WorldWideScience

Sample records for research nist ncnr

  1. A new polarized neutron interferometry facility at the NCNR

    Energy Technology Data Exchange (ETDEWEB)

    Shahi, C.B. [Physics and Engineering Physics Department, Tulane University, New Orleans, LA 70188 (United States); Arif, M. [National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States); Cory, D.G. [Department of Chemistry, University of Waterloo, Waterloo, ON, Canada N2L 3G1 (Canada); Perimeter Institute for Theoretical Physics, Waterloo, ON, Canada N2L 2Y5 (Canada); Institute for Quantum Computing, University of Waterloo, Waterloo, ON, Canada N2L 3G1 (Canada); Canadian Institute for Advanced Research, Toronto, ON, Canada M5G 1Z8 (Canada); Mineeva, T. [Department of Physics and Astronomy, University of Waterloo, Waterloo, ON, Canada N2L 3G1 (Canada); Canadian Institute for Advanced Research, Toronto, ON, Canada M5G 1Z8 (Canada); Nsofini, J.; Sarenac, D. [Institute for Quantum Computing, University of Waterloo, Waterloo, ON, Canada N2L 3G1 (Canada); Department of Physics and Astronomy, University of Waterloo, Waterloo, ON, Canada N2L 3G1 (Canada); Williams, C.J. [National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States); Huber, M.G., E-mail: michael.huber@nist.gov [National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States); Pushin, D.A., E-mail: dmitry.pushin@uwaterloo.ca [Institute for Quantum Computing, University of Waterloo, Waterloo, ON, Canada N2L 3G1 (Canada); Department of Physics and Astronomy, University of Waterloo, Waterloo, ON, Canada N2L 3G1 (Canada)

    2016-03-21

    A new monochromatic beamline and facility has been installed at the National Institute of Standards and Technology (NIST) Center for Neutron Research (NCNR) devoted to neutron interferometry in the research areas of spin control, spin manipulation, quantum mechanics, quantum information science, spintronics, and material science. This facility is possible in part because of advances in decoherence free subspace interferometer designs that have demonstrated consistent contrast in the presence of vibrational noise; a major environmental constraint that has prevented neutron interferometry from being applied at other neutron facilities. Neutron interferometry measures the phase difference between a neutron wave function propagating along two spatially separated paths. It is a practical example of self interference and due to its modest path separation of a few centimeters allows the insertion of samples and macroscopic neutron spin rotators. Phase shifts can be caused by gravitational, magnetic and nuclear interactions as well as purely quantum mechanical effects making interferometer a robust tool in neutron research. This new facility is located in the guide hall of the NCNR upstream of the existing Neutron Interferometry and Optics Facility (NIOF) and has several advantages over the NIOF including higher incident flux, better neutron polarization, and increased accessibility. The long term goal for the new facility is to be a user supported beamline and makes neutron interferometer more generally available to the scientific community. This paper addresses both the capabilities and characteristics of the new facility.

  2. Conversion Preliminary Safety Analysis Report for the NIST Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Diamond, D. J. [Brookhaven National Lab. (BNL), Upton, NY (United States); Baek, J. S. [Brookhaven National Lab. (BNL), Upton, NY (United States); Hanson, A. L. [Brookhaven National Lab. (BNL), Upton, NY (United States); Cheng, L-Y [Brookhaven National Lab. (BNL), Upton, NY (United States); Brown, N. [Brookhaven National Lab. (BNL), Upton, NY (United States); Cuadra, A. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2015-01-30

    The NIST Center for Neutron Research (NCNR) is a reactor-laboratory complex providing the National Institute of Standards and Technology (NIST) and the nation with a world-class facility for the performance of neutron-based research. The heart of this facility is the NIST research reactor (aka NBSR); a heavy water moderated and cooled reactor operating at 20 MW. It is fueled with high-enriched uranium (HEU) fuel elements. A Global Threat Reduction Initiative (GTRI) program is underway to convert the reactor to low-enriched uranium (LEU) fuel. This program includes the qualification of the proposed fuel, uranium and molybdenum alloy foil clad in an aluminum alloy, and the development of the fabrication techniques. This report is a preliminary version of the Safety Analysis Report (SAR) that would be submitted to the U.S. Nuclear Regulatory Commission (NRC) for approval prior to conversion. The report follows the recommended format and content from the NRC codified in NUREG-1537, “Guidelines for Preparing and Reviewing Applications for the Licensing of Non-power Reactors,” Chapter 18, “Highly Enriched to Low-Enriched Uranium Conversions.” The emphasis in any conversion SAR is to explain the differences between the LEU and HEU cores and to show the acceptability of the new design; there is no need to repeat information regarding the current reactor that will not change upon conversion. Hence, as seen in the report, the bulk of the SAR is devoted to Chapter 4, Reactor Description, and Chapter 13, Safety Analysis.

  3. A Liquid Deuterium Cold Neutron Source for the NIST Research Reactor - Conceptual Design

    International Nuclear Information System (INIS)

    Williams, R. E.; Middleton, M.; Kopetka, P.; Rowe, J. M.; Brand, P. C.

    2013-01-01

    The NBSR is a 20 MW research reactor operated by the NIST Center for Neutron Research (NCNR) as a neutron source providing beams of thermal and cold neutrons for research in materials science, fundamental physics and nuclear chemistry. A large, 550 mm diameter beam port was included in the design for the installation of a cold neutron source, and the NCNR has been steadily improving its cold neutron facilities for more than 25 years. Monte Carlo Simulations have shown that a liquid deuterium (LD 2 ) source will provide a gain of 1.5 to 2 for neutron wavelengths between 4 A and 10 A with respect to the existing liquid hydrogen cold source. The conceptual design for the LD 2 source will be presented. To achieve these gains, a large volume (35 litres) of LD 2 is required. The expected nuclear heat load in this moderator and vessel is 4000 W. A new, 7 kW helium refrigerator is being built to provide the necessary cooling capacity; it will be completely installed and tested early in 2014. The source will operate as a naturally circulating thermosiphon, very similar to the horizontal cold source in the High Flux Reactor at the Institut Laue-Langevin (ILL) in Grenoble. A condenser will be mounted on the reactor face about 2 m above the source providing the gravitational head to supply the source with LD 2 . The system will always be open to a 16 m3 ballast tank to store the deuterium at 500 kPa when the refrigerator is not operating, and providing a passively safe response to a refrigerator trip. It is expected the source will operate at 23 K, the boiling point of LD 2 at 100 kPa. All components will be surrounded by a blanket of helium to prevent the possibility of creating a flammable mixture of deuterium and air. A design for the cryostat assembly, consisting of the moderator chamber, vacuum jacket, helium containment and a heavy water cooling water jacket, has been completed and sent to procurement to solicit bids. It is expected that installation of the LD 2 cold

  4. A Liquid Deuterium Cold Neutron Source for the NIST Research Reactor - Conceptual Design

    Energy Technology Data Exchange (ETDEWEB)

    Williams, R. E.; Middleton, M.; Kopetka, P.; Rowe, J. M.; Brand, P. C. [NIST Center for Neutron Research, Gaithersburg (United States)

    2013-07-01

    The NBSR is a 20 MW research reactor operated by the NIST Center for Neutron Research (NCNR) as a neutron source providing beams of thermal and cold neutrons for research in materials science, fundamental physics and nuclear chemistry. A large, 550 mm diameter beam port was included in the design for the installation of a cold neutron source, and the NCNR has been steadily improving its cold neutron facilities for more than 25 years. Monte Carlo Simulations have shown that a liquid deuterium (LD{sub 2}) source will provide a gain of 1.5 to 2 for neutron wavelengths between 4 A and 10 A with respect to the existing liquid hydrogen cold source. The conceptual design for the LD{sub 2} source will be presented. To achieve these gains, a large volume (35 litres) of LD{sub 2} is required. The expected nuclear heat load in this moderator and vessel is 4000 W. A new, 7 kW helium refrigerator is being built to provide the necessary cooling capacity; it will be completely installed and tested early in 2014. The source will operate as a naturally circulating thermosiphon, very similar to the horizontal cold source in the High Flux Reactor at the Institut Laue-Langevin (ILL) in Grenoble. A condenser will be mounted on the reactor face about 2 m above the source providing the gravitational head to supply the source with LD{sub 2}. The system will always be open to a 16 m3 ballast tank to store the deuterium at 500 kPa when the refrigerator is not operating, and providing a passively safe response to a refrigerator trip. It is expected the source will operate at 23 K, the boiling point of LD{sub 2} at 100 kPa. All components will be surrounded by a blanket of helium to prevent the possibility of creating a flammable mixture of deuterium and air. A design for the cryostat assembly, consisting of the moderator chamber, vacuum jacket, helium containment and a heavy water cooling water jacket, has been completed and sent to procurement to solicit bids. It is expected that

  5. 75 FR 18784 - FY 2010 NIST Center for Neutron Research (NCNR) Comprehensive Grants Program

    Science.gov (United States)

    2010-04-13

    ... regarding the use of human embryonic stem cells in research. On July 30, 2009, President Obama issued a memorandum directing that agencies that support and conduct stem cell research adopt the ``National Institutes of Health Guidelines for Human Stem Cell Research'' (NIH Guidelines), which became effective on...

  6. Reference metrology in a research fab: the NIST clean calibrations thrust

    Science.gov (United States)

    Dixson, Ronald; Fu, Joe; Orji, Ndubuisi; Renegar, Thomas; Zheng, Alan; Vorburger, Theodore; Hilton, Al; Cangemi, Marc; Chen, Lei; Hernandez, Mike; Hajdaj, Russell; Bishop, Michael; Cordes, Aaron

    2009-03-01

    In 2004, the National Institute of Standards and Technology (NIST) commissioned the Advanced Measurement Laboratory (AML) - a state-of-the-art, five-wing laboratory complex for leading edge NIST research. The NIST NanoFab - a 1765 m2 (19,000 ft2) clean room with 743 m2 (8000 ft2) of class 100 space - is the anchor of this facility and an integral component of the new Center for Nanoscale Science and Technology (CNST) at NIST. Although the CNST/NanoFab is a nanotechnology research facility with a different strategic focus than a current high volume semiconductor fab, metrology tools still play an important role in the nanofabrication research conducted here. Some of the metrology tools available to users of the NanoFab include stylus profiling, scanning electron microscopy (SEM), and atomic force microscopy (AFM). Since 2001, NIST has collaborated with SEMATECH to implement a reference measurement system (RMS) using critical dimension atomic force microscopy (CD-AFM). NIST brought metrology expertise to the table and SEMATECH provided access to leading edge metrology tools in their clean room facility in Austin. Now, in the newly launched "clean calibrations" thrust at NIST, we are implementing the reference metrology paradigm on several tools in the CNST/NanoFab. Initially, we have focused on calibration, monitoring, and uncertainty analysis for a three-tool set consisting of a stylus profiler, an SEM, and an AFM. Our larger goal is the development of new and supplemental calibrations and standards that will benefit from the Class 100 environment available in the NanoFab and offering our customers calibration options that do not require exposing their samples to less clean environments. Toward this end, we have completed a preliminary evaluation of the performance of these instruments. The results of these evaluations suggest that the achievable uncertainties are generally consistent with our measurement goals.

  7. NIST Accelerator Facilities And Programs In Support Of Industrial Radiation Research

    International Nuclear Information System (INIS)

    Bateman, F.B.; Desrosiers, M.F.; Hudson, L.T.; Coursey, B.M.; Bergstrom, P.M. Jr.; Seltzer, S.M.

    2003-01-01

    NIST's Ionizing Radiation Division maintains and operates three electron accelerators used in a number of applications including waste treatment and sterilization, radiation hardness testing, detector calibrations and materials modification studies. These facilities serve a large number of governmental, academic and industrial users as well as an active intramural research program. They include a 500 kV cascaded-rectifier accelerator, a 2.5 MV electron Van de Graaff accelerator and a 7 to 32 MeV electron linac, supplying beams ranging in energy from a few keV up to 32 MeV. In response to the recent anthrax incident, NIST along with the US Postal Service and the Armed Forces Radiobiology Research Institute (AFRRI) are working to develop protocols and testing procedures for the USPS mail sanitization program. NIST facilities and personnel are being employed in a series of quality-assurance measurements for both electron- and photon-beam sanitization. These include computational modeling, dose verification and VOC (volatile organic compounds) testing using megavoltage electron and photon sources

  8. The reactor and cold neutron research facility at NIST

    Energy Technology Data Exchange (ETDEWEB)

    Prask, H J; Rowe, J M [Reactor Radiation Division, National Institute of Standards and Technology, Gaithersburg, MD (United States)

    1992-07-01

    The NIST Reactor (NBSR) is a 20 MW research reactor located at the Gaithersburg, MD site, and has been in operation since 1969. It services 26 thermal neutron facilities which are used for materials science, chemical analysis, nondestructive evaluation, neutron standards work, and irradiations. In 1987 the Department of Commerce and NIST began development of the CNRF - a $30M National Facility for cold neutron research -which will provide fifteen new experimental stations with capabilities currently unavailable in this country. As of May 1992, four of the planned seven guides and a cold port were installed, eight cold neutron experimental stations were operational, and the Call for Proposals for the second cycle of formally-reviewed guest-researcher experiments had been sent out. Some details of the performance of instrumentation are described, along with the proposed design of the new hydrogen cold source which will replace the present D{sub 2}O/H{sub 2}O ice cold source. (author)

  9. The reactor and cold neutron research facility at NIST

    International Nuclear Information System (INIS)

    Prask, H.J.; Rowe, J.M.

    1992-01-01

    The NIST Reactor (NBSR) is a 20 MW research reactor located at the Gaithersburg, MD site, and has been in operation since 1969. It services 26 thermal neutron facilities which are used for materials science, chemical analysis, nondestructive evaluation, neutron standards work, and irradiations. In 1987 the Department of Commerce and NIST began development of the CNRF - a $30M National Facility for cold neutron research -which will provide fifteen new experimental stations with capabilities currently unavailable in this country. As of May 1992, four of the planned seven guides and a cold port were installed, eight cold neutron experimental stations were operational, and the Call for Proposals for the second cycle of formally-reviewed guest-researcher experiments had been sent out. Some details of the performance of instrumentation are described, along with the proposed design of the new hydrogen cold source which will replace the present D 2 O/H 2 O ice cold source. (author)

  10. Results and Systematic Studies of the UCN Lifetime Experiment at NIST

    Science.gov (United States)

    Huffer, Craig Reeves

    The neutron beta-decay lifetime is important in understanding weak interactions in the framework of the Standard Model, and it is an input to nuclear astrophysics and Big Bang Nucleosynthesis. Current measurements of the neutron beta-decay lifetime disagree, which has motivated additional experiments that are sensitive to different sets of systematic effects. An effort continues at the NIST Center for Neutron Research (NCNR) to improve the statistical and systematic limitations of an experiment to measure the neutron beta-decay lifetime using magnetically trapped UCN. In the experiment, a monoenergetic 0:89 nm cold neutron is incident on a superfluid 4He target within the minimum field region of an Ioffe type magnetic trap. Some of the neutrons are subsequently downscattered by single phonons in the helium to low energies (≈ 200 neV), and those in the appropriate spin state become trapped. The inverse process, upscattering of UCN, is suppressed by the low phonon density in the analysis, data, and systematics will be discussed. After accounting for the systematic effects the measured lifetime disagrees with the current PDG mean neutron beta-decay lifetime by about 9 of our standard deviations, which is a strong indication of unaccounted for systematic effects. Additional 3He contamination will be shown to be the most likely candidate for the additional systematic shift, which motivated the commissioning and initial operation of a heat flush purifier for purifying additional 4He. This work ends with a description of the 4He purifier and its performance.

  11. The liquid hydrogen moderator at the NIST research reactor

    International Nuclear Information System (INIS)

    Williams, Robert E.; Rowe, J. Michael; Kopetka, Paul

    1997-09-01

    In 1995, the NIST research reactor was shut down for a number of modifications, including the replacement of the D 2 O cold neutron source with a liquid hydrogen moderator. When the liquid hydrogen source began operating, the flux of cold neutrons increased by a factor of six over the D 2 O source. The design and operation of the hydrogen source are described, and measurements of its performance are compared with the Monte Carlo simulations used in the design. (auth)

  12. NIST commitment to national MQA programs

    Energy Technology Data Exchange (ETDEWEB)

    Caswell, R.S. [National Institute of Standards and Technology, Gaithersburg, MD (United States)

    1993-12-31

    The program of the Ionizing Radiation Division, Physics Laboratory is discussed, especially relating to standards, calibrations, and measurement quality assurance (MQA). The NIST program is {open_quotes}vertically integrated,{close_quotes} meaning that activities extend from fundamental research to measurement research to supplying services and data. Typical methods NIST uses to assure the quality of the national standards are presented. Some of the programs in x-ray, gamma-ray, electron, neutron, and radioactivity research which support MQA are presented. Examples are given of MQA activities.

  13. NIST commitment to national MQA programs

    International Nuclear Information System (INIS)

    Caswell, R.S.

    1993-01-01

    The program of the Ionizing Radiation Division, Physics Laboratory is discussed, especially relating to standards, calibrations, and measurement quality assurance (MQA). The NIST program is open-quotes vertically integrated,close quotes meaning that activities extend from fundamental research to measurement research to supplying services and data. Typical methods NIST uses to assure the quality of the national standards are presented. Some of the programs in x-ray, gamma-ray, electron, neutron, and radioactivity research which support MQA are presented. Examples are given of MQA activities

  14. CPTC and NIST-sponsored Yeast Reference Material Now Publicly Available | Office of Cancer Clinical Proteomics Research

    Science.gov (United States)

    The yeast protein extract (RM8323) developed by National Institute of Standards and Technology (NIST) under the auspices of NCI's CPTC initiative is currently available to the public at https://www-s.nist.gov/srmors/view_detail.cfm?srm=8323. The yeast proteome offers researchers a unique biological reference material. RM8323 is the most extensively characterized complex biological proteome and the only one associated with several large-scale studies to estimate protein abundance across a wide concentration range.

  15. Assessing Customer Satisfaction at the NIST Research Library: Essential Tool for Future Planning

    Science.gov (United States)

    Liu, Rosa; Allmang, Nancy

    2008-01-01

    This article describes a campus-wide customer satisfaction survey undertaken by the National Institute of Standards and Technology (NIST) Research Library in 2007. The methodology, survey instrument, data analysis, results, and actions taken in response to the survey are described. The outcome and recommendations will guide the library both…

  16. The 2016 NIST Speaker Recognition Evaluation

    Science.gov (United States)

    2017-08-20

    impact on system performance. Index Terms: NIST evaluation, NIST SRE, speaker detection, speaker recognition, speaker verification 1. Introduction NIST... self -reported. Second, there were two training conditions in SRE16, namely fixed and open. In the fixed training condition, par- ticipants were only

  17. NIST: Information Management in the AMRF

    Science.gov (United States)

    Callaghan, George (Editor)

    1991-01-01

    The information management strategies developed for the NIST Automated Manufacturing Research Facility (AMRF) - a prototype small batch manufacturing facility used for integration and measurement related standards research are outlined in this video. The five major manufacturing functions - design, process planning, off-line programming, shop floor control, and materials processing are explained and their applications demonstrated.

  18. NIST display colorimeter calibration facility

    Science.gov (United States)

    Brown, Steven W.; Ohno, Yoshihiro

    2003-07-01

    A facility has been developed at the National Institute of Standards and Technology (NIST) to provide calibration services for color-measuring instruments to address the need for improving and certifying the measurement uncertainties of this type of instrument. While NIST has active programs in photometry, flat panel display metrology, and color and appearance measurements, these are the first services offered by NIST tailored to color-measuring instruments for displays. An overview of the facility, the calibration approach, and associated uncertainties are presented. Details of a new tunable colorimetric source and the development of new transfer standard instruments are discussed.

  19. Performance of the advanced cold neutron source and optics upgrades at the NIST Research Reactor

    International Nuclear Information System (INIS)

    Williams, R.E.; Kopetka, P.; Cook, J.C.; Rowe, J.M.

    2003-01-01

    On March 6, 2002, the NIST Research Reactor resumed routine operation following a six-month shutdown for facility upgrades and maintenance. During the shutdown, the original liquid hydrogen cold neutron source was removed, and the advanced cold source was installed. An optical filter was installed on one of the neutron guides, NG-3, replacing a crystal filter for the 30-m SANS instrument and the guide used between the chopper disks of the Disk Chopper time-of-flight Spectrometer (DCS) installed on NG-4 has been recently reconfigured. Additional improvements in the neutron optics of various instruments are being made. The advanced liquid hydrogen cold neutron source performs as expected, nearly doubling the flux available to most instruments. The measured gains range from about 1.4 at 2 A, to over a factor of two at 15 A. Also as expected, the heat load in the new source increased to 1200 watts, but the previously existing refrigerator has easily accommodated the increase. With intensity gains of a factor of two in the important long wavelength region of the spectrum, the advanced cold source significantly enhances the measurement capability of the cold neutron scattering instrumentation at NIST. The optical filter on NG-3 is also very successful; the 30-m SANS has an additional gain of two at 17 A. A system of refracting lenses and prisms near the SANS sample position has made possible measurements at low Q (0.0005 A -1 ) that were previously not feasible. The DCS has also seen additional intensity gain factors in excess of two for the majority of experiments and at short neutron wavelengths the gains exceed three. In addition, two new triple axis spectrometers will feature double-focusing monochromators in order to exploit the full size of the available thermal and cold neutron beam tubes. The success of the advanced cold source and enhanced neutron optics contributed to the recognition of the NIST Center for Neutron Research as 'the premiere neutron scattering

  20. NIST Gonio-spectroradiometer

    Data.gov (United States)

    Federal Laboratory Consortium — The NIST gonio-spectroradiometer is used to measure total spectral radiant flux (TSRF) of incandescent lamps. The instrument consists of a 3-axis scanning mechanism;...

  1. The new NIST atomic spectra database

    International Nuclear Information System (INIS)

    Kelleher, D.E.; Martin, W.C.; Wiese, W.L.; Sugar, J.; Fuhr, J.R.; Olsen, K.; Musgrove, A.; Mohr, P.J.; Reader, J.; Dalton, G.R.

    1999-01-01

    The new atomic spectra database (ASD), Version 2.0, of the National Institute of Standards and Technology (NIST) contains significantly more data and covers a wider range of atomic and ionic transitions and energy levels than earlier versions. All data are integrated. It also has a new user interface and search engine. ASD contains spectral reference data which have been critically evaluated and compiled by NIST. Version 2.0 contains data on 900 spectra, with about 70000 energy levels and 91000 lines ranging from about 1 Aangstroem to 200 micrometers, roughly half of which have transition probabilities with estimated uncertainties. References to the NIST compilations and original data sources are listed in the ASD bibliography. A detailed ''Help'' file serves as a user's manual, and full search and filter capabilities are provided. (orig.)

  2. In-situ burning: NIST studies

    International Nuclear Information System (INIS)

    Evans, D.D.

    1992-01-01

    In-situ burning of spilled oil has distinct advantages over other countermeasures. It offers the potential to convert rapidly large quantities of oil into its primary combustion products, carbon dioxide and water, with a small percentage of other unburned and residue byproducts. Because the oil is converted to gaseous products of combustion by burning, the need for physical collection, storage, and transport of recovered fluids is reduced to the few percent of the original spill volume that remains as residue after burning. Burning oil spills produces a visible smoke plume containing smoke particulate and other products of combustion which may persist for many kilometers from the burn. This fact gives rise to public health concerns, related to the chemical content of the smoke plume and the downwind deposition of particulate, which need to be answered. In 1985, a joint Minerals Management Service (MMS) and Environment Canada (EC) in-situ burning research program was begun at the National Institute of Standards and Technology (NIST). This research program was designed to study the burning of large crude oil spills on water and how this burning would affect air quality by quantifying the products of combustion and developing methods to predict the downwind smoke particulate deposition. To understand the important features of in-situ burning, it is necessary to perform both laboratory and mesoscale experiments. Finally, actual burns of spilled oil at sea will be necessary to evaluate the method at the anticipated scale of actual response operations. In this research program there is a continuing interaction between findings from measurements on small fire experiments performed in the controlled laboratory environments of NIST and the Fire Research Institute (FRI) in Japan, and large fire experiments at facilities like the USCG Fire Safety and Test Detachment in Mobile, Alabama where outdoor liquid fuel burns in large pans are possible

  3. 77 FR 18791 - Proposed Information Collection; Comment Request; NIST Associates Information System

    Science.gov (United States)

    2012-03-28

    ... DEPARTMENT OF COMMERCE National Institute of Standards and Technology Proposed Information Collection; Comment Request; NIST Associates Information System AGENCY: National Institute of Standards and... access to the NIST campuses or NIST resources. The NIST Associates Information System (NAIS) information...

  4. Analysis of Bone Meal (NIST 1486) and Bone Ash (NIST 1400) reference materials by neutron activation method; Analise de materiais de referencia Bone Meal (NIST 1486) e Bone Ash (NIST 1400) pelo metodo de ativacao com neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Takata, Marcelo K.; Saiki, Mitiko [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil); Borelli, Aurelio [Sao Paulo Univ., SP (Brazil). Faculdade de Medicina

    1999-11-01

    In this work instrumental neutron activation analysis has been applied to determine Ba, ca, Cl, Cr, fe, Mg, Mn, Na, P, Sb, Sc, Sr and Zn in two biological reference materials NIST 1486 Bone Meal and NIST 1400 Bone Ash. The purpose of this work was to evaluate the precision and the accuracy of the results as well as to give a contribution to certificate these materials. Interferences found in the determination of some elements were also discussed. (author) 8 refs., 4 tabs.

  5. Measurement quality assurance for beta particle calibrations at NIST

    Energy Technology Data Exchange (ETDEWEB)

    Soares, C.G.; Pruitt, J.S. [National Institute of Standards and Technology, Gaithersburg, MD (United States)

    1993-12-31

    Standardized beta-particle fields have been established in an international standard and have been adopted for use in several U.S. dosimeter and instrument testing standards. Calibration methods and measurement quality assurance procedures employed at the National Institute of Standards and Technology (NIST) for beta-particle calibrations in these reference fields are discussed. The calibration facility including the NIST-automated extrapolation ionization chamber is described, and some sample results of calibrations are shown. Methods for establishing and maintaining traceability to NIST of secondary laboratories are discussed. Currently, there are problems in finding a good method for routine testing of traceability to NIST. Some examples of past testing methods are given and solutions to this problem are proposed.

  6. Measurement quality assurance for beta particle calibrations at NIST

    International Nuclear Information System (INIS)

    Soares, C.G.; Pruitt, J.S.

    1993-01-01

    Standardized beta-particle fields have been established in an international standard and have been adopted for use in several U.S. dosimeter and instrument testing standards. Calibration methods and measurement quality assurance procedures employed at the National Institute of Standards and Technology (NIST) for beta-particle calibrations in these reference fields are discussed. The calibration facility including the NIST-automated extrapolation ionization chamber is described, and some sample results of calibrations are shown. Methods for establishing and maintaining traceability to NIST of secondary laboratories are discussed. Currently, there are problems in finding a good method for routine testing of traceability to NIST. Some examples of past testing methods are given and solutions to this problem are proposed

  7. NIST biometric evaluations and developments

    Science.gov (United States)

    Garris, Michael D.; Wilson, Charles L.

    2005-05-01

    This paper presents an R&D framework used by the National Institute of Standards and Technology (NIST) for biometric technology testing and evaluation. The focus of this paper is on fingerprint-based verification and identification. Since 9-11 the NIST Image Group has been mandated by Congress to run a program for biometric technology assessment and biometric systems certification. Four essential areas of activity are discussed: 1) developing test datasets, 2) conducting performance assessment; 3) technology development; and 4) standards participation. A description of activities and accomplishments are provided for each of these areas. In the process, methods of performance testing are described and results from specific biometric technology evaluations are presented. This framework is anticipated to have broad applicability to other technology and application domains.

  8. NIST high-dose calibration services

    International Nuclear Information System (INIS)

    Humphreys, J.C.

    1989-01-01

    There is a need for the standardization of high-dose measurements used in the radiation-processing industry in order to provide assured traceability to national standards. NIST provides dosimetry calibration services to this industry. One of these services involves administration of known absorbed doses of gamma rays to customer-supplied dosimeters. The dosimeters are packaged to provide electron equilibrium conditions and are irradiated in a standard 60 Co calibration facility; this provides a calibration of that batch of dosimeters. Another service consists of supplying to a customer calibrated transfer dosimeters for irradiation with the customer's radiation source. The irradiated transfer dosimeters are then returned to NIST for analysis; the results are reported to the customer, providing a calibration of the dose rate of the customer's source. (orig.)

  9. Recent Developments in the NIST Atomic Databases

    Science.gov (United States)

    Kramida, Alexander

    2011-05-01

    New versions of the NIST Atomic Spectra Database (ASD, v. 4.0) and three bibliographic databases (Atomic Energy Levels and Spectra, v. 2.0, Atomic Transition Probabilities, v. 9.0, and Atomic Line Broadening and Shapes, v. 3.0) have recently been released. In this contribution I will describe the main changes in the way users get the data through the Web. The contents of ASD have been significantly extended. In particular, the data on highly ionized tungsten (W III-LXXIV) have been added from a recently published NIST compilation. The tables for Fe I and Fe II have been replaced with newer, much more extensive lists (10000 lines for Fe I). The other updated or new spectra include H, D, T, He I-II, Li I-III, Be I-IV, B I-V, C I-II, N I-II, O I-II, Na I-X, K I-XIX, and Hg I. The new version of ASD now incorporates data on isotopes of several elements. I will describe some of the issues the NIST ASD Team faces when updating the data.

  10. Recent Developments in the NIST Atomic Databases

    International Nuclear Information System (INIS)

    Kramida, Alexander

    2011-01-01

    New versions of the NIST Atomic Spectra Database (ASD, v. 4.0) and three bibliographic databases (Atomic Energy Levels and Spectra, v. 2.0, Atomic Transition Probabilities, v. 9.0, and Atomic Line Broadening and Shapes, v. 3.0) have recently been released. In this contribution I will describe the main changes in the way users get the data through the Web. The contents of ASD have been significantly extended. In particular, the data on highly ionized tungsten (W III-LXXIV) have been added from a recently published NIST compilation. The tables for Fe I and Fe II have been replaced with newer, much more extensive lists (10000 lines for Fe I). The other updated or new spectra include H, D, T, He I-II, Li I-III, Be I-IV, B I-V, C I-II, N I-II, O I-II, Na I-X, K I-XIX, and Hg I. The new version of ASD now incorporates data on isotopes of several elements. I will describe some of the issues the NIST ASD Team faces when updating the data.

  11. Eulerian–Lagrangian RANS Model Simulations of the NIST Turbulent Methanol Spray Flame

    NARCIS (Netherlands)

    Zhu, Shanglong; Roekaerts, Dirk; Pozarlik, Artur Krzysztof; van der Meer, Theodorus H.

    2015-01-01

    A methanol spray flame in a combustion chamber of the NIST was simulated using an Eulerian–Lagrangian RANS model. Experimental data and previous numerical investigations by other researchers on this flame were analyzed to develop methods for more comprehensive model validation. The inlet boundary

  12. The NIST natural-matrix radionuclide standard reference material program for ocean studies

    International Nuclear Information System (INIS)

    Inn, K.G.W.; Zhichao Lin; Zhongyu Wu; MacMahon, C.; Filliben, J.J.; Krey, P.; Feiner, M.; Harvey, J.

    2001-01-01

    -dried shellfish flesh matrix has been prepared and recently sent to participating laboratories for analysis and we anticipate receiving radioanalytical results in 2000. The research and development work at NIST produce well characterized SRMs that provide the world's environment-studies community with an important foundation component for radionuclide metrology. (author)

  13. An advanced liquid hydrogen cold source for the NIST research reactor

    International Nuclear Information System (INIS)

    Williams, R.E.; Kopetka, P.; Rowe, J.M.

    1999-01-01

    A second-generation liquid hydrogen cold neutron source is currently being fabricated and will be installed in the NIST reactor early next year. The existing source has operated very successfully over the last four years, providing a six-fold increase in the cold neutron yield compared to the previous heavy ice source. The design of the new source is based on our operating experience with the existing LH 2 source and extensive neutron transport calculations using improved MCNP modeling and computational capabilities. Enhanced mechanical design and manufacturing tools are exploited in the fabrication of the advanced source, which is expected to nearly double the yield of the existing LH 2 source. (author)

  14. Calculation of radioactivity of β-nuclides by CIEMAT/NIST method

    International Nuclear Information System (INIS)

    Shu Fujun; Zhang Shengdong; Ding Youqian; Sun Hongqing; Tang Peijia

    2010-01-01

    CIEMAT/NIST method for calculating radioactivity of β-nuclides was introduced in this paper. The influences of KB value and quenching parameter on the radioactivity computation of 241 Pu, 106 Ru/ 106 Rh, 63 Ni, 151 Sm and 14 C were studied by CIEMAT/NIST method with 3 H tracing. It is shown that the effect of KB value can be ignored if it varies in a proper range; Except for 106 Ru/ 106 Rh, the discrepancy between prediction and actual activity is lower than 2% in low quenching extent. However, it increases with quenching extent, and the largest discrepancy soars to nearly 13%. In addition, the reason for bad agreement of 106 Ru/ 106 Rh between prediction and actual activity was discussed. Efficiency calibration curves of 79 Se, 93 Zr and 107 Pd were also computed by CIEMAT/NIST method, compared with approximate replacement method or fitting and interpolation method. It is shown that CIEMAT/NIST method is no more accurate and suitable than the other two techniques. (authors)

  15. Calibrating NIST SRM 683 as A New International Reference Standard for Zn Isotopes

    Science.gov (United States)

    Yang, Y.; Zhang, X.; Yu, H.; Huang, F.

    2017-12-01

    Zinc isotopes have been widely applied in the cosmochemical, geochemical, and environmental studies (Moynier et al. 2017). Obtaining precise Zn isotopic data for inter-laboratory comparison is a prerequisite to these applications. Currently, the JMC3-0749L is the primary reference standard for Zn isotopes (Albarède 2004), but it is not commercially available now. Thus, it is necessary to calibrate a new international primary reference standard for Zn isotopic analysis. Chen et al. (2016) showed that NIST SRM 683 (a pure Zn metal nugget of 140 grams) has a δ66ZnJMC of 0.12‰, which is falling within the range of natural Zn isotopic compositions, and it may a good candidate for the next generation of international reference standard (Chen et al. 2016). In order to further examine whether NIST SRM 683 has a homogeneous Zn isotopic composition, we measured more NIST SRM 683 by double-spike methods using MC-ICPMS (Conway et al. 2013). The metal nuggets of NIST SRM 683 were intensively sampled by micro-drilling. Zinc isotope analyses for two nuggets show that they have δ66Zn of 0.14 ± 0.02‰ (2SD, N = 32) and 0.13 ± 0.02‰ (2SD, N = 33), respectively. These values are similar to those of two Zn metal nuggets (0.11 ± 0.02‰ vs. 0.12 ± 0.02‰) reported previously by Chen et al. (2016). We fully dissolved one nugget, producing pure Zn solution with identical Zn isotopic composition with the drilling samples. All results strongly support that NIST SRM 683 is homogeneous in Zn isotopic compositions which could be an ideal candidate for the next reference for Zn isotopes. Tests on more metal nuggets will be performed in a few months for further confirming the Zn isotope compositions and homogeneity. Reference: Albarède et al., 2004. 'The stable isotope geochemistry of copper and zinc', Reviews in Mineralogy and Geochemistry, 55: 409-27. Chen et al., 2016. 'Zinc Isotopic Compositions of NIST SRM 683 and Whole-Rock Reference Materials', Geostandards and

  16. Hg0 and HgCl2 Reference Gas Standards: ?NIST Traceability ...

    Science.gov (United States)

    EPA and NIST have collaborated to establish the necessary procedures for establishing the required NIST traceability of commercially-provided Hg0 and HgCl2 reference generators. This presentation will discuss the approach of a joint EPA/NIST study to accurately quantify the true concentrations of Hg0 and HgCl2 reference gases produced from high quality, NIST-traceable, commercial Hg0 and HgCl2 generators. This presentation will also discuss the availability of HCl and Hg0 compressed reference gas standards as a result of EPA's recently approved Alternative Methods 114 and 118. Gaseous elemental mercury (Hg0) and oxidized mercury (HgCl2) reference standards are integral to the use of mercury continuous emissions monitoring systems (Hg CEMS) for regulatory compliance emissions monitoring. However, a quantitative disparity of approximately 7-10% has been observed between commercial Hg0 and HgCl2 reference gases which currently limits the use of (HgCl2) reference gas standards. Resolving this disparity would enable the expanded use of (HgCl2) reference gas standards for regulatory compliance purposes.

  17. NIST/ASME Steam Properties Database

    Science.gov (United States)

    SRD 10 NIST/ASME Steam Properties Database (PC database for purchase)   Based upon the International Association for the Properties of Water and Steam (IAPWS) 1995 formulation for the thermodynamic properties of water and the most recent IAPWS formulations for transport and other properties, this updated version provides water properties over a wide range of conditions according to the accepted international standards.

  18. Consensus values for NIST biological and environmental Standard Reference Materials

    International Nuclear Information System (INIS)

    Roelandts, I.; Gladney, E.S.

    1998-01-01

    The National Institute of Standards and Technology (NIST, formerly the National Bureau of Standards or NBS) has produced numerous Standard Reference Materials (SRM) for use in biological and environmental analytical chemistry. The value listed on the ''NIST Certificate of Analysis'' is the present best estimate of the ''true'' concentration of that element and is not expected to deviate from that concentration by more than the stated uncertainty. However, NIST does not certify the elemental concentration of every constituent and the number of elements reported in the NIST programs tends to be limited.Numerous analysts have published concentration data on these reference materials. Major journals in analytical chemistry, books, proceedings and ''technical reports'' have been surveyed to collect these available literature values. A standard statistical approach has been employed to evaluate the compiled data. Our methodology has been developed in a series of previous papers. Some subjective criteria are first used to reject aberrant data. Following these eliminations, an initial arithmetic mean and standard deviation (S.D.) are computed from remaining data for each element. All data now outside two S.D. from the initial mean are dropped and a second mean and S.D. recalculated. These final means and associated S.D. are reported as ''consensus values'' in our tables. (orig.)

  19. Test of sup 3 He-based neutron polarizers at NIST

    CERN Document Server

    Jones, G L; Thompson, A K; Chowdhuri, Z; Dewey, M S; Snow, W M; Wietfeldt, F E

    2000-01-01

    Neutron spin filters based on polarized sup 3 He are useful over a wide neutron energy range and have a large angular acceptance among other advantages. Two optical pumping methods, spin-exchange and metastability-exchange, can produce the volume of highly polarized sup 3 He gas required for such neutron spin filters. We report a test of polarizers based on each of these two methods on a new cold, monochromatic neutron beam line at the NIST Center for Neutron Research.

  20. Analysis of Loss-of-Coolant Accidents in the NIST Research Reactor - Early Phase

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Joo S.; Diamond, David

    2016-12-06

    A study of the fuel temperature during the early phase of a loss-of-coolant accident (LOCA) in the NIST research reactor (NBSR) was completed. Previous studies had been reported in the preliminary safety analysis report for the conversion of the NBSR from high-enriched uranium (HEU) fuel to low-enriched (LEU) fuel. Those studies had focused on the most vulnerable LOCA situation, namely, a double-ended guillotine break in the time period after reactor trip when water is drained from either the coolant channels inside the fuel elements or the region outside the fuel elements. The current study fills in a gap in the analysis which is the early phase of the event when there may still be water present but the reactor is at power or immediately after reactor trip and pumps have tripped. The calculations were done, for both the current HEU-fueled core and the proposed LEU core, with the TRACE thermal-hydraulic systems code. Several break locations and different break sizes were considered. In all cases the increase in the clad (or fuel meat) temperature was relatively small so that a large margin to the temperature threshold for blistering (the Safety Limit for the NBSR) remained.

  1. Resorting the NIST undulator using simulated annealing for field error reduction

    International Nuclear Information System (INIS)

    Denbeaux, Greg; Johnson, Lewis E.; Madey, John M.J.

    2000-01-01

    We have used a simulated annealing algorithm to sort the samarium cobalt blocks and vanadium permendur poles in the hybrid NIST undulator to optimize the spectrum of the emitted light. While simulated annealing has proven highly effective in sorting of the SmCo blocks in pure REC undulators, the reliance on magnetically 'soft' poles operating near saturation to concentrate the flux in hybrid undulators introduces a pair of additional variables - the permeability and saturation induction of the poles - which limit the utility of the assumption of superposition on which most simulated annealing codes rely. Detailed magnetic measurements clearly demonstrated the failure of the superposition principle due to random variations in the permeability in the 'unsorted' NIST undulator. To deal with the issue, we measured both the magnetization of the REC blocks and the permeability of the NIST's integrated vanadium permendur poles, and implemented a sorting criteria which minimized the pole-to-pole variations in permeability to satisfy the criteria for realization of superposition on a nearest-neighbor basis. Though still imperfect, the computed spectrum of the radiation from the re-sorted and annealed NIST undulator is significantly superior to that of the original, unsorted device

  2. 76 FR 43264 - Proposed Information Collection; Comment Request; NIST MEP Client Impact Survey

    Science.gov (United States)

    2011-07-20

    ... DEPARTMENT OF COMMERCE National Institute of Standards and Technology Proposed Information Collection; Comment Request; NIST MEP Client Impact Survey AGENCY: National Institute of Standards and Technology (NIST), Commerce. ACTION: Notice. SUMMARY: The Department of Commerce, as part of its continuing...

  3. 77 FR 40586 - Draft NIST Interagency Report (NISTIR) 7823, Advanced Metering Infrastructure Smart Meter...

    Science.gov (United States)

    2012-07-10

    ...-01] Draft NIST Interagency Report (NISTIR) 7823, Advanced Metering Infrastructure Smart Meter... Technology (NIST) seeks comments on Draft NISTIR 7823, Advanced Metering Infrastructure Smart Meter... conformance test requirements for the firmware upgradeability process for the Advanced Metering Infrastructure...

  4. The use of high accuracy NAA for the certification of NIST Standard Reference Materials

    International Nuclear Information System (INIS)

    Becker, D.A.; Greenberg, R.R.; Stone, S.

    1991-01-01

    Neutron activation analysis (NAA) is only one of many analytical techniques used at the National Institute of Standards and Technology (NIST) for the certification of NIST Standard Reference Materials (SRMs). We compete daily against all of the other available analytical techniques in terms of accuracy, precision, and the cost required to obtain that requisite accuracy and precision. Over the years, the authors have found that NAA can and does compete favorably with these other techniques because of its' unique capabilities for redundancy and quality assurance. Good examples are the two new NIST leaf SRMs, Apple Leaves (SRM 1515) and Peach Leaves (SRM 1547). INAA was used to measure the homogeneity of 12 elements in 15 samples of each material at the 100 mg sample size. In addition, instrumental and radiochemical NAA combined for 27 elemental determinations, out of a total of 54 elemental determinations made on each material with all NIST techniques combined. This paper describes the NIST NAA procedures used in these analyses, the quality assurance techniques employed, and the analytical results for the 24 elements determined by NAA in these new botanical SRMs. The NAA results are also compared to the final certified values for these SRMs

  5. Speaker diarization system on the 2007 NIST rich transcription meeting recognition evaluation

    Science.gov (United States)

    Sun, Hanwu; Nwe, Tin Lay; Koh, Eugene Chin Wei; Bin, Ma; Li, Haizhou

    2007-09-01

    This paper presents a speaker diarization system developed at the Institute for Infocomm Research (I2R) for NIST Rich Transcription 2007 (RT-07) evaluation task. We describe in details our primary approaches for the speaker diarization on the Multiple Distant Microphones (MDM) conditions in conference room scenario. Our proposed system consists of six modules: 1). Least-mean squared (NLMS) adaptive filter for the speaker direction estimate via Time Difference of Arrival (TDOA), 2). An initial speaker clustering via two-stage TDOA histogram distribution quantization approach, 3). Multiple microphone speaker data alignment via GCC-PHAT Time Delay Estimate (TDE) among all the distant microphone channel signals, 4). A speaker clustering algorithm based on GMM modeling approach, 5). Non-speech removal via speech/non-speech verification mechanism and, 6). Silence removal via "Double-Layer Windowing"(DLW) method. We achieves error rate of 31.02% on the 2006 Spring (RT-06s) MDM evaluation task and a competitive overall error rate of 15.32% for the NIST Rich Transcription 2007 (RT-07) MDM evaluation task.

  6. Accident Analysis for the NIST Research Reactor Before and After Fuel Conversion

    Energy Technology Data Exchange (ETDEWEB)

    Baek J.; Diamond D.; Cuadra, A.; Hanson, A.L.; Cheng, L-Y.; Brown, N.R.

    2012-09-30

    Postulated accidents have been analyzed for the 20 MW D2O-moderated research reactor (NBSR) at the National Institute of Standards and Technology (NIST). The analysis has been carried out for the present core, which contains high enriched uranium (HEU) fuel and for a proposed equilibrium core with low enriched uranium (LEU) fuel. The analyses employ state-of-the-art calculational methods. Three-dimensional Monte Carlo neutron transport calculations were performed with the MCNPX code to determine homogenized fuel compositions in the lower and upper halves of each fuel element and to determine the resulting neutronic properties of the core. The accident analysis employed a model of the primary loop with the RELAP5 code. The model includes the primary pumps, shutdown pumps outlet valves, heat exchanger, fuel elements, and flow channels for both the six inner and twenty-four outer fuel elements. Evaluations were performed for the following accidents: (1) control rod withdrawal startup accident, (2) maximum reactivity insertion accident, (3) loss-of-flow accident resulting from loss of electrical power with an assumption of failure of shutdown cooling pumps, (4) loss-of-flow accident resulting from a primary pump seizure, and (5) loss-of-flow accident resulting from inadvertent throttling of a flow control valve. In addition, natural circulation cooling at low power operation was analyzed. The analysis shows that the conversion will not lead to significant changes in the safety analysis and the calculated minimum critical heat flux ratio and maximum clad temperature assure that there is adequate margin to fuel failure.

  7. National Institute of Standards and Technology (NIST) cybersecurity risk management framework applied to modern vehicles

    Science.gov (United States)

    2014-10-01

    The primary objective of the work described in this report is to review the National Institute of Science and Technology (NIST) guidelines and foundational publications from an automotive : cybersecurity risk management stand-point. The NIST approach...

  8. NIST Photoionization of CO2 (ARPES) Database

    Science.gov (United States)

    SRD 119 NIST Photoionization of CO2 (ARPES) Database (Web, free access)   CO2 is studied using dispersed synchrotron radiation in the 650 Å to 850 Å spectral region. The vibrationally resolved photoelectron spectra are analyzed to generate relative vibrational transition amplitudes and the angular asymmetry parameters describing the various transitions observed.

  9. HAPPY Team Entry to NIST OpenSAD Challenge

    DEFF Research Database (Denmark)

    Kinnunen, Tomi; Sholokhov, Alexey; Khoury, Elie

    2016-01-01

    Speech activity detection (SAD), the task of locating speech segments from a given recording, remains challenging under acoustically degraded conditions. In 2015, National Institute of Standards and Technology (NIST) coordinated OpenSAD bench-mark. We summarize “HAPPY” team effort to Open- SAD...

  10. One cubic metre NIST traceable radon test chamber

    International Nuclear Information System (INIS)

    Kotrappa, P.; Stieff, F.

    2008-01-01

    With the availability of the National Inst. of Standards and Technology (NIST) Radon Emanation Standard with a content of ∼5000 Bq of 226 Ra, it is possible to build a flow through a practical radon test chamber. A standard glove box with four gloves and a transfer port is used. Air is pumped through a flow integrator, water jar for humidification and NIST source holder, and into the glove box through a manifold. A derived theoretical expression provides the calculated radon concentration inside the chamber. The calculation includes a derived decay correction due to the large volume and low flow rate of the system. Several calibrated continuous radon monitors and passive integrating electret ion chambers tested in the chamber agreed fairly well with the calculated radon concentrations. The chamber is suitable for handling the calibration of several detectors at the same time. (authors)

  11. 77 FR 52692 - NIST Federal Information Processing Standard (FIPS) 140-3 (Second Draft), Security Requirements...

    Science.gov (United States)

    2012-08-30

    ...-03] NIST Federal Information Processing Standard (FIPS) 140-3 (Second Draft), Security Requirements....'' Authority: Federal Information Processing Standards (FIPS) are issued by the National Institute of Standards... Standards and Technology (NIST) seeks additional comments on specific sections of Federal Information...

  12. 76 FR 58248 - Proposed Information Collection; Comment Request; NIST Three-Year Generic Request for Customer...

    Science.gov (United States)

    2011-09-20

    ... Collection; Comment Request; NIST Three-Year Generic Request for Customer Service-Related Data Collections... customers want and expect, as well as their satisfaction with and awareness of existing products, services, and information. In addition, NIST proposes other customer service satisfaction data collections that...

  13. The use of high accuracy NAA for the certification of NIST botanical standard reference materials

    International Nuclear Information System (INIS)

    Becker, D.A.; Greenberg, R.R.; Stone, S.F.

    1992-01-01

    Neutron activation analysis is one of many analytical techniques used at the National Institute of Standards and Technology (NIST) for the certification of NIST Standard Reference Materials (SRMs). NAA competes favorably with all other techniques because of it's unique capabilities for high accuracy even at very low concentrations for many elements. In this paper, instrumental and radiochemical NAA results are described for 25 elements in two new NIST SRMs, SRM 1515 (Apple Leaves) and SRM 1547 (Peach Leaves), and are compared to the certified values for 19 elements in these two new botanical reference materials. (author) 7 refs.; 4 tabs

  14. 76 FR 66040 - NIST Framework and Roadmap for Smart Grid Interoperability Standards, Release 2.0 (Draft...

    Science.gov (United States)

    2011-10-25

    ...-01] NIST Framework and Roadmap for Smart Grid Interoperability Standards, Release 2.0 (Draft... draft version of the NIST Framework and Roadmap for Smart Grid Interoperability Standards, Release 2.0... Roadmap for Smart Grid Interoperability Standards, Release 2.0 (Release 2.0) (Draft) for public review and...

  15. A comparative study of 129I content in environmental standard materials IAEA-375, NIST SRM 4354 and NIST SRM 4357 by Thermal Ionization Mass Spectrometry and Accelerator Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Olson, John; Adamic, Mary; Snyder, Darin; Brookhart, Jacob; Hahn, Paula; Watrous, Matthew

    2016-11-01

    Iodine environmental measurements have consistently been backed up in the literature by standard materials like IAEA-375, Chernobyl Soil. There are not many other sources of a certified reference material for 129I content for mass spectrometry measurements. Some that have been found in the literature include NIST-4354 and NIST-4357. They are still available at the time of this writing. They don’t have certified content or isotopic values. There has been some work in the literature to show that iodine is present, but there hasn’t been enough to establish a consensus value. These materials have been analyzed at INL through two separate mass spectrometry techniques. They involve a combustion method of the starting material in oxygen, followed by TIMS analysis and a leaching preparation analyzed by accelerator mass spectrometry. Combustion/TIMS preparation of NIST SRM-4354 resulted in a 129I/127I ratio of 1.92 x 10-6 which agrees with AMS measurements which measured the 129I/127I ratio to be 1.93 x 10-6.

  16. USCEA/NIST measurement assurance programs for the radiopharmaceutical and nuclear power industries

    International Nuclear Information System (INIS)

    Golas, D.B.

    1993-01-01

    In cooperation with the U.S. Council for Energy Awareness (USCEA), the National Institute of Standards and Technology (NIST) supervises and administers two measurement assurance programs for radioactivity measurement traceability. One, in existence since the mid 1970s, provides traceability to suppliers of radiochemicals and radiopharmaceuticals, dose calibrators, and nuclear pharmacy services. The second program, begun in 1987, provides traceability to the nuclear power industry for utilities, source suppliers, and service laboratories. Each program is described, and the results of measurements of samples of known, but undisclosed activity, prepared at NIST and measured by the participants are presented

  17. USCEA/NIST measurement assurance programs for the radiopharmaceutical and nuclear power industries

    Energy Technology Data Exchange (ETDEWEB)

    Golas, D.B. [Council for Energy Awareness, Washington, DC (United States)

    1993-12-31

    In cooperation with the U.S. Council for Energy Awareness (USCEA), the National Institute of Standards and Technology (NIST) supervises and administers two measurement assurance programs for radioactivity measurement traceability. One, in existence since the mid 1970s, provides traceability to suppliers of radiochemicals and radiopharmaceuticals, dose calibrators, and nuclear pharmacy services. The second program, begun in 1987, provides traceability to the nuclear power industry for utilities, source suppliers, and service laboratories. Each program is described, and the results of measurements of samples of known, but undisclosed activity, prepared at NIST and measured by the participants are presented.

  18. Hg0 and HgCl2 Reference Gas Standards: NIST Traceability and Comparability (And EPA ALT Methods for Hg and HCl )

    Science.gov (United States)

    EPA and NIST have collaborated to establish the necessary procedures for establishing the required NIST traceability of commercially-provided Hg0 and HgCl2 reference generators. This presentation will discuss the approach of a joint EPA/NIST study to accurately quantify the tru...

  19. 75 FR 18819 - Second DRAFT NIST Interagency Report (NISTIR) 7628, Smart Grid Cyber Security Strategy and...

    Science.gov (United States)

    2010-04-13

    ... a cyber attack. 2. It is essential that those parts or equipment of the Smart Grid that optimize the...-0143-01] Second DRAFT NIST Interagency Report (NISTIR) 7628, Smart Grid Cyber Security Strategy and... (NIST) seeks comments on the second draft of NISTIR 7628, Smart Grid Cyber Security Strategy and...

  20. A response to: "NIST experts urge caution in use of courtroom evidence presentation method"

    OpenAIRE

    Morrison, Geoffrey Stewart

    2017-01-01

    A press release from the National Institute of Standards and Technology (NIST)could potentially impede progress toward improving the analysis of forensic evidence and the presentation of forensic analysis results in courts in the United States and around the world. "NIST experts urge caution in use of courtroom evidence presentation method" was released on October 12, 2017, and was picked up by the phys.org news service. It argues that, except in exceptional cases, the results of forensic ana...

  1. Further Investigations of NIST Water Sphere Discrepancies

    International Nuclear Information System (INIS)

    Broadhead, B.L.

    2001-01-01

    Measurements have been performed on a family of water spheres at the National Institute of Standards and Technology (NIST) facilities. These measurements are important for criticality safety studies in that, frequently, difficulties have arisen in predicting the reactivity of individually subcritical components assembled in a critical array. It has been postulated that errors in the neutron leakage from individual elements in the array could be responsible for these problems. In these NIST measurements, an accurate determination of the leakage from a fission spectrum, modified by water scattering, is available. Previously, results for 3-, 4-, and 5-in. diam. water-filled spheres, both with and without cadmium covers over the fission chambers, were presented for four fissionable materials: 235 U, 238 U, 237 Np, and 239 Pu. Results were also given for ''dry'' systems, in which the water spheres were drained of water, with the results corresponding to essentially measurements of unmoderated 252 Cf spontaneous-fission neutrons. The calculated-to-experimental (C/E) values ranged from 0.94 to 1.01 for the dry systems and 0.93 to 1.05 for the wet systems, with experimental uncertainties ranging from 1.5 to 1.9%. These results indicated discrepancies that were clearly outside of the experimental uncertainties, and further investigation was suggested. This work updates the previous calculations with a comparison of the predicted C/E values with ENDF/B-V and ENDF/B-VI transport cross sections. Variations in the predicted C/E values that arise from the use of ENDF/B-V, ENDF/B-VI, ENDL92, and LLLDOS for the response fission cross sections are also tabulated. The use of both a 45-group NIST fission spectrum and a continuous-energy fission spectrum for 252 Cf are evaluated. The use of the generalized-linear-least-squares (GLLSM) procedures to investigate the reported discrepancies in the water sphere results for 235 U, 238 U, 239 Pu, and 237 Np is reported herein. These studies

  2. The NIST Step Class Library (Step Into the Future)

    Science.gov (United States)

    1990-09-01

    Figure 6. Excerpt from a STEP exclange file based on the Geometry model 1be NIST STEP Class Libary Page 13 An issue of concern in this...Scheifler, R., Gettys, J., and Newman, P., X Window System: C Library and Protocol Reference. Digital Press, Bedford, Mass, 1988. [Schenck90] Schenck, D

  3. Cold neutron prompt gamma activation analysis at NIST; A progress report

    Energy Technology Data Exchange (ETDEWEB)

    Paul, R L; Lindstrom, R M [National Inst. of Standards and Technology, Gaithersburg, MD (United States). Div. of Inorganic Analytical Research; Vincent, D H [Michigan Univ., Ann Arbor, MI (United States). Dept. of Nuclear Engineering

    1994-05-01

    An instrument for prompt gamma-ray activation analysis is now in operation at the NIST Cold Neutron Research Facility (CNRF). The cold neutron beam is relatively free of contamination by fast neutrons and reactor gamma rays, and the neutron fluence rate is 1.5 x 10 [sup 8] cm [sup -2] x s [sup -1] (thermal equivalent). As a result of a compact target-detector geometry the sensitivity is better by a factor of as much as seven than that obtained with an existing thermal instrument, and hydrogen background is a factor of 50 lower. This instrument was applied to multielement analysis of the Allende meteorite and other materials. (author) 14 refs.; 2 figs.; 1 tab.

  4. Characterization of sampling behavior for multielements in NIST SRM 2703

    International Nuclear Information System (INIS)

    Huang Donghui; Sun Hongchao; Ni Bangfa; Tian Weizhi; Wang Pingsheng; Liu CunXiong; Zhang Guiying; Xiao Caijin; Zhang Haiqing; Zhao Changjun; Zhang Yuanxun

    2011-01-01

    Sampling behavior of multielements for NIST SRM 2703, a marine sediment, was studied with sample sizes from 1 mg down to ng level by a combination of INAA, PIXE and SRXRF. On 1 mg sample size level, sampling behavior for multielements in NIST SRM 2703 and its parent SRM 2702 were comparatively characterized by using INAA combining with Ingamells model. Results showed that sampling uncertainties for 12 elements of both materials were found to be better than 1%, and those of four other elements in SRM 2703 better than in SRM 2702. At sample sizes not able to be accurately weighed (<1 mg), PIXE and SRXRF were used and the effective sample sizes estimated. Sampling uncertainties for nine elements were found to be better than 1% at sample sizes of tenth mg level, and those for six elements better than 10% on ng levels. (author)

  5. Examination of quantitative accuracy of PIXE analysis for atmospheric aerosol particle samples. PIXE analysis of NIST air particulate on filter media

    International Nuclear Information System (INIS)

    Saitoh, Katsumi; Sera, Koichiro

    2005-01-01

    In order to confirm accuracy of the direct analysis of filter samples containing atmospheric aerosol particles collected on a polycarbonate membrane filter by PIXE, we carried out PIXE analysis on a National Institute of Standards and Technology (NIST, USA) air particulate on filter media (SRM 2783). For 16 elements with NIST certified values determined by PIXE analysis - Na, Mg, Al, Si, S, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn and Pb - quantitative values were 80-110% relative to NIST certified values except for Na, Al, Si and Ni. Quantitative values of Na, Al and Si were 140-170% relative to NIST certified values, which were all high, and Ni was 64%. One possible reason why the quantitative values of Na, Al and Si were higher than the NIST certified values could be the difference in the X-ray spectrum analysis method used. (author)

  6. Quantum Information Experiments with Trapped Ions at NIST

    Science.gov (United States)

    Wilson, Andrew

    2015-03-01

    We present an overview of recent trapped-ion quantum information experiments at NIST. Advancing beyond few-qubit ``proof-of-principle'' experiments to the many-qubit systems needed for practical quantum simulation and information processing, without compromising on the performance demonstrated with small systems, remains a major challenge. One approach to scalable hardware development is surface-electrode traps. Micro-fabricated planar traps can have a number of useful features, including flexible electrode geometries, integrated microwave delivery, and spatio-temporal tuning of potentials for ion transport and spin-spin interactions. In this talk we report on a number of on-going investigations with surface traps. Experiments feature a multi-zone trap with closely spaced ions in a triangular arrangement (a first step towards 2D arrays of ions with tunable spin-spin interactions), a scheme for smooth transport through a junction in a 2D structure based on switchable RF potentials, and a micro-fabricated photo-detector integrated into a trap. We also give a progress report on our latest efforts to improve the fidelity of both optical and microwave 2-qubit gates. This work was supported by IARPA, ONR and the NIST Quantum Information Program. The 3-ion and switchable-RF-junction traps were developed in collaboration with Sandia National Laboratory.

  7. Recent applications of nuclear analytical methods to the certification of elemental content in NIST standard reference materials

    International Nuclear Information System (INIS)

    Greenberg, R.R.; Zeisler, R.; Mackey, E.A.

    2006-01-01

    Well-characterized, certified reference materials (CRMs) play an essential role in assuring the quality of analytical measurements. NIST has been producing CRMs, currently called NIST Standard Reference Materials (SRMs), to validate analytical measurements for nearly one hundred years. The predominant mode of certifying inorganic constituents in complex-matrix SRMs is through the use of two critically evaluated, independent analytical techniques at NIST. These techniques should have no significant sources of error in common. The use of nuclear analytical methods in combination with one of the chemically based analytical method at NIST eliminates the possibility of any significant, common error source. The inherent characteristics of the various forms of nuclear analytical methods make them extremely valuable for SRM certification. Instrumental NAA is nondestructive, which eliminates the possibility of any dissolution problems, and often provides homogeneity information. Radiochemical NAA typically provides nearly blank-free determinations of some highly important, but difficult elements at very low levels. Prompt-gamma NAA complements INAA, and provides independent determinations of some key elements. In addition, all significant uncertainty components can be evaluated for these techniques, and we believe these methods can meet all the requirements of a primary method of measurement as defined by ISO and the CCQM. NIST has certified several SRMs using INAA and RNAA as primary methods. In addition, NIST has compared measurements by INAA and PGAA with other primary methods as part of the CCQM intercomparisons of national metrology institutes. Some significant SRMs recently certified for inorganic constituents with contributions from the nuclear analytical methods include: Toxic Substances in Urine (SRM 2670a), Lake Superior Fish Tissue (SRM 1946), Air Particulate on Filter Media (SRM 2783), Inorganics in Marine Sediment (SRM 2702), Sediment for Solid Sampling (Small

  8. Corrections of the NIST Statistical Test Suite for Randomness

    OpenAIRE

    Kim, Song-Ju; Umeno, Ken; Hasegawa, Akio

    2004-01-01

    It is well known that the NIST statistical test suite was used for the evaluation of AES candidate algorithms. We have found that the test setting of Discrete Fourier Transform test and Lempel-Ziv test of this test suite are wrong. We give four corrections of mistakes in the test settings. This suggests that re-evaluation of the test results should be needed.

  9. Covariance methodology applied to 35S disintegration rate measurements by the CIEMAT/NIST method

    International Nuclear Information System (INIS)

    Koskinas, M.F.; Nascimento, T.S.; Yamazaki, I.M.; Dias, M.S.

    2014-01-01

    The Nuclear Metrology Laboratory (LMN) at IPEN is carrying out measurements in a LSC (Liquid Scintillation Counting system), applying the CIEMAT/NIST method. In this context 35 S is an important radionuclide for medical applications and it is difficult to be standardized by other primary methods due to low beta ray energy. The CIEMAT/NIST is a standard technique used by most metrology laboratories in order to improve accuracy and speed up beta emitter standardization. The focus of the present work was to apply the covariance methodology for determining the overall uncertainty in the 35 S disintegration rate. All partial uncertainties involved in the measurements were considered, taking into account all possible correlations between each pair of them. - Highlights: ► 35 S disintegration rate measured in Liquid Scintillator system using CIEMAT/NIST method. ► Covariance methodology applied to the overall uncertainty in the 35 S disintegration rate. ► Monte Carlo simulation was applied to determine 35 S activity in the 4πβ(PC)-γ coincidence system

  10. Supervised and Unsupervised Speaker Adaptation in the NIST 2005 Speaker Recognition Evaluation

    National Research Council Canada - National Science Library

    Hansen, Eric G; Slyh, Raymond E; Anderson, Timothy R

    2006-01-01

    Starting in 2004, the annual NIST Speaker Recognition Evaluation (SRE) has added an optional unsupervised speaker adaptation track where test files are processed sequentially and one may update the target model...

  11. Experimental efforts at NIST towards one-electron ions in circular Rydberg states

    International Nuclear Information System (INIS)

    Tan, Joseph N; Guise, Nicholas D; Brewer, Samuel M

    2011-01-01

    Experimental effort is underway at NIST to enable tests of theory with one-electron ions synthesized in circular Rydberg states from captured bare nuclei. Problematic effects that limit the accuracy of predicted energy levels for low-lying states are vanishingly small for high-angular-momentum (high-L) states; in particular, the nuclear size correction for high-L states is completely negligible for any foreseeable improvement of measurement precision. As an initial step towards realizing such states, highly charged ions are extracted from the NIST electron beam ion trap (EBIT) and steered through the electrodes of a Penning trap. The goal is to capture bare nuclei in the Penning trap for experiments to make one-electron atoms in circular Rydberg states with dipole (E1) transitions in the optical domain accessible to a frequency comb.

  12. DELAMINATION AND XRF ANALYSIS OF NIST LEAD IN PAINT FILM STANDARDS

    Science.gov (United States)

    The objectives of this protocol were to remove the laminate coating from lead paint film standards acquired from NIST by means of surface heating. The average XRF value did not change after removal of the polymer coating suggesting that this protocol is satisfactory for renderin...

  13. Characterization of LANDSAT Panels Using the NIST BRDF Scale from 1100 nm to 2500 nm

    Science.gov (United States)

    Markham, Brian; Tsai, Benjamin K.; Allen, David W.; Cooksey, Catherine; Yoon, Howard; Hanssen, Leonard; Zeng, Jinan; Fulton, Linda; Biggar, Stuart; Markham, Brian

    2010-01-01

    Many earth observing sensors depend on white diffuse reflectance standards to derive scales of radiance traceable to the St Despite the large number of Earth observing sensors that operate in the reflective solar region of the spectrum, there has been no direct method to provide NIST traceable BRDF measurements out to 2500 rim. Recent developments in detector technology have allowed the NIST reflectance measurement facility to expand the operating range to cover the 250 nm to 2500 nm range. The facility has been modified with and additional detector using a cooled extended range indium gallium arsenide (Extended InGaAs) detector. Measurements were made for two PTFE white diffuse reflectance standards over the 1100 nm to 2500 nm region at a 0' incident and 45' observation angle. These two panels will be used to support the OLI calibration activities. An independent means of verification was established using a NIST radiance transfer facility based on spectral irradiance, radiance standards and a diffuse reflectance plaque. An analysis on the results and associated uncertainties will be discussed.

  14. PHYSICS AND SAFETY ANALYSIS FOR THE NIST RESEARCH REACTOR

    International Nuclear Information System (INIS)

    CHENG, L.; HANSON, A.; DIAMOND, D.; XU, J.; CAREW, J.; RORER, D.

    2004-01-01

    Detailed reactor physics and safety analyses have been performed for the 20 MW D 2 O moderated research reactor (NBSR) at the National Institute of Standards and Technology (NIST). The analyses provide an update to the Final Safety Analysis Report (FSAR) and employ state-of-the-art calculational methods. Three-dimensional Monte Carlo neutron and photon transport calculations were performed with the MCNP code to determine the safety parameters for the NBSR. The core depletion and determination of the fuel compositions were performed with MONTEBURNS. MCNP calculations were performed to determine the beginning, middle, and end-of-cycle power distributions, moderator temperature coefficient, and shim safety arm, beam tube and void reactivity worths. The calculational model included a plate-by-plate description of each fuel assembly, axial mid-plane water gap, beam tubes and the tubular geometry of the shim safety arms. The time-dependent analysis of the primary loop was determined with a RELAP5 transient analysis model that includes the pump, heat exchanger, fuel element geometry, and flow channels for both the six inner and twenty-four outer fuel elements. The statistical analysis used to assure protection from critical heat flux (CHF) was performed using a Monte Carlo simulation of the uncertainties contributing to the CHF calculation. The power distributions used to determine the local fuel conditions and margin to CHF were determined with MCNP. Evaluations were performed for the following accidents: (1) the control rod withdrawal startup accident, (2) the maximum reactivity insertion accident, (3) loss-of-flow resulting from loss of electrical power, (4) loss-of-flow resulting from a primary pump seizure, (5) loss-of-flow resulting from inadvertent throttling of a flow control valve, (6) loss-of-flow resulting from failure of both shutdown cooling pumps and (7) misloading of a fuel element. In both the startup and maximum reactivity insertion accidents, the core

  15. The TNO speaker diarization system for NIST RT05s meeting data

    NARCIS (Netherlands)

    Leeuwen, D.A. van

    2006-01-01

    The TNO speaker speaker diarization system is based on a standard BIC segmentation and clustering algorithm. Since for the NIST Rich Transcription speaker dizarization evaluation measure correct speech detection appears to be essential, we have developed a speech activity detector (SAD) as well.

  16. Update of NIST half-life results corrected for ionization chamber source-holder instability

    International Nuclear Information System (INIS)

    Unterweger, M.P.; Fitzgerald, R.

    2014-01-01

    As reported at the ICRM 2011, it was discovered that the source holder used for calibrations in the NIST 4πγ ionization chamber (IC) was not stable. This has affected a large number of half-life measurement results previously reported and used in compilations of nuclear data. Corrections have been made on all of the half-life data based on the assumption that the changes to the ionization chamber response were gradual. The corrections are energy dependent and therefore radionuclide specific. This presentation will review our results and present the recommended changes in half-life values and/or uncertainties. - Highlights: • The NIST half-life data is corrected for sample positioning variations and refitted. • These results are reported and increased errors in the reported values are given. • Longer lived radionuclides are discussed

  17. The AMI speaker diarization system for NIST RT06s meeting data

    NARCIS (Netherlands)

    Leeuwen, D.A. van; Huijbregts, Marijn

    2006-01-01

    We describe the systems submitted to the NIST RT06s evaluation for the Speech Activity Detection (SAD) and Speaker Diarization (SPKR) tasks. For speech activity detection, a new analysis methodology is presented that generalizes the Detection Erorr Tradeoff analysis commonly used in speaker

  18. The AMI speaker diarization system for NIST RT06s meeting data

    NARCIS (Netherlands)

    van Leeuwen, David A.; Huijbregts, M.A.H.

    2007-01-01

    We describe the systems submitted to the NIST RT06s evaluation for the Speech Activity Detection (SAD) and Speaker Diarization (SPKR) tasks. For speech activity detection, a new analysis methodology is presented that generalizes the Detection Erorr Tradeoff analysis commonly used in speaker detection

  19. Planning Document for an NBSR Conversion Safety Analysis Report

    Energy Technology Data Exchange (ETDEWEB)

    Diamond D. J.; Baek J.; Hanson, A.L.; Cheng, L-Y.; Brown, N.; Cuadra, A.

    2013-09-25

    The NIST Center for Neutron Research (NCNR) is a reactor-laboratory complex providing the National Institute of Standards and Technology (NIST) and the nation with a world-class facility for the performance of neutron-based research. The heart of this facility is the National Bureau of Standards Reactor (NBSR). The NBSR is a heavy water moderated and cooled reactor operating at 20 MW. It is fueled with high-enriched uranium (HEU) fuel elements. A Global Threat Reduction Initiative (GTRI) program is underway to convert the reactor to low-enriched uranium (LEU) fuel. This program includes the qualification of the proposed fuel, uranium and molybdenum alloy foil clad in an aluminum alloy, and the development of the fabrication techniques. This report is a planning document for the conversion Safety Analysis Report (SAR) that would be submitted to, and approved by, the Nuclear Regulatory Commission (NRC) before the reactor could be converted.This report follows the recommended format and content from the NRC codified in NUREG-1537, “Guidelines for Preparing and Reviewing Applications for the Licensing of Non-power Reactors,” Chapter 18, “Highly Enriched to Low-Enriched Uranium Conversions.” The emphasis herein is on the SAR chapters that require significant changes as a result of conversion, primarily Chapter 4, Reactor Description, and Chapter 13, Safety Analysis. The document provides information on the proposed design for the LEU fuel elements and identifies what information is still missing. This document is intended to assist ongoing fuel development efforts, and to provide a platform for the development of the final conversion SAR. This report contributes directly to the reactor conversion pillar of the GTRI program, but also acts as a boundary condition for the fuel development and fuel fabrication pillars.

  20. Primary standardization of {sup 152}Eu by 4πβ(LS) - γ (NaI) coincidence counting and CIEMAT-NIST method

    Energy Technology Data Exchange (ETDEWEB)

    Ruzzarin, A., E-mail: aruzzarin@nuclear.ufrj.br [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (LIN/PEN/COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Lab. de Instrumentação Nuclear; Cruz, P.A.L. da; Ferreira Filho, A.L.; Iwahara, A. [Instituto de Radioproteção e Dosimetria (LNMRI/IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. Nacional de Metrologia das Radiações Ionizantes

    2017-07-01

    The 4πβ-γ coincidence counting and CIEMAT/NIST liquid scintillation method were used in the standardization of a solution of {sup 152}Eu. In CIEMAT/NIST method, measurements were performed in a Liquid Scintillation Counter model Wallac 1414. In the 4πβ-γ coincidence counting, the solution was standardized using a coincidence method with 'beta-efficiency extrapolation'. A simple 4πβ-γ coincidence system was used, with acrylic scintillation cell coupled to two coincident photomultipliers at 180° each other and NaI(Tl) detector. The activity concentrations obtained were 156.934 ± 0.722 and 157.403 ± 0.113 kBq/g, respectively, for CIEMAT/NIST and 4πβ-γ coincidence counting measurement methods. (author)

  1. Analysis of the NIST database towards the composition of vulnerabilities in attack scenarios

    NARCIS (Netherlands)

    Nunes Leal Franqueira, V.; van Keulen, Maurice

    The composition of vulnerabilities in attack scenarios has been traditionally performed based on detailed pre- and post-conditions. Although very precise, this approach is dependent on human analysis, is time consuming, and not at all scalable. We investigate the NIST National Vulnerability Database

  2. Establishment of a sensor testbed at NIST for plant productivity monitoring

    Science.gov (United States)

    Allen, D. W.; Hutyra, L.; Reinmann, A.; Trlica, A.; Marrs, J.; Jones, T.; Whetstone, J. R.; Logan, B.; Reblin, J.

    2017-12-01

    Accurate assessments of biogenic carbon fluxes is challenging. Correlating optical signatures to plant activity allows for monitoring large regions. New methods, including solar-induced fluorescence (SIF), promise to provide more timely and accurate estimate of plant activity, but we are still developing a full understanding of the mechanistic leakage between plant assimilation of carbon and SIF. We have initiated a testbed to facilitate the evaluation of sensors and methods for remote monitoring of plant activity at the NIST headquarters. The test bed utilizes a forested area of mature trees in a mixed urban environment. A 1 hectare plot within the 26 hectare forest has been instrumented for ecophysiological measurements with an edge (100 m long) that is persistently monitored with multimodal optical sensors (SIF spectrometers, hyperspectral imagers, thermal infrared imaging, and lidar). This biological testbed has the advantage of direct access to the national scales maintained by NIST of measurements related to both the physical and optical measurements of interest. We offer a description of the test site, the sensors, and preliminary results from the first season of observations for ecological, physiological, and remote sensing based estimates of ecosystem productivity.

  3. Discrepancy of sodium mass fraction determined by INAA in the NIST SRM1547 and SRM1515 reference materials and their certified values

    International Nuclear Information System (INIS)

    Kamenik, Jan; Kucera, Jan

    2015-01-01

    Determination of sodium content in NIST standard reference materials (SRM) SRM 1547 and SRM 1515 in recent years yielded values higher than NIST certified values. Similarly, increased values were published for SRM 1547 by several laboratories, however, published sodium values SRM 1515 are in general in agreement with the certified value. Additional analysis of SRM 1547 and SRM 1515 using NIST SRM 3152a Sodium Standard Solution as a calibrator confirmed increased Na values. Inhomogeneity indicating external contamination of the stock material was not found. Moreover, increased Na value was also determined for freshly opened bottle of SRM 1547 material. Analysis of the historical material A-2 from our archive, which is identical with SRM 1515 and was distributed by NIST prior to the SRM 1515 certification and stored in a polyethylene vial, yielded a value in agreement with the certified value. A hypothesis was formulated that sodium in SRM 1547 and SRM 1515 materials could have been increasing after certification, perhaps due to the release of sodium from the glass bottle. (author)

  4. The (TNO) Speaker Diarization System for NIST Rich Transcription Evaluation 2005 for meeting data

    NARCIS (Netherlands)

    Leeuwen, D.A. van

    2005-01-01

    Abstract. The TNO speaker speaker diarization system is based on a standard BIC segmentation and clustering algorithm. Since for the NIST Rich Transcription speaker dizarization evaluation measure correct speech detection appears to be essential, we have developed a speech activity detector (SAD) as

  5. NIST--Los Alamos racetrack microtron status

    International Nuclear Information System (INIS)

    Wilson, M.A.; Ayres, R.L.; Cutler, R.I.; Debenham, P.H.; Lindstrom, E.R.; Mohr, D.L.; Penner, S.; Rose, J.E.; Young, L.M.

    1988-01-01

    The NIST-Los Alamos Racetrack Microtron (RTM) is designed to deliver a low-emittance electron beam of up to 0.5 mA cw over an energy range of 17 MeV to 185 MeV. Fed by a 5 MeV injector, the RTM contains two 180 degree end magnets that recirculate the beam up to 15 times through a 12 MeV RF linac. The linac, which operates in a standing-wave mode at 2380 MHz, has been tested to nearly full RF power. At present, the injector has undergone beam tests, and the beam transport system is complete through the 12 MeV linac. A temporary beam line has been installed at the exit of one end magnet to measure the beam energy, energy spread, and emittance after one pass through the accelerator. Preliminary results indicate that the accelerated beam energy spread and emittance are within design goals. 4 refs., 7 figs

  6. Concurso NIST. Análisis del concurso (2007-2012)

    OpenAIRE

    Martín Sierra, Marían

    2014-01-01

    El objetivo de este proyecto es dar a conocer el concurso SHA-3, concurso que ha transcurrido durante los últimos años y que ha promovido el Instituto Nacional de Estándares y Tecnología, también conocido como NIST, con el objetivo de encontrar el nuevo algoritmo criptográfico de función resumen SHA-3 que se utilizará de estándar de aquí en adelante. Con este fin se ha realizado un estudio sobre criptografía en general y sobre algunos de los algoritmos criptográficos de func...

  7. Findings and Recommendations from the NIST Workshop on Alternative Fuels and Materials: Biocorrosion.

    Science.gov (United States)

    Mansfield, Elisabeth; Sowards, Jeffrey W; Crookes-Goodson, Wendy J

    2015-01-01

    In 2013, the Applied Chemicals and Materials Division of the National Institute of Standards and Technology (NIST) hosted a workshop to identify and prioritize research needs in the area of biocorrosion. Materials used to store and distribute alternative fuels have experienced an increase in corrosion due to the unique conditions caused by the presence of microbes and the chemistry of biofuels and biofuel precursors. Participants in this workshop, including experts from the microbiological, fuel, and materials communities, delved into the unique materials and chemical challenges that occur with production, transport, and storage of alternative fuels. Discussions focused on specific problems including: a) the changing composition of "drop-in" fuels and the impact of that composition on materials; b) the influence of microbial populations on corrosion and fuel quality; and c) state-of-the-art measurement technologies for monitoring material degradation and biofilm formation.

  8. Reflective Optical Chopper Used in NIST High-Power Laser Measurements

    Directory of Open Access Journals (Sweden)

    Cromer, Chris

    2008-11-01

    Full Text Available For the past ten years, NIST has used high-reflectivity, optical choppers as beamsplitters and attenuators when calibrating the absolute responsivity and response linearity of detectors used with high-power CW lasers. The chopper-based technique has several advantages over the use of wedge-shaped transparent materials (usually crystals often used as beam splitters in this type of measurement system. We describe the design, operation and calibration of these choppers. A comparison between choppers and transparent wedge beampslitters is also discussed.

  9. Aplicación del NFIS (Nist Fingerprint Image Software para la Extracción de Características de Huellas Dactilares Aplicación del NFIS (Nist Fingerprint Image Software para la Extracción de Características de Huellas Dactilares

    Directory of Open Access Journals (Sweden)

    Noé Mosqueda Valadez

    2012-02-01

    Full Text Available Este artículo presenta una descripción acerca de las huellas dactilares y sus características, así como la extracción de puntos característicos de la misma por medio del programa NFIS desarrollado por el NIST (National Institute of Standards and Technology en conjunción con el FBI (Federal Bureau of Investigation, descripción de algunas herramientas, así como un panorama general de un sistema AFAS (Automatic Fingerprint Authentification System y de un sistema AFIS (Automatic Fingerprint Identification System. This paper presents a description about the fingerprints and its characteristics, as well as the extraction of their characteristic points by means of the application of the program NFIS (NIST Fingerprint Image Software developed by the NIST (National Institute of Standards and Technology in conjunction with the FBI (Federal Bureau of Investigation, the description of some tools, as well as a general view of a system AFAS (Automatic Fingerprint Authentification System and of a system AFIS (Automatic Fingerprint Identification System.

  10. Improving iodine homogeneity in NIST SRM 1548a Typical Diet by cryogenic grinding

    Czech Academy of Sciences Publication Activity Database

    Kučera, Jan; Kameník, Jan

    2015-01-01

    Roč. 20, č. 3 (2015), s. 189-194 ISSN 0949-1775 R&D Projects: GA ČR(CZ) GBP108/12/G108; GA MŠk LM2011019 Institutional support: RVO:61389005 Keywords : Iodine * reference material * NIST SRM 1548a * cryogenic grinding * homogeneity Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 1.010, year: 2015

  11. Evaluation of the sensitivity of the 'Wiley registry of tandem mass spectral data, MSforID' with MS/MS data of the 'NIST/NIH/EPA mass spectral library'.

    Science.gov (United States)

    Oberacher, Herbert; Whitley, Graeme; Berger, Bernd

    2013-04-01

    Tandem mass spectral libraries are versatile tools for small molecular identification finding application in forensic science, doping control, drug monitoring, food and environmental analysis, as well as metabolomics. Two important libraries are the 'Wiley Registry of Tandem Mass Spectral Data, MSforID' (Wiley Registry MSMS) and the collection of MS/MS spectra part of the 2011 edition of the 'NIST/NIH/EPA Mass Spectral Library' (NIST 11 MSMS). Herein, the sensitivity and robustness of the Wiley Registry MSMS were evaluated using spectra extracted from the NIST 11 MSMS library. The sample set was found to be heterogeneous in terms of mass spectral resolution, type of CID, as well as applied collision energies. Nevertheless, sensitive compound identification with a true positive identification rate ≥95% was possible using either the MSforID Search program or the NIST MS Search program 2.0g for matching. To rate the performance of the Wiley Registry MSMS, cross-validation experiments were repeated using subcollections of NIST 11 MSMS as reference library and spectra extracted from the Wiley Registry MSMS as positive controls. Unexpectedly, with both search algorithms tested, correct results were obtained in less than 88% of cases. We examined possible causes for the results of the cross validation study. The large number of precursor ions represented by a single tandem mass spectrum only was identified as the basic cause for the comparably lower sensitivity of the NIST library. Copyright © 2013 John Wiley & Sons, Ltd.

  12. Liquid Scintillation counting Standardization of 22 NaCl by the CIEMAT/NIST method

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Grau Carles, A.; Grau Malonda, A.

    1995-09-01

    We describe a procedure for preparing a stable solution of ''22 NaCl for liquid scintillation counting and its counting stability and spectral evolution in Insta-Gel''R is studied. The solution has been standardised in terms of activity concentration by the CIEMAT/NIST method with discrepancies between experimental and computed efficiencies lower than 0.4/% and an overall uncertainty of 0.35%

  13. 76 FR 27305 - Proposed Information Collection; Comment Request; the NIST Summer Institute for Middle School...

    Science.gov (United States)

    2011-05-11

    ...) programs designed to support middle school science teachers to participate in hands-on workshops, lectures... Gaithersburg, Maryland. The workshops provide teachers with instructional information and ideas to use in their teaching, and emphasize the measurement science done at NIST. The Program provides a world-class...

  14. Comparison of elemental quantity by PIXE and ICP-MS and/or ICP-AES for NIST standards

    International Nuclear Information System (INIS)

    Saitoh, K.; Sera, K.; Gotoh, T.; Nakamura, M.

    2002-01-01

    Urban particulate matter (SRM 1648), Buffalo River sediment (SRM 2704) and pine needle (SRM 1575) standard reference materials prepared by the National Institute of Standards and Technology (NIST, USA) were analyzed by three multi-element analysis methods, i.e., particle induced X-ray emission (PIXE), inductively coupled plasma-mass spectrometry (ICP-MS) and inductively coupled plasma-atomic emission spectrometry (ICP-AES); values determined by those analysis methods were compared with certified and/or non-certified values of NIST samples. Values determined by PIXE were 70-120% relative to certified and/or non-certified values of NIST samples except for Co in the urban particulate matter, for V and Co in Buffalo River sediment and for Ni and Br in the pine needles samples. In particular, Al, K, Ca, Cr, Mn, Fe, Cu, Zn and Pb were 85-110% in all samples. On the other hand, Na and Fe values determined by ICP-MS were very much different from the certified values in all samples, but the other elements were 70-120%. As for ICP-AES, all elements except for Na were 80-100% in all samples. Comparing the values determined by PIXE and those determined by ICP-MS and/or ICP-AES, there was a slight difference between the samples, but the range was 75-120% except for Na, V, Fe and Co determined by ICP-MS and Na determined by ICP-AES, which was generally consistent with PIXE

  15. Exploring a Black Body Source as an Absolute Radiometric Calibration Standard and Comparison with a NIST Traced Lamp Standard

    Science.gov (United States)

    Green, Robert O.; Chrien, Thomas; Sarture, Chuck

    2001-01-01

    Radiometric calibration of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) is required for the scientific research and application objectives pursued with the spectroscopic measurements. Specifically calibration is required for: inter-comparison of AVIRIS data measured at different locations and at different times; analysis of AVIRIS data with data measured by other instruments; and analysis of AVIRIS data in conjunction with computer models. The primary effect of radiometric calibration is conversion of AVIRIS instrument response values (digitized numbers, or DN) to units of absolute radiance. For example, a figure shows the instrument response spectrum measured by AVIRIS over a portion of Rogers Dry Lake, California, and another figure shows the same spectrum calibrated to radiance. Only the calibrated spectrum may be quantitatively analyzed for science research and application objectives. Since the initial development of the AVIRIS instrument-radiometric calibration has been based upon a 1000-W irradiance lamp with a calibration traced to the National Institute of Standards and Technology (NIST). There are several advantages to this irradiance-lamp calibration approach. First, the considerable effort of NIST backs up the calibration. Second, by changing the distance to the lamp, the output can closely span the radiance levels measured by AVIRIS. Third, this type of standard is widely used. Fourth, these calibrated lamps are comparatively inexpensive. Conversely, there are several disadvantages to this approach as well. First, the lamp is not a primary standard. Second, the lamp output characteristics may change in an unknown manner through time. Third, it is difficult to assess, constrain, or improve the calibration uncertainty delivered with the lamp. In an attempt to explore the effect and potentially address some of these disadvantages a set of analyses and measurements comparing an irradiance lamp with a black-body source have been completed

  16. Liquid Scintillation Counting Standardization of 22NaCl by te CIEMAT/NIST method

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Grau Carles, A.; Grau Malonda, A.

    1995-01-01

    We describe a procedure for preparing a stable solution of ''22NaCl for liquid scintillation counting and its counting stability and spectral evolution in Insta-Gel''R is studied. The solution has been standardised in terms of activity concentration by the CIEMAT/NIST method with discrepancies between experimental and computed efficiencies lower than 0.4 % and an overall uncertainty of 0.35 %. (Author) 4 refs

  17. Liquid Scintillation Counting Standardization of {sup 2}2NaCl by te CIEMAT/NIST method; Calibracion por Centelleo Liquido del ''22NaCl, mediante el metodo CIEMAT/NIST

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Barquero, L.; Grau Carles, A.; Grau Malonda, A.

    1995-07-01

    We describe a procedure for preparing a stable solution of ''22NaCl for liquid scintillation counting and its counting stability and spectral evolution in Insta-Gel''R is studied. The solution has been standardised in terms of activity concentration by the CIEMAT/NIST method with discrepancies between experimental and computed efficiencies lower than 0.4 % and an overall uncertainty of 0.35 %. (Author) 4 refs.

  18. Advancing Smart Grid Interoperability and Implementing NIST's Interoperability Roadmap

    Energy Technology Data Exchange (ETDEWEB)

    Basso,T.; DeBlasio, R.

    2010-04-01

    The IEEE American National Standards project P2030TM addressing smart grid interoperability and the IEEE 1547 series of standards addressing distributed resources interconnection with the grid have been identified in priority action plans in the Report to NIST on the Smart Grid Interoperability Standards Roadmap. This paper presents the status of the IEEE P2030 development, the IEEE 1547 series of standards publications and drafts, and provides insight on systems integration and grid infrastructure. The P2030 and 1547 series of standards are sponsored by IEEE Standards Coordinating Committee 21.

  19. Progress in Primary Acoustic Thermometry at NIST: 273 K to 505 K

    Science.gov (United States)

    Strouse, G. F.; Defibaugh, D. R.; Moldover, M. R.; Ripple, D. C.

    2003-09-01

    The NIST Acoustic Thermometer determines the thermodynamic temperature by measuring the speed of sound of argon in a spherical cavity. We obtained the thermodynamic temperature of three fixed points on the International Temperature Scale of 1990: the melting point of gallium [T(Ga) = 302.9146 K] and the freezing points of indium [T(In) = 429.7485 K] and tin [T(Sn) = 505.078 K]. The deviations of thermodynamic temperature from the ITS-90 defined temperatures are T - T90 = (4.7 ± 0.6) mK at T(Ga) , T - T90 = (8.8 ± 1.5) mK at T(In) , and T - T90 = (10.7 ± 3.0) mK at T(Sn) , where the uncertainties are for a coverage factor of k = 1. Our results at T(In) and T(Sn) reduce the uncertainty of T - T90 by a factor of two in this range. Both T - T90 at T(Ga) and the measured thermal expansion of the resonator between the triple point of water and T(Ga) are in excellent agreement with the 1992 determination at NIST. The dominant uncertainties in the present data come from frequency-dependent and time-dependent crosstalk between the electroacoustic transducers. We plan to reduce these uncertainties and extend this work to 800 K.

  20. 76 FR 67418 - Request for Comments on NIST Special Publication 500-293, US Government Cloud Computing...

    Science.gov (United States)

    2011-11-01

    ...-1659-01] Request for Comments on NIST Special Publication 500-293, US Government Cloud Computing... Publication 500-293, US Government Cloud Computing Technology Roadmap, Release 1.0 (Draft). This document is... (USG) agencies to accelerate their adoption of cloud computing. The roadmap has been developed through...

  1. Rigorous quantitative elemental microanalysis by scanning electron microscopy/energy dispersive x-ray spectrometry (SEM/EDS) with spectrum processing by NIST DTSA-II

    Science.gov (United States)

    Newbury, Dale E.; Ritchie, Nicholas W. M.

    2014-09-01

    Quantitative electron-excited x-ray microanalysis by scanning electron microscopy/silicon drift detector energy dispersive x-ray spectrometry (SEM/SDD-EDS) is capable of achieving high accuracy and high precision equivalent to that of the high spectral resolution wavelength dispersive x-ray spectrometer even when severe peak interference occurs. The throughput of the SDD-EDS enables high count spectra to be measured that are stable in calibration and resolution (peak shape) across the full deadtime range. With this high spectral stability, multiple linear least squares peak fitting is successful for separating overlapping peaks and spectral background. Careful specimen preparation is necessary to remove topography on unknowns and standards. The standards-based matrix correction procedure embedded in the NIST DTSA-II software engine returns quantitative results supported by a complete error budget, including estimates of the uncertainties from measurement statistics and from the physical basis of the matrix corrections. NIST DTSA-II is available free for Java-platforms at: http://www.cstl.nist.gov/div837/837.02/epq/dtsa2/index.html).

  2. Assessment of stability of trace elements in two natural matrix environmental standard reference materials. NIST-SRM 1547 Peach leaves and NIST-SRM 1566a Oyster Tissue

    International Nuclear Information System (INIS)

    Mackey, E.A.; Spatz, R.O.

    2009-01-01

    The NIST program for environmental Standard Reference Materials (SRM) includes materials covering a range of matrices, mass fraction values and analytes. For many SRMs, mass fraction data are accumulated, incidentally, over time, as these are used routinely for quality assurance purposes. Although these are not formal stability studies, data generated may be useful in assessing stability. To evaluate the potential for assessing material stability from incidental use of SRMs, results of neutron activation analysis performed from 1992 through 2008 were compiled for SRM 1547 Peach Leaves and SRM 1566a Oyster Tissue. Results indicate that incidental use of SRMs yields useful information on SRM stability. (author)

  3. SU-F-I-13: Correction Factor Computations for the NIST Ritz Free Air Chamber for Medium-Energy X Rays

    International Nuclear Information System (INIS)

    Bergstrom, P

    2016-01-01

    Purpose: The National Institute of Standards and Technology (NIST) uses 3 free-air chambers to establish primary standards for radiation dosimetry at x-ray energies. For medium-energy × rays, the Ritz free-air chamber is the main measurement device. In order to convert the charge or current collected by the chamber to the radiation quantities air kerma or air kerma rate, a number of correction factors specific to the chamber must be applied. Methods: We used the Monte Carlo codes EGSnrc and PENELOPE. Results: Among these correction factors are the diaphragm correction (which accounts for interactions of photons from the x-ray source in the beam-defining diaphragm of the chamber), the scatter correction (which accounts for the effects of photons scattered out of the primary beam), the electron-loss correction (which accounts for electrons that only partially expend their energy in the collection region), the fluorescence correction (which accounts for ionization due to reabsorption ffluorescence photons and the bremsstrahlung correction (which accounts for the reabsorption of bremsstrahlung photons). We have computed monoenergetic corrections for the NIST Ritz chamber for the 1 cm, 3 cm and 7 cm collection plates. Conclusion: We find good agreement with other’s results for the 7 cm plate. The data used to obtain these correction factors will be used to establish air kerma and it’s uncertainty in the standard NIST x-ray beams.

  4. SU-F-I-13: Correction Factor Computations for the NIST Ritz Free Air Chamber for Medium-Energy X Rays

    Energy Technology Data Exchange (ETDEWEB)

    Bergstrom, P [National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, MD 20899 (United States)

    2016-06-15

    Purpose: The National Institute of Standards and Technology (NIST) uses 3 free-air chambers to establish primary standards for radiation dosimetry at x-ray energies. For medium-energy × rays, the Ritz free-air chamber is the main measurement device. In order to convert the charge or current collected by the chamber to the radiation quantities air kerma or air kerma rate, a number of correction factors specific to the chamber must be applied. Methods: We used the Monte Carlo codes EGSnrc and PENELOPE. Results: Among these correction factors are the diaphragm correction (which accounts for interactions of photons from the x-ray source in the beam-defining diaphragm of the chamber), the scatter correction (which accounts for the effects of photons scattered out of the primary beam), the electron-loss correction (which accounts for electrons that only partially expend their energy in the collection region), the fluorescence correction (which accounts for ionization due to reabsorption ffluorescence photons and the bremsstrahlung correction (which accounts for the reabsorption of bremsstrahlung photons). We have computed monoenergetic corrections for the NIST Ritz chamber for the 1 cm, 3 cm and 7 cm collection plates. Conclusion: We find good agreement with other’s results for the 7 cm plate. The data used to obtain these correction factors will be used to establish air kerma and it’s uncertainty in the standard NIST x-ray beams.

  5. Dissemination of 3D Visualizations of Complex Function Data for the NIST Digital Library of Mathematical Functions

    Directory of Open Access Journals (Sweden)

    Qiming Wang

    2007-03-01

    Full Text Available The National Institute of Standards and Technology (NIST is developing a digital library to replace the widely used National Bureau of Standards Handbook of Mathematical Functions published in 1964. The NIST Digital Library of Mathematical Functions (DLMF will include formulas, methods of computation, references, and links to software for over forty functions. It will be published both in hardcopy format and as a website featuring interactive navigation, a mathematical equation search, 2D graphics, and dynamic interactive 3D visualizations. This paper focuses on the development and accessibility of the 3D visualizations for the digital library. We examine the techniques needed to produce accurate computations of function data, and through a careful evaluation of several prototypes, we address the advantages and disadvantages of using various technologies, including the Virtual Reality Modeling Language (VRML, interactive embedded graphics, and video capture to render and disseminate the visualizations in an environment accessible to users on various platforms.

  6. Visualizing Magnetic domain of Electric Steel using Grating Interferometer at NG6 of NIST

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Ju; Oh, Oh Sung; Lee, Se Ho; Kim, Dae Seung; Lee, Seung Wook [Pusan National University, Busan (Korea, Republic of); Kim, Jong Yul [KAERI, Daejeon (Korea, Republic of); Kwon, Oh Yeoul [Pohang Iron and Steel Company, Pohang (Korea, Republic of); Hussey, D. S.; Jacobson, D. L.; Lamannad, J. M. [NIST, Gaithersburg (United States)

    2016-05-15

    The Grating Interferometer is one of new imaging techniques provides improved contrast images, Phase Contrast Image and Dark-Field Image, which have never been seen before by conventional radiography. Neutron Dark-Field Imaging (NDFI) suggests new approach for material science providing the scattering image caused by the micro-structure of object. We attracted to the application of NDFI for material science, the electric steel which produce magnetic scattering information especially. In this study, we developed 1 dimensional gratings using gadox filling method to make the Talbot-Lau Interferometer (TLI). The experiment was conducted at cold neutron imaging facility NG6 of National Institute of Standards and Technologies, NIST. We confirmed that the 3 order Talbot-Lau type of neutron grating interferometer which is composed of gratings made by gadox filling method is well operated at cold neutron imaging beamline. NDFI is definitely powerful visualizing tool for material science, especially magnetic materials. In further study, we will research electric steel more in realistic conditions when it is worked as a component of electric motor.

  7. NIST ThermoData Engine: Extension to Solvent Design and Propagation of Uncertainties for Process Simulation

    DEFF Research Database (Denmark)

    Diky, Vladimir; Chirico, Robert D.; Muzny, Chris

    ThermoData Engine (TDE, NIST Standard Reference Databases 103a and 103b) is the first product that implements the concept of Dynamic Data Evaluation in the fields of thermophysics and thermochemistry, which includes maintaining the comprehensive and up-to-date database of experimentally measured ...... uncertainties, curve deviations, and inadequacies of the models. Uncertainty analysis shows relative contributions to the total uncertainty from each component and pair of components....

  8. Homogeneity and evaluation of the new NIST leaf certified reference materials

    International Nuclear Information System (INIS)

    Becker, D.A.

    1990-01-01

    The NIST has produced and is in the process of certifying two new leaf CRMs, SRM1515 Apple Leaves and SRM 1547 Peach Leaves, as replacements for the no longer available NBS Orchard Leaves and the almost depleted Citrus Leaves. These two new materials have been processed and are being thoroughly evaluated and should provide the most advanced natural matrix botanical trace-element reference materials available. Caution should be used in determining a basis weight (drying) for these CRMs because of their very fine particle size. Homogeneity has been established by instrumental neutron activation analysis on both leaf materials for five elements, to date, to better than 1.5% (1 s) for 100-mg sample sizes

  9. CERT (registered trademark) Resilience Management Model (CERT (registered trademark)-RMM) V1.1: NIST Special Publication Crosswalk Version 2

    Science.gov (United States)

    2014-06-01

    27000 series, COBIT, the British Standards Institution’s BS 25999, and ISO 24762  includes quantitative process measurements that can be used to...the NIST special publications 800 series, the International Organization for Standards ( ISO ) and International Electrotechnical Commission (IEC

  10. Intelligent Processing Equipment Research and Development Programs of the Department of Commerce

    Science.gov (United States)

    Simpson, J. A.

    1992-01-01

    The intelligence processing equipment (IPE) research and development (R&D) programs of the Department of Commerce are carried out within the National Institute of Standards and Technology (NIST). This institute has had work in support of industrial productivity as part of its mission since its founding in 1901. With the advent of factory automation these efforts have increasingly turned to R&D in IPE. The Manufacturing Engineering Laboratory (MEL) of NIST devotes a major fraction of its efforts to this end while other elements within the organization, notably the Material Science and Engineering Laboratory, have smaller but significant programs. An inventory of all such programs at NIST and a representative selection of projects that at least demonstrate the scope of the efforts are presented.

  11. Liquid scintillation counting standardization of 125I in organic and inorganic samples by the CIEMAT/NIST method; Calibracion por centelleo liquido del 125I en muestras inorganicas y organicas, mediante el metodo CIEMAT/NIST

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Barquero, L.; Grau Malonda, A.; Los Arcos Merino, J. M.; Grau Carles, A.

    1994-07-01

    The liquid scintillation counting standardization of organic and inorganic samples of ''I25I by the CIEMAT/NIST method using five different scintillators is described. The discrepancies between experimental and computed efficiencies are lower than 1.4% and 1.7%, for inorganic and organic samples, respectively, in the interval 421-226 of quenching parameter. Both organic and inorganic solutions have been standardized in terms of activity concentration to an overall uncertainty of 0.76%. (Author) 14 refs.

  12. 41Ca standardization by the CIEMAT/NIST LSC method

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Los Arcos, J.M.

    1996-01-01

    A procedure for the liquid scintillation counting standardization of the electron-capture nuclide 41 Ca has been successfully developed and applied with 41 CaCl 2 and 41 Ca-(HDEHP) n samples synthesized in the laboratory from 41 CaCO 3 supplied by Oak Ridge National Laboratory. Six scintillators were tested: the organic samples were stable in toluene-alcohol, Ultima-Gold TM and HiSafe III TM for 30 d, whereas the inorganic samples were only stable in toluene-alcohol and HiSafe III TM for the same period of time. Despite of the low counting efficiencies (1%-13%) due to the very low-energy of less than 3.6 keV of the X-rays and Auger electrons of 41 Ca, the stable samples were standardized by the CIEMAT/NIST method to a combined uncertainty of 2.4% over a range of figures of merit of 1.75 to 7.25 ( 3 H equivalent efficiency of 40% to 7%). (orig.)

  13. Experimental characterization of the Advanced Liquid Hydrogen Cold Neutron Source spectrum of the NBSR reactor at the NIST Center for Neutron Research

    Science.gov (United States)

    Cook, J. C.; Barker, J. G.; Rowe, J. M.; Williams, R. E.; Gagnon, C.; Lindstrom, R. M.; Ibberson, R. M.; Neumann, D. A.

    2015-08-01

    The recent expansion of the National Institute of Standards and Technology (NIST) Center for Neutron Research facility has offered a rare opportunity to perform an accurate measurement of the cold neutron spectrum at the exit of a newly-installed neutron guide. Using a combination of a neutron time-of-flight measurement, a gold foil activation measurement, and Monte Carlo simulation of the neutron guide transmission, we obtain the most reliable experimental characterization of the Advanced Liquid Hydrogen Cold Neutron Source brightness to date. Time-of-flight measurements were performed at three distinct fuel burnup intervals, including one immediately following reactor startup. Prior to the latter measurement, the hydrogen was maintained in a liquefied state for an extended period in an attempt to observe an initial radiation-induced increase of the ortho (o)-hydrogen fraction. Since para (p)-hydrogen has a small scattering cross-section for neutron energies below 15 meV (neutron wavelengths greater than about 2.3 Å), changes in the o- p hydrogen ratio and in the void distribution in the boiling hydrogen influence the spectral distribution. The nature of such changes is simulated with a continuous-energy, Monte Carlo radiation-transport code using 20 K o and p hydrogen scattering kernels and an estimated hydrogen density distribution derived from an analysis of localized heat loads. A comparison of the transport calculations with the mean brightness function resulting from the three measurements suggests an overall o- p ratio of about 17.5(±1) % o- 82.5% p for neutron energies<15 meV, a significantly lower ortho concentration than previously assumed.

  14. Experimental characterization of the Advanced Liquid Hydrogen Cold Neutron Source spectrum of the NBSR reactor at the NIST Center for Neutron Research

    Energy Technology Data Exchange (ETDEWEB)

    Cook, J.C.; Barker, J.G.; Rowe, J.M.; Williams, R.E. [NIST Center for Neutron Research, National Institute of Standards and Technology, 100 Bureau Drive, Mail Stop 6100, Gaithersburg, MD 20899-6100 (United States); Gagnon, C. [Department of Materials Science and Engineering, University of Maryland, College Park, MD 20742 (United States); Lindstrom, R.M. [Scientist Emeritus, Chemical Sciences Division, National Institute of Standards and Technology, 100 Bureau Drive, Mail Stop 8395, Gaithersburg, MD 20899-8395 (United States); Ibberson, R.M.; Neumann, D.A. [NIST Center for Neutron Research, National Institute of Standards and Technology, 100 Bureau Drive, Mail Stop 6100, Gaithersburg, MD 20899-6100 (United States)

    2015-08-21

    The recent expansion of the National Institute of Standards and Technology (NIST) Center for Neutron Research facility has offered a rare opportunity to perform an accurate measurement of the cold neutron spectrum at the exit of a newly-installed neutron guide. Using a combination of a neutron time-of-flight measurement, a gold foil activation measurement, and Monte Carlo simulation of the neutron guide transmission, we obtain the most reliable experimental characterization of the Advanced Liquid Hydrogen Cold Neutron Source brightness to date. Time-of-flight measurements were performed at three distinct fuel burnup intervals, including one immediately following reactor startup. Prior to the latter measurement, the hydrogen was maintained in a liquefied state for an extended period in an attempt to observe an initial radiation-induced increase of the ortho (o)-hydrogen fraction. Since para (p)-hydrogen has a small scattering cross-section for neutron energies below 15 meV (neutron wavelengths greater than about 2.3 Å), changes in the o- p hydrogen ratio and in the void distribution in the boiling hydrogen influence the spectral distribution. The nature of such changes is simulated with a continuous-energy, Monte Carlo radiation-transport code using 20 K o and p hydrogen scattering kernels and an estimated hydrogen density distribution derived from an analysis of localized heat loads. A comparison of the transport calculations with the mean brightness function resulting from the three measurements suggests an overall o- p ratio of about 17.5(±1) % o- 82.5% p for neutron energies<15 meV, a significantly lower ortho concentration than previously assumed.

  15. Preparation and LSC standardization of ''89 Sr (DNP) using the CIEMAT/NIST method

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Arcos Merino, J.M. Los; Grau Malonda, A.

    1994-01-01

    A procedure for preparation of liquid scintillation counting samples of the strontium DNP complex, labelled with ''89 Sr, is described. The chemical quench, the counting stability and spectral evolution of this compound is studied in six scintillators, Toluene, Toluene-alcohol, Dioxane-naphthalene, HiSafe II, Ultima-Gold and Instagel. The liquid scintillation standardization of ''89Sr-DNP by the CIEMAT/NIST method, using Hisafe II and Ultima-Gold scintillators, has been carried out. The discrepancies between experimental and computed efficiencies are lower than 0.38% and 0.48%, respectively. The solution has been standardized in terms of activity concentration to an overall uncertainty of 0.38%. (Author)

  16. Update of NIST half-life results corrected for ionization chamber source-holder instability.

    Science.gov (United States)

    Unterweger, M P; Fitzgerald, R

    2014-05-01

    As reported at the ICRM 2011, it was discovered that the source holder used for calibrations in the NIST 4πγ ionization chamber (IC) was not stable. This has affected a large number of half-life measurement results previously reported and used in compilations of nuclear data. Corrections have been made on all of the half-life data based on the assumption that the changes to the ionization chamber response were gradual. The corrections are energy dependent and therefore radionuclide specific. This presentation will review our results and present the recommended changes in half-life values and/or uncertainties. © 2013 Published by Elsevier Ltd.

  17. Preparation and LSC Standardization of ''89Sr (DNP) Using the CIEMAT/NIST Method

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Los Arcos Merino, J. M.; Grau Malonda, A.

    1994-01-01

    A procedure for preparation of liquid scintillation counting samples of the strontium DNP complex, labelled with ''89Sr, is described, the chemical quench, the counting stability and spectral evolution of this compound is studied in six scintillators, Toluene, Toluene-alcohol, Dioxane-naphthalene, HiSafe II, Ultima- Gold and Instagel. The liquid scintillation standardization of 89Sr-DNP by the CIEMAT/NIST method, using HiSafe II and Ultima-Gold scintillators, has been carried out. The discrepancies between experimental and computed efficiencies are lower than 0.38% and 0.48%, respectively. The solution has been standardized in terms of activity concentration to an overall uncertainty of 0,38%. (Author) 10 refs

  18. Simulation evaluation of NIST air-kerma rate calibration standard for electronic brachytherapy.

    Science.gov (United States)

    Hiatt, Jessica R; Rivard, Mark J; Hughes, H Grady

    2016-03-01

    Dosimetry for the model S700 50 kV electronic brachytherapy (eBT) source (Xoft, Inc., a subsidiary of iCAD, San Jose, CA) was simulated using Monte Carlo (MC) methods by Rivard et al. ["Calculated and measured brachytherapy dosimetry parameters in water for the Xoft Axxent x-ray source: An electronic brachytherapy source," Med. Phys. 33, 4020-4032 (2006)] and recently by Hiatt et al. ["A revised dosimetric characterization of the model S700 electronic brachytherapy source containing an anode-centering plastic insert and other components not included in the 2006 model," Med. Phys. 42, 2764-2776 (2015)] with improved geometric characterization. While these studies examined the dose distribution in water, there have not previously been reports of the eBT source calibration methods beyond that recently reported by Seltzer et al. ["New national air-kerma standard for low-energy electronic brachytherapy sources," J. Res. Natl. Inst. Stand. Technol. 119, 554-574 (2014)]. Therefore, the motivation for the current study was to provide an independent determination of air-kerma rate at 50 cm in air K̇air(d=50 cm) using MC methods for the model S700 eBT source. Using CAD information provided by the vendor and disassembled sources, an MC model was created for the S700 eBT source. Simulations were run using the mcnp6 radiation transport code for the NIST Lamperti air ionization chamber according to specifications by Boutillon et al. ["Comparison of exposure standards in the 10-50 kV x-ray region," Metrologia 5, 1-11 (1969)], in air without the Lamperti chamber, and in vacuum without the Lamperti chamber. K̇air(d=50 cm) was determined using the *F4 tally with NIST values for the mass energy-absorption coefficients for air. Photon spectra were evaluated over 2 π azimuthal sampling for polar angles of 0° ≤ θ ≤ 180° every 1°. Volume averaging was averted through tight radial binning. Photon energy spectra were determined over all polar angles in both air and vacuum using

  19. The NIST NBSR and Cold Neutron Research Facility

    Energy Technology Data Exchange (ETDEWEB)

    Rush, J.J. [National Inst. of Standards and Technology, Guthersburg, MD (United States)

    1994-12-31

    The 20 MW Neutron Beam Split-Core Reactor (NBSR) has nine radial thermal beam tubes, and a large, highly accessible (35cm) cold source serving an extensive network of eight guide tubes. In operation or under construction are twenty-five neutron beam instruments (20 for neutron scattering) and about a dozen other facilities for neutron trace analysis, dosimetry and irradiation. The 6 x 15cm cold neutron guides are coated with {sup 58}Ni, and the last three being installed this fall are coated top and bottom with supermirrors for further increases in intensity. The new semi-spherical liquid hydrogen source will be described, along with the eight scattering instruments (reflectometry, SANS and high-resolution spectroscopy) which have, or will have, an extensive use in biological research. These instruments will likely provide the best overall capability in the U.S. for the next decade for a number of applications in biomolecular structure and dynamics.

  20. Liquid scintillation counting standardization of ''125 I in organic and inorganic samples by the CIEMAT/NIST method

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Grau Malonda, A.; Los Arcos Merino, J.M.; Grau Carles, A.

    1994-01-01

    The liquid scintillation counting standardization of organic and inorganic samples of ''125 I by the CIEMAT/NIST method using five different scintillators is described. The discrepancies between experimental and computed efficiencies are lower than 1.4% and 1.7%, for inorganic and organic samples, respectively, in the interval 421-226 of quenching parameter. Both organic and inorganic solutions have been standardized in terms of activity concentration to an overall uncertainty of 0.76%

  1. Ultra-low level plutonium isotopes in the NIST SRM 4355A (Peruvian Soil-1)

    International Nuclear Information System (INIS)

    Inn, Kenneth G.W.; LaRosa, Jerome; Nour, Svetlana; Brooks, George; LaMont, Steve; Steiner, Rob; Williams, Ross; Patton, Brad; Bostick, Debbie; Eiden, Gregory; Petersen, Steve; Douglas, Matthew; Beals, Donna; Cadieux, James; Hall, Greg; Goldberg, Steve; Vogt, Stephan

    2009-01-01

    For more than 20 years, countries and their agencies which monitor radionuclide discharge sites and storage facilities have relied on the National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 4355 Peruvian Soil. Its low fallout contamination makes it an ideal soil blank for measurements associated with terrestrial-pathway-to-man studies. Presently, SRM 4355 is out of stock, and a new batch of the Peruvian soil is currently under development as future NIST SRM 4355A. Both environmental radioanalytical laboratories and mass spectrometry communities will benefit from the use of this SRM. The former must assess their laboratory procedural contamination and measurement detection limits by measurement of blank sample material. The Peruvian Soil is so low in anthropogenic radionuclide content that it is a suitable virtual blank. On the other hand, mass spectrometric laboratories have high sensitivity instruments that are capable of quantitative isotopic measurements at low plutonium levels in the SRM 4355 (first Peruvian Soil SRM) that provided the mass spectrometric community with the calibration, quality control, and testing material needed for methods development and legal defensibility. The quantification of the ultra-low plutonium content in the SRM 4355A was a considerable challenge for the mass spectrometric laboratories. Careful blank control and correction, isobaric interferences, instrument stability, peak assessment, and detection assessment were necessary. Furthermore, a systematic statistical evaluation of the measurement results and considerable discussions with the mass spectroscopy metrologists were needed to derive the certified values and uncertainties. The one sided upper limit of the 95% tolerance with 95% confidence for the massic 239 Pu content in SRM 4355A is estimated to be 54,000 atoms/g.

  2. Liquid scintillation counting standardization of 125I in organic and inorganic samples by the CIEMAT/NIST method

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Grau Malonda, A.; Los Arcos Merino, J. M.; Grau Carles, A.

    1994-01-01

    The liquid scintillation counting standardization of organic and inorganic samples of ''I25I by the CIEMAT/NIST method using five different scintillators is described. The discrepancies between experimental and computed efficiencies are lower than 1.4% and 1.7%, for inorganic and organic samples, respectively, in the interval 421-226 of quenching parameter. Both organic and inorganic solutions have been standardized in terms of activity concentration to an overall uncertainty of 0.76%. (Author) 14 refs

  3. Activity measurements of the radionuclide 109Cd for the PTB, Germany and the NIST, USA in the ongoing comparison BIPM.RI(II)-K1.Cd-109

    International Nuclear Information System (INIS)

    Ratel, G.; Michotte, C.; Janssen, H.; Kossert, K.; Lucas, L.; Karam, L.

    2005-01-01

    In 2004, the Physikalisch-Technische Bundesanstalt (PTB, Germany) and the National Institute of Standards and Technology (NIST, USA) each submitted one sample of known activity of 109 Cd to the International Reference System (SIR). The PTB result replaces their previous measurement of 1994 and the NIST result updates their 1986 CCRI(II) comparison result. The values of the activity submitted were about 15 MBq and 42 MBq. The new key comparison results have replaced the earlier values in the matrix of degrees of equivalence that now contains six results, identifier BIPM.RI(II)-K1.Cd-109, to which the remaining eleven results from the CCRI(II)-K2.Cd-109 held in 1986 are still linked. (authors)

  4. Preparation and LSC Standardization of ''89Sr (DNP) Using the CIEMAT/NIST Method; Preparacion del ''89Sr(DNP) y calibracion por centelleo liquido, mediante el metodo CIEMAT/NIST

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Barquero, L.; Los Arcos Merino, J. M.; Grau Malonda, A.

    1994-07-01

    A procedure for preparation of liquid scintillation counting samples of the strontium DNP complex, labelled with ''89Sr, is described, the chemical quench, the counting stability and spectral evolution of this compound is studied in six scintillators, Toluene, Toluene-alcohol, Dioxane-naphthalene, HiSafe II, Ultima- Gold and Instagel. The liquid scintillation standardization of 89Sr-DNP by the CIEMAT/NIST method, using HiSafe II and Ultima-Gold scintillators, has been carried out. The discrepancies between experimental and computed efficiencies are lower than 0.38% and 0.48%, respectively. The solution has been standardized in terms of activity concentration to an overall uncertainty of 0,38%. (Author) 10 refs.

  5. Smart Electronic Laboratory Notebooks for the NIST Research Environment.

    Science.gov (United States)

    Gates, Richard S; McLean, Mark J; Osborn, William A

    2015-01-01

    Laboratory notebooks have been a staple of scientific research for centuries for organizing and documenting ideas and experiments. Modern laboratories are increasingly reliant on electronic data collection and analysis, so it seems inevitable that the digital revolution should come to the ordinary laboratory notebook. The most important aspect of this transition is to make the shift as comfortable and intuitive as possible, so that the creative process that is the hallmark of scientific investigation and engineering achievement is maintained, and ideally enhanced. The smart electronic laboratory notebooks described in this paper represent a paradigm shift from the old pen and paper style notebooks and provide a host of powerful operational and documentation capabilities in an intuitive format that is available anywhere at any time.

  6. Gas Hydrate Research Database and Web Dissemination Channel

    Energy Technology Data Exchange (ETDEWEB)

    Micheal Frenkel; Kenneth Kroenlein; V Diky; R.D. Chirico; A. Kazakow; C.D. Muzny; M. Frenkel

    2009-09-30

    To facilitate advances in application of technologies pertaining to gas hydrates, a United States database containing experimentally-derived information about those materials was developed. The Clathrate Hydrate Physical Property Database (NIST Standard Reference Database {number_sign} 156) was developed by the TRC Group at NIST in Boulder, Colorado paralleling a highly-successful database of thermodynamic properties of molecular pure compounds and their mixtures and in association with an international effort on the part of CODATA to aid in international data sharing. Development and population of this database relied on the development of three components of information-processing infrastructure: (1) guided data capture (GDC) software designed to convert data and metadata into a well-organized, electronic format, (2) a relational data storage facility to accommodate all types of numerical and metadata within the scope of the project, and (3) a gas hydrate markup language (GHML) developed to standardize data communications between 'data producers' and 'data users'. Having developed the appropriate data storage and communication technologies, a web-based interface for both the new Clathrate Hydrate Physical Property Database, as well as Scientific Results from the Mallik 2002 Gas Hydrate Production Research Well Program was developed and deployed at http://gashydrates.nist.gov.

  7. Estimation of neutron mean wavelength from rocking curve dataThis work is a contribution of NIST, an agency of the US Government, and not subject to copyright laws.

    Science.gov (United States)

    Coakley, K. J.; Chowdhuri, Z.; Snow, W. M.; Richardson, J. M.; Dewey, M. S.

    2003-01-01

    At NIST, an in-beam neutron lifetime experiment is underway. In part of the experiment, a neutron detector is calibrated. The accuracy of the detector calibration depends, in part, on how accurately the mean wavelength of a neutron beam can be estimated from rocking curve data. Based on a stochastic model for neutron scattering, we simulate rocking curve data. To speed up the simulation, an importance sampling method is used. For the cases studied, importance sampling reduces the execution time of the simulation code by over a factor of 500. For simulated data, the statistical bias of the mean wavelength estimate is found to be 0.004%. This work is a contribution of NIST, an agency of the US Government, and not subject to copyright laws.

  8. High accuracy determination of trace elements in NIST standard reference materials by isotope dilution ICP-MS

    International Nuclear Information System (INIS)

    Paulsen, P.J.; Beary, E.S.

    1996-01-01

    At NIST (National Institute of Standards and Technology), ICP-MS ID (inductively coupled mass spectrometry isotope dilution) has been used to certify a wide range of elements in a variety of materials with high accuracy. Both the chemical preparation and instrumental procedures are simpler than with other ID mass spectrometric techniques. The ICP-MS has picogram/ml detection limits for most elements using fixed operating parameters. Chemical separations are required only to remove an interference (from molecular ions as well as isobaric atoms), or to pre-concentrate the analyte. For example, chemical separations were required for the analysis of SRM 2711, Montana II Soil, but not for boron in peach leaves, SRM 1547.(3 refs., 3 tabs., 2 figs

  9. Primary standardization of C-14 by means of CIEMAT/NIST, TDCR and 4πβ-γ methods

    International Nuclear Information System (INIS)

    Kuznetsova, Maria

    2016-01-01

    In this work, the primary standardization of "1"4C solution, which emits beta particles of maximum energy 156 keV, was made by means of three different methods: CIEMAT/NIST and TDCR (Triple To Double Coincidence Ratio) methods in liquid scintillation systems and the tracing method, in the 4πβ-γ coincidence system. TRICARB LSC (Liquid Scintillator Counting) system, equipped with two photomultipliers tubes, was used for CIEMAT/NIST method, using a "3H standard that emits beta particles with maximum energy of 18.7 keV, as efficiency tracing. HIDEX 300SL LSC system, equipped with three photomultipliers tubes, was used for TDCR method. Samples of "1"4C and "3H, for the liquid scintillator system, were prepared using three commercial scintillation cocktails, UltimaGold, Optiphase Hisafe3 and InstaGel-Plus, in order to compare the performance in the measurements. All samples were prepared with 15 mL scintillators, in glass vials with low potassium concentration. Known aliquots of radioactive solution were dropped onto the cocktail scintillators. In order to obtain the quenching parameter curve, a nitro methane carrier solution and 1 mL of distilled water were used. For measurements in the 4πβ-γ system, "6"0Co was used as beta gamma emitter. SCS (software coincidence system) was applied and the beta efficiency was changed by using electronic discrimination. The behavior of the extrapolation curve was predicted with code ESQUEMA, using Monte Carlo technique. The "1"4C activity obtained by the three methods applied in this work was compared and the results showed to be in agreement, within the experimental uncertainty. (author)

  10. Dielectric RheoSANS - Simultaneous Interrogation of Impedance, Rheology and Small Angle Neutron Scattering of Complex Fluids.

    Science.gov (United States)

    Richards, Jeffrey J; Gagnon, Cedric V L; Krzywon, Jeffery R; Wagner, Norman J; Butler, Paul D

    2017-04-10

    A procedure for the operation of a new dielectric RheoSANS instrument capable of simultaneous interrogation of the electrical, mechanical and microstructural properties of complex fluids is presented. The instrument consists of a Couette geometry contained within a modified forced convection oven mounted on a commercial rheometer. This instrument is available for use on the small angle neutron scattering (SANS) beamlines at the National Institute of Standards and Technology (NIST) Center for Neutron Research (NCNR). The Couette geometry is machined to be transparent to neutrons and provides for measurement of the electrical properties and microstructural properties of a sample confined between titanium cylinders while the sample undergoes arbitrary deformation. Synchronization of these measurements is enabled through the use of a customizable program that monitors and controls the execution of predetermined experimental protocols. Described here is a protocol to perform a flow sweep experiment where the shear rate is logarithmically stepped from a maximum value to a minimum value holding at each step for a specified period of time while frequency dependent dielectric measurements are made. Representative results are shown from a sample consisting of a gel composed of carbon black aggregates dispersed in propylene carbonate. As the gel undergoes steady shear, the carbon black network is mechanically deformed, which causes an initial decrease in conductivity associated with the breaking of bonds comprising the carbon black network. However, at higher shear rates, the conductivity recovers associated with the onset of shear thickening. Overall, these results demonstrate the utility of the simultaneous measurement of the rheo-electro-microstructural properties of these suspensions using the dielectric RheoSANS geometry.

  11. Optimization of 6LiF:ZnS(Ag) scintillator light yield using GEANT4

    Science.gov (United States)

    Yehuda-Zada, Y.; Pritchard, K.; Ziegler, J. B.; Cooksey, C.; Siebein, K.; Jackson, M.; Hurlbut, C.; Kadmon, Y.; Cohen, Y.; Ibberson, R. M.; Majkrzak, C. F.; Maliszewskyj, N. C.; Orion, I.; Osovizky, A.

    2018-06-01

    A new cold neutron detector has been developed at the NIST Center for Neutron Research (NCNR) for the CANDoR (Chromatic Analysis Neutron Diffractometer or Reflectometer) project. Geometric and performance constraints dictate that this detector be exceptionally thin (∼ 2 mm). For this reason, the design of the detector consists of a 6LiF:ZnS(Ag) scintillator with embedded wavelength shifting (WLS) fibers. We used the GEANT4 package to simulate neutron capture and light transport in the detector to optimize the composition and arrangement of materials to satisfy the competing requirements of high neutron capture probability and light production and transport. In the process, we have developed a method for predicting light collection and total neutron detection efficiency for different detector configurations. The simulation was performed by adjusting crucial parameters such as the scintillator stoichiometry, light yield, component grain size, WLS fiber geometry, and reflectors at the outside edges of the scintillator volume. Three different detector configurations were fabricated and their test results were correlated with the simulations. Through this correlation we have managed to find a common photon threshold for the different detector configurations which was then used to simulate and predict the efficiencies for many other detector configurations. New detectors that have been fabricated based on simulation results yielding the desired sensitivity of 90% for 3.27 meV (5 Å) cold neutrons. The simulation has proven to be a useful tool by dramatically reducing the development period and the required number of detector prototypes. It can be used to test new designs with different thicknesses and different target neutron energies.

  12. Repeatability of magnetic resonance fingerprinting T1 and T2 estimates assessed using the ISMRM/NIST MRI system phantom.

    Science.gov (United States)

    Jiang, Yun; Ma, Dan; Keenan, Kathryn E; Stupic, Karl F; Gulani, Vikas; Griswold, Mark A

    2017-10-01

    The purpose of this study was to evaluate accuracy and repeatability of T 1 and T 2 estimates of a MR fingerprinting (MRF) method using the ISMRM/NIST MRI system phantom. The ISMRM/NIST MRI system phantom contains multiple compartments with standardized T 1 , T 2 , and proton density values. Conventional inversion-recovery spin echo and spin echo methods were used to characterize the T 1 and T 2 values in the phantom. The phantom was scanned using the MRF-FISP method over 34 consecutive days. The mean T 1 and T 2 values were compared with the values from the spin echo methods. The repeatability was characterized as the coefficient of variation of the measurements over 34 days. T 1 and T 2 values from MRF-FISP over 34 days showed a strong linear correlation with the measurements from the spin echo methods (R 2  = 0.999 for T 1 ; R 2  = 0.996 for T 2 ). The MRF estimates over the wide ranges of T 1 and T 2 values have less than 5% variation, except for the shortest T 2 relaxation times where the method still maintains less than 8% variation. MRF measurements of T 1 and T 2 are highly repeatable over time and across wide ranges of T 1 and T 2 values. Magn Reson Med 78:1452-1457, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  13. The Atomic Spectroscopy Data Center at the National Institute of Standards and Technology (NIST). Activities 1999-2001

    International Nuclear Information System (INIS)

    Wiese, W.L.

    2001-01-01

    Dr. Wiese discussed activities and trends at the NIST Data Centers in the last two years. He reviewed priorities covered in data work and reviewed the bibliographic and numerical databases now on their website. The Atomic Spectra Database (ASD) is their main atomic physics web database and this is a reference data, e.g., the wavelength data is generally accurate to six significant figures and transition probability data is certain to with less than ±50%. Dr. Wiese also reported about recent work on the compilation and evaluation of data for wavelengths and energy levels of elements Cu, Kr and Mo (and several others), which are fusion relevant

  14. The Atomic Spectroscopy Data Center at the National Institute of Standards and Technology (NIST). Activities 1999-2001

    Energy Technology Data Exchange (ETDEWEB)

    Wiese, W L

    2001-12-01

    Dr. Wiese discussed activities and trends at the NIST Data Centers in the last two years. He reviewed priorities covered in data work and reviewed the bibliographic and numerical databases now on their website. The Atomic Spectra Database (ASD) is their main atomic physics web database and this is a reference data, e.g., the wavelength data is generally accurate to six significant figures and transition probability data is certain to with less than {+-}50%. Dr. Wiese also reported about recent work on the compilation and evaluation of data for wavelengths and energy levels of elements Cu, Kr and Mo (and several others), which are fusion relevant.

  15. Optical Passive Sensor Calibration for Satellite Remote Sensing and the Legacy of NOAA and NIST Cooperation.

    Science.gov (United States)

    Datla, Raju; Weinreb, Michael; Rice, Joseph; Johnson, B Carol; Shirley, Eric; Cao, Changyong

    2014-01-01

    This paper traces the cooperative efforts of scientists at the National Oceanic and Atmospheric Administration (NOAA) and the National Institute of Standards and Technology (NIST) to improve the calibration of operational satellite sensors for remote sensing of the Earth's land, atmosphere and oceans. It gives a chronological perspective of the NOAA satellite program and the interactions between the two agencies' scientists to address pre-launch calibration and issues of sensor performance on orbit. The drive to improve accuracy of measurements has had a new impetus in recent years because of the need for improved weather prediction and climate monitoring. The highlights of this cooperation and strategies to achieve SI-traceability and improve accuracy for optical satellite sensor data are summarized.

  16. IUPAC-NIST Solubility Data Series. 95. Alkaline Earth Carbonates in Aqueous Systems. Part 2. Ca

    Science.gov (United States)

    Vanderdeelen, Jan

    2012-06-01

    The alkaline earth carbonates are an important class of minerals. This article is part of a volume in the IUPAC-NIST Solubility Data Series that compiles and critically evaluates solubility data of the alkaline earth carbonates in water and in simple aqueous electrolyte solutions. Part 1 outlined the procedure adopted in this volume, and presented the beryllium and magnesium carbonates. Part 2, the current paper, compiles and critically evaluates the solubility data of calcium carbonate. The chemical forms included are the anhydrous CaCO3 types calcite, aragonite, and vaterite, the monohydrate monohydrocalcite (CaCO3. H2O), the hexahydrate ikaite (CaCO3.6H2O), and an amorphous form. The data were analyzed with two model variants, and thermodynamic data of each form consistent with each of the models and with the CODATA key values for thermodynamics are presented.

  17. IUPAC-NIST Solubility Data Series. 95. Alkaline Earth Carbonates in Aqueous Systems. Part 2. Ca

    International Nuclear Information System (INIS)

    De Visscher, Alex; Vanderdeelen, Jan

    2012-01-01

    The alkaline earth carbonates are an important class of minerals. This article is part of a volume in the IUPAC-NIST Solubility Data Series that compiles and critically evaluates solubility data of the alkaline earth carbonates in water and in simple aqueous electrolyte solutions. Part 1 outlined the procedure adopted in this volume, and presented the beryllium and magnesium carbonates. Part 2, the current paper, compiles and critically evaluates the solubility data of calcium carbonate. The chemical forms included are the anhydrous CaCO 3 types calcite, aragonite, and vaterite, the monohydrate monohydrocalcite (CaCO 3 · H 2 O), the hexahydrate ikaite (CaCO 3 ·6H 2 O), and an amorphous form. The data were analyzed with two model variants, and thermodynamic data of each form consistent with each of the models and with the CODATA key values for thermodynamics are presented.

  18. 76 FR 49436 - Submission for OMB Review; Comment Request

    Science.gov (United States)

    2011-08-10

    ... encourage them to inspire students to pursue careers in science, technology, engineering, and mathematics... Science Teachers (NIST Summer Institute) and the NIST Research Experience for Teachers (NIST RET) Applicant Requirements. OMB Control Number: 0693-0059. Form Number(s): NIST-1103. Type of Request: Regular...

  19. Evaluation of lead isotope compositions of NIST NBS 981 measured by thermal ionization mass spectrometer and multiple-collector inductively coupled plasma mass spectrometer

    Directory of Open Access Journals (Sweden)

    Honglin Yuan

    2016-09-01

    Full Text Available Because Pb isotopes can be used for tracing, they are widely used in many disciplines. The detection and analysis of Pb isotopes of bulk samples are usually conducted using thermal ionization mass spectrometer (TIMS and multiple-collector inductively coupled plasma mass spectrometer (MC-ICP-MS, both of which need external reference materials with known isotopic compositions to correct for the mass discrimination effect produced during analysis. NIST NBS 981 is the most widely used reference material for Pb isotope analysis; however, the isotopic compositions reported by various analytical laboratories, especially those using TIMS, vary from each other. In this study, we statistically evaluated 229 reported TIMS analysis values collected by GeoReM in the last 30 years, 176 reported MC-ICP-MS analysis values, and 938 MC-ICP-MS analysis results from our laboratory in the last five years. After careful investigation, only 40 TIMS results were found to have double or triple spikes. The ratios of the overall weighted averages, 206Pb/204Pb, 207Pb/204Pb, and 208Pb/204Pb, obtained from 40 spiked TIMS reports and 1114 MC-ICP-MS results of NIST NBS 981 isotopes were 16.9406 ± 0.0003 (2s, 15.4957 ± 0.0002 (2s, and 36.7184 ± 0.0007 (2s, respectively.

  20. IUPAC-NIST Solubility Data Series. 95. Alkaline Earth Carbonates in Aqueous Systems. Part 2. Ca

    Energy Technology Data Exchange (ETDEWEB)

    De Visscher, Alex; Vanderdeelen, Jan [Department of Chemical and Petroleum Engineering, and Centre for Environmental Engineering Research and Education (CEERE), Schulich School of Engineering, University of Calgary, Calgary, Alberta, T2N 1N4 (Canada); Department of Applied Analytical and Physical Chemistry, Faculty of Bioscience Engineering, Ghent University, B-9000 Ghent (Belgium)

    2012-06-15

    The alkaline earth carbonates are an important class of minerals. This article is part of a volume in the IUPAC-NIST Solubility Data Series that compiles and critically evaluates solubility data of the alkaline earth carbonates in water and in simple aqueous electrolyte solutions. Part 1 outlined the procedure adopted in this volume, and presented the beryllium and magnesium carbonates. Part 2, the current paper, compiles and critically evaluates the solubility data of calcium carbonate. The chemical forms included are the anhydrous CaCO{sub 3} types calcite, aragonite, and vaterite, the monohydrate monohydrocalcite (CaCO{sub 3}{center_dot} H{sub 2}O), the hexahydrate ikaite (CaCO{sub 3}{center_dot}6H{sub 2}O), and an amorphous form. The data were analyzed with two model variants, and thermodynamic data of each form consistent with each of the models and with the CODATA key values for thermodynamics are presented.

  1. Analysis of JPSS J1 VIIRS Polarization Sensitivity Using the NIST T-SIRCUS

    Science.gov (United States)

    McIntire, Jeffrey W.; Young, James B.; Moyer, David; Waluschka, Eugene; Oudrari, Hassan; Xiong, Xiaoxiong

    2015-01-01

    The polarization sensitivity of the Joint Polar Satellite System (JPSS) J1 Visible Infrared Imaging Radiometer Suite (VIIRS) measured pre-launch using a broadband source was observed to be larger than expected for many reflective bands. Ray trace modeling predicted that the observed polarization sensitivity was the result of larger diattenuation at the edges of the focal plane filter spectral bandpass. Additional ground measurements were performed using a monochromatic source (the NIST T-SIRCUS) to input linearly polarized light at a number of wavelengths across the bandpass of two VIIRS spectral bands and two scan angles. This work describes the data processing, analysis, and results derived from the T-SIRCUS measurements, comparing them with broadband measurements. Results have shown that the observed degree of linear polarization, when weighted by the sensor's spectral response function, is generally larger on the edges and smaller in the center of the spectral bandpass, as predicted. However, phase angle changes in the center of the bandpass differ between model and measurement. Integration of the monochromatic polarization sensitivity over wavelength produced results consistent with the broadband source measurements, for all cases considered.

  2. Measured Polarized Spectral Responsivity of JPSS J1 VIIRS Using the NIST T-SIRCUS

    Science.gov (United States)

    McIntire, Jeff; Young, James B.; Moyer, David; Waluschka, Eugene; Xiong, Xiaoxiong

    2015-01-01

    Recent pre-launch measurements performed on the Joint Polar Satellite System (JPSS) J1 Visible Infrared Imaging Radiometer Suite (VIIRS) using the National Institute of Standards and Technology (NIST) Traveling Spectral Irradiance and Radiance Responsivity Calibrations Using Uniform Sources (T-SIRCUS) monochromatic source have provided wavelength dependent polarization sensitivity for select spectral bands and viewing conditions. Measurements were made at a number of input linear polarization states (twelve in total) and initially at thirteen wavelengths across the bandpass (later expanded to seventeen for some cases). Using the source radiance information collected by an external monitor, a spectral responsivity function was constructed for each input linear polarization state. Additionally, an unpolarized spectral responsivity function was derived from these polarized measurements. An investigation of how the centroid, bandwidth, and detector responsivity vary with polarization state was weighted by two model input spectra to simulate both ground measurements as well as expected on-orbit conditions. These measurements will enhance our understanding of VIIRS polarization sensitivity, improve the design for future flight models, and provide valuable data to enhance product quality in the post-launch phase.

  3. Linac design study for an intense neutron-source driver

    International Nuclear Information System (INIS)

    Lynch, M.T.; Browman, A.; DeHaven, R.; Jameson, R.; Jason, A.; Neuschaefer, G.; Tallerico, P.; Regan, A.

    1993-01-01

    The 1-MW spallation-neutron source under design study at Los Alamos is driven by a linac-compressor-ring scheme that utilizes a large portion of the existing Los Alamos Meson Physics Facility (LAMPF) linac, as well as the facility infrastructure. The project is referred to as the National Center for Neutron Research (NCNR). A second phase of the proposal will upgrade the driver power to 5 MW. A description of the 1-MW scheme is given in this paper. In addition, the upgrade path to the substantial increase of beam power required for the 5 MW scenario is discussed

  4. Standards and measurements for assessing bone health-workshop report co-sponsored by the International Society for Clinical Densitometry (ISCD) and the National Institute of Standards and Technology (NIST).

    Science.gov (United States)

    Bennett, Herbert S; Dienstfrey, Andrew; Hudson, Lawrence T; Oreskovic, Tammy; Fuerst, Thomas; Shepherd, John

    2006-01-01

    This article reports and discusses the results of the recent ISCD-NIST Workshop on Standards and Measurements for Assessing Bone Health. The purpose of the workshop was to assess the status of efforts to standardize and compare results from dual-energy X-ray absorptiometry (DXA) scans, and then to identify and prioritize ongoing measurement and standards needs.

  5. Librarians and Scientists Partner to Address Data Management: Taking Collaboration to the Next Level.

    Science.gov (United States)

    Medina-Smith, Andrea; Tryka, Kimberly A; Silcox, Barbara P; Hanisch, Robert J

    2016-01-01

    This study looks at the changing way in which the Information Services Office (ISO) at the National Institute of Standards and Technology (NIST) provides services to NIST scientific and technical staff throughout their research and publishing cycles. These services include the more traditional services of a research library as well as publishing NIST technical reports and The Journal of Research of NIST , and preserving and exhibiting scientific instruments and other artifacts. ISO has always prided itself on having a close relationship with its customers, providing a high level of service, and developing new services to stay in front of NIST researcher needs. Through a concerted, strategic effort since the late 1990s, ISO has developed and promoted relationships with its key customers through its Lab Liaison Program. This paper discusses the relationship ISO has developed with the Office of Data and Informatics (ODI), how this relationship was forged, and how this collaboration will serve as a model for working with the other labs and programs at NIST. It will also discuss the risks and opportunities of this new collaborative service model, how ISO positioned itself to become an equal partner with ODI in the exploration of solutions to data management issues, and the benefits of the relationship from ODI's perspective. A pattern of strategic changes to the services and activities offered by the Lab Liaison program has put ISO in the position to collaborate as peers with researchers at NIST. This study provides an overview of how ISO made strategic decisions to incorporate non-traditional services to support data management at NIST.

  6. 76 FR 93 - Summer Undergraduate Research Fellowships (SURF) NIST Gaithersburg and Boulder Programs...

    Science.gov (United States)

    2011-01-03

    ... encourage outstanding undergraduate students to pursue careers in science and engineering. The objective of...: Catalog of Federal Domestic Assistance Name and Number: Measurement and Engineering Research and Standards... engineering sciences and, as the lead Federal agency for technology transfer, it provides a strong interface...

  7. JY1 time scale: a new Kalman-filter time scale designed at NIST

    International Nuclear Information System (INIS)

    Yao, Jian; Parker, Thomas E; Levine, Judah

    2017-01-01

    We report on a new Kalman-filter hydrogen-maser time scale (i.e. JY1 time scale) designed at the National Institute of Standards and Technology (NIST). The JY1 time scale is composed of a few hydrogen masers and a commercial Cs clock. The Cs clock is used as a reference clock to ease operations with existing data. Unlike other time scales, the JY1 time scale uses three basic time-scale equations, instead of only one equation. Also, this time scale can detect a clock error (i.e. time error, frequency error, or frequency drift error) automatically. These features make the JY1 time scale stiff and less likely to be affected by an abnormal clock. Tests show that the JY1 time scale deviates from the UTC by less than  ±5 ns for ∼100 d, when the time scale is initially aligned to the UTC and then is completely free running. Once the time scale is steered to a Cs fountain, it can maintain the time with little error even if the Cs fountain stops working for tens of days. This can be helpful when we do not have a continuously operated fountain or when the continuously operated fountain accidentally stops, or when optical clocks run occasionally. (paper)

  8. IGORR 2: Proceedings of the 2. meeting of the International Group On Research Reactors

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1992-07-01

    The International group on Research Reactors was formed to facilitate the sharing of knowledge and experience among those institutions and individuals who are actively working to design, build, and promote new research reactors or to make significant upgrades to existing facilities. Sessions during this second meeting were devoted to research reactor reports (GRENOBLE reactor, FRM-II, HIFAR, PIK, reactors at JAERI, MAPLE, ANS, NIST, MURR, TRIGA, BR-2, SIRIUS 2); other neutron sources; and two workshops were dealing with research and development results and needs and reports on progress in needed of R and D areas identified at IGORR 1.

  9. IGORR 2: Proceedings of the 2. meeting of the International Group On Research Reactors

    International Nuclear Information System (INIS)

    1992-01-01

    The International group on Research Reactors was formed to facilitate the sharing of knowledge and experience among those institutions and individuals who are actively working to design, build, and promote new research reactors or to make significant upgrades to existing facilities. Sessions during this second meeting were devoted to research reactor reports (GRENOBLE reactor, FRM-II, HIFAR, PIK, reactors at JAERI, MAPLE, ANS, NIST, MURR, TRIGA, BR-2, SIRIUS 2); other neutron sources; and two workshops were dealing with research and development results and needs and reports on progress in needed of R and D areas identified at IGORR 1

  10. Neutron capture prompt gamma-ray activation analysis at the NIST cold neutron research facility

    Energy Technology Data Exchange (ETDEWEB)

    Lindstrom, R M; Zeisler, R; Vincent, D H; Greenberg, R R; Stone, C A; Mackey, E A [National Inst. of Standards and Technology, Gaithersburg, MD (United States); Anderson, D L [Food and Drug Administration, Washington, DC (United States); Clark, D D [Cornell Univ., Ithaca, NY (United States)

    1993-01-01

    An instrument for neutron capture prompt gamma-ray activation analysis (PGAA) has been constructed as part of the Cold Neutron Research Facility at the 20 MW National Institute of Standards and Technology Research Reactor. The neutron fluence rate (thermal equivalent) is 1.5*10[sup 8] n*cm[sup -2]*s[sup -] [sup 1], with negligible fast neutrons and gamma-rays. With compact geometry and hydrogen-free construction, the sensitivity is sevenfold better than an existing thermal instrument. Hydrogen background is thirtyfold lower. (author) 17 refs.; 2 figs.

  11. A reload and startup plan for conversion of the NIST research reactor

    Energy Technology Data Exchange (ETDEWEB)

    Diamond, D. J. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-03-31

    The National Institute of Standards and Technology operates a 20 MW research reactor for neutron-based research. The heavy-water moderated and cooled reactor is fueled with high-enriched uranium (HEU) but a program to convert the reactor to low-enriched uranium (LEU) fuel is underway. Among other requirements, a reload and startup test plan must be submitted to the U.S. Nuclear Regulatory Commission (NRC) for their approval. The NRC provides guidance for what should be in the plan to ensure that the licensee has sufficient information to operate the reactor safely. Hence, a plan has been generated consisting of two parts. The reload portion of the plan specifies the fuel management whereby initially only two LEU fuel elements are in the core for eight fuel cycles. This is repeated until a point when the optimum approach is to place four fresh LEU elements into the reactor each cycle. This final transition is repeated and after eight cycles the reactor is completely fueled with LEU. By only adding two LEU fuel elements initially, the plan allows for the consumption of HEU fuel elements that are expected to be in storage at the time of conversion and provides additional qualification of production LEU fuel under actual operating conditions. Because the reload is to take place over many fuel cycles, startup tests will be done at different stages of the conversion. The tests, to be compared with calculations to show that the reactor will operate as planned, are the measurement of critical shim arm position and shim arm and regulating rod reactivity worths. An acceptance criterion for each test is specified based on technical specifications that relate to safe operation. Additional tests are being considered that have less safety significance but may be of interest to bolster the validation of analysis tools.

  12. Transferability of ASTM/NIST alanine-polyethylene recipe at ISS. American Society for Testing and Materials/National Institute for Standards and Technology. Istituto Superiore de Sanita

    Science.gov (United States)

    De Angelis C; Fattibene; Onori; Petetti; Bartolotta; Sansone Santamaria A

    2000-05-01

    Alanine-polyethylene solid state dosimeters were prepared at Istituto Superiore di Sanita (ISS) following the recipe proposed by National Institute of Standards and Technology (NIST) with the goal of testing its transferability. Dosimeters were prepared using 95% alanine and 5% polyethylene, by weight. They are rugged and of increased sensitivity, repeatability and reproducibility as respect to the ISS alanine-paraffin pellets. Reproducibility of about 1% was obtained at 10 Gy and at 3 Gy if one single pellet or a stack of five dosimeters were used, respectively.

  13. 75 FR 55306 - Smart Grid Advisory Committee

    Science.gov (United States)

    2010-09-10

    ... accommodate Committee business. The final agenda will be posted on the Smart Grid Web site at http://www.nist.... The Committee shall provide input to NIST on the Smart Grid Standards, Priority, and Gaps. The... research and standards activities. 5. Upon request of the Director of NIST, the Committee will prepare...

  14. Chemical engineering: Measurements for a competitive age

    Science.gov (United States)

    1986-01-01

    The NIST (National Institute of Standards and Technology) activities supporting chemical research, environmental research, combustion and fuel research, and related industries are described in this video. Highlights include private sector involvement in the research and associated and guest scientist programs, the calibration of customers' instruments, and the direct funding for the NIST research projects by outside industries.

  15. 75 FR 28785 - Visiting Committee on Advanced Technology

    Science.gov (United States)

    2010-05-24

    ... business, research, new product development, engineering, labor, education, management consulting... include an update on NIST; presentations on NIST progress in documentary standards for Smart Grid...

  16. Biomass-burning derived aromatic acids in NIST standard reference material 1649b and the environmental implications

    Science.gov (United States)

    Gao, Shaopeng; Xu, Baiqing; Dong, Xueling; Zheng, Xiaoyan; Wan, Xin; Kang, Shichang; Song, Qiuyin; Kawamura, Kimitaka; Cong, Zhiyuan

    2018-07-01

    Biomass burning is a serious problem in the environment and climate system. However, the source identification of biomass-burning aerosols was somewhat impeded, partly due to the difficulty in quantification of relevant molecular markers. In this study, we present reference values for five aromatic acids (including p-hydroxybenzoic, vanillic, dehydroabietic, syringic and p-coumaric acids) in the NIST Standard Reference Material (SRM) 1649b. The concentration of levoglucosan was also revisited. Notable positive matrix effect was found for vanillic, dehydroabietic, syringic and coumaric acid. Using the standard addition method, the average value of p-hydroxybenzoic, vanillic, syringic, dehydroabietic and p-coumaric acids in SRM 1649b were found to be 26.9, 9.53, 1.13, 7.60 and 1.66 μg g-1, respectively. The analytical method developed in this study was also applied to the PM10 samples from Beijing and PM2.5 samples from South Asia (Godavari, Nepal). The ratios of vanillic to p-hydroxybenzoic acid and syringic to vanillic acid further suggested that their biomass-burning types are mainly related to hard wood and herbaceous species (i.e., agricultural residues).

  17. Application of the k{sub 0}-INAA method for analysis of biological samples at the pneumatic station of the IEA-R1 nuclear research reactor

    Energy Technology Data Exchange (ETDEWEB)

    Puerta, Daniel C.; Figueiredo, Ana Maria G.; Semmler, Renato, E-mail: dcpuerta@hotmail.com, E-mail: anamaria@ipen.br, E-mail: rsemmler@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Jacimovic, Radojko, E-mail: radojko.jacimovic@ijs.si [Jozef Stefan Institute (JSI), Ljubljana, LJU (Slovenia). Department of Environmental Sciences

    2013-07-01

    As part of the process of implementation of the k{sub 0}-INAA standardization method at the Neutron Activation Laboratory (LAN-IPEN), Sao Paulo, Brazil, this study presents the results obtained for the analysis of short and medium-lived nuclides in biological samples by k{sub 0}-INAA using the program k{sub 0}-IAEA, provided by the International Atomic Energy Agency (IAEA). The elements Al, Ba, Br, Na, K, Mn, Mg, Sr and V were determined with respect to gold ({sup 197}Au) using the pneumatic station facility of the IEA-R1 4.5 MW swimming pool nuclear research reactor, Sao Paulo. Characterization of the pneumatic station was carried out by using the 'bare triple-monitor' method with {sup 197}Au-{sup 96}Zr-{sup 94}Zr. The Certified Reference Material IRMM-530R Al-0.1%Au alloy and high purity zirconium comparators were used. The efficiency curves of the gamma-ray spectrometer used were determined by measuring calibrated radioactive sources at the usually utilized counting geometries. The method was validated by analyzing the reference materials NIST SRM 1547 Peach Leaves, INCT-MPH-2 Mixed Polish Herbs and NIST SRM 1573a Tomato Leaves. The concentration results obtained agreed with certified, reference and recommended values, showing relative errors (bias, %) less than 30% for most elements. The Coefficients of Variation were below 20%, showing a good reproducibility of the results. The E{sub n}-number showed that all results, except Na in NIST SRM 1547 and NIST SRM 1573a and Al in INCT-MPH-2, were within 95% confidence interval. (author)

  18. Mercury CEM Calibration

    Energy Technology Data Exchange (ETDEWEB)

    John F. Schabron; Joseph F. Rovani; Susan S. Sorini

    2007-03-31

    The Clean Air Mercury Rule (CAMR) which was published in the Federal Register on May 18, 2005, requires that calibration of mercury continuous emissions monitors (CEMs) be performed with NIST-traceable standards. Western Research Institute (WRI) is working closely with the Electric Power Research Institute (EPRI), the National Institute of Standards and Technology (NIST), and the Environmental Protection Agency (EPA) to facilitate the development of the experimental criteria for a NIST traceability protocol for dynamic elemental mercury vapor generators. The traceability protocol will be written by EPA. Traceability will be based on the actual analysis of the output of each calibration unit at several concentration levels ranging from about 2-40 ug/m{sup 3}, and this analysis will be directly traceable to analyses by NIST using isotope dilution inductively coupled plasma/mass spectrometry (ID ICP/MS) through a chain of analyses linking the calibration unit in the power plant to the NIST ID ICP/MS. Prior to this project, NIST did not provide a recommended mercury vapor pressure equation or list mercury vapor pressure in its vapor pressure database. The NIST Physical and Chemical Properties Division in Boulder, Colorado was subcontracted under this project to study the issue in detail and to recommend a mercury vapor pressure equation that the vendors of mercury vapor pressure calibration units can use to calculate the elemental mercury vapor concentration in an equilibrium chamber at a particular temperature. As part of this study, a preliminary evaluation of calibration units from five vendors was made. The work was performed by NIST in Gaithersburg, MD and Joe Rovani from WRI who traveled to NIST as a Visiting Scientist.

  19. Structural fire resistance experimental research priority needs of U.S. industry

    CERN Document Server

    Almand, Kathleen H

    2012-01-01

    Structural Fire Resistance Experimental Research – Priority Needs of U.S. Industry provides a synthesis of stakeholder input to a prioritized agenda for research at the National Fire Research Laboratory (NFRL) at the National Institute of Standards and Technology (NIST) designed to accelerate the implementation of performance-based fire engineering for structures. The NFRL presents a broad range of unanswered questions regarding the performance of real structures in fire conditions, and informs performance-based design methods and standards in this field. The authors conducted a comprehensive literature review of large-scale structural fire testing and compiled research needs from a variety of sources. The book addresses major issues of broad concern in the fire community, such as real fire exposure and structural response, composite floor system performance, enhancing modeling performance, and understanding the embedded safety features in design methods. It concludes with a prioritized set of research reco...

  20. VASIR: An Open-Source Research Platform for Advanced Iris Recognition Technologies.

    Science.gov (United States)

    Lee, Yooyoung; Micheals, Ross J; Filliben, James J; Phillips, P Jonathon

    2013-01-01

    The performance of iris recognition systems is frequently affected by input image quality, which in turn is vulnerable to less-than-optimal conditions due to illuminations, environments, and subject characteristics (e.g., distance, movement, face/body visibility, blinking, etc.). VASIR (Video-based Automatic System for Iris Recognition) is a state-of-the-art NIST-developed iris recognition software platform designed to systematically address these vulnerabilities. We developed VASIR as a research tool that will not only provide a reference (to assess the relative performance of alternative algorithms) for the biometrics community, but will also advance (via this new emerging iris recognition paradigm) NIST's measurement mission. VASIR is designed to accommodate both ideal (e.g., classical still images) and less-than-ideal images (e.g., face-visible videos). VASIR has three primary modules: 1) Image Acquisition 2) Video Processing, and 3) Iris Recognition. Each module consists of several sub-components that have been optimized by use of rigorous orthogonal experiment design and analysis techniques. We evaluated VASIR performance using the MBGC (Multiple Biometric Grand Challenge) NIR (Near-Infrared) face-visible video dataset and the ICE (Iris Challenge Evaluation) 2005 still-based dataset. The results showed that even though VASIR was primarily developed and optimized for the less-constrained video case, it still achieved high verification rates for the traditional still-image case. For this reason, VASIR may be used as an effective baseline for the biometrics community to evaluate their algorithm performance, and thus serves as a valuable research platform.

  1. A Reload and Startup Plan for and #8233;Conversion of the NIST Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Diamond, D. J. [Brookhaven National Lab. (BNL), Upton, NY (United States); Varuttamaseni, A. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2017-09-30

    The National Institute of Standards and Technology operates a 20 MW research reactor for neutron-based research. The heavy-water moderated and cooled reactor is fueled with high-enriched uranium (HEU) but a program to convert the reactor to low-enriched uranium (LEU) fuel is underway. Among other requirements, a reload and startup test plan must be submitted to the U.S. Nuclear Regulatory Commission (NRC) for their approval. The NRC provides guidance for what should be in the plan to ensure that the licensee has sufficient information to operate the reactor safely. Hence, a plan has been generated consisting of two parts.The reload portion of the plan specifies the fuel management whereby initially only two LEU fuel elements are in the core for eight fuel cycles. This is repeated until a point when the optimum approach is to place four fresh LEU elements into the reactor each cycle. This final transition is repeated and after eight cycles the reactor is completely fueled with LEU. By only adding two LEU fuel elements initially, the plan allows for the consumption of HEU fuel elements that are expected to be in storage at the time of conversion and provides additional qualification of production LEU fuel under actual operating conditions. Because the reload is to take place over many fuel cycles, startup tests will be done at different stages of the conversion. The tests, to be compared with calculations to show that the reactor will operate as planned, are the measurement of critical shim arm position and shim arm and regulating rod reactivity worths. An acceptance criterion for each test is specified based on technical specifications that relate to safe operation. Additional tests are being considered that have less safety significance but may be of interest to bolster the validation of analysis tools.

  2. DANAIM's state-of-the-art encryption research

    DEFF Research Database (Denmark)

    Boyar, Joan

    2009-01-01

    The University of Southern Denmark together with NIST (National Institute of Standards and Technology - a non-regulatory federal agency with the US Department of Commerce) have jointly created a new invention available for advancing encryption standard S-Box applications....

  3. Quality control and performance evaluation of k0-based neutron activation analysis at the Portuguese research reactor

    International Nuclear Information System (INIS)

    Dung, H.M.; Freitas, M.C.; Blaauw, M.; Almeida, S.M.; Dionisio, I.; Canha, N.H.

    2010-01-01

    The quality control (QC) and performance evaluation for the k 0 -based neutron activation analysis (k 0 -NAA) at the Portuguese research reactor (RPI) has been developed with the intention of using the method to meet the demands of trace element analysis for the applications in environmental, epidemiological and nutritional studies amongst others. The QC and performance evaluation include the following aspects: (1) estimation of the overall/combined standard uncertainty from the primary uncertainty sources; (2) validation of the method using a synthetic multi-element standard (SMELS); and (3) analysis of the certified reference materials from the National Institute of Standards and Technology (USA): NIST-SRM-1633a and NIST-SRM-1648 and the reference material from the International Atomic Energy Agency: IAEA-RM-336, for the purpose of controlling the overall accuracy and precision of the analytical results. The obtained results revealed that the k 0 -NAA method established at the RPI was fit for the purpose. The overall/combined standard uncertainty was estimated for elements of interest in the intended applications. The laboratory's analytical results as compared to the assigned values with the bias were less than 12% for most elements, except for a few elements which biased within 13-18%. The u-score values for most elements were less than |1.64|, except for Co, La and Ti within |1.64|-|1.96| and Sc, Cr, K and Sb within |1.96|-|2.58|. The NIST-1633a was also analyzed over 14 months for the purpose of evaluating the reproducibility of the method. The quality factors of k 0 -NAA established at RPI were evaluated, proving that the method meets the requirements of trace element analysis, which is also considering the method's performance for which the k 0 -NAA affords a specific, rapid and convenient capability for the intended applications.

  4. Manajemen Risiko Keamanan Informasi Menggunakan Framework NIST SP 800-30 Revisi 1 (Studi Kasus: STMIK Sumedang

    Directory of Open Access Journals (Sweden)

    Fathoni Mahardika

    2017-07-01

    Full Text Available STMIK Sumedang merupakan institusi yang sudah terbiasa menggunakan perangkat teknologi, dimana pengawasannya dilakukan oleh suatu divisi tersendiri yaitu bagian UPT LPSI. Namun terdapat permasalahan dalam penggunaan TI yang ada saat ini antara lain : (1 Masih sering terjadinya insiden keamanan informasi yang menyebabkan terganggunya proses bisnis perusahaan, (2 Belum adanya pengawasan dan perencanaan yang tepat dalam pengelolaan keamanan informasi di STMIK Sumedang.Manajemen resiko adalah metode untuk penilaian dan mitigasi resiko terhadap aspek kebutuhan keamanan informasi yang memuat 3 unsur penting yaitu : Confidentiality (kerahasiaan, Integrity (integritas, dan Availability (ketersediaan. Manajemen resiko keamanan informasi yang digunakan mengacu pada NIST SP 800-30 Revisi 1. Standar ini digunakan sebagai acuan dalam melakukan manajemen resiko keamanan informasi, untuk mengantisipasi risiko agar kerugian tidak terjadi terhadap organisasi. Sehingga resiko dapat dikelola ke level yang dapat diterima organisasi. Diharapkan akan mengurangi dampak insiden sistem dan teknologi informasi di institusi perguruan tinggi, melindungi proses bisnis organisasi yang penting dari ancaman keamanan, meminimalisir risiko kerugian serta menghindari kegagalan serius terhadap informasi yang ada di STMIK Sumedang. Setelah dilakukan manajemen risiko maka diperlukan control keamanan sebagai dasar acuan bahwa risiko dilakukan mitigasi, diterima/ditransfer oleh pihak manajemen. Kontrol keamanan dikembangkan dari ISO 27002. Untuk mengetahui sejauh mana keamanan informasi organisasi maka dilakukan maturity keamanan informasi organisasi menggunakan control yang dikembangkan dari ISO 27002. Dari hasil maturity ini menjadi dasar dibuatnya rekomendasi standar kebijakan keamanan informasi di STMIK Sumedang.

  5. Status Report on the First Round of the Development of the Advanced Encryption Standard

    Science.gov (United States)

    Nechvatal, James; Barker, Elaine; Dodson, Donna; Dworkin, Morris; Foti, James; Roback, Edward

    1999-01-01

    In 1997, the National Institute of Standards and Technology (NIST) initiated a process to select a symmetric-key encryption algorithm to be used to protect sensitive (unclassified) Federal information in furtherance of NIST’s statutory responsibilities. In 1998, NIST announced the acceptance of 15 candidate algorithms and requested the assistance of the cryptographic research community in analyzing the candidates. This analysis included an initial examination of the security and efficiency characteristics for each algorithm. NIST has reviewed the results of this research and selected five algorithms (MARS, RC6™, Rijndael, Serpent and Twofish) as finalists. The research results and rationale for the selection of the finalists are documented in this report. The five finalists will be the subject of further study before the selection of one or more of these algorithms for inclusion in the Advanced Encryption Standard.

  6. Tailoring NIST Security Controls for the Ground System: Selection and Implementation -- Recommendations for Information System Owners

    Science.gov (United States)

    Takamura, Eduardo; Mangum, Kevin

    2016-01-01

    . Certain protective measures for the general enterprise may not be as efficient within the ground segment. This is what the authors have concluded through observations and analysis of patterns identified from the various security assessments performed on NASA missions such as MAVEN, OSIRIS-REx, New Horizons and TESS, to name a few. The security audits confirmed that the framework for managing information system security developed by the National Institute of Standards and Technology (NIST) for the federal government, and adopted by NASA, is indeed effective. However, the selection of the technical, operational and management security controls offered by the NIST model - and how they are implemented - does not always fit the nature and the environment where the ground system operates in even though there is no apparent impact on mission success. The authors observed that unfit controls, that is, controls that are not necessarily applicable or sufficiently effective in protecting the mission systems, are often selected to facilitate compliance with security requirements and organizational expectations even if the selected controls offer minimum or non-existent protection. This paper identifies some of the standard security controls that can in fact protect the ground system, and which of them offer little or no benefit at all. It offers multiple scenarios from real security audits in which the controls are not effective without, of course, disclosing any sensitive information about the missions assessed. In addition to selection and implementation of controls, the paper also discusses potential impact of recent legislation such as the Federal Information Security Modernization Act (FISMA) of 2014 - aimed at the enterprise - on the ground system, and offers other recommendations to Information System Owners (ISOs).

  7. Glycan characterization of the NIST RM monoclonal antibody using a total analytical solution: From sample preparation to data analysis.

    Science.gov (United States)

    Hilliard, Mark; Alley, William R; McManus, Ciara A; Yu, Ying Qing; Hallinan, Sinead; Gebler, John; Rudd, Pauline M

    Glycosylation is an important attribute of biopharmaceutical products to monitor from development through production. However, glycosylation analysis has traditionally been a time-consuming process with long sample preparation protocols and manual interpretation of the data. To address the challenges associated with glycan analysis, we developed a streamlined analytical solution that covers the entire process from sample preparation to data analysis. In this communication, we describe the complete analytical solution that begins with a simplified and fast N-linked glycan sample preparation protocol that can be completed in less than 1 hr. The sample preparation includes labelling with RapiFluor-MS tag to improve both fluorescence (FLR) and mass spectral (MS) sensitivities. Following HILIC-UPLC/FLR/MS analyses, the data are processed and a library search based on glucose units has been included to expedite the task of structural assignment. We then applied this total analytical solution to characterize the glycosylation of the NIST Reference Material mAb 8761. For this glycoprotein, we confidently identified 35 N-linked glycans and all three major classes, high mannose, complex, and hybrid, were present. The majority of the glycans were neutral and fucosylated; glycans featuring N-glycolylneuraminic acid and those with two galactoses connected via an α1,3-linkage were also identified.

  8. BILATERAL KEY COMPARISON SIM.T-K6.1 ON HUMIDITY STANDARDS IN THE DEW/FROST-POINT TEMPERATURE RANGE FROM −25 °C TO +20 °C

    Science.gov (United States)

    Meyer, C.W.; Hill, K.D.

    2015-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the National Research Council (NRC, Canada) between December 2014 and April, 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and NRC and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and NRC. PMID:26663952

  9. Recent advancements of wide-angle polarization analysis with 3He neutron spin filters

    International Nuclear Information System (INIS)

    Chen, W.C.; Gentile, T.R.; Ye, Q.; Kirchhoff, A.; Watson, S.M.; Rodriguez-Rivera, J.A.; Qiu, Y.; Broholm, C.

    2016-01-01

    Wide-angle polarization analysis with polarized 3 He based neutron spin filters (NSFs) has recently been employed on the Multi-Axis Crystal Spectrometer (MACS) at the National Institute of Standards and Technology Center for Neutron Research (NCNR). Over the past several years, the apparatus has undergone many upgrades to address the fundamental requirements for wide angle polarization analysis using spin exchange optical pumping based 3 He NSFs. In this paper, we report substantial improvements in the on-beam-line performance of the apparatus and progress toward routine user capability. We discuss new standard samples used for 3 He NSF characterization and the flipping ratio measurement on MACS. We further discuss the management of stray magnetic fields produced by operation of superconducting magnets on the MACS instrument, which can significantly reduce the 3 He polarization relaxation time. Finally, we present the results of recent development of horseshoe-shaped wide angle cells. (paper)

  10. NaKnowBaseTM: The EPA Nanomaterials Research ...

    Science.gov (United States)

    The ability to predict the environmental and health implications of engineered nanomaterials is an important research priority due to the exponential rate at which nanotechnology is being incorporated into consumer, industrial and biomedical applications. To address this need and develop predictive capability, we have created the NaKnowbaseTM, which provides a platform for the curation and dissemination of EPA nanomaterials data to support functional assay development, hazard risk models and informatic analyses. To date, we have combined relevant physicochemical parameters from other organizations (e.g., OECD, NIST), with those requested for nanomaterial data submitted to EPA under the Toxic Substances Control Act (TSCA). Physiochemical characterization data were collated from >400 unique nanomaterials including metals, metal oxides, carbon-based and hybrid materials evaluated or synthesized by EPA researchers. We constructed parameter requirements and table structures for encoding research metadata, including experimental factors and measured response variables. As a proof of concept, we illustrate how SQL-based queries facilitate a range of interrogations including, for example, relationships between nanoparticle characteristics and environmental or toxicological endpoints. The views expressed in this poster are those of the authors and may not reflect U.S. EPA policy. The purpose of this submission for clearance is an abstract for submission to a scientific

  11. Neutron beam applications - Polymer study and sample environment development for HANARO SANS instrument

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hong Doo [Kyunghee University, Seoul (Korea); Char, Kook Heon [Seoul National University, Seoul (Korea)

    2000-04-01

    A new SANS instrument will be installed in HANARO reactor near future and in parallel it is necessary to develop the sample environment facilities. One of the basic items is the equipment to control the sample temperature of cell block with auto-sample changer. It is required to develop a control software for this purpose. In addition, softwares of the aquisition and analysis for SANS instrument must be developed and supplied in order to function properly. PS/PI block copolymer research in NIST will provide the general understanding of SANS instrument and instrument-related valuable informations such as standard sample for SANS and know-hows of the instrument building. The following are the results of this research. a. Construction of sample cell block. b. Software to control the temperature and auto-sample changer. c. Acquisition of the SANS data analysis routine and its modification for HANARO SANS. d. PS/PI block copolymer research in NIST. e. Calibration data of NIST and HANARO SANS for comparison. 39 figs., 2 tabs. (Author)

  12. Retrospective Analysis of NIST Standard Reference Material 1450, Fibrous Glass Board, for Thermal Insulation Measurements

    Science.gov (United States)

    Zarr, Robert R; Heckert, N Alan; Leigh, Stefan D

    2014-01-01

    Thermal conductivity data acquired previously for the establishment of Standard Reference Material (SRM) 1450, Fibrous Glass Board, as well as subsequent renewals 1450a, 1450b, 1450c, and 1450d, are re-analyzed collectively and as individual data sets. Additional data sets for proto-1450 material lots are also included in the analysis. The data cover 36 years of activity by the National Institute of Standards and Technology (NIST) in developing and providing thermal insulation SRMs, specifically high-density molded fibrous-glass board, to the public. Collectively, the data sets cover two nominal thicknesses of 13 mm and 25 mm, bulk densities from 60 kg·m−3 to 180 kg·m−3, and mean temperatures from 100 K to 340 K. The analysis repetitively fits six models to the individual data sets. The most general form of the nested set of multilinear models used is given in the following equation: λ(ρ,T)=a0+a1ρ+a2T+a3T3+a4e−(T−a5a6)2where λ(ρ,T) is the predicted thermal conductivity (W·m−1·K−1), ρ is the bulk density (kg·m−3), T is the mean temperature (K) and ai (for i = 1, 2, … 6) are the regression coefficients. The least squares fit results for each model across all data sets are analyzed using both graphical and analytic techniques. The prevailing generic model for the majority of data sets is the bilinear model in ρ and T. λ(ρ,T)=a0+a1ρ+a2T One data set supports the inclusion of a cubic temperature term and two data sets with low-temperature data support the inclusion of an exponential term in T to improve the model predictions. Physical interpretations of the model function terms are described. Recommendations for future renewals of SRM 1450 are provided. An Addendum provides historical background on the origin of this SRM and the influence of the SRM on external measurement programs. PMID:26601034

  13. Structural Metadata Research in the Ears Program

    Science.gov (United States)

    2005-01-01

    detecting structural information in the word stream (the so-called “structural MDE” portion of the EARS program); other MDE efforts on speaker ... diarization are overviewed in [13]. The rest of this paper is organized as follows. We describe the structural MDE tasks, performance measurement, and corpora...tems have only recently been introduced, with NIST reporting re- sults with the Wilcoxon signed rank test for speaker -level average score differences

  14. Neutron Interferometry at the National Institute of Standards and Technology

    International Nuclear Information System (INIS)

    Huber, M. G.; Sarenac, D.; Nsofini, J.; Pushin, D. A.; Arif, M.; Wood, C. J.; Cory, D. G.; Shahi, C. B.

    2015-01-01

    Neutron interferometry has proved to be a very precise technique for measuring the quantum mechanical phase of a neutron caused by a potential energy difference between two spatially separated neutron paths inside interferometer. The path length inside the interferometer can be many centimeters (and many centimeters apart) making it very practical to study a variety of samples, fields, potentials, and other macroscopic medium and quantum effects. The precision of neutron interferometry comes at a cost; neutron interferometers are very susceptible to environmental noise that is typically mitigated with large, active isolated enclosures. With recent advances in quantum information processing especially quantum error correction (QEC) codes we were able to demonstrate a neutron interferometer that is insensitive to vibrational noise. A facility at NIST’s Center for Neutron Research (NCNR) has just been commissioned with higher neutron flux than the NCNR’s older interferometer setup. This new facility is based on QEC neutron interferometer, thus improving the accessibility of neutron interferometry to the greater scientific community and expanding its applications to quantum computing, gravity, and material research

  15. 76 FR 56165 - Soliciting Input on Research and Development Priorities for Desirable Features of a Nationwide...

    Science.gov (United States)

    2011-09-12

    ...'' of cyber-infrastructure that would be relied upon to provide truly essential services in the event of a catastrophic cyber-attack.\\9\\ Please comment on how NIST should pursue this recommendation. Among...

  16. 78 FR 13325 - Proposed Information Collection; Comment Request; Research on Evacuating Persons With Mobility...

    Science.gov (United States)

    2013-02-27

    ... DEPARTMENT OF COMMERCE National Institute of Standards and Technology Proposed Information... Institute of Standards and Technology (NIST), Commerce. ACTION: Notice. SUMMARY: The Department of Commerce... how building occupants with mobility impairments currently evacuate multi-story buildings in the...

  17. A neutronics methodology for the NIST research reactor based on MCNPX

    International Nuclear Information System (INIS)

    Hanson, Albert; Diamond, David

    2011-01-01

    A methodology for calculating inventories for the NBSR has been developed using the MCNPX computer code with the BURN option. A major advantage of the present methodology over the previous methodology, where MONTEBURNS and MCNP5 were used, is that more materials can be included in the model. The NBSR has 30 fuel elements each with a 17.8 cm (7 in) gap in the middle of the fuel. In the startup position, the shim control arms are partially inserted in the top half of the core. During the 38.5 day cycle, the shim arms are slowly removed to their withdrawn (horizontal) positions. This movement of shim arms causes asymmetries between the burnup of the fuel in the upper and lower halves and across the line of symmetry for the fuel loading. With the MONTEBURNS analyses there was a limitation to the number of materials that could be analyzed so 15 materials in the top half of the core and 15 materials in the bottom half of the core were used, and a half-core (east-west) symmetry was assumed. Since MCNPX allows more materials, this east-west symmetry was not necessary and the core was represented with 60 different materials. The methodology for developing the inventories is presented along with comparisons of neutronic parameters calculated with the previous and present sets of inventories. (author)

  18. A Neutronics Methodology for the NIST Research Reactor Based on MCNXP

    International Nuclear Information System (INIS)

    Hanson, A.; Diamond, D.

    2011-01-01

    A methodology for calculating inventories for the NBSR has been developed using the MCNPX computer code with the BURN option. A major advantage of the present methodology over the previous methodology, where MONTEBURNS and MCNP5 were used, is that more materials can be included in the model. The NBSR has 30 fuel elements each with a 17.8 cm (7 in) gap in the middle of the fuel. In the startup position, the shim control arms are partially inserted in the top half of the core. During the 38.5 day cycle, the shim arms are slowly removed to their withdrawn (horizontal) positions. This movement of shim arms causes asymmetries between the burnup of the fuel in the upper and lower halves and across the line of symmetry for the fuel loading. With the MONTEBURNS analyses there was a limitation to the number of materials that could be analyzed so 15 materials in the top half of the core and 15 materials in the bottom half of the core were used, and a half-core (east-west) symmetry was assumed. Since MCNPX allows more materials, this east-west symmetry was not necessary and the core was represented with 60 different materials. The methodology for developing the inventories is presented along with comparisons of neutronic parameters calculated with the previous and present sets of inventories.

  19. Mercury Continuous Emmission Monitor Calibration

    Energy Technology Data Exchange (ETDEWEB)

    John Schabron; Eric Kalberer; Ryan Boysen; William Schuster; Joseph Rovani

    2009-03-12

    Mercury continuous emissions monitoring systems (CEMs) are being implemented in over 800 coal-fired power plant stacks throughput the U.S. Western Research Institute (WRI) is working closely with the Electric Power Research Institute (EPRI), the National Institute of Standards and Technology (NIST), and the Environmental Protection Agency (EPA) to facilitate the development of the experimental criteria for a NIST traceability protocol for dynamic elemental mercury vapor calibrators/generators. These devices are used to calibrate mercury CEMs at power plant sites. The Clean Air Mercury Rule (CAMR) which was published in the Federal Register on May 18, 2005 and vacated by a Federal appeals court in early 2008 required that calibration be performed with NIST-traceable standards. Despite the vacature, mercury emissions regulations in the future will require NIST traceable calibration standards, and EPA does not want to interrupt the effort towards developing NIST traceability protocols. The traceability procedures will be defined by EPA. An initial draft traceability protocol was issued by EPA in May 2007 for comment. In August 2007, EPA issued a conceptual interim traceability protocol for elemental mercury calibrators. The protocol is based on the actual analysis of the output of each calibration unit at several concentration levels ranging initially from about 2-40 {micro}g/m{sup 3} elemental mercury, and in the future down to 0.2 {micro}g/m{sup 3}, and this analysis will be directly traceable to analyses by NIST. The EPA traceability protocol document is divided into two separate sections. The first deals with the qualification of calibrator models by the vendors for use in mercury CEM calibration. The second describes the procedure that the vendors must use to certify the calibrators that meet the qualification specifications. The NIST traceable certification is performance based, traceable to analysis using isotope dilution inductively coupled plasma

  20. Post hoc interlaboratory comparison of single particle ICP-MS size measurements of NIST gold nanoparticle reference materials.

    Science.gov (United States)

    Montoro Bustos, Antonio R; Petersen, Elijah J; Possolo, Antonio; Winchester, Michael R

    2015-09-01

    Single particle inductively coupled plasma-mass spectrometry (spICP-MS) is an emerging technique that enables simultaneous measurement of nanoparticle size and number quantification of metal-containing nanoparticles at realistic environmental exposure concentrations. Such measurements are needed to understand the potential environmental and human health risks of nanoparticles. Before spICP-MS can be considered a mature methodology, additional work is needed to standardize this technique including an assessment of the reliability and variability of size distribution measurements and the transferability of the technique among laboratories. This paper presents the first post hoc interlaboratory comparison study of the spICP-MS technique. Measurement results provided by six expert laboratories for two National Institute of Standards and Technology (NIST) gold nanoparticle reference materials (RM 8012 and RM 8013) were employed. The general agreement in particle size between spICP-MS measurements and measurements by six reference techniques demonstrates the reliability of spICP-MS and validates its sizing capability. However, the precision of the spICP-MS measurement was better for the larger 60 nm gold nanoparticles and evaluation of spICP-MS precision indicates substantial variability among laboratories, with lower variability between operators within laboratories. Global particle number concentration and Au mass concentration recovery were quantitative for RM 8013 but significantly lower and with a greater variability for RM 8012. Statistical analysis did not suggest an optimal dwell time, because this parameter did not significantly affect either the measured mean particle size or the ability to count nanoparticles. Finally, the spICP-MS data were often best fit with several single non-Gaussian distributions or mixtures of Gaussian distributions, rather than the more frequently used normal or log-normal distributions.

  1. Evaluation and compilation of DOE waste package test data

    International Nuclear Information System (INIS)

    Interrante, C.G.; Escalante, E.; Fraker, A.C.

    1990-11-01

    This report summarizes evaluations by the National Institute of Standards and Technology (NIST) of Department of Energy (DOE) activities on waste packages designed for containment of radioactive high-level nuclear waste (HLW) for the six-month period August 1988 through January 1989. Included are reviews of related materials research and plans, activities for the DOE Materials Characterization Center, information on the Yucca Mountain Project, and other information regarding supporting research and special assistance. NIST comments are given on the Yucca Mountain Consultation Draft Site Characterization Plan (CDSCP) and on the Waste Compliance Plan for the West Valley Demonstration Project (WVDP) High-Level Waste (HLW) Form. 3 figs

  2. Realization of New and Enhanced Materials Properties through Nanostructural Control

    National Research Council Canada - National Science Library

    Lee, Charles

    2003-01-01

    ...) transmitter/receiver systems. During this period of time, the Dalton research group served as the national resource for state-of-the-art electro-optic materials providing materials to DoD laboratories, DoE labs, NIST researchers...

  3. Realization of New and Enhanced Materials Properties Through Nanostructural Control

    National Research Council Canada - National Science Library

    Dalton, Larry

    2006-01-01

    ... transmitter/receiver systems. During this period of time, the Dalton research group served as the national resource for state-of-the-art electro-optic materials providing materials to DoD laboratories, DoE labs, NIST researchers...

  4. University of Maryland MRSEC - Collaborations

    Science.gov (United States)

    . University of Maryland Materials Research Science and Engineering Center Home About Us Leadership , National Nanotechnology Lab, Neocera, NIST, Rowan University, Rutgers University, Seagate, Tokyo Tech

  5. Research on network information security model and system construction

    OpenAIRE

    Wang Haijun

    2016-01-01

    It briefly describes the impact of large data era on China’s network policy, but also brings more opportunities and challenges to the network information security. This paper reviews for the internationally accepted basic model and characteristics of network information security, and analyses the characteristics of network information security and their relationship. On the basis of the NIST security model, this paper describes three security control schemes in safety management model and the...

  6. IGORR 1: Proceedings of the 1. meeting of the International Group On Research Reactors

    Energy Technology Data Exchange (ETDEWEB)

    West, C D [comp.

    1990-05-01

    Descriptions of the ongoing projects presented at this Meeting were concerned with: New Research Reactor FRM-II at Munich; MITR-II reactor; The Advanced. Neutron Source (ANS) Project; The high Flux Reactor Petten, Status and Prospects; The High Flux Beam Reactor Instrumentation Upgrade; BER-II Upgrade; The BR2 Materials Testing Reactor Past, Ongoing and Under-Study Upgrades; The ORPHEE, Reactor Current Status and Proposed Enhancement of Experimental Variabilities; Construction of the Upgraded JRR-3; Status of the University of Missouri-Columbia Research Reactor Upgrade; the Reactor and Cold Neutron Facility at NIST; Upgrade of Materials Irradiation Facilities in HFIR; Backfitting of the FRG Reactors; University Research Reactors in the United States; and Organization of the ITER Project - Sharing of Informational Procurements. Topics of interest were: Thermal-hydraulic tests and correlations, Corrosion tests and analytical models , Multidimensional kinetic analysis for small cores, Fuel plates fabrication, Fuel plates stability, Fuel irradiation, Burnable poison irradiation, Structural materials irradiation, Neutron guides irradiation, Cold Source materials irradiation, Cold Source LN{sub 2} test, Source LH2-H{sub 2}O reaction (H or D), Instrumentation upgrading and digital control system, Man-machine interface.

  7. IGORR 1: Proceedings of the 1. meeting of the International Group On Research Reactors

    International Nuclear Information System (INIS)

    West, C.D.

    1990-05-01

    Descriptions of the ongoing projects presented at this Meeting were concerned with: New Research Reactor FRM-II at Munich; MITR-II reactor; The Advanced. Neutron Source (ANS) Project; The high Flux Reactor Petten, Status and Prospects; The High Flux Beam Reactor Instrumentation Upgrade; BER-II Upgrade; The BR2 Materials Testing Reactor Past, Ongoing and Under-Study Upgrades; The ORPHEE, Reactor Current Status and Proposed Enhancement of Experimental Variabilities; Construction of the Upgraded JRR-3; Status of the University of Missouri-Columbia Research Reactor Upgrade; the Reactor and Cold Neutron Facility at NIST; Upgrade of Materials Irradiation Facilities in HFIR; Backfitting of the FRG Reactors; University Research Reactors in the United States; and Organization of the ITER Project - Sharing of Informational Procurements. Topics of interest were: Thermal-hydraulic tests and correlations, Corrosion tests and analytical models , Multidimensional kinetic analysis for small cores, Fuel plates fabrication, Fuel plates stability, Fuel irradiation, Burnable poison irradiation, Structural materials irradiation, Neutron guides irradiation, Cold Source materials irradiation, Cold Source LN 2 test, Source LH2-H 2 O reaction (H or D), Instrumentation upgrading and digital control system, Man-machine interface

  8. VERITAS: Versatile Triple-Axis Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sung Il

    2006-04-15

    Korea Atomic Energy Research Institute is planning to build a cold neutron triple-axis spectrometer at HANARO, the 30 MW research reactor. The spectrometer is expected to be completed in 2008 with the following configuration from the upstream to the downstream. Guide Supermirror m = 2, In-pile Straight Section, {approx} 5 m Curved Guide, {approx} 26 m w/ R 1500 m Straight Guide before the Instrument, {approx} 40 m Filters PG and Be Neutron Velocity Selector (Future) Monochromators Vertically Focusing Monochromators PG(002) and Heusler(111) Doubly Focusing Monochromators (Future) Monochromator-Sample Distance 2 m Collimation C1 Soller Collimators, 20', 40' 80'Beam Height at the Sample Table 1.5 m Sample-Analyzer Distance 1.0 m Collimation C2 Soller Collimators, 20', 40', 80' Radial Collimator Analyzers Horizontally Focusing Analyzers w/ Fixed Vertical Focusing PG(002) and Heusler(111) Analyzer-Detector Distance 0.5 m Detectors 5 cm Tube Detector 25 cm wide Position Sensitive Detector Once completed, the neutron flux at sample is expected to surpass that of SPINS at NCNR, making this instrument one of the most powerful 2nd generation cold neutron triple-axis spectrometers in the world.

  9. VERITAS: Versatile Triple-Axis Spectrometer

    International Nuclear Information System (INIS)

    Park, Sung Il

    2006-04-01

    Korea Atomic Energy Research Institute is planning to build a cold neutron triple-axis spectrometer at HANARO, the 30 MW research reactor. The spectrometer is expected to be completed in 2008 with the following configuration from the upstream to the downstream. Guide Supermirror m = 2, In-pile Straight Section, ∼ 5 m Curved Guide, ∼ 26 m w/ R 1500 m Straight Guide before the Instrument, ∼ 40 m Filters PG and Be Neutron Velocity Selector (Future) Monochromators Vertically Focusing Monochromators PG(002) and Heusler(111) Doubly Focusing Monochromators (Future) Monochromator-Sample Distance 2 m Collimation C1 Soller Collimators, 20', 40' 80'Beam Height at the Sample Table 1.5 m Sample-Analyzer Distance 1.0 m Collimation C2 Soller Collimators, 20', 40', 80' Radial Collimator Analyzers Horizontally Focusing Analyzers w/ Fixed Vertical Focusing PG(002) and Heusler(111) Analyzer-Detector Distance 0.5 m Detectors 5 cm Tube Detector 25 cm wide Position Sensitive Detector Once completed, the neutron flux at sample is expected to surpass that of SPINS at NCNR, making this instrument one of the most powerful 2nd generation cold neutron triple-axis spectrometers in the world

  10. 77 FR 68103 - National Construction Safety Team Advisory Committee Meeting

    Science.gov (United States)

    2012-11-15

    ... Standards and Technology (NIST) Disaster and Failure Studies Program, receive NIST's response to the... posted on the NIST Web site at http://www.nist.gov/el/disasterstudies/ncst/ . DATES: The NCST Advisory.... FOR FURTHER INFORMATION CONTACT: Eric Letvin, Director, Disaster and Failure Studies Program, 100...

  11. 15 CFR 296.22 - Award criteria.

    Science.gov (United States)

    2010-01-01

    ... STANDARDS AND TECHNOLOGY, DEPARTMENT OF COMMERCE NIST EXTRAMURAL PROGRAMS TECHNOLOGY INNOVATION PROGRAM The... research will not be conducted within a reasonable time period in the absence of financial assistance from... to support the proposal; (c) The proposal explains the novelty of the research (technology) and...

  12. U.S. Government Funding of Cooperative Research and Development in North America,

    Science.gov (United States)

    1999-01-01

    Consejo Nacional de Ciencia y Tecnologia (CONACYT) reports that it has signed agreements with U.S. government agencies, such as NSF, NIH, and NIST, to...government agency Consejo Nacional de Ciencia y Tec- nologia for providing feedback and validation of much of the information collected in this report...David Mussington and Beth Lachman. ABBREVIATIONS CDC Centers for Disease Control and Prevention CONACYT Consejo Nacional de Ciencia y Tecnologfa

  13. Elemental and Isotopic Analysis of Uranium Oxide an NIST Glass Standards by FEMTOSECOND-LA-ICP-MIC-MS

    International Nuclear Information System (INIS)

    Ebert, Chris; Zamzow, Daniel S.; McBay, Eddie H.; Bostick, Debra A.; Bajic, Stanley J.; Baldwin, David P.; Houk, R.S.

    2009-01-01

    The objective of this work was to test and demonstrate the analytical figures of merit of a femtosecond-laser ablation (fs-LA) system coupled with an inductively coupled plasma-multi-ion collector-mass spectrometer (ICP-MIC-MS). The mobile fs-LA sampling system was designed and assembled at Ames Laboratory and shipped to Oak Ridge National Laboratory (ORNL), where it was integrated with an ICP-MIC-MS. The test period of the integrated systems was February 2-6, 2009. Spatially-resolved analysis of particulate samples is accomplished by 100-shot laser ablation using a fs-pulsewidth laser and monitoring selected isotopes in the resulting ICP-MS transient signal. The capability of performing high sensitivity, spatially resolved, isotopic analyses with high accuracy and precision and with virtually no sample preparation makes fs-LA-ICP-MIC-MS valuable for the measurement of actinide isotopes at low concentrations in very small samples for nonproliferation purposes. Femtosecond-LA has been shown to generate particles from the sample that are more representative of the bulk composition, thereby minimizing weaknesses encountered in previous work using nanosecond-LA (ns-LA). The improvement of fs- over ns-LA sampling arises from the different mechanisms for transfer of energy into the sample in these two laser pulse-length regimes. The shorter duration fs-LA pulses induce less heating and cause less damage to the sample than the longer ns pulses. This results in better stoichiometric sampling (i.e., a closer correlation between the composition of the ablated particles and that of the original solid sample), which improves accuracy for both intra- and inter-elemental analysis. The primary samples analyzed in this work are (a) solid uranium oxide powdered samples having different 235 U to 238 U concentration ratios, and (b) glass reference materials (NIST 610, 612, 614, and 616). Solid uranium oxide samples containing 235 U in depleted, natural, and enriched abundances were

  14. Metastability-exchange optical pumping of 3He for neutron polarizers

    International Nuclear Information System (INIS)

    Gentile, T.R.; Thompson, A.K.; Snow, W.M.

    1995-01-01

    Research is underway at NIST and IU to develop neutron polarizers that are based on polarized 3 He. Such polarizers rely on the strong spin dependence of the cross section for neutron capture by polarized 3 He. Two methods can produce the high density of polarized 3 He gas (10 19 -10 20 cm -3 ) required for an effective neutron polarizer: spin-exchange optical pumping, which is performed directly at high pressure (1-10 bar), and metastability-exchange optical pumping, in which the gas is polarized at low pressure (1 mbar) and then compressed. While we are pursuing both methods, progress in the metastable method will be discussed. The features of the metastable method are the high rate at which the gas can be polarized and the inherent separation of the optical pumping and target cells. In a landmark achievement, researchers at the Univ. of Mainz have developed a piston compressor that can fill a 130 cm 3 cell to a pressure of 7 bar of 45% polarized 3 He gas in 2 hours. We plan to develop a compressor and test it at the NIST Cold Neutron Research Facility. We have constructed a metastable-pumping apparatus at NIST and have obtained 76% polarization with a pumping rate of 1.2 x 10 18 atoms/sec in a 0.4 mbar, 270 cm 3 cell

  15. Applied research on environmental pollution using INAA. A study on the environmental indicator analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Nak Bae; Lee, Gil Yong; Yoon, Yoon Yul; Chon, Sang Ki [Korea Institute of Geology Mining and Research, Taejon (Korea, Republic of)

    1995-08-01

    Among the many kinds of environmental indicator samples such as moss, lichen, pine needle, pine needle was selected as a bio-monitor and collected sample was divided two groups and one was washed with 1% hydrochloric acid to remove the elements deposited on surface. Trace elements in pine needle were analyzed by the decay time of each nuclide. Analytical accuracy was tested by analyzing NIST SRM 1575 pine needle. Results are follows: (1) Environmental indicator as a bio-monitor pine needle was selected. (2) The content difference of the trace elements between sampling period was monitored. And as content was varied with sampling time. (3) To monitor the influence of atmospheric deposition the surface of pine needle was washed with 1% hydrochloric acid. Therefore, As, Ce, La, Na, W, and Zn contents were decreased by washing. (4) Non-destructive INAA (Instrumental Neutron Activation Analysis) technique was developed for the determination of trace elements in environmental samples. (5) Analytical accuracy was tested by analyzing NIST SRM 1575 pine needle, and the accuracy was well agreed within 10% deviation. summarized. (author). 18 refs., 8 figs., 5 tabs.

  16. Elemental analysis using instrumental neutron activation analysis and inductively coupled plasma atomic emission spectrometry: a comparative study

    International Nuclear Information System (INIS)

    Chung, Yong Sam; Choi, Kwang Soon; Moon, Jong Hwa; Kim, Sun Ha; Lim, Jong Myoung; Kim, Young Jin; Quraishi, Shamshad Begum

    2003-05-01

    Elemental analyses for certified reference materials were carried out using instrumental neutron activation analysis and inductively coupled plasma-atomic emission spectrometry. Five Certified Reference Materials (CRM) were selected for the study on comparative analysis of environmental samples. The CRM are Soil (NIST SRM 2709), Coal fly ash (NIST SRM 1633a), urban dust (NIST SRM 1649a) and air particulate on filter media (NIST SRM 2783 and human hair (GBW 09101)

  17. Charpy impact test results on five materials and NIST verification specimens using instrumented 2-mm and 8-mm strikers

    International Nuclear Information System (INIS)

    Nanstad, R.K.; Sokolov, M.A.

    1995-01-01

    The Heavy-Section Steel Irradiation Program at Oak Ridge National Laboratory is involved in two cooperative projects, with international participants, both of which involve Charpy V-notch impact tests with instrumented strikers of 2mm and 8mm radii. Two heats of A 533 grade B class I pressure vessel steel and a low upper-shelf (LUS) submerged-arc (SA) weld were tested on the same Charpy machine, while one heat of a Russian Cr-Mo-V forging steel and a high upper-shelf (HUS) SA weld were tested on two different machines. The number of replicate tests at any one temperature ranged from 2 to 46 specimens. Prior to testing with each striker, verification specimens at the low, high, and super high energy levels from the National Institute of Standards and Technology (NIST) were tested. In the two series of verification tests, the tests with the 2mm striker met the requirements at the low and high energy levels but not at the super high energy. For one plate, the 2mm striker showed somewhat higher average absorbed energies than those for the 8-mm striker at all three test temperatures. For the second plate and the LUS weld, however, the 2mm striker showed somewhat lower energies at both test temperatures. For the Russian forging steel and the HUS weld, tests were conducted over a range of temperatures with tests at one laboratory using the 8mm striker and tests at a second laboratory using the 2mm striker. Lateral expansion was measured for all specimens and the results are compared with the absorbed energy results. The overall results showed generally good agreement (within one standard deviation) in energy measurements by the two strikers. Load-time traces from the instrumented strikers were also compared and used to estimate shear fracture percentage. Four different formulas from the European Structural Integrity Society draft standard for instrumented Charpy test are compared and a new formula is proposed for estimation of percent shear from the force-time trace

  18. Notification: Audit of Security Categorization for EPA Systems That Handle Hazardous Material Information

    Science.gov (United States)

    Project #OA-FY18-0089, January 8, 2018. The OIG plans to begin preliminary research to determine whether the EPA classified the sensitivity of data for systems that handle hazardous waste material information as prescribed by NIST.

  19. Bilateral key comparison SIM.T-K6.1 on humidity standards in the dew/frost-point temperature range from -25 °C to +20 °C

    Science.gov (United States)

    Meyer, C. W.; Hill, K. D.

    2015-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the National Research Council (NRC, Canada) between December 2014 and April 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and NRC and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and NRC. This paper is the final report of the comparison including analysis of the uncertainty of measurement results. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT WG-KC, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. 77 FR 8217 - Evaluating the Usability of Electronic Health Record (EHR) Systems

    Science.gov (United States)

    2012-02-14

    ... usability of health information technology (HIT) systems, EHRs in particular, and performance-oriented user... the usability of health information technology (HIT) systems. NIST research is designed to: (1... DEPARTMENT OF COMMERCE National Institute of Standards and Technology [Docket No. 120123059-2058...

  1. 76 FR 64326 - National Construction Safety Team Advisory Committee Meeting

    Science.gov (United States)

    2011-10-18

    ... update the Committee on the status of the National Institute of Standards and Technology (NIST) Disaster... business. The final agenda will be posted on the NIST Web site at http://www.nist.gov/el/disasterstudies... INFORMATION section of this notice. FOR FURTHER INFORMATION CONTACT: Eric Letvin, Director, Disaster and...

  2. Improving measurement quality assurance for photon irradiations at Department of Energy facilities. Final technical report

    International Nuclear Information System (INIS)

    1996-01-01

    For radiation-instrument calibration to be generally acceptable throughout the US, direct or indirect traceability to a primary standard is required. In most instances, one of the primary standards established at NIST is employed for this purpose. The Department of Energy Laboratory Accreditation Program (DOELAP) is an example of a program employing dosimetry based on the NIST primary photon-, beta particle- and neutron-dosimetry standards. The NIST primary dosimetry standards for bremsstrahlung were first established in the 1950s. They have been updated since then on several occasions. In the 1970s, Technical Committee 85 of the International Standards Organization (ISO) started its work on establishing sets of internationally acceptable, well-characterized photon beams for the calibration of radiation-protection instruments. It is the intent of this paper to make a detailed comparison between the current NIST and the most up-to-date ISO techniques. At present, 41 bremsstrahlung techniques are specified in ISO 4037 while NIST supports a total of 32 techniques. Given the existing equivalences, it makes sense to try to extend the NIST techniques to cover more of the ISO Narrow Spectrum and High Air-Kerma Rate Series. These extensions will also allow the possibility for use of ISO beam techniques in future revisions of the DOELAP standard, which has been suggested by DOE. To this end, NIST was funded by DOE to procure material and make adaptations to the existing NIST x-ray calibration ranges to allow NIST to have the capability of producing all the ISO bremsstrahlung techniques. The following sections describe the steps that were taken to achieve this

  3. 76 FR 539 - Alternative Personnel Management System (APMS) at the National Institute of Standards and Technology

    Science.gov (United States)

    2011-01-05

    ...,'' NIST accomplished the following: NIST is more competitive for talent; NIST retained more top performers... title 5, United States Code, provides agencies with the authority to appoint candidates directly to jobs... subsection titled: ``Rating and Ranking'' is deleted. [FR Doc. 2010-33307 Filed 1-4-11; 8:45 am] BILLING CODE...

  4. 77 FR 71169 - Smart Grid Advisory Committee Meeting

    Science.gov (United States)

    2012-11-29

    ... cybersecurity coordination and the NIST Smart Grid Program Plan. The agenda may change to accommodate Committee business. The final agenda will be posted on the Smart Grid Web site at http://www.nist.gov/smartgrid... receive presentations on cybersecurity coordination and the NIST Smart Grid Program Plan. The agenda may...

  5. Atomic Spectra Database (ASD)

    Science.gov (United States)

    SRD 78 NIST Atomic Spectra Database (ASD) (Web, free access)   This database provides access and search capability for NIST critically evaluated data on atomic energy levels, wavelengths, and transition probabilities that are reasonably up-to-date. The NIST Atomic Spectroscopy Data Center has carried out these critical compilations.

  6. MACS low-background doubly focusing neutron monochromator

    CERN Document Server

    Smee, S A; Scharfstein, G A; Qiu, Y; Brand, P C; Anand, D K; Broholm, C L

    2002-01-01

    A novel doubly focusing neutron monochromator has been developed as part of the Multi-Analyzer Crystal Spectrometer (MACS) at the NIST Center for Neutron Research. The instrument utilizes a unique vertical focusing element that enables active vertical and horizontal focusing with a large, 357-crystal (1428 cm sup 2), array. The design significantly reduces the amount of structural material in the beam path as compared to similar instruments. Optical measurements verify the excellent focal performance of the device. Analytical and Monte Carlo simulations predict that, when mounted at the NIST cold-neutron source, the device should produce a monochromatic beam (DELTA E=0.2 meV) with flux phi>10 sup 8 n/cm sup 2 s. (orig.)

  7. 76 FR 39843 - Submission for OMB Review; Comment Request

    Science.gov (United States)

    2011-07-07

    ...: National Institute of Standards and Technology (NIST). Title: Usage of Elevators for Occupant Evacuation...- story buildings in the United States during fire emergencies. This research aims to summarize emergency... emergency procedures for multi-story buildings) from existing buildings in the United States, including...

  8. 78 FR 32365 - Submission for OMB Review; Comment Request

    Science.gov (United States)

    2013-05-30

    ...: National Institute of Standards and Technology (NIST). Title: Research on Evacuating Persons with Mobility... understanding of how building occupants with mobility impairments currently evacuate multi-story buildings in... in charge of developing emergency procedures for multi-story buildings in the United States...

  9. 48 CFR 1804.470-3 - IT security requirements.

    Science.gov (United States)

    2010-10-01

    ... the provisioning of services or products (e.g., research and development, engineering, manufacturing... physical or electronic (i.e., authentication level 2 and above as defined in NIST Special Publication 800-63, Electronic Authentication Guideline) access to NASA's computer systems, networks, or IT...

  10. 78 FR 47674 - Genome in a Bottle Consortium-Progress and Planning Workshop

    Science.gov (United States)

    2013-08-06

    ... quantitative performance metrics for confidence in variant calling. These standards and quantitative..., reproducible research and regulated applications in the clinic. On April 13, 2012, NIST convened the workshop... Material (RM) Selection and Design: select appropriate sources for whole genome RMs and identify or design...

  11. 76 FR 59112 - Announcing an Open Meeting of the Information Security and Privacy Advisory Board

    Science.gov (United States)

    2011-09-23

    ... by the Computer Security Act of 1987 (Pub. L. 100-235) and amended by the Federal Information... NIST on security and privacy issues pertaining to federal computer systems. Details regarding the ISPAB... security research, --Presentation from National Protection and Programs Directorate, DHS, on the white...

  12. Business Case Analysis of the Marine Corps Base Pendleton Virtual Smart Grid

    Science.gov (United States)

    2017-06-01

    is searching for answers in energy-efficient technology . This study discusses the benefits of using power-modeling software to manage Advanced ...under NIST. 7 Figure 3. A History of NIST and the Smart Grid. Source: NIST (2014). The extension of smart grid technology to include...NAVAL POSTGRADUATE SCHOOL MONTEREY, CALIFORNIA THESIS Approved for public release. Distribution is unlimited. BUSINESS CASE

  13. Testing the applicability of the k 0-NAA method at the MINT's TRIGA MARK II reactor

    International Nuclear Information System (INIS)

    Siong, Wee Boon; Dung, Ho Manh; Wood, Ab. Khalik; Salim, Nazaratul Ashifa Abd.; Elias, Md. Suhaimi

    2006-01-01

    The Analytical Chemistry Laboratory at MINT is using the NAA technique since 1980s and is the only laboratory in Malaysia equipped with a research reactor, namely the TRIGA MARK II. Throughout the years the development of NAA technique has been very encouraging and was made applicable to a wide range of samples. At present, the k 0 method has become the preferred standardization method of NAA (k 0 -NAA) due to its multi-elemental analysis capability without using standards. Additionally, the k 0 method describes NAA in physically and mathematically understandable definitions and is very suitable for computer evaluation. Eventually, the k 0 -NAA method has been adopted by MINT in 2003, in collaboration with the Nuclear Research Institute (NRI), Vietnam. The reactor neutron parameters (α and f) for the pneumatic transfer system and for the rotary rack at various locations, as well as the detector efficiencies were determined. After calibration of the reactor and the detectors, the implemented k 0 method was validated by analyzing some certified reference materials (including IAEA Soil 7, NIST 1633a, NIST 1632c, NIST 1646a and IAEA 140/TM). The analysis results of the CRMs showed an average u score well below the threshold value of 2 with a precision of better than ±10% for most of the elemental concentrations obtained, validating herewith the introduction of the k 0 -NAA method at the MINT

  14. Testing the applicability of the k0-NAA method at the MINT's TRIGA MARK II reactor

    Science.gov (United States)

    Siong, Wee Boon; Dung, Ho Manh; Wood, Ab. Khalik; Salim, Nazaratul Ashifa Abd.; Elias, Md. Suhaimi

    2006-08-01

    The Analytical Chemistry Laboratory at MINT is using the NAA technique since 1980s and is the only laboratory in Malaysia equipped with a research reactor, namely the TRIGA MARK II. Throughout the years the development of NAA technique has been very encouraging and was made applicable to a wide range of samples. At present, the k0 method has become the preferred standardization method of NAA ( k0-NAA) due to its multi-elemental analysis capability without using standards. Additionally, the k0 method describes NAA in physically and mathematically understandable definitions and is very suitable for computer evaluation. Eventually, the k0-NAA method has been adopted by MINT in 2003, in collaboration with the Nuclear Research Institute (NRI), Vietnam. The reactor neutron parameters ( α and f) for the pneumatic transfer system and for the rotary rack at various locations, as well as the detector efficiencies were determined. After calibration of the reactor and the detectors, the implemented k0 method was validated by analyzing some certified reference materials (including IAEA Soil 7, NIST 1633a, NIST 1632c, NIST 1646a and IAEA 140/TM). The analysis results of the CRMs showed an average u score well below the threshold value of 2 with a precision of better than ±10% for most of the elemental concentrations obtained, validating herewith the introduction of the k0-NAA method at the MINT.

  15. Quantitative measurement of the chemical composition of geological standards with a miniature laser ablation/ionization mass spectrometer designed for in situ application in space research

    International Nuclear Information System (INIS)

    Neuland, M B; Riedo, A; Tulej, M; Wurz, P; Grimaudo, V; Moreno-García, P; Mezger, K

    2016-01-01

    A key interest of planetary space missions is the quantitative determination of the chemical composition of the planetary surface material. The chemical composition of surface material (minerals, rocks, soils) yields fundamental information that can be used to answer key scientific questions about the formation and evolution of the planetary body in particular and the Solar System in general. We present a miniature time-of-flight type laser ablation/ionization mass spectrometer (LMS) and demonstrate its capability in measuring the elemental and mineralogical composition of planetary surface samples quantitatively by using a femtosecond laser for ablation/ionization. The small size and weight of the LMS make it a remarkable tool for in situ chemical composition measurements in space research, convenient for operation on a lander or rover exploring a planetary surface. In the laboratory, we measured the chemical composition of four geological standard reference samples USGS AGV-2 Andesite, USGS SCo-l Cody Shale, NIST 97b Flint Clay and USGS QLO-1 Quartz Latite with LMS. These standard samples are used to determine the sensitivity factors of the instrument. One important result is that all sensitivity factors are close to 1. Additionally, it is observed that the sensitivity factor of an element depends on its electron configuration, hence on the electron work function and the elemental group in agreement with existing theory. Furthermore, the conformity of the sensitivity factors is supported by mineralogical analyses of the USGS SCo-l and the NIST 97b samples. With the four different reference samples, the consistency of the calibration factors can be demonstrated, which constitutes the fundamental basis for a standard-less measurement-technique for in situ quantitative chemical composition measurements on planetary surface. (paper)

  16. 78 FR 18322 - Smart Grid Advisory Committee Meeting

    Science.gov (United States)

    2013-03-26

    ... business. The final agenda will be posted on the Smart Grid Web site at http://www.nist.gov/smartgrid... standards, priorities, and gaps, on the overall direction, status, and health of the Smart Grid... direction of research and standards activities. Background information on the Committee is available at http...

  17. Aircraft Fire Sentry. Volume 2. Appendices

    Science.gov (United States)

    1993-01-01

    including New Mexico Engineering Research Institute (NMERI), National Institute of Standards and Technology (NIST), Wright-Patterson AFB, and AFESC at...Installation Remove the mounting bracket from the smoke alarm by depresing the release tab marked "PRESS" (see Figure 1. pg. 5). Pivot the bracket awey from and

  18. 75 FR 106 - Visiting Committee on Advanced Technology

    Science.gov (United States)

    2010-01-04

    ..., new product development, engineering, labor, education, management consulting, environment, and... update on NIST, a presentation on the strengthened NIST role in documentary standards, an overview of the...

  19. Cloud Service Provider Methods for Managing Insider Threats: Analysis Phase 1

    Science.gov (United States)

    2013-11-01

    of Standards and Technology (NIST) Special Publication 800-145 (NIST SP 800-145) defines three types of cloud services : Software as a Service ( SaaS ...among these three models. NIST SP 800-145 describes the three service models as follows: SaaS —The capability provided to the consumer is to use the...Cloud Service Provider Methods for Managing Insider Threats: Analysis Phase I Greg Porter November 2013 TECHNICAL NOTE CMU/SEI-2013-TN-020

  20. Cadmium contamination in cereal-based diets and diet ingredients

    International Nuclear Information System (INIS)

    Siitonen, P.H.; Thompson, H.C. Jr.

    1990-01-01

    Cereal-based diet and/or diet ingredient cadmium levels were determined by graphite furnace AAS. Cadmium contamination was 88.3 and 447 ppb in two cereal-based diets, 44.6 and 48.9 ppb in two purified diets, and ranged from less than 1.1 to 22,900 ppb in the ingredients of one cereal-based diet. The major source of cadmium contamination was attributed to the calcium supplement used for diet formulation. Comparative analyses of two purified diet samples and one cereal-based diet by the National Institute of Standards and Technology (NIST, formerly the National Bureau of Standards) and the National Center for Toxicological Research (NCTR) gave virtually identical results for Cd. A comparative study of Cd levels determined by flame and furnace AAS was also made by the NCTR and the NIST

  1. Intercomparison of IAEA airborne particulate matter reference material. Appendix 19

    International Nuclear Information System (INIS)

    Landsberger, Sheldon; Wu, De; Vermette, Stephen; Cizek, William

    1995-01-01

    Fifty air filters with fine and coarse fractions were prepared from NIST 2710 contaminated soil. Eighteen pairs were made and sent to seventeen laboratories of the CRP program on Applied Research on Air Pollution Using Nuclear-Related Analytical Techniques for elemental determination. The results of this intercomparison are discussed in this paper. (author)

  2. An assessment of 25-hydroxyvitamin D measurements in comparability studies conducted by the Vitamin D Metabolites Quality Assurance Program.

    Science.gov (United States)

    Bedner, Mary; Lippa, Katrice A; Tai, Susan S-C

    2013-11-15

    The National Institute of Standards and Technology (NIST), in collaboration with the National Institutes of Health Office of Dietary Supplements, established the first accuracy-based program for improving the comparability of vitamin D metabolite measurements, the Vitamin D Metabolites Quality Assurance Program. The study samples were human serum or plasma Standard Reference Materials (SRMs) with 25-hydroxyvitamin D values that were determined at NIST. Participants evaluated the materials using immunoassay (IA), liquid chromatography (LC) with mass spectrometric detection, and LC with ultraviolet absorbance detection. NIST evaluated the results for concordance within the participant community as well as trueness relative to the NIST value. For the study materials that contain mostly 25-hydroxyvitamin D3 (25(OH)D3),the coefficient of variation (CV) for the participant results was consistently in the range from 7% to 19%, and the median values were biased high relative to the NIST values. However, for materials that contain significant concentrations of both 25-hydroxyvitamin D2 (25(OH)D2) and 25(OH)D3, the median IA results were biased lower than both the LC and the NIST values, and the CV was as high as 28%. The first interlaboratory comparison results for SRM 972a Vitamin D Metabolites in Human Serum are also reported. Relatively large within-lab and between-lab variability hinders conclusive assessments of bias and accuracy. © 2013.

  3. Radionuclide traceability for U.S. Department of Energy Environmental Management Radioanalytical Services

    International Nuclear Information System (INIS)

    Morton, J.S.; McIntyre, T.I.

    2001-01-01

    In 1999, the Department of Energy Office of Environmental Management (DOE-EM) National Analytical Management Program (NAMP) established a Radiological Traceability Program (RTP) as a new initiative for the radioanalytical activities related to the environmental programs conducted throughout the DOE complex. The National Analytical Management Program entered into an interagency agreement with the National Institute of Standards and Technology (NIST) to establish traceability to the national standard for DOE-EM radioanalytical activities through the NIST/reference laboratory concept as described in ANSI N42.23-1996. Using the criteria established by the RTP, NAMP named two DOE-EM laboratories as reference or secondary laboratories and established a program with NIST that demonstrated the concept of traceability. In order to gain and maintain traceability to NIST, each reference laboratory must meet the performance criteria as defined by the RTP and NAMP. Traceability to NIST is tiered down to each radioanalytical laboratory (monitor or service) that successfully participates in the performance-evaluation programs offered by the reference laboratories. Essential to the RTP is the demonstration that the reference laboratories can produce performance-testing (PT) materials of high quality as well as analyze/verify the radionuclide concentration to the required accuracy and precision. Elements of the RTP and the program requirements of NIST and the reference laboratories are presented. (author)

  4. Use of composite materials for the determination of Cu, As, Mo, Cd and Sb in biological materials by radiochemical neutron activation analysis

    International Nuclear Information System (INIS)

    Lucanikova, M.; John, J.; Kucera, J.; Sebesta, F.

    2006-01-01

    New composite materials were developed and tested for determination of Cu, As, Mo, Cd, and Sb in biological materials by radiochemical neutron activation analysis (RNAA). The materials were prepared by incorporation of solid zinc diethyldithiocarbamate or liquid bis(2,4,4-trimethylpentyl)dithiophosphinic acid (CYANEX 301) into a polyacrylonitrile (PAN) binding matrix. The accuracy of the RNAA procedures was proved by analysis of NIST SRM-1515 Apple Leaves, NIST SRM-1577b Bovine Liver, and NIST SRM-1549 Non Fat Milk Powder. (author)

  5. MO-C-12A-01: Quantitative Imaging Initiatives: Why, Who, What, and How?

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, D [Duke University, Durham, NC (United States); Jackson, E; Clarke, L; Petrick, N; Russek, S [University of Wisconsin, Madison, WI (United States)

    2014-06-15

    Over the past decade, there has been an increasing focus on quantitative imaging (QI), which, according to one definition, is “the extraction of quantifiable features from medical images for the assessment of normal or the severity, degree of change, or status of a disease, injury, or chronic condition relative to normal” ( www.rsna.org/QIBA ). To achieve the goals of QI requires the development and standardization of data acquisition, data analysis, and data display techniques, as well as appropriate reporting structures. As such, successful implementation of QI relies heavily on expertise from the fields of medical physics, radiology, statistics, and informatics as well as collaboration from vendors of imaging acquisition, analysis, and reporting systems. When successfully implemented, QI techniques will provide image-derived metrics with known bias and variance that can be validated with anatomically and physiologically relevant measures, including treatment response, and the heterogeneity of that response, and outcome. Such non-invasive measures can then be used effectively in clinical and translational research as well as patient care. In addition to modality-specific QI efforts implemented by individual scientific organizations, national and international organizations, including the NCI, RSNA, FDA, and NIST, appreciating the tremendous potential of QI but also understanding the associated challenges, have become increasingly involved. This symposium session will focus on 1) introducing QI and illustrating why it is important, even though challenging, in both research and clinical applications, and 2) providing overviews of QI efforts from national and international organizations, including the RSNA, NCI, FDA, and NIST. Learning Objectives: Understand the importance and potential of QI in research and clinical applications. Understand key challenges of QI and current barriers to implementation. Understand the current QI efforts of several national and

  6. MO-C-12A-01: Quantitative Imaging Initiatives: Why, Who, What, and How?

    International Nuclear Information System (INIS)

    Sullivan, D; Jackson, E; Clarke, L; Petrick, N; Russek, S

    2014-01-01

    Over the past decade, there has been an increasing focus on quantitative imaging (QI), which, according to one definition, is “the extraction of quantifiable features from medical images for the assessment of normal or the severity, degree of change, or status of a disease, injury, or chronic condition relative to normal” ( www.rsna.org/QIBA ). To achieve the goals of QI requires the development and standardization of data acquisition, data analysis, and data display techniques, as well as appropriate reporting structures. As such, successful implementation of QI relies heavily on expertise from the fields of medical physics, radiology, statistics, and informatics as well as collaboration from vendors of imaging acquisition, analysis, and reporting systems. When successfully implemented, QI techniques will provide image-derived metrics with known bias and variance that can be validated with anatomically and physiologically relevant measures, including treatment response, and the heterogeneity of that response, and outcome. Such non-invasive measures can then be used effectively in clinical and translational research as well as patient care. In addition to modality-specific QI efforts implemented by individual scientific organizations, national and international organizations, including the NCI, RSNA, FDA, and NIST, appreciating the tremendous potential of QI but also understanding the associated challenges, have become increasingly involved. This symposium session will focus on 1) introducing QI and illustrating why it is important, even though challenging, in both research and clinical applications, and 2) providing overviews of QI efforts from national and international organizations, including the RSNA, NCI, FDA, and NIST. Learning Objectives: Understand the importance and potential of QI in research and clinical applications. Understand key challenges of QI and current barriers to implementation. Understand the current QI efforts of several national and

  7. 76 FR 3089 - Roundtable on Federal Government Engagement in Standards

    Science.gov (United States)

    2011-01-19

    ... standards for these new technology sectors are helping drive innovation, economic growth, and job creation... . Media inquiries should be directed to NIST Public and Business Affairs at 301-975-NIST or [email protected

  8. Functional and Behavioral Product Information Representation and Consistency Validation for Collaboration in Product Lifecycle Activities

    Science.gov (United States)

    Baysal, Mehmet Murat

    2012-01-01

    Information models that represent the function, assembly and behavior of artifacts are critical in the conceptual development of a product and its evaluation. Much research has been conducted in this area; however, existing models do not relate function, behavior and structure in a comprehensive and consistent way. In this work, NIST's Core…

  9. Mercury CEM Calibration

    Energy Technology Data Exchange (ETDEWEB)

    John Schabron; Joseph Rovani; Mark Sanderson

    2008-02-29

    Mercury continuous emissions monitoring systems (CEMS) are being implemented in over 800 coal-fired power plant stacks. The power industry desires to conduct at least a full year of monitoring before the formal monitoring and reporting requirement begins on January 1, 2009. It is important for the industry to have available reliable, turnkey equipment from CEM vendors. Western Research Institute (WRI) is working closely with the Electric Power Research Institute (EPRI), the National Institute of Standards and Technology (NIST), and the Environmental Protection Agency (EPA) to facilitate the development of the experimental criteria for a NIST traceability protocol for dynamic elemental mercury vapor generators. The generators are used to calibrate mercury CEMs at power plant sites. The Clean Air Mercury Rule (CAMR) which was published in the Federal Register on May 18, 2005 requires that calibration be performed with NIST-traceable standards (Federal Register 2007). Traceability procedures will be defined by EPA. An initial draft traceability protocol was issued by EPA in May 2007 for comment. In August 2007, EPA issued an interim traceability protocol for elemental mercury generators (EPA 2007). The protocol is based on the actual analysis of the output of each calibration unit at several concentration levels ranging initially from about 2-40 {micro}g/m{sup 3} elemental mercury, and in the future down to 0.2 {micro}g/m{sup 3}, and this analysis will be directly traceable to analyses by NIST. The document is divided into two separate sections. The first deals with the qualification of generators by the vendors for use in mercury CEM calibration. The second describes the procedure that the vendors must use to certify the generator models that meet the qualification specifications. The NIST traceable certification is performance based, traceable to analysis using isotope dilution inductively coupled plasma/mass spectrometry performed by NIST in Gaithersburg, MD. The

  10. 75 FR 33769 - Manufacturing Extension Partnership (MEP) Availability of Funds for Projects To Develop and...

    Science.gov (United States)

    2010-06-15

    ... to the long-term economic stability of the region. Please see the NIST MEP Web site, http://www.nist... region, and contribute to the long-term economic stability of the region. Competitive projects will use...

  11. 78 FR 57839 - Request for Information on Computer Security Incident Coordination (CSIC)

    Science.gov (United States)

    2013-09-20

    ...-02] Request for Information on Computer Security Incident Coordination (CSIC) AGENCY: National... Computer Security Incident Coordination. NIST experienced technical difficulties with receiving email... Technology (NIST) announced that it was soliciting comments relating to Computer Security Incident...

  12. Physics Laboratory technical activities, 1991. Final report

    International Nuclear Information System (INIS)

    Gebbie, K.B.

    1992-02-01

    The report summarizes research projects, measurement method development, calibration and testing, and data evaluation activities that were carried out during calendar year 1991 in the NIST Physics Laboratory. These activities fall in the areas of electron and optical physics, atomic physics, molecular physics, radiometric physics, quantum metrology, ionizing radiation, time and frequency, quantum physics, and fundamental constants

  13. Mobile Device Management in the DOD Enterprise Network: Factors for Risk Management, Integration, and It Acquisition

    Science.gov (United States)

    2013-03-01

    Administration NFC Near Field Communications NIST National Institute of Standards and Technology NPRST Navy Personnel Research, Studies, and Technology ...information technology (IT) system acquisition process to acquire a mobile device management (MDM) toolset to mitigate information assurance (IA) risks...method study to understand the concerns of federal information technology professionals who are knowledgeable on MDM and the acquisition

  14. Development of methods to examine the effects of atmospheric particulate matter (PM) on human peripheral blood leukocytes

    Science.gov (United States)

    Zussman, Lisa Ann

    In vitro methods to study the effect of atmospheric particulate matter (PM) on leukocyte function using human peripheral blood were developed. These methods were demonstrated using the blood of 1-5 individuals and National Institute of Standards and Technology (NIST) urban PM #1648, diesel PM #1650, silica PM, and a locally collected PM sample (New Jersey PM10). For the blood samples analyzed in this study NIST urban PM and New Jersey PM10 treatment mediated the release of granule contents from peripheral blood leukocytes and induced structural changes associated with degranulation. Flow cytometry revealed PM-induced changes in phagocytosis and cell structure associated with degranulation. Transmission electron microscopy confirmed NIST urban PM-induced cell structure changes were associated with PM internalization. Colorametric and electrophoretic methods showed no PM-induced release of primary granules and a slight PM-induced release of secondary granules associated with only NIST urban PM. Enzyme Immunosorbent Assays detected increased histamine release from basophils treated with NIST urban PM, a locally collected PM, and the soluble and insoluble components of these particles. NIST urban PM was found to be a potent inducer of histamine release in 4 out of 6 individuals tested. Fractionation studies revealed that soluble (aqueous) and insoluble fractions of NIST urban PM contain histamine-releasing activity. This was also demonstrated for the New Jersey PM10 sample for which the soluble fraction exhibited the most activity. Complementary studies with inhibitors of IgE-mediated histamine release conducted on one test subject suggest that PM-induced histamine release was partially mediated by IgE. A new hypothesis has been formed, suggesting that particle toxicity is related to PM-induced histamine release. Due to the bioactive nature of histamine and its association with many cardiopulmonary responses, the PM- mediated release of histamine should be investigated

  15. 76 FR 78889 - Alternative Personnel Management System (APMS) at the National Institute of Standards and Technology

    Science.gov (United States)

    2011-12-20

    ... more competitive for talent; NIST retained more top performers than a comparison group; and NIST... title 5, United States Code, provides agencies with the authority to appoint candidates directly to jobs...-19-11; 8:45 am] BILLING CODE 3510-13-P ...

  16. 76 FR 62373 - Notice of Public Meeting-Cloud Computing Forum & Workshop IV

    Science.gov (United States)

    2011-10-07

    ...--Cloud Computing Forum & Workshop IV AGENCY: National Institute of Standards and Technology (NIST), Commerce. ACTION: Notice. SUMMARY: NIST announces the Cloud Computing Forum & Workshop IV to be held on... to help develop open standards in interoperability, portability and security in cloud computing. This...

  17. Microfabricated Atomic Clocks at NIST

    Science.gov (United States)

    2004-12-01

    J. A. Kusters and C. A. Adams, 1999, “Performance requirements of communication base station time standards,” RF Design, 22, pp. 28-38. R. Lutwak ...QUESTIONS AND ANSWERS ROBERT LUTWAK (Symmetricom

  18. Analytical quality assurance procedures developed for the IAEA's Reference Asian Man Project (Phase 2)

    International Nuclear Information System (INIS)

    Kawamura, H.; Parr, R.M.; Dang, H.S.; Tian, W.; Barnes, R.M.; Iyengar, G.V.

    2000-01-01

    Analytical quality assurance procedures adopted for use in the IAEA Co-ordinated Research Project on Ingestion and Organ Content of Trace Elements of Importance in Radiological Protection are designed to ensure comparability of the analytical results for Cs, I, Sr, Th, U and other elements in human tissues and diets collected and analysed in nine participating countries. The main analytical techniques are NAA and ICP-MS. For sample preparation, all participants are using identical food blenders which have been centrally supplied after testing for contamination. For quality control of the analyses, six NIST SRMs covering a range of matrices with certified and reference values for the elements of interest have been distributed. A new Japanese reference diet material has also been developed. These quality assurance procedures are summarized here and new data are presented for Cs, I, Sr, Th and U in the NIST SRMs. (author)

  19. Certified reference materials for the determination of uranium, thorium, and plutonium

    International Nuclear Information System (INIS)

    Santoliquido, P.M.

    1990-01-01

    The New Brunswick Laboratory (NBL) is the Department of Energy's Nuclear Materials Measurements and Standards Laboratory. As part of its mission, NBL provides certified reference materials (CRMs) for the analysis of various types of materials encountered in the nuclear fuel cycle. The reference material program at NBL gained greater prominence in 1981, when an interagency agreement between NBL and NBS established NBL as the distributor of one category of SRMs, the special nuclear materials SRMs. When NBS reorganized and became NIST in 1987, NBL bought out the remaining inventory of these particular SRMs which it was already distributing and renamed them as CRMs. The difference between the radioactivity SRMs which NIST still provides and the nuclear material CRMs which NBL provides will be explained. NBL CRMs are distributed worldwide and are used in nuclear safeguards applications and in geological and environmental research. The current NBL CRM inventory will be described

  20. Modeling and Experimental Analysis of Piezoelectric Shakers for High-Frequency Calibration of Accelerometers

    International Nuclear Information System (INIS)

    Vogl, Gregory W.; Harper, Kari K.; Payne, Bev

    2010-01-01

    Piezoelectric shakers have been developed and used at the National Institute of Standards and Technology (NIST) for decades for high-frequency calibration of accelerometers. Recently, NIST researchers built new piezoelectric shakers in the hopes of reducing the uncertainties in the calibrations of accelerometers while extending the calibration frequency range beyond 20 kHz. The ability to build and measure piezoelectric shakers invites modeling of these systems in order to improve their design for increased performance, which includes a sinusoidal motion with lower distortion, lower cross-axial motion, and an increased frequency range. In this paper, we present a model of piezoelectric shakers and match it to experimental data. The equations of motion for all masses are solved along with the coupled state equations for the piezoelectric actuator. Finally, additional electrical elements like inductors, capacitors, and resistors are added to the piezoelectric actuator for matching of experimental and theoretical frequency responses.

  1. Mobile Robot and Mobile Manipulator Research Towards ASTM Standards Development.

    Science.gov (United States)

    Bostelman, Roger; Hong, Tsai; Legowik, Steven

    2016-01-01

    Performance standards for industrial mobile robots and mobile manipulators (robot arms onboard mobile robots) have only recently begun development. Low cost and standardized measurement techniques are needed to characterize system performance, compare different systems, and to determine if recalibration is required. This paper discusses work at the National Institute of Standards and Technology (NIST) and within the ASTM Committee F45 on Driverless Automatic Guided Industrial Vehicles. This includes standards for both terminology, F45.91, and for navigation performance test methods, F45.02. The paper defines terms that are being considered. Additionally, the paper describes navigation test methods that are near ballot and docking test methods being designed for consideration within F45.02. This includes the use of low cost artifacts that can provide alternatives to using relatively expensive measurement systems.

  2. 77 FR 26509 - Notice of Public Meeting-Cloud Computing Forum & Workshop V

    Science.gov (United States)

    2012-05-04

    ...--Cloud Computing Forum & Workshop V AGENCY: National Institute of Standards & Technology (NIST), Commerce. ACTION: Notice. SUMMARY: NIST announces the Cloud Computing Forum & Workshop V to be held on Tuesday... workshop. This workshop will provide information on the U.S. Government (USG) Cloud Computing Technology...

  3. Standardized and Repeatable Technology Evaluation for Cybersecurity Acquisition

    Science.gov (United States)

    2017-02-01

    financial benefit for adopting a cybersecurity technology. 2.2 TECHNOLOGY SELECTION Often organizations will adopt frameworks (e.g., NIST, ISO - 27000 , or...security managers. Many organizations use the NIST1, ISO -270002, or COBIT frameworks3, but for smaller organizations, these frameworks can be overly

  4. The first collision for full SHA-1

    NARCIS (Netherlands)

    M.M.J. Stevens (Marc); E. Bursztein (Elie); P. Karpman (Pierre); A. Albertini (Ange); Y. Markov (Yarik)

    2017-01-01

    textabstractSHA-1 is a widely used 1995 NIST cryptographic hash function standard that was officially deprecated by NIST in 2011 due to fundamental security weaknesses demonstrated in various analyses and theoretical attacks. Despite its deprecation, SHA-1 remains widely used in 2017 for document

  5. 77 FR 22362 - Exemption Requests for Special Nuclear Material License SNM-362, Department of Commerce...

    Science.gov (United States)

    2012-04-13

    ... Nuclear Material License SNM-362, Department of Commerce, Gaithersburg, MD AGENCY: Nuclear Regulatory... Commerce, National Institutes of Standards and Technology (NIST) in Gaithersburg, Maryland. NIST requested... within the Department of Commerce. The SNM license was renewed in 1979, 1985, 1991, and 1997. The current...

  6. Quality assurance programs at the PNL calibrations laboratory

    International Nuclear Information System (INIS)

    Piper, R.K.; McDonald, J.C.; Fox, R.A.; Eichner, F.N.

    1993-03-01

    The calibrations laboratory at Pacific Northwest Laboratory (PNL) serves as a radiological standardization facility for personnel and environmental dosimetry and radiological survey instruments. As part of this function, the calibrations laboratory must maintain radiological reference fields with calibrations traceable to the National Institute of Standards and Technology (NIST). This task is accomplished by a combination of (1) sources or reference instruments calibrated at or by NIST, (2) measurement quality assurance (MQA) interactions with NIST, and (3) rigorous internal annual and quarterly calibration verifications. This paper describes a representative sample of the facilities, sources, and actions used to maintain accurate and traceable fields

  7. 76 FR 35866 - Sunshine Act Meeting Notice

    Science.gov (United States)

    2011-06-20

    ... SUPPLEMENTARY INFORMATION section of this notice. FOR FURTHER INFORMATION CONTACT: Nelson Hastings, NIST Voting... issues. The full meeting agenda will be posted in advance at http://vote.nist.gov . All sessions of this... disability accommodation, such as the need for Sign Language Interpretation, please contact Nelson Hastings...

  8. 76 FR 58730 - Version 4 Critical Infrastructure Protection Reliability Standards

    Science.gov (United States)

    2011-09-22

    ... Critical Cyber Assets; (3) internal, management, approval of the risk-based assessment; (4) external review... consider applicable features of the NIST Risk Management Framework to ensure protection of all cyber... activities in the Risk Management Framework has an associated NIST security standard and/or guidance document...

  9. 75 FR 44216 - Cybersecurity, Innovation and the Internet Economy

    Science.gov (United States)

    2010-07-28

    ... which one cannot measure. Losses related to Internet fraud (e.g., payment fraud, identity theft, credit... Gary Locke Announces NIST to Lead National Initiative for Cybersecurity Education, (April 29, 2010), http://www.commerce.gov/news/press-releases/2010/04/29/commerce-secretary-gary-locke-announces-nist...

  10. Side channel analysis of some hash based MACs: A response to SHA-3 requirements

    DEFF Research Database (Denmark)

    Gauravaram, Praveen; Okeya, Katsuyuki

    2008-01-01

    The forthcoming NIST's Advanced Hash Standard (AHS) competition to select SHA-3 hash function requires that each candidate hash function submission must have at least one construction to support FIPS 198 HMAC application. As part of its evaluation, NIST is aiming to select either a candidate hash...

  11. Ultra-trace determination of iodine in sediments and biological material using UV photochemical generation-inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Grinberg, Patricia [Institute for National Measurements Standards, National Research Council Canada, Ottawa, Ontario, K1A 0R6 (Canada)], E-mail: patricia.grinberg@nrc.ca; Sturgeon, Ralph E. [Institute for National Measurements Standards, National Research Council Canada, Ottawa, Ontario, K1A 0R6 (Canada)

    2009-03-15

    Several sample preparation techniques have been evaluated for the determination of iodine using UV-photochemical generation-quadrupole inductively coupled plasma mass spectrometry. Thermal decomposition of samples at 1000 {sup o}C followed by capture of the liberated iodine in dilute acetic acid permitted subsequent UV-photochemical generation of a volatile iodine species that serves to enhance sensitivity 25-fold over conventional solution nebulization, delivering reagent blank detection limits of 8.75 pg g{sup -1127}I and 0.075 pg g{sup -1129}I for solid samples (400 mg test mass). The methodology was validated through determination of total iodine in several Standard Reference Materials, including NIST 1572 Citrus leaves, NIST 1549 Non-fat milk powder, NIST 1566a Oyster tissue and NIST 2709 San Joaquin Soil. Liberation of iodine from samples and its collection as well as photochemical generation were quantitative, permitting calibration to be achieved using standards prepared in dilute acetic acid.

  12. Comparisons of Reflectance Targets at the Above Water Radiometry Workshop on Long Island Sound, August 4 - 6, 2010

    Science.gov (United States)

    Johnson, B.; Fargion, G. S.; Saunders, R. D.; Ondrusek, M. E.

    2012-12-01

    On August 4-5, 2010, members from the satellite remote sensing community participated in a workshop off the coast of Long Island, New York. The participant's objective was to interpret and implement recently published protocols for measuring normalized, water-leaving spectral radiances by above-water in situ radiometry and compare the results. Each research team applied the protocols to the measurement of the water's surface and three reflectance standard targets supplied by NIST - a white and a gray diffuse reflectance target and a blue ground-glass target. The reflectance values of the water's surface and the test targets were derived and analyzed by each team. We report on the workshop detailing the methods for comparison of the participant's results of the test targets. The workshop served as a preparation for the vigorous validation activities that occurred following the launch of the Visible Infrared Imager Radiometer Suite (VIIRS). Above water, in situ, radiometric measurements using uncalibrated radiometers and standard diffuse reflectance targets are one method used by researchers to validate the VIIRS data products. The Joint Polar Satellite System (JPSS) office provided support to NIST for this work (NA12AANEG0230).

  13. Cloud Computing Explained

    Science.gov (United States)

    Metz, Rosalyn

    2010-01-01

    While many talk about the cloud, few actually understand it. Three organizations' definitions come to the forefront when defining the cloud: Gartner, Forrester, and the National Institutes of Standards and Technology (NIST). Although both Gartner and Forrester provide definitions of cloud computing, the NIST definition is concise and uses…

  14. 77 FR 40332 - Request for Nominations for Members To Serve on National Institute of Standards and Technology...

    Science.gov (United States)

    2012-07-09

    ... duties. Selection of ISPAB members will not be limited to individuals who are nominated. Nominations that... to individuals who are nominated. Nominations that are received and meet the requirements will be... policy advisor of NIST is concerned. Each such report shall identify areas of program emphasis for NIST...

  15. 75 FR 77858 - Sunshine Act Notice

    Science.gov (United States)

    2010-12-14

    ... this notice. FOR FURTHER INFORMATION CONTACT: Nelson Hastings, NIST Voting Program, Information... posted in advance at http://vote.nist.gov . All sessions of this meeting will be open to the public. A... for Sign Language Interpretation, please contact Nelson Hastings by c.o.b. Thursday, January 6, 2011...

  16. 76 FR 22674 - Manufacturing Extension Partnership Advisory Board

    Science.gov (United States)

    2011-04-22

    ... 5 p.m. on May 15, 2011. ADDRESSES: The meeting will be held at the Orlando World Center Marriott... Open Meeting. SUMMARY: NIST announces that the Manufacturing Extension Partnership (MEP) Advisory Board, National Institute of Standards and Technology (NIST) will hold an open meeting on Sunday, May 15, 2011...

  17. 77 FR 38770 - Notice of Consortium on “nSoft Consortium”

    Science.gov (United States)

    2012-06-29

    ... Development Agreement (``CRADA'') with NIST. Membership is limited to 40 for-profit institutions and 15 not... by Member to NIST at the time of CRADA execution and annually in August thereafter. For-profit... Thousand ($10,000), payable at the time of CRADA execution. Subsequent membership payments of Twenty...

  18. Short Term Cyber Attacks with Long Term Effects and Degradation of Supply Chain Capability

    Science.gov (United States)

    2016-09-01

    Artificial Intelligence Research Society Conference, 271–275, St. Augustine: Florida. Goetschalckx, Marc. 2011. Supply Chain Engineering. New York: Springer...term risks in a network supply chain to establish the existence of black swan events. 14. SUBJECT TERMS cybersecurity , supply chain risk...Mission, and Information System View (NIST SP 800–39) .....50 6. Cybersecurity Instruction for the DOD (DODI 8500.01) .........51 7. Risk Management

  19. 15 CFR 290.8 - Reviews of centers.

    Science.gov (United States)

    2010-01-01

    ... TRANSFER OF MANUFACTURING TECHNOLOGY § 290.8 Reviews of centers. (a) Overview. Each Center will be reviewed... involved Center, and Federal officials. An official of NIST shall chair the panel. Each Merit Review Panel... Center be provided by the NIST Manufacturing Technology Centers Program after the sixth year of support...

  20. 75 FR 19941 - Manufacturing Extension Partnership Advisory Board

    Science.gov (United States)

    2010-04-16

    ... 4:30 p.m. on May 2, 2010. ADDRESSES: The meeting will be held at Orlando World Center Marriott... open meeting. SUMMARY: NIST announces that the Manufacturing Extension Partnership (MEP) Advisory Board, National Institute of Standards and Technology (NIST) will hold an open meeting on Sunday, May 2, 2010 from...

  1. Fiscal 1998 'Plant Biotechnology in the 21st Century' workshop report; '21 seiki no shokubutsu biotechnology' workshop 1998 nendo seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    The workshop was opened with the opening remarks by Yamada (President of Nara Institute of Science and Technology (NIST)), the overview of plant biotechnology in the 21st century from academia by Shinmyo (Professor of NIST), and the overview of such technology from Ministry of International Trade and Industry by Katao (Chief of Chemical Industry Division). Lectures and discussions of various topics were conducted for 2 days as follows. The effectiveness of a genomic DNA array method for obtaining the genes for switching genes according to daytime, nighttime, drying, salt, high temperature and low temperature for every plant. Current transfer technology of large DNA fragments into plant cell nuclei and chloroplast. Biological evaluation of the physiological functions and complex stress tolerance capacity transformed by transferring complex stress tolerance genes and useful genes for productivity improvement and value addition. Discussion was also held on the importance of a basic research for biotechnology in the 21st century. (NEDO)

  2. Fiscal 1998 'Plant Biotechnology in the 21st Century' workshop report; '21 seiki no shokubutsu biotechnology' workshop 1998 nendo seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    The workshop was opened with the opening remarks by Yamada (President of Nara Institute of Science and Technology (NIST)), the overview of plant biotechnology in the 21st century from academia by Shinmyo (Professor of NIST), and the overview of such technology from Ministry of International Trade and Industry by Katao (Chief of Chemical Industry Division). Lectures and discussions of various topics were conducted for 2 days as follows. The effectiveness of a genomic DNA array method for obtaining the genes for switching genes according to daytime, nighttime, drying, salt, high temperature and low temperature for every plant. Current transfer technology of large DNA fragments into plant cell nuclei and chloroplast. Biological evaluation of the physiological functions and complex stress tolerance capacity transformed by transferring complex stress tolerance genes and useful genes for productivity improvement and value addition. Discussion was also held on the importance of a basic research for biotechnology in the 21st century. (NEDO)

  3. 77 FR 74829 - Notice of Public Meeting-Cloud Computing and Big Data Forum and Workshop

    Science.gov (United States)

    2012-12-18

    ...--Cloud Computing and Big Data Forum and Workshop AGENCY: National Institute of Standards and Technology... Standards and Technology (NIST) announces a Cloud Computing and Big Data Forum and Workshop to be held on... followed by a one-day hands-on workshop. The NIST Cloud Computing and Big Data Forum and Workshop will...

  4. Atomic and Molecular Data activities at NDC/JAERI

    International Nuclear Information System (INIS)

    Shirai, Toshizo

    2000-01-01

    The NDC/JAERI is a member of the international atomic and molecular (A+M) data center network for fusion, coordinated by the International Atomic Energy Agency. In this poster we introduce our Evaluated Atomic and Molecular Data Library (JEAMDL) developed in collaboration with the JAERI Research Committee on A+M Data and with researchers of ORNL and NIST under the US-Japan fusion cooperation program. JEAMDL comprises databases of collision cross section data and of spectroscopic data. We briefly summarize these two databases below. (author)

  5. Determination of trace elements in some fruits collected in Vietnam and Korea by neutron activation analysis on Dalat and HANARO research reactors

    International Nuclear Information System (INIS)

    Nguyen Thi Sy; Ho Manh Dung; Ho Van Doanh; Tran Quang Thien; Chung Yong-Sam

    2015-01-01

    The k_0-based neutron activation analysis (k_0-NAA) has been applied for determination of trace multi-element in 5 fruits: orange, tomato, persimmon, pear and apple. The samples were collected in Vietnam and Korea, and dried-frozen in laboratory at a temperature of -65"oC, weighed approximately 50 mg or 100 mg each sample, and put in clean polyethylene bags for short and long time irradiations, respectively. The NIST-1547 (Peach Leaves) and IAEA-V-10 (Hay Powder) were used for the purpose of quality control. Both analytical and standard samples were irradiated in the 500 kW Dalat research reactor (Vietnam) and the 20 MW HANARO research reactor (Korea). Concentration of 16 elements: Al, As, Au, Br, Ca, Cl, Co, Eu, Fe, K, La, Mg, Mn, Na, Rb and Zn were determined. By comparison the concentrations of trace elements in the investigated Vietnam and Korea fruits, revealed that they are mostly similar between two places. However, the Ca concentration in orange from Vietnam was approximately 2.5 times higher than that one from Korea, whereas the Ca concentration in pear from Vietnam was approximately 21 times lower than that one from Korea. The Mn concentrations in all of fruits that collected in Vietnam were mostly higher than those collected in Korea, ranging between 1.4 to 2.2 times. (author)

  6. From Fundamental Understanding To Predicting New Nanomaterials For High Capacity Hydrogen/Methane Storage and Carbon Capture

    Energy Technology Data Exchange (ETDEWEB)

    Yildirim, Taner [Univ. of Pennsylvania, Philadelphia, PA (United States)

    2015-03-03

    defined and ordered pores. Here the main challenge is to find a chemically stable MOF required for regeneration of the AB-spent fuel. Finally, for carbon capture application of MOFs, we investigate the performance of a number of metal–organic frameworks with particular focus on their behavior at the low pressures commonly used in swing adsorption. This comparison clearly shows that it is the process that determines which MOF is optimal rather than there being one best MOF, though MOFs that possess enhanced binding at open metal sites generally perform better than those with high surface area. References: 1. Y. Peng, V. Krungleviciute, J. T. Hupp, O. K. Farha, and T. Yildirim, J. Am. Chem. Soc. 135, 11887 (2013). 2. G. Srinivas, V. Krungleviciute, Z. Guo, and T. Yildirim, Ener. Environ. Sci. 7, 335 (2014). 3. G. Burres, and T. Yildirim, Ener. Environ. Sci. 5, 6453 (2012). 4. G. Srinivas, W. Travis, J. Ford, H. Wu, Z. X. Guo, and T. Yildirim, J. Mat. Chem.1, 4167 (2013). 5. For details, please see http://www.ncnr.nist.gov/staff/taner

  7. Technical Cybersecurity Controls for Nuclear Facilities

    International Nuclear Information System (INIS)

    Oh, Jinseok; Ryou, Jaecheol; Kim, Youngmi; Jeong, Choonghei

    2014-01-01

    To strengthen cybersecurity for nuclear facilities, many countries take a regulatory approach. For example, US Government issued several regulations . Title 10, of the Code of Federal Regulations, Section 73.54, 'Protection of Digital Computer and Communication Systems and Networks (10 CFR 73.54) for cybersecurity requirements and Regulatory Guide 5.71 (RG. 5.71) for cybersecurity guidance and so on. In the case of Korea, Korean Government issued '8.22 Cybersecurity of I and C systems (KINS/RG-NO8.22). In particular, Reg. 5.71 provides a list of security controls to address the potential cyber risks to a nuclear facilities. Implementing and adopting security controls, we can improve the level of cybersecurity for nuclear facilities. RG 5.71 follows the recommendation of NIST SP 800-53. NIST standard provides security controls for IT systems. And NRC staff tailored the controls in NIST standards to unique environments of nuclear facilities. In this paper, we are going to analysis and compare NRC RG 5.71 and NIST SP800-53, in particular, for technical security controls. If RG 5.71 omits the specific security control that is included in SP800-53, we would review that omitting is adequate or not. If RG 5.71 includes the specific security control that is not included in SP800-53, we would also review the rationale. And we are going to some security controls to strengthen cybersecurity of nuclear facilities. In this paper, we compared and analyzed of two regulation in technical security controls. RG 5.71 that is based on NIST standard provides well-understood security controls for nuclear facility. But some omitting from NIST standard can threaten security state of nuclear facility

  8. Technical Cybersecurity Controls for Nuclear Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Jinseok; Ryou, Jaecheol [Chungnam National Univ., Daejeon (Korea, Republic of); Kim, Youngmi; Jeong, Choonghei [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2014-05-15

    To strengthen cybersecurity for nuclear facilities, many countries take a regulatory approach. For example, US Government issued several regulations . Title 10, of the Code of Federal Regulations, Section 73.54, 'Protection of Digital Computer and Communication Systems and Networks (10 CFR 73.54) for cybersecurity requirements and Regulatory Guide 5.71 (RG. 5.71) for cybersecurity guidance and so on. In the case of Korea, Korean Government issued '8.22 Cybersecurity of I and C systems (KINS/RG-NO8.22). In particular, Reg. 5.71 provides a list of security controls to address the potential cyber risks to a nuclear facilities. Implementing and adopting security controls, we can improve the level of cybersecurity for nuclear facilities. RG 5.71 follows the recommendation of NIST SP 800-53. NIST standard provides security controls for IT systems. And NRC staff tailored the controls in NIST standards to unique environments of nuclear facilities. In this paper, we are going to analysis and compare NRC RG 5.71 and NIST SP800-53, in particular, for technical security controls. If RG 5.71 omits the specific security control that is included in SP800-53, we would review that omitting is adequate or not. If RG 5.71 includes the specific security control that is not included in SP800-53, we would also review the rationale. And we are going to some security controls to strengthen cybersecurity of nuclear facilities. In this paper, we compared and analyzed of two regulation in technical security controls. RG 5.71 that is based on NIST standard provides well-understood security controls for nuclear facility. But some omitting from NIST standard can threaten security state of nuclear facility.

  9. Methods for quantitative infrared directional-hemispherical and diffuse reflectance measurements using an FTIR and a commercial integrating sphere

    Energy Technology Data Exchange (ETDEWEB)

    Blake, Thomas A.; Johnson, Timothy J.; Tonkyn, Russell G.; Forland, Brenda M.; Myers, Tanya L.; Brauer, Carolyn S.; Su, Yin-Fong; Bernacki, Bruce E.; Hanssen, Leonard; Gonzalez, Gerardo

    2018-01-01

    Infrared integrating sphere measurements of solid samples are important in providing reference data for contact, standoff and remote sensing applications. At the Pacific Northwest National Laboratory (PNNL) we have developed protocols to measure both the directional-hemispherical ( and diffuse (d) reflectances of powders, liquids, and disks of powders and solid materials using a commercially available, matte gold-coated integrating sphere and Fourier transform infrared spectrometer. Detailed descriptions of the sphere alignment and its use for making these reflectance measurements are given. Diffuse reflectance values were found to be dependent on the bidirectional reflection distribution function (BRDF) of the sample and the solid angle intercepted by the sphere’s specular exclusion port. To determine how well the sphere and protocols produce quantitative reflectance data, measurements were made of three diffuse and two specular standards prepared by the National institute of Standards and Technology (NIST, USA), LabSphere Infragold and Spectralon standards, hand-loaded sulfur and talc powder samples, and water. The five NIST standards behaved as expected: the three diffuse standards had a high degree of “diffuseness,” d/ = D > 0.9, whereas the two specular standards had D ≤ 0.03. The average absolute differences between the NIST and PNNL measurements of the NIST standards for both directional-hemispherical and diffuse reflectances are on the order of 0.01 reflectance units. Other quantitative differences between the PNNL-measured and calibration (where available) or literature reflectance values for these standards and materials are given and the possible origins of discrepancies are discussed. Random uncertainties and estimates of systematic uncertainties are presented. Corrections necessary to provide better agreement between the PNNL reflectance values as measured for the NIST standards and the NIST reflectance values for these same standards are also

  10. Cadmium isotope fractionation of materials derived from various industrial processes

    Energy Technology Data Exchange (ETDEWEB)

    Martinková, Eva, E-mail: eva.cadkova@geology.cz [Czech Geological Survey, Geologická 6, 152 00 Prague 5 (Czech Republic); Chrastný, Vladislav, E-mail: chrastny@fzp.czu.cz [Faculty of Environmental Sciences, Czech University of Life Sciences Prague, Kamýcká 129, 165 21 Prague 6 (Czech Republic); Francová, Michaela, E-mail: michaela.francova@fzp.czu.cz [Faculty of Environmental Sciences, Czech University of Life Sciences Prague, Kamýcká 129, 165 21 Prague 6 (Czech Republic); Šípková, Adéla, E-mail: adela.sipkova@geology.cz [Czech Geological Survey, Geologická 6, 152 00 Prague 5 (Czech Republic); Čuřík, Jan, E-mail: jan.curik@geology.cz [Czech Geological Survey, Geologická 6, 152 00 Prague 5 (Czech Republic); Myška, Oldřich, E-mail: oldrich.myska@geology.cz [Czech Geological Survey, Geologická 6, 152 00 Prague 5 (Czech Republic); Mižič, Lukáš, E-mail: lukas.mizic@geology.cz [Czech Geological Survey, Geologická 6, 152 00 Prague 5 (Czech Republic)

    2016-01-25

    Highlights: • All studied industrial processes were accompanied by Cd isotope fractionation. • ϵ{sup 114/110} Cd values of the waste materials were discernible from primary sources. • Technology in use plays an important role in Cd isotope fractionation. - Abstract: Our study represents ϵ{sup 114/110} Cd {sub NIST3108} values of materials resulting from anthropogenic activities such as coal burning, smelting, refining, metal coating, and the glass industry. Additionally, primary sources (ore samples, pigment, coal) processed in the industrial premises were studied. Two sphalerites, galena, coal and pigment samples exhibited ϵ{sup 114/110} Cd{sub NIST3108} values of 1.0 ± 0.2, 0.2 ± 0.2, 1.3 ± 0.1, −2.3 ± 0.2 and −0.1 ± 0.3, respectively. In general, all studied industrial processes were accompanied by Cd isotope fractionation. Most of the industrial materials studied were clearly distinguishable from the samples used as a primary source based on ϵ{sup 114/110} Cd {sub NIST3108} values. The heaviest ϵ{sup 114/110} Cd{sub NIST3108} value of 58.6 ± 0.9 was found for slag resulting from coal combustion, and the lightest ϵ{sup 114/110} Cd{sub NIST3108} value of −23 ± 2.5 was observed for waste material after Pb refinement. It is evident that ϵ{sup 114/110} Cd {sub NIST3108} values depend on technological processes, and in case of incomplete Cd transfer from source to final waste material, every industrial activity creates differences in Cd isotope composition. Our results show that Cd isotope analysis is a promising tool to track the origins of industrial waste products.

  11. Long-term temporal stability of the National Institute of Standards and Technology spectral irradiance scale determined with absolute filter radiometers

    International Nuclear Information System (INIS)

    Yoon, Howard W.; Gibson, Charles E.

    2002-01-01

    The temporal stability of the National Institute of Standards and Technology (NIST) spectral irradiance scale as measured with broadband filter radiometers calibrated for absolute spectral irradiance responsivity is described. The working standard free-electron laser (FEL) lamps and the check standard FEL lamps have been monitored with radiometers in the ultraviolet and the visible wavelength regions. The measurements made with these two radiometers reveal that the NIST spectral irradiance scale as compared with an absolute thermodynamic scale has not changed by more than 1.5% in the visible from 1993 to 1999. Similar measurements in the ultraviolet reveal that the corresponding change is less than 1.5% from 1995 to 1999. Furthermore, a check of the spectral irradiance scale by six different filter radiometers calibrated for absolute spectral irradiance responsivity based on the high-accuracy cryogenic radiometer shows that the agreement between the present scale and the detector-based scale is better than 1.3% throughout the visible to the near-infrared wavelength region. These results validate the assigned spectral irradiance of the widely disseminated NIST or NIST-traceable standard sources

  12. The multiple disk chopper neutron time-of-flight spectrometer at NIST

    International Nuclear Information System (INIS)

    Altorfer, F.B.; Cook, J.C.; Copley, J.R.D.

    1995-01-01

    A highly versatile multiple disk chopper neutron time-of-flight spectrometer is being installed at the Cold Neutron Research Facility of the National institute of Standards and Technology. This new instrument will fill an important gap in the portfolio of neutron inelastic scattering spectrometers in North America. It will be used for a wide variety of experiments such as studies of magnetic and vibrational excitations, tunneling spectroscopy, and quasielastic neutron scattering investigations of local and translational diffusion. The instrument uses disk choppers to monochromate and pulse the incident beam, and the energy changes of scattered neutrons are determined from their times-of-flight to a large array of detectors. The disks and the guide have been designed to make the instrument readily adaptable to the specific performance requirements of experimenters. The authors present important aspects of the design, as well as estimated values of the flux at the sample and the energy resolution for elastic scattering. The instrument should be operational in 1996

  13. BILATERAL KEY COMPARISON SIM.T-K6.5 ON HUMIDITY STANDARDS IN THE DEW/FROST-POINT TEMPERATURE RANGE FROM −30 °C TO +20 °C

    Science.gov (United States)

    Meyer, C.W.; Solano, A.

    2016-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures over the range −30 °C TO +20 °C was carried out by the National Institute of Standards and Technology (NIST, USA) and the Laboratorio Costarricense de Metrología (LACOMET, Costa Rica), between February 2015 and August 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and LACOMET and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining the degree of equivalence between the dew/frost-point standards of NIST and LACOMET. PMID:28066029

  14. Activity measurements of {sup 55}Fe by two different methods

    Energy Technology Data Exchange (ETDEWEB)

    Cruz, P.A.L. da; Iwahara, A.; Silva, C.J. da; Poledna, R.; Loureiro, J.S.; Silva, M.A.L. da, E-mail: palcruz@ird.gov.br [Instituto de Radioproteção e Dosimetria (LNMRI/IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. Nacional de Metrologia das Radiações Ionizantes; Ruzzarin, Anelise [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (PEN/COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear

    2017-07-01

    A calibrated germanium detector and CIEMAT/NIST liquid scintillation method were used in the standardization of solution of {sup 55}Fe coming from a key-comparison BIPM. Commercial HISAFE'3 cocktails were used in source preparation for activity measurements in CIEMAT/NIST method. Measurements were performed in Liquid Scintillation Counter. In the germanium counting method standard point sources were prepared for obtaining atomic number versus efficiency curve of the detector in order to obtain the efficiency of 5.9 keV KX-ray of {sup 55}Fe by interpolation. The activity concentrations obtained were 508.2 ± 3.56 and 510.0 ± 16.20 kBq/g, respectively for CIEMAT/NIST and germanium methods. (author)

  15. BILATERAL KEY COMPARISON SIM.T-K6.5 ON HUMIDITY STANDARDS IN THE DEW/FROST-POINT TEMPERATURE RANGE FROM -30 °C TO +20 °C.

    Science.gov (United States)

    Meyer, C W; Solano, A

    2016-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures over the range -30 °C TO +20 °C was carried out by the National Institute of Standards and Technology (NIST, USA) and the Laboratorio Costarricense de Metrología (LACOMET, Costa Rica), between February 2015 and August 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and LACOMET and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining the degree of equivalence between the dew/frost-point standards of NIST and LACOMET.

  16. Uncertainty Analysis of Spectral Irradiance Reference Standards Used for NREL Calibrations

    Energy Technology Data Exchange (ETDEWEB)

    Habte, A.; Andreas, A.; Reda, I.; Campanelli, M.; Stoffel, T.

    2013-05-01

    Spectral irradiance produced by lamp standards such as the National Institute of Standards and Technology (NIST) FEL-type tungsten halogen lamps are used to calibrate spectroradiometers at the National Renewable Energy Laboratory. Spectroradiometers are often used to characterize spectral irradiance of solar simulators, which in turn are used to characterize photovoltaic device performance, e.g., power output and spectral response. Therefore, quantifying the calibration uncertainty of spectroradiometers is critical to understanding photovoltaic system performance. In this study, we attempted to reproduce the NIST-reported input variables, including the calibration uncertainty in spectral irradiance for a standard NIST lamp, and quantify uncertainty for measurement setup at the Optical Metrology Laboratory at the National Renewable Energy Laboratory.

  17. 76 FR 70412 - Smart Grid Advisory Committee

    Science.gov (United States)

    2011-11-14

    ... recommendations that the Committee will consider at the meeting will be posted on the SGAC Web site at http://www... posted on the Smart Grid Web site at http://www.nist.gov/smartgrid . DATES: The SGAC will hold a meeting... (5 U.S.C. App.). Background information on the Committee is available at http://www.nist.gov...

  18. Allele frequency distribution for 21 autosomal STR loci in Nepal.

    Science.gov (United States)

    Kraaijenbrink, T; van Driem, G L; Opgenort, J R M L; Tuladhar, N M; de Knijff, P

    2007-05-24

    The allele frequency distributions of 21 autosomal loci contained in the AmpFlSTR Identifiler, the Powerplex 16 and the FFFL multiplex PCR kits, was studied in 953 unrelated individuals from Nepal. Several new alleles (i.e. not yet reported in the NIST Short Tandem Repeat DNA Internet DataBase [http://www.cstl.nist.gov/biotech/strbase/]) have been detected in the process.

  19. Determination of trace elements in standard reference materials by the ko-standardization method

    International Nuclear Information System (INIS)

    Smodis, B.; Jacimovic, R.; Stegnar, P.; Jovanovic, S.

    1990-01-01

    The k o -standardization method is suitable for routine multielement determinations by reactor neutron activation analysis (NAA). Investigation of NIST standard reference materials SRM 1571 Orchard Leaves, SRM 1572 Citrus leaves, and SRM 1573 Tomato Leaves showed the systematic error of 12 certified elements determined to be less than 8%. Thirty-four elements were determined in NIST proposed SRM 1515 Apple Leaves

  20. Preliminary Results of BTDF Calibration of Transmissive Solar Diffusers for Remote Sensing

    Science.gov (United States)

    Georgiev, Georgi T.; Butler, James J.; Thome, Kurt; Cooksey, Catherine; Ding, Leibo

    2016-01-01

    Satellite instruments operating in the reflected solar wavelength region require accurate and precise determination of the optical properties of their diffusers used in pre-flight and post-flight calibrations. The majority of recent and current space instruments use reflective diffusers. As a result, numerous Bidirectional Reflectance Distribution Function (BRDF) calibration comparisons have been conducted between the National Institute of Standards and Technology (NIST) and other industry and university-based metrology laboratories. However, based on literature searches and communications with NIST and other laboratories, no Bidirectional Transmittance Distribution Function (BTDF) measurement comparisons have been conducted between National Measurement Laboratories (NMLs) and other metrology laboratories. On the other hand, there is a growing interest in the use of transmissive diffusers in the calibration of satellite, air-borne, and ground-based remote sensing instruments. Current remote sensing instruments employing transmissive diffusers include the Ozone Mapping and Profiler Suite instrument (OMPS) Limb instrument on the Suomi-National Polar-orbiting Partnership (S-NPP) platform,, the Geostationary Ocean Color Imager (GOCI) on the Korea Aerospace Research Institute's (KARI) Communication, Ocean, and Meteorological Satellite (COMS), the Ozone Monitoring Instrument (OMI) on NASA's Earth Observing System (EOS) Aura platform, the Tropospheric Emissions: Monitoring of Pollution (TEMPO) instrument and the Geostationary Environmental Monitoring Spectrometer (GEMS).. This ensemble of instruments requires validated BTDF measurements of their on-board transmissive diffusers from the ultraviolet through the near infrared. This paper presents the preliminary results of a BTDF comparison between the NASA Diffuser Calibration Laboratory (DCL) and NIST on quartz and thin Spectralon samples.

  1. Preliminary results of BTDF calibration of transmissive solar diffusers for remote sensing

    Science.gov (United States)

    Georgiev, Georgi T.; Butler, James J.; Thome, Kurt; Cooksey, Catherine; Ding, Leibo

    2016-09-01

    Satellite instruments operating in the reflected solar wavelength region require accurate and precise determination of the optical properties of their diffusers used in pre-flight and post-flight calibrations. The majority of recent and current space instruments use reflective diffusers. As a result, numerous Bidirectional Reflectance Distribution Function (BRDF) calibration comparisons have been conducted between the National Institute of Standards and Technology (NIST) and other industry and university-based metrology laboratories. However, based on literature searches and communications with NIST and other laboratories, no Bidirectional Transmittance Distribution Function (BTDF) measurement comparisons have been conducted between National Measurement Laboratories (NMLs) and other metrology laboratories. On the other hand, there is a growing interest in the use of transmissive diffusers in the calibration of satellite, air-borne, and ground-based remote sensing instruments. Current remote sensing instruments employing transmissive diffusers include the Ozone Mapping and Profiler Suite instrument (OMPS) Limb instrument on the Suomi-National Polar-orbiting Partnership (S-NPP) platform,, the Geostationary Ocean Color Imager (GOCI) on the Korea Aerospace Research Institute's (KARI) Communication, Ocean, and Meteorological Satellite (COMS), the Ozone Monitoring Instrument (OMI) on NASA's Earth Observing System (EOS) Aura platform, the Tropospheric Emissions: Monitoring of Pollution (TEMPO) instrument and the Geostationary Environmental Monitoring Spectrometer (GEMS).. This ensemble of instruments requires validated BTDF measurements of their onboard transmissive diffusers from the ultraviolet through the near infrared. This paper presents the preliminary results of a BTDF comparison between the NASA Diffuser Calibration Laboratory (DCL) and NIST on quartz and thin Spectralon samples.

  2. Measuring hydrogen by cold-neutron prompt-gamma activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Lindstrom, R M; Paul, R L; Greenberg, R R [National Inst. of Standards and Technology, Gaithersburg, MD (United States). Div. of Inorganic Analytical Research; Vincent, D H [Michigan Univ., Ann Arbor, MI (United States). Dept. of Nuclear Engineering

    1994-05-01

    By irradiating with cold neutrons and avoiding hydrogenous materials of construction, a PGAA instrument was developed at the Cold Neutron Research Facility at NIST with hydrogen detection limits in the microgram range in many materials. Quantities of 5-10 [mu]g H/g are presently measurable in gram-sized samples of silicon or quartz, and of order 0.01 wt % can be quantitatively measured in complex silicate rocks. (author) 19 refs.; 1 fig.; 1 tab.

  3. Cybersecurity Cost of Quality: Managing the Costs of Cybersecurity Risk Management

    OpenAIRE

    Radziwill, Nicole M.; Benton, Morgan C.

    2017-01-01

    There is no standard yet for measuring and controlling the costs associated with implementing cybersecurity programs. To advance research and practice towards this end, we develop a mapping using the well-known concept of quality costs and the Framework Core within the Cybersecurity Framework produced by the National Institute of Standards and Technology (NIST) in response to the Cybersecurity Enhancement Act of 2014. This mapping can be easily adopted by organizations that are already using ...

  4. Efficiency of methods for Karl Fischer determination of water in oils based on oven evaporation and azeotropic distillation.

    Science.gov (United States)

    Larsson, William; Jalbert, Jocelyn; Gilbert, Roland; Cedergren, Anders

    2003-03-15

    The efficiency of azeotropic distillation and oven evaporation techniques for trace determination of water in oils has recently been questioned by the National Institute of Standards and Technology (NIST), on the basis of measurements of the residual water found after the extraction step. The results were obtained by volumetric Karl Fischer (KF) titration in a medium containing a large excess of chloroform (> or = 65%), a proposed prerequisite to ensure complete release of water from the oil matrix. In this work, the extent of this residual water was studied by means of a direct zero-current potentiometric technique using a KF medium containing more than 80% chloroform, which is well above the concentration recommended by NIST. A procedure is described that makes it possible to correct the results for dilution errors as well as for chemical interference effects caused by the oil matrix. The corrected values were found to be in the range of 0.6-1.5 ppm, which should be compared with the 12-34 ppm (uncorrected values) reported by NIST for the same oils. From this, it is concluded that the volumetric KF method used by NIST gives results that are much too high.

  5. Detecting Potentially Compromised Credentials in a Large-Scale Production Single-Signon System

    Science.gov (United States)

    2014-06-01

    Online ]. Available: http://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-63-2.pdf. [2] Department of Defense. (2004). Department of Defense...personnel identity program. [ Online ]. Available: http://www.cac.mil/docs/DoDD-1000.25.pdf. xv THIS PAGE INTENTIONALLY LEFT BLANK xvi Acknowledgements...susceptible to security vulnerabilities like any other modern day infrastruc- ture. Criminal enterprises and individual scam artists look to capitalize on

  6. Characterization of inorganic compounds in nutritional supplements by the instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Nardi, Daniela T.; Saiki, Mitiko; Vasconcellos, Maria B.A.

    2000-01-01

    In this work instrumental neutron activation analysis was applied in the analyses of samples of nutritional supplements in order to evaluate the composition of their essential inorganic components. Results obtained in these analyses presented, in general, a good agreement with the label values. Precision and accuracy of the results were also evaluated by analyzing NIST 2704 Buffalo River Sediment and NIST 1400 Bone Ash reference materials. (author)

  7. Report on Pairing-based Cryptography.

    Science.gov (United States)

    Moody, Dustin; Peralta, Rene; Perlner, Ray; Regenscheid, Andrew; Roginsky, Allen; Chen, Lily

    2015-01-01

    This report summarizes study results on pairing-based cryptography. The main purpose of the study is to form NIST's position on standardizing and recommending pairing-based cryptography schemes currently published in research literature and standardized in other standard bodies. The report reviews the mathematical background of pairings. This includes topics such as pairing-friendly elliptic curves and how to compute various pairings. It includes a brief introduction to existing identity-based encryption (IBE) schemes and other cryptographic schemes using pairing technology. The report provides a complete study of the current status of standard activities on pairing-based cryptographic schemes. It explores different application scenarios for pairing-based cryptography schemes. As an important aspect of adopting pairing-based schemes, the report also considers the challenges inherent in validation testing of cryptographic algorithms and modules. Based on the study, the report suggests an approach for including pairing-based cryptography schemes in the NIST cryptographic toolkit. The report also outlines several questions that will require further study if this approach is followed.

  8. Performance Monitoring of Chilled-Water Distribution Systems Using HVAC-Cx.

    Science.gov (United States)

    Ferretti, Natascha Milesi; Galler, Michael A; Bushby, Steven T

    2017-01-01

    In this research we develop, test, and demonstrate the newest extension of the software HVAC-Cx (NIST and CSTB 2014), an automated commissioning tool for detecting common mechanical faults and control errors in chilled-water distribution systems (loops). The commissioning process can improve occupant comfort, ensure the persistence of correct system operation, and reduce energy consumption. Automated tools support the process by decreasing the time and the skill level required to carry out necessary quality assurance measures, and as a result they enable more thorough testing of building heating, ventilating, and air-conditioning (HVAC) systems. This paper describes the algorithm, developed by National Institute of Standards and Technology (NIST), to analyze chilled-water loops and presents the results of a passive monitoring investigation using field data obtained from BACnet ® (ASHRAE 2016) controllers and presents field validation of the findings. The tool was successful in detecting faults in system operation in its first field implementation supporting the investigation phase through performance monitoring. Its findings led to a full energy retrocommissioning of the field site.

  9. With Great Measurements Come Great Results

    Science.gov (United States)

    Williams, Carl

    Measurements are the foundation for science and modern life. Technologies we take for granted every day depend on them-cell phones, CAT scans, pharmaceuticals, even sports equipment. Metrology, or measurement science, determines what industry can make reliably and what they cannot. At the National Institute of Standards and Technology (NIST) we specialize in making world class measurements that an incredibly wide range of industries use to continually improve their products - computer chips with nanoscale components, atomic clocks that you can hold in your hand, lasers for both super-strong welds and delicate eye surgeries. Think of all the key technologies developed over the last 100 years and better measurements, standards, or analysis techniques played a role in making them possible. NIST works collaboratively with industry researchers on the advanced metrology for tomorrow's technologies. A new kilogram based on electromagnetic force, cars that weigh half as much but are just as strong, quantum computers, personalized medicine, single atom devices - it's all happening in our labs now. This talk will focus on how metrology creates the future.

  10. Quantification of ultraviolet photon emission from interaction of charged particles in materials of interest in radiation biology research

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, Syed Bilal, E-mail: ahmadsb@mcmaster.ca [Department of Medical Physics and Applied Radiation Sciences, University of McMaster, Hamilton, ON (Canada); Department of Physics and Applied Mathematics, Pakistan Institute of Engineering and Applied Sciences, Islamabad (Pakistan); McNeill, Fiona E., E-mail: fmcneill@mcmaster.ca [Department of Medical Physics and Applied Radiation Sciences, University of McMaster, Hamilton, ON (Canada); Prestwich, William V., E-mail: prestwic@mcmaster.ca [Department of Medical Physics and Applied Radiation Sciences, University of McMaster, Hamilton, ON (Canada); Byun, Soo Hyun, E-mail: soohyun@mcmaster.ca [Department of Medical Physics and Applied Radiation Sciences, University of McMaster, Hamilton, ON (Canada); Seymour, Colin, E-mail: seymouc@mcmaster.ca [Department of Medical Physics and Applied Radiation Sciences, University of McMaster, Hamilton, ON (Canada); Mothersill, Carmel E., E-mail: mothers@mcmaster.ca [Department of Medical Physics and Applied Radiation Sciences, University of McMaster, Hamilton, ON (Canada)

    2014-01-15

    In radiation biology experiments often cells are irradiated using charged particles with the intention that only a specified number of cells are hit by the primary ion track. However, in doing so several other materials such as the cell container and the growth media etc. are also irradiated, and UV radiation emitted from these materials can potentially interact with the cells. We have hypothesized that some “bystander effects” that are thought to be chemically mediated, may be, in fact, a physical effect, where UV is interacting with non-targeted cells. Based upon our hypothesis we quantified the emission of UV from Polypropylene, Mylar, Teflon, and Cellophane which are all commonly used materials in radiation biology experiments. Additionally we measured the NIST standard materials of Oyster tissue and Citrus leaves as these powdered materials are derived from living cells. Protons accelerated up to an energy of 2.2 MeV, in a 3 MV Van de Graff accelerator, were used for irradiation. Beam current was kept to 10 nA, which corresponds to a proton fluence rate of 2.7 × 10{sup 10} protons mm{sup −2} s{sup −1}. All the materials were found to emit light at UV frequencies and intensities that were significant enough to conduct a further investigation for their biological consequences. Mylar and polypropylene are commonly used in radiation induced bystander effect studies and are considered to be non-fluorescent. However our study showed that this is not the case. Significant luminescence observed from the irradiated NIST standard reference materials for Oyster tissue and Citrus leaves verified that the luminescence emission is not restricted only to the polymeric materials that are used to contain cells. It can also occur from ion interactions within the cells as well.

  11. An automatic micro-sequential injection bead injection lab-on-valve (muSI-BI-LOV) assembly for speciation analysis of ultra trace levels of Cr(III) and Cr(VI) incorporating on-line chemical reduction and employing detection by electrothermal atomic absorption spectrometry (ETAAS)

    DEFF Research Database (Denmark)

    Long, Xiangbao; Miró, Manuel; Hansen, Elo Harald

    2005-01-01

    and determination of trace levels of Cr(III) and Cr(VI) in environmental samples. The method was validated by determination of chromium species in CRM and NIST standard reference materials, and by spike recoveries of surface waters. Statistical comparison of means between experimental results and the total chromium...... certified values for the CRM and NIST materials revealed the non-existence of significant differences at a 95% confidence level....

  12. Department of Defense: Electronic Biometric Transmission Specification. Version 2.0

    Science.gov (United States)

    2009-03-27

    DoD biometric systems. This document contains the technical details of the DoD EBTS. Readers are expected to have working knowledge of the ANSI/NIST...binary level codes. Readers are expected to have working knowledge of the ANSI/NIST-ITL 1-2007 as a prerequisite for understanding this specification...Body = FBODY Abstract Body = ABBODY Roles (Knight, Witch, man, etc.) = ROLES Sports Figures (Football Player, Skier , etc.) = SPORT Male Body Parts

  13. Local area networks in radiation detection systems: advantages and pitfalls

    Energy Technology Data Exchange (ETDEWEB)

    Blaauw, M [Interfaculty Reactor Inst., Delft Univ. of Technology (Netherlands); Lindstrom, R M [Inorganic Analytical Research Div., National Inst. of Standards and Technology, Gaithersburg, MD (United States)

    1993-06-01

    Both at the Interfaculty Reactor Institute (IRI) and at the National Institute of Standards and Technology (NIST), local area networks are being used to acquire and process data from multiple [gamma]-ray spectrometers. The IRI system was only recently set up. A comparison is made between the NIST network, the old IRI network and the new IRI network, resulting in recommendations for new systems to be set up. (orig.)

  14. SERC 2014 2018 Technical Plan: 2016 Update

    Science.gov (United States)

    2016-02-18

    economical design approaches for detecting attacks. This has resulted in the start of prototyping projects for a DoD radar, a 3D printer (NIST), police...Pilot Continuously  Productize 4 Initiated projects with NIST on 3D Printers and Virginia State Police focused on automobiles that have both...integration, and incremental verification and validation. The Agile SE Program seeks balance between the integrity and stability of traditional SE and

  15. Evaluation and compilation of DOE waste package test data

    International Nuclear Information System (INIS)

    Interrante, C.G.; Fraker, A.C.; Escalante, E.

    1993-06-01

    This report summarizes evaluations by the National Institute of Standards and Technology (NIST) of some of the Department of Energy (DOE) activities on waste packages designed for containment of radioactive high-level nuclear waste (HLW) for the six-month period, August 1989--January 1990. This includes reviews of related materials research and plans, information on the Yucca Mountain, Nevada disposal site activities, and other information regarding supporting research and special assistance. Short discussions are given relating to the publications reviewed and complete reviews and evaluations are included. Reports of other work are included in the Appendices

  16. WE-A-17A-01: Absorbed Dose Rate-To-Water at the Surface of a Beta-Emitting Planar Ophthalmic Applicator with a Planar, Windowless Extrapolation Chamber

    Energy Technology Data Exchange (ETDEWEB)

    Riley, A [of Wisconsin Medical Radiation Research Center, Madison, WI (United States); Soares, C [NIST (Retired), Gaithersburg, MD (United States); Micka, J; Culberson, W [University of Wisconsin Medical Radiation Research Center, Madison, WI (United States); DeWerd, L [University of WIMadison/ ADCL, Madison, WI (United States)

    2014-06-15

    Purpose: Currently there is no primary calibration standard for determining the absorbed dose rate-to-water at the surface of β-emitting concave ophthalmic applicators and plaques. Machining tolerances involved in the design of concave window extrapolation chambers are a limiting factor for development of such a standard. Use of a windowless extrapolation chamber avoids these window-machining tolerance issues. As a windowless extrapolation chamber has never been attempted, this work focuses on proof of principle measurements with a planar, windowless extrapolation chamber to verify the accuracy in comparison to initial calibration, which could be extended to the design of a hemispherical, windowless extrapolation chamber. Methods: The window of an extrapolation chamber defines the electrical field, aids in aligning the source parallel to the collector-guard assembly, and decreases the backscatter due to attenuation of lower electron energy. To create a uniform and parallel electric field in this research, the source was made common to the collector-guard assembly. A precise positioning protocol was designed to enhance the parallelism of the source and collector-guard assembly. Additionally, MCNP5 was used to determine a backscatter correction factor to apply to the calibration. With these issues addressed, the absorbed dose rate-to-water of a Tracerlab 90Sr planar ophthalmic applicator was determined using National Institute of Standards and Technology's (NIST) calibration formalism, and the results of five trials with this source were compared to measurements at NIST with a traditional extrapolation chamber. Results: The absorbed dose rate-to-water of the planar applicator was determined to be 0.473 Gy/s ±0.6%. Comparing these results to NIST's determination of 0.474 Gy/s yields a −0.6% difference. Conclusion: The feasibility of a planar, windowless extrapolation chamber has been demonstrated. A similar principle will be applied to developing a

  17. The development and certification of Standard Reference Materials (SRMs) to assess and ensure accurate measurement of Pb in the environment.

    Science.gov (United States)

    Fassett, J D; MacDonald, B S

    2001-08-01

    The National Institute of Standards and Technology (NIST) has had a major quality-assurance role in the federal effort to reduce lead poisoning of children in the United States through its mission of ensuring the accuracy of chemical measurements. NIST certifies reference materials (standard reference materials--SRMs) that are used to benchmark measurements by secondary and field methods of analysis--to ensure that decisions of great health and economic impact are soundly based on good measurement science. Over the past 10 years, in cooperation with the US Environmental Protection Agency (EPA), US Department of Housing and Urban Development (HUD), and the United States Geological Survey (USGS), NIST has prepared and certified SRMs for lead content in soil, indoor dust, and paint. The role of these materials in meeting regulatory and abatement needs is described and their certified values are summarized.

  18. Computational Chemistry Comparison and Benchmark Database

    Science.gov (United States)

    SRD 101 NIST Computational Chemistry Comparison and Benchmark Database (Web, free access)   The NIST Computational Chemistry Comparison and Benchmark Database is a collection of experimental and ab initio thermochemical properties for a selected set of molecules. The goals are to provide a benchmark set of molecules for the evaluation of ab initio computational methods and allow the comparison between different ab initio computational methods for the prediction of thermochemical properties.

  19. Physics with Ultracold and Thermal Neutron Beams

    International Nuclear Information System (INIS)

    None

    2004-01-01

    The final report is broken into 5 segments, reflecting research conclusions reached during specific time periods: 1991-1997, 1997-1999, 1999-2000, 2000-2001, and 2001-2002. The first part of the work reported was carried out at the 2 Mw research reactor of the Rhode Island Nuclaer Science Center (RJNSC). Chosen for study was the slow phase separation in mixtures of oil and water in the presence of a surfactant, and the structural features of an oil layer during the slow build-up from the gas phase. The results of these measurements, as well as studies of the capillary wave properties of oil/surfactant/water interfaces are described. The second part of the work was performed at the neutron reflection facilities of the Intennse Pulsed Neutron Source at Argonne and of the NBSR reactor at NIST. At Argonne, the uniaxial magnetic order of an Fe/CR superlattice was investigated, while the experiments at NIST studied the swelling behavior of ordered thin films of diblock copolymers when they were exposed to solvent vapors. The third part of the work was concerned with the storage properties of ultracold neturons in a trap. New experiments on spectral evolution during storage, using the UCN source of the Institut Laue-Langevin were able to be run. Subsequent periods focussed on the ultracold neutrons work, spin valve multilayer systems, and pseudo-partial wetting

  20. Simulations and measurements of the performance of a channeled neutron guide for a time-of-flight spectrometer at the NIST Center for Neutron Research

    International Nuclear Information System (INIS)

    Cook, Jeremy C.; Copley, John R.D.

    2004-01-01

    We describe the identification and analysis of the principal sources of intensity loss within the five-channeled neutron guide tube that was originally installed in the chopper section of the Disk Chopper Spectrometer at the National Institute of Standards and Technology Center for Neutron Research. (The purpose of the five channels was to optimize intensity and resolution in three different modes of operation known as ''resolution modes.'') By combining measurements, Monte Carlo simulations, and analytical calculations, we have developed a model that successfully explains performance losses in the original guide. We have used this model to quantify expected returns in performance using a replacement guide in which the principal contributions to the intensity loss are reduced to the minimum achievable with current technology. We have also estimated the intensity gains that would be achieved if one of the limited number of options were adopted for modifying the original guide in a manner likely to produce such gains. We describe factors that affect the performance of the original guide and compare the measured and predicted performance of the modified guide against predictions for the optimal replacement guide. The simulations indicate that the modified guide (which has three channels rather than the original five) produces greater intensity gains over a large incident wavelength band for the low and medium resolution modes, whereas a high quality replacement guide greatly improves performance in the high resolution mode of operation. Because the low and medium resolution modes are most heavily demanded, we opted to modify the guide rather than replace it. We describe the nature of this modification and present intensity measurements that meet or exceed predictions in all resolution modes with no detectable change in the energy resolution nor increase in the instrumental background

  1. Application for airborne particulate matter as a demonstration using k0-NAA method in Dalat nuclear research institute of Vietnam

    International Nuclear Information System (INIS)

    Ho Manh Dung; Cao Dong Vu; Nguyen Thi Sy; Truong Y; Nguyen Thanh Binh

    2004-01-01

    The airborne particulate samples have been collected using two types of polycarbonate membrane filter PM 2.5 and PM 2-5-10 in two typical sites of industrial (Ho Chi Minh City) and rural (Dateh) regions in south of Vietnam. The concentration of trace elements in the samples has been determined by the k 0 -NAA procedure developed in Dalat NRI. In order to check the developed k 0 -NAA procedure for the airborne particulate matter, two standard reference materials (SRMs) Urban Particulate NIST-1648 and Vehicle Exhaust Particulates NIES-8 were analyzed and the obtained results have been compared and interpreted in term of deviation between experimental results and the certified values. (author)

  2. Wavelengths, energy levels and hyperfine structure of Mn II and Sc II.

    Science.gov (United States)

    Nave, Gillian; Pickering, Juliet C.; Townley-Smith, Keeley I. M.; Hala, .

    2015-08-01

    For many decades, the Atomic Spectroscopy Groups at the National Institute of Standards and Technology (NIST) and Imperial College London (ICL) have measured atomic data of astronomical interest. Our spectrometers include Fourier transform (FT) spectrometers at NIST and ICL covering the region 1350 Å to 5.5 μm and a 10.7-m grating spectrometer at NIST covering wavelengths from 300 - 5000 Å. Sources for these spectra include high-current continuous and pulsed hollow cathode (HCL) lamps, Penning discharges, and sliding spark discharges. Recent work has focused on the measurement and analysis of wavelengths, energy levels, and hyperfine structure (HFS) constants for iron-group elements. The analysis of FT spectra of Cr I, Mn I, and Mn II is being led by ICL and is described in a companion poster [1]. Current work being led by NIST includes the analysis of HFS in Mn II, analysis of Mn II in the vacuum ultraviolet, and a comprehensive analysis of Sc II.Comprehensive HFS constants for Mn II are needed for the interpretation of stellar spectra and incorrect abundances may be obtained when HFS is omitted. Holt et al. [2] have measured HFS constants for 59 levels of Mn II using laser spectroscopy. We used FT spectra of Mn/Ni and Mn/Cu HCLs covering wavelength ranges from 1350 Å to 5.4 μm to confirm 26 of the A constants of Holt et al. and obtain values for roughly 40 additional levels. We aim to obtain HFS constants for the majority of lines showing significant HFS that are observed in chemically-peculiar stars.Spectra of Sc HCLs have been recorded from 1800 - 6700 Å using a vacuum ultraviolet FT spectrometer at NIST. Additional measurements to cover wavelengths above 6700 Å and below 1800 Å are in progress. The spectra are being analyzed by NIST and Alighar Muslim University, India in order to derive improved wavelengths, energy levels, and hyperfine structure parameters.This work was partially supported by NASA, the STFC and PPARC (UK), the Royal Society of the UK

  3. Analysis of elements present in beers and brewing waters by neutron activation analysis

    International Nuclear Information System (INIS)

    Krausova, Ivana; Kucera, Jan; Dostalek, Pavel; Potesil, Vaclav

    2011-01-01

    Neutron activation analysis (NAA) was used for determination of Si, Na, K, Ca, Sc, V, Cr, Mn, Fe, Co, Zn, Rb, Cs, and La in Czech beers and brewing waters. The Si concentration in beer determined by the reaction 29 Si(n,p) 29 Al with fast neutrons confirmed that beer is an important Si source in human diet. Determination of other trace elements by NAA with the whole spectrum of reactor neutrons aimed at the feasibility of identification of Gambrinus beers brewed in various breweries. The elements Ca and V appeared to be the best candidates for this purpose. The concentrations of elements determined by NAA were also compared with the recommended daily element intake for humans. The accuracy of the method was proved by analysis of reference materials, specifically NIST SRM 2704 Buffalo River Sediment, NIST SRM 1633b Coal Fly Ash, and NIST SRM 1515 Apple Leaves. (author)

  4. Optimal Design of a Traveling-Wave Kinetic Inductance Amplifier Operated in Three-Wave Mixing Mode

    Science.gov (United States)

    Erickson, Robert; Bal, Mustafa; Ku, Ksiang-Sheng; Wu, Xian; Pappas, David

    In the presence of a DC bias, an injected pump, of frequency fP, and a signal, of frequency fS, undergo parametric three-way mixing (3WM) within a traveling-wave kinetic inductance (KIT) amplifier, producing an idler product of frequency fI =fP -fS . Periodic frequency stops are engineered into the coplanar waveguide of the device to enhance signal amplification. With fP placed just above the first frequency stop gap, 3WM broadband signal gain is achieved with maximum gain at fS =fP / 2 . Within a theory of the dispersion of traveling waves in the presence of these engineered loadings, which accounts for this broadband signal gain, we show how an optimal frequency-stop design may be constructed to achieve maximum signal amplification. The optimization approach we describe can be applied to the design of other nonlinear traveling-wave parametric amplifiers. This work was supported by the Army Research Office and the Laboratory for Physical Sciences under EAO221146, EAO241777, and the NIST Quantum Initiative. RPE acknowledges Grant 60NANB14D024 from the US Department of Commerce, NIST.

  5. Application of neutron activation analysis for the determination of essential elements in egg samples

    International Nuclear Information System (INIS)

    Gomes, Bruna G.; Maihara, Vera A.; Avegliano, Roseane P.

    2013-01-01

    The eggs are among the twenty foods consumed by the population of the five major regions of Brazil. Among the types of eggs, there are differences in nutritional value, which can vary according to the food of the bird. This study evaluating the elements Cl, K, Mg, Mn and Na considered essential micronutrients in food, because they are fundamental in several metabolic processes necessary for the maintenance and training of the human body. We analyzed three types of eggs: egg whites, of the quail, and the colonial in cooked and raw form, using the Instrumental Neutron Activation Analysis method (INAA). The egg samples were lyophilized and pulverized before analysis. To validate the methodology, reference materials NIST RM 8415 Whole Egg Powder and NIST SRM 1567 Wheat Flour were analyzed. The samples, reference materials and standards of the elements were irradiated for 20 seconds under a thermal neutron flux of 6,6x10 12 cm -2 s -1 in the nuclear research reactor IEA-R1 of IPEN-CNEN / SP. The results were consistent with the values of the Brazilian Table of Food Composition (TACO)

  6. Application of neutron activation analysis for the determination of essential elements in egg samples; Aplicacao da analise por ativacao com neutrons para a determinacao de elementos essenciais em amostras de ovos

    Energy Technology Data Exchange (ETDEWEB)

    Gomes, Bruna G.; Maihara, Vera A.; Avegliano, Roseane P., E-mail: brunagabrielegomes@gmail.com, E-mail: vmaihara@ipen.br, E-mail: pagliaro@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    The eggs are among the twenty foods consumed by the population of the five major regions of Brazil. Among the types of eggs, there are differences in nutritional value, which can vary according to the food of the bird. This study evaluating the elements Cl, K, Mg, Mn and Na considered essential micronutrients in food, because they are fundamental in several metabolic processes necessary for the maintenance and training of the human body. We analyzed three types of eggs: egg whites, of the quail, and the colonial in cooked and raw form, using the Instrumental Neutron Activation Analysis method (INAA). The egg samples were lyophilized and pulverized before analysis. To validate the methodology, reference materials NIST RM 8415 Whole Egg Powder and NIST SRM 1567 Wheat Flour were analyzed. The samples, reference materials and standards of the elements were irradiated for 20 seconds under a thermal neutron flux of 6,6x10{sup 12} cm -2 s -1 in the nuclear research reactor IEA-R1 of IPEN-CNEN / SP. The results were consistent with the values of the Brazilian Table of Food Composition (TACO)

  7. Jointly Sponsored Research Program on Energy Related Research

    Energy Technology Data Exchange (ETDEWEB)

    No, author

    2013-12-31

    Cooperative Agreements, DE-FC26-08NT43293, DOE-WRI Cooperative Research and Development Program for Fossil Energy-Related Resources began in June 2009. The goal of the Program was to develop, commercialize, and deploy technologies of value to the nation’s fossil and renewable energy industries. To ensure relevancy and early commercialization, the involvement of an industrial partner was encouraged. In that regard, the Program stipulated that a minimum of 20% cost share be achieved in a fiscal year. This allowed WRI to carry a diverse portfolio of technologies and projects at various development technology readiness levels. Depending upon the maturity of the research concept and technology, cost share for a given task ranged from none to as high as 67% (two-thirds). Over the course of the Program, a total of twenty six tasks were proposed for DOE approval. Over the period of performance of the Cooperative agreement, WRI has put in place projects utilizing a total of $7,089,581 in USDOE funds. Against this funding, cosponsors have committed $7,398,476 in private funds to produce a program valued at $14,488,057. Tables 1 and 2 presented at the end of this section is a compilation of the funding for all the tasks conducted under the program. The goal of the Cooperative Research and Development Program for Fossil Energy-Related Resources was to through collaborative research with the industry, develop or assist in the development of innovative technology solutions that will: • Increase the production of United States energy resources – coal, natural gas, oil, and renewable energy resources; • Enhance the competitiveness of United States energy technologies in international markets and assist in technology transfer; • Reduce the nation's dependence on foreign energy supplies and strengthen both the United States and regional economies; and • Minimize environmental impacts of energy production and utilization. Success of the Program can be measured by

  8. NIST Special Publication on Intrusion Detection Systems

    National Research Council Canada - National Science Library

    Bace, Rebecca Gurley

    2001-01-01

    Intrusion detection systems (IDSs) are software or hardware systems that automate the process of monitoring the events occurring in a computer system or network, analyzing them for signs of security problems...

  9. Time and Frequency Transfer Activities at NIST

    Science.gov (United States)

    2008-12-01

    differences. The graph shows data from MJD 54466 to MJD 54763 (January 1, 2008 to October 24, 2008). II.E. The Sistema Interamericano de...Metrologia (SIM) Time Network The Sistema Interamericano de Metrologia (SIM) consists of national metrology institutes (NMIs) located in the 34...designed to mitigate multipath signals. All SIM systems are connected to the Internet and upload their measurement results to Internet Web servers

  10. Final report: Bilateral key comparison SIM.T-K6.3 on humidity standards in the dew/frost-point temperature range from -30°C to 20°C

    Science.gov (United States)

    Huang, Peter; Meyer, Christopher; Brionizio, Julio D.

    2015-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the Instituto Nacional de Metrologia, Qualidade e Tecnologia (INMETRO, Brazil) between October 2009 and March 2010. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and INMETRO and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and INMETRO. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. Bilateral key comparison SIM.T-K6.5 on humidity standards in the dew/frost-point temperature range from -30 °C to +20 °C

    Science.gov (United States)

    Meyer, C.; Solano, A.

    2016-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the Laboratorio Costarricense de Metrología (LACOMET, Costa Rica) between February 2015 and August 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and LACOMET and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and LACOMET. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. Bilateral key comparison SIM.T-K6.2 on humidity standards in the dew/frost-point temperature range from -20 °c to 20 °c

    Science.gov (United States)

    Huang, P. H.; Meyer, C. W.; Martines-López, E.; Dávila Pacheco, J. A.; Méndez-Lango, E.

    2014-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the Centro Nacional de Metrologia (CENAM, Mexico) between July 2008 and December 2008. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and CENAM and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and CENAM. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  13. e-Calibrations: using the Internet to deliver calibration services in real time at lower cost

    International Nuclear Information System (INIS)

    Desrosiers, Marc; Nagy, Vitaly; Puhl, James; Glenn, Robert; Densock, Robert; Stieren, David; Lang, Brian; Kamlowski, Andreas; Maier, Diether; Heiss, Arthur

    2002-01-01

    The National Institute of Standards and Technology (NIST) is expanding into a new frontier in the delivery of measurement services. The Internet will be employed to provide industry with electronic traceability to national standards. This is a radical departure from the traditional modes of traceability and presents many new challenges. The traditional mail-based calibration service relies on sending artifacts to the user, who then mails them back to NIST for evaluation. The new service will deliver calibration results to the industry customer on-demand, in real-time, at a lower cost. The calibration results can be incorporated rapidly into the production process to ensure the highest quality manufacturing. The service would provide the US radiation processing industry with a direct link to the NIST calibration facilities and its expertise, and provide an interactive feedback process between industrial processing and the national measurement standard. Moreover, an Internet calibration system should contribute to the removal of measurement-related trade barriers

  14. Investigations at INRIM on a Pd-C cell manufactured by NPL

    Science.gov (United States)

    Battuello, M.; Florio, M.; Machin, G.

    2011-10-01

    One of a set of metal-carbon eutectic cells (a Pd-C cell, 1765 K) manufactured by NPL and used for a previous comparison of temperature scales with NIST has been investigated at INRIM. There it was implemented in two different furnaces, namely a single- and a three-zone, and measured with a standard radiation thermometer operating at 900 nm and 950 nm. Both ITS-90 and thermodynamic melting temperatures of the cell were determined by means of an extrapolation approach. The thermodynamic temperature differs by only -0.31 K from the NIST value whereas the ITS-90 temperature differs by only -0.46 K from the NPL value. The agreements, within the combined expanded uncertainties, are particularly significant, because of the different approach followed at INRIM, namely the extrapolation of multi-fixed-point scales (n = 3 and n = 4), as compared with a direct radiometric method at NIST and an ITS-90 realization traceable to the gold point at NPL.

  15. SU-E-T-259: Development of a Primary Standard for LDR Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Shen, H; McEwen, M [National Research Council, Ottawa, ON (Canada)

    2015-06-15

    Purpose: The National Research Council initiated a program in 2012 to develop a primary standard to calibrate I-125 and Pd-103 sources used for LDR brachytherapy and disseminate this through calibration services to Canadian users. This will simplify procedures as Canadian cancer centres currently have to ship instruments to the US. Methods: The standard is based on a commercial version of the wide-angle free air chamber (WAFAC) pioneered by NIST. Significant enhancements were implemented to improve signal-to-noise and measurement reproducibility and eliminate electric field effects. Validation of this ionization chamber was then carried out in a low-energy X -ray beam (∼ 31 keV) where the dose rate had been previously established using the existing NRC primary standard free-air chamber. As a final component of this initial testing, measurements were made with a set of I-125 seeds (with air kerma strength traceable to NIST). Results: Excellent agreement of the two NRC free-air chambers was obtained within the combined standard uncertainty of 0.5 %. However, it was found that the WAFAC response is very sensitive to the beam geometry (distance from the source, diameter of the beam-defining aperture, etc) and Monte Carlo calculations, carried out to evaluate these geometry corrections, have confirmed the experimental results. The results for the seed measurements indicated a precision of better than 1 % is achievable for a reasonable acquisition time and the air kerma strength agreed with the manufacturer (NIST-traceable) value within 2 %. Conclusion: The prototype primary standard for LDR brachytherapy has met accuracy target of 3 % for the determination of air kerma strength. Work is ongoing to refine operation of the device and develop the calibration protocol for clinical users, with an anticipated launch of a calibration service in late 2015.

  16. Minerals and trace elements determination in diets by neutron activation analysis; Determinacao de elementos minerais e tracos em dietas pela tecnica de ativacao neutronica

    Energy Technology Data Exchange (ETDEWEB)

    Eiras, Maria Izabel O.; Favaro, Debora I.T. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil). Lab. de Analise por Ativacao Neutronica; Ribeiro, Marisilda; Cozzolino, Silvia M.F. [Sao Paulo Univ., SP (Brazil). Dept. de Alimentos e Nutricao Experimental. Lab. de Minerais

    2002-07-01

    In the present study 12 diets, each one consisting of a pool of seven day diets, composed by four meals: breakfast, lunch, dinner and snack, adequate in energy and macro nutrients according to the RDA (Recommended Daily Allowance) recommendations, were elaborated and offered to a group of 12 men (19-42 years). The diets were collected by duplicate portion technique and dried by two different processes: freeze drying and 60 deg C ventilated oven drying. In the total, 24 diets were analyzed. The content of some minerals and trace elements (Ca, Fe, Mg, Mn, Na, Se and Zn) were determined by Instrumental Neutron Activation Analysis. The validation of methodology was made by analysis of the reference materials Typical Diet (NIST SRM 1548{sup a}), Orchard Leaves (NIST SRM 1541) and Peach Leaves (NIST SRM 1547). The results observed by two different drying processes used were statistically compared by test T of Student. It was possible to conclude that the concentration means can be considered as statistically equal, within a significance level of 0.05. The daily intake values calculated from the concentration results were: 712 ({+-} 59) mg Ca/day; 10.7 ({+-} 0.8) mg Fe/ day; 3387 ({+-} 16) mg K/ day; 275 ({+-} 6) mg Mg/ day; 3.0 ({+-} 0.5) mg Mn/ day; 3656 ({+-} 699) mg Na/ day; 42 ({+-} 6) {mu}g Se/ day e 11.6 ({+-} 2.4) mg Zn/ day. The calculated intake was compared to the new daily recommended values set by RDA (National Research Council-USA) for the range age of individuals studied. It was possible to conclude that the diets were adequate in Fe and Zn and inadequate for the other elements. Concerning the minerals Na and K we verified high daily intake levels and this was already observed in other Brazilian regional diets. (author)

  17. Minerals and trace elements determination in diets by neutron activation analysis

    International Nuclear Information System (INIS)

    Eiras, Maria Izabel O.; Favaro, Debora I.T.; Ribeiro, Marisilda; Cozzolino, Silvia M.F.

    2002-01-01

    In the present study 12 diets, each one consisting of a pool of seven day diets, composed by four meals: breakfast, lunch, dinner and snack, adequate in energy and macro nutrients according to the RDA (Recommended Daily Allowance) recommendations, were elaborated and offered to a group of 12 men (19-42 years). The diets were collected by duplicate portion technique and dried by two different processes: freeze drying and 60 deg C ventilated oven drying. In the total, 24 diets were analyzed. The content of some minerals and trace elements (Ca, Fe, Mg, Mn, Na, Se and Zn) were determined by Instrumental Neutron Activation Analysis. The validation of methodology was made by analysis of the reference materials Typical Diet (NIST SRM 1548 a ), Orchard Leaves (NIST SRM 1541) and Peach Leaves (NIST SRM 1547). The results observed by two different drying processes used were statistically compared by test T of Student. It was possible to conclude that the concentration means can be considered as statistically equal, within a significance level of 0.05. The daily intake values calculated from the concentration results were: 712 (± 59) mg Ca/day; 10.7 (± 0.8) mg Fe/ day; 3387 (± 16) mg K/ day; 275 (± 6) mg Mg/ day; 3.0 (± 0.5) mg Mn/ day; 3656 (± 699) mg Na/ day; 42 (± 6) μg Se/ day e 11.6 (± 2.4) mg Zn/ day. The calculated intake was compared to the new daily recommended values set by RDA (National Research Council-USA) for the range age of individuals studied. It was possible to conclude that the diets were adequate in Fe and Zn and inadequate for the other elements. Concerning the minerals Na and K we verified high daily intake levels and this was already observed in other Brazilian regional diets. (author)

  18. National Needs for Appearance Metrology

    Science.gov (United States)

    Nadal, Maria E.

    2003-04-01

    Appearance greatly influences a customer's judgement of the quality and acceptability of manufactured products, as yearly there is approximately $700 billion worth of shipped goods for which overall appearance is critical to their sale. For example, appearance is reported to be a major factor in about half of automobile purchases. The appearance of an object is the result of a complex interaction of the light field incident upon the object, the scattering and absorption properties of the object, and human perception. The measurable attributes of appearance are divided into color (hue, saturation, and lightness) and geometry (gloss, haze). The nature of the global economy has increased international competition and the need to improve the quality of many manufactured products. Since the manufacturing and marketing of these products is international in scope, the lack of national appearance standard artifacts and measurement protocols results in a direct loss to the supplier. One of the primary missions of the National Institute of Standards and Technology (NIST) is to strengthen the U.S. economy by working with industry to develop and apply technology, measurements and standards. The NIST Physics Laboratory has established an appearance metrology laboratory. This new laboratory provides calibration services for 0^o/45^o color standards and 20^o°, 60^o°, and 85^o° specular gloss, and research in the colorimetric characterization of gonioapparent including a new Standard Reference Material for metallic coatings (SRM 2017) and measurement protocols for pearlescent coatings. These services are NIST's first appearance metrology efforts in many years; a response to needs articulated by industry. These services are designed to meet demands for improved measurements and standards to enhance the acceptability of final products since appearance often plays a major role in their acceptability.

  19. IT Security Support for the Spaceport Command Control Systems Development Ground Support Development Operations

    Science.gov (United States)

    Branch, Drew A.

    2014-01-01

    Security is one of the most if not the most important areas today. After the several attacks on the United States, security everywhere has heightened from airports to the communication among the military branches legionnaires. With advanced persistent threats (APT's) on the rise following Stuxnet, government branches and agencies are required, more than ever, to follow several standards, policies and procedures to reduce the likelihood of a breach. Attack vectors today are very advanced and are going to continue to get more and more advanced as security controls advance. This creates a need for networks and systems to be in an updated and secured state in a launch control system environment. FISMA is a law that is mandated by the government to follow when government agencies secure networks and devices. My role on this project is to ensure network devices and systems are in compliance with NIST, as outlined in FISMA. I will achieve this by providing assistance with security plan documentation and collection, system hardware and software inventory, malicious code and malware scanning, and configuration of network devices i.e. routers and IDS's/IPS's. In addition, I will be completing security assessments on software and hardware, vulnerability assessments and reporting, and conducting patch management and risk assessments. A guideline that will help with compliance with NIST is the SANS Top 20 Critical Controls. SANS Top 20 Critical Controls as well as numerous security tools, security software and the conduction of research will be used to successfully complete the tasks given to me. This will ensure compliance with FISMA and NIST, secure systems and a secured network. By the end of this project, I hope to have carried out the tasks stated above as well as gain an immense knowledge about compliance, security tools, networks and network devices, as well as policies and procedures.

  20. Chemistry WebBook

    Science.gov (United States)

    SRD 69 NIST Chemistry WebBook (Web, free access)   The NIST Chemistry WebBook contains: Thermochemical data for over 7000 organic and small inorganic compounds; thermochemistry data for over 8000 reactions; IR spectra for over 16,000 compounds; mass spectra for over 33,000 compounds; UV/Vis spectra for over 1600 compounds; electronic and vibrational spectra for over 5000 compounds; constants of diatomic molecules(spectroscopic data) for over 600 compounds; ion energetics data for over 16,000 compounds; thermophysical property data for 74 fluids.

  1. IAEA Completes Nuclear Security Review Mission in United States

    International Nuclear Information System (INIS)

    2013-01-01

    Full text: A team of nuclear security experts led by the International Atomic Energy Agency (IAEA) today completed a mission to review nuclear security practices of civil nuclear facilities licensed by the United States Nuclear Regulatory Commission (NRC). Conducted at the U.S. Government's request, the two-week International Physical Protection Advisory Service (IPPAS) mission reviewed the United States' nuclear security-related legislative and regulatory framework. As part of this work, the IPPAS team, led by John O'Dacre of Canada and comprising nine experts from eight IAEA Member States, met with NRC officials and reviewed the physical protection systems at the Center for Neutron Research (NCNR) at the National Institute of Standards and Technology. The IPPAS team concluded that nuclear security within the U.S. civil nuclear sector is robust and sustainable and has been significantly enhanced in recent years. The team identified a number of good practices in the nation's nuclear security regime and at the NCNR. The IPPAS team also made a recommendation and some suggestions for the continuing improvement of nuclear security overall. The mission in the United States was the 60th IPPAS mission organized by the IAEA. 'Independent international peer reviews such as IAEA IPPAS missions are increasingly being recognized for their value as a key component for exchanges of views and advice on nuclear security measures', said Khammar Mrabit, Director of the IAEA Office of Nuclear Security. 'The good practices identified during this mission will contribute to the continuous improvements of nuclear security in other Member States'. The IPPAS team provided a draft report to the NRC and will submit a final report soon. Because it contains security-related information about a specific nuclear site, IPPAS reports are not made public. 'The IPPAS programme gives us a chance to learn from the experience and perspective of our international partners', said NRC Chairman Allison M

  2. Feedstock characterization and recommended procedures

    International Nuclear Information System (INIS)

    Chum, H.L.; Milne, T.A.; Johnson, D.K.; Agblevor, F.A.

    1993-01-01

    Using biomass for non-conventional applications such as feedstocks for fuels, chemicals, new materials, and electric power production requires knowledge of biomass characteristics important to these processes, and characterization techniques that are more appropriate than those employed today for conventional applications of food, feed, and fiber. This paper reviews feedstock characterization and standardization methodologies, and identifies research and development needs. It reviews the international cooperation involved in determining biomass characteristics and standards that has culminated in preparing four biomass samples currently available from the National Institute of Standards and Technology (NIST)

  3. Determination of trace elements in human brain tissues using neutron activation analysis

    International Nuclear Information System (INIS)

    Leite, R.E.P.; Jacob-Filho, W.; Grinberg, L.T.; Ferretti, R.E.L.

    2008-01-01

    Neutron activation analysis was applied to assess trace element concentrations in brain tissues from normal (n = 21) and demented individuals (n = 21) of both genders aged more than 50 years. Concentrations of the elements Br, Fe, K, Na, Rb, Se and Zn were determined. Comparisons were made between the results obtained for the hippocampus and frontal cortex tissues, as well as, those obtained in brains of normal and demented individuals. Certified reference materials, NIST 1566b Oyster Tissue and NIST 1577b Bovine Liver were analyzed for quality of the analytical results. (author)

  4. Fast- and ultra-fast laser pulse induced reactions between carbon dioxide and methane

    CSIR Research Space (South Africa)

    Kotze, FJ

    2010-03-01

    Full Text Available at 2060 cm?1 is reported to be due to the stretch mode of other organic CO bonds that may have 200 F. Jaco Kotze et al./ Journal of Natural Gas Chemistry Vol. 19 No. 2 2010 formed [13]. Results show that CO2 has been excited by the nanosecond laser...] Zewail A H. J Phys Chem A, 2000, 104: 5660 [13] http://webbook.nist.gov/chemistry:NIST Standard Reference Database Number 69. Accessed November 2008 [14] Silverstein R M, Webster F X, Kiemle D J. Spectrometric iden- tification of organic compounds...

  5. Ultrasonic slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry for the determination of Cr, Fe, Cu, Zn and Se in cereals

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Shih-Yi [Department of Chemistry, National Sun Yat-sen University, Kaohsiung 80424, Taiwan (China); Jiang, Shiuh-Jen, E-mail: sjjiang@faculty.nsysu.edu.tw [Department of Chemistry, National Sun Yat-sen University, Kaohsiung 80424, Taiwan (China); Department of Medical Laboratory Science and Biotechnology, Kaohsiung Medical University, Kaohsiung 80708, Taiwan (China); Sahayam, A.C. [National Centre for Compositional Characterisation of Materials (CCCM), Hyderabad (India)

    2014-11-01

    Ultrasonic slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry (USS-ETV-ICP-MS) has been applied to determine Cr, Fe, Cu, Zn and Se in several cereal samples. Thioacetamide was used as the modifier to enhance the ion signals. The background ions at the masses of interest were reduced in intensity significantly by using 1.0 mL min{sup −1} methane (CH{sub 4}) as reaction cell gas in the dynamic reaction cell (DRC). Since the sensitivities of Cr, Fe, Cu, Zn and Se in different matrices were quite different, standard addition and isotope dilution methods were used for the determination of Cr, Fe, Cu, Zn and Se in these cereal samples. The method detection limits estimated from standard addition curves were about 1, 10, 4, 12 and 2 ng g{sup −1} for Cr, Fe, Cu, Zn and Se, respectively, in original cereal samples. This procedure has been applied to the determination of Cr, Fe, Cu, Zn and Se whose concentrations are in μg g{sup −1} (except Cr and Se) in standard reference materials (SRM) of National institute of standards and technology (NIST), NIST SRM 1568a Rice Flour and NIST SRM 1567a Wheat Flour and two cereal samples purchased from a local market. The analysis results of reference materials agreed with certified values at 95% confidence level according to Student's T-test. The results for the real world cereal samples were also found to be in good agreement with the pneumatic nebulization DRC ICP-MS results of the sample solutions. - Highlights: • Determination of Cr, Fe, Cu, Zn and Se in cereal samples • Ultrasonic slurry sampling in combination with DRC-ICP-MS • Better sensitivity with thioacetamide modifier in ETV • Decreased sample preparation time with solid sampling • Validation with NIST SRM 1568a Rice Flour and NIST SRM 1567a Wheat Flour.

  6. Value assignment of nutrient concentrations in five standard reference materials and six reference materials.

    Science.gov (United States)

    Sharpless, K E; Gill, L M

    2000-01-01

    A number of food-matrix reference materials (RMs) are available from the National Institute of Standards and Technology (NIST) and from Agriculture Canada through NIST. Most of these materials were originally value-assigned for their elemental composition (major, minor, and trace elements), but no additional nutritional information was provided. Two of the materials were certified for selected organic constituents. Ten of these materials (Standard Reference Material [SRM] 1,563 Cholesterol and Fat-Soluble Vitamins in Coconut Oil [Natural and Fortified], SRM 1,566b Oyster Tissue, SRM 1,570a Spinach Leaves, SRM 1,974a Organics in Mussel Tissue (Mytilus edulis), RM 8,415 Whole Egg Powder, RM 8,418 Wheat Gluten, RM 8,432 Corn Starch, RM 8,433 Corn Bran, RM 8,435 Whole Milk Powder, and RM 8,436 Durum Wheat Flour) were recently distributed by NIST to 4 laboratories with expertise in food analysis for the measurement of proximates (solids, fat, protein, etc.), calories, and total dietary fiber, as appropriate. SRM 1846 Infant Formula was distributed as a quality control sample for the proximates and for analysis for individual fatty acids. Two of the materials (Whole Egg Powder and Whole Milk Powder) were distributed in an earlier interlaboratory comparison exercise in which they were analyzed for several vitamins. Value assignment of analyte concentrations in these 11 SRMs and RMs, based on analyses by the collaborating laboratories, is described in this paper. These materials are intended primarily for validation of analytical methods for the measurement of nutrients in foods of similar composition (based on AOAC INTERNATIONAL's fat-protein-carbohydrate triangle). They may also be used as "primary control materials" in the value assignment of in-house control materials of similar composition. The addition of proximate information for 10 existing reference materials means that RMs are now available from NIST with assigned values for proximates in 6 of the 9 sectors of

  7. Ultrasonic slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry for the determination of Cr, Fe, Cu, Zn and Se in cereals

    International Nuclear Information System (INIS)

    Huang, Shih-Yi; Jiang, Shiuh-Jen; Sahayam, A.C.

    2014-01-01

    Ultrasonic slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry (USS-ETV-ICP-MS) has been applied to determine Cr, Fe, Cu, Zn and Se in several cereal samples. Thioacetamide was used as the modifier to enhance the ion signals. The background ions at the masses of interest were reduced in intensity significantly by using 1.0 mL min −1 methane (CH 4 ) as reaction cell gas in the dynamic reaction cell (DRC). Since the sensitivities of Cr, Fe, Cu, Zn and Se in different matrices were quite different, standard addition and isotope dilution methods were used for the determination of Cr, Fe, Cu, Zn and Se in these cereal samples. The method detection limits estimated from standard addition curves were about 1, 10, 4, 12 and 2 ng g −1 for Cr, Fe, Cu, Zn and Se, respectively, in original cereal samples. This procedure has been applied to the determination of Cr, Fe, Cu, Zn and Se whose concentrations are in μg g −1 (except Cr and Se) in standard reference materials (SRM) of National institute of standards and technology (NIST), NIST SRM 1568a Rice Flour and NIST SRM 1567a Wheat Flour and two cereal samples purchased from a local market. The analysis results of reference materials agreed with certified values at 95% confidence level according to Student's T-test. The results for the real world cereal samples were also found to be in good agreement with the pneumatic nebulization DRC ICP-MS results of the sample solutions. - Highlights: • Determination of Cr, Fe, Cu, Zn and Se in cereal samples • Ultrasonic slurry sampling in combination with DRC-ICP-MS • Better sensitivity with thioacetamide modifier in ETV • Decreased sample preparation time with solid sampling • Validation with NIST SRM 1568a Rice Flour and NIST SRM 1567a Wheat Flour

  8. The Role of Emerging Energy-Efficient Technology in PromotingWorkplace Productivity and Health: Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Satish; Fisk, William J.

    2002-02-13

    Research into indoor environmental quality (IEQ) and itseffects on health, comfort, and performance of occupants is becoming anincreasing priority as interest in high performance buildings andorganizational productivity advances. Facility managers are interested inIEQ's close relationship to energy use in facilities and employers wantto enhance employee comfort and productivity, reduce absenteeism andhealth costs, and reduce or even eliminate litigation by providingexcellent indoor environments to employees. The increasing interest inthis field as architects, engineers, facility managers, buildinginvestors, health officials, jurists, and the public seek simple andgeneral guidelines on creating safe, healthy, and comfortable indoorenvironment, has put additional pressure on the research community. Inthe last twenty years, IEQresearchers have advanced our understanding ofthe influence of IEQ on health and productivity, but many uncertaintiesremain. Consequently, there is a critical need to expand research in thisfield, particularly research that is highly multidisciplinary. Inaddition, there is a strong need to better communicate knowledgecurrently documented in research publications to building professionalsin order to encourage implementation of designs and practices thatenhance health and productivity. Against this background, the IndoorHealth and Productivity (IHP) project aims to develop a fullerunderstanding of the relationships between physical attributes of theworkplace (e.g. thermal, lighting, ventilation, and air quality) innon-residential and non-industrial buildings and the health andproductivity of occupants. A particular emphasis of the IHP project is toidentify and communicate key research findings, with their practical andpolicy implications, to policymakers, design practitioners, facilitymanagers, construction and energy services companies, and buildinginvestors.The IHP project has a steering committee of sponsors and seniorscientists. Advisory

  9. Trapped atomic ions for quantum-limited metrology

    Science.gov (United States)

    Wineland, David

    2017-04-01

    Laser-beam-manipulated trapped ions are a candidate for large-scale quantum information processing and quantum simulation but the basic techniques used can also be applied to quantum-limited metrology and sensing. Some examples being explored at NIST are: 1) As charged harmonic oscillators, trapped ions can be used to sense electric fields; this can be used to characterize the electrode-surface-based noisy electric fields that compromise logic-gate fidelities and may eventually be used as a tool in surface science. 2) Since typical qubit logic gates depend on state-dependent forces, we can adapt the gate dynamics to sensitively detect additional forces. 3) We can use extensions of Bell inequality measurements to further restrict the degree of local realism possessed by Bell states. 4) We also briefly describe experiments for creation of Bell states using Hilbert space engineering. This work is a joint effort including the Ion-Storage group, the Quantum processing group, and the Computing and Communications Theory group at NIST, Boulder. Supported by IARPA, ONR, and the NIST Quantum Information Program.

  10. Marine mammal blubber reference and control materials for use in the determination of halogenated organic compounds and fatty acids

    Energy Technology Data Exchange (ETDEWEB)

    Kucklick, John R.; Pugh, Rebecca S.; Becker, Paul R. [Hollings Marine Laboratory, National Institute of Standards and Technology (NIST), Charleston, SC (United States); Schantz, Michele M.; Porter, Barbara J.; Poster, Dianne L.; Leigh, Stefan; Wise, Stephen A. [NIST, Analytical Chemistry Division, Gaithersburg, MD (United States); Rowles, Teri K. [National Marine Fisheries Service, National Oceanic and Atmospheric Administration, Silver Spring, MD (United States)

    2010-05-15

    The National Institute of Standards and Technology (NIST) has a diverse collection of control materials derived from marine mammal blubber, fat, and serum. Standard Reference Material (SRM) 1945 Organics in Whale Blubber was recertified for polychlorinated biphenyl (PCB) congeners, organochlorine pesticides, and polybrominated diphenyl ether (PBDE) congeners. SRM 1945 has also been assigned mass fraction values for compounds not frequently determined in marine samples including toxaphene congeners, coplanar PCBs, and methoxylated PBDE congeners which are natural products. NIST also has assigned mass fraction values, as a result of interlaboratory comparison exercises, for PCB congeners, organochlorine pesticides, PBDE congeners, and fatty acids in six homogenate materials produced from marine mammal blubber or serum. The materials are available from NIST upon request; however, the supply is very limited for some of the materials. The materials include those obtained from pilot whale blubber (Homogenates III and IV), Blainville's beaked whale blubber (Homogenate VII), polar bear fat (Homogenate VI), and California sea lion serum (Marine Mammal Control Material-1 Serum) and blubber (Homogenate V). (orig.)

  11. Nicolas Lyon-Caen , La boîte à Perrette, le jansénisme parisien au xviiie siècle

    OpenAIRE

    Vermander, Benoît

    2012-01-01

    Nicolas Lyon-­­­Caen publie ici sa thèse sou­­te­­nue en 2008 à l’uni­­ver­­sité Paris I (dir. Cl. Mi­­­chaud) sous le titre Mar­­chands de miracles. La bour­­geoi­­sie jan­­sé­­niste pari­­sienne au xviiie siècle, elle-­­­même pro­­lon­­ge­­ment d’une thèse de l’École des Chartes consa­­crée au finan­­ce­­ment du « parti » jan­­sé­­niste au xviiie siècle (La boîte à Perrette, 2002). Ce n’est donc pas une his­­toire de l’ensemble des jan­­sé­­nistes pari­­siens que l’on trou­­vera dans cet ou...

  12. Theoretical Study of Energy Levels and Transition Probabilities of Boron Atom

    Science.gov (United States)

    Tian Yi, Zhang; Neng Wu, Zheng

    2009-08-01

    Full Text PDF Though the electrons configuration for boron atom is simple and boron atom has long been of interest for many researchers, the theoretical studies for properties of BI are not systematic, there are only few results reported on energy levels of high excited states of boron, and transition measurements are generally restricted to transitions involving ground states and low excited states without considering fine structure effects, provided only multiplet results, values for transitions between high excited states are seldom performed. In this article, by using the scheme of the weakest bound electron potential model theory calculations for energy levels of five series are performed and with the same method we give the transition probabilities between excited states with considering fine structure effects. The comprehensive set of calculations attempted in this paper could be of some value to workers in the field because of the lack of published calculations for the BI systems. The perturbations coming from foreign perturbers are taken into account in studying the energy levels. Good agreement between our results and the accepted values taken from NIST has been obtained. We also reported some values of energy levels and transition probabilities not existing on the NIST data bases.

  13. First measurement of 153Sm in the SIR

    International Nuclear Information System (INIS)

    Michotte, C.; Ratel, G.; Lucas, L.

    1999-01-01

    In June 1998, the NIST sent to the International Reference System (SIR) a solution of 153 Sm standardized in a 4π ionization chamber. As this radionuclide had not previously been measured in the SIR, the resulting equivalent activity A e,NIST is compared with the value calculated from the efficiency curve of the SIR. However, problems occurred owing to the presence of 154 Eu and 156 Eu impurities in the solution. The manner in which the final equivalent activity value for this solution of 153 Sm has been deduced is described in this report. (authors)

  14. A Long-Term Comparison of GPS Carrierphase Frequency Transfer and Two-Way Satellite Time/Frequency Transfer

    Science.gov (United States)

    2007-01-01

    14 1.E-13 1.E+03 1.E+04 1.E+05 1.E+06 1.E+07 AVERAGING TIME τ (s) O V E R LA P P IN G σ y ( τ )/T H E O _B R (F R A C F R E Q ) METAS-NIST NPL-NIST... Metrologia , 42, 411-422. [2] C. Hackman, J. Levine, T. E. Parker, D. Piester and J. Becker, 2006, “A Straightforward Frequency- Estimation Technique for... Metrologia , 43, 109-120. [6] http://igscb.jpl.nasa.gov [7] G. Blewitt, 1989, “Carrier-Phase Ambiguity Resolution for the Global Positioning System Applied

  15. Determination of Rare Earth Elements in plants by neutron activation analysis

    International Nuclear Information System (INIS)

    Figueiredo, Ana M.G.; Maria, Sheila P.; Ceccantini, Gregorio C.T.

    1996-01-01

    In the present work, instrumental neutron activation analysis was employed to the determination of rare earth elements (La, Ce, Nd, Eu, Tb, Yb e Lu) in plants, aiming biogeochemical studies. The precision and accuracy of the method were verified by the analysis of the reference materials Citrus Leaves (NIST 1572) and Pine Needles (NIST 1575). With exception of terbium, the results obtained agreed with reference values, giving relative errors less than 25%. The method was applied to different species of plants growing in the alkaline-ultramafic complex of Salitre, MG and the obtained data were compared to the average content in plants. (author)

  16. Mathematics and Measurement.

    Science.gov (United States)

    Boisvert, R F; Donahue, M J; Lozier, D W; McMichael, R; Rust, B W

    2001-01-01

    In this paper we describe the role that mathematics plays in measurement science at NIST. We first survey the history behind NIST's current work in this area, starting with the NBS Math Tables project of the 1930s. We then provide examples of more recent efforts in the application of mathematics to measurement science, including the solution of ill-posed inverse problems, characterization of the accuracy of software for micromagnetic modeling, and in the development and dissemination of mathematical reference data. Finally, we comment on emerging issues in measurement science to which mathematicians will devote their energies in coming years.

  17. 76 FR 46279 - Smart Grid Advisory Committee

    Science.gov (United States)

    2011-08-02

    ...The Smart Grid Advisory Committee (SGAC or Committee) will hold a meeting via teleconference on Tuesday, August 23, 2011 from 11 a.m. to 2 p.m. Eastern Time (E.T.). The primary purpose of this meeting is to review sections of the Committee's draft report to the NIST Director. The sections of the draft report that the Committee will consider at the meeting will be posted on the SGAC Web site at http:// www.nist.gov/smartgrid. Interested members of the public will be able to participate in the meeting from remote locations by calling into a central phone number.

  18. The DARPA quantum network

    International Nuclear Information System (INIS)

    Elliot, B.

    2005-01-01

    Full text: The DARPA quantum network is now in initial operational, with six nodes performing quantum cryptography 24x7 across the Boston metro area between our campuses at Harvard University, Boston University, and BBN Technologies. In this talk, we present our recent activities, including the deployment of this network, building our Mark 1 Entangled QKD system, porting BBN QKD protocol software to NIST and Qinetiq freespace systems, performing initial design of a superconducting single photon detector with U. Rochester and NIST Boulder, and implementing a novel Low-Density Parity Check (LDPC) protocol for QKD. (author)

  19. The Kelvin and Temperature Measurements

    Science.gov (United States)

    Mangum, B. W.; Furukawa, G. T.; Kreider, K. G.; Meyer, C. W.; Ripple, D. C.; Strouse, G. F.; Tew, W. L.; Moldover, M. R.; Johnson, B. Carol; Yoon, H. W.; Gibson, C. E.; Saunders, R. D.

    2001-01-01

    The International Temperature Scale of 1990 (ITS-90) is defined from 0.65 K upwards to the highest temperature measurable by spectral radiation thermometry, the radiation thermometry being based on the Planck radiation law. When it was developed, the ITS-90 represented thermodynamic temperatures as closely as possible. Part I of this paper describes the realization of contact thermometry up to 1234.93 K, the temperature range in which the ITS-90 is defined in terms of calibration of thermometers at 15 fixed points and vapor pressure/temperature relations which are phase equilibrium states of pure substances. The realization is accomplished by using fixed-point devices, containing samples of the highest available purity, and suitable temperature-controlled environments. All components are constructed to achieve the defining equilibrium states of the samples for the calibration of thermometers. The high quality of the temperature realization and measurements is well documented. Various research efforts are described, including research to improve the uncertainty in thermodynamic temperatures by measuring the velocity of sound in gas up to 800 K, research in applying noise thermometry techniques, and research on thermocouples. Thermometer calibration services and high-purity samples and devices suitable for “on-site” thermometer calibration that are available to the thermometry community are described. Part II of the paper describes the realization of temperature above 1234.93 K for which the ITS-90 is defined in terms of the calibration of spectroradiometers using reference blackbody sources that are at the temperature of the equilibrium liquid-solid phase transition of pure silver, gold, or copper. The realization of temperature from absolute spectral or total radiometry over the temperature range from about 60 K to 3000 K is also described. The dissemination of the temperature scale using radiation thermometry from NIST to the customer is achieved by

  20. Prompt Neutron Lifetime for the NBSR Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Hanson, A.L.; Diamond, D.

    2012-06-24

    In preparation for the proposed conversion of the National Institute of Standards and Technology (NIST) research reactor (NBSR) from high-enriched uranium (HEU) to low-enriched uranium (LEU) fuel, certain point kinetics parameters must be calculated. We report here values of the prompt neutron lifetime that have been calculated using three independent methods. All three sets of calculations demonstrate that the prompt neutron lifetime is shorter for the LEU fuel when compared to the HEU fuel and longer for the equilibrium end-of-cycle (EOC) condition when compared to the equilibrium startup (SU) condition for both the HEU and LEU fuels.

  1. The MITLL NIST LRE 2015 Language Recognition System

    Science.gov (United States)

    2016-05-06

    Cluster Target Classes Arabic Egyptian , Iraqi, Levantine, Maghrebi, Modern Standard Chinese Cantonese, Mandarin, Min, Wu English...42.69 Egyptian (ara-arz) 440 97.27 British English (eng-gbr) 47 0.51 Indian English (eng-sas) 418 7.82 American English (eng-usg) 428 100.37...are obtained by training a Deep Neural Network (DNN) using a seven hidden layer architecture . On these systems, all hidden layers have 1024 nodes

  2. Toward a Multi-City Framework for Urban GHG Estimation in the United States: Methods, Uncertainties, and Future Goals

    Science.gov (United States)

    Mueller, K. L.; Callahan, W.; Davis, K. J.; Dickerson, R. R.; Duren, R. M.; Gurney, K. R.; Karion, A.; Keeling, R. F.; Kim, J.; Lauvaux, T.; Miller, C. E.; Shepson, P. B.; Turnbull, J. C.; Weiss, R. F.; Whetstone, J. R.

    2017-12-01

    City and State governments are increasingly interested in mitigating greenhouse gas (GHG) emissions to improve sustainability within their jurisdictions. Estimation of urban GHG emissions remains an active research area with many sources of uncertainty. To support the effort of improving measurement of trace gas emissions in city environments, several federal agencies along with academic, research, and private entities have been working within a handful of domestic metropolitan areas to improve both (1) the assessment of GHG emissions accuracy using a variety of measurement technologies, and (2) the tools that can better assess GHG inventory data at urban mitigation scales based upon these measurements. The National Institute of Standards and Technology (NIST) activities have focused on three areas, or testbeds: Indianapolis (INFLUX experiment), Los Angeles (the LA Megacities project), and the Northeastern Corridor areas encompassing Washington and Baltimore (the NEC/BW GHG Measurements project). These cities represent diverse meteorological, terrain, demographic, and emissions characteristics having a broad range of complexities. To date this research has involved multiple measurement systems and integrated observing approaches, all aimed at advancing development of a robust, science-base upon which higher accuracy quantification approaches can rest. Progress toward such scientifically robust, widely-accepted emissions quantification methods will rely upon continuous performance assessment. Such assessment is challenged by the complexities of cities themselves (e.g., population, urban form) along with the many variables impacting a city's technological ability to estimate its GHG emissions (e.g., meteorology, density of observations). We present the different NIST testbeds and a proposal to initiate conceptual development of a reference framework supporting the comparison of multi-city GHG emissions estimates. Such a reference framework has potential to provide

  3. Specific NIST projects in support of the NIJ Concealed Weapon Detection and Imaging Program

    Science.gov (United States)

    Paulter, Nicholas G.

    1998-12-01

    The Electricity Division of the National Institute of Standards and Technology is developing revised performance standards for hand-held (HH) and walk-through (WT) metal weapon detectors, test procedures and systems for these detectors, and a detection/imaging system for finding concealed weapons. The revised standards will replace the existing National Institute of Justice (NIJ) standards for HH and WT devices and will include detection performance specifications as well as system specifications (environmental conditions, mechanical strength and safety, response reproducibility and repeatability, quality assurance, test reporting, etc.). These system requirements were obtained from the Law Enforcement and corrections Technology Advisory Council, an advisory council for the NIJ. Reproducible and repeatable test procedures and appropriate measurement systems will be developed for evaluating HH and WT detection performance. A guide to the technology and application of non- eddy-current-based detection/imaging methods (such as acoustic, passive millimeter-wave and microwave, active millimeter-wave and terahertz-wave, x-ray, etc.) Will be developed. The Electricity Division is also researching the development of a high- frequency/high-speed (300 GH to 1 THz) pulse-illuminated, stand- off, video-rate, concealed weapons/contraband imaging system.

  4. Evaluation of extraction methods for hexavalent chromium determination in dusts, ashes, and soils

    Science.gov (United States)

    Wolf, Ruth E.; Wilson, Stephen A.

    2010-01-01

    One of the difficulties in performing speciation analyses on solid samples is finding a suitable extraction method. Traditional methods for extraction of hexavalent chromium, Cr(VI), in soils, such as SW846 Method 3060A, can be tedious and are not always compatible with some determination methods. For example, the phosphate and high levels of carbonate and magnesium present in the U.S. Environmental Protection Agency (USEPA) Method 3060A digestion for Cr(VI) were found to be incompatible with the High Performance Liquid Chromatography-Inductively Coupled Plasma-Mass Spectrometry (HPLC-ICP-MS) detection method used by our laboratory. Modification of Method 3060A by eliminating the use of the phosphate buffer provided improved performance with the detection method, however dilutions are still necessary to achieve good chromatographic separation and detection of Cr(VI). An ultrasonic extraction method using a 1 mM Na2CO3 - 9 mM NaHCO3 buffer solution, adapted from Occupational Safety and Health Administration (OSHA) Method ID215, has been used with good results for the determination of Cr(VI) in air filters. The average recovery obtained for BCR-545 - Welding Dust Loaded on Filter (IRMM, Belgium) using this method was 99 percent (1.2 percent relative standard deviation) with no conversion of Cr(VI) to Cr(III) during the extraction process. This ultrasonic method has the potential for use with other sample matrices, such as ashes and soils. Preliminary investigations using NIST 2701 (Hexavalent Chromium in Contaminated Soil) loaded onto quartz filters showed promising results with approximately 90 percent recovery of the certified Cr(VI) value. Additional testing has been done using NIST 2701 and NIST 2700 using different presentation methods. Extraction efficiency of bulk presentation, where small portions of the sample are added to the bottom of the extraction vessel, will be compared with supported presentation, where small portions of the sample are loaded onto a

  5. Primary calibration of coiled 103Pd brachytherapy sources

    International Nuclear Information System (INIS)

    Paxton, Adam B.; Culberson, Wesley S.; DeWerd, Larry A.; Micka, John A.

    2008-01-01

    Coiled 103 Pd brachytherapy sources have been developed by RadioMed Corporation for use as low-dose-rate (LDR) interstitial implants. The coiled sources are provided in integer lengths from 1 to 6 cm and address many common issues seen with traditional LDR brachytherapy sources. The current standard for determining the air-kerma strength (S K ) of low-energy LDR brachytherapy sources is the National Institute of Standards and Technology's Wide-Angle Free-Air Chamber (NIST WAFAC). Due to geometric limitations, however, the NIST WAFAC is unable to determine the S K of sources longer than 1 cm. This project utilized the University of Wisconsin's Variable-Aperture Free-Air Chamber (UW VAFAC) to determine the S K of the longer coiled sources. The UW VAFAC has shown agreement in S K values of 1 cm length coils to within 1% of those determined with the NIST WAFAC, but the UW VAFAC does not share the same geometric limitations as the NIST WAFAC. A new source holder was constructed to hold the coiled sources in place during measurements with the UW VAFAC. Correction factors for the increased length of the sources have been determined and applied to the measurements. Using the new source holder and corrections, the S K of 3 and 6 cm coiled sources has been determined. Corrected UW VAFAC data and ionization current measurements from well chambers have been used to determine calibration coefficients for use in the measurement of 3 and 6 cm coiled sources in well chambers. Thus, the UW VAFAC has provided the first transferable, primary measurement of low-energy LDR brachytherapy sources with lengths greater than 1 cm

  6. Application of slurry nebulization to trace elemental analysis of some biological samples by inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Mochizuki, T.; Sakashita, A.; Iwata, H.; Ishibashi, Y.; Gunji, N.

    1991-01-01

    The application of slurry nebulization/inductively coupled plasma mass spectrometry (ICP-MS) to trace elemental analysis of biological samples has been investigated. Three standard samples of the National Institute of Standards and Technology (NIST) were dispersed in 1% aqueous Triton X-100 solution by grinding with a planetary micronizing mill. The resulting slurries were nebulized into an ICP without any additional treatments. The 1% (m/v) slurry of the NIST bovine liver showed no significant influence on cone blockage and signal suppression/enhancement. Detection limit, precision and accuracy were discussed for the determination of 24 elements of interest in bovine liver, rice flour and pine needles. Detection limits ranged from 0.0001 μg g -1 for U to 0.52 μg g -1 for Zn at the effective integrating time of 10 s. For high mass elements, low blank values were obtained, yielding excellent limits ( -1 ). Acceptable accuracy and precision were obtained for most of the elements in the NIST bovine liver and rice flour, even for the volatile elements, such as As, Se and Br. However, relatively poor accuracy was obtained for the analysis of pine needles. (orig.)

  7. Calibration services for medical applications of radiation

    Energy Technology Data Exchange (ETDEWEB)

    DeWerd, L.A.

    1993-12-31

    Calibration services for the medical community applications of radiation involve measuring radiation precisely and having traceability to the National Institute of Standards and Technology (NIST). Radiation therapy applications involve the use of ionization chambers and electrometers for external beams and well-type ionization chamber systems as well as radioactive sources for brachytherapy. Diagnostic x-ray applications involve ionization chamber systems and devices to measure other parameters of the x-ray machine, such as non-invasive kVp meters. Calibration laboratories have been established to provide radiation calibration services while maintaining traceability to NIST. New radiation applications of the medical community spur investigation to provide the future calibration needs.

  8. On neutron activation analysis with γγ coincidence spectrometry

    International Nuclear Information System (INIS)

    Zeisler, Rolf; Danyal Turkoglu; Ibere Souza Ribeiro Junior; Shetty, M.G.

    2017-01-01

    A new γγ coincidence system has been set up at NIST. It is operated with a digital data finder supported by new software developed at NIST. The system is used to explore possible enhancements in instrumental neutron activation analysis (INAA) and study applicability to neutron capture prompt gamma activation analysis (PGAA). The performance of the system is tested with certified reference materials for efficiency calibration and quantitative performance. Comparisons of INAA results based on conventional gamma-ray spectrometry data with INAA results based on coincidence data obtained from the same samples show improvements in the counting uncertainties and demonstrates the quantitative accuracy of the new system. (author)

  9. A transferability study of the EPR-tooth-dosimetry technique

    International Nuclear Information System (INIS)

    Sholom, S.; Chumak, V.; Desrosiers, M.; Bouville, A.

    2006-01-01

    The transferability of a measurement protocol from one laboratory to another is an important feature of any mature, standardised protocol. The electron paramagnetic resonance (EPR)-tooth dosimetry technique that was developed in Scientific Center for Radiation Medicine, AMS (Ukraine) (SCRM) for routine dosimetry of Chernobyl liquidators has demonstrated consistent results in several inter-laboratory measurement comparisons. Transferability to the EPR dosimetry laboratory at the National Inst. of Standards and Technology (NIST) was examined. Several approaches were used to test the technique, including dose reconstruction of SCRM-NIST inter-comparison samples. The study has demonstrated full transferability of the technique and the possibility to reproduce results in a different laboratory environment. (authors)

  10. Preparation of high purity plutonium oxide for radiochemistry instrument calibration standards and working standards

    International Nuclear Information System (INIS)

    Wong, A.S.; Stalnaker, N.D.

    1997-04-01

    Due to the lack of suitable high level National Institute of Standards and Technology (NIST) traceable plutonium solution standards from the NIST or commercial vendors, the CST-8 Radiochemistry team at Los Alamos National Laboratory (LANL) has prepared instrument calibration standards and working standards from a well-characterized plutonium oxide. All the aliquoting steps were performed gravimetrically. When a 241 Am standardized solution obtained from a commercial vendor was compared to these calibration solutions, the results agreed to within 0.04% for the total alpha activity. The aliquots of the plutonium standard solutions and dilutions were sealed in glass ampules for long term storage

  11. Calibration services for medical applications of radiation

    International Nuclear Information System (INIS)

    DeWerd, L.A.

    1993-01-01

    Calibration services for the medical community applications of radiation involve measuring radiation precisely and having traceability to the National Institute of Standards and Technology (NIST). Radiation therapy applications involve the use of ionization chambers and electrometers for external beams and well-type ionization chamber systems as well as radioactive sources for brachytherapy. Diagnostic x-ray applications involve ionization chamber systems and devices to measure other parameters of the x-ray machine, such as non-invasive kVp meters. Calibration laboratories have been established to provide radiation calibration services while maintaining traceability to NIST. New radiation applications of the medical community spur investigation to provide the future calibration needs

  12. 76 FR 12711 - Smart Grid Advisory Committee

    Science.gov (United States)

    2011-03-08

    ...The Smart Grid Advisory Committee (SGAC or Committee), will hold a meeting on Thursday, March 24, 2011 from 8:30 a.m. to 5 p.m. The primary purpose of this meeting is to review the early findings and observations of each Subcommittee, strategize the Table of Contents for the Committee report to NIST, agree on the page limit for each subcommittee, and look for any common overarching themes. There will also be breakouts for each subcommittee to meet individually. The agenda may change to accommodate Committee business. The final agenda will be posted on the Smart Grid Web site at http:// www.nist.gov/smartgrid.

  13. Industrial Physics Careers: A Large Company Perspective

    Science.gov (United States)

    Zollner, Stefan

    2009-03-01

    Statistical data from the American Institute of Physics and the National Science Foundation show that only about a third of physics graduates get permanent jobs in academia. A few work in government labs and hospitals. The majority of physics Ph.D.s, however, find employment in the private sector (industry). This trend has been increasing, i.e., recent Ph.D.s are even more likely to start careers in industry. Industrial physicists work in small, medium or large companies in a broad range of fields, including aerospace, semiconductors, automotive, energy, information technology, contract research, medical, chemical, optics, etc. They are also represented in fields outside of physics, such as finance. Even the ``inventor'' of the Powerball lottery game is a Ph.D. physicist. In my talk, I will describe pathways to success for an industrial physicist, from the perspective of employment in three different large corporations. Based on the NIST Baldridge criteria of Performance Excellence, I will discuss how to achieve and measure organizational success through focus on products and customers. Individual performance is linked to the goals of the organization. Performance has two components: Goals and behaviors. Both are key to success as an individual contributor or manager.[4pt] References: [0pt] http://www.aip.org/statistics/trends/emptrends.html [0pt] http://www.aps.org/about/governance/committees/commemb/index.cfm [0pt] http://www.quality.nist.gov/

  14. Re-evaluation and extension of the scope of elements in US Geological Survey Standard Reference Water Samples

    Science.gov (United States)

    Peart, D.B.; Antweiler, Ronald C.; Taylor, Howard E.; Roth, D.A.; Brinton, T.I.

    1998-01-01

    More than 100 US Geological Survey (USGS) Standard Reference Water Samples (SRWSs) were analyzed for numerous trace constituents, including Al, As, B, Ba, Be, Bi, Br, Cd, Cr, Co, Cu, I, Fe, Pb, Li, Mn, Mo, Ni, Rb, Sb, Se, Sr, Te, Tl, U, V, Zn and major elements (Ca, Mg, Na, SiO2, SO4, Cl) by inductively coupled plasma mass spectrometry and inductively coupled plasma atomic emission spectrometry. In addition, 15 USGS SRWSs and National Institute of Standards and Technology (NIST) standard reference material (SRM) 1641b were analyzed for mercury using cold vapor atomic fluorescence spectrometry. Also USGS SRWS Hg-7 was analyzed using isotope dilution-inductively coupled plasma mass spectrometry. The results were compared with the reported certified values of the following standard reference materials: NIST SRM 1643a, 1643b, 1643c and 1643d and National Research Council of Canada Riverine Water Reference Materials for Trace Metals SLRS-1, SLRS-2 and SLRS-3. New concentration values for trace and major elements in the SRWSs, traceable to the certified standards, are reported. Additional concentration values are reported for elements that were neither previously published for the SRWSs nor traceable to the certified reference materials. Robust statistical procedures were used that were insensitive to outliers. These data can be used for quality assurance/quality control purposes in analytical laboratories.

  15. Mobile Solar Tracker Facility

    Data.gov (United States)

    Federal Laboratory Consortium — NIST's mobile solar tracking facility is used to characterize the electrical performance of photovoltaic panels. It incorporates meteorological instruments, a solar...

  16. 40 CFR 86.1306-07 - Equipment required and specifications; overview.

    Science.gov (United States)

    2010-07-01

    ... the hardware and software included in the alternate system. Dimensioned drawings, flow-charts... NIST traceable standards, or equivalent national standards. Diagrams, schematics, and other graphics...

  17. Application of cryogenic grinding to achieve homogenization of transuranic wastes

    International Nuclear Information System (INIS)

    Atkins, W.H.; Hill, D.D.; Lucero, M.E.; Jaramillo, L.; Martinez, H.E.

    1996-08-01

    This paper describes work done at Los Alamos National Laboratory (LANL) in collaboration with the Department of Energy Rocky Flats Field Office (DOE/RFFO) and with the National Institute of Standards and Technology (NIST), Boulder, Colorado. Researchers on this project have developed a method for cryogenic grinding of mixed wastes to homogenize and, thereby, to acquire a representative sample of the materials. There are approximately 220,000 waste drums owned by the Rocky Flats Environmental Technology Site (RFETS)-50,000 at RFETS and 170,000 at the Idaho National Engineering Laboratory. The cost of sampling the heterogeneous distribution of waste in each drum is prohibitive. In an attempt to produce a homogeneous mixture of waste that would reduce greatly the cost of sampling, researchers at NIST and RFETS are developing a cryogenic grinder. The Los Alamos work herein described addresses the implementation issues of the task. The first issue was to ascertain whether samples of the open-quotes small particleclose quotes mixtures of materials present in the waste drums at RFETS were representative of actual drum contents. Second, it was necessary to determine at what temperature the grinding operation must be performed in order to minimize or to eliminate the release of volatile organic compounds present in the waste. Last, it was essential to evaluate any effect the liquid cryogen might have on the structural integrity and ventilation capacity of the glovebox system. Results of this study showed that representative samples could be and had been obtained, that some release of organics occurred below freezing because of sublimation, and that operation of the cryogenic grinding equipment inside the glovebox was feasible

  18. WE-DE-201-05: Evaluation of a Windowless Extrapolation Chamber Design and Monte Carlo Based Corrections for the Calibration of Ophthalmic Applicators

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, J; Culberson, W; DeWerd, L [University of Wisconsin Medical Radiation Research Center, Madison, WI (United States); Soares, C [NIST (retired), Gaithersburg, MD (United States)

    2016-06-15

    Purpose: To test the validity of a windowless extrapolation chamber used to measure surface dose rate from planar ophthalmic applicators and to compare different Monte Carlo based codes for deriving correction factors. Methods: Dose rate measurements were performed using a windowless, planar extrapolation chamber with a {sup 90}Sr/{sup 90}Y Tracerlab RA-1 ophthalmic applicator previously calibrated at the National Institute of Standards and Technology (NIST). Capacitance measurements were performed to estimate the initial air gap width between the source face and collecting electrode. Current was measured as a function of air gap, and Bragg-Gray cavity theory was used to calculate the absorbed dose rate to water. To determine correction factors for backscatter, divergence, and attenuation from the Mylar entrance window found in the NIST extrapolation chamber, both EGSnrc Monte Carlo user code and Monte Carlo N-Particle Transport Code (MCNP) were utilized. Simulation results were compared with experimental current readings from the windowless extrapolation chamber as a function of air gap. Additionally, measured dose rate values were compared with the expected result from the NIST source calibration to test the validity of the windowless chamber design. Results: Better agreement was seen between EGSnrc simulated dose results and experimental current readings at very small air gaps (<100 µm) for the windowless extrapolation chamber, while MCNP results demonstrated divergence at these small gap widths. Three separate dose rate measurements were performed with the RA-1 applicator. The average observed difference from the expected result based on the NIST calibration was −1.88% with a statistical standard deviation of 0.39% (k=1). Conclusion: EGSnrc user code will be used during future work to derive correction factors for extrapolation chamber measurements. Additionally, experiment results suggest that an entrance window is not needed in order for an extrapolation

  19. 76 FR 3877 - Effectiveness of Federal Agency Participation in Standardization in Select Technology Sectors for...

    Science.gov (United States)

    2011-01-21

    .... Health Information Technology. 3. Cyber Security. 4. Emergency Communications Interoperability. 5... and Business Affairs at [email protected] or 301-975-NIST (6478). SUPPLEMENTARY INFORMATION: On...

  20. Kaasaegne memento mori / Annika Toots

    Index Scriptorium Estoniae

    Toots, Annika

    2015-01-01

    Hispaania fotokunstnikust Tatiana Abellánist, kelle doktorantuuri uurimisteemaks Murcia ülikoolis oli surma kujutamine ja estetiseerimine kunstis. Tema huvist vanade fotode vastu, seeriast "Fuisteis yo"

  1. The verification of neutron activation analysis support system (cooperative research)

    Energy Technology Data Exchange (ETDEWEB)

    Sasajima, Fumio; Ichimura, Shigeju; Ohtomo, Akitoshi; Takayanagi, Masaji [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Sawahata, Hiroyuki; Ito, Yasuo [Tokyo Univ. (Japan). Research Center for Nuclear Science and Technology; Onizawa, Kouji [Radiation Application Development Association, Tokai, Ibaraki (Japan)

    2000-12-01

    Neutron activation analysis support system is the system in which even the user who has not much experience in the neutron activation analysis can conveniently and accurately carry out the multi-element analysis of the sample. In this verification test, subjects such functions, usability, precision and accuracy of the analysis and etc. of the neutron activation analysis support system were confirmed. As a method of the verification test, it was carried out using irradiation device, measuring device, automatic sample changer and analyzer equipped in the JRR-3M PN-3 facility, and analysis software KAYZERO/SOLCOI based on the k{sub 0} method. With these equipments, calibration of the germanium detector, measurement of the parameter of the irradiation field and analysis of three kinds of environmental standard sample were carried out. The k{sub 0} method adopted in this system is primarily utilized in Europe recently, and it is the analysis method, which can conveniently and accurately carried out the multi-element analysis of the sample without requiring individual comparison standard sample. By this system, total 28 elements were determined quantitatively, and 16 elements with the value guaranteed as analytical data of the NIST (National Institute of Standards and Technology) environment standard sample were analyzed in the accuracy within 15%. This report describes content and verification result of neutron activation support system. (author)

  2. Introduction

    OpenAIRE

    Chartier, Pierre

    2007-01-01

    De Diderot à l’Encyclopédie et à l’Idéologie, de l’opposition janséniste au carnaval des fous, le sommaire de ce n° 25 offre un bon exemple de la richesse et de la diversité des objets qui nous occupent.Jean Sgard, d’abord, interroge l’image que les Nouvelles ecclésias­tiques ont donnée de Denis Diderot, cet incrédule qui a peut-être été un temps, au collège d’Harcourt, le disciple de maîtres jansénistes. Or on ne trouve que quelques rares mentions de celui qui fut sans conteste l’un des adve...

  3. Synthesis, characterization and application of ion imprinted poly(vinylimidazole for zinc ion extraction/preconcentration with faas determination

    Directory of Open Access Journals (Sweden)

    Queila O. dos Santos

    2014-01-01

    Full Text Available In this paper, we describe the synthesis of an ion imprinted polymer (IIP by homogeneous polymerization and its use in solid-phase to extract and preconcentrate zinc ions. Under optimal conditions (pH 5.0, preconcentration flow rate of 12.0 mL min-1, and eluted with 1.0 mol L-1 HNO3 this procedure allows the determination of zinc with an enrichment factor of 10.2, and with limits of detection and quantification of 1.5 and 5.0 µg L-1, respectively. The accuracy of our results was confirmed by analysis of tap water and certified reference materials: NIST 1570a (Spinach leaves and NIST 1515 (Apple leaves.

  4. Heat-assisted aqueous extraction of rice flour for arsenic speciation analysis.

    Science.gov (United States)

    Narukawa, Tomohiro; Chiba, Koichi

    2010-07-28

    A versatile heat-assisted pretreatment aqueous extraction method for the analysis of arsenic species in rice was developed. Rice flour certified reference materials NIST SRM1568a and NMIJ CRM 7503-a and a flour made from polished rice were used as samples, and HPLC-ICP-MS was employed for the determination of arsenic species. Arsenite [As(III)], arsenate [As(V)], monomethylarsonic acid (MMAA) and dimethylarsinic acid (DMAA) were detected in NIST SRM, and As(III), As(V) and DMAA were found in NMIJ CRM and the prepared polished rice flour. The sums of the concentrations of all species in each rice flour sample were 97-102% of the total arsenic concentration in each sample.

  5. The Triple Axis and SPINS Spectrometers.

    Science.gov (United States)

    Trevino, S F

    1993-01-01

    In this paper are described the triple axis and spin polarized inelastic neutron scattering (SPINS) spectrometers which are installed at the NIST Cold Neutron Research Facility (CNRF). The general principle of operation of these two instruments is described in sufficient detail to allow the reader to make an informed decision as to their usefulness for his needs. However, it is the intention of the staff at the CNRF to provide the expert resources for their efficient use in any given situation. Thus, this work is not intended as a user manual but rather as a guide into the range of applicability of the two instruments.

  6. Small genomes: New initiatives in mapping and sequencing. Workshop summary report

    Energy Technology Data Exchange (ETDEWEB)

    McKenney, K. [National Inst. of Standards and Technology, Gaithersburg, MD (United States). Biotechnology Div.; Robb, F. [Univ. of Maryland Biotechnology Inst., Baltimore, MD (United States). Center of Marine Biotechnology

    1993-12-31

    The workshop was held 5--7 July 1993 at the Center for Advanced Research in Biotechnology (CARB) and hosted by the University of Maryland Biotechnology Institute (UMBI) and the National Institute of Standards and Technology (NIST). The objective of this workshop was to bring together individuals interested in DNA technologies and to determine the impact of these current and potential improvements of the speed and cost-effectiveness of mapping and sequencing on the planning of future small genome projects. A major goal of the workshop was to spur the collaboration of more diverse groups of scientists working on this topic, and to minimize competitiveness as an inhibitory factor to progress.

  7. Multiconfiguration Dirac-Hartree-Fock calculations of energy levels and radiative rates of Fe VII

    Science.gov (United States)

    Li, Yang; Xu, Xiaokai; Li, Bowen; Jönsson, Per; Chen, Ximeng

    2018-06-01

    Detailed calculations are performed for 134 fine-structure levels of the 3p63d2, 3p63d4s, 3p53d3 and 3p63d4p configurations in Fe VII using the multiconfiguration Dirac-Hartree-Fock (MCDHF) and relativistic configuration interaction (RCI) methods. Important electron correlation effects are systematically accounted for through active space (AS) expansions. Our results compare well with experimental measurements, emphasizing the importance of a careful treatment of electron correlation, and provide some missing data in the NIST atomic database. The data obtained are expected to be useful in astrophysical applications, particularly for the research of the solar coronal plasma.

  8. Researcher / Researched: Repositioning Research Paradigms

    Science.gov (United States)

    Meerwald, Agnes May Lin

    2013-01-01

    "Researcher / Researched" calls for a complementary research methodology by proposing autoethnography as both a method and text that crosses the boundaries of conventional and alternative methodologies in higher education. Autoethnography rearticulates the researcher / researched positions by blurring the boundary between them. This…

  9. Aperture area measurement facility

    Data.gov (United States)

    Federal Laboratory Consortium — NIST has established an absolute aperture area measurement facility for circular and near-circular apertures use in radiometric instruments. The facility consists of...

  10. Photovoltaic Characterization Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — NIST's PV characterization laboratory is used to measure the electrical performance and opto-electronic properties of solar cells and modules. This facility consists...

  11. Chemical characterization of diets consumed in the COSEAS restaurant, by neutron activation analysis

    International Nuclear Information System (INIS)

    Favaro, Deborah I.T.; Chioccola, Gabriella S.; Bortoli, Maritsa C.; Cozzolino, Silvia M.F.

    2005-01-01

    This study presents the results of chemical characterization of meals (lunch) offered by COSEAS/USP-SP restaurant, during 5 non consecutive days. These meals were collected in triplicate, in the same way they are offered to the users, being freeze-dried and prepared for chemical analysis. In the total, 15 samples were collected. The proximate composition was determined by using the standard methodologies according to AOAC (1995). The contents of some micronutrients (Ca, Fe, K, Na, Se and Zn) were determined by instrumental neutron activation analysis. The methodology validation was performed by certified reference materials analyses: Oyster Tissue (NIST SRM 1566 b ), Orchard Leaves (NIST SRM 1541) and Peach Leaves (NIST SRM 1547). >From concentration results the daily intake of each micronutrient was calculated considering this meal as 40% of the total daily intake and the values were compared to the new dietary recommendations of micronutrients (Dietary Reference Intakes-DRIs, Institute of Medicine, USA), for the women in the life stage from 19 to 30 years. Comparing the average values found with the recommended values, it was verified that macronutrients and Fe, Se and Zn micronutrients reached the values set by new DRIs. For Ca and K the daily intake was inadequate and Na, exceeded the recommended value. (author)

  12. Chemical characterization of diets consumed in the COSEAS restaurant, by neutron activation analysis; Caracterizacao quimica de dietas consumidas no restaurante do COSEAS/USP-SP, por ativacao neutronica

    Energy Technology Data Exchange (ETDEWEB)

    Favaro, Deborah I.T. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil). Lab. de Analise por Ativacao Neutronica]. E-mail: defavaro@ipen.br; Chioccola, Gabriella S.; Bortoli, Maritsa C.; Cozzolino, Silvia M.F. [Sao Paulo Univ., SP (Brazil). Faculdade de Ciencias Farmaceuticas. Lab. de Alimentos e Nutricao Experimental]. E-mail: gabich@usp.br

    2005-07-01

    This study presents the results of chemical characterization of meals (lunch) offered by COSEAS/USP-SP restaurant, during 5 non consecutive days. These meals were collected in triplicate, in the same way they are offered to the users, being freeze-dried and prepared for chemical analysis. In the total, 15 samples were collected. The proximate composition was determined by using the standard methodologies according to AOAC (1995). The contents of some micronutrients (Ca, Fe, K, Na, Se and Zn) were determined by instrumental neutron activation analysis. The methodology validation was performed by certified reference materials analyses: Oyster Tissue (NIST SRM 1566{sup b}), Orchard Leaves (NIST SRM 1541) and Peach Leaves (NIST SRM 1547). >From concentration results the daily intake of each micronutrient was calculated considering this meal as 40% of the total daily intake and the values were compared to the new dietary recommendations of micronutrients (Dietary Reference Intakes-DRIs, Institute of Medicine, USA), for the women in the life stage from 19 to 30 years. Comparing the average values found with the recommended values, it was verified that macronutrients and Fe, Se and Zn micronutrients reached the values set by new DRIs. For Ca and K the daily intake was inadequate and Na, exceeded the recommended value. (author)

  13. 76 FR 2081 - Submission for OMB Review; Comment Request

    Science.gov (United States)

    2011-01-12

    ... careers in science, technology, engineering, and mathematics (STEM) fields. To receive funding, nominated... received, NIST will announce competitions under these two programs in February 2011, applications will be...

  14. 78 FR 67118 - Notice of Limited, Program-Wide, Public Interest Waivers of Section 1605(a) (Buy American...

    Science.gov (United States)

    2013-11-08

    ... diligence. Requiring NIST construction grant recipients to expend substantial resources to comply with Buy... life safety concerns. Further, while system function and interoperability is of primary public interest...

  15. Standard Firebrand Generator

    Data.gov (United States)

    Federal Laboratory Consortium — This apparatus, developed at EL, has been constructed to generate a controlled and repeatable size and mass distribution of glowing firebrands. The purpose of NIST...

  16. Unmanned Aerial Vehicles for Wildland-Urban Interface Fires

    Data.gov (United States)

    Federal Laboratory Consortium — NIST with US Forest Service (USFS) have invested in the development of instrument packages and measurement science to enable the successful scientific use of these...

  17. Researching research

    DEFF Research Database (Denmark)

    Pais, Alexandre; Valero, Paola

    2012-01-01

    We discuss contemporary theories in mathematics education in order to do research on research. Our strategy consists of analysing discursively and ideologically recent key publications addressing the role of theory in mathematics education research. We examine how the field fabricates its object...... of research by deploying Foucault’s notion of bio-politics - mainly to address the object “learning” - and Žižek’s ideology critique - to address the object “mathematics”. These theories, which have already been used in the field to research teaching and learning, have a great potential to contribute...... to a reflexivity of research on its discourses and effects. Furthermore, they enable us to present a clear distinction between what has been called the sociopolitical turn in mathematics education research and what we call a positioning of mathematics education (research) practices in the Political....

  18. Micro-Combined Heat and Power Device Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — NIST has developed a test facility for micro-combined heat and power (micro-CHP) devices to measure their performance over a range of different operating strategies...

  19. Color and appearance metrology facility

    Data.gov (United States)

    Federal Laboratory Consortium — The NIST Physical Measurement Laboratory has established the color and appearance metrology facility to support calibration services for 0°/45° colored samples, 20°,...

  20. Ozone Standard Reference Photometer

    Data.gov (United States)

    Federal Laboratory Consortium — The Standard Reference Photometer (SRP) Program began in the early 1980s as collaboration between NIST and the U.S. Environmental Protection Agency (EPA) to design,...

  1. k{sub 0}-INAA method at the pneumatic station of the IEA-R1 nuclear research reactor. Application to geological samples

    Energy Technology Data Exchange (ETDEWEB)

    Mariano, Davi B.; Figueiredo, Ana Maria G.; Semmler, Renato, E-mail: davimariano@usp.br, E-mail: anamaria@ipen.br, E-mail: rsemmler@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    There is a significant number of analytically important elements, when geological samples are concerned, whose activation products are short-lived (seconds to minutes) or medium-lived radioisotopes (minutes to hours). As part of the process of implementation of the k{sub 0}-INAA standardization method at the Neutron Activation Laboratory (LAN-IPEN), Sao Paulo, Brazil, this study presents the results obtained for the analysis of short and medium-lived nuclides in geological samples by k{sub 0}-INAA using the program k{sub 0}-IAEA, provided by The International Atomic Energy Agency (IAEA). The elements Al, Dy, Eu, Na, K, Mn, Mg, Sr, V and Ti were determined with respect to gold ({sup 197}Au) using the pneumatic station facility of the IEA-R1 5 MW swimming pool nuclear research reactor, Sao Paulo. Characterization of the pneumatic station was carried out by using the -bare triple-monitor- method with {sup 197}Au-{sup 96}Zr-{sup 94}Zr. The Certified Reference Material IRMM-530R Al-0,1% Au alloy, high purity zirconium, Ni and Lu comparators were irradiated. The efficiency curves of the gamma-ray spectrometer used were determined by measuring calibrated radioactive sources at the usually utilized counting geometries. The method was validated by analyzing the reference materials basalt BE-N (IWG-GIT), basalt JB- 1 (GSJ), andesite AGV-1 (USGS), granite GS-N (IWG-GIT), SOIL-7 (IAEA) and sediment Buffalo River Sediment (NIST-BRS-8704), which represent different geological matrices. The concentration results obtained agreed with certified, reference and recommended values, showing relative errors less than 10% for most elements. (author)

  2. Muslimská rodina v Afghánistánu

    OpenAIRE

    Kmochová, Eva

    2010-01-01

    This documentation deals with a life of Afghan family which is much influenced by Islam religion and geographical, economical, political or law and many others aspects. It describes a position of woman and child in the context of family hierarchy and also the problems of a rural big-family. It explains the reasons of a woman's role in the family and than particular and important phases in Afghan life. Concretely, it deals with a child birth, the differences in upbringing between daughters and...

  3. Characterization of the NIST shellfish Standard Reference Material 4358

    International Nuclear Information System (INIS)

    Nour, S.; Inn, K.G.W.; Filliben, J.; Gaast van der, H.; Men, L.C.; Calmet, D.; Altzitzoglou, T.; Povinec, P.; Takata, Y.; Wisdom, M.

    2013-01-01

    A new shellfish Standard Reference Material 4358 was developed by the National Institute of Standards and Technology through an international interlaboratory comparison that involved twelve laboratories-participants from nine countries. The results from the participants were statistically evaluated, and the most robust certified values were based on the median of laboratories’ reported means and the uncertainties derived using the bootstrap method. Massic activity certified values were established for fourteen radionuclides, five activity ratios, and informational massic activity values for eight more radionuclides and two activity ratios. (author)

  4. Geant4 simulations of NIST beam neutron lifetime experiment

    Science.gov (United States)

    Valete, Daniel; Crawford, Bret; BL2 Collaboration Collaboration

    2017-09-01

    A free neutron is unstable and its decay is described by the Standard Model as the transformation of a down quark into an up quark through the weak interaction. Precise measurements of the neutron lifetime test the validity of the theory of the weak interaction and provide useful information for the predictions of the theory of Big Bang nucleosynthesis of the primordial helium abundance in the universe and the number of different types of light neutrinos Nν. The predominant experimental methods for determination of the neutron lifetime are commonly called `beam' and `bottle' methods, and the most recent uses of each method do not agree with each other within their stated uncertainties. An improved experiment of the beam technique, which uses magnetic and electric fields to trap and guide the decay protons of a beam of cold neutrons to a detector, is in progress at the National Institute of Standards and Technology, Gaithersburg, MD with a precision goal of 0.1. I acknowledge the support of the Cross-Diciplinary Institute at Gettysburg College.

  5. Polarized 3He Neutron Spin Filters

    Energy Technology Data Exchange (ETDEWEB)

    Sno, William Michael [Indiana Univ., Bloomington, IN (United States)

    2016-01-12

    The goal of this grant to Indiana University and subcontractors at Hamilton College and Wisconsin and the associated Interagency Agreement with NIST was to extend the technique of polarized neutron scattering by the development and application of polarized 3He-based neutron spin filters. This effort was blessed with long-term support from the DOE Office of Science, which started in 2003 and continued until the end of a final no-cost extension of the last 3-year period of support in 2013. The steady support from the DOE Office of Science for this long-term development project was essential to its eventual success. Further 3He neutron spin filter development is now sited at NIST and ORNL.

  6. NAA characterization of the new Bovine Liver SRM

    International Nuclear Information System (INIS)

    Zeisler, R.; Mackey, E.A.; Spatz, R.O.; Greenberg, R.R.; James, W.D.

    2008-01-01

    The National Institute of Standards and Technology (NIST) is preparing a freeze-dried powdered bovine liver tissue Standard Reference Material (SRM) to replace SRM 1577b Bovine Liver as the stock of this material was exhausted during 2006. Like the original SRM 1577 issued in 1972, this renewal focuses on the key elements for diagnostic, nutritional, and toxicological measurements that are important to medical, veterinary, and environmental sciences investigations. NIST's approach for value assignment included extensive characterization by neutron activation analysis (NAA). Difficulties in the determination of some elements present at very low levels were overcome by use of radiochemical separations. Twentyone elements were characterized in SRM 1577c by NAA. The previous materials, SRM 1577 and 1577b, served as quality control. (author)

  7. Ultra-micro trace element contents in spices from Sri Lanka

    International Nuclear Information System (INIS)

    Chery, C.C.; Herremans, S.; Van Lierde, V.; Vanhaecke, F.; Jasekera, R.

    2008-01-01

    Spices were analyzed by ICP-MS for determination of the ultra-micro trace elements in the human adult, Bi, Cd, Co, Ni, Pd, Pt, Se, Sn, Te, Tl, to complement previous results obtained by INAA and by EDXRF. The spices, originating from Sri Lanka, were curry, chilli powder and turmeric powders, coriander, cinnamon, black pepper, fennel, rampeh and curry leaves, and cumin. The analytical procedure was validated by analyzing the certified reference materials NIST SRM 1572 Citrus Leaves and NIST SRM 1573 Tomato Leaves. The results indicate that spices may contribute well to the daily optimal uptake of nutrients of a human adult. The adequacy of spices as a reference material with certified ultra micro trace elements is suggested. (author)

  8. Hydrodynamics of Normal Atomic Gases with Spin-orbit Coupling.

    Science.gov (United States)

    Hou, Yan-Hua; Yu, Zhenhua

    2015-10-20

    Successful realization of spin-orbit coupling in atomic gases by the NIST scheme opens the prospect of studying the effects of spin-orbit coupling on many-body physics in an unprecedentedly controllable way. Here we derive the linearized hydrodynamic equations for the normal atomic gases of the spin-orbit coupling by the NIST scheme with zero detuning. We show that the hydrodynamics of the system crucially depends on the momentum susceptibilities which can be modified by the spin-orbit coupling. We reveal the effects of the spin-orbit coupling on the sound velocities and the dipole mode frequency of the gases by applying our formalism to the ideal Fermi gas. We also discuss the generalization of our results to other situations.

  9. The needs for brachytherapy source calibrations in the United States

    International Nuclear Information System (INIS)

    Coursey, B.M.; Goodman, L.J.; Hoppes, D.D.; Loevinger, R.; McLaughlin, W.L.; Soares, C.G.; Weaver, J.T.

    1992-01-01

    Brachytherapy sources of beta and gamma radiation ('brachy' is from the Greek, meaning 'near') have a long history of use in interstitial, intracavitary, intraluminal, and ocular radiation therapy. In the past the US national standards for these sources were often specified in activity or milligram radium equivalent. With the introduction of new radionuclide sources to replace radium, source strength calibrations are now expressed as air kerma rate at a meter. In this paper, we review the NIST standards for brachytherapy sources, list some of the common radionuclides and source encapsulations in use in the US radiology community, and describe the latest NIST work, in collaboration with several US medical institutions, on a method of two- and three-dimensional dose mapping of brachytherapy sources using radiochromic films. (orig.)

  10. Neutron activation analysis with pre- and post-irradiation chemical separation for the value assignments of Al, V, and Ni in the new bovine liver SRM 1577C

    International Nuclear Information System (INIS)

    Zeisler, R.; Tomlin, B.E.; Murphy, K.E.

    2009-01-01

    Instrumental neutron activation analysis as carried out at the National Institute of Standards and Technology (NIST) is inadequate for determining Al, Ni, and V at the levels found in the newly prepared Standard Reference Material R (SRM) 1577c Bovine Liver. To overcome shortcomings in the value assignment, the authors initiated a cooperative approach using NAA with previously established chemical separation procedures and with significantly different neutron energy spectra to determine Al and V with pre-irradiation separation of the elements at NIST, and V and Ni with post-irradiation separation at the Nuclear Physics Institute Rez. The determinations were confirmed with the analyses of several SRMs. The work supported the certification of mass fraction values for V and Ni in SRM 1577c. (author)

  11. Comparison Study on Low Energy Physics Model of GEANT4

    International Nuclear Information System (INIS)

    Park, So Hyun; Jung, Won Gyun; Suh, Tae Suk

    2010-01-01

    The Geant4 simulation toolkit provides improved or renewed physics model according to the version. The latest Geant4.9.3 which has been recoded by developers applies inserted Livermore data and renewed physics model to the low energy electromagnetic physics model. And also, Geant4.9.3 improved the physics factors by modified code. In this study, the stopping power and CSDA(Continuously Slowing Down Approximation) range data of electron or particles were acquired in various material and then, these data were compared with NIST(National Institute of Standards and Technology) data. Through comparison between data of Geant4 simulation and NIST, the improvement of physics model on low energy electromagnetic of Geant4.9.3 was evaluated by comparing the Geant4.9.2

  12. 76 FR 16609 - Proposed Information Collection; Comment Request; Identification of Human Cell Lines Project

    Science.gov (United States)

    2011-03-24

    ... differentiate among cell lines, as described in Designation: ASN-0002 Authentication of Human Cell Lines... NIST (contact information above). III. Data OMB Control Number: None. Form Number: None. Type of Review...

  13. Field Demonstration of the Ground to Space Laser Calibration: Illumination of NASA’s Earth Observing Sensors

    Data.gov (United States)

    National Aeronautics and Space Administration — We will capitalize on a NASA-NIST partnership to conduct a test illumination of an existing radiometric sensor on orbit. This preliminary demonstration would target...

  14. EPA’s Hg Gas Traceability Approach for Source Emissions Measurement and Monitoring

    Science.gov (United States)

    Solicited presentation (special topic) at the International Conference on Mercury as a Global Pollutant on how EPA establishes the NIST traceability of reference materials used to support regulatory mercury emissions measurements.

  15. Optimization of the Photon Response for a LiF Thermoluminescent Dosimeter

    National Research Council Canada - National Science Library

    Carnell, Robert

    1998-01-01

    .... These results correlated with experimental data from NIST to within 20%. In order to increase the accuracy of the model, energy deposition calculations were made using the MCNP particle transport program...

  16. Robust Frequency Combs and Lasers for Optical Clocks and Sensing, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Vescent Photonics proposes to bring an environmentally robust, compact, high fidelity frequency comb to the commercial market. This will be comb based on a NIST...

  17. Accuracy of magnetic resonance based susceptibility measurements

    Science.gov (United States)

    Erdevig, Hannah E.; Russek, Stephen E.; Carnicka, Slavka; Stupic, Karl F.; Keenan, Kathryn E.

    2017-05-01

    Magnetic Resonance Imaging (MRI) is increasingly used to map the magnetic susceptibility of tissue to identify cerebral microbleeds associated with traumatic brain injury and pathological iron deposits associated with neurodegenerative diseases such as Parkinson's and Alzheimer's disease. Accurate measurements of susceptibility are important for determining oxygen and iron content in blood vessels and brain tissue for use in noninvasive clinical diagnosis and treatment assessments. Induced magnetic fields with amplitude on the order of 100 nT, can be detected using MRI phase images. The induced field distributions can then be inverted to obtain quantitative susceptibility maps. The focus of this research was to determine the accuracy of MRI-based susceptibility measurements using simple phantom geometries and to compare the susceptibility measurements with magnetometry measurements where SI-traceable standards are available. The susceptibilities of paramagnetic salt solutions in cylindrical containers were measured as a function of orientation relative to the static MRI field. The observed induced fields as a function of orientation of the cylinder were in good agreement with simple models. The MRI susceptibility measurements were compared with SQUID magnetometry using NIST-traceable standards. MRI can accurately measure relative magnetic susceptibilities while SQUID magnetometry measures absolute magnetic susceptibility. Given the accuracy of moment measurements of tissue mimicking samples, and the need to look at small differences in tissue properties, the use of existing NIST standard reference materials to calibrate MRI reference structures is problematic and better reference materials are required.

  18. Standardisation and use of westcott formalism for the determination of trace elements in some Ghanaian herbal medicines complemented by atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Ayivor, J. E.

    2009-02-01

    The α - shape factor of the inner and outer irradiation sites of the Ghana Research Reactor-1 (GHARR-1) was determined using the dual monitor cadmium ratio method for the purpose of application of Westcott Formalism standardisation of the k o NAA. The results obtained are -0.1053 for the inner irradiation site (channel 1) and -0.0202 for the outer irradiation site (channel 6). The modified spectral index r (α) √ (T n )/T o ) and g (T n ) factors were also evaluated. From the irradiation of 176 Lu, the g Lu (T n ) was also evaluated to monitor the neutron temperature for the inner and outer irradiation sites yielding 1.800 and 1.704 respectively. For its application in NAA, NIST 1547, NIST 1571 and IAEA- V- 10 hay powder were analysed for the validation of the method. The measured values were found to be in good agreement with the certified values; generally within ± 10%. Thirteen plant medicines used for the treatment of various diseases were analysed using k o NAA for Al, As, Br, Cd, Cl, Cu, K, Mg, Mn, Mo, Na and V. The method was complimented by the AAS methods for the determination of Ba, Ca, Co, Cr, Fe, Li, Ni, Pb, Sb and Sn. The concentrations of elements were within the recommended daily allowances or maximum permissible levels posing no adverse effects on human health. (au)

  19. Evaluation and compilation of DOE waste package test data

    International Nuclear Information System (INIS)

    Interrante, C.G.; Fraker, A.C.; Escalante, E.

    1991-12-01

    This report summarizes evaluations by the National Institute of Standards and Technology (NIST) of Department of Energy (DOE) activities on waste packages designed for containment of radioactive high-level nuclear waste (HLW) for the six-month period, February through July 1989. This includes reviews of related materials research and plans, information on the Yucca Mountain, Nevada disposal site activities, and other information regarding supporting research and special assistance. Outlines for planned interpretative reports on the topics of aqueous corrosion of copper, mechanisms of stress corrosion cracking and internal failure modes of Zircaloy cladding are included. For the publications reviewed during this reporting period, short discussions are given to supplement the completed reviews and evaluations. Included in this report is an overall review of a 1984 report on glass leaching mechanisms, as well as reviews for each of the seven chapters of this report

  20. Biological and environmental reference materials in CENAM.

    Science.gov (United States)

    Arvizu-Torres, R; Perez-Castorena, A; Salas-Tellez, J A; Mitani-Nakanishi, Y

    2001-06-01

    Since 1994, when the NIST/NOAA Quality Assurance Program in Chemical Measurements was discussed in Queretaro, CENAM, the National Measurement Institute (NMI) of Mexico, has become involved in the development of reference materials. In the field of biological and environmental reference materials, in particular, the NORAMET collaboration program with NIST and NRC, and the North-American Environmental Cooperation signed among three free-trade treaty organizations, have greatly helped the development of the materials metrology program in the newly established CENAM. This paper describes some particularly significant efforts of CENAM in the development of biological and environmental reference materials, on the basis of inter-comparison studies organized with local and governmental environmental agencies of Mexico. In the field of water pollution CENAM has developed a practical proficiency testing (PT) scheme for field laboratories, as a part of registration by local government in the metropolitan area, according to the Mexican Ecological Regulation. The results from these eight PTs in the last 5 years have demonstrated that this scheme has helped ensure the reliability of analytical capability of more than 50 field laboratories in three states, Mexico, D.F., and the States of Mexico and Queretaro. Similar experience has been obtained for more than 70 service units of stack emission measurements in the three states in 1998 and 1999, as a result of the design of a PT scheme for reference gas mixtures. This PT scheme has been accomplished successfully by 30 analytical laboratories who provide monitoring services and perform research on toxic substances (Hg, methylmercury, PCB, etc.) in Mexico. To support these activities, reference samples have been produced through the NIST SRMs, and efforts have been made to increase CENAM's capability in the preparation of primary reference materials in spectrometric solutions and gas mixtures. Collaboration among NMIs has also

  1. 75 FR 9392 - National Institute of Standards and Technology Construction Grant Program

    Science.gov (United States)

    2010-03-02

    ...., table top equipment, portable air conditioners, etc. Equipment that is an integral part of the building... of the legislative history, NIST publishes this notice to set forth the program goals and objectives...

  2. Determination of trace elements in Pre-Hispanic ceramics from Chile's Central Zone using instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Andonie, O; Munoz, L; Kohnnenkamp, I; Falabella, F

    2000-01-01

    The determination of the element composition in archaeological ceramics is an often unexplored potential, that could provide a unique set of data to verify regional economic and socio-political hypotheses. By chemically defining the elements in these materials, their manufacturing and production centers may be identified, as well as the territorial and social organization of the peoples. Appropriate analytical methodologies for this type of research are limited since there are strict requirements with reference to precision, sensitivity and detection limits, all characteristics that the activation analysis technique provides. The Chilean Nuclear Energy Commission, the University of Chile, the Smithsonian Institution and the International Atomic Energy Agency developed together a cooperative interregional project to promote interdisciplinary research, to resolve archaeological problems and to develop a new application for a nuclear analytical technique. Until this work was undertaken, no systematic studies of trace elements in archaeological ceramics had been done in Chile using the technique of Instrumental Neutron Activation Analysis (INAA). This analytical technique was used in this research to chemically characterize archaeological pieces with the sensitivity, precision and accuracy needed to be able to work with mathematical models that can or cannot establish relationships between the different samples. Protocols were defined first for preparing the pottery samples in order to generate representative samples that could be analyzed by INAA. The homogeneity in preparing the samples used was defined using a group of elements that could be determined by INAA with a precision under 2%. A group of 18 elements was selected and an analytical test procedure was planned that included the type of packaging for the irradiation, the irradiation times, decline and count, the standards to be used and the type of monitor for correcting the neutron flow. The methodology used

  3. Experimental half-life determination of 176Lu

    International Nuclear Information System (INIS)

    Kossert, Karsten; Jörg, Gerhard; Gostomski, Christoph Lierse v.

    2013-01-01

    The half-life of the naturally occurring long-lived rare earth isotope 176 Lu was determined by a combination of highly sophisticated experimental procedures in order to further improve the reliability and the precision of literature data. The amount of lutetium in the samples was determined by inductively coupled plasma optical emission spectrometry (ICP-OES) using a NIST reference standard. The isotopic ratio N( 176 Lu)/N(Lu) in the samples was measured by means of inductively coupled plasma high resolution mass spectrometry (ICP-HRMS). The activity divided by the mass of Lu was determined by applying liquid scintillation (LS) counting. The LS counting efficiency of the beta/gamma emitter 176 Lu was determined with the CIEMAT/NIST efficiency tracing technique with low uncertainty. The influences of colour quenching and background effects are discussed in this paper. The half-life was found to be 3.640(35)×10 10 y. The result is in good agreement with other evaluations and the relative standard uncertainty of 0.95% is among the lowest of previously published data. - Highlights: • The half-life of 176 Lu was determined by ICP-OES, ICP-HRMS and LSC. • The LSC efficiency was determined with the CIEMAT/NIST method. • The half-life was found to be 3.640(35)×10 10 y

  4. Spectral measurements in critical assemblies: MCNP specifications and calculated results

    Energy Technology Data Exchange (ETDEWEB)

    Stephanie C. Frankle; Judith F. Briesmeister

    1999-12-01

    Recently, a suite of 86 criticality benchmarks for the Monte Carlo N-Particle (MCNP) transport code was developed, and the results of testing the ENDF/B-V and ENDF/B-VI data (through Release 2) were published. In addition to the standard k{sub eff} measurements, other experimental measurements were performed on a number of these benchmark assemblies. In particular, the Cross Section Evaluation Working Group (CSEWG) specifications contain experimental data for neutron leakage and central-flux measurements, central-fission ratio measurements, and activation ratio measurements. Additionally, there exists another set of fission reaction-rate measurements performed at the National Institute of Standards and Technology (NIST) utilizing a {sup 252}Cf source. This report will describe the leakage and central-flux measurements and show a comparison of experimental data to MCNP simulations performed using the ENDF/B-V and B-VI (Release 2) data libraries. Central-fission and activation reaction-rate measurements will be described, and the comparison of experimental data to MCNP simulations using available data libraries for each reaction of interest will be presented. Finally, the NIST fission reaction-rate measurements will be described. A comparison of MCNP results published previously with the current MCNP simulations will be presented for the NIST measurements, and a comparison of the current MCNP simulations to the experimental measurements will be presented.

  5. Spectral measurements in critical assemblies: MCNP specifications and calculated results

    International Nuclear Information System (INIS)

    Frankle, Stephanie C.; Briesmeister, Judith F.

    1999-01-01

    Recently, a suite of 86 criticality benchmarks for the Monte Carlo N-Particle (MCNP) transport code was developed, and the results of testing the ENDF/B-V and ENDF/B-VI data (through Release 2) were published. In addition to the standard k eff measurements, other experimental measurements were performed on a number of these benchmark assemblies. In particular, the Cross Section Evaluation Working Group (CSEWG) specifications contain experimental data for neutron leakage and central-flux measurements, central-fission ratio measurements, and activation ratio measurements. Additionally, there exists another set of fission reaction-rate measurements performed at the National Institute of Standards and Technology (NIST) utilizing a 252 Cf source. This report will describe the leakage and central-flux measurements and show a comparison of experimental data to MCNP simulations performed using the ENDF/B-V and B-VI (Release 2) data libraries. Central-fission and activation reaction-rate measurements will be described, and the comparison of experimental data to MCNP simulations using available data libraries for each reaction of interest will be presented. Finally, the NIST fission reaction-rate measurements will be described. A comparison of MCNP results published previously with the current MCNP simulations will be presented for the NIST measurements, and a comparison of the current MCNP simulations to the experimental measurements will be presented

  6. LA-ICP-MS of magnetite: Methods and reference materials

    Science.gov (United States)

    Nadoll, P.; Koenig, A.E.

    2011-01-01

    Magnetite (Fe3O4) is a common accessory mineral in many geologic settings. Its variable geochemistry makes it a powerful petrogenetic indicator. Electron microprobe (EMPA) analyses are commonly used to examine major and minor element contents in magnetite. Laser ablation ICP-MS (LA-ICP-MS) is applicable to trace element analyses of magnetite but has not been widely employed to examine compositional variations. We tested the applicability of the NIST SRM 610, the USGS GSE-1G, and the NIST SRM 2782 reference materials (RMs) as external standards and developed a reliable method for LA-ICP-MS analysis of magnetite. LA-ICP-MS analyses were carried out on well characterized magnetite samples with a 193 nm, Excimer, ArF LA system. Although matrix-matched RMs are sometimes important for calibration and normalization of LA-ICP-MS data, we demonstrate that glass RMs can produce accurate results for LA-ICP-MS analyses of magnetite. Cross-comparison between the NIST SRM 610 and USGS GSE-1G indicates good agreement for magnetite minor and trace element data calibrated with either of these RMs. Many elements show a sufficiently good match between the LA-ICP-MS and the EMPA data; for example, Ti and V show a close to linear relationship with correlation coefficients, R2 of 0.79 and 0.85 respectively. ?? 2011 The Royal Society of Chemistry.

  7. Double pulse laser induced breakdown spectroscopy: Experimental study of lead emission intensity dependence on the wavelengths and sample matrix

    Energy Technology Data Exchange (ETDEWEB)

    Piscitelli S, V; Martinez L, M A; Fernandez C, A J [Laboratorio de Espectroscopia Laser, Escuela de Quimica, Facultad de Ciencias, Universidad Central de Venezuela, Caracas, DC 1020 (Venezuela, Bolivarian Republic of); Gonzalez, J J; Mao, X L [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Russo, R.E. [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States)], E-mail: RERusso@lbl.gov

    2009-02-15

    Lead (Pb) emission intensity (atomic line 405.78 nm) dependence on the sample matrix (metal alloy) was studied by means of collinear double pulse (DP)-laser induced breakdown spectroscopy (LIBS). The measurement of the emission intensity produced by three different wavelength combinations (i.e. I:532 nm-II:1064 nm, I:532 nm-II:532 nm, and I:532 nm-II:355 nm) from three series of standard reference materials showed that the lead atomic line 405.78 nm emission intensity was dependent on the sample matrix for all the combination of wavelengths, however reduced dependency was found for the wavelength combination I:532 nm-II:355 nm. Two series of standard reference materials from the National Institute of Standards and Technology (NIST) and one series from the British Chemical Standards (BCS) were used for these experiments. Calibration curves for lead ablated from NIST 626-630 ('Zn{sub 95}Al{sub 4}Cu{sub 1}') provided higher sensitivity (slope) than those calibration curves produced from NIST 1737-1741 ('Zn{sub 99.5}Al{sub 0.5}') and with the series BCS 551-556 ('Cu{sub 87}Sn{sub 11}'). Similar trends between lead emission intensity (calibration curve sensitivities) and reported variations in plasma temperatures caused by the differing ionization potentials of the major and minor elements in these samples were established.

  8. Microcalorimeter Detector

    Data.gov (United States)

    Federal Laboratory Consortium — The NIST transition edge sensor microcalorimeter is energy dispersive x-ray spectrometer capable of ~5 eV resolution over a range of energies from hundreds to eV to...

  9. Dgroup: DG00834 [KEGG MEDICUS

    Lifescience Database Archive (English)

    Full Text Available nist ... DG01964 ... Ergot alkaloid ... DG01982 ... Antimigraine, ergot alkaloid Cyp substrate ... DG01633 ... CYP3A substrate... ATC code: N02CA02 Antimigraine, Vasoconstrictor, Serotonin receptor agonist/anta

  10. 76 FR 27016 - Evaluating Test Procedures for Voting Systems

    Science.gov (United States)

    2011-05-10

    ... Understanding. Comparative information (e.g., testing results from unidentified machine A, B, and C) may be... and deployment of the equipment. NIST will pay all shipping costs except those not permitted by law...

  11. Researcher-researched relationship in qualitative research: Shifts in positions and researcher vulnerability.

    Science.gov (United States)

    Råheim, Målfrid; Magnussen, Liv Heide; Sekse, Ragnhild Johanne Tveit; Lunde, Åshild; Jacobsen, Torild; Blystad, Astrid

    2016-01-01

    The researcher role is highly debated in qualitative research. This article concerns the researcher-researched relationship. A group of health science researchers anchored in various qualitative research traditions gathered in reflective group discussions over a period of two years. Efforts to establish an anti-authoritarian relationship between researcher and researched, negotiation of who actually "rules" the research agenda, and experiences of shifts in "inferior" and "superior" knowledge positions emerged as central and intertwined themes throughout the discussions. The dual role as both insider and outsider, characteristic of qualitative approaches, seemed to lead to power relations and researcher vulnerability which manifested in tangible ways. Shifting positions and vulnerability surfaced in various ways in the projects. They nonetheless indicated a number of similar experiences which can shed light on the researcher-researched relationship. These issues could benefit from further discussion in the qualitative health research literature.

  12. APPLICATION OF NEUTRON ACTIVATION ANALYSIS IN CHARACTERIZATION OF ENVIRONMENTAL SRM SAMPLES

    Directory of Open Access Journals (Sweden)

    Diah Dwiana Lestiani

    2010-06-01

    Full Text Available Neutron activation analysis (NAA is a nuclear technique that is excellent, multi-elemental, sensitive and has limit detection up to nanogram level. The application of NAA in analysis of Standard Reference Material (SRM National Institute of Standard Technology (NIST 1633b Coal Fly Ash and SRM NIST 1646a Estuarine Sediment was carried out for NAA laboratory inter-comparison program. The samples were distributed by Technology Centre for Nuclear Industry Material, National Nuclear Energy Agency as a coordinator of the inter-comparison program. The samples were irradiated in rabbit facility of G.A. Siwabessy reactor with neutron flux ~ 1013 n.cm-2.s-1, and counted with HPGe spectrometry gamma detector. Several trace elements in these samples were detected. The concentration of Al, Mg, K, Na and Ti in SRM NIST 1633b were 15.11, 7.35, 2.09, 0.192 and 0.756% respectively and the concentration of As, Cr, Mn, Se, V, Sb, Co, Cs, La, Sc and Sm were 137.0, 195.6, 129.4, 9.61, 305.8, 5.45, 56.2, 11.18, 83.73, 41.1 and 19.13 mg/kg respectively. The analysis result in SRM NIST 1646a of the concentration of Al and Na were 2.15 and 0.70% and the concentration of As, Cr, Co, La and Sc were 5.75, 36.3, 4.58, 15.67 and 4.00 mg/kg respectively. These results analysis had relative bias and u-test ranged from 0.4-11.3% and 0.15-2.25. The accuracy and precision evaluation based on International Atomic Energy Agency (IAEA criteria was also applied. The result showed that NAA technique is applicable for the environmental samples analysis, and it also showed that the NAA laboratory in BATAN Bandung has a good performance.   Keywords: NAA, inter-comparison, estuarine sediment, coal fly ash, environmental samples

  13. Delineating an alternate convergent synthesis of brexpiprazole: a ...

    Indian Academy of Sciences (India)

    A Sravanth Kumar

    2018-06-14

    Jun 14, 2018 ... that had reached the market with the approved indi- cation of schizophrenia ... nist induced adverse effects such as akathisia, insomnia,. *For correspondence .... Despite providing an alternate amination strategy,. Xiangrui's ...

  14. 76 FR 64325 - Advisory Committee on Earthquake Hazards Reduction Meeting

    Science.gov (United States)

    2011-10-18

    ... 2004 (Pub. L. 108-360). The Committee is composed of 12 members appointed by the Director of NIST, who...-U.S. citizens must also submit their country of citizenship, title, and employer/ sponsor. Mrs...

  15. Public Key Infrastructure Study

    National Research Council Canada - National Science Library

    Berkovits, Shimshon

    1994-01-01

    The National Institute of Standards and Technology (NIST) has tasked The MITRE Corporation to study the alternatives for automated management of public keys and of the associated public key certificates for the Federal Government...

  16. Evaluation for the habitability of the main control room and the performance of the smoke control system at NPP

    International Nuclear Information System (INIS)

    Ji, M. H.; Hong, S. R.; Sung, C. K.

    2002-01-01

    In addition to the indoor air conditioning, the habitability of the main control room for the operators at Nuclear Power Plants (NPP) has to be ensured with a strict design requirements to protect the workers from the radiation exposure, hazardous chemicals, and the smoke with toxic combustion products. With this context, the internal pressure of the control room envelope shall be sustained at slightly higher pressure than the atmospheric pressure. At this paper, the internal pressure of the control room envelope was analyzed by use of the evaluation program, CONTANW that was developed by the NIST. On the basis of design values, the performance status of the smoke control system was also checked by the program, CFAST that was released by the NIST to confirm the dynamic smoke behaviors

  17. Topography measurements for determining the decay factors in surface replication

    International Nuclear Information System (INIS)

    Song, J; Zheng, A; Vorburger, T V; Rubert, P

    2008-01-01

    The electro-forming technique is used at National Institute of Standards and Technology (NIST) for the production of standard reference material (SRM) 2461 standard casings to support nationwide ballistics measurement traceability and measurement quality control in the US. In order to ensure that the SRM casings are produced with virtually the same surface topography, it is necessary to test the decay factors of the replication process. Twenty-six replica casings are replicated from the same master casing for the decay factor tests. The NIST topography measurement system is used for measurements and correlations of surface topography. The topography decays are quantified by the cross-correlation function maximum CCF max . Based on the test, it is expected that 256 SRM casings can be replicated from the same master with CCF max values higher than 95%

  18. Calibration Of A 14 MeV Neutron Generator With Reference To NBS-1

    International Nuclear Information System (INIS)

    Heimbach, Craig R.

    2011-01-01

    NBS-1 is the US national neutron reference source. It has a neutron emission rate (June 1961) of 1.257x10 6 n/s 1,2,3 with an uncertainty of 0.85%(k = 1). Neutron emission-rate calibrations performed at the National Institute of Standards and Technology (NIST) are made in comparison to this source, either directly or indirectly. To calibrate a commercial 14 MeV neutron generator, NIST performed a set of comparison measurements to evaluate the neutron output relative to NBS-1. The neutron output of the generator was determined with an uncertainty of about 7%(k = 1). The 15-hour half-life of one of the reactions used also makes possible off-site measurements. Consideration is given to similar calibrations for a 2.5 MeV neutron generator.

  19. AmO2 Analysis for Analytical Method Testing and Assessment: Analysis Support for AmO2 Production

    Energy Technology Data Exchange (ETDEWEB)

    Kuhn, Kevin John [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Bland, Galey Jean [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Fulwyler, James Brent [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Garduno, Katherine [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Keller, Russell C. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Klundt, Dylan James [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Lujan, Elmer J. W [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Mark, Zoe Francoise Elise [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Mathew, Kattathu Joseph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Ortega, Laura Claire [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Ottenfeld, Chelsea Faith [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Porterfield, Donivan R. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Rearick, Michael Sean [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Rim, Jung Ho [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Schake, Ann Rene [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Schappert, Michael Francis [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Stanley, Floyd E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Thomas, Mariam R. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Wylie, Ernest Miller II [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Xu, Ning [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Tandon, Lav [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-09-08

    Americium oxide samples will be measured for various analytes to support AmO2 production. The key analytes that are currently requested by the Am production customer at LANL include total Am content, Am isotopics, Pu assay, Pu isotopics, and trace element content including 237Np content. Multiple analytical methods will be utilized depending on the sensitivity, accuracy and precision needs of the Am matrix. Traceability to the National Institute of Standards and Technology (NIST) will be achieved, where applicable, by running NIST traceable quality control materials. This given that there are no suitable AmO2 reference materials currently available for requested analytes. The primary objective is to demonstrate the suitability of actinide analytical chemistry methods to support AmO2 production operations.

  20. La légalisation de l’eugénisme en Espagne. Les théories de Jiménez de Asúa dans Libertad de amar y derecho a morir (1928

    Directory of Open Access Journals (Sweden)

    María Flores Rodríguez

    2013-03-01

    Full Text Available Cet article étudie les théories eugénistes du juriste et socialiste espagnol Luis Jiménez de Asúa, exposées dans son livre Libertad de amar y derecho a morir (1928, dont l’examen met en évidence l’importance des débats autour de la légalisation de l’eugénisme en Espagne. En démontrant sa viabilité juridique, fondée sur le respect du droit et des principes socialistes, Jiménez de Asúa ouvre de nouvelles perspectives au mouvement eugéniste espagnol, laissant entrevoir les contours d’un nouvel ordre, au détriment de la Dictature de Primo de Rivera, déjà sclérosée.

  1. Validation of method in instrumental NAA for food products sample

    International Nuclear Information System (INIS)

    Alfian; Siti Suprapti; Setyo Purwanto

    2010-01-01

    NAA is a method of testing that has not been standardized. To affirm and confirm that this method is valid. it must be done validation of the method with various sample standard reference materials. In this work. the validation is carried for food product samples using NIST SRM 1567a (wheat flour) and NIST SRM 1568a (rice flour). The results show that the validation method for testing nine elements (Al, K, Mg, Mn, Na, Ca, Fe, Se and Zn) in SRM 1567a and eight elements (Al, K, Mg, Mn, Na, Ca, Se and Zn ) in SRM 1568a pass the test of accuracy and precision. It can be conclude that this method has power to give valid result in determination element of the food products samples. (author)

  2. 40 CFR 1065.20 - Units of measure and overview of calculations.

    Science.gov (United States)

    2010-07-01

    ... document is available on the Internet at http://physics.nist.gov/Pubs/SP811/contents.html. Note the..., repeatability, linearity, or noise specification. See § 1065.1001 for the definition of tolerance. In this part...

  3. 75 FR 30779 - Notice of Jointly Owned Invention Available for Licensing

    Science.gov (United States)

    2010-06-02

    ... indicated below. The invention available for licensing is: [NIST DOCKET NUMBER: 10-004] Title: Gradient.... Gebbie, Director, Physics Laboratory. [FR Doc. 2010-13200 Filed 6-1-10; 8:45 am] BILLING CODE 3510-13-P ...

  4. Implementation of RSA 2048-bit and AES 256-bit with Digital Signature for Secure Electronic Health Record Application

    Directory of Open Access Journals (Sweden)

    Mohamad Ali Sadikin

    2016-10-01

    Full Text Available This research addresses the implementation of encryption and digital signature technique for electronic health record to prevent cybercrime such as robbery, modification and unauthorised access. In this research, RSA 2048-bit algorithm, AES 256-bit and SHA 256 will be implemented in Java programming language. Secure Electronic Health Record Information (SEHR application design is intended to combine given services, such as confidentiality, integrity, authentication, and nonrepudiation. Cryptography is used to ensure the file records and electronic documents for detailed information on the medical past, present and future forecasts that have been given only to the intended patients. The document will be encrypted using an encryption algorithm based on NIST Standard. In the application, there are two schemes, namely the protection and verification scheme. This research uses black-box testing and whitebox testing to test the software input, output, and code without testing the process and design that occurs in the system.We demonstrated the implementation of cryptography in SEHR. The implementation of encryption and digital signature in this research can prevent archive thievery.

  5. Electron Inelastic-Mean-Free-Path Database

    Science.gov (United States)

    SRD 71 NIST Electron Inelastic-Mean-Free-Path Database (PC database, no charge)   This database provides values of electron inelastic mean free paths (IMFPs) for use in quantitative surface analyses by AES and XPS.

  6. Application of instrumental neutron activation analysis for the examination of oil pigments

    International Nuclear Information System (INIS)

    Chung, Y.S.; Kim, S.H.; Sun, G.M.; Lim, J.M.; Moon, J.H.; Kim, Y.J.; Lim, S.J.; Song, Y.N.; Kim, K.

    2011-01-01

    This study is to investigate the applicability of instrumental neutron activation analysis (INAA) as a non-destructive examination tool for the quantitative chemical composition analysis associated with authentication, restoration and conservation of art objects in the field of cultural heritage. The quantitative analysis of major, minor and trace elements in Rembrandt's registered oil pigments recently collected at the Korean market as one of the art objects was carried out using INAA facilities of the HANARO research reactor at the Korea Atomic Energy Research Institute in collaboration with the National Museum of Contemporary Art in Korea. Analytical quality control was implemented using NIST SRM 2709, certified reference materials and metal standards. The analytical results for seventeen characteristic elements of thirty-one measured elements were statistically treated to identify the characteristic correlations and patterns between color and source of oil pigment and similarity degree of constituents using a cluster and discriminate analysis. (orig.)

  7. Development of a wireless monitoring system for fracture-critical bridges

    Science.gov (United States)

    Fasl, Jeremiah; Samaras, Vasilis; Reichenbach, Matthew; Helwig, Todd; Wood, Sharon L.; Potter, David; Lindenberg, Richard; Frank, Karl

    2011-04-01

    This paper provides a summary of ongoing research sponsored by the National Institute of Standards and Technology (NIST) that seeks to improve inspection practices for steel bridges by providing the technology and methodology for real-time monitoring. In order to reduce the time and cost of installing a monitoring system, the research team elected to use wireless communications within the sensor network. The investigation considered both IEEE 802.11 and IEEE 802.15.4 communications protocols and identified the latter as more practical for bridge monitoring applications. Studies were conducted to investigate possible improvements in the network performance using high-gain antennas. Results from experiments conducted outside and on bridges with different antennas are presented in this paper. Although some benefits were observed using high-gain antennas, the inconsistent performance and higher cost relative to the current stock, omni-directional antennas does not justify their use.

  8. Determination of essential and toxic elements in commercial baby foods by instrumental neutron activation analysis and atomic absorption spectrometry; Determinacao dos elementos essenciais e toxicos em alimentos comerciais infantis por analise por ativacao com neutrons e espectrometria de absorcao atomica

    Energy Technology Data Exchange (ETDEWEB)

    Vallinoto, Priscila

    2013-08-01

    The World Health Organization recommends that infants should be breast fed exclusively for at least six months after birth. After this period, it is recommended to start introducing complementary foods, in order to meet the child's nutritional, mineral and energy needs. Commercial food products for infants form an important part of the diet for many babies. Thus, it is very important that such food contains sufficient amounts of minerals. Inadequate complementary feeding is a major cause of high rates of infant malnutrition in developing countries. In this study, essential elements: Ca, Cl, Co, Cr, Fe, K, Mg, Mn, Na, Se and Zn and toxic elements: As, Cd, Hg levels were determined in twenty seven different commercial infant food product samples by Instrumental Neutron Activation Analysis (INAA) and Atomic Absorption Spectrometry (AAS). In order to validate both methodologies the reference material: INCT MPH-2 Mixed Polish Herbs and NIST - SRM 1577b Bovine Liver by INAA and NIST - SRM 1548th Typical Diet and NIST - SRM 1547 Peach Leaves by AAS were analyzed. The twenty seven baby food samples were acquired from Sao Paulo city supermarkets and stores. Essential and toxic elements were determined. Most of the essential element concentrations obtained were lower than the World Health Organization requirements, while concentrations of toxic elements were below the tolerable upper limit. These low essential element concentrations in these samples indicate that infants should not be fed only with commercial complementary foods. (author)

  9. Nondestructive assay of fluorine in geological and other materials by instrumental photon activation analysis with a microtron

    Energy Technology Data Exchange (ETDEWEB)

    Krausová, Ivana [Nuclear Physics Institute, Academy of Sciences of the Czech Republic, Řež 130, 25068 Řež (Czech Republic); Mizera, Jiří, E-mail: mizera@ujf.cas.cz [Nuclear Physics Institute, Academy of Sciences of the Czech Republic, Řež 130, 25068 Řež (Czech Republic); Institute of Rock Structure and Mechanics, Academy of Sciences of the Czech Republic, V Holešovičkách 41, 182 09 Praha 8 (Czech Republic); Řanda, Zdeněk; Chvátil, David; Krist, Pavel [Nuclear Physics Institute, Academy of Sciences of the Czech Republic, Řež 130, 25068 Řež (Czech Republic)

    2015-01-01

    Reliable determination of low concentrations of fluorine in geological and coal samples is difficult. It usually requires tedious decomposition and dissolution of the sample followed by chemical conversion of fluorine into its anionic form. The present paper examines possibilities of non-destructive determination of fluorine, mainly in minerals, rocks and coal, by instrumental photon activation analysis (IPAA) using the MT-25 microtron. The fluorine assay consists of counting the positron–electron annihilation line of {sup 18}F at 511 keV, which is a product of the photonuclear reaction {sup 19}F(γ, n){sup 18}F and a pure positron emitter. The assay is complicated by the simultaneous formation of other positron emitters. The main contributors to interference in geological samples are from {sup 45}Ti and {sup 34m}Cl, whereas those from {sup 44}Sc and {sup 89}Zr are minor. Optimizing beam energy and irradiation-decay-counting times, together with using interfering element calibration standards, allowed reliable IPAA determination of fluorine in selected USGS and CRPG geochemical reference materials, NIST coal reference materials, and NIST RM 8414 Bovine Muscle. In agreement with the published data obtained by PIGE, the results of the F assay by IPAA have revealed erroneous reference values provided for the NIST reference materials SRM 1632 Bituminous Coal and RM 8414 Bovine Muscle. The detection limits in rock and coal samples are in the range of 10–100 μg g{sup −1}.

  10. Meta-Cresol Purple Reference Material® (RM) for Seawater pH Measurements

    Science.gov (United States)

    Easley, R. A.; Waters, J. F.; Place, B. J.; Pratt, K. W.

    2016-02-01

    The pH of seawater is a fundamental quantity that governs the carbon dioxide - carbonate system in the world's oceans. High quality pH measurements for long-term monitoring, shipboard studies, and shorter-term biological studies (mesocosm and field experiments) can be ensured through a reference material (RM) that is compatible with existing procedures and which is traceable to primary pH measurement metrology. High-precision spectrophotometric measurements of seawater pH using an indicator dye such as meta-cresol purple (mCP) are well established. However, traceability of these measurements to the International System of Units (SI) additionally requires characterizing the spectrophotometric pH response of the dye in multiple artificial seawater buffers that themselves are benchmarked via primary pH (Harned cell) measurements at a range of pH, salinity, and temperature. NIST is currently developing such a mCP pH RM using this approach. This material will also incorporate new procedures developed at NIST for assessing the purity and homogeneity of the mCP reagent itself. The resulting mCP will provide long-term (years) stability and ease of shipment compared to artificial seawater pH buffers. These efforts will provide the oceanographic user community with a NIST issued mCP (RM), characterized as to its molar absorptivity values and acid dissociation constants (pKa), with uncertainties that comply with the Guide to the Expression of Uncertainty in Measurement (GUM).

  11. Determination of essential and toxic elements in commercial baby foods by instrumental neutron activation analysis and atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Vallinoto, Priscila

    2013-01-01

    The World Health Organization recommends that infants should be breast fed exclusively for at least six months after birth. After this period, it is recommended to start introducing complementary foods, in order to meet the child's nutritional, mineral and energy needs. Commercial food products for infants form an important part of the diet for many babies. Thus, it is very important that such food contains sufficient amounts of minerals. Inadequate complementary feeding is a major cause of high rates of infant malnutrition in developing countries. In this study, essential elements: Ca, Cl, Co, Cr, Fe, K, Mg, Mn, Na, Se and Zn and toxic elements: As, Cd, Hg levels were determined in twenty seven different commercial infant food product samples by Instrumental Neutron Activation Analysis (INAA) and Atomic Absorption Spectrometry (AAS). In order to validate both methodologies the reference material: INCT MPH-2 Mixed Polish Herbs and NIST - SRM 1577b Bovine Liver by INAA and NIST - SRM 1548th Typical Diet and NIST - SRM 1547 Peach Leaves by AAS were analyzed. The twenty seven baby food samples were acquired from Sao Paulo city supermarkets and stores. Essential and toxic elements were determined. Most of the essential element concentrations obtained were lower than the World Health Organization requirements, while concentrations of toxic elements were below the tolerable upper limit. These low essential element concentrations in these samples indicate that infants should not be fed only with commercial complementary foods. (author)

  12. 15 CFR 292.6 - Additional requirements.

    Science.gov (United States)

    2010-01-01

    ... OF STANDARDS AND TECHNOLOGY, DEPARTMENT OF COMMERCE NIST EXTRAMURAL PROGRAMS MANUFACTURING EXTENSION... procedures. Recipients and subrecipients are subject to all Federal laws and Federal and Department of Commerce policies, regulations, and procedures applicable to Federal financial assistance awards. ...

  13. Dignital Biological Converter

    Science.gov (United States)

    2014-01-03

    DARPA Contracting Officer: Michael Blackstone Submitted by: HEATHER GOUVIS Synthetic Genomics, Inc. 11149 NORTH TORREY PINES RD LA JOLLA, CA...Contracting Officer Representative (COR) Email: salit@nist.gov Michael Blackstone DARPA Contracting Officer Michael.Blackstone@darpa.mil DARPA

  14. From Research Assistant to Professional Research Assistance: Research Consulting as a Form of Research Practice

    Directory of Open Access Journals (Sweden)

    Dawn E. Pollon

    2013-01-01

    Full Text Available Research assistantships have long been viewed as an extension of the formal education process, a form of apprenticeship, and a pathway into the professional practice of research in institutional settings. However, there are other contexts in which researchers practice research. This self-study documents the formative role research assistantships played in the authors’ development as professional research consultants. Four professional research consultants who held research assistant positions during their master’s and doctoral studies describe the contributions of their research assistantship experiences to the advancement of their knowledge, skills, and passion for research and subsequently to their career decisions. Professional research consulting is identified as a natural extension of research assistant roles and a potential career path. The article enhances current understandings about the ways research assistantships contribute to the development of researchers, and specifically to the development of professional research consultants. The analysis will be of interest to students contemplating entering into research assistantships, current research assistants, current research assistant supervisors, academic staff looking to improve their research productivity, and department chairs.

  15. Evaluation of the capture cross section of natural Ti from 10-5eV to 20.106eV

    International Nuclear Information System (INIS)

    Simon, G.; Bersillon, O.; Mosinski, G.; Philis, C.; Trochon, J.; Verges, N.

    1977-01-01

    In the 10 -5 eV - 200 keV energy range a coherent resolved resonance parameter set has been determined for each titanium isotope. From these sets the titanium capture cross section has been calculated with the Reich-Moore formalism and corrected for the missing resonances. From 200 keV up to 20 MeV all the isotopic cross sections were calculated with the help of two statistical model codes NCNR and FISPRO. These calculations have been adjusted on available 50 Ti(n,γ) 51 Ti and Ti(n,γ) experimental results. The elemental titanium capture cross section has been obtained as the weighted sum of the isotopic cross sections. The present evaluation is descriptive of the experimental values. The comparison of the present evaluation with ENDF/BIV shows the ameliorations brought in this cross section: a better description of all the resonances known in the 1 keV - 200 keV energy range; above 200 keV the new data give a more realistic shape showing compound nucleus competition of prominent inelastic scattering channels. As titanium is used as structural material for fast reactors the capture cross section integrals for the two evaluations in different energy ranges are compared. These comparisons show considerable discrepancies in some areas. Thus the new evaluation may change the results of reactor calculations

  16. Evidence for Ventilation through Collective Respiratory Movements in Giant Honeybee (Apis dorsata) Nests.

    Science.gov (United States)

    Kastberger, Gerald; Waddoup, Dominique; Weihmann, Frank; Hoetzl, Thomas

    2016-01-01

    The Asian giant honeybees (Apis dorsata) build single-comb nests in the open, which makes this species particularly susceptible to environmental strains. Long-term infrared (IR) records documented cool nest regions (CNR) at the bee curtain (nCNR = 207, nnests > 20) distinguished by marked negative gradients (ΔTCNR/d 0) displaying the Venturi effect, which evidences funnel properties of CNRs. The air flows inwards through CNRs, which is verified by the negative spatial gradient ΔTCNR/d, by the positive grading of TCNR with Tamb and lastly by fanners which have directed their abdomens towards CNRs. Rare cases of RAT +0.4 cm2/s) displaying "inhalation" and "exhalation" cycling. "Inhalation" could be boosted by bees at the inner curtain layers, which stretch their extremities against the comb enlarging the inner nest lumen and thus causing a pressure fall which drives ambient air inwards through CNR funnels. The relaxing of the formerly "activated" bees could then trigger the "exhalation" process, which brings the bee curtain, passively by gravity, close to the comb again. That way, warm, CO2-enriched nest-borne air is pressed outwards through the leaking mesh of the bee curtain. This ventilation hypothesis is supported by IR imaging and laser vibrometry depicting CNRs in at least four aspects as low-resistance convection funnels for maintaining thermoregulation and restoring fresh air in the nest.

  17. Evidence for Ventilation through Collective Respiratory Movements in Giant Honeybee (Apis dorsata Nests.

    Directory of Open Access Journals (Sweden)

    Gerald Kastberger

    Full Text Available The Asian giant honeybees (Apis dorsata build single-comb nests in the open, which makes this species particularly susceptible to environmental strains. Long-term infrared (IR records documented cool nest regions (CNR at the bee curtain (nCNR = 207, nnests > 20 distinguished by marked negative gradients (ΔTCNR/d 0 displaying the Venturi effect, which evidences funnel properties of CNRs. The air flows inwards through CNRs, which is verified by the negative spatial gradient ΔTCNR/d, by the positive grading of TCNR with Tamb and lastly by fanners which have directed their abdomens towards CNRs. Rare cases of RAT +0.4 cm2/s displaying "inhalation" and "exhalation" cycling. "Inhalation" could be boosted by bees at the inner curtain layers, which stretch their extremities against the comb enlarging the inner nest lumen and thus causing a pressure fall which drives ambient air inwards through CNR funnels. The relaxing of the formerly "activated" bees could then trigger the "exhalation" process, which brings the bee curtain, passively by gravity, close to the comb again. That way, warm, CO2-enriched nest-borne air is pressed outwards through the leaking mesh of the bee curtain. This ventilation hypothesis is supported by IR imaging and laser vibrometry depicting CNRs in at least four aspects as low-resistance convection funnels for maintaining thermoregulation and restoring fresh air in the nest.

  18. Development of the NAA Laboratory for an Accreditation Obtains

    International Nuclear Information System (INIS)

    Sri Wardani; Rina M, Th.; Sunarko, M.; Ratnawati, E.

    2004-01-01

    The evaluation of capability of the neutron activation analysis comparative method and laboratory equipment at P2TRR have been performed by analyzed a reference standard materials prepared by NIST, namely: SRM 1646a and SRM 1648 by a both of comparative and ko- NAA methods. From the analysis results used a comparative method shown that the method and laboratory equipment used at P2TRR obtained in a good precision, accuracy and high sensitivity. In this experiments a few elements could analyzed, namely: V, Ti, Mn, Cl, As, Sm, La, Na, Sc, Cr, Fe, Co, Se, Br, In, Sb, Ba, Cs, Ce, W, U, and Zn. The deviation values results compared with certificate values (NIST) obtained in a range 2 - 12.5% with confidence levels in range 68 - 98%. While, a reference standard material of SRM 1648 analyzed by k 0 -NAA method shown that the method need more research and study continued. From the qualitatively analysis results for short-lived nuclides category analysis by k 0 -NAA could identified a few elements, namely: V, Cu, Na, As and U with standard deviation values in range 1- 11% and limit detection values are 1.6 (U), 6.4 (Cu), 11.2 (V), 73.3 (As) and 199.9 (Na) μg/g for a SRM 1648. For analysis of CRM 8 the results obtained on standard deviation values in range 1 - 13 % and limit detection of 0.71 (Cu), 1.2 (As), 2.4 (V) and 375.9 (Na) μg/g. (author)

  19. CODATA recommended values of the fundamental constants

    International Nuclear Information System (INIS)

    Mohr, Peter J.; Taylor, Barry N.

    2000-01-01

    A review is given of the latest Committee on Data for Science and Technology (CODATA) adjustment of the values of the fundamental constants. The new set of constants, referred to as the 1998 values, replaces the values recommended for international use by CODATA in 1986. The values of the constants, and particularly the Rydberg constant, are of relevance to the calculation of precise atomic spectra. The standard uncertainty (estimated standard deviation) of the new recommended value of the Rydberg constant, which is based on precision frequency metrology and a detailed analysis of the theory, is approximately 1/160 times the uncertainty of the 1986 value. The new set of recommended values as well as a searchable bibliographic database that gives citations to the relevant literature is available on the World Wide Web at physics.nist.gov/constants and physics.nist.gov/constantsbib, respectively

  20. Researching collaboratively: implications for qualitative research and researchers.

    Science.gov (United States)

    Cheek, Julianne

    2008-11-01

    Often discussions about collaborative research, and collaboration generally, begin at the point of how to collaborate, who to collaborate with, and what to collaborate about. Rarely do they include equally important questions of why we are having discussions about collaboration, where such an impetus and emphasis is coming from, and how it connects to the contemporary political research context. In a recent editorial in Qualitative Health Research, Janice Morse highlighted the need for reflection about collaboration. This article responds to that call, providing reflections on collaboration, the imperative to collaborate, and what this all might mean for both qualitative research and qualitative researchers. I hope to stimulate new points of departure for thinking and action shaping collaborative research endeavors without-and just as crucially, within-qualitative research.

  1. CHAOS-BASED ADVANCED ENCRYPTION STANDARD

    KAUST Repository

    Abdulwahed, Naif B.

    2013-01-01

    This thesis introduces a new chaos-based Advanced Encryption Standard (AES). The AES is a well-known encryption algorithm that was standardized by U.S National Institute of Standard and Technology (NIST) in 2001. The thesis investigates and explores

  2. The South African guidelines on Enuresis—2017 | Adam | African ...

    African Journals Online (AJOL)

    ... Mirabegron (3-adrenoreceptor ago-nists), and Tricyclic Antidepressants (TCA)], alternative treatments, complementary therapies, urotherapy,alarm therapy, psychological therapy and biofeedback. The role of the Bladder Diary, additional investiga-tions and Mobile Phone Applications (Apps) in enuresis is also explored.

  3. 76 FR 66684 - Submission for OMB Review; Comment Request

    Science.gov (United States)

    2011-10-27

    ... revised to reflect NIST's ``Next Generation Strategy.'' This new strategy focuses on growth and innovation for manufacturers. The information will inform management and stakeholders of the strategy's effectiveness. Affected Public: Business or other for-profit organizations. Frequency: Annually. Respondent's...

  4. Progress, Performance, and Prospects of Ultra-High Resolution Microcalorimeter Spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    Hoover, Andrew Scott [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Bennett, D. A. [National Inst. of Standards and Technology (NIST), Boulder, CO (United States); Croce, Mark Philip [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Rabin, Michael W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Ullom, J. N. [National Inst. of Standards and Technology (NIST), Boulder, CO (United States); Univ. of Colorado, Boulder, CO (United States)

    2017-01-23

    In 2005 the LANL/NIST team used a single high-resolution microcalorimeter detector to measure the gamma-ray spectrum of a plutonium sample. After more than a decade of research and development on this topic, both the technology and our general understanding of its capabilities have advanced greatly, such that a progress review is now timely. We examine the scenario of a large-scale reprocessing plant and conclude that current non-destructive analysis (NDA) methods are inadequate to safeguard such a facility to the desired levels, leading to undesirable dependence on massspectrometry (MS) destructive analysis (DA). The development of microcalorimeter detectors is intended to close the performance gap between NDA and DA methods to address the needs of nuclear facilities.

  5. NVLAP calibration laboratory program

    Energy Technology Data Exchange (ETDEWEB)

    Cigler, J.L.

    1993-12-31

    This paper presents an overview of the progress up to April 1993 in the development of the Calibration Laboratories Accreditation Program within the framework of the National Voluntary Laboratory Accreditation Program (NVLAP) at the National Institute of Standards and Technology (NIST).

  6. Dgroup: DG00452 [KEGG MEDICUS

    Lifescience Database Archive (English)

    Full Text Available nist ... DG01468 ... Dopamine D2-receptor agonist ... DG01964 ... Ergot alkaloid ... DG01967 ... Antiparkinson agent Cyp subs...trate ... DG01633 ... CYP3A substrate ATC code: G02CB01 N04BC01 Antiparkinsonian, Dopam

  7. 77 FR 64314 - National Cybersecurity Center of Excellence (NCCoE)

    Science.gov (United States)

    2012-10-19

    ...-01] National Cybersecurity Center of Excellence (NCCoE) AGENCY: National Institute of Standards and... of interest in collaborating with NIST/ITL on an ongoing basis in the National Cybersecurity Center of Excellence (NCCoE) through partnerships called ``National Cybersecurity Excellence Partnerships...

  8. 78 FR 64478 - Request for Comments on the Preliminary Cybersecurity Framework

    Science.gov (United States)

    2013-10-29

    ...-01] Request for Comments on the Preliminary Cybersecurity Framework AGENCY: National Institute of... Cybersecurity Framework (``preliminary Framework''). The preliminary Framework was developed by NIST using... Cybersecurity'' (``Executive Order''). Under the Executive Order, the Secretary of Commerce is tasked to direct...

  9. 76 FR 17287 - Protocol Gas Verification Program and Minimum Competency Requirements for Air Emission Testing

    Science.gov (United States)

    2011-03-28

    ... definitions, revising certain compliance dates, and clarifying the language and applicability of certain..., adding two new definitions, updating recordkeeping/reporting formats, and clarifying the language and... uncertainty'' and ``coverage factor'' (see http://physics.nist.gov/cuu/Uncertainty/coverage.html ). 10...

  10. 15 CFR 290.2 - Definitions.

    Science.gov (United States)

    2010-01-01

    ... operational, management and financial sensse to improve the levels of technology they employ. ... STANDARDS AND TECHNOLOGY, DEPARTMENT OF COMMERCE NIST EXTRAMURAL PROGRAMS REGIONAL CENTERS FOR THE TRANSFER OF MANUFACTURING TECHNOLOGY § 290.2 Definitions. (a) The phrase advanced manufacturing technology...

  11. 15 CFR 10.0 - General.

    Science.gov (United States)

    2010-01-01

    ...) Lack of government sponsorship would result in significant public disadvantage for legal reasons or... current with respect to advancing technology and marketing practices. (e) Role of the National Institute of Standards & Technology. The National Institute of Standards & Technology (NIST) administers these...

  12. 77 FR 21538 - Announcing DRAFT Revisions to Federal Information Processing Standard (FIPS) 186-3, Digital...

    Science.gov (United States)

    2012-04-10

    ...-01] Announcing DRAFT Revisions to Federal Information Processing Standard (FIPS) 186-3, Digital... Technology (NIST) requests comments on revisions to Federal Information Processing Standard (FIPS) 186-3... 25, 2012. ADDRESSES: Written comments may be sent to: Chief, Computer Security Division, Information...

  13. 15 CFR 291.6 - Additional requirements; Federal policies and procedures.

    Science.gov (United States)

    2010-01-01

    ... and Foreign Trade NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, DEPARTMENT OF COMMERCE NIST... requirements; Federal policies and procedures. Recipients and subrecipients are subject to all Federal laws and Federal and Department of Commerce policies, regulations, and procedures applicable to Federal financial...

  14. 78 FR 34347 - Proposed Information Collection; Comment Request; the Building Construction Technology Extension...

    Science.gov (United States)

    2013-06-07

    ... DEPARTMENT OF COMMERCE National Institute of Standards and Technology Proposed Information..., DC 20230 (or via the Internet at [email protected] ). FOR FURTHER INFORMATION CONTACT: Requests for... information collection. Sponsored by the National Institute of Standards and Technology (NIST), the...

  15. 77 FR 47817 - Proposed Information Collection; Comment Request; Usage of Elevators for Occupant Evacuation...

    Science.gov (United States)

    2012-08-10

    ... DEPARTMENT OF COMMERCE National Institute of Standards and Technology Proposed Information... Institute of Standards and Technology (NIST), Commerce. ACTION: Notice. SUMMARY: The Department of Commerce... by occupants of existing multi- story buildings in the United States during fire emergencies. This...

  16. 78 FR 72063 - Open Meeting of the Information Security and Privacy Advisory Board

    Science.gov (United States)

    2013-12-02

    ... NIST on information security and privacy issues pertaining to federal computer systems. Details... Information Security and Privacy Advisory Board AGENCY: National Institute of Standards and Technology, Commerce. ACTION: Notice. SUMMARY: The Information Security and Privacy Advisory Board (ISPAB) will meet...

  17. NVLAP calibration laboratory program

    International Nuclear Information System (INIS)

    Cigler, J.L.

    1993-01-01

    This paper presents an overview of the progress up to April 1993 in the development of the Calibration Laboratories Accreditation Program within the framework of the National Voluntary Laboratory Accreditation Program (NVLAP) at the National Institute of Standards and Technology (NIST)

  18. Security Certification Challenges in a Cloud Computing Delivery Model

    Science.gov (United States)

    2010-04-27

    Relevant Security Standards, Certifications, and Guidance  NIST SP 800 series  ISO /IEC 27001 framework  Cloud Security Alliance  Statement of...CSA Domains / Cloud Features ISO 27001 Cloud Service Provider Responsibility Government Agency Responsibility Analyze Security gaps Compensating

  19. Mejora de la calidad de las medidas de ozono mediante un fotómetro UV de referencia Improvement of the quality of the ozone measurements by means of a standard reference photometer

    Directory of Open Access Journals (Sweden)

    R. Fernández Patier

    2001-11-01

    Full Text Available La Directiva 92/72/CE hace referencia al método de análisis descrito en la UNE 77-221:2000 y a que los analizadores de ozono se deben calibrar con un fotómetro UV de referencia o con un patrón transferido.De la necesidad de desarrollar un procedimiento que asegure la calidad y la trazabilidad de las mediciones en España, el Área de Contaminación Atmosférica ha decidido implantar un fotómetro UV de referencia NIST como patrón de ozono.Teniendo en cuenta los procedimientos empleados por EPA y NIST, se ha desarrollado un procedimiento de verificación consistente en la realización de 6 comparaciones del Patrón Transferido frente al Fotómetro UV de Referencia NIST, en días diferentes, analizándose, como mínimo, 5 concentraciones de ozono diferentes. Cada comparación se inicia y se finaliza siempre con una concentración de 0 ppb de O3. De cada comparación se obtiene una regresión lineal.Una vez realizadas las 6 comparaciones se obtiene la Recta de calibración y se calcula la incertidumbre asociada al patrón transferido.Se ha realizado la verificación de 17 patrones transferidos de los que 11 son fotómetros UV, 2 son generadores de ozono y 4 son generadores de ozono de bancos de dilución.De los resultados se concluye que las incertidumbres de los generadores de ozono, en general, son mayores que las de los fotómetros UV, recomendándose estos últimos como patrones transferidos.Destacar que mediante la utilización de los patrones transferidos para la calibración de analizadores de ozono se garantiza tanto la calidad como la trazabilidad de los datos generados.The Directive 92/72/CE makes reference to the analysis method described in the UNE 77-221:2000 and to the fact that the ozone analyzers shall be calibrated with a UV reference photometer or with a transfer standard.From the need of developing a procedure that assure the quality and the trazability of the measurements in Spain, the Atmospheric Pollution Area has decided

  20. {sup 6}LiF:ZnS(Ag) Neutrons Scintillator Detector Configuration for Optimal Readout

    Energy Technology Data Exchange (ETDEWEB)

    Osovizky, A. [NIST Center for Neutron Research, Gaithersburg, Maryland (United States); Rotem Industries Ltd, Rotem Industrial Park (Israel); University of Maryland, College park, Maryland (United States); Yehuda-Zada, Y.; Ghelman, M.; Tsai, P.; Thompson, A.K. [Nuclear Research Center Negev, Beer-Sheva (Israel); Pritchard, K.; Ziegler, J.B.; Ibberson, R.M.; Majkrzak, C.F.; Maliszewskyj, N.C. [NIST Center for Neutron Research, Gaithersburg, Maryland (United States)

    2015-07-01

    A Chromatic Analysis Neutron Diffractometer Or Reflectometer (CANDOR) is under development at the NIST Center for Neutron Research (NCNR). The CANDOR neutron sensor will rely on scintillator material for detecting the neutrons scattered by the sample under test. It consists of {sup 6}LiF:ZnS(Ag) scintillator material into which wavelength shifting (WLS) fibers have been embedded. Solid state photo-sensors (silicon photomultipliers) coupled to the WLS fibers are used to detect the light produced by the neutron capture event ({sup 6}Li (n,α) {sup 3}H reaction) and ionization of the ZnS(Ag). This detector configuration has the potential to accomplish the CANDOR performance requirements for efficiency of 90% for 5 A (3.35 meV) neutrons with high gamma rejection (10{sup 7}) along with compact design, affordable cost and materials availability. However this novel design includes challenges for precise neutron detection. The recognizing of the neutron signature versus the noise event produce by gamma event cannot be easy overcome by pulse height discrimination obstacle as can be achieved with {sup 3}He gas tube. Furthermore the selection of silicon photomultipliers (SiPM) as the light sensor maintains the obstacle of dark noise that does not exist when a photomultiplier tube is coupled to the scintillator. A proper selection of SiPM should focus on increasing the output signal and reducing the dark noise in order to optimize the detection sensitivity and to provide a clean signal pulse shape discrimination. The main parameters for evaluation are: - Quantum Efficiency (QE) - matching the SiPM peak QE with the peak transmission wavelength emission of the WLS. - Recovery time - a short recovery time is preferred to minimize the pulse width beyond the intrinsic decay time of the scintillator crystal (improves the gamma rejection based output pulse shape (time)). - Diode dimensions -The dark noise is proportional to the diode active area while the signal is provided by the

  1. Multivariate optimization of an analytical method for the analysis of dog and cat foods by ICP OES.

    Science.gov (United States)

    da Costa, Silvânio Silvério Lopes; Pereira, Ana Cristina Lima; Passos, Elisangela Andrade; Alves, José do Patrocínio Hora; Garcia, Carlos Alexandre Borges; Araujo, Rennan Geovanny Oliveira

    2013-04-15

    Experimental design methodology was used to optimize an analytical method for determination of the mineral element composition (Al, Ca, Cd, Cr, Cu, Ba, Fe, K, Mg, Mn, P, S, Sr and Zn) of dog and cat foods. Two-level full factorial design was applied to define the optimal proportions of the reagents used for microwave-assisted sample digestion (2.0 mol L(-1) HNO3 and 6% m/v H2O2). A three-level factorial design for two variables was used to optimize the operational conditions of the inductively coupled plasma optical emission spectrometer, employed for analysis of the extracts. A radiofrequency power of 1.2 kW and a nebulizer argon flow of 1.0 L min(-1) were selected. The limits of quantification (LOQ) were between 0.03 μg g(-1) (Cr, 267.716 nm) and 87 μg g(-1) (Ca, 373.690 nm). The trueness of the optimized method was evaluated by analysis of five certified reference materials (CRMs): wheat flour (NIST 1567a), bovine liver (NIST 1577), peach leaves (NIST 1547), oyster tissue (NIST 1566b), and fish protein (DORM-3). The recovery values obtained for the CRMs were between 80 ± 4% (Cr) and 117 ± 5% (Cd), with relative standard deviations (RSDs) better than 5%, demonstrating that the proposed method offered good trueness and precision. Ten samples of pet food (five each of cat and dog food) were acquired at supermarkets in Aracaju city (Sergipe State, Brazil). Concentrations in the dog food ranged between 7.1 mg kg(-1) (Ba) and 2.7 g kg(-1) (Ca), while for cat food the values were between 3.7 mg kg(-1) (Ba) and 3.0 g kg(-1) (Ca). The concentrations of Ca, K, Mg, P, Cu, Fe, Mn, and Zn in the food were compared with the guidelines of the United States' Association of American Feed Control Officials (AAFCO) and the Brazilian Ministry of Agriculture, Livestock, and Food Supply (Ministério da Agricultura, Pecuária e Abastecimento-MAPA). Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Elemental fractionation in 785 nm picosecond and femtosecond laser ablation inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Shaheen, M.E.; Gagnon, J.E.; Fryer, B.J.

    2015-01-01

    Elemental fractionation and ICP-MS signal response were investigated for two different pulse width laser beams originating from the same laser system. Femtosecond and picosecond laser beams at pulse widths of 130 fs and 110 ps, respectively, and wavelength of 785 nm were used to ablate NIST 610 synthetic glass and SRM 1107 Naval Brass B at the same spot for 800 to 1000 laser pulses at different repetition rates (5 to 50 Hz). Elemental fractionation was found to depend on repetition rate and showed a trend with femtosecond laser ablation that is opposite to that observed in picosecond laser ablation for most measured isotopes. ICP-MS signal intensity was higher in femtosecond than picosecond LA-ICP-MS in both NIST 610 and naval brass when ablation was conducted under the same fluence and repetition rate. The differences in signal intensity were partly related to differences in particle size distribution between particles generated by femtosecond and picosecond laser pulses and the consequent differences in transport and ionization efficiencies. The main reason for the higher signal intensity resulting from femtosecond laser pulses was related to the larger crater sizes compared to those created during picosecond laser ablation. Elemental ratios measured using 66 Zn/ 63 Cu, 208 Pb/ 238 U, 232 Th/ 238 U, 66 Zn/ 232 Th and 66 Zn/ 208 Pb were found to change with the number of laser pulses with data points being more scattered in picosecond than femtosecond laser pulses. Reproducibility of replicate measurements of signal intensities, fractionation and elemental ratios was better for fs-LA-ICP-MS (RSD ~ 3 to 6%) than ps-LA-ICP-MS (RSD ~ 7 to 11%). - Highlights: • Fractionation and ICP-MS signal response were investigated for two different pulse widths using NIST 610 and Naval Brass. • Dependence of fractionation indices on repetition rate and pulse width. • Higher ablation rate was observed in picosecond compared to femtosecond laser ablation of NIST 610 and Brass

  3. MO-D-BRD-01: Clinical Implementation of An Electronic Brachytherapy Program for the Skin

    International Nuclear Information System (INIS)

    Ouhib, Z.

    2015-01-01

    brachytherapy and the various applications for which it is being used. To understand the physics of the calibration and commissioning for electronic brachytherapy sources To understand the unique radiobiology and clinical implementation of electronic brachytherapy systems for skin and IORT techniques Xoft, Inc. contributed funding toward development of the NIST electronic brachytherapy facility (Michael Mitch).The University of Wisconsin (Wesley Culberson) has received research support funding from Xoft, Inc. Zoubir Ouhib has received partial funding from Elekta Esteya

  4. MO-D-BRD-03: Radiobiology and Commissioning of Electronic Brachytherapy for IORT

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, J. [Oregon Health & Science Univ (United States)

    2015-06-15

    brachytherapy and the various applications for which it is being used. To understand the physics of the calibration and commissioning for electronic brachytherapy sources To understand the unique radiobiology and clinical implementation of electronic brachytherapy systems for skin and IORT techniques Xoft, Inc. contributed funding toward development of the NIST electronic brachytherapy facility (Michael Mitch).The University of Wisconsin (Wesley Culberson) has received research support funding from Xoft, Inc. Zoubir Ouhib has received partial funding from Elekta Esteya.

  5. Quantitative 3D elemental analysis inside plant roots by means of synchrotron confocal micro X-ray fluorescence

    Science.gov (United States)

    Terzano, R.; Vekemans, B.; Tomasi, N.; Spagnuolo, M.; Schoonjans, T.; Vincze, L.; Pinton, R.; Cesco, S.; Ruggiero, P.

    2009-04-01

    The knowledge of the distribution and concentration of elements within plants is a fundamental step to better understand how these plants uptake specific elements from the medium of growth and how they manage acquisition and compartmentalisation of nutrients as well as toxic metals. For some elements, either nutrients or toxicants, it can be of relevance to know their concentration level within microscopic volumes in plant organs, where they are stored or accumulated. Usually, this type of microscopic analysis requires complex cutting procedures and extensive sample manipulations. In this research, the technique of synchrotron micro X-ray fluorescence in the confocal mode was applied to image the distribution of elements in selected key-planes of tomato roots without the need of any sample preparation, except washing and freeze-drying. Using this method, a first polycapillary lens focussed the X-ray beam with an energy of 12.4 keV down to a 20 µm beam that is penetrating the sample, and a second polycapillary half-lens, that was positioned at the detection side at 90 degrees to the first polycapillary, could then restrict further the view on this irradiated volume to a defined microscopic volume (typically 20x20x20 µm3) from which the induced fluorescent radiation is finally collected by the energy dispersive detector. In this way, it was possible to investigate the concentration levels of some elements such as K, Ca, Mn, Fe, Cu and Zn within the roots of tomato plants. The quantification was performed by means of a dedicated XRF Fundamental Parameter (FP) method in order to calculate the concentrations of trace elements within the analysed plants. Utilizing fundamental atomic parameters, the applied FP method is taking into account the influence of sample self-absorption and especially the specific detection processes by the polycapillary lens. Quantification was assessed and validated by using different standards: NIST SRM 1573a (trace elements in tomato leaves

  6. 75 FR 38595 - Guidance to States Regarding Driver History Record Information Security, Continuity of Operation...

    Science.gov (United States)

    2010-07-02

    ... licensing agencies, NIST Interagency Report (IR) 7621, Small Business Information Security: The Fundamentals... emergency. These plans should include a business impact analysis (BIA) to determine: the interdependence of... associated with restoring critical functions (including a line of succession in cases of staff unavailability...

  7. 78 FR 54453 - Notice of Public Meeting-Intersection of Cloud Computing and Mobility Forum and Workshop

    Science.gov (United States)

    2013-09-04

    ...--Intersection of Cloud Computing and Mobility Forum and Workshop AGENCY: National Institute of Standards and.../intersection-of-cloud-and-mobility.cfm . SUPPLEMENTARY INFORMATION: NIST hosted six prior Cloud Computing Forum... interoperability, portability, and security, discuss the Federal Government's experience with cloud computing...

  8. 78 FR 5186 - Clinical Flow Cytometry in Hematologic Malignancies; Public Workshop; Request for Comments

    Science.gov (United States)

    2013-01-24

    ... need for such products to assist clinical laboratories in performing this testing. FDA has been working... this workshop include: (1) Overview of Quality control and standardization issues associated with Clinical Flow Cytometry (FCM), including discussion of a NIST traceable standard; (2) Biological controls...

  9. Bayeuxtapetens marginaler - ett utrymme för kommunikation om kvinnligt och manligt? = Medieval margins - a site of communicatin about male and female? / Agneta Ney

    Index Scriptorium Estoniae

    Ney, Agneta

    2006-01-01

    Bayeux' gobeläänist, mis kujutab Inglismaa vallutamist 11. sajandil normannide poolt - uurimus on vastukajaks kunstiteadlase Michael Camille'i arvamusele, et vaibaäärtel on kujutatud misogüüne. Naiste kujutamisest vaibal, oletatavatest põhjustest ja tähendustest

  10. Channel-dependent GMM and multi-class logistic: Regression models for language recognition

    NARCIS (Netherlands)

    Leeuwen, D.A. van; Brümmer, Niko

    2006-01-01

    This paper describes two new approaches to spoken language recognition. These were both successfully applied in the NIST 2005 Language Recognition Evaluation. The first approach extends the Gaussian Mixture Model technique with channel dependency, which results in actual detection costs (CDET) of

  11. 76 FR 17838 - Proposed Information Collection; Comment Request; Usage of Elevators for Occupant Evacuation...

    Science.gov (United States)

    2011-03-31

    ... DEPARTMENT OF COMMERCE National Institute of Standards and Technology Proposed Information... Institute of Standards and Technology (NIST), Commerce. ACTION: Notice. SUMMARY: The Department of Commerce... is to gain an understanding of how elevators are currently used by occupants of existing multi- story...

  12. 75 FR 78225 - Proposed Information Collection; Comment Request; Building for Environmental and Economic...

    Science.gov (United States)

    2010-12-15

    ... flows from raw material extraction through product disposal) to decision-enabling results and delivers... stages in the life of a product are analyzed: Raw material acquisition, manufacture, transportation... investment, replacement, operation, maintenance and repair, and disposal. NIST will publish in BEES Online...

  13. 75 FR 33766 - Manufacturing Extension Partnership (MEP) Availability of Funds for Projects To Develop Client...

    Science.gov (United States)

    2010-06-15

    ... Strategic Growth Areas are: supply chain, sustainability, technology acceleration, workforce and continuous... strengthen the global competitiveness of small- and medium-sized U.S. based manufacturing firms. NIST MEP... Agreements Management Division; National Institute of Standards and Technology; 100 Bureau Drive, Stop 1650...

  14. 76 FR 34650 - Announcing a Meeting of the Information Security and Privacy Advisory Board

    Science.gov (United States)

    2011-06-14

    ... Commerce and the Director of NIST on security and privacy issues pertaining to federal computer systems... Information Security and Privacy Advisory Board AGENCY: National Institute of Standards and Technology, Department of Commerce. ACTION: Notice. SUMMARY: The Information Security and Privacy Advisory Board (ISPAB...

  15. Action Research and Interactive Research

    DEFF Research Database (Denmark)

    Svensson, lennart; Nielsen, Kurt Aagaard

    2006-01-01

    The authors present trends in Nordic action research. They ask critical questions in the development towards mode 2 and points out alternative roads for a scientific consolidation of action research and interactive research.......The authors present trends in Nordic action research. They ask critical questions in the development towards mode 2 and points out alternative roads for a scientific consolidation of action research and interactive research....

  16. INAA at the top of the world: Elemental characterization and analysis of airborne particulate matter collected in the Himalayas at 5,100 m high

    International Nuclear Information System (INIS)

    Giaveri, G.; Bergamaschi, L.; Rizzio, E.; Brandone, A.; Profumo, A.; Gallorini, M.; Zambelli, G.; Baudo, R.; Tartari, G.

    2005-01-01

    In 1990, following an agreement with the Royal Nepal Academy of Science, the Italian National Research Council (CNR) installed a scientific laboratory (Pyramid) at 5,050 m (s.l.) in the Himalayan region. Among the environmental related researches, the task project RATEAP (Remote Areas Trace Elements Atmospheric Pollution), started in 2001, aims at obtaining information about the chemical composition of the high altitude airborne particulate matter. During the period of March-April 2002 series of samplings have been carried out by pump aspiration. Samples of total suspended particles (TSP) as well as of the particles size fraction PM10 and PM 2.5 have been collected and submitted to INAA for the determination of more than 30 elements present, at nanogram levels, in few micrograms of air dust. Data quality assurance has been performed by the analysis of different NIST SRMs and, in particular, the SRM 2783 Air particulate on Filter Media. (author)

  17. Application of instrumental neutron activation analysis for the examination of oil pigments

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Y.S.; Kim, S.H.; Sun, G.M.; Lim, J.M.; Moon, J.H.; Kim, Y.J. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Lim, S.J.; Song, Y.N.; Kim, K. [National Museum of Contemporary Art, Gwacheon, Gyeonggi-do (Korea, Republic of)

    2011-07-01

    This study is to investigate the applicability of instrumental neutron activation analysis (INAA) as a non-destructive examination tool for the quantitative chemical composition analysis associated with authentication, restoration and conservation of art objects in the field of cultural heritage. The quantitative analysis of major, minor and trace elements in Rembrandt's {sup registered} oil pigments recently collected at the Korean market as one of the art objects was carried out using INAA facilities of the HANARO research reactor at the Korea Atomic Energy Research Institute in collaboration with the National Museum of Contemporary Art in Korea. Analytical quality control was implemented using NIST SRM 2709, certified reference materials and metal standards. The analytical results for seventeen characteristic elements of thirty-one measured elements were statistically treated to identify the characteristic correlations and patterns between color and source of oil pigment and similarity degree of constituents using a cluster and discriminate analysis. (orig.)

  18. Determination of polychlorinated dibenzo-p-dioxin and dibenzofuran congeners in air particulate and marine sediment standard reference materials (SRMs).

    Science.gov (United States)

    Chiu, C H; Turle, R; Poole, G; Thibert, B; Brubaker, W W; Schantz, M M; Wise, S A

    2001-02-01

    Due to the limited number of environmental matrix certified reference materials (CRMs) with assigned values for natural levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), an interlaboratory study was undertaken by the National Institute of Standards and Technology (NIST) and Environment Canada to establish reference concentration values for selected PCDD/Fs in two well-characterized NIST Standard Reference Materials (SRMs): SRM 1649a (Urban Dust) and SRM 1944 (New York/New Jersey Waterway Sediment). Results from 14 laboratories were used to provide reference values for the seventeen 2, 3, 7, 8-substituted PCDD/F congeners, the totals for individual tetra- through hepta-substituted PCDD/F homologues, and the total amount of tetra- through hepta-substituted PCDD/Fs. The mass fractions for the individual 2, 3, 7, 8-substituted congeners range from approximately 0.01 microg/kg to 7 microg/kg dry mass.

  19. A blind test on the pulse tube refrigerator model (PTRM)

    International Nuclear Information System (INIS)

    Yuan, S.W.K.; Radebaugh, R.

    1996-01-01

    The Stirling Refrigerator Performance Model (SRPM) has been validated extensively against the Lockheed built Stirling Coolers and various units in the literature. This model has been modified to predict the performance of the Pulse Tube Coolers (PTCs). It was successfully validated against a Lockheed in-house-built PTC. The results are to be published elsewhere. In this paper, the validation of PTRM against a NIST (National Institute of Standards and Technology) orifice pulse tube cooler is reported. Dimensions and operating condition of the PTC were obtained from NIST without prior knowledge of the performance. In other words, this is a open-quote blind test close-quote on the PTRM with the help of the National Institute of Standards and Technology. Good correlation was found between the test data and the prediction. PTRM is a generic model that gives accurate performance prediction of the pulse tube coolers

  20. Scanning vs. single spot laser ablation (λ=213 nm) inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Gonzalez, Jhanis J.; Fernandez, Alberto; Mao Xianglei; Russo, Richard E.

    2004-01-01

    Sampling strategy is defined in this work as the interaction of a repetitively pulsed laser beam with a fixed position on a sample (single spot) or with a moving sample (scan). Analytical performance of these sampling strategies was compared by using 213 nm laser ablation ICP-MS. A geological rock (Tuff) was quantitatively analyzed based on NIST series 610-616 glass standard reference materials. Laser ablation data were compared to ICP-MS analysis of the dissolved samples. The scan strategy (50 μm/s) produced a flat, steady temporal ICP-MS response whereas the single spot strategy produced a signal that decayed with time (after 60 s). Single-spot sampling provided better accuracy and precision than the scan strategy when the first 15 s of the sampling time was eliminated from the data analysis. In addition, the single spot strategy showed less matrix dependence among the four NIST glasses

  1. Instrumental neutron activation analysis of rib bone samples and of bone reference materials

    International Nuclear Information System (INIS)

    Saiki, M.; Takata, M.K.; Kramarski, S.; Borelli, A.

    2000-01-01

    The instrumental neutron activation analysis method was used for the determination of trace elements in rib bone samples taken from autopsies of accident victims. The elements Br, Ca, Cl, Cr, Fe, Mg, Mn, Na, P, Sr, Rb and Zn were determined in cortical tissues by using short and long irradiations with thermal neutron flux of the IEA-R1m nuclear reactor. The reference materials NIST SRM 1400 Bone Ash and NIST SRM 1486 Bone Meal were also analyzed in order to evaluate the precision and the accuracy of the results. It was verified that lyophilization is the most convenient process for drying bone samples since it does not cause any element losses. Comparisons were made between the results obtained for rib samples and the literature values as well as between the results obtained for different ribs from a single individual and for bones from different individuals. (author)

  2. Side channel analysis of some hash based MACs:A response to SHA-3 requirements

    DEFF Research Database (Denmark)

    The forthcoming NIST's Advanced Hash Standard (AHS) competition to select SHA-3 hash function requires that each candidate hash function submission must have at least one construction to support FIPS 198 HMAC application. As part of its evaluation, NIST is aiming to select either a candidate hash...... function which is more resistant to known side channel attacks (SCA) when plugged into HMAC, or that has an alternative MAC mode which is more resistant to known SCA than the other submitted alternatives. In response to this, we perform differential power analysis (DPA) on the possible smart card...... implementations of some of the recently proposed MAC alternatives to NMAC (a fully analyzed variant of HMAC) and HMAC algorithms and NMAC/HMAC versions of some recently proposed hash and compression function modes. We show that the recently proposed BNMAC and KMDP MAC schemes are even weaker than NMAC...

  3. Performance evaluation of Grain family and Espresso ciphers for applications on resource constrained devices

    Directory of Open Access Journals (Sweden)

    Subhrajyoti Deb

    2018-03-01

    Full Text Available A secure stream cipher is an effective security solution for applications running on resource-constrained devices. The Grain family of stream ciphers (Grain v1, Grain-128, and Grain-128a is a family of stream ciphers designed for low-end devices. Similarly, Espresso is a lightweight stream cipher that was developed recently for 5G wireless mobile communication. The randomness of the keystream produced by a stream cipher is a good indicator of its security strength. In this study, we have analyzed the randomness properties of the keystreams produced by both the Grain Family and Espresso ciphers using the statistical packages DieHarder and NIST STS. We also analyzed their performances in two constrained devices (ATmega328P and ESP8266 based on three attainable parameters, namely computation time, memory, and power consumption. Keywords: Stream cipher, Randomness, Dieharder, NIST STS

  4. Determination of total fluorine in five coal reference materials by proton-induced gamma-ray emission spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Roelandts, I.; Robaye, G.; Delbrouck-Habaru, J.M.; Weber, G. [University of Liege, Sart (Belgium). Dept. of Geology, Petrology and Geochemistry

    1996-03-01

    The direct non-destructive proton-induced gamma-ray emission (PIGE) technique with a germanium detector was applied to the determination of total fluorine concentration in five coal reference materials (BCR 30, NIST 1632b, NIST 1635, SARM 20 and USGS CLB-1). Duplicate analyses were made from five randomly selected bottles of each coal. Individual data are presented and some problems (calibration, proton stopping power, effects of sample heating by the proton beam, background estimation) which were encountered during this study are discussed. Sensitivity and reproducibility of the determinations, and homogeneity of the coal samples with respect to fluorine contents by analysis of variance were investigated. The present data are also compared with the few published values for these reference samples, including other PIGE data. The use of synthetic standards and spiked samples in the present study suggested that the PIGE method was more accurate than other techniques.

  5. Research ethics for clinical researchers.

    Science.gov (United States)

    Harnett, John D; Neuman, Richard

    2015-01-01

    This chapter describes the history of the development of modern research ethics. The governance of research ethics is discussed and varies according to geographical location. However, the guidelines used for research ethics review are very similar across a wide variety of jurisdictions. The paramount importance of protecting the privacy and confidentiality of research participants is discussed at length. Particular emphasis is placed on the process of informed consent, and step-by-step practical guidelines are described. The issue of research in vulnerable populations is touched upon and guidelines are provided. Practical advice is provided for researchers to guide their interactions with research ethics boards. Issues related to scientific misconduct and research fraud are not dealt with in this paper.

  6. Original Research Original Research

    African Journals Online (AJOL)

    RAGHAVENDRA

    To this effect, two basic research with these research ... In this area, Ho conducted a research on a topic “Effectiveness o .... questioning, making a list, clustering, preparing a scratch .... three data collection instruments by using quantitative and.

  7. Spectral responsivity-based calibration of photometer and colorimeter standards

    Science.gov (United States)

    Eppeldauer, George P.

    2013-08-01

    Several new generation transfer- and working-standard illuminance meters and tristimulus colorimeters have been developed at the National Institute of Standards and Technology (NIST) [1] to measure all kinds of light sources with low uncertainty. The spectral and broad-band (illuminance) responsivities of the photometer (Y) channels of two tristimulus meters were determined at both the Spectral Irradiance and Radiance Responsivity Calibrations using Uniform Sources (SIRCUS) facility and the Spectral Comparator Facility (SCF) [2]. The two illuminance responsivities agreed within 0.1% with an overall uncertainty of 0.2% (k = 2), which is a factor of two improvement over the present NIST photometric scale. The first detector-based tristimulus color scale [3] was realized. All channels of the reference tristimulus colorimeter were calibrated at the SIRCUS. The other tristimulus meters were calibrated at the SCF and also against the reference meter on the photometry bench in broad-band measurement mode. The agreement between detector- and source-based calibrations was within 3 K when a tungsten lamp-standard was measured at 2856 K and 3100 K [4]. The color-temperature uncertainty of tungsten lamp measurements was 4 K (k = 2) between 2300 K and 3200 K, which is a factor of two improvement over the presently used NIST source-based color temperature scale. One colorimeter was extended with an additional (fifth) channel to apply software implemented matrix corrections. With this correction, the spectral mismatch caused color difference errors were decreased by a factor of 20 for single-color LEDs.

  8. Ultrasonic slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry for the determination of Cr, Fe, Cu, Zn and Se in cereals

    Science.gov (United States)

    Huang, Shih-Yi; Jiang, Shiuh-Jen; Sahayam, A. C.

    2014-11-01

    Ultrasonic slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry (USS-ETV-ICP-MS) has been applied to determine Cr, Fe, Cu, Zn and Se in several cereal samples. Thioacetamide was used as the modifier to enhance the ion signals. The background ions at the masses of interest were reduced in intensity significantly by using 1.0 mL min- 1 methane (CH4) as reaction cell gas in the dynamic reaction cell (DRC). Since the sensitivities of Cr, Fe, Cu, Zn and Se in different matrices were quite different, standard addition and isotope dilution methods were used for the determination of Cr, Fe, Cu, Zn and Se in these cereal samples. The method detection limits estimated from standard addition curves were about 1, 10, 4, 12 and 2 ng g- 1 for Cr, Fe, Cu, Zn and Se, respectively, in original cereal samples. This procedure has been applied to the determination of Cr, Fe, Cu, Zn and Se whose concentrations are in μg g- 1 (except Cr and Se) in standard reference materials (SRM) of National institute of standards and technology (NIST), NIST SRM 1568a Rice Flour and NIST SRM 1567a Wheat Flour and two cereal samples purchased from a local market. The analysis results of reference materials agreed with certified values at 95% confidence level according to Student's T-test. The results for the real world cereal samples were also found to be in good agreement with the pneumatic nebulization DRC ICP-MS results of the sample solutions.

  9. Simultaneous determination of macronutrients, micronutrients and trace elements in mineral fertilizers by inductively coupled plasma optical emission spectrometry

    Science.gov (United States)

    de Oliveira Souza, Sidnei; da Costa, Silvânio Silvério Lopes; Santos, Dayane Melo; dos Santos Pinto, Jéssica; Garcia, Carlos Alexandre Borges; Alves, José do Patrocínio Hora; Araujo, Rennan Geovanny Oliveira

    2014-06-01

    An analytical method for simultaneous determination of macronutrients (Ca, Mg, Na and P), micronutrients (Cu, Fe, Mn and Zn) and trace elements (Al, As, Cd, Pb and V) in mineral fertilizers was optimized. Two-level full factorial design was applied to evaluate the optimal proportions of reagents used in the sample digestion on hot plate. A Doehlert design for two variables was used to evaluate the operating conditions of the inductively coupled plasma optical emission spectrometer in order to accomplish the simultaneous determination of the analyte concentrations. The limits of quantification (LOQs) ranged from 2.0 mg kg- 1 for Mn to 77.3 mg kg- 1 for P. The accuracy and precision of the proposed method were evaluated by analysis of standard reference materials (SRMs) of Western phosphate rock (NIST 694), Florida phosphate rock (NIST 120C) and Trace elements in multi-nutrient fertilizer (NIST 695), considered to be adequate for simultaneous determination. Twenty-one samples of mineral fertilizers collected in Sergipe State, Brazil, were analyzed. For all samples, the As, Ca, Cd and Pb concentrations were below the LOQ values of the analytical method. For As, Cd and Pb the obtained LOQ values were below the maximum limit allowed by the Brazilian Ministry of Agriculture, Livestock and Food Supply (Ministério da Agricultura, Pecuária e Abastecimento - MAPA). The optimized method presented good accuracy and was effectively applied to quantitative simultaneous determination of the analytes in mineral fertilizers by inductively coupled plasma optical emission spectrometry (ICP OES).

  10. Preliminary assessment of trace elements effects on essential oil production of Melissa officinalis L. (Lemon balm)

    International Nuclear Information System (INIS)

    Sussa, Fabio V.; Duarte, Celina L.; Andrade, Luana S.; Silva, Paulo S.C.; Furlan, Marcos R.

    2013-01-01

    Melissa officinalis L., Lemon balm, (Lamiaceae) is an herb used as medicine, condiment and in the cosmetic and perfumery industry due to its essential oil. In this study a preliminary assessment of trace elements effects on essential oil production was performed in order to verify an improvement in its quality. The Melissa officinalis samples were harvested from three different soil sites localized in Ibirapuera Park, São Paulo, Brazil. Elemental concentration for the elements As, Ba, Br, Ce, Cl, Co, Cr, Cs, Eu, Fe, Hf, K, La, Lu, Mg, Mn, Na, Nd, Rb, Sb, Sc, Se, Sm, Ta, Tb, Ti, Th, U, V, Yb, Zn and Zr was determined by Instrumental Neutron Activation Analysis (INAA) in Melissa officinalis leaves and surrounding soil. The essential oil was extracted from its leaves by hydrodistillation process in Clevenger apparatus and analyzed by gas chromatography coupled to a mass spectrometer (GC-MS). Certified reference materials NIST SRM-1515 Apple Leaves, NIST SRM-1547 Peach Leaves and NIST SRM-1573a Tomato Leaves were analyzed for quality control. Our results showed Geranial and Neral were identified as the major compounds in the essential oil extracted from Melissa officinalis L. for all collected sites. However, the relative proportion of some chemical constituents was altered according to the site collected. The preliminary results showed that the production of essential oil by Melissa officinalis must be positively correlated with the concentrations of Rb, Zn and negatively correlated with Sc, Mn, La, K, Fe, and Cr. (author)

  11. Preliminary assessment of trace elements effects on essential oil production of Melissa officinalis L. (Lemon balm)

    Energy Technology Data Exchange (ETDEWEB)

    Sussa, Fabio V.; Duarte, Celina L.; Andrade, Luana S.; Silva, Paulo S.C., E-mail: pscsilva@ipen.br, E-mail: clduarte@ipen.br, E-mail: fabiosussa@uol.com.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Furlan, Marcos R., E-mail: furlanagro@gmail.com [Universidade de Taubate, SP (Brazil). Departamento de Ciencias Agrarias

    2013-07-01

    Melissa officinalis L., Lemon balm, (Lamiaceae) is an herb used as medicine, condiment and in the cosmetic and perfumery industry due to its essential oil. In this study a preliminary assessment of trace elements effects on essential oil production was performed in order to verify an improvement in its quality. The Melissa officinalis samples were harvested from three different soil sites localized in Ibirapuera Park, São Paulo, Brazil. Elemental concentration for the elements As, Ba, Br, Ce, Cl, Co, Cr, Cs, Eu, Fe, Hf, K, La, Lu, Mg, Mn, Na, Nd, Rb, Sb, Sc, Se, Sm, Ta, Tb, Ti, Th, U, V, Yb, Zn and Zr was determined by Instrumental Neutron Activation Analysis (INAA) in Melissa officinalis leaves and surrounding soil. The essential oil was extracted from its leaves by hydrodistillation process in Clevenger apparatus and analyzed by gas chromatography coupled to a mass spectrometer (GC-MS). Certified reference materials NIST SRM-1515 Apple Leaves, NIST SRM-1547 Peach Leaves and NIST SRM-1573a Tomato Leaves were analyzed for quality control. Our results showed Geranial and Neral were identified as the major compounds in the essential oil extracted from Melissa officinalis L. for all collected sites. However, the relative proportion of some chemical constituents was altered according to the site collected. The preliminary results showed that the production of essential oil by Melissa officinalis must be positively correlated with the concentrations of Rb, Zn and negatively correlated with Sc, Mn, La, K, Fe, and Cr. (author)

  12. 256-pixel microcalorimeter array for high-resolution γ-ray spectroscopy of mixed-actinide materials

    Energy Technology Data Exchange (ETDEWEB)

    Winkler, R., E-mail: rwinkler@lanl.gov [Los Alamos National Laboratory, Los Alamos, NM (United States); Hoover, A.S.; Rabin, M.W. [Los Alamos National Laboratory, Los Alamos, NM (United States); Bennett, D.A.; Doriese, W.B.; Fowler, J.W.; Hays-Wehle, J.; Horansky, R.D.; Reintsema, C.D.; Schmidt, D.R.; Vale, L.R.; Ullom, J.N. [National Institute of Standards and Technology, Boulder, CO (United States)

    2015-01-11

    The application of cryogenic microcalorimeter detectors to γ-ray spectroscopy allows for measurements with unprecedented energy resolution. These detectors are ideally suited for γ-ray spectroscopy applications for which the measurement quality is limited by the spectral overlap of many closely spaced transitions using conventional detector technologies. The non-destructive analysis of mixed-isotope Pu materials is one such application where the precision can be potentially improved utilizing microcalorimeter detectors compared to current state-of-the-art high-purity Ge detectors (HPGe). The LANL-NIST γ-ray spectrometer, a 256-pixel microcalorimeter array based on transition-edge sensors (TESs), was recently commissioned and used to collect data on a variety of Pu isotopic standards to characterize the instrument performance. These measurements represent the first time the simultaneous readout of all 256 pixels for measurements of mixed-isotope Pu materials has been achieved. The LANL-NIST γ-ray spectrometer has demonstrated an average pixel resolution of 55 eV full-width-at-half-maximum at 100 keV, nearly an order of magnitude better than HPGe detectors. Some challenges of the analysis of many-channel ultra-high resolution data and the techniques used to produce quality spectra for isotopic analysis will be presented. The LANL-NIST γ-ray spectrometer has also demonstrated stable operation and obtained high resolution measurements at total array event rates beyond 1 kHz. For a total event rate of 1.25 kHz, approximately 5.6 cps/pixel, a 72.2 eV average FWHM for the 103 keV photopeak of {sup 153}Gd was achieved.

  13. Cryptanalysis of Vortex

    DEFF Research Database (Denmark)

    Aumasson, Jean-Philippe; Dunkelman, Orr; Mendel, Florian

    2009-01-01

    Vortex is a hash function that was first presented at ISC'2008, then submitted to the NIST SHA-3 competition after some modifications. This paper describes several attacks on both versions of Vortex, including collisions, second preimages, preimages, and distinguishers. Our attacks exploit flaws...

  14. Annotation of Heterogeneous Multimedia Content Using Automatic Speech Recognition

    NARCIS (Netherlands)

    Huijbregts, M.A.H.; Ordelman, Roeland J.F.; de Jong, Franciska M.G.

    2007-01-01

    This paper reports on the setup and evaluation of robust speech recognition system parts, geared towards transcript generation for heterogeneous, real-life media collections. The system is deployed for generating speech transcripts for the NIST/TRECVID-2007 test collection, part of a Dutch real-life

  15. Word Transition Entropy as an Indicator for Expected Machine Translation Quality

    DEFF Research Database (Denmark)

    Carl, Michael; Schaeffer, Moritz

    2014-01-01

    While most machine translation evaluation techniques (BLEU, NIST, TER, METEOR) assess translation quality based on a set of reference translations, we suggest to evaluate the literality of a set of (human or machine generated) translations to infer their potential quality. We provide evidence whi...

  16. 77 FR 70792 - Privacy Act of 1974; Department of Homeland Security/ALL-004 General Information Technology...

    Science.gov (United States)

    2012-11-27

    ... agency to publish in the Federal Register a description denoting the type and character of each system of... DHS IT resources; IP address of access; Logs of Internet activity; and Records on the authentication... and Technology (NIST) Security Standards from Authentication to Certification and Accreditation...

  17. 77 FR 20789 - Work Group on Measuring Systems for Taxis

    Science.gov (United States)

    2012-04-06

    ... DEPARTMENT OF COMMERCE National Institute of Standards and Technology Work Group on Measuring.... SUMMARY: The National Institute of Standards and Technology (NIST) is forming a Work Group (WG) to develop... states in laws, regulations, methods, and testing equipment that comprises the regulatory control of...

  18. Low-Cost Ultra-Wideband EM Sensor for UXO Detection and Classification

    Science.gov (United States)

    2012-04-01

    Mechanical System MOTU Mark of the Unicorn – a brand name for audio equipment MR Magneto-Resistance NIST National Institute of Standards and...magnetic surveys are able to detect ferrous bodies at a further distance than EMI measurements. Consequently , the magnetic anomaly is broader

  19. 75 FR 16748 - Final Voluntary Product Standard; DOC PS 20-10 “American Softwood Lumber Standard”

    Science.gov (United States)

    2010-04-02

    ...-0146-02] Final Voluntary Product Standard; DOC PS 20-10 ``American Softwood Lumber Standard'' AGENCY... of Standards and Technology (NIST) announces voluntary product standard DOC PS 20-10 ``American Softwood Lumber Standard'' which will supersede DOC PS 20-05. The Standard establishes standard sizes and...

  20. Acceptance Factors Influencing Adoption of National Institute of Standards and Technology Information Security Standards: A Quantitative Study

    Science.gov (United States)

    Kiriakou, Charles M.

    2012-01-01

    Adoption of a comprehensive information security governance model and security controls is the best option organizations may have to protect their information assets and comply with regulatory requirements. Understanding acceptance factors of the National Institute of Standards and Technology (NIST) Risk Management Framework (RMF) comprehensive…