-01-01

    The increasing use of power electronics, such as high-current semiconductor devices and modules, within space vehicles is driving the need to develop specialty thermal management materials in both the packaging of these discrete devices and the packaging of modules consisting of these device arrays. Developed by Applied Nanotech, Inc. (ANI), CarbAl heat transfer material is uniquely characterized by its low density, high thermal diffusivity, and high thermal conductivity. Its coefficient of thermal expansion (CTE) is similar to most power electronic materials, making it an effective base plate substrate for state-of-the-art silicon carbide (SiC) super junction transistors. The material currently is being used to optimize hybrid vehicle inverter packaging. Adapting CarbAl-based substrates to space applications was a major focus of the SBIR project work. In Phase I, ANI completed modeling and experimentation to validate its deployment in a space environment. Key parameters related to cryogenic temperature scaling of CTE, thermal conductivity, and mechanical strength. In Phase II, the company concentrated on improving heat sinks and thermally conductive circuit boards for power electronic applications.

  13. Resole resin products derived from fractionated organic and aqueous condensates made by fast-pyrolysis of biomass materials

    Science.gov (United States)

    Chum, H.L.; Black, S.K.; Diebold, J.P.; Kreibich, R.E.

    1993-08-10

    A process for preparing phenol-formaldehyde resole resins by fractionating organic and aqueous condensates made by fast-pyrolysis of biomass materials while using a carrier gas to move feed into a reactor to produce phenolic-containing/neutrals in which portions of the phenol normally contained in said resins are replaced by a phenolic/neutral fractions extract obtained by fractionation.

  14. Radiopacity of different shades of resin-based restorative materials compared to human and bovine teeth.

    Science.gov (United States)

    Pekkan, Gurel; Ozcan, Mutlu

    2012-01-01

    This study evaluated the radiopacity of different shades of resin-based restorative materials and compared the results to human and bovine dental hard tissues. Disk specimens 6 mm in diameter and 1 mm thick (N = 220, n = 10) were prepared from the following restorative materials: · eight shades of nanofilled composite (Aelite Aesthetic Enamel), · seven shades of nanohybrid composite (Grandio Universal), · six shades of photopolymerized polyacid modified compomer (Glasiosite), and · one shade of hybrid composite (X-tra fil U). Human canine dentin (n = 10), bovine enamel (n = 10), and an aluminum (Al) step wedge were used as references. The optical density values of each material were measured from radiographic images using a transmission densitometer. Al step wedge thickness and optical density values were plotted, and equivalent Al thickness (eq Al) values were determined for radiopacity measurements of each material. The data were analyzed using a non-parametric one-way ANOVA (Kruskal-Wallis), and multiple comparisons were made with a Student-Newman-Keuls post hoc test (a = 0.05). Different shades of resin-based restorative materials tested did not reveal statistically significant differences within each material group (p > 0.05). Radiopacity values of the resin-based restorative materials investigated varied depending on their types; however, within different shades of one material type, radiopacity values were comparable. Every shade of nanocomposite material other than Aelite Aesthetic Enamel Incisal LT Gray showed comparable radiopacity to human dentin. Other materials tested demonstrated higher radiopacity compared to human dentin and bovine enamel.

  15. INFLUENCE OF ENVIRONMENTAL CONDITIONS ON PROPERTIES OF IONOMERIC AND RESIN SEALANT MATERIALS

    Science.gov (United States)

    Kantovitz, Kamila Rosamilia; Pascon, Fernanda Miori; Correr, Gisele Maria; Alonso, Roberta Caroline Bruschi; Rodrigues, Lidiany Karla Azevedo; Alves, Marcelo Correa; Puppin-Rontani, Regina Maria

    2009-01-01

    Objectives: The aim of this study was to determine the effect of environmental conditions on the degradation of ionomeric and resin sealant materials. Material and Methods: FluroShield, Vitremer, and Ketac Molar disc-shaped specimens (n=18/material) were prepared, polished, subjected to initial hardness and roughness readings. Six discs of each material were randomly assigned to one of three different storage solutions: 0.3% citric acid (CA), demineralization solution (DE), and remineralization solution (RE). The specimens were individually immersed in 3 mL of the test solutions, which were daily changed. After 15 days of storage, new surface roughness and hardness readings were done. Fluoride release in the solutions was measured within 15 days. Data were analyzed by ANOVA and Tukey's and Contrast tests (α=0.05). Results: The storage in CA increased the roughness of Vitremer and Ketac Molar. A significant reduction in hardness was observed for all materials after storage in all solutions. For all materials, the greatest amounts of fluoride release occurred during the 1st day. FluroShield presented the same patterns of fluoride release in all solutions. Ketac Molar and Vitremer released the highest amounts of fluoride in the CA solution. Conclusions: Ionomeric materials are more susceptible to degradation than resin-based materials under acidic conditions. Acidic conditions lead to a higher fluoride release from ionomeric materials. PMID:19668988

  16. Stickiness of dental resin composite materials to steel, dentin and bonded dentin.

    Science.gov (United States)

    Ertl, Kathrin; Graf, Alexandra; Watts, David; Schedle, Andreas

    2010-01-01

    Stickiness is a vital rheological parameter for the clinical handling behavior of unset resin composite restoratives. The aim of this study was to investigate the stickiness of three different resin composites at 23 degrees C and 37 degrees C tested on steel, dentin and dentin covered with different bonding agents. The stickiness instrument, used in this study consists of a vertical cylindrical stainless steel rod, with a flat circular end, and a platform with a cylindrical mold (diameter: 6.1mm, depth: 2.2mm). The test-material surface temperature and the speed of the rod can be modified. It moves slowly into the prepared mold which is filled with unset composite materials. The degree of stickiness is deducted from the height of the "elevation" the material forms when the plunger is withdrawn from the mold until the steelhead detaches itself from the composite. In this study, stickiness was tested directly to the steel plunger and to dentin slices (uncovered or covered with two different bonding agents) fixed to the plunger rod with a clamp. The coefficients of variation (CVs) were generally less than 0.10, indicating that the stickiness instrument offers an adequately reproducible way of testing stickiness. The tested composite materials varied significantly in stickiness. For all investigated materials a decrease of peak heights with increasing speed was found (for all three materials: psteel and least on bonded dentin. The order of stickiness of composites was not affected by testing the stickiness on the different materials. This method allows the characterization of composite resin materials stickiness to steel, as equivalent to dental steel instruments, and to bonded dentin as equivalent to the tooth cavity after preparation. An ideal material should have a sufficient difference between stickiness on steel and dentin so that it remains in the cavity and is not pulled back by the steel instrument.

  17. Thermal conductivity of 2D nano-structured graphitic materials and their composites with epoxy resins

    OpenAIRE

    Mu, Mulan; Wan, Chaoying; McNally, Tony

    2017-01-01

    Abstract The outstanding thermal conductivity (λ) of graphene and its derivatives offers a potential route to enhance the thermal conductivity of epoxy resins. Key challenges still need to be overcome to ensure effective dispersion and distribution of 2D graphitic fillers throughout the epoxy matrix. 2D filler type, morphology, surface chemistry and dimensions are all important factors in determining filler thermal conductivity and de facto the thermal conductivity of the composite material. ...

  18. Biological Effects of Provisional Resin Materials on Human Dental Pulp Stem Cells.

    Science.gov (United States)

    Jun, S-K; Mahapatra, C; Lee, H-H; Kim, H-W; Lee, J-H

    This study investigated the in vitro cytotoxicity as well as the proinflammatory cytokine expression of provisional resin materials on primary cultured human dental pulp stem cells (hDPSCs). Five commercially available provisional resin materials were chosen (SNAP [SN], Luxatemp [LT], Jet [JE], Revotek LC [RL], and Vipi block [VB]). Eluates that were either polymerizing or already set were added to hDPSCs under serially diluted conditions divided into three different setting times (25% set, 50% set, and 100% set) and incubated for 24 hours with 2× concentrated culture media. Cell cytotoxicity tests were performed by LDH assay and live and dead confocal microscope images. The expression of proinflammatory cytokines in SN and VB was measured using cytokine antibody arrays. Data were analyzed using repeated measures analysis of variance (ANOVA) or ANOVA followed by the Tukey post hoc test at a significance level of pprovisional resin materials during polymerization (SN, LT, and JE) were cytotoxic to hDPSCs and may adversely affect pulp tissue.

  19. Properties of Two Carbon Composite Materials Using LTM25 Epoxy Resin

    Science.gov (United States)

    Cruz, Juan R.; Shah, C. H.; Postyn, A. S.

    1996-01-01

    In this report, the properties of two carbon-epoxy prepreg materials are presented. The epoxy resin used in these two materials can yield lower manufacturing costs due to its low initial cure temperature, and the capability of being cured using vacuum pressure only. The two materials selected for this study are MR50/LTM25, and CFS003/LTM25 with Amoco T300 fiber; both prepregs are manufactured by The Advanced Composites Group. MR50/LTM25 is a unidirectional prepreg tape using Mitsubishi MR50 carbon fiber impregnated with LTM25 epoxy resin. CRS003/LTM25 is a 2 by 2 twill fabric using Amoco T300 fiber and impregnated with LTM25 epoxy resin. Among the properties presented in this report are strength, stiffness, bolt bearing, and damage tolerance. Many of these properties were obtained at three environmental conditions: cold temperature/dry (CTD), room temperature/dry (RTD), and elevated temperature/wet (ETW). A few properties were obtained at room temperature/wet (RTW), and elevated temperature/dry (ETD). The cold and elevated temperatures used for testing were -125 F and 180 F, respectively. In addition, several properties related to processing are presented.

  20. Metallurgical examination of, and resin transfer from, Three Mile Island prefilter liners

    Energy Technology Data Exchange (ETDEWEB)

    McConnell, Jr, J W; Spaletta, H W

    1984-08-01

    Metallurgical examinations were performed on two EPICOR-II prefilter liners at the Idaho National Engineering Laboratory (INEL) to determine conditions of the liners and identify the minimum expected lifetime of those and other liners stored at INEL. The research work was accomplished by EG and G Idaho, Inc. for the EPICOR-II Research and Disposition Program, which is funded by the US Department of Energy. The EPICOR-II prefilter liners were used to filter radionuclides from contaminated water during cleanup of Three Mile Island Unit 2 (TMI-2). The liners were constructed of carbon steel with a phenolic protective coating and contained organic and inorganic ion-exchange filtration media. Program plans call for interim storage of EPICOR-II prefilters at INEL for up to ten years, before final disposal in high integrity containers at the Hanford, Washington commercial disposal site. This report describes the (a) resin transfer process used to empty liners for examination, (b) removal of metallographic sections from those liners, (c) specimen preparation, and (d) findings from metallographic examination of those specimens. A minimum lifetime for the liners is determined and recommendations are given for storage of wastes from future TMI-2 activities.

  1. Capillary Characterization of Fibrous Reinforcement and Optimization of Injection Strategy in Resin Transfer Molding

    Directory of Open Access Journals (Sweden)

    Philippe Causse

    2018-03-01

    Full Text Available During composite manufacturing, minimizing the residual void content is a key issue to ensure optimal mechanical performance of final products. For injection processes such as Resin Transfer Molding (RTM, the impregnation velocity has a direct impact on void creation at the flow front by mechanical entrapment of air bubbles. Previous work proposed to study capillary imbibition in fibrous reinforcement to determine optimal filling conditions during practical manufacturing. The objective of this study is to investigate further this possibility. For that purpose, an improved experimental procedure is proposed to estimate the optimal impregnation velocity from capillary rise tests and understand its effect in parts of varying geometry. Capillary rise experiments were carried out with an enhanced experimental protocol, and a new post processing technique was evaluated to analyze the results. The position of the capillary flow front was then used to deduce the optimal impregnation velocity range based on the Lucas-Washburn flow model. A series of injections were also carried out with a laboratory scale RTM mold to study the influence of flow velocity on the residual void content. Results show that the prediction from capillary characterization is close to the optimal velocity value deduced from manufacturing experiments. The study also highlights the importance of void transport during processing and suggests that the injection strategy (i.e., flow rate history and the mold configuration (i.e., divergent versus convergent flow are important process parameters that may influence void content and cycle time.

  2. Metallurgical examination of, and resin transfer from, Three Mile Island prefilter liners

    International Nuclear Information System (INIS)

    McConnell, J.W. Jr.; Spaletta, H.W.

    1984-08-01

    Metallurgical examinations were performed on two EPICOR-II prefilter liners at the Idaho National Engineering Laboratory (INEL) to determine conditions of the liners and identify the minimum expected lifetime of those and other liners stored at INEL. The research work was accomplished by EG and G Idaho, Inc. for the EPICOR-II Research and Disposition Program, which is funded by the US Department of Energy. The EPICOR-II prefilter liners were used to filter radionuclides from contaminated water during cleanup of Three Mile Island Unit 2 (TMI-2). The liners were constructed of carbon steel with a phenolic protective coating and contained organic and inorganic ion-exchange filtration media. Program plans call for interim storage of EPICOR-II prefilters at INEL for up to ten years, before final disposal in high integrity containers at the Hanford, Washington commercial disposal site. This report describes the (a) resin transfer process used to empty liners for examination, (b) removal of metallographic sections from those liners, (c) specimen preparation, and (d) findings from metallographic examination of those specimens. A minimum lifetime for the liners is determined and recommendations are given for storage of wastes from future TMI-2 activities

  3. Permeability Tests of Fiber Fabrics in the Vacuum Assisted Resin Transfer Molding Process

    Science.gov (United States)

    Changchun, Wang; Guanghui, Bai; Yang, Wang; Boming, Zhang; Lijian, Pan

    2015-08-01

    A special device is designed to measure the in-plane and through-thickness permeability of a preform for the vacuum assisted resin transfer molding (VARTM) process. The device is composed of pressure control module, aluminum experimental platform, thickness test module, and pressure test module, which is controlled by a computer. Two kinds of experiments were conducted for carbon fiber noncrimp biaxial fabrics to verify the reliability of the new device based on constant pressure injection. The two experiments are composed of: (1) testing of in-plane permeability for 1, 5, 10 and 20 layers with the method of the line injection by comparing the two conventional methods; (2) testing of the through-thickness permeability for the laminate denoted as [±45] 20 with the central injection method. The results show: (1) the in-plane permeability decrease with the increase of layer number and the permeability for 20 layers is only 62 % of the one layer; (2) the in-plane permeability is an order of magnitude greater than through-thickness permeability based on experimental results of laminate denoted as [±45] 20. A good agreement obtained between the device and two comparison methods proves the validity of the device.

  4. Influence of Curing Light Attenuation Caused by Aesthetic Indirect Restorative Materials on Resin Cement Polymerization

    Science.gov (United States)

    Pick, Bárbara; Gonzaga, Carla Castiglia; Junior, Washington Steagall; Kawano, Yoshio; Braga, Roberto Ruggiero; Cardoso, Paulo Eduardo Capel

    2010-01-01

    Objectives: To verify the effect of interposing different indirect restorative materials on degree of conversion (DC), hardness, and flexural strength of a dual-cure resin cement. Methods: Discs (2 mm-thick, n=5) of four indirect restorative materials were manufactured: a layered glass-ceramic (GC); a heat-pressed lithium disilicate-based glass-ceramic veneered with the layered glass-ceramic (LD); a micro-hybrid (MH); and a micro-filled (MF) indirect composite resin. The light transmittance of these materials was determined using a double-beam spectrophotometer with an integrating sphere. Bar-shaped specimens of a dual-cure resin cement (Nexus 2/SDS Kerr), with (dual-cure mode) and without the catalyst paste (light-cure mode), were photoactivated through the discs using either a quartz-tungsten-halogen (QTH) or a light-emitting diode (LED) unit. As a control, specimens were photoactivated without the interposed discs. Specimens were stored at 37ºC for 24h before being submitted to FT-Raman spectrometry (n=3), Knoop microhardness (n=6) and three-point bending (n=6) tests. Data were analyzed by ANOVA/Tukey’s test (α=0.05). Results: MH presented the highest transmittance. The DC was lower in light-cure mode than in dual-cure mode. All restorative materials reduced the cement microhardness in light-cure mode. GC and LD with QTH and GC with LED decreased the strength of the cement for both activation modes compared to the controls. Curing units did not affect DC or microhardness, except when the dual-cure cement was photoactivated through LD (LED>QTH). Flexural strength was higher with QTH compared to LED. Conclusions: Differences in transmittance among the restorative materials significantly influenced cement DC and flexural strength, regardless of the activation mode, as well as the microhardness of the resin cement tested in light-cure mode. Microhardness was not impaired by the interposed materials when the resin cement was used in dual-cure mode. PMID:20613921

  5. A comparison of the accuracy of patterns processed from an inlay casting wax, an auto-polymerized resin and a light-cured resin pattern material

    Directory of Open Access Journals (Sweden)

    Praveen Rajagopal

    2012-01-01

    Conclusion: The resin pattern materials studied, undergo a significantly less dimensional change than the inlay waxes on prolonged storage. They would possibly be a better alternative to inlay wax in situations requiring high precision or when delayed investment (more than 1 h of patterns can be expected.

  6. Trends in material choice for posterior restorations in an Israeli dental school: composite resin versus amalgam.

    Science.gov (United States)

    Ben-Gal, Gilad; Weiss, Ervin I

    2011-12-01

    According to a recent American Dental Association survey, posterior composite resin restorations now outnumber amalgam restorations in the United States. Dental schools around the world vary considerably in the extent to which they teach the use of composite resins. We aimed to determine if there has been an increase in the placement of posterior composite restorations in an Israeli dental school and if faculty experience affects the type of posterior restoration placed. In this retrospective study, we recorded and analyzed all the restorations performed by undergraduate students in the last five academic years at the Hebrew University Hadassah School of Dental Medicine in Jerusalem. All clinical records of student treatments between 2004 and 2009 were screened, and direct restorations were registered. Out of 6,094 posterior restorations performed during the study period, 42.3 percent were made of composite resin, increasing from 36.8 percent in 2004-05 to 48.5 percent in 2008-09, an increase of 11.7 percent. When clinical instructors were asked to state their preference if they themselves were to undergo posterior restoration, similar results were obtained. Instructors with less than ten years' experience preferred posterior composite resin restorations in 54.8 percent of the hypothetical situations, compared with 37.2 percent preferred by instructors with ten years of experience or more. It appears that the use of composite resin was influenced mainly by the prevailing trend and was not based on scientific evidence. Dental faculties should define criteria, based on up-to-date clinical studies, for using new materials, taking into consideration differences among instructors regarding treatment concept.

  7. Influence of light-curing units and restorative materials on the micro hardness of resin cements

    Directory of Open Access Journals (Sweden)

    Kuguimiya Rosiane

    2010-01-01

    Full Text Available Aim: The aim of this study was to evaluate the effect of indirect restorative materials (IRMs and light-curing units (LCUs on the micro hardness of dual-cured resin cement. Materials and Methods: A total of 36 cylindrical samples (2 mm thick were prepared with dual-cured resin cement (Relyx ARC photo-activated with either a QTH (Optilight Plus for 40s or a LED (Radii light-curing unit for 65s. Photo-activation was performed through the 2-mm- thick IRMs and the samples were divided into six groups (n=6 according to the combination of veneering materials (without, ceramic and indirect resin and LCUs (QTH and LED. In the control group, the samples were light-cured with a QTH unit without the interposition of any restorative material. Vickers micro hardness test was performed on the top and bottom surfaces of each sample (load of 50 g for 15 secs. The data were statistically analyzed using a three-way ANOVA followed by Tukey x s post-hoc test ( P < 0.05. Results: There were no statistically significant differences on the top surface between the light curing-units ( P > 0.05; however, the LED provided greater hardness on the bottom surface when a ceramic material was used ( P < 0.05. The mean hardness in photo-activated samples, in which there was no interposition of indirect materials, was significantly greater ( P < 0.01. Conclusions: It may be concluded that the interposition of the restorative material decreased the micro hardness in the deeper cement layer. Such decrease, however, was lower when the ceramic was interposed and the cement light-cured with LED.

  8. Tension-Compression Fatigue Behavior of a Carbon Fiber/Epoxy (IM7/EPON 862) Composite Fabricated Using Vacuum Assisted Resin Transfer Molding Process

    National Research Council Canada - National Science Library

    Katwyk, David W

    2007-01-01

    .... One of these new processing methods is the vacuum assisted resin transfer molding (VARTM) process, which shows promise in producing large structural components that have good properties at a lower cost than traditional manufacturing methods...

  9. Fabrication and Evaluation of Graphite Fiber-Reinforced Polyimide Composite Tube Forms Using Modified Resin Transfer Molding

    Science.gov (United States)

    Exum, Daniel B.; Ilias, S.; Avva, V. S.; Sadler, Bob

    1997-01-01

    The techniques necessary for the fabrication of a complex three-dimensional tubular form using a PMR-type resin have been developed to allow for the construction of several tubes with good physical and mechanical properties. Employing established resin transfer molding practices, the relatively non-hazardous AMB-21 in acetone formulation was used to successfully impregnate four layers of AS4 braided graphite fiber preform previously loaded around an aluminum cylindrical core in an enclosed mold cavity. Using heat and vacuum, the solvent was evaporated to form a prepreg followed by a partial imidization and removal of condensation products. The aluminum core was replaced by a silicone rubber bladder and the cure cycle continued to the final stage of 550 F with a bladder internal pressure of 200 lbs/sq in while simultaneously applying a strong vacuum to the prepreg for removal of any additional imidization products. A combination of several modifications to the standard resin transfer molding methodology enabled the mold to 'breathe', allowing the imidization products a pathway for escape. AMB-21 resin was chosen because of the carcinogenic nature of the primary commercial polyimide PMR-15. The AMB-21 resin was formulated using commercially available monomers or monomer precursors and dissolved in a mixture of methyl alcohol and acetone. The viscosity of the resulting monomer solution was checked by use of a Brookfield rheometer and adjusted by adding acetone to an easily pumpable viscosity of about 600 cP. In addition, several types of chromatographic and thermal analyses were of the braids, and excess handling of the preforms broke some of the microscopic fibers, needlessly decreasing the strength of the finished part. In addition, three dimensional braided preforms with fibers along the length of the tube will be significantly stronger in tension than the braided preforms used in this study.

  10. New Anion-Exchange Resins for Improved Separations of Nuclear Materials

    International Nuclear Information System (INIS)

    Bartsch, Richard A.; Barr, Mary E.

    2001-01-01

    Improved separations of nuclear materials will have a significant impact upon a broad range of DOE activities. DOE-EM Focus Areas and Crosscutting Programs have identified improved methods for the extraction and recovery of radioactive metal ions from process, waste, and environmental waters as critical needs for the coming years. We propose to develop multifunctional anion-exchange resins that facilitate anion uptake by carefully controlling the structure of the anion receptor site. Our new ion-exchange resins interface the field of ion-specific chelating ligands with robust, commercial ion-exchange technology to provide materials which exhibit superior selectivity and kinetics of sorption and desorption. The following Focus Areas and Crosscutting Programs have described needs that would be favorably impacted by the new material: Efficient Separations and Processing - radionuclide removal from aqueous phases; Plutonium - Pu, Am or total alpha removal to meet regulatory requirement s before discharge to the environment; Plumes - U and Tc in groundwater, U, Pu, Am, and Tc in soils; Mixed Waste - radionuclide partitioning; High-Level Tank Waste - actinide and Tc removal from supernatants and/or sludges. The basic scientific issues which need to be addressed are actinide complex speciation along with modeling of metal complex/functional site interactions in order to determine optimal binding-site characteristics. Synthesis of multifunctionalized extractants and ion-exchange materials that implement key features of the optimized binding site, and testing of these materials, will provide feedback to the modeling and design activities. Resin materials which actively facilitate the uptake of actinide complexes from solution should display both improved selectivity and kinetic properties. The long-range implications of this research, however, go far beyond the nuclear complex. This new methodology of ''facilitated uptake'' could revolutionize ion-exchange technology

  11. Development of microwave absorbing materials prepared from a polymer binder including Japanese lacquer and epoxy resin

    Science.gov (United States)

    Iwamaru, T.; Katsumata, H.; Uekusa, S.; Ooyagi, H.; Ishimura, T.; Miyakoshi, T.

    Microwave absorption composites were synthesized from a poly urushiol epoxy resin (PUE) mixed with one of microwave absorbing materials; Ni-Zn ferrite, Soot, Black lead, and carbon nano tube (CNT) to investigate their microwave absorption properties. PUE binders were specially made from Japanese lacquer and epoxy resin, where Japanese lacquer has been traditionally used for bond and paint because it has excellent beauty. Japanese lacquer solidifies with oxygen contained in air's moisture, which has difficulty in making composite, but we improved Japanese lacquer's solidification properties by use of epoxy resin. We made 10 mm thickness composite samples and cut them into toroidal shape to measure permittivity, permeability, and reflection loss in frequencies ranging from 50 Hz to 20 GHz. Electric magnetic absorber's composites synthesized from a PUE binders mixed either with Soot or CNT showed significantly higher wave absorption over -27 dB than the others at frequencies around 18 GHz, although Japanese lacquer itself doesn't affect absorption. This means Japanese lacquer can be used as binder materials for microwave absorbers.

  12. [Color stability of ceromer of different thicknesses and resin adhesive materials of different types after accelerated aging].

    Science.gov (United States)

    Likai, Wang; Yanan, Liu; Yan, Zheng; Pingping, Li

    2015-04-01

    This study aims to investigate the color stability of ceromer with different thicknesses and different types of resin adhesive materials after accelerated aging and provide references for clinical application and selections. Nine groups of experimental samples were used, and each group contained five samples. We made joint samples with ceromer having three different thicknesses (1.00, 0.75, 0.50 mm) combined with three different resin adhesive materials (RelyX Veneer, RelyX Unicem, Filtek Z350 Flow), respectively. All samples were placed into Xenon Lamp Aging Instrument to implement accelerated aging. Spectrophotometer was used to measure the lightness (L*), red green color value (a*), and blue yellow color value (b*) of all samples before and after accelerated aging. The change of lightness (ΔL), red green color value (Δa), blue yellow color value (Δb), and color variation (ΔE) were also calculated. We investigated the influence of ceromer veneer thicknesses and resin adhesive material types on color variation by two-factor analysis of variance. The thickness and type factors showed significant influence on ΔE values, and exhibited interactions (P Ceromer veneer thickness and resin adhesive material types could affect the color stability of ceromer veneer and resin adhesive materials. The changes in lightness and color in ceromer veneer and resin adhesive materials are considered clinically acceptable after accelerated aging.

  13. Effects of LDEF flight exposure on selected polymer matrix resin composite materials

    Science.gov (United States)

    Slemp, Wayne S.; Young, Philip R.; Witte, William G., Jr.; Shen, James Y.

    1992-01-01

    The characterization of selected graphite fiber reinforced epoxy (934 and 5208) and polysulfone (P1700) matrix resin composites materials which received over five years and nine months of exposure to the low earth orbit (LEO) environment in experiment AO134 on the Long Duration Exposure Facility is reported. The changes in mechanical properties of ultimate tensile strength and tensile modulus for exposed flight specimens are compared to the three sets of control specimens. Marked changes in surface appearance are discussed, and resin loss is reported. The chemical characterization including infrared, thermal, and selected solution property measurements showed that the molecular structure of the polymetric matrix had not changed significantly in response to this exposure.

  14. Compilation of radiation damage test data. Pt. 2. Thermoset and thermoplastic resins, composite materials

    International Nuclear Information System (INIS)

    Tavlet, M.; Fontaine, A.; Schoenbacher, H.

    1998-01-01

    This catalogue summarizes radiation damage test data on thermoplastic and thermoset resins and composites. Most of them are epoxy resins used as insulator for magnet coils. Many results are also given for new engineering thermoplastics which can be used either for their electrical properties or for their mechanical properties. The materials have been irradiated either in a 60 Co source, up to integrated absorbed doses between 200 kGy and a few megagrays, at dose rates of the order of 1 Gy/s, or in a nuclear reactor at dose rates of the order of 50 Gy/s, up to doses of 100 MGy. The flexural strength, the deformation and the modulus of elasticity have been measured on irradiated and non-irradiated samples, according to the recommendations of the International Electrotechnical Commissions. The results are presented in the form of tables and graphs to show the effect of the absorbed dose on the measured properties. (orig.)

  15. Natural convection heat transfer from a heated horizontal cylinder with Microencapsulated Phase-Change-Material slurries

    International Nuclear Information System (INIS)

    Kubo, Shinji; Akino, Norio; Tanaka, Amane; Nagashima, Akira

    1998-01-01

    The present study investigates natural convection heat transfer from a heated cylinder cooled by a water slurry of Microencapsulated Phase Change Material (MCPCM). A normal paraffin hydrocarbon with carbon number of 18 and melting point of 27.9degC, is microencapsulated by Melamine resin into particles of which average diameter is 9.5 μm and specific weight is same as water. The slurry of the MCPCM and water is put into a rectangular enclosure with a heated horizontal cylinder. The heat transfer coefficients of the cylinder were evaluated. Changing the concentrations of PCM and temperature difference between cylinder surface and working fluid. Addition of MCPCM into water, the heat transfer is enhanced significantly comparison with pure water in cases with phase change and is reduced slightly in cases without phase change. (author)

  16. Optical absorption of epoxy resin and its role in the laser ultrasonic generation mechanism in composite materials

    International Nuclear Information System (INIS)

    Stratoudaki, T.; Edwards, C.; Dixon, S.; Palmer, S.B.

    2003-01-01

    Epoxy resins are used in various applications and are essential to the fabrication of carbon fibre reinforced composite materials (CFRCs). This paper investigates laser generated ultrasound in epoxy resins using three different lasers, a TEA CO2, a Nd:YAG and a XeCl excimer. In these partially transparent materials the ultrasonic generation mechanism is directly related to the optical absorption depth which can therefore be measured directly from the ultrasonic waveforms using for example a Michelson interferometer as detector. The present work aims firstly to relate the observed amplitude of the longitudinal wave to the optical absorption depth of the epoxy and secondly to evaluate the role of the epoxy resin to the generation of the ultrasound in CFRCs. For the latter, comparative results of generation efficiency between the three wavelengths are presented and an attempt is made to understand the way that the resin matrix influences the generation mechanism of ultrasound in composite materials

  17. Color stability of denture acrylic resins and a soft lining material against tea, coffee, and nicotine.

    Science.gov (United States)

    Imirzalioglu, Pervin; Karacaer, Ozgul; Yilmaz, Burak; Ozmen Msc, Ilknur

    2010-02-01

    The purpose of this study was to investigate the effect of four solutions [saliva (control group), saliva+tea, saliva+coffee, saliva+nicotine] on the color of different denture base acrylic resins (heat-polymerized, injection-molded, autopolymerized) and a soft denture liner. Twenty specimens from each type of test material were prepared (2.5 mm diameter, 2 mm thickness). Five specimens from each test material (heat-polymerized, chemically polymerized, injection-molded acrylic resin, soft denture reliner) were stored in each solution in 37 degrees C in a dark environment. Colorimetric measurements were done on the 1st, 7th, and 30th days. Color differences among specimens immersed in saliva (control group), and staining solutions were evaluated over time. Data were statistically analyzed with one-way analysis of variance (ANOVA) (alpha= 0.05). ANOVA was followed by Tukey test to find which groups differed from each other. Significant color shifts occurred in heat-polymerized and injection-molded acrylic resins in coffee and in soft liner in nicotine over time (p 1). The color shift of soft liner in nicotine was significantly different than that of the remainder of the test materials in nicotine (p 0.05). The effect of staining solutions on the color of each test material in each session was perceivable by the human eye (DeltaE > 1); however, the color shifts of all test materials were clinically acceptable (DeltaE < 3.7) except for soft liner in nicotine, which was not clinically acceptable over time. Therefore, minimizing drinking of such beverages and use of tobacco, particularly when soft liner is applied, may be advantageous for denture wearers for long-term color stability.

  18. [Research on bond durability among different core materials and zirconia ceramic cemented by self-adhesive resin cements].

    Science.gov (United States)

    Xinyu, Luo; Xiangfeng, Meng

    2017-02-01

    This research estimated shear bond durability of zirconia and different substrates cemented by two self-adhesive resin cements (Clearfil SA Luting and RelyX U100) before and after aging conditioning. Machined zirconia ceramic discs were cemented with four kinds of core material (cobalt-chromium alloy, flowable composite resin core material, packable composite resin, and dentin) with two self-adhesive resin cements (Clearfil SA Luting and RelyX U100). All specimens were divided into eight test groups, and each test group was divided into two subgroups. Each subgroup was subjected to shear test before and after 10 000 thermal cycles. All factors (core materials, cements, and thermal cycle) significantly influenced bond durability of zirconia ceramic (P0.05); observed shear bond strength was significantly higher than those of other substrates (Presin core material, and packable composite resin than that of RelyX U100 (P0.05). Different core materials and self-adhesive resin cements can significantly affect bond durability of zirconia ceramic. 
.

  19. Optimization of Resin Infusion Processing for Composite Pipe Key-Part and K/T Type Joints Using Vacuum-Assisted Resin Transfer Molding

    Science.gov (United States)

    Wang, Changchun; Bai, Guanghui; Yue, Guangquan; Wang, Zhuxi; Li, Jin; Zhang, Boming

    2016-10-01

    In present study, the optimization injection processes for manufacturing the composite pipe key-part and K/T type joints in vacuum-assisted resin transfer molding (VARTM) were determined by estimating the filling time and flow front shape of four kinds of injection methods. Validity of the determined process was proved with the results of a scaling-down composite pipe key-part containing of the carbon fiber four axial fabrics and a steel core with a complex surface. In addition, an expanded-size composite pipe part was also produced to further estimate the effective of the determined injection process. Moreover, the resin injection method for producing the K/T type joints via VARTM was also optimized with the simulation method, and then manufactured on a special integrated mould by the determined injection process. The flow front pattern and filling time of the experiments show good agreement with that from simulation. Cross-section images of the cured composite pipe and K/T type joints parts prove the validity of the optimized injection process, which verify the efficiency of simulation method in obtaining a suitable injection process of VARTM.

  20. Edge chipping resistance and flexural strength of polymer infiltrated ceramic network and resin nanoceramic restorative materials.

    Science.gov (United States)

    Argyrou, Renos; Thompson, Geoffrey A; Cho, Seok-Hwan; Berzins, David W

    2016-09-01

    Two novel restorative materials, a polymer infiltrated ceramic network (PICN) and a resin nanoceramic (RNC), for computer-assisted design and computer-assisted manufacturing (CAD-CAM) applications have recently become commercially available. Little independent evidence regarding their mechanical properties exists to facilitate material selection. The purpose of this in vitro study was to measure the edge chipping resistance and flexural strength of the PICN and RNC materials and compare them with 2 commonly used feldspathic ceramic (FC) and leucite reinforced glass-ceramic (LRGC) CAD-CAM materials that share the same clinical indications. PICN, RNC, FC, and LRGC material specimens were obtained by sectioning commercially available CAD-CAM blocks. Edge chipping test specimens (n=20/material) were adhesively attached to a resin substrate before testing. Edge chips were produced using a 120-degree, sharp, conical diamond indenter mounted on a universal testing machine and positioned 0.1 to 0.7 mm horizontally from the specimen's edge. The chipping force was plotted against distance to the edge, and the data were fitted to linear and quadratic equations. One-way ANOVA determined intergroup differences (α=.05) in edge chipping toughness. Beam specimens (n=22/material) were tested for determining flexural strength using a 3-point bend test. Weibull statistics determined intergroup differences (α=.05). Flexural modulus and work of fracture were also calculated, and 1-way ANOVA determined intergroup differences (α=.05) RESULTS: Significant (Pmaterials for the 4 mechanical properties. Specifically, the material rankings were edge chipping toughness: RNC>LRGC=FC>PICN; flexural strength: RNC=LRGC>PICN>FC; flexural modulus: RNCLRGC=PICN>FC. The RNC material demonstrated superior performance for the mechanical properties tested compared with the other 3 materials. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All

  1. How much do resin-based dental materials release? A meta-analytical approach.

    Science.gov (United States)

    Van Landuyt, K L; Nawrot, Tim; Geebelen, B; De Munck, J; Snauwaert, J; Yoshihara, K; Scheers, Hans; Godderis, Lode; Hoet, P; Van Meerbeek, B

    2011-08-01

    Resin-based dental materials are not inert in the oral environment, and may release components, initially due to incomplete polymerization, and later due to degradation. Since there are concerns regarding potential toxicity, more precise knowledge of the actual quantity of released eluates is necessary. However, due to a great variety in analytical methodology employed in different studies and in the presentation of the results, it is still unclear to which quantities of components a patient may be exposed. The objective of this meta-analytical study was to review the literature on the short- and long-term release of components from resin-based dental materials, and to determine how much (order of magnitude) of those components may leach out in the oral cavity. Out of an initial set of 71 studies, 22 were included. In spite of the large statistical incertitude due to the great variety in methodology and lack of complete information (detection limits were seldom mentioned), a meta-analytical mean for the evaluated eluates was calculated. To relate the amount of potentially released material components with the size of restorations, the mean size of standard composite restorations was estimated using a 3D graphical program. While the release of monomers was analyzed in many studies, that of additives, such as initiators, inhibitors and stabilizers, was seldom investigated. Significantly more components were found to be released in organic than in water-based media. Resin-based dental materials might account for the total burden of orally ingested bisphenol A, but they may release even higher amounts of monomers, such as HEMA, TEGDMA, BisGMA and UDMA. Compared to these monomers, similar or even higher amounts of additives may elute, even though composites generally only contain very small amounts of additives. A positive correlation was found between the total quantity of released eluates and the volume of extraction solution. There is a clear need for more accurate

  2. New anion-exchange resins for improved separations of nuclear materials

    International Nuclear Information System (INIS)

    Barr, M.E.; Bartsch, R.A.

    1998-01-01

    'The overall objective of this research is to develop a predictive capability which allows the facile design and implementation of multi-functionalized anion-exchange materials which selectively sorb metal complexes of interest from targeted process, waste, and environmental streams. The basic scientific issues addressed are actinide complex speciation along with modeling of the metal complex/functional-site interactions in order to determine optimal binding-site characteristics. The new ion-exchange resins interface the rapidly developing field of ion-specific chelating ligands with robust, commercial ion-exchange technology. Various Focus Areas and Crosscutting Programs have described needs that would be favorably impacted by the new materials: Efficient Separations and Processing; Plutonium; Plumes; Mixed Waste; High-Level Tank Waste. Sites within the DOE complex which would benefit from the improved anion-exchange technology include Hanford, INEL, Los Alamos, Oak Ridge, and Savannah River. As of April 1998, this report summarizes work after 1.6 years of a 3-year project. The authors technical approach combines empirical testing with theoretical modeling (applied in an iterative mode) in order to determine optimal binding-site characteristics. They determine actinide-complex speciation in specific media, then develop models for the metal complex/functional-site interactions Synthesis and evaluation of multi-functionalized extractants and ion-exchange materials that implement key features of the optimized binding site provide feedback to the modeling and design activities. Resin materials which actively facilitate the uptake of actinide complexes from solution should display both improved selectivity and kinetic properties. The implementation of the bifunctionality concept involves N-derivatization of pyridinium units from a base poly(4-vinylpyridine) resin with a second cationic site such that the two anion-exchange sites are linked by spacer arms of varying

  3. Thermal conductivity of 2D nano-structured graphitic materials and their composites with epoxy resins

    Science.gov (United States)

    Mu, Mulan; Wan, Chaoying; McNally, Tony

    2017-12-01

    The outstanding thermal conductivity (λ) of graphene and its derivatives offers a potential route to enhance the thermal conductivity of epoxy resins. Key challenges still need to be overcome to ensure effective dispersion and distribution of 2D graphitic fillers throughout the epoxy matrix. 2D filler type, morphology, surface chemistry and dimensions are all important factors in determining filler thermal conductivity and de facto the thermal conductivity of the composite material. To achieve significant enhancement in the thermal conductivity of epoxy composites, different strategies are required to minimise phonon scattering at the interface between the nano-filler and epoxy matrix, including chemical functionalisation of the filler surfaces such that interactions between filler and matrix are promoted and interfacial thermal resistance (ITR) reduced. The combination of graphitic fillers with dimensions on different length scales can potentially form an interconnected multi-dimensional filler network and, thus contribute to enhanced thermal conduction. In this review, we describe the relevant properties of different 2D nano-structured graphitic materials and the factors which determine the translation of the intrinsic thermal conductivity of these 2D materials to epoxy resins. The key challenges and perspectives with regard achieving epoxy composites with significantly enhanced thermal conductivity on addition of 2D graphitic materials are presented.

  4. Bonding of resin to dentin. Interactions between materials, substrate and operators.

    Science.gov (United States)

    Jacobsen, Thomas

    2003-01-01

    The general aim of this thesis was to identify and study factors that affect bonding between resin and dentin, including operator variability. Bonding sites were generated in vivo and in vitro and compared using SEM. The effects of experimental water- or acetone-based primers on shear bond strength to dentin were studied in vitro. Fourier transform infrared spectroscopy was used to establish any detrimental effects from water on polymerization by determining the degree of conversion of thin films of resin. The interaction between phosphoric acid and dentin was analyzed by measuring calcium leaching by use of atomic absorption spectroscopy. Bond strength of composite resin was measured to dentin with various degrees of demineralization. Gap formation adjacent to composite restorations in standardized dentin cavities was studied in vitro by confocal microscopy. A similar morphological appearance was found for bonding sites generated in vitro vs. in vivo. An acetone-based primer was more dependent on a moist bonding technique than was a water-based system. However, water might influence bonding by interfering with the polymerization of the resin. Calcium leaching from dentin can be predicted by use of a solubility phase diagram. No correlation could be established between calcium leaching and bond strength. Gap formation was more dependent on the operator than the choice of material. A simplified all-in-one adhesive showed less operator variability compared to more complex bonding systems. In vitro bond testing may well indicate the outcome of in vivo trials. The solvents used in bonding agents will influence the performance and, presumably, technique sensitivity. Water rinse time after etching might be a more important consideration than etch time. In spite of the relative importance of the results presented above, the outcome of the multi-operator trial could not be predicted.

  5. Technologies of bearings systems production from composite materials by polyester resin injection into the closed mold

    Directory of Open Access Journals (Sweden)

    Аnatoliy M. Turenko

    2014-12-01

    Full Text Available An analysis of modern technologies for manufacturing components and bearing systems made of composite materials has been conducted. These technologies are based on the polyester resin injection method and do not require high financial costs in manufacturing. The proposed method, due to the low cost of tooling, is convenient to produce a wide range of items made of composite materials, both in large-scale and single-piece production. Composite materials are intensively used in automotive industry, especially for motor racing vehicles’ parts. These technologies allow to solve the problem of creating ultra-light assemblies for modern car bodies, energy-absorbing passive safety elements and other high-loaded parts. They provide better strength and weight characteristics and better specific energy-output ratio of passive safety elements, as compared to conventional materials (metals and plastics. Considering the above, the most appropriate technology for the automotive industry has been assessed with that choice substantiation.

  6. Optimal Composite Material for Low Cost Fabrication of Large Composite Aerospace Structures using NASA Resins or POSS Nanoparticle Modifications

    Science.gov (United States)

    Lamontia, Mark A.; Gruber, Mark B.; Jensen, Brian J.

    2006-01-01

    Thermoplastic laminates in situ consolidated via tape or tow placement require full mechanical properties. Realizing full properties requires resin crystallinity to be controlled - partial crystallinity leads to unacceptably low laminate compression properties. There are two approaches: utilize an amorphous matrix resin; or place material made from a semi-crystalline resin featuring kinetics faster than the process. In this paper, a matrix resin evaluation and trade study was completed with commercial and NASA amorphous polyimides on the one hand, and with PEKK mixed with POSS nanoparticles for accelerated crystallinity growth on the other. A new thermoplastic impregnated material, 6 mm wide (0.25-in) AS-4 carbon/LaRC(TradeMark)8515 dry polyimide tow, was fabricated. Since LaRC(TradeMark)8515 is fully amorphous, it attains full properties following in situ consolidation, with no post processing required to build crystallinity. The tow in situ processing was demonstrated via in situ thermoplastic filament winding it into rings.

  7. Testing Penetration of Epoxy Resin and Diamine Hardeners through Protective Glove and Clothing Materials.

    Science.gov (United States)

    Henriks-Eckerman, Maj-Len; Mäkelä, Erja A; Suuronen, Katri

    2015-10-01

    Efficient, comfortable, yet affordable personal protective equipment (PPE) is needed to decrease the high incidence of allergic contact dermatitis arising from epoxy resin systems (ERSs) in industrial countries. The aim of this study was to find affordable, user-friendly glove and clothing materials that provide adequate skin protection against splashes and during the short contact with ERS that often occurs before full cure. We studied the penetration of epoxy resin and diamine hardeners through 12 glove or clothing materials using a newly developed test method. The tests were carried out with two ERS test mixtures that had a high content of epoxy resin and frequently used diamine hardeners of different molar masses. A drop (50 µl) of test mixture was placed on the outer surface of the glove/clothing material, which had a piece of Fixomull tape or Harmony protection sheet attached to the inner surface as the collection medium. The test times were 10 and 30 min. The collecting material was removed after the test was finished and immersed into acetone. The amounts of diglycidyl ether of bisphenol A (DGEBA), isophorone diamine (IPDA), and m-xylylenediamine (XDA) in the acetone solution were determined by gas chromatography with mass spectrometric detection. The limit for acceptable penetration of XDA, IPDA, and DGEBA through glove materials was set at 2 µg cm(-2). Penetration through the glove materials was 1.4 µg cm(-2) or less. The three tested chemical protective gloves showed no detectable penetration (clothing materials were found to provide adequate protection during short contact with ERS, in the form of, for example, disposable gloves or clothing materials suitable for aprons and as additional protective layers on the most exposed parts of clothing, such as the front of the legs and thighs and under the forearms. Every ERS combination in use should be tested separately to find the best skin protection material, and this can be done by using this simple

  8. Are linear elastic material properties relevant predictors of the cyclic fatigue resistance of dental resin composites?

    Science.gov (United States)

    Belli, Renan; Petschelt, Anselm; Lohbauer, Ulrich

    2014-04-01

    The aim of this study was to measure the linear elastic material properties of direct dental resin composites and correlate them with their fatigue strength under cyclic loading. Bar specimens of twelve resin composites were produced according to ISO 4049 and tested for elastic modulus (Emod) in 3-point bending (n=10), flexural strength (FS) (n=15) and single-edge-notch-beam fracture toughness (FT) (n=15), both in 4-point bending. Using the same specimen geometry, the flexural fatigue strength (FFS) was determined using the staircase approach after 10(4) cycles at 0.5 Hz in 4-point bending (n=25). The observation of the fracture surface and fracture profiles was conducted using a scanning electron microscope in order to evaluate the respective fracture mechanisms according to the two different loading conditions. Materials were ranked differently according to the tested parameters. Only weak correlations were found between any of the initial properties and FFS or strength loss. The best correlation to FFS was found to be the Emod (r(2)=0.679), although only slightly. Crack path in both loading conditions was mainly interparticle, with the crack propagating mainly within the matrix phase for fatigued specimens and eventually through the filler/matrix interface for statically loaded specimens. Fracture of large particles or prepolymerized fillers was only observed in specimens of FS and FT. Initial properties were better associated with microstructural features, whereas the fatigue resistance showed to be more dependent on aspects relating to the matrix phase. Our results show that linear elastic properties such as elastic modulus, flexural strength and fracture toughness are not good descriptors of the fatigue resistance of dental resin composite under cyclic bending, and may therefore have limited clinical relevance. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  9. Removal of radioactive materials and heavy metals from water using magnetic resin

    Science.gov (United States)

    Kochen, Robert L.; Navratil, James D.

    1997-01-21

    Magnetic polymer resins capable of efficient removal of actinides and heavy metals from contaminated water are disclosed together with methods for making, using, and regenerating them. The resins comprise polyamine-epichlorohydrin resin beads with ferrites attached to the surfaces of the beads. Markedly improved water decontamination is demonstrated using these magnetic polymer resins of the invention in the presence of a magnetic field, as compared with water decontamination methods employing ordinary ion exchange resins or ferrites taken separately.

  10. Mechanical and Physical Properties of Two Different Resin-based Materials: A Comparative Study.

    Science.gov (United States)

    Baeshen, Hosam; Alturki, Basem N; Albishi, Wjoud W; Alsadi, Fahad M; El-Tubaigy, Khaled M

    2017-10-01

    The purpose of this study was to evaluate the degree of conversion (DC) of two different resin-based composite materials (nanofill composite and ormocer) and correlate it with some mechanical properties of these two restorative materials. Two different resin-based materials (Filtek Supreme XT and Admira) were tested. A total of 30 samples of each type of selected composite were prepared. Specimens were immersed in distilled water for 24 hours. Then, the specimens were subjected to DC, hardness, and diametral tensile strength (DTS) measurements. The data obtained were tabulated for statistical analysis. The t-test was used to detect the significant difference among the variables tested in this study. Furthermore, the interrelationship between the studied parameters was investigated using a simple correlation coefficient statistical test. Statistically significant differences were observed regarding DC, hardness, and DTS. Filtek Supreme XT presented the highest values. There was a positive correlation between DC and hardness. Also there was a correlation between DC and DTS, but it was not significant. Under the tested experimental conditions, the DC of Filtek Supreme XT was higher than that of ormocer. Accordingly, Filtek Supreme XT showed better mechanical properties. Filtek Supreme XT showed superior mechanical properties. Therefore, orthodontic bracket-based composite combinations may also be expected to perform well clinically over the lifetime of a bonded orthodontic appliance.

  11. A Study of Resin as Master Jewellery Material, Surface Quality and Machining Time Improvement by Implementing Appropriate Cutting Strategy

    Directory of Open Access Journals (Sweden)

    Puspaputra Paryana

    2017-01-01

    Full Text Available This paper deals with a research about art and jewellery product machining that focused in the selection of appropriate material for jewellery master which is machined by CNC. CNC is used for better surface finish for no undercut design and more complex ornament. The need of production speed requires minimum process without reducing the quality of detail ornament significantly. Problems occur when high surface quality is required. In that condition high speed spindle is used with low feeding speed, as a result is high temperature in cutter-material area will melt the resin and build the build-up edge (BUE. Due to the existence of BUE, the cutting tool will no longer cut the resin, as a result the resin will then melt due to friction and the melt resin will then stuck on the relief and surface finish become worst and rework should be done. When required surface is achieved problem also occur in next going process, that is silicon mould making. Due to galvanization process for silicon at about 170°C, resin material may be broken or cracked. Research is then conducted to select appropriate resin type suitable for all production steps.

  12. Pressure transmission area and maximum pressure transmission of different thermoplastic resin denture base materials under impact load.

    Science.gov (United States)

    Nasution, Hubban; Kamonkhantikul, Krid; Arksornnukit, Mansuang; Takahashi, Hidekazu

    2018-01-01

    The purposes of the present study were to examine the pressure transmission area and maximum pressure transmission of thermoplastic resin denture base materials under an impact load, and to evaluate the modulus of elasticity and nanohardness of thermoplastic resin denture base. Three injection-molded thermoplastic resin denture base materials [polycarbonate (Basis PC), ethylene propylene (Duraflex), and polyamide (Valplast)] and one conventional heat-polymerized acrylic resin (PMMA, SR Triplex Hot) denture base, all with a mandibular first molar acrylic resin denture tooth set in were evaluated (n=6). Pressure transmission area and maximum pressure transmission of the specimens under an impact load were observed by using pressure-sensitive sheets. The modulus of elasticity and nanohardness of each denture base (n=10) were measured on 15×15×15×3mm 3 specimen by using an ultramicroindentation system. The pressure transmission area, modulus of elasticity, and nanohardness data were statistically analyzed with 1-way ANOVA, followed by Tamhane or Tukey HSD post hoc test (α=.05). The maximum pressure transmission data were statistically analyzed with Kruskal-Wallis H test, followed by Mann-Whitney U test (α=.05). Polymethyl methacrylate showed significantly larger pressure transmission area and higher maximum pressure transmission than the other groups (Pdenture bases (Pthermoplastic resin denture base materials. Differences in the modulus of elasticity and nanohardness of each type of denture base were demonstrated. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  13. Studi Eksperimental Laju Keausan Material Gigi Tiruan dari Resin Akrilik Berpenguat Fiberglass dengan Variasi Susunan Serat Penguat

    Directory of Open Access Journals (Sweden)

    Prastika Kristasari

    2017-01-01

    Full Text Available Resin akrilik adalah salah satu material yang mulai banyak digunakan sebagai salah satu material untuk pembuatan gigi tiruan. Penelitian sebelumnya tentang analisis pengujian laju keausan resin akrilik berpenguat serat pada dental prosthesis pada kondisi dry sliding menunjukkan hasil nilai laju keausan berkurang dengan adanya penambahan serat[1]. Saat ini belum ada kajian mengenai laju keausan resin akrilik berpenguat serat pada kondisi wet sliding dengan variasi pola susunan serat yang berbeda dengan kondisi terendam cairan saliva buatan. Metode pengujian ekperimental ini menggunakan alat uji keausan tribometer tipe pin on disk.  Material untuk pin dan disk menggunakan material dari resin akrilik berpenguat serat. Disk diputar dan bergesekan dengan pin. Variabel tetap pengujian ini yaitu panjang lintasan sejauh 505,92 m, beban sebesar 2 kg, dan sliding speed sebesar 0,07 m/s. Perlakuan gesekan dilakukan pada resin akrilik berpenguat serat dengan variasi susunan serat 0%, 7% berpola 6 mm serat acak, dan 7% berpola 6 mm serat teratur. Spesimen direndam dahulu dan saat pengujian keausan dikondisikan terendam dalam cairan saliva buatan. Kemudian, spesimen tersebut dianalisis laju keausannya dan diamati gambar mikro dari permukaan spesimen. Hasil dari penelitian adalah data pengujian berupa nilai laju keausan spesifik terbesar sebesar 0.0126 mm3/Nm yang terdapat pada material resin akrilik tanpa penguat serat dan nilai laju keausan yang terkecil yaitu pada material resin akrilik berpenguat 7% serat berpola teratur sebesar 0.0006 mm3/Nm. Hasil foto mikro menunjukkan bahwa mekanisme keausan yang paling dominan terjadi adalah keausan abrasif dan keausan fatigue.

  14. Rheological analysis of the phenolic and furfuryl resins used in the carbon materials processing

    Directory of Open Access Journals (Sweden)

    Edson Cocchieri Botelho

    2000-04-01

    Full Text Available Carbon materials processing is an advanced technology due to its aerospace and medical applications. In the aerospace area one can mention the carbon/carbon composites used in rockets and aeronautical brakes; in the medical area one can mention the intrabody implant tools such as heart and hydrocephalic valves and pacemaker electrode tips. The highly sophisticated purpose of its application requires a very tight processing control, which defines the microstructure the mechanical, thermal and electrical characteristics of the final material. The objective of this study is to correlate rheological, chromatographic and thermal analysis of phenolic and furfuryl resins, aiming their use as raw materials in carbon/carbon composite and glassy carbon processing. The obtained results are correlated and used directly in the establishment of the adequate parameters for carbon reinforcement impregnation and to prepare glassy carbon samples with controlled porosity.

  15. Are flowable resin-based composites a reliable material for metal orthodontic bracket bonding?

    Science.gov (United States)

    Pick, Bárbara; Rosa, Vinícius; Azeredo, Tatiana Rocha; Cruz Filho, Eduardo Augusto Mascarenhas; Miranda, Walter Gomes

    2010-07-01

    To compare the tensile bond strength (TBS) and adhesive remnant index (ARI) of three flowable resin-based composites and three orthodontic adhesive systems for metal bracket bonding. Sixty bovine incisors were randomly divided into six groups. Enamel surfaces were etched with 37 percent phosphoric acid for 30 seconds and stainless steel orthodontic brackets were bonded using either flowable resin-based composites (3M Flow, FL; Tetric Flow, TF; and Wave, WA) or orthodontic bonding systems (Transbond XT, TX; Concise Orthodontic, CO; Fill Magic Ortodôntico, FM). All specimens were thermal cycled and stored in distilled water at 37°C for 24 hours, after which they were subsequently tested for TBS using a universal testing machine. ARI scores were determined after the failure of brackets. TBS and ARI data were submitted to ANOVA, Tukey, and Kruskal-Wallis tests (p=0.05), respectively. Rankings of the resin-based composites based on TBS means (MPa) were TX (6.4 ± 2.1), followed by CO (4.5 ± 2.7), FM (3.7 ± 1.2), FL (3.6 ± 1.2), TF (3.3 ± 1.2), and WA (2.4 ± 0.6). CO exhibited the lowest ARI mean score (0.9 ± 1.2) which was significantly different from the other five materials: TX (2.8 ± 0.42), FM (2.8 ± 0.42), FL (2.9 ± 0.32), TF (2.9 ± 0.32), and WA (3.0 ± 0.01). However, there were no statistically significant differences among the other groups with mean scores of 2.8-3.0. A score of 3.0 indicated that all the resin remained bonded to the tooth surface. The flowable resin-based composites tested (Fl, TF, and WA) used to bond metal orthodontic brackets to bovine enamel had low mean TBS values but acceptable ARI mean scores. Flowable composites may not be appropriate for bracket bonding, unless the teeth to be bonded are not subjected to higher orthodontic stresses, such as those without an antagonist.

  16. A practice-based evaluation of the handling of a new self-adhesive universal resin luting material.

    Science.gov (United States)

    Burke, F J Trevor; Crisp, Russell J; Richter, B

    2006-06-01

    Ease of handling of materials may be considered helpful to achieving good results. The handling properties of a new self-adhesive universal resin luting material were tested in clinical use. Thirteen practitioners were selected at random from the Product Research and Evaluation by Practitioners (PREP) Panel, a United Kingdom-based group of dental practitioners prepared to complete evaluations of new materials and techniques in the practice environment. Explanatory letters, questionnaires and packs of the luting material were sent to the evaluators. The practitioners were asked to use the material and return the questionnaire. 144 restorations were placed using the new self-adhesive resin luting material, which was rated higher by the evaluators for ease of use (4.7 on a visual analogue scale where 5 represented easy to use and 1 represented difficult to use) than both the pre-trial resin-based and 'conventional' luting materials (rated 3.7 and 4.4 respectively on the same scale). The presentation, instructions, convenience of dispensing and handling and viscosity also received high ratings. The new material achieved ratings for ease of use superior to the pre-study resin-based and conventional luting materials in the dental practices of 13 UK dental practitioners.

  17. High irradiance curing and anomalies of exposure reciprocity law in resin-based materials.

    Science.gov (United States)

    Hadis, M; Leprince, J G; Shortall, A C; Devaux, J; Leloup, G; Palin, W M

    2011-08-01

    The aim of this work was to investigate the effect of high irradiance curing on resultant degree of conversion of 'flowable' resin composites and their counterpart higher viscosity paste materials. Five commercial flowable materials (Venus; Heraeus Kulzer, Synergy D6; Coltene, Premise; Kerr, Grandio; Voco and Gradia; GC Corp) and their counterpart higher viscosity restorative versions were tested. Specimens were cured with a halogen Swiss Master Light (EMS, Switzerland) using five different curing protocols with similar radiant exposure (18J/cm(2)): 400mW/cm(2) for 45s, 900mW/cm(2) for 20s, 1500mW/cm(2) for 12s, 2000mW/cm(2) for 9s and 3000mW/cm(2) for 6s. Degree of conversion (DC) was measured in real time by Fourier transform near infrared spectroscopy (FT-NIRS). Three- and subsequent two way ANOVA testing revealed significant differences (p≤0.02) with respect to "composite type" and "cure protocol" for DC for all 5 product comparisons. Supplementary one-way ANOVA also revealed significant differences between curing protocols (pGrandio (41±0.36 and 62±1.15%, respectively) and Venus (44±0.44 and 67±0.44%, respectively). Conversely, other flowable materials exhibited little or no significant differences between curing modes. Generally, a higher degree of conversion was observed for flowables compared with their more viscous counterpart, except at high irradiance for those materials where a reciprocal relationship with exposure time was not observed. The validity of exposure reciprocity law and final degree of conversion depends on several factors, amongst which resin viscosity and filler content were important. Practitioners should be aware of the importance of resin composite constituents and irradiation protocols. Information on material composition and appropriate radiation sources by manufacturers may assist practitioners with the selection of appropriate curing protocols for specific material/light curing unit combinations with the aim of reducing the

  18. Evaluation of material properties determining the moisture transfer

    Directory of Open Access Journals (Sweden)

    Vestfálova M.

    2013-04-01

    Full Text Available Due to solution the problems of moisture transfer is necessary to deal with two mechanisms of transfer: the molecular mass transfer and mass transfer by convection. Transfer driving force is the difference of concentrations of moisture, respectively the difference of partial vapour pressure. For molecular transfer is deciding value the coefficient of diffusivity, i.e. the property of the material. For mass transfer by convection is deciding the convection mass transfer coefficient, which depends on many parameters, but for one particular arrangement of the experiment will be influenced primarily velocity of the flow. Experimentally detectable is the overall moisture transfer caused by both mechanisms, i.e. the overall moisture transfer coefficient. Our goal was to attempt to evaluate the value of coefficient of diffusivity of some materials from the set of measured date. The date was obtained in different modes on different samples of materials. The next goal was to evaluate the dependence of the convection mass transfer coefficient on the speed of flow for the experiment alignment.

  19. Evaluation of ABS resin disk certified reference materials for heavy metal analysis by x-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Ohata, Masaki; Kidokoro, Toshihiro; Kurahashi, Masayasu; Hioki, Akiharu

    2010-01-01

    ABS resin disk certified reference materials (CRMs) for heavy-metal analysis (NMIJ CRM 8105-a, NMIJ CRM 8106-a, NMIJ CRM 8115-a and NMIJ CRM 8116-a) were evaluated using an energy dispersive X-ray fluorescence (ED-XRF) analysis. The homogeneities of elements for both among-disks and within-disk were evaluated by ED-XRF analysis without any sample pre-treatment, which were similar to those evaluated by ICP-MS analysis after a sample digenstion procedure. The normalized XRF sensitivities for Cd, Cr and Pb in different ABS resin disk CRMs were compared, and the differences among them for those ABS resin disks that have similar matrices were observed. Moreover, Hg in those ABS resin disk CRMs was stable for long-term X-ray irradiation during ED-XRF analysis. (author)

  20. Natural convection heat transfer enhancement using Microencapsulated Phase-Change-Material slurries

    International Nuclear Information System (INIS)

    Kubo, Shinji; Akino, Norio; Tanaka, Amane; Nakano, Fumihiko; Nagashima, Akira.

    1997-01-01

    The present study investigates natural convection heat transfer from a heated cylinder cooled by a water slurry of Microencapsulated Phase Change Material (MCPCM). A normal paraffin hydrocarbon with carbon number of 18 and melting point of 27.9degC, is microencapsulated by Melamine resin into particles of which average diameter is 9.5μm and specific weight is same as water. The slurry of the MCPCM and water is put into a test apparatus, which is a rectangular enclosure with a heated horizontal cylinder. As the concentrations of PCM in the slurry are changed in 1,3 and 5%, the heat transfer coefficients of the cylinder are larger than that of water as working fluid, by 3,20 and 35% enhancements respectively. (author)

  1. Use of Resin-Based Provisional Material to Create the Posterior Palatal Seal in Complete Denture Definitive Impressions.

    Science.gov (United States)

    de Souza Batista, Victor Eduardo; Vechiato-Filho, Aljomar José; Pellizzer, Eduardo Piza; Verri, Fellippo Ramos

    2017-11-17

    The purpose of this article was to present an alternative procedure using resin-based provisional material to create the posterior palatal seal (PPS). This method offers more practicality in clinical routine and increased control for addition of material to create the PPS when compared to traditional techniques such as the use of impression wax. © 2017 by the American College of Prosthodontists.

  2. The impact of resin-coating on sub-critical crack extension in a porcelain laminate veneer material.

    Science.gov (United States)

    Cao, Xu; Fleming, Garry J P; Addison, Owen

    2017-05-01

    Characterisation of the interaction between crack extension, crack stabilisation and stress/strain relaxation in the polymeric matrix, the interplay between stress corrosion cracking and the mechanical response of a resin-based luting adhesive within a surface defect population could extend PLV restoration longevity by optimising cementation protocols. The aim was to investigate the influence of stress corrosion cracking and the viscoelastic behaviour of a resin-based luting adhesive independently by controlling the environmental conditions operative during test specimen fabrication. The effects of stress corrosion at ceramic crack tips and potential viscoelastic responses to loading of the resin-coated impregnating cracks were isolated. Resin-coated feldspathic ceramic test specimens were fabricated in ambient humidity or following moisture exclusion. Bi-axial flexure strengths of groups (n = 20) were determined at constant loading rates of 2.5, 10, 40, 160 or 640 N/min and data was compared with uncoated controls. Fractographic analyses were performed on all fractured test specimens. Resin-cement coating resulted in significant ceramic strengthening in all conditions tested (p resin- coating significantly increased mean BFS (ptests identified that moisture exclusion resulted in significant increases in BFS values only at intermediate loading rates with no significant differences observed at either the fastest or slowest loading rates (640 and 2.5 N/min, respectively). Mechanical reinforcement of PLV materials by resin-cement systems is yet to be optimized. The viscoelastic behavior of the resin-cement itself can influence the magnitude of reinforcement observed and sub-critical crack growth. Copyright © 2017 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  3. Low Temperature Mechanical Testing of Carbon-Fiber/Epoxy-Resin Composite Materials

    Science.gov (United States)

    Nettles, Alan T.; Biss, Emily J.

    1996-01-01

    The use of cryogenic fuels (liquid oxygen and liquid hydrogen) in current space transportation vehicles, in combination with the proposed use of composite materials in such applications, requires an understanding of how such materials behave at cryogenic temperatures. In this investigation, tensile intralaminar shear tests were performed at room, dry ice, and liquid nitrogen temperatures to evaluate the effect of temperature on the mechanical response of the IM7/8551-7 carbon-fiber/epoxy-resin system. Quasi-isotropic lay-ups were also tested to represent a more realistic lay-up. It was found that the matrix became both increasingly resistant to microcracking and stiffer with decreasing temperature. A marginal increase in matrix shear strength with decreasing temperature was also observed. Temperature did not appear to affect the integrity of the fiber-matrix bond.

  4. Mechanical properties of resin-ceramic CAD/CAM restorative materials.

    Science.gov (United States)

    Awada, Abdallah; Nathanson, Dan

    2015-10-01

    The recent development of polymer-based computer-aided design and computer-aided manufactured (CAD/CAM) milling blocks and the limited availability of independent studies on these materials make it pertinent to evaluate their properties and identify potential strengths and limitations. The purpose of this in vitro study was to determine and compare mechanical properties (flexural strength, flexural modulus, modulus of resilience) and compare the margin edge quality of recently introduced polymer-based CAD/CAM materials with some of their commercially available composite resin and ceramic counterparts. The materials studied were Lava Ultimate Restorative (LVU; 3M ESPE), Enamic (ENA; Vita Zahnfabrik), Cerasmart (CES; GC Dental Products), IPS Empress CAD (EMP; Ivoclar Vivadent AG), Vitablocs Mark II (VM2; Vita Zahnfabrik), and Paradigm MZ100 Block (MZ1; 3M ESPE). Polished 4×1×13.5 mm bars (n=25) were prepared from standard-sized milling blocks of each tested material. The bars were subjected to a 3-point flexural test on a 10-mm span with a crosshead speed of 0.5 mm/min. In addition, 42 conventional monolithic crowns (7 per material) were milled. Margin edge quality was observed by means of macrophotography and optical microscopy, providing a qualitative visual assessment and a measurement of existing roughness. The results were analyzed by ANOVA followed by the Tukey HSD test (α=.05). The mean flexural strength of the tested materials ranged from 105 ±9 MPa (VM2) to 219 ±20 MPa (CES). The mean flexural modulus ranged from 8 ±0.25 GPa (CES) to 32 ±1.9 GPa (EMP). The mean modulus of resilience ranged from 0.21 ±0.02 MPa (VM2) to 3.07 ±0.45 MPa (CES). The qualitative assessment of margin edge roughness revealed visible differences among the tested materials, with mean roughness measurements ranging from 60 ±16 μm (CES) to 190 ±15 μm (EMP). The material factor had a significant effect on the mean flexural strength (Pmaterials tested in this study exhibited

  5. Simulating Resin Infusion through Textile Reinforcement Materials for the Manufacture of Complex Composite Structures

    Directory of Open Access Journals (Sweden)

    Robert S. Pierce

    2017-10-01

    Full Text Available Increasing demand for weight reduction and greater fuel efficiency continues to spur the use of composite materials in commercial aircraft structures. Subsequently, as composite aerostructures become larger and more complex, traditional autoclave manufacturing methods are becoming prohibitively expensive. This has prompted renewed interest in out-of-autoclave processing techniques in which resins are introduced into a reinforcing preform. However, the success of these resin infusion methods is highly dependent upon operator skill and experience, particularly in the development of new manufacturing strategies for complex parts. Process modeling, as a predictive computational tool, aims to address the issues of reliability and waste that result from traditional trial-and-error approaches. Basic modeling attempts, many of which are still used in industry, generally focus on simulating fluid flow through an isotropic porous reinforcement material. However, recent efforts are beginning to account for the multiscale and multidisciplinary complexity of woven materials, in simulations that can provide greater fidelity. In particular, new multi-physics process models are able to better predict the infusion behavior through textiles by considering the effect of fabric deformation on permeability and porosity properties within the reinforcing material. In addition to reviewing previous research related to process modeling and the current state of the art, this paper highlights the recent validation of a multi-physics process model against the experimental infusion of a complex double dome component. By accounting for deformation-dependent flow behavior, the multi-physics process model was able to predict realistic flow behavior, demonstrating considerable improvement over basic isotropic permeability models.

  6. Flame retardant materials based on BDM/DBA resin and organic-inorganic additives

    OpenAIRE

    Wang, Zheng

    2017-01-01

    2,2’-diallyl bisphenol A (DBA) modified bismaleimide resins (BDM) are widely used as polymer matrix of high-performance composites in the field of aerospace, transportation, machinery, and electronics. This kind of resin has excellent properties, including good thermal stability, good processing performance, high mechanical strength, excellent dielectric properties, etc. However, as for most organic resins, the flame retardancy of the BMI resins is not so good. In order to expand the use of t...

  7. Effect of light sources on the bond strength of resin material to thin-walled roots.

    Science.gov (United States)

    Machado, Rosângela Paniago; Chaves, Carolina de Andrade Lima; Rached-Junior, Fuad Jacob Abi; de Souza, Cassio José; Messias, Danielle Cristine; Silva-Sousa, Yara Corrêa

    2014-01-01

    The aim of this study was to evaluate the bond strength to the dentin of an adhesive material used for root reinforcement light activated with different sources. Roots were divided into 4 groups (n=15) according to the light source used to activate the resin reinforcement: GI, non-weakened roots (control); GII, halogen light (H) 600 mW/cm²; GIII, LED 800 mW/cm² and GIV, LED 1500 mW/cm². The reinforcement was done with adhesive, composite resin and fiberglass posts. After 24 h, the specimens were sectioned and the first slice of each post region was used in the push out test in a universal testing machine with a crosshead speed of 0.5 mm/min. Failure modes of the debonded specimens were examined. Data (MPa) were analyzed by ANOVA and Holm-Sidak test (α=0.05). The second slice from each region was analyzed by scanning electron microscopy (SEM). LED-1500 (4.69 ± 1.74) provided bond strength similar to the control group (5.05 ± 2.63) and statistically different from H-600 (1.96 ± 0.94) and LED-800 (2.75 ± 1.90), which were similar to each other (presin reinforcement to the dentin.

  8. Bacterial colonization of resin composite cements: influence of material composition and surface roughness.

    Science.gov (United States)

    Glauser, Stephanie; Astasov-Frauenhoffer, Monika; Müller, Johannes A; Fischer, Jens; Waltimo, Tuomas; Rohr, Nadja

    2017-08-01

    So-called secondary caries may develop in the cement gap between the tooth and the bonded restoration. Cement materials with a low susceptibility to biofilm formation are therefore desirable. In the present study, the adhesion of Strepococcus mutans onto three adhesive (Multilink Automix, RelyX Ultimate, and Panavia V5) and three self-adhesive (Multilink Speed Cem, RelyX Unicem 2 Automix, and Panavia SA plus) resin composite cements was evaluated. Previous studies have failed to evaluate concomitantly the effect of both the composition of the cements and their surface roughness on biofilm formation. The presence of S. mutans on cement surfaces with differing degrees of roughness was therefore recorded using fluorescence microscopy and crystal violet staining, and the composition of the cements was analyzed using energy-dispersive X-ray spectroscopy mapping. Biofilm formation on resin composite cements was found to be higher on rougher surfaces, implying that adequate polishing of the cement gap is essential. The use of copper-containing cements (Multilink Automix, Panavia V5, and Panavia SA plus) significantly reduced biofilm formation. © 2017 Eur J Oral Sci.

  9. Randomized clinical trial of two resin-modified glass ionomer materials: 1-year results.

    Science.gov (United States)

    Perdigão, J; Dutra-Corrêa, M; Saraceni, S H C; Ciaramicoli, M T; Kiyan, V H

    2012-01-01

    With institutional review board approval, 33 patients who needed restoration of noncarious cervical lesions (NCCL) were enrolled in this study. A total of 92 NCCL were selected and randomly assigned to three groups: (1) Ambar (FGM), a two-step etch-and-rinse adhesive (control), combined with the nanofilled composite resin Filtek Supreme Plus (FSP; 3M ESPE); (2) Fuji II LC (GC America), a traditional resin-modified glass ionomer (RMGIC) restorative material; (3) Ketac Nano (3M ESPE), a nanofilled RMGIC restorative material. Restorations were evaluated at six months and one year using modified United States Public Health Service parameters. At six months after initial placement, 84 restorations (a 91.3% recall rate) were evaluated. At one year, 78 restorations (a 84.8% recall rate) were available for evaluation. The six month and one year overall retention rates were 93.1% and 92.6%, respectively, for Ambar/FSP; 100% and 100%, respectively, for Fuji II LC; and 100% and 100%, respectively, for Ketac Nano with no statistical difference between any pair of groups at each recall. Sensitivity to air decreased for all three adhesive materials from the preoperative to the postoperative stage, but the difference was not statistically significant. For Ambar/FSP, there were no statistical differences for any of the parameters from baseline to six months and from baseline to one year. For Fuji II LC, surface texture worsened significantly from baseline to six months and from baseline to one year. For Ketac Nano, enamel marginal staining increased significantly from baseline to one year and from six months to one year. Marginal adaptation was statistically worse at one year compared with baseline only for Ketac Nano. When parameters were compared for materials at each recall, Ketac Nano resulted in significantly worse color match than any of the other two materials at any evaluation period. At one year, Ketac Nano resulted in significantly worse marginal adaptation than the

  10. Synthesis, Transfer, and Characterization of Nanoscale 2-Dimensional Materials

    Science.gov (United States)

    2015-09-01

    stack is floating on top of the DDI water surface. Instead of removing the stack with the target substrate, a graphene/copper foil substrate (graphene...demonstrated the synthesis of graphene, hexagonal boron nitride, and bismuth telluride using chemical and physical vapor deposition techniques. Making...for material synthesis, transfer, and characterization. 15. SUBJECT TERMS graphene, hexagonal boron nitride, bismuth telluride, synthesis, transfer

  11. Theory of light transfer in food and biological materials

    Science.gov (United States)

    In this chapter, we first define the basic radiometric quantities that are needed for describing light propagation in food and biological materials. Radiative transfer theory is then derived, according to the principle of the conservation of energy. Because the radiative transfer theory equation is ...

  12. Issues related to the inter-utility transfer of material

    International Nuclear Information System (INIS)

    1993-08-01

    An option that utilities have for obtaining material is to procure the desired item(s) from another utility. There are several reasons utilities choose another utility as the procurement source including item obsolescence, prohibitive cost on the commercial market, and excessive lead time. This document provides information on the technical, quality, and commercial issues which utilities may need to address when selling material to or procuring material from other utilities. This report provides suggested approaches for each of the following technical and quality issues: Design considerations; item acceptability considerations; original supplier considerations; commercial grade item dedication considerations; reportability considerations; packaging, shipping, and storage considerations; documentation considerations; receipt inspection considerations. The information is provided primarily for the inter-utility transfer of safety-related material. Several of the topics, however, may also apply to the transfer of non-safety-related material. The report also provides considerations on commercial issues which may be addressed during the inter-utility transfer of materials

  13. Research Tools and Materials | NCI Technology Transfer Center | TTC

    Science.gov (United States)

    Research Tools can be found in TTC's Available Technologies and in scientific publications. They are freely available to non-profits and universities through a Material Transfer Agreement (or other appropriate mechanism), and available via licensing to companies.

  14. Effect of Aging Regimens on Resin Nanoceramic Chairside CAD/CAM Material.

    Science.gov (United States)

    Al-Harbi, Fahad A; Ayad, Neveen M; ArRejaie, Aws S; Bahgat, Hala A; Baba, Nadim Z

    2017-07-01

    To evaluate the effect of cyclic mechanical loading, thermal cycling, and storage in water on a resin nanoceramic chairside computer-aided designed/computer-aided manufactured (CAD/CAM) material compared to a control leucite-reinforced glass-ceramic material. One hundred twenty specimens (18 × 4 × 3 mm) were milled from two chairside CAD/CAM materials' blocks (Lava Ultimate: LU; Vitablock Mark II: VM). Each group included four subgroups (A: n = 20 control; B: n = 20 cyclic loading [105 cycles, 80 N]; C: n = 20 thermal cycling [5 to 55°C]; D: n = 60 water storage [20: 3 months; 20: 6 months; 20: 9 months at 37°C]). Each subgroup included 10 specimens tested for flexure strength using three-point bending in a universal testing machine. The other 10 specimens were tested for surface roughness using an automated profiler followed by testing for surface hardness using a microhardness tester. LU displayed higher flexure strength than VM before and after all the aging conditions. The surface roughness for VM was lower than LU for the control, but both materials showed comparable values and significant increases after 9 months storage in water. After cyclic loading, only VM displayed a significant increase in the surface roughness value (p CAD/CAM material. © 2015 by the American College of Prosthodontists.

  15. Light-curing considerations for resin-based composite materials: a review. Part II.

    Science.gov (United States)

    Malhotra, Neeraj; Mala, Kundabala

    2010-10-01

    As discussed in Part I, the type of curing light and curing mode impact the polymerization kinetics of resin-based composite (RBC) materials. Major changes in light-curing units and curing modes have occurred. The type of curing light and mode employed affects the polymerization shrinkage and associated stresses, microhardness, depth of cure, degree of conversion, and color change of RBCs. These factors also may influence the microleakage in an RBC restoration. Apart from the type of unit and mode used, the polymerization of RBCs is also affected by how a light-curing unit is used and handled, as well as the aspects associated with RBCs and the environment. Part II discusses the various clinical issues that should be considered while curing RBC restorations in order to achieve the best possible outcome.

  16. Field Trial of Resin-Based Composite Materials for the Treatment of Surface Collapses Associated with Former Shallow Coal Mining

    OpenAIRE

    Philip T. Broughton; Mark P. Bettney; Isla L. Smail

    2016-01-01

    Effective treatment of ground instability is essential when managing the impacts associated with historic mining. A field trial was undertaken by the Coal Authority to investigate the geotechnical performance and potential use of composite materials comprising resin and fill or stone to safely treat surface collapses, such as crown-holes, associated with shallow mining. Test pits were loosely filled with various granular fill materials. The fill material was injected with commercially availab...

  17. Restoration of endodontically treated anterior teeth: an evaluation of coronal microleakage of glass ionomer and composite resin materials.

    Science.gov (United States)

    Diaz-Arnold, A M; Wilcox, L R

    1990-12-01

    A glass ionomer material was evaluated for coronal microleakage in permanent lingual access restorations of endodontically treated anterior teeth. The material was tested as a restoration, placed over a zinc oxide-eugenol base, and as a base with an acid-etched composite resin veneer and a dentinal bonding agent. Restored teeth were thermocycled, immersed in silver nitrate, developed, and sectioned to assess microleakage. Significant coronal leakage was observed with all materials used.

  18. Effect of toothbrushing abrasion on weight and surface roughness of pH-cycled resin cements and indirect restorative materials.

    Science.gov (United States)

    Prakki, Anuradha; Cilli, Renato; de Araújo, Paulo Amarante; Navarro, Maria Fidela de Lima; Mondelli, José; Mondelli, Rafael Francisco Lia

    2007-10-01

    To evaluate wear resistance, by weight loss and roughness changes, of resin cements and indirect restorative materials to toothbrushing and toothbrushing associated with pH-challenge simulation. The following materials were studied: Enforce resin cement (Dentsply), Rely X resin cement (3M ESPE), Variolink II resin cement (Ivoclar/Vivadent), Artglass indirect resin composite (Heraeus Kulzer), and Duceram Plus porcelain (Degussa). Twenty cylindrical specimens were prepared for each material for a total of 10 groups (n = 10). After finishing and polishing, the specimens were subjected to toothbrushing. One group of each material was pH cycled before abrasion. For toothbrushing, a machine containing soft-bristle tips, dentifrice, and water was used. One hundred thousand brushing cycles were performed. Weight loss was determined as the percentage difference between initial (before brushing) and final (after brushing) measurements. Roughness changes were evaluated by the difference between initial and final measurements. Data were analyzed with the paired t test, 2-way ANOVA, and Tukey test (alpha = 0.05). Paired t test showed significant differences in weight loss and roughness after toothbrushing (P <.01). Statistically significant differences were found among materials for both weight loss, which ranged from 0.34% (Duceram Plus) to 1.85% (Enforce/pH), and roughness changes, which ranged from -0.03 microm (Duceram Plus) to 0.29 microm (Rely X/pH). Among cements, Variolink II exhibited the least weight loss and roughness increase. Of all materials, Duceram Plus porcelain presented the lowest weight loss and became smoother after abrasion. pH cycling had no influence on material weight or roughness changes after abrasion.

  19. Effect of storage in water and thermocycling on hardness and roughness of resin materials for temporary restorations

    Directory of Open Access Journals (Sweden)

    Jerusa Cleci de Oliveira

    2010-09-01

    Full Text Available PURPOSE: This study evaluated the effect of storage in water and thermocycling on hardness and roughness of resin materials for temporary restorations. MATERIAL AND METHODS: Three acrylic resins (Dencor-De, Duralay-Du, and Vipi Cor-VC were selected and one composite resin (Opallis-Op was used as a parameter for comparison. The materials were prepared according to the manufacturers' instructions and were placed in stainless steel moulds (20 mm in diameter and 5 mm thick. Thirty samples of each resin were made and divided into three groups (n = 10 according to the moment of Vickers hardness (VHN and roughness (Ra analyses: C (control group: immediately after specimen preparation; Sw: after storage in distilled water at 37 °C for 24 hours; Tc: after thermocycling (3000 cycles; 5-55 °C, 30 seconds dwell time. Data were submitted to 2-way ANOVA followed by Tukey's test (α = 0.05. RESULTS: Op resin had higher surface hardness values (p 0.05 in roughness among materials (De = 0.31 ± 0.07; Du = 0.51 ± 0.20; VC = 0.41 ± 0.15; Op = 0.42 ± 0.18. Storage in water did not change hardness and roughness of the tested materials (p > 0.05. There was a significant increase in roughness after thermocycling (p < 0.05, except for material Du, which showed no significant change in roughness in any evaluated period (p = 0.99. CONCLUSION: Thermocycling increased the roughness in most tested materials without affecting hardness, while storage in water had no significant effect in the evaluated properties.

  20. Do Dental Resin Composites Accumulate More Oral Biofilms and Plaque than Amalgam and Glass Ionomer Materials?

    Science.gov (United States)

    Zhang, Ning; Melo, Mary A.S.; Weir, Michael D.; Reynolds, Mark A.; Bai, Yuxing; Xu, Hockin H.K.

    2016-01-01

    A long-time drawback of dental composites is that they accumulate more biofilms and plaques than amalgam and glass ionomer restorative materials. It would be highly desirable to develop a new composite with reduced biofilm growth, while avoiding the non-esthetics of amalgam and low strength of glass ionomer. The objectives of this study were to: (1) develop a protein-repellent composite with reduced biofilms matching amalgam and glass ionomer for the first time; and (2) investigate their protein adsorption, biofilms, and mechanical properties. Five materials were tested: A new composite containing 3% of protein-repellent 2-methacryloyloxyethyl phosphorylcholine (MPC); the composite with 0% MPC as control; commercial composite control; dental amalgam; resin-modified glass ionomer (RMGI). A dental plaque microcosm biofilm model with human saliva as inoculum was used to investigate metabolic activity, colony-forming units (CFU), and lactic acid production. Composite with 3% MPC had flexural strength similar to those with 0% MPC and commercial composite control (p > 0.1), and much greater than RMGI (p control composites (p control composites (p 0.1). In conclusion, a new protein-repellent dental resin composite reduced oral biofilm growth and acid production to the low levels of non-esthetic amalgam and RMGI for the first time. The long-held conclusion that dental composites accumulate more biofilms than amalgam and glass ionomer is no longer true. The novel composite is promising to finally overcome the major biofilm-accumulation drawback of dental composites in order to reduce biofilm acids and secondary caries. PMID:28774007

  1. Do Dental Resin Composites Accumulate More Oral Biofilms and Plaque than Amalgam and Glass Ionomer Materials?

    Science.gov (United States)

    Zhang, Ning; Melo, Mary A S; Weir, Michael D; Reynolds, Mark A; Bai, Yuxing; Xu, Hockin H K

    2016-11-01

    A long-time drawback of dental composites is that they accumulate more biofilms and plaques than amalgam and glass ionomer restorative materials. It would be highly desirable to develop a new composite with reduced biofilm growth, while avoiding the non-esthetics of amalgam and low strength of glass ionomer. The objectives of this study were to: (1) develop a protein-repellent composite with reduced biofilms matching amalgam and glass ionomer for the first time; and (2) investigate their protein adsorption, biofilms, and mechanical properties. Five materials were tested: A new composite containing 3% of protein-repellent 2-methacryloyloxyethyl phosphorylcholine (MPC); the composite with 0% MPC as control; commercial composite control; dental amalgam; resin-modified glass ionomer (RMGI). A dental plaque microcosm biofilm model with human saliva as inoculum was used to investigate metabolic activity, colony-forming units (CFU), and lactic acid production. Composite with 3% MPC had flexural strength similar to those with 0% MPC and commercial composite control ( p > 0.1), and much greater than RMGI ( p biofilm CFU and lactic acid much lower than control composites ( p Biofilm growth, metabolic activity and lactic acid on the new composite with 3% MPC were reduced to the low level of amalgam and RMGI ( p > 0.1). In conclusion, a new protein-repellent dental resin composite reduced oral biofilm growth and acid production to the low levels of non-esthetic amalgam and RMGI for the first time. The long-held conclusion that dental composites accumulate more biofilms than amalgam and glass ionomer is no longer true. The novel composite is promising to finally overcome the major biofilm-accumulation drawback of dental composites in order to reduce biofilm acids and secondary caries.

  2. Do Dental Resin Composites Accumulate More Oral Biofilms and Plaque than Amalgam and Glass Ionomer Materials?

    Directory of Open Access Journals (Sweden)

    Ning Zhang

    2016-11-01

    Full Text Available A long-time drawback of dental composites is that they accumulate more biofilms and plaques than amalgam and glass ionomer restorative materials. It would be highly desirable to develop a new composite with reduced biofilm growth, while avoiding the non-esthetics of amalgam and low strength of glass ionomer. The objectives of this study were to: (1 develop a protein-repellent composite with reduced biofilms matching amalgam and glass ionomer for the first time; and (2 investigate their protein adsorption, biofilms, and mechanical properties. Five materials were tested: A new composite containing 3% of protein-repellent 2-methacryloyloxyethyl phosphorylcholine (MPC; the composite with 0% MPC as control; commercial composite control; dental amalgam; resin-modified glass ionomer (RMGI. A dental plaque microcosm biofilm model with human saliva as inoculum was used to investigate metabolic activity, colony-forming units (CFU, and lactic acid production. Composite with 3% MPC had flexural strength similar to those with 0% MPC and commercial composite control (p > 0.1, and much greater than RMGI (p < 0.05. Composite with 3% MPC had protein adsorption that was only 1/10 that of control composites (p < 0.05. Composite with 3% MPC had biofilm CFU and lactic acid much lower than control composites (p < 0.05. Biofilm growth, metabolic activity and lactic acid on the new composite with 3% MPC were reduced to the low level of amalgam and RMGI (p > 0.1. In conclusion, a new protein-repellent dental resin composite reduced oral biofilm growth and acid production to the low levels of non-esthetic amalgam and RMGI for the first time. The long-held conclusion that dental composites accumulate more biofilms than amalgam and glass ionomer is no longer true. The novel composite is promising to finally overcome the major biofilm-accumulation drawback of dental composites in order to reduce biofilm acids and secondary caries.

  3. Resin-Impregnated Carbon Ablator: A New Ablative Material for Hyperbolic Entry Speeds

    Science.gov (United States)

    Esper, Jaime; Lengowski, Michael

    2012-01-01

    Ablative materials are required to protect a space vehicle from the extreme temperatures encountered during the most demanding (hyperbolic) atmospheric entry velocities, either for probes launched toward other celestial bodies, or coming back to Earth from deep space missions. To that effect, the resin-impregnated carbon ablator (RICA) is a high-temperature carbon/phenolic ablative thermal protection system (TPS) material designed to use modern and commercially viable components in its manufacture. Heritage carbon/phenolic ablators intended for this use rely on materials that are no longer in production (i.e., Galileo, Pioneer Venus); hence the development of alternatives such as RICA is necessary for future NASA planetary entry and Earth re-entry missions. RICA s capabilities were initially measured in air for Earth re-entry applications, where it was exposed to a heat flux of 14 MW/sq m for 22 seconds. Methane tests were also carried out for potential application in Saturn s moon Titan, with a nominal heat flux of 1.4 MW/sq m for up to 478 seconds. Three slightly different material formulations were manufactured and subsequently tested at the Plasma Wind Tunnel of the University of Stuttgart in Germany (PWK1) in the summer and fall of 2010. The TPS integrity was well preserved in most cases, and results show great promise.

  4. Preparation of polymer nanocomposite materials based on unsaturated polyester resin and nanosilica A200. Part II - Structural and properties of polymer nanocomposite materials based on unsaturated polyester resin and nanosilica A200 with coupling agent

    International Nuclear Information System (INIS)

    Trinh Minh Dat; Bui Chuong; Bach Trong Phuc; Dinh Van Kai; Luu Van Khue

    2012-01-01

    Effects of coupling agent on the structures and properties of nanocomposite materials based on unsaturated polyester resin and A200 silica nanoparticles were investigated. The viscosity of the resin/A200 silica mixtures increased with increasing coupling agent content because of forming core-shell structures and the mechanical properties of polymer nanocomposites generally were better than those without coupling agent and appeared a maximum in mechanical properties at 4.0 wt% coupling agent content. IR analyze indicated that the coupling agent had reacted with unsaturated polyester resin and A200 silica nanoparticles. SEM, Fe-SEM and TG-SDC demonstrated more homogeneous dispersion of A200 silica nanoparticles in the polymer matrix and accompanied by lower glass transition temperature and melt temperature. Furthermore, it was also found that the best dispersion route involved a methanol dispersion technique. (author)

  5. On material transfer agreements and visibility of researchers in biotechnology

    NARCIS (Netherlands)

    Rodriguez, V.F.; Janssens, Frizo; Debackere, Koenraad; De Moor, Bart

    2008-01-01

    When carrying out a research project, some materials may not be available in-house. Thus, investigators resort to external providers for conducting their research. To that end, the exchange may be formalised through material transfer agreements. In this context, industry, government and academia

  6. Solidification of spent ion exchange resin using new cementitious material, (1)

    International Nuclear Information System (INIS)

    Matsuda, Masami; Nishi, Takashi; Chino, Koichi; Kikuchi, Makoto

    1992-01-01

    Cement solidification is a conventional technique to solidify spent ion exchange resin. Swelling property of the ion exchange resin was investigated theoretically and experimentally, as the first step to improve resin content in a cement package. Swelling pressure of the resin was first formulated based on Gregor's swelling model. It was shown that the pressure depended on such factors as ion exchange capacity, type of functional group, crosslinkage and water content. Subsequently, swelling pressures for over forty properties of cation exchange resin (DIAION SK-series) with different exchange capacities, water contents and others were experimentally evaluated using an originally developed method. The pressure changed over a range of 0 ∼ 60 MPa, depending on properties of the ion exchange resin. These results were in close agreement with values calculated by Gregor's model, indicating that the swelling pressure could be evaluated without resorting to experiments. (author)

  7. Characterization of multiwalled carbon nanotube-polymethyl methacrylate composite resins as denture base materials.

    Science.gov (United States)

    Wang, Russell; Tao, Junliang; Yu, Bill; Dai, Liming

    2014-04-01

    Most fractures of dentures occur during function, primarily because of the flexural fatigue of denture resins. The purpose of this study was to evaluate a polymethyl methacrylate denture base material modified with multiwalled carbon nanotubes in terms of fatigue resistance, flexural strength, and resilience. Denture resin specimens were fabricated: control, 0.5 wt%, 1 wt%, and 2 wt% of multiwalled carbon nanotubes. Multiwalled carbon nanotubes were dispersed by sonication. Thermogravimetric analysis was used to determine quantitative dispersions of multiwalled carbon nanotubes in polymethyl methacrylate. Raman spectroscopic analyses were used to evaluate interfacial reactions between the multiwalled carbon nanotubes and the polymethyl methacrylate matrix. Groups with and without multiwalled carbon nanotubes were subjected to a 3-point-bending test for flexural strength. Resilience was derived from a stress and/or strain curve. Fatigue resistance was conducted by a 4-point bending test. Fractured surfaces were analyzed by scanning electron microscopy. One-way ANOVA and the Duncan tests were used to identify any statistical differences (α=.05). Thermogravimetric analysis verified the accurate amounts of multiwalled carbon nanotubes dispersed in the polymethyl methacrylate resin. Raman spectroscopy showed an interfacial reaction between the multiwalled carbon nanotubes and the polymethyl methacrylate matrix. Statistical analyses revealed significant differences in static and dynamic loadings among the groups. The worst mechanical properties were in the 2 wt% multiwalled carbon nanotubes (Ppolymethyl methacrylate groups showed poor fatigue resistance. The scanning electron microscopy results indicated more agglomerations in the 2% multiwalled carbon nanotubes. Multiwalled carbon nanotubes-polymethyl methacrylate groups (0.5% and 1%) performed better than the control group during the static flexural test. The results indicated that 2 wt% multiwalled carbon nanotubes

  8. Internal transfers of special nuclear material - March 1975

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    Paragraph 70.51(e) of 10 CFR Part 70 requires, with certain exceptions stated in the rule, that each licensee authorized to possess more than one effective kilogram of special nuclear material (SNM) maintain certain procedures. These procedures are to include: (1) records of the quantities of SNM added to or removed from the process; (2) documentation of all transfers of SNM between material-balance areas to show the identity and quantity of SNM transferred; (3) requirements for authorized signatures on each document used to record the transfer of SNM between material-balance areas; and (4) means for control of and accounting for internal transfer documents. Paragraph 70.58(e) requires licensees to establish, maintain, and follow a system for measuring the SNM transferred between material-balance areas and item-control areas. Paragraph 70.58(f) requires that licensees have a program that evaluates and controls the quality of their measurement system. Additionally, all licensees authorized to possess SNM must comply with paragraph 70.51(b) of 10 CFR Part 70. That rule requires licensees to keep records showing, among other things, the inventory of all SNM in their possession and its location. This guide sets forth acceptable methods for controlling and documenting transfers of SNM within a plant site in order to meet the requirements listed above

  9. Effect of surface treatments on the bond strength of soft denture lining materials to an acrylic resin denture base.

    Science.gov (United States)

    Gundogdu, Mustafa; Yesil Duymus, Zeynep; Alkurt, Murat

    2014-10-01

    Adhesive failure between acrylic resin and resilient liner material is commonly encountered in clinical practice. The purpose of this study was to evaluate the effect of different surface treatments on the bond strength of 2 different resilient lining materials to an acrylic resin denture base. Ninety-six dumbbell-shaped specimens were fabricated from heat-polymerized acrylic resin, and 3 mm of the material was cut from the thin midsection. The specimens were divided into 6 groups according to their surface treatments: no surface treatment (control group), 36% phosphoric acid etching (acid group), erbium:yttrium-aluminum-garnet (Er:YAG) laser (laser group), airborne-particle abrasion with 50-μm Al2O3 particles (abrasion group), an acid+laser group, and an abrasion+laser group. The specimens in each group were divided into 2 subgroups according to the resilient lining material used: heat-polymerized silicone based resilient liner (Molloplast B) and autopolymerized silicone-based resilient liner (Ufi Gel P). After all of the specimens had been polymerized, they were stored in distilled water at 37°C for 1 week. A tensile bond strength test was then performed. Data were analyzed with a 2-way ANOVA, and the Sidak multiple comparison test was used to identify significant differences (α=.05). The effects of the surface treatments and resilient lining materials on the surface of the denture base resin were examined with scanning electron microscopy. The tensile bond strength was significantly different between Molloplast B and Ufi Gel P (Presin. Molloplast B exhibited significantly higher bond strength than Ufi Gel P. Altering the surface of the acrylic resin denture base with 36% phosphoric acid etching increased bond strength. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  10. Low-Cost Resin Transfer Molding Process Developed for High-Temperature Polyimide Matrix Composites

    Science.gov (United States)

    1996-01-01

    The use of high-temperature polymer matrix composites (PMC's) in aircraft engine applications can significantly reduce engine weight and improve performance and fuel efficiency. High-temperature PMC's, such as those based on the PMR-15 polyimide matrix resin developed by the NASA Lewis Research Center, have been used extensively in military applications where performance improvements have justified their use regardless of the cost involved in producing the component. However, in commercial engines cost is a primary driver, and PMC components must be produced at costs comparable to those of the metal components that they will replace.

  11. Effect of reline material and denture base surface treatment on the impact strength of a denture base acrylic resin.

    Science.gov (United States)

    da Cruz Perez, Luciano Elias; Machado, Ana Lucia; Canevarolo, Sebastião Vicente; Vergani, Carlos Eduardo; Giampaolo, Eunice Teresinha; Pavarina, Ana Cláudia

    2010-03-01

    In this study, the effect of relining and surface treatment on the impact strength (IS) of a heat-polymerising denture base acrylic resin (Lucitone 550-L) was evaluated. Rectangular bars of L were made (60 x 6 x 2 mm) and relined (2 mm) with the relining resins Ufi Gel Hard (UH) and Tokuso Rebase Fast (TR). Specimens relined with L and intact L, TR and UH specimens were also made (60 x 6 x 4 mm), for comparison. Before relining, the L surface was left untreated or wetted with methyl methacrylate monomer and/or the bonding agents (BA) supplied by manufacturers of the reline resins. V-notches were machined at the midpoint of the length of all specimens. The notches were made either across the width (Nw) or across the thickness of the specimens (Nth). The Charpy impact test was performed using a 0.5-J pendulum, which had been specially designed and constructed. Data were analysed separately for each notch position using one-way analysis of variance and Tukey honestly significant difference post-hoc test (p = 0.05). The IS of L was similar to that of L/L. For the Nw notch, treating the denture base L with TR BA and relining with TR reline material produced the highest IS. The IS of specimens made from heat polymerising acrylic resin Lucitone 550 was increased after relining using the hard chairside reline resin TR with its proprietary BA.

  12. Determining the dimensional stability, fracture toughness and flexural strength of light-cured acrylic resin custom tray material.

    Science.gov (United States)

    Khan, S B; Geerts, G

    2009-06-01

    Light-cured acrylic resin custom tray material is used in commercial dental laboratories but little evidence-based scientific information on its physical properties is available. This study investigates the dimensional stability of light-cured acrylic resin custom tray material and compares its fracture toughness and flexural strength to a chemically-cured acrylic material. For dimensional stability, 20 light-cured specimens were fabricated and measured 3 times at regular time intervals over 48 hours. Mean shrinkage was calculated for each time interval and the mean values were compared to the standard using the Wilcoxon Rank Sum test. A p-value of materials with a single-edge notch were subjected to a compressive load using the 3-point bending technique. For flexural strength, 1 group (n=20) of each material was subjected to a compressive load using 3-point bending. The highest load before failure was used to calculate the fracture toughness and flexural strength. Differences in fracture toughness and flexural strength values between the 2 groups were compared using ANOVA testing. A p-value of 0.05). The fracture toughness and flexural strength were significantly higher for the light-cured material. Trays made from light-cured acrylic resin can be used immediately following polymerization. The light-cured material is more resistant to bending and crack propagation than the chemically-cured type.

  13. The Effect of Finishing and Polishing Techniques on the Surface Roughness and the Color of Nanocomposite Resin Restorative Materials.

    Science.gov (United States)

    Avsar, Aysun; Yuzbasioglu, Emir; Sarac, Duygu

    2015-01-01

    Rough, poorly polished surfaces contribute to staining, plaque accumulation, gingival irritation and recurrent caries. Finishing and polishing techniques are critical factors contributing to the longevity of the direct composite resin restorations. The aim of this in vitro study was to evaluate the effects of finishing and polishing systems on surface roughness of six nanocomposite restorative resins. Thirty specimens of each restorative material (n=180) were placed in a teflon mould (6 mm in diameter and 3 mm in depth) and cured with a LED curing unit. Six specimens from each of restorative material were randomly assigned to four groups for finishing and polishing (carbide burs, diamond burs, aluminium oxide discs, silicon rubber polisher) techniques. Mylar strip formed specimens were served as control group. After finishing and polishing procedures surface roughness was evaluated by a profilometer. The data was analyzed by 2-way analysis of variance and the Tukey HSD test (α=0.05). Significant differences were found between the groups in terms roughness (prestorative materials. Although mylar matrix strip formed surfaces presents lower surface roughness values, recountouring and polishing of resin restorations are often required in clinical situations. Aluminium oxide discs and carbide finishing burs are suitable for finishing and polishing procedures for nanocomposite restorative resins.

  14. Micro-shear bond strength of different resin cements to ceramic/glass-polymer CAD-CAM block materials.

    Science.gov (United States)

    Cekic-Nagas, Isil; Ergun, Gulfem; Egilmez, Ferhan; Vallittu, Pekka Kalevi; Lassila, Lippo Veli Juhana

    2016-10-01

    The aim of this study was to evaluate the effects of hydrofluoric acid treatment on bond strength of resin cements to three different types of ceramic/glass containing CAD-CAM block composite materials. CAD-CAM block materials of polymer infiltrated (Vita Enamic), resin nanoceramic (Lava Ultimate) and nanoceramic (Cerasmart) with a thickness of 1.5mm were randomly divided into two groups according to the surface treatment performed. In Group 1, specimens were wet-ground with silicon carbide abrasive papers up to no. 1000. In Group 2, 9.6% hydrofluoric acid gel was applied to ceramics. Three different resin cements (RelyX, Variolink Esthetic and G-CEM LinkAce) were applied to the tubes in 1.2-mm thick increments and light-cured for 40s using LED light curing unit. Half of the specimens (n=10) were submitted to thermal cycling (5000 cycles, 5-55°C). The strength measurements were accomplished with a universal testing machine (Lloyd Instruments) at a cross-head speed of 0.5mm/min until the failure occurs. Failure modes were examined using a stereomicroscope and scanning electron microscope. The data were analyzed with multivariate analysis of variance (MANOVA) and Tukey's post hoc tests (α=0.05). There were significant differences between ceramics and resin cements (pceramics (pceramic/glass-polymer materials might promote the bonding capacity of these systems. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  15. Resin-Powder Dispenser

    Science.gov (United States)

    Standfield, Clarence E.

    1994-01-01

    Resin-powder dispenser used at NASA's Langley Research Center for processing of composite-material prepregs. Dispenser evenly distributes powder (resin polymer and other matrix materials in powder form) onto wet uncured prepregs. Provides versatility in distribution of solid resin in prepreg operation. Used wherever there is requirement for even, continuous distribution of small amount of powder.

  16. Characteristics of novel root-end filling material using epoxy resin and Portland cement.

    Science.gov (United States)

    Lee, Sang-Jin; Chung, Jin; Na, Hee-Sam; Park, Eun-Joo; Jeon, Hyo-Jin; Kim, Hyeon-Cheol

    2013-04-01

    The aim of this study was to evaluate the physical properties and cytotoxicity of a novel root-end filling material (EPC) which is made from epoxy resin and Portland cement as a mineral trioxide aggregate (MTA) substitute. EPC, developed as a root-end filling material, was compared with MTA and a mixture of AH Plus sealer and MTA (AMTA) with regard to the setting time, radio-opacity, and microleakage. Setting times were evaluated using Vicat apparatus. Digital radiographs were taken to evaluate the aluminium equivalent radio-opacity using an aluminium step wedge. Extracted single-rooted teeth were used for leakage test using methylene blue dye. After canal shaping and obturation, the apical 3-mm root was resected, and a root-end cavity with a depth of 3 mm was prepared. The root-end cavities were filled with MTA, AMTA, and EPC for 15 specimens in each of three groups. After setting in humid conditions for 24 h, the specimens were tested for apical leakage. For evaluation of the biocompatibility of EPC, cell (human gingival fibroblast) viability was compared for MTA and Portland cement by MTT assay, and cell morphological changes were compared for MTA and AH Plus by fluorescence microscopy using DAPI and F-actin staining. The setting time, radio-opacity, and microleakage were compared using one-way ANOVA and Scheffe's post hoc comparison, and the cytotoxicity was compared using the nonparametric Kruskal-Wallis rank sum test. Statistical significance was set at 95%. EPC had a shorter setting time and less microleakage compared with MTA (p Portland cement, was found to be a useful material for root-end filling, with favourable radio-opacity, short setting time, low microleakage, and clinically acceptable low cytotoxicity. The novel root-end filling material would be a potentially useful material for a surgical endodontic procedure with favourable properties.

  17. Autoclave processing for composite material fabrication. 1: An analysis of resin flows and fiber compactions for thin laminate

    Science.gov (United States)

    Hou, T. H.

    1985-01-01

    High quality long fiber reinforced composites, such as those used in aerospace and industrial applications, are commonly processed in autoclaves. An adequate resin flow model for the entire system (laminate/bleeder/breather), which provides a description of the time-dependent laminate consolidation process, is useful in predicting the loss of resin, heat transfer characteristics, fiber volume fraction and part dimension, etc., under a specified set of processing conditions. This could be accomplished by properly analyzing the flow patterns and pressure profiles inside the laminate during processing. A newly formulated resin flow model for composite prepreg lamination process is reported. This model considers viscous resin flows in both directions perpendicular and parallel to the composite plane. In the horizontal direction, a squeezing flow between two nonporous parallel plates is analyzed, while in the vertical direction, a poiseuille type pressure flow through porous media is assumed. Proper force and mass balances have been made and solved for the whole system. The effects of fiber-fiber interactions during lamination are included as well. The unique features of this analysis are: (1) the pressure gradient inside the laminate is assumed to be generated from squeezing action between two adjacent approaching fiber layers, and (2) the behavior of fiber bundles is simulated by a Finitely Extendable Nonlinear Elastic (FENE) spring.

  18. Production and characterization of composite material based on ablative phenolic resin and carbon fibers

    International Nuclear Information System (INIS)

    Srebrenkoska, Vineta

    2002-01-01

    The optimisation of technology for production of moulding compound based on short carbon fibers and ablative phenolic resin is carried out. The characterisation of the starting raw materials is performed and moulding compounds With different fiber/matrix ratios and different fiber lengths are prepared. From the different samples, mouldings are produced by thermal compression. All physical, mechanical and thermal properties of the composites are tested. From the obtained results the optimal fiber/matrix ratio, for high temperature moulding compounds production are determined. Also, in order to meet the request for high thermal and mechanics properties of the composite, optimization is carded out on the moulding process itself. The optimization is fulfilled by a planned experiment. The full factorial experimental design is applied in which the following parameters are varied: fiber length, temperature and time of the press cycle. Regression equations for the influence of the parameters to the impact resistance, compression strength, flexural strength and the modulus of elasticity of the molding, are obtained. The obtained mechanical properties of the composite rate this material for potential application in the automotive, leisure, military and other industries.(Author)

  19. Material characterization of a polyester resin system for the pultrusion process

    DEFF Research Database (Denmark)

    Baran, Ismet; Akkerman, Remko; Hattel, Jesper Henri

    2014-01-01

    to develop a cure kinetics model which accurately predicts the cure rate evolutions and describes the curing behaviour of the resin over a wide range of different processing conditions. The viscosity of the resin is subsequently obtained from rheological experiments using a rheometer. Based on this, a resin....... The temperature- and curedependent elastic modulus of the resin system is determined using a dynamic mechanical analyzer (DMA) in tension mode. A cure hardening and thermal softening model is developed and a least squares non-linear regression analysis is performed. The variation in elastic modulus...... with temperature and phase transition is captured for a fully cured resin sample. © 2014 Elsevier Ltd. All rights reserved....

  20. Chiral transfer in coordination complexes: towards molecular materials.

    Science.gov (United States)

    Crassous, Jeanne

    2009-03-01

    In this critical review we present examples of coordination complexes with efficient chiral transfer determining stereochemistry at the metal centre and throughout the overall molecular assembly. The general features controlling the transmission of chirality are presented. The transfer of chirality are considered here with the special purpose of obtaining a molecular material displaying a particular property or function. Coordination complexes in fields as diverse as chiral luminescent materials, homochiral MOFs, chiral liquid crystals, enantioselective sensors, chiroptical switches, and magnetochiral compounds are presented (162 references).

  1. Effect Of Fly Ash Filler To Dielectric Properties Of The Insulator Material Of Silicone Rubber And Epoxy Resin

    Directory of Open Access Journals (Sweden)

    Ikhlas Kitta

    2015-08-01

    Full Text Available Currently many operated the coal fired power plant to meet the energy needs of the worlds electricity. But the coal fired power plant produces waste that can pollute the environment such as fly ash and bottom ash so requires management to not cause environmental problems because coal fly ash classified as a hazardous waste. Fly ash has a particle size that is very smooth and of some literature research done previously fly ash coal containing silica SiO2 alumina Al2O3 titanium dioxide TiO2 magnesium oxide MgO and zinc oxide ZnO are potentially as filler that are likely to be used as a mixture of silicone rubber and epoxy resin for electrical insulators. So this research theme was engineering insulation materials by utilizing waste coal fly ash. The purpose of this study was to obtain performance characteristics of waste coal fly ash as filler in silicon rubber and epoxy resin. To achieve these objectives the activities that have been done is examined the effects of the use of fly ash as filler in silicone rubber material and epoxy resin. Parameters measured were dielectric strength and relative permittivity. The result of this research is the dielectric strength of silicone rubber rose with increasing quantity of fly ash. Conversely in epoxy resin dielectric strength decreases with increasing quantity of fly ash. Furthermore the measurement results relative permittivity where the value of the relative permittivity of silicon rubber swell if it is filled with fly ash as well as epoxy resin which has a value of permittivity relative to the concentration of fly ash filler material is linear.

  2. Clinical application of removable partial dentures using thermoplastic resin. Part II: Material properties and clinical features of non-metal clasp dentures.

    Science.gov (United States)

    Fueki, Kenji; Ohkubo, Chikahiro; Yatabe, Masaru; Arakawa, Ichiro; Arita, Masahiro; Ino, Satoshi; Kanamori, Toshikazu; Kawai, Yasuhiko; Kawara, Misao; Komiyama, Osamu; Suzuki, Tetsuya; Nagata, Kazuhiro; Hosoki, Maki; Masumi, Shin-ichi; Yamauchi, Mutsuo; Aita, Hideki; Ono, Takahiro; Kondo, Hisatomo; Tamaki, Katsushi; Matsuka, Yoshizo; Tsukasaki, Hiroaki; Fujisawa, Masanori; Baba, Kazuyoshi; Koyano, Kiyoshi; Yatani, Hirofumi

    2014-04-01

    This position paper reviews physical and mechanical properties of thermoplastic resin used for non-metal clasp dentures, and describes feature of each thermoplastic resin in clinical application of non-metal clasp dentures and complications based on clinical experience of expert panels. Since products of thermoplastic resin have great variability in physical and mechanical properties, clinicians should utilize them with careful consideration of the specific properties of each product. In general, thermoplastic resin has lower color-stability and higher risk for fracture than polymethyl methacrylate. Additionally, the surface of thermoplastic resin becomes roughened more easily than polymethyl methacrylate. Studies related to material properties of thermoplastic resin, treatment efficacy and follow-up are insufficient to provide definitive conclusions at this time. Therefore, this position paper should be revised based on future studies and a clinical guideline should be provided. Copyright © 2014 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  3. Effect of chemical disinfectants and repair materials on the transverse strength of repaired heat-polymerized acrylic resin.

    Science.gov (United States)

    Ellakwa, Ayman E; El-Sheikh, Ali M

    2006-01-01

    The purpose of this study was to evaluate both the effects of immersion in different chemical disinfectant solutions and the type of repair material on the transverse strength of repaired heat-polymerized acrylic resin. A total of 110 rectangular specimens (65 x 10 x 3 mm) of heat-polymerized acrylic resin (Triplex) were fabricated. After polymerization, the specimens were polished, then stored in distilled water at 37 degrees C for 1 week. The specimens were divided into 11 groups (n = 10) coded A to K. Specimens of Group A remained intact (control). The specimens of Groups C to F and Groups H to K were immersed in the following chemical disinfectant solutions (1%, 2.5%, and 5.25% sodium hypochlorite and 2% glutaraldehyde, respectively) for 10 minutes. The specimens of all groups except those of Group A were sectioned in the middle to create 10 mm gaps and repaired with the same resin (Groups B to F) and autopolymerizing acrylic resin (Groups G to K). The specimens of Groups C to F and Groups H to K were again immersed in the disinfectant solutions in the same sequence. The transverse strength (N/mm(2)) was tested for failure in a universal testing machine, at a crosshead speed of 5 mm/min. Two-way analysis of variance (ANOVA) was performed to evaluate the effects of both the disinfectant solutions and repair materials on the transverse strength of repaired specimens. All data were statistically analyzed using one-way analysis of variance followed by Tukey's test at 95% confidence level. The repaired specimens treated with/without disinfectant solutions showed similar (p > 0.05) transverse strength values. No differences (p > 0.05) were detected among the repaired specimens either with heat-polymerized or autopolymerizing acrylic resins. The intact specimens showed transverse strength values (86.9 +/- 11.8) significantly higher (p disinfectants for the immersion period tested (10 min). The repair material, either heat-polymerized or autopolymerizing acrylic resin

  4. Effect of phase change material on the heat transfer rate of different building materials

    Science.gov (United States)

    Hasan, Mushfiq; Alam, Shahnur; Ahmed, Dewan Hasan

    2017-12-01

    Phase change material (PCM) is widely known as latent heat storage. A comprehensive study is carried out to investigate the effect of PCM on heat transfer rate of building materials. Paraffin is used as PCM along with different conventional building materials to investigate the heat transfer rate from the heated region to the cold region. PCM is placed along with the three different types of building materials like plaster which is well know building material in urban areas and wood and straw which are commonly used in rural areas for roofing as well as wall panel material and investigated the heat transfer rate. An experimental setup was constructed with number of rectangular shape aluminum detachable casing (as cavity) and placed side by side. Series of rectangular cavity filled with convent ional building materials and PCM and these were placed in between two chambers filled with water at different temperature. Building materials and PCM were placed in different cavities with different combinations and investigated the heat transfer rate. The results show that using the PCM along with other building materials can be used to maintain lower temperature at the inner wall and chamber of the cold region. Moreover, the placement or orientation of the building materials and PCM make significant contribution to heat transfer rate from the heated zone to the cold zone.

  5. Method development for the analysis of resinous materials with MALDI-FT-ICR-MS: novel internal standards and a new matrix material for negative ion mode.

    Science.gov (United States)

    Teearu, A; Vahur, S; Rodima, T; Herodes, K; Bonrath, W; Netscher, T; Tshepelevitsh, S; Trummal, A; Lõkov, M; Leito, I

    2017-09-01

    Matrix-assisted laser desorption/ionization (MALDI) is a mass spectrometry (MS) ionization technique suitable for a wide variety of sample types including highly complex ones such as natural resinous materials. Coupled with Fourier transform ion cyclotron resonance (FT-ICR) mass analyser, which provides mass spectra with high resolution and accuracy, the method gives a wealth of information about the composition of the sample. One of the key aspects in MALDI-MS is the right choice of matrix compound. We have previously demonstrated that 2,5-dihydroxybenzoic acid is suitable for the positive ion mode analysis of resinous samples. However, 2,5-dihydroxybenzoic acid was found to be unsuitable for the analysis of these samples in the negative ion mode. The second problem addressed was the limited choice of calibration standards offering a flexible selection of m/z values under m/z 1000. This study presents a modified MALDI-FT-ICR-MS method for the analysis of resinous materials, which incorporates a novel matrix compound, 2-aminoacridine for the negative ion mode analysis and extends the selection of internal standards with m/z negative (anions of four fluorine-rich sulpho-compounds) ion mode. The novel internal calibration compounds and matrix material were tested for the analysis of various natural resins and real-life varnish samples taken from cultural heritage objects. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  6. Effect of an adhesive resin luting agent on the dowel-head retention of three different core materials.

    Science.gov (United States)

    Aksoy, Gokhan; Cotert, H Serdar; Korkut, Levent

    2005-05-01

    A dowel-and-core restoration may fail due to failure at either the dowel-tooth or dowel head-core material interface. Long-term clinical success of a dowel-and-core restoration depends on retention of both the dowel to the tooth and the dowel head to the core material. Thus, strengthening of the dowel head-core interface is important. This study evaluated the retention between a prefabricated dowel and 3 different core materials with or without a dual-polymerized adhesive resin luting agent. Sixty prefabricated dowels (Gold Plated Anchorage Post) were divided into 3 groups (n=20) consisting of 1 of 3 core materials, amalgam (Standalloy F), light-polymerized resin composite (Clearfil Ray), or glass ionomer (Chelon-Silver). Each core group was divided into 2 subgroups (n=10), and a dual-polymerized adhesive resin luting agent (Panavia F) was applied to the dowel heads of 1 of these subgroups before application of the core material. The manufacturing procedure was standardized by using a plastic index (4.5-mm internal diameter and 5-mm height) and a custom-made dowel holder, which held the dowel head. Prepared specimens were stored in water at room temperature for 3 months and then loaded to fracture in a universal testing machine with a crosshead speed of 0.05 mm/min until failure. Bond strengths were recorded (MPa). Data were analyzed with 2-way analysis of variance (ANOVA) in a 2 x 3 factorial randomized design (alpha=.05). Afterward, core material differences were computed with 1-way ANOVA for both of the bonded and nonbonded groups. Post hoc multiple comparisons were made with the Dunnett C multiple range test. Dowel-head retention values (MPa) of the tested core materials (mean +/- SD) from the highest to the lowest were as follows: bonded amalgam core, 296.1 +/- 108; bonded composite core, 284.3 +/- 38.3; nonbonded composite core, 177.0 +/- 53.7; nonbonded amalgam core, 128.5 +/- 35.0; bonded glass-ionomer core (GIC), 128.0 +/- 24.5; nonbonded GIC, 61.8 +/- 13

  7. Robust Soft Textile Transfer Case for Contaminated Materials

    Science.gov (United States)

    2017-08-28

    significantly greater stresses are developed during drop impact and puncture tests due to the increased content and container weights. Working and...layer of the woven preform resists expansion when the interior bladder is inflated . The woven preform resembles an open cylinder, and when...chemically hazardous materials. After insertion, the transfer case is then sealed to protect the transport of the materials against drop impact , puncture

  8. Effect of the properties of natural resin binder in a high friction composite material

    Directory of Open Access Journals (Sweden)

    S. Stephen Bernard

    2014-01-01

    Full Text Available In this paper, a high-friction composite material based on the combination of binder, friction modifiers, fibers and fillers is investigated. In the binder, up to 20% of phenol are replaced by cardanol with various weight ratios of 100/0, 95/5, 90/10, 85/15, 80/20. Cardanol may react both through the phenolic group and the double bond of the side chain yielding addition, condensation and polymerisation reactions that allow the synthesis of tailor-made products and polymers of high value. In the present work, mechanical, thermal and wear characteristics of cardanol based phenolic resin with organic ingredients were manufactured and tested. An analysis of microstructure characteristics of composites was carried out using scanning electron microscope. The effect of environment on the composite was investigated in water, salty water and oil. The results showed that the addition of cardanol reduces the wear resistance and increases the compressibility which reduces the noise propensity.

  9. In-office bleaching efficacy on stain removal from CAD/CAM and direct resin composite materials.

    Science.gov (United States)

    Alharbi, Amal; Ardu, Stefano; Bortolotto, Tissiana; Krejci, Ivo

    2018-01-01

    To evaluate the efficacy of in-office bleaching on stain removal from stained resin composite and ceramic computer-assisted design/computer-assisted manufacturing (CAD/CAM) blocks and direct resin composites. Forty disk-shaped samples were fabricated from each of nine materials: six CAD/CAM (VITABLOCS Mark II, Paradigm MZ100, Exp Vita Hybrid Ceramic, VITA ENAMIC, Exp Kerr, and LAVA Ultimate) and three direct resin composites (Filtek Supreme, Venus Diamond, and Filtek Silorane). Samples were randomly divided into five groups (n = 8), each stained with a particular staining solution. Using a calibrated spectrophotometer and a black background, L*a*b* values were assessed before and after 120 days of staining. Samples were subjected to in-office bleaching using 40% hydrogen peroxide gel for one hour. At subsequent assessment, color change (ΔE) was calculated as the difference between L*a*b* values. Both ANOVA and the Duncan test were used to identify differences between groups (α = 0.05). Bleaching resulted in significant differences in ΔE values for all materials (P < .001). Bleaching efficacy was highly influenced by material composition and staining solution. Residual color values after bleaching for ceramic and hybrid ceramics ranged from -0.49 to 2.35, within the clinically acceptable maximum of 3.3. Values after bleaching for resin-based CAD/CAM ranged from -0.7 to 7.08 while direct resin composites values ranged from -1.47 to 25.13. Coffee left the greatest residual color on all materials. Based on material nature, 40% hydrogen peroxide bleaching can remove staining. The new resin-based CAD/CAM blocks showed promising results in terms of color stability. Bleaching using 40% hydrogen peroxide can be an effective method to remove stains from dental restorations. In this way, restoration replacement as a result of discoloration may no longer be necessary. © 2017 Wiley Periodicals, Inc.

  10. Evaluation of Flexural Strength of Thermocycled Interim Resin Materials Used in Prosthetic Rehabilitation- An In-vitro Study

    Science.gov (United States)

    Kadiyala, Krishna Kishore; Anne, Gopinadh; Anche, Sampath Chowdary; Chiramana, Sandeep; Muvva, Suresh Babu; Zakkula, Srujana; Jyothula, Ravi Rakesh Dev

    2016-01-01

    Introduction Provisional restoration is an analytical component of fixed prosthodontics serving as a ground plan for the design of fixed dental prosthesis. Flexural strength is critical in case of long standing fixed dental prosthesis, to appreciate success of full mouth rehabilitation cases and temporomandibular joint dysfunction therapies. Aim The present study was to evaluate the flexural strength of different provisional restorative resins used for prosthetic rehabilitation. Materials and Methods Forty identical samples (n=10 for each material) measuring 25mm×2mm×2mm according to ADA/ANSI specification no. 27 were fabricated using autopolymerizing Poly Methyl Methacrylate (PMMA) (Group A); heat activated PMMA (Group B); autopolymerizing Bis-GMA composite resin (Group C) and light activated Urethane Dimethacrylate Resin (UDMA) (Group D). For 14 days all these samples were stored in artificial saliva. Ten samples from each material were subjected to thermal cycling for 2500 cycles (5°C to 55°C). Later, a standard three point bending test was conducted on all the specimens with a universal testing machine at a crosshead speed of 0.75mm/min. Statistical analysis used included Kruskal-Wallis and Mann-Whitney U test. Results The mean flexural strength of specimens confirmed higher flexural strength for Group C (102.98 Mpa) followed by Group B (91.86 Mpa), Group A (79.13 Mpa) and Group D (60.01 Mpa). There were significant differences between any two materials tested (p treatment. PMID:27790588

  11. Cell death effects of resin-based dental material compounds and mercurials in human gingival fibroblasts

    Energy Technology Data Exchange (ETDEWEB)

    Reichl, Franz-Xaver [Walther-Straub-Institute of Pharmacology and Toxicology, Munich (Germany); Ludwig-Maximilians-University, Department of Operative Dentistry and Periodontology, Munich (Germany); Esters, Magali; Simon, Sabine; Seiss, Mario [Walther-Straub-Institute of Pharmacology and Toxicology, Munich (Germany); Kehe, Kai [Bundeswehr Institute of Pharmacology and Toxicology, Munich (Germany); Kleinsasser, Norbert [University of Regensburg, Head and Neck Surgery, Department of Otolaryngology, Regensburg (Germany); Folwaczny, Matthias; Glas, Juergen; Hickel, Reinhard [Ludwig-Maximilians-University, Department of Operative Dentistry and Periodontology, Munich (Germany)

    2006-06-15

    In order to test the hypothesis that released dental restorative materials can reach toxic levels in human oral tissues, the cytotoxicities of the resin-based dental (co)monomers hydroxyethylmethacrylate (HEMA), triethyleneglycoldimethacrylate (TEGDMA), urethanedimethacrylate (UDMA), and bisglycidylmethacrylate (BisGMA) compared with methyl mercury chloride (MeHgCl) and the amalgam component mercuric chloride (HgCl{sub 2}) were investigated on human gingival fibroblasts (HGF) using two different test systems: (1) the modified XTT-test and (2) the modified H 33342 staining assay. The HGF were exposed to various concentrations of the test-substances in all test systems for 24 h. All tested (co)monomers and mercury compounds significantly (P<0.05) decreased the formazan formation in the XTT-test. EC{sub 50} values in the XTT assay were obtained as half-maximum-effect concentrations from fitted curves. Following EC{sub 50} values were found (mean [mmol/l]; s.e.m. in parentheses; n=12; * significantly different to HEMA): HEMA 11.530 (0.600); TEGDMA* 3.460 (0.200); UDMA* 0.106 (0.005); BisGMA* 0.087 (0.001); HgCl{sub 2}* 0.013 (0.001); MeHgCl* 0.005 (0.001). Following relative toxicities were found: HEMA 1; TEGDMA 3; UDMA 109; BisGMA 133; HgCl{sub 2} 887; MeHgCl 2306. A significant (P<0.05) increase of the toxicity of (co)monomers and mercurials was found in the XTT-test in the following order: HEMA < TEGDMA < UDMA < BisGMA < HgCl{sub 2} < MeHgCl. TEGDMA and MeHgCl induced mainly apoptotic cell death. HEMA, UDMA, BisGMA, and HgCl{sub 2} induced mainly necrotic cell death. The results of this study indicate that resin composite components have a lower toxicity than mercury from amalgam in HGF. HEMA, BisGMA, UDMA, and HgCl{sub 2} induced mainly necrosis, but it is rather unlikely that eluted substances (solely) can reach concentrations, which might induce necrotic cell death in the human physiological situation, indicating that other (additional) factors may be involved in

  12. Paramagnetic epoxy resin

    Directory of Open Access Journals (Sweden)

    E. C. Vazquez Barreiro

    2017-01-01

    Full Text Available This work illustrates that macrocycles can be used as crosslinking agents for curing epoxy resins, provided that they have appropriate organic functionalities. As macrocycles can complex metal ions in their structure, this curing reaction allows for the introduction of that metal ion into the resin network. As a result, some characteristic physical properties of the metallomacrocycle could be transferred to the new material. The bisphenol A diglycidyl ether (BADGE, n = 0 and hemin (a protoporphyrin IX containing the Fe(III ion, and an additional chloride ligand have been chosen. The new material has been characterized by differential scanning calorimetry (DSC, thermogravimetric analysis (TGA, Fourier Transform Infrared (FT-IR, Nuclear Magnetic Resonance (NMR, Transmission Electron Microscopy (TEM, and magnetic susceptibility measurements. Fe(III remains in the high-spin state during the curing process and, consequently, the final material exhibits the magnetic characteristics of hemin. The loss of the chlorine atom ligand during the cure of the resin allows that Fe(III can act as Lewis acid, catalyzing the crosslinking reactions. At high BADGE n = 0/hemin ratios, the formation of ether and ester bonds occurs simultaneously during the process.

  13. A new approach to influence contact angle and surface free energy of resin-based dental restorative materials.

    Science.gov (United States)

    Rüttermann, Stefan; Trellenkamp, Taina; Bergmann, Nora; Raab, Wolfgang H-M; Ritter, Helmut; Janda, Ralf

    2011-03-01

    The purpose of the present study was to identify novel delivery systems and active agents which increase the water contact angle and reduce the surface free energy when added to resin-based dental restorative materials. Two delivery systems based on zeolite or novel polymeric hollow beads (Poly-Pore), loaded with two low surface tension active agents (hydroxy functional polydimethylsiloxane and polydimethylsiloxane) or a polymerizable active agent (silicone polyether acrylate) were used to modify commonly formulated experimental dental resin composites. The non-modified resin was used as a standard (ST). Flexural strength, flexural modulus, water sorption, solubility, polymerization shrinkage, surface roughness Ra, contact angle θ, total surface free energy γS, and the apolar γSLW, polar γSAB, Lewis acid γS+ and base γS- components, and the active agents surface tensions γL were determined (Ptension active agents were found not to influence the physical properties but to significantly increase the water contact angle and thus reduce surface free energy of dental resin composites. Copyright © 2010 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  14. Contact angle and surface free energy of experimental resin-based dental restorative materials after chewing simulation.

    Science.gov (United States)

    Rüttermann, Stefan; Beikler, Thomas; Janda, Ralf

    2014-06-01

    To investigate contact angle and surface free energy of experimental dental resin composites containing novel delivery systems of polymeric hollow beads and low-surface tension agents after chewing simulation test. A delivery system of novel polymeric hollow beads differently loaded with two low-surface tension agents was used in different amounts to modify commonly formulated experimental dental resin composites. The non-modified resin was used as standard. Surface roughness Ra, contact angle Θ, total surface free energy γS, its apolar γS(LW), polar γS(AB), Lewis acid γS(+) and base γS(-) terms were determined and the results prior to and after chewing simulation test were compared. Significance was phollow beads highly loaded with low-surface tension agents were found to significantly increase contact angle and thus to reduce surface free energy of experimental dental resin composites prior to and after chewing simulation test. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  15. Method for removing contaminants from plastic resin

    Science.gov (United States)

    Bohnert, George W [Harrisonville, MO; Hand, Thomas E [Lee's Summit, MO; DeLaurentiis, Gary M [Jamestown, CA

    2008-12-09

    A resin recycling method that produces essentially contaminant-free synthetic resin material in an environmentally safe and economical manner. The method includes receiving the resin in container form. The containers are then ground into resin particles. The particles are exposed to a solvent, the solvent contacting the resin particles and substantially removing contaminants on the resin particles. After separating the particles and the resin, a solvent removing agent is used to remove any residual solvent remaining on the resin particles after separation.

  16. Evaluation of adhesive bonding of lithium disilicate ceramic material with duel cured resin luting agents.

    Science.gov (United States)

    Lambade, Dipti Pravin; Gundawar, Sham M; Radke, Usha M

    2015-02-01

    The purpose of this vitro study was to comparatively evaluate the adhesive bonding of dual cured resin luting agents with lithium disilicate ceramic material. Porcelain laminate veneers were prepared with lithium disilicate ceramic material i.e. IPS Empress II( E-Max Press). These laminates were bonded with RelyX ARC, Panavia F 2.0, Variolink II, Duolink and Nexus NX3.The porcelain laminates were etched with 9.6% hydrofluoric acid (Pulpdent Corporation) for one minute, washed for 15 sec with three way syringe and dried for 15 sec with air syringe. The silane (Ultradent) was applied with the help of applicator tip in a single coat and kept undisturbed for one minute. The prepared surfaces of the premolars were treated with 37% phosphoric acid (Prime dent) for 15 sec, thoroughly rinsed and dried as per manufactures instructions. The shear bond test was carried out on all samples with the Universal testing machine (Instron U.S.A.) The scanning electron microscopic study was performed at the fractured interface of representative samples from each group of luting agents. In this study, the highest value of shear bond strength was obtained for NEXUS NX3 and the lowest for VARIOLINK II. The difference in bond strength can be interpreted as the difference in fracture resistance of luting agents, to which shearing load was applied during the shear bond strength test. It is inferred from this study that the composition of the luting agent determines the adhesive characteristics in addition to surface treatment and bonding surface area.

  17. Mechanistic understanding of fouling of protein A chromatography resin.

    Science.gov (United States)

    Pathak, Mili; Rathore, Anurag S

    2016-08-12

    This paper aims to provide a thorough understanding of how fouling of Protein A resin takes place. Binding and mass transport properties of widely used agarose-based Protein A resin, MabSelect SuRe™, have been examined to understand the mechanism of resin fouling. There could be various factors that impact resin fouling. These include product/impurity build-up due to components in the feed material and ligand degradation due to the use of harsh buffers. To unravel their contributions, cycling studies were performed with and without product loading. The results presented in this paper provide a lucid understanding of the causative factors that limit Protein A chromatographic resin lifetime. The capacity fall for protein A resin at the end of 100th cycle due to use of feed material was found to be five times greater than that without using feed material. Compared to the fresh resin, the cycled resin samples shows 24% reduction in particle porosity and 51% reduction in pore mass transfer coefficient. Transmission electron microscopy (TEM) was used to qualitatively monitor accumulation of foulants on the cycled resin. Fouled resin sample contained a dense residue in the interior and exterior of resin particle both as a film at the bead surface and as granules. The surface activation energy increased five times in the case of fouled resin sample. The major event in fouling was identified as the non-specific adsorption of the feed material components on resin, signaling that pore diffusion is the rate limiting step. It is anticipated that these findings will assist in development of a more robust and economical downstream manufacturing process for monoclonal antibody purification. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Novel Dental Restorative Materials having Low Polymerization Shrinkage Stress via Stress Relaxation by Addition-Fragmentation Chain Transfer

    Science.gov (United States)

    Park, Hee Young; Kloxin, Christopher J.; Abuelyaman, Ahmed S.; Oxman, Joe D.; Bowman, Christopher N.

    2012-01-01

    Objectives To produce a reduced stress dental restorative material while simultaneously maintaining excellent mechanical properties, we have incorporated an allyl sulfide functional group into norbornene-methacrylate comonomer resins. We hypothesize that the addition-fragmentation chain transfer (AFCT) enabled by the presence of the allyl sulfide relieves stress in these methacrylate-based systems while retaining excellent mechanical properties owing to the high glass transition temperature of norbornene-containing resins. Methods An allyl sulfide-containing dinorbornene was stoichiometrically formulated with a ring-containing allyl sulfide-possessing methacrylate. To evaluate the stress relaxation effect as a function of the allyl sulfide concentration, a propyl sulfide-based dinorbornene, not capable of addition-fragmentation, was also formulated with the methacrylate monomer. Shrinkage stress, the glass transition temperature and the elastic modulus were all measured. The composite flexural strength and modulus were also measured. ANOVA (CI 95%) was conducted to determine differences between the means. Results Increasing the allyl sulfide content in the resin dramatically reduces the final stress in the norbornene-methacrylate systems. Both norbornene-methacrylate resins demonstrated almost zero stress (more than 96% stress reduction) compared with the conventional BisGMA/TEGDMA 70/30 wt% control. Mechanical properties of the allyl sulfide-based dental composites were improved to the point of being statistically indistinguishable from the control BisGMA-TEGDMA by changing the molar ratio between the methacrylate and norbornene functionalities. Significance The allyl sulfide-containing norbornene-methacrylate networks possessed super-ambient Tg, and demonstrated significantly lower shrinkage stress when compared with the control (BisGMA/TEGDMA 70 to 30 wt%). Although additional development remains, these low stress materials exhibit excellent mechanical

  19. Physical Properties of a New Sonically Placed Composite Resin Restorative Material

    Science.gov (United States)

    2013-06-06

    microleakage with resulting pulpal sensitivity, staining , and recurrent caries.10 Additionally, incomplete curing of composite resins is associated...minimal stress.10 However, increased demand has led to greater use on posterior teeth , where considerable mechanical challenges occur under function...was placed on a plastic-strip-covered glass slide on a standard white background. The composite resin was injected into the mold and a plastic strip

  20. Substitute materials of furfuryl alcohol in furan resin used for foundry and their technical properties

    Directory of Open Access Journals (Sweden)

    Li Yingmin

    2009-11-01

    Full Text Available Based on a special synthesis process of furan resin, the furfuryl alcohol (FA, the main component of typical no-bake furan resins is substituted by ethanol and xylitol mother liquor which is relatively low price and chemically active. Through orthogonal test, the optimal amount of xylitol liquor, ethanol and modifi er has been determined. Finally, the test results on technical properties show that the performance can meet the production requirement well, which indicate a success in this substituting attempt.

  1. Thermal expansion and swelling of cured epoxy resin used in graphite/epoxy composite materials

    Science.gov (United States)

    Adamson, M. J.

    1980-01-01

    The paper presents results of experiments in which the thermal expansion and swelling behavior of an epoxy resin system and two graphite/epoxy composite systems exposed to water were measured. It was found that the cured epoxy resin swells by an amount slightly less than the volume of the absorbed water and that the swelling efficiency of the water varies with the moisture content of the polymer. Additionally, the thermal expansion of cured epoxy resin that is saturated with water is observed to be more than twice that of dry resin. Results also indicate that cured resin that is saturated with 7.1% water at 95 C will rapidly increase in moisture content to 8.5% when placed in 1 C water. The mechanism for this phenomenon, termed reverse thermal effect, is described in terms of a slightly modified free-volume theory in conjunction with the theory of polar molecule interaction. Nearly identical behavior was observed in two graphite/epoxy composite systems, thus establishing that this behavior may be common to all cured epoxy resins.

  2. Microleakage of conventional, resin-modified, and nano-ionomer glass ionomer cement as primary teeth filling material

    Directory of Open Access Journals (Sweden)

    Dita Madyarani

    2014-12-01

    Full Text Available Background: Glass ionomer cements are one of many dental materials that widely used in pediatric dentistry due to their advantage of fluoride release and chemical bond to tooth structure. Adherence of the filling material to the cavity walls is one of the most important characteristic that need to be examined its effect on microleakage. Purpose: This study was conducted to examine the microleakage of nano-ionomer glass ionomer cement compared with the conventional and resin-modified glass ionomer cements. Methods: Standard class V cavities sized 3 mm x 2 mm x 2 mm were made on a total of 21 extracted maxillary primary canine teeth and restored with the conventional, resin-modified, dan nano-ionomer glass ionomer cements. All the teeth were immersed in a 2% methylene blue dye for 4 hours. The depth of dye penetration was assessed using digital microscope after sectioning the teeth labio-palatally. The results were statistically analyzed using Kruskal-Wallis test. Results: All type of glass ionomer material showed microleakage. Conventional glass ionomer cement demonstrated the least microleakage with mean score 1.29. the resin-modified glass ionomer cements (mean score 1.57 and nano-ionomer glass ionomer cement (mean score 2.57. Conclusion: The conventional glassionomer, resin modified glassionomer, and nano-ionomer glassionomer showed micro leakage as filling material in primary teeth cavity. The micro leakage among three types was not significant difference. All three material were comparable in performance and can be used for filling material but still needs a coating material to fill the microleakage.Latar belakang: Semen ionomer kaca adalah salah satu dari banyak bahan gigi yang banyak digunakan dalam praktek kedokteran gigi anak karena bahan tersebut merilis fluoride dan berikatan kimia dengan struktur gigi. Perlekatan bahan tumpatan pada dinding kavitas adalah salah satu karakteristik paling penting yang perlu diteliti efeknya terhadap

  3. Bond strength of novel CAD/CAM restorative materials to self-adhesive resin cement: the effect of surface treatments.

    Science.gov (United States)

    Elsaka, Shaymaa E

    2014-12-01

    To evaluate the effect of different surface treatments on the microtensile bond strength (μTBS) of novel CAD/CAM restorative materials to self-adhesive resin cement. Two types of CAD/CAM restorative materials (Vita Enamic [VE] and Lava Ultimate [LU]) were used. The specimens were divided into five groups in each test according to the surface treatment performed; Gr 1 (control; no treatment), Gr 2 (sandblasted [SB]), Gr 3 (SB+silane [S]), Gr 4 (hydrofluoric acid [HF]), and Gr 5 (HF+S). A dual-curing self-adhesive resin cement (Bifix SE [BF]) was applied to each group for testing the adhesion after 24 h of storage in distilled water or after 30 days using the μTBS test. Following fracture testing, specimens were examined with a stereomicroscope and SEM. Surface roughness and morphology of the CAD/CAM restorative materials were characterized after treatment. Data were analyzed using ANOVA and Tukey's test. The surface treatment, type of CAD/CAM restorative material, and water storage periods showed a significant effect on the μTBS (p0.05). On the other hand, for the VE/BF system, surface treatment with HF+S showed higher bond strength values compared with SB and HF surface treatments (pmaterials was modified after treatments. The effect of surface treatments on the bond strength of novel CAD/CAM restorative materials to resin cement is material dependent. The VE/BF CAD/CAM material provided higher bond strength values compared with the LU/BF CAD/CAM material.

  4. Advanced resin systems and 3D textile preforms for low cost composite structures

    Science.gov (United States)

    Shukla, J. G.; Bayha, T. D.

    1993-01-01

    Advanced resin systems and 3D textile preforms are being evaluated at Lockheed Aeronautical Systems Company (LASC) under NASA's Advanced Composites Technology (ACT) Program. This work is aimed towards the development of low-cost, damage-tolerant composite fuselage structures. Resin systems for resin transfer molding and powder epoxy towpreg materials are being evaluated for processability, performance and cost. Three developmental epoxy resin systems for resin transfer molding (RTM) and three resin systems for powder towpregging are being investigated. Various 3D textile preform architectures using advanced weaving and braiding processes are also being evaluated. Trials are being conducted with powdered towpreg, in 2D weaving and 3D braiding processes for their textile processability and their potential for fabrication in 'net shape' fuselage structures. The progress in advanced resin screening and textile preform development is reviewed here.

  5. The impact of three strains of oral bacteria on the surface and mechanical properties of a dental resin material.

    Science.gov (United States)

    Gregson, Karen S; Shih, Han; Gregory, Richard L

    2012-08-01

    The purpose of this study was to determine if three strains of bacteria could impact the mechanical or surface properties of a dental resin material. Resin material specimens were incubated at 37°C in sterile saline, tryptic soy broth supplemented with sucrose (TSBS), or TSBS inoculated with Streptococcus mutans, Streptococcus gordonii, or Streptococcus sanguis. The specimens were subjected to Fourier transform infrared spectroscopy before and after incubation. The flexural strength test was performed once a week for 6 weeks. Microhardness and scanning electron microscopy (SEM) was performed on specimens at 1 and 6 weeks. Differences in the area under the carbonyl peak were statistically significant for the specimens incubated in the media inoculated with either S. mutans or S. gordonii. To determine why S. sanguis did not produce changes as the other bacteria did, triethylene glycol dimethacrylate, methacrylic acid, and triethylene glycol were added to bacterial cultures at increasing concentrations. Both methacrylic acid and triethylene glycol reduced the number of colony-forming units of S. sanguis. Specimens incubated in TSBS, saline or in culture with S. sanguis demonstrated a decrease in peak stress in week 1 of the flexure strength test. SEM demonstrated that surface topology changed for those specimens incubated in culture with S. mutans or S. gordonii. The changes in surface topology demonstrated here could contribute to the secondary caries and changes in esthetic properties seen clinically with the use of resin materials in dental restorations.

  6. Current status of visible light activation units and the curing of light-activated resin-based composite materials.

    Science.gov (United States)

    Santini, Ario

    2010-05-01

    Light activation units are standard items of equipment in dental practice. It is essential to understand the many factors which affect the polymerization of light-activated resin composite materials and the choice of a light curing unit. In this respect, the development of high-intensity halogen and light-emitting diode (LED) light curing units (LCUs), many with multiple curing modes, has revolutionized light curing techniques. This article reviews visible light activation unit design and development. Factors influencing the effective use of LCUs and polymerization of resin-based composite materials are discussed, as are the steps which should be taken to maintain the efficiency of units in clinical use. Many LCUs produce lower output intensities than stated by the manufacturer. Newer high power LEDs may present as much of a heat problem as high power quartz tungsten halogen lamps (QTHs).The manufacturer's data should be followed to ensure that the emission spectra of the unit is compatible with the photo-initiator in the resin-based composite material.

  7. Resin-modified glass-ionomer cements versus resin-based materials as fissure sealants: a meta-analysis of clinical trials.

    Science.gov (United States)

    Yengopal, V; Mickenautsch, S

    2010-02-01

    To appraise quantitatively current evidence regarding the caries-preventing effect of resin-modified glass-ionomer cement (RM-GIC) fissure sealants in comparison to that of resin-based fissure sealants. Systematic review with meta-analysis. 8 Anglophone databases and 2 Lusophone databases were searched until 15 April 2009, using a pre-determined search strategy. Clinical trials were considered for inclusion if their titles/abstracts were relevant to the topic, published in English, Portuguese or Spanish and had a two-arm longitudinal study design. The outcome measure of the caries-preventive effect was caries absence on sealed teeth. Two reviewers independently extracted data from the accepted articles in order to complete a 2x2 table for meta-analysis. The unit of interest was the tooth, and the number of caries-free teeth (n) at the end of each time interval (6, 12 and 24 months) was compared against the total number of evaluated teeth (N). Datasets were assessed for their clinical and methodological heterogeneity, following Cochrane guidelines, and only homogeneous datasets were combined for meta-analysis, using a random effects model (RevMan 4.2). Differences in the caries-preventive effect were computed on the basis of the combined Relative Risk (RR) with 95% confidence interval (CI). Of the 212 articles identified, only 6 trials were included. From these, 19 separate datasets were extracted. For the pooled data, equivalent caries-preventive effects were observed at 6 months (RR= 0.98, 95% CI 0.95- 1.00; p = 0.08); 12 months (RR=1.00, 95% CI 0.96-1.04, p = 0.99) and 24 months (RR=1.01, 95% CI 0.84-1.21, p = 0.91). The 36-month data (not pooled) favoured resin-based sealants (RR 0.93, 95% CI 0.88-0.97, p = 0.002). This meta-analysis found no conclusive evidence that either material was superior to the other in preventing dental caries.

  8. In vitro toothbrushing abrasion of dental resin composites: packable, microhybrid, nanohybrid and microfilled materials

    Directory of Open Access Journals (Sweden)

    Rafael Ratto de Moraes

    2008-06-01

    Full Text Available This study evaluated weight loss and surface roughening after toothbrushing of different resin composites: one packable (Solitaire 2, Heraeus Kulzer, one microhybrid (Charisma, Heraeus Kulzer, one nanohybrid (Simile, Pentron and one microfilled (Durafill VS, Heraeus Kulzer. Cylindrical specimens (n = 20 were prepared. Half of the samples were submitted to 60,000 strokes, at 4 Hz, with a dentifrice-water slurry. Control samples (n = 10 remained stored at 37°C. Pre- and post-abrasion parameters for weight (mg and surface roughness (Ra, µm were determined on an analytical balance and a surface profilometer. Data were separately submitted to Repeated Measures ANOVA and Tukey's test (a = 0.05. Percentages of weight loss were analyzed by ANOVA and Tukey's test (a = 0.05. The relationship between both evaluations was assessed by Pearson's test (a = 0.05. The means (% for weight loss (standard deviation were 0.65(0.2, 0.93(0.2, 1.25(0.6 and 1.25(0.4 for Simile, Durafill, Charisma and Solitaire, respectively. Baseline roughness means ranged from 0.065(0.01, 0.071(0.01, 0.066(0.02 and 0.074(0.01 for Simile, Durafill, Charisma and Solitaire, respectively, to 0.105(0.04, 0.117(0.03, 0.161(0.03 and 0.214(0.07 after testing. The composites with larger fillers presented higher weight loss and roughening than the finer materials (p < 0.05. For both evaluations, control specimens showed no significant alteration. No significant relationship between loss of weight and roughness alteration was detected (r = 0.322, p = 0.429.

  9. Effect of LED-LCU light irradiance distribution on mechanical properties of resin based materials

    Energy Technology Data Exchange (ETDEWEB)

    Magalhães Filho, T.R.; Weig, K.M. [Faculdade de Odontologia, Universidade Federal Fluminense, Rua São Paulo 28, CEP 24020-150 Niterói (Brazil); Engenharia Metalúrgica e de Materiais (COPPE), Universidade Federal do Rio de Janeiro, CP 68505, CEP: 21941-972 Rio de Janeiro (Brazil); Costa, M.F. [Engenharia Metalúrgica e de Materiais (COPPE), Universidade Federal do Rio de Janeiro, CP 68505, CEP: 21941-972 Rio de Janeiro (Brazil); Werneck, M.M. [Engenharia Elétrica (COPPE), Universidade Federal do Rio de Janeiro, CP 68504, CEP: 21941-972 Rio de Janeiro (Brazil); Barthem, R.B. [Instituto de Física, Universidade Federal do Rio de Janeiro, CP 68528, CEP: 21941-972 Rio de Janeiro (Brazil); Costa Neto, C.A., E-mail: celio@metalmat.ufrj.br [Engenharia Metalúrgica e de Materiais (COPPE), Universidade Federal do Rio de Janeiro, CP 68505, CEP: 21941-972 Rio de Janeiro (Brazil)

    2016-06-01

    The objective of this study is to analyze the light power distribution along the tip end of the light guide of three LED-LCUs (Light Curing Units) and to evaluate its effect on the mechanical properties of a polymer based dental composite. Firstly, the light power distribution over the whole area of LED-LCU light guide surface was analyzed by three methods: visual projection observation, spectral measurement and optical spectral analysis (OSA). The light power distribution and the total irradiance were different for the three LEDs used, but the wavelength was within the camphorquinone absorption spectrum. The use of a blank sheet was quite on hand to make a qualitative analysis of a beam, and it is costless. Secondly, specimens of a hybrid composite with approximately 8 mm diameter and 2 mm thickness were produced and polymerized by 20 s exposition time to each LED-LCU. Thirdly, the elastic modulus (E) and hardness (HV) were measured throughout the irradiated area by instrumented micro-indentation test (IIT), allowing to correlate localized power and mechanical properties. Both E and HV showed to be very sensitive to local power and wavelength dependent, but they followed the beam power profile. It was also shown that the mechanical properties could be directly correlated to the curing process. Very steep differences in mechanical properties over very short distances may impair the material performance, since residual stresses can easily be built over it. - Highlights: • A resin based composite (RBC) was polymerized by three different Light Emitting Diodes. • Each LED had its beam profile visually, wavelength and power analyzed. • The effective polymerization power (EPP) varied from 28% to 52% of the total beam power. • Wavelength seems to be as relevant as power in the light curing process. • Mechanical properties depend on the simultaneous effect of wavelength and power.

  10. Influence of different surface treatments on bond strength of novel CAD/CAM restorative materials to resin cement.

    Science.gov (United States)

    Kömürcüoğlu, Meltem Bektaş; Sağırkaya, Elçin; Tulga, Ayça

    2017-12-01

    To evaluate the effects of different surface treatments on the bond strength of novel CAD/CAM restorative materials to resin cement by four point bending test. The CAD/CAM materials under investigation were e.max CAD, Mark II, Lava Ultimate, and Enamic. A total of 400 bar specimens (4×1.2×12 mm) (n=10) milled from the CAD/CAM blocks underwent various pretreatments (no pretreatment (C), hydrofluoric acid (A), hydrofluoric acid + universal adhesive (Scotchbond) (AS), sandblasting (Sb), and sandblasting + universal adhesive (SbS)). The bars were luted end-to-end on the prepared surfaces with a dual curing adhesive resin cement (Variolink N, Ivoclar Vivadent) on the custom-made stainless steel mold. Ten test specimens for each treatment and material combination were performed with four point bending test method. Data were analyzed using ANOVA and Tukey's test. The surface treatment and type of CAD/CAM restorative material showed a significant effect on the four point bending strength (FPBS) ( P CAD/CAM restorative materials was modified after treatments. The surface treatment of sandblasting or HF acid etching in combination with a universal adhesive containing MDP can be suggested for the adhesive cementation of the novel CAD/CAM restorative materials.

  11. Carbon transfer tests of FBR structural materials in flowing sodium

    International Nuclear Information System (INIS)

    Ohta, Y.; Atsumo, H.; Maruyama, A.; Nakasuji, T.

    1980-01-01

    Since the secondary cooling system of Liquid-Metal Fast Breeder Prototype Reactor Monju consists of a bimetallic loop of austenitic stainless steel and ferritic low alloy steel, carburization occurs in stainless steel and decarburization in low alloy steel mainly due to the difference in carbon activity between the two materials. This phenomenon is thought of suffer reduction in their mechanical properties. In Japan also, since it is necessary to clarify these phenomena quantitatively and feed back the result to the design standard, quantitative evaluation of the amounts of carburization and decarburization as well as studies on the changes in strength of the structural materials caused by these carbon transfer have been underway. Since these studies have not yet reached the final stage, this paper provides mainly an interim report on carbon transfer behavior test and introduction of partial data

  12. Historic transfer of forest reproductive material in the Nordic region

    DEFF Research Database (Denmark)

    Myking, Tor; Rusanen, Mari; Steffenrem, Arne

    2016-01-01

    and gene pools of key forest tree species. We find that large imports of non-native FRM occurred from the 19th century onwards, partly due to prior deforestations directly associated with charcoal production for mining, extraction of timber and production of tar and pitch which have historically been......Large-scale transfer of reproductive material is a common phenomenon in forestry and is not only limited to recent history. Here we review the historical transfer of forest reproductive material (FRM) in Fennoscandia, the directions, their drivers, and the reported consequences for adaptation...... important export commodities for Sweden, Norway, and Finland. In Denmark, conversion to agricultural land and the use of forests for livestock feeding was similarly important. During the subsequent reforestation efforts in Denmark, the introduction and use of non-autochthonous FRM of beech, oak and Scots...

  13. Characteristics of low polymerization shrinkage flowable resin composites in newly-developed cavity base materials for bulk filling technique.

    Science.gov (United States)

    Nitta, Keiko; Nomoto, Rie; Tsubota, Yuji; Tsuchikawa, Masuji; Hayakawa, Tohru

    2017-11-29

    The purpose of this study was to evaluate polymerization shrinkage and other physical properties of newly-developed cavity base materials for bulk filling technique, with the brand name BULK BASE (BBS). Polymerization shrinkage was measured according to ISO/FDIS 17304. BBS showed the significantly lowest polymerization shrinkage and significantly higher depth of cure than conventional flowable resin composites (p<0.05). The Knoop hardness, flexural strength and elastic modulus of that were significantly lower than conventional flowable resin composites (p<0.05). BBS had the significantly greatest filler content (p<0.05). SEM images of the surface showed failure of fillers. The lowest polymerization shrinkage was due to the incorporation of a new type of low shrinkage monomer, which has urethane moieties. There were no clear correlations between inorganic filler contents and polymerization shrinkage, flexural strength and elastic modulus. In conclusion, the low polymerization shrinkage of BBS will be useful for cavity treatment in dental clinics.

  14. Vibration monitoring for aircraft wing model using fiber Bragg grating array packaged by vacuum-assisted resin transfer molding

    Science.gov (United States)

    Zhang, Wen; Liu, Xiaolong; He, Wei; Dong, Mingli; Zhu, Lianqing

    2017-09-01

    For the improvement of monitoring accuracy, a vibration monitoring for aircraft wing model using a fiber Bragg grating (FBG) array packaged by vacuum-assisted resin transfer molding (VARTM) is proposed. The working principle of the vibration monitoring using FBG array has been explained, which can theoretically support the idea of this paper. VARTM has been explained in detail, which is suitable for not only the single FBG sensor but also the FBG array within a relatively large area. The calibration experiment has been performed using the FBG sensor packaged by VARTM. The strain sensitivity of the VARTM package is 1.35 pm/μɛ and the linearity is 0.9999. The vibration monitoring experiment has been carried out using FBG array packaged by VARTM. The measured rate of strain changes across the aluminum test board used to simulate the aircraft wing is 0.69 μɛ/mm and the linearity is 0.9931. The damping ratio is 0.16, which could be further used for system performance evaluation. Experimental results demonstrate that the vibration monitoring using FBG sensors packaged by VARTM can be efficiently used for the structural health monitoring. Given the validation and great performance, this method is quite promising for in-flight monitoring and holds great reference value in other similar engineering structures.

  15. Underground processing method for radiation-contaminated material and transferring method for buffer molding material

    International Nuclear Information System (INIS)

    Akasaka, Hidenari; Shimura, Satoshi; Asano, Eiichi; Yamagata, Junji; Ninomiya, Nobuo; Kawakami, Susumu.

    1995-01-01

    A bottomed molding material (buffer molding material) is formed into a bottomed cylindrical shape by solidifying, under pressure, powders such as of bentonite into a highly dense state by a cold isotropic pressing or the like, having a hole for accepting and containing a vessel for radiation-contaminated materials. The bottomed cylindrical molding material is loaded on a transferring vessel, and transferred to a position near the site for underground disposal. The bottomed cylindrical molding material having a upwarded containing hole is buried in the cave for disposal. The container for radiation-contaminated material is loaded and contained in the containing hole of the bottomed cylindrical molding material. A next container for radiation-contaminated materials is juxtaposed thereover. Then, a bottomed cylindrical molding material having a downwarded containing hole is covered to the container for the radiation-contaminated material in a state being protruded upwardly. The radiation-contaminated material is thus closed by a buffer material of the same material at the circumference thereof. (I.N.)

  16. Method for materials deposition by ablation transfer processing

    Science.gov (United States)

    Weiner, Kurt H.

    1996-01-01

    A method in which a thin layer of semiconducting, insulating, or metallic material is transferred by ablation from a source substrate, coated uniformly with a thin layer of said material, to a target substrate, where said material is desired, with a pulsed, high intensity, patternable beam of energy. The use of a patternable beam allows area-selective ablation from the source substrate resulting in additive deposition of the material onto the target substrate which may require a very low percentage of the area to be covered. Since material is placed only where it is required, material waste can be minimized by reusing the source substrate for depositions on multiple target substrates. Due to the use of a pulsed, high intensity energy source the target substrate remains at low temperature during the process, and thus low-temperature, low cost transparent glass or plastic can be used as the target substrate. The method can be carried out atmospheric pressures and at room temperatures, thus eliminating vacuum systems normally required in materials deposition processes. This invention has particular application in the flat panel display industry, as well as minimizing materials waste and associated costs.

  17. Temperature changes under demineralized dentin during polymerization of three resin-based restorative materials using QTH and LED units

    Directory of Open Access Journals (Sweden)

    Sayed-Mostafa Mousavinasab

    2014-08-01

    Full Text Available Objectives Light-curing of resin-based materials (RBMs increases the pulp chamber temperature, with detrimental effects on the vital pulp. This in vitro study compared the temperature rise under demineralized human tooth dentin during light-curing and the degrees of conversion (DCs of three different RBMs using quartz tungsten halogen (QTH and light-emitting diode (LED units (LCUs. Materials and Methods Demineralized and non-demineralized dentin disks were prepared from 120 extracted human mandibular molars. The temperature rise under the dentin disks (n = 12 during the light-curing of three RBMs, i.e. an Ormocer-based composite resin (Ceram. X, Dentsply DeTrey, a low-shrinkage silorane-based composite (Filtek P90, 3M ESPE, and a giomer (Beautifil II, Shofu GmbH, was measured with a K-type thermocouple wire. The DCs of the materials were investigated using Fourier transform infrared spectroscopy. Results The temperature rise under the demineralized dentin disks was higher than that under the non-demineralized dentin disks during the polymerization of all restorative materials (p 0.05. Conclusions Although there were no significant differences in the DCs, the temperature rise under demineralized dentin disks for the silorane-based composite was higher than that for dimethacrylate-based restorative materials, particularly with QTH LCU.

  18. Green Preparation of Epoxy/Graphene Oxide Nanocomposites Using a Glycidylamine Epoxy Resin as the Surface Modifier and Phase Transfer Agent of Graphene Oxide.

    Science.gov (United States)

    Tang, Xinlei; Zhou, Yang; Peng, Mao

    2016-01-27

    In studies of epoxy/graphene oxide (GO) nanocomposites, organic solvents are commonly used to disperse GO, and vigorous mechanical processes and complicated modification of GO are usually required, increasing the cost and hindering the development and application of epoxy nanocomposites. Here, we report a green, facile, and efficient method of preparing epoxy/GO nanocomposites. When triglycidyl para-aminophenol (TGPAP), a commercially available glycidyl amine epoxy resin with one tertiary amine group per molecule, is used as both the surface modifier and phase transfer agent of GO, GO can be directly and rapidly transferred from water to diglycidyl ether of bisphenol A and other types of epoxy resins by manual stirring under ambient conditions, whereas GO cannot be transferred to these epoxy resins in the absence of TGPAP. The interaction between TGPAP and GO and the effect of the TGPAP content on the dispersion of GO in the epoxy matrix were investigated systematically. Superior dispersion and exfoliation of GO nanosheets and remarkably improved mechanical properties, including tensile and flexural properties, toughness, storage modulus, and microhardness, of the epoxy/GO nanocomposites with a suitable amount of TGPAP were demonstrated. This method is organic-solvent-free and technically feasible for large-scale preparation of high-performance nanocomposites; it opens up new opportunities for exploiting the unique properties of graphene or even other nanofillers for a wide range of applications.

  19. Heat transfer characteristics of building walls using phase change material

    Science.gov (United States)

    Irsyad, M.; Pasek, A. D.; Indartono, Y. S.; Pratomo, A. W.

    2017-03-01

    Minimizing energy consumption in air conditioning system can be done with reducing the cooling load in a room. Heat from solar radiation which passes through the wall increases the cooling load. Utilization of phase change material on walls is expected to decrease the heat rate by storing energy when the phase change process takes place. The stored energy is released when the ambient temperature is low. Temperature differences at noon and evening can be utilized as discharging and charging cycles. This study examines the characteristics of heat transfer in walls using phase change material (PCM) in the form of encapsulation and using the sleeve as well. Heat transfer of bricks containing encapsulated PCM, tested the storage and released the heat on the walls of the building models were evaluated in this study. Experiments of heat transfer on brick consist of time that is needed for heat transfer and thermal conductivity test as well. Experiments were conducted on a wall coated by PCM which was exposed on a day and night cycle to analyze the heat storage and heat release. PCM used in these experiments was coconut oil. The measured parameter is the temperature at some points in the brick, walls and ambient temperature as well. The results showed that the use of encapsulation on an empty brick can increase the time for thermal heat transfer. Thermal conductivity values of a brick containing encapsulated PCM was lower than hollow bricks, where each value was 1.3 W/m.K and 1.6 W/m.K. While the process of heat absorption takes place from 7:00 am to 06:00 pm, and the release of heat runs from 10:00 pm to 7:00 am. The use of this PCM layer can reduce the surface temperature of the walls of an average of 2°C and slows the heat into the room.

  20. Polyimides Based on Asymmetric Dianhydrides (II) (a-BPDA vs a-BTDA) for Resin Transfer Molding (RTM)

    Science.gov (United States)

    Chuang, Kathy C.; Criss, Jim M.; Mintz, Eric A.

    2010-01-01

    A new series of low-melt viscosity imide resins (10-20 poise at 280 C) were formulated from asymmetric 2,3,3',4' -benzophenone dianhydride (a-BTDA) and 4-phenylethynylphthalic endcaps, along with 3,4' -oxydianiline, 3,3' -methylenedianiline and 3,3'- diaminobenzophenone, using a solvent-free melt process. a-BTDA RTM resins exhibited higher glass transition temperatures (Tg's = 330-400 C) compared to those prepared by asymmetric 2,3,3',4' -biphenyl dianhydride, (a-BPDA, Tg's = 320-370 C). These low-melt viscosity imide resins were fabricated into polyimide/T650-35 carbon fiber composites by a RTM process. Composites properties of a-BTDA resins, such as open-hole compression and short-beam shear strength, are compared to those of composites made from a-BPDA based resin at room temperature, 288 C and 315 C. These novel, high temperature RTM imide resins exhibit outstanding properties beyond the performance of conventional RTM resins, such as epoxy and BMI resins which have use-temperatures around 177 C and 232 C for aerospace applications.

  1. GC/MS analytical procedure for the characterization of glycerolipids, natural waxes, terpenoid resins, proteinaceous and polysaccharide materials in the same paint microsample avoiding interferences from inorganic media.

    Science.gov (United States)

    Lluveras, Anna; Bonaduce, Ilaria; Andreotti, Alessia; Colombini, Maria Perla

    2010-01-01

    An innovative GC/MS procedure for the characterization of organic materials in samples from works of art was developed. It is based on a multistep chemical pretreatment of the samples based on the ammonia extraction of proteins and polysaccharide materials, in order to separate them from lipid and resinous materials. The extraction is then followed by the separation and purification of proteinaceous and polysaccharide materials before hydrolysis, based on the use of monolithic sorbent tip technology with a C4 stationary phase. Lipids and resins are saponified/salified separately. Three fractions are generated and analyzed separately by GC/MS, thus enabling a quantitative analysis to be performed on aldoses and uronic acids, amino acids, mono- and dicarboxylic aliphatic acids, to determine polysaccharide, proteinaceous, and glycerolipid materials and molecular pattern recognition for the natural resin and wax components. With this analytical procedure, for the first time, glycerolipids, natural waxes, and proteinaceous, resinous, and polysaccharide materials can be simultaneously characterized in the same microsample from painted works of art. This new analytical approach prevents any analytical difficulties arising when the sample is divided into several different aliquots to be chemically processed separately, in order to characterize the various classes of organic materials. The procedure was successfully applied to samples from paintings from the Bamiyan Buddhas and a panel painting from the 15th century, highlighting the occurrence of glycerolipids, animal and plant resins, proteinaceous and polysaccharide materials.

  2. Shear bond strength of a denture base acrylic resin and gingiva-colored indirect composite material to zirconia ceramics.

    Science.gov (United States)

    Kubochi, Kei; Komine, Futoshi; Fushiki, Ryosuke; Yagawa, Shogo; Mori, Serina; Matsumura, Hideo

    2017-04-01

    To evaluate the shear bond strengths of two gingiva-colored materials (an indirect composite material and a denture base acrylic resin) to zirconia ceramics and determine the effects of surface treatment with various priming agents. A gingiva-colored indirect composite material (CER) or denture base acrylic resin (PAL) was bonded to zirconia disks with unpriming (UP) or one of seven priming agents (n=11 each), namely, Alloy Primer (ALP), Clearfil Photo Bond (CPB), Clearfil Photo Bond with Clearfil Porcelain Bond Activator (CPB+Act), Metal Link (MEL), Meta Fast Bonding Liner (MFB), MR. bond (MRB), and V-Primer (VPR). Shear bond strength was determined before and after 5000 thermocycles. The data were analyzed with the Kruskal-Wallis test and Steel-Dwass test. The mean pre-/post-thermalcycling bond strengths were 1.0-14.1MPa/0.1-12.1MPa for the CER specimen and 0.9-30.2MPa/0.1-11.1MPa for the PAL specimen. For the CER specimen, the ALP, CPB, and CPB+Act groups had significantly higher bond strengths among the eight groups, at both 0 and 5000 thermocycles. For the PAL specimen, shear bond strength was significantly lower after thermalcycling in all groups tested. After 5000 thermocycles, bond strengths were significantly higher in the CPB and CPB+Act groups than in the other groups. For the PAL specimens, bond strengths were significantly lower after thermalcycling in all groups tested. The MDP functional monomer improved bonding of a gingiva-colored indirect composite material and denture base acrylic resin to zirconia ceramics. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  3. Influence of surface pretreatment on the short-term bond strength of resin composite to a zirconia-based material.

    Science.gov (United States)

    Fazi, Giovanni; Vichi, Alessandro; Ferrari, Marco

    2012-04-01

    To evaluate the influence of airborne-particle abrasion of zirconia before and after sintering, on the bond strength between a zirconia core and an indirect resin composite material. 9 disks of Y-TZP zirconia core were prepared and divided into three equal groups. In Group 1 pre-sintered Y-TZP zirconia was airborne-particle abraded with 120 microm alumina oxide. In Group 2 sintered Y-TZP zirconia was airborne-particle abraded with 120 microm alumina oxide. In Group 3 sintered Y-TZP zirconia was not treated and thus served as the control group. A 10-methacryloylooxydecyldihydrogenphosphate (MDP) containing bonding agent and silane coupling agent mixture was applied to the disks in all three experimental groups. Resin composite for indirect restorations was incrementally layered in a plastic mold to a final thickness of 3 mm. Specimens were sectioned under water cooling to obtain microsticks 6 x 1 x 1 mm in dimension. 30 microsticks per experimental group were generated. Microtensile bond strength test was conducted with a universal testing machine. Fractured microsticks and sections from each group were also examined under an optical microscope and a scanning electron microscope to evaluate respectively the mode of failure and the zirconia-composite interface. T-test for independent samples was selected to analyze the data. The level of significance was set at P resin composite bond. Airborne-particle abrasion performed before sintering zirconia did not produce any significant differences.

  4. Experimental evaluation on natural convection heat transfer of microencapsulated phase change materials slurry in a rectangular heat storage tank

    International Nuclear Information System (INIS)

    Zhang Yanlai; Rao Zhonghao; Wang Shuangfeng; Zhang Zhao; Li Xiuping

    2012-01-01

    Highlights: ► It gives heat transfer characteristics in a rectangular heat storage tank as the basic unit for reservoir of thermal storage. ► Onset of natural convection gets easier for the MPCMS with a higher mass concentration. ► It enhances the heat transfer ability of natural convection for the MPCMS. ► Obtained the relationship between Ra and Nu of the MPCMS. - Abstract: The main purpose of this experiment is to evaluate natural convection heat transfer characteristics of microencapsulated PCM (phase change material) slurry (MPCMS) during phase change process in a rectangular heat storage tank heated from the bottom and cooled at the top. The microencapsulated PCM is several material compositions of n-paraffin waxes (mainly nonadecane) as the core materials, outside a layer of a melamine resin wrapped. In the present study, its slurry is used mixing with water. And the specific heat capacity with latent heat shows a peak value at the temperature of about T = 31 °C. We investigate the influences of the phase change process of the MPCMS on natural convection heat transfer. The experimental results indicate that phase change process of the MPCMS promote natural convection heat transfer. The local maximum heat transfer enhancement occurs at approximately T H = 34 °C corresponding to the heated plate temperature. With high mass concentration C m , the onset of natural convection gets easier for the MPCMS. The temperature gradient is larger near top plate and bottom plate of a rectangular heat storage tank. Heat transfer coefficient increases with the phase change of the PCM. And it summarizes that the phase change process of the PCM promote the occurrence of natural convection.

  5. Temperature changes under demineralized dentin during polymerization of three resin-based restorative materials using QTH and LED units.

    Science.gov (United States)

    Mousavinasab, Sayed-Mostafa; Khoroushi, Maryam; Moharreri, Mohammadreza; Atai, Mohammad

    2014-08-01

    Light-curing of resin-based materials (RBMs) increases the pulp chamber temperature, with detrimental effects on the vital pulp. This in vitro study compared the temperature rise under demineralized human tooth dentin during light-curing and the degrees of conversion (DCs) of three different RBMs using quartz tungsten halogen (QTH) and light-emitting diode (LED) units (LCUs). Demineralized and non-demineralized dentin disks were prepared from 120 extracted human mandibular molars. The temperature rise under the dentin disks (n = 12) during the light-curing of three RBMs, i.e. an Ormocer-based composite resin (Ceram. X, Dentsply DeTrey), a low-shrinkage silorane-based composite (Filtek P90, 3M ESPE), and a giomer (Beautifil II, Shofu GmbH), was measured with a K-type thermocouple wire. The DCs of the materials were investigated using Fourier transform infrared spectroscopy. The temperature rise under the demineralized dentin disks was higher than that under the non-demineralized dentin disks during the polymerization of all restorative materials (p 0.05). Although there were no significant differences in the DCs, the temperature rise under demineralized dentin disks for the silorane-based composite was higher than that for dimethacrylate-based restorative materials, particularly with QTH LCU.

  6. The stability of new transparent polymeric materials: The epoxy trimethoxyboroxine system. Part 1: The preparation, characterization and curing of epoxy resins and their copolymers

    Science.gov (United States)

    Pearce, E.; Lin, S. C.

    1981-01-01

    The effects of resin composition, curing conditions fillers, and flame retardant additives on the flammability of diglycidyl ether of bisphenol-A (DGEBA) as measured by the oxygen index is examined. The oxygen index of DGEBA cured with various curing agents was between 0.198 to 0.238. Fillers and flame retardant additives can increase the oxygen index dependent on the material and the amount used. Changes in the basic cured resin properties can be anticipated with the addition of noncompatible additives. High flame resistant epoxy resins with good stability and mechanical properties are investigated.

  7. Interaction of bullets with intermediate targets: material transfer and damage.

    Science.gov (United States)

    Vermeij, Erwin; Rijnders, Marco; Pieper, Pascal; Hermsen, Rob

    2012-11-30

    In complex shooting incidents, it is not always clear which bullet hit or eventually killed the victim and who fired it. The examination of traces of foreign material embedded in or adhered to bullets provides critical information in the trajectory reconstruction of spent bullets. Such a reconstruction can have considerable legal implications because it can prove that it was not someone's intention to kill. However, the microtraces that remain on spent bullets are often ignored. Microtraces on bullets, around bullet-holes and on ricochet marks were investigated using SEM/EDX for two different types of bullets: a relatively hard, full metal jacket (FMJ) bullet and a relatively soft, lead round-nose (LRN) bullet. A total of 179 bullets were fired into intermediate targets, sheets of 5 different materials (MDF, greenboard, gypsum fibreboard, glass and steel), at approximate incident angles of 90°, 10° and 5°. Of the 144 bullets fired at incident angles of 90°, 130 bullets perforated one of the materials, and 14 bullets perforated two of the materials. The 35 bullets fired at incident angles of 10° and 5° ricocheted off the intermediate targets, producing ricochet marks. In the majority of cases, traces from the target materials were found on the bullet, both after perforation and ricochet. The only exceptions were (1) the perforation of 9-mm sheets of MDF by FMJ bullets and (2) ricochet off glass when the glass did not break. Steel targets transfer small, but still detectable traces of iron to the bullet. The order in which targets are hit was reflected in the traces found on the bullets, i.e., materials from a secondary target were deposited on top of deposits from the primary target. This result implies that it is possible to determine the order of impact from the stratification of the material analysed. Traces from the bullets were found around all the bullet holes. Wipe-off from lead bullets is sometimes visible by the naked eye. Ricocheting bullets produce

  8. Resin composite repair: Quantitative microleakage evaluation of resin-resin and resin-tooth interfaces with different surface treatments

    OpenAIRE

    Celik, Cigdem; Cehreli, Sevi Burcak; Arhun, Neslihan

    2015-01-01

    Objective: The aim was to evaluate the effect of different adhesive systems and surface treatments on the integrity of resin-resin and resin-tooth interfaces after partial removal of preexisting resin composites using quantitative image analysis for microleakage testing protocol. Materials and Methods: A total of 80 human molar teeth were restored with either of the resin composites (Filtek Z250/GrandioSO) occlusally. The teeth were thermocycled (1000?). Mesial and distal 1/3 parts of the res...

  9. Influence of the base and diluent monomer on network characteristics and mechanical properties of neat resin and composite materials.

    Science.gov (United States)

    Fróes-Salgado, Nívea Regina de Godoy; Gajewski, Vinícius; Ornaghi, Bárbara Pick; Pfeifer, Carmem Silvia Costa; Meier, Marcia Margarete; Xavier, Tathy Aparecida; Braga, Roberto Ruggiero

    2015-05-01

    This study evaluated the effect of the combination of two dimethacrylate-based monomers [bisphenol A diglycidyl dimethacrylate (BisGMA) or bisphenol A ethoxylated dimethacrylate (BisEMA)] with diluents either derived from ethylene glycol dimethacrylate (ethylene glycol dimethacrylate, diethylene glycol dimethacrylate, triethylene glycol dimethacrylate, tetraethylene glycol dimethacrylate) or 1,10-decanediol dimethacrylate (D3MA) on network characteristics and mechanical properties of neat resin and composite materials. The degree of conversion, maximum rate of polymerization and water sorption/solubility of unfilled resins and the flexural strength and microhardness of composites (after 24 h storage in water and 3 months storage in a 75 vol% ethanol aqueous solution) were evaluated. Data were analyzed with two-way ANOVA and Tukey's test (α = 0.05). The higher conversion and lower water sorption presented by BisEMA co-polymers resulted in greater resistance to degradation in ethanol compared with BisGMA-based materials. In general, conversion and mechanical properties were optimized with the use of long-chain dimethacrylate derivatives of ethylene glycol. D3MA rendered more hydrophobic materials, but with relatively low conversion and mechanical properties.

  10. Influence of different surface treatments on bond strength of novel CAD/CAM restorative materials to resin cement

    Science.gov (United States)

    Kömürcüoğlu, Meltem Bektaş; Sağırkaya, Elçin

    2017-01-01

    PURPOSE To evaluate the effects of different surface treatments on the bond strength of novel CAD/CAM restorative materials to resin cement by four point bending test. MATERIALS AND METHODS The CAD/CAM materials under investigation were e.max CAD, Mark II, Lava Ultimate, and Enamic. A total of 400 bar specimens (4×1.2×12 mm) (n=10) milled from the CAD/CAM blocks underwent various pretreatments (no pretreatment (C), hydrofluoric acid (A), hydrofluoric acid + universal adhesive (Scotchbond) (AS), sandblasting (Sb), and sandblasting + universal adhesive (SbS)). The bars were luted end-to-end on the prepared surfaces with a dual curing adhesive resin cement (Variolink N, Ivoclar Vivadent) on the custom-made stainless steel mold. Ten test specimens for each treatment and material combination were performed with four point bending test method. Data were analyzed using ANOVA and Tukey's test. RESULTS The surface treatment and type of CAD/CAM restorative material showed a significant effect on the four point bending strength (FPBS) (P<.001). For LDC, AS surface treatment showed the highest FPBS results (100.31 ± 10.7 MPa) and the lowest values were obtained in RNC (23.63 ± 9.0 MPa) for control group. SEM analyses showed that the surface topography of CAD/CAM restorative materials was modified after treatments. CONCLUSION The surface treatment of sandblasting or HF acid etching in combination with a universal adhesive containing MDP can be suggested for the adhesive cementation of the novel CAD/CAM restorative materials. PMID:29279763

  11. Correlative imaging of fluorescent proteins in resin-embedded plant material.

    Science.gov (United States)

    Bell, Karen; Mitchell, Steve; Paultre, Danae; Posch, Markus; Oparka, Karl

    2013-04-01

    Fluorescent proteins (FPs) were developed for live-cell imaging and have revolutionized cell biology. However, not all plant tissues are accessible to live imaging using confocal microscopy, necessitating alternative approaches for protein localization. An example is the phloem, a tissue embedded deep within plant organs and sensitive to damage. To facilitate accurate localization of FPs within recalcitrant tissues, we developed a simple method for retaining FPs after resin embedding. This method is based on low-temperature fixation and dehydration, followed by embedding in London Resin White, and avoids the need for cryosections. We show that a palette of FPs can be localized in plant tissues while retaining good structural cell preservation, and that the polymerized block face can be counterstained with cell wall probes. Using this method we have been able to image green fluorescent protein-labeled plasmodesmata to a depth of more than 40 μm beneath the resin surface. Using correlative light and electron microscopy of the phloem, we were able to locate the same FP-labeled sieve elements in semithin and ultrathin sections. Sections were amenable to antibody labeling, and allowed a combination of confocal and superresolution imaging (three-dimensional-structured illumination microscopy) on the same cells. These correlative imaging methods should find several uses in plant cell biology.

  12. Process for affixing radioactive contamination on contaminated materials or wastes. Its application

    International Nuclear Information System (INIS)

    Aubouin, Guy; Aude, Georges; Tassigny, Christian de.

    1982-01-01

    The invention concerns a process for affixing radioactive contamination on materials or waste matter in order to ensure that the materials are transferred in complete safety or to package them when their activity is low. Under this process at least one coat of a resin polymerizable at ambient temperature, for example an epoxy resin, a polyester resin, a vinyl resin or a mixture of thermohardening resin and thermoplastic resin, is sprayed on to the contaminated material part by means of an electrostatic gun [fr

  13. Academy of Dental Materials guidance-Resin composites: Part II-Technique sensitivity (handling, polymerization, dimensional changes).

    Science.gov (United States)

    Ferracane, J L; Hilton, T J; Stansbury, J W; Watts, D C; Silikas, N; Ilie, N; Heintze, S; Cadenaro, M; Hickel, R

    2017-11-01

    The objective of this work, commissioned by the Academy of Dental Materials, was to review and critically appraise test methods to characterize properties related to critical issues for dental resin composites, including technique sensitivity and handling, polymerization, and dimensional stability, in order to provide specific guidance to investigators planning studies of these properties. The properties that relate to each of the main clinical issues identified were ranked in terms of their priority for testing, and the specific test methods within each property were ranked. An attempt was made to focus on the tests and methods likely to be the most useful, applicable, and supported by the literature, and where possible, those showing a correlation with clinical outcomes. Certain methods are only briefly mentioned to be all-inclusive. When a standard test method exists, whether from dentistry or another field, this test has been identified. Specific examples from the literature are included for each test method. The properties for evaluating resin composites were ranked in the priority of measurement as follows: (1) porosity, radiopacity, sensitivity to ambient light, degree of conversion, polymerization kinetics, depth of cure, polymerization shrinkage and rate, polymerization stress, and hygroscopic expansion; (2) stickiness, slump resistance, and viscosity; and (3) thermal expansion. The following guidance is meant to aid the researcher in choosing the most appropriate test methods when planning studies designed to assess certain key properties and characteristics of dental resin composites, specifically technique sensitivity and handling during placement, polymerization, and dimensional stability. Copyright © 2017 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  14. A resin composite material containing an eugenol derivative for intracanal post cementation and core build-up restoration.

    Science.gov (United States)

    Almaroof, A; Rojo, L; Mannocci, F; Deb, S

    2016-02-01

    To formulate and evaluate new dual cured resin composite based on the inclusion of eugenyl methacrylate monomer (EgMA) with Bis-GMA/TEGDMA resin systems for intracanal post cementation and core build-up restoration of endodontically treated teeth. EgMA was synthesized and incorporated at 5% (BTEg5) or 10% (BTEg10) into dual-cure formulations. Curing properties, viscosity, Tg, radiopacity, static and dynamic mechanical properties of the composites were determined and compared with Clearfil™DC Core-Plus, a commercial dual-cure, two-component composite. Statistical analysis of the data was performed with ANOVA and the Tukey's post-hoc test. The experimental composites were successfully prepared, which exhibited excellent curing depths of 4.9, 4.7 and 4.2 mm for BTEg0, BTEg5 and BTEg10 respectively, which were significantly higher than Clearfil™DC. However, the inclusion of EgMA initially led to a lower degree of cure, which increased when measured at 24 h with values comparable to formulations without EgMA, indicating post-curing. The inclusion of EgMA also lowered the polymerization exotherm thereby reducing the potential of thermal damage to host tissue. Both thermal and viscoelastic analyses confirmed the ability of the monomer to reduce the stiffness of the composites by forming a branched network. The compressive strength of BTEg5 was significantly higher than the control whilst flexural strength increased significantly from 95.9 to 114.8 MPa (BTEg5) and 121.9 MPa (BTEg10). Radiopacity of the composites was equivalent to ∼3 mm Al allowing efficient diagnosis. The incorporation of EgMA within polymerizable formulations provides a novel approach to prepare reinforced resin composite material for intracanal post cementation and core build-up and the potential to impart antibacterial properties of eugenol to endodontic restorations. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  15. Modeling of heat transfer within porous multi-constituent materials

    International Nuclear Information System (INIS)

    Niezgoda, M.

    2012-01-01

    The CEA works a great deal with porous materials - carbon composites, ceramics - and aims to optimize their properties for specific uses. These materials can be composed of several constituents and generally has a complex structure with pore size of several tens of micrometers. It is used in large-scale systems that are bigger than its own characteristic scale in which they are considered as equivalent to a homogeneous medium for the simulation of its behavior in its using environment without taking into account its local morphology. We are especially interested in the effective thermal diffusivity of heterogeneous materials that we estimate as a function of temperature with the help of an inverse method by considering they are homogeneous. The identification of the diffusivity of porous and/or semi-transparent materials is made difficult because of the strong conducto-radiative coupling can quickly occur when the temperature increases. We have thus modeled the coupled conductive and radiative heat transfer as a function of the temperature within porous multi-constituent materials from their morphology discretized into a set of homogeneous voxels. We have developed a methodology that consists in starting from a 3D-microstructure of the studied materials obtained by tomography. The microstructures constitute the numerical support to this modeling that renders it possible, on the one hand, to simulate any kind of numerical thermal experiments, especially the flash method whose the results render it possible to estimate the thermal diffusivity, and on the other hand, to reproduce the thermal behavior of our materials in their using conditions. (author) [fr

  16. Heat transfer in Rockwool modelling and method of measurement. The effect of natural convection on heat transfer in fibrous materials

    Energy Technology Data Exchange (ETDEWEB)

    Dyrboel, Susanne

    1998-05-01

    Fibrous materials are some of the most widely used materials for thermal insulation. In this project the focus of interest has been on fibrous materials for building application. Interest in improving the thermal properties of insulation materials is increasing as legislation is being tightened to reduce the overall energy consumption. A knowledge of the individual heat transfer mechanisms - whereby heat is transferred within a particular material is an essential tool to improve continuously the thermal properties of the material. Heat is transferred in fibrous materials by four different transfer mechanisms: conduction through air, conduction through fibres, thermal radiation and convection. In a particular temperature range the conduction through air can be regarded as a constant, and conduction through fibres is an insignificant part of the total heat transfer. Radiation, however, constitutes 25-40% of the total heat transfer in light fibrous materials. In Denmark and a number of other countries convection in fibrous materials is considered as non-existent when calculating heat transmission as well as when designing building structures. Two heat transfer mechanisms have been the focus of the current project: radiation heat transfer and convection. The radiation analysis serves to develop a model that can be used in further work to gain a wider knowledge of the way in which the morphology of the fibrous material, i.e. fibre diameter distribution, fibre orientation distribution etc., influences the radiation heat transfer under different conditions. The convection investigation serves to examine whether considering convection as non-existent is a fair assumption to use in present and future building structures. The assumption applied in practically is that convection makes a notable difference only in very thick insulation, at external temperatures below -20 deg. C, and at very low densities. For large thickness dimensions the resulting heat transfer through the

  17. Vibration damping and heat transfer using material phase changes

    Science.gov (United States)

    Kloucek, Petr [Houston, TX; Reynolds, Daniel R [Oakland, CA

    2009-03-24

    A method and apparatus wherein phase changes in a material can dampen vibrational energy, dampen noise and facilitate heat transfer. One embodiment includes a method for damping vibrational energy in a body. The method comprises attaching a material to the body, wherein the material comprises a substrate, a shape memory alloy layer, and a plurality of temperature change elements. The method further comprises sensing vibrations in the body. In addition, the method comprises indicating to at least a portion of the temperature change elements to provide a temperature change in the shape memory alloy layer, wherein the temperature change is sufficient to provide a phase change in at least a portion of the shape memory alloy layer, and further wherein the phase change consumes a sufficient amount of kinetic energy to dampen at least a portion of the vibrational energy in the body. In other embodiments, the shape memory alloy layer is a thin film. Additional embodiments include a sensor connected to the material.

  18. Vibration damping and heat transfer using material phase changes

    Science.gov (United States)

    Kloucek, Petr (Inventor); Reynolds, Daniel R. (Inventor)

    2009-01-01

    A method and apparatus wherein phase changes in a material can dampen vibrational energy, dampen noise and facilitate heat transfer. One embodiment includes a method for damping vibrational energy in a body. The method comprises attaching a material to the body, wherein the material comprises a substrate, a shape memory alloy layer, and a plurality of temperature change elements. The method further comprises sensing vibrations in the body. In addition, the method comprises indicating to at least a portion of the temperature change elements to provide a temperature change in the shape memory alloy layer, wherein the temperature change is sufficient to provide a phase change in at least a portion of the shape memory alloy layer, and further wherein the phase change consumes a sufficient amount of kinetic energy to dampen at least a portion of the vibrational energy in the body. In other embodiments, the shape memory alloy layer is a thin film. Additional embodiments include a sensor connected to the material.

  19. Efficacy of ceramic repair material on the bond strength of composite resin to zirconia ceramic.

    Science.gov (United States)

    Kirmali, Omer; Kapdan, Alper; Harorli, Osman Tolga; Barutcugil, Cagatay; Ozarslan, Mehmet Mustafa

    2015-01-01

    The aim of this study was to evaluate the shear bond strength of composite resin in five different repair systems. Sixty specimens (7 mm in diameter and 3 mm in height) of zirconia ceramic were fabricated. All specimen surfaces were prepared with a 30 µm fine diamond rotary cutting instrument with water irrigation for 10 s and dried with oil-free air. Specimens were then randomly divided into six groups for the following different intra-oral repair systems (n = 10): Group 1, control group; Group 2, Cojet system (3M ESPE, Seefeld, Germany); Group 3, Cimara® System (Voco, Cuxhaven, Germany); Group 4, Z-Prime Plus System (Bisco Inc., Schaumburg, IL); Group 5, Clearfil™ System (Kuraray, Osaka, Japan); and Group 6, Z-Bond System (Danville, CA). After surface conditioning, a composite resin Grandio (Voco, Cuxhaven, Germany) was applied to the zirconia surface using a cylindrical mold (5 mm in diameter and 3 mm in length) and incrementally filled up, according to the manufacturer's instructions of each intra-oral system. Each specimen was subjected to a shear load at a crosshead speed of 1 mm/min until fracture. One-way analysis of variance (ANOVA) and Tukey post-hoc tests were used to analyze the bond strength values. There were significant differences between Groups 2-6 and Group 1. The highest bond strength values were obtained with Group 2 (17.26 ± 3.22) and Group 3 (17.31 ± 3.62), while the lowest values were observed with Group 1 (8.96 ± 1.62) and Group 6 (12.85 ± 3.95). All repair systems tested increased the bond strength values between zirconia and composite resin that used surface grinding with a diamond bur.

  20. Improved resins and novel materials and methods for solid phase extraction and high performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Freeze, Ronald [Iowa State Univ., Ames, IA (United States)

    1997-10-08

    Solid-phase extraction (SPE) has grown to be one of the most widely used methods for isolation and preconcentration of a vast range of compounds from aqueous solutions. By modifying polymeric SPE resins with chelating functional groups, the selective uptake of metals was accomplished. The resin, along with adsorbed metals, was vaporized in the ICP and detection of the metals was then possible using either mass or emission spectroscopy. Drug analyses in biological fluids have received heightened attention as drug testing is on the increase both in sports and in the work environment. By using a direct-injection technique, biological fluids can be injected directly into the liquid chromatographic system with no pretreatment. A new surfactant, a sulfonated form of Brij-30 (Brij-S) is shown to prevent the uptake of serum proteins on commercial HPLC columns by forming a thin coating on the silica C18 surface. Excellent separations of eight or more drugs with a wide range of retention times were obtained. The separations had sharper peaks and lower retention times than similar separations performed with the surfactant sodium dodecylsulfate (SDS). Quantitative recovery of a number of drugs with limits of detection near 1 ppm with a 5 μl injection volume were obtained. Finally, a method for solid-phase extraction in a syringe is introduced. The system greatly reduced the volume of solvent required to elute adsorbed analytes from the SPE bed while providing a semi-automated setup. SPE in a syringe consists of a very small bed of resin-loaded membrane packed into a GC or HPLC syringe. After extraction, elution was performed with just a few μl of solvent. This small elution volume allowed injection of the eluent directly from the syringe into the chromatographic system, eliminating the handling problems associated with such small volumes.

  1. Efficiency of dual-cured resin cement polymerization induced by high-intensity LED curing units through ceramic material.

    Science.gov (United States)

    Watanabe, H; Kazama, Re; Asai, T; Kanaya, F; Ishizaki, H; Fukushima, M; Okiji, T

    2015-01-01

    This study aimed to evaluate the ability of high-intensity light-emitting diode (LED) and other curing units to cure dual-cured resin cement through ceramic material. A halogen curing unit (Jetlite 3000, Morita), a second-generation LED curing unit (Demi, Kerr), and two high-intensity LED curing units (PenCure 2000, Morita; Valo, Ultradent) were tested. Feldspathic ceramic plates (VITABLOCS Mark II, A3; Vita Zahnfabrik) with thicknesses of 1.0, 2.0, and 3.0 mm were prepared. Dual-cured resin cement samples (Clearfil Esthetic Cement, Kuraray Noritake Dental) were irradiated directly or through one of the ceramic plates for different periods (5, 10, 15, or 20 seconds for the high-intensity LED units and 20, 40, 60, or 80 seconds for the others). The Knoop hardness test was used to determine the level of photopolymerization that had been induced in the resin cement. Data were analyzed by one-way analysis of variance and Dunnett's post-hoc test to identify test-control (maximum irradiation without a ceramic plate) differences for each curing unit (presin cement through a ceramic plate resulted in decreased KHN values compared with direct irradiation. When the irradiation period was extended, only the LED units were able to achieve similar KHN values to those observed under direct irradiation in the presence of plates ≥2.0-mm thick. High-intensity LED units require a shorter irradiation period than halogen and second-generation LED curing units to obtain KHN values similar to those observed during direct irradiation.

  2. System for removing contaminants from plastic resin

    Science.gov (United States)

    Bohnert, George W.; Hand, Thomas E.; DeLaurentiis, Gary M.

    2010-11-23

    A resin recycling system that produces essentially contaminant-free synthetic resin material in an environmentally safe and economical manner. The system includes receiving the resin in container form. A grinder grinds the containers into resin particles. The particles are exposed to a solvent in one or more solvent wash vessels, the solvent contacting the resin particles and substantially removing contaminants on the resin particles. A separator is used to separate the resin particles and the solvent. The resin particles are then placed in solvent removing element where they are exposed to a solvent removing agent which removes any residual solvent remaining on the resin particles after separation.

  3. Bio-inspired Murray materials for mass transfer and activity

    Science.gov (United States)

    Zheng, Xianfeng; Shen, Guofang; Wang, Chao; Li, Yu; Dunphy, Darren; Hasan, Tawfique; Brinker, C. Jeffrey; Su, Bao-Lian

    2017-04-01

    Both plants and animals possess analogous tissues containing hierarchical networks of pores, with pore size ratios that have evolved to maximize mass transport and rates of reactions. The underlying physical principles of this optimized hierarchical design are embodied in Murray's law. However, we are yet to realize the benefit of mimicking nature's Murray networks in synthetic materials due to the challenges in fabricating vascularized structures. Here we emulate optimum natural systems following Murray's law using a bottom-up approach. Such bio-inspired materials, whose pore sizes decrease across multiple scales and finally terminate in size-invariant units like plant stems, leaf veins and vascular and respiratory systems provide hierarchical branching and precise diameter ratios for connecting multi-scale pores from macro to micro levels. Our Murray material mimics enable highly enhanced mass exchange and transfer in liquid-solid, gas-solid and electrochemical reactions and exhibit enhanced performance in photocatalysis, gas sensing and as Li-ion battery electrodes.

  4. Microleakage of composite resin and amalgam core material under complete cast crowns.

    Science.gov (United States)

    Larson, T D; Jensen, J R

    1980-07-01

    Ninety extracted human teeth were used to compare the microleakage of composite resin over, amalgam core, and regular crown preparations under a complete cast gold crown cemented with zinc phosphate cement as determined by 2% fluorescein dye solution. Specimens were compared with and without aging after cementation in a thermal bath by cycling some of them between 4 degrees C and 60 degrees C in a 2% fluorescein dye bath and others in a similar bath held at 37 degrees C. Fluorescein dye (under ultraviolet light) demonstrated microleakage of the specimens between the crown-tooth interface and the core-tooth interface. There were no significant differences in the microleakage due to aging. The specimens held at 37 degrees C in the fluorescein dye bath showed no significant differences between the core preparations and the regular crown preparations. However, when specimens were thermally cycled between 4 degrees C and 60 degrees C, there were significant differences. With thermal cycling, the regular crown preparations were better able to resist microleakage at the crown-tooth interface than either the composite resin core or the amalgam core preparations. The results of this investigation seem to indicate a need for further evaluation of core build-ups under cemented complete gold crowns.

  5. Physicochemical properties and cytotoxicity of an experimental resin-based pulp capping material containing the quaternary ammonium salt and Portland cement.

    Science.gov (United States)

    Yang, Y W; Yu, F; Zhang, H C; Dong, Y; Qiu, Y N; Jiao, Y; Xing, X D; Tian, M; Huang, L; Chen, J H

    2018-01-01

    To evaluate in vitro the physicochemical properties, cytotoxicity and calcium phosphate nucleation of an experimental light-curable pulp capping material composed of a resin with antibacterial monomer (MAE-DB) and Portland cement (PC). The experimental material was prepared by mixing PC with a resin containing MAE-DB at a 2 : 1 ratio. Cured pure resin containing MAE-DB served as control resin. ProRoot MTA and Dycal served as commercial controls. The depth of cure, degree of monomer conversion, water absorption and solubility of dry samples, calcium release, alkalinizing activity, calcium phosphate nucleation and the cytotoxicity of materials were evaluated. Statistical analysis was carried out using anova followed by Tukey's HSD test (equal variance assumed) or Tamhane test (equal variance not assumed) and independent-samples t-tests. The experimental material had a cure depth of 1.19 mm, and the mean degree of monomer conversion was 70.93% immediately post-cure and 88.75% at 24 h post-cure. The water absorption of the experimental material was between those of MTA and Dycal, and its solubility was significantly less (P material exhibited continuous calcium release and an alkalinizing power between those of MTA and Dycal throughout the test period. Freshly set experimental material, control resin and all 24-h set materials had acceptable cytotoxicity. The experimental material, MTA and Dycal all exhibited the formation of apatite precipitates after immersion in phosphate-buffered saline. The experimental material possessed adequate physicochemical properties, low cytotoxicity and good calcium phosphate nucleation. © 2017 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  6. Addition of glass fibers and titanium dioxide nanoparticles to the acrylic resin denture base material: comparative study with the conventional and high impact types.

    Science.gov (United States)

    Hamouda, Ibrahim M; Beyari, Mohammed M

    2014-03-01

    The aim of this study was to clarify the effect of addition of glass fibers and titanium dioxide nanoparticles to the conventional acrylic resin. The tested parameters were monomer release, deflection at fracture, flexural strength, flexural modulus, and toughness. The modified acrylic resin groups were compared to the conventional unmodified and high impact types. The correlation between the tested material properties was also evaluated. The materials used were conventional unmodified and high impact acrylic resins. The conventional acrylic resin was modified using 5% glass fibers and 5% titanium dioxide nanoparticles. Specimens were prepared according to the manufacturer's instructions and American Dental Association Specification No. 12. Monomer release was measured using isocratic high-performance liquid chromatography. Deflection at fracture, flexural strength, and flexural modulus were measured using three point-bending test with a universal testing machine. The toughness was related to the total area under the load-deflection curve up to the breaking point. The correlation between the tested properties was clarified. All materials released monomer with varying values. The tested materials exhibited comparable values of deflection at fracture. Specimens modified with glass-fibers showed improved flexural strength and toughness similar to that of the high impact acrylic resin. Specimens modified with titanium dioxide nanoparticles exhibited reduction in the flexural properties and toughness. No significant changes were observed in the flexural modulus. There were positive correlations between the flexural strength, flexural modulus and toughness. On the contrary, there was negative correlation between deflection at fracture and flexural modulus. The most commercially successful method for reinforcement to date is the rubber toughening. The conventional acrylic resin denture base material could be reinforced by glass fibers while titanium dioxide nanoparticles

  7. Increasing Boiling Heat Transfer using Low Conductivity Materials

    Science.gov (United States)

    Mahamudur Rahman, Md; Pollack, Jordan; McCarthy, Matthew

    2015-08-01

    We report the counterintuitive mechanism of increasing boiling heat transfer by incorporating low-conductivity materials at the interface between the surface and fluid. By embedding an array of non-conductive lines into a high-conductivity substrate, in-plane variations in the local surface temperature are created. During boiling the surface temperature varies spatially across the substrate, alternating between high and low values, and promotes the organization of distinct liquid and vapor flows. By systematically tuning the peak-to-peak wavelength of this spatial temperature variation, a resonance-like effect is seen at a value equal to the capillary length of the fluid. Replacing ~18% of the surface with a non-conductive epoxy results in a greater than 5x increase in heat transfer rate at a given superheat temperature. This drastic and counterintuitive increase is shown to be due to optimized bubble dynamics, where ordered pathways allow for efficient removal of vapor and the return of replenishing liquid. The use of engineered thermal gradients represents a potentially disruptive approach to create high-efficiency and high-heat-flux boiling surfaces which are naturally insensitive to fouling and degradation as compared to other approaches.

  8. Increasing Boiling Heat Transfer using Low Conductivity Materials.

    Science.gov (United States)

    Rahman, Md Mahamudur; Pollack, Jordan; McCarthy, Matthew

    2015-08-18

    We report the counterintuitive mechanism of increasing boiling heat transfer by incorporating low-conductivity materials at the interface between the surface and fluid. By embedding an array of non-conductive lines into a high-conductivity substrate, in-plane variations in the local surface temperature are created. During boiling the surface temperature varies spatially across the substrate, alternating between high and low values, and promotes the organization of distinct liquid and vapor flows. By systematically tuning the peak-to-peak wavelength of this spatial temperature variation, a resonance-like effect is seen at a value equal to the capillary length of the fluid. Replacing ~18% of the surface with a non-conductive epoxy results in a greater than 5x increase in heat transfer rate at a given superheat temperature. This drastic and counterintuitive increase is shown to be due to optimized bubble dynamics, where ordered pathways allow for efficient removal of vapor and the return of replenishing liquid. The use of engineered thermal gradients represents a potentially disruptive approach to create high-efficiency and high-heat-flux boiling surfaces which are naturally insensitive to fouling and degradation as compared to other approaches.

  9. Molten Materials Transfer and Handling on the Lunar Surface

    Science.gov (United States)

    Stefanescu, Doru M.; Curreri, Peter A.; Sen, Subhayu

    2008-01-01

    Electrolytic reduction processes as a means to provide pure elements for lunar resource utilization have many advantages. Such processes have. the potential of removing all the oxygen from the lunar soil for use in life support and for propellant. Electrochemical reduction also provides a direct path for the. production of pure metals and silicon which can be utilized for in situ manufacturing and power production. Some of the challenges encountered in the electrolytic reduction processes include the feeding of the electrolytic cell (the transfer of electrolyte containing lunar soil), the withdrawal of reactants and refined products such as the liquidironsiliconalloy with a number of impurities, and the spent regolith slag, produced in the hot electrolytic cell for the reduction of lunar regolith. The paper will discuss some of the possible solutions to the challenges of handling molten materials on the lunar surface, as well as the path toward the construction and testing of a proof-of-concept facility.

  10. Multi-wall carbon nanotubes/epoxy resin composites characterization of the starting materials and evaluation of thermal and electrical conductivity

    International Nuclear Information System (INIS)

    Silva, Wellington Marcos da

    2009-01-01

    In this study we investigate the electrical and thermal properties of I) composite materials fabricated with O, I, 0,5 and I wt% of concentric multi-wall carbon nanotubes/epoxy resin (MWNT) dispersed randomly in the resin; 2) MWNT buckypaper/resin composite materials; 3) and neat MWNT buckypaper. Initially, we use the techniques of thermogravimetry, infrared spectroscopy, nuclear magnetic resonance, energy dispersive spectroscopy, x-ray fluorescence, scanning and transmission electron microscopy for a broadening characterization of the starting materials, to evaluate its morphology, purity, chemical composition and structure, in order to optimize the properties of crosslinked resin and, consequently, of the composite systems. Important parameters such as the average molecular mass and the equivalent weight of epoxy resin (DGEBA) were determined by 1 H-NMR analysis and, after that, resin/curing agent relations with Phr 10, 15, 20 and 53,2 were elaborated and investigated by thermogravimetry, the resin/curing agent relation with Phr 10 showed to be the most thermally stable. This stoichiometric relation was used to elaborate the composites. We have evaluated that the effect of adding 10 wt% of the solvent acetone to the epoxy resin preparation does not alter its properties so we have adopted two routes to fabricate the composites. In the first route we used 10 wt% of acetone and, in the second the MWNT were dispersed in the matrix without using the solvent. However, no significant difference was observed for the dispersion of the bundle tubes in both systems. The electrical conductivity of the composites and buckypapers was evaluated by impedance spectroscopy and the thermal conductivity by the flash laser flash method. Only the buckypapers presented high values for electrical conductivity (10 3 S.m -1 ). The composite systems presented values of 10 -3 S.m -1 , only a bit different from the value of the crosslinked resin. For thermal conductivity, the values for the

  11. Effect of light-curing method and indirect veneering materials on the Knoop hardness of a resin cement

    Directory of Open Access Journals (Sweden)

    Nelson Tetsu Iriyama

    2009-06-01

    Full Text Available This study evaluated the Knoop hardness of a dual-cured resin cement (Rely-X ARC activated solely by chemical reaction (control group or by chemical / physical mode, light-cured through a 1.5 mm thick ceramic (HeraCeram or composite (Artglass disc. Light curing was carried out using conventional halogen light (XL2500 for 40 s (QTH; light emitting diodes (Ultrablue Is for 40 s (LED; and Xenon plasma arc (Apollo 95E for 3 s (PAC. Bovine incisors had their buccal face flattened and hybridized. On this surface a rubber mold (5 mm in diameter and 1 mm in height was bulk filled with the resin cement. A polyester strip was seated for direct light curing or through the discs of veneering materials. After dry storage in the dark (24 h 37°C, the samples (n = 5 were sectioned for hardness (KHN measurements, taken in a microhardness tester (50 gF load 15 s. The data were statistically analyzed by ANOVA and Tukey's test (α = 0.05. The cement presented higher Knoop hardness values with Artglass for QTH and LED, compared to HeraCeram. The control group and the PAC/Artglass group showed lower hardness values compared to the groups light-cured with QTH and LED. PAC/HeraCeram resulted in the worst combination for cement hardness values.

  12. Six-month evaluation of a resin/dentin interface created by methacrylate and silorane-based materials

    Science.gov (United States)

    SAMPAIO, Renata Kirita Doi; WANG, Linda; de CARVALHO, Rodrigo Varella; GARCIA, Eugenio José; de ANDRADE, Andréa Mello; KLEIN-JÚNIOR, Celso Afonso; GRANDE, Rosa Helena Miranda; MOURA, Sandra Kiss

    2013-01-01

    Objectives: This study aimed to compare the micro-tensile bond strength of methacrylate resin systems to a silorane-based restorative system on dentin after 24 hours and six months water storage. Material and Methods: The restorative systems Adper Single Bond 2/Filtek Z350 (ASB), Clearfil SE Bond/Z350 (CF), Adper SE Plus/Z350 (ASEP) and P90 Adhesive System/Filtek P90 (P90) were applied on flat dentin surfaces of 20 third molars (n=5). The restored teeth were sectioned perpendicularly to the bonding interface to obtain sticks (0.8 mm2) to be tested after 24 hours (24 h) and 6 months (6 m) of water storage, in a universal testing machine at 0.5 mm/min. The data was analyzed via two-way Analysis of Variance/Bonferroni post hoc tests at 5% global significance. Results: Overall outcomes did not indicate a statistical difference for the resin systems (p=0.26) nor time (p=0.62). No interaction between material x time was detected (p=0.28). Mean standard-deviation in MPa at 24 h and 6 m were: ASB 31.38 (4.53) and 30.06 (1.95), CF 34.26 (3.47) and 32.75 (4.18), ASEP 29.54 (4.14) and 33.47 (2.47), P90 30.27 (2.03) and 31.34 (2.19). Conclusions: The silorane-based system showed a similar performance to methacrylate-based materials on dentin. All systems were stable in terms of bond strength up to 6 month of water storage. PMID:23559117

  13. Six-month evaluation of a resin/dentin interface created by methacrylate and silorane-based materials

    Directory of Open Access Journals (Sweden)

    Renata Kirita Doi SAMPAIO

    2013-01-01

    Full Text Available Objectives This study aimed to compare the micro-tensile bond strength of methacrylate resin systems to a silorane-based restorative system on dentin after 24 hours and six months water storage. Material and Methods The restorative systems Adper Single Bond 2/Filtek Z350 (ASB, Clearfil SE Bond/Z350 (CF, Adper SE Plus/Z350 (ASEP and P90 Adhesive System/Filtek P90 (P90 were applied on flat dentin surfaces of 20 third molars (n=5. The restored teeth were sectioned perpendicularly to the bonding interface to obtain sticks (0.8 mm2 to be tested after 24 hours (24 h and 6 months (6 m of water storage, in a universal testing machine at 0.5 mm/min. The data was analyzed via two-way Analysis of Variance/Bonferroni post hoc tests at 5% global significance. Results Overall outcomes did not indicate a statistical difference for the resin systems (p=0.26 nor time (p=0.62. No interaction between material × time was detected (p=0.28. Mean standard-deviation in MPa at 24 h and 6 m were: ASB 31.38 (4.53 and 30.06 (1.95, CF 34.26 (3.47 and 32.75 (4.18, ASEP 29.54 (4.14 and 33.47 (2.47, P90 30.27 (2.03 and 31.34 (2.19. Conclusions The silorane-based system showed a similar performance to methacrylate-based materials on dentin. All systems were stable in terms of bond strength up to 6 month of water storage.

  14. Perubahan warna lempeng resin akrilik yang direndam dalam larutan desinfektan sodium hipoklorit dan klorhexidin (The color changes of acrylic resins denture base material which are immersed in Sodium hypochlorite and chlorhexidine

    Directory of Open Access Journals (Sweden)

    David David

    2006-03-01

    Full Text Available One of the acrylic resins properties is the water absorption including color fluids and chemically fluids that affect on the color changes of the acrylic resins. This laboratory experiments studied sodium hypochlorite and chlorhexidine effect on the color changes of acrylic denture base resins material. The study was conducted by immersing heat cured acrylic plate samples of 26 mm of diameter and 0.4 mm of thickness in sodium hypochlorite for 10; 70 and 140 minutes and chlorhexidine for 15; 105 and 210 minutes. Seven samples were used for each experiment. An optical spectrometer BPX-47 type photo cell and a digital microvoltage were used for the color changes observation. The statistical test used were t-test, One-way ANOVA and LSD with 0.05 significance degree level. The results of the studied showed that the color of acrylic resins denture base plate changed after immersion in sodium hypochlorite for 70 and 140 minutes and chlorhexidine for 105 and 210 minute of immersion.

  15. Energy transfer phenomena and radiative processes in silicon nitride based materials for on-chip photonics applications

    Science.gov (United States)

    Li, Rui

    Rare-earth (RE) doping of silicon-based structures provides a valuable approach for light-emitting devices which could be monolithically integrated atop the widespread silicon electronics platform and enables inexpensive integration of on-chip optical components. However, the small excitable fraction of RE ions and the substantial free carrier losses in Si nanostructures severely limit the possibility to achieve net optical gain using traditional Er doped materials, such as Er doped Si-rich oxides (Er:SRO). On the other hand, a novel material platform based on RE-doped silicon nitride (RE:Six) materials has recently revealed unique advantages for on-chip light source. Based on a variety of light emission spectroscopic techniques and rate equation modeling, light emission and energy transfer phenomena were studied to quantitatively assess the benefits of the novel Er and Nd doped SiNx (Er: SiN x and Nd:SiNx) material platform compared to the standard Er:SRO. Efficient energy transfer and nanosecond-time dynamics from SiN x matrices to RE ions with two orders of magnitude larger coupling coefficient than Er:SRO were demonstrated for the first time. The origin of this energy transfer was shown to consist of non-resonant phonon-mediated coupling by temperature-dependent experiments. In addition, a tradeoff between excitation efficiency by energy transfer and emission efficiency, determined by excess Si concentration, was discovered and studied. Although carrier absorption and non-radiative recombination jeopardize the observation of optical gain, differential loss measurements under femtosecond pulsed excitation resulted in the bleaching of the Er ground state absorption by energy transfer in Er:SiN x materials, which bears great hope for the engineering of Si-based lasers. On the other hand, with a superior 4-level system, Nd:SiNx is promising to lase with a lower threshold. To make use of the better field confinement in SiNx due to its higher refractive index, RE:SiN

  16. Comparative evaluation of shear bond strength of three resin based dual-cure core build-up materials: An In-vitro study

    OpenAIRE

    Jain, Gaurav; Narad, Aditi; Boruah, Lalit C.; Rajkumar, Balakrishnan

    2015-01-01

    Aim: The in-vitro study compared the shear bond strength (SBS) of three recently introduced dual-cure resin based core build-up materials namely ParaCore, FluoroCore, and MultiCore. Materials and Methods: One hundred twenty extracted permanent human mandibular molar teeth were taken and sectioned horizontally beneath the dentinoenamel junction to expose the coronal dentin. The specimens obtained were divided into three main groups based on the materials used and then further divided into ...

  17. In vitro antibacterial activity of a novel resin-based pulp capping material containing the quaternary ammonium salt MAE-DB and Portland cement.

    Science.gov (United States)

    Yang, Yanwei; Huang, Li; Dong, Yan; Zhang, Hongchen; Zhou, Wei; Ban, Jinghao; Wei, Jingjing; Liu, Yan; Gao, Jing; Chen, Jihua

    2014-01-01

    Vital pulp preservation in the treatment of deep caries is challenging due to bacterial infection. The objectives of this study were to synthesize a novel, light-cured composite material containing bioactive calcium-silicate (Portland cement, PC) and the antimicrobial quaternary ammonium salt monomer 2-methacryloxylethyl dodecyl methyl ammonium bromide (MAE-DB) and to evaluate its effects on Streptococcus mutans growth in vitro. The experimental material was prepared from a 2 : 1 ratio of PC mixed with a resin of 2-hydroxyethylmethacrylate, bisphenol glycerolate dimethacrylate, and triethylene glycol dimethacrylate (4 : 3 : 1) containing 5 wt% MAE-DB. Cured resin containing 5% MAE-DB without PC served as the positive control material, and resin without MAE-DB or PC served as the negative control material. Mineral trioxide aggregate (MTA) and calcium hydroxide (Dycal) served as commercial controls. S. mutans biofilm formation on material surfaces and growth in the culture medium were tested according to colony-forming units (CFUs) and metabolic activity after 24 h incubation over freshly prepared samples or samples aged in water for 6 months. Biofilm formation was also assessed by Live/Dead staining and scanning electron microscopy. S. mutans biofilm formation on the experimental material was significantly inhibited, with CFU counts, metabolic activity, viability staining, and morphology similar to those of biofilms on the positive control material. None of the materials affected bacterial growth in solution. Contact-inhibition of biofilm formation was retained by the aged experimental material. Significant biofilm formation was observed on MTA and Dycal. The synthesized material containing HEMA-BisGMA-TEGDMA resin with MAE-DB as the antimicrobial agent and PC to support mineralized tissue formation inhibited S. mutans biofilm formation even after aging in water for 6 months, but had no inhibitory effect on bacteria in solution. Therefore, this material shows

  18. Effect of priming agents on shear bond strengths of resin-based luting agents to a translucent zirconia material.

    Science.gov (United States)

    Yagawa, Shogo; Komine, Futoshi; Fushiki, Ryosuke; Kubochi, Kei; Kimura, Fumiaki; Matsumura, Hideo

    2017-09-19

    The purpose of the present study was to evaluate the effect of priming agents and artificial aging with thermocycling on shear bond strengths of two resin-based luting agents to a translucent zirconia material. A total of 308 pairs of translucent zirconia disk specimens were divided into seven treatment groups: Alloy Primer (ALP), Clearfil Ceramic Primer Plus (CCP), Meta Fast Bonding Liner (MFB), MR. bond (MRB), Super-Bond PZ Primer Liquid B (PZB), V-Primer (VPR), and an unprimed group (UP). The specimens in each group were bonded with Panavia V5 Universal (UNI) and Opaque shade (OPA). Shear bond strengths (n=11 each) were tested before and after 5000 thermocycles. The data were analyzed with the Kruskal-Wallis test and the Steel-Dwass test. For both 0 and 5000 thermocycles, the ALP (47.8 and 41.5MPa, respectively) and CCP (45.8 and 42.3MPa, respectively) groups showed significantly higher bond strengths than other groups in the UNI luting agent. For the OPA luting agent, CCP group (45.8MPa) exhibited the highest pre-thermocycling bond strength in all groups. The ALP (32.4MPa) and CCP (36.5MPa) groups had significantly higher post-thermocycling shear bond strengths than other groups. In several groups, the shear bond strengths of the UNI luting agent were significantly higher than those of the OPA luting agent before and after thermocycling. Application of priming agents containing hydrophobic phosphate monomer (MDP) yielded the durable bond strengths of resin-based luting agents to a translucent zirconia material. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  19. 10 CFR 73.28 - Security background checks for secure transfer of nuclear materials.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Security background checks for secure transfer of nuclear... PLANTS AND MATERIALS Physical Protection of Special Nuclear Material in Transit § 73.28 Security background checks for secure transfer of nuclear materials. Licensees are excepted from the security...

  20. Fracture Resistance of Endodontically Treated Teeth Restored with 2 Different Fiber-reinforced Composite and 2 Conventional Composite Resin Core Buildup Materials: An In Vitro Study.

    Science.gov (United States)

    Eapen, Ashly Mary; Amirtharaj, L Vijay; Sanjeev, Kavitha; Mahalaxmi, Sekar

    2017-09-01

    The purpose of this in vitro study was to comparatively evaluate the fracture resistance of endodontically treated teeth restored with 2 fiber-reinforced composite resins and 2 conventional composite resin core buildup materials. Sixty noncarious unrestored human maxillary premolars were collected, endodontically treated (except group 1, negative control), and randomly divided into 5 groups (n = 10). Group 2 was the positive control. The remaining 40 prepared teeth were restored with various direct core buildup materials as follows: group 3 teeth were restored with dual-cure composite resin, group 4 with posterior composite resin, group 5 with fiber-reinforced composite resin, and group 6 with short fiber-reinforced composite resin. Fracture strength testing was performed using a universal testing machine. The results were statistically analyzed by 1-way analysis of variance and the post hoc Tukey test. Fracture patterns for each sample were also examined under a light microscope to determine the level of fractures. The mean fracture resistance values (in newtons) were obtained as group 1 > group 6 > group 4 > group 3 > group 5 > group 2. Group 6 showed the highest mean fracture resistance value, which was significantly higher than the other experimental groups, and all the fractures occurred at the level of enamel. Within the limitations of this study, a short fiber-reinforced composite can be used as a direct core buildup material that can effectively resist heavy occlusal forces against fracture and may reinforce the remaining tooth structure in endodontically treated teeth. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  1. Method of heat decomposition for chemical decontaminating resin waste

    International Nuclear Information System (INIS)

    Kikuchi, Akira.

    1988-01-01

    Purpose: To make resin wastes into non-deleterious state, discharge them into a resin waste storage tank of existent radioactive waste processing facility and store and dispose them. Constitution: In the processing of chemical decontaminating resin wastes, iron exchange resins adsorbing chemical decontaminating agents comprising a solution of citric acid, oxalic acid, formic acid and EDTA alone or as a mixture of them are heated to dry, thermally decomposed and then separated from the ion exchange resins. That is, the main ingredients of the chemical decontaminating agents are heat-decomposed when heated and dried at about 250 deg C in air and converted into non-toxic gases such as CO, CO 2 , NO, NO 2 or H 2 O. Further, since combustion or carbonization of the basic materials for the resin is not caused at such a level of temperature, the resin wastes removed with organic acid and chelating agents are transferred to an existent resin waste storage tank and stored therein. In this way, facility cost and radiation exposure can remarkably be decreased. (Kamimura, M.)

  2. Biosurfactants prevent in vitro Candida albicans biofilm formation on resins and silicon materials for prosthetic devices.

    Science.gov (United States)

    Cochis, Andrea; Fracchia, Letizia; Martinotti, Maria Giovanna; Rimondini, Lia

    2012-06-01

    The aim of this study was to evaluate in vitro the preventive antiadhesion activity of biosurfactants against Candida albicans biofilm. Disks of silicon and acrylic resin for denture prostheses were precoated with increasing concentrations of biosurfactants obtained from endophyte biofilms selected from Robinia pseudoacacia and from Nerium oleander, and afterward infected with C. albicans cells. The number of biofilm cells were detected by colony-forming unit (CFU) counting, cell viability was established by the 2,3-bis(2-methoxy-4-nitro-5-sulphophenyl)-5-[(phenyl amino)carbonyl]-2H-tetrazolium hydroxide (XTT) assay, and biosurfactant cytotoxicity was evaluated by the [3-(4,5-dimethyliazol-2-yl)-5-(3-carboxymethoxyphenyl)-2-(4-sulphophenyl)-2H-tetrazolium] (MTT) assay. Chlorhexidine was used as control. Precoating with biosurfactants caused a greater reduction (P biosurfactants was observed at low concentrations (78.12 μg/mL and 156.12 μg/mL) which were noncytotoxic. This study demonstrated the preventive antiadhesion activity of biosurfactants against C. albicans biofilm. These agents are amphiphilic, interfere with microbial adhesion, and demonstrate cycompatibility with epithelial cells and fibroblasts. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Influence of different luting protocols on shear bond strength of computer aided design/computer aided manufacturing resin nanoceramic material to dentin.

    Science.gov (United States)

    Poggio, Claudio; Pigozzo, Marco; Ceci, Matteo; Scribante, Andrea; Beltrami, Riccardo; Chiesa, Marco

    2016-01-01

    The purpose of this study was to evaluate the influence of three different luting protocols on shear bond strength of computer aided design/computer aided manufacturing (CAD/CAM) resin nanoceramic (RNC) material to dentin. In this in vitro study, 30 disks were milled from RNC blocks (Lava Ultimate/3M ESPE) with CAD/CAM technology. The disks were subsequently cemented to the exposed dentin of 30 recently extracted bovine permanent mandibular incisors. The specimens were randomly assigned into 3 groups of 10 teeth each. In Group 1, disks were cemented using a total-etch protocol (Scotchbond™ Universal Etchant phosphoric acid + Scotchbond Universal Adhesive + RelyX™ Ultimate conventional resin cement); in Group 2, disks were cemented using a self-etch protocol (Scotchbond Universal Adhesive + RelyX™ Ultimate conventional resin cement); in Group 3, disks were cemented using a self-adhesive protocol (RelyX™ Unicem 2 Automix self-adhesive resin cement). All cemented specimens were placed in a universal testing machine (Instron Universal Testing Machine 3343) and submitted to a shear bond strength test to check the strength of adhesion between the two substrates, dentin, and RNC disks. Specimens were stressed at a crosshead speed of 1 mm/min. Data were analyzed with analysis of variance and post-hoc Tukey's test at a level of significance of 0.05. Post-hoc Tukey testing showed that the highest shear strength values (P resin cements (coupled with etch and rinse or self-etch adhesives) showed better shear strength values compared to self-adhesive resin cements. Furthermore, conventional resin cements used together with a self-etch adhesive reported the highest values of adhesion.

  4. Cashew nut shell liquid resin used as matrix for compound materials; O LCC (Liquido da castanha do caju) como matriz em materiais compostos

    Energy Technology Data Exchange (ETDEWEB)

    Abreu, Hamilton Ferreira Gomes de; Nogueira, Ricardo Emilio Ferreira Quevedo [Ceara Univ., Fortaleza, CE (Brazil). Dept. de Engenharia Mecanica

    1996-12-31

    Cashew nut shell liquid resin a by product of cashew processing industry is a naturally occurring phenol of low cost and are used in Brazil as fuel in the industrial production of cashew nut or as a structural material when associated with coconut fiber or rice shell. A high measured Tg points to noble applications. This paper presents some properties of LCC resin and concludes that it has good perspectives as a composite matrice to work at elevated temperatures. (author) 5 refs., 4 figs., 2 tabs.

  5. Color stability of nano-filled, micro-hybrid, and silorane-based dental composite resin materials

    Directory of Open Access Journals (Sweden)

    Mohsen Saud M ALShetili

    2016-01-01

    Full Text Available Aim: The purpose of this study was to investigate the color stability of nano-hybrid, micro-hybrid, and silorane-based composite resin restorative materials upon exposure to staining agents. Materials and Methods: One hundred twenty composites samples were prepared, 40 from each composite material (Filtek ® Z350, Filtek ® P90, and Filtek ® Z250. The specimens were randomly divided into four groups (10 of each sample. The specimens were incubated for 24 h in distilled water and then for 72 h in corresponding mediums (distilled water, red grape juice, green tea, coffee. The color of all the specimens was assessed before and after exposure with a spectrophotometer and total color change (ΔE was calculated using ΔEFNx01 = [(ΔLFNx012 + (ΔaFNx012 + (ΔbFNx012]1/2. The data were analyzed with one-way analysis of variance (ANOVA and Kolmogorov-Smirnov and the means of the solutions were compared by Tukey′s honestly significant difference (HSD (P 0.05 discoloration compared with other media. Conclusions: Within the limitations of this study, it may be concluded that silorane-based composites are more resistant to discoloration than bis-GMA-based composites and coffee had the highest effect on composite discoloration compared to other media.

  6. Effect of various dentin disinfection protocols on the bond strength of resin modified glass ionomer restorative material.

    Science.gov (United States)

    Sekhar, Anand; Anil, Akansha; Thomas, Manuel S; Ginjupalli, Kishore

    2017-07-01

    Disinfection of dentin surface prior to any restorative therapy is important for the longevity of the treatment rendered. However, these dentin disinfection methods should itself not interfere with the adhesion of the restorative material. Therefore the aim of this study was to determine the effect of various dentin disinfection protocols on the shear bond strength (SBS) of resin modified glass ionomer cement (RMGIC). The occlusal surface of 40 extracted premolars were trimmed to obtain a flat dentinal surface and was randomly divided into four groups. CTRL was the control group; NaOCl was 1% sodium hypochlorite disinfection group; CHX was 2% chlorhexidine disinfection group; and PAD was the photo-activated disinfection group. Then a predetermined dimension of RMGIC was bonded to the pre-treated dentin surfaces. Following this, each sample was tested for SBS using universal testing machine at a crosshead speed of 0.5mm/min. Among the test groups, CHX showed the least reduction in SBS and NaOCl the highest reduction in SBS as compared to the control group. PAD on the other hand showed significantly lower SBS than CTRL and CHX groups, but the values were higher than the NaOCl group. Thus, it could be concluded from the present study that use of chlorhexidine based dentin disinfection does interfere with the adhesion of RMGIC. However, photo-activated disinfection should be done with caution. Moreover, sodium hypochlorite based disinfectants should be avoided prior to the use of RMGIC. Key words: Chlorhexidine, Dentin disinfection, Photo-activated disinfection, Resin modified glass ionomer cement, Shear bond strength, Sodium hypochlorite.

  7. Comparison of retention rates of fissure sealants using two flowable restorative materials and a conventional resin sealant: two-year follow-up.

    Science.gov (United States)

    Oba, Aylin Akbay; Sönmez, Işıl Şaroğlu; Ercan, Ertuğrul; Dülgergil, Türksel

    2012-01-01

    The purpose of this clinical study was to compare the retention rates of two flowable restorative systems (Admira Flow and Grandio Flow) with that of a conventional resin-based sealant (Fissurit F). The study was planned as a clinical trial with a split-mouth design. A total of 122 sealants (38 Admira Flow, 41 Grandio Flow, 43 Fissurit F) were randomly applied to completely erupted permanent molars in 35 patients aged 9-20 years and followed up for 24 months. Data were analyzed using Pearson's χ(2) and multiple comparison tests. At the end of the follow-up period, Fissurit F had higher retention rates (81.0%) than both Admira Flow (60.5%) and Grandio Flow (57.1%), with p 0.05). The two flowable composite resin materials used as fissure sealant were less retentive than the conventional resin sealant. Copyright © 2011 S. Karger AG, Basel.

  8. Mechanisms of Interactions of Energetic Electrons with Epoxy Resins

    Science.gov (United States)

    Gupta, A.; Coulter, D. R.; Tsay, F. D.; Moacanin, J.

    1982-01-01

    The mechanism of deactivation of energy of excitation in a resin system was investigated on optical excitation as well as excitation by high energy electrons. This mechanism involves formation of excited state complexes, known as exciplexes which have a considerable charge transfer character. This mechanism will be used to develop a degradation model for epoxy matrix materials deployed in a space environment.

  9. Radiopacity and microhardness changes and effect of X-ray operating voltage in resin-based materials before and after the expiration date

    Directory of Open Access Journals (Sweden)

    Tirapelli Camila

    2004-01-01

    Full Text Available This study observed alteration in the radiopacity and microhardness of expired resin-based materials compared to non-expired materials and the operating characteristics of the X-ray source used. Five 2 mm-thick cured specimens were prepared for each material: composite resins (P60®, Z100®, and a compomer (Dyract AP®. Radiopacity of the specimens was evaluated comparing the density of the resin-based material to an equivalent (mm density of a 99.5% pure aluminum step wedge using a transmission densitometer. Surface microhardness measurements were carried out using a calibrated Vickers indenter on three different points of the same surface. ANOVA and Tukey tests (pre-set alpha = 0.05 revealed that expired materials showed no significant change in radiopacity. One material (Filtek P60 demonstrated lower radiopacity with lower KVp. Change in microhardness wa s statistically significant for Z100: for this material, the microhardness after expiration was significantly lower than before the expiration date.

  10. Influence of mechanical and chemical degradation on surface gloss of resin composite materials

    NARCIS (Netherlands)

    Ardu, S.; Braut, V.; Uhac, I.; Benbachir, N.; Feilzer, A.J.; Krejci, I.

    2009-01-01

    Purpose: To determine the changes in surface gloss of different composite materials after simulation of mechanical and chemical aging mechanisms. Methods: 36 specimens were fabricated for each material and polished with 120-, 220-, 500-, 1200-, 2400- and 4000- grit SiC abrasive paper, respectively.

  11. Influence of different luting protocols on shear bond strength of computer aided design/computer aided manufacturing resin nanoceramic material to dentin

    OpenAIRE

    Claudio Poggio; Marco Pigozzo; Matteo Ceci; Andrea Scribante; Riccardo Beltrami; Marco Chiesa

    2016-01-01

    Background: The purpose of this study was to evaluate the influence of three different luting protocols on shear bond strength of computer aided design/computer aided manufacturing (CAD/CAM) resin nanoceramic (RNC) material to dentin. Materials and Methods: In this in vitro study, 30 disks were milled from RNC blocks (Lava Ultimate/3M ESPE) with CAD/CAM technology. The disks were subsequently cemented to the exposed dentin of 30 recently extracted bovine permanent mandibular incisors. The...

  12. Influence of Curing Units and Indirect Restorative Materials on the Hardness of Two Dual-curing Resin Cements Evaluated by the Nanoindentation Test.

    Science.gov (United States)

    Kuguimiya, Rosiane Noqueira; Rode, Kátia Martins; Carneiro, Paula Mendes Acatauassú; Aranha, Ana Cecilia Corrêa; Turbino, Miriam Lacalle

    2015-06-01

    To evaluate the hardness of a dual-curing self-adhesive resin cement (RelyX U200) and a conventional dual-curing resin cement (RelyX ARC) cured with different light curing units of different wavelengths (Elipar Freelight 2 LED [430 to 480 nm, conventional], Bluephase LED [380 to 515 nm, polywave], AccuCure 3000 Laser [488 nm]) by means of the nanoindentation test. Bovine incisors were cleaned and then sectioned at the cementoenamel junction to remove the crown. After embedding in acrylic, dentin surfaces of the specimens were exposed and ground flat to standardize the surfaces. To simulate clinically placing indirect restorations, ceramic (IPS e.maxPress/Ivoclar Vivadent) or indirect composite resin (SR Adoro/Ivoclar Vivadent) slabs were cemented on dentin surfaces. The specimens were sectioned longitudinally at low speed under constant irrigation and then polished. In the positive control group, the cement was light cured without the interposition of indirect restorative material; in the negative control group, after the indirect restorative material was cemented, no light curing was performed, allowing only chemical polymerization of the cement. All specimens were stored in distilled water at 37°C for 7 days. Nanoindentadion hardness of the cement layer was measured under a 100-mN load. Data were statistically analyzed using ANOVA and Tukey's test (p resin cements evaluated was negatively influenced by the interposition of an indirect restorative material; only the LEDs were able to maintain the same degree of cement polymerization when an indirect restorative material was used. The photoactivation step is required during the cementation of indirect restorations to ensure adequate polymerization of dual-curing resin cements.

  13. Implications of resin-based composite (RBC) restoration on cuspal deflection and microleakage score in molar teeth: Placement protocol and restorative material.

    Science.gov (United States)

    McHugh, Lauren E J; Politi, Ioanna; Al-Fodeh, Rami S; Fleming, Garry J P

    2017-09-01

    To assess the cuspal deflection of standardised large mesio-occluso-distal (MOD) cavities in third molar teeth restored using conventional resin-based composite (RBC) or their bulk fill restorative counterparts compared with the unbound condition using a twin channel deflection measuring gauge. Following thermocycling, the cervical microleakage of the restored teeth was assessed to determine marginal integrity. Standardised MOD cavities were prepared in forty-eight sound third molar teeth and randomly allocated to six groups. Restorations were placed in conjunction with (and without) a universal bonding system and resin restorative materials were irradiated with a light-emitting-diode light-curing-unit. The dependent variable was the restoration protocol, eight oblique increments for conventional RBCs or two horizontal increments for the bulk fill resin restoratives. The cumulative buccal and palatal cuspal deflections from a twin channel deflection measuring gauge were summed, the restored teeth thermally fatigued, immersed in 0.2% basic fuchsin dye for 24h, sectioned and examined for cervical microleakage score. The one-way analysis of variance (ANOVA) identified third molar teeth restored using conventional RBC materials had significantly higher mean total cuspal deflection values compared with bulk fill resin restorative restoration (all prestored teeth had significantly the lowest microleakage scores compared with Tetric EvoCeram Bulk Fill (bonded and non-bonded) teeth (all prestoratives behave in a similar manner when used to restore standardised MOD cavities in third molar teeth. It would appear that light irradiation of individual conventional RBCs or bulk fill resin restoratives may be problematic such that material selection is vital in the absence of clinical data. Copyright © 2017 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  14. Effect of asphaltene and resin oils on the viscosity of bituminous petroleum materials to be used as asphalt primers

    Directory of Open Access Journals (Sweden)

    Bencomo, M. R.

    2006-03-01

    Full Text Available The bituminous crude from the Machete, Venezuela, area, which has such a fluid consistency that it falls outside the normal scope of the A5TM D-5 (1 penetration test exceeding the 3D-mm ceiling specified in that standard and can be used as an asphalt primer: Like other asphalt products, these materials are -chemically speaking- a mix of numerous naphthenic, paraffinic and aromatic hydrocarbons and heterocyclic compounds containing sulphur, nitrogen, oxygen and so on. They have a dense and a malthene oil phase which, along with the natural hydrocarbons additives used in these products acts as a volatile fluidizer. The former is described as a mix of asphaltenes: complex high molecular weight substances that are insoluble in paraffinic hydrocarbons and soluble in aromatic compounds such as benzene. The malthene oil phase, in turn, consists in a mix of resins and hydrocarbons and together the two constitute a colloidal system. The experiments discussed in the present paper were conducted to determine the effect of the proportion of asphaltenes and resin oils on the viscosity of such bituminous crude emulsions/ with a view to their use as primers. These experiments were run in a Parr batch reactor in a nitrogen atmosphere using n-heptane as a solvent. The resins were separated after the asphaltenes precipitated from the samples and subsequently from the malthene fraction obtained. The results showed that the asphaltenes account for the structural characteristics and consistency of the medium and the resin oils for its cohesive properties/,the malthene oils act as solvents.Los crudos extrapesados procedentes del área Machete (Venezuela son materiales de consistencia blanda o fluida, por lo que se salen del campo en el que normalmente se aplica el ensayo de penetración a productos asfálticos según el método ASTM D-5 (1, cuyo límite máximo es 30 mm, y pueden ser utilizados como pinturas asfálticas de imprimación. Al igual que otros productos

  15. Drying time of tray adhesive for adequate tensile bond strength between polyvinylsiloxane impression and tray resin material.

    Science.gov (United States)

    Yi, Myong-Hee; Shim, Joon-Sung; Lee, Keun-Woo; Chung, Moon-Kyu

    2009-07-01

    Use of custom tray and tray adhesive is clinically recommended for elastomeric impression material. However there is not clear mention of drying time of tray adhesive in achieving appropriate bonding strength of tray material and impression material. This study is to investigate an appropriate drying time of tray adhesives by evaluating tensile bonding strength between two types of polyvinylsiloxane impression materials and resin tray, according to various drying time intervals of tray adhesives, and with different manufacturing company combination of impression material and tray adhesive. Adhesives used in this study were Silfix (Dentsply Caulk, Milford, Del, USA) and VPS Tray Adhesive (3M ESPE, Seefeld, Germany) and impression materials were Aquasil Ultra (monophase regular set, Dentsply Caulk, Milford, Del, USA) and Imprint II Garant (regular body, 3M ESPE, Seefeld, Germany). They were used combinations from the same manufacture and exchanged combinations of the two. The drying time was designed to air dry, 5 minutes, 10 minutes, 15 minutes, 20 minutes, and 25 minutes. Total 240 of test specimens were prepared by auto-polymerizing tray material (Instant Tray Mix, Lang, Wheeling, Il, USA) with 10 specimens in each group. The specimens were placed in the Universal Testing machine (Instron, model 3366, Instron Corp, University avenue, Nowood, MA, USA) to perform the tensile test (cross head speed 5 mm/min). The statistically efficient drying time was evaluated through ANOVA and Scheffe test. All the tests were performed at 95% confidence level. The results revealed that at least 10 minutes is needed for Silfix-Aquasil, and 15 minutes for VPS Tray Adhesive-Imprint II, to attain an appropriate tensile bonding strength. VPS Tray Adhesive-Imprint II had a superior tensile bonding strength when compared to Silfix-Aquasil over 15 minutes. Silfix-Aquasil had a superior bonding strength to VPS Tray Adhesive-Aquasil, and VPS Tray Adhesive-Imprint II had a superior tensile

  16. Penetration of a resin-based filling material into lateral root canals and quality of obturation by different techniques.

    Science.gov (United States)

    Michelotto, André Luiz da Costa; Moura-Netto, Cacio; Araki, Angela Toshie; Akisue, Eduardo; Sydney, Gilson Blitzkow

    2015-01-01

    The aim of this study was to evaluate the penetration of a resin/polyester polymer-based material (Resilon Real Seal; SybronEndo Corp., Orange, USA) into simulated lateral canals, and the quality of obturations by different techniques. A total of 30 standardized simulated canals were divided into three groups according to the technique of obturation used: MS (McSpadden), SB (SystemB/Obtura II), and LC (Lateral Condensation). To analyze the penetration of the filling material, the simulated canals were digitalized and the images were analyzed using the Leica QWIN Pro v2.3 software. The data of the middle and apical thirds were separately submitted to analysis of variance (ANOVA), followed by the Tukey's test for the comparison of the techniques. Results showed a significant difference (p test on interexaminer agreement and the nonparametric Kruskal-Wallis test indicated no significant difference between filling techniques. It was concluded that Resilon achieves greater levels of penetration when associated with thermoplastic obturation techniques.

  17. Polyimide Resins Resist Extreme Temperatures

    Science.gov (United States)

    2009-01-01

    Spacecraft and aerospace engines share a common threat: high temperature. The temperatures experienced during atmospheric reentry can reach over 2,000 F, and the temperatures in rocket engines can reach well over 5,000 F. To combat the high temperatures in aerospace applications, Dr. Ruth Pater of Langley Research Center developed RP-46, a polyimide resin capable of withstanding the most brutal temperatures. The composite material can push the service temperature to the limits of organic materials. Designed as an environmentally friendly alternative to other high-temperature resins, the RP-46 polyimide resin system was awarded a 1992 "R&D 100" award, named a "2001 NASA Technology of the Year," and later, due to its success as a spinoff technology, "2004 NASA Commercial Invention of the Year." The technology s commercial success also led to its winning the Langley s "Paul F. Holloway Technology Transfer Award" as well as "Richard T. Whitcom Aerospace Technology Transfer Award" both for 2004. RP-46 is relatively inexpensive and it can be readily processed for use as an adhesive, composite, resin molding, coating, foam, or film. Its composite materials can be used in temperatures ranging from minus 150 F to 2,300 F. No other organic materials are known to be capable of such wide range and extreme high-temperature applications. In addition to answering the call for environmentally conscious high-temperature materials, RP-46 provides a slew of additional advantages: It is extremely lightweight (less than half the weight of aluminum), chemical and moisture resistant, strong, and flexible. Pater also developed a similar technology, RP-50, using many of the same methods she used with RP-46, and very similar in composition to RP-46 in terms of its thermal capacity and chemical construction, but it has different applications, as this material is a coating as opposed to a buildable composite. A NASA license for use of this material outside of the Space Agency as well as

  18. A multi-stage curing technique toward improved dimensional infidelity of curve-shaped composites manufactured with vacuum assisted resin transfer molding

    Science.gov (United States)

    Teoh, Kai Jin

    The occurrence of dimensional infidelity during the curing process is detected as curved composites are being released from the mold after full consolidation. On the other hand, the lengthy cure cycle, thermal spiking and non-uniform consolidation in thick composite manufacturing are often strong deterrents to widespread industrial implementation. Therefore, a multi-stage curing technique is implemented and its outcome toward the spring-in phenomenon is investigated in this research. The composite processing technique of stage curing is useful for assessing the effects of thermal spiking, non-uniform consolidation and fiber wrinkling on mechanical integrity for thick composite structures. However, the prediction of spring-in behavior for a multi-stage curing process is still a relatively unexplored area in engineering research. As a result, a compatibility model based on the residual stress that builds up at each curing stage is performed in our study. Since the resin provides a lubricant effect between each curing stage, a partial slipping interface factor w is introduced to our numerical simulation model. The newly developed multi-stage curing model shows good agreement with the experimental results under Vacuum Assisted Resin Transfer Molding (VARTM) process.

  19. [Contact allergy to epoxy resins plastics based on materials collected by the Nofer Institute of Occupational Medicine].

    Science.gov (United States)

    Kieć-Swierczyńska, Marta; Krecisz, Beata

    2003-01-01

    Of the 5604 patients examined in 1984-2001 for suspected occupational dermatitis, 160 persons (2.8%) showed allergy to epoxy resins plastics. Allergy was more frequent in men (4.9%) than in women (1.2%); in 154 persons, allergy was of occupational etiology (in a group of 160 patients with allergy to epoxy resins, the following proportions were observed: bricklayers, platelayers--17.5%; fitters, turners, machinist millers--13.8%; plastics molders--13.1%; laminators--11.3%; electrical equipment assemblers--10.6%; painters--10.0%). Having compared the frequency of allergy to components of epoxy resins in the years 1984-1993 and 1994-2001, it was found that allergy to resin, reactive diluents and plasticizers was on increase, whereas allergy to amines and acid anhydrides hardeners was on decrease. In a group of 13 chemical compounds entering into the composition of epoxy resins, epoxy resin contributed to the largest number of positive patch tests (77.5% of epoxy-allergic persons). This was followed by triethylenetetramine (23.1%), ethylenediamine (13.1%), phthalic anhydride (8.1%), diethylenetetramine (6.9%) and phenylglycidylether (6.2%). In addition, three patients reacted to both epoxy resin and cycloaliphatic resin.

  20. Surface tridimensional topography analysis of materials and finishing procedures after resinous infiltration of subsurface bovine enamel lesions.

    Science.gov (United States)

    Mueller, Jan; Yang, Fan; Neumann, Konrad; Kielbassa, Andrej M

    2011-02-01

    To evaluate the effects of materials and finishing procedures on the surface roughness of infiltrated subsurface bovine enamel lesions. Eighty enamel specimens were prepared from 80 bovine incisors and partially varnished (control). The nonvarnished areas were demineralized (pH 4.95, 28 days) and etched with phosphoric acid gel (20%, 5 seconds). Specimens were randomly divided into two groups, which were each split into four subgroups (each n = 10): E1/E2 (Excite, Ivoclar Vivadent), F1/F2 (Fortify, Bisco), G1/G2 (Glaze and Bond, DMG), and I1/I2 (Icon, DMG). In group 1, resin materials were polymerized and polished using finishing strips by means of a polishing device; in group 2, excess material was removed with a rubber cup before polymerization (without polishing). The surface roughness (Sa) of control, demineralized, and treated surfaces were evaluated topometrically using a focus variation 3D scanning microscope. Demineralized surfaces were significantly rougher than sound enamel (P < .0005, t test). Etching increased Sa significantly to more than 450% of demineralization values (P < .0005). Surfaces of nonpolished infiltrated lesions were significantly rougher than demineralized enamel (P < .0005), while no significant differences could be found among infiltrated subgroups (P = .067), nor between polished and nonpolished groups (P = .359). Application of Glaze and Bond (G2) appeared to reduce Sa values of etched lesions (P < .0005), while with all other subgroups Sa values improved only marginally. Regarding surface roughness, the use of finishing strips after infiltration of subsurface lesions does not seem to be advantageous. Excess material should be removed before light curing, but surface quality of nonprocessed infiltrants seems to be perfectible.

  1. Initial study of new bio-based epoxy in carbon fiber reinforced composite panel manufactured by vacuum assisted resin transfer moulding

    Science.gov (United States)

    Hafiezal, M. R. M.; Abdan, Khalina; Azaman, M. D.; Abidin Z., Z.; Hanafee, Z. M.

    2017-09-01

    This research paper is about carbon fiber reinforced composite panels with novel bio-based epoxy derived from Malaysian crude Jatropha oil (Epoxidized Jatropha Oil) which is mixed with synthetic epoxy as matrix. Its manufacturability performances were then verified by tensile test, flexural test and burnt off test. Two composite panels (fiber carbon with 100 wt. % of synthetic epoxy and fiber carbon with 18 wt. % bio-epoxy blend with synthetic epoxy) were fabricated by vacuum assisted resin transfer moulding. Samples were cut according to respective ASTM dimensioning and were tested. It was found that the new composite panel performed well in manufacturability aspect with fiber volume fraction achieved was around 40 - 45%. Although its tensile and flexural performances are a bit lower but comparable, we could conclude that the novel bio-epoxy as matrix in fiber carbon reinforcement could be fabricated by using this process for further research.

  2. Raman spectral indicators of catalyst decoupling for transfer of CVD grown 2D materials

    DEFF Research Database (Denmark)

    Whelan, Patrick Rebsdorf; Jessen, Bjarke Sørensen; Wang, Ruizhi

    2017-01-01

    Through a combination of monitoring the Raman spectral characteristics of 2D materials grown on copper catalyst layers, and wafer scale automated detection of the fraction of transferred material, we reproducibly achieve transfers with over 97.5% monolayer hexagonal boron nitride and 99.7% monola...

  3. Novel nano-particles as fillers for an experimental resin-based restorative material.

    Science.gov (United States)

    Rüttermann, S; Wandrey, C; Raab, W H-M; Janda, R

    2008-11-01

    The purpose of this study is to compare the properties of two experimental materials, nano-material (Nano) and Microhybrid, and two trade products, Clearfil AP-X and Filtek Supreme XT. The flexural strength and modulus after 24h water storage and 5000 thermocycles, water sorption, solubility and X-ray opacity were determined according to ISO 4049. The volumetric behavior (DeltaV) after curing and after water storage was investigated with the Archimedes principle. ANOVA was calculated with p<0.05. Clearfil AP-X showed the highest flexural strength (154+/-14 MPa) and flexural modulus (11,600+/-550 MPa) prior to and after thermocycling (117+/-14 MPa and 13,000+/-300 MPa). The flexural strength of all materials decreased after thermocycling, but the flexural modulus decreased only for Filtek Supreme XT. After thermocycling, there were no significant differences in flexural strength and modulus between Filtek Supreme XT, Microhybrid and Nano. Clearfil AP-X had the lowest water sorption (22+/-1.1 microg mm(-3)) and Nano had the highest water sorption (82+/-2.6 microg mm(-3)) and solubility (27+/-2.9 microg mm(-3)) of all the materials. No significant differences occurred between the solubility of Clearfil AP-X, Filtek Supreme XT and Microhybrid. Microhybrid and Nano provided the highest X-ray opacity. Owing to the lower filler content, Nano showed higher shrinkage than the commercial materials. Nano had the highest expansion after water storage. After thermocycling, Nano performed as well as Filtek Supreme XT for flexural strength, even better for X-ray opacity but significantly worse for flexural modulus, water sorption and solubility. The performances of microhybrids were superior to those of the nano-materials.

  4. Physical Property Investigation of Contemporary Glass lonomer and Resin Modified Glass lonomer Restorative Materials

    Science.gov (United States)

    2016-05-24

    Innovation in Direct Restorative Materials. Adv Dent Res 2013;25:8-17. 4. Wilson AD, Kent BE. The glass-ionomer cement , a new translucent dental filling...material. J Appl Chem 1971;21:313. 5. Wilson AD, Batchelor RF. Dental silicate cements I. The chemistry of erosion. J Dent Res 1967;46:1078-85. 6...modlfied glass-ionomer dental cements . Biomater 2002;23: 3289-3295. 42. Young A, Sherpa G, Pearson B, Schottlander, Waters DN. Use of Raman Spectroscopy

  5. Clinical evaluation of a new art material: Nanoparticulated resin-modified glass ionomer cement

    Science.gov (United States)

    Konde, S.; Raj, S.; Jaiswal, D.

    2012-01-01

    Context: The success of atraumatic restorative treatment (ART) technique depends on the restorative material; hence, clinical studies with various materials are necessary. Aim: The aim of the present study was to clinically evaluate and compare the nanoionomer and high-viscosity glass ionomer using United States Public Health Services (USPHS) Modified Cvar/Ryge Criteria with ART approach. Materials and Methods: Two primary molars in 50 healthy children aged between 5 and 8 years were selected for the study. The teeth were treated with ART and divided into two groups. The group 1 teeth were restored with nanoionomer (Ketac Nano 100 3M ESPE) and group 2 with high-viscosity glass ionomer cement (HVGIC), (Fuji IX GC). Each restoration was evaluated using the USPHS Modified Cvar/Ryge Criteria at baseline and 6 months’ and 12 months’ time interval. Statistical analysis used: Chi-squared (χ2) test. Results: Nanoionomer was significantly better than HVGIC with respect to color match at baseline, 6 months, and 12 months (P0.05), but at 12 months, nanoionomer was statistically better than HVGIC (P0.05). Conclusion: The results indicate that nanoionomer can be a successful alternative restorative material for use with ART technique. PMID:24478966

  6. Microtensile Bond Strength of New Ceramic/Polymer Materials Repaired with Composite Resin

    Science.gov (United States)

    2015-06-30

    surface texture due to larger filler particles 4 and greater wear of the composite matrix material. The aforementioned study reported that...DVA, Corona , CA). Each bar specimen was loaded to failure, at a cross-head speed of 1mm/min on a universal testing machine (Model 5943, Instron

  7. Method of removing contaminants from plastic resins

    Energy Technology Data Exchange (ETDEWEB)

    Bohnert, George W. (Harrisonville, MO); Hand, Thomas E. (Lee' s Summit, MO); DeLaurentiis, Gary M. (Jamestown, CA)

    2008-11-18

    A method for removing contaminants from synthetic resin material containers using a first organic solvent system and a second carbon dioxide system. The organic solvent is utilized for removing the contaminants from the synthetic resin material and the carbon dioxide is used to separate any residual organic solvent from the synthetic resin material.

  8. Method of removing contaminants from plastic resins

    Energy Technology Data Exchange (ETDEWEB)

    Bohnert,George W. (Harrisonville, MO); Hand,Thomas E. (Lee' s Summit, MO); Delaurentiis,Gary M. (Jamestown, CA)

    2007-08-07

    A method for removing contaminants from synthetic resin material containers using a first organic solvent system and a second carbon dioxide system. The organic solvent is utilized for removing the contaminants from the synthetic resin material and the carbon dioxide is used to separate any residual organic solvent from the synthetic resin material.

  9. Method for removing contaminants from plastic resin

    Science.gov (United States)

    Bohnert, George W.; Hand, Thomas E.; DeLaurentiis, Gary M.

    2008-12-30

    A method for removing contaminants from synthetic resin material containers using a first organic solvent system and a second carbon dioxide system. The organic solvent is utilized for removing the contaminants from the synthetic resin material and the carbon dioxide is used to separate any residual organic solvent from the synthetic resin material.

  10. Green material composites from renewable resources: Polymorphic transitions and phase diagram of beeswax/rosin resin

    Energy Technology Data Exchange (ETDEWEB)

    Gaillard, Yves [Mines-ParisTech., CEMEF, UMR CNRS 7635, 1 rue Claude Daunesse 06904 Sophia Antipolis cedex (France); Mija, Alice [University of Nice-Sophia Antipolis, Thermokinetic Group, Laboratory of Chemistry of Organic and Metallic Materials C.M.O.M., 06108 Nice Cedex 2 (France); Burr, Alain; Darque-Ceretti, Evelyne; Felder, Eric [Mines-ParisTech., CEMEF, UMR CNRS 7635, 1 rue Claude Daunesse 06904 Sophia Antipolis cedex (France); Sbirrazzuoli, Nicolas, E-mail: sbirrazz@unice.fr [University of Nice-Sophia Antipolis, Thermokinetic Group, Laboratory of Chemistry of Organic and Metallic Materials C.M.O.M., 06108 Nice Cedex 2 (France)

    2011-07-10

    Highlights: {yields} Blends of Rosin and beeswax are studied by DSC, XRD, and optical microscopy. {yields} The first phase diagram beeswax/rosin is established. {yields} Polymorphic transitions are identified and appear to be highly related to rosin content. - Abstract: Rosin and beeswax are two complex natural materials presenting numerous applications in paints, adhesives, varnishes or inks. Melted, they are particularly interesting for their adhesion properties. This paper establishes the first phase diagram beeswax/rosin blends. A systematic approach using X-ray diffraction (XRD), differential scanning calorimetry (DSC) and polarised optical microscopy (POM) has been performed in order to describe the crystallographic structure and the thermal properties of two materials, beeswax and rosin, and their blends. Indeed, melting, softening and crystallisation temperatures, polymorphic transitions but also crystalline index has been investigated. The resulting phase diagram reveals a complex behaviour in terms of phase transformation and time-dependent phenomenon mainly representative of the complex composition of beeswax.

  11. Effects of air abrasion with alumina or glass beads on surface characteristics of CAD/CAM composite materials and the bond strength of resin cements

    Directory of Open Access Journals (Sweden)

    ARAO Nobuaki

    2015-12-01

    Full Text Available ABSTRACT Objective The study aimed to evaluate effects of air abrasion with alumina or glass beads on bond strengths of resin cements to CAD/CAM composite materials. Material and Methods CAD/CAM composite block materials [Cerasmart (CS and Block HC (BHC] were pretreated as follows: (a no treatment (None, (b application of a ceramic primer (CP, (c alumina-blasting at 0.2 MPa (AB, (d AB followed by CP (AB+CP, and (e glass-beads blasting at 0.4 MPa (GBB followed by CP (GBB+CP. The composite specimens were bonded to resin composite disks using resin cements [G-CEM Cerasmart (GCCS and ResiCem (RC]. The bond strengths after 24 h (TC 0 and after thermal cycling (TC 10,000 at 4–60°C were measured by shear tests. Three-way ANOVA and the Tukey compromise post hoc tests were used to analyze statistically significant differences between groups (α=0.05. Results For both CAD/CAM composite materials, the None group exhibited a significant decrease in bond strength after TC 10,000 (p0.05. The AB+CP group showed a significantly higher bond strength after TC 10,000 than did the AB group for RC (p<0.05, but not for GCCS. The GBB+CP group showed the highest bond strength for both thermal cyclings (p<0.05. Conclusions Air abrasion with glass beads was more effective in increasing bond durability between the resin cements and CAD/CAM composite materials than was using an alumina powder and a CP.

  12. Adhesion of resin materials to S2-glass unidirectional and E-glass multidirectional fiber reinforced composites: effect of polymerization sequence protocols.

    Science.gov (United States)

    Polacek, Petr; Pavelka, Vladimir; Ozcan, Mutlu

    2013-12-01

    To evaluate the effect of different polymerization sequences employed during application of bis-GMAbased particulate filler composites (PFC) or a flowable resin (FR) on fiber-reinforced composite (FRC). Unidirectional, pre-impregnated S2-glass fibers (Dentapreg) and multidirectional preimpregnated E-glass fibers (Dentapreg) (length: 40 mm; thickness: 0.5 mm) were obtained (N = 144, n = 12 per group) and embedded in translucent silicone material with the adhesion surface exposed. The resulting specimens were randomly divided into 12 groups for the following application sequences: a) FRC+PFC (photopolymerized in one step), b) FRC+FR (photopolymerized in one step), c) FRC+PFC (photopolymerized individually), d) FRC+FR (photopolymerized individually), e) FRC (photopolymerized)+intermediate adhesive resin and PFC (photopolymerized in one step), f) FRC (photopolymerized)+intermediate adhesive resin and FR (photopolymerized in one step). The sequences of unidirectional (groups a to f) were repeated for multidirectional (groups g to l) FRCs. PFCs were debonded from the FRC surfaces using the shear bond test in a universal testing machine (1 mm/min). On additional specimens from each FRC type, thermogravimetric analysis (TGA) was performed to characterize the fiber weight content (Wf) (N = 6, n = 3 per group). After debonding, all specimens were analyzed using SEM to categorize the failure modes. The data were statistically analyzed using 3-way ANOVA and Tukey's tests (α = 0.05). Significant effects of the FRC type (S2 or E-glass) (p resin type (PFC or FR) (p TGA revealed 55 ± 3 wt% fiber content for multidirectional and 60 ± 3 wt% for unidirectional FRCs tested. Multidirectional pre-impregnated E-glass fibers cannot be recommended in combination with the PFC and FR materials tested in this study. Application of an intermediate adhesive resin layer increases the adhesion of both PFC and FR to unidirectional FRC. FRC and FR can be polymerized in one step, but FRC and PFC

  13. Effect of gamma irradiation on fluoride release and antibacterial activity of resin dental materials

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Fabiola Galbiatti de; Fucio, Suzana Beatriz Portugal de; Correr-Sobrinho, Lourenco [Universidade Estadual de Campinas (UNICAMP), Piracicaba, SP (Brazil). Piracicaba Dental School. Dept. of Dental Materials; Pascon, Fernanda Miori; Kantovitz, Kamila Rosamilia; Puppin-Rontani, Regina Maria [Universidade Estadual de Campinas (UNICAMP), Piracicaba, SP (Brazil). Piracicaba Dental School. Dept. of Pedriatric Dentistry], e-mail: rmpuppin@fop.unicamp.br

    2009-07-01

    This study evaluated the effect of gamma irradiation on fluoride release and antibacterial activity of FluroShield (FS) and Clearfil Protect Bond (CPB). Four groups were formed: G1-FS + gamma; G2-FS without gamma; G3-CPB + gamma; G4-CPB without gamma. For fluoride release analysis, 12 disks of each material were prepared and covered with nail polish, except for one side (50.4 mm{sup 2} area). G1 and G3 were sterilized with a 14.5 KGy dose at 27 deg C for 24 h, while G2 and G4 (controls) were not sterilized and were maintained under the same time and temperature conditions. Fluoride release measurements were made in duplicate (n=6) by an ion specific electrode. The antibacterial activity of the CPB and FS against Streptococcus mutans after gamma sterilization was evaluated by the agar-disc diffusion method. The diameter of the zones of microbial growth inhibition was recorded after 48 h. Data were analyzed statistically by ANOVA and Tukey's test (alpha=5%). Gamma sterilization decreased the fluoride release of FS by approximately 50%, while CPB was not affected. There was no statistically significant difference (p>0.05) in the antibacterial effect of CPB between gamma and non-gamma sterilization groups. FS presented no antibacterial activity. Gamma irradiation decreased the fluoride release of FS, but did not affect the antibacterial activity of the studied materials. (author)

  14. Effect of gamma irradiation on fluoride release and antibacterial activity of resin dental materials

    International Nuclear Information System (INIS)

    Carvalho, Fabiola Galbiatti de; Fucio, Suzana Beatriz Portugal de; Correr-Sobrinho, Lourenco; Pascon, Fernanda Miori; Kantovitz, Kamila Rosamilia; Puppin-Rontani, Regina Maria

    2009-01-01

    This study evaluated the effect of gamma irradiation on fluoride release and antibacterial activity of FluroShield (FS) and Clearfil Protect Bond (CPB). Four groups were formed: G1-FS + gamma; G2-FS without gamma; G3-CPB + gamma; G4-CPB without gamma. For fluoride release analysis, 12 disks of each material were prepared and covered with nail polish, except for one side (50.4 mm 2 area). G1 and G3 were sterilized with a 14.5 KGy dose at 27 deg C for 24 h, while G2 and G4 (controls) were not sterilized and were maintained under the same time and temperature conditions. Fluoride release measurements were made in duplicate (n=6) by an ion specific electrode. The antibacterial activity of the CPB and FS against Streptococcus mutans after gamma sterilization was evaluated by the agar-disc diffusion method. The diameter of the zones of microbial growth inhibition was recorded after 48 h. Data were analyzed statistically by ANOVA and Tukey's test (alpha=5%). Gamma sterilization decreased the fluoride release of FS by approximately 50%, while CPB was not affected. There was no statistically significant difference (p>0.05) in the antibacterial effect of CPB between gamma and non-gamma sterilization groups. FS presented no antibacterial activity. Gamma irradiation decreased the fluoride release of FS, but did not affect the antibacterial activity of the studied materials. (author)

  15. Amalgam or composite resin? Factors influencing the choice of restorative material.

    Science.gov (United States)

    Correa, M B; Peres, M A; Peres, K G; Horta, B L; Barros, A D; Demarco, F F

    2012-09-01

    This study aimed to investigate the patient and tooth factors associated with selection of restorative material in direct posterior restorations in young adults from a population-based birth cohort. A representative sample (n=720) of all 5914 births occurring in Pelotas in 1982 were prospectively investigated, and posterior restorations were assessed in 2006, when the patients were 24 years old. Tooth-related variables (individual level) included restorative material (amalgam or composite), type of tooth, size of cavity, and estimated time in mouth. Data regarding demographic and socio-economic characteristics, oral health, and service utilization patterns during the life course were also assessed (contextual level). Logistic Regression Multilevel models showed that individuals who have accessed dental services by private insurance by age 15 [odds ratio (OR)=1.66 (0.93-2.95)] and who had a higher dental caries index at age 15 (high DMFT tertile) [OR 2.89 (1.59-5.27)] presented more amalgam restorations in the posterior teeth. From tooth-level variables, the frequency of amalgams decreases with increasing number of surfaces enrolled in the cavity preparation (pcomposite or amalgam in posterior direct restorations, showing that, independently of socioeconomic and demographic characteristics, type of payment of dental services and clinical factors are associated with this choice. Copyright © 2012. Published by Elsevier Ltd.

  16. Raman spectral indicators of catalyst decoupling for transfer of CVD grown 2D materials

    DEFF Research Database (Denmark)

    Whelan, Patrick Rebsdorf; Jessen, Bjarke Sørensen; Wang, Ruizhi

    2017-01-01

    Through a combination of monitoring the Raman spectral characteristics of 2D materials grown on copper catalyst layers, and wafer scale automated detection of the fraction of transferred material, we reproducibly achieve transfers with over 97.5% monolayer hexagonal boron nitride and 99.7% monola......Through a combination of monitoring the Raman spectral characteristics of 2D materials grown on copper catalyst layers, and wafer scale automated detection of the fraction of transferred material, we reproducibly achieve transfers with over 97.5% monolayer hexagonal boron nitride and 99.......7% monolayer graphene coverage, for up to 300 mm diameter wafers.We find a strong correlation between the transfer coverage obtained for graphene and the emergence of a lower wavenumber 2D peak component, with the concurrent disappearance of the higher wavenumber 2Dþ peak component during oxidation...

  17. Capture and transfer of pions in hydrogenous materials

    International Nuclear Information System (INIS)

    Armstrong, D.S.

    1990-05-01

    Pionic hydrogen is a short-lived exotic hydrogen isotope in which a negative pion replaces the atomic electron. The formation and subsequent interactions of pionic hydrogen are discussed, with emphasis on the process of pion transfer. Recent results using the pion charge-exchange reaction (π - , π 0 ) obtained at TRIUMF are reviewed. (Author) (35 refs., 3 tabs., 9 figs.)

  18. Radiation resistance of the carbon fiber reinforced composite material with PEEK as the matrix resin

    International Nuclear Information System (INIS)

    Sasuga, Tsuneo; Seguchi, Tadao; Sakai, Hideo; Nakakura, Toshiyuki; Masutani, Masahiro.

    1987-01-01

    In the fast breeder reactor etc. the structural materials are exposed to various environment, i.e., repeated high and low temperature, stress, etc. Irradiation effect (electron radiation) in the mechanical characteristic at low and high temperature has been studied in the PEEK-CF, polyarylether · ether · ketone - carbon fiber composite. Following are the results. (1) Radiation resistance of PEEK-CF is higher than that of PEEK-PES-CF, PEEK - polyethersulfone surface treated CF composite. In PEEK-PES-CF, PES is deteriorated by irradiation so the adhesive power lowers. (2) In the unirradiated PEEK-CF, its mechanical characteristic decreases beyond 140 deg C. With increase of the radiation dose, however, the characteristic rises. (3) Mechanical characteristic of PEEK-CF thus little drops by the heat treatment after the irradiation. (Mori, K.)

  19. Bio-active glass air-abrasion has the potential to remove resin composite restorative material selectively

    International Nuclear Information System (INIS)

    Milly, Hussam; Andiappan, Manoharan; Thompson, Ian; Banerjee, Avijit

    2014-01-01

    The aims of this study were to assess: (a) the chemistry, morphology and bioactivity of bio-active glass (BAG) air-abrasive powder, (b) the effect of three air-abrasion operating parameters: air pressure, powder flow rate (PFR) and the abrasive powder itself, on the selective removal of resin composite and (c) the required “time taken”. BAG abrasive particles were characterised using scanning electron microscopy-energy dispersive X-ray spectrometry (SEM-EDX) and Fourier-transform infrared spectroscopy (FTIR). Standardised resin composite restorations created within an enamel analogue block (Macor™) in vitro, were removed using air-abrasion undersimulated clinical conditions. 90 standardised cavities were scanned before and after resin composite removal using laser profilometry and the volume of the resulting 3D images calculated. Multilevel linear model was used to identify the significant factors affecting Macor™ removal. BAG powder removed resin composite more selectively than conventional air-abrasion alumina powder using the same operating parameters (p < 0.001) and the effect of altering the unit's operating parameters was significant (p < 0.001). In conclusion, BAG powder is more efficient than alumina in the selective removal of resin composite particularly under specific operating parameters, and therefore may be recommended clinically as a method of preserving sound enamel structure when repairing and removing defective resin composite restorations.

  20. Bio-active glass air-abrasion has the potential to remove resin composite restorative material selectively

    Energy Technology Data Exchange (ETDEWEB)

    Milly, Hussam [Biomaterials, Biomimetics and Biophotonics Research Group, Kings College London Dental Institute at Guy' s Hospital, King' s Health Partners, London (United Kingdom); Andiappan, Manoharan [Unit of Dental Public Health, Kings College London Dental Institute at Guy' s Hospital, King' s Health Partners, London (United Kingdom); Thompson, Ian [Biomaterials, Biomimetics and Biophotonics Research Group, Kings College London Dental Institute at Guy' s Hospital, King' s Health Partners, London (United Kingdom); Banerjee, Avijit, E-mail: avijit.banerjee@kcl.ac.uk [Biomaterials, Biomimetics and Biophotonics Research Group, Kings College London Dental Institute at Guy' s Hospital, King' s Health Partners, London (United Kingdom); Unit of Conservative Dentistry, King' s College London Dental Institute at Guy' s Hospital, King' s Health Partners, London (United Kingdom)

    2014-06-01

    The aims of this study were to assess: (a) the chemistry, morphology and bioactivity of bio-active glass (BAG) air-abrasive powder, (b) the effect of three air-abrasion operating parameters: air pressure, powder flow rate (PFR) and the abrasive powder itself, on the selective removal of resin composite and (c) the required “time taken”. BAG abrasive particles were characterised using scanning electron microscopy-energy dispersive X-ray spectrometry (SEM-EDX) and Fourier-transform infrared spectroscopy (FTIR). Standardised resin composite restorations created within an enamel analogue block (Macor™) in vitro, were removed using air-abrasion undersimulated clinical conditions. 90 standardised cavities were scanned before and after resin composite removal using laser profilometry and the volume of the resulting 3D images calculated. Multilevel linear model was used to identify the significant factors affecting Macor™ removal. BAG powder removed resin composite more selectively than conventional air-abrasion alumina powder using the same operating parameters (p < 0.001) and the effect of altering the unit's operating parameters was significant (p < 0.001). In conclusion, BAG powder is more efficient than alumina in the selective removal of resin composite particularly under specific operating parameters, and therefore may be recommended clinically as a method of preserving sound enamel structure when repairing and removing defective resin composite restorations.

  1. Preparation and characterization of hybrid materials of epoxy resin type bisphenol a with silicon and titanium oxides by sol-gel process

    International Nuclear Information System (INIS)

    Carrillo C, A.; Osuna A, J. G.

    2011-01-01

    Hybrid materials were synthesized from epoxy resins as a result bisphenol type A-silicon oxide and epoxy resin bisphenol type A-titanium oxide were obtained. The synthesis was done by sol-gel process using tetraethyl orthosilicate (Teos) and titanium isopropoxide (I Ti) as inorganic precursors. The molar ratio of bisphenol A to the inorganic precursors was the studied variable. The materials were characterized by thermal analysis, infrared spectroscopy, scanning electron microscopy and energy dispersive X-ray spectroscopy. The hybrid nature of the materials was demonstrated through thermal analysis and infrared spectroscopy. In both systems, as the amount of alkoxide increased, the bands described above were more defined. This behavior indicates the interactions between the resin and the alkoxides. Hybrids with Teos showed a smoother and homogeneous surface in its entirety, without irregularities. Hybrids with titanium isopropoxide had low roughness. Both Teos and I Ti hybrids showed a decrease on the atomic weight percentage of carbon due to a slight reduction of the organic part on the surface. (Author)

  2. Preparation and characterization of hybrid materials of epoxy resin type bisphenol a with silicon and titanium oxides by sol-gel process

    Energy Technology Data Exchange (ETDEWEB)

    Carrillo C, A.; Osuna A, J. G., E-mail: acc.carrillo@gmail.com [Universidad Autonoma de Coahuila, Facultad de Ciencias Quimicas, Blvd. Venustiano Carranza y Jose Cardenas Valdes, 25000 Saltillo, Coahuila (Mexico)

    2011-07-01

    Hybrid materials were synthesized from epoxy resins as a result bisphenol type A-silicon oxide and epoxy resin bisphenol type A-titanium oxide were obtained. The synthesis was done by sol-gel process using tetraethyl orthosilicate (Teos) and titanium isopropoxide (I Ti) as inorganic precursors. The molar ratio of bisphenol A to the inorganic precursors was the studied variable. The materials were characterized by thermal analysis, infrared spectroscopy, scanning electron microscopy and energy dispersive X-ray spectroscopy. The hybrid nature of the materials was demonstrated through thermal analysis and infrared spectroscopy. In both systems, as the amount of alkoxide increased, the bands described above were more defined. This behavior indicates the interactions between the resin and the alkoxides. Hybrids with Teos showed a smoother and homogeneous surface in its entirety, without irregularities. Hybrids with titanium isopropoxide had low roughness. Both Teos and I Ti hybrids showed a decrease on the atomic weight percentage of carbon due to a slight reduction of the organic part on the surface. (Author)

  3. Effect of LED-LCU light irradiance distribution on mechanical properties of resin based materials.

    Science.gov (United States)

    Magalhães Filho, T R; Weig, K M; Costa, M F; Werneck, M M; Barthem, R B; Costa Neto, C A

    2016-06-01

    The objective of this study is to analyze the light power distribution along the tip end of the light guide of three LED-LCUs (Light Curing Units) and to evaluate its effect on the mechanical properties of a polymer based dental composite. Firstly, the light power distribution over the whole area of LED-LCU light guide surface was analyzed by three methods: visual projection observation, spectral measurement and optical spectral analysis (OSA). The light power distribution and the total irradiance were different for the three LEDs used, but the wavelength was within the camphorquinone absorption spectrum. The use of a blank sheet was quite on hand to make a qualitative analysis of a beam, and it is costless. Secondly, specimens of a hybrid composite with approximately 8mm diameter and 2mm thickness were produced and polymerized by 20s exposition time to each LED-LCU. Thirdly, the elastic modulus (E) and hardness (HV) were measured throughout the irradiated area by instrumented micro-indentation test (IIT), allowing to correlate localized power and mechanical properties. Both E and HV showed to be very sensitive to local power and wavelength dependent, but they followed the beam power profile. It was also shown that the mechanical properties could be directly correlated to the curing process. Very steep differences in mechanical properties over very short distances may impair the material performance, since residual stresses can easily be built over it. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Preparation of CMC-modified melamine resin spherical nano-phase change energy storage materials.

    Science.gov (United States)

    Hu, Xiaofeng; Huang, Zhanhua; Zhang, Yanhua

    2014-01-30

    A novel carboxymethyl cellulose (CMC)-modified melamine-formaldehyde (MF) phase change capsule with excellent encapsulation was prepared by in situ polymerization. Effects of CMC on the properties of the capsules were studied by Fourier transformation infrared spectroscopy (FTIR), differential scanning calorimetry (DSC), scanning electronic microscopy (SEM), X-ray diffractometry (XRD), and thermogravimetric analysis (TGA). The results showed that the CMC-modified capsules had an average diameter of about 50nm and good uniformity. The phase change enthalpy of the capsules was increased and the cracking ratio decreased by incorporating a suitable amount of CMC. The optimum phase change enthalpy of the nanocapsules was 83.46J/g, and their paraffin content was 63.1%. The heat resistance of the capsule shells decreased after CMC modification. In addition, the nanocapsule cracking ratio of the nanocapsules was 11.0%, which is highly attractive for their application as nano phase change materials. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Development of dual-purpose metal cask for interim storage of spent nuclear fuel (3). A new type of durable neutron shielding resin

    International Nuclear Information System (INIS)

    Kamoshida, Mamoru; Nishi, Takashi; Iga, Kiminori; Shimizu, Masashi; Kashiwakura, Jun; Hayashi, Makoto

    2003-01-01

    Hitachi Ltd. has been developing a new neutron shielding resin for the dual-purpose metal cask. The newly developed resin is composed of a thermo setting epoxy and magnesium hydroxide. Highly durable resin can be obtained by combining base polymer having dense cross linkage and fire retardant with high dehydration temperature. Estimated weight loss of the resin during storage period is less than 1%. Fabrication process of shielding unit suitable for the new material is also developed. In the new process, a resin block constituted of cured resin and heat transfer fin is manufactured and fitted to the cask. This process was verified by fabricating about 200 resin blocks for real size mock-up of Hitachi's metal cask. (author)

  6. In vitro shear bond strength of Y-TZP ceramics to different core materials with the use of three primer/resin cement systems.

    Science.gov (United States)

    Al-Harbi, Fahad A; Ayad, Neveen M; Khan, Zahid A; Mahrous, Amr A; Morgano, Steven M

    2016-01-01

    Durability of the bond between different core materials and zirconia retainers is an important predictor of the success of a dental prosthesis. Nevertheless, because of its polycrystalline structure, zirconia cannot be etched and bonded to a conventional resin cement. The purpose of this in vitro study was to compare the effects of 3 metal primer/resin cement systems on the shear bond strength (SBS) of 3 core materials bonded to yttria-stabilized tetragonal zirconia polycrystalline (Y-TZP) ceramic retainers. Zirconia ceramic (Cercon) disks (5×3 mm) were airborne-particle abraded, rinsed, and air-dried. Disk-shaped core specimens (7×7 mm) that were prepared of composite resin, Ni-Cr, and zirconia were bonded to the zirconia ceramic disks by using one of 3 metal primer/cement systems: (Z-Prime Plus/BisCem, Zirconia Primer/Multilink Automix, or Clearfil Ceramic Primer/Clearfil SA). SBS was tested in a universal testing machine. Stereomicroscopy was used to evaluate the failure mode of debonded specimens. Data were analyzed using 2-way ANOVA and post hoc analysis using the Scheffe procedure (α=.05). Clearfil SA/Clearfil Ceramic Primer system with an Ni-Cr core yielded the highest SBS value (19.03 MPa), whereas the lowest SBS value was obtained when Multilink Automix/Zirconia Primer system was used with the zirconia core group (4.09 MPa). Differences in mean SBS values among the cement/primer groups were statistically significant, except for Clearfil SA and BisCem with both composite resin and zirconia cores. Differences in mean SBS values among the core subgroups were not statistically significant, except for zirconia core with BisCem, Multilink, and Clearfil SA. The predominant failure mode was adhesive, except for Clearfil SA and BisCem luting agents with composite resin cores, which displayed cohesive failure, and Multilink Automix with a composite resin, core as well as Clearfil SA with Ni-Cr cores, where the debonded specimens of each group displayed a mixed

  7. Fires involving radioactive materials : transference model; operative recommendations

    International Nuclear Information System (INIS)

    Rodriguez, C.E.; Puntarulo, L.J.; Canibano, J.A.

    1988-01-01

    In all aspects related to the nuclear activity, the occurrence of an explosion, fire or burst type accident, with or without victims, is directly related to the characteristics of the site. The present work analyses the different parameters involved, describing a transference model and recommendations for evaluation and control of the radiological risk for firemen. Special emphasis is placed on the measurement of the variables existing in this kind of operations

  8. Effect of bulk-fill base material on fracture strength of root-filled teeth restored with laminate resin composite restorations.

    Science.gov (United States)

    Taha, N A; Maghaireh, G A; Ghannam, A S; Palamara, J E

    2017-08-01

    To evaluate the effect of using a bulk-fill flowable base material on fracture strength and fracture patterns of root-filled maxillary premolars with MOD preparations restored with laminate restorations. Fifty extracted maxillary premolars were selected for the study. Standardized MOD cavities with endodontic treatment were prepared for all teeth, except for intact control. The teeth were divided randomly into five groups (n=10); (Group 1) sound teeth, (Group 2) unrestored teeth; (Group 3) MOD cavities with Vitrebond base and resin-based composite (Ceram. X One Universal); (Group 4) MOD cavities with 2mm GIC base (Fuji IX GP) and resin-based composite (Ceram. X One Universal) open laminate, (Group 5) MOD cavities were restored with 4mm of bulk-fill flowable base material (SDR) and resin-based composite (Ceram. X One Universal). All teeth were thermocycled and subjected to a 45° ramped oblique load in a universal testing machine. Fracture load and fracture patterns were recorded. Data were analyzed using one-way ANOVA and Dunnett's T3 test. Restoration in general increased the fracture strength compared to unrestored teeth. The fracture strength of group 5 (bulk-fill) was significantly higher than the fracture strength of the GIC laminate groups and not significantly different from the intact teeth (355±112N, P=0.118). The type of failure was unfavorable for most of the groups, with the majority being mixed failures. The use of a bulk-fill flowable base material significantly increased the fracture strength of extracted root-filled teeth with MOD cavities; however it did not improve fracture patterns to more favorable ones. Investigating restorative techniques that may improve the longevity of root-filled premolar teeth restored with direct resin restorations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Effects of Er:YAG laser and air abrasion on the microleakage of a resin-based fissure sealant material.

    Science.gov (United States)

    Sancakli, Hande Sar; Erdemir, Ugur; Yildiz, Esra

    2011-07-01

    The aim of the present study was to evaluate the effects of different surface pre-treatment techniques on the microleakage of a resin-based fissure sealant material. Thirty-five molars were divided into the following seven groups based on the surface pre-treatment technique used: (a) Erbium: Yttrium Aluminium Garnet (Er:YAG) laser (7 W); (b) Er:YAG laser (7 W)+acid etching (with 37% phosphoric acid); (c) Er:YAG laser (5.5 W); (d) Er:YAG laser (5.5 W)+acid etching; (e) air abrasion+acid etching; (f) air abrasion; and (g) conventional acid etching. The sealant was placed according to the manufacturers' instructions and light-cured for 20 sec. The sealed teeth were thermocycled for 10,000 cycles (5°-55°C), then immersed in 5% methylene blue for 24 h and sectioned mesiodistally. Each section was analyzed and photographed using a light microscope. Microleakage was assessed quantitatively by the degree of dye penetration and also qualitatively, scored on a three-point rating scale. Data were analyzed by one-way analysis of variance (ANOVA) and the Kruskal-Wallis test. The level of significance was set at p laser irradiation exhibited significantly higher microleakage than those conditioned with air abrasion followed by acid etching, and those conditioned with conventional acid etching (p Air abrasion followed by acid etching, as well as conventional acid etching, provided a sufficient seal, whereas laser irradiation alone or in combination with acid etching exhibited higher microleakage than did the other groups. Conventional acid etching remains the most effective and the simplest technique.

  10. Development of a novel resin-based dental material with dual biocidal modes and sustained release of Ag+ ions based on photocurable core-shell AgBr/cationic polymer nanocomposites.

    Science.gov (United States)

    Cao, Weiwei; Zhang, Yu; Wang, Xi; Chen, Yinyan; Li, Qiang; Xing, Xiaodong; Xiao, Yuhong; Peng, Xuefeng; Ye, Zhiwen

    2017-07-01

    Research on the incorporation of cutting-edge nano-antibacterial agent for designing dental materials with potent and long-lasting antibacterial property is demanding and provoking work. In this study, a novel resin-based dental material containing photocurable core-shell AgBr/cationic polymer nanocomposite (AgBr/BHPVP) was designed and developed. The shell of polymerizable cationic polymer not only provided non-releasing antibacterial capability for dental resins, but also had the potential to polymerize with other methacrylate monomers and prevented nanoparticles from aggregating in the resin matrix. As a result, incorporation of AgBr/BHPVP nanocomposites did not adversely affect the flexural strength and modulus but greatly increased the Vicker's hardness of resin disks. By continuing to release Ag + ions without the impact of anaerobic environment, resins containing AgBr/BHPVP nanoparticles are particularly suitable to combat anaerobic cariogenic bacteria. By reason of the combined bactericidal effect of the contact-killing cationic polymers and the releasing-killing Ag + ions, AgBr/BHPVP-containing resin disks had potent bactericidal activity against S. mutans. The long-lasting antibacterial activity was also achieved through the sustained release of Ag + ions due to the core-shell structure of the nanocomposites. The results of macrophage cytotoxicity showed that the cell viability of dental resins loading less than 1.0 wt% AgBr/BHPVP was close to that of neat resins. The AgBr/BHPVP-containing dental resin with dual bactericidal capability and long term antimicrobial effect is a promising material aimed at preventing second caries and prolonging the longevity of resin composite restorations.

  11. Characteristics of heat transfer during quenching high temperature material

    Energy Technology Data Exchange (ETDEWEB)

    Monde, Masaroni; Mitsutake, Yuhichi [Saga University (Japan). Inst. of Ocean Energy], e-mail: monde@me.saga-u.ac.jp

    2009-07-01

    This paper reviews characteristics of heat transfer during quenching high temperature body using liquid jet impingement. The temperature of body is initially kept higher than the Leidenfrost temperature. The flow pattern dramatically changes with a decrease in the surface temperature. At a moment of jet impingement, the liquid is randomly splashed away. After that, it seems to change a cone shape splashed flow, in which liquid is confirmed to be contact with the surface in an impinging zone. Finally, the liquid contact area where occurs rigorous boiling starts moving radially. Under such flow configuration, how surface temperature and heat flux change with time and homogenous nucleation for vapor generation are discussed. (author)

  12. Shear bond strength of a new self-adhering flowable composite resin for lithium disilicate-reinforced CAD/CAM ceramic material

    Science.gov (United States)

    Sancakli, Hande Sar; Sancakli, Erkan; Eren, Meltem Mert; Ozel, Sevda; Yucel, Taner; Yildiz, Esra

    2014-01-01

    PURPOSE The purpose of this study was to evaluate and compare the effects of different surface pretreatment techniques on the surface roughness and shear bond strength of a new self-adhering flowable composite resin for use with lithium disilicate-reinforced CAD/CAM ceramic material. MATERIALS AND METHODS A total of one hundred thirty lithium disilicate CAD/CAM ceramic plates with dimensions of 6 mm × 4 mm and 3 mm thick were prepared. Specimens were then assigned into five groups (n=26) as follows: untreated control, coating with 30 µm silica oxide particles (Cojet™ Sand), 9.6% hydrofluoric acid etching, Er:YAG laser irradiation, and grinding with a high-speed fine diamond bur. A self-adhering flowable composite resin (Vertise Flow) was applied onto the pre-treated ceramic plates using the Ultradent shear bond Teflon mold system. Surface roughness was measured by atomic force microscopy. Shear bond strength test were performed using a universal testing machine at a crosshead speed of 1 mm/min. Surface roughness data were analyzed by one-way ANOVA and the Tukey HSD tests. Shear bond strength test values were analyzed by Kruskal-Wallis and Mann-Whitney U tests at α=.05. RESULTS Hydrofluoric acid etching and grinding with high-speed fine diamond bur produced significantly higher surface roughness than the other pretreatment groups (Presin used as repair composite resin exhibited very low bond strength irrespective of the surface pretreatments used. PMID:25551002

  13. Repeated roll-to-roll transfer of two-dimensional materials by electrochemical delamination.

    Science.gov (United States)

    Hempel, M; Lu, A-Y; Hui, F; Kpulun, T; Lanza, M; Harris, G; Palacios, T; Kong, J

    2018-03-28

    Two-dimensional (2D) materials such as graphene (Gr), molybdenum disulfide and hexagonal boron nitride (hBN) hold great promise for low-cost and ubiquitous electronics for flexible displays, solar cells or smart sensors. To implement this vision, scalable production, transfer and patterning technologies of 2D materials are needed. Recently, roll-to-roll (R2R) processing, a technique that is widely used in industry and known to be cost-effective and scalable, was applied to continuously grow and transfer graphene. However, more work is needed to understand the possibilities and limitations of this technology to make R2R processing of 2D materials feasible. In this work, we fabricated a custom R2R transferring system that allows the accurate control of the process parameters. We employ continuous electrochemical delamination, known as "bubble transfer", to eliminate chemical etchant waste and enable the continuous transfer of 2D materials from metal foils. This also makes our transfer method a renewable and environmentally friendly process. We investigate the surface topology as well as the electrical parameters of roll-to-roll transferred graphene on polyethylene terephthalate (PET) coated with ethylene-vinyl acetate (EVA). Furthermore, we demonstrate for the first time the stacking of two layers of graphene or graphene on hBN by repeated lamination and delamination onto EVA/PET. These results are an important contribution to creating low-cost, large scale and flexible electronics based on 2D materials.

  14. Transfer tunnel transporter system for the Fuels and Materials Examination Facility

    International Nuclear Information System (INIS)

    Petty, J.A.; Miller, S.C.; Richards, J.T.

    1981-01-01

    The detail design is complete and fabrication is approximately 75% complete on the Transfer Tunnel Transporter System. This system provides material handling capability for large, bulky equipment between two hot cells in a new Breeder Reactor Program support facility, the Fuels and Materials Examination Facility. One hot cell has an air atmosphere, the other a high purity inert gas atmosphere which must be maintained during transfer operations. System design features, operational capabilities and remote recovery provisions are described

  15. Biokompatibilitas Gelas Ionomer Modifikasi Resin

    OpenAIRE

    Rotua Lestari M

    2008-01-01

    Saat ini banyak berkembang material baru dalam dunia kedokteran gigi diantaranya adalah Gelas ionomer modifikasi resin yang dikembangkan untuk mengatasi kekurangan-kekurangan dari gelas ionomer konvensional. Adanya penambahan monomer resin daIam bentuk 2-hydroxyethylmetacylate (HEMA) telah meningkatkan kekuatan dari bahan ini. Gelas ionomer modifikasi resin mempunyai sifat-sifat fisis dan mekanis yang lebih baik dibandingkan dengan gelas ionomer konvensional. Gelas ionomer modifikasi ...

  16. Light Transmission of Novel CAD/CAM Materials and Their Influence on the Degree of Conversion of a Dual-curing Resin Cement.

    Science.gov (United States)

    Egilmez, Ferhan; Ergun, Gulfem; Cekic-Nagas, Isil; Vallittu, Pekka K; Lassila, Lippo V J

    To evaluate the light transmission characteristics of different types, shades, and thicknesses of novel CAD/CAM materials and their effect on the degree of conversion (DC) of a dual-curing resin cement. Square specimens (12 × 12 mm2) of three CAD/CAM materials - GC Cerasmart, Lava Ultimate, Vita Enamic - of different thicknesses (1.00, 1.50, and 2.00 mm, n = 5 per thickness) were irradiated with an LED unit. The amount of transmitted light was quantified. Thereafter, the DC% of the dual-curing resin cement (RelyX Ultimate) was recorded after 15 min using Fourier transform infrared spectroscopy. Statistical analysis was performed using two-way ANOVA followed by the Tukey's HSD post-hoc test at a significance level of p light irradiation (p  0.05). Conversely, material thickness significantly affected light transmission (p light irradiation; p = 0.637 for DC). Linear regression analysis showed a correlation between delivered energy and DC% results of the Vita Enamic (R² = 0.4169, p light transmission in 2-mm-thick specimens of all CAD/CAM materials indicates that proper curing of the cement beneath CAD/CAM materials should be ensured.

  17. Technology transfer and international development: Materials and manufacturing technology

    Science.gov (United States)

    1982-01-01

    Policy oriented studies on technological development in several relatively advanced developing countries were conducted. Priority sectors defined in terms of technological sophistication, capital intensity, value added, and export potential were studied in Brazil, Venezuela, Israel, and Korea. The development of technological policy alternatives for the sponsoring country is assessed. Much emphasis is placed on understanding the dynamics of the sectors through structured interviews with a large sample of firms in the leading manufacturing and materials processing sectors.

  18. Synchronized fusion development considering physics, materials and heat transfer

    Science.gov (United States)

    Wong, C. P. C.; Liu, Y.; Duan, X. R.; Xu, M.; Li, Q.; Feng, K. M.; Zheng, G. Y.; Li, Z. X.; Wang, X. Y.; Li, B.; Zhang, G. S.

    2017-12-01

    Significant achievements have been made in the last 60 years in the development of fusion energy with the tokamak configuration. Based on the accumulated knowledge, the world is embarking on the construction and operation of ITER (International Thermonuclear Experimental Reactor) with a production of 500 MWf fusion power and the demonstration of physics Q  =  10. ITER will demonstrate D-T burn physics for a duration of a few hundred seconds to prepare for the next long-burn or steady state nuclear testing tokamak operating at much higher neutron fluence. With the evolution into a steady state nuclear device, such as the China Fusion Engineering Test Reactor (CFETR), it is necessary to examine the boundary conditions imposed by the combined development of tokamak physics, fusion materials and fusion technology for a reactor. The development of ferritic steel alloys as the structural material suitable for use at high neutron fluence leads to the use of helium as the most likely reactor coolant. This points to the fundamental technology limitation on the removal of chamber wall maximum heat flux at around 1 MW m-2 and an average heat flux of 0.1 MW m-2 for the next test reactor. Future reactor performance will then depend on the control of spatial and temporal edge heat flux peaking in order to increase the average heat flux to the chamber wall. With these severe material and technological limitations, system studies were used to scope out a few robust steady state synchronized fusion reactor (SFR) designs. As an example, a low fusion power design at 131.6 MWf, which can satisfy steady state design requirements, would have a major radius of 5.5 m and minor radius of 1.6 m. Such a design with even more advanced structural materials like W f/W composite could allow higher performance and provide a net electrical production of 62 MWe. These can be incorporated into the CFETR program.

  19. The effect of Er,Cr:YSGG laser application on the micropush-out bond strength of fiber posts to resin core material.

    Science.gov (United States)

    Kurtulmus-Yilmaz, Sevcan; Cengiz, Esra; Ozan, Oguz; Ramoglu, Serhat; Yilmaz, Hasan Guney

    2014-10-01

    The aim of this study was to compare the effects of erbium, chromium: yttrium, scandium, gallium, and garnet (Er,Cr:YSGG) laser application to different surface treatments on the micropush-out bond strengths between glass and quartz fiber posts and composite resin core material. Different types of lasers have been used as an alternative to airborne particle abrasion and other surface treatment methods to enhance the bond strength of dental materials. However, there is no study regarding the use of Er,Cr:YSGG laser as a surface treatment method for fiber posts in order to improve the bond strength. Ninety-six quartz and 96 glass fiber posts with a coronal diameter of 1.8 mm were randomly divided into eight groups according the surface treatments applied. Gr 1 (control, no surface treatment), Gr 2 (sandblasting with 50 μm Al2O3), Gr 3 (9 % hydrofluoric acid for 1 min), Gr 4 (24% H2O2 for 1 min), Gr 5 (CH2Cl2 for 1 min), Gr 6 (1 W), Gr 7 (1.5 W), and Gr 8 (2 W) Er,Cr:YSGG laser irradiation. The resin core material was applied to each group, and then 1 mm thick discs (n=12) were obtained for the micropush-out test. Data were statistically analyzed. For the quartz fiber post group, all surface treatments showed significantly higher micropush-out bond strengths than the control group (pmaterial. However, the hydroflouric acid group showed the lowest bond strength values. The type of post and surface treatment might affect the bond strength between fiber posts and resin core material; 1 W and 1.5 W Er,Cr:YSGG laser application improved adhesion at the post/core interface.

  20. Influence of halogen irradiance on short- and long-term wear resistance of resin-based composite materials.

    LENUS (Irish Health Repository)

    Bhamra, Gurcharn S

    2009-02-01

    The Oregon Health Science University (OHSU) four-chamber oral wear simulator was used to examine the impact of halogen irradiance on the short- and long-term wear behavior of four-methacrylate resin-based composites (RBCs). The hypothesis proposed was that exacerbated wear would occur following the long-term wear of RBCs irradiated under non-optimized irradiance conditions.

  1. Corrosion of heat exchanger materials under heat transfer conditions

    International Nuclear Information System (INIS)

    Tapping, R.L.; Lavoie, P.A.; Disney, D.J.

    1986-01-01

    Severe pitting has occurred in moderator heat exchangers tubed with Incoloy-800 in Pickering Nuclear Generating Station. The pitting originated on the cooling water side (outside) of the tubes and perforation occurred in less than two years. It was known from corrosion testing at Chalk River Laboratories that Incoloy-800 was not susceptible to pitting in Lake Ontario water under isothermal conditions. Corrosion testing with heat transfer across the tube wall was carried out, and it was noted that severe pitting could occur under deposits formed on the tubes in silty Lake Ontario water. Subsequent testing carried out in co-operation with Ontario Hydro Research Division, investigated the pitting resistance of other candidate tubing alloys: Incoloy-825, 904 L stainless steel, AL-6X, Inconel 625, 70:30 Cu:Ni, titanium, Sanicro-30 and Sanicro-28. Of these, only titanium and Sanicro-28 have not suffered some degree of pitting attack in silt-containing Lake Ontario water. In the absence of silt, and hence deposits, no pitting took place on any of the alloys tested. (author). 3 refs., 4 tabs., 6 figs

  2. Corrosion of heat exchanger materials under heat transfer conditions

    International Nuclear Information System (INIS)

    Tapping, R.L.; Lavoie, P.A.; Disney, D.J.

    1987-01-01

    Severe pitting has occurred in moderator heat exchangers tubed with Incoloy-800 in Pickering Nuclear Generating Station. The pitting originated on the cooling side (outside) of the tubes and perforation occurred in less than two years. It was known from corrosion testing at CRNL that Incoloy-800 was not susceptible to pitting in Lake Ontario water under isothermal conditions. Corrosion testing with heat transfer across the tube wall was carried out, and it was noted that severe pitting could occur under deposits formed on the tubes in silty Lake Ontario water. Subsequent testing, carried out in co-operation with Ontario Hydro Research Division, investigated the pitting resistance of other candidate tubing alloys: Incoloy-825, 904 L stainless steel, AL-6X, Inconel-625, 70:30 Cu:Ni, titanium, Sanicro-30 and Sanicro-28 1 . Of these, only titanium and Sanicro-28 have not suffered some degree of pitting attack in silt-containing Lake Ontario Water. In the absence of silt, and hence deposits, no pitting took place on any of the alloys tested

  3. Shear bond strength of a new self-adhering flowable composite resin for lithium disilicate-reinforced CAD/CAM ceramic material.

    Science.gov (United States)

    Erdemir, Ugur; Sancakli, Hande Sar; Sancakli, Erkan; Eren, Meltem Mert; Ozel, Sevda; Yucel, Taner; Yildiz, Esra

    2014-12-01

    The purpose of this study was to evaluate and compare the effects of different surface pretreatment techniques on the surface roughness and shear bond strength of a new self-adhering flowable composite resin for use with lithium disilicate-reinforced CAD/CAM ceramic material. A total of one hundred thirty lithium disilicate CAD/CAM ceramic plates with dimensions of 6 mm × 4 mm and 3 mm thick were prepared. Specimens were then assigned into five groups (n=26) as follows: untreated control, coating with 30 µm silica oxide particles (Cojet™ Sand), 9.6% hydrofluoric acid etching, Er:YAG laser irradiation, and grinding with a high-speed fine diamond bur. A self-adhering flowable composite resin (Vertise Flow) was applied onto the pre-treated ceramic plates using the Ultradent shear bond Teflon mold system. Surface roughness was measured by atomic force microscopy. Shear bond strength test were performed using a universal testing machine at a crosshead speed of 1 mm/min. Surface roughness data were analyzed by one-way ANOVA and the Tukey HSD tests. Shear bond strength test values were analyzed by Kruskal-Wallis and Mann-Whitney U tests at α=.05. Hydrofluoric acid etching and grinding with high-speed fine diamond bur produced significantly higher surface roughness than the other pretreatment groups (Presin used as repair composite resin exhibited very low bond strength irrespective of the surface pretreatments used.

  4. Device for transferring radioactive materials into a hot cell

    International Nuclear Information System (INIS)

    Engelmann, H.J.; Koller, J.

    1976-01-01

    The invention should ease the process of enclosing containers which contain radio-active material. A sliding tensioning arrangement is proposed, which can be clamped, and there is a container insert between this tensioning arrangement and the lock bar. The threee above-mentioned parts can be coupled up or uncoupled. The tensioning arrangement is preferably made as a pair of pliers surrounding the container. It is advantageous if the shielding container does not have to remain connected by a flange during the locking process. (UWI) [de

  5. A novel specimen-preparing method using epoxy resin as binding material for LIBS analysis of powder samples.

    Science.gov (United States)

    Shi, Linli; Lin, Qingyu; Duan, Yixiang

    2015-11-01

    In view of the inevitable preprocessing of powder samples for LIBS detection, epoxy resin glue was investigated for the first time as a binder of powder samples due to its superior property of improved performance in laser induced breakdown spectroscopy (LIBS) technique as a quantitative analytical tool. For comparative studies of the epoxy resin and traditional polyethylene (PE) pellets in soil, sample detection, the signal intensities of Fe (I) at 404.58 nm, Ca (I) at 443.57 nm, and Cr (I) at 453.52 nm, were studied and subsequently, the calibration curves for these elements were constructed using the standard samples with variable concentrations. The signal intensities of epoxy resin samples were, on average, about 2 times greater than those obtained with the traditional PE pellet samples. Meanwhile, the resin samples showed better R square values of 0.981, 0.985 and 0.979 for curves of Fe (I) 404.58 nm, Ca (I) 443.57 nm, and Cr (I) 453.52 nm, compared to the 0.974, 0.950 and 0.934, of the PE pellet samples. Furthermore, the former represented lower limits of detection (LOD) for Fe, Ca and Cr. These experimental results indicated that this proposed novel method based on epoxy resin can attach samples of properties of high homogeneity, cohesiveness, smoothness and hardness, which are conducive to system stability, testing accuracy and signal enhancement. This method can make LIBS more practical in powder sample analysis. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Effect of silver-supported materials on the mechanical and antibacterial properties of reinforced acrylic resin composites

    International Nuclear Information System (INIS)

    Han, Zhihui; Zhu, Bangshang; Chen, Rongrong; Huang, Zhuoli; Zhu, Cailian; Zhang, Xiuyin

    2015-01-01

    Highlights: • The novel Novaron-nano-ZrO 2 –ABW/PMMA composites was synthesized. • Nano-ZrO 2 and ABWs could increase the mechanical behavior of this composites. • Novaron had synergistic effect to improve the composites mechanical property and the 4 wt% was the optimal proportion. • Novaron could improve the antibacterial properties through their direct contact with the bacteria. • The composites did not have an adverse affect on cell viability. - Abstract: The aim of this study was to investigate the effect of silver-supported material (Novaron (N)) in acrylic resin (poly(methyl methacrylate) (PMMA)) composites, which reinforced with zirconium dioxide nanoparticles (nano-ZrO 2 ) and aluminum borate whiskers (ABWs), on the mechanical behavior, antibacterial properties and cytotoxicity. Silanized ABWs (4 wt%) and nano-ZrO 2 (2 wt%) were mixed with PMMA powder to obtain nano-ZrO 2 –ABW/PMMA matrices. Various amounts of Novaron particles were incorporated into the matrices and the pure PMMA to test the flexural strength. In addition, Streptococcus mutans (S. mutans) and Canidia albicans (C. albicans) biofilms on the specimen surface and in the culture medium were investigated for metabolic activity and colony-forming units (CFUs). Extracts taken in the cell culture medium of the specimens were used to evaluate cell viability. Results showed that the silanized nano-ZrO 2 and ABWs could improve the flexural strength of composites compared with the pure PMMA. Novaron itself had no mechanical function for composites while it had synergistic effect when it mixed with silanized nano-ZrO 2 and ABWs. And when 4 wt% (N-4) Novaron mixed in nano-ZrO 2 –ABW/PMMA composites, flexural strength achieved an increase of 44%, getting the maximum value. For the antibacterial properties, the values of MTT and CFUs of S. mutans and C. albicans biofilms on the composites surface were greatly reduced (p < 0.05) with the higher proportion of Novaron, and no significant

  7. In vitro evaluation of topical fluoride pH and their effect on surface hardness of composite resin-based restorative materials.

    Science.gov (United States)

    Mujeeb, Abdul; Mansuri, Samir; Hussain, Seema Abid; Ramaswamy, Kausar

    2014-03-01

    The aim of the study was to correlate the pH and fluoride ion uptake with surface hardness of composite resin based restorative materials after topical fluoride application. Forty disks of each of test materials Composite (Filtek Z350XT, 3M ESPE, St Paul, MN, USA), Resin modified glass ionomer (Vitremer) and Compomer (Dyract AP) were made and ten disks of each material were placed in different test solutions - 1.23% APF gel, Sodium fluoride mouth rinse, 0.9% neutral fluoride and distilled water (Control group). After 36 hours of immersion, specimens were subjected to microhardness testing machine for evaluation of surface hardness. The greater hardness deterioration for all materials resulted with 1.23% APF gel when compared to the control group. Composite (Filtek Z350XT, 3M ESPE, St Paul, MN, USA) showed 17.13 VHN (control group 59.11 VHN). Vitremer showed 9.71 VHN (control group 37.71 VHN). Compomer showed 19.22 VHN (control group 36.78 VHN). 1.23% ApF gel significantly decreased hardness of composite, Vitremer and Compomer. Hardness deterioration associated with sodium fluoride mouth rinse and 0.9% neutral fluoride was less compared to 1.23% ApF gel.

  8. Comparative evaluation of shear bond strength of three resin based dual-cure core build-up materials: An In-vitro study.

    Science.gov (United States)

    Jain, Gaurav; Narad, Aditi; Boruah, Lalit C; Rajkumar, Balakrishnan

    2015-01-01

    The in-vitro study compared the shear bond strength (SBS) of three recently introduced dual-cure resin based core build-up materials namely ParaCore, FluoroCore, and MultiCore. One hundred twenty extracted permanent human mandibular molar teeth were taken and sectioned horizontally beneath the dentinoenamel junction to expose the coronal dentin. The specimens obtained were divided into three main groups based on the materials used and then further divided into four sub-groups based on time interval with ten samples each. The dentin surface was treated with the respective adhesives of the groups and then bulk filled with core build-up materials. The attained samples were than subjected to shear loading in Instron Universal Testing Machine. The data were tabulated and statistically analyzed using analysis of variance (ANOVA), Tukey's HSD, and Levene's test. The mean SBS was highest in MultiCore at all time periods as compared to FluoroCore and ParaCore and was also higher at 48 h thermocycling in all three groups studied. MultiCore dual-cure resin based core build-up material showed the highest mean SBS as compared to FluoroCore and ParaCore. SBS was not negatively affected by thermocycling.

  9. In Vitro Solubility and Wear Rates of Silorane and Dimethacrylate Resin Based Composite Restorative Materials under Different pH Conditions

    Science.gov (United States)

    Soliman, Tarek A; Tubaigy, Khalid M; Raffat, Eman M; Al-Agha, Ebaa I

    2015-01-01

    Background: The purpose of this study was to evaluate the effect of different pH solutions on the solubility and wear resistance of Silorane and dimethacrylate resin based composite restorative materials. Materials and Methods: Two different resin based restorative materials (Filtek Silorane P90 and hybrid composite Z100) were tested. Different pH solutions (2.5 and 5) also were used. A total of 60 samples of each type of selected composite were prepared. Specimens were immersed in each type of pH solutions (2.5 and 5) and distilled water as a control group for 24 h then the specimens was subjected to the required mechanical tests. Results: Significant statistical differences were observed regarding water solubility and wear values in different pH solutions. Filtek Silorane presented the smallest values of water solubility and wear values. Conclusion: Under tested experimental conditions, the pH solutions used in this study showed pronounced effect on water solubility and wear values of both two restorative materials. Finally, within the limitation of this study we recommended to use Filtek Silorane (P90) instead of hybrid (Z100) due to its low solubility values under different pH solutions. PMID:26225097

  10. The influence of resin flexural modulus on the magnitude of ceramic strengthening.

    LENUS (Irish Health Repository)

    Fleming, Garry J P

    2012-07-01

    The aim was to determine the magnitude of ceramic resin-strengthening with resin-based materials with varying flexural moduli using a regression technique to assess the theoretical strengthening at a \\'zero\\' resin-coating thickness. The hypothesis tested was that experimentally, increasing resin flexural modulus results in increased resin-strengthening observed at a theoretical \\'zero\\' resin-coating thickness.

  11. Surface hardness evaluation of different composite resin materials: influence of sports and energy drinks immersion after a short-term period

    Directory of Open Access Journals (Sweden)

    Ugur Erdemir

    2013-04-01

    Full Text Available Objectives: This study evaluated the effect of sports and energy drinks on the surface hardness of different composite resin restorative materials over a 1-month period. Material and Methods: A total of 168 specimens: Compoglass F, Filtek Z250, Filtek Supreme, and Premise were prepared using a customized cylindrical metal mould and they were divided into six groups (N=42; n=7 per group. For the control groups, the specimens were stored in distilled water for 24 hours at 37°C and the water was renewed daily. For the experimental groups, the specimens were immersed in 5 mL of one of the following test solutions: Powerade, Gatorade, X-IR, Burn, and Red Bull, for two minutes daily for up to a 1-month test period and all the solutions were refreshed daily. Surface hardness was measured using a Vickers hardness measuring instrument at baseline, after 1-week and 1-month. Data were statistically analyzed using Multivariate repeated measure ANOVA and Bonferroni's multiple comparison tests (α=0.05. Results: Multivariate repeated measures ANOVA revealed that there were statistically significant differences in the hardness of the restorative materials in different immersion times (p<0.001 in different solutions (p<0.001. The effect of different solutions on the surface hardness values of the restorative materials was tested using Bonferroni's multiple comparison tests, and it was observed that specimens stored in distilled water demonstrated statistically significant lower mean surface hardness reductions when compared to the specimens immersed in sports and energy drinks after a 1-month evaluation period (p<0.001. The compomer was the most affected by an acidic environment, whereas the composite resin materials were the least affected materials. Conclusions: The effect of sports and energy drinks on the surface hardness of a restorative material depends on the duration of exposure time, and the composition of the material.

  12. A new technology for separation and recovery of materials from waste printed circuit boards by dissolving bromine epoxy resins using ionic liquid

    International Nuclear Information System (INIS)

    Zhu, P.; Chen, Y.; Wang, L.Y.; Qian, G.Y.; Zhou, M.; Zhou, J.

    2012-01-01

    Highlights: ► WPCBs were heated in [EMIM + ][BF 4 − ] for recovering solider at 240 °C. ► The bromine epoxy resins in WPCBs were all dissolved in [EMIM + ][BF 4 − ] at 260 °C. ► Used [EMIM + ][BF 4 − ] is treated by water to obtain regeneration. - Abstract: Recovery of valuable materials from waste printed circuit boards (WPCBs) is quite difficult because WPCBs is a heterogeneous mixture of polymer materials, glass fibers, and metals. In this study, WPCBs was treated using ionic liquid (1-ethyl-3-methylimizadolium tetrafluoroborate [EMIM + ][BF 4 − ]). Experimental results showed that the separation of the solders went to completion, and electronic components (ECs) were removed in WPCBs when [EMIM + ][BF 4 − ] solution containing WPCBs was heated to 240 °C. Meanwhile, metallographic observations verified that the WPCBs had an initial delamination. When the temperature increased to 260 °C, the separation of the WPCBs went to completion, and coppers and glass fibers were obtained. The used [EMIM + ][BF 4 − ] was treated by water to generate a solid–liquid suspension, which was separated completely to obtain solid residues by filtration. Thermal analyses combined with infrared ray spectra (IR) observed that the solid residues were bromine epoxy resins. NMR (nuclear magnetic resonance) showed that hydrogen bond played an important role for [EMIM + ][BF 4 − ] dissolving bromine epoxy resins. This clean and non-polluting technology offers a new way to recycle valuable materials from WPCBs and prevent environmental pollution from WPCBs effectively.

  13. The influence of surface treatment on mass transfer between air and building material

    DEFF Research Database (Denmark)

    Kwiatkowski, Jerzy; Rode, Carsten; Hansen, Kurt Kielsgaard

    2008-01-01

    The processes of mass transfer between air and building structure and in the material influence not only the conditions within the material but also inside the connected air spaces. The material which absorbs and desorbs water vapour can be used to moderate the amplitude of indoor relative humidity...... and therefore to participate in the improvement of the indoor air quality and energy saving. Many parameters influence water vapour exchange between indoor air and building material. The aim of this work is to present the change of mass transfer under different climatic and material conditions. The measurements...... for the experiments: gypsum board and calcium silicate. The wallpaper and paint were used as finishing materials. Impact of the following parameters for changes of RH was studied: coating, temperature and air movement. The measurements showed that acryl paint (diffusion open) can significantly decrease mass uptake...

  14. A new technology for separation and recovery of materials from waste printed circuit boards by dissolving bromine epoxy resins using ionic liquid.

    Science.gov (United States)

    Zhu, P; Chen, Y; Wang, L Y; Qian, G Y; Zhou, M; Zhou, J

    2012-11-15

    Recovery of valuable materials from waste printed circuit boards (WPCBs) is quite difficult because WPCBs is a heterogeneous mixture of polymer materials, glass fibers, and metals. In this study, WPCBs was treated using ionic liquid (1-ethyl-3-methylimizadolium tetrafluoroborate [EMIM+][BF4-]). Experimental results showed that the separation of the solders went to completion, and electronic components (ECs) were removed in WPCBs when [EMIM+][BF4-] solution containing WPCBs was heated to 240 °C. Meanwhile, metallographic observations verified that the WPCBs had an initial delamination. When the temperature increased to 260 °C, the separation of the WPCBs went to completion, and coppers and glass fibers were obtained. The used [EMIM+][BF4-] was treated by water to generate a solid-liquid suspension, which was separated completely to obtain solid residues by filtration. Thermal analyses combined with infrared ray spectra (IR) observed that the solid residues were bromine epoxy resins. NMR (nuclear magnetic resonance) showed that hydrogen bond played an important role for [EMIM+][BF4-] dissolving bromine epoxy resins. This clean and non-polluting technology offers a new way to recycle valuable materials from WPCBs and prevent environmental pollution from WPCBs effectively. Crown Copyright © 2012. Published by Elsevier B.V. All rights reserved.

  15. Non-local spatial frequency response of photopolymer materials containing chain transfer agents: I. Theoretical modelling

    International Nuclear Information System (INIS)

    Guo, Jinxin; Gleeson, Michael R; Liu, Shui; Sheridan, John T

    2011-01-01

    The non-local photopolymerization driven diffusion (NPDD) model predicts that a reduction in the non-local response length within a photopolymer material will improve its high spatial frequency response. The introduction of a chain transfer agent reduces the average molecular weight of polymer chains formed during free radical polymerization. Therefore a chain transfer agent (CTA) provides a practical method to reduce the non-local response length. An extended NPDD model is presented, which includes the chain transfer reaction and most major photochemical processes. The addition of a chain transfer agent into an acrylamide/polyvinyl alcohol photopolymer material is simulated and the predictions of the model are examined. The predictions of the model are experimentally examined in part II of this paper

  16. Simultaneous Heat and Mass Transfer Model for Convective Drying of Building Material

    Science.gov (United States)

    Upadhyay, Ashwani; Chandramohan, V. P.

    2018-04-01

    A mathematical model of simultaneous heat and moisture transfer is developed for convective drying of building material. A rectangular brick is considered for sample object. Finite-difference method with semi-implicit scheme is used for solving the transient governing heat and mass transfer equation. Convective boundary condition is used, as the product is exposed in hot air. The heat and mass transfer equations are coupled through diffusion coefficient which is assumed as the function of temperature of the product. Set of algebraic equations are generated through space and time discretization. The discretized algebraic equations are solved by Gauss-Siedel method via iteration. Grid and time independent studies are performed for finding the optimum number of nodal points and time steps respectively. A MATLAB computer code is developed to solve the heat and mass transfer equations simultaneously. Transient heat and mass transfer simulations are performed to find the temperature and moisture distribution inside the brick.

  17. Development of Novel Electrode Materials for the Electrocatalysis of Oxygen-Transfer and Hydrogen-Transfer Reactions

    Energy Technology Data Exchange (ETDEWEB)

    Simpson, Brett Kimball [Iowa State Univ., Ames, IA (United States)

    2002-01-01

    Throughout this thesis, the fundamental aspects involved in the electrocatalysis of anodic O-transfer reactions and cathodic H-transfer reactions have been studied. The investigation into anodic O-transfer reactions at undoped and Fe(III)[doped MnO2 films] revealed that MnO2 film electrodes prepared by a cycling voltammetry deposition show improved response for DMSO oxidation at the film electrodes vs. the Au substrate. Doping of the MnO2 films with Fe(III) further enhanced electrode activity. Reasons for this increase are believed to involve the adsorption of DMSO by the Fe(III) sites. The investigation into anodic O-transfer reactions at undoped and Fe(III)-doped RuO2 films showed that the Fe(III)-doped RuO2-film electrodes are applicable for anodic detection of sulfur compounds. The Fe(III) sites in the Fe-RuO2 films are speculated to act as adsorption sites for the sulfur species while the Ru(IV) sites function for anodic discharge of H2O to generate the adsorbed OH species. The investigation into cathodic H-transfer reactions, specifically nitrate reduction, at various pure metals and their alloys demonstrated that the incorporation of metals into alloy materials can create a material that exhibits bifunctional properties for the various steps involved in the overall nitrate reduction reaction. The Sb10Sn20Ti70, Cu63Ni37 and Cu25Ni75 alloy electrodes exhibited improved activity for nitrate reduction as compared to their pure component metals. The Cu63Ni37 alloy displayed the highest activity for nitrate reduction. The final investigation was a detailed study of the electrocatalytic activity of cathodic H-transfer reactions (nitrate reduction) at various compositions of Cu-Ni alloy electrodes. Voltammetric response for NO3- at the Cu-Ni alloy electrode is superior to

  18. Polyoxometalate active charge-transfer material for mediated redox flow battery

    Science.gov (United States)

    Anderson, Travis Mark; Hudak, Nicholas; Staiger, Chad; Pratt, Harry

    2017-01-17

    Redox flow batteries including a half-cell electrode chamber coupled to a current collecting electrode are disclosed herein. In a general embodiment, a separator is coupled to the half-cell electrode chamber. The half-cell electrode chamber comprises a first redox-active mediator and a second redox-active mediator. The first redox-active mediator and the second redox-active mediator are circulated through the half-cell electrode chamber into an external container. The container includes an active charge-transfer material. The active charge-transfer material has a redox potential between a redox potential of the first redox-active mediator and a redox potential of the second redox-active mediator. The active charge-transfer material is a polyoxometalate or derivative thereof. The redox flow battery may be particularly useful in energy storage solutions for renewable energy sources and for providing sustained power to an electrical grid.

  19. Polymerization shrinkage stress of resin-based dental materials: A systematic review and meta-analyses of technique protocol and photo-activation strategies.

    Science.gov (United States)

    Münchow, Eliseu Aldrighi; Meereis, Carine Tais Welter; de Oliveira da Rosa, Wellington Luiz; da Silva, Adriana Fernandes; Piva, Evandro

    2018-03-08

    A systematic review was conducted to determine whether there were any alternative technique or additional step strategies available to reduce and control polymerization shrinkage stress development in dental resin-based restorative materials. This report followed the PRISMA Statement. A total of 36 studies were included in this review. Two reviewers performed a literature search up to December 2016, without restriction of the year of publication, in seven databases: PubMed, Web of Science, Scopus, SciELO, LILACS, IBECS, and BBO. Only in vitro studies that evaluated polymerization shrinkage stress by direct testing were included. Pilot studies, reviews and in vitro studies that evaluated polymerization shrinkage stress by indirect methods (e.g., microleakage or cuspal deflection measurements), finite elemental analysis or mathematical models were excluded. Of the 6.113 eligible articles, 36 studies were included in the qualitative analysis, and the meta-analysis was performed with 25 studies. A global comparison was performed with random-effects models (α = 0.05). The strategies were subdivided as follows: the use of an alternative technique protocol of placing the material inside the tooth cavity; the modification of the irradiation intensity or total energy delivered to the material; the use of an alternative light-curing source; or the use of an alternative photo-activation mode. All alternative strategies showed statistically significant differences when compared with their respective controls (p material by means of an alternative technique protocol or by modifying the irradiant intensity or total energy delivered to the material during photo-activation. Moreover, the use of an alternative photo-activation mode (intermittent light, exponential, soft-start or pulse delay modes) was shown to be an effective strategy for reducing and controlling stress development in resin-based dental materials. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Effect of ceramic material and resin cement systems on the color stability of laminate veneers after accelerated aging.

    Science.gov (United States)

    Lee, Seong-Min; Choi, Yu-Sung

    2018-01-05

    Laminate veneers are susceptible to color change during clinical service. Studies that compare the effects of different ceramic and resin cement systems on color stability are lacking. The purpose of this in vitro study was to evaluate the color stability of laminate veneers after accelerated aging using different ceramic and resin cement systems. Ceramic specimens (N=168; shade A1; thickness, 0.50 ±0.05 mm; diameter, 10.00 ±0.10 mm) were prepared using nanofluorapatite and lithium disilicate (high translucency [HT] to low translucency [LT]) ceramics. Light-polymerizing (LP) cements were classified by brightness (high or low). Dual-polymerizing cements were classified by composition (base-only [DB] or base-catalyst [DC]) for comparison of color stability on the basis of polymerization type. DB cement was light-polymerizing, whereas DC cement was dual-polymerizing. They were further classified by shade (transparent, white, or yellow [n=7, each]). Color difference (ΔE) values were obtained by spectrophotometric quantification of L* (lightness), a* (green-red), and b* (blue-yellow) values before and after aging. The Kruskal-Wallis, Mann-Whitney U, Wilcoxon signed rank, and Bonferroni post hoc tests were used for statistical analysis. After specimens were subjected to accelerated aging, HT ceramic specimens luted with yellow-shade DC cement exhibited the greatest color change (ΔE=2.11), whereas HT and LT ceramic specimens luted with low-brightness LP cement exhibited the least color change (ΔE=1.37). In HT ceramic specimens, which exhibited the greatest color change of the 3 ceramic types, transparent shade cement exhibited significantly lower ΔE values than the other shades with DB (Pceramics. The ΔE values of DB cement were not always lower than those of DC cement. For all specimens, the aging of laminate veneers decreased the L* values and increased the a* and b* values. Ceramic and resin-cement systems affected the color stability of laminate veneers

  1. A role for research ethics committees in exchanges of human biospecimens through material transfer agreements.

    Science.gov (United States)

    Chalmers, Donald; Nicol, Dianne; Nicolás, Pilar; Zeps, Nikolajs

    2014-09-01

    International transfers of human biological material (biospecimens) and data are increasing, and commentators are starting to raise concerns about how donor wishes are protected in such circumstances. These exchanges are generally made under contractual material transfer agreements (MTAs). This paper asks what role, if any, should research ethics committees (RECs) play in ensuring legal and ethical conduct in such exchanges. It is recommended that RECs should play a more active role in the future development of best practice MTAs involving exchange of biospecimens and data and in monitoring compliance.

  2. Evaluation of the color durability of acrylic resin veneer materials after immersion in common beverages at different time intervals: A spectrophotometric study

    Directory of Open Access Journals (Sweden)

    Shivani Kohli

    2015-06-01

    Full Text Available Background: Proper function, esthetics, and cost are the prime factors to be considered while selecting bridge veneering materials. The purpose of the study is to evaluate color durability of acrylic veneer materials after immersion in common beverages at different time intervals. Methods: Spectrophotometer was used for taking color measurements based on the transmission of light through the specimens made of the selected materials which were Tooth moulding powder (DPI and Acrylux (Ruthinium. Thirty specimens of standardized dimensions were prepared from each material. The specimens were divided into three groups of 10 each. One group of each material was immersed in tea (TajMahal and another group of each material in cola (Pepsi as the staining solutions. The remaining group of 10 from each material served as control and was stored in distilled water. Color measurements were obtained pre-immersion, and after 1, 15, and 30 days of immersion. Results: Tooth moulding powder displayed better color durability than Acrylux over the 1 month immersion period in both staining solutions. Tea resulted in more discoloration compared to cola (Pepsi. Conclusion: The difference in the color durability of Acrylux and Tooth moulding powder may be attributed to the differences in the composition of tested resin veneering materials, i.e. their polar properties, which contribute to the absorption of staining solution, and the different brands and the strengths of the solutions.

  3. Investigation of porous graphitic carbon for triterpenoids and natural resinous materials analysis by high performance liquid chromatography hyphenated to mass spectrometry.

    Science.gov (United States)

    Rhourri-Frih, B; Chaimbault, P; Dequeral, D; André, P; Lafosse, M

    2012-06-01

    Natural resinous materials are mainly composed of pentacyclic triterpenes which exhibit a large number of interesting medicinal activities. However, the presence of numerous isomers within the active substances makes their screening by HPLC very challenging. Porous graphitic carbon was investigated as stationary phase to achieve triterpenes isomers separation. The influence of various parameters (temperature, formic acid concentration and mobile phase composition) on the retention was considered. A usual decrease of the retention of triterpenes was observed with the increase of the temperature. Therefore, separation in resinous materials was performed at 25°C. Acetonitrile-isopropanol mixture was chosen as mobile phase in gradient elution and leads to the best compromise between efficiency and high resolution. The lack of chromophore groups in the pentacyclic triterpenes structures required the use of mass spectrometry detection. Moreover, atmospheric pressure photo-ionisation mass spectrometry prevents compounds fragmentation which was helpful for spectra interpretation and compounds identification. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Potentiometric Sensors for Pr(III Based on N-N᾽o-Phenylene-bis(salicylideneimine Using Epoxy Resin and PVC as Binding Materials

    Directory of Open Access Journals (Sweden)

    K. Sharma Harish

    2011-01-01

    Full Text Available Praseodymium(III ion selective electrodes have been prepared using N-N᾽o-phenylene-bis(salicylideneimine as a suitable electro-active material. Several membranes comprising of varying compositions of electro-active material with epoxy resin and polyvinylchloride (PVC as binding materials were prepared. However the one with composition 50% Schiff᾽s base and 50% binder was found to exhibit best performance. The sensor with epoxy resin as binder presents a linear dynamic range of 1.0×10-6 to 1.0×10-1 M with a Nernstian slope of 19.9 mV/decade. The sensor has a quick response time. (less than 10 s. The reproducibility of the electrode is about 6 months without any considerable, noticeable potential divergence. The sensor is effective in pH range of 3.00-8.62. In case of PVC as binding material; the results are compared for same composition of electro-active material. The sensor presents a linear dynamic range of 1.0×10-6 to 1.0×10-1 M with a slope of 14.0 mV/decade. The response time of the sensor is found to be 20s with a reproducibility of 4 months. The sensor is effective in pH range of 2.97-8.90. Effect of internal solution was studied and both the electrodes could satisfactorily be used in partially non-aqueous medium. Selectivity coefficients for both the electrodes have been determined by FIM (fixed interference method with respect to many rare earth metal ions, alkali & alkaline earth metal ions and some transition metal ions. Both the electrodes were successfully employed as indicator electrode in the potentiometric titration of Pr(III ions with oxalic acid and EDTA.

  5. Influence of different surface treatments on the short-term bond strength and durability between a zirconia post and a composite resin core material.

    Science.gov (United States)

    Akgungor, Gokhan; Sen, Deniz; Aydin, Murat

    2008-05-01

    Reliable bonding between zirconia posts and composite resin core materials is difficult to achieve because of the smooth surface texture and lack of silica content of zirconia posts. The purpose of this study was to evaluate the effect of different surface treatments on the short-term bond strength and durability between a zirconia post and a composite resin core material. Eighty zirconia posts were divided into 4 groups (n=20). Specimens received 1 of 4 different surface treatments: group AIRB, airborne-particle abrasion; group TSC-SIL, tribochemical silica coating (CoJet system) and silanization (ESPE Sil); group AIRB-BSIL, airborne-particle abrasion and MDP-containing primer (Clearfil SE Bond Primer)/silane coupling agent (Clearfil Porcelain Bond Activator) mixture application; and group TSC-BSIL, tribochemical silica coating and MDP-containing primer/silane coupling agent mixture application. Average surface roughness (Ra) of zirconia posts produced by airborne-particle abrasion or silica coating was measured using an optical profilometer. Composite resin core foundations (Build-it FR) were formed using transparent acrylic resin tubes (12mm in length and 7mm in diameter). Each group was further divided into 2 subgroups of 10 specimens and stored in distilled water at 37 degrees C, either for 24 hours or for 150 days with 37,500 thermal cycles between 5 degrees C and 55 degrees C, with a dwell time of 30 seconds. Following water storage, the specimens were sectioned perpendicular to the bonded interface into 2-mm-thick post-and-core specimens under water cooling. Push-out tests were performed with a universal testing machine at a crosshead speed of 0.5mm/min. Debonded post surfaces were examined with SEM. Data were analyzed with 1- and 2-way ANOVA and Tukey multiple comparison tests (alpha=0.05). No significant differences were detected between the Ra values of airborne-particle-abraded and silica-coated specimens (P=.781). The short-term mean bond strengths for

  6. Application of resin lining system for countermeasures for preventing leakage from openings in low temperature materials storage; Teion busshitsu chozoji no ekimore oyobi reiki more taisaku toshite no kobunshikei zairyo no tekiyosei

    Energy Technology Data Exchange (ETDEWEB)

    Inada, Y. [Ehime Univ., Ehime (Japan). Faculty of Engineering; Seki, S.

    1996-12-21

    Recently, many of the low temperature materials such as LNG and LPG used as an energy substitution for petroleum were stored in the reclaimed land of the sea side district, however, it is necessary for those storage methods to enlarge sites. Therefore, it was considered to directly store the low temperature materials in openings excavated in the rock mountains. However, countermeasures for leakage of liquid and cold gas from cracks in openings would be an important subject. In this study, as a countermeasure for leakage of liquid and cold gas in the case in which low temperature materials were stored in openings in the rock mountains, the lining of resin materials on the surface of openings was proposed. Characteristics of strength and deformation and values of the thermal physical properties for the resin materials at the low temperature were obtained by experiments. This material was compared with granite supposed as a parent rock, and the thermal property of the resin materials was understood. Next, an analysis was conducted in the case of using the resin materials as a lining, the behavior of the surrounding rocks of the openings and the stability of the lining were investigated. 17 refs., 25 figs., 2 tabs.

  7. Influence of 2% chlorhexidine on pH, calcium release and setting time of a resinous MTA-based root-end filling material.

    Science.gov (United States)

    Jacinto, Rogério Castilho; Linhares-Farina, Giane; Sposito, Otávio da Silva; Zanchi, César Henrique; Cenci, Maximiliano Sérgio

    2015-01-01

    The addition of chlorhexidine (CHX) to a resinous experimental Mineral Trioxide Aggregate (E-MTA) based root-end filling material is an alternative to boost its antimicrobial activity. However, the influence of chlorhexidine on the properties of this material is unclear. The aim of this study was to evaluate the influence of 2% chlorhexidine on the pH, calcium ion release and setting time of a Bisphenol A Ethoxylate Dimethacrylate/Mineral Trioxide Aggregate (Bis-EMA/MTA) based dual-cure experimental root-end filling material (E-MTA), in comparison with E-MTA without the addition of CHX and with conventional white MTA (W-MTA). The materials were placed in polyethylene tubes, and immersed in deionized water to determine pH (digital pH meter) and calcium ion release (atomic absorption spectrometry technique). The setting time of each material was analyzed using Gilmore needles. The data were statistically analyzed at a significance level of 5%. E-MTA + CHX showed an alkaline pH in the 3 h period of evaluation, the alkalinity of which decreased but remained as such for 15 days. The pH of E-MTA + CHX was higher than the other two materials after 7 days, and lower after 30 days (p pH and calcium ion release. However, it also prevented setting of the material.

  8. Physico-chemical study of the thermal degradation of ions exchange resins of nuclear origin: research of conditions to limit the pollution transfer, application to electric cables

    International Nuclear Information System (INIS)

    Antonetti, P.

    1999-01-01

    The ions exchange resins are one solid form of radioactive wastes. They are found mainly during the demineralization operations of the water from reactors cooling systems. This study aims to determine the conditions of a thermal processing leading to the production of a smaller residue, containing the whole activity. A protocol is proposed and validated on resins allowing a decrease of the volume of 63% for 99,93% of the activity. (A.L.B.)

  9. Use and Misuse of Material Transfer Agreements: Lessons in Proportionality from Research, Repositories, and Litigation

    OpenAIRE

    Bubela, Tania; Guebert, Jenilee; Mishra, Amrita

    2015-01-01

    Material transfer agreements exist to facilitate the exchange of materials and associated data between researchers as well as to protect the interests of the researchers and their institutions. But this dual mandate can be a source of frustration for researchers, creating administrative burdens and slowing down collaborations. We argue here that in most cases in pre-competitive research, a simple agreement would suffice; the more complex agreements and mechanisms for their negotiation should ...

  10. Heat transfer characteristics of coconut oil as phase change material to room cooling application

    Science.gov (United States)

    Irsyad, M.; Harmen

    2017-03-01

    Thermal comfort in a room is one of human needs in the workplace and dwellings, so that the use of air conditioning system in tropical countries is inevitable. This equipment has an impact on the increase of energy consumption. One method of minimizing the energy use is by using the phase change material (PCM) as thermal energy storage. This material utilizes the temperature difference between day and night for the storage and release of thermal energy. PCM development on application as a material for air cooling inlet, partitioning and interior needs to be supported by the study of heat transfer characteristics when PCM absorbs heat from ambient temperature. This study was conducted to determine the heat transfer characteristics on coconut oil as a phase change material. There are three models of experiments performed in this research. Firstly, an experiment was conducted to analyze the time that was needed by material to phase change by varying the temperature. The second experiment analyzed the heat transfer characteristics of air to PCM naturally convection. The third experiment analyzed the forced convection heat transfer on the surface of the PCM container by varying the air velocity. The data of experimental showed that, increasing ambient air temperature resulted in shorter time for phase change. At temperatures of 30°C, the time for phase change of PCM with the thickness of 8 cm was 1700 min, and it was stable at temperatures of 27°C. Increasing air temperature accelerated the phase change in the material. While for the forced convection heat transfer, PCM could reduce the air temperature in the range of 30 to 35°C at about 1 to 2°C, with a velocity of 1-3 m/s.

  11. Analysis of resin-dentin interface morphology and bond strength evaluation of core materials for one stage post-endodontic restorations.

    Directory of Open Access Journals (Sweden)

    Kerstin Bitter

    Full Text Available PURPOSE: Restoration of endodontically treated teeth using fiber posts in a one-stage procedure gains more popularity and aims to create a secondary monoblock. Data of detailed analyses of so called "post-and-core-systems" with respect to morphological characteristics of the resin-dentin interface in combination with bond strength measurements of fiber posts luted with these materials are scarce. The present study aimed to analyze four different post-and-core-systems with two different adhesive approaches (self-etch and etch-and-rinse. MATERIALS AND METHODS: Human anterior teeth (n = 80 were endodontically treated and post space preparations and post placement were performed using the following systems: Rebilda Post/Rebilda DC/Futurabond DC (Voco (RB, Luxapost/Luxacore Z/Luxabond Prebond and Luxabond A+B (DMG (LC, X Post/Core X Flow/XP Bond and Self Cure Activator (Dentsply DeTrey (CX, FRC Postec/MultiCore Flow/AdheSE DC (Ivoclar Vivadent (MC. Adhesive systems and core materials of 10 specimens per group were labeled using fluorescent dyes and resin-dentin interfaces were analyzed using Confocal Laser Scanning Microscopy (CLSM. Bond strengths were evaluated using a push-out test. Data were analyzed using repeated measurement ANOVA and following post-hoc test. RESULTS: CLSM analyses revealed significant differences between groups with respect to the factors hybrid layer thickness (p<0.0005 and number of resin tags (p = 0.02; ANOVA. Bond strength was significantly affected by core material (p = 0.001, location inside the root canal (p<0.0005 and incorporation of fluorescent dyes (p = 0.036; ANOVA. CX [7.7 (4.4 MPa] demonstrated significantly lower bond strength compared to LC [14.2 (8.7 MPa] and RB [13.3 (3.7 MPa] (p<0.05; Tukey HSD but did not differ significantly from MC [11.5 (3.5 MPa]. CONCLUSION: It can be concluded that bond strengths inside the root canal were not affected by the adhesive approach of the post-and-core-system. All systems

  12. Tensile and shear bond strength of hard and soft denture relining materials to the conventional heat cured acrylic denture base resin: An In-vitro study.

    Science.gov (United States)

    Lau, Mayank; Amarnath, G S; Muddugangadhar, B C; Swetha, M U; Das, Kopal Anshuraj Ashok Kumar

    2014-04-01

    The condition of the denture bearing tissues may be adversely affected by high stress concentration during function. Chairside Denture (Hard and Soft) reliners are used to distribute forces applied to soft tissues during function. Tensile and shear bond strength has been shown to be dependent on their chemical composition. A weak bond could harbor bacteria, promote staining and delamination of the lining material. To investigate tensile and shear bond strength of 4 different commercially available denture relining materials to conventional heat cured acrylic denture base resin. 4 mm sections in the middle of 160 Acrylic cylindrical specimens (20 mm x 8 mm) were removed, packed with test materials (Mollosil, G C Reline Soft, G C Reline Hard (Kooliner) and Ufi Gel Hard and polymerized. Specimens were divided into 8 groups of 20 each. Tensile and shear bond strength to the conventional heat cured acrylic denture base resin were examined by Instron Universal Tensile Testing Machine using the equation F=N/A (F-maximum force exerted on the specimen (Newton) and A-bonding area= 50.24 mm2). One-way ANOVA was used for multiple group comparisons followed by Bonferroni Test and Hsu's MCB for multiple pairwise comparisons to asses any significant differences between the groups. The highest mean Tensile bond strength value was obtained for Ufi Gel Hard (6.49+0.08 MPa) and lowest for G C Reline Soft (0.52+0.01 MPa). The highest mean Shear bond strength value was obtained for Ufi Gel Hard (16.19+0.1 MPa) and lowest for Mollosil (0.59+0.05 MPa). The Benferroni test showed a significant difference in the mean tensile bond strength and the mean shear bond strength when the two denture soft liners were compared as well as when the two denture hard liners were compared. Hsu's MCB implied that Ufi gel hard is better than its other closest competitors. The Tensile and Shear bond strength values of denture soft reliners were significantly lower than denture hard reliners. How to cite the

  13. Thermal Response and Stability Characteristics of Bistable Composite Laminates by Considering Temperature Dependent Material Properties and Resin Layers

    Science.gov (United States)

    Moore, M.; Ziaei-Rad, S.; Salehi, H.

    2013-02-01

    In this study, the stability characteristics and thermal response of a bistable composite plate with different asymmetric composition were considered. The non-linear finite element method (FEM) was utilized to determine the response of the laminate. Attention was focused on the temperature dependency of laminate mechanical properties, especially on the thermal expansion coefficients of the composite graphite-epoxy plate. Also the effect of including the resin layers on the stability characteristics of the laminate was investigated. The effect of the temperature on the laminate cured configurations in the range of 25°C to 180°C and -60°C to 40°C was examined. The results indicate that the coefficient of thermal expansions has a major effect on the cured shapes. Next, optical microscopy was used to characterize the laminate composition and for the first time the effect of including the resin layers on the actuation loads that causes snapping behavior between two stable shapes was studied. The results obtained from the finite element simulations were compared with experimental results and a good correlation was obtained. Finally, the stability characteristics of a tapered composite panel were investigated for using in a sample winglet as a candidate application of bistable structures.

  14. Plastic casting resin poisoning

    Science.gov (United States)

    Epoxy poisoning; Resin poisoning ... Epoxy and resin can be poisonous if they are swallowed or their fumes are breathed in. ... Plastic casting resins are found in various plastic casting resin products.

  15. Influence of different luting protocols on shear bond strength of computer aided design/computer aided manufacturing resin nanoceramic material to dentin

    Directory of Open Access Journals (Sweden)

    Claudio Poggio

    2016-01-01

    Conclusion: Within the limitations of this in vitro study, conventional resin cements (coupled with etch and rinse or self-etch adhesives showed better shear strength values compared to self-adhesive resin cements. Furthermore, conventional resin cements used together with a self-etch adhesive reported the highest values of adhesion.

  16. Recycling of plastic group composite materials. 3. ; Current situation in recycling of thermosetting resin composite materials in Japan, Europe and America. Plastic ki fukugo zairyo no recycle. 3. ; Netsukokasei jushi fukugo zairyo no recycle no Nichiobei no genjo

    Energy Technology Data Exchange (ETDEWEB)

    Iimori, H. (Mitsui Toatsu Chemicals, Inc., Tokyo (Japan))

    1993-07-15

    This paper describes the current situation in Japan, Europe and America on recycling of thermosetting resin composite materials, and material treatment and resource re-utilization with emphasis on FRP. Land reclamation would become impossible eventually as a result of difficulty in land procurement, soil contamination, and residents' objection. Pulverization consists of a flow comprising disassembling, cutting, crushing, pulverization, and classification. Pyrolysis heats materials in steam, oxygen-free or low-oxygen atmosphere to recover combustible gases, oils, and resin material solids. Incineration requires incinerator designs that take into account incinerator damages due to black smoke and molten glassfibers. Japan, Europe, and America which have common environmental and legislative regulation issues have begun researches simultaneously. Europe has advanced with pulverization systems in reaching practical use levels, and North America has been using the systems practically. The pyrolytic means are in a feasibility study phase. The issue of the car scrapping law in Germany is inevitable to become a common problem for the EC countries. The automobile industries in North America have been working on technical development under joint investments. Treatment technologies in Japan have nearly reached the levels in Europe and America. Responses to structural change requirements from consumption type to environmental protection type are required. 14 refs., 8 figs., 7 tabs.

  17. Heat transfer characteristics of thermal energy storage for PCM (phase change material) melting in horizontal tube: Numerical and experimental investigations

    International Nuclear Information System (INIS)

    Aadmi, Moussa; Karkri, Mustapha; El Hammouti, Mimoun

    2015-01-01

    This paper focuses on the experimental and numerical study of the storage and release of thermal heat during melting and solidification of PCM (phase change material). Heat transfer enhancement techniques such as the use of conductors like graphite and metal tubes have been proven to be effective. The material used for thermal energy storage systems is a composite based on epoxy resin loaded with metal hollow tubes filled with paraffin wax. Differential Scanning Calorimetry has been used for measurement of melting enthalpy and determination of heat capacity. The thermophysical properties of the prepared composite phase change material have been characterized using a new transient hot plate apparatus. The results have shown that most important thermal properties of these composites at the solid and liquid states are the ‘‘apparent’’ thermal conductivity, the heat storage capacity and the latent heat of fusion. These experimental results have been simulated using numerical Comsol ® Multiphysics 4.3 based models with success. The results of the experimental investigation are compared favorably with the numerical results and thus serve to validate the numerical approach. - Highlights: • Phase change materials based on cylindrical used as new energy storage system. • Thermophysical properties and the melting process of composites were investigated. • All experimental results have been simulated using Comsol ® Multiphysiques. • The ability to store and release the thermal energy were investigated. • Good improvement in the thermal conductivity of composites

  18. Model Property Based Material Balance and Energy Conservation Analysis for Process Industry Energy Transfer Systems

    Directory of Open Access Journals (Sweden)

    Fumin Ma

    2015-10-01

    Full Text Available Conventional historical data based material and energy balance analyses are static and isolated computations. Such methods cannot embody the cross-coupling effect of energy flow, material flow and information flow in the process industry; furthermore, they cannot easily realize the effective evaluation and comparison of different energy transfer processes by alternating the model module. In this paper, a novel method for material balance and energy conservation analysis of process industry energy transfer system is developed based on model property. Firstly, a reconfigurable energy transfer process model, which is independent of energy types and energy-consuming equipment, is presented from the viewpoint of the cross-coupling effect of energy flow, material flow and information flow. Thereafter the material balance determination is proposed based on both a dynamic incidence matrix and dynamic balance quantity. Moreover, the model-weighted conservation determination theorem is proved, and the energy efficiency analysis method is also discussed. Results confirmed the efficacy of the proposed methods, confirming its potential for use by process industry in energy efficiency analyses.

  19. Review on thermal energy storage with phase change: materials, heat transfer analysis and applications

    Energy Technology Data Exchange (ETDEWEB)

    Zalba, Belen; Marin, Jose M. [Dpto. Ingenieria Mecanica, Campus Politecnico, Universidad de Zaragoza, EUITIZ ' EDIFICIO B.3' Maria de Luna 3 (Actur), 50015, Zaragoza (Spain); Cabeza, Luisa F. [Dpt.d' Informatica i Enginyeria Industrial, Escola, Universitaria Politecnica, Universitat de Lleida, CREA, Jaurne 11,69,25001, Lleida (Spain); Mehling, Harald [ZAE Bayem, Division 1: Energy Conversion and Storage, Walther-Meissner-Str. 6, 85748, Garching (Germany)

    2003-02-01

    Thermal energy storage in general, and phase change materials (PCMs) in particular, have been a main topic in research for the last 20 years, but although the information is quantitatively enormous, it is also spread widely in the literature, and difficult to find. In this work, a review has been carried out of the history of thermal energy storage with solid-liquid phase change. Three aspects have been the focus of this review: materials, heat transfer and applications. The paper contains listed over 150 materials used in research as PCMs, and about 45 commercially available PCMs. The paper lists over 230 references. (Author)

  20. Optimization on microlattice materials for sound absorption by an integrated transfer matrix method.

    Science.gov (United States)

    Cai, Xiaobing; Yang, Jun; Hu, Gengkai

    2015-04-01

    Materials with well-defined microlattice structures are superlight, stable, and thus bear great potential in sound absorption. An integrated transfer matrix method (TMM) is proposed to evaluate the sound absorbing efficiency of these lattice materials, in which a massive number of micropores are densely placed. A comparison between integrated TMM and conventional TMM reveals that the proposed approach offers better predictions on sound absorption of microlattice. This approach is then employed to optimize the microlattice material to determine the best pore and porosity that lead to maximum absorbing efficiency capability and minimum required thickness to attain a target sound absorption.

  1. Experimental Investigation on Material Transfer Mechanism in WEDM of Pure Titanium (Grade-2

    Directory of Open Access Journals (Sweden)

    Anish Kumar

    2013-01-01

    Full Text Available This research work mainly focused on experimental investigation on material transfer mechanism in WEDM of pure titanium. The effects of machining parameters such as pulse on time, pulse off time, peak current, spark gap voltage, wire feed, and wire tension on the material removal rate (MRR, overcut, and surface roughness for pure titanium in WEDM process were explored. The selected machined samples were analyzed using energy dispersive X-ray analysis, scanning electron microscope, and X-ray diffraction techniques. It was observed from the results that a significant material transfer occurred from the dielectric, as well as tool, electrode on the work surface either in free form and/or in compound form. Also the multiresponse optimization of process parameters was done using desirability approach. The predictions from this model were validated by conducting experiments.

  2. The Effect of Anisotropy of Building Materials on the Moisture Transfer

    Directory of Open Access Journals (Sweden)

    J. Drchalová

    2000-01-01

    Full Text Available The effect of anisotropy of building materials on the moisture transfer in the design of envelope parts of building structures is studied. Two typical fibre containing plate building materials produced in the Czech Republic, Dekalux and Dekalit P, are chosen for the demonstration of this effect. Experimental results show that while for lighter Dekalit P, an order of magnitude difference in the moisture diffusivities k for the two basic orientations, i.e. along and across the plate, is observed, for the heavier Dekalux the differences in k are within the errorbar of the experimental method. As follows from the experimental results, compacting of surface layers of the plates of light fibred materials is very favorable from the point of view of moisture penetration but one should keep in mind that any local damage of the surface layer can result in a considerably faster moisture transfer in the direction along the plate.

  3. Methods for associating or dissociating guest materials with a metal organic framework, systems for associating or dissociating guest materials within a series of metal organic frameworks, thermal energy transfer assemblies, and methods for transferring thermal energy

    Science.gov (United States)

    McGrail, B. Peter; Brown, Daryl R.; Thallapally, Praveen K.

    2016-08-02

    Methods for releasing associated guest materials from a metal organic framework are provided. Methods for associating guest materials with a metal organic framework are also provided. Methods are provided for selectively associating or dissociating guest materials with a metal organic framework. Systems for associating or dissociating guest materials within a series of metal organic frameworks are provided. Thermal energy transfer assemblies are provided. Methods for transferring thermal energy are also provided.

  4. Resin composites

    DEFF Research Database (Denmark)

    Benetti, Ana Raquel; Peutzfeldt, Anne; Lussi, Adrian

    2014-01-01

    OBJECTIVE: To investigate how the modulus of elasticity of resin composites influences marginal quality in restorations submitted to thermocyclic and mechanical loading. METHODS: Charisma, Filtek Supreme XTE and Grandio were selected as they were found to possess different moduli of elasticity...... of resin composite (p=0.81) on the quality of dentine margins was observed, before or after loading. Deterioration of all margins was evident after loading (p....008). CONCLUSIONS: The resin composite with the highest modulus of elasticity resulted in the highest number of gap-free enamel margins but with an increased incidence of paramarginal enamel fractures. CLINICAL SIGNIFICANCE: The results from this study suggest that the marginal quality of restorations can...

  5. The effects of silane-SiO2 nanocomposite films on Candida albicans adhesion and the surface and physical properties of acrylic resin denture base material.

    Science.gov (United States)

    Yodmongkol, Sirasa; Chantarachindawong, Rojcharin; Thaweboon, Sroisiri; Thaweboon, Boonyanit; Amornsakchai, Taweechai; Srikhirin, Toemsak

    2014-12-01

    Polysiloxane has been used as a coupling material in restorative dental materials for several decades. However, few studies are available on the application of polysiloxane in other dental prosthesis functions. The purpose of this study was to investigate the effects of silane-SiO2 nanocomposite films on Candida albicans adhesion and the surface and physical properties of acrylic resin denture base materials. Specimens were separated into 2 groups, uncoated and coated. They were coated with a film by using the dip-coating method. Specimens were incubated with Candida albicans 10(7) cells/mL for 1 hour, and the adherent cells were counted under an optical microscope. The following surface properties were measured: surface chemical composition with Fourier-transform infrared spectrometry, surface roughness with a surface profiler, surface energy with the sessile drop method, and surface hardness with a microhardness tester. The physical properties, including water sorption, water solubility, ultimate flexural strength, and flexural modulus, were evaluated according to International Organization for Standardization 20795-1 requirements. The adhesion of Candida albicans and the surface properties of the specimens were investigated after cleaning with effervescent tablets and brushing. An MTT assay was used to evaluate the coated specimens. The results were statistically analyzed with the Mann-Whitney U test (α=.05). A significant reduction in Candida albicans adhesion (P=.002) was observed before cleaning. In addition, the surface energy was comparable (P=.100), the surface hardness increased significantly (P=.008), and the surface roughness remained unchanged (P=.310). After cleaning with effervescent tablets, a significant decrease in Candida albicans adhesion (P=.002) and in surface roughness (P=.008) was observed; however, similar surface energies were measured (P=.100). After cleaning with a toothbrush, the adhesion of Candida albicans was significantly higher on

  6. Applications of free-electron lasers to measurements of energy transfer in biopolymers and materials

    Science.gov (United States)

    Edwards, Glenn S.; Johnson, J. B.; Kozub, John A.; Tribble, Jerri A.; Wagner, Katrina

    1992-08-01

    Free-electron lasers (FELs) provide tunable, pulsed radiation in the infrared. Using the FEL as a pump beam, we are investigating the mechanisms for energy transfer between localized vibrational modes and between vibrational modes and lattice or phonon modes. Either a laser-Raman system or a Fourier transform infrared (FTIR) spectrometer will serve as the probe beam, with the attribute of placing the burden of detection on two conventional spectroscopic techniques that circumvent the limited response of infrared detectors. More specifically, the Raman effect inelastically shifts an exciting laser line, typically a visible frequency, by the energy of the vibrational mode; however, the shifted Raman lines also lie in the visible, allowing for detection with highly efficient visible detectors. With regards to FTIR spectroscopy, the multiplex advantage yields a distinct benefit for infrared detector response. Our group is investigating intramolecular and intermolecular energy transfer processes in both biopolymers and more traditional materials. For example, alkali halides contain a number of defect types that effectively transfer energy in an intermolecular process. Similarly, the functioning of biopolymers depends on efficient intramolecular energy transfer. Understanding these mechanisms will enhance our ability to modify biopolymers and materials with applications to biology, medecine, and materials science.

  7. Low cost transportable device for transference of atmosphere sensitive materials from glove box to SEM

    DEFF Research Database (Denmark)

    Bentzen, Janet Jonna; Saxild, Finn B.

    the field of high energy battery research involving highly reactive metals, e.g. lithium, we needed a means of transferring atmosphere sensitive materials from the protective atmosphere of a glove box, avoiding air exposure, to a sample chamber of a scanning electron microscope. Thus, we constructed a low...... cost transportable device. The transportable transfer device holding a small evacuable chamber was constructed from a valve fitted with adapters to a glove box and a scanning electron microscope (JEOL 840). Examples of the application to high energy battery research are illustrated....

  8. Numerical modeling of nonisothermal moisture transfer in biological colloidal porous materials

    Science.gov (United States)

    Strumillo, C.; Grinchik, N. N.; Kuts, P. S.; Akulich, P. V.; Zbicinski, I.

    1994-02-01

    The authors derive and substantiate a system of equations of heat and moisture transfer in colloidal capillary-porous undersaturated media with account for the mutual effect of the vapor and liquid pressure, determined by the contribution of surface forces, and the temperature on the rate of interphase mass transfer and the thermocapillary flows. Examples are given of the numerical calculation of evolution of the moisture content and temperature fields and the kinetic dependences in a wide moisture content range for materials of biological origin, namely, yeast, soil. A comparison is made with experimental data.

  9. Influence of 2% chlorhexidine on pH, calcium release and setting time of a resinous MTA-based root-end filling material

    Directory of Open Access Journals (Sweden)

    Rogério Castilho JACINTO

    2015-01-01

    Full Text Available The addition of chlorhexidine (CHX to a resinous experimental Mineral Trioxide Aggregate (E-MTA based root-end filling material is an alternative to boost its antimicrobial activity. However, the influence of chlorhexidine on the properties of this material is unclear. The aim of this study was to evaluate the influence of 2% chlorhexidine on the pH, calcium ion release and setting time of a Bisphenol A Ethoxylate Dimethacrylate/Mineral Trioxide Aggregate (Bis-EMA/MTA based dual-cure experimental root-end filling material (E-MTA, in comparison with E-MTA without the addition of CHX and with conventional white MTA (W-MTA. The materials were placed in polyethylene tubes, and immersed in deionized water to determine pH (digital pH meter and calcium ion release (atomic absorption spectrometry technique. The setting time of each material was analyzed using Gilmore needles. The data were statistically analyzed at a significance level of 5%. E-MTA + CHX showed an alkaline pH in the 3 h period of evaluation, the alkalinity of which decreased but remained as such for 15 days. The pH of E-MTA + CHX was higher than the other two materials after 7 days, and lower after 30 days (p < 0.05. All of the materials were found to release calcium ions throughout the 30 days of the study. The addition of CHX increased the calcium ion release of E-MTA to levels statistically similar to W-MTA. E-MTA showed shorter initial and final setting time, compared with W-MTA (p < 0.05. The addition of 2% CHX to MTA prevented setting of the material. The addition of CHX to E-MTA increased its pH and calcium ion release. However, it also prevented setting of the material.

  10. Experimental and analytical investigations of granular materials: Shear flow and convective heat transfer

    Science.gov (United States)

    Ahn, Hojin

    1989-12-01

    Granular materials flowing down an inclined chute were studied experimentally and analytically. Characteristics of convective heat transfer to granular flows were also investigated experimentally and numerically. Experiments on continuous, steady flows of granular materials in an inclined chute were conducted with the objectives of understanding the characteristics of chute flows and of acquiring information on the rheological behavior of granular material flow. Existing constitutive equations and governing equations were used to solve for fully developed chute flows of granular materials, and thus the boundary value problem was formulated with two parameters (the coefficient of restitution between particles, and the chute inclination) and three boundary values at the chute base wall (the values of solid fraction, granular temperature, and mean velocity at the wall). The boundary value problem was numerically solved by the shooting method. These analytical results were also compared with the present experimental values and with the computer simulations by other investigators in their literature. Experiments on heat transfer to granular flows over a flat heating plate were conducted with three sizes of glass beads, polystyrene beads, and mustard seeds. A modification on the existing model for the convective heat transfer was made using the effective Nusselt number and the effective Peclet number, which include the effects of solid fraction variations. The slightly modified model could describe the heat transfer characteristics of both fast and slow flows (supercritical and subcritical). A numerical analysis of the transfer to granular flows was also performed. The results were compared with the present experimental data, and reasonable agreement was found in the comparison.

  11. The simulation calculation of acoustics energy transfer through the material structure

    Directory of Open Access Journals (Sweden)

    Zvolenský Peter

    2016-01-01

    Full Text Available The paper deals with the modification of the rail passenger coach floor design aimed at improvement of sound reduction index. Refurbishing was performed by using a new acoustic material with a filamentary microstructure. The materials proposed in research were compared by simulation calculation of acoustic energy transfer trough porous microstructure of filamentary material, and the effect of material porosity on sound reduction index and sound absorption coefficient were observed. This proposed filamentary material can be used in the railway bed structure, too. High degree of noise absorbing, resistance to climate conditions, low specific mass, enable to choose a system of low anti-noise barriers having similar properties as standard high anti-noise walls..

  12. Modeling the Residual Stresses in Reactive Resins-Based Materials: a Case Study of Photo-Sensitive Composites for Dental Applications

    Science.gov (United States)

    Grassia, Luigi; D'Amore, Alberto

    2010-06-01

    Residual stresses in reactive resins-based composites are associated to the net volumetric contraction (shrinkage) arising during the cross-linking reactions. Depending on the restoration geometry (the ratio of the free surface area to the volume of the cavity) the frozen-in stresses can be as high as the strength of the dental composites. This is the main reason why the effectiveness and then the durability of restorations with composites remains quite lower than those realized with metal alloys based materials. In this paper we first explore the possibility to circumvent the mathematical complexity arising from the determination of residual stresses in reactive systems three-dimensionally constrained. Then, the results of our modeling approach are applied to a series of commercially available composites showing that almost all samples develop residual stresses such that the restoration undergoes failure as soon as it is realized.

  13. Modeling the Residual Stresses in Reactive Resins-Based Materials: a Case Study of Photo-Sensitive Composites for Dental Applications

    International Nuclear Information System (INIS)

    Grassia, Luigi; D'Amore, Alberto

    2010-01-01

    Residual stresses in reactive resins-based composites are associated to the net volumetric contraction (shrinkage) arising during the cross-linking reactions. Depending on the restoration geometry (the ratio of the free surface area to the volume of the cavity) the frozen-in stresses can be as high as the strength of the dental composites. This is the main reason why the effectiveness and then the durability of restorations with composites remains quite lower than those realized with metal alloys based materials. In this paper we first explore the possibility to circumvent the mathematical complexity arising from the determination of residual stresses in reactive systems three-dimensionally constrained. Then, the results of our modeling approach are applied to a series of commercially available composites showing that almost all samples develop residual stresses such that the restoration undergoes failure as soon as it is realized.

  14. Evaluation of the bond strength of different adhesive agents to a resin-modified calcium silicate material (TheraCal LC).

    Science.gov (United States)

    Karadas, Muhammed; Cantekin, Kenan; Gumus, Husniye; Ateş, Sabit Melih; Duymuş, Zeynep Yesil

    2016-09-01

    This study evaluated the bond strength of different adhesive agents to TheraCal LC and mineral trioxide aggregate (MTA) and examined the morphologic changes of these materials with different surface treatments. A total of 120 specimens, 60 of MTA Angelus (AMTA), and 60 of TheraCal LC, were prepared and divided into six subgroups according to the adhesive agent used; these agents included Scotchbond Multipurpose, Clearfil SE Bond, Clearfil Protect Bond, Clearfil S 3 Bond, OptiBond All-in-One, and G-aenial Bond. After application of adhesive agents, Filtek Z250 composite resin was placed onto the specimens. Shear bond strengths were measured using a universal testing machine, followed by examination of the fractured surfaces. The surface changes of the specimens were observed using scanning electron microscopy. Data were compared by two-way analysis of variance. Although no significant differences were found among the bond strengths of different adhesives to AMTA (p = 0.69), a significant difference was found in terms of bond strengths of different adhesives to the TheraCal LC surface (p TheraCal LC compared to the bond with other adhesives. TheraCal LC bonded significantly more strongly than AMTA regardless of the adhesive agents tested. Resin-modified calcium silicate showed higher bond strength than AMTA in terms of the composite bond to these materials with different bonding systems. On the other hand, the highest shear bond-strength values were found for composite bonds with the combination of TheraCal LC and the total-etch adhesive system. SCANNING 38:403-411, 2016. © 2015 Wiley Periodicals, Inc. © Wiley Periodicals, Inc.

  15. Surface hardness evaluation of different composite resin materials: influence of sports and energy drinks immersion after a short-term period.

    Science.gov (United States)

    Erdemir, Ugur; Yildiz, Esra; Eren, Meltem Mert; Ozel, Sevda

    2013-01-01

    This study evaluated the effect of sports and energy drinks on the surface hardness of different composite resin restorative materials over a 1-month period. A total of 168 specimens: Compoglass F, Filtek Z250, Filtek Supreme, and Premise were prepared using a customized cylindrical metal mould and they were divided into six groups (N=42; n=7 per group). For the control groups, the specimens were stored in distilled water for 24 hours at 37°C and the water was renewed daily. For the experimental groups, the specimens were immersed in 5 mL of one of the following test solutions: Powerade, Gatorade, X-IR, Burn, and Red Bull, for two minutes daily for up to a 1-month test period and all the solutions were refreshed daily. Surface hardness was measured using a Vickers hardness measuring instrument at baseline, after 1-week and 1-month. Data were statistically analyzed using Multivariate repeated measure ANOVA and Bonferroni's multiple comparison tests (α=0.05). Multivariate repeated measures ANOVA revealed that there were statistically significant differences in the hardness of the restorative materials in different immersion times (psports and energy drinks after a 1-month evaluation period (psports and energy drinks on the surface hardness of a restorative material depends on the duration of exposure time, and the composition of the material.

  16. Heat transfer characteristics of liquid-gas Taylor flows incorporating microencapsulated phase change materials

    International Nuclear Information System (INIS)

    Howard, J A; Walsh, P A

    2014-01-01

    This paper presents an investigation on the heat transfer characteristics associated with liquid-gas Taylor flows in mini channels incorporating microencapsulated phase change materials (MPCM). Taylor flows have been shown to result in heat transfer enhancements due to the fluid recirculation experienced within liquid slugs which is attributable to the alternating liquid slug and gas bubble flow structure. Microencapsulated phase change materials (MPCM) also offer significant potential with increased thermal capacity due to the latent heat required to cause phase change. The primary aim of this work was to examine the overall heat transfer potential associated with combining these two novel liquid cooling technologies. By investigating the local heat transfer characteristics, the augmentation/degradation over single phase liquid cooling was quantified while examining the effects of dimensionless variables, including Reynolds number, liquid slug length and gas void fraction. An experimental test facility was developed which had a heated test section and allowed MPCM-air Taylor flows to be subjected to a constant heat flux boundary condition. Infrared thermography was used to record high resolution experimental wall temperature measurements and determine local heat transfer coefficients from the thermal entrance point. 30.2% mass particle concentration of the MPCM suspension fluid was examined as it provided the maximum latent heat for absorption. Results demonstrate a significant reduction in experimental wall temperatures associated with MPCM-air Taylor flows when compared with the Graetz solution for conventional single phase coolants. Total enhancement in the thermally developed region is observed to be a combination of the individual contributions due to recirculation within the liquid slugs and also absorption of latent heat. Overall, the study highlights the potential heat transfer enhancements that are attainable within heat exchange devices employing MPCM

  17. Charge-transfer channel in quantum dot-graphene hybrid materials

    Science.gov (United States)

    Cao, Shuo; Wang, Jingang; Ma, Fengcai; Sun, Mengtao

    2018-04-01

    The energy band theory of a classical semiconductor can qualitatively explain the charge-transfer process in low-dimensional hybrid colloidal quantum dot (QD)-graphene (GR) materials; however, the definite charge-transfer channels are not clear. Using density functional theory (DFT) and time-dependent DFT, we simulate the hybrid QD-GR nanostructure, and by constructing its orbital interaction diagram, we show the quantitative coupling characteristics of the molecular orbitals (MOs) of the hybrid structure. The main MOs are derived from the fragment MOs (FOs) of GR, and the Cd13Se13 QD FOs merge with the GR FOs in a certain proportion to afford the hybrid system. Upon photoexcitation, electrons in the GR FOs jump to the QD FOs, leaving holes in the GR FOs, and the definite charge-transfer channels can be found by analyzing the complex MOs coupling. The excited electrons and remaining holes can also be localized in the GR or the QD or transfer between the QD and GR with different absorption energies. The charge-transfer process for the selected excited states of the hybrid QD-GR structure are testified by the charge difference density isosurface. The natural transition orbitals, charge-transfer length analysis and 2D site representation of the transition density matrix also verify the electron-hole delocalization, localization, or coherence chacracteristics of the selected excited states. Therefore, our research enhances understanding of the coupling mechanism of low-dimensional hybrid materials and will aid in the design and manipulation of hybrid photoelectric devices for practical application in many fields.

  18. Charge-transfer channel in quantum dot-graphene hybrid materials.

    Science.gov (United States)

    Cao, Shuo; Wang, Jingang; Ma, Fengcai; Sun, Mengtao

    2018-04-06

    The energy band theory of a classical semiconductor can qualitatively explain the charge-transfer process in low-dimensional hybrid colloidal quantum dot (QD)-graphene (GR) materials; however, the definite charge-transfer channels are not clear. Using density functional theory (DFT) and time-dependent DFT, we simulate the hybrid QD-GR nanostructure, and by constructing its orbital interaction diagram, we show the quantitative coupling characteristics of the molecular orbitals (MOs) of the hybrid structure. The main MOs are derived from the fragment MOs (FOs) of GR, and the Cd 13 Se 13 QD FOs merge with the GR FOs in a certain proportion to afford the hybrid system. Upon photoexcitation, electrons in the GR FOs jump to the QD FOs, leaving holes in the GR FOs, and the definite charge-transfer channels can be found by analyzing the complex MOs coupling. The excited electrons and remaining holes can also be localized in the GR or the QD or transfer between the QD and GR with different absorption energies. The charge-transfer process for the selected excited states of the hybrid QD-GR structure are testified by the charge difference density isosurface. The natural transition orbitals, charge-transfer length analysis and 2D site representation of the transition density matrix also verify the electron-hole delocalization, localization, or coherence chacracteristics of the selected excited states. Therefore, our research enhances understanding of the coupling mechanism of low-dimensional hybrid materials and will aid in the design and manipulation of hybrid photoelectric devices for practical application in many fields.

  19. Bulk-Fill Resin Composites

    DEFF Research Database (Denmark)

    Benetti, Ana Raquel; Havndrup-Pedersen, Cæcilie; Honoré, Daniel

    2015-01-01

    the restorative procedure. The aim of this study, therefore, was to compare the depth of cure, polymerization contraction, and gap formation in bulk-fill resin composites with those of a conventional resin composite. To achieve this, the depth of cure was assessed in accordance with the International Organization...... for Standardization 4049 standard, and the polymerization contraction was determined using the bonded-disc method. The gap formation was measured at the dentin margin of Class II cavities. Five bulk-fill resin composites were investigated: two high-viscosity (Tetric EvoCeram Bulk Fill, SonicFill) and three low......-viscosity (x-tra base, Venus Bulk Fill, SDR) materials. Compared with the conventional resin composite, the high-viscosity bulk-fill materials exhibited only a small increase (but significant for Tetric EvoCeram Bulk Fill) in depth of cure and polymerization contraction, whereas the low-viscosity bulk...

  20. A Polarizable and Transferable PHAST CO 2 Potential for Materials Simulation

    KAUST Repository

    Mullen, Ashley L.

    2013-12-10

    Reliable PHAST (Potentials with High Accuracy Speed and Transferability) intermolecular potential energy functions for CO2 have been developed from first principles for use in heterogeneous systems, including one with explicit polarization. The intermolecular potentials have been expressed in a transferable form and parametrized from nearly exact electronic structure calculations. Models with and without explicit many-body polarization effects, known to be important in simulation of interfacial processes, are constructed. The models have been validated on pressure-density isotherms of bulk CO 2 and adsorption in three metal-organic framework (MOF) materials. The present models appear to offer advantages over high quality fluid/liquid state potentials in describing CO2 interactions in interfacial environments where sorbates adopt orientations not commonly explored in bulk fluids. Thus, the nonpolar CO2-PHAST and polarizable CO 2-PHAST* potentials are recommended for materials/interfacial simulations. © 2013 American Chemical Society.

  1. Step scaling and behaviour selection in a constrained set of manual material handling transfers.

    Science.gov (United States)

    Wagner, David W; Reed, Matthew P

    2013-01-01

    Predictive biomechanical analysis of manual material handling (MMH) transfers is dependent on accurate prediction of foot locations relative to the task. Previous studies have classified common acyclic stepping patterns used during those transfer tasks, but the influence of walking distance prior to the transfer is not well understood. Twenty men and women performed transfers for a minimum of six different delivery distance conditions. The number of steps used by the participants ranged from two to seven. A theoretical framework for idealised step-scaling strategies is proposed and compared with the experimental data. The maximum observed increase in step length prior to delivery was 1.43 times the nominal step length calculated for each participant. The data suggest that although participants can scale their steps to facilitate the use of a single terminal stance at the transfer, the majority of participants chose to utilise a combination of stepping strategies if the preferred contralateral lead foot strategy could not be easily implemented. Accurate foot placements are needed for predictive biomechanical analysis of MMH. A laboratory study investigated the influence of previous step positions on MMH. A flexible step-scaling strategy, in which step lengths and strategy were varied, suggests that analysis based on simulated movements should consider multiple lifting postures.

  2. A comprehensive study of soft magnetic materials based on FeSi spheres and polymeric resin modified by silica nanorods

    Czech Academy of Sciences Publication Activity Database

    Strečková, M.; Füzer, J.; Kobera, Libor; Brus, Jiří; Fáberová, M.; Bureš, R.; Kollár, P.; Lauda, M.; Medvecký, L.; Girman, V.; Hadraba, Hynek; Baťková, M.; Baťko, I.

    2014-01-01

    Roč. 147, č. 3 (2014), s. 649-660 ISSN 0254-0584 Institutional support: RVO:61389013 ; RVO:68081723 Keywords : composite materials * magnetic materials * chemical synthesis Subject RIV: CD - Macromolecular Chemistry; JH - Ceramics, Fire-Resistant Materials and Glass (UFM-A) Impact factor: 2.259, year: 2014

  3. Toward Hybrid Materials: Group Transfer Polymerization of 3-(Trimethoxysilyl)propyl Methacrylate.

    Science.gov (United States)

    Chung, Justin J; Jones, Julian R; Georgiou, Theoni K

    2015-10-01

    In this study, the group transfer polymerization (GTP) of the functional monomer 3-(trimethoxysilyl)propyl methacrylate (TMSPMA) is reported to produce polymers of different architectures and topologies. TMSPMA is successfully polymerized and copolymerized with GTP to produce well-defined (co)polymers that can be used to fabricate functional hybrid materials like hydrogels and films. © 2015 The Authors. Published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Use and misuse of material transfer agreements: lessons in proportionality from research, repositories, and litigation.

    Directory of Open Access Journals (Sweden)

    Tania Bubela

    2015-02-01

    Full Text Available Material transfer agreements exist to facilitate the exchange of materials and associated data between researchers as well as to protect the interests of the researchers and their institutions. But this dual mandate can be a source of frustration for researchers, creating administrative burdens and slowing down collaborations. We argue here that in most cases in pre-competitive research, a simple agreement would suffice; the more complex agreements and mechanisms for their negotiation should be reserved for cases where the risks posed to the institution and the potential commercial value of the research reagents is high.

  5. Use and misuse of material transfer agreements: lessons in proportionality from research, repositories, and litigation.

    Science.gov (United States)

    Bubela, Tania; Guebert, Jenilee; Mishra, Amrita

    2015-02-01

    Material transfer agreements exist to facilitate the exchange of materials and associated data between researchers as well as to protect the interests of the researchers and their institutions. But this dual mandate can be a source of frustration for researchers, creating administrative burdens and slowing down collaborations. We argue here that in most cases in pre-competitive research, a simple agreement would suffice; the more complex agreements and mechanisms for their negotiation should be reserved for cases where the risks posed to the institution and the potential commercial value of the research reagents is high.

  6. Numerical study of heat transfer from a wall incorporating a phase change material

    Directory of Open Access Journals (Sweden)

    Bouttout A.

    2013-03-01

    Full Text Available A numerical study of the thermal behavior of walls made up of construction materials used in Algeria and walls containing a phase change materials is presented. The model, based on the enthalpy formulation, is described by an equation of heat transfer. This equation is solved by an implicit method of finite differences and algorithm of Thomas. We analyzed the influence of the wall’s thickness and its composition on the evolution during the time of the temperature of the inside face of thewall.

  7. On Heat Transfer Analysis for a Sphere of Combustible Material of Variable Thermal Conductivity

    Science.gov (United States)

    Lebelo, Ramoshweu Solomon; Kebarapetse Mahlobo, Radley; Olumide Adesanya, Samuel; Sundaram Muthuvalu, Mohana

    2017-11-01

    This article considers an exothermic chemical reaction taking place in a stockpile of reactive material with a thermal conductivity that is temperature dependent. The study is modeled in a spherical domain whose carbon-containing material reacts spontaneously with the oxygen trapped within the system. The combustion process results with a complicated process that is nonlinear in nature, and the energy equation used to govern the problem is tackled numerically with the semi-implicit finite difference method (FDM). The results are depicted graphically and discussed to give a theoretical understanding of the heat transfer analysis during combustion.

  8. Experimental study of dynamic effects in moisture transfer in building materials

    DEFF Research Database (Denmark)

    Janssen, Hans; Scheffler, Gregor Albrecht; Plagge, Rudolf

    2016-01-01

    of the moisture transfer processes involved. The available evidence primarily stems from imbibition and drainage experiments on soils however, and compared to many other porous media, these tests consider rather permeable materials with relatively dominant liquid transport at comparatively large (de...... in building materials. Drying and ad-/desorption tests are executed on two building materials, in which moisture contents and moisture potentials are measured simultaneously. These are translated into dynamic retention relations and dynamic storage coefficients, which both distinctly demonstrate that moisture......In relation to moisture storage in porous materials, it is often assumed that the process dynamics do not affect the moisture retention. There is mounting evidence though that this notion is incorrect: various studies demonstrate that the moisture retention is influenced by the (de)saturation rates...

  9. Nanosilica Modification of Elastomer-Modified VARTM Epoxy Resins for Improved Resin and Composite Toughness

    National Research Council Canada - National Science Library

    Robinette, Jason; Bujanda, Andres; DeSchepper, Daniel; Dibelka, Jessica; Costanzo, Philip; Jensen, Robert; McKnight, Steven

    2007-01-01

    Recent publications have reported a synergy between rubber and silica in modified epoxy resins that results in significantly improved fracture toughness without reductions in other material properties...

  10. A novel and facile strategy for highly flame retardant polymer foam composite materials: Transforming silicone resin coating into silica self-extinguishing layer.

    Science.gov (United States)

    Wu, Qian; Zhang, Qian; Zhao, Li; Li, Shi-Neng; Wu, Lian-Bin; Jiang, Jian-Xiong; Tang, Long-Cheng

    2017-08-15

    In this study, a novel strategy was developed to fabricate highly flame retardant polymer foam composite materials coated by synthesized silicone resin (SiR) polymer via a facile dip-coating processing. Applying the SiR polymer coating, the mechanical property and thermal stability of SiR-coated polymer foam (PSiR) composites are greatly enhanced without significantly altering their structure and morphology. The minimum oxygen concentration to support the combustion of foam materials is greatly increased, i.e. from LOI 14.6% for pure foam to LOI 26-29% for the PSiR composites studied. Especially, adjusting pendant group to SiOSi group ratio (R/Si ratio) of SiRs produces highly flame retardant PSiR composites with low smoke toxicity. Cone calorimetry results demonstrate that 44-68% reduction in the peak heat release rate for the PSiR composites containing different R/Si ratios over pure foam is achieved by the presence of appropriate SiR coating. Digital and SEM images of post-burn chars indicate that the SiR polymer coating can be transformed into silica self-extinguishing porous layer as effective inorganic barrier effect, thus preserving the polymer foam structure from fire. Our results show that the SiR dip-coating technique is a promising strategy for producing flame retardant polymer foam composite materials with improved mechanical properties. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Surface hardness evaluation of different composite resin materials: influence of sports and energy drinks immersion after a short-term period

    Science.gov (United States)

    ERDEMİR, Ugur; YİLDİZ, Esra; EREN, Meltem Mert; OZEL, Sevda

    2013-01-01

    Objectives: This study evaluated the effect of sports and energy drinks on the surface hardness of different composite resin restorative materials over a 1-month period. Material and Methods: A total of 168 specimens: Compoglass F, Filtek Z250, Filtek Supreme, and Premise were prepared using a customized cylindrical metal mould and they were divided into six groups (N=42; n=7 per group). For the control groups, the specimens were stored in distilled water for 24 hours at 37º C and the water was renewed daily. For the experimental groups, the specimens were immersed in 5 mL of one of the following test solutions: Powerade, Gatorade, X-IR, Burn, and Red Bull, for two minutes daily for up to a 1-month test period and all the solutions were refreshed daily. Surface hardness was measured using a Vickers hardness measuring instrument at baseline, after 1-week and 1-month. Data were statistically analyzed using Multivariate repeated measure ANOVA and Bonferroni's multiple comparison tests (α=0.05). Results: Multivariate repeated measures ANOVA revealed that there were statistically significant differences in the hardness of the restorative materials in different immersion times (phardness values of the restorative materials was tested using Bonferroni's multiple comparison tests, and it was observed that specimens stored in distilled water demonstrated statistically significant lower mean surface hardness reductions when compared to the specimens immersed in sports and energy drinks after a 1-month evaluation period (phardness of a restorative material depends on the duration of exposure time, and the composition of the material. PMID:23739850

  12. Color stability, water sorption and cytotoxicity of thermoplastic acrylic resin for non metal clasp denture

    OpenAIRE

    Jang, Dae-Eun; Lee, Ji-Young; Jang, Hyun-Seon; Lee, Jang-Jae; Son, Mee-Kyoung

    2015-01-01

    PURPOSE The aim of this study was to compare the color stability, water sorption and cytotoxicity of thermoplastic acrylic resin for the non-metal clasp dentures to those of thermoplastic polyamide and conventional heat-polymerized denture base resins. MATERIALS AND METHODS Three types of denture base resin, which are conventional heat-polymerized acrylic resin (Paladent 20), thermoplastic polyamide resin (Bio Tone), thermoplastic acrylic resin (Acrytone) were used as materials for this study...

  13. Clinical application of removable partial dentures using thermoplastic resin. Part II: Material properties and clinical features of non-metal clasp dentures

    OpenAIRE

    Fueki, Kenji; Ohkubo, Chikahiro; Yatabe, Masaru; Arakawa, Ichiro; Arita, Masahiro; Ino, Satoshi; Kanamori, Toshikazu; Kawai, Yasuhiko; Kawara, Misao; Komiyama, Osamu; Suzuki, Tetsuya; Nagata, Kazuhiro; Hosoki, Maki; Masumi, Shin-ichi; Yamauchi, Mutsuo

    2014-01-01

    This position paper reviews physical and mechanical properties of thermoplastic resin usedfor non-metal clasp dentures, and describes feature of each thermoplastic resin in clinicalapplication of non-metal clasp dentures and complications based on clinical experience ofexpert panels. Since products of thermoplastic resin have great variability in physical andmechanical properties, clinicians should utilize them with careful consideration of thespecific properties of each product. In general, ...

  14. The effects of material loading and flow rate on the disinfection of pathogenic microorganisms using cation resin-silver nanoparticle filter system

    Science.gov (United States)

    Mpenyana-Monyatsi, L.; Mthombeni, N. H.; Onyango, M. S.; Momba, M. N. B.

    2017-08-01

    Waterborne diseases have a negative impact on public health in instances where the available drinking water is of a poor quality. Decentralised systems are needed to provide safe drinking water to rural communities. Therefore, the present study aimed to develop and investigate the point-of-use (POU) water treatment filter packed with resin-coated silver nanoparticles. The filter performance was evaluated by investigating the effects of various bed masses (10 g, 15 g, 20 g) and flow rates (2 mL/min, 5 mL/min, 10 mL/min) by means of breakthrough curves for the removal efficiency of presumptive Escherichia coli, Shigella dysenteriae, Salmonella typhimurium and Vibrio cholerae from spiked groundwater samples. The results revealed that, as the bed mass increases the breakthrough time also increases with regards to all targeted microorganisms. However, when the flow rate increases the breakthrough time decreased. These tests demonstrated that resin-coated silver nanoparticle can be an effective material in removing all targeted microorganisms at 100% removal efficiency before breakthrough points are achieved. Moreover the filter system demonstrated that it is capable of producing 15 L/day of treated water at an operating condition of 10 mL/min flow rate and 15 g bed mass, which is sufficient to provide for seven individuals in the household if they consume 2 L/person/day for drinking purpose. Therefore, the bed mass of the filter system should be increased in order for it to produce sufficient water that will conform to the daily needs of an individual.

  15. Karakteristik Komposit Resin Berkemampuan Mengalir

    Directory of Open Access Journals (Sweden)

    Bambang Irawan

    2015-10-01

    Full Text Available The use of resin composites as posterior restoratives has markedly increased over the past decade. The patients demand for better esthetics, concerns related to possible mercury toxicity from amalgam and improvements in resin composite materials have significantly contributed the popularity of these materials. Early problems related to composites included excessive wear, less of anatomic form, post operative sensitivity, secondary caries and marginal leakage. Marginal adaptation still remains an unavoidable problem for composite restoration, especially at the gingival wall of cervical or Class II restoration. In an attempt to improve marginal sealing, many techniques and lining materials have been designed. To reduce stress generated by polymerization shrinkage, applying and curing of resin composites in layers is often recommended. Using a thick adhesive layer or low-viscosity resin may, due to its elastic properties, serve as a flexible intermediate layer and compensate for the polymerization stress created in resin composite. Flowable composites were created by retaining the same small particle size of traditional hybrid composite but reducing the filler content and allowing the increased resin to reduce the viscosity of the mixture. Flowable composites were introduced in 1996 as liners, fissure sealants and also in tunnel preparations. They have been suggested for Class I, II, III and V cavity restorations, preventive resin restorations and composite, porcelain and amalgam repairing. Their usage as a liner under high filled resins in posterior restorations has been shown to improve the adaptation of composites and effectively achieve clinically acceptable results. This article attempts to give a broad characteristics of different types of flowable composites. 

  16. Heat Transfer Analysis of Encapsulated Phase Change Materials for Thermal Energy Storage

    Science.gov (United States)

    Elmozughi, Ali F.

    Thermal analysis of high temperature phase change materials (PCMs) is conducted. Transient two dimensional heat transfer analysis is performed to investigate high temperature energy storage and retrieval for concentrated solar power applications. The phase change materials are considered are NaNO 3 and the eutectic of MgCl2 and NaCl. Phase change material is encapsulated by a stainless steel in a cylindrical shaped capsule. Energy storage/retrieval into/from various sizes of encapsulated phase change material (EPCM) capsules is simulated for both laminar and turbulent flow conditions of the heat transfer fluid (HTF) by an accurate modeling of the propagating liquid/solid interface in a PCM. Heat transfer inside EPCM capsule and the phase change of PCM are modeled by an enthalpy - porosity method. A two-dimensional cylindrical shaped EPCM capsule or tube is considered in simulations using gas (air) and liquid (Therminol/VP-1) as heat transfer fluids in a cross flow and an axial flow arrangement. The energy storage/retrieval times into/out of the EPCM capsule is dictated by the surface heat transfer of the EPCM for the capsule sizes considered in this study. A single horizontally placed rod in a channel with different blockage ratios for laminar and turbulence flows of HTF is studied in the present study. It is illustrated by the present work that enthalpy-porosity method can be applied to simulate heat transfer at the capsule level and the system level. System level storage module is a thermocline that includes an arrangement of several EPCMs for several megawatts of thermal energy storage (TES) for several hours used in concentrated solar power applications and other industrial thermal systems. Transport phenomena inside the EPCM are modeled accurately by considering a 20% air void and the buoyancy-driven convection in a stainless steel capsule. The effects of the thermal expansion and the volume expansion due to phase change on the energy storage and retrieval

  17. Five-year evaluation of a low-shrinkage Silorane resin composite material: A randomized clinical trial

    DEFF Research Database (Denmark)

    Schmidt, Malene; Dige, Irene; Kirkevang, Lise-Lotte

    2015-01-01

    Objectives The aim of the present study was to investigate the clinical performance of a low-shrinkage silorane-based composite material (Filtek™ Silorane, 3 M-Espe) by comparing it with a methacrylate-based composite material (Ceram•X™, Dentsply DeTrey). Material and methods A number of 72patients...... caries was found in two teeth (Filtek™ Silorane). One tooth showed hypersensitivity (Ceram•X™). Conclusion Restorations of both materials were clinically acceptable after 5 years. This study did not find any advantage of the silorane-based composite over the methacrylate-based composite, which indicates...... that the low-shrinkage of Filtek™ Silorane may not be a determinant factor for clinical success in class II cavities. Clinical relevance This paper is the first to evaluate the 5-year clinical performance of a low-shrinkage composite material....

  18. 76 FR 8774 - Granular Polytetrafluoroethylene Resin From Japan

    Science.gov (United States)

    2011-02-15

    ... From the Federal Register Online via the Government Publishing Office INTERNATIONAL TRADE COMMISSION Granular Polytetrafluoroethylene Resin From Japan AGENCY: United States International Trade... polytetrafluoroethylene resin from Japan would be likely to lead to continuation or recurrence of material injury. On...

  19. Transfer matrix method applied to the parallel assembly of sound absorbing materials.

    Science.gov (United States)

    Verdière, Kévin; Panneton, Raymond; Elkoun, Saïd; Dupont, Thomas; Leclaire, Philippe

    2013-12-01

    The transfer matrix method (TMM) is used conventionally to predict the acoustic properties of laterally infinite homogeneous layers assembled in series to form a multilayer. In this work, a parallel assembly process of transfer matrices is used to model heterogeneous materials such as patchworks, acoustic mosaics, or a collection of acoustic elements in parallel. In this method, it is assumed that each parallel element can be modeled by a 2 × 2 transfer matrix, and no diffusion exists between elements. The resulting transfer matrix of the parallel assembly is also a 2 × 2 matrix that can be assembled in series with the classical TMM. The method is validated by comparison with finite element (FE) simulations and acoustical tube measurements on different parallel/series configurations at normal and oblique incidence. The comparisons are in terms of sound absorption coefficient and transmission loss on experimental and simulated data and published data, notably published data on a parallel array of resonators. From these comparisons, the limitations of the method are discussed. Finally, applications to three-dimensional geometries are studied, where the geometries are discretized as in a FE concept. Compared to FE simulations, the extended TMM yields similar results with a trivial computation time.

  20. A general model for the transfer of radioactive materials in terrestrial food chains

    International Nuclear Information System (INIS)

    Simmonds, J.R.; Linsley, G.S.; Jones, J.A.

    1979-09-01

    A general methodology for modelling the transfer of radionuclides in the food chains to man is described. The models are dynamic in nature so that the long-term time dependence of processes in environmental materials can be represented, for example, the build-up of activity concentrations in soils during continuous deposition from atmosphere. Modules for radionuclide migration are described in well-mixed (cultivated) soil and undisturbed soil (pasture). The methods by which the transfer coefficients used in plant and animal modules are derived are also given. The foodstuffs considered are those derived from green vegetables, grain, and root vegetables together with meat and liver products from the cow and sheep and cow dairy products. The dynamic model permits the time dependence of food chain transfer processes to be represented for different land contamination scenarios; in particular, the model can be adapted to represent behaviour following a single deposit. Using the sensitivity of results to the variation of transfer parameters the model can be used to determine the parts of the food chain where improved data would be most effective in increasing the reliability of radiological assessments; a worked example is given. (author)

  1. Hole-Transfer Dependence on Blend Morphology and Energy Level Alignment in Polymer: ITIC Photovoltaic Materials.

    Science.gov (United States)

    Eastham, Nicholas D; Logsdon, Jenna L; Manley, Eric F; Aldrich, Thomas J; Leonardi, Matthew J; Wang, Gang; Powers-Riggs, Natalia E; Young, Ryan M; Chen, Lin X; Wasielewski, Michael R; Melkonyan, Ferdinand S; Chang, Robert P H; Marks, Tobin J

    2018-01-01

    Bulk-heterojunction organic photovoltaic materials containing nonfullerene acceptors (NFAs) have seen remarkable advances in the past year, finally surpassing fullerenes in performance. Indeed, acceptors based on indacenodithiophene (IDT) have become synonymous with high power conversion efficiencies (PCEs). Nevertheless, NFAs have yet to achieve fill factors (FFs) comparable to those of the highest-performing fullerene-based materials. To address this seeming anomaly, this study examines a high efficiency IDT-based acceptor, ITIC, paired with three donor polymers known to achieve high FFs with fullerenes, PTPD3T, PBTI3T, and PBTSA3T. Excellent PCEs up to 8.43% are achieved from PTPD3T:ITIC blends, reflecting good charge transport, optimal morphology, and efficient ITIC to PTPD3T hole-transfer, as observed by femtosecond transient absorption spectroscopy. Hole-transfer is observed from ITIC to PBTI3T and PBTSA3T, but less efficiently, reflecting measurably inferior morphology and nonoptimal energy level alignment, resulting in PCEs of 5.34% and 4.65%, respectively. This work demonstrates the importance of proper morphology and kinetics of ITIC → donor polymer hole-transfer in boosting the performance of polymer:ITIC photovoltaic bulk heterojunction blends. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Measuring Visual Literacy Skills on Students’ Concept Understanding of Genetic Transfer Material

    Science.gov (United States)

    Fibriana, F.; Pamelasari, S. D.; Aulia, L. S.

    2017-04-01

    Visualization is an important skill for all students majoring in natural sciences. Also, the visual literacy skills (VLS) are essential for Microbiology learning. The lecturer can use the external representations (ERs) to visualize the microorganisms and its microenvironment. One of learning materials which are rather difficult to interpret in microbiology is genetic transfer. In this study, we measure the VLS on students’ concept understanding of genetic transfer material using a simple test. The tests were held before and after the lecture on this topic employing a combination of talking drawing with picture and picture model. The results show that in the beginning, students showed their poor visual literacy. After the lecture, students were able to draw their understanding on the genetic transfer in bacteria. Most students’ visual literacy ability improves in the level of acceptable. In conclusion, the students’ ability was improved in the average amount of conceptual knowledge. This result reveals that some students comprehend in the correct level of ability, meaning that they have a high degree of conceptual (propositional) and visual knowledge.

  3. Transfer Printed P3HT/PCBM Photoactive Layers: From Material Intermixing to Device Characteristics.

    Science.gov (United States)

    Abdellah, Alaa; Falco, Aniello; Schwarzenberger, Ulrich; Scarpa, Giuseppe; Lugli, Paolo

    2016-02-03

    The fabrication of organic electronic devices involving complex stacks of solution-processable functional materials has proven challenging. Significant material intermixing often occurs as a result of cross-solubility and postdeposition treatments, rendering the realization of even the simplest bilayer architectures rather cumbersome. In this study we investigate the feasibility of a dry transfer printing process for producing abrupt bilayer organic photodiodes (OPDs) and the effect of thermal annealing on the integrity of the bilayer. The process involves the transfer of readily deposited thin films of poly(3-hexylthiophene-2,5-diyl) (P3HT) and [6,6]-phenyl C61 butyric acid methyl ester (PCBM) using a polydimethylsiloxane (PDMS) stamp. Fabricated structures are characterized by means of cross-sectional scanning electron microscopy (SEM), UV/vis absorption spectroscopy, and time-of-flight secondary ion mass spectrometry (TOF-SIMS). Joint consideration of all results unveils abrupt interfaces with no thermal treatment applied and significant material intermixing for samples annealed above 100 °C. The role of the thermally assisted intermixing in determining the performance of complete devices is evaluated through the comparison of J-V characteristics and external quantum efficiencies (EQEs) of identical photodiodes subject to different annealing conditions. It is shown that the performance of such devices approaches the one of bulk heterojunction photodiodes upon thermal annealing at 140 °C for 5 min. Our results demonstrate that transfer printing is a reliable and simple process for the realization of functional multilayers, paving the way for organic electronic devices incorporating complex stacks. It further contributes to a fundamental understanding of material composition within photoactive layers by elucidating the process of thermally assisted intermixing.

  4. Parametric Integral Equations Systems Method In Solving Unsteady Heat Transfer Problems For Laser Heated Materials

    Directory of Open Access Journals (Sweden)

    Sawicki Dominik

    2015-09-01

    Full Text Available One of the most popular applications of high power lasers is heating of the surface layer of a material, in order to change its properties. Numerical methods allow an easy and fast way to simulate the heating process inside of the material. The most popular numerical methods FEM and BEM, used to simulate this kind of processes have one fundamental defect, which is the necessity of discretization of the boundary or the domain. An alternative to avoid the mentioned problem are parametric integral equations systems (PIES, which do not require classical discretization of the boundary and the domain while being numerically solved. PIES method was previously used with success to solve steady-state problems, as well as transient heat transfer problems. The purpose of this paper is to test the efficacy of the PIES method with time discretization in solving problem of laser heating of a material, with different pulse shape approximation functions.

  5. Preparation of well-aligned carbon nanotubes by pyrolysis of phenolic resin in anodic alumina pores

    Science.gov (United States)

    Li, Ke-Zhi; Wei, Jian; Li, He-Jun; Zhang, Yu-Lei; Wang, Chuang; Hou, Dang-She

    2007-07-01

    Well-aligned carbon nanotubes (CNTs) of high quality were synthesized by pyrolysis of phenolic resin at 800 °C in anodic alumina oxide (AAO) pores under argon protection. The innocuous source materials and safe operational conditions permit this method to synthesize well-aligned CNTs in large-scale and low cost. The formation mechanism of the synthesized CNTs is also proposed in this work by a series of visual sketches and is proved with obvious evidence. Firstly, phenolic resin nanotubes form in the template pores through the evaporation of solvent. Heat treatment then transfers these tubes into CNTs.

  6. Porous carbon materials for Li-S batteries based on resorcinol-formaldehyde resin with inverse opal structure

    Science.gov (United States)

    Agrawal, Mukesh; Choudhury, Soumyadip; Gruber, Katharina; Simon, Frank; Fischer, Dieter; Albrecht, Victoria; Göbel, Michael; Koller, Stefan; Stamm, Manfred; Ionov, Leonid

    2014-09-01

    This study reports on a novel approach to fabrication of carbon-sulfur composite material and demonstrates its application as cathode for Li-S batteries. Firstly, highly porous carbon material has been prepared by exploiting PMMA colloidal crystal arrays as sacrificial template and subsequently mixing with elemental sulfur at 155 °C. The resulting carbon-sulfur composite cathode material possess very high intrinsic surface area, conductivity and has been found to demonstrate as high as 1600 mAh g-1 capacity in 1st discharge cycle and about 300-400 mAh g-1 in 50th discharge cycle.

  7. Effect of two fluoride varnishes on the color stability of three resin-based restorative materials: an in vitro study.

    Science.gov (United States)

    Tafaroji, Raha; Biria, Mina; Ameri, Farhad; Torabzadeh, Hassan; Qahari, Pasha; Akbarzadeh Baghban, Alireza

    2016-11-01

    The aim of the present study was to evaluate the effect of two fluoride varnishes on color stability of three resin-based restorative materials. Fifty-four discs (14.5 × 1.7 mm) were fabricated from A2 and A3 shades of a compomer (F2000), a flowable composite (Z350), and a hybrid composite (Z250), and incubated at 37°C for 48 h. Dura Shield (colored) and Fluor Protector (colorless) fluoride varnishes were applied onto the discs. The coating was cleaned using a low-speed handpiece and nylon bristle brush after 24 h of storage in distilled water. A second coating was then applied. A control group with no coating was immersed in distilled water and used. The CIE L*a*b* color scale was measured before the treatments and following each cleaning utilizing a spectrophotometer. The colored fluoride varnish exhibited the highest overall color change (∆E) after the first and the second cleaning procedures in all the materials. Among these, the greatest color change was observed in the A3 shade of F2000, followed by the A3 shade of Z-250. The ∆E was less than 3.3 in all groups, and was therefore clinically acceptable. Color changes following the application of fluoride varnishes were found to be clinically acceptable in all groups. © 2015 Wiley Publishing Asia Pty Ltd.

  8. Activation of Magnesium Lignosulfonate and Kraft Lignin: Influence on the Properties of Phenolic Resin-Based Composites for Potential Applications in Abrasive Materials

    Directory of Open Access Journals (Sweden)

    Lukasz Klapiszewski

    2017-06-01

    Full Text Available Magnesium lignosulfonate and kraft lignin were activated by different oxidizing agents for use in phenolic resin composites used for the production of abrasive components. The physicochemical properties of the oxidized materials were analyzed by Fourier transform infrared spectroscopy (FTIR, X-ray photoelectron spectroscopy (XPS, dynamic mechanical-thermal analysis (DMTA and inverse gas chromatography (IGC. The homogeneity of the model abrasive composites containing the studied products was assessed based on observations obtained using a scanning electron microscope (SEM. FTIR and XPS analysis of the oxidized products indicated that the activation process leads mainly to the formation of carbonyl groups. The IGC technique was used to assess changes in the surface energy and the acid–base properties of the studied biopolymers. The changes in the acid–base properties suggest that more groups acting as electron donors appear on the oxidized surface of the materials. DMTA studies showed that the model composites with 5% magnesium lignosulfonate oxidized by H2O2 had the best thermomechanical properties. Based on the results it was possible to propose a hypothetical mechanism of the oxidation of the natural polymers. The use of such oxidized products may improve the thermomechanical properties of abrasive articles.

  9. Bending characteristics of resin concretes

    Directory of Open Access Journals (Sweden)

    Ribeiro Maria Cristina Santos

    2003-01-01

    Full Text Available In this research work the influence of composition and curing conditions in bending strength of polyester and epoxy concrete is analyzed. Various mixtures of resin and aggregates were considered in view of an optimal combination. The Taguchi methodology was applied in order to reduce the number of tests, and in order to evaluate the influence of various parameters in concrete properties. This methodology is very useful for the planning of experiments. Test results, analyzed by this methodology, shown that the most significant factors affecting bending strength properties of resin concretes are the type of resin, resin content and charge content. An optimal formulation leading to a maximum bending strength was achieved in terms of material parameters.

  10. Enhancing heat capacity of colloidal suspension using nanoscale encapsulated phase-change materials for heat transfer.

    Science.gov (United States)

    Hong, Yan; Ding, Shujiang; Wu, Wei; Hu, Jianjun; Voevodin, Andrey A; Gschwender, Lois; Snyder, Ed; Chow, Louis; Su, Ming

    2010-06-01

    This paper describes a new method to enhance the heat-transfer property of a single-phase liquid by adding encapsulated phase-change nanoparticles (nano-PCMs), which absorb thermal energy during solid-liquid phase changes. Silica-encapsulated indium nanoparticles and polymer-encapsulated paraffin (wax) nanoparticles have been made using colloid method, and suspended into poly-alpha-olefin (PAO) and water for potential high- and low-temperature applications, respectively. The shells prevent leakage and agglomeration of molten phase-change materials, and enhance the dielectric properties of indium nanoparticles. The heat-transfer coefficients of PAO containing indium nanoparticles (30% by mass) and water containing paraffin nanoparticles (10% by mass) are 1.6 and 1.75 times higher than those of corresponding single-phase fluids. The structural integrity of encapsulation allows repeated use of such nanoparticles for many cycles in high heat generating devices.

  11. Communications Received from Certain Member States Regarding Guidelines for the Export of Nuclear Material, Equipment and Technology. Nuclear Transfers and Nuclear-Related Dual-Use Transfers

    International Nuclear Information System (INIS)

    1993-04-01

    The Director General has received a Note Verbale dated 5 March 1993 from the Ministry of Foreign Affairs of the Slovak Republic. The purpose of the Note Verbale is to provide information on that Governments' guidelines for Nuclear Transfers and for Transfers of of Nuclear-related Dual-use Equipment, Material and Related Technology. In the light of the wish expressed at the end of each Note Verbale, the text of the Note Verbale is annexed hereto [es

  12. Communications Received from Certain Member States Regarding Guidelines for the Export of Nuclear Material, Equipment and Technology. Nuclear Transfers and Nuclear-Related Dual-Use Transfers

    International Nuclear Information System (INIS)

    1993-04-01

    The Director General has received a Note Ver bale dated 5 March 1993 from the Ministry of Foreign Affairs of the Slovak Republic. The purpose of the Note Ver bale is to provide information on that Governments' guidelines for Nuclear Transfers and for Transfers of of Nuclear-related Dual-use Equipment, Material and Related Technology. In the light of the wish expressed at the end of each Note Ver bale, the text of the Note Ver bale is annexed hereto

  13. Communications Received from Certain Member States Regarding Guidelines for the Export of Nuclear Material, Equipment and Technology. Nuclear Transfers and Nuclear-Related Dual-Use Transfers

    International Nuclear Information System (INIS)

    1993-04-01

    The Director General has received a Note Verbale dated 5 March 1993 from the Ministry of Foreign Affairs of the Slovak Republic. The purpose of the Note Verbale is to provide information on that Governments' guidelines for Nuclear Transfers and for Transfers of of Nuclear-related Dual-use Equipment, Material and Related Technology. In the light of the wish expressed at the end of each Note Verbale, the text of the Note Verbale is annexed hereto [fr

  14. Optimal Composite Materials using NASA Resins or POSS Nanoparticle Modifications for Low Cost Fabrication of Large Composite Aerospace Structures Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Reduced mass composite materials are crucial to the success of aerospace systems, but their adoption is inhibited because they require autoclave consolidation, a...

  15. EDF specifications on nuclear grade resins

    International Nuclear Information System (INIS)

    Mascarenhas, Darren; Gressier, Frederic; Taunier, Stephane; Le-Calvar, Marc; Ranchoux, Gilles; Marteau, Herve; Labed, Veronique

    2012-09-01

    Ion exchange resins are widely used across EDF, especially within the nuclear division for the purification of water. Important applications include primary circuit, secondary circuit and effluent treatment, which require high quality nuclear grade resins to retain the dissolved species, some of which may be radioactive. There is a need for more and more efficient purification in order to decrease worker dose during maintenance but also to decrease volumes of radioactive resin waste. Resin performance is subject to several forms of degradation, including physical, chemical, thermal and radioactive, therefore appropriate resin properties have to be selected to reduce such effects. Work has been done with research institutes, manufacturers and on EDF sites to select these properties, create specifications and to continuously improve on these specifications. An interesting example of research regarding resin performance is the resin degradation under irradiation. Resins used in the CVCS circuit of EDF nuclear power plants are subject to irradiation over their lifetime. A study was carried out on the effects of total integrated doses of 0.1, 1 and 10 MGy on typically used EDF mixed bed resins in a 'mini-CVCS' apparatus to simultaneously test actual primary circuit fluid. The tests confirmed that the resins still perform efficiently after a typical CVCS radiation dose. Certain resins also need additional specifications in order to maintain the integrity of the particular circuits they are used in. Recently, EDF has updated its requirements on these high purity nuclear grade resins, produced generic doctrines for all products and materials used on site which include resins of all grades, and as a result have also updated a guide on recommended resin usage for the French fleet of reactors. An overview of the evolutions will be presented. (authors)

  16. Indirect Wafer Bonding and Epitaxial Transfer of GaSb-Based Materials

    Science.gov (United States)

    Grzesik, M.; Vangala, S. R.; Goodhue, W. D.

    2013-04-01

    Results from a study of indirect wafer bonding and epitaxial transfer of GaSb-based materials are presented. Benzocyclobutene (BCB) was used as a bonding agent to bond GaSb and epitaxial structures lattice matched to GaSb onto Si, GaAs, and sapphire carrier substrates. To better understand sources of stress during the bonding process, which can result in cracking and subsurface damage of the GaSb-based materials, BCB's hardness and reduced elastic modulus were measured at various stages during the curing process. Based on the results of curing experiments, a bonding and epitaxial transfer process for GaSb-based materials was then developed. Following bonding, using an experimentally determined low-stress cure cycle, GaSb substrates were removed from epitaxial layers of InAsSb using a combination of mechanical thinning and polishing followed by selective chemical etching using a hydrofluoric and chromic acid solution. Etch selectivity data are also presented where selectivity greater than 100:1 is achieved for GaSb:InAsSb.

  17. Capillary-Force-Assisted Clean-Stamp Transfer of Two-Dimensional Materials.

    Science.gov (United States)

    Ma, Xuezhi; Liu, Qiushi; Xu, Da; Zhu, Yangzhi; Kim, Sanggon; Cui, Yongtao; Zhong, Lanlan; Liu, Ming

    2017-11-08

    A simple and clean method of transferring two-dimensional (2D) materials plays a critical role in the fabrication of 2D electronics, particularly the heterostructure devices based on the artificial vertical stacking of various 2D crystals. Currently, clean transfer techniques rely on sacrificial layers or bulky crystal flakes (e.g., hexagonal boron nitride) to pick up the 2D materials. Here, we develop a capillary-force-assisted clean-stamp technique that uses a thin layer of evaporative liquid (e.g., water) as an instant glue to increase the adhesion energy between 2D crystals and polydimethylsiloxane (PDMS) for the pick-up step. After the liquid evaporates, the adhesion energy decreases, and the 2D crystal can be released. The thin liquid layer is condensed to the PDMS surface from its vapor phase, which ensures the low contamination level on the 2D materials and largely remains their chemical and electrical properties. Using this method, we prepared graphene-based transistors with low charge-neutral concentration (3 × 10 10 cm -2 ) and high carrier mobility (up to 48 820 cm 2 V -1 s -1 at room temperature) and heterostructure optoelectronics with high operation speed. Finally, a capillary-force model is developed to explain the experiment.

  18. Recent advances in energy transfer in bulk and nanoscale luminescent materials: from spectroscopy to applications.

    Science.gov (United States)

    Liu, Xiaofeng; Qiu, Jianrong

    2015-12-07

    Transfer of energy occurs endlessly in our universe by means of radiation. Compared to energy transfer (ET) in free space, in solid state materials the transfer of energy occurs in a rather confined manner, which is usually mediated by real or virtual particles, including not only photons, but also electrons, phonons, and excitons. In the present review, we discuss the recent advances in optical ET by resonance mediated with photons in solid materials as well as their nanoscale counterparts, with focus on the photoluminescence behavior pertaining to ET between optically active centers, such as rare earth (RE) ions. This review begins with a brief discussion on the classification of optical ET together with an overview of the theoretical formulations and experimental method for the examination of ET. We will then present a comprehensive discussion on the ET in practical systems in which normal photoluminescence, upconversion and quantum cutting resulted from ET involving metal ions, QDs, organic species, 2D materials and plasmonic nanostructures. Diverse ET systems are therefore simply categorized into cases of ion-ion interactions and non-ion interactions. Special attention has been paid to the progress in the manipulation of spatially confined ET in nanostructured systems including core-shell structures, as well as the ET in multiple exciton generation found in QDs and organic molecules, which behave quite similarly to resonance ET between metal ion centers. Afterwards, we will discuss the broad spectrum of applications of ET in the aforementioned systems, including solid state lighting, solar energy utilization, bio-imaging and diagnosis, and sensing. In the closing part, along with a short summary, we discuss further research focus regarding the problems and possible future directions of optical ET in solids.

  19. Accuracy of Implant Position Transfer and Surface Detail Reproduction with Different Impression Materials and Techniques

    Directory of Open Access Journals (Sweden)

    Marzieh Alikhasi

    2016-03-01

    Full Text Available Objectives: The purpose of this study was to compare the accuracy of implant position transfer and surface detail reproduction using two impression techniques and materials.Materials and Methods: A metal model with two implants and three grooves of 0.25, 0.50 and 0.75 mm in depth on the flat superior surface of a die was fabricated. Ten regular-body polyether (PE and 10 regular-body polyvinyl siloxane (PVS impressions with square and conical transfer copings using open tray and closed tray techniques were made for each group. Impressions were poured with type IV stone, and linear and angular displacements of the replica heads were evaluated using a coordinate measuring machine (CMM. Also, accurate reproduction of the grooves was evaluated by a video measuring machine (VMM. These measurements were compared with the measurements calculated on the reference model that served as control, and the data were analyzed with two-way ANOVA and t-test at P= 0.05.Results: There was less linear displacement for PVS and less angular displacement for PE in closed-tray technique, and less linear displacement for PE in open tray technique (P<0.001. Also, the open tray technique showed less angular displacement with the use of PVS impression material. Detail reproduction accuracy was the same in all the groups (P>0.05(.Conclusion: The open tray technique was more accurate using PE, and also both closed tray and open tray techniques had acceptable results with the use of PVS. The choice of impression material and technique made no significant difference in surface detail reproduction.Keywords: Dental Implants; Dental Impression Materials, Dental Impression Technique

  20. Review: Resin Composite Filling

    OpenAIRE

    Desmond Ng; Jimmy C. M. Hsiao; Keith C. T. Tong; Harry Kim; Yanjie Mai; Keith H. S. Chan

    2010-01-01

    The leading cause of oral pain and tooth loss is from caries and their treatment include restoration using amalgam, resin, porcelain and gold, endodontic therapy and extraction. Resin composite restorations have grown popular over the last half a century because it can take shades more similar to enamel. Here, we discuss the history and use of resin, comparison between amalgam and resin, clinical procedures involved and finishing and polishing techniques for resin restoration. Although resin ...

  1. Materials and Physics Challenges for Spin Transfer Torque Magnetic Random Access Memories

    Energy Technology Data Exchange (ETDEWEB)

    Heinonen, O.

    2014-10-05

    Magnetic random access memories utilizing the spin transfer torque effect for writing information are a strong contender for non-volatile memories scalable to the 20 nm node, and perhaps beyond. I will here examine how these devices behave as the device size is scaled down from 70 nm size to 20 nm. As device sizes go below ~50 nm, the size becomes comparable to intrinsic magnetic length scales and the device behavior does not simply scale with size. This has implications for the device design and puts additional constraints on the materials in the device.

  2. Impacts on health and safety from transfer/consolidation of nuclear materials and hazardous chemicals

    International Nuclear Information System (INIS)

    Gallucci, R.H.V.

    1994-11-01

    Environmental restoration plans at the US Department of Energy (USDOE) Hanford Site calls for transfer/consolidation of ''targets/threats,'' namely nuclear materials and hazardous chemicals. Reductions in the health and safety hazards will depend on the plans implemented. Pacific Northwest Laboratory (PNL) estimated these potential impacts, assuming implementation of the current reference plan and employing ongoing risk and safety analyses. The results indicated the potential for ''significant'' reductions in health and safety hazards in the long term (> 25 years) and a potentially ''noteworthy'' reduction in health hazard in the short term (≤ 25 years)

  3. Forced convective heat transfer in supercooled phase-change material suspensions with stochastic crystallization

    Energy Technology Data Exchange (ETDEWEB)

    Kousksou, T.; El Rhafiki, T.; El Omari, K.; Zeraouli, Y.; Le Guer, Y. [Laboratoire de Thermique Energetique et Procedes, Universite de Pau et des Pays de l' Adour (UPPA), Campus Universitaire, 64000 Pau (France)

    2010-12-15

    A model has been developed for the simulation of laminar hydrodynamic and heat transfer characteristics in a horizontal circular tube for a suspension flow with micro-size phase-change material (PCM) particles. The energy equation is formulated by taking into consideration the heat absorption (or release) due to the phase-change process. The heat source or heat generation term in the energy equation is derived from solutions for freezing or melting inside the particles. The supercooling breakdown induced by the stochastic character of the crystallization is taken into account in the modeling with nucleation laws. The solutions were compared to experimental results obtained by different authors. (author)

  4. Epoxy Resins in Electron Microscopy

    Science.gov (United States)

    Finck, Henry

    1960-01-01

    A method of embedding biological specimens in araldite 502 (Ciba) has been developed for materials available in the United States. Araldite-embedded tissues are suitable for electron microscopy, but the cutting qualities of the resin necessitates more than routine attention during microtomy. The rather high viscosity of araldite 502 also seems to be an unnecessary handicap. The less viscous epoxy epon 812 (Shell) produces specimens with improved cutting qualities, and has several features—low shrinkage and absence of specimen damage during cure, minimal compression of sections, relative absence of electron beam-induced section damage, etc.—which recommends it as a routine embedding material. The hardness of the cured resin can be easily adjusted by several methods to suit the materials embedded in it. Several problems and advantages of working with sections of epoxy resins are also discussed. PMID:13822825

  5. Resin Characterization

    Science.gov (United States)

    2015-06-01

    to see plastic deformation of the surface. 8.1.4.3 Density: Density using the Archimedes principle (ASTM D 792). 8.1.4.4 Density as a Function of...the cure and postcure, quickly cool the sample to 0 °C or lower the temperature to quench the reaction, and then ramp the temperature at 5 °C/min to...prepared by pouring 10 g of resin into a 30-mL screw-cap scintillation vial and adding appropriate amounts of initiator, catalyst, and inhibitor

  6. Subsurface degradation of resin-based composites.

    Science.gov (United States)

    Bagheri, Rafat; Tyas, Martin J; Burrow, Michael F

    2007-08-01

    To determine the depth of a degraded subsurface layer produced in dental composites as a result of exposure to lactic acid or NaOH, by observing the penetration of AgNO(3) solution. Specimens were prepared from four resin composites; Point 4 (Kerr), Premise (Kerr), Filtek Supreme (3M/ESPE), Ceram X (Dentsply), and two polyacid-modified resin composites; Dyract (Dentsply) and F2000 (3M/ESPE). The specimens were immersed in distilled water for 1 week, transferred to one of three aqueous media at 60 degrees C for 2 weeks; distilled water, 0.01mol/L lactic acid or 0.1N NaOH, washed and immersed in 50% (w/w) aqueous silver nitrate for 10 days at 60 degrees C and placed in a photodeveloper solution. After reduction of the silver, specimens were embedded in epoxy resin, sectioned and polished, coated with carbon, and examined by backscattered mode scanning electron microscopy. The depth of silver penetration into the degraded area was measured from the SEM micrographs. Energy dispersive analysis X-ray (EDAX) was used to confirm the presence of silver. NaOH produced the greatest depth of degradation and lactic acid the least. Premise showed the greatest depth of silver penetration when subjected to NaOH, and Filtek Supreme the second with peeling of the surface and cracking, whereas F2000 and Point 4 showed the least in NaOH and lactic acid. ANOVA and Tukey's test showed that the depth of silver penetration was material and solution dependent, and the differences were significant for most of the materials (P<0.05).

  7. Measurement of water transfer and swelling stress in the buffer material due to temperature gradient

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, H. [ITC, Tokai, Ibaraki (Japan); Chijimatsu, M.; Fujita, A.

    1999-03-01

    Coefficients concerning the water transfer in the buffer material was obtained by empirically giving a temperature gradient, and the swelling stress was measured when water was soaked in the sample under the uniform temperature and temperature gradient conditions. The distributions of temperature and water in the buffer material empirically given a temperature gradient were measured to deduce water diffusion constant due to the temperature gradient. The diffusion constant was the order of 10{sup -8} cm{sup 2}/s/degC. As a result of a equitemperature soaking test, it was found that the swelling stress of the part where soaktion was slow was greater than that of the part with fast soaking at a stage of non-uniform water distribution. The water soaking quantity to the sample and swelling stress reached a stationary state after 7000 hours and the water distribution in the whole sample was found saturated. (H. Baba)

  8. Modeling granular materials as compressible nonlinear fluids: Heat transfer boundary value problems

    Directory of Open Access Journals (Sweden)

    Mehrdad Massoudi

    2006-01-01

    Full Text Available We discuss three boundary value problems in the flow and heat transfer analysis in flowing granular materials: (i the flow down an inclined plane with radiation effects at the free surface; (ii the natural convection flow between two heated vertical walls; (iii the shearing motion between two horizontal flat plates with heat conduction. It is assumed that the material behaves like a continuum, similar to a compressible nonlinear fluid where the effects of density gradients are incorporated in the stress tensor. For a fully developed flow the equations are simplified to a system of three nonlinear ordinary differential equations. The equations are made dimensionless and a parametric study is performed where the effects of various dimensionless numbers representing the effects of heat conduction, viscous dissipation, radiation, and so forth are presented.

  9. PETI-298 Prepared by Microwave Synthesis: Neat Resin and Composite Properties

    Science.gov (United States)

    Smith, Joseph G.; Connell, John W.; Li, Chao-Jun; Wu, Wei; Criss, Jim M., Jr.

    2004-01-01

    PETI-298 is a high temperature/high performance matrix resin that is processable into composites by resin transfer molding (RTM), resin infusion and vacuum assisted RTM techniques. It is typically synthesized in a polar aprotic solvent from the reaction of an aromatic anhydride and a combination of diamines and endcapped with phenylethynylphthalic anhydride. Microwave synthesis of PETI-298 was investigated as a means to eliminate solvent and decrease reaction time. The monomers were manually mixed and placed in a microwave oven for various times to determine optimum reaction conditions. The synthetic process was subsequently scaled-up to 330g. Three batches were synthesized and combined to give 1 kg of material that was characterized for thermal and rheological properties and compared to PETI-298 prepared by the classic solution based synthetic method. The microwave synthesized PETI-298 was subsequently used to fabricate flat laminates on T650 carbon fabric by RTM. The composite panels were analyzed and mechanical properties determined and compared with those fabricated from PETI-298 prepared by the classic solution method. The microwave synthesis process and characterization of neat resin and carbon fiber reinforced composites fabricated by RTM will be presented. KEY WORDS: Resin Transfer Molding, High Temperature Polymers, Phenylethynyl Terminated Imides, Microwave Synthesis

  10. Effective properties of linear random materials: application to Al/SiC and resin/glass composites

    Science.gov (United States)

    Dumont, Serge; Lebon, Frédéric

    2008-10-01

    Here we present a statistical study on the effective linear properties of random materials, i.e., microstructures which are random lattices described by a stochastic process. The local numerical procedure associated with the homogenization methods used here was based on a wavelet-element method. The resulting numerical results are compared with those obtained using classical theories. A new approach was developed in order to determine the effective properties in cases where the characteristics of the microstructure are not known.

  11. In Situ Carbon Coated LiNi0.5Mn1.5O4 Cathode Material Prepared by Prepolymer of Melamine Formaldehyde Resin Assisted Method

    Directory of Open Access Journals (Sweden)

    Wei Yang

    2016-01-01

    Full Text Available Carbon coated spinel LiNi0.5Mn1.5O4 were prepared by spray-drying using prepolymer of melamine formaldehyde resin (PMF as carbon source of carbon coating layer. The PMF carbon coated LiNi0.5Mn1.5O4 was characterized by XRD, SEM, and other electrochemical measurements. The as-prepared lithium nickel manganese oxide has the cubic face-centered spinel structure with a space group of Fd3m. It showed good electrochemical performance as a cathode material for lithium ion battery. After 100 discharge and charge cycles at 0.5 C rate, the specific discharge capacity of carbon coated LiNi0.5Mn1.5O4 was 130 mAh·g−1, and the corresponding capacity retention was 98.8%. The 100th cycle specific discharge capacity at 10 C rate of carbon coated LiNi0.5Mn1.5O4 was 105.4 mAh·g−1, and even the corresponding capacity retention was 95.2%.

  12. Effect of different palatal vault shapes on the dimensional stability of glass fiber-reinforced heat-polymerized acrylic resin denture base material.

    Science.gov (United States)

    Dalkiz, Mehmet; Arslan, Demet; Tuncdemir, Ali Riza; Bilgin, M Selim; Aykul, Halil

    2012-01-01

    The aim of this study was to determine the effect of different palatal vault shapes on the dimensional stability of a glass fiber reinforced heat polymerized acrylic resin denture base material. Three edentulous maxilla with shallow, deep and medium shaped palatal vaults were selected and elastomeric impressions were obtained. A maxillary cast with four reference points (A, B, C, and D) was prepared to serve as control. Point (A) was marked in the anterior midline of the edentulous ridge in the incisive papillary region, points (B) and (C) were marked in the right and left posterior midlines of the edentulous ridge in the second molar regions, and point (D) was marked in the posterior palatal midline near the fovea palatina media (Figure 2). To determine linear dimensional changes, distances between four reference points (A-B, A-C, A-D and B-C) were initially measured with a metal gauge accurate within 0.1 mm under a binocular stereo light microscope and data (mm) were recorded. No significant difference of interfacial distance was found in sagittal and frontal sections measured 24 h after polymerization and after 30 days of water storage in any of experimental groups (P>.05). Significant difference of linear dimension were found in all experimental groups (Pbases did not affect the magnitude of interfacial gaps between the bases and the stone cast surfaces.

  13. Material Properties of a Tricalcium Silicate-containing, a Mineral Trioxide Aggregate-containing, and an Epoxy Resin-based Root Canal Sealer.

    Science.gov (United States)

    Prüllage, Raquel-Kathrin; Urban, Kent; Schäfer, Edgar; Dammaschke, Till

    2016-12-01

    The aim was to compare the solubility, radiopacity, and setting times of a tricalcium silicate-containing (BioRoot RCS; Septodont, St Maur-des-Fossés, France) and a mineral trioxide aggregate-containing sealer (MTA Fillapex; Angelus, Londrina, Brazil) with an epoxy resin-based sealer (AH Plus; Dentsply DeTrey, Konstanz, Germany). Solubility in distilled water, radiopacity, and setting time were evaluated in accordance with ISO 6876:2012. The solubility was also measured after soaking the materials in phosphate-buffered saline buffer (PBS). All data were analyzed using 1-way analysis of variance and the Student-Newman-Keuls test. After immersion for 1 minute in distilled water, BioRoot RCS was significantly less soluble than AH Plus and MTA Fillapex (P  .05). The final setting time was 324 (±1) minutes for BioRoot RCS and 612 (±4) minutes for AH Plus. The difference was statistically significant (P < .05). MTA Fillapex did not set completely even after 1 week. The solubility and radiopacity of the sealers were in accordance with ISO 6876:2012. PBS decreased the solubility of BioRoot RCS. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  14. In vitro two-body wear of inlay-onlay composite resin restoratives.

    Science.gov (United States)

    Burgoyne, A R; Nicholls, J I; Brudvik, J S

    1991-02-01

    Inlay-onlay composite resin restorations have been introduced to the profession as alternatives to amalgam and direct composite resins. Two-body wear testing was performed on three inlay-onlay resins and one direct composite resins using a machine designed to produce sliding wear. The composite resins were opposed by human enamel, type III gold alloy, and porcelain. Of the investigated materials, the homogeneously microfilled inlay-onlay material showed significantly less wear. The direct composite resin showed significantly the greatest wear. The hybrid inlay-onlay resins showed intermediate wear. The hybrid inlay-onlay resins and the direct composite (small particle, heavily filled) resin created wear tracks in the opposing surfaces while the homogeneous microfill inlay-onlay resin did not. The depth of the observed wear tracks in the opposing surface was sufficiently substantial to warrant further investigation into the wear of materials that oppose composite resin restorations.

  15. Effects of an applied voltage on direct interspecies electron transfer via conductive materials for methane production.

    Science.gov (United States)

    Lee, Jung-Yeol; Park, Jeong-Hoon; Park, Hee-Deung

    2017-10-01

    Direct interspecies electron transfer (DIET) between exoelectrogenic bacteria and methanogenic archaea via conductive materials is reported as an efficient method to produce methane in anaerobic organic waste digestion. A voltage can be applied to the conductive materials to accelerate the DIET between two groups of microorganisms to produce methane. To evaluate this hypothesis, two sets of anaerobic serum bottles with and without applied voltage were used with a pair of graphite rods as conductive materials to facilitate DIET. Initially, the methane production rate was similar between the two sets of serum bottles, and later the serum bottles with an applied voltage of 0.39V showed a 168% higher methane production rate than serum bottles without an applied voltage. In cyclic voltammograms, the characteristic redox peaks for hydrogen and acetate oxidation were identified in the serum bottles with an applied voltage. In the microbial community analyses, hydrogenotrophic methanogens (e.g. Methanobacterium) were observed to be abundant in serum bottles with an applied voltage, while methanogens utilizing carbon dioxide (e.g., Methanosaeta and Methanosarcina) were dominant in serum bottles without an applied voltage. Taken together, the applied voltage on conductive materials might not be effective to promote DIET in methane production. Instead, it appeared to generate a condition for hydrogenotrophic methanogenesis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Ceramics for Molten Materials Containment, Transfer and Handling on the Lunar Surface

    Science.gov (United States)

    Standish, Evan; Stefanescu, Doru M.; Curreri, Peter A.

    2009-01-01

    As part of a project on Molten Materials Transfer and Handling on the Lunar Surface, molten materials containment samples of various ceramics were tested to determine their performance in contact with a melt of lunar regolith simulant. The test temperature was 1600 C with contact times ranging from 0 to 12 hours. Regolith simulant was pressed into cylinders with the approximate dimensions of 1.25 dia x 1.25cm height and then melted on ceramic substrates. The regolith-ceramic interface was examined after processing to determine the melt/ceramic interaction. It was found that the molten regolith wetted all oxide ceramics tested extremely well which resulted in chemical reaction between the materials in each case. Alumina substrates were identified which withstood contact at the operating temperature of a molten regolith electrolysis cell (1600 C) for eight hours with little interaction or deformation. This represents an improvement over alumina grades currently in use and will provide a lifetime adequate for electrolysis experiments lasting 24 hours or more. Two types of non-oxide ceramics were also tested. It was found that they interacted to a limited degree with the melt resulting in little corrosion. These ceramics, Sic and BN, were not wetted as well as the oxides by the melt, and so remain possible materials for molten regolith handling. Tests wing longer holding periods and larger volumes of regolith are necessary to determine the ultimate performance of the tested ceramics.

  17. Comparative evaluation of compressive strength and flexural strength of conventional core materials with nanohybrid composite resin core material an in vitro study.

    Science.gov (United States)

    Jayanthi, Narasimha; Vinod, V

    2013-09-01

    Several dental materials have been used for core build-up procedures. Most of these materials were not specifically developed for this purpose, but as a consequence of their properties, have found application in core build-up procedures. Improvements in composites and the development of nanocomposites have led to their use as a core build up material due to their superior mechanical properties, optical properties and ease of handling. However it is not clear if they have better mechanical properties than the conventional core build up materials like amalgam, GIC and dual cure composite core build up material. The strength of the core material is very important and this study was undertaken to compare the mechanical properties of materials used for direct core foundations. The differences between the compressive strength and flexural strength of Filtek Z350 nanocomposite with conventional core build up materials like Amalgam, Vitremer GIC and Fluorocore were tested. Cylindrical plexi glass split molds of dimension 6 ± 1 mm [height] x4 ± 1 mm [diameter] were used to fabricate 15 samples of each core material for testing the compressive strength and rectangular plexi glass split molds of dimension 25 ± 1 mm [length] x 2 ± 1 mm[height] x2 ± 1 mm [width] used for fabricating samples for flexural strength. The samples were stored a water bath at 250 °C for 24 h before testing. The samples were tested using a Universal Instron testing machine. The results of the study showed that Fluorocore had the highest compressive strength and flexural strength followed by Filtek Z350 [nanocomposite] Amalgam had the least flexural strength and Vitremer GIC had the least compressive strength. Thus flurocore and nanocomposite are stronger than other core build up materials and hence should be preferred over other conventional core build up materials in extensively damaged teeth.

  18. Remote epitaxy through graphene enables two-dimensional material-based layer transfer

    Science.gov (United States)

    Kim, Yunjo; Cruz, Samuel S.; Lee, Kyusang; Alawode, Babatunde O.; Choi, Chanyeol; Song, Yi; Johnson, Jared M.; Heidelberger, Christopher; Kong, Wei; Choi, Shinhyun; Qiao, Kuan; Almansouri, Ibraheem; Fitzgerald, Eugene A.; Kong, Jing; Kolpak, Alexie M.; Hwang, Jinwoo; Kim, Jeehwan

    2017-04-01

    Epitaxy—the growth of a crystalline material on a substrate—is crucial for the semiconductor industry, but is often limited by the need for lattice matching between the two material systems. This strict requirement is relaxed for van der Waals epitaxy, in which epitaxy on layered or two-dimensional (2D) materials is mediated by weak van der Waals interactions, and which also allows facile layer release from 2D surfaces. It has been thought that 2D materials are the only seed layers for van der Waals epitaxy. However, the substrates below 2D materials may still interact with the layers grown during epitaxy (epilayers), as in the case of the so-called wetting transparency documented for graphene. Here we show that the weak van der Waals potential of graphene cannot completely screen the stronger potential field of many substrates, which enables epitaxial growth to occur despite its presence. We use density functional theory calculations to establish that adatoms will experience remote epitaxial registry with a substrate through a substrate-epilayer gap of up to nine ångströms this gap can accommodate a monolayer of graphene. We confirm the predictions with homoepitaxial growth of GaAs(001) on GaAs(001) substrates through monolayer graphene, and show that the approach is also applicable to InP and GaP. The grown single-crystalline films are rapidly released from the graphene-coated substrate and perform as well as conventionally prepared films when incorporated in light-emitting devices. This technique enables any type of semiconductor film to be copied from underlying substrates through 2D materials, and then the resultant epilayer to be rapidly released and transferred to a substrate of interest. This process is particularly attractive in the context of non-silicon electronics and photonics, where the ability to re-use the graphene-coated substrates allows savings on the high cost of non-silicon substrates.

  19. Changes in the surface of four calcium silicate-containing endodontic materials and an epoxy resin-based sealer after a solubility test.

    Science.gov (United States)

    Borges, R P; Sousa-Neto, M D; Versiani, M A; Rached-Júnior, F A; De-Deus, G; Miranda, C E S; Pécora, J D

    2012-05-01

    To compare the changes in the surface structure and elemental distribution, as well as the percentage of ion release, of four calcium silicate-containing endodontic materials with a well-established epoxy resin-based sealer, submitted to a solubility test. Solubility of AH Plus, iRoot SP, MTA Fillapex, Sealapex and MTA-Angelus (MTA-A) was tested according to ANSI/ADA Specification 57. The deionized water used in the solubility test was submitted to atomic absorption spectrophotometry to determine and quantify Ca(2+), Na(+), K(+), Zn(2+), Ni(2+) and Pb(2+) ions release. In addition, the outer and inner surfaces of nonsubmitted and submitted samples of each material to the solubility test were analysed by means of scanning electron microscopy and energy-dispersive spectroscopy (SEM/EDX). Statistical analysis was performed by using one-way anova and Tukey's post hoc tests (α = 0.05). Solubility results, in percentage, sorted in an increasing order were -1.24 ± 0.19 (MTA-A), 0.28 ± 0.08 (AH Plus), 5.65 ± 0.80 (Sealapex), 14.89 ± 0.73 (MTA Fillapex) and 20.64 ± 1.42 (iRoot SP). AH Plus and MTA-A were statistically similar (P > 0.05), but different from the other materials (P filler particles were more distinguishable. EDX analysis displayed high levels of calcium and carbon at the surface of Sealapex, MTA Fillapex and iRoot SP. AH Plus and MTA-A were in accordance with ANSI/ADA's requirements regarding solubility whilst iRoot SP, MTA Fillapex and Sealapex did not fulfil ANSI/ADA's protocols. High levels of Ca(2+) ion release were observed in all materials except AH Plus. SEM/EDX analysis revealed that all samples had morphological changes in both outer and inner surfaces after the solubility test. High levels of calcium and carbon were also observed at the surface of all materials except AH Plus and MTA-A. © 2011 International Endodontic Journal.

  20. Donor–acceptor graphene-based hybrid materials facilitating photo-induced electron-transfer reactions

    Directory of Open Access Journals (Sweden)

    Anastasios Stergiou

    2014-09-01

    Full Text Available Graphene research and in particular the topic of chemical functionalization of graphene has exploded in the last decade. The main aim is to increase the solubility and thereby enhance the processability of the material, which is otherwise insoluble and inapplicable for technological applications when stacked in the form of graphite. To this end, initially, graphite was oxidized under harsh conditions to yield exfoliated graphene oxide sheets that are soluble in aqueous media and amenable to chemical modifications due to the presence of carboxylic acid groups at the edges of the lattice. However, it was obvious that the high-defect framework of graphene oxide cannot be readily utilized in applications that are governed by charge-transfer processes, for example, in solar cells. Alternatively, exfoliated graphene has been applied toward the realization of some donor–acceptor hybrid materials with photo- and/or electro-active components. The main body of research regarding obtaining donor–acceptor hybrid materials based on graphene to facilitate charge-transfer phenomena, which is reviewed here, concerns the incorporation of porphyrins and phthalocyanines onto graphene sheets. Through illustrative schemes, the preparation and most importantly the photophysical properties of such graphene-based ensembles will be described. Important parameters, such as the generation of the charge-separated state upon photoexcitation of the organic electron donor, the lifetimes of the charge-separation and charge-recombination as well as the incident-photon-to-current efficiency value for some donor–acceptor graphene-based hybrids, will be discussed.

  1. Impact of cementitious materials decalcification on transfer properties: application to radioactive waste deep repository

    International Nuclear Information System (INIS)

    Perlot, C.

    2005-09-01

    Cementitious materials have been selected to compose the engineering barrier system (EBS) of the French radioactive waste deep repository, because of concrete physico-chemical properties: the hydrates of the cementitious matrix and the pH of the pore solution contribute to radionuclides retention; furthermore the compactness of these materials limits elements transport. The confinement capacity of the system has to be assessed while a period at least equivalent to waste activity (up to 100.000 years). His durability was sustained by the evolution of transfer properties in accordance with cementitious materials decalcification, alteration that expresses structure long-term behavior. Then, two degradation modes were carried out, taking into account the different physical and chemical solicitations imposed by the host formation. The first mode, a static one, was an accelerated decalcification test using nitrate ammonium solution. It replicates the EBS alteration dues to underground water. Degradation kinetic was estimated by the amount of calcium leached and the measurement of the calcium hydroxide dissolution front. To evaluate the decalcification impact, samples were characterized before and after degradation in term of microstructure (porosity, pores size distribution) and of transfer properties (diffusivity, gas and water permeability). The influence of cement nature (ordinary Portland cement, blended cement) and aggregates type (lime or siliceous) was observed: experiments were repeated on different mortars mixes. On this occasion, an essential reflection on this test metrology was led. The second mode, a dynamical degradation, was performed with an environmental permeameter. It recreates the EBS solicitations ensured during the re-saturation period, distinguished by the hydraulic pressure imposed by the geologic layer and the waste exothermicity. This apparatus, based on triaxial cell functioning, allows applying on samples pressure drop between 2 and 10 MPa and

  2. Immobilization of spent resin with epoxy resin

    International Nuclear Information System (INIS)

    Gultom, O.; Suryanto; Sayogo; Ramdan

    1997-01-01

    immobilization of spent resin using epoxy resin has been conducted. The spent resin was mixtured with epoxy resin in variation of concentration, i.e., 30, 40, 50, 60, 70 weight percent of spent resin. The mixture were pour into the plastic tube, with a diameter of 40 mm and height of 40 mm. The density, compressive strength and leaching rate were respectively measured by quanta chrome, paul weber apparatus and gamma spectrometer. The results showed that the increasing of waste concentration would be decreased the compressive strength, and increased density by immobilized waste. The leaching rate of 137 Cs from waste product was not detected in experiment (author)

  3. 75 FR 67105 - Granular Polytetrafluoroethylene Resin From Italy and Japan

    Science.gov (United States)

    2010-11-01

    ... COMMISSION Granular Polytetrafluoroethylene Resin From Italy and Japan AGENCY: United States International... granular polytetrafluoroethylene resin from Italy and Japan. SUMMARY: The Commission hereby gives notice... polytetrafluoroethylene resin from Italy and Japan would be likely to lead to continuation or recurrence of material...

  4. Treatment of White Spot Lesions with Icon (Resin Infiltration)

    Science.gov (United States)

    2017-03-23

    FROM: 59 MDW/SGVU SUBJECT: Professional Presentation Approval 8 MAR2017 1. Your paper, entitled T reatment of White Spot Lesions with Icon ( Resin ... Resin Infiltration) 6. TITLE OF MATERIAL TO BE PUBLISHED OR PRESENTED: Treatment of White Spot lesions with Icon ( Resin In filtration) 7. FUNDING

  5. 21 CFR 872.3200 - Resin tooth bonding agent.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Resin tooth bonding agent. 872.3200 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3200 Resin tooth bonding agent. (a) Identification. A resin tooth bonding agent is a device material, such as methylmethacrylate, intended to be painted...

  6. 21 CFR 872.3820 - Root canal filling resin.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Root canal filling resin. 872.3820 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3820 Root canal filling resin. (a) Identification. A root canal filling resin is a device composed of material, such as methylmethacrylate, intended...

  7. Effect of placement of calcium sulphate when used for the repair of furcation perforations on the seal produced by a resin-based material.

    Science.gov (United States)

    Zou, L; Liu, J; Yin, S-H; Tan, J; Wang, F-M; Li, W; Xue, J

    2007-02-01

    To evaluate the sealing ability of calcium sulphate when used under composite resin for the repair of furcation perforations having different diameters. Perforations of different diameter were created in the floors of pulp chambers in 60 extracted human molar teeth with either a number 3 (1 mm diameter) or 5 (1.5 mm diameter) round bur. The specimens of each group were divided into four sub-groups which were repaired with composite resin either alone or in combination with calcium sulphate that created an artificial floor (15 teeth group(-1)). Eight teeth without furcation perforations served as negative controls. In the leakage detection device, 1 mol L(-1) glucose solution was forced under a pressure of 1.5 KPa from the crown towards the pulp chamber floor. The concentration of leaked glucose was measured at 1, 2, 4, 7, 10, 15 and 20 days using a glucose oxidase method and the data evaluated using the rank sum test. The specimens with larger perforations repaired with composite resin alone had significantly more leakage (P resin, leakage in smaller perforations was markedly lower than that in larger ones (P resin alone (P > 0.05). Calcium sulphate significantly improved the sealing ability of 1 mm perforations repaired with composite resin but not for 1.5 mm perforations.

  8. Influence of solid phase conductivity and cellular structure on the heat transfer mechanisms of cellular materials: diverse case studies

    Energy Technology Data Exchange (ETDEWEB)

    Solorzano, Eusebio; Rodriguez-Perez, Miguel Angel; Lazaro, Jaime; Saja, Jose Antonio de [Cellular Materials Group (CellMat), Condensed Matter Physics Department, University of Valladolid (Spain)

    2009-10-15

    An analysis on the influence of solid phase thermal conductivity and cellular structure on the heat transfer mechanisms (HTMs) by means of studying diverse case studies combining theoretical and experimental data. The radiation and conduction mechanisms have been analyzed for cellular materials based on insulating and conductive matrixes using similar concepts and models for both types of materials. (Abstract Copyright [2009], Wiley Periodicals, Inc.)

  9. Treatment method for stabilization of radioactive exchange resin

    International Nuclear Information System (INIS)

    Hideo, Oni; Takashi, Miyake; Hitoshi, Miyamoto; Toshio, Funakoshi; Yuzo, Inagaki.

    1988-01-01

    This is a method for eluting radioactive nuclides from a radioactive ion exchange resin in which it has been absorbed. First, the Cs in this resin is extracted using a neutral salt solution which contains Na + . The Cs that has been transferred to the neutral salt solution is absorbed and expelled by inorganic ion exchangers. Then the Co, Fe, Mn and Sr in said resin are eluted using an acidic solution; the Co, Fe, Mn and Sr that have been transferred to the acidic solution are separated from that solution by means of a diffusion dialysis vat. This process is a unique characteristic of this ion exchange resin treatment method. 1 fig

  10. Photosynthesis Revisited: Optimization of Charge and Energy Transfer in Quantum Materials

    Science.gov (United States)

    Gabor, Nathaniel

    2014-03-01

    The integration of new nano- and molecular-scale quantum materials into ultra-efficient energy harvesting devices presents significant scientific challenges. Of the many challenges, the most difficult is achieving high photon-to-electron conversion efficiency while maintaining broadband absorption. Due to exciton effects, devices composed of quantum materials may allow near-unity optical absorption efficiency yet require the choice of precisely one fundamental energy (HOMO-LUMO gap). To maximize absorption, the simplest device would absorb at the peak of the solar spectrum, which spans the visible wavelengths. If the peak of the solar spectrum spans the visible wavelengths, then why are terrestrial plants green? Here, I discuss a physical model of photosynthetic absorption and photoprotection in which the cell utilizes active feedback to optimize charge and energy transfer, thus maximizing stored energy rather than absorption. This model, which addresses the question of terrestrial greenness, is supported by several recent results that have begun to unravel the details of photoprotection in higher plants. More importantly, this model indicates a novel route for the design of next-generation energy harvesting systems based on nano- and molecular-scale quantum materials.

  11. Transfer matrix modeling an