WorldWideScience

Sample records for repeatable liquid chromatography

  1. Liquid Chromatography in 1982.

    Science.gov (United States)

    Freeman, David H.

    1982-01-01

    Reviews trends in liquid chromatography including apparatus, factors affecting efficient separation of a mixture (peak sharpness and speed), simplified problem-solving, adsorption, bonded phase chromatography, ion selectivity, and size exclusion. The current trend is to control chemical selectivity by the liquid phase. (Author/JN)

  2. Column Liquid Chromatography.

    Science.gov (United States)

    Majors, Ronald E.; And Others

    1984-01-01

    Reviews literature covering developments of column liquid chromatography during 1982-83. Areas considered include: books and reviews; general theory; columns; instrumentation; detectors; automation and data handling; multidimensional chromatographic and column switching techniques; liquid-solid chromatography; normal bonded-phase, reversed-phase,…

  3. High Performance Liquid Chromatography

    Science.gov (United States)

    Talcott, Stephen

    High performance liquid chromatography (HPLC) has many applications in food chemistry. Food components that have been analyzed with HPLC include organic acids, vitamins, amino acids, sugars, nitrosamines, certain pesticides, metabolites, fatty acids, aflatoxins, pigments, and certain food additives. Unlike gas chromatography, it is not necessary for the compound being analyzed to be volatile. It is necessary, however, for the compounds to have some solubility in the mobile phase. It is important that the solubilized samples for injection be free from all particulate matter, so centrifugation and filtration are common procedures. Also, solid-phase extraction is used commonly in sample preparation to remove interfering compounds from the sample matrix prior to HPLC analysis.

  4. Micellar liquid chromatography

    Science.gov (United States)

    Basova, Elena M.; Ivanov, Vadim M.; Shpigun, Oleg A.

    1999-12-01

    Background and possibilities of practical applications of micellar liquid chromatography (MLC) are considered. Various retention models in MLC, the effects of the nature and concentration of surfactants and organic modifiers, pH, temperature and ionic strength on the MLC efficiency and selectivity are discussed. The advantages and limitations of MLC are demonstrated. The performance of MLC is critically evaluated in relationship to the reversed-phase HPLC and ion-pair chromatography. The potential of application of MLC for the analysis of pharmaceuticals including that in biological fluids and separation of inorganic anions, transition metal cations, metal chelates and heteropoly compounds is described. The bibliography includes 146 references.

  5. Assessment of repeatability of composition of perfumed waters by high-performance liquid chromatography combined with numerical data analysis based on cluster analysis (HPLC UV/VIS - CA).

    Science.gov (United States)

    Ruzik, L; Obarski, N; Papierz, A; Mojski, M

    2015-06-01

    High-performance liquid chromatography (HPLC) with UV/VIS spectrophotometric detection combined with the chemometric method of cluster analysis (CA) was used for the assessment of repeatability of composition of nine types of perfumed waters. In addition, the chromatographic method of separating components of the perfume waters under analysis was subjected to an optimization procedure. The chromatograms thus obtained were used as sources of data for the chemometric method of cluster analysis (CA). The result was a classification of a set comprising 39 perfumed water samples with a similar composition at a specified level of probability (level of agglomeration). A comparison of the classification with the manufacturer's declarations reveals a good degree of consistency and demonstrates similarity between samples in different classes. A combination of the chromatographic method with cluster analysis (HPLC UV/VIS - CA) makes it possible to quickly assess the repeatability of composition of perfumed waters at selected levels of probability. © 2014 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  6. Principles of Liquid Chromatography

    Science.gov (United States)

    Bakalyar, Stephen R.

    This article reviews the basic principles of high performance liquid chromatography (HPLC). The introductory section provides an overview of the HPLC technique, placing it in historical context and discussing the elementary facts of the separation mechanism. The next section discusses the nature of resolution, describing the two principal aspects, zone center separation and zone spreading. The third section takes a detailed look at how HPLC is used in practice to achieve a separation. It discusses the three key variables that need to be adjusted: retention, efficiency, and selectivity. A fourth section is concerned with various relationships of practical importance: flow rate, temperature, and pressure. A final section discusses future trends in HPLC.

  7. General strategies to increase the repeatability in non-target screening by liquid chromatography-high resolution mass spectrometry.

    Science.gov (United States)

    Bader, Tobias; Schulz, Wolfgang; Kümmerer, Klaus; Winzenbacher, Rudi

    2016-09-01

    This article focuses on the data evaluation of non-target high-resolution LC-MS profiles of water samples. Taking into account multiple technical replicates, the difficulties in peak recognition and the related problems of false positive and false negative findings are systematically demonstrated. On the basis of a combinatorial approach, different models involving sophisticated workflows are evaluated, particularly with regard to the repeatability. In addition, the improvement resulting from data processing was systematically taken into consideration where the recovery of spiked standards emphasized that real peaks of interest were barely or not removed by the derived filter criteria. The comprehensive evaluation included different matrix types spiked with up to 263 analytical standards which were analyzed repeatedly leading to a total number of more than 250 injections that were incorporated in the assessment of different models of data processing. It was found that the analysis of multiple replicates is the key factor as, on the one hand, it provides the option of integrating valuable filters in order to minimize the false positive rate and, on the other hand, allows correcting partially false negative findings occurring during the peak recognition. The developed processing strategies including replicates clearly point to an enhanced data quality since both the repeatability as well as the peak recognition could be considerably improved. As proof of concept, four different matrix types, including a wastewater treatment plant (WWTP) effluent, were spiked with 130 isotopically labeled standards at different concentration levels. Despite the stringent filter criteria, at 100 ng L(-1) recovery rates of up to 93% were reached in the positive ionization mode. The proposed model, comprising three technical replicates, filters less than 5% and 2% of the standards recognized at 100 and 500 ng L(-1), respectively and thus indicates the general applicability of the

  8. Introduction to modern liquid chromatography

    National Research Council Canada - National Science Library

    Snyder, Lloyd R; Kirkland, J. J; Dolan, John W

    2010-01-01

    "High-performance liquid chromatography (HPLC) is today the leading technique for chemical analysis and related applications, with an ability to separate, analyze, and/or purify virtually any sample...

  9. Two-dimensional liquid chromatography

    DEFF Research Database (Denmark)

    Græsbøll, Rune

    of this thesis is on online comprehensive two-dimensional liquid chromatography (online LC×LC) with reverse phase in both dimensions (online RP×RP). Since online RP×RP has not been attempted before within this research group, a significant part of this thesis consists of knowledge and experience gained...

  10. Separation of whey proteins for chromatography liquid

    OpenAIRE

    Abraham D. Giraldo Zuñiga; Edwin E.García Rojas; Jane S. R. Coimbra; Wilmer E. Luera Peña

    2010-01-01

    This paper describes and compares three chromatographic methods for the analysis and quantification of most abundant proteins in cheese whey, -lactalbumin and -lactoglobulin. The methods were: Reverse-phase high performance liquid chromatography, anion Exchange chromatography and size-exclusion chromatography. The reverse- phase liquid chromatography led to a better separation of whey proteins than size-exclusion chromatography and anion exchange chromatography, this method offered an excel...

  11. Two-dimensional liquid chromatography

    DEFF Research Database (Denmark)

    Græsbøll, Rune

    Two-dimensional liquid chromatography has received increasing interest due to the rise in demand for analysis of complex chemical mixtures. Separation of complex mixtures is hard to achieve as a simple consequence of the sheer number of analytes, as these samples might contain hundreds or even...... dimensions. As a consequence of the conclusions made within this thesis, the research group has, for the time being, decided against further development of online LC×LC systems, since it was not deemed ideal for the intended application, the analysis of the polar fraction of oil. Trap-and...

  12. Liquid phase chromatography on microchips.

    Science.gov (United States)

    Kutter, Jörg P

    2012-01-20

    Over the past twenty years, the field of microfluidics has emerged providing one of the main enabling technologies to realize miniaturized chemical analysis systems, often referred to as micro-Total Analysis Systems (uTAS), or, more generally, Lab-on-a-Chip Systems (LOC) [1,2]. While microfluidics was driven forward a lot from the engineering side, especially with respect to ink jet and dispensing technology, the initial push and interest from the analytical chemistry community was through the desire to develop miniaturized sensors, detectors, and, very early on, separation systems. The initial almost explosive development of, in particular, chromatographic separation systems on microchips, has, however, slowed down in recent years. This review takes a closer, critical look at how liquid phase chromatography has been implemented in miniaturized formats over the past several years, what is important to keep in mind when developing or working with separations in a miniaturized format, and what challenges and pitfalls remain.

  13. Liquid phase chromatography on microchips

    DEFF Research Database (Denmark)

    Kutter, Jörg Peter

    2012-01-01

    Over the past twenty years, the field of microfluidics has emerged providing one of the main enabling technologies to realize miniaturized chemical analysis systems, often referred to as micro-Total Analysis Systems (uTAS), or, more generally, Lab-on-a-Chip Systems (LOC) [1,2]. While microfluidics...... was driven forward a lot from the engineering side, especially with respect to ink jet and dispensing technology, the initial push and interest from the analytical chemistry community was through the desire to develop miniaturized sensors, detectors, and, very early on, separation systems. The initial almost...... explosive development of, in particular, chromatographic separation systems on microchips, has, however, slowed down in recent years. This review takes a closer, critical look at how liquid phase chromatography has been implemented in miniaturized formats over the past several years, what is important...

  14. Mixed Stationary Liquid Phases for Gas-Liquid Chromatography.

    Science.gov (United States)

    Koury, Albert M.; Parcher, Jon F.

    1979-01-01

    Describes a laboratory technique for use in an undergraduate instrumental analysis course that, using the interpretation of window diagrams, prepares a mixed liquid phase column for gas-liquid chromatography. A detailed procedure is provided. (BT)

  15. Application of fast liquid chromatography for antioxidants analysis

    Directory of Open Access Journals (Sweden)

    Agnieszka Drożdżyńska

    2012-03-01

    Full Text Available Background. An intensive development of the Fast Liquid Chromatography (FLC has been recently observed. It makes possible to reduce time analysis and improve resolution as well as sensitivity. The aim of this study was to separate the chosen antioxidants optimization using the FLC method. Material  and methods. The three various procedures for antioxidants analysis were compared. Mobile phases containing aqueous solution of formic acid, acetic acid, acetonitrile, and methanol were tested. Limit of detection (LOD, limit of quantification (LOQ, linearity and repeatability of each procedures were determined. Results. Developed procedure enabled to separate all analytes and allowed to get low LOD levels and good repeatability. This procedure was used for antioxidants analysis in buckwheat and buckwheat products. Conclusion. Fast Liquid Chromatography allows to  reduce time analysis and  obtain good  validation parameters.

  16. Low thermal mass liquid chromatography.

    Science.gov (United States)

    Gu, Binghe; Cortes, Hernan; Luong, Jim; Pursch, Matthias; Eckerle, Patric; Mustacich, Robert

    2009-02-15

    A novel technique, low thermal mass liquid chromatography (LTMLC), is introduced in this study. The use of an LTM assembly that utilizes the principle of resistive wire heating and a temperature sensor to accurately deliver unprecedented heating (up to 1800 degrees C/min) or cooling (100 to approximately 200 degrees C/min) rates is reported. With the use of packed microcolumns (heat transfer from the assembly to the mobile phase was obtained. A systematic investigation was conducted to study the performance of the LTMLC technique. Both isocratic and gradient mobile phase conditions were used. For temperature control, isothermal, temperature-increasing, and temperature-decreasing gradients were applied. Three model mixtures, two of which containing neutral and acidic analytes and the other containing neutral, acidic, and basic analytes, were used to study the effect of temperature on elution time, resolution, column efficiency, and selectivity. It was found that the LTMLC experimental setup delivered reliable temperature control, as evidenced by linear van't Hoff plots for neutral and acidic compounds. The effect of temperature on the elution of basic analytes yielded nonlinear van't Hoff plots, explaining the dramatic selectivity changes observed for bases with changes in column temperature. Column efficiency generally increased with the increase in column temperature in the range of 25 to approximately 75 degrees C and decreased in the range of 75 to approximately 150 degrees C at a fixed column flow rate (3 microL/min), when extra column band broadening was taken into account. The increase in efficiency upon the increase in column temperature in the low temperature range was mainly due to the decreased mass transfer term resulting from increased analyte diffusivity. However, under even higher temperatures, the longitudinal diffusion dominated band broadening, explaining the decrease in column efficiency upon a further increase in column temperature. Resolution

  17. Liquid chromatography detection unit, system, and method

    Energy Technology Data Exchange (ETDEWEB)

    Derenzo, Stephen E.; Moses, William W.

    2015-10-27

    An embodiment of a liquid chromatography detection unit includes a fluid channel and a radiation detector. The radiation detector is operable to image a distribution of a radiolabeled compound as the distribution travels along the fluid channel. An embodiment of a liquid chromatography system includes an injector, a separation column, and a radiation detector. The injector is operable to inject a sample that includes a radiolabeled compound into a solvent stream. The position sensitive radiation detector is operable to image a distribution of the radiolabeled compound as the distribution travels along a fluid channel. An embodiment of a method of liquid chromatography includes injecting a sample that comprises radiolabeled compounds into a solvent. The radiolabeled compounds are then separated. A position sensitive radiation detector is employed to image distributions of the radiolabeled compounds as the radiolabeled compounds travel along a fluid channel.

  18. Liquid chromatography detection unit, system, and method

    Science.gov (United States)

    Derenzo, Stephen E.; Moses, William W.

    2015-10-27

    An embodiment of a liquid chromatography detection unit includes a fluid channel and a radiation detector. The radiation detector is operable to image a distribution of a radiolabeled compound as the distribution travels along the fluid channel. An embodiment of a liquid chromatography system includes an injector, a separation column, and a radiation detector. The injector is operable to inject a sample that includes a radiolabeled compound into a solvent stream. The position sensitive radiation detector is operable to image a distribution of the radiolabeled compound as the distribution travels along a fluid channel. An embodiment of a method of liquid chromatography includes injecting a sample that comprises radiolabeled compounds into a solvent. The radiolabeled compounds are then separated. A position sensitive radiation detector is employed to image distributions of the radiolabeled compounds as the radiolabeled compounds travel along a fluid channel.

  19. High-performance liquid chromatography of biopolymers

    Energy Technology Data Exchange (ETDEWEB)

    Regnier, F.E.

    1983-10-21

    The ability to separate biological macromolecules with good resolution on liquid chromatographic columns has depended on the development of suitable packing materials. In size exclusion chromatography, molecules are separated by size on the basis of differential permeation of the packing. Ion exchange, hydrophobic interaction (or reversed-phase), and affinity chromatography are all surface-mediated separation methods, although they depend on different retention mechanisms. High-performance liquid chromatographic columns designed for biopolymers offer major advantages over conventional columns in both speed and resolving power. The exponential growth of literature on the high-performance separation of peptides and proteins in particular indicates that the techniques will become the dominant form of column liquid chromatography. 92 refs., 4 figs.

  20. Instrument platforms for nano liquid chromatography.

    Science.gov (United States)

    Šesták, Jozef; Moravcová, Dana; Kahle, Vladislav

    2015-11-20

    The history of liquid chromatography started more than a century ago and miniaturization and automation are two leading trends in this field. Nanocolumn liquid chromatography (nano LC) and largely synonymous capillary liquid chromatography (capillary LC) are the most recent results of this process where miniaturization of column dimensions and sorbent particle size play crucial role. Very interesting results achieved in the research of extremely miniaturized LC columns at the end of the last century lacked distinctive raison d'être and only advances in mass spectrometry brought a real breakthrough. Configuration of nano LC-electrospray ionization mass spectrometry (LC-ESI-MS) has become a basic tool in bioanalytical chemistry, especially in proteomics. This review discusses and summarizes past and current trends in the realization of nano liquid chromatography (nano LC) platforms. Special attention is given to the mobile phase delivery under nanoflow rates (isocratic, gradient) and sample injection to the nanocolumn. Available detection techniques applied in nano LC separations are also briefly discussed. We followed up the key themes from the original scientific reports over gradual improvements up to the contemporary commercial solutions.

  1. Liquid chromatography of organophosphorus acids

    NARCIS (Netherlands)

    Verweij, A.; Kientz, C.E.; Berg, J. van den

    1988-01-01

    The applicability of different liquid chromatographic systems such as ion-exchange, ion-exclusion, reversed phase and ion-pair partition was studied for the analysis of a number of simple structurally related organophosphorus acids which lack a chromophoric group. Preliminary experiments based on th

  2. Flow Rates in Liquid Chromatography, Gas Chromatography and Supercritical Fluid Chromatography: A Tool for Optimization

    OpenAIRE

    Joris Meurs

    2016-01-01

    This paper aimed to develop a standalone application for optimizing flow rates in liquid chromatography (LC), gas chromatography (GC) and supercritical fluid chromatography (SFC). To do so, Van Deemter’s equation, Knox’ equation and Golay’s equation were implemented in a MATLAB script and subsequently a graphical user interface (GUI) was created. The application will show the optimal flow rate or linear velocity and the corresponding plate height for the set input parameters. Furthermore, a p...

  3. High Performance Liquid Chromatography Experiments to Undergraduate Laboratories

    Science.gov (United States)

    Kissinger, Peter T.; And Others

    1977-01-01

    Reviews the principles of liquid chromatography with electrochemical detection (LCEC), an analytical technique that incorporates the advantages of both liquids chromatography and electrochemistry. Also suggests laboratory experiments using this technique. (MLH)

  4. Instrumentation for hand-portable liquid chromatography.

    Science.gov (United States)

    Sharma, Sonika; Plistil, Alex; Simpson, Robert S; Liu, Kun; Farnsworth, Paul B; Stearns, Stanley D; Lee, Milton L

    2014-01-31

    Liquid chromatography (LC) has lagged behind gas chromatography (GC) in developments related to hand-portable instrumentation. In this work, a new battery-operated (24V DC) nano-flow pumping system with a stop-flow injector was developed and integrated with an on-column UV-absorption detector (254nm) that was reduced in size to an acceptable weight and power usage for field operation. The pumping system, which includes nano-flow pump, stepper motor and high-pressure valve weighs only 1.372kg (3lbs) and can generate up to 110.32MPa (16,000psi) pressure. A major advantage of this pump is that it does not employ a splitter, since it was specifically designed for capillary column use. The volume capacity of the pump is 24μL, and a sample volume as low as 10nL can be injected. Flow rate calibration (300nL to 6.12μL per min) was performed, and an accuracy >99.94% was obtained. The percent injection carry-over was found to be low (RSD 0.31%), which makes it practical for quantitative analysis. The detector linear range and limit of detection (LOD) were determined using sodium anthraquinone-2-sulfonate. A linear regression coefficient (R) of 0.9996 was obtained for a plot of log peak area versus log concentration over the range of 3.2μM to 6.5mM, and the LOD (S/N=3) was found to be 7.8fmol (0.13μM). The short term noise of the detector is comparable to commercially available detectors (∼10(-5)AU). In this work, the system was tested in the laboratory using regular line power (120V AC) with an AC to DC adapter. Reversed-phase isocratic separations were performed using a 15.5cm×75μm i.d. fused silica capillary column containing a monolithic stationary phase synthesized from 1,6-hexanediol dimethacrylate. Good retention time repeatability (RSD 0.09-0.74%) was obtained for a mixture containing an unretained marker (i.e., uracil) and a homologous series of alkyl benzenes.

  5. High Performance Liquid Chromatography/Video Fluorometry. Part I. Instrumentation.

    Science.gov (United States)

    1981-09-30

    High Performance Liquid Chromatography /Video...PERIOD COVERED High Performance Liquid Chromatography /Video .. / Fluorometry. Part I. Instrumentation. . Interim/ echnicaliepart,. 6. PERFORMING ORG...34Entered SECURITY CLASSIFICATION OF THIS OlAGE (When Data Entered) II1| III I I I I E I II ... .. High Performance Liquid Chromatography

  6. Optimized determination of polybrominated diphenyl ethers by ultrasound-assisted liquid-liquid extraction and high-performance liquid chromatography.

    Science.gov (United States)

    He, Kuang; Lv, YuanCai; Chen, YuanCai

    2014-10-01

    A method based on ultrasound-assisted liquid-liquid extraction and high-performance liquid chromatography has been optimized for the determination of six polybrominated diphenyl ether congeners. The optimal condition relevant to the extraction was first investigated, more than 98.7 ± 0.7% recovery was achieved with dichloromethane as extractant, 5 min extraction time, and three cycles of ultrasound-assisted liquid-liquid extraction. Then multiple function was employed to optimize polybrominated diphenyl ether detection conditions with overall resolution and chromatography signal area as the responses. The condition chosen in this experiment was methanol/water 93:7 v/v, flow rate 0.80 mL/min, column temperature 30.0°C. The optimized technique revealed good linearity (R(2) > 0.9962 over a concentration range of 1-100 μg/L) and repeatability (relative standard deviation liquid-liquid extraction coupled with high-performance liquid chromatography was effective to identify and quantify the complex polybrominated diphenyl ethers in effluent samples.

  7. Fiber Bragg grating photoacoustic detector for liquid chromatography.

    Science.gov (United States)

    Yang, Qingxin; Loock, Hans-Peter; Kozin, Igor; Pedersen, David

    2008-11-01

    Fiber Bragg Gratings (FBGs) are known to be sensitive acoustic transducers and have previously been used for the photoacoustic detection of small solid samples. Here, we demonstrate the use of an FBG as an on-line detector for liquid chromatography. The FBG was inserted into a silica capillary and the photoacoustic response from the effluent was generated by a 10 ns pulsed laser. The acoustic pulse was quantified by the FBG through a characteristic change in the reflection spectrum. Good repeatability and linear response were obtained over three orders of magnitude (R(2) > 0.99), and the limit of detection of Coumarin 440 was determined to be 5 microM. The technique was successfully coupled to high performance liquid chromatography and applied to on-line analysis of a three-compound solution. Photoacoustic detection in liquid chromatography using FBGs is a label-free method, which can be applied to the detection of any chromogenic compound irrespective of its fluorogenic properties. It is a simple, inexpensive, and inherently micron-sized technique, insensitive to electromagnetic interference.

  8. Basic prinicipal of high performance liquid chromatography

    OpenAIRE

    Ivanova, Violeta

    2016-01-01

    High-performance liquid chromatography (HPLC) is an analytical technique based on the separation of molecules due to differences in their structure and/or composition. Separation is performed between two phases, mobile and stationary. The molecules in the sample have different affinities and interactions with the stationary support, leading to separation of molecules. Compounds which are longer retained at the stationary phase will elute later, compared to those which are distributed into the...

  9. Recent applications of hydrophilic interaction liquid chromatography in pharmaceutical analysis.

    Science.gov (United States)

    Zhang, Qian; Yang, Feng-Qing; Ge, Liya; Hu, Yuan-Jia; Xia, Zhi-Ning

    2017-01-01

    Hydrophilic interaction liquid chromatography, an alternative liquid chromatography mode, is of particular interest in separating hydrophilic and polar ionic compounds. Compared with traditional liquid chromatography techniques, hydrophilic interaction liquid chromatography offers specific advantages mainly including: (1) relatively green and water-soluble mobile phase composition, which enhances the solubility of hydrophilic and polar ionic compounds; (2) no need for ion-pairing reagents and high content of organic solvent, which benefits mass spectrometry detection; (3) high orthogonality to reverse-phase liquid chromatography, well adapted to two-dimensional liquid chromatography for complicated samples. Therefore, hydrophilic interaction liquid chromatography has been rapidly developed in many areas over the past decades. This review summarizes the recent progress (from 2012 to July 2016) of hydrophilic interaction liquid chromatography in pharmaceutical analysis, with the focus on detecting chemical drugs in various matrices, charactering active compounds of natural products and assessing biotherapeutics through typical structure unit. Moreover, the retention mechanism and behavior of analytes in hydrophilic interaction liquid chromatography as well as some novel hydrophilic interaction liquid chromatography columns used for pharmaceutical analysis are also described.

  10. High Performance Liquid Chromatography/Video Fluorometry. Part II. Applications.

    Science.gov (United States)

    1981-09-30

    HIGH PERFORMANCE LIQUID CHROMATOGRAPHY /VIDEO FLUOROMETRY. PART...REP«T_N&:-ŗ/ High Performance Liquid Chromatography /Video Fluorometry» Part II. Applications« by | Dennis C./Shelly* Michael P./Vogarty and...Data EnlirtdJ REPORT DOCUMENTATION PAGE t. REPORT NUMBER 2 GOVT ACCESSION NO 4. T1TI.F (and Submit) lP-^fffsyva High Performance Liquid Chromatography

  11. Simulating retention in gas-liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Martin, M.G.; Siepmann, J.I.; Schure, M.R.

    1999-12-16

    Accurate predictions of retention times, retention indices, and partition constants are a long sought-after goal for theoretical studies in chromatography. Configurational-bias Monte Carlo (CBMC) simulations in the Gibbs ensemble using the transferable potentials for phase equilibria-united atom (TraPPE-UA) force field have been carried out to obtain a microscopic picture of the partitioning of 10 alkane isomers between a helium vapor phase and a squalane liquid phase, a protypical gas-liquid chromatography system. The alkane solutes include some topological isomers that differ only in the arrangement of their building blocks (e.g., 2,5-dimethylhexane and 3,4-dimethylhexane), for which the prediction of the retention order is particularly difficult. The Kovats retention indices, a measure of the relative retention times, are calculated directly from the partition constants and are in good agreement with experimental values. The calculated Gibbs free energies of transfer for the normal alkanes conform to Martin's equation which is the basis of linear free energy relationships used in many process modeling packages. Analysis of radial distribution functions and the corresponding energy integrals does not yield evidence for specific retention structures and shows that the internal energy of solvation is not the main driving force for the separation of topological isomers in this system.

  12. Pressurized liquid extraction followed by liquid chromatography with tandem mass spectrometry to determine pharmaceuticals in mussels.

    Science.gov (United States)

    Núñez, Mireia; Borrull, Francesc; Pocurull, Eva; Fontanals, Núria

    2016-02-01

    An analytical method based on pressurized liquid extraction and solid-phase extraction with a mixed-mode Oasis(®) MAX sorbent as cleanup, followed by liquid chromatography with electrospray ionization and tandem mass spectrometry was developed and validated for the determination of seven widely used pharmaceuticals in mussel species. The optimization of the pressurized liquid extraction and the solid-phase extraction parameters is described. The method provided extraction recoveries ranging from 61 to 90%, and limits of detection ranging from 2 to 50 ng/g (dry weight). The repeatability and reproducibility of the method, expressed as relative standard deviation, were lower than 15 and 19%, respectively. The method was successfully applied to the analysis of mussel samples from different locations. The analyses showed that salicylic acid was present in mussels at concentrations up to 177 ng/g (dry weight).

  13. Comprehensive two-dimensional liquid chromatography: Ion chromatography × reversed-phase liquid chromatography for separation of low-molar-mass organic acids

    NARCIS (Netherlands)

    S.S. Brudin; R.A. Shellie; P.R. Haddad; P.J. Schoenmakers

    2010-01-01

    In the work presented here a novel approach to comprehensive two-dimensional liquid chromatography is evaluated. Ion chromatography is chosen for the first-dimension separation and reversed-phase liquid chromatography is chosen for the second-dimension separation mode. The coupling of these modes is

  14. Comparison of liquid chromatography-microchip/mass spectrometry to conventional liquid chromatography-mass spectrometry for the analysis of steroids.

    Science.gov (United States)

    Ahonen, Linda; Keski-Rahkonen, Pekka; Saarelainen, Taija; Paviala, Jenni; Ketola, Raimo A; Auriola, Seppo; Poutanen, Matti; Kostianen, Risto

    2012-04-01

    The feasibility of a microfluidic-based liquid chromatography-electrospray ionization/mass spectrometric system (HPLC-Chip/ESI/MS) was studied and compared to a conventional narrow-bore liquid chromatography-electrospray ionization/mass spectrometric (LC-ESI/MS) system for the analysis of steroids. The limits of detection (LODs) for oxime derivatized steroids, expressed as concentrations, were slightly higher with the HPLC-Chip/MS system (50-300 pM) using an injection volume of 0.5 μL than with the conventional LC-ESI/MS (10-150 pM) using an injection volume of 40 μL. However, when the LODs are expressed as injected amounts, the sensitivity of the HPLC-Chip/MS system was about 50 times higher than with the conventional LC-ESI/MS system. The results indicate that the use of HPLC-Chip/MS system is clearly advantageous only in the analysis of low-volume samples. Both methods showed good linearity and good quantitative and chromatographic repeatability. In addition to the instrument comparisons with oxime derivatized steroids, the feasibility of the HPLC-Chip/MS system in the analysis of non-derivatized and oxime derivatized steroids was compared. The HPLC-Chip/MS method developed for non-derivatized steroids was also applied to the quantitative analysis of 15 mouse plasma samples.

  15. Trends in High Performance Liquid Chromatography for Cultural Heritage.

    Science.gov (United States)

    Degano, Ilaria; La Nasa, Jacopo

    2016-04-01

    The separation, detection and quantitation of specific species contained in a sample in the field of Cultural Heritage requires selective, sensitive and reliable methods. Procedures based on liquid chromatography fulfil these requirements and offer a wide range of applicability in terms of analyte types and concentration range. The main applications of High Performance Liquid Chromatography in this field are related to the separation and detection of dyestuffs in archaeological materials and paint samples by reversed-phase liquid chromatography with suitable detectors. The relevant literature will be revised, with particular attention to sample treatment strategies and future developments. Reversed phase chromatography has also recently gained increasing importance in the analysis of lipid binders and lipid materials in archaeological residues: the main advantages and disadvantages of the new approaches will be discussed. Finally, the main applications of ion chromatography and size exclusion chromatography in the field of Cultural Heritage will be revised in this chapter.

  16. Plasma lipid analysis by hydrophilic interaction liquid chromatography coupled with electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Sonomura, Kazuhiro; Kudoh, Shinobu; Sato, Taka-Aki; Matsuda, Fumihiko

    2015-06-01

    A novel method for the analysis of endogenous lipids and related compounds was developed employing hydrophilic interaction liquid chromatography with electrospray ionization tandem mass spectrometry. A hydrophilic interaction liquid chromatography with carbamoyl stationary phase achieved clear separation of phosphatidylcholine, lysophosphatidylcholine, sphingomyelin, ceramide, and mono-hexsosyl ceramide groups with good peak area repeatability (RSD% 0.99). The established method was applied to human plasma assays and a total of 117 endogenous lipids were successfully detected and reproducibly identified. In addition, we investigated the simultaneous detection of small polar metabolites such as amino and organic acids co-existing in the same biological samples processed in a single analytical run with lipids. Our results show that hydrophilic interaction liquid chromatography is a useful tool for human plasma lipidome analysis and offers more comprehensive metabolome coverage.

  17. High Performance Liquid Chromatography of Vitamin A: A Quantitative Determination.

    Science.gov (United States)

    Bohman, Ove; And Others

    1982-01-01

    Experimental procedures are provided for the quantitative determination of Vitamin A (retinol) in food products by analytical liquid chromatography. Standard addition and calibration curve extraction methods are outlined. (SK)

  18. A generalized theory of chromatography and multistep liquid extraction

    Science.gov (United States)

    Chizhkov, V. P.; Boitsov, V. N.

    2017-03-01

    A generalized theory of chromatography and multistep liquid extraction is developed. The principles of highly efficient processes for fine preparative separation of binary mixture components on a fixed sorbent layer are discussed.

  19. ANALYSIS OF AMINO ACIDS BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

    Directory of Open Access Journals (Sweden)

    Qurat E Noor Baig

    2016-06-01

    Full Text Available Amino acids are the building blocks of proteins and are considered as the key precursors for the formation of hormones and low molecular weight nitrogenous substances with biological importance. Since the analysis of amino acids has been carried out for both qualitative and quantitative purposes with an aim to study their levels in the plasma concentration, the quantitative determination, in particular, also helps in the diagnosis of different diseases associated with their deficiency. This review article deals with the determination of amino acids by chromatographic methods which include ion-exchange chromatography (IEC, high performance liquid chromatography (HPLC, reverse phase-high performance liquid chromatography (RP-HPLC and ultra-performance liquid chromatography (UPLC. The review will also give an idea for the preparation of samples, derivatization methods for the analysis of amino acids (direct and indirect methods and separation of amino acids by high performance liquid chromatographic technique.

  20. Analysis of Tocopherols by High Performance Liquid Chromatography

    OpenAIRE

    Edison, B.

    2009-01-01

    : Gas chromatography is the key technique for organic components and also for tocopherols analysis. High performance liquid chromatography has an important role to take part in applications such as the handling of less usual samples, prevention of degradation of heat sensitive functional groups and for micro preparative purposes. Many approaches for development of improved methods are suggested, especially for reversed phase applications.

  1. Micellar liquid chromatography of terephthalic acid impurities.

    Science.gov (United States)

    Richardson, Ashley E; McPherson, Shakeela D; Fasciano, Jennifer M; Pauls, Richard E; Danielson, Neil D

    2017-03-31

    The production of terephthalic acid (TPA) by oxidation of p-xylene is an important industrial process because high purity TPA is required for the synthesis of polyethylene terephthalate, the primary polymer used to make plastic beverage bottles. Few separation methods have been published that aim to separate TPA from eight major aromatic acid impurities. This work describes a "green" micellar liquid chromatography (MLC) method using a C18 column (100×2.1mm, 3.5μm), an acidic 1% sodium dodecyl sulfate (SDS) mobile phase, and a simple step flow rate gradient to separate TPA and eight impurities in less than 20min. The resulting chromatogram shows excellent peak shape and baseline resolution of all nine acids, in which there are two sets of isomers. Partition coefficients and equilibrium constants have been calculated for the two sets of isomers by plotting the reciprocal of the retention factor versus micelle concentration. Quantitation of the nine analytes in an actual industrial TPA sample is possible. Limits of detection for all nine acids range from 0.180 to 1.53ppm (2.16-19.3 pmoles) and limits of quantitation range from 0.549 to 3.45ppm (6.48-43.0 pmoles). In addition, the method was tested on two other reversed phase C18 columns of similar dimensions and particle diameter from different companies. Neither column showed quite the same peak resolution as the original column, however slight modifications to the mobile phase could improve the separation. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Ion Exchange and Liquid Column Chromatography.

    Science.gov (United States)

    Walton, Harold F.

    1980-01-01

    Emphasizes recent advances in principles and methodology in ion exchange and chromatography. Two tables list representative examples for inorganic ions and organic compounds. Cites 544 references. (CS)

  3. High-Performance Liquid Chromatography: An Overview

    OpenAIRE

    Tandia N; Singh SK1; Kumar N; Singh S

    2013-01-01

    Chromatography is considered extremely powerful separation technique for variety of samples. Thecommon feature of all these techniques is that the different components in a sample mixture aredistributed between two phases, one of which remains stationary while the other the mobile phase, runsthrough the interstices or over the surface of the fixed phase. The movement of the mobile phase resultsin differential migration of the sample components. High performance thin layer chromatography is an...

  4. Analysis of Tocopherols by High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    B. Edison

    2009-01-01

    Full Text Available : Gas chromatography is the key technique for organic components and also for tocopherols analysis. High performance liquid chromatography has an important role to take part in applications such as the handling of less usual samples, prevention of degradation of heat sensitive functional groups and for micro preparative purposes. Many approaches for development of improved methods are suggested, especially for reversed phase applications.

  5. Performance of the same column in supercritical fluid chromatography and in liquid chromatography.

    Science.gov (United States)

    Lambert, Nándor; Felinger, Attila

    2015-08-28

    We have studied the chromatographic behavior of the homologous series of alkylbenzenes (ranging from octylbenzene to octadecylbenzene) on the same C18 reversed-phase column in supercritical fluid chromatography (SFC) and reversed phase liquid chromatography (RPLC) at various experimental conditions, such as different eluent compositions, flow-rates, and mobile phase densities. The first and the second moments of the peaks were used to estimate the overall mass-transfer processes in both chromatographic modes using the stochastic model of chromatography. The results confirm that in SFC - as the density of the mobile phase is influenced by the flow-rate - there is a broader variation of mass-transfer properties than in liquid chromatography. As expected, the optimum mobile phase velocity is higher in SFC, but there is no real difference in the minimum value of plate height, i.e. in the optimum efficiency.

  6. Liquid Chromatography Applied to Space System

    Science.gov (United States)

    Poinot, Pauline; Chazalnoel, Pascale; Geffroy, Claude; Sternberg, Robert; Carbonnier, Benjamin

    Searching for signs of past or present life in our Solar System is a real challenge that stirs up the curiosity of scientists. Until now, in situ instrumentation was designed to detect and determine concentrations of a wide number of organic biomarkers. The relevant method which was and still is employed in missions dedicated to the quest of life (from Viking to ExoMars) corresponds to the pyrolysis-GC-MS. Along the missions, this approach has been significantly improved in terms of extraction efficiency and detection with the use of chemical derivative agents (e.g. MTBSTFA, DMF-DMA, TMAH…), and in terms of analysis sensitivity and resolution with the development of in situ high-resolution mass spectrometer (e.g. TOF-MS). Thanks to such an approach, organic compounds such as amino acids, sugars, tholins or polycyclic aromatic hydrocarbons (PAHs) were expected to be found. However, while there’s a consensus that the GC-MS of Viking, Huygens, MSL and MOMA space missions worked the way they had been designed to, pyrolysis is much more in debate (Glavin et al. 2001; Navarro-González et al. 2006). Indeed, (1) it is thought to remove low levels of organics, (2) water and CO2 could interfere with the detection of likely organic pyrolysis products, and (3) only low to mid-molecular weight organic molecules can be detected by this technique. As a result, researchers are now focusing on other in situ techniques which are no longer based on the volatility of the organic matter, but on the liquid phase extraction and analysis. In this line, micro-fluidic systems involving sandwich and/or competitive immunoassays (e.g. LMC, SOLID; Parro et al. 2005; Sims et al. 2012), micro-chip capillary electrophoreses (e.g. MOA; Bada et al. 2008), or nanopore-based analysis (e.g. BOLD; Schulze-Makuch et al. 2012) have been conceived for in situ analysis. Thanks to such approaches, molecular biological polymers (polysaccharides, polypeptides, polynucleotides, phospholipids, glycolipids

  7. [Simultaneous determination of three antioxidants BHA, BHT and TBHQ in food by liquid chromatography and gas chromatography].

    Science.gov (United States)

    Yang, Jie; Fang, Congrong; Yang, Dajin

    2013-01-01

    To develop a method for determining 3 kinds of antioxidants in food in same time with HPLC and GC. Firstly, extracted fat with petroleum ether, then extracted antioxidants with 13 ml methnol, centrifuged, repeated the above procedure twice, combined the extracts, next evaporated to 5 ml, constanted volume to 10 ml, then kepted in freezer (- 1h), lastly, the supernatant injected into high performance liquid chromatography (HPLC) and Gas chromatography (GC) which had been optimized condition. The limits of quantitation for BHA,BHT and TBHQ were 0.002, 0.010 and 0.002g/kg respectively in HPLC, The limits of quantitation for BHA, BHT and TBHQ were 0.003, 0.002 and 0.005 g/kg respectively in GC, The mean recoveries at the two spiked levels were 82.8% - 109.0%. There were no significant difference between HPLC and GC. The method can be used to determine the antioxidants in food accurately and sensitively, the comparative results are constant between liquid and gas chromatography.

  8. Analysis of ganciclovir and its related substances using high performance liquid chromatography and liquid chromatography-mass spectrometry methods

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    Objective High performance liquid chromatography(HPLC)and liquid chromatography-mass spectrometry(LC/MS)methods were developed for the determination of ganciclovir and its related substances.Methods A Hypersil ODS2 column(4.6 mm×250 mm,5 μm)was used with a mobile phase of 0.02 M potassium dihydrogen phosphate buffer(pH 6.0)-methanol(92∶8)at a flow rate of 1.0 mL/min,and UV detector set at 254 nm was used for monitoring the eluents.Results The method was simple,rapid,selective and capable of separating all r...

  9. Monitoring stevioside in soju by high-performance liquid chromatography and liquid chromatography/mass spectrometry.

    Science.gov (United States)

    Ni, Fan; Ammann, Jeffrey; Mabud, Abdul

    2007-01-01

    A method using high-performance liquid chromatography (HPLC) with UV absorption detection was developed to monitor stevioside in soju, a distilled spirits product that is commercially available. The method uses a single-step dilution for sample preparation. It completely eliminates the time-consuming process of solid-phase extraction. A method using HPLC/mass spectrometry was optimized to confirm the identities of stevioside and other related impurities, including rebaudioside A, rebaudioside C, and dulcoside. The method was validated. The validation parameters included range (10.1-1007.3 ppm), precision, linearity, accuracy, robustness, system suitability, and intermediate precision. Stevioside standard solutions at 6 concentration levels were prepared for the validation work, including the tests for precision, linearity, and accuracy. The solutions were prepared in triplicate for each concentration. The relative standard deviation for the precision test was 0.999. The average recovery ranged from 95.7 to 101.1% for the soju samples spiked with stevioside standard. The detection limit for stevioside was estimated at 75 ppb. The method was used to screen several soju samples; no detectable stevioside was found in the samples.

  10. Liquid chromatography and liquid chromatography-mass spectrometry analysis of donepezil degradation products

    Directory of Open Access Journals (Sweden)

    Mladenović Aleksandar R.

    2015-01-01

    Full Text Available This study describes the investigation of degradation products of donepezil (DP using stability indicating RP-HPLC method for determination of donepezil, which is a centrally acting reversible acetylcholinesterase inhibitor. In order to investigate the stability of drug and formed degradation products, a forced degradation study of drug sample and finished product under different forced degradation conditions has been conducted. Donepezil hydrochloride and donepezil tablets were subjected to stress degradation conditions recommended by International Conference on Harmonization (ICH. Donepezil hydrochloride solutions were subjected to acid and alkali hydrolysis, chemical oxidation and thermal degradation. Significant degradation was observed under alkali hydrolysis and oxidative degradation conditions. Additional degradation products were observed under the conditions of oxidative degradation. The degradation products observed during forced degradation studies were monitored using the high performance liquid chromatography (HPLC method developed. The parent method was modified in order to obtain LC-MS compatible method which was used to identify the degradation products from forced degradation samples using high resolution mass spectrometry. The mass spectrum provided the precise mass from which derived molecular formula of drug substance and degradation products formed and proved the specificity of the method unambiguously. [Projekat Ministarstva nauke Republike Srbije, br. 172013

  11. Towards early detection of the hydrolytic degradation of poly(bisphenol A)carbonate by hyphenated liquid chromatography and comprehensive two-dimensional liquid chromatography

    NARCIS (Netherlands)

    Coulier, L.; Kaal, E.R.; Hankemeier, Th.

    2006-01-01

    The hydrolytic degradation of poly(bisphenol A)carbonate (PC) has been characterized by various liquid chromatography techniques. Size exclusion chromatography (SEC) showed a significant decrease in molecular mass as a result of hydrolytic degradation, while 'liquid chromatography at critical

  12. Towards early detection of the hydrolytic degradation of poly(bisphenol A)carbonate by hyphenated liquid chromatography and comprehensive two-dimensional liquid chromatography

    NARCIS (Netherlands)

    Coulier, L.; Kaal, E.R.; Hankemeier, Th.

    2006-01-01

    The hydrolytic degradation of poly(bisphenol A)carbonate (PC) has been characterized by various liquid chromatography techniques. Size exclusion chromatography (SEC) showed a significant decrease in molecular mass as a result of hydrolytic degradation, while 'liquid chromatography at critical condit

  13. Mallow carotenoids determined by high-performance liquid chromatography

    Science.gov (United States)

    Mallow (corchorus olitorius) is a green vegetable, which is widely consumed either fresh or dry by Middle East population. This study was carried out to determine the contents of major carotenoids quantitatively in mallow, by using a High Performance Liquid Chromatography (HPLC) equipped with a Bis...

  14. Determination of Caffeine in Beverages by High Performance Liquid Chromatography.

    Science.gov (United States)

    DiNunzio, James E.

    1985-01-01

    Describes the equipment, procedures, and results for the determination of caffeine in beverages by high performance liquid chromatography. The method is simple, fast, accurate, and, because sample preparation is minimal, it is well suited for use in a teaching laboratory. (JN)

  15. Multichannel Detection in High-Performance Liquid Chromatography.

    Science.gov (United States)

    Miller, James C.; And Others

    1982-01-01

    A linear photodiode array is used as the photodetector element in a new ultraviolet-visible detection system for high-performance liquid chromatography (HPLC). Using a computer network, the system processes eight different chromatographic signals simultaneously in real-time and acquires spectra manually/automatically. Applications in fast HPLC…

  16. High-Performance Liquid Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Vestal, Marvin L.

    1984-01-01

    Reviews techniques for online coupling of high-performance liquid chromatography with mass spectrometry, emphasizing those suitable for application to nonvolatile samples. Also summarizes the present status, strengths, and weaknesses of various techniques and discusses potential applications of recently developed techniques for combined liquid…

  17. Ultra high performance liquid chromatography of seized drugs

    NARCIS (Netherlands)

    Lurie, I.S.

    2010-01-01

    The primary goal of this thesis is to investigate the use of ultra high performance liquid chromatography (UHPLC) for the analysis of seized drugs. This goal was largely achieved and significant progress was made in achieving improved separation and detection of drugs of forensic interest.

  18. High-performance liquid chromatography with packed microchips

    OpenAIRE

    Ehlert, Steffen

    2011-01-01

    This work is explaining the importance of generating a densely packed chromatographic bed to achieve optimum separation efficiency in miniaturized liquid chromatography. The reduction of peak dispersion and enhancement of separation efficiency is the important problem in micro- and nano-separation that is to be solved to generate highly efficient chromatographic systems that can exploit all advantages of miniaturization. Therefore...

  19. Characterisation of cholera toxin by liquid chromatography - Electrospray mass spectrometry

    NARCIS (Netherlands)

    Baar, B.L.M. van; Hulst, A.G.; Wils, E.R.J.

    1999-01-01

    Cholera toxin, one of the toxins that may be generated by various strains of the bacterium Vibrio cholerae, can be considered as a substance possibly used in biological warfare. The possibilities of characterising the toxin by liquid chromatography electrospray mass spectrometry (LC-ES-MS) were inve

  20. Characterisation of cholera toxin by liquid chromatography - Electrospray mass spectrometry

    NARCIS (Netherlands)

    Baar, B.L.M. van; Hulst, A.G.; Wils, E.R.J.

    1999-01-01

    Cholera toxin, one of the toxins that may be generated by various strains of the bacterium Vibrio cholerae, can be considered as a substance possibly used in biological warfare. The possibilities of characterising the toxin by liquid chromatography electrospray mass spectrometry (LC-ES-MS) were

  1. Advancing liquid chromatography- mass spectrometry based technologies for proteome research

    NARCIS (Netherlands)

    Boersema, P.J.

    2010-01-01

    In proteomics, high-tech nano-liquid chromatography (LC) and mass spectrometry (MS) instrumentation is used to routinely sequence proteins at a large scale. In this thesis, several technological developments are described to advance proteomics and their applicability is demonstrated in several diffe

  2. Quantification of Tea Flavonoids by High Performance Liquid Chromatography

    Science.gov (United States)

    Freeman, Jessica D.; Niemeyer, Emily D.

    2008-01-01

    We have developed a laboratory experiment that uses high performance liquid chromatography (HPLC) to quantify flavonoid levels in a variety of commercial teas. Specifically, this experiment analyzes a group of flavonoids known as catechins, plant-derived polyphenolic compounds commonly found in many foods and beverages, including green and black…

  3. Coupling of column liquid chromatography and Fourier transform infrared spectrometry

    NARCIS (Netherlands)

    Somsen, G.W; Gooijer, C; Velthorst, N.H; Brinkman, U.A Th

    1998-01-01

    This paper provides an extensive overview of the literature on the coupling of column liquid chromatography (LC) and Fourier transform infrared spectrometry (FT-IR). Flow-cell-based FT-IR detection and early solvent-elimination interfaces for LC-FT-IR are discussed in brief. A comprehensive descript

  4. Alternative solvents can make preparative liquid chromatography greener

    NARCIS (Netherlands)

    Shen, Y.; Chen, B.; Beek, van T.A.

    2015-01-01

    To make preparative Reversed-Phase High Performance Liquid Chromatography (RP-pHPLC) greener, alternative solvents were considered among others in terms of toxicity, cost, safety, workability, chromatographic selectivity and elution strength. The less toxic solvents ethanol, acetone and ethyl acetat

  5. Challenges in polymer analysis by liquid chromatography

    NARCIS (Netherlands)

    E. Uliyanchenko; S. van der Wal; P.J. Schoenmakers

    2012-01-01

    Synthetic polymers are very important in our daily life. Many valuable properties of polymers are determined by their molecular weight and chemical composition. Liquid chromatographic (LC) techniques are very commonly used for molecular characterisation of polymers. LC analysis of macromolecules is

  6. Analysis of Free Fatty Acids on the Fingertips by High Performance Liquid Chromatography.

    Science.gov (United States)

    1978-12-20

    This investigation studied the efficiency of high performance liquid chromatography in the determination of free fatty acids present on the...utilized to eliminate the microbial contamination. The high performance liquid chromatography provided excellent separation of skin fatty acids for

  7. A Review on Ultra Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Darasanapalli Meenakshi

    2013-06-01

    Full Text Available UPLC is a rising chromatographic separation technique whose packing materials have smaller particle size lesser than 2.5μm which improves the speed, resolution and sensitivity of analysis. When many scientists experienced separation barriers with conventional HPLC, UPLC extended and expanded the utility of chromatography. The main advantage is a reduction of analysis time which also reduces solvent consumption. The analysis time, solvent consumption and analysis cost are very important factor in many analytical laboratories. The time spent for optimizing new methods can also be greatly reduced. This results in many analysis in a day and quick results which is of very importance to the industries and research laboratories. UPLC principle is same as that of HPLC that is based on Van Deemter equation but decrease in particle size has increased efficiency at increased flow rates.

  8. Determination of a Jet Fuel Metal Deactivator by High Performance Liquid Chromatography

    Science.gov (United States)

    1983-06-01

    HIGH PERFORMANCE LIQUID CHROMATOGRAPHY Paul C. Hayes, Jr. Fuels Branch...SUPPLEMENTARY NOTES 19. KEY WORDS (Continue on reverse side if necessary and identify by block number) High Performance Liquid Chromatography absorbance...SYMBOL HPLC High Performance Liquid Chromatography P-4 jet propulsion fuel, wide-boiling range, conforming to MIL-T-5624L MDA metal deactivator,

  9. Determination of Stabiliser Contents in Advanced Gun Propellants by Reverse Phase High Performance Liquid Chromatography

    Science.gov (United States)

    1994-03-01

    HIGH PERFORMANCE LIQUID CHROMATOGRAPHY N"m A.R. TURNER AND A. WHITE...TO biEPROOU.; AND SELL THIS REPORT Determination of Stabiliser Contents in Advanced Gun Propellants by Reverse Phase High Performance Liquid Chromatography A.R...8217/......... .. Availability Cooes Dist Avaiardlo A-i Determination of Stabiliser Contents in Advanced Gun Propellants by Reverse Phase High Performance Liquid Chromatography

  10. Theories to support method development in comprehensive two-dimensional liquid chromatography - A review

    NARCIS (Netherlands)

    Bedani, F.; Schoenmakers, P.J.; Janssen, H.-G.

    2012-01-01

    On-line comprehensive two-dimensional liquid chromatography techniques promise to resolve samples that current one-dimensional liquid chromatography methods cannot adequately deal with. To make full use of the potential of two-dimensional liquid chromatography, optimization is required. Optimization

  11. 21 CFR 862.2260 - High pressure liquid chromatography system for clinical use.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false High pressure liquid chromatography system for... Clinical Laboratory Instruments § 862.2260 High pressure liquid chromatography system for clinical use. (a) Identification. A high pressure liquid chromatography system for clinical use is a device intended to...

  12. 21 CFR 862.2250 - Gas liquid chromatography system for clinical use.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gas liquid chromatography system for clinical use... Instruments § 862.2250 Gas liquid chromatography system for clinical use. (a) Identification. A gas liquid chromatography system for clinical use is a device intended to separate one or more drugs or compounds from...

  13. Determination of chlorobenzenes in textiles by pressurized hot water extraction followed by vortex-assisted liquid-liquid microextraction and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Lu, Yang; Zhu, Yan

    2013-12-06

    A method for quantitative determination of chlorobenzenes in textiles is developed, using pressurized hot water extraction (PHWE), vortex-assisted liquid-liquid microextraction (VALLME) and gas chromatography-mass spectrometry (GC-MS). VALLME serves as a trapping step after PHWE. The extraction conditions are investigated, as well as the quantitative features such as linearity, limits of detection (LODs), limits of quantification (LOQs), repeatabilities and reproducibilities between days. LOQs of 0.018-0.032mg/kg were achieved. The present method provides good repeatabilities (RSDGC-MS is a simple, rapid and environmentally friendly method for determination of chlorobenzenes in textiles.

  14. Optimizing heterosurface adsorbent synthesis for liquid chromatography

    Science.gov (United States)

    Bogoslovskii, S. Yu.; Serdan, A. A.

    2016-03-01

    The structural and geometric parameters of a silica matrix (SM) for the synthesis of heterosurface adsorbents (HAs) are optimized. Modification is performed by shielding the external surfaces of alkyl-modified silica (AS) using human serum albumin and its subsequent crosslinking. The structural and geometric characteristics of the SM, AS, and HA are measured via low-temperature nitrogen adsorption. It is found that the structural characteristics of AS pores with diameters D 9 nm reduces significantly due to adsorption of albumin. It is concluded that silica gel with a maximum pore size distribution close to 5 nm and a minimal proportion of pores with D > 9 nm is optimal for HA synthesis; this allows us to achieve the greatest similarity between the chromatographic retention parameters for HA and AS. The suitability of the synthesized adsorbents for analyzing drugs in biological fluids through direct sample injection is confirmed by chromatography. It was found that the percentage of the protein fraction detected at the outlet of the chromatographic column is 98%.

  15. Preliminary Validation of High Performance Liquid Chromatography Method for Detection of Methyltestosterone Residue in Carp Muscle

    Institute of Scientific and Technical Information of China (English)

    JIANG Jie; LIN Hong; FU Xiaoting; LI Mingming

    2005-01-01

    The use of synthetic anabolic steroid methyltestosterone (MT) as growth promoter is prohibited in China. Validations of analytical methods for MT residue in food and the results obtained have become indispensable. The high performance liquid chromatography (HPLC) method for the detection of MT with liquid-liquid extraction by trichloromethanemethanol in carp muscle tissue was preliminarily validated with reference to the following parameters: recovery (accuracy)at the 1, 5 and 10 mgkg-1 level, between-run and within-run CV values (repeatability, also called relative standard deviation(RSD)) and limit of detection. The recoveries were above 80% and the between-run and within-run CV values below 10%for muscle tissue. The limit of detection was 0.05 mgkg-1.

  16. Standard flow liquid chromatography for shotgun proteomics in bioenergy research.

    Science.gov (United States)

    González Fernández-Niño, Susana M; Smith-Moritz, A Michelle; Chan, Leanne Jade G; Adams, Paul D; Heazlewood, Joshua L; Petzold, Christopher J

    2015-01-01

    Over the past 10 years, the bioenergy field has realized significant achievements that have encouraged many follow on efforts centered on biosynthetic production of fuel-like compounds. Key to the success of these efforts has been transformational developments in feedstock characterization and metabolic engineering of biofuel-producing microbes. Lagging far behind these advancements are analytical methods to characterize and quantify systems of interest to the bioenergy field. In particular, the utilization of proteomics, while valuable for identifying novel enzymes and diagnosing problems associated with biofuel-producing microbes, is limited by a lack of robustness and limited throughput. Nano-flow liquid chromatography coupled to high-mass accuracy, high-resolution mass spectrometers has become the dominant approach for the analysis of complex proteomic samples, yet such assays still require dedicated experts for data acquisition, analysis, and instrument upkeep. The recent adoption of standard flow chromatography (ca. 0.5 mL/min) for targeted proteomics has highlighted the robust nature and increased throughput of this approach for sample analysis. Consequently, we assessed the applicability of standard flow liquid chromatography for shotgun proteomics using samples from Escherichia coli and Arabidopsis thaliana, organisms commonly used as model systems for lignocellulosic biofuels research. Employing 120 min gradients with standard flow chromatography, we were able to routinely identify nearly 800 proteins from E. coli samples; while for samples from Arabidopsis, over 1,000 proteins could be reliably identified. An examination of identified peptides indicated that the method was suitable for reproducible applications in shotgun proteomics. Standard flow liquid chromatography for shotgun proteomics provides a robust approach for the analysis of complex samples. To the best of our knowledge, this study represents the first attempt to validate the standard

  17. Standard flow liquid chromatography for shotgun proteomics in bioenergy research

    Directory of Open Access Journals (Sweden)

    Susana M. González Fernández-Niño

    2015-04-01

    Full Text Available Over the past ten years the bioenergy and biofuels field has realized significant achievements that have encouraged many follow on efforts centered on biosynthetic production of fuel-like compounds. Key to the success of these efforts has been transformational developments in feedstock characterization and metabolic engineering of biofuel-producing microbes. Lagging far behind these advancements are analytical methods to characterize and quantify systems of interest to the bioenergy field. In particular the utilization of proteomics, while valuable for identifying novel enzymes and diagnosing problems associated with biofuel-producing microbes, is limited by a lack of robustness and limited throughput. Nano-flow liquid chromatography coupled to high-mass accuracy, high-resolution mass spectrometers has become the dominant approach for the analysis of complex proteomic samples, yet such assays still require dedicated experts for data acquisition, analysis, and instrument upkeep. The recent adoption of standard flow chromatography (ca. 0.5 mL/min for targeted proteomics has highlighted the robust nature and increased throughput of this approach for sample analysis. Consequently, we assessed the applicability of standard flow liquid chromatography for shotgun proteomics using samples from Escherichia coli and Arabidopsis thaliana, organisms commonly used as model systems for lignocellulosic biofuels research. Employing 120 minute gradients with standard flow chromatography we were able to routinely identify nearly 800 proteins from E. coli samples, while for samples from Arabidopsis over 1,000 proteins could be reliably identified. An examination of identified peptides indicated that the method was suitable for reproducible applications in shotgun proteomics. Standard flow liquid chromatography for shotgun proteomics provides a robust approach for the analysis of complex samples. To the best of our knowledge this study represents the first attempt

  18. Nano-liquid chromatography applied to enantiomers separation.

    Science.gov (United States)

    Fanali, Salvatore

    2017-02-24

    This paper presents the state of the art concerning the separation of chiral compounds by means of nano-liquid chromatography (nano-LC). The enantiomers' separation and determination are a subject of fundamental importance in various application fields such as pharmaceutical industry, biomedicine, food, agrochemical etc. Nano-LC is a miniaturized chromatographic technique offering some advantages over conventional ones such as low consumption of mobile phase, sample volume and amount of chiral stationary phase, reduced costs etc. This is reported in the first part of the paper illustrating the features of the nano-LC. In addition, chiral resolution methods are briefly illustrated. Some chiral selectors, used in high-performance liquid chromatography have also been applied in nano-LC including cyclodextrins, glycopeptide antibiotics, modified polysaccharides etc. This is discussed in the second part of the review. Finally some examples of the applications available in literature are reported.

  19. DETERMINATION OF GAMMA - AMINOBUTYRIC ACID BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY

    Directory of Open Access Journals (Sweden)

    D. Qujeq

    1998-08-01

    Full Text Available Gamma-aminobutyric acid is the main inhibitory amino acid neurotransmitter in several areas of the brain. Measurement of gamma-aminobutyric acid in the brain will help elucidate its metabolic rote and diagnostic value. The liquid chromatography (LC system consisted of a delivery pump. Male rats (150-250g were used in this study. The brain was rapidly removed from decapitated animals. Trie chromatograms showed satisfactory resolution and symmetrical peak shapes, both with the standard and tissue extracts. the retention lime was 4.60 min. it was constant in repeated analyses and exactly the same for the standard and tissue samples.

  20. Temperature-Modulated Array High-Performance Liquid Chromatography

    OpenAIRE

    Premstaller, Andreas; Xiao, Wenzhong; Oberacher, Herbert; O'Keefe, Matthew; Stern, David; Willis, Thomas; Huber, Christian G.; Peter J. Oefner

    2001-01-01

    Using novel monolithic poly(styrene-divinylbenzene) capillary columns with an internal diameter of 0.2 mm, we demonstrate for the first time the feasibility of constructing high-performance liquid chromatography arrays for the detection of mutations by heteroduplex analysis under partially denaturing conditions. In one embodiment, such an array can be used to analyze one sample simultaneously at different temperatures to maximize the detection of mutations in DNA fragments containing multiple...

  1. Determination of serotonin released from coffee wax by liquid chromatography.

    Science.gov (United States)

    Kele, M; Ohmacht, R

    1996-04-12

    A simple hydrolysis and extraction method was developed for the release of serotonin (5-hydroxytryptamine) from a coffee wax sample obtained from decaffeination of coffee beans. The recoverable amount of serotonin was determined by reversed-phase high-performance liquid chromatography with gradient elution and UV detection, using the standard addition method. Different type of basic deactivated chromatographic columns were used for the separation.

  2. Determination of aminocresol isomers by high-speed liquid chromatography.

    Science.gov (United States)

    Sakurai, H; Kito, M

    Aminocresol isomers (4-hydroxy-m-toluidine [II], 3-hydroxy-p-toluidine [II], 2-hydroxy-p-toluidine [III]) and p-aminophenol have been separated and determined by a high-speed liquid Chromatographie method. Since this method is applicable in aqueous media, it was used to investigate the suitability of a haemin-cysteine system as a model for the cytochrome P-450 mono-oxygenase system, by determination of the [I], [II], [III] and p-aminophenol formed.

  3. Quantitation of antioxidants in water samples using ionic liquid dispersive liquid-liquid microextraction followed by high-performance liquid chromatography-ultraviolet detection.

    Science.gov (United States)

    Sobhi, Hamid Reza; Kashtiaray, Amir; Farahani, Hadi; Farahani, Mohammad Reza

    2011-01-01

    A simple and efficient method, ionic liquid-based dispersive liquid-liquid microextraction combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV), has been applied for the extraction and determination of some antioxidants (Irganox 1010, Irganox 1076 and Irgafos 168) in water samples. The microextraction efficiency factors were investigated and optimized: 1-hexyl-3-methylimidazolium hexafluorophosphate [C(6)MIM][PF(6)] (0.06 g) as extracting solvent, methanol (0.5 mL) as disperser solvent without salt addition. Under the selected conditions, enrichment factors up to 48-fold, limits of detection (LODs) of 5.0-10.0 ng/mL and dynamic linear ranges of 25-1500 ng/mL were obtained. A reasonable repeatability (RSD≤11.8%, n=5) with satisfactory linearity (r(2)≥0.9954) of the results illustrated a good performance of the presented method. The accuracy of the method was tested by the relative recovery experiments on spiked samples, with results ranging from 85 to 118%. Finally, the method was successfully applied for determination of the analytes in several real water samples. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Purification of proteins specifically binding human endogenous retrovirus K long terminal repeat by affinity elution chromatography.

    Science.gov (United States)

    Trubetskoy, D O; Zavalova, L L; Akopov, S B; Nikolaev, L G

    2002-11-01

    A novel affinity elution procedure for purification of DNA-binding proteins was developed and employed to purify to near homogeneity the proteins recognizing a 21 base pair sequence within the long terminal repeat of human endogenous retroviruses K. The approach involves loading the initial protein mixture on a heparin-agarose column and elution of protein(s) of interest with a solution of double-stranded oligonucleotide containing binding sites of the protein(s). The affinity elution has several advantages over conventional DNA-affinity chromatography: (i) it is easier and faster, permitting to isolate proteins in a 1 day-one stage procedure; (ii) yield of a target protein is severalfold higher than that in DNA-affinity chromatography; (iii) it is not necessary to prepare a special affinity support for each factor to be isolated. Theaffinity elution could be a useful alternative to conventional DNA-affinity chromatography.

  5. Thermal expansion pump for capillary high-performance liquid chromatography.

    Science.gov (United States)

    Tao, Qian; Wu, Qian; Zhang, Xiangmin

    2010-02-01

    A thermal expansion pump (TEP) based on a principle of liquid thermal expansion for capillary high-performance liquid chromatography has been developed. The novel pump is capable of generating a continuous flow at high pressure for constant and stable delivery of binary solvents from nanoliters to microliters per minute without splitting. Theoretical equations for controlling fluidic output of this pump have been established and validated by a series of experiments. Factors affecting flow rate, such as density discrepancy, liquid compressibility, and mass loss in output, were taken into account. An assembly of the pump system employing two groups of thermal expansion pumps (TEPs) working in turns were fabricated, and a controlling strategy for the pump system to maintain a continuous delivery without pressure fluctuation even at switching points was also developed. Both isocratic and gradients of binary solvent delivery by the TEPs were performed. Reproducibility and standard deviation at different flow rates were determined. A capillary high-performance liquid chromatography (micro-HPLC) system consisting of the TEPs, an injection valve, a homemade packed capillary column (20 cm x 100 microm i.d. with 5 microm C18), and a laser-induced fluorescence detector was set up, and sample separations were carried out. Results of RSD = 4% for flow and RSD = 2% for retention times at 500 nL/min were achieved. Such a pump system has almost no moving parts except for the solvent switches. Its overall costs of manufacture and running are very low. It is proven that the TEPs system has great potential and competitive capabilities in capillary liquid chromatography.

  6. Liquid chromatography-mass spectroscopy and liquid chromatography-ultraviolet/visible photodiode array analysis of selected colchicum species.

    Science.gov (United States)

    Gharaibeh, Ahmad A; Al-Serini, Ala'a; Qasaymeh, Rana M; Ma'aya'h, Amani S; Tawaha, Khaled; El-Elimat, Tamam; Alali, Feras Q

    2012-01-01

    An in-house strategy to dereplicate colchicinoid alkaloids was recently developed by our team. It aimed at quickly identifying Colchicum constituents using LC-MS (liquid chromatography-mass spectroscopy) and LC-UV/Vis PDA (liquid chromatography-ultraviolet/ visible photodiode array) techniques. In this project, our goal was to validate the developed method through analysing the alkaloid-rich fractions of three Colchicum species that had been previously studied phytochemically using the traditional bioactivity-guided fractionation methodology. The analysed species were Colchicum tauri Siehe ex Stefanoff, Colchicum stevenii Kunth, and Colchicum tunicatum Feinbr., all belonging to the family Colchicaceae. In addition to identifying the compounds previously isolated and characterized by the traditional methodology, the new strategy succeeded in tentatively identifying a set of known compounds, but new to the species.

  7. HPLC separation and GC-MS identification of the polar components of coal liquids. [High pressure liquid chromatography, gas chromatography-mass spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Satoh, M.; Tanabe, K.; Uchino, H.; Yokoyama, S.; Sanada, Y.

    1984-01-01

    The polar components in the 200-400 C fraction of Akabira coal liquids were separated by high pressure liquid chromatography using an amine-based column. By varying the CHCl/sub 3/ concentration in the solvent, basic, neutral and acid fractions were obtained. These were then investigated separately using infrared spectroscopy, flame ionization detection-gas chromatography and gas chromatography-mass spectroscopy. The basic fraction contained alkyltetrahydroquinolines, the neutral fraction, alkylphenols and alkylcarbazoles; and the acid fraction, alkylphenols. 15 references.

  8. Development and comparison of two dispersive liquid-liquid microextraction techniques coupled to high performance liquid chromatography for the rapid analysis of bisphenol A in edible oils.

    Science.gov (United States)

    Liu, Shuhui; Xie, Qilong; Chen, Jie; Sun, Janzhi; He, Hui; Zhang, Xiaoke

    2013-06-21

    In this study, two novel sample extraction methods for the analysis of bisphenol A (BPA) in edible oils were developed by using liquid-liquid extraction followed by a dispersive liquid-liquid microextraction (LLE-DLLME) and reversed-phase dispersive liquid-liquid microextraction (RP-DLLME). RP-DLLME showed a superior characteristic over LLE-DLLME and other previously reported procedures because of its easy operation, short extraction time, high sensitivity, low organic solvent consumption and waste generation. The optimized extraction conditions of RP-DLLME for 1.0 g of edible oil diluted in 4 mL of n-hexane were: extractant, 100 μL 0.2 M sodium hydroxide solution (80% methanol, v/v); extraction time, 1 min; centrifugation, 3 min. The determination of BPA was carried out by high performance liquid chromatography coupled with a DAD detector. The method offered excellent linearity over a range of 0.010-0.5 μg g(-1) with a correlation coefficient of r>0.997. Intra-day and inter-day repeatability values expressed as relative standard deviation were 1.9% and 5.9%, respectively. The quantitation limit and detection limit were 6.3 and 2.5 ng g(-1). The target analyte was detected in 5 out of 16 edible oil samples. The recovery rates in real samples ranged from 89.5 to 99.7%.

  9. Pressurized nano-liquid-junction interface for coupling capillary electrochromatography and nano-liquid chromatography with mass spectrometry.

    Science.gov (United States)

    D'Orazio, Giovanni; Fanali, Salvatore

    2013-11-22

    A new nano-liquid-junction interface for coupling both capillary electrochromatography (CEC) or nano-liquid chromatography (nano-LC) with mass spectrometry (MS) was studied. The interface was a small T piece of polymeric material where capillary column and tip capillary were positioned at 180° while the third exit (at 90°) was occupied by a capillary delivering a liquid-assisting spray ionization for CEC experiments or by the electrode for the high voltage spray for nano-LC. Experiments were carried out analyzing mixtures of some organophosphorus pesticides (OPPs) or anti-inflammatory and related acidic drugs with MS detection in positive or negative ion mode, respectively. Analyzed OPPs compounds were baseline resolved utilizing the novel interface in both nano-LC and CEC obtaining good sensitivity and repeatability. For CEC-MS, the limits of detection ranged between 0.03 and 6.80 μg/mL and the intra-day repeatability was RSD interface was easy to handle and good reproducibility, between 2.5 and 3.5% for the retention time and interface was installed by two different analysts. Furthermore, it could be used for both CEC and nano-LC.

  10. Determination of plastic additives in packaging by liquid chromatography coupled to high resolution mass spectrometry.

    Science.gov (United States)

    Moreta, Cristina; Tena, María-Teresa

    2015-10-02

    A simple and sensitive analytical method for the determination of several plastic additives in multilayer packaging based on solid-liquid extraction (SLE) and ultra-high performance liquid chromatography (UHPLC) coupled to variable wavelength (VWD) and time of flight mass spectrometry (TOF-MS) detectors is presented. The proposed method allows the simultaneous determination of fourteen additives belonging to different families such as antioxidants, slip agents and light stabilizers, as well as two oxidation products in only 9min. The developed method was validated in terms of linearity, matrix effect error, detection and quantification limits, repeatability and intermediate precision. The instrumental method showed satisfactory repeatability and intermediate precision at concentrations closed to LOQ with RSDs less than 7 and 20%, respectively, and LODs until 5000 times more sensitive than other GC-FID and HPLC-VWD methods previously reported. Also, focused ultrasound solid-liquid extraction (FUSLE) was optimized and evaluated to extract plastic additives from packaging. Extraction results obtained by FUSLE and SLE were compared to those obtained by pressurized liquid extraction (PLE). All extraction methods showed excellent extraction efficiency for slip agents, however quantitative recovery of all analytes was achieved only by SLE with just 5ml of hexane for 10h. Finally, the selected method was applied to the analysis of packaging samples where erucamide, Irgafos 168, oxidized Irgafos 168, Irganox 1076 and Irganox 1010 were detected and quantified. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Ionic Liquids as Mobile Phase Additives for Separation of Nucleotides in High-Performance Liquid Chromatography

    Institute of Scientific and Technical Information of China (English)

    ZHANG,Wen-Zhu(张文珠); HE,Li-Jun(何丽君); LIU,Xia(刘霞); JIANG,Sheng-Xiang(蒋生祥)

    2004-01-01

    Ionic liquids are a type of salts that are liquid at low temperature (< 100 ℃). Because of their some special properties, they have been widely used as new "green solvents" for many chemical reactions and liquid-liquid extraction in the past several years. In this paper, a new method for the separation of nucleotides is developed and the essential feature of the method is that 1-alkyl-3-methylimidazolium salts are used as mobile phase additives, resulting in a baseline separation of nucleotides without need of gradient elution and need of organic solvent addition as currently used in RP-HPLC. This study shows the potential application of ionic liquids as mobile phase additives in reversed-phase liquid chromatography.

  12. Mass transfer mechanism in chiral reversed phase liquid chromatography.

    Science.gov (United States)

    Gritti, Fabrice; Guiochon, Georges

    2014-03-01

    The mechanism of mass transfer in chiral chromatography was investigated using an experimental protocol already applied in RPLC and HILIC chromatography. The different contributions to the reduced height equivalent to a theoretical plate (HETP) include the longitudinal diffusion HETP term, the solid-liquid mass transfer resistance HETP term, the short-range eddy dispersion HETP term, and the long-range eddy dispersion HETP term. Their accurate measurement permits the determination of the adsorption rate constant kads of trans-stilbene enantiomers on a column packed with Lux 5 μm Cellulose-1 particles. The experimental results demonstrate that the number of adsorption-desorption steps per unit time of chiral compounds on polysaccharide-based chiral stationary phases is four orders of magnitude smaller than that of achiral compounds.

  13. Modeling of closed-loop recycling liquid-liquid chromatography: Analytical solutions and model analysis.

    Science.gov (United States)

    Kostanyan, Artak E

    2015-08-07

    In closed-loop recycling (CLR) chromatography, the effluent from the outlet of a column is directly returned into the column through the sample feed line and continuously recycled until the required separation is reached. To select optimal operating conditions for the separation of a given feed mixture, an appropriate mathematical description of the process is required. This work is concerned with the analysis of models for the CLR separations. Due to the effect of counteracting mechanisms on separation of solutes, analytical solutions of the models could be helpful to understand and optimize chromatographic processes. The objective of this work was to develop analytical expressions to describe the CLR counter-current (liquid-liquid) chromatography (CCC). The equilibrium dispersion and cell models were used to describe the transport and separation of solutes inside a CLR CCC column. The Laplace transformation is applied to solve the model equations. Several possible CLR chromatography methods for the binary and complex mixture separations are simulated.

  14. MEMS Liquid and Gas Chromatography for Miniaturized Planetary In Situ Instruments

    Science.gov (United States)

    Kidd, R. D.; Bae, B.; Willis, P. A.; Noell, A. C.; Scianmarello, N.; Tai, Y.-C.

    2016-10-01

    Micro-Electro-Mechanical Systems (MEMS) technology to reduce the size, mass and power of the three classical chromatographic technologies: gas chromatography (GC), capillary electrophoresis (CE) and high performance liquid chromatography (HPLC).

  15. Purification of pituitary autoantigen by column liquid chromatography and chromatofocusing.

    Science.gov (United States)

    Gut, Paweł; Fischbach, Jakub; Ziemnicka, Katarzyna; Bączyk, Maciej; Baszko-Błaszyk, Daria; Wrotkowska, Elżbieta; Ruchała, Marek

    2014-01-01

    Pituitary autoantibodies can be determined both in patients with pituitary disease as well as patients with autoimmune endocrine diseases. The purpose of the study was to isolate and purify pituitary autoantigen using sera of patients and the microsomal fraction of the pituitary. To isolate a pituitary autoantigen, patient sera were used, which showed a strong immune response to pituitary antigens. Pituitary microsomal fractions were prepared from pituitary tissue homogenates. In the study, sera of patients with pituitary disease, Addison and Graves' disease were used. The initial stages were carried out by affinity chromatography on CN -Br sepharose column whereas purification was continued by column liquid chromatography on AcA54 Ultrogel. Chromatofocusing was performed by Polybuffer exchanger PBE 94. (125)I-labeled pituitary antigens after isolation appeared in column chromatography in three peaks. The first peak contained 50-70 kDa proteins, the second peak - 17 to 22 kDa proteins and the third peak contains (125)-iodides. Three fractions obtained from filtration on Ultrogel were separated in a polyacrylamide gel. In the first peak two bands 67 and 55 kDa appeared. The second peak contained low molecular weight substances, and the third peak contained (125)I. The first peak from Ultrogel was isolated by chromatofocusing - the first peak with pH 5.9 and the second one with pH 4.9. Isolation and purification of pituitary autoantigen with the use of column liquid chromatography and chromatofocusing resulted in obtainment of two antigenic proteins of specific gravity of 67 and 55 kDa.

  16. Quantification of tryptophan in plasma by high performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Renata Romanholi Pinhati

    2012-01-01

    Full Text Available A simple, rapid and selective method using high-performance liquid chromatography with ultraviolet detection (267 nm was applied for the determination of tryptophan in plasma. Separation was carried out on a C18 column (150 x 4.6 mm internal diameter in 6 min. The mobile phase consisted of 5 mM the sodium acetate and acetonitrile (92:8, v/v. The method was shown to be precise and accurate, and good recovery of analyte was achieved, characterizing the method as efficient and reliable for use in laboratory analysis.

  17. A novel ionic liquids grafted polysiloxane for capillary gas chromatography

    Institute of Scientific and Technical Information of China (English)

    Qing Quan Wei; Mei Ling Qi; Ruo Nong Fu

    2009-01-01

    A new ionic liquids grafted polysiloxane used as stationary phase for capillary gas chromatography(CGC)is described.The stationary phase of 1-vinyl-3-hexylimidazolium hexafluorophosphate anchored to polysiloxane(PMHS-[VHIm][PF6])was synthesized,characterized and coated onto capillary columns by static coating.The results show that the present stationary phase exhibits a very good chromatographic resolution and selectivity for Grob test mixture and alcohols with baseline resolution and symmetry peaks.The present work suggests that novel stationary phase has a great potential for further development and application.

  18. Gas-liquid chromatography in lunar organic analysis.

    Science.gov (United States)

    Gehrke, C. W.

    1972-01-01

    Gas-liquid chromatography (GLC) is a powerful and sensitive method for the separation and detection of organic compounds at nanogram levels. The primary requirement for successful analyses is that the compounds of interest must be volatile under the chromatographic conditions employed. Nonvolatile organic compounds must be converted to volatile derivatives prior to analysis. The derivatives of choice must be both amenable to chromatographic separation and be relatively stable. The condition of volatility necessitates the development of efficient derivatization reactions for important groups of compounds as amino acids, carbohydrates, nucleosides, etc. Trimethylsilylation and trifluoroacetylation represent specific areas of recent prominence. Some relevant practical aspects of GLC are discussed.

  19. Determination of Selected Colored Smokes on Glass Fiber Discs by High Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    1991-05-01

    High Performance Liquid Chromatography (HPLC) 12. PERSONAL AUTHOR(S) F F_ n.ipl’prifl. Alan R...GROUP SUB-GROUP High Performance Liquid Chromatography (HPLC), Analytical IMethod, 1,4-diamino-2,3-dihydroanthraquinone, 2-(2 - _ quinolinyl)-1,3...weights, low vapor pressures and low thermal stability. High performance liquid chromatography (HPLC) appears to be the analytical method of choice

  20. Determination of Stereoisomers of Epalrestat by Liquid Chromatography

    Institute of Scientific and Technical Information of China (English)

    齐美玲; 王鹏; 杨建军

    2004-01-01

    An isocratic reversed-phase liquid chromatographic (LC) method is described for the determination of epalrestat and its three stereoisomers (degradation impurities) in drug substance. The LC separation system consisted of a Hypersil C18 column (250 mm×4.6 mm, 5 μm) with a mobile phase comprising methanol, acetonitrile and water (volume ratio 60∶1∶50, pH 4.5) delivered at a flow rate of 1.6 mL/min and UV detection at 280 nm. The proposed LC method is simple and selective for the determination of the stereoisomers of epalrestat in the drug substance with a limit of detection and quantification of 3.9 μg/mL and 4.9 μg/mL, respectively. The stereoisomers were identified by liquid chromatography-mass spectrometry (LC-MS).

  1. A novel amide stationary phase for hydrophilic interaction liquid chromatography and ion chromatography.

    Science.gov (United States)

    Shen, Guobin; Zhang, Feifang; Yang, Bingcheng; Chu, Changhu; Liang, Xinmiao

    2013-10-15

    A novel amide stationary phase (ASP) for hydrophilic interaction liquid chromatography (HILIC) has been prepared via the Click chemistry method. It was based on the strategy that the amino group of Asparagine was easily transferred to the corresponding azido group and then clicked onto terminal alkyne-silica gel in the presence of Cu(I)-based catalyst. For the tested polar compounds including nucleosides and nucleic acid bases, ASP-based column has demonstrated good performance in terms of separation efficiency and column stability, and the retention mechanism was found to match well the typical HILIC retention. In addition, the ASP described here showed much better selectivity in separation of inorganic anions under ion chromatography mode relative to other kinds of commercial ASP.

  2. Fundamentals of the Theory of Capillary Gas-Liquid-Solid Chromatography

    Science.gov (United States)

    Berezkin, Viktor G.; Zolotarev, P. P.

    1984-11-01

    It is shown that the known instances of the separation of volatile compounds actually refer to gas-liquid-solid chromatography and not gas-liquid chromatography, the walls of the capillary column fulfilling the function of the solid. The theories of the retention and spreading of the chromatographic bands in elution gas-liquid-solid chromatography are examined. The results of theoretical and experimental studies indicate the need to take into account the role of adsorption in capillary gas-liquid chromatography. The bibliography includes 140 references.

  3. Analysis of Some Biogenic Amines by Micellar Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Irena Malinowska

    2012-01-01

    Full Text Available Micellar liquid chromatography (MLC with the use of high performance liquid chromatography (HPLC was used to determine some physicochemical parameters of six biogenic amines: adrenaline, dopamine, octopamine, histamine, 2-phenylethylamine, and tyramine. In this paper, an influence of surfactant’s concentration and pH of the micellar mobile phase on the retention of the tested substances was examined. To determine the influence of surfactant’s concentration on the retention of the tested amines, buffered solutions (at pH 7.4 of ionic surfactant—sodium dodecyl sulfate SDS (at different concentrations with acetonitrile as an organic modifier (0.8/0.2 v/v were used as the micellar mobile phases. To determine the influence of pH of the micellar mobile phase on the retention, mobile phases contained buffered solutions (at different pH values of sodium dodecyl sulfate SDS (at 0.1 M with acetonitrile (0.8/0.2 v/v. The inverse of value of retention factor (1/ versus concentration of micelles ( relationships were examined. Other physicochemical parameters of solutes such as an association constant analyte—micelle (ma—and partition coefficient of analyte between stationary phase and water (hydrophobicity descriptor (swΦ were determined by the use of Foley’s equation.

  4. Dispersive liquid-liquid microextraction coupled to liquid chromatography for thiamine determination in foods.

    Science.gov (United States)

    Viñas, Pilar; López-García, Ignacio; Bravo-Bravo, María; Briceño, Marisol; Hernández-Córdoba, Manuel

    2012-05-01

    A miniaturized dispersive liquid-liquid microextraction (DLLME) procedure coupled to liquid chromatography (LC) with fluorimetric detection was evaluated for the preconcentration and determination of thiamine (vitamin B(1)). Derivatization was carried out by chemical oxidation of thiamine with 5 × 10(-5) M ferricyanide at pH 13 to form fluorescent thiochrome. For DLLME, 0.5 mL of acetonitrile (dispersing solvent) containing 90 μL of tetrachloroethane (extraction solvent) was rapidly injected into 10 mL of sample solution containing the derivatized thiochrome and 24% (w/v) sodium chloride, thereby forming a cloudy solution. Phase separation was carried out by centrifugation, and a volume of 20 μL of the sedimented phase was submitted to LC. The mobile phase was a mixture of a 90% (v/v) 10 mM KH(2)PO(4) (pH 7) solution and 10% (v/v) acetonitrile at 1 mL min(-1). An amide-based stationary phase involving a ligand with amide groups and the endcapping of trimethylsilyl was used. Specificity, linearity, precision, recovery, and sensitivity were satisfactory. Calibration graph was carried out by the standard additions method and was linear between 1 and 10 ng mL(-1). The detection limit was 0.09 ng mL(-1). The selectivity of the method was judged from the absence of interfering peaks at the thiamine elution time for blank chromatograms of unspiked samples. A relative standard deviation of 3.2% was obtained for a standard solution containing thiamine at 5 ng mL(-1). The esters thiamine monophosphate and thiamine pyrophosphate can also be determined by submitting the sample to successive acid and enzymatic treatments. The method was applied to the determination of thiamine in different foods such as beer, brewer's yeast, honey, and baby foods including infant formulas, fermented milk, cereals, and purees. For the analysis of solid samples, a previous extraction step was applied based on an acid hydrolysis with trichloroacetic acid. The reliability of the procedure was

  5. Purification of flavonoids from licorice using an off-line preparative two-dimensional normal-phase liquid chromatography/reversed-phase liquid chromatography method.

    Science.gov (United States)

    Fan, Yunpeng; Fu, Yanhui; Fu, Qing; Cai, Jianfeng; Xin, Huaxia; Dai, Mei; Jin, Yu

    2016-07-01

    An orthogonal (71.9%) off-line preparative two-dimensional normal-phase liquid chromatography/reversed-phase liquid chromatography method coupled with effective sample pretreatment was developed for separation and purification of flavonoids from licorice. Most of the nonflavonoids were firstly removed using a self-made Click TE-Cys (60 μm) solid-phase extraction. In the first dimension, an industrial grade preparative chromatography was employed to purify the crude flavonoids. Click TE-Cys (10 μm) was selected as the stationary phase that provided an excellent separation with high reproducibility. Ethyl acetate/ethanol was selected as the mobile phase owing to their excellent solubility for flavonoids. Flavonoids co-eluted in the first dimension were selected for further purification using reversed-phase liquid chromatography. Multiple compounds could be isolated from one normal-phase fraction and some compounds with bad resolution in one-dimensional liquid chromatography could be prepared in this two-dimensional system owing to the orthogonal separation. Moreover, this two-dimensional liquid chromatography method was beneficial for the preparation of relatively trace flavonoid compounds, which were enriched in the first dimension and further purified in the second dimension. Totally, 24 flavonoid compounds with high purity were obtained. The results demonstrated that the off-line two-dimensional liquid chromatography method was effective for the preparative separation and purification of flavonoids from licorice.

  6. Rapid determination of some psychotropic drugs in complex matrices by tandem dispersive liquid-liquid microextraction followed by high performance liquid chromatography.

    Science.gov (United States)

    Asghari, Alireza; Fahimi, Ebrahim; Bazregar, Mohammad; Rajabi, Maryam; Boutorabi, Leila

    2017-03-15

    Simple and rapid determinations of some psychotropic drugs in some pharmaceutical wastewater and human plasma samples were successfully accomplished via the tandem dispersive liquid-liquid microextraction combined with high performance liquid chromatography-ultraviolet detection (TDLLME-HPLC-UV). TDLLME of the three psychotropic drugs clozapine, chlorpromazine, and thioridazine was easily performed through two consecutive dispersive liquid-liquid microextractions. By performing this convenient method, proper sample preconcentrations and clean-ups were achieved in just about 7min. In order to achieve the best extraction efficiency, the effective parameters involved were optimized. The optimal experimental conditions consisted of 100μL of CCl4 (as the extraction organic solvent), and the pH values of 13 and 2 for the donor and acceptor phases, respectively. Under these optimum experimental conditions, the proposed TDLLME-HPLC-UV technique provided a good linearity in the range of 5-3000ngmL(-1) for the three psychotropic drugs with the correlation of determinations (R(2)s) higher than 0.996. The limits of quantification (LOQs) and limits of detection (LODs) obtained were 5.0ngmL(-1) and 1.0-1.5ngmL(-1), respectively. Also the proper enrichment factors (EFs) of 96, 99, and 88 for clozapine, chlorpromazine, and thioridazine, respectively, and good extraction repeatabilities (relative standard deviations below 9.3%, n=5) were obtained.

  7. Evaluation between ultrahigh pressure liquid chromatography and high-performance liquid chromatography analytical methods for characterizing natural dyestuffs.

    Science.gov (United States)

    Serrano, Ana; van Bommel, Maarten; Hallett, Jessica

    2013-11-29

    An evaluation was undertaken of ultrahigh pressure liquid chromatography (UHPLC) in comparison to high-performance liquid chromatography (HPLC) for characterizing natural dyes in cultural heritage objects. A new UHPLC method was optimized by testing several analytical parameters adapted from prior UHPLC studies developed in diverse fields of research. Different gradient elution programs were tested on seven UHPLC columns with different dimensions and stationary phase compositions by applying several mobile phases, flow rates, temperatures, and runtimes. The UHPLC method successfully provided more improved data than that achieved by the HPLC method. Indeed, even though carminic acid has shown circa 146% higher resolution with HPLC, UHPLC resulted in an increase of 41-61% resolution and a decrease of 91-422% limit of detection, depending on the dye compound. The optimized method was subsequently assigned to analyse 59 natural reference materials, in which 85 different components were ascribed with different physicochemical properties, in order to create a spectral database for future characterization of dyes in cultural heritage objects. The majority of these reference samples could be successfully distinguished with one single method through the examination of these compounds' retention times and their spectra acquired with a photodiode array detector. These results demonstrate that UHPLC analyses are extremely valuable for the acquisition of more precise chromatographic information concerning natural dyes with complex mixtures of different and/or closely related physicochemical properties, essential for distinguishing similar species of plants and animals used to colour cultural heritage objects.

  8. Comprehensive characterization of Stevia rebaudiana using two-dimensional reversed-phase liquid chromatography/hydrophilic interaction liquid chromatography.

    Science.gov (United States)

    Fu, Qing; Guo, Zhimou; Zhang, Xiuli; Liu, Yanfang; Liang, Xinmiao

    2012-07-01

    Two-dimensional reversed-phase liquid chromatography/hydrophilic interaction liquid chromatography (2D-RPLC/HILIC) system was successfully applied for comprehensive characterization of steviol glycosides from Stevia rebaudiana. The experiments were performed in offline mode using an XCharge C18 column in first dimension and an XAmide column in second dimension. In first dimension, preliminary separation of Stevia aqueous extract was accomplished and 30 fractions were collected. Then fractions 1-20 were selected for further purification and 13 compounds with high purity were obtained in second dimension. Comprehensive characterization of these compounds was completed by determination of their retention time, accurate molecular weight, diagnostic fragmentation ions, and nuclear magnetic resonance spectroscopy. As a result, all nine known steviol glycosides, as well as other four steviol glycosides were fully purified. The result demonstrated that this procedure is an effective approach for the preparative separation and comprehensive characterization of steviol glycosides in Stevia. This 2D-RPLC/HILIC method will be a promising tool for the purification of low-abundance compounds from natural products.

  9. Method transfer from high-pressure liquid chromatography to ultra-high-pressure liquid chromatography. II. Temperature and pressure effects.

    Science.gov (United States)

    Åsberg, Dennis; Samuelsson, Jörgen; Leśko, Marek; Cavazzini, Alberto; Kaczmarski, Krzysztof; Fornstedt, Torgny

    2015-07-03

    The importance of the generated temperature and pressure gradients in ultra-high-pressure liquid chromatography (UHPLC) are investigated and compared to high-pressure liquid chromatography (HPLC). The drug Omeprazole, together with three other model compounds (with different chemical characteristics, namely uncharged, positively and negatively charged) were used. Calculations of the complete temperature profile in the column at UHPLC conditions showed, in our experiments, a temperature difference between the inlet and outlet of 16 °C and a difference of 2 °C between the column center and the wall. Through van't Hoff plots, this information was used to single out the decrease in retention factor (k) solely due to the temperature gradient. The uncharged solute was least affected by temperature with a decrease in k of about 5% while for charged solutes the effect was more pronounced, with k decreases up to 14%. A pressure increase of 500 bar gave roughly 5% increase in k for the uncharged solute, while omeprazole and the other two charged solutes gave about 25, 20 and 15% increases in k, respectively. The stochastic model of chromatography was applied to estimate the dependence of the average number of adsorption/desorption events (n) and the average time spent by a molecule in the stationary phase (τs) on temperature and pressure on peak shape for the tailing, basic solute. Increasing the temperature yielded an increase in n and decrease in τs which resulted in less skew at high temperatures. With increasing pressure, the stochastic modeling gave interesting results for the basic solute showing that the skew of the peak increased with pressure. The conclusion is that pressure effects are more pronounced for both retention and peak shape than the temperature effects for the polar or charged compounds in our study.

  10. Analysis of quality of aviation lubricating oils by means of liquid and gas-liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Kholostova, G.G.; Bakunin, V.N.; Shimonaev, G.S.

    1987-01-01

    The authors examine the basic methodological aspects of chromatographic analysis of the quality of oils for aircraft gas turbine engines, and certain relationships in oil aging that have been established on this basis. A commercial ester (designated PEE) was selected for investigation of pentaerythritol and C/sub 5/-C/sub 9/ synthetic fatty acids (SFA) which serves as the synthetic base stock for a number of aviation oils. The changes in PEE composition upon oxidation, with or without additives, were evaluated by means of gas-liquid chromatography in a Tsvet-100 chromatograph with a flame ionization detector. The results from examination of the original and oxidized PEE samples by means of gas and liquid chromatography are presented.

  11. Purification of amide alkaloids from Piper longum L. using preparative two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography.

    Science.gov (United States)

    Li, Kuiyong; Zhu, Wenya; Fu, Qing; Ke, Yanxiong; Jin, Yu; Liang, Xinmiao

    2013-06-07

    A comprehensive off-line two-dimensional liquid chromatography (2D-LC) method coupling normal phase liquid chromatography (NPLC) and reversed phase liquid chromatography (RPLC) was developed for separation and purification of amide alkaloids from Piper longum L. In the first dimension, the crude alkaloid fractions were separated in NPLC mode and 20 fractions were collected. Then fractions 5-20 were selected for further purification in RPLC mode in the second dimension. The purities of RPLC fractions with similar structures were all identified accurately by ultra performance liquid chromatography (UPLC). In total, 28 compounds with high purity were obtained and their structures were comprehensively characterized by electrospray ionization-mass spectrometry (ESI-MS) and nuclear magnetic resonance (NMR) spectroscopy. The results demonstrate that this 2D NPLC × RPLC method with good orthogonality (58.3%) was effective for the preparative separation and purification of amide alkaloids from Piper longum L.

  12. Sheath liquid effects in capillary high-performance liquid chromatography-electrospray mass spectrometry of oligonucleotides.

    Science.gov (United States)

    Huber, C G; Krajete, A

    2000-02-18

    Fused-silica capillary columns of 200 microm inner diameter were packed with micropellicular, octadecylated, 2.3 microm poly(styrene-divinylbenzene) particles and applied to the separation of oligonucleotides by ion-pair reversed-phase high-performance liquid chromatography. Oligonucleotides were eluted at 50 degrees C with gradients of 3-13% acetonitrile in 50 mM triethylammonium bicarbonate. Addition of sheath liquid to the column effluent allowed the detection of oligonucleotides by electrospray ionization mass spectrometry using full-scan data acquisition with a detectability comparable to that obtained with UV detection. The signal-to-noise ratios with different sheath liquids increased in the order isopropanolliquid was found to influence the charge state distribution of oligonucleotides longer than 20 nucleotide units whereas no significant effect was observed with shorter oligonucleotides. Organic acids and bases in the sheath liquid generally deteriorated the signal-to-noise ratios in the chromatograms and mass spectra mainly because of increased background noise. Only a few charge states were observed in the mass spectra of oligonucleotides because of charge state reduction due to the presence of carbonic acid in the eluent. With triethylammonium hydrogencarbonate as chromatographic eluent and acetonitrile as sheath liquid, very few cation adducts of oligonucleotides were observed in the mass spectra. However, the presence of small amounts of monopotassium adducts enabled the calculation of the charge state of multiply charged ions. With acetonitrile as sheath liquid, 710 amol of a 16-mer oligonucleotide were detected using selected ion monitoring data acquisition with a signal-to-noise ratio of 3:1. Finally, capillary ion-pair reversed-phase high-performance liquid chromatography-electrospray ionization mass spectrometry was

  13. Identification of Unknown Microcontaminants in Dutch River Water by Liquid Chromatography-High Resolution Mass Spectrometry and Nuclear Magnetic Resonance Spectroscopy.

    NARCIS (Netherlands)

    Leerdam, van J.A.; Vervoort, J.J.M.; Stroomberg, G.; Voogt, de P.

    2014-01-01

    In the past decade during automated surface water monitoring in the river Meuse at border station Eijsden in The Netherlands, a set of unknown compounds were repeatedly detected by online liquid chromatography-diode-array detection in a relatively high signal intensity. Because of the unknown nature

  14. Identification of unknown microcontaminants in Dutch river water by liquid chromatography-high resolution mass spectrometry and nuclear magnetic Resonance spectroscopy

    NARCIS (Netherlands)

    van Leerdam, J.A.; Vervoort, J.; Stroomberg, G.; de Voogt, P.

    2014-01-01

    In the past decade during automated surface water monitoring in the river Meuse at border station Eijsden in The Netherlands, a set of unknown compounds were repeatedly detected by online liquid chromatography-diode-array detection in a relatively high signal intensity. Because of the unknown nature

  15. Determination of sulfonamides in butter samples by ionic liquid magnetic bar liquid-phase microextraction high-performance liquid chromatography.

    Science.gov (United States)

    Wu, Lijie; Song, Ying; Hu, Mingzhu; Xu, Xu; Zhang, Hanqi; Yu, Aimin; Ma, Qiang; Wang, Ziming

    2015-01-01

    A novel, simple, and environmentally friendly pretreatment method, ionic liquid magnetic bar liquid-phase microextraction, was developed for the determination of sulfonamides in butter samples by high-performance liquid chromatography. The ionic liquid magnetic bar was prepared by inserting a stainless steel wire into the hollow of a hollow fiber and immobilizing ionic liquid in the micropores of the hollow fiber. In the extraction process, the ionic liquid magnetic bars were used to stir the mixture of sample and extraction solvent and enrich the sulfonamides in the mixture. After extraction, the analyte-adsorbed ionic liquid magnetic bars were readily isolated with a magnet from the extraction system. It is notable that the present method was environmentally friendly since water and only several microliters of ionic liquid were used in the whole extraction process. Several parameters affecting the extraction efficiency were investigated and optimized, including the type of ionic liquid, sample-to-extraction solvent ratio, the number of ionic liquid magnetic bars, extraction temperature, extraction time, salt concentration, stirring speed, pH of the extraction solvent, and desorption conditions. The recoveries were in the range of 73.25-103.85 % and the relative standard deviations were lower than 6.84 %. The experiment results indicated that the present method was effective for the extraction of sulfonamides in high-fat content samples.

  16. Determination of bromate in drinking water by ultraperformance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Alsohaimi, Ibrahim Hotan; Alothman, Zeid Abdullah; Khan, Mohammad Rizwan; Abdalla, Mohammad Abulhassan; Busquets, Rosa; Alomary, Ahmad Khodran

    2012-10-01

    Bromate is a byproduct formed as a result of disinfection of bromide-containing source water with ozone or hypochlorite. The International Agency for Research on Cancer has recognized bromate as a possible human carcinogen, thus it is essential to determine in drinking water. Present work highlights a development of sensitive and fast analytical method for bromate determination in drinking water by using ultraperformance liquid chromatography-tandem mass spectrometry. The quality parameters of the developed method were established, obtaining very low limit of detection (0.01 ng/mL), repeatability and reproducibility have been found to be less than 3% in terms of relative standard deviation when analyzing a bromate standard at 0.05 μg/mL with 0.4 min analysis time. Developed method was applied for the analysis of metropolitan and bottled water from Saudi Arabia; 22 samples have been analyzed. Bromate was detected in the metropolitan water samples (from desalinization source) at concentrations ranging between 3.43 and 75.04 ng/mL and in the bottled water samples at concentrations ranging between 2.07 and 21.90 ng/mL. Moreover, in comparison to established analytical methods such as liquid chromatography-tandem mass spectrometry, the proposed method was found to be very sensitive, selective and rapid for the routine analysis of bromate at low level in drinking water.

  17. Determination of sedative hypnotics in sewage sludge by pressurized liquid extraction with high-performance liquid chromatography and tandem mass spectrometry.

    Science.gov (United States)

    Arbeláez, Paula; Granados, Judith; Borrull, Francesc; Marcé, Rosa Maria; Pocurull, Eva

    2014-12-01

    This paper describes a method for the determination of eight sedative hypnotics (benzodiazepines and barbiturates) in sewage sludge using pressurized liquid extraction and liquid chromatography with tandem mass spectrometry. Pressurized liquid extraction operating conditions were optimized and maximum recoveries were reached using methanol under the following operational conditions: 100ºC, 1500 psi, extraction time of 5 min, one extraction cycle, flush volume of 60% and purge time of 120 s. Pressurized liquid extraction recoveries were higher than 88% for all the compounds except for carbamazepine (55%). The repeatability and reproducibility between days, expressed as relative standard deviation (n = 5), were lower than 6 and 10%, respectively. The detection limits for all compounds were lower than 12.5 μg/kg of dry weight. The method was applied to determine benzodiazepines and barbiturates in sewage sludge from urban sewage treatment plants, and carbamazepine showed the highest concentration (7.9-18.9 μg/kg dry weight).

  18. Recent advances in ultra-high performance liquid chromatography for the analysis of traditional chinese medicine

    Science.gov (United States)

    Traditional Chinese medicines (TCMs) have been widely used for the prevention and treatment of various diseases for thousands of years in China. Ultra Performance Liquid Chromatography (UHPLC) is a relatively new technique offering new possibilities in liquid chromatography. This paper reviews recen...

  19. Determination of Roxarsone in feeds using solid phase extraction and liquid chromatography with ultraviolet detection.

    Science.gov (United States)

    Sapp, R E; Davidson, S

    1993-01-01

    A method is presented for detection and quantitation of Roxarsone in poultry feed by liquid chromatography. The drug is extracted by phosphate buffer and determined by solid phase extraction and reversed-phase liquid chromatography. Recoveries of the sample spikes and fortified field samples agree closely with those obtained by the standard spectrophotometric method.

  20. Applications of nanomaterials in liquid chromatography: opportunities for separation with high efficiency and selectivity.

    Science.gov (United States)

    Zhang, Zhengxiang; Wang, Zhiyong; Liao, Yiping; Liu, Huwei

    2006-08-01

    During recent decades, great efforts have been made to improve the chemical stability, selectivity, and separation efficiency of stationary phases in liquid chromatography. Significant progress has been achieved, especially after the introduction of nanomaterials into separation science. This review covers the applications of nanomaterials playing various roles in liquid chromatography. Future possibilities for developing nanomaterial-based stationary phases are also discussed.

  1. Investigating the Retention Mechanisms of Liquid Chromatography Using Solid-Phase Extraction Cartridges

    Science.gov (United States)

    O'Donnell, Mary E.; Musial, Beata A.; Bretz, Stacey Lowery; Danielson, Neil D.; Ca, Diep

    2009-01-01

    Liquid chromatography (LC) experiments for the undergraduate analytical laboratory course often illustrate the application of reversed-phase LC to solve a separation problem, but rarely compare LC retention mechanisms. In addition, a high-performance liquid chromatography instrument may be beyond what some small colleges can purchase. Solid-phase…

  2. Nano-liquid chromatography in pharmaceutical and biomedical research.

    Science.gov (United States)

    Gama, Mariana Roberto; Collins, Carol H; Bottoli, Carla B G

    2013-08-01

    Miniaturized separation techniques have emerged as environmentally friendly alternatives to available separation methods. Nano-liquid chromatography (nano-LC), microchip devices and nano-capillary electrophoresis are miniaturized methods that minimize reagent consumption and waste generation. Furthermore, the low levels of analytes, especially in biological samples, promote the search for more highly sensitive techniques; coupled to mass spectrometry, nano-LC has great potential to become an indispensable tool for routine analysis of biomolecules. This short review presents the fundamental aspects of nano-LC analytical instrumentation, discussing practical considerations and the primary differences between miniaturized and conventional instrumentation. Some theoretical aspects are discussed to better explain both the potential and the principal limitations of nano-LC. Recent pharmaceutical and biomedical applications of this separation technique are also presented to indicate the satisfactory performance for complex matrices, especially for proteomic analysis, that is obtained with nano-LC.

  3. Biological Fingerprinting of Herbal Samples by Means of Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Łukasz Cieśla

    2012-01-01

    Full Text Available Biological chromatographic fingerprinting is a relatively new concept in the quality control of herbal samples. Originally it has been developed with the application of HPLC, and recently herbal samples' biological profiles have been obtained by means of thin-layer chromatography (TLC. This paper summarizes the application of liquid chromatographic techniques for the purpose of biological fingerprint analysis (BFA of complex herbal samples. In case of biological TLC fingerprint, which is a relatively novel solution, perspectives of its further development are outlined in more detail. Apart from already published data, some novel results are also shown and briefly discussed. The paper aims at drawing scientists' attention to the unique solutions offered by biological fingerprint construction.

  4. Protein identification using nano liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Negroni, Luc

    2007-01-01

    Tandem mass spectrometry is an efficient technique for the identification of peptides on the basis of their fragmentation pattern (MS/MS scan). It can generate individual spectra for each peptide, thereby creating a powerful tool for protein identification on the basis of peptide characterization. This important advance in automatic data acquisition has allowed an efficient association between liquid chromatography and tandem mass spectrometry, and the use of nanocolumns and nanoelectrospray ionization has dramatically increased the efficiency of this method. Now large sets of peptides can be identified at a femtomole level. At the end of the process, batch processing of the MS/MS spectra produces peptide lists that identify purified proteins or protein mixtures with high confidence.

  5. Microfluidic liquid chromatography system for proteomic applications and biomarker screening.

    Science.gov (United States)

    Lazar, Iulia M; Trisiripisal, Phichet; Sarvaiya, Hetal A

    2006-08-01

    A microfluidic liquid chromatography (LC) system for proteomic investigations that integrates all the necessary components for stand-alone operation, i.e., pump, valve, separation column, and electrospray interface, is described in this paper. The overall size of the LC device is small enough to enable the integration of two fully functional separation systems on a 3 in. x 1 in. glass microchip. A multichannel architecture that uses electroosmotic pumping principles provides the necessary functionality for eluent propulsion and sample valving. The flow rates generated within these chips are fully consistent with the requirements of nano-LC platforms that are routinely used in proteomic applications. The microfluidic device was evaluated for the analysis of a protein digest obtained from the MCF7 breast cancer cell line. The cytosolic protein extract was processed according to a shotgun protocol, and after tryptic digestion and prefractionation using strong cation exchange chromatography (SCX), selected sample subfractions were analyzed with conventional and microfluidic LC platforms. Using similar experimental conditions, the performance of the microchip LC was comparable to that obtained with benchtop instrumentation, providing an overlap of 75% in proteins that were identified by more than two unique peptides. The microfluidic LC analysis of a protein-rich SCX fraction enabled the confident identification of 77 proteins by using conventional data filtering parameters, of 39 proteins with p screening applications.

  6. Gradient chromatofocusing high-performance liquid chromatography. I. Practical aspects.

    Science.gov (United States)

    Liu, Y; Anderson, D J

    1997-02-21

    In this work, a versatile method for generating linear pH gradients using weak anion-exchange HPLC has been developed, which is termed gradient chromatofocusing high-performance liquid chromatography. This method utilizes a linear external pH gradient generated in the mobile phase entering the column (inlet pH gradient), superimposed on an internally-generated pH gradient within the column (column pH gradient), which results from the buffering action of the ion exchanger on the mobile phase and vice versa. The method shows significant advantages over conventional chromatofocusing, including: decreased expense due to the use of common buffer components, ease of adjusting the slope of the pH gradient produced at the outlet of the column (outlet pH gradient) through the manipulation of the inlet pH gradient and the ability of using high concentration buffers in the mobile phase. Chromatography of fibrinogen degradation products was done using gradient chromatofocusing. Bandwidths comparable to conventional chromatofocusing were obtained in the separation of fibrinogen degradation products.

  7. Towards Chip Scale Liquid Chromatography and High Throughput Immunosensing

    Energy Technology Data Exchange (ETDEWEB)

    Ni, Jing [Iowa State Univ., Ames, IA (United States)

    2000-09-21

    This work describes several research projects aimed towards developing new instruments and novel methods for high throughput chemical and biological analysis. Approaches are taken in two directions. The first direction takes advantage of well-established semiconductor fabrication techniques and applies them to miniaturize instruments that are workhorses in analytical laboratories. Specifically, the first part of this work focused on the development of micropumps and microvalves for controlled fluid delivery. The mechanism of these micropumps and microvalves relies on the electrochemically-induced surface tension change at a mercury/electrolyte interface. A miniaturized flow injection analysis device was integrated and flow injection analyses were demonstrated. In the second part of this work, microfluidic chips were also designed, fabricated, and tested. Separations of two fluorescent dyes were demonstrated in microfabricated channels, based on an open-tubular liquid chromatography (OT LC) or an electrochemically-modulated liquid chromatography (EMLC) format. A reduction in instrument size can potentially increase analysis speed, and allow exceedingly small amounts of sample to be analyzed under diverse separation conditions. The second direction explores the surface enhanced Raman spectroscopy (SERS) as a signal transduction method for immunoassay analysis. It takes advantage of the improved detection sensitivity as a result of surface enhancement on colloidal gold, the narrow width of Raman band, and the stability of Raman scattering signals to distinguish several different species simultaneously without exploiting spatially-separated addresses on a biochip. By labeling gold nanoparticles with different Raman reporters in conjunction with different detection antibodies, a simultaneous detection of a dual-analyte immunoassay was demonstrated. Using this scheme for quantitative analysis was also studied and preliminary dose-response curves from an immunoassay of a

  8. Predicting drug penetration across the blood-brain barrier: comparison of micellar liquid chromatography and immobilized artificial membrane liquid chromatography.

    Science.gov (United States)

    De Vrieze, Mike; Lynen, Frédéric; Chen, Kai; Szucs, Roman; Sandra, Pat

    2013-07-01

    Several in vitro methods have been tested for their ability to predict drug penetration across the blood-brain barrier (BBB) into the central nervous system (CNS). In this article, the performance of a variety of micellar liquid chromatographic (MLC) methods and immobilized artificial membrane (IAM) liquid chromatographic approaches were compared for a set of 45 solutes. MLC measurements were performed on a C18 column with sodium dodecyl sulfate (SDS), polyoxyethylene (23) lauryl ether (Brij35), or sodium deoxycholate (SDC) as surfactant in the micellar mobile phase. IAM liquid chromatography measurements were performed with Dulbecco's phosphate-buffered saline (DPBS) and methanol as organic modifier in the mobile phase. The corresponding retention and computed descriptor data for each solute were used for construction of models to predict transport across the blood-brain barrier (log BB). All data were correlated with experimental log BB values and the relative performance of the models was studied. SDS-based models proved most suitable for prediction of log BB values, followed closely by a simplified IAM method, in which it could be observed that extrapolation of retention data to 0% modifier in the mobile phase was unnecessary.

  9. Salting-out assisted liquid-liquid extraction coupled to dispersive liquid-liquid microextraction for the determination of chlorophenols in wine by high-performance liquid chromatography.

    Science.gov (United States)

    Fan, Yingying; Hu, Shibin; Liu, Shuhui

    2014-12-01

    A novel procedure of sample preparation combined with high-performance liquid chromatography with diode array detection is introduced for the analysis of highly chlorinated phenols (trichlorophenols, tetrachlorophenols, and pentachlorophenol) in wine. The main features of the proposed method are (i) low-toxicity diethyl carbonate as extraction solvent to selectively extract the analytes without matrix effect, (ii) the combination of salting-out assisted liquid-liquid extraction and dispersive liquid-liquid microextraction to achieve an enrichment factor of 334-361, and (iii) the extract is analyzed by high-performance liquid chromatography to avoid derivatization. Under the optimum conditions, correlation coefficients (r) were >0.997 for calibration curves in the range 1-80 ng/mL, detection limits and quantification limits ranged from 0.19 to 0.67 and 0.63 to 2.23 ng/mL, respectively, and relative standard deviation was wines, with recovery rates in the range 82-104%. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Simultaneous determination of steviol and steviol glycosides by liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Shah, Romina; De Jager, Lowri S; Begley, Timothy H

    2012-01-01

    A direct, versatile method for the determination of steviol and nine steviol glycosides in food products has been developed by using electrospray ionisation liquid chromatography-mass spectrometry in the negative-ion mode. Ten stevia compounds were readily separated on an amino column by using a gradient separation. Data for analyte quantification were collected in the selected ion monitoring mode, giving the method limit of detection of 0.01-0.34 µg g⁻¹ and repeatability at the limit of quantitation of 2%-15% relative standard deviation. Thirty-four commercially available food products were tested by using the optimised method, and in these products rebaudioside A and stevioside comprised 52%-100% of the total steviol glycosides. Multiple reaction monitoring data were collected to provide analyte confirmation. Stability data for rebaudioside A stored at room temperature, 40°C and 60°C over a period of 1-14 days are shown.

  11. Discrimination of eight chloramphenicol isomers by liquid chromatography tandem mass spectrometry in order to investigate the natural occurence of chloramphenicol

    NARCIS (Netherlands)

    Berendsen, B.J.A.; Zuidema, T.; Jong, de J.; Stolker, A.A.M.; Nielen, M.W.F.

    2011-01-01

    This paper describes the discrimination of eight different isomers of chloramphenicol (CAP), an antibiotic banned for use in food producing animals, by reversed phase and chiral liquid chromatography in combination with tandem mass spectrometric detection. Previously, by liquid chromatography couple

  12. Three dimensional liquid chromatography coupling ion exchange chromatography/hydrophobic interaction chromatography/reverse phase chromatography for effective protein separation in top-down proteomics.

    Science.gov (United States)

    Valeja, Santosh G; Xiu, Lichen; Gregorich, Zachery R; Guner, Huseyin; Jin, Song; Ge, Ying

    2015-01-01

    To address the complexity of the proteome in mass spectrometry (MS)-based top-down proteomics, multidimensional liquid chromatography (MDLC) strategies that can effectively separate proteins with high resolution and automation are highly desirable. Although various MDLC methods that can effectively separate peptides from protein digests exist, very few MDLC strategies, primarily consisting of 2DLC, are available for intact protein separation, which is insufficient to address the complexity of the proteome. We recently demonstrated that hydrophobic interaction chromatography (HIC) utilizing a MS-compatible salt can provide high resolution separation of intact proteins for top-down proteomics. Herein, we have developed a novel 3DLC strategy by coupling HIC with ion exchange chromatography (IEC) and reverse phase chromatography (RPC) for intact protein separation. We demonstrated that a 3D (IEC-HIC-RPC) approach greatly outperformed the conventional 2D IEC-RPC approach. For the same IEC fraction (out of 35 fractions) from a crude HEK 293 cell lysate, a total of 640 proteins were identified in the 3D approach (corresponding to 201 nonredundant proteins) as compared to 47 in the 2D approach, whereas simply prolonging the gradients in RPC in the 2D approach only led to minimal improvement in protein separation and identifications. Therefore, this novel 3DLC method has great potential for effective separation of intact proteins to achieve deep proteome coverage in top-down proteomics.

  13. A Method for the Quantitation of Trace Levels of Dimethyl Sulfoxide in Urine by High Performance Liquid Chromatography

    Science.gov (United States)

    1989-05-01

    HIGH PERFORMANCE LIQUID CHROMATOGRAPHY by...for the sample cleanup and concentration, followed by separation by reversed phase high performance liquid chromatography . EXPERIMENTAL Materials...DIMETHYL SULFOXIDE IN URINE BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY 4. AUTHORS (Last name, first name, middle initial. If military, show rank, e.g.

  14. Determination of Dimethyl Sulfoxide (DMSO), Ethanol (ETOH), Formamide (F) and Glycerol/Formal (GF) by High Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    1989-01-30

    HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC...Classification) (U) Determination of Dimethyl Sulfoxide (DMSO), Ethanol, (ETOH), Formamide (F), and Glycerol/ Formal (GF) by High Performance Liquid Chromatography (HPLC...and 5). High performance liquid chromatography (HPLC) was the analytical method of choice for analyzing DMSO, ethanol, formamide and

  15. Determination of 5-Bromo-2’-Deoxyuridine (BrdU) in Well Water by High Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    1992-09-01

    HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC...Securrty Classification) Determination of 5-Bromo-2’-Deoxyuridine (BrdU) in Well Water by High Performance Liquid Chromatography (hPLC) 12. PERSONAL...PLOT OF BrdU STABILITY VERSUS TIME ....................... 10 ii DETERMINATION OF 5-BROMO-2’-DEOXY-URIDINE (BrdU) IN WELL WATER BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

  16. Determination of Organic Pollutants in Small Samples of Groundwaters by Liquid-Liquid Extraction and Capillary Gas Chromatography

    DEFF Research Database (Denmark)

    Harrison, I.; Leader, R.U.; Higgo, J.J.W.;

    1994-01-01

    A method is presented for the determination of 22 organic compounds in polluted groundwaters. The method includes liquid-liquid extraction of the base/neutral organics from small, alkaline groundwater samples, followed by derivatisation and liquid-liquid extraction of phenolic compounds after...... neutralisation. The extracts were analysed by capillary gas chromatography. Dual detection by flame Ionisation and electron capture was used to reduce analysis time....

  17. Application of Genetic Algorithms for Parameter Estimation in Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Orestes Llanes Santiago

    2011-11-01

    Full Text Available Normal 0 21 false false false ES X-NONE X-NONE /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Tabla normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} In chromatography, complex inverse problems related to the parameters estimation and process optimization are presented. Metaheuristics methods are known as general purpose approximated algorithms which seek and hopefully find good solutions at a reasonable computational cost. These methods are iterative process to perform a robust search of a solution space. Genetic algorithms are optimization techniques based on the principles of genetics and natural selection. They have demonstrated very good performance as global optimizers in many types of applications, including inverse problems. In this work, the effectiveness of genetic algorithms is investigated to estimate parameters in liquid chromatography.

  18. Extensive database of liquid phase diffusion coefficients of some frequently used test molecules in reversed-phase liquid chromatography and hydrophilic interaction liquid chromatography.

    Science.gov (United States)

    Song, Huiying; Vanderheyden, Yoachim; Adams, Erwin; Desmet, Gert; Cabooter, Deirdre

    2016-07-15

    Diffusion plays an important role in all aspects of band broadening in chromatography. An accurate knowledge of molecular diffusion coefficients in different mobile phases is therefore crucial in fundamental column performance studies. Correlations available in literature, such as the Wilke-Chang equation, can provide good approximations of molecular diffusion under reversed-phase conditions. However, these correlations have been demonstrated to be less accurate for mobile phases containing a large percentage of acetonitrile, as is the case in hydrophilic interaction liquid chromatography. A database of experimentally measured molecular diffusion coefficients of some 45 polar and apolar compounds that are frequently used as test molecules under hydrophilic interaction liquid chromatography and reversed-phase conditions is therefore presented. Special attention is given to diffusion coefficients of polar compounds obtained in large percentages of acetonitrile (>90%). The effect of the buffer concentration (5-10mM ammonium acetate) on the obtained diffusion coefficients is investigated and is demonstrated to mainly influence the molecular diffusion of charged molecules. Diffusion coefficients are measured using the Taylor-Aris method and hence deduced from the peak broadening of a solute when flowing through a long open tube. The validity of the set-up employed for the measurement of the diffusion coefficients is demonstrated by ruling out the occurrence of longitudinal diffusion, secondary flow interactions and extra-column effects, while it is also shown that radial equilibration in the 15m long capillary is effective.

  19. Sensitive determination of melamine in milk and powdered infant formula samples by high-performance liquid chromatography using dabsyl chloride derivatization followed by dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Faraji, M; Adeli, M

    2017-04-15

    A new and sensitive pre-column derivatization with dabsyl chloride followed by dispersive liquid-liquid microextraction was developed for the analysis of melamine (MEL) in raw milk and powdered infant formula samples by high performance liquid chromatography (HPLC) with visible detection. Derivatization with dabsyl chloride leads to improving sensitivity and hydrophobicity of MEL. Under optimum conditions of derivatization and microextraction steps, the method yielded a linear calibration curve ranging from 1.0 to 500μgL(-1) with a determination coefficient (R(2)) of 0.9995. Limit of detection and limit of quantification were 0.1 and 0.3μgL(-1), respectively. The relative standard deviation (RSD%) for intra-day (repeatability) and inter-day (reproducibility) at 25 and 100μgL(-1) levels of MEL was less than 7.0% (n=6). Finally, the proposed method was successfully applied for the preconcentration and determination of MEL in different raw milk and powdered infant formula, and satisfactory results were obtained (relative recovery ⩾94%).

  20. Vortex-assisted low density solvent based demulsified dispersive liquid-liquid microextraction and high-performance liquid chromatography for the determination of organophosphorus pesticides in water samples.

    Science.gov (United States)

    Seebunrueng, Ketsarin; Santaladchaiyakit, Yanawath; Srijaranai, Supalax

    2014-05-01

    A simple, rapid, effective and eco-friendly preconcentration method, vortex-assisted low density solvent based solvent demulsified dispersive liquid-liquid microextraction (VLDS-SD-DLLME), followed by high performance liquid chromatography-diode array detector (HPLC-DAD) analysis, has been developed for the first time for the determination of four organophosphorus pesticides (OPPs) (e.g., azinphos-methyl, parathion-methyl, fenitrothion and diazinon) in environmental water samples. In this preconcentration procedure, an emulsion was obtained after the mixture of extraction solvent (1-dodecanol) and dispersive solvent (acetonitrile, ACN) was injected rapidly into 10 mL of the sample solution. The vortex agitator aided the dispersion of the extraction solvent into the sample solution. After the formation of an emulsion, the demulsifier (ACN) was added, resulting in the rapid separation of the mixture into two phases without centrifugation. Under optimal conditions, the proposed method provided high extraction efficiency (90-99%), good linearity range (0.5-500 ng mL(-1)), low limits of detection (0.25-1 ng mL(-1)) and good repeatability and recoveries were obtained.

  1. Dispersive liquid-liquid microextraction followed by high-performance liquid chromatography-diode array detection as an efficient and sensitive technique for determination of antioxidants.

    Science.gov (United States)

    Farajzadeh, Mir Ali; Bahram, Morteza; Jönsson, Jan Ake

    2007-05-15

    Dispersive liquid-liquid microextraction (DLLME) and high performance liquid chromatography-diode array detection (HPLC-DAD) was presented for extraction and determination of Irganox 1010, Irganox 1076 and Irgafos 168 (antioxidants) in aqueous samples. Carbon tetrachloride at microliter volume level and acetonitrile were used as extraction and dispersive solvents, respectively. The main advantages of method are high speed, high enrichment factor, high recovery, good repeatability and extraction solvent volume at microL level. Limit of detection for analytes is between 3 and 7 ng mL(-1). One variable at a time optimization and response surface modeling were used to obtain optimum conditions for microextraction procedure and nearly same experimental conditions were obtained using both optimization methods. Recoveries in the ranges 78-86% and 84-110% were obtained by one variable at a time and response surface modeling, respectively. Using tap water and packed water as matrices do not show any detrimental effect on the extraction recoveries and enrichment factors of analytes.

  2. Determination of estrogenic mycotoxins in environmental water samples by low-toxicity dispersive liquid-liquid microextraction and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Emídio, Elissandro Soares; da Silva, Claudia Pereira; de Marchi, Mary Rosa Rodrigues

    2015-04-24

    A novel, simple, rapid and eco-friendly method based on dispersive liquid-liquid microextraction using a bromosolvent was developed to determine six estrogenic mycotoxins (zearalenone, zearalanone, α-zearalanol, β-zearalanol, α-zearalenol and β-zearalenol) in water samples by liquid chromatography-electrospray ionization tandem mass spectrometry in the negative mode (LC-ESI-MS/MS). The optimal conditions for this method include the use of 100 μL bromocyclohexane as an extraction solvent (using a non-dispersion solvent), 10 mL of aqueous sample (adjusted to pH 4), a vortex extraction time of 2 min, centrifugation for 10 min at 3500 rpm and no ionic strength adjustment. The calibration function was linear and was verified by applying the Mandel fitting test with a 95% confidence level. No matrix effect was observed. According to the relative standard deviations (RSDs), the precision was better than 13% for the repeatability and intermediate precision. The average recoveries of the spiked compounds ranged from 81 to 118%. The method limits of detection (LOD) and quantification (LOQ) considering a 125-fold pre-concentration step were 4-20 and 8-40 ng L(-1), respectively. Next, the method was applied to the analysis of the environmental aqueous samples, demonstrating the presence of β-zearalanol and zearalanone in the river water samples.

  3. Investigation of Symphytum cordatum alkaloids by liquid-liquid partitioning, thin-layer chromatography and liquid chromatography-ion-trap mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Mroczek, Tomasz [Department of Pharmacognosy with Medicinal Plants Laboratory, Medical University, 1 Chodzki St., 20-093 Lublin (Poland)]. E-mail: tmroczek@pharmacognosy.org; Ndjoko-Ioset, Karine [Laboratoire de Pharmacognosie et Phytochimie, Ecole de Pharmacie Geneve-Lausanne, Universite de Geneve, Quai Ernest-Ansermet 30, CH-1211 Geneva 4 (Switzerland); Glowniak, Kazimierz [Department of Pharmacognosy with Medicinal Plants Laboratory, Medical University, 1 Chodzki St., 20-093 Lublin (Poland); Mietkiewicz-Capala, Agnieszka [Department of Pharmacognosy with Medicinal Plants Laboratory, Medical University, 1 Chodzki St., 20-093 Lublin (Poland); Hostettmann, Kurt [Laboratoire de Pharmacognosie et Phytochimie, Ecole de Pharmacie Geneve-Lausanne, Universite de Geneve, Quai Ernest-Ansermet 30, CH-1211 Geneva 4 (Switzerland)

    2006-05-04

    From the alkalised crude extract of Symphytum cordatum (L.) W.K. roots, pyrrolizidine alkaloids (PAs) were extracted as free tertiary bases and polar N-oxides in a merely one-step liquid-liquid partitioning (LLP) in separation funnel and subsequently pre-fractionated by preparative multiple-development (MD) thin-layer chromatography (TLC) on silica gel plates. In this way three alkaloid fractions of different polarities and retention on silica gel plates were obtained as: the most polar N-oxides of the highest retention, the tertiary bases of medium retention, and diesterified N-oxides of the lowest retention. The former fraction was reduced into free bases by sodium hydrosulfite and purified by LLP on Extrelut-NT3 cartridge. It was further analysed together with the two other fractions by high-performance liquid chromatography (HPLC)-ion-trap mass spectrometry with atmospheric pressure chemical ionization (APCI) interface on XTerra C{sub 18} column using a gradient elution. Based on MS {sup n} spectra, 18 various alkaloids have been tentatively determined for the first time in this plant as the following types of structure: echimidine-N-oxide (three diasteroisomers), 7-sarracinyl-9-viridiflorylretronecine (two diasteroisomers), echimidine (two diasteroisomers), lycopsamine (two diasteroisomers), dihydroechinatine-N-oxide, dihydroheliospathuline-N-oxide, lycopsamine-N-oxide (three diasteroisomers), 7-acetyllycopsamine-N-oxide, symphytine-N-oxide (two diasteroisomers) and 2'',3''-epoxyechiumine-N-oxide.

  4. Quantitative determination of five ergot alkaloids in rye flour by liquid chromatography-electrospray ionisation tandem mass spectrometry.

    Science.gov (United States)

    Mohamed, Rayane; Gremaud, Eric; Richoz-Payot, Janique; Tabet, Jean-Claude; Guy, Philippe A

    2006-05-05

    A confirmatory method for detecting five ergot alkaloids, ergocristine, ergotamine, ergonovine, ergocornine and alpha-ergokryptine, in rye flour is described using high performance liquid chromatography coupled to tandem mass spectrometry detection by monitoring two transition reactions per analyte. The procedure entails a liquid-liquid extraction followed by a clean-up step using a C18 solid-phase extraction (SPE) cartridge. An analogue compound, methysergide hydrogen maleinate, was used to assess both repeatability sample preparation and potential MS response fluctuations. The method was fully validated according to the European Union (EU) criteria. Detection and quantification limits of all analytes were calculated ranging from 7 to 11 microg/kg and from 23 to 37 microg/kg, respectively. Fifteen rye flour samples were investigated with the newly developed method, and none of them were above the current Swiss limits of 200mg/kg for total ergot alkaloids.

  5. Preliminary validation of high performance liquid chromatography method for detection of methyl-testosterone residue in carp muscle

    Science.gov (United States)

    Jiang, Jie; Lin, Hong; Fu, Xiaoting; Li, Mingming

    2005-07-01

    The use of synthetic anabolic steroid methyltestosterone (MT) as growth promoter is prohibited in China. Validations of analytical methods for MT residue in food and the results obtained have become indispensable. The high performance liquid chromatography (HPLC) method for the detection of MT with liquid-liquid extraction by trichloromethane-methanol in carp muscle tissue was preliminarily validated with reference to the following parameters: recovery (accuracy) at the 1, 5 and l0 mgkg-1 level, between-run and within-run CV values (repeatability, also called relative standard deviation (RSD)) and limit of detection. The recoveries were above 80% and the between-run and within-run CV values below 10% for muscle tissue. The limit of detection was 0.05 mgkg-1.

  6. HIGH PERFORMANCE LIQUID CHROMATOGRAPHY DETECTORS – A REVIEW

    Directory of Open Access Journals (Sweden)

    Kaushal Ramni

    2011-05-01

    Full Text Available HPLC is the most versatile and widely used elution chromatography. The technique is used to resolve and determine species in a variety of organic, inorganic, biological, ionic and polymeric materials. Detector is the heart of an instrument and efficiency of system is dependent upon detecting techniques. Many types of HPLC detectors exist, each of which has some valuable performance feature such as refractive index detector, ultraviolet detector, fluorescent detector, electrochemical detector, electric conductivity detector, liquid light scattering detector, evaporative light scattering detector. Due to strong requirement for improvements in sensitivity, selectivity and other performance characteristics of the detector recent developments in conventional techniques and some other new technologies have been adopted such as laser light scattering detector, charged aerosol detector, nano quantity aerosol detector, chiral detector and pulsed amperometric detector. These detectors provide accurate concentration analysis, excellent sensitivity, wide dynamic range, consistent response and broad applicability of the drug components. Working of these detectors involve different principles such as optical techniques, aerosol based techniques, refractive methods, light scattering principle, amperometric and fluorescence. The present review enlightens both conventional and advanced techniques and compares their capabilities of analyzing drug components and need for new techniques for better and wide range of applicability.

  7. Determination of saffron quality by high-performance liquid chromatography.

    Science.gov (United States)

    Valle García-Rodríguez, M; Serrano-Díaz, Jéssica; Tarantilis, Petros A; López-Córcoles, Horacio; Carmona, Manuel; Alonso, Gonzalo L

    2014-08-13

    The aim of this work was to propose a high-performance liquid chromatography with diode array detection (HPLC-DAD) method for determining the three main compounds responsible for determining the quality of saffron (crocetin esters, picrocrocin, and safranal) by preparing an aqueous extract according to the ISO 3632 standard to solve the difficulty that this standard has for aroma and taste determination by ultraviolet-visible spectroscopy. Toward this aim, laboratory-isolated picrocrocin, a safranal standard with a purity of ≥ 88%, trans-crocetin di(β-D-gentiobiosyl) ester (trans-4-GG) and trans-crocetin (β-D-glucosyl)-(β-D-gentiobiosyl) ester (trans-3-Gg) standards, both with a purity of ≥ 99%, and 50 different saffron spice samples from Italy, Iran, Greece, and Spain were used in the intralaboratory validation of the HPLC method. The analytical method proposed was adequate in terms of linearity, selectivity, sensitivity, and accuracy for determining the three foremost parameters that define the quality of saffron using only a saffron solution prepared according to the ISO 3632 standard.

  8. Molecular simulation studies of reversed-phase liquid chromatography.

    Science.gov (United States)

    Lindsey, Rebecca K; Rafferty, Jake L; Eggimann, Becky L; Siepmann, J Ilja; Schure, Mark R

    2013-04-26

    Over the past 20 years, molecular simulation methods have been applied to the modeling of reversed-phase liquid chromatography (RPLC). The purpose of these simulations was to provide a molecular-level understanding of: (i) the structure and dynamics of the bonded phase and its interface with the mobile phase, (ii) the interactions of analytes with the bonded phase, and (iii) the retention mechanism for different analytes. However, the investigation of chromatographic systems poses significant challenges for simulations with respect to the accuracy of the molecular mechanics force fields and the efficiency of the sampling algorithms. This review discusses a number of aspects concerning molecular simulation studies of RPLC systems including the historical development of the subject, the background needed to understand the two prevalent techniques, molecular dynamics (MD) and Monte Carlo (MC) methods, and the wealth of insight provided by these simulations. Examples from the literature employing MD approaches and from the authors' laboratory using MC methods are discussed. The former can provide information on chain dynamics and transport properties, whereas the latter techniques are uniquely suited for the investigation of phase and sorption equilibria that underly RPLC retention, and both can be used to elucidate the bonded-chain conformations and solvent distributions. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Analysis of Cordyceps by multi-column liquid chromatography

    Directory of Open Access Journals (Sweden)

    Zhengming Qian

    2017-03-01

    Full Text Available Cordyceps is a famous traditional Chinese medicine (TCM that has been used in China for hundreds of years. In the present study a multi-column liquid chromatography (MC-LC system was developed for the qualitative analysis of macromolecules and micromolecules in Cordyceps. The MC-LC system includes a size exclusion pre-column, a size exclusion column (SEC and a reversed phase column (RP which were controlled by column-switching valves. The sample was separated by the size exclusion pre-column into two fractions (macromolecules and micromolecules. These fractions were further separated on SEC and RP columns, respectively. A diode array detector (DAD and a mass spectrometer (MS were used to detect the components. This MC-LC method was utilized for analysis of Cordyceps samples. Two macromolecular peaks and 15 micromolecular peaks were found in Cordyceps, and 11 of the micromolecular peaks were identified as adenosine-5′-monophosphate (AMP, phenylalanine, uridine, hypoxanthine, inosine, guanine, guanosine, deoxyadenosine-5′-monophosphate (dAMP, adenosine, adenine and cordycepin (or its isomer. This method is useful for quality control of Cordyceps.

  10. Analysis of Cordyceps by multi-column liquid chromatography.

    Science.gov (United States)

    Qian, Zhengming; Li, Shaoping

    2017-03-01

    Cordyceps is a famous traditional Chinese medicine (TCM) that has been used in China for hundreds of years. In the present study a multi-column liquid chromatography (MC-LC) system was developed for the qualitative analysis of macromolecules and micromolecules in Cordyceps. The MC-LC system includes a size exclusion pre-column, a size exclusion column (SEC) and a reversed phase column (RP) which were controlled by column-switching valves. The sample was separated by the size exclusion pre-column into two fractions (macromolecules and micromolecules). These fractions were further separated on SEC and RP columns, respectively. A diode array detector (DAD) and a mass spectrometer (MS) were used to detect the components. This MC-LC method was utilized for analysis of Cordyceps samples. Two macromolecular peaks and 15 micromolecular peaks were found in Cordyceps, and 11 of the micromolecular peaks were identified as adenosine-5'-monophosphate (AMP), phenylalanine, uridine, hypoxanthine, inosine, guanine, guanosine, deoxyadenosine-5'-monophosphate (dAMP), adenosine, adenine and cordycepin (or its isomer). This method is useful for quality control of Cordyceps.

  11. Electrochemical flow cell, particularly use with liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Matson, W.R.

    1983-11-08

    An amperometric cell modified for high pressure operation is described. The cell is a flow-through type cell defining a flow path and has at least one active testing electrode, at least one reference electrode and at least one counter electrode operatively disposed and electrically insulated from one another within the cell flow path. In a preferred embodiment the flow cell is encapsulated within a high impact, chemically resistant, chemically insulating material, and has a pair of high pressure resistance fittings communicating with the flow path and extending in part beyond the encapsulation. The cell has particular utility for use with a liquid chromatography separation and when placed in line upstream of sample injection, will remove selected electroactive components in the carrier fluid and thereby reduce background level of contaminents reaching the column and eluting from the column. The cell may also be placed in line following sample injection whereby it may be employed to electrochemically modify selected materials in the mobile phase whereby to change their chromatographic characteristics.

  12. Determination of Glimepiride in Human Plasma by Liquid Chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ho Hyun; Lee, Hee Joo [Seoul Clinical Laboratories, Seoul (Korea, Republic of); Chang, Kyu Young [Korean Biochip Society, Seoul (Korea, Republic of); Han, Sang Beom [ChungAng University, Seoul (Korea, Republic of)

    2004-01-15

    A sensitive method for quantitation of glimepiride in human plasma has been established using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS). Glipizide was used as an internal standard. Glimepiride and internal standard in plasma sample was extracted using diethyl etherethyl acetate (1 : 1). A centrifuged upper layer was then evaporated and reconstituted with the mobile phase of acetonitrile-5 mM ammonium acetate (60:40, pH 3.0). The reconstituted samples were injected into a C{sub 18} reversed-phase column. Using MS/MS in the multiple reaction monitoring (MRM) mode, glimepiride and glipizide were detected without severe interference from human plasma matrix. Glimepiride produced a protonated precursor ion ([M+H]{sup +}) at m/z 491 and a corresponding product ion at m/z 352. And the internal standard produced a protonated precursor ion ([M+H]{sup +}) at m/z 446 and a corresponding product ion at m/z 321. Detection of glimepiride in human plasma by the LC-ESI/MS/MS method was accurate and precise with a quantitation limit of 0.1 ng/mL. The validation, reproducibility, stability, and recovery of the method were evaluated. The method has been successfully applied to pharmacokinetic studies of glimepiride in human plasma

  13. Gradient chromatofocusing high-performance liquid chromatography. II. Theoretical aspects.

    Science.gov (United States)

    Liu, Y; Anderson, D J

    1997-02-21

    This article is Part II of a series describing a newly-developed gradient chromatofocusing high-performance liquid chromatography (HPLC) technique. Theoretical aspects of the technique are discussed. In gradient chromatofocusing, the column pH gradient with respect to column distance can be varied without necessarily affecting the outlet pH gradient with respect to time. Factors influencing the value of the slope of the column pH gradient are identified through derived equations and a computer simulation model. A newly-identified parameter is introduced, column travel time, which can be uniquely varied in gradient chromatofocusing. Experiments show increased conversion of fibrinogen to denatured forms with increased column travel time. Another unique aspect of gradient chromatofocusing is that the mobile phase buffer concentration can be manipulated without necessarily affecting the outlet pH gradient slope, giving the technique expanded versatility for optimizing the separation. In the present work, the pIapparent for fibrinogen is found to increase with increased mobile phase buffer concentration.

  14. Chromatographic analysis of olopatadine in hydrophilic interaction liquid chromatography.

    Science.gov (United States)

    Maksić, Jelena; Jovanović, Marko; Rakić, Tijana; Popović, Igor; Ivanović, Darko; Jančić-Stojanović, Biljana

    2015-01-01

    In this paper, chromatographic analysis of active substance olopatadine hydrochloride, which is used in eye drops as antihistaminic agent, and its impurity E isomer by hydrophilic interaction liquid chromatography (HILIC) and application of design of experiments (DoE) methodology are presented. In addition, benzalkonium chloride is very often used as a preservative in eye drops. Therefore, the evaluation of its chromatographic behavior in HILIC was carried out as well. In order to estimate chromatographic behavior and set optimal chromatographic conditions, DoE methodology was applied. After the selection of important chromatographic factors, Box-Behnken design was utilized, and on the basis of the obtained models factor effects were examined. Then, multi-objective robust optimization is performed aiming to obtain chromatographic conditions that comply with several quality criteria simultaneously: adequate and robust separation of critical peak pair and maximum retention of the first eluting peak. The optimal conditions are identified by using grid point search methodology. The experimental verification confirmed the adequacy of the defined optimal conditions. Finally, under optimal chromatographic conditions, the method was validated and applicability of the proposed method was confirmed.

  15. Separation of microcystins and nodularins by ultra performance liquid chromatography.

    Science.gov (United States)

    Spoof, Lisa; Neffling, Milla-Riina; Meriluoto, Jussi

    2009-11-15

    Four ultra performance liquid chromatography (UPLC) columns with different reversed-phase characteristics were tested in the chromatographic separation of 10 microcystins and three nodularins, cyanobacterial peptide toxins. The columns had been designed by the manufacturer to withstand the ultra-high pressure generated by sub-2microm stationary phase particles and the Waters ACQUITY UPLC system in ultra-fast separations. The gradient mobile phase consisted of water and acetonitrile, both acidified with trifluoroacetic acid, with three gradient rise times: 1, 1.5 and 2min. The UV detection of the toxins was performed by a photodiode array detector. The chromatographic performance was evaluated both visually and by calculating chromatographic parameters such as capacity factor, resolution, peak width at half height, selectivity and peak asymmetry. The best chromatographic performance as judged by visual inspection was given by the ACQUITY BEH Shield RP18 and ACQUITY BEH Phenyl columns. The BEH Shield RP18 column showed excellent selectivity and resolution of chosen peak pairs considered as critical. A further advantage of the UPLC system was the high sample throughput with a total analysis time of 3.12min (injection-to-injection) equalling to 461 separations per 24h.

  16. Simultaneous determination of cyclodol and diprazin by thin layer chromatography and high performance liquid chromatography.

    Science.gov (United States)

    Makharadze, R; Adeishvili, L; Chelidze, T; Imnadze, N; Nizharadze, N

    2009-11-01

    Ciklodol (trihexyphenidil)--the central and peripheral m-cholinoblocker is currently used with other antipsychotic drugs such as phenotiazines and tricycle antidepressants. For the purpose of simultaneous determination of ciklodol and diprazine, were selected two methods of analysis: Thin Layer Chromatography (TLC) and High Performance Liquid Chromatography (HPLC). During development of TLC method was studied the 10 visualizing system and 24 mobile systems. For individual or simultaneous determination of ciklodol and diprazine were recommended the following solvents' systems: 1. Toluene-acetone-ethanole-25%NH(4)OH (45:45: 7.5:2.5), 2. Hexane-ethyl acetate (15:5), 3. Chloroform-heptene-25%NH(4)OH (16:3:3), 4. Ethylacetate-hexane (10:10), 5. Acetonitrile-metanol (10:10) and 6.Heptene-chloroform-ethanol-25% NH(4)OH (5:10:3:1). As visualizing systems were chosen: Iodine vapors, blacklight (UV254) and reagent of FNP. Reagent of FNP gives colored spot just with diprazine and it is also could be used for separation of both objects in simultaneous analysis. Developed HPLC method of simultaneous determination of ciklodol and diprazine: like mobile phase is recommended: Acetonitril- 0.05M KH(2)PO4 (55:45) (v/v) +H(3)PO(4) (pH3.5), column EC250 x 4.6mm, with solid phase Nucleosil, flow rate 1ml/min, sample volume 40 microl. In given conditions, the retention time of ciklodol is 6.005min and diprazine 7.227min. Developed method of simultaneous determination and separation of ciklodol and diprazine in respective mixtures could be successfully applied as in the pharmaceutical, as well in the chemical-toxicological laboratories.

  17. Simultaneous High Performance Liquid Chromatography Assay of Pentoxifylline, Mupirocin, Itraconazole, and Fluticasone Propionate in Humco™ Lavare Wound Base

    Directory of Open Access Journals (Sweden)

    Troy Purvis

    2015-11-01

    Full Text Available This article details the elements used in the method verification for the simultaneous high performance liquid chromatography (HPLC assay of Pentoxifylline, Mupirocin, Itraconazole, and Fluticasone Propionate in Humco™ Lavare Wound base. The method was proven to be linear over 50%–150% of the nominal concentration of the standards. The method was proven to be accurate over 50%–150%, with 98%–102% recovery of the actives from spiked placeboes over that range. The method was shown to be specific to the analytes listed and precise, yielding acceptable results for system reproducibility and method repeatability. The method, as written, is considered to have been verified.

  18. High-performance liquid chromatography analysis methods developed for quantifying enzymatic esterification of flavonoids in ionic liquids

    DEFF Research Database (Denmark)

    Lue, Bena-Marie; Guo, Zheng; Xu, X.B.

    2008-01-01

    Methods using reversed-phase high-performance liquid chromatography (RP-HPLC) with ELSD were investigated to quantify enzymatic reactions of flavonoids with fatty acids in the presence of diverse room temperature ionic liquids (RTILs). A buffered salt (preferably triethylamine-acetate) was found ...

  19. Simultaneous analysis for water- and fat-soluble vitamins by a novel single chromatography technique unifying supercritical fluid chromatography and liquid chromatography.

    Science.gov (United States)

    Taguchi, Kaori; Fukusaki, Eiichiro; Bamba, Takeshi

    2014-10-03

    Chromatography techniques usually use a single state in the mobile phase, such as liquid, gas, or supercritical fluid. Chromatographers manage one of these techniques for their purpose but are sometimes required to use multiple methods, or even worse, multiple techniques when the target compounds have a wide range of chemical properties. To overcome this challenge, we developed a single method covering a diverse compound range by means of a "unified" chromatography which completely bridges supercritical fluid chromatography and liquid chromatography. In our method, the phase state was continuously changed in the following order; supercritical, subcritical and liquid. Moreover, the gradient of the mobile phase starting at almost 100% CO2 was replaced with 100% methanol at the end completely. As a result, this approach achieved further extension of the polarity range of the mobile phase in a single run, and successfully enabled the simultaneous analysis of fat- and water-soluble vitamins with a wide logP range of -2.11 to 10.12. Furthermore, the 17 vitamins were exceptionally separated in 4min. Our results indicated that the use of dense CO2 and the replacement of CO2 by methanol are practical approaches in unified chromatography covering diverse compounds. Additionally, this is a first report to apply the novel approach to unified chromatography, and can open another door for diverse compound analysis in a single chromatographic technique with single injection, single column and single system.

  20. A simple liquid extraction protocol for overcoming the ion suppression of triacylglycerols by phospholipids in liquid chromatography mass spectrometry studies.

    Science.gov (United States)

    Araujo, Pedro; Tilahun, Ephrem; Breivik, Joar Fjørtoft; Abdulkader, Bashir M; Frøyland, Livar; Zeng, Yingxu

    2016-02-01

    It is well-known that triacylglycerol (TAG) ions are suppressed by phospholipid (PL) ions in regiospecific analysis of TAG by mass spectrometry (MS). Hence, it is essential to remove the PL during sample preparation prior to MS analysis. The present article proposes a cost-effective liquid-liquid extraction (LLE) method to remove PL from TAG in different kinds of biological samples by using methanol, hexane and water. High performance thin layer chromatography confirmed the lack of PL in krill oil and salmon liver samples, submitted to the proposed LLE protocol, and liquid chromatography tandem MS confirmed that the identified TAG ions were highly enhanced after implementing the LLE procedure.

  1. Electrochemically modulated liquid chromatography: Theoretical investigations and applications from the perspectives of chromatography and interfacial electrochemistry

    Energy Technology Data Exchange (ETDEWEB)

    Keller, David W.

    2005-05-01

    Electrochemically modulated liquid chromatography (EMLC) employs a conductive material as both a stationary phase for chromatographic separations and as a working electrode for performing electrochemistry experiments. This dual functionality gives EMLC the capacity to manipulate chromatographic separations by changing the potential applied (E{sub app}) to the stationary phase with respect to an external reference. The ability to monitor retention as a function of E{sub app} provides a means to chromatographically monitor electrosorption processes at solid-liquid interfaces. In this dissertation, the retention mechanism for EMLC is examined from the perspective of electrical double layer theory and interfacial thermodynamics. From the chromatographic data, it is possible to determine the interfacial excess ({Lambda}) of a solute and changes in interfacial tension (d{gamma}) as a function of both E{sub app} and the supporting electrolyte concentration. Taken together, these two experimentally manipulated parameters can be examined within the context of the Gibbs adsorption equation to delineate the contribution of a variety of interfacial properties, including the charge of solute on the stationary phase and the potential of zero charge (PZC), to the mechanism behind EMLC-based retention. The chromatographic probing of interfacial phenomena is complemented by electroanalytical experiments that exploit the ability to monitor the electronic current flowing through an EMLC column. Cyclic voltammetry and chronoamperometry of an EMLC column are used to determine the electronic performance characteristics of an EMLC column. An electrochemical flow injection analysis of a column is provided in which the current required to maintain a constant E{sub app} is monitored and provides a way to examine the influence that acetonitrile and supporting electrolyte composition, flow rate, column backpressure, and ionic strength have on the structure of electrified interfaces.

  2. Electrochemically modulated liquid chromatography: Theoretical investigations and applications from the perspectives of chromatography and interfacial electrochemistry

    Energy Technology Data Exchange (ETDEWEB)

    Keller, David W. [Iowa State Univ., Ames, IA (United States)

    2005-01-01

    Electrochemically modulated liquid chromatography (EMLC) employs a conductive material as both a stationary phase for chromatographic separations and as a working electrode for performing electrochemistry experiments. This dual functionality gives EMLC the capacity to manipulate chromatographic separations by changing the potential applied (Eapp) to the stationary phase with respect to an external reference. The ability to monitor retention as a function of Eapp provides a means to chromatographically monitor electrosorption processes at solid-liquid interfaces. In this dissertation, the retention mechanism for EMLC is examined from the perspective of electrical double layer theory and interfacial thermodynamics. From the chromatographic data, it is possible to determine the interfacial excess (Λ) of a solute and changes in interfacial tension (dγ) as a function of both Eapp and the supporting electrolyte concentration. Taken together, these two experimentally manipulated parameters can be examined within the context of the Gibbs adsorption equation to delineate the contribution of a variety of interfacial properties, including the charge of solute on the stationary phase and the potential of zero charge (PZC), to the mechanism behind EMLC-based retention. The chromatographic probing of interfacial phenomena is complemented by electroanalytical experiments that exploit the ability to monitor the electronic current flowing through an EMLC column. Cyclic voltammetry and chronoamperometry of an EMLC column are used to determine the electronic performance characteristics of an EMLC column. An electrochemical flow injection analysis of a column is provided in which the current required to maintain a constant Eapp is monitored and provides a way to examine the influence that acetonitrile and supporting electrolyte composition, flow rate, column backpressure, and ionic strength have on the structure of electrified interfaces.

  3. Application of High Performance Liquid Chromatography to Separation of Novel Chiral Tetrahedral Heterometal Clusters

    Institute of Scientific and Technical Information of China (English)

    Xin Yi ZHU; Wei Qiang ZHANG; Yu Hua ZHANG; Li Ren CHEN; Yong Min LI

    2003-01-01

    A series of novel chiral tetrahedral heterometal clusters have firstly been separated oncellulose tris-(3,5-dimethylphenylcarbamate) stationary phase by high performance liquid chrom-atography, using hexane as the mobile phase with various alcohols as modifiers.

  4. Determination of Aspartame, Caffeine, Saccharin, and Benzoic Acid in Beverages by High Performance Liquid Chromatography.

    Science.gov (United States)

    Delaney, Michael F.; And Others

    1985-01-01

    Describes a simple and reliable new quantitative analysis experiment using liquid chromatography for the determinaiton of caffeine, saccharin, and sodium benzoate in beverages. Background information, procedures used, and typical results obtained are provided. (JN)

  5. Determination of maduramicin in feedingstuffs and premixtures by liquid chromatography : development, validation and interlaboratory study

    NARCIS (Netherlands)

    Jong, de J.; Stoisser, B.; Wagner, K.; Tomassen, M.J.H.; Driessen, J.J.M.; Hofman, P.; Putzka, H.A.

    2004-01-01

    A reversed-phase liquid chromatography method for determination of maduramicin in feedingstuffs and premixtures was developed, validated, and interlaboratory studied. The extraction solvent was methanol. Maduramicin was detected at 520 nm after postcolumn derivatization with vanillin. Recovery was

  6. Steroid monochloroacetates : Physical-chemical characteristics and use in gas-liquid chromatography

    NARCIS (Netherlands)

    Molen, H.J. van der; Groen, D.; Maas, J.H. van der

    1965-01-01

    Synthesis and physical-chemical characteristics (melting points, infrared-, visible- and ultraviolet spectra, paper-,thin-layer- and gas-liquid Chromatographie behaviour) of monochloroacetate derivatives of steroids representing the androstane-, pregnane-, estrane- and cholestane series are describe

  7. Two-dimensional liquid chromatography and its application in traditional Chinese medicine analysis and metabonomic investigation.

    Science.gov (United States)

    Li, Zheng; Chen, Kai; Guo, Meng-zhe; Tang, Dao-quan

    2016-01-01

    Two-dimensional liquid chromatography has become an attractive analytical tool for the separation of complex samples due to its enhanced selectivity, peak capacity, and resolution compared with one-dimensional liquid chromatography. Recently, more attention has been drawn on the application of this separation technique in studies concerning traditional Chinese medicines, metabonomes, proteomes, and other complex mixtures. In this review, we aim to examine the application of two-dimensional liquid chromatography in traditional Chinese medicine analysis and metabonomic investigation. The classification and evaluation indexes were first introduced. Then, various switching methods were summarized when used in an on-line two-dimensional liquid chromatography system. Finally, the applications of this separation technique in traditional Chinese medicine analysis and metabonomic investigation were discussed on the basis of specific studies.

  8. Two-dimensional liquid chromatography for direct chiral separations: a review.

    Science.gov (United States)

    León-González, María Eugenia; Rosales-Conrado, Noelia; Pérez-Arribas, Luis Vicente; Guillén-Casla, Vanesa

    2014-01-01

    Separation of enantiomers remains a challenge owing to their identical physical and chemical properties in an achiral environment, and research on specialized separation techniques such as multidimensional achiral-chiral liquid chromatography continues to resolve individual enantiomers in complex samples. Recent advances in application of multidimensional liquid chromatography applied to chiral analysis are reviewed. For this reason, benefits of achiral-chiral coupling are shown, with emphasis in applications on biological and pharmaceutical fields as well as pesticide analysis. A description of standard instrumental setup in both heart-cut and comprehensive multidimensional liquid chromatography is shown. The most broadly used chiral stationary phases for multidimensional liquid chromatography are summarized. An extensive overview of different interface designs applied to complex samples is presented.

  9. New methods and materials for solid phase extraction and high performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Dumont, Philip John [Iowa State Univ., Ames, IA (United States)

    1996-04-23

    This paper describes methods for solid phase extraction and high performance liquid chromatography (HPLC). The following are described: Effects of Resin Sulfonation on the Retention of Polar Organic Compounds in Solid Phase Extraction; Ion-Chromatographic Separation of Alkali Metals In Non-Aqueous Solvents; Cation-Exchange Chromatography in Non-Aqueous Solvents; and Silicalite As a Stationary Phase For HPLC.

  10. An efficient hydrophilic interaction liquid chromatography separation of 7 phospholipid classes based on a diol column

    NARCIS (Netherlands)

    Zhu, C.; Dane, A.; Spijksma, G.; Wang, M.; Greef, J. van der; Luo, G.; Hankemeier, T.; Vreeken, R.J.

    2012-01-01

    A hydrophilic interaction liquid chromatography (HILIC) - ion trap mass spectrometry method was developed for separation of a wide range of phospholipids. A diol column which is often used with normal phase chromatography was adapted to separate different phospholipid classes in HILIC mode using a m

  11. [Development of methods for determining acrylamide in food products by gas-liquid chromatography].

    Science.gov (United States)

    Bessonov, V V; Malinkin, A D; Perederiaev, O I; Bogachuk, M N; Volkovich, S V; Medvedev, Iu V

    2011-01-01

    The method of determination of acrylamide in various food (milk powder, potato chips, instant coffee) by gas-liquid chromatography after pre-bromination was developed. Studies have shown the possibility of using bromination of acrylamide to give it the necessary properties for better extraction, purification and detection. Also revealed the possibility of qualitative and quantitative determine a acrylamide in food by gas-liquid chromatography with detection by electron capture detector.

  12. Liquid chromatography-mass spectrometry coupling by the intermediary of a liquid micro chromatography-electro spray interface; Couplage chromatographie liquide-spectrometrie de masse par l`intermediaire d`une interface electrospray-microchromatographie liquide

    Energy Technology Data Exchange (ETDEWEB)

    Gillard Factor, C.

    1996-12-06

    The objective of this work is to realize a liquid chromatography- mass spectrometry coupling by the intermediary of an electro spray interface and the evaluation of performances of tis analytical tool to study pollutants in water, and more particularly pesticides whom maximum admissible concentration in a table water is 0.1{mu}g/l. This study has allowed to bring to the fore the interest of the ionization mode by electro spray in a LC/MS coupling to identify and quantify pesticides in the state of traces without treating the sample. Then, it was demonstrated the usefulness of this analytical tool to detect high molecular masses molecules. (N.C.)

  13. Liquid chromatography method to determine polyamines in thermosetting polymers

    Energy Technology Data Exchange (ETDEWEB)

    Dopico-Garcia, M.S. [Laboratorio de Quimica - Centro de Investigacions Tecnoloxicas, Universidade da Coruna, Campus de Esteiro s/n, 15403 Ferrol (Spain); Centro Galego do Plastico, A Cabana s/n, 15590 Ferrol (Spain); Lopez-Vilarino, J.M. [Laboratorio de Quimica - Centro de Investigacions Tecnoloxicas, Universidade da Coruna, Campus de Esteiro s/n, 15403 Ferrol (Spain); Fernandez-Martinez, G. [Unidad de Tecnicas Cromatograficas, Servizos de Apoio a Investigacion, Edificio Servizos Centrais de Investigacion, Universidade da Coruna, Campus de Elvina s/n, 15071 A Coruna (Spain); Gonzalez-Rodriguez, M.V., E-mail: victoria@udc.es [Dpto. de Quimica Analitica - E.U. Politecnica, Universidade da Coruna, Avda. 19 de Febrero s/n, 15405 Ferrol (Spain)

    2010-05-14

    A simple, robust and sensitive analytical method to determine three polyamines commonly used as hardeners in epoxy resin systems and in the manufacture of polyurethane is reported. The studied polyamines are: one tetramine, TETA (triethylenetetramine), and two diamines, IPDA (Isophorone diamine) and TCD-diamine (4,7-methano-1H-indene-5,?-dimethanamine, octahydro-). The latter has an incompletely defined structure, and, as far as we know, has not been previously determined by other methods. All three polyamines contain primary amines; TETA also contains secondary amines. The analytical method involves derivatization with 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate, used for the first time for these compounds, followed by high performance liquid chromatography (HPLC) analysis with a fluorescence (FL) detector ({lambda} excitation 248 nm, {lambda} emision 395 nm). The HPLC-DAD-LTQ Orbitrap MS was used in order to provide structural information about the obtained derivatized compounds. The hybrid linear ion trap LTQ Orbitrap mass spectrometer has been introduced in recent years and provides a high mass accuracy. The structures of the derivatized analytes were identified from the protonated molecular ions [M+H]{sup +} and corresponded to the fully labelled analytes. The following analytical parameters were determined for the method using the HPLC-FL: linearity, precision (2.5-10%), instrumental precision intraday (0.8-1.5%) and interday (2.9-6.3%), and detection limits (0.02-0.14 mg L{sup -1}). The stability of stock solutions and derivatized compounds was also investigated. The method was applied to determine the amine free content in epoxy resin dust collected in workplaces.

  14. Liquid Chromatography for Analysis of Metformin in Myrmeleon sp.

    Directory of Open Access Journals (Sweden)

    Afidatul Muadifah

    2017-09-01

    Full Text Available Myrmeleon sp is a typical of insect larva which has been used in Indonesia for diabetes treatment. However, there is no sufficient scientific report explaining the bioactive compounds in this insect. Based on our preliminary research, this insect contained metformin, i.e. one of bioactive compounds for the treatment of type-2 diabetes. Therefore, this study is focused on the development of separation technique using high performance liquid chromatography (HPLC on a reverse phase C-18 column with UV detection to identify and quantify metformin in methanol extract of Myrmeleon sp. Several parameters of HPLC method were optimized with respect to high resolution of separation and accurate determination of metformin. Satisfied separation was obtained under gradient elution mode using aqueous methanol mobile phase varied from 50-90 % of methanol with flow rate of 0.5 mL/min and detection wavelength of 233 nm. The method performed total separation for all compounds in less than 11 minutes. Spiking technique was chosen for metformin identification and quantitation. Metformin in extract Myrmeleon sp was eluted at retention time (tR of 4.095 minutes, similarly with retention time of standard metformin of 4.092 minutes. The quantity of metformin in Myrmeleon sp can be simply determined by comparing the additional area of standard metformin with area of metformin from extract Myrmeleon sp. The results confirmed that methanol extract of Myrmeleon sp contained anti-diabetes compound of metformin of 0.58 mg/g Myrmeleon sp larvae with acceptable coefficient variation of 5.56 %.

  15. Tryptophan and kynurenine determination in human hair by liquid chromatography.

    Science.gov (United States)

    Dario, Michelli F; Freire, Thamires Batello; Pinto, Claudinéia Aparecida Sales de Oliveira; Prado, María Segunda Aurora; Baby, André R; Velasco, Maria Valéria R

    2017-09-18

    Tryptophan, an amino acid found in hair proteinaceous structure is used as a marker of hair photodegradation. Also, protein loss caused by several chemical/physical treatments can be inferred by tryptophan quantification. Kynurenine is a photo-oxidation product of tryptophan, expected to be detected when hair is exposed mainly to UVB (290-320nm) radiation range. Tryptophan from hair is usually quantified directly as a solid or after alkaline hydrolysis, spectrofluorimetrically. However, these types of measure are not sufficiently specific and present several interfering substances. Thus, this work aimed to propose a quantification method for both tryptophan and kynurenine in hair samples, after alkali hydrolysis process, by using high-performance liquid chromatography (HPLC) with fluorimetric and UV detection. The tryptophan and kynurenine quantification method was developed and validated. Black, white, bleached and dyed (blond and auburn) hair tresses were used in this study. Tryptophan and kynurenine were separated within ∼9min by HPLC. Both black and white virgin hair samples presented similar concentrations of tryptophan, while bleaching caused a reduction in the tryptophan content as well as dyeing process. Unexpectedly, UV/vis radiation did not promote significantly the conversion of tryptophan into its photo-oxidation product and consequently, kynurenine was not detected. Thus, this works presented an acceptable method for quantification of tryptophan and its photooxidation metabolite kynurenine in hair samples. Also, the results indicated that bleaching and dyeing processes promoted protein/amino acids loss but tryptophan is not extensively degraded in human hair by solar radiation. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Novel liquid chromatography tandem mass spectrometry (LC-MS/MS) methods for measuring steroids.

    Science.gov (United States)

    Keevil, Brian G

    2013-10-01

    Liquid chromatography tandem mass spectrometry (LC-MS/MS) is increasingly becoming the method of choice for steroid hormone measurements due to small sample volumes, fast analysis times and improved specificity compared to immunoassays. Achievement of demanding analytical targets for steroid analysis is now becoming possible because of improvements in sample preparation technology, liquid chromatography column technology and mass spectrometer design. The most popular sample treatment strategies comprise protein precipitation (PP), solid-phase extraction (SLE) and liquid-liquid extraction (LLE). Modern liquid chromatography columns can ensure the adequate separation of isobaric compounds e.g. 21 Deoxycortisol, 11 Deoxycortisol and Corticosterone. The most appropriate method may be chosen to improve assay sensitivity by reducing matrix effects (LLE, SPE) or simplicity and speed (PP). Specific examples of some clinically important steroids including oestradiol, aldosterone, renin, serum cortisol, salivary cortisol and salivary testosterone will be described.

  17. Analysis of global components in Ganoderma using liquid chromatography system with multiple columns and detectors.

    Science.gov (United States)

    Qian, Zhengming; Zhao, Jing; Li, Deqiang; Hu, Dejun; Li, Shaoping

    2012-10-01

    In present study, a multiple columns and detectors liquid chromatography system for analysis of global components in traditional Chinese medicines was developed. The liquid chromatography system was consist of three columns, including size exclusion chromatography column, hydrophilic interaction chromatography column, and reversed phase chromatography column, and three detectors, such as diode array detector, evaporative light scattering detector, and mass spectrometry detector, based on column switching technique. The developed multiple columns and detectors liquid chromatography system was successfully applied to the analysis of global components, including macromolecular (polysaccharides), high (nucleosides and sugars)-, and low (triterpenes)-polarity small molecular compounds in Ganoderma, a well-known Chinese medicinal mushroom. As a result, one macromolecular chromatographic peak was found in two Ganoderma species, 19 components were identified in Ganoderma lucidum (two sugars, three nucleosides, and 14 triterpenes), and four components (two sugars and two nucleosides) were identified in Ganoderma sinense. The developed multiple columns and detectors liquid chromatography system was helpful to understand comprehensive chemical characters in TCMs.

  18. Determination of dodecylbenzenesulphonates and ethoxylated alkylphenols in liquid pesticide formulations by high-performance liquid chromatography.

    Science.gov (United States)

    Schreuder, R H; Martijn, A

    1988-01-01

    A method is presented for determining mixtures of calcium dodecylbenzene-sulphonate (CaDBS) and ethoxylated alkylphenols in pesticidal emulsifiable concentrates. The pesticide formulations are adsorbed on a pre-concentration column. The active ingredients, the solvents and the emulsifiers are eluted successively by using solvents with increasing polarities. The various homologues of CaDBS and the ethoxylated alkylphenols are separated by reversed-phase high performance liquid chromatography using methanol-water containing tetramethylammonium bromide. The oligomers of the ethoxylated phenols are separated on an aminopropyl-modified column using a solvent gradient (propan-2-ol-water and hexane-tetrahydrofuran). Quantitative results are given for synthetic samples. The degree of ethoxylation of the ethoxylated alkylphenols has been determined and the CaDBS components characterized.

  19. Isolation and purification of uremic middle molecules by multi-step liquid chromatography

    Institute of Scientific and Technical Information of China (English)

    储结根; 何炳林; 刘晓航; 袁直

    2002-01-01

    Isolation and comparison of uremic sera and urine and normal sera and urine were performed by gel permeation chromatography, anion exchange chromatography and re-versed-phase high performance liquid chromatography. Two uremic middle molecular fractions (A and B) were obtained from uremic sera and urine and normal urine by gel permeation chromatography, but not from normal sera. The anion exchange chromatographic results of fraction A from different origins demonstrate that subfraction A-3 could be excreted in urine by healthy subject, but accumulated in uremic serum for renal failure of patient with uremia. After desalinization subfraction A-3 was analyzed by MALDI-TOF-MS. The results show that subfraction A-3 consists of six compounds with molecular weight 839, 873, 1007.94, 1106, 1680 and 2015 respectively. Finally, by reversed-phase high performance liquid chromatography, subfraction A-3 was further resolved into six independent fractions. Thus, the isolation and purification of six middle molecular c

  20. Evaluation of a silicon oxynitride hydrophilic interaction liquid chromatography column in saccharide and glycoside separations.

    Science.gov (United States)

    Wan, Huihui; Sheng, Qianying; Zhong, Hongmin; Guo, Xiujie; Fu, Qing; Liu, Yanfang; Xue, Xingya; Liang, Xinmiao

    2015-05-01

    The retention characteristics of a silicon oxynitride stationary phase for carbohydrate separation were studied in hydrophilic interaction chromatography mode. Four saccharides including mono-, di-, and trisaccharides were employed to investigate the effects of water content and buffer concentration in the mobile phase on hydrophilic interaction liquid chromatography retention. For the tested saccharides, the silicon oxynitride column demonstrated excellent performance in terms of separation efficiency, hydrophilicity, and interesting separation selectivity for carbohydrates compared to the bare silica stationary phase. Finally, the silicon oxynitride hydrophilic interaction liquid chromatography column was employed in the separation of complex samples of fructooligosaccharides, saponins, and steviol glycoside from natural products. The resulting chromatograms demonstrated good separation efficiency and longer retention compared with silica, which further confirmed the advantages and potential application of silicon oxynitride stationary phase for hydrophilic interaction liquid chromatography separation.

  1. Analysis of microdialysate monoamines, including noradrenaline, dopamine and serotonin, using capillary ultra-high performance liquid chromatography and electrochemical detection.

    Science.gov (United States)

    Ferry, Barbara; Gifu, Elena-Patricia; Sandu, Ioana; Denoroy, Luc; Parrot, Sandrine

    2014-03-01

    Electrochemical methods are very often used to detect catecholamine and indolamine neurotransmitters separated by conventional reverse-phase high performance liquid chromatography (HPLC). The present paper presents the development of a chromatographic method to detect monoamines present in low-volume brain dialysis samples using a capillary column filled with sub-2μm particles. Several parameters (repeatability, linearity, accuracy, limit of detection) for this new ultrahigh performance liquid chromatography (UHPLC) method with electrochemical detection were examined after optimization of the analytical conditions. Noradrenaline, adrenaline, serotonin, dopamine and its metabolite 3-methoxytyramine were separated in 1μL of injected sample volume; they were detected above concentrations of 0.5-1nmol/L, with 2.1-9.5% accuracy and intra-assay repeatability equal to or less than 6%. The final method was applied to very low volume dialysates from rat brain containing monoamine traces. The study demonstrates that capillary UHPLC with electrochemical detection is suitable for monitoring dialysate monoamines collected at high sampling rate.

  2. Characterization of hydroxypropylmethylcellulose (HPMC) using comprehensive two-dimensional liquid chromatography

    NARCIS (Netherlands)

    Greiderer, A.; Steeneken, L.; Aalbers, T.; Vivó-Truyols, G.; Schoenmakers, P.

    2011-01-01

    Various hydroxyl-propylmethylcellulose (HPMC) polymers were characterized according to size and compositional distributions (percentage of methoxyl and hydroxyl-propoxyl substitution) by means of comprehensive two-dimensional liquid chromatography (LC × LC) using reversed-phase (RP) liquid chromatog

  3. STRUCTURAL CHARACTERIZATION OF THE DECOMPOSITION PRODUCTS OF SALBUTAMOL BY LIQUID-CHROMATOGRAPHY IONSPRAY MASS-SPECTROMETRY

    NARCIS (Netherlands)

    MALKKILAINE, L; BRUINS, AP

    1994-01-01

    Liquid chromatography-ionspray mass spectrometry was used to elucidate the structures of the decomposition products of salbutamol. The best sensitivity in mass spectrometry was achieved by using a mixture of acetonitrile and ammonium formate (10 mM, pH 3.3) as the mobile phase in liquid chromatograp

  4. Dispersive Liquid-Liquid Microextraction and determination of Platinum(IV by High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Ali Mazloomifar

    2015-09-01

    Full Text Available A simple, rapid, and efficient procedure, dispersive liquid-liquid microextraction (DLLME, has been developed for the extraction and preconcentration of platinum (IV in environmental water samples. The factors relevant to the microextraction efficiency, such as the kind and volume of extraction and dispersive solvent, the extraction time, the pH in aqueous, and the salt effect, were optimized. Under the optimum conditions , the enrichment factor of this method for platinum was reached at 119. The detection limit for platinum was 0.3 ng mL-1 , and the relative standard deviation (RSD was 0.42% (n = 10 , C = 10 ng mL-1. The method was successfully applied to the determination of trace amounts of platinum in environmental water samples.

  5. Quantitative characterization of solid epoxy resins using comprehensive two dimensional liquid chromatography coupled with electrospray ionization-time of flight mass spectrometry.

    Science.gov (United States)

    Julka, Samir; Cortes, Hernan; Harfmann, Robert; Bell, Bruce; Schweizer-Theobaldt, Andreas; Pursch, Matthias; Mondello, Luigi; Maynard, Shawn; West, David

    2009-06-01

    A comprehensive multidimensional liquid chromatography system coupled to Electrospray Ionization-Mass Spectrometry (LCxLC-ESI-MS) was developed for detailed characterization and quantitation of solid epoxy resin components. The two orthogonal modes of separation selected were size exclusion chromatography (SEC) in the first dimension and liquid chromatography at critical conditions (LCCC) in the second dimension. Different components present in the solid epoxy resins were separated and quantitated for the first time based on the functional groups and molecular weight heterogeneity. Coupling LCxLC separations with mass spectrometry enabled the identification of components resolved in the two-dimensional space. Several different functional group families of compounds were separated and identified, including epoxy-epoxy and epoxy-alpha-glycol functional oligomers, and their individual molecular weight ranges were determined. Repeatability obtained ranged from 0.5% for the main product to 21% for oligomers at the 0.4% concentration level.

  6. Chromatography.

    Science.gov (United States)

    Brantley, L. Reed, Sr.; Demanche, Edna L.; Klemm, E. Barbara; Kyselka, Will; Phillips, Edwin A.; Pottenger, Francis M.; Yamamoto, Karen N.; Young, Donald B.

    This booklet presents some activities on chromatography. Directions for preparing leaf pigment extracts using alcohol are given, and paper chromatography and thin-layer chromatography are described as modifications of the basic principles of chromatography. (KHR)

  7. Chromatography.

    Science.gov (United States)

    Brantley, L. Reed, Sr.; Demanche, Edna L.; Klemm, E. Barbara; Kyselka, Will; Phillips, Edwin A.; Pottenger, Francis M.; Yamamoto, Karen N.; Young, Donald B.

    This booklet presents some activities on chromatography. Directions for preparing leaf pigment extracts using alcohol are given, and paper chromatography and thin-layer chromatography are described as modifications of the basic principles of chromatography. (KHR)

  8. Preparation and evaluation of surface-bonded tricationic ionic liquid silica as stationary phases for high-performance liquid chromatography.

    Science.gov (United States)

    Qiao, Lizhen; Shi, Xianzhe; Lu, Xin; Xu, Guowang

    2015-05-29

    Two tricationic ionic liquids were prepared and then bonded onto the surface of supporting silica materials through "thiol-ene" click chemistry as new stationary phases for high-performance liquid chromatography. The obtained columns of tricationic ionic liquids were evaluated respectively in the reversed-phase liquid chromatography (RPLC) mode and hydrophilic interaction liquid chromatography (HILIC) mode, and possess ideal column efficiency of 80,000 plates/m in the RPLC mode with naphthalene as the test solute. The tricationic ionic liquid stationary phases exhibit good hydrophobic and shape selectivity to hydrophobic compounds, and RPLC retention behavior with multiple interactions. In the HILIC mode, the retention and selectivity were evaluated through the efficient separation of nucleosides and bases as well as flavonoids, and the typical HILIC retention behavior was demonstrated by investigating retention changes of hydrophilic solutes with water volume fraction in mobile phase. The results show that the tricationic ionic liquid columns possess great prospect for applications in analysis of hydrophobic and hydrophilic samples.

  9. Supercritical Fluid Chromatography, Pressurized Liquid Extraction and Supercritical Fluid Extraction

    Energy Technology Data Exchange (ETDEWEB)

    Henry, Matthew C.; Yonker, Clement R.

    2006-06-15

    In this review we examine the related fields of supercritical fluid chromatography (SFC) and supercritical fluid extraction (SFE). We reviewed the published literature in the period from November 2003 to November 2005. Well over 300 papers were published in this period. This large body of work indicates continuing active growth of the field, but an exhaustive review is beyond the scope of this work. We have chosen to include a sampling of publications that best represent the continuing trends and new ideas in the field. In keeping with past reviews on this subject1, we have broadened our scope to include fluid systems operating at high temperature and pressure, but below the critical point. Various terms have been applied to this state: sub-critical fluid extraction, pressurized liquid extraction, and accelerated solvent extraction. The term accelerated solvent extraction has been used by instrument manufacturers to refer to this process, but we will use the more descriptive term pressurized liquid extraction (PLE) to refer to these systems. Most of the research in the field is of an “evolutionary” rather than “revolutionary” nature. As in the previous review period, applications papers make up a majority of the published work. Pharmaceutical applications continue to be a strong theme. Most of the pharmaceutical work has centered on preparative, rather than analytical, separations. Chiral separations are an exception, as analytical scale separations of chiral compounds are an area of intense interest. Food and natural products represent the next largest body of work. Major themes are the isolation and characterization of high-value added foodstuffs, fragrances, and flavor compounds from novel natural materials or agricultural by-products. The areas of food, natural products, and pharmaceutical separation science converge in the area of so-called nutraceuticals. These are typically high-value products, either sold alone or as part of a fortified food, that

  10. Crosslinked polymeric ionic liquids as solid-phase microextraction sorbent coatings for high performance liquid chromatography.

    Science.gov (United States)

    Yu, Honglian; Merib, Josias; Anderson, Jared L

    2016-03-18

    Neat crosslinked polymeric ionic liquid (PIL) sorbent coatings for solid-phase microextraction (SPME) compatible with high-performance liquid chromatography (HPLC) are reported for the first time. Six structurally different PILs were crosslinked to nitinol supports and applied for the determination of select pharmaceutical drugs, phenolics, and insecticides. Sampling conditions including sample solution pH, extraction time, desorption solvent, desorption time, and desorption solvent volume were optimized using design of experiment (DOE). The developed PIL sorbent coatings were stable when performing extractions under acidic pH and remained intact in various organic desorption solvents (i.e., methanol, acetonitrile, acetone). The PIL-based sorbent coating polymerized from the IL monomer 1-vinyl-3-(10-hydroxydecyl) imidazolium chloride [VC10OHIM][Cl] and IL crosslinker 1,12-di(3-vinylbenzylimidazolium) dodecane dichloride [(VBIM)2C12] 2[Cl] exhibited superior extraction performance compared to the other studied PILs. The extraction efficiency of pharmaceutical drugs and phenolics increased when the film thickness of the PIL-based sorbent coating was increased while many insecticides were largely unaffected. Satisfactory analytical performance was obtained with limits of detection (LODs) ranging from 0.2 to 2 μg L(-1) for the target analytes. The accuracy of the analytical method was examined by studying the relative recovery of analytes in real water samples, including tap water and lake water, with recoveries varying from 50.2% to 115.9% and from 48.8% to 116.6%, respectively.

  11. Ionic liquids as novel stationary phases in gas liquid chromatography: inverse or normal isotope effect?

    Science.gov (United States)

    Schmarr, Hans-Georg; Slabizki, Petra; Müntnich, Sabrina; Metzger, Carmen; Gracia-Moreno, Elisa

    2012-12-28

    The separation of deuterated and non-deuterated compounds in gas liquid partitioning chromatography (GLC) on silicone type stationary phase usually results in the inverse isotope effect. With ionic liquids (ILs) as stationary phase, however, this may show a totally different nature. The inverse isotope effect, in which heavier (deuterated) isotopic compounds (isotopologues) elute earlier, is to be expected when van der Waals (London) dispersion forces play a dominant role in the solute-stationary phase interaction. Such (apolar) interactions seem to play only a minor role when ILs are the stationary phases, leading to only a marginal inverse isotope effect, e.g. for the separation of 2,4,6-trichloroanisole and its [(2)H(5)]-isotopologue on 1,12-di(tripropylphosphonium) dodecane bis(trifluoromethansulfonyl) amide (commercialized as SLB-IL59, Supelco). Indeed, with the most polar stationary phase available (commercialized as SLB-IL111; Supelco), this separation showed a normal isotope effect. Further examples are presented and the nature of the isotope effect observed is discussed.

  12. Characterization of synthetic dyes by comprehensive two-dimensional liquid chromatography combining ion-exchange chromatography and fast ion-pair reversed-phase chromatography.

    Science.gov (United States)

    Pirok, Bob W J; Knip, Jitske; van Bommel, Maarten R; Schoenmakers, Peter J

    2016-03-04

    In the late 19th century, newly invented synthetic dyes rapidly replaced the natural dyes on the market. The characterization of mixtures of these so-called early synthetic dyes is complicated through the occurrence of many impurities and degradation products. Conventional one-dimensional liquid chromatography does not suffice to obtain fingerprints with sufficient resolution and baseline integrity. Comprehensive two-dimensional liquid chromatography (LC×LC) is employed in this study, with ion-exchange chromatography in the first dimension and fast ion-pair liquid chromatography in the second. Retention in the first dimension is largely determined by the number of charges, while the selection of a small ion-pair reagent (tetramethylammonium hydroxide) in the second dimension causes retention to be largely determined by the molecular structure of the dye. As a result, there is a high degree of orthogonality of the two dimensions, similar to the values typically encountered in GC×GC. The proposed LC×LC method shows a theroretical peak capacity of about 2000 in an analysis time of about three hours. Clear, informative fingerprints are obtained that open a way to a more efficient characterization of dyes used in objects of cultural heritage.

  13. Application of Ionic Liquids in High Performance Reversed-Phase Chromatography

    Science.gov (United States)

    Wang, Ye; Tian, Minglei; Bi, Wentao; Row, Kyung Ho

    2009-01-01

    Ionic liquids, considered “green” chemicals, are widely used in many areas of analytical chemistry due to their unique properties. Recently, ionic liquids have been used as a kind of novel additive in separation and combined with silica to synthesize new stationary phase as separation media. This review will focus on the properties and mechanisms of ionic liquids and their potential applications as mobile phase modifier and surface-bonded stationary phase in reversed-phase high performance liquid chromatography (RP-HPLC). Ionic liquids demonstrate advantages and potential in chromatographic field. PMID:19582220

  14. Application of Ionic Liquids in High Performance Reversed-Phase Chromatography

    Directory of Open Access Journals (Sweden)

    Wentao Bi

    2009-06-01

    Full Text Available Ionic liquids, considered “green” chemicals, are widely used in many areas of analytical chemistry due to their unique properties. Recently, ionic liquids have been used as a kind of novel additive in separation and combined with silica to synthesize new stationary phase as separation media. This review will focus on the properties and mechanisms of ionic liquids and their potential applications as mobile phase modifier and surface-bonded stationary phase in reversed-phase high performance liquid chromatography (RP-HPLC. Ionic liquids demonstrate advantages and potential in chromatographic field.

  15. Partition coefficients of organic compounds in new imidazolium based ionic liquids using inverse gas chromatography.

    Science.gov (United States)

    Revelli, Anne-Laure; Mutelet, Fabrice; Jaubert, Jean-Noël

    2009-06-05

    Partition coefficients of organic compounds in four ionic liquids: 1-ethanol-3-methylimidazolium tetrafluoroborate, 1-ethanol-3-methylimidazolium hexafluorophosphate, 1,3-dimethylimidazolium dimethylphosphate and 1-ethyl-3-methylimidazolium diethylphosphate were measured using inverse gas chromatography from 303.3 to 332.55K. The influence of gas-liquid and gas-solid interfacial adsorption of different solutes on ionic liquids was also studied. Most of the polar solutes were retained largely by partition while light hydrocarbons were retained predominantly by interfacial adsorption on the ionic liquids studied in this work. The solvation characteristics of the ionic liquids were evaluated using the Abraham solvation parameter model.

  16. Using dispersive liquid-liquid microextraction and liquid chromatography for determination of guaifenesin enantiomers in human urine.

    Science.gov (United States)

    Hatami, Mehdi; Farhadi, Khalil; Abdollahpour, Assem

    2011-11-01

    A simple, rapid, and efficient method, dispersive liquid-liquid microextraction (DLLME) coupled with high-performance liquid chromatography-fluorescence detector, has been developed for the determination of guaifenesin (GUA) enantiomers in human urine samples after an oral dose administration of its syrup formulation. Urine samples were collected during the time intervals 0-2, 2-4, and 4-6 h and concentration and ratio of two enantiomers was determined. The ratio of R-(-) to S-(+) enantiomer concentrations in urine showed an increase with time, with R/S ratios of 0.66 at 2 h and 2.23 at 6 h. For microextraction process, a mixture of extraction solvent (dichloromethane, 100 μL) and dispersive solvent (THF, 1 mL) was rapidly injected into 5.0 mL diluted urine sample for the formation of cloudy solution and extraction of enantiomers into the fine droplets of CH(2)Cl(2). After optimization of HPLC enantioselective conditions, some important parameters, such as the kind and volume of extraction and dispersive solvents, extraction time, temperature, pH, and salt effect were optimized for dispersive liquid-liquid microextraction process. Under the optimum extraction condition, the method yields a linear calibration curve in the concentration range from 10 to 2000 ng/mL for target analytes. LOD was 3.00 ng/mL for both of the enantiomers. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Repeating cytological preparations on liquid-based cytology samples: A methodological advantage?

    Science.gov (United States)

    Pinto, Alvaro P; Maia, Henrique Felde; di Loretto, Celso; Krunn, Patrícia; Túlio, Siumara; Collaço, Luis Martins

    2007-10-01

    This study investigates the rule that repeating cytological preparations on liquid-based cytology improves sample adequacy, diagnosis, microbiological, and hormonal evaluations. We reviewed 156 cases of pap-stained preparations of exfoliated cervical cells in two slides processed by DNA-Cytoliq System. After sample repeat/dilution, limiting factors affecting sample adequacy were removed in nine cases and three unsatisfactory cases were reclassified as satisfactory. Diagnosis was altered in 24 cases. Of these, the original diagnosis in 15 was atypical squamous cells of undetermined significance; after the second slide examination, diagnosis in 5 of the 15 cases changed to low-grade squamous intraepithelial lesion, 3 to high-grade squamous intraepithelial lesion, and 7 to absence of lesion. Microbiological evaluation was altered, with Candida sp. detected in two repeated slides. Repeat slide preparation or dilution of residual samples enhances cytological diagnosis and decreases effects of limiting factors in manually processed DIGENE DCS LBC.

  18. Identification of Explosives from Porous Materials: Applications Using Reverse Phase High Performance Liquid Chromatography and Gas Chromatography

    Science.gov (United States)

    Miller, C. J.; Elias, G.; Schmitt, N. C.; Rae, C.

    2010-06-01

    High performance liquid chromatography and gas chromatography techniques are well documented and widely used for the detection of trace explosives from organic solvents. These techniques were modified to identify and quantify explosives extracted from various materials taken from people who had recently handled explosives. Documented techniques were modified to specifically detect and quantify trace levels of the military explosives, RDX, TNT, and PETN from denim, colored flannel, vinyl, and canvas extracted in methanol and filtered using no additional sample cleanup of the sample extract prior to analysis. The filtered methanol extracts were injected directly into several different column types and analyzed by high performance liquid chromatography using ultraviolet detection and/or gas chromatography using electron capture detection. This paper describes general screening methods that were used to determine the presence of explosives (RDX, TNT, and PETN) in unknown samples of denim, colored flannel, vinyl and canvas in addition to techniques that have been optimized for quantification of each explosive from the substrate extracts.

  19. Determination of N-nitrosodiethanolamine in cosmetic products by reversed-phase dispersive liquid-liquid microextraction followed by liquid chromatography.

    Science.gov (United States)

    Chisvert, Alberto; Benedé, Juan L; Peiró, María; Pedrón, Isabel; Salvador, Amparo

    2017-05-01

    A new analytical method for the determination of N-nitrosodiethanolamine (NDELA), a very harmful compound not allowed in cosmetic products, is presented. The method is based on a new approach of dispersive liquid-liquid microextraction (DLLME) useful for extraction of highly polar compounds, called reversed-phase DLLME (RP-DLLME), followed by liquid chromatography-ultraviolet/visible (LC-UV/Vis) determination. The variables involved in the RP-DLLME process were studied to provide the best enrichment factors. Under the optimized conditions, a mixture of 750µL of acetone (disperser solvent) and 125µL of water (extraction solvent) was rapidly injected into 5mL of toluene sample solution. The extracts were injected into the LC-UV/Vis system using ammonium acetate 0.02M as mobile phase. After chromatographic separation, the eluate passed throughout a photolysis unit in order to convert NDELA to nitrite, and then it was merged with a flow stream of Griess Reagent and passed throughout a post-column reactor at 50°C to derivatize nitrite into an azo-dye, which was finally measured spectrophotometrically at 540nm. The method was successfully validated showing good linearity, an enrichment factor of 31.5±0.9, limits of detection and quantification of 1.1 and 3.6ngmL(-1), respectively, and a good repeatability (RSD <8%). Finally, the proposed analytical method was applied to the determination of NDELA in commercial cosmetic samples of different nature, specifically three lipophilic creams and a hydrophilic shower gel, with good relative recovery values (87 - 117%) thus showing that matrix effects are negligible. These results were compared with those obtained by applying the ISO 10130 official method, which uses the same detection approach. It was concluded that a great improvement in the sensitivity was achieved, whereas the use of organochlorine solvents is avoided and therefore it can be considered as a greener approach.

  20. Separation of Nitration By-Products in Commercial-Grade Trinitro-Toluene by High Performance Liquid Chromatography.

    Science.gov (United States)

    1982-06-01

    MRL-TN-464 SEPARATION OF NITRATION BY-PRODUCTS IN COMMERCIAL-GRADE TITR-TOLUENE BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY Peter J. Sanders ABSTRACT...UNCLASSIFIED TITLE SEPARATION OF NITRATION BY-PRODUCTS IN COMMERCIAL-GRADE TRXNITRO-TOLUENE BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY AUTHOR(S...PRODUCTS IN COMMERCIAL-GRADE TRINITRO-TOLUENE BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY 16 INTRODUCTION Fbr some time, a need has existed for the

  1. Analysis of chlorpheniramine in human urine samples using dispersive liquid-liquid microextraction combined with high-performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Mehdi Maham

    2014-09-01

    Full Text Available A simple and environmentally friendly microextraction technique was used for determination of chlorpheniramine (CPM, an antihistamine drug, in human urine samples using dispersive liquid-liquid microextraction (DLLME followed by high performance liquid chromatography with diode array detection (HPLC-DAD. In this extraction technique, an appropriate mixture of acetonitrile (disperser solvent and carbon tetrachloride (extraction solvent was rapidly injected into the urine sample containing the target analyte. Tiny droplets of extractant were formed and dispersed into the sample solution and then sedimented at the bottom of the conical test tube by centrifugation. Under optimal conditions, the calibration curve was linear in the range of 0.055-5.5 µg mL-1, with a detection limit of 16.5 ng mL-1. This proposed method was successfully applied to the analysis of real urine samples. Low consumption of toxic organic solvents, simplicity of operation, low cost and acceptable figures of merit are the main advantages of the proposed technique.

  2. Optimization and Application of Liquid Chromatography Determination of Dispersive Liquid-liquid Microextraction Purified Astaxanthin in Shrimp Waste

    Institute of Scientific and Technical Information of China (English)

    ZHU Tao; ROW Kyung-ho

    2013-01-01

    A new molecularly imprinted solid-phase extraction(MISPE) monolithic cartridge was synthesized,and MISPE-DLLME(DLLME=dispersive liquid-liquid microextraction) was developed for purification of astaxanthin in shrimp waste.The eluent(methanol) from MISPE was used as the dispersive solvent in subsequent DLLME for further purifying and enriching the analyte prior to high-performance liquid chromatography(HPLC) analysis.The mobile phase was methanol-acetonitrile-water-dichloromethane(85:5:5:5,volume ratio),flow rate was 0.7 mL/min and UV wavelength was 476 nm.Under optimal conditions,good linearity was obtained in a range of 0.2-200.0 μg/mL(r2=0.9998) with a limit of detection(LOD) of 0.08 μg/mL,and the extraction recoveries at three spiked levels ranged from 88.3%-92.5% with a relative standard deviation(RSD) less than 4.3%.Moreover,the mean contents of astaxanthin in the three batches of shrimp waste were 95.9,85.4 and 77.2 μg/g,respectively.This method combining the advantages of MISPE and DLLME results in high selectivity and low cost,which was applied to determining the astaxanthin level in shrimp waste samples.

  3. Quality evaluation of moluodan concentrated pill using high-performance liquid chromatography fingerprinting coupled with chemometrics.

    Science.gov (United States)

    Tao, Lingyan; Zhang, Qing; Wu, Yongjiang; Liu, Xuesong

    2016-12-01

    In this study, a fast and effective high-performance liquid chromatography method was developed to obtain a fingerprint chromatogram and quantitative analysis simultaneously of four indexes including gallic acid, chlorogenic acid, albiflorin and paeoniflorin of the traditional Chinese medicine Moluodan Concentrated Pill. The method was performed by using a Waters X-bridge C18 reversed phase column on an Agilent 1200S high-performance liquid chromatography system coupled with diode array detection. The mobile phase of the high-performance liquid chromatography method was composed of 20 mmol/L phosphate solution and acetonitrile with a 1 mL/min eluent velocity, under a detection temperature of 30°C and a UV detection wavelength of 254 nm. After the methodology validation, 16 batches of Moluodan Concentrated Pill were analyzed by this high-performance liquid chromatography method and both qualitative and quantitative evaluation results were achieved by similarity analysis, principal component analysis and hierarchical cluster analysis. The results of these three chemometrics were in good agreement and all indicated that batch 10 and batch 16 showed significant differences with the other 14 batches. This suggested that the developed high-performance liquid chromatography method could be applied in the quality evaluation of Moluodan Concentrated Pill.

  4. Systematic comparison of sensitivity between hydrophilic interaction liquid chromatography and reversed phase liquid chromatography coupled with mass spectrometry.

    Science.gov (United States)

    Periat, Aurélie; Boccard, Julien; Veuthey, Jean-Luc; Rudaz, Serge; Guillarme, Davy

    2013-10-18

    Hydrophilic interaction liquid chromatography (HILIC) appears as a promising strategy to increase sensitivity with electrospray ionization source (ESI/MS). In the present study, peak heights, background noises and signal-to-noise ratios (S/N) obtained with HILIC-MS/MS and RPLC-MS/MS conditions were systematically compared using a dataset of 56 basic drugs possessing diverse physico-chemical properties. Various mobile phase conditions were investigated, including different pH (3 and 6 in HILIC; 3, 6 and 9 in RPLC) and flow rates (300, 600 and 1000μL/min). The average gain in sensitivity obtained between HILIC and RPLC was equal to 7 and 10 at pH 3 and 6, respectively. However, this value was not reliable, since it was altered by a few compounds possessing an "extreme" behaviour (gain in sensitivity from 100-fold to >8000-fold better). Then, the median gain in sensitivity, equal to 4 in our case, whatever the pH, should be considered. For about 90% of the tested compounds and analytical conditions, the best S/N was systematically attained under HILIC mode. Thanks to PCA representation, it was shown that the basic compounds with pKa between 6 and 8 generally had the best sensitivity in HILIC at pH 6, while the best sensitivity for basic analytes possessing pKa higher than 8 was usually obtained in HILIC at pH 3. As previously reported, the sensitivity gain in HILIC vs. RPLC was explained by the difference in acetonitrile concentration at elution (in average 29% ACN in RPLC and 82% ACN in HILIC at pH 6) leading to better analytes' desolvation. However, it seems that this high proportion of solvent also favourably influenced the ionization by modifying pH and pKa. Indeed the weakest bases of our training set of compounds (pKa between 2 and 5) showed an unexpectedly strong gain in sensitivity, between 20 and 100-fold in comparison to RPLC. These results prove that the ionic character of analytes in solution (i.e., pKa and pH) and the ionization mechanism (i.e., proton

  5. A new interface for coupling solid phase microextraction with liquid chromatography.

    Science.gov (United States)

    Chen, Yong; Sidisky, Leonard M

    2014-03-19

    A modified Rheodyne 7520 microsample injector was used as a new solid phase microextraction (SPME)-liquid chromatography (LC) interface. The modification was focused on the construction of a new sample rotor, which was built by gluing two sample rotors together. The new sample rotor was further reinforced with 3 pieces of stainless steel tubing. The enlarged central flow passage in the new sample rotor was used as a desorption chamber. SPME fiber desorption occurred in static mode. But all desorption solvent in the desorption chamber was injected into LC system with the interface. The analytical performance of the interface was evaluated by SPME-LC analysis of PAHs in water. At least 90% polycyclic aromatic hydrocarbons (PAHs) were desorbed from a polyacrylonitrile (PAN)/C18 bonded fuse silica fiber in 30s. And injection was completed in 20s. About 10-20% total carryovers were found on the fiber and in the interface. The carryover in the interface was eliminated by flushing the desorption chamber with acetonitrile at 1mL min(-1) for 2min. The repeatability of the method was from 2% to 8%. The limit of detection (LOD) was in the mid pg mL(-1) range. The linear ranges were from 0.1 to 100ng mL(-1). The new SPME-LC interface was reliable for coupling SPME with LC for both qualitative and quantitative analysis.

  6. Determination of polyphenolic compounds by liquid chromatography-mass spectrometry in Thymus species.

    Science.gov (United States)

    Boros, Borbála; Jakabová, Silvia; Dörnyei, Agnes; Horváth, Györgyi; Pluhár, Zsuzsanna; Kilár, Ferenc; Felinger, Attila

    2010-12-17

    Polyphenolic compounds represent a wide group of phytochemicals, including well-known subgroups of phenolic acids, flavonoids, natural dyes, lignans etc., which are produced by plants. These natural bioactive compounds possess a variety of beneficial effects including antioxidant and anticarcinogenic activities, protection against coronary diseases as well as antimicrobial properties. Thymus species have already been reported as sources of different phenolic acids and flavonoids. Moreover, the composition and content of flavonoids in Thymus species play important role as taxonomic markers providing distinction of species. High-performance liquid chromatography (HPLC) coupled with diode array detector (DAD) and on-line mass spectrometry (ESI-MS) method was used for analysis. The method was evaluated for a number of validation characteristics (repeatability and intermediate precision, LOD, LOQ, calibration range, and recovery). The polyphenolic pattern of five native Hungarian Thymus species (T. glabrescens Willd., T. pannonicus All., T. praecox Opiz, T. pulegioides L., and T. serpyllum L.) was characterized. The dominant compound was rosmarinic acid, which ranged between 83.49 μg g(-1) and 1.436 mg g(-1). Other phenolic acids (ferulic acid, caffeic acid and its other derivatives, chlorogenic acid and p-coumaric acids) were present in every examined Thymus species, as well as flavanones: naringenin, eriodictyol and dihydroquercetin; flavones: apigenin and apigenin-7-glucoside, flavonols: quercetin and rutin. The polyphenolic pattern was found to be a useful additional chemotaxonomic tool for classification purposes and determination of the locality of origin.

  7. Analysis of plant nucleotide sugars by hydrophilic interaction liquid chromatography and tandem mass spectrometry.

    Science.gov (United States)

    Ito, Jun; Herter, Thomas; Baidoo, Edward E K; Lao, Jeemeng; Vega-Sánchez, Miguel E; Michelle Smith-Moritz, A; Adams, Paul D; Keasling, Jay D; Usadel, Björn; Petzold, Christopher J; Heazlewood, Joshua L

    2014-03-01

    Understanding the intricate metabolic processes involved in plant cell wall biosynthesis is limited by difficulties in performing sensitive quantification of many involved compounds. Hydrophilic interaction liquid chromatography is a useful technique for the analysis of hydrophilic metabolites from complex biological extracts and forms the basis of this method to quantify plant cell wall precursors. A zwitterionic silica-based stationary phase has been used to separate hydrophilic nucleotide sugars involved in cell wall biosynthesis from milligram amounts of leaf tissue. A tandem mass spectrometry operating in selected reaction monitoring mode was used to quantify nucleotide sugars. This method was highly repeatable and quantified 12 nucleotide sugars at low femtomole quantities, with linear responses up to four orders of magnitude to several 100pmol. The method was also successfully applied to the analysis of purified leaf extracts from two model plant species with variations in their cell wall sugar compositions and indicated significant differences in the levels of 6 out of 12 nucleotide sugars. The plant nucleotide sugar extraction procedure was demonstrated to have good recovery rates with minimal matrix effects. The approach results in a significant improvement in sensitivity when applied to plant samples over currently employed techniques.

  8. Determination of Benzalkonium Chloride in Nasal Drops by High-Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Danijela A. Kostić

    2012-01-01

    Full Text Available A high-performance liquid chromatography (HPLC system was used in the reversed phase mode for the determination of benzalkonium chloride (BKC in nosal drops. A Chromolit RP-18e, 100 x 4.6, (UM6077/035 column was used at 40 °C. The mobile phase, optimized through an experimental design, was a 70:30 (v/v mixture of 0.057M Na-heksansulphonate potassium, dihydrogen orthophosphate buffer (pH 2.9 and acetonitrile, pumped at a flow rate of 1.75 mL/min at maintaining column temperature at 40 °C. Maximum UV detection was achieved at 215 nm. The method was validated in terms of selectivity, linearity, repeatability, precision and accuracy. The method was successfully applied for the determination of BKC in a pharmaceutical formulation of nasal drop solution without any interference from common excipients and drug substance. All the validation parameters were within the acceptance range, concordant to ICH guidelines.

  9. Amphenicols stability in medicated feed – development and validation of liquid chromatography method

    Directory of Open Access Journals (Sweden)

    Pietro Wojciech Jerzy

    2014-12-01

    Full Text Available A liquid chromatography-ultraviolet detection method for the determination of florfenicol (FF and thiamphenicol (TAP in feeds is presented. The method comprises the extraction of analytes from the matrix with a mixture of methanol and acetonitrile, drying of the extract, and its dissolution in phosphate buffer. The analysis was performed with a gradient programme of the mobile phase composed of acetonitrile and buffer (pH = 7.3 on a Zorbax Eclipse Plus C18 (150 × 4.6 mm, 5 μm analytical column with UV (λ = 220 nm detection. The analytical procedure has been successfully adopted and validated for quantitative determination of florfenicol and thiamphenicol in feed samples. Sensitivity, specificity, linearity, repeatability, and intralaboratory reproducibility were included in the validation. The mean recovery of amphenicols was 93.5% within the working range of 50-4000 mg/kg. Simultaneous determination of chloramphenicol, which is banned in the feed, was also included within the same procedure of FF and TAP stability studies. Storing the medicated feed at room temperature for up to one month decreased concentration in the investigated drugs even by 45%. These findings are relevant to successful provision of therapy to animals.

  10. Simultaneous characterization and quantification of 17 main compounds in Rabdosia rubescens by high performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Sen Guo

    2017-04-01

    Full Text Available Rabdosia rubescens is a healthy herbal tea and well-known Chinese medicinal herb. To evaluate the quality of R. rubescens from China, a high performance liquid chromatography method with dual-wavelength detection was developed and validated. The method was successfully applied for the simultaneous characterization and quantification of 17 main constituents from four different cultivation regions in China. Under optimal conditions, analysis was performed on a Luna C-18 column and gradient elution with a solvent system of acetonitrile and 0.5% (v/v acetic acid–water at a flow rate of 1.0 mL/min and wavelength of 220 nm and 280 nm. All standard calibration curves exhibited good linearity (r2 > 0.9992 within the test ranges. The precision was evaluated by intraday and interday tests, which revealed relative standard deviation values within the ranges of 0.57–2.35% and 0.52–3.40%, respectively. The recoveries were in the range of 96.37–101.66%. The relative standard deviation values for stability and repeatability were < 5%. The contents of some compounds were low and varied with different cultivars. The proposed method could serve as a prerequisite for quality control of R. rubescens materials and products.

  11. Determination of folates in seaweeds by high-performance liquid chromatography.

    Science.gov (United States)

    Rodríguez-Bernaldo de Quirós, A; Castro de Ron, C; López-Hernández, J; Lage-Yusty, M A

    2004-04-02

    A reversed-phase high-performance liquid chromatography (HPLC) method, with a combination of fluorescence and ultraviolet detectors, to determine the folate forms present in commercial macroalgae products form northwest Spain as part of nutritional studies in dehydrated and canned seaweeds is reported. The method includes extraction of folates from seaweed by heat treatment, deconjugation of folate polyglutamates by incubation with hog kidney conjugase and purification by solid-phase extraction (SPE) with strong anion-exchange (SAX) cartridges. Separation was achieved with a Tracer Extrasil ODS 5 microm 25 cm x 0.4 cm column using acetonitrile and potassium phosphate buffer (pH 2.21 as mobile phase. Good results were obtained with respect to repeatability (relative standard deviation (R.S.D.) or = 90.80%). The amount of folate (as folic acid) in the six species ranged from 61.4 to 161.6 microg per 100 g dry mass. In all the seaweeds studied (Himanthalia elongata, Laminaria ochroleuca, Palmaria spp., Undaria pinnatifida and Porphyra spp. and Saccorhiza polychides) the single most abundant form is 5-CH3-H4-folate, except Porphyra and Himanthalia.

  12. Simultaneous determination of eleven characteristic lignans in Schisandra chinensis by high-performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Junyang Hu

    2013-01-01

    Full Text Available Background: Schisandra chinensis, one of the well-known traditional Chinese herbal medicines, is derived from the dry ripe fruits of Schisandra chinensis (Turcz. Baill. according to the 9th China Pharmacopeia. Lignans are the main components isolated from extracts of S. chinensis and their content varies depending on where S. chinensis was collected. We have established a qualitative and quantitative method based on the bioactive lignans for control of the quality of S. chinensis from different sources. Materials and Methods: To develop a high-performance liquid chromatography method, an Elite ODS C18 column (250 mm Χ 4.6 mm, 5μm at a column temperature of 30°C and flow rate of 1.0ml/min using acetonitrile (A and water (B as the mobile phase with a linear gradient and the peaks were monitored at 217 nm. Results: All calibration curves showed good linearity (r ≥ 0.9995 within test ranges. This method showed good repeatability for the quantification of these eleven components in S. chinensis with intra- and inter-day relative standard deviations less than 0.43% and 1.21%, respectively. In the recovery test, results of accuracy ranged from 99.51% to 101.31% with RSD values less than 2.68%, Conclusion: The validated method can be successfully applied to quantify the eleven investigated components in 22 samples of S. chinensis from different sources.

  13. Ionic liquids as stationary phases in gas chromatography: determination of chlorobenzenes in soils.

    Science.gov (United States)

    González Paredes, Rosa María; García Pinto, Carmelo; Pérez Pavón, José Luis; Moreno Cordero, Bernardo

    2014-06-01

    The present research focuses on the evaluation of different ionic liquid (IL) stationary phases in gas chromatography. The different IL columns were evaluated in terms of peak resolution (Rs) and peak symmetry for the separation of the chlorobenzenes. The determination of chlorobenzenes in soil samples by means of the optimal IL stationary phase (SLB-IL82) is proposed as an application. Soil pretreatment was based on a simplified quick, easy, cheap, effective, rugged, and safe extraction procedure and a large injection volume via a programed temperature vaporizer working in solvent vent mode. The retention time of the chlorobenzenes increased as the polarity of the IL column decreased. SLB-IL82 is the stationary phase that provides the best values as regards Rs and asymmetry factor. Soil sample blanks were spiked with the analytes before subjecting the sample to the extraction process. The existence of a matrix effect was checked and the analytical characteristics of the method were determined in a fortified garden soil sample. The method provided good linearity, good repeatability and reproducibility values, and the LODs were in the 0.1-4.7 μg/kg range. Two fortified soil samples were applied to validate the proposed methodology.

  14. Determination of the Thyreostats in Animal Feeding Stuffs Using Liquid Chromatography-Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Woźniak Barbara

    2014-10-01

    Full Text Available A rapid liquid chromatography tandem mass spectrometry method was developed and validated to detect and confirm five thyreostatic drugs: tapazole, thiouracil, methylthiouracil, propylthiouracil, and phenylthiouracil in animal feeding stuff samples. Thyreostats were extracted from feed with methanol, and then degreasing of the extract with petroleum ether was performed, followed by the derivatisation of the compounds with 3-iodobenzylbromide in basic medium (pH 8.0. The derivatives were extracted with diethyl ether and analysed by gradient elution on a Poroshell 120-EC C18 column with triple quadrupole MS detection with turbo spray source in positive ionisation mode. The method was validated in accordance with the Commission Decision 2002/657/EC. For validation level of 10 ļig kg-1, the recovery ranged from 82% to 97.5% for all examined compounds. The repeatability and reproducibility did not exceed the limit of 20% for all analytes. The linearity was good for all thyreostats in the whole range of tested concentrations, as proved by the correlation coefficients greater than 0.99. The decision limits (CCa ranged from 1.63 ļig kg-1 to 3.95 ļig kg-1, whereas the detection capabilities (CCß ranged from 2.74 ļig kg-1 to 6.73 ļig kg-1. The developed analysis is sensitive and robust, and therefore useful for quantification and confirmation of thyreostats in residue control programme.

  15. Stability study of simvastatin under hydrolytic conditions assessed by liquid chromatography.

    Science.gov (United States)

    Alvarez-Lueje, Alejandro; Valenzuela, Christian; Squella, Juan Arturo; Núñez-Vergara, Luis Joaquín

    2005-01-01

    In this work, a liquid chromatography stability-indicating method was developed and applied to study the hydrolytic behavior of simvastatin in different pH values and temperatures. The selected chromatographic conditions were a C18 column; acetonitrile-28 mM phosphate buffer solution, pH 4 (65 + 35) as the mobile phase; 251 degrees C column temperature; and flow rate 1 mL/min. The developed method exhibited an adequate repeatability and reproducibility (coefficient of variation 0.54 and 0.74%, respectively) and a recovery higher than 98%. Furthermore, the detection and quantification limits were 9.1 x 10(-7) and 2.8 x 10(-6) M, respectively. The degradation of simvastatin fitted to pseudo-first order kinetics. The degradation was pH dependent, being much higher at alkaline pH than at acid pH. Activation energy, kinetic rate constants (k) at different temperatures, the half life (t1/2) and the time for 10% degradation to occur (t90) values are also reported.

  16. Determination of total phthalates in edible oils by high-performance liquid chromatography coupled with photodiode array detection.

    Science.gov (United States)

    Xie, Qilong; Sun, Dekui; Han, Yangying; Jia, Litao; Hou, Bo; Liu, Shuhui; Li, Debao

    2016-03-01

    The previously reported procedure for the determination of the total phthalate in fatty food involved the extraction of phthalates using chloroform/methanol followed by the removal of the solvents before alkaline hydrolysis requiring 20 h and derivatization of phthalic acid. In this study, a phase-transfer catalyst (tetrabutylammonium chloride) was used in the liquid-liquid heterogeneous hydrolysis of phthalates in oil matrix shortening the reaction time to within 25 min. The resulting phthalic acid in the hydrolysate was extracted by a novel molecular complex based dispersive liquid-liquid microextraction method coupled with back-extraction before high-performance liquid chromatography coupled with photodiode array detection. Under the optimal experimental conditions, the linearity of the method was in the range of 0.5-12 nmol/g with the correlation coefficients (r) >0.997. The detection limit (S/N = 3) was 0.11 nmol/g. Intraday and interday repeatability values expressed as relative standard deviation were 3.9 and 7.1%, respectively. The recovery rates ranged from 82.4 to 99.0%. The developed method was successfully applied for the analysis of total phthalate in seven edible oils.

  17. Isolation and purification of six iridoid glycosides from gardenia jasminoides fruit by medium-pressure liquid chromatography combined with macroporous resin chromatography.

    Science.gov (United States)

    Wang, Yun; Liu, Hui; Shen, Lifeng; Yao, Lan; Ma, Yinlian; Yu, Dingrong; Chen, Jianhong; Li, Puling; Chen, Ying; Zhang, Cun

    2015-12-01

    Gardeniae fructus is one of the most frequently used herbs in traditional Chinese medicine. In the present study, a process for the enrichment of six iridoid glycosides from Gardeniae fructus was developed using medium-pressure liquid chromatography combined with macroporous resin and reversed-phase chromatography. The purities of different fractions from Gardeniae fructus were assessed using quantitative high-performance liquid chromatography. After fractionation using HPD-100 column chromatography, a 30% ethanol fraction was selected based on high-performance liquid chromatography and liquid chromatography with mass spectrometry qualitative analysis to separate and purify. Based on the orientation analysis results, six compounds-deacetyl asperulosidic acid methyl ester, gardenoside, ixoroside, scandoside methyl ester, genipin-1-O-β-d-gentiobioside, and geniposide-were successfully isolated and purified in three to four combined steps from Gardeniae fructus. The purities of these compounds were found by high-performance liquid chromatography analysis to be 97.9, 98.1, 95.5, 96.3, 97.1, and 98.7%, respectively. Moreover, their structures were elucidated by NMR spectroscopy and liquid chromatography with tandem mass spectrometry. The separation process was highly efficient, rapid, and accurate, making it a potential approach for the large-scale production of iridoids in the laboratory and providing several marker compounds for quality control. This procedure may be meaningful for the purification of other natural products used in traditional Chinese medicine.

  18. Screening and quantitative determination of twelve acidic and neutral pharmaceuticals in whole blood by liquid-liquid extraction and liquid chromatography-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Simonsen, Kirsten Wiese; Steentoft, Anni; Buck, Maike

    2010-01-01

    . The method was fully validated for salicylic acid, paracetamol, phenobarbital, carisoprodol, meprobamate, topiramate, etodolac, chlorzoxazone, furosemide, ibuprofen, warfarin, and salicylamide. The method also tentatively includes thiopental, theophylline, piroxicam, naproxen, diclophenac, and modafinil......We describe a multi-method for simultaneous identification and quantification of 12 acidic and neutral compounds in whole blood. The method involves a simple liquid-liquid extraction, and the identification and quantification are performed using liquid chromatography-tandem mass spectrometry...

  19. Analytical confirmation of lethal heroin overdose by the use of liquid chromatography methods

    Directory of Open Access Journals (Sweden)

    Đorđević Snežana

    2007-01-01

    Full Text Available Background/Aim. Heroin is diacetylated morphine. Its ability to induce euphoria has led to its frequent abuse, giving rise to psychological and physical dependence. It has a short half-life, of approximately 2−6 min. In the brain, heroin undergoes deacetylation to 6-monoacetylmorphine (6−MAM and morphine. Detection of 6-acetylmorphine in the urine is indicative of heroin use. The aim of this study was to compare sensitivity and reliability of two analytical methods, a multicolumn liquid chromatography system with UV scanning detector (HPLCUV and liquid chromatography-mass spectrometry detection (LC-MS in opiate determining in post mortem material. Methods. Post mortem samples (blood, urine and vitreous humor were analyzed by liquid chromatography with UV and MS detection. The samples were prepared by liquid-liquid extraction with mixture chloroform-isopropanol (9:1. Separation was performed on C8 column with mobile phase composed of 55% acetonitrile-glacial acetic acid (99:1 and 45% 20 mM ammonium acetate. Results. The analysis of blood samples, urine, and eye liquid by the use of multicolumn HPLC-UV method confirmed the presence of morphine in the samples of blood and urine, codeine only in urine, and 6-MAM in the samples of urine and eye liquid. Using LC-MS method morphine was confirmed in all of the samples, while codeine was confirmed in urine and in the sample of eye liquid. In the samples of eye liquid and urine 6-MAM was confirmed. Conclusion. For determination of opiates in post mortem material LC-MS technique is more sensitive and reliable as compared to multicolumn liquid chromatography.

  20. The Application of High Performance Liquid Chromatography in the Analysis of Trace Rare Earth

    Institute of Scientific and Technical Information of China (English)

    WANG; Xiu-feng; DING; You-qian

    2012-01-01

    <正>Rare earth elements are very important in the field of radioanalytical chemistry, for it must be separated and determined in the measurements of burn-up and fission yield. High performance liquid chromatography has become a main method in the separation of rare earth elements due to its obvious advantages, this is, high speed of analysis, high efficiency and easy automation. The ion exchange chromatography is the main means to separate rare earth elements, especially the cation exchange

  1. DETERMINATION OF ACRYLAMIDE IN FOOD BY GAS AND LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY

    OpenAIRE

    Michaela Vieriková; Miriam Vlčáková

    2010-01-01

     Acrylamide in food was determined by gas chromatography - mass spectrometry (GC-MS) after bromination of acrylamide and underivatized acrylamide was quantified by ultra performance liquid chromatography -mass spectrometry (UPLC-MS). Two different sample preparation methods were used and optimised. The GC-MS method was used for various food matrices like breads, potato crisps, potato crackers, french fries. The UPLC-MS method was used for analysis of coffee. The limit of detect...

  2. Surface Confined Ionic Liquid-A New Stationary Phase for the Separation of Ephedrines in High-performance Liquid Chromatography

    Institute of Scientific and Technical Information of China (English)

    Shu Juan LIU; Feng ZHOU; Xiao Hua XIAO; Liang ZHAO; Xia LIU; Sheng Xiang JIANG

    2004-01-01

    In this article, a new and effective stationary phase based on ionic liquid modified silica is first reported and used for the separation of ephedrines in high-performance liquid chromatography (HPLC). The separation results indicate the high efficiency and reproducibility of the stationary phase. The electrostatic interaction, ion-exchange interaction between the solutes and the stationary phase are considered to attribute the effective separation. Moreover, the free silanols on the surface of the silica are effectively masked by the immobilized ionic liquid, a result of which is to decrease the non-specific absorption.

  3. Determination of muscimol and ibotenic acid in Amanita mushrooms by high-performance liquid chromatography and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Tsujikawa, Kenji; Kuwayama, Kenji; Miyaguchi, Hajime; Kanamori, Tatsuyuki; Iwata, Yuko; Inoue, Hiroyuki; Yoshida, Takemi; Kishi, Tohru

    2007-06-01

    A reliable analytical method was developed for the quantification and identification of muscimol (MUS) and ibotenic acid (IBO), the toxic constituents of Amanita muscaria and Amanita pantherina. MUS and IBO were extracted from mushrooms by aqueous methanol and derivatized with dansyl chloride (DNS-Cl). After extraction with ethyl acetate and evaporation of the solvent, the residue was ethylated with 1.25 M hydrogen chloride in ethanol. The resulting derivatives were quantified by high-performance liquid chromatography with UV detection and identified by liquid chromatography electrospray ionization tandem mass spectrometry. Calibration curves were linear in the range of 25-2500 ppm for MUS and 40-2500 ppm for IBO, respectively. This method was successfully applied to identify and quantify MUS and IBO in Amanita mushrooms naturally grown and circulated in the drug market.

  4. On-line comprehensive two-dimensional normal-phase liquid chromatography×reversed-phase liquid chromatography for preparative isolation of toad venom.

    Science.gov (United States)

    Li, Jia-Fu; Fang, Hua; Yan, Xia; Chang, Fang-Rong; Wu, Zhen; Wu, Yun-Long; Qiu, Ying-Kun

    2016-07-22

    An on-line comprehensive preparative two-dimensional normal-phase liquid chromatography×reversed-phase liquid chromatography (2D NPLC×RPLC) system was constructed with a newly developed vacuum evaporation assisted adsorption (VEAA) interface, allowing fast removal of NPLC solvent in the vacuum condition and successfully solving the solvent incompatibility problem between NPLC and RPLC. The system achieved on-line solvent exchange within the two dimensions and its performance was illustrated by gram-scale isolation of crude extract from the venom of Bufo bufo gargarizans. Within separation time of ∼20h, 19 compounds were obtained with high purity in a single run. With the VEAA interface, the 2D system exhibited apparent advantages in separation efficiency and automation compared with conventional methods, indicating its promising application in the routine separation process for complicated natural products.

  5. Ultrasound-assisted ionic liquid-based homogeneous liquid-liquid microextraction high-performance liquid chromatography for determination of tanshinones in Salvia miltiorrhiza Bge. root.

    Science.gov (United States)

    Wang, Zhibing; Cao, Bocheng; Yu, Aimin; Zhang, Hanqi; Qiu, Fangping

    2015-02-01

    The ultrasound-assisted ionic liquid-based homogeneous liquid-liquid microextraction has been developed and applied to the extraction of four tanshinones, including dihydrotanshinone, tanshinone I, cryptotanshinone and tanshinone IIA in Salvia miltiorrhiza Bge. root. High performance liquid chromatography was applied to the separation and determination of the analytes. The ionic liquid was used as extraction solvent and target analytes were extracted with help of ultrasound. Then, ion-pairing agent was added into the sample solution, which resulted in the formation of water-insoluble ionic liquid in the solution. The phase separation was performed by centrifugation. The extraction, concentration and purification of target analytes were performed simultaneously. The experimental parameters, including type and volume of ionic liquid, sample amount, the size of sample particle, pH value of extraction medium, extraction temperature, extraction time, amount of ion-pairing agent and centrifuging time, were investigated and optimized. The calibration curves showed good linear relationship (r>0.9997). The limits of detection and quantification were in the range of 0.052-0.093 and 0.17-0.31 μg mL(-1), respectively. The recoveries were between 70.45% and 94.23% with relative standard deviations lower than 5.31%. The present method is free of volatile organic solvents, and represents lower expenditures of sample, extraction time and solvent, compared with UAE and HRE. There was no obvious difference in the extraction yields of active constitutions obtained by the three extraction methods.

  6. Fluorimetric assay for ornithine decarboxylase by high-performance liquid chromatography.

    Science.gov (United States)

    Haraguchi, K; Kai, M; Kohashi, K; Ohkura, Y

    1980-12-05

    A highly sensitive method for the assay of ornithine decarboxylase in sample solutions prepared from rat tissue homogenate is described which employs high-performance liquid chromatography with fluorescence detection. Putrescine formed from ornithine under the optimal conditions for the enzyme reaction is treated by Cellex P column chromatography for clean-up and converted into the fluorescamine derivative in the presence of cupric ion which inhibits the reaction of interfering amines with fluorescamine. The derivative is separated by reversed-phase chromatography on LiChrosorb RP-18 with linear gradient elution. The lower limit of detection for putrescine formed enzymatically is 5 pmol.

  7. High-performance liquid chromatography of oligoguanylates at high pH

    Science.gov (United States)

    Stribling, R.; Deamer, D. (Principal Investigator)

    1991-01-01

    Because of the stable self-structures formed by oligomers of guanosine, standard high-performance liquid chromatography techniques for oligonucleotide fractionation are not applicable. Previously, oligoguanylate separations have been carried out at pH 12 using RPC-5 as the packing material. While RPC-5 provides excellent separations, there are several limitations, including the lack of a commercially available source. This report describes a new anion-exchange high-performance liquid chromatography method using HEMA-IEC BIO Q, which successfully separates different forms of the guanosine monomer as well as longer oligoguanylates. The reproducibility and stability at high pH suggests a versatile role for this material.

  8. Rapid recognition of irradiated dry-cured ham by on-line coupling of reversed-phase liquid chromatography with gas chromatography and mass spectrometry.

    Science.gov (United States)

    Martínez, R M; Barba, C; Calvo, M M; Santa-María, G; Herraiz, M

    2011-06-01

    The use of on-line coupling of reversed-phase liquid chromatography and gas chromatography (RPLC-GC) with the through oven transfer adsorption desorption (TOTAD) interface and mass spectrometry (MS) was proposed for testing different types of commercial Spanish dry-cured ham for irradiation treatment at various doses (0, 1.5, 2, and 4 kGy). The qualitative analysis of radiation-specific compounds (e.g., n-pentadecane, 1-hexadecene, 1,7-hexadecadiene, n-heptadecane, 8-heptadecene, and 2-dodecylcyclobutanone) can be simultaneously established in a single run with samples that have or have not been irradiated. The overall analysis, which takes less than 100 min, includes a rapid extraction step using a small amount of dichloromethane-methanol (1:1, vol/vol) and anhydrous sodium sulfate, the subsequent fractionation of the sample in the first dimension of the system (RPLC), the transfer of the target fraction to the second dimension, the GC separation, and the MS detection. The calculated limits of detection in ham were lower than 22 ng/g. Repeatability studies provided relative standard deviation values of 0.8 to 13.5%.

  9. Dispersive liquid-liquid microextraction with little solvent consumption combined with gas chromatography-mass spectrometry for the pretreatment of organochlorine pesticides in aqueous samples.

    Science.gov (United States)

    Tsai, Wan-Chun; Huang, Shang-Da

    2009-07-03

    Dispersive liquid-liquid microextraction with little solvent consumption (DLLME-LSC), a novel dispersive liquid-liquid microextraction (DLLME) technique with few solvent requirements (13 microL of a binary mixture of disperser solvent and extraction solvent in the ratio of 6:4) and short extraction time (90 s), has been developed for extraction of organochlorine pesticides (OCPs) from water samples prior to gas chromatography/mass spectrometry analysis. In DLLME-LSC, much less volume of organic solvent is used as compared to DLLME. The new technique is less harmful to environment and yields a higher enrichment factor (1885-2648-fold in this study). Fine organic droplets were formed in the sample solution by manually shaking the test tube containing the mixture of sample solution and extraction solvent. The large surface area of the organic solvent droplets increases the rate of mass transfer from the water sample to the extractant and produces efficient extraction in a short period of time. DLLME-LSC shows good repeatability (RSD: 4.1-9.7% for reservoir water; 5.6-8.9% for river water) and high sensitivity (limits of detection: 0.8-2.5 ng/L for reservoir water; 0.4-1.3 ng/L for river water). The method can be used on various water samples (river water, tap water, sea water and reservoir water). It can be used for routine work for the investigation of OCPs.

  10. Chemical profiling and quantification of Gua-Lou-Gui-Zhi decoction by high performance liquid chromatography/quadrupole-time-of-flight mass spectrometry and ultra-performance liquid chromatography/triple quadrupole mass spectrometry.

    Science.gov (United States)

    Xu, Wen; Huang, Mingqing; Li, Huang; Chen, Xianwen; Zhang, Yuqin; Liu, Jie; Xu, Wei; Chu, Kedan; Chen, Lidian

    2015-04-01

    Gua-Lou-Gui-Zhi decoction (GLGZD) is a classical formula of traditional Chinese medicine, which has been commonly used to treat dysfunction after stroke, epilepsy and spinal cord injury. In this study, a systematic method was established for chemical profiling and quantification analysis of the major constituents in GLGZD. For qualitative analysis, a method of high performance liquid chromatography/quadrupole time-of-flight mass spectrometry (Q-TOF MS) was developed. 106 compounds, including monoterpene glycosides, galloyl glucoses, phenolic acids, flavonoids, gingerols and triterpene saponins were identified or tentatively presumed by comparison with reference standards or literature data. According to the qualitative results, a new quantitative analysis method of ultra-performance liquid chromatography/triple quadrupole mass spectrometry (QqQ-MS) was established. 24 representative compounds were simultaneously detected in 10 batches of GLGZD samples in 7.5 min. The calibration curves for all analytes showed good linearity (r>0.9959) within the test ranges. The LODs and the LOQs were less than 30.6 and 70.9 ng/mL, respectively. The RSDs of intra- and inter-day precision, repeatability and stability were below 3.64%, 4.85%, 4.84% and 3.87%, respectively. The overall recoveries ranged from 94.94% to 103.66%, with the RSDs within 5.12%. This study established a high sensitive and efficient method for the integrating quality control, including identification and quantification of Chinese medicinal preparation.

  11. Wide-scope screening and quantification of 50 pesticides in wine by liquid chromatography/quadrupole time-of-flight mass spectrometry combined with liquid chromatography/quadrupole linear ion trap mass spectrometry.

    Science.gov (United States)

    He, Zeying; Xu, Yaping; Wang, Lu; Peng, Yi; Luo, Ming; Cheng, Haiyan; Liu, Xiaowei

    2016-04-01

    In this paper, a wide scope screening method of pesticides in wine was established using liquid chromatography/quadrupole time-of-flight mass spectrometry (LC-QTOF MS) and liquid chromatography/quadrupole linear ion trap mass spectrometry (LC-QqLIT MS). Information dependent acquisition (IDA) experiments are used to obtain both MS and MS/MS information for LC-QTOF MS analysis. For LC-QqLIT MS analysis, MS/MS spectra of target pesticides were simultaneously acquired using Enhanced Product Ion (EPI) mode at very low concentrations to increase the confidence in analytical results of multiple reaction monitoring (MRM) by library searching. Method validation was carried out using 50 pesticides commonly used in vineyards. The LOQs, linearity, repeatability were determined and good enough for quantification. The screening and quantification results obtained using LC-QTOF MS and LC-QqLIT MS were compared. Contaminants were screened against libraries containing over 2800 compounds based on accurate mass, isotopic patterns, and MS/MS spectra searching to extend the scope of this methodology to non-target screening.

  12. Comprehensive two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography for analysis of toad skin.

    Science.gov (United States)

    Li, Jia-Fu; Yan, Xia; Wu, Yun-Long; Fang, Mei-Juan; Wu, Zhen; Qiu, Ying-Kun

    2017-04-15

    An analytical two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography (2D NPLC × RPLC) system was constructed with a newly developed thermal evaporation assisted adsorption (TEAA) interface. This novel TEAA interface with heating temperature above solvent boiling point allowed fast removal of organic NPLC solvent and successfully solved the solvent incompatibility problem between NPLC and RPLC. The system achieved rapid on-line solvent exchange between the two dimensions within a short modulation time of 190 s and was applied in the analysis of an extract from the skin of Bufo bufo gargarizans. This is the first time to realize the on-line comprehensive analysis of a moderate polar natural product by coupling NPLC with reversed phase ultra-high performance liquid chromatography (UHPLC). To be highlighted, with the TEAA interface, the 2D NPLC × RPLC system provided excellent resolution and orthogonality (75.2%), when compared with that of 2D RPLC × RPLC.

  13. Preparation and chromatographic evaluation of a newly designed steviol glycoside modified-silica stationary phase in hydrophilic interaction liquid chromatography and reversed phase liquid chromatography.

    Science.gov (United States)

    Liang, Tu; Fu, Qing; Shen, Aijin; Wang, Hui; Jin, Yu; Xin, Huaxia; Ke, Yanxiong; Guo, Zhimou; Liang, Xinmiao

    2015-04-03

    A diterpene glycoside compound, rebaudioside A (commonly abbreviated as RA), was immobilized onto porous silica surface through "thiol-ene" click chemistry strategy. The successful immobilization of the RA on the silica support was confirmed by FT-IR and elemental analysis. Chromatographic characteristics of the new stationary phase, named Click TE-RA, were evaluated by a set of diverse analytes such as carbohydrates, nucleosides, and organic acids in hydrophilic interaction liquid chromatography (HILIC) mode. The effects of water content, buffer pH and concentration were investigated and a typical HILIC retention feature of Click TE-RA was observed at high organic modifier content. The Click TE-RA stationary phase was further studied by a series of glycoside compounds. Tunable retention mechanisms from hydrophilic to hydrophobic interactions were observed. Separation of very polar compounds including oligosaccharides, nucleic acid bases and nucleosides using Click TE-RA in HILIC mode was successfully accomplished. In addition, separation of saponins both in HILIC and reversed-phase liquid chromatography (RPLC) modes was performed, demonstrating the presence of orthogonality between two different modes on Click TE-RA column. The multiple interactions induced by polar sugar group and hydrophobic aglycone group allowed this Click TE-RA to serve as a multi-mode stationary phase in two-dimensional liquid chromatography.

  14. Determination of five antiarrhythmic drugs in human plasma by dispersive liquid-liquid microextraction and high-performance liquid chromatography.

    Science.gov (United States)

    Jouyban, Abolghasem; Sorouraddin, Mohammad Hossein; Farajzadeh, Mir Ali; Somi, Mohammad Hossein; Fazeli-Bakhtiyari, Rana

    2015-03-01

    A fast and sensitive high-performance liquid chromatography (HPLC) method with ultraviolet (UV) detection was developed and validated for the simultaneous quantitation of five antiarrhythmic drugs (metoprolol, propranolol, carvedilol, diltiazem, and verapamil) in human plasma samples. It involves dispersive liquid-liquid microextraction (DLLME) of the desired drugs from 660 µL plasma and separation using isocratic elution with UV detection at 200 nm. The complete separation of all analytes was achieved within 7 min. Acetonitrile (as disperser solvent) resulting from the protein precipitation procedure was mixed with 100 µL dichloromethane (as an extraction solvent) and rapidly injected into 5 mL aqueous solution (pH 11.5) containing 1% (w/v), NaCl. After centrifugation, the sedimented phase containing enriched analytes was collected and evaporated to dryness. The residue was re-dissolved in 50 µL de-ionized water (acidified to pH 3) and injected into the HPLC system for analysis. Under the optimal conditions, the enrichment factors and extraction recoveries ranged between 4.4-10.8 and 33-82%, respectively. The suggested method was linear (r(2) ≥0.997) over a dynamic range of 0.02-0.80 µg mL(-1) in plasma. The intra- and inter-days relative standard deviation (RSD%) and relative error (RE%) values of the method were below 20%, which shows good precision and accuracy. Finally, this method was applied to the analysis of real plasma samples obtained from the patients treated with these drugs.

  15. Analysis of drugs of abuse in human plasma by dispersive liquid-liquid microextraction and high-performance liquid chromatography.

    Science.gov (United States)

    Fernández, P; Regenjo, M; Bermejo, A M; Fernández, A M; Lorenzo, R A; Carro, A M

    2015-04-01

    Opioids and cocaine are widely used at present, both for recreational purposes and as drugs of abuse. This raises the need to develop new analytical methods specifically designed for the simultaneous detection of several drugs of abuse in biological samples. In this work, dispersive liquid-liquid microextraction (DLLME) was assessed as a new sample treatment for the simultaneous extraction of morphine (MOR), 6-acetylmorphine (6AM), cocaine (COC), benzoylecgonine (BZE) and methadone (MET) from human plasma. Preliminary assays were done before developing an experimental design based on a Uniform Network Doehlert which allowed the optimum extraction conditions to be identified, namely: a volume of extractant solvent (chloroform) and dispersant solvent (acetonitrile) of 220 µl and 3.2 ml, respectively; 0.2 g of NaCl as a salting-out additive; pH 10.6 and ultrasound stirring for 3.5 min. The resulting extracts were analyzed by high-performance liquid chromatography with photodiode array detection (HPLC-PDA), using an XBridge® RP18 column (250 × 4.6 mm i.d., 5 µm particle size). Calibration graphs were linear over the concentration range 0.1-10 µg ml⁻¹, and detection limits ranged from 13.9 to 28.5 ng ml⁻¹. Precision calculated at three different concentration levels in plasma was included in the range 0.1-6.8% RSD. Recoveries of the five drugs were all higher than 84% on average. Finally the proposed method was successfully applied to 22 plasma samples from heroin, cocaine and/or methadone users, and the most frequently detected drug was benzoylecgonine, followed by methadone, cocaine and morphine.

  16. Microwave-assisted ionic liquid homogeneous liquid-liquid microextraction coupled with high performance liquid chromatography for the determination of anthraquinones in Rheum palmatum L.

    Science.gov (United States)

    Wang, Zhibing; Hu, Jianxue; Du, Hongxia; He, Shuang; Li, Qing; Zhang, Hanqi

    2016-06-01

    The microwave-assisted ionic liquid homogeneous liquid-liquid microextraction (MA-IL-HLLME) coupled with high performance liquid chromatography with diode array detection (HPLC-DAD) was developed for the determination of anthraquinones, including aloe-emodin, emodin, chrysophanol and physcion in root of Rheum palmatum L. Several experimental parameters influencing the extraction efficiency, including amount of sample, type and volume of ionic liquid, volume and pH value of extraction medium, microwave power and extraction time, concentration of NH4PF6 as well as centrifugal condition were optimized. When 140μL of ionic liquid ([C8MIM][BF4]) was used as an extraction solvent, target analytes can be extracted from sample matrix in one minute with the help of microwave irradiation. The MA-IL-HLLME is simple and quick. The calibration curves exhibited good linear relationship (r>0.9984). The limits of detection and quantification were in the range of 0.015-0.026 and 0.051-0.088μgmL(-1), respectively. The spiked recovery for each analyte was in the range of 81.13-93.07% with relative standard deviations lower than 6.89%. The present method is free of volatile organic solvents, and represents lower expenditures of sample, extraction time and solvent, compared with ultrasonic and heat reflux extraction. The results indicated that the present method can be successfully applied to the determination of anthraquinones in medicinal plant.

  17. [Determination of five triazine herbicides in infant milk powder by high performance liquid chromatography coupled with ionic liquid-based homogeneous liquid-liquid microextraction].

    Science.gov (United States)

    Zhang, Liyuan; Yao, Di; Li, Na; Zhang, Hanqi; Yu, Aimin

    2015-07-01

    A high performance liquid chromatography coupled with homogeneous liquid-liquid microextraction was developed for the determination of five triazine herbicides in infant milk powders. The ionic liquid was used as microextraction solvent. The separation of the herbicides was performed on an Eclipse XDB-C18 column using acetonitrile and water as mobile phases in gradient mode. The effects of homogeneous liquid-liquid extraction conditions on the experimental results were investigated in detail. Under the optimized experimental conditions, the calibration curves for determining the analytes were linear and the correlation coefficients were ≥ 0.9992. The limits of detection for cyanazine, desmetryn, terbumeton, terbuthylazine and dimethametryn were 12.1, 13.8, 11.8, 14.6 and 13.7 μg/kg, respectively. The recoveries of the analytes spiked in four infant milk powders ranged from 92.2% to 103.2% and the relative standard deviations were lower than 6%. This method is sensitive, simple, and suitable for the determination of triazine herbicides in milk powder samples.

  18. Identification of Explosives from Porous Materials: Applications Using Reverse Phase High Performance Liquid Chromatography and Gas Chromatography

    Energy Technology Data Exchange (ETDEWEB)

    C.J. Miller; G. Elias; N.C. Schmitt; C. Rae

    2010-06-01

    High performance liquid chromatography and gas chromatography techniques are well documented and widely used for the detection of trace explosives from organic solvents. These techniques were modified to specifically identify and quantify explosives extracted from various materials taken from people who had recently handled explosives. Documented techniques were modified to specifically detect and quantify RDX, TNT, and PETN from denim, colored flannel, vinyl, and canvas extracted in methanol using no sample cleanup prior to analysis. The methanol extracts were injected directly into several different column types and analyzed by HPLC-UV and/or GC-ECD. This paper describes general screening methods that were used to determine the presence of explosives in unknown samples and techniques that have been optimized for quantification of each explosive from the substrate extracts.

  19. High-performance liquid chromatography with fluorescence detection for the rapid analysis of pheophytins and pyropheophytins in virgin olive oil.

    Science.gov (United States)

    Li, Xueqi; Woodman, Michael; Wang, Selina C

    2015-08-01

    Pheophytins and pyropheophytin are degradation products of chlorophyll pigments, and their ratios can be used as a sensitive indicator of stress during the manufacturing and storage of olive oil. They increase over time depending on the storage condition and if the oil is exposed to heat treatments during the refining process. The traditional analysis method includes solvent- and time-consuming steps of solid-phase extraction followed by analysis by high-performance liquid chromatography with ultraviolet detection. We developed an improved dilute/fluorescence method where multi-step sample preparation was replaced by a simple isopropanol dilution before the high-performance liquid chromatography injection. A quaternary solvent gradient method was used to include a fourth strong solvent wash on a quaternary gradient pump, which avoided the need to premix any solvents and greatly reduced the oil residues on the column from previous analysis. This new method not only reduces analysis cost and time but shows reliability, repeatability, and improved sensitivity, especially important for low-level samples.

  20. Separation of polyethylene glycols and maleimide-terminated polyethylene glycols by reversed-phase liquid chromatography under critical conditions.

    Science.gov (United States)

    Wei, Yanzhen; Zhuo, Renxi; Jiang, Xulin

    2016-11-01

    The separation of polyethylene glycols and maleimide-substituted polyethylene glycol derivatives based on the number of maleimide end-groups under critical liquid chromatography conditions has been investigated on a reversed-phase column. The critical solvent compositions for nonfunctional polyethylene glycols and bifunctional maleimide-substituted polyethylene glycols were determined to be identical at about 40% acetonitrile in water on a reversed-phase octadecyl carbon chain-bonded silica column using mixtures of acetonitrile and water of varying composition as the mobile phase at 25°C. The maleimide-functionalized polyethylene glycols were successfully separated according to maleimide functionality (with zero, one, two, or three maleimide end-groups, respectively) under the critical isocratic elution conditions without obvious effect of molar mass. The separation was mainly due to the hydrophobic interaction between the maleimide end-groups and the column packing. Off-line matrix-assisted laser desorption/ionization time of flight mass spectrometry was used to identify the repeating units and, especially, the end-groups of the maleimide-substituted polyethylene glycols. Liquid chromatography analysis at critical conditions could provide useful information to optimize the synthesis of functional polyethylene glycols. To our knowledge, this is the first report of the baseline separation of maleimide-functionalized polyethylene glycols based on the functionality independent of the molar mass without derivatization by isocratic elution.

  1. Application of Holistic Liquid Chromatography-High Resolution Mass Spectrometry Based Urinary Metabolomics for Prostate Cancer Detection and Biomarker Discovery.

    Directory of Open Access Journals (Sweden)

    Tong Zhang

    Full Text Available Human exhibit wide variations in their metabolic profiles because of differences in genetic factors, diet and lifestyle. Therefore in order to detect metabolic differences between individuals robust analytical methods are required. A protocol was produced based on the use of Liquid Chromatography- High Resolution Mass Spectrometry (LC-HRMS in combination with orthogonal Hydrophilic Interaction (HILIC and Reversed Phase (RP liquid chromatography methods for the analysis of the urinary metabolome, which was then evaluated as a diagnostic tool for prostate cancer (a common but highly heterogeneous condition. The LC-HRMS method was found to be robust and exhibited excellent repeatability for retention times (0.9. In addition, using the receiver operator characteristics (ROC test, the area under curve (AUC for the combination of the four best characterised biomarker compounds was 0.896. The four biomarker compounds were also found to differ significantly (P<0.05 between an independent patient cohort and controls. This is the first time such a rigorous test has been applied to this type of model. If validated, the established protocol provides a robust approach with a potentially wide application to metabolite profiling of human biofluids in health and disease.

  2. Analysis of nitroguanidine in Aqueous Solutions by HPLC (High Performance Liquid Chromatography) with electrochemical Detection and Voltammetry

    Science.gov (United States)

    1987-04-01

    The nitroguanidine was analyzed by high performance liquid chromatography (HPLC) with electrochemical detection at a hanging miercury drop electrode...previously reported on the application of solid sorbent collection techniques to the analysis of several explosives in water by high performance liquid chromatography (HPLC

  3. Application in pesticide analysis: Liquid chromatography - A review of the state of science for biomarker discovery and identification

    Science.gov (United States)

    Book Chapter 18, titled Application in pesticide analysis: Liquid chromatography - A review of the state of science for biomarker discovery and identification, will be published in the book titled High Performance Liquid Chromatography in Pesticide Residue Analysis (Part of the C...

  4. Identifying Ca2+-Binding Sites in Proteins by Liquid Chromatography-Mass Spectrometry Using Ca2+-Directed Dissociations

    NARCIS (Netherlands)

    Jamalian, Azadeh; Sneekes, Evert-Jan; Wienk, Hans; Dekker, Lennard J. M.; Ruttink, Paul J. A.; Ursem, Mario; Luider, Theo M.; Burgers, Peter C.

    2014-01-01

    Here we describe a new method to identify calcium-binding sites in proteins using high-resolution liquid chromatography-mass spectrometry in concert with calcium-directed collision-induced dissociations. Our method does not require any modifications to the liquid chromatography-mass spectrometry app

  5. DETERMINATION OF CARBENDAZIM IN WATER BY HIGH-PERFORMANCE IMMUNOAFFINITY CHROMATOGRAPHY ON-LINE WITH HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY WITH DIODE-ARRAY OR MASS SPECTROMETRIC DETECTION

    Science.gov (United States)

    An automated method for the determination of carbendazim in water that combines high-performance immunoaffinity chromatography (HPIAC), high-performance liquid chromatography (HPLC) in the reversed-phase mode, and detection by either UV-Vis diode array detector (DAD) spectroscopy...

  6. Comparison of gas chromatography/isotope ratio mass spectrometry and liquid chromatography/isotope ratio mass spectrometry for carbon stable-isotope analysis of carbohydrates

    NARCIS (Netherlands)

    Moerdijk-Poortvliet, T.C.W.; Schierbeek, H.; Houtekamer, M.; van Engeland, T.; Derrien, D.; Stal, L.J.; Boschker, H.T.S.

    2015-01-01

    We compared gas chromatography/isotope ratio mass spectrometry (GC/IRMS) and liquid chromatography/isotope ratio mass spectrometry (LC/IRMS) for the measurement of d13C values in carbohydrates. Contrary to GC/IRMS, no derivatisation is needed for LC/IRMS analysis of carbohydrates. Hence, although

  7. The analysis of aqueous mixtures using liquid chromatography-electrospray mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Steven [Iowa State Univ., Ames, IA (United States)

    1999-02-12

    The focus of this dissertation is the use of chromatographic methods coupled with electrospray mass spectrometry (ES-MS) for the determination of both organic and inorganic compounds in aqueous solutions. The combination of liquid chromatography (LC) methods and ES-MS offers one of the foremost methods for determining compounds in complex aqueous solutions. In this work, LC-ES-MS methods are devised using ion exclusion chromatography, reversed phase chromatography, and ion exchange chromatography, as well as capillary electrophoresis (CE). For an aqueous sample, these LC-ES-MS and CE-ES-MS techniques require no sample preparation or analyte derivatization, which makes it possible to observe a wide variety of analytes as they exist in solution. The majority of this work focuses on the use of LC-ES-MS for the determination of unknown products and intermediates formed during electrochemical incineration (ECI), an experimental waste remediation process. This report contains a general introduction to the project and the general conclusions. Four chapters have been removed for separate processing. Titles are: Chapter 2: Determination of small carboxylic acids by ion exclusion chromatography with electrospray mass spectrometry; Chapter 3: Electrochemical incineration of benzoquinone in aqueous media using a quaternary metal oxide electrode in the absence of a soluble supporting electrolyte; Chapter 4: The determination of electrochemical incineration products of 4-chlorophenol by liquid chromatography-electrospray mass spectrometry; and Chapter 5: Determination of small carboxylic acids by capillary electrophoresis with electrospray mass spectrometry.

  8. Liquid chromatography and supercritical fluid chromatography as alternative techniques to gas chromatography for the rapid screening of anabolic agents in urine.

    Science.gov (United States)

    Desfontaine, Vincent; Nováková, Lucie; Ponzetto, Federico; Nicoli, Raul; Saugy, Martial; Veuthey, Jean-Luc; Guillarme, Davy

    2016-06-17

    This work describes the development of two methods involving supported liquid extraction (SLE) sample treatment followed by ultra-high performance liquid chromatography or ultra-high performance supercritical fluid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS and UHPSFC-MS/MS) for the screening of 43 anabolic agents in human urine. After evaluating different stationary phases, a polar-embedded C18 and a diol columns were selected for UHPLC-MS/MS and UHPSFC-MS/MS, respectively. Sample preparation, mobile phases and MS conditions were also finely tuned to achieve highest selectivity, chromatographic resolution and sensitivity. Then, the performance of these two methods was compared to the reference routine procedure for steroid analyses in anti-doping laboratories, which combines liquid-liquid extraction (LLE) followed by gas chromatography coupled to tandem mass spectrometry (GC-MS/MS). For this purpose, urine samples spiked with the compounds of interest at five different concentrations were analyzed using the three analytical platforms. The retention and selectivity of the three techniques were very different, ensuring a good complementarity. However, the two new methods displayed numerous advantages. The overall procedure was much faster thanks to high throughput SLE sample treatment using 48-well plates and faster chromatographic analysis. Moreover, the highest sensitivity was attained using UHPLC-MS/MS with 98% of the doping agents detected at the lowest concentration level (0.1ng/mL), against 76% for UHPSFC-MS/MS and only 14% for GC-MS/MS. Finally, the weakest matrix effects were obtained with UHPSFC-MS/MS with 76% of the analytes displaying relative matrix effect between -20 and 20%, while the GC-MS/MS reference method displayed very strong matrix effects (over 100%) for all of the anabolic agents.

  9. DETERMINATION OF ENZYME-ACTIVITY BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

    NARCIS (Netherlands)

    WELLING, GW; SCHEFFER, AJ; WELLINGWESTER, S

    1994-01-01

    The application of high-performance liquid chromatography (HPLC) in the study of enzymatic reactions is reviewed. The rationale for using HPLC is given and whether the components of the reaction mixture should be derivatized prior to or after HPLC. An alphabetical list of enzymes assayed by HPLC is

  10. Determination of daminozide in apples and apple leaves by liquid chromatography-mass spectrometry

    NARCIS (Netherlands)

    Mol, H.G.J.; Dam, R.C.J. van; Vreeken, R.J.; Steijger, O.M.

    1999-01-01

    A straightforward and efficient method was developed for the determination of intact daminozide in apples and apple leaves. After extraction with methanol and a clean-up step using a graphitized carbon cartridge, the extract was analysed by ion-trap liquid chromatography-tandem mass spectrometry (LC

  11. High-performance liquid chromatography of rat and mouse islet polypeptides

    DEFF Research Database (Denmark)

    Linde, S; Hansen, B; Welinder, B S

    1990-01-01

    After preparative high-performance liquid chromatography of mouse islet culture medium, concentrated on disposable C18 cartridges (Sep-Pak), an unexpected insulin immunoreactive peak eluting earlier than mouse insulin I and II was detected. Molecular mass determination by mass spectrometry...

  12. Going Beyond, Going Further: An Inexpensive Experiment for the Introduction of High Performance Liquid Chromatography.

    Science.gov (United States)

    Bidlingmeyer, Brian A.; Warren, F. Vincent, Jr.

    1984-01-01

    Background information, materials needed, laboratory procedures, and typical results are provided for five high performance liquid chromatography experiments (three isocratic and two step gradient separations). Suggestions for further experimentation are also provided, including quantitative determinations and separation of charged solutes. (JN)

  13. Quantitative separation of tetralin hydroperoxide from its decomposition products by high performance liquid chromatography

    Science.gov (United States)

    Worstell, J. H.; Daniel, S. R.

    1981-01-01

    A method for the separation and analysis of tetralin hydroperoxide and its decomposition products by high pressure liquid chromatography has been developed. Elution with a single, mixed solvent from a micron-Porasil column was employed. Constant response factors (internal standard method) over large concentration ranges and reproducible retention parameters are reported.

  14. Extraction and Purification of Glucoraphanin by Preparative High-Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    Lee, Iris; Boyce, Mary C.

    2011-01-01

    A student activity that focuses on the isolation of glucoraphanin from broccoli using preparative high-performance liquid chromatography (HPLC) is presented here. Glucoraphanin is a glucosinolate, whose byproducts are known to possess anticancer properties. It is present naturally at high levels in broccoli and other "Brassica" vegetables. This…

  15. High-Performance Liquid Chromatography in the Undergraduate Chemical Engineering Laboratory

    Science.gov (United States)

    Frey, Douglas D.; Guo, Hui; Karnik, Nikhila

    2013-01-01

    This article describes the assembly of a simple, low-cost, high-performance liquid chromatography (HPLC) system and its use in the undergraduate chemical engineering laboratory course to perform simple experiments. By interpreting the results from these experiments students are able to gain significant experience in the general method of…

  16. DETERMINATION OF CHLOROPHENOLS, NITROPHENOLS, AND METHYLPHENOLS IN GROUND-WATER SAMPLES USING HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

    Science.gov (United States)

    A high performance liquid chromatography (HPLC) method was developed to quantitatively determine phenolic compounds and their isomers in aqueous samples. The HPLC method can analyze a mixture of 15 contaminants in the same analytical run with an analysis time of 25 minutes. The...

  17. Determination of low molecular weight thiols using monobromobimane fluorescent labeling and high-performance liquid chromatography

    Science.gov (United States)

    Fahey, Robert C.; Newton, Gerald L.

    1988-01-01

    Methods are described for the preparation and high-performance liquid chromatography (HPLC) analysis of monobromobimane derivatives of low molecular weight thiols in extracts of biological samples. Typical problems encountered in the development and application of these methods are discussed. Analysis of mung bean extract is used as an example.

  18. High Performance Liquid Chromatography of Some Analgesic Compounds: An Instrumental Analysis Experiment.

    Science.gov (United States)

    Haddad, Paul; And Others

    1983-01-01

    Background information, procedures, and results are provided for an experiment demonstrating techniques of solvent selection, gradient elution, pH control, and ion-pairing in the analysis of an analgesic mixture using reversed-phase liquid chromatography on an octadecylsilane column. Although developed using sophisticated/expensive equipment, less…

  19. Sugar Determination in Foods with a Radially Compressed High Performance Liquid Chromatography Column.

    Science.gov (United States)

    Ondrus, Martin G.; And Others

    1983-01-01

    Advocates use of Waters Associates Radial Compression Separation System for high performance liquid chromatography. Discusses instrumentation and reagents, outlining procedure for analyzing various foods and discussing typical student data. Points out potential problems due to impurities and pump seal life. Suggests use of ribose as internal…

  20. Simultaneous quantitative analysis of metabolites using ion-pair liquid chromatography-electrospray ionization mass spectrometry

    NARCIS (Netherlands)

    Coulier, L.; Bas, R.; Jespersen, S.; Verheij, E.; Werf, M.J. van der; Hankemeier, T.

    2006-01-01

    We have developed an analytical method, consisting of ion-pair liquid chromatography coupled to electrospray ionization mass spectrometry (IP-LC-ESI-MS), for the simultaneous quantitative analysis of several key classes of polar metabolites, like nucleotides, coenzyme A esters, sugar nucleotides, an

  1. Experimental hydrophobicity parameters of perfluorinated alkylated substances from reversed-phase high performance liquid chromatography

    NARCIS (Netherlands)

    de Voogt, P.; Zurano, L.; Serné, P.; Haftka, J.J.H.

    2012-01-01

    Capacity factors of perfluorinated alkylated substances were obtained from isocratic reversed-phase high-performance liquid chromatography-mass spectrometry experiments at different organic modifier strengths of the mobile phase. The resulting capacity factor v. modifier strengths plots were extrapo

  2. Comparison of high performance liquid chromatography and enzymatic analysis of soluble carbohydrates in loblolly pine

    Science.gov (United States)

    Patricia L. Faulkner; Michele M. Schoeneberger; Kim H. Ludovici

    1993-01-01

    Foliar tissue was collected from a field study designed to test impacts of atmospheric pollutants on loblolIy pine (Pinus taeda L.) seedlings. Standard enzymatic (ENZ) and high performance liquid chromatography (HPLC) methods were used to analyze the tissue for soluble sugars. A comparison of the methods revealed no significant diffennces in accuracy...

  3. Analysis of Currently Available Analgesic Tablets by Modern Liquid Chromatography: An Undergraduate Laboratory Introduction to HPLC.

    Science.gov (United States)

    Kagel, R. A.; Farwell, S. O.

    1983-01-01

    Background information, procedures, and results, are provided for an undergraduate experiment in which analgesic tablets are analyzed using liquid chromatography. The experiment, an improved, modified version of the Waters Associates Inc. experiment, is simple to prepare, requiring little glassware and minimal sample manipulation by students. (JN)

  4. Sensitive, Preclinical Detection of Prions in Brain by nanospray liquid chromatography/tandem mass spectrometry

    Science.gov (United States)

    More sensitive detection of prions in brain is important because it would allow early detection of disease in young animals and assure a safer food supply. We quantitated the amount of proteinase K-resistant prion protein (PrP 27-30) by use of nano-scale liquid chromatography coupled to a tandem ma...

  5. Sorption of catechins under conditions of reverse-phase high-efficiency liquid chromatography

    Science.gov (United States)

    Shafigulin, R. V.; Egorova, K. V.; Bulanova, A. V.

    2010-08-01

    The physico-chemical principles of catechin sorption from various polar solvents onto silica gel modified with octadecyl groups were studied. Thermodynamic characteristics of the sorption were calculated, and the applicability of different models of retention was demonstrated for catechins under the conditions of reverse-phase high-efficiency liquid chromatography.

  6. The role of liquid chromatography-tandem mass spectrometry in the clinical laboratory

    NARCIS (Netherlands)

    van den Ouweland, Johannes M. W.; Kema, Ido P.

    2012-01-01

    Liquid chromatography coupled to mass spectrometry (LC-MS/MS) is increasingly used as a routine methodology in clinical laboratories for the analysis of low molecular weight molecules. The high specificity in combination with high sensitivity and multi-analyte potential makes it an attractive comple

  7. Simulated Moving Bed Chromatography: Separation and Recovery of Sugars and Ionic Liquid from Biomass Hydrolysates

    Science.gov (United States)

    Caes, Benjamin R.; Van Oosbree, Thomas R.; Lu, Fachuang; Ralph, John; Maravelias, Christos T.

    2015-01-01

    Simulated moving bed chromatography, a continuous separation method, enables the nearly quantitative recovery of sugar products and ionic liquid solvent from chemical hydrolysates of biomass. The ensuing sugars support microbial growth, and the residual lignin from the process is intact. PMID:23939991

  8. An Advanced, Interactive, High-Performance Liquid Chromatography Simulator and Instructor Resources

    Science.gov (United States)

    Boswell, Paul G.; Stoll, Dwight R.; Carr, Peter W.; Nagel, Megan L.; Vitha, Mark F.; Mabbott, Gary A.

    2013-01-01

    High-performance liquid chromatography (HPLC) simulation software has long been recognized as an effective educational tool, yet many of the existing HPLC simulators are either too expensive, outdated, or lack many important features necessary to make them widely useful for educational purposes. Here, a free, open-source HPLC simulator is…

  9. Characterization of Pentachlorophenol in Soil by Liquid Chromatography-Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    JIN Mi-cong; WANG Biao

    2004-01-01

    A simple, accurate and sensitive method for characterization of pentachlorophenol in soil was presented. The method included Soxhlet extraction using extracting agent of methanol/water/triethylamine (80∶20∶2), decontamination using solid-phase extraction (SPE) column and characterization by liquid chromatography-mass spectrometry (LCMS). The developed analytical method was successfully used to the determination of pentachlorophenol in soil samples.

  10. High-Performance Liquid Chromatography in the Undergraduate Chemical Engineering Laboratory

    Science.gov (United States)

    Frey, Douglas D.; Guo, Hui; Karnik, Nikhila

    2013-01-01

    This article describes the assembly of a simple, low-cost, high-performance liquid chromatography (HPLC) system and its use in the undergraduate chemical engineering laboratory course to perform simple experiments. By interpreting the results from these experiments students are able to gain significant experience in the general method of…

  11. An on-line high performance liquid chromatography-crocin bleaching assay for detection of antioxidants

    NARCIS (Netherlands)

    Bountagkidou, O.; Klift, van der E.J.C.; Tsimidou, M.Z.; Ordoudi, S.A.; Beek, van T.A.

    2012-01-01

    An on-line HPLC (high performance liquid chromatography) method for the rapid screening of individual antioxidants in mixtures was developed using crocin as a substrate (i.e. oxidation probe) and 2,2'-azobis(2-amidinopropane dihydrochloride (AAPH)) in phosphate buffer (pH 7.5) as a radical generator

  12. Determination of Peroxide-Based Explosives Using Liquid Chromatography with On-Line Infrared Detection

    NARCIS (Netherlands)

    Schulte-Ladbeck, Rasmus; Edelmann, Andrea; Quintas, Guillermo; Lendl, Bernhard; Karst, U.

    2006-01-01

    A nondestructive analytical method for peroxide-based explosives determination in solid samples is described. Reversed-phase high-performance liquid chromatography in combination with on-line Fourier transform infrared (FT-IR) detection is used for the analysis of triacetonetriperoxide (TATP) and

  13. Isotope Fractionation in Methane Reactions Studied by Gas Chromatography and Liquid Scintillation

    DEFF Research Database (Denmark)

    Andersen, Bertel Lohmann; Bidoglio, G.; Leip, A.

    1997-01-01

    Determination of C-14-marked methane by gas chromatography and liquid scintillation counting is shown to be useful in studies of isotope effects. Data on the specific activity is used to separate the contributions of (CH4)-C-14, and (CH4)-C-12 to the gas-chromatographic peak area. As an application...

  14. Simultaneous determination of seven flavonoids in Epimedium by liquid chromatography-tandem mass spectrometry method

    Institute of Scientific and Technical Information of China (English)

    Cai Sheng Wu; Bao Lin Guo; Yu Xin Sheng; Jin Lan Zhang

    2008-01-01

    In this paper, a sensitive and specific liquid chromatography-electrospray ionisation-mass spectrometry (LC-ESI-MS) method has been developed and validated for the identification and determination of seven flavonoids, namely epimedin A, epimedin B, epimedin C, icariin, sagittatoside B, 2"-0-rhamnosyl icariside II, and baohuoside I in Epimedium from different sources.

  15. The Separation and Identification of Straight Chain Hydrocarbons: An Experiment Using Gas-Liquid Chromatography.

    Science.gov (United States)

    Benson, G. A.

    1982-01-01

    An experiment using gas-liquid chromatography is discussed, introducing the student to concept of dead volume and its measurement, idea and use of an internal reference compound, and to linear relationship existing between measurements of a separation on two different stationary phases. (Author/SK)

  16. Characterization of typical chemical background interferences in atmospheric pressure ionization liquid chromatography-mass spectrometry

    NARCIS (Netherlands)

    Guo, Xinghua; Bruins, Andries P.; Covey, Thomas R.

    2006-01-01

    The structures and origins of typical chemical background noise ions in positive atmospheric pressure ionization liquid chromatography/mass spectrometry (API LC/MS) are investigated and summarized in this study. This was done by classifying chemical background ions using precursor and product ion sc

  17. Alternative sample-introduction technique to avoid breakthrough in gradient-elution liquid chromatography of polymers

    NARCIS (Netherlands)

    Reingruber, E.; Bedani, F.; Buchberger, W.; Schoenmakers, P.

    2010-01-01

    Gradient-elution liquid chromatography (GELC) is a powerful tool for the characterization of synthetic polymers. However, gradient-elution chromatograms often suffer from breakthrough phenomena. Breakthrough can be averted by using a sample solvent as weak as the mobile phase. However, this approach

  18. Deformation and degradation of polymers in ultra-high-pressure liquid chromatography

    NARCIS (Netherlands)

    Uliyanchenko, E.; van der Wal, S.; Schoenmakers, P.J.

    2011-01-01

    Ultra-high-pressure liquid chromatography (UHPLC) using columns packed with sub-2 μm particles has great potential for separations of many types of complex samples, including polymers. However, the application of UHPLC for the analysis of polymers meets some fundamental obstacles. Small particles an

  19. High throughput pyrogenic carbon (biochar) characterisation and quantification by liquid chromatography

    NARCIS (Netherlands)

    Cerqueira, W.V.; Rittl, T.F.; Novotny, E.H.; Pereira Netto, A.D.

    2015-01-01

    Characterisation and quantification of the carbonaceous polyaromatic structure of pyrogenic carbon (PyC) are of paramount importance to evaluate the role of PyC in soil carbon sequestration. A new method of rapid resolution liquid chromatography with UV diode array detection (RRLC-UV-DAD) was dev

  20. Determination of organophosphorus acids by thermo-spray liquid chromatography-mass spectrometry

    NARCIS (Netherlands)

    Wils, E.R.J.; Hulst, A.G.

    1988-01-01

    The determination of thirteen organophosphorus acids, hydrolysis products of nerve agents and pesticides, by a combination of ion-pair liquid chromatography on a reversed-phase C18 column and thermospray mass spectrometry was investigated. Ammonium acetate and three tetraalkylammonium salts with dif

  1. Analysis of Currently Available Analgesic Tablets by Modern Liquid Chromatography: An Undergraduate Laboratory Introduction to HPLC.

    Science.gov (United States)

    Kagel, R. A.; Farwell, S. O.

    1983-01-01

    Background information, procedures, and results, are provided for an undergraduate experiment in which analgesic tablets are analyzed using liquid chromatography. The experiment, an improved, modified version of the Waters Associates Inc. experiment, is simple to prepare, requiring little glassware and minimal sample manipulation by students. (JN)

  2. Extraction and Purification of Glucoraphanin by Preparative High-Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    Lee, Iris; Boyce, Mary C.

    2011-01-01

    A student activity that focuses on the isolation of glucoraphanin from broccoli using preparative high-performance liquid chromatography (HPLC) is presented here. Glucoraphanin is a glucosinolate, whose byproducts are known to possess anticancer properties. It is present naturally at high levels in broccoli and other "Brassica" vegetables. This…

  3. Determination of Peroxide-Based Explosives Using Liquid Chromatography with On-Line Infrared Detection

    NARCIS (Netherlands)

    Schulte-Ladbeck, Rasmus; Edelmann, Andrea; Quintas, Guillermo; Lendl, Bernhard; Karst, Uwe

    2006-01-01

    A nondestructive analytical method for peroxide-based explosives determination in solid samples is described. Reversed-phase high-performance liquid chromatography in combination with on-line Fourier transform infrared (FT-IR) detection is used for the analysis of triacetonetriperoxide (TATP) and he

  4. Benzoin Condensation: Monitoring a Chemical Reaction by High-Pressure Liquid Chromatography

    Science.gov (United States)

    Bhattacharya, Apurba; Purohit, Vikram C.; Bellar, Nicholas R.

    2004-01-01

    High-pressure liquid chromatography (HPLC) is the preferred method of separating a variety of materials in complex mixtures such as pharmaceuticals, polymers, soils, food products and biological fluids and is also considered to be a powerful analytical tool in both academia and industry. The use of HPLC analysis as a means of monitoring and…

  5. Gold nanoparticle decorated graphene oxide/silica composite stationary phase for high-performance liquid chromatography.

    Science.gov (United States)

    Liang, Xiaojing; Wang, Xusheng; Ren, Haixia; Jiang, Shengxiang; Wang, Licheng; Liu, Shujuan

    2014-06-01

    In the initial phase of this study, graphene oxide (GO)/silica was fabricated by assembling GO onto the silica particles, and then gold nanoparticles (GNPs) were used to modify the GO/silica to prepare a novel stationary phase for high-performance liquid chromatography. The new stationary phase could be used in both reversed-phase chromatography and hydrophilic interaction liquid chromatography modes. Good separations of alkylbenzenes, isomerides, amino acids, nucleosides, and nucleobases were achieved in both modes. Compared with the GO/silica phase and GNPs/silica phase, it is found that except for hydrophilicity, large π-electron systems, hydrophobicity, and coordination functions, this new stationary phase also exhibited special separation performance due to the combination of 2D GO with zero-dimensional GNPs.

  6. Validation of high-performance liquid chromatography (HPLC method for quantitative analysis of histamine in fish and fishery products

    Directory of Open Access Journals (Sweden)

    B.K.K.K. Jinadasa

    2016-12-01

    Full Text Available A high-performance liquid chromatography method is described for quantitative determination and validation of histamine in fish and fishery product samples. Histamine is extracted from fish/fishery products by homogenizing with tri-chloro acetic acid, separated with Amberlite CG-50 resin and C18-ODS Hypersil reversed phase column at ambient temperature (25°C. Linear standard curves with high correlation coefficients were obtained. An isocratic elution program was used; the total elution time was 10 min. The method was validated by assessing the following aspects; specificity, repeatability, reproducibility, linearity, recovery, limits of detection, limit of quantification and uncertainty. The validated parameters are in good agreement with method and it is a useful tool for determining histamine in fish and fishery products.

  7. Ultra performance liquid chromatography analysis to study the changes in the carotenoid profile of commercial monovarietal fruit juices.

    Science.gov (United States)

    Delpino-Rius, Antoni; Eras, Jordi; Marsol-Vall, Alexis; Vilaró, Francisca; Balcells, Mercè; Canela-Garayoa, Ramon

    2014-02-28

    We have developed an analytical method that allows the simultaneous determination of epoxycarotenoids, hydroxycarotenoids and carotenes in monovarietal fresh homemade and industrially processed fruit products. Analyses were carried out using ultra performance liquid chromatography (UPLC). The extraction method was optimized using methanol as the first extraction solvent for lyophilized samples followed by a saponification step. Recoveries ranged between 75% and 104% depending on the compound. Repeatability was better than 10% for all compounds (%RSD, n=3). The chromatographic analysis takes less than 17min. In this short period, up to 27 carotenoids were identified in apple, peach and pear products. The developed method allowed us to differentiate juice from six varieties of apple by their carotenoid profile. Moreover, the methodology allows us to differentiate the carotenoid profiles from commercial juices and homemade fresh peach and pear juices, as well as to study the rearrangements of 5,6- to 5,8-epoxycarotenoids.

  8. Simultaneous determination of 24 constituents in Cortex Lycii using high-performance liquid chromatography-triple quadrupole mass spectrometry.

    Science.gov (United States)

    Zhang, Jing-Xian; Guan, Shu-Hong; Yang, Min; Feng, Rui-Hong; Wang, Yang; Zhang, Yi-Bei; Chen, Xin; Chen, Xiao-Hui; Bi, Kai-Shun; Guo, De-An

    2013-04-15

    A fast high-performance liquid chromatography (HPLC) coupled with electrospray ionization (ESI) tandem mass spectrometry method was developed to determine 24 components including 11 phenolic compounds, 9 phenolic amides, and 4 cyclic peptides in Cortex Lycii. The analytes were quantified by a triple quadrupole instrument in multiple reaction monitoring (MRM) mode. The fragmentation patterns of phenolic amides and cyclic peptides using ESI and collision-induced dissociation (CID) techniques are reported. This assay method was validated with respect to linearity (r(2)>0.9920), precision, repeatability, and accuracy (recovery rate between 93.0 and 105.9% with RSDPrinciple component analysis (PCA) was used to discriminate samples from different geographical regions of China, and cyclic peptides were considered to be the chemical markers responsible for the classification. The systematic and integrated assessment of Cortex Lycii provides sufficient evidence for the establishment of the quality standard.

  9. Application of matrix solid-phase dispersion and high-performance liquid chromatography for determination of sulfonamides in honey.

    Science.gov (United States)

    Zou, Qiong-Hui; Wang, Jin; Wang, Xiang-Feng; Liu, Yuan; Han, Jie; Hou, Feier; Xie, Meng-Xia

    2008-01-01

    A novel method for simultaneous determination of 8 sulfonamide residues (sulfathiazole, sulfapyridine, sulfadiazine, sulfamerazine, sulfamonome-thoxine, sulfachloropyridazine, sulfamethoxazole, and sulfadimethoxine) in honey samples by high-performance liquid chromatography (HPLC) has been developed on the basis of precolumn derivatization with 9-fluorenylmethyl-chloroformate (FMOC-Cl). Sulfonamide residues in honey samples were extracted and purified by matrix solid-phase dispersion with C18 as the solid support. The residues were derivatized by FMOC-CI, and the FMOC-sulfonamide derivatives were further purified by solid-phase extraction with silica gel as the solid support prior to HPLC analysis. The average recoveries for most sulfonamide compounds at different spiking levels (from 10 to 250 microg/kg) were > 70% with relative standard deviations < 16%, and their limits of detection were 4.0 microg/kg. The established analytical method has high sensitivity and repeatability and can be applicable for determining the sulfonamide residues in various honey matrixes.

  10. Resolution of RNA using high-performance liquid chromatography

    NARCIS (Netherlands)

    Mclaughlin, L.W.; Bischoff, Rainer

    1987-01-01

    High-performance liquid chromatographic techniques can be very effective for the resolution and isolation of nucleic acids. The characteristic ionic (phosphodiesters) and hydrophobic (nucleobases) properties of RNAs can be exploited for their separation. In this respect anion-exchange and reversed-p

  11. Studies on Chromatography Fingerprint of Hongqi by High-performance Liquid Chromatography

    Institute of Scientific and Technical Information of China (English)

    Shi Lan FENG; Fang Di HU; Jian Xiong ZHAO; Jing Wen XU; Li Ren CHEN

    2004-01-01

    Chromatography fingerprint (CFP) of 10 samples of hongqi were studied. 23 common peaks were analyzed, their average similarity was 97.29%. CFP were positioned with main index composition such as formononetin, calycosin and then the contents of index composition were determined. The character and exclusive of CFP of 10 samples of hongqi were clear. CFP and content determination of index composition of hongqi could be used to evaluate the quality of hongqi comprehensively.

  12. Characterization of goat colostrum oligosaccharides by nano-liquid chromatography on chip quadrupole time-of-flight mass spectrometry and hydrophilic interaction liquid chromatography-quadrupole mass spectrometry.

    Science.gov (United States)

    Martín-Ortiz, A; Salcedo, J; Barile, D; Bunyatratchata, A; Moreno, F J; Martin-García, I; Clemente, A; Sanz, M L; Ruiz-Matute, A I

    2016-01-08

    A detailed qualitative and quantitative characterization of goat colostrum oligosaccharides (GCO) has been carried out for the first time. Defatted and deproteinized colostrum samples, previously treated by size exclusion chromatography (SEC) to remove lactose, were analyzed by nanoflow liquid chromatography-quadrupole-time of flight mass spectrometry (Nano-LC-Chip-Q-TOF MS). Up to 78 oligosaccharides containing hexose, hexosamine, fucose, N-acetylneuraminic acid or N-glycolylneuraminic acid monomeric units were identified in the samples, some of them detected for the first time in goat colostra. As a second step, a hydrophilic interaction liquid chromatography coupled to mass spectrometry (HILIC-MS) methodology was developed for the separation and quantitation of the main GCO, both acidic and neutral carbohydrates. Among other experimental chromatographic conditions, mobile phase additives and column temperature were evaluated in terms of retention time, resolution, peak width and symmetry of target carbohydrates. Narrow peaks (wh: 0.2-0.6min) and good symmetry (As: 0.8-1.4) were obtained for GCO using an acetonitrile:water gradient with 0.1% ammonium hydroxide at 40°C. These conditions were selected to quantify the main oligosaccharides in goat colostrum samples. Values ranging from 140 to 315mgL(-1) for neutral oligosaccharides and from 83 to 251mgL(-1) for acidic oligosaccharides were found. The combination of both techniques resulted to be useful to achieve a comprehensive characterization of GCO.

  13. Rapid, simple and stability-indicating determination of polyhexamethylene biguanide in liquid and gel-like dosage forms by liquid chromatography with diode-array detection

    Institute of Scientific and Technical Information of China (English)

    Markus Küsters; Sören Beyer; Stephan Kutscher; Harald Schlesinger; Michael Gerhartz

    2013-01-01

    A rapid and simple method for the determination of polyhexamethylene biguanide (polyhexanide, PHMB) in liquid and gel-like pharmaceutical formulations by means of high performance liquid chromatography coupled to diode-array detection (HPLC-DAD) was developed. Best separation was achieved using a cyanopropyl bonded phase (Agilent Zorbax Eclipse XDB-CN column 4.6 mm75 mm with particle size of 3.5 mm) as well as gradient elution consisting of acetonitrile/deionized water at a flow rate of 1.0 mL/min. The optimized and applied chromatographic conditions permitted separation of polyhexanide from interacting matrix with subsequent detection at a wavelength of 235 nm with good sensitivity. The method validation was carried out with regard to the guidelines for analytical procedures demanded by the International Conference on Harmonisation (ICH). Mean recoveries of 102% and 101% for gel-like as well as liquid preparations were obtained. Suitable repeatability as well as intermediate precision could be achieved with limits of detection r0.004 mg/mL for both formulations, equivalent to r0.004% PHMB concerning sample preparation. Determination of PHMB was accomplished without tedious sample preparation. Interacting matrix could be eliminated by the chromatographic procedure with excellent performance of system suitability. All analytical requirements were fulfilled permitting a reliable and precise determination of PHMB in pharmaceuticals. Furthermore, the developed method was applied to stability testing of pharmaceutical preparations containing PHMB.

  14. Review of in situ derivatization techniques for enhanced bioanalysis using liquid chromatography with mass spectrometry.

    Science.gov (United States)

    Baghdady, Yehia Z; Schug, Kevin A

    2016-01-01

    Accurate and specific analysis of target molecules in complex biological matrices remains a significant challenge, especially when ultra-trace detection limits are required. Liquid chromatography with mass spectrometry is often the method of choice for bioanalysis. Conventional sample preparation and clean-up methods prior to the analysis of biological fluids such as liquid-liquid extraction, solid-phase extraction, or protein precipitation are time-consuming, tedious, and can negatively affect target recovery and detection sensitivity. An alternative or complementary strategy is the use of an off-line or on-line in situ derivatization technique. In situ derivatization can be incorporated to directly derivatize target analytes in their native biological matrices, without any prior sample clean-up methods, to substitute or even enhance the extraction and preconcentration efficiency of these traditional sample preparation methods. Designed appropriately, it can reduce the number of sample preparation steps necessary prior to analysis. Moreover, in situ derivatization can be used to enhance the performance of the developed liquid chromatography with mass spectrometry-based bioanalysis methods regarding stability, chromatographic separation, selectivity, and ionization efficiency. This review presents an overview of the commonly used in situ derivatization techniques coupled to liquid chromatography with mass spectrometry-based bioanalysis to guide and to stimulate future research.

  15. Human pharmacokinetics of the muscle relaxant, eperisone hydrochloride by liquid chromatography-electrospray tandem mass spectrometry.

    Science.gov (United States)

    Melilli, Barbara; Piazza, Cateno; Vitale, Daniela Cristina; Marano, Maria Rosa; Pecori, Andrea; Mattana, Paolo; Volsi, Valentina Li; Iuculano, Carmelo; Cardì, Francesco; Drago, Filippo

    2011-06-01

    Eperisone hydrochloride (4'-ethyl-2-methyl-3-piperidinopropiophenone hydrochloride) is a muscle relaxant agent, widely used in the treatment of patients with muscular contractures, low back pain or spasticity. Because of its mechanism of action (inhibition of gamma-efferent firing and local vasodilatation activity), side effects on central nervous system are rarely observed. A sensitive liquid chromatography-electrospray ionization-mass spectrometry method for determination of eperisone in human plasma has been developed, with a lower limit of quantification of 0.01 ng/mL. The method was applied to a pharmacokinetic study in 12 healthy volunteers given eperisone 100 mg as single dose on day 1 and three times daily on days 2 to 4. Eperisone was rapidly absorbed after oral administration (T (max) = 1.6 h) as it was expected by its fast-onset relaxant activity. Moreover, eperisone underwent a rapid elimination from the body (biological half-life 1.87 h), which was not modified during the repeated dosing as suggested by the C (max) cumulation observed, not different from that expected for a t (1/2) of 1.87 h as suggested by the similar and negligible plasma concentration values (0.063 and 0.067 ng/mL) measured on day 4 before the morning dose and 12 h after evening dose, thus ruling out any potential risk for drug accumulation. Thus, the pharmacokinetic characteristics of eperisone provide further justification for its tolerability in patients with low back pain or spastic palsy, in which the drug is given for periods ranging from few days to several months, respectively.

  16. Determination of testosterone in serum by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Turpeinen, U; Linko, S; Itkonen, O; Hämäläinen, E

    2008-01-01

    Commercial direct immunoassays for serum testosterone sometimes result in inaccuracies in samples from women and children, leading to misdiagnosis and inappropriate treatment. The diagnosis of male hypogonadism also requires an accurate testosterone assay method. We therefore developed a sensitive and specific stable-isotope dilution liquid chromatography-tandem mass spectrometric (LC-MS/MS) method for serum testosterone at the concentrations encountered in women and children. Testosterone was extracted with ether-ethyl acetate from 250 microL or 500 microL of serum. Instrumental analysis was performed on an API 2000 tandem mass spectrometer in the multiple-reaction monitoring (MRM) mode after separation on a reversed-phase column. The MRM transitions (m/z) were 289/97 for testosterone and 291/99 for d(2) testosterone. The calibration curves exhibited consistent linearity and repeatability in the range 0.2-100 nmol/L. Interassay CVs were 4.2-7.6 % at mean concentrations of testosterone of 3.3-45 nmol/L. Total measurement uncertainty (U, k = 2) was 12.9 % and 13.4 % at testosterone levels of 2.0 nmol/L and 20 nmol/L, respectively. The limit of detection was 0.05 nmol/L (signal-to-noise ratio = 3) and the overall method recovery of testosterone was 95 %. Correlation (r) with our in-house extraction RIA was 0.98 and with a commercial RIA 0.92. Reference intervals for adult males and females in age groups 18-30, 31-50, 51-70 and over 70 years were established. Sensitivity and specificity of the LC-MS/MS method offer advantages over immunoassay and make it suitable for use as a high-throughput assay in routine clinical laboratories. The high equipment costs are balanced by higher throughput together with shorter chromatographic run times.

  17. Assessment of radiochemical purity of [{sup 18}F]fludeoxyglucose by high pressure liquid chromatography (HPLC)

    Energy Technology Data Exchange (ETDEWEB)

    Lacerda, Aline E.; Silva, Juliana B.; Silveira, Marina B.; Ferreira, Soraya Z., E-mail: radiofarmacoscdtn@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Unidade de Pesquisa e Producao de Radiofarmacos

    2011-07-01

    The quality control of [{sup 18}F]fludeoxyglucose ({sup 18}FDG) has received attention due to its increasing clinical use. Although the quality requirements of {sup 18}FDG are established in various pharmacopoeia, the suitability of all testing methods used should be verified under actual conditions of use and documented. The aim of this study was to develop a high pressure liquid chromatography (HPLC) method for radiochemical purity evaluation of {sup 18}FDG, based on pharmacopoeia references, and to verify its suitability for routine quality control in our centre. HPLC analysis was performed with an Agilent HPLC. {sup 18}FDG and impurities were separated on an anion-exchange column by isocratic elution with 0.1 M NaOH as the mobile phase. Detection was accomplished with refractive index and NaI (Tl) scintillation detectors. The flow rate of the mobile phase was set at 0.8 mL/min and the column temperature was kept at 35 deg C. Specificity, linearity, precision and robustness were assessed to verify if the method was adequate for its intended purpose. Retention time of {sup 18}FDG was not affected by the presence of other components of the formulation and a good peak resolution was achieved. The analytical curve of {sup 18}FDG was linear, with a correlation coefficient value of 0.9995. Intraday repeatable precision, reported as the relative standard deviation, was 0.11%. Analytical procedure remained unaffected by small variations in mobile phase flow rate. Results evidenced that HPLC is suitable for radiochemical purity evaluation of {sup 18}FDG, considering operational conditions of our laboratory. (author)

  18. Analysis of synthetic cannabinoids in herbal blends by means of nano-liquid chromatography.

    Science.gov (United States)

    Merola, Gustavo; Aturki, Zeineb; D'Orazio, Giovanni; Gottardo, Rossella; Macchia, Teodora; Tagliaro, Franco; Fanali, Salvatore

    2012-12-01

    In this study, a rapid and simultaneous separation of 12 synthetic cannabinoids and Δ(9)-tetrahydrocannabinol (Δ(9)-THC) in herbal blends was obtained by means of nano-liquid chromatography (nano-LC). The nano-LC experiments were performed in a 100μm i.d. capillary column packed with Cogent(®) bidentate C(18) silica particles for 25.0cm. All compounds were resolved using an isocratic elution mode in less than 30min. A mobile phase containing ACN/MeOH/H(2)O/formic acid 69/5/25/1 (v/v/v/v) was employed for the chromatographic separation. The developed analytical method was validated in terms of precision, linearity, sensitivity and accuracy. Under optimal nano-LC-UV conditions, the resulting RSD percentages for intra-day and inter-day repeatability, related to retention time and peak area, were below 2.98 and 6.40%, respectively. Limits of detection and quantification were 0.2 and 0.5μg/mL, respectively, for all the studied compounds. Linearity was assessed in the concentration range of interest for all analytes with determination coefficients r(2)≥0.9975. The method was then applied to the determination of synthetic cannabinoids in herbal blends. Quantitative analyses of the cannabimimetic compounds in six products showed that there was a wide difference in the concentration of the studied compounds among different products. Further, the nano-LC system was coupled with a mass spectrometer measuring the MS and MS-MS spectra to unequivocally identify the cannabinoids present in smoking mixtures.

  19. Capillary liquid chromatography-microchip atmospheric pressure chemical ionization-mass spectrometry.

    Science.gov (United States)

    Ostman, Pekka; Jäntti, Sirkku; Grigoras, Kestas; Saarela, Ville; Ketola, Raimo A; Franssila, Sami; Kotiaho, Tapio; Kostiainen, Risto

    2006-07-01

    A miniaturized nebulizer chip for capillary liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (capillary LC-microchip APCI-MS) is presented. The APCI chip consists of two wafers, a silicon wafer and a Pyrex glass wafer. The silicon wafer has a DRIE etched through-wafer nebulizer gas inlet, an edge capillary insertion channel, a stopper, a vaporizer channel and a nozzle. The platinum heater electrode and pads for electrical connection were patterned on to the Pyrex glass wafer. The two wafers were joined by anodic bonding, creating a microchip version of an APCI-source. The sample inlet capillary from an LC column is directly connected to the vaporizer channel of the APCI chip. The etched nozzle in the microchip forms a narrow sample plume, which is ionized by an external corona needle, and the formed ions are analyzed by a mass spectrometer. The nebulizer chip enables for the first time the use of low flow rate separation techniques with APCI-MS. The performance of capillary LC-microchip APCI-MS was tested with selected neurosteroids. The capillary LC-microchip APCI-MS provides quantitative repeatability and good linearity. The limits of detection (LOD) with a signal-to-noise ratio (S/N) of 3 in MS/MS mode for the selected neurosteroids were 20-1000 fmol (10-500 nmol l(-1)). LODs (S/N = 3) with commercial macro APCI with the same compounds using the same MS were about 10 times higher. Fast heat transfer allows the use of the optimized temperature for each compound during an LC run. The microchip APCI-source provides a convenient and easy method to combine capillary LC to any API-MS equipped with an APCI source. The advantages and potentials of the microchip APCI also make it a very attractive interface in microfluidic APCI-MS.

  20. Ultra-high-performance liquid chromatography profiling method for chemical screening of proanthocyanidins in Czech hops.

    Science.gov (United States)

    Olšovská, J; Kameník, Z; Čejka, P; Jurková, M; Mikyška, A

    2013-11-15

    Hops represent an important natural source of bioactive polyphenols, particularly proanthocyanidins, which can contribute to prevention of several civilization diseases, owing to their antioxidant and radical scavenging activity. We have developed a high-throughput ultra-high-performance liquid chromatography time-of-flight mass spectrometry profiling method, which can be used for monitoring of bioactive proanthocyanidins in hops. The method was applied for analysis of hops of four Czech varieties (Saaz, Sladek, Preminat and Agnus) from the 2011 crop (9 localities, 11 samples) and the 2012 crop (24 localities, 40 samples). Hop samples were extracted by acetone and the analytes were separated on the Acquity UPLC BEH Shield RP18 column. Partial validation of the method revealed a satisfactory intra-day repeatability of the method for retention times (relative standard deviation within 1.39%) as well as areas under the peaks (within 9.89%). Experimental data were evaluated using principal component analysis and cluster analysis. Significant amounts of di-, tri- and tetramer proanthocyanidins consisting of (epi)catechin and (epi)gallocatechin were found in the hop samples. The dependence of the proantocyanidin composition on both the variety and the growing locality was observed. Specifically, the traditional Saaz variety contained more frequently oligomers formed by (epi)catechin units only, whereas the varieties Premiant and Agnus produced oligomers consisting of (epi)catechin as well as (epi)gallocatechin units. The relative abundance of proanthocyanidins in studied hop varieties from the two crops, 2011 and 2012, did correspond to each other. In the further perspective, the method may also be used for prediction of qualitative marks or authenticity verification of hops.

  1. Highly sensitive detection of melamine based on reversed phase liquid chromatography mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    WU QingQing; FAN KeXin; SHA Wei; RUAN HongQiang; ZENG Rong; SHIEH ChiaHui

    2009-01-01

    In this work, we developed a highly sensitive method to detect melamine based on reversed phase liquid chromatography mass spectrometry. A mass spectrometry compatible ion pair, heptafluorobu-tyric acid(HFBA), was used to separate melamine by reversed phase liquid chromatography prior to electrospray mass spectrometry. The incorporation of isotope internal standard and multiple reaction monitoring improved the accuracy and linearity of quantification. Based on this strategy, the method limit of quantification was 0.1 ng/g. The limits of quantification were 8 ng/g for liquid milk and 15 ng/g for dry milk powder. This method provided a reproducible and stable approach to sensitive detection and quantification of melamine.

  2. Two-dimensional liquid chromatography analysis of synthetic polymers using fast size exclusion chromatography at high column temperature.

    Science.gov (United States)

    Im, Kyuhyun; Park, Hae-Woong; Lee, Sekyung; Chang, Taihyun

    2009-05-22

    In recent years, two-dimensional liquid chromatography (2D-LC) has been used increasingly for the analysis of synthetic polymers. A 2D-LC analysis provides richer information than a single chromatography analysis at the cost of longer analysis time. The time required for a comprehensive 2D-LC analysis is essentially proportional to the analysis time of the second dimension separation. Many of 2D-LC analyses of synthetic polymers have employed size exclusion chromatography (SEC) for the second-dimension analysis due to the relatively short analysis time in addition to the wide use in the polymer analysis. Nonetheless, short SEC columns are often used for 2D-LC analyses to reduce the separation time, which inevitably deteriorates the resolution. In this study, we demonstrated that high temperature SEC can be employed as an efficient second-LC in the 2D-LC separation of synthetic polymers. By virtue of high temperature operation (low solvent viscosity and high diffusivity of the polymer molecules), a normal length SEC column can be used at high flow rate with little loss in resolution.

  3. Hyphenated and comprehensive liquid chromatography × gas chromatography-mass spectrometry for the identification of Mycobacterium tuberculosis.

    Science.gov (United States)

    Mourão, Marta P B; Denekamp, Ilse; Kuijper, Sjoukje; Kolk, Arend H J; Janssen, Hans-Gerd

    2016-03-25

    Tuberculosis is one of the world's most emerging public health problems, particularly in developing countries. Chromatography based methods have been used to tackle this epidemic by focusing on biomarker detection. Unfortunately, interferences from lipids in the sputum matrix, particularly cholesterol, adversely affect the identification and detection of the marker compounds. The present contribution describes the serial combination of normal phase liquid chromatography (NPLC) with thermally assisted hydrolysis and methylation followed by gas chromatography-mass spectrometry (THM-GC-MS) to overcome the difficulties of biomarker evaluation. The in-series combination consists of an LC analysis where fractions are collected and then transferred to the THM-GC-MS system. This was either done with comprehensive coupling, transferring all the fractions, or with hyphenated interfacing, i.e. off-line multi heart-cutting, transferring only selected fractions. Owing to the high sensitivity and selectivity of LC as a sample pre-treatment method, and to the high specificity of the MS as a detector, this analytical approach, NPLC × THM-GC-MS, is extremely sensitive. The results obtained indicate that this analytical set-up is able to detect down to 1 × 10(3) mycobacteria/mL of Mycobacterium tuberculosis strain 124, spiked in blank sputum samples. It is a powerful analytical tool and also has great potential for full automation. If further studies demonstrate its usefulness when applied blind in real sputum specimens, this technique could compete with the current smear microscopy in the early diagnosis of tuberculosis.

  4. Separation of carbohydrates using hydrophilic interaction liquid chromatography.

    Science.gov (United States)

    Fu, Qing; Liang, Tu; Li, Zhenyu; Xu, Xiaoyong; Ke, Yanxiong; Jin, Yu; Liang, Xinmiao

    2013-09-20

    A strategy was developed to rapidly evaluate chromatographic properties of hydrophilic interaction chromatography (HILIC) columns for separating carbohydrates. Seven HILIC columns (Silica, Diol, TSK Amide-80, XAmide, Click Maltose, Click β-CD, and Click TE-Cys columns) were evaluated by using three monosaccharide and seven disaccharides as probes. The influence of column temperature on the peak shape and tautomerization of carbohydrates, as well as column selectivity were investigated. The influence of surface charge property on the retention was also studied by using glucose, glucuronic acid, and glucosamine, which indicated that buffer salt concentration and pH value in mobile phase was necessary to control the ionic interactions between ionic carbohydrates and HILIC columns. According to evaluation results, the XAmide column was selected as an example to establish experimental schemes for separation of complex mixtures of oligosaccharide.

  5. Liquid chromatography-tandem mass spectrometric assay for the tyrosine kinase inhibitor afatinib in mouse plasma using salting-out liquid-liquid extraction

    NARCIS (Netherlands)

    Sparidans, Rolf W; van Hoppe, Stephanie; Rood, Johannes J M; Schinkel, Alfred H; Schellens, Jan H M; Beijnen, Jos H

    2016-01-01

    A quantitative bioanalytical liquid chromatography-tandem mass spectrometric (LC-MS/MS) assay for afatinib, an irreversible inhibitor of the ErbB (erythroblastic leukemia viral oncogene homolog) tyrosine kinase family, was developed and validated. Plasma samples were pre-treated using salting-out as

  6. Highly specific quantification of ergotamine in urine, blood, and hair samples by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Favretto, Donata; Frison, Giampietro; Vogliardi, Susanna; Ferrara, Santo Davide

    2007-06-01

    Ergotamine has been used for therapeutic purposes since the 1950s, usually to treat vascular headache. It is highly toxic and in large, repeated doses can produce all the symptoms of ergot poisoning. A selective and sensitive method, based on liquid chromatography-tandem mass spectrometry (LC-MS2), has been developed for quantifying ergotamine in biological fluids with use of a quick and easy sample preparation. Ergotamine and the internal standard, trideuterated lysergic acid diethylamide, were extracted from human urine, blood, and hair by means of liquid-liquid extraction at alkaline pH. Gradient elution on a cyanopropyl column was used for chromatographic separation. Positive ion electrospray ionization and tandem mass spectrometry determination by collision-induced dissociation were performed in an ion trap mass spectrometer. The method was validated and successfully applied to a case of iatrogenic ergotism resulting from the intake of ergotamine tartrate for treating headache. For the first time, ergotamine was identified and quantified in hair. The ergotamine concentrations measured were 320 pg/mL in blood, 100 pg/mL in urine, 24 pg/mg in proximal hair, and 15 pg/mg in distal hair.

  7. Ultra-performance liquid chromatography-tandem mass spectrometry method for the analysis of amphetamines in plasma.

    Science.gov (United States)

    Fernández, María del Mar Ramírez; Samyn, Nele

    2011-10-01

    A fast and selective ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS-MS) method for the determination of amphetamines (amphetamine, methamphetamine, methylenedioxymethamphetamine, methylenedioxyamphetamine, methylenedioxyethylamphetamine, ephedrine, and p-methoxyamphetamine) in plasma has been developed and validated. Sample preparation was performed by liquid-liquid extraction using ethyl acetate. For optimized chromatographic performance with repeatable retention times, narrow and symmetrical peaks, and focusing all analytes at the column inlet, a gradient start, with acid mobile phase consisting of 0.1% formic acid and methanol was chosen. Positive electrospray ionization MS-MS detection was performed with two multiple reaction monitoring transitions for each analyte. Deuteriumlabeled internal standards were used for five of the analytes. The limit of detection was in the range 0.25-1.25 ng/mL, and the limit of quantification was fixed at the lowest calibrator of 2.5 ng/mL for all of the compounds. The RSD values of the intra- and interassay precision and accuracy were lower than 11% at four concentration levels, including two external quality controls. No or only minor matrix effects were observed, and the extraction method presented recoveries higher than 93% for all the compounds. Total run time, including equilibration, was 12 min. The method is routinely used at the National Institute of Criminalistics and Criminology for quantitative determination of the main amphetamines in plasma from forensic and driving under the influence cases.

  8. Design and implementation of an automated liquid-phase microextraction-chip system coupled on-line with high performance liquid chromatography.

    Science.gov (United States)

    Li, Bin; Petersen, Nickolaj Jacob; Payán, María D Ramos; Hansen, Steen Honoré; Pedersen-Bjergaard, Stig

    2014-03-01

    An automated liquid-phase microextraction (LPME) device in a chip format has been developed and coupled directly to high performance liquid chromatography (HPLC). A 10-port 2-position switching valve was used to hyphenate the LPME-chip with the HPLC autosampler, and to collect the extracted analytes, which then were delivered to the HPLC column. The LPME-chip-HPLC system was completely automated and controlled by the software of the HPLC instrument. The performance of this system was demonstrated with five alkaloids i.e. morphine, codeine, thebaine, papaverine, and noscapine as model analytes. The composition of the supported liquid membrane (SLM) and carrier was optimized in order to achieve reasonable extraction performance of all the five alkaloids. With 1-octanol as SLM solvent and with 25 mM sodium octanoate as anionic carrier, extraction recoveries for the different opium alkaloids ranged between 17% and 45%. The extraction provided high selectivity, and no interfering peaks in the chromatograms were observed when applied to human urine samples spiked with alkaloids. The detection limits using UV-detection were in the range of 1-21 ng/mL for the five opium alkaloids presented in water samples. The repeatability was within 5.0-10.8% (RSD). The membrane liquid in the LPME-chip was regenerated automatically between every third injection. With this procedure the liquid membrane in the LPME-chip was stable in 3-7 days depending on the complexity of sample solutions with continuous operation. With this LPME-chip-HPLC system, series of samples were automatically injected, extracted, separated, and detected without any operator interaction.

  9. Binary Solvents Dispersive Liquid—Liquid Microextraction (BS-DLLME) Method for Determination of Tramadol in Urine Using High-Performance Liquid Chromatography

    Science.gov (United States)

    2014-01-01

    Background Tramadol is an opioid, synthetic analog of codeine and has been used for the treatment of acute or chronic pain may be abused. In this work, a developed Dispersive liquid liquid microextraction (DLLME) as binary solvents-based dispersive liquid-liquid microextraction (BS-DLLME) combined with high performance liquid chromatography (HPLC) with fluorescence detection (FD) was employed for determination of tramadol in the urine samples. This procedure involves the use of an appropriate mixture of binary extraction solvents (70 μL CHCl3 and 30 μL ethyl acetate) and disperser solvent (600 μL acetone) for the formation of cloudy solution in 5 ml urine sample comprising tramadol and NaCl (7.5%, w/v). After centrifuging, the small droplets of extraction solvents were precipitated. In the final step, the HPLC with fluorescence detection was used for determination of tramadol in the precipitated phase. Results Various factors on the efficiency of the proposed procedure were investigated and optimized. The detection limit (S/N = 3) and quantification limit (S/N = 10) were found 0.2 and 0.9 μg/L, respectively. The relative standard deviations (RSD) for the extraction of 30 μg L of tramadol was found 4.1% (n = 6). The relative recoveries of tramadol from urine samples at spiking levels of 10, 30 and 60 μg/L were in the range of 95.6 – 99.6%. Conclusions Compared with other methods, this method provides good figures of merit such as good repeatability, high extraction efficiency, short analysis time, simple procedure and can be used as microextraction technique for routine analysis in clinical laboratories. PMID:24495475

  10. Isolation and purification of uremic middle molecules by multi-step liquid chromatography

    Institute of Scientific and Technical Information of China (English)

    储结根; 刘晓航; 袁直; 何炳林

    2002-01-01

    Isolation and comparison of uremic sera and urine and normal sera and urine were performed by gel permeation chromatography, anion exchange chromatography and reversed-phase high performance liquid chromatography. Two uremic middle molecular fractions (A and B) were obtained from uremic sera and urine and normal urine by gel permeation chromatography, but not from normal sera. The anion exchange chromatographic results of fraction A from different origins demonstrate that subfraction A-3 could be excreted in urine by healthy subject, but accumulated in uremic serum for renal failure of patient with uremia. After desalinization subfraction A-3 was analyzed by MALDI-TOF-MS. The results show that subfraction A-3 consists of six compounds with molecular weight 839, 873, 1007.94, 1106, 1680 and 2015 respectively. Finally, by reversed-phase high performance liquid chromatography, subfraction A-3 was further resolved into six independent fractions. Thus, the isolation and purification of six middle molecular compounds in subfraction A-3 came true by our method.

  11. Characterization of sodium carboxymethyl cellulose by comprehensive two-dimensional liquid chromatography.

    Science.gov (United States)

    Shakun, Maria; Heinze, Thomas; Radke, Wolfgang

    2015-10-05

    Two series of sodium carboxymethyl celluloses (NaCMC) with average degrees of substitution (DS) ranging from 0.45 to 1.55 were synthesized from low molecular mass Avicel cellulose (Avicel samples) and from high molecular mass cotton linters (BWL samples). The samples were characterized by online two-dimensional liquid chromatography using gradient liquid adsorption chromatography in the first and size exclusion chromatography (SEC) in the second dimension. This method allows the simultaneous determination of the chemical composition (DS) and the molar mass distribution within the individual samples. Moreover information was obtained on the dependence of the elution volume in gradient chromatography on molar mass. As expected, evidence for a stronger influence of molar mass on gradient elution volume was found for the low molecular mass NaCMC as compared to the high molecular mass BWL samples. Finally the applicability of the method for the simultaneous separation of blends heterogeneous with respect to chemical composition (DS) and molar mass was demonstrated. Such blends cannot be efficiently separated by either SEC or gradient chromatography alone, nor by simply combining the results of both methods. Only the complete two-dimensional chromatogram can reveal the complexity of such blends, since it reveals the correlations between molar mass and chemical composition.

  12. Background vapor from six ionic liquids and the partition coefficients and limits of detection for 10 different analytes in those ionic liquids measured using headspace gas chromatography.

    Science.gov (United States)

    Von Wald, Grant; Albers, David; Cortes, Hernan; McCabe, Terry

    2008-08-01

    The concentration and identity of the compounds detected in the vapor above six ionic liquids by headspace gas chromatography (HS-GC) at 100 degrees C are reported. In addition, the partition coefficients for 10 different compounds in these ionic liquids and limits of detection were measured. These results provide quantitative guidance for the application of ionic liquids for HS-GC.

  13. Graphene reflux: improving the yield of liquid-exfoliated nanosheets through repeated separation techniques

    Science.gov (United States)

    Rountree, Kyler S.; Shah, Smit A.; Sweeney, Charles B.; Irin, Fahmida; Green, Micah J.

    2016-12-01

    Scalable production of graphene through liquid-phase exfoliation has been plagued by low yields. Although several recent studies have attempted to improve graphene exfoliation technology, the problem of separating colloidal nanosheets from unexfoliated parent material has received far less attention. Here we demonstrate a scalable method for improving nanosheet yield through a facile washing process. By probing the sedimentation of liquid-phase exfoliated slurries of graphene nanosheets and parent material, we found that a portion of exfoliated graphene is entrapped in the sediment, but can be recovered by repeatedly washing the slurry of nanosheet and parent material with additional solvent. We found this process to significantly increase the overall yield of graphene (graphene/parent material) and recover a roughly constant proportion of graphene with each wash. The cumulative amount of graphene recovered is only a function of total solvent volume. Moreover, we found this technique to be applicable to other types of nanosheets such as boron nitride nanosheets.

  14. Gas and high-performance liquid chromatography of phenols

    Energy Technology Data Exchange (ETDEWEB)

    Tesarova, E.; Pacakova, V.

    1983-05-01

    Gas (GC) and high-performance liquid chromatographic (HPLC) methods in the analysis of phenols are reviewed. Among the great number of phenolic compounds analyzed, alkylphenols, chlorophenols, dihydroxy-and trihydroxy-benzenes and biphenols are chiefly considered. The advantages and drawbacks of the methods are discussed. Relationships between the structural characteristics of phenols, the stationary phase structure, the mobile phase composition and the retention data are treated. Typical examples of the conditions for GC and HPLC analysis are summarized in tables. 276 references

  15. Rapid analysis of phentolamine by high-performance liquid chromatography.

    Science.gov (United States)

    Webster, Gregory K; Lemmer, Robert R; Greenwald, Steven

    2003-02-01

    A rapid liquid chromatographic method is validated for the quantitative analysis of phentolamine. Phentolamine exists in three forms for this investigation: as a mesylate salt, hydrochloride salt, and free base. In solution, phentolamine dissociates from its salt and is chromatographed as free phentolamine. This validation confirms the analysis of each form, which is simply based upon molar mass differences encountered in weighing. As such, both the United States Pharmacopeia hydrochloride and mesylate standards are used throughout this validation to demonstrate this equivalency. The validation demonstrates that this method may be used to quantitate phentolamine, regardless of its salt form.

  16. Determination of methylphenidate in Calliphorid larvae by liquid-liquid extraction and liquid chromatography mass spectrometry - Forensic entomotoxicology using an in vivo rat brain model

    DEFF Research Database (Denmark)

    Bushby, Sarah K.; Thomas, Nicky; Priemel, Petra A.;

    2012-01-01

    and Calliphorid larvae) by liquid-liquid extraction with recovery of >80%, and quantified using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The LC-MS/MS assay was validated for entomotoxicological use and initially applied to male Sprague-Dawley rats (n=6) that were dosed with MPH (20mg/kg) ante......The aim of this study was to examine the potential forensic utilisation of blowfly larvae (Diptera: Calliphoridae) as an alternative toxicological specimen for the detection of the psychotropic model drug methylphenidate (MPH). MPH was extracted from biological matrices (rat brain, serum...

  17. Simultaneous determination of seven anticoagulant rodenticides in agricultural products by gel permeation chromatography and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Saito-Shida, Shizuka; Nemoto, Satoru; Matsuda, Rieko; Akiyama, Hiroshi

    2016-11-01

    A sensitive and reliable method for the simultaneous determination of hydroxycoumarin-type (brodifacoum, bromadiolone, coumatetralyl, and warfarin) and indandione-type (chlorophacinone, diphacinone, and pindone) rodenticides in agricultural products by gel permeation chromatography (GPC) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed. The procedure involved extraction of the rodenticides from samples with acetone, followed by liquid-liquid partitioning with hexane/ethyl acetate (1:1, v/v) and 10% sodium chloride aqueous solution, then cleanup using GPC, and finally, analysis using LC-MS/MS. High recoveries from the GPC column were obtained for all rodenticides tested using a mobile phase of acetone/cyclohexane/triethylamine (400:1600:1, v/v/v). An ODS column, which contains low levels of metal impurities, gave satisfactory peak shapes for both hydroxycoumarin- and indandione-type rodenticides in the LC-MS/MS separation. The average recoveries of rodenticides from eight agricultural foods (apple, eggplant, cabbage, orange, potato, tomato, brown rice, and soybean) fortified at 0.0005-0.001 mg/kg ranged from 76 to 116%, except for bromadiolone in orange (53%) and diphacinone in soybean (54%), and the relative standard deviations ranged from 1 to 16%. The proposed method effectively removed interfering components, such as pigments and lipids, and showed high selectivity. In addition, the matrix effects were negligible for most of the rodenticide/food combinations. The results suggest that the proposed method is reliable and suitable for determining hydroxycoumarin- and indandione-type rodenticides in agricultural products.

  18. Determination of 1-hydroxypyrene in human urine by high-performance liquid chromatography

    DEFF Research Database (Denmark)

    Hansen, Åse Marie; Poulsen, O M; Christensen, J M

    1993-01-01

    A high-performance liquid chromatography (HPLC)/fluorescence method for quantitative analysis of 1-hydroxypyrene in urine was developed. The method validation analysis showed the method to be in analytical control. No significant systematical errors could be demonstrated. The entire run time...... of chromatography was 10 min using isocratic elution (acetonitrile-water, 70:30), and the retention time for 1-hydroxypyrene was 3.5 min. The short run time in combination with the low limit detection (1.37 nmol/L) makes the method potentially applicable for surveillance of pyrene exposure in work environments...

  19. APPLICATIONS OF CERIUM BIS (MONOMYRISTY—LPHOSPHATE)ADSORBENT TO REVERSED PHASE LIQUID CHROMATOGRAPHY

    Institute of Scientific and Technical Information of China (English)

    SuZhengquan; FengHuixia; 等

    1996-01-01

    The tetravalent metal salts of monoalkyl phosphates [M(O3POR)2]are a new kind of stationary phases of Chromatography-homogeneous bonded phases.This paper deals with the application of cerium bis(monomyristylphosphate)as support to reversed phase liquid chromatography.The results show that the best mobil phase is CH3CN:H2O=95:5.The good separation to the mixture containing six aromatic hydrocarbons and the determination of naphthalene in a group samples have been achieved.The regression analysis shows that detect limits,linearities and precision for six aromatic hydrocarbons are good.

  20. Lattice-fluid model for gas-liquid chromatography.

    Science.gov (United States)

    Tao, Y; Wells, P S; Yi, X; Yun, K S; Parcher, J F

    1999-11-01

    Lattice-fluid models describe molecular ensembles in terms of the number of lattice sites occupied by molecular species (r-mers) and the interactions between neighboring molecules. The lattice-fluid model proposed by Sanchez and Lacombe (Macromolecules, 1978;11:1145-1156) was used to model specific retention volume data for a series of n-alkane solutes with n-alkane, polystyrene, and poly(dimethylsiloxane) stationary liquid phases. Theoretical equations were derived for the specific retention volume and also for the temperature dependence and limiting (high temperature) values for the specific retention volume. The model was used to predict retention volumes within 10% for the n-alkanes phases; 22% for polystyrene; and from 20 to 70% for PDMS using no adjustable parameters. The temperature derivative (enthalpy) could be calculated within 5% for all of the solutes in nine stationary liquid phases. The limiting value for the specific retention volume at high temperature (entropy controlled state) could be calculated within 10% for all of the systems. The limiting data also provided a new chromatographic method to measure the size parameter, r, for any chromatographic solute using characteristic and size parameters for the stationary phase only. The calculated size parameters of the solutes were consistent, i.e. independent of the stationary phase and agreed within experimental error with the size parameters previously reported from saturated vapor pressure, latent heat of vaporization or density data.

  1. Separation of tocopherols by nano-liquid chromatography.

    Science.gov (United States)

    Fanali, Salvatore; Camera, Emanuela; Chankvetadze, Bezhan; D'Orazio, Giovanni; Quaglia, Maria Giovanna

    2004-04-16

    Nanoliquid chromatography (nano-LC) was used for the separation of tocopherols (delta-, gamma-, alpha-TOH), alpha-tocopherol acetate (alpha-TOH-Ac) and an antioxidant compound, namely butylated hydroxytoluene (BHT) used to prevent TOHs autoxidation. The separation was carried out in a fused silica capillary of 100 microm I.D. and 375 microm O.D. packed in our laboratory with RP18 silica stationary phase of either 5- or 3-microm diameter (23-cm long). The mobile phase was composed by mixtures of methanol (MeOH), acetonitrile (MeCN) and water. Typical analyses time for the separation of all the five components of the mixture were 6-9 min depending on the composition of the mobile phase. Efficiency and resolution were strongly influenced by the particle diameter and the highest Rs and N/m values were observed using 3-microm RP18 particles. Experiments performed with capillaries packed with 3-microm RP18 particles provided good limit of detection (LOD) and limit of quantification (LOQ) (for delta-, gamma-TOH, alpha-TOH-Ac were 4 and 8 microg/ml, while for alpha-TOH were 6 and 10 microg/ml, respectively). The optimized method was applied to extracts of serum and pharmaceutical preparation containing alpha-TOH and alpha-TOH-Ac.

  2. Quantitative analysis of multiple components based on liquid chromatography with mass spectrometry in full scan mode.

    Science.gov (United States)

    Xu, Min Li; Li, Bao Qiong; Wang, Xue; Chen, Jing; Zhai, Hong Lin

    2016-08-01

    Although liquid chromatography with mass spectrometry in full scan mode can obtain all the signals simultaneously in a large range and low cost, it is rarely used in quantitative analysis due to several problems such as chromatographic drifts and peak overlap. In this paper, we propose a Tchebichef moment method for the simultaneous quantitative analysis of three active compounds in Qingrejiedu oral liquid based on three-dimensional spectra in full scan mode of liquid chromatography with mass spectrometry. After the Tchebichef moments were calculated directly from the spectra, the quantitative linear models for three active compounds were established by stepwise regression. All the correlation coefficients were more than 0.9978. The limits of detection and limits of quantitation were less than 0.11 and 0.49 μg/mL, respectively. The intra- and interday precisions were less than 6.54 and 9.47%, while the recovery ranged from 102.56 to 112.15%. Owing to the advantages of multi-resolution and inherent invariance properties, Tchebichef moments could provide favorable results even in the situation of peaks shifting and overlapping, unknown interferences and noise signals, so it could be applied to the analysis of three-dimensional spectra in full scan mode of liquid chromatography with mass spectrometry.

  3. Development and evaluation of a liquid chromatography tandem mass spectrometry method for simultaneous determination of salivary melatonin, cortisol and testosterone

    DEFF Research Database (Denmark)

    Jensen, Marie Aarrebo; Hansen, Åse Marie; Abrahamsson, Peter

    2011-01-01

    saliva. We used liquid-liquid extraction (LLE) followed by liquid chromatography coupled to electrospray tandem mass spectrometry (LC-ESI-MS/MS) recorded in positive ion mode. Saliva samples were collected by spitting directly into tubes and 250 µL were used for analysis. The limits of detection were 4...

  4. Direct Measurement of Free Estradiol in Human Serum and Plasma by Equilibrium Dialysis-Liquid Chromatography-Tandem Mass Spectrometry.

    Science.gov (United States)

    Ray, Julie A; Kushnir, Mark M; Rockwood, Alan L; Meikle, A Wayne

    2016-01-01

    We describe a direct method of measurement of free estradiol using equilibrium dialysis followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Serum aliquots and internal standards are extracted by liquid-liquid extraction using methyl-tert-butyl ether (MTBE) followed by derivatization with dansyl chloride. An API 5500 mass spectrometer operated in positive electrospray mode is used for detection.

  5. Comparison of air-agitated liquid-liquid microextraction technique and conventional dispersive liquid-liquid micro-extraction for determination of triazole pesticides in aqueous samples by gas chromatography with flame ionization detection.

    Science.gov (United States)

    Farajzadeh, Mir Ali; Mogaddam, Mohammad Reza Afshar; Aghdam, Abdollah Abdollahi

    2013-07-26

    Two micro-extraction methods, air-agitated liquid-liquid microextraction (AALLME) and dispersive liquid-liquid microextraction (DLLME), have been compared with each other by applying them for the analysis of five triazole pesticides (penconazole, hexaconazole, diniconazole, tebuconazole and triticonazole) in aqueous samples by gas chromatography with flame ionization detection (GC-FID). In the AALLME method, which excludes any disperser solvent, much less volume of organic solvent is used. In order to form fine and dispersed organic droplets in the aqueous phase, the mixture of aqueous sample solution and extraction solvent is repeatedly aspirated and dispensed with a syringe. In the DLLME method, an appropriate mixture of extraction solvent and disperser solvent is rapidly injected by a syringe into the aqueous sample. Effect of the pertinent experimental factors on DLLME (i.e. identity and volume of the extraction and disperser solvents and ionic strength) and on AALLME (identity and volume of the extraction solvent, number of agitations, and ionic strength) were investigated. Under optimal conditions, limits of detection for the five target pesticides obtained by AALLME-GC-FID and DLLME-GC-FID ranged from 0.20 to 1.1ngmL(-1) and 1.9 to 5.9ngmL(-1), respectively. The relative standard deviations (RSDs, n=5) were in the range of 1-4% and 3-5% with the enrichment factors of 449-504 and 79-143 for AALLME-GC-FID and DLLME-GC-FID, respectively. Both of the compared methods are simple, fast, efficient, inexpensive and can be applied to the analysis of the five pesticides in different aqueous samples in which penconazole and hexaconazole were found. For spiked samples, the recoveries were in the ranges of 92-105%, and 92-104% for AALLME and DLLME, respectively.

  6. Determination of pyrazinamide in human by high performance liquid chromatography.

    Directory of Open Access Journals (Sweden)

    Revankar S

    1994-01-01

    Full Text Available A facile and sensitive high performance liquid chromatographic (HPLC technique has been developed for the determination pyrazinamide (PZA in human plasma. Nicotinamide(NIA is used as internal standard(IS. Plasma is deproteinized with 0.7 M perchloric acid; clear supernatant is neutralized with 1M NaOH and injected onto HPLC. The separation of pyrazinamide and the internal standard is carried out on a Supelco LC-18 (DB column with a basic mobile phase. Pyrazinoic acid, the major metabolite, other anti-tuberculous drugs and endogenous components do not interfere with measurement of pyrazinamide. The limit of detection of pyrazinamide with this method is 0.2 mg/0.2 ml plasma (CV 8.2%.

  7. [Determination of amygdalin in hawthorn by high performance liquid chromatography].

    Science.gov (United States)

    Lü, Weifeng; Ding, Mingyu

    2005-09-01

    A suitable method for extraction of amygdalin from hawthorn has been established. At first, the lipophilic components were removed with petroleum ether by ultrasonic extraction. The amygdalin was then extracted by methanol in a Soxhlet's apparatus. For quantitation, a high performance liquid chromatographic method was developed by using a reversed-phase C18 column, mobile phase of methanol-water (15:85, v/v) and a detection wavelengh of 215 nm. It can be concluded that the content of amygdalin is higher in the seeds than that in the hawthorn powder without the seeds and the yield of amygdalin is higher in the hawthorn pieces than that in the hawthorn powder.

  8. Determination of diflubenzuron and chlorbenzuron in fruits by combining acetonitrile-based extraction with dispersive liquid-liquid microextraction followed by high-performance liquid chromatography.

    Science.gov (United States)

    Ruan, Chunqiang; Zhao, Xiang; Liu, Chenglan

    2015-09-01

    In this study, a simple and low-organic-solvent-consuming method combining an acetonitrile-partitioning extraction procedure followed by "quick, easy, cheap, effective, rugged and safe" cleanup with ionic-liquid-based dispersive liquid-liquid microextraction and high-performance liquid chromatography with diode array detection was developed for the determination of diflubenzuron and chlorbenzuron in grapes and pears. Ionic-liquid-based dispersive liquid-liquid microextraction was performed using the ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate as the extractive solvent and acetonitrile extract as the dispersive solvent. The main factors influencing the efficiency of the dispersive liquid-liquid microextraction were evaluated, including the extractive solvent type and volume and the dispersive solvent volume. The validation parameters indicated the suitability of the method for routine analyses of benzoylurea insecticides in a large number of samples. The relative recoveries at three spiked levels ranged between 98.6 and 109.3% with relative standard deviations of less than 5.2%. The limit of detection was 0.005 mg/kg for the two insecticides. The proposed method was successfully used for the rapid determination of diflubenzuron and chlorbenzuron residues in real fruit samples.

  9. Monitoring of cefepime in human serum and plasma by micellar electrokinetic capillary chromatography: Improvement of sample preparation and validation by liquid chromatography coupled to mass spectrometry.

    Science.gov (United States)

    Šestáková, Nela; Theurillat, Regula; Sendi, Parham; Thormann, Wolfgang

    2017-02-20

    Cefepime monitoring in deproteinized human serum and plasma by micellar electrokinetic capillary chromatography and liquid chromatography coupled to mass spectrometry in presence of other drugs is reported. For micellar electrokinetic capillary chromatography, sample preparation comprised dodecylsulfate protein precipitation at pH 4.5 using an increased buffer concentration compared to that of a previous assay and removal of hydrophobic compounds with dichloromethane. This provided robust conditions for cefepime analysis in the presence of sulfamethoxazole and thus enabled its determination in samples of patients that receive co-trimoxazole. The liquid chromatography assay is based upon use of a column with a pentafluorophenyl-propyl modified and multi-endcapped stationary phase and the coupling to electrospray ionization with a single quadrupole detector. The performances of both assays with multi-level internal calibration were assessed with calibration and control samples and both assays were determined to be robust. Cefepime levels monitored by micellar electrokinetic capillary chromatography in samples from patients that were treated with cefepime only and with cefepime and co-trimoxazole were found to compare well with those obtained by liquid chromatography coupled to mass spectrometry. Cefepime drug levels determined by micellar electrokinetic capillary chromatography could thereby be validated. This article is protected by copyright. All rights reserved.

  10. Liquid chromatography with diode array detection combined with spectral deconvolution for the analysis of some diterpene esters in Arabica coffee brew.

    Science.gov (United States)

    Erny, Guillaume L; Moeenfard, Marzieh; Alves, Arminda

    2015-02-01

    In this manuscript, the separation of kahweol and cafestol esters from Arabica coffee brews was investigated using liquid chromatography with a diode array detector. When detected in conjunction, cafestol, and kahweol esters were eluted together, but, after optimization, the kahweol esters could be selectively detected by setting the wavelength at 290 nm to allow their quantification. Such an approach was not possible for the cafestol esters, and spectral deconvolution was used to obtain deconvoluted chromatograms. In each of those chromatograms, the four esters were baseline separated allowing for the quantification of the eight targeted compounds. Because kahweol esters could be quantified either using the chromatogram obtained by setting the wavelength at 290 nm or using the deconvoluted chromatogram, those compounds were used to compare the analytical performances. Slightly better limits of detection were obtained using the deconvoluted chromatogram. Identical concentrations were found in a real sample with both approaches. The peak areas in the deconvoluted chromatograms were repeatable (intraday repeatability of 0.8%, interday repeatability of 1.0%). This work demonstrates the accuracy of spectral deconvolution when using liquid chromatography to mathematically separate coeluting compounds using the full spectra recorded by a diode array detector.

  11. Determination of chloroacetanilide herbicide metabolites in water using high-performance liquid chromatography-diode array detection and high-performance liquid chromatography/mass spectrometry

    Science.gov (United States)

    Hostetler, K.A.; Thurman, E.M.

    2000-01-01

    Analytical methods using high-performance liquid chromatography-diode array detection (HPLC-DAD) and high-performance liquid chromatography/mass spectrometry (HPLC/MS) were developed for the analysis of the following chloroacetanilide herbicide metabolites in water: alachlor ethanesulfonic acid (ESA); alachlor oxanilic acid; acetochlor ESA; acetochlor oxanilic acid; metolachlor ESA; and metolachlor oxanilic acid. Good precision and accuracy were demonstrated for both the HPLC-DAD and HPLC/MS methods in reagent water, surface water, and ground water. The average HPLC-DAD recoveries of the chloroacetanilide herbicide metabolites from water samples spiked at 0.25, 0.5 and 2.0 ??g/l ranged from 84 to 112%, with relative standard deviations of 18% or less. The average HPLC/MS recoveries of the metabolites from water samples spiked at 0.05, 0.2 and 2.0 ??g/l ranged from 81 to 118%, with relative standard deviations of 20% or less. The limit of quantitation (LOQ) for all metabolites using the HPLC-DAD method was 0.20 ??g/l, whereas the LOQ using the HPLC/MS method was at 0.05 ??g/l. These metabolite-determination methods are valuable for acquiring information about water quality and the fate and transport of the parent chloroacetanilide herbicides in water. Copyright (C) 2000 Elsevier Science B.V.

  12. Chemical fingerprint of Ganmaoling granule by double-wavelength ultra high performance liquid chromatography and ultra high performance liquid chromatography with quadrupole time-of-flight mass spectrometry.

    Science.gov (United States)

    Lou, Qiong; Ye, Xiaolan; Zhou, Yingyi; Li, Hua; Song, Fenyun

    2015-06-01

    A method incorporating double-wavelength ultra high performance liquid chromatography with quadrupole time-of-flight mass spectrometry was developed for the investigation of the chemical fingerprint of Ganmaoling granule. The chromatographic separations were performed on an ACQUITY UPLC HSS C18 column (2.1 × 50 mm, 1.8 μm) at 30°C using gradient elution with water/formic acid (1%) and acetonitrile at a flow rate of 0.4 mL/min. A total of 11 chemical constituents of Ganmaoling granule were identified from their molecular weight, UV spectra, tandem mass spectrometry data, and retention behavior by comparing the results with those of the reference standards or literature. And 25 peaks were selected as the common peaks for fingerprint analysis to evaluate the similarities among 25 batches of Ganmaoling granule. The results of principal component analysis and orthogonal projection to latent structures discriminant analysis showed that the important chemical markers that could distinguish the different batches were revealed as 4,5-di-O-caffeoylquinic acid, 3,5-di-O-caffeoylquinic acid, and 4-O-caffeoylquinic acid. This is the first report of the ultra high performance liquid chromatography chemical fingerprint and component identification of Ganmaoling granule, which could lay a foundation for further studies of Ganmaoling granule.

  13. Analyses of Indole Compounds in Sugar Cane (Saccharum officinarum L. Juice by High Performance Liquid Chromatography and Liquid Chromatography-Mass Spectrometry after Solid-Phase Extraction

    Directory of Open Access Journals (Sweden)

    Jean Wan Hong Yong

    2017-03-01

    Full Text Available Simultaneous quantitative analysis of 10 indole compounds, including indole-3-acetic acid (IAA, one of the most important naturally occurring auxins and some of its metabolites, by high performance liquid chromatography (HPLC and liquid chromatography-mass spectrometry (LC-MS after solid-phase extraction (SPE was reported for the first time. The analysis was carried out using a reverse phase HPLC gradient elution, with an aqueous mobile phase (containing 0.1% formic acid modified by methanol. Furthermore, a novel SPE procedure was developed for the pre-concentration and purification of indole compounds using C18 SPE cartridges. The combination of SPE, HPLC, and LC-MS was applied to screen for the indole compounds present in sugar cane (Saccharum officinarum L. juice, a refreshing beverage with various health benefits. Finally, four indole compounds were successfully detected and quantified in sugar cane juice by HPLC, which were further unequivocally confirmed by LC-MS/MS experiments operating in the multiple reaction monitoring (MRM mode.

  14. Comparison of liquid-liquid extraction-thin layer chromatography with solid-phase extraction-high-performance thin layer chromatography in detection of urinary morphine.

    Science.gov (United States)

    Ahadi, Ali; Partoazar, Alireza; Abedi-Khorasgani, Mohammad-Hassan; Shetab-Boushehri, Seyed Vahid

    2011-09-01

    Liquid-liquid extraction-thin layer chromatography (LLE-TLC) has been a common and routine combined method for detection of drugs in biological materials. Solid-phase extraction (SPE) is gradually replacing the traditional LLE method. High performance thin layer chromatography (HPTLC) has several advantages over TLC. The present work studied the higher efficiency of a new SPE-HPTLC method over that of a routine LLE-TLC method, in extraction and detection of urinary morphine. Fifty-eight urine samples, primarily identified as morphine-positive samples by a strip test, were re-screened by LLE-TLC and SPE-HPTLC. The results of LLE-TLC and SPE-HPTLC were then compared with each other. The results showed that the SPE-HPTLC detected 74% of total samples as morphine-positive samples whereas the LLE-TLC detected 48% of the same samples. We further discussed the effect of codeine abuse on TLC analysis of urinary morphine. Regarding the importance of morphine detection in urine, the present combined SPE-HPTLC method is suggested as a replacement method for detection of urinary morphine by many reference laboratories.

  15. Evaluation of the Kinetic Performance Differences between Hydrophilic-Interaction Liquid Chromatography and Reversed-Phase Liquid Chromatography under Conditions of Identical Packing Structure.

    Science.gov (United States)

    Song, Huiying; Desmet, Gert; Cabooter, Deirdre

    2015-12-15

    A protocol using trifluoroacetic acid at a temperature of 60 °C is developed for the adequate removal of the stationary phase of reversed-phase liquid chromatography (RPLC) columns. This procedure allows for studying the same column first under RPLC and subsequently under hydrophilic-interaction liquid chromatography (HILIC) conditions to isolate intrinsic differences between mass transfer properties in HILIC and RPLC from differences in packing quality. The established procedure allows for a complete removal of the stationary phase (confirmed by retention studies and thermogravimetry analyses) while leaving the structure of the packing unaffected (witnessed by an unchanged external porosity and pressure drop). Accurate plate height analysis comparing compounds at the same zone retention factor indicates a significant difference in reduced c-term (typically 40-80% larger under HILIC conditions), despite the columns otherwise being identical. Correcting for the known contributions of longitudinal diffusion (b-term) and mass transfer (cm- and cs-term) to focus on band broadening originating from eddy dispersion, similar strong differences are observed (differences of some h = 0.3 up to 1.2). These findings show that the interior structure and retention mechanism of the particles have a very strong effect on the observed eddy dispersion, a factor typically ascribed to phenomena occurring outside the particles. This also implies that comparing the quality of packings of different particle types is virtually impossible without the availability of a sound model to correct for the intraparticle effect on the observed eddy dispersion.

  16. Dosage direct des alcools et éthers dans les carburants par chromatographie en phase liquide Direct Measurement of Alcohols and Ethers in Gasohols by Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Petroff N.

    2006-11-01

    Full Text Available Les différents composés oxygénés potentiels des carburants (alcools jusqu'aux butanols, acétone et éthers en C5 et C6 sont dosés par chromatographie en phase liquide inversée, avec deux qualités d'éluant sur la même colonne (RP 18. L'analyse est faite à 50 °C, avec un détecteur réfractométrique. La limite de sensibilité peut atteindre 100 ppm pour les alcools. The different potential oxygenated compounds in gasolines blended with alcohols up to butanols, acetone and ethers with 5 and 6 carbons are measured by reverse-phase liquid chromatography with two elution systems in the same column (RP 18. Analysis is performed at 50°C with a refractometer as detector. The sensitivity limit can reach 100 ppm for alcohols.

  17. Liquid chromatography-mass spectrometric and liquid chromatography-tandem mass spectrometric determination of hallucinogenic indoles psilocin and psilocybin in "magic mushroom" samples.

    Science.gov (United States)

    Kamata, Tooru; Nishikawa, Mayumi; Katagi, Munehiro; Tsuchihashi, Hitoshi

    2005-03-01

    Accurate and sensitive analytical methods for psilocin (PC) and psilocybin (PB), tryptamine-type hallucinogens contained in "magic mushrooms," were investigated using liquid chromatography-mass spectrometry (LC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS-MS). The chromatographic separation on an ODS column and mass spectral information gave complete discrimination between PC and PB without derivatization. The mass spectrometric detection had a high sensitivity, and the tandem mass spectrometric detection provided more specificity and accuracy, as well as high sensitivity. The detection limits ranged from 1 to 25 pg by LC-MS in the selected ion monitoring mode, and the intra- and inter-day coefficients of variation were estimated to be 4.21-5.93% by LC-MS-MS in the selected reaction monitoring mode. By applying the present LC-MS-MS technique to four real samples, the contents of PC and PB were found to vary over a wide range (0.60-1.4 and 0.18-3.8 mg/g dry wt. for PC and PB, respectively) between samples.

  18. On-line comprehensive two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography for preparative isolation of Peucedanum praeruptorum.

    Science.gov (United States)

    Wang, Xin-Yuan; Li, Jia-Fu; Jian, Ya-Mei; Wu, Zhen; Fang, Mei-Juan; Qiu, Ying-Kun

    2015-03-27

    A new on-line comprehensive preparative two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography (2D NPLC × RPLC) system was developed for the separation of complicated natural products. It was based on the use of a silica gel packed medium-pressure column as the first dimension and an ODS preparative HPLC column as the second dimension. The two dimensions were connected with normal-phase (NP) and reversed-phase (RP) enrichment units, involving a newly developed airflow assisted adsorption (AAA) technique. The instrument operation and the performance of this NPLC × RPLC separation method were illustrated by gram-scale isolation of ethanol extract from the roots of Peucedanum praeruptorum. In total, 19 compounds with high purity were obtained via automated multi-step preparative separation in a short period of time using this system, and their structures were comprehensively characterized by ESI-MS, (1)H NMR, and (13)C NMR. Including two new compounds, five isomers in two groups with identical HPLC and TLC retention values were also obtained and identified by 1D NMR and 2D NMR. This is the first report of an NPLC × RPLC system successfully applied in an on-line preparative process. This system not only solved the interfacing problem of mobile-phase immiscibility caused by NP and RP separation, it also exhibited apparent advantages in separation efficiency and sample treatment capacity compared with conventional methods.

  19. Determination of Niacinamide in Lotions and Creams Using Liquid-Liquid Extraction and High-Performance Liquid Chromatography

    Science.gov (United States)

    Usher, Karyn M.; Simmons, Carolyn R.; Keating, Daniel W.; Rossi, Henry F., III

    2015-01-01

    Chemical separations are an important part of an undergraduate chemistry curriculum. Sophomore students often get experience with liquid-liquid extraction in organic chemistry classes, but liquid-liquid extraction is not as often introduced as a quantitative sample preparation method in honors general chemistry or quantitative analysis classes.…

  20. Determination of Niacinamide in Lotions and Creams Using Liquid-Liquid Extraction and High-Performance Liquid Chromatography

    Science.gov (United States)

    Usher, Karyn M.; Simmons, Carolyn R.; Keating, Daniel W.; Rossi, Henry F., III

    2015-01-01

    Chemical separations are an important part of an undergraduate chemistry curriculum. Sophomore students often get experience with liquid-liquid extraction in organic chemistry classes, but liquid-liquid extraction is not as often introduced as a quantitative sample preparation method in honors general chemistry or quantitative analysis classes.…

  1. Purification of capsular polysaccharide from Neisseria meningitidis serogroup C by liquid chromatography.

    Science.gov (United States)

    Pato, Tânia Pinheiro; Barbosa, Antonio de Pádua R; da Silva Junior, José Godinho

    2006-03-07

    Neisseria meningitidis serogroup C capsular polysaccharide (MenCPS) is an important antigen against meningococcal infection. This paper describes a new purification methodology employing liquid chromatography that resulted in a polysaccharide showing the characteristics recommended by the World Health Organization for vaccine purposes. In this method, steps of the traditional procedure that yield low recovery and use toxic materials were modified. The present process consists in the following steps: (1) continuous flow centrifugation of the culture for removal of the cells; (2) supernatant concentration by tangential filtration (100 kDa cutoff); (3) addition of 0.5% DOC, heating to 55 degrees C during 30 min and tangential filtration (100 kDa cutoff); (4) anion exchange chromatography (Source 15Q) and (5) size exclusion chromatography (Sepharose CL-4B). The polysaccharide C fraction obtained in that way was dialyzed and freeze-dried. The structural identity of the polysaccharide was demonstrated by (1)H-NMR spectrometry.

  2. Analysis of acrylamide in cooked foods by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Rosén, Johan; Hellenäs, Karl-Erik

    2002-07-01

    A method using liquid chromatography tandem mass spectrometry (LC-MS-MS) with electrospray for the analysis of acrylamide in foods is reported. The method comprises the addition of deuterium-labelled acrylamide-d3, extraction with water, mixed mode solid phase extraction, ultrafiltration and a graphitised carbon column for chromatography. The transitions m/z 72 > 55, 72 > 54, 72 > 44, 72 > 27, 72 > 72 and 75 > 58 were recorded in multiple reaction monitoring mode for identification and quantification. In-house validation data for products from potatoes and cereals (30 to 10,000 microg kg(-1)) are presented (accuracy 91 to 102%, relative standard deviation 3 to 21%). Interlaboratory validation data (comparison with gas chromatography mass spectrometry, 25 to 2000 microg kg(-1)) showed excellent results (r2 = 0.998).

  3. High-throughput determination of cortisol, cortisone, and melatonin in oral fluid by on-line turbulent flow liquid chromatography interfaced with liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Fustinoni, Silvia; Polledri, Elisa; Mercadante, Rosa

    2013-07-15

    Cortisol, cortisone, and melatonin (CORTol, CORTone, and MELA, respectively) are hormones related to stress and sleep disorders. Their detection is relevant to epidemiological studies aimed at investigating the effects of circadian cycle disruption. The aim of this study was to develop and evaluate a high-throughput assay for the detection of CORTol, CORTone, and MELA concentrations in non-invasively collected oral fluid samples. A liquid chromatography/tandem mass spectrometry (LC/MS/MS) method to measure levels of CORTol, CORTone, and MELA in oral fluid samples in the presence of deuterated analogs was optimized and validated. A 50 μL aliquot of oral fluid sample, obtained by centrifugation of a chewed swab, was purified using on-line turbulent flow liquid chromatography. Analytes were then separated using C18 reversed-phase chromatography, subjected to positive ionization using an electrospray source, then quantitated using a triple quadrupole mass detector in the selected reaction monitoring mode. Limits of quantification and linear dynamic ranges were found to be 0.55 nmol/L, 5.5 nmol/L, and 0.004 nmol/L, and up to 28 nmol/L, 277 nmol/L, and 0.43 nmol/L for CORTol, CORTone, and MELA, respectively. Inter- and intra-run precisions as relative standard deviation values were <5%, and accuracies were within 95-106% of theoretical concentrations. An evaluation of matrix effects showed that the use of deuterated analogs controlled sources of bias. Furthermore, the total analysis time per sample was 13 min, resulting in a throughput of approximately 100 samples/day. To our knowledge, this is the first automated, high-throughput assay for the simultaneous quantification of CORTol, CORTone, and MELA in oral fluid specimens. Copyright © 2013 John Wiley & Sons, Ltd.

  4. Online coupling of hydrophilic interaction/strong cation exchange/reversed-phase liquid chromatography with porous graphitic carbon liquid chromatography for simultaneous proteomics and N-glycomics analysis.

    Science.gov (United States)

    Zhao, Yun; Law, Henry C H; Zhang, Zaijun; Lam, Herman C; Quan, Quan; Li, Guohui; Chu, Ivan K

    2015-10-09

    In this study we developed a fully automated three-dimensional (3D) liquid chromatography methodology-comprising hydrophilic interaction separation as the first dimension, strong cation exchange fractionation as the second dimension, and low-pH reversed-phase (RP) separation as the third dimension-in conjunction downstream with additional complementary porous graphitic carbon separation, to capture non-retained hydrophilic analytes, for both shotgun proteomics and N-glycomics analyses. The performance of the 3D system alone was benchmarked through the analysis of the total lysate of Saccharomyces cerevisiae, leading to improved hydrophilic peptide coverage, from which we identified 19% and 24% more proteins and peptides, respectively, relative to those identified from a two-dimensional hydrophilic interaction liquid chromatography and low-pH RP chromatography (HILIC-RP) system over the same mass spectrometric acquisition time; consequently, the 3D platform also provided enhanced proteome and protein coverage. When we applied the integrated technology to analyses of the total lysate of primary cerebellar granule neurons, we characterized a total of 2201 proteins and 16,937 unique peptides for this primary cell line, providing one of its most comprehensive datasets. Our new integrated technology also exhibited excellent performance in the first N-glycomics analysis of cynomolgus monkey plasma; we successfully identified 122 proposed N-glycans and 135 N-glycosylation sites from 122 N-glycoproteins, and confirmed the presence of 38 N-glycolylneuraminic acid-containing N-glycans, a rare occurrence in human plasma, through tandem mass spectrometry for the first time.

  5. Determination of acaricides in honey by high-performance liquid chromatography with photodiode array detection.

    Science.gov (United States)

    Martel, Anne-Claire; Zeggane, Sarah

    2002-04-19

    Rapid analytical methods are described to control quality of honeys, concerning residues of acaricides applied in hives to prevent Varroa jacobsoni infestation. A liquid-liquid extraction with hexane-propanol-2-ammonia (60 ml:30 ml:0.28%) was used for the simultaneous analysis of coumaphos, bromopropylate, amitraz and fluvalinate. For thymol, one clean up on a solid-phase extraction C18 (500 mg, 6 ml) column was performed; for rotenone, a liquid extraction with dichloromethane was realised. Quantitative recoveries obtained with honey were satisfactory and were superior to 80%. All acaricides are identified by reversed-phase high-performance liquid chromatography with photodiode array detection. Quantification limits obtained were below maximal residue limits when these exist.

  6. Gas chromatography on wall-coated open-tubular columns with ionic liquid stationary phases.

    Science.gov (United States)

    Poole, Colin F; Lenca, Nicole

    2014-08-29

    Ionic liquids have moved from novel to practical stationary phases for gas chromatography with an increasing portfolio of applications. Ionic liquids complement conventional stationary phases because of a combination of thermophysical and solvation properties that only exist for ionic solvents. Their high thermal stability and low vapor pressure makes them suitable as polar stationary phases for separations requiring high temperatures. Ionic liquids are good solvents and can be used to expand the chemical space for separations. They are the only stationary phases with significant hydrogen-bond acidity in common use; they extend the hydrogen-bond basicity of conventional stationary phases; they are as dipolar/polarizable as the most polar conventional stationary phases; and some ionic liquids are significantly less cohesive than conventional polar stationary phases. Problems in column coating techniques and related low column performance, column activity, and stationary phase reactivity require further exploration as the reasons for these features are poorly understood at present.

  7. Determination of Finasteride in Tablets by High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    K. Basavaiah

    2007-01-01

    Full Text Available A rapid, highly sensitive high performance liquid chromatographic method has been developed for the determination of finasteride(FNS in bulk drug and in tablets. FNS was eluted from a ODS C18 reversed phase column at laboratory temperature (30 ± 2°C with a mobile phase consisting of methanol and water (80+20 at a flow rate of 1 mL min-1 with UV detection at 225 nm. The retention time was ∼ 6.1 min and each analysis took not more than 10 min. Quantitation was achieved by measurement of peak area without using any internal standard. Calibration graph was linear from 2.0 to 30 μg mL-1 with limits of detection (LOD and quantification (LOQ being 0.2 and 0.6 μg mL-1, respectively. The method was validated according to the current ICH guidelines. Within-day co efficients of variation (CV ranged from 0.31 to 0.69% and between-day CV were in the range 1.2-3.2%. Recovery of FNS from the pharmaceutical dosage forms ranged from 97.89 – 102.9 with CV of 1.41-4.13%. The developed method was compared with the official method for FNS determination in its tablet forms.

  8. Analyses of acute kidney injury biomarkers by ultra-high performance liquid chromatography with mass spectrometry.

    Science.gov (United States)

    Al Za'abi, Mohammed; Ali, Badreldin H; ALOthman, Zeid A; Ali, Imran

    2016-01-01

    The newly developed acute kidney injury biomarkers are very important for the early and timely detection of kidney diseases. This review contains details of the analyses of several acute kidney injury biomarkers using ultra-high performance liquid chromatography-mass spectrometry in urine and plasma samples. In this review we attempt to discuss some aspects of the types of the biomarkers, patents, sample preparation, and the analyses. Besides, efforts were also made to discuss the possible uses of superficially porous (core-shell) columns in traditional and inexpensive high-performance liquid chromatography instruments. Additionally, the challenges and the future prospects are also highlighted. The present review will be useful for the academicians, scientists, and clinicians for the early detection of acute kidney injury biomarkers.

  9. Homochiral metal-organic framework used as a stationary phase for high-performance liquid chromatography.

    Science.gov (United States)

    Kong, Jiao; Zhang, Mei; Duan, Ai-Hong; Zhang, Jun-Hui; Yang, Rui; Yuan, Li-Ming

    2015-02-01

    Metal-organic frameworks are promising porous materials. Chiral metal-organic frameworks have attracted considerable attention in controlling enantioselectivity. In this study, a homochiral metal-organic framework [Co(2) (D-cam)(2) (TMDPy)] (D-cam = D-camphorates, TMDPy = 4,4'-trimethylenedipyridine) with a non-interpenetrating primitive cubic net has been used as a chiral stationary phase in high-performance liquid chromatography. It has allowed the successful separation of six positional isomers and six chiral compounds. The good selectivity and baseline separation, or at least 60% valley separation, confirmed its excellent molecular recognition characteristics. The relative standard deviations for the retention time of run-to-run and column-to-column were less than 1.8 and 3.1%, respectively. These results demonstrate that [Co(2) (D-cam)(2) (TMDPy)] may represent a promising chiral stationary phase for use in high-performance liquid chromatography.

  10. Analysis of antimycin A by reversed-phase liquid chromatography/nuclear magnetic-resonance spectrometry

    Science.gov (United States)

    Ha, Steven T.K.; Wilkins, Charles L.; Abidi, Sharon L.

    1989-01-01

    A mixture of closely related streptomyces fermentation products, antimycin A, Is separated, and the components are identified by using reversed-phase high-performance liquid chromatography with directly linked 400-MHz proton nuclear magnetic resonance detection. Analyses of mixtures of three amino acids, alanine, glycine, and valine, are used to determine optimal measurement conditions. Sensitivity increases of as much as a factor of 3 are achieved, at the expense of some loss in chromatographic resolution, by use of an 80-μL NMR cell, Instead of a smaller 14-μL cell. Analysis of the antimycin A mixture, using the optimal analytical high performance liquid chromatography/nuclear magnetic resonance conditions, reveals it to consist of at least 10 closely related components.

  11. Fractionation of Gibberellins in plant extracts by reverse phase high performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Jones, M.G.; Metzger, J.D.; Zeevaart, J.A.D.

    1980-02-01

    In studies on endogenous plant gibberellins (GAs), reverse phase (Bondapak C/sub 18/) high performance liquid chromatography (HPLC) has proved to be a useful method for the fractionation of plant extracts. The behavior of 18 authentic GAs in such a chromatographic system is described. The main factors determining chromatographic behavior are the degree and the position of hydroxylation of the GA. As an illustration of the use of reverse phase HPLC, the endogeneous GAs of immature seeds of Pharbitis nil L., strain Violet, were reinvestigated. The presence of gibberellins A/sub 3/, A/sub 5/, A/sub 17/, A/sub 20/, and A/sub 29/ was confirmed by gas-liquid chromatography-mass spectrometry. In addition, two other GAs, A/sub 19/ and A/sub 44/, were also identified in extracts of this material.

  12. Application of micellar liquid chromatography for the determination of antitumoral and antiretroviral drugs in plasma.

    Science.gov (United States)

    Peris-Vicente, Juan; Casas-Breva, Inmaculada; Roca-Genovés, Pasqual; Esteve-Romero, Josep

    2014-01-01

    In micellar liquid chromatography, the mobile phase is made of a surfactant and, eventually, an alcohol. This article describes several methods to measure the concentration of antitumoral and antiretroviral drugs in plasma, utilizing micellar liquid chromatography. Samples can be injected after dilution with a micellar solution and filtration, because proteins and other endogenous compounds are solubilized in micellar medium. We will discuss the following optimized parameters: dilution ratio, type of column, detection conditions and mobile phase composition. This article will also cover the validation performed following the International Conference on Harmonization guidelines and the results reported in the literature, indicating that the methods are useful for the routine analysis of plasma samples for clinical purposes.

  13. Identification of bupropion urinary metabolites by liquid chromatography/mass spectrometry.

    Science.gov (United States)

    Petsalo, Aleksanteri; Turpeinen, Miia; Tolonen, Ari

    2007-01-01

    Human urinary metabolism of the antidepressant bupropion was studied using liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS) and liquid chromatography/tandem mass spectrometry (LC/MS/MS). A total of 20 metabolites were detected and identified. The phase I metabolism included formation of morpholinohydroxybupropion, threo- and erythrohydrobupropion, aromatic hydroxylation, butyl group hydroxylation with ketone hydrogenation and dihydroxylation. These metabolites were detected either as the free form or as glucuronide and/or sulphate conjugates. In addition also m-chlorohippuric acid was detected. Of the phase I metabolites, a dihydroxylation to the aromatic ring and to the methyl group in the middle of the substrate molecule was reported here for the first time, as well as eight of the glucuronide conjugates (to hydroxy, dihydroxy, hydroxy and hydrogenation metabolites) and three of the sulphate conjugates (to aromatic hydroxy and hydroxy and hydrogenation metabolites). Copyright (c) 2007 John Wiley & Sons, Ltd.

  14. Atmospheric pressure chemical ionisation liquid chromatography/mass spectrometry of bacteriochlorophylls from Chlorobiaceae: characteristic fragmentations.

    Science.gov (United States)

    Airs, Ruth L; Keely, Brendan J

    2002-01-01

    Atmospheric pressure chemical ionisation liquid chromatography/mass spectrometry/mass spectrometry (APCI-LC/MS/MS) has been applied to the study of bacteriochlorophylls c, d, and e of phototrophic prokaryotes. Cultures of Chlorobiaceae containing bacteriochlorophyll c, d or e were examined using a high-resolution high-performance liquid chromatography (HPLC) method and APCI-LC/MS/MS employing post-column addition of formic acid. The results reveal complex distributions of bacteriochlorophyll homologues, with some closely eluting species giving isobaric protonated molecules. On-line LC/MS/MS studies reveal characteristic fragment ions for bacteriochlorophylls c, d, and e. Fragmentations involving loss of the extended alkyl substituents that are unique to bacteriochlorophylls c, d and e and their derivatives have been rationalised by studying the phaeophorbides and the results applied to the direct study of the bacteriochlorophylls.

  15. Use, history, and liquid chromatography/mass spectrometry chemical analysis of Aconitum

    Directory of Open Access Journals (Sweden)

    Mohamed El-Shazly

    2016-01-01

    Full Text Available Aconitum and its products have been used in Asia for centuries to treat various ailments, including arthritis, gout, cancer, and inflammation. In general, their preparations and dispensing have been restricted to qualified folk medicine healers due to their low safety index and reported toxicity. In the past few decades, official guidelines have been introduced in Asian pharmacopeias to control Aconitum herbal products. However, these guidelines were based on primitive analytical techniques for the determination of the whole Aconitum alkaloids and were unable to distinguish between toxic and nontoxic components. Recent advances in analytical techniques, especially high performance liquid chromatography (HPLC and electrophoresis coupled with highly sensitive detectors, allowed rapid and accurate determination of Aconitum secondary metabolites. Reports focusing on liquid chromatography/mass spectrometry analysis of Aconitum and its herbal products are discussed in the current review. This review can be used by the health regulatory authorities for updating pharmacopeial guidelines of Aconitum and its herbal products.

  16. Arsenic speciation by liquid chromatography coupled with ionspray tandem mass spectrometry

    DEFF Research Database (Denmark)

    Corr, J. J.; Larsen, Erik Huusfeldt

    1996-01-01

    fragmentation patterns showing molecular dissociation through an expected common product ion were obtained for the four arsenosugars, Molecular mode detection was utilized for qualitative verification of speciation analysis by high-performance liquid chromatography coupled to inductively coupled plasma mass......Ionspray mass spectrometry, a well established organic analysis technique, has been coupled to high-performance liquid chromatography for speciation of organic arsenic compounds, The ionspray source and differentially pumped interface of the mass spectrometer were operated in dual modes...... for elemental and molecular analysis, Tandem mass spectrometry was employed to increase selectivity, Dual mode detection was applied to demonstrate the utility of the technique for analysis of nine organoarsenic standards, including four dimethylarsinylriboside derivatives (arsenosugars), Structural...

  17. Current practice of liquid chromatography-mass spectrometry in metabolomics and metabonomics.

    Science.gov (United States)

    Gika, Helen G; Theodoridis, Georgios A; Plumb, Robert S; Wilson, Ian D

    2014-01-01

    Based on publication and citation numbers liquid chromatography (LC-MS) has become the major analytical technology in the field of global metabolite profiling. This dominance reflects significant investments from both the research community and instrument manufacturers. Here an overview of the approaches taken for LC-MS-based metabolomics research is given, describing critical steps in the realisation of such studies: study design and its needs, specific technological problems to be addressed and major obstacles in data treatment and biomarker identification. The current state of the art for LC-MS-based analysis in metabonomics/metabolomics is described including recent developments in liquid chromatography, mass spectrometry and data treatment as these are applied in metabolomics underlining the challenges, limitations and prospects for metabolomics research. Examples of the application of metabolite profiling in the life sciences focusing on disease biomarker discovery are highlighted. In addition, new developments and future prospects are described. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Liquid chromatography-thermospray mass spectrometry of DNA adducts formed with mitomycin C, porfiromycin and thiotepa.

    Science.gov (United States)

    Musser, S M; Pan, S S; Callery, P S

    1989-07-14

    High-performance liquid chromatography (HPLC) and thermospray mass spectrometry were combined for the analysis of DNA adducts formed from the interaction of the anticancer drugs mitomycin C, porfiromycin and thiotepa with calf thymus DNA. The adducts formed from reaction of mitomycin C and porfiromycin with DNA were separated from unmodified nucleosides by HPLC on a C18 column and identified by thermospray mass spectrometry. Thiotepa DNA adducts readily depurinated from DNA and were chromatographed and identified by thermospray liquid chromatography-mass spectrometry as the modified bases without the ribose moiety attached. The utility of thermospray mass spectrometry for the identification of microgram quantities of nucleoside adducts and depurinated base adducts of these anticancer drugs was demonstrated.

  19. 现代液相色谱进展%Progress of Modern Liquid Chromatography

    Institute of Scientific and Technical Information of China (English)

    韩南银; 王利生; 傅若农

    1999-01-01

      本文在查阅大量文献的基础上从液相色谱的发展史、固定相、流动相以及检测器四个方面综述了液相色谱的进展,对了解液相色谱的新进展有着重要参考价值。%  The paper dealed with the progress of developing history, stationary phases, fluid phases and detectors of liquid chromatography. It has important reference values for chemists to learn the new progress of modern liquid chromatography in the field of chemistry.

  20. Serum Protein Profile Study of Clinical Samples Using High Performance Liquid Chromatography-Laser Induced Fluorescence

    DEFF Research Database (Denmark)

    Karemore, Gopal Raghunath; Ukendt, Sujatha; Rai, Lavanya

    2009-01-01

    The serum protein profiles of normal subjects, patients diagnosed with cervical cancer, and oral cancer were recorded using High Performance Liquid Chromatography combined with Laser Induced Fluorescence detection (HPLC-LIF). Serum protein profiles of the above three classes were tested for estab......The serum protein profiles of normal subjects, patients diagnosed with cervical cancer, and oral cancer were recorded using High Performance Liquid Chromatography combined with Laser Induced Fluorescence detection (HPLC-LIF). Serum protein profiles of the above three classes were tested...... for establishing the ability of HPLC-LIF protein profiling technique for discrimination, using hard clustering and Fuzzy clustering methods. The clustering algorithms have quite successfully classified the profiles as belonging to normal, cancer of cervix, and oral cancer conditions....

  1. High-pressure liquid chromatography with direct injection of gas sample.

    Science.gov (United States)

    Astanin, Anton I; Baram, Grigory I

    2017-06-09

    The conventional method of using liquid chromatography to determine the composition of a gaseous mixture entails dissolving vapors in a suitable solvent, then obtaining a chromatograph of the resulting solution. We studied the direct introduction of a gaseous sample into a C18 reversed-phase column, followed by separation of the components by HPLC with UV detection. Since the chromatography was performed at high pressure, vapors readily dissolved in the eluent and the substances separated in the column as effectively as in liquid samples. Samples were injected into the column in two ways: a) through the valve without a flow stop; b) after stopping the flow and relieving all pressure. We showed that an injectable gas volume could reach 70% of column dead volume. When an injected gaseous sample volume was less than 10% of the column dead volume, the resulting peaks were symmetrical and the column efficiency was high. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Alternative solvents for improving the greenness of normal phase liquid chromatography of lipid classes.

    Science.gov (United States)

    Prache, Nolwenn; Abreu, Sonia; Sassiat, Patrick; Thiébaut, Didier; Chaminade, Pierre

    2016-09-16

    An evaluation of solvents alternative to n-heptane (d-limonene and hexamethyldisiloxane) and chloroform (cyclopentyl methyl ether, 2-methyltetrahydrofuran and isopentyl acetate) was developed for lipid classes separation of non-polar cholesteryl ester to highly polar phospholipids by high-performance liquid chromatography on bare silica stationary phase and evaporative light-scattering detection. Screening of alternative solvents was used to estimate their compatibility with liquid chromatography and evaporative light-scattering detection and to evaluate their chromatographic selectivity. This work shows that n-heptane can be advantageously replaced by hexamethyldisiloxane. An increase of non-polar lipids retention is observed with hexamethyldisiloxane as weak solvent. Chloroform, which is largely used for lipid analysis, might be replaced efficaciously by cyclopentyl methyl ether, 2-methyltetrahydrofuran or isopentyl acetate. Aside from offering a different selectivity, the gradients composed by one or both alternative solvents gave efficient and comparable or even better separations than those obtained with conventional solvents.

  3. Ultrasound-assisted dispersive liquid-liquid microextraction combined with high-performance liquid chromatography-fluorescence detection for sensitive determination of biogenic amines in rice wine samples.

    Science.gov (United States)

    Huang, Ke-Jing; Wei, Cai-Yun; Liu, Wei-Li; Xie, Wan-Zhen; Zhang, Jun-Feng; Wang, Wei

    2009-09-18

    Ultrasound-assisted dispersive liquid-liquid microextraction coupled with high-performance liquid chromatography-fluorescence detection was used for the extraction and determination of three biogenic amines including octopamine, tyramine and phenethylamine in rice wine samples. Fluorescence probe 2,6-dimethyl-4-quinolinecarboxylic acid N-hydroxysuccinimide ester was applied for derivatization of biogenic amines. Acetonitrile and 1-octanol were used as disperser solvent and extraction solvent, respectively. Extraction conditions including the type of extraction solvent, the volume of extraction solvent, ultrasonication time and centrifuging time were optimized. After extraction and centrifuging, analyte was injected rapidly into high-performance liquid chromatography and then detected with fluorescence. The calibration graph of the proposed method was linear in the range of 5-500 microg mL(-1) (octopamine and tyramine) and 0.025-2.5 microg mL(-1) (phenethylamine). The relative standard deviations were 2.4-3.2% (n=6) and the limits of detection were in the range of 0.02-5 ng mL(-1). The method was applied to analyze the rice wine samples and spiked recoveries in the range of 95.42-104.56% were obtained. The results showed that ultrasound-assisted dispersive liquid-liquid microextraction was a very simple, rapid, sensitive and efficient analytical method for the determination of trace amount of biogenic amines.

  4. Rhamnolipid biosurfactant analysis using online turbulent flow chromatography-liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Behrens, Beate; Helmer, Patrick O; Tiso, Till; Blank, Lars M; Hayen, Heiko

    2016-09-23

    Rhamnolipids are biosurfactants produced by a variety of bacterial species that present a promising alternative to surfactants from petrochemical or oleochemical origin. The success of the fermentation is evaluated by subsequent qualitative and quantitative analysis. However, the sample preparation for high numbers of samples is often laborious and inefficient. In this study an online sample preparation is developed for the qualitative and quantitative analysis of rhamnolipids by LC-MS/MS. Online sample preparation is carried out on a TurboFlow Cyclone MAX column using turbulent flow chromatography. Sample preparation prior the analysis is minimized to a dilution and syringe filtration step leading to an instrumental analysis time of 33min. The limit of detection and the limit of quantification were 0.4ng and 0.6ng on column, respectively. Recovery of the main mono- and di-rhamnolipids from a fermentation sample was 102-104%. Additionally, the rhamnolipid biosynthetic precursors 3-hydroxy(alkanoyloxy)alkanoic acids (HAAs) are covered, albeit extraction is not quantitative (85-90%). The analysis of rhamnolipids from four different microbial species was in good agreement with previous reports. The presented method allows rapid and comprehensive analysis of rhamnolipids with minimal sample preparation directly from the fermentation broth. The application of complementary data-dependent MS/MS acquisition enables non-target screening of rhamnolipids.

  5. Ionic liquids for improving the extraction of NSAIDs in water samples using dispersive liquid-liquid microextraction by high performance liquid chromatography-diode array-fluorescence detection.

    Science.gov (United States)

    Toledo-Neira, Carla; Álvarez-Lueje, Alejandro

    2015-03-01

    A rapid, sensitive and efficient analytical method based on the use of ionic liquids for determination of non-steroidal anti-inflammatory drugs (NSAIDs) in water samples was developed. High-performance liquid chromatography equipped with a diode array and fluorescence detector was used for quantification of ketoprofen, ibuprofen and diclofenac in tap and river water samples. This new method relies on the use of two ionic liquids with multiple functionalities: one functions as an extraction solvent (1-butyl-3-methylimidazolium hexafluorophosphate ([BMIM][PF6]), and the other changes the polarity in the aqueous medium (1-butyl-3-methylimidazolium tetrafluoroborate, ([BMIM][BF4]). Factors such as the type and volume of the ILs and dispersive solvent, sample volume, and centrifugation time were investigated and optimized. The optimized method exhibited good precision, with relative standard deviation values between 2% and 3%, for the three NSAIDs. Limits of detection achieved for all of the analytes were between 17 and 95 ng mL(-1), and the recoveries ranged from 89% to 103%. Furthermore, the enrichment factors ranged from 49 to 57. The proposed method was successfully applied to the analysis of NSAIDs in tap and river water samples.

  6. Simultaneous quantification of five major active components in capsules of the traditional Chinese medicine 'Shu-Jin-Zhi-Tong' by high performance liquid chromatography

    Institute of Scientific and Technical Information of China (English)

    Xing-Xin Yang; Xiao-Xia Zhang; Rui-Miao Chang; Yan.Wei Wang; Xiao-Ni Li

    2011-01-01

    A simple and reliable high performance liquid chromatography (HPLC) method has been developed for the simultaneous quantification of five major bioactive components in 'Shu-Jin- Zhi-Tong' capsules (SJZTC), for the purposes of quality control of this commonly prescribed traditional Chinese medicine. Under the optimum conditions, excellent separation was achieved, and the assay was fully validated in terms of linearity, precision, repeatability, stability and accuracy. The validated method was applied successfully to the determination of the five compounds in SJZTC samples from different production batches. The HPLC method can be used as a valid analytical method to evaluate the intrinsic quality of SJZTC.

  7. Determination of preservatives in cosmetics, cleaning agents and pharmaceuticals using fast liquid chromatography.

    Science.gov (United States)

    Baranowska, Irena; Wojciechowska, Iwona; Solarz, Natalia; Krutysza, Ewa

    2014-01-01

    This paper reports the development of a method for simultaneously determining five preservatives in cosmetics, cleaning agents and pharmaceuticals by fast liquid chromatography. Methylisothiazolinone, methylchloroisothiazolinone, benzyl alcohol, sodium benzoate and methylparaben were separated on a Chromolith Fast Gradient reversed-phase 18e column using gradient elution with acetonitrile and a 0.1% aqueous solution of formic acid, with a run time of 3 min. The preparation of solid and liquid samples included ultrasonic extraction with methanol with recoveries ranging from 69 to 119%. The developed method was used to analyze samples of cosmetics (66 samples), cleaning agents (five samples) and pharmaceutical industry products (17 samples).

  8. Qualitative and Quantitative Analysis of Major Triterpenoids in Alismatis Rhizoma by High Performance Liquid Chromatography/Diode-Array Detector/Quadrupole-Time-of-Flight Mass Spectrometry and Ultra-Performance Liquid Chromatography/Triple Quadrupole Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Wanli Zhao

    2015-07-01

    Full Text Available Alismatis Rhizoma (AMR is a well-known natural medicine with a long history in Chinese medicine and has been commonly used for treating a wide range of ailments related to dysuria, edema, nephropathy, hyperlipidaemia, diabetes, inflammation as well as tumors in clinical applications. Most beneficial effects of AMR are attributed to the presence of protostane terpenoids, the major active ingredients of Alismatis Rhizoma (AMR. In this study, a systematic high performance liquid chromatography/diode-array detector/quadrupole-time-of-flight mass spectrometry (HPLC-DAD-Q-TOF MS and ultra-performance liquid chromatography/triple quadrupole mass spectrometry (UPLC-QqQ MS method was developed for qualitative and quantitative analyses of the major AMR triterpenoids. First, a total of 25 triterpenoid components, including 24 known compounds and one new compound were identified by comparison with UV spectra, molecular ions and fragmentation behaviors of reference standards or the literature. Second, an efficient method was established for the rapid simultaneous determination of 14 representative triterpenoids by UPLC-QqQ MS. Forty-three batches of AMR were analyzed with linearity (r, 0.9980–0.9999, intra-day precision (RSD, 1.18%–3.79%, inter-day precision (RSD, 1.53%–3.96%, stability (RSD, 1.32%–3.97%, repeatability (RSD, 2.21%–4.25%, and recovery (98.11%–103.8%. These results indicated that new approaches combining HPLC-DAD-Q-TOF MS and UPLC-QqQ MS are applicable in the qualitative and quantitative analysis of AMR.

  9. Differentiation of mint (Mentha haplocalyx Briq.) from different regions in China using gas and liquid chromatography.

    Science.gov (United States)

    Dong, Wenjiang; Ni, Yongnian; Kokot, Serge

    2015-02-01

    In this study, complex substances such as Mint (Mentha haplocalyx Briq.) samples from different growing regions in China were analyzed for phenolic compounds by high-performance liquid chromatography with diode array detection and for the volatile aroma compounds by gas chromatography with mass spectrometry. Chemometrics methods, e.g. principal component analysis, back-propagation artificial neural networks, and partial least squares discriminant analysis, were applied to resolve complex chromatographic profiles of Mint samples. A total of 49 aroma components and 23 phenolic compounds were identified in 79 Mint samples. Principal component analysis score plots from gas chromatography with mass spectrometry and high-performance liquid chromatography with diode array detection data sets showed a clear distinction among Mint from three different regions in China. Classification results showed that satisfactory performance of prediction ability for back-propagation artificial neural networks and partial least squares discriminant analysis. The major compounds that contributed to the discrimination were chlorogenic acid, unknown 3, kaempherol 7-O-rutinoside, salvianolic acid L, hesperidin, diosmetin, unknown 6 and pebrellin in Mint according to regression coefficients of the partial least squares discriminant analysis model. This study indicated that the proposed strategy could provide a simple and rapid technique to distinguish clearly complex profiles from samples such as Mint.

  10. A simple, rapid and validated high-performance liquid chromatography method suitable for clinical measurements of human mercaptalbumin and non-mercaptalbumin.

    Science.gov (United States)

    Yasukawa, Keiko; Shimosawa, Tatsuo; Okubo, Shigeo; Yatomi, Yutaka

    2017-01-01

    Background Human mercaptalbumin and human non-mercaptalbumin have been reported as markers for various pathological conditions, such as kidney and liver diseases. These markers play important roles in redox regulations throughout the body. Despite the recognition of these markers in various pathophysiologic conditions, the measurements of human mercaptalbumin and non-mercaptalbumin have not been popular because of the technical complexity and long measurement time of conventional methods. Methods Based on previous reports, we explored the optimal analytical conditions for a high-performance liquid chromatography method using an anion-exchange column packed with a hydrophilic polyvinyl alcohol gel. The method was then validated using performance tests as well as measurements of various patients' serum samples. Results We successfully established a reliable high-performance liquid chromatography method with an analytical time of only 12 min per test. The repeatability (within-day variability) and reproducibility (day-to-day variability) were 0.30% and 0.27% (CV), respectively. A very good correlation was obtained with the results of the conventional method. Conclusions A practical method for the clinical measurement of human mercaptalbumin and non-mercaptalbumin was established. This high-performance liquid chromatography method is expected to be a powerful tool enabling the expansion of clinical usefulness and ensuring the elucidation of the roles of albumin in redox reactions throughout the human body.

  11. Vortex-assisted hollow fibre liquid-phase microextraction technique combined with high performance liquid chromatography-diode array detection for the determination of oestrogens in milk samples.

    Science.gov (United States)

    Wang, Peijin; Xiao, Yu; Liu, Wenjun; Wang, Juan; Yang, Yaling

    2015-04-01

    A rapid, simple, sensitive and environmentally friendly method has been developed for the determination of three oestrogens (17β-estradiol (17β-E2), estrone (E1), and diethylstilbestrol (DES)) in milk samples by using vortex-assisted hollow fibre liquid-phase microextraction (VA-HF-LPME) and high performance liquid chromatography. Method is based on the microextraction of oestrogens from sample solution into 15 μL of nonanoic acid as extracting agent, which is placed inside the hollow fibre followed by vortex-mixing. Vortex provided effective and mild mixing of sample solution and increased the contact between analytes and boundary layers of the hollow fibre, thereby enhancing mass transfer rate and leading to high recovery of target analytes. The extraction equilibrium is achieved within 2 min. Parameters influencing the recovery were investigated and optimized. The proposed technique provided good linearity (>0.9984), repeatability (RSD = 2.56-4.38), low limits of detection (0.06-0.17 ng mL(-1)), and high enrichment factor (330).

  12. Determination of cyclic and linear siloxanes in wastewater samples by ultrasound-assisted dispersive liquid-liquid microextraction followed by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Cortada, Carol; dos Reis, Luciana Costa; Vidal, Lorena; Llorca, Julio; Canals, Antonio

    2014-03-01

    A fast, simple and environmentally friendly ultrasound-assisted dispersive liquid-liquid microextraction (USA-DLLME) procedure has been developed to preconcentrate eight cyclic and linear siloxanes from wastewater samples prior to quantification by gas chromatography-mass spectrometry (GC-MS). A two-stage multivariate optimization approach has been developed employing a Plackett-Burman design for screening and selecting the significant factors involved in the USA-DLLME procedure, which was later optimized by means of a circumscribed central composite design. The optimum conditions were: extractant solvent volume, 13 µL; solvent type, chlorobenzene; sample volume, 13 mL; centrifugation speed, 2300 rpm; centrifugation time, 5 min; and sonication time, 2 min. Under the optimized experimental conditions the method gave levels of repeatability with coefficients of variation between 10 and 24% (n=7). Limits of detection were between 0.002 and 1.4 µg L(-1). Calculated calibration curves gave high levels of linearity with correlation coefficient values between 0.991 and 0.9997. Finally, the proposed method was applied for the analysis of wastewater samples. Relative recovery values ranged between 71 and 116% showing that the matrix had a negligible effect upon extraction. To our knowledge, this is the first time that combines LLME and GC-MS for the analysis of methylsiloxanes in wastewater samples.

  13. Sensitive Detection of Organophosphorus Pesticides in Medicinal Plants Using Ultrasound-Assisted Dispersive Liquid-Liquid Microextraction Combined with Sweeping Micellar Electrokinetic Chromatography.

    Science.gov (United States)

    Wei, Jin-Chao; Hu, Ji; Cao, Ji-Liang; Wan, Jian-Bo; He, Cheng-Wei; Hu, Yuan-Jia; Hu, Hao; Li, Peng

    2016-02-03

    A simple, rapid, and sensitive method using ultrasound-assisted dispersive liquid-liquid microextraction (UA-DLLME) combined with sweeping micellar electrokinetic chromatography (sweeping-MEKC) has been developed for the determination of nine organophosphorus pesticides (chlorfenvinphos, parathion, quinalphos, fenitrothion, azinphos-ethyl, parathion-methyl, fensulfothion, methidathion, and paraoxon). The important parameters that affect the UA-DLLME and sweeping efficiency were investigated. Under the optimized conditions, the proposed method provided 779.0-6203.5-fold enrichment of the nine pesticides compared to the normal MEKC method. The limits of detection ranged from 0.002 to 0.008 mg kg(-1). The relative standard deviations of the peak area ranged from 1.2 to 6.5%, indicating the good repeatability of the method. Finally, the developed UA-DLLME-sweeping-MEKC method has been successfully applied to the analysis of the investigated pesticides in several medicinal plants, including Lycium chinense, Dioscorea opposite, Codonopsis pilosula, and Panax ginseng, indicating that this method is suitable for the determination of trace pesticide residues in real samples with complex matrices.

  14. Application of hollow fibre liquid phase microextraction for the multiresidue determination of pesticides in alcoholic beverages by ultra-high pressure liquid chromatography coupled to tandem mass spectrometry.

    Science.gov (United States)

    Bolaños, P Plaza; Romero-González, R; Frenich, A Garrido; Vidal, J L Martínez

    2008-10-24

    An alternative method has been developed to determine more than 50 pesticides in alcoholic beverages using hollow fibre liquid phase microextraction (HF-LPME) followed by ultra-high pressure liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS), without any further clean-up step. Pesticides were extracted from the sample to the organic solvent immobilized in the fibre and they were desorbed in methanol prior to chromatographic analysis. Experimental parameters related to microextraction such as type of organic solvent, extraction time and agitation rate have been optimized. The extraction method has been validated for several types of alcoholic beverages such as wine and beer, and no matrix effect was observed. The technique requires minimal sample handling and solvent consumption. Using optimum conditions, low detection limits (0.01-5.61microgL(-1)) and good linearity (R(2)>0.95) were obtained. Repeatability and interday precision ranged from 3.0 to 16.8% and from 5.9 to 21.2%, respectively. Finally the optimized method was applied to real samples and carbaryl, triadimenol, spyroxamine, epoxiconazole, triflumizol and fenazaquin were detected in some of the analyzed samples. The obtained results indicated that the new method can be successfully applied for extraction and determination of pesticides in alcoholic beverages, increasing sample throughput.

  15. Analysis of endocrine disruptor compounds in marine sediments by in cell clean up-pressurized liquid extraction-liquid chromatography tandem mass spectrometry determination.

    Science.gov (United States)

    Salgueiro-González, N; Turnes-Carou, I; Muniategui-Lorenzo, S; López-Mahía, P; Prada-Rodríguez, D

    2014-12-10

    A less time-, solvent- and sorbent-consuming analytical methodology for the determination of bisphenol A and alkylphenols (4-tert-octylphenol, 4-octylphenol, 4-n-nonylphenol, nonylphenol) in marine sediment was developed and validated. The method was based on selective pressurized liquid extraction (SPLE) with a simultaneous in cell clean up combined with liquid chromatography-electrospray ionization tandem mass spectrometry in negative mode (LC-ESI-MS/MS). The SPLE extraction conditions were optimized by a Plackett-Burman design followed by a central composite design. Quantitation was performed by standard addition curves in order to correct matrix effects. The analytical features of the method were satisfactory: relative recoveries varied between 94 and 100% and repeatability and intermediate precision were <6% for all compounds. Uncertainty assessment of measurement was estimated on the basis of an in-house validation according to EURACHEM/CITAC guide. Quantitation limits of the method (MQL) ranged between 0.17 (4-n-nonylphenol) and 4.01 ng g(-1) dry weight (nonylphenol). Sensitivity, selectivity, automaticity and fastness are the main advantages of this green methodology. As an application, marine sediment samples from Galicia coast (NW of Spain) were analysed. Nonylphenol and 4-tert-octylphenol were measured in all samples at concentrations between 20.1 and 1409 ng g(-1) dry weight, respectively. Sediment toxicity was estimated and no risk to aquatic biota was found.

  16. Resolution of the stereoisomers of baclofen by high performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Weatherby, R.P.; Allan, R.D.; Johnston, G.A.R. (Sydney Univ. (Australia))

    1984-01-01

    The GABA analogue baclofen (3-(p-chlorophenyl)-4-aminobutanoic acid) has stereospecific actions on the peripheral and central nervous systems. This paper describes the resolution of tritium-labelled baclofen by high performance liquid chromatography on a reverse-phase C18 column using a chiral mobile phase. The method, which may have general application to certain other GABA analogues, affords optically pure (+)- and (-)-baclofen labelled with tritium to high specific activity suitable for ligand binding and other neurochemical studies.

  17. A simple high performance liquid chromatography method for determination of rebamipide in rat urine

    OpenAIRE

    Cooper, Dustin L.; Harirforoosh, Sam

    2014-01-01

    Rebamipide is a mucoprotective agent commonly used to prevent nonsteriodal anti-inflammatory drug-induced gastrointenstinal side effects [1]. Human plasma and urine analysis of rebamipide utilizing high performance liquid chromatography (HPLC) have been reported [2]. Recently, we reported on the plasma levels of rebamipide in presense or absence of celecoxib or diclofenac in rats [3] using a modified HPLC method of detection developed by Jeoung et al. [4]. To tailor the method towards use in ...

  18. Profiling and Quantitation of Bacterial Carotenoids by Liquid Chromatography and Photodiode Array Detection

    OpenAIRE

    1989-01-01

    An analytical method for the profiling and quantitative determination of carotenoids in bacteria is described. Exhaustive extraction of the pigments from four selected bacterial strains required treatment of the cells with potassium hydroxide or liquefied phenol or both before the addition of the extracting solvent (methanol or diethyl ether). The carotenoids in the extracts were separated by nonaqueous reversed-phase liquid chromatography in conjunction with photodiode array absorption detec...

  19. Quality Evaluation of Potentilla fruticosa L. by High Performance Liquid Chromatography Fingerprinting Associated with Chemometric Methods

    OpenAIRE

    Wei Liu; Dongmei Wang; Jianjun Liu; Dengwu Li; Dongxue Yin

    2016-01-01

    The present study was performed to assess the quality of Potentilla fruticosa L. sampled from distinct regions of China using high performance liquid chromatography (HPLC) fingerprinting coupled with a suite of chemometric methods. For this quantitative analysis, the main active phytochemical compositions and the antioxidant activity in P. fruticosa were also investigated. Considering the high percentages and antioxidant activities of phytochemicals, P. fruticosa samples from Kangding, Sichua...

  20. Determination of urinary metanephrine, normetanephrine and methoxymetanephrine by liquid chromatography-electrospray tandem mass spectrometry.

    OpenAIRE

    Le Goff, Caroline; Peeters, Stéphanie; NETCHACOVITCH, Matthieu; Kaux, Jean-François; CRINE, Yannick; Cavalier, Etienne

    2013-01-01

    Background: The aim of this work was to develop and validate a method for the determination of metanephrine (M), normetanephrine (NM) and methoxymetanephrine (METHO) in urine by liquid chromatography-tandem mass spectrometry (LCMS-MS) on the Triple Quad TQ 5500 from AB SCIEX. In fact, the determination of M and NM concentrations is used in clinical diagnosis of pheochromocytoma, a rare but potentially fatal tumor arising primarily from the chromaffin cells of the adrenal medulla. Meth...

  1. [Comparison of refractometric and ultraviolet detection methods in lactulose assay by high performance liquid chromatography].

    Science.gov (United States)

    Vaccher, C; Berthelot, P; Flouquet, N; Debaert, M

    1990-01-01

    Dosage of lactulose and determination of related sugars (lactose, fructose, galactose, épilactose) were undertaken by high performance liquid chromatography (HPLC). The present note described two modes of detection used simultaneously and compared: refractive index detector (RI) and multiwavelength ultraviolet detector (UV). HPLC is performed with an aminopropylsylil phase as stationary phase and an isocratic mobile phase containing acetonitrile and aqueous sodium phosphate. The results are outlined and discussed.

  2. Differentiation of coloured inks of inkjet printer cartridges by thin layer chromatography and high performance liquid chromatography.

    Science.gov (United States)

    Poon, N L; Ho, S S H; Li, C K

    2005-01-01

    Document examiners are frequently asked to determine whether or not a colour printout has originated from a particular inkjet printer. The printer can rarely be identified unless some unique defects or irregularities of the printer are present on the printout. However, it is possible to decipher the make and/or model of the printer by comparing the ink-profile of the questioned printout with that of a seized inkjet printer cartridge or from one in a database. This paper presents an overview of a systematic approach to characterising and discriminating the inks of different inkjet printer cartridges using thin layer chromatography (TLC) and high pressure liquid chromatography (HPLC) with multi-wavelength ultra-violet/visible (UV/Vis) detection. Ink samples from 23 different inkjet printer cartridges (including originals and substitutes) of different brands and colour printouts, printed by known printers were examined with newly developed chromatographic methods. Subsequently, a database of the ink-profiles was generated. The methods provide a useful tool for discriminating coloured inks in inkjet printer cartridges of different brands.

  3. Phytochemical Profile of Erythrina variegata by Using High-Performance Liquid Chromatography and Gas Chromatography-Mass Spectroscopy Analyses.

    Science.gov (United States)

    Muthukrishnan, Suriyavathana; Palanisamy, Subha; Subramanian, Senthilkumar; Selvaraj, Sumathi; Mari, Kavitha Rani; Kuppulingam, Ramalingam

    2016-08-01

    Natural products derived from plant sources have been utilized to treat patients with numerous diseases. The phytochemical constituents present in ethanolic leaf extract of Erythrina variegata (ELEV) were identified by using high-performance liquid chromatography (HPLC) and gas chromatography-mass spectroscopy (GC-MS) analyses. Shade dried leaves were powdered and extracted with ethanol for analyses through HPLC to identify selected flavonoids and through GC-MS to identify other molecules. The HPLC analysis of ELEV showed the presence of gallic and caffeic acids as the major components at concentrations of 2.0 ppm and 0.1 ppm, respectively, as well as other components. GC-MS analysis revealed the presence of 3-eicosyne; 3,7,11,15-tetramethyl-2-hexadecen-1-ol; butanoic acid, 3-methyl-3,7-dimethyl-6-octenyl ester; phytol; 1,2-benzenedicarboxylic acid, diundecyl ester; 1-octanol, 2-butyl-; squalene; and 2H-pyran, 2-(7-heptadecynyloxy) tetrahydro-derivative. Because pharmacopuncture is a new evolving natural mode that uses herbal extracts for treating patients with various ailments with minimum pain and maximum effect, the results of this study are particularly important and show that ELEV possesses a wide range of phytochemical constituents, as indicated above, as effective active principle molecules that can be used individually or in combination to treat patients with various diseases.

  4. Phytochemical Profile of Erythrina variegata by Using High-Performance Liquid Chromatography and Gas Chromatography-Mass Spectroscopy Analyses

    Directory of Open Access Journals (Sweden)

    Suriyavathana Muthukrishnan

    2016-08-01

    Full Text Available Natural products derived from plant sources have been utilized to treat patients with numerous diseases. The phytochemical constituents present in ethanolic leaf extract of Erythrina variegata (ELEV were identified by using high-performance liquid chromatography (HPLC and gas chromatography-mass spectroscopy (GC-MS analyses. Shade dried leaves were powdered and extracted with ethanol for analyses through HPLC to identify selected flavonoids and through GC-MS to identify other molecules. The HPLC analysis of ELEV showed the presence of gallic and caffeic acids as the major components at concentrations of 2.0 ppm and 0.1 ppm, respectively, as well as other components. GC-MS analysis revealed the presence of 3-eicosyne; 3,7,11,15-tetramethyl-2-hexadecen-1-ol; butanoic acid, 3-methyl-3,7-dimethyl-6-octenyl ester; phytol; 1,2-benzenedicarboxylic acid, diundecyl ester; 1-octanol, 2-butyl-; squalene; and 2H-pyran, 2-(7-heptadecynyloxy tetrahydro-derivative. Because pharmacopuncture is a new evolving natural mode that uses herbal extracts for treating patients with various ailments with minimum pain and maximum effect, the results of this study are particularly important and show that ELEV possesses a wide range of phytochemical constituents, as indicated above, as effective active principle molecules that can be used individually or in combination to treat patients with various diseases.

  5. Simultaneous achiral-chiral analysis of pharmaceutical compounds using two-dimensional reversed phase liquid chromatography-supercritical fluid chromatography.

    Science.gov (United States)

    Venkatramani, C J; Al-Sayah, Mohammad; Li, Guannan; Goel, Meenakshi; Girotti, James; Zang, Lisa; Wigman, Larry; Yehl, Peter; Chetwyn, Nik

    2016-02-01

    A new interface was designed to enable the coupling of reversed phase liquid chromatography (RPLC) and supercritical fluid chromatography (SFC). This online two-dimensional chromatographic system utilizing RPLC in the first dimension and SFC in the second was developed to achieve simultaneous achiral and chiral analysis of pharmaceutical compounds. The interface consists of an eight-port, dual-position switching valve with small volume C-18 trapping columns. The peaks of interest eluting from the first RPLC dimension column were effectively focused as sharp concentration pulses on small volume C-18 trapping column/s and then injected onto the second dimension SFC column. The first dimension RPLC separation provides the achiral purity result, and the second dimension SFC separation provides the chiral purity result (enantiomeric excess). The results are quantitative enabling simultaneous achiral, chiral analysis of compounds. The interface design and proof of concept demonstration are presented. Additionally, comparative studies to conventional SFC and case studies of the applications of 2D LC-SFC in pharmaceutical analysis is presented.

  6. SELECTION OF ROBUST COMBINATIONS OF EXTRACTION LIQUID COMPOSITION AND INTERNAL STANDARD - MONTE-CARLO SIMULATION OF IMPROVEMENT OF ASSAY-METHODS WITH LIQUID-LIQUID-EXTRACTION PRIOR TO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

    NARCIS (Netherlands)

    WIELING, J; COENEGRACHT, PMJ; MENSINK, CK; JONKMAN, JHG; DOORNBOS, DA

    1992-01-01

    The liquid-liquid extraction of a mixture of sulphonamides was achieved to examine the correlation between the experimental errors in the recoveries. Also, the impact of the composition of the extraction liquid was investigated. Six sulphonamides were repeatedly extracted simultaneously with ten dif

  7. Characterization of pitches by liquid chromatography using cellulose 3,5-dinitrobenzoate as the packing material

    Energy Technology Data Exchange (ETDEWEB)

    Arai, K.; Judo, R.; Ota, E. [Gunma University, Gunma (Japan). Dept. of Chemistry

    1997-08-01

    Characterization of coal tar, petroleum and PVC pitches by a liquid chromatography using cellulose 3,5-dinitrobenzoate (DNB-cellulose) as the packing material was investigated. Separation mechanism based on charge-transfer interaction between the dinitrobenzoyl group and polyaromatic compounds was expected to be useful for separation of the constituents of the pitches. First, 26 model polyaromatic compounds were tested to examine the characteristic feature of the packing material by liquid chromatography. The compounds were found to be classified roughly into four groups with different retention volume, principally according to the number of condensed rings. The nonplanar structure and aliphatic side chain of the polyaromatic compounds also affected the separation behavior. Both benzene soluble-hexane soluble and benzene soluble-hexane insoluble fractions of the three pitches were separated on DNB-cellulose. It was found that coal tar pitch contains relatively large amounts of some highly condensed polyaromatic compounds with condensed rings of 4 to 5; petroleum pitch has small amounts of such specific highly condensed polyaromatic compounds, while PVC pitch has large amounts of less condensed polyaromatic compounds and there is no significant amount of highly condensed compound in it. Thus DNB-cellulose was useful as the convenient packing material for liquid chromatography to characterize pitches.

  8. Recent development in liquid chromatography stationary phases for separation of Traditional Chinese Medicine components.

    Science.gov (United States)

    Jin, Hongli; Liu, Yanfang; Guo, Zhimou; Wang, Jixia; Zhang, Xiuli; Wang, Chaoran; Liang, Xinmiao

    2016-10-25

    Traditional Chinese Medicine (TCM) is an ancient medical practice which has been used to prevent and cure diseases for thousands of years. TCMs are frequently multi-component systems with mainly unidentified constituents. The study of the chemical compositions of TCMs remains a hotspot of research. Different strategies have been developed to manage the significant complexity of TCMs, in an attempt to determine their constituents. Reversed-phase liquid chromatography (RPLC) is still the method of choice for the separation of TCMs, but has many problems related to limited selectivity. Recently, enormous efforts have been concentrated on the development of efficient liquid chromatography (LC) methods for TCMs, based on selective stationary phases. This can improve the resolution and peak capacity considerably. In addition, high-efficiency stationary phases have been applied in the analysis of TCMs since the invention of ultra high-performance liquid chromatography (UHPLC). This review describes the advances in LC methods in TCM research from 2010 to date, and focuses on novel stationary phases. Their potential in the separation of TCMs using relevant applications is also demonstrated. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Comparison of liquid and supercritical fluid chromatography mobile phases for enantioselective separations on polysaccharide stationary phases.

    Science.gov (United States)

    Khater, Syame; Lozac'h, Marie-Anne; Adam, Isabelle; Francotte, Eric; West, Caroline

    2016-10-07

    Analysis and production of enantiomerically pure compounds is a major topic of interest when active pharmaceutical ingredients are concerned. Enantioselective chromatography has become a favourite both at the analytical and preparative scales. High-performance liquid chromatography (HPLC) and supercritical fluid chromatography (SFC) are dominating the scene and are often seen as complementary techniques. Nowadays, for economic and ecologic reasons, SFC may be preferred over normal-phase HPLC (NPLC) as it allows significant reductions in solvent consumption. However, the transfer of NPLC methods to SFC is not always straightforward. In this study, we compare the retention of achiral molecules and separation of enantiomers under supercritical fluid (carbon dioxide with ethanol or isopropanol) and liquid normal-phase (heptane with ethanol or isopropanol) elution modes with polysaccharide stationary phases in order to explore the differences between the retention and enantioseparation properties between the two modes. Chemometric methods (namely quantitative structure-retention relationships and discriminant analysis) are employed to compare the results obtained on a large set of analytes (171 achiral probes and 97 racemates) and gain some understanding on the retention and separation mechanisms. The results indicate that, contrary to popular belief, carbon dioxide - solvent SFC mobile phases are often weaker eluents than liquid mobile phases. It appears that SFC and NPLC elution modes provide different retention mechanisms. While some enantioseparations are unaffected, facilitating the transfer between the two elution modes, other enantioseparations may be drastically different due to different types and strength of interactions contributing to enantioselectivity.

  10. New Developments in Liquid Chromatography Mass Spectrometry for the Determination of Micropollutants

    Directory of Open Access Journals (Sweden)

    Zoraida Sosa-Ferrera

    2012-01-01

    Full Text Available The combination of liquid chromatography (LC with mass spectrometry (MS in the environmental field has appeared as a valuable tool for the determination of micropollutants. Several groups of compounds have been considered as particularly relevant (e.g., pharmaceuticals, hormones and other endocrine-disrupting, personal care products and their metabolites, flame retardants, surfactants, and plasticizers, among others since the same ones are continuously being released in the environment mainly as a result of the manufacturing processes, the disposal of unused or expired products, and the excreta. Because these micropollutants are not completely removed in the environment, very specific and sensitive analytical procedures are needed for their identification and quantification. High performance liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS (or LC-MS2 and especially time-of-flight mass spectrometry (TOF/MS, has allowed that many environmental contaminants that are highly polar or nonvolatile or have a high molecular weight to be analyzed or identified. In this work we present an overview focused on the developments of liquid chromatography mass spectrometry applied to the analysis of the main classes of micropollutants in aqueous and solid environmental samples. Various aspects of methodologies based on these techniques, including sample preparation (extraction/preconcentration and matrix effects, are discussed.

  11. Evaluation of a liquid chromatography method for quality control of methylated cyclodextrins.

    Science.gov (United States)

    Fougère, L; Elfakir, C; Lafosse, M

    2013-02-15

    Halo C18 column (fused core particles) and Chromolith RP18 column (monolith) were evaluated in liquid chromatography in order to analyze methylated-β-cyclodextrins (Me-β-CD) with various degrees of substitution, DS such as the number of methyl groups per cyclodextrin ring. Chromolith RP18 enables a performing analysis of Me-β-CD with low DS but is not suitable for dimethyl-β-cyclodextrins (DM-β-CD). On the other hand, Halo C18 column allows an improved fingerprint of CDs having a DS from 4.9 up to a value major than 14 and avoiding the use of various chromatographic systems. Thus, liquid chromatography performed with this column and an evaporative light scattering detector can be used as a generic system for methylated CD analysis. Moreover, fused core particles of Halo C18 column enables a rapid analysis and liquid chromatography coupled with electrospray-mass spectrometry appears as a powerful tool to determine co-elution and to characterize various isomers of complex methylated-β-cyclodextrin mixtures.

  12. Isolation and purification of heroin from heroin street samples by preparative high performance liquid chromatography.

    Science.gov (United States)

    Guo, Zhen; Zheng, Hui; Lu, Yanzhen; Wei, Yun

    2012-09-10

    The present study established a novel method using preparative high performance liquid chromatography to isolate and purify heroin·HCl from heroin street samples to be used as a reference standard. Different kinds of mobile phases and columns were used, ultimately the mobile phase consisting of hexane-isopropanol-methanol (65:28:7, v/v) and the SIL preparative column prepared in laboratory were selected as the final condition. Heroin was further purified by the drowning-out crystallization method using isopropanol-methanol (50:1, v/v) and hexane as drowning-out anti-solvents and salting-out agents, respectively. The purity was assessed by analytical high performance liquid chromatography and the confirmation of the chemical structure was performed by IR and NMR. About 110.7mg of heroin·HCl at a purity of over 99.52% was obtained from 180mg of heroin street samples which contained 156.15mg of heroin·HCl component by preparative high performance liquid chromatography. This method is suitable for preparing heroin standards in forensic science area.

  13. New high-performance liquid chromatography-dad method for analytical determination of arbutin and hydroquinone in rat plasma

    Directory of Open Access Journals (Sweden)

    F R Gallo

    2015-01-01

    Full Text Available Natural substances present in herbal preparations should be carefully used because they can give toxic or therapeutic effects despite of their amount or the way of administration. The safety of products of vegetable origin must be assessed before commercialisation by monitoring the active ingredients and their metabolites. This study was therefore designed to identify and quantify arbutin and its metabolite hydroquinone, naturally present in Arctostaphylos uva-ursi (L. Spreng plant in rat plasma, after an acute and subacute administration of aqueous arbutin solution in Wistar rats. For this purpose a reversed-phase high-performance liquid chromatography coupled with photodiode array detection was developed to assess the pharmacokinetic of arbutin and hydroquinone in plasma of female rats treated with aqueous arbutin solutions. The detection (arbutin: 0.0617 µg/ml and hydroquinone 0.0120 µg/ml and quantification (arbutin: 0.2060 µg/ml and hydroquinone: 0.0400 µg/ml limits were determined. At the arbutin concentration level of 10.7 µg/ml repeatability was 13.33% and its recovery 93.4±6.93%, while at the hydroquinone concentration level of 10.6 µg/ml repeatability was 11.66% and its recovery 92.9±7.75%. Furthermore the method was fully validated and the obtained data indicate that the new method provides good performances.

  14. New High-performance Liquid Chromatography-DAD Method for Analytical Determination of Arbutin and Hydroquinone in Rat Plasma.

    Science.gov (United States)

    Gallo, F R; Pagliuca, G; Multari, G; Panzini, G; D'amore, E; Altieri, I

    2015-01-01

    Natural substances present in herbal preparations should be carefully used because they can give toxic or therapeutic effects despite of their amount or the way of administration. The safety of products of vegetable origin must be assessed before commercialisation by monitoring the active ingredients and their metabolites. This study was therefore designed to identify and quantify arbutin and its metabolite hydroquinone, naturally present in Arctostaphylos uva-ursi (L.) Spreng plant in rat plasma, after an acute and subacute administration of aqueous arbutin solution in Wistar rats. For this purpose a reversed-phase high-performance liquid chromatography coupled with photodiode array detection was developed to assess the pharmacokinetic of arbutin and hydroquinone in plasma of female rats treated with aqueous arbutin solutions. The detection (arbutin: 0.0617 µg/ml and hydroquinone 0.0120 µg/ml) and quantification (arbutin: 0.2060 µg/ml and hydroquinone: 0.0400 µg/ml) limits were determined. At the arbutin concentration level of 10.7 µg/ml repeatability was 13.33% and its recovery 93.4±6.93%, while at the hydroquinone concentration level of 10.6 µg/ml repeatability was 11.66% and its recovery 92.9±7.75%. Furthermore the method was fully validated and the obtained data indicate that the new method provides good performances.

  15. Improved high-performance liquid chromatography (HPLC) method for qualitative and quantitative analysis of allantoin in Zea mays.

    Science.gov (United States)

    Haghi, Ghasem; Arshi, Rohollah; Safaei, Alireza

    2008-02-27

    A high-performance liquid chromatography (HPLC) method for the qualitative and quantitative analysis of allantoin in silk and seed of Zea mays has been developed. Allantoin separation in crude extract was achieved using a C 18 column and phosphate buffer solution (pH 3.0) as a mobile phase at ambient temperature at a flow rate of 1.0 mL/min and detected at 210 nm. The results showed that the amount of allantoin in samples was between 14 and 271 mg/100 g of dry plant material. A comprehensive validation of the method including sensitivity, linearity, repeatability, and recovery was conducted. The calibration curve was linear over the range of 0.2-200 microg/mL with a correlation coefficient of r2>0.999. Limit of detection (LOD, S/N=3) and limit of quantification (LOQ) values of the allantoin were 0.05 and 0.2 microg/mL (1.0 and 4.0 ng) respectively. The relative standard deviation (RSD) value of the repeatability was reported within 1.2%. The average recovery of allantoin added to samples was 100.6% with RSD of 1.5%.

  16. Surveillance of the Army’s Propellant Stockpile: Analysis of Stabilizer Content by High Performance Liquid Chromatography

    Science.gov (United States)

    1990-10-01

    high performance liquid chromatography to monitor the level of stabilizer and its daughter products in propellant. Three of those methods are presented along with statistics and some comments about their

  17. HIGH PERFORMANCE LIQUID CHROMATOGRAPHY OF COBALT(III) MIXED LIGAND COMPLEXES WITH ACETYLACETONATE AND OXINATE AND MONOMETHYLOXINATE IONS

    National Research Council Canada - National Science Library

    Kidani, Yoshinori; Naga, Shinobu; Koike, Hisashi

    1976-01-01

    In the presence of Co(III) mixed ligand complexes with acetylacetonate, and oxinate and monomethyloxinate ions, the authors attempted to employ high performance liquid chromatography, HPLC, for the separation and purification...

  18. Quantitative determination of paralytic shellfish poisoning toxins in shellfish using prechromatography oxidation and liquid chromatography with fluorescence detection: interlaboratory study

    NARCIS (Netherlands)

    Lawrence, J.F.; Niedzwiadek, B.; Menard, C.; Wezenbeek, P.

    2004-01-01

    An interlaboratory study was conducted for the determination of paralytic shellfish poisoning (PSP) toxins in shellfish. The method used liquid chromatography with fluorescence detection after prechromatographic oxidation of the toxins with hydrogen peroxide and periodate. The PSP toxins studied

  19. Chromatographic behavior of small organic compounds in low-temperature high-performance liquid chromatography using liquid carbon dioxide as the mobile phase.

    Science.gov (United States)

    Motono, Tomohiro; Nagai, Takashi; Kitagawa, Shinya; Ohtani, Hajime

    2015-07-01

    Low-temperature high-performance liquid chromatography, in which a loop injector, column, and detection cell were refrigerated at -35ºC, using liquid carbon dioxide as the mobile phase was developed. Small organic compounds (polyaromatic hydrocarbons, alkylbenzenes, and quinones) were separated by low-temperature high-performance liquid chromatography at temperatures from -35 to -5ºC. The combination of liquid carbon dioxide mobile phase with an octadecyl-silica (C18 ) column provided reversed phase mode separation, and a bare silica-gel column resulted in normal phase mode separation. In both the cases, nonlinear behavior at approximately -15ºC was found in the relationship between the temperature and the retention factors of the analytes (van't Hoff plots). In contrast to general trends in high-performance liquid chromatography, the decrease in temperature enhanced the separation efficiency of both the columns.

  20. Critical Evaluation of Acetylcholine Determination in Rat Brain Microdialysates using Ion-Pair Liquid Chromatography with Amperometric Detection

    Directory of Open Access Journals (Sweden)

    Yvette Michotte

    2008-08-01

    Full Text Available Liquid chromatography with amperometric detection remains the most widely used method for acetylcholine quantification in microdialysis samples. Separation of acetylcholine from choline and other matrix components on a microbore chromatographic column (1 mm internal diameter, conversion of acetylcholine in an immobilized enzyme reactor and detection of the produced hydrogen peroxide on a horseradish peroxidase redox polymer coated glassy carbon electrode, achieves sufficient sensitivity for acetylcholine quantification in rat brain microdialysates. However, a thourough validation within the concentration range required for this application has not been carried out before. Furthermore, a rapid degradation of the chromatographic columns and enzyme systems have been reported. In the present study an ion-pair liquid chromatography assay with amperometric detection was validated and its long-term stability evaluated. Working at pH 6.5 dramatically increased chromatographic stability without a loss in sensitivity compared to higher pH values. The lower limit of quantification of the method was 0.3 nM. At this concentration the repeatability was 15.7%, the inter-day precision 8.7% and the accuracy 103.6%. The chromatographic column was stable over 4 months, the immobilized enzyme reactor up to 2-3 months and the enzyme coating of the amperometric detector up to 1-2 months. The concentration of acetylcholine in 30 μl microdialysates obtained under basal conditions from the hippocampus of freely moving rats was 0.40 ± 0.12 nM (mean ± SD, n = 30. The present method is therefore suitable for acetylcholine determination in rat brain microdialysates.

  1. Analysis of macrolide antibiotics, using liquid chromatography-mass spectrometry, in food, biological and environmental matrices.

    Science.gov (United States)

    Wang, Jian

    2009-01-01

    Macrolides are a group of antibiotics that have been widely used in human medical and veterinary practices. Analysis of macrolides and related compounds in food, biological, and environmental matrices continue to be the focus of scientists for the reasons of food safety, pharmacokinetic studies, and environmental concerns. This article presents an overview on the primary biological properties of macrolides and their associated analytical issues, including extraction, liquid chromatography-mass spectrometry (LC-MS), method validation, and measurement uncertainty. The main techniques that have been used to extract macrolides from various matrices are solid-phase extraction and liquid-liquid extraction. Conventional liquid chromatography (LC) with C18 columns plays a dominant role for the determination of macrolides, whereas ultra-performance liquid chromatography (UPLC) along with sub-2 microm particle C18 columns reduces run time and improves sensitivity. Mass spectrometry (MS), serving as a universal detection technique, has replaced ultraviolet (UV), fluorometric, and electrochemical detection for multi-macrolide analysis. The triple-quadrupole (QqQ), quadrupole ion trap (QIT), triple-quadrupole linear ion trap, time-of-flight (TOF), and quadrupole time-of-flight (QqTOF) mass spectrometers are current choices for the determination of macrolides, including quantification, confirmation, identification of their degradation products or metabolites, and structural elucidation. LC or UPLC coupled to a triple-quadrupole mass spectrometer operated in the multiple-reaction monitoring (MRM) mode (LC/MS/MS) is the first choice for quantification. UPLC-TOF or UPLC-QqTOF has been recognized as an emerging technique for accurate mass measurement and unequivocal identification of macrolides and their related compounds.

  2. Dispersive liquid-liquid microextraction combined with gas chromatography-electron capture detection for the determination of polychlorinated biphenyls in soils

    Energy Technology Data Exchange (ETDEWEB)

    Hu Jia [Department of Chemical Engineering, Zhejiang University, Hangzhou, Zhejiang 310027 (China); Key Laboratory of Pesticide and Chemical Biology of Ministry of Education, Central China Normal University, Wuhan 430079 (China); Fu Lingyan; Zhao Xinna; Liu Xiujuan [Key Laboratory of Pesticide and Chemical Biology of Ministry of Education, Central China Normal University, Wuhan 430079 (China); Wang Huili; Wang Xuedong [School of Environmental Science and Public Health, Wenzhou Medical College, Wenzhou 325035 (China); Dai Liyan, E-mail: dailiyan@zju.edu.cn [Department of Chemical Engineering, Zhejiang University, Hangzhou, Zhejiang 310027 (China)

    2009-04-27

    In this article, dispersive liquid-liquid microextraction (DLLME) and gas chromatography-electron capture detection (GC-ECD) were presented for the extraction and determination of five polychlorinated biphenyls (PCBs) in soil samples. Acetone was used as extraction solvent for the extraction of PCBs from soil samples. In DLLME, the target analytes in the extraction solvent were rapidly transferred from the acetone extract to chlorobenzene when the extraction process began. The main advantages of this method are quick speed, high enrichment factor, high recovery and good repeatability. Under the optimum conditions, the method yields a linear calibration curve in the concentration range from 2 to 2000 {mu}g kg{sup -1}for PCB 52, and 0.4 to 400 {mu}g kg{sup -1} for other target analytes. Coefficients of correlation (r{sup 2}) ranged from 0.9993 to 0.9999. The repeatability was tested by spiking soil samples at a concentration level of 10 {mu}g kg{sup -1} for PCBs. The relative standard deviations (RSDs, n = 11) varied between 2.2% and 6.4%. The limits of detection (LODs), based on signal-to-noise (S/N) of 3, were between 0.20 and 0.50 {mu}g kg{sup -1}. The relative recoveries of the five PCBs from soil S1, S2 and S3 at spiking levels of 10, 20 and 50 {mu}g kg{sup -1} were in the range of 88.70-103.8%, 82.50-106.3% and 82.30-113.6%, respectively. Therefore, DLLME combined with GC-ECD can be successfully applied for the determination of trace PCB residues in real soil samples.

  3. Preparation and Characterization of a Polymeric Monolithic Column for Use in High-Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    Bindis, Michael P.; Bretz, Stacey Lowery; Danielson, Neil D.

    2011-01-01

    The high-performance liquid chromatography (HPLC) experiment, most often done in the undergraduate analytical instrumentation laboratory course, generally illustrates reversed-phase chromatography using a commercial C[subscript]18 silica column. To avoid the expense of periodic column replacement and introduce a choice of columns with different…

  4. Direct solid-phase microextraction combined with gas and liquid chromatography for the determination of lidocaine in human urine

    NARCIS (Netherlands)

    Koster, E.H M; Hofman, N.S K; de Jong, G.J.

    1998-01-01

    Solid-phase microextraction (SPME) has been combined with gas chromatography (GC) and liquid chromatography (LC) for the determination of lidocaine in human urine. A polydimethylsiloxane (PDMS) coated fibre was directly immersed into buffered urine. Extraction conditions such as time, pH, ionic stre

  5. Determination of polar organophosphorus pesticides in vegetables and fruits using liquid chromatography with tandem mass spectrometry: Selection of extraction solvent

    NARCIS (Netherlands)

    Mol, H.G.J.; Dam, R.C.J. van; Steijger, O.M.

    2003-01-01

    A method based on liquid chromatography (LC)-mass spectrometry (MS)/MS was developed for sensitive determination of a number of less gas chromatography (GC)-amenable organophosphorus pesticides (OPs; acephate, methamidophos, monocrotophos, omethoate, oxydemeton-methyl and vamidothion) in cabbage and

  6. Determination of polar organophosphorus pesticides in vegetables and fruits using liquid chromatography with tandem mass spectrometry: Selection of extraction solvent

    NARCIS (Netherlands)

    Mol, H.G.J.; Dam, R.C.J. van; Steijger, O.M.

    2003-01-01

    A method based on liquid chromatography (LC)-mass spectrometry (MS)/MS was developed for sensitive determination of a number of less gas chromatography (GC)-amenable organophosphorus pesticides (OPs; acephate, methamidophos, monocrotophos, omethoate, oxydemeton-methyl and vamidothion) in cabbage and

  7. Preparation and Characterization of a Polymeric Monolithic Column for Use in High-Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    Bindis, Michael P.; Bretz, Stacey Lowery; Danielson, Neil D.

    2011-01-01

    The high-performance liquid chromatography (HPLC) experiment, most often done in the undergraduate analytical instrumentation laboratory course, generally illustrates reversed-phase chromatography using a commercial C[subscript]18 silica column. To avoid the expense of periodic column replacement and introduce a choice of columns with different…

  8. tRNA separation by high-performance liquid chromatography using an aggregate of ODS-Hypersil and trioctylmethylammonium chloride

    NARCIS (Netherlands)

    Bischoff, Rainer; Graeser, E.; Mclaughlin, L.W.

    1983-01-01

    High-performance liquid chromatography on a reversed-phase support treated with a tetraalkylammonium salt was used to separate tRNAs from baker's yeast. While resolution by this column appears to result from both anion-exchange and reversed-phase chromatography, it is the hydrophobic interactions wh

  9. A Liquid Chromatography – Tandem Mass Spectrometry Approach for the Identification of Mebendazole Residue in Pork, Chicken, and Horse

    Science.gov (United States)

    Lee, Ji Sun; Cho, Soo Hee; Lim, Chae Mi; Chang, Moon Ik; Joo, Hyun Jin; Park, Hyun Jin

    2017-01-01

    A confirmatory and quantitative method of liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the determination of mebendazole and its hydrolyzed and reduced metabolites in pork, chicken, and horse muscles was developed and validated in this study. Anthelmintic compounds were extracted with ethyl acetate after sample mixture was made alkaline followed by liquid chromatographic separation using a reversed phase C18 column. Gradient elution was performed with a mobile phase consisting of water containing 10 mM ammonium formate and methanol. This confirmatory method was validated according to EU requirements. Evaluated validation parameters included specificity, accuracy, precision (repeatability and within-laboratory reproducibility), analytical limits (decision limit and detection limit), and applicability. Most parameters were proved to be conforming to the EU requirements. The decision limit (CCα) and detection capability (CCβ) for all analytes ranged from 15.84 to 17.96 μgkg-1. The limit of detection (LOD) and the limit of quantification (LOQ) for all analytes were 0.07 μgkg-1 and 0.2 μgkg-1, respectively. The developed method was successfully applied to monitoring samples collected from the markets in major cities and proven great potential to be used as a regulatory tool to determine mebendazole residues in animal based foods. PMID:28085912

  10. A New Liquid Chromatography-Tandem Mass Spectrometry Method for Determination of Bisoprolol in Human Plasma Samples

    OpenAIRE

    Gabriela Peste; Nela Bibire; Mihai Apostu; Aurel Vlase; Corneliu Oniscu

    2009-01-01

    Liquid chromatography (LC) coupled with mass spectrometry (MS) detection is one of the most powerful analytical tools for organic compound analysis. The advantages of using LC/MS methods over HPLC methods include: selectivity, chromatographic integrity, peak assignment, structural information, and rapid method development. In this paper, a new liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the determination of bisoprolol in human plasma s...

  11. Preparative isolation and analysis of alcohol dehydrogenase inhibitors from Glycyrrhiza uralensis root using ultrafiltration combined with high-performance liquid chromatography and high-speed countercurrent chromatography.

    Science.gov (United States)

    Chen, Miao; Liu, Liangliang; Chen, Xiaoqing

    2014-07-01

    A simple, rapid, and effective assay based on ultrafiltration combined with high-performance liquid chromatography and high-speed countercurrent chromatography was developed for screening and purifying alcohol dehydrogenase inhibitors from Glycyrrhiza uralensis root extract. Experiments were carried out to optimize binding conditions including alcohol dehydrogenase concentration, incubation time, temperature, and pH. By comparing the chromatograms, three compounds were found possessing alcohol dehydrogenase binding activity in Glycyrrhiza uralensis root. Under the target-guidance of ultrafiltration combined with the high-performance liquid chromatography experiment, liquiritin (1), isoliquiritin (2), and liquiritigenin (3) were separated by high-speed countercurrent chromatography using ethyl acetate/methanol/water (5:1:4) as the solvent system. The alcohol dehydrogenase inhibitory activities of these three isolated compounds were assessed; compound 2 showed strongest inhibitory activity with an IC50 of 8.95 μM. The results of the present study indicated that the combinative method using ultrafiltration, high-performance liquid chromatography and high-speed countercurrent chromatography could be widely applied for the rapid screening and isolation of enzyme inhibitors from complex mixtures.

  12. Incorporation of ionic liquid into porous polymer monoliths to enhance the separation of small molecules in reversed-phase high-performance liquid chromatography.

    Science.gov (United States)

    Wang, Jiafei; Bai, Ligai; Wei, Zhen; Qin, Junxiao; Ma, Yamin; Liu, Haiyan

    2015-06-01

    An ionic liquid was incorporated into the porous polymer monoliths to afford stationary phases with enhanced chromatographic performance for small molecules in reversed-phase high-performance liquid chromatography. The effect of the ionic liquid in the polymerization mixture on the performance of the monoliths was studied in detail. While monoliths without ionic liquid exhibited poor resolution and low efficiency, the addition of ionic liquid to the polymerization mixture provides highly increased resolution and high efficiency. The chromatographic performances of the monoliths were demonstrated by the separations of various small molecules including aromatic hydrocarbons, isomers, and homologues using a binary polar mobile phase. The present column efficiency reached 27 000 plates/m, which showed that the ionic liquid monoliths are alternative stationary phases in the separation of small molecules by high-performance liquid chromatography.

  13. Determination of nitrofuran metabolites in shrimp by high performance liquid chromatography with fluorescence detection and liquid chromatography-tandem mass spectrometry using a new derivatization reagent.

    Science.gov (United States)

    Du, Na-Na; Chen, Ming-Ming; Sheng, Liang-Quan; Chen, Shui-Sheng; Xu, Hua-Jie; Liu, Zhao-Di; Song, Chong-Fu; Qiao, Rui

    2014-01-31

    A high performance liquid chromatography with fluorescence detection (HPLC-FLD) method for the simultaneous determination of total nitrofuran metabolite residues (furazolidone, furaltadone, nitrofurantoin, and nitrofurazone) in shrimp was developed. The method involves the acid hydrolysis of protein-bound metabolites, followed by the derivatization of the freed metabolites with the new fluorescent derivatization reagent 2-hydroxy-1-naphthaldehyde (HN) and subsequent liquid-liquid extraction (LLE). Separation is achieved on a YMC-Pack Polymer C18 column under alkaline conditions, and the high fluorescence intensity of the derivatives at an emission wavelength Em=463nm (Ex=395nm) enables, for the first time, their simultaneous determination in shrimp at concentrations as low as 1μg/kg by HPLC-FLD. The method was validated using blank shrimp fortified with all four metabolites at 0.5, 1.0 and 2.0μg/kg. Recoveries were >87% with relative standard deviations of HPLC-FLD were in very good agreement with those obtained by LC-MS/MS analysis.

  14. Discussions about high performance liquid chromatography upgrading to ion chromatography%液相色谱升级改造为离子色谱问题探讨

    Institute of Scientific and Technical Information of China (English)

    施超欧; 马浩; 姚宝龙; 黄彩勇

    2014-01-01

    离子色谱作为色谱的一个分支,在原理和仪器结构上与液相色谱密切相关。本文总结了液相色谱升级为离子改造色谱的经验。%As a part of chromatography ,the functions and structures of instruments between high per-formance liquid chromatography and ion chromatography are closely related .In this paper ,HPLC upgra-ded to IC was discused .

  15. Validation of high performance liquid chromatography method for determination of meloxicam loaded PEGylated nanocapsules

    Directory of Open Access Journals (Sweden)

    Francine Rodrigues Ianiski

    2015-12-01

    Full Text Available abstract A method to ensure that an analytical method will produce reliable and interpretable information about the sample must first be validated, making sure that the results can be trusted and traced. In this study, we propose to validate an analytical high performance liquid chromatography (HPLC method for the quantitation of meloxicam loaded PEGylated nanocapsules(M-PEGNC. We performed a validation study, evaluated parameters including specificity, linearity, quantification limit, detection limit, accuracy, precision and robustness. PEGylated nanocapsules were prepared by interfacial deposition of preformed polymer, and the particle size, polydispersity index, zeta potential, pH value and encapsulation efficiency were characterized. The proposed HPLC method provides selective, linear results in the range of 1.0-40.0 μg/mL; quantification and detection limits were 1.78 μg/mL and 0.59 μg/mL, respectively; relative standard deviation for repeatability was 1.35% and intermediate precision was 0.41% and 0.61% for analyst 1 and analyst 2, respectively; accuracy between 99.23 and 101.79%; robustness between 97.13 and 98.45% for the quantification of M-PEGNC. Mean particle diameters were 261 ± 13 nm and 249 ± 20 nm, polydispersity index was 0.15 ± 0.07 and 0.17 ± 0.06, pH values were 5.0 ± 0.2 and 5.2 ± 0.1, and zeta-potential values were -37.9 ± 3.2 mV e -31.8 ± 2.8 mV for M-PEGNC and placebo(B-PEGNC, respectively. In conclusion, the proposed analytical method is suitable for the quality control of M-PEGNC. Moreover, suspensions showed monomodal size distributions and low polydispersity index indicating high homogeneity of formulations with narrow size distributions, and appropriate pH and zeta potential. The extraction process was efficient for release of meloxicam from nanostructured systems.

  16. Extraction and determination of hormones in cosmetics by homogeneous ionic liquid microextraction high-performance liquid chromatography.

    Science.gov (United States)

    Kang, Mingqin; Sun, Shuo; Li, Na; Zhang, Daihui; Chen, Mingyan; Zhang, Hanqi

    2012-08-01

    The homogeneous ionic liquid microextraction was applied to the extraction of hormones from cosmetics and the hormones were determined by high-performance liquid chromatography. 1-Hexyl-3-methylimidazolium tetrafluoroborate was used as extraction solvent. Ammonium hexafluorophosphate as used as ion-pairing agent. Several experimental parameters, including the volume of 1-hexyl-3-methylimidazolium tetrafluoroborate, amount of ammonium hexafluorophosphate and sodium chloride, extraction and centrifuge time, and the pH value, were optimized. The limits of detection and quantification for the analytes ranged from 0.03 to 0.24 ng/mL and from 0.10 to 0.79 ng/mL, respectively. The precision for determining the hormones was lower than 5.2%. The proposed method was successfully developed for the determination of hormones in real cosmetic samples.

  17. Determination of Four Pesticides in Soil by Homogeneous Ionic Liquid-based Microextraction Coupled with High-performance Liquid Chromatography

    Institute of Scientific and Technical Information of China (English)

    YAN Rui; SHAO Ming-yuan; LIANG Zhen-fen; ZHANG Han-qi; YU Ai-min

    2013-01-01

    Homogeneous ionic liquid microextraction was developed for the simultaneceus extraction of dimethomorph,mefenacet,isoprothiolane and oxadiazon from soil.1-Butyl-3-methylimidazolium tetrafluoroborate was used as extraction solvent,and ammonium hexafluorophosphate was used as ion-pairing agent.High-performance liquid chromatography(HPLC) was employed for separation and determination of the analytes.The calibration curves show good linear relationship(r>0.9988).The recoveries are between 74.2% and 97.9% with relative standard deviations(RSDs) lower than 5.97%.The present method is free of volatile organic solvents,and expenditures of sample,extraction time and solvent are lower,compared with ultrasonic and Soxhlet extraction.There was no obvious difference in the extraction recoveries of pesticides obtained by the three extraction methods.

  18. Determination of parabens in serum by liquid chromatography-tandem mass spectrometry: Correlation with lipstick use.

    Science.gov (United States)

    Tahan, Gabriella Padovani; Santos, Nayara de Kássia Souza; Albuquerque, Ana Carolina; Martins, Isarita

    2016-08-01

    Parabens are the most widely used preservative and are considered to be relatively safe compounds. However, studies have demonstrated that they may have estrogenic activity, and there is ongoing debate regarding the safety and potential cancer risk of using products containing these compounds. In the present work, liquid chromatography-tandem mass spectrometry was applied to determine methylparaben and propylparaben concentrations in serum, and the results were correlated with lipstick application. Samples were analyzed using liquid-liquid extraction, followed by liquid chromatography-tandem mass spectrometry. The validation results demonstrated the linearity of the method over a range of 1-20 ng/mL, in addition to the method's precision and accuracy. A statistically significant difference was demonstrated between serum parabens in women who used lipstick containing these substances compared with those not using this cosmetic (p = 0.0005 and 0.0016, respectively), and a strong association was observed between serum parabens and lipstick use (Spearman correlation = 0.7202). Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Deformation and degradation of polymers in ultra-high-pressure liquid chromatography.

    Science.gov (United States)

    Uliyanchenko, Elena; van der Wal, Sjoerd; Schoenmakers, Peter J

    2011-09-28

    Ultra-high-pressure liquid chromatography (UHPLC) using columns packed with sub-2 μm particles has great potential for separations of many types of complex samples, including polymers. However, the application of UHPLC for the analysis of polymers meets some fundamental obstacles. Small particles and narrow bore tubing in combination with high pressures generate significant shear and extensional forces in UHPLC systems, which may affect polymer chains. At high stress conditions flexible macromolecules may become extended and eventually the chemical bonds in the molecules can break. Deformation and degradation of macromolecules will affect the peak retention and the peak shape in the chromatogram, which may cause errors in the obtained results (e.g. the calculated molecular-weight distributions). In the present work we explored the limitations of UHPLC for the analysis of polymers. Degradation and deformation of macromolecules were studied by collecting and re-injecting polymer peaks and by off-line two-dimensional liquid chromatography. Polystyrene standards with molecular weight of 4 MDa and larger were found to degrade at UHPLC conditions. However, for most polymers degradation could be avoided by using low linear velocities. No degradation of 3-MDa PS (and smaller) was observed at linear velocities up to 7 mm/s. The column frits were implicated as the main sources of polymer degradation. The extent of degradation was found to depend on the type of the column and on the column history. At high flow rates degradation was observed without a column being installed. We demonstrated that polymer deformation preceded degradation. Stretched polymers eluted from the column in slalom chromatography mode (elution order opposite to that in SEC or HDC). Under certain conditions we observed co-elution of large and small PS molecules though a convolution of slalom chromatography and hydrodynamic chromatography.

  20. Ionic liquid foam floatation coupled with ionic liquid dispersive liquid-liquid microextraction for the separation and determination of estrogens in water samples by high-performance liquid chromatography with fluorescence detection.

    Science.gov (United States)

    Zhang, Rui; Wang, Chuanliu; Yue, Qiaohong; Zhou, Tiecheng; Li, Na; Zhang, Hanqi; Hao, Xiaoke

    2014-11-01

    An ionic liquid foam floatation coupled with ionic liquid dispersive liquid-liquid microextraction method was proposed for the extraction and concentration of 17-α-estradiol, 17-β-estradiol-benzoate, and quinestrol in environmental water samples by high-performance liquid chromatography with fluorescence detection. 1-Hexyl-3-methylimidazolium tetrafluoroborate was applied as foaming agent in the foam flotation process and dispersive solvent in microextraction. The introduction of the ion-pairing and salting-out agent NH4 PF6 was beneficial to the improvement of recoveries for the hydrophobic ionic liquid phase and analytes. Parameters of the proposed method including concentration of 1-hexyl-3-methylimidazolium tetrafluoroborate, flow rate of carrier gas, floatation time, types and concentration of ionic liquids, salt concentration in samples, extraction time, and centrifugation time were evaluated. The recoveries were between 98 and 105% with relative standard deviations lower than 7% for lake water and well water samples. The isolation of the target compounds from the water was found to be efficient, and the enrichment factors ranged from 4445 to 4632. This developing method is free of volatile organic solvents compared with regular extraction. Based on the unique properties of ionic liquids, the application of foam floatation, and dispersive liquid-liquid microextraction was widened.

  1. Comprehensive two-dimensional liquid chromatography with on-line Fourier-transform-infrared-spectroscopy detection for the characterization of copolymers

    NARCIS (Netherlands)

    Kok, S.J.; Hankemeier, T.; Schoenmakers, P.J.

    2005-01-01

    The on-line coupling of comprehensive two-dimensional liquid chromatography (liquid chromatography × size-exclusion chromatography, LC × SEC) and infrared (IR) spectroscopy has been realized by means of an IR flow cell. The system has been assessed by the functional-group analysis of a series of

  2. Comprehensive two-dimensional liquid chromatography with on-line Fourier-transform-infrared-spectroscopy detection for the characterization of copolymers

    NARCIS (Netherlands)

    Kok, S.J.; Hankemeier, T.; Schoenmakers, P.J.

    2005-01-01

    The on-line coupling of comprehensive two-dimensional liquid chromatography (liquid chromatography × size-exclusion chromatography, LC × SEC) and infrared (IR) spectroscopy has been realized by means of an IR flow cell. The system has been assessed by the functional-group analysis of a series of sty

  3. Multimycotoxin analysis in water and fish plasma by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Tolosa, J; Font, G; Mañes, J; Ferrer, E

    2016-02-01

    High performance liquid chromatography-mass spectrometry was used for the determination of 15 mycotoxins in water and fish plasma samples, including aflatoxins, fumonisins, ochratoxin A, sterigmatocistin, fusarenon-X and emerging Fusarium mycotoxins. In this work, dispersive liquid-liquid microextraction (DLLME) was assessed as a sample treatment for the simultaneous extraction of mycotoxins. Results showed differences in recovery assays when different extraction solvents were employed. Ethyl acetate showed better recoveries for the major part of mycotoxins analyzed, except for aflatoxins B2, G1 and G2, which showed better recoveries when employing chloroform as extractant solvent. Fumonisins and beauvericin exhibited low recoveries in both water and plasma. This method was validated according to guidelines established by European Commission and has shown to be suitable to be applied in dietary and/or toxicokinetic studies in fish where is necessary to check mycotoxin contents in rearing water and fish plasma.

  4. Use of ionic liquids as stationary phases in hyphenated gas chromatography techniques.

    Science.gov (United States)

    Ragonese, Carla; Sciarrone, Danilo; Tranchida, Peter Quinto; Dugo, Paola; Mondello, Luigi

    2012-09-14

    In the past decades a consistent number of ionic liquids have been specifically synthesized and evaluated as stationary phase in gas chromatography. Ionic liquid, also defined as "molten salts", are a class of organic non-molecular solvents liquid at room temperature (RTILs) that satisfy most of the requirements of a GC stationary phase, among which a high viscosity, the possibility to tune the selectivity (by changing the cation-anion combination) and a high thermal stability. The choice of the proper stationary phase plays a key role in the improvement/optimization of a GC method, and although the use of IL as stationary phases is still not well-established, the general interest in their applications has greatly increased, thanks to their particular properties. The present contribution provides an overview on recent evaluations and applications of IL stationary phases, focusing in particular on the use of these novel tools in hyphenated GC-based techniques.

  5. Analysis of Whiskey by Dispersive Liquid-Liquid Microextraction Coupled with Gas Chromatography/Mass Spectrometry: An Upper Division Analytical Chemistry Experiment Guided by Green Chemistry

    Science.gov (United States)

    Owens, Janel E.; Zimmerman, Laura B.; Gardner, Michael A.; Lowe, Luis E.

    2016-01-01

    Analysis of whiskey samples prepared by a green microextraction technique, dispersive liquid-liquid microextraction (DLLME), before analysis by a qualitative gas chromatography-mass spectrometry (GC/MS) method, is described as a laboratory experiment for an upper division instrumental methods of analysis laboratory course. Here, aroma compounds in…

  6. Screening anti-tumor compounds from Ligusticum wallichii using cell membrane chromatography combined with high-performance liquid chromatography and mass spectrometry.

    Science.gov (United States)

    Zhang, Tao; Ding, Yuanyuan; An, Hongli; Feng, Liuxin; Wang, Sicen

    2015-07-14

    Tyrosine 367 Cysteine-fibroblast growth factor receptor 4 cell membrane chromatography combined with high-performance liquid chromatography and mass spectrometry was developed. Tyrosine 367 Cysteine-HEK293 cells were used as cell membrane stationary phase. Specificity and reproducibility of the cell membrane chromatography was evaluated using 1-tert-butyl-3-{2-[4-(diethylamino)butylamino]-6-(3,5-dimethoxyphenyl)pyrido[2,3-d]pyrimidin-7-yl}urea, Nimodipine and dexamethasone acetate. Then, anti-tumor components acting on Tyrosine 367 Cysteine-fibroblast growth factor receptor 4 were screened and identified from extracts of Ligusticum wallichii. Components from the extract were retained on the cell membrane chromatographic column. The retained fraction was directly eluted into high-performance liquid chromatography with mass spectrometry system for separation and identification. Finally, Levistolide A was identified as an active component from Ligusticum wallichii extracts. The 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl-tetrazolium bromide-formazan colorimetric assay revealed that Levistolide A inhibits proliferation of overexpressing the mutated receptor cells with dose-dependent manner. Phosphorylation of fibroblast growth factor receptor 4 was also decrease under Levistolide A treatment. Flex dock simulation verified that Levistolide A could bind with the tyrosine kinase domain of fibroblast growth factor receptor 4. Therefore, Levistolide A screened by the cell membrane chromatography combined with high-performance liquid chromatography and mass spectrometry can arrest cell growth. In conclusion, the two-dimensional high-performance liquid chromatography method can screen and identify potential anti-tumor ingredients which specifically act on the tyrosine kinase domain of the mutated fibroblast growth factor receptor 4. This article is protected by copyright. All rights reserved.

  7. Home-made online hyphenation of pressurized liquid extraction, turbulent flow chromatography, and high performance liquid chromatography, Cistanche deserticola as a case study.

    Science.gov (United States)

    Song, Qingqing; Li, Jun; Liu, Xiao; Zhang, Yuan; Guo, Liping; Jiang, Yong; Song, Yuelin; Tu, Pengfei

    2016-03-18

    Incompatibility between the conventional pressurized liquid extraction (PLE) devices and high performance liquid chromatography (HPLC) extensively hinders direct and green chemical analysis of herbal materials. Herein, a facile PLE module was configured, and then it was online hyphenated with HPLC via a turbulent flow chromatography (TFC) column. Regarding PLE module, a long PEEK tube (0.13 × 1000 mm) was employed to generate desired pressure (approximately 13.0 MPa) when warm acidic water (70 °C) was delivered as extraction solvent at a high flow rate (2.5 mL/min), and a hollow guard column (3.0 × 4.0 mm) was implemented to hold crude materials. Effluent was collected from the outlet of PEEK tube, concentrated, and subjected onto HPLC coupled with hybrid ion trap-time of flight mass spectrometer to assess the extraction efficiency and also to profile the chemical composition of Cistanche deserticola (CD) that is honored as "Ginseng of the desert". Afterwards, a TFC column was introduced to accomplish online transmission of low molecule weight components from PLE module to HPLC coupled with diode array detection, and two electronic 6-port/2-channel valves were in charge of alternating the whole system between extraction (0-3.0 min) and elution (3.0-35.0 min) phases. Quantitative method was developed and validated for simultaneous determination of eight primary phenylethanoid glycosides in CD using online PLE-TFC-HPLC. All findings demonstrated that the home-made platform is advantageous at direct chemical analysis, as well as time-, solvent-, and material-savings, suggesting a robust tool for chemical fingerprinting of herbs.

  8. Determination of Alternaria mycotoxins in wine and juice using ionic liquid modified countercurrent chromatography as a pretreatment method followed by high-performance liquid chromatography.

    Science.gov (United States)

    Fan, Chen; Cao, Xueli; Liu, Man; Wang, Wei

    2016-03-04

    Alternariol (AOH), alternariol monomethyl ether (AME), and tenuazonic acid (TeA) are some of the main Alternaria mycotoxins that can be found as contaminants in food materials. The objective of this study was to develop a pretreatment method with countercurrent chromatography (CCC) for enrichment and cleanup of trace Alternaria mycotoxins in food samples prior to high-performance liquid chromatography (HPLC) analysis. An Analytical CCC instrument with a column volume 22.5mL was used, and a two-phase solvent system composed of ethyl acetate and water modified with 6% [HOOMIM][Cl] in mass to volume ratio was selected. Under the optimized CCC operation conditions, trace amounts of AOH, AME, and TeA in large volume of liquid sample were efficiently extracted and enriched in the stationary phase, and then eluted out just by reversing the stationary phase as mobile phase in the opposite flowing direction tail-to-head. The enrichment and elution strategies are unique and can be fulfilled online with high enrichment factors (87-114) and high recoveries (81.14-110.94%). The method has been successively applied to the determination of Alternaria mycotoxins in real apple juice and wine samples with the limits of detection (LOD) in the range of 0.03-0.14μgL(-1). Totally 12 wine samples and 15 apple juice samples from the local market were analyzed. The detection rate of AOH and AME in both kinds of the samples were more than 50%, while TeA was found in relatively high level of 1.75-49.61μgL(-1) in some of the apple juice samples. The proposed method is simple, rapid, and sensitive and could also be used for the analysis and monitoring of Alternaria mycotoxin in other food samples.

  9. [Qualitative and quantitative analysis of the amino acids in Rhizoma Arisaematis by ultra high performance liquid chromatography-tandem mass spectrometry and high performance liquid chromatography].

    Science.gov (United States)

    Wang, Xing; Chi, Yumei; Kang, An

    2014-12-01

    A method for the identification and determination of the polar amino components without ultraviolet activity in traditional Chinese medicines was developed. With Rhizoma Arisaematis as the object of this study, using pre-column derivatization with phenyl isothiocyanate (PITC) as the derivatization reagent, compounds were separated and identified on a C18 column (100 mm x 2.1 mm, 3.5 µm) by ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). A total of 20 components, including 18 amino acids and 2 amine compounds were identified. Furthermore, after the optimization of the derivatization conditions, 15 amino acids were determined by high performance liquid chromatography (HPLC) on Diamonsil C18 column (250 mm x 4.6 mm, 5 µm), detected at 254 nm and gradiently eluted by acetonitrile and 0. 05 mol/L ammonium acetate-acetic acid (pH 6. 5) as the mobile phases. The results of methodological study demonstrated that the method can meet the requirements of the determination. All calibration curves expressed good linearity: Glu, Try in the range of 2-100 mg/L, Arg in the range of 6-300 mg/L, others in the range of 0. 8-40 µg/L, with the correlation coefficients ≥ 0. 999 5. The average recovery of this method was among 95%-105% and the RSD was less than 3%. The developed method was successfully applied to quantitative determination of amino compounds in 12 batches of Rhizoma Arisaematis samples. The method is simple, sensitive, accurate, and can be used for rapid identification and determination of amino components in traditional Chinese medicines.

  10. A novel extraction technique based on carbon nanotubes reinforced hollow fiber solid/liquid microextraction for the measurement of piroxicam and diclofenac combined with high performance liquid chromatography.

    Science.gov (United States)

    Song, Xin-Yue; Shi, Yan-Ping; Chen, Juan

    2012-10-15

    A novel design of carbon nanotubes reinforced hollow fiber solid/liquid phase microextraction (CNTs-HF-SLPME) was developed to determine piroxicam and diclofenac in different real water samples. Functionalized multi-walled carbon nanotubes (MWCNTs) were held in the pores of hollow fiber with sol-gel technology. The pores and lumen of carbon nanotubes reinforced hollow fiber were subsequently filled with a μL volume of organic solvent (1-octanol), and then the whole assembly was used for the extraction of the target analytes in direct immersion sampling mode. The target analytes were extracted from the sample by two extractants, one of which is organic solvent placed inside the pores and lumen of hollow fiber and the other one is CNTs held in the pores of hollow fiber. After extraction, the analytes were desorbed in acetonitrile and analyzed using high performance liquid chromatography. This novel extraction mode showed more excellent extraction performance in comparison with conventional hollow fiber liquid microextraction (without adding CNTs) and carbon nanotubes reinforced hollow fiber solid microextraction (CNTs held in the pores of hollow fiber, but no organic solvents placed inside the lumen of hollow fiber) under the respective optimum conditions. This method provided 47- and 184-fold enrichment factors for piroxicam and diclofenac, respectively, good inter-fiber repeatability and batch-to-batch reproducibility. Linearity was observed in the range of 20-960 μg L(-1) for piroxicam, and 10-2560 μg L(-1) for diclofenac, with correlation coefficients of 0.9985 and 0.9989, respectively. The limits of detection were 4.58 μg L(-1) for piroxicam and 0.40 μg L(-1) for diclofenac.

  11. Salt-assisted dispersive liquid-liquid microextraction coupled with programmed temperature vaporization gas chromatography-mass spectrometry for the determination of haloacetonitriles in drinking water.

    Science.gov (United States)

    Ma, Huilian; Li, Yun; Zhang, Haijun; Shah, Syed Mazhar; Chen, Jiping

    2014-09-01

    We report here a new analytical method for the simultaneous determination of seven haloacetonitriles (HANs) in drinking water by coupling salt-assisted dispersive liquid-liquid microextraction (SADLLME) with programmed temperature vaporizer-gas chromatography-mass spectrometry (PTV-GC-MS). The newly developed method involves the dispersion of the extractant in aqueous sample by addition of a few grams of salt and no dispersion liquid was required as compared to the traditional DLLME methods. The extractant (CH2Cl2, 50μL) and the salt (Na2SO4, 2.4g) were successively added to water (8mL) in a conical centrifuge tube that was shaken for 1min and centrifuged (3500rpm, 3min). The aliquot of sedimented phase (4μL) was then directly injected into the PTV-GC-MS system. The limits of detection and quantification for the HANs were 0.4-13.2ngL(-1) and 1.2-43.9ngL(-1), respectively. The calibration curves showed good linearity (r(2)≥0.9904) over 3 orders of magnitude. The repeatability of the method was investigated by evaluating the intra- and inter-day precisions. The relative standard deviations (RSDs) obtained were lower than 10.2% and 7.8% at low and high concentration levels. The relative recoveries ranged from 79.3% to 105.1%. The developed methodology was applied for the analysis of seven HANs in several drinking water samples in coastal and inland cities of China. It was demonstrated to be a simple, sensible, reproducible and environment friendly method for the determination of trace HANs in drinking water samples.

  12. Toxicological determination and in vitro metabolism of the designer drug methylenedioxypyrovalerone (MDPV) by gas chromatography/mass spectrometry and liquid chromatography/quadrupole time-of-flight mass spectrometry.

    Science.gov (United States)

    Strano-Rossi, Sabina; Cadwallader, Amy B; de la Torre, Xavier; Botrè, Francesco

    2010-09-01

    A method for the toxicological screening of the new designer drug methylenedioxypyrovalerone (MDPV) is described; with an emphasis on its application for anti-doping analysis. The metabolism of MDPV was evaluated in vitro using human liver microsomes and S9 cellular fractions for CYP450 phase I and uridine 5'-diphosphoglucuronosyltransferase (UGT) and sulfotransferase (SULT) phase II metabolism studies. The resulting metabolites were subsequently liquid/liquid extracted and analyzed using gas chromatography/mass spectrometry (GC/MS) as trimethylsilyl (TMS) derivatives. The structures of the metabolites were further confirmed by accurate mass measurement using a liquid chromatography/quadrupole time-of-flight (LC/QTOF) mass spectrometer. The studies demonstrated that the main metabolites of MDPV are catechol and methyl catechol pyrovalerone, which are in turn sulfated and glucuronated. The method for the determination of MDPV in urine has been fully validated by assessing the limits of detection and quantification, linearity, repeatability, and accuracy. This validation demonstrates the suitability for screening of this stimulant substance for anti-doping and forensic toxicology purposes. 2010 John Wiley & Sons, Ltd.

  13. Improved sensitivity gas chromatography-mass spectrometry determination of parabens in waters using ionic liquids.

    Science.gov (United States)

    Cacho, Juan Ignacio; Campillo, Natalia; Viñas, Pilar; Hernández-Córdoba, Manuel

    2016-01-01

    A new procedure for the introduction of ionic liquid samples in gas chromatography (GC) is proposed. This procedure, based on microvial insert thermal desorption, allows the direct analysis of the compounds preconcentrated by ionic liquid based liquid-liquid microextraction (IL-LLME) using the combination of a thermal desorption unit (TDU) and a programmed temperature vaporization injector (PTV). Two different IL-LLME methodologies, one based on the formation of a microdroplet emulsion by dispersive liquid-liquid microextraction (DLLME) and other through ultrasound-assisted emulsification microextraction (USAEME) were studied and evaluated. IL-DLLME proved advantageous and consequently, it was adopted for preconcentration purposes. This easy to apply approach was used for the determination of five parabens (methyl-, ethyl-, propyl-, butyl- and isobutyl paraben) in swimming pool waters, after in situ acetylation. The optimized conditions of TDU/PTV allowed the analytes contained in 20 µL of the enriched IL to be transferred to the capillary column. Quantification of the samples was carried out against aqueous standards, and quantification limits of between 4.3 and 8.1 ng L(-1) were obtained, depending on the compound. Concentrations of between 9 and 47 ng L(-1) for some analytes were obtained in the analysis of ten samples.

  14. Ultrapreconcentration and determination of organophosphorus pesticides in water by solid-phase extraction combined with dispersive liquid-liquid microextraction and high-performance liquid chromatography.

    Science.gov (United States)

    Chen, Junhua; Zhou, Guangming; Deng, Yongli; Cheng, Hongmei; Shen, Jie; Gao, Yi; Peng, Guilong

    2016-01-01

    Solid-phase extraction coupled with dispersive liquid-liquid microextraction was developed as an ultra-preconcentration method for the determination of four organophosphorus pesticides (isocarbophos, parathion-methyl, triazophos and fenitrothion) in water samples. The analytes considered in this study were rapidly extracted and concentrated from large volumes of aqueous solutions (100 mL) by solid-phase extraction coupled with dispersive liquid-liquid microextraction and then analyzed using high performance liquid chromatography. Experimental variables including type and volume of elution solvent, volume and flow rate of sample solution, salt concentration, type and volume of extraction solvent and sample solution pH were investigated for the solid-phase extraction coupled with dispersive liquid-liquid microextraction with these analytes, and the best results were obtained using methanol as eluent and ethylene chloride as extraction solvent. Under the optimal conditions, an exhaustive extraction for four analytes (recoveries >86.9%) and high enrichment factors were attained. The limits of detection were between 0.021 and 0.15 μg/L. The relative standard deviations for 0.5 μg/L of the pesticides in water were in the range of 1.9-6.8% (n = 5). The proposed strategy offered the advantages of simple operation, high enrichment factor and sensitivity and was successfully applied to the determination of four organophosphorus pesticides in water samples.

  15. Identification of novel circulating coffee metabolites in human plasma by liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Redeuil, Karine; Smarrito-Menozzi, Candice; Guy, Philippe; Rezzi, Serge; Dionisi, Fabiola; Williamson, Gary; Nagy, Kornél; Renouf, Mathieu

    2011-07-22

    This study reports a liquid chromatography-mass spectrometry method for the detection of polyphenol-derived metabolites in human plasma without enzymatic treatment after coffee consumption. Separation of available standards was achieved by reversed-phase ultra performance liquid chromatography and detection was performed by high resolution mass spectrometry in negative electrospray ionization mode. This analytical method was then applied for the identification and relative quantification of circulating coffee metabolites. A total of 34 coffee metabolites (mainly reduced, sulfated and methylated forms of caffeic acid, coumaric acid, caffeoylquinic acid and caffeoylquinic acid lactone) were identified based on mass accuracy (<4 ppm for most metabolites), specific fragmentation pattern and co-chromatography (when standard available). Among them, 19 circulating coffee metabolites were identified for the first time in human plasma such as feruloylquinic acid lactone, sulfated and glucuronidated forms of feruloylquinic acid lactone and sulfated forms of coumaric acid. Phenolic acid derivatives such as dihydroferulic acid, dihydroferulic acid 4'-O-sulfate, caffeic acid 3'-O-sulfate, dimethoxycinnamic acid, dihydrocaffeic acid and coumaric acid O-sulfate appeared to be the main metabolites circulating in human plasma after coffee consumption. The described method is a sensitive and reliable approach for the identification of coffee metabolites in biological fluids. In future, this analytical method will give more confidence in compound identification to provide a more comprehensive assessment of coffee polyphenol bioavailability studies in humans.

  16. Determination of eight fluoroquinolones in groundwater samples with ultrasound-assisted ionic liquid dispersive liquid-liquid microextraction prior to high-performance liquid chromatography and fluorescence detection.

    Science.gov (United States)

    Vázquez, M M Parrilla; Vázquez, P Parrilla; Galera, M Martínez; García, M D Gil

    2012-10-20

    An ultrasound-assisted ionic liquid dispersive liquid-liquid microextraction (US-IL-DLLME) procedure was developed for the extraction of eight fluoroquinolones (marbofloxacin, norfloxacin, ciprofloxacin, lomefloxacin, danofloxacin, enrofloxacin, oxolinic acid and nalidixic acid) in groundwater, using high-performance liquid chromatography with fluorescence detection (HPLC-FD). The ultrasound-assisted process was applied to accelerate the formation of the fine cloudy solution using a small volume of disperser solvent (0.4 mL of methanol), which increased the extraction efficiency and reduced the equilibrium time. For the DLLME procedure, the IL 1-octyl-3-methylimidazolium hexafluorophosphate ([C(8)MIM] [PF(6)]) and methanol (MeOH) were used as extraction and disperser solvent, respectively. By comparing [C(8)MIM] [PF(6)] with 1-hexyl-3-methylimidazolium hexafluorophosphate ([C(6)MIM] [PF(6)]) and 1-butyl-3-methylimidazolium hexafluorophosphate ([C(4)MIM] [PF(6)]) as extraction solvents, it was observed that when using [C(8)MIM] [PF(6)] the cloudy solution was formed more readily than when using [C(6)MIM] [PF(6)] or [C(4)MIM] [PF(6)]. The factors affecting the extraction efficiency, such as the type and volume of ionic liquid, type and volume of disperser solvent, cooling in ice-water, sonication time, centrifuging time, sample pH and ionic strength, were optimised. A slight increase in the recoveries of fluoroquinolones was observed when an ice-water bath extraction step was included in the analytical procedure (85-107%) compared to those obtained without this step (83-96%). Under the optimum conditions, linearity of the method was observed over the range 10-300 ng L(-1) with correlation coefficient >0.9981. The proposed method has been found to have excellent sensitivity with limit of detection between 0.8 and 13 ng L(-1) and precision with relative standard deviation values between 4.8 and 9.4% (RSD, n=5). Good enrichment factors (122-205) and recoveries (85

  17. Arabidopsis thaliana Polar Glycerolipid Profiling by Thin Layer Chromatography (TLC) Coupled with Gas-Liquid Chromatography (GLC)

    Science.gov (United States)

    Wang, Zhen; Benning, Christoph

    2011-01-01

    Biological membranes separate cells from the environment. From a single cell to multicellular plants and animals, glycerolipids, such as phosphatidylcholine or phosphatidylethanolamine, form bilayer membranes which act as both boundaries and interfaces for chemical exchange between cells and their surroundings. Unlike animals, plant cells have a special organelle for photosynthesis, the chloroplast. The intricate membrane system of the chloroplast contains unique glycerolipids, namely glycolipids lacking phosphorus: monogalactosyldiacylglycerol (MGDG), digalactosyldiacylglycerol (DGDG), sulfoquinovosyldiacylglycerol (SQDG)4. The roles of these lipids are beyond simply structural. These glycolipids and other glycerolipids were found in the crystal structures of photosystem I and II indicating the involvement of glycerolipids in photosynthesis8,11. During phosphate starvation, DGDG is transferred to extraplastidic membranes to compensate the loss of phospholipids9,12. Much of our knowledge of the biosynthesis and function of these lipids has been derived from a combination of genetic and biochemical studies with Arabidopsis thaliana14. During these studies, a simple procedure for the analysis of polar lipids has been essential for the screening and analysis of lipid mutants and will be outlined in detail. A leaf lipid extract is first separated by thin layer chromatography (TLC) and glycerolipids are stained reversibly with iodine vapor. The individual lipids are scraped from the TLC plate and converted to fatty acyl methylesters (FAMEs), which are analyzed by gas-liquid chromatography coupled with flame ionization detection (FID-GLC) (Figure 1). This method has been proven to be a reliable tool for mutant screening. For example, the tgd1,2,3,4 endoplasmic reticulum-to-plastid lipid trafficking mutants were discovered based on the accumulation of an abnormal galactoglycerolipid: trigalactosyldiacylglycerol (TGDG) and a decrease in the relative amount of 18:3 (carbons

  18. Preparative Isolation and Purification of Flavone C-Glycosides from the Leaves of Ficus microcarpa L. f by Medium-Pressure Liquid Chromatography, High-Speed Countercurrent Chromatography, and Preparative Liquid Chromatography.

    Science.gov (United States)

    Wang, Xiaohong; Liang, Yong; Zhu, Licai; Xie, Huichun; Li, Hang; He, Junting; Pan, Man; Zhang, Tianyou; Ito, Yoichiro

    2010-01-01

    Combined with medium-pressure liquid chromatography (MPLC) and preparative high-performance liquid chromatography (perp-HPLC), high-speed countercurrent chromatography (HSCCC) was applied for separation and purification of flavone C-glycosides from the crude extract of leaves of Ficus microcarpae L. f. HSCCC separation was performed on a two-phase solvent system composed of methyl tert- butyl ether - ethyl acetate - 1-butanol - acetonitrile - 0.1% aqueous trifluoroacetic acid at a volume ratio of 1:3:1:1:5. Partially resolved peak fractions from HSCCC separation were further purified by preparative HPLC. Four well-separated compounds were obtained and their purities were determined by HPLC. The purities of these peaks were 97.28%, 97.20%, 92.23%, and 98.40%.. These peaks were characterized by ESI-MS(n). According to the reference, they were identified as orientin (peak I), isovitexin-3″-O-glucopyranoside (peak II), isovitexin (peak III), and vitexin (peak IV), yielded 1.2 mg, 4.5 mg, 3.3 mg, and 1.8 mg, respectively.

  19. Development and validation of a liquid chromatography-tandem mass spectrometry method for the simultaneous determination of nine corticosteroid residues in bovine liver samples

    Energy Technology Data Exchange (ETDEWEB)

    Dusi, Guglielmo, E-mail: guglielmo.dusi@izsler.it [Istituto Zooprofilattico Sperimentale della Lombardia e dell' Emilia Romagna, ' B. Ubertini' , Via Bianchi 9, 25124 Brescia (Italy); Gasparini, Mara; Curatolo, Michele; Assini, Walter; Bozzoni, Eros; Tognoli, Nadia; Ferretti, Enrica [Istituto Zooprofilattico Sperimentale della Lombardia e dell' Emilia Romagna, ' B. Ubertini' , Via Bianchi 9, 25124 Brescia (Italy)

    2011-08-26

    A liquid chromatography tandem mass spectrometry (LC-MS/MS) confirmatory method for the simultaneous determination of nine corticosteroids in liver, including the four MRL compounds listed in Council Regulation 37/2010, was developed. After an enzymatic deconjugation and a solvent extraction of the liver tissue, the resulting solution was cleaned up through an SPE Oasis HLB cartridge. The analytes were then detected by liquid chromatography-negative-ion electrospray tandem mass spectrometry, using deuterium-labelled internal standards. The procedure was validated as a quantitative confirmatory method according to the Commission Decision 2002/657/EC criteria. The results showed that the method was suitable for statutory residue testing regarding the following performance characteristics: instrumental linearity, specificity, precision (repeatability and intra-laboratory reproducibility), recovery, decision limit (CC{alpha}), detection capability (CC{beta}) and ruggedness. All the corticosteroids can be detected at a concentration around 1 {mu}g kg{sup -1}; the recoveries were above 62% for all the analytes. Repeatability and reproducibility (within-laboratory reproducibility) for all the analytes were below 7.65% and 15.5%, respectively.

  20. Ultrafiltration liquid chromatography combined with high-speed countercurrent chromatography for screening and isolating potential α-glucosidase and xanthine oxidase inhibitors from Cortex Phellodendri.

    Science.gov (United States)

    Li, Sainan; Liu, Chunming; Guo, Liping; Zhang, Yuchi; Wang, Jing; Ma, Bing; Wang, Yueqi; Wang, Yumeng; Ren, Junqi; Yang, Xiaojing; Qin, Yao; Tang, Ying

    2014-09-01

    Cortex Phellodendri is a typical Chinese herb with a large number of alkaloids existing in all parts of it. The most common methods for screening and isolating alkaloids are mostly labor intensive and time consuming. In this study, a new assay based upon ultrafiltration liquid chromatography was developed for the rapid screening of ligands for α-glucosidase and xanthine oxidase. The C. Phellodendri extract was found to contain two alkaloids with both α-glucosidase- and xanthine oxidase binding activities and one lactone with α-glucosidase-binding activity. Subsequently, with the help of high-speed countercurrent chromatography, the specific binding ligands including palmatine, berberine, and obaculactone with purities of 97.38, 96.12, and 96.08%, respectively, were successfully separated. An optimized low-toxicity two-phase solvent system composed of ethyl acetate/n-butanol/ethanol/water (3.5:1.7:0.5:5, v/v/v/v) was used to isolate the three compounds mentioned above from C. Phellodendri. The targeted compounds were identified by liquid chromatography coupled with mass spectrometry and NMR spectroscopy. Therefore, ultrafiltration liquid chromatography combined with high-speed countercurrent chromatography is not only a powerful tool for screening and isolating α-glucosidase and xanthine oxidase inhibitors in complex samples but is also a useful platform for discovering bioactive compounds for the prevention and treatment of diabetes mellitus and gout.

  1. Dual ultrasonic-assisted dispersive liquid-liquid microextraction coupled with microwave-assisted derivatization for simultaneous determination of 20(S)-protopanaxadiol and 20(S)-protopanaxatriol by ultra high performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Zhao, Xian-En; Lv, Tao; Zhu, Shuyun; Qu, Fei; Chen, Guang; He, Yongrui; Wei, Na; Li, Guoliang; Xia, Lian; Sun, Zhiwei; Zhang, Shijuan; You, Jinmao; Liu, Shu; Liu, Zhiqiang; Sun, Jing; Liu, Shuying

    2016-03-11

    This paper, for the first time, reported a speedy hyphenated technique of low toxic dual ultrasonic-assisted dispersive liquid-liquid microextraction (dual-UADLLME) coupled with microwave-assisted derivatization (MAD) for the simultaneous determination of 20(S)-protopanaxadiol (PPD) and 20(S)-protopanaxatriol (PPT). The developed method was based on ultra high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) detection using multiple-reaction monitoring (MRM) mode. A mass spectrometry sensitizing reagent, 4'-carboxy-substituted rosamine (CSR) with high reaction activity and ionization efficiency was synthesized and firstly used as derivatization reagent. Parameters of dual-UADLLME, MAD and UHPLC-MS/MS conditions were all optimized in detail. Low toxic brominated solvents were used as extractant instead of traditional chlorinated solvents. Satisfactory linearity, recovery, repeatability, accuracy and precision, absence of matrix effect and extremely low limits of detection (LODs, 0.010 and 0.015ng/mL for PPD and PPT, respectively) were achieved. The main advantages were rapid, sensitive and environmentally friendly, and exhibited high selectivity, accuracy and good matrix effect results. The proposed method was successfully applied to pharmacokinetics of PPD and PPT in rat plasma.

  2. High-throughput method for macrolides and lincosamides antibiotics residues analysis in milk and muscle using a simple liquid-liquid extraction technique and liquid chromatography-electrospray-tandem mass spectrometry analysis (LC-MS/MS).

    Science.gov (United States)

    Jank, Louise; Martins, Magda Targa; Arsand, Juliana Bazzan; Campos Motta, Tanara Magalhães; Hoff, Rodrigo Barcellos; Barreto, Fabiano; Pizzolato, Tânia Mara

    2015-11-01

    A fast and simple method for residue analysis of the antibiotics classes of macrolides (erythromycin, azithromycin, tylosin, tilmicosin and spiramycin) and lincosamides (lincomycin and clindamycin) was developed and validated for cattle, swine and chicken muscle and for bovine milk. Sample preparation consists in a liquid-liquid extraction (LLE) with acetonitrile, followed by liquid chromatography-electrospray-tandem mass spectrometry analysis (LC-ESI-MS/MS), without the need of any additional clean-up steps. Chromatographic separation was achieved using a C18 column and a mobile phase composed by acidified acetonitrile and water. The method was fully validated according the criteria of the Commission Decision 2002/657/EC. Validation parameters such as limit of detection, limit of quantification, linearity, accuracy, repeatability, specificity, reproducibility, decision limit (CCα) and detection capability (CCβ) were evaluated. All calculated values met the established criteria. Reproducibility values, expressed as coefficient of variation, were all lower than 19.1%. Recoveries range from 60% to 107%. Limits of detection were from 5 to 25 µg kg(-1).The present method is able to be applied in routine analysis, with adequate time of analysis, low cost and a simple sample preparation protocol.

  3. Quantification of clenbuterol at trace level in human urine by ultra-high pressure liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Nicoli, Raul; Petrou, Michael; Badoud, Flavia; Dvorak, Jiri; Saugy, Martial; Baume, Norbert

    2013-05-31

    Clenbuterol is a β2 agonist agent with anabolic properties given by the increase in the muscular mass in parallel to the decrease of the body fat. For this reason, the use of clenbuterol is forbidden by the World Anti-Doping Agency (WADA) in the practice of sport. This compound is of particular interest for anti-doping authorities and WADA-accredited laboratories due to the recent reporting of risk of unintentional doping following the eating of meat contaminated with traces of clenbuterol in some countries. In this work, the development and the validation of an ultra-high pressure liquid chromatography coupled to electrospray ionization tandem mass spectrometry (UHPLC-ESI-MS/MS) method for the quantification of clenbuterol in human urine is described. The analyte was extracted from urine samples by liquid-liquid extraction (LLE) in basic conditions using tert butyl-methyl ether (TBME) and analyzed by UHPLC-MS/MS with a linear gradient of acetonitrile in 9min only. The simple and rapid method presented here was validated in compliance with authority guidelines and showed a limit of quantification at 5pg/mL and a linearity range from 5pg/mL to 300pg/mL. Good trueness (85.8-105%), repeatability (5.7-10.6% RSD) and intermediate precision (5.9-14.9% RSD) results were obtained. The method was then applied to real samples from eighteen volunteers collecting urines after single oral doses administration (1, 5 and 10μg) of clenbuterol-enriched yogurts.

  4. Analysis of allergens in tubeimu saponin extracts by using rat basophilic leukemia 2H3 cell-based affinity chromatography coupled to liquid chromatography and mass spectrometry.

    Science.gov (United States)

    Zhang, Tao; Han, Shengli; Liu, Qi; Guo, Ying; He, Langchong

    2014-11-01

    An affinity two-dimensional chromatography method was developed for the recognition, separation, and identification of allergic components from tubeimu saponin extracts, a preparation often injected to treat various conditions as indicated by traditional Chinese medicine. Rat basophilic leukemia-2H3 cell membranes were used as the stationary phase of a membrane affinity chromatography column to capture components with affinity for mast cells that could be involved in a degranulation reaction. The retained components were enriched and analyzed by membrane affinity chromatography with liquid chromatography and mass spectrometry via a port switch valve. Suitability and reliability of the method was investigated using appropriate standards, and then, the method was applied to identify components retained from tubeimu saponin extracts. Tubeimoside A was identified in this way as a potential allergen, and degranulation assays confirmed that tubeimoside A induces RBL-2H3 cell degranulation in a dose-dependent manner. An increase in Ca(2+) influx indicated that degranulation induced by tubeimoside A is likely Ca(2+) dependent. Coupled with the degranulation assay, RBL-2H3 cell-based affinity chromatography coupled with liquid chromatography and mass spectrometry is an effective method for screening and identifying allergic components from tubeimu saponin extracts.

  5. Polymeric imidazolium ionic liquids as valuable stationary phases in gas chromatography: chemical synthesis and full characterization.

    Science.gov (United States)

    González-Álvarez, Jaime; Blanco-Gomis, Domingo; Arias-Abrodo, Pilar; Díaz-Llorente, Daniel; Ríos-Lombardía, Nicolás; Busto, Eduardo; Gotor-Fernández, Vicente; Gutiérrez-Álvarez, María Dolores

    2012-04-06

    Seven new functionalized polymerizable ionic liquids were chemically prepared, and later applied for the preparation of polymeric stationary phases in gas chromatography. These coated GC columns, which exhibited good thermal stabilities (240-300°C) and very high efficiencies (3120-4200 plates/m), have been characterized using the Abraham solvation parameter model. The chromatographic behavior of these polymeric IL columns has been deeply studied observing excellent selectivities in the separation of many organic substances such as alkanes, ketones, alcohols, amines or esters in mixtures of polar and non polar solvents or fragrances. Remarkably, the challenging separation of xylene isomers has been possible using a bis(trifluoromethylsulfonyl)amide based imidazolium IL coated column as a gas chromatography stationary phase.

  6. Reproducibility of retention time and peak area in comprehensive two-dimensional liquid chromatography.

    Science.gov (United States)

    Elsner, Victoria; Wulf, Volker; Wirtz, Michaela; Schmitz, Oliver J

    2015-01-01

    Comprehensive two-dimensional liquid chromatography is used to separate anionic, nonionic, and amphoteric surfactants by substance class, alkyl chain distribution, and degree of ethoxylation. A nearly orthogonal system with a hydrophilic interaction chromatography (HILIC) phase in the first and a reversed-phase material in the second dimension is applied to generate a separation with maximum peak capacity. The potential of the developed method is demonstrated by the reproducibility of retention time and peak area, which shows standard deviations less than 5 % and the analysis of real samples. An external calibration and the standard addition method were applied to determine unknown concentrations for the alkyl chain homologues of a betaine and for one ethoxylate (EO) homologue of a fatty alcohol ethoxylate in a sample mixture.

  7. Low Density Solvent-Based Dispersive Liquid-Liquid Microextraction for the Determination of Synthetic Antioxidants in Beverages by High-Performance Liquid Chromatography

    Science.gov (United States)

    Çabuk, Hasan; Köktürk, Mustafa

    2013-01-01

    A simple and efficient method was established for the determination of synthetic antioxidants in beverages by using dispersive liquid-liquid microextraction combined with high-performance liquid chromatography with ultraviolet detection. Butylated hydroxy toluene, butylated hydroxy anisole, and tert-butylhydroquinone were the antioxidants evaluated. Experimental parameters including extraction solvent, dispersive solvent, pH of sample solution, salt concentration, and extraction time were optimized. Under optimal conditions, the extraction recoveries ranged from 53 to 96%. Good linearity was observed by the square of correlation coefficients ranging from 0.9975 to 0.9997. The relative standard deviations ranged from 1.0 to 5.2% for all of the analytes. Limits of detection ranged from 0.85 to 2.73 ng mL−1. The method was successfully applied for determination of synthetic antioxidants in undiluted beverage samples with satisfactory recoveries. PMID:23853535

  8. Low density solvent-based dispersive liquid-liquid microextraction for the determination of synthetic antioxidants in beverages by high-performance liquid chromatography.

    Science.gov (United States)

    Çabuk, Hasan; Köktürk, Mustafa

    2013-01-01

    A simple and efficient method was established for the determination of synthetic antioxidants in beverages by using dispersive liquid-liquid microextraction combined with high-performance liquid chromatography with ultraviolet detection. Butylated hydroxy toluene, butylated hydroxy anisole, and tert-butylhydroquinone were the antioxidants evaluated. Experimental parameters including extraction solvent, dispersive solvent, pH of sample solution, salt concentration, and extraction time were optimized. Under optimal conditions, the extraction recoveries ranged from 53 to 96%. Good linearity was observed by the square of correlation coefficients ranging from 0.9975 to 0.9997. The relative standard deviations ranged from 1.0 to 5.2% for all of the analytes. Limits of detection ranged from 0.85 to 2.73 ng mL(-1). The method was successfully applied for determination of synthetic antioxidants in undiluted beverage samples with satisfactory recoveries.

  9. Analysis of potential migrants from plastic materials in milk by liquid chromatography-mass spectrometry with liquid-liquid extraction and low-temperature purification.

    Science.gov (United States)

    Bodai, Zsolt; Szabó, Bálint Sámuel; Novák, Márton; Hámori, Susanne; Nyiri, Zoltán; Rikker, Tamás; Eke, Zsuzsanna

    2014-10-15

    A simple and fast analytical method was developed for the determination of six UV stabilizers (Cyasorb UV-1164, Tinuvin P, Tinuvin 234, Tinuvin 326, Tinuvin 327, and Tinuvin 1577) and five antioxidants (Irgafos 168, Irganox 1010, Irganox 3114, Irganox 3790, and Irganox 565) in milk. For sample preparation liquid-liquid extraction with low-temperature purification combined with centrifugation was used to remove fats, proteins, and sugars. After the cleanup step, the sample was analyzed with high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS). External standard and matrix calibrations were tested. External calibration proved to be acceptable for Tinuvin P, Tinuvin 234, Tinuvin 326, Tinuvin 327, Irganox 3114, and Irganox 3790. The method was successfully validated with matrix calibration for all compounds. Method detection limits were between 0.25 and 10 μg/kg. Accuracies ranged from 93 to 109%, and intraday precisions were <13%.

  10. Determination of spirocyclic tetronic/tetramic acid derivatives and neonicotinoid insecticides in fruits and vegetables by liquid chromatography and mass spectrometry after dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Pastor-Belda, Marta; Garrido, Isabel; Campillo, Natalia; Viñas, Pilar; Hellín, Pilar; Flores, Pilar; Fenoll, José

    2016-07-01

    Dispersive liquid-liquid microextraction was used to preconcentrate three spirocyclic tetronic/tetramic acid derivatives (spirotetramat, spiromesifen and spirodiclofen) and five neonicotinoid (thiamethoxam, chlotianidin, imidacloprid, acetamiprid and thiacloprid) insecticides previously extracted from fruit and vegetable matrices with acetonitrile. The organic enriched phase was evaporated, reconstituted in 25μL acetonitrile and analyzed by reversed-phase liquid chromatography with tandem mass spectrometry using a triple quadrupole in selected reaction monitoring mode. Enrichment factors in the 15-100 range were obtained. A matrix effect was observed, the detection limits varying between 0.025 and 0.5ngg(-1), depending on the compound and the sample matrix. The developed method was applied to the analysis of 25 samples corresponding to five different fruit and vegetable matrices. Only thiamethoxam was detected in a lemon sample at a concentration close to the quantification limit, and spiromesifen and spirotetramat at concentrations between 11.6 and 54.5ngg(-1).

  11. Analysis of recombinant Schistosoma mansoni antigen rSmp28 by on-line liquid chromatography-mass spectrometry combined with sodium dodecyl sulfate polyacrylamide gel electrophoresis

    NARCIS (Netherlands)

    Klarskov, K.; Roecklin, D.; Bouchon, B.; Sabatie, J.; Van Dorsselaer, A.; Bischoff, Rainer

    1994-01-01

    A recombinant Schistosoma mansoni antigen produced in Saccharomyces cerevisiae and purified by glutathione-Sepharose affinity chromatography was analyzed by tryptic peptide mapping using on-line reversed-phase high-performance liquid chromatography pneumatically assisted electrospray mass

  12. Determination of three estrogens and bisphenol A by functional ionic liquid dispersive liquid-phase microextraction coupled with ultra-high performance liquid chromatography and ultraviolet detection.

    Science.gov (United States)

    Jiang, Yuehuang; Tang, Tingting; Cao, Zhen; Shi, Guoyue; Zhou, Tianshu

    2015-06-01

    A hydroxyl-functionalized ionic liquid, 1-hydroxyethyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide, was employed in an improved dispersive liquid-phase microextraction method coupled with ultra high performance liquid chromatography for the enrichment and determination of three estrogens and bisphenol A in environmental water samples. The introduced hydroxyl group acted as the H-bond acceptor that dispersed the ionic liquid effectively in the aqueous phase without dispersive solvent or external force. Fourier transform infrared spectroscopy indicated that the hydroxyl group of the cation of the ionic liquid enhanced the combination of extractant and analytes through the formation of hydrogen bonds. The improvement of the extraction efficiency compared with that with the use of alkyl ionic liquid was proved by a comparison study. The main parameters including volume of extractant, temperature, pH, and extraction time were investigated. The calibration curves were linear in the range of 5.0-1000 μg/L for estrone, estradiol, and bisphenol A, and 10.0-1000 μg/L for estriol. The detection limits were in the range of 1.7-3.4 μg/L. The extraction efficiency was evaluated by enrichment factor that were between 85 and 129. The proposed method was proved to be simple, low cost, and environmentally friendly for the determination of the four endocrine disruptors in environmental water samples.

  13. Study of surface-bonded dicationic ionic liquids as stationary phases for hydrophilic interaction chromatography.

    Science.gov (United States)

    Qiao, Lizhen; Li, Hua; Shan, Yuanhong; Wang, Shuangyuan; Shi, Xianzhe; Lu, Xin; Xu, Guowang

    2014-02-21

    In the present study, several geminal dicationic ionic liquids based on 1,4-bis(3-allylimidazolium)butane and 1,8-bis(3-allylimidazolium)octane in combination with different anions bromide and bis(trifluoromethanesulphonyl)imide were prepared and then bonded to the surface of 3-mercaptopropyl modified silica materials through the "thiol-ene" click chemistry as stationary phases for hydrophilic interaction chromatography (HILIC). Compared with their monocationic analogues, the dicationic ionic liquids stationary phases presented effective retention and good selectivity for typical hydrophilic compounds under HILIC mode with the column efficiency as high as 130,000 plates/m. Moreover, the influence of different alkyl chain spacer between dications and combined anions on the retention behavior and selectivity of the dicationic ionic liquids stationary phases under HILIC mode was displayed. The results indicated that the longer linkage chain would decrease the hydrophilicity and retention on the dicationic ionic liquid stationary phase, and while differently combined anions had no difference due to the exchangeability under the common HILIC mobile phase with buffer salt. Finally, the retention mechanism was investigated by evaluating the effect of chromatographic factors on retention, including the water content in the mobile phase, the mobile phase pH and buffer salt concentration. The results showed that the dicationic ionic liquids stationary phases presented a mixed-mode retention behavior with HILIC mechanism and anion exchange.

  14. Characterization of rhamnolipids by liquid chromatography/mass spectrometry after solid-phase extraction.

    Science.gov (United States)

    Behrens, Beate; Engelen, Jeannine; Tiso, Till; Blank, Lars Mathias; Hayen, Heiko

    2016-04-01

    Rhamnolipids are surface-active agents with a broad application potential that are produced in complex mixtures by bacteria of the genus Pseudomonas. Analysis from fermentation broth is often characterized by laborious sample preparation and requires hyphenated analytical techniques like liquid chromatography coupled to mass spectrometry (LC-MS) to obtain detailed information about sample composition. In this study, an analytical procedure based on chromatographic method development and characterization of rhamnolipid sample material by LC-MS as well as a comparison of two sample preparation methods, i.e., liquid-liquid extraction and solid-phase extraction, is presented. Efficient separation was achieved under reversed-phase conditions using a mixed propylphenyl and octadecylsilyl-modified silica gel stationary phase. LC-MS/MS analysis of a supernatant from Pseudomonas putida strain KT2440 pVLT33_rhlABC grown on glucose as sole carbon source and purified by solid-phase extraction revealed a total of 20 congeners of di-rhamnolipids, mono-rhamnolipids, and their biosynthetic precursors 3-(3-hydroxyalkanoyloxy)alkanoic acids (HAAs) with different carbon chain lengths from C8 to C14, including three rhamnolipids with uncommon C9 and C11 fatty acid residues. LC-MS and the orcinol assay were used to evaluate the developed solid-phase extraction method in comparison with the established liquid-liquid extraction. Solid-phase extraction exhibited higher yields and reproducibility as well as lower experimental effort.

  15. [Diagnosis of anaerobic infection of the pleural fluid using gas-liquid chromatography].

    Science.gov (United States)

    Alvarez, M; Rojo, P; Latorre, M; Herrero, O; Arriaga, I; Merino, J M; Cisterna, R

    1993-02-01

    An assessment of the efficacy of the detection of volatile and non-volatile fatty acids that are produced by microorganisms aimed at the possible diagnosis of pleural empyema. 106 pleural fluids were examined by gas-liquid chromatography in contrast to conventional aerobic and anaerobic cultures. The sample previously prepared (1 microliter) was injected in an Hewlett-Packard 5890 chromatograph, that was equipped with a fused silica capillary column and a flame ionization detector. Growth of aerobic or anaerobic microorganisms was obtained in 13 (12.3%) of the samples, and volatile or non-volatile fatty acids were detected in all of them (sensitivity = 1). No growth was obtained in the 93 samples, but volatile or non-volatile fatty acids were detected in 64 (68.8%) of them (specificity = 0.31). A positive predictive value of 0.17 and a negative predictive value of 1 were obtained. Growth of anaerobic microorganisms was obtained in 9 samples (8.5%) and volatile fatty acids were detected in all of them (sensitivity = 1). Anaerobic microorganisms did not grow in 97 samples, however volatile fatty acids were detected in 2 (2.1%) of them. A positive predictive value of 0.82 and a negative of 1 were obtained. Referring to pleural fluid samples, the detection of volatile and non-volatile fatty acids by gas-liquid chromatography is a highly sensitive method, that may be used to quickly reject negative samples in about 30 mins. Furthermore, when anaerobic microorganisms exist, the high specificity of gas-liquid chromatography will make it possible to confirm their presence in the sample, mainly if there is a clinical suspect of anaerobic infection. Thus, the utilization of this sensitive method may also change the therapeutic behaviour.

  16. Integration of electrochemistry with ultra-performance liquid chromatography/mass spectrometry.

    Science.gov (United States)

    Cai, Yi; Zheng, Qiuling; Liu, Yong; Helmy, Roy; Loo, Joseph A; Chen, Hao

    2015-01-01

    This study presents the development of ultra-performance liquid chromatography (UPLC) mass spectrometry (MS) combined with electrochemistry (EC) for the first time and its application for the structural analysis of proteins/peptides that contain disulfide bonds. In our approach, a protein/peptide mixture sample undergoes a fast UPLC separation and subsequent electrochemical reduction in an electrochemical flow cell followed by online MS and tandem mass spectrometry (MS/MS) analyses. The electrochemical cell is coupled to the mass spectrometer using our recently developed desorption electrospray ionization (DESI) interface. Using this UPLC/EC/DESI-MS method, peptides that contain disulfide bonds can be differentiated from those without disulfide bonds, as the former are electroactive and reducible. MS/MS analysis of the disulfide-reduced peptide ions provides increased information on the sequence and disulfide-linkage pattern. In a reactive DESI- MS detection experiment in which a supercharging reagent was used to dope the DESI spray solvent, increased charging was obtained for the UPLC-separated proteins. Strikingly, upon online electrolytic reduction, supercharged proteins (e.g., α-lactalbumin) showed even higher charging, which will be useful in top- down protein structure MS analysis as increased charges are known to promote protein ion dissociation. Also, the separation speed and sensitivity are enhanced by approximately 1(~)2 orders of magnitude by using UPLC for the liquid chromatography (LC)/EC/MS platform, in comparison to the previously used high- performance liquid chromatography (HPLC). This UPLC/EC/DESI-MS method combines the power of fast UPLC separation, fast electrochemical conversion, and online MS structural analysis for a potentially valuable tool for proteomics research and bioanalysis.

  17. Detecting trace components in liquid chromatography/mass spectrometry data sets with two-dimensional wavelets

    Science.gov (United States)

    Compton, Duane C.; Snapp, Robert R.

    2007-09-01

    TWiGS (two-dimensional wavelet transform with generalized cross validation and soft thresholding) is a novel algorithm for denoising liquid chromatography-mass spectrometry (LC-MS) data for use in "shot-gun" proteomics. Proteomics, the study of all proteins in an organism, is an emerging field that has already proven successful for drug and disease discovery in humans. There are a number of constraints that limit the effectiveness of liquid chromatography-mass spectrometry (LC-MS) for shot-gun proteomics, where the chemical signals are typically weak, and data sets are computationally large. Most algorithms suffer greatly from a researcher driven bias, making the results irreproducible and unusable by other laboratories. We thus introduce a new algorithm, TWiGS, that removes electrical (additive white) and chemical noise from LC-MS data sets. TWiGS is developed to be a true two-dimensional algorithm, which operates in the time-frequency domain, and minimizes the amount of researcher bias. It is based on the traditional discrete wavelet transform (DWT), which allows for fast and reproducible analysis. The separable two-dimensional DWT decomposition is paired with generalized cross validation and soft thresholding. The Haar, Coiflet-6, Daubechie-4 and the number of decomposition levels are determined based on observed experimental results. Using a synthetic LC-MS data model, TWiGS accurately retains key characteristics of the peaks in both the time and m/z domain, and can detect peaks from noise of the same intensity. TWiGS is applied to angiotensin I and II samples run on a LC-ESI-TOF-MS (liquid-chromatography-electrospray-ionization) to demonstrate its utility for the detection of low-lying peaks obscured by noise.

  18. Analysis of estrogens and androgens in postmenopausal serum and plasma by liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Wang, Qingqing; Bottalico, Lisa; Mesaros, Clementina; Blair, Ian A

    2015-07-01

    Liquid chromatography-selected reaction monitoring/mass spectrometry-based methodology has evolved to the point where accurate analyses of trace levels of estrogens and androgens in postmenopausal serum and plasma can be accomplished with high precision and accuracy. A suite of derivatization procedures has been developed, which together with modern mass spectrometry instrumentation provide investigators with robust and sensitive methodology. Pre-ionized derivatives are proving to be useful as they are not subject to suppression of the electrospray signal. Postmenopausal women with elevated plasma or serum estrogens are thought to be at increased risk for breast and endometrial cancer. Therefore, significant advances in risk assessment should be possible now that reliable methodology is available. It is also possible to conduct analyses of multiple estrogens in plasma or serum. Laboratories that are currently employing liquid chromatography/mass spectrometry methodology can now readily implement this strategy. This will help conserve important plasma and serum samples available in Biobanks, as it will be possible to conduct high sensitivity analyses using low initial sample volumes. Reported levels of both conjugated and non-conjugated estrogen metabolites are close to the limits of sensitivity of many assays to date, urging caution in the interpretation of these low values. The analysis of serum androgen precursors in postmenopausal women has not been conducted routinely in the past using liquid chromatography/mass spectrometry methodology. Integration of serum androgen levels into the panel of metabolites analyzed could provide additional information for assessing cancer risk and should be included in the future.

  19. Salting-out homogenous extraction followed by ionic liquid/ionic liquid liquid-liquid micro-extraction for determination of sulfonamides in blood by high performance liquid chromatography.

    Science.gov (United States)

    Liu, Zhongling; Yu, Wei; Zhang, Hanqi; Gu, Fanbin; Jin, Xiangqun

    2016-12-01

    Salting-out homogenous extraction followed by ionic liquid/ionic liquid dispersive liquid-liquid micro-extraction system was developed and applied to the extraction of sulfonamides in blood. High-performance liquid chromatography was applied to the determination of the analytes. The blood sample was centrifuged to obtain the serum. After the proteins in the serum were removed in the presence of acetonitrile, ionic liquid 1-butyl-3-methylimidazolium tetrafluoroborate, dipotassium hydrogen phosphate, ionic liquid 1-Hexyl-3-methylimidazolium hexafluorophosphate were added into the resulting solution. After the resulting mixture was ultrasonically shaken and centrifuged, the precipitate was separated. The acetonitrile was added in the precipitate and the analytes were extracted into the acetonitrile phase. The parameters affecting the extraction efficiency, such as volume of ionic liquid, amount of dipotassium hydrogen phosphate, volume of dispersant, extraction time and temperature were investigated. The limits of detection of sulfamethizole (STZ), sulfachlorpyridazine (SCP), sulfamethoxazole (SMX) and Sulfisoxazole (SSZ) were 4.78, 3.99, 5.21 and 3.77μgL(-1), respectively. When the present method was applied to the analysis of real blood samples, the recoveries of analytes ranged from 90.0% to 113.0% and relative standard deviations were lower than 7.2%.

  20. Combining Laser Ablation/Liquid Phase Collection Surface Sampling and High-Performance Liquid Chromatography Electrospray Ionization Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Ovchinnikova, Olga S [ORNL; Kertesz, Vilmos [ORNL; Van Berkel, Gary J [ORNL

    2011-01-01

    This paper describes the coupling of ambient pressure transmission geometry laser ablation with a liquid phase sample collection method for surface sampling and ionization with subsequent mass spectral analysis. A commercially available autosampler was adapted to produce a liquid droplet at the end of the syringe injection needle while in close proximity to the surface to collect the sample plume produced by laser ablation. The sample collection was followed by either flow injection or a high performance liquid chromatography (HPLC) separation of the extracted components and detection with electrospray ionization mass spectrometry (ESI-MS). To illustrate the analytical utility of this coupling, thin films of a commercial ink sample containing rhodamine 6G and of mixed isobaric rhodamine B and 6G dyes on glass microscope slides were analyzed. The flow injection and HPLC/ESI-MS analysis revealed successful laser ablation, capture and, with HPLC, the separation of the two compounds. The ablated circular area was about 70 m in diameter for these experiments. The spatial sampling resolution afforded by the laser ablation, as well as the ability to use sample processing methods like HPLC between the sample collection and ionization steps, makes this combined surface sampling/ionization technique a highly versatile analytical tool.

  1. Determination of tocopherols and tocotrienols in cereals by pressurized liquid extraction-liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Bustamante-Rangel, M; Delgado-Zamarreño, M M; Sánchez-Pérez, A; Carabias-Martínez, R

    2007-03-28

    A rapid analytical method including pressurized liquid extraction (PLE) and liquid chromatography-electrospray ionisation-mass spectrometry (LC-ESI-MS) has been developed for the determination of tocopherols and tocotrienols in cereals. The pressurized liquid extraction parameters were optimized in order to maximize the extraction efficiency. The use of methanol as extraction solvent at a temperature of 50 degrees C and a pressure of 110 bar, using one cycle of extraction with a static time of 5 min, provided the best results. A good LC separation was achieved using a C(18) column and a solution of 6.0 mM ammonia in methanol/water (97:3, v/v) as the mobile phase at a flow rate of 0.2 mL min(-1). MS coupling with an ESI interface in the negative ion mode was used as the detection technique. In the present work, it is shown that the addition of a base to the mobile phase is required to enhance the ionization of tocopherols and tocotrienols in negative ion mode electrospray ionization. The applicability of the method to cereal samples was confirmed. The reproducibility of the procedure was good, with relative standard deviations in the 6-10% range. The recoveries of added tocopherols from cereal samples ranged from 91 to 109%.

  2. Development of an enhanced separation of erythromycin and its related substances by liquid chromatography.

    Science.gov (United States)

    Deubel, A; Holzgrabe, U

    2007-01-17

    A new HPLC-UV method for the determination of the impurity profile of erythromycin is developed. In contrast to the liquid chromatography described in the European Pharmacopoeia the analysis could be performed at a temperature of 25 degrees C. Erythromycin samples were analysed on an endcapped RP phase with cyanopropyl groups on the surface using gradient elution with 32 mM potassium phosphate buffer pH 8.0 and acetonitrile/methanol (75:25). The aforementioned method shows clear improvements compared to the actual method of the European Pharmacopoeia, which is less selective and sensitive.

  3. On-line radiochemical assay for monoamine oxidase utilizing high-performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Nissinen, E.; Linko-Loeppoenen SMae; Maennistoe P4

    1984-12-01

    A fast and sensitive assay for the determination of monoamine oxidase activity was developed. The method is based on the separation and quantitation of /sup 14/C-labeled assay products by high-performance liquid chromatography, which is interfaced directly into a flow-through radioactivity detector. This allows on-line quantitation of the radioactive compounds with picomole sensitivity. The method makes possible the complete separation and detection of the deaminated products of monoamine oxidase A and B substrates benzylamine and 5-hydroxytryptamine, respectively. This assay has been applied to the measurement of monoamine oxidase A and B activities in rat brain.

  4. Determination of enantiomeric impurity of etomidate by high performance liquid chromatography

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    Objective To determine enantiomeric impurity of etomidate using high performance liquid chromatography. Methods (R)-etomidate and (S)-etomidate were separated on a CHIRALPAK AD-H column. The mobile phase consisted of 20∶80(v/v) isopropanol-n-hexane. The flow rate of the mobile phase was 0.5mL/min. The detected wavelength was 242nm. Results (R)-etomidate and (S)-etomidate could be separated completely under these conditions. The precision of (R)-etomidate was 1.57% (n=3). The limit of detection of (R)-etomid...

  5. Anomalous properties of flavonoids in reversed phase high performance liquid chromatography

    Science.gov (United States)

    Zenkevich, I. G.; Gushchina, S. V.

    2011-09-01

    It is shown through reversed phase high performance liquid chromatography that a characteristic feature of such abundant natural flavonoids as flavon-3-ols is an anomalously strong antibate dependence of their retention indices ( RI) on the organic solvent concentration ( C) in the eluent, dRI/ dC < 0. In order to interpret this anomaly, the specific optical rotation values [α]{D/20} of natural (+)-(2 R,3 R)-dihydroquercetin in different solvents are compared, confirming the reverse formation of hydrated flavonoids in aqueous solutions.

  6. Study of Saiga Horn Using High-Performance Liquid Chromatography with Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Kateřina Mikulíková

    2012-01-01

    Full Text Available The saiga horns have been investigated the using of modern analytic methods. High-performance liquid chromatography (HPLC with mass-spectrometric (MS and MS/MS detection and polyacrylamide gel electrophoresis (PAGE were used. It could be concluded that basic proteins of the saiga horns are keratins and collagen. The basic representation protein in all samples is keratin type I microfibrillar (from sheep, keratin type II microfibrillar (from sheep, collagen type I (α1 (from bovine and collagen type I (α2 (from bovine. Free amino acids we determined in all samples are nontreated by enzyme.

  7. Determination of cortisol and cortisone in urine using high-performance liquid chromatography with UV detection.

    Science.gov (United States)

    Jenner, D A; Richards, J

    1985-01-01

    The application of reversed-phase gradient high-performance liquid chromatography with UV detection to the determination of cortisol and cortisone in 24-h urine samples is described. The method employs Sep-pak C18 cartridges for the part-purification and concentration of the corticosteroids, with sample enrichment at the head of an HPLC pre-column and separation using water/acetonitrile gradient. The internal standard is 6alpha-methylprednisolone. Measurement of both cortisone and cortisol provides further information on adrenocortical function. 24-hour excretion rate data from normal subjects are reported.

  8. Determination of rhoifolin and daidzin in human plasma by high-performance liquid chromatography.

    Science.gov (United States)

    Ishii, K; Urano, S; Furuta, T; Kasuya, Y

    1994-05-13

    A method for determining flavonoids in human plasma is presented for application to pharmacokinetic studies of two flavonoids, rhoifolin and daidzin. Isocratic reversed-phase high-performance liquid chromatography (HPLC) was used with genistin as an internal standard and solid-phase extraction using a Sep-Pak C18 cartridge. The mobile phases were acetonitrile-0.1 M ammonium acetate solution (20:80, v/v) for rhoifolin and methanol-0.1 M ammonium acetate solution (33:67, v/v) for daidzin. The detection limits on-column were 2 ng for rhoifolin and 0.5 ng for daidzin.

  9. Tools to discover anionic and nonionic polyfluorinated alkyl surfactants by liquid chromatography electrospray ionisation mass spectrometry

    DEFF Research Database (Denmark)

    Trier, Xenia; Granby, Kit; Christensen, Jan H.

    2011-01-01

    A tiered approach is proposed for the discovery of unknown anionic and nonionic polyfluorinated alkyl surfactants (PFASs) by reversed phase ultra high performance liquid chromatography (UHPLC) – negative electrospray ionisation – quadrupole time of flight mass spectrometry (UHPLC......–ESI−–QTOF–MS). The chromatographic separation, ionisation and detection of PFASs mixtures, was achieved at high pH (pH=9.7) with NH4OH as additive. To distinguish PFASs from other chemicals we used the characteristic negative mass defects of PFASs, their specific losses of 20Da (HF) and the presence of series of chromatographic...

  10. Quantitative analysis of forskolin in Coleus forskohlii (Lamiaceae) by reversed-phase liquid chromatography.

    Science.gov (United States)

    Schaneberg, Brian T; Khan, Ikhlas A

    2003-01-01

    A rapid method was developed for the evaluation of forskolin in Coleus forskohlii Briq. (Lamiaceae). Forskolin was quantitated in the root and stem of dried C. forskohlii and in 17 market products by reversed-phase liquid chromatography (LC) with a photodiode array detector at 210 nm. The temperature was held constant at 30 degrees C, and the retention time of forskolin was approximately 6.8 min. The samples were extracted with acetonitrile by sonication. The precision of the method was confirmed by a standard deviation forskohlii plant material and in market products claiming to contain C. forskohlii.

  11. Separation analysis of some food constituents and Durification of enzyme in food by liquid chromatography

    OpenAIRE

    大槻, 耕三; 松尾, 亜希子; 尾原, 宏美; 宮田, 真理子; 村西, 映美; 佐藤, 健司; 中村, 孝志; KOZO, OHTSUKI; AKIKO, MATSUO; HIROMI, OBARA; MARIKO, MIYATA; TERUMI, MURANISHI; KENJI, SATO; YASUSHI, NAKAMURA; 京都府立大学人間環境学部食保健学科食品科学研究室

    2004-01-01

    Liquid chromatography and HPLC were successfully used for the determination of some food constituents and the purification of an enzyme in food. Free and total amino acids, water extracts and 6N-HC1 vapor hydrolysates in foods were analyzed in an ion-exchange HPLC-amino acid analyzer with lithium citrate buffers and post-column fluorimetric detection with o-phthalaldehyde - N-acetyl-L-Cysteine reagent. Tryptophan content in green tea, Mat-Cha, was also analyzed in an HPLC with fluorimetric de...

  12. Stationary phase optimized selectivity liquid chromatography: Basic possibilities of serially connected columns using the "PRISMA" principle.

    Science.gov (United States)

    Nyiredy, Sz; Szucs, Zoltán; Szepesy, L

    2007-07-20

    A new procedure (stationary phase optimized selectivity liquid chromatography: SOS-LC) is described for the optimization of the HPLC stationary phase, using serially connected columns and the principle of the "PRISMA" model. The retention factors (k) of the analytes were determined on three different stationary phases. By use of these data the k values were predicted applying theoretically combined stationary phases. These predictions resulted in numerous intermediate theoretical separations from among which only the optimal one was assembled and tested. The overall selectivity of this separation was better than that of any individual base stationary phase. SOS-LC is independent of the mechanism and the scale of separation.

  13. Impurity profiling and in-process testing of drugs for injection by fast liquid chromatography

    Institute of Scientific and Technical Information of China (English)

    Marie-Josee Rocheleau; Elaine Larouche; Cristina Salamu; Mihaela Curca

    2012-01-01

    Liquid chromatography (LC) is considered by many as a mature technique. Nonetheless, LC technology continues to evolve driven by the need for high-throughput and high-resolution analyses. Over the past several years, small particle size packing materials have been introduced by several column manufacturers to enable fast and efficient LC separations. Several examples of pharmaceutical analyses, including impurity profiling of taxanes and atracurium besylate, in-process testing of peptides in injectable dosage form, using sub-2 um column technology are presented in this paper, demonstrating some of the capabilities and limitations of the technology.

  14. Detection of cheese whey and caseinomacropeptide in fermented milk beverages using high performance liquid chromatography

    OpenAIRE

    E.H.P. Andrade; M.R. Souza; Fonseca,L.M.; C.F.A.M. Penna; M.M.O.P. Cerqueira; T. Roza; Seridan,B.; M.F.S. Resende; Pinto, F. A.; C.N.B.C. Villanoeva; Leite,M.O.

    2014-01-01

    Cheese whey level and caseinomacropeptide (CMP) index of fermented milk beverages added with four levels of cheese whey (0, 10, 20, and 40%) and stored at 8-10oC for 0, 7, 14 and 21 days were determined by high performance liquid chromatography-gel filtration (HPLC-GF). Additionally, the interference of the starter culture and the storage time on the detection of cheese whey and CMP were investigated. Refrigerated storage up to 21 days did not affect (P>0.05) cheese whey and CMP amounts in mi...

  15. Characterization of oil sands process-affected waters by liquid chromatography orbitrap mass spectrometry.

    Science.gov (United States)

    Pereira, Alberto S; Bhattacharjee, Subir; Martin, Jonathan W

    2013-05-21

    Recovery of bitumen from oil sands in northern Alberta, Canada, occurs by surface mining or in situ thermal recovery, and both methods produce toxic oil sands process-affected water (OSPW). A new characterization strategy for surface mining OSPW (sm-OSPW) and in situ OSPW (is-OSPW) was achieved by combining liquid chromatography with orbitrap mass spectrometry (MS). In electrospray positive and negative ionization modes (ESI(+)/ESI(-)), mass spectral data were acquired with high resolving power (RP > 100,000-190,000) and mass accuracy (method should be further applied to environmental forensic analysis of water in the region.

  16. Analyzing Activities of Lytic Polysaccharide Monooxygenases by Liquid Chromatography and Mass Spectrometry

    DEFF Research Database (Denmark)

    Westereng, Bjørge; Arntzen, Magnus Ø.; Wittrup Agger, Jane

    2017-01-01

    , whereas C4 oxidation leads to products that are inherently labileat high and low pH and that exist in a keto-gemdiol equilibrium that is strongly shifted toward the gemdiolin aqueous solutions. Partial degradation of C4-oxidized products leads to the formation of native products,which could explain why...... necessitate the use of sensitive product detection methods, which limits the analytical possibilities considerably. Modern liquid chromatography and mass spectrometry have become essential tools for evaluating LPMO activity, and this chapter provides an overview of available methods together with a few novel...

  17. Determination of urinary vanillylmandelic acid by liquid chromatography with electrochemical detection.

    Science.gov (United States)

    Moleman, P; Borstrok, J J

    1983-05-01

    We describe an improved method for the assay of urinary vanillylmandelic acid by "high-performance" liquid chromatography, with electrochemical detection. A 1-mL aliquot of urine is acidified and extracted with ethyl acetate, then the ethyl acetate extract is extracted with phosphate buffer, pH 8.5. An acidified aliquot of the phosphate extract is injected into a reversed-phase column and vanillylmandelic acid is detected electrochemically. The between-day CV is 5-6% for concentrations ranging from 10 to 75 mumol/L. We also discuss the critical steps for extraction and calibration.

  18. Separation of polyamines, conjugated to DNA, by reversed-phase high-performance liquid chromatography.

    Science.gov (United States)

    Mateos, J L; Reyes, A; Vicente, C; Legaz, M E

    2000-02-18

    Genomic DNA was isolated from the lichen Evernia prunastri in order to analyze by high-performance liquid chromatography the occurrence of polyamines conjugated to the macromolecule. The acid-insoluble (PH) fraction of this DNA contained mainly conjugated spermidine, although small amounts of free putrescine and spermidine were also present. The PH fraction of DNA also contained conjugated evernic acid, the main phenol produced by this lichen species. Conjugation of polyamines to calf thymus DNA was carried out under in vitro conditions. Conjugation was to spermidine and mainly to spermine and produced DNA compactation. Evernic acid enhanced the action of polyamines in order to produce DNA aggregation.

  19. Chiral separation of pharmaceutical compounds using electrochemically modulated liquid chromatography (EMLC)

    Energy Technology Data Exchange (ETDEWEB)

    Wang, S. [Iowa State Univ., Ames, IA (United States)

    1999-02-12

    This research explores the application of a new technique, termed electrochemically modulated liquid chromatography (EMLC), to the chiral separations of pharmaceutical compounds. The introduction section provides a literature review of the technique and its applications, as well as brief overview of the research described in each of the next two chapters. Chapter 2 investigates the EMLC-based enantiomeric separation of a group of chiral benzodiazepines with β-cyclodextrin as a chiral mobile phase additive. Chapter 3 demonstrates the effects of several experimental parameters on the separation efficiency of drug enantiomers. The author concludes with a general summary and possible directions for future studies. Chapters 2 and 3 are processed separately.

  20. Determination of furanochromones and pyranocoumarins in drugs and Ammi visnaga fruits by combined solid-phase extraction-high-performance liquid chromatography and thin-layer chromatography-high-performance liquid chromatography.

    Science.gov (United States)

    Zgórka, G; Dragan, T; Głowniak, K; Basiura, E

    1998-02-27

    A new, simple and rapid solid-phase extraction method for the determination of furanochromones and pyranocoumarins in Ammi visnaga L. fruits and pharmaceuticals by reversed-phase high-performance liquid chromatography (RP-HPLC) was developed. The isolation of compounds examined was carried out on octadecyl BakerBond SPE columns using various concentrations of methanol, acetonitrile and tetrahydrofuran in water. High and reproducible recoveries were obtained. To compare the results of quantitative analysis a preparative TLC procedure was also elaborated and carried out.

  1. Quantitative Analysis of Tetramethylenedisulfotetramine ("Tetramine") Spiked into Beverages by Liquid Chromatography Tandem Mass Spectrometry with Validation by Gas Chromatography Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Owens, J; Hok, S; Alcaraz, A; Koester, C

    2008-11-13

    Tetramethylenedisulfotetramine, commonly known as tetramine, is a highly neurotoxic rodenticide (human oral LD{sub 50} = 0.1 mg/kg) used in hundreds of deliberate food poisoning events in China. Here we describe a method for quantitation of tetramine spiked into beverages, including milk, juice, tea, cola, and water and cleaned up by C8 solid phase extraction and liquid-liquid extraction. Quantitation by high performance liquid chromatography tandem mass spectrometry (LC/MS/MS) was based upon fragmentation of m/z 347 to m/z 268. The method was validated by gas chromatography mass spectrometry (GC/MS) operated in SIM mode for ions m/z 212, 240, and 360. The limit of quantitation was 0.10 {micro}g/mL by LC/MS/MS versus 0.15 {micro}g/mL for GC/MS. Fortifications of the beverages at 2.5 {micro}g/mL and 0.25 {micro}g/mL were recovered ranging from 73-128% by liquid-liquid extraction for GC/MS analysis, 13-96% by SPE and 10-101% by liquid-liquid extraction for LC/MS/MS analysis.

  2. Speciation of cisplatin in environmental water samples by hydrophilic interaction liquid chromatography coupled to inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Vidmar, Janja; Martinčič, Anže; Milačič, Radmila; Ščančar, Janez

    2015-06-01

    Cisplatin is still widely used for treatment of numerous types of tumours. Different speciation methods have been applied to study behaviour of the intact drug and its individual biotransformation species in various clinical samples. These methods are mainly based on electrophoresis, size exclusion (SEC) or ion chromatography (IC) techniques coupled to inductively coupled plasma mass spectrometry (ICP-MS). Hydrophilic interaction liquid chromatography (HILIC), which is a common technique for separation of polar substances, was rarely applied for separation of cisplatin and its hydrolysed metabolites. There is also a lack of information available on the occurrence of cisplatin and its hydrolysed complexes in the environmental waters. In the present study the concentrations of Pt were determined in hospital wastewaters by ICP-MS. A procedure for separation of cisplatin and its aqueous hydrolysed complexes by the use of HILIC column was optimized. Quantification of separated Pt species was performed by isotope dilution (ID)-ICP-MS procedure. Low limits of detection (LODs) and quantification (LOQs) were obtained for cisplatin and its hydrolysed complexes ranging from 0.0273 to 0.1726 ng Pt/mL and from 0.0909 to 0.5753 ng Pt/mL, respectively. Good repeatability of the procedure with relative standard deviation (RSD) lower than ±2.3% was obtained. The column recoveries, which ranged from 95 to 101%, indicated that the procedure developed enabled quantitative speciation analysis of aqueous cisplatin complexes. The ZIC-HILIC-ID-ICP-MS procedure was successfully applied in speciation of cisplatin in spiked hospital wastewater samples.

  3. Quantitative determination of gymnodimine-A by high performance liquid chromatography in contaminated clams from Tunisia coastline.

    Science.gov (United States)

    Marrouchi, Riadh; Dziri, Faten; Belayouni, Nawel; Hamza, Asma; Benoit, Evelyne; Molgó, Jordi; Kharrat, Riadh

    2010-10-01

    Quantitative determination by high performance liquid chromatography (HPLC) was performed for gymnodimine-A (GYM-A), a phycotoxin responsible for the contamination of Tunisian clams. This study demonstrates a rapid and reproducible HPLC-ultraviolet (UV) method for extraction, detection and quantification of GYM-A in toxic clams. The extraction of GYM-A from the digestive gland of clams in acetone, subsequent clean-up with diethyl ether and extraction with dichloromethane is the more valid protocol. Chromatography analyses were performed using a gradient of acetonitrile-water (10:90 to 90:10), containing trifluoroacetic acid (0.1%) for 20 min at 1 mL/min rate with a C18 column. Recovery rates exceeded 96%, and limits of detection and quantification were 5 ng/mL and 8 ng/g digestive gland, respectively. Repeatability and reproducibility were tested for various samples containing different levels of GYM-A. A significant correlation was observed between toxicity level of samples and the determined amount of GYM-A. Also, the persistence of GYM-A in contaminated clams from Boughrara lagoon was demonstrated. The kinetics discharge study of GYM-A in controlled medium, during 1 month, showed that the process of depuration was biphasic with an exponential discharge of 75% of the total amount of sequestered GYM-A during the first 12 days followed by a slow discharge (>10%) for the subsequent days up to the seventeenth day. This is the first time that a quantitative study of GYM-A in clams from Tunisian coasts is performed through the development of a new method for detection and quantify of this phycotoxin. We found HPLC-UV a reliable and suitable alternative to the mouse bioassay.

  4. Simultaneous quantitative analysis of eight vitamin D analogues in milk using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Gomes, Fabio P; Shaw, P Nicholas; Whitfield, Karen; Hewavitharana, Amitha K

    2015-09-01

    Milk is an important source of nutrients for various risk populations, including infants. The accurate measurement of vitamin D in milk is necessary to provide adequate supplementation advice for risk groups and to monitor regulatory compliance. Currently used liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods are capable of measuring only four analogues of vitamin D in unfortified milk. We report here an accurate quantitative analytical method for eight analogues of vitamin D: Vitamin D2 and D3 (D2 and D3), 25-hydroxy D2 and D3, 24,25-dihydroxy D2 and D3, and 1,25-dihydroxyD2 and D3. In this study, we compared saponification and protein precipitation for the extraction of vitamin D from milk and found the latter to be more effective. We also optimised the pre-column derivatisation using 4-phenyl-l,2,4-triazoline-3,5-dione (PTAD), to achieve the highest sensitivity and accuracy for all major vitamin D forms in milk. Chromatography was optimised to reduce matrix effects such as ion-suppression, and the matrix effects were eliminated using co-eluting stable isotope labelled internal standards for the calibration of each analogue. The analogues, 25-hydroxyD3 (25(OH)D3) and its epimer (3-epi-25(OH)D3) were chromatographically resolved, to prevent over-estimation of 25(OH)D3. The method was validated and subsequently applied for the measurement of total vitamin D levels in human, cow, mare, goat and sheep milk samples. The detection limits, repeatability standard deviations, and recovery ranges were from 0.2 to 0.4 femtomols, 6.30-13.5%, and 88.2-105%, respectively.

  5. Determination of fenbendazole, praziquantel and pyrantel pamoate in dog plasma by high-performance liquid chromatography.

    Science.gov (United States)

    Morovján, G; Csokán, P; Makranszki, L; Abdellah-Nagy, E A; Tóth, K

    1998-02-27

    Simple and rapid high-performance liquid chromatographic methods were developed for the determination of fenbendazole, praziquantel and pyrantel pamoate in dog plasma. The combination of these drugs is the most powerful treatment against most types of worms. Blood plasma samples obtained in a pharmacokinetic trial were prepared using solid-phase extraction. Fenbendazole and praziquantel were analyzed simultaneously by reversed-phase high-performance liquid chromatography on an octadecyl-modified silica stationary phase employing acetonitrile-phosphate buffer (pH 3.0) eluent and ultraviolet detection at 220 nm. Pyrantel was analyzed separately on a base-deactivated reversed-phase column using methanol-tetrahydrofuran-ammonium acetate buffer (pH 4.6) eluent and ultraviolet detection at 317 nm. Average recoveries for fenbendazole, praziquantel and pyrantel pamoate were 76.8, 93.4 and 90.5%, respectively. Limits of quantitation were in the range of 15-25 ng/ml plasma.

  6. Saffron authentication based on liquid chromatography high resolution tandem mass spectrometry and multivariate data analysis.

    Science.gov (United States)

    Rubert, Josep; Lacina, Ondrej; Zachariasova, Milena; Hajslova, Jana

    2016-08-01

    Saffron is one of the oldest and most expensive spices, which is often target of fraudulent activities. In this research, a new strategy of saffron authentication based on metabolic fingerprinting was developed. In the first phase, a solid liquid extraction procedure was optimized, the main aim was to isolate as maximal representation of small molecules contained in saffron as possible. In the second step, a detection method based on liquid chromatography coupled with high-resolution mass spectrometry was developed. Initially, principal component analysis (PCA) revealed clear differences between saffron cultivated and packaged in Spain, protected designation of origin (PDO), and saffron packaged in Spain of unknown origin, labeled Spanish saffron. Afterwards, orthogonal partial least square discriminant analysis (OPLS-DA) was favorably used to discriminate between Spanish saffron. The tentative identification of markers showed glycerophospholipids and their oxidized lipids were significant markers according to their origin.

  7. Novel materials and methods for solid-phase extraction and liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Ambrose, Diana [Iowa State Univ., Ames, IA (United States)

    1997-06-24

    This report contains a general introduction which discusses solid-phase extraction and solid-phase micro-extraction as sample preparation techniques for high-performance liquid chromatography, which is also evaluated in the study. This report also contains the Conclusions section. Four sections have been removed and processed separately: silicalite as a sorbent for solid-phase extraction; a new, high-capacity carboxylic acid functionalized resin for solid-phase extraction; semi-micro solid-phase extraction of organic compounds from aqueous and biological samples; and the high-performance liquid chromatographic determination of drugs and metabolites in human serum and urine using direct injection and a unique molecular sieve.

  8. Novel guanidinium-based ionic liquids as stationary phases for capillary gas chromatography

    Institute of Scientific and Technical Information of China (English)

    Li Zhen Qiao; Kai Lu; Mei Ling Qi; Ruo Nong Fu

    2010-01-01

    The present study describes guanidinium-based ionic liquids(GBILs)as stationary phases for capillary gas chromatography(CGC)and to the best of our knowledge,no related reports are available up to now.In this study,a hexaalkylguanidinium ionic liquid(DOTMG-NTf2)was synthesized and coated statically onto capillary columns.Selectivity of the stationary phase was evaluated by separating Grob test mixture,test mixture,alcohols mixture,and fatty acid methyl esters mixture,and thermal stability was investigated as well.The present study demonstrates that GBILs as CGC stationary phases exhibit satisfactory selectivity and thermal stability and have a great potential as new candidates for CGC stationary phases.

  9. Profiling and quantitation of bacterial carotenoids by liquid chromatography and photodiode array detection.

    Science.gov (United States)

    Nelis, H J; De Leenheer, A P

    1989-12-01

    An analytical method for the profiling and quantitative determination of carotenoids in bacteria is described. Exhaustive extraction of the pigments from four selected bacterial strains required treatment of the cells with potassium hydroxide or liquefied phenol or both before the addition of the extracting solvent (methanol or diethyl ether). The carotenoids in the extracts were separated by nonaqueous reversed-phase liquid chromatography in conjunction with photodiode array absorption detection. The identity of a peak was considered definitive only when both its retention time and absorption spectrum, before and after chemical reactions, matched those of a reference component. In the absence of the latter, most peaks could be tentatively identified. Two examples illustrate how in the analysis of pigmented bacteria errors may result from using nonchromatographic procedures or liquid chromatographic methods lacking sufficient criteria for peak identification. Carotenoids of interest were determined quantitatively when the authentic reference substance was available or, alternatively, were determined semiquantitatively.

  10. Dispersive liquid-liquid microextraction for the determination of phenols by acetonitrile stacking coupled with sweeping-micellar electrokinetic chromatography with large-volume injection.

    Science.gov (United States)

    He, Hui; Liu, Shuhui; Meng, Zhaofu; Hu, Shibing

    2014-09-26

    The current routes to couple dispersive liquid-liquid microextraction (DLLME) with capillary electrophoresis (CE) are evaporation of water immiscible extractants and backextraction of analytes. The former is not applicable to extractants with high boiling points, the latter being effective only for acidic or basic analytes, both of which limit the further application of DLLME-CE. In this study, with 1-octanol as a model DLLME extractant and six phenols as model analytes, a novel method based on acetonitrile stacking and sweeping is proposed to accomplish large-volume injection of 1-octanol diluted with a solvent-saline mixture before micellar electrokinetic chromatography. Brij-35 and β-cyclodextrin were employed as pseudostationary phases for sweeping and also for improving the compatibility of sample zone and aqueous running buffer. A short solvent-saline plug was used to offset the adverse effect of the water immiscible extractant on focusing efficiency. The key parameters affecting separation and concentration were systematically optimized; the effect of Brij-35 and 1-octanol on focusing mechanism was discussed. Under the optimized conditions, with ∼ 30-fold concentration enrichment by DLLME, the diluted extractant (8×) was then injected into the capillary with a length of 21 cm (42% of the total length), which yielded the overall improvements in sensitivity of 170-460. Limits of detection and qualification ranged from 0.2 to 1.0 ng/mL and 1.0 to 3.4 g/mL, respectively. Acceptable repeatability lower than 3.0% for migration time and 9.0% for peak areas were obtained. The developed method was successfully applied for analysis of the phenol pollutants in real water samples.

  11. Trace-level determination of sweeteners in sewage sludge using selective pressurized liquid extraction and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Arbeláez, Paula; Borrull, Francesc; Maria Marcé, Rosa; Pocurull, Eva

    2015-08-21

    The occurrence of sweeteners in the environment has become a matter of concern due to the possibility of adverse effects on human health and wildlife species. One of the routes by which sweeteners enter the environment is through sewage sludge. Therefore, a method was developed with a selective-pressurized liquid extraction (S-PLE) followed by liquid chromatography-tandem mass spectrometry for the simultaneous determination of eight sweeteners in sewage sludge. The chromatographic separation was achieved in less than ten minutes using an amide polar-embedded reversed-phase column. Due to the high matrix effect present in the sample, an extensive study was conducted in order to overcome this issue, with C18 in-cell and solid-phase extraction (Oasis HLB) as a clean-up method. S-PLE/SPE recoveries at two levels of concentration (50μg/kg and 1000μg/kg in dry weight (d.w.), n=5) were higher than 61%. Repeatability and reproducibility at the same concentrations (%RSD, n=5) were lower than 11% and 16%, respectively. The limits of detection were 10μg/kg (d.w) for all compounds, except for cyclamate (5μg/kg (d.w.)). The method was successfully applied to sewage sludge samples from three sewage treatment plants located in Catalonia (Spain). Of the eight compounds, five were determined in all of the samples analysed, with acesulfame and saccharine being recorded at the highest concentrations of up to 481μg/kg and 591μg/kg (d.w.), respectively.

  12. Determination of geosmin and 2-methylisoborneol in water and wine samples by ultrasound-assisted dispersive liquid-liquid microextraction coupled to gas chromatography-mass spectrometry.

    Science.gov (United States)

    Cortada, Carol; Vidal, Lorena; Canals, Antonio

    2011-01-01

    A fast, simple and environmentally friendly ultrasound-assisted dispersive liquid-liquid microextraction (USADLLME) procedure has been developed to preconcentrate geosmin and 2-methylisoborneol (MIB) from water and wine samples prior to quantification by gas chromatography-mass spectrometry (GC-MS). A two-stage multivariate optimization approach was developed by means of a Plackett-Burman design for screening and selecting the significant variables involved in the USADLLME procedure, which was later optimized by means of a circumscribed central composite design. The optimum conditions were: solvent volume, 8μL; solvent type: tetrachloroethylene; sample volume, 12 mL; centrifugation speed, 2300 rpm; extraction temperature 20 °C; extraction time, 3 min; and centrifugation time, 3 min. Under the optimized experimental conditions the method gave good levels of repeatability with coefficient of variation under 11% (n=10). Limits of detection were 2 and 9 ng L⁻¹ for geosmin and MIB, respectively. Calculated calibration curves gave high levels of linearity with correlation coefficient values of 0.9988 and 0.9994 for geosmin and MIB, respectively. Finally, the proposed method was applied to the analysis of two water (reservoir and tap) samples and three wine (red, rose and white) samples. The samples were previously analyzed and confirmed free of target analytes. Recovery values ranged between 70 and 113% at two spiking levels (0.25 μg L⁻¹ and 30 ng L⁻¹) showing that the matrix had a negligible effect upon extraction. Only red wine showed a noticeable matrix effect (70-72% recovery). Similar conclusions have been obtained from an uncertainty budget evaluation study.

  13. Ultrasound-assisted dispersive liquid-liquid microextraction for the determination of synthetic musk fragrances in aqueous matrices by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Homem, Vera; Alves, Alice; Alves, Arminda; Santos, Lúcia

    2016-01-01

    A rapid and simple method for the simultaneous determination of twelve synthetic musks in water samples, using ultrasound-assisted dispersive liquid-liquid microextraction (UA-DLLME) coupled with gas chromatography-mass spectrometry (GC-MS) was successfully developed. The influence of seven factors (volume of the extraction solvent and disperser solvent, sample volume, extraction time, ionic strength, type of extraction and disperser solvent) affecting the UA-DLLME extraction efficiency was investigated using a screening design. The significant factors were selected and optimised employing a central composite design: 80 μL of chloroform, 880 μL of acetonitrile, 6 mL of sample volume, 3.5% (wt) of NaCl and 2 min of extraction time. Under the optimised conditions, this methodology was successfully validated for the analysis of 12 synthetic musk compounds in different aqueous samples (tap, sea and river water, effluent and influent wastewater). The proposed method showed enrichment factors between 101 and 115 depending on the analyte, limits of detection in the range of 0.004-54 ng L(-1) and good repeatability (most relative standard deviation values below 10%). No significant matrix effects were found, since recoveries ranged between 71% and 118%. Finally, the method was satisfactorily applied to the analysis of five different aqueous samples. Results demonstrated the existence of a larger amount of synthetic musks in wastewaters than in other water samples (average concentrations of 2800 ng L(-1) in influent and 850 ng L(-1) in effluent). Galaxolide, tonalide and exaltolide were the compounds most detected.

  14. Homogeneous liquid-liquid extraction combined with gas chromatography-electron capture detector for the determination of three pesticide residues in soils

    Energy Technology Data Exchange (ETDEWEB)

    Wang Xuedong [School of Environmental Science and Public Health, Wenzhou Medical College, Wenzhou 325035 (China)], E-mail: zjuwxd@yahoo.com.cn; Zhao Xinna; Liu Xiujuan; Li Yanyan; Fu Lingyan; Hu Jia [Key Laboratory of Pesticide and Chemical Biology of Ministry of Education, Central China Normal University, Wuhan 430079 (China); Huang Changjiang [School of Environmental Science and Public Health, Wenzhou Medical College, Wenzhou 325035 (China)

    2008-07-14

    In this study, a new method was developed for analyzing malathion, cypermethrin and lambda-cyhalothrin from soil samples by using homogeneous liquid-liquid extraction (HLLE) and gas chromatography with electron capture detector (GC-ECD). Acetone was used as extraction solvent for the extraction of target pesticides from soil samples. When the extraction process was finished, the target analytes in the extraction solvent were rapidly transferred from the acetone extract to carbon tetrachloride, using HLLE. Under the optimum conditions, linearity was obtained in the range of 0.05-40 {mu}g kg{sup -1} for malathion, 0.04-10 {mu}g kg{sup -1} for lambda-cyhalothrin and 0.05-50 {mu}g kg{sup -1} for cypermethrin, respectively. Coefficients of correlation (r{sup 2}) ranged from 0.9993 to 0.9998. The repeatability was carried out by spiking soil samples at concentration levels of 2.5 {mu}g kg{sup -1} for lambda-cyhalothrin, and 10 {mu}g kg{sup -1} for malathion and cypermethrin, respectively. The relative standard deviations (RSDs) varied between 2.3 and 9.6% (n = 3). The limits of detection (LODs), based on signal-to-noise ratio (S/N) of 3, varied between 0.01 and 0.04 {mu}g kg{sup -1}. The relative recoveries of three pesticides from soil A1, A2 and A3 at spiking levels of 2.5, 5 and 10 {mu}g kg{sup -1} were in the range of 82.20-91.60%, 88.90-110.5% and 77.10-98.50%, respectively. In conclusion, the proposed method can be successfully applied for the determination of target pesticide residues in real soil samples.

  15. Hydrophilic interaction chromatography versus reversed phase liquid chromatography coupled to mass spectrometry: effect of electrospray ionization source geometry on sensitivity.

    Science.gov (United States)

    Periat, Aurélie; Kohler, Isabelle; Bugey, Aurélie; Bieri, Stefan; Versace, François; Staub, Christian; Guillarme, Davy

    2014-08-22

    In this study, the influence of electrospray ionization (ESI) source design on the overall sensitivity achieved in hydrophilic interaction chromatography (HILIC) and reversed phase liquid chromatography (RPLC), was investigated. State-of-the-art triple quadrupole mass analyzers from AB Sciex, Agilent Technologies and Waters equipped with brand specific source geometries were tested with various mobile phase pH on 53 pharmaceutical compounds. The design of the ESI source showed to strongly influence the gain in sensitivity that can be achieved in HILIC compared to RPLC mode. The 6460 Triple Quadrupole LC/MS system from Agilent Technologies was particularly affected by mobile phase settings. Indeed, compared to RPLC conditions, 92% of the compounds had an increased signal-to-noise ratio at a flow rate of 300 μL/min in HILIC mode at pH 6, while this percentage dropped to only 7% at 1000 μL/min and pH 3. In contrast, the influence of flow rate and mobile phase pH on the gain in sensitivity between RPLC and HILIC was found very limited with the API 5000 LC/MS/MS system from AB Sciex, as only 15 to 36% of the tested compounds showed an enhanced sensitivity in HILIC mode. With the Xevo TQ-S instrument from Waters, superior sensitivity in HILIC was noticed for 85% of the compounds with optimal conditions (i.e., pH 3 and 1000 μL/min), whereas at sub-optimal conditions (i.e. pH 6 and 300 μL/min), it represented less than 50%. The gain in sensitivity observed in HILIC was found less significant with the recent LC-MS platforms used in this study than for old-generation instruments. Indeed, the improved ESI sources equipping the recent mass analyzers allow for enhanced evaporation efficiency, mainly for RPLC mobile phases containing high proportion of water and this even at high flow rates. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Comparison of microemulsion electrokinetic chromatography with high-performance liquid chromatography for fingerprint analysis of resina draconis.

    Science.gov (United States)

    Cao, Yuhua; Gong, Wenjun; Li, Nan; Yin, Changna; Wang, Yun

    2008-11-01

    Microemulsion electrokinetic chromatography (MEEKC) has been developed for fingerprint analysis of resina draconis, a substitute for sanguis draconis in the Chinese market. The microemulsion as the running buffer was made up of 3.3% (w/v) sodium dodecyl sulfate (SDS), 6.6% (w/v) n-butanol, 0.8% (w/v) n-octane, and 10 mmol/L sodium tetraborate buffer (pH 9.2), which was also used as the solvent for ultrasonic extraction of both water- and fat-soluble compounds in the traditional Chinese medicine samples. Four batches of resina draconis obtained from different pharmaceutical factories located in different geographic regions were used to establish the electrophoretic fingerprint. MEEKC was performed using a Beckman PACE/MDQ system equipped with a diode-array detector and with monitoring at 280 nm. The fingerprint of resina draconis comprised 27 common peaks within 100 min. The relative standard deviations of the relative migration time of these common peaks were less than 2.1%. Through repetitive injection of the sample solution six times in 24 h, all relative standard deviations of the migration time and peak area of loureirin A and loureirin B were less than 2.5 and 3.8%, which demonstrated that the method had good stability and reproducibility. The relative peak areas of these common peaks in the electropherograms of four batches of resina draconis were processed with two mathematical methods, the correlation coefficient and the interangle cosine, to valuate the similarity. The values of the similarity degree of all samples were more than 0.91, which showed resina draconis samples from different origins were consistent. On the other hand, high-performance liquid chromatography (HPLC) coupled with photodiode-array detection was also applied to establish the fingerprint of resina draconis. The samples were separated with a LiChrospher C(18) column using acetonitrile (solvent A) and water containing 0.1% H(3)PO(4) (solvent B) as the mobile phase in linear gradient

  17. Analysis of magnesium from magnesium stearate in pharmaceutical tablet formulations using hydrophilic interaction liquid chromatography with nano quantity analyte detection.

    Science.gov (United States)

    Risley, Donald S; Magnusson, Lars-Erik; Morow, Paul R; Aburub, Aktham

    2013-05-05

    This study demonstrates the use of hydrophilic interaction liquid chromatography with a nano quantity analyte detector for the retention, separation and detection of magnesium from magnesium stearate in tablet formulations for a drug product formulation blend containing a hydrochloride salt of a weakly basic compound as the active ingredient. The nano quantity analyte detector can provide direct detection of inactive excipients and inorganic salts lacking ultraviolet chromophores, as well as, all non-volatile compounds. The separation was accomplished using a SeQuant ZIC-HILIC column and mobile phase consisting of 32.5:32.5:35 of acetone/methanol/ammonium formate buffer (150 mM, pH 4.5). Common validation parameters were evaluated to assess the method's quantitative potential for magnesium (from magnesium stearate) including: linearity, accuracy, specificity, solution stability, repeatability, and intermediate precision. Overall, the method described in this report proved to be very robust and represents a novel technique to conveniently separate and detect magnesium from magnesium stearate in pharmaceutical preparations both quickly and accurately.

  18. Estimation of whey protein in casein coprecipitate and milk powder by high-performance liquid chromatography quantification of cysteine.

    Science.gov (United States)

    Ballin, Nicolai Z

    2006-06-14

    An analytical high-performance liquid chromatography (HPLC)-fluorescence method for indirect measuring of whey protein in casein coprecipitate and milk powder was developed. Samples were hydrolyzed with HCl, and cysteyl residues were derivatized with 3,3'-dithiodipropionic acid and 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate. The cysteine content was used to calculate the percentage of whey protein in commercial samples with use of European Union Regulation cysteine reference values in both casein and whey protein. Method validation studies were performed for caseinates and milk powder, and results indicate that the present HPLC approach can be applied as a fast method with a standard deviation of repeatability between 3.3 and 9.5%. Applicability was studied by analysis of 40 commercial caseinate samples, and all complied to European legislation with a content of whey protein not exceeding 5%. Finally, an approach used to estimate the cysteine amount in pure casein by comparison of calculated and experimental values questions the generally accepted cysteine reference value in casein, which is most likely an overestimation.

  19. Oligosaccharide substrate preferences of human extracellular sulfatase Sulf2 using liquid chromatography-mass spectrometry based glycomics approaches.

    Directory of Open Access Journals (Sweden)

    Yu Huang

    Full Text Available Sulfs are extracellular endosulfatases that selectively remove the 6-O-sulfate groups from cell surface heparan sulfate (HS chain. By altering the sulfation at these particular sites, Sulfs function to remodel HS chains. As a result of the remodeling activity, HSulf2 regulates a multitude of cell-signaling events that depend on interactions between proteins and HS. Previous efforts to characterize the substrate specificity of human Sulfs (HSulfs focused on the analysis of HS disaccharides and synthetic repeating units. In this study, we characterized the substrate preferences of human HSulf2 using HS oligosaccharides with various lengths and sulfation degrees from several naturally occurring HS sources by applying liquid chromatography mass spectrometry based glycomics methods. The results showed that HSulf2 preferentially digests highly sulfated HS oligosaccharides with zero acetyl groups and this preference is length dependent. In terms of length of oligosaccharides, HSulf2 digestion induced more sulfation decrease on DP6 (DP: degree of polymerization compared to DP2, DP4 and DP8. In addition, the HSulf2 preferentially digests the oligosaccharide domain located at the non-reducing end (NRE of the HS and heparin chain. In addition, the HSulf2 digestion products were altered only for specific isomers. HSulf2 treated NRE oligosaccharides also showed greater decrease in cell proliferation than those from internal domains of the HS chain. After further chromatographic separation, we identified the three most preferred unsaturated hexasaccharide for HSulf2.

  20. Determination of neonicotinoid insecticides and their metabolites in honey bee and honey by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Gbylik-Sikorska, Malgorzata; Sniegocki, Tomasz; Posyniak, Andrzej

    2015-05-15

    The original analytical method for the simultaneous determination and confirmation of neonicotinoids insecticides (imidacloprid, clothianidin, acetamiprid, thiametoxam, thiacloprid, nitenpyram, dinotefuran) and some of their metabolites (imidacloprid guanidine, imidacloprid olefin, imidacloprid urea, desnitro-imidacloprid hydrochloride, thiacloprid-amid and acetamiprid-N-desmethyl) in honey bee and honey was developed. Preparation of honey bee samples involves the extraction with mixture of acetonitrile and ethyl acetate followed by cleaned up using the Sep-Pak Alumina N Plus Long cartridges. Honey samples were dissolved in 1% mixture of acetonitrile and ethyl acetate with addition of TEA, then extracts were cleaned up with Strata X-CW cartridges. The identity of analytes was confirmed using liquid chromatography tandem mass spectrometry. All compounds were separated on a Luna C18 column with gradient elution. The whole procedure was validated according to the requirements of SANCO 12571/2013. The average recoveries of the analytes ranged from 85.3% to 112.0%, repeatabilities were in the range of 2.8-11.2%, within-laboratory reproducibility was in the range of 3.3-14.6%, the limits of quantitation were in the range of 0.1-0.5μgkg(-1), depending of analyte and matrices. The validated method was successfully applied for the determination of clothianidin, imidacloprid and imidacloprid urea in real incurred honey bee samples and clothianidin in honey. Copyright © 2015 Elsevier B.V. All rights reserved.