  1. Leaking electricity in domestic appliances

    International Nuclear Information System (INIS)

    Meier, Alan; Rosen, Karen

    1999-01-01

    Many types of home electronic equipment draw electric power when switched off or not performing their principal functions. Standby power use (or ''leaking electricity'') for most appliances ranges from 1 - 20 watts. Even though standby use of each device is small, the combined standby power use of all appliances in a home can easily exceed 50 watts. Leaking electricity is already responsible for 5 to 10 percent of residential electricity use in the United States and over 10 percent in Japan. An increasing number of white goods also have standby power requirements. There is a growing international effort to limit standby power to around one watt per device. New and existing technologies are available to meet this target at little or no extra cost

  2. Electric emissions from electrical appliances

    International Nuclear Information System (INIS)

    Leitgeb, N.; Cech, R.; Schroettner, J.

    2008-01-01

    Electric emissions from electric appliances are frequently considered negligible, and standards consider electric appliances to comply without testing. By investigating 122 household devices of 63 different categories, it could be shown that emitted electric field levels do not justify general disregard. Electric reference values can be exceeded up to 11-fold. By numerical dosimetry with homogeneous human models, induced intra-corporal electric current densities were determined and factors calculated to elevate reference levels to accounting for reduced induction efficiency of inhomogeneous fields. These factors were found not high enough to allow generally concluding on compliance with basic restrictions without testing. Electric appliances usually simultaneously emit both electric and magnetic fields exposing almost the same body region. Since the sum of induced current densities is limited, one field component reduces the available margin for the other. Therefore, superposition of electric current densities induced by either field would merit consideration. (authors)

  3. Determinants of residential electricity consumption: Using smart meter data to examine the effect of climate, building characteristics, appliance stock, and occupants' behavior

    International Nuclear Information System (INIS)

    Kavousian, Amir; Rajagopal, Ram; Fischer, Martin

    2013-01-01

    We propose a method to examine structural and behavioral determinants of residential electricity consumption, by developing separate models for daily maximum (peak) and minimum (idle) consumption. We apply our method on a data set of 1628 households' electricity consumption. The results show that weather, location and floor area are among the most important determinants of residential electricity consumption. In addition to these variables, number of refrigerators and entertainment devices (e.g., VCRs) are among the most important determinants of daily minimum consumption, while number of occupants and high-consumption appliances such as electric water heaters are the most significant determinants of daily maximum consumption. Installing double-pane windows and energy-efficient lights helped to reduce consumption, as did the energy-conscious use of electric heater. Acknowledging climate change as a motivation to save energy showed correlation with lower electricity consumption. Households with individuals over 55 or between 19 and 35 years old recorded lower electricity consumption, while pet owners showed higher consumption. Contrary to some previous studies, we observed no significant correlation between electricity consumption and income level, home ownership, or building age. Some otherwise energy-efficient features such as energy-efficient appliances, programmable thermostats, and insulation were correlated with slight increase in electricity consumption. - Highlights: • Weather, location and floor area are the most important determinants of residential electricity use. • Daily minimum and maximum are explained by different factors. • Number of refrigerators and entertainment devices explain daily minimum the best. • Number of occupants and high-consumption appliances explain daily maximum the best. • Other factors such as energy efficient features and household's socioeconomic status are examined

  4. Real-Time Recognition Non-Intrusive Electrical Appliance Monitoring Algorithm for a Residential Building Energy Management System

    Directory of Open Access Journals (Sweden)

    Kofi Afrifa Agyeman

    2015-08-01

    Full Text Available The concern of energy price hikes and the impact of climate change because of energy generation and usage forms the basis for residential building energy conservation. Existing energy meters do not provide much information about the energy usage of the individual appliance apart from its power rating. The detection of the appliance energy usage will not only help in energy conservation, but also facilitate the demand response (DR market participation as well as being one way of building energy conservation. However, energy usage by individual appliance is quite difficult to estimate. This paper proposes a novel approach: an unsupervised disaggregation method, which is a variant of the hidden Markov model (HMM, to detect an appliance and its operation state based on practicable measurable parameters from the household energy meter. Performing experiments in a practical environment validates our proposed method. Our results show that our model can provide appliance detection and power usage information in a non-intrusive manner, which is ideal for enabling power conservation efforts and participation in the demand response market.

  5. Evaluation of advanced technologies for residential appliances and residential and commercial lighting

    Energy Technology Data Exchange (ETDEWEB)

    Turiel, I.; Atkinson, B.; Boghosian, S.; Chan, P.; Jennings, J.; Lutz, J.; McMahon, J.; Rosenquist, G.

    1995-01-01

    Section 127 of the Energy Policy Act requires that the Department of Energy (DOE) prepare a report to Congress on the potential for the development and commercialization of appliances that substantially exceed the present federal or state efficiency standards. Candidate high-efficiency appliances must meet several criteria including: the potential exists for substantial improvement (beyond the minimum established in law) of the appliance`s energy efficiency; electric, water, or gas utilities are prepared to support and promote the commercialization of such appliances; manufacturers are unlikely to undertake development and commercialization of such appliances on their own, or development and production would be substantially accelerated by support to manufacturers. This report describes options to improve the efficiency of residential appliances, including water heaters, clothes washers and dryers, refrigerator/freezers, dishwashers, space heating and cooling devices, as well as residential and commercial lighting products. Data from this report (particularly Appendix 1)were used to prepare the report to Congress mentioned previously. For the residential sector, national energy savings are calculated using the LBL Residential Energy Model. This model projects the number of households and appliance saturations over time. First, end-use consumption is calculated for a base case where models that only meet the standard replace existing models as these reach the end of their lifetime. Second, models with efficiencies equal to the technology under consideration replace existing models that reach the end of their lifetime. For the commercial sector, the COMMEND model was utilized to project national energy savings from new technologies. In this report, energy savings are shown for the period 1988 to 2015.

  6. Optimal residential smart appliances scheduling considering distribution network constraints

    Directory of Open Access Journals (Sweden)

    Yu-Ree Kim

    2016-01-01

    Full Text Available As smart appliances (SAs are more widely adopted within distribution networks, residential consumers can contribute to electricity market operations with demand response resources and reduce their electricity bill. However, if the schedules of demand response resources are determined only by the economic electricity rate signal, the schedule can be unfeasible due to the distribution network constraints. Furthermore, it is impossible for consumers to understand the complex physical characteristics and reflect them in their everyday behaviors. This paper introduces the concept of load coordinating retailer (LCR that deals with demand responsive appliances to reduce electrical consumption for the given distribution network constraints. The LCR can play the role of both conventional retailer and aggregated demand response provider for residential customers. It determines the optimal schedules for the aggregated neighboring SAs according to their types within each distribution feeder. The optimization algorithms are developed using Mixed Integer Linear Programming, and the distribution network is solved by the Newton–Raphson AC power flow.

  7. Real-time identification of residential appliance events based on power monitoring

    Science.gov (United States)

    Yang, Zhao; Zhu, Zhicheng; Wei, Zhiqiang; Yin, Bo; Wang, Xiuwei

    2018-03-01

    Energy monitoring for specific home appliances has been regarded as the pre-requisite for reducing residential energy consumption. To enhance the accuracy of identifying operation status of household appliances and to keep pace with the development of smart power grid, this paper puts forward the integration of electric current and power data on the basis of existing algorithm. If average power difference of several adjacent cycles varies from the baseline and goes beyond the pre-assigned threshold value, the event will be flagged. Based on MATLAB platform and domestic appliances simulations, the results of tested data and verified algorithm indicate that the power method has accomplished desired results of appliance identification.

  8. Residential electricity demand in Singapore

    International Nuclear Information System (INIS)

    Ang, B.W.; Goh, T.N.; Liu, X.Q.

    1992-01-01

    Residential electricity consumption in Singapore increased at a rate of 8.8% per year between 1972 and 1990. Estimates of the long-run income and price elasticities are 1.0 and -0.35, respectively. The energy-conservation campaigns that have been launched are found to have marginal effects on consumption. A statistical analysis shows that the consumption is sensitive to small changes in climatic variables, particularly the temperature, which is closely linked to the growing diffusion of electric appliances for environmental controls. There has been a temporal increase in the ownership levels of appliances associated with increasing household incomes. However, other factors were involved since the ownership levels would also increase over time after the elimination of the income effect. A large part of the future growth in electricity demand will arise from the growing need for air-conditioning, which will lead to increasingly large seasonal variations in electricity use. (author)

  9. Characterization of electrical appliances in transient state

    Science.gov (United States)

    Wójcik, Augustyn; Winiecki, Wiesław

    2017-08-01

    The article contains the study about electrical appliance characterization on the basis of power grid signals. To represent devices, parameters of current and voltage signals recorded during transient states are used. In this paper only transients occurring as a result of switching on devices are considered. The way of data acquisition performed in specialized measurement setup developed for electricity load monitoring is described. The paper presents the method of transients detection and the method of appliance parameters calculation. Using the set of acquired measurement data and appropriate software the set of parameters for several household appliances operating in different operating conditions was processed. Usefulness of appliances characterization in Non-Intrusive Appliance Load Monitoring System (NIALMS) with the use of proposed method is discussed focusing on obtained results.

  10. Gas-heating alternatives to the residential electric heat pump. Gas Appliance Technology Center 1987 program. Topical report for Work Area 1.1, October 1989-March 1990

    International Nuclear Information System (INIS)

    Haas, C.

    1990-05-01

    The characteristics of electric heat pumps are described. Options are defined and assessed for utilizing gas heating in conjunction with existing residential electric heat pumps. These options include gas heat introduced into the refrigeration circuit, a flue gas-heated tube bank in the air supply duct, and a hot-water-to-air coil in the supply duct. Economics are presented for conversion of a residence's total space and water heating from electric to gas in New York City and Atlanta. Potential marketing strategies are discussed, and potential gas sales volumes from conversions are estimated. The study concludes that the use of gas water heating coupled with a hydronic coil in the supply ductwork from the air handler is the most advantageous option for the gas industry

  11. Electrical field of electrical appliances versus distance: A preliminary analysis

    International Nuclear Information System (INIS)

    Mustafa, Nur Badariah Ahmad; Nordin, Farah Hani; Ismail, Fakaruddin Ali Ahmad; Alkahtani, Ammar Ahmed; Balasubramaniam, Nagaletchumi; Hock, Goh Chin; Shariff, Z A M

    2013-01-01

    Every household electrical appliance that is plugged in emits electric field even if it is not operating. The source where the appliance is plugged into and the components of household electrical appliance contribute to electric field emission. The electric field may cause unknown disturbance to the environment or also affect the human health and the effect might depends on the strength of the electric field emitted by the appliance. This paper will investigate the strength of the electric field emitted by four different electrical appliances using spectrum analyser. The strength will be captured at three different distances; (i) 1m (ii) 2m and (iii) 3m and analysis of the strength of the electrical field is done based on the three different distances. The measurement results show that the strength of the electric field is strongest when it is captured at 1m and the weakest at 3m from the electrical appliance. The results proved that the farther an object is located from the electrical appliance; the less effect the magnetic field has.

  12. Ubiquitous Monitoring of Electrical Household Appliances

    Science.gov (United States)

    Lloret, Jaime; Macías, Elsa; Suárez, Alvaro; Lacuesta, Raquel

    2012-01-01

    The number of appliances at home is increasing continuously, mainly because they make our lives easier. Currently, technology is integrated in all objects of our daily life. TCP/IP let us monitor our home in real time and check ubiquitously if something is happening at home. Bearing in mind this idea, we have developed a low-cost system, which can be used in any type of electrical household appliance that takes information from the appliance and posts the information to the Twitter Social network. Several sensors placed in the household appliances gather the sensed data and send them wired or wirelessly, depending on the case, using small and cheap devices to a gateway located in the home. This gateway takes decisions, based on the received data, and sends notifications to Twitter. We have developed a software application that takes the values and decides when to issue an alarm to the registered users (Twitter friends of our smart home). The performance of our system has been measured taking into account the home network (using IEEE 802.3u and IEEE 802.11g) and the data publishing in Twitter. As a result, we have generated an original product and service for any electrical household appliance, regardless of the model and manufacturer, that helps home users improve their quality of life. The paper also shows that there is no system with the same innovative features like the ones presented in this paper. PMID:23202205

  13. Ubiquitous monitoring of electrical household appliances.

    Science.gov (United States)

    Lloret, Jaime; Macías, Elsa; Suárez, Alvaro; Lacuesta, Raquel

    2012-11-07

    The number of appliances at home is increasing continuously, mainly because they make our lives easier. Currently, technology is integrated in all objects of our daily life. TCP/IP let us monitor our home in real time and check ubiquitously if something is happening at home. Bearing in mind this idea, we have developed a low-cost system, which can be used in any type of electrical household appliance that takes information from the appliance and posts the information to the Twitter Social network. Several sensors placed in the household appliances gather the sensed data and send them wired or wirelessly, depending on the case, using small and cheap devices to a gateway located in the home. This gateway takes decisions, based on the received data, and sends notifications to Twitter. We have developed a software application that takes the values and decides when to issue an alarm to the registered users (Twitter friends of our smart home). The performance of our system has been measured taking into account the home network (using IEEE 802.3u and IEEE 802.11g) and the data publishing in Twitter. As a result, we have generated an original product and service for any electrical household appliance, regardless of the model and manufacturer, that helps home users improve their quality of life. The paper also shows that there is no system with the same innovative features like the ones presented in this paper.

  14. Educational Electrical Appliance Power Meter and Logger

    Science.gov (United States)

    Nunn, John

    2013-01-01

    The principles behind two different designs of inductive power meter are presented. They both make use of the microphone input of a computer which, together with a custom-written program, can record the instantaneous power of a domestic electrical appliance. The device can be built quickly and can be calibrated with reference to a known power…

  15. 14 CFR 25.1365 - Electrical appliances, motors, and transformers.

    Science.gov (United States)

    2010-01-01

    ... Equipment § 25.1365 Electrical appliances, motors, and transformers. (a) Domestic appliances must be... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Electrical appliances, motors, and transformers. 25.1365 Section 25.1365 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF...

  16. Electrical Appliances and other Equipment

    DEFF Research Database (Denmark)

    Nørgaard, Jørgen

    2006-01-01

    After some reflection on the efficiency concept, the paper first outlines how the most important electrical end-use technologies, used in households as well as in many service institutions, can be designed to consume much less energy than they do today. This is based on techno-physical analyses...... combined with some consideration on the future human need for the energy service output from the technologies. On the above basis is suggested one set of energy services, which a family in a cold climate can enjoy from just annually consuming 250 kWh of electricity per person. This is actually sufficient......-use technologies, are here suggested progressive electricity taxes, followed by critical reflections on the use of energy suppliers to promote selling less energy. Finally are suggested how research can be most effective and useful by being more interdisciplinary and less dependent on business interests...

  17. Quebec residential electricity demand: a microeconometric approach

    International Nuclear Information System (INIS)

    Bernard, J.T.; Bolduc, D.; Belanger, D.

    1996-01-01

    An economic analysis of Quebec residential electricity demand was studied by micro-simulation models. These structural models describe all components which lead to decisions upon durable holdings and electric appliance usage. The demand for space and water heating systems was evaluated. Recent price change in favour of energy sources other than electricity were taken into account. Price and income elasticity ratios were found to be low, as expected when estimating short term use. The role played by socio-economic variables on the choice of space-water heating systems and electricity use was also examined. Recent conversions have indicated a trend toward preference by households in favour of natural gas or oil over electricity. 18 refs., 5 tabs., 1 fig

  18. Challenge: Getting Residential Users to Shift Their Electricity Usage Patterns

    DEFF Research Database (Denmark)

    Brewer, Robert S.; Verdezoto, Nervo; Rasmussen, Mia Kruse

    2015-01-01

    electricity use from the less desirable times to more desirable times, including: feedback technology, pricing incentives, smart appliances, and energy storage. Based on our experience in this area, we present three challenges for residential shifting: getting users to understand the concept of shifting...

  19. POSSIBLE ROLE OF INDOOR RADON REDUCTION SYSTEMS IN BACK-DRAFTING RESIDENTIAL COMBUSTION APPLIANCES

    Science.gov (United States)

    The article gives results of a computational sensitivity analysis conducted to identify conditions under which residential active soil depressurization (ASD) systems for indoor radon reduction might contribute to or create back-drafting of natural draft combustion appliances. Par...

  20. Electrical appliance energy consumption control methods and electrical energy consumption systems

    Science.gov (United States)

    Donnelly, Matthew K [Kennewick, WA; Chassin, David P [Pasco, WA; Dagle, Jeffery E [Richland, WA; Kintner-Meyer, Michael [Richland, WA; Winiarski, David W [Kennewick, WA; Pratt, Robert G [Kennewick, WA; Boberly-Bartis, Anne Marie [Alexandria, VA

    2006-03-07

    Electrical appliance energy consumption control methods and electrical energy consumption systems are described. In one aspect, an electrical appliance energy consumption control method includes providing an electrical appliance coupled with a power distribution system, receiving electrical energy within the appliance from the power distribution system, consuming the received electrical energy using a plurality of loads of the appliance, monitoring electrical energy of the power distribution system, and adjusting an amount of consumption of the received electrical energy via one of the loads of the appliance from an initial level of consumption to an other level of consumption different than the initial level of consumption responsive to the monitoring.

  1. Electrical appliance energy consumption control methods and electrical energy consumption systems

    Science.gov (United States)

    Donnelly, Matthew K [Kennewick, WA; Chassin, David P [Pasco, WA; Dagle, Jeffery E [Richland, WA; Kintner-Meyer, Michael [Richland, WA; Winiarski, David W [Kennewick, WA; Pratt, Robert G [Kennewick, WA; Boberly-Bartis, Anne Marie [Alexandria, VA

    2008-09-02

    Electrical appliance energy consumption control methods and electrical energy consumption systems are described. In one aspect, an electrical appliance energy consumption control method includes providing an electrical appliance coupled with a power distribution system, receiving electrical energy within the appliance from the power distribution system, consuming the received electrical energy using a plurality of loads of the appliance, monitoring electrical energy of the power distribution system, and adjusting an amount of consumption of the received electrical energy via one of the loads of the appliance from an initial level of consumption to an other level of consumption different than the initial level of consumption responsive to the monitoring.

  2. Electric household appliances lighting. Synthesis; Electromenager eclairage. Note de synthese

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-09-01

    This study has been realized on 10000 families in order to know the French behavior concerning the electric household appliances and the lighting of their accommodation. The document presents statistically the answers to the questions on the electric household in the accommodation, the choice criteria, the use conditions, the washing temperatures, the nature of the electric household appliances, the microwave ovens, the influence of the energy-label on the appliances and the lighting. (A.L.B.)

  3. Decision-making in electrical appliance use in the home

    International Nuclear Information System (INIS)

    Yamamoto, Yoshihiro; Suzuki, Akihiko; Fuwa, Yasuhiro; Sato, Tomohiro

    2008-01-01

    This paper presents the results of a survey as well as an argument from the viewpoint of behavioral economics with the aim of clarifying how consumers make decisions about electrical appliance use in the home. A survey of consumers showed that most have little awareness of the energy efficiency of appliances, the price of the services produced by electrical appliances, or electricity rates. These findings indicate that price does not function as a signal in electricity consumption through electrical appliance use. Rather, we found that consumer decision-making in electricity consumption is dependent on the characteristics of the particular electrical appliances they use. Additionally, we argue that the payment system for home electricity consumption plays an important role in decision-making, causing biases due to aspects of human psychology discussed here in terms of satisficing and heuristics, payment decoupling, and budgeting. We conclude that decision-making about electrical appliance use and electricity consumption in the home is not always rational and is affected both by the particular characteristics of appliances and the payment system for electricity consumption along with human psychology

  4. Optimal joint scheduling of electrical and thermal appliances in a smart home environment

    International Nuclear Information System (INIS)

    Shirazi, Elham; Zakariazadeh, Alireza; Jadid, Shahram

    2015-01-01

    Highlights: • Thermal appliances are scheduled based on desired temperature and energy prices. • A discomfort index has been introduced within the home energy scheduling model. • Appliances are scheduled based on activity probability and desired options. • Starting probability depends on the social random factor and consumption behavior. - Abstract: With the development of home area network, residents have the opportunity to schedule their power usage in the home by themselves aiming at reducing electricity expenses. Moreover, as renewable energy sources are deployed in home, a home energy management system needs to consider both energy consumption and generation simultaneously to minimize the energy cost. In this paper, a smart home energy management model has been presented in which electrical and thermal appliances are jointly scheduled. The proposed method aims at minimizing the electricity cost of a residential customer by scheduling various type of appliances considering the residents consumption behavior, seasonal probability, social random factor, discomfort index and appliances starting probability functions. In this model, the home central controller receives the electricity price information, environmental factors data as well as the resident desired options in order to optimally schedule appliances including electrical and thermal. The scheduling approach is tested on a typical home including variety of home appliances, a small wind turbine, photovoltaic panel, combined heat and power unit, boiler and electrical and thermal storages over a 24-h period. The results show that the scheduling of different appliances can be reached simultaneously by using the proposed formulation. Moreover, simulation results evidenced that the proposed home energy management model exhibits a lower cost and, therefore, is more economical.

  5. Estimation of Operating Condition of Appliances Using Circuit Current Data on Electric Distribution Boards

    Science.gov (United States)

    Iwafune, Yumiko; Ogimoto, Kazuhiko; Yagita, Yoshie

    The Energy management systems (EMS) on demand sides are expected as a method to enhance the capability of supply and demand balancing of a power system under the anticipated penetration of renewable energy generation such as Photovoltaics (PV). Elucidation of energy consumption structure in a building is one of important elements for realization of EMS and contributes to the extraction of potential energy saving. In this paper, we propose the estimation method of operating condition of household appliances using circuit current data on an electric distribution board. Circuit current data are broken down by their shape using a self-organization map method and aggregated by appliance based on customers' information of appliance possessed. Proposed method is verified using residential energy consumption measurement survey data.

  6. Residential Electricity Consumption in Poland

    Directory of Open Access Journals (Sweden)

    Edyta Ropuszyńska-Surma

    2016-01-01

    Full Text Available Key factors influencing electricity consumption in the residential sector in Poland have been identified. A fixed-effects model was used, which includes time effects, and a set of covariates, based on the model developed by Houthakker et al. This model estimates electricity demand by using lagged values of the dependent variable along with current and lagged values of electricity prices, and other variables that affect electricity demand such as: population, economic growth, income per capita, price of related goods, etc. The model has been identified according to the research results of the authors and those obtained by Bentzen and Engsted. The set of covariates was extended to the lagged electricity price given by a tariff (taken from two years previous to the time of interest and heating degree days index, a very important factor in European Union countries, where the climate is temperate. The authors propose four models of residential electricity demand, for which a confidence interval of 95% has been assumed. Estimation was based on Polish quarterly data for the years 2003-2013. (original abstract

  7. The Pacific Northwest residential consumer: Perceptions and preferences of home heating fuels, major appliances, and appliance fuels

    Energy Technology Data Exchange (ETDEWEB)

    Harkreader, S.A.; Hattrup, M.P.

    1988-09-01

    In 1983 the Bonneville Power Administration contracted with the Pacific Northwest Laboratory (PNL) to conduct an analysis of the marketing environment for Bonneville's conservation activities. Since this baseline residential study, PNL has conducted two follow up market research projects: Phase 2 in 1985, and Phase 3, in 1988. In this report the respondents' perceptions, preferences, and fuel switching possibilities of fuels for home heating and major appliances are examined. To aid in effective target marketing, the report identifies market segments according to consumers' demographics, life-cycle, attitudes, and opinions.

  8. Impacts of Imported Liquefied Natural Gas on Residential Appliance Components: Literature Review

    Energy Technology Data Exchange (ETDEWEB)

    Lekov, Alex; Sturges, Andy; Wong-Parodi, Gabrielle

    2009-12-09

    An increasing share of natural gas supplies distributed to residential appliances in the U.S. may come from liquefied natural gas (LNG) imports. The imported gas will be of a higher Wobbe number than domestic gas, and there is concern that it could produce more pollutant emissions at the point of use. This report will review recently undertaken studies, some of which have observed substantial effects on various appliances when operated on different mixtures of imported LNG. While we will summarize findings of major studies, we will not try to characterize broad effects of LNG, but describe how different components of the appliance itself will be affected by imported LNG. This paper considers how the operation of each major component of the gas appliances may be impacted by a switch to LNG, and how this local impact may affect overall safety, performance and pollutant emissions.

  9. Magnetic fields from electric toothbrushes promote corrosion in orthodontic stainless steel appliances but not in titanium appliances.

    Science.gov (United States)

    Kameda, Takashi; Ohkuma, Kazuo; Oda, Hirotake; Sano, Natsuki; Batbayar, Nomintsetseg; Terashima, Yukari; Sato, Soh; Terada, Kazuto

    2013-01-01

    Electric toothbrushes are widely used, and their electric motors have been reported to produce low-frequency electromagnetic fields that induced electric currents in metallic objects worn by the users. In this study, we showed that electric toothbrushes generated low-frequency magnetic fields (MFs) and induced electric currents in orthodontic appliances in artificial saliva (AS), which accelerated corrosion in stainless steel (SUS) appliances, but not in titanium (Ti) appliances; the corrosion was evaluated by using an inductively coupled plasma-optical emission spectrometer and a three-dimensional laser confocal microscope. The pH of AS used for appliance immersion did not change during or after MF exposure. These results suggested that MF-induced currents from electric toothbrushes could erode SUS appliances, but not Ti appliances, because of their high corrosion potentials. Further studies are required to clarify the mechanisms of metallic corrosion by induced currents in dental fields, which may trigger metal allergies in patients.

  10. Quantifying the Flexibility of Residential Electricity Demand in 2050: a Bottom-Up Approach

    OpenAIRE

    van Stiphout, Arne; Engels, Jonas; Guldentops, Dries; Deconinck, Geert

    2015-01-01

    This work presents a new method to quantify the flexibility of automatic demand response applied to residential electricity demand using price elasticities. A stochastic bottom-up model of flexible electricity demand in 2050 is presented. Three types of flexible devices are implemented: electrical heating, electric vehicles and wet appliances. Each house schedules its flexible demand w.r.t. a varying price signal, in order to minimize electricity cost. Own- and cross-price elasticities are ob...

  11. Energy efficiency to reduce residential electricity and natural gas use under climate change.

    Science.gov (United States)

    Reyna, Janet L; Chester, Mikhail V

    2017-05-15

    Climate change could significantly affect consumer demand for energy in buildings, as changing temperatures may alter heating and cooling loads. Warming climates could also lead to the increased adoption and use of cooling technologies in buildings. We assess residential electricity and natural gas demand in Los Angeles, California under multiple climate change projections and investigate the potential for energy efficiency to offset increased demand. We calibrate residential energy use against metered data, accounting for differences in building materials and appliances. Under temperature increases, we find that without policy intervention, residential electricity demand could increase by as much as 41-87% between 2020 and 2060. However, aggressive policies aimed at upgrading heating/cooling systems and appliances could result in electricity use increases as low as 28%, potentially avoiding the installation of new generation capacity. We therefore recommend aggressive energy efficiency, in combination with low-carbon generation sources, to offset projected increases in residential energy demand.

  12. Reducing Electricity Demand Peaks by Scheduling Home Appliances Usage

    DEFF Research Database (Denmark)

    Rossello Busquet, Ana; Kardaras, Georgios; Iversen, Villy Bæk

    2011-01-01

    Nowadays there is a tendency to consume electricity during the same period of the day leading to demand peaks. Regular energy consumption habits lead to demand peaks at specific temporal intervals, because users consume power at the same time. In order to avoid demand peaks, users’ appliances...... should consume electricity in a more temporarily distributed way. A new methodology to schedule the usage of home appliances is proposed and analyzed in this paper. The main concept behind this approach is the aggregation of home appliances into priority classes and the definition of a maximum power...... consumption limit, which is not allowed to be exceeded during peak hours. The scenario simulated describes a modern household, where the electrical devices are classified in low and high priority groups. The high priority devices are always granted power in order to operate without temporal restrictions...

  13. Modelling residential electricity demand in the GCC countries

    International Nuclear Information System (INIS)

    Atalla, Tarek N.; Hunt, Lester C.

    2016-01-01

    This paper aims at understanding the drivers of residential electricity demand in the Gulf Cooperation Council countries by applying the structural time series model. In addition to the economic variables of GDP and real electricity prices, the model accounts for population, weather, and a stochastic underlying energy demand trend as a proxy for efficiency and human behaviour. The resulting income and price elasticities are informative for policy makers given the paucity of previous estimates for a region with particular political structures and economies subject to large shocks. In particular, the estimates allow for a sound assessment of the impact of energy-related policies suggesting that if policy makers in the region wish to curtail future residential electricity consumption they would need to improve the efficiency of appliances and increase energy using awareness of consumers, possibly by education and marketing campaigns. Moreover, even if prices were raised the impact on curbing residential electricity growth in the region is likely to be very small given the low estimated price elasticities—unless, that is, prices were raised so high that expenditure on electricity becomes such a large proportion of income that the price elasticities increase (in absolute terms). - Highlights: • Residential electricity demand for Bahrain, Kuwait, Oman, and Saudi Arabia • Estimated residential electricity demand relationships using STSM/UEDT approach • LR income and price elasticities from 0.43 to 0.71 and − 0.16 to zero respectively • Impact CDD elasticities from 0.2 to 0.7 • Estimated UEDTs suggest exogenous electricity using behaviour.

  14. Impacts of US federal energy efficiency standards for residential appliances

    International Nuclear Information System (INIS)

    Meyers, S.; McMahon, J.E.; McNeil, M.; Liu, X.

    2003-01-01

    This study estimated energy, environmental, and consumer impacts of US federal residential energy efficiency standards taking effect in the 1988-2007 period. These standards have been the subject of in-depth analyses conducted as part of the US Department of Energy's (DOE's) standards rulemaking process. This study drew on those analyses, but updated key data and developed a common framework and assumptions for all of the products. We estimate that the considered standards will reduce residential primary energy consumption and carbon dioxide (CO 2 ) emissions by 8-9% in 2020 compared to the levels expected without any standards. The standards will save a cumulative total of 26-32 EJ (25-30 quads) by the year 2015, and 63 EJ (60 quads) by 2030. The estimated cumulative net present value of consumer benefit amounts to nearly US$80 billion by 2015, and grows to US$130 billion by 2030. The overall benefit/cost ratio of cumulative consumer impacts in the 1987-2050 period is 2.75:1. The cumulative cost of the DOE's program to establish and implement the standards is in the range of US$200-US$250 million. (author)

  15. Ubiquitous Monitoring of Electrical Household Appliances 

    Directory of Open Access Journals (Sweden)

    Raquel Lacuesta

    2012-11-01

    Full Text Available The number of appliances at home is increasing continuously, mainly because they make our lives easier. Currently, technology is integrated in all objects of our daily life. TCP/IP let us monitor our home in real time and check ubiquitously if something is happening at home. Bearing in mind this idea, we have developed a low-cost system, which can be used in any type of electrical household appliance that takes information from the appliance and posts the information to the Twitter Social network. Several sensors placed in the household appliances gather the sensed data and send them wired or wirelessly, depending on the case, using small and cheap devices to a gateway located in the home. This gateway takes decisions, based on the received data, and sends notifications to Twitter. We have developed a software application that takes the values and decides when to issue an alarm to the registered users (Twitter friends of our smart home. The performance of our system has been measured taking into account the home network (using IEEE 802.3u and IEEE 802.11g and the data publishing in Twitter. As a result, we have generated an original product and service for any electrical household appliance, regardless of the model and manufacturer, that helps home users improve their quality of life. The paper also shows that there is no system with the same innovative features like the ones presented in this paper.

  16. Securing energy efficiency as a high priority. Scenarios for common appliance electricity consumption in Thailand

    Energy Technology Data Exchange (ETDEWEB)

    Foran, T. [Unit for Social and Environmental Research USER, Faculty of Social Sciences, Chiang Mai University, P.O. Box 144, Chiang Mai, 50200 (Thailand); Du Pont, P.T. [International Resources Group and Joint Graduate School of Energy and Environment, Bangkok (Thailand); Parinya, P. [The Joint Graduate School of Energy and Environment, King Mongkut' s University of Technology Thonburi, Bangkok (Thailand); Phumaraphand, N. [Electricity Generating Authority of Thailand, Nonthaburi (Thailand)

    2010-11-15

    Between 1995 and 2008, Thailand's energy efficiency programs produced an estimated total of 8,369 GWh/year energy savings and 1,471 MW avoided peak power. Despite these impressive saving figures, relatively little future scenario analysis is available to policy makers. Before the 2008 global financial crisis, electricity planners forecasted 5-6% long-term increases in demand. We explored options for efficiency improvements in Thailand's residential sector, which consumes more than 20% of Thailand's total electricity consumption of 150 TWh/year. We constructed baseline and efficient scenarios for the period 2006-2026, for air conditioners, refrigerators, fans, rice cookers, and compact fluorescent light bulbs. We drew on an appliance database maintained by Electricity Generating Authority of Thailand's voluntary labeling program. For the five appliances modeled, the efficiency scenario results in total savings of 12% of baseline consumption after 10 years and 29% of baseline after 20 years. Approximately 80% of savings come from more stringent standards for air conditioners, including phasing out unregulated air conditioner sales within 6 years. Shifting appliance efficiency standards to current best-in-market levels within 6 years produces additional savings. We discuss institutional aspects of energy planning in Thailand that thus far have limited the consideration of energy efficiency as a high-priority resource.

  17. Forecasting residential electricity demand in provincial China.

    Science.gov (United States)

    Liao, Hua; Liu, Yanan; Gao, Yixuan; Hao, Yu; Ma, Xiao-Wei; Wang, Kan

    2017-03-01

    In China, more than 80% electricity comes from coal which dominates the CO2 emissions. Residential electricity demand forecasting plays a significant role in electricity infrastructure planning and energy policy designing, but it is challenging to make an accurate forecast for developing countries. This paper forecasts the provincial residential electricity consumption of China in the 13th Five-Year-Plan (2016-2020) period using panel data. To overcome the limitations of widely used predication models with unreliably prior knowledge on function forms, a robust piecewise linear model in reduced form is utilized to capture the non-deterministic relationship between income and residential electricity consumption. The forecast results suggest that the growth rates of developed provinces will slow down, while the less developed will be still in fast growing. The national residential electricity demand will increase at 6.6% annually during 2016-2020, and populous provinces such as Guangdong will be the main contributors to the increments.

  18. Emission factors from residential combustion appliances burning Portuguese biomass fuels.

    Science.gov (United States)

    Fernandes, A P; Alves, C A; Gonçalves, C; Tarelho, L; Pio, C; Schimdl, C; Bauer, H

    2011-11-01

    Smoke from residential wood burning has been identified as a major contributor to air pollution, motivating detailed emission measurements under controlled conditions. A series of experiments were performed to compare the emission levels from two types of wood-stoves to those of fireplaces. Eight types of biomass were burned in the laboratory: wood from seven species of trees grown in the Portuguese forest (Pinus pinaster, Eucalyptus globulus, Quercus suber, Acacia longifolia, Quercus faginea, Olea europaea and Quercus ilex rotundifolia) and briquettes produced from forest biomass waste. Average emission factors were in the ranges 27.5-99.2 g CO kg(-1), 552-1660 g CO(2) kg(-1), 0.66-1.34 g NO kg(-1), and 0.82-4.94 g hydrocarbons kg(-1) of biomass burned (dry basis). Average particle emission factors varied between 1.12 and 20.06 g kg(-1) biomass burned (dry basis), with higher burn rates producing significantly less particle mass per kg wood burned than the low burn rates. Particle mass emission factors from wood-stoves were lower than those from the fireplace. The average emission factors for organic and elemental carbon were in the intervals 0.24-10.1 and 0.18-0.68 g kg(-1) biomass burned (dry basis), respectively. The elemental carbon content of particles emitted from the energy-efficient "chimney type" logwood stove was substantially higher than in the conventional cast iron stove and fireplace, whereas the opposite was observed for the organic carbon fraction. Pinus pinaster, the only softwood species among all, was the biofuel with the lowest emissions of particles, CO, NO and hydrocarbons.

  19. CE APPROVAL IN ELECTRICAL HOUSEHOLD APPLIANCES AND A CASE STUDY

    Directory of Open Access Journals (Sweden)

    Nazmi EKREN

    2009-01-01

    Full Text Available Due to the reason for rapidly developing technology, increasing competition medium, and awareness of the consumers, nowadays, the exigency of production with good quality has gained more and more significance. Certification of the quality and safety of the products to the consumers is compulsory in terms of producers. There are some documents to certify safety of the products. One of them is CE certificate. In this paper, basic information about CE mark is given and CE standards and tests required for electrical household appliances are mentioned. As an application, one of an electrical household appliance, toaster grill is treated and examined. To obtain CE certificate for toaster grill, required tests are made according to EN60335-2-9 and CE certificate is obtained.

  20. Energy Efficiency: The Implementation of Minimum Energy Performance Standard (MEPS Application on Home Appliances for Residential

    Directory of Open Access Journals (Sweden)

    Rahman K.A

    2016-01-01

    Full Text Available Generally, Minimum Energy Performance Standard (MEPS has been widespread across the country especially developed country. However, most consumers do not even know about the MEPS. Without sufficient knowledge, much energy have been wasted before this. The aim of this study is to review the implementation of MEPS of Asia country and to compare electricity consumption of home appliances with star rating and without star rating. In order to fulfil the objectives of the study, the equipment must be chosen correctly and must be learned properly. The home appliances that will be used also need to be chosen so that the comparison between the appliances will be matched correctly. To understand the results, the analysis was done using graphs and table. The purpose of using graph and table is to understand the comparison between appliances more clearly. The results show that home appliances with MEPS is more efficient on energy saving rather than without MEPS. This is the evidence as a method to educate a consumer on energy saving.

  1. Energy Savings Potential and Opportunities for High-Efficiency Electric Motors in Residential and Commercial Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Goetzler, William [Navigant Consulting, Inc., Burlington, MA (United States); Sutherland, Timothy [Navigant Consulting, Inc., Burlington, MA (United States); Reis, Callie [Navigant Consulting, Inc., Burlington, MA (United States)

    2013-12-04

    This report describes the current state of motor technology and estimates opportunities for energy savings through application of more advanced technologies in a variety of residential and commercial end uses. The objectives of this report were to characterize the state and type of motor technologies used in residential and commercial appliances and equipment and to identify opportunities to reduce the energy consumption of electric motor-driven systems in the residential and commercial sectors through the use of advanced motor technologies. After analyzing the technical savings potential offered by motor upgrades and variable speed technologies, recommended actions are presented.

  2. Reducing electricity demand peaks by scheduling home appliances usage

    Energy Technology Data Exchange (ETDEWEB)

    Rossello-Busquet, A.; Kardaras, G.; Baek Iversen, V.; Soler, J.; Dittmann, L.

    2011-05-15

    Nowadays there is a tendency to consume electricity during the same period of the day leading to demand peaks. Regular energy consumption habits lead to demand peaks at specific temporal intervals, because users consume power at the same time. In order to avoid demand peaks, users' appliances should consume electricity in a more temporarily distributed way. A new methodology to schedule the usage of home appliances is proposed and analyzed in this paper. The main concept behind this approach is the aggregation of home appliances into priority classes and the definition of a maximum power consumption limit, which is not allowed to be exceeded during peak hours. The scenario simulated describes a modern household, where the electrical devices are classified in low and high priority groups. The high priority devices are always granted power in order to operate without temporal restrictions. On the contrary, the low priority devices have to pause their operation, when the algorithm dictates it, and resume it in the future. This can become beneficial for both energy companies and users. The electricity suppliers companies will be capable of regulating power generation during demand peaks periods. Moreover, users can be granted lower electricity bill rates for accepting delaying the operation of some of their appliances. In order to analyze this scenario, teletraffic engineering theory, which is used in evaluating the performance of telecommunication networks, is used. A reversible fair scheduling (RFS) algorithm, which was originally developed for telecommunication networks, is applied. The purpose is to analyze how a power consumption limit and priorities for home appliances will affect the demand peak and the users' everyday life. Verification of the effectiveness of the RFS algorithm is done by means of simulation and by using real data for power consumption and operation hours. The defined maximum power limit of 750 and 1000 Watt was not exceeded during

  3. Appliances facilitating everyday life - electricity use derived from daily activities

    Energy Technology Data Exchange (ETDEWEB)

    Ellegaard, Kajsa (Dept of Thematic Studies, Linkoeping Univ. (Sweden)), e-mail: kajsa.ellegard@liu.se; Widen, Joakim (Dept of Engineering Sciences, Uppsala Univ. (Sweden)); Vrotsou, Katerina (Dept of Science and Technology, Linkoeping Univ. (Sweden))

    2011-06-15

    The purpose of this paper is to present how, using a visualization method, electricity use can be derived from the everyday activity patterns of household members. Target groups are, on the one hand, professionals in the energy sector and energy advisors who need more knowledge about household energy use, and, on the other hand, household members wanting to reduce the energy use by revealing their own habits and thereby finding out how changed activity performance may influence electricity use. The focus is on the relation between utilizing electric appliances to perform everyday life activities and the use of electricity. The visualization method is based on the time-geographic approach developed by Haegerstrand and includes a model that estimates appliance electricity use from household members' activities. Focus, in this paper, is put on some basic activities performed to satisfy daily life needs: cooking and use of information, communication and entertainment devices. These activities appear frequently in the everyday life of households, even though not all household members perform them all. The method is applied on a data material comprising time-diaries written by 463 individuals (aged 10 to 85+) in 179 households in different parts of Sweden. The visualization method reveals when and for how long activities that claim electric appliances are performed by which individual(s). It also shows electricity load curves generated from the use of appliances at different levels, such as individual, household and group or population levels. At household level the method can reveal which household members are the main users of electricity, i.e. the division of labour between household members. Thereby it also informs about whom could be approached by energy companies and energy advisors in information campaigns. The main result of the study is that systematic differences in activity patterns in subgroups of a population can be identified (e.g. men and women) but

  4. The Relationship between Residential Electricity Consumption and Income: A Piecewise Linear Model with Panel Data

    Directory of Open Access Journals (Sweden)

    Yanan Liu

    2016-10-01

    Full Text Available There are many uncertainties and risks in residential electricity consumption associated with economic development. Knowledge of the relationship between residential electricity consumption and its key determinant—income—is important to the sustainable development of the electric power industry. Using panel data from 30 provinces for the 1995–2012 period, this study investigates how residential electricity consumption changes as incomes increase in China. Previous studies typically used linear or quadratic double-logarithmic models imposing ex ante restrictions on the indistinct relationship between residential electricity consumption and income. Contrary to those models, we employed a reduced piecewise linear model that is self-adaptive and highly flexible and circumvents the problem of “prior restrictions”. Robust tests of different segment specifications and regression methods are performed to ensure the validity of the research. The results provide strong evidence that the income elasticity was approximately one, and it remained stable throughout the estimation period. The income threshold at which residential electricity consumption automatically remains stable or slows has not been reached. To ensure the sustainable development of the electric power industry, introducing higher energy efficiency standards for electrical appliances and improving income levels are vital. Government should also emphasize electricity conservation in the industrial sector rather than in residential sector.

  5. Estimation of urban residential electricity demand in China using household survey data

    International Nuclear Information System (INIS)

    Zhou, Shaojie; Teng, Fei

    2013-01-01

    This paper uses annual urban household survey data of Sichuan Province from 2007 to 2009 to estimate the income and price elasticities of residential electricity demand, along with the effects of lifestyle-related variables. The empirical results show that in the urban area of Sichuan province, the residential electricity demand is price- and income-inelastic, with price and income elasticities ranging from −0.35 to −0.50 and from 0.14 to 0.33, respectively. Such lifestyle-related variables as demographic variables, dwelling size and holdings of home appliances, are also important determinants of residential electricity demand, especially the latter. These results are robust to a variety of sensitivity tests. The research findings imply that urban residential electricity demand continues to increase with the growth of income. The empirical results have important policy implications for the Multistep Electricity Price, which been adopted in some cities and is expected to be promoted nationwide through the installation of energy-efficient home appliances. - Highlights: • We estimate price and income elasticities in China using household survey data. • The current study is the first such study in China at this level. • Both price and income are inelastic. • Behavior factors have important impact on electricity consumption

  6. Study on Semantic Assets for Smart Appliances Interoperability : D-S3: THIRD INTERIM REPORT

    NARCIS (Netherlands)

    Daniele, L.M.; Hartog, F.T.H. den; Roes, J.B.M.

    2015-01-01

    About two thirds of the energy consumed by buildings originates from the residential sectors and thus household appliances. Household appliances or home appliances are electrical/mechanical machines which accomplish some household functions. Nowadays, appliances are not stand-alone systems anymore.

  7. Study on Semantic Assets for Smart Appliances Interoperability : D-S2: SECOND INTERIM REPORT

    NARCIS (Netherlands)

    Daniele, L.M.; Hartog, F.T.H. den; Roes, J.B.M.

    2014-01-01

    About two thirds of the energy consumed by buildings originates from the residential sectors and thus household appliances. Household appliances or home appliances are electrical/mechanical machines which accomplish some household functions. Nowadays, appliances are not stand-alone systems anymore.

  8. Study on Semantic Assets for Smart Appliances Interoperability : D-S1: FIRST INTERIM REPORT

    NARCIS (Netherlands)

    Hartog, F.T.H. den; Daniele, L.M.; Roes, J.B.M.

    2014-01-01

    About two thirds of the energy consumed by buildings originates from the residential sectors and thus household appliances. Household appliances or home appliances are electrical/mechanical machines which accomplish some household functions. Nowadays, appliances are not stand-alone systems anymore.

  9. Modelling and forecasting Turkish residential electricity demand

    International Nuclear Information System (INIS)

    Dilaver, Zafer; Hunt, Lester C

    2011-01-01

    This research investigates the relationship between Turkish residential electricity consumption, household total final consumption expenditure and residential electricity prices by applying the structural time series model to annual data over the period from 1960 to 2008. Household total final consumption expenditure, real energy prices and an underlying energy demand trend are found to be important drivers of Turkish residential electricity demand with the estimated short run and the long run total final consumption expenditure elasticities being 0.38 and 1.57, respectively, and the estimated short run and long run price elasticities being -0.09 and -0.38, respectively. Moreover, the estimated underlying energy demand trend, (which, as far as is known, has not been investigated before for the Turkish residential sector) should be of some benefit to Turkish decision makers in terms of energy planning. It provides information about the impact of past policies, the influence of technical progress, the impacts of changes in consumer behaviour and the effects of changes in economic structure. Furthermore, based on the estimated equation, and different forecast assumptions, it is predicted that Turkish residential electricity demand will be somewhere between 48 and 80 TWh by 2020 compared to 40 TWh in 2008. - Research highlights: → Estimated short run and long run expenditure elasticities of 0.38 and 1.57, respectively. → Estimated short run and long run price elasticities of -0.09 and -0.38, respectively. → Estimated UEDT has increasing (i.e. energy using) and decreasing (i.e. energy saving) periods. → Predicted Turkish residential electricity demand between 48 and 80 TWh in 2020.

  10. 78 FR 25724 - Petition for Waiver of GE Appliances From the Department of Energy Residential Refrigerator and...

    Science.gov (United States)

    2013-05-02

    ... refrigerators and refrigerator-freezers that are the focus of this notice.\\1\\ Part B includes definitions, test... division of General Electric Co., (``GE'') is a leading manufacturer and marketer of household appliances...

  11. Magnetic emission ranking of electrical appliances. A comprehensive market survey

    International Nuclear Information System (INIS)

    Leitgeb, N.; Cech, R.; Schroettner, J.; Lehofer, P.; Schmidpeter, U.; Rampetsreiter, M.

    2008-01-01

    Over the last decades emissions of magnetic fields from electric appliances have considerably changed. Based on a comprehensive market survey it could be shown that today magnetic emissions are usually characterised by complex frequency spectra while single-frequency emissions have become rare. Therefore, spectral assessment procedures play a critical role. Compared to frequency-weighted equivalent magnetic induction, rms values may underestimate emissions up to two orders of magnitudes. Therefore, rms measurements are not suitable and emission-ranking lists of devices need revision. Surface hot-spot measurements at nominal load conditions and 230 V/50 Hz supply involved 1146 new electrical devices of 166 different categories. High emissions were not rare. Magnetic emissions of devices of 73 different categories exceeded reference levels up to almost two orders of magnitudes above reference levels. Maximum values were higher than reported so far. Magnetic emissions were high enough to make even conformity with existing basic restrictions not self-evident. (authors)

  12. Cost-effectiveness of high-efficiency appliances in the U.S. residential sector: A case study

    International Nuclear Information System (INIS)

    McNeil, Michael A.; Bojda, Nicholas

    2012-01-01

    This paper presents an analysis of the cost-effectiveness of high-efficiency appliances in the U.S. residential sector using cost and efficiency data developed as part of the regulatory process of the U.S. Department of Energy's Appliances and Commercial Equipment Standards Program. These data are presented as a case study in the development of an ‘efficiency technology database’ which can be expanded and published as a resource to other researchers and policy makers seeking scenarios that optimize efficiency policies and forecast their likely impacts on energy demand and greenhouse gas emissions. The use of this data to evaluate cost-effectiveness according to a variety of metrics is demonstrated using the example of one refrigerator–freezer product class. Cost-effectiveness is then evaluated in terms of cost of conserved energy for refrigerators, room air conditioners, water heaters, cooking equipment, central air conditioners and gas furnaces. The resulting potential of cost-effective improvement ranges from 1% to 53% of energy savings, with a typical potential of 15–20%. - Highlights: ► We determined the potential for cost-effective efficiency for residential appliances. ► We cover 6 appliance groups using cost of conserved energy as a metric for cost-effectiveness. ► Data are source from the DOE's Appliance and Commercial Equipment Standards Program. ► Between 15% and 20% additional cost-effective efficiency improvement is possible.

  13. Modeling Residential Electricity Consumption Function in Malaysia: Time Series Approach

    OpenAIRE

    L. L. Ivy-Yap; H. A. Bekhet

    2014-01-01

    As the Malaysian residential electricity consumption continued to increase rapidly, effective energy policies, which address factors affecting residential electricity consumption, is urgently needed. This study attempts to investigate the relationship between residential electricity consumption (EC), real disposable income (Y), price of electricity (Pe) and population (Po) in Malaysia for 1978-2011 period. Unlike previous studies on Malaysia, the current study focuses on the residential secto...

  14. Norwegian residential electricity demand - a microeconomic assessment of the growth from 1976 to 1993

    International Nuclear Information System (INIS)

    Halvorsen, B.; Larsen, B.M.

    2001-01-01

    The Norwegian residential electricity consumption increased by an average of 3% annually during the period 1976-1993. Political signals indicate that the growth in Norwegian residential energy consumption should be reduced, and that it may be necessary to increase energy taxes. Based on data for the sample of households from the annual consumer expenditure survey, we study factors that are of importance explaining the growth in Norwegian residential electricity demand during this period. Nearly half of the growth is due to an increase in the number of households, while the rest reflects an increase in average consumption per household. The increase in average consumption per household is due to an increasing number of households possessing electric household appliances such as dryers and dishwashers, an increase in real disposable household income and in the floor space of dwellings. (author)

  15. Development and evaluation of a new depressurization spillage test for residential gas-fired combustion appliances : final report

    International Nuclear Information System (INIS)

    Edwards, P.

    2005-07-01

    This paper presented a newly developed combustion depressurization spillage test for residential combustion appliances. The test uses carbon dioxide (CO 2 ) that is produced in the fuel combustion process as a tracer gas. The test accurately measures the amount of combustion spillage from residential combustion appliances and their venting systems when they operate at certain levels of depressurization. Seven commonly used gas-fired appliances were used to evaluate the new test as well as the appliances. These included 2 power-vented storage-tank water heaters, 1 mid-efficiency furnace, 2 high-efficiency condensing furnaces, and 2 direct-vent gas fireplaces. Tests were performed for each unit with the test room initially depressurized by 50 Pa compared with the pressure outside the room. If the combustion spillage exceeded 2 per cent, the test was repeated with the room depressurized by 20 Pa, and then by 5 Pa. Each appliance was operated for 5 minutes of burner operation during which time the burner fuel consumption, the concentration of CO 2 and the exhaust fan flow rate were monitored. Measurements were taken for 2 minutes following burner shut off. The amount of CO 2 that was released into the test room from the appliance and its venting system was determined from the measurements and then compared with the amount of CO 2 that would be produced by combustion of the fuel that was consumed during the test. The ratio of the 2 provided a direct measure of the combustion spillage of the appliance and its venting system. The study revealed that 3 products had undetectable levels of combustion spillage, 3 products had low, but measurable combustion spillage, and 1 product had significant combustion spillage. refs., tabs., figs

  16. The possible role of indoor radon reduction systems in back-drafting residential combustion appliances

    International Nuclear Information System (INIS)

    Henschel, D.B.

    1997-01-01

    A computational sensitivity analysis was conducted to identify the conditions under which residential active soil depressurization (ASD) systems for indoor radon reduction might most likely exacerbate or create back-drafting of natural-draft combustion appliances. Parameters varied included: house size; normalized leakage area; exhaust rate of exhaust appliances other than the ASD system; and the amount of house air exhausted by the ASD system. Even with a reasonably conservative set of assumptions, it is predicted that ASD systems should not exacerbate or create back- drafting in most of the U.S. housing stock. Only at normalized leakage areas lower than 3 to 4 cm 2 commercial at 4 Pa) per m 2 of floor area should ASD contribute to back-drafting, even in small houses at high ASD exhaust rates (compared to a mean of over 10 cm 2 /m 2 determined from data on over 12,000 U.S. houses). But on the other hand, even with a more forgiving set of assumptions, it is predicted that ASD systems could contribute to back-drafting in some fraction of the housing stock -houses tighter than about 1 to 2 cm 2 /m 2 - even in large houses at minimal ASD exhaust rates. It is not possible to use parameters such as house size or ASD system flow rate to estimate reliably the risk that an ASD system might contribute to back-drafting in a given house. Spillage/back-draft testing would be needed for essentially all installations. (au) 18 refs

  17. Game-Theoretic Energy Management for Residential Users with Dischargeable Plug-in Electric Vehicles

    Directory of Open Access Journals (Sweden)

    Bingtuan Gao

    2014-11-01

    Full Text Available The plug-in electric vehicle (PEV has attracted more and more attention because of the energy crisis and environmental pollution, which is also the main shiftable load of the residential users’ demand side management (DSM system in the future smart grid (SG. In this paper, we employ game theory to provide an autonomous energy management system among residential users considering selling energy back to the utility company by discharging the PEV’s battery. By assuming all users are equipped with smart meters to execute automatic energy consumption scheduling (ECS and the energy company can adopt adequate pricing tariffs relating to time and level of energy usage, we formulate an energy management game, where the players are the residential users and the strategies are their daily schedules of household appliance use. We will show that the Nash equilibrium of the formulated energy management game can guarantee the global optimization in terms of minimizing the energy costs, where the depreciation cost of PEV’s battery because of discharging and selling energy back is also considered. Simulation results verify that the proposed game-theoretic approach can reduce the total energy cost and individual daily electricity payment. Moreover, since plug-in electric bicycles (PEBs are currently widely used in China, simulation results of residential users owing household appliances and bidirectional energy trading of PEBs are also provided and discussed.

  18. Electricity demand for South Korean residential sector

    International Nuclear Information System (INIS)

    Sa'ad, Suleiman

    2009-01-01

    This study estimates the electricity demand function for the residential sector of South Korea with the aim of examining the effects of improved energy efficiency, structural factors and household lifestyles on electricity consumption. In the study, time series data for the period from 1973 to 2007 is used in a structural time series model to estimate the long-term price and income elasticities and annual growth of underlying energy demand trend (UEDT) at the end of the estimation period. The result shows a long-term income elasticity of 1.33 and a long-term price elasticity of -0.27% with -0.93% as the percentage growth of UEDT at the end of the estimation period. This result suggests that, in order to encourage energy efficiency in the residential sector, the government should complement the market based pricing policies with non-market policies such as minimum energy efficiency standards and public enlightenment.

  19. Electricity demand for South Korean residential sector

    Energy Technology Data Exchange (ETDEWEB)

    Sa' ad, Suleiman [Surrey Energy Economics Centre (SEEC), Department of Economics, University of Surrey, Guildford, Surrey GU2 7XH (United Kingdom)

    2009-12-15

    This study estimates the electricity demand function for the residential sector of South Korea with the aim of examining the effects of improved energy efficiency, structural factors and household lifestyles on electricity consumption. In the study, time series data for the period from 1973 to 2007 is used in a structural time series model to estimate the long-term price and income elasticities and annual growth of underlying energy demand trend (UEDT) at the end of the estimation period. The result shows a long-term income elasticity of 1.33 and a long-term price elasticity of -0.27% with -0.93% as the percentage growth of UEDT at the end of the estimation period. This result suggests that, in order to encourage energy efficiency in the residential sector, the government should complement the market based pricing policies with non-market policies such as minimum energy efficiency standards and public enlightenment. (author)

  20. The Risk of Residential Peak Electricity Demand: A Comparison of Five European Countries

    Directory of Open Access Journals (Sweden)

    Jacopo Torriti

    2017-03-01

    Full Text Available The creation of a Europe-wide electricity market combined with the increased intermittency of supply from renewable sources calls for an investigation into the risk of aggregate peak demand. This paper makes use of a risk model to assess differences in time-use data from residential end-users in five different European electricity markets. Drawing on the Multinational Time-Use Survey database, it assesses risk in relation to the probability of electrical appliance use within households for five European countries. Findings highlight in which countries and for which activities the risk of aggregate peak demand is higher and link smart home solutions (automated load control, dynamic pricing and smart appliances to different levels of peak demand risk.

  1. Modeling of Monthly Residential and Commercial Electricity Consumption Using Nonlinear Seasonal Models—The Case of Hong Kong

    Directory of Open Access Journals (Sweden)

    Wai-Ming To

    2017-06-01

    Full Text Available Accurate modeling and forecasting monthly electricity consumption are the keys to optimizing energy management and planning. This paper examines the seasonal characteristics of electricity consumption in Hong Kong—a subtropical city with 7 million people. Using the data from January 1970 to December 2014, two novel nonlinear seasonal models for electricity consumption in the residential and commercial sectors were obtained. The models show that the city’s monthly residential and commercial electricity consumption patterns have different seasonal variations. Specifically, monthly residential electricity consumption (mainly for appliances and cooling in summer has a quadratic relationship with monthly mean air temperature, while monthly commercial electricity consumption has a linear relationship with monthly mean air temperature. The nonlinear seasonal models were used to predict residential and commercial electricity consumption for the period January 2015–December 2016. The correlations between the predicted and actual values were 0.976 for residential electricity consumption and 0.962 for commercial electricity consumption, respectively. The root mean square percentage errors for the predicted monthly residential and commercial electricity consumption were 7.0% and 6.5%, respectively. The new nonlinear seasonal models can be applied to other subtropical urban areas, and recommendations on the reduction of commercial electricity consumption are given.

  2. Measures for improving the adoption of higher efficiency appliances in Indonesian households: An analysis of lifetime use and decision-making in the purchase of electrical appliances

    International Nuclear Information System (INIS)

    Wijaya, Muhammad Ery; Tezuka, Tetsuo

    2013-01-01

    Highlights: ► We observe human psychosocial variables regarding purchase of electrical appliances. ► Two cities with different cultures are subject of this study – Bandung and Yogyakarta. ► Differences in the lifetime of appliances can be attributed to the cultural. ► Ads and store’s staff have the greatest impact on people’s choice of appliances. ► Adoption of higher-efficiency appliances could be implemented based on each culture. - Abstract: One approach to decreasing electricity consumption is to facilitate the replacement of older appliances with new, higher-efficiency. The objectives of this paper are to compare and analyse the replacement of appliances in two cities of Indonesia – Yogyakarta and Bandung – that are characterised by different cultural backgrounds, ethnicities, and decision-making processes in the household purchase of electrical appliances. A questionnaire survey method was employed to obtain information on behavioural economics and human psychosocial variables such as attitudes, beliefs and perceived benefits regarding the replacement and purchase of electrical appliances. The results show that refrigerators in Yogyakarta have a longer lifetime than in Bandung. However, in Bandung, air conditioners, electric fans, rice cookers, and water pumps have a longer lifetime than in Yogyakarta. These differences in the lifetime of appliances can be attributed to the cultural differences within the two cities that are reflected in the manner in which people use electrical appliances as well as to their lack of knowledge regarding appliance operation. An analysis of the factors influencing the purchase of appliances indicated that people in Yogyakarta show a greater awareness of the benefits of adopting higher-efficiency appliances than do persons in Bandung. The following suggestions could be implemented to improve the strategy of encouraging the adoption of higher-efficiency appliances: (1) in Yogyakarta, energy labelling could be

  3. Implementing peak load reduction algorithms for household electrical appliances

    International Nuclear Information System (INIS)

    Dlamini, Ndumiso G.; Cromieres, Fabien

    2012-01-01

    Considering household appliance automation for reduction of household peak power demand, this study explored aspects of the interaction between household automation technology and human behaviour. Given a programmable household appliance switching system, and user-reported appliance use times, we simulated the load reduction effectiveness of three types of algorithms, which were applied at both the single household level and across all 30 households. All three algorithms effected significant load reductions, while the least-to-highest potential user inconvenience ranking was: coordinating the timing of frequent intermittent loads (algorithm 2); moving period-of-day time-flexible loads to off-peak times (algorithm 1); and applying short-term time delays to avoid high peaks (algorithm 3) (least accommodating). Peak reduction was facilitated by load interruptibility, time of use flexibility and the willingness of users to forgo impulsive appliance use. We conclude that a general factor determining the ability to shift the load due to a particular appliance is the time-buffering between the service delivered and the power demand of an appliance. Time-buffering can be ‘technologically inherent’, due to human habits, or realised by managing user expectations. There are implications for the design of appliances and home automation systems. - Highlights: ► We explored the interaction between appliance automation and human behaviour. ► There is potential for considerable load shifting of household appliances. ► Load shifting for load reduction is eased with increased time buffering. ► Design, human habits and user expectations all influence time buffering. ► Certain automation and appliance design features can facilitate load shifting.

  4. A hybrid society model for simulating residential electricity consumption

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Minjie [School of Electrical Engineering, Beijing Jiaotong University, Beijing (China); State Power Economic Research Institute, Beijing (China); Hu, Zhaoguang [State Power Economic Research Institute, Beijing (China); Wu, Junyong; Zhou, Yuhui [School of Electrical Engineering, Beijing Jiaotong University, Beijing (China)

    2008-12-15

    In this paper, a hybrid social model of econometric model and social influence model is proposed for evaluating the influence of pricing policy and public education policy on residential habit of electricity using in power resources management. And, a hybrid society simulation platform based on the proposed model, called residential electricity consumption multi-agent systems (RECMAS), is designed for simulating residential electricity consumption by multi-agent system. RECMAS is composed of consumer agent, power supplier agent, and policy maker agent. It provides the policy makers with a useful tool to evaluate power price policies and public education campaigns in different scenarios. According to an influenced diffusion mechanism, RECMAS can simulate the residential electricity demand-supply chain and analyze impacts of the factors on residential electricity consumption. Finally, the proposed method is used to simulate urban residential electricity consumption in China. (author)

  5. A hybrid society model for simulating residential electricity consumption

    International Nuclear Information System (INIS)

    Xu, Minjie; Hu, Zhaoguang; Wu, Junyong; Zhou, Yuhui

    2008-01-01

    In this paper, a hybrid social model of econometric model and social influence model is proposed for evaluating the influence of pricing policy and public education policy on residential habit of electricity using in power resources management. And, a hybrid society simulation platform based on the proposed model, called residential electricity consumption multi-agent systems (RECMAS), is designed for simulating residential electricity consumption by multi-agent system. RECMAS is composed of consumer agent, power supplier agent, and policy maker agent. It provides the policy makers with a useful tool to evaluate power price policies and public education campaigns in different scenarios. According to an influenced diffusion mechanism, RECMAS can simulate the residential electricity demand-supply chain and analyze impacts of the factors on residential electricity consumption. Finally, the proposed method is used to simulate urban residential electricity consumption in China. (author)

  6. Effects of socioeconomic factors on household appliance, lighting, and space cooling electricity consumption

    Energy Technology Data Exchange (ETDEWEB)

    Aydinalp, M. [Itron Inc., Boston, MA (United States); Ismet Ugursal, V.; Fung, A.S. [Dalhousie University, Halifax (Canada). Dept. of Mechanical Engineering

    2003-07-01

    Two methods are currently used to model residential energy consumption at the national or regional level: the engineering method and the conditional demand analysis (CDA) method. One of the major difficulties associated with the use of engineering models is the inclusion of consumer behaviour and socioeconomic factors that have significant effects on the residential energy consumption. The CDA method can handle socioeconomic factors if they are included in the model formulation. However, the multicollinearity problem and the need for a very large amount of data make the use of CDA models very difficult. It is shown in this paper that the neural network (NN) method can be used to model the residential energy consumption with the inclusion of socioeconomic factors. The appliances, lighting, and cooling component of the NN based energy consumption model developed for the Canadian residential sector is presented here and the effects of some socioeconomic factors on the residential energy consumption are examined using the model. (author)

  7. Toward semantic interoperability of energy using and producing appliances in residential environments

    NARCIS (Netherlands)

    Hartog, F.T.H. den; Daniele, L.M.; Roes, J.B.M.

    2015-01-01

    About two thirds of the energy consumed in buildings originates household appliances. Nowadays, appliances are often intelligent and networked devices that form complete energy consuming, producing, and managing systems. Reducing energy is therefore a matter of managing and optimizing the energy

  8. The residential demand for electricity in Australia: an application of the bounds testing approach to cointegration

    International Nuclear Information System (INIS)

    Narayan, P.K.; Smyth, R.

    2005-01-01

    This paper reports estimates of the long- and short-run elasticities of residential demand for electricity in Australia using the bounds testing procedure to cointegration, within an autoregressive distributive lag framework. In the long run, we find that income and own price are the most important determinants of residential electricity demand, while temperature is significant some of the time and gas prices are insignificant. Our estimates of long-run income elasticity and price elasticity of demand are consistent with previous studies, although they are towards the lower end of existing estimates. As expected, the short-run elasticities are much smaller than the long-run elasticities, and the coefficients on the error-correction coefficients are small consistent with the fact that in the short-run energy appliances are fixed. (author)

  9. Retailing residential electricity : A concept that makes sense?

    International Nuclear Information System (INIS)

    MacDonald, C.

    2003-07-01

    A heated debate centres around the deregulation of the electricity industry and the retailing of residential electricity. An assessment of the current situation in the industry was provided in this paper to provide a basis for discussion. The experience gained both in Alberta and Texas in residential retail was examined. The main issue of concern is whether residential customers will benefit from deregulation of the electricity sector. The Retail Energy Deregulation (RED) Index provides a benchmark for those jurisdictions considering the residential options. Deregulation has not led to significant benefits to residential customers in most jurisdictions. The electricity industry will always require a central dispatch/market process that will have to designed, governed, regulated, modified regularly. The benefits to residential consumers are not expected for a very long time. Standard market design is an issue that will require attention. refs., 7 figs

  10. Cathalitic burners for residential gas appliances; Bruciatori catalitici di gas naturale per apparecchi domestici

    Energy Technology Data Exchange (ETDEWEB)

    Accornero, R.; Canci, F. [Italgas Spa, Rome (Italy)

    2000-12-01

    The growing interest for the rational use of natural gas as a primary source of energy and for the reduction of pollutant emissions from combustion processes has kindled, in recent years, a widespread interest in studies and experimental investigations on the use of premix burners (either ceramic or metallic) for heat generators in domestic applications. The present paper deals with the R and D activities developed in this field by Italgas, Politecnico di Torino (Dipartimento di Scienza dei Materiali ed Ingegneria Chimica) and Merloni TermoSanitari, (an Italian gas boiler manufacturer). The technology hereby presented aims at reducing the pollutants emissions (CO, NO{sub x}, HC) in a wide range of working regimes of the burner, typical of residential heat appliances. The positive results in a lab scale experimental pilot plant have been in some cases confirmed in experimental runs performed on boiler prototypes suitable for large scale industrial production. Some projects, financially supported by the European Community and involving, beyond the above mentioned partners, also other gas distribution companies, universities, research institutes and burner manufacturers, are currently in progress to further analyse the performance of these burners. [Italian] Il crescente interesse per l'uso razionale del gas naturale quale fonte energetica primaria e quale combustibile a basso impatto ambientale, ha suscitato, nei tempi piu' recenti, un vasto interesse per gli studi e per le ricerche nel settore dei bruciatori di gas di tipo a premiscelazione, siano essi in materiale ceramico che metallico, allo scopo di rendere praticabile la loro applicazione nei generatori di calore di tipo domestico. L'articolo descrive l'attivita' di R e S sviluppata da Italgas, Politecnico di Torino - Dipartimento di Scienza dei Materiali ed Ingegneria Chimica - e da Merloni TermoSanitari. La tecnologia sperimentata e' finalizzata alla riduzione delle emissioni di

  11. Consumer’s Attitude Towards Investments in Residential Energy-Efficient Appliances: How End-User Choices Contribute to Change Future Energy Systems

    DEFF Research Database (Denmark)

    Baldini, Mattia; Trivella, Alessio; Wente, Jordan William Halverson

    2017-01-01

    conventional and environmentally friendly alternatives when purchasing new household electric appliances. This study employs empirical data from a survey conducted by the Danish Energy Agency to model the decision criteria behind Danish consumer investment in energy-efficient labeled appliances. The analysis...... uses logistic regression over a set of socioeconomic, demographic, and behavioral variables to predict purchase propensities. The findings are relevant for policy makers interested in targeting consumers in the appliance market, particularly for a relatively wealthy national context. The study...

  12. Development of the Optimum Operation Scheduling Model of Domestic Electric Appliances for the Supply-Demand Adjustment in a Power System

    Science.gov (United States)

    Ikegami, Takashi; Iwafune, Yumiko; Ogimoto, Kazuhiko

    The high penetration of variable renewable generation such as Photovoltaic (PV) systems will cause the issue of supply-demand imbalance in a whole power system. The activation of the residential power usage, storage and generation by sophisticated scheduling and control using the Home Energy Management System (HEMS) will be needed to balance power supply and demand in the near future. In order to evaluate the applicability of the HEMS as a distributed controller for local and system-wide supply-demand balances, we developed an optimum operation scheduling model of domestic electric appliances using the mixed integer linear programming. Applying this model to several houses with dynamic electricity prices reflecting the power balance of the total power system, it was found that the adequate changes in electricity prices bring about the shift of residential power usages to control the amount of the reverse power flow due to excess PV generation.

  13. Pacific Northwest GridWise™ Testbed Demonstration Projects; Part II. Grid Friendly™ Appliance Project

    Energy Technology Data Exchange (ETDEWEB)

    Hammerstrom, Donald J.; Brous, Jerry; Chassin, David P.; Horst, Gale R.; Kajfasz, Robert; Michie, Preston; Oliver, Terry V.; Carlon, Teresa A.; Eustis, Conrad; Jarvegren, Olof M.; Marek, W.; Munson, Ryan L.; Pratt, Robert G.

    2007-10-01

    Fifty residential electric water heaters and 150 new residential clothes dryers were modified to respond to signals received from underfrequency, load-shedding appliance controllers. Each controller monitored the power-grid voltage signal and requested that electrical load be shed by its appliance whenever electric power-grid frequency fell below 59.95 Hz. The controllers and their appliances were installed and monitored for more than a year at residential sites at three locations in Washington and Oregon. The controllers and their appliances responded reliably to each shallow underfrequency event—an average of one event per day—and shed their loads for the durations of these events. Appliance owners reported that the appliance responses were unnoticed and caused little or no inconvenience for the homes’ occupants.

  14. Empirical Investigations of the Opportunity Limits of Automatic Residential Electric Load Shaping: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Cruickshank, Robert F.; Henze, Gregor P.; Balaji, Rajagopalan; Hodge, Bri-Mathias S.; Florita, Anthony R.

    2017-04-01

    Residential electric load shaping is often modeled as infrequent, utility-initiated, short-duration deferral of peak demand through direct load control. In contrast, modeled herein is the potential for frequent, transactive, intraday, consumer-configurable load shaping for storage-capable thermostatically controlled electric loads (TCLs), including refrigerators, freezers, and hot water heaters. Unique to this study are 28 months of 15-minute-interval observations of usage in 101 homes in the Pacific Northwest United States that specify exact start, duration, and usage patterns of approximately 25 submetered loads per home. The magnitudes of the load shift from voluntarily-participating TCL appliances are aggregated to form hourly upper and lower load-shaping limits for the coordination of electrical generation, transmission, distribution, storage, and demand. Empirical data are statistically analyzed to define metrics that help quantify load-shaping opportunities.

  15. The Sensitivity of Residential Electricity Demand in Indonesia

    Directory of Open Access Journals (Sweden)

    Stranti Nastiti Kusumaningrum

    2018-03-01

    Full Text Available Since 2013, the residential electricity price for High VA (Volt-Ampere households has changed due to changes in pricing policies. This paper analyzes the responsiveness of residential electricity demand to the change in electricity prices and income among two different household groups (Low VA and High VA in 2011 and 2014. Using an electricity consumption model and the Quantile Regression method, the results show that residential electricity demand is price and income inelastic. Income elasticity is lower than price elasticity. Furthermore, the effects on price elasticity also found in the Low VA group, whose rate remained stable. At the same time, evidence proves the impact of the change in pricing policy on income elasticity remains unclear. This result implies that the government has to be more careful in regulating electricity prices for the low VA group, while maintaining economic stability.DOI: 10.15408/sjie.v7i2.6048

  16. Regulating electricity demand peaks for home appliances using reversible fair scheduling

    DEFF Research Database (Denmark)

    Kardaras, Georgios; Rossello Busquet, Ana; Iversen, Villy Bæk

    2010-01-01

    This paper describes a novel methodology for regulating electricity demand peaks for home appliances. To achieve this objective, we will make use of the reversible fair scheduling algorithm originally developed for telecommunication networks. The main concept behind this approach is the aggregati...

  17. “Surprise Gift” Purchases of Small Electric Appliances: A Pilot Study

    NARCIS (Netherlands)

    J. Vanhamme (Joëlle); C.J.P.M. de Bont (Cees)

    2005-01-01

    textabstractUnderstanding decision-making processes for gifts is of strategic importance for companies selling small electrical appliances as gifts account for a large part of their sales. Among all gifts, the ones that are surprising are the most valued by recipients. However, research about

  18. Analysis and modeling of active occupancy of the residential sector in Spain: An indicator of residential electricity consumption

    International Nuclear Information System (INIS)

    López-Rodríguez, M.A.; Santiago, I.; Trillo-Montero, D.; Torriti, J.; Moreno-Munoz, A.

    2013-01-01

    The growing energy consumption in the residential sector represents about 30% of global demand. This calls for Demand Side Management solutions propelling change in behaviors of end consumers, with the aim to reduce overall consumption as well as shift it to periods in which demand is lower and where the cost of generating energy is lower. Demand Side Management solutions require detailed knowledge about the patterns of energy consumption. The profile of electricity demand in the residential sector is highly correlated with the time of active occupancy of the dwellings; therefore in this study the occupancy patterns in Spanish properties was determined using the 2009–2010 Time Use Survey (TUS), conducted by the National Statistical Institute of Spain. The survey identifies three peaks in active occupancy, which coincide with morning, noon and evening. This information has been used to input into a stochastic model which generates active occupancy profiles of dwellings, with the aim to simulate domestic electricity consumption. TUS data were also used to identify which appliance-related activities could be considered for Demand Side Management solutions during the three peaks of occupancy. -- Highlights: •Active occupancy profiles of Spanish dwellings has been obtained and modeled from Time Use Survey data. •Occupancy profiles resulting from the model can be used to model domestic energy consumption. •The presence of three peaks of active occupation was verified, which coincide with morning, noon and evening. •Manual and incentive-based DSM programmes are considered the most suitable for Spanish dwellings. •TV electricity consumption becomes important at aggregate level

  19. Developing a Mixed Neural Network Approach to Forecast the Residential Electricity Consumption Based on Sensor Recorded Data.

    Science.gov (United States)

    Oprea, Simona-Vasilica; Pîrjan, Alexandru; Căruțașu, George; Petroșanu, Dana-Mihaela; Bâra, Adela; Stănică, Justina-Lavinia; Coculescu, Cristina

    2018-05-05

    In this paper, we report a study having as a main goal the obtaining of a method that can provide an accurate forecast of the residential electricity consumption, refining it up to the appliance level, using sensor recorded data, for residential smart homes complexes that use renewable energy sources as a part of their consumed electricity, overcoming the limitations of not having available historical meteorological data and the unwillingness of the contractor to acquire such data periodically in the future accurate short-term forecasts from a specialized institute due to the implied costs. In this purpose, we have developed a mixed artificial neural network (ANN) approach using both non-linear autoregressive with exogenous input (NARX) ANNs and function fitting neural networks (FITNETs). We have used a large dataset containing detailed electricity consumption data recorded by sensors, monitoring a series of individual appliances, while in the NARX case we have also used timestamps datasets as exogenous variables. After having developed and validated the forecasting method, we have compiled it in view of incorporating it into a cloud solution, being delivered to the contractor that can provide it as a service for a monthly fee to both the operators and residential consumers.

  20. 78 FR 28190 - Authorization of Production Activity; Foreign-Trade Subzone 29C; GE Appliances (Electric Water...

    Science.gov (United States)

    2013-05-14

    ... DEPARTMENT OF COMMERCE Foreign-Trade Zones Board [B-7-2013] Authorization of Production Activity; Foreign-Trade Subzone 29C; GE Appliances (Electric Water Heaters); Louisville, Kentucky On January 7, 2013, GE Appliances, operator of Subzone 29C in Louisville, Kentucky, submitted a notification of proposed...

  1. Exploring utility organization electricity generation, residential electricity consumption, and energy efficiency: A climatic approach

    International Nuclear Information System (INIS)

    Craig, Christopher A.; Feng, Song

    2017-01-01

    Highlights: • Study examined impact of electricity fuel sources and consumption on emissions. • 97.2% of variability in emissions explained by coal and residential electricity use. • Increasing cooling degree days significantly related to increased electricity use. • Effectiveness of state-level energy efficiency programs showed mixed results. - Abstract: This study examined the impact of electricity generation by fuel source type and electricity consumption on carbon emissions to assess the role of climatic variability and energy efficiency (EE) in the United States. Despite high levels of greenhouse gas emissions, residential electricity consumption continues to increase in the United States and fossil fuels are the primary fuel source of electricity generation. 97.2% of the variability in carbon emissions in the electricity industry was explained by electricity generation from coal and residential electricity consumption. The relationships between residential electricity consumption, short-term climatic variability, long-term climatic trends, short-term reduction in electricity from EE programs, and long-term trends in EE programs was examined. This is the first study of its nature to examine these relationships across the 48 contiguous United States. Inter-year and long-term trends in cooling degree days, or days above a baseline temperature, were the primary climatic drivers of residential electricity consumption. Cooling degree days increased across the majority of the United States during the study period, and shared a positive relationship with residential electricity consumption when findings were significant. The majority of electricity reduction from EE programs was negatively related to residential electricity consumption where findings were significant. However, the trend across the majority of states was a decrease in electricity reduction from EE while residential electricity consumption increased. States that successfully reduced consumption

  2. Modeling hourly consumption of electricity and district heat in non-residential buildings

    International Nuclear Information System (INIS)

    Kipping, A.; Trømborg, E.

    2017-01-01

    Models for hourly consumption of heat and electricity in different consumer groups on a regional level can yield important data for energy system planning and management. In this study hourly meter data, combined with cross-sectional data derived from the Norwegian energy label database, is used to model hourly consumption of both district heat and electrical energy in office buildings and schools which either use direct electric heating (DEH) or non-electric hydronic heating (OHH). The results of the study show that modeled hourly total energy consumption in buildings with DEH and in buildings with OHH (supplied by district heat) exhibits differences, e.g. due to differences in heat distribution and control systems. In a normal year, in office buildings with OHH the main part of total modeled energy consumption is used for electric appliances, while in schools with OHH the main part is used for heating. In buildings with OHH the share of modeled annual heating energy is higher than in buildings with DEH. Although based on small samples our regression results indicate that the presented method can be used for modeling hourly energy consumption in non-residential buildings, but also that larger samples and additional cross-sectional information could yield improved models and more reliable results. - Highlights: • Schools with district heating (DH) tend to use less night-setback. • DH in office buildings tends to start earlier than direct electric heating (DEH). • In schools with DH the main part of annual energy consumption is used for heating. • In office buildings with DH the main part is used for electric appliances. • Buildings with DH use a larger share of energy for heating than buildings with DEH.

  3. Evolution of residential electricity demand by end-use in Quebec 1979-1989: A conditional demand analysis

    International Nuclear Information System (INIS)

    Lafrance, G.; Perron, D.

    1994-01-01

    Some of the main conclusions are presented from a temporal analysis of three large-scale electricity demand surveys (1979, 1984, and 1989) for the Quebec residential sector. A regression method called conditional demand analysis was used. The study allows a number of conclusions about certain electricity consumption trends by end-uses from 1979 to 1989 by household type and by vintage category. For example, the results indicate that decreasing electricity consumption between 1979 and 1984 for a typical dwelling equipped with electric space heating was mainly related to a large decline in net heating consumption. Overall, the results suggest that some permanent energy savings have been realized by a typical household equipped with an electric heating system due to improvements in standards and changes in customer behavior. These energy savings were partly offset by increased electricity consumption from the purchase of new appliances and an increase in the demand for hot water. 7 refs., 1 fig., 8 tabs

  4. Air conditioning with small power gas appliances

    International Nuclear Information System (INIS)

    Canci, Franco

    1997-01-01

    This article describes research and test activities on small power air conditioning appliances for residential use carried out in the United States, Japan and Europe. The absorption technology aims at the following objectives: to develop appliances requiring reduced maintenance and having a size comparable with electric units of the same output; to reduce production costs and therefore the final prince by adopting special manufacturing technologies such as welded plate exchangers; to obtain appliances which operate both in summer and winter ( as heat pumps), allowing to minimize management and installation costs in southern European climates. The final aim is to offer the customer one appliance only for the following purposes: hot water production for sanitary use, water refrigeration for summer air conditioning, hot water production production for winter heating. This kind of appliance should have management and maintenance costs similar to current individual boilers

  5. Energy use and appliance ownership in Ireland

    International Nuclear Information System (INIS)

    Leahy, Eimear; Lyons, Sean

    2010-01-01

    This paper examines household energy use and appliance ownership in Ireland. Logit regression analyses on a large micro-dataset reveal how household characteristics can help explain the ownership of energy using appliances. Using OLS regression models, we explore the factors affecting residential energy demand conditional on appliance ownership. Results suggest that the methods of space and water heating employed by a household are even more important than electrical appliances in explaining domestic energy usage. However, the stock of appliances must be included in such models so that results will not be biased. The methods employed in this paper can be easily adopted for studies of household energy use in other countries where household expenditure survey data are available.

  6. Estimating elasticity for residential electricity demand in China.

    Science.gov (United States)

    Shi, G; Zheng, X; Song, F

    2012-01-01

    Residential demand for electricity is estimated for China using a unique household level dataset. Household electricity demand is specified as a function of local electricity price, household income, and a number of social-economic variables at household level. We find that the residential demand for electricity responds rather sensitively to its own price in China, which implies that there is significant potential to use the price instrument to conserve electricity consumption. Electricity elasticities across different heterogeneous household groups (e.g., rich versus poor and rural versus urban) are also estimated. The results show that the high income group is more price elastic than the low income group, while rural families are more price elastic than urban families. These results have important policy implications for designing an increasing block tariff.

  7. Recycling of electric appliances. Utilization of the new EU regulation; Recycling von Elektrogeraeten. Nutzen der neuen EU-Richtlinie

    Energy Technology Data Exchange (ETDEWEB)

    Friege, Henning [Awista GmbH, Duesseldorf (Germany)

    2012-10-15

    In the light of a shortage of resources the recycling of secondary raw materials and especially of metals from electric appliances is increasingly gaining importance. If one is to believe the announcements, everything is regulated in the best way. But when one considers closer the data from the recycling of resources and especially the non-ferric (NF) metals from electric and electronic appliances, this still is not a success story - we ought to write it.

  8. Techno-economic analysis of household and community energy storage for residential prosumers with smart appliances

    NARCIS (Netherlands)

    van der Stelt, Sander; Alskaif, T.A.|info:eu-repo/dai/nl/411176455; van Sark, W.G.J.H.M.|info:eu-repo/dai/nl/074628526

    2018-01-01

    The emergence of Decentralized Energy Resources (DERs) and rising electricity demand are known to cause grid instability. Additionally, recent policy developments indicate a decreased tariff in the future for electricity sold to the grid by households with DERs. Energy Storage Systems (ESS) combined

  9. Energy Efficiency of Electrical Appliances - Effects of Instruments and Measures; Energieeffizienz bei Elektrogeraeten

    Energy Technology Data Exchange (ETDEWEB)

    Brunner, C.U.; Bush, E.; Gasser, S.; Lingenhel, S.; Nipkow, J.

    2001-07-01

    This comprehensive report for the Swiss Federal Office of Energy presents the results of an analysis made of the market for electrical appliances in Switzerland with the aim of understanding the instruments and measures needed to improve energy efficiency better. The paper reports on reviews made of previous studies that were made in Switzerland and Germany and on interviews made with important persons and institutions in this field. Eight basic findings are listed concerning market expansion, technical progress, user behaviour, efficiency, possibilities for intervention, market forces, efficient appliances as a niche market and the competence lacking in the energy-efficiency area. Twelve basic points to be considered in the implementation of an energy-efficiency strategy are discussed and a list of requirements to be fulfilled by politics is presented. The results of the analysis for various sectors and the recommendations made for an implementation organisation are presented in detail. The report is concluded with a extract from the data base on the energy consumption of electrical appliances.

  10. The UK-DALE dataset, domestic appliance-level electricity demand and whole-house demand from five UK homes

    Science.gov (United States)

    Kelly, Jack; Knottenbelt, William

    2015-03-01

    Many countries are rolling out smart electricity meters. These measure a home’s total power demand. However, research into consumer behaviour suggests that consumers are best able to improve their energy efficiency when provided with itemised, appliance-by-appliance consumption information. Energy disaggregation is a computational technique for estimating appliance-by-appliance energy consumption from a whole-house meter signal. To conduct research on disaggregation algorithms, researchers require data describing not just the aggregate demand per building but also the ‘ground truth’ demand of individual appliances. In this context, we present UK-DALE: an open-access dataset from the UK recording Domestic Appliance-Level Electricity at a sample rate of 16 kHz for the whole-house and at 1/6 Hz for individual appliances. This is the first open access UK dataset at this temporal resolution. We recorded from five houses, one of which was recorded for 655 days, the longest duration we are aware of for any energy dataset at this sample rate. We also describe the low-cost, open-source, wireless system we built for collecting our dataset.

  11. The UK-DALE dataset, domestic appliance-level electricity demand and whole-house demand from five UK homes.

    Science.gov (United States)

    Kelly, Jack; Knottenbelt, William

    2015-01-01

    Many countries are rolling out smart electricity meters. These measure a home's total power demand. However, research into consumer behaviour suggests that consumers are best able to improve their energy efficiency when provided with itemised, appliance-by-appliance consumption information. Energy disaggregation is a computational technique for estimating appliance-by-appliance energy consumption from a whole-house meter signal. To conduct research on disaggregation algorithms, researchers require data describing not just the aggregate demand per building but also the 'ground truth' demand of individual appliances. In this context, we present UK-DALE: an open-access dataset from the UK recording Domestic Appliance-Level Electricity at a sample rate of 16 kHz for the whole-house and at 1/6 Hz for individual appliances. This is the first open access UK dataset at this temporal resolution. We recorded from five houses, one of which was recorded for 655 days, the longest duration we are aware of for any energy dataset at this sample rate. We also describe the low-cost, open-source, wireless system we built for collecting our dataset.

  12. Investigation of the economic possibilities regarding the reduction of energy intensity for electrical household appliances. Vol. 1

    Energy Technology Data Exchange (ETDEWEB)

    Orth, G

    1980-01-01

    Investigation results concerning the analysis of the energy application for electrical household appliances have not been available up to now. The investigation had the purpose of analysing the energy consumption of energy-intensive household appliances so that energy conservation possibilities with regard to the effectiveness may be developed. The parts of the effective and of the lost energy are being experimentally determined for the following appliances: large-scale hot water tank, washing machine, laundry drier, dish washer, electric hearth, coolers and refrigerators. The influence of the utilization habits on the specific energy consumption and the relationship between the energy application and the application properties are being investigated. On the basis of the investigation results the different possibilities of energy conservation are shown, together with some aspects of economical operation. On the basis of the investigation results also, the potential of the energy conservation, related to practical consumption values, is estimated at about 5-40%, depending on the appliance.

  13. Lifestyle factors in U.S. residential electricity consumption

    International Nuclear Information System (INIS)

    Sanquist, Thomas F.; Orr, Heather; Shui Bin; Bittner, Alvah C.

    2012-01-01

    A multivariate statistical approach to lifestyle analysis of residential electricity consumption is described and illustrated. Factor analysis of selected variables from the 2005 U.S. Residential Energy Consumption Survey (RECS) identified five lifestyle factors reflecting social and behavioral patterns associated with air conditioning, laundry usage, personal computer usage, climate zone of residence, and TV use. These factors were also estimated for 2001 RECS data. Multiple regression analysis using the lifestyle factors yields solutions accounting for approximately 40% of the variance in electricity consumption for both years. By adding the household and market characteristics of income, local electricity price and access to natural gas, variance accounted for is increased to approximately 54%. Income contributed ∼1% unique variance to the models, indicating that lifestyle factors reflecting social and behavioral patterns better account for consumption differences than income. Geographic segmentation of factor scores shows distinct clusters of consumption and lifestyle factors, particularly in suburban locations. The implications for tailored policy and planning interventions are discussed in relation to lifestyle issues. - Highlights: ► Illustrates lifestyle analysis of residential electricity consumption. ► Lifestyle factors based on social and behavioral decisions and equipment use. ► Regression models using lifestyle factors account for 40% of consumption variance. ► Lifestyle factors are stable over time when applied to other data sets. ► Energy reduction opportunities are identified by segmentation analysis.

  14. PAT portable appliance testing : in-service inspection and testing of electrical equipment

    CERN Document Server

    Scaddan, Brian

    2015-01-01

    The Electricity at Work Regulations 1989 requires any electrical system to be constructed, maintained and used in such a manner as to prevent danger. This means that inspection and testing of systems, including portable appliances, is needed in order to determine if maintenance is required. This book explains in clear language what needs to be done and includes expert advice on legislation as well as actual testing. The book contains an appendix providing the electrical fundamentals needed by non-specialists and also has sample questions (with answers) for the C&G 2377 exam. It is also an ideal revision guide for the non-specialist, such as maintenance staff and caretakers who carry out these tasks part-time, alongside their many other duties.

  15. Assessing Residential Customer Satisfaction for Large Electric Utilities

    OpenAIRE

    Lea Kosnik; L. Douglas Smith; Satish Nayak; Maureen Karig; Mark Konya; Kristy Lovett; Zhennan Liu; Harrison Luvai

    2015-01-01

    Electric utilities, like other service organizations, rely on customer surveys to assess the quality of their services and customer relations. With responses to an in-depth survey of 2,216 residential customers, complementary data from geo-coded public sources, aggregate assessments of performance by J.D. Power & Associates from their independent surveys, historical records of individual customer usage and bill payments, streams of published media content and records of actual service deliver...

  16. Electric heat-pumps in residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    1983-03-01

    Since the end of 1979 every other day an electrically operated heat-pump has started operation in Berlin (West). Pros and cons of heat-pumps are a much discussed subject. But what is the opinion of the user. As it is not known the BEWAG carried out a written customer inquiry in the summer 1982. The aim of the inquiry was to improve the advisory service by means of the answers obtained, to obtain information about the reliability or liability to defects of the heat pump, the mechanism they operate on and to know how big the oil substitution potential is. Customer satisfaction with the heat pumps was a further point of interest.

  17. Charging Schedule for Electric Vehicles in Danish Residential Distribution Grids

    DEFF Research Database (Denmark)

    Pillai, Jayakrishnan Radhakrishna; Huang, Shaojun; Bak-Jensen, Birgitte

    2015-01-01

    energy sources like wind in power systems. The EV batteries could be used to charge during periods of excess electricity production from wind power and reduce the charging rate or discharge on deficit of power in the grid, supporting system stability and reliability. By providing such grid services......The prospects of Electric Vehicles (EVs) in providing clean transportation and supporting renewable electricity is widely discussed in sustainable energy forums worldwide. The battery storage of EVs could be used to address the variability and unpredictability of electricity produced from renewable......, the vehicle owner, vehicle fleet operator and other parties involved in the process could economically benefit from the process. This paper investigates an optimal EV charging plan in Danish residential distribution grids in view of supporting high volumes of wind power in electricity grids. The results...

  18. Reforming residential electricity tariff in China: Block tariffs pricing approach

    International Nuclear Information System (INIS)

    Sun, Chuanwang; Lin, Boqiang

    2013-01-01

    The Chinese households that make up approximately a quarter of world households are facing a residential power tariff reform in which a rising block tariff structure will be implemented, and this tariff mechanism is widely used around the world. The basic principle of the structure is to assign a higher price for higher income consumers with low price elasticity of power demand. To capture the non-linear effects of price and income on elasticities, we set up a translog demand model. The empirical findings indicate that the higher income consumers are less sensitive than those with lower income to price changes. We further put forward three proposals of Chinese residential electricity tariffs. Compared to a flat tariff, the reasonable block tariff structure generates more efficient allocation of cross-subsidies, better incentives for raising the efficiency of electricity usage and reducing emissions from power generation, which also supports the living standards of low income households. - Highlights: • We design a rising block tariff structure of residential electricity in China. • We set up a translog demand model to find the non-linear effects on elasticities. • The higher income groups are less sensitive to price changes. • Block tariff structure generates more efficient allocation of cross-subsidies. • Block tariff structure supports the living standards of low income households

  19. An Empirical Study of the Factors Influencing Consumer Behaviour in the Electric Appliances Market

    Directory of Open Access Journals (Sweden)

    Małgorzata Łatuszyńska

    2012-08-01

    Full Text Available This study contributes to a deeper understanding of the impact of different factors on consumer buying behaviour. It analyses the relationship between several independent variables, such as cultural, social, personal, psychological and marketing mix factors, and consumer behaviour (as the dependent variable in the electric appliances market. The purpose of this study is to determine the factors affecting consumer preferences and behaviour in the electric appliances market in Iraq. The data employed to analyse the factors influencing consumers’ purchase decision-making processes were obtained through a questionnaire that was conducted in December 2011 in Basra, a city in southern Iraq. The major findings of the study indicated that, overall, the set of independent variables are weakly associated with the dependent variable. However, the in-depth analysis found that social factors, physical factors, and marketing mix elements are strongly associated with consumer buying behaviour. These analyses make it possible to discover consumer decision-making rules. The results may assist producers and retailers in understanding consumer behaviour and improving consumer satisfaction.

  20. Scenarios for Demand Growth of Metals in Electricity Generation Technologies, Cars, and Electronic Appliances

    Science.gov (United States)

    2018-01-01

    This study provides scenarios toward 2050 for the demand of five metals in electricity production, cars, and electronic appliances. The metals considered are copper, tantalum, neodymium, cobalt, and lithium. The study shows how highly technology-specific data on products and material flows can be used in integrated assessment models to assess global resource and metal demand. We use the Shared Socio-economic Pathways as implemented by the IMAGE integrated assessment model as a starting point. This allows us to translate information on the use of electronic appliances, cars, and renewable energy technologies into quantitative data on metal flows, through application of metal content estimates in combination with a dynamic stock model. Results show that total demand for copper, neodymium, and tantalum might increase by a factor of roughly 2 to 3.2, mostly as a result of population and GDP growth. The demand for lithium and cobalt is expected to increase much more, by a factor 10 to more than 20, as a result of future (hybrid) electric car purchases. This means that not just demographics, but also climate policies can strongly increase metal demand. This shows the importance of studying the issues of climate change and resource depletion together, in one modeling framework. PMID:29533657

  1. Scenarios for Demand Growth of Metals in Electricity Generation Technologies, Cars, and Electronic Appliances.

    Science.gov (United States)

    Deetman, Sebastiaan; Pauliuk, Stefan; van Vuuren, Detlef P; van der Voet, Ester; Tukker, Arnold

    2018-04-17

    This study provides scenarios toward 2050 for the demand of five metals in electricity production, cars, and electronic appliances. The metals considered are copper, tantalum, neodymium, cobalt, and lithium. The study shows how highly technology-specific data on products and material flows can be used in integrated assessment models to assess global resource and metal demand. We use the Shared Socio-economic Pathways as implemented by the IMAGE integrated assessment model as a starting point. This allows us to translate information on the use of electronic appliances, cars, and renewable energy technologies into quantitative data on metal flows, through application of metal content estimates in combination with a dynamic stock model. Results show that total demand for copper, neodymium, and tantalum might increase by a factor of roughly 2 to 3.2, mostly as a result of population and GDP growth. The demand for lithium and cobalt is expected to increase much more, by a factor 10 to more than 20, as a result of future (hybrid) electric car purchases. This means that not just demographics, but also climate policies can strongly increase metal demand. This shows the importance of studying the issues of climate change and resource depletion together, in one modeling framework.

  2. Residential response to voluntary time-of-use electricity rates

    Energy Technology Data Exchange (ETDEWEB)

    Mostafa Baladi, S. [Laurits R. Christensen Associates, Inc. Ames, IA 50011-1070 (United States); Herriges, Joseph A. [Iowa State University, 280D Heady Hall, Department of Economics, Iowa State University, Ames, IA 50011-1070 (United States); Sweeney, Thomas J. [MidAmerican Energy, Des Moines, Iowa (United States)

    1998-09-01

    The response of residential households to voluntary Time-of-Use (TOU) electricity rates is estimated using data from a recent experiment at Midwest Power Systems of Iowa. The study`s design allows us to examine both the participation decision and the customer`s load pattern changes once the TOU rate structure was in effect. Substitution elasticities between on-peak and off-peak electricity usage are estimated and compared to those obtained in earlier mandatory programs, indicating whether program volunteers are more responsive to TOU pricing than the typical household. Attitudinal questionnaires allow us to examine the role of usage perceptions in program participation

  3. Evaluation of methods for the physical characterization of the fine particle emissions from two residential wood combustion appliances

    Science.gov (United States)

    Kinsey, John S.; Kariher, Peter H.; Dong, Yuanji

    The fine particle emissions from a U. S. certified non-catalytic wood stove and a zero-clearance fireplace burning Quercus rubra L. (northern red oak) and Pseudotsuga menziesii (Douglas fir) cordwood each at two different moisture levels were determined. Emission testing was performed using both time-integrated and continuous instrumentation for total particle mass, particle number, particle size distribution, and fixed combustion gases using an atmospheric wind tunnel, full-flow laboratory dilution tunnel, and dilution stack sampler with a comparison made between the three dilution systems and two sampling filter types. The total mass emission factors (EFs) for all dilution systems and filter media are extremely variable ranging from fireplace emissions burning wet oak averaged 11 g kg -1. A substantial number of ultrafine particles in the accumulation size range were also observed during all tests as determined by an Electrical Low Pressure Impactor (ELPI) and Scanning Mobility Particle Sizer. The PM-2.5 (particles ≤2.5 μm in aerodynamic diameter) fractions determined from the ELPI electrometer data ranged from 93 to 98% (mass) depending on appliance type as reported previously by Hays et al. (Aerosol Science, 34, 1061, 2003).

  4. 46 CFR 111.77-3 - Appliances.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Appliances. 111.77-3 Section 111.77-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Appliances and Appliance Circuits § 111.77-3 Appliances. All electrical appliances, including, but...

  5. 78 FR 25728 - Notice of Petition for Waiver of GE Appliances From the Department of Energy Residential...

    Science.gov (United States)

    2013-05-02

    ... refrigerator-freezers that are the focus of this notice.\\1\\ Part B includes definitions, test procedures... a leading manufacturer and marketer of household appliances, including, as relevant to this...

  6. Comparative study of 2 electric and 2 manual toothbrushes in patients with fixed orthodontic appliances.

    Science.gov (United States)

    Thienpont, V; Dermaut, L R; Van Maele, G

    2001-10-01

    The objective of this prospective single-blind crossover clinical trial was to evaluate the efficacy of 4 toothbrushes in 33 children undergoing fixed appliance orthodontic therapy. The toothbrushes included in this study were the Braun Oral-B 3D Plaque Remover (Kronberg, Germany), the Philips-Jordan HP 510 (Philips Domestic Appliances, Groningen, The Netherlands), the Lactona orthodontic toothbrush (Bergen op Zoom, The Netherlands), and the Oral-B Advantage Control Grip (Braun); the first 2 are electric, and the last 2 are manual. Every patient tested each type of toothbrush in a randomly designed sequence. Plaque and gingival scores were recorded at baseline and after every 4-week test period. All patients received professional prophylaxis after each clinical evaluation. The data were analyzed with the Friedman test, which showed no significant differences among the 4 brushes for any of the parameters measured. The Wilcoxon signed rank test, comparing the plaque and the gingival scores between the upper and lower jaw for each brush, indicated that plaque removal was more efficient in the lower jaw than in the upper.

  7. Meeting residential space heating demand with wind-generated electricity

    International Nuclear Information System (INIS)

    Hughes, Larry

    2010-01-01

    Worldwide, many electricity suppliers are faced with the challenge of trying to integrate intermittent renewables, notably wind, into their energy mix to meet the needs of those services that require a continuous supply of electricity. Solutions to intermittency include the use of rapid-response backup generation and chemical or mechanical storage of electricity. Meanwhile, in many jurisdictions with lengthy heating seasons, finding secure and preferably environmentally benign supplies of energy for space heating is also becoming a significant challenge because of volatile energy markets. Most, if not all, electricity suppliers treat these twin challenges as separate issues: supply (integrating intermittent renewables) and demand (electric space heating). However, if space heating demand can be met from an intermittent supply of electricity, then both of these issues can be addressed simultaneously. One such approach is to use off-the-shelf electric thermal storage systems. This paper examines the potential of this approach by applying the output from a 5.15 MW wind farm to the residential heating demands of detached households in the Canadian province of Prince Edward Island. The paper shows that for the heating season considered, up to 500 households could have over 95 percent of their space heating demand met from the wind farm in question. The benefits as well as the limitations of the approach are discussed in detail. (author)

  8. Accelerating residential PV expansion: supply analysis for competitive electricity markets

    International Nuclear Information System (INIS)

    Payne, Adam; Williams, Robert H.; Duke, Richard

    2001-01-01

    Photovoltaic (PV) technology is now sufficiently advanced that market support mechanisms such as net metering plus a renewable portfolio standard (RPS) could induce rapid PV market growth in grid-connected applications. With such support mechanisms, markets would be sufficiently large that manufacturers could profitably build and operate 100 MW p /yr PV module factories, and electricity costs for residential rooftop PV systems would compare favorably with residential electricity prices in certain areas (e.g., California and the greater New York region in the US). This prospect is illustrated by economic and market analyses for one promising technology (amorphous silicon thin-film PV) from the perspectives of both module manufacturers and buyers of new homes with rooftop PV systems. With public policies that reflect the distributed and environmental benefits offered by PV-and that can sustain domestic PV market demand growth at three times the historical growth rate for a period of the order of two decades - PV could provide 3% of total US electricity supply by 2025. (Author)

  9. Residential implementation of critical-peak pricing of electricity

    International Nuclear Information System (INIS)

    Herter, Karen

    2007-01-01

    This paper investigates how critical-peak pricing (CPP) affects households with different usage and income levels, with the goal of informing policy makers who are considering the implementation of CPP tariffs in the residential sector. Using a subset of data from the California Statewide Pricing Pilot of 2003-04, average load change during summer events, annual percent bill change, and post-experiment satisfaction ratings are calculated across six customer segments, categorized by historical usage and income levels. Findings show that high-use customers respond significantly more in kW reduction than do low-use customers, while low-use customers save significantly more in percentage reduction of annual electricity bills than do high-use customers-results that challenge the strategy of targeting only high-use customers for CPP tariffs. Across income levels, average load and bill changes were statistically indistinguishable, as were satisfaction rates-results that are compatible with a strategy of full-scale implementation of CPP rates in the residential sector. Finally, the high-use customers earning less than $50,000 annually were the most likely of the groups to see bill increases-about 5% saw bill increases of 10% or more-suggesting that any residential CPP implementation might consider targeting this customer group for increased energy efficiency efforts

  10. Integration of Solar Photovoltaics and Electric Vehicles in Residential Grids

    DEFF Research Database (Denmark)

    Pillai, Jayakrishnan Radhakrishna; Huang, Shaojun; Bak-Jensen, Birgitte

    2013-01-01

    In the last few years, there is an increased penetration of solar photovoltaic (SPV) units in low voltage (LV) distribution grids. Also electric vehicles (EVs) are introduced to these LV networks. This has caused the distribution networks to be more active and complex as these local generation...... and load units are characterised by unpredictable and diverse operating characteristics. This paper analyses the combined effect of SPVs and EVs in LV Danish residential grids. The EVs charging needs based on typical driving patterns of passenger cars and SPV power profiles during winter/summer days...

  11. A Support System for the Electric Appliance Control Using Pose Recognition

    Science.gov (United States)

    Kawano, Takuya; Yamamoto, Kazuhiko; Kato, Kunihito; Hongo, Hitoshi

    In this paper, we propose an electric appliance control support system for aged and bedridden people using pose recognition. We proposed a pose recognition system that distinguishes between seven poses of the user on the bed. First, the face and arm regions of the user are detected by using the skin color. Our system focuses a recognition region surrounding the face region. Next, the higher order local autocorrelation features within the region are extracted. The linear discriminant analysis creates the coefficient matrix that can optimally distinguish among training data from the seven poses. Our algorithm can recognize the seven poses even if the subject wears different clothes and slightly shifts or slants on the bed. From the experimental results, our system achieved an accuracy rate of over 99 %. Then, we show that it possibles to construct one of a user-friendly system.

  12. Advances in household appliances- A review

    International Nuclear Information System (INIS)

    Bansal, Pradeep; Vineyard, Edward; Abdelaziz, Omar

    2011-01-01

    An overview of options and potential barriers and risks for reducing the energy consumption, peak demand, and emissions for seven key energy consuming residential products (refrigerator-freezers, dishwashers, clothes washers, clothes dryers, electric ovens, gas ovens and microwave ovens) is presented. The paper primarily concentrates on the potential energy savings from the use of advanced technologies in appliances for the U.S. market. The significance and usefulness of each technology was evaluated in order to prioritize the R and D needs to improve energy efficiency of appliances in view of energy savings, cost, and complexity. The paper provides a snapshot of the future R and D needs for each of the technologies along with the associated barriers. Although significant energy savings may be achieved, one of the major barriers in most cases is high first cost. One way of addressing this issue and promoting the introduction of new technologies is to 'level' the playing field for all manufacturers by establishing Minimum Energy Performance Standards (MEPS) which are not cost prohibitive and promoting energy efficient products through incentives to both manufacturers and consumers. - Highlights: → This paper presents latest developments/status of advanced residential appliances. → Stringent minimum energy performance standards can reduce appliance energy use. → There is a potential to reduce energy use in appliances by up to 50%.

  13. Impact of residential PV adoption on Retail Electricity Rates

    International Nuclear Information System (INIS)

    Cai, Desmond W.H.; Adlakha, Sachin; Low, Steven H.; De Martini, Paul; Mani Chandy, K.

    2013-01-01

    The price of electricity supplied from home rooftop photo voltaic (PV) solar cells has fallen below the retail price of grid electricity in some areas. A number of residential households have an economic incentive to install rooftop PV systems and reduce their purchases of electricity from the grid. A significant portion of the costs incurred by utility companies are fixed costs which must be recovered even as consumption falls. Electricity rates must increase in order for utility companies to recover fixed costs from shrinking sales bases. Increasing rates will, in turn, result in even more economic incentives for customers to adopt rooftop PV. In this paper, we model this feedback between PV adoption and electricity rates and study its impact on future PV penetration and net-metering costs. We find that the most important parameter that determines whether this feedback has an effect is the fraction of customers who adopt PV in any year based solely on the money saved by doing so in that year, independent of the uncertainties of future years. These uncertainties include possible changes in rate structures such as the introduction of connection charges, the possibility of PV prices dropping significantly in the future, possible changes in tax incentives, and confidence in the reliability and maintainability of PV. -- Highlights: •Households who install PV reduce their electricity consumption from the grid. •Electricity rates must increase for utility companies to recover its fixed costs. •However, higher electricity rates give households more incentives to adopt PV. •We find that this feedback has significant impact on PV uptake only in later years. •Utility companies could lose a significant fraction of high consumption customers

  14. Agent-based model for electricity consumption and storage to evaluate economic viability of tariff arbitrage for residential sector demand response

    International Nuclear Information System (INIS)

    Zheng, Menglian; Meinrenken, Christoph J.; Lackner, Klaus S.

    2014-01-01

    Highlights: • Storage-based demand response (loadshifting) is underutilized in residential sector. • Economics (arbitrage savings versus equipment cost) are not well understood. • Stochastic demand models and real-life tariffs can illuminate economic viability. • A range of available storage options provide economically viable DR. • Daily/seasonal stochastic demand variations crucial to understanding optimum capacity. - Abstract: Demand response (DR) is one of many approaches to address temporal mismatches in demand and supply of grid electricity. More common in the commercial sector, DR usually refers to reducing consumption at certain hours or seasons, thus reducing peak demand from the grid. In the residential sector, where sophisticated appliance-level controls such as automatic dimming of lights or on-demand lowering of air conditioning are less common, building-based electricity storage to shift grid consumption from peak to off-peak times could provide DR without requiring consumers to operate their appliances on shifted or reduced schedules: Storage would be dispatched to appliances as needed while still shaving peaks on the grid. Technologically, storage and two-way-inverters are readily available to enable such residential DR. Economically, however, the situation is less clear. Specifically, are time-varying electricity tariffs available such that electricity cost reduction via arbitrage could offset manufacturing, financing, and installation costs of the required storage? To address this question we (i) devise an agent-based appliance-level stochastic model to simulate the electricity demand of an average U.S. household; (ii) loadshift the demand via simple dispatch strategies; and (iii) determine potential profits to the building owner, i.e. reduced electricity cost of the modified demand with realistic tariffs (Con Edison, NY) minus storage cost. We determine the economic viability for a range of traditional and advanced storage technologies

  15. The Boom of Electricity Demand in the Residential Sector in the Developing World and the Potential for Energy Efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Letschert, Virginie; McNeil, Michael A.

    2008-05-13

    With the emergence of China as the world's largest energy consumer, the awareness of developing country energy consumption has risen. According to common economic scenarios, the rest of the developing world will probably see an economic expansion as well. With this growth will surely come continued rapid growth in energy demand. This paper explores the dynamics of that demand growth for electricity in the residential sector and the realistic potential for coping with it through efficiency. In 2000, only 66% of developing world households had access to electricity. Appliance ownership rates remain low, but with better access to electricity and a higher income one can expect that households will see their electricity consumption rise significantly. This paper forecasts developing country appliance growth using econometric modeling. Products considered explicitly - refrigerators, air conditioners, lighting, washing machines, fans, televisions, stand-by power, water heating and space heating - represent the bulk of household electricity consumption in developing countries. The resulting diffusion model determines the trend and dynamics of demand growth at a level of detail not accessible by models of a more aggregate nature. In addition, the paper presents scenarios for reducing residential consumption through cost-effective and/or best practice efficiency measures defined at the product level. The research takes advantage of an analytical framework developed by LBNL (BUENAS) which integrates end use technology parameters into demand forecasting and stock accounting to produce detailed efficiency scenarios, which allows for a realistic assessment of efficiency opportunities at the national or regional level. The past decades have seen some of the developing world moving towards a standard of living previously reserved for industrialized countries. Rapid economic development, combined with large populations has led to first China and now India to emerging as &apos

  16. Reduction of electric power consumption in relation to household appliances. Elbesparelser ved husholdningsapparater; Forprojekt

    Energy Technology Data Exchange (ETDEWEB)

    Gydesen, A.

    1989-07-15

    Possibilities were investigated for the reduction of electric power consumption in relation to household appliances, and for cooperation with manufacturers in this respect. It is suggested that in the cases of washing-up machines, and washing and drying machines, hot water from the tap could be utilized. This would mean that the energy consumption would then shift to domestic heating equipment, dual-purpose power plants and district heating plants. Ovens, drying machines, washing machines and washing-up machines could use natural gas, especially in areas where this fuel could be conveyed to each household via pipes. Cooperation with manufacturers seems feasible, especially with regard to electric ovens, saucepans for use in combination with the latter, and water beds. Considering future developments, it is reasonable to expect that ultra sound will be utilized in connection with washing-up and washing machines, moreover it is likely that the use of enzymes in washing powders will mean that washing machines will be able to run on cold water. (AB) 21 refs.

  17. The analysis of Taiwan's residential electricity demand under the electricity tariff policy

    Science.gov (United States)

    Chen, Po-Jui

    In October 2013, the Taiwan Power Company (Taipower), the monopolized state utility service in Taiwan, implemented an electricity tariff adjustment policy to reduce residential electricity demand. Using bi-monthly billing data from 6,932 electricity consumers, this study examine how consumers respond to an increase in electricity prices. This study employs an empirical approach that takes advantage of quasi-random variation over a period of time when household bills were affected by a change in electricity price. The study found that this price increase caused a 1.78% decline in residential electricity consumption, implying a price elasticity of -0.19 for summer-season months and -0.15 for non-summer-season months. The demand for electricity is therefore relatively inelastic, likely because it is hard for people to change their electricity consumption behavior in the short-term. The results of this study highlight that demand-side management cannot be the only lever used to address Taiwan's forecasted decrease in electricity supply.

  18. Photovoltaic electricity generation: Value for residential and commercial sectors

    Science.gov (United States)

    Bhattacharjee, Ujjwal

    The photovoltaic (PV) industry in the US has seen an upsurge in recent years, and PV holds great promise as a renewable technology with no greenhouse gas emissions with its use. We aim to assess the value of PV based electricity for users in the residential and commercial sectors focusing on the financial impacts it has, which may not be greatly recognized. Specifically, we pursue two goals. First, the emerging 'renewable portfolio standard (RPS)' adopted in several states in the country has been a driving force for large scale PV deployment, but financial incentives offered to PV in different RPS states differ considerably. We use life cycle cost model to estimate the cost of PV based electricity for thirty-two RPS states in the country. Results indicate that the levelized cost of PV electricity is high (40 to 60 Cents/kWh). When the contribution of the financial incentives (along with the cost of energy saved) is taken into account, the cost of PV based electricity is negative in some RPS states such as California, New Jersey, New York, while for most of the RPS states the cost of PV electricity continues to remain high. In addition, the states with negative or low cost of PV electricity have been driving the PV diffusion in the residential sector. Therefore, a need to adjust the financial incentive structure in different RPS states is recommended for homogenous development of the residential PV market in the country. Second, we assess the value of the PV in reducing the highest peak load demand in commercial buildings and hence the high value demand charge. The Time-of-Use (TOU) based electricity tariff is widely used by electric utilities in the commercial sector. Energy and peak load are two important facets of the TOU tariff regime. Tools are well established to estimate the energy contribution from a PV system (installed in a commercial building), but not power output on a short time interval. A joint conditional probability model has been developed that

  19. Chemical composition and speciation of particulate organic matter from modern residential small-scale wood combustion appliances.

    Science.gov (United States)

    Czech, Hendryk; Miersch, Toni; Orasche, Jürgen; Abbaszade, Gülcin; Sippula, Olli; Tissari, Jarkko; Michalke, Bernhard; Schnelle-Kreis, Jürgen; Streibel, Thorsten; Jokiniemi, Jorma; Zimmermann, Ralf

    2018-01-15

    Combustion technologies of small-scale wood combustion appliances are continuously developed decrease emissions of various pollutants and increase energy conversion. One strategy to reduce emissions is the implementation of air staging technology in secondary air supply, which became an established technique for modern wood combustion appliances. On that account, emissions from a modern masonry heater fuelled with three types of common logwood (beech, birch and spruce) and a modern pellet boiler fuelled with commercial softwood pellets were investigated, which refer to representative combustion appliances in northern Europe In particular, emphasis was put on the organic constituents of PM2.5, including polycyclic aromatic hydrocarbons (PAHs), oxygenated PAHs (OPAHs) and phenolic species, by targeted and non-targeted mass spectrometric analysis techniques. Compared to conventional wood stoves and pellet boilers, organic emissions from the modern appliances were reduced by at least one order of magnitude, but to a different extent for single species. Hence, characteristic ratios of emission constituents and emission profiles for wood combustion identification and speciation do not hold for this type of advanced combustion technology. Additionally, an overall substantial reduction of typical wood combustion markers, such as phenolic species and anhydrous sugars, were observed. Finally, it was found that slow ignition of log woods changes the distribution of characteristic resin acids and phytosterols as well as their thermal alteration products, which are used as markers for specific wood types. Our results should be considered for wood combustion identification in positive matrix factorisation or chemical mass balance in northern Europe. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Eu-energy label for electric appliances; Das EU-Energielabel fuer Elektrogeraete

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-04-15

    When buying a new appliances to have clear and understandable information on energy consumption to avoid later expensive surprices by to high power cost. But European classifiaction A to G of big household appliances is out of date and must be changed.(orig./GL)

  1. NATURAL GAS VARIABILITY IN CALIFORNIA: ENVIRONMENTAL IMPACTS AND DEVICE PERFORMANCE EXPERIMENTAL EVALUATION OF POLLUTANT EMISSIONS FROM RESIDENTIAL APPLIANCES

    Energy Technology Data Exchange (ETDEWEB)

    Singer, Brett C.; Apte, Michael G.; Black, Douglas R.; Hotchi, Toshifumi; Lucas, Donald; Lunden, Melissa M.; Mirer, Anna G.; Spears, Michael; Sullivan, Douglas P.

    2009-12-01

    The effect of liquefied natural gas on pollutant emissions was evaluated experimentally with used and new appliances in the laboratory and with appliances installed in residences, targeting information gaps from previous studies. Burner selection targeted available technologies that are projected to comprise the majority of installed appliances over the next decade. Experiments were conducted on 13 cooktop sets, 12 ovens, 5 broiler burners, 5 storage water heaters, 4 forced air furnaces, 1 wall furnace, and 6 tankless water heaters. Air-free concentrations and fuel-based emission factors were determined for carbon monoxide, nitrogen oxides, nitrogen dioxide, and the number of (predominantly ultrafine) particles over complete burns?including transient effects (device warm-up and intermittent firing of burners) following ignition--and during more stable end-of-burn conditions. Formaldehyde was measured over multi-burn cycles. The baseline fuel was Northern California line gas with Wobbe number (a measure of fuel energy delivery rate) of 1320-1340; test fuels had Wobbe numbers of roughly 1390 and 1420, and in some cases 1360. No ignition or operational problems were observed during test fuel use. Baseline emissions varied widely across and within burner groups and with burner operational mode. Statistically significant emissions changes were observed for some pollutants on some burners.

  2. Accelerating residential PV expansion: demand analysis for competitive electricity markets

    International Nuclear Information System (INIS)

    Duke, Richard; Williams, Robert; Payne, Adam

    2005-01-01

    This article quantifies the potential market for grid-connected, residential photovoltaic (PV) electricity integrated into new homes built in the US. It complements an earlier supply-side analysis by the authors that demonstrates the potential to reduce PV module prices below $1.5/W p by scaling up existing thin-film technology in 100 MW p /yr manufacturing facilities. The present article demonstrates that, at that price, PV modules may be cost effective in 125,000 new home installations per year (0.5 GW p /yr). While this market is large enough to support multiple scaled up thin-film PV factories, inefficient energy pricing and demand-side market failures will inhibit prospective PV consumers without strong public policy support. Net metering rules, already implemented in many states to encourage PV market launch, represent a crude but reasonable surrogate for efficient electricity pricing mechanisms that may ultimately emerge to internalize the externality benefits of PV. These public benefits include reduced air pollution damages (estimated costs of damage to human health from fossil fuel power plants are presented in Appendix A), deferral of transmission and distribution capital expenditures, reduced exposure to fossil fuel price risks, and increased electricity system reliability for end users. Thus, net metering for PV ought to be implemented as broadly as possible and sustained until efficient pricing is in place. Complementary PV 'buydowns' (e.g., a renewable portfolio standard with a specific PV requirement) are needed to jumpstart regional PV markets

  3. How do household characteristics affect appliance usage? Application of conditional demand analysis to Japanese household data

    International Nuclear Information System (INIS)

    Matsumoto, Shigeru

    2016-01-01

    Although both appliance ownership and usage patterns determine residential electricity consumption, it is less known how households actually use their appliances. In this study, we conduct conditional demand analyses to break down total household electricity consumption into a set of demand functions for electricity usage, across 12 appliance categories. We then examine how the socioeconomic characteristics of the households explain their appliance usage. Analysis of micro-level data from the Nation Survey of Family and Expenditure in Japan reveals that the family and income structure of households affect appliance usage. Specifically, we find that the presence of teenagers increases both air conditioner and dishwasher use, labor income and nonlabor income affect microwave usage in different ways, air conditioner usage decreases as the wife's income increases, and microwave usage decreases as the husband's income increases. Furthermore, we find that households use more electricity with new personal computers than old ones; this implies that the replacement of old personal computers increases electricity consumption. - Highlights: •We conduct conditional demand analyses to study household appliance usage. •Micro-level data from the National Survey of Family and Expenditure in Japan are analyzed. •We show how household characteristics determine appliance usage. •High-income households use specific appliances less intensively than low-income households. •The replacement of old TVs and PCs lead to greater electricity consumption.

  4. 77 FR 2743 - Recovery Directorate Fact Sheet 9580.213, Residential Electrical Meter Repair-“Power Up”

    Science.gov (United States)

    2012-01-19

    ...] Recovery Directorate Fact Sheet 9580.213, Residential Electrical Meter Repair--``Power Up'' AGENCY: Federal..., Residential Electrical Meter Repair--``Power Up.'' DATES: Comments must be received by February 21, 2012... authority, FEMA may fund the repair of residential electrical meters damaged in a major disaster or...

  5. Market-based Demand Response via Residential Plug-in Electric Vehicles in Smart Grids

    OpenAIRE

    Rassaei, Farshad; Soh, Wee-Seng; Chua, Kee-Chaing

    2015-01-01

    Flexibility in power demand, diverse usage patterns and storage capability of plug-in electric vehicles (PEVs) grow the elasticity of residential electricity demand remarkably. This elasticity can be utilized to form the daily aggregated demand profile and/or alter instantaneous demand of a system wherein a large number of residential PEVs share one electricity retailer or an aggregator. In this paper, we propose a demand response (DR) technique to manage vehicle-to-grid (V2G) enabled PEVs' e...

  6. BLOND, a building-level office environment dataset of typical electrical appliances.

    Science.gov (United States)

    Kriechbaumer, Thomas; Jacobsen, Hans-Arno

    2018-03-27

    Energy metering has gained popularity as conventional meters are replaced by electronic smart meters that promise energy savings and higher comfort levels for occupants. Achieving these goals requires a deeper understanding of consumption patterns to reduce the energy footprint: load profile forecasting, power disaggregation, appliance identification, startup event detection, etc. Publicly available datasets are used to test, verify, and benchmark possible solutions to these problems. For this purpose, we present the BLOND dataset: continuous energy measurements of a typical office environment at high sampling rates with common appliances and load profiles. We provide voltage and current readings for aggregated circuits and matching fully-labeled ground truth data (individual appliance measurements). The dataset contains 53 appliances (16 classes) in a 3-phase power grid. BLOND-50 contains 213 days of measurements sampled at 50kSps (aggregate) and 6.4kSps (individual appliances). BLOND-250 consists of the same setup: 50 days, 250kSps (aggregate), 50kSps (individual appliances). These are the longest continuous measurements at such high sampling rates and fully-labeled ground truth we are aware of.

  7. BLOND, a building-level office environment dataset of typical electrical appliances

    Science.gov (United States)

    Kriechbaumer, Thomas; Jacobsen, Hans-Arno

    2018-03-01

    Energy metering has gained popularity as conventional meters are replaced by electronic smart meters that promise energy savings and higher comfort levels for occupants. Achieving these goals requires a deeper understanding of consumption patterns to reduce the energy footprint: load profile forecasting, power disaggregation, appliance identification, startup event detection, etc. Publicly available datasets are used to test, verify, and benchmark possible solutions to these problems. For this purpose, we present the BLOND dataset: continuous energy measurements of a typical office environment at high sampling rates with common appliances and load profiles. We provide voltage and current readings for aggregated circuits and matching fully-labeled ground truth data (individual appliance measurements). The dataset contains 53 appliances (16 classes) in a 3-phase power grid. BLOND-50 contains 213 days of measurements sampled at 50kSps (aggregate) and 6.4kSps (individual appliances). BLOND-250 consists of the same setup: 50 days, 250kSps (aggregate), 50kSps (individual appliances). These are the longest continuous measurements at such high sampling rates and fully-labeled ground truth we are aware of.

  8. Electricity consumption in G7 countries: A panel cointegration analysis of residential demand elasticities

    International Nuclear Information System (INIS)

    Narayan, Paresh Kumar; Smyth, Russell; Prasad, Arti

    2007-01-01

    This article applies recently developed panel unit root and panel cointegration techniques to estimate the long-run and short-run income and price elasticities for residential demand for electricity in G7 countries. The panel results indicate that in the long-run residential demand for electricity is price elastic and income inelastic. The study concludes that from an environmental perspective there is potential to use pricing policies in the G7 countries to curtail residential electricity demand, and thus curb carbon emissions, in the long run. (author)

  9. Residential applliance data, assumptions and methodology for end-use forecasting with EPRI-REEPS 2.1

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, R.J,; Johnson, F.X.; Brown, R.E.; Hanford, J.W.; Kommey, J.G.

    1994-05-01

    This report details the data, assumptions and methodology for end-use forecasting of appliance energy use in the US residential sector. Our analysis uses the modeling framework provided by the Appliance Model in the Residential End-Use Energy Planning System (REEPS), which was developed by the Electric Power Research Institute. In this modeling framework, appliances include essentially all residential end-uses other than space conditioning end-uses. We have defined a distinct appliance model for each end-use based on a common modeling framework provided in the REEPS software. This report details our development of the following appliance models: refrigerator, freezer, dryer, water heater, clothes washer, dishwasher, lighting, cooking and miscellaneous. Taken together, appliances account for approximately 70% of electricity consumption and 30% of natural gas consumption in the US residential sector. Appliances are thus important to those residential sector policies or programs aimed at improving the efficiency of electricity and natural gas consumption. This report is primarily methodological in nature, taking the reader through the entire process of developing the baseline for residential appliance end-uses. Analysis steps documented in this report include: gathering technology and market data for each appliance end-use and specific technologies within those end-uses, developing cost data for the various technologies, and specifying decision models to forecast future purchase decisions by households. Our implementation of the REEPS 2.1 modeling framework draws on the extensive technology, cost and market data assembled by LBL for the purpose of analyzing federal energy conservation standards. The resulting residential appliance forecasting model offers a flexible and accurate tool for analyzing the effect of policies at the national level.

  10. Study of rational energy consumption in electric appliances. An integrated approach; Estudio de racionalizacion del consumo energetico en electrodomesticos. Un enfoque integrador

    Energy Technology Data Exchange (ETDEWEB)

    Massa, Pablo A.; Romero Tirado, Rene R. [La Plata Univ. Nacional (Argentina). Facultad de Ingenieria. Dept. de Electrotecnia

    1997-12-31

    This work presents a global and integrated approach about rational energy consumption concerning the use of electric appliances based on studies carried out in this investigation and information obtained through a joint action of government agents and electric power manufacturers, producers and distributors. It also presents a program named `procaeh`(home electric appliances quality program) in the scope of the communications and energy bureau and energy rational use (URE) management 8 refs., 2 figs., 7 tabs.; e-mail: massa at isis.unlp.edu.ar

  11. Exploring variance in residential electricity consumption: Household features and building properties

    International Nuclear Information System (INIS)

    Bartusch, Cajsa; Odlare, Monica; Wallin, Fredrik; Wester, Lars

    2012-01-01

    Highlights: ► Statistical analysis of variance are of considerable value in identifying key indicators for policy update. ► Variance in residential electricity use is partly explained by household features. ► Variance in residential electricity use is partly explained by building properties. ► Household behavior has a profound impact on individual electricity use. -- Abstract: Improved means of controlling electricity consumption plays an important part in boosting energy efficiency in the Swedish power market. Developing policy instruments to that end requires more in-depth statistics on electricity use in the residential sector, among other things. The aim of the study has accordingly been to assess the extent of variance in annual electricity consumption in single-family homes as well as to estimate the impact of household features and building properties in this respect using independent samples t-tests and one-way as well as univariate independent samples analyses of variance. Statistically significant variances associated with geographic area, heating system, number of family members, family composition, year of construction, electric water heater and electric underfloor heating have been established. The overall result of the analyses is nevertheless that variance in residential electricity consumption cannot be fully explained by independent variables related to household and building characteristics alone. As for the methodological approach, the results further suggest that methods for statistical analysis of variance are of considerable value in indentifying key indicators for policy update and development.

  12. Impact of Uncoordinated Plug-in Electric Vehicle Charging on Residential Power Demand

    Energy Technology Data Exchange (ETDEWEB)

    Muratori, Matteo [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2018-01-22

    Electrification of transport offers opportunities to increase energy security, reduce carbon emissions, and improve local air quality. Plug-in electric vehicles (PEVs) are creating new connections between the transportation and electric sectors, and PEV charging will create opportunities and challenges in a system of growing complexity. Here, I use highly resolved models of residential power demand and PEV use to assess the impact of uncoordinated in-home PEV charging on residential power demand. While the increase in aggregate demand might be minimal even for high levels of PEV adoption, uncoordinated PEV charging could significantly change the shape of the aggregate residential demand, with impacts for electricity infrastructure, even at low adoption levels. Clustering effects in vehicle adoption at the local level might lead to high PEV concentrations even if overall adoption remains low, significantly increasing peak demand and requiring upgrades to the electricity distribution infrastructure. This effect is exacerbated when adopting higher in-home power charging.

  13. Impact of uncoordinated plug-in electric vehicle charging on residential power demand

    Science.gov (United States)

    Muratori, Matteo

    2018-03-01

    Electrification of transport offers opportunities to increase energy security, reduce carbon emissions, and improve local air quality. Plug-in electric vehicles (PEVs) are creating new connections between the transportation and electric sectors, and PEV charging will create opportunities and challenges in a system of growing complexity. Here, I use highly resolved models of residential power demand and PEV use to assess the impact of uncoordinated in-home PEV charging on residential power demand. While the increase in aggregate demand might be minimal even for high levels of PEV adoption, uncoordinated PEV charging could significantly change the shape of the aggregate residential demand, with impacts for electricity infrastructure, even at low adoption levels. Clustering effects in vehicle adoption at the local level might lead to high PEV concentrations even if overall adoption remains low, significantly increasing peak demand and requiring upgrades to the electricity distribution infrastructure. This effect is exacerbated when adopting higher in-home power charging.

  14. Moving from Outsider to Insider: Peer Status and Partnerships between Electricity Utilities and Residential Consumers

    Science.gov (United States)

    Morris, Peter; Buys, Laurie; Vine, Desley

    2014-01-01

    An electricity demand reduction project based on comprehensive residential consumer engagement was established within an Australian community in 2008. By 2011, both the peak demand and grid supplied electricity consumption had decreased to below pre-intervention levels. This case study research explored the relationship developed between the utility, community and individual consumer from the residential customer perspective through qualitative research of 22 residential households. It is proposed that an energy utility can be highly successful at peak demand reduction by becoming a community member and a peer to residential consumers and developing the necessary trust, access, influence and partnership required to create the responsive environment to change. A peer-community approach could provide policymakers with a pathway for implementing pro-environmental behaviour for low carbon communities, as well as peak demand reduction, thereby addressing government emission targets while limiting the cost of living increases from infrastructure expenditure. PMID:24979234

  15. Price freezes, durables and residential electricity demand - Evidence from the Greater Buenos Aires

    Energy Technology Data Exchange (ETDEWEB)

    Casarin, Ariel; Delfino, Maria Eugenia

    2010-09-15

    This paper examines the determinants of residential electricity demand in the Greater Buenos Aires between 1997 and 2006. During the second half of this period, residential tariffs remained nominally fixed, while an income boom boosted up the sales of durables. This study differs from previous works in that it explicitly considers the impact of the stock of air-conditioners on residential demand. The paper reports short- and long-run elasticities and examines the contribution of prices and durables to recent demand growth. Simulations illustrate the impact of prices and durables on future demand.

  16. The performance of residential micro-cogeneration coupled with thermal and electrical storage

    Science.gov (United States)

    Kopf, John

    Over 80% of residential secondary energy consumption in Canada and Ontario is used for space and water heating. The peak electricity demands resulting from residential energy consumption increase the reliance on fossil-fuel generation stations. Distributed energy resources can help to decrease the reliance on central generation stations. Presently, distributed energy resources such as solar photovoltaic, wind and bio-mass generation are subsidized in Ontario. Micro-cogeneration is an emerging technology that can be implemented as a distributed energy resource within residential or commercial buildings. Micro-cogeneration has the potential to reduce a building's energy consumption by simultaneously generating thermal and electrical power on-site. The coupling of a micro-cogeneration device with electrical storage can improve the system's ability to reduce peak electricity demands. The performance potential of micro-cogeneration devices has yet to be fully realized. This research addresses the performance of a residential micro-cogeneration device and it's ability to meet peak occupant electrical loads when coupled with electrical storage. An integrated building energy model was developed of a residential micro-cogeneration system: the house, the micro-cogeneration device, all balance of plant and space heating components, a thermal storage device, an electrical storage device, as well as the occupant electrical and hot water demands. This model simulated the performance of a micro-cogeneration device coupled to an electrical storage system within a Canadian household. A customized controller was created in ESP-r to examine the impact of various system control strategies. The economic performance of the system was assessed from the perspective of a local energy distribution company and an end-user under hypothetical electricity export purchase price scenarios. It was found that with certain control strategies the micro-cogeneration system was able to improve the

  17. Residential electricity consumption in Portugal: Findings from top-down and bottom-up models

    International Nuclear Information System (INIS)

    Wiesmann, Daniel; Lima Azevedo, Ines; Ferrao, Paulo; Fernandez, John E.

    2011-01-01

    An econometric study of the Portuguese residential electricity consumption is presented, with a focus on the influence of dwelling characteristics on consumption. The relationship between the dwelling and household characteristics on per capita residential electricity consumption is estimated at two different scales, involving two distinct databases: the first includes data at the municipality level for 2001, the second is the most recent Portuguese consumer expenditure survey that was collected in 2005 and 2006. The results of the analysis at both scales are consistent and indicate that household and dwelling characteristics have a significant influence on residential electricity consumption. Our results show that in Portugal the direct effect of income on electricity consumption is low and becomes smaller when more relevant control variables are included in the analysis. Future demand of electricity in Portugal will be significantly influenced by trends in socioeconomic factors as well as changes in the building stock. These trends should be taken in consideration in the formulation of policy measures to reduce electricity consumption. - Research highlights: → Econometric study of per capita residential electricity consumption in Portugal. → Comparing models at two levels of aggregation: by municipality and by household. → Using proxies for the dwelling characteristics on the municipality level. → Results from both scales are consistent. → Income elasticity is low and the influence of dwelling characteristics is significant.

  18. Predicting summer residential electricity demand across the U.S.A using climate information

    Science.gov (United States)

    Sun, X.; Wang, S.; Lall, U.

    2017-12-01

    We developed a Bayesian Hierarchical model to predict monthly residential per capita electricity consumption at the state level across the USA using climate information. The summer period was selected since cooling requirements may be directly associated with electricity use, while for winter a mix of energy sources may be used to meet heating needs. Historical monthly electricity consumption data from 1990 to 2013 were used to build a predictive model with a set of corresponding climate and non-climate covariates. A clustering analysis was performed first to identify groups of states that had similar temporal patterns for the cooling degree days of each state. Then, a partial pooling model was applied to each cluster to assess the sensitivity of monthly per capita residential electricity demand to each predictor (including cooling-degree-days, gross domestic product (GDP) per capita, per capita electricity demand of previous month and previous year, and the residential electricity price). The sensitivity of residential electricity to cooling-degree-days has an identifiable geographic distribution with higher values in northeastern United States.

  19. Short- and long-run time-of-use price elasticities in Swiss residential electricity demand

    International Nuclear Information System (INIS)

    Filippini, Massimo

    2011-01-01

    This paper presents an empirical analysis on the residential demand for electricity by time-of-day. This analysis has been performed using aggregate data at the city level for 22 Swiss cities for the period 2000-2006. For this purpose, we estimated two log-log demand equations for peak and off-peak electricity consumption using static and dynamic partial adjustment approaches. These demand functions were estimated using several econometric approaches for panel data, for example LSDV and RE for static models, and LSDV and corrected LSDV estimators for dynamic models. The attempt of this empirical analysis has been to highlight some of the characteristics of the Swiss residential electricity demand. The estimated short-run own price elasticities are lower than 1, whereas in the long-run these values are higher than 1. The estimated short-run and long-run cross-price elasticities are positive. This result shows that peak and off-peak electricity are substitutes. In this context, time differentiated prices should provide an economic incentive to customers so that they can modify consumption patterns by reducing peak demand and shifting electricity consumption from peak to off-peak periods. - Highlights: → Empirical analysis on the residential demand for electricity by time-of-day. → Estimators for dynamic panel data. → Peak and off-peak residential electricity are substitutes.

  20. Residential electricity consumption in Portugal: Findings from top-down and bottom-up models

    Energy Technology Data Exchange (ETDEWEB)

    Wiesmann, Daniel, E-mail: daniel.wiesmann@ist.utl.p [Instituto Superior Tecnico, Technical University of Lisbon, Avenida Rovisco Pais 1, 1049-001 Lisbon (Portugal); Lima Azevedo, Ines [Department of Engineering and Public Policy, Carnegie Mellon University, 5000 Forbes Avenue, Pittsburgh, PA 15213 (United States); Ferrao, Paulo [Instituto Superior Tecnico, Technical University of Lisbon, Avenida Rovisco Pais 1, 1049-001 Lisbon (Portugal); Fernandez, John E. [Department of Architecture, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139 (United States)

    2011-05-15

    An econometric study of the Portuguese residential electricity consumption is presented, with a focus on the influence of dwelling characteristics on consumption. The relationship between the dwelling and household characteristics on per capita residential electricity consumption is estimated at two different scales, involving two distinct databases: the first includes data at the municipality level for 2001, the second is the most recent Portuguese consumer expenditure survey that was collected in 2005 and 2006. The results of the analysis at both scales are consistent and indicate that household and dwelling characteristics have a significant influence on residential electricity consumption. Our results show that in Portugal the direct effect of income on electricity consumption is low and becomes smaller when more relevant control variables are included in the analysis. Future demand of electricity in Portugal will be significantly influenced by trends in socioeconomic factors as well as changes in the building stock. These trends should be taken in consideration in the formulation of policy measures to reduce electricity consumption. - Research highlights: {yields} Econometric study of per capita residential electricity consumption in Portugal. {yields} Comparing models at two levels of aggregation: by municipality and by household. {yields} Using proxies for the dwelling characteristics on the municipality level. {yields} Results from both scales are consistent. {yields} Income elasticity is low and the influence of dwelling characteristics is significant.

  1. The effectiveness of energy efficiency improvement in a developing country: Rebound effect of residential electricity use in South Korea

    International Nuclear Information System (INIS)

    Jin, Sang-Hyeon

    2007-01-01

    The government of South Korea considers an energy efficiency improvement policy an effective economic measure for climate change like many other governments. But it is unaware of any 'rebound effect', the unexpected result of energy efficiency improvement. So the rebound effect of residential electricity use in South Korea was estimated using two different scales in this paper. At the macro level, the rebound effect was estimated indirectly by using price elasticity, and at the micro level, the rebound effect of individual home appliances was estimated directly by using a non-linear relationship between energy efficiency and energy use. At the macro level, the long- and short-term results of rebound effect were estimated at 30% and 38%, respectively. Also at the micro level, the rebound effect of air conditioners was 57-70%; while refrigerators showed only a composite of rebound and income effects. Finally, there was no backfire effect, and efficiency improvement brought energy reduction. In conclusion, these suggest that rebound effect is an important factor that the government of South Korea must consider when planning its energy efficiency improvement policy. (author)

  2. The residential electricity sector in Denmark: A description of current conditions

    DEFF Research Database (Denmark)

    Kitzing, Lena; Katz, Jonas; Schröder, Sascha Thorsten

    We provide an overview of the current conditions and framework for residential electricity consumption in Denmark. This includes a general overview of the sector, the retail market and the regulatory framework. We describe the regulations currently in place and changes which have been decided...... in the area, which are listed in the Glossary towards the end of the report. We also attach a list and description of the major sources of information and data that can be obtained and downloaded for analysis of the Danish residential electricity sector....

  3. 78 FR 7394 - Notification of Proposed Production Activity; GE Appliances; Subzone 29C (Electric Water Heaters...

    Science.gov (United States)

    2013-02-01

    ..., freezers, apparel washing machines and dryers, electric ranges, and air-conditioners, under FTZ procedures...), fan motors, fans, filter/ dryers, expansion valves, accumulators, parts of electric water heaters...

  4. Integration of plug-in hybrid electric vehicles (PHEV) with grid connected residential photovoltaic energy systems

    Science.gov (United States)

    Nagarajan, Adarsh; Shireen, Wajiha

    2013-06-01

    This paper proposes an approach for integrating Plug-In Hybrid Electric Vehicles (PHEV) to an existing residential photovoltaic system, to control and optimize the power consumption of residential load. Control involves determining the source from which residential load will be catered, where as optimization of power flow reduces the stress on the grid. The system built to achieve the goal is a combination of the existing residential photovoltaic system, PHEV, Power Conditioning Unit (PCU), and a controller. The PCU involves two DC-DC Boost Converters and an inverter. This paper emphasizes on developing the controller logic and its implementation in order to accommodate the flexibility and benefits of the proposed integrated system. The proposed controller logic has been simulated using MATLAB SIMULINK and further implemented using Digital Signal Processor (DSP) microcontroller, TMS320F28035, from Texas Instruments

  5. Responsiveness of residential electricity demand to dynamic tariffs: Experiences from a large field test in the Netherlands

    OpenAIRE

    Klaassen, EAM; Kobus, C.B.A.; Frunt, J; Slootweg, JG

    2016-01-01

    To efficiently facilitate the energy transition it is essential to evaluate the potential of demand response in practice. Based on the results of a Dutch smart grid pilot, this paper assesses the potential of both manual and semi-automated demand response in residential areas. To stimulate demand response, a dynamic tariff and smart appliances were used. The participating households were informed about the tariff day-ahead through a home energy management system, connected to a display instal...

  6. RESIDENTIAL EXPOSURE TO EXTREMELY LOW FREQUENCY ELECTRIC AND MAGNETIC FIELDS IN THE CITY OF RAMALLAH-PALESTINE.

    Science.gov (United States)

    Abuasbi, Falastine; Lahham, Adnan; Abdel-Raziq, Issam Rashid

    2018-04-01

    This study was focused on the measurement of residential exposure to power frequency (50-Hz) electric and magnetic fields in the city of Ramallah-Palestine. A group of 32 semi-randomly selected residences distributed amongst the city were under investigations of fields variations. Measurements were performed with the Spectrum Analyzer NF-5035 and were carried out at one meter above ground level in the residence's bedroom or living room under both zero and normal-power conditions. Fields' variations were recorded over 6-min and some times over few hours. Electric fields under normal-power use were relatively low; ~59% of residences experienced mean electric fields V/m. The highest mean electric field of 66.9 V/m was found at residence R27. However, electric field values were log-normally distributed with geometric mean and geometric standard deviation of 9.6 and 3.5 V/m, respectively. Background electric fields measured under zero-power use, were very low; ~80% of residences experienced background electric fields V/m. Under normal-power use, the highest mean magnetic field (0.45 μT) was found at residence R26 where an indoor power substation exists. However, ~81% of residences experienced mean magnetic fields residences showed also a log-normal distribution with geometric mean and geometric standard deviation of 0.04 and 3.14 μT, respectively. Under zero-power conditions, ~7% of residences experienced average background magnetic field >0.1 μT. Fields from appliances showed a maximum mean electric field of 67.4 V/m from hair dryer, and maximum mean magnetic field of 13.7 μT from microwave oven. However, no single result surpassed the ICNIRP limits for general public exposures to ELF fields, but still, the interval 0.3-0.4 μT for possible non-thermal health impacts of exposure to ELF magnetic fields, was experienced in 13% of the residences.

  7. Index decomposition analysis of residential energy consumption in China: 2002–2010

    International Nuclear Information System (INIS)

    Nie, Hongguang; Kemp, René

    2014-01-01

    Highlights: • We examine residential energy use in China and predict household electricity use. • We decompose the dramatic increase of residential energy use in China. • Driving factors consist of population, floor space, energy mix and appliances. • Floor space per capita effect becomes increasingly important over time. • Electricity use from appliances will continue to rise despite a saturation. - Abstract: Residential energy consumption in China increased dramatically over the period of 2002–2010. In this paper, we undertake a decomposition analysis of changes in energy use by Chinese households for five energy-using activities: space heating/cooling, cooking, lighting and electric appliances. We investigate to what extent changes in energy use are due to changes from appliances and to change in floor space, population and energy mix. Our decomposition analysis is based on the logarithmic mean Divisia index technique using data from the China statistical yearbook and China energy statistical yearbook in the period of 2002–2010. According to our results, the increase in energy-using appliances is the biggest contributor to the increase of residential energy consumption during 2002–2010 but the effect declines over time, due to energy efficiency improvements in those appliances. The second most important contributor is floor space per capita, which increased with 28%. Of the four factors, population is the most stable factor and energy mix is the least important factor. We predicted electricity use, with the help of regression-based predictions for ownership of appliances and the energy efficiency of appliances. We found that electricity use will continue to rise despite a gradual saturation of demand

  8. Electrical Grid Stability Enhancement using Smart Home Frequency-response Grid -Friendly Appliance System

    Directory of Open Access Journals (Sweden)

    Muawiya A. Kaigama

    2016-03-01

    Full Text Available Load shedding is a powerful scheme used for corrective and preventive measures; corrective to restore system’s stability and preventive to avoid catastrophic failure. However, the affected end users are deprived of power supply absolutely with no choice. This paper presents the design, development, feasibility and merits of Frequency-response Grid -Friendly Appliance System (FRGFAS in a smart home. FRGFAS is a decentralized Adaptive Load Shaving(ALS device that supports grid’s system stability by sensing grid’s frequency deterioration level and turns ON/OFF loads accordingly. The FRGFAS permits end users to carry out load shaving at their scale of preference in smart homes via flexible demand responses and automates outdoor lighting to optimum operational hours. FRGFAS obviate load shedding by shaving loads whenever the system is in distress and reset loads supply to the normal state when it stabilizes, this Consequently increases the end user comfort zone and averts a blackout.

  9. The effect of economic factors and energy efficiency programs on residential electricity consumption

    Science.gov (United States)

    Sakai, Mihoko

    Many countries have implemented policies to correct market and behavioral failures that lead to inefficient energy use. It is important to know what factors and policies can effectively overcome such failures and improve energy efficiency; however, a comprehensive analysis has been difficult because of data limitations. Using state scores compiled by American organizations recently, and adopting fixed-effects regression models, I analyze the joint impacts of relevant factors and policy programs on residential electricity consumption in each U.S. state. The empirical results reveal that increases in electricity price have small and negative effects, and increases in personal income have positive effects on residential electricity sales per capita (a measure of energy efficiency). The results suggest that it may take time for economic factors to affect electricity sales. The effects of personal income suggest the difficulty of controlling residential electricity consumption; however, they also imply that there is some room in households to reduce electricity use. The study also finds that programs and budgets of several policies seem to be associated with electricity sales. The estimates from a model including interaction terms suggest the importance of including multiple policies when analyzing and designing policies to address electricity efficiency. The results also imply the possibility of rebound effects of some policies, whereby improvements in energy efficiency lead to increases in energy consumption due to the associated lower per unit cost. Future studies should analyze both short-term and long-term effects of economic factors and policies, based on improved and accumulated time series and panel data, in order to design more effective policies for improving residential electricity efficiency.

  10. Estimation of Iranian price elasticities of residential electricity demand

    Directory of Open Access Journals (Sweden)

    Yeganeh Mousavi Jahromi

    2014-06-01

    Full Text Available This paper presents a study to determine demand for electricity in city of Yazd, Iran over the period of 1998-2008. Using vector error correction model (VECM based on seasonal information, the study determines that electricity has no elasticity in short term in household expenditure. Therefore, government policy on increasing price of electricity will not influence demand. However, electricity maintains elasticity over the long-term period and an increase on price of electricity could motivate consumers to reduce their consumption by purchasing energy efficient facilities. Therefore, any governmental strategy to increase price may have positive impact on economy. The study also detects a positive and meaningful relationship between temperature and electricity consumption.

  11. A critical look at residential electricity conservation campaigns in a developing country environment

    International Nuclear Information System (INIS)

    Martino Jannuzzi, G. de; Ferreira Santos, V. dos

    1993-01-01

    This paper analyse survey results of the effectiveness of information campaigns to promote energy efficiency among residential consumers in Brazil. The survey found that consumers have a relatively good knowledge of conservation measures to improve electricity usage. Nevertheless, other approaches are needed to promote energy conservation in the household sector. (author). 3 refs, 4 figs, 2 tabs

  12. Experimental device for the residential heating with heat pipe and electric heat storage blocks

    Energy Technology Data Exchange (ETDEWEB)

    Vasiliev, L L; Boldak, I M; Domorod, L S; Rabetsky, M I; Schirokov, E I [AN Belorusskoj SSR, Minsk (Belarus). Inst. Teplo- i Massoobmena

    1992-01-01

    Residential heating using electric heat storage blocks nowadays is an actual problem from the point of view of heat recovery and nature protection. In the Luikov Heat and Mass Transfer Institute a new residential electrical heater capable of heating chambers by controlling air temperature and heat output using heat pipes and an electric heat storage block was developed. This heater (BETA) is fed from the source of energy and during 7 h of night time accumulates energy sufficiently to heat 10 m{sup 3} during 24 h. Heating device BETA has a ceramic thermal storage block, electric heaters and a heat pipe with evaporator inside the ceramic block and constant temperature (65{sup o}C) finned condenser outside it. The condenser temperature could be controlled easily. BETA is compact, has high thermal response, accurate air temperature control and safe operation. Such types of residential heaters are necessary for heating residential and office building in the Mogilev and Gomel regions in Byelorussia which suffered after the Chernobyl catastrophe. (Author).

  13. Home Appliance Load Scheduling with SEMIAH

    DEFF Research Database (Denmark)

    Jacobsen, Rune Hylsberg; Ghasem Azar, Armin; Zhang, Qi

    2015-01-01

    The European research project SEMIAH aims at designing a scalable infrastructure for residential demand response. This paper presents the progress towards a centralized load scheduling algorithm for controlling home appliances taking power grid constraints and satisfaction of consumers into account....

  14. Smart electric storage heating and potential for residential demand response

    OpenAIRE

    Darby, S

    2017-01-01

    Low-carbon transition plans for temperate and sub-polar regions typically involve some electrification of space heating. This poses challenges to electricity system operation and market design, as it increases overall demand and alters the temporal patterns of that demand. One response to the challenge is to ‘smarten’ electrical heating, enabling it to respond to network conditions by storing energy at times of plentiful supply, releasing it in response to customer demands and offering rapid-...

  15. What do customers want from improved residential electricity services? Evidence from a choice experiment

    International Nuclear Information System (INIS)

    Huh, Sung-Yoon; Woo, JongRoul; Lim, Sesil; Lee, Yong-Gil; Kim, Chang Seob

    2015-01-01

    Improvements in customer satisfaction as well as product/service quality represent a common objective of all businesses, and electricity services are no exception. Using choice experiments and a mixed logit model, this study quantitatively analyzes customers' preferences and their marginal willingness to pay for improved residential electricity services. The study provides an ex ante evaluation of customers' acceptance of hypothetical electricity services. According to the results, customers consider the electricity bill and the electricity mix as the two most important attributes when choosing their electricity services. Customers are willing to pay 2.2% more in the average electricity bill (an additional monthly electricity bill of KRW 1,064; USD 0.96) for a significant increase in the share of renewable energy, which is far less than the actual cost of achieving this renewable target. Therefore, it is better to maintain the current electricity mix in principle, and the renewable share should be gradually expanded instead of making a sudden change in the electricity mix. In addition, customers are willing to pay KRW 6,793 (USD 6.15) more to reduce blackouts once in a year and KRW 64/year (USD 0.06/year) to reduce a minute of each blackout. -- Highlights: •Customers' preferences for improved residential electricity services are analyzed. •Empirical setting is a sample of residents in South Korea. •The electricity bills and electricity mix are important to customers. •Increase in electricity bill of different electricity mix is considered

  16. INVESTIGATION OF ELECTROMAGNETIC FIELDS IN RESIDENTIAL AREAS

    Directory of Open Access Journals (Sweden)

    Dušan MEDVEĎ

    2017-09-01

    Full Text Available This article is devoted to investigation of impact of electromagnetic fields around the electrical equipment used in a residential area and their impact on the human body. This paper was based on sets of measurements of magnetic induction B with magnetometer and on computational simulations in ANSYS for particular appliances often used in household. The results from measurements and simulations led to setting out the recommendations for practical action in the form of elimination of harmful electromagnetic radiation.

  17. Electricity contract choices of Finnish residential customers. A choice based conjoint analysis

    Energy Technology Data Exchange (ETDEWEB)

    Rouvinen, S.; Matero, J. (Univ. of Eastern Finland, Joensuu (Finland), School of Forest Sciences), e-mail: seppo.rouvinen@uef.fi, e-mail: jukka.matero@uef.fi

    2010-07-01

    Our aim is to examine how different environmental attributes of electricity contracts affect the residential customer choices when heterogeneity in customer preferences and motivations is taken into account. The data was acquired by a mail questionnaire to random sample of Finnish people in October-November 2009 with a response rate of 38 %. In addition to conventional questions, like questions on socio-demographic and agreements of energy related statements, the discrete choice experiment (DCE) of electricity contracts was included. The choice sets in the DCE had three electricity contract alternatives with varying levels of predetermined attributes (including unit price, supplier type, frequency of power outages, energy source and CO{sub 2} emissions). In this paper, we present the findings of our DCE design. Modeling respondent choices resulted in implicit prices for various electricity contract attributes that provide guidance for green marketing strategies of electricity suppliers and energy related informational activities of public institutions. We conclude that currently the potential for increasing demand-based environmental competitiveness from the wood electricity differentiation remains limited as we did not find any significant market segment of residential customers with strong preferences for wood over other sources of electricity (including 'mixture'). (orig.)

  18. Integrating a hydrogen fuel cell electric vehicle with vehicle-to-grid technology, photovoltaic power and a residential building

    NARCIS (Netherlands)

    Robledo, C.B.; Oldenbroek, V.D.W.M.; Abbruzzese, F.; van Wijk, A.J.M.

    2018-01-01

    This paper presents the results of a demonstration project, including building-integrated photovoltaic (BIPV) solar panels, a residential building and a hydrogen fuel cell electric vehicle (FCEV) for combined mobility and power generation, aiming to achieve a net zero-energy residential building

  19. Response of residential electricity demand to price: The effect of measurement error

    International Nuclear Information System (INIS)

    Alberini, Anna; Filippini, Massimo

    2011-01-01

    In this paper we present an empirical analysis of the residential demand for electricity using annual aggregate data at the state level for 48 US states from 1995 to 2007. Earlier literature has examined residential energy consumption at the state level using annual or monthly data, focusing on the variation in price elasticities of demand across states or regions, but has failed to recognize or address two major issues. The first is that, when fitting dynamic panel models, the lagged consumption term in the right-hand side of the demand equation is endogenous. This has resulted in potentially inconsistent estimates of the long-run price elasticity of demand. The second is that energy price is likely mismeasured. To address these issues, we estimate a dynamic partial adjustment model using the Kiviet corrected Least Square Dummy Variables (LSDV) (1995) and the Blundell-Bond (1998) estimators. We find that the long-term elasticities produced by the Blundell-Bond system GMM methods are largest, and that from the bias-corrected LSDV are greater than that from the conventional LSDV. From an energy policy point of view, the results obtained using the Blundell-Bond estimator where we instrument for price imply that a carbon tax or other price-based policy may be effective in discouraging residential electricity consumption and hence curbing greenhouse gas emissions in an electricity system mainly based on coal and gas power plants. - Research Highlights: → Updated information on price elasticities for the US energy policy. → Taking into account measurement error in the price variable increase price elasticity. → Room for discouraging residential electricity consumption using price increases.

  20. Response of residential electricity demand to price: The effect of measurement error

    Energy Technology Data Exchange (ETDEWEB)

    Alberini, Anna [Department of Agricultural Economics, University of Maryland (United States); Centre for Energy Policy and Economics (CEPE), ETH Zurich (Switzerland); Gibson Institute and Institute for a Sustainable World, School of Biological Sciences, Queen' s University Belfast, Northern Ireland (United Kingdom); Filippini, Massimo, E-mail: mfilippini@ethz.ch [Centre for Energy Policy and Economics (CEPE), ETH Zurich (Switzerland); Department of Economics, University of Lugano (Switzerland)

    2011-09-15

    In this paper we present an empirical analysis of the residential demand for electricity using annual aggregate data at the state level for 48 US states from 1995 to 2007. Earlier literature has examined residential energy consumption at the state level using annual or monthly data, focusing on the variation in price elasticities of demand across states or regions, but has failed to recognize or address two major issues. The first is that, when fitting dynamic panel models, the lagged consumption term in the right-hand side of the demand equation is endogenous. This has resulted in potentially inconsistent estimates of the long-run price elasticity of demand. The second is that energy price is likely mismeasured. To address these issues, we estimate a dynamic partial adjustment model using the Kiviet corrected Least Square Dummy Variables (LSDV) (1995) and the Blundell-Bond (1998) estimators. We find that the long-term elasticities produced by the Blundell-Bond system GMM methods are largest, and that from the bias-corrected LSDV are greater than that from the conventional LSDV. From an energy policy point of view, the results obtained using the Blundell-Bond estimator where we instrument for price imply that a carbon tax or other price-based policy may be effective in discouraging residential electricity consumption and hence curbing greenhouse gas emissions in an electricity system mainly based on coal and gas power plants. - Research Highlights: > Updated information on price elasticities for the US energy policy. > Taking into account measurement error in the price variable increase price elasticity. > Room for discouraging residential electricity consumption using price increases.

  1. C-Vine copula mixture model for clustering of residential electrical load pattern data

    OpenAIRE

    Sun, M; Konstantelos, I; Strbac, G

    2016-01-01

    The ongoing deployment of residential smart meters in numerous jurisdictions has led to an influx of electricity consumption data. This information presents a valuable opportunity to suppliers for better understanding their customer base and designing more effective tariff structures. In the past, various clustering methods have been proposed for meaningful customer partitioning. This paper presents a novel finite mixture modeling framework based on C-vine copulas (CVMM) for carrying out cons...

  2. Residential consumers in the Cape Peninsula's willingness to pay for premium priced green electricity

    International Nuclear Information System (INIS)

    Oliver, Henry; Volschenk, Jako; Smit, Eon

    2011-01-01

    A number of studies have explored the willingness (i.e. stated willingness as opposed to actual willingness) of consumers to pay a premium for green electricity in developed countries. However, little is known about how this translates into an emerging economy context. This study investigates the level of willingness of residential households in South Africa's Cape Peninsula to pay a premium for electricity from renewable energy. It methodologically drew on recent contributions in the literature on norm-motivated behaviour used to identify testable factors that could influence residential consumers' willingness to pay (WTP). Interestingly, the study found a significant positive link between household income and WTP for green electricity, contrary to the findings of some previous studies. Not only are higher income households more likely to pay a premium, but typically they are also willing to pay a bigger premium. It was also further established that the view that green electricity is reliable, involvement in the recycling of waste and the belief that everyone should contribute to green electricity generation drive the WTP. - Research Highlights: →The study explored the drivers of willingness to pay (WTP) a premium for green electricity. →All the hypothesised drivers of WTP a premium were found to be significant. →Contrary to some former studies, income was found to be a good predictor of WTP and the pledged premium. →The quantum of the premium positively correlates with income levels.

  3. Electric and gas utility marketing of residential energy conservation case studies

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-05-01

    The objective of this research was to obtain information about utility conservation marketing techniques from companies actively engaged in performing residential conservation services. Many utilities currently are offering comprehensive services (audits, listing of contractors and lenders, post-installation inspection, advertising, and performing consumer research). Activities are reported for the following utilities: Niagara Mohawk Power Corporation; Tampa Electric Company; Memphis Light, Gas, and Water Division; Northern States Power-Wisconsin; Public Service Company of Colorado; Arizona Public Service Company; Pacific Gas and Electric Company; Sacramento Municipal Utility District; and Pacific Power and Light Company.

  4. Historic trends in the residential sector

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    In the OECD countries, income-driven growth in equipment ownership (heating, appliances) and home size drove household energy use up, but higher energy prices and conservation programs had a restraining effect. The results were mixed, with consumption per capita significantly lower in a few countries (United States, France), but higher in others. There was a significant decline in the intensity of space heating (30-40%) and a small decline in the intensity of electric applicances. Changes in the size and features of many appliances offset much of the improvement in technical energy efficiency. Not all of the decline in heating intensity was a result of technical change; the author estimates that about 25% was caused by change in heating behavior. In all, there were significant improvements in efficiency, but these were offset somewhat by structural change. In the Former East Bloc, there is far less residential space and amenity than in OECD countries, and efficiency of space heating and water heating is low, in part due to lake of energy pricing. Electric appliances are simple and relatively inefficient. Unlike in the OECD countries, there is little sign of improved efficiency in the 1970s and 1980s. In the LDCs, patterns of energy use, and changes in them, are very different in rural and urban areas, and vary among regions as well. Biomass is still the dominant fuel in rural areas. In urban areas, Western-like patterns of electricity (and even gas) use have emerged for appliances, cooking, and water heating among the affluent, and TV and refrigerators have become more common among the less-affluent. In many countries, especially in Southeast Asia, there has been very rapid growth in ownership of appliances. Most appliances are cheaply made and inefficient compared to similar appliances sold in the OECD countries, though there are signs of some improvement in the past decade. 16 refs., 11 figs., 9 figs

  5. Energy labeling for electric fans in Malaysia

    International Nuclear Information System (INIS)

    Mahlia, T.M.I.; Masjuki, H.H.; Taha, F.M.; Rahim, N.A.; Saidur, R.

    2005-01-01

    To reduce energy consumption in the residential sector, Malaysia Energy Commission is considering implementing energy labels for household electrical appliances including electric fans in 2005. The purpose of the energy labels is to provide the consumers a guideline to compare the size, features, price and efficiency of the appliance. This paper discusses the energy label for electric fans in this country based on Malaysian Standards developed by a technical committee that reviewed the performance of household electrical appliances. This study includes methodology for the calculation of the energy efficiency star rating and projected energy usage, performance requirements, details of the energy label and the requirements for the valid application in Malaysia. The label also can be adopted for other household electrical appliances with only slight modifications

  6. Effects of heat and electricity saving measures in district-heated multistory residential buildings

    International Nuclear Information System (INIS)

    Truong, Nguyen Le; Dodoo, Ambrose; Gustavsson, Leif

    2014-01-01

    Highlights: • We analyzed the potential for energy savings in district heated buildings. • Measures that reduce more peak load production give higher primary energy savings. • Efficient appliances increase heat demand but give net primary energy savings. • Efficient appliances give the largest net primary energy savings. - Abstract: The effects of heat and electricity saving measures in district-heated buildings can be complex because these depend not only on how energy is used on the demand side but also on how energy is provided from the supply side. In this study, we analyze the effects of heat and electricity saving measures in multistory concrete-framed and wood-framed versions of an existing district-heated building and examine the impacts of the reduced energy demand on different district heat (DH) production configurations. The energy saving measures considered are for domestic hot water reduction, building thermal envelope improvement, ventilation heat recovery (VHR), and household electricity savings. Our analysis is based on a measured heat load profile of an existing DH production system in Växjö, Sweden. Based on the measured heat load profile, we model three minimum-cost DH production system using plausible environmental and socio-political scenarios. Then, we investigate the primary energy implications of the energy saving measures applied to the two versions of the existing building, taking into account the changed DH demand, changed cogenerated electricity, and changed electricity use due to heat and electricity saving measures. Our results show that the difference between the final and primary energy savings of the concrete-framed and wood-framed versions of the case-study building is minor. The primary energy efficiency of the energy saving measures depends on the type of measure and on the composition of the DH production system. Of the various energy saving measures explored, electricity savings give the highest primary energy savings

  7. Choosing Wood Burning Appliances

    Science.gov (United States)

    Information to assist consumers in choosing a wood burning appliance, including types of appliances, the differences between certified and non-certified appliances, and alternative wood heating options.

  8. Residential demand response reduces air pollutant emissions on peak electricity demand days in New York City

    International Nuclear Information System (INIS)

    Gilbraith, Nathaniel; Powers, Susan E.

    2013-01-01

    Many urban areas in the United States have experienced difficulty meeting the National Ambient Air Quality Standards (NAAQS), partially due to pollution from electricity generating units. We evaluated the potential for residential demand response to reduce pollutant emissions on days with above average pollutant emissions and a high potential for poor air quality. The study focused on New York City (NYC) due to non-attainment with NAAQS standards, large exposed populations, and the existing goal of reducing pollutant emissions. The baseline demand response scenario simulated a 1.8% average reduction in NYC peak demand on 49 days throughout the summer. Nitrogen oxide and particulate matter less than 2.5 μm in diameter emission reductions were predicted to occur (−70, −1.1 metric tons (MT) annually), although, these were not likely to be sufficient for NYC to meet the NAAQS. Air pollution mediated damages were predicted to decrease by $100,000–$300,000 annually. A sensitivity analysis predicted that substantially larger pollutant emission reductions would occur if electricity demand was shifted from daytime hours to nighttime hours, or the total consumption decreased. Policies which incentivize shifting electricity consumption away from periods of high human and environmental impacts should be implemented, including policies directed toward residential consumers. - Highlights: • The impact of residential demand response on air emissions was modeled. • Residential demand response will decrease pollutant emissions in NYC. • Emissions reductions occur during periods with high potential for poor air quality. • Shifting demand to nighttime hours was more beneficial than to off-peak daytime hours

  9. Energy in the residential building. Electricity, heat, e-mobility. 2. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Schwarzburger, Heiko

    2017-01-01

    Photovoltaics, heat pumps and fuel cells offer enormous potential for sustainable energy supply in residential buildings. Solar thermal energy and wood-fired boilers also play an important role in refurbishment. Due to the wide range of possible combinations, the wishes of building owners and homeowners for an ecologically and economically individually adapted energy concept can be fulfilled accurately. This book provides you with a holistic approach to the residential building and its supply of electricity, heat and water. All processes that play a role in the house's energy consumption are examined in their entirety for their potentials and potential savings. The author analyses and describes in detail the resources of buildings and their surroundings - and how they can be used for a truly independent supply. The focus is on reducing energy consumption and costs, the generation and supply of energy from renewable sources and energy storage - considered in new construction and modernisation. The supply of water is also dealt with if it touches on energy issues. The author draws attention to standards and regulations and gives practical advice for planning and installation. The focus is on the so-called sector coupling: electricity from the sun, wind and hydrogen is used to supply electrical consumers in the home, charging technology for electric vehicles, hot water and heating. The time of the boilers and combustion engines has elapsed. Clean electricity and digital controls - power and intelligence - determine the regenerative building technology. [de

  10. Disposal machine using a hydraulic shovel loader for waste home electric appliances; Yuatsu shoberunado wo katsuyoshita haikaden shori kikai

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-09-25

    This paper presents a disposal machine system developed by Hitachi Kenki Co. for waste home appliances. EX60 disposal machine and 2-axis shear shredder were developed as work machines for volume reduction and efficient disposal of waste home appliances. The shredder with rotary cutters is featured by superior crunch performance and efficient shredding of waste home appliances, and can crash not only waste home appliances but also various objects such as bulky waste, waste plastics and waste tire for passenger cars at crash torques from 7000 to 12000kgf{center_dot}m. The shredder is featured by superior mobility and easy operability by self-running and full-hydraulic driving, low- noise engine, and noise/vibration reduction by low-speed large torque hydraulic motor. EX60 disposal machine has clamp fixing waste home appliances, and a grapple for disassembling and classification, and can efficiently disassemble and classify 4 kinds of waste home appliances and other wastes only by itself. 12 figs., 3 tabs.

  11. Optimized Energy Management of a Single-House Residential Micro-Grid With Automated Demand Response

    DEFF Research Database (Denmark)

    Anvari-Moghaddam, Amjad; Monsef, Hassan; Rahimi-Kian, Ashkan

    2015-01-01

    In this paper, an intelligent multi-objective energy management system (MOEMS) is proposed for applications in residential LVAC micro-grids where households are equipped with smart appliances, such as washing machine, dishwasher, tumble dryer and electric heating and they have the capability...

  12. Electric vehicles in low voltage residential grid: a danish case study

    DEFF Research Database (Denmark)

    Pillai, Jayakrishnan Radhakrishna; Huang, Shaojun; Thøgersen, Paul

    2012-01-01

    Electric Vehicles (EVs) have gained large interest in the energy sector as a carrier to support clean transportation and green electricity. The potential to use battery storages of electric vehicles as a sink for excess electricity that may result from large integration of wind power, especially...... in countries like Denmark, is widely discussed and promoted. However, the wide-spread adoption of EVs requires the provision of intelligent grid and EV charging infrastructure. To analyse and understand the amount of EVs that could be integrated in the local distribution grids, within its existing capabilities......, is absolutely essential for the system operators to plan and implement the levels of grid reinforcement and intelligence required. This paper investigates the local grid limitations to accommodate large amount of EVs of sizable power ratings in residential areas. The case study applied in this paper uses...

  13. 24 CFR 3280.807 - Fixtures and appliances.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Fixtures and appliances. 3280.807... Fixtures and appliances. (a) Electrical materials, devices, appliances, fittings, and other equipment... fasten appliances when the manufactured home is in transit. (See § 3280.809.) (b) Specifically listed...

  14. Module Embedded Micro-inverter Smart Grid Ready Residential Solar Electric System

    Energy Technology Data Exchange (ETDEWEB)

    Agamy, Mohammed [GE Global Research Center, Niskayuna, NY (United States)

    2015-10-27

    The “Module Embedded Micro-inverter Smart Grid Ready Residential Solar Electric System” program is focused on developing innovative concepts for residential photovoltaic (PV) systems with the following objectives: to create an Innovative micro-inverter topology that reduces the cost from the best in class micro-inverter and provides high efficiency (>96% CEC - California Energy Commission), and 25+ year warranty, as well as reactive power support; integrate micro-inverter and PV module to reduce system price by at least $0.25/W through a) accentuating dual use of the module metal frame as a large area heat spreader reducing operating temperature, and b) eliminating redundant wiring and connectors; and create micro-inverter controller handles smart grid and safety functions to simplify implementation and reduce cost.

  15. A Hybrid dasymetric and machine learning approach to high-resolution residential electricity consumption modeling

    Energy Technology Data Exchange (ETDEWEB)

    Morton, April M [ORNL; Nagle, Nicholas N [ORNL; Piburn, Jesse O [ORNL; Stewart, Robert N [ORNL; McManamay, Ryan A [ORNL

    2017-01-01

    As urban areas continue to grow and evolve in a world of increasing environmental awareness, the need for detailed information regarding residential energy consumption patterns has become increasingly important. Though current modeling efforts mark significant progress in the effort to better understand the spatial distribution of energy consumption, the majority of techniques are highly dependent on region-specific data sources and often require building- or dwelling-level details that are not publicly available for many regions in the United States. Furthermore, many existing methods do not account for errors in input data sources and may not accurately reflect inherent uncertainties in model outputs. We propose an alternative and more general hybrid approach to high-resolution residential electricity consumption modeling by merging a dasymetric model with a complementary machine learning algorithm. The method s flexible data requirement and statistical framework ensure that the model both is applicable to a wide range of regions and considers errors in input data sources.

  16. Designing, Building and Controlling of Home Appliances Unit Using PC

    Directory of Open Access Journals (Sweden)

    Saleh Ben Safar

    2017-12-01

    Full Text Available Smart home is a residential building that is usually new or modern equipped with necessary tools and wiring that enable its occupants to control a number of electrical devices and several household appliances through a suitable software. Recently, the development of home automation systems is accelerating rapidly as a result of the rapid intersection of modern technologies. Here we are talking about systems for home communication networks as well as entertainment, security, convenience, etc. These systems are controlled by sending signals through wires distributed throughout the house or Through wireless means to programmable keys or devices so that they understand these commands and deal with them as desired. In this paper, I will discuss how to design the circuit with appropriate components, build it in Printed Circuit Board and connect it to a personal computer by using programmable language in order to control all home appliances by just one click. 

  17. Controlling the demand for electricity: strategies and challenges in the residential sector of the OECD countries

    International Nuclear Information System (INIS)

    Lebot, B.

    2003-01-01

    By reinforcing policies to improve the energy efficiency of household appliances (particularly by rating the efficiency of each appliance as a minimum of its overall cost from 2005 onwards), the member countries of the IEA are in a position to reduce their annual CO 2 emissions by approximately 322 million tonnes (Mt) by 2010, compared to what they would have obtained using current policies. In 2030, this same policy will make it possible to achieve an annual saving of 1 110 TWh in the consumption of electricity, (572 Mt of CO 2 each year). This measure alone will meet 30% of the objectives of the member countries of the IEA under the Kyoto agreements concerning climatic change. These reductions can be obtained at a negative cost for society as the additional cost generated by improvements in energy efficiency is offset by savings made in operating costs during the life of the appliance. Thus, in the United States, each tonne of CO 2 saved in this way in 2020 will generate $65 for society. In Europe, every tonne of CO 2 saved will generate a gain of euros 169 (the difference being accounted for by the higher cost of electricity and by lower energy efficiency standards currently existing in Europe). It is possible to make major savings in all regions of the OECD, despite the vast diversity of the various situations of the countries. In the member countries of the IEA, the policies in place have already demonstrated their economic effectiveness in reducing demand for energy and greenhouse gas emissions. Up to 2000, they made it possible to reduce greenhouse gas emissions by approximately 46 Mt of CO 2 each year. These policies will contribute to reducing emissions by 126 Mt of CO 2 each year up to 2010. International co-operation offers real advantages in the deployment of policies for controlling the demand for energy by households. Manufacturers, consumers and governments all benefit from greater transparency in the marketplace, improved comparisons of test methods

  18. The long-run price sensitivity dynamics of industrial and residential electricity demand: The impact of deregulating electricity prices

    International Nuclear Information System (INIS)

    Adom, Philip Kofi

    2017-01-01

    This study examines the demand-side of Ghana's electricity sector. We test two important related hypotheses: (1) deregulation of electricity price does not promote energy conservation, and (2) demand-price relationship is not an inverted U-shaped. The Stock and Watson dynamic OLS is used to address the so-called second-order bias. The result showed that, deregulation of electricity price in Ghana has induced behaviours that are more consistent with energy conservation improvements. The demand-price relationship is an inverted U, which suggests that there is a price range that end-users can tolerate further price rise and still increase their consumption of electricity. However, the degree of price tolerability is higher for residential consumers than industrial consumers. The simulation results showed that, further economic growth is likely to compromise energy conservation but more in the industrial sector than the residential sector. On the other hand, future crude oil price is likely to deteriorate energy conservation in the initial years after 2016, but this trend is likely to reverse after the year 2020. Pricing mechanisms are potent to induce energy conservation but inadequate. The results suggest that they should be complemented with other stringent policies such as a mandatory energy reduction policy, investment in renewables, and personalization of energy efficiency programs. - Highlights: • Studies the demand-side of the electricity sector • Deregulating electricity price promotes energy conservation • Demand-price relationship is an inverted U-shaped • Pricing policies should be combined with other energy mandatory reduction policies

  19. Did residential electricity rates fall after retail competition? A dynamic panel analysis

    International Nuclear Information System (INIS)

    Swadley, Adam; Yücel, Mine

    2011-01-01

    A key selling point for the restructuring of electricity markets was the promise of lower prices. There is not much consensus in earlier studies on the effects of electricity deregulation in the U.S., particularly for residential customers. Part of the reason for not finding a consistent link with deregulation and lower prices was that the removal of transitional price caps led to higher prices. In addition, the timing of the removal of price caps coincided with rising fuel prices, which were passed on to consumers in a competitive market. Using a dynamic panel model, we analyze the effect of participation rates, fuel costs, market size, a rate cap and switch to competition for 16 states and the District of Columbia. We find that an increase in participation rates, price controls, a larger market, and high shares of hydro in electricity generation lower retail prices, while increases in natural gas and coal prices increase rates. We also find that retail competition makes the market more efficient by lowering the markup of retail prices over wholesale costs. The effects of a competitive retail electricity market are mixed across states, but generally appear to lower prices in states with high participation rates. - Highlights: ► We analyze the effects of retail competition in electricity markets on residential retail prices. ► Analysis carried out using a dynamic panel model; monthly data for 17 U.S. states. ► More customer participation and larger market lead to lower prices. ► Higher fuel costs increase retail prices, but with a lag. ► Retail competition leads to a more efficient electricity market.

  20. Estimating short and long-term residential demand for electricity. New evidence from Sri Lanka

    International Nuclear Information System (INIS)

    Athukorala, P.P.A Wasantha; Wilson, Clevo

    2010-01-01

    This study investigates the short-run dynamics and long-run equilibrium relationship between residential electricity demand and factors influencing demand - per capita income, price of electricity, price of kerosene oil and price of liquefied petroleum gas - using annual data for Sri Lanka for the period, 1960-2007. The study uses unit root, cointegration and error-correction models. The long-run demand elasticities of income, own price and price of kerosene oil (substitute) were estimated to be 0.78, - 0.62, and 0.14 respectively. The short-run elasticities for the same variables were estimated to be 0.32, - 0.16 and 0.10 respectively. Liquefied petroleum (LP) gas is a substitute for electricity only in the short-run with an elasticity of 0.09. The main findings of the paper support the following (1) increasing the price of electricity is not the most effective tool to reduce electricity consumption (2) existing subsidies on electricity consumption can be removed without reducing government revenue (3) the long-run income elasticity of demand shows that any future increase in household incomes is likely to significantly increase the demand for electricity and (4) any power generation plans which consider only current per capita consumption and population growth should be revised taking into account the potential future income increases in order to avoid power shortages in the country. (author)

  1. Estimating short and long-term residential demand for electricity. New evidence from Sri Lanka

    Energy Technology Data Exchange (ETDEWEB)

    Athukorala, P.P.A Wasantha; Wilson, Clevo [School of Economics and Finance, Queensland University of Technology, Brisbane (Australia)

    2010-09-15

    This study investigates the short-run dynamics and long-run equilibrium relationship between residential electricity demand and factors influencing demand - per capita income, price of electricity, price of kerosene oil and price of liquefied petroleum gas - using annual data for Sri Lanka for the period, 1960-2007. The study uses unit root, cointegration and error-correction models. The long-run demand elasticities of income, own price and price of kerosene oil (substitute) were estimated to be 0.78, - 0.62, and 0.14 respectively. The short-run elasticities for the same variables were estimated to be 0.32, - 0.16 and 0.10 respectively. Liquefied petroleum (LP) gas is a substitute for electricity only in the short-run with an elasticity of 0.09. The main findings of the paper support the following (1) increasing the price of electricity is not the most effective tool to reduce electricity consumption (2) existing subsidies on electricity consumption can be removed without reducing government revenue (3) the long-run income elasticity of demand shows that any future increase in household incomes is likely to significantly increase the demand for electricity and (4) any power generation plans which consider only current per capita consumption and population growth should be revised taking into account the potential future income increases in order to avoid power shortages in the country. (author)

  2. 1992-1993 Bonneville Appliance Efficiency Program: Showerhead evaluation. Volume I - report

    Energy Technology Data Exchange (ETDEWEB)

    Warwick, W.M.

    1995-01-01

    The Bonneville Power Administration (Bonneville) provides wholesale electric power to over 100 retail distribution utilities in the Pacific Northwest. Bonneville is faced with meeting growing loads from these utilities. It acquires conservation as one means of meeting this load growth. Bonneville has offered a variety of conservation programs since 1980. Efficient showerheads have been a feature in residential conservation programs ever since. Bonneville launched the Residential Appliance Efficiency Program to focus on water-heater energy conservation opportunities in 1992. The Residential Appliance Efficiency Program consists of two parts, a water-heater efficiency program, and a hot-water efficiency program. This report evaluates the savings and costs of the first two years of the showerhead portion of the Residential Appliance Efficiency Program (the showerhead program). Although it is not a formal evaluation of the program limited to implementation or a {open_quotes}process{close_quotes} evaluation, observations about program design and implementation are included as appropriate. Results of this evaluation are limited to program participants within the Bonneville service territory.

  3. The electric tariff in the residential sector; Tarificacion electrica en el sector residencial

    Energy Technology Data Exchange (ETDEWEB)

    Sheinbaum Pardo, Claudia [Instituto de Ingenieria, Universidad Nacional Autonoma de Mexico (UNAM), Mexico, D. F. (Mexico)

    1997-12-31

    The main objective of this paper is to make an historical revision and analyze the current condition of the electric tariffs in the Mexican residential sector and ask ourselves if the equalization of tariffs generates the possibility that the entire population has access to the electricity service. The document is divided into three parts. The first one presents the history and the tendencies of the tariffs in the domestic sector in Mexico since 1973 until 1996 and the current tariff structure. The second one describes the characteristics of the residential users and mention is made of how the increment of the electric tariffs would affect the various population sectors. The last part of this paper presents some tariff criteria, that take into account energy conservation measures [Espanol] El objetivo principal de este trabajo es hacer una revision historica y analizar la situacion actual de las tarifas electricas en el sector residencial mexicano y preguntarnos si la igualdad de tarifas genera la posibilidad de que toda la poblacion tenga acceso al servicio electrico. El documento se divide en tres partes. La primera presenta la historia y tendencias de las tarifas del sector domestico en Mexico desde 1973 hasta 1996 y la estructura tarifaria actual. La segunda describe las caracteristicas de los usuarios residenciales y se menciona como afectaria el incremento de las tarifas electricas a los distintos sectores de la poblacion. La ultima parte de este trabajo presenta algunos criterios de tarificacion, que toman en cuenta medidas de ahorro de energia

  4. Paper de recherche no. 28 Bis. Can negotiated agreements replace efficiency standards as an instrument for transforming the electrical appliance market?; Cahier de recherche no. 28. Les accords negocies peuvent-ils remplacer les normes de performance pour la transformation du marche de l'electromenager

    Energy Technology Data Exchange (ETDEWEB)

    Menanteau, Ph.

    2002-03-01

    Without reinforced energy saving policies, residential consumption of electricity will increase sharply over the next twenty years, in particular as a result of expected growth in the specific uses of electricity. The main problem is not a lack of energy efficient technologies, which do indeed exist for electrical appliances, but one of slow diffusion of existing technologies due to the weakness of the price signal and the purchasing behaviour of consumers. In association with energy labelling, minimum efficiency performance standards have proved to be very effective in stimulating technological progress and organizing market transformation. But standards also suffer from long and often difficult implementation periods because of the resistance of the industrial sector. For manufacturers, similar results could be obtained more easily and more rapidly with voluntary agreements because they introduce flexibility margins in the achievement of commitments. This paper analyses the specific advantages of voluntary agreements for improving energy efficiency in the domestic appliances sector. We conclude that voluntary agreements may be an effective instrument for market transformation in certain conditions, but the alternative of regulatory measures must remain a credible, realistic threat if voluntary agreements are to have a really significant impact on performance improvement. (author)

  5. Industrial and residential electricity demand dynamics in Japan: How did price and income elasticities evolve from 1989 to 2014?

    International Nuclear Information System (INIS)

    Wang, Nan; Mogi, Gento

    2017-01-01

    This study estimates the price and income elasticities of industrial and residential electricity demand in Japan with the annual data from 1989 to 2014. A time varying parameter (TVP) model with the Kalman filter is applied to monitor the evolution of consumer behaviors in the “post-bubble” period given the exogenous shock (financial crisis in 2008) and the structural breaks (electricity deregulation and Fukushima Daiichi crisis). The TVP model can provide a robust estimation of elasticities and can detect the outliers and the structural breaks. The results suggest that both industrial and residential consumers become less sensitive to price after the electricity deregulation and the financial crisis, and more sensitive to price after the Fukushima Daiichi crisis. Especially the industrial sector is less sensitive to price after the retail deregulation. By contrast, the income elasticities of industrial and residential sector consumers are stable during the examined period. Results also indicate that a negative relationship exists between the price elasticity of electricity demand and the price level of electricity after the electric sector deregulation. Some insights on the further electric sector reform and the environmental taxation in Japan are also provided. - Highlights: • A time varying parameter model is calculated with the Kalman filter. • Income elasticities are stable while price elasticities are time-varying. • Industrial sector is less sensitive to price change than residential sector. • Negative relationship between price elasticity and price level is found.

  6. Wisdom Appliance Control System

    Science.gov (United States)

    Hendrick; Jheng, Jyun-Teng; Tsai, Chen-Chai; Liou, Jia-Wei; Wang, Zhi-Hao; Jong, Gwo-Jia

    2017-07-01

    Intelligent appliances wisdom involves security, home care, convenient and energy saving, but the home automation system is still one of the core unit, and also using micro-processing electronics technology to centralized and control the home electrical products and systems, such as: lighting, television, fan, air conditioning, stereo, it composed of front-controller systems and back-controller panels, user using front-controller to control command, and then through the back-controller to powered the device.

  7. Economic analysis of second use electric vehicle batteries for residential energy storage and load-levelling

    International Nuclear Information System (INIS)

    Heymans, Catherine; Walker, Sean B.; Young, Steven B.; Fowler, Michael

    2014-01-01

    The reuse of Li-ion EV batteries for energy storage systems (ESS) in stationary settings is a promising technology to support improved management of demand and supply of electricity. In this paper, MatLAB simulation of a residential energy profile and regulated cost structure is used to analyze the feasibility of and cost savings from repurposing an EV battery unit for peak-shifting. in situ residential energy storage can contribute to the implementation of a smart grid by supporting the reduction of demand during typical peak use periods. Use of an ESS increases household energy use but potentially improves economic effectiveness and reduces greenhouse gas emissions. The research supports the use of financial incentives for Li-ion battery reuse in ESS, including lower energy rates and reduced auxiliary fees. - Highlights: • EV Li-ion batteries can be reused in stationary energy storage systems (ESS). • A single ESS can shift 2 to 3 h of electricity used in a house. • While energy use increases, potential economic and environmental effectiveness improve. • ESS supports smart grid objectives. • Incentives like reduced fees are needed to encourage implementation of Li-ion battery ESS

  8. Meeting the Electrical Energy Needs of a Residential Building with a Wind-Photovoltaic Hybrid System

    Directory of Open Access Journals (Sweden)

    Mohammad Hosein Mohammadnezami

    2015-03-01

    Full Text Available A complete hybrid system including a photovoltaic cell, a wind turbine, and battery is modeled to determine the best approach for sizing the system to meet the electrical energy needs of a residential building. In evaluating system performance, the city of Tehran is used as a case study. Matlab software is used for analyzing the data and optimizing the system for the given application. Further, the cost of the system design is investigated, and shows that the electrical cost of the hybrid system in Tehran is 0.62 US$/kWh, which is 78% less expensive than a wind turbine system and 34% less expensive than a photovoltaic system.

  9. An analysis of a demand charge electricity grid tariff in the residential sector

    International Nuclear Information System (INIS)

    Stokke, A. V.; Doorman, G.L.; Ericson, T.

    2010-01-01

    This paper analyzes the demand response from residential electricity consumers to a demand charge grid tariff. The tariff charges the maximum hourly peak consumption in each of the winter months Dec, Jan, and Feb, thus giving incentives to reduce peak consumption. We use hourly electricity consumption data from 443 households, as well as data on their grid and power prices, the local temperature, wind speed, and hours of daylight. The panel data set is analyzed with a fixed effects regression model. The estimates indicate average demand reductions up to 0.37 kWh/h per household in response to the tariff. This is on average a 5% reduction, with a maximum reduction of 12% in hour 8 in Dec. The consumers did not receive any information on their continuous consumption or any reminders when the tariff was in effect. It is likely that the consumption reductions would have been even higher with more information to the consumers.

  10. Wright tariffs in the Spanish electricity industry: the case of residential consumption

    International Nuclear Information System (INIS)

    Castro-Rodriguez, F.

    1999-01-01

    In this paper a capacity price model is developed for the Spanish electricity industry which allows the presentation of the Spanish utilization level tariffs as an example of duration tariffs (Wright tariffs) when duration is approximated by the ratio of consumption to power used. Using this model and data on the residential consumption of electricity, several optimal two-part tariffs are computed, considering different hypothesis on the configuration of the generating equipment. It has been found that the optimal tariff maintaining universal service increases welfare if the generating equipment and the output assignment to the different technologies are taken as given. Furthermore, if the regulator is concerned not only with efficiency, but also with distributive issues, then welfare losses associated with the existing regulatory regime are even larger

  11. A Cost-Effective Electric Vehicle Charging Method Designed For Residential Homes with Renewable Energy

    Science.gov (United States)

    Lie, T. T.; Liang, Xiuli; Haque, M. H.

    2015-03-01

    Most of the electrical infrastructure in use around the world today is decades old, and may be illsuited to widespread proliferation of personal Electric Vehicles (EVs) whose charging requirements will place increasing strain on grid demand. In order to reduce the pressure on the grid and taking benefits of off peak charging, this paper presents a smart and cost effective EV charging methodology for residential homes equipped with renewable energy resources such as Photovoltaic (PV) panels and battery. The proposed method ensures slower battery degradation and prevents overcharging. The performance of the proposed algorithm is verified by conducting simulation studies utilizing running data of Nissan Altra. From the simulation study results, the algorithm is shown to be effective and feasible which minimizes not only the charging cost but also can shift the charging time from peak value to off-peak time.

  12. A nonlinear approach to modelling the residential electricity consumption in Ethiopia

    International Nuclear Information System (INIS)

    Gabreyohannes, Emmanuel

    2010-01-01

    In this paper an attempt is made to model, analyze and forecast the residential electricity consumption in Ethiopia using the self-exciting threshold autoregressive (SETAR) model and the smooth transition regression (STR) model. For comparison purposes, the application was also extended to standard linear models. During the empirical presentation of both models, significant nonlinear effects were found and linearity was rejected. The SETAR model was found out to be relatively better than the linear autoregressive model in out-of-sample point and interval (density) forecasts. Results from our STR model showed that the residual variance of the fitted STR model was only about 65.7% of that of the linear ARX model. Thus, we can conclude that the inclusion of the nonlinear part, which basically accounts for the arrival of extreme price events, leads to improvements in the explanatory abilities of the model for electricity consumption in Ethiopia. (author)

  13. A nonlinear approach to modelling the residential electricity consumption in Ethiopia

    Energy Technology Data Exchange (ETDEWEB)

    Gabreyohannes, Emmanuel [Ethiopian Civil Service College, P.O.Box 5648, Addis Ababa (Ethiopia)

    2010-05-15

    In this paper an attempt is made to model, analyze and forecast the residential electricity consumption in Ethiopia using the self-exciting threshold autoregressive (SETAR) model and the smooth transition regression (STR) model. For comparison purposes, the application was also extended to standard linear models. During the empirical presentation of both models, significant nonlinear effects were found and linearity was rejected. The SETAR model was found out to be relatively better than the linear autoregressive model in out-of-sample point and interval (density) forecasts. Results from our STR model showed that the residual variance of the fitted STR model was only about 65.7% of that of the linear ARX model. Thus, we can conclude that the inclusion of the nonlinear part, which basically accounts for the arrival of extreme price events, leads to improvements in the explanatory abilities of the model for electricity consumption in Ethiopia. (author)

  14. Okanagan indoor wood burning appliance inventory survey

    International Nuclear Information System (INIS)

    2001-01-01

    A survey was conducted to determine the usage and nature of wood burning appliances used by residents in British Columbia's Okanagan region. The objective was to better understand this source of air quality concern and to facilitate strategic planning, guidelines and legislation. The survey also provides a baseline to track the effectiveness of any reduction strategies. It identifies the different types of wood burning appliances used in the community and presents residential options about potential bylaws to protect air quality. The receptivity of households to switch to more efficient wood burning appliances was also examined. The survey completes a portion of an overall emissions inventory for the Okanagan Valley. Environment Canada uses the particulate loading results to model the air quality in the airshed. Results showed that approximately 21 per cent of the households in the Okanagan use indoor wood burning appliances, and burn an average of 2.3 cords of wood each year. Only 11 per cent of the appliances are considered to have advanced burning technology. It is projected that the use of wood burning appliances in the Okanagan will increase by 5 to 7 per cent in the next 2 years. Most residents have good burning habits, but some improvements can still be made. Many residents are considering exchanging old wood burning appliances for clean burning technology appliances for environmental and health reasons. Most households would support a bylaw to control nuisance amounts of smoke from wood burning appliances. 20 tabs., 5 figs

  15. The Private Net Benefits of Residential Solar PV: The Role of Electricity Tariffs, Tax Incentives and Rebates

    OpenAIRE

    Severin Borenstein

    2015-01-01

    With dramatic declines in the cost of solar PV technology over the last 5 years, the electricity industry is in the midst of discussions about whether to use this low-polluting renewable energy source in grid-scale generation or in distributed generation (DG), mostly with rooftop solar PV. California has led the growth in DG solar in the U.S. I use 2007 to early 2014 residential data from Pacific Gas & Electric – the utility with largest number of residential solar customers in the U.S. – to ...

  16. Modelling weather effects for impact analysis of residential time-of-use electricity pricing

    International Nuclear Information System (INIS)

    Miller, Reid; Golab, Lukasz; Rosenberg, Catherine

    2017-01-01

    Analyzing the impact of pricing policies such as time-of-use (TOU) is challenging in the presence of confounding factors such as weather. Motivated by a lack of consensus and model selection details in prior work, we present a methodology for modelling the effect of weather on residential electricity demand. The best model is selected according to explanatory power, out-of-sample prediction accuracy, goodness of fit and interpretability. We then evaluate the effect of mandatory TOU pricing in a local distribution company in southwestern Ontario, Canada. We use a smart meter dataset of over 20,000 households which is particularly suited to our analysis: it contains data from the summer before and after the implementation of TOU pricing in November 2011, and all customers transitioned from tiered rates to TOU rates at the same time. We find that during the summer rate season, TOU pricing results in electricity conservation across all price periods. The average demand change during on-peak and mid-peak periods is −2.6% and −2.4% respectively. Changes during off-peak periods are not statistically significant. These TOU pricing effects are less pronounced compared to previous studies, underscoring the need for clear, reproducible impact analyses which include full details about the model selection process. - Highlights: • We study models for the effect of weather on residential electricity demand. • We evaluate the effect of mandatory TOU pricing in a local distribution company in Ontario, Canada. • We find the effect of TOU pricing to be less pronounced compared to previous studies.

  17. Assessing incentive contracts for reducing residential electricity consumption: new experimental methods for new results

    International Nuclear Information System (INIS)

    Frachet, Laure

    2013-01-01

    Facing economic, political and environmental stakes, electricity providers are nowadays developing incentive tools, in order to reduce consumer's demand, particularly during peak demand periods. For residential customers, these tools can be tariffs (dynamic pricing of time-of-use tariffs), or informative devices or services (feedbacks on historical or real-time consumption, given on various media). They might go along with automation systems that can help cutting of some electric devices when needed. In order to evaluate the capacity of these settings among their customers, electricity utilities are developing quite a few studies, which are mainly field experiment often called pilots. During these pilots, demand response tools are implemented on a population sample. These long and expensive studies lid to quantitative and qualitative analysis. We have compiled about 40 of them and extract from this survey some generalizable teachings. We have shown what these results were and highlighted pilot programs' methodological limits. In order to propose a substitute to these heavy experimentations, we assessed the capacity or experimental economics. This relatively new discipline's objective is to evaluation the efficiency of institutions, like markets, but also to study what animate economic agents' behaviour, e.g. preferences, beliefs, cognitive biases, willingness to pay... We were also able to elaborate an experimental protocol dedicated to the evaluation of some demand response contracts' acceptability. The results collected during 14 experimental sessions gave us some innovative clues and insight on these contracts acceptability. But, beyond these results, we have demonstrated that even if experimental economics can't obviously be a substitute for field experiments, it can represent an interesting exploratory methodology. To sum up the experimental economics can take part of residential customers' behaviour understanding, performing

  18. Cooking Appliances Using High-Frequency Heating

    OpenAIRE

    木村, 秀行; Hideyuki, KIMURA; (株)日立製作所機械研究所

    2007-01-01

    We have produced a guide suitable for people with no technical knowledge of cooking appliances that use high-frequency heating. In general, cooking appliances that use an electric heat source are popular since, they are simple to use because the offer easy heat control, are safe because they do not have naked flames, and do not make kitchens dirty because there is no exhaust. In recent years, high-efficiency cooking appliances using high-frequency heating technology have surged in popularity....

  19. An exploratory analysis of California residential customer response to critical peak pricing of electricity

    International Nuclear Information System (INIS)

    Herter, Karen; McAuliffe, Patrick; Rosenfeld, Arthur

    2007-01-01

    This paper summarizes the results from an exploratory analysis of residential customer response to a critical peak pricing (CPP) experiment in California, in which 15 times per year participating customers received high price signals dispatched by a local electricity distribution company. The high prices were about three times the on-peak price for the otherwise applicable time-of-use rate. Using hourly load data collected during the 15-month experiment, we find statistically significant load reduction for participants both with and without automated end-use control technologies. During 5-h critical peak periods, participants without control technology used up to 13% less energy than they did during normal peak periods. Participants equipped with programmable communicating thermostats used 25% and 41% less for 5 and 2h critical events, respectively. Thus, this paper offers convincing evidence that the residential sector can provide substantial contributions to retail demand response, which is considered a potential tool for mitigating market power, stabilizing wholesale market prices, managing system reliability, and maintaining system resource adequacy. (author)

  20. A MEMS AC current sensor for residential and commercial electricity end-use monitoring

    International Nuclear Information System (INIS)

    Leland, E S; Wright, P K; White, R M

    2009-01-01

    This paper presents a novel prototype MEMS sensor for alternating current designed for monitoring electricity end-use in residential and commercial environments. This new current sensor design is comprised of a piezoelectric MEMS cantilever with a permanent magnet mounted on the cantilever's free end. When placed near a wire carrying AC current, the magnet is driven sinusoidally, producing a voltage in the cantilever proportional to the current being measured. Analytical models were developed to predict the applicable magnetic forces and piezoelectric voltage output in order to guide the design of a sensor prototype. This paper also details the fabrication process for this sensor design. Released piezoelectric MEMS cantilevers have been fabricated using a four-mask process and aluminum nitride as the active piezoelectric material. Dispenser-printed microscale composite permanent magnets have been integrated, resulting in the first MEMS-scale prototypes of this current sensor design

  1. Unleashing Flexibility from Electric Boilers and Heat Pumps in Danish Residential Distribution Network

    DEFF Research Database (Denmark)

    Sinha, Rakesh; Bak-Jensen, Birgitte; Pillai, Jayakrishnan Radhakrishna

    2018-01-01

    and thereby improving its techno-economic efficiency. The data used for the evaluation are also from the real household sites in Denmark provided by the district heating utility. Focus is on the low-voltage grid, and that’s very relevant since many doesn’t expect any flexibility from that voltage level. Study...... this model is compared to responses from an average model of the hot water storage tank to evaluate the benefit of the more detailed model. Finally, analysis on consumption patterns of electrical and thermal loads in residential buildings in Northern Jutland, Denmark, are used for analysis of the system...... and use of thermal units as flexible consumer loads in the low voltage (LV) distribution network grid. The models of EB and HP with storage tank are briefly discussed in relation to the actual control and flexibility based on grid condition and status of storage tank temperature or position...

  2. Massive coordination of residential embedded electricity generation and demand response using the PowerMatcher approach

    International Nuclear Information System (INIS)

    Kamphuis, I.G.; Hommelberg, M.P.F.; Warmer, C.J.; Kok, J.K.

    2007-01-01

    Different driving forces push the electricity production towards decentralization. The projected increase of distributed power generation on the residential level with an increasing proportion of intermittent renewable energy resources poses problems for continuously matching the energy balance when coordination takes place centrally. On the other hand, new opportunities arise by intelligent clustering of generators and demand in so-called Virtual Power Plants. Part of the responsibility for new coordination mechanisms, then, has to be laid locally. To achieve this, the current electricity infrastructure is expected to evolve into a network of networks (including ICT (Information and Communication Technology)-networks), in which all system parts communicate with one another, are aware of each other's context and may influence each other. In this paper, a multi-agent systems approach, using price signal-vectors from an electronic market is presented as an appropriate technology needed for massive control and coordination tasks in these future electricity networks. The PowerMatcher, a market-based control concept for supply and demand matching (SDM) in electricity networks, is discussed. The results within a simulation study show the ability to raise the simultaneousness of electricity production and consumption within (local) control clusters with cogeneration and heat-pumps by exchanging price signals and coordinated allocation using market algorithms. The control concept, however, can also be applied in other business cases like reduction of imbalance cost in commercial portfolios or virtual power plant operators, utilizing distributed generators. Furthermore, a PowerMatcher-based field test configuration with 15 Stirling-engine powered micro-CHP's is described, which is currently in operation within a field test in the Netherlands

  3. Survey of residential magnetic field sources interim report

    International Nuclear Information System (INIS)

    Dunlap, J.H.; Zaffanella, L.E.; Johnson, G.B.

    1993-01-01

    The Electric Power Research Institute (EPRI) has conducted a nationwide survey to collect engineering data on the sources and the levels of power frequency magnetic fields that exist in residences. The survey involves measurements at approximately 1,000 residences randomly selected in the service area of 25 utilities. The information in this paper contains data from approximately 700 homes measured. The goals of the survey are to identify all significant sources of 60 Hz magnetic field in residences, estimate with sufficient accuracy the fraction of residences in which magnetic field exceeds any specified level, determine the relation between field and source parameters, and characterize spatial and temporal variations and harmonic content of the field. The data obtained relate to the level of the 60 Hz magnetic field and the source of the field, and not to personal exposure to magnetic fields, which is likely to be different due to the activity patterns of people. Magnetic fields from electrical appliances were measured intentionally away from the influence of appliance fields, which is limited to an area close to the appliance. Special measuring techniques were used to determine how the field varied within the living space of the house and over a twenty-four hour period. The field from each source is expressed in terms of how frequently a given field level is exceeded. The following sources of 60 Hz residential magnetic fields were identified: electrical appliances, grounding system of residences, overhead and underground power distribution lines, overhead power transmission lines, ground connections at electrical subpanels, and special wiring situations. Data from the appliance measurements is in a report published by EPRI, open-quotes Survey of Residential Magnetic Field Sources - Interim Reportclose quotes, TR-100194, which also provides much more detailed information on all subjects outlined in this paper

  4. An analysis of the impact of Renewable Portfolio Standards on residential electricity prices

    Science.gov (United States)

    Larson, Andrew James

    A Renewable Portfolio Standard (RPS) has become a popular policy for states seeking to increase the amount of renewable energy generated for consumers of electricity. The success of these state programs has prompted debate about the viability of a national RPS. The impact that these state level policies have had on the price consumers pay for electricity is the subject of some debate. Several federal organizations have conducted studies of the impact that a national RPS would have on electricity prices paid by consumers. NREL and US EIA utilize models that analyze the inputs in electricity generation to examine the future price impact of changes to electricity generation and show marginal increases in prices paid by end users. Other empirical research has produced similar results, showing that the existence of an RPS increases the price of electricity. These studies miss important aspects of RPS policies that may change how we view these price increases from RPS policies. By examining the previous empirical research on RPS policies, this study seeks to identify the controls necessary to build an effective model. These controls are utilized in a fixed effects model that seeks to show how the controls and variables of interest impact electricity prices paid by residential consumers of electricity. This study utilizes a panel data set from 1990 to 2014 to analyze the impact of these policies controlling for generating capacity, the regulatory status of utilities in each state, demographic characteristics of the states, and fuel prices. The results of the regressions indicate that prices are likely to be higher in states that have an RPS compared to states that do not have such a policy. Several of the characteristics mentioned above have price impacts, and so discussing RPS policies in the context of other factors that contribute to electricity prices is essential. In particular, the regulatory status of utilities in each state is an important determinate of price as

  5. Measure Guideline: Combustion Safety for Natural Draft Appliances Through Appliance Zone Isolation

    Energy Technology Data Exchange (ETDEWEB)

    Fitzgerald, J. [Center for Energy and Environment, Minneapolis, MN (United States); Bohac, D. [Center for Energy and Environment, Minneapolis, MN (United States)

    2014-04-01

    This measure guideline covers how to assess and carry out the isolation of natural draft combustion appliances from the conditioned space of low-rise residential buildings. It deals with combustion appliances located either within the living space in enclosed closets or side rooms or outside the living space in an adjacent area like an attic or garage. This subset of houses does not require comprehensive combustion safety tests and simplified prescriptive procedures can be used to address safety concerns. This allows residential energy retrofit contractors inexperienced in advanced combustion safety testing to effectively address combustion safety issues and allow energy retrofits including tightening and changes to distribution and ventilation systems to proceed.

  6. VersiCharge-SG - Smart Grid Capable Electric Vehicle Supply Equipment (EVSE) for Residential Applications

    Energy Technology Data Exchange (ETDEWEB)

    Wei, Dong [National Renewable Energy Lab. (NREL), Golden, CO (United States); Haas, Harry [National Renewable Energy Lab. (NREL), Golden, CO (United States); Terricciano, Paul [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-09-30

    In his 2011 State of the Union address, President Obama called for one million electric vehicles on the road by 2015 [1]. With large-scale Electric Vehicle (EV) or Plug-in Electric Vehicle (PEV or EV for short) or Plug-in Hybrid Electric Vehicle (PHEV) penetration into the US market, there will be drastic reduction in fossil fuel consumption, thus significantly reducing our dependency on foreign oil [2-6]. There will also be significant reduction on Green House Gas (GHG) emissions and smog in the major US cities [3, 7, 8]. Similar studies have also been done other industrial counties [9]. For the fuel cost, with the home electricity rate around $0.13 per kWh, it would cost about $0.05 per mile for DC operation and $0.03 cents per mile for AC operation. But, assuming 25 miles per gallon for a typical vehicle and $4 per gallon, fossil fuel will cost $0.16 per mile [10]. The overall lifecycle cost of PEVs will be several folds lower than the existing fossil fueled vehicles. Despite the above advantages of the EVs, the current cost of EVSE is not affordable for the average consumer. Presently, the cost of installing state-of-the-art residential EVSE ranges from $1500 to $2500 [11]. Low priced EVSE technology, which is easy to install, and affordable to operate and maintain by an average consumer, is essential for the large-scale market penetration of EVs. In addition, the long-term success of this technology is contingent on the PEVs having minimal excessive load and shift impact on the grid, especially at peak times. In a report [2] published by the Pacific Northwest National Laboratory (PNNL), the exiting electric power generation infrastructure, if used at its full capacity 24 hours a day, would support up to 84% of the nation’s cars, pickup trucks and SUVs for an average daily drive of 33 miles. This mileage estimate is certainly much below what an average driver would drive his/her vehicle per day. Another report [3] by the National Renewable Energy Laboratory

  7. Environmental determinants of unscheduled residential outages in the electrical power distribution of Phoenix, Arizona

    International Nuclear Information System (INIS)

    Maliszewski, Paul J.; Larson, Elisabeth K.; Perrings, Charles

    2012-01-01

    The sustainability of power infrastructures depends on their reliability. One test of the reliability of an infrastructure is its ability to function reliably in extreme environmental conditions. Effective planning for reliable electrical systems requires knowledge of unscheduled outage sources, including environmental and social factors. Despite many studies on the vulnerability of infrastructure systems, the effect of interacting environmental and infrastructural conditions on the reliability of urban residential power distribution remains an understudied problem. We model electric interruptions using outage data between the years of 2002 and 2005 across Phoenix, Arizona. Consistent with perceptions of increased exposure, overhead power lines positively correlate with unscheduled outages indicating underground cables are more resistant to failure. In the presence of overhead lines, the interaction between birds and vegetation as well as proximity to nearest desert areas and lakes are positive driving factors explaining much of the variation in unscheduled outages. Closeness to the nearest arterial road and the interaction between housing square footage and temperature are also significantly positive. A spatial error model was found to provide the best fit to the data. Resultant findings are useful for understanding and improving electrical infrastructure reliability. - Highlights: ► Unscheduled outages were related to interacting environmental and infrastructural conditions. ► Underground feeders are more resistant to failure. ► In the presence of overhead lines, birds, vegetation, and proximity to desert areas are positive driving factors. ► Proximity to arterial roads and a proxy for energy demand were significantly positive. ► Outages were most spatially dependent up to around 350 m.

  8. Homogeneous grouping of residential users of electric power in accordance with the variables that affect the consumption; Agrupamientos homogeneos de usuarios residenciales de energia electrica en funcion de las variables que impactan el consumo

    Energy Technology Data Exchange (ETDEWEB)

    Campero Littlewood, E.; Romero Cortes, J. [Departamento de Energia, Universidad Autonoma Metropolitana - Unidad Azcapotzalco, Mexico, D. F. (Mexico)

    1997-12-31

    This paper presents the results of the correlation analysis of the monthly consumption of electric power and the capacities in watts of the electric household appliances and domestic lighting performed in a sample of users of the residential tariff. To carry out this task, the information obtained in the answers to the inquiry applied to a group of dwellings, was used (the results of the inquiry are presented in another paper of this Seminar). The correlation variables were obtained from the nominal capacities or through the actual measurements of the energy consumption of the electric household appliances similar to the ones found in the visited homes. At the end of this paper the result of the application of the cluster analysis technic to obtain homogeneous groups of users, is presented, so as to be in position of estimating the shape of the hourly demand curve by means of the recording of the demand (watts) of a small sample of users. [Espanol] En este articulo se presenta el resultado de correlacion del consumo mensual de energia electrica y las capacidades en watts de los electrodomesticos e iluminacion realizado a una muestra de usuarios de tarifa residencial. Para este trabajo se utilizo la informacion obtenida en las respuestas de una encuesta aplicada en un conjunto habitacional (los resultados de la encuesta se presentan en otro articulo en este Seminario). Las variables de la correlacion se obtuvieron a partir de las especificaciones de capacidades o a traves de mediciones en electrodomesticos similares a los encontrados en los hogares. Al final se presenta el resultado de la aplicacion de la tecnica de formacion de agrupamientos `Cluster Analysis` para obtener grupos homogeneos de usuarios, de forma que se pueda estimar el perfil de demanda electrica mediante el registro de la demanda (watts) de una pequena muestra de usuarios.

  9. Homogeneous grouping of residential users of electric power in accordance with the variables that affect the consumption; Agrupamientos homogeneos de usuarios residenciales de energia electrica en funcion de las variables que impactan el consumo

    Energy Technology Data Exchange (ETDEWEB)

    Campero Littlewood, E; Romero Cortes, J [Departamento de Energia, Universidad Autonoma Metropolitana - Unidad Azcapotzalco, Mexico, D. F. (Mexico)

    1998-12-31

    This paper presents the results of the correlation analysis of the monthly consumption of electric power and the capacities in watts of the electric household appliances and domestic lighting performed in a sample of users of the residential tariff. To carry out this task, the information obtained in the answers to the inquiry applied to a group of dwellings, was used (the results of the inquiry are presented in another paper of this Seminar). The correlation variables were obtained from the nominal capacities or through the actual measurements of the energy consumption of the electric household appliances similar to the ones found in the visited homes. At the end of this paper the result of the application of the cluster analysis technic to obtain homogeneous groups of users, is presented, so as to be in position of estimating the shape of the hourly demand curve by means of the recording of the demand (watts) of a small sample of users. [Espanol] En este articulo se presenta el resultado de correlacion del consumo mensual de energia electrica y las capacidades en watts de los electrodomesticos e iluminacion realizado a una muestra de usuarios de tarifa residencial. Para este trabajo se utilizo la informacion obtenida en las respuestas de una encuesta aplicada en un conjunto habitacional (los resultados de la encuesta se presentan en otro articulo en este Seminario). Las variables de la correlacion se obtuvieron a partir de las especificaciones de capacidades o a traves de mediciones en electrodomesticos similares a los encontrados en los hogares. Al final se presenta el resultado de la aplicacion de la tecnica de formacion de agrupamientos `Cluster Analysis` para obtener grupos homogeneos de usuarios, de forma que se pueda estimar el perfil de demanda electrica mediante el registro de la demanda (watts) de una pequena muestra de usuarios.

  10. Technical and legal application possibilities of the compulsory labelling of the standby consumption of electrical household and office appliances - Project No. 53/03. Summary of the final report for the Federal Ministry of Economics and Labour

    Energy Technology Data Exchange (ETDEWEB)

    Schlomann, B.; Cremer, C.; Friedewald, M. [Fraunhofer-Institut fuer Systemtechnik und Innovationsforschung, Karlsruhe (DE)] (and others)

    2005-06-13

    The standby consumption of electrical households and office appliances continues to be significant world-wide since the number of products with standby components is constantly increasing. For Germany, a recent assessment of the Fraunhofer ISI (Cremer et al. 2003) for 2001 arrived at an electricity demand of almost 15 TWh for household and office appliances in standby mode. i.e. in standby and off-mode. This represents almost 40% of the total consumption of these appliances and around 3% of the total electricity demand of the final energy sectors in Germany. The standby share in electricity demand is over 80 or even 90% for numerous appliances. The Federal Environmental Agency calculated that every year standby losses in German households and offices are responsible for wasted electricity amounting to 3.5 billion Euro (UBA 2004). For the OECD countries, field studies show that between 3 and 13% of the electricity consumption of households can be ascribed to standby losses (IEA 2001). Without energy policy measures on both national and international levels, there is a great risk that a further increase in standby consumption will occur. Many studies dealing with this subject have already been conducted and have shown that low standby consumption is technically feasible and usually achievable at a reasonable cost. One possible energy policy measure to reduce the standby consumption of electrical household and office appliances is the introduction of mandatory consumption labelling. In principle, a high degree of effectiveness is attributed to such regulatory/command-and-control measures with regard to influencing the energy efficiency of devices. Compulsory energy labels to identify and, where necessary, to classify electricity consumption produce greater market transparency and offer buyers an additional decision criterion. In this way they promote indirectly the development, production and supply of energy-efficient products. When combined with comparatively low

  11. Scheduling home appliances for energy efficient buildings

    DEFF Research Database (Denmark)

    Rossello Busquet, Ana; Kardaras, Georgios; Iversen, Villy Bæk

    2010-01-01

    The number of appliances found in users’ homes is increasing together with electricity consumption of users’ residences. In addition, there is a tendency to consume during the same period leading to demand peaks. During these periods, electricity providers are forced to develop costly methods...... to generate enough power to meet consumers’ requirements. In addition, high demand peaks can lead to electricity shortages or even blackouts in certain areas. In order to avoid demand peaks, users’ appliances should consume electricity in a more distributed way. A new methodology to schedule the usage of home...... appliances is proposed and analyzed. The main concept behind this approach is the aggregation of home appliances into priority classes and the definition of a maximum power consumption threshold, which is not allowed to be exceeded during peak hours. The scenario simulated describes a modern household, where...

  12. An assessment of household electricity load curves and corresponding CO2 marginal abatement cost curves for Gujarat state, India

    International Nuclear Information System (INIS)

    Garg, Amit; Shukla, P.R.; Maheshwari, Jyoti; Upadhyay, Jigeesha

    2014-01-01

    Gujarat, a large industrialized state in India, consumed 67 TWh of electricity in 2009–10, besides experiencing a 4.5% demand–supply short-fall. Residential sector accounted for 15% of the total electricity consumption. We conducted load research survey across 21 cities and towns of the state to estimate residential electricity load curves, share of appliances by type and usage patterns for all types of household appliances at utility, geographic, appliance, income and end-use levels. The results indicate that a large scope exists for penetration of energy efficient devices in residential sector. Marginal Abatement Cost (MAC) curves for electricity and CO 2 were generated to analyze relative attractiveness of energy efficient appliance options. Results indicate that up to 7.9 TWh of electricity can be saved per year with 6.7 Mt-CO 2 emissions mitigation at negative or very low CO 2 prices of US$ 10/t-CO 2 . Despite such options existing, their penetration is not realized due to myriad barriers such as financial, institutional or awareness and therefore cannot be taken as baseline options for CO 2 emission mitigation regimes. - Highlights: • Residential sector provides focused mitigation opportunities. • Energy efficient space cooling is the main technology transition required. • Almost 26% residential load could be reduced by DSM measures. • Myriad barriers limit penetration of negative marginal cost efficient options

  13. Development of an Energy-Savings Calculation Methodology for Residential Miscellaneous Electric Loads: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Hendron, R.; Eastment, M.

    2006-08-01

    In order to meet whole-house energy savings targets beyond 50% in residential buildings, it will be essential that new technologies and systems approaches be developed to address miscellaneous electric loads (MELs). These MELs are comprised of the small and diverse collection of energy-consuming devices found in homes, including what are commonly known as plug loads (televisions, stereos, microwaves), along with all hard-wired loads that do not fit into other major end-use categories (doorbells, security systems, garage door openers). MELs present special challenges because their purchase and operation are largely under the control of the occupants. If no steps are taken to address MELs, they can constitute 40-50% of the remaining source energy use in homes that achieve 60-70% whole-house energy savings, and this percentage is likely to increase in the future as home electronics become even more sophisticated and their use becomes more widespread. Building America (BA), a U.S. Department of Energy research program that targets 50% energy savings by 2015 and 90% savings by 2025, has begun to identify and develop advanced solutions that can reduce MELs.

  14. Impact Analysis of Customized Feedback Interventions on Residential Electricity Load Consumption Behavior for Demand Response

    Directory of Open Access Journals (Sweden)

    Fei Wang

    2018-03-01

    Full Text Available Considering the limitations of traditional energy-saving policies, a kind of energy conservation method called the Information Feedback to Residential Electricity Load Customers, which could impact the demand response capacity, has increasingly received more attention. However, most of the current feedback programs provide the same feedback information to all customers regardless of their diverse characteristics, which may reduce the energy-saving effects or even backfire. This paper attempts to investigate how different types of customers may change their behaviors under a set of customized feedback. We conducted a field survey study in Qinhuangdao (QHD, China. First, we conducted semi-structured interviews to classify four groups of customers of different energy-saving awareness, energy-saving potential, and behavioral variability. Then, 156 QHD households were surveyed using scenarios to collect feedback of different scenarios. Social science theories were used to guide the discussion on the behavior changes as a result of different feedback strategies and reveal the reasons for customers’ behaviors. Using the Chi-Square test of independence, the variables that have strong correlations with the categories of residents are extracted to provide references for residents’ classification. Finally, the practical implications and needs for future research are discussed.

  15. Impact of roof integrated PV orientation on the residential electricity peak demand

    International Nuclear Information System (INIS)

    Sadineni, Suresh B.; Atallah, Fady; Boehm, Robert F.

    2012-01-01

    Highlights: ► A study to demonstrate peak load reductions at the substation. ► A new residential energy efficient community named Villa Trieste is being developed. ► The peak demand from the homes has decreased by 38% through energy efficiency. ► Orientation of roof integrated PV has less influence on the summer peak demand. ► Increasing thermostat temperature during peak by 1 °C can significantly reduce peaks. -- Abstract: Peak electricity demand has been an issue in the Desert Southwest region of the US, due to extreme summer temperatures. To address this issue, a consortium was formed between the University of Nevada, Las Vegas, Pulte Homes, and NV Energy. An energy efficient residential community was developed by the team in Las Vegas with approximately 200 homes to study substation-level peak reduction strategies. A summer peak reduction of more than 65%, between 1:00 PM and 7:00 PM, compared to code standard housing developments is the targeted goal of the project. Approximately 50 homes are already built and some are occupied. The energy performances of the homes have been monitored and are presented in this paper. Several peak electric load reduction strategies such as energy efficiency in buildings, roof integrated photovoltaics (PV) and direct load control have been applied. Though all the homes in the developed community are installed with 1.8 kW p PV systems, the orientation of the PV system depends on the building orientation. Focus of this paper is to find the impact of PV orientation on the peak load from a building. In addition, different time-of-use (TOU) energy pricing options are offered by the local electrical utility company. Hence it is important to find an optimal pricing option for each building. A computer model has been developed for one of the homes in the new development using building energy simulation code, ENERGY-10. Calculations on the PV orientations have shown that a south and 220° (i.e. 40° west of due south

  16. Potential Effect and Analysis of High Residential Solar Photovoltaic (PV Systems Penetration to an Electric Distribution Utility (DU

    Directory of Open Access Journals (Sweden)

    Jeffrey Tamba Dellosa

    2016-11-01

    Full Text Available The Renewable Energy Act of 2008 in the Philippines provided an impetus for residential owners to explore solar PV installations at their own rooftops through the Net-Metering policy. The Net-Metering implementation through the law however presented some concerns with inexperienced electric DU on the potential effect of high residential solar PV system installations. It was not known how a high degree of solar integration to the grid can possibly affect the operations of the electric DU in terms of energy load management. The primary objective of this study was to help the local electric DU in the analysis of the potential effect of high residential solar PV system penetration to the supply and demand load profile in an electric distribution utility (DU grid in the province of Agusan del Norte, Philippines. The energy consumption profiles in the year 2015 were obtained from the electric DU operating in the area. An average daily energy demand load profile was obtained from 0-hr to the 24th hour of the day based from the figures provided by the electric DU. The assessment part of the potential effect of high solar PV system integration assumed four potential total capacities from 10 Mega Watts (MW to 40 MW generated by all subscribers in the area under study at a 10 MW interval. The effect of these capacities were measured and analyzed with respect to the average daily load profile of the DU. Results of this study showed that a combined installations beyond 20 MWp coming from all subscribers is not viable for the local electric DU based on their current energy demand or load profile. Based from the results obtained, the electric DU can make better decisions in the management of high capacity penetration of solar PV systems in the future, including investment in storage systems when extra capacities are generated. Article History: Received July 15th 2016; Received in revised form Sept 23rd 2016; Accepted Oct 1st 2016; Available online How to Cite

  17. Achievement report for fiscal 1998 on development of advanced household electric appliance recycling technology; 1998 nendo senshinteki kaden recycle gijutsu kaihatsu seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    With an objective to develop a household electric appliance recycling technology, research and development has been made on crushing of compressors, separation of resins and metals, and regenerative utilization of urethane used as the refrigerator heat insulating material. In the compressor crushing technology, development was made on a ring hammer crusher of wood pattern horizontal type. In the research of the resin-metal separation technology, the dry-type separation and material purity were enhanced successfully by means of classification of materials to be crushed according to grain sizes, and classification using an eddy current screening device and a specific gravity screening device. In the research of the urethane regenerative utilization technology, the contained fluorocarbon was decomposed at the rate of 99.999% by modifying and rinsing the pyrolytic gas from the urethane by means of cracking, having achieved to make the material innocuous. The fuel gas thus obtained can be utilized for electric power generation. In addition, a method to granulate the material was established by mixing it with thermo-plastic resins. It was discovered that using the recovered urethane, which is pulverized smaller than 300 {mu} m, can elevate the heat insulation performance when it is used as the vacuum heat insulator, proving its capability of being re-utilized in refrigerators. (NEDO)

  18. FY 2000 report on the results of the development of the stand-by consumption power reduction technology. Verification experiment on the technology to reduce stand-by power of household electric appliances; 2000 nendo taikiji shohi denryoku sakugen gijutsu kaihatsu seika hokokusho. Kaden seihin taikiji denryoku sakugen gijutsu no jissho jikken

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Study was made of the energy conservation by reducing stand-by consumption power of household electric appliances. In the study, remote control, household electric appliance, and outlet box were developed, and a system was developed in which each of the three was connected by network and the commercial power source supply is cut off at the time of the stand-by state of household electric appliances. The outlet box collectively manages timer information and reservation information. User sends out control command toward the outlet box using the two-way remote control, and controls all the household electric appliances connected via network. The screen data of household electric appliances are sent to the two-way remote control via the outlet box and presented to user. When the time comes for automatic execution such as video recording during absence, the outlet box carries commercial power source to household electric appliances. Using these appliances, verification experiment was carried out in the model house which was built with the ordinary house as model. A reduction in stand-by consumption power, approximately 218kWh/year(center dot)household, was verified. (NEDO)

  19. Miscellaneous electricity use in U.S. homes

    International Nuclear Information System (INIS)

    Sanchez, Marla C.; Koomey, Jonathan G.; Moezzi, Mithra M.; Meier, Alan; Huber, Wolfgang

    1999-01-01

    Historically, residential energy and carbon saving efforts have targeted conventional end uses such as water heating, lighting and refrigeration. The emergence of new household appliances has transformed energy use from a few large and easily identifiable end uses into a broad array of ''miscellaneous'' energy services. This group of so called miscellaneous appliances has been a major contributor to growth in electricity demand in the past two decades. We use industry shipment data, lifetimes, and wattage and usage estimates of over 90 individual products to construct a bottom-up end use model (1976-2010). The model is then used to analyze historical and forecasted growth trends, and to identify the largest individual products within the miscellaneous end use. We also use the end use model to identify and analyze policy priorities. Our forecast projects that over the period 1996 to 2010, miscellaneous consumption will increase 115 TWh, accounting for over 90 percent of future residential electricity growth. A large portion of this growth will be due to halogen torchiere lamps and consumer electronics, making these two components of miscellaneous electricity a particularly fertile area for efficiency programs. Approximately 20 percent (40 TWh) of residential miscellaneous electricity is ''leaking electricity'' or energy consumed by appliances when they are not performing their principal function. If the standby power of all appliances with a standby mode is reduced to one watt, the potential energy savings equal 21 TWh/yr, saving roughly$1-2 billion annually

  20. Residential consumers in the Cape Peninsula's willingness to pay for premium priced green electricity

    Energy Technology Data Exchange (ETDEWEB)

    Oliver, Henry; Volschenk, Jako; Smit, Eon [University of Stellenbosch Business School, Carl Cronje Drive, Bellville, Western Cape 7535 (South Africa)

    2011-02-15

    A number of studies have explored the willingness (i.e. stated willingness as opposed to actual willingness) of consumers to pay a premium for green electricity in developed countries. However, little is known about how this translates into an emerging economy context. This study investigates the level of willingness of residential households in South Africa's Cape Peninsula to pay a premium for electricity from renewable energy. It methodologically drew on recent contributions in the literature on norm-motivated behaviour used to identify testable factors that could influence residential consumers' willingness to pay (WTP). Interestingly, the study found a significant positive link between household income and WTP for green electricity, contrary to the findings of some previous studies. Not only are higher income households more likely to pay a premium, but typically they are also willing to pay a bigger premium. It was also further established that the view that green electricity is reliable, involvement in the recycling of waste and the belief that everyone should contribute to green electricity generation drive the WTP. (author)

  1. Load Disaggregation via Pattern Recognition: A Feasibility Study of a Novel Method in Residential Building

    Directory of Open Access Journals (Sweden)

    Younghoon Kwak

    2018-04-01

    Full Text Available In response to the need to improve energy-saving processes in older buildings, especially residential ones, this paper describes the potential of a novel method of disaggregating loads in light of the load patterns of household appliances determined in residential buildings. Experiments were designed to be applicable to general residential buildings and four types of commonly used appliances were selected to verify the method. The method assumes that loads are disaggregated and measured by a single primary meter. Following the metering of household appliances and an analysis of the usage patterns of each type, values of electric current were entered into a Hidden Markov Model (HMM to formulate predictions. Thereafter, the HMM repeatedly performed to output the predicted data close to the measured data, while errors between predicted and the measured data were evaluated to determine whether they met tolerance. When the method was examined for 4 days, matching rates in accordance with the load disaggregation outcomes of the household appliances (i.e., laptop, refrigerator, TV, and microwave were 0.994, 0.992, 0.982, and 0.988, respectively. The proposed method can provide insights into how and where within such buildings energy is consumed. As a result, effective and systematic energy saving measures can be derived even in buildings in which monitoring sensors and measurement equipment are not installed.

  2. Change in consumer sensitivity to electricity prices in response to retail deregulation: A panel empirical analysis of the residential demand for electricity in the United States

    International Nuclear Information System (INIS)

    Nakajima, Tadahiro; Hamori, Shigeyuki

    2010-01-01

    About ten years have passed since the deregulation of the U.S. retail electricity market, and it is now generally accepted that the available data is adequate to quantitatively assess and compare conditions before and after deregulation. This study, therefore, estimates the changes in price elasticity in the residential electricity market to examine the changes, if any, in household sensitivity (as a result of retail electricity market deregulation policies) to residential electricity rates. Specifically, six types of panel data are prepared, based on three cross-sections-all states (except for Alaska and Hawaii) and the District of Columbia, deregulated states, and non-deregulated states-and two time series-the period before deregulation and the period after deregulation. The panel empirical analysis techniques are used to determine whether or not the variables are stationary, and to estimate price elasticity. We find that there is no substantial difference in the price elasticity between deregulated and non-deregulated states for both periods-before deregulation and after deregulation. Thus, it can be said that the deregulation of the retail electricity market has not made consumers more sensitive to electricity rates and that retail deregulation policies are not the cause of price elasticity differences between deregulated and non-deregulated states.

  3. Change in consumer sensitivity to electricity prices in response to retail deregulation. A panel empirical analysis of the residential demand for electricity in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Tadahiro [The Kansai Electric Power Company, Incorporated, 6-16, Nakanoshima 3-chome, Kita-Ku, Osaka 530-8270 (Japan); Hamori, Shigeyuki [Faculty of Economics, Kobe University 2-1, Rokkodai, Nada-Ku, Kobe 657-8501 (Japan)

    2010-05-15

    About ten years have passed since the deregulation of the U.S. retail electricity market, and it is now generally accepted that the available data is adequate to quantitatively assess and compare conditions before and after deregulation. This study, therefore, estimates the changes in price elasticity in the residential electricity market to examine the changes, if any, in household sensitivity (as a result of retail electricity market deregulation policies) to residential electricity rates. Specifically, six types of panel data are prepared, based on three cross-sections - all states (except for Alaska and Hawaii) and the District of Columbia, deregulated states, and non-deregulated states - and two time series - the period before deregulation and the period after deregulation. The panel empirical analysis techniques are used to determine whether or not the variables are stationary, and to estimate price elasticity. We find that there is no substantial difference in the price elasticity between deregulated and non-deregulated states for both periods - before deregulation and after deregulation. Thus, it can be said that the deregulation of the retail electricity market has not made consumers more sensitive to electricity rates and that retail deregulation policies are not the cause of price elasticity differences between deregulated and non-deregulated states. (author)

  4. Household consumption of different generations. Purchase of electric appliances and energy; Hushaallens konsumtion i olika generationer. Inkoep av eldriven hushaallsutrustning och energi

    Energy Technology Data Exchange (ETDEWEB)

    Carlsson-Kanyama, Annika; Stenerus, Ann-Sofie

    2008-02-15

    Considering that energy efficiency is an important task for the future, this study shows to what extent generation affiliation and other household characteristics affect consumption of primarily electrical household appliances and energy. The material used is a number of studies concerning household expenditures as well as average prices for goods and energy. Material from 1958, 1978, 1985, 1995 and 2003-2005 have been used. This report also includes a discussion regarding opportunities for energy efficiency. The term generation is explained in this context and earlier studies with relevance to generation affiliation and energy are summarized. An analysis of consumption habits among different generations highlights that the generations living in Sweden today experienced substantially different consumption opportunities during childhood and youth. Some generations have memories of much lower consumption levels, memories which could be recalled with the right policy instruments. The consumption experiences of the veteran generation are studied from 1958 up to 2003-2005, and this study also includes a comparison between the consumption levels in families with children in the 1950s and today. The current Swedish population have very different frames of reference concerning possible consumption styles. However, no generation would easily accept a more energy efficient lifestyle, because all generations have adapted to the increased consumption opportunities with high mobility and easy access. The analysis of household purchases of electrical appliances is based on information from 6 700 households (2003-2005) and 4 400 households (1985). The results are both surprising and expected. Generation affiliation is important for explaining expenditure levels for equipment for entertainment and information, where the youngest generations spend the most. But there are also differences related to gender as well as differences related to income and dwelling type. The differences

  5. Replacement or additional purchase: The impact of energy-efficient appliances on household electricity saving under public pressures

    International Nuclear Information System (INIS)

    Mizobuchi, Kenichi; Takeuchi, Kenji

    2016-01-01

    This study examined the influence of additional and replacement purchases of energy-efficient air-conditioners on power savings. We used a questionnaire survey and measured electricity use data from 339 Japanese households, collected from two city areas with different level of government-requested electricity-saving rates, namely, Osaka (10%) and Matsuyama (5%). The main findings of our study are as follows: (1) Households that purchased energy-efficient air-conditioners saved more electricity than those that did not. (2) “Additional-purchase households” showed significant energy savings, whereas “replacement households” did not. The rebound effect may negate the energy-saving effects of a new air-conditioner. (3) Altruistic attitude is associated with more active participation in power saving. (4) Households in Osaka saved more electricity than those in Matsuyama, probably because the government call to save electricity was more forceful. - Highlights: •Energy efficient air conditioner purchases affect household power savings. •Additional air conditioner purchase led to significant energy savings. •Replacement units did not produce more savings than non-purchase. • “Electricity conservation directives” amount had a significant power-saving effect. •Altruistic households were more likely to cooperate with power-saving requests.

  6. Switch green : Energy Star appliance feebate

    International Nuclear Information System (INIS)

    2007-01-01

    Between 1990 and 2004, greenhouse gas (GHG) emissions from the residential sector have grown by 10 per cent, and are likely to continue growing unless a policy aimed at reducing emissions is introduced. The residential sector is a significant contributor to Canada's overall GHG emissions, and an important source for potential reductions. This report presented the results of a study that described and evaluated a new economic instrument aimed at reducing greenhouse gas (GHG) emissions and energy consumption in Canada from household appliances, such as air conditioners, furnaces and boilers. Results of a quantitative analysis to determine the effect of changing taxation of residential appliances to reflect energy consumption and greenhouse gas emissions were presented. In addition, the report presented the results of a qualitative evaluation of the policy, using the criteria established in the 2005 budget plan, a framework for evaluating environmental tax proposals. The report outlined the context for the tax proposal that was evaluated and provided a summary of trends in Canada's greenhouse gas emissions and energy consumption as well as a discussion of important trends in residential energy consumption. A review of policies already in place to address energy consumption from household appliances was also presented. 11 tabs., 6 figs

  7. Refrigerator efficiency in Ghana: Tailoring an appliance market transformation program design for Africa

    International Nuclear Information System (INIS)

    Van Buskirk, Robert; Ben Hagan, Essel; Ofosu Ahenkorah, Alfred; McNeil, Michael A.

    2007-01-01

    In some cases, a simple replication of developed country appliance efficiency labels and standards may not be completely feasible in Ghana, Africa. Yet by creatively modifying the developed country appliance efficiency market transformation model, it should be possible to achieve dramatic energy use reductions. As was true in developed countries in the previous two decades, refrigeration efficiency improvements provide the greatest energy savings potential in the residential electricity sector in Ghana. Although Ghana, like many African countries may impose standards on imports since Ghana does not have manufacturing facilities for appliances in country. This approach may hurt some consumers who patronize a very diverse market of used appliances imported from Europe. We discuss how meeting the challenges of the Ghanaian market will require modification of the usual energy efficiency labeling and standards paradigm. But once a refrigerator market transformation is accomplished in Ghana, we estimate an average energy savings potential of 550 kWh/refrigerator/year, and a monetary savings of more than $35/refrigerator/year. We discuss how this modified refrigerator efficiency market transformation may occur in the Ghanaian context. If successful, this market transformation is likely to be an example for many other African countries

  8. Setting up charging electric stations within residential communities in current China: Gaming of government agencies and property management companies

    International Nuclear Information System (INIS)

    Wu, Tian; Ma, Lin; Mao, Zhonggen; Ou, Xunmin

    2015-01-01

    The difficulty of charging electric vehicles (EVs) is now hindering their further development. Governments generally choose to build stations for home charging (including piles) within residential communities. Given the conflict of interest between various government agencies and property management companies, constructing a charging station within residential communities would result in welfare loss for the property management companies and therefore lead to the principal–agent problem. This paper constructs a two-period imperfect information game theory model to study the moral hazard involved in this issue and government agencies' optimal choice. In the analytic solution of the model, we find that the optimal choice for a farsighted government agency is to constantly improve the incentive mechanism and introduce charging stations only when the conflict of interest is eliminated. Any benefits derived from government regulations by force would prove short-lived. The government should focus on long-term returns in the development of EVs, and its optimal mechanism should be designed to mitigate the principal–agent problem of property management companies, thereby accelerate the progress of EV charging infrastructure and improve overall social welfare. - Highlights: • The charging of electric vehicles (EVs) is hindering their use. • A game theory model is used for analysis of EV charging station construction. • Charging stations are in residential communities in China. • Government agencies are constantly improving incentive mechanisms

  9. Electric Industry Restructuring in Ohio: Residential and Low Income Customer Impacts; TOPICAL

    International Nuclear Information System (INIS)

    Eisenberg, J

    2001-01-01

    This report analyzes the electric utilities in Ohio in order to determine how they are situated for the coming of competition. It begins with the status of the utilities as of 1995, the last year for which detailed data were available, and determines the detailed underlying cost structure behind the rates charged to customers. The study then develops a number of restructuring scenarios to be analyzed. These scenarios cover different approaches to dividing stranded asset costs between customers and stockholders, and between different groups of customers. They also cover wholesale versus retail competition, different regulatory structures for those services still under regulation, and new approaches to stranded asset costs such as securitization--the use of special bonds to reduce costs. Throughout the report the special emphasis is on the impact of restructuring on low-income residential customers. Low-income customers are the most vulnerable to changes in the regulatory structure with the fewest alternative options. The report finds that there are a great deal of above-market cost, potentially stranded assets in Ohio--approximately$8.75 billion in 1995. The annual above-market costs total over$3 billion, of which about 2/3 is recovery of capital related costs and 1/3 is recovery of energy related costs. The distribution of stranded assets in Ohio is very uneven. Some utilities such as Cleveland Electric and Ohio Edison have very high levels of above-market costs. In contrast, Ohio Power has, under some estimates, costs which are actually below market costs. The study looks separately at the near-term or transition period (approximately the next seven to ten years) and the longer term competitive market period. During the transition period the costs of stranded assets are being collected from customers while competitive markets are being developed. In the longer term market period it is assumed that all of the stranded asset costs have been collected and that the

  10. The Effect of Electric Load Profiles on the Performance of Off-Grid Residential Hybrid Renewable Energy Systems

    Directory of Open Access Journals (Sweden)

    Stephen Treado

    2015-10-01

    Full Text Available This paper investigates the energy performance of off-grid residential hybrid renewable electric power systems, particularly the effect of electric load profiles on the ability to harvest available solar energy and avoid the consumption of auxiliary energy in the form of propane. The concepts are illustrated by an analysis of the energy performance of electric and propane-fired refrigerators. Off-grid electric power systems frequently incorporate a renewable source, such as wind or solar photovoltaic (PV, with a back-up power provided by a propane fueled motor/generator. Among other design decisions, residential consumers face the choice of employing an electric refrigerator with a conventional vapor compression refrigeration system, or a fuel-fired refrigerator operating as an absorption refrigeration system. One interesting question is whether it is more advantageous from an energy perspective to use electricity to run the refrigerator, which might be provided by some combination of the PV and propane motor/generator, thereby taking advantage of the relatively higher electric refrigerator Coefficient of Performance (COP and free solar energy but having to accept a low electrical conversion efficiency of the motor/generator, or use thermal energy from the combustion of propane to produce the refrigeration effect via an absorption system, albeit with a much lower COP. The analysis is complicated by the fact that most off-grid renewable electrical power systems utilize a battery bank to provide electrical power when it is not available from the wind turbine or PV system, so the state of charge of the battery bank will have a noticeable impact on what energy source is available at any moment in time. Daily electric load profiles combined with variable solar energy input determine the state of charge of the battery bank, with the degree of synchronization between the two being a critical factor in determining performance. The annual energy usage

  11. Home electrical system safety in Italy

    Energy Technology Data Exchange (ETDEWEB)

    Auditor,

    1990-06-01

    Italy, amongst the industrialized countries, has the highest mortality rate due to accidents associated with the improper use or maintenance of home electrical systems. The increasing use of domestic electrical appliances has raised the risk of accidents, especially in homes equipped with out-dated, low-capacity electrical plants and worn wiring. Within this context, this paper reports on the results of survey to establish the worthiness and type of electrical systems in use in a sample of 1,000 residential buildings. The paper then assesses the efficacy of recent normatives designed to increase the safety and efficiency of home electrical installations.

  12. Analyzing Residential End-Use Energy Consumption Data to Inform Residential Consumer Decisions and Enable Energy Efficiency Improvements

    Science.gov (United States)

    Carlson, Derrick R.

    While renewable energy is in the process of maturing, energy efficiency improvements may provide an opportunity to reduce energy consumption and consequent greenhouse gas emissions to bridge the gap between current emissions and the reductions necessary to prevent serious effects of climate change and will continue to be an integral part of greenhouse gas emissions policy moving forward. Residential energy is a largely untapped source of energy reductions as consumers, who wish to reduce energy consumption for monetary, environmental, and other reasons, face barriers. One such barrier is a lack of knowledge or understanding of how energy is consumed in a home and how to reduce this consumption effectively through behavioral and technological changes. One way to improve understanding of residential energy consumption is through the creation of a model to predict which appliances and electronics will be present and significantly contribute to the electricity consumption of a home on the basis of various characteristics of that home. The basis of this model is publically available survey data from the Residential Energy Consumption Survey (RECS). By predicting how households are likely to consume energy, homeowners, policy makers, and other stakeholders have access to valuable data that enables reductions in energy consumption in the residential sector. This model can be used to select homes that may be ripe for energy reductions and to predict the appliances that are the basis of these potential reductions. This work suggests that most homes in the U.S. have about eight appliances that are responsible for about 80% of the electricity consumption in that home. Characteristics such as census region, floor space, income, and total electricity consumption affect which appliances are likely to be in a home, however the number of appliances is generally around 8. Generally it takes around 4 appliances to reach the 50% threshold and 12 appliances to reach 90% of electricity

  13. Analysing socioeconomic diversity and scaling effects on residential electricity load profiles in the context of low carbon technology uptake

    International Nuclear Information System (INIS)

    McKenna, R.; Hofmann, L.; Merkel, E.; Fichtner, W.; Strachan, N.

    2016-01-01

    Adequately accounting for interactions between Low Carbon Technologies (LCTs) at the building level and the overarching energy system means capturing the granularity associated with decentralised heat and power supply in residential buildings. The approach presented here adds novelty in terms of a realistic socioeconomic differentiation by employing dwelling/household archetypes (DHAs) and neighbourhood clusters at the Output Area (OA) level. These archetypes are combined with a mixed integer linear program (MILP) to generate optimum (minimum cost) technology configurations and operation schedules. Even in the baseline case, without any LCT penetration, a substantial deviation from the standard load profile (SLP) is encountered, suggesting that for some neighbourhoods this profile is not appropriate. With the application of LCTs, including heat pumps, micro-CHP and photovoltaic (PV), this effect is much stronger, including more negative residual load, more variability, and higher ramps with increased LCT penetration, and crucially different between neighbourhood clusters. The main policy implication of the study is the importance of understanding electrical load profiles at the neighbourhood level, because of the consequences they have for investment in the overarching energy system, including transmission and distribution infrastructure, and centralised generation plant. Further work should focus on attaining a superior socioeconomic differentiation between households. - Highlights: • Low carbon technologies (LCTs) for heat/electricity in residential buildings. • Socioeconomic effects and interactions with overarching energy system. • Building thermal/electrical model combined with optimisation. • Significant differences between neighbourhood load profiles. • Policy implications: support for LCTs and investment in infrastructure.

  14. Comparison study of the technical characteristics and financial analysis of electric battery storage systems for residential grid

    Science.gov (United States)

    Palivos, Marios; Vokas, Georgios A.; Anastasiadis, Anestis; Papageorgas, Panagiotis; Salame, Chafic

    2018-05-01

    One of the major energy issues of our days is reliable and effective energy generation and supply of electricity grids. In recent years there has been experienced a rapid development and implementation of Renewable Energy Sources (RES) worldwide. On one hand, many Gigawatts of grid-connected renewables are being installed and on the other many Megawatts of hybrid renewable systems for residential use are being installed making use of electric battery systems, in order to cover all daily energy and power needs during. New types of batteries are being developed and many companies have made great progress providing a variety of electricity storage products. The purpose of this research is firstly to highlight the necessity and also the importance of the use of energy storage systems and secondly, through detailed technical and financial simulation analysis using HOMER Pro-optimization software, to compare the technical characteristics and performance of energy storage systems by various leading companies when installed in a residential renewable energy system with a specific load and at the same time to provide the most efficient system economically. Results concerning the operation and the choice of a storage system are derived.

  15. Incorporating experience curves in appliance standards analysis

    International Nuclear Information System (INIS)

    Desroches, Louis-Benoit; Garbesi, Karina; Kantner, Colleen; Van Buskirk, Robert; Yang, Hung-Chia

    2013-01-01

    There exists considerable evidence that manufacturing costs and consumer prices of residential appliances have decreased in real terms over the last several decades. This phenomenon is generally attributable to manufacturing efficiency gained with cumulative experience producing a certain good, and is modeled by an empirical experience curve. The technical analyses conducted in support of U.S. energy conservation standards for residential appliances and commercial equipment have, until recently, assumed that manufacturing costs and retail prices remain constant during the projected 30-year analysis period. This assumption does not reflect real market price dynamics. Using price data from the Bureau of Labor Statistics, we present U.S. experience curves for room air conditioners, clothes dryers, central air conditioners, furnaces, and refrigerators and freezers. These experience curves were incorporated into recent energy conservation standards analyses for these products. Including experience curves increases the national consumer net present value of potential standard levels. In some cases a potential standard level exhibits a net benefit when considering experience, whereas without experience it exhibits a net cost. These results highlight the importance of modeling more representative market prices. - Highlights: ► Past appliance standards analyses have assumed constant equipment prices. ► There is considerable evidence of consistent real price declines. ► We incorporate experience curves for several large appliances into the analysis. ► The revised analyses demonstrate larger net present values of potential standards. ► The results imply that past standards analyses may have undervalued benefits.

  16. Mitigation of the Impact of High Plug-in Electric Vehicle Penetration on Residential Distribution Grid Using Smart Charging Strategies

    Directory of Open Access Journals (Sweden)

    Chong Cao

    2016-12-01

    Full Text Available Vehicle electrification presents a great opportunity to reduce transportation greenhouse gas emissions. The greater use of plug-in electric vehicles (PEVs, however, puts stress on local distribution networks. This paper presents an optimal PEV charging control method integrated with utility demand response (DR signals to mitigate the impact of PEV charging to several aspects of a grid, including load surge, distribution accumulative voltage deviation, and transformer aging. To build a realistic PEV charging load model, the results of National Household Travel Survey (NHTS have been analyzed and a stochastic PEV charging model has been defined based on survey results. The residential distribution grid contains 120 houses and is modeled in GridLAB-D. Co-simulation is performed using Matlab and GridLAB-D to enable the optimal control algorithm in Matlab to control PEV charging loads in the residential grid modeled in GridLAB-D. Simulation results demonstrate the effectiveness of the proposed optimal charging control method in mitigating the negative impacts of PEV charging on the residential grid.

  17. Prediction of greenhouse gas reduction potential in Japanese residential sector by residential energy end-use model

    International Nuclear Information System (INIS)

    Shimoda, Yoshiyuki; Yamaguchi, Yukio; Okamura, Tomo; Taniguchi, Ayako; Yamaguchi, Yohei

    2010-01-01

    A model is developed that simulates nationwide energy consumption of the residential sector by considering the diversity of household and building types. Since this model can simulate the energy consumption for each household and building category by dynamic energy use based on the schedule of the occupants' activities and a heating and cooling load calculation model, various kinds of energy-saving policies can be evaluated with considerable accuracy. In addition, the average energy efficiency of major electric appliances used in the residential sector and the percentages of housing insulation levels of existing houses is predicted by the 'stock transition model.' In this paper, energy consumption and CO 2 emissions in the Japanese residential sector until 2025 are predicted. For example, as a business - as-usual (BAU) case, CO 2 emissions will be reduced by 7% from the 1990 level. Also evaluated are mitigation measures such as the energy efficiency standard for home electric appliances, thermal insulation code, reduction of standby power, high-efficiency water heaters, energy-efficient behavior of occupants, and dissemination of photovoltaic panels.

  18. PAT portable appliance testing

    CERN Document Server

    2011-01-01

    The Electricity at Work Regulations 1989 require any electrical system to be constructed, maintained and used in such a manner as to prevent danger. This means that inspection and testing of systems, including portable appliances, is needed in order to determine if maintenance is required.This book explains in clear language what needs to be done and includes expert advice on legislation as well as actual testing. The book contains an appendix providing the electrical fundamentals needed by non-specialists and also has sample questions (with answers) for the C&G 2377 exam that anyone who conducts this work is required to take by law.It is an affordable and handy reference for electricians who administer PAT. It is also an ideal refesher and revision guide for the non-specialist, such as maintenance staff, caretakers and charity shop volunteers who carry out these tasks part-time, alongside their many other duties.Brian Scaddan, I Eng, MIET, is a consultant for and an Honorary Member of City & Guilds. ...

  19. Scheduling Appliances with GA, TLBO, FA, OSR and Their Hybrids Using Chance Constrained Optimization for Smart Homes

    Directory of Open Access Journals (Sweden)

    Zunaira Nadeem

    2018-04-01

    Full Text Available In this paper, we design a controller for home energy management based on following meta-heuristic algorithms: teaching learning-based optimization (TLBO, genetic algorithm (GA, firefly algorithm (FA and optimal stopping rule (OSR theory. The principal goal of designing this controller is to reduce the energy consumption of residential sectors while reducing consumer’s electricity bill and maximizing user comfort. Additionally, we propose three hybrid schemes OSR-GA, OSR-TLBO and OSR-FA, by combining the best features of existing algorithms. We have also optimized the desired parameters: peak to average ratio, energy consumption, cost, and user comfort (appliance waiting time for 20, 50, 100 and 200 heterogeneous homes in two steps. In the first step, we obtain the optimal scheduling of home appliances implementing our aforementioned hybrid schemes for single and multiple homes while considering user preferences and threshold base policy. In the second step, we formulate our problem through chance constrained optimization. Simulation results show that proposed hybrid scheduling schemes outperformed for single and multiple homes and they shift the consumer load demand exceeding a predefined threshold to the hours where the electricity price is low thus following the threshold base policy. This helps to reduce electricity cost while considering the comfort of a user by minimizing delay and peak to average ratio. In addition, chance-constrained optimization is used to ensure the scheduling of appliances while considering the uncertainties of a load hence smoothing the load curtailment. The major focus is to keep the appliances power consumption within the power constraint, while keeping power consumption below a pre-defined acceptable level. Moreover, the feasible regions of appliances electricity consumption are calculated which show the relationship between cost and energy consumption and cost and waiting time.

  20. Dynamic management of integrated residential energy systems

    Science.gov (United States)

    Muratori, Matteo

    dissertation presents a bottom-up highly resolved model of a generic residential energy eco-system in the United States. The model is able to capture the entire energy footprint of an individual household, to include all appliances, space conditioning systems, in-home charging of plug-in electric vehicles, and any other energy needs, viewing residential and transportation energy needs as an integrated continuum. The residential energy eco-system model is based on a novel bottom-up approach that quantifies consumer energy use behavior. The incorporation of stochastic consumer behaviors allows capturing the electricity consumption of each residential specific end-use, providing an accurate estimation of the actual amount of available controllable resources, and for a better understanding of the potential of residential demand response programs. A dynamic energy management framework is then proposed to manage electricity consumption inside each residential energy eco-system. Objective of the dynamic energy management framework is to optimize the scheduling of all the controllable appliances and in-home charging of plug-in electric vehicles to minimize cost. Such an automated energy management framework is used to simulate residential demand response programs, and evaluate their impact on the electric power infrastructure. For instance, time-varying electricity pricing might lead to synchronization of the individual residential demands, creating pronounced rebound peaks in the aggregate demand that are higher and steeper than the original demand peaks that the time-varying electricity pricing structure intended to eliminate. The modeling tools developed in this study can serve as a virtual laboratory for investigating fundamental economic and policy-related questions regarding the interplay of individual consumers with energy use. The models developed allow for evaluating the impact of different energy policies, technology adoption, and electricity price structures on the total

  1. Research & Development Roadmap for Next-Generation Appliances

    Energy Technology Data Exchange (ETDEWEB)

    Goetzler, William [Navigant Consulting, Inc., Burlington, MA (United States); Sutherland, Timothy [Navigant Consulting, Inc., Burlington, MA (United States); Foley, Kevin [Navigant Consulting, Inc., Burlington, MA (United States)

    2012-03-01

    Appliances present an attractive opportunity for near-term energy savings in existing building, because they are less expensive and replaced more regularly than heating, ventilation, and air-conditioning (HVAC) systems or building envelope components. This roadmap targets high-priority research and development (R&D), demonstration and commercialization activities that could significantly reduce residential appliance energy consumption. The main objective of the roadmap is to seek activities that accelerate the commercialization of high-efficiency appliance technologies while maintaining the competitiveness of American industry. The roadmap identified and evaluated potential technical innovations, defined research needs, created preliminary research and development roadmaps, and obtained stakeholder feedback on the proposed initiatives.

  2. Techno-economic feasibility of hybrid diesel/PV/wind/battery electricity generation systems for non-residential large electricity consumers under southern Iran climate conditions

    International Nuclear Information System (INIS)

    Baneshi, Mehdi; Hadianfard, Farhad

    2016-01-01

    Highlights: • A hybrid electricity generation system for a large electricity consumer was studied. • The PV and wind electricity potentials under given climate conditions were evaluated. • Technical, economical, and environmental issues of different systems were discussed. • The optimum configuration of components was obtained. • The impacts of governmental incentives on economic viability of systems were examined. - Abstract: This paper aims to study the techno-economical parameters of a hybrid diesel/PV/wind/battery power generation system for a non-residential large electricity consumer in the south of Iran. As a case study, the feasibility of running a hybrid system to meet a non-residential community’s load demand of 9911 kWh daily average and 725 kW peak load demand was investigated. HOMER Pro software was used to model the operation of the system and to identify the appropriate configuration of it based on comparative technical, economical, and environmental analysis. Both stand alone and grid connected systems were modeled. The impacts of annual load growth and governmental energy policies such as providing low interest loan to renewable energy projects, carbon tax, and modifying the grid electricity price on viability of the system were discussed. Results show that for off-grid systems the cost of electricity (COE) and the renewable fraction of 9.3–12.6 ₵/kWh and 0–43.9%, respectively, are achieved with photovoltaic (PV) panel, wind turbine, and battery sizes of 0–1000 kW, 0–600 kW, and 1300 kWh, respectively. For on grid systems without battery storage the range of COE and renewable fraction are 5.7–8.4 ₵/kWh and 0–53%, respectively, for the same sizes of PV panel and wind turbine.

  3. Initial transformer sizing for single-phase residential load

    International Nuclear Information System (INIS)

    Schneider, K.C.; Hoad, R.F.

    1992-01-01

    The purchase of distribution transformers represents a significant capital investment per year for an electric utility. Choosing the correct thermal and economic size transformer can help control this investment. This paper describes a method for determining the correct economic size of distribution transformers using end-use appliance load profiles and the ANSI/IEEE Standard C57.91-1981 thermal model. Although applied only to single family and multifamily residential load in this paper, the method can be extended to other types of load such as commercial or industrial

  4. Renewable energy rebound effect?: Estimating the impact of state renewable energy financial incentives on residential electricity consumption

    Science.gov (United States)

    Stephenson, Beth A.

    Climate change is a well-documented phenomenon. If left unchecked greenhouse gas emissions will continue global surface warming, likely leading to severe and irreversible impacts. Generating renewable energy has become an increasingly salient topic in energy policy as it may mitigate the impact of climate change. State renewable energy financial incentives have been in place since the mid-1970s in some states and over 40 states have adopted one or more incentives at some point since then. Using multivariate linear and fixed effects regression for the years 2002 through 2012, I estimate the relationship between state renewable energy financial incentives and residential electricity consumption, along with the associated policy implications. My hypothesis is that a renewable energy rebound effect is present; therefore, states with renewable energy financial incentives have a higher rate of residential electricity consumption. I find a renewable energy rebound effect is present in varying degrees for each model, but the results do not definitively indicate how particular incentives influence consumer behavior. States should use caution when adopting and keeping renewable energy financial incentives as this may increase consumption in the short-term. The long-term impact is unclear, making it worthwhile for policymakers to continue studying the potential for renewable energy financial incentives to alter consumer behavior.

  5. The flexibility of household electricity demand over time

    International Nuclear Information System (INIS)

    Halvorsen, B.; Larsen, B.M.

    2001-01-01

    Empirical estimates of long run effects on residential electricity demand from changes in the electricity price are usually estimated by cross-sectional variation in the current stock of electric household appliances across households at a certain point in time. Here, we use a discrete-continuous approach modeling the long run effects by investments in new appliances. We apply the annual Norwegian Survey of Consumer Expenditure for the period 1975 to 1994 to estimate the short and long run own price elasticities in the two approaches. We find the estimated long run elasticity only slightly more price elastic than the short run. We also find that the long run elasticity does not differ significantly between the two approaches. The reason for both results is that, since there is no alternative source of energy for these appliances, there are no substitution effects

  6. Preliminary Study of Perception and Consumer Behaviour Towards Energy Saving for Household Appliances: A Case of Makassar

    Science.gov (United States)

    Syam Akil, Yusri; Mangngenre, Saiful; Mawar, Sri; Amar, Kifayah

    2018-03-01

    Electricity load has tendency to increase over the time. Therefore, efforts to maintain a balance between electricity supply and demand such as increasing energy saving related to the use of home electricity appliances are urgently needed. In general, one of the household appliances which consumes relatively high electricity energy is refrigerator. The purpose of this study is to analyze residential consumers perceptions and their behaviours about electricity energy saving in relation to the usage of household appliances in Makassar, Indonesia particularly for refrigerator. Moreover, typical relationship between perceptions and consumers behaviours is also analyzed by composed two regression models, namely model for usage behaviour (UREFm model) and model for habitual behaviour (HREFm model) by using general perception, specific perception, and external factors as explanation variables. To collect data, a questionnaire was designed for survey which involved 40 respondents as a preliminary study and then statistical tests including regression analysis were applied to analyze usable data. The target of respondent was an owner of a house in Makassar with installed power capacity at least 900 VA. Reliability test shown that all items in the developed questionnaire can be used for main survey as obtained Cronbach’s alpha values were above 0.6. Evaluation for consumers perceptions on energy saving in relation to demographic aspect using mean and Standard Deviation values indicated some significant differences. Other results regarding regression analysis shown that both composed models were well validated and had quite good fitness degree with adjusted R-squared values around 49.31% for UREFm model and 80.90% for HREFm model. Among considered variables, specific perception, and external factors were found have significant influence to the usage and habitual behaviours of consumers as confirmed by their p-values in each model below 0.05. Findings of this research can be

  7. Introducing a demand-based electricity distribution tariff in the residential sector: Demand response and customer perception

    International Nuclear Information System (INIS)

    Bartusch, Cajsa; Wallin, Fredrik; Odlare, Monica; Vassileva, Iana; Wester, Lars

    2011-01-01

    Increased demand response is essential to fully exploit the Swedish power system, which in turn is an absolute prerequisite for meeting political goals related to energy efficiency and climate change. Demand response programs are, nonetheless, still exceptional in the residential sector of the Swedish electricity market, one contributory factor being lack of knowledge about the extent of the potential gains. In light of these circumstances, this empirical study set out with the intention of estimating the scope of households' response to, and assessing customers' perception of, a demand-based time-of-use electricity distribution tariff. The results show that households as a whole have a fairly high opinion of the demand-based tariff and act on its intrinsic price signals by decreasing peak demand in peak periods and shifting electricity use from peak to off-peak periods. - Highlights: → Households are sympathetic to demand-based tariffs, seeing as they relate to environmental issues. → Households adjust their electricity use to the price signals of demand-based tariffs. → Demand-based tariffs lead to a shift in electricity use from peak to off-peak hours. → Demand-based tariffs lead to a decrease in maximum demand in peak periods. → Magnitude of these effects increases over time.

  8. Appliance based control for Home Power Management Systems

    International Nuclear Information System (INIS)

    Özkan, Hanife Apaydın

    2016-01-01

    This study scrutinizes energy-friendly smart home appliances (hereafter ‘smart appliances’), control of these appliances and their effects on the efficient use of energy. To accomplish this, smart appliances and their operation principles are introduced and their energy savings compared to conventional appliances are analyzed using precise measurements. Then, a real-time Appliance-based Home Power Management System (Ab-HPMS) which manages power consumption of smart appliances and that of the house as a whole is proposed. For Ab-HPMS, an appliance control algorithm, called Appliance-based Rolling Wave Planning (Ab-RWP), is developed with the aim of reducing electricity cost and improving energy efficiency while maintaining user comfort. Ab-RWP algorithm interacts with appliances in a priority order based on user comfort which is determined by utilizing their smart operational characteristics. Operations of smart appliances and their integrations with Ab-HPMS are modeled with Petri nets to verify that they meet the requirements expressed in the specifications. Simulation results demonstrate that proposed Ab-HPMS provides improvements in terms of the energy consumption reduction of about 5%–16%, cost reduction of about 10%–24% and peak reduction at high demand period of about 38%–53% compared to conventional appliances usage. - Highlights: • The effects of smart home appliances on energy saving are investigated. • Petri nets models of smart appliances are developed to simulate their operations in smart home. • A real-time appliance-based home power management system (Ab-HPMS) is proposed. • Power density function is evaluated to interrupt the operation of smart washing machine.

  9. Created in Close Interaction with the Industry: The Smart Appliances REFerence (SAREF) Ontology

    NARCIS (Netherlands)

    Daniele, L.M.; Hartog, F.T.H. den; Roes, J.B.M.

    2015-01-01

    Around two thirds of the energy consumed by buildings can be traced back to the residential sectors and thus household appliances. Today, most appliances are highly intelligent and networked devices, in principle being able to form complete energy consuming, producing, and managing systems. Reducing

  10. The greenhouse advantage of natural gas appliances

    International Nuclear Information System (INIS)

    Coombe, N.

    2000-01-01

    The life cycle report prepared recently by Energetics for the AGA, Assessment of Greenhouse Gas Emissions from Natural Gas, demonstrates clearly the greenhouse advantage natural gas has over coal in generating electricity. This study also goes one step further in applying this life cycle approach to the use of space and water heating within the home. The study shows the significant green-house advantage that natural gas appliances have over electric appliances. Findings from other studies also support this claim. The natural gas suppliers are encouraged to take advantage of the marketing opportunity that these studies provide, offering the householders the fuel that will significantly reduce their contribution to greenhouse emission

  11. Customer-economics of residential photovoltaic systems (Part 1): The impact of high renewable energy penetrations on electricity bill savings with net metering

    International Nuclear Information System (INIS)

    Darghouth, Naïm R.; Barbose, Galen; Wiser, Ryan H.

    2014-01-01

    Residential photovoltaic (PV) systems in the US are often compensated at the customer's underlying retail electricity rate through net metering. Given the uncertainty in future retail rates and the inherent links between rates and the customer–economics of behind-the-meter PV, there is growing interest in understanding how potential changes in rates may impact the value of bill savings from PV. In this article, we first use a production cost and capacity expansion model to project California hourly wholesale electricity market prices under two potential electricity market scenarios, including a reference and a 33% renewables scenario. Second, based on the wholesale electricity market prices generated by the model, we develop retail rates (i.e., flat, time-of-use, and real-time pricing) for each future scenario based on standard retail rate design principles. Finally, based on these retail rates, the bill savings from PV is estimated for 226 California residential customers under two types of net metering, for each scenario. We find that high renewable penetrations can drive substantial changes in residential retail rates and that these changes, together with variations in retail rate structures and PV compensation mechanisms, interact to place substantial uncertainty on the future value of bill savings from residential PV. - Highlights: • We investigate the impact of high renewables on customer economics of solar. • We model three types of residential retail electricity rates. • Based on the rates, we calculate the bill savings from photovoltaic (PV) generation. • High renewables penetration can lead to lower bill savings with time-varying rates. • There is substantial uncertainty in the future bill savings from residential PV

  12. Energy saving or privatization? The case of the electric residential sector of Mexico; Ahorro de energia o privatizacion? El caso del sector electrico residencial de Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Friedmann, Rafael [University of California, Berkeley, CA (United States)

    1994-12-31

    The validity of the premise that proposes the privatization of the electric sector as a solution to the problem of obtaining enough investment capital for the continuous expansion of the electric sector is examined. It is shown that the growth of the demand foreseen for the residential sector for year 2000, can be totally reduced by introducing technologies economically feasible to increase the efficiency and end uses of the residential electricity. With the efficient use of the electricity, the economical development is allowed for the residential sector, without large increments of the residential electricity demand. [Espanol] Se examina la validez de la premisa que propone la privatizacion del sector electrico como una solucion al problema de conseguir suficientes capitales de inversion para la continua expansion del sector. Se muestra que se puede reducir casi totalmente el crecimiento en la demanda prevista del sector residencial al ano 2000, introduciendo tecnologias economicamente factibles para aumentar la eficiencia en los usos finales de electricidad residencial. Con el uso eficiente de la electricidad, se permite el desarrollo economico del sector residencial sin grandes incrementos en la demanda residencial de electricidad.

  13. Energy saving or privatization? The case of the electric residential sector of Mexico; Ahorro de energia o privatizacion? El caso del sector electrico residencial de Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Friedmann, Rafael [University of California, Berkeley, CA (United States)

    1993-12-31

    The validity of the premise that proposes the privatization of the electric sector as a solution to the problem of obtaining enough investment capital for the continuous expansion of the electric sector is examined. It is shown that the growth of the demand foreseen for the residential sector for year 2000, can be totally reduced by introducing technologies economically feasible to increase the efficiency and end uses of the residential electricity. With the efficient use of the electricity, the economical development is allowed for the residential sector, without large increments of the residential electricity demand. [Espanol] Se examina la validez de la premisa que propone la privatizacion del sector electrico como una solucion al problema de conseguir suficientes capitales de inversion para la continua expansion del sector. Se muestra que se puede reducir casi totalmente el crecimiento en la demanda prevista del sector residencial al ano 2000, introduciendo tecnologias economicamente factibles para aumentar la eficiencia en los usos finales de electricidad residencial. Con el uso eficiente de la electricidad, se permite el desarrollo economico del sector residencial sin grandes incrementos en la demanda residencial de electricidad.

  14. What's driving energy efficient appliance label awareness and purchase propensity?

    International Nuclear Information System (INIS)

    Mills, Bradford; Schleich, Joachim

    2010-01-01

    The EU appliance energy consumption labeling scheme is a key component of efforts to increase the diffusion of energy-efficient household appliances. In this paper, the determinants of consumer knowledge of the energy label for household appliances and the choice of class-A energy-efficient appliances are jointly estimated using data from a large survey of more than 20,000 German households. The results for five major appliances suggest that lack of knowledge of the energy label can generate considerable bias in both estimates of rates of uptake of class-A appliances and in estimates of the underlying determinants of choice of class-A appliance. Simulations of the choice to purchase a class-A appliance, given knowledge of the labeling framework, reveal that residence characteristics and, in several cases, regional electricity prices strongly increase the propensity to purchase a class-A appliance, but socio-economic characteristics have surprisingly little impact on appliance energy-class choice.

  15. Development of a High-Fidelity Model for an Electrically Driven Energy Storage Flywheel Suitable for Small Scale Residential Applications

    Directory of Open Access Journals (Sweden)

    Mustafa E. Amiryar

    2018-03-01

    Full Text Available Energy storage systems (ESS are key elements that can be used to improve electrical system efficiency by contributing to balance of supply and demand. They provide a means for enhancing the power quality and stability of electrical systems. They can enhance electrical system flexibility by mitigating supply intermittency, which has recently become problematic, due to the increased penetration of renewable generation. Flywheel energy storage systems (FESS are a technology in which there is gathering interest due to a number of advantages offered over other storage solutions. These technical qualities attributed to flywheels include high power density, low environmental impact, long operational life, high round-trip efficiency and high cycle life. Furthermore, when configured in banks, they can store MJ levels of energy without any upper limit. Flywheels configured for grid connected operation are systems comprising of a mechanical part, the flywheel rotor, bearings and casings, and the electric drive part, inclusive of motor-generator (MG and power electronics. This contribution focusses on the modelling and simulation of a high inertia FESS for energy storage applications which has the potential for use in the residential sector in more challenging situations, a subject area in which there are few publications. The type of electrical machine employed is a permanent magnet synchronous motor (PMSM and this, along with the power electronics drive, is simulated in the MATLAB/Simulink environment. A brief description of the flywheel structure and applications are given as a means of providing context for the electrical modelling and simulation reported. The simulated results show that the system run-down losses are 5% per hour, with overall roundtrip efficiency of 88%. The flywheel speed and energy storage pattern comply with the torque variations, whilst the DC-bus voltage remains constant and stable within ±3% of the rated voltage, regardless of

  16. Electric power of residential photovoltaic power system; Jutakuyo taiyoko hatsuden system no hatsudenryo

    Energy Technology Data Exchange (ETDEWEB)

    Asano, K.; Kawamura, H.; Yamanaka, S.; Kawamura, H.; Ono, H.; Hayashi, K.; Naganawa, H. [Meijo University, Nagoya (Japan); Asai, H.

    1996-10-27

    Measurement was done on the annual power generation of a residential photovoltaic power system that was most suitable for the present situation in utilizing solar energy; and an examination was made on the basis of the data of a module in which an optimal operation load control was separately installed in order to operate the system more effectively. As a result, it was found that the introduction of a 3kW class system was currently most desirable as a residential photovoltaic power system, and that the problem of the optimal operation load control was crucial for the more efficient power generation. The resistance value of the optimal operation load was stable between 6 and 8 ohm in the daytime in fine weather. However, it was observed that, where no sufficient insolation was expected, the optimal operation load was ten times as much as in fine weather, being easily influenced by the environmental elements. In addition, it was revealed that, if the operation load was fixed at a specific value (6 ohm) in a clear day, the power generation was only about 85% compared with the case of controlling the optimal operation load. This figure was obtained under comparatively favorable conditions, however. 8 refs., 7 figs.

  17. Advisory report on licence requirements for the marketing of natural gas and electricity to residential and small commercial consumers

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-10-06

    The proposed Ontario Energy Board Act, 1998 which forms part of Bill 35, would make it possible for the Board to make regulations prescribing license requirements and conditions for sellers of natural gas and electricity to residential and small commercial users. Interested stakeholders were invited to provide their input on the proposed Act. A total of 23 parties responded by submitting their comments to the Ontario Energy Board. This document presents the concerns of several parties regarding various provisions of the proposed regulatory regime affecting energy marketing. Comments on the definition of `low volume customer`, on classes of gas marketers, need and requirements for gas marketer`s licence, the form and posting of security bonds by prospective gas marketers, exemptions from licensing, conditions of licensing, code of conduct for energy marketers, disclosure of customer information, were some of the proposed provisions that elicited comments.

  18. Advisory report on licence requirements for the marketing of natural gas and electricity to residential and small commercial consumers

    International Nuclear Information System (INIS)

    1998-01-01

    The proposed Ontario Energy Board Act, 1998 which forms part of Bill 35, would make it possible for the Board to make regulations prescribing license requirements and conditions for sellers of natural gas and electricity to residential and small commercial users. Interested stakeholders were invited to provide their input on the proposed Act. A total of 23 parties responded by submitting their comments to the Ontario Energy Board. This document presents the concerns of several parties regarding various provisions of the proposed regulatory regime affecting energy marketing. Comments on the definition of 'low volume customer', on classes of gas marketers, need and requirements for gas marketer's licence, the form and posting of security bonds by prospective gas marketers, exemptions from licensing, conditions of licensing, code of conduct for energy marketers, disclosure of customer information, were some of the proposed provisions that elicited comments

  19. Economics of appliance efficiency

    International Nuclear Information System (INIS)

    Tiedemann, K.H.

    2009-01-01

    Several significant developments occurred in 2001 that affect the impact of market transformation programs. This paper presented and applied an econometric approach to the identification and estimation of market models for refrigerators, clothes washers, dishwashers and room air conditioners. The purpose of the paper was to understand the impact of energy conservation policy developments on sales of energy efficient appliances. The paper discussed the approach with particular reference to building a database of sales and drivers of sales using publicly available information; estimation of the determinants of sales using econometric models; and estimation of the individual impacts of prices, gross domestic product (GDP) and energy conservation policies on sales using regression results. Market and policy developments were also presented, such as change a light, save the world promotion; the California energy crisis; and the Pacific Northwest drought induced hydro power shortage. It was concluded that an increase in GDP increased the sales of both more efficient and less efficient refrigerators, clothes washers, dishwashers, and room air conditioners. An increase in electricity price increased sales of Energy Star refrigerators, clothes washers, dishwashers, and room air conditioners. 4 refs., 8 tabs.

  20. Particulate and gaseous emissions from residential biomass combustion

    International Nuclear Information System (INIS)

    Boman, Christoffer

    2005-04-01

    Biomass is considered to be a sustainable energy source with significant potentials for replacing electricity and fossil fuels, not at least in the residential sector. However, present wood combustion is a major source of ambient concentrations of hydrocarbons (e.g. VOC and PAH) and particulate matter (PM) and exposure to these pollutants have been associated with adverse health effects. Increased focus on combustion related particulate emissions has been seen concerning the formation, characteristics and implications to human health. Upgraded biomass fuels (e.g. pellets) provide possibilities of more controlled and optimized combustion with less emission of products of incomplete combustion (PICs). For air quality and health impact assessments, regulatory standards and evaluations concerning residential biomass combustion, there is still a need for detailed emission characterization and quantification when using different fuels and combustion techniques. This thesis summarizes the results from seven different papers. The overall objective was to carefully and systematically study the emissions from residential biomass combustion with respect to: i) experimental characterization and quantification, ii) influences of fuel, appliance and operational variables and iii) aspects of ash and trace element transformations and aerosol formation. Special concern in the work was on sampling, quantification and characterization of particulate emissions using different appliances, fuels and operating procedures. An initial review of health effects showed epidemiological evidence of potential adverse effect from wood smoke exposure. A robust whole flow dilution sampling set-up for residential biomass appliances was then designed, constructed and evaluated, and subsequently used in the following emission studies. Extensive quantifications and characterizations of particulate and gases emissions were performed for residential wood and pellet appliances. Emission factor ranges for

  1. EPA ENERGY STAR: Tackling Growth in Home Electronics and Small Appliances

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, Marla Christine; Brown, Richard; Homan, Gregory

    2008-11-17

    Over a decade ago, the electricity consumption associated with home electronics and other small appliances emerged onto the global energy policy landscape as one of the fastest growing residential end uses with the opportunity to deliver significant energy savings. As our knowledge of this end use matures, it is essential to step back and evaluate the degree to which energy efficiency programs have successfully realized energy savings and where savings opportunities have been missed.For the past fifteen years, we have quantified energy, utility bill, and carbon savings for US EPA?s ENERGY STAR voluntary product labeling program. In this paper, we present a unique look into the US residential program savings claimed to date for EPA?s ENERGY STAR office equipment, consumer electronics, and other small household appliances as well as EPA?s projected program savings over the next five years. We present a top-level discussion identifying program areas where EPA?s ENERGY STAR efforts have succeeded and program areas where ENERGY STAR efforts did not successfully address underlying market factors, technology issues and/or consumer behavior. We end by presenting the magnitude of ?overlooked? savings.

  2. Paying the full cost of power : an indicative comparative analysis of residential electricity rates across Canadian provinces

    International Nuclear Information System (INIS)

    Goulding, A.J.; Sabatier, G.

    2005-01-01

    This study was commissioned to review electricity rates charged to residential consumers across Canada and to determine how the basics of ratemaking change from province to province. Rates in each province vary significantly due to differences in the industry structure and their resource base. It was noted that direct comparisons are difficult because some rates reflect the financing, fuel and opportunity costs of power. For that reason, a simple adjustment factor was developed for fair comparison between jurisdictions. This assessment compared the all-in cost to final consumers which includes power generation, transmission, distribution and all other charges, as calculated by Statistics Canada. It was revealed that Alberta is Canada's only province where prices to final consumers reflect the market value of the underlying commodity. Ratepayers have the advantage of not being responsible for bad investment choices in the power sector and there are no hidden subsidies due to provincial ownership of power resources. Another consumer advantage is that they receive appropriate price signals in terms of energy consumption and conservation. This report suggests that low electricity rates in other provinces can be expected to rise much more rapidly than those in Alberta in the coming decade as consumers may be charged the full value of the electricity they use. 18 refs., 9 figs

  3. Assessment of Literature Related to Combustion Appliance Venting Systems

    Energy Technology Data Exchange (ETDEWEB)

    Rapp, V. H.; Less, B. D.; Singer, B. C.; Stratton, J. C.; Wray, C. P.

    2015-02-01

    In many residential building retrofit programs, air tightening to increase energy efficiency is often constrained by safety concerns with naturally vented combustion appliances. Tighter residential buildings more readily depressurize when exhaust equipment is operated, making combustion appliances more prone to backdraft or spill combustion exhaust into the living space. Several measures, such as installation guidelines, vent sizing codes, and combustion safety diagnostics, are in place with the intent to prevent backdrafting and combustion spillage, but the diagnostics conflict and the risk mitigation objective is inconsistent. This literature review summarizes the metrics and diagnostics used to assess combustion safety, documents their technical basis, and investigates their risk mitigations. It compiles information from the following: codes for combustion appliance venting and installation; standards and guidelines for combustion safety diagnostics; research evaluating combustion safety diagnostics; research investigating wind effects on building depressurization and venting; and software for simulating vent system performance.

  4. The Design, Construction, and Experimental Evaluation of a Compact Thermoacoustic-Stirling Engine Generator for Use in a micro-CHP Appliance

    Science.gov (United States)

    Wilcox, Douglas A., Jr.

    Micro combined heat and power or micro-CHP is the simultaneous generation of useful heat and electricity on a residential scale. The heat and electricity are produced at the point of use, avoiding the distribution losses associated with a centralized power plant. These appliances combine a conventional gas-fired condensing boiler with an electric power module capable of generating electricity from the heat of combustion. Currently, the leading power modules for micro-CHP appliances are free-piston Stirling engines (FPSEs) which can generate 1050 watts of electricity at a thermal-to-electric efficiency of 26%.[1] These external combustion engines have been under development for the last 25 years, with FPSE micro-CHP appliances only recently being introduced to the commercial market. Publications by developers assert unlimited service life and high efficiency, with low noise and emissions; but despite these claims, the actual reliability and cost of manufacturing has prevented their successful mass-market adoption. A Thermoacoustic-Stirling Engine Generator or TaSEG is one possible alternative to FPSE's. A TaSEG uses a thermoacoustic engine, or acoustic heat engine, which can efficiently convert high temperature heat into acoustic power while maintaining a simple design with fewer moving parts than traditional FPSE's. This simpler engine is coupled to an electrodynamic alternator capable of converting acoustic power into electricity. This thesis outlines the design, construction, and experimental evaluation of a TaSEG which is appropriate for integration with a gas burner inside of a residential micro- CHP appliance. The design methodology is discussed, focusing on how changes in the geometry affected the predicted performance. Details of its construction are given and the performance of the TaSEG is then outlined. The TaSEG can deliver 132 watts of electrical output power to an electric load with an overall measured thermal-to-electric (first law) efficiency of eta

  5. Effects of feedback on residential electricity demand—Findings from a field trial in Austria

    International Nuclear Information System (INIS)

    Schleich, Joachim; Klobasa, Marian; Gölz, Sebastian; Brunner, Marc

    2013-01-01

    This paper analyzes the effects of providing feedback on electricity consumption in a field trial involving more than 1500 households in Linz, Austria. About half of these households received feedback together with information about electricity-saving measures (pilot group), while the remaining households served as a control group. Participation in the pilot group was random, but households were able to choose between two types of feedback: access to a web portal or written feedback by post. Results from cross section OLS regression suggest that feedback provided to the pilot group corresponds with electricity savings of around 4.5% for the average household. Our results from quantile regressions imply that for households in the 30th to the 70th percentile of electricity consumption, feedback on electricity consumption is statistically significant and effects are highest in absolute terms and as a share of electricity consumption. For percentiles below or above this range, feedback appears to have no effect. Finally, controlling for a potential endogeneity bias induced by non random participation in the feedback type groups, we find no difference in the effects of feedback provided via the web portal and by post. - Highlights: • We estimate the effects of feedback on household electricity use in a field trial in Linz, Austria. • Providing feedback on electricity use corresponds with average savings of around 4.5%. • Effects of feedback are most pronounced in the 30th to the 70th percentile. • Feedback provided via a web portal and by post appears equally effective

  6. The opening of electricity and gas markets to residential customers. Annual barometer - First wave. December 2007

    International Nuclear Information System (INIS)

    2007-01-01

    Since July 1, 2007, French residential customers can freely chose their energy supplier. A quantitative inquiry has been carried out by LH2 on behalf of the French Energy Regulatory Commission (CRE) on a sample of 1501 households representative of the overall French households. The aim of this barometer is to answer the following questions: what is the level of knowledge and information of individuals about the opening of energy markets and the new regulation in force? How do they perceive this opening? What is their behaviour in front of the opening of markets to competition? Four years after the full opening of energy markets, this first inquiry has permitted to draw up a first status of the knowledge, behaviour and opinion of individuals with respect to the opening of these markets. (J.S.)

  7. Optimum residential load management strategy for real time pricing (RTP) demand response programs

    International Nuclear Information System (INIS)

    Lujano-Rojas, Juan M.; Monteiro, Cláudio; Dufo-López, Rodolfo; Bernal-Agustín, José L.

    2012-01-01

    This paper presents an optimal load management strategy for residential consumers that utilizes the communication infrastructure of the future smart grid. The strategy considers predictions of electricity prices, energy demand, renewable power production, and power-purchase of energy of the consumer in determining the optimal relationship between hourly electricity prices and the use of different household appliances and electric vehicles in a typical smart house. The proposed strategy is illustrated using two study cases corresponding to a house located in Zaragoza (Spain) for a typical day in summer. Results show that the proposed model allows users to control their diary energy consumption and adapt their electricity bills to their actual economical situation. - Highlights: ► This work shows an optimal load management strategy for residential consumers. ► It has been considered the communication infrastructure of the future smart grid. ► A study case shows the optimal utilization of some appliances and electric vehicles. ► Results showed that the proposed model allows users to reduce their electricity bill.

  8. Mining residential water and electricity demand data in Southern California to inform demand management strategies

    Science.gov (United States)

    Cominola, A.; Spang, E. S.; Giuliani, M.; Castelletti, A.; Loge, F. J.; Lund, J. R.

    2016-12-01

    Demand side management strategies are key to meet future water and energy demands in urban contexts, promote water and energy efficiency in the residential sector, provide customized services and communications to consumers, and reduce utilities' costs. Smart metering technologies allow gathering high temporal and spatial resolution water and energy consumption data and support the development of data-driven models of consumers' behavior. Modelling and predicting resource consumption behavior is essential to inform demand management. Yet, analyzing big, smart metered, databases requires proper data mining and modelling techniques, in order to extract useful information supporting decision makers to spot end uses towards which water and energy efficiency or conservation efforts should be prioritized. In this study, we consider the following research questions: (i) how is it possible to extract representative consumers' personalities out of big smart metered water and energy data? (ii) are residential water and energy consumption profiles interconnected? (iii) Can we design customized water and energy demand management strategies based on the knowledge of water- energy demand profiles and other user-specific psychographic information? To address the above research questions, we contribute a data-driven approach to identify and model routines in water and energy consumers' behavior. We propose a novel customer segmentation procedure based on data-mining techniques. Our procedure consists of three steps: (i) extraction of typical water-energy consumption profiles for each household, (ii) profiles clustering based on their similarity, and (iii) evaluation of the influence of candidate explanatory variables on the identified clusters. The approach is tested onto a dataset of smart metered water and energy consumption data from over 1000 households in South California. Our methodology allows identifying heterogeneous groups of consumers from the studied sample, as well as

  9. The effects of electric vehicles on residential households in the city of Indianapolis

    International Nuclear Information System (INIS)

    Huang Shisheng; Safiullah, Hameed; Xiao Jingjie; Hodge, Bri-Mathias S.; Hoffman, Ray; Soller, Joan; Jones, Doug; Dininger, Dennis; Tyner, Wallace E.; Liu, Andrew; Pekny, Joseph F.

    2012-01-01

    There is an increasing impetus to transform the U.S transportation sector and transition away from the uncertainties of oil supply. One of the most viable current solutions is the adoption of electric vehicles (EVs). These vehicles allow for a transportation system that would be flexible in its fuel demands. However, utilities may need to address questions such as distribution constraints, electricity tariffs and incentives and public charging locations before large scale electric vehicle adoption can be realized. In this study, the effect of electric vehicles on households in Indianapolis is examined. A four-step traffic flow model is used to characterize the usage characteristics of vehicles in the Indianapolis metropolitan area. This data is then used to simulate EV usage patterns which can be used to determine household electricity usage characteristics. These results are differentiated by the zones with which the households are associated. Economic costs are then calculated for the individual households. Finally, possible public charging locations are examined. - Highlights: ► Traffic flow modeling is used to accurately characterize EV usage in Indianapolis. ► EV usage patterns are simulated to determine household electricity usage patterns. ► Economic costs are calculated for the households for electric vehicles. ► Possible public charging locations are examined.

  10. Residential Consumption Scheduling Based on Dynamic User Profiling

    Science.gov (United States)

    Mangiatordi, Federica; Pallotti, Emiliano; Del Vecchio, Paolo; Capodiferro, Licia

    Deployment of household appliances and of electric vehicles raises the electricity demand in the residential areas and the impact of the building's electrical power. The variations of electricity consumption across the day, may affect both the design of the electrical generation facilities and the electricity bill, mainly when a dynamic pricing is applied. This paper focuses on an energy management system able to control the day-ahead electricity demand in a residential area, taking into account both the variability of the energy production costs and the profiling of the users. The user's behavior is dynamically profiled on the basis of the tasks performed during the previous days and of the tasks foreseen for the current day. Depending on the size and on the flexibility in time of the user tasks, home inhabitants are grouped in, one over N, energy profiles, using a k-means algorithm. For a fixed energy generation cost, each energy profile is associated to a different hourly energy cost. The goal is to identify any bad user profile and to make it pay a highest bill. A bad profile example is when a user applies a lot of consumption tasks and low flexibility in task reallocation time. The proposed energy management system automatically schedules the tasks, solving a multi-objective optimization problem based on an MPSO strategy. The goals, when identifying bad users profiles, are to reduce the peak to average ratio in energy demand, and to minimize the energy costs, promoting virtuous behaviors.

  11. Assessing consumer benefits of selected gas appliance technology center tasks. Topical report, April-December 1992

    International Nuclear Information System (INIS)

    Smith, T.R.; Bournakis, A.D.; Worek, W.M.; Kalensky, D.C.; Dombrowski, L.P.

    1992-12-01

    The Gas Appliance Technology Center (GATC) was created in 1983 to assist the gas industry in bringing about a new generation of reasonably priced, advanced gas appliances. The objective of the report is to evaluate consumer benefits of sixteen selected GATC tasks for the time period between 1983 and 1990. Tasks were selected for review based upon their degree of industry impact and how well they represented activities in the four targeted research areas of Space Conditioning, Commercial Appliances, Residential Appliances, and Codes and Standards

  12. Realizing potential savings of energy and emissions from efficient household appliances in India

    International Nuclear Information System (INIS)

    Parikh, Kirit S.; Parikh, Jyoti K.

    2016-01-01

    The paper projects households' stock of four major electricity consuming appliances till 2030 and explores policy options to accelerate adoption of more energy efficient appliances. India's rapid economic growth has enabled the growing middle class to buy household appliances in increasing numbers. The consequent rise in energy consumption and GHG emissions can be significantly reduced if consumers are motivated by awareness and options in the market to buy energy efficient appliances. India has introduced a star rating scheme for appliances, and even without incentives consumers purchase star-rated appliances. The stock of household appliances is projected using the data of a national sample survey of household consumption, observed sale of star-rated appliances and projected consumption distribution. Estimated savings in households' electricity consumption from just four appliances, ACs, refrigerators, TVs, and ceiling fans, for which data were available, range from 52 bKwh to 145 bkwh in 2030, reductions of 10–27%. The corresponding reduction in CO_2 emissions will be between 42 Mt and 116 Mt in 2030. With policies of finance and bulk procurement to reduce costs, emissions reduction can be 128 Mt in 2030, a reduction of 30%. - Highlights: • Estimates the stock of selected household appliances with 20 classes of rural and urban households in the years 2030 in India. • Assesses the economics of energy efficient appliances. • Estimates spread of selected energy efficient appliances. • Assesses savings in energy consumption and CO_2 emissions in four alternative scenarios. • Suggests policies to promote energy efficient appliances.

  13. Efficient Energy Management for a Grid-Tied Residential Microgrid

    DEFF Research Database (Denmark)

    Anvari-Moghaddam, Amjad; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez

    2017-01-01

    generation characteristics, heat transfer and thermal dynamics of sustainable residential buildings and load scheduling potentials of household appliances with associated constraints. Through various simulation studies under different working scenarios with real data, different system constraints and user...

  14. SIZING AND COSTING OPTIMISATION OF A TYPICAL WIND/PV HYBRID ELECTRICITY GENERATION SYSTEM FOR A TYPICAL RESIDENTIAL BUILDING IN URBAN ARMIDALE NSW, AUSTRALIA

    Directory of Open Access Journals (Sweden)

    Yasser Maklad

    2014-04-01

    Full Text Available This study investigates the wind and solar electricity generation availability and potentiality for residential buildings in Armidale NSW, Australia. The main purpose of this study is to design an appropriate wind-PV hybrid system to cover the electricity consumption of typical residential buildings of various occupancy rates and relevant various average electrical daily consumption. In order to do achieve that, monthly average solar irradiance monthly average wind speed historical data observed at weather station belongs to the Australian bureau of meteorology in Armidale town over a fourteen years period from 1997–2010. Simulation of solar photovoltaic panels and wind turbines were conducted to obtain the optimal hybrid system sizing and best efficient with lowest cost. Correlations between the solar and wind power data were carried out on an hourly, daily, and monthly basis. It is shown that the hybrid system can be applied for the efficient and economic utilization of wind and solar renewable energy sources.

  15. Dynamic pricing of electricity for residential customers. The evidence from Michigan

    Energy Technology Data Exchange (ETDEWEB)

    Faruqui, A.; Akaba, L. [The Brattle Group, 201 Mission Street, Suite 2800, San Francisco, CA 94105 (United States); Sergici, S. [The Brattle Group, 44 Brattle Street, Cambridge, MA 02138 (United States)

    2013-08-15

    The rollout of smart meters has enabled the provision of dynamic pricing to residential customers. However, doubts remain whether households can respond to time-varying price signals and that is preventing the full-scale rollout of dynamic pricing and the attainment of economic efficiency. Experiments are being conducted to test price responsiveness. We analyze data from a pilot in Michigan which featured two dynamic pricing rates and an enabling technology. Unlike most other pilots, it also included a group of 'information only' customers who were provided information on time-varying prices but billed on standard rates. Similarly, unlike most other pilots, it also included two control groups, one of whom knew they were in the pilot and one of whom did not. This was designed to test for the presence of a Hawthorne effect. Consistent with the large body of experimental literature, we find that customers, including low-income participants, do respond to dynamic pricing. We also find that the response to critical peak pricing rates is similar to the response to peak time rebates, consistent with the finding of one prior experiment but inconsistent with the finding of two prior experiments. We also find that the 'information only' customers respond to the provision of pricing information but at a substantially lower rate than the customers on dynamic pricing. We find that the response to enabling technology is muted. We do not find any evidence to suggest that a Hawthorne effect existed in this experiment.

  16. Uncertainties in the Value of Bill Savings from Behind-the-Meter, Residential Photovoltaic Systems: The Roles of Electricity Market Conditions, Retail Rate Design, and Net Metering

    Science.gov (United States)

    Darghouth, Naim Richard

    Net metering has become a widespread policy mechanism in the U.S. for supporting customer adoption of distributed photovoltaics (PV), allowing customers with PV systems to reduce their electric bills by offsetting their consumption with PV generation, independent of the timing of the generation relative to consumption. Although net metering is one of the principal drivers for the residential PV market in the U.S., the academic literature on this policy has been sparse and this dissertation contributes to this emerging body of literature. This dissertation explores the linkages between the availability of net metering, wholesale electricity market conditions, retail rates, and the residential bill savings from behind-the-meter PV systems. First, I examine the value of the bill savings that customers receive under net metering and alternatives to net metering, and the associated role of retail rate design, based on current rates and a sample of approximately two hundred residential customers of California's two largest electric utilities. I find that the bill savings per kWh of PV electricity generated varies greatly, largely attributable to the increasing block structure of the California utilities' residential retail rates. I also find that net metering provides significantly greater bill savings than alternative compensation mechanisms based on avoided costs. However, retail electricity rates may shift as wholesale electricity market conditions change. I then investigate a potential change in market conditions -- increased solar PV penetrations -- on wholesale prices in the short-term based on the merit-order effect. This demonstrates the potential price effects of changes in market conditions, but also points to a number of methodological shortcomings of this method, motivating my usage of a long-term capacity investment and economic dispatch model to examine wholesale price effects of various wholesale market scenarios in the subsequent analysis. By developing

  17. When do energy-efficient appliances generate energy savings? Some evidence from Canada

    International Nuclear Information System (INIS)

    Young, Denise

    2008-01-01

    Improvements in the energy efficiency of household appliances have the potential to decrease residential energy use, but these reductions accrue gradually over time as newer appliances replace older models. SHEU-2003 data are used to examine appliance replacement patterns in Canada for refrigerators, freezers, dishwashers, clothes washers and clothes dryers. The data indicate that the ages at which appliances are replaced tend to be lowest for dishwashers and highest for freezers, with over 40% of freezers in use for more than 20 years before being retired. The life spans of Canadian appliances are compared to the underlying assumptions regarding appliance lifetimes used in models of residential energy demand. We find that Canadian appliance retirement patterns differ from those assumed in the previous literature. Socioeconomic factors related to appliance replacement are also examined. We find that replacement patterns can be sensitive to household characteristics such as income, providing evidence that there may be scope for targeted policies aimed at inducing earlier replacements of older household appliances with new energy-efficient models

  18. Residential energy use and conservation in Venezuela: Results and implications of a household survey in Caracas

    Energy Technology Data Exchange (ETDEWEB)

    Figueroa, M.J.; Ketoff, A.; Masera, O.

    1992-10-01

    This document presents the final report of a study of residential energy use in Caracas, the capital of Venezuela. It contains the findings of a household energy-use survey held in Caracas in 1988 and examines options for introducing energy conservation measures in the Venezuelan residential sector. Oil exports form the backbone of the Venezuelan economy. Improving energy efficiency in Venezuela will help free domestic oil resources that can be sold to the rest of the world. Energy conservation will also contribute to a faster recovery of the economy by reducing the need for major investments in new energy facilities, allowing the Venezuelan government to direct its financial investments towards other areas of development. Local environmental benefits will constitute an important additional by-product of implementing energy-efficiency policies in Venezuela. Caracas`s residential sector shows great potential for energy conservation. The sector is characterized by high saturation levels of major appliances, inefficiency of appliances available in the market, and by careless patterns of energy use. Household energy use per capita average 6.5 GJ/per year which is higher than most cities in developing countries; most of this energy is used for cooking. Electricity accounts for 41% of all energy use, while LPG and natural gas constitute the remainder. Specific options for inducing energy conservation and energy efficiency in Caracas`s residential sector include energy-pricing policies, fuel switching, particularly from electricity to gas, improving the energy performance of new appliances and customer information. To ensure the accomplishment of an energy-efficiency strategy, a concerted effort by energy users, manufacturers, utility companies, government agencies, and research institutions will be needed.

  19. A Framework for Understanding and Generating Integrated Solutions for Residential Peak Energy Demand

    Science.gov (United States)

    Buys, Laurie; Vine, Desley; Ledwich, Gerard; Bell, John; Mengersen, Kerrie; Morris, Peter; Lewis, Jim

    2015-01-01

    Supplying peak energy demand in a cost effective, reliable manner is a critical focus for utilities internationally. Successfully addressing peak energy concerns requires understanding of all the factors that affect electricity demand especially at peak times. This paper is based on past attempts of proposing models designed to aid our understanding of the influences on residential peak energy demand in a systematic and comprehensive way. Our model has been developed through a group model building process as a systems framework of the problem situation to model the complexity within and between systems and indicate how changes in one element might flow on to others. It is comprised of themes (social, technical and change management options) networked together in a way that captures their influence and association with each other and also their influence, association and impact on appliance usage and residential peak energy demand. The real value of the model is in creating awareness, understanding and insight into the complexity of residential peak energy demand and in working with this complexity to identify and integrate the social, technical and change management option themes and their impact on appliance usage and residential energy demand at peak times. PMID:25807384

  20. Consumption of electric power for space heating of residential buildings and other premises

    International Nuclear Information System (INIS)

    Sandberg, E.; Westerlund, R.

    1986-10-01

    The analysis comprises power consumption to 1989 and to 1997 using different energy prices. The effects of oil prices on consumption has been calculated. The level of the consumption of electric power of the year 1989 is estimated to be 2-3 TWh higher than the level of 1997. This is because of not yet accomplished economizing measures and relatively new installations

  1. The role of energy and investment literacy for residential electricity demand and end-use efficiency

    NARCIS (Netherlands)

    Blasch, J.E.; Boogen, Nina; Filippini, Massimo; Kumar, Nilkanth

    2017-01-01

    This paper estimates the level of transient and persistent efficiency in the use of electricity in Swiss households using the newly developed generalized true random effects model (GTREM). An unbalanced panel dataset of 1, 994 Swiss households from 2010 to 2014 collected via a household survey is

  2. Analysis of PG&E`s residential end-use metered data to improve electricity demand forecasts -- final report

    Energy Technology Data Exchange (ETDEWEB)

    Eto, J.H.; Moezzi, M.M.

    1993-12-01

    This report summarizes findings from a unique project to improve the end-use electricity load shape and peak demand forecasts made by the Pacific Gas and Electric Company (PG&E) and the California Energy Commission (CEC). First, the direct incorporation of end-use metered data into electricity demand forecasting models is a new approach that has only been made possible by recent end-use metering projects. Second, and perhaps more importantly, the joint-sponsorship of this analysis has led to the development of consistent sets of forecasting model inputs. That is, the ability to use a common data base and similar data treatment conventions for some of the forecasting inputs frees forecasters to concentrate on those differences (between their competing forecasts) that stem from real differences of opinion, rather than differences that can be readily resolved with better data. The focus of the analysis is residential space cooling, which represents a large and growing demand in the PG&E service territory. Using five years of end-use metered, central air conditioner data collected by PG&E from over 300 residences, we developed consistent sets of new inputs for both PG&E`s and CEC`s end-use load shape forecasting models. We compared the performance of the new inputs both to the inputs previously used by PG&E and CEC, and to a second set of new inputs developed to take advantage of a recently added modeling option to the forecasting model. The testing criteria included ability to forecast total daily energy use, daily peak demand, and demand at 4 P.M. (the most frequent hour of PG&E`s system peak demand). We also tested the new inputs with the weather data used by PG&E and CEC in preparing their forecasts.

  3. Residential Fuel Cell Demonstration Handbook: National Rural Electric Cooperative Association Cooperative Research Network

    Energy Technology Data Exchange (ETDEWEB)

    Torrero, E.; McClelland, R.

    2002-07-01

    This report is a guide for rural electric cooperatives engaged in field testing of equipment and in assessing related application and market issues. Dispersed generation and its companion fuel cell technology have attracted increased interest by rural electric cooperatives and their customers. In addition, fuel cells are a particularly interesting source because their power quality, efficiency, and environmental benefits have now been coupled with major manufacturer development efforts. The overall effort is structured to measure the performance, durability, reliability, and maintainability of these systems, to identify promising types of applications and modes of operation, and to assess the related prospect for future use. In addition, technical successes and shortcomings will be identified by demonstration participants and manufacturers using real-world experience garnered under typical operating environments.

  4. Electricity, water, and natural gas consumption of a residential house in Canada from 2012 to 2014

    Science.gov (United States)

    Makonin, Stephen; Ellert, Bradley; Bajić, Ivan V.; Popowich, Fred

    2016-06-01

    With the cost of consuming resources increasing (both economically and ecologically), homeowners need to find ways to curb consumption. The Almanac of Minutely Power dataset Version 2 (AMPds2) has been released to help computational sustainability researchers, power and energy engineers, building scientists and technologists, utility companies, and eco-feedback researchers test their models, systems, algorithms, or prototypes on real house data. In the vast majority of cases, real-world datasets lead to more accurate models and algorithms. AMPds2 is the first dataset to capture all three main types of consumption (electricity, water, and natural gas) over a long period of time (2 years) and provide 11 measurement characteristics for electricity. No other such datasets from Canada exist. Each meter has 730 days of captured data. We also include environmental and utility billing data for cost analysis. AMPds2 data has been pre-cleaned to provide for consistent and comparable accuracy results amongst different researchers and machine learning algorithms.

  5. Information v. energy efficiency incentives: Evidence from residential electricity consumption in Maryland

    International Nuclear Information System (INIS)

    Alberini, Anna; Towe, Charles

    2015-01-01

    We focus on two utility programs intended to reduce energy usage and the associated CO2 emissions—a home energy audit and rebates on the purchase of high-efficiency air-source heat pumps. We use a unique panel dataset from participating and non-participating households to estimate the average treatment effect of participating in either program on electricity usage. We fit models with household-by-season, season-by-year, and household-by-year fixed effects to account for all possible confounders that might influence energy usage. Since the programs are voluntary, we seek to restore near-exogeneity of the program “treatment” by matching participating households with control households. We deploy coarsened exact matching (CEM; Iacus et al., 2011) as our main matching method. We ask whether it is sufficient to match households based on past electricity usage, or if we gain by adding structural characteristics of the home, including heating system type. We find that the two programs reduce electricity usage by 5% on average. The effects are strong in both winter and summer for the energy audit groups but appear to be stronger in the winter for the heat pump rebate group. Adding house characteristics to the matching variables does seem to affect results, suggesting that using past usage alone, or house characteristics alone, may not be sufficient to identify the effects of program participation.

  6. Analysis of the electrical bills of residential consumers: tax and economic aspects; Analise da fatura de energia eletrica de consumidores residenciais: aspectos economicos e tributarios

    Energy Technology Data Exchange (ETDEWEB)

    Reis, Lindemberg Nunes; Pinto, Danilo Pereira [Universidade Federal de Juiz de Fora, MG (Brazil). Fac. de Engenharia], e-mail: lnunesreis@yahoo.com.br, e-mail: danilo.pinto@ufjf.edu.br

    2008-07-01

    Residential consumers represent a significant part of the market of electric energy and are increasing by deriving tributes of the tariff of energy. These consumers are uninformed about the abuses that happen to them. This work has as objective to analyze and to argue the behavior of the tariffs of energy in the period of 2002 the 2006, demonstrating the occurred increases and pointing a relation enters the rise of the price of this energy and the increase of the number of clandestine linkings and difficulty to hold the basics statements of actually electrical regiments. ANEEL's data show that in 1995 the tariff for class residential was R$ 76.26 and industrial was R$ 43.59; in 2003 passed respectively to R$ 236.34 and R$ 110.48. This analysis is directly related to the difficulty of obtaining a national energy management totally sustainable. (author)

  7. Crew appliance study

    Science.gov (United States)

    Proctor, B. W.; Reysa, R. P.; Russell, D. J.

    1975-01-01

    Viable crew appliance concepts were identified by means of a thorough literature search. Studies were made of the food management, personal hygiene, housekeeping, and off-duty habitability functions to determine which concepts best satisfy the Space Shuttle Orbiter and Modular Space Station mission requirements. Models of selected appliance concepts not currently included in the generalized environmental-thermal control and life support systems computer program were developed and validated. Development plans of selected concepts were generated for future reference. A shuttle freezer conceptual design was developed and a test support activity was provided for regenerative environmental control life support subsystems.

  8. AWARENESS ON ENERGY MANAGEMENT IN RESIDENTIAL BUILDINGS: A CASE STUDY IN KAJANG AND PUTRAJAYA

    Directory of Open Access Journals (Sweden)

    MAYTHAM S. AHMED

    2017-05-01

    Full Text Available This paper presents a case study on a survey and measurement being carried out for the purpose of determining residential electric power consumption and awareness toward smart energy management system in the areas of Putrajaya and Kajang, Malaysia. Questionnaires were developed with 37 questions grouped in 5 different sections related to home appliance information. Data was collected from a sample size of 384 respondents with confidence level of 95%. The accuracy of the percentage energy usage data were analysed by applying the SPSS software. Actual residential electric power consumption was measured by using a power quality analyser to determine the total power consumption at weekday and weekend and power consumption of each electrical appliance. The measurement results showed that the average energy consumption is 25.8 kWh/day during weekend and 21.9 kWh/day during weekdays with 11.5 kWh/day for the air conditioner only. The survey results revealed that 89.06% of the respondents expressed awareness toward household power consumption and that they are willing to install home automation system to reducing their electricity bill.

  9. Uncertainties in the Value of Bill Savings from Behind-the-Meter, Residential Photovoltaic Systems: The Roles of Electricity Market Conditions, Retail Rate Design, and Net Metering

    OpenAIRE

    Darghouth, Naim Richard

    2013-01-01

    Net metering has become a widespread policy mechanism in the U.S. for supporting customer adoption of distributed photovoltaics (PV), allowing customers with PV systems to reduce their electric bills by offsetting their consumption with PV generation, independent of the timing of the generation relative to consumption. Although net metering is one of the principal drivers for the residential PV market in the U.S., the academic literature on this policy has been sparse and this dissertation co...

  10. Residential-energy-demand modeling and the NIECS data base: an evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Cowing, T.G.; Dubin, J.A.; McFadden, D.

    1982-01-01

    The purpose of this report is to evaluate the 1978-1979 National Interim Energy Consumption Survey (NIECS) data base in terms of its usefulness for estimating residential energy demand models based on household appliance choice and utilization decisions. The NIECS contains detailed energy usage information at the household level for 4081 households during the April 1978 to March 1979 period. Among the data included are information on the structural and thermal characteristics of the housing unit, demographic characteristics of the household, fuel usage, appliance characteristics, and actual energy consumption. The survey covers the four primary residential fuels-electricity, natural gas, fuel oil, and liquefied petroleum gas - and includes detailed information on recent household conservation and retrofit activities. Section II contains brief descriptions of the major components of the NIECS data set. Discussions are included on the sample frame and the imputation procedures used in NIECS. There are also two extensive tables, giving detailed statistical and other information on most of the non-vehicle NIECS variables. Section III contains an assessment of the NIECS data, focusing on four areas: measurement error, sample design, imputation problems, and additional data needed to estimate appliance choice/use models. Section IV summarizes and concludes the report.

  11. Linear triangular optimization technique and pricing scheme in residential energy management systems

    Science.gov (United States)

    Anees, Amir; Hussain, Iqtadar; AlKhaldi, Ali Hussain; Aslam, Muhammad

    2018-06-01

    This paper presents a new linear optimization algorithm for power scheduling of electric appliances. The proposed system is applied in a smart home community, in which community controller acts as a virtual distribution company for the end consumers. We also present a pricing scheme between community controller and its residential users based on real-time pricing and likely block rates. The results of the proposed optimization algorithm demonstrate that by applying the anticipated technique, not only end users can minimise the consumption cost, but it can also reduce the power peak to an average ratio which will be beneficial for the utilities as well.

  12. Hybrid renewable energy system application for electricity and heat supply of a residential building

    Directory of Open Access Journals (Sweden)

    Nakomčić-Smaragdakis Branka B.

    2016-01-01

    Full Text Available Renewable and distributed energy systems could provide a solution to the burning issue of reliable and clean supply of energy, having in mind current state and future predictions for population growth and fossil fuel scarcity. Hybrid renewable energy systems are novelty in Serbia and warrant further detailed research. The aim of this paper is to analyze the application of renewable energy sources(RES for electricity and heat supply of a typical household in Serbia, as well as the cost-effectiveness of the proposed system. The influence of feed-in tariff change on the value of the investment is analyzed. Small, grid-connected hybrid system (for energy supply of a standard household, consisting of geothermal heat pump for heating/cooling, solar photovoltaic panels and small wind turbine for power supply is analyzed as a case study. System analysis was conducted with the help of RETScreen software. Results of techno-economics analysis have shown that investing in geothermal heat pump and photovoltaic panels is cost-effective, while that is not the case with small wind turbine.

  13. File System Virtual Appliances

    Science.gov (United States)

    2010-05-01

    4 KB of data is read or written, data is copied back and forth using trampoline buffers — pages that are shared during proxy initialization — because...in 2008. CIO Magazine. 104 · File system virtual appliances [64] Megiddo, N. and Modha, D. S. 2003. ARC: A Self-Tuning, Low Over- head Replacement

  14. Cost-competitiveness of organic photovoltaics for electricity self-consumption at residential buildings: A comparative study of Denmark and Greece under real market conditions

    DEFF Research Database (Denmark)

    Chatzisideris, Marios Dimos; Laurent, Alexis; Christoforidis, Georgios C.

    2017-01-01

    To address sustainability challenges, photovoltaics (PV) are regarded as a promising renewable energy technology. Decreasing PV module costs and increasing residential electricity prices have made self-consumption of PV-generated electricity financially more attractive than exporting to the grid....... Organic photovoltaics (OPV) are an emerging thin-film PV technology that shows promise of greatly improving the environmental and economic performances of PV technologies. Previous studies have estimated the current and future costs of OPV technologies, but the attractiveness of investing in OPV systems...

  15. Feasibility study on combined use of residential SOFC cogeneration system and plug-in hybrid electric vehicle from energy-saving viewpoint

    International Nuclear Information System (INIS)

    Wakui, Tetsuya; Wada, Naohiro; Yokoyama, Ryohei

    2012-01-01

    Highlights: ► Optimal operational planning for combined use of SOFC-CGS and PHEV is conducted. ► Charging PHEV with SOFC-CGS increases electric capacity factor of SOFC-CGS. ► Energy-saving effect of combined use is higher than that of their separate use. ► Combined use provides energy savings in both residential and transport sectors. - Abstract: The energy-saving effect of a combined use of a residential solid oxide fuel cell cogeneration system (SOFC-CGS) that adopts a continuous operation, and a plug-in hybrid electric vehicle (PHEV) is discussed by optimal operational planning based on mixed-integer linear programming. This combined use aims to increase the electric capacity factor of the SOFC-CGS by charging the PHEV using the SOFC-CGS electric power output late at night, and targets the application in regions where the reverse power flow from residential cogeneration systems to commercial electric power systems is not permitted, like in Japan. The optimal operation patterns of the combined use of 0.7-kWe SOFC-CGS and PHEV for a simulated energy demand with a sampling time of 1 h and various daily running distances of the PHEV show that this combined use increases the electric capacity factor of the SOFC-CGS and saves more energy in comparison with their separate use in which the SOFC-CGS is used but the PHEV is charged only with purchased electric power. Furthermore, it is found that at the PHEV daily running distance of 12 km/d, the reduction rate of the annual primary energy consumption for this combined use increases by up to 3.7 percentage points relative to their separate use. Consequently, this feasibility study reveals that the combined use of the SOFC-CGS and PHEV provides the synergistic effect on energy savings in the residential and transport sectors. For the practical use, simulation scenarios considering the energy demand fluctuations with short periods and real-time pricing of the purchased electric power must be considered as future

  16. Energy consumption of audiovisual devices in the residential sector: Economic impact of harmonic losses

    International Nuclear Information System (INIS)

    Santiago, I.; López-Rodríguez, M.A.; Gil-de-Castro, A.; Moreno-Munoz, A.; Luna-Rodríguez, J.J.

    2013-01-01

    In this work, energy losses and the economic consequences of the use of small appliances containing power electronics (PE) in the Spanish residential sector were estimated. Audiovisual devices emit harmonics, originating in the distribution system an increment in wiring losses and a greater demand in the total apparent power. Time Use Surveys (2009–10) conducted by the National Statistical Institute in Spain were used to obtain information about the activities occurring in Spanish homes regarding the use of audiovisual equipment. Moreover, measurements of different types of household appliances available in the PANDA database were also utilized, and the active and non-active annual power demand of these residential-sector devices were determined. Although a single audiovisual device has an almost negligible contribution, the aggregated actions of this type of appliances, whose total annual energy demand is greater than 4000 GWh, can be significant enough to be taken into account in any energy efficiency program. It was proven that a reduction in the total harmonic distortion in the distribution systems ranging from 50% to 5% can reduce energy losses significantly, with economic savings of around several million Euros. - Highlights: • Time Use Survey provides information about Spanish household electricity consumption. • The annual aggregated energy demand of audiovisual appliances is very significant. • TV use accounts for more than 80% of household audiovisual electricity consumption. • A reduction from 50% to 5% in the total harmonic distortion would have economic savings of around several million Euros. • Stricter regulations regarding harmonic emissions must be demanded

  17. A quantile approach to assess the effectiveness of the subsidy policy for energy-efficient home appliances: Evidence from Rizhao, China

    International Nuclear Information System (INIS)

    Yao, Xi-Long; Liu, Yang; Yan, Xiao

    2014-01-01

    A one-year subsidy program for energy-efficient home appliances has been implemented in China. We construct a dataset consisting of participant and non-participant households in both urban and rural areas of Rizhao city. By applying a quantile regression and counterfactual analysis, this study disentangles the impact of this subsidy program and inherent household attributes on per capita residential electricity consumption. First, contrary to the mean regression, the elasticity of electricity consumption to household's income, age, education and energy-saving awareness, varies markedly across the electricity consumption distribution and shows discrepancy between urban and rural areas. Second, while inherent household attributes are identified as a primary determinant to the changes in residential electricity consumption, the effect induced by the subsidy incentive is more significant at the middle of the electricity consumption distribution than at the tails. Third, there are significant rebound effects that lead to overall increase in household electricity consumption. Our results suggest that the disparity between urban and rural regions and targeted consumer behavior changes should be taken into account to ensure the effectiveness of a future energy-efficient subsidy program. - Highlights: • The effect of the subsidy policy on electricity consumption is assessed with a quantile regression. • Policy induced effect is more significant at the middle of the distribution than at the tails. • The rebound effects lead to overall increase in electricity consumption. • The impact of households attributes varies markedly across electricity consumption distribution

  18. Exposure from Appliances (invited paper)

    Energy Technology Data Exchange (ETDEWEB)

    Cartwright, R.A

    1999-07-01

    The dosemeter studies on exposures to ELF electromagnetic irradiation from domestic equipment all suggest the whole-body doses are low, whilst some exposure to extremities could be high but of brief duration. Old style electric overblankets, however, are an exception and produce high fields and relatively high whole-body doses if switched on during the night. Relatively few epidemiological studies have addressed these issues. All of the studies have associated problems of interpretations. Two isolated studies throw up on association with the frequency of spontaneous abortion and electric blanket use whilst another links adult AML and electric shaver usage. Both results could be fortuitous. More consistency appears from three studies of childhood leukaemia. Here statistically significant associations between electric blanket use in pregnancies appear in two separate studies, as does hair dryer use in the case of children: other appliances use associations have been reported. These results are critically assessed. The United Kingdom Childhood Cancer Study (UKCCS) addresses some of these issues as part of a wider ranging assessment of EMF at home and at school. External sources are incorporated with the measurement of domestic ambient conditions in an attempt to make an overall assessment of total exposure. (author)

  19. A High-Resolution Spatially Explicit Monte-Carlo Simulation Approach to Commercial and Residential Electricity and Water Demand Modeling

    Energy Technology Data Exchange (ETDEWEB)

    Morton, April M [ORNL; McManamay, Ryan A [ORNL; Nagle, Nicholas N [ORNL; Piburn, Jesse O [ORNL; Stewart, Robert N [ORNL; Surendran Nair, Sujithkumar [ORNL

    2016-01-01

    Abstract As urban areas continue to grow and evolve in a world of increasing environmental awareness, the need for high resolution spatially explicit estimates for energy and water demand has become increasingly important. Though current modeling efforts mark significant progress in the effort to better understand the spatial distribution of energy and water consumption, many are provided at a course spatial resolution or rely on techniques which depend on detailed region-specific data sources that are not publicly available for many parts of the U.S. Furthermore, many existing methods do not account for errors in input data sources and may therefore not accurately reflect inherent uncertainties in model outputs. We propose an alternative and more flexible Monte-Carlo simulation approach to high-resolution residential and commercial electricity and water consumption modeling that relies primarily on publicly available data sources. The method s flexible data requirement and statistical framework ensure that the model is both applicable to a wide range of regions and reflective of uncertainties in model results. Key words: Energy Modeling, Water Modeling, Monte-Carlo Simulation, Uncertainty Quantification Acknowledgment This manuscript has been authored by employees of UT-Battelle, LLC, under contract DE-AC05-00OR22725 with the U.S. Department of Energy. Accordingly, the United States Government retains and the publisher, by accepting the article for publication, acknowledges that the United States Government retains a non-exclusive, paid-up, irrevocable, world-wide license to publish or reproduce the published form of this manuscript, or allow others to do so, for United States Government purposes.

  20. Operational energy in the life cycle of residential dwellings: The experience of Spain and Colombia

    International Nuclear Information System (INIS)

    Ortiz, Oscar; Castells, Francesc; Sonnemann, Guido

    2010-01-01

    Life Cycle Assessment (LCA) has been applied within the residential building sector of two buildings, one in each a developed (Spain) and a developing (Colombia) country. The main goal of this paper involves the environmental loads and also brings together the operational energy for activities during the operation phase such as HVAC, domestic hot water, electrical appliances, cooking and illumination. The present research compares two real scenarios: Situation 1, where 100% of the dwelling's energy is supplied with electricity only and Situation 2, where dwellings can be operated with natural gas plus electricity. The results for the environmental impacts using natural gas plus electricity show that of the Spanish environmental impacts air conditioning had the highest impact with approximately 27-42% due to the electricity used to power it. In Colombian results showed that electrical appliances had the highest environmental impacts in the same order of magnitude with approximately 60% and cooking had the best reduction of emissions due to the use of natural gas, from 10% down to less than 2%. The origin of the energy source used in each Country plays an important role to minimize environmental impacts, as was demonstrated by the environmental impacts of its use in Colombia where 78% of the electricity came from hydroelectric plants whereas in Spain it is more mixed, fossil fuels represented 55%, nuclear 18% and wind 9%. In summary, LCA has been applied because this methodology supports the decision making to concern environmental sustainability.

  1. FY 2000 Development of technologies for reducing power consumption during the stand-by period. Report on the research and development results of rationally reducing power consumption by home electric appliances; 2000 nendo taikiji shohi denryoku sakugen gijutsu kaihatsu seika hokokusho. Kaden seihin no taikiji shohi denryoku no goriteki sakugen ni kansuru kenkyu kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    The research and development project is implemented for development of the system which automatically switches off the power source for a standing-by appliance by analyzing life pattern in each home, in order to reduce consumed power during the stand-by period. The actual service conditions of appliances in each home are surveyed through the questionnaires and recording in the diary. The analysis results indicate that as high as 70% of those who are inquired take interest in energy saving, especially high among full-time housewives. The home electric appliances considered by many to wastefully consume power are functional-keeping types, e.g., (jar pots) and (toilet seats equipped with a washing function with warm water), and heating appliances, e.g., (hot carpets). The power consumption trends at each time in each home are measured and grasped by the aid of a tool with built-in personal computer, and the algorithm for predicting use of the appliances in each home is developed for each home, based on the analysis results. The prototype energy-saving adapter and centralized controller are developed, and subjected to various tests to develop the learning/controlling algorithms. The demonstration tests of the energy-saving adapter developed confirm that power consumption during the stand-by period can be reduced at least by 10%. (NEDO)

  2. Technical and legal application possibilities of the compulsory labelling of the standby consumption of electrical household and office appliances - Project No. 53/03. Final report for the Federal Ministry of Economics and Labour; Technische und rechtliche Anwendungsmoeglichkeiten einer verpflichtenden Kennzeichnung des Leerlaufverbrauchs strombetriebener Haushalts- und Buerogeraete - Dienstleistungsvorhaben Nr. 53/03. Abschlussbericht an das Bundesministerium fuer Wirtschaft und Arbeit

    Energy Technology Data Exchange (ETDEWEB)

    Schlomann, B.; Cremer, C.; Friedewald, M. [Fraunhofer-Institut fuer Systemtechnik und Innovationsforschung, Karlsruhe (DE)] (and others)

    2005-04-27

    The standby consumption of electrical households and office appliances continues to be significant world-wide since the number of products with standby componen ts is constantly increasing. For Germany, a recent assessment of the Fraunhofer ISI (Cremer et al. 2003) for 2001 arrived at an electricity demand of almost 15 TWh for household and office appliances in standby mode. i.e. in standby and off -mode. This represents almost 40% of the total consumption of these appliances and around 3% of the total electricity demand of the final energy sectors in Ge rmany. The standby share in electricity demand is over 80 or even 90% for numer ous appliances. The Federal Environmental Agency calculated that every year stan dby losses in German households and offices are responsible for wasted electrici ty amounting to 3.5 billion Euro (UBA 2004). For the OECD countries, field studi es show that between 3 and 13% of the electricity consumption of households can be ascribed to standby losses (IEA 2001). Without energy policy measures on bot h national and international levels, there is a great risk that a further increa se in standby consumption will occur. Many studies dealing with this subject hav e already been conducted and have shown that low standby consumption is technica lly feasible and usually achievable at a reasonable cost. One possible energy po licy measure to reduce the standby consumption of electrical household and offic e appliances is the introduction of mandatory consumption labelling. In principl e, a high degree of effectiveness is attributed to such regulatory/command-and-c ontrol measures with regard to influencing the energy efficiency of devices. Com pulsory energy labels to identify and, where necessary, to classify electricity consumption produce greater market transparency and offer buyers an additional d ecision criterion. In this way they promote indirectly the development, producti on and supply of energy-efficient products. When combined with

  3. Saturation, energy consumption, CO{sub 2} emission and energy efficiency from urban and rural households appliances in Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Rosas-Flores, Jorge Alberto; Rosas-Flores, Dionicio [Division de Estudios de Posgrado, Facultad de Ingenieria, Universidad Nacional Autonoma de Mexico, Ciudad Universitaria Coyoacan 04510, Mexico, DF (Mexico); Posgrado de Arquitectura, Facultad de Arquitectura, Universidad Nacional Autonoma de Mexico, Ciudad Universitaria Coyoacan 04510, Mexico, DF (Mexico); Galvez, David Morillon [Posgrado de Arquitectura, Facultad de Arquitectura, Universidad Nacional Autonoma de Mexico, Ciudad Universitaria Coyoacan 04510, Mexico, DF (Mexico); Instituto de Ingenieria, Universidad Nacional Autonoma de Mexico, Ciudad, Universitaria, Coyoacan 04510, Mexico, DF (Mexico)

    2011-01-15

    Energy usage and energy efficiency are of increasing concern in Mexico, electricity generation principally depends upon fossil fuels. On one hand, the stocks of these fuels have been confirmed to be critically limited. On the other hand, in process of electricity generation by means of these fuels, a number of poisonous by-products adversely affect the conservation of natural eco-system. This paper focuses on estimation of energy consumption, energy savings, reduction of emissions of CO{sub 2} for use of urban and rural household appliances in Mexico between 1996 and 2021. The analysis concentrates on six major energy end uses in the residential sector: refrigerators, air conditioners, washing machines, TV set, iron and heater. It is estimated that by 2021 there will be a cumulative saving of 22,605 GWh, as a result of the implementation of government programs on energy efficiency that represents a cumulative reduction of CO{sub 2} emissions of 15,087 Tg CO{sub 2}. It means that Mexico can reduce in 5650 MW the generation capacity of national electricity system, which is to avoid burning 40.35 MM barrels of oil. The findings can be useful to policy makers as well as household appliances users. (author)

  4. Oral radiation protector appliance

    International Nuclear Information System (INIS)

    Persico, T.M.; Dudas, R.M.; Shusta, G.W.

    1982-01-01

    An appliance for protecting teeth, gingiva, periodontal or alveola bone, salivary glands, and adjacent body areas against the harmful side effects of radiation therapy consists of an intraoral portion and an extraoral portion that may be selectively attached. The intraoral portion is substantially u-shaped to encompass the teeth and adjacent areas. The intraoral part may be made of lead sheet coated with plastic; the extraoral portion may be of lead sheet

  5. Residential energy efficiency: Progress since 1973 and future potential

    Science.gov (United States)

    Rosenfeld, Arthur H.

    1985-11-01

    Today's 85 million U.S. homes use 100 billion of fuel and electricity (1150/home). If their energy intensity (resource energy/ft2) were still frozen at 1973 levels, they would use 18% more. With well-insulated houses, need for space heat is vanishing. Superinsulated Saskatchewan homes spend annually only 270 for space heat, 150 for water heat, and 400 for appliances, yet they cost only 2000±1000 more than conventional new homes. The concept of Cost of Conserved Energy (CCE) is used to rank conservation technologies for existing and new homes and appliances, and to develop supply curves of conserved energy and a least cost scenario. Calculations are calibrated with the BECA and other data bases. By limiting investments in efficiency to those whose CCE is less than current fuel and electricity prices, the potential residential plus commercial energy use in 2000 AD drops to half of that estimated by DOE, and the number of power plants needed drops by 200. For the whole buildings sector, potential savings by 2000 are 8 Mbod (worth 50B/year), at an average CCE of 10/barrel.

  6. The Next Generation of Appliances: Visions for Sustainability

    DEFF Research Database (Denmark)

    Nørgaard, Jørgen; Guldbrandsen, Tom

    1998-01-01

    to consume no more than 50 kWh per year, without using any risky synthetic gasses. Washing appliances will use no electricity for heating, which will bring annual electricity consumption below 50 kWh for a washing machine. For electronic equipment, the efficiency gain known from battery operated version...

  7. Characteristics of residential energy consumption in China: Findings from a household survey

    International Nuclear Information System (INIS)

    Zheng, Xinye; Wei, Chu; Qin, Ping; Guo, Jin; Yu, Yihua; Song, Feng; Chen, Zhanming

    2014-01-01

    A comprehensive survey of 1450 households in 26 Chinese provinces was undertaken in 2012 to identify the characteristics and potential driving forces of residential energy consumption in China. The survey covers six areas: household characteristics, dwelling characteristics, kitchen and home appliances, space heating and cooling, residential transportation, and electricity billing, metering, and pricing options. The results show that a typical Chinese household in 2012 consumed 1426 kilograms standard coal equivalent, which is approximately 44 percent of the 2009 level in the United States and 38 percent of the 2008 level in the EU-27. District heating, natural gas, and electricity are three major residential energy sources, while space heating, cooking, and water heating are three major end-use activities. Moreover, the results suggest a large urban–rural gap in terms of energy sources and purpose of usage. Commercial energy is used mainly for space heating in urban areas, while biomass dominates mainly for cooking purpose in rural areas. The survey results can help decision makers and scholars identify energy conservation opportunities, and evaluate the effectiveness of energy policies. - Highlights: • We develop the first comprehensive survey of residential energy consumption in China. • A typical Chinese household in 2012 consumed 1426 kilograms coal equivalent. • Space heating accounts for half of energy demand. • A large rural–urban gap exists in terms of energy sources and end-use activities. • Results reveal challenges and opportunities for China's energy policy

  8. The opening of electricity and natural gas markets to residential clients. Yearly barometer - run 4. September 2010

    International Nuclear Information System (INIS)

    2010-09-01

    The opening of energy markets to competition became effective to individuals ('residential clients') on July 1, 2007 with the possibility to freely choose their energy supplier. This opening of energy markets to residential clients started 3 years after the opening to professionals (July 1, 2004). The Commission of energy regulation (CRE) and the national energy Ombudsman have set in place in 2007 a quantitative yearly survey ('barometer') addressed to residential clients in order to collect statistical data about the behaviour of these clients with regards to the opening of markets to competition. This document deals with the results of the fourth run of this survey carried out from September 6 to September 18, 2010 by the LH2 institute. For the 1504 households investigated, LH2 has questioned the person in charge of the energy bills management. The barometer aimed at answering the following questions: - what is the level of knowledge and information of residential clients about markets opening and the existing regulation? - What perception of this opening do they have? (pros/cons, advantages/drawbacks); - what behaviour do they have in front of the opening of markets to competition? (approach with respect to information needs, knowledge about the offer, intention to change supplier, brakes/motivations in entering the open market). (J.S.)

  9. The opening of electricity and natural gas markets to residential clients. Yearly barometer - run 5. September 2011

    International Nuclear Information System (INIS)

    2011-09-01

    The opening of energy markets to competition became effective to individuals ('residential clients') on July 1, 2007 with the possibility to freely choose their energy supplier. This opening of energy markets to residential clients started 3 years after the opening to professionals (July 1, 2004). The Commission of energy regulation (CRE) and the national energy Ombudsman have set in place in 2007 a quantitative yearly survey ('barometer') addressed to residential clients in order to collect statistical data about the behaviour of these clients with regards to the opening of markets to competition. This document deals with the results of the fourth run of this survey carried out from September 12 to September 23, 2011 by the LH2 institute. For the 1500 households investigated, LH2 has questioned the person in charge of the energy bills management. The barometer aimed at answering the following questions: - what is the level of knowledge and information of residential clients about markets opening and the existing regulation? - What perception of this opening do they have? (pros/cons, advantages/drawbacks); - what behaviour do they have in front of the opening of markets to competition? (approach with respect to information needs, knowledge about the offer, intention to change supplier, brakes/motivations in entering the open market). (J.S.)

  10. The opening of electricity and natural gas markets to residential clients. Yearly barometer - run 3. September 2009

    International Nuclear Information System (INIS)

    2009-09-01

    The opening of energy markets to competition became effective to individuals ('residential clients') on July 1, 2007 with the possibility to freely choose their energy supplier. This opening of energy markets to residential clients started 3 years after the opening to professionals (July 1, 2004). The Commission of energy regulation (CRE) and the national energy Ombudsman have set in place in 2007 a quantitative yearly survey ('barometer') addressed to residential clients in order to collect statistical data about the behaviour of these clients with regards to the opening of markets to competition. This document deals with the results of the fourth run of this survey carried out in September 2009 by the LH2 institute. For the 1500 households investigated, LH2 has questioned the person in charge of the energy bills management. The barometer aimed at answering the following questions: - what is the level of knowledge and information of residential clients about markets opening and the existing regulation? - What perception of this opening do they have? (pros/cons, advantages/drawbacks); - what behaviour do they have in front of the opening of markets to competition? (approach with respect to information needs, knowledge about the offer, intention to change supplier, brakes/motivations in entering the open market). (J.S.)

  11. The opening of electricity and natural gas markets to residential clients. Yearly barometer - run 2. December 2008

    International Nuclear Information System (INIS)

    2008-12-01

    The opening of energy markets to competition became effective to individuals ('residential clients') on July 1, 2007 with the possibility to freely choose their energy supplier. This opening of energy markets to residential clients started 3 years after the opening to professionals (July 1, 2004). The Commission of energy regulation (CRE) and the national energy Ombudsman have set in place in 2007 a quantitative yearly survey ('barometer') addressed to residential clients in order to collect statistical data about the behaviour of these clients with regards to the opening of markets to competition. This document deals with the results of the fourth run of this survey carried out from November 10 to November 20, 2008 by the LH2 institute. For the 1502 households investigated, LH2 has questioned the person in charge of the energy bills management. The barometer aimed at answering the following questions: - what is the level of knowledge and information of residential clients about markets opening and the existing regulation? - What perception of this opening do they have? (pros/cons, advantages/drawbacks); - what behaviour do they have in front of the opening of markets to competition? (approach with respect to information needs, knowledge about the offer, intention to change supplier, brakes/motivations in entering the open market). (J.S.)

  12. Responsiveness of residential electricity demand to dynamic tariffs : experiences from a large field test in the Netherlands

    NARCIS (Netherlands)

    Klaassen, E.A.M.; Kobus, C.B.A.; Frunt, J.; Slootweg, J.G.

    2016-01-01

    To efficiently facilitate the energy transition it is essential to evaluate the potential of demand response in practice. Based on the results of a Dutch smart grid pilot, this paper assesses the potential of both manual and semi-automated demand response in residential areas. To stimulate demand

  13. Responsiveness of residential electricity demand to dynamic tariffs : Experiences from a large field test in the Netherlands

    NARCIS (Netherlands)

    Klaassen, EAM; Kobus, C.B.A.; Frunt, J; Slootweg, JG

    2016-01-01

    To efficiently facilitate the energy transition it is essential to evaluate the potential of demand response in practice. Based on the results of a Dutch smart grid pilot, this paper assesses the potential of both manual and semi-automated demand response in residential areas. To stimulate demand

  14. Learning from the implementation of residential optional time of use pricing in the United States electricity industry

    Science.gov (United States)

    Li, Xibao

    Residential time-of-use (TOU) rates have been in practice in the U.S. since the 1970s. However, for institutional, political, and regulatory reasons, only a very small proportion of residential customers are actually on these schedules. In this thesis, I explore why this is the case by empirically investigating two groups of questions: (1) On the "supply" side: Do utilities choose to offer TOU rates in residential sectors on their own initiative if state commissions do not order them to do so? Since utilities have other options, what is the relationship between the TOU rate and other alternatives? To answer these questions, I survey residential tariffs offered by more than 100 major investor-owned utilities, study the impact of various factors on utilities' rate-making behavior, and examine utility revealed preferences among four rate options: seasonal rates, inverted block rates, demand charges, and TOU rates. Estimated results suggest that the scale of residential sectors and the revenue contribution from residential sectors are the only two significant factors that influence utility decisions on offering TOU rates. Technical and economic considerations are not significant statistically. This implies that the little acceptance of TOU rates is partly attributed to utilities' inadequate attention to TOU rate design. (2) On the "demand" side: For utilities offering TOU tariffs, why do only a very small proportion of residential customers choose these tariffs? What factors influence customer choices? Unlike previous studies that used individual-level experimental data, this research employs actual aggregated information from 29 utilities offering optional TOU rates. By incorporating neo-classical demand analysis into an aggregated random coefficient logit model, I investigate the impact of both price and non-price tariff characteristics and non-tariff factors on customer choice behavior. The analysis indicates that customer pure tariff preference (which captures the

  15. Incorporating Experience Curves in Appliance Standards Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Garbesi, Karina; Chan, Peter; Greenblatt, Jeffery; Kantner, Colleen; Lekov, Alex; Meyers, Stephen; Rosenquist, Gregory; Buskirk, Robert Van; Yang, Hung-Chia; Desroches, Louis-Benoit

    2011-10-31

    The technical analyses in support of U.S. energy conservation standards for residential appliances and commercial equipment have typically assumed that manufacturing costs and retail prices remain constant during the projected 30-year analysis period. There is, however, considerable evidence that this assumption does not reflect real market prices. Costs and prices generally fall in relation to cumulative production, a phenomenon known as experience and modeled by a fairly robust empirical experience curve. Using price data from the Bureau of Labor Statistics, and shipment data obtained as part of the standards analysis process, we present U.S. experience curves for room air conditioners, clothes dryers, central air conditioners, furnaces, and refrigerators and freezers. These allow us to develop more representative appliance price projections than the assumption-based approach of constant prices. These experience curves were incorporated into recent energy conservation standards for these products. The impact on the national modeling can be significant, often increasing the net present value of potential standard levels in the analysis. In some cases a previously cost-negative potential standard level demonstrates a benefit when incorporating experience. These results imply that past energy conservation standards analyses may have undervalued the economic benefits of potential standard levels.

  16. Analysis on learning curves of end-use appliances for the establishment of price-sensitivity load model in competitive electricity market

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Sung Wook; Kim, Jung Hoon [Hongik University (Korea); Song, Kyung Bin [Keimyung University (Korea); Choi, Joon Young [Jeonju University (Korea)

    2001-07-01

    The change of the electricity charge from cost base to price base due to the introduction to the electricity market competition causes consumer to choose a variety of charge schemes and a portion of loads to be affected by this change. Besides, it is required the index that consolidate the price volatility experienced on the power exchange with gaming and strategic bidding by suppliers to increase profits. Therefore, in order to find a mathematical model of the sensitively-responding to-price loads, the price-sensitive load model is needed. And the development of state-of- the-art technologies affects the electricity price, so the diffusion of high-efficient end-uses and these price affect load patterns. This paper shows the analysis on learning curves algorithms which is used to investigate the correlation of the end-uses' price and load patterns. (author). 6 refs., 4 figs., 4 tabs.

  17. Estimating State-Specific Contributions to PM2.5- and O3-Related Health Burden from Residential Combustion and Electricity Generating Unit Emissions in the United States.

    Science.gov (United States)

    Penn, Stefani L; Arunachalam, Saravanan; Woody, Matthew; Heiger-Bernays, Wendy; Tripodis, Yorghos; Levy, Jonathan I

    2017-03-01

    Residential combustion (RC) and electricity generating unit (EGU) emissions adversely impact air quality and human health by increasing ambient concentrations of fine particulate matter (PM 2.5 ) and ozone (O 3 ). Studies to date have not isolated contributing emissions by state of origin (source-state), which is necessary for policy makers to determine efficient strategies to decrease health impacts. In this study, we aimed to estimate health impacts (premature mortalities) attributable to PM 2.5 and O 3 from RC and EGU emissions by precursor species, source sector, and source-state in the continental United States for 2005. We used the Community Multiscale Air Quality model employing the decoupled direct method to quantify changes in air quality and epidemiological evidence to determine concentration-response functions to calculate associated health impacts. We estimated 21,000 premature mortalities per year from EGU emissions, driven by sulfur dioxide emissions forming PM 2.5 . More than half of EGU health impacts are attributable to emissions from eight states with significant coal combustion and large downwind populations. We estimate 10,000 premature mortalities per year from RC emissions, driven by primary PM 2.5 emissions. States with large populations and significant residential wood combustion dominate RC health impacts. Annual mortality risk per thousand tons of precursor emissions (health damage functions) varied significantly across source-states for both source sectors and all precursor pollutants. Our findings reinforce the importance of pollutant-specific, location-specific, and source-specific models of health impacts in design of health-risk minimizing emissions control policies. Citation: Penn SL, Arunachalam S, Woody M, Heiger-Bernays W, Tripodis Y, Levy JI. 2017. Estimating state-specific contributions to PM 2.5 - and O 3 -related health burden from residential combustion and electricity generating unit emissions in the United States. Environ

  18. Documentation of Appliances & Interaction Devices

    DEFF Research Database (Denmark)

    2004-01-01

    The interaction devices and appliances explored in the WorkSPACE project, address spatial computing in the context of work. We have developed and explored a range of appliances and interaction devices. The scope has been to develop tools for support of collaboration by mixing digital and physical...

  19. Remote repair appliance

    International Nuclear Information System (INIS)

    Heumann, F.K.; Wilkinson, J.C.; Wooding, D.R.

    1997-01-01

    A remote appliance for supporting a tool for performing work at a work site on a substantially circular bore of a work piece and for providing video signals of the work site to a remote monitor comprises: a base plate having an inner face and an outer face; a plurality of rollers, wherein each roller is rotatably and adjustably attached to the inner face of the base plate and positioned to roll against the bore of the work piece when the base plate is positioned against the mouth of the bore such that the appliance may be rotated about the bore in a plane substantially parallel to the base plate; a tool holding means for supporting the tool, the tool holding means being adjustably attached to the outer face of the base plate such that the working end of the tool is positioned on the inner face side of the base plate; a camera for providing video signals of the work site to the remote monitor; and a camera holding means for supporting the camera on the inner face side of the base plate, the camera holding means being adjustably attached to the outer face of the base plate. In a preferred embodiment, roller guards are provided to protect the rollers from debris and a bore guard is provided to protect the bore from wear by the rollers and damage from debris. 5 figs

  20. Improvements in appliance holders

    International Nuclear Information System (INIS)

    Chapman, J.E.

    1977-01-01

    Reference is made to appliance holders for locating tools, instruments, etc. in operative relationship to workpieces and accessible through passageways of restricted transverse dimensions. The appliance holder described comprises an elongated external frame provided with transversely, outwardly expanding frictional gripping means in two longitudinally spaced sets and with a ring of spur teeth. An inner elongated frame is held within the external frame in two longitudinally spaced rotary bearings and carries a spur wheel which engages the ring of the spur teeth. A motor is arranged to rotate the spur wheel and hence the inner frame in relation to the external frame. A carriage is carried by the inner frame, longitudinally movable by a motor in relation thereto, and a further carriage is mounted on this first carriage. This second cariage is transversely movable in relation to the inner frame and is provided with a face plate for attachment of tools, instruments, etc. A motor is mounted on the first carriage for moving the second carriage. (U.K.)

  1. Fiscal 2000 project for development of international standards for supporting novel industries. Standardization for securement of interconnection between intelligent home electric appliances; 2000 nendo shinki sangyo shiengata kokusai hyojun kaihatsu jigyo. Johokadenkiki kan no sogo setsuzokusei kakuho no tameno hyojunka

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Research and development had been under way since fiscal 1998 for working out propositions relating to the international standardization of connection interface systems for digital AV (audio-visual) equipment. This report outlines the result of the project in its fiscal last year. The link working group (WG) actually built a transceiver at 5 mm pitch in its second trial, measured and evaluated its behavior under high-temperature and high-humidity circumstances, and acquired numerical data for interface specifications. The connection interface WG in its second trial fabricated a tiny optical connector for POF (plastic optical fiber) and evaluated its resistance to environment. As the result, sufficient resistance to environment was detected in the connector, and then a proposition was presented to IEC/TC86 that the connector be standardized as an optical connector for intelligent home electric appliances. The POF optimization WG performed an environment resistant test for POF, similar to those for transceivers and connectors, and then recognized that POF of the GI type was low in transmission loss and that it stably retained its wide-band feature. (NEDO)

  2. Modeling electric load and water consumption impacts from an integrated thermal energy and rainwater storage system for residential buildings in Texas

    International Nuclear Information System (INIS)

    Upshaw, Charles R.; Rhodes, Joshua D.; Webber, Michael E.

    2017-01-01

    Highlights: • Hydronic integrated rainwater thermal storage (ITHERST) system concept presented. • ITHERST system modeled to assess peak electric load shifting and water savings. • Case study shows 75% peak load reduction and 9% increase in energy consumption. • Potable rainwater collection could provide ∼50–90% of water used for case study. - Abstract: The United States’ built environment is a significant direct and indirect consumer of energy and water. In Texas, and other parts of the Southern and Western US, air conditioning loads, particularly from residential buildings, contribute significantly to the peak electricity load on the grid, straining transmission. In parallel, water resources in these regions are strained by growing populations and shrinking supplies. One potential method to address both of these issues is to develop integrated thermal energy and auxiliary water (e.g. rainwater, greywater, etc.) storage and management systems that reduce peak load and freshwater consumption. This analysis focuses on a proposed integrated thermal energy and rainwater storage (ITHERST) system that is incorporated into a residential air-source chiller/heat pump with hydronic distribution. This paper describes a step-wise hourly thermodynamic model of the thermal storage system to assess on-peak performance, and a daily volume-balance model of auxiliary water collection and consumption to assess water savings potential. While the model is generalized, this analysis uses a case study of a single family home in Austin, Texas to illustrate its capabilities. The results indicate this ITHERST system could reduce on-peak air conditioning electric power demand by over 75%, with increased overall electric energy consumption of approximately 7–9%, when optimally sized. Additionally, the modeled rainwater collection reduced municipal water consumption by approximately 53–89%, depending on the system size.

  3. Analysis of residential, industrial and commercial sector responses to potential electricity supply constraints in the 1990s

    Energy Technology Data Exchange (ETDEWEB)

    Fisher, Z.J.; Fang, J.M.; Lyke, A.J.; Krudener, J.R.

    1986-09-01

    There is considerable debate over the ability of electric generation capacity to meet the growing needs of the US economy in the 1990s. This study provides new perspective on that debate and examines the possibility of power outages resulting from electricity supply constraints. Previous studies have focused on electricity supply growth, demand growth, and on the linkages between electricity and economic growth. This study assumes the occurrence of electricity supply shortfalls in the 1990s and examines the steps that homeowners, businesses, manufacturers, and other electricity users might take in response to electricity outages.

  4. Transforce lingual appliances pre-adjusted invisible appliances simplify treatment.

    Science.gov (United States)

    Clark, William John

    2011-01-01

    Transforce lingual appliances are designed to be used in conjunction with conventional fixed appliances. Lingual arch development is normally followed by bonded fixed appliances to detail the occlusion. Alternatively Transforce appliance treatment is an efficient method of preparing complex malocclusions prior to a finishing stage with invisible appliances. This approach is ideal for adult treatment, using light continuous forces for arch development with appliances that are comfortable to wear. Sagittal and Transverse appliances are designed for arch development in a range of sizes for contracted arches. They can be used to treat all classes of malocclusion and are pre-adjusted fixed/removable devices for non-compliance treatment. Force modules with nickel titanium coil springs enclosed in a tube deliver a gentle, biocompatible continuous force with a long range of action. They are excellent for mixed dentition and ideal for adult arch development. There are multiple sizes for upper and lower arch development and a sizing chart may be placed over a study model for correct selection, eliminating the need for laboratory work.

  5. Assessment of Literature Related to Combustion Appliance Venting Systems

    Energy Technology Data Exchange (ETDEWEB)

    Rapp, Vi H. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Singer, Brett C. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Stratton, Chris [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Wray, Craig P. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-06-01

    In many residential building retrofit programs, air tightening to increase energy efficiency is constrained by concerns about related impacts on the safety of naturally vented combustion appliances. Tighter housing units more readily depressurize when exhaust equipment is operated, making combustion appliances more prone to backdraft or spillage. Several test methods purportedly assess the potential for depressurization-induced backdrafting and spillage, but these tests are not robustly reliable and repeatable predictors of venting performance, in part because they do not fully capture weather effects on venting performance. The purpose of this literature review is to investigate combustion safety diagnostics in existing codes, standards, and guidelines related to combustion appliances. This review summarizes existing combustion safety test methods, evaluations of these test methods, and also discusses research related to wind effects and the simulation of vent system performance. Current codes and standards related to combustion appliance installation provide little information on assessing backdrafting or spillage potential. A substantial amount of research has been conducted to assess combustion appliance backdrafting and spillage test methods, but primarily focuses on comparing short-term (stress) induced tests and monitoring results. Monitoring, typically performed over one week, indicated that combinations of environmental and house operation characteristics most conducive to combustion spillage were rare. Research, to an extent, has assessed existing combustion safety diagnostics for house depressurization, but the objectives of the diagnostics, both stress and monitoring, are not clearly defined. More research is also needed to quantify the frequency of test “failure” occurrence throughout the building stock and assess the statistical effects of weather (especially wind) on house depressurization and in turn on combustion appliance venting

  6. Turning the appliance market around towards A++

    Energy Technology Data Exchange (ETDEWEB)

    Noergaard, Joergen S.; Guldbrandsen, Tom [Dept. of Civil Engineering, Technical Univ. of Denmark (Denmark); Brange, Birgitte; Karbo, Peter [Elsparefonden (Denmark)

    2007-07-01

    In an effort to exploit better the labelling schemes for appliances the Danish Electricity Saving Trust has run some campaigns on cold appliances. In 1999 focus was on getting people to choose A-rated models, the 2004 campaign focussed on A+, and in 2005 on A++. These campaigns and their results are described in the paper and some conclusions are drawn.The campaigns have consisted of various elements, namely 1) a general information about the campaigns, 2) a subsidy offered temporarily during some months to people buying the A, A+ and A++ models, 3) a website where people can easily find the most energy efficient model within their specification, and 4) in the website are also listed the shops, where consumers can get the appliances at lowest prices. The latter was the most innovative and maybe also the most effective measure in the package.Results showed up as a permanent U-turn of the market in the course of a few years. Where models C, D, E earlier dominated the market, the A, A+ and A++, came to dominate as the standard models in stock. Consequently, their prices dropped significantly. The theory of a rational market behavior is based on some assumptions, one being that full information is available to all actors. The website identifying to the consumers the shops with the lowest priced efficient models was a step in that direction, and the result did not fail to turn up.

  7. Optimizing Energy Savings from Direct-DC in U.S. Residential Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Garbesi, Karina; Vossos, Vagelis; Sanstad, Alan; Burch, Gabriel

    2011-10-13

    An increasing number of energy efficient appliances operate on direct current (DC) internally, offering the potential to use DC from renewable energy systems directly and avoiding the losses inherent in converting power to alternating current (AC) and back. This paper investigates that potential for net-metered residences with on-site photovoltaics (PV) by modeling the net power draw of the ‘direct-DC house’ with respect to today’s typical configuration, assuming identical DC-internal loads. Power draws were modeled for houses in 14 U.S. cities, using hourly, simulated PV-system output and residential loads. The latter were adjusted to reflect a 33% load reduction, representative of the most efficient DC-internal technology, based on an analysis of 32 electricity end-uses. The model tested the effect of climate, electric vehicle (EV) loads, electricity storage, and load shifting on electricity savings; a sensitivity analysis was conducted to determine how future changes in the efficiencies of power system components might affect savings potential. Based on this work, we estimate that net-metered PV residences could save 5% of their total electricity load for houses without storage and 14% for houses with storage. Based on residential PV penetration projections for year 2035 obtained from the National Energy Modeling System (2.7% for the reference case and 11.2% for the extended policy case), direct-DC could save the nation 10 trillion Btu (without storage) or 40 trillion Btu (with storage). Shifting the cooling load by two hours earlier in the day (pre-cooling) has negligible benefits for energy savings. Direct-DC provides no energy savings benefits for EV charging, to the extent that charging occurs at night. However, if charging occurred during the day, for example with employees charging while at work, the benefits would be large. Direct-DC energy savings are sensitive to power system and appliance conversion efficiencies but are not significantly

  8. Wood-burning appliances and indoor air quality

    Energy Technology Data Exchange (ETDEWEB)

    Levesque, Benoit; Allaire, Sylvain; Gauvin, Denis; Gingras, Suzanne; Rhainds, Marc; Prud' Homme, Henri; Duchesne, Jean-Francois [CHUQ-Centre de Recherche du CHUL, Unite de Recherche en Sante Publique, 2400, d' Estimauville, Beauport, G1E 7G9 Quebec (Canada); Koutrakis, Petros [Harvard School of Public Health, 677 Huntington Avenue, Boston, MA 02115 (United States)

    2001-12-17

    Wood heating represents an interesting economic alternative to electrical or heating oil and gas systems. However, many people are concerned about poor indoor air quality in homes equipped with wood-burning appliances. We conducted a study in the Quebec City region (Canada) to verify the extent of indoor air contamination, and to examine the frequency of respiratory symptoms and illnesses among occupants of wood-heated homes. One child attending primary school (median=8 years old; range=5-14 years old) and an adult (median=37 years old; range=23-52 years old) were recruited in each eligible house. Eligible houses were without known sources of combustion products (smokers, attached garage, oil or gas furnace, gas stove, etc.) except for wood-burning appliance. Out of the 89 houses included in the study, 59 had wood-burning appliances. Formaldehyde, nitrogen dioxide, respirable particles (PM10) and carbon monoxide were measured in a sub-set of 49 houses (41 with a wood-burning appliance and 8 without). The frequency of respiratory symptoms and diseases among participants were documented using a daily symptom diary. Concentrations of contaminants were low in most houses, both with or without a wood-burning appliance. Globally, there was no consistent relationship between the presence of a wood-burning appliance and respiratory morbidity in residents. Nevertheless, residents who mentioned being exposed to fumes emitted by such an appliance reported more respiratory illnesses and symptoms. The presence of animals or molds, and keeping windows closed most of the time in winter were other factors associated with respiratory problems. We conclude that wood burning appears to be a respiratory health risk for occupants if the appliance is not maintained and used properly.

  9. Metal release from simulated fixed orthodontic appliances.

    Science.gov (United States)

    Hwang, C J; Shin, J S; Cha, J Y

    2001-10-01

    Most orthodontic appliances and archwires are stainless steel or nickel-titanium (NiTi) alloys that can release metal ions, with saliva as the medium. To measure metal released from the fixed orthodontic appliances currently in use, we fabricated simulated fixed orthodontic appliances that corresponded to half of the maxillary arch and soaked them in 50 mL of artificial saliva (pH 6.75 +/- 0.15, 37 degrees C) for 3 months. We used brackets, tubes, and bands made by Tomy (Tokyo, Japan). Four groups were established according to the appliance manufacturer and the type of metal in the .016 x .022-in archwires. Groups A and B were stainless steel archwires from Ormco (Glendora, Calif) and Dentaurum (Ispringen, Germany), respectively, and groups C and D were both NiTi archwires with Ormco's copper NiTi and Tomy's Bioforce sentalloy, respectively. Stainless steel archwires were heat treated in an electric furnace at 500 degrees C for 1 minute and quenched in water. We measured the amount of metal released from each group by immersion time. Our conclusions were as follows: (1) there was no increase in the amount of chromium released after 4 weeks in group A, 2 weeks in group B, 3 weeks in group C, and 8 weeks in group D; (2) there was no increase in the amount of nickel released after 2 weeks in group A, 3 days in group B, 7 days in group C, and 3 weeks in group D; and (3) there was no increase in the amount of iron released after 2 weeks in group A, 3 days in group B, and 1 day in groups C and D. In our 3-month-long investigation, we saw a decrease in metal released as immersion time increased.

  10. An orthodontic oral appliance.

    Science.gov (United States)

    Marklund, Marie; Legrell, Per Erik

    2010-11-01

    This pilot study was performed to test the hypothesis that an orthodontic oral appliance (OA) that is designed to work against the backwardly directed forces on the upper incisors may counteract the reduction in overjet from these devices. Thirty patients with normal bites, good oral health, and milder sleep apnea were randomized to treatment with either OAs or orthodontic OAs. Bite changes were evaluated on plaster casts and radiographs and by questionnaires after a mean of 2.4 years in 19 frequent users. Four of nine patients in the orthodontic OA group increased their overjet by > or =0.4 mm, while none of the 10 patients in the OA group experienced that effect. Only the orthodontic OA increases the overjet; this design may therefore be beneficial to patients at risk of negative effects on their bite during OA treatment.

  11. Optimal behavior of responsive residential demand considering hybrid phase change materials

    International Nuclear Information System (INIS)

    Shafie-khah, M.; Kheradmand, M.; Javadi, S.; Azenha, M.; Aguiar, J.L.B. de; Castro-Gomes, J.; Siano, P.; Catalão, J.P.S.

    2016-01-01

    Highlights: • An operational model of HEM system incorporating with a hybrid PCM is proposed in this paper. • Incorporation of hybrid PCM mortar had a complementary effect on the proposed HEM system. • The proposed model ensures the technical and economic limits of batteries and electrical appliances. • The customer’s electricity cost can be reduced up to 48% by utilizing the proposed model. - Abstract: Due to communication and technology developments, residential consumers are enabled to participate in Demand Response Programs (DRPs), control their consumption and decrease their cost by using Household Energy Management (HEM) systems. On the other hand, capability of energy storage systems to improve the energy efficiency causes that employing Phase Change Materials (PCM) as thermal storage systems to be widely addressed in the building applications. In this paper, an operational model of HEM system considering the incorporation of more than one type of PCM in plastering mortars (hybrid PCM) is proposed not only to minimize the customer’s cost in different DRPs but also to guaranty the habitants’ satisfaction. Moreover, the proposed model ensures the technical and economic limits of batteries and electrical appliances. Different case studies indicate that implementation of hybrid PCM in the buildings can meaningfully affect the operational pattern of HEM systems in different DRPs. The results reveal that the customer’s electricity cost can be reduced up to 48% by utilizing the proposed model.

  12. Electrical network capacity support from demand side response: Techno-economic assessment of potential business cases for small commercial and residential end-users

    International Nuclear Information System (INIS)

    Martínez Ceseña, Eduardo A.; Good, Nicholas; Mancarella, Pierluigi

    2015-01-01

    Demand Side Response (DSR) is recognised for its potential to bring economic benefits to various electricity sector actors, such as energy retailers, Transmission System Operators (TSOs) and Distribution Network Operators (DNOs). However, most DSR is provided by large industrial and commercial consumers, and little research has been directed to the quantification of the value that small (below 100 kW) commercial and residential end-users could accrue by providing DSR services. In particular, suitable models and studies are needed to quantify potential business cases for DSR from small commercial and residential end-users. Such models and studies should consider the technical and physical characteristics of the power system and demand resources, together with the economic conditions of the power market. In addition, the majority of research focuses on provision of energy arbitrage or ancillary services, with very little attention to DSR services for network capacity support. Accordingly, this paper presents comprehensive techno-economic methodologies for the quantification of three capacity-based business cases for DSR from small commercial and residential end-users. Case study results applied to a UK context indicate that, if the appropriate regulatory framework is put in place, services for capacity support to both DNOs and TSOs can result into potentially attractive business cases for DSR from small end-users with minimum impact on their comfort level. -- Highlights: •We present three business cases for DSR from domestic and commercial end-users. •A comprehensive techno-economic methodology is proposed for the quantification of each DSR business cases. •The regulatory implications associated with each business case are discussed

  13. GREEN RETROFITTING RESIDENTIAL BUILDINGS

    Science.gov (United States)

    When compared with the rest of the world, the United States consumes a disproportionately large amount of energy and is a major source of greenhouse gases from fossil fuel combustion. As much as two thirds of U.S. electricity production is consumed by residential and commerci...

  14. Technical and Economic Evaluation of «Electric House» Project: Investigation of Possibility to Use Electric Power as Single Energy Carrier in Residential Buildings

    OpenAIRE

    M. M. Oleshkevich; Y. V. Makosko

    2011-01-01

    The paper considers special features of the «Electric House» project where the building is provided with electric power, cold water and sewerage system. The «Electric House» is characterized by ecological cleanness, high reliability in power supply and low capital costs. While running the «Electric House» an annual expenditure of equivalent fuel is increased due to low efficiency of electric power generation at power plants. The profit obtained due to «Electric House» construction is depleted...

  15. The electric energy consumption in the city of Sao Paulo - Brazil: the residential sector in the eighties; O consumo de energia eletrica na cidade de Sao Paulo: o setor residencial nos anos oitenta

    Energy Technology Data Exchange (ETDEWEB)

    Borelli, A.B.; Sellito, Y.M.; Moreira, J.G.S. [Sao Paulo Univ., SP (Brazil). Inst. de Eletrotecnica e Energia

    1994-07-01

    This work analyses the evolution of the energy consumption in the residential sector of the city of Sao Paulo in the years of 19980, 1985 and 1990, and relates electric power cost participation in the family monthly stratified budget. Also, the price x consumption elasticity verified in the mentioned period is analysed.

  16. A Study on Efficient Energy Use for Household Appliances in Malawi

    African Journals Online (AJOL)

    Keywords: Efficient , energy use, household appliances, power consumption. ... Although the hydro-electric power transmission lines extend the entire length of ..... R. Karri and P. Mishra, “Minimizing Energy Consumption of Secure Wireless ...

  17. Energy usage and technical potential for energy saving measures in the Swedish residential building stock

    International Nuclear Information System (INIS)

    Mata, Érika; Sasic Kalagasidis, Angela; Johnsson, Filip

    2013-01-01

    This paper provides an analysis of the current energy usage (net energy and final energy by fuels) and associated carbon dioxide (CO 2 ) emissions of the Swedish residential building stock, which includes single-family dwellings and multi-family dwellings. Twelve energy saving measures (ESMs) are assessed using a bottom–up modeling methodology, in which the Swedish residential stock is represented by a sample of 1400 buildings (based on data from the year 2005). Application of the ESMs studied gives a maximum technical reduction potential in energy demand of 53%, corresponding to a 63% reduction in CO 2 emissions. Although application of the investigated ESMs would reduce CO 2 emissions, the measures that reduce electricity consumption for lighting and appliances (LA) will increase CO 2 emissions, since the saved electricity production is less CO 2 -intensive than the fuel mix used for the increased space heating required to make up for the loss in indirect heating obtained from LA. - Highlights: ► Analysis of year 2005energy use and CO2 emissions of Swedish residential buildings. ► Includes all single-family dwellings and multi-family dwellings. ► Bottom–up modeling of building stock represented by 1400 buildings. ► Technical effects of 12 energy saving measures are assessed. ► Energy demand can be reduced by53% and associated CO 2 emissions by 63%

  18. Major models and data sources for residential and commercial sector energy conservation analysis. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1980-09-01

    Major models and data sources are reviewed that can be used for energy-conservation analysis in the residential and commercial sectors to provide an introduction to the information that can or is available to DOE in order to further its efforts in analyzing and quantifying their policy and program requirements. Models and data sources examined in the residential sector are: ORNL Residential Energy Model; BECOM; NEPOOL; MATH/CHRDS; NIECS; Energy Consumption Data Base: Household Sector; Patterns of Energy Use by Electrical Appliances Data Base; Annual Housing Survey; 1970 Census of Housing; AIA Research Corporation Data Base; RECS; Solar Market Development Model; and ORNL Buildings Energy Use Data Book. Models and data sources examined in the commercial sector are: ORNL Commercial Sector Model of Energy Demand; BECOM; NEPOOL; Energy Consumption Data Base: Commercial Sector; F.W. Dodge Data Base; NFIB Energy Report for Small Businesses; ADL Commercial Sector Energy Use Data Base; AIA Research Corporation Data Base; Nonresidential Buildings Surveys of Energy Consumption; General Electric Co: Commercial Sector Data Base; The BOMA Commercial Sector Data Base; The Tishman-Syska and Hennessy Data Base; The NEMA Commercial Sector Data Base; ORNL Buildings Energy Use Data Book; and Solar Market Development Model. Purpose; basis for model structure; policy variables and parameters; level of regional, sectoral, and fuels detail; outputs; input requirements; sources of data; computer accessibility and requirements; and a bibliography are provided for each model and data source.

  19. Instruments. Climate protection of reduction of no-load losses in electric appliances and equipment; Klimaschutz durch Minderung von Leerlaufverlusten bei Elektrogeraeten. Instrumente

    Energy Technology Data Exchange (ETDEWEB)

    Rath, U.; Hellmann, R. [Ingenieurbuero fuer Energieberatung, Haustechnik und Oekologische Konzepte GbR (eboek), Tuebingen (Germany); Moehring-Hueser, W.; Wortmann, K.; Bregas, J. [Energiestiftung Schleswig-Holstein, Kiel (Germany); Mordziol, C. [Umweltbundesamt, Berlin (Germany)

    1999-12-01

    Two studies on the subject of 'Climate Protection through Reduction of No-load Losses in Electric Applicances and Equipment' have been performed on behalf of the German Federal Ministry for the Environment, Nature Conservation and Nuclear Safety and the German Federal Environmental Agency. The first study, carried out by the Tuebingen-based engineering bureau eboek, has been published in the Federal Environmental Agency's TEXTE series (Texte 45/97, 2{sup nd} edition, 1998). It was the starting point for a multitude of activities among them two information campaigns carried out in 1998 and 1999 that were funded by the Federal Ministry for the Environment and the German Section of the Friends of the Earth (BUND). The study also served as a basis for decisions taken by the German Bundestag and the Bundesrat (Council of Constituent States). The second study on the subject was carried out by the engineering bureau eboek and Energiestiftung Schleswig-Holstein. Building on the results obtained in the first study, it presents estimates of relevant data for the European Union and examines various approaches for possible measures to reduce no-load losses as to their suitability. The studies impressively show that effective climate protection can be achieved in all relevant sectors, and in many cases even save costs. The results are detailed below. (orig.) [German] Im Auftrag des Bundesministeriums fuer Umwelt, Naturschutz und Reaktorsicherheit sowie des Umweltbundesamtes wurden zwei Studien zum Thema: 'Klimaschutz durch Minderung von Leerlaufverlusten bei Elektrogeraeten' durchgefuehrt: Die erste, vom Ingenieurbuero fuer Energieberatung, Haustechnik und oekologische Konzepte (eboek), Tuebingen, earbeitete Studie wurde in der Reihe TEXTE des UBA veroeffentlicht (Texte 45/97, 2. Auflage 1998). Sie bildete den Ausgangspunkt fuer eine Vielzahl von Aktivitaeten, unter anderem zwei vom Bundesumweltministerium finanzierte und vom Bund fuer Umwelt und

  20. Instruments. Climate protection of reduction of no-load losses in electric appliances and equipment; Klimaschutz durch Minderung von Leerlaufverlusten bei Elektrogeraeten. Instrumente

    Energy Technology Data Exchange (ETDEWEB)

    Rath, U; Hellmann, R [Ingenieurbuero fuer Energieberatung, Haustechnik und Oekologische Konzepte GbR (eboek), Tuebingen (Germany); Moehring-Hueser, W; Wortmann, K; Bregas, J [Energiestiftung Schleswig-Holstein, Kiel (Germany); Mordziol, C [Umweltbundesamt, Berlin (Germany)

    1999-12-01

    Two studies on the subject of 'Climate Protection through Reduction of No-load Losses in Electric Applicances and Equipment' have been performed on behalf of the German Federal Ministry for the Environment, Nature Conservation and Nuclear Safety and the German Federal Environmental Agency. The first study, carried out by the Tuebingen-based engineering bureau eboek, has been published in the Federal Environmental Agency's TEXTE series (Texte 45/97, 2{sup nd} edition, 1998). It was the starting point for a multitude of activities among them two information campaigns carried out in 1998 and 1999 that were funded by the Federal Ministry for the Environment and the German Section of the Friends of the Earth (BUND). The study also served as a basis for decisions taken by the German Bundestag and the Bundesrat (Council of Constituent States). The second study on the subject was carried out by the engineering bureau eboek and Energiestiftung Schleswig-Holstein. Building on the results obtained in the first study, it presents estimates of relevant data for the European Union and examines various approaches for possible measures to reduce no-load losses as to their suitability. The studies impressively show that effective climate protection can be achieved in all relevant sectors, and in many cases even save costs. The results are detailed below. (orig.) [German] Im Auftrag des Bundesministeriums fuer Umwelt, Naturschutz und Reaktorsicherheit sowie des Umweltbundesamtes wurden zwei Studien zum Thema: 'Klimaschutz durch Minderung von Leerlaufverlusten bei Elektrogeraeten' durchgefuehrt: Die erste, vom Ingenieurbuero fuer Energieberatung, Haustechnik und oekologische Konzepte (eboek), Tuebingen, earbeitete Studie wurde in der Reihe TEXTE des UBA veroeffentlicht (Texte 45/97, 2. Auflage 1998). Sie bildete den Ausgangspunkt fuer eine Vielzahl von Aktivitaeten, unter anderem zwei vom Bundesumweltministerium finanzierte und vom Bund fuer Umwelt und Naturschutz (BUND) 1998 und

  1. Alternative test method to assess the energy performance of frost-free refrigerating appliances

    International Nuclear Information System (INIS)

    Hermes, Christian J.L.; Melo, Cláudio; Knabben, Fernando T.

    2013-01-01

    This paper outlines an alternative test method to evaluate the energy consumption of frost-free refrigerators and freezers for residential applications. While the standardized methods require the refrigerating appliance to be kept running according to its onboard control system, which usually drives the refrigerator through an on–off cycling pattern, the proposed approach assesses the refrigerator energy performance in the steady-state regime, being therefore much faster and more reliable. In this procedure, the cooling capacity is matched to the cooling loads by PID-controlled electrical heaters installed within the refrigerated compartments, so that the compartment temperatures are kept at the desired standardized levels. Comparisons between the experimental results obtained using the steady-state energy test and the standardized procedures showed that the former follows closely the trends observed for the latter. - Highlights: ► An alternative test method to assess the energy consumption of refrigerators is proposed. ► PID-controlled electrical heaters were installed within the compartments. ► Steady-state and ISO energy tests were performed and compared. ► Both proposed and standardized test procedures showed similar trends.

  2. Residential consumer behavior during and after an energy crisis

    Energy Technology Data Exchange (ETDEWEB)

    Aragao Neto, Raymundo [International Institute for Energy Conservation, Rio de Janeiro, RJ (Brazil)]. E-mail: raragao@iiec.org; Javaroni, Mario Cesar [ECOLUZ Consultores Associados, Rio de Janeiro, RJ (Brazil)]. E-mail: javaroni@ecoluz.com.br

    2004-07-01

    Brazil faced a severe energy crisis during 2001 and 2002 that reflected in all sectors including residential, and obliged to reduce in 20 per cent consumption, considering 2000 basis. New products were largely used, and domestic customs changed. This paper evaluates how residential behaviour has changed during the crisis period, and one year later what initiatives (habits, appliances) remained, considering a survey with 240 consumers. (author)

  3. Electronic Control System Of Home Appliances Using Speech Command Words

    Directory of Open Access Journals (Sweden)

    Aye Min Soe

    2015-06-01

    Full Text Available Abstract The main idea of this paper is to develop a speech recognition system. By using this system smart home appliances are controlled by spoken words. The spoken words chosen for recognition are Fan On Fan Off Light On Light Off TV On and TV Off. The input of the system takes speech signals to control home appliances. The proposed system has two main parts speech recognition and smart home appliances electronic control system. Speech recognition is implemented in MATLAB environment. In this process it contains two main modules feature extraction and feature matching. Mel Frequency Cepstral Coefficients MFCC is used for feature extraction. Vector Quantization VQ approach using clustering algorithm is applied for feature matching. In electrical home appliances control system RF module is used to carry command signal from PC to microcontroller wirelessly. Microcontroller is connected to driver circuit for relay and motor. The input commands are recognized very well. The system is a good performance to control home appliances by spoken words.

  4. Emissions from wood domestic heating appliances

    International Nuclear Information System (INIS)

    Collet, S.

    2009-01-01

    Much research has been carried out to study emissions from wood domestic heating appliances. This work reviews the available emission factors about pollutants produced in different types of wood domestic heating appliances. The main sources of pollutants are older stoves that in most cases are used as an additional heating appliance. These stoves causes higher emissions than modern appliances. Then, substitution of an old type wood appliance with a modern appliance or boiler or a pellet boilers, would reduce considerably emissions in this sector. The efficiency of this measure is estimated for each pollutant. (author)

  5. Compliance with removable orthodontic appliances.

    Science.gov (United States)

    Shah, Nirmal

    2017-12-22

    Data sourcesMedline via OVID, PubMed, Cochrane Central Register of Controlled Trials, Web of Science Core Collection, LILACS and BBO databases. Unpublished clinical trials accessed using ClinicalTrials.gov, National Research Register, ProQuest Dissertation and Thesis database.Study selectionTwo authors searched studies from inception until May 2016 without language restrictions. Quantitative and qualitative studies incorporating objective data on compliance with removable appliances, barriers to appliance wear compliance, and interventions to improve compliance were included.Data extraction and synthesisQuality of research was assessed using the Cochrane Collaboration's risk of bias tool, the risk of bias in non-randomised studies of interventions (ROBINS-I), and the mixed methods appraisal tool. Statistical heterogeneity was investigated by examining a graphic display of the estimated compliance levels in conjunction with 95% confidence intervals and quantified using the I-squared statistic. A weighted estimate of objective compliance levels for different appliances in relation to stipulated wear and self-reported levels was also calculated. Risk of publication bias was assessed using funnel plots. Meta-regression was undertaken to assess the relative effects of appliance type on compliance levels.ResultsTwenty-four studies met the inclusion criteria. Of these, 11 were included in the quantitative synthesis. The mean duration of objectively measured wear was considerably lower than stipulated wear time amongst all appliances. Headgear had the greatest discrepancy (5.81 hours, 95% confidence interval, 4.98, 6.64). Self-reported wear time was consistently higher than objectively measured wear time amongst all appliances. Headgear had the greatest discrepancy (5.02 hours, 95% confidence interval, 3.64, 6.40). Two studies found an increase in compliance with headgear and Hawley retainers when patients were aware of monitoring. Five studies found younger age groups to

  6. Projected electricity savings from implementing minimum energy efficiency standard for household refrigerators in Malaysia

    International Nuclear Information System (INIS)

    Mahlia, T.M.I.; Masjuki, H.H.; Saidur, R.; Choudhury, I.A.; NoorLeha, A.R.

    2003-01-01

    The Malaysian economy has grown rapidly in the last two decades. This growth has increased the ownership of household electrical appliances, especially refrigerator-freezers. Almost every house in Malaysia owns a refrigerator-freezer. The Malaysia Energy Center considered implementing a minimum energy efficiency standard for household refrigerator-freezers sometime in the coming year. This paper attempts to predict the amount of energy savings in the residential sector by implementing a minimum energy efficiency standard for household refrigerator-freezers. The calculations are based on the growth of refrigerator-freezer ownership data in Malaysian households. By implementing the programs in 2004, about 8722 GWh will be saved in the year 2013. Therefore, efficiency improvement of this appliance will provide a significant impact in future electricity consumption in Malaysia

  7. Residential Care

    Science.gov (United States)

    ... Kids For Teens For Parents & Teachers Resolving Family Conflicts The Holidays and Alzheimer's Glossary Virtual Library Online ... longer an option Costs Choosing a care setting Types of residential care A good long-term care ...

  8. The Use of Biomass for Electricity Generation: A Scoping Review of Health Effects on Humans in Residential and Occupational Settings

    Directory of Open Access Journals (Sweden)

    Alice Freiberg

    2018-02-01

    Full Text Available The utilization of biomass for power generation has become more prevalent globally. To survey the status of evidence concerning resulting health impacts and to depict potential research needs, a scoping-review was conducted. Biomass life cycle phases of interest were the conversion and combustion phases. Studies from occupational and residential settings were considered. The scoping review was conducted systematically, comprising an extensive literature search, a guided screening process, in-duplicate data extraction, and critical appraisal. Two reviewers executed most review steps. Nine articles of relevance were identified. In occupational settings of biomass plants, exposure to endotoxins and fungi might be associated with respiratory disorders. An accidental leakage of hydrogen sulfide in biogas plants may lead to fatalities or severe health impacts. Living near biomass power plants (and the accompanied odorous air pollution may result in an increased risk for several symptoms and odor annoyance, mediated by perception about air pollution or an evaluation of a resulting health risk. The methodological quality of included studies varied a lot. Overall, the body of evidence on the topic is sparse and future high-quality research is strongly recommended.

  9. The Use of Biomass for Electricity Generation: A Scoping Review of Health Effects on Humans in Residential and Occupational Settings.

    Science.gov (United States)

    Freiberg, Alice; Scharfe, Julia; Murta, Vanise C; Seidler, Andreas

    2018-02-16

    The utilization of biomass for power generation has become more prevalent globally. To survey the status of evidence concerning resulting health impacts and to depict potential research needs, a scoping-review was conducted. Biomass life cycle phases of interest were the conversion and combustion phases. Studies from occupational and residential settings were considered. The scoping review was conducted systematically, comprising an extensive literature search, a guided screening process, in-duplicate data extraction, and critical appraisal. Two reviewers executed most review steps. Nine articles of relevance were identified. In occupational settings of biomass plants, exposure to endotoxins and fungi might be associated with respiratory disorders. An accidental leakage of hydrogen sulfide in biogas plants may lead to fatalities or severe health impacts. Living near biomass power plants (and the accompanied odorous air pollution) may result in an increased risk for several symptoms and odor annoyance, mediated by perception about air pollution or an evaluation of a resulting health risk. The methodological quality of included studies varied a lot. Overall, the body of evidence on the topic is sparse and future high-quality research is strongly recommended.

  10. Look-Ahead Energy Management of a Grid-Connected Residential PV System with Energy Storage under Time-Based Rate Programs

    Directory of Open Access Journals (Sweden)

    Kyeon Hur

    2012-04-01

    Full Text Available This paper presents look-ahead energy management system for a grid-connected residential photovoltaic (PV system with battery under critical peak pricing for electricity, enabling effective and proactive participation of consumers in the Smart Grid’s demand response. In the proposed system, the PV is the primary energy source with the battery for storing (or retrieving excessive (or stored energy to pursue the lowest possible electricity bill but it is grid-tied to secure electric power delivery. Premise energy management scheme with an accurate yet practical load forecasting capability based on a Kalman filter is designed to increase the predictability in controlling the power flows among these power system components and the controllable electric appliances in the premise. The case studies with various operating scenarios demonstrate the validity of the proposed system and significant cost savings through operating the energy management scheme.

  11. Lifecycle cost and CO2 emissions of residential heat and electricity prosumers in Finland and the Netherlands

    NARCIS (Netherlands)

    Manrique Delgado, B.; Kotireddy, R.R.; Cao, S.; Hasan, A.; Hoes, P.-J.; Hensen, J.L.M.; Sirén, K.

    2018-01-01

    The complexity of finding solutions to reach energy sustainability in the built environment poses a significant challenge. Therefore, there is interest in adequate management of the generation, conversion, storage, use and exchange of heat and electricity. The novelty of this study exists in

  12. Climate, weather, socio-economic and electricity usage data for the residential and commercial sectors in FL, U.S

    Directory of Open Access Journals (Sweden)

    Sayanti Mukherjee

    2017-08-01

    Full Text Available This paper presents the data that is used in the article entitled “Climate sensitivity of end-use electricity consumption in the built environment: An application to the state of Florida, United States” (Mukhopadhyay and Nateghi, 2017 [1]. The data described in this paper pertains to the state of Florida (during the period of January 1990 to November 2015. It can be classified into four categories of (i state-level electricity consumption data; (ii climate data; (iii weather data; and (iv socio-economic data. While, electricity consumption data and climate data are obtained at monthly scale directly from the source, the weather data was initially obtained at daily-level, and then aggregated to monthly level for the purpose of analysis. The time scale of socio-economic data varies from monthly-level to yearly-level. This dataset can be used to analyze the influence of climate and weather on the electricity demand as described in Mukhopadhyay and Nateghi (2017 [1].

  13. Energy efficient appliance choice under the EU labeling scheme

    Energy Technology Data Exchange (ETDEWEB)

    Mills, Bradford F.; Schleich, Joachim [Fraunhofer-Institut fuer System- und Innovationsforschung (ISI), Karlsruhe (Germany)

    2010-02-15

    This paper extends the existing empirical literature on consumers' choices when exposed to energy labeling schemes by allowing choices to depend on household socio-economic characteristics, technology-related factors, behavioral and motivational factors, and country conditions in a multi-country analysis. To account for a possible knowledge-based selection bias, the econometric model distinguishes label class knowledge from the energy class choice decision. As a general finding, most covariates show stronger relationships with knowledge of labeling class than with the choice of energy efficiency class. Four factors show particularly strong and expected influences on label class awareness. First, general awareness of household energy use and energy saving technologies spills over into awareness of the energy class of specific appliances. Second, socioeconomic characteristics mater, as education increases label class awareness and older age reduces awareness. Third, economic incentives matter, as stated economic importance of energy saving and higher country electricity prices both generate greater label awareness. By contrast, stated concerns about global warming do not appear to have a broad impact on awareness. Fourth, effective country implementation of the labeling scheme raises label awareness. More surprisingly, most factors that promote awareness of appliance energy classes have a limited influence on actual appliance energy class choice. Efficient energy behavior in the household is not strongly linked to appliance energy class choice. Socio-economic characteristics also have limited influence. This finding is inline with other studies that find that household socio-economic characteristics have relatively weak associations with the adoption of energy efficient technologies (Mills and Schleich 2010, Brohmann et al. 2009). In fact, with education it is vocational degrees rather than university degrees that are positively associated with the propensity to

  14. Resource and revenue potential of California residential load participation in ancillary services

    International Nuclear Information System (INIS)

    Mathieu, Johanna L.; Dyson, Mark E.H.; Callaway, Duncan S.

    2015-01-01

    Increasing penetrations of intermittent renewable energy resources will require additional power system services. California recently adopted an energy storage mandate to support its renewable portfolio standard, which requires 33% of delivered energy from renewables by 2020. The objective of this paper is to estimate the amount of energy storage that could be provided by residential thermostatically controlled loads, such as refrigerators and air conditioners, and the amount of revenue that could be earned by loads participating in ancillary services markets. We model load aggregations as virtual energy storage, and use simple dynamical system models and publicly available data to generate our resource and revenue estimates. We find that the resource potential is large: 10–40 GW/8–12 GWh, which is significantly more than that required by the mandate. We also find that regulation and spinning/non-spinning reserve revenues vary significantly depending upon type of load and, for heat pumps and air conditioners, climate zone. For example, mean regulation revenues for refrigerators are $11/year, for electric water heaters are $24/year, for air conditioners are $0-32/year, and for heat pumps are $22–56/year. Both consumer choices, such as appliance settings, and policy, such as the design of ancillary service compensation and appliance standards, could increase revenue potentials. - Highlights: • California's energy storage mandate requires 1.325 GW of energy storage by 2020. • Residential loads such as refrigerators have thermal energy storage. • California's residential loads could provide 10-40 GW/8-12 GWh of storage. • Loads participating in ancillary services markets could earn up to $56/load/year. • Consumer choices and policy mechanisms could increase revenue potentials

  15. Assessing the benefits of residential demand response in a real time distribution energy market

    International Nuclear Information System (INIS)

    Siano, Pierluigi; Sarno, Debora

    2016-01-01

    Highlights: • A new probabilistic methodology, integrating DR in a distribution energy market is proposed. • The method can alleviate distribution network congestions. • This method based on D-LMPs allows cost savings for end-user customers. • Innovative thermal and shiftable loads Real Time control algorithms are also presented. - Abstract: In the field of electricity distribution networks and with the advent of smart grids and microgrids, the use of Distribution Locational Marginal Price (D-LMPs) in a Real Time (RT) distribution market managed by a Distribution System Operator (DSO) is discussed in presence of empowered residential end-users that are able to bid for energy by a demand aggregator while following Demand Response (DR) initiatives. Each customer is provided by a transactive controller, which reads the locational market signals and answers with a bid taking into account the user preferences about some appliances involved in DR activities and controlled by smart plugs-in. In particular, Heating Ventilation and Air Conditioning (HVAC) appliances and shiftable loads are controlled so that their consumption profile can be modified according to the price of energy. In order to assess the effectiveness of the proposed method in terms of energy and cost saving, an innovative probabilistic methodology for evaluating the impact of residential DR choices considering uncertainties related to load demand, user preferences, environmental conditions, house thermal behavior and wholesale market trends has been proposed. The uncertainties related to the stochastic variations of the variables involved are modeled by using the Monte Carlo Simulation (MCS) method. The combination of MCS and RT distribution market simulation based on D-LMPs are used to assess the operation and impact of the DR method over one month. Simulations results on an 84-buses distribution network confirmed that the proposed method allows saving costs for residential end-users and making

  16. DC Home Appliances for DC Distribution System

    Directory of Open Access Journals (Sweden)

    MUHAMMAD KAMRAN

    2017-10-01

    Full Text Available This paper strengthens the idea of DC distribution system for DC microgrid consisting of a building of 50 apartments. Since the war of currents AC system has been dominant because of the paucity of research in the protection of the DC system. Now with the advance research in power electronics material and components, generation of electricity is inherently DC as by solar PV, fuel cell and thermoelectric generator that eliminates the rectification process. Transformers are replaced by the power electronics buck-boost converters. DC circuit breakers have solved the protection problems for both DC transmission and distribution system. In this paper 308V DC microgrid is proposed and home appliances (DC internal are modified to operate on 48V DC from DC distribution line. Instead of using universal and induction motors in rotary appliances, BLDC (Brushless DC motors are proposed that are highly efficient with minimum electro-mechanical and no commutation losses. Proposed DC system reduces the power conversion stages, hence diminishes the associated power losses and standby losses that boost the overall system efficiency. So in view of all this a conventional AC system can be replaced by a DC system that has many advantages by cost as well as by performance

  17. Assessment of perceived orthodontic appliance attractiveness.

    Science.gov (United States)

    Ziuchkovski, James P; Fields, Henry W; Johnston, William M; Lindsey, Delwin T

    2008-04-01

    To date, no studies have been published in the literature evaluating the esthetics of orthodontic appliances. The purpose of this study was to assess appliance variables, including appliance type, brand, wire, and ligature tie, for their relative attractiveness. Demographic factors were also evaluated. Appliances were placed in an adult, and digital images were captured, standardized, and incorporated into a computer-based survey. Subjects (n = 200) rated each image for attractiveness on a visual analog scale. The attractiveness ratings were analyzed by using factorial analysis of variance with repeated measures. Post-hoc testing was done with the Tukey-Kramer test (overall a appliances), ceramic, and all self-ligating/stainless steel appliances. No differences between brands in each appliance type were found. Ratings of some ceramic appliances were significantly affected by archwire and ligature tie, depending on several demographic interactions. Orthodontic appliance attractiveness varies by the following hierarchy of appliance types: alternative > ceramic > all stainless steel/self-ligating. Wire and tie selection can affect the appearance of ceramic appliances but have no impact on stainless steel or self-ligating appliances. Certain demographic factors have variable effects on attractiveness ratings.

  18. 24 CFR 3280.714 - Appliances, cooling.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Appliances, cooling. 3280.714... Systems § 3280.714 Appliances, cooling. (a) Every air conditioning unit or a combination air conditioning... accordance with ANSI Z21.40.1-1996, Gas Fired, Heat Activated, Air Conditioning and Heat Pump Appliances, and...

  19. 24 CFR 3285.503 - Optional appliances.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Optional appliances. 3285.503... appliances. (a) Comfort cooling systems. When not provided and installed by the home manufacturer, any comfort cooling systems that are installed must be installed according to the appliance manufacturer's...

  20. 49 CFR 238.429 - Safety appliances.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Safety appliances. 238.429 Section 238.429... Equipment § 238.429 Safety appliances. (a) Couplers. (1) The leading and the trailing ends of a semi... appliance mechanical strength and fasteners. (1) All handrails, handholds, and sill steps shall be made of 1...

  1. Energy in the residential building. Electricity, heat, e-mobility. 2. rev. and enl. ed.; Energie im Wohngebaeude. Strom, Waerme, E-Mobilitaet

    Energy Technology Data Exchange (ETDEWEB)

    Schwarzburger, Heiko

    2017-11-01

    Photovoltaics, heat pumps and fuel cells offer enormous potential for sustainable energy supply in residential buildings. Solar thermal energy and wood-fired boilers also play an important role in refurbishment. Due to the wide range of possible combinations, the wishes of building owners and homeowners for an ecologically and economically individually adapted energy concept can be fulfilled accurately. This book provides you with a holistic approach to the residential building and its supply of electricity, heat and water. All processes that play a role in the house's energy consumption are examined in their entirety for their potentials and potential savings. The author analyses and describes in detail the resources of buildings and their surroundings - and how they can be used for a truly independent supply. The focus is on reducing energy consumption and costs, the generation and supply of energy from renewable sources and energy storage - considered in new construction and modernisation. The supply of water is also dealt with if it touches on energy issues. The author draws attention to standards and regulations and gives practical advice for planning and installation. The focus is on the so-called sector coupling: electricity from the sun, wind and hydrogen is used to supply electrical consumers in the home, charging technology for electric vehicles, hot water and heating. The time of the boilers and combustion engines has elapsed. Clean electricity and digital controls - power and intelligence - determine the regenerative building technology. [German] Photovoltaik, Waermepumpen und Brennstoffzellen bieten enormes Potenzial, die Energieversorgung im Wohngebaeude nachhaltig zu gestalten. In der Sanierung spielen auch Solarthermie und Holzfeuerungen eine wichtige Rolle. Aufgrund der vielfaeltigen Kombinationsmoeglichkeiten lassen sich die Wuensche der Bauherren und Hausbesitzer nach einem oekologisch und oekonomisch individuell angepassten Energiekonzept

  2. The effect of utility time-varying pricing and load control strategies on residential summer peak electricity use. A review

    International Nuclear Information System (INIS)

    Newsham, Guy R.; Bowker, Brent G.

    2010-01-01

    Peak demand for electricity in North America is expected to grow, challenging electrical utilities to supply this demand in a cost-effective, reliable manner. Therefore, there is growing interest in strategies to reduce peak demand by eliminating electricity use, or shifting it to non-peak times. This strategy is commonly called 'demand response'. In households, common strategies are time-varying pricing, which charge more for energy use on peak, or direct load control, which allows utilities to curtail certain loads during high demand periods. We reviewed recent North American studies of these strategies. The data suggest that the most effective strategy is a critical peak price (CPP) program with enabling technology to automatically curtail loads on event days. There is little evidence that this causes substantial hardship for occupants, particularly if they have input into which loads are controlled and how, and have an override option. In such cases, a peak load reduction of at least 30% is a reasonable expectation. It might be possible to attain such load reductions without enabling technology by focusing on household types more likely to respond, and providing them with excellent support. A simple time-of-use (TOU) program can only expect to realise on-peak reductions of 5%. (author)

  3. Feedback as a means of decreasing residential energy consumption. Report PU/CES 34

    Energy Technology Data Exchange (ETDEWEB)

    Seligman, C; Darley, J M

    1976-08-01

    When residential units are analyzed in human factor terms, it is apparent that the consumption level feedback (typically a bill, calculated once a month, over all appliances) is inadequate to give the resident useful information about his energy consuming actions. The present study tested the hypothesis that providing immediate feedback to homeowners concerning their daily rate of electric usage would be effective in reducing electric consumption. In the studied homes, central air-conditioning is the largest single source of electric power consumption during the summer. Accordingly, it was possible to predict the household's expected electric consumption in terms of the average daily outdoor temperature. Predicted electric consumption was derived from a previous month's modeling period during which a regression line was fitted to predict consumption from average daily temperature, for each home. Feedback was expressed as a percentage of actual consumption over predicted consumption. Feedback was displayed to homeowners four times a week for approximately one month. The results confirmed the prediction. Before feedback began, the feedback and control groups were consuming electricity at approximately equal rates. During the feedback period, the feedback group used 10.5 percent less electricity. The effectiveness of the feedback procedure was explained in terms of its cueing, motivational, and commitment functions.

  4. Evaluating the energy and CO2 emissions impacts of shifts in residential water heating in the United States

    International Nuclear Information System (INIS)

    Sanders, Kelly T.; Webber, Michael E.

    2015-01-01

    Water heating represented nearly 13% of 2010 residential energy consumption making it an important target for energy conservation efforts. The objective of this work is to identify spatially-resolved strategies for energy conservation, since little analysis has been done to identify how regional characteristics affect the energy consumed for water heating. We present a first-order thermodynamic analysis, utilizing ab initio calculations and regression methods, to quantify primary energy consumption and CO 2 emissions with regional specificity by considering by considering local electricity mixes, heat rates, solar radiation profiles, heating degrees days, and water heating unit sales for 27 regions of the US. Results suggest that shifting from electric towards natural gas or solar water heating offered primary energy and CO 2 emission reductions in most US regions, but these reductions varied considerably according to regional electricity mix and solar resources. We find that regions that would benefit most from technology transitions, are often least likely to switch due to limited economic incentives. Our results suggest that federal energy factor metrics, which ignore upstream losses in power generation, are insufficient in informing consumers about the energy performance of residential end use appliances. - Highlights: • US energy factor ratings for water heaters ignore upstream losses. • Switching from electric storage water heating reduces CO 2 emissions in most US regions. • Regions with greatest potential for CO 2 avoidance are least likely to shift technologies. • Benefits vary significantly according to climate and regional electricity fuel mix

  5. Residential Waste

    DEFF Research Database (Denmark)

    Christensen, Thomas Højlund; Fruergaard, Thilde; Matsufuji, Y.

    2011-01-01

    are discussed in this chapter. Characterizing residential waste is faced with the problem that many residences already divert some waste away from the official collection systems, for example performing home composting of vegetable waste and garden waste, having their bundled newspaper picked up by the scouts...... twice a year or bringing their used furniture to the flea markets organized by charity clubs. Thus, much of the data available on residential waste represents collected waste and not necessarily all generated waste. The latter can only be characterized by careful studies directly at the source......, but such studies are very expensive if fair representation of both spatial and temporal variations should be obtained. In addition, onsite studies may affect the waste generation in the residence because of the increased focus on the issue. Residential waste is defined in different ways in different countries...

  6. Analysis of Cool Roof Coatings for Residential Demand Side Management in Tropical Australia

    Directory of Open Access Journals (Sweden)

    Wendy Miller

    2015-06-01

    Full Text Available Cool roof coatings have a beneficial impact on reducing the heat load of a range of building types, resulting in reduced cooling energy loads. This study seeks to understand the extent to which cool roof coatings could be used as a residential demand side management (DSM strategy for retrofitting existing housing in a constrained network area in tropical Australia where peak electrical demand is heavily influenced by residential cooling loads. In particular this study seeks to determine whether simulation software used for building regulation purposes can provide networks with the ‘impact certainty’ required by their DSM principles. The building simulation method is supported by a field experiment. Both numerical and experimental data confirm reductions in total consumption (kWh and energy demand (kW. The nature of the regulated simulation software, combined with the diverse nature of residential buildings and their patterns of occupancy, however, mean that simulated results cannot be extrapolated to quantify benefits to a broader distribution network. The study suggests that building data gained from regulatory simulations could be a useful guide for potential impacts of widespread application of cool roof coatings in this region. The practical realization of these positive impacts, however, would require changes to the current business model for the evaluation of DSM strategies. The study provides seven key recommendations that encourage distribution networks to think beyond their infrastructure boundaries, recognising that the broader energy system also includes buildings, appliances and people.

  7. Dynamic modeling of potentially conflicting energy reduction strategies for residential structures in semi-arid climates.

    Science.gov (United States)

    Hester, Nathan; Li, Ke; Schramski, John R; Crittenden, John

    2012-04-30

    Globally, residential energy consumption continues to rise due to a variety of trends such as increasing access to modern appliances, overall population growth, and the overall increase of electricity distribution. Currently, residential energy consumption accounts for approximately one-fifth of total U.S. energy consumption. This research analyzes the effectiveness of a range of energy-saving measures for residential houses in semi-arid climates. These energy-saving measures include: structural insulated panels (SIP) for exterior wall construction, daylight control, increased window area, efficient window glass suitable for the local weather, and several combinations of these. Our model determined that energy consumption is reduced by up to 6.1% when multiple energy savings technologies are combined. In addition, pre-construction technologies (structural insulated panels (SIPs), daylight control, and increased window area) provide roughly 4 times the energy savings when compared to post-construction technologies (window blinds and efficient window glass). The model also illuminated the importance variations in local climate and building configuration; highlighting the site-specific nature of this type of energy consumption quantification for policy and building code considerations. Published by Elsevier Ltd.

  8. The state of the residential fire fatality problem in Sweden: Epidemiology, risk factors, and event typologies.

    Science.gov (United States)

    Jonsson, Anders; Bonander, Carl; Nilson, Finn; Huss, Fredrik

    2017-09-01

    Residential fires represent the largest category of fatal fires in Sweden. The purpose of this study was to describe the epidemiology of fatal residential fires in Sweden and to identify clusters of events. Data was collected from a database that combines information on fatal fires with data from forensic examinations and the Swedish Cause of Death-register. Mortality rates were calculated for different strata using population statistics and rescue service turnout reports. Cluster analysis was performed using multiple correspondence analysis with agglomerative hierarchical clustering. Male sex, old age, smoking, and alcohol were identified as risk factors, and the most common primary injury diagnosis was exposure to toxic gases. Compared to non-fatal fires, fatal residential fires more often originated in the bedroom, were more often caused by smoking, and were more likely to occur at night. Six clusters were identified. The first two clusters were both smoking-related, but were separated into (1) fatalities that often involved elderly people, usually female, whose clothes were ignited (17% of the sample), (2) middle-aged (45-64years old), (often) intoxicated men, where the fire usually originated in furniture (30%). Other clusters that were identified in the analysis were related to (3) fires caused by technical fault, started in electrical installations in single houses (13%), (4) cooking appliances left on (8%), (5) events with unknown cause, room and object of origin (25%), and (6) deliberately set fires (7%). Fatal residential fires were unevenly distributed in the Swedish population. To further reduce the incidence of fire mortality, specialized prevention efforts that focus on the different needs of each cluster are required. Cooperation between various societal functions, e.g. rescue services, elderly care, psychiatric clinics and other social services, with an application of both human and technological interventions, should reduce residential fire

  9. Emissions from SF6 appliances in Norway. Additional report No. 2

    International Nuclear Information System (INIS)

    Gjarede, Anne Cathrine

    1999-01-01

    The report presents facts regarding the Norwegian SF 6 emissions and the significance for the Norwegian climatic gas accounts in order to evaluate whether 12-24 kV SF 6 appliances are environmentally acceptable. Estimations show that emissions from such equipment contribute with about 0.2 % of the total Norwegian CO 2 emissions in 1993. The SF 6 which is stored in electric appliances, may either be recycled or decomposed to more environmentally acceptable end products. The report concludes that the contribution to the greenhouse effects from SF 6 appliances is minimal

  10. Electricity Customers

    Science.gov (United States)

    Residential, commercial, and industrial customers each account for roughly one-third of the nation’s electricity use. The transportation sector also accounts for a small fraction of electricity, although it could increase.

  11. Strategies to optimize the electric energy use in non-residential buildings; Estrategias para eficientizar el uso de la energia electrica en edificios no residenciales

    Energy Technology Data Exchange (ETDEWEB)

    Castro Flores, J.; Morillon Galvez, D. [Comision Nacional para el Ahorro de Energia, Mexico, D. F. (Mexico)

    1995-12-31

    This paper presents the problems identified in non-residential buildings, where the inadequate use of energy is mainly shown in three points: inadequate technology and maintenance, wrong use and wrong habits in the energy use. The consequences of this situation in the ecological, politic and social environment were analyzed. In base of the problems detected the following strategies are proposed: An adequate project and design, retrofit, maintenance and users awareness for the rational energy use. The economic evaluation performed for the implementation of these strategies shows a significant saving potential of the electric power, with measures of null and low investment. [Espanol] Se presenta la problematica identificada en edificios no residenciales; donde el uso inadecuado de la energia electrica se manifiesta principalmente en tres puntos: tecnologia y mantenimiento inadecuados, y mal uso y costumbres de la energia. Se analizo las consecuencias de esta situacion en el ambito ecologico, economico, politico y social. Con base a la problematica se proponen las siguientes estrategias: un adecuado proyecto y diseno, retrofit, mantenimiento y concientizacion del usuario para el uso racional de la energia. La evaluacion economica realizada para implantar estas estrategias muestra un significativo potencial de ahorro de energia electrica, con medidas de nula y baja inversion.

  12. Strategies to optimize the electric energy use in non-residential buildings; Estrategias para eficientizar el uso de la energia electrica en edificios no residenciales

    Energy Technology Data Exchange (ETDEWEB)

    Castro Flores, J; Morillon Galvez, D [Comision Nacional para el Ahorro de Energia, Mexico, D. F. (Mexico)

    1996-12-31

    This paper presents the problems identified in non-residential buildings, where the inadequate use of energy is mainly shown in three points: inadequate technology and maintenance, wrong use and wrong habits in the energy use. The consequences of this situation in the ecological, politic and social environment were analyzed. In base of the problems detected the following strategies are proposed: An adequate project and design, retrofit, maintenance and users awareness for the rational energy use. The economic evaluation performed for the implementation of these strategies shows a significant saving potential of the electric power, with measures of null and low investment. [Espanol] Se presenta la problematica identificada en edificios no residenciales; donde el uso inadecuado de la energia electrica se manifiesta principalmente en tres puntos: tecnologia y mantenimiento inadecuados, y mal uso y costumbres de la energia. Se analizo las consecuencias de esta situacion en el ambito ecologico, economico, politico y social. Con base a la problematica se proponen las siguientes estrategias: un adecuado proyecto y diseno, retrofit, mantenimiento y concientizacion del usuario para el uso racional de la energia. La evaluacion economica realizada para implantar estas estrategias muestra un significativo potencial de ahorro de energia electrica, con medidas de nula y baja inversion.

  13. Indoor temperature changes after retrofit: inferences based on electricity billing data for nonparticipants and participants in the BPA Residential Weatherization Program

    Energy Technology Data Exchange (ETDEWEB)

    Hirst, E.; White, D.

    1985-07-01

    This report discusses changes in indoor temperatures in response to retrofit improvements. The data on which this analysis is based are from an evaluation of the Bonneville Power Administration (BPA) interim Residential Weatherization Program. The BPA program, operated through participating private and public utilities throughout the Pacific Northwest, offered financial assistance (generally a cash rebate) to encourage installation of energy-efficiency improvements to existing homes in the region. These retrofits included attic, wall, floor and heating duct insulation; storm windows and doors; clock thermostats; and caulking and weatherstripping. This program, which operated during 1982 and 1983, weatherized 104 thousand homes at a total cost to BPA of $157 million. In mid-1983, staff at Oak Ridge National Laboratory and Evaluation Research Corporation began an evaluation of the BPA program. The primary focus of this evaluation was assessment of the actual electricity saving that can be attributed to the program (Hirst, et al., 1985). These savings estimates were used to help assess the economic attractiveness of the program to participants, the BPA power system, and the Pacific Northwest region as a whole.

  14. Residential Mechanical Precooling

    Energy Technology Data Exchange (ETDEWEB)

    German, Alea [Davis Energy Group, Davis, CA (United States). Alliance for Residential Building Innovation (ARBI); Hoeschele, Marc [Davis Energy Group, Davis, CA (United States). Alliance for Residential Building Innovation (ARBI)

    2014-12-01

    Residential air conditioning (AC) represents a challenging load for many electric utilities with poor load factors. Mechanical precooling improves the load factor by shifting cooling operation from on-peak to off-peak hours. This provides benefits to utilities and the electricity grid, as well as to occupants who can take advantage of time-of-use (TOU) electricity rates. Performance benefits stem from reduced compressor cycling, and shifting condensing unit operation to earlier periods of the day when outdoor temperatures are more favorable to operational efficiency. Finding solutions that save energy and reduce demand on the electricity grid is an important national objective and supports key Building America goals. The Alliance for Residential Building Innovation team evaluated mechanical AC precooling strategies in homes throughout the United States. EnergyPlus modeling was used to evaluate two homes with different performance characteristics in seven climates. Results are applicable to new construction homes and most existing homes built in the last 10 years, as well as fairly efficient retrofitted homes. A successful off-peak AC strategy offers the potential for increased efficiency and improved occupant comfort, and promotes a more reliable and robust electricity grid. Demand response capabilities and further integration with photovoltaic TOU generation patterns provide additional opportunities to flatten loads and optimize grid impacts.

  15. Electricity rates in Canada, 1991

    International Nuclear Information System (INIS)

    1991-01-01

    Numerical data only are presented for monthly electricity costs (residential and commercial) for selected Canadian cities. Total electricity supply is broken down by province. Residential, urban and rural electricity costs, including taxation, are provided for selected Canadian cities. Calculations of electricity costs for commercial and residential sectors are tabulated by province. Historical data from 1974 are supplied

  16. Day-ahead stochastic economic dispatch of wind integrated power system considering demand response of residential hybrid energy system

    International Nuclear Information System (INIS)

    Jiang, Yibo; Xu, Jian; Sun, Yuanzhang; Wei, Congying; Wang, Jing; Ke, Deping; Li, Xiong; Yang, Jun; Peng, Xiaotao; Tang, Bowen

    2017-01-01

    Highlights: • Improving the utilization of wind power by the demand response of residential hybrid energy system. • An optimal scheduling of home energy management system integrating micro-CHP. • The scattered response capability of consumers is aggregated by demand bidding curve. • A stochastic day-ahead economic dispatch model considering demand response and wind power. - Abstract: As the installed capacity of wind power is growing, the stochastic variability of wind power leads to the mismatch of demand and generated power. Employing the regulating capability of demand to improve the utilization of wind power has become a new research direction. Meanwhile, the micro combined heat and power (micro-CHP) allows residential consumers to choose whether generating electricity by themselves or purchasing from the utility company, which forms a residential hybrid energy system. However, the impact of the demand response with hybrid energy system contained micro-CHP on the large-scale wind power utilization has not been analyzed quantitatively. This paper proposes an operation optimization model of the residential hybrid energy system based on price response, integrating micro-CHP and smart appliances intelligently. Moreover, a novel load aggregation method is adopted to centralize scattered response capability of residential load. At the power grid level, a day-ahead stochastic economic dispatch model considering demand response and wind power is constructed. Furthermore, simulation is conducted respectively on the modified 6-bus system and IEEE 118-bus system. The results show that with the method proposed, the wind power curtailment of the system decreases by 78% in 6-bus system. In the meantime, the energy costs of residential consumers and the operating costs of the power system reduced by 10.7% and 11.7% in 118-bus system, respectively.

  17. Research and Development of Natural Draft Ultra-Low Emissions Burners for Gas Appliances

    Energy Technology Data Exchange (ETDEWEB)

    Therkelsen, Peter [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Cheng, Robert [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sholes, Darren [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-08-31

    Combustion systems used in residential and commercial cooking appliances must be robust and easy to use while meeting air quality standards. Current air quality standards for cooking appliances are far greater than other stationary combustion equipment. By developing an advanced low emission combustion system for cooking appliances, the air quality impacts from these devices can be reduced. This project adapted the Lawrence Berkeley National Laboratory (LBNL) Ring-Stabilizer Burner combustion technology for residential and commercial natural gas fired cooking appliances (such as ovens, ranges, and cooktops). LBNL originally developed the Ring-Stabilizer Burner for a NASA funded microgravity experiment. This natural draft combustion technology reduces NOx emissions significantly below current SCAQMD emissions standards without post combustion treatment. Additionally, the Ring-Stabilizer Burner technology does not require the assistance of a blower to achieve an ultra-low emission lean premix flame. The research team evaluated the Ring-Stabilizer Burner and fabricated the most promising designs based on their emissions and turndown.

  18. Measure Guideline: Combustion Safety for Natural Draft Appliances Using Indoor Air

    Energy Technology Data Exchange (ETDEWEB)

    Brand, L.

    2014-04-01

    This measure guideline covers how to assess and carry out the combustion safety procedures for appliances and heating equipment that uses indoor air for combustion in low-rise residential buildings. Only appliances installed in the living space, or in an area freely communicating with the living space, vented alone or in tandem with another appliance are considered here. A separate measure guideline addresses combustion appliances located either within the living space in enclosed closets or side rooms or outside the living space in an adjacent area like an attic or garage that use outdoor air for combustion. This document is for inspectors, auditors, and technicians working in homes where energy upgrades are being conducted whether or not air infiltration control is included in the package of measures being applied. In the indoor combustion air case, guidelines summarized here are based on language provided in several of the codes to establish minimum requirements for the space using simplified prescriptive measures. In addition, building performance testing procedures are provided by testing agencies. The codes in combination with the test procedures offer comprehensive combustion safety coverage to address safety concerns, allowing inexperienced residential energy retrofit inspectors to effectively address combustion safety issues and allow energy retrofits to proceed.

  19. Residential carbon dioxide emissions in Canada. Impact of efficiency improvements and fuel substitution

    International Nuclear Information System (INIS)

    Ugursal, V.I.; FUng, A.S.

    1998-01-01

    The effect of improving house envelope, heating system and appliance efficiencies, and fuel substitution on the atmospheric emissions of carbon dioxide in the Canadian residential sector is studied based on simulation studies. The findings clearly indicate that improving appliance efficiency reduces the overall end-use energy consumption in the residential sector as well as the associated carbon dioxide emissions. However, the magnitude of the reduction in carbon dioxide emissions as a result of improving only appliance efficiencies is quite small. Significantly larger reductions can be obtained by improving house envelopes and heating/cooling systems in addition to improving appliance efficiencies. Fuel substitution for space and domestic hot water heating can also present a potential to reduce carbon dioxide emissions depending on the fuel substitution scenario adopted. (author)

  20. Energy data sourcebook for the US residential sector

    Energy Technology Data Exchange (ETDEWEB)

    Wenzel, T.P.; Koomey, J.G.; Sanchez, M. [and others

    1997-09-01

    Analysts assessing policies and programs to improve energy efficiency in the residential sector require disparate input data from a variety of sources. This sourcebook, which updates a previous report, compiles these input data into a single location. The data provided include information on end-use unit energy consumption (UEC) values of appliances and equipment efficiency; historical and current appliance and equipment market shares; appliances and equipment efficiency and sales trends; appliance and equipment efficiency standards; cost vs. efficiency data for appliances and equipment; product lifetime estimates; thermal shell characteristics of buildings; heating and cooling loads; shell measure cost data for new and retrofit buildings; baseline housing stocks; forecasts of housing starts; and forecasts of energy prices and other economic drivers. This report is the essential sourcebook for policy analysts interested in residential sector energy use. The report can be downloaded from the Web at http://enduse.lbl. gov/Projects/RED.html. Future updates to the report, errata, and related links, will also be posted at this address.

  1. Measurements of intermediate-frequency electric and magnetic fields in households

    Energy Technology Data Exchange (ETDEWEB)

    Aerts, Sam, E-mail: sam.aerts@intec.ugent.be [Department of Information Technology, Ghent University/iMinds, iGent, Technologiepark-Zwijnaarde 15, B-9052 Ghent (Belgium); Calderon, Carolina [Centre for Radiation, Chemical and Environmental Hazards, Public Health England, Chilton, Didcot, Oxon OX11 0RQ (United Kingdom); Valič, Blaž [Institute of Non-Ionizing Radiation (INIS), Pohorskega bataljona 215, Ljubljana 1000 (Slovenia); Maslanyj, Myron; Addison, Darren; Mee, Terry; Goiceanu, Cristian [Centre for Radiation, Chemical and Environmental Hazards, Public Health England, Chilton, Didcot, Oxon OX11 0RQ (United Kingdom); Verloock, Leen; Van den Bossche, Matthias [Department of Information Technology, Ghent University/iMinds, iGent, Technologiepark-Zwijnaarde 15, B-9052 Ghent (Belgium); Gajšek, Peter [Institute of Non-Ionizing Radiation (INIS), Pohorskega bataljona 215, Ljubljana 1000 (Slovenia); Vermeulen, Roel [Institute for Risk Assessment Sciences, Department of Environmental Epidemiology, Utrecht University, Yalelaan 2, 3508 Utrecht (Netherlands); Röösli, Martin [Swiss Tropical and Public Health Institute (Swiss TPH), Socinstrasse 57, P.O. Box, 4002 Basel (Switzerland); University of Basel, Petersplatz 1, 4003 Basel (Switzerland); Cardis, Elisabeth [Barcelona Institute for Global Health (ISGlobal) and Municipal Institute of Medical Research (IMIM-Hospital del Mar), Doctor Aiguader, 88, 08003 Barcelona (Spain); Martens, Luc; Joseph, Wout [Department of Information Technology, Ghent University/iMinds, iGent, Technologiepark-Zwijnaarde 15, B-9052 Ghent (Belgium)

    2017-04-15

    Historically, assessment of human exposure to electric and magnetic fields has focused on the extremely-low-frequency (ELF) and radiofrequency (RF) ranges. However, research on the typically emitted fields in the intermediate-frequency (IF) range (300 Hz to 1 MHz) as well as potential effects of IF fields on the human body remains limited, although the range of household appliances with electrical components working in the IF range has grown significantly (e.g., induction cookers and compact fluorescent lighting). In this study, an extensive measurement survey was performed on the levels of electric and magnetic fields in the IF range typically present in residences as well as emitted by a wide range of household appliances under real-life circumstances. Using spot measurements, residential IF field levels were found to be generally low, while the use of certain appliances at close distance (20 cm) may result in a relatively high exposure. Overall, appliance emissions contained either harmonic signals, with fundamental frequencies between 6 kHz and 300 kHz, which were sometimes accompanied by regions in the IF spectrum of rather noisy, elevated field strengths, or much more capricious spectra, dominated by 50 Hz harmonics emanating far in the IF domain. The maximum peak field strengths recorded at 20 cm were 41.5 V/m and 2.7 A/m, both from induction cookers. Finally, none of the appliance emissions in the IF range exceeded the exposure summation rules recommended by the International Commission on Non-Ionizing Radiation Protection guidelines and the International Electrotechnical Commission (IEC 62233) standard at 20 cm and beyond (maximum exposure quotients EQ{sub E} 1.0 and {sub E}Q{sub H} 0.13). - Highlights: • Survey of residential electric and magnetic fields at intermediate frequencies (IF). • IF-EF and -MF emitted by 280 household appliances were characterised. • Strongest emitters were induction cookers, CFLs, LCD-TVs, and microwave ovens. • No

  2. Measurements of intermediate-frequency electric and magnetic fields in households

    International Nuclear Information System (INIS)

    Aerts, Sam; Calderon, Carolina; Valič, Blaž; Maslanyj, Myron; Addison, Darren; Mee, Terry; Goiceanu, Cristian; Verloock, Leen; Van den Bossche, Matthias; Gajšek, Peter; Vermeulen, Roel; Röösli, Martin; Cardis, Elisabeth; Martens, Luc; Joseph, Wout

    2017-01-01

    Historically, assessment of human exposure to electric and magnetic fields has focused on the extremely-low-frequency (ELF) and radiofrequency (RF) ranges. However, research on the typically emitted fields in the intermediate-frequency (IF) range (300 Hz to 1 MHz) as well as potential effects of IF fields on the human body remains limited, although the range of household appliances with electrical components working in the IF range has grown significantly (e.g., induction cookers and compact fluorescent lighting). In this study, an extensive measurement survey was performed on the levels of electric and magnetic fields in the IF range typically present in residences as well as emitted by a wide range of household appliances under real-life circumstances. Using spot measurements, residential IF field levels were found to be generally low, while the use of certain appliances at close distance (20 cm) may result in a relatively high exposure. Overall, appliance emissions contained either harmonic signals, with fundamental frequencies between 6 kHz and 300 kHz, which were sometimes accompanied by regions in the IF spectrum of rather noisy, elevated field strengths, or much more capricious spectra, dominated by 50 Hz harmonics emanating far in the IF domain. The maximum peak field strengths recorded at 20 cm were 41.5 V/m and 2.7 A/m, both from induction cookers. Finally, none of the appliance emissions in the IF range exceeded the exposure summation rules recommended by the International Commission on Non-Ionizing Radiation Protection guidelines and the International Electrotechnical Commission (IEC 62233) standard at 20 cm and beyond (maximum exposure quotients EQ E 1.0 and E Q H 0.13). - Highlights: • Survey of residential electric and magnetic fields at intermediate frequencies (IF). • IF-EF and -MF emitted by 280 household appliances were characterised. • Strongest emitters were induction cookers, CFLs, LCD-TVs, and microwave ovens. • No emissions exceeded

  3. Post-Retrofit Residential Assessments

    Energy Technology Data Exchange (ETDEWEB)

    Lancaster, Ross; lutzenhiser, Loren; Moezzi, Mithra; Widder, Sarah H.; Chandra, Subrato; Baechler, Michael C.

    2012-04-30

    This study examined a range of factors influencing energy consumption in households that had participated in residential energy-efficiency upgrades. The study was funded by a grant from the U.S. Department of Energy’s Pacific Northwest National Laboratory and was conducted by faculty and staff of Portland State University Center for Urban Studies and Department of Economics. This work was made possible through the assistance and support of the Energy Trust of Oregon (ETO), whose residential energy-efficiency programs provided the population from which the sample cases were drawn. All households in the study had participated in the ETO Home Performance with Energy Star (HPwES) program. A number of these had concurrently pursued measures through other ETO programs. Post-retrofit energy outcomes are rarely investigated on a house-by-house basis. Rather, aggregate changes are ordinarily the focus of program impact evaluations, with deviation from aggregate expectations chalked up to measurement error, the vagaries of weather and idiosyncrasies of occupants. However, understanding how homes perform post-retrofit on an individual basis can give important insights to increase energy savings at the participant and the programmatic level. Taking a more disaggregated approach, this study analyzed energy consumption data from before and after the retrofit activity and made comparisons with engineering estimates for the upgrades, to identify households that performed differently from what may have been expected based on the estimates. A statistical analysis using hierarchal linear models, which accounted for weather variations, was performed looking separately at gas and electrical use during the periods before and after upgrades took place. A more straightforward comparison of billing data for 12-month periods before and after the intervention was also performed, yielding the majority of the cases examined. The later approach allowed total energy use and costs to be

  4. Field performance of wood-burning and coal-burning appliances in Crested Butte during the 1989-90 heating season. Final report

    International Nuclear Information System (INIS)

    Jaasma, D.R.; Champion, M.R.; Gundappa, M.

    1991-10-01

    The field performance of woodburning and coalburning appliances in and around Crested Butte, CO, has been evaluated. Measurements included particulate matter (PM), carbon monoxide (CO), and weekly average burn rates. Woodburning appliances included conventional airtight stoves, EPA-certified catalytic stoves, and EPA-certified noncatalytic stoves. Compared to the emissions measured from conventional stoves, the certified stoves reduced PM emission factors (g/kg) by 53% and CO emission factors by 49%. Coalburning appliances included a commercial scale boiler, a residential stoker, and hand-fired coalstove. The coalburning appliances were compared to conventional woodstoves on a grams of pollutant per joule of heat output basis. The automatically stoked coal appliances reduced PM and CO emissions by roughly 84% and 85%, respectively. The hand-fired stove was cleaner than expected, reducing PM by 55% and CO by 27%

  5. California DREAMing: The design of residential demand responsive technology with people in mind

    Science.gov (United States)

    Peffer, Therese Evelyn

    Electrical utilities worldwide are exploring "demand response" programs to reduce electricity consumption during peak periods. Californian electrical utilities would like to pass the higher cost of peak demand to customers to offset costs, increase reliability, and reduce peak consumption. Variable pricing strategies require technology to communicate a dynamic price to customers and respond to that price. However, evidence from thermostat and energy display studies as well as research regarding energy-saving behaviors suggests that devices cannot effect residential demand response without the sanction and participation of people. This study developed several technologies to promote or enable residential demand response. First, along with a team of students and professors, I designed and tested the Demand Response Electrical Appliance Manager (DREAM). This wireless network of sensors, actuators, and controller with a user interface provides information to intelligently control a residential heating and cooling system and to inform people of their energy usage. We tested the system with computer simulation and in the laboratory and field. Secondly, as part of my contribution to the team, I evaluated machine-learning to predict a person's seasonal temperature preferences by analyzing existing data from office workers. The third part of the research involved developing an algorithm that generated temperature setpoints based on outdoor temperature. My study compared the simulated energy use using these setpoints to that using the setpoints of a programmable thermostat. Finally, I developed and tested a user interface for a thermostat and in-home energy display. This research tested the effects of both energy versus price information and the context of sponsorship on the behavior of subjects. I also surveyed subjects on the usefulness of various displays. The wireless network succeeded in providing detailed data to enable an intelligent controller and provide feedback to

  6. Policy instruments force climate protection by increasing the energy efficiency of electric appliances and electrical systems in private households and the commercial and small-scale sector; Politikinstrumente zur Effizienzsteigerung von Elektrogeraeten und -anlagen in Privathaushalten, Bueros und im Kleinverbrauch

    Energy Technology Data Exchange (ETDEWEB)

    Duscha, Markus; Seebach, Dominik; Griessmann, Benjamin [ifeu-Institut fuer Energie- und Umweltforschung GmbH, Heidelberg (Germany)

    2006-06-15

    The implementation of new, more market-oriented instruments represents an additional starting point for future developments. This path was started on in the EU in 2005 with the CO{sub 2} emission trade. The price signals that could be expected for end customers in households and trade from this alone would most likely be too low to be a sufficient motivation for exhausting the electricity efficiency potential. At this point, we must again point out that only rarely are there economic hindrances to the complete use of potential, but rather a lack of information and organization leads to increased transaction costs in the implementation. This must be corrected by accompanying efficiency instruments and programs. However, implementing these programs does not (yet) represent an economic alternative to the efficiency measures in their own systems for the industry and power company involved in the emission trade due to such transaction costs. Otherwise there would be initiatives in the meantime for this type of privately organized program, as these have been suggested in this report as tasks for a national electricity fund. Therefore, the instrument of the EU emission trade must be supplemented in the foreseeable future with the instruments presented here. There is not much evidence as to how much a comparable implementation of tradable energy efficiency certificates (often referred to as ''white certificates'') is a suitable start for concluding efficiency potential at the level of the very inhomogeneous group of end consumers. We still see a need for research before such an instrument can be recommended as a guide for Germany or even Europe. The questions still to be clarified include, among other things, the ability of standardizing the assignment rules as well as the amount of the transaction costs to be expected, even in dependency on the market level at which the trade is started (end consumer, energy service provider, electronic equipment

  7. Discover the benefits of residential wood heating

    International Nuclear Information System (INIS)

    2003-01-01

    This publication described how residential wood-heating systems are being used to reduce energy costs and increase home comfort. Biomass energy refers to all forms are renewable energy that is derived from plant materials. The source of fuel may include sawmills, woodworking shops, forest operations and farms. The combustion of biomass is also considered to be carbon dioxide neutral, and is not considered to be a major producer of greenhouse gases (GHG) linked to global climate change. Wood burning does, however, release air pollutants, particularly if they are incompletely burned. Incomplete combustion of wood results in dense smoke consisting of toxic gases. Natural Resources Canada helped create new safety standards and the development of the Wood Energy Technical Training Program to ensure that all types of wood-burning appliances are installed correctly and safely to reduce the risk of fire and for effective wood heating. In Canada, more than 3 million families heat with wood as a primary or secondary heating source in homes and cottages. Wood heating offers security from energy price fluctuations and electrical power failures. This paper described the benefits of fireplace inserts that can transform old fireplaces into modern heating systems. It also demonstrated how an add-on wood furnace can be installed next to oil furnaces to convert an oil-only heating system to a wood-oil combination system, thereby saving thousands of dollars in heating costs. Wood pellet stoves are another wood burning option. The fuel for the stoves is produced from dried, finely ground wood waste that is compressed into hard pellets that are loaded into a hopper. The stove can run automatically for up to 24 hours. New high-efficiency advanced fireplaces also offer an alternative heating system that can reduce heating costs while preserving Canada's limited supply of fossil fuels such as oil and gas. 13 figs

  8. The barriers to energy efficiency in China: Assessing household electricity savings and consumer behavior in Liaoning Province

    International Nuclear Information System (INIS)

    Feng Dianshu; Sovacool, Benjamin K.; Khuong Minh Vu

    2010-01-01

    This article investigates the barriers to energy efficiency at the residential sector within one province in China and explores patterns of household electricity consumption. The article presents the results of a survey questionnaire distributed to more than 600 households in Liaoning Province, field research at various Liaoning government agencies, and research interviews of Liaoning government officials to determine the efficacy of their energy efficiency efforts in China. It then investigates the extent that electricity consumers have taken advantage of energy efficiency opportunities relating to more efficient lights, water heaters, appliances, air-conditioners and heaters, and better energy-efficiency labels. The article also assesses the degree that electricity users have become more aware about electricity prices and their levels of consumption, and touches on the connection between rising levels of income and electricity use. It concludes by providing recommendations for how to improve efforts to promote conservation and reduce electricity load growth in Liaoning Province and beyond.

  9. The barriers to energy efficiency in China. Assessing household electricity savings and consumer behavior in Liaoning Province

    Energy Technology Data Exchange (ETDEWEB)

    Dianshu, Feng; Sovacool, Benjamin K.; Minh Vu, Khuong [Lee Kuan Yew School of Public Policy, Centre on Asia and Globalisation, National University of Singapore, Oei Tiong Ham Building, 469C Bukit Timah Road, Singapore 259772 (Singapore)

    2010-02-15

    This article investigates the barriers to energy efficiency at the residential sector within one province in China and explores patterns of household electricity consumption. The article presents the results of a survey questionnaire distributed to more than 600 households in Liaoning Province, field research at various Liaoning government agencies, and research interviews of Liaoning government officials to determine the efficacy of their energy efficiency efforts in China. It then investigates the extent that electricity consumers have taken advantage of energy efficiency opportunities relating to more efficient lights, water heaters, appliances, air-conditioners and heaters, and better energy-efficiency labels. The article also assesses the degree that electricity users have become more aware about electricity prices and their levels of consumption, and touches on the connection between rising levels of income and electricity use. It concludes by providing recommendations for how to improve efforts to promote conservation and reduce electricity load growth in Liaoning Province and beyond. (author)

  10. The barriers to energy efficiency in China: Assessing household electricity savings and consumer behavior in Liaoning Province

    Energy Technology Data Exchange (ETDEWEB)

    Feng Dianshu, E-mail: dianshu@nus.edu.s [Lee Kuan Yew School of Public Policy, Centre on Asia and Globalisation, National University of Singapore, Oei Tiong Ham Building, 469C Bukit Timah Road, Singapore 259772 (Singapore); Sovacool, Benjamin K., E-mail: bsovacool@nus.edu.s [Lee Kuan Yew School of Public Policy, Centre on Asia and Globalisation, National University of Singapore, Oei Tiong Ham Building, 469C Bukit Timah Road, Singapore 259772 (Singapore); Khuong Minh Vu, E-mail: sppkmv@nus.edu.s [Lee Kuan Yew School of Public Policy, Centre on Asia and Globalisation, National University of Singapore, Oei Tiong Ham Building, 469C Bukit Timah Road, Singapore 259772 (Singapore)

    2010-02-15

    This article investigates the barriers to energy efficiency at the residential sector within one province in China and explores patterns of household electricity consumption. The article presents the results of a survey questionnaire distributed to more than 600 households in Liaoning Province, field research at various Liaoning government agencies, and research interviews of Liaoning government officials to determine the efficacy of their energy efficiency efforts in China. It then investigates the extent that electricity consumers have taken advantage of energy efficiency opportunities relating to more efficient lights, water heaters, appliances, air-conditioners and heaters, and better energy-efficiency labels. The article also assesses the degree that electricity users have become more aware about electricity prices and their levels of consumption, and touches on the connection between rising levels of income and electricity use. It concludes by providing recommendations for how to improve efforts to promote conservation and reduce electricity load growth in Liaoning Province and beyond.

  11. What can we learn from high-frequency appliance-level energy metering? Results from a field experiment

    International Nuclear Information System (INIS)

    Chen, Victor L.; Delmas, Magali A.; Kaiser, William J.; Locke, Stephen L.

    2015-01-01

    This study uses high-frequency appliance-level electricity consumption data for 124 apartments over 24 months to provide a better understanding of appliance-level electricity consumption behavior. We conduct our analysis in a standardized set of apartments with similar appliances, which allows us to identify behavioral differences in electricity use. The Results show that households' estimations of appliance-level consumption are inaccurate and that they overestimate lighting use by 75% and underestimate plug-load use by 29%. We find that similar households using the same major appliances exhibit substantial variation in appliance-level electricity consumption. For example, households in the 75th percentile of HVAC usage use over four times as much electricity as a user in the 25th percentile. Additionally, we show that behavior accounts for 25–58% of this variation. Lastly, we find that replacing the existing refrigerator with a more energy-efficient model leads to overall energy savings of approximately 11%. This is equivalent to results from behavioral interventions targeting all appliances but might not be as cost effective. Our findings have important implications for behavior-based energy conservation policies. - Highlights: • Hourly electricity usage was collected from 124 comparable apartments for 24 months. • Households overestimate lighting use by 75% and underestimate HVAC usage by 29%. • Households using the same appliances show substantial variations in electricity use. • Plug load accounts for the largest share of electricity use at all hours of the day. • Savings of 11% were achieved by replacing old refrigerators

  12. Microbiologically influenced corrosion of orthodontic metallic appliances.

    Science.gov (United States)

    Kameda, Takashi; Oda, Hirotake; Ohkuma, Kazuo; Sano, Natsuki; Batbayar, Nomintsetseg; Terashima, Yukari; Sato, Soh; Terada, Kazuto

    2014-01-01

    Biocorrosion (microbiologically influenced corrosion; MIC) occur in aquatic habitats varying in nutrient content, temperature, stress and pH. The oral environment of organisms, including humans, should be one of the most hospitable for MIC. Corrosion of metallic appliances in the oral region is one cause of metal allergy in patients. In this study, an inductively coupled plasma-optical emission spectrometer revealed elution of Fe, Cr and Ni from stainless steel (SUS) appliances incubated with oral bacteria. Three-dimensional laser confocal microscopy also revealed that oral bacterial culture promoted increased surface roughness and corrosion pits in SUS appliances. The pH of the supernatant was lowered after co-culture of appliances and oral bacteria in any combinations, but not reached at the level of depassivation pH of their metallic materials. This study showed that Streptococcus mutans and Streptococcus sanguinis which easily created biofilm on the surfaces of teeth and appliances, did corrode orthodontic SUS appliances.

  13. 24 CFR 3280.709 - Installation of appliances.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Installation of appliances. 3280... Fuel Burning Systems § 3280.709 Installation of appliances. (a) The installation of each appliance... the manufacturer's instructions attached to the appliance. Every appliance shall be secured in place...

  14. 24 CFR 3280.707 - Heat producing appliances.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Heat producing appliances. 3280.707... Systems § 3280.707 Heat producing appliances. (a) Heat-producing appliances and vents, roof jacks and... appliance, the heating appliance shall be installed by the manufacturer of the manufactured home in...

  15. Particulate emissions from residential wood combustion

    DEFF Research Database (Denmark)

    Luis Teles de Carvalho, Ricardo; Jensen, Ole Michael; Tarelho, Luis A. C.

    Residential wood combustion (RWC) in fireplaces and conventional appliances is the main contributor to fine particulate matter (PM2.5) emissions in Denmark and Portugal representing more than 30% of the total emissions [1;2]. Such estimations are uncertain concerning the wood consumption...... and official emission factors, not taking into account actual burning conditions in dwellings [3]. There is limited knowledge on the real-life performance and spatial distribution of existing appliance types. Few studies have been targeting to understand the influence of fuel operation habits on PM2...... the available estimations for Denmark and Portugal, suggesting a methodology to increase the accuracy of activity data and emission factors. This work is based on new studies carried out to quantify the PM2.5 emissions in daily life through field experiments in Danish dwellings and by considering typical...

  16. Designing appliances for mobile commerce and retailtainment

    OpenAIRE

    Roussos, George; Kourouthanassis, P.; Moussouri, T.

    2003-01-01

    In the emerging world of the new consumer and the `anytime, anywhere' mobile commerce, appliances are located at the collision point of the retailer and consumer agendas. The consequence of this is twofold: on the one hand appliances that were previously considered plain and utilitarian become entertainment devices and on the other, for the effective design of consumer appliances it becomes paramount to employ multidisciplinary expertise. In this paper, we discuss consumer perceptions of a re...

  17. Key Residential Building Equipment Technologies for Control and Grid Support PART I (Residential)

    Energy Technology Data Exchange (ETDEWEB)

    Starke, Michael R [ORNL; Onar, Omer C [ORNL; DeVault, Robert C [ORNL

    2011-09-01

    based on the largest electrical energy consumers in the residential sector are space heating and cooling, washer and dryer, water heating, lighting, computers and electronics, dishwasher and range, and refrigeration. As the largest loads, these loads provide the highest potential for delivering demand response and reliability services. Many residential loads have inherent flexibility that is related to the purpose of the load. Depending on the load type, electric power consumption levels can either be ramped, changed in a step-change fashion, or completely removed. Loads with only on-off capability (such as clothes washers and dryers) provide less flexibility than resources that can be ramped or step-changed. Add-on devices may be able to provide extra demand response capabilities. Still, operating residential loads effectively requires awareness of the delicate balance of occupants health and comfort and electrical energy consumption. This report is Phase I of a series of reports aimed at identifying gaps in automated home energy management systems for incorporation of building appliances, vehicles, and renewable adoption into a smart grid, specifically with the intent of examining demand response and load factor control for power system support. The objective is to capture existing gaps in load control, energy management systems, and sensor technology with consideration of PHEV and renewable technologies to establish areas of research for the Department of Energy. In this report, (1) data is collected and examined from state of the art homes to characterize the primary residential loads as well as PHEVs and photovoltaic for potential adoption into energy management control strategies; and (2) demand response rules and requirements across the various demand response programs are examined for potential participation of residential loads. This report will be followed by a Phase II report aimed at identifying the current state of technology of energy management systems

  18. Fibrotic encapsulation of orthodontic appliance in palate.

    Science.gov (United States)

    Muthu, Jananni; Muthanandam, Sivaramakrishnan; Umapathy, Gubernath; Kannan, Anitha Logaranjani

    2017-01-01

    Iatrogenic trauma though not serious is very common in dental practice. Orthodontic treatment can inflict such injuries as they are prolonged over a long period of time. Ill-fabricated orthodontic appliances, such as wires and brackets, or the patients' habits such as application of constant pressure over the appliance can traumatize the adjacent oral soft tissues. In rare cases, these appliances can get embedded into the mucosa and gingival tissues. This case report describes one such case of iatrogenic trauma to the palatal mucosa due to entrapment of a tongue spike appliance and its surgical management.

  19. Dynamic Appliances Scheduling in Collaborative MicroGrids System

    Science.gov (United States)

    Bilil, Hasnae; Aniba, Ghassane; Gharavi, Hamid

    2017-01-01

    In this paper a new approach which is based on a collaborative system of MicroGrids (MG’s), is proposed to enable household appliance scheduling. To achieve this, appliances are categorized into flexible and non-flexible Deferrable Loads (DL’s), according to their electrical components. We propose a dynamic scheduling algorithm where users can systematically manage the operation of their electric appliances. The main challenge is to develop a flattening function calculus (reshaping) for both flexible and non-flexible DL’s. In addition, implementation of the proposed algorithm would require dynamically analyzing two successive multi-objective optimization (MOO) problems. The first targets the activation schedule of non-flexible DL’s and the second deals with the power profiles of flexible DL’s. The MOO problems are resolved by using a fast and elitist multi-objective genetic algorithm (NSGA-II). Finally, in order to show the efficiency of the proposed approach, a case study of a collaborative system that consists of 40 MG’s registered in the load curve for the flattening program has been developed. The results verify that the load curve can indeed become very flat by applying the proposed scheduling approach. PMID:28824226

  20. Domestic appliances energy optimization with model predictive control

    International Nuclear Information System (INIS)

    Rodrigues, E.M.G.; Godina, R.; Pouresmaeil, E.; Ferreira, J.R.; Catalão, J.P.S.

    2017-01-01

    Highlights: • An alternative power management control for home appliances that require thermal regulation is presented. • A Model Predictive Control scheme is assessed and its performance studied and compared to the thermostat. • Problem formulation is explored through tuning weights with the aim of reducing energetic consumption and cost. • A modulation scheme of a two-level Model Predictive Control signal as an interface block is presented. • The implementation costs in home appliances with thermal regulation requirements are reduced. - Abstract: A vital element in making a sustainable world is correctly managing the energy in the domestic sector. Thus, this sector evidently stands as a key one for to be addressed in terms of climate change goals. Increasingly, people are aware of electricity savings by turning off the equipment that is not been used, or connect electrical loads just outside the on-peak hours. However, these few efforts are not enough to reduce the global energy consumption, which is increasing. Much of the reduction was due to technological improvements, however with the advancing of the years new types of control arise. Domestic appliances with the purpose of heating and cooling rely on thermostatic regulation technique. The study in this paper is focused on the subject of an alternative power management control for home appliances that require thermal regulation. In this paper a Model Predictive Control scheme is assessed and its performance studied and compared to the thermostat with the aim of minimizing the cooling energy consumption through the minimization of the energy cost while satisfying the adequate temperature range for the human comfort. In addition, the Model Predictive Control problem formulation is explored through tuning weights with the aim of reducing energetic consumption and cost. For this purpose, the typical consumption of a 24 h period of a summer day was simulated a three-level tariff scheme was used. The new

  1. Turkey’s Strategic Energy Efficiency Plan – An ex ante impact assessment of the residential sector

    International Nuclear Information System (INIS)

    Elsland, Rainer; Divrak, Can; Fleiter, Tobias; Wietschel, Martin

    2014-01-01

    Turkey’s energy demand has been growing by 4.5% per year over the last decade. As a reaction to this, the Turkish government has implemented the Strategic Energy Efficiency Plan (SEEP), which provides a guideline for energy efficiency policies in all sectors. The aim of this study is to analyse the potential of the SEEP on final energy demand in the Turkish residential sector until 2030. Three scenarios are developed based on a detailed bottom-up modelling approach using a vintage stock model to simulate the energy demand of heating systems and appliances. The results show a decreasing final energy demand in the reference scenario from about 944 PJ in 2008 to 843 PJ in 2030. This reflects a structural break, which is mainly caused by a high building demolition rate and low efficiency in the existing building stock. The SEEP achieves additional savings of around 111 PJ until 2030, while a scenario with even higher efficiency shows further savings of 91 PJ. Electricity demand increases in all scenarios – mainly due to growing ownership rates of appliances. The SEEP will achieve around 10 TWh of electricity savings in 2030 compared to the reference scenario, mainly through more ambitious end-use standards

  2. Inventory of usage pattern for wood burning appliances

    International Nuclear Information System (INIS)

    Cooper, David; Joeborn, Inger; Sjoedin, Aake; Munkhammar, Inger; Gustavsson, Lennart

    2005-02-01

    The Swedish Environmental Research Institute (IVL) in co-operation with the Swedish National Testing and Research Institute (SP) and Statistics Sweden (SCB) have investigated the use of domestic wood burning for wood stoves and open fireplaces. The results from a closer examination of existing national energy statistics for residential heating has enabled a division of the average consumption of firewood for each house by the category 'fireplace for open fire' and 'tiled stove/heating stove/fireplace for wood'. The estimation of emissions can therefore be improved by differentiating emission factors for different wood stoves and open fireplaces. Today, only one emission factor is used. An insight into general firing procedures, wood storage routines etc. was investigated using a questionnaire for the Teleborg area of the city Vaexjoe. The results of this study provide a foundation for further work, which will subsequently enable improvements for emission inventories on small-scale biomass combustion from household appliances

  3. Residential greenhouse

    Energy Technology Data Exchange (ETDEWEB)

    1985-02-01

    The following report examines the technical and economic viability of residential greenhouse additions in Whitehorse, Yukon. The greenhouse was constructed using the south facing wall of an existing residence as a common wall. Total construction costs were $18,000, including labour. Annual fuel demand for the residence has been reduced by about 10 per cent for an annual saving of $425. In addition, produce to the value of $1,000 is grown annually in the greenhouse for domestic consumption and commercial resale. Typically the greenhouse operates for nine months each year. There is a net thermal loss during the months of November, December and January as a result of the large area of glazing. As well as supplementing the heating supply solar greenhouses can provide additional cash crops which can be used to offset the cost of construction. Humidity problems are minimal and can be dealt with by exhausting high humidity air. One system which has been considered for the greenhouse is to use a standard residential heat pump to remove excess moisture and to pump heat into the house. This would have a secondary benefit of excluding the need to circulate greenhouse air through the house. Thus any allergenic reactions to the greenhouse air would be prevented. 8 refs., 3 figs, 2 tabs.

  4. Custom Made Pressure Appliance for Presurgical Sustained ...

    African Journals Online (AJOL)

    Among the most common complications of this therapy is ulceration due to excessive pressure. A case of presurgical size reduction for a large ear keloid with a custom made pressure appliance is presented. This novel design of the appliance allows for better control over the amount and direction of the pressure applied on ...

  5. Hydrophilic structures for condensation management in appliances

    Science.gov (United States)

    Kuehl, Steven John; Vonderhaar, John J.; Wu, Guolian; Wu, Mianxue

    2016-02-02

    An appliance that includes a cabinet having an exterior surface; a refrigeration compartment located within the cabinet; and a hydrophilic structure disposed on the exterior surface. The hydrophilic structure is configured to spread condensation. The appliance further includes a wicking structure located in proximity to the hydrophilic structure, and the wicking structure is configured to receive the condensation.

  6. Motor-pump unit provided with a lifting appliance of the motor

    International Nuclear Information System (INIS)

    Veronesi, Luciano; Francis, W.R.

    1978-01-01

    This invention relates to lifting appliances and particularly concerns a 'pump and motor set' or motor-pump unit fitted with a lifting appliance enabling the motor to be separated from the pump. In nuclear power stations the reactor discharges heat that is carried by the coolant to a distant point away from the reactor to generate steam and electricity conventionally. In order to cause the reactor coolant to flow through the system, coolant motor-pump units are provided in the cooling system. These units are generally of the vertical type with an electric motor fitted vertically on the pump by means of a cylindrical or conical structure called motor support [fr

  7. Economic impacts of current harmonic from nonlinear loads on residential electricity distribution networks; Impactos economicos dos harmonicos de corrente das cargas nao lineares em redes eletricas de distribuicao residenciais

    Energy Technology Data Exchange (ETDEWEB)

    Duarte, Carlos Henrique

    2010-04-15

    To achieve more efficient energy use, power electronics systems (PES) may be employed. However, this introduce nonlinear loads into the system by generating undesired frequencies that are harmonic in relation to (multiples of) the fundamental frequency (60 Hz in Brazil). Consequently, devices using PES (power electronics systems) are more efficient but also contribute significantly to degradation of power quality. Besides this, both the conventional rules on design and operation of power systems and the usual premises followed in energy efficiency programs (without mentioning the electricity consumed by the devices themselves) consider the sinusoidal voltage and current waveforms at the fixed fundamental frequency (60 Hz in Brazil) of the power grid. Thus, analysis of electricity consumption reductions in energy efficiency programs that include the use of PES considers the reduction of kWh to the final consumer but not the additional losses caused by the increase in harmonic distortion. This dissertation investigates this problem by exploring a case study of the ownership and use of television sets (TV sets) to estimate the economic impacts of residential PES on a mainly residential electricity distribution system. (author)

  8. Energy and associated greenhouse gas emissions from household appliances in Malaysia

    International Nuclear Information System (INIS)

    Saidur, R.; Masjuki, H.H.; Jamaluddin, M.Y.; Ahmed, S.

    2007-01-01

    Today, electricity is an indispensable key for civilization and development. The trend of electricity consumption is rather escalating. Electricity generation principally depends upon fossil fuels. In one hand, the stocks of these fuels have been confirmed to be critically limited. On the other hand, in process of electricity generation by means of these fuels, a number of poisonous by-products adversely affect the conservation of natural eco-system. Further, electricity driven appliances use emanate anti-environmental gases that also affect human health and climate. Therefore, estimation of energy consumption for operating household appliances, savings of energy under policy intervention, and emission of poisonous gases in a fast developing country deserve academic attention. This paper focuses on estimation of energy consumption, energy savings, reduction of emissions of greenhouse gases for use of household appliances in Malaysia between 1999 and 2015. In the upstream side of electricity generation, the study estimates the amount of greenhouse gases (GHGs) resulting from burning of fossil fuels. In downstream side, it considers the energy savings and reduction of CHGs. The results show that significant amount of energy can be saved and thus huge volume of toxic emissions can be controlled. The findings can be useful to policy makers as well as household appliances users

  9. Minat Masyarakat dalam Menggunakan Smart Appliances

    Directory of Open Access Journals (Sweden)

    Diah Yuniarti

    2014-09-01

    Full Text Available Harga sumber energi yang semakin naik dari tahun ke tahun dan kemajuan teknologi telah mendorong perkembangan smart grid. Smart appliance merupakan salah satu komponen penting dalam smart grid. Penerapan smart appliance sejalan dengan kebijakan untuk mengurangi konsumsi energi, mengurangi emisi karbon dan penyediaan energi dari energi terbarukan. Penetrasi telepon bergerak turut memudahkan manajemen energi dan otomatisasi home appliance. Penelitian ini dilakukan untuk menganalisis minat masyarakat, yang merupakan aktor aktif dalam konsumsi dan manajemen energi di rumah tangga. Data penelitian dianalisis  dengan menggunakan metode structural equation modeling (SEM Hasil penelitian menunjukkan bahwa variabel enjoyment memiliki pengaruh yang signifikan terhadap minat dalam menggunakan smart appliance. Sedangkan, variabel compatibility ease of use, relative advantage dan image tidak memiliki pengaruh yang signifikan terhadap minat menggunakan smart appliance.

  10. Office management of obstructive sleep apnoea: appliances.

    Science.gov (United States)

    Johnson, Matthew D

    2015-08-01

    Oral appliances are becoming increasingly common in the treatment of obstructive sleep apnoea (OSA). They work by advancing the mandible and opening the pharynx. There are several types of devices available for use. Many patients intolerant to continuous positive airway pressure (CPAP) are using oral appliances for OSA. Oral appliances have been shown to improve polysomnography, quality of life and health measures associated with OSA. There is current work to better identify patients who are ideal candidates. Development of titratable devices and monitoring are optimizing usage. They have been compared with CPAP, with both showing improvement in OSA; however, CPAP remains superior overall. Oral appliances are becoming first-line therapy for mild and moderate OSA. They provide a meaningful alternative in severe OSA for patients unable to use CPAP. Device titration and usage monitoring are beginning to hone oral appliances as a therapeutic option.

  11. Load curve modelling of the residential segment electric power consumption applying a demand side energy management program; Modelagem da curva de carga das faixas de consumo de energia eletrica residencial a partir da aplicacao de um programa de gerenciamento de energia pelo lado da demanda

    Energy Technology Data Exchange (ETDEWEB)

    Rahde, Sergio Barbosa [Pontificia Univ. Catolica do Rio Grande do Sul, Porto Alegre (Brazil). Dept. de Engenharia Mecanica e Mecatronica]. E-mail: sergio@em.pucrs.br; Kaehler, Jose Wagner [Pontificia Univ. Catolica do Rio Grande do Sul, Porto Alegre (Brazil). Faculdade de Engenharia]. E-mail: kaehlerjw@pucrs.br

    2000-07-01

    The dissertation aims to offer a current vision on the use of electrical energy inside CEEE's newly defined area of operation. It also intends to propose different alternatives to set up a Demand Side Management (DSM) project to be carried out on the same market segment, through a Residential Load Management program. Starting from studies developed by DNAEE (the Brazilian federal government's agency for electrical energy), to establish the load curve characteristics, as well as from a research on electrical equipment ownership and electricity consumption habits, along with the contribution supplied by other utilities, especially in the US, an evaluation is offered, concerning several approaches to residential energy management, setting up conditions that simulate the residential segment's scenarios and their influence on the general system's load. (author)

  12. Effects of peak shaving technologies in the residential and commercial sector; Minsei bumon no fuka heijunka gijutsu no donyu koka

    Energy Technology Data Exchange (ETDEWEB)

    Nagata, Y. [Kyoto University, Kyoto (Japan); Takahashi, M.; Uchiyama, Y. [Central Research Institute of Electric Power Industry, Tokyo (Japan)

    1997-09-01

    This paper analyzes how much of the power demand could be reduced in the future by improving efficiencies of electric power utilizing appliances used in the residential and commercial sector. It discusses whether the reduction would lead to load leveling. Annual load rate in the power demand is continuing to decrease because of power demand increase in the residential and commercial sector, and increase in demand for air conditioning in summer. If a technology to improve electric appliance efficiency is proliferated to its maximum scope, the annual load rate in fiscal 2014 may be improved by 1.1 percent point. Since the improvement allows new power generation facility installation cost to be deferred, the power generation unit cost can be reduced by 0.11 yen per kwh. If a heat storage type air conditioning technology is proliferated to its maximum scope, the annual load rate in fiscal 2014 can be improved by 1.8 percent point, and the power generation cost may also be reduced. If the device efficiency improving technology and the heat storage type air conditioning technology are introduced to their maximum simultaneously, the annual load rate in fiscal 2014 can be improved by 2.5 percent point, and the power generation cost may also be reduced by 0.24 yen per kwh. If a promotion policy is taken on proliferation of a specific device efficiency improving technology having excellent economic performance by providing subsidy, the reduction amount of cumulative power generation expense will be much greater than the required subsidy amount. 10 refs., 9 figs., 22 tabs.

  13. Evaluation of safety management in an Appliances manufacturing company

    Directory of Open Access Journals (Sweden)

    F. Golbabaei

    2015-01-01

    Full Text Available Introduction: Prevention of accidents and work related diseases, are not allowed regardless of the safety of employees, customers, contractors and other persons. Assessment of individual safety management activities could reduce many losses. Present study aimed to evaluate the safety management of a household appliance manufacturing company.  .Material and Method: This study has done in a household appliance manufacturing company in Damavand city. Two questionnaires were firstly designed based on the weighted scores. The questionnaire 1 consisted of 4 indicators: Safety of machinery, Electrical safety, Risk assessment and Fire safety. Questionnaire 2 consisted of 11 sub indicators. Both questionnaires were completed by 30 HSE experts and supervisors. Reliability of questionnaires was based on cronbachs alpha coefficient. the safety status of each unit was determined and scored using information acquired by the questionnaires. Lastly, the safety of the entire company was determined.  .Result: Results showed that in safety management: the pressing and store house were in a good range of 66.66 and 60.12 points. Powder painting, enameling, laboratory were in a average range of 56.25, 55.92 and 54.15 points. Assembling and door storage were in a week range of 46.06 points.  .Conclusion: The findings showed that the safety status in the studied appliances company is in average range with 55.45 points. Therefore, it is recommended that the safety indicators should be improved for the betterment of the safety management in the company.

  14. Treatment of cooling appliances. Interrelations between environmental protection, resource conservation, and recovery rates

    International Nuclear Information System (INIS)

    Laner, David; Rechberger, Helmut

    2007-01-01

    The treatment of cooling appliances in Austria is primarily influenced by two factors. On the one hand is their changing composition and on the other hand the ordinance on Waste Prevention, Collection and Treatment of Waste Electrical and Electronic Equipment (WEEE ordinance), which stipulates a minimum recycling rate of 75% for cooling appliances. This paper investigates whether this recycling rate leads to optimal treatment practices for cooling appliances with respect to resource conservation and environmental protection. Two different treatment technologies which achieve recycling rates between 50-60% and 80-90%, respectively, are compared both for cooling appliances containing Chlorofluorocarbons (CFCs) and for appliances containing Volatile Organic Compounds (VOC). Materials and energy balances are developed for each model. To evaluate resource consumption, expenditures as well as savings of energy and materials are incorporated via the Cumulative Energy Demand (CED). In order to analyse the environmental impact of the different practices, balances for CFC, CO 2 , HF, HCl and solid residues are established. The results show that the treatment type aiming for a maximum of materials recycling contributes more to resource conservation than the other treatment type. But for CFC appliances the former is associated with substantial CFC emissions, which turn out to be most relevant when treating these appliances. Generally, it is found that the optimum recycling rate is a function of the composition of the appliance and the technologies applied, both in recycling and in primary production. A high recycling rate per se does not automatically result in an optimal solution with regard to resource conservation and environmental protection. (author)

  15. Estimating the energy and exergy utilization efficiencies for the residential-commercial sector: an application

    International Nuclear Information System (INIS)

    Utlu, Zafer; Hepbasli, Arif

    2006-01-01

    The main objectives in carrying out the present study are twofold, namely to estimate the energy and exergy utilization efficiencies for the residential-commercial sector and to compare those of various countries with each other. In this regard, Turkey is given as an illustrative example with its latest figures in 2002 since the data related to the following years are still being processed. Total energy and exergy inputs in this year are calculated to be 3257.20 and 3212.42 PJ, respectively. Annual fuel consumptions in space heating, water heating and cooking activities as well as electrical energy uses by appliances are also determined. The energy and exergy utilization efficiency values for the Turkish residential-commercial sector are obtained to be 55.58% and 9.33%, respectively. Besides this, Turkey's overall energy and exergy utilization efficiencies are found to be 46.02% and 24.99%, respectively. The present study clearly indicates the necessity of the planned studies toward increasing exergy utilization efficiencies in the sector studied

  16. High-Resolution Gas Metering and Nonintrusive Appliance Load Monitoring System

    Science.gov (United States)

    Tewolde, Mahder

    This thesis deals with design and implementation of a high-resolution metering system for residential natural gas meters. Detailed experimental measurements are performed on the meter to characterize and understand its measurement properties. Results from these experiments are used to develop a simple, fast and accurate technique to non-intrusively monitor the gas consumption of individual appliances in homes by resolving small amounts of gas usage. The technique is applied on an existing meter retrofitted with a module that includes a high-resolution encoder to collect gas flow data and a microprocessor to analyze and identify appliance load profiles. This approach provides a number of appealing features including low cost, easy installation and integration with automated meter reading (AMR) systems. The application of this method to residential gas meters currently deployed is also given. This is done by performing a load simulation on realistic gas loads with the aim of identifying the necessary parameters that minimize the cost and complexity of the mechanical encoder module. The primary benefits of the system are efficiency analysis, appliance health monitoring and real-time customer feedback of gas usage. Additional benefits of include the ability to detect very small leaks and theft. This system has the potential for wide scale market adoption.

  17. Adolescents and electricity consumption; Investigating sociodemographic, economic, and behavioural influences on electricity consumption in households

    International Nuclear Information System (INIS)

    Wallis, Hannah; Nachreiner, Malte; Matthies, Ellen

    2016-01-01

    With respect to changes in the energy systems of many countries, electricity consumption in households is an important topic. Extensive research has investigated the various determinants of electricity consumption. However, insights into how specific sociodemographic, behavioural, and attitudinal determinants influence residential electricity consumption are still scarce. In this study, we used hierarchical regression analysis to systematically investigate these determinants (including household engagement in electricity saving) along with a wide range of other measures in a sample of German households (N=763). Special attention was given to households with adolescents and children by analysing the influence of the number of adolescents on electricity consumption in a path model. Our results indicate that sociodemographic influences can be explained by the purchasing and use behaviours of residents. Our findings also suggest that the use of behavioural information provides a more detailed picture of the conditions of electricity consumption and thus allows for more appropriate policy planning. - Highlights: •We examined causal drivers of sociodemographic influences on electricity consumption •Sociodemographic influences can be explained by behaviour •Influence of adolescents is mediated by their purchases of IT appliances •It is necessary to also use behavioural information for policy planning

  18. Multi-kanban mechanism for appliance disassembly

    Science.gov (United States)

    Udomsawat, Gun; Gupta, Surendra M.

    2005-11-01

    The use of household appliances continues to rise every year. A significant number of End-Of-Life (EOL) appliances are generated because of the introduction of newer models that are more attractive, efficient and affordable. Others are, of course, generated when they become non-functional. Many regulations encourage recycling of EOL appliances to reduce the amount of waste sent to landfills. In addition, EOL appliances offer the appliance manufacturing and remanufacturing industries a source of less expensive raw materials and components. For this reason product recovery has become a subject of interest during the past decade. In this paper, we study the disassembly line for appliance disassembly. We discuss and incorporate some of the complications that are inherent in disassembly line including product arrival, demand arrival, inventory fluctuation and production control mechanisms. We show how to overcome such complications by implementing a multi-kanban system in the appliance disassembly line setting. The multi-kanban system (MKS) relies on dynamic routing of kanbans according to the state of the system. We investigate the multi-kanban mechanism using simulation and explore the effect of product mix on performance of the traditional push system (TPS) and MKS in terms of controlling the system's inventory while attempting to achieve a decent customer service level.

  19. Retrospective evaluation of appliance price trends

    International Nuclear Information System (INIS)

    Dale, Larry; Antinori, Camille; McNeil, Michael; McMahon, James E.; Sydny Fujita, K.

    2009-01-01

    Real prices of major appliances (refrigerators, dishwashers, heating and cooling equipment) have been falling since the late 1970s despite increases in appliance efficiency and other quality variables. This paper demonstrates that historic increases in efficiency over time, including those resulting from minimum efficiency standards, incur smaller price increases than were expected by the Department of Energy (DOE) forecasts made in conjunction with standards. This effect can be explained by technological innovation, which lowers the cost of efficiency, and by market changes contributing to lower markups and economies of scale in production of higher efficiency units. We reach four principal conclusions about appliance trends and retail price setting: 1.For the past several decades, the retail price of appliances has been steadily falling while efficiency has been increasing. 2.Past retail price predictions made by the DOE analyses of efficiency standards, assuming constant prices over time, have tended to overestimate retail prices. 3.The average incremental price to increase appliance efficiency has declined over time. DOE technical support documents have typically overestimated this incremental price and retail prices. 4.Changes in retail markups and economies of scale in production of more efficient appliances may have contributed to declines in prices of efficient appliances

  20. Using smart meter to monitor the energy consumption of home appliances

    International Nuclear Information System (INIS)

    Dong, M.; Xu, W.

    2010-01-01

    A smart meter provides the foundation for the smart grid, which represent the future electric system in terms of communications, sensors and automation to improve the flexibility, reliability and efficiency of power systems. Smart meters are installed at the utility-customer interface point to provide real-time power usage and price data to each electricity user. The purpose is to create customer awareness on electricity consumption and help users to conserve energy. Smart meters are being deployed throughout North America to replace most traditional meters. However, this paper discussed a major technical gap of the smart meter. Existing smart meters do not provide households with enough feedback needed to achieve effective energy saving. In order to support the energy conservation effort of a customer, the whole house energy data must be displayed on minute or second basis, and it must also be broken down into individual appliance levels. The data of an appliance's energy usage is the most useful information for users to modify their actions and conserve energy. This paper proposed to make the smart meter capable of reporting the overall consumption of a household, as well as monitoring how individual appliances use electricity. It presented a method on using different appliance signatures to identify appliances and make energy estimations on their respective consumptions. Paired with time-of-use or other real time pricing mechanisms, the method enables customers to save energy. This paper also demonstrated how to implement an algorithm on the smart meter platform. Future work will focus on making the algorithm more accurate and faster, and on integrating the smart meter with an appliance energy monitoring system. 21 refs., 6 tabs., 3 figs.

  1. 46 CFR 188.27-1 - Lifesaving appliances and arrangements.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Lifesaving appliances and arrangements. 188.27-1 Section... VESSELS GENERAL PROVISIONS Lifesaving Appliances and Arrangements § 188.27-1 Lifesaving appliances and arrangements. All lifesaving appliances and arrangements shall be in accordance with the requirements for...

  2. 46 CFR 195.06-1 - Lifesaving appliances and arrangements.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Lifesaving appliances and arrangements. 195.06-1 Section... VESSELS VESSEL CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Lifesaving Appliances and Arrangements § 195.06-1 Lifesaving appliances and arrangements. All lifesaving appliances and arrangements shall be...

  3. 46 CFR 90.27-1 - Lifesaving appliances and arrangements.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Lifesaving appliances and arrangements. 90.27-1 Section... VESSELS GENERAL PROVISIONS Lifesaving Appliances and Arrangements § 90.27-1 Lifesaving appliances and arrangements. All lifesaving appliances and arrangements must be in accordance with subchapter W (Lifesaving...

  4. 49 CFR 173.219 - Life-saving appliances.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Life-saving appliances. 173.219 Section 173.219... Life-saving appliances. (a) A life-saving appliance, self-inflating or non-self-inflating, containing small quantities of hazardous materials that are required as part of the life-saving appliance must...

  5. 46 CFR 70.28-1 - Lifesaving appliances and arrangements.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Lifesaving appliances and arrangements. 70.28-1 Section... PROVISIONS Lifesaving Appliances and Arrangements § 70.28-1 Lifesaving appliances and arrangements. All lifesaving appliances and arrangements on passenger vessels must be in accordance with subchapter W...

  6. Prediction of appliances energy use in smart homes

    International Nuclear Information System (INIS)

    Arghira, Nicoleta; Hawarah, Lamis; Ploix, Stéphane; Jacomino, Mireille

    2012-01-01

    This paper presents methods for prediction of energy consumption of different appliances in homes. The aim is to predict the next day electricity consumption for some services in homes. Historical data for a set of homes in France was used. Two basic predictors are tested and a stochastic based predictor is proposed. The performance of the predictors is studied and it shows that the proposed predictor gives better results than other approaches. Two processings are proposed to improve the performance of the predictor, segmentation and aggregation of data. Application results are provided.

  7. European Gas Appliances Directive and the Dutch Decree on Gas Appliances. Special section

    International Nuclear Information System (INIS)

    De Bruin, B.; Venhorst, T.; Van Tricht, A.

    1998-01-01

    The Gas Appliances Decree is the Dutch translation of the European Gas Appliances Directive. The Decree and the EU Directive contain substantial information, provided they will be read carefully. The EU Directive lays down general safety requirements for gas appliances. They serve as a practical tool for manufacturers and service engineers. In two articles, the Directive is explained, addressing uncertainties and answering important questions. 5 ills

  8. Characterizing Synergistic Water and Energy Efficiency at the Residential Scale Using a Cost Abatement Curve Approach

    Science.gov (United States)

    Stillwell, A. S.; Chini, C. M.; Schreiber, K. L.; Barker, Z. A.

    2015-12-01

    Energy and water are two increasingly correlated resources. Electricity generation at thermoelectric power plants requires cooling such that large water withdrawal and consumption rates are associated with electricity consumption. Drinking water and wastewater treatment require significant electricity inputs to clean, disinfect, and pump water. Due to this energy-water nexus, energy efficiency measures might be a cost-effective approach to reducing water use and water efficiency measures might support energy savings as well. This research characterizes the cost-effectiveness of different efficiency approaches in households by quantifying the direct and indirect water and energy savings that could be realized through efficiency measures, such as low-flow fixtures, energy and water efficient appliances, distributed generation, and solar water heating. Potential energy and water savings from these efficiency measures was analyzed in a product-lifetime adjusted economic model comparing efficiency measures to conventional counterparts. Results were displayed as cost abatement curves indicating the most economical measures to implement for a target reduction in water and/or energy consumption. These cost abatement curves are useful in supporting market innovation and investment in residential-scale efficiency.

  9. A segmented appliance for space closure followed by Invisalign and fixed appliances.

    Science.gov (United States)

    Uribe, Flavio; Cutrera, Alice; Nanda, Ravinda

    2011-01-01

    This case report describes the use of a segmented appliance for space closure prior to using Invisalign. The maxillary right canine was retracted into the extracted first premolar space with a sectional wire from the first molar to the canine with no visible brackets in the incisor region. The advantage of this technique is the ability to achieve better root and rotational control during space closure with a fixed appliance that also has limited visibility. A maxillary fixed appliance was used to refine the esthetics in the maxillary arch due to the limitations of the Invisalign appliance in achieving rotational and vertical movements.

  10. 76 FR 79057 - Appliance Labeling Rule

    Science.gov (United States)

    2011-12-21

    ... Part 305 Advertising, Energy conservation, Household appliances, Labeling, Reporting and recordkeeping... emitting diode (OLED) means a thin-film light- emitting device that typically consists of a series of...

  11. Research, Development and Demonstration of Micro-CHP Systems for Residential Applications - Phase I

    Energy Technology Data Exchange (ETDEWEB)

    Robert A. Zogg

    2011-03-14

    The objective of the Micro-CHP Phase I effort was to develop a conceptual design for a Micro-CHP system including: Defining market potential; Assessing proposed technology; Developing a proof-of-principle design; and Developing a commercialization strategy. TIAX LLC assembled a team to develop a Micro-CHP system that will provide electricity and heating. TIAX, the contractor and major cost-share provider, provided proven expertise in project management, prime-mover design and development, appliance development and commercialization, analysis of residential energy loads, technology assessment, and market analysis. Kohler Company, the manufacturing partner, is a highly regarded manufacturer of standby power systems and other residential products. Kohler provides a compellingly strong brand, along with the capabilities in product development, design, manufacture, distribution, sales, support, service, and marketing that only a manufacturer of Kohler's status can provide. GAMA, an association of appliance and equipment manufacturers, provided a critical understanding of appliance commercialization issues, including regulatory requirements, large-scale market acceptance issues, and commercialization strategies. The Propane Education & Research Council, a cost-share partner, provided cost share and aided in ensuring the fuel flexibility of the conceptual design. Micro-CHP systems being commercialized in Europe and Japan are generally designed to follow the household thermal load, and generate electricity opportunistically. In many cases, any excess electricity can be sold back to the grid (net metering). These products, however, are unlikely to meet the demands of the U.S. market. First, these products generally cannot provide emergency power when grid power is lost--a critical feature to market success in the U.S. Even those that can may have insufficient electric generation capacities to meet emergency needs for many U.S. homes. Second, the extent to which net

  12. Quality of Lab Appliances in Orthodontic Offices.

    Science.gov (United States)

    Pruzansky, D P; Park, J H

    Lab appliances are an integral part of orthodontics, from active treatment to retention. The quality and fit of an appliance can affect the treatment result and stability. This study aims to determine common points of failure in orthodontic appliances, and suggest methods to reduce this rate. A survey consisting of 23 questions was distributed to active members of the American Association of Orthodontists (AAO) via Survey Monkey. The most common appliance to need an adjustment was the wrap-around retainer, with the Hawley retainer as a close second. The least common appliance needing adjustment was the Essix/clear retainer. Respondents were asked which component of each appliance was most commonly responsible for an ill-fit. For Hawley and wrap-around retainers, clasps were the most common problem at 50%, whereas spring aligners had two components - clasps and labial bows, both at 38%. Ill-fitting Essix/clear retainers had gingival impingement (52%) closely followed by poor posterior seating (43%). Communication between the orthodontist and lab technician can be improved by establishing a quality assurance protocol for outgoing and incoming cases. The labial bow of Hawley's, wrap-arounds and spring aligners should be clearly demarcated on the casts. Impressions should be free of distortion and casts should be inspected for accuracy. Clear retainers and positioner should be trimmed to avoid gingival impingement. The type of clasp should be selected based on the anatomy of the teeth, and bands should be checked for accuracy of fit.

  13. Residential Energy Performance Metrics

    Directory of Open Access Journals (Sweden)

    Christopher Wright

    2010-06-01

    Full Text Available Techniques for residential energy monitoring are an emerging field that is currently drawing significant attention. This paper is a description of the current efforts to monitor and compare the performance of three solar powered homes built at Missouri University of Science and Technology. The homes are outfitted with an array of sensors and a data logger system to measure and record electricity production, system energy use, internal home temperature and humidity, hot water production, and exterior ambient conditions the houses are experiencing. Data is being collected to measure the performance of the houses, compare to energy modeling programs, design and develop cost effective sensor systems for energy monitoring, and produce a cost effective home control system.

  14. Electrification Opportunities in the Transportation Sector and Impact of Residential Charging

    Energy Technology Data Exchange (ETDEWEB)

    Muratori, Matteo [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2018-04-04

    This presentation provides an overview of electrification opportunities in the transportation sector and present results of a study assessing the impact of residential charging on residential power demand and electric power distribution infrastructure.

  15. Non-intrusive appliance load monitoring system based on a modern kWh-meter

    Energy Technology Data Exchange (ETDEWEB)

    Pihala, H. [VTT Energy, Espoo (Finland). Energy Systems

    1998-12-01

    Non-intrusive appliance load monitoring (NIALM) is a fairly new method to estimate load profiles of individual electric appliances in a small building, like a household, by monitoring the whole load at a single point with one recording device without sub-meters. Appliances have special electrical characteristics, the positive and negative active and reactive power changes during the time they are switched on or off. These changes are called events and are detected with a monitoring device called an event recorder. Different NIALM-concepts developed in Europe and in the United States are generally discussed. The NIALM-concept developed in this study is based on a 3-phase, power quality monitoring kWh-meter and unique load identification algorithms. This modern kWh-meter with a serial data bus to a laptop personal computer is used as die event recorder. The NIALM-concept of this presentation shows for the first time how a kWh-meter can be used at the same time for billing, power quality and appliance end-use monitoring. An essential part of the developed NIALM-system prototype is the software of load identification algorithms which runs in an off-line personal computer. These algorithms are able to identify, with a certain accuracy, both two-state and multi-state appliances. This prototype requires manual-setup in which the naming of appliances is performed. The results of the prototype NIALMS were verified in a large, single family detached house and they were compared to the results of other prototypes in France and the United States, although this comparison is difficult because of different supply systems, appliance stock and number of tested sites. Different applications of NIALM are discussed. Gathering of load research data, verification of DSM-programs, home automation, failure analysis of appliances and security surveillance of buildings are interesting areas of NIALM. Both utilities and customers can benefit from these applications. It is possible to

  16. Household electricity demand profiles

    DEFF Research Database (Denmark)

    Marszal, Anna Joanna; Heiselberg, Per Kvols; Larsen, Olena Kalyanova

    2016-01-01

    Highlights •A 1-min resolution household electricity load model is presented. •Model adapts a bottom-up approach with single appliance as the main building block. •Load profiles are used to analyse the flexibility potential of household appliances. •Load profiles can be applied in other domains, .......g. building energy simulations. •The demand level of houses with different number of occupants is well captured....

  17. Cephalometric effects of the Jones Jig appliance followed by fixed appliances in Class II malocclusion treatment.

    Science.gov (United States)

    Patel, Mayara Paim; Henriques, José Fernando Castanha; Freitas, Karina Maria Salvatore; Grec, Roberto Henrique da Costa

    2014-01-01

    The aim of this study was to cephalometrically assess the skeletal and dentoalveolar effects of Class II malocclusion treatment performed with the Jones Jig appliance followed by fixed appliances. The sample comprised 25 patients with Class II malocclusion treated with the Jones Jig appliance followed by fixed appliances, at a mean initial age of 12.90 years old. The mean time of the entire orthodontic treatment was 3.89 years. The distalization phase lasted for 0.85 years, after which the fixed appliance was used for 3.04 years. Cephalograms were used at initial (T1), post-distalization (T2) and final phases of treatment (T3). For intragroup comparison of the three phases evaluated, dependent ANOVA and Tukey tests were used. Jones Jig appliance did not interfere in the maxillary and mandibular component and did not change maxillomandibular relationship. Jones Jig appliance promoted distalization of first molars with anchorage loss, mesialization and significant extrusion of first and second premolars, as well as a significant increase in anterior face height at the end of treatment. The majority of adverse effects that occur during intraoral distalization are subsequently corrected during corrective mechanics. Buccal inclination and protrusion of mandibular incisors were identified. By the end of treatment, correction of overjet and overbite was observed. Jones Jig appliance promoted distalization of first molars with anchorage loss represented by significant mesial movement and extrusion of first and second premolars, in addition to a significant increase in anterior face height.

  18. Orthodontic appliance preferences of children and adolescents.

    Science.gov (United States)

    Walton, Daniel K; Fields, Henry W; Johnston, William M; Rosenstiel, Stephen F; Firestone, Allen R; Christensen, James C

    2010-12-01

    Although attractiveness and acceptability of orthodontic appliances have been rated by adults for themselves and for adolescents, children and adolescents have not provided any substantial data. The objective of this study was to evaluate preferences and acceptability of orthodontic appliances in children and adolescents. Images of orthodontic appliances previously captured and standardized were selected and incorporated into a computer-based survey. Additional images of shaped brackets and colored elastomeric ties, as well as discolored clear elastomeric ties, were captured and incorporated onto existing survey images with Photoshop (Adobe, San Jose, Calif). The survey displayed 12 orthodontic appliance variations to 139 children in 3 age groups: 9 to 11 years (n = 45), 12 to 14 years (n = 49), and 15 to 17 years (n = 45). The subjects rated each image for attractiveness and acceptability. All images were displayed and rated twice to assess rater reliability. Overall reliability ratings were r = 0.74 for attractiveness and k = 0.66 for acceptability. There were significant differences in bracket attractiveness and acceptability in each age group. The highest-rated appliances were clear aligners, twin brackets with colored ties, and shaped brackets with and without colored ties. Colored elastomeric ties improved attractiveness significantly over brackets without colored ties for children in the 12-to-14 year group. There was a tendency for older subjects to rate clear orthodontic appliances higher than did younger subjects. Ceramic brackets with discolored ties tended to be rated lower than ceramic brackets with new ties and scored lowest in acceptability and attractiveness in all age groups. Girls rated shaped brackets significantly higher than did boys. Children's preferences for orthodontic appliances differ by age and sex. Child and adolescent preferences differ from adult preferences. Copyright © 2010 American Association of Orthodontists. Published by Mosby

  19. Design, architecture and implementation of a residential energy box management tool in a SmartGrid

    International Nuclear Information System (INIS)

    Ioakimidis, Christos S.; Oliveira, Luís J.; Genikomsakis, Konstantinos N.; Dallas, Panagiotis I.

    2014-01-01

    This paper presents the EB (energy box) concept in the context of the V2G (vehicle-to-grid) technology to address the energy management needs of a modern residence, considering that the available infrastructure includes micro-renewable energy sources in the form of solar and wind power, the electricity loads consist of “smart” and conventional household appliances, while the battery of an EV (electric vehicle) plays the role of local storage. The problem is formulated as a multi-objective DSP (dynamic stochastic programming) model in order to maximize comfort and lifestyle preferences and minimize cost. Combining the DSP model that controls the EB operation with a neural network based approach for simulating the thermal model of a building, a set of scenarios are examined to exemplify the applicability of the proposed energy management tool. The EB is capable of working under real-time tariff and placing bids in electricity markets both as a stand-alone option and integrated in a SmartGrid paradigm, where a number of EBs are managed by an aggregator. The results obtained for the Portuguese tertiary electricity market indicate that this approach has the potential to compete as an ancillary service and sustain business with benefits for both the microgrid and residence occupants. - Highlights: • The energy box is a residential energy management tool in the context of V2G (vehicle-to-grid). • Multi-objective dynamic stochastic programming is used to model the energy box. • The energy box is working under real-time electricity pricing. • The proposed implementation is capable of placing bids in electricity markets. • The results indicate its potential to compete in the Portuguese tertiary market

  20. Demand curves of electric energy in domestic sector in two regions of Mexico; Curvas de demanda de energia electrica en sector domestico de dos regiones de Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Maqueda Zamora, Martin Roberto; Sanchez Viveros, Luis Agustin [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2011-07-01

    In this work, is presented the analysis of residential consumption, regarding the temperature of two areas and types of electrical appliances. A shape characteristic of the load of the electrical energy is obtained for two geographical areas in Mexico. The consumption information was obtained from measurements in residential consumers and from the Mexican Utility. It is also shown the demand profile of the main residential appliances, obtained from smart metering equipment to separate the residential users' load profiles. It is shown the effect of the different variables analyzed on the electrical power consumption, mainly the type of equipment, the geographical localization, the weather (temperature, humidity and vegetation type). With the results attained, the definition of effective energy-saving programs and its effectiveness can be obtained. [Spanish] En este trabajo se presenta el analisis del consumo residencial considerando la temperatura de las dos areas y tipos de aparatos electricos. Se obtiene una forma caracteristica de la carga de energia electrica de dos areas geograficas de Mexico. La informacion sobre el consumo se obtuvo de mediciones en consumidores residenciales y de una empresa electrica mexicana. Tambien se muestra el perfil de demanda de los principales aparatos residenciales, derivado de equipos de medicion inteligentes para separar los perfiles de carga de usuarios residenciales. Se muestra el efecto de diferentes variables analizadas en el consumo de energia electrica, principalmente el tipo de equipo, la localizacion geografica, el clima (temperatura, humedad y tipo de vegetacion). Con los resultados alcanzados pueden definirse programas de ahorro de energia efectivos y lograr implantarlos.

  1. Pellet fired appliances. Market survey. 7. rev. ed.; Pelletheizungen. Marktuebersicht

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-01-15

    The market survey under consideration reports on pellet central heating systems and pellet fired appliances. The main chapters of this market survey are concerned to: (1) Information on wood pellets and pellet fired appliances; (2) Information about the interpretation of the market survey; (3) Survey of all compared pellet fired appliances with respect to the nominal power; (4) Price lists of pellet fired appliances and pellet central heating systems; (5) Type sheets of the compared pellet fired appliances and pellet central heating systems. Finally, this brochure contains the addresses of the produces and distribution partners of pellet fired appliances and pellet central heating systems.

  2. Integrated Management of Residential Energy Resources

    Directory of Open Access Journals (Sweden)

    Antunes C. H.

    2012-10-01

    Full Text Available The increasing deployment of distributed generation systems based on renewables in the residential sector, the development of information and communication technologies and the expected evolution of traditional power systems towards smart grids are inducing changes in the passive role of end-users, namely with stimuli to change residential demand patterns. The residential user should be able to make decisions and efficiently manage his energy resources by taking advantages from his flexibility in load usage with the aim to minimize the electricity bill without depreciating the quality of energy services provided. The aim of this paper is characterizing electricity consumption in the residential sector and categorizing the different loads according to their typical usage, working cycles, technical constraints and possible degree of control. This categorization of end-use loads contributes to ascertain the availability of controllable loads to be managed as well as the different direct management actions that can be implemented. The ability to implement different management actions over diverse end-use load will increase the responsiveness of demand and potentially raises the willingness of end-users to accept such activities. The impacts on the aggregated national demand of large-scale dissemination of management systems that would help the end-user to make decisions regarding electricity consumption are predicted using a simulator that generates the aggregated residential sector electricity consumption under variable prices.

  3. Consumer knowledge and electricity consumption

    Energy Technology Data Exchange (ETDEWEB)

    Crawshaw, A J.E.; Williams, D I; Crawshaw, C M

    1985-12-01

    Householders in all-electric homes were asked to rank their electrical appliances in terms of annual running cost. By comparing this with an individually calculated correct order, an assessment of their knowledge was made. On this measure overall knowledge was good, but half the sample underestimated the running costs of key high-energy using appliances (space heating, hot-water, cooking). This specific lack of knowledge is critical, and was found to be correlated with higher bills. 16 references.

  4. Legal regulations in the field of electrotechnics. New regulations by the State and the professional associations concerning electrical appliances. Texts and explanations. Rechtsvorschriften im Bereich der Elektrotechnik. Neue staatliche und berufsgenossenschaftliche Rechtsvorschriften fuer elektrische Betriebsmittel. Texte und Erlaeuterungen

    Energy Technology Data Exchange (ETDEWEB)

    Noethlichs, M; Jeiter, W [Bundesministerium fuer Arbeit und Sozialordnung, Bonn-Duisdorf (Germany, F.R.); Stuerk, P [Hauptverband der Gewerblichen Berufsgenossenschaften e.V., Bonn (Germany, F.R.). Zentralstelle fuer Unfallverhuetung und Arbeitsmedizin

    1979-01-01

    Apart from the Verband Deutscher Elektrotechniker (VDE), also the State and the professional associations have discussed the hazards of electric power. Protection against these hazards is provided by a large number of legal regulations differing greatly in their form, text, addressers, and supervisory authorities. One point which all these regulations have in common is the statement that VDE regulations have the ultimate binding force for the safety of electrical plant and equipment. The regulations issued by the State and the professional regulations are rendered in full wording and discussed under the aspects of accident insurance, consumer protection and protection duties of producers and importers.

  5. Potential market-size for renewables in the residential sector of Pakistan

    International Nuclear Information System (INIS)

    Athar, G.R; Imtiaz, M.

    2005-01-01

    Renewable energy-sources can be used for meeting the energy-demand of various endues, like water-pumping for irrigation, process-heat for industries and desalination for potable water-supplies. However, the residential sector has the largest potential for renewable energy usage among all sectors of the economy. At present, the residential sector of Pakistan consumes some 26 million Tone of Oil Equivalent (MTOE) energy: with more than 6 MTOE in the form of commercial energy (electricity, natural gas, kerosene, LPG and coal) and about 20 MTOE in the form of non-commercial energy (wood, dung and crop-residues). Applied Systems Analysis Group (ASAG) has carried out a study to project the energy demand of Pakistan up to the year 2024-25, using an energy-demand model MAED. This model uses simulation technique to evaluate the energy-demand implications of a scenario, describing the assumed evolution of demographic parameters, economic activities, lifestyle of the population and technological improvements. The demographic targets of the Population-Policy of Pakistan and economic targets of Government of Pakistan have been adopted as the basis of our reference scenario. The study shows that the energy-demand of the residential sector will increase by a factor of 1.7, compared to the base-year 2001-2002. The residential sector will need 41. 9 MTOE energy, of which: (I) 5.9 MTOE (72.5 TWh) in the form of electricity to fulfill the energy-needs for lighting, cooling and other electric appliances, (II) 24.4 MTOE for cooking, (III) 5.7 MTOE for water heating, and (IV) 5.8 MTOE for space heating. In all these end-uses, renewable energy can make a contribution depending on the cost of energy, convenience of use and reliability of supply. Although, the government is vigorously pursuing a rural electrification program, a portion of residential sector, particularly in remote areas, will not be electrified even by 2024-25. The non-electrified houses will require 3 to 5 TWh of

  6. VOLTTRON-Based System for Providing Ancillary Services with Residential Building Loads

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Xin

    2016-07-01

    Ancillary services entail controlled modulation of building equipment to maintain a stable balance of generation and load in the power system. Ancillary services include frequency regulation and contingency reserves, whose acting time ranges from several seconds to several minutes. Many pilot studies have been implemented to use industrial loads to provide ancillary services, and some have explored services from commercial building loads or electric vehicle charging loads. Residential loads, such as space conditioning and water heating, represent a largely untapped resource for providing ancillary services. The residential building sector accounts for a significant fraction of the total electricity use in the United States. Many loads in residential buildings are flexible and could potentially be curtailed or shifted at the request of the grid. However, there are many barriers that prevent residential loads being widely used for ancillary services. One of the major technical barriers is the lack of communication capabilities between end-use devices and the grid. End-use devices need to be able to receive the automatic generation control (AGC) signal from the grid operator and supply certain types of telemetry to verify response. With the advance of consumer electronics, communication-enabled, or 'connected,' residential equipment has emerged to overcome the communication barrier. However, these end-use devices have introduced a new interoperability challenge due to the existence of numerous standards and communication protocols among different end devices. In this paper, we present a VOLTTRON-based system that overcomes these technical challenges and provides ancillary services with residential loads. VOLTTRON is an open-source control and sensing platform for building energy management, facilitating interoperability solutions for end devices. We have developed drivers to communicate and control different types of end devices through standard

  7. Development and Demonstration of the Open Automated Demand Response Standard for the Residential Sector

    Energy Technology Data Exchange (ETDEWEB)

    Herter, Karen; Rasin, Josh; Perry, Tim

    2009-11-30

    The goal of this study was to demonstrate a demand response system that can signal nearly every customer in all sectors through the integration of two widely available and non- proprietary communications technologies--Open Automated Demand Response (OpenADR) over lnternet protocol and Utility Messaging Channel (UMC) over FM radio. The outcomes of this project were as follows: (1) a software bridge to allow translation of pricing signals from OpenADR to UMC; and (2) a portable demonstration unit with an lnternet-connected notebook computer, a portfolio of DR-enabling technologies, and a model home. The demonstration unit provides visitors the opportunity to send electricity-pricing information over the lnternet (through OpenADR and UMC) and then watch as the model appliances and lighting respond to the signals. The integration of OpenADR and UMC completed and demonstrated in this study enables utilities to send hourly or sub-hourly electricity pricing information simultaneously to the residential, commercial and industrial sectors.

  8. FY 1999 project on the development of new industry support type international standards. Standardization for securing mutual connection among informative household electric appliances; 1999 nendo shinki sangyo shiengata kokusai hyojun kaihatsu jigyo seika hokokusho. Joho kaden kikikan no sogo setsuzokusei kakuho no tame no hyojunka

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    The R and D were conducted with the aim of the international standardization for securing mutual connection among informative household electric appliances, and the FY 1999 results were summarized. In FY 1999, the following were conducted: trial manufacture (for mass production) and evaluation of wide band POF (plastic optical fiber), trial manufacture and evaluation of home use small connector, and trial manufacture and evaluation of optical transceiver module. Various data required for the targeted standardization (transmission band: S400 or more, transmission distance: 100m) were obtained. In the next fiscal year, tests to demonstrate validity/reliability of the data are conducted so that the standards to be accepted as an international standard can be established. In the study of strategies of international standardization, the contents of the standards proposed were discussed, and activities of IEC/TC100 (multi-media) and the related TC were investigated. Early in the next fiscal year, the TC to be proposed is fixed, and international proposing activities are started such as the introduction of the standardization for this R and D to the organizations and persons concerned overseas. (NEDO)

  9. Residential energy use in one-family households with natural gas provision in a city of the Patagonian Andean region

    International Nuclear Information System (INIS)

    Gonzalez, A.D.; Carlsson-Kanyama, A.; Crivelli, E.S.; Gortari, S.

    2007-01-01

    Residential energy use was studied in one-family houses in the city of Bariloche, in the Patagonian Andean region of Argentina. A survey was conducted of households connected to the natural gas network to correlate use of gas, living area and number of inhabitants per house. The annual average consumption of gas was found to be 169 GJ, and consumption of electricity 8 GJ. This total energy use per household per year is almost double the average value reported for Stockholm, Sweden, although both locations have similar heating requirements. The difference was mainly due to heating energy consumption per unit living space, which in Bariloche was 1530 MJ/m 2 per year, while in Stockholm the average is around 570 MJ/m 2 per year. The high energy consumption in Bariloche is explained primarily by the construction characteristics of the buildings, and secondarily by the efficiency of the heating devices used. We were able to conclude that subsidies on natural gas tariffs given to the residential sector do not promote a rational use of the resource. Furthermore, almost 40% of the population (mostly households in poverty) are not connected to the subsidised gas resource, but pay prices for alternative fuels that are between 10- and 15 times higher. Policies to improve buildings and appliances would reduce emissions and make access to energy more equitable

  10. Design and optimization of zero-energy-consumption based solar energy residential building systems

    Science.gov (United States)

    Zheng, D. L.; Yu, L. J.; Tan, H. W.

    2017-11-01

    Energy consumption of residential buildings has grown fast in recent years, thus raising a challenge on zero energy residential building (ZERB) systems, which aim at substantially reducing energy consumption of residential buildings. Thus, how to facilitate ZERB has become a hot but difficult topic. In the paper, we put forward the overall design principle of ZERB based on analysis of the systems’ energy demand. In particular, the architecture for both schematic design and passive technology is optimized and both energy simulation analysis and energy balancing analysis are implemented, followed by committing the selection of high-efficiency appliance and renewable energy sources for ZERB residential building. In addition, Chinese classical residential building has been investigated in the proposed case, in which several critical aspects such as building optimization, passive design, PV panel and HVAC system integrated with solar water heater, Phase change materials, natural ventilation, etc., have been taken into consideration.

  11. Colostomies and the use of colostomy appliances.

    Science.gov (United States)

    Cronin, Elaine

    The surgical formation of a colostomy is indicated as part of the treatment of various conditions, primarily colon cancer, requiring the patient (ostomist) to wear a colostomy pouch. Today's stoma appliances bear no resemblance to those worn three or four decades ago when colostomy, ileostomy and urostomy bags were made entirely from rubber. The patient, who would have two to three bags in circulation at a time, would interchange them allowing for the washing and drying of the previous one, thus minimizing odour and potential perishing of the rubber. The design of these appliances was simple, but they were large and bulky and the outlet resembled that of a hot-water bottle stopper or a cap from an old soda bottle that required the insertion of coinage (2p) to open it. This article explores the range of colostomy appliances and management options available to the nurse when caring for patients with a colostomy.

  12. Extra-oral Appliances in Orthodontic Treatment.

    Science.gov (United States)

    Almuzian, Mohammed; Alharbi, Fahad; McIntyre, Grant

    2016-01-01

    Extra-oral appliances are used in orthodontics to apply forces to the jaws, dentition or both and the popularity of these appliances is cyclical. Although the use of retraction headgear for the management of Class II malocclusion has declined over the last 20 years with the refinement of non-compliance approaches, including temporary anchorage devices, headgear still has a useful role in orthodontics. The use of protraction headgear has increased as more evidence of its effectiveness for the treatment of Class lIl malocclusion has become available. This paper describes the mechanics and contemporary uses of headgear in orthodontics for primary care dentists and specialist orthodontists. CPD/CLINICAL RELEVANCE: Extra-oral appliances have specific uses in orthodontic biomechanics. Clinicians using retraction headgear and protraction headgear should be familiar with their clinical indications, the potential problems and how these can be avoided.

  13. Cost-benefit analysis: introducing energy efficient and renewable energy appliances in Lebanese households

    Energy Technology Data Exchange (ETDEWEB)

    Ruble, Isabella [American University of Beirut, Department of Economics (Lebanon)], E-mail: economics.ir@gmail.com

    2011-07-01

    In Lebanon, neglect of the electricity sector has led to a serious shortage in installed capacity. Recently, the government of Lebanon declared its intention to raise the share of renewable energy (RE) year by year in order to reduce energy consumption. This paper gave a cost-benefit analysis and reviewed the replacement of five major traditional household appliances with their energy efficient (EE) or renewable energy counterparts. This initiative would mostly be felt in three main areas: electricity consumption, consumer costs, and government expenditure. There is a strong possibility that the electricity demand of the 1.2 million Lebanese households can be reduced by introduction of these EE household appliances. Benefits would also accrue to the government in the form of avoided subsidies and reduced need for installed capacity. This paper finds that the benefits to be expected from these policy recommendations largely outweigh the costs.

  14. A comparison of four methods to evaluate the effect of a utility residential air-conditioner load control program on peak electricity use

    Energy Technology Data Exchange (ETDEWEB)

    Newsham, Guy R., E-mail: guy.newsham@nrc-cnrc.gc.ca [National Research Council Canada-Institute for Research in Construction, Building M24, 1200 Montreal Road, Ottawa, Ontario, K1A 0R6 (Canada); Birt, Benjamin J. [National Research Council Canada-Institute for Research in Construction, Building M24, 1200 Montreal Road, Ottawa, Ontario, K1A 0R6 (Canada); Rowlands, Ian H. [University of Waterloo, Ontario (Canada)

    2011-10-15

    We analyzed the peak load reductions due to a residential direct load control program for air-conditioners in southern Ontario in 2008. In this program, participant thermostats were increased by 2 deg. C for four hours on five event days. We used hourly, whole-house data for 195 participant households and 268 non-participant households, and four different methods of analysis ranging from simple spreadsheet-based comparisons of average loads on event days, to complex time-series regression. Average peak load reductions were 0.2-0.9 kWh/h per household, or 10-35%. However, there were large differences between event days and across event hours, and in results for the same event day/hour, with different analysis methods. There was also a wide range of load reductions between individual households, and only a minority of households contributed to any given event. Policy makers should be aware of how the choice of an analysis method may affect decisions regarding which demand-side management programs to support, and how they might be incentivized. We recommend greater use of time-series methods, although it might take time to become comfortable with their complexity. Further investigation of what type of households contribute most to aggregate load reductions would also help policy makers better target programs. - Highlights: > We analyzed peak load reductions due to residential a/c load control. > We used four methods, ranging from simple comparisons to time-series regression. > Average peak load reductions were 0.2-0.9 kW per household, varying by method. > We recommend a move towards time-series regression for future studies. > A minority of participant households contributed to a given load control event.

  15. Development of Residential SOFC Cogeneration System

    Science.gov (United States)

    Ono, Takashi; Miyachi, Itaru; Suzuki, Minoru; Higaki, Katsuki

    2011-06-01

    Since 2001 Kyocera has been developing 1kW class Solid Oxide Fuel Cell (SOFC) for power generation system. We have developed a cell, stack, module and system. Since 2004, Kyocera and Osaka Gas Co., Ltd. have been developed SOFC residential co-generation system. From 2007, we took part in the "Demonstrative Research on Solid Oxide Fuel Cells" Project conducted by New Energy Foundation (NEF). Total 57 units of 0.7kW class SOFC cogeneration systems had been installed at residential houses. In spite of residential small power demand, the actual electric efficiency was about 40%(netAC,LHV), and high CO2 reduction performance was achieved by these systems. Hereafter, new joint development, Osaka Gas, Toyota Motors, Kyocera and Aisin Seiki, aims early commercialization of residential SOFC CHP system.

  16. Development of Residential SOFC Cogeneration System

    International Nuclear Information System (INIS)

    Ono, Takashi; Miyachi, Itaru; Suzuki, Minoru; Higaki, Katsuki

    2011-01-01

    Since 2001 Kyocera has been developing 1kW class Solid Oxide Fuel Cell (SOFC) for power generation system. We have developed a cell, stack, module and system. Since 2004, Kyocera and Osaka Gas Co., Ltd. have been developed SOFC residential co-generation system. From 2007, we took part in the 'Demonstrative Research on Solid Oxide Fuel Cells' Project conducted by New Energy Foundation (NEF). Total 57 units of 0.7kW class SOFC cogeneration systems had been installed at residential houses. In spite of residential small power demand, the actual electric efficiency was about 40%(netAC,LHV), and high CO2 reduction performance was achieved by these systems. Hereafter, new joint development, Osaka Gas, Toyota Motors, Kyocera and Aisin Seiki, aims early commercialization of residential SOFC CHP system.

  17. 49 CFR 236.308 - Mechanical or electric locking or electric circuits; requisites.

    Science.gov (United States)

    2010-10-01

    ..., AND APPLIANCES Interlocking Standards § 236.308 Mechanical or electric locking or electric circuits; requisites. Mechanical or electric locking or electric circuits shall be installed to prevent signals from... 49 Transportation 4 2010-10-01 2010-10-01 false Mechanical or electric locking or electric...

  18. Comparison of emissions from selected commercial kitchen appliances and food products

    Energy Technology Data Exchange (ETDEWEB)

    Kuehn, T.H.; Gerstler, W.D.; Pui, D.Y.H.; Ramsey, J.W.

    1999-07-01

    Effluents have been measured from various grease-producing cooking processes in an attempt to quantify the emissions that enter typical commercial kitchen exhaust hoods. The appliances tested include gas and electric versions of single-sided griddles, open-vat deep fat fryers, under-fired broilers, full size convection ovens, and six burner ranges. Food products include hamburger, chicken breast, fries, sausage pizza, and a spaghetti meal. Emission data were obtained for particles, grease vapor, CO, CO{sub 2}, NO{sub x}, and hydrocarbons. Velocity and temperature fields were measured in the plume above each appliance. Results show that a large fraction of the grease emission is typically in vapor form. The broilers emit significantly more particles less than 2.5 {micro}m in size (PM 2.5) than the other appliances tested. Combustion by-products were measured for all gas appliances. Both the gas and electric broilers emitted significant amounts of CO when hamburgers were cooked. Aromatic hydrocarbon concentrations were below detectable limits in all tests.

  19. Gas appliances in the domestic market - legal basis and questioning concerning the Directive for Gas Appliances

    International Nuclear Information System (INIS)

    Rienen, W. van

    1994-01-01

    Four years after the Directive for Gas Appliances has been passed by the European Community it shows the first effects on the market. Gas appliances bearing an CE label can prove that the EC-standardised demands are observed. Thus it can be demanded from every member state by law not to hinder a launch on the market and the initiation. The directive also effects the demands for national environmental protection. A new DVGW (Deutscher Verein des Gas und Wasserfaches e.V.) quality label for gas appliances is going to certify the observance of a quality level which exceeds the minimum EC level. (orig.) [de

  20. Heterogeneous Collaborative Sensor Network for Electrical Management of an Automated House with PV Energy

    Directory of Open Access Journals (Sweden)

    Javier Jiménez-Leube

    2011-12-01

    Full Text Available In this paper we present a heterogeneous collaborative sensor network for electrical management in the residential sector. Improving demand-side management is very important in distributed energy generation applications. Sensing and control are the foundations of the “Smart Grid” which is the future of large-scale energy management. The system presented in this paper has been developed on a self-sufficient solar house called “MagicBox” equipped with grid connection, PV generation, lead-acid batteries, controllable appliances and smart metering. Therefore, there is a large number of energy variables to be monitored that allow us to precisely manage the energy performance of the house by means of collaborative sensors. The experimental results, performed on a real house, demonstrate the feasibility of the proposed collaborative system to reduce the consumption of electrical power and to increase energy efficiency.

  1. Heterogeneous collaborative sensor network for electrical management of an automated house with PV energy.

    Science.gov (United States)

    Castillo-Cagigal, Manuel; Matallanas, Eduardo; Gutiérrez, Alvaro; Monasterio-Huelin, Félix; Caamaño-Martín, Estefaná; Masa-Bote, Daniel; Jiménez-Leube, Javier

    2011-01-01

    In this paper we present a heterogeneous collaborative sensor network for electrical management in the residential sector. Improving demand-side management is very important in distributed energy generation applications. Sensing and control are the foundations of the "Smart Grid" which is the future of large-scale energy management. The system presented in this paper has been developed on a self-sufficient solar house called "MagicBox" equipped with grid connection, PV generation, lead-acid batteries, controllable appliances and smart metering. Therefore, there is a large number of energy variables to be monitored that allow us to precisely manage the energy performance of the house by means of collaborative sensors. The experimental results, performed on a real house, demonstrate the feasibility of the proposed collaborative system to reduce the consumption of electrical power and to increase energy efficiency.

  2. Heterogeneous Collaborative Sensor Network for Electrical Management of an Automated House with PV Energy

    Science.gov (United States)

    Castillo-Cagigal, Manuel; Matallanas, Eduardo; Gutiérrez, Álvaro; Monasterio-Huelin, Félix; Caamaño-Martín, Estefaná; Masa-Bote, Daniel; Jiménez-Leube, Javier

    2011-01-01

    In this paper we present a heterogeneous collaborative sensor network for electrical management in the residential sector. Improving demand-side management is very important in distributed energy generation applications. Sensing and control are the foundations of the “Smart Grid” which is the future of large-scale energy management. The system presented in this paper has been developed on a self-sufficient solar house called “MagicBox” equipped with grid connection, PV generation, lead-acid batteries, controllable appliances and smart metering. Therefore, there is a large number of energy variables to be monitored that allow us to precisely manage the energy performance of the house by means of collaborative sensors. The experimental results, performed on a real house, demonstrate the feasibility of the proposed collaborative system to reduce the consumption of electrical power and to increase energy efficiency. PMID:22247680

  3. Equipment and appliances for underwater operations. Pt. 2

    International Nuclear Information System (INIS)

    Krueger, P.

    1976-01-01

    The 6/75 edition of 'mt' reported on the 'ARGE underwater appliances' and the study on 'design development of appliances and equipment for underwater use' in a brief summary. One of these designs, the 'unmanned DSWS underwater appliance' was described in detail. The present article describes three further design developments mentioned in the above study and which are based on unmanned appliances connected to the mother-ship. These designs were developed by Preussag-Meerestechnik. (orig.) [de

  4. Hybrid LSA-ANN Based Home Energy Management Scheduling Controller for Residential Demand Response Strategy

    Directory of Open Access Journals (Sweden)

    Maytham S. Ahmed

    2016-09-01

    Full Text Available Demand response (DR program can shift peak time load to off-peak time, thereby reducing greenhouse gas emissions and allowing energy conservation. In this study, the home energy management scheduling controller of the residential DR strategy is proposed using the hybrid lightning search algorithm (LSA-based artificial neural network (ANN to predict the optimal ON/OFF status for home appliances. Consequently, the scheduled operation of several appliances is improved in terms of cost savings. In the proposed approach, a set of the most common residential appliances are modeled, and their activation is controlled by the hybrid LSA-ANN based home energy management scheduling controller. Four appliances, namely, air conditioner, water heater, refrigerator, and washing machine (WM, are developed by Matlab/Simulink according to customer preferences and priority of appliances. The ANN controller has to be tuned properly using suitable learning rate value and number of nodes in the hidden layers to schedule the appliances optimally. Given that finding proper ANN tuning parameters is difficult, the LSA optimization is hybridized with ANN to improve the ANN performances by selecting the optimum values of neurons in each hidden layer and learning rate. Therefore, the ON/OFF estimation accuracy by ANN can be improved. Results of the hybrid LSA-ANN are compared with those of hybrid particle swarm optimization (PSO based ANN to validate the developed algorithm. Results show that the hybrid LSA-ANN outperforms the hybrid PSO based ANN. The proposed scheduling algorithm can significantly reduce the peak-hour energy consumption during the DR event by up to 9.7138% considering four appliances per 7-h period.

  5. 46 CFR 78.17-5 - Valves and closing appliances.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Valves and closing appliances. 78.17-5 Section 78.17-5..., Drills, and Inspections § 78.17-5 Valves and closing appliances. (a) It shall be the duty of the master to see that all valves, including cross connecting valves where fitted, and other appliances such as...

  6. 46 CFR 109.209 - Appliances for watertight integrity.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Appliances for watertight integrity. 109.209 Section 109... OPERATIONS Tests, Drills, and Inspections § 109.209 Appliances for watertight integrity. (a) Before getting underway, the master or person in charge shall insure that each appliance for watertight integrity is...

  7. 46 CFR 78.47-38 - Valves and closing appliances.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Valves and closing appliances. 78.47-38 Section 78.47-38... Fire and Emergency Equipment, Etc. § 78.47-38 Valves and closing appliances. (a) All valves and closing appliances, or other mechanisms which may be required to be operated for damage control purposes in case of...

  8. Load Characterization for small domestic appliances and electronics

    NARCIS (Netherlands)

    Van der Sluis, P.

    2009-01-01

    In this report, the energy consumption of small domestic loads has been analysed. To make the around 100 types of appliances considereda bit manageable, the appliances were categorized into several groups. The possibilities for time-shifting of the energy use of these small appliances was

  9. 38 CFR 17.150 - Prosthetic and similar appliances.

    Science.gov (United States)

    2010-07-01

    ... appliances. 17.150 Section 17.150 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS MEDICAL Prosthetic, Sensory, and Rehabilitative Aids § 17.150 Prosthetic and similar appliances... appliances including invalid lifts and therapeutic and rehabilitative devices, and special clothing made...

  10. 46 CFR 199.70 - Personal lifesaving appliances.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Personal lifesaving appliances. 199.70 Section 199.70 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) LIFESAVING APPLIANCES AND ARRANGEMENTS... appliances. (a) Lifebuoys. Each vessel must carry lifebuoys approved under approval series 160.150 as follows...

  11. 42 CFR 409.14 - Supplies, appliances, and equipment.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Supplies, appliances, and equipment. 409.14 Section... Hospital Services § 409.14 Supplies, appliances, and equipment. (a) Except as specified in paragraph (b) of this section, Medicare pays for supplies, appliances, and equipment as inpatient hospital or inpatient...

  12. Modeling of GE Appliances in GridLAB-D: Peak Demand Reduction

    Energy Technology Data Exchange (ETDEWEB)

    Fuller, Jason C.; Vyakaranam, Bharat GNVSR; Prakash Kumar, Nirupama; Leistritz, Sean M.; Parker, Graham B.

    2012-04-29

    The widespread adoption of demand response enabled appliances and thermostats can result in significant reduction to peak electrical demand and provide potential grid stabilization benefits. GE has developed a line of appliances that will have the capability of offering several levels of demand reduction actions based on information from the utility grid, often in the form of price. However due to a number of factors, including the number of demand response enabled appliances available at any given time, the reduction of diversity factor due to the synchronizing control signal, and the percentage of consumers who may override the utility signal, it can be difficult to predict the aggregate response of a large number of residences. The effects of these behaviors can be modeled and simulated in open-source software, GridLAB-D, including evaluation of appliance controls, improvement to current algorithms, and development of aggregate control methodologies. This report is the first in a series of three reports describing the potential of GE's demand response enabled appliances to provide benefits to the utility grid. The first report will describe the modeling methodology used to represent the GE appliances in the GridLAB-D simulation environment and the estimated potential for peak demand reduction at various deployment levels. The second and third reports will explore the potential of aggregated group actions to positively impact grid stability, including frequency and voltage regulation and spinning reserves, and the impacts on distribution feeder voltage regulation, including mitigation of fluctuations caused by high penetration of photovoltaic distributed generation and the effects on volt-var control schemes.

  13. On the necessity of improving the environmental impacts of furniture and appliances in net-zero energy buildings.

    Science.gov (United States)

    Hoxha, Endrit; Jusselme, Thomas

    2017-10-15

    There is now clear evidence regarding the extensive use of furniture and appliances in daily human life, but there is less evidence of their impact on the environment. Responding to this gap in knowledge, this study focuses on an assessment of the environmental impacts of furniture and appliances as used in highly energy efficient buildings. Their primary energy, non-renewable energy and global warming potential indicators have been assessed by extending the boundaries of the Life Cycle Assessment (LCA) study beyond the building itself. In conclusion, we found that furniture and appliances were responsible for around 30% of greenhouse gas emissions and non-renewable energy consumption and 15% of primary energy consumption comparing to the overall impacts of the building. Since embodied impacts represent the largest values, the process for labelling the appliances' energy efficiency should encompass a life-cycle point of view, not just a usage point of view as the case currently. Among office appliances, computer equipment was ranked as the highest impacting element, especially laptops and monitors. As for domestic appliances, refrigerators and electric ovens had the biggest impacts. Concerning furniture, the greatest impacts were from office and kitchen cabinets. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Accelerated electricity conservation in Juneau, Alaska: A study of household activities that reduced demand 25%

    International Nuclear Information System (INIS)

    Leighty, Wayne; Meier, Alan

    2011-01-01

    An avalanche destroyed the main hydroelectric transmission line to Juneau, Alaska in April, 2008. Diesel-generated electricity was substituted, causing electricity prices to increase 500% for 45 days. Electricity demand fell by 25% during the supply disruption. Most of the reduction occurred before the higher rates were implemented. Some conservation - about 8% of historic consumption - persisted after the transmission line was repaired and prices returned to normal. Consumers reduced energy use through a combination of new habits and technical improvements. A survey of residential consumers indicated that the average household undertook 10 conservation actions, with major changes in lighting, space heating, fuel switching, and water and appliance use. We propose a method for prioritizing conservation actions for promotion according to their impact in electricity savings (as a function of popularity, effectiveness, and persistence) and a dynamic framework for electricity use before, during, and after a supply disruption (i.e., both the magnitude and rates of change in electricity conservation). - Research highlights: → An electricity supply disruption caused prices to increase 500% for 45 days. → Electricity conservation of 25% occurred in a matter of days. → Electricity conservation of 8% persisted after the supply disruption was repaired. → Conservation occurred through behavior change and technology adoption. → The disruption induced consumers to try new behaviors that became new habits.

  15. Energetic, exergetic and economic analysis of an innovative Solar CombiSystem (SCS) producing thermal and electric energies: Application in residential and tertiary households

    International Nuclear Information System (INIS)

    Hazami, Majdi; Mehdaoui, Farah; Naili, Nabiha; Noro, Marco; Lazzarin, Renato; Guizani, AmenAllah

    2017-01-01

    Highlights: • The present work studies the potential of using innovative SCS in Tunisia. • In cold months the SCS provide about 50–75% of the total exergy provides. • The SCS produces between 70–150% of electric energy needs. • The SCS payback period (Pb) based on electric water heater was 10.2 years. • The SCS payback period (Pb) based on gas/gas town was about and 8.7 years. - Abstract: The endeavor of this paper is to study of the potential offered by the expenditure of an innovative Solar CombiSystem, SCS, used for the space heating load, the domestic hot water supply and the electric energy production. The investigation achieved in this work was based on an experimental and a simulation studies. A TRNSYS simulation program was achieved in order to evaluate the SCS monthly/annual thermal and electric performances. It was found that the proposed SCS covered between 20 and 45% of the SH energy needs by considering only solar energy. The result shows also that the SCS provided from 40 to 70% of the total DHW needs. It was also found that the SCS electric production ranged between 32 and 225 MJ/m 2 with a gain factor varying between 49 and 125%. An economic appraisal was also achieved to appraise the SCS feasibility. The results of the economic analysis show that the annual energy saved (ARE) and the payback period (Pb) based on electric water heater were respectively equal to 7618.3 kW h/year and 10.2 years. It was found that ARE and Pb based on gas/gas town were about 5825 m 3 and 8.7 years, respectively. The results of the economic analysis shows that the adoption of the SCS saves about 48% of electric energy and about 46% of gas/gas town kept back by the conventional system.

  16. Mandibular advancement appliance for obstructive sleep apnoea

    DEFF Research Database (Denmark)

    Petri, Niels; Svanholt, Palle; Solow, Beni

    2008-01-01

    The aim of this trial was to evaluate the efficacy of a mandibular advancement appliance (MAA) for obstructive sleep apnoea (OSA). Ninety-three patients with OSA and a mean apnoea-hypopnoea index (AHI) of 34.7 were centrally randomised into three, parallel groups: (a) MAA; (b) mandibular non...

  17. A modified, lingually supported cantilevered Herbst appliance.

    Science.gov (United States)

    Snodgrass, D

    1996-01-01

    This new, fixed-functional appliance/Herbst/Bioprogressive system is designed for patient comfort and mandatory compliance. It also combines the positive clinical effects of four fixed-functional systems. It allows rapid palatal expansion of the upper arch, alveolar uprighting of the lower arch, upper and lower incisor alignment, and sagittal correction of Class II malocclusions to occur simultaneously with one appliance fixed in both arches. It is indicated for use in growing patients with skeletal Class II malocclusions. The ideal timing for treatment is the late mixed dentition. Being able to remove the appliance after one year with the upper second bicuspids erupting slightly Class III so the clinician can immediately begin fixed finishing mechanics would be ideal. This new Herbst design will reduce the frequency of orthognathic surgery and upper bicuspid extraction to camouflage Class II malocclusions. At the same time, it gives total control to the clinician in treating some more difficult, non-compliant patients. Fixed-functional appliances, which improve treatment efficiency and treatment results and provide for patient comfort, while at the same time give the treating clinician almost total control of the three planes of facial growth will open new doors for orthodontic treatment and research in the next century.

  18. Custom Made Pressure Appliance for Presurgical Sustained ...

    African Journals Online (AJOL)

    was done to match the color of the appliance with that of the adjoining skin to make ... of the surface of the swelling with the gap between the two ... Figure 1: Preoperative view of keloid .... “multi model” approach for treating ear keloids. Indian J ...

  19. Procedures for Calculating Residential Dehumidification Loads

    Energy Technology Data Exchange (ETDEWEB)

    Winkler, Jon [National Renewable Energy Lab. (NREL), Golden, CO (United States); Booten, Chuck [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-06-01

    Residential building codes and voluntary labeling programs are continually increasing the energy efficiency requirements of residential buildings. Improving a building's thermal enclosure and installing energy-efficient appliances and lighting can result in significant reductions in sensible cooling loads leading to smaller air conditioners and shorter cooling seasons. However due to fresh air ventilation requirements and internal gains, latent cooling loads are not reduced by the same proportion. Thus, it's becoming more challenging for conventional cooling equipment to control indoor humidity at part-load cooling conditions and using conventional cooling equipment in a non-conventional building poses the potential risk of high indoor humidity. The objective of this project was to investigate the impact the chosen design condition has on the calculated part-load cooling moisture load, and compare calculated moisture loads and the required dehumidification capacity to whole-building simulations. Procedures for sizing whole-house supplemental dehumidification equipment have yet to be formalized; however minor modifications to current Air-Conditioner Contractors of America (ACCA) Manual J load calculation procedures are appropriate for calculating residential part-load cooling moisture loads. Though ASHRAE 1% DP design conditions are commonly used to determine the dehumidification requirements for commercial buildings, an appropriate DP design condition for residential buildings has not been investigated. Two methods for sizing supplemental dehumidification equipment were developed and tested. The first method closely followed Manual J cooling load calculations; whereas the second method made more conservative assumptions impacting both sensible and latent loads.

  20. Electricity

    CERN Document Server

    Basford, Leslie

    2013-01-01

    Electricity Made Simple covers the fundamental principles underlying every aspect of electricity. The book discusses current; resistance including its measurement, Kirchhoff's laws, and resistors; electroheat, electromagnetics and electrochemistry; and the motor and generator effects of electromagnetic forces. The text also describes alternating current, circuits and inductors, alternating current circuits, and a.c. generators and motors. Other methods of generating electromagnetic forces are also considered. The book is useful for electrical engineering students.

  1. Mobile based Appliances switching using Bluetooth

    Science.gov (United States)

    Gupta, Sureshchandra J., Dr; Desai, Kalp; Gaikawad, Deepak; Pawar, Vijay N.; Gangal, Devendranath R.

    2008-04-01

    How many times do you have to get up from your desk to switch on your Air conditioner or fan when you are completely into your table work? How many times do you feel lazy to get off your comfort to switch on/off your home appliances in different rooms? How much energy do you lose in a day for operating your appliances? The solution is either a large amount of manual work—or the idea that is presented over here: APP-CON (APP-CON stands for appliances control). Here the ordinary cell phone with bluetooth capability acts as remote designed in such a manner that it acts as a helping hand to human by reducing its manual work and therefore saving human energy. The cell phone control of APP-CON units lets you access many of your home appliances situated in different rooms by using just a single remote from distance. Electronics hobbyists would love to make such a remote control themselves. But they find it difficult due to complex circuitry rather than the high cost because of using a number of frequency counting techniques and decade counters. The APP-CON system given here overcomes the aforesaid problems by using a single microcontroller and moreover a simple program or software for bluetooth enabled cell phone and employing simple coding and decoding of remote signals. Here the mobile based remote control is used to operate a number of home appliances basically consists of Bluetooth technology. The unit consists of a transmitter and a receiver consisting of a microcontroller. The importance of bluetooth technology is that the signal to be transmitted from transmitter to the receiver is done without requiring line of sight.

  2. The energy-related services are the major sales promotion. Customized electricity and district heat supply technology and services for the newly developed residential area Boerkhauser Feld at Solingen-Aufderhoehe; Die Dienstleistung bringt den (Verkaufs-)Erfolg. Strom- und Waermeversorgung fuer Wohngebiet Boerkhauser Feld in Solingen-Aufderhoehe

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2001-06-01

    The firm COMUNA-metall, Herford, is the contractor and service provider for installation and operation of the electricity and district heat supply systems based on a modular cogeneration plant (CHP system). The residential area will eventually encompass about 450 residential units, all buildings are low-energy houses. The article explains the systems and gives an initial performance report covering 100 existing residential units. (orig./CB) [German] Die Firma COMUNA-metall, Herford, hat als Dienstleister die Erstellung und den Betrieb einer Strom- und Nahwaermeversorgung mit Kraft-Waerme-Kopplung fuer das Wohngebiet uebernommen, das nach Fertigstellung ca. 450 Wohneinheiten in Niedrigenergiebauweise umfassen wird. Der Beitrag schildert die technischen Einrichtungen und eine erste Leistungsbilanz im Bauabschnitt mit 100 Wohneinheiten. (orig./CB)

  3. Electricity savings from implementation of minimum energy efficiency standard for TVs in Malaysia

    Energy Technology Data Exchange (ETDEWEB)

    Varman, M.; Masjuki, H.H.; Mahlia, T.M.I. [University of Malaya, Kuala Lumpur (Malaysia). Department of Mechanical Engineering

    2005-06-01

    The popularization of 24 h pay-TV, interactive video games, web-TV, VCD and DVD in Malaysia are poised to have a large impact on overall TV electricity consumption in the country. With the increasing of overall TV energy consumption, energy efficiency standards are one of highly effective policies for decreasing electricity consumption in the residential sector. Energy efficiency standards are also capable of reducing consumer's electricity bill and contribute towards positive environmental impacts. This paper attempts to predict the amount of energy that can be saved in the residential sector by implementing minimum energy efficiency standard for television sets in Malaysia. Over the past 30 years, television ownership in Malaysian residents has increased from 186,036 units in 1970 to 2,741,640 units in 1991. This figure is expected to reach 6,201,316 units in the year 2010. Hence, efficiency improvement for this appliance will have a significant impact on the future of electricity consumption in this country. (author)

  4. Chapter 6: Residential Lighting Evaluation Protocol

    Energy Technology Data Exchange (ETDEWEB)

    Dimetrosky, Scott [Apex Analytics LLC, Boulder, CO (United States); Parkinson, Katie [Apex Analytics LLC, Boulder, CO (United States); Lieb, Noah [Apex Analytics LLC, Boulder, CO (United States)

    2015-02-01

    In recent years, residential lighting has represented a significant share of ratepayer-funded energy-efficiency electricity savings. Utilities have achieved the majority of these savings by promoting the purchase and installation of compact fluorescent lamps (CFLs), both standard 'twister' bulbs and specialty CFLs such as reflectors, A-Lamps, globes, and dimmable lights.

  5. Removable orthodontic appliances: new perspectives on capabilities and efficiency.

    Science.gov (United States)

    Hamid Zafarmand, A; Mahdi Zafarmand, M

    2013-06-01

    Removable appliances are a dependable choice for many patients but like all orthodontic appliances, they have some limitations in use. Patient selection and appropriate appliance design are two key factors for success. Many patients, especially adults, prefer intra-oral appliances to extra-oral devices. Sometimes a removable intra-oral appliance can solve a dental problem in a shorter period of time compared to fixed treatment, and this has also been repeatedly seen in molar distalisation. From the interceptive perspective, the appliance can prevent or alleviate an impending crowding for erupting permanent incisors. This article describes 5 patients with different orthodontic problems: impending crowding for erupting upper canine with 2 approaches, provision of space for upper cuspids, resolution of chronic attrition of anterior teeth, relief of space shortage for upper canines eruption, and reduction of excess overjet. All subjects were treated with removable appliances of various designs.

  6. One watt initiative: A global effort to reduce leaking electricity

    International Nuclear Information System (INIS)

    Meier, Alan K.; LeBot, Benoit

    1999-01-01

    Many domestic appliances and commercial equipment consume some electric power when they are switched off or not performing their primary purpose. The typical loss per appliance is low (from 1 to 25 W) but, when multiplied by the billions of appliances in houses and in commercial buildings, standby losses represent a significant fraction of total electricity use. Several initiatives to reduce standby losses have appeared in different parts of the world. One proposal, the 1-watt plan, seeks to harmonize these initiatives by establishing a single target for all appliances. This paper explains the background to the 1-watt plan, identifies some unresolved aspects, and gives some estimates of energy savings

  7. Energy saving in the household. Vol. 2. A reasoning interview investigation on the current consumption differential in the summer time in a residential block estate. Energisparing i husstellet. Vol. 2. En intervju-undersoekelse om aarsaker til forskjeller i stroemforbruket om sommeren i et blokkomraade

    Energy Technology Data Exchange (ETDEWEB)

    Ilstad, S; Lund, I

    1983-01-01

    The present study represents a behavioral approach to residential energy (electricity) conservation. It is especially concerned with socio-psychological variabales like habits, attitudes, social control and mass communication. In addition to that, the effects of family structural variables (size, age, occupation, absence from home), some physical environmental variables and household equipment and appliances are investigated. (Some data on the use of private cars are also included). The sample consists of 113 appartments of identical size (94 m/sup 2/), heated by electricity. The data collection procedure included reading the electric meters in May and September 1982 and systematic interviews with each family after the second reading. The general purpose of the data analysis was to explain the variance in electricity consumption. The most important determinants for differences between families in electricity consumption during the investigated summer period were found to be: family size, number of weeks away from home, use of heating equipment, and attitudes toward energy conservation at home. A number of other factors also contributed substantially to the differences, e.g. age, the use of hot water, size and placement of home freezer, frequency of using washing mashine and dish washer, the use of light, perceived consequences of energy conservation, family cooperation etc. Practical implications for disseminating information on energy conservation in the residential sector through mass media campaigns are discussed.

  8. GE Appliance Park Louisville, KY Plant Wide Assessment Final Report October 25th, 2007

    Energy Technology Data Exchange (ETDEWEB)

    Chandon Rao; Richard Urschel

    2007-10-25

    Used a team of experts to analyze and model major systems at a large industrial appliance manufacturer. During the data gathering stage, the team specifically looked for baselining the efficiency of the systems as well as developing short term and longer term efficiency projects. Electrical distribution, Compressed air generation and thermal heat recovery for the production facility and front office heating and cooling optimization were all baselined during the study.

  9. Optimal daily operation of a smart-household under dynamic pricing considering thermostatically and non-thermostatically controllable appliances

    NARCIS (Netherlands)

    Paterakis, N.G.; Medeiros, M.F.; Catalao, J.P.S.; Siaraka, A.; Bakirtzis, A.G.; Erdinc, O.

    2015-01-01

    In this study, a home energy management system structure is developed in order to determine the optimal commitment of a smart-household. Two types of loads are explicitly modeled: non-thermostatically controllable (electric vehicle, shiftable appliances) and thermostatically controllable loads (air

  10. Oral appliances and functional orthopaedic appliances for obstructive sleep apnoea in children.

    Science.gov (United States)

    Carvalho, F R; Lentini-Oliveira, D; Machado, M A C; Prado, G F; Prado, L B F; Saconato, H

    2007-04-18

    Apnoea is a breathing disorder marked by the absence of airflow at the nose or mouth. In children, risk factors include adenotonsillar hypertrophy, obesity, neuromuscular disorders and craniofacial anomalies. The most common treatment for obstructive sleep apnoea syndrome (OSAS) in childhood is adenotonsillectomy. This approach is limited by its surgical risks, mostly in children with comorbities and, in some patients, by recurrence that can be associated with craniofacial problems. Oral appliances and functional orthopaedic appliances have been used for patients who have OSAS and craniofacial anomalies because they change the mandible posture forwards and potentially enlarge the upper airway and increase the upper airspace, improving the respiratory function. To assess the effectiveness of oral appliances or functional orthopaedic appliances for OSAS in children. A sensitive search was developed for the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2005, Issue 3); PubMed (January 1966 to September 2005); EMBASE (1980 to September 2005); Lilacs (1982 to September 2005); BBO-Bibliografia Brasileira de Odontologia (1986 to September 2005); and SciELO (1997 to September 2005). There was no restriction of language or source of information. All randomised or quasi-randomised controlled trials comparing all types of oral and functional orthopaedic appliances with placebo or no treatment, in children 15 years old or younger. reduction of apnoea to less than one episode per hour. dental and skeletal relationship, sleep parameters improvement, cognitive and phonoaudiologic function, behavioural problems, drop outs and withdrawals, quality of life, side effects (tolerability), economic evaluation. Data were independently extracted by two review authors. Authors were contacted for additional information. Risk ratios with 95% confidence intervals were calculated for all important dichotomous outcomes. The initial search identified 384 trials

  11. 77 FR 28519 - Test Procedure Guidance for Room Air Conditioners, Residential Dishwashers, and Residential...

    Science.gov (United States)

    2012-05-15

    ... Guidance for Room Air Conditioners, Residential Dishwashers, and Residential Clothes Washers: Public... procedures for room air conditioners, residential dishwashers, and residential clothes washers. DATES: DOE...'s existing test procedures for residential room air conditioners, residential dishwashers, and...

  12. Catalytic combustion in small wood burning appliances

    Energy Technology Data Exchange (ETDEWEB)

    Oravainen, H. [VTT Energy, Jyvaeskylae (Finland)

    1996-12-31

    There is over a million hand fired small heating appliances in Finland where about 5,4 million cubic meters of wood fuel is used. Combustion in such heating appliances is a batch-type process. In early stages of combustion when volatiles are burned, the formation of carbon monoxide (CO) and other combustible gases are difficult to avoid when using fuels that have high volatile matter content. Harmful emissions are formed mostly after each fuel adding but also during char burnout period. When the CO-content in flue gases is, say over 0.5 %, also other harmful emissions will be formed. Methane (CH{sub 4}) and other hydrocarbons are released