WorldWideScience

Sample records for repeated measures results

  1. Analysis of repeated measures data

    CERN Document Server

    Islam, M Ataharul

    2017-01-01

    This book presents a broad range of statistical techniques to address emerging needs in the field of repeated measures. It also provides a comprehensive overview of extensions of generalized linear models for the bivariate exponential family of distributions, which represent a new development in analysing repeated measures data. The demand for statistical models for correlated outcomes has grown rapidly recently, mainly due to presence of two types of underlying associations: associations between outcomes, and associations between explanatory variables and outcomes. The book systematically addresses key problems arising in the modelling of repeated measures data, bearing in mind those factors that play a major role in estimating the underlying relationships between covariates and outcome variables for correlated outcome data. In addition, it presents new approaches to addressing current challenges in the field of repeated measures and models based on conditional and joint probabilities. Markov models of first...

  2. Measurement-based quantum repeaters

    CERN Document Server

    Zwerger, M; Briegel, H J

    2012-01-01

    We introduce measurement-based quantum repeaters, where small-scale measurement-based quantum processors are used to perform entanglement purification and entanglement swapping in a long-range quantum communication protocol. In the scheme, pre-prepared entangled states stored at intermediate repeater stations are coupled with incoming photons by simple Bell-measurements, without the need of performing additional quantum gates or measurements. We show how to construct the required resource states, and how to minimize their size. We analyze the performance of the scheme under noise and imperfections, with focus on small-scale implementations involving entangled states of few qubits. We find measurement-based purification protocols with significantly improved noise thresholds. Furthermore we show that already resource states of small size suffice to significantly increase the maximal communication distance. We also discuss possible advantages of our scheme for different set-ups.

  3. Effects of repeatability measures on results of fMRI sICA: a study on simulated and real resting-state effects.

    Science.gov (United States)

    Remes, Jukka J; Starck, Tuomo; Nikkinen, Juha; Ollila, Esa; Beckmann, Christian F; Tervonen, Osmo; Kiviniemi, Vesa; Silven, Olli

    2011-05-15

    Spatial independent components analysis (sICA) has become a widely applied data-driven method for fMRI data, especially for resting-state studies. These sICA approaches are often based on iterative estimation algorithms and there are concerns about accuracy due to noise. Repeatability measures such as ICASSO, RAICAR and ARABICA have been introduced as remedies but information on their effects on estimates is limited. The contribution of this study was to provide more of such information and test if the repeatability analyses are necessary. We compared FastICA-based ordinary and repeatability approaches concerning mixing vector estimates. Comparisons included original FastICA, FSL4 Melodic FastICA and original and modified ICASSO. The effects of bootstrapping and convergence threshold were evaluated. The results show that there is only moderate improvement due to repeatability measures and only in the bootstrapping case. Bootstrapping attenuated power from time courses of resting-state network related ICs at frequencies higher than 0.1 Hz and made subsets of low frequency oscillations more emphasized IC-wise. The convergence threshold did not have a significant role concerning the accuracy of estimates. The performance results suggest that repeatability measures or strict converge criteria might not be needed in sICA analyses of fMRI data. Consequently, the results in existing sICA fMRI literature are probably valid in this sense. A decreased accuracy of original bootstrapping ICASSO was observed and corrected by using centrotype mixing estimates but the results warrant for thorough evaluations of data-driven methods in general. Also, given the fMRI-specific considerations, further development of sICA methods is strongly encouraged. Copyright © 2010 Elsevier Inc. All rights reserved.

  4. Analysis of repeated outcome measures from longitudinal studies

    Institute of Scientific and Technical Information of China (English)

    Yuanjia WANG; Naihua DUAN

    2011-01-01

    @@ In many clinical studies repeated measurements of an outcome are collected over time.For example,in an 8-week study of treatment for obsessive compulsive disorder,the severity of the disorder may be measured weekly using the Yale-Brown-Obsessive-Compulsive-Disorder-Scale (YBOCS).For each study participant who completes the study,there will be nine repeated measures of YBOCS (a baseline assessment plus eight assessments during the course of treatment).Such a study in which participants are followed and measured repeatedly over time is called a longitudinal study and the resulting data are called longitudinal data.

  5. Multivariate linear models and repeated measurements revisited

    DEFF Research Database (Denmark)

    Dalgaard, Peter

    2009-01-01

    Methods for generalized analysis of variance based on multivariate normal theory have been known for many years. In a repeated measurements context, it is most often of interest to consider transformed responses, typically within-subject contrasts or averages. Efficiency considerations leads...

  6. On balanced minimal repeated measurements designs

    Directory of Open Access Journals (Sweden)

    Shakeel Ahmad Mir

    2014-10-01

    Full Text Available Repeated Measurements designs are concerned with scientific experiments in which each experimental unit is assigned more than once to a treatment either different or identical. This class of designs has the property that the unbiased estimators for elementary contrasts among direct and residual effects are obtainable. Afsarinejad (1983 provided a method of constructing balanced Minimal Repeated Measurements designs p < t , when t is an odd or prime power, one or more than one treatment may occur more than once in some sequences and  designs so constructed no longer remain uniform in periods. In this paper an attempt has been made to provide a new method to overcome this drawback. Specifically, two cases have been considered                RM[t,n=t(t-t/(p-1,p], λ2=1 for balanced minimal repeated measurements designs and  RM[t,n=2t(t-t/(p-1,p], λ2=2 for balanced  repeated measurements designs. In addition , a method has been provided for constructing              extra-balanced minimal designs for special case RM[t,n=t2/(p-1,p], λ2=1.

  7. Nonparametric additive regression for repeatedly measured data

    KAUST Repository

    Carroll, R. J.

    2009-05-20

    We develop an easily computed smooth backfitting algorithm for additive model fitting in repeated measures problems. Our methodology easily copes with various settings, such as when some covariates are the same over repeated response measurements. We allow for a working covariance matrix for the regression errors, showing that our method is most efficient when the correct covariance matrix is used. The component functions achieve the known asymptotic variance lower bound for the scalar argument case. Smooth backfitting also leads directly to design-independent biases in the local linear case. Simulations show our estimator has smaller variance than the usual kernel estimator. This is also illustrated by an example from nutritional epidemiology. © 2009 Biometrika Trust.

  8. Assessing agreement with repeated measures for random observers.

    Science.gov (United States)

    Chen, Chia-Cheng; Barnhart, Huiman X

    2011-12-30

    Agreement studies are often concerned with assessing whether different observers for measuring responses on the same subject or sample can produce similar results. The concordance correlation coefficient (CCC) is a popular index for assessing the closeness among observers for quantitative measurements. Usually, the CCC is used for data without and with replications based on subject and observer effects only. However, we cannot use this methodology if repeated measurements rather than replications are collected. Although there exist some CCC-type indices for assessing agreement with repeated measurements, there is no CCC for random observers and random time points. In this paper, we propose a new CCC for repeated measures where both observers and time points are treated as random effects. A simulation study demonstrates our proposed methodology, and we use vertebral body data and image data for illustrations.

  9. Repeated measurement sampling in genetic association analysis with genotyping errors.

    Science.gov (United States)

    Lai, Renzhen; Zhang, Hong; Yang, Yaning

    2007-02-01

    Genotype misclassification occurs frequently in human genetic association studies. When cases and controls are subject to the same misclassification model, Pearson's chi-square test has the correct type I error but may lose power. Most current methods adjusting for genotyping errors assume that the misclassification model is known a priori or can be assessed by a gold standard instrument. But in practical applications, the misclassification probabilities may not be completely known or the gold standard method can be too costly to be available. The repeated measurement design provides an alternative approach for identifying misclassification probabilities. With this design, a proportion of the subjects are measured repeatedly (five or more repeats) for the genotypes when the error model is completely unknown. We investigate the applications of the repeated measurement method in genetic association analysis. Cost-effectiveness study shows that if the phenotyping-to-genotyping cost ratio or the misclassification rates are relatively large, the repeat sampling can gain power over the regular case-control design. We also show that the power gain is not sensitive to the genetic model, genetic relative risk and the population high-risk allele frequency, all of which are typically important ingredients in association studies. An important implication of this result is that whatever the genetic factors are, the repeated measurement method can be applied if the genotyping errors must be accounted for or the phenotyping cost is high.

  10. Conservative Sample Size Determination for Repeated Measures Analysis of Covariance.

    Science.gov (United States)

    Morgan, Timothy M; Case, L Douglas

    2013-07-05

    In the design of a randomized clinical trial with one pre and multiple post randomized assessments of the outcome variable, one needs to account for the repeated measures in determining the appropriate sample size. Unfortunately, one seldom has a good estimate of the variance of the outcome measure, let alone the correlations among the measurements over time. We show how sample sizes can be calculated by making conservative assumptions regarding the correlations for a variety of covariance structures. The most conservative choice for the correlation depends on the covariance structure and the number of repeated measures. In the absence of good estimates of the correlations, the sample size is often based on a two-sample t-test, making the 'ultra' conservative and unrealistic assumption that there are zero correlations between the baseline and follow-up measures while at the same time assuming there are perfect correlations between the follow-up measures. Compared to the case of taking a single measurement, substantial savings in sample size can be realized by accounting for the repeated measures, even with very conservative assumptions regarding the parameters of the assumed correlation matrix. Assuming compound symmetry, the sample size from the two-sample t-test calculation can be reduced at least 44%, 56%, and 61% for repeated measures analysis of covariance by taking 2, 3, and 4 follow-up measures, respectively. The results offer a rational basis for determining a fairly conservative, yet efficient, sample size for clinical trials with repeated measures and a baseline value.

  11. Positional Repeatability Measurements Of Stepper Motors At Cryogenic Temperatures

    Science.gov (United States)

    Pompea, Stephen M.; Hall, Michael S.; Bartko, Frank; Houck, James R.

    1983-08-01

    Stepper motors operating at liquid helium temperature have multiple applications in cryogenically-cooled telescopes such as the Shuttle Infrared Telescope Facility (SIRTF). These SIRTF applications include driving cryogen flow valves, operating the Multiple Instrument Chamber (MIC) beam splitter mechanism, and operating filters and grating wheel mechanisms in the scientific instruments. The positional repeatability of the beam splitter drive mechanism is especially critical since it feeds the optical beam to the scien-tific instruments. Despite these important applications, no significant data on the positional repeatability of stepper motors at cryogenic temperatures has been available. Therefore, we conducted a series of measurements to determine the positional repeatability of a modified, off-the-shelf Berger/Lahr stepper motor (model RDM 253/25, step angle 3.6°) which had demonstrated excellent performance in previous endurance testing at LHe temperature. These test results indicated that the positional repeatability of the motor was excellent at all temperatures, with somewhat better performance at cryogenic temperatures. Another important result was that the motor could be repeatedly turned off and on while still accurately retaining its rotor position.

  12. Repeated nondiagnostic result of thyroid fine-needle aspiration biopsy.

    Science.gov (United States)

    Ziemiańska, Klaudia; Kopczyński, Janusz; Kowalska, Aldona

    2016-01-01

    Fine-needle aspiration biopsy (FNAB) is the most accurate and cost-effective method to evaluate the risk of malignancy of thyroid nodules, but approximately 1-24% of FNABs generate a nondiagnostic result (ND-FNAB). The aim of this study was to determine the predictive factors of a repeated nondiagnostic result of FNAB. A total of 4018 FNABs performed in a territorial referral centre were analysed, of which 288 (7.17%) were nondiagnostic. Medical records were available for 245 biopsies performed in 228 patients. The retrospective analysis of factors that may influence a repeat ND-FNAB, including demographic, clinical and ultrasound characteristics, was performed. A repeat FNAB was performed in 159 nodules giving a diagnostic result in 79.2% of cases. The time between the biopsies ranged from 1 to 611 days (mean 154.4, median 119). The timing of a repeat FNAB did not significantly alter the diagnostic output (p = 0.29). In the univariate analysis, significant predictors of a repeat ND-FNAB were older patient age (p = 0.02), L-thyroxine supplementation (p = 0.05), and a history of (131)I therapy (p < 0.0001). In the multivariate analysis, only a history of (131)I therapy was a statistically significant risk factor for a repeat ND-FNAB (p = 0.002). Patients with a history of (131)I therapy and ND-FNAB should undergo periodic ultrasonographic assessment rather than a repeat biopsy. The interval between repeated FNABs recommended by guidelines does not affect the diagnostic output.

  13. Bayesian model selection of informative hypotheses for repeated measurements

    NARCIS (Netherlands)

    Mulder, Joris; Klugkist, I.G.; Schoot, Rens van de; Meeus, W.H.J.; Selfhout, Maarten; Hoijtink, Herbert

    2010-01-01

    When analyzing repeated measurements data, researchers often have expectations about the relations between the measurement means. The expectations can often be formalized using equality and inequality constraints between (i) the measurement means over time, (ii) the measurement means between

  14. Bayesian model selection of informative hypotheses for repeated measurements

    NARCIS (Netherlands)

    Mulder, J.|info:eu-repo/dai/nl/304823031; Klugkist, I.G.|info:eu-repo/dai/nl/27330089X; Van de Schoot, R.|info:eu-repo/dai/nl/304833207; Meeus, W.H.J.|info:eu-repo/dai/nl/070442215; van Zalk, M.H.W.|info:eu-repo/dai/nl/304836214; Hoijtink, H.J.A.|info:eu-repo/dai/nl/075184427

    2009-01-01

    When analyzing repeated measurements data, researchers often have expectations about the relations between the measurement means. The expectations can often be formalized using equality and inequality constraints between (i) the measurement means over time, (ii) the measurement means between groups,

  15. Repeated vitrification/warming of human sperm gives better results than repeated slow programmable freezing

    Institute of Scientific and Technical Information of China (English)

    Teraporn Vutyavanich; Worashorn Lattiwongsakorn; Waraporn Piromlertamorn; Sudarat Samchimchom

    2012-01-01

    In this study,we compared the effects of repeated freezing/thawing of human sperm by our in-house method of rapid freezing with slow programmable freezing.Sperm samples from 11 normozoospermic subjects were processed through density gradients and divided into three aliquots:non-frozen,rapid freezing and slow programmable freezing.Sperm in the rapid freezing group had better motility and viability than those in the slow freezing group (P<O.01) after the first,second and third cycles of freezing/thawing,but there was no difference in morphology.In the second experiment,rapid freezing was repeated three times in 20 subjects.The samples from each thawing cycle were evaluated for DNA fragmentation using the alkaline comet assay.DNA fragmentation began to increase considerably after the second cycle of freezing/thawing,but to a level that was not clinically important.In the third experiment,rapid freezing was done repeatedly in 10 subjects,until no motile sperm were observed after thawing.The median number of repeated freezing/thawing that yielded no motile sperm was seven (range:5-8,mean:6.8).In conclusion,we demonstrated that repeated freezing/thawing of processed semen using our rapid freezing method gave better results than standard slow programmable freezing.This method can help maximize the usage of precious cryopreserved sperm samples in assisted reproduction technology.

  16. Capturing learning effects on eye movements in repeated measures experiments

    DEFF Research Database (Denmark)

    Bagger, Martin; Orquin, Jacob Lund; Fiedler, Susann

    We propose and illustrate that repeated exposure to stimuli sets increases the size of the saccade amplitudes. Saccadic amplitudes are closely related to the perceptual span and therefore used as a measure for the information intake in an experiment. Studies on expertise have shown that experts...... experiment in which 68 participants made choices between four alternatives with three different between subject conditions varying in presentation format (verbal matrix, a pictorial matrix, and a realistic product representation). The results consistently demonstrate an increase of the saccade amplitude over...... the course of the experiment independent of condition. We conclude by discussing our results in the light of the possible increase of the perceptual span and its implications for the research procedure in eye-tracking experiments with a repeated measurement design....

  17. Airborne Repeat Pass Interferometry for Deformation Measurements

    NARCIS (Netherlands)

    Groot, J.; Otten, M.; Halsema, E. van

    2000-01-01

    In ground engineering the need for deformation measurements is urgent. SAR interferometry can be used to measure small (sub-wavelength) deformations. An experiment to investigate this for dike deformations was set up, using the C-band SAR system PHARUS (PHased ARray Universal SAR). This paper descri

  18. Discriminant analysis for repeated measures data: a review

    Directory of Open Access Journals (Sweden)

    Lisa Lix

    2010-09-01

    Full Text Available Discriminant analysis (DA encompasses procedures for classifying observations into groups (i.e., predictive discriminative analysis and describing the relative importance of variables for distinguishing amongst groups (i.e., descriptive discriminative analysis. In recent years, a number of developments have occurred in DA procedures for the analysis of data from repeated measures designs. Specifically, DA procedures have been developed for repeated measures data characterized by missing observations and/or unbalanced measurement occasions, as well as high-dimensional data in which measurements are collected repeatedly on two or more variables. This paper reviews the literature on DA procedures for univariate and multivariate repeated measures data, focusing on covariance pattern and linear mixed-effects models. A numeric example illustrates their implementation using SAS software.

  19. Unitarity, Feedback, Interactions -- Dynamics Emergent from Repeated Measurements

    CERN Document Server

    Altamirano, Natacha; Mann, Robert B; Zych, Magdalena

    2016-01-01

    Motivated by the recent efforts to describe the gravitational interaction as a classical channel arising from continuous quantum measurements, we study what types of dynamics can emerge from a model of repeated short interactions of a system with a set of ancillae. We show that contingent on the model parameters the resulting dynamics ranges from exact unitarity to arbitrary fast decoherence (quantum Zeno effect). For a series of measurements the effective dynamics includes feedback-control, which for a composite system yields effective interactions between the subsystems. We quantify the amount of decoherence accompanying such induced interactions, generalizing the lower bound of the gravitational example. However, by allowing multipartite measurements, the interactions can be induced with arbitrary low decoherence. Our results have implications for gravity-inspired decoherence models and the simple framework used in the present study can find applications in devising novel quantum control protocols, or quan...

  20. Stability of parameters in repeated TVA measures

    DEFF Research Database (Denmark)

    Sørensen, Thomas Alrik

    Several recent studies have explored the limitations of human visual short-term memory or VSTM (e.g. Luck & Vogel, 1997; Wheeler & Treisman, 2002; Alvarez & Cavanagh, 2004). Usually researchers agree that VSTM is limited to a capacity of about 3 to 4 objects at any given moment (Cowan, 2001......). Capacity of short-term memory is measured in a range of studies often using the change detection paradigm (CD). However, the whole report paradigm (WR) may be a more reliable paradigm (Cusack, Lehmann, Veldsman, & Mitchell, 2009). Moreover, each individual WR trial yield more information compared to a CD...

  1. Correct use of repeated measures analysis of variance.

    Science.gov (United States)

    Park, Eunsik; Cho, Meehye; Ki, Chang-Seok

    2009-02-01

    In biomedical research, researchers frequently use statistical procedures such as the t-test, standard analysis of variance (ANOVA), or the repeated measures ANOVA to compare means between the groups of interest. There are frequently some misuses in applying these procedures since the conditions of the experiments or statistical assumptions necessary to apply these procedures are not fully taken into consideration. In this paper, we demonstrate the correct use of repeated measures ANOVA to prevent or minimize ethical or scientific problems due to its misuse. We also describe the appropriate use of multiple comparison tests for follow-up analysis in repeated measures ANOVA. Finally, we demonstrate the use of repeated measures ANOVA by using real data and the statistical software package SPSS (SPSS Inc., USA).

  2. RESULTS OF SLICE MEASUREMENTS

    CERN Document Server

    Rudolph, J

    2011-01-01

    The linear accelerator ELBE delivers high-brightness electron bunches to multiple user stations, including two IR-FEL oscillators [1], [2]. In the framework of an upgrade program the current thermionic injector is being replaced by a SRF-photoinjector [3], [4]. The SRF injector promises higher beam quality, especially required for future experiments with high power laser radiation. During the commissioning phase, the SRF-injector was running in parallel to the thermionic gun. After installation of a injection beamline (dogleg), beam from the SRF-injector can now be injected into the ELBE linac. Detailed characterization of the electron beam quality delivered by the new electron injector includes vertical slice emittance measurements in addition to measurements of projected emittance values. This report gives an overview of the status of the project and summarizes first measurement results as well as results of simulations performed with measurement settings.

  3. Coseismic and postseismic velocity changes measured by repeating earthquakes

    Science.gov (United States)

    Schaff, David P.; Beroza, Gregory C.

    2004-10-01

    Repeating earthquakes that rupture approximately the same fault patch and have nearly identical waveforms are a useful tool for measuring temporal changes in wave propagation in the Earth's crust. Since source and path effects are common to all earthquakes in a repeating earthquake sequence (multiplet), differences in their waveforms can be attributed to changes in the characteristics of the medium. We have identified over 20 multiplets containing between 5 and 40 repeating events in the aftershock zones of the 1989 Loma Prieta and 1984 Morgan Hill, California, earthquakes. Postmain shock events reveal delays of phases in the early S wave coda of as much as 0.2 s relative to premain shock events. The delay amounts to a path-averaged coseismic velocity decrease of about 1.5% for P waves and 3.5% for S waves. Since most of the multiplets are aftershocks and follow Omori's law, we have excellent temporal sampling in the immediate postmain shock period. We find that the amplitude of the velocity decrease decays logarithmically in time following the main shock. In some cases it returns to the premain shock values, while in others it does not. Similar results are obtained for the Morgan Hill main shock. Because the fractional change in S wave velocity is greater than the fractional change in P wave velocity, it suggests that the opening or connection of fluid-filled fractures is the underlying cause. The magnitude of the velocity change implies that low effective pressures are present in the source region of the velocity change. Our results suggest that the changes are predominantly near the stations and shallow, but we cannot exclude the possibility that changes occur at greater depth as well. If the variations are shallow, we may be detecting the lingering effects of nonlinearity during main shock strong ground motion. If the variations are deep, it suggests that pore pressures at seismogenic depths are high, which would likely play a key role in the earthquake process.

  4. Repeated High-Precision Gravity and GPS Measurement Techniques

    Science.gov (United States)

    Gettings, P.; Harris, R. N.; Allis, R.; Chapman, D. S.

    2003-12-01

    Repeated high-precision gravity and GPS measurements are becoming a common tool for tracking changes in subsurface reservoirs. Despite this, there is little literature which discusses measurement techniques and the expected errors. Our research has focused on improving measurement techniques to be applied to ground water and geothermal steam reservoirs, including quantifying the minimum error levels with modern equipment. We applied these methods in two studies: ground water monitoring of the southern Salt Lake valley, Utah, USA, and steam monitoring of The Geysers geothermal field, California, USA. Gravity measurements using modern relative high-precision meters, such as Scintrex CG-3Ms or L&R E series, can now be routinely made to an accuracy of 5 μ Gal. Such accuracy requires the use of time series analysis at each station, and non-linear instrument drift functions. Modern computerized meters are capable of internally storing a time series of measurements for each station; older meters can often be fitted to log such data to a field computer. This time series, typically of 10-15 minute duration in our work, can then be analyzed in several ways to produce stable estimates of the gravity reading. In particular, our research has emphasized using a weighted arithmetic average (for long occupations), or a Thiele extrapolation scheme (for shorter station occupations). Instrument drift is removed through a superposition of a linear long-term drift function, and an empirical staircase function formed from differences between repeated station occupations. To achieve high-accuracy GPS measurements while maximizing the number of field stations in a survey, rapid-static measurements are necessary. We have tested the effect of occupation time and processing schemes on the absolute accuracy of the resulting GPS position. Using a post-processing differential method with a fixed (but not necessarily continuous) base station within 15 km, positioning error of <4 cm vertical is

  5. Measurement and repeatability of interrupter resistance in unsedated newborn infants.

    Science.gov (United States)

    Adams, A M; Olden, C; Wertheim, D; Ives, A; Bridge, P D; Lenton, J; Seddon, P

    2009-12-01

    Interrupter resistance (R(int)) is a useful measure of airway caliber in young children, but has not been well characterized in infants-in whom there are concerns about the accurate measurement of driving pressure. This study aimed to assess the feasibility and repeatability of measuring R(int) in unsedated newborn infants, and to explore alternative algorithms for calculating driving pressure. R(int) measurement was attempted in 28 healthy term newborn infants during natural sleep using the MicroRint device. Paired R(int) measurements were achieved in 24 infants, but after screening of waveforms only 15 infants had at least 5 technically acceptable waveforms on both measurements. R(int) values obtained were comparable with reported values for airflow resistance in newborns using other methods. However, the repeatability coefficient (CR) was much higher than reported values in preschool children using standard back-extrapolation algorithms, with CR 2.47 KPa L(-1) sec (unscreened) and 2.93 KPa L(-1) sec (screened). Other algorithms gave only marginally better repeatability, with all CR values over 50% of the mean R(int) value. Using current commercially available equipment, R(int) is too poorly repeatable to be a reliable measurement of airflow resistance in newborn infants. Lower deadspace equipment is needed, but anatomical and physiological factors in the infant are also important.

  6. Bayesian Concordance Correlation Coefficient with Application to Repeatedly Measured Data

    Directory of Open Access Journals (Sweden)

    Atanu BHATTACHARJEE

    2015-10-01

    Full Text Available Objective: In medical research, Lin's classical concordance correlation coefficient (CCC is frequently applied to evaluate the similarity of the measurements produced by different raters or methods on the same subjects. It is particularly useful for continuous data. The objective of this paper is to propose the Bayesian counterpart to compute CCC for continuous data. Material and Methods: A total of 33 patients of astrocytoma brain treated in the Department of Radiation Oncology at Malabar Cancer Centre is enrolled in this work. It is a continuous data of tumor volume and tumor size repeatedly measured during baseline pretreatment workup and post surgery follow-ups for all patients. The tumor volume and tumor size are measured separately by MRI and CT scan. The agreement of measurement between MRI and CT scan is calculated through CCC. The statistical inference is performed through Markov Chain Monte Carlo (MCMC technique. Results: Bayesian CCC is found suitable to get prominent evidence for test statistics to explore the relation between concordance measurements. The posterior mean estimates and 95% credible interval of CCC on tumor size and tumor volume are observed with 0.96(0.87,0.99 and 0.98(0.95,0.99 respectively. Conclusion: The Bayesian inference is adopted for development of the computational algorithm. The approach illustrated in this work provides the researchers an opportunity to find out the most appropriate model for specific data and apply CCC to fulfill the desired hypothesis.

  7. Repeated swim stress alters brain benzodiazepine receptors measured in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Weizman, R.; Weizman, A.; Kook, K.A.; Vocci, F.; Deutsch, S.I.; Paul, S.M.

    1989-06-01

    The effects of repeated swim stress on brain benzodiazepine receptors were examined in the mouse using both an in vivo and in vitro binding method. Specific in vivo binding of (/sup 3/H)Ro15-1788 to benzodiazepine receptors was decreased in the hippocampus, cerebral cortex, hypothalamus, midbrain and striatum after repeated swim stress (7 consecutive days of daily swim stress) when compared to nonstressed mice. In vivo benzodiazepine receptor binding was unaltered after repeated swim stress in the cerebellum and pons medulla. The stress-induced reduction in in vivo benzodiazepine receptor binding did not appear to be due to altered cerebral blood flow or to an alteration in benzodiazepine metabolism or biodistribution because there was no difference in (14C)iodoantipyrine distribution or whole brain concentrations of clonazepam after repeated swim stress. Saturation binding experiments revealed a change in both apparent maximal binding capacity and affinity after repeated swim stress. Moreover, a reduction in clonazepam's anticonvulsant potency was also observed after repeated swim stress (an increase in the ED50 dose for protection against pentylenetetrazol-induced seizures), although there was no difference in pentylenetetrazol-induced seizure threshold between the two groups. In contrast to the results obtained in vivo, no change in benzodiazepine receptor binding kinetics was observed using the in vitro binding method. These data suggest that environmental stress can alter the binding parameters of the benzodiazepine receptor and that the in vivo and in vitro binding methods can yield substantially different results.

  8. Modeling repeated measurement data for occupational exposure assessment and epidemiology

    NARCIS (Netherlands)

    Peretz, Chava

    2004-01-01

    Repeated measurements designs, occur frequently in the assessment of exposure to toxic chemicals. This thesis deals with the possibilities of using mixed effects models for occupational exposure assessment and in the analysis of exposure response relationships. The model enables simultaneous estima

  9. Applying the General Linear Model to Repeated Measures Problems.

    Science.gov (United States)

    Pohlmann, John T.; McShane, Michael G.

    The purpose of this paper is to demonstrate the use of the general linear model (GLM) in problems with repeated measures on a dependent variable. Such problems include pretest-posttest designs, multitrial designs, and groups by trials designs. For each of these designs, a GLM analysis is demonstrated wherein full models are formed and restrictions…

  10. Repeatability of OCT lens thickness measures with age and accommodation.

    Science.gov (United States)

    Doyle, Lesley; Little, Julie-Anne; Saunders, Kathryn J

    2013-12-01

    To investigate crystalline lens thickness (LT) across a range of ages and accommodative demands and to evaluate the repeatability of LT measurements using the Visante Anterior Segment Optical Coherence Tomographer (AS-OCT) (Zeiss Meditec, Germany) under non-cycloplegic conditions. Participants were 98 visually normal adults aged 18-75 years, stratified into age groups of 18-29, 30-39, 40-49, 50-59, and 60-75 years of age. Images of the crystalline lens were taken using the Visante AS-OCT during stimulation of accommodation at demands of 0, 1, 2, 3, 4, 5, and 8 D with accommodative response measured in a subgroup of participants. Images were analyzed and LT measured assuming a refractive index of 1.42. Repeat measures were taken from 86 participants for each accommodative demand at a second visit. The mean unaccommodated LT for all participants was 4.07 ± 0.40 mm. An average increase in LT of 20 μm per year was calculated (linear regression, R² = 0.61, F(1,89) = 143.92, p report the repeatability of LT measures using the Visante AS-OCT in the non-cyclopleged eye. It has also demonstrated the ability of the Visante AS-OCT to detect small changes in lens thickness with accommodation.

  11. Measuring Repeatability of the Focus-variable Lenses

    Directory of Open Access Journals (Sweden)

    Jan Řezníček

    2014-12-01

    Full Text Available In the field of photogrammetry, the optical system, usually represented by the glass lens, is used for metric purposes. Therefore, the aberration characteristics of such a lens, inducing deviations from projective imaging, has to be well known. However, the most important property of the metric lens is the stability of its glass and mechanical elements, ensuring long-term reliability of the measured parameters. In case of a focus-variable lens, the repeatability of the lens setup is important as well. Lenses with a fixed focal length are usually considered as “fixed” though, in fact, most of them contain one or more movable glass elements, providing the focusing function. In cases where the lens is not equipped with fixing screws, the repeatability of the calibration parameters should be known. This paper derives simple mathematical formulas that can be used for measuring the repeatability of the focus-variable lenses, and gives a demonstrative example of such measuring. The given procedure has the advantage that only demanded parameters are estimated, hence, no unwanted correlations with the additional parameters exist. The test arrangement enables us to measure each demanded magnification of the optical system, which is important in close-range photogrammetry.

  12. Analysis of repeated measurements from medical research when observations are missing

    OpenAIRE

    Walker, K.

    2007-01-01

    Subject dropout is a common problem in repeated measurements health stud ies. Where dropout is related to the response, the results obtained can be substantially biased. The research in this thesis is motivated by a repeated measurements asthma clinical trial with substantial patient dropout. In practice the extent to which missing observations affect parameter esti mates and their efficiency is not clear. Through extensive simulation studies under various scenarios and missing data mechanism...

  13. Repeatability of gait pattern variables measured by use of extremity-mounted inertial measurement units in nonlame horses during trotting.

    Science.gov (United States)

    Cruz, Antonio M; Maninchedda, Ugo E; Burger, Dominik; Wanda, Sabine; Vidondo, Beatriz

    2017-09-01

    OBJECTIVE To determine repeatability of gait variables measured by use of extremity-mounted inertial measurement units (IMUs) in nonlame horses during trotting under controlled conditions of treadmill exercise. ANIMALS 10 horses. PROCEDURES Six IMUs were strapped to the metacarpal, metatarsal, and distal tibial regions of each horse. Data were collected in a standardized manner (3 measurements/d on 3 d/wk over a 3-week period) while each horse was trotted on a treadmill. Every measurement consisted of a minimum of 20 strides from which a minimum of 10 strides was selected for analysis. Spatial and temporal variables were derived from the IMUs. Repeatability coefficients based on the within-subject SD were computed for each gait analysis variable at each week. RESULTS Most of the temporal and spatial variables had high repeatability (repeatability coefficients variables, specifically the symmetry variables (which were calculated from other variables), had somewhat higher repeatability coefficients (ie, lower repeatability) only in the last week. CONCLUSIONS AND CLINICAL RELEVANCE With the exceptions of some symmetry variables, which may reflect individual variations during movement, the extremity-mounted IMUs provided data with high repeatability for nonlame horses trotting under controlled conditions of treadmill exercise. Repeatability was achieved for each instrumented limb segment with regard to the spatial relationship between 2 adjacent segments (joint angles) and the temporal relationship among all segments (limb phasing). Extremity-mounted IMUs could have the potential to become a method for gait analysis in horses.

  14. Assessment of bone loss with repeated bone mineral measurements: Application to measurements on the individual patient

    Energy Technology Data Exchange (ETDEWEB)

    Wahner, H.W.

    1987-02-01

    Longitudinal measurements on lumbar spine and mid-radius were made by bone absorptiometry techniques in 139 normal women. Bone mineral was measured every 6 months over an median interval of 2.1 years. The results revealed that bone loss at different skeletal sites is non-uniform with equal bone loss patterns in all patients and relatively small variations in bone loss rate between normal women. For achieving these results there is strong demand on high precision and properly spaced measuring intervals for long-term rate of loss measurements. For exclusion of progressive degenerative disease a radiographic evaluation of the spine in the beginning and at the end of the study is mandatory as compression fractures or trauma reveal bone mineral changes independent from the agerelated bone loss. These repeated bone mineral measurements are useful for monitoring and follow-up studies during different therapeutic regimens.

  15. Repeat aortocoronary bypass grafting. Early and late results.

    Science.gov (United States)

    Kobayashi, T; Mendez, A M; Zubiate, P; Vanstrom, N R; Yokoyama, T; Kay, J H

    1978-04-01

    Seventy-nine patients underwent repeat myocardial revascularization between March 1971 and January 1977. The initial procedure was performed at the St. Vincent Medical Center, Los Angeles, in 70 (2.0 percent) of 3,526 patients undergoing surgery for coronary arterial disease and in nine more patients was performed at other hospitals; the second operation followed the first procedure at an interval of from three weeks to 78 months. Five deaths (6 percent) occurred while patients were hospitalized, and six deaths (8 percent) occurred later. Two of the six later deaths were from noncardiac causes. Complications were not different from those that occurred during primary procedures. Thirty-six (60 percent) of 60 patients undergoing repeat surgery since 1973 did not receive any transfusions of blood during or after surgery. Of 48 patients followed-up for periods ranging from 12 to 70 months after the second operation, angina was completely relieved in 18 patients (38 percent), improved in 16 patients (33 percent), unchanged in 11 patients (23 percent), and worse in three patients (6 percent).

  16. Repeatability of Ocular Measurements with a Dual-Scheimpflug Analyzer in Healthy Eyes

    Directory of Open Access Journals (Sweden)

    Carmen Lopez de la Fuente

    2014-01-01

    Full Text Available Purpose. To assess the repeatability of the Galilei dual Scheimpflug analyzer (GDSA in anterior segment examination. Methods. Fifty-two eyes from 52 healthy volunteers were prospectively and consecutively recruited. Anatomic, axial, refractive, and instantaneous parameters were measured with GDSA to provide a complete characterization of the anterior segment. Repeatability was assessed calculating intraclass correlation coefficient (ICC, and coefficient of variation (COV. Results. Correlation among repeated measurements showed almost perfect reliability (ICC > 0.81 for all parameters except thinnest central corneal thickness (CCT (0.78, corneal thickness average out (0.79, and posterior axial curvature average out (0.60. Repeatability was excellent (COV < 10% for all parameters except anterior chamber volume and, superior iridocorneal angle and eccentricities. In these last three parameters, repeatability limits were excessively high compared to the mean. Conclusions. GDSA in healthy young persons had an almost perfect correlation in measuring anatomic, axial, instantaneous, and refractive parameters with greater variability for peripheral terms. Repeatability of anatomical parameters like pachymetry, anterior chamber, or iridocorneal angle and eccentricity were limited. In healthy young persons, the other evaluated parameters had very good repeatability and their limits of agreement showed excellent clinical results for this device.

  17. Modeling intraindividual variability with repeated measures data methods and applications

    CERN Document Server

    Hershberger, Scott L

    2013-01-01

    This book examines how individuals behave across time and to what degree that behavior changes, fluctuates, or remains stable.It features the most current methods on modeling repeated measures data as reported by a distinguished group of experts in the field. The goal is to make the latest techniques used to assess intraindividual variability accessible to a wide range of researchers. Each chapter is written in a ""user-friendly"" style such that even the ""novice"" data analyst can easily apply the techniques.Each chapter features:a minimum discussion of mathematical detail;an empirical examp

  18. Thyroid nodules with nondiagnostic results on repeat fine-needle aspiration biopsy: which nodules should be considered for repeat biopsy or surgery rather than follow-up?

    Science.gov (United States)

    2016-01-01

    Purpose: The goal of this study was to assess the clinicopathologic and ultrasonographic features of thyroid nodules with nondiagnostic results on repeat ultrasonography (US)-guided fineneedle aspiration biopsy (FNAB) according to size and the number of suspicious findings and to determine the proper management of nodules with consecutive nondiagnostic results. Methods: This retrospective study included 297 nodules with nondiagnostic results on repeat FNAB that were evaluated by US over the course of at least 12 months of follow-up, a follow-up biopsy, or an operation. We compared clinical and US variables between benign and malignant nodules in thyroid nodules with repeat nondiagnostic results. Results: The comparison of benign and malignant nodules with repeat nondiagnostic results revealed that age, marked hypoechogenicity, irregular or microlobulated margins, microcalcifications, and nonparallel shape were significantly associated with malignancy. Multivariate logistic regression analysis in malignant nodules revealed that microcalcifications and irregular or microlobulated margins were independently associated with malignancy. Among them, only irregular or microlobulated margins were independently significant as a predictor of malignancy in repeatedly nondiagnostic nodules measuring >10 mm. Using receiver operating characteristic analysis, the best cutoff value for the “number of suspicious findings” between benign and malignant nodules was three in nodules of all sizes, three in nodules measuring ≤10 mm, and two in nodules measuring >10 mm. Conclusion: Irregular or microlobulated margins may be the most frequent US features in repeatedly nondiagnostic nodules >10 mm. The presence of “two or more suspicious findings” can be used as the cutoff for distinguishing benign and malignant nodules. PMID:27068131

  19. Thyroid nodules with nondiagnostic results on repeat fine-needle aspiration biopsy: which nodules should be considered for repeat biopsy or surgery rather than follow-up?

    Directory of Open Access Journals (Sweden)

    Na Lae Eun

    2016-07-01

    Full Text Available Purpose: The goal of this study was to assess the clinicopathologic and ultrasonographic features of thyroid nodules with nondiagnostic results on repeat ultrasonography (US-guided fineneedle aspiration biopsy (FNAB according to size and the number of suspicious findings and to determine the proper management of nodules with consecutive nondiagnostic results. Methods: This retrospective study included 297 nodules with nondiagnostic results on repeat FNAB that were evaluated by US over the course of at least 12 months of follow-up, a follow-up biopsy, or an operation. We compared clinical and US variables between benign and malignant nodules in thyroid nodules with repeat nondiagnostic results. Results: The comparison of benign and malignant nodules with repeat nondiagnostic results revealed that age, marked hypoechogenicity, irregular or microlobulated margins, microcalcifications, and nonparallel shape were significantly associated with malignancy. Multivariate logistic regression analysis in malignant nodules revealed that microcalcifications and irregular or microlobulated margins were independently associated with malignancy. Among them, only irregular or microlobulated margins were independently significant as a predictor of malignancy in repeatedly nondiagnostic nodules measuring >10 mm. Using receiver operating characteristic analysis, the best cutoff value for the “number of suspicious findings” between benign and malignant nodules was three in nodules of all sizes, three in nodules measuring ≤10 mm, and two in nodules measuring >10 mm. Conclusion: Irregular or microlobulated margins may be the most frequent US features in repeatedly nondiagnostic nodules >10 mm. The presence of “two or more suspicious findings” can be used as the cutoff for distinguishing benign and malignant nodules.

  20. Quasar Variability Measurements With SDSS Repeated Imaging and POSS Data

    CERN Document Server

    Ivezic, Z; Juric, M; Anderson, S; Hall, P B; Richards, G T; Rockosi, C M; Vanden Berk, Daniel E; Turner, E L; Knapp, G R; Gunn, J E; Schlegel, D J; Strauss, M A; Schneider, D P

    2004-01-01

    We analyze the properties of quasar variability using repeated SDSS imaging data in five UV-to-far red photometric bands, accurate to 0.02 mag, for 13,000 spectroscopically confirmed quasars. The observed time lags span the range from 3 hours to over 3 years, and constrain the quasar variability for rest-frame time lags of up to two years, and at rest-frame wavelengths from 1000 Ang. to 6000 Ang. We demonstrate that 66,000 SDSS measurements of magnitude differences can be described within the measurement noise by a simple function of only three free parameters. The addition of POSS data constrains the long-term behavior of quasar variability and provides evidence for a turn-over in the structure function. This turn-over indicates that the characteristic time scale for optical variability of quasars is of the order 1 year.

  1. The concordance correlation coefficient for repeated measures estimated by variance components.

    Science.gov (United States)

    Carrasco, Josep L; King, Tonya S; Chinchilli, Vernon M

    2009-01-01

    The concordance correlation coefficient (CCC) is an index that is commonly used to assess the degree of agreement between observers on measuring a continuous characteristic. Here, a CCC for longitudinal repeated measurements is developed through the appropriate specification of the intraclass correlation coefficient from a variance components linear mixed model. A case example and the results of a simulation study are provided.

  2. Thyroid nodules with nondiagnostic results on repeat fine-needle aspiration biopsy: which nodules should be considered for repeat biopsy or surgery rather than follow-up?

    Energy Technology Data Exchange (ETDEWEB)

    Eun, Na Lae; Chang, Hang Seok; Gweon, Hye Mi; Kim, Jeong Ah; Youk, Ji Hyun; Son, Eun Jun [Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Yoo, Mi Ri [Dept. of Radiology, Dongjak Kyunghee Hospital, Seoul (Korea, Republic of); Park, Ah Young [Dept. of Radiology, Korea University Ansan Hospital, Korea University College of Medicine, Ansan (Korea, Republic of); Moon, Hee Jung [Dept. of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2016-07-15

    The goal of this study was to assess the clinicopathologic and ultrasonographic features of thyroid nodules with nondiagnostic results on repeat ultrasonography (US)-guided fineneedle aspiration biopsy (FNAB) according to size and the number of suspicious findings and to determine the proper management of nodules with consecutive nondiagnostic results. This retrospective study included 297 nodules with nondiagnostic results on repeat FNAB that were evaluated by US over the course of at least 12 months of follow-up, a follow-up biopsy, or an operation. We compared clinical and US variables between benign and malignant nodules in thyroid nodules with repeat nondiagnostic results. The comparison of benign and malignant nodules with repeat nondiagnostic results revealed that age, marked hypoechogenicity, irregular or microlobulated margins, microcalcifications, and nonparallel shape were significantly associated with malignancy. Multivariate logistic regression analysis in malignant nodules revealed that microcalcifications and irregular or microlobulated margins were independently associated with malignancy. Among them, only irregular or microlobulated margins were independently significant as a predictor of malignancy in repeatedly nondiagnostic nodules measuring >10 mm. Using receiver operating characteristic analysis, the best cutoff value for the “number of suspicious findings” between benign and malignant nodules was three in nodules of all sizes, three in nodules measuring ≤10 mm, and two in nodules measuring >10 mm. Irregular or microlobulated margins may be the most frequent US features in repeatedly nondiagnostic nodules >10 mm. The presence of “two or more suspicious findings” can be used as the cutoff for distinguishing benign and malignant nodules.

  3. Dispersion Measure Variation of Repeating Fast Radio Burst Sources

    Science.gov (United States)

    Yang, Yuan-Pei; Zhang, Bing

    2017-09-01

    The repeating fast radio burst (FRB) 121102 was recently localized in a dwarf galaxy at a cosmological distance. The dispersion measure (DM) derived for each burst from FRB 121102 so far has not shown significant evolution, even though an apparent increase was recently seen with newly detected VLA bursts. It is expected that more repeating FRB sources may be detected in the future. In this work, we investigate a list of possible astrophysical processes that might cause DM variation of a particular FRB source. The processes include (1) cosmological scale effects such as Hubble expansion and large-scale structure fluctuations; (2) FRB local effects such as gas density fluctuation, expansion of a supernova remnant (SNR), a pulsar wind nebula, and an H ii region; and (3) the propagation effect due to plasma lensing. We find that the DM variations contributed by the large-scale structure are extremely small, and any observable DM variation is likely caused by the plasma local to the FRB source. In addition to mechanisms that decrease DM over time, we suggest that an FRB source in an expanding SNR around a nearly neutral ambient medium during the deceleration (Sedov–Taylor and snowplow) phases or in a growing H ii region can increase DM. Some effects (e.g., an FRB source moving in an H ii region or plasma lensing) can produce either positive or negative DM variations. Future observations of DM variations of FRB 121102 and other repeating FRB sources can provide important clues regarding the physical origin of these sources.

  4. Detecting tropical forest biomass dynamics from repeated airborne lidar measurements

    Directory of Open Access Journals (Sweden)

    V. Meyer

    2013-08-01

    census data, differences of approximately one year between the ground census and lidar measurements, and differences in sensor characteristics. Our results indicate that the 50 ha BCI plot lost a significant amount of biomass (−0.8 Mg ha−1 yr−1 ± 2.2(SD over the past decade (2000–2010. Over the entire island and during the same period, mean AGB change was 0.2 ± 2.4 Mg ha−1 yr−1 with old growth forests losing −0.7 Mg ha−1 yr−1 ± 2.2 (SD, and secondary forests gaining +1.8 Mg ha yr−1 ± 3.4 (SD biomass. Our analysis suggests that repeated lidar surveys, despite taking measurement with different sensors, can estimate biomass changes in old-growth tropical forests at landscape scales (>10 ha.

  5. A Simple and Transparent Alternative to Repeated Measures ANOVA

    Directory of Open Access Journals (Sweden)

    James W. Grice

    2015-09-01

    Full Text Available Observation Oriented Modeling is a novel approach toward conceptualizing and analyzing data. Compared with traditional parametric statistics, Observation Oriented Modeling is more intuitive, relatively free of assumptions, and encourages researchers to stay close to their data. Rather than estimating abstract population parameters, the overarching goal of the analysis is to identify and explain distinct patterns within the observations. Selected data from a recent study by Craig et al. were analyzed using Observation Oriented Modeling; this analysis was contrasted with a traditional repeated measures ANOVA assessment. Various pitfalls in traditional parametric analyses were avoided when using Observation Oriented Modeling, including the presence of outliers and missing data. The differences between Observation Oriented Modeling and various parametric and nonparametric statistical methods were finally discussed.

  6. The Impact of Repeated Lying on Survey Results

    Directory of Open Access Journals (Sweden)

    Thomas Chesney

    2013-01-01

    Full Text Available We study the effects on results of participants completing a survey more than once, a phenomenon known as farming. Using data from a real social science study as a baseline, three strategies that participants might use to farm are studied by Monte Carlo simulation. Findings show that farming influences survey results and can cause both statistical hypotheses testing Type I (false positive and Type II (false negative errors in unpredictable ways.

  7. Matrix-based concordance correlation coefficient for repeated measures.

    Science.gov (United States)

    Hiriote, Sasiprapa; Chinchilli, Vernon M

    2011-09-01

    In many clinical studies, Lin's concordance correlation coefficient (CCC) is a common tool to assess the agreement of a continuous response measured by two raters or methods. However, the need for measures of agreement may arise for more complex situations, such as when the responses are measured on more than one occasion by each rater or method. In this work, we propose a new CCC in the presence of repeated measurements, called the matrix-based concordance correlation coefficient (MCCC) based on a matrix norm that possesses the properties needed to characterize the level of agreement between two p× 1 vectors of random variables. It can be shown that the MCCC reduces to Lin's CCC when p= 1. For inference, we propose an estimator for the MCCC based on U-statistics. Furthermore, we derive the asymptotic distribution of the estimator of the MCCC, which is proven to be normal. The simulation studies confirm that overall in terms of accuracy, precision, and coverage probability, the estimator of the MCCC works very well in general cases especially when n is greater than 40. Finally, we use real data from an Asthma Clinical Research Network (ACRN) study and the Penn State Young Women's Health Study for demonstration.

  8. A Novel Signal Processing Measure to Identify Exact and Inexact Tandem Repeat Patterns in DNA Sequences

    Directory of Open Access Journals (Sweden)

    Ravi Gupta

    2007-03-01

    Full Text Available The identification and analysis of repetitive patterns are active areas of biological and computational research. Tandem repeats in telomeres play a role in cancer and hypervariable trinucleotide tandem repeats are linked to over a dozen major neurodegenerative genetic disorders. In this paper, we present an algorithm to identify the exact and inexact repeat patterns in DNA sequences based on orthogonal exactly periodic subspace decomposition technique. Using the new measure our algorithm resolves the problems like whether the repeat pattern is of period P or its multiple (i.e., 2P, 3P, etc., and several other problems that were present in previous signal-processing-based algorithms. We present an efficient algorithm of O(NLw logLw, where N is the length of DNA sequence and Lw is the window length, for identifying repeats. The algorithm operates in two stages. In the first stage, each nucleotide is analyzed separately for periodicity, and in the second stage, the periodic information of each nucleotide is combined together to identify the tandem repeats. Datasets having exact and inexact repeats were taken up for the experimental purpose. The experimental result shows the effectiveness of the approach.

  9. Accuracy and repeatability of a new method for measuring facet loads in the lumbar spine.

    Science.gov (United States)

    Wilson, Derek C; Niosi, Christina A; Zhu, Qingan A; Oxland, Thomas R; Wilson, David R

    2006-01-01

    We assessed the repeatability and accuracy of a relatively new, resistance-based sensor (Tekscan 6900) for measuring lumbar spine facet loads, pressures, and contact areas in cadaver specimens. Repeatability of measurements in the natural facet joint was determined for five trials of four specimens loaded in pure moment (+/- 7.5 N m) flexibility tests in axial rotation and flexion-extension. Accuracy of load measurements in four joints was assessed by applying known compressive loads of 25, 50, and 100 N to the natural facet joint in a materials testing machine and comparing the known applied load to the measured load. Measurements of load were obtained using two different calibration approaches: linear and two-point calibrations. Repeatability for force, pressure, and area (average of standard deviation as a percentage of the mean for all trials over all specimens) was 4-6% for axial rotation and 7-10% for extension. Peak resultant force in axial rotation was 30% smaller when calculated using the linear calibration method. The Tekscan sensor overestimated the applied force by 18 +/- 9% (mean+/-standard deviation), 35 +/- 7% and 50 +/- 9% for compressive loads of 100, 50, and 25 N, respectively. The two-point method overestimated the loads by 35 +/- 16%, 45 +/- 7%, and 56 +/- 10% for the same three loads. Our results show that the Tekscan sensor is repeatable. However, the sensor measurement range is not optimal for the small loads transmitted by the facets and measurement accuracy is highly dependent on calibration protocol.

  10. Repeated quantitative perfusion and contrast permeability measurement in the MRI examination of a CNS tumor

    Energy Technology Data Exchange (ETDEWEB)

    Vonken, E.P.A.; Osch, M.J.P. van; Willems, P.W.A.; Zwan, A. van der; Bakker, C.J.G.; Viergever, M.A.; Mali, W.P.T.M. [University Hospital Utrecht (Netherlands)

    2000-09-01

    This study reports on the results of quantitative MRI perfusion and contrast permeability measurement on two occasions in one patient. The measurements were separated 81 days in time. The tumor grew considerably in this period, but no change was found with respect to perfusion and contrast permeability. Non-involved white matter values were reproduced to demonstrate repeatability. The presented approach to dynamic susceptibility contrast MRI allows fast and repeatable quantitative assessment of perfusion and is easily integrated in a conventional brain tumor protocol. (orig.)

  11. The effect of repeated measurements and working memory on the most comfortable level in the ANL test

    DEFF Research Database (Denmark)

    Brännström, K Jonas; Olsen, Steen Østergaard; Holm, Lucas

    2014-01-01

    interleaved methodology during one session using a non-semantic version. Phonological (PWM) and visuospatial working memory (VSWM) was measured. STUDY SAMPLE: Thirty-two normal-hearing adults. RESULTS: Repeated measures ANOVA, intraclass correlations, and the coefficient of repeatability (CR) were used...

  12. [Analysis of binary classification repeated measurement data with GEE and GLMMs using SPSS software].

    Science.gov (United States)

    An, Shengli; Zhang, Yanhong; Chen, Zheng

    2012-12-01

    To analyze binary classification repeated measurement data with generalized estimating equations (GEE) and generalized linear mixed models (GLMMs) using SPSS19.0. GEE and GLMMs models were tested using binary classification repeated measurement data sample using SPSS19.0. Compared with SAS, SPSS19.0 allowed convenient analysis of categorical repeated measurement data using GEE and GLMMs.

  13. Graphic Methods for Interpreting Longitudinal Dyadic Patterns From Repeated-Measures Actor-Partner Interdependence Models

    DEFF Research Database (Denmark)

    Perry, Nicholas; Baucom, Katherine; Bourne, Stacia

    2017-01-01

    Researchers commonly use repeated-measures actor–partner interdependence models (RM-APIM) to understand how romantic partners change in relation to one another over time. However, traditional interpretations of the results of these models do not fully or correctly capture the dyadic temporal...

  14. Intraexaminer repeatability and agreement in stereoacuity measurements made in young adults

    Directory of Open Access Journals (Sweden)

    Beatriz Antona

    2015-04-01

    Full Text Available AIM: To determine the repeatability and agreement of stereoacuity measurements made using some of the most widely used clinical tests: Frisby, TNO, Randot and Titmus. METHODS: Stereoacuity was measured in two different sessions separated by a time interval of at least 24h but no longer than 1wk in 74 subjects of mean age 20.6y using the four methods. The study participants were divided into two groups: subjects with normal binocular vision and subjects with abnormal binocular vision. RESULTS: Best repeatability was shown by the Frisby and Titmus [coefficient of repeatability (COR: ±13 and ±12s arc respectively] in the subjects with normal binocular vision though a clear ceiling effect was noted. In the subjects with abnormal binocular vision, best repeatability was shown by the Frisby (COR: ±69s arc and Randot (COR: ±72s arc. In both groups, the TNO test showed poorest agreement with the other tests. CONCLUSION: The repeatability of stereoacuity measures was low in subjects with poor binocular vision yet fairly good in subjects with normal binocular vision with the exception of the TNO test. The reduced agreement detected between the tests indicates they cannot be used interchangeably.

  15. Repeatability of the modified Thorington card used to measure far heterophoria.

    Science.gov (United States)

    Cebrian, Jose Luis; Antona, Beatriz; Barrio, Ana; Gonzalez, Enrique; Gutierrez, Angel; Sanchez, Isabel

    2014-07-01

    To determine the interexaminer and intraexaminer repeatability of the modified Thorington test (TH) for distance vision in young adults and to compare these results with those observed for the heterophoria tests most commonly used in clinical practice. Agreement among tests was also assessed. Distance heterophoria was quantified on two separate occasions by two examiners in 110 subjects aged 18 to 32 years (mean, 19.74 years; SD, 2.5 years) using four different tests: cover test (CT) Von Graefe, Maddox rod, and modified TH. The repeatability of the tests and agreement between them was estimated by the Bland and Altman method whereby the mean difference and the 95% limits of agreement were determined as the coefficient of repeatability (COR) and coefficient of agreement. The Thorington test showed best interexaminer repeatability (COR = ±1.43Δ), followed closely by CT (COR = ±1.65Δ), whereas best intraexaminer repeatability was observed for CT (COR = ±1.28Δ) followed by TH (COR = ±1.51Δ). Among the different combinations of tests, TH and CT showed best agreement indicated by the lowest coefficient of agreement (±2.23Δ) and a low mean difference (-0.63Δ) between measurements. Good interexaminer and intraexaminer repeatability was observed for both TH and CT, and agreement between the two tests was also good. Given the simple administration of the TH, we recommend its clinical use to quantify distance horizontal heterophoria.

  16. Rank-Based Analysis of Unbalanced Repeated Measures Data

    Directory of Open Access Journals (Sweden)

    M. Mushfiqur Rashid

    2012-07-01

    Full Text Available Normal 0 false false false EN-US X-NONE X-NONE /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman","serif";} In this article, we have developed a rank (intra-subject based analysis of clinical trials with unbalanced repeated measures data. We assume that the errors within each patient are exchangeable and continuous random variables. This rank-based inference is valid when the unbalanced data are missing either completely at random or by design. A drop in dispersion test is developed for general linear hypotheses. A numerical example is given to illustrate the procedure.

  17. Results of the 2015 Spitzer Exoplanet Data Challenge: Repeatability and Accuracy of Exoplanet Eclipse Depths

    Science.gov (United States)

    Ingalls, James G.; Krick, Jessica E.; Carey, Sean J.; Stauffer, John R.; Grillmair, Carl J.; Lowrance, Patrick

    2016-06-01

    We examine the repeatability, reliability, and accuracy of differential exoplanet eclipse depth measurements made using the InfraRed Array Camera (IRAC) on the Spitzer Space Telescope during the post-cryogenic mission. At infrared wavelengths secondary eclipses and phase curves are powerful tools for studying a planet’s atmosphere. Extracting information about atmospheres, however, is extremely challenging due to the small differential signals, which are often at the level of 100 parts per million (ppm) or smaller, and require the removal of significant instrumental systematics. For the IRAC 3.6 and 4.5μm InSb detectors that remain active on post-cryogenic Spitzer, the interplay of residual telescope pointing fluctuations with intrapixel gain variations in the moderately under sampled camera is the largest source of time-correlated noise. Over the past decade, a suite of techniques for removing this noise from IRAC data has been developed independently by various investigators. In summer 2015, the Spitzer Science Center hosted a Data Challenge in which seven exoplanet expert teams, each using a different noise-removal method, were invited to analyze 10 eclipse measurements of the hot Jupiter XO-3 b, as well as a complementary set of 10 simulated measurements. In this contribution we review the results of the Challenge. We describe statistical tools to assess the repeatability, reliability, and validity of data reduction techniques, and to compare and (perhaps) choose between techniques.

  18. Concordance correlation coefficients estimated by generalized estimating equations and variance components for longitudinal repeated measurements.

    Science.gov (United States)

    Tsai, Miao-Yu

    2017-04-15

    The concordance correlation coefficient (CCC) is a commonly accepted measure of agreement between two observers for continuous responses. This paper proposes a generalized estimating equations (GEE) approach allowing dependency between repeated measurements over time to assess intra-agreement for each observer and inter- and total agreement among multiple observers simultaneously. Furthermore, the indices of intra-, inter-, and total agreement through variance components (VC) from an extended three-way linear mixed model (LMM) are also developed with consideration of the correlation structure of longitudinal repeated measurements. Simulation studies are conducted to compare the performance of the GEE and VC approaches for repeated measurements from longitudinal data. An application of optometric conformity study is used for illustration. In conclusion, the GEE approach allowing flexibility in model assumptions and correlation structures of repeated measurements gives satisfactory results with small mean square errors and nominal 95% coverage rates for large data sets, and when the assumption of the relationship between variances and covariances for the extended three-way LMM holds, the VC approach performs outstandingly well for all sample sizes. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  19. Repeatability of central corneal thickness measurement with the Pentacam HR system

    Directory of Open Access Journals (Sweden)

    Ruiz Simonato Alonso

    2012-02-01

    Full Text Available PURPOSE: To assess the repeatability of central corneal thickness measurement at the geometrical center (Central Corneal Thickness - CCT given by the Pentacam High Resolution (HR Comprehensive Eye Scanner (Oculus, Wetzlar, Germany over time. METHODS: Prospective, single center, observational study. Two separate CCT measurements were taken by the Pentacam corneal tomography exam (CTm 3 to 12 months apart, and compared. RESULTS: One hundred and sixteen eyes (n=116 of 62 health patients were included in this study. Average CCT in first and last visits was 541.6±37 µm and 543.6±36.9 µm respectively. Mean difference between both measurements was 9.2±6.4 µm, and there was no statistically significant difference in CCT measurement between visits, with good correlation between them (P = 0.057, r² = 0,9209. CONCLUSION: Pentacam (HR CTm gives repeatable CCT measurements over time.

  20. Repeatability of cardiac-MRI-measured right ventricular size and function in congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Walsh, Rowan; Salem, Yishay [Mount Sinai School of Medicine, Division of Pediatric Cardiology, New York, NY (United States); Shah, Amee; Lai, Wyman W. [Morgan Stanley Children' s Hospital of New York Presbyterian, New York, NY (United States); Nielsen, James C. [Mount Sinai School of Medicine, Division of Pediatric Cardiology, New York, NY (United States); Mount Sinai Children' s Heart Center, Box 1201, New York, NY (United States)

    2011-08-15

    The measurement error for right ventricular (RV) size and function assessed by cardiac MRI (CMRI) in congenital heart disease has not been fully characterized. As CMRI parameters are being increasingly utilized to make clinical decisions, defining error in the clinical setting is critical. This investigation examines the repeatability of CMRI for RV size and function. Forty consecutive people with congenital heart disease involving the RV were retrospectively identified. Contouring of RV volumes was performed by two expert CMRI clinicians. The coefficient of variability and repeatability coefficients were calculated. Repeatability coefficients were multiplied by the mean value for each group studied to define a threshold beyond which measurement error was unlikely to be responsible. The variability for indexed RV end-diastolic volume = 3.2% and 3.3% for intra- and interobserver comparisons, respectively. The repeatability coefficients were 13.2% and 14.9% for intra- and interobserver comparisons, which yielded threshold values of 15.1 ml/m{sup 2} and 20.2 ml/m{sup 2}, respectively. For RV ejection fraction (EF), the repeatability coefficients for intra- and interobserver comparisons were 5.0% and 6.0%, which resulted in threshold values of 2.6 EF% and 3.0 EF%. The threshold values generated can be used during serial assessment of RV size and function. (orig.)

  1. Accuracy and repeatability of an optical motion analysis system for measuring small deformations of biological tissues.

    Science.gov (United States)

    Liu, Helen; Holt, Cathy; Evans, Sam

    2007-01-01

    Optical motion analysis techniques have been widely used in biomechanics for measuring large-scale motions such as gait, but have not yet been significantly explored for measuring smaller movements such as the tooth displacements under load. In principle, very accurate measurements could be possible and this could provide a valuable tool in many engineering applications. The aim of this study was to evaluate accuracy and repeatability of the Qualisys ProReflex-MCU120 system when measuring small displacements, as a step towards measuring tooth displacements to characterise the properties of the periodontal ligament. Accuracy and repeatability of the system was evaluated using a wedge comparator with a resolution of 0.25 microm to provide measured marker displacements in three orthogonal directions. The marker was moved in ten steps in each direction, for each of seven step sizes (0.5, 1, 2, 3, 5, 10, and 20 microm), repeated five times. Spherical and diamond markers were tested. The system accuracy (i.e. percentage of maximum absolute error in range/measurement range), in the 20-200 microm ranges, was +/-1.17%, +/-1.67% and +/-1.31% for the diamond marker in x, y and z directions, while the system accuracy for the spherical marker was +/-1.81%, +/-2.37% and +/-1.39%. The system repeatability (i.e. maximum standard deviation in the measurement range) measured under the different days, light intensity and temperatures for five times, carried out step up and then step down measurements for the same step size, was +/-1.7, +/-2.3 and +/-1.9 microm for the diamond marker, and +/-2.6, +/-3.9 and +/-1.9 microm for the spherical marker in x, y and z directions, respectively. These results demonstrate that the system suffices accuracy for measuring tooth displacements and could potentially be useful in many other applications.

  2. Antarctic Ice Sheet Slope and Aspect Based on Icesat's Repeat Orbit Measurement

    Science.gov (United States)

    Yuan, L.; Li, F.; Zhang, S.; Xie, S.; Xiao, F.; Zhu, T.; Zhang, Y.

    2017-09-01

    Accurate information of ice sheet surface slope is essential for estimating elevation change by satellite altimetry measurement. A study is carried out to recover surface slope of Antarctic ice sheet from Ice, Cloud and land Elevation Satellite (ICESat) elevation measurements based on repeat orbits. ICESat provides repeat ground tracks within 200 meters in cross-track direction and 170 meters in along-track direction for most areas of Antarctic ice sheet. Both cross-track and along-track surface slopes could be obtained by adjacent repeat ground tracks. Combining those measurements yields a surface slope model with resolution of approximately 200 meters. An algorithm considering elevation change is developed to estimate the surface slope of Antarctic ice sheet. Three Antarctic Digital Elevation Models (DEMs) were used to calculate surface slopes. The surface slopes from DEMs are compared with estimates by using in situ GPS data in Dome A, the summit of Antarctic ice sheet. Our results reveal an average surface slope difference of 0.02 degree in Dome A. High resolution remote sensing images are also used in comparing the results derived from other DEMs and this paper. The comparison implies that our results have a slightly better coherence with GPS observation than results from DEMs, but our results provide more details and perform higher accuracy in coastal areas because of the higher resolution for ICESat measurements. Ice divides are estimated based on the aspect, and are weakly consistent with ice divides from other method in coastal regions.

  3. [Analysis of variance of repeated data measured by water maze with SPSS].

    Science.gov (United States)

    Qiu, Hong; Jin, Guo-qin; Jin, Ru-feng; Zhao, Wei-kang

    2007-01-01

    To introduce the method of analyzing repeated data measured by water maze with SPSS 11.0, and offer a reference statistical method to clinical and basic medicine researchers who take the design of repeated measures. Using repeated measures and multivariate analysis of variance (ANOVA) process of the general linear model in SPSS and giving comparison among different groups and different measure time pairwise. Firstly, Mauchly's test of sphericity should be used to judge whether there were relations among the repeatedly measured data. If any (PSPSS statistical package is available to fulfil this process.

  4. Optimal selection of individuals for repeated covariate measurements in follow-up studies.

    Science.gov (United States)

    Reinikainen, Jaakko; Karvanen, Juha; Tolonen, Hanna

    2016-12-01

    Repeated covariate measurements bring important information on the time-varying risk factors in long epidemiological follow-up studies. However, due to budget limitations, it may be possible to carry out the repeated measurements only for a subset of the cohort. We study cost-efficient alternatives for the simple random sampling in the selection of the individuals to be remeasured. The proposed selection criteria are based on forms of the D-optimality. The selection methods are compared with the simulation studies and illustrated with the data from the East-West study carried out in Finland from 1959 to 1999. The results indicate that cost savings can be achieved if the selection is focused on the individuals with high expected risk of the event and, on the other hand, on those with extreme covariate values in the previous measurements. © The Author(s) 2014.

  5. Repeatability and reproducibility of horizontal corneal diameter and anterior corneal power measurements using the Oculus Keratograph 4

    Directory of Open Access Journals (Sweden)

    Khathutshelo P. Mashige

    2016-03-01

    Full Text Available Purpose: To evaluate the repeatability and reproducibility of horizontal corneal diameter (HCD and anterior corneal power (ACP measurements obtained with the Oculus Keratograph 4 (OCULUS Optikgeräte GmbH.Methods: These parameters (HCD and ACP were prospectively measured in quick succession three times in each of the right eyes of 40 healthy subjects, aged 18–28 years, with normal vision (6/6 or better visual acuity in the first session by a single examiner. Measurements were then repeated in the second session scheduled 1 week later by the same examiner using the same instrument. Repeatability and reproducibility of HCD and ACP measurements was assessed based on the intra-session and intersession within-subject standard deviation (sw, repeatability (2.77sw, coefficient of variation (CoV and intra-class correlation coefficient (ICC.Results: Intra-session repeatability and intersession reproducibility of all measured parameters showed a repeatability (2.77sw of 0.35 mm or less for HCD and 0.35 D or less for ACP, a CoV of 0.30% or less and an ICC of more than 0.9.Conclusion: HCD and ACP measurements obtained using an Oculus Keratograph 4 show good repeatability and reproducibility in healthy eyes; therefore, these parameters can be used for longitudinal follow-up when measured with this device.

  6. Intraexaminer repeatability and agreement in stereoacuity measurements made in young adults

    Institute of Scientific and Technical Information of China (English)

    Beatriz; Antona; Ana; Barrio; Isabel; Sanchez; Enrique; Gonzalez; Guadalupe; Gonzalez

    2015-01-01

    AIM: To determine the repeatability and agreement of stereoacuity measurements made using some of the most widely used clinical tests: Frisby, TNO, Randot and Titmus.METHODS: Stereoacuity was measured in two different sessions separated by a time interval of at least 24 h but no longer than 1wk in 74 subjects of mean age 20.6y using the four methods. The study participants were divided into two groups: subjects with normal binocular vision and subjects with abnormal binocular vision.RESULTS: Best repeatability was shown by the Frisby and Titmus [coefficient of repeatability(COR): ±13 and±12s arc respectively] in the subjects with normal binocular vision though a clear ceiling effect was noted.In the subjects with abnormal binocular vision, best repeatability was shown by the Frisby(COR: ±69s arc)and Randot(COR: ±72s arc). In both groups, the TNO test showed poorest agreement with the other tests.CONCLUSION:Therepeatabilityofstereoacuitymeasures was low in subjects with poor binocular vision yet fairly good in subjects with normal binocular vision with the exception of the TNO test. The reduced agreement detected between the tests indicates they cannot be used interchangeably.

  7. Repeatability, variability and reference values of pulsed wave Doppler echocardiographic measurements in healthy Saanen goats

    Directory of Open Access Journals (Sweden)

    Leroux Aurélia A

    2012-10-01

    Full Text Available Abstract Background Pulsed wave (PW Doppler echocardiography has become a routine non invasive cardiac diagnostic tool in most species. However, evaluation of intracardiac blood flow requires reference values, which are poorly documented in goats. The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy adult Saanen goats. Using a standardised PW Doppler echocardiographic protocol, 10 healthy adult unsedated female Saanen goats were investigated three times at one day intervals by the same observer. Mitral, tricuspid, aortic and pulmonary flows were measured from a right parasternal view, and mitral and aortic flows were also measured from a left parasternal view. The difference between left and right side measurements and the intra-observer inter-day repeatability were tested and then the reference values of PW Doppler echocardiographic parameters in healthy adult female Saanen goats were established. Results As documented in other species, all caprine PW Doppler parameters demonstrated a poor inter-day repeatability and a moderate variability. Tricuspid and pulmonary flows were best evaluated on the right side whereas mitral and aortic flows were best obtained on the left side, and reference values are reported for healthy adult Saanen goats. Conclusions PW Doppler echocardiography allows the measurement of intracardiac blood flow indices in goats. The reference values establishment will help interpreting these indices of cardiac function in clinical cardiac cases and developing animal models for human cardiology research.

  8. Predicting seed yield in perennial ryegrass using repeated canopy reflectance measurements and PLSR

    DEFF Research Database (Denmark)

    Gislum, René; Deleuran, Lise Christina; Boelt, Birte

    2009-01-01

    Repeated canopy reflectance measurements together with partial least-squares regression (PLSR) were used to predict seed yield in perennial ryegrass (Lolium perenne L.). The measurements were performed during the spring and summer growing seasons of 2001 to 2003 in three field experiments...... reflectance measurements was from approximately 600 cumulative growing degree-days (CGDD) to approximately 900 CGDD. This is the period just before and at heading of the seed crop. Furthermore, regression coefficients showed that information about N and water is important. The results support the development...

  9. Status of a UAV SAR Designed for Repeat Pass Interferometry for Deformation Measurements

    Science.gov (United States)

    Hensley, Scott; Wheeler, Kevin; Hoffman, Jim; Miller, Tim; Lou, Yunling; Muellerschoen, Ron; Zebker, Howard; Madsen, Soren; Rosen, Paul

    2004-01-01

    Under the NASA ESTO sponsored Instrument Incubator Program we have designed a lightweight, reconfigurable polarimetric L-band SAR designed for repeat pass deformation measurements of rapidly deforming surfaces of geophysical interest such as volcanoes or earthquakes. This radar will be installed on an unmanned airborne vehicle (UAV) or a lightweight, high-altitude, and long endurance platform such as the Proteus. After a study of suitable available platforms we selected the Proteus for initial development and testing of the system. We want to control the repeat track capability of the aircraft to be within a 10 m tube to support the repeat deformation capability. We conducted tests with the Proteus using real-time GPS with sub-meter accuracy to see if pilots could fly the aircraft within the desired tube. Our results show that pilots are unable to fly the aircraft with the desired accuracy and therefore an augmented autopilot will be required to meet these objectives. Based on the Proteus flying altitude of 13.7 km (45,000 ft), we are designing a fully polarimetric L-band radar with 80 MHz bandwidth and 16 km range swath. This radar will have an active electronic beam steering antenna to achieve Doppler centroid stability that is necessary for repeat-pass interferometry (RPI). This paper will present are design criteria, current design and expected science applications.

  10. Using repeated measures of sleep disturbances to predict future diagnosis-specific work disability

    DEFF Research Database (Denmark)

    Salo, Paula; Vahtera, Jussi; Hall, Martica

    2012-01-01

    It is unknown whether or not measuring sleep disturbances repeatedly, rather than at only one point in time, improves prediction of work disability.......It is unknown whether or not measuring sleep disturbances repeatedly, rather than at only one point in time, improves prediction of work disability....

  11. Intelligence Is in the Eye of the Beholder: Investigating Repeated IQ Measurements in Forensic Psychiatry

    Science.gov (United States)

    Habets, Petra; Jeandarme, Inge; Uzieblo, Kasia; Oei, Karel; Bogaerts, Stefan

    2015-01-01

    Background: A stable assessment of cognition is of paramount importance for forensic psychiatric patients (FPP). The purpose of this study was to compare repeated measures of IQ scores in FPPs with and without intellectual disability. Methods: Repeated measurements of IQ scores in FPPs (n = 176) were collected. Differences between tests were…

  12. Intelligence Is in the Eye of the Beholder: Investigating Repeated IQ Measurements in Forensic Psychiatry

    Science.gov (United States)

    Habets, Petra; Jeandarme, Inge; Uzieblo, Kasia; Oei, Karel; Bogaerts, Stefan

    2015-01-01

    Background: A stable assessment of cognition is of paramount importance for forensic psychiatric patients (FPP). The purpose of this study was to compare repeated measures of IQ scores in FPPs with and without intellectual disability. Methods: Repeated measurements of IQ scores in FPPs (n = 176) were collected. Differences between tests were…

  13. Analysis of oligonucleotide array experiments with repeated measures using mixed models

    Directory of Open Access Journals (Sweden)

    Getchell Thomas V

    2004-12-01

    Full Text Available Abstract Background Two or more factor mixed factorial experiments are becoming increasingly common in microarray data analysis. In this case study, the two factors are presence (Patients with Alzheimer's disease or absence (Control of the disease, and brain regions including olfactory bulb (OB or cerebellum (CER. In the design considered in this manuscript, OB and CER are repeated measurements from the same subject and, hence, are correlated. It is critical to identify sources of variability in the analysis of oligonucleotide array experiments with repeated measures and correlations among data points have to be considered. In addition, multiple testing problems are more complicated in experiments with multi-level treatments or treatment combinations. Results In this study we adopted a linear mixed model to analyze oligonucleotide array experiments with repeated measures. We first construct a generalized F test to select differentially expressed genes. The Benjamini and Hochberg (BH procedure of controlling false discovery rate (FDR at 5% was applied to the P values of the generalized F test. For those genes with significant generalized F test, we then categorize them based on whether the interaction terms were significant or not at the α-level (αnew = 0.0033 determined by the FDR procedure. Since simple effects may be examined for the genes with significant interaction effect, we adopt the protected Fisher's least significant difference test (LSD procedure at the level of αnew to control the family-wise error rate (FWER for each gene examined. Conclusions A linear mixed model is appropriate for analysis of oligonucleotide array experiments with repeated measures. We constructed a generalized F test to select differentially expressed genes, and then applied a specific sequence of tests to identify factorial effects. This sequence of tests applied was designed to control for gene based FWER.

  14. High-Dimensional Multivariate Repeated Measures Analysis with Unequal Covariance Matrices

    Science.gov (United States)

    Harrar, Solomon W.; Kong, Xiaoli

    2015-01-01

    In this paper, test statistics for repeated measures design are introduced when the dimension is large. By large dimension is meant the number of repeated measures and the total sample size grow together but either one could be larger than the other. Asymptotic distribution of the statistics are derived for the equal as well as unequal covariance cases in the balanced as well as unbalanced cases. The asymptotic framework considered requires proportional growth of the sample sizes and the dimension of the repeated measures in the unequal covariance case. In the equal covariance case, one can grow at much faster rate than the other. The derivations of the asymptotic distributions mimic that of Central Limit Theorem with some important peculiarities addressed with sufficient rigor. Consistent and unbiased estimators of the asymptotic variances, which make efficient use of all the observations, are also derived. Simulation study provides favorable evidence for the accuracy of the asymptotic approximation under the null hypothesis. Power simulations have shown that the new methods have comparable power with a popular method known to work well in low-dimensional situation but the new methods have shown enormous advantage when the dimension is large. Data from Electroencephalograph (EEG) experiment is analyzed to illustrate the application of the results. PMID:26778861

  15. Repeatability and Comparison of Keratometry Values Measured with Potec PRK-6000 Autorefractometer, IOLMaster, and Pentacam

    Directory of Open Access Journals (Sweden)

    Adem Türk

    2014-05-01

    Full Text Available Objectives: To research the repeatability and intercompatibility of keratometry values measured with Potec PRK-6000 autorefractometer, IOL Master, and Pentacam. Materials and Methods: In this prospective study, consecutive measurements were performed in two different sessions with the mentioned three devices on 110 eyes of 55 subjects who had no additional ocular pathology except for refraction error. The consistency of flat and steep keratometry, average keratometry, and corneal astigmatism values obtained in both sessions was compared by using intraclass correlation coefficient (ICC. The measurement differences between the devices were statistically compared as well. Results: The mean age of the study subjects was 23.05±3.01 (18-30 years. ICC values of average keratometry measurements obtained in the sessions were 0.996 for Potec PRK-6000 autorefractometer, 0.997 for IOL Master, and 0.999 for Pentacam. There was high compatibility between the three devices in terms of average keratometry values in Bland-Altman analysis. However, there were statistically significant differences between the devices in terms of parameters other than corneal astigmatism. Conclusion: The repeatability of the three devices was found considerably high in keratometry measurements. However, it is not appropriate for these devices to be substituted for each other in keratometry measurements. (Turk J Ophthalmol 2014; 44: 179-83

  16. [Repeated measurement of memory with valenced test items: verbal memory, working memory and autobiographic memory].

    Science.gov (United States)

    Kuffel, A; Terfehr, K; Uhlmann, C; Schreiner, J; Löwe, B; Spitzer, C; Wingenfeld, K

    2013-07-01

    A large number of questions in clinical and/or experimental neuropsychology require the multiple repetition of memory tests at relatively short intervals. Studies on the impact of the associated exercise and interference effects on the validity of the test results are rare. Moreover, hardly any neuropsychological instruments exist to date to record the memory performance with several parallel versions in which the emotional valence of the test material is also taken into consideration. The aim of the present study was to test whether a working memory test (WST, a digit-span task with neutral or negative distraction stimuli) devised by our workgroup can be used with repeated measurements. This question was also examined in parallel versions of a wordlist learning paradigm and an autobiographical memory test (AMT). Both tests contained stimuli with neutral, positive and negative valence. Twenty-four participants completed the memory testing including the working memory test and three versions of a wordlist and the AMT at intervals of a week apiece (measuring points 1. - 3.). The results reveal consistent performances across the three measuring points in the working and autobiographical memory test. The valence of the stimulus material did not influence the memory performance. In the delayed recall of the wordlist an improvement in memory performance over time was seen. The tests on working memory presented and the parallel versions for the declarative and autobiographical memory constitute informal economic instruments within the scope of the measurement repeatability designs. While the WST and AMT are appropriate for study designs with repeated measurements at relatively short intervals, longer intervals might seem more favourable for the use of wordlist learning paradigms. © Georg Thieme Verlag KG Stuttgart · New York.

  17. Characterization of the peripheral blood transcriptome in a repeated measures design using a panel of healthy individuals

    DEFF Research Database (Denmark)

    De Boever, Patrick; Wens, Britt; Forcheh, Anyiawung Chiara

    2014-01-01

    A repeated measures microarray design with 22 healthy, non-smoking volunteers (aging 32. ±. 5. years) was set up to study transcriptome profiles in whole blood samples. The results indicate that repeatable data can be obtained with high within-subject correlation. Probes that could discriminate....... Our study suggests that the blood transcriptome of healthy individuals is reproducible over a time period of several months. © 2013 Elsevier Inc....

  18. Measuring environmental change in forest ecosystems by repeated soil sampling: a North American perspective

    Science.gov (United States)

    Lawrence, Gregory B.; Fernandez, Ivan J.; Richter, Daniel D.; Ross, Donald S.; Hazlett, Paul W.; Bailey, Scott W.; Oiumet, Rock; Warby, Richard A.F.; Johnson, Arthur H.; Lin, Henry; Kaste, James M.; Lapenis, Andrew G.; Sullivan, Timothy J.

    2013-01-01

    Environmental change is monitored in North America through repeated measurements of weather, stream and river flow, air and water quality, and most recently, soil properties. Some skepticism remains, however, about whether repeated soil sampling can effectively distinguish between temporal and spatial variability, and efforts to document soil change in forest ecosystems through repeated measurements are largely nascent and uncoordinated. In eastern North America, repeated soil sampling has begun to provide valuable information on environmental problems such as air pollution. This review synthesizes the current state of the science to further the development and use of soil resampling as an integral method for recording and understanding environmental change in forested settings. The origins of soil resampling reach back to the 19th century in England and Russia. The concepts and methodologies involved in forest soil resampling are reviewed and evaluated through a discussion of how temporal and spatial variability can be addressed with a variety of sampling approaches. Key resampling studies demonstrate the type of results that can be obtained through differing approaches. Ongoing, large-scale issues such as recovery from acidification, long-term N deposition, C sequestration, effects of climate change, impacts from invasive species, and the increasing intensification of soil management all warrant the use of soil resampling as an essential tool for environmental monitoring and assessment. Furthermore, with better awareness of the value of soil resampling, studies can be designed with a long-term perspective so that information can be efficiently obtained well into the future to address problems that have not yet surfaced.

  19. Iterative Weighted Semiparametric Least Squares Estimation in Repeated Measurement Partially Linear Regression Models

    Institute of Scientific and Technical Information of China (English)

    Ge-mai Chen; Jin-hong You

    2005-01-01

    Consider a repeated measurement partially linear regression model with an unknown vector pasemiparametric generalized least squares estimator (SGLSE) ofβ, we propose an iterative weighted semiparametric least squares estimator (IWSLSE) and show that it improves upon the SGLSE in terms of asymptotic covariance matrix. An adaptive procedure is given to determine the number of iterations. We also show that when the number of replicates is less than or equal to two, the IWSLSE can not improve upon the SGLSE.These results are generalizations of those in [2] to the case of semiparametric regressions.

  20. Accuracy and repeatability of an inertial measurement unit system for field-based occupational studies.

    Science.gov (United States)

    Schall, Mark C; Fethke, Nathan B; Chen, Howard; Oyama, Sakiko; Douphrate, David I

    2016-04-01

    The accuracy and repeatability of an inertial measurement unit (IMU) system for directly measuring trunk angular displacement and upper arm elevation were evaluated over eight hours (i) in comparison to a gold standard, optical motion capture (OMC) system in a laboratory setting, and (ii) during a field-based assessment of dairy parlour work. Sample-to-sample root mean square differences between the IMU and OMC system ranged from 4.1° to 6.6° for the trunk and 7.2°-12.1° for the upper arm depending on the processing method. Estimates of mean angular displacement and angular displacement variation (difference between the 90th and 10th percentiles of angular displacement) were observed to change IMU system may serve as an acceptable instrument for directly measuring trunk and upper arm postures in field-based occupational exposure assessment studies with long sampling durations. Practitioner Summary: Few studies have evaluated inertial measurement unit (IMU) systems in the field or over long sampling durations. Results of this study indicate that the IMU system evaluated has reasonably good accuracy and repeatability for use in a field setting over a long sampling duration.

  1. Alcohol intake and colorectal cancer: a comparison of approaches for including repeated measures of alcohol consumption

    DEFF Research Database (Denmark)

    Thygesen, Lau Caspar; Wu, Kana; Grønbaek, Morten

    2008-01-01

    BACKGROUND: In numerous studies, alcohol intake has been found to be positively associated with colorectal cancer risk. However, the majority of studies included only one exposure measurement, which may bias the results if long-term intake is relevant.METHODS: We compared different approaches...... for including repeated measures of alcohol intake among 47,432 US men enrolled in the Health Professionals Follow-up Study. Questionnaires including questions on alcohol intake had been completed in 1986, 1990, 1994, and 1998. The outcome was incident colorectal cancer during follow-up from 1986 to 2002.RESULTS......: During follow-up, 868 members of the cohort experienced colorectal cancer. Baseline, updated, and cumulative average alcohol intakes were positively associated with colorectal cancer, with only minor differences among the approaches. These results support moderately increased risk for intake >30 g...

  2. Information Contents of a Signal at Repeated Positioning Measurements of the Coordinate Measuring Machine (CMM by Laser Interferometer

    Directory of Open Access Journals (Sweden)

    Stejskal Tomáš

    2016-10-01

    Full Text Available The input of this paper lies in displaying possibilities how to determine the condition of a coordinate measuring machine (CMM based on a large number of repeated measurements. The number of repeated measurements exceeds common requirements for determining positioning accuracy. The total offset in the accuracy of spatial positioning consists of partial inaccuracies of individual axes. 6 basic errors may be defined at each axis. In a triaxial set, that translates into 18 errors, to which an offset from the perpendicularity between the axial pairs must be added. Therefore, the combined number of errors in a single position is 21. These errors are systemic and stem from the machine’s geometry. In addition, there are accidental errors to account for as well. Accidental errors can be attributed to vibrations, mass inertness, passive resistance, and in part to fluctuations in temperature. A peculiar set of systemic errors are time-varying errors. The nature of those errors may be reversible, for instance if they result from influence of temperature or elastic deformation. They can be also irreversible, for example as a result of wear and tear or line clogging, due to loosened connection or permanent deformation of a part post collision. A demonstration of thermal equalizing of the machine’s parts may also be observed in case of failure to adhere to a sufficient time interval from the moment the air-conditioning is turned on. Repeated measurements done on a selected axis with linear interferometer can provide complex information on the CMM condition and also on the machine’s interaction with the given technical environment.

  3. Measuring Starlight Deflection during the 2017 Eclipse: Repeating the Experiment that made Einstein Famous

    Science.gov (United States)

    Bruns, Donald

    2016-05-01

    In 1919, astronomers performed an experiment during a solar eclipse, attempting to measure the deflection of stars near the sun, in order to verify Einstein's theory of general relativity. The experiment was very difficult and the results were marginal, but the success made Albert Einstein famous around the world. Astronomers last repeated the experiment in 1973, achieving an error of 11%. In 2017, using amateur equipment and modern technology, I plan to repeat the experiment and achieve a 1% error. The best available star catalog will be used for star positions. Corrections for optical distortion and atmospheric refraction are better than 0.01 arcsec. During totality, I expect 7 or 8 measurable stars down to magnitude 9.5, based on analysis of previous eclipse measurements taken by amateurs. Reference images, taken near the sun during totality, will be used for precise calibration. Preliminary test runs performed during twilight in April 2016 and April 2017 can accurately simulate the sky conditions during totality, providing an accurate estimate of the final uncertainty.

  4. Separating climate-induced mass transfers and instrumental effects from tectonic signal in repeated absolute gravity measurements

    Science.gov (United States)

    Van Camp, M.; Viron, O.; Avouac, J. P.

    2016-05-01

    We estimate the signature of the climate-induced mass transfers in repeated absolute gravity measurements based on satellite gravimetric measurements from the Gravity Recovery and Climate Experiment (GRACE) mission. We show results at the globe scale and compare them with repeated absolute gravity (AG) time behavior in three zones where AG surveys have been published: Northwestern Europe, Canada, and Tibet. For 10 yearly campaigns, the uncertainties affecting the determination of a linear gravity rate of change range 3-4 nm/s2/a in most cases, in the absence of instrumental artifacts. The results are consistent with what is observed for long-term repeated campaigns. We also discuss the possible artifact that can result from using short AG survey to determine the tectonic effects in a zone of high hydrological variability. We call into question the tectonic interpretation of several gravity changes reported from stations in Tibet, in particular the variation observed prior to the 2015 Gorkha earthquake.

  5. ±25ppm repeatable measurement of trapezoidal pulses with 5MHz bandwidth

    CERN Document Server

    AUTHOR|(SzGeCERN)712364; Arpaia, Pasquale; Cerqueira Bastos, Miguel; Martino, Michele

    2015-01-01

    High-quality measurements of pulses are nowadays widely used in fields such as radars, pulsed lasers, electromagnetic pulse generators, and particle accelerators. Whilst literature is mainly focused on fast systems for nanosecond regime with relaxed metrological requirements, in this paper, the high-performance measurement of slower pulses in microsecond regime is faced. In particular, the experimental proof demonstration for a 15 MS/s,_25 ppm repeatable acquisition system to characterize the flat-top of 3 ms rise-time trapezoidal pulses is given. The system exploits a 5MHz bandwidth circuit for analogue signal processing based on the concept of flat-top removal. The requirements, as well as the conceptual and physical designs are illustrated. Simulation results aimed at assessing the circuit performance are also presented. Finally, an experimental case study on the characterization of a pulsed power supply for the klystrons modulators of the Compact Linear Collider (CLIC) under study at CERN is reported. In ...

  6. Role of Repeat Muscle Compartment Pressure Measurements in Chronic Exertional Compartment Syndrome of the Lower Leg

    Science.gov (United States)

    van Zantvoort, Aniek P. M.; de Bruijn, Johan A.; Winkes, Michiel B.; Hoogeveen, Adwin R.; Teijink, Joep A. W.; Scheltinga, Marc R.

    2017-01-01

    Background: The diagnostic gold standard for diagnosing chronic exertional compartment syndrome (CECS) is a dynamic intracompartmental pressure (ICP) measurement of the muscle. The potential role of a repeat ICP (re-ICP) measurement in patients with persistent lower leg symptoms after surgical decompression or with ongoing symptoms after an earlier normal ICP is unknown. Purpose: To study whether re-ICP measurements in patients with persistent CECS-like symptoms of the lower leg may contribute to the diagnosis of CECS after both surgical decompression and a previously normal ICP measurement. Study Design: Case series; Level of evidence, 4. Methods: Charts of patients who underwent re-ICP measurement of lower leg compartments (anterior [ant], deep posterior [dp], and/or lateral [lat] compartments) between 2001 and 2013 were retrospectively studied. CECS was diagnosed on the basis of generally accepted cutoff pressures for newly onset CECS (Pedowitz criteria: ICP at rest ≥15 mmHg, ≥30 mmHg after 1 minute, or ≥20 mmHg 5 minutes after a provocative test). Factors predicting recurrent CECS after surgery or after a previously normal ICP measurement were analyzed. Results: A total of 1714 ICP measurements were taken in 1513 patients with suspected CECS over a 13-year observation period. In all, 201 (12%) tests were re-ICP measurements for persistent lower leg symptoms. Based on the proposed ICP cutoff values, CECS recurrence was diagnosed in 16 of 62 previously operated compartments (recurrence rate, 26%; 53 patients [64% female]; median age, 24 years; age range, 15-78 years). Recurrence rates were not different among the 3 lower leg CECS compartments (ant-CECS, 17%; dp-CECS, 33%; lat-CECS, 30%; χ2 = 1.928, P = .381). Sex (χ2 = 0.058, P = .810), age (U = 378, z = 1.840, P = .066), bilaterality (χ2 = 0.019, P = .889), and prefasciotomy ICP did not predict recurrence. Re-ICP measurements evaluating 20 compartments with previously normal ICP measurements (15

  7. Graphic Methods for Interpreting Longitudinal Dyadic Patterns From Repeated-Measures Actor-Partner Interdependence Models

    DEFF Research Database (Denmark)

    Perry, Nicholas; Baucom, Katherine; Bourne, Stacia

    2017-01-01

    Researchers commonly use repeated-measures actor–partner interdependence models (RM-APIM) to understand how romantic partners change in relation to one another over time. However, traditional interpretations of the results of these models do not fully or correctly capture the dyadic temporal...... patterns estimated in RM-APIM. Interpretation of results from these models largely focuses on the meaning of single-parameter estimates in isolation from all the others. However, considering individual coefficients separately impedes the understanding of how these associations combine to produce...... to improve the understanding and presentation of dyadic patterns of association described by standard RM-APIMs. The current article briefly reviews the conceptual foundations of RM-APIMs, demonstrates how change-as-outcome RM-APIMs and VFDs can aid interpretation of standard RM-APIMs, and provides a tutorial...

  8. Inmate responses to prison-based drug treatment: a repeated measures analysis.

    Science.gov (United States)

    Welsh, Wayne N

    2010-06-01

    Using a sample of 347 prison inmates and general linear modeling (GLM) repeated measures analyses, this paper examined during-treatment responses (e.g., changes in psychological and social functioning) to prison-based TC drug treatment. These effects have rarely been examined in previous studies, and never with a fully multivariate model accounting for within-subjects effects (changes over time), between-subjects effects (e.g., levels of risk and motivation), and within/between-subjects interactions (timexriskxmotivation). The results provide evidence of positive inmate change in response to prison TC treatment, but the patterns of results varied depending upon: (a) specific indicators of psychological and social functioning, motivation, and treatment process; (b) the time periods examined (1, 6, and 12 months during treatment); and (c) baseline levels of risk and motivation. Significant interactions between time and type of inmate suggest important new directions for research, theory, and practice in offender-based substance abuse treatment.

  9. Measurement repeatability of tibial tuberosity-trochlear groove offset distance in red fox (Vulpes vulpes) cadavers

    NARCIS (Netherlands)

    Miles, J.E.; Jensen, B.R.; Kirpensteijn, J.; Svalastoga, E.L.; Eriksen, T.

    2013-01-01

    Abstract OBJECTIVE: To describe CT image reconstruction criteria for measurement of the tibial tuberosity-trochlear groove (TT-TG) offset distance, evaluate intra- and inter-reconstruction repeatability, and identify key sources of error in the measurement technique, as determined in vulpine hind li

  10. Hierarchical linear model: thinking outside the traditional repeated-measures analysis-of-variance box.

    Science.gov (United States)

    Lininger, Monica; Spybrook, Jessaca; Cheatham, Christopher C

    2015-04-01

    Longitudinal designs are common in the field of athletic training. For example, in the Journal of Athletic Training from 2005 through 2010, authors of 52 of the 218 original research articles used longitudinal designs. In 50 of the 52 studies, a repeated-measures analysis of variance was used to analyze the data. A possible alternative to this approach is the hierarchical linear model, which has been readily accepted in other medical fields. In this short report, we demonstrate the use of the hierarchical linear model for analyzing data from a longitudinal study in athletic training. We discuss the relevant hypotheses, model assumptions, analysis procedures, and output from the HLM 7.0 software. We also examine the advantages and disadvantages of using the hierarchical linear model with repeated measures and repeated-measures analysis of variance for longitudinal data.

  11. Hierarchical Linear Model: Thinking Outside the Traditional Repeated-Measures Analysis-of-Variance Box

    Science.gov (United States)

    Lininger, Monica; Spybrook, Jessaca; Cheatham, Christopher C.

    2015-01-01

    Longitudinal designs are common in the field of athletic training. For example, in the Journal of Athletic Training from 2005 through 2010, authors of 52 of the 218 original research articles used longitudinal designs. In 50 of the 52 studies, a repeated-measures analysis of variance was used to analyze the data. A possible alternative to this approach is the hierarchical linear model, which has been readily accepted in other medical fields. In this short report, we demonstrate the use of the hierarchical linear model for analyzing data from a longitudinal study in athletic training. We discuss the relevant hypotheses, model assumptions, analysis procedures, and output from the HLM 7.0 software. We also examine the advantages and disadvantages of using the hierarchical linear model with repeated measures and repeated-measures analysis of variance for longitudinal data. PMID:25875072

  12. Power analysis for multivariate and repeated measures designs: a flexible approach using the SPSS MANOVA procedure.

    Science.gov (United States)

    D'Amico, E J; Neilands, T B; Zambarano, R

    2001-11-01

    Although power analysis is an important component in the planning and implementation of research designs, it is often ignored. Computer programs for performing power analysis are available, but most have limitations, particularly for complex multivariate designs. An SPSS procedure is presented that can be used for calculating power for univariate, multivariate, and repeated measures models with and without time-varying and time-constant covariates. Three examples provide a framework for calculating power via this method: an ANCOVA, a MANOVA, and a repeated measures ANOVA with two or more groups. The benefits and limitations of this procedure are discussed.

  13. Australian House Prices: A Comparison of Hedonic and Repeat-sales Measures

    OpenAIRE

    James Hansen

    2006-01-01

    House prices are intrinsically difficult to measure due to changes in the composition of properties sold through time and changes in the quality of housing. I provide an overview of the theoretical nature of these issues and consider how regression-based measures of house prices – hedonic and repeat-sales measures – can control for compositional and quality change. I then explore whether these regression-based alternatives can provide accurate estimates of pure house price changes in the Aust...

  14. Recent crustal movement determined from repeat surveying—results from southeastern and southwestern Australia

    Science.gov (United States)

    Wellman, Peter

    1983-09-01

    First-order geodetic measurements have been repeated in seismically active areas in southeastern and southwestern Australia. In both areas significant crustal movement is detected. The crustal movements give principal axes of compression parallel to those of in-situ stress measurements, and roughly consistent with those of earthquake focal mechanisms. The seismic moment rates calculated from the measured strain rates are higher than those calculated from the historic earthquake record. In southeastern Australia the strain rate is about 50 × 10 -9 yr -1 over the whole area investigated, but with a gradually changing principal axis of compression. The rate of change of direction is similar to that found in Japan. In southwestern Australia the strain is detected only along zones of weakness, and the principal axis of compression is fairly uniformly east-west. The difference in the pattern of detected strain, together with a difference in the size of the areas in regional isostatic compensation, and a difference in average heat flow, are all consistent with a relatively weak, hot crust in southeastern Australia, and a relatively strong, cold crust in southwestern Australia.

  15. Accuracy and repeatability of anthropometric facial measurements using cone beam computed tomography

    NARCIS (Netherlands)

    Fourie, Zacharias; Damstra, Janalt; Gerrits, Peter O.; Ren, Yijin

    2011-01-01

    Objective: The purpose of this study was to determine the accuracy and repeatability of linear anthropometric measurements on the soft tissue surface model generated from cone beam computed tomography scans. Materials and Methods: The study sample consisted of seven cadaver heads. The accuracy and r

  16. Cross-trimester repeated measures testing for Down's syndrome screening: an assessment.

    LENUS (Irish Health Repository)

    Wright, D

    2010-07-01

    To provide estimates and confidence intervals for the performance (detection and false-positive rates) of screening for Down\\'s syndrome using repeated measures of biochemical markers from first and second trimester maternal serum samples taken from the same woman.

  17. REPEATABILITY OF THE SUGAR ABSORPTION TEST, USING LACTULOSE AND MANNITOL, FOR MEASURING INTESTINAL PERMEABILITY FOR SUGARS

    NARCIS (Netherlands)

    VANELBURG, RM; UIL, JJ; KOKKE, FTM; MULDER, AM; VANDEBROEK, WGM; MULDER, CJJ; HEYMANS, HSA

    1995-01-01

    Differential sugar-absorption tests for measuring intestinal permeability for sugars have been studied in a variety of gastrointestinal diseases. Their use in general practice has been hampered by a lack of data on reference values and repeatability of the test and the laboratory assay. In this stud

  18. The Multilevel Approach to Repeated Measures for Complete and Incomplete Data

    NARCIS (Netherlands)

    Maas, CJM; Snijders, TAB

    2003-01-01

    Repeated measurements often are analyzed by multivariate analysis of variance (MANOVA). An alternative approach is provided by multilevel analysis, also called the hierarchical linear model (HLM), which makes use of random coefficient models. This paper is a tutorial which indicates that the HLM can

  19. Repeatability and reproducibility of measurements of the suburethral tape location obtained in pelvic floor ultrasound performed with a transvaginal probe

    Directory of Open Access Journals (Sweden)

    Maria Magdalena Dresler

    2017-06-01

    Full Text Available Introduction: Implants used to treat patients with urogynecological conditions are well visible in US examination. The position of the suburethral tape (sling is determined in relation to the urethra or the pubic symphysis. Aim of the study: The study was aimed at assessing the accuracy of measurements determining suburethral tape location obtained in pelvic US examination performed with a transvaginal probe. Material and methods: The analysis covered the results of sonographic measurements obtained according to a standardized technique in women referred for urogynecological diagnostics. Data from a total of 68 patients were used to analyse the repeatability and reproducibility of results obtained on the same day. Results: The intraclass correlation coefficient for the repeatability and reproducibility of the sonographic measurements of suburethral tape location obtained with a transvaginal probe ranged from 0.6665 to 0.9911. The analysis of the measurements confirmed their consistency to be excellent or good. Conclusions: Excellent and good repeatability and reproducibility of the measurements of the suburethral tape location obtained in a pelvic ultrasound performed with a transvaginal probe confirm the test’s validity and usefulness for clinical and academic purposes.

  20. Repeatability of Volume and Regional Body Composition Measurements of the Lower Limb Using Dual-energy X-ray Absorptiometry

    DEFF Research Database (Denmark)

    Gjorup, Caroline A; Zerahn, Bo; Juul, Sarah

    2016-01-01

    Lower limb lymphedema is a dynamic condition in which tissue composition and volume measurements are affected. Various definitions of lower limb lymphedema exist but volume differences between the limbs are widely used. It is therefore necessary to have a readily available noninvasive measurement...... of agreement on the Bland-Altman plots. These results confirm DXA to be a highly repeatable method for volume and tissue composition measurements of the lower limb. In a population at risk of lymphedema, DXA offers a clinically readily available noninvasive method allowing multiple measurements of volume...... and tissue composition on a routine basis, important for diagnosing, monitoring, managing, and researching lymphedema....

  1. Repeated Activation of a CS-US-Contingency Memory Results in Sustained Conditioned Responding.

    Science.gov (United States)

    Joos, Els; Vansteenwegen, Debora; Vervliet, Bram; Hermans, Dirk

    2013-01-01

    Individuals seem to differ in conditionability, i.e., the ease by which the contingent presentation of two stimuli will lead to a conditioned response. In contemporary learning theory, individual differences in the etiology and maintenance of anxiety disorders are, among others, explained by individual differences in temperamental variables (Mineka and Zinbarg, 2006). One such individual difference variable is how people process a learning experience when the conditioning stimuli are no longer present. Repeatedly thinking about the conditioning experience, as in worry or rumination, might prolong the initial (fear) reactions and as such, might leave certain individuals more vulnerable to developing an anxiety disorder. However, in human conditioning research, relatively little attention has been devoted to the processing of a memory trace after its initial acquisition, despite its potential influences on subsequent performance. Post-acquisition processing can be induced by mental reiteration of a conditioned stimulus-unconditioned stimulus (CS-US)-contingency. Using a human conditioned suppression paradigm, we investigated the effect of repeated activations of a CS-US-contingency memory on the level of conditioned responding at a later test. Results of three experiments showed more sustained responding to a "rehearsed" CS+ as compared to a "non-rehearsed" CS+. Moreover, the second experiment showed no effect of rehearsal when only the CS was rehearsed instead of the CS-US-contingency. The third experiment demonstrated that mental CS-US-rehearsal has the same effect regardless of whether it was cued by the CS and a verbal reference to the US or by a neutral signal, making the rehearsal "purely mental." In sum, it was demonstrated that post-acquisition activation of a CS-US-contingency memory can impact conditioned responding, underlining the importance of post-acquisition processes in conditioning. This might indicate that individuals who are more prone to mentally

  2. Repeated activation of a CS-US-contingency memory results in sustained conditioned responding

    Directory of Open Access Journals (Sweden)

    Els eJoos

    2013-05-01

    Full Text Available Individuals seem to differ in conditionability, i.e., the ease by which the contingent presentation of two stimuli will lead to a conditioned response. In contemporary learning theory, individual differences in the etiology and maintenance of anxiety disorders are, among others, explained by individual differences in temperamental variables (Mineka & Zinbarg, 2006. One such individual difference variable is how people process a learning experience when the conditioning stimuli are no longer present. Repeatedly thinking about the conditioning experience, as in worry or rumination, might prolong the initial (fear reactions and as such, might leave certain individuals more vulnerable to developing an anxiety disorder.However, in human conditioning research, relatively little attention has been devoted to the processing of a memory trace after its initial acquisition, despite its potential influences on subsequent performance. Post-acquisition processing can be induced by mental reiteration of a CS-US-contingency. Using a human conditioned suppression paradigm, we investigated the effect of repeated activations of a CS-US-contingency memory on the level of conditioned responding at a later test. Results of three experiments showed more sustained responding to a ‘rehearsed’ CS+ as compared to a ‘non-rehearsed’ CS+. Moreover, the second experiment showed no effect of rehearsal when only the CS was rehearsed instead of the CS-US-contingency. The third experiment demonstrated that mental CS-US-rehearsal has the same effect regardless of whether it was cued by the CS and a verbal reference to the US or by a neutral signal, making the rehearsal ‘purely mental’. In sum, it was demonstrated that post-acquisition activation of a CS-US-contingency memory can impact conditioned responding, underlining the importance of post-acquisition processes in conditioning. This might indicate that individuals who are more prone to mentally rehearse

  3. Comparison of Central Corneal Thickness Measurements by Ultrasonic Pachymetry and Orbscan II Corneal Topography and Evaluation of Ultrasonic Pachymetry Repeatability

    Directory of Open Access Journals (Sweden)

    Semra Tiryaki Demir

    2014-08-01

    Full Text Available Objectives: Comparison of central corneal thickness (CCT measurements by ultrasonic pachymetry and Orbscan II corneal topography and evaluation of ultrasonic pachymetry repeatability for same observer. Materials and Methods: The study included 132, 82, and 80 eyes of 66 patients with primary open-angle glaucoma (POAG, 41 patients with ocular hypertension (OHT, and 40 controls, respectively. All subjects were subjected to routine ophthalmic examination. Orbscan II (Bausch&Lomb corneal topography and ultrasonic pachymetry (Nidek Ultrasonic Pachymetry UP-1000 were used for measurement of CCT. ANOVA (Turkey test was used for variable distribution, paired sample t-test was used for repeated measurements, and the analyses were done by SPSS 20.0. Results: Mean CCT was 558.9±37.2 µm by ultrasonic pachymetry and 553.4±37 µm by corneal topography. There was a significant difference between the two measurements (p0.05. CCT was 555±39.2 µm, 564.3±28.4 µm, and 559.7±41.5 µm by ultrasonic pachymetry in POAG, OHT, and control subjects, respectively; CCT was 550.3±38.3 µm, 558.5±28 µm, and 553.2±42.5 µm by Orbscan II corneal topography in POAG, OHT, and control subjects, respectively. There was a significant linear correlation between Orbscan II corneal topography and ultrasonic pachymetry in CCT measurements (r=0.975, p<0.0001. Repeatability of ultrasonic pachymetry for same observer was (ICC value 0.990. Conclusion: There is a significant correlation between Orbscan II corneal topography and ultrasonic pachymetry in CCT measurements. These two methods of measurements should not be substituted for each other, since ultrasonic pachymetry measures CCT greater than Orbscan II corneal topography. Repeatability of ultrasonic pachymetry for same observer is very high. (Turk J Ophthalmol 2014; 44: 263-7

  4. Incomplete quality of life data in lung transplant research: comparing cross sectional, repeated measures ANOVA, and multi-level analysis

    Directory of Open Access Journals (Sweden)

    van der Bij Wim

    2005-09-01

    Full Text Available Abstract Background In longitudinal studies on Health Related Quality of Life (HRQL it frequently occurs that patients have one or more missing forms, which may cause bias, and reduce the sample size. Aims of the present study were to address the problem of missing data in the field of lung transplantation (LgTX and HRQL, to compare results obtained with different methods of analysis, and to show the value of each type of statistical method used to summarize data. Methods Results from cross-sectional analysis, repeated measures on complete cases (ANOVA, and a multi-level analysis were compared. The scores on the dimension 'energy' of the Nottingham Health Profile (NHP after transplantation were used to illustrate the differences between methods. Results Compared to repeated measures ANOVA, the cross-sectional and multi-level analysis included more patients, and allowed for a longer period of follow-up. In contrast to the cross sectional analyses, in the complete case analysis, and the multi-level analysis, the correlation between different time points was taken into account. Patterns over time of the three methods were comparable. In general, results from repeated measures ANOVA showed the most favorable energy scores, and results from the multi-level analysis the least favorable. Due to the separate subgroups per time point in the cross-sectional analysis, and the relatively small number of patients in the repeated measures ANOVA, inclusion of predictors was only possible in the multi-level analysis. Conclusion Results obtained with the various methods of analysis differed, indicating some reduction of bias took place. Multi-level analysis is a useful approach to study changes over time in a data set where missing data, to reduce bias, make efficient use of available data, and to include predictors, in studies concerning the effects of LgTX on HRQL.

  5. Repeatability and reproducibility of optic nerve head perfusion measurements using optical coherence tomography angiography

    Science.gov (United States)

    Chen, Chieh-Li; Bojikian, Karine D.; Xin, Chen; Wen, Joanne C.; Gupta, Divakar; Zhang, Qinqin; Mudumbai, Raghu C.; Johnstone, Murray A.; Chen, Philip P.; Wang, Ruikang K.

    2016-06-01

    Optical coherence tomography angiography (OCTA) has increasingly become a clinically useful technique in ophthalmic imaging. We evaluate the repeatability and reproducibility of blood perfusion in the optic nerve head (ONH) measured using optical microangiography (OMAG)-based OCTA. Ten eyes from 10 healthy volunteers are recruited and scanned three times with a 68-kHz Cirrus HD-OCT 5000-based OMAG prototype system (Carl Zeiss Meditec Inc., Dublin, California) centered at the ONH involving two separate visits within six weeks. Vascular images are generated with OMAG processing by detecting the differences in OCT signals between consecutive B-scans acquired at the same retina location. ONH perfusion is quantified as flux, vessel area density, and normalized flux within the ONH for the prelaminar, lamina cribrosa, and the full ONH. Coefficient of variation (CV) and intraclass correlation coefficient (ICC) are used to evaluate intravisit and intervisit repeatability, and interobserver reproducibility. ONH perfusion measurements show high repeatability [CV≤3.7% (intravisit) and ≤5.2% (intervisit)] and interobserver reproducibility (ICC≤0.966) in all three layers by three metrics. OCTA provides a noninvasive method to visualize and quantify ONH perfusion in human eyes with excellent repeatability and reproducibility, which may add additional insight into ONH perfusion in clinical practice.

  6. Using the Monte Carlo Simulation Methods in Gauge Repeatability and Reproducibility of Measurement System Analysis

    Directory of Open Access Journals (Sweden)

    Tsu-Ming Yeh

    2013-10-01

    Full Text Available Measurements are required to maintain the consistent quality of all finished and semi-finished products in a production line. Many firms in the automobile and general precision industries apply the TS 16949:2009 Technical Specifications and Measurement System Analysis (MSA manual to establish measurement systems. This work is undertaken to evaluate gauge repeatability and reproducibility (GR&R to verify the measuring ability and quality of the measurement frame, as well as to continuously improve and maintain the verification process. Nevertheless, the implementation of GR&R requires considerable time and manpower, and is likely to affect production adversely. In addition, the evaluation value for GR&R is always different owing to the sum of man-made and machine-made variations. Using a Monte Carlo simulation and the prediction of the repeatability and reproducibility of the measurement system analysis, this study aims to determine the distribution of %GR&R and the related number of distinct categories (ndc. This study uses two case studies of an automobile parts manufacturer and the combination of a Monte Carlo simulation, statistical bases, and the prediction of the repeatability and reproducibility of the measurement system analysis to determine the probability density function, the distribution of %GR&R, and the related number of distinct categories (ndc. The method used in this study could evaluate effectively the possible range of the GR&R of the measurement capability, in order to establish a prediction model for the evaluation of the measurement capacity of a measurement system.

  7. Repeated measures of serum glucose and insulin in relation to postmenopausal breast cancer.

    Science.gov (United States)

    Kabat, Geoffrey C; Kim, Mimi; Caan, Bette J; Chlebowski, Rowan T; Gunter, Marc J; Ho, Gloria Y F; Rodriguez, Beatriz L; Shikany, James M; Strickler, Howard D; Vitolins, Mara Z; Rohan, Thomas E

    2009-12-01

    Experimental and epidemiological evidence suggests that circulating glucose and insulin may play a role in breast carcinogenesis. However, few cohort studies have examined breast cancer risk in association with glucose and insulin levels, and studies to date have had only baseline measurements of exposure. We conducted a longitudinal study of postmenopausal breast cancer risk using the 6% random sample of women in the Women's Health Initiative clinical trials whose fasting blood samples, provided at baseline and at years 1, 3 and 6, were analyzed for glucose and insulin. In addition, a 1% sample of women in the observational study, who had glucose and insulin measured in fasting blood samples drawn at baseline and in year 3, were included in the analysis. We used Cox proportional hazards models to estimate hazard ratios and 95% confidence intervals for the association of baseline and follow-up measurements of serum glucose and insulin with breast cancer risk. All statistical tests were 2-sided. Among 5,450 women with baseline serum glucose and insulin values, 190 incident cases of breast cancer were ascertained over a median of 8.0 years of follow-up. The highest tertile of baseline insulin, relative to the lowest, was associated with a 2-fold increase in risk in the total population (multivariable hazard ratio 2.22, 95% confidence interval 1.39-3.53) and with a 3-fold increase in risk in women who were not enrolled in the intervention arm of any clinical trial (multivariable hazard ratio 3.15, 95% confidence interval 1.61-6.17). Glucose levels showed no association with risk. Analysis of the repeated measurements supported the results of the baseline analysis. These data suggest that elevated serum insulin levels may be a risk factor for postmenopausal breast cancer.

  8. Corneal Topographic and Aberrometric Measurements Obtained with a Multidiagnostic Device in Healthy Eyes: Intrasession Repeatability

    Directory of Open Access Journals (Sweden)

    David P. Piñero

    2017-01-01

    Full Text Available Purpose. To evaluate the intrasession repeatability of corneal curvature, eccentricity, and aberrometric measurements obtained with a multidiagnostic device in healthy eyes. Methods. This study enrolled 107 eyes of 107 patients ranging in age from 23 to 65 years. All of them underwent a complete anterior segment examination with the VX120 system (Visionix-Luneau Technologies, Chartres, France. Three consecutive measurements were obtained. The within-subject standard deviation (Sw, intrasubject precision (1.96×Sw, and intraclass correlation coefficient (ICC were calculated. Results. All Sw for corneal power measurements were below 0.26 D, with ICC above 0.982. The Sw for corneal astigmatism at different areas (3, 5, and 7 mm was below 0.21 D, with ICC above 0.913. Concerning the axis of astigmatism, its Sw was below 11.27°, with ICC above 0.975. The Sw and ICC for corneal eccentricity were 0.067 and 0.957, respectively. The Sw and ICC for high-order aberration root mean square (RMS were 0.048 µm and 0.901, respectively. For 3rd- and 4th-order aberrometric parameters, all Sw were below 0.037 µm and all ICC were higher than 0.84, except for quadrafoil RMS (ICC: 0.689. Conclusions. The multidiagnostic device evaluated is able to provide consistent measurements of corneal power, eccentricity, and third- and fourth-order aberrations in healthy eyes.

  9. The Repeatability Assessment of Three-Dimensional Capsule-Intraocular Lens Complex Measurements by Means of High-Speed Swept-Source Optical Coherence Tomography

    Science.gov (United States)

    Chang, Pingjun; Li, Jin; Savini, Giacomo; Huang, Jinhai; Huang, Shenghai; Zhao, Yinying; Liao, Na; Lin, Lei; Yu, Xiaoyu; Zhao, Yun-e

    2015-01-01

    Purpose To rebuild the three-dimensional (3-D) model of the anterior segment by high-speed swept-source optical coherence tomography (SSOCT) and evaluate the repeatability of measurement for the parameters of capsule-intraocular lens (C-IOL) complex. Methods Twenty-two pseudophakic eyes from 22 patients were enrolled. Three continuous SSOCT measurements were performed in all eyes and the tomograms obtained were used for 3-D reconstruction. The output data were used to evaluate the measurement repeatability. The parameters included postoperative aqueous depth (PAD), the area and diameter of the anterior capsule opening (Area and D), IOL tilt (IOL-T), horizontal, vertical, and space decentration of the IOL, anterior capsule opening, and IOL-anterior capsule opening. Results PAD, IOL-T, Area, D, and all decentration measurements showed high repeatability. Repeated measure analysis showed there was no statistically significant difference among the three continuous measurements (all P > .05). Pearson correlation analysis showed high correlation between each pair of them (all r >0.90, P<0.001). ICCs were all more than 0.9 for all parameters. The 95% LoAs of all parameters were narrow for comparison of three measurements, which showed high repeatability for three measurements. Conclusion SSOCT is available to be a new method for the 3-D measurement of C-IOL complex after cataract surgery. This method presented high repeatability in measuring the parameters of the C-IOL complex. PMID:26600254

  10. Validity and repeatability of three in-shoe pressure measurement systems.

    Science.gov (United States)

    Price, Carina; Parker, Daniel; Nester, Christopher

    2016-05-01

    In-shoe pressure measurement devices are used in research and clinic to quantify plantar foot pressures. Various devices are available, differing in size, sensor number and type; therefore accuracy and repeatability. Three devices (Medilogic, Tekscan and Pedar) were examined in a 2 day×3 trial design, quantifying insole response to regional and whole insole loading. The whole insole protocol applied an even pressure (50-600kPa) to the insole surface for 0-30s in the Novel TruBlue™ device. The regional protocol utilised cylinders with contact surfaces of 3.14 and 15.9cm(2) to apply pressures of 50 and 200kPa. The validity (% difference and Root Mean Square Error: RMSE) and repeatability (Intra-Class Correlation Coefficient: ICC) of the applied pressures (whole insole) and contact area (regional) were outcome variables. Validity of the Pedar system was highest (RMSE 2.6kPa; difference 3.9%), with the Medilogic (RMSE 27.0kPa; difference 13.4%) and Tekscan (RMSE 27.0kPa; difference 5.9%) systems displaying reduced validity. The average and peak pressures demonstrated high between-day repeatability for all three systems and each insole size (ICC≥0.859). The regional contact area % difference ranged from -97 to +249%, but the ICC demonstrated medium to high between-day repeatability (ICC≥0.797). Due to the varying responses of the systems, the choice of an appropriate pressure measurement device must be based on the loading characteristics and the outcome variables sought. Medilogic and Tekscan were most effective between 200 and 300kPa; Pedar performed well across all pressures. Contact area was less precise, but relatively repeatable for all systems.

  11. REPEATED MEASURES ANALYSIS OF CHANGES IN PHOTOSYNTHETIC EFFICIENCY IN SOUR CHERRY DURING WATER DEFICIT

    Directory of Open Access Journals (Sweden)

    Marija Viljevac

    2012-06-01

    Full Text Available The objective of this study was to investigate changes in photosynthetic efficiency applying repeated measures ANOVA using the photosynthetic performance index (PIABS of the JIP-test as a vitality parameter in seven genotypes of sour cherry (Prunus cerasus, L. during 10 days of continuous water deficit. Both univariate and multivariate ANOVA repeated measures revealed highly significant time effect (Days and its subsequent interactions with genotype and water deficit. However, the multivariate Pillai’s trace test detected the interaction Time × Genotype × Water deficit as not significant. According to the Tukey’s Studentized Range (HSD test, differences between the control and genotypes exposed to water stress became significant on the fourth day of the experiment, indicating that the plants on the average, began to lose their photosynthetic efficiency four days after being exposed to water shortage. It corroborates previous findings in other species that PIABS is very sensitive tool for detecting drought stress.

  12. Comparison of Repeated Measurement Design and Mixed Models in Evaluation of the Entonox Effect on Labor Pain

    Directory of Open Access Journals (Sweden)

    Nasim Karimi

    2017-01-01

    Full Text Available Background & objectives: In many medical studies, the response variable is measured repeatedly over time to evaluate the treatment effect that is known as longitudinal study. The analysis method for this type of data is repeated measures ANOVA that uses only one correlation structure and the results are not valid with inappropriate correlation structure. To avoid this problem, a convenient alternative is mixed models. So, the aim of this study was to compare of mixed and repeated measurement models for examination of the Entonox effect on the labor pain. Methods: This experimental study was designed to compare the effect of Entonox and oxygen inhalation on pain relief between two groups. Data were analyzed using repeated measurement and mixed models with different correlation structures. Selection and comparison of proper correlation structures performed using Akaike information criterion, Bayesian information criterion and restricted log-likelihood. Data were analyzed using SPSS-22. Results: Results of our study showed that all variables containing analgesia methods, labor duration of the first and second stages, and time were significant in these tests. In mixed model, heterogeneous first-order autoregressive, first-order autoregressive, heterogeneous Toeplitz and unstructured correlation structures were recognized as the best structures. Also, all variables were significant in these structures. Unstructured variance covariance matrix was recognized as the worst structure and labor duration of the first and second stages was not significant in this structure. Conclusions: This study showed that the Entonox inhalation has a significant effect on pain relief in primiparous and it is confirmed by all of the models.

  13. Analysis of oligonucleotide array experiments with repeated measures using mixed models.

    Science.gov (United States)

    Li, Hao; Wood, Constance L; Getchell, Thomas V; Getchell, Marilyn L; Stromberg, Arnold J

    2004-12-30

    Two or more factor mixed factorial experiments are becoming increasingly common in microarray data analysis. In this case study, the two factors are presence (Patients with Alzheimer's disease) or absence (Control) of the disease, and brain regions including olfactory bulb (OB) or cerebellum (CER). In the design considered in this manuscript, OB and CER are repeated measurements from the same subject and, hence, are correlated. It is critical to identify sources of variability in the analysis of oligonucleotide array experiments with repeated measures and correlations among data points have to be considered. In addition, multiple testing problems are more complicated in experiments with multi-level treatments or treatment combinations. In this study we adopted a linear mixed model to analyze oligonucleotide array experiments with repeated measures. We first construct a generalized F test to select differentially expressed genes. The Benjamini and Hochberg (BH) procedure of controlling false discovery rate (FDR) at 5% was applied to the P values of the generalized F test. For those genes with significant generalized F test, we then categorize them based on whether the interaction terms were significant or not at the alpha-level (alphanew = 0.0033) determined by the FDR procedure. Since simple effects may be examined for the genes with significant interaction effect, we adopt the protected Fisher's least significant difference test (LSD) procedure at the level of alphanew to control the family-wise error rate (FWER) for each gene examined. A linear mixed model is appropriate for analysis of oligonucleotide array experiments with repeated measures. We constructed a generalized F test to select differentially expressed genes, and then applied a specific sequence of tests to identify factorial effects. This sequence of tests applied was designed to control for gene based FWER.

  14. A Network-Based Algorithm for Clustering Multivariate Repeated Measures Data

    Science.gov (United States)

    Koslovsky, Matthew; Arellano, John; Schaefer, Caroline; Feiveson, Alan; Young, Millennia; Lee, Stuart

    2017-01-01

    The National Aeronautics and Space Administration (NASA) Astronaut Corps is a unique occupational cohort for which vast amounts of measures data have been collected repeatedly in research or operational studies pre-, in-, and post-flight, as well as during multiple clinical care visits. In exploratory analyses aimed at generating hypotheses regarding physiological changes associated with spaceflight exposure, such as impaired vision, it is of interest to identify anomalies and trends across these expansive datasets. Multivariate clustering algorithms for repeated measures data may help parse the data to identify homogeneous groups of astronauts that have higher risks for a particular physiological change. However, available clustering methods may not be able to accommodate the complex data structures found in NASA data, since the methods often rely on strict model assumptions, require equally-spaced and balanced assessment times, cannot accommodate missing data or differing time scales across variables, and cannot process continuous and discrete data simultaneously. To fill this gap, we propose a network-based, multivariate clustering algorithm for repeated measures data that can be tailored to fit various research settings. Using simulated data, we demonstrate how our method can be used to identify patterns in complex data structures found in practice.

  15. On the repeated measures designs and sample sizes for randomized controlled trials.

    Science.gov (United States)

    Tango, Toshiro

    2016-04-01

    For the analysis of longitudinal or repeated measures data, generalized linear mixed-effects models provide a flexible and powerful tool to deal with heterogeneity among subject response profiles. However, the typical statistical design adopted in usual randomized controlled trials is an analysis of covariance type analysis using a pre-defined pair of "pre-post" data, in which pre-(baseline) data are used as a covariate for adjustment together with other covariates. Then, the major design issue is to calculate the sample size or the number of subjects allocated to each treatment group. In this paper, we propose a new repeated measures design and sample size calculations combined with generalized linear mixed-effects models that depend not only on the number of subjects but on the number of repeated measures before and after randomization per subject used for the analysis. The main advantages of the proposed design combined with the generalized linear mixed-effects models are (1) it can easily handle missing data by applying the likelihood-based ignorable analyses under the missing at random assumption and (2) it may lead to a reduction in sample size, compared with the simple pre-post design. The proposed designs and the sample size calculations are illustrated with real data arising from randomized controlled trials.

  16. Results of repeated transsphenoidal surgery in Cushing's disease. Long-term follow-up.

    Science.gov (United States)

    Valderrábano, Pablo; Aller, Javier; García-Valdecasas, Leopoldo; García-Uría, José; Martín, Laura; Palacios, Nuria; Estrada, Javier

    2014-04-01

    Transsphenoidal surgery (TSS) is the treatment of choice for Cushing's disease (CD). However, the best treatment option when hypercortisolism persists or recurs remains unknown. The aim of this study was to analyze the short and long-term outcome of repeat TSS in this situation and to search for response predictors. Data from 26 patients with persistent (n=11) or recurrent (n=15) hypercortisolism who underwent repeat surgery by a single neurosurgeon between 1982 and 2009 were retrospectively analyzed. Remission was defined as normalization of urinary free cortisol (UFC) levels, and recurrence as presence of elevated UFC levels after having achieved remission. The following potential outcome predictors were analyzed: adrenal status (persistence or recurrence) after initial TSS, tumor identification in imaging tests, degree of hypercortisolism before repeat TSS, same/different surgeon in both TSS, and time to repeat surgery. Immediate postoperative remission was achieved in 12 patients (46.2%). Five of the 10 patients with available follow-up data relapsed after surgery (median time to recurrence, 13 months). New hormone deficiencies were seen in seven patients (37%), and two patients had cerebrospinal fluid leakage. No other major complications occurred. None of the preoperative factors analyzed was predictive of surgical outcome. When compared to initial surgery, repeat TSS for CD is associated to a lower remission rate and a higher risk of recurrence and complications. Further studies are needed to define outcome predictors. Copyright © 2013 SEEN. Published by Elsevier Espana. All rights reserved.

  17. Analyzing repeated measures semi-continuous data, with application to an alcohol dependence study.

    Science.gov (United States)

    Liu, Lei; Strawderman, Robert L; Johnson, Bankole A; O'Quigley, John M

    2016-02-01

    Two-part random effects models (Olsen and Schafer,(1) Tooze et al.(2)) have been applied to repeated measures of semi-continuous data, characterized by a mixture of a substantial proportion of zero values and a skewed distribution of positive values. In the original formulation of this model, the natural logarithm of the positive values is assumed to follow a normal distribution with a constant variance parameter. In this article, we review and consider three extensions of this model, allowing the positive values to follow (a) a generalized gamma distribution, (b) a log-skew-normal distribution, and (c) a normal distribution after the Box-Cox transformation. We allow for the possibility of heteroscedasticity. Maximum likelihood estimation is shown to be conveniently implemented in SAS Proc NLMIXED. The performance of the methods is compared through applications to daily drinking records in a secondary data analysis from a randomized controlled trial of topiramate for alcohol dependence treatment. We find that all three models provide a significantly better fit than the log-normal model, and there exists strong evidence for heteroscedasticity. We also compare the three models by the likelihood ratio tests for non-nested hypotheses (Vuong(3)). The results suggest that the generalized gamma distribution provides the best fit, though no statistically significant differences are found in pairwise model comparisons.

  18. Repeat colonoscopy after a colonoscopy with a negative result in Ontario: a population-based cohort study.

    Science.gov (United States)

    Hol, Lieke; Sutradhar, Rinku; Gu, Sumei; Baxter, Nancy N; Rabeneck, Linda; Tinmouth, Jill M; Paszat, Lawrence F

    2015-01-01

    Data suggest the overuse of repeat colonoscopies, especially in patients at low risk for colorectal cancer. Our objective was to evaluate the time to repeat colonoscopies in low-risk patients aged 50-79 years old and the associated patient- and endoscopist-related factors. All patients aged 50-79 years of age who underwent a complete outpatient colonoscopy with a negative result between 2000 and 2007 were identified from the Ontario Health Insurance Plan database. A colonoscopy performed within 5.5 years of follow-up after the index colonoscopy was considered an early repeat colonoscopy. Patient, endoscopist and endoscopy setting characteristics were recorded and their association with an early repeat colonoscopy was determined using an extended Cox proportional hazards regression model. The cohort consisted of 546 467 patients: 55.4% of the patients were female with a mean age of 61.1 years (95% confidence interval [CI] 61.1-61.2). The cumulative percentage of early repeat colonoscopy after 5.5 years was 33.7%. The rate decreased significantly between 2000 and 2007 (hazard ratio [HR] 0.35, 95% CI 0.34-0.36). General surgeons were associated with a higher risk of early repeat colonoscopy than gastroenterologists (HR 1.27, 95% CI 1.25-1.28). Endoscopists practising in a nonhospital setting were more likely to perform an early repeat colonoscopy (HR 1.26, 95% CI 1.22-1.30) than endoscopists at a hospital. This study showed that there was overuse of early repeat colonoscopy in more than 30% of patients who were at low risk for colorectal cancer. The risk decreased significantly between 2000 and 2007 but was still greater than 20% in 2007. Our findings can be used to develop targeted educational interventions among subgroups of endoscopists with a higher rate of early repeat colonoscopy.

  19. Assessing variability and comparing short-term biomarkers of styrene exposure using a repeated measurements approach.

    Science.gov (United States)

    Fustinoni, S; Manini, P; Campo, L; De Palma, G; Andreoli, R; Mutti, A; Bertazzi, P A; Rappaport, S M

    2010-01-15

    The aim of this work is to compare several short-term biomarkers of styrene exposure, namely urinary styrene (StyU), mercapturic acids (M1+M2), mandelic acid (MA), phenylglyoxylic acid (PGA), phenylglycine (PHG), and 4-vinylphenol conjugates (VP), for use as biomarkers of exposure in epidemiologic studies. A repeated measurements protocol (typically 4 measurements per worker over 6 weeks) was applied to measure airborne styrene (StyA) and urinary biomarkers in 10 varnish and 8 fiberglass reinforced plastic workers. Estimated geometric mean personal exposures to StyA were 2.96mg/m(3) in varnish workers and 15.7mg/m(3) in plastic workers. The corresponding levels of StyU, M1+M2, MA, PGA, MA+PGA, PHG and VP were 5.13microg/L, 0.111, 38.2, 22.7, 62.6, 0.978, and 3.97mg/g creatinine in varnish workers and 8.38microg/L, 0.303, 146, 83.4, 232, 2.85 and 3.97mg/g creatinine in plastic workers. Within-worker (sigma(wY)(2)) and between-worker (sigma(bY)(2)) variance components were estimated from the log-transformed data as were the corresponding fold ranges containing 95% of the respective lognormal distributions of daily levels ((w)R(0.95)) and subject-specific mean levels ((b)R(0.95)). Estimates of (w)R(0.95) (range: 4-26) were generally smaller than those of (b)R(0.95) (range: 5-790) for both environmental and biological markers; this indicates that exposures varied much more between workers than within workers in these groups. Since attenuation bias in an estimated exposure-response relationship increases with the variance ratio lambda=sigma(wY)(2)/sigma(bY)(2), we estimated values of lambda for all exposure measures in our study. Values of lambda were typically much less than one (median=0.220) and ranged from 0.089 for M1+M2 in plastic workers to 1.38 for PHG in varnish workers. Since values of lambda were 0.147 and 0.271 for StyA in varnish workers and plastic workers, respectively, compared to 0.178 and 0.210 for MA in the same groups, our results suggest that either

  20. Repeatability and Reproducibility of Compression Strength Measurements Conducted According to ASTM E9

    Science.gov (United States)

    Luecke, William E.; Ma, Li; Graham, Stephen M.; Adler, Matthew A.

    2010-01-01

    Ten commercial laboratories participated in an interlaboratory study to establish the repeatability and reproducibility of compression strength tests conducted according to ASTM International Standard Test Method E9. The test employed a cylindrical aluminum AA2024-T351 test specimen. Participants measured elastic modulus and 0.2 % offset yield strength, YS(0.2 % offset), using an extensometer attached to the specimen. The repeatability and reproducibility of the yield strength measurement, expressed as coefficient of variations were cv(sub r)= 0.011 and cv(sub R)= 0.020 The reproducibility of the test across the laboratories was among the best that has been reported for uniaxial tests. The reported data indicated that using diametrically opposed extensometers, instead of a single extensometer doubled the precision of the test method. Laboratories that did not lubricate the ends of the specimen measured yield stresses and elastic moduli that were smaller than those measured in laboratories that lubricated the specimen ends. A finite element analysis of the test specimen deformation for frictionless and perfect friction could not explain the discrepancy, however. The modulus measured from stress-strain data were reanalyzed using a technique that finds the optimal fit range, and applies several quality checks to the data. The error in modulus measurements from stress-strain curves generally increased as the fit range decreased to less than 40 % of the stress range.

  1. Accounting for uncertainty in volumes of seabed change measured with repeat multibeam sonar surveys

    Science.gov (United States)

    Schimel, Alexandre C. G.; Ierodiaconou, Daniel; Hulands, Lachlan; Kennedy, David M.

    2015-12-01

    Seafloors of unconsolidated sediment are highly dynamic features; eroding or accumulating under the action of tides, waves and currents. Assessing which areas of the seafloor experienced change and measuring the corresponding volumes involved provide insights into these important active sedimentation processes. Computing the difference between Digital Elevation Models (DEMs) obtained from repeat Multibeam Echosounders (MBES) surveys has become a common technique to identify these areas, but the uncertainty in these datasets considerably affects the estimation of the volumes displaced. The two main techniques used to take into account uncertainty in volume estimations are the limitation of calculations to areas experiencing a change in depth beyond a chosen threshold, and the computation of volumetric confidence intervals. However, these techniques are still in their infancy and, as a result, are often crude, seldom used or poorly understood. In this article, we explored a number of possible methodological advances to address this issue, including: (1) using the uncertainty information provided by the MBES data processing algorithm CUBE, (2) adapting fluvial geomorphology techniques for volume calculations using spatially variable thresholds and (3) volumetric histograms. The nearshore seabed off Warrnambool harbour - located in the highly energetic southwest Victorian coast, Australia - was used as a test site. Four consecutive MBES surveys were carried out over a four-months period. The difference between consecutive DEMs revealed an area near the beach experiencing large sediment transfers - mostly erosion - and an area of reef experiencing increasing deposition from the advance of a nearby sediment sheet. The volumes of sediment displaced in these two areas were calculated using the techniques described above, both traditionally and using the suggested improvements. We compared the results and discussed the applicability of the new methodological improvements

  2. Effect of repeated contact on adhesion measurements involving polydimethylsiloxane structural material

    Science.gov (United States)

    Kroner, E.; Maboudian, R.; Arzt, E.

    2009-09-01

    During the last few years several research groups have focused on the fabrication of artificial gecko inspired adhesives. For mimicking these structures, different polymers are used as structure material, such as polydimethylsiloxanes (PDMS), polyurethanes (PU), and polypropylene (PP). While these polymers can be structured easily and used for artificial adhesion systems, the effects of repeated adhesion testing have never been investigated closely. In this paper we report on the effect of repeated adhesion measurements on the commercially available poly(dimethylsiloxane) polymer kit Sylgard 184 (Dow Corning). We show that the adhesion force decreases as a function of contact cycles. The rate of change and the final value of adhesion are found to depend on the details of the PDMS synthesis and structuring.

  3. Effect of repeated contact on adhesion measurements involving polydimethylsiloxane structural material

    Energy Technology Data Exchange (ETDEWEB)

    Kroner, E; Arzt, E [INM-Leibniz Institute for New Materials, Campus D2 2, 66125 Saarbruecken (Germany); Maboudian, R, E-mail: elmar.kroner@inm-gmbh.de [Department of Chem. Eng., 201 Gilman Hall, University of California, Berkeley, CA 94720-1462 (United States)

    2009-09-15

    During the last few years several research groups have focused on the fabrication of artificial gecko inspired adhesives. For mimicking these structures, different polymers are used as structure material, such as polydimethylsiloxanes (PDMS), polyurethanes (PU), and polypropylene (PP). While these polymers can be structured easily and used for artificial adhesion systems, the effects of repeated adhesion testing have never been investigated closely. In this paper we report on the effect of repeated adhesion measurements on the commercially available poly(dimethylsiloxane) polymer kit Sylgard 184 (Dow Corning). We show that the adhesion force decreases as a function of contact cycles. The rate of change and the final value of adhesion are found to depend on the details of the PDMS synthesis and structuring.

  4. The results of Helicobacter pylori eradication on repeated bleeding in patients with stomach ulcer.

    Science.gov (United States)

    Horvat, Darko; Vcev, Aleksandar; Soldo, Ivan; Timarac, Jasna; Dmitrović, Branko; Misević, Tonci; Ivezić, Zdravko; Kraljik, Nikola

    2005-06-01

    The triple therapy of Helicobacter pylori eradication prevents repeated bleeding from stomach ulcer. The aim of this one-way blind prospective study was to evaluate the efficiency of the two-week triple therapy for Helicobacter pylori eradication in preventing renewed bleeding in patients with stomach ulcer within one year. This research included 60 hospitalized patients with bleeding stomach ulcer and positive Helicobacter pylori infection, 34 men and 26 women (average age 59.7 years). The patients were given therapeutic scheme of omeprazol--amoxicilin--metrodinazol (OAM) eradication for 14 days. Eradication of H. pylori infection was defined as lack of proof of the infection one month or several months after therapy suspension. By applying triple OAM therapy within two weeks the eradication was successful in 72%. In the group of 17 H. pylori positive patients there were 8 patients (47.6%) with repeated stomach ulcer and 3 patients (18%) with bleeding. Within the group of 43 H. pylori negative patients there were only 2 patients (4.65%) with repeated stomach ulcer and 1 patient (2%) with bleeding, during the observed period of 12 months. This research confirms the hypothesis about the necessity of eradication of Helicobacter pylori infection in patients with bleeding stomach ulcer as prevention of repeated bleeding.

  5. Validity and repeatability of a depth camera-based surface imaging system for thigh volume measurement.

    Science.gov (United States)

    Bullas, Alice M; Choppin, Simon; Heller, Ben; Wheat, Jon

    2016-10-01

    Complex anthropometrics such as area and volume, can identify changes in body size and shape that are not detectable with traditional anthropometrics of lengths, breadths, skinfolds and girths. However, taking these complex with manual techniques (tape measurement and water displacement) is often unsuitable. Three-dimensional (3D) surface imaging systems are quick and accurate alternatives to manual techniques but their use is restricted by cost, complexity and limited access. We have developed a novel low-cost, accessible and portable 3D surface imaging system based on consumer depth cameras. The aim of this study was to determine the validity and repeatability of the system in the measurement of thigh volume. The thigh volumes of 36 participants were measured with the depth camera system and a high precision commercially available 3D surface imaging system (3dMD). The depth camera system used within this study is highly repeatable (technical error of measurement (TEM) of <1.0% intra-calibration and ~2.0% inter-calibration) but systematically overestimates (~6%) thigh volume when compared to the 3dMD system. This suggests poor agreement yet a close relationship, which once corrected can yield a usable thigh volume measurement.

  6. An L-band SAR for repeat pass deformation measurements on a UAV platform

    Science.gov (United States)

    Hensley, Scott; Lou, Yunling; Rosen, Paul; Wheeler, Kevin; Zebker, Howard; Madsen, Soren; Miller, Tim; Hoffman, Jim; Farra, Don

    2003-01-01

    We are proposing to develop a miniaturized polarimetric L-band synthetic aperture radar (SAR) for repeat-pass differential interferometric measurements of deformation for rapidly deforming surfaces of geophysical interest such as volcanoes or earthquakes that is to be flown on a unmanned aerial vehicle (UAV) or minimally piloted vehicle (MPV). Upon surveying the capabilities and availabilities of such aircraft, the Proteus aircraft and the ALTAIR UAV appear to meet our criteria in terms of payload capabilities, flying altitude, and endurance. To support the repeat pass deformation capability it is necessary to control flight track capability of the aircraft to be within a specified 10 m tube with a goal of 1 m. This requires real-time GPS control of the autopilot to achieve these objectives that has not been demonstrated on these aircraft. Based on the Proteus and ALTAIR's altitude of 13.7 km (45,000 ft), we are designing a fully polarimetric L-band radar with 80 MHz bandwidth and a 16 km range swath. The radar will have an active electronic beam steering antenna to achieve a Doppler centroid stability that is necessary for repeat-pass interferometry. This paper presents some of the trade studies for the platform, instrument and the expected science.

  7. Accuracy and repeatability of direct ciliary sulcus diameter measurements by full-scale 50-megahertz ultrasound biomicroscopy

    Institute of Scientific and Technical Information of China (English)

    LI De-jiao; WANG Ning-li; CHEN Shu; LI Shu-ning; MU Da-peng; WANG Tao

    2009-01-01

    Background Phakic intraocular lens (pIOL) implantation has been a popular means for the treatment of high ametropia. Measurements of ciliary sulcus diameter is important for pIOL size determining. But till now, no perfect system can directly measure it. The present study was to evaluate the accuracy, repeatability and reproducibility of direct sulcus diameter measurements obtained by a full-scale 50-megahertz (MHz) ultrasound biomicroscopy (UBM).Methods A fresh cadaver human eye with a scale marker inserted through the posterior chamber plane from 3 o'clock to 9 o'clock meridian and 30 randomly selected eyes from 30 normal subjects were scanned by full-scale 50-MHz UBM in horizontal meridional scan plane. The distance between the scales and the whole length of the marker inside the cadaver eye were measured by the same observer using the "built-in" measurement tools and the indicating error of instrument was calculated. Reproducibility of the measurement was evaluated in 30 eyes by 2 operators using Blander and Altman plot test. Repeatability was evaluated from 10 successive eyes randomly selected from the 30 eyes by one operator.Results On a scale of 1 mm, the greatest indicating error was 40 μm; the mean largest indicating error of 1 mm scale from the 10 images was (26±14) μm; on a scale of 11 mm, the greatest indicating error was 70 μo; the error rate was 0.64%. The mean length of the needle inside the eye of the 10 images was 11.05 mm, with the mean indicating error of 47 μm, the average error rate was 0.43%. For ciliary sulcus diameter measurements in vivo, the coefficient of variation was 0.38%; the coefficients of repeatability for intra-observer and inter-observer measurements were 1.99% and 2.55%, respectively. The limits of agreement for intra-observer and inter-observer measurement were-0.41 mm to 0.48 mm and -0.59 mm to 0.58 ram, respectively.Conclusion The full-scale 50-MHz UBM can be a high accuracy and good repeatability means for direct

  8. Measurement of bedform migration rates on the Lower Missouri River in Missouri, USA using repeat measurements with a multibeam echosounder

    Science.gov (United States)

    Elliott, Caroline M.; Jacobson, Robert B.

    2016-01-01

    High-resolution repeat multibeam echosounder measurements on the Lower Missouri River near Boonville, Missouri, USA show bedform movement and sand storage patterns over daily to seasonal time scales and a range of discharges. Higher flows are frequently, but not always, associated with larger bedforms, higher bedform movement rates, and higher bedload transport rates. Measurements of the temporal and spatial variability in sand dune sizes, transport rates, and sand storage across the river channel have increased understanding of the dynamics of habitats utilized by benthic organisms over multiple life stages and daily to seasonal time scales.

  9. Specific Measurement of Tethered Running Kinetics and its Relationship to Repeated Sprint Ability

    Directory of Open Access Journals (Sweden)

    Sousa Filipe

    2015-12-01

    Full Text Available Repeated sprint ability has been widely studied by researchers, however, analysis of the relationship between most kinetic variables and the effect of fatigue is still an ongoing process. To search for the best biomechanical parameter to evaluate repeated sprint ability, several kinetic variables were measured in a tethered field running test and compared regarding their sensitivity to fatigue and correlation with time trials in a free running condition. Nine male sprint runners (best average times: 100 m = 10.45 ± 0.07 s; 200 m = 21.36 ± 0.17 s; 400 m = 47.35 ± 1.09 s completed two test sessions on a synthetic track. Each session consisted of six 35 m sprints interspersed by 10 s rest under tethered field running or free running conditions. Force, power, work, an impulse and a rate of force development were all directly measured using the sensors of a new tethered running apparatus, and a one-way ANOVA with Scheffé post-hoc test used to verify differences between sprints (p < 0.05. Pearson product-moment correlation measured the relationship between mechanical variables and free running performance. A total impulse, the rate of force development and maximum force did not show significant differences for most sprints. These three variables presented low to moderate correlations with free running performance (r between 0.01 and -0.35. Maximum and mean power presented the strongest correlations with free running performance (r = -0.71 and -0.76, respectively; p < 0.001, followed by mean force (r = -0.61; p < 0.001 and total work (r = -0.50; p < 0.001. It was concluded that under a severe work-to-rest ratio condition, power variables were better suited to evaluating repeated sprint ability than the other studied variables.

  10. Characterisation and measurement of signals generated by DVB-H 'GAP-filler' repeaters.

    Science.gov (United States)

    Baldini, M; Barellini, A; Bogi, L; Licitra, G; Silvi, A M; Zari, A

    2009-12-01

    DVB-H (Digital Video Broadcasting Handheld) is the standard developed by DVB Project and approved by ETSI with the aim of providing the reception of DVB signals even in mobility but also data transfers and multimedia services. The introduction and development of the DVB-H system is still ongoing. In this context, this work focuses on the temporal trend of electromagnetic impact of an urban DVB-H repeater (called 'gap-filler') for exposure assessment purposes; it also describes a method for its measurement by means of narrow band instrumental chains.

  11. Measuring the Activity of Leucine-Rich Repeat Kinase 2: A Kinase Involved in Parkinson's Disease

    Science.gov (United States)

    Lee, Byoung Dae; Li, Xiaojie; Dawson, Ted M.; Dawson, Valina L.

    2015-01-01

    Mutations in the LRRK2 (Leucine-Rich Repeat Kinase 2) gene are the most common cause of autosomal dominant Parkinson's disease. LRRK2 has multiple functional domains including a kinase domain. The kinase activity of LRRK2 is implicated in the pathogenesis of Parkinson's disease. Developing an assay to understand the mechanisms of LRRK2 kinase activity is important for the development of pharmacologic and therapeutic applications. Here, we describe how to measure in vitro LRRK2 kinase activity and its inhibition. PMID:21960214

  12. GSTM1 and APE1 genotypes affect arsenic-induced oxidative stress: a repeated measures study

    Directory of Open Access Journals (Sweden)

    Quamruzzaman Quazi

    2007-12-01

    Full Text Available Abstract Background Chronic arsenic exposure is associated with an increased risk of skin, bladder and lung cancers. Generation of oxidative stress may contribute to arsenic carcinogenesis. Methods To investigate the association between arsenic exposure and oxidative stress, urinary 8-hydroxy-2'-deoxyguanosine (8-OHdG was evaluated in a cohort of 97 women recruited from an arsenic-endemic region of Bangladesh in 2003. Arsenic exposure was measured in urine, toenails, and drinking water. Drinking water and urine samples were collected on three consecutive days. Susceptibility to oxidative stress was evaluated by genotyping relevant polymorphisms in glutathione-s transferase mu (GSTM1, human 8-oxoguanine glycosylase (hOGG1 and apurinic/apyrimidinic endonuclease (APE1 genes using the Taqman method. Data were analyzed using random effects Tobit regression to account for repeated measures and 8-OHdG values below the detection limit. Results A consistent negative effect for APE1 was observed across water, toenail and urinary arsenic models. APE1 148 glu/glu + asp/glu genotype was associated with a decrease in logged 8-OHdG of 0.40 (95%CI -0.73, -0.07 compared to APE1 148 asp/asp. An association between total urinary arsenic and 8-OHdG was observed among women with the GSTM1 null genotype but not in women with GSTM1 positive. Among women with GSTM1 null, a comparison of the second, third, and fourth quartiles of total urinary arsenic to the first quartile resulted in a 0.84 increase (95% CI 0.27, 1.42, a 0.98 increase (95% CI 033, 1.66 and a 0.85 increase (95% CI 0.27, 1.44 in logged 8-OHdG, respectively. No effects between 8-OHdG and toenail arsenic or drinking water arsenic were observed. Conclusion These results suggest the APE1 variant genotype decreases repair of 8-OHdG and that arsenic exposure is associated with oxidative stress in women who lack a functional GSTM1 detoxification enzyme.

  13. Repeatability and Accuracy of Exoplanet Eclipse Depths Measured with Post-Cryogenic Spitzer

    CERN Document Server

    Ingalls, James G; Carey, S J; Stauffer, John R; Lawrence, Patrick J; Grillmair, Carl J; Buzasi, Derek; Deming, Drake; Diamond-Lowe, Hannah; Evans, Thomas M; Morello, G; Stevenson, Kevin B; Wong, Ian; Capak, Peter; Glaccum, William; Laine, Seppo; Surace, Jason; Storrie-Lombardi, Lisa

    2016-01-01

    We examine the repeatability, reliability, and accuracy of differential exoplanet eclipse depth measurements made using the InfraRed Array Camera (IRAC) on the Spitzer Space Telescope during the post-cryogenic mission. We have re-analyzed an existing 4.5{\\mu}m dataset, consisting of 10 observations of the XO-3 b system during secondary eclipse, using 7 different techniques for removing correlated noise. We find that, on average, for a given technique the eclipse depth estimate is repeatable from epoch to epoch to within 150 parts per million (ppm). Most techniques derive eclipse depths that do not vary by more than a factor 2 of the photon noise limit. Nearly all methods accurately assess their own errors: for these methods the individual measurement uncertainties are comparable to the scatter in eclipse depths over the 10-epoch sample. To assess the accuracy of the techniques as well as clarify the difference between instrumental and other sources of measurement error, we have also analyzed a simulated datas...

  14. Measuring the Dynamic Soil Response During Repeated Wheeling Using Seismic Methods

    DEFF Research Database (Denmark)

    Keller, Thomas; Carizzon, Marco; Berisso, Feto Esimo

    2013-01-01

    Our understanding of soil deformation processes, especially its dynamics, remains limited. This hampers accurate predictions of the impact of soil management practices such as agricultural field traffic on (physical) soil functions. The main objective of this study was to investigate whether...... seismic measurements could be used to assess the dynamic soil behavior during repeated loading. Moreover, we aimed at linking the velocity of P-waves, Vp, to traditionally measured soil properties associated with soil compaction, namely bulk density (ρb) and penetrometer resistance. A wheeling experiment......, and simulated the evolution of bulk density due to the wheeling using a soil compaction model. The dynamic soil response during loading–unloading–reloading cycles could be well captured with the seismic method. The measured Vp related to bulk density, and the compaction-induced increase in Vp correlated...

  15. The use of a measure of acute irritation to predict the outcome of repeated usage of hand soap products.

    Science.gov (United States)

    Williams, C; Wilkinson, M; McShane, P; Pennington, D; Fernandez, C; Pierce, S

    2011-06-01

    Healthcare-associated infection is an important worldwide problem that could be reduced by better hand hygiene practice. However, an increasing number of healthcare workers are experiencing irritant contact dermatitis of the hands as a result of repeated hand washing. This may lead to a reduced level of compliance with regard to hand hygiene. To assess whether a measure of acute irritation by hand soaps could predict the effects of repeated usage over a 2-week period. In a double-blind, randomized comparison study, the comparative irritation potential of four different hand soaps was assessed over a 24-h treatment period. The effect of repeated hand washing with the hand soap products over a 2-week period in healthy adult volunteers on skin barrier function was then determined by assessment of transepidermal water loss (TEWL), epidermal hydration and a visual assessment using the Hand Eczema Severity Index (HECSI) at days 0, 7 and 14. A total of 121 subjects from the 123 recruited completed phase 1 of the study. All four products were seen to be significantly different from each other in terms of the irritant reaction observed and all products resulted in a significantly higher irritation compared with the no-treatment control. Seventy-nine of the initial 121 subjects were then enrolled into the repeated usage study. A statistically significant worsening of the clinical condition of the skin as measured by HECSI was seen from baseline to day 14 in those subjects repeatedly washing their hands with two of the four soap products (products C and D) with P-values of 0·02 and 0·01, respectively. Subclinical assessment of the skin barrier function by measuring epidermal hydration was significantly increased from baseline to day 7 after repeated hand washing with products A, B and D but overall no significant change was seen in all four products tested by day 14. A statistically significant increase in TEWL at day 14 was seen for product A (P = 0·02) indicating a

  16. Specific Measurement of Tethered Running Kinetics and its Relationship to Repeated Sprint Ability.

    Science.gov (United States)

    Sousa, Filipe; Dos Reis, Ivan; Ribeiro, Luiz; Martins, Luiz; Gobatto, Claudio

    2015-12-22

    Repeated sprint ability has been widely studied by researchers, however, analysis of the relationship between most kinetic variables and the effect of fatigue is still an ongoing process. To search for the best biomechanical parameter to evaluate repeated sprint ability, several kinetic variables were measured in a tethered field running test and compared regarding their sensitivity to fatigue and correlation with time trials in a free running condition. Nine male sprint runners (best average times: 100 m = 10.45 ± 0.07 s; 200 m = 21.36 ± 0.17 s; 400 m = 47.35 ± 1.09 s) completed two test sessions on a synthetic track. Each session consisted of six 35 m sprints interspersed by 10 s rest under tethered field running or free running conditions. Force, power, work, an impulse and a rate of force development were all directly measured using the sensors of a new tethered running apparatus, and a one-way ANOVA with Scheffé post-hoc test used to verify differences between sprints (p sprints. These three variables presented low to moderate correlations with free running performance (r between 0.01 and -0.35). Maximum and mean power presented the strongest correlations with free running performance (r = -0.71 and -0.76, respectively; p sprint ability than the other studied variables.

  17. On the Analysis of a Repeated Measure Design in Genome-Wide Association Analysis

    Directory of Open Access Journals (Sweden)

    Young Lee

    2014-11-01

    Full Text Available Longitudinal data enables detecting the effect of aging/time, and as a repeated measures design is statistically more efficient compared to cross-sectional data if the correlations between repeated measurements are not large. In particular, when genotyping cost is more expensive than phenotyping cost, the collection of longitudinal data can be an efficient strategy for genetic association analysis. However, in spite of these advantages, genome-wide association studies (GWAS with longitudinal data have rarely been analyzed taking this into account. In this report, we calculate the required sample size to achieve 80% power at the genome-wide significance level for both longitudinal and cross-sectional data, and compare their statistical efficiency. Furthermore, we analyzed the GWAS of eight phenotypes with three observations on each individual in the Korean Association Resource (KARE. A linear mixed model allowing for the correlations between observations for each individual was applied to analyze the longitudinal data, and linear regression was used to analyze the first observation on each individual as cross-sectional data. We found 12 novel genome-wide significant disease susceptibility loci that were then confirmed in the Health Examination cohort, as well as some significant interactions between age/sex and SNPs.

  18. Multiple-objective response-adaptive repeated measurement designs in clinical trials for binary responses.

    Science.gov (United States)

    Liang, Yuanyuan; Li, Yin; Wang, Jing; Carriere, Keumhee C

    2014-02-20

    A multiple-objective allocation strategy was recently proposed for constructing response-adaptive repeated measurement designs for continuous responses. We extend the allocation strategy to constructing response-adaptive repeated measurement designs for binary responses. The approach with binary responses is quite different from the continuous case, as the information matrix is a function of responses, and it involves nonlinear modeling. To deal with these problems, we first build the design on the basis of success probabilities. Then we illustrate how various models can accommodate carryover effects on the basis of logits of response profiles as well as any correlation structure. Through computer simulations, we find that the allocation strategy developed for continuous responses also works well for binary responses. As expected, design efficiency in terms of mean squared error drops sharply, as more emphasis is placed on increasing treatment benefit than estimation precision. However, we find that it can successfully allocate more patients to better treatment sequences without sacrificing much estimation precision.

  19. Role of Repeat Muscle Compartment Pressure Measurements in Chronic Exertional Compartment Syndrome of the Lower Leg.

    Science.gov (United States)

    van Zantvoort, Aniek P M; de Bruijn, Johan A; Winkes, Michiel B; Hoogeveen, Adwin R; Teijink, Joep A W; Scheltinga, Marc R

    2017-06-01

    The diagnostic gold standard for diagnosing chronic exertional compartment syndrome (CECS) is a dynamic intracompartmental pressure (ICP) measurement of the muscle. The potential role of a repeat ICP (re-ICP) measurement in patients with persistent lower leg symptoms after surgical decompression or with ongoing symptoms after an earlier normal ICP is unknown. To study whether re-ICP measurements in patients with persistent CECS-like symptoms of the lower leg may contribute to the diagnosis of CECS after both surgical decompression and a previously normal ICP measurement. Case series; Level of evidence, 4. Charts of patients who underwent re-ICP measurement of lower leg compartments (anterior [ant], deep posterior [dp], and/or lateral [lat] compartments) between 2001 and 2013 were retrospectively studied. CECS was diagnosed on the basis of generally accepted cutoff pressures for newly onset CECS (Pedowitz criteria: ICP at rest ≥15 mmHg, ≥30 mmHg after 1 minute, or ≥20 mmHg 5 minutes after a provocative test). Factors predicting recurrent CECS after surgery or after a previously normal ICP measurement were analyzed. A total of 1714 ICP measurements were taken in 1513 patients with suspected CECS over a 13-year observation period. In all, 201 (12%) tests were re-ICP measurements for persistent lower leg symptoms. Based on the proposed ICP cutoff values, CECS recurrence was diagnosed in 16 of 62 previously operated compartments (recurrence rate, 26%; 53 patients [64% female]; median age, 24 years; age range, 15-78 years). Recurrence rates were not different among the 3 lower leg CECS compartments (ant-CECS, 17%; dp-CECS, 33%; lat-CECS, 30%; χ(2) = 1.928, P = .381). Sex (χ(2) = 0.058, P = .810), age (U = 378, z = 1.840, P = .066), bilaterality (χ(2) = 0.019, P = .889), and prefasciotomy ICP did not predict recurrence. Re-ICP measurements evaluating 20 compartments with previously normal ICP measurements (15 patients [53% female]; mean age, 31 ± 10 years

  20. Repeated Closed Head Injury in Mice Results in Sustained Motor and Memory Deficits and Chronic Cellular Changes.

    Directory of Open Access Journals (Sweden)

    Amanda N Bolton Hall

    Full Text Available Millions of mild traumatic brain injuries (TBIs occur every year in the United States, with many people subject to multiple head injuries that can lead to chronic behavioral dysfunction. We previously reported that mild TBI induced using closed head injuries (CHI repeated at 24h intervals produced more acute neuron death and glial reactivity than a single CHI, and increasing the length of time between injuries to 48h reduced the cumulative acute effects of repeated CHI. To determine whether repeated CHI is associated with behavioral dysfunction or persistent cellular damage, mice receiving either five CHI at 24h intervals, five CHI at 48h intervals, or five sham injuries at 24h intervals were evaluated across a 10 week period after injury. Animals with repeated CHI exhibited motor coordination and memory deficits, but not gait abnormalities when compared to sham animals. At 10wks post-injury, no notable neuron loss or glial reactivity was observed in the cortex, hippocampus, or corpus callosum. Argyrophilic axons were found in the pyramidal tract of some injured animals, but neither silver stain accumulation nor inflammatory responses in the injury groups were statistically different from the sham group in this region. However, argyrophilic axons, microgliosis and astrogliosis were significantly increased within the optic tract of injured animals. Repeated mild CHI also resulted in microgliosis and a loss of neurofilament protein 200 in the optic nerve. Lengthening the inter-injury interval from 24h to 48h did not effectively reduce these behavioral or cellular responses. These results suggest that repeated mild CHI results in persistent behavioral dysfunction and chronic pathological changes within the visual system, neither of which was significantly attenuated by lengthening the inter-injury interval from 24h to 48h.

  1. Repeated Geophysical Surface Measurements to Estimate the Dynamics of Underground Coalfires

    Science.gov (United States)

    Wuttke, M. W.; Kessels, W.; Han, J.; Halisch, M.; Rüter, H.; Lindner, H.

    2009-04-01

    in a range between -130 and 176 nT. The maxima are most likely caused by the conversion of pyrite and markasit into maghemite, hematite and magnetite. Therefore the identified patches with high magnetic anomalies should have a direct connection to the burning coal in firezone 18. The firezone in Wuda has been visited now for five, that in Queergou for two times. All the discussed geophysical measurements together allow an integrated interpretation. Each result can be related to the combustion process with a particular likelihood for the vertical projection to the combustion centre. Probability calculations with chosen weight factors for each observation method are discussed. A so called fireindex deduced from the repeated measurements reveals the dynamics of the coal fire.

  2. Repeated exposure to heat stress results in a diaphragm phenotype that resists ventilator-induced diaphragm dysfunction.

    Science.gov (United States)

    Yoshihara, Toshinori; Ichinoseki-Sekine, Noriko; Kakigi, Ryo; Tsuzuki, Takamasa; Sugiura, Takao; Powers, Scott K; Naito, Hisashi

    2015-11-01

    Controlled mechanical ventilation (CMV) is a life-saving intervention for patients in respiratory failure. Unfortunately, prolonged mechanical ventilation (MV) results in diaphragmatic atrophy and contractile dysfunction, both of which are predicted to contribute to problems in weaning patients from the ventilator. Therefore, developing a strategy to protect the diaphragm against ventilator-induced weakness is important. We tested the hypothesis that repeated bouts of heat stress result in diaphragm resistance against CMV-induced atrophy and contractile dysfunction. Male Wistar rats were randomly divided into six experimental groups: 1) control; 2) single bout of whole body heat stress; 3) repeated bouts of whole body heat stress; 4) 12 h CMV; 5) single bout of whole body heat stress 24 h before CMV; and 6) repeated bouts of whole body heat stress 1, 3, and 5 days before 12 h of CMV. Our results revealed that repeated bouts of heat stress resulted in increased levels of heat shock protein 72 in the diaphragm and protection against both CMV-induced diaphragmatic atrophy and contractile dysfunction at submaximal stimulation frequencies. The specific mechanisms responsible for this protection remain unclear: this heat stress-induced protection against CMV-induced diaphragmatic atrophy and weakness may be partially due to reduced diaphragmatic oxidative stress, diminished activation of signal transducer/transcriptional activator-3, lower caspase-3 activation, and decreased autophagy in the diaphragm.

  3. Improving Target Repeatability Yields Broader Results in Component Fabrication and Overall Build

    Science.gov (United States)

    Klein, Sallee; Gamboa, Eliseo; Gillespie, Robb; Huntington, Channing; Krauland, Christine; Kuranz, Carolyn; di Stefano, Carlos; Susalla, Peter; Lairson, Bruce; Elsner, Fred; Keiter, Paul; Drake, R. Paul

    2012-10-01

    The University of Michigan has been fabricating targets for high energy density experiments since 2003. Our experiments study physics relevant to laboratory astrophysics. Machined acrylic structures serve as a backbone supporting all the components on our targets, as well as providing us with a method that eases our build. A most vital component to nearly every target we build, is shielding. Employing techniques to bend gold foils, enables complex geometries and eliminates seams that possibly allow unwanted emission in our diagnostics. Many of our experiments explore the dynamics of a radiative shock launched into xenon or argon gas. Polyimide (PI) tubing confines the gas and is transmissive to the diagnostic x-rays used to probe the experiment. Recent interest in the shock dynamics of non-axisymmetric shocks has lead to the development of PI tubes with non-circular cross sections. We present the techniques we use to produce repeatable targets as well as recent improvements in our techniques.

  4. Accuracy and repeatability of quantitative fluoroscopy for the measurement of sagittal plane translation and finite centre of rotation in the lumbar spine.

    Science.gov (United States)

    Breen, Alexander; Breen, Alan

    2016-07-01

    Quantitative fluoroscopy (QF) was developed to measure intervertebral mechanics in vivo and has been found to have high repeatability and accuracy for the measurement of intervertebral rotations. However, sagittal plane translation and finite centre of rotation (FCR) are potential measures of stability but have not yet been fully validated for current QF. This study investigated the repeatability and accuracy of QF for measuring these variables. Repeatability was assessed from L2-S1 in 20 human volunteers. Accuracy was investigated using 10 consecutive measurements from each of two pairs of linked and instrumented dry human vertebrae as reference; one which tilted without translation and one which translated without tilt. The results found intra- and inter-observer repeatability for translation to be 1.1mm or less (SEM) with fair to substantial reliability (ICC 0.533-0.998). Intra-observer repeatability of FCR location for inter-vertebral rotations of 5° and above ranged from 1.5mm to 1.8mm (SEM) with moderate to substantial reliability (ICC 0.626-0.988). Inter-observer repeatability for FCR ranged from 1.2mm to 5.7mm, also with moderate to substantial reliability (ICC 0.621-0.878). Reliability was substantial (ICC>0.81) for 10/16 measures for translation and 5/8 for FCR location. Accuracy for translation was 0.1mm (fixed centre) and 2.2mm (moveable centre), with an FCR error of 0.3mm(x) and 0.4mm(y) (fixed centre). This technology was found to have a high level of accuracy and with a few exceptions, moderate to substantial repeatability for the measurement of translation and FCR from fluoroscopic motion sequences.

  5. Impact of repeated measures and sample selection on genome-wide association studies of fasting glucose

    Science.gov (United States)

    Rasmussen-Torvik, Laura J.; Alonso, Alvaro; Li, Man; Kao, Wen; Köttgen, Anna; Yan, Yuer; Couper, David; Boerwinkle, Eric; Bielinski, Suzette J.; Pankow, James S.

    2010-01-01

    Although GWAS have been performed in longitudinal studies, most used only a single trait measure. GWAS of fasting glucose have generally included only normoglycemic individuals. We examined the impact of both repeated measures and sample selection on GWAS in ARIC, a study which obtained four longitudinal measures of fasting glucose and included both individuals with and without prevalent diabetes. The sample included Caucasians and the Affymetrix 6.0 chip was used for genotyping. Sample sizes for GWAS analyses ranged from 8372 (first study visit) to 5782 (average fasting glucose). Candidate SNP analyses with SNPs identified through fasting glucose or diabetes GWAS were conducted in 9133 individuals, including 761 with prevalent diabetes. For a constant sample size, smaller p-values were obtained for the average measure of fasting glucose compared to values at any single visit, and two additional significant GWAS signals were detected. For four candidate SNPs (rs780094, rs10830963, rs7903146, and rs4607517), the strength of association between genotype and glucose was significantly (p-interaction fasting glucose candidate SNPs (rs780094, rs10830963, rs560887, rs4607517, rs13266634) the association with measured fasting glucose was more significant in the smaller sample without prevalent diabetes than in the larger combined sample of those with and without diabetes. This analysis demonstrates the potential utility of averaging trait values in GWAS studies and explores the advantage of using only individuals without prevalent diabetes in GWAS of fasting glucose. PMID:20839289

  6. Demystifying Results-Based Performance Measurement.

    Science.gov (United States)

    Jorjani, Hamid

    Many evaluators are convinced that Results-based Performance Measurement (RBPM) is an effective tool to improve service delivery and cost effectiveness in both public and private sectors. Successful RBPM requires self-directed and cross-functional work teams and the supporting infrastructure to make it work. There are many misconceptions and…

  7. Androgen receptor gene CAG repeat polymorphism and risk of isolated hypospadias: results from a meta-analysis.

    Science.gov (United States)

    Huang, G; Shan, W; Zeng, L; Huang, L

    2015-03-06

    Studies investigating the association between the CAG repeat polymorphism and the risk of isolated hypospadias have reported conflicting results. The aim of this study was to quantitatively summarize the evidence for such a relationship. Two investigators independently searched the Medline, Embase, CNKI, and Wanfang databases. Weighted mean difference and 95% confidence intervals for the CAG repeat polymorphism and isolated hypospadias were calculated using a random-effects model. Subgroup analyses were performed by race, study design, sample for DNA extraction, and hypospadias classifications. This meta-analysis included 6 case-control studies, including 444 isolated hypospadias cases and 727 controls. The results showed that patients with isolated hypospadias had longer CAG repeats in their androgen receptor gene sequence (weighted mean difference = 1.36, 95% confidence interval = 0.60-2.13; P = 0.0005). Similarly, stratified analyses also detected significant associations in all subgroups, excluding the group with severe hypospadias (weighted mean difference = 0.35, 95% confidence interval = -0.42-1.12; P = 0.38). This meta-analysis indicated that longer CAG repeats were associated with the risk of isolated hypospadias, and that longer CAG polymorphisms may be related to the etiology of isolated hypospadias. Future studies based on Asian and African-American patients should be performed to re-evaluate this association.

  8. Repeated Microsphere Delivery for Serial Measurement of Regional Blood Perfusion in the Chronically Instrumented, Conscious Canine

    Science.gov (United States)

    Bartoli, Carlo R.; Okabe, Kazunori; Akiyama, Ichiro; Coull, Brent; Godleski, John J.

    2008-01-01

    INTRODUCTION For chronic, repeated hemodynamic studies in conscious dogs, we designed and tested a chronically instrumented canine, microsphere delivery model. The goals of this study were to investigate the accuracy of repeated estimations of blood perfusion using fluorescent-labeled microspheres and to develop and validate a chronic preparation that permits consecutive estimations in the same conscious animal over an extended protocol. METHODS Via thoracotomy, 9 dogs were instrumented with left atrial appendage and aortic vascular access catheters connected to subcutaneous vascular access ports (VAPs). Four animals received 7 serial injections of 1.6 million 15μm microspheres (total: 11.2 million), and five animals received 8 serial injections of 2.25 million microspheres (total: 18 million) over the course of 11 or 18 weeks. RESULTS All catheters have remained bidirectionally patent during protocol for 14.9±0.8 (Mean±SEM) weeks. Sphere accumulation did not significantly alter global myocardial (p=0.69, p=0.25), renal (p=0.92, p=0.12), hepatic (p=0.84, p=0.32), or splenic (p=0.33, p=0.70) blood perfusion in either set of animals. CONCLUSIONS Catheters remained bidirectionally patent for months, did not interfere with the hemodynamic responses of the preparation, and allowed repeat percutaneous injection of microspheres and withdrawal of reference arterial blood from within conscious canines. Eight serial injections totaling 18 million microspheres over 18 weeks did not alter regional myocardial, hepatic, renal, or splenic blood flow. This dependable, chronic, percutaneous arterial access preparation provides a means for examining acute and long-term effects of pathophysiological, pharmaceutical, and environmental influences on regional arterial blood perfusion in conscious, large animals. PMID:17632127

  9. Estimation of the concordance correlation coefficient for repeated measures using SAS and R.

    Science.gov (United States)

    Carrasco, Josep L; Phillips, Brenda R; Puig-Martinez, Josep; King, Tonya S; Chinchilli, Vernon M

    2013-03-01

    The concordance correlation coefficient is one of the most common approaches used to assess agreement among different observers or instruments when the outcome of interest is a continuous variable. A SAS macro and R package are provided here to estimate the concordance correlation coefficient (CCC) where the design of the data involves repeated measurements by subject and observer. The CCC is estimated using U-statistics (UST) and variance components (VC) approaches. Confidence intervals and standard errors are reported along with the point estimate of the CCC. In the case of the VC approach, the linear mixed model output and variance components estimates are also provided. The performance of each function is shown by means of some examples with real data sets.

  10. Bayesian latent variable models for hierarchical clustered count outcomes with repeated measures in microbiome studies.

    Science.gov (United States)

    Xu, Lizhen; Paterson, Andrew D; Xu, Wei

    2017-04-01

    Motivated by the multivariate nature of microbiome data with hierarchical taxonomic clusters, counts that are often skewed and zero inflated, and repeated measures, we propose a Bayesian latent variable methodology to jointly model multiple operational taxonomic units within a single taxonomic cluster. This novel method can incorporate both negative binomial and zero-inflated negative binomial responses, and can account for serial and familial correlations. We develop a Markov chain Monte Carlo algorithm that is built on a data augmentation scheme using Pólya-Gamma random variables. Hierarchical centering and parameter expansion techniques are also used to improve the convergence of the Markov chain. We evaluate the performance of our proposed method through extensive simulations. We also apply our method to a human microbiome study.

  11. Causal inference in longitudinal comparative effectiveness studies with repeated measures of a continuous intermediate variable.

    Science.gov (United States)

    Wang, Chen-Pin; Jo, Booil; Brown, C Hendricks

    2014-09-10

    We propose a principal stratification approach to assess causal effects in nonrandomized longitudinal comparative effectiveness studies with a binary endpoint outcome and repeated measures of a continuous intermediate variable. Our method is an extension of the principal stratification approach originally proposed for the longitudinal randomized study "Prevention of Suicide in Primary Care Elderly: Collaborative Trial" to assess the treatment effect on the continuous Hamilton depression score adjusting for the heterogeneity of repeatedly measured binary compliance status. Our motivation for this work comes from a comparison of the effect of two glucose-lowering medications on a clinical cohort of patients with type 2 diabetes. Here, we consider a causal inference problem assessing how well the two medications work relative to one another on two binary endpoint outcomes: cardiovascular disease-related hospitalization and all-cause mortality. Clinically, these glucose-lowering medications can have differential effects on the intermediate outcome, glucose level over time. Ultimately, we want to compare medication effects on the endpoint outcomes among individuals in the same glucose trajectory stratum while accounting for the heterogeneity in baseline covariates (i.e., to obtain 'principal effects' on the endpoint outcomes). The proposed method involves a three-step model estimation procedure. Step 1 identifies principal strata associated with the intermediate variable using hybrid growth mixture modeling analyses. Step 2 obtains the stratum membership using the pseudoclass technique and derives propensity scores for treatment assignment. Step 3 obtains the stratum-specific treatment effect on the endpoint outcome weighted by inverse propensity probabilities derived from Step 2.

  12. Repeated exposure to severely limited sleep results in distinctive and persistent physiological imbalances in rats.

    Science.gov (United States)

    Everson, Carol A; Szabo, Aniko

    2011-01-01

    Chronic sleep disruption in laboratory rats leads to increased energy expenditure, connective tissue abnormalities, and increased weights of major organs relative to body weight. Here we report on expanded findings and the extent to which abnormalities become long-lasting, potentially permanent changes to health status after apparent recuperation from chronic sleep disruption. Rats were exposed 6 times to long periods of disrupted sleep or control conditions during 10 weeks to produce adaptations and then were permitted nearly 4 months of undisturbed sleep. Measurements were made in tissues from these groups and in preserved tissue from the experimental and control groups of an antecedent study that lacked a lengthy recuperation period. Cycles of sleep restriction resulted in energy deficiency marked by a progressive course of hyperphagia and major (15%) weight loss. Analyses of tissue composition in chronically sleep-restricted rats indicated that protein and lipid amounts in internal organs were largely spared, while adipose tissue depots appeared depleted. This suggests high metabolic demands may have preserved the size of the vital organs relative to expectations of severe energy deficiency alone. Low plasma corticosterone and leptin concentrations appear to reflect low substrate availability and diminished adiposity. After nearly 4 months of recuperation, sleep-restricted rats were consuming 20% more food and 35% more water than did comparison control rats, despite normalized weight, normalized adipocytes, and elevated plasma leptin concentrations. Plasma cholesterol levels in recuperated sleep-restricted rats were diminished relative to those of controls. The chronically increased intake of nutriments and water, along with altered negative feedback regulation and substrate use, indicate that internal processes are modified long after a severe period of prolonged and insufficient sleep has ended.

  13. Repeated exposure to severely limited sleep results in distinctive and persistent physiological imbalances in rats.

    Directory of Open Access Journals (Sweden)

    Carol A Everson

    Full Text Available Chronic sleep disruption in laboratory rats leads to increased energy expenditure, connective tissue abnormalities, and increased weights of major organs relative to body weight. Here we report on expanded findings and the extent to which abnormalities become long-lasting, potentially permanent changes to health status after apparent recuperation from chronic sleep disruption. Rats were exposed 6 times to long periods of disrupted sleep or control conditions during 10 weeks to produce adaptations and then were permitted nearly 4 months of undisturbed sleep. Measurements were made in tissues from these groups and in preserved tissue from the experimental and control groups of an antecedent study that lacked a lengthy recuperation period. Cycles of sleep restriction resulted in energy deficiency marked by a progressive course of hyperphagia and major (15% weight loss. Analyses of tissue composition in chronically sleep-restricted rats indicated that protein and lipid amounts in internal organs were largely spared, while adipose tissue depots appeared depleted. This suggests high metabolic demands may have preserved the size of the vital organs relative to expectations of severe energy deficiency alone. Low plasma corticosterone and leptin concentrations appear to reflect low substrate availability and diminished adiposity. After nearly 4 months of recuperation, sleep-restricted rats were consuming 20% more food and 35% more water than did comparison control rats, despite normalized weight, normalized adipocytes, and elevated plasma leptin concentrations. Plasma cholesterol levels in recuperated sleep-restricted rats were diminished relative to those of controls. The chronically increased intake of nutriments and water, along with altered negative feedback regulation and substrate use, indicate that internal processes are modified long after a severe period of prolonged and insufficient sleep has ended.

  14. How integrated are behavioral and endocrine stress response traits? A repeated measures approach to testing the stress-coping style model.

    Science.gov (United States)

    Boulton, Kay; Couto, Elsa; Grimmer, Andrew J; Earley, Ryan L; Canario, Adelino V M; Wilson, Alastair J; Walling, Craig A

    2015-02-01

    It is widely expected that physiological and behavioral stress responses will be integrated within divergent stress-coping styles (SCS) and that these may represent opposite ends of a continuously varying reactive-proactive axis. If such a model is valid, then stress response traits should be repeatable and physiological and behavioral responses should also change in an integrated manner along a major axis of among-individual variation. While there is some evidence of association between endocrine and behavioral stress response traits, few studies incorporate repeated observations of both. To test this model, we use a multivariate, repeated measures approach in a captive-bred population of Xiphophorus birchmanni. We quantify among-individual variation in behavioral stress response to an open field trial (OFT) with simulated predator attack (SPA) and measure waterborne steroid hormone levels (cortisol, 11-ketotestosterone) before and after exposure. Under the mild stress stimulus (OFT), (multivariate) behavioral variation among individuals was consistent with a strong axis of personality (shy-bold) or coping style (reactive-proactive) variation. However, behavioral responses to a moderate stressor (SPA) were less repeatable, and robust statistical support for repeatable endocrine state over the full sampling period was limited to 11-ketotestosterone. Although post hoc analysis suggested cortisol expression was repeatable over short time periods, qualitative relationships between behavior and glucocorticoid levels were counter to our a priori expectations. Thus, while our results clearly show among-individual differences in behavioral and endocrine traits associated with stress response, the correlation structure between these is not consistent with a simple proactive-reactive axis of integrated stress-coping style. Additionally, the low repeatability of cortisol suggests caution is warranted if single observations (or indeed repeat measures over short sampling

  15. Microcomputer-based tests for repeated-measures: Metric properties and predictive validities

    Science.gov (United States)

    Kennedy, Robert S.; Baltzley, Dennis R.; Dunlap, William P.; Wilkes, Robert L.; Kuntz, Lois-Ann

    1989-01-01

    A menu of psychomotor and mental acuity tests were refined. Field applications of such a battery are, for example, a study of the effects of toxic agents or exotic environments on performance readiness, or the determination of fitness for duty. The key requirement of these tasks is that they be suitable for repeated-measures applications, and so questions of stability and reliability are a continuing, central focus of this work. After the initial (practice) session, seven replications of 14 microcomputer-based performance tests (32 measures) were completed by 37 subjects. Each test in the battery had previously been shown to stabilize in less than five 90-second administrations and to possess retest reliabilities greater than r = 0.707 for three minutes of testing. However, all the tests had never been administered together as a battery and they had never been self-administered. In order to provide predictive validity for intelligence measurement, the Wechsler Adult Intelligence Scale-Revised and the Wonderlic Personnel Test were obtained on the same subjects.

  16. Short term soil erosion dynamics in alpine grasslands - Results from a Fallout Radionuclide repeated-sampling approach

    Science.gov (United States)

    Arata, Laura; Meusburger, Katrin; Zehringer, Markus; Ketterer, Michael E.; Mabit, Lionel; Alewell, Christine

    2016-04-01

    Improper land management and climate change has resulted in accelerated soil erosion rates in Alpine grasslands. To efficiently mitigate and control soil erosion and reduce its environmental impact in Alpine grasslands, reliable and validated methods for comprehensive data generation on its magnitude and spatial extent are mandatory. The use of conventional techniques (e.g. sediment traps, erosion pins or rainfall simulations) may be hindered by the extreme topographic and climatic conditions of the Alps. However, the application of the Fallout Radionuclides (FRNs) as soil tracers has already showed promising results in these specific agro-ecosystems. Once deposited on the ground, FRNs strongly bind to fine particles at the surface soil and move across the landscape primarily through physical processes. As such, they provide an effective track of soil and sediment redistribution. So far, applications of FRN in the Alps include 137Cs (half-life: 30.2 years) and 239+240Pu (239Pu [half-life = 24110 years] and 240Pu [half-life = 6561 years]). To investigate short term (4-5 years) erosion dynamics in the Swiss Alps, the authors applied a FRNs repeated sampling approach. Two study areas in the central Swiss Alps have been investigated: the Urseren Valley (Canton Uri), where significant land use changes occurred in the last centuries, and the Piora Valley (Canton Ticino), where land use change plays a minor role. Soil samples have been collected at potentially erosive sites along the valleys over a period of 4-5 years and measured for 137Cs and 239+240Pu activity. The inventory change between the sampling years indicates high erosion and deposition dynamics at both valleys. High spatial variability of 137Cs activities at all sites has been observed, reflecting the heterogeneous distribution of 137Cs fallout after the Chernobyl power plant accident in 1986. Finally, a new modelling technique to convert the inventory changes to quantitative estimates of soil erosion has

  17. Status of a UAVSAR designed for repeat pass interferometry for deformation measurements

    Science.gov (United States)

    Hensley, Scott; Wheeler, Kevin; Sadowy, Greg; Miller, Tim; Shaffer, Scott; Muellerschoen, Ron; Jones, Cathleen; Zebker, Howard; Madsen, Soren; Paul, Rose

    2005-01-01

    NASA's Jet Propulsion Laboratory is currently implementing a reconfigurable polarimetric L-band synthetic aperture radar (SAR), specifically designed to acquire airborne repeat track interferometric (RTI) SAR data, also known as differential interferometric measurements. Differential interferometry can provide key deformation measurements, important for the scientific studies of Earthquakes and volcanoes. Using precision real-time GPS and a sensor controlled flight management system, the system will be able to fly predefined paths with great precision. The expected performance of the flight control system will constrain the flight path to be within a 10 m diameter tube about the desired flight track. The radar wilI be designed to operate on a UAV (Unpiloted Aria1 Vehicle) but will initially be demonstrated on a minimally piloted vehicle (MPV), such as the Proteus buitt by Scaled Composites or on a NASA Gulfstream III. The radar design is a fully polarimetric with an 80 MHz bandwidth (2 m range resolution) and 16 km range swath. The antenna is an electronically steered along track to assure that the actual antenna pointing can be controlled independent of the wind direction and speed. Other features supported by the antenna include an elevation monopulse option and a pulse-to-pulse resteering capability that will enable some novel modes of operation. The system will nominally operate at 45,000 ft (13800 m). The program began out as an Instrument Incubator Project (IIP) funded by NASA Earth Science and Technology Office (ESTO).

  18. Repeated Blood Pressure Measurements in Childhood in Prediction of Hypertension in Adulthood.

    Science.gov (United States)

    Oikonen, Mervi; Nuotio, Joel; Magnussen, Costan G; Viikari, Jorma S A; Taittonen, Leena; Laitinen, Tomi; Hutri-Kähönen, Nina; Jokinen, Eero; Jula, Antti; Cheung, Michael; Sabin, Matthew A; Daniels, Stephen R; Raitakari, Olli T; Juonala, Markus

    2016-01-01

    Hypertension may be predicted from childhood risk factors. Repeated observations of abnormal blood pressure in childhood may enhance prediction of hypertension and subclinical atherosclerosis in adulthood compared with a single observation. Participants (1927, 54% women) from the Cardiovascular Risk in Young Finns Study had systolic and diastolic blood pressure measurements performed when aged 3 to 24 years. Childhood/youth abnormal blood pressure was defined as above 90th or 95th percentile. After a 21- to 31-year follow-up, at the age of 30 to 45 years, hypertension (>140/90 mm Hg or antihypertensive medication) prevalence was found to be 19%. Carotid intima-media thickness was examined, and high-risk intima-media was defined as intima-media thickness >90th percentile or carotid plaques. Prediction of adulthood hypertension and high-risk intima-media was compared between one observation of abnormal blood pressure in childhood/youth and multiple observations by improved Pearson correlation coefficients and area under the receiver operating curve. When compared with a single measurement, 2 childhood/youth observations improved the correlation for adult systolic (r=0.44 versus 0.35, Ppressure. In addition, 2 abnormal childhood/youth blood pressure observations increased the prediction of hypertension in adulthood (0.63 for 2 versus 0.60 for 1 observation, P=0.003). When compared with 2 measurements, third observation did not provide any significant improvement for correlation or prediction (P always >0.05). A higher number of childhood/youth observations of abnormal blood pressure did not enhance prediction of adult high-risk intima-media thickness. Compared with a single measurement, the prediction of adult hypertension was enhanced by 2 observations of abnormal blood pressure in childhood/youth. © 2015 American Heart Association, Inc.

  19. Measurement of repeat effects in Chicago’s criminal social network

    Directory of Open Access Journals (Sweden)

    Paul Kump

    2016-07-01

    Full Text Available The “near-repeat” effect is a well-known criminological phenomenon in which the occurrence of a crime incident gives rise to a temporary elevation of crime risk within close physical proximity to an initial incident. Adopting a social network perspective, we instead define a near repeat in terms of geodesic distance within a criminal social network, rather than spatial distance. Specifically, we report a statistical analysis of repeat effects in arrest data for Chicago during the years 2003–2012. We divide the arrest data into two sets (violent crimes and other crimes and, for each set, we compare the distributions of time intervals between repeat incidents to theoretical distributions in which repeat incidents occur only by chance. We first consider the case of the same arrestee participating in repeat incidents (“exact repeats” and then extend the analysis to evaluate repeat risks of those arrestees near one another in the social network. We observe repeat effects that diminish as a function of geodesic distance and time interval, and we estimate typical time scales for repeat crimes in Chicago.

  20. Constructing Measure by Repeated Infinite Subdivision%通过反复无限细分定义测度

    Institute of Scientific and Technical Information of China (English)

    严质彬

    2005-01-01

    This paper generalizes the method of constructing measure by repeated finite subdivision in fTactal geometry to that by infinite subdivision. Two conditions for the existing method are removed. A measure on the interval [0, 1] is constructed using this generalized method.

  1. Cardiometabolic treatment decisions in patients with type 2 diabetes : the role of repeated measurements and medication burden

    NARCIS (Netherlands)

    Voorham, J.; Haaijer-Ruskamp, F. M.; Wolffenbuttel, B. H. R.; Stolk, R. P.; Denig, P.

    2010-01-01

    Purpose Clinical guidelines for cardiometabolic risk management indicate a simple threshold-based strategy for treatment, but physicians and their patients may be reluctant to modify drug treatment after a single elevated measurement. We determined how repeated measurements of blood pressure, choles

  2. Cardiometabolic treatment decisions in patients with type 2 diabetes : the role of repeated measurements and medication burden

    NARCIS (Netherlands)

    Voorham, J.; Haaijer-Ruskamp, F. M.; Wolffenbuttel, B. H. R.; Stolk, R. P.; Denig, P.

    2010-01-01

    Purpose Clinical guidelines for cardiometabolic risk management indicate a simple threshold-based strategy for treatment, but physicians and their patients may be reluctant to modify drug treatment after a single elevated measurement. We determined how repeated measurements of blood pressure,

  3. Tracking photon jumps with repeated quantum non-demolition parity measurements.

    Science.gov (United States)

    Sun, L; Petrenko, A; Leghtas, Z; Vlastakis, B; Kirchmair, G; Sliwa, K M; Narla, A; Hatridge, M; Shankar, S; Blumoff, J; Frunzio, L; Mirrahimi, M; Devoret, M H; Schoelkopf, R J

    2014-07-24

    Quantum error correction is required for a practical quantum computer because of the fragile nature of quantum information. In quantum error correction, information is redundantly stored in a large quantum state space and one or more observables must be monitored to reveal the occurrence of an error, without disturbing the information encoded in an unknown quantum state. Such observables, typically multi-quantum-bit parities, must correspond to a special symmetry property inherent in the encoding scheme. Measurements of these observables, or error syndromes, must also be performed in a quantum non-demolition way (projecting without further perturbing the state) and more quickly than errors occur. Previously, quantum non-demolition measurements of quantum jumps between states of well-defined energy have been performed in systems such as trapped ions, electrons, cavity quantum electrodynamics, nitrogen-vacancy centres and superconducting quantum bits. So far, however, no fast and repeated monitoring of an error syndrome has been achieved. Here we track the quantum jumps of a possible error syndrome, namely the photon number parity of a microwave cavity, by mapping this property onto an ancilla quantum bit, whose only role is to facilitate quantum state manipulation and measurement. This quantity is just the error syndrome required in a recently proposed scheme for a hardware-efficient protected quantum memory using Schrödinger cat states (quantum superpositions of different coherent states of light) in a harmonic oscillator. We demonstrate the projective nature of this measurement onto a region of state space with well-defined parity by observing the collapse of a coherent state onto even or odd cat states. The measurement is fast compared with the cavity lifetime, has a high single-shot fidelity and has a 99.8 per cent probability per single measurement of leaving the parity unchanged. In combination with the deterministic encoding of quantum information in cat

  4. Effects of CAG repeat length, HTT protein length and protein context on cerebral metabolism measured using magnetic resonance spectroscopy in transgenic mouse models of Huntington's disease.

    Science.gov (United States)

    Jenkins, Bruce G; Andreassen, Ole A; Dedeoglu, Alpaslan; Leavitt, Blair; Hayden, Michael; Borchelt, David; Ross, Christopher A; Ferrante, Robert J; Beal, M Flint

    2005-10-01

    Huntington's disease is a neurodegenerative illness caused by expansion of CAG repeats at the N-terminal end of the protein huntingtin. We examined longitudinal changes in brain metabolite levels using in vivo magnetic resonance spectroscopy in five different mouse models. There was a large (>50%) exponential decrease in N-acetyl aspartate (NAA) with time in both striatum and cortex in mice with 150 CAG repeats (R6/2 strain). There was a linear decrease restricted to striatum in N171-82Q mice with 82 CAG repeats. Both the exponential and linear decreases of NAA were paralleled in time by decreases in neuronal area measured histologically. Yeast artificial chromosome transgenic mice with 72 CAG repeats, but low expression levels, had less striatal NAA loss than the N171-82Q mice (15% vs. 43%). We evaluated the effect of gene context in mice with an approximate 146 CAG repeat on the hypoxanthine phosphoribosyltransferase gene (HPRT). HPRT mice developed an obese phenotype in contrast to weight loss in the R6/2 and N171-82Q mice. These mice showed a small striatal NAA loss (21%), and a possible increase in brain lipids detectable by magnetic resonance (MR) spectroscopy and decreased brain water T1. Our results indicate profound metabolic defects that are strongly affected by CAG repeat length, as well as gene expression levels and protein context.

  5. Preliminary evaluation of a micro-based repeated measures testing system

    Science.gov (United States)

    Kennedy, Robert S.; Wilkes, Robert L.; Lane, Norman E.

    1985-01-01

    A need exists for an automated performance test system to study the effects of various treatments which are of interest to the aerospace medical community, i.e., the effects of drugs and environmental stress. The ethics and pragmatics of such assessment demand that repeated measures in small groups of subjects be the customary research paradigm. Test stability, reliability-efficiency and factor structure take on extreme significance; in a program of study by the U.S. Navy, 80 percent of 150 tests failed to meet minimum metric requirements. The best is being programmed on a portable microprocessor and administered along with tests in their original formats in order to examine their metric properties in the computerized mode. Twenty subjects have been tested over four replications on a 6.0 minute computerized battery (six tests) and which compared with five paper and pencil marker tests. All tests achieved stability within the four test sessions, reliability-efficiencies were high (r greater than .707 for three minutes testing), and the computerized tests were largely comparable to the paper and pencil version from which they were derived. This computerized performance test system is portable, inexpensive and rugged.

  6. Tectonomagnetic study in the seismoactive area of Narmada–Son lineament, central India: Preliminary results on repeat field observations

    Indian Academy of Sciences (India)

    S Y Waghmare; S D Pimprikar; P B Gawali; L Carlo; A G Patil

    2009-06-01

    Repeated measurements of the total geomagnetic field on the five profiles have revealed a picture of stress-induced tectonomagnetic effect in the form of secular variation of the total geomagnetic field in the tectonically and seismically active area of Jabalpur and adjoining areas of the Narmada-Son lineament (NSL),central India.For this experiment,a reference base station was established within the study area at Jabalpur.Using proton precession magnetometers with a sensitivity of 0.1 nT, simultaneous measurements of total geomagnetic field were made annually at the base and all field stations.Five cycles of repeated observations have been performed between 2003 and 2007.For data analysis,a difference method has been applied and the residuals have been calculated as secular variations of the total geomagnetic field with values ranging from ± 0.1nT to about > ± 14.6nT/yr over the different stations.The anomalies in secular variation of the total geomagnetic field may be related to anomalous accumulation of tectonic stresses and tensions on the deep fault zones and crustal blocks due to recent geodynamic processes and active geological inhomogeneities in the NSL.

  7. Hepatic 18F-FDG Uptake Measurements on PET/MR: Impact of Volume of Interest Location on Repeatability

    Directory of Open Access Journals (Sweden)

    Liran Domachevsky

    2017-01-01

    Full Text Available Background. To investigate same day 18F-FDG (Fluorodeoxyglucose PET (Positron Emission Tomography/MR (Magnetic Resonance test-retest repeatability of Standardized Uptake Value measurements normalized for body weight (SUV and lean body mass (SUL in different locations in the liver. Methods. This prospective study was IRB approved with written informed consent obtained. 35 patients (20 women and 15 men, 61±11.2 years that performed a whole-body 18F-FDG PET/MR followed by liver-dedicated contrast-enhanced 18F-FDG PET/MR were included. SUV/L max, mean, and peak were measured inferior to, superior to, and at the right portal vein and in the left lobe of the liver. The coefficient of variation (CV and intraclass correlation coefficient (ICC were calculated and Bland-Altman plots were obtained. Results. The variability for SUV/L’s measurements was lowest inferior to the portal vein (<9.2% followed by measurements performed at the level of the portal vein (<14.6%. Conclusion. The area inferior to the portal vein is the most reliable location for hepatic 18F-FDG uptake measurements on PET/MR.

  8. A repeated measures experiment of green exercise to improve self-esteem in UK school children.

    Directory of Open Access Journals (Sweden)

    Katharine Reed

    Full Text Available Exercising in natural, green environments creates greater improvements in adult's self-esteem than exercise undertaken in urban or indoor settings. No comparable data are available for children. The aim of this study was to determine whether so called 'green exercise' affected changes in self-esteem; enjoyment and perceived exertion in children differently to urban exercise. We assessed cardiorespiratory fitness (20 m shuttle-run and self-reported physical activity (PAQ-A in 11 and 12 year olds (n = 75. Each pupil completed two 1.5 mile timed runs, one in an urban and another in a rural environment. Trials were completed one week apart during scheduled physical education lessons allocated using a repeated measures design. Self-esteem was measured before and after each trial, ratings of perceived exertion (RPE and enjoyment were assessed after completing each trial. We found a significant main effect (F (1,74, = 12.2, p<0.001, for the increase in self-esteem following exercise but there was no condition by exercise interaction (F (1,74, = 0.13, p = 0.72. There were no significant differences in perceived exertion or enjoyment between conditions. There was a negative correlation (r = -0.26, p = 0.04 between habitual physical activity and RPE during the control condition, which was not evident in the green exercise condition (r = -0.07, p = 0.55. Contrary to previous studies in adults, green exercise did not produce significantly greater increases in self-esteem than the urban exercise condition. Green exercise was enjoyed more equally by children with differing levels of habitual physical activity and has the potential to engage less active children in exercise.

  9. A novel AX+/BX- paradigm to assess fear learning and safety-signal processing with repeated-measure designs.

    Science.gov (United States)

    Kazama, Andy M; Schauder, Kimberly B; McKinnon, Michael; Bachevalier, Jocelyne; Davis, Michael

    2013-04-15

    One of the core symptoms of anxiety disorders, such as post-traumatic stress disorder, is the failure to overcome feelings of danger despite being in a safe environment. This deficit likely stems from an inability to fully process safety signals, which are cues in the environment that enable healthy individuals to over-ride fear in aversive situations. Studies examining safety signal learning in rodents, humans, and non-human primates currently rely on between-groups designs. Because repeated-measure designs reduce the number of subjects required, and facilitate a broader range of safety signal studies, the current project sought to develop a repeated-measures safety-signal learning paradigm in non-human primates. Twelve healthy rhesus macaques of both sexes received three rounds of auditory fear-potentiated startle training and testing using an AX+/BX- design with all visual cues. Cue AX was paired with an aversive blast of air, whereas the same X cue in compound with another B cue (BX) signaled the absence of an air blast. Hence, cue B served as a safety signal. Once animals consistently discriminated between the aversive (AX+) and safe (BX-) cues, measured by greater startle amplitude in the presence of AX vs. BX, they were tested for conditioned inhibition by eliciting startle in the presence of a novel ambiguous combined cue (AB). Similar to previous AX+/BX- studies, healthy animals rapidly learned to discriminate between the AX+ and BX- cues as well as demonstrate conditioned inhibition in the presence of the combined AB cue (i.e. lower startle amplitude in the presence of AB vs. AX). Additionally, animals performed consistently across three rounds of testing using three new cues each time. The results validate this novel method that will serve as a useful tool for better understanding the mechanisms for the regulation of fear and anxiety. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. [Postoperative sciatica from epidural fibrosis and lumbar arachnoiditis. Results of 38 repeat operations].

    Science.gov (United States)

    Benoist, M; Ficat, C; Baraf, P; Massare, C; Bard, M; Sarre, J; Cauchoix, J

    1979-11-01

    Lumbar epiduro-arachnoiditis is a well-known complication of surgery of the intervertebral disc. The epidural fibrous scar is the normal outcome of inflammatory activity secondary to the mechanical tissue disturbance resulting from surgery. In certain individuals, perhaps genetically predisposed as excessive quantity of fibrous tissue is deposited in the epi and/or nitradural space. This abnormal situation, comparable to cheloid cutaneous scars, is perhaps at the origin of the clinical symptoms. The authors report the clinical and radiological signs observed in 38 patients having had at least one operation for discal hernia, and who underwent further operations in the aim of freeing the roots and the dural sack from fibrous compression. Results of excision of the epidural "cheloid" were good in 13 cases, and average in 8 others. There was a complete failure in 17 other patients. Three explanations were offered to explain the frequency of the failures: 1) formation of a new cheloid, 2) difficulty of neurolysis of the arachnoiditis, 3) possibility of intrinsic lesions of the nerve associated with the epiduro-arachnoiditis.

  11. Repeatability and reproducibility of anterior chamber volume measurements using 3-dimensional corneal and anterior segment optical coherence tomography.

    Science.gov (United States)

    Fukuda, Shinichi; Kawana, Keisuke; Yasuno, Yoshiaki; Oshika, Tetsuro

    2011-03-01

    To evaluate the repeatability and reproducibility of anterior chamber volume (ACV) measurements using swept-source 3-dimensional corneal and anterior segment optical coherence tomography (CAS-OCT) and dual Scheimpflug imaging. Department of Ophthalmology, Institute of Clinical Medicine, University of Tsukuba, Ibaraki, Japan. Nonrandomized clinical trial. Measurements were taken in normal eyes (subject group) and in eyes with primary angle closure (PAC) (patient group). In the subject group, the entire ACV and the central 8.0 mm diameter ACV were measured using CAS-OCT and dual Scheimpflug imaging. In the patient group, the entire ACV and 8.0 mm ACV were measured using CAS-OCT. The coefficient of variation and intraclass correlation coefficient (ICC) were calculated to evaluate repeatability and reproducibility, and the correlation between the 2 devices was assessed. In the subject group, the mean 8.0 mm ACV was 110.14 mm(3) ± 12.57 (SD) using CAS-OCT and 114.51 ± 14.69 mm(3) using Scheimpflug imaging; there was a significant linear correlation (r = 0.878, P ACV on CAS-OCT was 165.15 ± 29.29 mm(3). The ICCs of the 8.0 mm and entire ACV measurements were greater than 0.94. The coefficients of repeatability and reproducibility of the 8.0 mm ACV and entire ACV measurements were less than 5%. In the patient group, the 8.0 mm and entire ACV measurements showed good reproducibility and repeatability. The CAS-OCT method allowed noninvasive measurement of the entire ACV with sufficient repeatability and reproducibility. The 8.0 mm ACV measurements with CAS-OCT and Scheimpflug imaging were comparable. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  12. Precision (Repeatability and Reproducibility and Agreement of Corneal Power Measurements Obtained by Topcon KR-1W and iTrace.

    Directory of Open Access Journals (Sweden)

    Yanjun Hua

    Full Text Available To evaluate the repeatability and reproducibility of corneal power measurements obtained by Topcon KR-1W and iTrace, and assess the agreement with measurements obtained by Allegro Topolyzer and IOLMaster.The right eyes of 100 normal subjects were prospectively scanned 3 times using all the 4 devices. Another observer performed additional 3 consecutive scans using the Topcon KR-1W and iTrace in the same session. About one week later, the first observer repeated the measurements using the Topcon KR-1W and iTrace. The steep keratometry (Ks, flat keratometry (Kf, mean keratometry (Km, J0 and J45 were analyzed. Repeatability and reproducibility of measurements were evaluated by the within-subject standard deviation (Sw, coefficient of variation (CoV, test-retest repeatability (2.77Sw, and intraclass correlation coefficient (ICC. Agreements between devices were assessed using Bland-Altman analysis and 95% limits of agreement (LoA.Intraobserver repeatability and interobserver and intersession reproducibility of the Ks, Kf and Km showed a CoV of no more than 0.5%, a 2.77Sw of 0.70 D or less, and an ICC of no less than 0.99. However, J0 and J45 showed poor intraobserver repeatability and interobserver and intersession reproducibility (all ICCs not greater than 0.446. Statistically significant differences existed between Topcon KR-1W and IOLMaster, Topcon KR-1W and iTrace, Topcon KR-1W and Topolyzer, iTrace and Topolyzer, iTrace and IOLMaster for Ks, Kf and Km measurements (all P < 0.05. The mean differences between Topcon KR-1W, iTrace, and the other 2 devices were small. The 95% LoA were approximately 1.0 D to 1.5 D for all measurements.The Ks, Kf and Km obtained by Topcon KR-1W and iTrace showed excellent intraobserver repeatability and interobserver and intersession reproducibility in normal eyes. The agreement between Topcon KR-1W and Topolyzer, Topcon KR-1W and IOLMaster, iTrace and Topolyzer, iTrace and IOLMaster, Topcon KR-1W and iTrace were not

  13. Recent results on Electroweak measurements from ATLAS

    Directory of Open Access Journals (Sweden)

    Benekos Nektarios Chr.

    2015-01-01

    Full Text Available ATLAS measurements of multiboson production processes involving combinations of W,Z and isolated photons are summarized. Measurements using data at 7 TeV and at 8 TeV are presented. The measurements are performed using leptonic decay modes, including the invisible decay Z → v v̅, as well as semileptonic channels. Measurements of single and diboson production in association with two forward jets is sensitive to electroweak vector boson fusion and scattering processes. An observation of the electroweak production of the Z boson and an evidence of same sign WW production are reported.

  14. Intergenic and repeat transcription in human, chimpanzee and macaque brains measured by RNA-Seq.

    Directory of Open Access Journals (Sweden)

    Augix Guohua Xu

    Full Text Available Transcription is the first step connecting genetic information with an organism's phenotype. While expression of annotated genes in the human brain has been characterized extensively, our knowledge about the scope and the conservation of transcripts located outside of the known genes' boundaries is limited. Here, we use high-throughput transcriptome sequencing (RNA-Seq to characterize the total non-ribosomal transcriptome of human, chimpanzee, and rhesus macaque brain. In all species, only 20-28% of non-ribosomal transcripts correspond to annotated exons and 20-23% to introns. By contrast, transcripts originating within intronic and intergenic repetitive sequences constitute 40-48% of the total brain transcriptome. Notably, some repeat families show elevated transcription. In non-repetitive intergenic regions, we identify and characterize 1,093 distinct regions highly expressed in the human brain. These regions are conserved at the RNA expression level across primates studied and at the DNA sequence level across mammals. A large proportion of these transcripts (20% represents 3'UTR extensions of known genes and may play roles in alternative microRNA-directed regulation. Finally, we show that while transcriptome divergence between species increases with evolutionary time, intergenic transcripts show more expression differences among species and exons show less. Our results show that many yet uncharacterized evolutionary conserved transcripts exist in the human brain. Some of these transcripts may play roles in transcriptional regulation and contribute to evolution of human-specific phenotypic traits.

  15. Understanding the Changing Global Distribution of Radiocarbon: What are we learning from the WOCE and CLIVAR Repeat Hydrography Results

    Science.gov (United States)

    McNichol, A. P.; Key, R. M.; Elder, K. L.; Von Reden, K. F.; Gagnon, A. R.; Burton, J. R.

    2016-02-01

    Radiocarbon (DI14C) is an important tracer for studies of ocean processes. It has been used to study mixing, ventilation rates, production rates, and residence times in the deep ocean, deep ocean biogeochemistry and oxygen utilization rates, air-sea gas exchange, thermocline ventilation rates, as a proxy for anthropogenic CO2 in the ocean, to estimate deep water mass ages for anthropogenic CO2 uptake and carbon studies, and to evaluate ocean general circulation model (OGCM) performance. DI14C has been used to study the aging of the water masses and calculate pre-bomb surface water values. DI14C has also been used with CFCs and anthropogenic CO2 to investigate the influence of eddies on mixing/ventilation in moderately high resolution ocean. More recently, it has been used to demonstrate the evolving applications of radiocarbon as the shock of the initial bomb-produced radiocarbon spike has passed through the surface ocean and upper thermocline. The radiocarbon distribution is now illuminating mechanisms, pathways and rates of 14C transfer into the lower thermocline and deeper levels. 14C results from over 28,000 samples taken as part of the WOCE and CLIVAR programs have been reported. Significant changes, well above the analytical uncertainty, are seen in all three major ocean basins. Simply mapping the distribution measured during the WOCE program provided new insights. In the Southern Ocean near the Antarctic coast, DI14C values in the western-most Pacific transect are much lower than those observed in the eastern transects. If this is a real feature (rather than a gridding artifact), it has important implications for understanding the role of the Southern Ocean in global climate change. Another extremely interesting feature is a break observed in the southward pointing tongue (NPDW) along the P16 line just west of the islands near 20-25S. It seems quite likely that this unexpected distribution is related to or controlled by proximity to the extreme topography in

  16. Repeatability of corticospinal and spinal measures during lengthening and shortening contractions in the human tibialis anterior muscle.

    Directory of Open Access Journals (Sweden)

    Jamie Tallent

    Full Text Available UNLABELLED: Elements of the human central nervous system (CNS constantly oscillate. In addition, there are also methodological factors and changes in muscle mechanics during dynamic muscle contractions that threaten the stability and consistency of transcranial magnetic stimulation (TMS and perpherial nerve stimulation (PNS measures. PURPOSE: To determine the repeatability of TMS and PNS measures during lengthening and shortening muscle actions in the intact human tibialis anterior. METHODS: On three consecutive days, 20 males performed lengthening and shortening muscle actions at 15, 25, 50 and 80% of maximal voluntary contraction (MVC. The amplitude of the Motor Evoked Potentials (MEPs produced by TMS was measured at rest and during muscle contraction at 90° of ankle joint position. MEPs were normalised to Mmax determined with PNS. The corticospinal silent period was recorded at 80% MVC. Hoffman reflex (H-reflex at 10% isometric and 25% shortening and lengthening MVCs, and V-waves during MVCs were also evoked on each of the three days. RESULTS: With the exception of MEPs evoked at 80% shortening MVC, all TMS-derived measures showed good reliability (ICC = 0.81-0.94 from days 2 to 3. Confidence intervals (CI, 95% were lower between days 2 and 3 when compared to days 1 and 2. MEPs significantly increased at rest from days 1 to 2 (P = 0.016 and days 1 to 3 (P = 0.046. The H-reflex during dynamic muscle contraction was reliable across the three days (ICC = 0.76-0.84. V-waves (shortening, ICC = 0.77, lengthening ICC = 0.54 and the H-reflex at 10% isometric MVC (ICC = 0.66 was generally less reliable over the three days. CONCLUSION: Although it is well known that measures of the intact human CNS exhibit moment-to-moment fluctuations, careful experimental arrangements make it possible to obtain consistent and repeatable measurements of corticospinal and spinal excitability in the actively lengthening and shortening human

  17. Heart failure re-admission: measuring the ever shortening gap between repeat heart failure hospitalizations.

    Directory of Open Access Journals (Sweden)

    Jeffrey A Bakal

    Full Text Available Many quality-of-care and risk prediction metrics rely on time to first rehospitalization even though heart failure (HF patients may undergo several repeat hospitalizations. The aim of this study is to compare repeat hospitalization models. Using a population-based cohort of 40,667 patients, we examined both HF and all cause re-hospitalizations using up to five years of follow-up. Two models were examined: the gap-time model which estimates the adjusted time between hospitalizations and a multistate model which considered patients to be in one of four states; community-dwelling, in hospital for HF, in hospital for any reason, or dead. The transition probabilities and times were then modeled using patient characteristics and number of repeat hospitalizations. We found that during the five years of follow-up roughly half of the patients returned for a subsequent hospitalization for each repeat hospitalization. Additionally, we noted that the unadjusted time between hospitalizations was reduced ∼40% between each successive hospitalization. After adjustment each additional hospitalization was associated with a 28 day (95% CI: 22-35 reduction in time spent out of hospital. A similar pattern was seen when considering the four state model. A large proportion of patients had multiple repeat hospitalizations. Extending the gap between hospitalizations should be an important goal of treatment evaluation.

  18. Transitory FGF treatment results in the long-lasting suppression of the proliferative response to repeated FGF stimulation.

    Science.gov (United States)

    Poole, Ashleigh; Knowland, Nicholas; Cooper, Emily; Cole, Rebecca; Wang, Hongchuan; Booth, Lucas; Kacer, Doreen; Tarantini, Francesca; Friesel, Robert; Prudovsky, Igor

    2014-05-01

    FGF applied as a single growth factor to quiescent mouse fibroblasts induces a round of DNA replication, however continuous stimulation results in arrest in the G1 phase of the next cell cycle. We hypothesized that FGF stimulation induces the establishment of cell memory, which prevents the proliferative response to repeated or continuous FGF application. When a 2-5 days quiescence period was introduced between primary and repeated FGF treatments, fibroblasts failed to efficiently replicate in response to secondary FGF application. The establishment of "FGF memory" during the first FGF stimulation did not require DNA synthesis, but was dependent on the activity of FGF receptors, MEK, p38 MAPK and NFκB signaling, and protein synthesis. While secondary stimulation resulted in strongly decreased replication rate, we did not observe any attenuation of morphological changes, Erk1/2 phosphorylation and cyclin D1 induction. However, secondary FGF stimulation failed to induce the expression of cyclin A, which is critical for the progression from G1 to S phase. Treatment of cells with a broad range histone deacetylase inhibitor during the primary FGF stimulation rescued the proliferative response to the secondary FGF treatment suggesting that the establishment of "FGF memory" may be based on epigenetic changes. We suggest that "FGF memory" can prevent the hyperplastic response to cell damage and inflammation, which are associated with an enhanced FGF production and secretion. "FGF memory" may present a natural obstacle to the efficient application of recombinant FGFs for the treatment of ulcers, ischemias, and wounds.

  19. Splashing Our Way to Playfulness! An Aquatic Playgroup for Young Children with Autism, A Repeated Measures Design

    Science.gov (United States)

    Fabrizi, Sarah E.

    2015-01-01

    This study investigated the effectiveness of an aquatic playgroup on the playfulness of children, ages 2 to 3 with autism spectrum disorder. Using a repeated measures design, we followed 10 children and their caregivers who participated in a 6-week aquatic playgroup in southwest Florida. Four dyads completed the entire 12-week study period. The…

  20. Splashing Our Way to Playfulness! An Aquatic Playgroup for Young Children with Autism, A Repeated Measures Design

    Science.gov (United States)

    Fabrizi, Sarah E.

    2015-01-01

    This study investigated the effectiveness of an aquatic playgroup on the playfulness of children, ages 2 to 3 with autism spectrum disorder. Using a repeated measures design, we followed 10 children and their caregivers who participated in a 6-week aquatic playgroup in southwest Florida. Four dyads completed the entire 12-week study period. The…

  1. A Correction for the Epsilon Approximate Test in Repeated Measures Designs with Two or More Independent Groups.

    Science.gov (United States)

    Lecoutre, Bruno

    1991-01-01

    The routine epsilon approximate test in repeated measures designs when the condition of circularity is unfulfilled uses an erroneous formula in the case of two or more groups. Because this may lead to underestimation of the deviation from circularity when the subject number is small, a correction is proposed. (Author/SLD)

  2. Repeatability of swept-source optical coherence tomography retinal and choroidal thickness measurements in neovascular age-related macular degeneration

    DEFF Research Database (Denmark)

    Hanumunthadu, Daren; Ilginis, Tomas; Restori, Marie

    2017-01-01

    BACKGROUND: The aim was to determine the intrasession repeatability of swept-source optical coherence tomography (SS-OCT)-derived retinal and choroidal thickness measurements in eyes with neovascular age-related macular degeneration (nAMD). METHODS: A prospective study consisting of patients with...

  3. Insertion of reticuloendotheliosis virus long terminal repeat into CVI988 strain of Marek’s disease virus results in enhanced growth and protection

    Science.gov (United States)

    It has been reported that co-cultivation of a JM/102W strain, a virulent strain of Marek’s disease virus (MDV), with reticuloendotheliosis virus (REV) resulted in the integration of REV long terminal repeat (LTR) into the MDV repeat region. The resulting virus, RM1, was unable to transform T-cells ...

  4. Pilot study: Assessing repeatability of the EcoWalk platform resistive pressure sensors to measure plantar pressure during barefoot standing

    Science.gov (United States)

    Zequera, Martha; Perdomo, Oscar; Wilches, Carlos; Vizcaya, Pedro

    2013-06-01

    Plantar pressure provides useful information to assess the feet's condition. These systems have emerged as popular tools in clinical environment. These systems present errors and no compensation information is presented by the manufacturer, leading to uncertainty in the measurements. Ten healthy subjects, 5 females and 5 males, were recruited. Lateral load distribution, antero-posterior load distribution, average pressure, contact area, and force were recorded. The aims of this study were to assess repeatability of the EcoWalk system and identify the range of pressure values observed in the normal foot. The coefficient of repeatability was less than 4% for all parameters considered.

  5. Combined risk measures: representation results and applications

    NARCIS (Netherlands)

    Göttsche, Ove Ernst

    2014-01-01

    The analysis and interpretation of risk play a crucial role in different areas of modern finance. This includes pricing of financial products, capital allocation and derivation of economic capital. Key to this analysis is the quantification of the risk via risk measures. A promising approach is to d

  6. Reliability of near-infrared spectroscopy for measuring biceps brachii oxygenation during sustained and repeated isometric contractions

    Science.gov (United States)

    Muthalib, Makii; Millet, Guillaume Y.; Quaresima, Valentina; Nosaka, Kazunori

    2010-01-01

    We examine the test-retest reliability of biceps brachii tissue oxygenation index (TOI) parameters measured by near-infrared spectroscopy during a 10-s sustained and a 30-repeated (1-s contraction, 1-s relaxation) isometric contraction task at 30% of maximal voluntary contraction (30% MVC) and maximal (100% MVC) intensities. Eight healthy men (23 to 33 yr) were tested on three sessions separated by 3 h and 24 h, and the within-subject reliability of torque and each TOI parameter were determined by Bland-Altman+/-2 SD limits of agreement plots and coefficient of variation (CV). No significant (P>0.05) differences between the three sessions were found for mean values of torque and TOI parameters during the sustained and repeated tasks at both contraction intensities. All TOI parameters were within+/-2 SD limits of agreement. The CVs for torque integral were similar between the sustained and repeated task at both intensities (4 to 7%) however, the CVs for TOI parameters during the sustained and repeated task were lower for 100% MVC (7 to 11%) than for 30% MVC (22 to 36%). It is concluded that the reliability of the biceps brachii NIRS parameters during both sustained and repeated isometric contraction tasks is acceptable.

  7. Association between proton magnetic resonance spectroscopy measurements and CAG repeat number in patients with spinocerebellar ataxias 2, 3, or 6.

    Directory of Open Access Journals (Sweden)

    Po-Shan Wang

    Full Text Available The aim of this study was to correlate magnetic resonance spectroscopy (MRS measurements, including that for the N-acetyl aspartate (NAA/creatine (Cr ratio in the vermis (denoted V-NAA, right cerebellar hemisphere (R-NAA, and left (L-NAA cerebellar hemisphere, with the clinical scale for the assessment and rating of ataxia (SARA score for patients with spinocerebellar ataxia (SCA types 2, 3, and 6. A total of 24 patients with SCA2, 48 with SCA3, and 16 with SCA6 were recruited; 12 patients with SCA2, 43 with SCA3, and 8 with SCA6 underwent detailed magnetic resonance neuroimaging. Forty-four healthy, age-matched individuals without history of neurologic disease served as control subjects. V-NAA and patient age were used to calculate the predicted age at which a patient with SCA2 or SCA3 would reach an onset V-NAA value. Results showed the following: the NAA/Cr ratio decreased with increasing age in patients with SCA but not in control subjects; the SARA score increased progressively with age and duration of illness; V-NAA showed a better correlation with SARA score than R-NAA in patients with SCA2 or SCA3; the ratio of age to V-NAA correlated well with CAG repeat number; the retrospectively predicted age of onset for SCA2 and SCA3 was consistent with patient-reported age of onset; R-NAA showed a better correlation with SARA score than V-NAA in patients with SCA6; V-NAA and R-NAA correlated with clinical severity (SARA score in patients with SCA. The correlation between CAG repeat number and age could be expressed as a simple linear function, which might explain previous observations claiming that the greater the CAG repeat number, the earlier the onset of illness and the faster the disease progression. These findings support the use of MRS values to predict age of disease onset and to retrospectively evaluate the actual age of disease onset in SCA.

  8. Association between proton magnetic resonance spectroscopy measurements and CAG repeat number in patients with spinocerebellar ataxias 2, 3, or 6.

    Science.gov (United States)

    Wang, Po-Shan; Chen, Hung-Chieh; Wu, Hsiu-Mei; Lirng, Jiing-Feng; Wu, Yu-Te; Soong, Bing-Wen

    2012-01-01

    The aim of this study was to correlate magnetic resonance spectroscopy (MRS) measurements, including that for the N-acetyl aspartate (NAA)/creatine (Cr) ratio in the vermis (denoted V-NAA), right cerebellar hemisphere (R-NAA), and left (L-NAA) cerebellar hemisphere, with the clinical scale for the assessment and rating of ataxia (SARA) score for patients with spinocerebellar ataxia (SCA) types 2, 3, and 6. A total of 24 patients with SCA2, 48 with SCA3, and 16 with SCA6 were recruited; 12 patients with SCA2, 43 with SCA3, and 8 with SCA6 underwent detailed magnetic resonance neuroimaging. Forty-four healthy, age-matched individuals without history of neurologic disease served as control subjects. V-NAA and patient age were used to calculate the predicted age at which a patient with SCA2 or SCA3 would reach an onset V-NAA value. Results showed the following: the NAA/Cr ratio decreased with increasing age in patients with SCA but not in control subjects; the SARA score increased progressively with age and duration of illness; V-NAA showed a better correlation with SARA score than R-NAA in patients with SCA2 or SCA3; the ratio of age to V-NAA correlated well with CAG repeat number; the retrospectively predicted age of onset for SCA2 and SCA3 was consistent with patient-reported age of onset; R-NAA showed a better correlation with SARA score than V-NAA in patients with SCA6; V-NAA and R-NAA correlated with clinical severity (SARA score) in patients with SCA. The correlation between CAG repeat number and age could be expressed as a simple linear function, which might explain previous observations claiming that the greater the CAG repeat number, the earlier the onset of illness and the faster the disease progression. These findings support the use of MRS values to predict age of disease onset and to retrospectively evaluate the actual age of disease onset in SCA.

  9. Detection of quasi-periodic processes in repeated measurements: New approach for the fitting and clusterization of different data

    Science.gov (United States)

    Nigmatullin, R.; Rakhmatullin, R.

    2014-12-01

    Many experimentalists were accustomed to think that any independent measurement forms a non-correlated measurement that depends weakly from others. We are trying to reconsider this conventional point of view and prove that similar measurements form a strongly-correlated sequence of random functions with memory. In other words, successive measurements "remember" each other at least their nearest neighbors. This observation and justification on real data help to fit the wide set of data based on the Prony's function. The Prony's decomposition follows from the quasi-periodic (QP) properties of the measured functions and includes the Fourier transform as a partial case. New type of decomposition helps to obtain a specific amplitude-frequency response (AFR) of the measured (random) functions analyzed and each random function contains less number of the fitting parameters in comparison with its number of initial data points. Actually, the calculated AFR can be considered as the generalized Prony's spectrum (GPS), which will be extremely useful in cases where the simple model pretending on description of the measured data is absent but vital necessity of their quantitative description is remained. These possibilities open a new way for clusterization of the initial data and new information that is contained in these data gives a chance for their detailed analysis. The electron paramagnetic resonance (EPR) measurements realized for empty resonator (pure noise data) and resonator containing a sample (CeO2 in our case) confirmed the existence of the QP processes in reality. But we think that the detection of the QP processes is a common feature of many repeated measurements and this new property of successive measurements can attract an attention of many experimentalists. To formulate some general conditions that help to identify and then detect the presence of some QP process in the repeated experimental measurements. To find a functional equation and its solution that

  10. Young investigator challenge: Atypia of undetermined significance in thyroid FNA: Standardized terminology without standardized management--a closer look at repeat FNA and quality measures.

    Science.gov (United States)

    Brandler, Tamar C; Aziz, Mohamed S; Coutsouvelis, Constantinos; Rosen, Lisa; Rafael, Oana C; Souza, Fabiola; Jelloul, Fatima-Zahra; Klein, Melissa A

    2016-01-01

    The Bethesda system (TBS) for the reporting of thyroid cytopathology established the category of atypia of undetermined significance (AUS) with a 7% target rate and a 5% to 15% implied malignancy risk. Recent literature has reported a broad range of AUS rates, subsequent malignancy rates, and discrepant results from repeat fine-needle aspiration (FNA) versus surgical follow-up. Therefore, this study examined AUS data from the Hofstra North Shore-LIJ School of Medicine to determine the best clinical follow-up. Thyroid aspirates interpreted as AUS in 2012-2014 at the Hofstra North Shore-LIJ School of Medicine were collected. Repeat FNA and surgical follow-up data were tabulated to establish AUS, secondary AUS (diagnosed upon repeat FNA follow-up of a primary FNA AUS diagnosis), atypia of undetermined significance/malignancy (AUS:M) ratios (according to the TBS categories), and malignancy rates for AUS. The AUS rate was 8.5% (976/11,481), and there was follow-up data for 545 cases. The AUS:M ratio was 2.0. Repeat FNA was performed for 281 cases; 57 proceeded to surgical intervention. Repeat FNA reclassified 71.17% of the cases. The malignancy rates for AUS cases proceeding directly to surgery and for those receiving a surgical intervention after a repeat AUS diagnosis were 33.33% and 43.75%, respectively. Repeat FNA resulted in definitive diagnostic reclassification for 67.61% of primary AUS cases and reduced the number of patients triaged to surgery, with 56.58% of the cases recategorized as benign. Cases undergoing surgery after repeat AUS had a higher malignancy rate than those going straight to surgery, and this emphasizes the value of repeat FNA in selecting surgical candidates. In addition, this study highlights the utility of AUS rate monitoring as a quality measure that has contributed to the ability of the Hofstra North Shore-LIJ School of Medicine to adhere closely to TBS recommendations. © 2016 American Cancer Society.

  11. Power analysis for multivariate and repeated measurements designs via SPSS: correction and extension of D'Amico, Neilands, and Zambarano (2001).

    Science.gov (United States)

    Osborne, Jason W

    2006-05-01

    D'Amico, Neilands, and Zambarano (2001) published SPSS syntax to perform power analyses for three complex procedures: ANCOVA, MANOVA, and repeated measures ANOVA. Unfortunately, the published SPSS syntax for performing the repeated measures analysis needed some minor revision in order to perform the analysis correctly. This article presents the corrected syntax that will successfully perform the repeated measures analysis and provides some guidance on modifying the syntax to customize the analysis.

  12. Three dimensional measurement of rhinoplasty results.

    NARCIS (Netherlands)

    Heerbeek, N. van; Ingels, K.J.A.O.; Loon, B. van; Plooij, J.M.; Berge, S.J.

    2009-01-01

    BACKGROUND: Pre- and postoperative imaging is important and essential for evaluation of the results of rhinoplasty surgery. Two-dimensional photographs are used routinely for this purpose, but have several disadvantages as opposed to three-dimensional imaging techniques, such as

  13. Selecting a linear mixed model for longitudinal data: repeated measures analysis of variance, covariance pattern model, and growth curve approaches.

    Science.gov (United States)

    Liu, Siwei; Rovine, Michael J; Molenaar, Peter C M

    2012-03-01

    With increasing popularity, growth curve modeling is more and more often considered as the 1st choice for analyzing longitudinal data. Although the growth curve approach is often a good choice, other modeling strategies may more directly answer questions of interest. It is common to see researchers fit growth curve models without considering alterative modeling strategies. In this article we compare 3 approaches for analyzing longitudinal data: repeated measures analysis of variance, covariance pattern models, and growth curve models. As all are members of the general linear mixed model family, they represent somewhat different assumptions about the way individuals change. These assumptions result in different patterns of covariation among the residuals around the fixed effects. In this article, we first indicate the kinds of data that are appropriately modeled by each and use real data examples to demonstrate possible problems associated with the blanket selection of the growth curve model. We then present a simulation that indicates the utility of Akaike information criterion and Bayesian information criterion in the selection of a proper residual covariance structure. The results cast doubt on the popular practice of automatically using growth curve modeling for longitudinal data without comparing the fit of different models. Finally, we provide some practical advice for assessing mean changes in the presence of correlated data.

  14. Repeatability of swept-source optical coherence tomography retinal and choroidal thickness measurements in neovascular age-related macular degeneration.

    Science.gov (United States)

    Hanumunthadu, Daren; Ilginis, Tomas; Restori, Marie; Sagoo, Mandeep S; Tufail, Adnan; Balaggan, Kamaljit S; Patel, Praveen J

    2017-05-01

    The aim was to determine the intrasession repeatability of swept-source optical coherence tomography (SS-OCT)-derived retinal and choroidal thickness measurements in eyes with neovascular age-related macular degeneration (nAMD). A prospective study consisting of patients with active nAMD enrolled in the Distance of Choroid Study at Moorfields Eye Hospital, London. Patients underwent three 12×9 mm macular raster scans using the deep range imaging (DRI) OCT-1 SS-OCT (Topcon) device in a single imaging session. Retinal and choroidal thicknesses were calculated for the ETDRS macular subfields. Repeatability was calculated according to methods described by Bland and Altman. 39 eyes of 39 patients with nAMD were included with a mean (±SD) age of 73.9 (±7.2) years. The mean (±SD) retinal thickness of the central macular subfield was 225.7 μm (±12.4 μm). The repeatability this subfield, expressed as a percentage of the mean central macular subfield thickness, was 23.2%. The percentage repeatability of the other macular subfields ranged from 13.2% to 28.7%. The intrasession coefficient of repeatability of choroidal thickness of the central macular subfield was 57.2 μm with a mean choroidal thickness (±SD) of 181 μm (±15.8 μm). This study suggests that a change >23.2% of retinal thickness and 57.2 μm choroidal thickness in the central macular subfield is required to distinguish true clinical change from measurement variability when using the DRI OCT-1 device to manage patients with nAMD. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  15. Extended fluctuation theorems for repeated measurements and feedback within Hamiltonian framework

    Energy Technology Data Exchange (ETDEWEB)

    Lahiri, Sourabh, E-mail: sourabhlahiri@gmail.com [Laboratoire de Physico-Chimie Théorique, ESPCI, 10 rue Vauquelin, F-75231 Paris (France); Jayannavar, A.M. [Institute of Physics, Sachivalaya Marg, Bhubaneswar 751005 (India)

    2016-04-29

    We derive the extended fluctuation theorems in presence of multiple measurements and feedback, when the system is governed by Hamiltonian dynamics. We use only the forward phase space trajectories in the derivation. However, to obtain an expression for the efficacy parameter, we must necessarily use the notion of reverse trajectory. Our results show that the correction term appearing in the exponent of the extended fluctuation theorems is non-unique, whereas the physical meaning of the efficacy parameter is unique. - Highlights: • Extended Fluctuation Theorems under multiple measurements and feedback have been derived using Hamiltonian dynamics. • We prove the theorems without using the notion of reverse trajectory. • We show that the correction terms are not unique. • The efficacy parameter is shown to have a unique physical meaning.

  16. Comparison of Central Corneal Thickness Measurements by Ultrasonic Pachymetry and Orbscan II Corneal Topography and Evaluation of Ultrasonic Pachymetry Repeatability

    OpenAIRE

    Semra Tiryaki Demir; Mahmut Odabaşı; Mehmet Ersin Oba; Ayşe Burcu Dirim; Efe Can; Orhan Kara

    2014-01-01

    Objectives: Comparison of central corneal thickness (CCT) measurements by ultrasonic pachymetry and Orbscan II corneal topography and evaluation of ultrasonic pachymetry repeatability for same observer. Materials and Methods: The study included 132, 82, and 80 eyes of 66 patients with primary open-angle glaucoma (POAG), 41 patients with ocular hypertension (OHT), and 40 controls, respectively. All subjects were subjected to routine ophthalmic examination. Orbscan II (Bausch&Lomb) ...

  17. Therapeutic results and safety of postoperative radiotherapy for keloid after repeated Cesarean section in immediate postpartum period

    Energy Technology Data Exchange (ETDEWEB)

    Kim Ju Ree; Lee, Sang Hoon [Cheil General Hospital and Women' s Healthcare Center, Kwandong University College of Medicine, Seoul (Korea, Republic of)

    2012-06-15

    To evaluate the effectiveness and safety of postoperative radiotherapy for the treatment of keloid scars administered immediately after Cesarean section. A total of 26 postpartum patients with confirmed keloids resulting from previous Cesarean sections received either 12 or 15 Gy radiotherapy. The radiotherapy was divided into three 6 MeV electron beam fractions administered during the postpartum period immediately following the fi nal Cesarean section. To evaluate ovarian safety, designated doses of radiation were estimated at the calculated depth of the ovaries using a solid plate phantom and an ionization chamber with the same lead cutout as was used for the treatment of Cesarean section operative scars and a tissue equivalent bolus. In total, the control rate was 77% (20 patients), while six (23%) developed focally elevated keloids (ranging from 0.5 to 2 cm in length) in the middle of the primary abdominal scar. Five patients experienced mild hyperpigmentation. Nonetheless, most patients (96%) were satisfied with the treatment results. The estimated percentage of the applied radiation doses that reached the calculated depth of the ovaries ranged from 0.0033% to 0.0062%. When administered during the immediate postpartum period, postoperative electron beam radiotherapy for repeated Cesarean section scars is generally safe and produces good cosmetic results with minimal toxicity.

  18. Measuring Aseismic Slip through Characteristically Repeating Earthquakes at the Mendocino Triple Junction, Northern California

    Science.gov (United States)

    Materna, K.; Taira, T.; Burgmann, R.

    2016-12-01

    The Mendocino Triple Junction (MTJ), at the transition point between the San Andreas fault system, the Mendocino Transform Fault, and the Cascadia Subduction Zone, undergoes rapid tectonic deformation and produces more large (M>6.0) earthquakes than any region in California. Most of the active faults of the triple junction are located offshore, making it difficult to characterize both seismic slip and aseismic creep. In this work, we study aseismic creep rates near the MTJ using characteristically repeating earthquakes (CREs) as indicators of creep rate. CREs are generally interpreted as repeated failures of the same seismic patch within an otherwise creeping fault zone; as a consequence, the magnitude and recurrence time of the CREs can be used to determine a fault's creep rate through empirically calibrated scaling relations. Using seismic data from 2010-2016, we identify CREs as recorded by an array of eight 100-Hz PBO borehole seismometers deployed in the Cape Mendocino area. For each event pair with epicenters less than 30 km apart, we compute the cross-spectral coherence of 20 seconds of data starting one second before the P-wave arrival. We then select pairs with high coherence in an appropriate frequency band, which is determined uniquely for each event pair based on event magnitude, station distance, and signal-to-noise ratio. The most similar events (with median coherence above 0.95 at two or more stations) are selected as CREs and then grouped into CRE families, and each family is used to infer a local creep rate. On the Mendocino Transform Fault, we find relatively high creep rates of >5 cm/year that increase closer to the Gorda Ridge. Closer to shore and to the MTJ itself, we find many families of repeaters on and off the transform fault with highly variable creep rates, indicative of the complex deformation that takes place there.

  19. Persistent repeated measurements by magnetic resonance spectroscopy demonstrate minimal hepatic encephalopathy: a case report.

    Science.gov (United States)

    Scheau, C; Popa, G A; Ghergus, A E; Preda, E M; Capsa, R A; Lupescu, I G

    2013-09-15

    Minimal Hepatic Encephalopathy (MHE), previously referred to as infraclinical or subclinical is a precursor in the development of clinical hepatic encephalopathy (HE). The demonstration of MHE is done through neuropsychological testing in the absence of clinical evidence of HE, patients showing only a mild cognitive impairment. Neuropsychological tests employed consist of Repeatable Battery for the Assessment of Neuropsychological Status (RBANS) and portosystemic encephalopathy (PSE) test score. Unfortunately, there are numerous occasions when the tests prove irrelevant: in the situation of inexperienced investigators, the patient's poor education, vision problems or concurring central nervous system disease, all of which may delay or deviate from the correct diagnosis.

  20. Composite tube and plate manufacturing repeatability as determined by precision measurements of thermal strain

    Science.gov (United States)

    Riddle, Lenn A.; Tucker, James R.; Bluth, A. Marcel

    2013-09-01

    Composite materials often carry the reputation of demonstrating high variability in critical material properties. The JWST telescope metering structure is fabricated of several thousand separate composite piece parts. The stringent dimensional stability requirements on the metering structure require the critical thermal strain response of every composite piece be verified either at the billet or piece part level. JWST is a unique composite space structure in that it has required the manufacturing of several hundred composite billets that cover many lots of prepreg and many years of fabrication. The flight billet thermal expansion acceptance criteria limits the coefficient of thermal expansion (CTE) to a tolerance ranging between +/-0.014 ppm/K to +/-0.04 ppm/K around a prescribed nominal when measured from 293 K down to 40 K. The different tolerance values represent different material forms including flat plates and different tube cross-section dimensions. A precision measurement facility was developed that could measure at the required accuracy and at a pace that supported the composite part fabrication rate. The test method and facility is discussed and the results of a statistical process analysis of the flight composite billets are surveyed.

  1. Are exhaled nitric oxide measurements using the portable NIOX MINO repeatable?

    Directory of Open Access Journals (Sweden)

    Raza Abid

    2010-04-01

    Full Text Available Abstract Background Exhaled nitric oxide is a non-invasive marker of airway inflammation and a portable analyser, the NIOX MINO (Aerocrine AB, Solna, Sweden, is now available. This study aimed to assess the reproducibility of the NIOX MINO measurements across age, sex and lung function for both absolute and categorical exhaled nitric oxide values in two distinct groups of children and teenagers. Methods Paired exhaled nitric oxide readings were obtained from 494 teenagers, aged 16-18 years, enrolled in an unselected birth cohort and 65 young people, aged 6-17 years, with asthma enrolled in an interventional asthma management study. Results The birth cohort participants showed a high degree of variability between first and second exhaled nitric oxide readings (mean intra-participant difference 1.37 ppb, 95% limits of agreement -7.61 to 10.34 ppb, although there was very close agreement when values were categorised as low, normal, intermediate or high (kappa = 0.907, p Conclusions The reproducibility of exhaled nitric oxide is poor for absolute values but acceptable when values are categorised as low, normal, intermediate or high in children and teenagers. One measurement is therefore sufficient when using categorical exhaled nitric oxide values to direct asthma management but a mean of at least two measurements is required for absolute values.

  2. Measuring Spatial Infiltration in Stormwater Control Measures: Results and Implications

    Science.gov (United States)

    This presentation will provide background information on research conducted by EPA-ORD on the use of soil moisture sensors in bioretention/bioinfiltration technologies to evaluate infiltration mechanisms and compares monitoring results to simplified modeling assumptions. A serie...

  3. Ambient particulate air pollution and circulating antioxidant enzymes: A repeated-measure study in healthy adults in Beijing, China.

    Science.gov (United States)

    Wu, Shaowei; Wang, Bin; Yang, Di; Wei, Hongying; Li, Hongyu; Pan, Lu; Huang, Jing; Wang, Xin; Qin, Yu; Zheng, Chanjuan; Shima, Masayuki; Deng, Furong; Guo, Xinbiao

    2016-01-01

    The association of systemic antioxidant activity with ambient air pollution has been unclear. A panel of 40 healthy college students underwent repeated blood collection for 12 occasions under three exposure scenarios before and after relocating from a suburban area to an urban area in Beijing, China in 2010-2011. We measured various air pollutants including fine particles (PM2.5) and determined circulating levels of antioxidant enzymes extracellular superoxide dismutase (EC-SOD) and glutathione peroxidase 1 (GPX1) in the laboratory. An interquartile range increase of 63.4 μg/m(3) at 3-d PM2.5 moving average was associated with a 6.3% (95% CI: 0.6, 12.4) increase in EC-SOD and a 5.5% (95% CI: 1.3, 9.8) increase in GPX1. Several PM2.5 chemical constituents, including negative ions (nitrate and chloride) and metals (e.g., iron and strontium), were consistently associated with increases in EC-SOD and GPX1. Our results support activation of circulating antioxidant enzymes following exposure to particulate air pollution. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Are diagnostic criteria for acute malnutrition affected by hydration status in hospitalized children? A repeated measures study

    Directory of Open Access Journals (Sweden)

    Fegan Gregory

    2011-09-01

    Full Text Available Abstract Introduction Dehydration and malnutrition commonly occur together among ill children in developing countries. Dehydration (change in total body water is known to alter weight. Although muscle tissue has high water content, it is not known whether mid-upper arm circumference (MUAC may be altered by changes in tissue hydration. We aimed to determine whether rehydration alters MUAC, MUAC Z score (MUACz, weight-for-length Z-score (WFLz and classification of nutritional status among hospitalised Kenyan children admitted with signs of dehydration. Study procedure We enrolled children aged from 3 months to 5 years admitted to a rural Kenyan district hospital with clinical signs compatible with dehydration, and without kwashiorkor. Anthropometric measurements were taken at admission and repeated after 48 hours of treatment, which included rehydration by WHO protocols. Changes in weight observed during this period were considered to be due to changes in hydration status. Results Among 325 children (median age 11 months the median weight gain (rehydration after 48 hours was 0.21 kg, (an increase of 2.9% of admission body weight. Each 1% change in weight was associated with a 0.40 mm (95% CI: 0.30 to 0.44 mm, p Conclusion MUAC is less affected by dehydration than WFLz and is therefore more suitable for nutritional assessment of ill children. However, both WFLz and MUAC misclassify SAM among dehydrated children. Nutritional status should be re-evaluated following rehydration, and management adjusted accordingly.

  5. Discrepancies in reporting the CAG repeat lengths for Huntington's disease

    DEFF Research Database (Denmark)

    Quarrell, Oliver W; Handley, Olivia; O'Donovan, Kirsty

    2011-01-01

    Huntington's disease results from a CAG repeat expansion within the Huntingtin gene; this is measured routinely in diagnostic laboratories. The European Huntington's Disease Network REGISTRY project centrally measures CAG repeat lengths on fresh samples; these were compared with the original...

  6. Repeated, Intermittent Social Defeat across the Entire Juvenile Period Resulted in Behavioral, Physiological, Hormonal, Immunological, and Neurochemical Alterations in Young Adult Male Golden Hamsters.

    Science.gov (United States)

    Yu, Wei-Chun; Liu, Ching-Yi; Lai, Wen-Sung

    2016-01-01

    The developing brain is vulnerable to social defeat during the juvenile period. As complements of human studies, animal models of social defeat provide a straightforward approach to investigating the functional and neurobiological consequences of social defeats. Taking advantage of agonist behavior and social defeat in male golden hamster, a set of 6 experiments was conducted to investigate the consequences at multiple levels in young adulthood resulting from repeated, intermittent social defeats or "social threats" across the entire juvenile period. Male hamsters at postnatal day 28 (P28) were randomly assigned to either the social defeat, "social threat", or arena control group, and they correspondingly received a series of nine social interaction trials (i.e., either social defeat, "social threat", or arena control conditions) from P33 to P66. At the behavioral level (Experiment 1), we found that repeated social defeats (but not "social threats") significantly impacted locomotor activity in the familiar context and social interaction in the familiar/unfamiliar social contexts. At the physiological and hormonal levels (Experiments 2 and 3), repeated social defeat significantly enhanced the cortisol and norepinephrine concentrations in blood. Enlargement of the spleen was also found in the social defeat and "social threat" groups. At the immunological level (Experiment 4), the social defeat group showed lower levels of pro-inflammatory cytokines in the hypothalamus and hippocampus but higher concentration of IL-6 in the striatum compared to the other two groups. At the neurochemical level (Experiment 5), the socially defeated hamsters mainly displayed reductions of dopamine, dopamine metabolites, and 5-HT levels in the striatum and decreased level of 5-HT in the hippocampus. In Experiment 6, an increase in the spine density of hippocampal CA1 pyramidal neurons was specifically observed in the "social threat" group. Collectively, our findings indicate that repeated

  7. Reticulate phylogeny of gastropod-shell-breeding cichlids from Lake Tanganyika – the result of repeated introgressive hybridization

    Directory of Open Access Journals (Sweden)

    Blanc Michel

    2007-01-01

    Full Text Available Abstract Background The tribe Lamprologini is the major substrate breeding lineage of Lake Tanganyika's cichlid species flock. Among several different life history strategies found in lamprologines, the adaptation to live and breed in empty gastropod shells is probably the most peculiar. Although shell-breeding arose several times in the evolutionary history of the lamprologines, all obligatory and most facultative shell-breeders belong to the so called "ossified group", a monophyletic lineage within the lamprologine cichlids. Since their distinctive life style enables these species to live and breed in closest vicinity, we hypothesized that these cichlids might be particularly prone to accidental hybridization, and that introgression might have affected the evolutionary history of this cichlid lineage. Results Our analyses revealed discrepancies between phylogenetic hypotheses based on mitochondrial and nuclear (AFLP data. While the nuclear phylogeny was congruent with morphological, behavioral and ecological characteristics, several species – usually highly specialized shell-breeders – were placed at contradicting positions in the mitochondrial phylogeny. The discordant phylogenies strongly suggest repeated incidents of introgressive hybridization between several distantly related shell-breeding species, which reticulated the phylogeny of this group of cichlids. Long interior branches and high bootstrap support for many interior nodes in the mitochondrial phylogeny argue against a major effect of ancient incomplete lineage sorting on the phylogenetic reconstruction. Moreover, we provide morphological and genetic (mtDNA and microsatellites evidence for ongoing hybridization among distantly related shell-breeders. In these cases, the territorial males of the inferred paternal species are too large to enter the shells of their mate, such that they have to release their sperm over the entrance of the shell to fertilize the eggs. With sperm

  8. Measurement repeatability of tibial tuberosity-trochlear groove offset distance in red fox (Vulpes vulpes) cadavers

    DEFF Research Database (Denmark)

    Miles, James Edward; Jensen, Bente Rona; Kirpensteijn, Jolle

    2013-01-01

    Objective-To describe CT image reconstruction criteria for measurement of the tibial tuberosity-trochlear groove (TT-TG) offset distance, evaluate intra- and inter-reconstruction repeatability, and identify key sources of error in the measurement technique, as determined in vulpine hind limbs. An...... and applied criteria. The TT-TG offset distance has potential as an objective assessment of alignment of the distal portion of the quadriceps mechanism; its use as an aid in case selection for corrective femoral osteotomy among dogs with medial patellar luxation warrants investigation....

  9. Psychological impact and recovery after involvement in a patient safety incident: a repeated measures analysis

    Science.gov (United States)

    Van Gerven, Eva; Bruyneel, Luk; Panella, Massimiliano; Euwema, Martin; Sermeus, Walter; Vanhaecht, Kris

    2016-01-01

    Objective To examine individual, situational and organisational aspects that influence psychological impact and recovery of a patient safety incident on physicians, nurses and midwives. Design Cross-sectional, retrospective surveys of physicians, midwives and nurses. Setting 33 Belgian hospitals. Participants 913 clinicians (186 physicians, 682 nurses, 45 midwives) involved in a patient safety incident. Main outcome measures The Impact of Event Scale was used to retrospectively measure psychological impact of the safety incident at the time of the event and compare it with psychological impact at the time of the survey. Results Individual, situational as well as organisational aspects influenced psychological impact and recovery of a patient safety incident. Psychological impact is higher when the degree of harm for the patient is more severe, when healthcare professionals feel responsible for the incident and among female healthcare professionals. Impact of degree of harm differed across clinicians. Psychological impact is lower among more optimistic professionals. Overall, impact decreased significantly over time. This effect was more pronounced for women and for those who feel responsible for the incident. The longer ago the incident took place, the stronger impact had decreased. Also, higher psychological impact is related with the use of a more active coping and planning coping strategy, and is unrelated to support seeking coping strategies. Rendered support and a support culture reduce psychological impact, whereas a blame culture increases psychological impact. No associations were found with job experience and resilience of the health professional, the presence of a second victim support team or guideline and working in a learning culture. Conclusions Healthcare organisations should anticipate on providing their staff appropriate and timely support structures that are tailored to the healthcare professional involved in the incident and to the specific

  10. Understanding how adherence goals promote adherence behaviours: a repeated measure observational study with HIV seropositive patients

    Directory of Open Access Journals (Sweden)

    Jones Gareth

    2012-08-01

    Full Text Available Abstract Background The extent to which patients follow treatments as prescribed is pivotal to treatment success. An exceptionally high level (> 95% of HIV medication adherence is required to suppress viral replication and protect the immune system and a similarly high level (> 80% of adherence has also been suggested in order to benefit from prescribed exercise programmes. However, in clinical practice, adherence to both often falls below the desirable level. This project aims to investigate a wide range of psychological and personality factors that may lead to adherence/non-adherence to medical treatment and exercise programmes. Methods HIV positive patients who are referred to the physiotherapist-led 10-week exercise programme as part of the standard care are continuously recruited. Data on social cognitive variables (attitude, intention, subjective norms, self-efficacy, and outcome beliefs about the goal and specific behaviours, selected personality factors, perceived quality of life, physical activity, self-reported adherence and physical assessment are collected at baseline, at the end of the exercise programme and again 3 months later. The project incorporates objective measures of both exercise (attendance log and improvement in physical measures such as improved fitness level, weight loss, improved circumferential anthropometric measures and medication adherence (verified by non-invasive hair analysis. Discussion The novelty of this project comes from two key aspects, complemented with objective information on exercise and medication adherence. The project assesses beliefs about both the underlying goal such as following prescribed treatment; and about the specific behaviours such as undertaking the exercise or taking the medication, using both implicit and explicit assessments of patients’ beliefs and attitudes. We predict that i the way people think about the underlying goal of their treatments explains medication and exercise

  11. Androgen receptor CAG repeat length and TMPRSS2:ETS prostate cancer risk: results From the Prostate Cancer Prevention Trial.

    Science.gov (United States)

    Figg, William D; Chau, Cindy H; Price, Douglas K; Till, Cathee; Goodman, Phyllis J; Cho, Yonggon; Varella-Garcia, Marileila; Reichardt, Juergen K V; Tangen, Catherine M; Leach, Robin J; van Bokhoven, Adrie; Thompson, Ian M; Lucia, M Scott

    2014-07-01

    To investigate the association between the length of the polymorphic trinucleotide CAG microsatellite repeats in exon 1 of the AR gene and the risk of prostate cancer containing TMPRSS2:ETS fusion genes. This nested case-control study came from subjects enrolled in the Prostate Cancer Prevention Trial and included 195 biopsy-proven prostate cancer cases with a known TMPRSS2:ETS status and 1344 matched controls. There was no association between the CAG repeat length and the risk of TMPRSS2:ETS-positive (odds ratio, 0.97; 95% confidence interval, 0.91-1.04) or TMPRSS2:ETS-negative prostate cancer (odds ratio, 1.04; 95% confidence interval, 0.97-1.11) and in patients with low- or high-grade disease. Our findings suggested that AR CAG repeats are not associated with TMPRSS2:ETS formation in prostate cancer. Published by Elsevier Inc.

  12. A Description of Quasar Variability Measured Using Repeated SDSS and POSS Imaging

    CERN Document Server

    MacLeod, Chelsea L; Sesar, Branimir; de Vries, Wim; Kochanek, Christopher S; Kelly, Brandon C; Becker, Andrew C; Lupton, Robert H; Hall, Patrick B; Richards, Gordon T; Anderson, Scott F; Schneider, Donald P

    2011-01-01

    We provide a quantitative description and statistical interpretation of the optical continuum variability of quasars. The Sloan Digital Sky Survey (SDSS) has obtained repeated imaging in five UV-to-IR photometric bands for 34,727 spectroscopically confirmed quasars. About 10,000 quasars have an average of 60 observations in each band obtained over a decade along stripe 82 (S82), whereas the remaining ~25,000 have 2-3 observations due to scan overlaps. The observed time lags span the range from a day to almost 10 years, and constrain quasar variability at rest-frame time lags of up to 4 years, and at rest-frame wavelengths from 1000A to 6000A. We publicly release a user-friendly catalog of quasars from the SDSS Data Release 7 that have been observed at least twice in SDSS or once in both SDSS and the Palomar Observatory Sky Survey, and we use it to analyze the ensemble properties of quasar variability. Based on a damped random walk (DRW) model defined by a characteristic time scale and an asymptotic variabilit...

  13. Magnetic Resonance Spectroscopy in Patients with Insomnia: A Repeated Measurement Study.

    Science.gov (United States)

    Spiegelhalder, Kai; Regen, Wolfram; Nissen, Christoph; Feige, Bernd; Baglioni, Chiara; Riemann, Dieter; Hennig, Jürgen; Lange, Thomas

    2016-01-01

    Chronic insomnia is one of the most prevalent central nervous system disorders. It is characterized by increased arousal levels, however, the neurobiological causes and correlates of hyperarousal in insomnia remain to be further determined. In the current study, magnetic resonance spectroscopy was used in the morning and evening in a well-characterized sample of 20 primary insomnia patients (12 females; 8 males; 42.7 ± 13.4 years) and 20 healthy good sleepers (12 females; 8 males; 44.1 ± 10.6 years). The most important inhibitory and excitatory neurotransmitters of the central nervous system, γ-aminobutyric acid (GABA) and glutamate/glutamine (Glx), were assessed in the anterior cingulate cortex (ACC) and dorsolateral prefrontal cortex (DLPFC). The primary hypothesis, a diurnal effect on GABA levels in patients with insomnia, could not be confirmed. Moreover, the current results did not support previous findings of altered GABA levels in individuals with insomnia. Exploratory analyses, however, suggested that GABA levels in the ACC may be positively associated with habitual sleep duration, and, thus, reduced GABA levels may be a trait marker of objective sleep disturbances. Moreover, there was a significant GROUP x MEASUREMENT TIME interaction effect on Glx in the DLPFC with increasing Glx levels across the day in the patients but not in the control group. Therefore, Glx levels may reflect hyperarousal at bedtime in those with insomnia. Future confirmatory studies should include larger sample sizes to investigate brain metabolites in different subgroups of insomnia.

  14. Estimation of spatial patterns of urban air pollution over a 4-week period from repeated 5-min measurements

    Science.gov (United States)

    Gillespie, Jonathan; Masey, Nicola; Heal, Mathew R.; Hamilton, Scott; Beverland, Iain J.

    2017-02-01

    Determination of intra-urban spatial variations in air pollutant concentrations for exposure assessment requires substantial time and monitoring equipment. The objective of this study was to establish if short-duration measurements of air pollutants can be used to estimate longer-term pollutant concentrations. We compared 5-min measurements of black carbon (BC) and particle number (PN) concentrations made once per week on 5 occasions, with 4 consecutive 1-week average nitrogen dioxide (NO2) concentrations at 18 locations at a range of distances from busy roads in Glasgow, UK. 5-min BC and PN measurements (averaged over the two 5-min periods at the start and end of a week) explained 40-80%, and 7-64% respectively, of spatial variation in the intervening 1-week NO2 concentrations for individual weeks. Adjustment for variations in background concentrations increased the percentage of explained variation in the bivariate relationship between the full set of NO2 and BC measurements over the 4-week period from 28% to 50% prior to averaging of repeat measurements. The averages of five 5-min BC and PN measurements made over 5 weeks explained 75% and 33% respectively of the variation in average 1-week NO2 concentrations over the same period. The relatively high explained variation observed between BC and NO2 measured on different time scales suggests that, with appropriate steps to correct or average out temporal variations, repeated short-term measurements can be used to provide useful information on longer-term spatial patterns for these traffic-related pollutants.

  15. Repeatability and Reproducibility of Retinal Nerve Fiber Layer Parameters Measured by Scanning Laser Polarimetry with Enhanced Corneal Compensation in Normal and Glaucomatous Eyes

    Directory of Open Access Journals (Sweden)

    Mirian Ara

    2015-01-01

    Full Text Available Objective. To assess the intrasession repeatability and intersession reproducibility of peripapillary retinal nerve fiber layer (RNFL thickness parameters measured by scanning laser polarimetry (SLP with enhanced corneal compensation (ECC in healthy and glaucomatous eyes. Methods. One randomly selected eye of 82 healthy individuals and 60 glaucoma subjects was evaluated. Three scans were acquired during the first visit to evaluate intravisit repeatability. A different operator obtained two additional scans within 2 months after the first session to determine intervisit reproducibility. The intraclass correlation coefficient (ICC, coefficient of variation (COV, and test-retest variability (TRT were calculated for all SLP parameters in both groups. Results. ICCs ranged from 0.920 to 0.982 for intravisit measurements and from 0.910 to 0.978 for intervisit measurements. The temporal-superior-nasal-inferior-temporal (TSNIT average was the highest (0.967 and 0.946 in normal eyes, while nerve fiber indicator (NFI; 0.982 and inferior average (0.978 yielded the best ICC in glaucomatous eyes for intravisit and intervisit measurements, respectively. All COVs were under 10% in both groups, except NFI. TSNIT average had the lowest COV (2.43% in either type of measurement. Intervisit TRT ranged from 6.48 to 12.84. Conclusions. The reproducibility of peripapillary RNFL measurements obtained with SLP-ECC was excellent, indicating that SLP-ECC is sufficiently accurate for monitoring glaucoma progression.

  16. Variation in repeated mouth-opening measurements in head and neck cancer patients with and without trismus.

    Science.gov (United States)

    Jager-Wittenaar, H; Dijkstra, P U; Vissink, A; van Oort, R P; Roodenburg, J L N

    2009-01-01

    Trismus after head and neck cancer treatment may severely limit mandibular functioning. Interventions aimed at reducing trismus can only be evaluated when the amount of variation associated with these measurements is known. The aim of this study was to analyse the variation in mouth-opening measurements in patients treated for head and neck cancer, with and without trismus. Maximal mouth opening was measured in 120 patients in two sessions of three repeated measurements by one observer. To analyse the influence of interobserver variation on mouth-opening measurements a subgroup of 30 patients was measured by a second observer. The standard deviation of the six measurements per patient was used as the variation in measurements of maximal mouth opening. No significant difference was found in maximal mouth opening in patients with (n=33) or without (n=87) trismus. The interobserver intraclass correlation coefficient (ICC) was 0.98. Intraobserver ICC and intersession ICC reliabilities both were 0.99. The variation in the mean values of the three measurements was only slightly smaller than the variation of the single measurements. Variation in maximal mouth opening in patients with trismus does not differ from variation in maximal mouth opening in patients without trismus. Interobserver variation is limited.

  17. Thyroid nodules with initially non-diagnostic, fine-needle aspiration results: comparison of core-needle biopsy and repeated fine-needle aspiration.

    Science.gov (United States)

    Choi, Sang Hyun; Baek, Jung Hwan; Lee, Jeong Hyun; Choi, Young Jun; Hong, Min Ji; Song, Dong Eun; Kim, Jae Kyun; Yoon, Jong Ho; Kim, Won Bae

    2014-11-01

    To evaluate the role of core-needle biopsy (CNB) by comparing the results of CNB and repeated fine-needle aspiration (FNA) for thyroid nodules with initially non-diagnostic FNA results. From October 2008 to December 2011, 360 nodules - 180 consecutive repeated FNAs and 180 consecutive CNBs -- from 360 patients (83 men, 277 women; mean age, 54.4 years) with initially non-diagnostic FNA results were analyzed retrospectively. The incidence of non-diagnostic results, inconclusive results, diagnostic surgery, and diagnostic performance of repeated FNA and CNB were assessed, and factors affecting second non-diagnostic results were evaluated. CNB achieved a significantly lower non-diagnostic and inconclusive rate than repeated FNA (1.1 % versus 40.0 %, P needle biopsy achieved a lower number of non-diagnostic and inconclusive results. • Core-needle biopsy achieved better diagnostic performance. • Use of core-needle biopsy could prevent unnecessary diagnostic surgery. • Repeated fine-needle aspiration was significantly associated with a second non-diagnosis.

  18. Repeatability and Reproducibility of Retinal Neuronal and Axonal Measures on Spectral-Domain Optical Coherence Tomography in Patients with Cognitive Impairment

    Directory of Open Access Journals (Sweden)

    Edwin Hong-Teck Loh

    2017-08-01

    Full Text Available BackgroundWith increasing interest in determining if measurement of retinal neuronal structure with spectral-domain optical coherence tomography (SD-OCT is useful in accessing neurodegenerative process in cognitive decline and development of dementia, it is important to evaluate whether the SD-OCT measurements are repeatable and reproducible in these patients.MethodsThis is a retrospective cohort study. Patients with Alzheimer’s disease (AD or mild cognitive impairment (MCI with no change in global clinical dementia rating (CDR score at 1-year follow-up were eligible to be included. Ganglion cell-inner plexiform layer (GC-IPL and retinal nerve fiber layer (RNFL parameters were measured with SD-OCT at baseline, 6-month, and 1-year follow-up visits. At baseline, SD-OCT scans were repeated to access intra-visit repeatability of the SD-OCT measurement. SD-OCT measurement over three visits was used to access inter-visit reproducibility. We calculated intraclass correlation coefficients (ICC and coefficients of variation (CoVs.ResultsWe included 32 patients with stable AD and 29 patients with stable MCI in the final analysis. For GC-IPL measures, the average intra-visit ICC was 0.969 (range: 0.948–0.985, and CoV was 1.81% (range: 1.14–2.40; while the average inter-visit ICC was 0.968 (0.941–0.985, and CoV was 1.91% (range: 1.24–2.32. The average ICC and CoV of intra-visit RNFL measured were 0.965 (range: 0.937–0.986 and 2.32% (range: 1.34–2.90%, respectively. The average ICC and CoV of inter-visit RNFL measures were 0.927 (range: 0.845–0.961 and 3.83% (range: 2.71–5.25%, respectively.ConclusionBoth GC-IPL and RNFL measurements had good intra-visit repeatability and inter-visit reproducibility over 1 year in elderly patients with no decline in cognitive function, suggesting that SD-OCT is a reliable tool to assess neurodegenerative process over time.

  19. A DESCRIPTION OF QUASAR VARIABILITY MEASURED USING REPEATED SDSS AND POSS IMAGING

    Energy Technology Data Exchange (ETDEWEB)

    MacLeod, Chelsea L.; Ivezic, Zeljko; Becker, Andrew C.; Anderson, Scott F. [Department of Astronomy, University of Washington, Box 351580, Seattle, WA 98195 (United States); Sesar, Branimir [Division of Physics, Mathematics and Astronomy, California Institute of Technology, Pasadena, CA 91125 (United States); De Vries, Wim [Department of Physics, University of California, One Shields Ave, Davis, CA 95616 (United States); Kochanek, Christopher S. [Department of Astronomy, Ohio State University, 140 West 18th Avenue, Columbus, OH 43210 (United States); Kelly, Brandon C. [Department of Physics, University of California, Santa Barbara, CA 93106 (United States); Lupton, Robert H. [Department of Astrophysical Sciences, Princeton University, Princeton, New Jersey 08544 (United States); Hall, Patrick B. [Department of Physics and Astronomy, York University, Toronto, ON M3J 1P3 (Canada); Richards, Gordon T. [Department of Physics, Drexel University, 3141 Chestnut Street, Philadelphia, PA 19104 (United States); Schneider, Donald P. [Department of Astronomy and Astrophysics, Pennsylvania State University, 525 Davey Laboratory, University Park, PA 16802 (United States)

    2012-07-10

    We provide a quantitative description and statistical interpretation of the optical continuum variability of quasars. The Sloan Digital Sky Survey (SDSS) has obtained repeated imaging in five UV-to-IR photometric bands for 33,881 spectroscopically confirmed quasars. About 10,000 quasars have an average of 60 observations in each band obtained over a decade along Stripe 82 (S82), whereas the remaining {approx}25,000 have 2-3 observations due to scan overlaps. The observed time lags span the range from a day to almost 10 years, and constrain quasar variability at rest-frame time lags of up to 4 years, and at rest-frame wavelengths from 1000 A to 6000 A. We publicly release a user-friendly catalog of quasars from the SDSS Data Release 7 that have been observed at least twice in SDSS or once in both SDSS and the Palomar Observatory Sky Survey, and we use it to analyze the ensemble properties of quasar variability. Based on a damped random walk (DRW) model defined by a characteristic timescale and an asymptotic variability amplitude that scale with the luminosity, black hole mass, and rest wavelength for individual quasars calibrated in S82, we can fully explain the ensemble variability statistics of the non-S82 quasars such as the exponential distribution of large magnitude changes. All available data are consistent with the DRW model as a viable description of the optical continuum variability of quasars on timescales of {approx}5-2000 days in the rest frame. We use these models to predict the incidence of quasar contamination in transient surveys such as those from the Palomar Transient Factory and Large Synoptic Survey Telescope.

  20. Breath acidification in adolescent runners exposed to atmospheric pollution: A prospective, repeated measures observational study

    Directory of Open Access Journals (Sweden)

    Van Sickle David

    2008-03-01

    Full Text Available Abstract Background Vigorous outdoors exercise during an episode of air pollution might cause airway inflammation. The purpose of this study was to examine the effects of vigorous outdoor exercise during peak smog season on breath pH, a biomarker of airway inflammation, in adolescent athletes. Methods We measured breath pH both pre- and post-exercise on ten days during peak smog season in 16 high school athletes engaged in daily long-distance running in a downwind suburb of Atlanta. The association of post-exercise breath pH with ambient ozone and particulate matter concentrations was tested with linear regression. Results We collected 144 pre-exercise and 146 post-exercise breath samples from 16 runners (mean age 14.9 years, 56% male. Median pre-exercise breath pH was 7.58 (interquartile range: 6.90 to 7.86 and did not change significantly after exercise. We observed no significant association between ambient ozone or particulate matter and post-exercise breath pH. However both pre- and post-exercise breath pH were strikingly low in these athletes when compared to a control sample of 14 relatively sedentary healthy adults and to published values of breath pH in healthy subjects. Conclusion Although we did not observe an acute effect of air pollution exposure during exercise on breath pH, breath pH was surprisingly low in this sample of otherwise healthy long-distance runners. We speculate that repetitive vigorous exercise may induce airway acidification.

  1. A review of the reporting and handling of missing data in cohort studies with repeated assessment of exposure measures

    Directory of Open Access Journals (Sweden)

    Karahalios Amalia

    2012-07-01

    Full Text Available Abstract Background Retaining participants in cohort studies with multiple follow-up waves is difficult. Commonly, researchers are faced with the problem of missing data, which may introduce biased results as well as a loss of statistical power and precision. The STROBE guidelines von Elm et al. (Lancet, 370:1453-1457, 2007; Vandenbroucke et al. (PLoS Med, 4:e297, 2007 and the guidelines proposed by Sterne et al. (BMJ, 338:b2393, 2009 recommend that cohort studies report on the amount of missing data, the reasons for non-participation and non-response, and the method used to handle missing data in the analyses. We have conducted a review of publications from cohort studies in order to document the reporting of missing data for exposure measures and to describe the statistical methods used to account for the missing data. Methods A systematic search of English language papers published from January 2000 to December 2009 was carried out in PubMed. Prospective cohort studies with a sample size greater than 1,000 that analysed data using repeated measures of exposure were included. Results Among the 82 papers meeting the inclusion criteria, only 35 (43% reported the amount of missing data according to the suggested guidelines. Sixty-eight papers (83% described how they dealt with missing data in the analysis. Most of the papers excluded participants with missing data and performed a complete-case analysis (n = 54, 66%. Other papers used more sophisticated methods including multiple imputation (n = 5 or fully Bayesian modeling (n = 1. Methods known to produce biased results were also used, for example, Last Observation Carried Forward (n = 7, the missing indicator method (n = 1, and mean value substitution (n = 3. For the remaining 14 papers, the method used to handle missing data in the analysis was not stated. Conclusions This review highlights the inconsistent reporting of missing data in cohort studies and the continuing

  2. A theory-based online health behaviour intervention for new university students (U@Uni:LifeGuide): results from a repeat randomized controlled trial.

    Science.gov (United States)

    Cameron, David; Epton, Tracy; Norman, Paul; Sheeran, Paschal; Harris, Peter R; Webb, Thomas L; Julious, Steven A; Brennan, Alan; Thomas, Chloe; Petroczi, Andrea; Naughton, Declan; Shah, Iltaf

    2015-12-07

    This paper reports the results of a repeat trial assessing the effectiveness of an online theory-based intervention to promote healthy lifestyle behaviours in new university students. The original trial found that the intervention reduced the number of smokers at 6-month follow-up compared with the control condition, but had non-significant effects on the other targeted health behaviours. However, the original trial suffered from low levels of engagement, which the repeat trial sought to rectify. Three weeks before staring university, all incoming undergraduate students at a large university in the UK were sent an email inviting them to participate in the study. After completing a baseline questionnaire, participants were randomly allocated to intervention or control conditions. The intervention consisted of a self-affirmation manipulation, health messages based on the theory of planned behaviour and implementation intention tasks. Participants were followed-up 1 and 6 months after starting university. The primary outcome measures were portions of fruit and vegetables consumed, physical activity levels, units of alcohol consumed and smoking status at 6-month follow-up. The study recruited 2,621 students (intervention n=1346, control n=1275), of whom 1495 completed at least one follow-up (intervention n=696, control n=799). Intention-to-treat analyses indicated that the intervention had a non-significant effect on the primary outcomes, although the effect of the intervention on fruit and vegetable intake was significant in the per-protocol analyses. Secondary analyses revealed that the intervention had significant effects on having smoked at university (self-report) and on a biochemical marker of alcohol use. Despite successfully increasing levels of engagement, the intervention did not have a significant effect on the primary outcome measures. The relatively weak effects of the intervention, found in both the original and repeat trials, may be due to the focus on

  3. Detecting variable responses in time-series using repeated measures ANOVA: Application to physiologic challenges [version 2; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Paul M. Macey

    2016-07-01

    Full Text Available We present an approach to analyzing physiologic timetrends recorded during a stimulus by comparing means at each time point using repeated measures analysis of variance (RMANOVA. The approach allows temporal patterns to be examined without an a priori model of expected timing or pattern of response. The approach was originally applied to signals recorded from functional magnetic resonance imaging (fMRI volumes-of-interest (VOI during a physiologic challenge, but we have used the same technique to analyze continuous recordings of other physiological signals such as heart rate, breathing rate, and pulse oximetry. For fMRI, the method serves as a complement to whole-brain voxel-based analyses, and is useful for detecting complex responses within pre-determined brain regions, or as a post-hoc analysis of regions of interest identified by whole-brain assessments. We illustrate an implementation of the technique in the statistical software packages R and SAS. VOI timetrends are extracted from conventionally preprocessed fMRI images. A timetrend of average signal intensity across the VOI during the scanning period is calculated for each subject. The values are scaled relative to baseline periods, and time points are binned. In SAS, the procedure PROC MIXED implements the RMANOVA in a single step. In R, we present one option for implementing RMANOVA with the mixed model function “lme”. Model diagnostics, and predicted means and differences are best performed with additional libraries and commands in R; we present one example. The ensuing results allow determination of significant overall effects, and time-point specific within- and between-group responses relative to baseline. We illustrate the technique using fMRI data from two groups of subjects who underwent a respiratory challenge. RMANOVA allows insight into the timing of responses and response differences between groups, and so is suited to physiologic testing paradigms eliciting complex

  4. Repeatability of Cone Spacing Measures in Eyes With Inherited Retinal Degenerations

    National Research Council Canada - National Science Library

    Zayit-Soudry, Shiri; Sippl-Swezey, Nicolas; Porco, Travis C; Lynch, Stephanie K; Syed, Reema; Ratnam, Kavitha; Menghini, Moreno; Roorda, Austin J; Duncan, Jacque L

    2015-01-01

    ...)-derived cone spacing measures in eyes with inherited retinal degenerations (IRD) and in normal eyes. Twenty IRD patients and 10 visually normal subjects underwent AOSLO imaging at two visits separated by no more than 1 month...

  5. Repeatability of Choroidal Thickness Measurements on Enhanced Depth Imaging Optical Coherence Tomography Using Different Posterior Boundaries.

    Science.gov (United States)

    Vuong, Vivian S; Moisseiev, Elad; Cunefare, David; Farsiu, Sina; Moshiri, Ala; Yiu, Glenn

    2016-09-01

    To assess the reliability of manual choroidal thickness measurements by comparing different posterior boundary definitions of the choroidal-scleral junction on enhanced depth imaging optical coherence tomography (EDI-OCT). Reliability analysis. Two graders marked the choroidal-scleral junction with segmentation software using different posterior boundaries: (1) the outer border of the choroidal vessel lumen, (2) the outer border of the choroid stroma, and (3) the inner border of the sclera, to measure the vascular choroidal thickness (VCT), stromal choroidal thickness (SCT), and total choroidal thickness (TCT), respectively. Measurements were taken at 0.5-mm intervals from 1.5 mm nasal to 1.5 mm temporal to the fovea, and averaged continuously across the central 3 mm of the macula. Intraclass correlation coefficient (ICC) and coefficient of reliability (CR) were compared to assess intergrader and intragrader reliability. Choroidal thickness measurements varied significantly with different posterior boundaries (P choroidal-scleral junction visibility was Choroidal thickness measurements are more reproducible when measured to the border of the choroid stroma (SCT) than the vascular lumen (VCT) or sclera (TCT). Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Predictors and Variability of Repeat Measurements of Urinary Phenols and Parabens in a Cohort of Shanghai Women and Men

    Science.gov (United States)

    Buckley, Jessie P.; Yang, Gong; Liao, Linda M.; Satagopan, Jaya; Calafat, Antonia M.; Matthews, Charles E.; Cai, Qiuyin; Ji, Bu-Tian; Cai, Hui; Wolff, Mary S.; Rothman, Nathaniel; Zheng, Wei; Xiang, Yong-Bing; Shu, Xiao-Ou; Gao, Yu-Tang; Chow, Wong-Ho

    2014-01-01

    Background: Exposure to certain phenols is ubiquitous because of their use in many consumer and personal care products. However, predictors of exposure have not been well characterized in most populations. Objectives: We sought to identify predictors of exposure and to assess the reproducibility of phenol concentrations across serial spot urine samples among Chinese adults. Methods: We measured 2,4-dichlorophenol, 2,5-dichlorophenol, butyl paraben, methyl paraben, propyl paraben, benzophenone-3, bisphenol A, and triclosan in urine collected during 1997–2006 from 50 participants of the Shanghai Women’s Health Study cohort and during 2002–2006 from 50 participants of the Shanghai Men’s Health Study cohort. We investigated predictors of concentrations using the Satterthwaite t-test, and assessed reproducibility among serial samples using intraclass correlation coefficients (ICCs) and Spearman correlation coefficients (SCCs). Results: Creatinine-corrected phenol concentrations were generally higher among women than men. Participants who had taken medicine within the previous 24 hr had higher concentrations of propyl paraben. Cigarette smoking was associated with lower concentrations of propyl and methyl parabens among men. Bottled water consumption was associated with higher bisphenol A, 2,4-dichlorophenol, and 2,5-dichlorophenol concentrations among women. Among men, reproducibility across serial samples was moderate for 2,4-dichlorophenol and 2,5-dichlorophenol (ICC = 0.54–0.60, SCC = 0.43–0.56), but lower for other analytes (ICC = 0.20–0.29). Reproducibility among women was low (ICC = 0.13–0.39), but increased when restricted to morning-only urine samples. Conclusions: Among these 100 Shanghai residents, urinary phenol concentrations varied by sex, smoking, and consumption of bottled water. Our results suggest that a single urine sample may be adequate for ranking exposure to the precursors of 2,4-dichlorophenol and 2,5-dichlorophenol among men and

  7. A review of the reporting and handling of missing data in cohort studies with repeated assessment of exposure measures.

    Science.gov (United States)

    Karahalios, Amalia; Baglietto, Laura; Carlin, John B; English, Dallas R; Simpson, Julie A

    2012-07-11

    Retaining participants in cohort studies with multiple follow-up waves is difficult. Commonly, researchers are faced with the problem of missing data, which may introduce biased results as well as a loss of statistical power and precision. The STROBE guidelines von Elm et al. (Lancet, 370:1453-1457, 2007); Vandenbroucke et al. (PLoS Med, 4:e297, 2007) and the guidelines proposed by Sterne et al. (BMJ, 338:b2393, 2009) recommend that cohort studies report on the amount of missing data, the reasons for non-participation and non-response, and the method used to handle missing data in the analyses. We have conducted a review of publications from cohort studies in order to document the reporting of missing data for exposure measures and to describe the statistical methods used to account for the missing data. A systematic search of English language papers published from January 2000 to December 2009 was carried out in PubMed. Prospective cohort studies with a sample size greater than 1,000 that analysed data using repeated measures of exposure were included. Among the 82 papers meeting the inclusion criteria, only 35 (43%) reported the amount of missing data according to the suggested guidelines. Sixty-eight papers (83%) described how they dealt with missing data in the analysis. Most of the papers excluded participants with missing data and performed a complete-case analysis (n=54, 66%). Other papers used more sophisticated methods including multiple imputation (n=5) or fully Bayesian modeling (n=1). Methods known to produce biased results were also used, for example, Last Observation Carried Forward (n=7), the missing indicator method (n=1), and mean value substitution (n=3). For the remaining 14 papers, the method used to handle missing data in the analysis was not stated. This review highlights the inconsistent reporting of missing data in cohort studies and the continuing use of inappropriate methods to handle missing data in the analysis. Epidemiological journals

  8. Repeatability of measurements: Non-Hermitian observables and quantum Coriolis force

    Science.gov (United States)

    Gardas, Bartłomiej; Deffner, Sebastian; Saxena, Avadh

    2016-08-01

    A noncommuting measurement transfers, via the apparatus, information encoded in a system's state to the external "observer." Classical measurements determine properties of physical objects. In the quantum realm, the very same notion restricts the recording process to orthogonal states as only those are distinguishable by measurements. Therefore, even a possibility to describe physical reality by means of non-Hermitian operators should volens nolens be excluded as their eigenstates are not orthogonal. Here, we show that non-Hermitian operators with real spectra can be treated within the standard framework of quantum mechanics. Furthermore, we propose a quantum canonical transformation that maps Hermitian systems onto non-Hermitian ones. Similar to classical inertial forces this map is accompanied by an energetic cost, pinning the system on the unitary path.

  9. Mediation of the Relationship between Maternal Phthalate Exposure and Preterm Birth by Oxidative Stress with Repeated Measurements across Pregnancy.

    Science.gov (United States)

    Ferguson, Kelly K; Chen, Yin-Hsiu; VanderWeele, Tyler J; McElrath, Thomas F; Meeker, John D; Mukherjee, Bhramar

    2017-03-01

    Mediation analysis is useful for understanding mechanisms and has been used minimally in the study of the environment and disease. We examined mediation of the association between phthalate exposure during pregnancy and preterm birth by oxidative stress. This nested case-control study of preterm birth (n = 130 cases, 352 controls) included women who delivered in Boston, Massachusestts, from 2006 through 2008. Phthalate metabolites and 8-isoprostane, an oxidative stress biomarker, were measured in urine from three visits in pregnancy. We applied four counterfactual mediation methods: method 1, utilizing exposure and mediator averages; method 2, using averages but allowing for an exposure-mediator interaction; method 3, incorporating longitudinal measurements of the exposure and mediator; and method 4, using longitudinal measurements and allowing for an exposure-mediator interaction. We observed mediation of the associations between phthalate metabolites and all preterm birth by 8-isoprostane, with the greatest estimated proportion mediated observed for spontaneous preterm births specifically. Fully utilizing repeated measures of the exposure and mediator improved precision of indirect (i.e., mediated) effect estimates, and including an exposure-mediator interaction increased the estimated proportion mediated. For example, for mono(2-ethyl-carboxy-propyl) phthalate (MECPP), a metabolite of di(2-ethylhexyl) phthalate (DEHP), the percent of the total effect mediated by 8-isoprostane increased from 47% to 60% with inclusion of an exposure-mediator interaction term, in reference to a total adjusted odds ratio of 1.67 or 1.48, respectively. This demonstrates mediation of the phthalate-preterm birth relationship by oxidative stress, and the utility of complex regression models in capturing mediated associations when repeated measures of exposure and mediator are available and an exposure-mediator interaction may exist. Citation: Ferguson KK, Chen YH, VanderWeele TJ, Mc

  10. Repeatability of Brain Volume Measurements Made with the Atlas-based Method from T1-weighted Images Acquired Using a 0.4 Tesla Low Field MR Scanner.

    Science.gov (United States)

    Goto, Masami; Suzuki, Makoto; Mizukami, Shinya; Abe, Osamu; Aoki, Shigeki; Miyati, Tosiaki; Fukuda, Michinari; Gomi, Tsutomu; Takeda, Tohoru

    2016-10-11

    An understanding of the repeatability of measured results is important for both the atlas-based and voxel-based morphometry (VBM) methods of magnetic resonance (MR) brain volumetry. However, many recent studies that have investigated the repeatability of brain volume measurements have been performed using static magnetic fields of 1-4 tesla, and no study has used a low-strength static magnetic field. The aim of this study was to investigate the repeatability of measured volumes using the atlas-based method and a low-strength static magnetic field (0.4 tesla). Ten healthy volunteers participated in this study. Using a 0.4 tesla magnetic resonance imaging (MRI) scanner and a quadrature head coil, three-dimensional T1-weighted images (3D-T1WIs) were obtained from each subject, twice on the same day. VBM8 software was used to construct segmented normalized images [gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF) images]. The regions-of-interest (ROIs) of GM, WM, CSF, hippocampus (HC), orbital gyrus (OG), and cerebellum posterior lobe (CPL) were generated using WFU PickAtlas. The percentage change was defined as[100 × (measured volume with first segmented image - mean volume in each subject)/(mean volume in each subject)]The average percentage change was calculated as the percentage change in the 6 ROIs of the 10 subjects. The mean of the average percentage changes for each ROI was as follows: GM, 0.556%; WM, 0.324%; CSF, 0.573%; HC, 0.645%; OG, 1.74%; and CPL, 0.471%. The average percentage change was higher for the orbital gyrus than for the other ROIs. We consider that repeatability of the atlas-based method is similar between 0.4 and 1.5 tesla MR scanners. To our knowledge, this is the first report to show that the level of repeatability with a 0.4 tesla MR scanner is adequate for the estimation of brain volume change by the atlas-based method.

  11. Eigenfactor : Does the Principle of Repeated Improvement Result in Better Journal Impact Estimates than Raw Citation Counts?

    CERN Document Server

    Davis, Philip M

    2008-01-01

    Eigenfactor.org, a journal evaluation tool which uses an iterative algorithm to weight citations (similar to the PageRank algorithm used for Google) has been proposed as a more valid method for calculating the impact of journals. The purpose of this brief communication is to investigate whether the principle of repeated improvement provides different rankings of journals than does a simple unweighted citation count (the method used by ISI).

  12. An L-band SAR for repeat pass deformation measurements on a UAV platform

    Science.gov (United States)

    Wheeler, Kevin; Hensley, Scott; Lou, Yunling

    2004-01-01

    We are proposing to develop a miniaturized polarimetric L-band synthetic aperture radar (SAR) for repeatpass differential interferometric measurements of deformation for rapidly deforming surfaces of geophysical interest such as volcanoes or earthquakes that is to be flown on a unmanned aerial vehicle (UAV or minimally piloted vehicle (MPV).

  13. Repeated measurements of P retention in ponies fed rations with various Ca:P ratios

    NARCIS (Netherlands)

    van Doorn, D A; Schaafstra, F J W C; Wouterse, H; Everts, H; Estepa, J C; Aguilera-Tejero, E; Beynen, A C

    2014-01-01

    This study addresses the question of whether feeding rations rich in P for a period of up to 42 d induces a positive P balance in adult ponies. Biochemical bone markers and parathyroid hormone (PTH; intact as well as whole PTH) were measured to obtain clues as to the effect of P loading on bone meta

  14. Alterations in Whole-Body Insulin Sensitivity Resulting From Repeated Eccentric Exercise of a Single Muscle Group: A Pilot Investigation.

    Science.gov (United States)

    Gonzalez, Javier T; Barwood, Martin J; Goodall, Stuart; Thomas, Kevin; Howatson, Glyn

    2015-08-01

    Unaccustomed eccentric exercise using large muscle groups elicits soreness, decrements in physical function and impairs markers of whole-body insulin sensitivity; although these effects are attenuated with a repeated exposure. Eccentric exercise of a small muscle group (elbow flexors) displays similar soreness and damage profiles in response to repeated exposure. However, it is unknown whether damage to small muscle groups impacts upon whole-body insulin sensitivity. This pilot investigation aimed to characterize whole-body insulin sensitivity in response to repeated bouts of eccentric exercise of the elbow flexors. Nine healthy males completed two bouts of eccentric exercise separated by 2 weeks. Insulin resistance (updated homeostasis model of insulin resistance, HOMA2-IR) and muscle damage profiles (soreness and physical function) were assessed before, and 48 h after exercise. Matsuda insulin sensitivity indices (ISI Matsuda) were also determined in 6 participants at the same time points as HOMA2-IR. Soreness was elevated, and physical function impaired, by both bouts of exercise (both p Eccentric exercise decreased ISI Matsuda after the first but not the second bout of eccentric exercise (time x bout interaction p Eccentric exercise performed with an isolated upper limb impairs whole-body insulin sensitivity after the first, but not the second, bout.

  15. Repeated measures of urinary oxidative stress biomarkers during pregnancy and preterm birth.

    Science.gov (United States)

    Ferguson, Kelly K; McElrath, Thomas F; Chen, Yin-Hsiu; Loch-Caruso, Rita; Mukherjee, Bhramar; Meeker, John D

    2015-02-01

    The purpose of this study was to investigate oxidative stress as a mechanism of preterm birth in human subjects; we examined associations between urinary biomarkers of oxidative stress that were measured at multiple time points during pregnancy and preterm birth. This nested case-control study included 130 mothers who delivered preterm and 352 mothers who delivered term who were originally recruited as part of an ongoing prospective birth cohort at Brigham and Women's Hospital. Two biomarkers that included 8-hydroxydeoxyguanosine (8-OHdG) and 8-isoprostane were measured in urine samples that were collected at up to 4 time points (median 10, 18, 26, and 35 weeks) during gestation. Urinary concentrations of 8-isoprostane and 8-OHdG decreased and increased, respectively, as pregnancy progressed. Average levels of 8-isoprostane across pregnancy were associated with increased odds of spontaneous preterm birth (adjusted odds ratio, 6.25; 95% confidence interval, 2.86-13.7), and associations were strongest with levels measured later in pregnancy. Average levels of 8-OHdG were protective against overall preterm birth (adjusted odds ratio, 0.19; 95% confidence interval, 0.10-0.34), and there were no apparent differences in the protective effect in cases of spontaneous preterm birth compared with cases of placental origin. Odds ratios for overall preterm birth were more protective in association with urinary 8-OHdG concentrations that were measured early in pregnancy. Maternal oxidative stress may be an important contributor to preterm birth, regardless of subtype and timing of exposure during pregnancy. The 2 biomarkers that were measured in the present study had opposite associations with preterm birth; an improved understanding of what each represents may help to identify more precisely important mechanisms in the pathway to preterm birth. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Characterization of fetal growth by repeated ultrasound measurements in the wild guinea pig (Cavia aperea).

    Science.gov (United States)

    Schumann, K; Guenther, A; Göritz, F; Jewgenow, K

    2014-08-01

    Fetal growth during pregnancy has previously been studied in the domesticated guinea pig (Cavia aperea f. porcellus) after dissecting pregnant females, but there are no studies describing the fetal growth in their wild progenitor, the wild guinea pig (C aperea). In this study, 50 pregnancies of wild guinea pig sows were investigated using modern ultrasound technique. The two most common fetal growth parameters (biparietal diameter [BPD] and crown-rump-length [CRL]) and uterine position were measured. Data revealed similar fetal growth patterns in the wild guinea pig and domesticated guinea pig in the investigated gestation period, although they differ in reproductive milestones such as gestation length (average duration of pregnancy 68 days), average birth weight, and litter mass. In this study, pregnancy lasted on average 60.2 days with a variance of less than a day (0.96 days). The measured fetal growth parameters are strongly correlated with each (R = 0.91; P guinea pig.

  17. Reliability of plasma lipopolysaccharide-binding protein (LBP) from repeated measures in healthy adults.

    Science.gov (United States)

    Citronberg, Jessica S; Wilkens, Lynne R; Lim, Unhee; Hullar, Meredith A J; White, Emily; Newcomb, Polly A; Le Marchand, Loïc; Lampe, Johanna W

    2016-09-01

    Plasma lipopolysaccharide-binding protein (LBP), a measure of internal exposure to bacterial lipopolysaccharide, has been associated with several chronic conditions and may be a marker of chronic inflammation; however, no studies have examined the reliability of this biomarker in a healthy population. We examined the temporal reliability of LBP measured in archived samples from participants in two studies. In Study one, 60 healthy participants had blood drawn at two time points: baseline and follow-up (either three, six, or nine months). In Study two, 24 individuals had blood drawn three to four times over a seven-month period. We measured LBP in archived plasma by ELISA. Test-retest reliability was estimated by calculating the intraclass correlation coefficient (ICC). Plasma LBP concentrations showed moderate reliability in Study one (ICC 0.60, 95 % CI 0.43-0.75) and Study two (ICC 0.46, 95 % CI 0.26-0.69). Restricting the follow-up period improved reliability. In Study one, the reliability of LBP over a three-month period was 0.68 (95 % CI: 0.41-0.87). In Study two, the ICC of samples taken ≤seven days apart was 0.61 (95 % CI 0.29-0.86). Plasma LBP concentrations demonstrated moderate test-retest reliability in healthy individuals with reliability improving over a shorter follow-up period.

  18. Global sensitivity analysis for repeated measures studies with informative drop-out: A semi-parametric approach.

    Science.gov (United States)

    Scharfstein, Daniel; McDermott, Aidan; Díaz, Iván; Carone, Marco; Lunardon, Nicola; Turkoz, Ibrahim

    2017-05-23

    In practice, both testable and untestable assumptions are generally required to draw inference about the mean outcome measured at the final scheduled visit in a repeated measures study with drop-out. Scharfstein et al. (2014) proposed a sensitivity analysis methodology to determine the robustness of conclusions within a class of untestable assumptions. In their approach, the untestable and testable assumptions were guaranteed to be compatible; their testable assumptions were based on a fully parametric model for the distribution of the observable data. While convenient, these parametric assumptions have proven especially restrictive in empirical research. Here, we relax their distributional assumptions and provide a more flexible, semi-parametric approach. We illustrate our proposal in the context of a randomized trial for evaluating a treatment of schizoaffective disorder. © 2017, The International Biometric Society.

  19. All-photonic quantum repeaters

    Science.gov (United States)

    Azuma, Koji; Tamaki, Kiyoshi; Lo, Hoi-Kwong

    2015-01-01

    Quantum communication holds promise for unconditionally secure transmission of secret messages and faithful transfer of unknown quantum states. Photons appear to be the medium of choice for quantum communication. Owing to photon losses, robust quantum communication over long lossy channels requires quantum repeaters. It is widely believed that a necessary and highly demanding requirement for quantum repeaters is the existence of matter quantum memories. Here we show that such a requirement is, in fact, unnecessary by introducing the concept of all-photonic quantum repeaters based on flying qubits. In particular, we present a protocol based on photonic cluster-state machine guns and a loss-tolerant measurement equipped with local high-speed active feedforwards. We show that, with such all-photonic quantum repeaters, the communication efficiency scales polynomially with the channel distance. Our result paves a new route towards quantum repeaters with efficient single-photon sources rather than matter quantum memories. PMID:25873153

  20. Fixed-flexion knee radiography using a new positioning device produced highly repeatable measurements of joint space width: ELSA-Brasil Musculoskeletal Study (ELSA-Brasil MSK).

    Science.gov (United States)

    Telles, Rosa Weiss; Costa-Silva, Luciana; Machado, Luciana A C; Reis, Rodrigo Citton Padilha Dos; Barreto, Sandhi Maria

    To describe the performance of a non-fluoroscopic fixed-flexion PA radiographic protocol with a new positioning device, developed for the assessment of knee osteoarthritis (OA) in Brazilian Longitudinal Study of Adult Health Musculoskeletal Study (ELSA-Brasil MSK). A test-retest design including 19 adults (38 knee images) was conducted. Feasibility of the radiographic protocol was assessed by image quality parameters and presence of radioanatomic alignment according to intermargin distance (IMD) values. Repeatability was assessed for IMD and joint space width (JSW) measured at three different locations. Approximately 90% of knee images presented excellent quality. Frequencies of nearly perfect radioanatomic alignment (IMD ≤1mm) ranged from 29% to 50%, and satisfactory alignment was found in up to 71% and 76% of the images (IMD ≤1.5mm and ≤1.7mm, respectively). Repeatability analyses yielded the following results: IMD [SD of mean difference=1.08; coefficient of variation (%CV)=54.68%; intraclass correlation coefficient (ICC) (95%CI)=0.59 (0.34-0.77)]; JSW [SD of mean difference=0.34-0.61; %CV=4.48%-9.80%; ICC (95%CI)=0.74 (0.55-0.85)-0.94 (0.87-0.97)]. Adequately reproducible measurements of IMD and JSW were found in 68% and 87% of the images, respectively. Despite the difficulty in achieving consistent radioanatomic alignment between subsequent radiographs in terms of IMD, the protocol produced highly repeatable JSW measurements when these were taken at midpoint and 10mm from the medial extremity of the medial tibial plateau. Therefore, measurements of JSW at these locations can be considered adequate for the assessment of knee OA in ELSA-Brasil MSK. Copyright © 2016. Published by Elsevier Editora Ltda.

  1. Repeated serum creatinine measurement in primary care: Not all patients have chronic renal failure.

    Science.gov (United States)

    Gentille Lorente, Delicia; Gentille Lorente, Jorge; Salvadó Usach, Teresa

    2015-01-01

    To assess the prevalence of kidney failure in patients from a primary care centre in a basic healthcare district with laboratory availability allowing serum creatinine measurements. An observational descriptive cross-sectional study. A basic healthcare district serving 23,807 people aged ≥ 18 years. Prevalence of kidney failure among 17,240 patients having at least one laboratory measurement available was 8.5% (mean age 77.6 ± 12.05 years). In 33.2% of such patients an occult kidney failure was found (98.8% were women). Prevalence of chronic kidney failure among 10,011 patients having at least 2 laboratory measurements available (≥ 3 months apart) was 5.5% with mean age being 80.1 ± 10.0 years (most severely affected patients were those aged 75 to 84); 59.7% were men and 76.3% of cases were in stage 3. An occult kidney failure was found in 5.3% of patients with women being 86.2% of them (a glomerular filtration rate<60 ml/min was estimated for plasma creatinine levels of 0.9 mg/dl or higher). Comparison of present findings to those previously reported demonstrates the need for further studies on the prevalence of overall (chronic and acute) kidney failure in Spain in order to estimate the real scope of the disease. Primary care physicians play a critical role in disease detection, therapy, control and recording (in medical records). MDRD equation is useful and practical to estimate glomerular filtration rate. Copyright © 2015 The Authors. Published by Elsevier España, S.L.U. All rights reserved.

  2. Assessment of individual agreements with repeated measurements based on generalized confidence intervals.

    Science.gov (United States)

    Quiroz, Jorge; Burdick, Richard K

    2009-01-01

    Individual agreement between two measurement systems is determined using the total deviation index (TDI) or the coverage probability (CP) criteria as proposed by Lin (2000) and Lin et al. (2002). We used a variance component model as proposed by Choudhary (2007). Using the bootstrap approach, Choudhary (2007), and generalized confidence intervals, we construct bounds on TDI and CP. A simulation study was conducted to assess whether the bounds maintain the stated type I error probability of the test. We also present a computational example to demonstrate the statistical methods described in the paper.

  3. Prediction Accuracy in Multivariate Repeated-Measures Bayesian Forecasting Models with Examples Drawn from Research on Sleep and Circadian Rhythms

    Directory of Open Access Journals (Sweden)

    Clark Kogan

    2016-01-01

    Full Text Available In study designs with repeated measures for multiple subjects, population models capturing within- and between-subjects variances enable efficient individualized prediction of outcome measures (response variables by incorporating individuals response data through Bayesian forecasting. When measurement constraints preclude reasonable levels of prediction accuracy, additional (secondary response variables measured alongside the primary response may help to increase prediction accuracy. We investigate this for the case of substantial between-subjects correlation between primary and secondary response variables, assuming negligible within-subjects correlation. We show how to determine the accuracy of primary response predictions as a function of secondary response observations. Given measurement costs for primary and secondary variables, we determine the number of observations that produces, with minimal cost, a fixed average prediction accuracy for a model of subject means. We illustrate this with estimation of subject-specific sleep parameters using polysomnography and wrist actigraphy. We also consider prediction accuracy in an example time-dependent, linear model and derive equations for the optimal timing of measurements to achieve, on average, the best prediction accuracy. Finally, we examine an example involving a circadian rhythm model and show numerically that secondary variables can improve individualized predictions in this time-dependent nonlinear model as well.

  4. Prediction Accuracy in Multivariate Repeated-Measures Bayesian Forecasting Models with Examples Drawn from Research on Sleep and Circadian Rhythms.

    Science.gov (United States)

    Kogan, Clark; Kalachev, Leonid; Van Dongen, Hans P A

    2016-01-01

    In study designs with repeated measures for multiple subjects, population models capturing within- and between-subjects variances enable efficient individualized prediction of outcome measures (response variables) by incorporating individuals response data through Bayesian forecasting. When measurement constraints preclude reasonable levels of prediction accuracy, additional (secondary) response variables measured alongside the primary response may help to increase prediction accuracy. We investigate this for the case of substantial between-subjects correlation between primary and secondary response variables, assuming negligible within-subjects correlation. We show how to determine the accuracy of primary response predictions as a function of secondary response observations. Given measurement costs for primary and secondary variables, we determine the number of observations that produces, with minimal cost, a fixed average prediction accuracy for a model of subject means. We illustrate this with estimation of subject-specific sleep parameters using polysomnography and wrist actigraphy. We also consider prediction accuracy in an example time-dependent, linear model and derive equations for the optimal timing of measurements to achieve, on average, the best prediction accuracy. Finally, we examine an example involving a circadian rhythm model and show numerically that secondary variables can improve individualized predictions in this time-dependent nonlinear model as well.

  5. The clinical applicability of a daily summary of patients' self-reported postoperative pain-A repeated measure analysis.

    Science.gov (United States)

    Wikström, Lotta; Eriksson, Kerstin; Fridlund, Bengt; Nilsson, Mats; Årestedt, Kristofer; Broström, Anders

    2017-03-23

    (i) To determine whether a central tendency, median, based on patients' self-rated pain is a clinically applicable daily measure to show patients' postoperative pain on the first day after major surgery (ii) and to determine the number of self-ratings required for the calculation of this measure. Perioperative pain traits in medical records are difficult to overview. The clinical applicability of a daily documented summarising measure of patients' self-rated pain scores is little explored. A repeated measure design was carried out at three Swedish country hospitals. Associations between the measures were analysed with nonparametric statistical methods; systematic and individual group changes were analysed separately. Measure I: pain scores at rest and activity postoperative day 1; measure II: retrospective average pain from postoperative day 1. The sample consisted of 190 general surgery patients and 289 orthopaedic surgery patients with a mean age of 65; 56% were men. Forty-four percent had a pre-operative daily intake of analgesia, and 77% used postoperative opioids. A range of 4-9 pain scores seem to be eligible for the calculation of the daily measures of pain. Rank correlations for individual median scores, based on four ratings, vs. retrospective self-rated average pain, were moderate and strengthened with increased numbers of ratings. A systematic group change towards a higher level of reported retrospective pain was significant. The median values were clinically applicable daily measures. The risk of obtaining a higher value than was recalled by patients seemed to be low. Applicability increased with increased frequency of self-rated pain scores and with high-quality pain assessments. The documenting of daily median pain scores at rest and during activity could constitute the basis for obtaining patients' experiences by showing their pain severity trajectories. The measures could also be an important key to predicting postoperative health

  6. Repeated measures of inflammation and oxidative stress biomarkers in preeclamptic and normotensive pregnancies.

    Science.gov (United States)

    Ferguson, Kelly K; Meeker, John D; McElrath, Thomas F; Mukherjee, Bhramar; Cantonwine, David E

    2017-05-01

    Preeclampsia is a prevalent and enigmatic disease, in part characterized by poor remodeling of the spiral arteries. However, preeclampsia does not always clinically present when remodeling has failed to occur. Hypotheses surrounding the "second hit" that is necessary for the clinical presentation of the disease focus on maternal inflammation and oxidative stress. Yet, the studies to date that have investigated these factors have used cross-sectional study designs or small study populations. In the present study, we sought to explore longitudinal trajectories, beginning early in gestation, of a panel of inflammation and oxidative stress markers in women who went on to have preeclamptic or normotensive pregnancies. We examined 441 subjects from the ongoing LIFECODES prospective birth cohort, which included 50 mothers who experienced preeclampsia and 391 mothers with normotensive pregnancies. Participants provided urine and plasma samples at 4 time points during gestation (median, 10, 18, 26, and 35 weeks) that were analyzed for a panel of oxidative stress and inflammation markers. Oxidative stress biomarkers included 8-isoprostane and 8-hydroxydeoxyguanosine. Inflammation biomarkers included C-reactive protein, the cytokines interleukin-1β, -6, and -10, and tumor necrosis factor-α. We created Cox proportional hazard models to calculate hazard ratios based on time of preeclampsia diagnosis in association with biomarker concentrations at each of the 4 study visits. In adjusted models, hazard ratios of preeclampsia were significantly (Pinflammation biomarkers that were measured at visit 2 (median, 18 weeks; hazard ratios, 1.31-1.83, in association with an interquartile range increase in biomarker). Hazard ratios at this time point were the most elevated for C-reactive protein, for interleukin-1β, -6, and -10, and for the oxidative stress biomarker 8-isoprostane (hazard ratio, 1.68; 95% confidence interval, 1.14-2.48) compared to other time points. Hazard ratios for

  7. C-reactive Protein: Repeated Measurements will Improve Dialysis Patient Care.

    Science.gov (United States)

    Cobo, Gabriela; Qureshi, Abdul Rashid; Lindholm, Bengt; Stenvinkel, Peter

    2016-01-01

    Systemic inflammation is a common feature in the uremic phenotype and associates with poor outcomes. The awareness regarding the importance of inflammation assessment in chronic kidney disease (CKD) patients has risen in recent years, and despite the development of novel biomarkers, C-reactive protein (CRP) is still the most measured inflammatory parameter. Notwithstanding, the possible weak points of CRP determination, this biomarker has demonstrated being useful both for guidance in clinical practice and for risk estimation. In addition, regular determination of CRP among dialysis patients has been associated with better outcomes in different dialysis facilities. Because persistent inflammation may be a silent reflection of various pathophysiologic alterations in CKD, it is crucial that inflammatory markers are regularly monitored and therapeutic attempts be made to target this inflammation.

  8. Repeated heart rate measurement and cardiovascular outcomes in left ventricular systolic dysfunction.

    Science.gov (United States)

    Hamill, Victoria; Ford, Ian; Fox, Kim; Böhm, Michael; Borer, Jeffrey S; Ferrari, Roberto; Komajda, Michel; Steg, Philippe Gabriel; Tavazzi, Luigi; Tendera, Michal; Swedberg, Karl

    2015-10-01

    Elevated resting heart rate is associated with increased cardiovascular risk, particularly in patients with left ventricular systolic dysfunction. Heart rate is not monitored routinely in these patients. We hypothesized that routine monitoring of heart rate would increase its prognostic value in patients with left ventricular systolic dysfunction. We analyzed the relationship between heart rate measurements and a range of adverse cardiovascular outcomes, including hospitalization for worsening heart failure, in the pooled placebo-treated patients from the morBidity-mortality EvAlUaTion of the If inhibitor ivabradine in patients with coronary disease and left ventricULar dysfunction (BEAUTIFUL) trial and Systolic Heart failure treatment with the If inhibitor ivabradine (SHIFT) Trial, using standard and time-varying covariate Cox proportional hazards models. By adjusting for other prognostic factors, models were fitted for baseline heart rate alone or for time-updated heart rate (latest heart rate) alone or corrected for baseline heart rate or for immediate previous time-updated heart rate. Baseline heart rate was strongly associated with all outcomes apart from hospitalization for myocardial infarction. Time-updated heart rate increased the strengths of associations for all outcomes. Adjustment for baseline heart rate or immediate previous time-updated heart rate modestly reduced the prognostic importance of time-updated heart rate. For hospitalization for worsening heart failure, each 5 beats/min increase in baseline heart rate and time-updated heart rate was associated with a 15% (95% confidence interval, 12-18) and 22% (confidence interval, 19-40) increase in risk, respectively. Even after correction, the prognostic value of time-updated heart rate remained greater. In patients with left ventricular systolic dysfunction, time-updated heart rate is more strongly related with adverse cardiovascular outcomes than baseline heart rate. Heart rate should be measured to

  9. Repeat-until-success quantum repeaters

    Science.gov (United States)

    Bruschi, David Edward; Barlow, Thomas M.; Razavi, Mohsen; Beige, Almut

    2014-09-01

    We propose a repeat-until-success protocol to improve the performance of probabilistic quantum repeaters. Conventionally, these rely on passive static linear-optics elements and photodetectors to perform Bell-state measurements (BSMs) with a maximum success rate of 50%. This is a strong impediment for entanglement swapping between distant quantum memories. Every time a BSM fails, entanglement needs to be redistributed between the corresponding memories in the repeater link. The key ingredients of our scheme are repeatable BSMs. Under ideal conditions, these turn probabilistic quantum repeaters into deterministic ones. Under realistic conditions, our protocol too might fail. However, using additional threshold detectors now allows us to improve the entanglement generation rate by almost orders of magnitude, at a nominal distance of 1000 km, compared to schemes that rely on conventional BSMs. This improvement is sufficient to make the performance of our scheme comparable to the expected performance of some deterministic quantum repeaters.

  10. Quantifying School Officials' Exposure to Bacterial Pathogens at Graduation Ceremonies Using Repeated Observational Measures

    Science.gov (United States)

    Bishai, David; Liu, Liang; Shiau, Stephanie; Wang, Harrison; Tsai, Cindy; Liao, Margaret; Prakash, Shivaani; Howard, Tracy

    2011-01-01

    The purpose of this study was to estimate the risk of acquiring pathogenic bacteria as a result of shaking hands at graduation ceremonies. School officials participating in graduation ceremonies at elementary, secondary, and postsecondary schools were recruited. Specimens were collected before and immediately following graduation. Cultures…

  11. Using high-dynamic-range digital repeat photography to measure plant phenology in a subarctic mire.

    Science.gov (United States)

    Garnello, A.; Dye, D. G.; Bogle, R.; Vogel, J.; Saleska, S. R.; Crill, P. M.

    2015-12-01

    A novel Visual Imaging System (VIS) was designed and deployed in a subarctic mire (68° 20' N, 19° 03'E) aimed at cataloging plant biological changes (phenology) and analyzing seasonal color shifts in relation to micrometeorological data along the summer growing season: June-November, 2015. The VIS is designed as a tower-based, solar-powered, automated phenology camera (Phenocam) that collects red, green, blue (RGB) and near-infrared (NIR) landscape images in High Dynamic Range (HDR) with fully programmable temporal resolution. HDR composite images are made through combining a series of rapid-capture photos with incremental increases of exposure times and a fixed focus, minimizing the spatial and visual data lost from shadows or from the over-saturation of light. This visual record of ecosystem phenology stages (Phenophases) is being used to (1) investigate vegetation-dependent spectral indices; (2) establish a cross-year comparison record of Phenophase seasonality; (3) investigate meteorological-dependent vegetation Phenophases; (4) provide ground-truthing measurements that enhance broader spatial-scale remote sensing analyses of subarctic wetlands.

  12. A Finite Mixture of Nonlinear Random Coefficient Models for Continuous Repeated Measures Data.

    Science.gov (United States)

    Kohli, Nidhi; Harring, Jeffrey R; Zopluoglu, Cengiz

    2016-09-01

    Nonlinear random coefficient models (NRCMs) for continuous longitudinal data are often used for examining individual behaviors that display nonlinear patterns of development (or growth) over time in measured variables. As an extension of this model, this study considers the finite mixture of NRCMs that combine features of NRCMs with the idea of finite mixture (or latent class) models. The efficacy of this model is that it allows the integration of intrinsically nonlinear functions where the data come from a mixture of two or more unobserved subpopulations, thus allowing the simultaneous investigation of intra-individual (within-person) variability, inter-individual (between-person) variability, and subpopulation heterogeneity. Effectiveness of this model to work under real data analytic conditions was examined by executing a Monte Carlo simulation study. The simulation study was carried out using an R routine specifically developed for the purpose of this study. The R routine used maximum likelihood with the expectation-maximization algorithm. The design of the study mimicked the output obtained from running a two-class mixture model on task completion data.

  13. Developing the Pieta House Suicide Intervention Model: a quasi-experimental, repeated measures design.

    LENUS (Irish Health Repository)

    Surgenor, Paul Wg

    2015-01-01

    While most crisis intervention models adhere to a generalised theoretical framework, the lack of clarity around how these should be enacted has resulted in a proliferation of models, most of which have little to no empirical support. The primary aim of this research was to propose a suicide intervention model that would resolve the client\\'s suicidal crisis by decreasing their suicidal ideation and improve their outlook through enhancing a range of protective factors. The secondary aim was to assess the impact of this model on negative and positive outlook.

  14. Are There Linguistic Markers of Suicidal Writing That Can Predict the Course of Treatment? A Repeated Measures Longitudinal Analysis.

    Science.gov (United States)

    Brancu, Mira; Jobes, David; Wagner, Barry M; Greene, Jeffrey A; Fratto, Timothy A

    2016-07-02

    The purpose of this pilot study was to predict resolution of suicidal ideation and risk over the course of therapy among suicidal outpatients (N = 144) using a novel method for analyzing Self- verses Relationally oriented qualitative written responses to the Suicide Status Form (SSF). A content analysis software program was used to extract word counts and a repeated measures longitudinal design was implemented to assess improvement over time. Patients with primarily Relationally focused word counts were more likely to have a quicker suicide risk resolution than those with more Self-focused word counts (6-7 sessions versus 17-18 sessions). Implications of these data are discussed, including the potential for enhancing treatment outcomes using this method with individuals entering treatment.

  15. A Bayesian model for repeated measures zero-inflated count data with application to outpatient psychiatric service use

    Science.gov (United States)

    Neelon, Brian H.; O’Malley, A. James; Normand, Sharon-Lise T.

    2009-01-01

    In applications involving count data, it is common to encounter an excess number of zeros. In the study of outpatient service utilization, for example, the number of utilization days will take on integer values, with many subjects having no utilization (zero values). Mixed-distribution models, such as the zero-inflated Poisson (ZIP) and zero-inflated negative binomial (ZINB), are often used to fit such data. A more general class of mixture models, called hurdle models, can be used to model zero-deflation as well as zero-inflation. Several authors have proposed frequentist approaches to fitting zero-inflated models for repeated measures. We describe a practical Bayesian approach which incorporates prior information, has optimal small-sample properties, and allows for tractable inference. The approach can be easily implemented using standard Bayesian software. A study of psychiatric outpatient service use illustrates the methods. PMID:21339863

  16. Retrodiction of a sequence of measurement results in qubit interferometers

    Science.gov (United States)

    Hillery, Mark; Koch, Daniel

    2016-09-01

    We study how well we can retrodict results of measurements made on a quantum system if we can make measurements on its final state. We know what measurements were made, but not their results. An initial examination shows that we can gain anywhere from no information to perfect information about the results of previous measurements, depending on the measurements and the initial state of the system. The case of two two-outcome measurements, the second of which is a projective measurement, is examined in some detail. We then look at a model of a qubit interferometer in which measurements are made in order to determine the path the qubit followed. The measurement made on the final state of the qubit depends on the information about previous measurement results that we are trying to determine. One can attempt to find the result of just one of the measurements or all of them or to find a measurement sequence that was not realized. We study all three possibilities.

  17. Diffusion-weighted magnetic resonance imaging for assessment of lung lesions: repeatability of the apparent diffusion coefficient measurement

    Energy Technology Data Exchange (ETDEWEB)

    Bernardin, L.; Douglas, N.H.M.; Collins, D.J.; Giles, S.L.; O' Flynn, E.A.M.; Orton, M.; DeSouza, N.M. [Institute of Cancer Research and Royal Marsden NHS Foundation Trust, CRUK and EPSRC Cancer Imaging Centre, Surrey (United Kingdom)

    2014-02-15

    To establish repeatability of apparent diffusion coefficients (ADCs) acquired from free-breathing diffusion-weighted magnetic resonance imaging (DW-MRI) in malignant lung lesions and investigate effects of lesion size, location and respiratory motion. Thirty-six malignant lung lesions (eight patients) were examined twice (1- to 5-h interval) using T1-weighted, T2-weighted and axial single-shot echo-planar DW-MRI (b = 100, 500, 800 s/mm{sup 2}) during free-breathing. Regions of interest around target lesions on computed b = 800 s/mm{sup 2} images by two independent observers yielded ADC values from maps (pixel-by-pixel fitting using all b values and a mono-exponential decay model). Intra- and inter-observer repeatability was assessed per lesion, per patient and by lesion size (> or <2 cm) or location. ADCs were similar between observers (mean ± SD, 1.15 ± 0.28 x 10{sup -3} mm{sup 2}/s, observer 1; 1.15 ± 0.29 x 10{sup -3} mm{sup 2}/s, observer 2). Intra-observer coefficients of variation of the mean [median] ADC per lesion and per patient were 11 % [11.4 %], 5.7 % [5.7 %] for observer 1 and 9.2 % [9.5 %], 3.9 % [4.7 %] for observer 2 respectively; inter-observer values were 8.9 % [9.3 %] (per lesion) and 3.0 % [3.7 %] (per patient). Inter-observer coefficient of variation (CoV) was greater for lesions <2 cm (n = 20) compared with >2 cm (n = 16) (10.8 % vs 6.5 % ADC{sub mean}, 11.3 % vs 6.7 % ADC{sub median}) and for mid (n = 14) vs apical (n = 9) or lower zone (n = 13) lesions (13.9 %, 2.7 %, 3.8 % respectively ADC{sub mean}; 14.2 %, 2.8 %, 4.7 % respectively ADC{sub median}). Free-breathing DW-MRI of whole lung achieves good intra- and inter-observer repeatability of ADC measurements in malignant lung tumours. (orig.)

  18. The method of analysis of joint space width measurement results: practical verification

    Science.gov (United States)

    Gilewska, Grażyna

    2006-02-01

    The difficulties in accuracy of performed measurements assessment was appeared when author analyzed measurement results of joint space width on the basis of radiographs. It's followed mainly from accuracy of patient position at X-ray unit. So that to solve this problem author worked out methods of elimination measured data of patients for which variation of measurement results was highest (i.e. lowest repeatability of radiographs execution). In this way we can perform fewer radiographs for the others patients to decrease of mean standard deviation of measured data identified with measuring error. Author checked practical application of methods outlying observation reduction and innovative methods of elimination measured data with excess variance at independence as well as dependence of variables. Elaborated methods were verified on the basis of measurement results of knee-joint width space got from radiographs. Measurements were carried out by two methods: directly on the radiographs as well as indirectly on the digital images of radiographs. Results of examination confirmed legitimacy to using of elaborated methodology and measurement procedures. It's solved important problems from metrology, which have application in many medical departments, especially if it's hard to achieve reduction of random error by increase numbers of measurements. Radiology is such a discipline. There is the most essential to reduce ionizing radiation dose for patient during examinations.

  19. MEMS Young's Modulus and Step Height Measurements With Round Robin Results.

    Science.gov (United States)

    Marshall, Janet; Allen, Richard A; McGray, Craig D; Geist, Jon

    2010-01-01

    This paper presents the results of a microelectromechanical systems (MEMS) Young's modulus and step height round robin experiment, completed in April 2009, which compares Young's modulus and step height measurement results at a number of laboratories. The purpose of the round robin was to provide data for the precision and bias statements of two \\ related Semiconductor Equipment and Materials International (SEMI) standard test methods for MEMS. The technical basis for the test methods on Young's modulus and step height measurements are also provided in this paper. Using the same test method, the goal of the round robin was to assess the repeatability of measurements at one laboratory, by the same operator, with the same equipment, in the shortest practical period of time as well as the reproducibility of measurements with independent data sets from unique combinations of measurement setups and researchers. Both the repeatability and reproducibility measurements were done on random test structures made of the same homogeneous material. The average repeatability Young's modulus value (as obtained from resonating oxide cantilevers) was 64.2 GPa with 95 % limits of ± 10.3 % and an average combined standard uncertainty value of 3.1 GPa. The average reproducibility Young's modulus value was 62.8 GPa with 95 % limits of ± 11.0 % and an average combined standard uncertainty value of 3.0 GPa. The average repeatability step height value (for a metal2-over-poly1 step from active area to field oxide) was 0.477 μm with 95 % limits of 7.9 % and an average combined standard uncertainty value of 0.014 μm. The average reproducibility step height value was 0.481 μm with 95 % limits of ± 6.2 % and an average combined standard uncertainty value of 0.014 μm. In summary, this paper demonstrates that a reliable methodology can be used to measure Young's modulus and step height. Furthermore, a micro and nano technology (MNT) 5-in-1 standard reference material (SRM) can be used by

  20. Ablation of the cardiac-specific gene leucine-rich repeat containing 10 (Lrrc10 results in dilated cardiomyopathy.

    Directory of Open Access Journals (Sweden)

    Matthew J Brody

    Full Text Available Leucine-rich repeat containing 10 (LRRC10 is a cardiac-specific protein exclusively expressed in embryonic and adult cardiomyocytes. However, the role of LRRC10 in mammalian cardiac physiology remains unknown. To determine if LRRC10 is critical for cardiac function, Lrrc10-null (Lrrc10(-/- mice were analyzed. Lrrc10(- (/- mice exhibit prenatal systolic dysfunction and dilated cardiomyopathy in postnatal life. Importantly, Lrrc10(-/- mice have diminished cardiac performance in utero, prior to ventricular dilation observed in young adults. We demonstrate that LRRC10 endogenously interacts with α-actinin and α-actin in the heart and all actin isoforms in vitro. Gene expression profiling of embryonic Lrrc10(-/- hearts identified pathways and transcripts involved in regulation of the actin cytoskeleton to be significantly upregulated, implicating dysregulation of the actin cytoskeleton as an early defective molecular signal in the absence of LRRC10. In contrast, microarray analyses of adult Lrrc10(-/- hearts identified upregulation of oxidative phosphorylation and cardiac muscle contraction pathways during the progression of dilated cardiomyopathy. Analyses of hypertrophic signal transduction pathways indicate increased active forms of Akt and PKCε in adult Lrrc10(-/- hearts. Taken together, our data demonstrate that LRRC10 is essential for proper mammalian cardiac function. We identify Lrrc10 as a novel dilated cardiomyopathy candidate gene and the Lrrc10(-/- mouse model as a unique system to investigate pediatric cardiomyopathy.

  1. Repeated testing improves achievement in a blended learning approach for risk competence training of medical students: results of a randomized controlled trial.

    Science.gov (United States)

    Spreckelsen, C; Juenger, J

    2017-09-26

    Adequate estimation and communication of risks is a critical competence of physicians. Due to an evident lack of these competences, effective training addressing risk competence during medical education is needed. Test-enhanced learning has been shown to produce marked effects on achievements. This study aimed to investigate the effect of repeated tests implemented on top of a blended learning program for risk competence. We introduced a blended-learning curriculum for risk estimation and risk communication based on a set of operationalized learning objectives, which was integrated into a mandatory course "Evidence-based Medicine" for third-year students. A randomized controlled trial addressed the effect of repeated testing on achievement as measured by the students' pre- and post-training score (nine multiple-choice items). Basic numeracy and statistical literacy were assessed at baseline. Analysis relied on descriptive statistics (histograms, box plots, scatter plots, and summary of descriptive measures), bootstrapped confidence intervals, analysis of covariance (ANCOVA), and effect sizes (Cohen's d, r) based on adjusted means and standard deviations. All of the 114 students enrolled in the course consented to take part in the study and were assigned to either the intervention or control group (both: n = 57) by balanced randomization. Five participants dropped out due to non-compliance (control: 4, intervention: 1). Both groups profited considerably from the program in general (Cohen's d for overall pre vs. post scores: 2.61). Repeated testing yielded an additional positive effect: while the covariate (baseline score) exhibits no relation to the post-intervention score, F(1, 106) = 2.88, p > .05, there was a significant effect of the intervention (repeated tests scenario) on learning achievement, F(1106) = 12.72, p blended learning approach can be improved significantly by implementing a test-enhanced learning design, namely repeated testing. As

  2. A single nucleotide variant in the FMR1 CGG repeat results in a "Pseudodeletion" and is not associated with the fragile X syndrome phenotype.

    Science.gov (United States)

    Cecconi, Massimiliano; Forzano, Francesca; Rinaldi, Rosanna; Cappellacci, Sandra; Grammatico, Paola; Faravelli, Francesca; Dagna Bricarelli, Franca; Di Maria, Emilio; Grasso, Marina

    2008-05-01

    The molecular diagnosis of fragile X syndrome relies on the detection of the pathogenic CGG repeat expansion in the FMR1 gene. Deletions and point mutations have occasionally been reported. Rare polymorphisms might mimic a deletion by Southern blot analysis, leading to false-positive results. We describe a novel rare nucleotide substitution within the CGG repeat. The proband was a woman with a positive family history of mental retardation. Southern blot analysis showed an additional band consistent with a deletion in the region detected by the StB12.3 probe. Sequencing of this region revealed a G>C transversion that interrupts the CGG repeat and introduces an EagI site. The same variant was observed in both the healthy son and father of the proband, supporting the hypothesis that the nucleotide substitution is a silent polymorphism, the frequency of which we estimated to be less than 1% in the general population. These findings argue for a pathogenic role of nucleotide variants within the CGG repeat and suggest possible consequences of unexpected findings in the molecular diagnostics of fragile X syndrome. Thus, although the sequence context of a single nucleotide substitution may not predict possible effects on mRNA or protein function, a specific change in the higher order structures of DNA or mRNA may be functionally relevant in the pathological phenotype.

  3. A Single Nucleotide Variant in the FMR1 CGG Repeat Results in a “Pseudodeletion” and Is Not Associated with the Fragile X Syndrome Phenotype

    Science.gov (United States)

    Cecconi, Massimiliano; Forzano, Francesca; Rinaldi, Rosanna; Cappellacci, Sandra; Grammatico, Paola; Faravelli, Francesca; Dagna Bricarelli, Franca; Di Maria, Emilio; Grasso, Marina

    2008-01-01

    The molecular diagnosis of fragile X syndrome relies on the detection of the pathogenic CGG repeat expansion in the FMR1 gene. Deletions and point mutations have occasionally been reported. Rare polymorphisms might mimic a deletion by Southern blot analysis, leading to false-positive results. We describe a novel rare nucleotide substitution within the CGG repeat. The proband was a woman with a positive family history of mental retardation. Southern blot analysis showed an additional band consistent with a deletion in the region detected by the StB12.3 probe. Sequencing of this region revealed a G>C transversion that interrupts the CGG repeat and introduces an EagI site. The same variant was observed in both the healthy son and father of the proband, supporting the hypothesis that the nucleotide substitution is a silent polymorphism, the frequency of which we estimated to be less than 1% in the general population. These findings argue for a pathogenic role of nucleotide variants within the CGG repeat and suggest possible consequences of unexpected findings in the molecular diagnostics of fragile X syndrome. Thus, although the sequence context of a single nucleotide substitution may not predict possible effects on mRNA or protein function, a specific change in the higher order structures of DNA or mRNA may be functionally relevant in the pathological phenotype. PMID:18403614

  4. The use of portable NIRS to measure muscle oxygenation and haemodynamics during a repeated sprint running test.

    Science.gov (United States)

    Jones, Ben; Hesford, Catherine M; Cooper, Chris E

    2013-01-01

    Portable near-infrared spectroscopy (NIRS) devices were originally developed for use in exercise and sports science by Britton Chance in the 1990s (the RunMan and microRunman series). However, only recently with the development of more robust, and wireless systems, has the routine use in elite sport become possible. As with the medical use of NIRS, finding applications of the technology that are relevant to practitioners is the key issue. One option is to use NIRS to track exercise training-induced adaptations in muscle. Portable NIRS devices enable monitoring during the normal 'field' routine uses to assess fitness, such as repeat sprint shuttle tests. Knowledge about the acute physiological responses to these specific tests has practical applications within team sport training prescription, where development of both central and peripheral determinants of high-intensity intermittent exercise needs to be considered. The purpose of this study was to observe NIRS-detected parameters during a repeat sprint test. We used the PortaMon, a two wavelength spatially resolved NIR spectrometer manufactured by Artinis Inc., to assess NIR changes in the gastrocnemius muscle of both the left and right leg during high-intensity running. Six university standard rugby players were assessed (age 20 ± 1.5 years; height 183 ± 1.0 cm; weight 89.4 ± 5.8 kg; body fat 12.2 ± 3.0 %); the subjects completed nine repeated shuttle runs, which incorporated forward, backward and change of direction movements. Individual sprint time, total time to complete test, blood lactate response (BL), heart rate values (HR) and haemoglobin variables (ΔHHb, ΔtHb, ΔHbO2 and ΔTSI%) were measured. Total time to complete the test was 260 ± 20 s, final blood lactate was 14.3 ± 2.8 mM, and maximal HR 182 ± 5 bpm. NIRS variables displayed no differences between right and left legs. During the test, the group-averaged data showed a clear decrease in HbO2 (max. decrease 11.41 ± 4.95 μM), increase in HHb

  5. The estimation of the measurement results with using statistical methods

    Science.gov (United States)

    Velychko, O.; Gordiyenko, T.

    2015-02-01

    The row of international standards and guides describe various statistical methods that apply for a management, control and improvement of processes with the purpose of realization of analysis of the technical measurement results. The analysis of international standards and guides on statistical methods estimation of the measurement results recommendations for those applications in laboratories is described. For realization of analysis of standards and guides the cause-and-effect Ishikawa diagrams concerting to application of statistical methods for estimation of the measurement results are constructed.

  6. Repeated-sprint cycling does not induce respiratory muscle fatigue in active adults: measurements from the powerbreathe® inspiratory muscle trainer.

    Science.gov (United States)

    Minahan, Clare; Sheehan, Beth; Doutreband, Rachel; Kirkwood, Tom; Reeves, Daniel; Cross, Troy

    2015-03-01

    This study examined respiratory muscle strength using the POWERbreathe® inspiratory muscle trainer (i.e., 'S-Index') before and after repeated-sprint cycling for comparison with maximal inspiratory pressure (MIP) values obtained during a Mueller maneuver. The S-Index was measured during six trials across two sessions using the POWERbreathe® and MIP was measured during three trials in a single session using a custom-made manometer in seven recreationally active adults. Global respiratory muscle strength was measured using both devices before and after the performance of sixteen, 6-s sprints on a cycle ergometer. Intraclass correlation coefficients for the POWERbreathe® S-index indicated excellent (p Repeated-sprint cycling had no effect on respiratory muscle strength as measured by the POWERbreathe® (p > 0.99) and during the Mueller maneuver (p > 0.99). The POWERbreathe® S-Index is a moderately reliable, but not equivalent, measure of MIP determined during a Mueller maneuver. Furthermore, repeated-sprint cycling does not induce globalized respiratory muscle fatigue in recreationally-active adults. Key pointsThe S-Index as measured by the POWERbreathe® is a reliable measure of respiratory muscle strengthThe S-Index does not accurately reflect maximal inspiratory pressure obtained from a Mueller maneuverRepeated-sprint cycling does not induce respiratory muscle fatigue as measured by the POWERbreathe® and the Manometer.

  7. Mass measurements and nuclear physics - recent results from ISOLTRAP

    Energy Technology Data Exchange (ETDEWEB)

    Herfurth, F [CERN, 1211 Geneva 23 (Switzerland); Ames, F [Sektion Physik, Ludwig-Maximilians-Universitaet, Muenchen, 85748 Garching (Germany); Audi, G [CSNSM-IN2P3-CNRS, 91405 Orsay-Campus (France); Beck, D [GSI, Planckstrasse 1, 64291 Darmstadt (Germany); Blaum, K [CERN, 1211 Geneva 23 (Switzerland); Bollen, G [NSCL, Michigan State University, East Lansing, MI 48824-1321 (United States); Kellerbauer, A [Sektion Physik, Ludwig-Maximilians-Universitaet, Muenchen, 85748 Garching (Germany); Kluge, H-J [GSI, Planckstrasse 1, 64291 Darmstadt (Germany); Kuckein, M [Sektion Physik, Ludwig-Maximilians-Universitaet, Muenchen, 85748 Garching (Germany); Lunney, D [CSNSM-IN2P3-CNRS, 91405 Orsay-Campus (France); Moore, R B [Department of Physics, McGill University, Montreal (Quebec) H3A 2T8 (Canada); Oinonen, M [Helsinki Institute of Physics, University of Helsinki, PO Box 9, 00014 Helsinki (Finland); Rodriguez, D [GSI, Planckstrasse 1, 64291 Darmstadt (Germany); Sauvan, E [CERN, 1211 Geneva 23 (Switzerland); Scheidenberger, C [GSI, Planckstrasse 1, 64291 Darmstadt (Germany); Schwarz, S [NSCL, Michigan State University, East Lansing, MI 48824-1321 (United States); Sikler, G [GSI, Planckstrasse 1, 64291 Darmstadt (Germany); Weber, C [GSI, Planckstrasse 1, 64291 Darmstadt (Germany)

    2003-03-14

    The Penning trap mass spectrometer ISOLTRAP is a facility for high-precision mass measurements of short-lived radioactive nuclei installed at ISOLDE/CERN in Geneva. More than 200 masses have been measured with relative uncertainties of 1 x 10{sup -7} or even close to 1 x 10{sup -8} in special cases. This publication gives an overview of the measurements performed with ISOLTRAP and discusses some results.

  8. Factors affecting SPF in vitro measurement and correlation with in vivo results.

    Science.gov (United States)

    Dimitrovska Cvetkovska, A; Manfredini, S; Ziosi, P; Molesini, S; Dissette, V; Magri, I; Scapoli, C; Carrieri, A; Durini, E; Vertuani, S

    2017-06-01

    The in vitro evaluation of SPF is still a problem due to the lack of repeatability and correlation between the in vitro and in vivo data, and many authors are currently working to develop an internationally harmonized method. Very recently, the use of several "adjuvant" ingredients such as boosters, antioxidants, immunomodulators, solvents and film-forming ingredients have further complicated the pattern for product developers that should frequently run in vivo test. The aim of this study was to understand whether a simple and cheap in vitro method could be optimized in order to provide both statistically repeatable and predictive SPF measurement. In vitro SPF assessments were carried out on 75 commercial products. The SPF was measured according to two laboratory methods (A and B), using different substrates (PMMA and surgical tape Transpore™), quantity of product and spectrophotometers. In order to evaluate whether a standard technique of spreading could lead to a statistically reliable result, we applied different spreading pressure (100 g and 200 g). Furthermore, we investigate whether other parameters characterizing the product (SPF category, filter and texture) might represent statically significant variables affecting the measures. We then compared the results obtained from in vitro SPF measure of 11 products to in vivo SPF, in order to assess the predictability of in vitro methods. Several problems were encountered in confirming the weakness of the in vitro procedures. Pressure, SPF category, filter and texture did not affect significantly the results. Overall best results were obtained with the B2 method that in terms of repeatability and predictivity provided statistically better results. Method A with Transpore™ tape showed better in vitro-in vivo correlation than Method B with PMMA plates. In our investigation, we demonstrated that it is possible for a single laboratory to optimize internal methods and protocols to achieve repeatable and predictive

  9. Results of the First TOF Mass Measurements at NSCL

    Science.gov (United States)

    Matos, M.; Estrade, A.; Amthor, M.; Bazin, D.; Becerril, A.; Elliot, T.; Galaviz, D.; Gade, A.; Lorusso, G.; Pereira, J.; Portillo, M.; Rogers, A.; Schatz, H.; Stolz, A.; Shapira, D.; Smith, E.; Wallace, M.

    2008-04-01

    Time-of-Flight mass measurements technique, recently developed at the NSCL, MSU, was used to measure masses of exotic neutron-rich nuclides in the Fe region, important for r-process calculations as well as for calculations of processes occurring in the crust of accreting neutron stars. Results from the experiment will be presented and discussed.

  10. A method to construct a points system to predict cardiovascular disease considering repeated measures of risk factors

    Science.gov (United States)

    Carbayo-Herencia, Julio Antonio; Vigo, Maria Isabel; Gil-Guillén, Vicente Francisco

    2016-01-01

    Current predictive models for cardiovascular disease based on points systems use the baseline situation of the risk factors as independent variables. These models do not take into account the variability of the risk factors over time. Predictive models for other types of disease also exist that do consider the temporal variability of a single biological marker in addition to the baseline variables. However, due to their complexity these other models are not used in daily clinical practice. Bearing in mind the clinical relevance of these issues and that cardiovascular diseases are the leading cause of death worldwide we show the properties and viability of a new methodological alternative for constructing cardiovascular risk scores to make predictions of cardiovascular disease with repeated measures of the risk factors and retaining the simplicity of the points systems so often used in clinical practice (construction, statistical validation by simulation and explanation of potential utilization). We have also applied the system clinically upon a set of simulated data solely to help readers understand the procedure constructed. PMID:26893963

  11. Repeated measurements of cerebral blood flow in the left superior temporal gyrus reveal tonic hyperactivity in patients with auditory verbal hallucinations: A possible trait marker

    Directory of Open Access Journals (Sweden)

    Philipp eHoman

    2013-06-01

    Full Text Available Background: The left superior temporal gyrus (STG has been suggested to play a key role in auditory verbal hallucinations in patients with schizophrenia. Methods: Eleven medicated subjects with schizophrenia and medication-resistant auditory verbal hallucinations and 19 healthy controls underwent perfusion magnetic resonance imaging with arterial spin labeling. Three additional repeated measurements were conducted in the patients. Patients underwent a treatment with transcranial magnetic stimulation (TMS between the first 2 measurements. The main outcome measure was the pooled cerebral blood flow (CBF, which consisted of the regional CBF measurement in the left superior temporal gyrus (STG and the global CBF measurement in the whole brain.Results: Regional CBF in the left STG in patients was significantly higher compared to controls (p < 0.0001 and to the global CBF in patients (p < 0.004 at baseline. Regional CBF in the left STG remained significantly increased compared to the global CBF in patients across time (p < 0.0007, and it remained increased in patients after TMS compared to the baseline CBF in controls (p < 0.0001. After TMS, PANSS (p = 0.003 and PSYRATS (p = 0.01 scores decreased significantly in patients.Conclusions: This study demonstrated tonically increased regional CBF in the left STG in patients with schizophrenia and auditory hallucinations despite a decrease in symptoms after TMS. These findings were consistent with what has previously been termed a trait marker of auditory verbal hallucinations in schizophrenia.

  12. Method and results of studying conduction measuring transducers

    Energy Technology Data Exchange (ETDEWEB)

    Dunaevskii, I.G.; Korotkov, B.N.; Povkh, I.L.; Cheplyukov, V.G.

    1977-01-01

    The method and results are given for determining the sensitivity of conduction measuring transducers with a local magnetic field. The results were obtained by frequency-dependent gradation on a model pulsation velocity gauge--a thermoanemometer. The effect of measuring a transducer's diameter, inter-electrode distance and nose line forms on its spatial resolution capacity was estimated. Adjustment functions were obtained for these transducers. A concept was formulated for measuring transducers belonging to the same class. 5 references, 5 figures.

  13. Diabetic Foot Prevention: Repeatability of the Loran Platform Plantar Pressure and Load Distribution Measurements in Nondiabetic Subjects during Bipedal Standing—A Pilot Study

    Directory of Open Access Journals (Sweden)

    Martha Zequera

    2011-01-01

    Full Text Available This study was designed to assess the repeatability of the Loran Platform and evaluate the variability of plantar pressure and postural balance, during barefoot standing in nondiabetic subjects, for future diabetic foot clinical evaluation. Measurements were taken for eight nondiabetic subjects (4 females, 4 males, aged 47±7.2 years who had no musculoskeletal symptoms. Five variables were measured with the platform in the barefoot standing position. Ten measurements were taken using two different techniques for feet and posture positioning, during three sessions, once a week. For most measurements, no significant effect over time was found with Student's t-test (P<.000125. The ANOVA test of statistical significance confirmed that measurement differences between subjects showed higher variations than measurements taken from the same subject (P<.001. The measurements taken by the Loran Platform system were found to be repeatable.

  14. 躯体X线测量板的研制和应用%Validation and repeatability of Limb X Film Measuring Plate

    Institute of Scientific and Technical Information of China (English)

    卫小春; 柴旭峰; 许趁心

    2008-01-01

    Objective To study the efficacy and repeatability of the Limb X Film Measuring Plate (LXMP)in clinical x film measurement of lengths and angles of limbs.Methods The LXMP was de- signed and manufactured for testing.Three known points in 9 templates were taken as golden standards.which were to be compared with measuring results of these projected points on the X film for testing efficacy of LXMP.Twenty-one patients with knees osteoarthritis were selected.The lengths and angles of their lower limbs were measured twice with the help of LXMP by an observer at different time intervals for testing in. Tra-observer repeatability.Two observers measured once on films at the same time for testing inter-observer repeatability.The correlation coefficients,mean absolute difierences between the repeated measurements,and error rate were calculated. Results The points on LXMP could be seen clearly on X film.Validation tests showed the differences in angle measurement between golden standards and measuring results for those pro- jeted points on the X film were insignificant.with mean absolute difference being O.10.-0.21,error rate being 0.12%-3.15%and r being close to 1.The differences in length measurement were insignificant ei- ther,with mean absolute differenee being 0.05 cm-0.16 cm.error rate being 0.12%-o.28%and r being close to 1.The intra-observer repeatability test for beth angles and lengths showed that r was close to I.mean absolute diffefences 0.55.and 0.1-0.37cm and error rate 0.3l%-O.97%.while the inter-observer re- peatability test showed that r was close to 1.mean absolute difierences o.39.and0.05-0.13cm and error rate O.16%-O.35%. Conclusion The Limb X Film Measuring Plate Can be used for accurately mcasuring limb lengths and angles with good efficacy and repeatability.%目的 介绍躯体X线测量板的制作方法 ,探讨其有效性、重复性,为临床X线测量提供一套精确、实用、经济的方法 和工具.方法 设计和制作躯体X线

  15. Repeated measurements of blood lactate concentration as a prognostic marker in horses with acute colitis evaluated with classification and regression trees (CART) and random forest analysis.

    Science.gov (United States)

    Petersen, M B; Tolver, A; Husted, L; Tølbøll, T H; Pihl, T H

    2016-07-01

    The objective of this study was to investigate the prognostic value of single and repeated measurements of blood l-lactate (Lac) and ionised calcium (iCa) concentrations, packed cell volume (PCV) and plasma total protein (TP) concentration in horses with acute colitis. A total of 66 adult horses admitted with acute colitis (2 mmol/L (sensitivity, 0.72; specificity, 0.8). In conclusion, blood lactate concentration measured at admission and repeated 6 h later aided the prognostic evaluation of horses with acute colitis in this population with a very high mortality rate. This should allow clinicians to give a more reliable prognosis for the horse.

  16. Cardiac output measurement in newborn infants using the ultrasonic cardiac output monitor: an assessment of agreement with conventional echocardiography, repeatability and new user experience.

    Science.gov (United States)

    Patel, Neil; Dodsworth, Melissa; Mills, John F

    2011-05-01

    To assess (1) agreement between the ultrasonic cardiac output monitor (USCOM) 1A device for measurement of cardiac output in newborn infants and conventional echocardiography (ECHO), (2) repeatability of USCOM measurements and (3) agreement between novice and expert users of the USCOM. A prospective observational study. The Neonatal Unit at the Royal Children's Hospital, Melbourne, Australia. 56 term and near-term infants, with no evidence of structural or functional cardiovascular disease, or haemodynamic shunts. Agreement between ECHO and USCOM was assessed by paired measurements of ventricular outputs by a single experienced user. Repeatability was assessed using five repeated measurements in 10 infants. Agreement between five novices and one expert user was assessed by paired USCOM measurements over 30 training measurements. Agreement between USCOM and ECHO for left ventricular output (LVO) was (bias, ±limits of agreement, mean % error): 14, ±108 ml/kg/min, 43%, and for right ventricular output (RVO): -59, ±160, ml/kg/min, 57%. Intra-observer repeatability was 6.7% for USCOM LVO and 3.6% for ECHO LVO. After five training measurements, the mean difference between USCOM measures of LVO by novice and expert users was less than 50 ml/kg/min, but with variability. Repeatability of USCOM measures is high in newborn infants. New users can be trained quickly, but with high inter-user variability. Agreement between USCOM and conventional ECHO is broad, and worse for RVO and LVO. Further studies are required to assess the ability of the device to detect clinically significant changes in infant cardiac output.

  17. Relationship between measures of aerobic fitness, speed and repeated sprint ability in full and part time youth soccer players.

    Science.gov (United States)

    Gibson, N; Currie, J; Johnston, R; Hill, J

    2013-02-01

    The aim of the study was to investigate the relationship between repeated sprint ability (RSA) involving changes in direction, short linear sprinting and aerobic capacity in young elite soccer players. A secondary aim was to assess any differences in performance of these assessments between players of different age groups. Thirty-two male adolescent soccer players belonging to the same elite club academy were assessed for RSA comprising 6 x 40m efforts interspersed by 25s recovery, linear sprinting speed over 15m, and aerobic capacity via the YYIE2 assessment. There was a significant correlation between performance in the YYIE2 and RSA total time, RSA fastest sprint and RSA percentage decrement (r = -0.71, -0.53, and -0.52 respectively. Psprint (Psprinting. Assessments of RSA over 40m and incorporating changes of direction appear to be significantly correlated with YYIE2 performance in young elite level soccer players. In addition older players performed significantly better in the YYIE2 assessment and RSA protocol but not in short linear sprinting. These results have implications for the design of assessment protocols for young elite soccer players of different ages.

  18. UK 2009-2010 repeat station report

    Directory of Open Access Journals (Sweden)

    Thomas J.G. Shanahan

    2013-03-01

    Full Text Available The British Geological Survey is responsible for conducting the UK geomagnetic repeat station programme. Measurements made at the UK repeat station sites are used in conjunction with the three UK magnetic observatories: Hartland, Eskdalemuir and Lerwick, to produce a regional model of the local field each year. The UK network of repeat stations comprises 41 stations which are occupied at approximately 3-4 year intervals. Practices for conducting repeat station measurements continue to evolve as advances are made in survey instrumentation and as the usage of the data continues to change. Here, a summary of the 2009 and 2010 UK repeat station surveys is presented, highlighting the measurement process and techniques, density of network, reduction process and recent results.

  19. Application of Molecular Typing Results in Source Attribution Models: The Case of Multiple Locus Variable Number Tandem Repeat Analysis (MLVA) of Salmonella Isolates Obtained from Integrated Surveillance in Denmark

    DEFF Research Database (Denmark)

    de Knegt, Leonardo; Pires, Sara Monteiro; Löfström, Charlotta

    2016-01-01

    number tandem repeat analysis (MLVA) substituted phage typing as the subtyping method for surveillance of S. Enteritidis and S. Typhimurium isolated from animals, food, and humans in Denmark. The purpose of this study was to develop a modeling approach applying a combination of serovars, MLVA types......, and antibiotic resistance profiles for the Salmonella source attribution, and assess the utility of the results for the food safety decisionmakers. Full and simplified MLVA schemes from surveillance data were tested, and model fit and consistency of results were assessed using statistical measures. We conclude...

  20. Preliminary results of ground reflectivity measurements using noise radar

    Science.gov (United States)

    Maślikowski, Łukasz; Krysik, Piotr; Dąbrowska-Zielińska, Katarzyna; Kowalik, Wanda; Bartold, Maciej

    2011-10-01

    The paper describes experimental L-band ground reflectivity measurement using noise radar demonstrator working as a scatterometer. The radar ground return is usually described with a scattering coefficient, a quantity that is independent from the scatterometer system. To calculate the coefficient in a function of incidence angle, range profile values obtained after range compression were used. In order to improve dynamic range of the measurement, antenna cross-path interference was removed using lattice filter. The ground return was measured at L band both for HH and VV polarizations of radar wave as well as for HV and VH crosspolarizations using log-periodic antennas placed at a 10 m high mast directed towards a meadow surface. In the paper the theoretical considerations, noise radar setup, measurement campaign and the results are described.

  1. The Effects of Group Leader Learning Style on Student Knowledge Gain in a Leadership Camp Setting: A Repeated-Measures Experiment

    Science.gov (United States)

    Brown, Nicholas R.; Terry, Robert, Jr.

    2013-01-01

    Many state FFA associations conduct summer camps focusing on leadership and personal development for FFA members. Interestingly, little research has been conducted on the impact or outcomes of these common activities. The purpose of this split-plot factorial repeated-measures experiment was to assess the level of campers' learning of the…

  2. Power and sample size for the S:T repeated measures design combined with a linear mixed-effects model allowing for missing data.

    Science.gov (United States)

    Tango, Toshiro

    2017-02-13

    Tango (Biostatistics 2016) proposed a new repeated measures design called the S:T repeated measures design, combined with generalized linear mixed-effects models and sample size calculations for a test of the average treatment effect that depend not only on the number of subjects but on the number of repeated measures before and after randomization per subject used for analysis. The main advantages of the proposed design combined with the generalized linear mixed-effects models are (1) it can easily handle missing data by applying the likelihood-based ignorable analyses under the missing at random assumption and (2) it may lead to a reduction in sample size compared with the simple pre-post design. In this article, we present formulas for calculating power and sample sizes for a test of the average treatment effect allowing for missing data within the framework of the S:T repeated measures design with a continuous response variable combined with a linear mixed-effects model. Examples are provided to illustrate the use of these formulas.

  3. Quantum repeated games revisited

    CERN Document Server

    Frackiewicz, Piotr

    2011-01-01

    We present a scheme for playing quantum repeated 2x2 games based on the Marinatto and Weber's approach to quantum games. As a potential application, we study twice repeated Prisoner's Dilemma game. We show that results not available in classical game can be obtained when the game is played in the quantum way. Before we present our idea, we comment on the previous scheme of playing quantum repeated games.

  4. HOMs Simulation and Measurement Results of IHEP02 Cavity

    CERN Document Server

    Zheng, Hongjuan; Zhao, Tongxian; Gao, Jie

    2015-01-01

    In cavities, there exists not only the fundamental mode which is used to accelerate the beam but also higher order modes (HOMs). The higher order modes excited by beam can seriously affect beam quality, especially for the higher R/Q modes. This paper reports on measured results of higher order modes in the IHEP02 1.3GHz low-loss 9-cell superconducting cavity. Using different methods, Qe of the dangerous modes passbands have been got. The results are compared with TESLA cavity results. R/Q of the first three passbands have also been got by simulation and compared with the results of TESLA cavity.

  5. Recent results on Higgs measurements and searches in ATLAS

    CERN Document Server

    CERN. Geneva

    2016-01-01

    The excellent operation of the LHC, and a fast processing and analysis, has enabled ATLAS to produce many new results during the last months with similar or better sensitivity than the one reached during Run 1 of the LHC. The seminar will give an overview of the Standard Model Higgs boson measurements and of searches for non-standard scalar states or decay modes.

  6. Measurement of Surface Displacement and Deformation of Mass Movements Using Least Squares Matching of Repeat High Resolution Satellite and Aerial Images

    Directory of Open Access Journals (Sweden)

    Misganu Debella-Gilo

    2012-01-01

    Full Text Available Displacement and deformation are fundamental measures of Earth surface mass movements such as glacier flow, rockglacier creep and rockslides. Ground-based methods of monitoring such mass movements can be costly, time consuming and limited in spatial and temporal coverage. Remote sensing techniques, here matching of repeat optical images, are increasingly used to obtain displacement and deformation fields. Strain rates are usually computed in a post-processing step based on the gradients of the measured velocity field. This study explores the potential of automatically and directly computing velocity, rotation and strain rates on Earth surface mass movements simultaneously from the matching positions and the parameters of the geometric transformation models using the least squares matching (LSM approach. The procedures are exemplified using bi-temporal high resolution satellite and aerial images of glacier flow, rockglacier creep and land sliding. The results show that LSM matches the images and computes longitudinal strain rates, transverse strain rates and shear strain rates reliably with mean absolute deviations in the order of 10−4 (one level of significance below the measured values as evaluated on stable grounds. The LSM also improves the accuracy of displacement estimation of the pixel-precision normalized cross-correlation by over 90% under ideal (simulated circumstances and by about 25% for real multi-temporal images of mass movements.

  7. Repeat, Low Altitude Measurements of Vegetation Status and Biomass Using Manned Aerial and UAS Imagery in a Piñon-Juniper Woodland

    Science.gov (United States)

    Krofcheck, D. J.; Lippitt, C.; Loerch, A.; Litvak, M. E.

    2015-12-01

    Measuring the above ground biomass of vegetation is a critical component of any ecological monitoring campaign. Traditionally, biomass of vegetation was measured with allometric-based approach. However, it is also time-consuming, labor-intensive, and extremely expensive to conduct over large scales and consequently is cost-prohibitive at the landscape scale. Furthermore, in semi-arid ecosystems characterized by vegetation with inconsistent growth morphologies (e.g., piñon-juniper woodlands), even ground-based conventional allometric approaches are often challenging to execute consistently across individuals and through time, increasing the difficulty of the required measurements and consequently the accuracy of the resulting products. To constrain the uncertainty associated with these campaigns, and to expand the extent of our measurement capability, we made repeat measurements of vegetation biomass in a semi-arid piñon-juniper woodland using structure-from-motion (SfM) techniques. We used high-spatial resolution overlapping aerial images and high-accuracy ground control points collected from both manned aircraft and multi-rotor UAS platforms, to generate digital surface model (DSM) for our experimental region. We extracted high-precision canopy volumes from the DSM and compared these to the vegetation allometric data, s to generate high precision canopy volume models. We used these models to predict the drivers of allometric equations for Pinus edulis and Juniperous monosperma (canopy height, diameter at breast height, and root collar diameter). Using this approach, we successfully accounted for the carbon stocks in standing live and standing dead vegetation across a 9 ha region, which contained 12.6 Mg / ha of standing dead biomass, with good agreement to our field plots. Here we present the initial results from an object oriented workflow which aims to automate the biomass estimation process of tree crown delineation and volume calculation, and partition

  8. The Recent Results of the Solar Neutrino Measurement in Borexino

    CERN Document Server

    Koshio, Yusuke

    2011-01-01

    The recent released results of 153.62 ton year exposure of solar neutrino data in Borexino are here discussed. Borexino is a multi-purpose detector with large volume liquid scintillator, located in the underground halls of the Laboratori Nazionali del Gran Sasso in Italy. The experiment is running since 2007. The first realtime 7Be solar neutrino measurement has been released in 2008. Thanks to the precise detector calibration in 2009, the 7Be flux measurement has been reached with an accuracy better than 5%. The result related to the day/night effect in the $^7$Be energy region is also discussed. These results validate the MSW-LMA model for solar neutrino oscillation.

  9. Recent results from the MISTRAL mass measurement program at ISOLDE

    CERN Document Server

    Lunney, M D; Audi, G; Bollen, G; Borcea, C; Doubre, H; Gaulard, C; Henry, S; De Saint-Simon, M; Thibault, C; Toader, C F; Vieira, N

    2001-01-01

    The MISTRAL experiment (Mass measurements at ISOLDE with a Transmission and Radiofrequency spectrometer on-Line), conceived for very short-lived nuclides, has reached the end of its commissioning phase. Installed in 1997, results have been obtained consistent with all aspects of the projected spectrometer performance: nuclides with half-lives as short as 30 ms have been measured and accuracies of $\\pm$0.4 have been achieved, despite the presence of a systematic shift and difficulties with isobaric contamination. Masses of several nuclides, including $^{25-26}\\!$Ne and $^{32}$Mg that forms the famous island of inversion around N=20, have been significantly improved.

  10. Results of ionospheric measurements, got on micro satellite "Compass-2"

    Science.gov (United States)

    Dokukin, Vladimir; Kuznetsov, V. D.; Garipov, G. K.; Kapustina, O.; Mikhailov, Yu. M.; Mikhailova, G. A.; Ruzhin, Yu. Ya.; Sinelnikov, V. M.; Shirokov, A. V.; Yashin, I. V.; Danilkin, V. A.; Degtyar, V. G.

    Results of measurements, executed by complex of scientific instruments of micro satellite Compass-2 in the period of 2006-2007, are presented. The project was aimed on registration and study of ionospheric effects, related to the natural and anthropogenic anomalous phenomena. The effects of interaction of solar wind with magnetosphere in the period of flare activity of the Sun and anomalous low frequency radiations, happened one day before the earthquake with magnitude 4.2, are registered. The data was got on measurements of corpuscular radiation, wide band radiations and low frequency waves along the orbit of satellite.

  11. Analyzing repeated data collected by mobile phones and frequent text messages. An example of Low back pain measured weekly for 18 weeks

    DEFF Research Database (Denmark)

    Axén, Iben; Bodin, Lennart; Kongsted, Alice

    2012-01-01

    ABSTRACT: BACKGROUND: Repeated data collection is desirable when monitoring fluctuating conditions. Mobile phones can be used to gather such data from large groups of respondents by sending and receiving frequently repeated short questions and answers as text messages. The analysis of repeated data...... for the clinical researcher in order for complex outcome measures to be interpreted in a clinically meaningful way. METHODS: A model data set was formed using data from two clinical studies, where patients with low back pain were followed with weekly text messages for 18 weeks. Different research questions...... questions with appropriate analytical methods 1: How many days with pain do patients experience? This question was answered with data summaries. 2: What is the proportion of participants "recovered" at a specific time point? This question was answered using logistic regression analysis. 3: What is the time...

  12. Evaluation, including effects of storage and repeated freezing and thawing, of a method for measurement of urinary creatinine

    DEFF Research Database (Denmark)

    Garde, A H; Hansen, Åse Marie; Kristiansen, J

    2003-01-01

    The aims of this study were to elucidate to what extent storage and repeated freezing and thawing influenced the concentration of creatinine in urine samples and to evaluate the method for determination of creatinine in urine. The creatinine method was based on the well-known Jaffe's reaction and...

  13. Heart rate variability and DNA methylation levels are altered after short-term metal fume exposure among occupational welders: a repeated-measures panel study

    OpenAIRE

    2014-01-01

    Background: In occupational settings, boilermakers are exposed to high levels of metallic fine particulate matter (PM2.5) generated during the welding process. The effect of welding PM2.5 on heart rate variability (HRV) has been described, but the relationship between PM2.5, DNA methylation, and HRV is not known. Methods: In this repeated-measures panel study, we recorded resting HRV and measured DNA methylation levels in transposable elements Alu and long interspersed nuclear element-1 (LINE...

  14. Repeated measures dose-finding design with time-trend detection in the presence of correlated toxicity data.

    Science.gov (United States)

    Yin, Jun; Paoletti, Xavier; Sargent, Daniel J; Mandrekar, Sumithra J

    2017-08-01

    Phase I trials are designed to determine the safety, tolerability, and recommended phase 2 dose of therapeutic agents for subsequent testing. The dose-finding paradigm has thus traditionally focused on identifying the maximum tolerable dose of an agent or combination therapy under the assumption that there is a non-decreasing relationship between dose-toxicity and dose-efficacy. The dose is typically determined based on the probability of severe toxicity observed during the first treatment cycle. A novel endpoint, the total toxicity profile, was previously developed to account for the multiple toxicity types and grades experienced in the first cycle. More recently, this was extended to a repeated measures design based on the total toxicity profile to account for longitudinal toxicities over multiple treatment cycles in the absence of within-patient correlation. In this work, we propose to extend the design in the presence of within-patient correlation. Furthermore, we provide a framework to detect a toxicity time trend (toxicity increasing, decreasing, or stable) over multiple treatment cycles. We utilize a linear mixed model in the Bayesian framework, with the addition of Bayesian risk functions for decision-making in dose assignment. The performance of this design was evaluated using simulation studies and real data from a phase I trial. We demonstrated that using available toxicity data from all cycles of treatment improves the accuracy of maximum tolerated dose identification and allows for the detection of a time trend. The performance is consistent regardless of the strength of the within-patient correlation. In addition, the use of a quasi-continuous total toxicity profile score significantly increased the power to detect time trends compared to when binary data only were used. The increased interest in molecularly targeted agents and immunotherapies in oncology necessitates innovative phase I study designs. Our proposed framework provides a tool to tackle

  15. 基于同频RF直放站的回波测量方法%Technique of measuring the echo for RF repeaters in single frequency networks

    Institute of Scientific and Technical Information of China (English)

    陈哲; 宋葛

    2011-01-01

    直放站的同频转发模式存在收发天线间互耦的问题,接收天线在接收主基站的信号时,同时接收到直放站发射天线发射的信号,以同频RF直放站调试隔离度为技术背景,提出了同频RF直放站的回波测量方法.该方法利用CAZAC码实现的初估计快速地估计出回波信道的特性,自适应LMS算法的使用可以进一步跟踪信道的变化.通过MATLAB仿真后,在数字硬件平台上用FPGA实现该方法,并用数字电视信号CMMB做为信号源对系统进行了测试,结果说明此种测量方法准确、实用.%The signal transition mode of repeater which works on the same frequency has some troubles on signal coupling between receive and transmit aerials,the signal from transmit aerial may leak out into receive aerial. This paper presents a method of measuring the echo under the context of isolation test for RF repeaters in single frequency networks. The experimental apparatus firstly uses CAZAC code as the method of channel initial estimation, secondly uses LMS arithmetic to track the change of the channel. After the MATLAB simulation realization has been achieved by FPGA on real digital hardware board. The result of test which uses DTV signal (CMMB) as the source proves the function of method achieved accurately.

  16. Results form RESUME 95. Measurements with mobile equipment

    Energy Technology Data Exchange (ETDEWEB)

    Lidstroem, K.; Ulvsand, T.; Aagren, G. [National Defence Research Establisment, Div. of Ionising Radiation and Fallout, Umeaa (Sweden)

    1997-12-31

    This paper presents the results obtained during the NKS, (EKO-3), Exercise Resume-95 by a group from the Division of Ionising Radiation and Fallout, FOA, Umeaa, Sweden. Field gamma measurements were performed in two areas with a HPGe-detector (p-type, 50% relative efficiency) mounted vertically 1 m above the ground or horizontally in a car. One of the areas was an airfield, Vesivehmaa, where 19 measurements were done. The calculated Cs-137 activity was 52.1 {+-} 4.5 kBq/m{sup 2} assuming a two slice distribution model with a homogenous density and activity distribution in each slice. The report contains also the results from a task which included the finding, classification and estimation of the activity of hidden sources within two 10{sup *} 10 m-areas. (au).

  17. The effects of repeated-sprint training on field-based fitness measures: a meta-analysis of controlled and non-controlled trials.

    Science.gov (United States)

    Taylor, Jonathan; Macpherson, Tom; Spears, Iain; Weston, Matthew

    2015-06-01

    Repeated-sprint training appears to be an efficient and practical means for the simultaneous development of different components of fitness relevant to team sports. Our objective was to systematically review the literature and meta-analyse the effect of repeated-sprint training on a selection of field-based measures of athletic performance, i.e. counter-movement jump, 10 m sprint, 20 m sprint, 30 m sprint, repeated-sprint ability and high-intensity intermittent running performance. The SPORTDiscus, PubMed, MEDLINE and Web of Science databases were searched for original research articles. Search terms included 'repeated-sprint training', 'sprint training', 'aerobic endurance', 'repeated-sprint ability', 'counter-movement jump' and 'sprint performance'. Inclusion criteria included intervention consisting of a series of ≤10 s sprints with ≤60 s recovery; trained participants; intervention duration of 2-12 weeks; field-based fitness measures; running- or cycling-based intervention; published up to, and including, February 2014. Our final dataset included six trials for counter-movement jump (two controlled trials), eight trials for 10 m sprint, four trials for 20 m sprint (three controlled trials), two trials for 30 m sprint, eight trials for repeated-sprint ability and three trials for high-intensity intermittent running performance. Analyses were conducted using comprehensive meta-analysis software. Uncertainty in the meta-analysed effect of repeated-sprint training was expressed as 95% confidence limits (CL), along with the probability that the true value of the effect was trivial, beneficial or harmful. Magnitude-based inferences were based on standardised thresholds for small, moderate and large changes of 0.2, 0.6 and 1.2 standard deviations, respectively. Repeated-sprint training had a likely small beneficial effect in non-controlled counter-movement jump trials (effect size 0.33; 95% CL ±0.30), with a possibly moderate beneficial effect in controlled

  18. Over-expression of rice leucine-rich repeat protein results in activation of defense response, thereby enhancing resistance to bacterial soft rot in Chinese cabbage.

    Science.gov (United States)

    Park, Young Ho; Choi, Changhyun; Park, Eun Mi; Kim, Hyo Sun; Park, Hong Jae; Bae, Shin Cheol; Ahn, Ilpyung; Kim, Min Gab; Park, Sang Ryeol; Hwang, Duk-Ju

    2012-10-01

    Pectobacterium carotovorum subsp. carotovorum causes soft rot disease in various plants, including Chinese cabbage. The simple extracellular leucine-rich repeat (eLRR) domain proteins have been implicated in disease resistance. Rice leucine-rich repeat protein (OsLRP), a rice simple eLRR domain protein, is induced by pathogens, phytohormones, and salt. To see whether OsLRP enhances disease resistance to bacterial soft rot, OsLRP was introduced into Chinese cabbage by Agrobacterium-mediated transformation. Two independent transgenic lines over-expressing OsLRP were generated and further analyzed. Transgenic lines over-expressing OsLRP showed enhanced disease resistance to bacterial soft rot compared to non-transgenic control. Bacterial growth was retarded in transgenic lines over-expressing OsLRP compared to non-transgenic controls. We propose that OsLRP confers enhanced resistance to bacterial soft rot. Monitoring expression of defense-associated genes in transgenic lines over-expressing OsLRP, two different glucanases and Brassica rapa polygalacturonase inhibiting protein 2, PDF1 were constitutively activated in transgenic lines compared to non-transgenic control. Taken together, heterologous expression of OsLRP results in the activation of defense response and enhanced resistance to bacterial soft rot.

  19. Probability distributions of continuous measurement results for conditioned quantum evolution

    Science.gov (United States)

    Franquet, A.; Nazarov, Yuli V.

    2017-02-01

    We address the statistics of continuous weak linear measurement on a few-state quantum system that is subject to a conditioned quantum evolution. For a conditioned evolution, both the initial and final states of the system are fixed: the latter is achieved by the postselection in the end of the evolution. The statistics may drastically differ from the nonconditioned case, and the interference between initial and final states can be observed in the probability distributions of measurement outcomes as well as in the average values exceeding the conventional range of nonconditioned averages. We develop a proper formalism to compute the distributions of measurement outcomes, and evaluate and discuss the distributions in experimentally relevant setups. We demonstrate the manifestations of the interference between initial and final states in various regimes. We consider analytically simple examples of nontrivial probability distributions. We reveal peaks (or dips) at half-quantized values of the measurement outputs. We discuss in detail the case of zero overlap between initial and final states demonstrating anomalously big average outputs and sudden jump in time-integrated output. We present and discuss the numerical evaluation of the probability distribution aiming at extending the analytical results and describing a realistic experimental situation of a qubit in the regime of resonant fluorescence.

  20. Short and long term measures of anxiety exhibit opposite results.

    Directory of Open Access Journals (Sweden)

    Ehud Fonio

    Full Text Available Animal models of human diseases of the central nervous system, generalized anxiety disorder included, are essential for the study of the brain-behavior interface and obligatory for drug development; yet, these models fail to yield new insights and efficacious drugs. By increasing testing duration hundredfold and arena size tenfold, and comparing the behavior of the common animal model to that of wild mice, we raise concerns that chronic anxiety might have been measured at the wrong time, for the wrong duration, and in the wrong animal. Furthermore, the mice start the experimental session with a short period of transient adaptation to the novel environment (habituation period and a long period reflecting the respective trait of the mice. Using common measures of anxiety reveals that mice exhibit opposite results during these periods suggesting that chronic anxiety should be measured during the post-habituation period. We recommend tools for measuring the transient period, and provide suggestions for characterizing the post habituation period.

  1. Assessing atrophy measurement techniques in dementia: Results from the MIRIAD atrophy challenge

    Science.gov (United States)

    Cash, David M.; Frost, Chris; Iheme, Leonardo O.; Ünay, Devrim; Kandemir, Melek; Fripp, Jurgen; Salvado, Olivier; Bourgeat, Pierrick; Reuter, Martin; Fischl, Bruce; Lorenzi, Marco; Frisoni, Giovanni B.; Pennec, Xavier; Pierson, Ronald K.; Gunter, Jeffrey L.; Senjem, Matthew L.; Jack, Clifford R.; Guizard, Nicolas; Fonov, Vladimir S.; Collins, D. Louis; Modat, Marc; Cardoso, M. Jorge; Leung, Kelvin K.; Wang, Hongzhi; Das, Sandhitsu R.; Yushkevich, Paul A.; Malone, Ian B.; Fox, Nick C.; Schott, Jonathan M.; Ourselin, Sebastien

    2015-01-01

    Structural MRI is widely used for investigating brain atrophy in many neurodegenerative disorders, with several research groups developing and publishing techniques to provide quantitative assessments of this longitudinal change. Often techniques are compared through computation of required sample size estimates for future clinical trials. However interpretation of such comparisons is rendered complex because, despite using the same publicly available cohorts, the various techniques have been assessed with different data exclusions and different statistical analysis models. We created the MIRIAD atrophy challenge in order to test various capabilities of atrophy measurement techniques. The data consisted of 69 subjects (46 Alzheimer's disease, 23 control) who were scanned multiple (up to twelve) times at nine visits over a follow-up period of one to two years, resulting in 708 total image sets. Nine participating groups from 6 countries completed the challenge by providing volumetric measurements of key structures (whole brain, lateral ventricle, left and right hippocampi) for each dataset and atrophy measurements of these structures for each time point pair (both forward and backward) of a given subject. From these results, we formally compared techniques using exactly the same dataset. First, we assessed the repeatability of each technique using rates obtained from short intervals where no measurable atrophy is expected. For those measures that provided direct measures of atrophy between pairs of images, we also assessed symmetry and transitivity. Then, we performed a statistical analysis in a consistent manner using linear mixed effect models. The models, one for repeated measures of volume made at multiple time-points and a second for repeated “direct” measures of change in brain volume, appropriately allowed for the correlation between measures made on the same subject and were shown to fit the data well. From these models, we obtained estimates of the

  2. Assessing atrophy measurement techniques in dementia: Results from the MIRIAD atrophy challenge.

    Science.gov (United States)

    Cash, David M; Frost, Chris; Iheme, Leonardo O; Ünay, Devrim; Kandemir, Melek; Fripp, Jurgen; Salvado, Olivier; Bourgeat, Pierrick; Reuter, Martin; Fischl, Bruce; Lorenzi, Marco; Frisoni, Giovanni B; Pennec, Xavier; Pierson, Ronald K; Gunter, Jeffrey L; Senjem, Matthew L; Jack, Clifford R; Guizard, Nicolas; Fonov, Vladimir S; Collins, D Louis; Modat, Marc; Cardoso, M Jorge; Leung, Kelvin K; Wang, Hongzhi; Das, Sandhitsu R; Yushkevich, Paul A; Malone, Ian B; Fox, Nick C; Schott, Jonathan M; Ourselin, Sebastien

    2015-12-01

    Structural MRI is widely used for investigating brain atrophy in many neurodegenerative disorders, with several research groups developing and publishing techniques to provide quantitative assessments of this longitudinal change. Often techniques are compared through computation of required sample size estimates for future clinical trials. However interpretation of such comparisons is rendered complex because, despite using the same publicly available cohorts, the various techniques have been assessed with different data exclusions and different statistical analysis models. We created the MIRIAD atrophy challenge in order to test various capabilities of atrophy measurement techniques. The data consisted of 69 subjects (46 Alzheimer's disease, 23 control) who were scanned multiple (up to twelve) times at nine visits over a follow-up period of one to two years, resulting in 708 total image sets. Nine participating groups from 6 countries completed the challenge by providing volumetric measurements of key structures (whole brain, lateral ventricle, left and right hippocampi) for each dataset and atrophy measurements of these structures for each time point pair (both forward and backward) of a given subject. From these results, we formally compared techniques using exactly the same dataset. First, we assessed the repeatability of each technique using rates obtained from short intervals where no measurable atrophy is expected. For those measures that provided direct measures of atrophy between pairs of images, we also assessed symmetry and transitivity. Then, we performed a statistical analysis in a consistent manner using linear mixed effect models. The models, one for repeated measures of volume made at multiple time-points and a second for repeated "direct" measures of change in brain volume, appropriately allowed for the correlation between measures made on the same subject and were shown to fit the data well. From these models, we obtained estimates of the

  3. Results from the BABAR Fully Inclusive Measurement of B? Xs?

    Energy Technology Data Exchange (ETDEWEB)

    Aubert, B.; Barate, R.; Boutigny, D.; Couderc, F.; Karyotakis, Y.; Lees, J.P.; Poireau, V.; Tisserand, V.; Zghiche, A.; /Annecy, LAPP; Grauges, E.; /Barcelona, IFAE; Palano, A.; Pappagallo, M.; Pompili, A.; /Bari U. /INFN, Bari; Chen, J.C.; Qi, N.D.; Rong, G.; Wang, P.; Zhu, Y.S.; /Beijing, Inst. High Energy Phys.; Eigen, G.; Ofte, I.; Stugu, B.

    2005-09-20

    We present preliminary results from a lepton-tagged fully-inclusive measurement of B {yields} X{sub s}{gamma} decays, where X{sub s} is any strange hadronic state. Results are based on a BABAR data set of 88.5 million B{bar B} pairs at the {Upsilon}(4S) resonance. We present a reconstructed photon energy spectrum in the {Upsilon}(4S) frame, and partial branching fractions above minimum reconstructed photon energies of 1.9, 2.0, 2.1 and 2.2 GeV. We then convert these to measurements of partial branching fractions and truncated first and second moments of the true photon energy distribution in the B rest frame, above the same minimum photon energy values. The full correlation matrices between the first and second moments are included to allow fitting to any parameterized theoretical calculation. We also measure the direct CP asymmetry {Alpha}{sub CP}(B {yields} X{sub s+d{gamma}}) (based on the charge of the tagging lepton) above a reconstructed photon energy of 2.2 GeV.

  4. Results from the BABAR Fully Inclusive Measurement of B? Xs?

    Energy Technology Data Exchange (ETDEWEB)

    Aubert, B.; Barate, R.; Boutigny, D.; Couderc, F.; Karyotakis, Y.; Lees, J.P.; Poireau, V.; Tisserand, V.; Zghiche, A.; /Annecy, LAPP; Grauges, E.; /Barcelona, IFAE; Palano, A.; Pappagallo, M.; Pompili, A.; /Bari U. /INFN, Bari; Chen, J.C.; Qi, N.D.; Rong, G.; Wang, P.; Zhu, Y.S.; /Beijing, Inst. High Energy Phys.; Eigen, G.; Ofte, I.; Stugu, B.

    2005-09-20

    We present preliminary results from a lepton-tagged fully-inclusive measurement of B {yields} X{sub s}{gamma} decays, where X{sub s} is any strange hadronic state. Results are based on a BABAR data set of 88.5 million B{bar B} pairs at the {Upsilon}(4S) resonance. We present a reconstructed photon energy spectrum in the {Upsilon}(4S) frame, and partial branching fractions above minimum reconstructed photon energies of 1.9, 2.0, 2.1 and 2.2 GeV. We then convert these to measurements of partial branching fractions and truncated first and second moments of the true photon energy distribution in the B rest frame, above the same minimum photon energy values. The full correlation matrices between the first and second moments are included to allow fitting to any parameterized theoretical calculation. We also measure the direct CP asymmetry {Alpha}{sub CP}(B {yields} X{sub s+d{gamma}}) (based on the charge of the tagging lepton) above a reconstructed photon energy of 2.2 GeV.

  5. Results from power quality measurements in Germany - An overview

    Energy Technology Data Exchange (ETDEWEB)

    Gerdes, G.J.; Santjer, F. [German Wind Energy Inst, Wilhelmshaven (Germany)

    1996-12-31

    Grid interferences caused by wind turbines (WT) are getting a severe problem in Germany with the fast increasing number of installed turbines. The wind energy capacity was doubled annually in the past three years. The actual situation and the plannings for the next years will lead to a situation, where high wind energy penetration will exercise a big influence on the power and voltage quality of local utility networks. Measurements performed in Germany according to a national guideline show a big variety in power quality performance of WT`s, which does affect the requirements for grid connection and thus the economical situation of wind energy projects to a large extent. The results from more than 25 power quality measurements will be discussed in this paper. 5 refs., 5 figs., 1 tab.

  6. Measuring 35S of Aerosol Sulfate: Techniques and First Results

    Science.gov (United States)

    Brothers, L. A.; Dominguez, G.; Bluen, B.; Corbin, A.; Abramian, A.; Thiemens, M. H.

    2007-12-01

    On a global and regional level, the cycling of sulfur in the environment has consequences for air quality, human health, and may contribute to global climate change. Due to its multiple oxidation states, the sulfur cycle is very complex and poorly understood. Stable isotopes are currently used to understand reaction pathways as well as sources and sinks of sulfurous compounds in the environment. Sulfur also has one short lived (τ1/2 ~87 d) radioactive isotope (35S) which is continuously made in the atmosphere by the cosmic ray spallation of argon, is then quickly oxidized to 35SO2 and enters the atmospheric sulfur cycle. The short-lived radioactive nature of this isotope of sulfur provides us with potentially powerful tracer for understanding the time scales at which sulfur is oxidized, deposited, and transported in the atmosphere and the deposition of atmospheric sulfate into rivers and water catchments. However, despite its potential, the use of 35S as a tracer of aerosol chemistry has not been fully exploited, Here we present details of instrumental set up for measuring 35S in aerosol sulfate and some preliminary results of measurements of 35S abundances in aerosols from Riverside (inland) and La Jolla (coastal) CA and discuss the sensitivity and limitations of the measurements in providing insights into day/night aerosol chemistry (Riverside) as well as the uptake of SO2 pollution in coastal environments by sea-salt aerosols. Also, we present preliminary results from measurement of sulfate in river water in Ecuador before and after precipitation events.

  7. Measuring systems of hard to get objects: problems with analysis of measurement results

    Science.gov (United States)

    Gilewska, Grazyna

    2005-02-01

    The problem accessibility of metrological parameters features of objects appeared in many measurements. Especially if it is biological object which parameters very often determined on the basis of indirect research. Accidental component predominate in forming of measurement results with very limited access to measurement objects. Every measuring process has a lot of conditions limiting its abilities to any way processing (e.g. increase number of measurement repetition to decrease random limiting error). It may be temporal, financial limitations, or in case of biological object, small volume of sample, influence measuring tool and observers on object, or whether fatigue effects e.g. at patient. It's taken listing difficulties into consideration author worked out and checked practical application of methods outlying observation reduction and next innovative methods of elimination measured data with excess variance to decrease of mean standard deviation of measured data, with limited aomunt of data and accepted level of confidence. Elaborated methods wee verified on the basis of measurement results of knee-joint width space got from radiographs. Measurements were carried out by indirectly method on the digital images of radiographs. Results of examination confirmed legitimacy to using of elaborated methodology and measurement procedures. Such methodology has special importance when standard scientific ways didn't bring expectations effects.

  8. Measurement results obtained from air quality monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Turzanski, P.K.; Beres, R. [Provincial Inspection of Environmental Protection, Cracow (Poland)

    1995-12-31

    An automatic system of air pollution monitoring operates in Cracow since 1991. The organization, assembling and start-up of the network is a result of joint efforts of the US Environmental Protection Agency and the Cracow environmental protection service. At present the automatic monitoring network is operated by the Provincial Inspection of Environmental Protection. There are in total seven stationary stations situated in Cracow to measure air pollution. These stations are supported continuously by one semi-mobile (transportable) station. It allows to modify periodically the area under investigation and therefore the 3-dimensional picture of creation and distribution of air pollutants within Cracow area could be more intelligible.

  9. Screening for ovarian cancer in women with varying levels of risk, using annual tests, results in high recall for repeat screening tests

    Directory of Open Access Journals (Sweden)

    Nobbenhuis Marielle AE

    2011-11-01

    Full Text Available Abstract Background We assessed ovarian cancer screening outcomes in women with a positive family history of ovarian cancer divided into a low-, moderate- or high-risk group for development of ovarian cancer. Methods 545 women with a positive family history of ovarian cancer referred to the Ovarian Screening Service at the Royal Marsden Hospital, London from January 2000- December 2008 were included. They were stratified into three risk-groups according to family history (high-, moderate- and low-risk of developing ovarian cancer and offered annual serum CA 125 and transvaginal ultrasound screening. The high-risk group was offered genetic testing. Results The median age at entry was 44 years. The number of women in the high, moderate and low-risk groups was 397, 112, and 36, respectively. During 2266 women years of follow-up two ovarian cancer cases were found: one advanced stage at her fourth annual screening, and one early stage at prophylactic bilateral salpingo-oophorectomy (BSO. Prophylactic BSO was performed in 138 women (25.3%. Forty-three women had an abnormal CA125, resulting in 59 repeat tests. The re-call rate in the high, moderate and low-risk group was 14%, 3% and 6%. Equivocal transvaginal ultrasound results required 108 recalls in 71 women. The re-call rate in the high, moderate, and low-risk group was 25%, 6% and 17%. Conclusion No early stage ovarian cancer was picked up at annual screening and a significant number of re-calls for repeat screening tests was identified.

  10. Neutrino measurements from the Sun and Earth: Results from Borexino

    Energy Technology Data Exchange (ETDEWEB)

    Bellini, G.; Caccianiga, B.; D’Angelo, D.; Giammarchi, M.; Lombardi, P.; Ludhova, L.; Meroni, E.; Miramonti, L.; Ranucci, G., E-mail: gioacchino.ranucci@mi.infn.it; Re, A. [Dipartimento di Fisica, Universitá degli Studi e INFN, 20133 Milano (Italy); Benziger, J. [Chemical Engineering Department, Princeton University, Princeton, New Jersey 08544 (United States); Bick, D.; Hagner, C.; Meyer, M. [Institut für Experimentalphysik, Universität Hamburg, 22761 Hamburg (Germany); Bonfini, G.; Cavalcante, P.; Gabriele, F.; Gazzana, S.; Ianni, Aldo; Laubenstein, M. [INFN Laboratori Nazionali del Gran Sasso, 67100 Assergi (Italy); and others

    2015-07-15

    Important neutrino results came recently from Borexino, a massive, calorimetric liquid scintillator detector installed at the underground Gran Sasso Laboratory. With its unprecedented radiopurity levels achieved in the core of the detection medium, it is the only experiment in operation able to study in real time solar neutrino interactions in the challenging sub-MeV energy region. The recently achieved breakthrough observation of the fundamental pp flux, the precise measurement of the {sup 7}Be solar neutrino flux, and the results concerning the pep, {sup 8}B and CNO fluxes, together with their physics implications, are described in this work. Moreover, the detector has also provided a clean detection of terrestrial neutrinos, from which they emerge as a new probe of the interior of the Earth.

  11. Recent Results of TMD Measurements from Jefferson Lab Hall A

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Xiaodong [LANL

    2013-10-01

    This slide-show presents results on transverse momentum distributions. The presentation covers: target single-spin asymmetry (SSA) (in parity conserving interactions); • Results of JLab Hall A polarized {sup 3}He target TMD measurement; • Semi-­inclusive deep-inelastic scattering channels (E06-010); • Target single-spin asymmetry A{sub UT}, Collins and Sivers SSA on neutron; • Double-spin asymmetry A{sub LT}, extract TMD g{sub 1T} on neutron; • Inclusive channels SSA (E06-010, E05-015, E07-013) • Target SSA: inclusive {sup 3}He(e,e’) quasi-elastic scattering; • Target SSA: inclusive {sup 3}He(e,e’) deep inelastic-elastic scattering; • New SIDIS experiments planned in Hall-A for JLab-12 GeV.

  12. Effects of ambient air pollution on functional status in patients with chronic congestive heart failure: a repeated-measures study

    Directory of Open Access Journals (Sweden)

    Phillips Russell S

    2007-09-01

    Full Text Available Abstract Background Studies using administrative data report a positive association between ambient air pollution and the risk of hospitalization for congestive heart failure (HF. Circulating levels of B-type natriuretic peptide (BNP are directly associated with cardiac hemodynamics and symptom severity in patients with HF and, therefore, serves as a marker of functional status. We tested the hypothesis that BNP levels would be positively associated with short-term changes in ambient pollution levels among 28 patients with chronic stable HF and impaired systolic function. Methods BNP was measured in whole blood at 0, 6, and 12 weeks. We used linear mixed models to evaluate the association between fine particulate matter (PM2.5, carbon monoxide, sulfur dioxide, nitrogen dioxide, ozone, and black carbon and log(BNP. Lags of 0 to 3 days were considered in separate models. We calculated the intraclass correlation coefficient and within-subject coefficient of variation as measures of reproducibility. Results We found no association between any pollutant and measures of BNP at any lag. For example, a 10 μg/m3 increase in PM2.5 was associated with a 0.8% (95% CI: -16.4, 21.5; p = 0.94 increase in BNP on the same day. The within-subject coefficient of variation was 45% on the natural scale and 9% on the log scale. Conclusion These results suggest that serial BNP measurements are unlikely to be useful in a longitudinal study of air pollution-related acute health effects. The magnitude of expected ambient air pollution health effects appears small in relation to the considerable within-person variability in BNP levels in this population.

  13. Fan Noise Source Diagnostic Test: LDV Measured Flow Field Results

    Science.gov (United States)

    Podboy, Gary C.; Krupar, Martin J.; Hughes, Christopher E.; Woodward, Richard P.

    2003-01-01

    Results are presented of an experiment conducted to investigate potential sources of noise in the flow developed by two 22-in. diameter turbofan models. The R4 and M5 rotors that were tested were designed to operate at nominal take-off speeds of 12,657 and 14,064 RPMC, respectively. Both fans were tested with a common set of swept stators installed downstream of the rotors. Detailed measurements of the flows generated by the two were made using a laser Doppler velocimeter system. The wake flows generated by the two rotors are illustrated through a series of contour plots. These show that the two wake flows are quite different, especially in the tip region. These data are used to explain some of the differences in the rotor/stator interaction noise generated by the two fan stages. In addition to these wake data, measurements were also made in the R4 rotor blade passages. These results illustrate the tip flow development within the blade passages, its migration downstream, and (at high rotor speeds) its merging with the blade wake of the adjacent (following) blade. Data also depict the variation of this tip flow with tip clearance. Data obtained within the rotor blade passages at high rotational speeds illustrate the variation of the mean shock position across the different blade passages.

  14. Deployment Repeatability

    Science.gov (United States)

    2016-04-01

    controlled to great precision, but in a Cubesat , there may be no attitude determination at all. Such a Cubesat might treat sun angle and tumbling rates as...could be sensitive to small differences in motor controller timing. In these cases, the analyst might choose to model the entire deployment path, with...knowledge of the material damage model or motor controller timing precision. On the other hand, if many repeated and environmentally representative

  15. Analyzing repeated data collected by mobile phones and frequent text messages. An example of Low back pain measured weekly for 18 weeks

    Directory of Open Access Journals (Sweden)

    Axén Iben

    2012-07-01

    Full Text Available Abstract Background Repeated data collection is desirable when monitoring fluctuating conditions. Mobile phones can be used to gather such data from large groups of respondents by sending and receiving frequently repeated short questions and answers as text messages. The analysis of repeated data involves some challenges. Vital issues to consider are the within-subject correlation, the between measurement occasion correlation and the presence of missing values. The overall aim of this commentary is to describe different methods of analyzing repeated data. It is meant to give an overview for the clinical researcher in order for complex outcome measures to be interpreted in a clinically meaningful way. Methods A model data set was formed using data from two clinical studies, where patients with low back pain were followed with weekly text messages for 18 weeks. Different research questions and analytic approaches were illustrated and discussed, as well as the handling of missing data. In the applications the weekly outcome “number of days with pain” was analyzed in relation to the patients’ “previous duration of pain” (categorized as more or less than 30 days in the previous year. Research questions with appropriate analytical methods 1: How many days with pain do patients experience? This question was answered with data summaries. 2: What is the proportion of participants “recovered” at a specific time point? This question was answered using logistic regression analysis. 3: What is the time to recovery? This question was answered using survival analysis, illustrated in Kaplan-Meier curves, Proportional Hazard regression analyses and spline regression analyses. 4: How is the repeatedly measured data associated with baseline (predictor variables? This question was answered using generalized Estimating Equations, Poisson regression and Mixed linear models analyses. 5: Are there subgroups of patients with similar courses of pain

  16. The results of surgical treatment of 14 patients underwent repeated tricuspid valve operations%三尖瓣再次手术14例

    Institute of Scientific and Technical Information of China (English)

    周明阳; 张健群; 孟旭; 李温斌; 孔晴宇

    2008-01-01

    目的 总结三尖瓣再次手术的治疗效果及经验.方法 2002年至2006年,收治14例三尖瓣再次手术病人,其中三尖瓣成形术后再次出现关闭不全12例,三尖瓣置换术后人工瓣膜功能障碍2例.结果 再次实施三尖瓣成形术5例,三尖瓣置换术9例.死亡2例,余者治愈出院.10例随访2~40个月,1例心功能Ⅲ级,余者均为Ⅰ~Ⅱ级.结论 再次三尖瓣手术治疗效果确切,手术死亡与手术方式的选择以及围术期心、肾功能衰竭有关.%Objective To evaluate the results and surgical treatment of the repeated tricuspid valve operations. Methods The hospital records was reviewed for 14 patients who underwent repeated tricuspid valve operations between 2003 and 2006, including 12 patients with tricuspid regurgitation received first tricuspid valve repair and 2 patients, with prosthetic valve dysfunction. Results Reoperations of tricuspid valve included 5 tricuspid valve repair and 9 tricuspid valve replacement. There were two postoperative deaths. Post-operative heart function (NYHA) was improved significantly, 1 case in Ⅲ and 9 in Ⅰ-Ⅱ. Ten survivors were followed up for 2 - 40 months. Conclusion Tricuspid valve reoperations may be performed with acceptable operative mortality. Perioperative death was associated with surgical methods and heart or renal function failure.

  17. Simulated Conversations With Virtual Humans to Improve Patient-Provider Communication and Reduce Unnecessary Prescriptions for Antibiotics: A Repeated Measure Pilot Study

    Science.gov (United States)

    2017-01-01

    Background Despite clear evidence that antibiotics do not cure viral infections, the problem of unnecessary prescribing of antibiotics in ambulatory care persists, and in some cases, prescribing patterns have increased. The overuse of antibiotics for treating viral infections has created numerous economic and clinical consequences including increased medical costs due to unnecessary hospitalizations, antibiotic resistance, disruption of gut bacteria, and obesity. Recent research has underscored the importance of collaborative patient-provider communication as a means to reduce the high rates of unnecessary prescriptions for antibiotics. However, most patients and providers do not feel prepared to engage in such challenging conversations. Objectives The aim of this pilot study was to assess the ability of a brief 15-min simulated role-play conversation with virtual humans to serve as a preliminary step to help health care providers and patients practice, and learn how to engage in effective conversations about antibiotics overuse. Methods A total of 69 participants (35 providers and 34 patients) completed the simulation once in one sitting. A pre-post repeated measures design was used to assess changes in patients’ and providers’ self-reported communication behaviors, activation, and preparedness, intention, and confidence to effectively communicate in the patient-provider encounter. Changes in patients’ knowledge and beliefs regarding antibiotic use were also evaluated. Results Patients experienced a short-term positive improvement in beliefs about appropriate antibiotic use for infection (F1,30=14.10, P=.001). Knowledge scores regarding the correct uses of antibiotics improved immediately postsimulation, but decreased at the 1-month follow-up (F1,30=31.16, P.10) Patients with lower levels of activation exhibited positive, short-term benefits in increased intent and confidence to discuss their needs and ask questions in the clinic visit, positive attitudes

  18. Election results of Southwest ballot measures affecting healthcare

    Directory of Open Access Journals (Sweden)

    Robbins RA

    2016-11-01

    Full Text Available No abstract available. Article truncated after 150 words. Earlier this week an article was posted listing Southwest ballot measures that affect healthcare. Below are the results obtained from various internet sources. States: Arizona: 1. Recreational marijuana. Proposition 205: Legalizes recreational marijuana use for people 21 and older. Opponents of the measure include the Arizona Health and Hospital Association and Insys Therapeutics, a company that makes a cannabis-based pain medication. Defeated: Yes 929,518 (48% No 1,011,836 (52%. California 1.Medi-Cal hospital fee program. Proposition 52: Requires the legislature to get voter approval to use fee revenue for purposes other than generating federal matching funds and funding enhanced Medicaid payments and grants for hospitals. The initiative, which was written by the California Hospital Association and is supported by most state lawmakers, would also make the program permanent, requiring a supermajority in the legislature to end it. Passed: Yes 5,950,642 (70% No 2,599,764 (30%. 2. Tobacco tax. Proposition 56: Increases the ...

  19. Using the American alligator and a repeated-measures design to place constraints on in vivo shoulder joint range of motion in dinosaurs and other fossil archosaurs.

    Science.gov (United States)

    Hutson, Joel D; Hutson, Kelda N

    2013-01-15

    Using the extant phylogenetic bracket of dinosaurs (crocodylians and birds), recent work has reported that elbow joint range of motion (ROM) studies of fossil dinosaur forearms may be providing conservative underestimates of fully fleshed in vivo ROM. As humeral ROM occupies a more central role in forelimb movements, the placement of quantitative constraints on shoulder joint ROM could improve fossil reconstructions. Here, we investigated whether soft tissues affect the more mobile shoulder joint in the same manner in which they affect elbow joint ROM in an extant archosaur. This test involved separately and repeatedly measuring humeral ROM in Alligator mississippiensis as soft tissues were dissected away in stages to bare bone. Our data show that the ROMs of humeral flexion and extension, as well as abduction and adduction, both show a statistically significant increase as flesh is removed, but then decrease when the bones must be physically articulated and moved until they separate from one another and/or visible joint surfaces. A similar ROM pattern is inferred for humeral pronation and supination. All final skeletonized ROMs were less than initial fully fleshed ROMs. These results are consistent with previously reported elbow joint ROM patterns from the extant phylogenetic bracket of dinosaurs. Thus, studies that avoid separation of complementary articular surfaces may be providing fossil shoulder joint ROMs that underestimate in vivo ROM in dinosaurs, as well as other fossil archosaurs.

  20. Hysteresis of magnetostructural transitions: Repeatable and non-repeatable processes

    Energy Technology Data Exchange (ETDEWEB)

    Provenzano, Virgil [National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States); Della Torre, Edward; Bennett, Lawrence H. [Department of Electrical and Computer Engineering, The George Washington University, Washington, DC 20052 (United States); ElBidweihy, Hatem, E-mail: Hatem@gwmail.gwu.edu [Department of Electrical and Computer Engineering, The George Washington University, Washington, DC 20052 (United States)

    2014-02-15

    The Gd{sub 5}Ge{sub 2}Si{sub 2} alloy and the off-stoichiometric Ni{sub 50}Mn{sub 35}In{sub 15} Heusler alloy belong to a special class of metallic materials that exhibit first-order magnetostructural transitions near room temperature. The magnetic properties of this class of materials have been extensively studied due to their interesting magnetic behavior and their potential for a number of technological applications such as refrigerants for near-room-temperature magnetic refrigeration. The thermally driven first-order transitions in these materials can be field-induced in the reverse order by applying a strong enough field. The field-induced transitions are typically accompanied by the presence of large magnetic hysteresis, the characteristics of which are a complicated function of temperature, field, and magneto-thermal history. In this study we show that the virgin curve, the major loop, and sequentially measured MH loops are the results of both repeatable and non-repeatable processes, in which the starting magnetostructural state, prior to the cycling of field, plays a major role. Using the Gd{sub 5}Ge{sub 2}Si{sub 2} and Ni{sub 50}Mn{sub 35}In{sub 15} alloys, as model materials, we show that a starting single phase state results in fully repeatable processes and large magnetic hysteresis, whereas a mixed phase starting state results in non-repeatable processes and smaller hysteresis.

  1. Measuring spiral arm torques results for M100

    CERN Document Server

    Gnedin, O Y; Frei, Z; Gnedin, Oleg Y; Goodman, Jeremy; Frei, Zsolt

    1995-01-01

    Spiral arms, if they are massive, exert gravitational torques that transport angular momentum radially within galactic disks. These torques depend not on the pattern speed or permanence of the arms but only on the nonaxisymmetric mass distribution. Hence the torques can be measured from photometry. We demonstrate this using gri CCD data for M100 (NGC 4321). Since we find consistency among the three bands, we believe that dust and young stars in the arms do not seriously bias our results. If the present epoch is representative, the timescale for redistribution of angular momentum in M100 is 5-10 Gyr, the main uncertainty being the mass-to-light ratio of the disk.

  2. Evaluation of Multiple Imputation in Missing Data Analysis: An Application on Repeated Measurement Data in Animal Science

    Directory of Open Access Journals (Sweden)

    Gazel Ser

    2015-12-01

    Full Text Available The purpose of this study was to evaluate the performance of multiple imputation method in case that missing observation structure is at random and completely at random from the approach of general linear mixed model. The application data of study was consisted of a total 77 heads of Norduz ram lambs at 7 months of age. After slaughtering, pH values measured at five different time points were determined as dependent variable. In addition, hot carcass weight, muscle glycogen level and fasting durations were included as independent variables in the model. In the dependent variable without missing observation, two missing observation structures including Missing Completely at Random (MCAR and Missing at Random (MAR were created by deleting the observations at certain rations (10% and 25%. After that, in data sets that have missing observation structure, complete data sets were obtained using MI (multiple imputation. The results obtained by applying general linear mixed model to the data sets that were completed using MI method were compared to the results regarding complete data. In the mixed model which was applied to the complete data and MI data sets, results whose covariance structures were the same and parameter estimations and standard estimations were rather close to the complete data are obtained. As a result, in this study, it was ensured that reliable information was obtained in mixed model in case of choosing MI as imputation method in missing observation structure and rates of both cases.

  3. Repeatability and Reproducibility of Retinal Nerve Fiber Layer Parameters Measured by Scanning Laser Polarimetry with Enhanced Corneal Compensation in Normal and Glaucomatous Eyes.

    Science.gov (United States)

    Ara, Mirian; Ferreras, Antonio; Pajarin, Ana B; Calvo, Pilar; Figus, Michele; Frezzotti, Paolo

    2015-01-01

    To assess the intrasession repeatability and intersession reproducibility of peripapillary retinal nerve fiber layer (RNFL) thickness parameters measured by scanning laser polarimetry (SLP) with enhanced corneal compensation (ECC) in healthy and glaucomatous eyes. One randomly selected eye of 82 healthy individuals and 60 glaucoma subjects was evaluated. Three scans were acquired during the first visit to evaluate intravisit repeatability. A different operator obtained two additional scans within 2 months after the first session to determine intervisit reproducibility. The intraclass correlation coefficient (ICC), coefficient of variation (COV), and test-retest variability (TRT) were calculated for all SLP parameters in both groups. ICCs ranged from 0.920 to 0.982 for intravisit measurements and from 0.910 to 0.978 for intervisit measurements. The temporal-superior-nasal-inferior-temporal (TSNIT) average was the highest (0.967 and 0.946) in normal eyes, while nerve fiber indicator (NFI; 0.982) and inferior average (0.978) yielded the best ICC in glaucomatous eyes for intravisit and intervisit measurements, respectively. All COVs were under 10% in both groups, except NFI. TSNIT average had the lowest COV (2.43%) in either type of measurement. Intervisit TRT ranged from 6.48 to 12.84. The reproducibility of peripapillary RNFL measurements obtained with SLP-ECC was excellent, indicating that SLP-ECC is sufficiently accurate for monitoring glaucoma progression.

  4. A database for storing the results of material radiopurity measurements

    Science.gov (United States)

    Loach, J. C.; Cooley, J.; Cox, G. A.; Li, Z.; Nguyen, K. D.; Poon, A. W. P.

    2016-12-01

    Searches for rare nuclear processes, such as neutrinoless double beta-decay and the interactions of WIMP dark matter, are motivating experiments with ever-decreasing levels of radioactive backgrounds. These background reductions are achieved using various techniques, but amongst the most important is minimizing radioactive contamination in the materials from which the experiment is constructed. To this end there have been decades of advances in material sourcing, manufacture and certification, during which researchers have accumulated many thousands of measurements of material radiopurity. Some of these assays are described in publications, others are in databases, but many are still communicated informally. Until this work, there has been no standard format for encoding assay results and no effective, central location for storing them. The aim of this work is to address these long-standing problems by creating a concise and flexible material assay data format and powerful software application to manipulate it. A public installation of this software, available at http://www.radiopurity.org, is the largest database of assay results ever compiled and is intended as a long-term repository for the community's data.

  5. Results of Sexbierum Wind Farm: single wake measurements

    NARCIS (Netherlands)

    Cleijne, J.W.

    1993-01-01

    In the framework of the JOULE-0064 'Full-scale Measurements in Wind Turbine Arrays' in the period between June-November 1992 measurements have been performed in the Sexbierum Wind Farm. The aim of the measurements is to provide data for the validation of wake and wind farm models, which are being de

  6. Results from laboratory and field testing of nitrate measuring spectrophotometers

    Science.gov (United States)

    Snazelle, Teri T.

    2015-01-01

    Five ultraviolet (UV) spectrophotometer nitrate analyzers were evaluated by the U.S. Geological Survey (USGS) Hydrologic Instrumentation Facility (HIF) during a two-phase evaluation. In Phase I, the TriOS ProPs (10-millimeter (mm) path length), Hach NITRATAX plus sc (5-mm path length), Satlantic Submersible UV Nitrate Analyzer (SUNA, 10-mm path length), and S::CAN Spectro::lyser (5-mm path length) were evaluated in the HIF Water-Quality Servicing Laboratory to determine the validity of the manufacturer's technical specifications for accuracy, limit of linearity (LOL), drift, and range of operating temperature. Accuracy specifications were met in the TriOS, Hach, and SUNA. The stock calibration of the S::CAN required two offset adjustments before the analyzer met the manufacturer's accuracy specification. Instrument drift was observed only in the S::CAN and was the result of leaching from the optical path insert seals. All tested models, except for the Hach, met their specified LOL in the laboratory testing. The Hach's range was found to be approximately 18 milligrams nitrogen per liter (mg-N/L) and not the manufacturer-specified 25 mg-N/L. Measurements by all of the tested analyzers showed signs of hysteresis in the operating temperature tests. Only the SUNA measurements demonstrated excessive noise and instability in temperatures above 20 degrees Celsius (°C). The SUNA analyzer was returned to the manufacturer at the completion of the Phase II field deployment evaluation for repair and recalibration, and the performance of the sensor improved significantly.

  7. [Changes in knowledge, attitudes, and smoking behavior among young people in Germany. Results of repeated, representative surveys by the BZgA].

    Science.gov (United States)

    Orth, B; Töppich, J

    2010-02-01

    Following an increase in tobacco consumption among 12 to 17 year olds between 1993 and 1997, a policy mix comprising various structural and behavioral prevention measures was implemented in Germany. One element of this policy mix is the "rauchfrei" ("smoke-free") youth campaign of the BZgA (Federal Centre for Health Education), a combination of media that reaches a large number of youth, personal communication, and setting-based interventions. The aim is to prevent young people from starting to smoke and to promote the cessation of smoking at an early stage. Based on a multistage intervention model, wide coverage of the measures should be achieved among young people, as well as changes in knowledge, attitudes, social norms, and behavioral intentions. Based on the intervention model, repeated, representative cross-sectional surveys were conducted to examine the development of these indicators and of tobacco consumption. Five studies were conducted during the period from 2003 to 2008, each comprising between 1,220 and 2,780 computer-assisted telephone interviews with randomly selected young people between the ages of 12 and 17. The percentage of young people reached by information offered on the subject of not smoking rose between 2003 and 2008. Participation in school-based prevention measures also rose. There was an increase in knowledge regarding the harmful substances contained in cigarette smoke, and in the percentage of young people who rated active and passive smoking as being harmful to health. In addition, the attitude towards smoking of young people who have never smoked became more critical, as did that perceived in the social environment. The proportion of young people who smoke declined substantially, from 27.5% (2001) to 15.4% (2008), and there was been a major rise in the number who have never smoked, from 40.5% (2001) to 60.6% (2008). The change in knowledge-based risk assessments, attitudes, and social norms should be further promoted by mass media

  8. Reconfigurable multiport EPON repeater

    Science.gov (United States)

    Oishi, Masayuki; Inohara, Ryo; Agata, Akira; Horiuchi, Yukio

    2009-11-01

    An extended reach EPON repeater is one of the solutions to effectively expand FTTH service areas. In this paper, we propose a reconfigurable multi-port EPON repeater for effective accommodation of multiple ODNs with a single OLT line card. The proposed repeater, which has multi-ports in both OLT and ODN sides, consists of TRs, BTRs with the CDR function and a reconfigurable electrical matrix switch, can accommodate multiple ODNs to a single OLT line card by controlling the connection of the matrix switch. Although conventional EPON repeaters require full OLT line cards to accommodate subscribers from the initial installation stage, the proposed repeater can dramatically reduce the number of required line cards especially when the number of subscribers is less than a half of the maximum registerable users per OLT. Numerical calculation results show that the extended reach EPON system with the proposed EPON repeater can save 17.5% of the initial installation cost compared with a conventional repeater, and can be less expensive than conventional systems up to the maximum subscribers especially when the percentage of ODNs in lightly-populated areas is higher.

  9. Measurement of ability emotional intelligence: results for two new tests.

    Science.gov (United States)

    Austin, Elizabeth J

    2010-08-01

    Emotional intelligence (EI) has attracted considerable interest amongst both individual differences researchers and those in other areas of psychology who are interested in how EI relates to criteria such as well-being and career success. Both trait (self-report) and ability EI measures have been developed; the focus of this paper is on ability EI. The associations of two new ability EI tests with psychometric intelligence, emotion perception, and the Mayer-Salovey-Caruso EI test (MSCEIT) were examined. The new EI tests were the Situational Test of Emotion Management (STEM) and the Situational Test of Emotional Understanding (STEU). Only the STEU and the MSCEIT Understanding Emotions branch were significantly correlated with psychometric intelligence, suggesting that only understanding emotions can be regarded as a candidate new intelligence component. These understanding emotions tests were also positively correlated with emotion perception tests, and STEM and STEU scores were positively correlated with MSCEIT total score and most branch scores. Neither the STEM nor the STEU were significantly correlated with trait EI tests, confirming the distinctness of trait and ability EI. Taking the present results as a starting-point, approaches to the development of new ability EI tests and models of EI are suggested.

  10. Tunka-Rex: Status and results of the first measurements

    Energy Technology Data Exchange (ETDEWEB)

    Kostunin, D., E-mail: dmitriy.kostunin@kit.edu [Institut für Kernphysik, Karlsruhe Institute of Technology (KIT) (Germany); Budnev, N.M.; Gress, O.A. [Institute of Applied Physics ISU, Irkutsk (Russian Federation); Haungs, A.; Hiller, R.; Huege, T. [Institut für Kernphysik, Karlsruhe Institute of Technology (KIT) (Germany); Kazarina, Y. [Institute of Applied Physics ISU, Irkutsk (Russian Federation); Kleifges, M. [Institut für Prozessdatenverarbeitung und Elektronik, Karlsruhe Institute of Technology (KIT) (Germany); Konstantinov, A. [Skobeltsyn Institute of Nuclear Physics MSU, Moscow (Russian Federation); Konstantinov, E.N. [Institute of Applied Physics ISU, Irkutsk (Russian Federation); Korosteleva, E.E. [Skobeltsyn Institute of Nuclear Physics MSU, Moscow (Russian Federation); Krömer, O. [Institut für Prozessdatenverarbeitung und Elektronik, Karlsruhe Institute of Technology (KIT) (Germany); Kuzmichev, L.A. [Skobeltsyn Institute of Nuclear Physics MSU, Moscow (Russian Federation); Mirgazov, R.R.; Pankov, L. [Institute of Applied Physics ISU, Irkutsk (Russian Federation); Prosin, V.V. [Skobeltsyn Institute of Nuclear Physics MSU, Moscow (Russian Federation); Rubtsov, G.I. [Institute for Nuclear Research of the Russian Academy of Sciences, Moscow (Russian Federation); Rühle, C. [Institut für Prozessdatenverarbeitung und Elektronik, Karlsruhe Institute of Technology (KIT) (Germany); Schröder, F.G. [Institut für Kernphysik, Karlsruhe Institute of Technology (KIT) (Germany); Svetnitsky, E. [Institute of Applied Physics ISU, Irkutsk (Russian Federation); and others

    2014-04-01

    Tunka-Rex is the new radio extension of Tunka-133 located in Siberia close to Lake Baikal. The latter is a photomultiplier array registering air-Cherenkov light from air showers induced by cosmic-ray particles with initial energies of approximately 10{sup 16}–10{sup 18}eV. Tunka-Rex extends this detector with 25 antennas spread over an area of 1 km{sup 2}. It is triggered externally by Tunka-133, and detects the radio emission of the same air showers. The combination of an air-Cherenkov and a radio detector provides a facility for hybrid measurements and cross-calibration between the two techniques. The main goal of Tunka-Rex is to determine the precision of the reconstruction of air-shower parameters using the radio detection technique. It started operation in autumn 2012. We present the overall concept of Tunka-Rex, the current status of the array and first analysis results.

  11. Subjectivity of LiDAR-Based Offset Measurements: Results from a Public Online Survey

    Science.gov (United States)

    Salisbury, J. B.; Arrowsmith, R.; Rockwell, T. K.; Haddad, D. E.; Zielke, O.; Madden, C.

    2012-12-01

    Geomorphic features (e.g., stream channels) that are offset in an earthquake can be measured to determine slip at that location. Analysis of these and other offset features can provide useful information for generating fault slip distributions. Remote analyses of active fault zones using high-resolution LiDAR data have recently been pursued in several studies, but there is a lack of consistency between users both for data analysis and results reporting. Individual investigators typically make offset measurements in a particular study area with their own protocols for measurement, assessing uncertainty, and quality rating, yet there is no coherent understanding of the reliability and repeatability of the measurements from observer to observer. We invited the participation of colleagues, interested geoscience communities, and the general public to measure ten geomorphic offsets from active faults in western North America using remote measurement methods that span a range of complexity (e.g., paper image and scale, the Google Earth ruler tool, and a MATLAB GUI for calculating backslip required to properly restore tectonic deformation) to explore the subjectivity involved with measuring geomorphic offsets. We provided a semi-quantitative quality-rating rubric for a description of offset quality, but there was a general lack of quality rating/offset uncertainty reporting. Survey responses (including mapped fault traces and piercing lines) were anonymously submitted along with user experience information. We received 11 paper-, 28 Google Earth-, and 16 MATLAB-based survey responses, though not all individuals measured every feature provided. For all survey methods, the majority of responses are in close agreement. However, large discrepancies arise where users interpret landforms differently, specifically the pre-earthquake morphologies and total offset accumulation of geomorphic features. Experienced users make more consistent measurements, whereas beginners less

  12. Diagonalization and representation results for nonpositive sesquilinear form measures

    Science.gov (United States)

    Hytönen, Tuomas; Pellonpää, Juha-Pekka; Ylinen, Kari

    2008-02-01

    We study decompositions of operator measures and more general sesquilinear form measures E into linear combinations of positive parts, and their diagonal vector expansions. The underlying philosophy is to represent E as a trace class valued measure of bounded variation on a new Hilbert space related to E. The choice of the auxiliary Hilbert space fixes a unique decomposition with certain properties, but this choice itself is not canonical. We present relations to Naimark type dilations and direct integrals.

  13. Isolated systems with wind power. Results of measurements in Egypt

    DEFF Research Database (Denmark)

    Bindner, Henrik W.; Saleh, L.; Hafiez, S.A.;

    2001-01-01

    The objective of the measurements were to characterise different types of consumer loads in order to be able to construct load patterns to be used in feasibility studies where the available data often will be incomplete, not available or not existing. Measurements have been carried out at five di...

  14. Repeated-Sprint Cycling Does Not Induce Respiratory Muscle Fatigue in Active Adults: Measurements from The Powerbreathe® Inspiratory Muscle Trainer

    Directory of Open Access Journals (Sweden)

    Clare Minahan, Beth Sheehan, Rachel Doutreband, Tom Kirkwood, Daniel Reeves, Troy Cross

    2015-03-01

    Full Text Available This study examined respiratory muscle strength using the POWERbreathe® inspiratory muscle trainer (i.e., ‘S-Index’ before and after repeated-sprint cycling for comparison with maximal inspiratory pressure (MIP values obtained during a Mueller maneuver. The S-Index was measured during six trials across two sessions using the POWERbreathe® and MIP was measured during three trials in a single session using a custom-made manometer in seven recreationally active adults. Global respiratory muscle strength was measured using both devices before and after the performance of sixteen, 6-s sprints on a cycle ergometer. Intraclass correlation coefficients for the POWERbreathe® S-index indicated excellent (p 0.99 and during the Mueller maneuver (p > 0.99. The POWERbreathe® S-Index is a moderately reliable, but not equivalent, measure of MIP determined during a Mueller maneuver. Furthermore, repeated-sprint cycling does not induce globalized respiratory muscle fatigue in recreationally-active adults.

  15. Repeatability of measurements of packed cell volume and egg count as indicators of endoparasite load and their relationship with sheep productivity.

    Science.gov (United States)

    Bekele, T; Kasali, O B; Rege, J E

    1991-12-01

    Monthly measurements of packed cell volume (PCV) and nematode and trematode eggs per gram (EPG) were made in Ethiopian highland sheep at Debre Berhan, Dejen, Deneba, Tulu Meko and Wereilu from June 1988 to December 1989. High frequencies of low PCV, high nematode EPG and high trematode EPG were found at Tulu Meko. Among the productivity traits examined, body condition scores and live-weights were significantly (P less than 0.05) associated with differences in PCV and nematode and trematode EPG levels at most sites. The lambing interval was, however, not significantly (P greater than 0.05) affected by these variables. Monthly repeatabilities of PCV, body weight and body condition scores were 0.44 +/- 0.01, 0.71 +/- 0.01 and 0.35 +/- 0.01, respectively, while those of nematode (0.09 +/- 0.01) and trematode EPGs (0.20 +/- 0.02) were much lower. The high repeatability for PCV indicates that it was less affected by the variable factors influencing egg output, and hence it could be utilized in conjunction with nematode and trematode EPG levels for endoparasite monitoring. Repeatability of the lambing interval across parities was 0.43 +/- 0.14.

  16. Very long Detection Times after High and repeated intake of Heroin and Methadone, measured in Oral Fluid

    Directory of Open Access Journals (Sweden)

    Vindenes V.

    2014-12-01

    Full Text Available When detection times for psychoactive drugs in oral fluid are reported, they are most often based on therapeutic doses administered in clinical studies. Repeated ingestions of high doses, as seen after drug abuse, are however likely to cause positive samples for extended time periods. Findings of drugs of abuse in oral fluid might lead to negative sanctions, and the knowledge of detection times of these drugs are important to ensure correct interpretation. The aim of this study was to investigate the detection times of opioids in oral fluid. 25 patients with a history of heavy drug abuse admitted to a detoxification ward were included. Oral fluid and urine were collected daily and, if the patient gave consent, a blood sample was drawn during the first five days after admission. Morphine, codeine and/or 6-monoacetyl morphine (6-MAM were found in oral fluid and/or urine from 20 patients. The maximum detection times in oral fluid for codeine, morphine and 6-MAM were 1, 3 and 8 days, respectively. Positive oral fluid samples were interspersed with negative samples, mainly for concentrations around cut off. Elimination curves for methadone in oral fluid were found for two subjects, and the detection times were 5 and 8 days. Oral fluid is likely to become a good method for detection of drug abuse in the future

  17. Bayesian hierarchical joint modeling of repeatedly measured continuous and ordinal markers of disease severity: Application to Ugandan diabetes data.

    Science.gov (United States)

    Buhule, O D; Wahed, A S; Youk, A O

    2017-08-22

    Modeling of correlated biomarkers jointly has been shown to improve the efficiency of parameter estimates, leading to better clinical decisions. In this paper, we employ a joint modeling approach to a unique diabetes dataset, where blood glucose (continuous) and urine glucose (ordinal) measures of disease severity for diabetes are known to be correlated. The postulated joint model assumes that the outcomes are from distributions that are in the exponential family and hence modeled as multivariate generalized linear mixed effects model associated through correlated and/or shared random effects. The Markov chain Monte Carlo Bayesian approach is used to approximate posterior distribution and draw inference on the parameters. This proposed methodology provides a flexible framework to account for the hierarchical structure of the highly unbalanced data as well as the association between the 2 outcomes. The results indicate improved efficiency of parameter estimates when blood glucose and urine glucose are modeled jointly. Moreover, the simulation studies show that estimates obtained from the joint model are consistently less biased and more efficient than those in the separate models. Copyright © 2017 John Wiley & Sons, Ltd.

  18. Use of rapid HIV assays as supplemental tests in specimens with repeatedly reactive screening immunoassay results not confirmed by HIV-1 Western blot.

    Science.gov (United States)

    Wesolowski, Laura G; Delaney, Kevin P; Meyer, William A; Blatt, Amy J; Bennett, Berry; Chavez, Pollyanna; Granade, Timothy C; Owen, Michele

    2013-09-01

    An alternate HIV testing algorithm has been proposed which includes a fourth-generation immunoassay followed by an HIV-1/HIV-2 antibody differentiation supplemental test for reactive specimens and a nucleic acid test (NAT) for specimens with discordant results. To evaluate the performance of five rapid tests (Alere Clearview, Bio-Rad Multispot, OraSure OraQuick, MedMira Reveal, and Trinity Biotech Unigold) as the supplemental antibody assay in the algorithm. A total of 3273 serum and plasma specimens that were third-generation immunoassay repeatedly reactive and Western blot (WB) negative or indeterminate were tested with rapid tests and NAT. Specimens were classified by NAT: (1) HIV-1 infected (NAT-reactive; n=184, 5.6%), (2) HIV-status unknown (NAT nonreactive; n=3078, 94.2%) or by Multispot, (3) HIV-2 positive (n=5), and (4) HIV-1 and HIV-2 positive (n=6). Excluding HIV-2 positive specimens, we calculated the proportion of reactive rapid tests among specimens with reactive and nonreactive NAT. The proportion of infected specimens with reactive rapid test results and negative or indeterminate WB ranged from 30.4% (56) to 47.8% (88) depending on the rapid test. From 1% to 2% of NAT-negative specimens had reactive rapid test results. In these diagnostically challenging specimens, all rapid tests identified infections that were missed by the Western blot, but only Multispot could differentiate HIV-1 from HIV-2. Regardless of which rapid test is used as a supplemental test in the alternative algorithm, false-positive algorithm results (i.e., reactive screening and rapid test in uninfected person) may occur, which will need to be resolved during the baseline medical evaluation. Published by Elsevier B.V.

  19. The reliability of repeated TMS measures in older adults and in patients with subacute and chronic stroke

    Directory of Open Access Journals (Sweden)

    Heidi M. Schambra

    2015-09-01

    Full Text Available The reliability of transcranial magnetic stimulation (TMS measures in healthy older adults and stroke patients has been insufficiently characterized. We determined whether common TMS measures could reliably evaluate change in individuals and in groups using the smallest detectable change (SDC, or could tell subjects apart using the intraclass correlation coefficient (ICC. We used a single-rater test-retest design in older healthy, subacute stroke, and chronic stroke subjects. At twice daily sessions on two consecutive days, we recorded resting motor threshold, test stimulus intensity, recruitment curves, short-interval intracortical inhibition and facilitation, and long-interval intracortical inhibition. Using variances estimated from a random effects model, we calculated the SDC and ICC for each TMS measure. For all TMS measures in all groups, SDCs for single subjects were large; only with modest group sizes did the SDCs become low. Thus, while these TMS measures cannot be reliably used as a biomarker to detect individual change, they can reliably detect change exceeding measurement noise in moderate-sized groups. For several of the TMS measures, ICCs were universally high, suggesting that they can reliably discriminate between subjects. Though most TMS measures have sufficient reliability in particular contexts, work establishing their validity, responsiveness, and clinical relevance is still needed.

  20. Comparison of intraclass correlation coefficient estimates and standard errors between using cross-sectional and repeated measurement data: the Safety Check cluster randomized trial.

    Science.gov (United States)

    Ip, Edward H; Wasserman, Richard; Barkin, Shari

    2011-03-01

    Designing cluster randomized trials in clinical studies often requires accurate estimates of intraclass correlation, which quantifies the strength of correlation between units, such as participants, within a cluster, such as a practice. Published ICC estimates, even when available, often suffer from the problem of wide confidence intervals. Using data from a national, randomized, controlled study concerning violence prevention for children--the Safety Check--we compare the ICC values derived from two approaches only baseline data and using both baseline and follow-up data. Using a variance component decomposition approach, the latter method allows flexibility in handling complex data sets. For example, it allows for shifts in the outcome variable over time and for an unbalanced cluster design. Furthermore, we evaluate the large-sample formula for ICC estimates and standard errors using the bootstrap method. Our findings suggest that ICC estimates range from 0.012 to 0.11 for providers within practice and range from 0.018 to 0.11 for families within provider. The estimates derived from the baseline-only and repeated-measurements approaches agree quite well except in cases in which variation over repeated measurements is large. The reductions in the widths of ICC confidence limits from using repeated measurement over baseline only are, respectively, 62% and 42% at the practice and provider levels. The contribution of this paper therefore includes two elements, which are a methodology for improving the accuracy of ICC, and the reporting of such quantities for pediatric and other researchers who are interested in designing clustered randomized trials similar to the current study.

  1. Which are the most useful scales for predicting repeat self-harm? A systematic review evaluating risk scales using measures of diagnostic accuracy

    Science.gov (United States)

    Quinlivan, L; Cooper, J; Davies, L; Hawton, K; Gunnell, D; Kapur, N

    2016-01-01

    Objectives The aims of this review were to calculate the diagnostic accuracy statistics of risk scales following self-harm and consider which might be the most useful scales in clinical practice. Design Systematic review. Methods We based our search terms on those used in the systematic reviews carried out for the National Institute for Health and Care Excellence self-harm guidelines (2012) and evidence update (2013), and updated the searches through to February 2015 (CINAHL, EMBASE, MEDLINE, and PsychINFO). Methodological quality was assessed and three reviewers extracted data independently. We limited our analysis to cohort studies in adults using the outcome of repeat self-harm or attempted suicide. We calculated diagnostic accuracy statistics including measures of global accuracy. Statistical pooling was not possible due to heterogeneity. Results The eight papers included in the final analysis varied widely according to methodological quality and the content of scales employed. Overall, sensitivity of scales ranged from 6% (95% CI 5% to 6%) to 97% (CI 95% 94% to 98%). The positive predictive value (PPV) ranged from 5% (95% CI 3% to 9%) to 84% (95% CI 80% to 87%). The diagnostic OR ranged from 1.01 (95% CI 0.434 to 2.5) to 16.3 (95%CI 12.5 to 21.4). Scales with high sensitivity tended to have low PPVs. Conclusions It is difficult to be certain which, if any, are the most useful scales for self-harm risk assessment. No scales perform sufficiently well so as to be recommended for routine clinical use. Further robust prospective studies are warranted to evaluate risk scales following an episode of self-harm. Diagnostic accuracy statistics should be considered in relation to the specific service needs, and scales should only be used as an adjunct to assessment. PMID:26873046

  2. Urban traffic noise assessment by combining measurement and model results

    NARCIS (Netherlands)

    Eerden, F.J.M. van der; Graafland, F.; Wessels, P.W.; Basten, T.G.H.

    2013-01-01

    A model based monitoring system is applied on a local scale in an urban area to obtain a better understanding of the traffic noise situation. The system consists of a scalable sensor network and an engineering model. A better understanding is needed to take appropriate and cost efficient measures,

  3. 26 CFR 801.6 - Business results measures.

    Science.gov (United States)

    2010-04-01

    ... audit. Records of tax enforcement results do not include tax enforcement results of individual cases... IRS personnel provided accurate tax law and account information. (3) Other work units. The quality... data that does not contain information regarding the tax enforcement result reached in any case...

  4. The Effects of Repeat Testing, Malingering, and Traumatic Brain Injury on Computerized Measures of Visuospatial Memory Span.

    Science.gov (United States)

    Woods, David L; Wyma, John M; Herron, Timothy J; Yund, E W

    2015-01-01

    Spatial span tests (SSTs) such as the Corsi Block Test (CBT) and the SST of the Wechsler Memory Scale are widely used to assess deficits in spatial working memory. We conducted three experiments to evaluate the test-retest reliability and clinical sensitivity of a new computerized spatial span test (C-SST) that incorporates psychophysical methods to improve the precision of spatial span measurement. In Experiment 1, we analyzed C-SST test-retest reliability in 49 participants who underwent three test sessions at weekly intervals. Intraclass correlation coefficients (ICC) were higher for a psychophysically derived mean span (MnS) metric (0.83) than for the maximal span and total correct metrics used in traditional spatial-span tests. Response times (ReTs) also showed high ICCs (0.93) that correlated negatively with MnS scores and correlated positively with response-time latencies from other tests of processing speed. Learning effects were insignificant. Experiment 2 examined the performance of Experiment 1 participants when instructed to feign symptoms of traumatic brain injury (TBI): 57% showed abnormal MnS z-scores. A MnS z-score cutoff of 3.0 correctly classified 36% of simulated malingerers and 91% of the subgroup of 11 control participants with abnormal spans. Malingerers also made more substitution errors than control participants with abnormal spans (sensitivity = 43%, specificity = 91%). In addition, malingerers showed no evidence of ReT slowing, in contrast to significant abnormalities seen on other malingered tests of processing speed. As a result, differences between ReT z-scores and z-scores on other processing speed tests showed very high sensitivity and specificity in distinguishing malingering and control participants with either normal or abnormal spans. Experiment 3 examined C-SST performance in a group of patients with predominantly mild TBI: neither MnS nor ReT z-scores showed significant group-level abnormalities. The C-SST improves the

  5. The near-infrared spectroscopy-derived deoxygenated haemoglobin breaking-point is a repeatable measure that demarcates exercise intensity domains.

    Science.gov (United States)

    Iannetta, Danilo; Qahtani, Ahmad; Mattioni Maturana, Felipe; Murias, Juan Manuel

    2017-09-01

    A breaking-point in the near-infrared spectroscopy (NIRS)-derived deoxygenated haemoglobin ([HHb]) profile towards the end of a ramp incremental (RI) cycling test has been associated to the respiratory compensation point (RCP). Despite the physiological value of this measure, its repeatability remains unknown. The aim was to examine the repeatability of the [HHb] breaking-point ([HHb]BP) and its association to RCP during a RI cycling test. A repeated measures design was performed on 11 males (30.5±8.4 year; 76.5±8.4kg) and 4 females (30.5±5.9 year; 61.9±4.4 Kg). Gas exchange and NIRS [HHb] data were collected during RI tests performed on two different days separated by 48h. The [HHb]BP and the RCP were determined and compared for each trial. The [HHb]BP and the respiratory compensation point (RCP) occurred at the same VO2 in test 1 and test 2 ([HHb]BP: 3.49±0.52Lmin(-1) test 1; 3.48±0.45Lmin(-1) test 2; RCP: 3.38±0.40Lmin(-1) test 1; 3.38±0.44Lmin(-1) test 2) (P>0.05). The VO2 associated with the [HHb]BP and the VO2 at RCP were not significantly different from each other either in test 1 as well as in test 2 (P>0.05). Neither test 1 nor test 2 showed significant mean average error between the VO2 at the [HHb]BP and RCP using Bland & Altman plots. The [HHb]BP is a repeatable measure that consistently occurs towards the end of a RI test. The association between the [HHb]BP and the RCP reinforces the idea that these parameters may share similar mechanistic basis. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  6. Vehicular-to-vehicular channel characterization and measurement results

    OpenAIRE

    CAMPUZANO CANDEL, ANDRÉS JOSÉ; FERNÁNDEZ GONZÁLEZ, HERMAN ANTONIO; BALAGUER ANDRÉS, DAVID; Vila Jiménez, Antonio; Bernardo Clemente, Bernardo; Rodrigo Peñarrocha, Vicent Miquel; Reig, Juan; Valero-Nogueira, Alejandro; Rubio Arjona, Lorenzo

    2012-01-01

    Vehicular-to-Vehicular (V2V) communications are receiving considerable attention due to the introduction of the intelligent transportation system (ITS) concept. To design, evaluate and optimize ITS applications oriented to vehicular safety based on wireless systems, the knowledge of the propagation channel is vital, in particular the path loss. From a narrowband V2V channel measurements campaign carried out in a suburban area of the city of Valencia (Spain), this paper...

  7. The healthy building intervention study: Objectives, methods and results of selected environmental measurements

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, W.J.; Faulkner, D.; Sullivan, D. [and others

    1998-02-17

    To test proposed methods for reducing SBS symptoms and to learn about the causes of these symptoms, a double-blind controlled intervention study was designed and implemented. This study utilized two different interventions designed to reduce occupants` exposures to airborne particles: (1) high efficiency filters in the building`s HVAC systems; and (2) thorough cleaning of carpeted floors and fabric-covered chairs with an unusually powerful vacuum cleaner. The study population was the workers on the second and fourth floors of a large office building with mechanical ventilation, air conditioning, and sealed windows. Interventions were implemented on one floor while the occupants on the other floor served as a control group. For the enhanced-filtration intervention, a multiple crossover design was used (a crossover is a repeat of the experiment with the former experimental group as the control group and vice versa). Demographic and health symptom data were collected via an initial questionnaire on the first study week and health symptom data were obtained each week, for eight additional weeks, via weekly questionnaires. A large number of indoor environmental parameters were measured during the study including air temperatures and humidities, carbon dioxide concentrations, particle concentrations, concentrations of several airborne bioaerosols, and concentrations of several microbiologic compounds within the dust sampled from floors and chairs. This report describes the study methods and summarizes the results of selected environmental measurements.

  8. Standardization of reflectance measurements in dispersed organic matter: results of an exercise to improve interlaboratory agreement

    Science.gov (United States)

    Hackley, Paul C.; Araujo, Carla Viviane; Borrego, Angeles G.; Bouzinos, Antonis; Cardott, Brian; Cook, Alan C.; Eble, Cortland; Flores, Deolinda; Gentzis, Thomas; Gonçalves, Paula Alexandra; Filho, João Graciano Mendonça; Hámor-Vidó, Mária; Jelonek, Iwona; Kommeren, Kees; Knowles, Wayne; Kus, Jolanta; Mastalerz, Maria; Menezes, Taíssa Rêgo; Newman, Jane; Pawlewicz, Mark; Pickel, Walter; Potter, Judith; Ranasinghe, Paddy; Read, Harold; Reyes, Julito; Rodriguez, Genaro De La Rosa; de Souza, Igor Viegas Alves Fernandes; Suarez-Ruiz, Isabel; Sýkorová, Ivana; Valentine, Brett J.

    2015-01-01

    Vitrinite reflectance generally is considered the most robust thermal maturity parameter available for application to hydrocarbon exploration and petroleum system evaluation. However, until 2011 there was no standardized methodology available to provide guidelines for vitrinite reflectance measurements in shale. Efforts to correct this deficiency resulted in publication of ASTM D7708: Standard test method for microscopical determination of the reflectance of vitrinite dispersed in sedimentary rocks. In 2012-2013, an interlaboratory exercise was conducted to establish precision limits for the D7708 measurement technique. Six samples, representing a wide variety of shale, were tested in duplicate by 28 analysts in 22 laboratories from 14 countries. Samples ranged from immature to overmature (0.31-1.53% Ro), from organic-lean to organic-rich (1-22 wt.% total organic carbon), and contained Type I (lacustrine), Type II (marine), and Type III (terrestrial) kerogens. Repeatability limits (maximum difference between valid repetitive results from same operator, same conditions) ranged from 0.03-0.11% absolute reflectance, whereas reproducibility limits (maximum difference between valid results obtained on same test material by different operators, different laboratories) ranged from 0.12-0.54% absolute reflectance. Repeatability and reproducibility limits degraded consistently with increasing maturity and decreasing organic content. However, samples with terrestrial kerogens (Type III) fell off this trend, showing improved levels of reproducibility due to higher vitrinite content and improved ease of identification. Operators did not consistently meet the reporting requirements of the test method, indicating that a common reporting template is required to improve data quality. The most difficult problem encountered was the petrographic distinction of solid bitumens and low-reflecting inert macerals from vitrinite when vitrinite occurred with reflectance ranges overlapping

  9. Variation in repeated mouth-opening measurements in head and neck cancer patients with and without trismus

    NARCIS (Netherlands)

    Jager-Wittenaar, H.; Dijkstra, P. U.; Vissink, A.; van Oort, R. P.; Roodenburg, J. L. N.

    2009-01-01

    Trismus after head and neck cancer treatment may severely limit mandibular functioning. Interventions aimed at reducing trismus can only be evaluated when the amount of variation associated with these measurements is known. The aim of this Study was to analyse the variation in mouth-opening measurem

  10. Repeated measurements of mite and pet allergen levels in house dust over a time period of 8 years

    NARCIS (Netherlands)

    Antens, C. J. M.; Oldenwening, M.; Wolse, A.; Gehring, U.; Smit, H. A.; Aalberse, R. C.; Kerkhof, M.; Gerritsen, J.; de Jongste, J. C.; Brunekreef, B.

    2006-01-01

    Background Studies of the association between indoor allergen exposure and the development of allergic diseases have often measured allergen exposure at one point in time. Objective We investigated the variability of house dust mite (Der p 1, Der f 1) and cat (Fel d 1) allergen in Dutch homes over a

  11. Variation in repeated mouth-opening measurements in head and neck cancer patients with and without trismus

    NARCIS (Netherlands)

    Jager-Wittenaar, H.; Dijkstra, P. U.; Vissink, A.; van Oort, R. P.; Roodenburg, J. L. N.

    2009-01-01

    Trismus after head and neck cancer treatment may severely limit mandibular functioning. Interventions aimed at reducing trismus can only be evaluated when the amount of variation associated with these measurements is known. The aim of this Study was to analyse the variation in mouth-opening measurem

  12. Variation in repeated mouth-opening measurements in head and neck cancer patients with and without trismus

    NARCIS (Netherlands)

    Jager-Wittenaar, H.; Dijkstra, P. U.; Vissink, A.; van Oort, R. P.; Roodenburg, J. L. N.

    Trismus after head and neck cancer treatment may severely limit mandibular functioning. Interventions aimed at reducing trismus can only be evaluated when the amount of variation associated with these measurements is known. The aim of this Study was to analyse the variation in mouth-opening

  13. Repeated measurements of mite and pet allergen levels in house dust over a time period of 8 years

    NARCIS (Netherlands)

    Antens, C. J. M.; Oldenwening, M.; Wolse, A.; Gehring, U.; Smit, H. A.; Aalberse, R. C.; Kerkhof, M.; Gerritsen, J.; de Jongste, J. C.; Brunekreef, B.

    2006-01-01

    Background Studies of the association between indoor allergen exposure and the development of allergic diseases have often measured allergen exposure at one point in time. Objective We investigated the variability of house dust mite (Der p 1, Der f 1) and cat (Fel d 1) allergen in Dutch homes over a

  14. Environmentally friendly pavements: Results from noise measurements 2005-2008

    OpenAIRE

    Berge, Truls Svenn; Haukland, Frode; Ustad, Asbjørn

    2009-01-01

    CPX-measurements (tyre A) have been performed on a wide range of ordinary dense Norwegian road pavements and special test pavements, as part of the R&D project “Environmental friendly pavements” initiated by the Norwegian Public Roads Administration. The following conclusions can be made from the investigation:- New dense asphalt concrete pavements can give a tyre/road noise level (CPX) of 4-8 dB(A) lower noise level, compared to a chosen reference level for a pavement of type AC 0/11 and SMA...

  15. First measurements results of the LHC longitudinal density monitor

    CERN Document Server

    Jeff , A; Bravin, E; Boccardi, A; Bozyigit, S; Lefevre, T; Rabiller, A; Roncarolo, F; Welsch, C P; Fisher, A S

    2011-01-01

    Knowledge of the longitudinal distribution of particles is important for various aspects of accelerator operation, for example to check the injection quality and to characterize the development of ghost bunches before and during the physics periods. A new detector, the LHC Longitudinal Density Monitor (LDM) is a single-photon counting system measuring synchrotron light by means of an avalanche photodiode detector. The unprecedented energies reached in the LHC allow synchrotron light diagnostics to be used with both protons and heavy ions. The LDM is able to longitudinally profile the whole ring with a resolution close to the target of 50 ps. On-line correction for the effects of the detector deadtime, pile-up and afterpulsing allow a dynamic range of 105 to be achieved. The LDM operated during the 2010 lead ion run and during 2011 with protons. Measurements from both runs are presented in this contribution along with an analysis of the LDM performance and an outlook for future upgrades.

  16. R&D and Productivity: Measurement Issues and Econometric Results.

    Science.gov (United States)

    Griliches, Zvi

    1987-01-01

    Discusses the relationship and contributions of research and development (R&D) to productivity growth in the United States. Focuses on the impacts of industrial R&D and presents study results on trends in productivity. (ML)

  17. A technique for conditioning and calibrating force-sensing resistors for repeatable and reliable measurement of compressive force.

    Science.gov (United States)

    Hall, Rick S; Desmoulin, Geoffrey T; Milner, Theodore E

    2008-12-01

    Miniature sensors that could measure forces applied by the fingers and hand without interfering with manual dexterity or range of motion would have considerable practical value in ergonomics and rehabilitation. In this study, techniques have been developed to use inexpensive pressure-sensing resistors (FSRs) to accurately measure compression force. The FSRs are converted from pressure-sensing to force-sensing devices. The effects of nonlinear response properties and dependence on loading history are compensated by signal conditioning and calibration. A fourth-order polynomial relating the applied force to the current voltage output and a linearly weighted sum of prior outputs corrects for sensor hysteresis and drift. It was found that prolonged (>20h) shear force loading caused sensor gain to change by approximately 100%. Shear loading also had the effect of eliminating shear force effects on sensor output, albeit only in the direction of shear loading. By applying prolonged shear loading in two orthogonal directions, the sensors were converted into pure compression sensors. Such preloading of the sensor is, therefore, required prior to calibration. The error in compression force after prolonged shear loading and calibration was consistently industrial design applications where measurements of finger and hand force are needed.

  18. Repeated measures of body mass index and C-reactive protein in relation to all-cause mortality and cardiovascular disease

    DEFF Research Database (Denmark)

    O'Doherty, Mark G; Jørgensen, Torben; Borglykke, Anders

    2014-01-01

    Obesity has been linked with elevated levels of C-reactive protein (CRP), and both have been associated with increased risk of mortality and cardiovascular disease (CVD). Previous studies have used a single 'baseline' measurement and such analyses cannot account for possible changes in these which...... body mass index (BMI) and CRP with all-cause mortality and CVD. Being overweight (≥25-obese (≥30-....79-0.94) and 0.80 (0.72-0.89). A similar relationship was found, but only for overweight in Glostrup, HR (95 % CI) 0.88 (0.76-1.02); and moderately obese in Tromsø, HR (95 % CI) 0.79 (0.62-1.01). Associations were not evident between repeated measures of BMI and CVD. Conversely, increasing CRP concentrations...

  19. Effect of Repeated Simulations by Standardized Patients on Intercase Reliability.

    Science.gov (United States)

    Colliver, Jerry A.; And Others

    1991-01-01

    A study using five Southern Illinois University senior medical school classes (n=350 students) investigated whether having a standardized patient simulate a case repeatedly in postclerkship medical student evaluation affects the measure's reliability. Results suggest that repeated simulation had little or no effect on intercase reliability of…

  20. Particle Morphology and Size Results from the Smoke Aerosol Measurement Experiment-2

    Science.gov (United States)

    Urban, David L.; Ruff, Gary A.; Greenberg, Paul S.; Fischer, David; Meyer, Marit; Mulholland, George; Yuan, Zeng-Guang; Bryg, Victoria; Cleary, Thomas; Yang, Jiann

    2012-01-01

    Results are presented from the Reflight of the Smoke Aerosol Measurement Experiment (SAME-2) which was conducted during Expedition 24 (July-September 2010). The reflight experiment built upon the results of the original flight during Expedition 15 by adding diagnostic measurements and expanding the test matrix. Five different materials representative of those found in spacecraft (Teflon, Kapton, cotton, silicone rubber and Pyrell) were heated to temperatures below the ignition point with conditions controlled to provide repeatable sample surface temperatures and air flow. The air flow past the sample during the heating period ranged from quiescent to 8 cm/s. The smoke was initially collected in an aging chamber to simulate the transport time from the smoke source to the detector. This effective transport time was varied by holding the smoke in the aging chamber for times ranging from 11 to 1800 s. Smoke particle samples were collected on Transmission Electron Microscope (TEM) grids for post-flight analysis. The TEM grids were analyzed to observe the particle morphology and size parameters. The diagnostics included a prototype two-moment smoke detector and three different measures of moments of the particle size distribution. These moment diagnostics were used to determine the particle number concentration (zeroth moment), the diameter concentration (first moment), and the mass concentration (third moment). These statistics were combined to determine the diameter of average mass and the count mean diameter and, by assuming a log-normal distribution, the geometric mean diameter and the geometric standard deviations can also be calculated. Overall the majority of the average smoke particle sizes were found to be in the 200 nm to 400 nm range with the quiescent cases producing some cases with substantially larger particles.

  1. Duct Leakage Repeatability Testing

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sherman, Max [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-01-01

    Duct leakage often needs to be measured to demonstrate compliance with requirements or to determine energy or Indoor Air Quality (IAQ) impacts. Testing is often done using standards such as ASTM E1554 (ASTM 2013) or California Title 24 (California Energy Commission 2013 & 2013b), but there are several choices of methods available within the accepted standards. Determining which method to use or not use requires an evaluation of those methods in the context of the particular needs. Three factors that are important considerations are the cost of the measurement, the accuracy of the measurement and the repeatability of the measurement. The purpose of this report is to evaluate the repeatability of the three most significant measurement techniques using data from the literature and recently obtained field data. We will also briefly discuss the first two factors. The main question to be answered by this study is to determine if differences in the repeatability of these tests methods is sufficient to indicate that any of these methods is so poor that it should be excluded from consideration as an allowed procedure in codes and standards.

  2. The STAR W Program : New Results and Future Measurements

    CERN Document Server

    Seele, Joseph

    2010-01-01

    The production of $W^\\pm$ bosons in longitudinally polarized p+p collisions at RHIC provides a new means of studying the spin-flavour asymmetries of the proton sea quark spin distributions. Details of the W$^\\pm$ event selection through the $e^\\pm$ decay channel at mid-rapidity are presented, along with preliminary results for the production cross section and parity-violating single-spin asymmetry, $A_L$, from the STAR Collaboration's 2009 data set at $\\sqrt{s} = 500$ GeV. Lastly, the expected sensitivities for future running are discussed.

  3. Repeated-measure validation of craniofacial metrics from three-dimensional surface scans: application to medical genetics

    Science.gov (United States)

    Lauer, Eric A.; Corner, Brian D.; Li, Peng; Beecher, Robert M.; Deutsch, Curtis

    2002-03-01

    Traditionally, medical geneticists have employed visual inspection (anthroposcopy) to clinically evaluate dysmorphology. In the last 20 years, there has been an increasing trend towards quantitative assessment to render diagnosis of anomalies more objective and reliable. These methods have focused on direct anthropometry, using a combination of classical physical anthropology tools and new instruments tailor-made to describe craniofacial morphometry. These methods are painstaking and require that the patient remain still for extended periods of time. Most recently, semiautomated techniques (e.g., structured light scanning) have been developed to capture the geometry of the face in a matter of seconds. In this paper, we establish that direct anthropometry and structured light scanning yield reliable measurements, with remarkably high levels of inter-rater and intra-rater reliability, as well as validity (contrasting the two methods).

  4. Measured Zero Net Energy Performance: Results, Lessons, and Surprises

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Carrie; LaRue, Anna; Pigman, Margaret; Roberts, Jon; Kaneda, David; Connelly, Dylan; Elliott, John; Pless, Shanti; Pande, Abhijeet; Dean, Edward; Anbarlilar, Can

    2016-08-26

    As more and more zero net energy (ZNE) buildings are built and monitored, we can learn from both careful case studies of individual projects as well as a broader perspective of trends over time. In a forum sponsored by Pacific Gas and Electric Company (PG&E), eight expert speakers discussed: results and lessons from monitoring occupied ZNE buildings; best practices for setting performance targets and getting actionable performance information, and; things that have surprised them about monitored ZNE buildings. This paper distills the content of the forum by laying out the most common hurdles that are encountered in setting up monitoring projects, frequent performance issues that the monitoring uncovers, and lessons learned that can be applied to future projects.

  5. Fine-resolution repeat topographic surveying of dryland landscapes using UAS-based structure-from-motion photogrammetry: Assessing accuracy and precision against traditional ground-based erosion measurements

    Science.gov (United States)

    Gillian, Jeffrey K.; Karl, Jason W.; Elaksher, Ahmed; Duniway, Michael C.

    2017-01-01

    Structure-from-motion (SfM) photogrammetry from unmanned aerial system (UAS) imagery is an emerging tool for repeat topographic surveying of dryland erosion. These methods are particularly appealing due to the ability to cover large landscapes compared to field methods and at reduced costs and finer spatial resolution compared to airborne laser scanning. Accuracy and precision of high-resolution digital terrain models (DTMs) derived from UAS imagery have been explored in many studies, typically by comparing image coordinates to surveyed check points or LiDAR datasets. In addition to traditional check points, this study compared 5 cm resolution DTMs derived from fixed-wing UAS imagery with a traditional ground-based method of measuring soil surface change called erosion bridges. We assessed accuracy by comparing the elevation values between DTMs and erosion bridges along thirty topographic transects each 6.1 m long. Comparisons occurred at two points in time (June 2014, February 2015) which enabled us to assess vertical accuracy with 3314 data points and vertical precision (i.e., repeatability) with 1657 data points. We found strong vertical agreement (accuracy) between the methods (RMSE 2.9 and 3.2 cm in June 2014 and February 2015, respectively) and high vertical precision for the DTMs (RMSE 2.8 cm). Our results from comparing SfM-generated DTMs to check points, and strong agreement with erosion bridge measurements suggests repeat UAS imagery and SfM processing could replace erosion bridges for a more synoptic landscape assessment of shifting soil surfaces for some studies. However, while collecting the UAS imagery and generating the SfM DTMs for this study was faster than collecting erosion bridge measurements, technical challenges related to the need for ground control networks and image processing requirements must be addressed before this technique could be applied effectively to large landscapes.

  6. Feedback from an image of finger and an actual finger produce similar prismatic after-effect: a repeated measures study

    DEFF Research Database (Denmark)

    Wilms, Inge Linda; Assentoft, Emilie

    2014-01-01

    by seeing their fingertip. In the second condition subjects saw an image of a fingertip. The results indicate that the two conditions are significantly different. The study is an important step in understanding what actually makes a difference in training when trying to convert paper-and-pencil training...... if it is the format rather than the indirectness of the feedback creating this difference. 27 healthy subjects were subjected to a single session of Prism Adaptation Training under two different feedback conditions. In the first feedback condition, subjects were exposed to visual feedback on pointing precision...

  7. Two to five repeated measurements per patient reduced the required sample size considerably in a randomized clinical trial for patients with inflammatory rheumatic diseases

    Directory of Open Access Journals (Sweden)

    Smedslund Geir

    2013-02-01

    Full Text Available Abstract Background Patient reported outcomes are accepted as important outcome measures in rheumatology. The fluctuating symptoms in patients with rheumatic diseases have serious implications for sample size in clinical trials. We estimated the effects of measuring the outcome 1-5 times on the sample size required in a two-armed trial. Findings In a randomized controlled trial that evaluated the effects of a mindfulness-based group intervention for patients with inflammatory arthritis (n=71, the outcome variables Numerical Rating Scales (NRS (pain, fatigue, disease activity, self-care ability, and emotional wellbeing and General Health Questionnaire (GHQ-20 were measured five times before and after the intervention. For each variable we calculated the necessary sample sizes for obtaining 80% power (α=.05 for one up to five measurements. Two, three, and four measures reduced the required sample sizes by 15%, 21%, and 24%, respectively. With three (and five measures, the required sample size per group was reduced from 56 to 39 (32 for the GHQ-20, from 71 to 60 (55 for pain, 96 to 71 (73 for fatigue, 57 to 51 (48 for disease activity, 59 to 44 (45 for self-care, and 47 to 37 (33 for emotional wellbeing. Conclusions Measuring the outcomes five times rather than once reduced the necessary sample size by an average of 27%. When planning a study, researchers should carefully compare the advantages and disadvantages of increasing sample size versus employing three to five repeated measurements in order to obtain the required statistical power.

  8. Mature clustered, regularly interspaced, short palindromic repeats RNA (crRNA) length is measured by a ruler mechanism anchored at the precursor processing site.

    Science.gov (United States)

    Hatoum-Aslan, Asma; Maniv, Inbal; Marraffini, Luciano A

    2011-12-27

    Precise RNA processing is fundamental to all small RNA-mediated interference pathways. In prokaryotes, clustered, regularly interspaced, short palindromic repeats (CRISPR) loci encode small CRISPR RNAs (crRNAs) that protect against invasive genetic elements by antisense targeting. CRISPR loci are transcribed as a long precursor that is cleaved within repeat sequences by CRISPR-associated (Cas) proteins. In many organisms, this primary processing generates crRNA intermediates that are subject to additional nucleolytic trimming to render mature crRNAs of specific lengths. The molecular mechanisms underlying this maturation event remain poorly understood. Here, we defined the genetic requirements for crRNA primary processing and maturation in Staphylococcus epidermidis. We show that changes in the position of the primary processing site result in extended or diminished maturation to generate mature crRNAs of constant length. These results indicate that crRNA maturation occurs by a ruler mechanism anchored at the primary processing site. We also show that maturation is mediated by specific cas genes distinct from those genes involved in primary processing, showing that this event is directed by CRISPR/Cas loci.

  9. NEIGHBOURHOOD POVERTY, PERCEIVED DISCRIMINATION AND CENTRAL ADIPOSITY IN THE USA: INDEPENDENT ASSOCIATIONS IN A REPEATED MEASURES ANALYSIS.

    Science.gov (United States)

    Kwarteng, Jamila L; Schulz, Amy J; Mentz, Graciela B; Israel, Barbara A; Shanks, Trina R; Perkins, Denise White

    2016-11-01

    This study examines the independent effects of neighbourhood context (i.e. neighbourhood poverty) and exposure to perceived discrimination in shaping risk of obesity over time. Weighted three-level hierarchical linear regression models for a continuous outcome were used to assess the independent effects of neighbourhood poverty and perceived discrimination on obesity over time in a sample of 157 non-Hispanic Black, non-Hispanic White and Hispanic adults in Detroit, USA, in 2002/2003 and 2007/2008. Independent associations were found between neighbourhood poverty and perceived discrimination with central adiposity over time. Residents of neighbourhoods with high concentrations of poverty were more likely to show increases in central adiposity compared with those in neighbourhoods with lower concentrations of poverty. In models adjusted for BMI, neighbourhood poverty at baseline was associated with a greater change in central adiposity among participants who lived in neighbourhoods in the second (B=3.79, p=0.025) and third (B=3.73, p=0.024) poverty quartiles, compared with those in the lowest poverty neighbourhoods. The results from models that included both neighbourhood poverty and perceived discrimination showed that both were associated with increased risk of increased central adiposity over time. Residents of neighbourhoods in the second (B=9.58, p<0.001), third (B=8.25, p=0.004) and fourth (B=7.66, p=0.030) quartiles of poverty were more likely to show greater increases in central adiposity over time, compared with those in the lowest poverty quartile, with mean discrimination at baseline independently and positively associated with increases in central adiposity over time (B=2.36, p=0.020). The results suggest that neighbourhood poverty and perceived discrimination are independently associated with a heightened risk of increase in central adiposity over time. Efforts to address persistent disparities in central adiposity in the USA should include strategies to

  10. Teaching renewable energy using online PBL in investigating its effect on behaviour towards energy conservation among Malaysian students: ANOVA repeated measures approach

    Science.gov (United States)

    Nordin, Norfarah; Samsudin, Mohd Ali; Hadi Harun, Abdul

    2017-01-01

    This research aimed to investigate whether online problem based learning (PBL) approach to teach renewable energy topic improves students’ behaviour towards energy conservation. A renewable energy online problem based learning (REePBaL) instruction package was developed based on the theory of constructivism and adaptation of the online learning model. This study employed a single group quasi-experimental design to ascertain the changed in students’ behaviour towards energy conservation after underwent the intervention. The study involved 48 secondary school students in a Malaysian public school. ANOVA Repeated Measure technique was employed in order to compare scores of students’ behaviour towards energy conservation before and after the intervention. Based on the finding, students’ behaviour towards energy conservation improved after the intervention.

  11. The effect of technical replicate (repeats) on Nix Pro Color Sensor™ measurement precision for meat: A case-study on aged beef colour stability.

    Science.gov (United States)

    Holman, Benjamin W B; Collins, Damian; Kilgannon, Ashleigh K; Hopkins, David L

    2017-09-04

    The Nix Pro Colour Sensor™ (NIX) can be potentially used to measure meat colour, but procedural guidelines that assure measurement reproducibility and repeatability (precision) must first be established. Technical replicate number (r) will minimise response variation, measureable as standard error of predicted mean (SEM), and contribute to improved precision. Consequently, we aimed to explore the effects of r on NIX precision when measuring aged beef colour (colorimetrics; L*, a*, b*, hue and chroma values). Each colorimetric SEM declined with increasing r to indicate improved precision and followed a diminishing rate of improvement that allowed us to recommend r=7 for meat colour studies using the NIX. This definition was based on practical limitations and a* variability, as additional r would be required if other colorimetrics or advanced levels of precision are necessary. Beef ageing and display period, holding temperature, loin and sampled portion were also found to contribute to colorimetric variation, but were incorporated within our definition of r. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  12. Getting Results in Housing: A Framework for Monitoring Results in Housing Projects: Using Measurable Indicators

    OpenAIRE

    Shlomo Angel; Michael Jacobs

    2006-01-01

    The aim of this paper is to help project teams develop results indicators for housing projects. These indicators are intended, primarily, as an instrument for managing projects and should help staff in the country offices, in headquarters and in executing agencies to identify the components of a project that are working as intended, and the ones that may need attention to keep the project on track. Additionally, the indicators can provide a foundation for project evaluations, at the mid-term ...

  13. Changes in surgical team performance and safety climate attitudes following expansion of perioperative services: a repeated-measures study.

    Science.gov (United States)

    Gillespie, Brigid M; Harbeck, Emma; Kang, Evelyn; Steel, Catherine; Fairweather, Nicole; Chaboyer, Wendy

    2017-08-10

    Objective The aim of the present study was to describe process changes in surgical team performance and team members' attitudes to safety culture following hospital relocation and expansion of perioperative services.Methods The study was a naturalistic study using structured observations and surveys to assess non-technical skills (NTS; i.e. communication, teamwork, situational awareness, decision making and leadership) in surgery. This interrupted time series design used mixed-linear regression models to examine the effect of phase (before and after hospital relocation) on surgical teams' NTS and their processes that may affect performance. Differences in self-reported teamwork and safety climate attitudes were also examined.Results In all, 186 procedures (100 before and 81 after hospital relocation) were observed across teams working in general, paediatric, orthopaedic and thoracic surgeries. Interobserver agreement ranged from 86% to 95%. An effect of phase was found, indicating that there were significant improvements after relocation in the use of NTS by the teams observed (P=0.020; 95% confidence interval 1.9-4.7).Conclusions The improvements seen in surgical teams' NTS performance and safety culture attitudes may be related to the move to a new state-of-the-art perioperative department.What is known about the topic? Patient safety in surgery relies on optimal team performance, underpinned by effective NTS.What does this paper add? The NTS of surgical teams may be improved through ergonomic innovations that promote teams' shared mental models.What are the implications for practitioners? Effective multidisciplinary teamwork relies on a combination of NTS and ergonomic factors, which inherently contribute to team performance and safety climate attitudes.

  14. Measured Results

    Science.gov (United States)

    Wiley, Frank N.

    2009-01-01

    Teachers have the "germiest" jobs in America. Only one professional can do anything about getting rid of germs once they have infected buildings: the school custodian. Custodians should be the first line of defense against pathogens in schools. Unfortunately, most are not trained or equipped to deal with this invisible world. Facility maintenance…

  15. Application of Molecular Typing Results in Source Attribution Models: The Case of Multiple Locus Variable Number Tandem Repeat Analysis (MLVA) of Salmonella Isolates Obtained from Integrated Surveillance in Denmark.

    Science.gov (United States)

    de Knegt, Leonardo V; Pires, Sara M; Löfström, Charlotta; Sørensen, Gitte; Pedersen, Karl; Torpdahl, Mia; Nielsen, Eva M; Hald, Tine

    2016-03-01

    Salmonella is an important cause of bacterial foodborne infections in Denmark. To identify the main animal-food sources of human salmonellosis, risk managers have relied on a routine application of a microbial subtyping-based source attribution model since 1995. In 2013, multiple locus variable number tandem repeat analysis (MLVA) substituted phage typing as the subtyping method for surveillance of S. Enteritidis and S. Typhimurium isolated from animals, food, and humans in Denmark. The purpose of this study was to develop a modeling approach applying a combination of serovars, MLVA types, and antibiotic resistance profiles for the Salmonella source attribution, and assess the utility of the results for the food safety decisionmakers. Full and simplified MLVA schemes from surveillance data were tested, and model fit and consistency of results were assessed using statistical measures. We conclude that loci schemes STTR5/STTR10/STTR3 for S. Typhimurium and SE9/SE5/SE2/SE1/SE3 for S. Enteritidis can be used in microbial subtyping-based source attribution models. Based on the results, we discuss that an adjustment of the discriminatory level of the subtyping method applied often will be required to fit the purpose of the study and the available data. The issues discussed are also considered highly relevant when applying, e.g., extended multi-locus sequence typing or next-generation sequencing techniques.

  16. Repeatability Evaluation of Finger Tapping Device with Magnetic Sensors

    Science.gov (United States)

    Sano, Yuko; Kandori, Akihiko; Shima, Keisuke; Tamura, Yasuhiro; Takagi, Hiroshi; Tsuji, Toshio; Noda, Masafumi; Higashikawa, Fumiko; Yokoe, Masaru; Sakoda, Saburo

    We tested the repeatability of a finger tapping device with magnetic sensors to determine its reliability. This device, which was developed to assist in the diagnosis of movement disorders such as Parkinson's disease (PD) and strokes, measures the distance between the first and index fingers during finger tapping movements (opening and closing the fingers repeatedly). We evaluated three types of repeatability based on ICC (interclass correlation coefficient) and Welch's test (test for equal means in a oneway layout): repeatability when measured at different times, when using different devices, and when using different measurers. We calculated these three types for three finger tapping tasks on both hands for 21 characteristics calculated from finger tapping waveforms. Results demonstrated that the repeatability when using different devices is high regardless of the task or hand. The repeatability when measuring at different times and when using different measurers is high at some tasks, but not all. One of the finger tapping tasks (finger tapping movement with the largest amplitude and highest velocity), which is used in a conventional PD diagnosis method (UPDRS), does not have enough repeatability, while other tasks show high repeatability. Results also showed that five characteristics have the highest repeatability (ICC ≥ 0.5 or significance probability of Welch's test ≥ 5% in all tasks): “total moving distance,” “average of local minimum acceleration in opening motion,” “average of local minimum acceleration in closing motion,” “average of local maximum distance” and “average of local minimum velocity”. These results clearly demonstrate the strong repeatability of this device and lead to more precise diagnosis of movement disorders.

  17. Quantum Key Distribution over Probabilistic Quantum Repeaters

    CERN Document Server

    Amirloo, Jeyran; Majedi, A Hamed

    2010-01-01

    A feasible route towards implementing long-distance quantum key distribution (QKD) systems relies on probabilistic schemes for entanglement distribution and swapping as proposed in the work of Duan, Lukin, Cirac, and Zoller (DLCZ) [Nature 414, 413 (2001)]. Here, we calculate the conditional throughput and fidelity of entanglement for DLCZ quantum repeaters, by accounting for the DLCZ self-purification property, in the presence of multiple excitations in the ensemble memories as well as loss and other sources of inefficiency in the channel and measurement modules. We then use our results to find the generation rate of secure key bits for QKD systems that rely on DLCZ quantum repeaters. We compare the key generation rate per logical memory employed in the two cases of with and without a repeater node. We find the cross-over distance beyond which the repeater system outperforms the non-repeater one. That provides us with the optimum inter-node distancing in quantum repeater systems. We also find the optimal exci...

  18. Lumbar spine and pelvic posture between standing and sitting: a radiologic investigation including reliability and repeatability of the lumbar lordosis measure.

    Science.gov (United States)

    De Carvalho, Diana E; Soave, David; Ross, Kim; Callaghan, Jack P

    2010-01-01

    Sitting has been identified as a cause of mechanical low back pain. The purpose of this study was to use plain film x-rays to measure lumbar spine and pelvic posture differences between standing and sitting. Eight male subjects were radiographed standing and sitting in an automobile seat. Measures of lumbar lordosis, intervertebral disk angles, lumbosacral angle, lumbosacral lordosis, and sacral tilt were completed. One-way analysis of variance (alpha = .05) was conducted on the variables stated above. A Bland-Altman analysis was conducted to assess agreement and repeatability of the lumbar lordosis angle using 2 raters. Lumbar lordosis values in standing (average, 63 degrees +/- 15 degrees ) and sacral inclination (average, 43 degrees +/- 10 degrees ) decreased by 43 degrees and 44 degrees , respectively, in sitting. Intervertebral joint angles in sitting underwent substantial flexion (L1/L2-5 degrees [+/-3 degrees ], L2/L3-7 degrees [+/-3 degrees ], L3/L4-8 degrees [+/-3 degrees ], L4/L5-13 degrees [+/-3 degrees ], and L5/S1-4 degrees [+/-10 degrees ]). Measures of lumbar lordosis; intervertebral disk angles between L2/L3, L3/L4, and L4/L5; lumbosacral lordosis; lumbosacral angle; and sacral tilt were significantly decreased between standing and sitting (P posture should be investigated because they may play a role in preventing injury and low back pain. Copyright 2010 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.

  19. Effectiveness of two strategies to follow-up ASC-US and LSIL screening results in The Netherlands using repeat cytology with or without additional hrHPV testing: a retrospective cohort study

    NARCIS (Netherlands)

    Siebers, A.G.; Arbyn, M.; Melchers, W.J.; Kemenade, F.J. van; Vedder, J.E.; Linden, H. van der; Ballegooijen, M. van; Bekkers, R.L.; Bulten, J.

    2014-01-01

    PURPOSE: The purpose of the study was to assess the effectiveness of repeat cytology with and without additional high-risk human papilloma virus (hrHPV) testing after atypical squamous cells of undetermined significance/low-grade squamous intraepithelial lesion (ASC-US/LSIL) screening results.

  20. An exploration of measures for comparing measurements with the results from meteorological models for Mexico City

    Energy Technology Data Exchange (ETDEWEB)

    Williams, M.D.; Brown, M.J.

    1995-12-31

    Los Alamos National Laboratory and Instituto Mexicano del Petroleo have completed a joint study of options for improving air quality in Mexico City. We used a three-dimensional, prognostic, higher-order turbulence model for atmospheric circulation (HOTMAC) to treat domains that include an urbanized area. We tested the model against routine measurements and those of a major field program. During the field program, measurements included: (1) lidar measurements of aerosol transport and dispersion, (2) aircraft measurements of winds, turbulence, and chemical species aloft, (3) aircraft measurements of skin temperatures, and (4) Tethersonde measurements of winds and ozone. We made both graphical and statistical comparisons and we have reported some of the comparisons to provide insight into the meaning of statistical parameters including the index of agreement.

  1. Influence of beverage composition on the results of erosive potential measurement by different measurement techniques.

    NARCIS (Netherlands)

    Jager, D.H.; Vieira, A.M.; Ruben, J.L.; Huysmans, M.C.D.N.J.M.

    2008-01-01

    The influence of beverage composition on the measurement of erosive potential is unclear. The aim of this study was to evaluate whether beverage composition influences the measurement of erosive potential and to evaluate the influence of exposure in small and large volumes. Eleven beverages were inc

  2. Influence of beverage composition on the results of erosive potential measurement by different measurement techniques

    NARCIS (Netherlands)

    Jager, D. H. J.; Vieira, A. M.; Ruben, J. L.; Huysmans, M. C. D. N. J. M.

    2008-01-01

    The influence of beverage composition on the measurement of erosive potential is unclear. The aim of this study was to evaluate whether beverage composition influences the measurement of erosive potential and to evaluate the influence of exposure in small and large volumes. Eleven beverages were inc

  3. THE SYSTEM APPROACH TO MEASURING CHANNEL MODELLING AS THE MECHANISM OF MAINTENANCE OF TRUST TO RESULTS OF MEASUREMENTS

    Directory of Open Access Journals (Sweden)

    P. S. Serenkov

    2012-01-01

    Full Text Available Necessity of system approach development to measurement modeling for the purpose of maintenance of the trust set level to their results is proved. The decision of a measuring problem subject to determined aim is considered as creation of models sequence: measurement process model and complex measuring channel model. As a demonstrative basis of maintenance of trust to result of measurements the complex of criteria of completeness and irredundant is formulated.

  4. Seasonal variation in objectively measured physical activity, sedentary time, cardio-respiratory fitness and sleep duration among 8–11 year-old Danish children: a repeated-measures study

    DEFF Research Database (Denmark)

    Hjorth, Mads F.; Chaput, Jean-Philippe; Michaelsen, Kim;

    2013-01-01

    BACKGROUND: Understanding fluctuations in lifestyle indicators is important to identify relevant time periods to intervene in order to promote a healthy lifestyle; however, objective assessment of multiple lifestyle indicators has never been done using a repeated-measures design. The primary aim...... was, therefore, to examine between-season and within-week variation in physical activity, sedentary behaviour, cardio-respiratory fitness and sleep duration among 8–11 year-old children. METHODS: A total of 1021 children from nine Danish schools were invited to participate and 834 accepted. Due...

  5. Evaluation of the running-based anaerobic sprint test as a measure of repeated sprint ability in collegiate-level soccer players.

    Science.gov (United States)

    Keir, Daniel A; Thériault, Francis; Serresse, Olivier

    2013-06-01

    Repeated sprint ability (RSA) refers to an individual's ability to perform maximal sprints of short duration in succession with little recovery between sprints. The running-based anaerobic sprint test (RAST) has been adapted from the Wingate anaerobic test (WAnT) protocol as a tool to assess RSA and anaerobic power. The purpose of this study was to evaluate the relationship between performance variables and physiological responses obtained during the RAST and the WAnT using 8 collegiate-level soccer players. Participants performed a single trial of both the WAnT and the RAST. Breath-by-breath gas exchange was monitored throughout each trial, and blood lactate (BL) measures were recorded postexercise. The oxygen uptake (VO2) profile suggested that the RAST required greater contributions from aerobic metabolism although there was no difference in VO2peak (p < 0.05). Peak BL values were also similar between the RAST and the WAnT (p < 0.05). Neither peak physiological values nor performance variables (peak and mean power) were significantly correlated between protocols. The weak association in physiological responses indicates that different combinations of metabolic contributions exist between protocols, suggesting that individual performances on each test are not related in collegiate soccer players. Further studies on these relationships with players of other competitive levels and team sport athletes are warranted.

  6. Knowledge and skill retention of in-service versus preservice nursing professionals following an informal training program in pediatric cardiopulmonary resuscitation: a repeated-measures quasiexperimental study.

    Science.gov (United States)

    Sankar, Jhuma; Vijayakanthi, Nandini; Sankar, M Jeeva; Dubey, Nandkishore

    2013-01-01

    Our objective was to compare the impact of a training program in pediatric cardiopulmonary resuscitation (CPR) on the knowledge and skills of in-service and preservice nurses at prespecified time points. This repeated-measures quasiexperimental study was conducted in the pediatric emergency and ICU of a tertiary care teaching hospital between January and March 2011. We assessed the baseline knowledge and skills of nursing staff (in-service nurses) and final year undergraduate nursing students (preservice nurses) using a validated questionnaire and a skill checklist, respectively. The participants were then trained on pediatric CPR using standard guidelines. The knowledge and skills were reassessed immediately after training and at 6 weeks after training. A total of 74 participants-28 in-service and 46 preservice professionals-were enrolled. At initial assessment, in-service nurses were found to have insignificant higher mean knowledge scores (6.6 versus 5.8, P = 0.08) while the preservice nurses had significantly higher skill scores (6.5 versus 3.2, P nurses performing better in knowledge test (10.5 versus 9.1, P = 0.01) and the preservice nurses performing better in skill test (9.8 versus 7.4, P skills of in-service and preservice nurses in pediatric CPR improved with training. In comparison to preservice nurses, the in-service nurses seemed to retain knowledge better with time than skills.

  7. Direct and accurate measurement of CAG repeat configuration in the ataxin-1 (ATXN-1) gene by "dual-fluorescence labeled PCR-restriction fragment length analysis".

    Science.gov (United States)

    Lin, Jiang X; Ishikawa, Kinya; Sakamoto, Masaki; Tsunemi, Taiji; Ishiguro, Taro; Amino, Takeshi; Toru, Shuta; Kondo, Ikuko; Mizusawa, Hidehiro

    2008-01-01

    Spinocerebellar ataxia type 1 (SCA1; OMIM: #164400) is an autosomal dominant cerebellar ataxia caused by an expansion of CAG repeat, which encodes polyglutamine, in the ataxin-1 (ATXN1) gene. Length of polyglutamine in the ATXN1 protein is the critical determinant of pathogenesis of this disease. Molecular diagnosis of SCA1 is usually undertaken by assessing the length of CAG repeat configuration using primers spanning this configuration. However, this conventional method may potentially lead to misdiagnosis in assessing polyglutamine-encoding CAG repeat length, since CAT interruptions may be present within the CAG repeat configuration, not only in normal controls but also in neurologically symptomatic subjects. We developed a new method for assessing actual CAG repeat numbers not interrupted by CAT sequences. Polymerase chain reaction using a primer pair labeled with two different fluorescences followed by restriction enzyme digestion with SfaNI which recognizes the sequence "GCATC(N)(5)", lengths of actual CAG repeats that encode polyglutamine were directly detected. We named this method "dual fluorescence labeled PCR-restriction fragment length analysis". We found that numbers of actual CAG repeat encoding polyglutamine do not overlap between our cohorts of normal chromosomes (n=385) and SCA1 chromosomes (n=5). We conclude that the present method is a useful way for molecular diagnosis of SCA1.

  8. Automatization and familiarity in repeated checking

    NARCIS (Netherlands)

    Dek, Eliane C P; van den Hout, Marcel A.; Giele, Catharina L.; Engelhard, Iris M.

    2014-01-01

    Repeated checking paradoxically increases memory uncertainty. This study investigated the underlying mechanism of this effect. We hypothesized that as a result of repeated checking, familiarity with stimuli increases, and automatization of the checking procedure occurs, which should result in decrea

  9. Quantitative repeated open application testing with a rinse-off product in methyldibromo glutaronitrile-sensitive patients: results of the IVDK.

    Science.gov (United States)

    Heratizadeh, Annice; Killig, Claudia; Worm, Margitta; Soost, Stephanie; Simon, Dagmar; Bauer, Andrea; Mahler, Vera; Schuster, Christian; Szliska, Christiane; Frambach, Yvonne; Eben, Ricarda; Werfel, Thomas; Uter, Wolfgang; Schnuch, Axel

    2010-06-01

    While the use of methyldibromo glutaronitrile (MDBGN) in leave-on products is clearly associated with high sensitization or elicitation risk, such a clear-cut relation could be questioned with regard to rinse-off products. The objective of this study was to find a maximum non-eliciting concentration for rinse-off products in MDBGN patch test-positive patients. We performed a use-related test [repeated open application test (ROAT)] in patients sensitized to MDBGN with a liquid soap containing three concentrations of MDBGN (50, 200, and 400 p.p.m. MDBGN, respectively). The soap at 50 p.p.m. was used twice daily for 4 weeks. If no reaction of the skin was observed, the product with the next higher concentration was used for another 4 weeks, etc. In total, 32/37 evaluated cases [86.5%; lower exact one-sided 95% confidence limit (CL): 73.7%] did not react to any of the preparations. The remaining reacted as follows: 1/37 reacted to 50 p.p.m., 3/37 to 200 p.p.m., and 1/37 to 400 p.p.m. The cumulative non-response to 50 p.p.m. was 97.3% (lower CL: 87.8%). The majority of subjects sensitized to MDBGN-tolerated rinse-off products containing a maximum concentration of 400 p.p.m. A concentration in rinse-off products in the range of 50 p.p.m. could be regarded as safe for most individuals already sensitized. These concentrations will presumably prevent induction (sensitization) also.

  10. Telomere shortening unrelated to smoking, body weight, physical activity, and alcohol intake: 4,576 general population individuals with repeat measurements 10 years apart.

    Directory of Open Access Journals (Sweden)

    Maren Weischer

    2014-03-01

    Full Text Available Cross-sectional studies have associated short telomere length with smoking, body weight, physical activity, and possibly alcohol intake; however, whether these associations are due to confounding is unknown. We tested these hypotheses in 4,576 individuals from the general population cross-sectionally, and with repeat measurement of relative telomere length 10 years apart. We also tested whether change in telomere length is associated with mortality and morbidity in the general population. Relative telomere length was measured with quantitative polymerase chain reaction. Cross-sectionally at the first examination, short telomere length was associated with increased age (P for trend across quartiles = 3 × 10(-77, current smoking (P = 8 × 10(-3, increased body mass index (P = 7 × 10(-14, physical inactivity (P = 4 × 10(-17, but not with increased alcohol intake (P = 0.10. At the second examination 10 years later, 56% of participants had lost and 44% gained telomere length with a mean loss of 193 basepairs. Change in leukocyte telomere length during 10 years was associated inversely with baseline telomere length (P<1 × 10(-300 and age at baseline (P = 1 × 10(-27, but not with baseline or 10-year inter-observational tobacco consumption, body weight, physical activity, or alcohol intake. Prospectively during a further 10 years follow-up after the second examination, quartiles of telomere length change did not associate with risk of all-cause mortality, cancer, chronic obstructive pulmonary disease, diabetes mellitus, ischemic cerebrovascular disease, or ischemic heart disease. In conclusion, smoking, increased body weight, and physical inactivity were associated with short telomere length cross-sectionally, but not with telomere length change during 10 years observation, and alcohol intake was associated with neither. Also, change in telomere length did not associate prospectively with mortality or morbidity in the general population.

  11. Joint modeling of repeated multivariate cognitive measures and competing risks of dementia and death: a latent process and latent class approach.

    Science.gov (United States)

    Proust-Lima, Cécile; Dartigues, Jean-François; Jacqmin-Gadda, Hélène

    2016-02-10

    Joint models initially dedicated to a single longitudinal marker and a single time-to-event need to be extended to account for the rich longitudinal data of cohort studies. Multiple causes of clinical progression are indeed usually observed, and multiple longitudinal markers are collected when the true latent trait of interest is hard to capture (e.g., quality of life, functional dependency, and cognitive level). These multivariate and longitudinal data also usually have nonstandard distributions (discrete, asymmetric, bounded, etc.). We propose a joint model based on a latent process and latent classes to analyze simultaneously such multiple longitudinal markers of different natures, and multiple causes of progression. A latent process model describes the latent trait of interest and links it to the observed longitudinal outcomes using flexible measurement models adapted to different types of data, and a latent class structure links the longitudinal and cause-specific survival models. The joint model is estimated in the maximum likelihood framework. A score test is developed to evaluate the assumption of conditional independence of the longitudinal markers and each cause of progression given the latent classes. In addition, individual dynamic cumulative incidences of each cause of progression based on the repeated marker data are derived. The methodology is validated in a simulation study and applied on real data about cognitive aging obtained from a large population-based study. The aim is to predict the risk of dementia by accounting for the competing death according to the profiles of semantic memory measured by two asymmetric psychometric tests.

  12. On results using automated wideband instrumentation for radar measurements and characterization

    Science.gov (United States)

    Govoni, Mark A.; Dogaru, Traian; Le, Calvin; Sobczak, Kevin

    2017-05-01

    Experiences are shared from a recent radar measurement and characterization effort. A regimented data collection procedure ensures repeatability and provides an expedited alternative to typical narrowband capabilities. Commercially-available instrumentation is repurposed to support wideband data collections spanning a contiguous range of frequencies from 700 MHz to 40 GHz. Utilizing a 4-port network analyzer, both monostatic and quasi-monostatic measurements are achievable. Polarization is varied by way of a custom-designed antenna mount that allows for the mechanical reorientation of the antennas. Computational electromagnetic modeling is briefly introduced and serves in validating the legitimacy of the collection capability. Data products presented will include high-range resolution profiles and inverse synthetic aperture radar (ISAR) imagery.

  13. Corneal topography measurement by means of radial shearing interference: Part II - experiment results

    Science.gov (United States)

    Garncarz, Beata E.; Kowalik, Waldemar W.; Kasprzak, Henryk T.

    The method of the measurement of the corneal topography was worked out. This measurement system uses an interferometer based on radial shearing. This paper presents the preliminary results of the experiments. The results are compared with other methods.

  14. Keeping Confidence in Data over Time: Testing the Tenor of Results from Repeat Administrations of a Question Inventory. Professional File. Number 121, Summer 2011

    Science.gov (United States)

    Boylan, Ellen

    2011-01-01

    The following describes research supported by the Teagle Foundation for the development and testing of an instrument for measuring college student perceptions of institutional mission in the learning environment. Findings from reliability and validity testing of a set of questions called the Mission Perception Inventory (MPI) are discussed. The…

  15. Understanding CMMI Measurement Capabilities & Impact on Performance: Results from the 2007 SEI State of the Measurement Practice Survey

    Science.gov (United States)

    2016-06-30

    Practice Survey New this year • Screening question to identify respondents whose organizations develop software but rarely if ever do measurement...Questions about — Resources & infrastructure devoted to measurement — Practices to ensure data quality & integrity — Value added by doing measurement — The...University Project & Organizational Measurement Results Reported2 Business Growth & Profitability ML1&DK ML2 ML3 ML4&5 N = 70 N = 55 N = 45 N = 51

  16. An evaluation of a structured learning program as a component of the clinical practicum in undergraduate nurse education: A repeated measures analysis.

    Science.gov (United States)

    Watt, Elizabeth; Murphy, Maria; MacDonald, Lee; Pascoe, Elizabeth; Storen, Heather; Scanlon, Andrew

    2016-01-01

    There is evidence that nursing students experience stress and anxiety and a reduction in self-efficacy when undertaking clinical placements. Previous reports have identified that a structured three-day program within the Bachelor of Nursing (BN) clinical practicum reduces the students self-report of anxiety and increases self-efficacy. However, it is unreported whether these improved outcomes are sustained for the duration of the clinical placement. The aim of this study was to evaluate the duration of the effect of a three-day structured learning program within the clinical placement on final year Bachelor of Nursing student's report of anxiety and self-efficacy pre- and post-program participation in this intervention and following completion of the clinical practicum. A repeated measures design. University-based Clinical School of Nursing, acute care clinical practicum. Final year Bachelor of Nursing students. The intervention comprised the three-day program on starting the clinical practicum. A questionnaire included the anxiety subscale of The Hospital Anxiety & Depression Scale (The HAD) and the General Self-Efficacy Scale (GSES-12). The questionnaire was completed on day one (time one), upon completion of the three-day program (time two) and upon completion of placement on day 18 (time three). The questionnaire response rate varied over time. There was a statistically significant effect in reducing anxiety over time: F(1.73,74.46)=25.20, plearning program and the benefit of the intervention is sustained for the clinical placement duration. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Repeat fine-needle aspiration can be performed at 6 months or more after initial atypia of undetermined significance or follicular lesion of undetermined significance results for thyroid nodules 10 mm or larger.

    Science.gov (United States)

    Koh, Jieun; Kim, Eun-Kyung; Kwak, Jin Young; Yoon, Jung Hyun; Moon, Hee Jung

    2016-12-01

    To investigate whether repeat ultrasound-guided fine-needle aspiration (US-FNA) in initial atypia of undetermined significance or follicular lesion of undetermined significance (AUS/FLUS) results could be performed 6 months after or more. A total of 221 AUS/FLUS ≥10 mm with any follow-up were grouped according to the first follow-up interval at less than 6 months (group 1, n = 87) and 6 months or more (group 2, n = 134). Clinical features, final assessment of ultrasound (US) or the Thyroid Imaging Reporting and Data System (TIRADS), tumour size, extrathyroidal extension and lymph node metastasis in malignancies were compared. Thirty-four (15.4 %) were malignant. Age, gender, size, final assessment, TIRADS and malignancy rate were not significantly different between the two groups (p = 0.660, 0.691, 0.502, 0.237, 0.819 and 0.420). Tumour size, extrathyroidal extension and lymph node metastasis were not significantly different between the two malignancy groups (p = 0.770, 0.611 and 0.068). Two of 10 nodules with increased size were malignancies found at 7.1 and 25.0 months. None of 33 nodules (14.9 %) with decreased size at a median 10 months were malignant. Repeat US-FNA performed on nodules ≥10 mm at 6 months or more after initial AUS/FLUS results can reduce unnecessary repeat US-FNAs without progression of malignancy. • Follow-up intervals of AUS/FLUS did not affect the malignancy rate • Tumour stage was not different according to the follow-up intervals • None of the nodules with decreased size were malignant • Repeat US-FNA can be performed at ≥6 months after initial AUS/FLUS.

  18. Detection of the effects of repeated dose combined propoxur and heavy metal exposure by measurement of certain toxicological, haematological and immune function parameters in rats.

    Science.gov (United States)

    Institóris, L; Siroki, O; Undeger, U; Basaran, N; Banerjee, B D; Dési, I

    2001-06-21

    In the present study, an immunotoxicity test system, containing general toxicological (body weight gain, organ weights), haematological (WBC,RBC, Ht, mean cell volume of the RBCs, cell content of the femoral bone marrow), and immune function (PFC assay, DTH reaction) investigations, was used for detection the effects of a 4 weeks repeated low dose combined oral exposure of male Wistar rats with propoxur and the heavy metals arsenic or mercury. Two doses of the compounds were used: a higher one (the lowest dose which resulted in significant change of at least one parameter examined in previous dose-effect experiments), and a lower one (the highest dose which proved to be non-effective). The applied doses were: 8.51 and 0.851 mg kg(-1) of propoxur, 13.3 and 3.33 mg kg(-1) of NaAsO(2), and 3.20 and 0.40 mg kg(-1) of HgCl(2). In the combination treatment, the high dose of propoxur was combined with the low dose of arsenic or mercury, and the high doses of each heavy metals were combined with the low dose of propoxur. The main finding of this study was that some of the combinations significantly altered the relative weight of liver, adrenals and kidneys, related to both the untreated and the high dose internal control. Among the immune functions examined, only the PFC content of the spleen showed a trend of changes in certain combinations versus the corresponding high dose control. According to the present results, combined exposure with propoxur and the heavy metals examined can modify the detection limit of the single compounds and/or may alter their toxic effects.

  19. Results of kidney function measurement and blood pressure in population from endemic region of Vitina

    Directory of Open Access Journals (Sweden)

    Stašević Zvonimir

    2008-01-01

    Full Text Available Introduction. The analysis of frequency of kidney diseases, causes of terminal renal failure in patients subjected to repeated dialysis in major dialysis centers in the region of Kosovo and Metohija as well as mortality rate in these patients showed a stable number of patients with kidney diseases, evidencing that the populations of Vitina and Gnjilane were the most commonly affected. These towns are designated as regions with the highest incidence of Balkan endemic nephropathy. The present analysis was aimed at: 1. establishing the incidence rate of hypertension and renal function impairment by using clinical and laboratory analyses in individuals from Vitina and neighboring villages, and 2. investigating the correlation between creatinine clearance, age and arterial blood pressure in the studied group. Material and methods. The analysis included 510 individuals (excluding diabetics over the one-month period during 2004 (201 males with their age ranging from 18 to 90 years. Blood pressure measurements were performed in all the individuals, while renal function was determined by glomerular filtration rate (GFR, as calculated according to Cockcroft-Gault formula. Results. Creatinine clearance was lower than 100 ml/min in 237 (46.5% individuals, out of whom 62 (12% had GFR below 60 ml/min. Among the remaining 273 (53.5% individuals with GFR above 100 ml/min, 68 individuals had GFR above 140 ml/min. The distribution of patients depending on their systolic blood pressure values revealed that systolic blood pressure was lower in 44 subjects and higher in 302 subjects (59%. The correlation test revealed significant association between the studied parameters. The positive correlation between patients' age and kidney function means the higher the age of subjects the lower creatinine clearance value (r=-0.622, p<0.001. The negative correlation of the systolic blood pressure value and kidney function was found, meaning that higher the systolic blood

  20. Results of radiometric ash-content measurements at the Dudar coal mine, Hungary

    Energy Technology Data Exchange (ETDEWEB)

    Csoti, T. (Veszpremi Szenbanyak Dudari Banyauezeme, Dudar (Hungary))

    1983-12-01

    The regression analysis of the results of calorimetric and radiometric ash-content measurements of 1239 coal samples have shown that the calorific values which cannot be measured easily with traditional means can be approximated reasonably from the more easily measured radiometric data. The introduction of the radiometric measurements can be recommended for coal deposits. 6 refs.

  1. Soil acidification occurs under ambient conditions but is retarded by repeated drought: results of a field-scale climate manipulation experiment

    NARCIS (Netherlands)

    G.R. Kopittke; A. Tietema; J.M. Verstraten

    2012-01-01

    Acid atmospheric emissions within Europe and North America have decreased strongly since 1985 and most recent acidification studies have focused on the changes occurring within ecosystems as a result of this decreased deposition. This current study documents a soil acidification trend under ambient

  2. Safety of Repeated Yttrium-90 Radioembolization

    Energy Technology Data Exchange (ETDEWEB)

    Lam, Marnix G. E. H.; Louie, John D. [Stanford University School of Medicine, Division of Interventional Radiology (United States); Iagaru, Andrei H.; Goris, Michael L. [Stanford University School of Medicine, Division of Nuclear Medicine (United States); Sze, Daniel Y., E-mail: dansze@stanford.edu [Stanford University School of Medicine, Division of Interventional Radiology (United States)

    2013-10-15

    Purpose: Repeated radioembolization (RE) treatments carry theoretically higher risk of radiation-induced hepatic injury because of the liver's cumulative memory of previous exposure. We performed a retrospective safety analysis on patients who underwent repeated RE. Methods: From 2004 to 2011, a total of 247 patients were treated by RE. Eight patients (5 men, 3 women, age range 51-71 years) underwent repeated treatment of a targeted territory, all with resin microspheres (SIR-Spheres; Sirtex, Lane Cove, Australia). Adverse events were graded during a standardized follow-up. In addition, the correlation between the occurrence of RE-induced liver disease (REILD) and multiple variables was investigated in univariate and multivariate analyses in all 247 patients who received RE. Results: Two patients died shortly after the second treatment (at 84 and 107 days) with signs and symptoms of REILD. Both patients underwent whole liver treatment twice (cumulative doses 3.08 and 2.66 GBq). The other 6 patients demonstrated only minor toxicities after receiving cumulative doses ranging from 2.41 to 3.88 GBq. All patients experienced objective tumor responses. In the whole population, multifactorial analysis identified three risk factors associated with REILD: repeated RE (p = 0.036), baseline serum total bilirubin (p = 0.048), and baseline serum aspartate aminotransferase (p = 0.043). Repeated RE proved to be the only independent risk factor for REILD in multivariate analysis (odds ratio 9.6; p = 0.002). Additionally, the administered activity per target volume (in GBq/L) was found to be an independent risk factor for REILD, but only in whole liver treatments (p = 0.033). Conclusion: The risk of REILD appears to be elevated for repeated RE. Objective tumor responses were observed, but establishment of safety limits will require improvement in dosimetric measurement and prediction.

  3. Performance Prismas an Innovative Concept of the Organizational Activity Results Measurement

    Directory of Open Access Journals (Sweden)

    Arkadiusz Jagiełło

    2010-06-01

    Full Text Available The article presents an innovative method of the organization activity results measurement which is called Performance Measurement System. It is kind of control system which can help to improve the competitive advantages of organization.

  4. 超高分辨率OCT角膜上皮厚度自动测量的重复性研究%Study of repeatability of corneal epithelium thickness profiles automatically measured by ultra -high resolution OCT system

    Institute of Scientific and Technical Information of China (English)

    徐肃仲; 叶欣杰; 许哲; 杨纯; 沈梅晓

    2013-01-01

    目的:研究基于自动分层算法的超高分辨率谱域 OCT ( UHR-OCT)用于角膜上皮厚度测量的重复性。  方法:使用自行搭建的UHR-OCT系统采集18例健康受试者(年龄23.2±0.9岁)左眼的图像,应用一种基于轴向梯度信息和最短路径的分层算法对得到的SD-OCT图像进行边界探测获取角膜上皮厚度。  结果:自动与手动的上皮分层的位置有很好的相关性(P>0.05,配对t检验)。自动算法获取的6 mm范围平均上皮厚度为52.1±2.1μm,范围从50.3±1.8μm 到53.2±2.4μm,与手动分层之间的角膜上皮厚度差异为0.4±0.3μm。UHR-OCT自动算法重复测量上皮厚度的组内相关系数ICC和可重复性系数CoR分别为0.90±0.05,1.44±0.01μm。  结论:对于超高分辨率OCT,自动分层方法在角膜上皮厚度测量中有着很好的准确性和可重复性。%AIM:To assess the repeatability of thickness profiles of corneal epithelium produced by aautomatic hierarchic algorithm that was applied to images obtained by a custom-built ultra-high resolution OCT ( UHR-OCT ) system. METHODS:Eighteen left eyes of 18 subjects (23.2±0.9) years;mean age±standard deviation) were imaged twice on non-consecutive days by a custom-built ultra-high resolution OCT ( UHR -OCT ) system. A hierarchic algorithm based on the axial gradient information and a shortest path search was developed to measure the corneal epithelial thickness profiles from the SD-OCT images. RESULTS: There was good correlation between theautomatic and manual hierarchy positions of the epithelium ( p >0.05, paired t -test ). The average epithelial thickness of the 6mm central corneal region determined by the automatic hierarchic algorithm was 52.1±2.1μm, ranging from 50.3 ±1.8μm to 53.2 ±2.4μm along the horizontal meridian. The epithelial thickness differences between automatic and manual hierarchy by the UHR-OCT systems were 0.4 ±0

  5. Association of Repeatedly Measured High-Sensitivity-Assayed Troponin I with Cardiovascular Disease Events in a General Population from the MORGAM/BiomarCaRE Study

    DEFF Research Database (Denmark)

    Hughes, Maria F; Ojeda, Francisco; Saarela, Olli;

    2017-01-01

    BACKGROUND: High-sensitivity troponin I (hs-cTnI) concentrations reflect myocardial stress. The role of hs-cTnI in predicting long-term changes in the risk of cardiovascular disease (CVD) in general populations is not clearly defined. METHODS: We investigated whether the change in 3 repeated meas...

  6. Repeated electromagnetic induction measurements for mapping soil moisture at the field scale: comparison with data from a wireless soil moisture monitoring network

    Science.gov (United States)

    Martini, Edoardo; Werban, Ulrike; Zacharias, Steffen; Pohle, Marco; Dietrich, Peter; Wollschläger, Ute

    2016-04-01

    Electromagnetic induction (EMI) methods are widely used for soil mapping, as they allow fast and relatively low-cost surveys of soil apparent electrical conductivity (ECa) at various scales. Soil ECa is well known to be influenced by both the volumetric content and the electrical conductivity (EC) of soil water, as well as by soil temperature and by the volume of the solid particles and their EC. Among other applications, EMI has become widely used to determine soil water content or to study hydrological processes within the field of hydrogeophysics. Although the use of non-invasive EMI for imaging soil spatial properties is very attractive, the dependence of ECa on several properties and states challenges any interpretation with respect to individual soil properties or states such as θ. The major aim of this study was to further investigate the potential of repeated EMI measurements to map soil moisture at the hillslope scale, with particular focus on the temporal variability of the spatial patterns of ECa and soil moisture, respectively, and on the stability of the ECa-soil moisture relationship over time. To this end, we compared time series of EMI measurements with high-resolution soil moisture data for a non-intensively managed hillslope area in the Schäfertal catchment (Central Germany) for which the spatial distribution of soil properties and soil water dynamics were known in detail. Soil water and temperature dynamics were observed in 40 soil profiles at hourly resolution during 14 months using a wireless monitoring network. During this period of time, ECa was mapped on seven occasions using an EM38-DD device. For the investigated site, ECa showed small temporal variations (ranging between 0 and 24 mS/m) whereas the temporal range of soil moisture was very large (from very dry to soil saturation). Furthermore, temporal changes of the spatial pattern of ECa differed from temporal changes of the spatial pattern of soil moisture. The ECa-soil moisture

  7. Left-right olfactory asymmetry results from antagonistic functions of voltage-activated calcium channels and the Raw repeat protein OLRN-1 in C. elegans

    Directory of Open Access Journals (Sweden)

    Katsura Isao

    2007-11-01

    Full Text Available Abstract Background The left and right AWC olfactory neurons in Caenorhabditis elegans differ in their functions and in their expression of chemosensory receptor genes; in each animal, one AWC randomly takes on one identity, designated AWCOFF, and the contralateral AWC becomes AWCON. Signaling between AWC neurons induces left-right asymmetry through a gap junction network and a claudin-related protein, which inhibit a calcium-regulated MAP kinase pathway in the neuron that becomes AWCON. Results We show here that the asymmetry gene olrn-1 acts downstream of the gap junction and claudin genes to inhibit the calcium-MAP kinase pathway in AWCON. OLRN-1, a protein with potential membrane-association domains, is related to the Drosophila Raw protein, a negative regulator of JNK mitogen-activated protein (MAP kinase signaling. olrn-1 opposes the action of two voltage-activated calcium channel homologs, unc-2 (CaV2 and egl-19 (CaV1, which act together to stimulate the calcium/calmodulin-dependent kinase CaMKII and the MAP kinase pathway. Calcium channel activity is essential in AWCOFF, and the two AWC neurons coordinate left-right asymmetry using signals from the calcium channels and signals from olrn-1. Conclusion olrn-1 and voltage-activated calcium channels are mediators and targets of AWC signaling that act at the transition between a multicellular signaling network and cell-autonomous execution of the decision. We suggest that the asymmetry decision in AWC results from the intercellular coupling of voltage-regulated channels, whose cross-regulation generates distinct calcium signals in the left and right AWC neurons. The interpretation of these signals by the kinase cascade initiates the sustained difference between the two cells.

  8. Interlaboratory comparison of measuring results of magnetic field near 400 kV overhead power line

    Directory of Open Access Journals (Sweden)

    Grbić Maja

    2012-01-01

    Full Text Available The paper presents a comparison of measured results of magnetic field near 400 kV overhead power lines obtained by three laboratories. This interlaboratory comparison was performed to ensure confidence in the quality of the test results. The measured results were analyzed with standard methods, using En number, based on which the evaluation of the laboratories was performed.

  9. Results of repeat bathymetric and velocimetric surveys at the Amelia Earhart Bridge on U.S. Highway 59 over the Missouri River at Atchison, Kansas, 2009-2013

    Science.gov (United States)

    Huizinga, Richard J.

    2013-01-01

    Bathymetric and velocimetric data were collected six times by the U.S. Geological Survey, in cooperation with the Kansas Department of Transportation, in the vicinity of Amelia Earhart Bridge on U.S. Highway 59 over the Missouri River at Atchison, Kansas. A multibeam echosounder mapping system and an acoustic Doppler current meter were used to obtain channel-bed elevations and depth-averaged velocities for a river reach approximately 2,300 feet long and extending across the active channel of the Missouri River. The bathymetric and velocimetric surveys provide a “snapshot” of the channel conditions at the time of each survey, and document changes to the channel-bed elevations and velocities during the course of construction of a new bridge for U.S. Highway 59 downstream from the Amelia Earhart Bridge. The baseline survey in June 2009 revealed substantial scour holes existed at the railroad bridge piers upstream from and at pier 10 of the Amelia Earhart Bridge, with mostly uniform flow and velocities throughout the study reach. After the construction of a trestle and cofferdam on the left (eastern) bank downstream from the Amelia Earhart Bridge, a survey on June 2, 2010, revealed scour holes with similar size and shape as the baseline for similar flow conditions, with slightly higher velocities and a more substantial contraction of flow near the bridges than the baseline. Subsequent surveys during flooding conditions in June 2010 and July 2011 revealed substantial scour near the bridges compared to the baseline survey caused by the contraction of flow; however, the larger flood in July 2011 resulted in less scour than in June 2010, partly because the removal of the cofferdam for pier 5 of the new bridge in March 2011 diminished the contraction near the bridges. Generally, the downstream part of the study reach exhibited varying amounts of scour in all of the surveys except the last when compared to the baseline. During the final survey, velocities throughout the

  10. Evaluation of quality assurance calibration results based on repeated calibrations; Evaluacion del aseguramiento de la calidad de los resultados de calibracion en base a la repeticion de las calibraciones

    Energy Technology Data Exchange (ETDEWEB)

    Mestre de Juan, V.; Albau Albos, J.; Gomez Llobat, L.

    2011-07-01

    To ensure quality assurance of the calibration results, as indicated by the UNE-EN ISO / IEC 17025:2005 in paragraph 5.9, the laboratory has established procedures for quality control of its activity. Thus, the laboratory participates in both inter-laboratory intercomparison exercises, cycle through the entire range of radiation qualities reflected in the scope of its accreditation, such as intra-laboratory intercomparison exercises. In this case, repeat quarterly by two different operators both the calibration of an ionization chamber irradiation of a direct reading personal dosimeter.

  11. Does Obesity Modify the Ability of Prebiopsy Prostate Specific Antigen to Detect Prostate Cancer on Repeat Biopsy? Results from the REDUCE Study.

    Science.gov (United States)

    Vidal, Adriana C; Howard, Lauren E; Moreira, Daniel M; Castro-Santamaria, Ramiro; Andriole, Gerald L; Freedland, Stephen J

    2015-07-01

    Higher body mass index is linked to lower prostate specific antigen. This has given rise to concerns that prostate specific antigen may be less reliable for predicting prostate cancer among obese men. We tested the accuracy of prebiopsy prostate specific antigen for predicting prostate cancer across body mass index categories. We used the REDUCE study, which tested dutasteride for prostate cancer risk reduction in men with a prostate specific antigen of 2.5 to 10.0 ng/ml and a negative pre-study biopsy. All men were required to have a biopsy at 2 and 4 years independent of prostate specific antigen. We assessed the performance of prebiopsy prostate specific antigen to predict overall and high grade prostate cancer (Gleason sum 7 or greater) in each body mass index group using AUC. Of 6,103 men who had a 2-year biopsy 1,646 (27%) were normal weight, 3,209 (53%) were overweight and 1,248 (20%) were obese. Mean adjusted prostate specific antigen for normal weight, overweight and obese subjects on placebo was 7.73, 7.17 and 6.79 ng/ml (p-trend=0.192), and on dutasteride 3.16, 2.93 and 2.62 ng/ml (p=0.008). AUC analysis using raw prostate specific antigen data for predicting prostate cancer ranged from 0.60 to 0.64 in the placebo arm and 0.58 to 0.66 in the dutasteride arm with no difference across body mass index categories (p-interactions ≥0.212). Similar results were found for high grade prostate cancer with AUC ranging from 0.69 to 0.70 in the placebo arm and 0.65 to 0.75 in the dutasteride arm but no differences across body mass index categories (p-interactions ≥0.157). Among men with a previous negative biopsy the accuracy of prebiopsy prostate specific antigen to predict overall and high grade prostate cancer was independent of body mass index. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  12. Disaggregating measurement uncertainty from population variability and Bayesian treatment of uncensored results.

    Science.gov (United States)

    Strom, Daniel J; Joyce, Kevin E; MacLellan, Jay A; Watson, David J; Lynch, Timothy P; Antonio, Cheryl L; Birchall, Alan; Anderson, Kevin K; Zharov, Peter A

    2012-04-01

    In making low-level radioactivity measurements of populations, it is commonly observed that a substantial portion of net results is negative. Furthermore, the observed variance of the measurement results arises from a combination of measurement uncertainty and population variability. This paper presents a method for disaggregating measurement uncertainty from population variability to produce a probability density function (PDF) of possibly true results. To do this, simple, justifiable and reasonable assumptions are made about the relationship of the measurements to the measurands (the 'true values'). The measurements are assumed to be unbiased, that is, that their average value is the average of the measurands. Using traditional estimates of each measurement's uncertainty, a likelihood PDF for each individual's measurand is produced. Then using the same assumptions and all the data from the population of individuals, a prior PDF of measurands for the population is produced. The prior PDF is non-negative, and the average is equal to the average of the measurement results for the population. Using Bayes's theorem, posterior PDFs of each individual measurand are calculated. The uncertainty in these bayesian posterior PDFs appears to be all Berkson with no remaining classical component. The method is applied to baseline bioassay data from the Hanford site. The data include (90)Sr urinalysis measurements of 128 people, (137)Cs in vivo measurements of 5337 people and (239)Pu urinalysis measurements of 3270 people. The method produces excellent results for the (90)Sr and (137)Cs measurements, since there are non-zero concentrations of these global fallout radionuclides in people who have not been occupationally exposed. The method does not work for the (239)Pu measurements in non-occupationally exposed people because the population average is essentially zero relative to the sensitivity of the measurement technique. The method is shown to give results similar to

  13. Results of 194 Double Stars Measurements from Astrometric CCD Observations at the Nikolaev Observatory (Ukraine)

    Science.gov (United States)

    Bodryagin, Daniil; Bondarchuk, Larisa; Maigurova, Nadiia

    2016-04-01

    This paper presents the results of double stars measurements from CCD observations at the 50-cm telescope of the Nikolaev Observatory. The accurate positions at current epoch and proper motions were obtained for 194 WDS pairs. The position angles and separations were measured using REDUC software. The measures standard errors were 0.05" for separations and 0.2° for position angles.

  14. How to statistically analyze nano exposure measurement results: Using an ARIMA time series approach

    NARCIS (Netherlands)

    Klein Entink, R.H.; Fransman, W.; Brouwer, D.H.

    2011-01-01

    Measurement strategies for exposure to nano-sized particles differ from traditional integrated sampling methods for exposure assessment by the use of real-time instruments. The resulting measurement series is a time series, where typically the sequential measurements are not independent from each ot

  15. Results of error correction techniques applied on two high accuracy coordinate measuring machines

    Energy Technology Data Exchange (ETDEWEB)

    Pace, C.; Doiron, T.; Stieren, D.; Borchardt, B.; Veale, R. (Sandia National Labs., Albuquerque, NM (USA); National Inst. of Standards and Technology, Gaithersburg, MD (USA))

    1990-01-01

    The Primary Standards Laboratory at Sandia National Laboratories (SNL) and the Precision Engineering Division at the National Institute of Standards and Technology (NIST) are in the process of implementing software error correction on two nearly identical high-accuracy coordinate measuring machines (CMMs). Both machines are Moore Special Tool Company M-48 CMMs which are fitted with laser positioning transducers. Although both machines were manufactured to high tolerance levels, the overall volumetric accuracy was insufficient for calibrating standards to the levels both laboratories require. The error mapping procedure was developed at NIST in the mid 1970's on an earlier but similar model. The error mapping procedure was originally very complicated and did not make any assumptions about the rigidness of the machine as it moved, each of the possible error motions was measured at each point of the error map independently. A simpler mapping procedure was developed during the early 1980's which assumed rigid body motion of the machine. This method has been used to calibrate lower accuracy machines with a high degree of success and similar software correction schemes have been implemented by many CMM manufacturers. The rigid body model has not yet been used on highly repeatable CMMs such as the M48. In this report we present early mapping data for the two M48 CMMs. The SNL CMM was manufactured in 1985 and has been in service for approximately four years, whereas the NIST CMM was delivered in early 1989. 4 refs., 5 figs.

  16. Results of the round robin exercise on IV-measurements of classic Si-solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Van der Borg, N.J.C.M. [ECN Solar Energy, Petten (Netherlands)

    2012-12-15

    A round robin exercise was performed on IV measurements and spectral response measurements of solar cells. Seven partners participated in the exercise. The aim of the round robin was to enable the verification of their measurement facilities and procedures for IV-measurements on 'classic' Si-solar cells by comparing their measurement data with the other participants. In this way possible flaws in the equipment or procedures can be found and corrected for or the measurement uncertainties can be reassessed. The differences between the measurement results of the various partners were more or less within the expected measurement uncertainty although one or more partners may decide to use the results to reexamine their facilities or procedures.

  17. Analysis of detailed aerodynamic field measurements using results from an aeroelastic code

    Energy Technology Data Exchange (ETDEWEB)

    Schepers, J.G. [Energy Research Centre, Petten (Netherlands); Feigl, L. [Ecotecnia S. coop.c.l. (Spain); Rooij, R. van; Bruining, A. [Delft Univ. of Technology (Netherlands)

    2004-07-01

    In this article an analysis is given of aerodynamic field measurements on wind turbine blades. The analysis starts with a consistency check on the measurements, by relating the measured local aerodynamic segment forces to the overall rotor loads. It is found that the results are very consistent. Moreover, a comparison is made between measured results and results calculated from an aeroelastic code. On the basis of this comparison, the aerodynamic modelling in the aeroelastic code could be improved. This holds in particular for the modelling of 3D stall effects, not only on the lift but also on the drag, and for the modelling of tip effects (author)

  18. Management-by-Results and Performance Measurement in Universities--Implications for Work Motivation

    Science.gov (United States)

    Kallio, Kirsi-Mari; Kallio, Tomi J.

    2014-01-01

    The article focuses on the effects of management-by-results from the perspective of the work motivation of university employees. The study is based on extensive survey data among employees at Finnish universities. According to the results, performance measurement is based on quantitative rather than qualitative measures, and the current…

  19. 48 CFR 1511.011-80 - Data standards for the transmission of laboratory measurement results.

    Science.gov (United States)

    2010-10-01

    ... standards for the transmission of laboratory measurement results. The contracting officer shall insert the... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Data standards for the transmission of laboratory measurement results. 1511.011-80 Section 1511.011-80 Federal Acquisition...

  20. Management-by-Results and Performance Measurement in Universities--Implications for Work Motivation

    Science.gov (United States)

    Kallio, Kirsi-Mari; Kallio, Tomi J.

    2014-01-01

    The article focuses on the effects of management-by-results from the perspective of the work motivation of university employees. The study is based on extensive survey data among employees at Finnish universities. According to the results, performance measurement is based on quantitative rather than qualitative measures, and the current…

  1. Measurements with the heaviest nuclei and further interesting new results; Messungen mit den schwersten Kernen und weitere interessante neue Resultate

    Energy Technology Data Exchange (ETDEWEB)

    Lapidus, Kirill [Physik-Department E12, Technische Universitaet Muenchen, James-Franck-Str. 1, 85748 Garching (Germany); Exzellenzcluster Universe, Boltzmannstr. 2, 85748 Garching (Germany); Collaboration: HADES-Collaboration

    2015-07-01

    HADES is a fixed-target experiment located at the GSI Helmholtzzentrum fuer Schwerionenforschung and operating at the SIS18 accelerator in the range of beam energies of 1-2 GeV/u for nucleus-nucleus collisions, up to 3.5 GeV in proton-induced reactions. HADES explores properties of the strongly-interacting matter in the regime of high baryonic densities and moderate temperatures, as probed in heavy ion reactions. Besides, proton- and pion-nucleus collisions are studied in order to quantify the effects of cold nuclear matter. Two pillars of the HADES physics programme are di-electron and strangeness measurements. The talk will be devoted to the fresh results harvested by HADES in the recent years. A heavy-ion run with Au+Au collisions at 1.23 GeV/u has been accomplished in 2012 and a number of interesting analyses both in the dilepton and in strange sectors will be discussed. In 2014 HADES measured particles produced in pion-induced reactions, employing light (carbon, polyethylene) and heavy (tungsten) nuclear targets. Of special interest here is the in-medium behaviour of strange hadrons and the physics of nucleon resonances. First results from this beam time are presented as well.

  2. METHODS OF MEASURING THE EFFECTS OF LIGHTNING BY SIMULATING ITS STRIKES WITH THE INTERVAL ASSESSMENT OF THE RESULTS OF MEASUREMENTS

    Directory of Open Access Journals (Sweden)

    P. V. Kriksin

    2017-01-01

    Full Text Available The article presents the results of the development of new methods aimed at more accurate interval estimate of the experimental values of voltages on grounding devices of substations and circuits in the control cables, that occur when lightning strikes to lightning rods; the abovementioned estimate made it possible to increase the accuracy of the results of the study of lightning noise by 28 %. A more accurate value of interval estimation were achieved by developing a measurement model that takes into account, along with the measured values, different measurement errors and includes the special processing of the measurement results. As a result, the interval of finding the true value of the sought voltage is determined with an accuracy of 95 %. The methods can be applied to the IK-1 and IKP-1 measurement complexes, consisting in the aperiodic pulse generator, the generator of high-frequency pulses and selective voltmeters, respectively. To evaluate the effectiveness of the developed methods series of experimental voltage assessments of grounding devices of ten active high-voltage substation have been fulfilled in accordance with the developed methods and traditional techniques. The evaluation results confirmed the possibility of finding the true values of voltage over a wide range, that ought to be considered in the process of technical diagnostics of lightning protection of substations when the analysis of the measurement results and the development of measures to reduce the effects of lightning are being fulfilled. Also, a comparative analysis of the results of measurements made in accordance with the developed methods and traditional techniques has demonstrated that the true value of the sought voltage may exceed the measured value at an average of 28 %, that ought to be considered in the further analysis of the parameters of lightning protection at the facility and in the development of corrective actions. The developed methods have been

  3. Verificação da prótese auditiva realizada face a face e via teleconsulta: medidas repetidas Telecounselling and face to face hearing aid verification: repeated measures

    Directory of Open Access Journals (Sweden)

    Deborah Viviane Ferrari

    2012-12-01

    Full Text Available OBJETIVO: avaliar as medidas repetidas da resposta de ressonância da orelha externa sem (REUR e com uso de amplificação (REAR e o ganho de inserção (REIG, realizados face a face e via teleconsulta. MÉTODO: estudo prospectivo longitudinal. Foram realizadas quatro repetições da REUR, REAR e REIG (com estímulo speech noise apresentado em 65 dB NPS e 0º azimute em 19 orelhas de adultos ouvintes normais, via face a face (F e teleconsulta síncrona por controle remoto de aplicativo (T e vídeo interativo. O software Polycom PVX foi utilizado para compartilhamento e transmissão de áudio e vídeo. A conexão foi realizada via LAN (Local Area Network USP na velocidade de 384 kbps Foi calculado o erro causal (Dalhberg entre as quatro medidas para frequências de 250 a 8000 Hz. RESULTADOS: os erros casuais entre as medidas F e T foram muito semelhantes, sendo maiores nas frequências acima de 4 kHz. As diferenças e variações entre as medidas F e T estavam dentro da magnitude de variabilidade do procedimento de medidas com microfone sonda. CONCLUSÃO: as medidas com microfone sonda via teleconsulta fornece resultados confiáveis e similares aos obtidos pelo procedimento padrão.PURPOSE: to evaluate the repeated measurements of the real ear unaided response (REUR, real ear aided response (REAR and insertion gain (REIG conducted as face to face (F and via telecounselling (T. METHOD: longitudinal prospective study. Four measures of REUR, REAR and REIG (carried out with speech noise stimulus presented at 65 dB SPL at 0° azimuth were obtained in 19 ears in normal hearing adults, face to face and via synchronous telecounsellings with remote control of the real ear equipment and interactive video. Polycom PVX software was used for desktop sharing and video and audio transmission. The Loca Area Network (LAN USP was used for the connection (transmission rate: 384 kbps. Dahlberg’s casual errors were calculated for obtaining the measures for

  4. Optimal and safe treatment of spider leg veins measuring less than 1.5 mm on skin type IV patients, using repeated low-fluence Nd:YAG laser pulses after polidocanol injection.

    Science.gov (United States)

    Moreno-Moraga, Javier; Hernández, Esteban; Royo, Josefina; Alcolea, Justo; Isarría, M Jose; Pascu, Mihail Lucian; Smarandache, Adriana; Trelles, Mario

    2013-05-01

    Treatment of micro-veins of less than 1.5 mm with laser and with chemical sclerosis is technically challenging because of their difficulty to remedy. Laser treatment is even more difficult when dark phototypes are involved.Three groups of 30 patients each, skin type IV, and vessels measuring less than 1.5 mm in diameter, were enrolled for two treatment sessions 8 weeks apart: group A, polidocanol (POL) micro-foam injection; group B, Nd:YAG laser alone; and group C, laser after POL injection. Repeated 8-Hz low-fluence pulses, moving the hand piece over a 3-cm vein segment with an average of five laser passes maximum and with a total time irradiation of 1 s were used. Sixteen weeks after the second treatment, statistically, degree of clearance after examining photographs and patients satisfaction index, plotted on a visual analogue scale and comparing results of all three groups, results were significantly better for group C (p<0.0001). No significant differences in complications were noticed between the three groups. Efficacy of combining POL and laser proved safe and satisfactory in 96 % of patients using low-fluence laser pulses with a total cumulative energy in the 3 cm venous segment, lower than that of conventional treatment. Very few and transient complications were observed. POL foam injection followed by laser pulses is safe and efficient for vein treatment in dark-skinned patients.

  5. Real-ear measurements in conductive hearing loss: discrepancies between probe-tube microphone measurements and sound field test results.

    Science.gov (United States)

    Cleaver, V C

    1998-06-01

    This study was designed to investigate earlier observations that probe-tube microphone measurements of insertion gain overestimates the functional gain received from hearing aids by users with significant conductive hearing losses. This was originally thought to be due to artefacts in the probe-tube measurement caused by middle ear pathology, but is now believed to be the result of the bone conduction stimulation of the ear exposed to high intensities of airborne sound during sound field threshold measurements. Since the functional gain must relate to the true aided benefit in such cases, these findings suggest that probe-tube microphone measurements in ears with significant air-bone gaps should be interpreted with caution.

  6. Quality control during repeated fryings

    Directory of Open Access Journals (Sweden)

    Cuesta, C.

    1998-08-01

    Full Text Available Most of the debate ¡s about how the slow or frequent turnover of fresh fat affects the deterioration, of fat used in frying. Then, the modification of different oils used in repeated fryings of potatoes without or with turnover of fresh oil, under similar frying conditions, was evaluated by two criteria: by measuring the total polar component isolated by column chromatography and by the evaluation of the specific compounds related to thermoxidative and hydrolytic alteration by High Performance Size Exclusion Chromatography (HPSEC. The results indicate that with frequent turnover of fresh oil, the critical level of 25% of polar material is rarely reached, and there are fewer problems with fat deterioration because the frying tended to increase the level of polar material and thermoxidative compounds (polymers and dimers of triglycerides and oxidized triglycerides in the fryer oil during the first fryings, followed by minor changes and a tendency to reach a near-steady state in successive fryings. However, in repeated frying of potatoes using a null turnover the alteration rate was higher being linear the relationship found between polar material or the different thermoxidative compounds and the number of fryings. On the other hand chemical reactions produced during deep-fat frying can be minimized by using proper oils. In addition the increased level of consumers awareness toward fat composition and its impact on human health could had an impact on the selection of fats for snacks and for industry. In this way monoenic fats are the most adequate from a nutritional point of view and for its oxidative stability during frying.

  7. Associations between inverted repeats and the structural evolution of bacterial genomes.

    Science.gov (United States)

    Achaz, Guillaume; Coissac, Eric; Netter, Pierre; Rocha, Eduardo P C

    2003-08-01

    The stability of the structure of bacterial genomes is challenged by recombination events. Since major rearrangements (i.e., inversions) are thought to frequently operate by homologous recombination between inverted repeats, we analyzed the presence and distribution of such repeats in bacterial genomes and their relation to the conservation of chromosomal structure. First, we show that there is a strong under-representation of inverted repeats, relative to direct repeats, in most chromosomes, especially among the ones regarded as most stable. Second, we show that the avoidance of repeats is frequently associated with the stability of the genomes. Closely related genomes reported to differ in terms of stability are also found to differ in the number of inverted repeats. Third, when using replication strand bias as a proxy for genome stability, we find a significant negative correlation between this strand bias and the abundance of inverted repeats. Fourth, when measuring the recombining potential of inverted repeats and their eventual impact on different features of the chromosomal structure, we observe a tendency of repeats to be located in the chromosome in such a way that rearrangements produce a smaller strand switch and smaller asymmetries than expected by chance. Finally, we discuss the limitations of our analysis and the influence of factors such as the nature of repeats, e.g., transposases, or the differences in the recombination machinery among bacteria. These results shed light on the challenges imposed on the genome structure by the presence of inverted repeats.

  8. Recent results on the Greenland Aquifer from remote sensing and in situ measurements

    Science.gov (United States)

    Forster, R. R.; Miller, J. Z.; Miège, C.; Brucker, L.; Koenig, L.; Solomon, D. K.; Schmerr, N. C.; Burgess, E. W.; Box, J.

    2014-12-01

    The accelerating loss of mass from the Greenland ice sheet is a major contribution to current sea level rise (SLR) with increased meltwater runoff responsible for half of this mass loss increase, yet the mechanisms and timescales involved in allowing surface meltwater to reach the ocean are poorly understood. The recent discovery of an extensive liquid water reservoir within the Greenland ice sheet firn further complicates the relationship of melt to SLR, since the aquifer system may be either buffering or accelerating SLR. However, even the most fundamental questions about the firn aquifer remain unanswered. A suite of remote sensing data sets coupled with in situ measurements and modeling are used to further constrain the spatial and temporal extent of the Greenland firn aquifer. NASA's Operation IceBridge Accumulation Radar from 2011-2014 are used to map the extent over a majority of the suspected areas. Repeated flight lines are used for multi-temporal analysis which generally indicates stable water depths, however, some changes in extent are detected. We have also tested a variety of ground based radar frequencies for detection of the top and bottom interfaces of the aquifer. Mapping of the retention of liquid water in the firn from space is demonstrated using an active microwave satellite scatterometer (ASCAT). This data set provides near daily observations of the aquifer recharge and freeze process at and below the surface over an integrated penetration depth. One full year of bore hole temperature measurements reveal progression of the aquifer recharge and refreezing from the surface. This provides insight into the thermodynamics and for comparison with satellite data to constrain the ASCAT observable depth of liquid water.

  9. Exploring the Effectiveness of a Measurement Error Tutorial in Helping Teachers Understand Score Report Results

    Science.gov (United States)

    Zapata-Rivera, Diego; Zwick, Rebecca; Vezzu, Margaret

    2016-01-01

    The goal of this study was to explore the effectiveness of a short web-based tutorial in helping teachers to better understand the portrayal of measurement error in test score reports. The short video tutorial included both verbal and graphical representations of measurement error. Results showed a significant difference in comprehension scores…

  10. Exploring the Effectiveness of a Measurement Error Tutorial in Helping Teachers Understand Score Report Results

    Science.gov (United States)

    Zapata-Rivera, Diego; Zwick, Rebecca; Vezzu, Margaret

    2016-01-01

    The goal of this study was to explore the effectiveness of a short web-based tutorial in helping teachers to better understand the portrayal of measurement error in test score reports. The short video tutorial included both verbal and graphical representations of measurement error. Results showed a significant difference in comprehension scores…

  11. 40 CFR 761.316 - Interpreting PCB concentration measurements resulting from this sampling scheme.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Interpreting PCB concentration... § 761.79(b)(3) § 761.316 Interpreting PCB concentration measurements resulting from this sampling... concentration measured in that sample. If the sample surface concentration is not equal to or lower than the...

  12. Five year results of an international proficiency testing programme for measurement of antifungal drug concentrations

    NARCIS (Netherlands)

    Lempers, V.J.C.; Alffenaar, J.W.C.; Touw, D.J.; Burger, D.M.; Uges, D.R.A.; Aarnoutse, R.E.; Brüggemann, R.J.M.

    2014-01-01

    OBJECTIVES: Since 2007 the Dutch Association for Quality Assessment in Therapeutic Drug Monitoring (KKGT) has organized an international interlaboratory proficiency testing (PT) programme for measurement of antifungal drugs in plasma. We describe the 5 year results of the laboratories' performance.

  13. Results of aperture area comparisons for exo-atmospheric total solar irradiance measurements.

    Science.gov (United States)

    Johnson, B Carol; Litorja, Maritoni; Fowler, Joel B; Shirley, Eric L; Barnes, Robert A; Butler, James J

    2013-11-20

    Exo-atmospheric solar irradiance measurements made by the solar irradiance community since 1978 have incorporated limiting apertures with diameters measured by a number of metrology laboratories using a variety of techniques. Knowledge of the aperture area is a critical component in the conversion of radiant flux measurements to solar irradiance. A National Aeronautics and Space Administration (NASA) Earth Observing System (EOS) sponsored international comparison of aperture area measurements of limiting apertures provided by solar irradiance researchers was performed, the effort being executed by the National Institute of Standards and Technology (NIST) in coordination with the EOS Project Science Office. Apertures that had institutional heritage with historical solar irradiance measurements were measured using the absolute aperture measurement facility at NIST. The measurement technique employed noncontact video microscopy using high-accuracy translation stages. We have quantified the differences between the participating institutions' aperture area measurements and find no evidence to support the hypothesis that preflight aperture area measurements were the root cause of discrepancies in long-term total solar irradiance satellite measurements. Another result is the assessment of uncertainties assigned to methods used by participants. We find that uncertainties assigned to a participant's values may be underestimated.

  14. Demonstrating Tools and Results of a Measurement Campaign for Indoor GPS Positioning

    DEFF Research Database (Denmark)

    Kjærgaard, Mikkel Baun; Blunck, Henrik; Godsk, Torben;

    It has been considered a fact that GPS performs too poorly inside buildings to provide usable indoor positioning. We demo raw measurements and results from a measurement campaign which show that using state-of-the-art receivers GPS availability is good in many buildings with standard material walls...... satellite constellation geometry. A comprehensive analysis of the measurement campaign appears as full paper in Pervasive 2010, titled Indoor Positioning Using GPS Revisited. In this demonstration we present the campaign analysis results with an emphasis on visualization and animation. Another focus...

  15. Results after first year of automated wind measurements in Santa Cruz, southern Patagonia

    Energy Technology Data Exchange (ETDEWEB)

    Oliva, R.B. [Universidad Nacional de la Patagonia Austral, Centro de Investigacion, Rio Gallegos (Argentina)

    1997-12-31

    The first year of automated measurements of wind intensity and direction in the campus site of the UNPA in Rio Gallegos, Argentina, produces interesting results and could be of benefit as an experimental background for the assessment of the economic potential of wind energy in local areas. The results show the strong stational variations of wind, with extreme intensities in summer and long periods of calm in winter. Also clear are the main directions of wind, with W-SW predominant. Measurements were taken with a calibrated pulse anemometer (NRG 40HC) and an analog output wind vane (NRG 100P), mounted on a 10m high steel tubular tower, coupled to a laboratory data logger with programmable configuration. The measurements compared successfully with results from other commercial measurement systems mounted in the area in the meantime. (author)

  16. Revisiting the TALE repeat.

    Science.gov (United States)

    Deng, Dong; Yan, Chuangye; Wu, Jianping; Pan, Xiaojing; Yan, Nieng

    2014-04-01

    Transcription activator-like (TAL) effectors specifically bind to double stranded (ds) DNA through a central domain of tandem repeats. Each TAL effector (TALE) repeat comprises 33-35 amino acids and recognizes one specific DNA base through a highly variable residue at a fixed position in the repeat. Structural studies have revealed the molecular basis of DNA recognition by TALE repeats. Examination of the overall structure reveals that the basic building block of TALE protein, namely a helical hairpin, is one-helix shifted from the previously defined TALE motif. Here we wish to suggest a structure-based re-demarcation of the TALE repeat which starts with the residues that bind to the DNA backbone phosphate and concludes with the base-recognition hyper-variable residue. This new numbering system is consistent with the α-solenoid superfamily to which TALE belongs, and reflects the structural integrity of TAL effectors. In addition, it confers integral number of TALE repeats that matches the number of bound DNA bases. We then present fifteen crystal structures of engineered dHax3 variants in complex with target DNA molecules, which elucidate the structural basis for the recognition of bases adenine (A) and guanine (G) by reported or uncharacterized TALE codes. Finally, we analyzed the sequence-structure correlation of the amino acid residues within a TALE repeat. The structural analyses reported here may advance the mechanistic understanding of TALE proteins and facilitate the design of TALEN with improved affinity and specificity.

  17. Dynamics of Graft Function Measured by DNA-Technology in a Patient with Severe Aplastic Anemia and Repeated Stem Cell Transplantation

    Directory of Open Access Journals (Sweden)

    Anna Karastaneva

    2014-01-01

    Full Text Available Although bone marrow transplantation (BMT from an HLA identical sibling is considered as treatment of choice in pediatric patients with severe aplastic anemia (SAA, a significant number of them experience graft failure (GF after BMT. We report a case of an 8-year-old male patient with SAA who presented with a complicated posttransplant course due to parvovirus B19 infection and GF. A subsequent attempt to support the graft by antithymocyte globulin (ATG and a peripheral stem cell boost resulted in transitory autologous recovery of hematopoiesis followed by mixed chimerism, supported by donor lymphocyte infusions (DLIs and finally graft rejection with relapse of SAA. Permanent complete chimerism was achieved by a second BMT. Dynamics of graft function, measured by a single nucleotide polymorphism (SNPs analysis, are discussed.

  18. 重复测试和不同性别对小鼠旷场行为的影响%Repeated Measurement and Sex for the Behavior in Open Field in Mice

    Institute of Scientific and Technical Information of China (English)

    陈超杰; 钟志凤; 俞昌喜

    2014-01-01

    OBJECTIVE To study the effect on the locomotory activity and anxiety-like behavior of laboratory mice by both factors of repeated measurement and sex.METHODS The total distance traveled ,total mean velocity , total parallel index,the percentage of distance in center zone ,the mean velocity in center zone ,the center zone en-tries,the percentage of time spent in center zone and the parallel index in center zone of the female and male mice for 5 minutes were recorded and analyzed in open field test by animal video tracking analysis system ,once a day for 3 days.RESULTS In the open field test ,the indexes of the total distance traveled ,total mean velocity ,total parallel index ,the percentage of distance in center zone ,the mean velocity in center zone ,the center zone entries ,the percent-age of time spent in center zone and the parallel index in center zone in mice showed the downtrend as the measure -ment numbers were increasing ( P0.05 ).However ,as repeating the tests ,the downtrend of these in male mice were seemly more significant than female mice ,especially in the third time measurement ,in which the mean velocity ( P<0.05 ) and parallel index ( P<0.01 ) in center zone were lower than the ones in female mice ,respectively.CONCLUSION The repeated measurement inferences the locomotory activity and interrupted the anxiety state of mice.Sex of mice does not make the behavior in open field different at the first time ,but the repeated measurement seemly more signifi-cantly affect the locomotory activity of the male mice than the female.%目的:研究重复测试和不同性别两个因素对小鼠在旷场试验中自主行为活动和焦虑行为的影响。方法通过动物视频行为分析系统,分别记录和分析雌雄小鼠5 min内在旷场中的总路程、总体平均速度、总体平行指数、中央区的路程占总路程的比例、中央区的平均速度、中央区进入次数、中央区停留时间占整体测试时间的比例和中

  19. EAMJ Dec. Repeatability.indd

    African Journals Online (AJOL)

    2008-12-12

    Dec 12, 2008 ... Results:Kappa values for four-week repeatability for the wheeze and asthma questions were 0.61 ... for logistic, cultural and ethical reasons, to use ... individual with baseline forced expiratory volume in .... period is likely to also include the effects of true ... data, the writing of the manuscript or the decision.

  20. A Repeating Fast Radio Burst

    CERN Document Server

    Spitler, L G; Hessels, J W T; Bogdanov, S; Brazier, A; Camilo, F; Chatterjee, S; Cordes, J M; Crawford, F; Deneva, J; Ferdman, R D; Freire, P C C; Kaspi, V M; Lazarus, P; Lynch, R; Madsen, E C; McLaughlin, M A; Patel, C; Ransom, S M; Seymour, A; Stairs, I H; Stappers, B W; van Leeuwen, J; Zhu, W W

    2016-01-01

    Fast Radio Bursts are millisecond-duration astronomical radio pulses of unknown physical origin that appear to come from extragalactic distances. Previous follow-up observations have failed to find additional bursts at the same dispersion measures (i.e. integrated column density of free electrons between source and telescope) and sky position as the original detections. The apparent non-repeating nature of the fast radio bursts has led several authors to hypothesise that they originate in cataclysmic astrophysical events. Here we report the detection of ten additional bursts from the direction of FRB121102, using the 305-m Arecibo telescope. These new bursts have dispersion measures and sky positions consistent with the original burst. This unambiguously identifies FRB121102 as repeating and demonstrates that its source survives the energetic events that cause the bursts. Additionally, the bursts from FRB121102 show a wide range of spectral shapes that appear to be predominantly intrinsic to the source and wh...

  1. Understanding the subsurface thermal structure of deep sedimentary basins in Denmark - measurements and modelling results

    DEFF Research Database (Denmark)

    Balling, N.; Poulsen, Søren Erbs; Bording, Thue Sylvester

    2015-01-01

    equilibrium temperature logging has been carried out in a number of accessible deep boreholes. A regional distribution of subsurface temperatures is obtained by combining measurements and 3D numerical modelling in which the heat equation is solved. Modelling results are constrained by observations in terms....... Information of subsurface temperature distribution originates from direct measurements in boreholes and from indirect theoretical modelling. "Point observations" of varying quality are available as industrially measured "Bottom Hole Temperatures" from deep exploration boreholes and accurate continuous...... of available measured temperatures and observed surface heat flow. Information on subsurface thermal conductivity, which is a critical parameter, is obtained from core measurements and well-log analyses. Interval temperature gradients are found to vary by a factor of three to four across lithologies...

  2. Analysis of Factors Influencing Measurement Accuracy of Al Alloy Tensile Test Results

    Science.gov (United States)

    Podgornik, Bojan; Žužek, Borut; Sedlaček, Marko; Kevorkijan, Varužan; Hostej, Boris

    2016-02-01

    In order to properly use materials in design, a complete understanding of and information on their mechanical properties, such as yield and ultimate tensile strength must be obtained. Furthermore, as the design of automotive parts is constantly pushed toward higher limits, excessive measuring uncertainty can lead to unexpected premature failure of the component, thus requiring reliable determination of material properties with low uncertainty. The aim of the present work was to evaluate the effect of different metrology factors, including the number of tested samples, specimens machining and surface quality, specimens input diameter, type of testing and human error on the tensile test results and measurement uncertainty when performed on 2xxx series Al alloy. Results show that the most significant contribution to measurement uncertainty comes from the number of samples tested, which can even exceed 1 %. Furthermore, moving from experimental laboratory conditions to very intense industrial environment further amplifies measurement uncertainty, where even if using automated systems human error cannot be neglected.

  3. Air pollution from residential wood combustion in a Danish village. Measuring campaign and analysis of results

    Energy Technology Data Exchange (ETDEWEB)

    Waahlin, P.; Roerdam Olesen, H.; Bossi, R.; Stubkjaer, J.

    2010-05-15

    A campaign took place in the winter 2006/2007 comprising measurements of many air pollution components at two sites: a wood smoke exposed site within the village Slagslunde, and a background site 500 m outside of the village. The report describes the campaign and its results. A central result is a so-called 'wood smoke source profile', which relates several measures of wood smoke pollution to each other. This is based on a 'cleaned' data set, for which the effect of other sources than wood smoke was small. The wood smoke profile links the measures PM2.5, particle volume, soot, monosaccharide anhydrides (levoglucosan and mannosan) and different PAHs to each other. Particle number N does not have a close link to the other measures. (author)

  4. Initial Results of Aperture Area Comparisons for Exo-Atmospheric Total Solar Irradiance Measurements

    Science.gov (United States)

    Johnson, B. Carol; Litorja, Maritoni; Fowler, Joel B.; Butler, James J.

    2009-01-01

    In the measurement of exo-atmospheric total solar irradiance (TSI), instrument aperture area is a critical component in converting solar radiant flux to irradiance. In a May 2000 calibration workshop for the Total Irradiance Monitor (TIM) on the Earth Observing System (EOS) Solar Radiation and Climate Experiment (SORCE), the solar irradiance measurement community recommended that NASA and NISI coordinate an aperture area measurement comparison to quantify and validate aperture area uncertainties and their overall effect on TSI uncertainties. From May 2003 to February 2006, apertures from 4 institutions with links to the historical TSI database were measured by NIST and the results were compared to the aperture area determined by each institution. The initial results of these comparisons are presented and preliminary assessments of the participants' uncertainties are discussed.

  5. Long-term aerobic exercise and omega-3 supplementation modulate osteoporosis through inflammatory mechanisms in post-menopausal women: a randomized, repeated measures study

    Directory of Open Access Journals (Sweden)

    Kanaley Jill

    2011-10-01

    Full Text Available Abstract Background Evidence indicates that dietary fats and physical activity influence bone health. The purpose of this study was to examine the effects of long-term aerobic exercise and omega-3 (N-3 supplementation on serum inflammatory markers, bone mineral density (BMD, and bone biomarkers in post-menopausal women. Methods Seventy-nine healthy sedentary post-menopausal women aged 58-78 years participated in this study. Subjects were randomized to one of 4 groups: exercise + supplement (E+S, n = 21, exercise (E, n = 20, supplement (S, n = 20, and control (Con, n = 18 groups. The subjects in the E+S and E groups performed aerobic exercise training (walking and jogging up to 65% of HRmax, three times a week for 24 weeks. Subjects in the E+S and S groups consumed 1000 mg/d N-3 for 24 weeks. The lumbar spine (L2-L4 and femoral neck BMD, serum tumor necrosis factor (TNF α, interleukin (IL 6, prostaglandin (PG E2, estrogen, osteocalcin, 1, 25-dihydroxyvitamin D3 (1, 25 Vit D, C-telopeptide (CTX, parathyroid hormone (PTH and calcitonin (CT were measured at baseline, the end of week 12 and 24. Results Serum estrogen, osteocalcin, 1, 25 Vit D, CT, L2-L4 and femoral neck BMD measures increased (P 2 decreased (P 2-L4 and femoral neck BMD, estrogen, osteocalcin, and CT were negatively (P 2. PTH and CT were correlated positively and negatively with IL-6, respectively (P Conclusions The present study demonstrates that long-term aerobic exercise training plus N-3 supplementation have a synergistic effect in attenuating inflammation and augmenting BMD in post-menopausal osteoporosis.

  6. Recursive quantum repeater networks

    CERN Document Server

    Van Meter, Rodney; Horsman, Clare

    2011-01-01

    Internet-scale quantum repeater networks will be heterogeneous in physical technology, repeater functionality, and management. The classical control necessary to use the network will therefore face similar issues as Internet data transmission. Many scalability and management problems that arose during the development of the Internet might have been solved in a more uniform fashion, improving flexibility and reducing redundant engineering effort. Quantum repeater network development is currently at the stage where we risk similar duplication when separate systems are combined. We propose a unifying framework that can be used with all existing repeater designs. We introduce the notion of a Quantum Recursive Network Architecture, developed from the emerging classical concept of 'recursive networks', extending recursive mechanisms from a focus on data forwarding to a more general distributed computing request framework. Recursion abstracts independent transit networks as single relay nodes, unifies software layer...

  7. Preliminary result of bunch length measurement using a modified Michelson interferometer

    Institute of Scientific and Technical Information of China (English)

    LIN Xu-Ling; ZHANG Jian-Bing; LUO Feng; BEI Hua; LU Shan-Liang; YU Tie-Min; DAI Zhi-Min

    2009-01-01

    Based on the femtosecond accelerator device which was built at the Shanghai Institute of Applied Physics (SINAP), recently a modified far infrared Michelson interferometer has been developed to measure the length of electron bunches via the optical autocorrelation method.Compared with our former normal Michelson interferometer, we use a hollow retroreflector instead of a flat mirror as the reflective mirror.The experimental setup and results of the bunch length measurement will be described in this paper.

  8. Approximation of Measurement Results of “Emergency” Signal Reception Probability

    Directory of Open Access Journals (Sweden)

    Gajda Stanisław

    2017-08-01

    Full Text Available The intended aim of this article is to present approximation results of the exemplary measurements of EMERGENCY signal reception probability. The probability is under-stood as a distance function between the aircraft and a ground-based system under established conditions. The measurements were approximated using the properties of logistic functions. This probability, as a distance function, enables to determine the range of the EMERGENCY signal for a pre-set confidence level.

  9. MEASURING RESULTS NUMERAL TREATMENT OF IMPULSIVE CURRENTS BY MEANS OF ROGOVSKY BELT APPLICATION

    Directory of Open Access Journals (Sweden)

    U. Batygin

    2009-01-01

    Full Text Available The technique of numerical processing of measurement results of pulse currents by means of Rogovsky belt application is offered in the given work. It is shown that at measurement of signals by digital oscillographs and further numerical transformation of target signals, the possibilities of Rogovsky belt without the application of additional devices that in turn allows to define parameters of pulse currents with any peak-time characteristics essentially expand.

  10. An Improved Result for Positive Measure Reducibility of Quasi-periodic Linear Systems

    Institute of Scientific and Technical Information of China (English)

    Hai Long HE; Jian Gong YOU

    2006-01-01

    In this paper, by the KAM method, under weaker small denominator conditions and nondegeneracy conditions, we prove a positive measure reducibility for quasi-periodic linear systems close to constant: X = (A(λ) + F((ψ),λ))X, (ψ)=ω where the parameter λ∈ (a, b), ω is a fixed Diophantine vector, which is a generalization of Jorba & Simó's positive measure reducibility result.

  11. Repeatability of Harris Corner Detector

    Institute of Scientific and Technical Information of China (English)

    HU Lili

    2003-01-01

    Interest point detectors are commonly employed to reduce the amount of data to be processed. The ideal interest point detector would robustly select those features which are most appropriate or salient for the application and data at hand. This paper shows that interest points are geometrically stable under different transformations.This property makes interest points very successful in the context of image matching. To measure this property quantatively, we introduce a evaluation criterion: repeatability rate.

  12. Reward modulation of contextual cueing: Repeated context overshadows repeated target location.

    Science.gov (United States)

    Sharifian, Fariba; Contier, Oliver; Preuschhof, Claudia; Pollmann, Stefan

    2017-08-07

    Contextual cueing can be enhanced by reward. However, there is a debate if reward is associated with the repeated target-distractor configurations or with the repeated target locations that occur in both repeated and new displays. Based on neuroimaging evidence, we hypothesized that reward becomes associated with the target location only in new displays, but not in repeated displays, where the repeated target location is overshadowed by the more salient repeated target-distractor configuration. To test this hypothesis, we varied the reward value associated with the same target location in repeated and new displays. The results confirmed the overshadowing hypothesis in that search facilitation in repeated target-distractor configurations was modulated by the variable value associated with the target location. This effect was observed mainly in early learning.

  13. Relative contributions of interface pressure, shear stress, and temperature on ischemic-induced, skin-reactive hyperemia in healthy volunteers: a repeated measures laboratory study.

    Science.gov (United States)

    Lachenbruch, Charlie; Tzen, Yi-Ting; Brienza, David; Karg, Patricia E; Lachenbruch, Peter A

    2015-02-01

    Although the primary risk factors for pressure ulcer development - pressure, shear, skin temperature, moisture, and friction - have been identified for decades, the relative contribution of each to this risk remains unclear. To confirm the results of and expand upon earlier research into the relative contributions of interface pressures, shear stress, and skin temperature among 4 healthy volunteers, a study involving 6 additional healthy 40- to 75-year-old volunteers was conducted and results of the 2 studies were pooled. All 3 variables (interface pressures, shear stress, and skin temperature) were systematically and randomly varied. In the prone position, volunteers each underwent 18 test conditions representing different combinations of temperature (28˚ C, 32˚ C, 36˚ C), pressure (8.0 and 13.3 kPa), and shear (0, 6.7, and 14.0 kPa) using a computer-controlled indenter applied to the sacrum for 20 minutes exerting weights of 100 g and 200 g to induce 0.98 N and 1.96 N of shear force, respectively. Each condition was tested twice, resulting in a total of 360 trials. Magnitude of postload reactive hyperemia as an index of ischemia was measured by laser Doppler flowmetry. Fixed effects regression models were used to predict 3 different indices of reactive hyperemic magnitude. Friedman tests were performed to compare the reactive hyperemia among 3 different skin temperatures or shear stresses under the same amount of localized pressure. In all regression models, pressure and temperature were highly significant predictors of the extent of reactive hyperemia (P pressure and shear stress, and the difference was more profound between 32˚ C and 36˚ C than between 28˚ C and 32˚ C. These results confirm that, in laboratory settings, temperature is an important factor in tissue ischemia. Additional studies examining the relative importance of pressure, shear, and temperature and potential effects of lowering temperature on tissue ischemia in healthy volunteers and

  14. Measurements on NASA Langley Durable Combustor Rig by TDLAT: Preliminary Results

    Science.gov (United States)

    Busa, Kristin; Ellison, Erik N.; McGovern, Brian J.; McDaniel, James C.; Diskin, Glenn S.; DePiro, Maxwell J.; Capriotti, Diego P.; Gaffney, Richard L.

    2013-01-01

    Detailed knowledge of the internal structure of high-enthalpy flows can provide valuable insight to the performance of scramjet combustors. Tunable Diode Laser Absorption Spectroscopy (TDLAS) is often employed to measure temperature and species concentration. However, TDLAS is a path-integrated line-of-sight (LOS) measurement, and thus does not produce spatially resolved distributions. Tunable Diode Laser Absorption Tomography (TDLAT) is a non-intrusive measurement technique for determining two-dimensional spatially resolved distributions of temperature and species concentration in high enthalpy flows. TDLAT combines TDLAS with tomographic image reconstruction. Several separate line-of-sight TDLAS measurements are analyzed in order to produce highly resolved temperature and species concentration distributions. Measurements have been collected at the University of Virginia's Supersonic Combustion Facility (UVaSCF) as well as at the NASA Langley Direct-Connect Supersonic Combustion Test Facility (DCSCTF). Measurements collected at the DCSCTF required significant modifications to system hardware and software designs due to its larger measurement area and shorter test duration. Initial LOS measurements from the NASA Langley DCSCTF operating at an equivalence ratio of 0.5 are presented. Results show the capability of TDLAT to adapt to several experimental setups and test parameters.

  15. Results of the PEP`93 intercomparison of reference cell calibrations and newer technology performance measurements

    Energy Technology Data Exchange (ETDEWEB)

    Osterwald, C.R.; Emery, K. [National Renewable Energy Lab., Golden, CO (United States); Anevsky, S. [All-Union Research Inst. for Optophysical Measurements, Moscow (Russian Federation)] [and others

    1996-05-01

    This paper presents the results of an international intercomparison of photovoltaic (PV) performance measurements and calibrations. The intercomparison, which was organized and operated by a group of experts representing national laboratories from across the globe (i.e., the authors of this paper), was accomplished by circulating two sample sets. One set consisted of twenty silicon reference cells that would, hopefully, form the basis of an international PV reference scale. A qualification procedure applied to the calibration results gave average calibration numbers with an overall standard deviation of less than 2% for the entire set. The second set was assembled from a wide range of newer technologies that present unique problems for PV measurements. As might be expected, these results showed much larger differences among laboratories. Methods were then identified that should be used to measure such devices, along with problems to avoid.

  16. The comparison of measured impedance of the bladder tissue with the computational modeling results

    Directory of Open Access Journals (Sweden)

    ahmad keshtkar

    2015-11-01

    Full Text Available Introduction: The electrical impedance spectroscopy technique can be used to measure the electrical impedance of the human bladder tissue, for differentiating pathological changes in the urothelium. Methods: In this study, the electrical impedance spectroscopy technique and then, a numerical technique, finite element analysis (FEA were used to model the electrical properties of this tissue to predict the impedance spectrum of the normal and malignant areas of this organ. Results: After determining and comparing the modeled data with the experimental results, it is believed that there are some factors that may affect the measurement results. Thus, the effect of inflammation, edema, changes in the applied pressure over the probe and the distensible property of the bladder tissue were considered. Furthermore, the current distribution inside the human bladder tissue was modeled in normal and malignant cases using the FEA. This model results showed that very little of the current actually flows through the urothelium and much of the injected current flows through the connective tissue beneath the urothelium. Conclusion: The results of the models do not explain the measurements results. In conclusion, there are many factors, which may account for discrepancies between the measured and modeled data.

  17. Relationships between anthropometric measures and athletic performance, with special reference to repeated-sprint ability, in the Qatar national soccer team.

    Science.gov (United States)

    Brocherie, Franck; Girard, Olivier; Forchino, Fabricio; Al Haddad, Hani; Dos Santos, Gilvan A; Millet, Grégoire P

    2014-01-01

    The aim of this study was to determine potential relationships between anthropometric parameters and athletic performance with special consideration to repeated-sprint ability (RSA). Sixteen players of the senior male Qatar national soccer team performed a series of anthropometric and physical tests including countermovement jumps without (CMJ) and with free arms (CMJwA), straight-line 20 m sprint, RSA (6 × 35 m with 10 s recovery) and incremental field test. Significant (P sprinting times and r = 0.54 for maximal sprinting speed) with the exception of the sprint decrement score (Sdec). The sum of six skinfolds and adipose mass index were largely correlated with Sdec (r = 0.68, P 0.05, respectively) or any standard athletic tests. Multiple regression analyses indicated that muscular cross-sectional area for mid-thigh, adipose index, straight-line 20 m time, maximal sprinting speed and CMJwA are the strongest predictors of Sdec (r(2) = 0.89) and TT (r(2) = 0.95) during our RSA test. In the Qatar national soccer team, players' power-related qualities and RSA are associated with a high muscular profile and a low adiposity. This supports the relevance of explosive power for the soccer players and the larger importance of neuromuscular qualities determining the RSA.

  18. Evaluation of repeated measurements of radon-222 concentrations in well water sampled from bedrock aquifers of the Piedmont near Richmond, Virginia, USA: effects of lithology and well characteristics.

    Science.gov (United States)

    Harris, Shelley A; Billmeyer, Ernest R; Robinson, Michael A

    2006-07-01

    Radon (222Rn) concentrations in 26 ground water wells of two distinct lithologies in the Piedmont of Virginia were measured to assess variation in ground water radon concentrations (GWRC), to evaluate differences in concentrations related to well characteristics, lithology, and spatial distributions, and to assess the feasibility of predicting GWRC. Wells were sampled in accordance with American Public Health Association Method 7500 Rn-B, with modifications to include a well shaft profile analysis that determined the minimum purge time sufficient to remove the equivalent of one column of water from each well. Statistically significant differences in GWRC were found in the Trssu (1482 +/- 1711 pCi/L) and Mpg (7750 +/- 5188 pCi/L) lithologies, however, no significant differences were found among GWRC at each well over time. Using multiple regression, 86% of the variability (R2) in the GWRC was explained by the lithology, latitudinal class, and water table elevation of the wells. The GWRC in a majority of the wells studied exceed US Environmental Protection Agency designated maximum contaminant level and AMCL. Results support modifications to sampling procedures and indicate that, in previous studies, variations in GWRC concentrations over time may have been due in part to differences in sampling procedures and not in source water.

  19. Tight Results on Multiregister Fourier Sampling: Quantum Measurements for Graph Isomorphism Require Entanglement

    CERN Document Server

    Moore, Cristopher; Moore, Cristopher; Russell, Alexander

    2005-01-01

    We establish a general method for proving bounds on the information that can be extracted via arbitrary entangled measurements on tensor products of hidden subgroup coset states. When applied to the symmetric group, the method yields an Omega(n log n) lower bound on the number of coset states over which we must perform an entangled measurement in order to obtain non-negligible information about a hidden involution. These results are tight to within a multiplicative constant and apply, in particular, to the case relevant for the Graph Isomorphism problem. Part of our proof was obtained after learning from Hallgren, Roetteler, and Sen that they had obtained similar results.

  20. Indoor Environment and Energy Use in Historic Buildings - Comparing Survey Results with Measurements and Simulations

    DEFF Research Database (Denmark)

    Rohdin, P.; Dalewski, M.; Moshfegh, B.

    2012-01-01

    Increasing demand for energy efficiency places new requirements on energy use in historic buildings. Efficient energy use is essential if a historic building is to be used and preserved, especially buildings with conventional uses such as residential buildings and offices. This paper presents...... results which combine energy auditing with building energy simulation and an indoor environment survey among the occupants of the building. Both when comparing simulations with measurements as well as with survey results good agreement was found. The two efficiency measures that are predicted to increase...... energy and thermal performance the most for this group of buildings were reduced infiltration and increasing heat-exchanger efficiency....

  1. An overview of the measurements of thermophysical properties and some results on molten superalloys and semiconductors

    Science.gov (United States)

    Taylor, R. E.

    1993-01-01

    This presentation consists of two parts: comments on the results of measurements on thermophysical properties based on the paper, 'Things Mother Never Taught Me (About Thermophysical Properties of Solids)' and results of thermophysical property measurements on selected solid and molten semiconductors and a proprietary superalloy. The first part may be considered as a tutorial for those involved in using or procuring thermophysical property data. The second part is presented as illustrations of what has been accomplished on molten materials at the Thermophysical Properties Research Laboratory (TPRL). The materials include Ge, PbTe, PbSnTe, HgCdTe and a superalloy.

  2. Measurement of the electrostatic charge in airborne particles: I - development of the equipment and preliminary results

    Directory of Open Access Journals (Sweden)

    Marra Jr. W.D.

    2000-01-01

    Full Text Available The design and construction of a equipment capable of measuring the electrostatic charges in aerosols, named the electrostatic charge classifier, were carried out. They were based on the concept of particle electromobility and the charge classifier was intended to classify the nature and the distribution of electrostatic charges as a function of particle size. The resulting piece of equipment is easy to dismount, which facilitates its cleaning and transport, and easy to operate. Early results indicate that the values of electrostatic charge measured on test particles are inside the range reported in the literature, indicating the adequacy of the technique utilized.

  3. Perfusion CT measurements in healthy cervical spinal cord: feasibility and repeatability of the study as well as interchangeability of the perfusion estimates using two commercially available software packages

    Energy Technology Data Exchange (ETDEWEB)

    Bisdas, Sotirios [Johann Wolfgang University Hospital, Department of Radiology, Frankfurt (Germany); Medical University of South Carolina, Department of Radiology, Charleston, SC (United States); Johann Wolfgang Goethe University Hospital, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Rumboldt, Zoran; Deveikis, John; Spampinato, Maria Vittoria [Medical University of South Carolina, Department of Radiology, Charleston, SC (United States); Surlan, Katarina [Clinical Centre Ljubljana, Department of Clinical Radiology, Ljubljana (Slovenia); Koh, Tong San [Nanyang Technological University, School of Electrical and Electronic Engineering, Singapore (Singapore)

    2008-10-15

    Our purpose was to examine the feasibility and reproducibility of perfusion CT studies in the cervical spinal cord and the interchangeability of the values obtained by two post-processing methods. The perfusion CT studies of 40 patients with neck tumours were post-processed using two software packages (Software-1: deconvolution-based analysis with adiabatic tissue homogeneity approach and Software-2: maximum-slope-model with Patlak analysis). Eight patients were examined twice for assessing the reproducibility of the technique. Two neuroradiologists separately post-processed the images with two arterial input functions (AIFs): (1) the internal carotid artery (ICA) and (2) the vertebral artery (VA). Maps of blood flow (F) in ml/min/100 g, blood volume (V) in ml/100 g, mean transit time (MTT) in seconds (s) and permeability (PS) in ml/min/100 g were generated. The mean F, V, MTT and PS (Software-1) with VA-AIF and ICA-AIF were 8.93, 1.12, 16.3, 1.88 and 8.57, 1.19, 16.85 and 1.94, respectively. The reproducibility of the techniques was satisfactory, while the V and MTT values (in Software-1) and the F and V values (in Software-2) were dependent on the site of the AIF (p{>=}0.03 and p=0.02, respectively). The interobserver agreement was very good. The significant differences in measurements for a single patient (%) using Software-1/Software-2 were {+-}120%/110%, 90%/80%, 180% and 250%/130% for F, V, MTT and PS, respectively. Only F and PS values in the healthy tissue seemed to be interchangeable. Our results were in essential agreement with those derived by invasive measurements in animals. The cervical spine perfusion CT studies are feasible and reproducible. The present knowledge has to be validated with studies in spinal cord tumours in order to decide the usefulness of the perfusion CT in this field. (orig.)

  4. Preliminary results of spectral induced polarization measurements, Wadi Bidah District, Kingdom of Saudi Arabia

    Science.gov (United States)

    Smith, Bruce D.; Tippens, C.L.; Flanigan, V.J.; Sadek, Hamdy

    1983-01-01

    Laboratory spectral induced polarization (SIP) measurements on 29 carbonaceous schist samples from the Wadi Bidah district show that most are associated with very long polarization decays or, equivalently, large time constants. In contrast, measurements on two massive sulfide samples indicate shorter polarization decays or smaller time constants. This difference in time constants for the polarization process results in two differences in the phase spectra in the frequency range of from 0.06 to 1Hz. First, phase values of carbonaceous rocks generally decrease as a function of increasing frequency. Second, phase values of massive sulfide-bearing rocks increase as a function of increasing frequency. These results from laboratory measurements agree well with those from other reported SIP measurements on graphites and massive sulfides from the Canadian Shield. Four SIP lines, measured by using a 50-m dipole-dipole array, were surveyed at the Rabathan 4 prospect to test how well the results of laboratory sample measurements can be applied to larger scale field measurements. Along one line, located entirely over carbonaceous schists, the phase values decreased as a function of increasing frequency. Along a second line, located over both massive sulfides and carbonaceous schists as defined by drilling, the phase values measured over carbonaceous schists decreased as a function of increasing frequency, whereas those measured over massive sulfides increased. In addition, parts of two lines were surveyed down the axes of the massive sulfide and carbonaceous units. The phase values along these lines showed similar differences between the carbonaceous schists and massive sulfides. To date, the SIP survey and the SIP laboratory measurements have produced the only geophysical data that indicate an electrical difference between the massive sulfide-bearing rocks and the surrounding carbonaceous rocks in the Wadi Bidah district. However, additional sample and field measurements in

  5. Computer-assisted uncertainty assessment of k0-NAA measurement results

    Science.gov (United States)

    Bučar, T.; Smodiš, B.

    2008-10-01

    In quantifying measurement uncertainty of measurement results obtained by the k0-based neutron activation analysis ( k0-NAA), a number of parameters should be considered and appropriately combined in deriving the final budget. To facilitate this process, a program ERON (ERror propagatiON) was developed, which computes uncertainty propagation factors from the relevant formulae and calculates the combined uncertainty. The program calculates uncertainty of the final result—mass fraction of an element in the measured sample—taking into account the relevant neutron flux parameters such as α and f, including their uncertainties. Nuclear parameters and their uncertainties are taken from the IUPAC database (V.P. Kolotov and F. De Corte, Compilation of k0 and related data for NAA). Furthermore, the program allows for uncertainty calculations of the measured parameters needed in k0-NAA: α (determined with either the Cd-ratio or the Cd-covered multi-monitor method), f (using the Cd-ratio or the bare method), Q0 (using the Cd-ratio or internal comparator method) and k0 (using the Cd-ratio, internal comparator or the Cd subtraction method). The results of calculations can be printed or exported to text or MS Excel format for further analysis. Special care was taken to make the calculation engine portable by having possibility of its incorporation into other applications (e.g., DLL and WWW server). Theoretical basis and the program are described in detail, and typical results obtained under real measurement conditions are presented.

  6. [The study on the influence of bovine enamel hardness measurement methods on the result evaluation].

    Science.gov (United States)

    Zhang, Dianyun; Lin, Hong; Zheng, Rui; Han, Jianmin; Zheng, Gang

    2013-02-01

    The variation in hardness of enamel is a frequently used method to evaluate the influence of whiting materials on the enamel. The purpose of this study is to improve the veracity on the evaluation tests caused by the tooth itself with point selection method. Three kinds of testing point selection methods on enamel were carried out, i. e. random selection, grid measurement and symmetrical measurement, respectively. The selected points were used to measure the micro hardness by Vickers. The influence of the variation of tooth structure itself on the hardness measurements results can be reduced by using testing point selection methods of symmetry, and thus, the accuracy of the test method used in the evaluation of the influence of dental materials on tooth hardness will be guaranteed.

  7. Latest results on top production from the CMS and ATLAS collaborations: inclusive and differential measurements

    CERN Document Server

    Tassi, Enrico; The ATLAS collaboration

    2015-01-01

    In proton-proton collisions at the LHC, pairs of top and anti-top quarks are expected to be mostly produced through gluon fusion and the large number of ttbar pairs can be used to test the predictions of Quantum Chromodynamics. Measurements of the top quark production cross sections in proton-proton collisions at 7 and 8 TeV with the ATLAS and CMS detectors at the Large Hadron Collider are presented. Both inclusive and differential cross-section measurements are compared to the theoretical predictions. We also present measurements of the spin correlation between top and anti-top quarks as well as of the top-quark charge asymmetry which constitute important tests of QCD and are sensitive to potential contributions from new physics. Besides being compared to different predictions from the standard model the measurements the results are also used to extract the strong coupling constant and the pole mass.

  8. Preliminary results of an extensive study of fragmentation measurements for medical and space applications

    CERN Document Server

    Agodi, C; Calabretta, L; Cirrone, G A P C; Cuttone, G; De Napoli, M; Fiorini, F; Giacoppo, F; Mairani, A; Morone, M C; Patera, V; Raciti, G; Rapisarda, E; Ricciardi, V; Romano, F; Sala, P; Sciubba, A

    2010-01-01

    Here we report on preliminary results of an extensive study of fragmentation cross sections measurements useful for medical and space applications. In particular, we looked at the hadrontherapy and space radiation research. Indeed, the measure of fragmentation cross sections is an important information to estimate how this process modifies dose distributions and biological effectiveness, both inside human body and spacecraft. In this picture we started to measure the fragmentation of 12C beam accelerated by the Superconducting Cyclotron at 32 AMeV, 62 AMeV on 12C, 207Pb and 197Au at the INFN Laboratory Nazionali del Sud in Catania (Italy). Preliminary comparison between absolute cross-sections measured for the systems: 12C+207Pb at 32AMeV and for 12C+197Au at 62AMeV is performed.

  9. Why should we keep measuring zenital dependence of muon flux? Results obtained at Campinas (SP) BR

    CERN Document Server

    Daniel, B; Nunes, M; Vieira, T V; Kemp, E

    2013-01-01

    The zenital dependence of muon flux which reaches the earth's surface is well known as proportional to cos^n(\\theta). Generally, for practical purposes and simplicity in calculations, n is taken as 2. However, compilations of measurements show dependence on the geographical location of the experiments as well as the muons energy range. Since analytical solutions appear to be increasingly less necessary because of the higher accessibility to low cost computational power, accurate and precise determination of the value of the exponent n, under different conditions, can be useful in the necessary calculations to estimate signals and backgrounds, either for terrestrial and underground experiments. In this work we discuss a method for measuring n using a simple muon telescope and the results obtained for measurements taken at Campinas (SP), Brazil. After validation of the method, we intend to extend the measurements for different geographic locations due to the simplicity of the method, and thus collect more value...

  10. UNCERTAINTY OF MEASUREMENT- AN IMPORTANT INSTRUMENT TO EVALUATE THE QUALITY OF RESULTS IN FORMALDEHYDE TESTS

    Directory of Open Access Journals (Sweden)

    Emanuela BELDEAN

    2013-09-01

    Full Text Available The measurement uncertainty is a quantitativeindicator of the results quality, meaning how well theresult represents the value of the quantity beingmeasured. It is a relatively new concept and severalguides and regulations were elaborated in order tofacilitate laboratories to evaluate it. The uncertaintycomponents are quantified based on data fromrepeated measurements, previous measurements,knowledge of the equipment and experience of themeasurement. Uncertainity estimation involves arigorous evaluation of possible sources of uncertaintyand good knowledge of the measurement procedure.The case study presented in this paper revealed thebasic steps in uncertainty calculation for formaldehydeemission from wood-based panels determined by the1m3 Chamber method. Based on a very well definedIshikawa Diagram, the expanded uncertainty of0.044mg/m3 for k=2, at 95% confidence level wasestablished.

  11. Classifying, archiving and digitalizing documents related to normal conducting magnets & preparing graphs of magnetic measurement results

    CERN Document Server

    Bayramoglu, Gultug

    2016-01-01

    The main project aims to classify and digitalize documents related to normal conducting magnets. These documents include magnetic measurement results and their graphs, inspection reports, manufacturing reports and so on. The archive of Normal Conducting Magnets Section consists lots of different types of normal conducting magnets documents. Besides these magnet varieties, there are still documents from the times of first accelerator at CERN. In that moment, my project involves to identify, classify and digitalize documents and make them ready to be uploaded in NORMA - database of normal conducting magnets. In addition part of my time I’ve spent on second project, which was preparing graphs of magnetic measurement results of magnets such as current and magnetic field. The aim of these graphs is to compare parameters of magnets the same type and check measurement results’ consistency according to reference points. All of these graphs are on time basis.

  12. Navigation Doppler Lidar Sensor for Precision Altitude and Vector Velocity Measurements Flight Test Results

    Science.gov (United States)

    Pierrottet, Diego F.; Lockhard, George; Amzajerdian, Farzin; Petway, Larry B.; Barnes, Bruce; Hines, Glenn D.

    2011-01-01

    An all fiber Navigation Doppler Lidar (NDL) system is under development at NASA Langley Research Center (LaRC) for precision descent and landing applications on planetary bodies. The sensor produces high resolution line of sight range, altitude above ground, ground relative attitude, and high precision velocity vector measurements. Previous helicopter flight test results demonstrated the NDL measurement concepts, including measurement precision, accuracies, and operational range. This paper discusses the results obtained from a recent campaign to test the improved sensor hardware, and various signal processing algorithms applicable to real-time processing. The NDL was mounted in an instrumentation pod aboard an Erickson Air-Crane helicopter and flown over vegetation free terrain. The sensor was one of several sensors tested in this field test by NASA?s Autonomous Landing and Hazard Avoidance Technology (ALHAT) project.

  13. MAX-DOAS measurements of tropospheric NO2 over San Salvador: preliminary results

    Science.gov (United States)

    Alberti, Carlos; Wagner, Thomas

    2015-04-01

    We present the first Multi-AXis-Differential Optical Absorption Spectroscopy (MAX-DOAS) measurements at San Salvador. MAX-DOAS observes spectra of scattered sun light taken at different elevation angles. From the spectra the so called slant column density (SCD, the integrated trace gas concentration along the atmospheric light path) is derived. We quantify the dSCD of NO2 at different measurement conditions. From the measured NO2 SCDs we calculate the tropospheric vertical column density using the so called geometric approximation. The preliminary results of this MAX DOAS observations and the diurnal variation of the retrieved trace gas dSCDs will be presented. We also use the MAX-DOAS results for the validation of satellite observations.

  14. False positive and false negative radon measurement results due to uncertainties in seasonal correction factors

    Energy Technology Data Exchange (ETDEWEB)

    Cliff, K.D.; Miles, J.C.H.; Naismith, S.P. [National Radiological Protection Board, Chilton (United Kingdom)

    1994-12-31

    Data from the UK national survey of radon in 2300 homes has been re-analysed to determine the uncertainty in seasonal correction factors applied to measurements of less than 1 year. The required correction factor for each six-month result was calculated from the known annual average for the appropriate home. The seasonal correction factors derived for each month were found to be approximately log-normally distributed, with an average geometric standard deviation of 1.36. Following this initial survey, radon measurements have been made in more than 80,000 homes in southwest England to determine whether they are above the UK radon Action Level of 2000 Bq.m{sup -3}. The measurements were carried out over three months in each case using etched track detectors in two locations in each home, and the results were corrected for the average seasonal variation found in the original UK study of radon in homes. Because of the uncertainty in the seasonal correction factors, households with between 130 and 300 Bq.m{sup -3} were advised to have a second three-month measurement in a different season before deciding whether or not to take remedial action. More than 7000 homes were remonitored for this purpose. The results are analysed to show the number of false positive and false negative results that would have been reported if advice had been based solely on the initial measurement. It is shown that the present scheme results in extremely small numbers of false positive and false negative results. (author).

  15. Measurements of meteor smoke particles during the ECOMA-2006 campaign: 2. Results

    Science.gov (United States)

    Strelnikova, Irina; Rapp, Markus; Strelnikov, Boris; Baumgarten, Gerd; Brattli, Alvin; Svenes, Knut; Hoppe, Ulf-Peter; Friedrich, Martin; Gumbel, Jörg; Williams, Bifford P.

    2009-03-01

    The first sounding rocket of the European ECOMA-project (ECOMA, Existence and Charge state Of Meteoric smoke particles in the middle Atmosphere) was launched on 8 September 2006. Measurements with a new particle detector described in the companion paper by Rapp and Strelnikova [2008. Measurements of meteor smoke particles during the ECOMA-2006 campaign: 1. Particle detection by active photoionization. Journal of Atmospheric and Solar-Terrestrial Physics, this issue, doi:10.1016/j.jastp.2008.06.002] clearly showed meteor smoke particle (MSP) signatures in both data channels. The data channels measure particles directly impacting on the detector electrode and photoelectrons from the particles actively created using ionization by the UV-photons of a xenon-flashlamp. Measured photoelectron currents resemble model expectations of the shape of the MSP layer almost perfectly, whereas derived number densities in the altitude range 60-90 km are larger than model results by about a factor of 5. Given the large uncertainties inherent to both model and the analysis of our measurements (e.g., the composition of the particles is not known and must be assumed) we consider this a satisfactory agreement and proof that MSPs do extend throughout the entire mesosphere as predicted by models. The measurements of direct particle impacts revealed a confined layer of negative charge between 80 and 90 km. This limited altitude range, however, is quantitatively shown to be the consequence of the aerodynamics of the rocket flight and does not have any geophysical origin. Measured charge signatures are consistent with expectations of particle charging given our own measurements of the background ionization. Unfortunately, however, a contamination of these measurements from triboelectric charging cannot be excluded at this stage.

  16. Comparative results of corneal curvature measurements with three different keratometers after radial keratotomy

    Institute of Scientific and Technical Information of China (English)

    ZHAO Lu; ZHANG Li; WANG Yan-ling; WANG Wei; YAN Yan

    2011-01-01

    Background Corneal curvatures measured by conventional instruments after refractive surgeries were greater than the real values.This study on the instruments and methods for measuring corneal curvature was carried out with the aim of determining an accurate,simple and effective method to evaluate corneal refractive power after radial keratotomy (RK).Methods A retrospective study was carried out on 52 eyes of 42 patients with a history of RK.The postoperative measurements after RK were performed with a manual keratometer (Rodenstock,Munchen-Hamburg,Germany),a corneal topographer (Tomey TMS-1) and an automated IOLMaster keratometer (Carl Zeiss GmbH,USA).The results obtained from analyzing clinical histories (clinical history method,CHM) were compared to the postoperative measurements with a two-way analysis of variance.Adjusted keratometry was used to correct the corneal central refractive power (K) values of the three keratometers.The CHM results were also compared to the corrected K values obtained with the three keratometers using the same statistical method.Results The smallest mean value was found for the CHM ((36.61±9.23) diopters).The K values obtained with the CHM were very different from the results obtained with the three different instruments.The corrected K values obtained with the IOLMaster were the closest to the K values from the CHM.Conclusions It was shown that K values from measurements with the three instruments were higher.When the power of the intraocular lens of the patients after RK was calculated,the errors of the K values measured with the instruments should be taken into consideration.

  17. 重複觀測量數之分析:多群體多變項線性成長模式的估計Data Analysis of Repeated Measures: Estimating a Multi-Group Multivariate Linear Growth Model

    Directory of Open Access Journals (Sweden)

    溫福星 Fur-Hsing Wen

    2012-03-01

    Full Text Available 本研究利用「台灣教育長期追蹤資料庫」的一般分析能力與數學分析能力的四波調查結果,配合男、女學生樣本進行多群體多條追蹤資料的線性成長模式估計。在考慮重複觀測資料誤差項在不同時點的變異數非同質與不同時點間的共變數非獨立情況下,以及男、女學生的不同成長軌跡,將誤差項結構設為無限制結構,利用虛擬變項交互項法與虛擬變項多樣本法同時估計不同性別、不同能力的線性成長軌跡變化。由於全部追蹤資料樣本存在遺失值的情形,本研究以階層線性模式(hierarchical linear modeling, HLM)軟體對完整資料2,806位學生進行分析,其估計結果發現,在完整資料的兩條成長軌跡模式中,男、女學生誤差項共變異數矩陣結構相同,但線性成長軌跡不恆等。除此之外,本文並對競爭模式比較的結果在文章最後進行討論並提出相關的建議。 This paper demonstrates the data analysis of the repeated measures from the Taiwan Education Panel Survey (TEPS. Based on the four data waves on the TEPS, we consider two abilities (general and mathematic and two population groups (male and female students to construct a multi-group multivariate linear growth model. Because the two-group multivariate repeated measures belong to the different populations and the different research variables, the residual terms of linear growth models may imply heterogeneity of the error covariance structure. We treat the error covariance structure as an unrestricted structure to compare the various types of models. The results from the HLM on the complete data (2,806 students reveal that the male and female students in this study have the same error covariance structure but have distinct linear growth trajectories. In addition, comparisons of the competitive models and related suggestions are discussed in the results and conclusion

  18. 48 CFR 1552.211-80 - Data standards for the transmission of laboratory measurement results.

    Science.gov (United States)

    2010-10-01

    ... Texts of Provisions and Clauses 1552.211-80 Data standards for the transmission of laboratory... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Data standards for the transmission of laboratory measurement results. 1552.211-80 Section 1552.211-80 Federal Acquisition...

  19. Results of measurements at a laboratory condensation heat exchanger with a corrugated minichanel tube

    Directory of Open Access Journals (Sweden)

    Jan Hrubý

    2012-04-01

    Full Text Available This article present a short selection of results obtained from measurements done at a laboratory condensation heat-exchanger with a corrugated mini-channel tube. It also touches a little the metering method and design of the heat-exchanger.

  20. Measurement of diffusion coefficients via diffusion in flowing gas II. Results

    NARCIS (Netherlands)

    Zwakhals, C.J.; Reus, K.W.

    We have applied the back-diffusion method, described in a previous publication (part I), to several noble-gas mixtures; the results are presented here (part II). In the measurements one of the two gases was present always in a relatively small concentration (1%). The diffusion coefficients D

  1. 40 CFR 761.298 - Decisions based on PCB concentration measurements resulting from sampling.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Decisions based on PCB concentration....61(a)(6) § 761.298 Decisions based on PCB concentration measurements resulting from sampling. (a) For grid samples which are chemically analyzed individually, the PCB concentration applies to the area of...

  2. Dissolved Fe(II) in the Pacific Ocean: Measurements from the P16N CLIVAR/CO2 Repeat Hydrography Cruise

    Science.gov (United States)

    Hansard, S. P.; Landing, W. M.; Measures, C. I.

    2006-12-01

    Vertical profiles of seawater Fe(II) concentration were obtained for 37 stations sampled in early 2006, in conjunction with the CLIVAR Repeat Hydrography P16N transect (152° W, Tahiti to Alaska). At each station, seawater samples were collected from 12 target depths (0-1000 m) using trace-metal clean Go-Flo bottles. Upon recovery, Go-Flo bottles were immediately transferred to a Class 100 clean van and sub-sampled for Fe(II) by passing sample water through a 0.2 μm Supor (polyethersulfone) cartridge filter into 125 mL containers, pre-loaded with 25 μL of 6M quartz-distilled HCl (final pH ~~ 6) to slow oxidation. Samples were immediately analyzed for Fe(II) using a luminol-based chemiluminescence method. Total dissolved iron was also determined shipboard by spectrophotometric flow injection analysis. The data collected from this cruise will be presented, along with corroborating data from another North Pacific cruise (PO2). Concentrations of Fe(II) ranged from below detection (meters. Photoreduction of Fe(III) has been cited as a source of Fe(II) in surface waters, and the pattern of attenuation with depth is consistent with this mechanism. Many samples collected at or near the bottom of the profile (500-1000 m) exhibited elevated Fe(II) relative to the mid-depths of the profile. Due to the higher total dissolved iron at depth, the percentage of Fe(II) was low in these samples. Recent studies support the presence of Fe(II) at depth, in association with low or suboxic conditions. In situ processes such as the remineralization of sinking biogenic particles may provide a source for this Fe(II).

  3. Strengthening concept learning by repeated testing.

    Science.gov (United States)

    Wiklund-Hörnqvist, Carola; Jonsson, Bert; Nyberg, Lars

    2014-02-01

    The aim of this study was to examine whether repeated testing with feedback benefits learning compared to rereading of introductory psychology key-concepts in an educational context. The testing effect was examined immediately after practice, after 18 days, and at a five-week delay in a sample of undergraduate students (n = 83). The results revealed that repeated testing with feedback significantly enhanced learning compared to rereading at all delays, demonstrating that repeated retrieval enhances retention compared to repeated encoding in the short- and the long-term. In addition, the effect of repeated testing was beneficial for students irrespectively of working memory capacity. It is argued that teaching methods involving repeated retrieval are important to consider by the educational system.

  4. Repeatability of Response to Asthma Medications

    Science.gov (United States)

    Wu, Ann; Tantisira, Kelan; Li, Lingling; Schuemann, Brooke; Weiss, Scott

    2010-01-01

    Background Pharmacogenetic studies of drug response in asthma assume that patients respond consistently to a treatment but that treatment response varies across patients, however, no formal studies have demonstrated this. Objective To determine the repeatability of commonly used outcomes for treatment response to asthma medications: bronchodilator response, forced expiratory volume in 1 second (FEV1), and provocative concentration of methacholine producing a 20% decline in FEV1 (PC20). Methods The Childhood Asthma Management Program (CAMP) was a multi-center clinical trial of children randomized to receiving budesonide, nedocromil, or placebo. We determined the intraclass correlation coefficient (ICC) for each outcome over repeated visits over four years in CAMP using mixed effects regression models. We adjusted for the covariates: age, race/ethnicity, height, family income, parental education, and symptom score. We incorporated each outcome for each child as repeated outcome measurements and stratified by treatment group. Results The ICC for bronchodilator response was 0.31 in the budesonide group, 0.35 in the nedocromil group, and 0.40 in the placebo group, after adjusting for covariates. The ICC for FEV1 was 0.71 in the budesonide group, 0.60 in the nedocromil group, and 0.69 in the placebo group, after adjusting for covariates. The ICC for PC20 was 0.67 in the budesonide and placebo groups and 0.73 in the nedocromil group, after adjusting for covariates. Conclusion The within treatment group repeatability of FEV1 and PC20 are high; thus these phenotypes are heritable. FEV1 and PC20 may be better phenotypes than bronchodilator response for studies of treatment response in asthma. PMID:19064281

  5. Measurement of personal dose equivalent of X and gamma radiation by ring dosimeter: Results of intercomparison measurements

    Directory of Open Access Journals (Sweden)

    Małgorzata Adamowicz

    2013-10-01

    Full Text Available Background: The aim of the study was to present the results of the interlaboratory comparisons for ring dosimeters and to confirm that the applied method is suitable for measuring the personal dose equivalent HP(0.07. In addition, calibration procedures used in dosimetric measurements in persons occupationally exposed to ionizing photon radiation X and γ were presented. Materials and Methods: Ring dosimeters made of flexible plastics with the diameter of approximately 20 mm, equipped with two thermoluminescence (TL detectors type MTS-N, were the subject of interlaboratory comparisons. Irradiated detectors were red out using a new manual TLD's reader (FIMEL, France. All TLD exposures were done for validation of TLD readers and were performed using the reference X-ray and γ beams with the ISO rod phantom. The methodology of performed exposures corresponded with the methods applied by the European Radiation Dosimetry Group (EURADOS, the European organizer of interlaboratory comparisons. Results: The energy, dose and angular characteristics of the ring dosimeter allowed to elaborate the formula for estimating and verifying the personal dose equivalent HP(0.07. The test was performed to check and confirm the correctness of the estimated characteristics. The test results were satisfactory, and thus the readiness to implement TLD reader in the used method and to participate in interlaboratory comparisons was confirmed. Conclusions: According to the requirements of the Polish Centre for Accreditation, the laboratory was participating in the interlaboratory comparison organized by EURADOS in terms of the personal dose equivalent HP(0.07. The result of the comparison was satisfactory, therefore the correctness of the testing procedure was confirmed. Med Pr 2013;64(5:631–637

  6. Using the ratio of means as the effect size measure in combining results of microarray experiments

    Directory of Open Access Journals (Sweden)

    Greenwood Celia MT

    2009-11-01

    Full Text Available Abstract Background Development of efficient analytic methodologies for combining microarray results is a major challenge in gene expression analysis. The widely used effect size models are thought to provide an efficient modeling framework for this purpose, where the measures of association for each study and each gene are combined, weighted by the standard errors. A significant disadvantage of this strategy is that the quality of different data sets may be highly variable, but this information is usually neglected during the integration. Moreover, it is widely known that the estimated standard deviations are probably unstable in the commonly used effect size measures (such as standardized mean difference when sample sizes in each group are small. Results We propose a re-parameterization of the traditional mean difference based effect measure by using the log ratio of means as an effect size measure for each gene in each study. The estimated effect sizes for all studies were then combined under two modeling frameworks: the quality-unweighted random effects models and the quality-weighted random effects models. We defined the quality measure as a function of the detection p-value, which indicates whether a transcript is reliably detected or not on the Affymetrix gene chip. The new effect size measure is evaluated and compared under the quality-weighted and quality-unweighted data integration frameworks using simulated data sets, and also in several data sets of prostate cancer patients and controls. We focus on identifying differentially expressed biomarkers for prediction of cancer outcomes. Conclusion Our results show that the proposed effect size measure (log ratio of means has better power to identify differentially expressed genes, and that the detected genes have better performance in predicting cancer outcomes than the commonly used effect size measure, the standardized mean difference (SMD, under both quality-weighted and quality

  7. Mutations in zebrafish leucine-rich repeat-containing six-like affect cilia motility and result in pronephric cysts, but have variable effects on left-right patterning.

    Science.gov (United States)

    Serluca, Fabrizio C; Xu, Bo; Okabe, Noriko; Baker, Kari; Lin, Shin-Yi; Sullivan-Brown, Jessica; Konieczkowski, David J; Jaffe, Kimberly M; Bradner, Joshua M; Fishman, Mark C; Burdine, Rebecca D

    2009-05-01

    Cilia defects have been implicated in a variety of human diseases and genetic disorders, but how cilia motility contributes to these phenotypes is still unknown. To further our understanding of how cilia function in development, we have cloned and characterized two alleles of seahorse, a zebrafish mutation that results in pronephric cysts. seahorse encodes Lrrc6l, a leucine-rich repeat-containing protein that is highly conserved in organisms that have motile cilia. seahorse is expressed in zebrafish tissues known to contain motile cilia. Although mutants do not affect cilia structure and retain the ability to interact with Disheveled, both alleles of seahorse strongly affect cilia motility in the zebrafish pronephros and neural tube. Intriguingly, although seahorse mutations variably affect fluid flow in Kupffer's vesicle, they can have very weak effects on left-right patterning. Combined with recently published results, our alleles suggest that the function of seahorse in cilia motility is separable from its function in other cilia-related phenotypes.

  8. Intercomparison of magnetic field measurements near MV/LV transformer substations: methodological planning and results.

    Science.gov (United States)

    Violanti, S; Fraschetta, M; Adda, S; Caputo, E

    2009-12-01

    Within the framework of Environmental Agencies system's activities, coordinated by ISPRA (superior institute for environmental protection and research), a comparison among measurements was designed and accomplished, in order to go into depth on the matter of measurement problems and to evaluate magnetic field at power frequencies. These measurements have been taken near medium voltage /low voltage transformer substation. This project was developed with the contribution of several experts who belong to different Regional Agencies. In three of these regions, substations having specific international standard characteristics were chosen; then a measurement and data analysis protocol was arranged. Data analysis showed a good level of coherence among results obtained by different laboratories. However, a range of problems emerged, either during the protocol predisposition and definition of the data analysis procedure or during the execution of measures and data reprocessing, because of the spatial and temporal variability of magnetic field. These problems represent elements of particular interest in determining a correct measurement methodology, whose purpose is the comparison with limits of exposure, attention values and quality targets.

  9. Two to five repeated measurements per patient reduced the required sample size considerably in a randomized clinical trial for patients with inflammatory rheumatic diseases

    OpenAIRE

    Smedslund Geir; Zangi Heidi Andersen; Mowinckel Petter; Hagen Kåre Birger

    2013-01-01

    Abstract Background Patient reported outcomes are accepted as important outcome measures in rheumatology. The fluctuating symptoms in patients with rheumatic diseases have serious implications for sample size in clinical trials. We estimated the effects of measuring the outcome 1-5 times on the sample size required in a two-armed trial. Findings In a randomized controlled trial that evaluated the effects of a mindfulness-based group intervention for patients with inflammatory arthritis (n=71)...