WorldWideScience

Sample records for repeat biopsy session

  1. Prostate atypia: does repeat biopsy detect clinically significant prostate cancer?

    Science.gov (United States)

    Dorin, Ryan P; Wiener, Scott; Harris, Cory D; Wagner, Joseph R

    2015-05-01

    While the treatment pathway in response to benign or malignant prostate biopsies is well established, there is uncertainty regarding the risk of subsequently diagnosing prostate cancer when an initial diagnosis of prostate atypia is made. As such, we investigated the likelihood of a repeat biopsy diagnosing prostate cancer (PCa) in patients in which an initial biopsy diagnosed prostate atypia. We reviewed our prospectively maintained prostate biopsy database to identify patients who underwent a repeat prostate biopsy within one year of atypia (atypical small acinar proliferation; ASAP) diagnosis between November 1987 and March 2011. Patients with a history of PCa were excluded. Chart review identified patients who underwent radical prostatectomy (RP), radiotherapy (RT), or active surveillance (AS). For some analyses, patients were divided into two subgroups based on their date of service. Ten thousand seven hundred and twenty patients underwent 13,595 biopsies during November 1987-March 2011. Five hundred and sixty seven patients (5.3%) had ASAP on initial biopsy, and 287 (50.1%) of these patients underwent a repeat biopsy within one year. Of these, 122 (42.5%) were negative, 44 (15.3%) had atypia, 19 (6.6%) had prostatic intraepithelial neoplasia, and 102 (35.6%) contained PCa. Using modified Epstein's criteria, 27/53 (51%) patients with PCa on repeat biopsy were determined to have clinically significant tumors. 37 (36.3%) proceeded to RP, 25 (24.5%) underwent RT, and 40 (39.2%) received no immediate treatment. In patients who underwent surgery, Gleason grade on final pathology was upgraded in 11 (35.5%), and downgraded 1 (3.2%) patient. ASAP on initial biopsy was associated with a significant risk of PCa on repeat biopsy in patients who subsequently underwent definitive local therapy. Patients with ASAP should be counseled on the probability of harboring both clinically significant and insignificant prostate cancer. © 2015 Wiley Periodicals, Inc.

  2. A review of repeat prostate biopsies and the influence of technique on cancer detection: our experience.

    LENUS (Irish Health Repository)

    Quinlan, M R

    2012-02-01

    BACKGROUND: Follow-up of patients with an initial negative prostate biopsy, but surrounding whom a suspicion of prostate cancer persists, is difficult. In addition, debate exists as to the optimal technique for repeat prostate biopsy. AIMS: To assess the cancer detection rate on repeat prostate biopsy. METHODS: We reviewed patients who underwent prostate biopsy in our department in 2005 who had >or=1 previous biopsy within the preceding 5 years. Cancer detection rate on repeat biopsy and the influence of the number of biopsy cores were recorded. RESULTS: Cancer detection rate on repeat biopsy was 15.4%, with approximately 60% detected on the first repeat biopsy, but approximately 10% not confirmed until the fourth repeat biopsy. Gleason score was similar regardless of the time of diagnosis (6.1-6.5). Mean interval between first biopsy and cancer diagnosis (range 18-55 months) depended on the number of repeat procedures. There was an association between the number of biopsy cores and cancer detection. CONCLUSIONS: This study supports the practice of increasing the number of cores taken on initial and first repeat biopsy to maximise prostate cancer detection and reduce the overall number of biopsies needed.

  3. The diagnosis of cancer in thyroid fine needle aspiration biopsy. Surgery, repeat biopsy or specimen consultation?

    Directory of Open Access Journals (Sweden)

    Agata Stanek-Widera

    2016-05-01

    Full Text Available Fine needle aspiration biopsy (FNA is the only diagnostic method that allows a preoperative diagnosis of thyroid carcinoma. An unequivocal diagnosis of a malignant change is achievable only in cases in which all cytological criteria of carcinoma are met. The aim of the study was to evaluate the necessity of repeat thyroid FNA in patients with papillary thyroid carcinoma verified on consultative examination (CE. We analyzed cytology reports of thyroid FNA and CE that resulted in the diagnosis of papillary carcinoma. Evaluation of the correlation of the cytological diagnosis with the histopathology report was based on data obtained after the surgery. Between 2010 and 2015 in the Institute of Oncology (IO there were 184 cancers diagnosed on CE or in thyroid FNA performed primarily in IO. Additionally, 74 patients were subjected to repeat biopsy after confirmation of cancer in CE. Histopathological diagnosis of cancer was obtained in 62 (100% cases that were doubly confirmed with cytological examination. The remaining 12 patients were operated on outside the institute. From 110 FNA primarily performed in the IO, histopathological verification was achievable in 92 cases, from which 92 (100% provided a confirmation of cancer, and the remaining 18 patients were operated on outside the institute. High (100% specificity of cancer diagnosis in FNA established primarily and verified on CE (second independent assessment indicates that repeat FNA in order to confirm the diagnosis is unnecessary.

  4. Early experience with multiparametric magnetic resonance imaging-targeted biopsies under visual transrectal ultrasound guidance in patients suspicious for prostate cancer undergoing repeated biopsy

    DEFF Research Database (Denmark)

    Boesen, Lars; Noergaard, Nis; Chabanova, Elizaveta

    2015-01-01

    OBJECTIVES: The purpose of this study was to investigate the detection rate of prostate cancer (PCa) by multiparametric magnetic resonance imaging-targeted biopsies (mp-MRI-bx) in patients with prior negative transrectal ultrasound biopsy (TRUS-bx) sessions without previous experience of this......-RADS) and Likert classification. All underwent repeated TRUS-bx (10 cores) and mp-MRI-bx under visual TRUS guidance of any mp-MRI-suspicious lesion not targeted by systematic TRUS-bx. RESULTS: PCa was found in 39 out of 83 patients (47%) and mp-MRI identified at least one lesion with some degree of suspicion...

  5. Is MR imaging useful for detecting prostate cancer in cases requiring repeat biopsy?. Presidential award proceedings

    International Nuclear Information System (INIS)

    Ito, Hirotoshi; Takahata, Akiko; Goto, Mariko; Masunami, Terutoshi; Yuen, Sachiko; Yamada, Kei; Nishimura, Tsunehiko

    2007-01-01

    The purpose of this study was to evaluate the usefulness of magnetic resonance (MR) imaging in detecting prostate cancer in cases requiring repeat biopsy. Twenty patients with negative first prostate biopsy were evaluated by T2-weighted images (T 2 W), diffusion weighted image (DWI), and contrast-enhanced dynamic MRI at 1.5T prior to repeat biopsy. Eleven of the 20 also underwent MR imaging before initial biopsy. Cancer criteria were defined as an area of low signal intensity on T 2 W, high signal intensity on DWI, and early enhancement on dynamic MR imaging. We compared MR imaging findings with biopsy results. Prostate cancer was detected by repeat biopsy in nine of 20 patients. MR imaging demonstrated the cancer lesion in seven of the 9 patients whose biopsies were positive for cancer. MR imaging of 5 patients whose biopsies showed cancer also demonstrated cancer lesion previous to initial biopsy. Most cancers were detected in the anterior, apex, and far lateral areas. False-negative cases were low-grade cancers and had a few positive biopsy cores. In patients with repeat prostate biopsy, prior MR imaging may be valuable for detecting and localizing prostate cancer. (author)

  6. Repeated biopsies in prostate cancer patients on active surveillance

    DEFF Research Database (Denmark)

    Thomsen, Frederik Birkebaek; Marcussen, Niels; Berg, Kasper Drimer

    2015-01-01

    OBJECTIVE: To investigate the clinical implications of interobserver variation in the assessment of re-biopsies obtained during active surveillance (AS). MATERIAL AND METHODS: A total of 107 low-risk prostate cancer patients with a total of 93 diagnostic biopsy sets and 109 re-biopsy sets were...... included. The ISUP 2005 Gleason scoring system was applied for the histopathological assessment of all biopsies. Three different definitions of histopathological progression were applied. Unweighted and linear weighted Kappa statistics were used to compare the interobserver agreement. RESULTS: The overall...... recommendations would have changed in up to 10.1% (95% CI: 5.4%-17.7%) of the 109 re-biopsy sets. CONCLUSION: Kappa statistics demonstrated a strong agreement between the histological evaluations. Still, up to 10% of AS patients would receive different treatment recommendation depending upon which...

  7. Anterior prostate biopsy at initial and repeat evaluation: is it useful to detect significant prostate cancer?

    Directory of Open Access Journals (Sweden)

    Pietro Pepe

    2015-10-01

    Full Text Available ABSTRACT Purpose: Detection rate for anterior prostate cancer (PCa in men who underwent initial and repeat biopsy has been prospectively evaluated. Materials and Methods: From January 2013 to March 2014, 400 patients all of Caucasian origin (median age 63.5 years underwent initial (285 cases and repeat (115 cases prostate biopsy; all the men had negative digital rectal examination and the indications to biopsy were: PSA values > 10 ng/mL, PSA between 4.1-10 or 2.6-4 ng/mL with free/total PSA≤25% and ≤20%, respectively. A median of 22 (initial biopsy and 31 cores (repeat biopsy were transperineally performed including 4 cores of the anterior zone (AZ and 4 cores of the AZ plus 2 cores of the transition zone (TZ, respectively. Results: Median PSA was 7.9 ng/mL; overall, a PCa was found in 180 (45% patients: in 135 (47.4% and 45 (36% of the men who underwent initial and repeat biopsy, respectively. An exclusive PCa of the anterior zone was found in the 8.9 (initial biopsy vs 13.3% (repeat biopsy of the men: a single microfocus of cancer was found in the 61.2% of the cases; moreover, in 7 out 18 AZ PCa the biopsy histology was predictive of significant cancer in 2 (28.5% and 5 (71.5% men who underwent initial and repeat biopsy, respectively. Conclusions: However AZ biopsies increased detection rate for PCa (10% of the cases, the majority of AZ PCa with histological findings predictive of clinically significant cancer were found at repeat biopsy (about 70% of the cases.

  8. Biopsy

    Science.gov (United States)

    ... Oropharynx lesion biopsy Pleural needle biopsy Polyp biopsy Rectal biopsy Renal biopsy Salivary gland biopsy Skin lesion ... Copyright 1997-2018, A.D.A.M., Inc. Duplication for commercial use must be authorized in writing ...

  9. Clinical validation of an epigenetic assay to predict negative histopathological results in repeat prostate biopsies.

    Science.gov (United States)

    Partin, Alan W; Van Neste, Leander; Klein, Eric A; Marks, Leonard S; Gee, Jason R; Troyer, Dean A; Rieger-Christ, Kimberly; Jones, J Stephen; Magi-Galluzzi, Cristina; Mangold, Leslie A; Trock, Bruce J; Lance, Raymond S; Bigley, Joseph W; Van Criekinge, Wim; Epstein, Jonathan I

    2014-10-01

    The DOCUMENT multicenter trial in the United States validated the performance of an epigenetic test as an independent predictor of prostate cancer risk to guide decision making for repeat biopsy. Confirming an increased negative predictive value could help avoid unnecessary repeat biopsies. We evaluated the archived, cancer negative prostate biopsy core tissue samples of 350 subjects from a total of 5 urological centers in the United States. All subjects underwent repeat biopsy within 24 months with a negative (controls) or positive (cases) histopathological result. Centralized blinded pathology evaluation of the 2 biopsy series was performed in all available subjects from each site. Biopsies were epigenetically profiled for GSTP1, APC and RASSF1 relative to the ACTB reference gene using quantitative methylation specific polymerase chain reaction. Predetermined analytical marker cutoffs were used to determine assay performance. Multivariate logistic regression was used to evaluate all risk factors. The epigenetic assay resulted in a negative predictive value of 88% (95% CI 85-91). In multivariate models correcting for age, prostate specific antigen, digital rectal examination, first biopsy histopathological characteristics and race the test proved to be the most significant independent predictor of patient outcome (OR 2.69, 95% CI 1.60-4.51). The DOCUMENT study validated that the epigenetic assay was a significant, independent predictor of prostate cancer detection in a repeat biopsy collected an average of 13 months after an initial negative result. Due to its 88% negative predictive value adding this epigenetic assay to other known risk factors may help decrease unnecessary repeat prostate biopsies. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  10. Prostate Cancer Diagnosed After Repeat Biopsies Have a Favorable Pathological Outcome but Similar Recurrence Rate

    Science.gov (United States)

    Lopez-Corona, Ernesto; Ohori, Makoto; Wheeler, Thomas M.; Reuter, Victor E.; Scardino, Peter T.; Kattan, Michael W.; Eastham, James A.

    2007-01-01

    Purpose We investigated whether repeat prostate biopsies are associated with more favorable prognoses, less extensive disease or higher rates of IC in patients who are ultimately diagnosed with prostate cancer and treated with RRP. Materials and Methods We examined standard clinical and pathological data on 1,357 patients treated with RRP from 1983 to 2001. In addition, we noted the rate of IC in a subgroup of 847 patients in whom tumor volume was measured. Results Cancer was found in 1,042 patients (77%) at the first biopsy, in 227 (17%) at the second biopsy, in 59 (4%) at the third biopsy and in 29 (2%) at the fourth or later biopsy. Patients with 2 or greater biopsies had a higher rate of clinical T1c stage cancer and larger prostates than patients with only 1 biopsy (each p <0.0001). After RRP patients with 1 biopsy had a lower rate of organ confined tumors (61% vs 75%, p <0.0001), and a higher rate of extracapsular extension, seminal vesicle invasion, lymph node metastases and Gleason sum 7 or greater than other patients. IC was found in 10% of patients with 1 biopsy and 18% of those with 2 or greater biopsies (p = 0.018). Despite these more favorable pathological outcomes there was no difference in biochemical recurrence rate. Conclusions Although we found that a greater number of biopsies was related to a better pathological outcome after RRP, the number of biopsies did not predict disease recurrence. The increasing number of biopsies currently being performed, especially in patients with larger prostates, likely results in higher rates of IC. PMID:16469581

  11. THE PROGNOSTIC AND DIAGNOSTIC VALUE OF REPEATED TRANSRECTAL PROSTATE SATURATION BIOPSY

    Directory of Open Access Journals (Sweden)

    M. A. Kurdzhiev

    2014-08-01

    Full Text Available Objective: to determine the rate of prostate cancer (PC development after repeated transrectal saturation prostate biopsy (RTRSPB, to study the characteristics of diagnosed tumors, and to estimate their clinical significance from the data of radical retropubic prostatectomy (RRP.Materials and methods. The results of RTRSPB were analyzed in 226 patients with a later evaluation of a tumor from the results of RRP. All the patients underwent at least 2 prostate biopsies (mean 2.4. The average number of biopsy cores was 26.7 (range 24—30. The average value of total prostate-specific antigen before saturation biopsy was 7.5 (range 7.5 to 28.6 ng/ml. The mean age of patients was 62 years (range 53 to 70.  Results. PC was diagnosed in 14.6% of cases (33/226. An isolated lesion of the prostatic transition zone was in 12.1% of cases. If this zone had been excluded from the biopsy scheme, the detection rate of PC during saturation biopsy should be reduced by 13.8%. Better PC detectability during repeated saturation biopsy generally occurred due to the localized forms of the disease (93.3%. The agreement of Gleason tumor grading in the biopsy and prostatectomy specimens was noted in 66.7% of cases.Conclusion. Saturation biopsy allows prediction of a pathological stage of PC, Gleason grade of a tumor and its site localization with a greater probability. Most tumors detectable by saturation biopsy were clinically significant, which makes it possible to recommend RTRSPB to some cohort of high PC-risk patients 

  12. Thyroid nodules with nondiagnostic results on repeat fine-needle aspiration biopsy: which nodules should be considered for repeat biopsy or surgery rather than follow-up?

    Energy Technology Data Exchange (ETDEWEB)

    Eun, Na Lae; Chang, Hang Seok; Gweon, Hye Mi; Kim, Jeong Ah; Youk, Ji Hyun; Son, Eun Jun [Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Yoo, Mi Ri [Dept. of Radiology, Dongjak Kyunghee Hospital, Seoul (Korea, Republic of); Park, Ah Young [Dept. of Radiology, Korea University Ansan Hospital, Korea University College of Medicine, Ansan (Korea, Republic of); Moon, Hee Jung [Dept. of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2016-07-15

    The goal of this study was to assess the clinicopathologic and ultrasonographic features of thyroid nodules with nondiagnostic results on repeat ultrasonography (US)-guided fineneedle aspiration biopsy (FNAB) according to size and the number of suspicious findings and to determine the proper management of nodules with consecutive nondiagnostic results. This retrospective study included 297 nodules with nondiagnostic results on repeat FNAB that were evaluated by US over the course of at least 12 months of follow-up, a follow-up biopsy, or an operation. We compared clinical and US variables between benign and malignant nodules in thyroid nodules with repeat nondiagnostic results. The comparison of benign and malignant nodules with repeat nondiagnostic results revealed that age, marked hypoechogenicity, irregular or microlobulated margins, microcalcifications, and nonparallel shape were significantly associated with malignancy. Multivariate logistic regression analysis in malignant nodules revealed that microcalcifications and irregular or microlobulated margins were independently associated with malignancy. Among them, only irregular or microlobulated margins were independently significant as a predictor of malignancy in repeatedly nondiagnostic nodules measuring >10 mm. Using receiver operating characteristic analysis, the best cutoff value for the “number of suspicious findings” between benign and malignant nodules was three in nodules of all sizes, three in nodules measuring ≤10 mm, and two in nodules measuring >10 mm. Irregular or microlobulated margins may be the most frequent US features in repeatedly nondiagnostic nodules >10 mm. The presence of “two or more suspicious findings” can be used as the cutoff for distinguishing benign and malignant nodules.

  13. Clinical utility of the PCA3 urine assay in European men scheduled for repeat biopsy.

    NARCIS (Netherlands)

    Haese, A.; Taille, A. De La; Poppel, H. van; Marberger, M.; Stenzl, A.; Mulders, P.F.A.; Huland, H.; Abbou, C.C.; Remzi, M.; Tinzl, M.; Feyerabend, S.; Stillebroer, A.B.; Gils, M.P.M.Q.; Schalken, J.A.

    2008-01-01

    BACKGROUND: The Prostate CAncer gene 3 (PCA3) assay has shown promise as an aid in prostate cancer (pCA) diagnosis in identifying men with a high probability of a positive (repeat) biopsy. OBJECTIVE: This study evaluated the clinical utility of the PROGENSA PCA3 assay. DESIGN, SETTING, AND

  14. Repeatability of measures of inflammatory cell number in bronchial biopsies in atopic asthma

    NARCIS (Netherlands)

    Sont, J. K.; Willems, L. N.; Evertse, C. E.; Hooijer, R.; Sterk, P. J.; van Krieken, J. H.

    1997-01-01

    Airway pathology is increasingly considered to be a major outcome in asthma research. The aim of this study was to examine the intra-observer, within-section and between-biopsy repeatability, together with the implications for statistical power of a computerized quantitative analysis of inflammatory

  15. Targeted histology sampling from atypical small acinar proliferation area detected by repeat transrectal prostate biopsy

    Directory of Open Access Journals (Sweden)

    A. V. Karman

    2017-01-01

    Full Text Available Оbjective: to define the approach to the management of patients with the detected ASAP area.Materials and methods. In the time period from 2012 through 2015, 494 patients with previously negative biopsy and remaining suspicion of prostate cancer (PCa were examined. The patients underwent repeat 24-core multifocal prostate biopsy with taking additional tissue samples from suspicious areas detected by multiparametric magnetic resonance imaging and transrectal ultrasound. An isolated ASAP area was found in 127 (25. 7 % of the 494 examined men. All of them were offered to perform repeat target transrectal biopsy of this area. Targeted transrectal ultrasound guided biopsy of the ASAP area was performed in 56 (44.1 % of the 127 patients, 53 of them being included in the final analysis.Results. PCa was diagnosed in 14 (26.4 % of the 53 patients, their mean age being 64.4 ± 6.9 years. The average level of prostate-specific antigen (PSA in PCa patients was 6.8 ± 3.0 ng/ml, in those with benign lesions – 9.3 ± 6.5 ng/ml; the percentage ratio of free/total PSA with PCa was 16.2 ± 7,8 %, with benign lesions – 23.3 ± 7.7 %; PSA density in PCa patients was 0.14 ± 0.07 ng/ml/cm3, in those with benign lesions – 0.15 ± 0.12 ng/ml/cm3. Therefore, with ASAP area being detected in repeat prostate biopsy samples, it is advisable that targeted extended biopsy of this area be performed. 

  16. Reproducibility of skeletal muscle vasodilatation responses to Stroop mental challenge over repeated sessions.

    Science.gov (United States)

    Hamer, Mark; Boutcher, Yati N; Park, Young; Boutcher, Stephen H

    2006-08-01

    Skeletal muscle blood flow responses to stress have implications for psychobiological disease pathways. An important assumption underlying psychophysiological studies relating stress reactivity with disease risk is that individuals are characterized by stable response profiles that can be reliably assessed using acute psychophysiological stress testing. We examined the reproducibility of forearm vasodilatation, blood pressure, and cardiac responses to a 2 min Stroop mental challenge over two repeated stress sessions that were on average 3.6 months apart. Participants were 21 healthy men and women (aged 21.8+/-3.7 years). Vasodilatation, blood pressure and heart rate responses displayed no habituation between sessions, although there was significantly greater cardiac parasympathetic involvement during the second testing session. Significant test-retest correlations between the sessions were observed for both forearm blood flow and heart rate reactivity. These findings demonstrate skeletal muscle vasodilatation responses to repeated stress are robust, so may be a useful psychophysiological indicator in studies of stress reactivity and disease risk.

  17. Esophageal squamous cell carcinoma presenting as submucosal lesion with repeatedly negative endoscopic biopsies

    Directory of Open Access Journals (Sweden)

    Narendra S Choudhary

    2016-01-01

    Full Text Available A 74-year-old male presented with dysphagia for 2 months. Computed tomography revealed irregular wall thickening of the esophagus at T3 to T5 level. He underwent gastroscopy which revealed a submucosal bulge with normal mucosa at 25 cm from incisors. Repeated biopsies were taken, all were negative for malignancy. The patient underwent endoscopic ultrasound, and fine-needle aspiration was taken which was suggestive for squamous cell carcinoma.

  18. Diagnosis of Hepatocellular Carcinoma Complicating Liver Cirrhosis: Utility of Repeat Ultrasound-Guided Biopsy after Unsuccessful First Sampling

    International Nuclear Information System (INIS)

    Caturelli, Eugenio; Biasini, Elisabetta; Bartolucci, Francesca; Facciorusso, Domenico; Decembrino, Francesco; Attino, Vito; Bisceglia, Michele

    2002-01-01

    Purpose: To evaluate the utility of a second ultrasound-guided fine-needle biopsy of liver nodules thought to be hepatocellular carcinoma when the original biopsy has failed to provide a reliable diagnosis. Methods: Thirty-seven cirrhotic patients underwent ultrasound-guided fine-needle biopsy of liver nodules that were subsequently diagnosed as hepatocellular carcinoma. Each biopsy involved a single puncture with a 20 G cutting needle, which yielded pathologic material used both for cytologic and histologic studies. In 23 cases (mean diameter of nodules 48 mm) the biopsy furnished exclusively necrotic material (non-diagnostic subgroup); in the other 14 cases (mean diameter 26 mm) the biopsy yielded no neoplastic elements (false-negative subgroup). All 37 nodules were subjected to repeat biopsies performed in the same manner. Results: The repeat biopsies provided a diagnosis of hepatocellular carcinoma in six of the 23 patients from the non-diagnostic subgroup and in seven of the 14 in the false-negative subgroup. Overall, repeat biopsy produced a diagnostic gain of 35.1%. Conclusion: The chance of success with repeat biopsy of hepatocellular carcinoma is limited and may depend to some extent on the characteristics of the lesions (i.e., areas of necrosis in large nodules, well-differentiated cellular populations in small ones)

  19. How repeated 15-minute assertiveness training sessions reduce wrist cutting in patients with borderline personality disorder.

    Science.gov (United States)

    Hayakawa, Masaya

    2009-01-01

    The aim of this work was to examine a possible treatment for patients with borderline personality disorder who have wrist-cutting syndrome, a condition characterized by repeated, superficial wrist cutting in a non-suicidal fashion. Within the current healthcare system in Japan, the average amount of time a doctor can spend with a psychiatric outpatient is about 8 to 15 minutes. We, therefore, examined whether repeated 15-minute psychotherapy sessions to improve patient assertiveness would be effective for reducing wrist cutting and possibly other forms of self-mutilation. We treated 13 patients diagnosed with borderline personality disorder and wrist-cutting syndrome with assertiveness training during 15-minute, biweekly therapy sessions over a course of one to four years. At the conclusion of psychotherapeutic treatment, 69% of outpatients showed a statistically significant reduction in wrist-cutting behavior.

  20. Postprandial Responses to Lipid and Carbohydrate Ingestion in Repeated Subcutaneous Adipose Tissue Biopsies in Healthy Adults

    Directory of Open Access Journals (Sweden)

    Aimee L. Dordevic

    2015-07-01

    Full Text Available Adipose tissue is a primary site of meta-inflammation. Diet composition influences adipose tissue metabolism and a single meal can drive an inflammatory response in postprandial period. This study aimed to examine the effect lipid and carbohydrate ingestion compared with a non-caloric placebo on adipose tissue response. Thirty-three healthy adults (age 24.5 ± 3.3 year (mean ± standard deviation (SD; body mass index (BMI 24.1 ± 3.2 kg/m2, were randomised into one of three parallel beverage groups; placebo (water, carbohydrate (maltodextrin or lipid (dairy-cream. Subcutaneous, abdominal adipose tissue biopsies and serum samples were collected prior to (0 h, as well as 2 h and 4 h after consumption of the beverage. Adipose tissue gene expression levels of monocyte chemoattractant protein-1 (MCP-1, interleukin 6 (IL-6 and tumor necrosis factor-α (TNF-α increased in all three groups, without an increase in circulating TNF-α. Serum leptin (0.6-fold, p = 0.03 and adipose tissue leptin gene expression levels (0.6-fold, p = 0.001 decreased in the hours following the placebo beverage, but not the nutrient beverages. Despite increased inflammatory cytokine gene expression in adipose tissue with all beverages, suggesting a confounding effect of the repeated biopsy method, differences in metabolic responses of adipose tissue and circulating adipokines to ingestion of lipid and carbohydrate beverages were observed.

  1. Evaluation of Histopathological Changes in Control Biopsies Which Taken 48 Sessions after NBUVB Phototherapy for Early-Stage Mycosis Fungoides

    Directory of Open Access Journals (Sweden)

    Ebru Zemheri

    2012-01-01

    Full Text Available Background. There are not many studies investigating histomorphological changes in 48 sessions in patients with early-stage MF after narrowband UVB (NBUVB treatment. Our purpose is to evaluate histological features of phototherapy after 48 sessions and determine which parameters are more reliable for controlling skin biopsies. Methods. Biopsies of 32 patients with early stage of MF, who were treated with NBUVB phototherapy, were histologically evaluated before and after the treatments, including epidermotropism, stratum corneum, epidermal thickness, dermal infiltration, papillary dermal fibrosis, vascular alterations, and other dermal changes. We discuss the histomorphological effects of NBUVB phototherapy on skin biopsies by comparing the responders with nonresponders, with before and after the treatment. Results. 9 patients (28% did not give any response to treatment. Alleviation in epidermotropism, increases in parakeratosis and normal keratosis, perivascular infiltration, and melanophages, decrease in the lichenoid/patchy lichenoid infiltration pattern after the treatment was statistically significant. Comparing by response, normalization of stratum corneum and epidermis, orthohyperkeratosis, decrease in linearly arranged cells, the lichenoid/patchy lichenoid infiltration, the loss of inflammation were statistically significant in responders group. Conclusion. We detected a significant decrease in linearly arranged cells after phototherapy, indicating that it is an “important diagnostic parameter" in evaluation of therapeutic response.

  2. Repeat biopsy in patients with initial diagnosis of PIN; La biopsia ripetuta nei pazienti con diagnosi iniziale di PIN

    Energy Technology Data Exchange (ETDEWEB)

    De Matteis, Massimo [Azienda Ospedaliera Policlinico S. Orsola-Malpighi, Bologna (Italy). UO Radiologia Albertoni; Poggi, Cristina; De Martino, Antonietta; Pavlica, Pietro [Azienda Ospedaliera Policlinico S. Orsola-Malpighi, Bologna (Italy). UO Radiologia Palagi, Dipartimento area radiologica; Corti, Barbara [Azienda Ospedaliera Policlinico S. Orsola-Malpighi, Bologna (Italy). UO Anatomia ed istologia patologica, Dipartimento oncologico ed ematologico; Barozzi, Libero [Azienda Ospedaliera Policlinico S. Orsola-Malpighi, Bologna (Italy). UO Radiologia d' urgenza, Dipartimento emergenze ed accettazione

    2005-09-15

    Purpose. Prostatic intra-epithelial neoplasia (PIN) is considered a pre-malignant lesion and the main precursor of invasive prostatic adenocarcinoma. A PIN diagnosis established by prostate needle biopsy poses a difficult clinical management. problem. We retrospectively reviewed our three-year experience in order to identify criteria for referring patients to repeat biopsy. Materials and methods. We reviewed the repeat biopsy records of 72 patients in whom PIN had been detected on initial US-guided needle biopsy of the prostate. All the patients had a minimum of 6 biopsy cores taken, and they all had PSA > 4 ng/ml. Results. Adenocarcinoma was detected in 15 patients out of 50 (30%) with an initial diagnosis of low-grade PIN and in 10 patients out of 22 (45.4%) with high grade PIN, in 7 out of 18 (39%) in whom PSA levels had decreased during the observation interval, in 16 patients out of 46 (35%) in whom the PSA had increased and in 2 patients out of 8 (25%) with stable PSA. Conclusions. Our results seem to confirm that PIN can be considered a precursor of prostatic adenocarcinoma or a histological alteration often associated with it. Patients with low-grade PIN and particularly those with high-grade PIN should be regularly subjected to repeat biopsy at short intervals due to the high frequency of the final diagnosis of carcinoma. No agreement has been reached on the time interval between the first and the second biopsy. The PSA changes during the observation period are not a statistically significant parameter to suggest the repetition of prostatic biopsy. [Italian] Scopo. La neoplasia prostatica intraepiteliale (PIN) e considerata una lesione premaligna ed il precursore principale dell'adenocarcinoma prostatico infiltrante. La diagnosi di PIN ottenuta con l'agobiopsia della prostata rappresenta un difficile problema gestionale clinico. In una valutazione retrospettiva della nostra esperienza di 3 anni si e cercato di individuare i criteri che possano

  3. Multiparametric MRI in men with clinical suspicion of prostate cancer undergoing repeat biopsy

    DEFF Research Database (Denmark)

    Boesen, Lars; Nørgaard, Nis; Løgager, Vibeke

    2018-01-01

    Background Multiparametric magnetic resonance imaging (mpMRI) can improve detection of clinically significant prostate cancer (csPCa). Purpose To compare mpMRI score subgroups to systematic transrectal ultrasound-guided biopsies (TRUSbx) and prostate-specific antigen (PSA)-based findings...

  4. Prognostic significance of repeat biopsy in lupus nephritis: Histopathologic worsening and a short time between biopsies is associated with significantly increased risk for end stage renal disease and death.

    Science.gov (United States)

    Arriens, Cristina; Chen, Sixia; Karp, David R; Saxena, Ramesh; Sambandam, Kamalanathan; Chakravarty, Eliza; James, Judith A; Merrill, Joan T

    2017-12-01

    Approximately half of patients with systemic lupus erythematosus (SLE) develop lupus nephritis (LN), a major cause of morbidity and early mortality in that disease. Prolonged renal inflammation is associated with irreversible kidney damage which confers a 30% risk of end stage renal disease (ESRD), making early, aggressive treatment mandatory. Failure to achieve therapeutic response or recurrence of renal flare often prompts repeat biopsy. However, the role of repeat biopsy in determining long-term renal prognosis remains controversial. For this reason repeat biopsies are usually not utilized unless clinical evidence of refractory or recurrent disease is already present, despite known mismatches between clinical and biopsy findings. The current study quantifies the degree to which histopathologic worsening between first and second biopsies and duration between them predicts ESRD and death. Medical records of 141 LN patients with more than one biopsy were obtained from a single large urban medical center. Cases were attained using billing codes for diagnosis and procedures from 1/1999-1/2015. Biopsy worsening was defined as unfavorable histopathologic classification transitions and/or increased chronicity; if neither were present, the patient was defined as non-worsening. We used Cox proportional hazard models to study the relationship between ESRD and survival adjusting for covariates which included age at first biopsy, gender, race, initial biopsy class, and initial induction therapy. Of 630 patients screened, 141 had more than one biopsy. Advancing chronicity was detected in 48 (34.0%) and a renal class switch to worse grade of pathology was found in 54 (38.3%). At least one of these adverse second biopsy features was reported in 79 (56.0%) patients. Five years following initial biopsy, 28 (35.4%) of those with worsening histopathology on second biopsy developed ESRD, compared to 6 (9.7%) of non-worsening patients and 10 (12.7%) of patients with worsening

  5. Intra-session repeatability of iridocorneal angle measurements provided by a Scheimpflug photography-based system in healthy eyes

    OpenAIRE

    Ruiz-Belda, Clara; Piñero, David P.; Ruiz Fortes, Pedro; Soto-Negro, Roberto; Moya, Myriam; Pérez Cambrodí, Rafael J.; Artola, Alberto

    2016-01-01

    Purpose: The purpose of this study was to evaluate intra-session repeatability of measurements of the iridocorneal angle at different meridians in the nasal and temporal areas in healthy eyes using the Sirius Scheimpflug photography-based system in glaucoma analysis mode. Methods: A total of 43 eyes of 43 patients ranging in age from 36 to 79 years were enrolled in the study. All eyes received a comprehensive ophthalmologic examination including a complete anterior segment analysis with the C...

  6. Repeated sessions of noninvasive brain DC stimulation is associated with motor function improvement in stroke patients.

    Science.gov (United States)

    Boggio, Paulo S; Nunes, Alice; Rigonatti, Sergio P; Nitsche, Michael A; Pascual-Leone, Alvaro; Fregni, Felipe

    2007-01-01

    Recent evidence has suggested that a simple technique of noninvasive brain stimulation - transcranial direct current stimulation (tDCS) - is associated with a significant motor function improvement in stroke patients. We tested the motor performance improvement in stroke patients following 4 weekly sessions of sham, anodal- and cathodal tDCS (experiment 1) and the effects of 5 consecutive daily sessions of cathodal tDCS (experiment 2). A blinded rater evaluated motor function using the Jebsen-Taylor Hand Function Test. There was a significant main effect of stimulation condition (p=0.009) in experiment 1. Furthermore there was a significant motor function improvement after either cathodal tDCS of the unaffected hemisphere (p=0.016) or anodal tDCS of the affected hemisphere (p=0.046) when compared to sham tDCS. There was no cumulative effect associated with weekly sessions of tDCS, however consecutive daily sessions of tDCS (experiment 2) were associated with a significant effect on time (pmotor function improvement in stroke patients; and support that consecutive daily sessions of tDCS might increase its behavioral effects. Because the technique of tDCS is simple, safe and non-expensive; our findings support further research on the use of this technique for the rehabilitation of patients with stroke.

  7. Dataset of acute repeated sessions of bifrontal transcranial direct current stimulation for treatment of intractable tinnitus: A randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Ali Yadollahpour

    2017-12-01

    Full Text Available Transcranial direct current stimulation (tDCS has reportedly shown promising therapeutic effects for tinnitus (Forogh et al., 2016; Joos et al., 2014 [1,2]. Studies are ongoing to determine optimum treatment protocol and the site of stimulation. Findings of the early studies are heterogeneous and most studies have focused on single session tDCS and short follow-up periods. There is no study on repeated sessions of tDCS with long term follow-up. This study presents the results of a randomized clinical trial investigating the therapeutic effects of acute multi-session tDCS over dorsolateral prefrontal cortex (DLPFC on tinnitus symptoms and comorbid depression and anxiety in patients with chronic intractable tinnitus. The dataset includes the demographic information, audiometric assessments, tinnitus specific characteristics, and the response variables of the study. The response variables included the scores of tinnitus handicap inventory (THI, tinnitus loudness and tinnitus related distress based on 0–10 numerical visual analogue scale (VAS scores, beck depression inventory (BDI-II and beck anxiety inventory (BAI scores. The dataset included the scores of THI pre and immediately post intervention, and at one month follow-up; the tinnitus loudness and distress scores prior to intervention, and immediately, one hour, one week, and at one month after the last stimulation session. In addition, the BDI-II, and BAI scores pre and post intervention are included. The data of the real (n=25 and sham tDCS (n=17 groups are reported. The main manuscript of this dataset is 'Acute repeated sessions of bifrontal transcranial direct current stimulation for treatment of intractable tinnitus: a randomized controlled trial' (Bayat et al., submitted for publication [3]. Keywords: Transcranial direct current stimulation, Acute stimulations, Tinnitus, Depression, Anxiety, DLPFC

  8. Affective Responses to Repeated Sessions of High-Intensity Interval Training.

    Science.gov (United States)

    Saanijoki, Tiina; Nummenmaa, Lauri; Eskelinen, Jari-Joonas; Savolainen, Anna M; Vahlberg, Tero; Kalliokoski, Kari K; Hannukainen, Jarna C

    2015-12-01

    Vigorous exercise feels unpleasant, and negative emotions may discourage adherence to regular exercise. We quantified the subjective affective responses to short-term high-intensity interval training (HIT) in comparison with moderate-intensity continuous training (MIT). Twenty-six healthy middle-age (mean age, 47 ± 5 yr; mean VO2peak, 34.2 ± 4.1 mL·kg⁻¹·min⁻¹) sedentary men were randomized into HIT (n = 13, 4-6 × 30 s of all-out cycling efforts at approximately 180% of peak workload with 4-min recovery) or MIT (n = 13, 40- to 60-min continuous cycling at 60% of peak workload) groups, performing six sessions within two weeks. Perceived exertion, stress, and affective state were recorded before, during, and after each session. Perceived exertion and arousal were higher, and affective state, more negative during the HIT than that during MIT sessions (P training. Peak oxygen consumption increased (P training). Short-term HIT and MIT are equally effective in improving aerobic fitness, but HIT increases experience of negative emotions and exertion in sedentary middle-age men. This may limit the adherence to this time-effective training mode, even though displeasure lessens over time and suggests similar mental adaptations to both MIT and HIT.

  9. Accuracy of 3 Tesla pelvic phased-array multiparametric MRI in diagnosing prostate cancer at repeat biopsy

    Directory of Open Access Journals (Sweden)

    Pietro Pepe

    2014-12-01

    Full Text Available Introduction. Multiparametric pelvic magnetic resonance imaging (mpMRI accuracy in prostate cancer (PCa diagnosis was evaluated. Materials and Methods. From June 2011 to December 2013, 168 patients (median 65 years with negative digital rectal examination underwent repeat transperineal saturation biopsy (SPBx; median 28 cores for persistently high or increasing PSA values, PSA >10 ng/ml or PSA values between 4.1-10 o r 2.6-4 ng/ml with free/total PSA < 25% and < 20%, respectively. All patients underwent mpMRI using a 3.0 Tesla scanner equipped with surface 16 channels phased-array coil and lesions suspicious for PCa were submitted to additional targeted biopsies. Results. A T1c PCa was found in 66 (39% cases; SPBx and mpMRI-suspicious targeted biopsy diagnosed 60 (91% and 52 (78.8% cancers missing 6 (all of the anterior zone and 14 cancers (12 and 2 of the lateral margins and anterior zone, respectively; in detail, mpMRI missed 12 (18.1% PCa charaterized by microfocal (1 positive core with greatest percentage of cancer and Gleason score equal to 5% and 6, respectively disease at risk for insignificant cancer. The diameter of the suspicious mpMRI lesion was directly correlated to the diagnosis of PCa with poor Gleason score (p < 0.05; detection rate of cancer for each suspicious mpMRI core was 35.3%. Diagnostic accuracy, sensitivity, specificity, positive and negative predictive value of mpMRI in diagnosing PCa was 75.7%, 82.5%, 71.8%, 78.9%, 87.9%, respectively. Conclusion. Multiparametric pMRI improved SPBx accuracy in diagnosing significant anterior PCa; the diameter of mpMRI suspicious lesion resulted significantly predictive of aggressive cancers.

  10. Use of the Prostate Core Mitomic Test in Repeated Biopsy Decision-Making: Real-World Assessment of Clinical Utility in a Multicenter Patient Population.

    Science.gov (United States)

    Legisi, Lorena; DeSa, Elise; Qureshi, M Nasar

    2016-12-01

    Prostate cancer is the most common cancer diagnosed in men in developed countries. Using molecular testing may help to improve outcomes in this clinically challenging group. Since 2011, the Prostate Core Mitomic Test (PCMT), which quantifies a 3.4-kb mitochondrial DNA deletion strongly associated with prostate cancer, has been used by more than 50 urology practices accessing pathology services through our laboratory in New Jersey. However, the use of a molecular test can only be beneficial if it affects patient management and improves outcomes. To determine whether repeated biopsy decision-making was affected in a quantifiable manner through the adjunct use of molecular testing with the PCMT. In this observational study we conducted 2 independent, structured query language database queries of our patient records at our laboratory, QDx Pathology Services, in Cranford, NJ. Query 1 included all men who had a negative prostate biopsy and a negative PCMT between February 1, 2011, and June 30, 2013. Men with a previous diagnosis of cancer were excluded. Query 2 included all men who had a negative prostate biopsy and a repeated biopsy between February 1, 2011, and September 30, 2013. The data exported for each query included the unique specimen number for an index biopsy, the interval between biopsies where present, the unique specimen number for a follow-up biopsy where present, histopathology for all biopsies, the biopsy procedure dates, the patient's date of birth, and the PCMT result when utilized. The patient rebiopsy rates and intervals were compared between the patients who were using PCMT and those who were not to assess whether the adjunct use of the PCMT impacted the rebiopsy decision-making process. Query 1 identified 644 men who had a negative biopsy and a negative PCMT result within the study period. Query 2 identified 823 men with a repeat biopsy after the initial negative index biopsy within the study period. Of these men, 132 had PCMT to inform their care

  11. The repeated bout effect of typical lower body strength training sessions on sub-maximal running performance and hormonal response.

    Science.gov (United States)

    Doma, Kenji; Schumann, Moritz; Sinclair, Wade H; Leicht, Anthony S; Deakin, Glen B; Häkkinen, Keijo

    2015-08-01

    This study examined the effects of two typical strength training sessions performed 1 week apart (i.e. repeated bout effect) on sub-maximal running performance and hormonal. Fourteen resistance-untrained men (age 24.0 ± 3.9 years; height 1.83 ± 0.11 m; body mass 77.4 ± 14.0 kg; VOpeak 48.1 ± 6.1 M kg(-1) min(-1)) undertook two bouts of high-intensity strength training sessions (i.e. six-repetition maximum). Creatine kinase (CK), delayed-onset muscle soreness (DOMS), counter-movement jump (CMJ) as well as concentrations of serum testosterone, cortisol and testosterone/cortisol ratio (T/C) were examined prior to and immediately post, 24 (T24) and 48 (T48) h post each strength training bout. Sub-maximal running performance was also conducted at T24 and T48 of each bout. When measures were compared between bouts at T48, the degree of elevation in CK (-58.4 ± 55.6 %) and DOMS (-31.43 ± 42.9 %) and acute reduction in CMJ measures (4.1 ± 5.4 %) were attenuated (p 0.05). Sub-maximal running performance was impaired until T24, although changes were not attenuated following the second bout. The initial bout appeared to provide protection against a number of muscle damage indicators suggesting a greater need for recovery following the initial session of typical lower body resistance exercises in resistance-untrained men although sub-maximal running should be avoided following the first two sessions.

  12. A four-kallikrein panel for the prediction of repeat prostate biopsy: data from the European Randomized Study of Prostate Cancer screening in Rotterdam, Netherlands.

    Science.gov (United States)

    Gupta, A; Roobol, M J; Savage, C J; Peltola, M; Pettersson, K; Scardino, P T; Vickers, A J; Schröder, F H; Lilja, H

    2010-08-24

    Most men with elevated levels of prostate-specific antigen (PSA) do not have prostate cancer, leading to a large number of unnecessary biopsies. A statistical model based on a panel of four kallikreins has been shown to predict the outcome of a first prostate biopsy. In this study, we apply the model to an independent data set of men with previous negative biopsy but persistently elevated PSA. The study cohort consisted of 925 men with a previous negative prostate biopsy and elevated PSA (>or=3 ng ml(-1)), with 110 prostate cancers detected (12%). A previously published statistical model was applied, with recalibration to reflect the lower positive biopsy rates on rebiopsy. The full-kallikrein panel had higher discriminative accuracy than PSA and DRE alone, with area under the curve (AUC) improving from 0.58 (95% confidence interval (CI): 0.52, 0.64) to 0.68 (95% CI: 0.62, 0.74), Por=7) at biopsy with AUC improving from 0.76 (95% CI: 0.64, 0.89) to 0.87 (95% CI: 0.81, 0.94), P=0.003). Application of the panel to 1000 men with persistently elevated PSA after initial negative biopsy, at a 15% risk threshold would reduce the number of biopsies by 712; would miss (or delay) the diagnosis of 53 cancers, of which only 3 would be Gleason 7 and the rest Gleason 6 or less. Our data constitute an external validation of a previously published model. The four-kallikrein panel predicts the result of repeat prostate biopsy in men with elevated PSA while dramatically decreasing unnecessary biopsies.

  13. The Effect of Transcranial Direct Current Stimulation (tDCS) Electrode Size and Current Intensity on Motor Cortical Excitability: Evidence From Single and Repeated Sessions.

    Science.gov (United States)

    Ho, Kerrie-Anne; Taylor, Janet L; Chew, Taariq; Gálvez, Verònica; Alonzo, Angelo; Bai, Siwei; Dokos, Socrates; Loo, Colleen K

    2016-01-01

    Current density is considered an important factor in determining the outcomes of tDCS, and is determined by the current intensity and electrode size. Previous studies examining the effect of these parameters on motor cortical excitability with small sample sizes reported mixed results. This study examined the effect of current intensity (1 mA, 2 mA) and electrode size (16 cm(2), 35 cm(2)) on motor cortical excitability over single and repeated tDCS sessions. Data from seven studies in 89 healthy participants were pooled for analysis. Single-session data were analyzed using mixed effects models and repeated-session data were analyzed using mixed design analyses of variance. Computational modeling was used to examine the electric field generated. The magnitude of increases in excitability after anodal tDCS was modest. For single-session tDCS, the 35 cm(2) electrodes produced greater increases in cortical excitability compared to the 16 cm(2) electrodes. There were no differences in the magnitude of cortical excitation produced by 1 mA and 2 mA tDCS. The repeated-sessions data also showed that there were greater increases in excitability with the 35 cm(2) electrodes. Further, repeated sessions of tDCS with the 35 cm(2) electrodes resulted in a cumulative increase in cortical excitability. Computational modeling predicted higher electric field at the motor hotspot for the 35 cm(2) electrodes. 2 mA tDCS does not necessarily produce larger effects than 1 mA tDCS in healthy participants. Careful consideration should be given to the exact positioning, size and orientation of tDCS electrodes relative to cortical regions. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Cost-effectiveness analysis of repeat fine-needle aspiration for thyroid biopsies read as atypia of undetermined significance.

    Science.gov (United States)

    Heller, Michael; Zanocco, Kyle; Zydowicz, Sara; Elaraj, Dina; Nayar, Ritu; Sturgeon, Cord

    2012-09-01

    The 2007 National Cancer Institute (NCI) conference on Thyroid Fine-Needle Aspiration (FNA) introduced the category atypia of undetermined significance (AUS) or follicular lesion of undetermined significance (FLUS). Repeat FNA in 3 to 6 months was recommended for low-risk patients. Compliance with these recommendations has been suboptimal. We hypothesized that repeat FNA would be more effective than diagnostic lobectomy, with decreased costs and improved rates of cancer detection. Cost-effectiveness analysis was performed in which we compared diagnostic lobectomy with repeat FNA. A Markov model was developed. Outcomes and probabilities were identified from literature review. Third-party payer costs were estimated in 2010 US dollars. Outcomes were weighted by use of the quality-of-life utility factors, yielding quality-adjusted life years (QALYs). Monte Carlo simulation and sensitivity analysis were used to examine the uncertainty of probability, cost, and utility estimates. The diagnostic lobectomy strategy cost $8,057 and produced 23.99 QALYs. Repeat FNA cost $2,462 and produced 24.05 QALYs. Repeat FNA was dominant until the cost of FNA increased to $6,091. Dominance of the repeat FNA strategy was not sensitive to the cost of operation or the complication rate. The NCI recommendations for repeat FNA regarding follow-up of AUS/FLUS results are cost-effective. Improving compliance with these guidelines should lead to less overall costs, greater quality of life, and fewer unnecessary operations. Copyright © 2012 Mosby, Inc. All rights reserved.

  15. The PCA3 test for guiding repeat biopsy of prostate cancer and its cut-off score: a systematic review and meta-analysis

    Directory of Open Access Journals (Sweden)

    Yong Luo

    2014-06-01

    Full Text Available The specificity of prostate-specific antigen (PSA for early intervention in repeat biopsy is unsatisfactory. Prostate cancer antigen 3 (PCA3 may be more accurate in outcome prediction than other methods for the early detection of prostate cancer (PCa. However, the results were inconsistent in repeated biopsies. Therefore, we performed a systematic review and meta-analysis to evaluate the role of PCA3 in outcome prediction. A systematic bibliographic search was conducted for articles published before April 2013, using PubMed, Medline, Web of Science, Embase and other databases from health technology assessment agencies. The quality of the studies was assessed on the basis of QUADAS criteria. Eleven studies of diagnostic tests with moderate to high quality were selected. A meta-analysis was carried out to synthesize the results. The results of the meta-analyses were heterogeneous among studies. We performed a subgroup analysis (with or without inclusion of high-grade prostatic intraepithelial neoplasia (HGPIN and atypical small acinar proliferation (ASAP. Using a PCA3 cutoff of 20 or 35, in the two sub-groups, the global sensitivity values were 0.93 or 0.80 and 0.79 or 0.75, specificities were 0.65 or 0.44 and 0.78 or 0.70, positive likelihood ratios were 1.86 or 1.58 and 2.49 or 1.78, negative likelihood ratios were 0.81 or 0.43 and 0.91 or 0.82 and diagnostic odd ratios (ORs were 5.73 or 3.45 and 7.13 or 4.11, respectively. The areas under the curve (AUCs of the summary receiver operating characteristic curve were 0.85 or 0.72 and 0.81 or 0.69, respectively. PCA3 can be used for repeat biopsy of the prostate to improve accuracy of PCa detection. Unnecessary biopsies can be avoided by using a PCa cutoff score of 20.

  16. Prostate cancer detection rate in patients with fluctuating prostate-specific antigen levels on the repeat prostate biopsy

    Directory of Open Access Journals (Sweden)

    Yong Hyun Park

    2014-03-01

    Conclusions: The current study shows that the risk of prostate cancer at repeat TRUS-Bx was higher in men with a fluctuating PSA level and PSAV=1.0 ng/mL/yr than in those with a fluctuating PSA level and PSAV<1.0 ng/mL/yr.

  17. Prospective comparison of T2w-MRI and dynamic-contrast-enhanced MRI, 3D-MR spectroscopic imaging or diffusion-weighted MRI in repeat TRUS-guided biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Portalez, Daniel [Clinique Pasteur, 45, Department of Radiology, Toulouse (France); Rollin, Gautier; Mouly, Patrick; Jonca, Frederic; Malavaud, Bernard [Hopital de Rangueil, Department of Urology, Toulouse Cedex 9 (France); Leandri, Pierre [Clinique Saint Jean, 20, Department of Urology, Toulouse (France); Elman, Benjamin [Clinique Pasteur, 45, Department of Urology, Toulouse (France)

    2010-12-15

    To compare T2-weighted MRI and functional MRI techniques in guiding repeat prostate biopsies. Sixty-eight patients with a history of negative biopsies, negative digital rectal examination and elevated PSA were imaged before repeat biopsies. Dichotomous criteria were used with visual validation of T2-weighted MRI, dynamic contrast-enhanced MRI and literature-derived cut-offs for 3D-spectroscopy MRI (choline-creatine-to-citrate ratio >0.86) and diffusion-weighted imaging (ADC x 10{sup 3} mm{sup 2}/s < 1.24). For each segment and MRI technique, results were rendered as being suspicious/non-suspicious for malignancy. Sextant biopsies, transition zone biopsies and at least two additional biopsies of suspicious areas were taken. In the peripheral zones, 105/408 segments and in the transition zones 19/136 segments were suspicious according to at least one MRI technique. A total of 28/68 (41.2%) patients were found to have cancer. Diffusion-weighted imaging exhibited the highest positive predictive value (0.52) compared with T2-weighted MRI (0.29), dynamic contrast-enhanced MRI (0.33) and 3D-spectroscopy MRI (0.25). Logistic regression showed the probability of cancer in a segment increasing 12-fold when T2-weighted and diffusion-weighted imaging MRI were both suspicious (63.4%) compared with both being non-suspicious (5.2%). The proposed system of analysis and reporting could prove clinically relevant in the decision whether to repeat targeted biopsies. (orig.)

  18. Gait Deviation Index, Gait Profile Score and Gait Variable Score in children with spastic cerebral palsy: Intra-rater reliability and agreement across two repeated sessions.

    Science.gov (United States)

    Rasmussen, Helle Mätzke; Nielsen, Dennis Brandborg; Pedersen, Niels Wisbech; Overgaard, Søren; Holsgaard-Larsen, Anders

    2015-07-01

    The Gait Deviation Index (GDI) and Gait Profile Score (GPS) are the most used summary measures of gait in children with cerebral palsy (CP). However, the reliability and agreement of these indices have not been investigated, limiting their clinimetric quality for research and clinical practice. The aim of this study was to investigate the intra-rater reliability and agreement of summary measures of gait (GDI; GPS; and the Gait Variable Score (GVS) derived from the GPS). The intra-rater reliability and agreement were investigated across two repeated sessions in 18 children aged 5-12 years diagnosed with spastic CP. No systematic bias was observed between the sessions and no heteroscedasticity was observed in Bland-Altman plots. For the GDI and GPS, excellent reliability with intraclass correlation coefficient (ICC) values of 0.8-0.9 was found, while the GVS was found to have fair to good reliability with ICCs of 0.4-0.7. The agreement for the GDI and the logarithmically transformed GPS, in terms of the standard error of measurement as a percentage of the grand mean (SEM%) varied from 4.1 to 6.7%, whilst the smallest detectable change in percent (SDC%) ranged from 11.3 to 18.5%. For the logarithmically transformed GVS, we found a fair to large variation in SEM% from 7 to 29% and in SDC% from 18 to 81%. The GDI and GPS demonstrated excellent reliability and acceptable agreement proving that they can both be used in research and clinical practice. However, the observed large variability for some of the GVS requires cautious consideration when selecting outcome measures. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Repeat prostate-specific antigen (PSA) test before prostate biopsy: a 20% decrease in PSA values is associated with a reduced risk of cancer and particularly of high-grade cancer.

    Science.gov (United States)

    De Nunzio, Cosimo; Lombardo, Riccardo; Nacchia, Antonio; Tema, Giorgia; Tubaro, Andrea

    2018-07-01

    To analyse the impact of repeating a prostate-specific antigen (PSA) level assessment on prostate biopsy decision in a cohort of men undergoing prostate biopsy. From 2015 onwards, we consecutively enrolled, at a single institution in Italy, men undergoing 12-core transrectal ultrasonography-guided prostate needle biopsy. Indication for prostate biopsy was a PSA level of ≥4 ng/mL. Demographic, clinical, and histopathological data were collected. The PSA level was tested at enrolment (PSA 1 ) and 4 weeks later on the day before biopsy (PSA 2 ). Variations in PSA level were defined as: stable PSA 2 within a 10% variation, stable PSA 2 within a 20% variation, PSA 2 decreased by ≥10%, PSA 2 decreased by ≥20%, PSA 2 increased by ≥10%, PSA 2 increased by ≥20%, and PSA 2 PSA within 20% variation had a higher risk of prostate cancer (odds ratio [OR] 1.80, P PSA2 decreased by ≥20% had a lower risk of prostate cancer (OR 0.37, P PSA2 increased by ≥10% had an increased risk of high-grade prostate cancer (OR 1.93, P PSA returned to normal values (PSA levels significantly reduced the risk of high-grade prostate cancer. Further multicentre studies should validate our present results. © 2018 The Authors BJU International © 2018 BJU International Published by John Wiley & Sons Ltd.

  20. Liver biopsy

    Science.gov (United States)

    Biopsy - liver; Percutaneous biopsy ... the biopsy needle to be inserted into the liver. This is often done by using ultrasound. The ... the chance of damage to the lung or liver. The needle is removed quickly. Pressure will be ...

  1. Prostate health index and prostate cancer gene 3 score but not percent-free Prostate Specific Antigen have a predictive role in differentiating histological prostatitis from PCa and other nonneoplastic lesions (BPH and HG-PIN) at repeat biopsy.

    Science.gov (United States)

    De Luca, Stefano; Passera, Roberto; Fiori, Cristian; Bollito, Enrico; Cappia, Susanna; Mario Scarpa, Roberto; Sottile, Antonino; Franco Randone, Donato; Porpiglia, Francesco

    2015-10-01

    To determine if prostate health index (PHI), prostate cancer antigen gene 3 (PCA3) score, and percentage of free prostate-specific antigen (%fPSA) may be used to differentiate asymptomatic acute and chronic prostatitis from prostate cancer (PCa), benign prostatic hyperplasia (BPH), and high-grade prostate intraepithelial neoplasia (HG-PIN) in patients with elevated PSA levels and negative findings on digital rectal examination at repeat biopsy (re-Bx). In this prospective study, 252 patients were enrolled, undergoing PHI, PCA3 score, and %fPSA assessments before re-Bx. We used 3 multivariate logistic regression models to test the PHI, PCA3 score, and %fPSA as risk factors for prostatitis vs. PCa, vs. BPH, and vs. HG-PIN. All the analyses were performed for the whole patient cohort and for the "gray zone" of PSA (4-10ng/ml) cohort (171 individuals). Of the 252 patients, 43 (17.1%) had diagnosis of PCa. The median PHI was significantly different between men with a negative biopsy and those with a positive biopsy (34.9 vs. 48.1, Pprostatitis and PCa was moderate, although it extended to a good range of threshold probabilities (40%-100%), whereas that from using %fPSA was negligible: this pattern was reported for the whole population as for the "gray zone" PSA cohort. In front of a good diagnostic performance of all the 3 biomarkers in distinguishing negative biopsy vs. positive biopsy, the clinical benefit of using the PCA3 score and PHI to estimate prostatitis vs. PCa was comparable. PHI was the only determinant for prostatitis vs. BPH, whereas no biomarkers could differentiate prostate inflammation from HG-PIN. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Prostate biopsy

    Science.gov (United States)

    ... give the cells a grade called a Gleason score . This helps predict how fast the cancer will ... TRUS); Stereotactic transperineal prostate biopsy (STPB) Images Male reproductive anatomy References Babayan RK, Katz MH. Biopsy prophylaxis, ...

  3. Kidney biopsy

    Science.gov (United States)

    ... the kidney (in rare cases, may require a blood transfusion) Bleeding into the muscle, which might cause soreness Infection (small risk) Alternative Names Renal biopsy; Biopsy - kidney Images Kidney anatomy ...

  4. Liver biopsy under hypnosis.

    Science.gov (United States)

    Adams, P C; Stenn, P G

    1992-09-01

    Two patients underwent outpatient percutaneous liver biopsy under hypnosis without complications. One patient had severe anxiety about the procedure because of a previous adverse experience with liver biopsy and the other had a history of severe allergy to local anesthesia. Both patients had undergone a session of hypnosis at least once prior to the biopsy. One received no local anesthetic and the other received 1% lidocaine as a local anesthetic. Both patients were completely cooperative during the procedure with the required respiratory maneuvers. Both patients stated that they were aware of the procedure under hypnosis but described no pain and would be most willing to have the procedure done under hypnosis in the future. Hypnosis can be a useful method of preparing carefully selected patients for percutaneous liver biopsy.

  5. The influence of prostate-specific antigen density on positive and negative predictive values of multiparametric magnetic resonance imaging to detect Gleason score 7-10 prostate cancer in a repeat biopsy setting.

    Science.gov (United States)

    Hansen, Nienke L; Barrett, Tristan; Koo, Brendan; Doble, Andrew; Gnanapragasam, Vincent; Warren, Anne; Kastner, Christof; Bratt, Ola

    2017-05-01

    To evaluate the influence of prostate-specific antigen density (PSAD) on positive (PPV) and negative (NPV) predictive values of multiparametric magnetic resonance imaging (mpMRI) to detect Gleason score ≥7 cancer in a repeat biopsy setting. Retrospective study of 514 men with previous prostate biopsy showing no or Gleason score 6 cancer. All had mpMRI, graded 1-5 on a Likert scale for cancer suspicion, and subsequent targeted and 24-core systematic image-fusion guided transperineal biopsy in 2013-2015. The NPVs and PPVs of mpMRIs for detecting Gleason score ≥7 cancer were calculated (±95% confidence intervals) for PSAD ≤0.1, 0.1-0.2, ≤0.2 and >0.2 ng/mL/mL, and compared by chi-square test for linear trend. Gleason score ≥7 cancer was detected in 31% of the men. The NPV of Likert 1-2 mpMRI was 0.91 (±0.04) with a PSAD of ≤0.2 ng/mL/mL and 0.71 (±0.16) with a PSAD of >0.2 ng/mL/mL (P = 0.003). For Likert 3 mpMRI, PPV was 0.09 (±0.06) with a PSAD of ≤0.2 ng/mL/mL and 0.44 (±0.19) with a PSAD of >0.2 ng/mL/mL (P = 0.002). PSAD also significantly affected the PPV of Likert 4-5 mpMRI lesions: the PPV was 0.47 (±0.08) with a PSAD of ≤0.2 ng/mL/mL and 0.66 (±0.10) with a PSAD of >0.2 ng/mL/mL (P prostate cancer, not only in men with negative mpMRI, but also in men with equivocal imaging. Surveillance, rather than repeat biopsy, may be appropriate for these men. Conversely, biopsies are indicated in men with a high PSAD, even if an mpMRI shows no suspicious lesion, and in men with an mpMRI suspicious for cancer, even if the PSAD is low. © 2016 The Authors BJU International © 2016 BJU International Published by John Wiley & Sons Ltd.

  6. Preimplantation diagnosis of repeated miscarriage due to chromosomal translocations using metaphase chromosomes of a blastomere biopsied from 4- to 6-cell-stage embryos.

    Science.gov (United States)

    Tanaka, Atsushi; Nagayoshi, Motoi; Awata, Shoichiro; Mawatari, Yoshifumi; Tanaka, Izumi; Kusunoki, Hiroshi

    2004-01-01

    To evaluate the safety and accuracy of karyotyping the blastomere chromosomes at metaphase in the natural cell cycle for preimplantation diagnosis. A pilot study. A private infertility clinic and a university laboratory. Eleven patients undergoing IVF and preimplantation diagnosis. Intact human embryos at the 4- to 6-cell stage and human-mouse heterokaryons were cultured and checked hourly for disappearance of the nuclear envelope. After it disappeared, the metaphase chromosomes were analyzed by fluorescence in situ hybridization. Percentage of analyzable metaphase plates and safety and accuracy of the method. The success rate of electrofusion to form human-mouse heterokaryons was 87.1% (27/31), and analyzable chromosomes were obtained from 77.4% (24/31) of the heterokaryons. On the other hand, disappearance of the nuclear envelope occurred in 89.5% (17/19) of the human embryos and it began earlier than that in the heterokaryons. Analyzable chromosomes were obtained and their translocation sites were identified in all blastomeres biopsied from the 17 embryos. After the biopsy, 67.0% of the embryos could develop to the blastocyst stage. The natural cell cycle method reported herein requires frequent observation, but it is safe, with no artificial effects on the chromosomes and without loss of or damage to blastomeres, which occurred with the electrofusion method. Using the natural cell cycle method, we could perform preimplantation diagnosis with nearly 100% accuracy.

  7. Comparison of initial and tertiary centre second opinion reads of multiparametric magnetic resonance imaging of the prostate prior to repeat biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, Nienke L. [University Hospital RWTH Aachen, Department of Diagnostic and Interventional Radiology, Aachen (Germany); Addenbrooke' s Hospital and University of Cambridge, CamPARI Clinic, Cambridge (United Kingdom); Koo, Brendan C.; Gallagher, Ferdia A. [Addenbrooke' s Hospital and University of Cambridge, CamPARI Clinic, Cambridge (United Kingdom); Addenbrooke' s Hospital and University of Cambridge, Department of Radiology, Cambridge (United Kingdom); Warren, Anne Y. [Addenbrooke' s Hospital and University of Cambridge, CamPARI Clinic, Cambridge (United Kingdom); Addenbrooke' s Hospital, Department of Pathology, Cambridge (United Kingdom); Doble, Andrew; Gnanapragasam, Vincent; Bratt, Ola; Kastner, Christof [Addenbrooke' s Hospital and University of Cambridge, CamPARI Clinic, Cambridge (United Kingdom); Addenbrooke' s Hospital, Department of Urology, Cambridge (United Kingdom); Barrett, Tristan [Addenbrooke' s Hospital and University of Cambridge, CamPARI Clinic, Cambridge (United Kingdom); Addenbrooke' s Hospital and University of Cambridge, Department of Radiology, Cambridge (United Kingdom); University of Cambridge School of Clinical Medicine, Department of Radiology, Box 218, Cambridge (United Kingdom)

    2017-06-15

    To investigate the value of second-opinion evaluation of multiparametric prostate magnetic resonance imaging (MRI) by subspecialised uroradiologists at a tertiary centre for the detection of significant cancer in transperineal fusion prostate biopsy. Evaluation of prospectively acquired initial and second-opinion radiology reports of 158 patients who underwent MRI at regional hospitals prior to transperineal MR/untrasound fusion biopsy at a tertiary referral centre over a 3-year period. Gleason score (GS) 7-10 cancer, positive predictive value (PPV) and negative (NPV) predictive value (±95 % confidence intervals) were calculated and compared by Fisher's exact test. Disagreement between initial and tertiary centre second-opinion reports was observed in 54 % of cases (86/158). MRIs had a higher NPV for GS 7-10 in tertiary centre reads compared to initial reports (0.89 ± 0.08 vs 0.72 ± 0.16; p = 0.04), and a higher PPV in the target area for all cancer (0.61 ± 0.12 vs 0.28 ± 0.10; p = 0.01) and GS 7-10 cancer (0.43 ± 0.12 vs 0.2 3 ± 0.09; p = 0.02). For equivocal suspicion, the PPV for GS 7-10 was 0.12 ± 0.11 for tertiary centre and 0.11 ± 0.09 for initial reads; p = 1.00. Second readings of prostate MRI by subspecialised uroradiologists at a tertiary centre significantly improved both NPV and PPV. Reporter experience may help to reduce overcalling and avoid overtargeting of lesions. (orig.)

  8. Cold knife cone biopsy

    Science.gov (United States)

    ... biopsy; Pap smear - cone biopsy; HPV - cone biopsy; Human papilloma virus - cone biopsy; Cervix - cone biopsy; Colposcopy - cone biopsy Images Female reproductive anatomy Cold cone biopsy Cold cone removal References Baggish ...

  9. Closing session

    International Nuclear Information System (INIS)

    2014-01-01

    This part makes a summary of the different sessions and discussions of the workshop in a series of slide presentations: Summary of Opening Session; Summary of Session 1: Analysis of External Hazard Potential; Summary of session 2: Specific features of analysis and modeling of particular natural external hazards; Summary of session-3: Practices and research efforts on natural external events PSA; Summary of session 4: Modeling of NPP response to natural external events in PSA; Summary of session 5: Seismic Risk Analysis; Summary of session 6: Use of external events PSA with the focus on regulatory body role; Facilitated discussion 1 summary: Where do we stand in the analysis of external events?; Summary Facilitated Discussion 2: Findings and Good Practices for External Events Analysis

  10. Liver Biopsy

    Science.gov (United States)

    ... called if any of the following occur: ● Persistent abdominal or chest pain ● Vomiting ● Pallor, weakness or dizziness ● Bleeding from the site of the biopsy ● Passage of tarry black stools For more information or to locate a pediatric gastroen- terologist in your area please visit our ...

  11. Panel Session

    DEFF Research Database (Denmark)

    Bertelsen, Olav Wedege

    2004-01-01

    In this panel session, four researchers will discuss the role of a theoretical foundation, in particular AT, in the design of information technology based artefacts. The general discussion will take of from a specific examination of the ActAD approach.......In this panel session, four researchers will discuss the role of a theoretical foundation, in particular AT, in the design of information technology based artefacts. The general discussion will take of from a specific examination of the ActAD approach....

  12. Oropharynx lesion biopsy

    Science.gov (United States)

    ... as papilloma) Fungal infections (such as candida) Histoplasmosis Oral lichen planus Precancerous sore (leukoplakia) Viral infections (such as Herpes simplex) Risks Risks of the procedure may ... Throat lesion biopsy; Biopsy - mouth or throat; Mouth lesion biopsy; Oral cancer - biopsy ...

  13. Image guided versus palpation guided core needle biopsy of palpable breast masses: a prospective study

    Directory of Open Access Journals (Sweden)

    Smriti Hari

    2016-01-01

    Interpretation & conclusions: Our results showed that in palpable breast masses, image guided biopsy was superior to palpation guided biopsy in terms of sensitivity, false negative rate and repeat biopsy rates.

  14. Stereotactic breast biopsy with a biopsy gun

    International Nuclear Information System (INIS)

    Parker, S.H.; Lovin, J.; Luethke, J.; Jobe, W.E.; Hopper, K.D.; Yakes, W.F.

    1989-01-01

    With the recent introduction of stereotactic mammographic localizing devices, the authors have been performing histologic core needle breast biopsies in which the Bard biopsy gun is used in conjunction with sterotactic guidance. The authors have performed 60 breast gun biopsies with 16-gauge and 18-gauge biopsy-cut needles. These biopsies were followed immediately by traditional surgical excision. Pathologic results correlated well in 52 of the 60 patients, including 10 of 13 cancers. Three of the eight negative correlations occurred when diagnosis was made on gun biopsy but not on surgical biopsy. The stereotactic- guided gun biopsies appear to approach the surgical gold standard, decrease patient discomfort and potential disfigurement, lower the cost of breast biopsy, and lower the threshold necessary to perform breast biopsy

  15. ESPR uroradiology task force and ESUR Paediatric Work Group--Imaging recommendations in paediatric uroradiology, part VI: childhood renal biopsy and imaging of neonatal and infant genital tract. Minutes from the task force session at the annual ESPR Meeting 2012 in Athens on childhood renal biopsy and imaging neonatal genitalia.

    Science.gov (United States)

    Riccabona, Michael; Lobo, Maria Luisa; Willi, Ulrich; Avni, Fred; Damasio, Beatrice; Ording-Mueller, Lil-Sofie; Blickman, Johan; Darge, Kassa; Papadopoulou, Frederika; Vivier, Pierre-Hugues

    2014-04-01

    The European Society of Paediatric Radiology Uroradiology Task Force and the ESUR Paediatric Work Group jointly publish guidelines for paediatric urogenital imaging. Two yet unaddressed topics involving patient safety and imaging load are addressed in this paper: renal biopsy in childhood and imaging of the neonatal genital tract, particularly in girls. Based on our thorough review of literature and variable practice in multiple centers, procedural recommendations are proposed on how to perform renal biopsy in children and how to approach the genital tract in (female) neonates. These are statements by consensus due to lack of sufficient evidence-based data. The procedural recommendation on renal biopsy in childhood aims at improving patient safety and reducing the number of unsuccessful passes and/or biopsy-related complications. The recommendation for an imaging algorithm in the assessment of the neonatal genital tract focuses on the potential of ultrasonography to reduce the need for more invasive or radiating imaging, however, with additional fluoroscopy or MRI to be used in selected cases. Adherence to these recommendations will allow comparable data and evidence to be generated for future adaptation of imaging strategies in paediatric uroradiology.

  16. Breakout Sessions

    CERN Multimedia

    CERN. Geneva

    2004-01-01

    Participants are split into small groups for detailed discussion on their chosen topic. To register please click on 'See details' link from the agenda and then on the link to send an email to the session for which you would like to book. Please don't change the subject line of the email.

  17. Stereotactic biopsy

    International Nuclear Information System (INIS)

    Mwangi, M.N.; Handa, A.

    2006-01-01

    This technology is capable of locating lesions precise detected by the mammography examinations. This devise allows the surgeon to position automatically the needle to perform the cytological/histological biopsy with maximum position accuracy. This is under sterile procedure. to position the lesion in the beam, two radiographic procedures are carried out: the first with the X-ray beam at an inclination of -15 degrees with respect to the position 0 degrees and the second at the inclination +15 degrees. After processing the film the lesion will appear on both radiographs but on light are of the negatoscope. With the cursor information is fed from four points. On the display the length of the needle will appear immediately. The length of the needle to be used in suction is chosen on the basis of the two values on the display. This information fed on the control panel will move the needle unit position where the lesion is. the needle is then introduced under local anaesthesia at the preselected length until it clicks into position. An exposure is made with needle in situ in position at +15 degrees and -15 degrees to ensure the needle is in position. the suction is then carried out and the needle removed. The machine is then reset to return at the initial position

  18. When size matters: diagnostic value of kidney biopsy according to the gauge of the biopsy needle.

    Science.gov (United States)

    Roth, Rachel; Parikh, Samir; Makey, Dayanand; Foster, Jamison; Rozenblit, Grigory; Satoskar, Anjali; Nadasdy, Gyongyi; Von Visger, Jon; Hebert, Lee; Rovin, Brad H; Nadasdy, Tibor; Brodsky, Sergey V

    2013-01-01

    Kidney biopsy is a vital tool in the diagnosis of kidney disease. Although it has become a routine procedure, it is not complication-free. Some serious complications of percutaneous kidney biopsy include retroperitoneal hemorrhage and death. There is an increased belief that smaller biopsy needle size results in a lower complication rate. As renal pathologists, we witness an increased number of kidney biopsies performed with a small needle size (as low as gauge 22), which results in inadequate tissue sampling and often non-diagnostic biopsy results. Herein we report the diagnostic value of kidney biopsies according to the size of the biopsy needles. We performed kidney biopsies from nephrectomy specimens using biopsy needles of different sizes. Morphologic parameters were analyzed. We found that biopsies performed by small needles (gauges 20 and 22) contain significantly lower numbers of glomeruli and blood vessels, which limits pathologic evaluation. Data from our institution do not show differences in kidney biopsy complication rates between 16- and 18-gauge needles. Our data indicate that small biopsy needles do not provide sufficient material for diagnosis, and they increase the likelihood for a repeat biopsy. Copyright © 2013 S. Karger AG, Basel.

  19. Open lung biopsy

    Science.gov (United States)

    Biopsy - open lung ... An open lung biopsy is done in the hospital using general anesthesia . This means you will be asleep and ... The open lung biopsy is done to evaluate lung problems seen on x-ray or CT scan .

  20. Bone lesion biopsy

    Science.gov (United States)

    Bone biopsy; Biopsy - bone ... the cut, then pushed and twisted into the bone. Once the sample is obtained, the needle is ... sample is sent to a lab for examination. Bone biopsy may also be done under general anesthesia ...

  1. Biopsy system for CT-guided biopsies

    International Nuclear Information System (INIS)

    Onik, G.; Cosman, E.; Wells, T.; Goldberg, H.I.; Moss, A.; Costello, P.; Kane, R.

    1987-01-01

    CT stereotaxic brain biopsies have made brain biopsies safe and minimally invasive. CT-guided biopsies of the body, however, have traditionally used a hand-guidance method. CT biopsy guidance systems for the body have recently become available that have similar capabilities as those of brain biopsy systems. To compare the clinical utility of stereotaxically guided biopsies with hand-guided biopsies, the authors prospectively compared 40 biopsies performed with each method. In the stereotaxic method, a localizor grid was placed on the patient to define a reference point, and a frame was used to guide the needle along the intended path. Computer software programs calculated complex paths from one scan plane to another. Although the results disclosed no significant differences in lesion size or path length between the two groups, the stereotaxically guided biopsies required 75% fewer needle manipulations to hit the intended target. Consequently, the stereotaxically guided biopsies required 40% less time and 80% fewer localization scans to find the biopsy needle than did the hand-guided biopsies

  2. Hypoxia marker labeling in tumor biopsies: quantification of labeling variation and criteria for biopsy sectioning

    International Nuclear Information System (INIS)

    Thrall, Donald E.; Rosner, Gary L.; Azuma, Chieko; McEntee, Margaret C.; Raleigh, James A.

    1997-01-01

    Background and purpose: The error associated with using biopsy-based methods for assessing parameters reflective of the tumor microenvironment depends on the variability in distribution of the parameter throughout the tumor and the biopsy sample. Some attention has been given to intratumoral distribution of parameters, but little attention has been given to their intrabiopsy distribution. We evaluated the intrabiopsy distribution of CCI-103F, a 2-nitroimidazole hypoxia marker. Materials and methods: The hypoxia marker CCI-103F was studied in dogs bearing spontaneous solid tumors. Two biopsies were taken from each of seven tumors, for a total of 14 biopsies. Biopsies were serially sectioned and four to six contiguous slides from each 100-150 μm of the biopsy were used to formulate the best estimate of CCI-103F labeled area throughout the biopsy sample. One, two or four slides were then randomly selected from each biopsy and the labeled area, based on this limited sample, was compared to the estimate obtained from counting all available slides. Random sampling of slides was repeated 1000 times for each biopsy sample. Results: CCI-103F labeling variance throughout the biopsy decreased as the estimated overall labeled area in the biopsy decreased. The error associated with estimating the overall labeled area in a biopsy from a randomly selected subset of slides decreased as the number of slides increased, and as the overall labeled area in the biopsy decreased. No minimally labeled biopsy was classified as unlabeled based on limited sampling. Conclusion: With regard to CCI-103F labeling, quantification of the labeled area in four randomly selected slides from a biopsy can provide, in most biopsies, an estimate of the labeled area in the biopsy within an absolute range of ±0.05

  3. Session summaries

    International Nuclear Information System (INIS)

    Sudo, Y.

    2002-01-01

    In the summary session, possible international activities in the field of basic studies on high-temperature engineering were discussed within the framework of the OECD/NEA Nuclear Science Committee (NSC). It was recommended to include topics relevant to fission-product behaviour and safety issues of HTGR in next meeting, in addition to the topics discussed in this meeting. The chairperson of the last session summarised the recommendations to be presented to the NSC into the following five topics as possible international activities: - Basic studies on behaviour of irradiated graphite/carbon and ceramic materials including their composites under both operation and storage conditions. - Development of in-core material characterisation and instrumentation methods. - Improvement in material properties through high-temperature irradiation. - Basic studies on HTGR fuel fabrication and performance including fission-product release. - Basic studies on safety issues of HTGR. It was also recommended that a further information exchange meeting focused on the organisation of the interactive collaboration activity with regard to the above topics be planned in 2003, tentatively in Oarai, Japan. (author)

  4. Session Introduction

    Science.gov (United States)

    Eliane Lessner, Co-Chair:

    2009-03-01

    A panel discussion session providing a worldwide assessment of the status and experiences of women in physics, paying attention to the different cultures and environments they work in and to how the age of the physicist affects their perspective. We will hear about women physicists in Korea in particular and Asia in general, in Egypt in particular and Africa in general, and in the Caribbean. Six invited speakers will present analyses of the progress being made in promoting women in physics from their personal experiences and as assessed from their participation in the Third International Conference on Women In Physics (ICWIP2008) convened in Seoul, Korea in October 2008. From Albania to Zimbabwe, with representation of all the continents, ICWIP2008 congregated 283 women and men physicists from 57 countries to share the participants' scientific accomplishments and evaluate international progress in improving the status of women in physics. This three-hour session is organized jointly by the Committee on the Status of Women in Physics of the APS (CSWP) and the Forum on International Physics of the APS (FIP). Audience participation in the panel discussion will be strongly encouraged.

  5. Repeat Customer Success in Extension

    Science.gov (United States)

    Bess, Melissa M.; Traub, Sarah M.

    2013-01-01

    Four multi-session research-based programs were offered by two Extension specialist in one rural Missouri county. Eleven participants who came to multiple Extension programs could be called "repeat customers." Based on the total number of participants for all four programs, 25% could be deemed as repeat customers. Repeat customers had…

  6. Immediate Effects of a Single Session of Motor Skill Training on the Lumbar Movement Pattern During a Functional Activity in People With Low Back Pain: A Repeated-Measures Study.

    Science.gov (United States)

    Marich, Andrej V; Lanier, Vanessa M; Salsich, Gretchen B; Lang, Catherine E; Van Dillen, Linda R

    2018-04-06

    People with low back pain (LBP) may display an altered lumbar movement pattern of early lumbar motion compared to people with healthy backs. Modifying this movement pattern during a clinical test decreases pain. It is unknown whether similar effects would be seen during a functional activity. The objective of this study is was to examine the lumbar movement patterns before and after motor skill training, effects on pain, and characteristics that influenced the ability to modify movement patterns. The design consisted of a repeated-measures study examining early-phase lumbar excursion in people with LBP during a functional activity test. Twenty-six people with chronic LBP received motor skill training, and 16 people with healthy backs were recruited as a reference standard. Twenty minutes of motor skill training to decrease early-phase lumbar excursion during the performance of a functional activity were used as a treatment intervention. Early-phase lumbar excursion was measured before and after training. Participants verbally reported increased pain, decreased pain, or no change in pain during performance of the functional activity test movement in relation to their baseline pain. The characteristics of people with LBP that influenced the ability to decrease early-phase lumbar excursion were examined. People with LBP displayed greater early-phase lumbar excursion before training than people with healthy backs (LBP: mean = 11.2°, 95% CI = 9.3°-13.1°; healthy backs: mean = 7.1°, 95% CI = 5.8°-8.4°). Following training, the LBP group showed a decrease in the amount of early-phase lumbar excursion (mean change = 4.1°, 95% CI = 2.4°-5.8°); 91% of people with LBP reported that their pain decreased from baseline following training. The longer the duration of LBP (β = - 0.22) and the more early-phase lumbar excursion before training (β = - 0.82), the greater the change in early-phase lumbar excursion following training. The long

  7. MR-guided biopsies

    International Nuclear Information System (INIS)

    Gehl, H.B.; Frahm, C.

    1998-01-01

    Biopsies were the first 'intervention' under MR guidance. After initial difficulties concerning ferromagnetic biopsy instruments and the design of MR scanners, the latest technological improvements rendered MR guidance for biopsies more feasible. In this article we illustrate present-day clinical experience in the field of abdominal, breast and bone biopsy. Important aspects regarding the different designs of 'interventional' MR scanners and the visualization of instruments for biopsy are discussed. (orig.) [de

  8. The percentage of prostate-specific antigen (PSA) isoform [-2]proPSA and the Prostate Health Index improve the diagnostic accuracy for clinically relevant prostate cancer at initial and repeat biopsy compared with total PSA and percentage free PSA in men aged ≤65 years.

    Science.gov (United States)

    Boegemann, Martin; Stephan, Carsten; Cammann, Henning; Vincendeau, Sébastien; Houlgatte, Alain; Jung, Klaus; Blanchet, Jean-Sebastien; Semjonow, Axel

    2016-01-01

    To prospectively test the diagnostic accuracy of the percentage of prostate specific antigen (PSA) isoform [-2]proPSA (%p2PSA) and the Prostate Health Index (PHI), and to determine their role for discrimination between significant and insignificant prostate cancer at initial and repeat prostate biopsy in men aged ≤65 years. The diagnostic performance of %p2PSA and PHI were evaluated in a multicentre study. In all, 769 men aged ≤65 years scheduled for initial or repeat prostate biopsy were recruited in four sites based on a total PSA (t-PSA) level of 1.6-8.0 ng/mL World Health Organization (WHO) calibrated (2-10 ng/mL Hybritech-calibrated). Serum samples were measured for the concentration of t-PSA, free PSA (f-PSA) and p2PSA with Beckman Coulter immunoassays on Access-2 or DxI800 instruments. PHI was calculated as (p2PSA/f-PSA × √t-PSA). Uni- and multivariable logistic regression models and an artificial neural network (ANN) were complemented by decision curve analysis (DCA). In univariate analysis %p2PSA and PHI were the best predictors of prostate cancer detection in all patients (area under the curve [AUC] 0.72 and 0.73, respectively), at initial (AUC 0.67 and 0.69) and repeat biopsy (AUC 0.74 and 0.74). t-PSA and %f-PSA performed less accurately for all patients (AUC 0.54 and 0.62). For detection of significant prostate cancer (based on Prostate Cancer Research International Active Surveillance [PRIAS] criteria) the %p2PSA and PHI equally demonstrated best performance (AUC 0.70 and 0.73) compared with t-PSA and %f-PSA (AUC 0.54 and 0.59). In multivariate analysis PHI we added to a base model of age, prostate volume, digital rectal examination, t-PSA and %f-PSA. PHI was strongest in predicting prostate cancer in all patients, at initial and repeat biopsy and for significant prostate cancer (AUC 0.73, 0.68, 0.78 and 0.72, respectively). In DCA for all patients the ANN showed the broadest threshold probability and best net benefit. PHI as single parameter

  9. The influence of the leader on the movement of the horse in walking during repeated hippotherapy sessions [Vliv vodiče na pohyb koně v kroku v opakovaných lekcích hipoterapie

    Directory of Open Access Journals (Sweden)

    Tereza Dvořáková

    2009-09-01

    Full Text Available BACKGROUND: The movement of a walking horse is utilized as a tool for a therapeutic effect in hippotherapy. The movement impulses of the horse's back are influenced by the movement action of its limbs, morphology, speed of walk, etc. OBJECTIVE: The aim of the study was to evaluate the influence of the leader on a horse's movement while walking during repeated hippotherapy treatment sessions. METHODS: Three dimensional (3D videography was used for the assessment of the movements of a horse (selected points on the limbs and back and a human being (reaction to the horse's movement. The study was done with the repeated measurements (n = 6 of the movement of horses (n = 2 and riders (n = 12 during five weeks of hippotherapy intervention (9 sessions in total by the different leaders (n = 6 of the horses. RESULTS: There are differences in the range of movement of selected points on the limbs and back of the horse while leading it as done by different leaders (p < 0.05, p < 0.01. The changes in the kinematics of the horse's limbs are transmitted to the horseback movements of horse H1 only within a limited range. The range of the differences on the limbs and back for horse H2 is similar. The movement responses of healthy riders show differences in the lower part of the spine (p < 0.05; in the upper part of the spine the differences are minimal. The horse leader is one of the key factors for adhering to the desired medical effect, which is established on the basis of the intervention of physiotherapy throughout hippotherapy. CONCLUSIONS: As there are a number of factors which could have a negative effect on the movement of the horse (weather, disturbing influences of the environment, low quality surface, the activities of the horse leader in keeping the relevant direction and speed of the horse's movement are decisive factors. This study emphasises the significance of the role of the horse leader in therapy and puts stress on his/her level of

  10. Biopsy-proven childhood glomerulonephritis in Johor.

    Science.gov (United States)

    Khoo, J J; Pee, S; Thevarajah, B; Yap, Y C; Chin, C K

    2004-06-01

    There has been no published study of biopsy-proven childhood glomerulonephritis in Malaysia. To determine the pattern of childhood glomerulonephritis in Johor, Malaysia from a histopathological perspective and the various indications used for renal biopsy in children. Retrospective study was done of all renal biopsies from children under 16 years of age, received in Sultanah Aminah Hospital, Johor between 1994 and 2001. The histopathological findings were reviewed to determine the pattern of biopsy-proven glomerulonephritis. The indications for biopsy, mode of therapy given after biopsy and the clinical outcome were studied. 122 adequate biopsies were received, 9 children had repeat biopsies. Of the 113 biopsies, minimal change disease formed the most common histopathological diagnosis (40.7%) while lupus nephritis formed the most common secondary glomerulonephritis (23.0%). The main indications for biopsy were nephrotic syndrome (50.8%), lupus nephritis (25.4%) and renal impairment (13.1%). The mode of therapy was changed in 59.8% of the children. Of 106 patients followed-up, 84 children were found to have normal renal function in remission or on treatment. 4 patients developed chronic renal impairment and 16 reached end stage renal disease. Five of the 16 children with end stage disease had since died while 11 were on renal replacement therapy. Another 2 patients died of other complications. The pattern of childhood GN in our study tended to reflect the more severe renal parenchymal diseases in children and those requiring more aggressive treatment. This was because of our criteria of selection (indication) for renal biopsy. Renal biopsy where performed appropriately in selected children may not only be a useful investigative tool for histological diagnosis and prognosis but may help clinicians plan the optimal therapy for these children.

  11. Special session on environment and energy, and repeated emphasis from early-'80s onwards, hybrid-drive targets for penetrating beams, that encompasses ultra high intensity lasers and/or particle beams

    International Nuclear Information System (INIS)

    Mark, J.W.

    1994-01-01

    In this special session, we discuss global climate change concerns, as well as cleanup of wastes and/or toxic materials, their relations to energy and other technologies. We especially bring together scientists to discuss available and/or developable technologies of amelioration or cleanup, for consideration of unusual uses of Lasers, Particle Beams and other plasma Phenomena. copyright American Institute of Physics 1994

  12. Salivary gland biopsy

    Science.gov (United States)

    ... also be performed to diagnose diseases such as Sjogren syndrome . How to Prepare for the Test There is ... few days after the biopsy. The biopsy for Sjogren syndrome requires an injection of the anesthetic in the ...

  13. Outcomes of ultrasound guided renal mass biopsies.

    Science.gov (United States)

    Sutherland, Edward L; Choromanska, Agnieszka; Al-Katib, Sayf; Coffey, Mary

    2018-06-01

    The purpose of this study was to evaluate the rate of nondiagnostic ultrasound-guided renal mass biopsies (RMBs) at our institution and to determine what patient, procedural, and focal renal mass (FRM) factors were associated with nondiagnostic ultrasound-guided RMBs. Eighty-two ultrasound-guided renal mass biopsies performed between January 2014 and October 2016 were included in our study. Biopsy outcomes (diagnostic vs. nondiagnostic) and patient, procedural, and FRM characteristics were retrospectively reviewed and recorded. Univariate statistical analyses were performed to identify biopsy characteristics that were indicative of nondiagnostic biopsy. Ultrasound-guided RMBs were diagnostic in 70 out of 82 cases (85%) and non-diagnostic in 12 cases (15%). Among the diagnostic biopsies, 54 (77%) were malignant cases, 94% of which were renal cell carcinoma (RCC). Of the 12 nondiagnostic cases, the final diagnosis was RCC in 4 cases and angiomyolipoma in one case; seven of the nondiagnostic cases were lost to follow-up. A weak association (p = 0.04) was found between the number of needle passes and the biopsy outcome. None of the remaining collected RMB characteristics showed a significant correlation with a diagnostic or nondiagnostic RMB. Six patients (7%) experienced complications. Ultrasound-guided renal mass biopsy is a safe and effective method for the diagnosis of renal masses with a low rate of nondiagnostic outcomes. A nondiagnostic biopsy should not be treated as a surrogate for a diagnosis since a significant number of patients with nondiagnostic biopsies have subsequently been shown to have renal malignancies. Repeat biopsy should be considered in such cases.

  14. Abdominal wall fat pad biopsy

    Science.gov (United States)

    Amyloidosis - abdominal wall fat pad biopsy; Abdominal wall biopsy; Biopsy - abdominal wall fat pad ... is the most common method of taking an abdominal wall fat pad biopsy . The health care provider cleans the ...

  15. In-Bore MR-Guided Biopsy Systems and Utility of PI-RADS

    NARCIS (Netherlands)

    Futterer, J.J.; Moche, M.; Busse, H.; Yakar, D.

    2016-01-01

    A diagnostic dilemma exists in cases wherein a patient with clinical suspicion for prostate cancer has a negative transrectal ultrasound-guided biopsy session. Although transrectal ultrasound-guided biopsy is the standard of care, a paradigm shift is being observed. In biopsy-naive patients and

  16. La biopsie prostatique

    OpenAIRE

    DJEDOUI, MERIEM

    2013-01-01

    La preuve d'un cancer de la prostate est apportée par la biopsie prostatique. Malheureusement, une biopsie négative, bien que rassurante, ne suffit pas à exclure un noyau cancéreux à côté duquel l'aiguille est passée. L'urologue peut être amené à proposer une nouvelle biopsie, en augmentant, s'il le faut, le nombre de prélèvements de tissu prostatique. Ayant connu Le but d'une biopsie prostatique, le patient pourrait maintenant décider d'entrer dans d'autres alternatives qui...

  17. In-Bore MR-Guided Biopsy Systems and Utility of PI-RADS.

    Science.gov (United States)

    Fütterer, Jurgen J; Moche, Michael; Busse, Harald; Yakar, Derya

    2016-06-01

    A diagnostic dilemma exists in cases wherein a patient with clinical suspicion for prostate cancer has a negative transrectal ultrasound-guided biopsy session. Although transrectal ultrasound-guided biopsy is the standard of care, a paradigm shift is being observed. In biopsy-naive patients and patients with at least 1 negative biopsy session, multiparametric magnetic resonance imaging (MRI) is being utilized for tumor detection and subsequent targeting. Several commercial devices are now available for targeted prostate biopsy ranging from transrectal ultrasound-MR fusion biopsy to in bore MR-guided biopsy. In this review, we will give an update on the current status of in-bore MRI-guided biopsy systems and discuss value of prostate imaging-reporting and data system (PIRADS).

  18. Biopsy - Multiple Languages

    Science.gov (United States)

    ... Biopsy - العربية (Arabic) Bilingual PDF Health Information Translations Breast Biopsy - العربية (Arabic) Bilingual PDF Health Information Translations Colposcopy - العربية (Arabic) Bilingual PDF ...

  19. Improved transvenous liver biopsy needle

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Matzen, P; Christoffersen, P

    1979-01-01

    A modified type of the standard transvenous cholangiography biopsy needle is described. The modified tranvenous liver biopsy needle caused only minimal artefactual changes of the liver biopsy specimens. The new type of biopsy needle is a modified Menghini needle. The conventional Menghini needle...... should be avoided for transvenous catheter biopsies because of risk of leaving catheter fragments in the liver....

  20. Changes in the biogenic amine content of the prefrontal cortex, amygdala, dorsal hippocampus, and nucleus accumbens of rats submitted to single and repeated sessions of the elevated plus-maze test

    Directory of Open Access Journals (Sweden)

    Carvalho M.C.

    2005-01-01

    Full Text Available It has been demonstrated that exposure to a variety of stressful experiences enhances fearful reactions when behavior is tested in current animal models of anxiety. Until now, no study has examined the neurochemical changes during the test and retest sessions of rats submitted to the elevated plus maze (EPM. The present study uses a new approach (HPLC by looking at the changes in dopamine and serotonin levels in the prefrontal cortex, amygdala, dorsal hippocampus, and nucleus accumbens in animals upon single or double exposure to the EPM (one-trial tolerance. The study involved two experiments: i saline or midazolam (0.5 mg/kg before the first trial, and ii saline or midazolam before the second trial. For the biochemical analysis a control group injected with saline and not tested in the EPM was included. Stressful stimuli in the EPM were able to elicit one-trial tolerance to midazolam on re-exposure (61.01%. Significant decreases in serotonin contents occurred in the prefrontal cortex (38.74%, amygdala (78.96%, dorsal hippocampus (70.33%, and nucleus accumbens (73.58% of the animals tested in the EPM (P < 0.05 in all cases in relation to controls not exposed to the EPM. A significant decrease in dopamine content was also observed in the amygdala (54.74%, P < 0.05. These changes were maintained across trials. There was no change in the turnover rates of these monoamines. We suggest that exposure to the EPM causes reduced monoaminergic neurotransmission activity in limbic structures, which appears to underlie the "one-trial tolerance" phenomenon.

  1. No need for biopsies

    DEFF Research Database (Denmark)

    Gjødsbøl, Kristine; Skindersoe, Mette E; Christensen, Jens Jørgen

    2011-01-01

    The aim of the study was to compare three sampling techniques used in routine diagnostics to identify the microbiota in chronic venous leg ulcers. A total of 46 patients with persisting venous leg ulcers were included in the study. At inclusion, swab, biopsy and filter paper pad samples were...... collected. After 4 weeks, additional biopsy and filter paper pad samples were collected. Bacteria were isolated and identified at species level by standard methods. The most common bacterial species detected was Staphylococcus aureus found in 89% of the ulcers. No methicillin-resistant S. aureus isolates...... species present in chronic wounds, thus avoiding complications during and after biopsy sampling....

  2. Breast biopsy -- stereotactic

    Science.gov (United States)

    ... org/-/media/ACR/Files/Practice-Parameters/stereo-breast.pdf . Updated 2016. Accessed March 14, 2017. Parker C, Umphrey H, Bland K. The role of stereotactic breast biopsy in the management of breast disease. In: Cameron ...

  3. Breast biopsy -- ultrasound

    Science.gov (United States)

    ... org/-/media/ACR/Files/Practice-Parameters/us-guidedbreast.pdf . Updated 2016. Accessed March 14, 2017. Torrente J, Brem RF. Minimally invasive image-guided breast biopsy and ablation. In: Mauro MA, Murphy KPJ, Thomson ...

  4. Pleural needle biopsy

    Science.gov (United States)

    ... own. Sometimes, a chest tube is needed to drain the air and expand the lung. There is also a chance of excessive blood loss. Considerations If a closed pleural biopsy is not enough to make a diagnosis, ...

  5. Colposcopy - directed biopsy

    Science.gov (United States)

    ... squamous cells - colposcopy; Pap smear - colposcopy; HPV - colposcopy; Human papilloma virus - colposcopy; Cervix - colposcopy; Colposcopy ... also called cervical dysplasia) Cervical warts (infection with human papilloma virus , or HPV) If the biopsy does not ...

  6. Corpus vitreum, retina og chorioidea biopsi

    DEFF Research Database (Denmark)

    Scherfig, Erik Christian Høegh

    2002-01-01

    oftalmology, biopsy, choroid, corpus vitreum, retina, malignant melanoma, biopsy technic, retinoblastoma......oftalmology, biopsy, choroid, corpus vitreum, retina, malignant melanoma, biopsy technic, retinoblastoma...

  7. Sonographically guided core biopsy of the breast: comparison of 14-gauge automated gun and 11-gauge directional vacuum-assisted biopsy methods

    International Nuclear Information System (INIS)

    Cho, Nariya; Moon, Woo Kyung; Cha, Joo Hee

    2005-01-01

    To compare the outcomes of 14-gauge automated biopsy and 11-gauge vacuum-assisted biopsy for the sonographically guided core biopsies of breast lesions. We retrospectively reviewed all sonographically guided core biopsies performed from January 2002 to February 2004. The sonographically guided core biopsies were performed with using a 14-gauge automated gun on 562 breast lesions or with using an 11-gauge vacuum-assisted device on 417 lesions. The histologic findings were compared with the surgical, imaging and follow-up findings. The histologic underestimation rate, the repeat biopsy rate and the false negative rates were compared between the two groups. A repeat biopsy was performed on 49 benign lesions because of the core biopsy results of the high-risk lesions (n=24), the imaging-histologic discordance (n=5), and the imaging findings showing disease progression (n=20). The total underestimation rates, according to the biopsy device, were 55% (12/22) for the 14-gauge automated gun biopsies and 36% (8/22) for the 11-gauge vacuum-assisted device (ρ = 0.226). The atypical ductal hyperplasia (ADH) underestimation (i.e., atypical ductal hyperplasia at core biopsy and carcinoma at surgery) was 58% (7/12) for the 14-gauge automated gun biopsies and 20% (1/5) for the 11-gauge vacuum-assisted biopsies. The ductal carcinoma in situ (DCIS) underestimation rate (i.e., ductal carcinoma in situ upon core biopsy and invasive carcinoma found at surgery) was 50% (5/10) for the 14-gauge automated gun biopsies and 41% (7/17) for the 11-gauge vacuum-assisted biopsies. The repeat biopsy rates were 6% (33/562) for the 14-gauge automated gun biopsies and 3.5% (16/417) for the 11-gauge vacuum-assisted biopsies. Only 5 (0.5%) of the 979 core biopsies were believed to have missed the malignant lesions. The false-negative rate was 3% (4 of 128 cancers) for the 14-gauge automated gun biopsies and 1% (1 of 69 cancers) for the 11-gauge vacuum-assisted biopsies. The outcomes of the

  8. Biopsy in Musculoskeletal Tumors

    Directory of Open Access Journals (Sweden)

    Mohammad Gharehdaghi

    2014-09-01

    Full Text Available Diagnosis of bone tumors is based on careful evaluation of clinical, imaging and a pathologic findings. So the biopsy of bone and soft tissue sarcomas is the final step in evaluation and a fundamental step in the diagnosis of the lesion. It should not be performed as a shortcut to diagnosis (1. The biopsy should be performed in order to confirm the diagnosis and differentiate among few diagnoses after careful staged studies. Real and artificial changes in imaging studies will be superimposed after performing biopsy, which may alter the interpretation if done after biopsy is taken (1. The correct management of a sarcoma depends on the accurate diagnosis. Inadequate, inapprppriate, or inaccurate non-representative biopsy leads to poorer outcome in terms of survivorship and limb salvage. An incorrect, unplanned incision and biopsy may unnecessarily contaminate uninvolved compartments which may convert a salvageable limb to amputation. Anatomic approach along with the proper biopsy techniques may lead to success or catastrophe. It is clear that in patients with inappropriate biopsy, the chance of the need to change the treatment to more radical than would originally be expected is significantly higher. Also it is more probable to need to  convert curative to palliative treatment and to require adjuvant radiotherapy in patients with inappropriate biopsies. Patients with sarcoma are best served by early referral to a specialized center where staged investigations and biopsy can be performed with minimal morbidity (3. Open biopsy is still considered the gold standard; however, recent studies suggest comparable results with percutaneous core needle biopsy. Our study on 103 consecutive CNB and open biopsy showed comparable results as well. Surgeons need to answer to two questions prior to performing a biopsy: 1-          Where is the best part of the lesion to be biopsied? 2-          What is the safest route without contaminating

  9. Deployment Repeatability

    Science.gov (United States)

    2016-04-01

    evaluating the deployment repeatability builds upon the testing or analysis of deployment kinematics (Chapter 6) and adds repetition. Introduction...material yield or failure during a test. For the purposes of this chapter, zero shift will refer to permanent changes in the structure, while reversible ...the content of other chapters in this book: Gravity Compensation (Chapter 4) and Deployment Kinematics and Dynamics (Chapter 6). Repeating the

  10. Percutaneous CT-guided needle biopsies of musculoskeletal tumors: a 5-year analysis of non-diagnostic biopsies

    International Nuclear Information System (INIS)

    Chang, Connie Y.; Huang, Ambrose J.; Bredella, Miriam A.; Torriani, Martin; Rosenthal, Daniel I.; Halpern, Elkan F.; Springfield, Dempsey S.

    2015-01-01

    To study non-diagnostic CT-guided musculoskeletal biopsies and take steps to minimize them. Specifically we asked: (1) What malignant diagnoses have a higher non-diagnostic rate? (2) What factors of a non-diagnostic biopsy may warrant more aggressive pursuit? (3) Do intra-procedural frozen pathology (FP) or point-of-care (POC) cytology reduce the non-diagnostic biopsy rate ?This study was IRB-approved and HIPAA-compliant. We retrospectively reviewed 963 consecutive CT-guided musculoskeletal biopsies. We categorized pathology results as malignant, benign, or non-diagnostic and recorded use of FP or POC cytology. Initial biopsy indication, final diagnosis, method of obtaining the final diagnosis of non-diagnostic biopsies, age of the patient, and years of biopsy attending experience were recorded. Groups were compared using Pearson's χ 2 test or Fisher's exact test. In all, 140 of 963 (15 %) biopsies were non-diagnostic. Lymphoma resulted in more non-diagnostic biopsies (P < 0.0001). While 67% of non-diagnostic biopsies yielded benign diagnoses, 33% yielded malignant diagnoses. Patients whose percutaneous biopsy was indicated due to the clinical context without malignancy history almost always generated benign results (96 %). Whereas 56% of biopsies whose indication was an imaging finding of a treatable lesion were malignant, 20% of biopsies whose indication was a history of malignancy were malignant. There was no statistically significant difference in the nondiagnostic biopsy rates of pediatric versus adult patients (P = 0.8) and of biopsy attendings with fewer versus more years of experience (P = 0.5). The non-diagnostic rates of biopsies with FP (8 %), POC cytology (25 %), or neither (24 %) were significantly different (P < 0.0001). Lymphoma is the malignant diagnosis most likely to result in a non-diagnostic biopsy. If the clinical and radiologic suspicion for malignancy is high, repeat biopsy is warranted. If the clinical context suggests a benign

  11. Percutaneous CT-guided needle biopsies of musculoskeletal tumors: a 5-year analysis of non-diagnostic biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Connie Y.; Huang, Ambrose J.; Bredella, Miriam A.; Torriani, Martin; Rosenthal, Daniel I. [Massachusetts General Hospital, Division of Musculoskeletal Imaging and Intervention, Department of Radiology, Boston, MA (United States); Halpern, Elkan F. [Massachusetts General Hospital, Institute for Technology Assessment, Department of Radiology, Boston, MA (United States); Springfield, Dempsey S. [Massachusetts General Hospital, Department of Orthopedics, Boston, MA (United States)

    2015-12-15

    To study non-diagnostic CT-guided musculoskeletal biopsies and take steps to minimize them. Specifically we asked: (1) What malignant diagnoses have a higher non-diagnostic rate? (2) What factors of a non-diagnostic biopsy may warrant more aggressive pursuit? (3) Do intra-procedural frozen pathology (FP) or point-of-care (POC) cytology reduce the non-diagnostic biopsy rate ?This study was IRB-approved and HIPAA-compliant. We retrospectively reviewed 963 consecutive CT-guided musculoskeletal biopsies. We categorized pathology results as malignant, benign, or non-diagnostic and recorded use of FP or POC cytology. Initial biopsy indication, final diagnosis, method of obtaining the final diagnosis of non-diagnostic biopsies, age of the patient, and years of biopsy attending experience were recorded. Groups were compared using Pearson's χ{sup 2} test or Fisher's exact test. In all, 140 of 963 (15 %) biopsies were non-diagnostic. Lymphoma resulted in more non-diagnostic biopsies (P < 0.0001). While 67% of non-diagnostic biopsies yielded benign diagnoses, 33% yielded malignant diagnoses. Patients whose percutaneous biopsy was indicated due to the clinical context without malignancy history almost always generated benign results (96 %). Whereas 56% of biopsies whose indication was an imaging finding of a treatable lesion were malignant, 20% of biopsies whose indication was a history of malignancy were malignant. There was no statistically significant difference in the nondiagnostic biopsy rates of pediatric versus adult patients (P = 0.8) and of biopsy attendings with fewer versus more years of experience (P = 0.5). The non-diagnostic rates of biopsies with FP (8 %), POC cytology (25 %), or neither (24 %) were significantly different (P < 0.0001). Lymphoma is the malignant diagnosis most likely to result in a non-diagnostic biopsy. If the clinical and radiologic suspicion for malignancy is high, repeat biopsy is warranted. If the clinical context suggests a

  12. Post-Session Authentication

    DEFF Research Database (Denmark)

    Ahmed, Naveed; Jensen, Christian D.

    2012-01-01

    Entity authentication provides confidence in the claimed identity of a peer entity, but the manner in which this goal is achieved results in different types of authentication. An important factor in this regard is the order between authentication and the execution of the associated session....... In this paper, we consider the case of post-session authentication, where parties authenticate each other at the end of their interactive session. This use of authentication is different from session-less authentication (e.g., in RFID) and pre-session authentication (e.g., for access control.) Post......-session authentication, although a new term, is not a new concept; it is the basis of at least a few practical schemes. We, for the first time, systematically study it and present the underlying authentication model. Further, we show that an important class of problems is solvable using post-session authentication...

  13. False-negative results of breast core needle biopsies – retrospective analysis of 988 biopsies

    International Nuclear Information System (INIS)

    Boba, Marek; Kołtun, Urszula; Bobek-Billewicz, Barbara; Chmielik, Ewa; Eksner, Bartosz; Olejnik, Tomasz

    2011-01-01

    Breast cancer is the most common malignant neoplasm and the most common cause of death among women. The core needle biopsy is becoming a universal practice in diagnosing breast lesions suspected of malignancy. Unfortunately, breast core needle biopsies also bear the risk of having false-negative results. 988 core needle breast biopsies were performed at the Maria Skłodowska-Curie Memorial Cancer Center and Institute of Oncology, Gliwice Branch, between 01 March 2006 and 29 February 2008. Malignant lesions were diagnosed in 426/988 (43.12%) cases, atypical hyperplasia in 69/988 (6.98%), and benign lesions in 493/988 (49.90%) cases. Twenty-two out of 988 biopsies (2.23%) were found to be false negative. Histopathological assessment of tissue specimens was repeated in these cases. In 14/22 (64%) cases, the previous diagnosis of a benign lesion was changed. In 8/22 (36%) cases, the diagnosis of a benign lesion was confirmed. False-negative rate was calculated at 2.2%. The rate of false-negative diagnoses resulting from a radiological mistake was estimated at 36%. The rate of false-negative diagnoses, resulting from histopathological assessment, was 64%. False-negative results caused by a radiological error comprised 1.5% of all histopathologically diagnosed cancers and atypias (sensitivity of 98.5%). There were no false-positive results in our material - the specificity of the method was 100%. Histopathological interpretation is a substantial cause of false-negative results of breast core needle biopsy. Thus, in case of a radiological-histopathological divergence, histopathological analysis of biopsy specimens should be repeated. The main radiological causes of false-negative results of breast core needle biopsy are as follows: sampling from an inappropriate site and histopathological non-homogeneity of cancer infiltration

  14. False-negative results of breast core needle biopsies - retrospective analysis of 988 biopsies

    International Nuclear Information System (INIS)

    Boba, M.; Koltun, U.; Bobek-Billewicz, B.; Eksner, B.; Olejnik, T.; Chmielik, E.

    2011-01-01

    Background: Breast cancer is the most common malignant neoplasm and the most common cause of death among women. The core needle biopsy is becoming a universal practice in diagnosing breast lesions suspected of malignancy. Unfortunately, breast core needle biopsies also bear the risk of having false-negative results. Material/Methods: 988 core needle breast biopsies were performed at the Maria Sklodowska-Curie Memorial Cancer Center and Institute of Oncology, Gliwice Branch, between 01 March 2006 and 29 February 2008. Malignant lesions were diagnosed in 426/988 (43.12%) cases, atypical hyperplasia in 69/988 (6.98%), and benign lesions in 493/988 (49.90%) cases. Results: Twenty-two out of 988 biopsies (2.23%) were found to be false negative. Histopathological assessment of tissue specimens was repeated in these cases. In 14/22 (64%) cases, the previous diagnosis of a benign lesion was changed. In 8/22 (36%) cases, the diagnosis of a benign lesion was confirmed. False-negative rate was calculated at 2.2%. The rate of false-negative diagnoses resulting from a radiological mistake was estimated at 36%. The rate of false-negative diagnoses, resulting from histopathological assessment, was 64%. False-negative results caused by a radiological error comprised 1.5% of all histopathologically diagnosed cancers and atypias (sensitivity of 98.5%). There were no false-positive results in our material - the specificity of the method was 100%. Conclusions: Histopathological interpretation is a substantial cause of false-negative results of breast core needle biopsy. Thus, in case of a radiological-histopathological divergence, histopathological analysis of biopsy specimens should be repeated. The main radiological causes of false-negative results of breast core needle biopsy are as follows: sampling from an inappropriate site and histopathological non-homogeneity of cancer infiltration. (authors)

  15. Post-Session Authentication

    OpenAIRE

    Ahmed , Naveed; Jensen , Christian ,

    2012-01-01

    Part 1: Full Papers; International audience; Entity authentication provides confidence in the claimed identity of a peer entity, but the manner in which this goal is achieved results in different types of authentication. An important factor in this regard is the order between authentication and the execution of the associated session. In this paper, we consider the case of post-session authentication, where parties authenticate each other at the end of their interactive session. This use of a...

  16. Lung needle biopsy

    Science.gov (United States)

    ... if you have certain lung diseases such as emphysema. Usually, a collapsed lung after a biopsy does not need treatment. But ... any type Bullae (enlarged alveoli that occur with emphysema) Cor pulmonale (condition ... of the lung High blood pressure in the lung arteries Severe ...

  17. Closed Pericardial Biopsy

    African Journals Online (AJOL)

    1974-09-28

    Sep 28, 1974 ... The instrument used is a hook biopsy needle (Fig. I). manufactured by Becton, Dickinson and Co., Rutherford,. New Jersey, USA. The instrument' and technique' will be reviewed. The instrument consists of an ll-gauge needle with a sharp cutting edge into which fits, interchangeably, a 13-gauge needle or a ...

  18. CONE BIOPSY IN PREGNANCY*

    African Journals Online (AJOL)

    1 Mei 1971. S.-A. TYDSKRIF VIR OBSTETRIE EN GINEKOLOGIE. CONE BIOPSY ... of the abnormal cervix in pregnancy is also no longer in question following the .... the concept of cancer prophylaxis to the majority of women, many of whom ...

  19. Repeating Marx

    DEFF Research Database (Denmark)

    Fuchs, Christian; Monticelli, Lara

    2018-01-01

    This introduction sets out the context of the special issue “Karl Marx @ 200: Debating Capitalism & Perspectives for the Future of Radical Theory”, which was published on the occasion of Marx’s bicentenary on 5 May 2018. First, we give a brief overview of contemporary capitalism’s development...... and its crises. Second, we argue that it is important to repeat Marx today. Third, we reflect on lessons learned from 200 years of struggles for alternatives to capitalism. Fourth, we give an overview of the contributions in this special issue. Taken together, the contributions in this special issue show...... that Marx’s theory and politics remain key inspirations for understanding exploitation and domination in 21st-century society and for struggles that aim to overcome these phenomena and establishing a just and fair society. We need to repeat Marx today....

  20. The Public Poster Session

    Science.gov (United States)

    Levine-Rasky, Cynthia

    2009-01-01

    This note describes the use of a student poster session as an innovative approach to student learning. The local context for the assignment is provided, followed by a description of the course for which the poster was prepared, details about the assignment including its evaluation, and practical considerations for planning a poster session. The…

  1. Deployment Repeatability

    Science.gov (United States)

    2016-08-31

    large cohort of trials to spot unusual cases. However, deployment repeatability is inherently a nonlinear phenomenon, which makes modeling difficult...and GEMS tip position were both tracked during ground testing by a laser target tracking system. Earlier SAILMAST testing in 2005 [8] used...recalls the strategy used by SRTM, where a constellation of lights was installed at the tip of the boom and a modified star tracker was used to track tip

  2. Multiparty Asynchronous Session Types

    DEFF Research Database (Denmark)

    Honda, Kohei; Yoshida, Nobuko; Carbone, Marco

    2016-01-01

    . This work extends the foregoing theories of binary session types to multiparty, asynchronous sessions, which often arise in practical communication-centered applications. Presented as a typed calculus for mobile processes, the theory introduces a new notion of types in which interactions involving multiple......Communication is a central elements in software development. As a potential typed foundation for structured communication-centered programming, session types have been studied over the past decade for a wide range of process calculi and programming languages, focusing on binary (two-party) sessions...... peers are directly abstracted as a global scenario. Global types retain the friendly type syntax of binary session types while specifying dependencies and capturing complex causal chains of multiparty asynchronous interactions. A global type plays the role of a shared agreement among communication peers...

  3. Evaluation of lymphocytic exudative pleural effusion with pleural biopsy

    International Nuclear Information System (INIS)

    Khurram, M.; Jaffery, A.H.; Khar, Hamama-tul-Bushra; Malik, M.F.; Javed, S.; Burki, U.F.; Khan, B.A.; Ali, A.

    2002-01-01

    Objective: Evaluation of lymphocytic exudative pleural effusion by histopathological examination of pleural biopsy in patients with suspected tuberculous or malignant pleural effusion. Place and Duration of Study: The study was conducted at Pulmonology Department, Pakistan Institute of Medical Sciences, Islamabad and DHQ Teaching Hospital, Rawalpindi for two years 1999-2000. Subjects and Methods: A total of 120 patients with exudative pleural effusion underwent closed pleural biopsy with Abram's needle in standard way. Average 4 biopsy specimens were obtained in each patient which were examined histopathologically. Patients in whom a definite diagnosis was not possible were further investigated with repeat pleural biopsy, sputum examinations, bronchoscopy etc. Results definite histopathological diagnosis with pleural biopsy was possible in 59 (49.16% patients, including 13 diagnosed on repeat pleural biopsy. Two commonest diagnoses made were tuberculosis and adenocarcinoma, 64.40% and 13.55% respectively. Conclusion: Histopathological evaluation of pleural biopsy specimens can lead to diagnosis in 49.16% patients with exudative lymphocytic pleural effusion. (author)

  4. CT-guided percutaneous core needle biopsy in deep seated musculoskeletal lesions: a prospective study of 128 cases

    International Nuclear Information System (INIS)

    Puri, A.; Shingade, V.U.; Agarwal, M.G.; Anchan, C.; Juvekar, S.; Desai, S.; Jambhekar, N.A.

    2006-01-01

    Although large lesions of the limbs can easily be biopsied without image guidance, lesions in the spine, paraspinal area and pelvis are difficult to target, and benefit from CT guidance to improve the accuracy of targeting the lesion for biopsy purposes. A prospective study of CT-guided core needle biopsies for deep-seated musculoskeletal lesions was conducted at a referral cancer institute over a 4-year period with the aim of assessing the safety and efficacy of the procedure. From January 2000 to December 2003, 136 consecutive CT-guided biopsy sessions were undertaken for musculoskeletal lesions in 128 patients comprising 73 males and 55 females. The following data was recorded in all patients: demographic data, suspected clinicoradiological diagnosis, data related to core biopsy session (date, site, approach, total time required in minutes, number of cores, surgeon satisfaction with adequacy of cores), patient discomfort, complications, histopathology report and number of further sessions if material obtained during the first biopsy session was not confirmatory. The sample obtained during the biopsy session was considered inconclusive if, in the opinion of the pathologist, inadequate or non-representative tissue had been obtained. The diagnosis was considered inaccurate if the final histopathological diagnosis did not match with the biopsy diagnosis, or if subsequent clinicoradiological evaluation at follow up did not correlate with the biopsy diagnosis in those patients who were treated with modalities other than surgery. In 121 patients, a single session was sufficient to obtain representative material, whilst for six patients two sessions, and for one patient three sessions were necessary. The time taken for biopsy, including the pre-biopsy CT examination time, varied from 15 min to 60 min (median 30 min). For 110 bony lesions 116 sessions were required, and for 18 soft-tissue lesions 20 sessions were required. 108 biopsy sessions yielded a diagnosis, whilst

  5. Magnetic resonance imaging-targeted, 3D transrectal ultrasound-guided fusion biopsy for prostate cancer: Quantifying the impact of needle delivery error on diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Peter R., E-mail: pmarti46@uwo.ca [Department of Medical Biophysics, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Cool, Derek W. [Department of Medical Imaging, The University of Western Ontario, London, Ontario N6A 3K7, Canada and Robarts Research Institute, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Romagnoli, Cesare [Department of Medical Imaging, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Fenster, Aaron [Department of Medical Biophysics, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Department of Medical Imaging, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Robarts Research Institute, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Ward, Aaron D. [Department of Medical Biophysics, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Department of Oncology, The University of Western Ontario, London, Ontario N6A 3K7 (Canada)

    2014-07-15

    Purpose: Magnetic resonance imaging (MRI)-targeted, 3D transrectal ultrasound (TRUS)-guided “fusion” prostate biopsy intends to reduce the ∼23% false negative rate of clinical two-dimensional TRUS-guided sextant biopsy. Although it has been reported to double the positive yield, MRI-targeted biopsies continue to yield false negatives. Therefore, the authors propose to investigate how biopsy system needle delivery error affects the probability of sampling each tumor, by accounting for uncertainties due to guidance system error, image registration error, and irregular tumor shapes. Methods: T2-weighted, dynamic contrast-enhanced T1-weighted, and diffusion-weighted prostate MRI and 3D TRUS images were obtained from 49 patients. A radiologist and radiology resident contoured 81 suspicious regions, yielding 3D tumor surfaces that were registered to the 3D TRUS images using an iterative closest point prostate surface-based method to yield 3D binary images of the suspicious regions in the TRUS context. The probabilityP of obtaining a sample of tumor tissue in one biopsy core was calculated by integrating a 3D Gaussian distribution over each suspicious region domain. Next, the authors performed an exhaustive search to determine the maximum root mean squared error (RMSE, in mm) of a biopsy system that gives P ≥ 95% for each tumor sample, and then repeated this procedure for equal-volume spheres corresponding to each tumor sample. Finally, the authors investigated the effect of probe-axis-direction error on measured tumor burden by studying the relationship between the error and estimated percentage of core involvement. Results: Given a 3.5 mm RMSE for contemporary fusion biopsy systems,P ≥ 95% for 21 out of 81 tumors. The authors determined that for a biopsy system with 3.5 mm RMSE, one cannot expect to sample tumors of approximately 1 cm{sup 3} or smaller with 95% probability with only one biopsy core. The predicted maximum RMSE giving P ≥ 95% for each

  6. Magnetic resonance imaging-targeted, 3D transrectal ultrasound-guided fusion biopsy for prostate cancer: Quantifying the impact of needle delivery error on diagnosis.

    Science.gov (United States)

    Martin, Peter R; Cool, Derek W; Romagnoli, Cesare; Fenster, Aaron; Ward, Aaron D

    2014-07-01

    Magnetic resonance imaging (MRI)-targeted, 3D transrectal ultrasound (TRUS)-guided "fusion" prostate biopsy intends to reduce the ∼23% false negative rate of clinical two-dimensional TRUS-guided sextant biopsy. Although it has been reported to double the positive yield, MRI-targeted biopsies continue to yield false negatives. Therefore, the authors propose to investigate how biopsy system needle delivery error affects the probability of sampling each tumor, by accounting for uncertainties due to guidance system error, image registration error, and irregular tumor shapes. T2-weighted, dynamic contrast-enhanced T1-weighted, and diffusion-weighted prostate MRI and 3D TRUS images were obtained from 49 patients. A radiologist and radiology resident contoured 81 suspicious regions, yielding 3D tumor surfaces that were registered to the 3D TRUS images using an iterative closest point prostate surface-based method to yield 3D binary images of the suspicious regions in the TRUS context. The probabilityP of obtaining a sample of tumor tissue in one biopsy core was calculated by integrating a 3D Gaussian distribution over each suspicious region domain. Next, the authors performed an exhaustive search to determine the maximum root mean squared error (RMSE, in mm) of a biopsy system that gives P ≥ 95% for each tumor sample, and then repeated this procedure for equal-volume spheres corresponding to each tumor sample. Finally, the authors investigated the effect of probe-axis-direction error on measured tumor burden by studying the relationship between the error and estimated percentage of core involvement. Given a 3.5 mm RMSE for contemporary fusion biopsy systems,P ≥ 95% for 21 out of 81 tumors. The authors determined that for a biopsy system with 3.5 mm RMSE, one cannot expect to sample tumors of approximately 1 cm(3) or smaller with 95% probability with only one biopsy core. The predicted maximum RMSE giving P ≥ 95% for each tumor was consistently greater when using

  7. Magnetic resonance imaging-targeted, 3D transrectal ultrasound-guided fusion biopsy for prostate cancer: Quantifying the impact of needle delivery error on diagnosis

    International Nuclear Information System (INIS)

    Martin, Peter R.; Cool, Derek W.; Romagnoli, Cesare; Fenster, Aaron; Ward, Aaron D.

    2014-01-01

    Purpose: Magnetic resonance imaging (MRI)-targeted, 3D transrectal ultrasound (TRUS)-guided “fusion” prostate biopsy intends to reduce the ∼23% false negative rate of clinical two-dimensional TRUS-guided sextant biopsy. Although it has been reported to double the positive yield, MRI-targeted biopsies continue to yield false negatives. Therefore, the authors propose to investigate how biopsy system needle delivery error affects the probability of sampling each tumor, by accounting for uncertainties due to guidance system error, image registration error, and irregular tumor shapes. Methods: T2-weighted, dynamic contrast-enhanced T1-weighted, and diffusion-weighted prostate MRI and 3D TRUS images were obtained from 49 patients. A radiologist and radiology resident contoured 81 suspicious regions, yielding 3D tumor surfaces that were registered to the 3D TRUS images using an iterative closest point prostate surface-based method to yield 3D binary images of the suspicious regions in the TRUS context. The probabilityP of obtaining a sample of tumor tissue in one biopsy core was calculated by integrating a 3D Gaussian distribution over each suspicious region domain. Next, the authors performed an exhaustive search to determine the maximum root mean squared error (RMSE, in mm) of a biopsy system that gives P ≥ 95% for each tumor sample, and then repeated this procedure for equal-volume spheres corresponding to each tumor sample. Finally, the authors investigated the effect of probe-axis-direction error on measured tumor burden by studying the relationship between the error and estimated percentage of core involvement. Results: Given a 3.5 mm RMSE for contemporary fusion biopsy systems,P ≥ 95% for 21 out of 81 tumors. The authors determined that for a biopsy system with 3.5 mm RMSE, one cannot expect to sample tumors of approximately 1 cm 3 or smaller with 95% probability with only one biopsy core. The predicted maximum RMSE giving P ≥ 95% for each tumor was

  8. Muscle biopsies off-set normal cellular signaling in surrounding musculature

    DEFF Research Database (Denmark)

    Krag, Thomas O; Hauerslev, Simon; Dahlqvist, Julia R

    2013-01-01

    muscle tissue for at least 3 weeks after the biopsy was performed and magnetic resonance imaging suggests that an effect of a biopsy may persist for at least 5 months. Cellular signaling after a biopsy resembles what is seen in severe limb-girdle muscular dystrophy type 2I with respect to protein......Studies of muscle physiology and muscular disorders often require muscle biopsies to answer questions about muscle biology. In this context, we have often wondered if muscle biopsies, especially if performed repeatedly, would affect interpretation of muscle morphology and cellular signaling. We...... hypothesized that muscle morphology and cellular signaling involved in myogenesis/regeneration and protein turnover can be changed by a previous muscle biopsy in close proximity to the area under investigation. Here we report a case where a past biopsy or biopsies affect cellular signaling of the surrounding...

  9. Session 8: biofuels; Session 8: Les biocarburants

    Energy Technology Data Exchange (ETDEWEB)

    Botte, J.M.

    2006-01-15

    Here are given the summaries of the speeches of Mr Daniel Le Breton (Total): the transports of the future: the role of biofuels; of Mr Pierre Rouveirolles (Renault): the future expectations and needs; of Mr Frederic Monot (IFP): the developments of new generations of biofuels from biomass; of Mr Willem Jan Laan (Unilever): the use of bio resources for food and fuel: a fair competition? All these speeches have been presented at the AFTP yearly days (12-13 october 2005) on the session 8 concerning the biofuels. (O.M.)

  10. Image-Guided percutaneous biopsies with a biopsy gun

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Hwan; Lim, Hyo Keun; Kim, Eun Ah; Yun, Ku Sub; Bae, Sang Hoo; Shin, Hyung Sik [Hallym University College of Medicine, Seoul (Korea, Republic of)

    1994-07-15

    We report the results of image-guided percutaneous biopsies with a biopsy gun and evaluate the clinical usefulness. One hundred and five biopsies under ultrasonographic or fluoroscopic guidance were performed. Various anatomic sites were targeted(liver; 50, chest; 22, kidney; 12, pancreas; 8, intraperitoeum; 7, retroperitoneum; ). Obtained tissue was diagnostic in 98 of the 105 biopsies(93%). In each instance, representative core tissue specimens were obtained. Evaluation of the core tissue by pathologist revealed consistent, uniform specimens that contained significant crush artifact in no case. Five biopsies yielded inadequate tissue which were too small for histopathologic interpretation or were composed of necrotic debris. Two biopsies yielded adequate tissues, but tissues were not of the target. The diagnoses were malignancy in 77 biopsies and benign disease in 21 biopsies. No complications other than mild, localized discomfort were encountered except a transient hemoptysis and pneumothorax which was observed in two patients. Cutting biopsy with a biopsy gun provided sufficient amount of target tissue for an accurate diagnosis of malignant and benign disease. It was a safe and useful procedure for percutaneous biopsy.

  11. Radiologically Guided Bone Biopsy: Results of 502 Biopsies

    International Nuclear Information System (INIS)

    Ng, Chaan S.; Salisbury, Jonathan R.; Darby, Alan J.; Gishen, Philip

    1998-01-01

    Purpose: To analyze the results of 502 biopsies over a 19-year period for the purpose of highlighting the results that can be expected from such a large study, with emphasis on needle choice and anesthetic methods. Methods: The histological, cytological, and microbiological results of 477 patients who had 502 bone biopsies carried out between July 1977 and March 1996 were studied. Less than 5% of patients required second biopsies. There were almost equal numbers of males and females in the group. The lesions were visible radiologically and most of the biopsies were carried out by a single operator. The lesions were classified on their histopathological, cytopathological, and microbiological findings. Results: Tumors accounted for 40% of the biopsies, and infection for 16%. Biopsies which did not yield a 'positive' diagnosis accounted for 31%; these included specimens reported as normal, or as showing reactive changes, repair, remodelling, non-specific features, inflammation (but not clearly infective), or no evidence of malignancy or inflammation. Less than 4% of biopsies were incorrect, and some of these were re-biopsied. Conclusion: Bone biopsy is a valuable technique for positive diagnosis of malignancy or infection, as it enables a definitive plan for treatment and management of patients to be established. Exclusion of serious pathology is almost equally important. In principle, any osseous site can be biopsied using fluoroscopic or computed tomographic guidance. Care in the biopsy technique and selection of the bone needle is required

  12. US-guided percutaneous biopsies with a biopsy gun

    International Nuclear Information System (INIS)

    Ahn, In Oak; Kim, Hyung Jin; Kim, Jae Hyung; Lee, Goo; Jung, Sung Hoon

    1993-01-01

    Core tissue for histologic study is believed by many pathologist to be more diagnostic than material from needle aspiration. Recently introduced automatched biopsy gun simplifies core biopsies with increased quantity and quality of samples. Authors performed 38 percutaneous biopsies from 38 patients with 18G automated biopsy guns under US guide. Diagnostic target tissues were obtained in 33 biopsies(87%), inadequate tissues in 4(11%), and adequate but not of target tissue in 1(3%). There was no major complication requiring treatment, but pain needing analgesics and pain with nausea/vomiting were experienced in 2 and 1 biopsies respectively. Average number of needle passes was 1.5. We concluded that US guided gun biopsy was a easy and safe way to obtain tissue samples of good quantity and quality, especially useful in hospitals without constant availability of specialist in cytopathology

  13. Sonographically guided percutaneous muscle biopsy in diagnosis of neuromuscular disease: a useful alternative to open surgical biopsy.

    Science.gov (United States)

    O'Sullivan, Paul J; Gorman, Grainne M; Hardiman, Orla M; Farrell, Michael J; Logan, P Mark

    2006-01-01

    The purpose of this study was to evaluate the feasibility of sonographically guided percutaneous muscle biopsy in the investigation of neuromuscular disorders. Sonographically guided percutaneous needle biopsy of skeletal muscle was performed with a 14-gauge core biopsy system in 40 patients over a 24-month period. Patients were referred from the Department of Neurology under investigation for neuromuscular disorders. Sonography was used to find suitable tissue and to avoid major vascular structures. A local anesthetic was applied below skin only. A 3- to 4-mm incision was made. Three 14-gauge samples were obtained from each patient. All samples were placed on saline-dampened gauze and sent for neuropathologic analysis. As a control, we retrospectively assessed results of the 40 most recent muscle samples acquired via open surgical biopsy. With the use of sonography, 32 (80%) of 40 patients had a histologic diagnosis made via percutaneous needle biopsy. This included 26 (93%) of 28 patients with acute muscular disease and 6 (50%) of 12 patients with chronic disease. In the surgical group (all acute disease), 38 (95%) of 40 patients had diagnostic tissue attained. Sonographically guided percutaneous 14-gauge core skeletal muscle biopsy is a useful procedure, facilitating diagnosis in acute muscular disease. It provides results comparable with those of open surgical biopsy in acute muscular disease. It may also be used in chronic muscular disease but repeated or open biopsy may be needed.

  14. Nail biopsy: A user's manual

    Directory of Open Access Journals (Sweden)

    Chander Grover

    2018-01-01

    Full Text Available Nail biopsy is a procedure not routinely resorted to; but when indicated, it is often the only clue left for diagnosis. At such times, it pays to be conversant with it. It is an investigation that not only provides etiologic, diagnostic, and prognostic information but also aids in understanding the pathogenesis of nail diseases. It can be of therapeutic value, especially with respect to nail tumors. This article compiles the procedural techniques for nail biopsy of various types and attempts to summarize the evidence available in the literature. The objective of nail biopsy is to clinch a precise diagnosis of nail pathology with a simple and safe surgical procedure, avoiding pain or permanent nail damage. Patient selection is of utmost importance, wherein, the patient does not have typical skin lesions, yields inadequate information on routine nail investigations, and has no peripheral vascular compromise. The patient needs to be explained about the risks associated, the expected functional handicap, the time required for regrowth, a possibility of permanent nail dystrophy, and a possibility of not achieving a diagnosis even after the biopsy. Techniques and types of various nail biopsies are being discussed in this article. The specimen could be collected as an excision biopsy, punch biopsy, shave biopsy, or longitudinal biopsy. The trick lies in choosing the appropriate area for biopsy. Various biopsy types discussed in this article include nail plate biopsy (easiest and least scarring; nail bed biopsy (elliptical excision or punch; nail matrix biopsy (elliptical excision, punch excision (≤3 mm or tangential/shave excision; and nail fold biopsy. Complications reported along with means to minimize them are also discussed.

  15. Summary: Hadron dynamics sessions

    International Nuclear Information System (INIS)

    Carroll, A.S.; Londergan, J.T.

    1993-01-01

    Four sessions on Hadron Dynamics were organized at this Workshop. The first topic, QCD Exclusive Reactions and Color Transparency, featured talks by Ralston, Heppelman and Strikman; the second, QCD and Inclusive Reactions had talks by Garvey, Speth and Kisslinger. The third dynamics session, Medium Modification of Elementary Interactions had contributions from Kopeliovich, Alves and Gyulassy; the fourth session Pre-QCD Dynamics and Scattering, had talks by Harris, Myhrer and Brown. An additional joint Spectroscopy/Dynamics session featured talks by Zumbro, Johnson and McClelland. These contributions are reviewed briefly in this summary. Two additional joint sessions between Dynamics and η physics are reviewed by the organizers of the Eta sessions. In such a brief review there is no way the authors can adequately summarize the details of the physics presented here. As a result, they concentrate only on brief impressionistic sketches of the physics topics discussed and their interrelations. They include no bibliography in this summary, but simply refer to the talks given in more detail in the Workshop proceedings. They focus on topics which were common to several presentations in these sessions. First, nuclear and particle descriptions of phenomena are now clearly converging, in both a qualitative and quantitative sense; they show several examples of this convergence. Second, an important issue in hadron dynamics is the extent to which elementary interactions are modified in nuclei at high energies and/or densities, and they illustrate some of these medium effects. Finally, they focus on those dynamical issues where hadron facilities can make an important, or even a unique, contribution to the knowledge of particle and nuclear physics

  16. Usefulness of automated biopsy guns in image-guided biopsy

    International Nuclear Information System (INIS)

    Lee, Jung Hyung; Rhee, Chang Soo; Lee, Sung Moon; Kim, Hong; Woo, Sung Ku; Suh, Soo Jhi

    1994-01-01

    To evaluate the usefulness of automated biopsy guns in image-guided biopsy of lung, liver, pancreas and other organs. Using automated biopsy devices, 160 biopsies of variable anatomic sites were performed: Biopsies were performed under ultrasonographic(US) guidance in 95 and computed tomographic (CT) guidance in 65. We retrospectively analyzed histologic results and complications. Specimens were adequate for histopathologic diagnosis in 143 of the 160 patients(89.4%)-Diagnostic tissue was obtained in 130 (81.3%), suggestive tissue obtained in 13(8.1%), and non-diagnostic tissue was obtained in 14(8.7%). Inadequate tissue was obtained in only 3(1.9%). There was no statistically significant difference between US-guided and CT-guided percutaneous biopsy. There was no occurrence of significant complication. We have experienced mild complications in only 5 patients-2 hematuria and 2 hematochezia in transrectal prostatic biopsy, and 1 minimal pneumothorax in CT-guided percutaneous lung biopsy. All of them were resolved spontaneously. The image-guided biopsy using the automated biopsy gun was a simple, safe and accurate method of obtaining adequate specimen for the histopathologic diagnosis

  17. Usefulness of automated biopsy guns in image-guided biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Hyung; Rhee, Chang Soo; Lee, Sung Moon; Kim, Hong; Woo, Sung Ku; Suh, Soo Jhi [School of Medicine, Keimyung University, Daegu (Korea, Republic of)

    1994-12-15

    To evaluate the usefulness of automated biopsy guns in image-guided biopsy of lung, liver, pancreas and other organs. Using automated biopsy devices, 160 biopsies of variable anatomic sites were performed: Biopsies were performed under ultrasonographic(US) guidance in 95 and computed tomographic (CT) guidance in 65. We retrospectively analyzed histologic results and complications. Specimens were adequate for histopathologic diagnosis in 143 of the 160 patients(89.4%)-Diagnostic tissue was obtained in 130 (81.3%), suggestive tissue obtained in 13(8.1%), and non-diagnostic tissue was obtained in 14(8.7%). Inadequate tissue was obtained in only 3(1.9%). There was no statistically significant difference between US-guided and CT-guided percutaneous biopsy. There was no occurrence of significant complication. We have experienced mild complications in only 5 patients-2 hematuria and 2 hematochezia in transrectal prostatic biopsy, and 1 minimal pneumothorax in CT-guided percutaneous lung biopsy. All of them were resolved spontaneously. The image-guided biopsy using the automated biopsy gun was a simple, safe and accurate method of obtaining adequate specimen for the histopathologic diagnosis.

  18. Telepathology and Optical Biopsy

    Directory of Open Access Journals (Sweden)

    Olga Ferrer-Roca

    2009-01-01

    Full Text Available The ability to obtain information about the structure of tissue without taking a sample for pathology has opened the way for new diagnostic techniques. The present paper reviews all currently available techniques capable of producing an optical biopsy, with or without morphological images. Most of these techniques are carried out by physicians who are not specialized in pathology and therefore not trained to interpret the results as a pathologist would. In these cases, the use of telepathology or distant consultation techniques is essential.

  19. No need for biopsies

    DEFF Research Database (Denmark)

    Gjødsbøl, Kristine; Skindersoe, Mette E; Christensen, Jens Jørgen

    2011-01-01

    collected. After 4 weeks, additional biopsy and filter paper pad samples were collected. Bacteria were isolated and identified at species level by standard methods. The most common bacterial species detected was Staphylococcus aureus found in 89% of the ulcers. No methicillin-resistant S. aureus isolates...... were found. We did not find any significant differences regarding the bacterial species isolated between the three sampling techniques. However, using multiple techniques led to identification of more species. Our study suggests that it is sufficient to use swab specimens to identify the bacterial...

  20. Linearly Refined Session Types

    Directory of Open Access Journals (Sweden)

    Pedro Baltazar

    2012-11-01

    Full Text Available Session types capture precise protocol structure in concurrent programming, but do not specify properties of the exchanged values beyond their basic type. Refinement types are a form of dependent types that can address this limitation, combining types with logical formulae that may refer to program values and can constrain types using arbitrary predicates. We present a pi calculus with assume and assert operations, typed using a session discipline that incorporates refinement formulae written in a fragment of Multiplicative Linear Logic. Our original combination of session and refinement types, together with the well established benefits of linearity, allows very fine-grained specifications of communication protocols in which refinement formulae are treated as logical resources rather than persistent truths.

  1. Workshop: poster session

    International Nuclear Information System (INIS)

    Schell, W.R.; Colgan, P.A.

    1990-01-01

    The poster session consisted of a microcosm of projects encompassing the wide range of problems in the radioecology of natural and semi-natural ecosystems. The authors presented a brief resume of the poster at a plenary session during which highlights were pointed out. The range of studies covered microbial transfer, fungi, insects herbicides, lichens, solid speciation of cesium, soil properties, plant cover, transfer factors from soil to plants, uptake by sludge fertilizers, fertilizer remediation and compartmental models for soil-plant uptake. (author)

  2. Session 2: Machine studies

    International Nuclear Information System (INIS)

    Assmann, R.W.; Papotti, G.

    2012-01-01

    This document summarizes the talks and discussion that took place in the second session of the Chamonix 2012 workshop concerning results from machine studies performed in 2011. The session consisted of the following presentations: -) LHC experience with different bunch spacings by G. Rumolo; -) Observations of beam-beam effects in MDs in 2011 by W. Herr; -) Beam-induced heating/ bunch length/RF and lessons for 2012 by E. Metral; -) Lessons in beam diagnostics by R. Jones; -) Quench margins by M. Sapinski; and -) First demonstration with beam of the Achromatic Telescopic Squeeze (ATS) by S. Fartoukh. (authors)

  3. CT-guided biopsy with cutting-edge needle for the diagnosis of malignant lymphoma: Experience of 267 biopsies

    International Nuclear Information System (INIS)

    Agid, R.; Sklair-Levy, M.; Bloom, A.I.; Lieberman, S.; Polliack, A.; Ben-Yehuda, D.; Sherman, Y.; Libson, E.

    2003-01-01

    AIM: We performed a retrospective study of 267 core needle aspiration biopsies in order to estimate the accuracy of CT-guided aspiration core needle biopsies for the diagnosis and subsequent treatment of malignant lymphoma. MATERIALS AND METHODS: Between 1989 and 1999, 267 CT-guided core needle biopsies were performed in 241 patients with either primary or recurrent malignant lymphoma. Patients age ranged from 4--88 years. One hundred and sixty-six (62.2%) nodal and 101 (37.8%) extranodal aspiration biopsies were performed using either 18 G or 20 G Turner needles. Statistical method used was Chi-square analysis. RESULTS: An accurate histological diagnosis was made in 199 (82.5%) patients, the remaining 42 (17.4%) patients had non-diagnostic CT biopsies. Thirty-seven of them were diagnosed by a surgical biopsy, four by bone marrow biopsy and in one patient by paracentesis. One hundred and seventy-nine patients had non-Hodgkin's lymphoma (NHL) and 62 had Hodgkin's disease (HD); 23 (9.54%) patients underwent repeated CT biopsy which was diagnostic in 17 (73.9%) and non-diagnostic in six (26%). CONCLUSION: CT-guided aspiration core biopsies were sufficient to establish a diagnosis in lymphoproliferative disorders in 82.5% of cases. In the light of this experience we suggest that imaging-guided core needle biopsy be used as the first step in the work up of many patients with lymphoma Agid,R. et al. (2003). Clinical Radiology58, 143-147

  4. Are concurrent systematic cores needed at the time of targeted biopsy in patients with prior negative prostate biopsies?

    Science.gov (United States)

    Albisinni, S; Aoun, F; Noel, A; El Rassy, E; Lemort, M; Paesmans, M; van Velthoven, R; Roumeguère, T; Peltier, A

    2018-01-01

    MRI-guided targeted biopsies are advised in patients who have undergone an initial series of negative systematic biopsies, in whom prostate cancer (PCa) suspicion remains elevated. The aim of the study was to evaluate whether, in men with prior negative prostate biopsies, systematic cores are also warranted at the time of an MRI-targeted repeat biopsy. We enrolled patients with prior negative biopsy undergoing real time MRI/TRUS fusion guided prostate biopsy at our institute between 2014 and 2016. Patients with at least one index lesion on multiparametric MRI were included. All eligible patients underwent both systematic random biopsies (12-14 cores) and targeted biopsies (2-4 cores). The study included 74 men with a median age of 65 years, PSA level of 9.27ng/mL, and prostatic volume of 45ml. The overall PCa detection rate and the clinically significant cancer detection rate were 56.7% and 39.2%, respectively. Targeted cores demonstrated similar clinically significant PCa detection rate compared to systematic cores (33.8% vs. 28.4%, P=0.38) with significantly less tissue sampling. Indeed, a combination approach was significantly superior to a targeted-only in overall PCa detection (+16.7% overall detection rate, P=0.007). Although differences in clinically significant PCa detection were statistically non-significant (P=0.13), a combination approach did allow detecting 7 extra clinically significant PCas (+13.8%). In patients with elevated PSA and prior negative biopsies, concurrent systematic sampling may be needed at the time of targeted biopsy in order to maximize PCa detection rate. Larger studies are needed to validate our findings. 4. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  5. Diagnosing pancreatic cancer: the role of percutaneous biopsy and CT

    International Nuclear Information System (INIS)

    Amin, Z.; Theis, B.; Russell, R.C.G.; House, C.; Novelli, M.; Lees, W.R.

    2006-01-01

    Aims: To determine the sensitivity and complications of percutaneous biopsy of pancreatic masses, and whether typical computed tomography (CT) features of adenocarcinoma can reliably predict this diagnosis. Materials and methods: A 5 year retrospective analysis of percutaneous core biopsies of pancreatic masses and their CT features was undertaken. Data were retrieved from surgical/pathology databases; medical records and CT reports and images. Results: Three hundred and three patients underwent 372 biopsies; 56 of 87 patients had repeat biopsies. Malignancy was diagnosed in 276 patients, with ductal adenocarcinoma in 259 (85%). Final sensitivity of percutaneous biopsy for diagnosing pancreatic neoplasms was 90%; for repeat biopsy it was 87%. Complications occurred in 17 (4.6%) patients, in three of whom the complications were major (1%): one abscess, one duodenal perforation, one large retroperitoneal bleed. CT features typical of ductal adenocarcinoma were: hypovascular pancreatic mass with bile and/or pancreatic duct dilatation. Atypical CT features were: isodense or hypervascular mass, calcification, non-dilated ducts, cystic change, and extensive lymphadenopathy. Defining typical CT features of adenocarcinoma as true-positives, CT had a sensitivity of 68%, specificity of 95%, positive predictive value (PPV) of 98%, and negative predictive value of 41% for diagnosing pancreatic adenocarcinoma. Conclusion: Final sensitivity of percutaneous biopsy for establishing the diagnosis was 90%. CT features typical of pancreatic adenocarcinoma had high specificity and PPV. On some occasions, especially in frail patients with co-morbidity, it might be reasonable to assume a diagnosis of pancreatic cancer if CT features are typical, and biopsy only if CT shows atypical features

  6. Diagnosing pancreatic cancer: the role of percutaneous biopsy and CT

    Energy Technology Data Exchange (ETDEWEB)

    Amin, Z.; Theis, B.; Russell, R.C.G.; House, C.; Novelli, M.; Lees, W.R

    2006-12-15

    Aims: To determine the sensitivity and complications of percutaneous biopsy of pancreatic masses, and whether typical computed tomography (CT) features of adenocarcinoma can reliably predict this diagnosis. Materials and methods: A 5 year retrospective analysis of percutaneous core biopsies of pancreatic masses and their CT features was undertaken. Data were retrieved from surgical/pathology databases; medical records and CT reports and images. Results: Three hundred and three patients underwent 372 biopsies; 56 of 87 patients had repeat biopsies. Malignancy was diagnosed in 276 patients, with ductal adenocarcinoma in 259 (85%). Final sensitivity of percutaneous biopsy for diagnosing pancreatic neoplasms was 90%; for repeat biopsy it was 87%. Complications occurred in 17 (4.6%) patients, in three of whom the complications were major (1%): one abscess, one duodenal perforation, one large retroperitoneal bleed. CT features typical of ductal adenocarcinoma were: hypovascular pancreatic mass with bile and/or pancreatic duct dilatation. Atypical CT features were: isodense or hypervascular mass, calcification, non-dilated ducts, cystic change, and extensive lymphadenopathy. Defining typical CT features of adenocarcinoma as true-positives, CT had a sensitivity of 68%, specificity of 95%, positive predictive value (PPV) of 98%, and negative predictive value of 41% for diagnosing pancreatic adenocarcinoma. Conclusion: Final sensitivity of percutaneous biopsy for establishing the diagnosis was 90%. CT features typical of pancreatic adenocarcinoma had high specificity and PPV. On some occasions, especially in frail patients with co-morbidity, it might be reasonable to assume a diagnosis of pancreatic cancer if CT features are typical, and biopsy only if CT shows atypical features.

  7. Session 7: Reserve

    International Nuclear Information System (INIS)

    Bailey, R.; Crockford, G.

    2001-01-01

    The reserve session was devoted to some issues that came up through the workshop, which were grouped into three main areas: The Global Accelerator Network, Problems of stress and how to get organized to minimize them, What should an operations group be responsible for? This paper summarizes the discussions that took place. (author)

  8. Session 2: Availability

    CERN Document Server

    Uythoven, J

    2012-01-01

    This session concentrated on the main players affecting the availability of the LHC: the Quench Protection System (QPS), the cryogenics system, the regularly foreseen technical stops and the effect of radiation on equipment failures. A forecast for operation in 2012 was made for all these items.

  9. Summary of Session 3

    International Nuclear Information System (INIS)

    Fleischer, J.

    2004-01-01

    In Session 3, the speakers were dealing with the following topics: Automatization of Feynman Diagram Calculations (FDC), Event generators, Analytical approaches to FDC and various Mathematical innovations related to different physical problems. A more general, 'brainstorming', talk was given by J. Vermaseren as first talk

  10. Summary of Session III

    International Nuclear Information System (INIS)

    Furman, M.A.

    2002-01-01

    This is a summary of the talks presented in Session III ''Simulations of Electron-Cloud Build Up'' of the Mini-Workshop on Electron-Cloud Simulations for Proton and Positron Beams ECLOUD-02, held at CERN, 15-18 April 2002

  11. Abstracts of SIG Sessions.

    Science.gov (United States)

    Proceedings of the ASIS Annual Meeting, 1994

    1994-01-01

    Includes abstracts of 18 special interest group (SIG) sessions. Highlights include natural language processing, information science and terminology science, classification, knowledge-intensive information systems, information value and ownership issues, economics and theories of information science, information retrieval interfaces, fuzzy thinking…

  12. NSSS vendors session

    International Nuclear Information System (INIS)

    Anon.

    1982-01-01

    A transcription of a question and answer session at the 1982 Nuclear Commerce Conference was presented. Standardization of nuclear power plant design, and the effects it would have on Nuclear Regulatory Commission licensing and regulations, was of particular interest. Forecasts of the demand for nuclear power for the rest of this country were also discussed

  13. Fostering repeat donations in Ghana.

    Science.gov (United States)

    Owusu-Ofori, S; Asenso-Mensah, K; Boateng, P; Sarkodie, F; Allain, J-P

    2010-01-01

    Most African countries are challenged in recruiting and retaining voluntary blood donors by cost and other complexities and in establishing and implementing national blood policies. The availability of replacement donors who are a cheaper source of blood has not enhanced repeat voluntary donor initiatives. An overview of activities for recruiting and retaining voluntary blood donors was carried out. Donor records from mobile sessions were reviewed from 2002 to 2008. A total of 71,701 blood donations; 45,515 (63.5%) being voluntary donations with 11,680 (25%) repeat donations were collected during the study period. Donations from schools and colleges contributed a steady 60% of total voluntary whilst radio station blood drives increased contribution from 10 to 27%. Though Muslim population is less than 20%, blood collection was above the 30-donation cost-effectiveness threshold with a repeat donation trend reaching 60%. In contrast Christian worshippers provided donations. Repeat donation trends amongst school donors and radio blood drives were 20% and 70% respectively. Repeat donations rates have been variable amongst different blood donor groups in Kumasi, Ghana. The impact of community leaders in propagating altruism cannot be overemphasized. Programs aiming at motivating replacement donors to be repeat donors should be developed and assessed. Copyright 2009 The International Association for Biologicals. All rights reserved.

  14. Session 1 - discussion

    International Nuclear Information System (INIS)

    Wells, C.; Richards, K.M.; McKerrow, J.F.

    1991-01-01

    This discussion session of the Landfill Gas-Energy and Environment 90 Conference covered the landfill gas potential, the setting up of the Non-Fossil Fuel Obligation; anticipated developments in the post 1998 period, the problem of smell for those who live near a landfill, and the length of time a landfill site is productive in terms of gas evolution. Relevant regulations in California are briefly discussed. (author)

  15. Oral Biopsy: A Dental Gawk

    African Journals Online (AJOL)

    Sir,. Dermatologists are often confronted with neoplasms and diseases of the oral cavity. Although many may be reluctant to perform oral surgical procedures, a biopsy is often needed to establish a definitive diagnosis, and biopsy of the oral cavity is a safe and useful technique that can be easily employed by dermatologists.

  16. The accuracy of colposcopic biopsy

    DEFF Research Database (Denmark)

    Stoler, Mark H; Vichnin, Michelle D; Ferenczy, Alex

    2011-01-01

    We evaluated the overall agreement between colposcopically directed biopsies and the definitive excisional specimens within the context of three clinical trials. A total of 737 women aged 16-45 who had a cervical biopsy taken within 6 months before their definitive therapy were included. Per-prot...

  17. Liquid biopsy for brain tumors

    Science.gov (United States)

    Shankar, Ganesh M.; Balaj, Leonora; Stott, Shannon L.; Nahed, Brian; Carter, Bob S.

    2018-01-01

    Introduction Minimally invasive methods will augment the clinical approach for establishing the diagnosis or monitoring treatment response of central nervous system tumors. Liquid biopsy by blood or cerebrospinal fluid sampling holds promise in this regard. Areas covered In this literature review, the authors highlight recent studies describing the analysis of circulating tumor cells, cell free nucleic acids, and extracellular vesicles as strategies to accomplish liquid biopsy in glioblastoma and metastatic tumors. The authors then discuss the continued efforts to improve signal detection, standardize the liquid biopsy handling and preparation, develop platforms for clinical application, and establish a role for liquid biopsies in personalized medicine. Expert commentary As the technologies used to analyze these biomarkers continue to evolve, we propose that there is a future potential to precisely diagnose and monitor treatment response with liquid biopsies. PMID:28875730

  18. Value of percutaneous needle biopsy of small renal tumors in patients referred for cryoablation.

    Science.gov (United States)

    Iguchi, Toshihiro; Hiraki, Takao; Gobara, Hideo; Fujiwara, Hiroyasu; Sakurai, Jun; Matsui, Yusuke; Araki, Motoo; Nasu, Yasutomo; Kanazawa, Susumu

    2017-04-01

    To retrospectively evaluate the safety and diagnostic yield of needle biopsy of small renal tumors, and the clinical consequences of performing needle biopsy in patients referred for percutaneous cryoablation before their treatment. Biopsy was performed for 120 tumors (mean diameter, 2.2 cm) in 119 patients. All procedures were divided into diagnostic and non-diagnostic biopsies. Various variables were compared between the two groups. All cryoablation procedures were divided into two groups: procedures with or without simultaneous biopsy. The rates of benign or non-diagnostic tumors in each group were compared. After performing 120 initial and eight repeat biopsies, Grade 1 bleedings occurred in 44 cases. Six tumors were non-diagnostic and 114 were pathologically diagnosed. There were no significant variables between the diagnostic and non-diagnostic biopsies. Unnecessary cryoablation was avoided in nine benign lesions by performing biopsy in advance. Cryoablation performed simultaneously with biopsy included significantly more benign or non-diagnostic tumors than cryoablation performed after biopsy (15.2% vs. 1.4%; p = .01). Percutaneous biopsy of small renal tumors referred for cryoablation was a safe procedure with high diagnostic yield. The confirmation of pathological diagnosis prior to cryoablation is necessary because patients with benign tumors can avoid unnecessary treatment.

  19. Synchrony in Dyadic Psychotherapy Sessions

    Science.gov (United States)

    Ramseyer, Fabian; Tschacher, Wolfgang

    Synchrony is a multi-faceted concept used in diverse domains such as physics, biology, and the social sciences. This chapter reviews some of the evidence of nonverbal synchrony in human communication, with a main focus on the role of synchrony in the psychotherapeutic setting. Nonverbal synchrony describes coordinated behavior of patient and therapist. Its association with empathy, rapport and the therapeutic relationship has been pointed out repeatedly, yet close evaluation of empirical studies suggests that the evidence remains inconclusive. Particularly in naturalistic studies, research with quantitative measures of synchrony is still lacking. We introduce a new empirical approach for the study of synchrony in psychotherapies under field conditions: Motion Energy Analysis (MEA). This is a video-based algorithm that quantifies the amount of movement in freely definable regions of interest. Our statistical analysis detects synchrony on a global level, irrespective of the specific body parts moving. Synchrony thus defined can be considered as a general measure of movement coordination between interacting individuals. Data from a sequence of N = 21 therapy sessions taken from one psychotherapy dyad shows a high positive relationship between synchrony and the therapeutic bond. Nonverbal synchrony can thus be considered a promising concept for research on the therapeutic alliance. Further areas of application are discussed.

  20. ICALEPS 2005 : opening session

    CERN Multimedia

    Maximilien Brice

    2005-01-01

    ICALEPCS 2005, the tenth International Conference on Accelerator and Large Experimental Physics Control Systems, will be held in Geneva, Switzerland, 10-14 Oct. 2005 at the International Conference Center Geneva (CICG). ICALEPCS 2005 thus falls in the year that UNESCO has declared the "World Year of Physics". ICALEPCS covers all aspects of control and operation of Experimental Physics facilities such as particle accelerators, particle detectors, optical telescopes, radio telescopes, nuclear fusion facilities like Tokamaks, nuclear reactors, lasers, etc .... Opening session by . A. Daneels (CERN): Introducting ICALEPCS 2005 . C.Lamprecht (Republic & State of Geneva): Welcome speech . J. Lister (EPFL): Welcome speech . J. Engelen (CERN): The machine and experiment challenges of LHC

  1. 98th LHCC meeting Agenda OPEN Session and CLOSED Session

    CERN Document Server

    CERN. Geneva

    2009-01-01

    OPEN Session on Wednesday, 8 July at 9h00-11h00 in Main Auditorium, Live webcast, followed by CLOSED Session, Conference room 160-1-009 11h20-17h00. CLOSED Session continued on Thursday, 9 July at 9h00-12h30

  2. Mammographic scar for stereotaxic biopsy

    International Nuclear Information System (INIS)

    Guzman Tattis; Hincapie U, Ana Lucia; Patino P, Jairo Hernando

    1997-01-01

    It is reported the case of 56 years old woman who underwent a stereotactic biopsy because of having a circumscribed breast nodule. The histologic diagnosis was benign. After six months, during the mammographic control, it was noticed that the nodule showed irregular contours, because of that a surgical biopsy was performed. The histopathology was reported as benign. it is considered then, that the mammographic changes observed in the mammographic control are due to scar phenomenon after stereotactic biopsy. This findings has not been reported previously

  3. Ultrasound-Guided Breast Biopsy

    Science.gov (United States)

    ... over time. top of page What are the benefits vs. risks? Benefits The procedure is less invasive than surgical biopsy, ... risk of infection. The chance of infection requiring antibiotic treatment appears to be less than one in ...

  4. X-ray guided biopsy

    International Nuclear Information System (INIS)

    Casanova, R.; Lezana, A.H.; Pedrosa, C.S.

    1980-01-01

    Fine needle aspiration biopsy (FNAB) is now a routine procedure in many X-ray Departments. This paper presents the authors' experience with this technique in chest, abdominal and skeletal lesions. (Auth.)

  5. Stereotactic (Mammographically Guided) Breast Biopsy

    Science.gov (United States)

    ... over time. top of page What are the benefits vs. risks? Benefits The procedure is less invasive than surgical biopsy, ... risk of infection. The chance of infection requiring antibiotic treatment appears to be less than one in ...

  6. Testicular biopsy in prepubertal boys

    DEFF Research Database (Denmark)

    Faure, Alice; Bouty, Aurore; O'Brien, Mike

    2016-01-01

    No consensus exists regarding the precise role of testicular biopsy in prepubertal boys, although it is considered useful for assessing the potential consequences of undescended testes on fertility. Current scientific knowledge indicates that surgeons should broaden indications for this procedure...... for the preservation of fertility after gonadotoxic chemotherapy - even for prepubertal boys - are emerging. Cryopreservation of testicular tissue samples for the preservation of fertility - although still an experimental method at present - is appealing in this context. In our opinion, testicular biopsy...

  7. Percutaneous image-guided needle biopsy in children - summary of our experience with 57 children

    International Nuclear Information System (INIS)

    Sklair-Levy, M.; Lebensart, P.D.; Applbaum, Y.H.; Bar-Ziv, J.; Libson, E.; Ramu, N.; Freeman, A.; Gozal, D.; Gross, E.; Sherman, Y.

    2001-01-01

    Background: Percutaneous image-guided needle biopsy in children has been slower to gain acceptance than in adults where it is regarded as the standard clinical practice in screening suspicious masses. Objectives: To report our experience with percutaneous image-guided needle biopsy in the pediatric population and assess its clinical use, efficacy and limitations. Material and methods: Sixty-nine percutaneous image-guided needle biopsies were performed in 57 children. The age of the children ranged from 4 days to 14 years (mean 5.6 years). We used 16- to-20-gauge cutting-edge needles. Sixty-two biopsies were core-needle biopsies and 7 fine-needle aspiration biopsies. Results: There were 50 malignant lesions, 10 benign lesions and 2 infectious lesions. In 55 (88.7 %) lesions the needle biopsy was diagnostic. In 7 (11.3 %) the biopsy was non-diagnostic and the diagnosis was made by surgery. Core-needle biopsy was diagnostic in 47 of 50 (94 %) of the malignant solid tumors. In 3 out of 5 children with lymphoma, an accurate diagnosis was obtained with needle aspiration. Seven children underwent a repeated core-needle biopsy, (5 for Wilms' tumor and 2 for neuroblastoma) that was diagnostic in all cases. All the biopsies were performed without complications. Conclusion: Percutaneous image-guided needle biopsy is a simple, minimally invasive, safe and accurate method for the evaluation of children with suspicious masses. These data suggest that image-guided needle biopsy is an excellent tool for diagnosing solid tumors in the pediatric population. Negative studies should be considered nondiagnostic and followed by excisional surgical biopsies when clinical suspicion of malignancy is high. (orig.)

  8. Added value of second biopsy target in screen-detected widespread suspicious breast calcifications.

    Science.gov (United States)

    Falkner, Nathalie M; Hince, Dana; Porter, Gareth; Dessauvagie, Ben; Jeganathan, Sanjay; Bulsara, Max; Lo, Glen

    2018-06-01

    There is controversy on the optimal work-up of screen-detected widespread breast calcifications: whether to biopsy a single target or multiple targets. This study evaluates agreement between multiple biopsy targets within the same screen-detected widespread (≥25 mm) breast calcification to determine if the second biopsy adds value. Retrospective observational study of women screened in a statewide general population risk breast cancer mammographic screening program from 2009 to 2016. Screening episodes recalled for widespread calcifications where further views indicated biopsy, and two or more separate target areas were sampled within the same lesion were included. Percentage agreement and Cohen's Kappa were calculated. A total of 293317 women were screened during 761124 separate episodes with recalls for widespread calcifications in 2355 episodes. In 171 women, a second target was biopsied within the same lesion. In 149 (86%) cases, the second target biopsy result agreed with the first biopsy (κ = 0.6768). Agreement increased with increasing mammography score (85%, 86% and 92% for score 3, 4 and 5 lesions). Same day multiple biopsied lesions were three times more likely to yield concordant results compared to post-hoc second target biopsy cases. While a single target biopsy is sufficient to discriminate a benign vs. malignant diagnosis in most cases, in 14% there is added value in performing a second target biopsy. Biopsies performed prospectively are more likely to yield concordant results compared to post-hoc second target biopsy cases, suggesting a single prospective biopsy may be sufficient when results are radiological-pathological concordant; discordance still requires repeat sampling. © 2018 The Royal Australian and New Zealand College of Radiologists.

  9. Session Types at the Mirror

    Directory of Open Access Journals (Sweden)

    Luca Padovani

    2009-12-01

    Full Text Available We (redefine session types as projections of process behaviors with respect to the communication channels they use. In this setting, we give session types a semantics based on fair testing. The outcome is a unified theory of behavioral types that shares common aspects with conversation types and that encompass features of both dyadic and multi-party session types. The point of view we provide sheds light on the nature of session types and gives us a chance to reason about them in a framework where every notion, from well-typedness to the subtyping relation between session types, is semantically -rather than syntactically- grounded.

  10. Post biopsy pneumothorax: Risk factors and course

    International Nuclear Information System (INIS)

    Sanchez, J.A.; Retamar, J.A.; Blazquez, J.; Castano, J.C.

    1996-01-01

    The was to study the natural course of pneumothorax produced after aspiration biopsy in the attempt to differentiate those cases that will resolve spontaneously from those that will require drainage, and to assess the possible risk factors associated with the development of this entity. Eighty-nine CT-guided aspiration biopsies were performed in 80 patients. Control CT was done immediately after the procedure and 24 hours later. When pneumothorax persisted, CT was repeated at 48 h, 72 h, day 5 and day 7 or until a drainage tube was introduced. The cases of pneumothorax were classified as minimal, anterior or anterolateral. Seven variables were assessed as possible risk factors for its occurrence. Pneumothorax developed on 29 occasions (32.5%), requiring drainage in 12 cases (13.5%). In 20 patients (22%), pneumothorax occurred immediately, while in the remaining 9 (10%) it was detected in the 24 h CT scan. When studied according to type, drainage was required in 3 of the 19 cases of minimal or anterior pneumothorax (15%) and in 9 or the 10 cases of anterolateral location (90%) (p<0.0005). The mean thickness of the parenchyma punctured was 3.4 cm +- 2.2. cm when pneumothorax developed and 1.3 cm+- 2 cm when it did not (p<0.0001). There is a statistically significant association between the development of anterolateral pneumothorax and the need for chest drainage. The thickness of the punctured parenchyma is associated with the production of pneumothorax. 16 refs

  11. Mitochondrial Respiration after One Session of Calf Raise Exercise in Patients with Peripheral Vascular Disease and Healthy Older Adults.

    Science.gov (United States)

    van Schaardenburgh, Michel; Wohlwend, Martin; Rognmo, Øivind; Mattsson, Erney J R

    2016-01-01

    Mitochondria are essential for energy production in the muscle cell and for this they are dependent upon a sufficient supply of oxygen by the circulation. Exercise training has shown to be a potent stimulus for physiological adaptations and mitochondria play a central role. Whether changes in mitochondrial respiration are seen after exercise in patients with a reduced circulation is unknown. The aim of the study was to evaluate the time course and whether one session of calf raise exercise stimulates mitochondrial respiration in the calf muscle of patients with peripheral vascular disease. One group of patients with peripheral vascular disease (n = 11) and one group of healthy older adults (n = 11) were included. Patients performed one session of continuous calf raises followed by 5 extra repetitions after initiation of pain. Healthy older adults performed 100 continuous calf raises. Gastrocnemius muscle biopsies were collected at baseline and 15 minutes, one hour, three hours and 24 hours after one session of calf raise exercise. A multi substrate (octanoylcarnitine, malate, adp, glutamate, succinate, FCCP, rotenone) approach was used to analyze mitochondrial respiration in permeabilized fibers. Mixed-linear model for repeated measures was used for statistical analyses. Patients with peripheral vascular disease have a lower baseline respiration supported by complex I and they increase respiration supported by complex II at one hour post-exercise. Healthy older adults increase respiration supported by electron transfer flavoprotein and complex I at one hour and 24 hours post-exercise. Our results indicate a shift towards mitochondrial respiration supported by complex II as being a pathophysiological component of peripheral vascular disease. Furthermore exercise stimulates mitochondrial respiration already after one session of calf raise exercise in patients with peripheral vascular disease and healthy older adults. ClinicalTrials.gov NCT01842412.

  12. [Current situation and prospect of breast cancer liquid biopsy].

    Science.gov (United States)

    Zhou, B; Xin, L; Xu, L; Ye, J M; Liu, Y H

    2018-02-01

    Liquid biopsy is a diagnostic approach by analyzing body fluid samples. Peripheral blood is the most common sample. Urine, saliva, pleural effusion and ascites are also used. Now liquid biopsy is mainly used in the area of neoplasm diagnosis and treatment. Compared with traditional tissue biopsy, liquid biopsy is minimally invasive, convenient to sample and easy to repeat. Liquid biopsy mainly includes circulating tumor cells and circulating tumor DNA (ctDNA) detection. Detection of ctDNA requires sensitive and accurate methods. The progression of next-generation sequencing (NGS) and digital PCR promote the process of studies in ctDNA. In 2016, Nature published the result of whole-genome sequencing study of breast cancer. The study found 1 628 mutations of 93 protein-coding genes which may be driver mutations of breast cancer. The result of this study provided a new platform for breast cancer ctDNA studies. In recent years, there were many studies using ctDNA detection to monitor therapeutic effect and guide treatment. NGS is a promising technique in accessing genetic information and guiding targeted therapy. It must be emphasized that ctDNA detection using NGS is still at research stage. It is important to standardize ctDNA detection technique and perform prospective clinical researches. The time is not ripe for using ctDNA detection to guide large-scale breast cancer clinical practice at present.

  13. Oxidative stress response in trained men following repeated squats or sprints.

    Science.gov (United States)

    Bloomer, Richard J; Falvo, Michael J; Fry, Andrew C; Schilling, Brian K; Smith, Webb A; Moore, Christopher A

    2006-08-01

    The purpose of this investigation was to measure the oxidative stress response to similarly matched work bouts of squat and sprint exercise. Twelve anaerobically trained men performed six 10-s sprints and, on a separate occasion, repeated barbell squats to approximately equal the amount of work performed during the sprints. Blood lactate, heart rate, and perceived exertion was measured before and following each exercise bout. Muscle soreness, muscle force, and creatine kinase activity was determined preexercise and through 48 h of recovery. Desmin cytoskeletal protein was determined via muscle biopsy of the vastus lateralis before and at 24 h following each exercise. Plasma protein carbonyls (PC) and malondialdehyde (MDA) were measured as biomarkers of oxidative stress. Heart rate and perceived exertion was not different between exercise sessions (P > 0.05), although lactate was higher following sprinting compared with squatting (P = 0.002). Muscle soreness was greater for squatting than sprinting (P = 0.003) and reached a peak immediately postexercise for both sessions (P = 0.0003). Muscle force was unaffected by either exercise session (P > 0.05), and creatine kinase activity was elevated to a similar extent following both sessions. Desmin-negative fibers were virtually nonexistent after either exercise bout, indicating no loss of this cytoskeletal protein. Neither PC nor MDA was affected by the exercise (P > 0.05). These results suggest that in anaerobically trained men, the oxidative stress and muscle injury response to similarly matched anaerobic exercise bouts is minimal, and not different between exercise modes. Furthermore, when compared with previous literature on untrained subjects, the response is significantly attenuated, possibly because of adaptations occurring as a result of chronic, strenuous anaerobic training.

  14. Papillary lesions of the breast: comparison of the US-guided 14-gauge automated gun method and the 11-gauge directional vacuum-assisted biopsy method

    International Nuclear Information System (INIS)

    Ko, Eun Sook; Cho, Nariya; Yang, Sang Kyu; Kim, Do Youn; Moon, Woo Kyung

    2006-01-01

    The compare the outcomes of US-guided 14-gauge automated biopsy and 11-gauge vacuum-assisted biopsy for the papillary lesions of the breast. We retrospectively reviewed the US-guided core biopsies of 1,723 consecutive breast lesions that were treated from January 2003 to April 2005. Ninety-eight lesions (5.7%) were pathologically reported as papillary lesions. The biopsies were performed with using a 14-gauge automated gun on 65 lesions or with using an 11-gauge vacuum-assisted device on 33 lesions. Thirty-five lesions (54%, 35/65) of 14-gauge automated gun biopsies and 5 lesions (15%, 5/33) of 11-gauge vacuum-assisted biopsies underwent surgery. The histologic findings were compared with the surgical, imaging and follow-up findings. The histologic underestimation rate, the repeat biopsy rate and the false negative rate were compared between the two groups. The repeat biopsy rate was determined by dividing the total number of core biopsies into the number of repeat biopsies. 'ADH underestimation' was defined as a lesion yielding atypical ductal hyperplasia on percutaneous biopsy and carcinoma at surgery, and 'DCIS underestimation' was defined as a lesion yielding ductal carcinoma in situ on percutaneous biopsy and invasive carcinoma at surgery. The repeat biopsy rate was 42% (27/65) for the 14-gauge automated gun biopsies and 9.1% (3/33) for the 11-gauge vacuum-assisted biopsies. The ADH underestimation rate was 50% (7/14) for the 14-gauge automated gun biopsies and 0% (0/4) for the 11-gauge vacuum-assisted biopsies. The DCIS underestimation was 14% (1/7) for the 14-gauge automated gun biopsies and 0% (0/2) for the 11-gauge vacuum-assisted biopsies. The false negative rate was 0% for these two groups. For the papillary lesions of the breast, the outcomes of the US-guided core biopsies performed with the 11-gauge vacuum-assisted device were better than those of the biopsies performed with the 14-gauge automated gun, in terms of underestimation and repeat biopsy

  15. Ultrasound-guided forceps for pleural biopsy

    Directory of Open Access Journals (Sweden)

    Gamal Agmy

    2014-04-01

    Clinical implications: Ultrasound-guided forceps for pleural biopsy can overcome many of the limitations of the conventional needle biopsy procedures, provides multiple biopsy specimens of the parietal pleura that are inaccessible to the biopsy needle, and can be carried out easily and safely even in sick and obese patients. The diagnostic yield is nearly similar to thoracoscopy.

  16. Diagnostic yield and safety of closed needle pleural biopsy in exudative pleural effusion.

    Science.gov (United States)

    Rajawat, Govind Singh; Batra, Supreet; Takhar, Rajendra Prasad; Rathi, Lalit; Bhandari, Chand; Gupta, Manohar Lal

    2017-01-01

    Closed pleural biopsy was previously considered a procedure of choice in cases of undiagnosed pleural effusion with good efficacy. Currently, the closed pleural biopsy has been replaced by thoracoscopic biopsy but not easily available in resource-limited setups. The objective of this study was to analyze the diagnostic yield and safety of closed needle pleural biopsy in exudative pleural effusion and assessment of patients' characteristics with the yield of pleural biopsy. This was a cross-sectional study. This study was conducted at Institute of Respiratory Diseases, SMS Medical College, Jaipur, a tertiary care center of West India. A total of 250 cases of pleural effusion were evaluated with complete pleural fluid biochemical, microbiological, and cytological examination. Out of these 250 patients, 59 were excluded from the study as the diagnosis could be established on initial pleural fluid examination. The remaining (191) patients were considered for closed pleural biopsy with Abrams pleural biopsy needle. The main outcome measure was diagnostic yield in the form of confirming diagnosis. Out of the 191 patients with exudative lymphocytic pleural effusion, 123 (64.40%) were diagnosed on the first pleural biopsy. Among the remaining 68 patients, 22 patients had repeat pleural biopsy with a diagnostic yield of 59.9%. The overall pleural biopsy could establish the diagnosis in 136 (71.20%) patients with pleural effusion. The most common diagnosis on pleural biopsy was malignancy followed by tuberculosis. Closed pleural biopsy provides diagnostic yield nearly comparative to thoracoscopy in properly selected patients of pleural effusions. In view of good yield, low cost, easy availability, and very low complication rate, it should be used routinely in all cases of undiagnosed exudative lymphocytic pleural effusion. There was no comparison with a similar group undergoing thoracoscopic pleural biopsy.

  17. Sugar and acid interconversion in tomato fruits based on biopsy sampling of locule gel and pericarp tissue

    NARCIS (Netherlands)

    Schouten, R.E.; Woltering, E.J.; Tijskens, L.M.M.

    2016-01-01

    This study deals with quantifying sugar and acids levels important for the perceived taste of tomatoes (Solanum lycopersicum). Sugar and acids levels were measured repeatedly on the same tomato using tissue samples obtained with a biopsy needle in combination with HPLC protocols. Biopsies of

  18. Tissue Biopsies in Diabetes Research

    DEFF Research Database (Denmark)

    Højlund, Kurt; Gaster, Michael; Beck-Nielsen, Henning

    2007-01-01

    resistance of glucose disposal and glycogen synthesis in this tissue are hallmark features of type 2 diabetes in humans (2,3). During the past two decades, we have carried out more than 1200 needle biopsies of skeletal muscle to study the cellular mechanisms underlying insulin resistance in type 2 diabetes....... Together with morphological studies, measurement of energy stores and metabolites, enzyme activity and phosphorylation, gene and protein expression in skeletal muscle biopsies have revealed a variety of cellular abnormalities in patients with type 2 diabetes and prediabetes. The possibility to establish...... and gene expression profiling on skeletal muscle biopsies have pointed to abnormalities in mitochondrial oxidative phosphorylation in type 2 diabetes. These novel insights will inevitably cause a renewed interest in studying skeletal muscle. This chapter reviews our experience to date and gives a thorough...

  19. Risk score predicts high-grade prostate cancer in DNA-methylation positive, histopathologically negative biopsies.

    Science.gov (United States)

    Van Neste, Leander; Partin, Alan W; Stewart, Grant D; Epstein, Jonathan I; Harrison, David J; Van Criekinge, Wim

    2016-09-01

    Prostate cancer (PCa) diagnosis is challenging because efforts for effective, timely treatment of men with significant cancer typically result in over-diagnosis and repeat biopsies. The presence or absence of epigenetic aberrations, more specifically DNA-methylation of GSTP1, RASSF1, and APC in histopathologically negative prostate core biopsies has resulted in an increased negative predictive value (NPV) of ∼90% and thus could lead to a reduction of unnecessary repeat biopsies. Here, it is investigated whether, in methylation-positive men, DNA-methylation intensities could help to identify those men harboring high-grade (Gleason score ≥7) PCa, resulting in an improved positive predictive value. Two cohorts, consisting of men with histopathologically negative index biopsies, followed by a positive or negative repeat biopsy, were combined. EpiScore, a methylation intensity algorithm was developed in methylation-positive men, using area under the curve of the receiver operating characteristic as metric for performance. Next, a risk score was developed combining EpiScore with traditional clinical risk factors to further improve the identification of high-grade (Gleason Score ≥7) cancer. Compared to other risk factors, detection of DNA-methylation in histopathologically negative biopsies was the most significant and important predictor of high-grade cancer, resulting in a NPV of 96%. In methylation-positive men, EpiScore was significantly higher for those with high-grade cancer detected upon repeat biopsy, compared to those with either no or low-grade cancer. The risk score resulted in further improvement of patient risk stratification and was a significantly better predictor compared to currently used metrics as PSA and the prostate cancer prevention trial (PCPT) risk calculator (RC). A decision curve analysis indicated strong clinical utility for the risk score as decision-making tool for repeat biopsy. Low DNA-methylation levels in PCa-negative biopsies led

  20. Formal description of the OSI session layer: session service

    NARCIS (Netherlands)

    van Sinderen, Marten J.; van Eijk, P.H.J.; Vissers, C.A.; Diaz, M.

    1989-01-01

    The LOTOS formal description of the OSI session service is presented on basis of specification samples from the full description, giving account of how specification styles and session service architectural elements are reflected in the description. Both information (data types) and process

  1. [The role of a single PCA3 test before a first negative prostate biopsy: 5-year follow-up].

    Science.gov (United States)

    Bernardeau, S; Charles, T; Fromont-Hankard, G; Irani, J

    2017-04-01

    We report a 5-year follow-up of a cohort of patients who underwent a first prostate biopsy following a prostate cancer antigen 3 (PCA3) test. We reviewed consecutive patients who had in 2008 a single urinary PCA3 test using the Gen-Probe ® assay before a first prostate biopsy for a prostate-specific antigen (PSA) between 3 and 20ng/mL and/or a suspicious digital rectal examination. PCA3 performances were analyzed in 2008 and then in 2013 after taking into account the results of repeat biopsies. At initial biopsy in 2008, among the 125 patients study cohort, prostate cancer was diagnosed in 47 patients (37.6%). Abnormal digital rectal exam, PSA density, prostate volume and PCA3 score were significantly associated with prostate cancer diagnosis. PCA3 area under the curve of the receiver operating curve was 0.67 [95%CI: 0.57-0.76] with an optimal threshold of PCA3 in this sample of 24 units. During the 5-year follow-up, among the 78 patients with a negative prostate biopsy in 2008, 23 (29.5%) had a repeat prostate biopsy of whom 14 were diagnosed with prostate cancer. PCA3 score measured in 2008 was associated with prostate cancer diagnosis (P=0.002). All 9 patients with a negative repeat prostate biopsy had a PCA3 score below the cut-off while this was the case in only 2 patients among the 14 with a positive repeat prostate biopsy. The results of a single PCA3 test before a first prostate biopsy seems to be a useful aid in deciding whether to perform a repeat biopsy. 4. Copyright © 2017. Published by Elsevier Masson SAS.

  2. Biopsy techniques for intraocular tumors

    Directory of Open Access Journals (Sweden)

    Pukhraj Rishi

    2016-01-01

    Full Text Available Biopsy involves the surgical removal of a tissue specimen for histopathologic evaluation. Most intraocular tumors are reliably diagnosed based on the clinical evaluation or with noninvasive diagnostic techniques. However, accurately diagnosing a small percentage of tumors can be challenging. A tissue biopsy is thus needed to establish a definitive diagnosis and plan the requisite treatment. From fine-needle aspiration biopsy (FNAB to surgical excision, all tissue collection techniques have been studied in the literature. Each technique has its indications and limitations. FNAB has been reported to provide for 88-95% reliable and safe ophthalmic tumor diagnosis and has gained popularity for prognostic purposes and providing eye conserving treatment surgeries. The technique and instrumentation for biopsy vary depending upon the tissue involved (retina, choroid, subretinal space, vitreous, and aqueous, suspected diagnosis, size, location, associated retinal detachment, and clarity of the media. The cytopathologist confers a very important role in diagnosis and their assistance plays a key role in managing and planning the treatment for malignancies.

  3. Gastric tissue biopsy and culture

    Science.gov (United States)

    ... symptoms may include: Loss of appetite or weight loss Nausea and vomiting Pain in the upper part of the belly Black stools Vomiting blood or coffee ground-like material A gastric tissue biopsy and culture can help detect: Cancer Infections, most commonly Helicobacter ...

  4. Review for session K - benchmarks

    International Nuclear Information System (INIS)

    McCracken, A.K.

    1980-01-01

    Eight of the papers to be considered in Session K are directly concerned, at least in part, with the Pool Critical Assembly (P.C.A.) benchmark at Oak Ridge. The remaining seven papers in this session, the subject of this review, are concerned with a variety of topics related to the general theme of Benchmarks and will be considered individually

  5. Impact of Simulation-Based Training on Radiology Trainee Education in Ultrasound-Guided Breast Biopsies.

    Science.gov (United States)

    Roark, Ashley A; Ebuoma, Lilian O; Ortiz-Perez, Tamara; Sepulveda, Karla A; Severs, Frederick J; Wang, Tao; Benveniste, Ana Paula; Sedgwick, Emily L

    2017-12-05

    The aim of this study is to determine the impact of a simulation-based ultrasound-guided (USG) breast biopsy training session on radiology trainee procedural knowledge, comfort levels, and overall procedural confidence and anxiety. Twenty-one diagnostic radiology residents from a single academic institution were recruited to participate in an USG breast biopsy training session. The residents filled out a questionnaire before and after the training session. Ten multiple-choice questions tested general knowledge in diagnostic breast ultrasound and USG breast biopsy concepts. Subjective comfort levels with ultrasound machine and biopsy device functionality, patient positioning, proper biopsy technique, image documentation, needle safety and overall procedural confidence and anxiety levels were reported on a 5-point Likert scale before and after training. Participants demonstrated significant improvement in number of correctly answered general knowledge questions after training (P simulation-based USG breast biopsy training session may improve radiology trainee procedural knowledge, comfort levels, and overall procedural confidence. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  6. The Role of Biopsy in Pediatric Dermatopathology

    Directory of Open Access Journals (Sweden)

    Fatma Şule Afşa

    2011-09-01

    Full Text Available Background and Design: Pediatric dermatology is characterized by skin disorders which have frequencies different from those in adults. Skin biopsies are necessary for differential diagnosis and clinicopathologic correlation is very important. The aim of this study was to evaluate retrospectively the pediatric dermatology cases in whom biopsy was performed for differential diagnosis and to investigate the contribution of biopsy to diagnosis of skin disorders. Material and Methods: The cases from whom biopsy was taken in the pediatric dermatology clinic during a three-year period were evaluated retrospectively for pre-diagnoses, biopsy diagnoses, and success of biopsies.Results: Two hundred thirteen (1.7% skin biopsies had been taken from a total of 12420 patients. Henoch-Schönlein purpura, psoriasis, pityriasis lichenoides, pityriasis rosea, lichen planus, pityriasis rubra pilaris, erythema multiforme, atopic dermatitis, granuloma annulare, and pigmented purpuric dermatosis were the most frequent skin disorders diagnosed dermatopathologically. In a total of 120 (56.3% cases, the biopsy diagnosis was within the pre-diagnosis and a biopsy consistency was present. In 25 (11.7% cases, biopsy had no contribution to the differential diagnosis. An absolutely different diagnosis which was incompatible with the pre-diagnosis had been reported in 10 (4.6% cases. Conclusion: In pediatric dermatology, skin biopsy is very helpful for the differential diagnosis. An easy biopsy procedure for the patient, an effective designation of biopsy indication, a good dermatopathologic correlation and an experienced team of pediatric dermatopathology increase the success of skin biopsies.

  7. Retroperitoneoscopic renal biopsy in children

    Directory of Open Access Journals (Sweden)

    Carlos M. Jesus

    2007-08-01

    Full Text Available OBJECTIVE: We present our experience in a series of 17 consecutive pediatric patients submitted to retroperitoneal laparoscopic renal biopsy. MATERIALS AND METHODS: Retroperitoneal laparoscopic renal biopsy (LRB was performed in 5 boys and 12 girls. Mean age was 8.1 years and age range from 2 to 12. Two or three trocars were used to expose the inferior pole of the kidney, remove enough cortical parenchymal specimen and fulgurate the biopsy site. Assessment included surgical time, estimated blood loss, hospitalization period, analgesia requirements, complications and number of glomeruli present in the specimen. RESULTS: LRB was successfully performed in all 15 patients (88%. In two cases, LRB was not possible to be performed. One patient was converted to a transperitoneal laparoscopy due to tear in the peritoneum. The other patient had had previous abdominal surgery and, during retroperitoneal balloon dilation, the peritoneum was opened and the open biopsy was performed. A third patient had postoperatively a perirenal hematoma, which was solved spontaneously. Complication rate was 17.6% (3/17 cases. Mean operative time was 65 minutes, while mean estimated blood loss was 52 mL, mean hospital stay was 2.2 days and mean analgesic requirement was 100 mg of tramadol. The mean number of glomeruli present in the specimen was 60. CONCLUSION: Retroperitoneal laparoscopic renal biopsy in children is a simple, safe. Bleeding is still the most common complication. However, direct vision usually allows a safe control of this drawback. In our institution, laparoscopic approach is the chosen procedure in pediatric patients older than one - year - old.

  8. Repeated stress exposure causes strain-dependent shifts in the behavioral economics of cocaine in rats

    NARCIS (Netherlands)

    Groblewski, Peter A.; Zietz, Chad; Willuhn, Ingo; Phillips, Paul E. M.; Chavkin, Charles

    2015-01-01

    Cocaine-experienced Wistar and Wistar Kyoto (WKY) rats received four daily repeated forced swim stress sessions (R-FSS), each of which preceded 4-hour cocaine self-administration sessions. Twenty-four hours after the last swim stress, cocaine valuation was assessed during a single-session threshold

  9. CT-guided biopsies and drainage

    International Nuclear Information System (INIS)

    Scheppers, I.; Wollschlaeger, D.

    2011-01-01

    Following the implementation of computed tomography (CT) or ultrasound-guided biopsy of solid tumors and the puncture and drainage of liquid processes, the number of surgical open biopsies and curative operations for abscess drainage has declined. Such CT-guided interventions are performed in nearly every organ. Instead of aspiration biopsies, more and more core biopsies are being performed to allow histopathological evaluation and thus allowing targeted therapy. This article is intended to give a general overview of techniques, materials, indications and contraindications. Ultrasound-guided biopsies as well as large bore vacuum biopsies of the breast are not included in this review. (orig.) [de

  10. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking.......To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  11. Significant molecular and systemic adaptations after repeated sprint training in hypoxia.

    Directory of Open Access Journals (Sweden)

    Raphael Faiss

    Full Text Available While intermittent hypoxic training (IHT has been reported to evoke cellular responses via hypoxia inducible factors (HIFs but without substantial performance benefits in endurance athletes, we hypothesized that repeated sprint training in hypoxia could enhance repeated sprint ability (RSA performed in normoxia via improved glycolysis and O(2 utilization. 40 trained subjects completed 8 cycling repeated sprint sessions in hypoxia (RSH, 3000 m or normoxia (RSN, 485 m. Before (Pre- and after (Post- training, muscular levels of selected mRNAs were analyzed from resting muscle biopsies and RSA tested until exhaustion (10-s sprint, work-to-rest ratio 1:2 with muscle perfusion assessed by near-infrared spectroscopy. From Pre- to Post-, the average power output of all sprints in RSA was increased (p<0.01 to the same extent (6% vs 7%, NS in RSH and in RSN but the number of sprints to exhaustion was increased in RSH (9.4±4.8 vs. 13.0±6.2 sprints, p<0.01 but not in RSN (9.3±4.2 vs. 8.9±3.5. mRNA concentrations of HIF-1α (+55%, carbonic anhydrase III (+35% and monocarboxylate transporter-4 (+20% were augmented (p<0.05 whereas mitochondrial transcription factor A (-40%, peroxisome proliferator-activated receptor gamma coactivator 1α (-23% and monocarboxylate transporter-1 (-36% were decreased (p<0.01 in RSH only. Besides, the changes in total hemoglobin variations (Δ[tHb] during sprints throughout RSA test increased to a greater extent (p<0.01 in RSH. Our findings show larger improvement in repeated sprint performance in RSH than in RSN with significant molecular adaptations and larger blood perfusion variations in active muscles.

  12. Immunoglobulin deposits in peripheral nerve endings detected by skin biopsy in patients with IgM M proteins and neuropathy

    DEFF Research Database (Denmark)

    Jønsson, V; Jensen, T S; Friis, M L

    1987-01-01

    biopsies provide a simple effective method of detecting immunoglobulin binding to peripheral nerves in patients suspected of having an autoimmune neuropathy. In contrast to sural nerve biopsy, skin biopsy does not cause sensory loss or pain in a denervated area and can easily be repeated.......Immunofluorescence studies of sural nerve and skin biopsies from three patients with IgM M proteins and clinical neuropathy showed that IgM M protein was bound to the nerve myelin in two patients and by the peri- and endoneurium in one. It is suggested that immunohistochemical studies of skin...

  13. Ultrasound guided percutaneous fine needle aspiration biopsy ...

    African Journals Online (AJOL)

    )-guided percutaneous fine needle aspiration biopsy (PFNAB)/US-guided percutaneous needle core biopsy (PNCB) of abdominal lesions is efficacious in diagnosis, is helpful in treatment choice, to evaluate whether various other investigations ...

  14. Right Ventricular Pseudoaneurysm Following Endomyocardial Biopsy.

    Science.gov (United States)

    Pita; Santos; Manteiga; Rodriguez; Beiras

    1996-03-01

    Ventricular perforation is an unusual complication after endomyocardial biopsy in heart transplanted patients. We report a case of asymptomatic right ventricular perforation and pseudoaneurysm formation, secondary to endomyocardial biopsy, diagnosed by angiography. The spontaneous obliteration of the pseudoaneurysm was observed.

  15. Neuronavigator-guided cerebral biopsy.

    Science.gov (United States)

    Koivukangas, J; Louhisalmi, Y; Alakuijala, J; Oikarinen, J

    1993-01-01

    Neuronavigators are new dynamic interactive instruments that use on-line computers to orient imaging data to the surgical field and guide the neurosurgeon to his target. We have been working since 1987 on a neuronavigator that serves not only as a precise pointer, but also as a dynamic arm that can be used to hold instruments, such as biopsy guides. The neuronavigator arm consists of six joints with optical encoders and is attached to the Mayfield headholder. The arm is connected to a workstation running customized 3D image graphics software. Special instruments and surgical technique have been developed. Here, we report on early clinical experience with ten biopsy procedures: 4 low-grade and 3 high-grade astrocytomas, one craniopharyngioma and one chronic intracerebral haematoma and intracerebral cyst, both of the latter with surrounding tumour suspect tissue. In all glioma cases serial biopsies were taken from optimal sites under ultrasound imaging control. Eight cases showed representative tumour tissue, while in two cases neoplasia was ruled out. The neuronavigator proved to be versatile, allowing comprehensive imaging data to be adapted to the surgical field.

  16. Aortography following subdiaphragmal aortic biopsy

    International Nuclear Information System (INIS)

    Schimmler, J.

    1982-01-01

    A juxtaposition of the subdiaphragmal and infrarenal translumbar aortic biopsy sites showed decisive advantages in favour of the higher site: a more stable position because of better anatomic fixation and rarer incidence of vascular alterations, a wider vascular lumen. Disadvantages lie in the fact that the large visceral arteries (especially Tr. coeliacus) branch off nearly and in the close anatomic relationship to large abdominal organs and the thoracal region. Evaluation of the radiographical image of the vascular tree after subdiaphragmal aortic biopsy showed an average 82% of the vessels to the area of the Knees to be assessable (renal arteries approximately 93%, popliteal arteries approximately 70%). Beyong, the method proved unsatisfactory: 52% of the vessels could not, or not safety, be evaluated. A relatively broad spectrum of indications by comparison with transfemoral catheter aortography had no influence on the rate of complications with reference to either method. A comparison of the topographic conditions shows the need for even more scrupulons observation of the technique in subdiaphragmal biopsy than in the infrarenal one. To sum up the results obtained, subdiaphregmal translumbar aortography is to be preferred to the infrarenal one where transfemoral catheter aortography is contra-indicated, within the limits mentioned. (orig.) [de

  17. Comparison of CT and PET/CT for biopsy guidance in oncological patients

    International Nuclear Information System (INIS)

    Cerci, Juliano J.; Bogoni, Mateos; Cunha Pereira, Carlos; Cerci, Rodrigo J.; Krauzer, Cassiano; Vicente Vitola, Joao; Tabacchi, Elena; Fanti, Stefano; Delbeke, Dominique; Giacometti Sakamoto, Danielle

    2017-01-01

    To compare FDG PET/CT and CT for the guidance of percutaneous biopsies with histological confirmation of lesions. We prospectively evaluated 323 patients of whom 181 underwent FDG PET/CT-guided biopsy (total 188 biopsies) and 142 underwent CT-guided biopsy (total 146 biopsies). Biopsies were performed using the same PET/CT scanner with a fluoroscopic imaging system. Technical feasibility, clinical success and complication rates in the two groups were evaluated. Of the 188 biopsies with PET/CT guidance, 182 (96.8%) were successful with conclusive tissue samples obtained and of the 146 biopsies with CT guidance, 137 (93.8%) were successful. Therefore, 6 of 188 biopsies (3.1%) with PET/CT guidance and 9 of 146 (6.1%) with CT guidance were inconclusive (p = 0.19). Due to inconclusive histological results, 4 of the 188 lesions (2.1%) were rebiopsied with PET/CT guidance and 3 of 146 lesions (2.0%) were rebiopsied with CT guidance. Histology demonstrated that 142 of 188 lesions (75.5%) were malignant, and 40 (21.2%) were benign in the PET/CT-guided group, while 89 of 146 lesions (60.9%) were malignant and 48 (32.8%) were benign in the CT-guided group (p = 0.004 and 0.01, respectively). Patients with a histological diagnosis of benign lesion had no recurrence of disease with a minimum of 6 months follow-up. Of the 188 PET/CT-guided biopsies, 6 (3.1%) were repeat biopsies due to a previous nondiagnostic CT-guided biopsy performed in a different diagnostic centre. The interval between the two biopsies was less than a month in all cases. Histology revealed five malignant lesions and one benign lesion among these. The complication rate in the PET/CT-guided biopsy group was 12.7% (24 of 188), while in the CT-guided group, was 9.5% (14 of 146, p = 0.26). Therefore, there was no significant difference in complication rates between PET/CT and CT guidance. PET/CT-guided biopsy is already known to be a feasible and accurate method in the diagnostic work-up of suspected malignant

  18. Comparison of CT and PET/CT for biopsy guidance in oncological patients

    Energy Technology Data Exchange (ETDEWEB)

    Cerci, Juliano J.; Bogoni, Mateos; Cunha Pereira, Carlos; Cerci, Rodrigo J.; Krauzer, Cassiano; Vicente Vitola, Joao [Quanta - Diagnostico e Terapia, Curitiba, PR (Brazil); Tabacchi, Elena; Fanti, Stefano [University Hospital S. Orsola-Malpighi, Nuclear Medicine Department, Bologna (Italy); Delbeke, Dominique [Vanderbilt University, Nashville, TN (United States); Giacometti Sakamoto, Danielle [Byori - Laboratorio de Patologia, Curitiba (Brazil)

    2017-08-15

    To compare FDG PET/CT and CT for the guidance of percutaneous biopsies with histological confirmation of lesions. We prospectively evaluated 323 patients of whom 181 underwent FDG PET/CT-guided biopsy (total 188 biopsies) and 142 underwent CT-guided biopsy (total 146 biopsies). Biopsies were performed using the same PET/CT scanner with a fluoroscopic imaging system. Technical feasibility, clinical success and complication rates in the two groups were evaluated. Of the 188 biopsies with PET/CT guidance, 182 (96.8%) were successful with conclusive tissue samples obtained and of the 146 biopsies with CT guidance, 137 (93.8%) were successful. Therefore, 6 of 188 biopsies (3.1%) with PET/CT guidance and 9 of 146 (6.1%) with CT guidance were inconclusive (p = 0.19). Due to inconclusive histological results, 4 of the 188 lesions (2.1%) were rebiopsied with PET/CT guidance and 3 of 146 lesions (2.0%) were rebiopsied with CT guidance. Histology demonstrated that 142 of 188 lesions (75.5%) were malignant, and 40 (21.2%) were benign in the PET/CT-guided group, while 89 of 146 lesions (60.9%) were malignant and 48 (32.8%) were benign in the CT-guided group (p = 0.004 and 0.01, respectively). Patients with a histological diagnosis of benign lesion had no recurrence of disease with a minimum of 6 months follow-up. Of the 188 PET/CT-guided biopsies, 6 (3.1%) were repeat biopsies due to a previous nondiagnostic CT-guided biopsy performed in a different diagnostic centre. The interval between the two biopsies was less than a month in all cases. Histology revealed five malignant lesions and one benign lesion among these. The complication rate in the PET/CT-guided biopsy group was 12.7% (24 of 188), while in the CT-guided group, was 9.5% (14 of 146, p = 0.26). Therefore, there was no significant difference in complication rates between PET/CT and CT guidance. PET/CT-guided biopsy is already known to be a feasible and accurate method in the diagnostic work-up of suspected malignant

  19. Clinical utility of an epigenetic assay to detect occult prostate cancer in histopathologically negative biopsies: results of the MATLOC study.

    Science.gov (United States)

    Stewart, Grant D; Van Neste, Leander; Delvenne, Philippe; Delrée, Paul; Delga, Agnès; McNeill, S Alan; O'Donnell, Marie; Clark, James; Van Criekinge, Wim; Bigley, Joseph; Harrison, David J

    2013-03-01

    Concern about possible false-negative prostate biopsy histopathology findings often leads to rebiopsy. A quantitative methylation specific polymerase chain reaction assay panel, including GSTP1, APC and RASSF1, could increase the sensitivity of detecting cancer over that of pathological review alone, leading to a high negative predictive value and a decrease in unnecessary repeat biopsies. The MATLOC study blindly tested archived prostate biopsy needle core tissue samples of 498 subjects from the United Kingdom and Belgium with histopathologically negative prostate biopsies, followed by positive (cases) or negative (controls) repeat biopsy within 30 months. Clinical performance of the epigenetic marker panel, emphasizing negative predictive value, was assessed and cross-validated. Multivariate logistic regression was used to evaluate all risk factors. The epigenetic assay performed on the first negative biopsies of this retrospective review cohort resulted in a negative predictive value of 90% (95% CI 87-93). In a multivariate model correcting for patient age, prostate specific antigen, digital rectal examination and first biopsy histopathological characteristics the epigenetic assay was a significant independent predictor of patient outcome (OR 3.17, 95% CI 1.81-5.53). A multiplex quantitative methylation specific polymerase chain reaction assay determining the methylation status of GSTP1, APC and RASSF1 was strongly associated with repeat biopsy outcome up to 30 months after initial negative biopsy in men with suspicion of prostate cancer. Adding this epigenetic assay could improve the prostate cancer diagnostic process and decrease unnecessary repeat biopsies. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  20. Retrospective 5-year analysis of MR-guided biopsies in a low-field MR system

    International Nuclear Information System (INIS)

    Zangos, Stephan; Mueller, C.; Mayer, F.; Naguib, N.N.; Nour-Eldin, N.E.A.; Herzog, C.; Hammerstingl, R.M.; Thalhammer, A.; Mack, M.G.; Vogl, T.J.; Eichler, K.; Hansmann, M.L.

    2009-01-01

    Purpose: The purpose of this study was to evaluate the safety and clinical value of MR-guided biopsies in an open 0.2 T low-field system. Materials and methods: A total of 322 patients with suspicious lesions of different body regions were biopsied in a low-field MRI system (0.2 T, Concerto, Siemens). The procedures were guided using T1-weighted Flash sequences (TR/TE = 100/9; 70 ). The lesions were repeatedly biopsied using the coaxial technique with a 15-gauge (diameter 2 mm) puncture needle. Complications and biopsy findings were analyzed retrospectively. Results: In all cases the biopsy procedures were successfully performed with MR guidance. In 298 patients diagnosis was able to be confirmed on the basis of the probes. The clinical follow-up showed that in 24 patients the lesions were missed by MR-guided biopsy. From this a sensitivity of 86%, a specificity of 87% and an accuracy of 93% were calculated. In two patients major complications were observed (morbidity rate 0.6%). Conclusion: MR-guided biopsy can be performed safely and precisely in a low-field MR system and are a supplement to US or CT-guided biopsies. (orig.)

  1. PCA3 and PCA3-Based Nomograms Improve Diagnostic Accuracy in Patients Undergoing First Prostate Biopsy

    Directory of Open Access Journals (Sweden)

    Virginie Vlaeminck-Guillem

    2013-08-01

    Full Text Available While now recognized as an aid to predict repeat prostate biopsy outcome, the urinary PCA3 (prostate cancer gene 3 test has also been recently advocated to predict initial biopsy results. The objective is to evaluate the performance of the PCA3 test in predicting results of initial prostate biopsies and to determine whether its incorporation into specific nomograms reinforces its diagnostic value. A prospective study included 601 consecutive patients addressed for initial prostate biopsy. The PCA3 test was performed before ≥12-core initial prostate biopsy, along with standard risk factor assessment. Diagnostic performance of the PCA3 test was evaluated. The three available nomograms (Hansen’s and Chun’s nomograms, as well as the updated Prostate Cancer Prevention Trial risk calculator; PCPT were applied to the cohort, and their predictive accuracies were assessed in terms of biopsy outcome: the presence of any prostate cancer (PCa and high-grade prostate cancer (HGPCa. The PCA3 score provided significant predictive accuracy. While the PCPT risk calculator appeared less accurate; both Chun’s and Hansen’s nomograms provided good calibration and high net benefit on decision curve analyses. When applying nomogram-derived PCa probability thresholds ≤30%, ≤6% of HGPCa would have been missed, while avoiding up to 48% of unnecessary biopsies. The urinary PCA3 test and PCA3-incorporating nomograms can be considered as reliable tools to aid in the initial biopsy decision.

  2. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  3. 20 CFR 718.106 - Autopsy; biopsy.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Autopsy; biopsy. 718.106 Section 718.106... PNEUMOCONIOSIS Criteria for the Development of Medical Evidence § 718.106 Autopsy; biopsy. (a) A report of an autopsy or biopsy submitted in connection with a claim shall include a detailed gross macroscopic and...

  4. The effect of repeated testing vs repeated practice on skills learning in undergraduate dental education.

    Science.gov (United States)

    Sennhenn-Kirchner, S; Goerlich, Y; Kirchner, B; Notbohm, M; Schiekirka, S; Simmenroth, A; Raupach, T

    2018-02-01

    Recent studies in undergraduate medical education have demonstrated the advantage of repeated testing over repeated practice with regard to knowledge and skills retention. The aim of this study was to investigate whether this "testing effect" also applies to skills retention in undergraduate dental education. In this prospective, randomised controlled trial, fourth-year dental students at Göttingen University Medical Centre participated in a training session on surgical suturing in winter term 2014/2015. Following this, they were either assigned to two sessions of additional skills training (group A) or two sessions of skills assessment with feedback (group B). These sessions were spaced over a period of 4 weeks. Skills retention was assessed in a summative objective structured clinical examination (OSCE) at the end of term, that is 6 months after the initial teaching session. A total of 32 students completed the study. With regard to suturing, OSCE performance was significantly better in group B than group A (81.9±13.1% vs 63.0±15.4%; P=0.001; Cohen's d=1.33). There was no significant OSCE performance difference in the two groups with regard to other learning objectives that were addressed in the end-of-term examination. Thus, the group difference was specific to suturing skills. This is the first study to demonstrate that in dental education, repeated testing produces more favourable skills retention than repeated practice. Test-enhanced learning might be a viable concept for skills retention in undergraduate dentistry education. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Effectiveness of Sedoanalgesia in Percutaneous Liver Biopsy Premedication

    Science.gov (United States)

    Sezgin, Orhan; Ates, Fehmi; Altintas, Engin; Saritas, Bunyamin

    2017-01-01

    Aim: Percutaneous needle liver biopsy (PLB) is frequently associated with pain and anxiety. This may discourage the patients for biopsy, and rebiopsies, if needed. We planned a study to investigate the efficacy of additional analgesia or sedation for PLB. Materials and methods: The study has been designed as a single-center, prospective study. The PLB was planned for 18- to 65-year-old consecutive patients who were included in the study. The patients were divided into three premedication groups as control, Meperidine, and Midazolam. Hospital Anxiety and Depression Scale (HADS) was used to measure each subject’s anxiety level. Fifteen minutes before the biopsy, 1 mL 0.9% NaCl subcutaneously (sc), 1 mg/kg (max 100 mg) Meperidine sc, or 0.1 mg/kg (max 5 mg) Midazolam intravenously was administered to patients respectively. Then PLB was done with 16 G Menghini needle. The day after, the patients were asked about feelings regarding biopsy. Results: Groups were similar by gender and age. The HADS scores prior to PLB and on visual analog scale (VAS, 1-10 points) score during PLB were similar. In the three groups, 7, 12, and 7 patients, respectively, experienced no pain. Other patients explained pain as mild or moderate or severe. The number of patients who agreed for possible rebiopsy was higher in Meperidine and Midazolam groups than in the control group. Conclusion: Premedication with Meperidine or Midazolam in PLB would improve patients’ tolerance, comfort, and attitude against a possible repeat PLB. How to cite this article: Sezgin O, Yaras S, Ates F, Altintas E, Saritas B. Effectiveness of Sedoanalgesia in Percutaneous Liver Biopsy Premedication. Euroasian J Hepato-Gastroenterol 2017;7(2):146-149. PMID:29201797

  6. The effects of hypnotherapy during transrectal ultrasound-guided prostate needle biopsy for pain and anxiety.

    Science.gov (United States)

    Hızlı, Fatih; Özcan, Osman; Selvi, İsmail; Eraslan, Pınar; Köşüş, Aydın; Baş, Okan; Yıkılmaz, Taha Numan; Güven, Oğuz; Başar, Halil

    2015-11-01

    Several studies evaluating the tolerance of transrectal ultrasound (TRUS)-guided needle biopsies showed that moderate-to-severe pain was associated with the procedure. Additionally, prebiopsy anxiety or rebiopsy as a result of a prior biopsy procedure is mentioned as factors predisposing to higher pain intensity. Thus, in this study, we investigated the effects of hypnotherapy during transrectal ultrasound-guided prostate needle biopsy for pain and anxiety. Sixty-four patients presenting for TRUS-guided prostate needle biopsy were randomly assigned to receive either 10-min presurgery hypnosis session (n = 32, mean age 63.5 ± 6.1, p = 0.289) or a presurgery control session (n = 32, mean age 61.8 ± 6.8, p = 0.289). The hypnosis session involved suggestions for increased relaxation and decreased anxiety. Presurgery pain and anxiety were measured using visual analog scales (VAS), Beck Anxiety Inventory (BAI), and Hamilton Anxiety Scale (HAS), respectively. In our statistics, p < 0.05 was considered statistically significant. Postintervention, and before surgery, patients in the hypnosis group had significantly lower mean values for presurgery VAS [mean 1 (0-8); p = 0.011], BAI (6.0 vs 2.0; p < 0.001), and HAS (11.0 vs 6.0; p < 0.001). The study results indicate that a brief presurgery hypnosis intervention can be an effective means of controlling presurgical anxiety, and therefore pain, in patients awaiting diagnostic prostate cancer surgery.

  7. Comparison of sonoelastography guided biopsy with systematic biopsy: impact on prostate cancer detection

    International Nuclear Information System (INIS)

    Pallwein, Leo; Struve, Peter; Aigner, Friedrich; Gradl, Johann; Schurich, Matthias; Frauscher, Ferdinand; Mitterberger, Michael; Horninger, Wolfgang; Bartsch, Georg; Pedross, Florian

    2007-01-01

    A prospective study was performed to determine the value of sonoelastography (SE) targeted biopsy for prostate cancer (PCa) detection. A series of 230 male screening volunteers was examined. Two independent examiners evaluated each subject. One single investigator performed ≤5 SE targeted biopsies into suspicious regions in the peripheral zone only. The stiffness of the lesion was displayed by SE and color-coded from red (soft) to blue (hard). Hard lesions were considered as malignant and targeted by biopsy. Subsequently, another examiner performed ten systematic biopsies. Cancer detection rates of the two techniques were compared. Cancer was detected in 81 of the 230 patients (35%), including 68 (30%) by SE targeted biopsy and in 58 (25%) by systematic biopsy. Cancer was detected by targeted biopsy alone in 23 patients (10%) and by systematic biopsy alone in 13 patients (6%). The detection rate for SE targeted biopsy cores (12.7% or 135 of 1,109 cores) was significantly better than for systematic biopsy cores (5.6% or 130 of 2,300 cores, P < 0.001). SE targeted biopsy in a patient with cancer was 2.9-fold more likely to detect PCa than systematic biopsy. SE targeted biopsy detected more cases of PCa than systematic biopsy, with fewer than half the number of biopsy cores in this prostate-specific antigen screening population. (orig.)

  8. Human Reliability Analysis: session summary

    International Nuclear Information System (INIS)

    Hall, R.E.

    1985-01-01

    The use of Human Reliability Analysis (HRA) to identify and resolve human factors issues has significantly increased over the past two years. Today, utilities, research institutions, consulting firms, and the regulatory agency have found a common application of HRA tools and Probabilistic Risk Assessment (PRA). The ''1985 IEEE Third Conference on Human Factors and Power Plants'' devoted three sessions to the discussion of these applications and a review of the insights so gained. This paper summarizes the three sessions and presents those common conclusions that were discussed during the meeting. The paper concludes that session participants supported the use of an adequately documented ''living PRA'' to address human factors issues in design and procedural changes, regulatory compliance, and training and that the techniques can produce cost effective qualitative results that are complementary to more classical human factors methods

  9. Ultrasound guided core biopsy of suspicious mammographic calcifications using high frequency and power Doppler ultrasound

    International Nuclear Information System (INIS)

    Teh, W.L.; Wilson, A.R.M; Evans, A.J.; Burrell, H.; Pinder, S.E.; Ellis, I.O.

    2000-01-01

    AIM: The pre-operative diagnosis of suspicious mammographic microcalcifications usually requires stereotactic needle biopsy. The aim of this study was to evaluate if high frequency 13 MHz ultrasound (HFUS) and power Doppler (PD) can aid visualization and biopsy of microcalcifications. MATERIALS AND METHODS: Forty-four consecutive patients presenting with microcalcifications without associated mammographic or palpable masses were examined with HFUS and PD. Ultrasound-guided core biopsy (USCB) was performed where possible. Stereotactic biopsy was carried out when US-guided biopsy was unsuccessful. Surgery was performed if a diagnosis of malignancy was made on core biopsy or if the repeat core biopsy was non-diagnostic. RESULTS: Forty-one patients (93%) had ultrasound abnormalities corresponding to mammographic calcification. USCB was performed on 37 patients. In 29/37, USCB obtained a definitive result (78.4%). USCB was non-diagnostic in 4/9 benign (44.4%) and 4/28 (14.3%) malignant lesions biopsied. The complete and absolute sensitivities for malignancy using USCB were 85.7% (24/28) and 81% (23/28), respectively. USCB correctly identified invasive disease in 12/23 (52.2%) cases. There was no significant difference in the presence of abnormal flow on PD between benign and malignant lesions. However, abnormal PD vascularity was present in 43.5% of invasive cancer and was useful in directing successful biopsy in eight cases. CONCLUSION: The combination of high frequency US with PD is useful in the detection and guidance of successful needle biopsy of microcalcifications particularly where there is an invasive focus within larger areas of DCIS. Teh, W.L. (2000)

  10. Sessions and Separability in Security Protocols

    DEFF Research Database (Denmark)

    Carbone, Marco; Guttman, Joshua

    2013-01-01

    Despite much work on sessions and session types in non- adversarial contexts, session-like behavior given an active adversary has not received an adequate definition and proof methods. We provide a syntactic property that guarantees that a protocol has session-respecting executions. Any uncomprom......Despite much work on sessions and session types in non- adversarial contexts, session-like behavior given an active adversary has not received an adequate definition and proof methods. We provide a syntactic property that guarantees that a protocol has session-respecting executions. Any...

  11. Prostate specific antigen velocity does not aid prostate cancer detection in men with prior negative biopsy.

    Science.gov (United States)

    Vickers, Andrew J; Wolters, Tineke; Savage, Caroline J; Cronin, Angel M; O'Brien, M Frank; Roobol, Monique J; Aus, Gunnar; Scardino, Peter T; Hugosson, Jonas; Schröder, Fritz H; Lilja, Hans

    2010-09-01

    Prostate specific antigen velocity has been proposed as a marker to aid in prostate cancer detection. We determined whether prostate specific antigen velocity could predict repeat biopsy results in men with persistently increased prostate specific antigen after initial negative biopsy. We identified 1,837 men who participated in the Göteborg or Rotterdam section of the European Randomized Screening study of Prostate Cancer and who underwent 1 or more subsequent prostate biopsies after an initial negative finding. We evaluated whether prostate specific antigen velocity improved predictive accuracy beyond that of prostate specific antigen alone. Of the 2,579 repeat biopsies 363 (14%) were positive for prostate cancer, of which 44 (1.7%) were high grade (Gleason score 7 or greater). Prostate specific antigen velocity was statistically associated with cancer risk but had low predictive accuracy (AUC 0.55, p <0.001). There was some evidence that prostate specific antigen velocity improved AUC compared to prostate specific antigen for high grade cancer. However, the small increase in risk associated with high prostate specific antigen velocity (from 1.7% to 2.8% as velocity increased from 0 to 1 ng/ml per year) had questionable clinical relevance. Men with prior negative biopsy are at lower risk for prostate cancer at subsequent biopsies with high grade disease particularly rare. We found little evidence to support prostate specific antigen velocity to aid in decisions about repeat biopsy for prostate cancer. 2010 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  12. Fluoroscopy-guided transnasal biopsy of nasopharyngeal carcinoma using a flexible bronchoscopic biopsy forcep

    International Nuclear Information System (INIS)

    Kim, Jai Keun; Chung, Tae Sub; Kim, Dong Ik; Suh, Jung Ho

    1996-01-01

    Otolaryngoscopic biopsy of nasopharyngeal carcinoma is a generalized method which may be associated with inadequate sampling of tissue and patient discomfort. So, we tried fluoroscopy-guided transnasal biopsy using bronchoscopic biopsy forcep and evaluated its safety and efficacy. Prospectively we performed fluoroscopy-guided transnasal biopsy in 11 patients who were radiographically suspected of nasopharyngeal carcinoma. The posterior wall of the nasopharynx was coated with barium sulfate under fluoroscopy. A flexible bronchoscopic biopsy forcep with a steerable guiding catheter which was used in removal of intrahepatic duct stones was inserted through the nare. After localization of the tip of the biopsy forcep at tumor site with fluoroscopy, a tissue specimen was obtained. We also tried CT guided biopsy in initial 2cases. Each patient had otolaryngoscopic biopsy to compare the biopsy result and patient discomfort. We could have sufficient amount of tissue for pathological evaluation in 10 of 11 patients by the first pass with the fluoroscopic technique. Contrarily, otolaryngoscopic biopsy was successful in 7 of 11 patients on single passage. Additionally, 2 patients had complaint in our method comparing with 9 patients in otolaryngoscopic biopsy. Fluoroscopy-guided transnasal biopsy of nasopharyngeal carcinoma using the bronchoscopic biopsy forcep is safe and accurate. It can be a appropriate method competing otolaryngoscopic biopsy

  13. Protocol renal biopsy in patients with lupus nephritis: a single center experience.

    Science.gov (United States)

    Singh, Ametashver; Ghosh, Rabindranath; Kaur, Prabhjeet; Golay, Vishal; Pandey, Rajendra; Roychowdhury, Arpita

    2014-07-01

    Renal biopsy plays an indispensable role in the diagnosis and management of patients with lupus nephritis (LN). A number of studies have evaluated the role of a repeat biopsy in case of disease relapse or treatment unresponsiveness. We studied 40 patients with LN with renal biopsies performed at baseline and after six months of therapy. The baseline and protocol biopsies were compared with respect to histological class transformation, crescents, tubular atrophy, interstitial fibrosis and glomerulosclerosis. We also compared serum creatinine, hemoglobin, systemic lupus erythematosus disease activity index (SLEDAI) scores, 24-h urine protein excretion and C3levels as well as activity index (AI) and chronicity index (CI) at baseline and at six months. Comparison of means was made by paired t test, McNemar test and marginal homogeneity test (multinomial data). Histological class transformation was seen in 10 patients (25%). Intra-class progression to greater chronicity was seen in 10 other patients (25%).There was an increase in glomerulosclerosis, tubular atrophy, interstitial fibrosis and a reduction in cellularity, crescent formation and wire loop lesions in the protocol biopsy. A decline in AI (6.05 vs. 2.50, P protocol biopsy. Our study shows a trend toward greater chronicity in protocol biopsies in LN.

  14. Ultrasound-guided renal biopsy: experience using an automated core biopsy system.

    Science.gov (United States)

    Chan, R; Common, A A; Marcuzzi, D

    2000-04-01

    To assess the safety and efficacy of ultrasound-guided percutaneous renal biopsy using an automated core biopsy system, and to determine radiologists' accuracy in predicting sample adequacy. Ninety-five biopsies were performed on 25 native kidneys and 70 renal allografts using a 16-gauge automated, spring-loaded core biopsy device under real-time sonographic guidance. Radiologists performing the biopsy estimated the number of core samples needed to obtain an adequate specimen, based on visual inspection of each core. The final determination of the number of samples was made by a pathology technologist who attended each biopsy, based on preliminary microscopic examination of tissue cores. After each biopsy, an ultrasonographic examination was performed to search for biopsy-related hemorrhage, and a questionnaire was given to the patient to determine biopsy-related complications, which were categorized as either minor or major. The main indication for biopsy was acute renal failure (in 43.2% of biopsies). An average of 3 tissue cores per biopsy were obtained. Of the 94 patients in whom a biopsy was conducted to exclude diffuse renal disease, a mean of 12.5 glomeruli were present in each specimen. Overall, adequate tissue for diagnosis was obtained in 98.9% of cases. The radiologists' estimate of the number of core samples needed concurred with the pathology technologists' determination of sample adequacy in 88.4% of cases. A total of 26 complications occurred (in 27.4% of biopsies), consisting of 23 minor (24.2%) and 3 major (3.2%) complications. Real-time sonographic guidance in conjunction with an automated core biopsy system is a safe and accurate method of performing percutaneous renal biopsy. Routine use of sonographic examinations to search for biopsy-related complications is not indicated. Radiologists are accurate in estimating sample adequacy in most cases; however, the presence of a pathology technologist at the biopsy procedure virtually eliminates the

  15. Revisiting the TALE repeat.

    Science.gov (United States)

    Deng, Dong; Yan, Chuangye; Wu, Jianping; Pan, Xiaojing; Yan, Nieng

    2014-04-01

    Transcription activator-like (TAL) effectors specifically bind to double stranded (ds) DNA through a central domain of tandem repeats. Each TAL effector (TALE) repeat comprises 33-35 amino acids and recognizes one specific DNA base through a highly variable residue at a fixed position in the repeat. Structural studies have revealed the molecular basis of DNA recognition by TALE repeats. Examination of the overall structure reveals that the basic building block of TALE protein, namely a helical hairpin, is one-helix shifted from the previously defined TALE motif. Here we wish to suggest a structure-based re-demarcation of the TALE repeat which starts with the residues that bind to the DNA backbone phosphate and concludes with the base-recognition hyper-variable residue. This new numbering system is consistent with the α-solenoid superfamily to which TALE belongs, and reflects the structural integrity of TAL effectors. In addition, it confers integral number of TALE repeats that matches the number of bound DNA bases. We then present fifteen crystal structures of engineered dHax3 variants in complex with target DNA molecules, which elucidate the structural basis for the recognition of bases adenine (A) and guanine (G) by reported or uncharacterized TALE codes. Finally, we analyzed the sequence-structure correlation of the amino acid residues within a TALE repeat. The structural analyses reported here may advance the mechanistic understanding of TALE proteins and facilitate the design of TALEN with improved affinity and specificity.

  16. Reconfigurable multiport EPON repeater

    Science.gov (United States)

    Oishi, Masayuki; Inohara, Ryo; Agata, Akira; Horiuchi, Yukio

    2009-11-01

    An extended reach EPON repeater is one of the solutions to effectively expand FTTH service areas. In this paper, we propose a reconfigurable multi-port EPON repeater for effective accommodation of multiple ODNs with a single OLT line card. The proposed repeater, which has multi-ports in both OLT and ODN sides, consists of TRs, BTRs with the CDR function and a reconfigurable electrical matrix switch, can accommodate multiple ODNs to a single OLT line card by controlling the connection of the matrix switch. Although conventional EPON repeaters require full OLT line cards to accommodate subscribers from the initial installation stage, the proposed repeater can dramatically reduce the number of required line cards especially when the number of subscribers is less than a half of the maximum registerable users per OLT. Numerical calculation results show that the extended reach EPON system with the proposed EPON repeater can save 17.5% of the initial installation cost compared with a conventional repeater, and can be less expensive than conventional systems up to the maximum subscribers especially when the percentage of ODNs in lightly-populated areas is higher.

  17. CT-Guided Transgluteal Biopsy for Systematic Random Sampling of the Prostate in Patients Without Rectal Access.

    Science.gov (United States)

    Goenka, Ajit H; Remer, Erick M; Veniero, Joseph C; Thupili, Chakradhar R; Klein, Eric A

    2015-09-01

    The objective of our study was to review our experience with CT-guided transgluteal prostate biopsy in patients without rectal access. Twenty-one CT-guided transgluteal prostate biopsy procedures were performed in 16 men (mean age, 68 years; age range, 60-78 years) who were under conscious sedation. The mean prostate-specific antigen (PSA) value was 11.4 ng/mL (range, 2.3-39.4 ng/mL). Six had seven prior unsuccessful transperineal or transurethral biopsies. Biopsy results, complications, sedation time, and radiation dose were recorded. The mean PSA values and number of core specimens were compared between patients with malignant results and patients with nonmalignant results using the Student t test. The average procedural sedation time was 50.6 minutes (range, 15-90 minutes) (n = 20), and the mean effective radiation dose was 8.2 mSv (median, 6.6 mSv; range 3.6-19.3 mSv) (n = 13). Twenty of the 21 (95%) procedures were technically successful. The only complication was a single episode of gross hematuria and penile pain in one patient, which resolved spontaneously. Of 20 successful biopsies, 8 (40%) yielded adenocarcinoma (Gleason score: mean, 8; range, 7-9). Twelve biopsies yielded nonmalignant results (60%): high-grade prostatic intraepithelial neoplasia (n = 3) or benign prostatic tissue with or without inflammation (n = 9). Three patients had carcinoma diagnosed on subsequent biopsies (second biopsy, n = 2 patients; third biopsy, n = 1 patient). A malignant biopsy result was not significantly associated with the number of core specimens (p = 0.3) or the mean PSA value (p = 0.1). CT-guided transgluteal prostate biopsy is a safe and reliable technique for the systematic random sampling of the prostate in patients without a rectal access. In patients with initial negative biopsy results, repeat biopsy should be considered if there is a persistent rise in the PSA value.

  18. 'Microerosions' in rectal biopsies in Crohn's disease

    DEFF Research Database (Denmark)

    Poulsen, Steen Seier

    1984-01-01

    Small (less than 1 mm), superficial erosions ('microerosions') have been observed stereo-microscopically in surface-stained rectal biopsies in Crohn's disease (CD). Biopsy specimens from 97 patients with CD, 225 with ulcerative colitis (UC), and a control material of 161 patients were investigated....... Granulomas were identified in 62% of the biopsies with microerosions and by examination of two consecutive biopsies from each of these patients, in 85% indicating a positive correlation. In patients with microerosions and a primary diagnosis of UC, granulomas were found in 38% and by examination of two...... biopsies in 54%. Patients with granulomas and a few other patients were reclassified as CD, but there still remained some patients with microerosions, who most probably had UC. In conclusion, microerosions are observed mainly in CD with colonic involvement. There is a high incidence of granulomas in biopsy...

  19. Quantum repeated games revisited

    International Nuclear Information System (INIS)

    Frąckiewicz, Piotr

    2012-01-01

    We present a scheme for playing quantum repeated 2 × 2 games based on Marinatto and Weber’s approach to quantum games. As a potential application, we study the twice repeated Prisoner’s Dilemma game. We show that results not available in the classical game can be obtained when the game is played in the quantum way. Before we present our idea, we comment on the previous scheme of playing quantum repeated games proposed by Iqbal and Toor. We point out the drawbacks that make their results unacceptable. (paper)

  20. Postradiotherapy prostate biopsies: what do they really mean? results for 498 patients

    International Nuclear Information System (INIS)

    Crook, Juanita; Malone, Shawn; Perry, Gad; Bahadur, Yasir; Robertson, Susan; Abdolell, Mohamed

    2000-01-01

    Purpose: Postradiotherapy (RT) prostate biopsies are prone to problems in interpretation. False negatives due to sampling error, false positives due to delayed tumor regression, and indeterminate biopsies showing radiation effect in residual tumor of uncertain viability are common occurrences. Methods and Materials: A cohort of 498 men treated with conventional RT from 06/87-10/96 were followed prospectively with systematic transrectal ultrasound (TRUS)-guided post-RT prostate biopsies, starting 12-18 months after RT. If there was residual tumor but further decline in serum prostate-specific antigen (PSA), biopsies were repeated every 6-12 months. Patients with negative biopsies were rebiopsied at 36 months. Residual tumor was evaluated for RT effect and proliferation markers. The 498 men had 978 biopsies. Median time of the first biopsy (n = 498) was 13 months, biopsy no. 2 (n = 342) 28 months, biopsy no. 3 (n = 110) 36 months, biopsy no. 4 (n = 28) 44 months, and biopsy no. 5 (n = 4) 55 months. Median follow-up is 54 months (range 13-131). One hundred seventy-five patients (34%) had prior hormonal therapy for a median of 5 months (range 1-60). Results: Clinical stage distribution was T1b: 46; T1c: 50; T2a: 115; T2b/c: 170; T3: 108; T4: 11; Tx: 1. Distribution by Gleason score was: 28% Gleason score 2-4; 42%: 5-6; 18%: 7; and 12%: 8-10. Seventy-one men have died, 26 of prostate cancer and 45 of other causes. Actuarial failure-free survival by T stage at 5 years is T1b: 78%; T1c: 76%; T2a: 60%; T2b/c: 55%; T3: 30%; and T4: 0%. Actuarial freedom from local failure at 5 years is T1b: 83%; T1c: 88%; T2a: 72%; T2b/c: 66%; T3: 58%; and T4: 0%. The proportion of indeterminate biopsies decreases with time, being 33% for biopsy 1, 24% for biopsy 2, 18% for biopsy 3, and 7% for biopsy 4. Thirty percent of indeterminate biopsies resolved to NED status, regardless of the degree of RT effect, 18% progressed to local failure, and 34% remained as biopsy failures with

  1. Nerve Biopsy In The Diagnosis Of Leporsy

    OpenAIRE

    Hazra B; Banerjee P P; Bhattacharyya N K; Gupta P N; Barbhunia J N; Sanyal S

    1997-01-01

    Skin and nerve biopsies were done in 33 cases of different clinical types of leprosy selected from Dermatology OPD of Medical College and Hospitals, Calcutta during 1994-95. Histopathological results were compared with emphasis on the role of nerve biopsies in detection of patients with multibacillary leprosy. The evident possibility of having patients with multibacillary leprosy in peripheral leprosy with multiple drugs. It is found that skin and nerve biopsy are equally informative in borde...

  2. Infective endocarditis with spondylodiscitis after prostate biopsy

    Directory of Open Access Journals (Sweden)

    Fernando Pivatto Júnior

    2014-04-01

    Full Text Available Transrectal ultrasonography-guided prostate needle biopsy is the ideal method to obtain prostate specimens for histological analysis and is therefore frequently used in clinical practice. In the majority of the studies, prostate biopsy is considered a safe procedure with few major complications. In the present report, we describe a case of endocarditis with spondylodiscitis, two very rare complications of prostate biopsy.

  3. Nerve Biopsy In The Diagnosis Of Leporsy

    Directory of Open Access Journals (Sweden)

    Hazra B

    1997-01-01

    Full Text Available Skin and nerve biopsies were done in 33 cases of different clinical types of leprosy selected from Dermatology OPD of Medical College and Hospitals, Calcutta during 1994-95. Histopathological results were compared with emphasis on the role of nerve biopsies in detection of patients with multibacillary leprosy. The evident possibility of having patients with multibacillary leprosy in peripheral leprosy with multiple drugs. It is found that skin and nerve biopsy are equally informative in borderline and lepromatour leprosy and is the only means to diagnose polyneuritic leprosy. Nerve biopsy appears to be more informative in the diagnosis of all clinical types of leprosy.

  4. Surface staining of small intestinal biopsies

    DEFF Research Database (Denmark)

    Poulsen, Steen Seier

    1977-01-01

    Small intestinal biopsies are most often by routine examined under a stereo-microscope, prior to embedding for histological examination. This is done in order to get a view of the appearance of the mucosal pattern, especially villus configuration. The distinctness of the surface pattern however......, is improved considerably if the biopsies are stained with Alcian Green and/or PAS before they are examined. In the present paper a detailed description is given of staining of small intestinal biopsies as whole mounts. The difference between the unstained and the stained biopsies is illustrated by a few...

  5. Robotic Prostate Biopsy in Closed MRI Scanner

    National Research Council Canada - National Science Library

    Fischer, Gregory

    2008-01-01

    .... This work enables prostate brachytherapy and biopsy procedures in standard high-field diagnostic MRI scanners through the development of a robotic needle placement device specifically designed...

  6. Needle muscle biopsy and its application

    Directory of Open Access Journals (Sweden)

    Meng-long CHEN

    2015-07-01

    Full Text Available Needle muscle biopsy is a straightforward and reliable minimally-invasive technique. During the past century, the needle biopsy can provide adequate samples and the technique has gradually gained wider acceptance. Compared with open biopsy, needle biopsy is less traumatic, with low rate of complications, and is suitable for the identifications and evaluations of muscular dystrophy, inflammatory myopathies and systemic diseases involving muscles, specially for infants and young children. Domestic insiders should be encouraged to apply this technique. DOI: 10.3969/j.issn.1672-6731.2015.06.003 

  7. Punch Biopsy Results in Misdiagnosis of Pilomatrixoma

    Directory of Open Access Journals (Sweden)

    Metin Temel

    2017-03-01

    Full Text Available Punch biopsy results in misdiagnosis of clinically unsuspected giant pilomatrixoma located over the parotid gland. This study presents a case of pilomatrixoma that was misdiagnosed as a malignant epithelial tumor using punch biopsy. A 25-year-old male was admitted to our clinic for the evaluation of a mass measuring 7×8×8 cm located over the parotid gland. The patient had previously undergone punch biopsy at another clinic because of a lesion in the parotid gland. Punch biopsy revealed a malignant epithelial tumor. The patient underwent excisional biopsy at our clinic. After the biopsy, the residual skin defect was treated using full-thickness skin grafts. The facial nerve and parotid gland were preserved during the biopsy. Histopathological examination of the excisional biopsy material revealed pilomatrixoma. Punch biopsy may result in misdiagnosis of skin lesions in the parotid gland. A differential diagnosis for benign tumors such as pilomatrixoma is essential prior to an aggressive surgical intervention of the parotid gland.

  8. Adult dementia: history, biopsy, pathology.

    Science.gov (United States)

    Torack, R M

    1979-05-01

    The historical events in the evolution of Alzheimer's disease are reviewed, including the initial description by Alois Alzheimer and the subsequent controversy regarding the nosological specificity of this entity. The similarity of senile dementia and Alzheimer's disease is emphasized. The basis for the modern concept of Alzheimer's disease as premature or accelerated aging is included in the review. The pathological correlates of the major categories of adult dementia have been described. The traditional criteria of neurofibrillary tangles and senile plaques have been re-evaluated using the current insight into these changes afforded by electron microscopy and biochemistry. The significance of amyloid has been described because it occurs within the senile plaque and also as the essential component of congophilic angiopathy. The new information regarding neuronal cell counts and the loss of choline acetyltransferase has been evaluated in terms of an indication of a pathogenic mechanism of Alzheimer's disease. The current understanding of normal pressure hydrocephalus, Creutzfeldt-Jakob disease, and multi-infarct dementia has been described. Brain biopsy in dementia has been described as having diagnostic, research, pathogenic, and prognostic value. The precautions involving the performance and handling of the biopsy have been stressed, particularly because these procedures involve conditions of possible slow virus etiology. The polemic for Alzheimer's disease as aging or slow virus infection has been summarized. At this time a consideration seems justified that Alzheimer's disease is an age-related, slow virus disease due to a hitherto unknown immune defect. Aging as an etiological agent must be clarified before Alzheimer's disease, in any form, can be considered to be an inevitable consequence of longevity.

  9. Electronomicroscopic evaluation of the microlesional aspects in the pulp dentinal complex after repeated whitening therapy

    Science.gov (United States)

    Bodea, Rodica; Jianu, Rodica; Marchese, Cristian; Vasile, Liliana

    2012-06-01

    The aim of this study was to examine cellular and matriceal dynamics within pulp tissue of the teeth with repeated bleaching. Material and method - The study was made on 25 patients aged between 15 and 45, to whom bleaching method of the premolars with indication of extraction in orthodontic purposes was applied. None of the subjects smoked and throughout the investigation no antibiotics had been used. We initiated an intensive oral hygiene program, and we removed the supragingival and subgingival deposits. Oral hygiene and the gingival health were evaluated before every session of bleaching. During each visit the dentition was cleaned professionally and if needed the subjects were reinstucted in proper oral hygiene. After 3 and 5 successive bleachings of the teeth, we removed the dental pulps and we extracted the premolars. The pulpal biopsies were fixed in buffed formaldehyde 10% for 48 hours, then paraffinized, sectioned at 3-5 μ and stained with topographic, H&E and trichrome stained. For the electonomicroscopic study we used the Lehner technique to process the biopsies (n=3) after the reinclusion of the pieces from the paraffine blocks in Epon, postfixated in buffered glutaraldehyde, micro sectioned at 0,5 μ, contrastated with Pb citrate (stained) and examination in transmission electronic microscopy with Philips microscope. Results - At cellular and matriceal level we observed a marked collagen fibrillogenesis in the presence of active fibroblasts, with well developed cellular organites and fibroclastic aspects which suggest matriceal active repair. The microvascular network presents an activated endothelium with turgescent endothelial cells, with intracitoplasmatic resorbtion vacuols, well developed Golgi Complex. Conclusion - We interpreed the cell - matriceal lesions in the context of the acute inflammatory process in the first lesional phase and chronic scleroatrophic process after successive bleaching.

  10. Clinical outcome following a low-suspicion multiparametric prostate MRI or benign MRI-guided biopsy to detect prostate cancer

    DEFF Research Database (Denmark)

    Boesen, Lars; Nørgaard, Nis; Løgager, Vibeke

    2017-01-01

    follow-up [132/156 (85%)] had decreasing levels of prostate-specific-antigen and could be monitored in primary care. CONCLUSION: A low-suspicion MRI in men with prior negative systematic biopsies has a high negative predictive value in ruling out longer term significant cancer. Therefore, immediate...... repeated biopsies are of limited clinical value and could be avoided even if prostate-specific-antigen levels are persistently elevated.......PURPOSE: To assess the future risk of detecting significant prostate cancer following either a low-suspicion MRI or suspicious MRI with benign MRI-guided biopsies in men with prior negative systematic biopsies. MATERIALS AND METHODS: 289 prospectively enrolled men underwent MRI followed by repeated...

  11. The effect of repeated applanation on subsequent IOP measurements.

    Science.gov (United States)

    AlMubrad, Turki M; Ogbuehi, Kelechi C

    2008-11-01

    In studies aimed at assessing the accuracy and repeatability of non-contact tonometers, the order in which these tonometers and the Goldmann tonometer are used is usually randomised despite studies in the literature that demonstrate an ocular massage effect that occurs post-applanation but not after non-contact tonometry. The purpose of this study was to investigate the effect of repeated corneal applanation on subsequent assessments of IOP. Data were obtained from 65 left eyes of 65 young, oculovisual normals. Three sets of IOP measurements were obtained, one set with the Goldmann applanation tonometer and two with the Topcon CT80 non-contact tonometer (one set each before and after applanation with the Goldmann tonometer), in each one of two separate measurement sessions, one week apart. The average (and SD) IOP measured with the Goldmann tonometer in the first session (14.8+/-2.9 mmHg) did not vary significantly from the IOP measured with the non-contact tonometer (pre-applanation) in both sessions or with the average Goldmann IOP in the second session. The bias (mean difference +/- SD) between methods was 0.3+/-1.4 mmHg and 0.4+/-1.4 mmHg, respectively, for the first and second sessions, with the CT80 (pre-applanation) recording the higher IOP in both sessions. The within-session repeatability coefficients were +/-2.3 mmHg, +/-2.6 mmHg, +/-2.1 mmHg and +/-2.0 mmHg for the CT80 (pre-applanation) in the first and second sessions, and the Goldmann tonometer in the first and second sessions, respectively. Test-retest repeatability coefficients were +/-2.8 mmHg and +/-2.5 mmHg for the CT80 (pre-applanation) and the Goldmann tonometer respectively. Post-applanation with the Goldmann tonometer, there was a statistically significant (pcontact tonometer in both sessions. These results suggest that repeated corneal applanation leads to a statistically significant reduction in IOP on subsequent measurements.

  12. Repeat migration and disappointment.

    Science.gov (United States)

    Grant, E K; Vanderkamp, J

    1986-01-01

    This article investigates the determinants of repeat migration among the 44 regions of Canada, using information from a large micro-database which spans the period 1968 to 1971. The explanation of repeat migration probabilities is a difficult task, and this attempt is only partly successful. May of the explanatory variables are not significant, and the overall explanatory power of the equations is not high. In the area of personal characteristics, the variables related to age, sex, and marital status are generally significant and with expected signs. The distance variable has a strongly positive effect on onward move probabilities. Variables related to prior migration experience have an important impact that differs between return and onward probabilities. In particular, the occurrence of prior moves has a striking effect on the probability of onward migration. The variable representing disappointment, or relative success of the initial move, plays a significant role in explaining repeat migration probabilities. The disappointment variable represents the ratio of actural versus expected wage income in the year after the initial move, and its effect on both repeat migration probabilities is always negative and almost always highly significant. The repeat probabilities diminish after a year's stay in the destination region, but disappointment in the most recent year still has a bearing on the delayed repeat probabilities. While the quantitative impact of the disappointment variable is not large, it is difficult to draw comparisons since similar estimates are not available elsewhere.

  13. Topical Session on Materials Management

    International Nuclear Information System (INIS)

    2002-01-01

    At its second meeting, in Paris, 5-7 December 2001, the WPDD held two topical sessions on the D and D Safety Case and on the Management of Materials from D and D, respectively. This report documents the topical session on the management of materials. Presentations during the topical session covered key aspects of the management of materials and meant to provide an exchange of information and experience, including: Experience and lessons learnt from VLLW and non-radioactive material management in Spain and Germany with special attention to recycling (How specific solutions came about? Are there 'generic' examples for wider adoption?); Risk assessment of recycling and non-recycling: a CPD study; Waste acceptance issues within different national contexts (What constraints are there on the waste receiving body and what flexibility can the latter have? What constraints does this impose on D and D implementers? What about wastes are without current solution? What needs to be done? What about large items and 'difficult' waste in general?); Radiological characterisation of materials during decommissioning, particularly difficult situations - large volumes, large items,.. wastes, heterogeneous streams (What examples of established practice? What are the approaches or aspects that set the regulatory requirements? How can the flow rates be large but the answers acceptable? How much is needed to be known for later action, e. g., disposal, release, protection of worker, etc.); Radiological characterisation of buildings as they stand, in order to allow conventional demolition (What are strategies for optimisation of characterisation? How much needs to be known to take action later? e.g. for storage, disposal, release, cost estimation and ALARA? What needs to be done in advance and after decommissioning/dismantling?). At the end of each presentation time was allotted for discussion of the paper. Integral to the Topical Session was a facilitated plenary discussion on the topical

  14. [Muscle biopsy in children: Usefulness in 2012].

    Science.gov (United States)

    Cuisset, J-M; Maurage, C-A; Carpentier, A; Briand, G; Thévenon, A; Rouaix, N; Vallée, L

    2013-01-01

    Muscle biopsy is a mainstay diagnostic tool for investigating neuromuscular disorders in children. We report the yield of pediatric muscle biopsy in a population of 415 children by a retrospective study of 419 biopsies performed between 1/01/2000 and 31/12/2009 in a neuropediatric department, including mitochondrial respiratory chain analysis for 87 children. Two hundred and fifty-five biopsies were from boys (61%) 164 from girls (39%). Their mean age at biopsy was 6.5years; 155 (37%) biopsies were obtained before the child was 5years old. Final histopathological diagnoses were: congenital myopathy (n=193, including 15 structural congenital myopathies); progressive muscular dystrophy (n=75 [18%] including 57 dystrophinopathies); congenital muscular dystrophy (n=17, including six primary merosinopathies); dermatomyositis (n=11); spinal muscular atrophy (n=9, including six atypical spinal muscular atrophies); metabolic myopathy (n=32, including 19 mitochondrial myopathies); encephalomyopathy (n=53 [13%], including 27 with a mitochondrial respiratory chain defect). Pathological diagnosis remained undetermined in 16 cases. In 184 patients (44%), the muscle biopsy revealed specific histopathological anomalies (dystrophic process; specific ultrastructural abnormalities; perifascicular atrophy; neurogenic atrophy; metabolic anomalies) enabling a precise etiological diagnosis. For 85% of progressive muscular dystrophies, the biopsy resulted in a genetic diagnosis after identification of the protein defect. In 15% of the congenital myopathies, histopathological anomalies focused attention on one or several genes. Concerning dystrophinopathies, quantification of dystrophin deficiency on the biopsy specimen contributed to the definition of the clinical phenotype: Duchenne, or Becker. In children with a myopathy, muscle biopsy is often indispensable to establish the etiological diagnosis. Based on the results from this series, muscle biopsy can provide a precise

  15. Beam instability Workshop - plenary sessions

    International Nuclear Information System (INIS)

    2001-01-01

    The purpose of this workshop was to provide a review of the mechanisms of limiting beam instabilities, their cures, including feedback, and beam measurement for synchrotron radiation light sources. 12 plenary sessions took place whose titles are: 1) challenging brilliance and lifetime issues with increasing currents; 2) limiting instabilities in multibunch; 3) experience from high currents in B factories; 4) longitudinal dynamics in high intensity/bunch; 5) Transverse instabilities for high intensity/bunch; 6) working group introduction from ESRF experience; 7) impedance modelling: simulations, minimization; 8) report on the broadband impedance measurements and modelling workshop; 9) feedback systems for synchrotron light sources; 10) beam instabilities diagnostics; 11) harmonic cavities: the pros and cons; and 12) experimental study of fast beam-ion instabilities at PLS. This document gathers the 12 articles that were presented during these sessions

  16. Beam instability Workshop - plenary sessions

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    The purpose of this workshop was to provide a review of the mechanisms of limiting beam instabilities, their cures, including feedback, and beam measurement for synchrotron radiation light sources. 12 plenary sessions took place whose titles are: 1) challenging brilliance and lifetime issues with increasing currents; 2) limiting instabilities in multibunch; 3) experience from high currents in B factories; 4) longitudinal dynamics in high intensity/bunch; 5) Transverse instabilities for high intensity/bunch; 6) working group introduction from ESRF experience; 7) impedance modelling: simulations, minimization; 8) report on the broadband impedance measurements and modelling workshop; 9) feedback systems for synchrotron light sources; 10) beam instabilities diagnostics; 11) harmonic cavities: the pros and cons; and 12) experimental study of fast beam-ion instabilities at PLS. This document gathers the 12 articles that were presented during these sessions.

  17. National Sessions of Radiation Protection

    International Nuclear Information System (INIS)

    Sociedad Argentina de Radioproteccion

    2012-01-01

    The Radioprotection Argentine Society (SAR) was organized the National Sessions on Radiation Protection 2012 in order to continue the exchange in the radiation protection community in the country, on work areas that present a challenge to the profession. The new recommendations of the ICRP and the IAEA Safety Standards (2011), among others, includes several topics that are necessary to develop. The SAR wants to encourage different organizations from Argentina, to submit projects that are developing in order to strengthen radiation protection.

  18. Scientific conference proceedings. Session 3

    International Nuclear Information System (INIS)

    Bartosek, V.

    1985-01-01

    The Radiochemical Technology session met at UJV Rez on June 7, 1985 to hear 13 papers of which 11 were incorporated in INIS. The papers inform of results attained in the field of processing liquid radioactive wastes from nuclear power plants, processing spent nuclear fuel using the fluoride process, of the separation of fission products by dicarbolide extraction, the chemistry of complex uranium compounds, etc. The cooperation of UJV with VUJE and VUCHZ is also dealt with. (E.S.)

  19. Prostate biopsy after ano-rectal resection: value of CT-guided trans-gluteal biopsy

    International Nuclear Information System (INIS)

    Cantwell, Colin P.; Hahn, Peter F.; Gervais, Debra A.; Mueller, Peter R.

    2008-01-01

    We describe our single-institutional experience with computed tomography (CT)-guided percutaneous transgluteal biopsy of the prostate in patients in whom transrectal ultrasound-guided biopsy is precluded by prior ano-rectal resection. Between March 1995 and April 2007, 22 patients had 34 prostate biopsies (mean age 68; mean PSA 29 ng/ml; mean follow-up 6.1 years). The charts of patients who had transgluteal biopsy were reviewed for demographic, complications and pathology. Ninety-five percent (21/22) of primary biopsies were diagnostic. Of the 21 diagnostic biopsies, 11 were positive for prostate cancer and ten were definitive benign samples. Seventy-three percent (8/11) of the patients had progressive PSA elevation that mandated 11 further prostate biopsies. Six patients had a second biopsy, one patient had a third and one patient had a fourth biopsy. Among patients who had serial biopsies, 38% (3/8) had prostate cancer. No complications or death occurred. A malignant biopsy was not significantly associated with core number (P = 0.58) or a high PSA level (P 0.15). CT-guided transgluteal biopsy of the prostate is safe and effective. (orig.)

  20. Comparison between endobronchial forceps-biopsy and cryo-biopsy by flexible

    Directory of Open Access Journals (Sweden)

    Sami El-Dahdouh

    2016-01-01

    Conclusions: We concluded that cryoprobe biopsies were more successful than forceps biopsies in the diagnosis of lung cancer. Nevertheless, further investigations are warranted to determine an efficacy of cryoprobe biopsy procedures and a rationale to use as a part of routine flexible bronchoscopy.

  1. Where Do Transrectal Ultrasound- and Magnetic Resonance Imaging-guided Biopsies Miss Significant Prostate Cancer?

    DEFF Research Database (Denmark)

    Boesen, Lars; Nørgaard, Nis; Løgager, Vibeke

    2017-01-01

    -guided biopsy (reTRUSbx) and targeted mpMRIbx (image fusion) of any suspicious lesion. Biopsy results were compared and the locations of missed sPCa lesions were registered. Cancer significance was defined as (1) any core with a Gleason score of >6, (2) cancer core involvement of ≥50% and for re......TRUSbx on patient level, and (3) the presence of ≥3 positive cores. RESULTS: Of the 289 patients, prostate cancer was detected in 128 (44%) with 88 (30%) having sPCa. Overall, 165 separate prostate cancer lesions were detected with 100 being sPCa. Of these, mpMRIbx and reTRUSbx detected 90% (90/100) and 68% (68...... TRUSbx and mpMRIbx missed sPCa lesions in specific segments of the prostate. Missed sPCa lesions at repeat biopsy were primarily located anteriorly for TRUSbx and posterolateral midprostatic for mpMRIbx. Localization of these segments may improve biopsy techniques in men undergoing repeat biopsies....

  2. Ultrasound guided synovial biopsy of the wrist

    NARCIS (Netherlands)

    van Vugt, R. M.; van Dalen, A.; Bijlsma, J. W.

    1997-01-01

    Seven patients (4 female and 3 male, mean age 46) with arthritis of the wrist (n = 7) without known etiology were evaluated. High-definition ultrasound equipment was used for localization of synovial hypertrophy, suitable for ultrasound guided biopsy without risk. A 18-gauge diameter Tru-cut biopsy

  3. Stereotactic core biopsy of an impalpable screen-detected breast lesion using acupuncture-analgesia

    OpenAIRE

    English, R E; Chen, J H

    2010-01-01

    Chinese acupuncture-analgesia is used for pain management during various surgical procedures. Over the past 40 years this approach has been introduced in many countries and has been particularly helpful in the investigation and treatment of patients who are unable to tolerate conventional analgesia. We report here the case of a woman with a 17-year history of myalgic encephalitis who underwent a stereotactic core biopsy of the breast under acupuncture-analgesia. A planning session was needed ...

  4. Histopathologic quality of prostate core biopsy specimens: comparison of an MR-compatible biopsy needle and a ferromagnetic biopsy needle used for ultrasound-guided prostate biopsy

    International Nuclear Information System (INIS)

    Franiel, T.; Hamm, B.; Beyersdorff, D.; Fritzsche, F.; Staack, A.; Rost, J.

    2006-01-01

    Purpose: The histopathologic quality of core biopsy specimens obtained via MRI-guided prostate biopsy using a 16G MR-compatible needle was compared to that of biopsies obtained via ultrasound-guided biopsy using a conventional 18G stainless steel biopsy needle. Material and Methods: A retrospective analysis was performed for a total of 247 transrectal prostate biopsy specimens obtained from 32 patients. A total of 117 tissue cores were obtained from 15 patients (PSA of 10.8 ng/ml, age 64 years) who underwent an MRI-guided prostate biopsy using a 16G (1.7 mm) MR-compatible biopsy needle made of titanium alloy. The remaining 130 tissue cores were obtained from 17 patients (PSA of 6.7 ng/ml, age 68 years) who underwent a transrectal ultrasound-guided prostate biopsy using an 18G (1.3 mm) ferromagnetic stainless steel biopsy needle. The length and width of the histologic sections prepared from the tissue cores were measured to calculate the area. The histopathologic quality of the specimens was assessed microscopically using tissue fragmentation, the presence of crush artifacts, and the overall assessability as criteria. Each of these features was assigned a score from 0 to 3. All 3 features contributed equally to the overall score which ranged from 0 (no tissue) to 9 (optimal quality). Results: The overall quality scores assigned to the biopsies obtained with a 16G MR-compatible needle and an 18G ferromagnetic needle can be considered to be equivalent to a mean difference between patient related median scores of the specimens of -0.05 (95% confidence interval [-0.46; 0.36]) and a given equivalence limit of 1. The MRI biopsies showed more tissue fragmentation (p=0.001) but fewer crush artifacts (p=0.022) while the assessability did not differ significantly between the two needle types (p=0.064). There was also no significant difference in the calculated areas of the tissue cores (p=0.236). According to the different calibers of the biopsy needles, the lengths (p=0

  5. Coeliac disease: to biopsy or not?

    Science.gov (United States)

    Reilly, Norelle R; Husby, Steffen; Sanders, David S; Green, Peter H R

    2018-01-01

    Coeliac disease is increasingly recognized as a global problem in both children and adults. Traditionally, the findings of characteristic changes of villous atrophy and increased intraepithelial lymphocytosis identified in duodenal biopsy samples taken during upper gastrointestinal endoscopy have been required for diagnosis. Although biopsies remain advised as necessary for the diagnosis of coeliac disease in adults, European guidelines for children provide a biopsy-sparing diagnostic pathway. This approach has been enabled by the high specificity and sensitivity of serological testing. However, these guidelines are not universally accepted. In this Perspective, we discuss the pros and cons of a biopsy-avoiding pathway for the diagnosis of coeliac disease, especially in this current era of the call for more biopsies, even from the duodenal bulb, in the diagnosis of coeliac disease. In addition, a contrast between paediatric and adult guidelines is presented.

  6. Repeated Recall and PKM? Maintain Fear Memories in Juvenile Rats

    Science.gov (United States)

    Oliver, Chicora F.; Kabitzke, Patricia; Serrano, Peter; Egan, Laura J.; Barr, Gordon A.; Shair, Harry N.; Wiedenmayer, Christoph

    2016-01-01

    We examined the neural substrates of fear memory formation and maintenance when repeated recall was used to prevent forgetting in young animals. In contrast to adult rats, juveniles failed to show contextual fear responses at 4 d post-fear conditioning. Reconsolidation sessions 3 and 6 d after conditioning restored contextual fear responses in…

  7. Usefulness of CT fluoroscopy-guided percutaneous needle biopsy in the presence of pneumothorax during biopsy

    International Nuclear Information System (INIS)

    O, Dong Hyun; Cho, Young Jun; Park, Yong Sung; Hwang, Cheol Mok; Kim, Keum Won; Kim, Ji Hyung

    2006-01-01

    When pneumothorax occurs during a percutaneous needle biopsy, the radiologist usually stops the biopsy. We evaluated the usefulness of computed tomographic (CT) fluoroscopy-guided percutaneous needle biopsy in the presence of pneumothorax during biopsy. We performed 288 CT fluoroscopy guided percutaneous needle biopsies to diagnose the pulmonary nodules. Twenty two of these patients had pneumothorax that occurred during the biopsy without obtaining an adequate specimen. After pneumothorax occurred, we performed immediate CT fluoroscopy guided percutaneous needle biopsies using an 18-gauge cutting needle. We evaluated the success rate of the biopsies and also whether or not the pneumothorax progressed. We classified these patients into two groups according to whether the pneumothorax progressed (Group 2) or not (Group 1) by measuring the longest distance between the parietal pleura and the visceral pleura both in the early and late pneumothorax. Additionally, we analyzed the relationship between the progression of pneumothorax after biopsy and 1) the depth of the pulmonary nodule; 2) the number of biopsies; 3) the presence or absence of emphysema at the biopsy site; and 4) the size of the pulmonary nodule. Biopsy was successful in 19 of 22 nodules (86.3%). Of the 19 nodules, 12 (63.2%) were malignant and 7 (36.8%) were benign. Twelve patients (54.5%) were classified as group 1 and 10 patients (45.4%) as group 2. The distance between the lung lesion and pleura showed a statistically significant difference between these two groups: ≤ 1 cm in distance for group 1 (81.8%) and group 2 (18.2%), and > 1 cm in distance for group 1 (30%) and group 2 (70%), ρ 0.05). When early pneumothorax occurs during a biopsy, CT fluoroscopy guided percutaneous needle biopsy is an effective and safe procedure. Aggravation of pneumothorax after biopsy is affected by the depth of the pulmonary nodule

  8. Breast carcinoma in radiosurgery biopsy

    International Nuclear Information System (INIS)

    Cohen, Leonard O.; Brito, Pablo E.; Coppolecchia, German L.; Giarmana, Maria J.; Delle Ville, Rodolfo E.; Cortese, Eduardo M.

    2006-01-01

    Purpose: To report our experience on the detection of breast cancer (BC) through guided radiosurgical biopsies (GRSB) in the Gynecology Department of the Hospital Aeronautico Central (SGHAC). Materials and method: We retrospectively analyzed 622 GRSBs performed at the SGHAC between 1 January 1995 and 31 December 2004. We took into account single or associated lesions found in mammograms, which we subdivided into four types: 1) Non-palpable mammographic nodules; 2) Microcalcifications; 3) Structural distortions; 4) Mammographic asymmetries. Results: We found 332 non-palpable nodules (53.4%), 214 microcalcifications (34.4%), 40 structural distortions (6.4%), and 36 mammographic asymmetries (5.8%). Out of the 622 GRSBs performed during the above period, 152 BCs were diagnosed, that is, an incidence of 24.4% detected through this method. Out of the 152 BCs, 110 (72.4%) were invasive and 42 (27.6%) were noninvasive. Conclusions: Although 24.4% of BCs were identified through GRSBs, our tea m considers this to be the standard method for early detection of breast cancer. (author) [es

  9. The Pentapeptide Repeat Proteins

    OpenAIRE

    Vetting, Matthew W.; Hegde, Subray S.; Fajardo, J. Eduardo; Fiser, Andras; Roderick, Steven L.; Takiff, Howard E.; Blanchard, John S.

    2006-01-01

    The Pentapeptide Repeat Protein (PRP) family has over 500 members in the prokaryotic and eukaryotic kingdoms. These proteins are composed of, or contain domains composed of, tandemly repeated amino acid sequences with a consensus sequence of [S,T,A,V][D,N][L,F]-[S,T,R][G]. The biochemical function of the vast majority of PRP family members is unknown. The three-dimensional structure of the first member of the PRP family was determined for the fluoroquinolone resistance protein (MfpA) from Myc...

  10. A Video Recall Study of In-session Changes in Sentiment Override.

    Science.gov (United States)

    Johnson, Lee N; Tambling, Rachel B; Anderson, Shayne R

    2015-09-01

    This study examines in-session changes in sentiment override over the first three sessions of couple therapy. Couples viewed a video recording of therapy sessions immediately after each of the first three sessions and continuously rated their level of sentiment override. Ninety-eight changes were randomly chosen for analysis. Three talk turns prior to each change was coded using the Family Relational Communication Control Coding System. Results show that changes in sentiment override occur frequently. Repeated incidents of communication control were related to negative change in sentiment override for females. Repeated incidents of being left out of the conversation were related to negative changes in sentiment override for females and positive changes for males. © 2014 Family Process Institute.

  11. US-guided biopsy of renal allografts using 18G biopsy gun: analysis of 200 cases

    International Nuclear Information System (INIS)

    Kim, Eun Kyung; Lee, Jong Tae; Kim, Myeong Jin; Yoo, Hyung Sik; Kim, Ki Whang; Park, Ki Ill; Chung, Hyun Joo

    1995-01-01

    We evaluated the effectiveness and safety of 18G biopsy gun with US guidance in the transplanted kidneys. We performed 200 US-guided percutaneous biopsies using 18G biopsy gun. Diagnostic efficacy and complication of the biopsy in these patients were analyzed. Biopsy specimens were adequate for histologic diagnoses in 193 patients(96.5%). The mean of the biopsy frequency was 3, the mean of total glomerular number was 21.64 and the mean glomerular number per one biopsy was 6.93. Major complications occurred in 3 (1.5%) of the 200 biopsies; hematuria developed in two patients, AV fistula in one. These complications were successfully controlled either by only transfusion or by coil embolization. There were no statistical differences in blood pressure, hemoglobin, BUN/Cr between pre-and post-renal biopsies. US-guided percutaneous biopsy of renal allograft with 18G biopsy gun is simple, safe, and accurate method in evaluating the renal allograft dysfunction

  12. Repetition Performance And Blood Lactate Responses Adopting Different Recovery Periods Between Training Sessions In Trained Men.

    Science.gov (United States)

    Miranda, Humberto; de Freitas Maia, Marianna; Paz, Gabriel Andrade; de Souza, João A A A; Simão, Roberto; de Araújo Farias, Déborah; Willardson, Jeffrey M

    2017-02-08

    The purpose of this study was to examine the effect of different recovery periods (24h, 48h, and 72h) between repeated resistance training (RT) sessions for the upper body muscles on repetition performance and blood lactate responses in trained men. Sixteen recreationally trained men (age: 26.1 ± 3.1 years; height: 179 ± 4.5 cm; body mass: 82.6 ± 4.0 kg, 4.5 ± 2.2 years of RT experience) participated in this study. Eight-repetition maximum (8-RM) loads were determined for the bench press (BP), 30° incline bench press (BP30), and 45° incline bench press (BP45) exercises. To assess the effects of different recovery periods between repeated training sessions, three protocols were performed in randomized order, including: 24 hours (P24); 48 hours (P48); and 72 hours (P72). Each RT session consisted of performing four repetition maximum sets of BP, BP30, and BP45 with 8-RM loads and 2-minute rest intervals between sets. Blood lactate levels were measured pre-session (PRE), immediately post-session (POST), 3 minutes post-session (P3), and 5 minutes post-session (P5). For the P24 protocol, significant decreases in repetition performance were found between sessions for the BP, BP30, and BP45 exercises, respectively. When considering session 2 only, the total work (repetition x sets) was significantly higher in P48 and P72 versus P24 for the BP30 and BP45 exercises. Blood lactate levels (i.e. POST, P3, and P5) significantly increased for session 2 under the P24 compared to the P48 and P72 protocols, respectively. Therefore, coaches and practitioners who need to accomplish a higher training volume for the upper body muscles should adopt recovery periods longer than 24 hours between sessions that train the same or similar muscle groups.

  13. Working session 3: Tubing integrity

    International Nuclear Information System (INIS)

    Cueto-Felgueroso, C.; Strosnider, J.

    1997-01-01

    Twenty-three individuals representing nine countries (Belgium, Canada, the Czech Republic, France, Japan, the Slovak Republic, Spain, the UK, and the US) participated in the session on tube integrity. These individuals represented utilities, vendors, consultants and regulatory authorities. The major subjects discussed by the group included overall objectives of managing steam generator tube degradation, necessary elements of a steam generator degradation management program, the concept of degradation specific management, structural integrity evaluations, leakage evaluations, and specific degradation mechanisms. The group's discussions on these subjects, including conclusions and recommendations, are summarized in this article

  14. CIME Session on Pluripotential Theory

    CERN Document Server

    Patrizio, Giorgio; Berteloot, Francois; Demailly, Jean Pierre

    2013-01-01

    Pluripotential theory is a very powerful tool in geometry, complex analysis and dynamics. This volume brings together the lectures held at the 2011 CIME session on "pluripotential theory" in Cetraro, Italy. This CIME course focused on complex Monge-Ampére equations, applications of pluripotential theory to Kahler geometry and algebraic geometry and to holomorphic dynamics. The contributions provide an extensive description of the theory and its very recent developments, starting from basic introductory materials and concluding with open questions in current research.

  15. Summary of spin physics sessions

    International Nuclear Information System (INIS)

    Roser, T.

    1988-01-01

    The list of topics in the many talks given during the Spin Physics sessions of this Intersections conference is nearly as long as the one of this conference: P and T Violation NN Interaction πp and πd Elastic Scattering Nuclear Matter Spin Effects Muon (g-2) Polarized Proton Beams Polarized Gas Targets This points to the almost trivial fact that spin is fundamental to our understanding of nuclear and particle physics. I will discuss in some detail only four of these topics. Needless to say this choice is very much personally biased and I apologize to all the speakers whose excellent contributions I did not include

  16. Repeated Causal Decision Making

    Science.gov (United States)

    Hagmayer, York; Meder, Bjorn

    2013-01-01

    Many of our decisions refer to actions that have a causal impact on the external environment. Such actions may not only allow for the mere learning of expected values or utilities but also for acquiring knowledge about the causal structure of our world. We used a repeated decision-making paradigm to examine what kind of knowledge people acquire in…

  17. simple sequence repeat (SSR)

    African Journals Online (AJOL)

    In the present study, 78 mapped simple sequence repeat (SSR) markers representing 11 linkage groups of adzuki bean were evaluated for transferability to mungbean and related Vigna spp. 41 markers amplified characteristic bands in at least one Vigna species. The transferability percentage across the genotypes ranged ...

  18. Transvenous liver biopsy via the femoral vein

    International Nuclear Information System (INIS)

    Khosa, F.; McNulty, J.G.; Hickey, N.; O'Brien, P.; Tobin, A.; Noonan, N.; Ryan, B.; Keeling, P.W.N.; Kelleher, D.P.; McDonald, G.S.A.

    2003-01-01

    AIM: To study the safety, effectiveness and diagnostic value of transvenous forceps biopsy of the liver in 54 patients with coagulopathy, gross ascites or morbid obesity and suspected liver disease in whom percutaneous liver biopsy was contraindicated. MATERIAL AND METHODS: Forceps biopsy of the liver via the femoral vein was attempted in 54 adult patients with advanced liver disease of unknown aetiology who had coagulation disorders (41 cases), gross ascites (11 cases) or morbid obesity (two cases). In each patient two to six biopsies (average four) were taken using a radial jaw forceps inserted via the right or left femoral vein. RESULTS: The procedure was successful in 53 cases. Hepatic vein catheterization failed in one patient. Adequate liver tissue for diagnosis was obtained in 84% of cases. One patient developed delayed haemorrhage at 12 h from a capsular leak that was undetected during the biopsy procedure. This patient required blood transfusions and laparotomy to control bleeding. There were no deaths in the 53 patients studied. Transient minor chest and shoulder pain was encountered during sheath insertion into a hepatic vein in 23 patients. Three patients developed a femoral vein haematoma, which resolved with conservative treatment. CONCLUSION: Transvenous liver biopsy via the femoral vein is another safe, effective, simple alternative technique of biopsy when the percutaneous route is contraindicated

  19. Working session 1: Tubing degradation

    International Nuclear Information System (INIS)

    Kharshafdjian, G.; Turluer, G.

    1997-01-01

    A general introductory overview of the purpose of the group and the general subject area of SG tubing degradation was given by the facilitator. The purpose of the session was described as to open-quotes develop conclusions and proposals on regulatory and technical needs required to deal with the issues of SG tubing degradation.close quotes Types, locations and characteristics of tubing degradation in steam generators were briefly reviewed. The well-known synergistic effects of materials, environment, and stress and strain/strain rate, subsequently referred to by the acronym open-quotes MESSclose quotes by some of the group members, were noted. The element of time (i.e., evolution of these variables with time) was emphasized. It was also suggested that the group might want to consider the related topics of inspection capabilities, operational variables, degradation remedies, and validity of test data, and some background information in these areas was provided. The presentation given by Peter Millet during the Plenary Session was reviewed; Specifically, the chemical aspects and the degradation from the secondary side of the steam generator were noted. The main issues discussed during the October 1995 EPRI meeting on secondary side corrosion were reported, and a listing of the potential SG tube degradations was provided and discussed

  20. Die Biopsie von Knochen- und Weichteiltumoren

    OpenAIRE

    Fuchs, B

    2008-01-01

    Technisch stellt die Biopsie von Knochen- und Weichteiltumoren einen simplen Akt dar, intellektuell aber ist die Planung einer Biopsie höchst anspruchsvoll. Zu häufig werden heutzutage immer noch Biopsien unsachgemäss durchgeführt, so dass die Behandlung - im besten Fall - erschwert wird. Eine unsachgemäss durchgeführte Biopsie führt häufig zu negativen funktionellen Konsequenzen für den Patienten, im schlimmsten Fall kann es die Prognose direkt beeinträchtigen. Aus diesem Grund soll...

  1. A randomised pilot study comparing 13 G vacuum-assisted biopsy and conventional 14 G core needle biopsy of axillary lymph nodes in women with breast cancer

    International Nuclear Information System (INIS)

    Maxwell, A.J.; Bundred, N.J.; Harvey, J.; Hunt, R.; Morris, J.; Lim, Y.Y.

    2016-01-01

    Aim: To compare the acceptability, safety, and feasibility of vacuum-assisted biopsy (VAB) and core needle biopsy (CNB) of axillary lymph nodes in women with breast cancer. Materials and methods: This parallel, non-blinded, randomised study was approved by the National Research Ethics Service. Following written informed consent, women with abnormal appearing axillary lymph nodes and radiologically malignant breast masses were randomised 1:1 to lymph node sampling under local anaesthetic with either 14 G CNB or 13 G VAB in a single UK centre. Primary outcomes were study uptake rate and patient willingness to undergo a repeat procedure if necessary. Procedure duration, immediate and post-procedure pain scores, diagnostic yield, complications, and surgical histopathology were recorded. Results: Ninety-five women were approached; 81 (85.3%) consented and were randomised. Forty underwent CNB; 40 underwent VAB; one was excluded. Median age was 57 years. The median procedure time was 2 minutes for both techniques. The median number of samples obtained was three for CNB and four for VAB. Median pain scores for the procedure and first 3 days were 1/10 and 1/10 for CNB and 1/10 and 2/10 for VAB (p=0.11 and 0.04). More women were prepared to undergo repeat CNB compared to VAB, but the difference was not significant (38/39 versus 33/39; p=0.11). Two patients developed a haematoma after VAB. One CNB and six VABs failed to yield adequate tissue (p=0.11), but the sensitivity was similar at 79% and 78%. Conclusion: Study uptake was high. Acceptability of the two procedures was similar, but VAB was associated with more post-procedure pain. The sensitivity appears to be similar. - Highlights: • Vacuum biopsy of axillary lymph nodes can be performed rapidly. • Post-procedure pain was slightly higher in women who underwent vacuum biopsy. • The inadequate yield rate of vacuum biopsy may be higher than that for core biopsy. • Sensitivity of 13-gauge vacuum biopsy and 14-gauge

  2. Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid An ... Aspiration Biopsy of the Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? During ...

  3. Ultrasound guided pleural biopsy in undiagnosed exudative pleural effusion patients

    Directory of Open Access Journals (Sweden)

    Adel S. Ahmed

    2016-04-01

    In conclusion: Thoracic ultrasound (TUS guided pleural biopsy had a diagnostic yield which was slightly lower but comparable to both CT guided pleural biopsy and medical thoracoscopic pleural biopsy (MT.

  4. MR imaging-guided vacuum-assisted breast biopsy: Reduction of false-negative biopsies by short-term control MRI 24–48 h after biopsy

    International Nuclear Information System (INIS)

    Bahrs, S.D.; Hattermann, V.; Preibsch, H.; Hahn, M.; Staebler, A.; Claussen, C.D.; Siegmann-Luz, K.C.

    2014-01-01

    Aim: To evaluate whether another contrast-enhanced (CE) magnetic resonance imaging (MRI) examination 24–48 h after MRI-guided vacuum-assisted breast biopsy (MRI-VAB) can reduce the rate of false-negative cases. Materials and methods: The study included 252 patients who underwent MRI-VAB for the clarification of 299 lesions. The success of MRI-VAB was assessed at interventional MRI and another CE MRI 24–48 h after the intervention. In cases of successful MRI-VAB (complete or partial lesion removal) and benign histological results, follow-up breast MRI was performed. In cases of unsuccessful biopsy (unchanged lesion), tissue sampling was repeated. False-negative cases were calculated to assess the diagnostic value of MRI follow-up within 2 days after intervention. Results: Ninety-eight malignant (32.8%) and 201 (67.2%) benign lesions were diagnosed using MRI-VAB. At immediate unenhanced control MRI, all lesions were assessed as successfully biopsied. In 18 benign cases (6%), CE MRI after 24–48 h showed an unsuccessful intervention. Further tissue sampling revealed another 13 cancers in these patients. This results in a false-negative rate of 11.7%. Follow-up MRI of the benign lesions presented no further malignancy. Conclusions: MRI-VAB with immediate unenhanced control offers a success rate of 94%. The rate of false-negative biopsies (11.7%) could be reduced to zero by using short-term follow-up MRI. Therefore, a further CE breast MRI 24–48 h after benign MRI-VAB to eliminate missed cancers is recommended. - Highlights: • Some suspicious breast lesions are only seen on MRI. • They can be biopsied by a MRI-guided vacuum-assisted biopsy system. • Inadequate sampling causes some false-negative biopsies. • We evaluate an additional control MRI 24 to 48 hours after biopsy. • A reduced rate of the false-negative biopsies was found

  5. Clinical application of Lin's biopsy grasper for intrauterine targeted biopsy and polypectomy during office hysteroscopy.

    Science.gov (United States)

    Cheng, Hsin-Yi; Lin, Bao-Liang; Tseng, Jen-Yu; Ueno, Kazunori; Nakada, Sakura

    2018-06-01

    Hysteroscopy has widely been used for diagnosis of the uterine cavity; however, target biopsy has often been difficult in part to the inherent limitations of ancillary instruments. Lin's biopsy grasper was specifically designed to work in conjunction with a flexible hysteroscope to obtain intrauterine biopsy under transabdominal sonography. Herein, we share our clinical experience in the management of endometrial abnormalities with the use of Lin's biopsy grasper during office-based hysteroscopy. From February 2006 to November 2016, the use of Lin's biopsy grasper for tissue biopsy was attempted on 126 cases. We retrospectively recorded and analyzed the patients' preoperative characteristics and biopsy outcomes to demonstrate the feasibility and efficacy of Lin's biopsy grasper. Out of the one hundred and twenty-six enrolled patients, satisfactory targeted biopsies were achieved; including high diagnostic rate (92.1%, with 116 cases confirmed histologically) and adequate tissue retrieval (77.8%, with 98 cases obtaining optimal specimen volume). All patients tolerated the procedure without analgesics or anesthesia. Diagnostic flexible hysteroscopy combined with the use of Lin's biopsy grasper has proven to be an effective tool for intrauterine evaluation and obtaining tissue sample. Copyright © 2018. Published by Elsevier B.V.

  6. Sentinel node biopsy in penile cancer

    DEFF Research Database (Denmark)

    Jakobsen, J. K.; Krarup, K. P.; Sommer, P.

    2015-01-01

    INTRODUCTION & OBJECTIVES: Nodal involvement is a strong prognosticator in penile cancer and lymph node staging is crucial. Sentinel node biopsy (SNB) has proven a useful staging tool with few complications, but evidence rely mostly on single institution publications with a short follow-up. In th......INTRODUCTION & OBJECTIVES: Nodal involvement is a strong prognosticator in penile cancer and lymph node staging is crucial. Sentinel node biopsy (SNB) has proven a useful staging tool with few complications, but evidence rely mostly on single institution publications with a short follow...... died from complications. CONCLUSIONS: To our knowledge, this is the first complete national study on sentinel node biopsy. Penile cancer sentinel node biopsy with a close follow-up is a reliable lymph node staging and has few complications in a national multicentre setting. Inguinal lymph node...

  7. Computed tomography guidance for skeletal biopsy

    International Nuclear Information System (INIS)

    Frager, D.H.; Goldman, M.J.; Elkin, C.M.; Cynamon, J.; Leeds, N.E.; Seimon, L.P.; Habermann, E.T.; Schreiber, K.; Freeman, L.M.

    1987-01-01

    Computed tomographic (CT) guided biopsy and abscess drainage of multiple organ systems have been well described. Reports of spinal and skeletal applications have been less common. This study describes the use of CT guidance in the biopsy of various skeletal lesions in 46 patients. Forty-one patients had skinny needle aspirations (18 or 22 gauge) and 23 patients had trephine core biopsies. Sites of the lesions included: thoracic spine - 15 patients, lumbosacral spine - 17 patients, bony pelvis - 6 patients, rib - 2 patients, and long bones - 6 patients. Fast scanners capable of rapid image reconstruction have overcome many constraints. With CT guidance, the physician who performs the procedure receives virtually no ionizing radiation. The exact location of the needle tip is accurately visualized in relation to the lesion being biopsied and to the vital organs. (orig.)

  8. Magnetic Resonance (MR)-Guided Breast Biopsy

    Science.gov (United States)

    ... over time. top of page What are the benefits vs. risks? Benefits The procedure is less invasive than surgical biopsy, ... risk of infection. The chance of infection requiring antibiotic treatment appears to be less than one in ...

  9. GoM Coastal Biopsy Surveys - NRDA

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Small vessel surveys were conducted within estuarine and nearshore coastal waters of Barataria Bay, LA and Mississippi Sound, MS to collect tissue biopsy samples...

  10. morphological pattern of endometrial biopsies in south

    African Journals Online (AJOL)

    Method: A retrospective study was undertaken to review all cases of endometrial biopsies ... MATERIALS AND METHODS. A retrospective ... tumours, 10 (0.4%) mixed tumours, 14 (0.6%) ..... accurate and concise clinical information on the.

  11. Outpatient percutaneous renal biopsy in adult patients

    International Nuclear Information System (INIS)

    Al-Hweish, Abdulla K.; Abdul-Rehman, I. Saeed

    2007-01-01

    To study the safety and efficacy of performing percutanaeous renal biopsy in the outpatient department compared to the traditional inpatient policy, we studied 44 consecutive patients with proteinuria and other urinary sediment abnormalities, at King Fahd Hospital of the University, Al-Khobar, Saudi Arabia, during the period from September 2004 to August 2006. The patients were divided into two groups: group I, in whom kidney biopsy was performed and followed by 1-day hospital admission; and group II, in whom renal biopsy was performed in the outpatient department and followed by 6 hours observation period and then by regular outpatient visits. All biopsies were performed with the use of real-time ultrasound and automated biopsy needle. Patients with a history of bleeding diathesis or abnormal coagulation profile and those receiving warfarin, heparin, aspirin or nonsteroidal anti-inflammatory drugs were excluded from the study. Only minor biopsy-related complications such as gross hematuria, perinephric hematoma that resolved without the need for blood transfusion or surgical intervention occurred in three (13.6%) patients in group I and in two (9.1%) patients in group II. The complications were apparent within 6 hours in all but one patient (97.7%). Overall, hematuria was identified in 52% of patients at <-72 hours, 85% at <-4 hours and 97.7% at <- 6 hours. The 24-hour hematocrit levels were not significantly different between the study groups. One (4.5%) patient from group II had a small perinephric hematoma, which was detected by ultrasound examination at 24 hours but not at 6 hours post biopsy period; it resolved spontaneously without intervention. We conclude that in selected patients, same day discharge after 6 hours of renal biopsy may be given safety without increased risk of complications. (author)

  12. Transbronchial biopsies safely diagnose amyloid lung disease

    Science.gov (United States)

    Govender, Praveen; Keyes, Colleen M.; Hankinson, Elizabeth A.; O’Hara, Carl J.; Sanchorawala, Vaishali; Berk, John L.

    2018-01-01

    Background Autopsy identifies lung involvement in 58–92% of patients with the most prevalent forms of systemic amyloidoses. In the absence of lung biopsies, amyloid lung disease often goes unrecognized. Report of a death following transbronchial biopsies in a patient with systemic amyloidosis cautioned against the procedure in this patient cohort. We reviewed our experience with transbronchial biopsies in patients with amyloidosis to determine the safety and utility of bronchoscopic lung biopsies. Methods We identified patients referred to the Amyloidosis Center at Boston Medical Center with lung amyloidosis diagnosed by transbronchial lung biopsies (TBBX). Amyloid typing was determined by immunohistochemistry or mass spectrometry. Standard end organ assessments, including pulmonary function test (PFT) and chest tomography (CT) imaging, and extra-thoracic biopsies established the extent of disease. Results Twenty-five (21.7%) of 115 patients with lung amyloidosis were diagnosed by TBBX. PFT classified 33.3% with restrictive physiology, 28.6% with obstructive disease, and 9.5% mixed physiology; 9.5% exhibited isolated diffusion defects while 19% had normal pulmonary testing. Two view chest or CT imaging identified focal opacities in 52% of cases and diffuse interstitial disease in 48%. Amyloid type and disease extent included 68% systemic AL disease, 16% localized (lung limited) AL disease, 12% ATTR disease, and 4% AA amyloidosis. Fluoroscopy was not used during biopsy. No procedure complications were reported. Conclusions Our case series of 25 patients supports the use of bronchoscopic transbronchial biopsies for diagnosis of parenchymal lung amyloidosis. Normal PFTs do not rule out the histologic presence of amyloid lung disease. PMID:28393574

  13. Working session 2: Tubing inspection

    International Nuclear Information System (INIS)

    Guerra, J.; Tapping, R.L.

    1997-01-01

    This session was attended by delegates from 10 countries, and four papers were presented. A wide range of issues was tabled for discussion. Realizing that there was limited time available for more detailed discussion, three topics were chosen for the more detailed discussion: circumferential cracking, performance demonstration (to focus on POD and sizing), and limits of methods. Two other subsessions were organized: one dealt with some challenges related to the robustness of current inspection methods, especially with respect to leaving cracked tubes in service, and the other with developing a chart of current NDE technology with recommendations for future development. These three areas are summarized in turn, along with conclusions and/or recommendations. During the discussions there were four presentations. There were two (Canada, Japan) on eddy current probe developments, both of which addressed multiarray probes that would detect a range of flaws, one (Spain) on circumferential crack detection, and one (JRC, Petten) on the recent PISC III results

  14. Cinema Sessions in Primary Care

    Directory of Open Access Journals (Sweden)

    Francisco Ignacio MORETA-VELAYOS

    2016-04-01

    Full Text Available For a long time films have been used in teaching and at various levels of professional training  and more specifically in the medical area. In this case, through the description of a project developed in a Primary Care Health Center, we intend to justify the use of movies as a tool that could ease, the sometimes difficult task of continued education among Primary Care professionals. We propose different aspects of everyday practice in which cinema can be potentially useful, as well as the way to include it in the Plan of Continued Education of the Centre and its accreditation.Films and issues discussed in each session, and the project evaluation, are detailed.

  15. DWPF recycle minimization: Brainstorming session

    International Nuclear Information System (INIS)

    Jacobs, R.A.; Poirier, M.R.

    1993-01-01

    The recycle stream from the DWPF constitutes a major source of water addition to the High Level Waste evaporator system. As now designed, the entire flow of 3.5 to 6.5 gal/min (at sign 25% and 75% attainment, respectively), or 2 gal/min during idling, flow to the 2H evaporator system (Tank 43). Substantial improvement in the HLW water balance and tank volume management is expected if the DWPF recycle to the HLW evaporator system can be significantly reduced. A task team has been appointed to study alternatives for reducing the flow to the HLW evaporator system and make recommendations for implementation and/or further study and evaluation. The brainstorming session detailed in this report was designed to produce the first cut options for the task team to further evaluate

  16. Celebrating the tenth conference session

    International Nuclear Information System (INIS)

    1966-01-01

    Full text: This number of the Bulletin appears during a month when the tenth regular session of the Agency's General Conference is being held. It is fitting that among the special arrangements made to give added significance to such an historical landmark should be an opening address by Herr Franz Jonas, Federal President of the host country, Austria. The Festsaal of the Kongresszentrum, in the Hofburg, has now been the centre for every annual session held in Austria, except the first. On that occasion, recorded in the photograph on the cover, the Konzerthaus was made available. A commemorative series of talks dealing with topics of particular interest in the international development of the peaceful uses of atomic energy, delivered by scientists of world distinction was another idea which will add much profound thought to the records of nuclear energy. Under the chairmanship of Professor L.C. Prado, with Dr. W.B. Lewis as Moderator, the subjects chosen by the participants were : The Impact of Atomic Energy in our Society - Sir John Cockcroft; Nuclear Power Systems and their Technical Potentialities - Prof. Alexandre Leipunski; The Commercial Future of Nuclear Power - Dr. William Webster; Nuclear Science in Life Sciences - Dr. A.R. Gopal-Ayengar; Fundamental Research in Atomic Energy Centres - Prof. Louis Neel. These speeches will be reproduced in full in the Agency's Atomic Energy Review. The pages of this issue of the Bulletin are intended to give indications of the stage which the Agency has now reached in some, but by no means all, of its activities in promoting the techniques of atomic energy for the benefit of mankind. (author)

  17. Ultrasound-guided percutaneous renal biopsy with an automated biopsy gun in diffuse renal disease

    International Nuclear Information System (INIS)

    Kim, Ji Yang; Moon, Jeoung Mi; Park, Ji Hyun; Kwon, Jae Soo; Song, Ik Hoon; Kim, Sung Rok

    1994-01-01

    We evaluated the effectiveness and clinical usefulness of percutaneous renal biopsy by using automated biopsy gun under the real-time ultrasonographic guidance that was performed in 17 patients with diffuse renal disease. We retrospectively analysed the histopathological diagnosis and the patients' status after percutaneous renal biopsy.Adequate amount of tissue for the histologic diagnosis could be obtained in al patients. Histopathologic diagnosis included the minimal change nephrotic syndrome in 6 patients, the membrano proliferative glomerulonephritis in 4,the membranous glomerulonephritis in 2, the glomerulosclerosis in 2, Ig A nephropathy in 2, and the normal finding in 1. Significant complication occurred in only one patient who developed a transient loss of sensation at and around the biopsy site. In conclusion, automated biopsy gun was a very useful device in performing percutaneous biopsy for diffuse renal disease with a high success rate and a low complication rate

  18. The gene expression and immunohistochemical time-course of diphenylcyclopropenone induced contact allergy in healthy humans following repeated epicutaneous challenges

    DEFF Research Database (Denmark)

    Mose, K F; Burton, M; Thomassen, M

    2017-01-01

    challenges with DPCP to find the predominant gene expression pattern, ii) the time-course of cell infiltration following repeated DPCP challenges, and iii) the transcriptome of a repeated CA exposure model. We obtained punch biopsies from control and DPCP exposed skin from ten DPCP sensitized individuals...

  19. The Effects of Repeated Exposure to Graphic Fear Appeals on Cigarette Packages: A Field Experiment

    NARCIS (Netherlands)

    Dijkstra, A.; Bos, C.

    2015-01-01

    Experimental studies on the effects of graphic fear appeals on cigarette packages typically expose smokers in a single session to a fear appeal, although in practice the exposure is always repeated. The present study applied an improved study design with repeated exposure to fear appeals on

  20. The Effects of Repeated Exposure to Graphic Fear Appeals on Cigarette Packages : A Field Experiment

    NARCIS (Netherlands)

    Dijkstra, Arie; Colin, Bos,

    2015-01-01

    Experimental studies on the effects of graphic fear appeals on cigarette packages typically expose smokers in a single session to a fear appeal, although in practice the exposure is always repeated. The present study applied an improved study design with repeated exposure to fear appeals on

  1. Gene expression in human skeletal muscle: alternative normalization method and effect of repeated biopsies

    DEFF Research Database (Denmark)

    Lundby, Carsten; Nordsborg, Nikolai; Kusuhara, K.

    2005-01-01

    standards revealed a high degree of sensitivity and linearity (2.5-45 ng; R 2>0.99) with OliGreen reagent, as was the case for OliGreen analyses with standard curves constructed from serial dilutions of representative RT samples (R 2 >0.99 for a ten times dilution range of a representative reversed...

  2. Liver Biopsies for Chronic Hepatitis C: Should Nonultrasound-Guided Biopsies Be Abandoned?

    Directory of Open Access Journals (Sweden)

    Jennifer A Flemming

    2009-01-01

    Full Text Available BACKGROUND/OBJECTIVE: Liver biopsy has been the gold standard for grading and staging chronic hepatitis C virus (HCV-mediated liver injury. Traditionally, this has been performed by trained practitioners using a nonimage-guided percutaneous technique at the bedside. Recent literature suggests an expanding role for radiologists in obtaining biopsies using an ultrasound (US-guided technique. The present study was undertaken study to determine if the two techniques produced liver biopsy specimens of similar quality and hypothesized that at our institution, non-US-guided percutaneous liver biopsies for HCV would be of higher quality than US-guided specimens.

  3. Session Report - S. Voinis (Andra)

    International Nuclear Information System (INIS)

    Voinis, Sylvie

    2014-01-01

    The session addressed key issues related to the industrial feasibility of construction. It covered the implementer and regulator points of view. The conclusions derive from three presentations completed by the outcomes of six WG. At the Morsleben Repository, Germany, the licensing of the closure of the repository has been initiated by BfS. The closure concept is based on extensive backfilling with salt concrete complemented by seals. In order to demonstrate the feasibility of constructing such a seal structure an in-situ experiment is performed in a drift of the repository. In the UK, the framework for implementing geological disposal of the higher activity radioactive waste is described in the White Paper published by the UK Government in June 2008. The process to site a facility will be staged and based on voluntarism and partnership with local communities. This process is in its early stage. The paper outlines the work being undertaken by the NDA. In canada, Ontario Power Generation (OPG) has submitted information required for a CNSC licence to prepare the site and construct a DGR for the disposal of low and intermediate level waste from the operation of their nuclear power reactors. That submission includes an Environmental Impact Statement (EIS), as required for a Panel Review under the Canadian Environmental Assessment Act (CEAA), and the information required for a licence application under the NSCA Regulations. Discussions between the proponent and the regulator in the pre-licensing phase, clarified CNSC expectations for the characterization of the site and for the development of the EIS and application. They also helped to ensure that OPG understood these expectations. Outcomes WG session-1: - Start with construction but during operational phase: Simultaneous construction and operation activities. - Need for technical requirements/criteria: So that it can be judged whether 'products' meet the requirements; LT safety issues to be considered during

  4. Image-guided procedures in brain biopsy.

    Science.gov (United States)

    Fujita, K; Yanaka, K; Meguro, K; Narushima, K; Iguchi, M; Nakai, Y; Nose, T

    1999-07-01

    Image-guided procedures, such as computed tomography (CT)-guided stereotactic and ultrasound-guided methods, can assist neurosurgeons in localizing the relevant pathology. The characteristics of image-guided procedures are important for their appropriate use, especially in brain biopsy. This study reviewed the results of various image-guided brain biopsies to ascertain the advantages and disadvantages. Brain biopsies assisted by CT-guided stereotactic, ultrasound-guided, Neuronavigator-guided, and the combination of ultrasound and Neuronavigator-guided procedures were carried out in seven, eight, one, and three patients, respectively. Four patients underwent open biopsy without a guiding system. Twenty of 23 patients had a satisfactory diagnosis after the initial biopsy. Three patients failed to have a definitive diagnosis after the initial procedure, one due to insufficient volume sampling after CT-guided procedure, and two due to localization failure by ultrasound because the lesions were nonechogenic. All patients who underwent biopsy using the combination of ultrasound and Neuronavigator-guided methods had a satisfactory result. The CT-guided procedure provided an efficient method of approaching any intracranial target and was appropriate for the diagnosis of hypodense lesions, but tissue sampling was sometimes not sufficient to achieve a satisfactory diagnosis. The ultrasound-guided procedure was suitable for the investigation of hyperdense lesions, but was difficult to localize nonechogenic lesions. The combination of ultrasound and Neuronavigator methods improved the diagnostic accuracy even in nonechogenic lesions such as malignant lymphoma. Therefore, it is essential to choose the most appropriate guiding method for brain biopsy according to the radiological nature of the lesions.

  5. Ultrasound-guided diagnostic breast biopsy methodology: retrospective comparison of the 8-gauge vacuum-assisted biopsy approach versus the spring-loaded 14-gauge core biopsy approach

    Science.gov (United States)

    2011-01-01

    Background Ultrasound-guided diagnostic breast biopsy technology represents the current standard of care for the evaluation of indeterminate and suspicious lesions seen on diagnostic breast ultrasound. Yet, there remains much debate as to which particular method of ultrasound-guided diagnostic breast biopsy provides the most accurate and optimal diagnostic information. The aim of the current study was to compare and contrast the 8-gauge vacuum-assisted biopsy approach and the spring-loaded 14-gauge core biopsy approach. Methods A retrospective analysis was done of all ultrasound-guided diagnostic breast biopsy procedures performed by either the 8-gauge vacuum-assisted biopsy approach or the spring-loaded 14-gauge core biopsy approach by a single surgeon from July 2001 through June 2009. Results Among 1443 ultrasound-guided diagnostic breast biopsy procedures performed, 724 (50.2%) were by the 8-gauge vacuum-assisted biopsy technique and 719 (49.8%) were by the spring-loaded 14-gauge core biopsy technique. The total number of false negative cases (i.e., benign findings instead of invasive breast carcinoma) was significantly greater (P = 0.008) in the spring-loaded 14-gauge core biopsy group (8/681, 1.2%) as compared to in the 8-gauge vacuum-assisted biopsy group (0/652, 0%), with an overall false negative rate of 2.1% (8/386) for the spring-loaded 14-gauge core biopsy group as compared to 0% (0/148) for the 8-gauge vacuum-assisted biopsy group. Significantly more (P guided diagnostic breast biopsy procedure. Significantly more (P guided diagnostic breast biopsy procedure. Conclusions In appropriately selected cases, the 8-gauge vacuum-assisted biopsy approach appears to be advantageous to the spring-loaded 14-gauge core biopsy approach for providing the most accurate and optimal diagnostic information. PMID:21835024

  6. Small renal mass biopsy--how, what and when: report from an international consensus panel.

    Science.gov (United States)

    Tsivian, Matvey; Rampersaud, Edward N; del Pilar Laguna Pes, Maria; Joniau, Steven; Leveillee, Raymond J; Shingleton, William B; Aron, Monish; Kim, Charles Y; DeMarzo, Angelo M; Desai, Mihir M; Meler, James D; Donovan, James F; Klingler, Hans Christoph; Sopko, David R; Madden, John F; Marberger, Michael; Ferrandino, Michael N; Polascik, Thomas J

    2014-06-01

    To discuss the use of renal mass biopsy (RMB) for small renal masses (SRMs), formulate technical aspects, outline potential pitfalls and provide recommendations for the practicing clinician. The meeting was conducted as an informal consensus process and no scoring system was used to measure the levels of agreement on the different topics. A moderated general discussion was used as the basis for consensus and arising issues were resolved at this point. A consensus was established and lack of agreement to topics or specific items was noted at this point. Recommended biopsy technique: at least two cores, sampling different tumour regions with ultrasonography being the preferred method of image guidance. Pathological interpretation: 'non-diagnostic samples' should refer to insufficient material, inconclusive and normal renal parenchyma. For non-diagnostic samples, a repeat biopsy is recommended. Fine-needle aspiration may provide additional information but cannot substitute for core biopsy. Indications for RMB: biopsy is recommended in most cases except in patients with imaging or clinical characteristics indicative of pathology (syndromes, imaging characteristics) and cases whereby conservative management is not contemplated. RMB is recommended for active surveillance but not for watchful-waiting candidates. We report the results of an international consensus meeting on the use of RMB for SRMs, defining the technique, pathological interpretation and indications. © 2013 The Authors. BJU International © 2013 BJU International.

  7. Use of percutaneous image-guided coaxial core-needle biopsy for diagnosis of intraabdominal lymphoma

    International Nuclear Information System (INIS)

    Shimizu, Ikuo; Okazaki, Yoichi; Takeda, Wataru; Kirihara, Takehiko; Sato, Keijiro; Fujikawa, Yuko; Ueki, Toshimitsu; Hiroshima, Yuki; Sumi, Masahiko; Ueno, Mayumi; Ichikawa, Naoaki; Kobayashi, Hikaru

    2014-01-01

    Although pathological diagnosis is essential for managing malignant lymphoma, intraabdominal lesions are generally difficult to approach due to the invasiveness of abdominal surgery. Here, we report the use of percutaneous image-guided coaxial core-needle biopsy (CNB) to obtain intraabdominal specimens for diagnosing intraabdominal lymphomas, which typically requires histopathological and immunohistochemical evaluation. We retrospectively reviewed consecutive cases involving computed tomography (CT)- or ultrasonography (US)-guided CNB to obtain pathological specimens for intraabdominal lesions from 1999 to 2011. Liver, spleen, kidney, and inguinal node biopsies were excluded. We compared CNBs with laparotomic biopsies. A total of 66 CNBs were performed for 59 patients (32 males, 27 females; median age, 63.5), including second or third repeat procedures. Overall diagnostic rate was 88.5%. None of the patients required additional surgical biopsies. Notably, the median interval between recognition of an intraabdominal mass and biopsy was only 1 day. Forty-five procedures were performed for hematological malignancies. Adequate specimens were obtained for histopathological diagnosis in 86% of cases. Flow cytometry detected lymphoma cells in 79.5% of cases. Twelve patients (nine males, three females; median age, 60) were eligible for surgical biopsy. While every postoperative course was satisfactory, median duration from lesion recognition to therapy initiation for lymphoma cases was significantly shorter for CNB than for surgical biopsy (14 vs. 35 days). While one-fourth of the patients were not eligible for the procedures, CNB is safe and highly effective for diagnosis of intraabdominal lymphomas. This method significantly improves sampling and potentially helps attain immunohistological distinction, allowing for more timely therapy initiation

  8. CT fluoroscopy guided transpleural cutting needle biopsy of small ({<=}2.5 cm) subpleural pulmonary nodules

    Energy Technology Data Exchange (ETDEWEB)

    Prosch, Helmut; Oschatz, Elisabeth; Eisenhuber, Edith; Wohlschlager, Helmut [Otto Wagner Hospital, Department of Radiology, Sanatoriumsstrasse 2, 1140 Vienna (Austria); Mostbeck, Gerhard H., E-mail: gerhard.mostbeck@wienkav.at [Otto Wagner Hospital, Department of Radiology, Sanatoriumsstrasse 2, 1140 Vienna (Austria)

    2011-01-15

    Purpose: Small subpleural pulmonary lesions are difficult to biopsy. While the direct, short needle path has been reported to have a lower rate of pneumothorax, the indirect path provides a higher diagnostic yield. Therefore, we tried to optimize the needle pathway and minimize the iatrogenic pneumothorax risk by evaluating a CT fluoroscopy guided direct approach to biopsy subpleural lesions. Material and methods: Between 01/2005 and 01/2007, CT fluoroscopy guided core biopsies were performed in 24 patients. Using our technique, the tip of the guide needle remains outside the visceral pleura (17 G coaxial guide needle, 18 G Biopsy-gun, 15 or 22 mm needle path). The position of the lesion relative to the needle tip can be optimized using CT fluoroscopy by adjusting the breathing position of the patient. The Biopty gun is fired with the needle tip still outside the pleural space. Cytological smears are analyzed by a cytopathologist on-site, and biopsies are repeated as indicated with the coaxial needle still outside the pleura. Results: Median nodule size was 1.6 cm (0.7-2.3 cm). A definitive diagnosis was obtained in 22 patients by histology and/or cytology. In one patient, only necrotic material could be obtained. In another patient, the intervention had to be aborted as the dyspnoic patient could not follow breathing instructions. An asymptomatic pneumothorax was present in seven patients; chest tube placement was not required. Conclusion: The presented biopsy approach has a high diagnostic yield and is especially advantageous for biopsies of small subpleural lesions in the lower lobes.

  9. Session II-D. Systems

    International Nuclear Information System (INIS)

    Hall, R.J.

    1981-01-01

    The objectives of the Systems Task in the NWTS Program include: development of program requirements, allocation of the requirements to subsystems or tasks, integration of the task activities towards meeting the overall requirements, and assessment of progress towards achievement of the program mission. The Systems Task also includes a number of ancillary activities which are necessary to the program but which do not logically fall into other work-breakdown structure elements. Activities in the Systems Task, which in the NWTS Program are conducted at both the program and project levels, are generally grouped under the heading systems engineering and include identification of requirements, development of a baseline, integration of the system, baseline control, functional analyses, trade-off studies, and system analyses. The following papers in this session address some of the activities and progress that was achieved in the Systems Task in FY 1981: (1) waste isolation system alternatives: a cost comparison; (2) BWIP technical integration and control; (3) BWIP performance evaluation process: a criteria based method; (4) impacts of waste age; (5) systems studies of subseabed disposal; and (6) systems studies of waste transportation

  10. Repeatability of Cryogenic Multilayer Insulation

    Science.gov (United States)

    Johnson, W. L.; Vanderlaan, M.; Wood, J. J.; Rhys, N. O.; Guo, W.; Van Sciver, S.; Chato, D. J.

    2017-12-01

    Due to the variety of requirements across aerospace platforms, and one off projects, the repeatability of cryogenic multilayer insulation (MLI) has never been fully established. The objective of this test program is to provide a more basic understanding of the thermal performance repeatability of MLI systems that are applicable to large scale tanks. There are several different types of repeatability that can be accounted for: these include repeatability between identical blankets, repeatability of installation of the same blanket, and repeatability of a test apparatus. The focus of the work in this report is on the first two types of repeatability. Statistically, repeatability can mean many different things. In simplest form, it refers to the range of performance that a population exhibits and the average of the population. However, as more and more identical components are made (i.e. the population of concern grows), the simple range morphs into a standard deviation from an average performance. Initial repeatability testing on MLI blankets has been completed at Florida State University. Repeatability of five Glenn Research Center (GRC) provided coupons with 25 layers was shown to be +/- 8.4% whereas repeatability of repeatedly installing a single coupon was shown to be +/- 8.0%. A second group of 10 coupons has been fabricated by Yetispace and tested by Florida State University, the repeatability between coupons has been shown to be +/- 15-25%. Based on detailed statistical analysis, the data has been shown to be statistically significant.

  11. One-Session Exposure Treatment for Social Anxiety with Specific Fear of Public Speaking

    Science.gov (United States)

    Hindo, Cindy S.; Gonzalez-Prendes, A. Antonio

    2011-01-01

    Objectives: This pilot study evaluated the effectiveness of one-session, exposure-based therapy, to treat social anxiety disorder (SAD) with specific fear of public speaking. Methods: A quasi-experimental pre-posttest design with repeated measures-within-subject Analysis of Variance and paired sample t-tests was used to compare pretest, posttest…

  12. Effects of an Intensive Resistant Training Sessions and Green Tea

    Directory of Open Access Journals (Sweden)

    Mohammad Esmaeil Afzalpour

    2014-03-01

    Full Text Available Background: Intensive and acute exercise trainings may induce oxidative stress, but antioxidant supplements may attenuate its degenerative consequences. The aim of this research was to examine the effect of green tea supplementation on the oxidative stress indices after an intensive resistance training session. Materials and Methods: 40 non-athletes (without regular physical activity women were randomly divided into 4 equal (n=10 groups including green tea supplementation, green tea supplementation plus resistance training, resistance training, and control groups. After supplementation period (600 mg/day, 14 days, resistance training and green tea supplementation plus resistance training groups performed an intensive resistance training session at 75-85 % of one repetition maximum. The malondialdehyde and total thiol were measured as oxidative stress indices. Data were analyzed by using of repeated measure ANOVA and LSD tests at p<0.056T. Results: Results showed that after 14 days of green tea consumption, malondialdehyde significantly decreased in green tea supplementation (p=0.03 and green tea supplementation plus resistance training (p=0.01 groups, while total thiol increased significantly (p=0.01 in two green tea supplementation groups. However, an intensive resistance training session increased malondialdehyde (p=0.01 without any significantly changes in total thiol (p=0.426T. Conclusion: It seems that green tea supplementation can inhibit exercise-induced protein and lipid oxidation in non-athletes women via enhancement of antioxidant defense system of the body6T.6T

  13. Within-session spacing improves delayed recall in children.

    Science.gov (United States)

    Zigterman, Jessica R; Simone, Patricia M; Bell, Matthew C

    2015-01-01

    Multiple retrievals of a memory over a spaced manner improve long-term memory performance in infants, children, younger and older adults; however, few studies have examined spacing effects with young school-age children. To expand the understanding of the spacing benefit in children, the current study presented weakly associated English word-pairs to children aged 7-11 and cued their recall two times immediately (massed), after a delay of 5 or 10 items (spaced) or not at all (control). After this encoding session with or without two retrievals, participants were tested two times for memory of all word-pairs: immediately and 30 minutes after the encoding session. Multiple retrievals significantly improved memory on the tests. However, words repeated in a spaced design were remembered at higher rates than those that were massed, while gap size between repetitions (5 or 10) did not differentially impact performance. The data show that a within-session spacing strategy can benefit children's ability to remember word-pairs after 30 minutes. Thus, asking students to recall what they have learned within a lesson is a technique that can be used in a classroom to improve long-term recall.

  14. The Physics session at the ATLAS overview week

    CERN Multimedia

    Takai, H.

    The Physics session at the ATLAS overview week at Clermont-Ferrand will be certainly remembered by the presentation of Blaise Pascal's historical experiment repeat. And why not? He is the local hero and by the looks of his primitive measurements it does take a lot of guts to explain his results on the basis of air columns. He was also lucky that he did not have to simulate his results on modern day computers but used the Pascaline. Certainly a man ahead of his time. Of course that wasn't all. Surrounded by a chain of (luckily) extinct volcanoes, rolling hills, and superb views, Clermont-Ferrand provided the perfect backdrop for the physics discussions. It was once more seen that the physics of ATLAS is diverse and that it is healthy and doing well. Many people contributed to the success of the session. Fabiola started the session precisely at 14:00 with a summary of the most recent activities from the physics coordination. Somehow what got stuck in my mind was the very positive statistics on how many prese...

  15. Secure Execution of Distributed Session Programs

    Directory of Open Access Journals (Sweden)

    Nuno Alves

    2011-10-01

    Full Text Available The development of the SJ Framework for session-based distributed programming is part of recent and ongoing research into integrating session types and practical, real-world programming languages. SJ programs featuring session types (protocols are statically checked by the SJ compiler to verify the key property of communication safety, meaning that parties engaged in a session only communicate messages, including higher-order communications via session delegation, that are compatible with the message types expected by the recipient. This paper presents current work on security aspects of the SJ Framework. Firstly, we discuss our implementation experience from improving the SJ Runtime platform with security measures to protect and augment communication safety at runtime. We implement a transport component for secure session execution that uses a modified TLS connection with authentication based on the Secure Remote Password (SRP protocol. The key technical point is the delicate treatment of secure session delegation to counter a previous vulnerability. We find that the modular design of the SJ Runtime, based on the notion of an Abstract Transport for session communication, supports rapid extension to utilise additional transports whilst separating this concern from the application-level session programming task. In the second part of this abstract, we formally prove the target security properties by modelling the extended SJ delegation protocols in the pi-calculus.

  16. Oral biopsy: Oral pathologist′s perspective

    Directory of Open Access Journals (Sweden)

    K L Kumaraswamy

    2012-01-01

    Full Text Available Many oral lesions may need to be diagnosed by removing a sample of tissue from the oral cavity. Biopsy is widely used in the medical field, but the practice is not quite widespread in dental practice. As oral pathologists, we have found many artifacts in the tissue specimen because of poor biopsy technique or handling, which has led to diagnostic pitfalls and misery to both the patient and the clinician. This article aims at alerting the clinicians about the clinical faults arising preoperatively, intraoperatively and postoperatively while dealing with oral biopsy that may affect the histological assessment of the tissue and, therefore, the diagnosis. It also reviews the different techniques, precautions and special considerations necessary for specific lesions.

  17. Isolate pulmonary nodule. CT-guided biopsy

    International Nuclear Information System (INIS)

    Bruneton, J.N.; Ettore, F.; Rogopoulos, A.; Geoffray, A.; Balu-Maestro, C.; Le Houcq, M.

    1989-01-01

    Transparietal CT-guided biopsy location can be successfully performed for isolate pulmonary nodules, defined as lesions with a maximal diameter of 3 cm, without any other parenchymal or mediastinal abnormality. A 21 G needle has been used according to an identical protocole in 64 cases (10 benign, 54 malignant). The biopsy was successful in 77.7% of the malignant cases. In relation to the diameter of the nodules, biopsy was successful in 66.7% of the nodules smaller than 2 cm and in 76% of the nodules ranging from 2 to 3 cm. The complications observed were rare (1 case of pneumothorax requiring drainage, 9 cases of pneumothorax without clinical signs and simply followed up, 4 cases of minor hemoptysis requiring no treatment and 5 cases of hematomas smaller than 5 cm on CT) [fr

  18. Comparative study of decomposable and indecomposable biopsy needle in lung puncture biopsy

    International Nuclear Information System (INIS)

    Wang Bo; Sheng Zhanxin; Wen Yamin; Zhang Liping; Wen Zongqiu

    2007-01-01

    Objective: To contrast the clinical practice characteristics with decomposable and indecomposable biopsy needle in the CT-guided lung puncture biopsy. Methods: 50 patients with lung tumour carried on puncture biopsy under the CT guidance were divided in two groups randomly: Group A (25 examples): using the indecomposable BioPinceTM biopsy needle; Group B(25 examples): using the decomposable Precisa or Vitesse biopsy needle. The puncture biopsy organization quantity, the first time puncture success rate, the pathological diagnosis result and the incidence of puncture complication were compared in two groups. Results: More striped structures were gained obviously in group A than in group B: 24/25 and 11/25 respectively (P>0.05), The pathological diagnosis 'serious extrusion amoebocyte and nature undetermined' only occurred in group B. But the first time puncture success rate was lower in group A than in B: 52%(13/25) and 80%(20/25) respectively (P>0.05), The incidence of hemorrhage and pneumothorax in group A was higher slightly: 84% and 72%, 16% and 4% respectively (P>0.05). Conclusion: The indecomposable needle (BioPinceTM) was better in lung puncture biopsy, but the lower first time puncture success rate also increases the risk of operation and complication in some degree because of the structure of the needle. On the contrary, decomposable needle (the Precisa or the Vitesse) was not the best choice in lung puncture biopsy. But it had the original superiority, especially regarding the special patient such as patient with small tumour, thin thoracic wall, bad physique for its nimble operation. It is essential for us to use the two different types of biopsy needle rationally to enhance the level of CT-guided lung puncture biopsy. (authors)

  19. 78 FR 65594 - Vehicular Repeaters

    Science.gov (United States)

    2013-11-01

    ... coordinators estimate the effect on coordination fees? Does the supposed benefit that mobile repeater stations... allow the licensing and operation of vehicular repeater systems and other mobile repeaters by public... email: [email protected] or phone: 202-418- 0530 or TTY: 202-418-0432. For detailed instructions for...

  20. Performing bone marrow biopsies with or without sedation: a comparison.

    Science.gov (United States)

    Giannoutsos, I; Grech, H; Maboreke, T; Morgenstern, G

    2004-06-01

    Although intravenous sedation (ISED) in addition to a local anaesthetic (LA) is commonly used in the performance of a bone marrow aspirate and trephine (BMAT), it is not clear under what circumstances and in which way sedation may be most beneficial. In this study, information was gathered using a questionnaire, from 112 patients shortly after undergoing BMAT; the duration of the procedures and the length of the biopsy cores were measured and any complications noted. Most patients (68%) chose to receive LA only, and almost all (74/76) were happy with their decision. Patients who received sedation gave lower pain scores than patients receiving LA only (1 vs. 3) and were found to have lower levels of apprehension at the thought of having a repeat procedure. Patients having a repeat BMAT showed a slightly increased preference for having sedation compared with patients who were undergoing it for the first time. There is some concern that guidelines regarding the use of ISED for procedures other than BMAT are not always adhered to, and current practice may be best revealed by a large-scale audit of sedation practice for the performance of BMAT. Patients should be given the choice of having ISED if the appropriate resources are available, but in most cases the additional small risk of receiving sedation can be avoided.

  1. Endobronkial ultralydsskanning af mediastinum med biopsi

    DEFF Research Database (Denmark)

    Siemsen, Mette; Steffensen, Ida E; Iversen, Martin

    2010-01-01

    Endobronchial ultrasound (EBUS) is a minimally invasive diagnostic modality, by which it is possible to visualize and do biopsy of structures adjacent to the trachea and the central bronchial system. EBUS is mostly used for staging of lung cancer patients, but EBUS is now used worldwide as a diag......Endobronchial ultrasound (EBUS) is a minimally invasive diagnostic modality, by which it is possible to visualize and do biopsy of structures adjacent to the trachea and the central bronchial system. EBUS is mostly used for staging of lung cancer patients, but EBUS is now used worldwide...

  2. Liver biopsy in liver patients with coagulopathy

    DEFF Research Database (Denmark)

    Ott, P.; Gronbaek, H.; Clausen, M.R.

    2008-01-01

    The risk of severe bleeding after liver biopsy is estimated to be 1:12,000 in patients with near normal coagulation (INR 60 billion /l). Beyond these limits, the risk is higher, but still uncertain. The Danish guidelines require INR > 1.5, platelet count ... and normal APTT. In some instances the risk of not knowing the histology is so high that a biopsy is considered even with a more disturbed coagulation. Vitamin K, freshly frozen plasma and recombinant activated factor VII may reduce the risk of bleeding in specific situations, but no firm recommendations can...

  3. Ultrasound-guided biopsy and drainage

    International Nuclear Information System (INIS)

    Ott, R.C.; Wellauer, J.

    1985-01-01

    This book discusses the ultrasound (US) biopsy techniques, cytology, histology, and physics. The emphasis is on use of US guidance, as the authors find that virtually all lesions are visible at US scanning and they thus save valuable time on the computer tomographic scanner. The authors present in great detail their considerable work in designing needles that are readily visible at US scanning and can also collect good cytologic and histologic material. Biopsy techniques are discussed separately for each organ system. The accuracy of these techniques in over 3,000 of the author's cases is presented

  4. Dermatofibrosarcoma protuberans diagnosed by a single biopsy

    Directory of Open Access Journals (Sweden)

    Kristian Bakke Arvesen

    2012-07-01

    Full Text Available This brief report is about a 9 year old girl presenting with a 2.5 cm circular blue to violet discoloration on the anterolateral upper left thigh. The first biopsy taken revealed the diagnosis dermatofibrosarcoma protuberans. The patient underwent surgery at a specialized sarcoma center with post operative histology showing free wide resection margin. Preoperative chest x-ray showed no sign of metastasis. This brief report emphasizes the significance of the use of biopsy when cutaneous elements look suspicious and diagnosis is unclear.

  5. Sentinel lymph node biopsy in oral cancer

    DEFF Research Database (Denmark)

    Thomsen, Jørn Bo; Sørensen, Jens Ahm; Grupe, Peter

    2005-01-01

    PURPOSE: To validate lymphatic mapping combined with sentinel lymph node biopsy as a staging procedure, and to evaluate the possible clinical implications of added oblique lymphoscintigraphy and/or tomography and test the intra- and interobserver reproducibility of lymphoscintigraphy. MATERIAL......: Eleven (28%) patients were upstaged. The sentinel lymph node identification rate was 97.5%. Sentinel lymph node biopsy significantly differentiated between patients with or without lymph node metastasis (P = 0.001). Lymphatic mapping revealed 124 hotspots and 144 hot lymph nodes were removed by sentinel...

  6. The effect of repeated periods of speed endurance training on performance, running economy, and muscle adaptations.

    Science.gov (United States)

    Skovgaard, C; Almquist, N W; Bangsbo, J

    2018-02-01

    The effect of repeated intense training interventions was investigated in eight trained male runners (maximum oxygen uptake [VO 2 -max]: 59.3±3.2 mL/kg/min, mean±SD) who performed 10 speed endurance training (SET; repeated 30-seconds "all-out" bouts) and 10 aerobic moderate-intensity training sessions during two 40-day periods (P1 and P2) separated by ~80 days of habitual training. Before and after both P1 and P2, subjects completed an incremental test to exhaustion to determine VO 2 -max and a repeated running test at 90% vVO 2 -max to exhaustion (RRT) to determine short-term endurance capacity. In addition, running economy (RE) was measured at 60% vVO 2 -max (11.9±0.5 km/h) and v10-km (14.3±0.9 km/h), a 10-km track-running test was performed, and a biopsy from m. vastus lateralis was collected. 10-km performance and VO 2 -max (mL/min) were the same prior to P1 and P2, whereas RE was better (P<.05) before P2 than before P1. During P1 and P2, 10-km performance (2.9% and 2.3%), VO 2 -max (2.1% and 2.6%), and RE (1.9% and 1.8% at 60% vVO 2 -max; 1.6% and 2.0% at v10-km) improved (P<.05) to the same extent, respectively. Performance in RRT was 20% better (P<.05) after compared to before P2, with no change in P1. No changes in muscle expression of Na + ,K + -ATPase α1, α2 and β1, NHE1, SERCA1 and SERCA2, actin, and CaMKII were found during neither P1 nor P2. Thus, the present study demonstrates that a second period of intense training leads to improved short-term performance and further improved RE, whereas 10-km performance and VO 2 -max improve to the same extent as during the first period. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Does imprint cytology improve the accuracy of transrectal prostate needle biopsy?

    Science.gov (United States)

    Sayar, Hamide; Bulut, Burak Besir; Bahar, Abdulkadir Yasir; Bahar, Mustafa Remzi; Seringec, Nurten; Resim, Sefa; Çıralık, Harun

    2015-02-01

    To evaluate the accuracy of imprint cytology of core needle biopsy specimens in the diagnosis of prostate cancer. Between December 24, 2011 and May 9, 2013, patients with an abnormal DRE and/or serum PSA level of >2.5 ng/mL underwent transrectal prostate needle biopsy. Samples with positive imprint cytology but negative initial histologic exam underwent repeat sectioning and histological examination. 1,262 transrectal prostate needle biopsy specimens were evaluated from 100 patients. Malignant imprint cytology was found in 236 specimens (18.7%), 197 (15.6%) of which were confirmed by histologic examination, giving an initial 3.1% (n = 39) rate of discrepant results by imprint cytology. Upon repeat sectioning and histologic examination of these 39 biopsy samples, 14 (1.1% of the original specimens) were then diagnosed as malignant, 3 (0.2%) as atypical small acinar proliferation (ASAP), and 5 (0.4%) as high-grade prostatic intraepithelial neoplasia (HGPIN). Overall, 964 (76.4%) specimens were negative for malignancy by imprint cytology. Seven (0.6%) specimens were benign by cytology but malignant cells were found on histological evaluation. On imprint cytology examination, nonmalignant but abnormal findings were seen in 62 specimens (4.9%). These were all due to benign processes. After reexamination, the accuracy, sensitivity, specificity, positive predictive value, negative predictive value, false-positive rate, false-negative rate of imprint preparations were 98.1, 96.9, 98.4, 92.8, 99.3, 1.6, 3.1%, respectively. Imprint cytology is valuable tool for evaluating TRUS-guided core needle biopsy specimens from the prostate. Use of imprint cytology in combination with histopathology increases diagnostic accuracy when compared with histopathologic assessment alone. © 2014 Wiley Periodicals, Inc.

  8. CT-guided biopsy of pulmonary lesions : a comparison of diagnostic accuracy and complication rate between automated gun biopsy and fine needle aspiration biopsy

    International Nuclear Information System (INIS)

    Kim, Keon Woo; Kang, Duk Sik

    1998-01-01

    The purpose of this study is to compare the efficacy and safety of CT-guided automated gun biopsy with those of fine needle aspiration biopsy of pulmonary lesions. Under CT guidance, we performed automated gu biopsies in 115 cases of 109 patients and fine needle aspiration biopsies in 119 cases of 108 patients with pulmonary lesions. Between the two methods, we compared the diagnostic rate, diagnostic accuracy and frequency of compilations according to the depth and diameter of pulmonary lesions. The overall diagnostic rates of automated gun biopsy and fine needle aspiration biopsy were 76.5 % (88/115) and 64.7 % (77/119) respectively. There was a significant statistical difference (p=0.048), especially in the case of malignant lesions less than 3 cm (p=0.027) and more than 6 cm in maximal diameter (p=0.008), and in the lesions located from 1 cm to less than 3 cm from the pleural (p=0.030), as seen on CT. There was no significant statistical difference in the frequency of complications. Automated gun biopsy of pulmonary lesions under CT guidance is safe, with complications rate comparable to those of fine needle aspiration biopsy. A higher overall diagnostic rate can be achieved by automated gun biopsy than by fine needle aspiration biopsy. For the diagnosis of pulmonary lesions under CT guidance, automated gun biopsy is therefore a more useful procedure than fine needle aspiration biopsy. (author). 24 refs., 3 tabs

  9. Transjugular liver biopsy : the efficacy of quick-core biopsy needle system

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Gyoo Sik; Ahn, Byung Kwon; Lee, Sang Ouk; Chang, Hee Kyong; Oh, Kyung Seung; Huh, Jin Do; Joh, Young Duk [Kosin Medical College, Pusan (Korea, Republic of)

    1998-02-01

    To evaluate the efficacy of the Quick-Core biopsy needle system in performing transjugular liver biopsy. Between December 1995 and June 1997, eight patients underwent transjugular liver biopsy involving use of the Quick-Core biopsy needle system; the conditions involved were coagulopathy (n=4), thrombocytopenia (n=3), and ascites (n=1). Via the right internal jugular vein, the right hepatic vein was selectively catheterized with a 7-F transjugular guiding catheter, and a14-guage stiffening cannula was then inserted through this catheter; to obtain core tissue, a Quick-Core needle was then advanced into the liver parenchyma through the catheter-cannula combination. Eighteen- and 19-guage needles were used in three and five patients, respectively; specimen size, adequacy of the biopsy specimen and histologic diagnosis were determined, and complications were recorded. Biopsy was successful in all patients. The mean length of the specimen was 1.4 cm (1.0 - 1.8 cm), and all were adequate for pathologic examinations ; specific diagnosis was determined in all patients. There were two malignant neoplasms, two cases of veno-occlusive disease, and one case each of cirrhosis, fulminant hepatitis, Banti syndrome and Budd-Chiari syndrome. One patient complained of neck pain after the procedure, but no serious procedural complications were noted. Our preliminary study shows that the Quick-Core biopsy needle system is safe and provides adequate core tissues with high diagnostic yields. (author). 23 refs., 1 tab., 3 figs.

  10. Transjugular liver biopsy : the efficacy of quick-core biopsy needle system

    International Nuclear Information System (INIS)

    Jung, Gyoo Sik; Ahn, Byung Kwon; Lee, Sang Ouk; Chang, Hee Kyong; Oh, Kyung Seung; Huh, Jin Do; Joh, Young Duk

    1998-01-01

    To evaluate the efficacy of the Quick-Core biopsy needle system in performing transjugular liver biopsy. Between December 1995 and June 1997, eight patients underwent transjugular liver biopsy involving use of the Quick-Core biopsy needle system; the conditions involved were coagulopathy (n=4), thrombocytopenia (n=3), and ascites (n=1). Via the right internal jugular vein, the right hepatic vein was selectively catheterized with a 7-F transjugular guiding catheter, and a14-guage stiffening cannula was then inserted through this catheter; to obtain core tissue, a Quick-Core needle was then advanced into the liver parenchyma through the catheter-cannula combination. Eighteen- and 19-guage needles were used in three and five patients, respectively; specimen size, adequacy of the biopsy specimen and histologic diagnosis were determined, and complications were recorded. Biopsy was successful in all patients. The mean length of the specimen was 1.4 cm (1.0 - 1.8 cm), and all were adequate for pathologic examinations ; specific diagnosis was determined in all patients. There were two malignant neoplasms, two cases of veno-occlusive disease, and one case each of cirrhosis, fulminant hepatitis, Banti syndrome and Budd-Chiari syndrome. One patient complained of neck pain after the procedure, but no serious procedural complications were noted. Our preliminary study shows that the Quick-Core biopsy needle system is safe and provides adequate core tissues with high diagnostic yields. (author). 23 refs., 1 tab., 3 figs

  11. Undergraduate Researchers and the Poster Session

    Science.gov (United States)

    Johnson, Gail; Green, Raymond

    2007-01-01

    Undergraduates presented original research in classroom poster sessions open to students, faculty, and friends. We assessed the reaction of the students to the experience and their reported change in their interest in presenting at conferences. Students enjoyed the poster session experience and indicated they preferred this method over other…

  12. Multiparty session types as coherence proofs

    DEFF Research Database (Denmark)

    Carbone, Marco; Montesi, Fabrizio; Schürmann, Carsten

    2017-01-01

    We propose a Curry–Howard correspondence between a language for programming multiparty sessions and a generalisation of Classical Linear Logic (CLL). In this framework, propositions correspond to the local behaviour of a participant in a multiparty session type, proofs to processes, and proof nor...

  13. Summary of southeastern group breakout sessions

    Science.gov (United States)

    Bob Ford; Charles P. Nicholson

    1993-01-01

    The breakout sessions held by the southeastern representatives at the Partners In Flight meeting in Colorado were extremely well attended Most states were represented, as well as several federal agencies (including USFS, USFWS, TVA, EPA), and non-government organizations. Two sessions were held, one to discuss a strategy of management by...

  14. Summary of the session on other effects

    International Nuclear Information System (INIS)

    Chao, A.

    1997-07-01

    The theme of this workshop is to discuss the effects of foreign particles on the native beam in a storage ring. This paper summarizes the session on effects not covered in sessions on fast ion instability, electron cloud instability, and cures. The topics discussed are the beam, the foreign particle, how are foreign particles trapped, and how do foreign particles and beam couple

  15. Ann Arbor Session I: Breaking Ground.

    Science.gov (United States)

    Music Educators Journal, 1979

    1979-01-01

    Summarizes the first session of the National Symposium on the Applications of Psychology to the Teaching and Learning of Music held at Ann Arbor from October 30 to November 2, 1978. Sessions concerned auditory perception, motor learning, child development, memory and information processing, and affect and motivation. (SJL)

  16. BILATERAL SINGLE SESSION URETEROSCOPY FOR URETERAL ...

    African Journals Online (AJOL)

    Objectives: To determine the feasibility, safety and success rate of bilateral single session rigid retrograde ureteroscopy (URS) for bilateral ureteral calculi. Patients and Methods: Thirty-five patients underwent bilateral single session ureteroscopic calculus removal. Results: Out of 70 renal units in 35 patients treated, ...

  17. Targeted MRI-guided prostate biopsy: are two biopsy cores per MRI-lesion required?

    Energy Technology Data Exchange (ETDEWEB)

    Schimmoeller, L.; Quentin, M.; Blondin, D.; Dietzel, F.; Schleich, C.; Thomas, C.; Antoch, G. [University Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Dusseldorf (Germany); Hiester, A.; Rabenalt, R.; Albers, P.; Arsov, C. [University Dusseldorf, Medical Faculty, Department of Urology, Dusseldorf (Germany); Gabbert, H.E. [University Dusseldorf, Medical Faculty, Department of Pathology, Dusseldorf (Germany)

    2016-11-15

    This study evaluates the feasibility of performing less than two core biopsies per MRI-lesion when performing targeted MR-guided in-bore prostate biopsy. Retrospectively evaluated were 1545 biopsy cores of 774 intraprostatic lesions (two cores per lesion) in 290 patients (66 ± 7.8 years; median PSA 8.2 ng/ml) regarding prostate cancer (PCa) detection, Gleason score, and tumor infiltration of the first (FBC) compared to the second biopsy core (SBC). Biopsies were acquired under in-bore MR-guidance. For the biopsy cores, 491 were PCa positive, 239 of 774 (31 %) were FBC and 252 of 771 (33 %) were SBC (p = 0.4). Patient PCa detection rate based on the FBC vs. SBC were 46 % vs. 48 % (p = 0.6). For clinically significant PCa (Gleason score ≥4 + 3 = 7) the detection rate was 18 % for both, FBC and SBC (p = 0.9). Six hundred and eighty-seven SBC (89 %) showed no histologic difference. On the lesion level, 40 SBC detected PCa with negative FBC (7.5 %). Twenty SBC showed a Gleason upgrade from 3 + 3 = 6 to ≥3 + 4 = 7 (2.6 %) and 4 to ≥4 + 3 = 7 (0.5 %). The benefit of a second targeted biopsy core per suspicious MRI-lesion is likely minor, especially regarding PCa detection rate and significant Gleason upgrading. Therefore, a further reduction of biopsy cores is reasonable when performing a targeted MR-guided in-bore prostate biopsy. (orig.)

  18. Stereotactic core biopsy: Comparison of 11 gauge with 8 gauge vacuum assisted breast biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Venkataraman, Shambhavi, E-mail: svenkata@bidmc.harvard.edu [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215 (United States); Dialani, Vandana [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215 (United States); Gilmore, Hannah L. [Department of Pathology, UH Case Medical Center, 11100 Euclid Ave, Cleveland, OH 44106 (United States); Mehta, Tejas S. [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215 (United States)

    2012-10-15

    Purpose: The compare the performance and ability to obtain a correct diagnosis on needle biopsy between 11 gauge and 8 gauge vacuum assisted biopsy devices. Materials and methods: Hospital records of all consecutive stereotactic core biopsies performed over five years were retrospectively reviewed in compliance Health Insurance Portability and Accountability Act (HIPPA) policy and with approval from the hospital institutional review board (IRB). Pathology from core biopsy was compared with surgical pathology and/or imaging follow-up. A histological underestimation was defined if the surgical excision yielded a higher grade on pathology which changed management. Results: 828 needle core biopsies (47.5%, 393/828 with 11 gauge and 52.5%, 435/828 with 8 gauge) yielded 471 benign, 153 high risk and 204 malignant lesions. 30/193 (15.5%) 11 gauge lesions and 16/185 (8.6%) 8 gauge lesions demonstrated higher grade pathology on surgical excision. The difference in the rates of the number of correct diagnoses on core needle biopsy between 11 gauge (363/393, 92.4%) and 8 gauge (419/435, 96.3%) based on either surgical or clinical/imaging follow up and the difference in the number of discordant benign core biopsies between 11 (17/217, 7.8%) and 8 gauge (4/254, 1.6%) necessitating a surgical biopsy was significant (P = 0.013; P = 0.001). Although there were more underestimations with the 11 gauge (25/193, 13.0%) than 8 gauge (15/185, 8.1%) needle, this was not significant. Conclusion: Our study demonstrates improved performance and increased diagnostic ability of 8 gauge needle over 11 gauge in obtaining a correct diagnosis on needle biopsy.

  19. Targeted MRI-guided prostate biopsy: are two biopsy cores per MRI-lesion required?

    International Nuclear Information System (INIS)

    Schimmoeller, L.; Quentin, M.; Blondin, D.; Dietzel, F.; Schleich, C.; Thomas, C.; Antoch, G.; Hiester, A.; Rabenalt, R.; Albers, P.; Arsov, C.; Gabbert, H.E.

    2016-01-01

    This study evaluates the feasibility of performing less than two core biopsies per MRI-lesion when performing targeted MR-guided in-bore prostate biopsy. Retrospectively evaluated were 1545 biopsy cores of 774 intraprostatic lesions (two cores per lesion) in 290 patients (66 ± 7.8 years; median PSA 8.2 ng/ml) regarding prostate cancer (PCa) detection, Gleason score, and tumor infiltration of the first (FBC) compared to the second biopsy core (SBC). Biopsies were acquired under in-bore MR-guidance. For the biopsy cores, 491 were PCa positive, 239 of 774 (31 %) were FBC and 252 of 771 (33 %) were SBC (p = 0.4). Patient PCa detection rate based on the FBC vs. SBC were 46 % vs. 48 % (p = 0.6). For clinically significant PCa (Gleason score ≥4 + 3 = 7) the detection rate was 18 % for both, FBC and SBC (p = 0.9). Six hundred and eighty-seven SBC (89 %) showed no histologic difference. On the lesion level, 40 SBC detected PCa with negative FBC (7.5 %). Twenty SBC showed a Gleason upgrade from 3 + 3 = 6 to ≥3 + 4 = 7 (2.6 %) and 4 to ≥4 + 3 = 7 (0.5 %). The benefit of a second targeted biopsy core per suspicious MRI-lesion is likely minor, especially regarding PCa detection rate and significant Gleason upgrading. Therefore, a further reduction of biopsy cores is reasonable when performing a targeted MR-guided in-bore prostate biopsy. (orig.)

  20. Summary of Technical Sessions - Summary and Recommendations

    International Nuclear Information System (INIS)

    2013-01-01

    Technical Session 1 - Development achievements of BEPU methods and State of the Art: The objective of this session was to present the different approaches dealing with Best Estimate codes and uncertainties evaluations. Existing methods were summarized and different papers were focused on specific methods stressing their bases, peculiarities, advantages and limitations. As a result of the session a picture of the current State of the Art was obtained. The session comprised six papers. Technical Session 2 - International comparative activities: This session had as a main objective to review the activities launched in the past and present from the NEA in connection with BEPU methods, with focus on the applicability of conclusions derived from former benchmarks like UMS, the main outcomes of the recently finished BEMUSE project, and the objectives and relevance of UAM and PREMIUM projects. The session comprised four papers. Technical Session 3 - Applications: Licensing, safety analysis support, regulatory body views and industry activities: This session focused on the application of current methods in safety analyses. Contributions from industry, technical safety organizations and regulatory bodies were provided. As a result, a view of the penetration of BEPU methods in current safety analyses was obtained, as well as an indication of the evolution in the near future. Elements such as licensing practices, assessment process, etc. were considered. The session comprised nine papers. Technical Session 4. BEPU methods extension to new fields The session addressed the extension of BEPU methods beyond their current use. By now such methods are mainly applied to classic deterministic environment but it is believed that their benefits could be extended to other fields. Seven papers were presented in the session dealing with subjects that fit in the objectives established in the workshop programme. The papers cover areas like: extension to CFD, quantification of global safety

  1. Using session types as an effect system

    Directory of Open Access Journals (Sweden)

    Dominic Orchard

    2016-02-01

    Full Text Available Side effects are a core part of practical programming. However, they are often hard to reason about, particularly in a concurrent setting. We propose a foundation for reasoning about concurrent side effects using sessions. Primarily, we show that session types are expressive enough to encode an effect system for stateful processes. This is formalised via an effect-preserving encoding of a simple imperative language with an effect system into the pi-calculus with session primitives and session types (into which we encode effect specifications. This result goes towards showing a connection between the expressivity of session types and effect systems. We briefly discuss how the encoding could be extended and applied to reason about and control concurrent side effects.

  2. Core biopsies of the breast: Diagnostic pitfalls

    Directory of Open Access Journals (Sweden)

    Megha Joshi

    2011-01-01

    Full Text Available The incidence of breast cancer is increasing worldwide. In this review article, the authors compare and contrast the incidence of breast cancer, and the inherent differences in the United States (US and India in screening techniques used for diagnosing breast cancer. In spite of these differences, core biopsies of the breast are common for diagnosis of breast cancer in both countries. The authors describe "Best Practices" in the reporting and processing of core biopsies and in the analysis of estrogen receptor (ER, progesterone receptor (PR, and human epidermal growth factor Receptor 2 (Her2/neu. The pitfalls in the diagnosis of fibroepithelial lesions of the breast on core biopsy are discussed, as also the significance of pseudoangiomatous stromal hyperplasia of the breast (PASH is discussed in core biopsy. In this review, the management and diagnosis of flat epithelial atypia and radiation atypia are elaborated and the use of immunohistochemistry (IHC in papillary lesions, phyllodes tumor, and complex sclerosing lesions (radial scars is illustrated. Rarer lesions such as mucinous and histiocytoid carcinoma are also discussed.

  3. Ultrasound- and MRI-Guided Prostate Biopsy

    Science.gov (United States)

    ... assistance of a nurse and an MR imaging technologist. As with the ultrasound procedure, you may receive antibiotics, sedatives and pain medication before the biopsy. The MRI-guided procedure may use contrast ... A nurse or technologist will insert an intravenous (IV) catheter into a ...

  4. Liver biopsy — the current view?

    African Journals Online (AJOL)

    needles, or the more recent cutting-core automated or semi-automated needles. These may be single units, or part of gun-type system with disposable needles. The pathologist's requirements of the specimen depend on whether diffuse disease or focal lesions are biopsied. The ideal tissue core for diffuse disease should be ...

  5. Protective Capnothorax During Transthoracic Needle Biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Kavanagh, John, E-mail: jokavana@tcd.ie; Siemienowicz, Miranda L.; Lyen, Stephen; Kandel, Sonja; Rogalla, Patrik [University of Toronto, Division of Cardiothoracic Imaging, Joint Department of Medical Imaging, University Health Network and Mount Sinai Hospital (Canada)

    2017-04-15

    PurposeTransthoracic needle biopsy (TTNB) is an established procedure in the management of pulmonary nodules. The most common complications are directly related to crossing the lung or visceral pleura during the biopsy. In this study, we describe the use of carbon dioxide instead of room air to create a protective “capnothorax” during TTNB.Materials and MethodsFive patients underwent creation of a capnothorax during TTNB. Parameters recorded were location and size of target, distance from pleura, length of procedure, volume of carbon dioxide, periprocedural complications and biopsy result.ResultsInduction of capnothorax was successful in all cases. In two patients, a continuous infusion of carbon dioxide was required to maintain an adequate volume of intrapleural gas. In two patients, the carbon dioxide resolved spontaneously and in the remaining patients it was aspirated at the end of the procedure. All biopsies were diagnostic with no periprocedural or postprocedural complications.ConclusionThis study suggests that protective iatrogenic capnothorax is a safe and effective technique during TTNB. The intrinsic properties and availability of carbon dioxide make it an attractive alternative to room air.

  6. Unusual presentation and inconclusive biopsy render fibroadenoma ...

    African Journals Online (AJOL)

    Two young, nonlactating, nulliparous women presented with acutely painful breast masses. Sonographic features showed mixed echogenic masses. Core biopsies were not diagnostic, and surgical excision revealed infarcted fibroadenomas in both cases. Although fibroadenomas are common, they do not commonly infarct, ...

  7. Effects of combined liver and udder biopsying on the acute phase response of dairy cows with experimentally induced E. coli mastitis

    DEFF Research Database (Denmark)

    Khatun, Momena; Sørensen, Peter; Ingvartsen, Klaus Lønne

    2013-01-01

    A minimally invasive biopsy technique was evaluated for udder tissue collection in dairy cows with Escherichia coli mastitis. Meanwhile, the effect of taking repeated liver and udder biopsies on the systemic and local acute phase response (APR) of the dairy cows was investigated during the disease...... the systemic and local APR in dairy cows during E. coli mastitis, if the timing of biopsying and other types of sampling is planned accordingly....... The cows were divided into a biopsy group (B) (n = 16) and a no-biopsy group (NB) (n = 16) and were sampled in the acute disease stage and in the recovery stage. The cows’ pre-disease period served as a control period for establishing baseline values for the investigated parameters. A total of 32 Holstein...

  8. Repeated causal decision making.

    Science.gov (United States)

    Hagmayer, York; Meder, Björn

    2013-01-01

    Many of our decisions refer to actions that have a causal impact on the external environment. Such actions may not only allow for the mere learning of expected values or utilities but also for acquiring knowledge about the causal structure of our world. We used a repeated decision-making paradigm to examine what kind of knowledge people acquire in such situations and how they use their knowledge to adapt to changes in the decision context. Our studies show that decision makers' behavior is strongly contingent on their causal beliefs and that people exploit their causal knowledge to assess the consequences of changes in the decision problem. A high consistency between hypotheses about causal structure, causally expected values, and actual choices was observed. The experiments show that (a) existing causal hypotheses guide the interpretation of decision feedback, (b) consequences of decisions are used to revise existing causal beliefs, and (c) decision makers use the experienced feedback to induce a causal model of the choice situation even when they have no initial causal hypotheses, which (d) enables them to adapt their choices to changes of the decision problem. (PsycINFO Database Record (c) 2013 APA, all rights reserved).

  9. Psychiatric disorder associated with vacuum-assisted breast biopsy clip placement: a case report

    Directory of Open Access Journals (Sweden)

    Zografos George C

    2008-10-01

    Full Text Available Abstract Introduction Vacuum-assisted breast biopsy is a minimally invasive technique that has been used increasingly in the treatment of mammographically detected, non-palpable breast lesions. Clip placement at the biopsy site is standard practice after vacuum-assisted breast biopsy. Case presentation We present the case of a 62-year-old woman with suspicious microcalcifications in her left breast. The patient was informed about vacuum-assisted breast biopsy, including clip placement. During the course of taking the patient's history, she communicated excellently, her demeanor was normal, she disclosed no intake of psychiatric medication and had not been diagnosed with any psychiatric disorders. Subsequently, the patient underwent vacuum-assisted breast biopsy (11 G under local anesthesia. A clip was placed at the biopsy site. The pathological diagnosis was of sclerosing adenosis. At the 6-month mammographic follow-up, the radiologist mentioned the existence of the metallic clip in her breast. Subsequently, the woman presented complaining about "being spied [upon] by an implanted clip in [her] breast" and repeatedly requested the removal of the clip. The patient was referred to the specialized psychiatrist of our breast unit for evaluation. The Mental State Examination found that systematized paranoid ideas of persecutory type dominated her daily routines. At the time, she believed that the implanted clip was one of several pieces of equipment being used to keep her under surveillance, the other equipment being her telephone, cameras and television. Quite surprisingly, she had never had a consultation with a mental health professional. The patient appeared depressed and her insight into her condition was impaired. The prevalent diagnosis was schizotypal disorder, whereas the differential diagnosis comprised delusional disorder of persecutory type, affective disorder with psychotic features or comorbid delusional disorder with major depression

  10. EFFICACY OF IMMUNOHISTOCHEMISTRY IN PROSTATE NEEDLE BIOPSIES

    Directory of Open Access Journals (Sweden)

    Tameem Afroz

    2016-10-01

    Full Text Available BACKGROUND Prostate needle biopsies can pose a major diagnostic challenge when it comes to differentiating adenocarcinoma and its variants from its benign mimics. In needle biopsies, when the suspicious focus is small, morphological features may not suffice to differentiate it from its morphologic mimics like atrophy, basal cell hyperplasia, reactive inflammatory changes, seminal vesicles and adenosis. Immunohistochemical marker for basal cells, p63 and prostate cancer specific marker, Alpha-Methylacyl-CoA Racemase (AMACR help in overcoming such diagnostic dilemmas. MATERIALS AND METHODS We analysed 157 prostate core needle biopsies over a period of 2 years. Routine Hematoxylin and Eosin (H and E sections and immunohistochemical markers for basal cells (p63 and prostate cancer specific marker (AMACR were used. Prospective study was done on prostate needle core biopsies. Biopsy was done under ultrasound guidance with an 18-gauge needle. Biopsy was done in patients with raised serum PSA levels for exclusion of prostate carcinoma. RESULTS Over a period of two years, 157 prostate core needle biopsies were studied. 83 were benign lesions comprising 69 benign prostatic hyperplasias, five basal cell hyperplasias, four granulomatous lesions and three showed atrophic changes. Two biopsies morphologically resembled seminal vesicles. Prostate cancer specific marker, AMACR was negative in all, but two lesions. In these two lesions, it showed weak nonspecific staining. Basal cell marker p63 showed a continuous staining pattern highlighting the basal cells in all the 69 cases of benign prostatic hyperplasia, 5 cases of basal hyperplasia showed positivity in all the hyperplastic basal cells. In the two cases of seminal vesicles, it showed intense basal cell positivity. It showed a discontinuous pattern in two of the four granulomatous lesions and showed a weak, but a continuous staining pattern in the atrophic lesions. 74 were adenocarcinomas; the predominant

  11. Effects of Post-Session Wheel Running on Within-Session Changes in Operant Responding

    Science.gov (United States)

    Aoyama, Kenjiro

    2007-01-01

    This study tested the effects of post-session wheel running on within-session changes in operant responding. Lever-pressing by six rats was reinforced by a food pellet under a continuous reinforcement (CRF) schedule in 30-min sessions. Two different flavored food pellets were used as reinforcers. In the wheel conditions, 30-min operant-sessions…

  12. Session-RPE for quantifying the load of different youth basketball training sessions.

    Science.gov (United States)

    Lupo, C; Tessitore, A; Gasperi, L; Gomez, Mar

    2017-03-01

    The aim of the study was to evaluate youth basketball training, verifying the reliability of the session-RPE method in relation to session duration (session) categories. Six male youth basketball players (age, 16.5±0.5 years; height, 195.5±6.75 cm; body mass, 93.9±10.9 kg; and body mass index, 23.6±2.8 kg.m -2 ) were monitored (HR, type and duration of workouts) during 15 (66 individual) training sessions (80±26 minutes). Edwards' HR method was used as a reference measure of internal training load (ITL); the CR-10 RPE scale was administered 30 minutes after the end of each session. The results obtained showed that all comparisons between different session durations and workout portions revealed effects in term of Edwards' ITLs except for warm-up portions. Moderate to strong relationships between Edwards' and session- RPE methods emerged for all sessions (r = .85, P sessions (r range = .79 - .95, P session durations (session-RPE to monitor the ITL, regardless of session durations and workout portions.

  13. Session-RPE for quantifying the load of different youth basketball training sessions

    Directory of Open Access Journals (Sweden)

    C Lupo

    2016-12-01

    Full Text Available The aim of the study was to evaluate youth basketball training, verifying the reliability of the session-RPE method in relation to session duration (< and ≥ 80 minutes and workout typology (reduced and high warm-up, conditioning, technical, tactical, game portions within a single session categories. Six male youth basketball players (age, 16.5±0.5 years; height, 195.5±6.75 cm; body mass, 93.9±10.9 kg; and body mass index, 23.6±2.8 kg.m-2 were monitored (HR, type and duration of workouts during 15 (66 individual training sessions (80±26 minutes. Edwards’ HR method was used as a reference measure of internal training load (ITL; the CR-10 RPE scale was administered 30 minutes after the end of each session. The results obtained showed that all comparisons between different session durations and workout portions revealed effects in term of Edwards’ ITLs except for warm-up portions. Moderate to strong relationships between Edwards’ and session- RPE methods emerged for all sessions (r = .85, P < .001, player’s sessions (r range = .79 - .95, P < .001, session durations (< 80 minutes: r = .67, P < .001; ≥ 80 minutes: r = .75, P < .001, and workout portions (r range = .78 - .89, P range = .002 - < .001. The findings indicated that coaches of youth basketball players can successfully use session-RPE to monitor the ITL, regardless of session durations and workout portions.

  14. Multi-institutional Evaluation of Upper Urinary Tract Biopsy Using Backloaded Cup Biopsy Forceps, a Nitinol Basket, and Standard Cup Biopsy Forceps.

    Science.gov (United States)

    Lama, Daniel J; Safiullah, Shoaib; Patel, Roshan M; Lee, Thomas K; Balani, Jyoti P; Zhang, Lishi; Okhunov, Zhamshid; Margulis, Vitaly; Savage, Stephen J; Uchio, Edward; Landman, Jaime

    2018-04-06

    To compare the performance of 3 contemporary ureteroscopic biopsy devices for the histopathologic diagnosis of upper tract urothelial carcinoma (UTUC). We retrospectively reviewed 145 patients who underwent 182 urothelial biopsies using 2.4F backloaded cup biopsy forceps, a nitinol basket, or 3F standard cup biopsy forceps at 3 tertiary academic centers between 2011 and 2016. Experienced genitourinary pathologists provided an assessment of each specimen without knowledge of the device used for biopsy. For patients who underwent nephroureterectomy without neoadjuvant chemotherapy within 3 months of biopsy-proven UTUC diagnosis, the biopsy grade was compared with both the grade and stage of the surgical specimen. Biopsy utilization varied among the 3 institutions (P cup forceps was rated similarly to the nitinol basket (P >.05) and was favored over standard cup forceps specimens. Grade concordance was not affected by specimen size (P >.05), morphology (P >.1), or location (P >.5). No difference existed among the devices in the rate of acquiring a grade concordant biopsy; however, the backloaded cup forceps provided concordant biopsies that could be distinguished as low- and high-grade (P = .02). The backloaded cup forceps and nitinol basket obtained a higher quality urothelial specimen compared with standard cup forceps. Ureteroscopic biopsy device selection did not significantly impact the accuracy of the histologic diagnosis of UTUC. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Complications of percutaneous renal tumor biopsy: An analysis of 340 consecutive biopsies

    DEFF Research Database (Denmark)

    René Rasmussen, Lars; Loft, Martina; Høyer, Søren

    Purpose Ultrasound Guided Percutaneous Kidney Biopsy (UGPKB) plays a major role in diagnosis of renal tumours. There seems to be little consensus regarding post-biopsy observation period. We aim to identify complications in UGPKB among outpatients with a suspected malignant renal lesion as well...... as the timing of onset of these complications, helping to clarify the optimal observation period. Many studies in this field suggest a lower complication risk for outpatients compared to hospitalized patients. In the latter group, an observation period of 24h after biopsy is often recommended. Material...... discrepancy. Results As for one third of the patients, analysed up until now, we find a total of one major complication and a few minor, all arisen within less than 6 hours after biopsy. Conclusions Rates of both major and minor complications in UGPKB are very low suggesting a shorter observation period...

  16. Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors.

    Science.gov (United States)

    Chae, In Hye; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young

    2017-07-01

    To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma. A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed. Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.

  17. Flexible session management in a distributed environment

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Zach; /Wisconsin U., Madison; Bradley, Dan; /Wisconsin U., Madison; Tannenbaum, Todd; /Wisconsin U., Madison; Sfiligoi, Igor; /Fermilab

    2010-01-01

    Many secure communication libraries used by distributed systems, such as SSL, TLS, and Kerberos, fail to make a clear distinction between the authentication, session, and communication layers. In this paper we introduce CEDAR, the secure communication library used by the Condor High Throughput Computing software, and present the advantages to a distributed computing system resulting from CEDAR's separation of these layers. Regardless of the authentication method used, CEDAR establishes a secure session key, which has the flexibility to be used for multiple capabilities. We demonstrate how a layered approach to security sessions can avoid round-trips and latency inherent in network authentication. The creation of a distinct session management layer allows for optimizations to improve scalability by way of delegating sessions to other components in the system. This session delegation creates a chain of trust that reduces the overhead of establishing secure connections and enables centralized enforcement of system-wide security policies. Additionally, secure channels based upon UDP datagrams are often overlooked by existing libraries; we show how CEDAR's structure accommodates this as well. As an example of the utility of this work, we show how the use of delegated security sessions and other techniques inherent in CEDAR's architecture enables US CMS to meet their scalability requirements in deploying Condor over large-scale, wide-area grid systems.

  18. Flexible session management in a distributed environment

    International Nuclear Information System (INIS)

    Miller, Zach; Bradley, Dan; Tannenbaum, Todd; Sfiligoi, Igor

    2010-01-01

    Many secure communication libraries used by distributed systems, such as SSL, TLS, and Kerberos, fail to make a clear distinction between the authentication, session, and communication layers. In this paper we introduce CEDAR, the secure communication library used by the Condor High Throughput Computing software, and present the advantages to a distributed computing system resulting from CEDAR's separation of these layers. Regardless of the authentication method used, CEDAR establishes a secure session key, which has the flexibility to be used for multiple capabilities. We demonstrate how a layered approach to security sessions can avoid round-trips and latency inherent in network authentication. The creation of a distinct session management layer allows for optimizations to improve scalability by way of delegating sessions to other components in the system. This session delegation creates a chain of trust that reduces the overhead of establishing secure connections and enables centralized enforcement of system-wide security policies. Additionally, secure channels based upon UDP datagrams are often overlooked by existing libraries; we show how CEDAR's structure accommodates this as well. As an example of the utility of this work, we show how the use of delegated security sessions and other techniques inherent in CEDAR's architecture enables US CMS to meet their scalability requirements in deploying Condor over large-scale, wide-area grid systems.

  19. Flexible session management in a distributed environment

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Zach; Bradley, Dan; Tannenbaum, Todd [University of Wisconsin, Madison, WI (United States); Sfiligoi, Igor, E-mail: zmiller@cs.wisc.ed [Fermi National Acceleartor Laboratory, Batavia, IL (United States)

    2010-04-01

    Many secure communication libraries used by distributed systems, such as SSL, TLS, and Kerberos, fail to make a clear distinction between the authentication, session, and communication layers. In this paper we introduce CEDAR, the secure communication library used by the Condor High Throughput Computing software, and present the advantages to a distributed computing system resulting from CEDAR's separation of these layers. Regardless of the authentication method used, CEDAR establishes a secure session key, which has the flexibility to be used for multiple capabilities. We demonstrate how a layered approach to security sessions can avoid round-trips and latency inherent in network authentication. The creation of a distinct session management layer allows for optimizations to improve scalability by way of delegating sessions to other components in the system. This session delegation creates a chain of trust that reduces the overhead of establishing secure connections and enables centralized enforcement of system-wide security policies. Additionally, secure channels based upon UDP datagrams are often overlooked by existing libraries; we show how CEDAR's structure accommodates this as well. As an example of the utility of this work, we show how the use of delegated security sessions and other techniques inherent in CEDAR's architecture enables US CMS to meet their scalability requirements in deploying Condor over large-scale, wide-area grid systems.

  20. Flexible session management in a distributed environment

    Science.gov (United States)

    Miller, Zach; Bradley, Dan; Tannenbaum, Todd; Sfiligoi, Igor

    2010-04-01

    Many secure communication libraries used by distributed systems, such as SSL, TLS, and Kerberos, fail to make a clear distinction between the authentication, session, and communication layers. In this paper we introduce CEDAR, the secure communication library used by the Condor High Throughput Computing software, and present the advantages to a distributed computing system resulting from CEDAR's separation of these layers. Regardless of the authentication method used, CEDAR establishes a secure session key, which has the flexibility to be used for multiple capabilities. We demonstrate how a layered approach to security sessions can avoid round-trips and latency inherent in network authentication. The creation of a distinct session management layer allows for optimizations to improve scalability by way of delegating sessions to other components in the system. This session delegation creates a chain of trust that reduces the overhead of establishing secure connections and enables centralized enforcement of system-wide security policies. Additionally, secure channels based upon UDP datagrams are often overlooked by existing libraries; we show how CEDAR's structure accommodates this as well. As an example of the utility of this work, we show how the use of delegated security sessions and other techniques inherent in CEDAR's architecture enables US CMS to meet their scalability requirements in deploying Condor over large-scale, wide-area grid systems.

  1. Ethics case reflection sessions: Enablers and barriers.

    Science.gov (United States)

    Bartholdson, Cecilia; Molewijk, Bert; Lützén, Kim; Blomgren, Klas; Pergert, Pernilla

    2018-03-01

    In previous research on ethics case reflection (ECR) sessions about specific cases, healthcare professionals in childhood cancer care were clarifying their perspectives on the ethical issue to resolve their main concern of consolidating care. When perspectives were clarified, consequences in the team included 'increased understanding', 'group strengthening' and 'decision grounding'. Additional analysis of the data was needed on conditions that could contribute to the quality of ECR sessions. The aim of this study was to explore conditions for clarifying perspectives during ECR sessions. Data were collected from observations and interviews and the results emerged from an inductive analysis using grounded theory. Participants and research context: Six observations during ECR sessions and 10 interviews were performed with healthcare professionals working in childhood cancer care and advanced paediatric homecare. Ethical considerations: The study was approved by a regional ethical review board. Participants were informed about their voluntary involvement and that they could withdraw their participation without explaining why. Two categories emerged: organizational enablers and barriers and team-related enablers and barriers. Organizational enablers and barriers included the following sub-categories: the timing of the ECR session, the structure during the ECR session and the climate during the ECR session. Sub-categories to team-related enablers and barriers were identified as space for inter-professional perspectives, varying levels of ethical skills and space for the patient's and the family's perspectives. Space for inter-professional perspectives included the dominance of a particular perspective that can result from hierarchical positions. The medical perspective is relevant for understanding the child's situation but should not dominate the ethical reflection. Conditions for ECR sessions have been explored and the new knowledge can be used when training

  2. Expansion of protein domain repeats.

    Directory of Open Access Journals (Sweden)

    Asa K Björklund

    2006-08-01

    Full Text Available Many proteins, especially in eukaryotes, contain tandem repeats of several domains from the same family. These repeats have a variety of binding properties and are involved in protein-protein interactions as well as binding to other ligands such as DNA and RNA. The rapid expansion of protein domain repeats is assumed to have evolved through internal tandem duplications. However, the exact mechanisms behind these tandem duplications are not well-understood. Here, we have studied the evolution, function, protein structure, gene structure, and phylogenetic distribution of domain repeats. For this purpose we have assigned Pfam-A domain families to 24 proteomes with more sensitive domain assignments in the repeat regions. These assignments confirmed previous findings that eukaryotes, and in particular vertebrates, contain a much higher fraction of proteins with repeats compared with prokaryotes. The internal sequence similarity in each protein revealed that the domain repeats are often expanded through duplications of several domains at a time, while the duplication of one domain is less common. Many of the repeats appear to have been duplicated in the middle of the repeat region. This is in strong contrast to the evolution of other proteins that mainly works through additions of single domains at either terminus. Further, we found that some domain families show distinct duplication patterns, e.g., nebulin domains have mainly been expanded with a unit of seven domains at a time, while duplications of other domain families involve varying numbers of domains. Finally, no common mechanism for the expansion of all repeats could be detected. We found that the duplication patterns show no dependence on the size of the domains. Further, repeat expansion in some families can possibly be explained by shuffling of exons. However, exon shuffling could not have created all repeats.

  3. [Use of MRI before biopsy in diagnosis of prostate cancer: Single-operator study].

    Science.gov (United States)

    Bassard, S; Mege, J-L

    2015-12-01

    The diagnostic for prostate cancer is changing. To improve the detection of this cancer, urologists expect a lot from the contribution of magnetic resonance imaging (MRI). What is the role of this imaging in prostate cancer detection? This is a retrospective study, from 2011 to 2013, mono-centric and single-operator. Of the 464 needle biopsy of the prostate (BP), we excluded those with PSA>20 ng/mL or digital rectal examination (DRE)>T3. The remaining 430 BP were submitted or not to a 1.5 tesla MRI with pelvic antenna. The primary aim is the overall detection of prostate cancer. Secondary aim was the detection rate during the first series of BP and repeat BP, between the two groups in the MRI group. MRI and MRI without populations are comparable for age (63.3 vs 64.6), PSA (6.10 vs 6.13), DRE>T1c, prostate volume (55.4 cm(3) vs 51.7 cm(3)). There is no significant difference in overall detection between the two groups (P=0.12). There is no significant difference in cancer detection between the first BP (P=0.13) and the repeat BP (P=0.07). There is a significant difference in the early detection of BP MRI group (P=0.03) but not for the BP repeat MRI group (P=0.07). For 108 BP iterative MRI group, there were 67 BP targeted "mentally" with MRI: 18 cancers were detected, making a 25% detection rate. This study helps to highlight the value of MRI in the early rounds of BP but we can ask the value of this imaging during repeat biopsies. Targeted biopsies "mentally" do not have the expected detection sensitivity and seems to require a three-dimensional reconstruction to be more effective. 5. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  4. Percutaneous biopsy of a metastatic common iliac lymph node using hydrodissection and a semi-automated biopsy gun

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Seong Yoon; Park, Byung Kwan [Dept. of Radiology, amsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2017-06-15

    Percutaneous biopsy is a less invasive technique for sampling the tissue than laparoscopic biopsy or exploratory laparotomy. However, it is difficult to perform biopsy of a deep-seated lesion because of the possibility of damage to the critical organs. Recently, we successfully performed CT-guided biopsy of a metastatic common iliac lymph node using hydrodissection and semi-automated biopsy devices. The purpose of this case report was to show how to perform hydrodissection and how to use a semi-automated gun for safe biopsy of a metastatic common iliac lymph node.

  5. Using the epigenetic field defect to detect prostate cancer in biopsy negative patients.

    Science.gov (United States)

    Truong, Matthew; Yang, Bing; Livermore, Andrew; Wagner, Jennifer; Weeratunga, Puspha; Huang, Wei; Dhir, Rajiv; Nelson, Joel; Lin, Daniel W; Jarrard, David F

    2013-06-01

    We determined whether a novel combination of field defect DNA methylation markers could predict the presence of prostate cancer using histologically normal transrectal ultrasound guided biopsy cores. Methylation was assessed using quantitative Pyrosequencing® in a training set consisting of 65 nontumor and tumor associated prostate tissues from University of Wisconsin. A multiplex model was generated using multivariate logistic regression and externally validated in blinded fashion in a set of 47 nontumor and tumor associated biopsy specimens from University of Washington. We observed robust methylation differences in all genes at all CpGs assayed (p prostate cancer (AUC 0.774, p = 0.001) and had a negative predictive value of 0.909. Comparison between 2 separate cores in patients in this validation set revealed similar methylation defects, indicating detection of a widespread field defect. A widespread epigenetic field defect can be used to detect prostate cancer in patients with histologically negative biopsies. To our knowledge this assay is unique, in that it detects alterations in nontumor cells. With further validation this marker combination (EVX1 and FGF1) has the potential to decrease the need for repeat prostate biopsies, a procedure associated with cost and complications. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  6. Systemic Air Embolism After CT-guided Lung Biopsy

    Science.gov (United States)

    2017-11-27

    Patients Who Underwent Percutaneous Lung Biopsy Under CT Guidance; Patients Who Presented Systemic Air Embolism After Percutaneous Lung Biopsy Under CT Guidance Depicted at the Time of the Procedure on a Whole Thoracic CT

  7. Teaching Students about Research: Classroom Poster Sessions.

    Science.gov (United States)

    Crowley-Long, Kathleen; And Others

    1997-01-01

    Finds that undergraduate students in an introductory psychology class acquired more favorable attitudes toward research as a result of their active participation in the creation and presentation of a poster that illustrates their independent work. Appends poster session instructions. (RS)

  8. Work session on the SAR. Pt. 2

    International Nuclear Information System (INIS)

    Burkart, K.

    1980-01-01

    The present paper contains the tables of the contribution of K. Burkart 'Work Session on the SAR' to the IAEA Interregional Training Course held in Sept/Oct. 1980 at the Kernforschungszentrum Karlsruhe. (RW)

  9. Session summary: Electronics, triggering and data acquisition

    International Nuclear Information System (INIS)

    Rescia, S.

    1991-12-01

    The session focused on the requirements for calorimetry at the SSC/LHC. Results on new readout techniques, calibration, radiation hard electronics and semiconductor devices, analog and digital front and electronics, and trigger strategies are presented

  10. Liver CT-guided aspirative biopsies

    International Nuclear Information System (INIS)

    Santos, Gilda da Cunha; Carvalho, Leda Viegas de; Chojniak, Rubens; Morini, Sandra Regina

    1996-01-01

    Sixty-eight CT-guided aspirative biopsies of hepatic nodules were performed at A.C. Camargo Hospital, Sao Paulo, Brazil, from 1992 to 1995. The cases were distributed as follow: 44(64.7%) with a positive diagnosis for neoplastic cells, 6(8.8%) with a negative diagnosis, and 14 (20.5%) with insufficient material. Of the positive cases (primary neoplasias and metastases), the cytological diagnosis was achieved in 39 cases. There were 36 cases of carcinoma (7 hepato carcinomas, 18 adenocarcinomas, 1 small cell carcinoma and 10 cases of unspecified differentiation), 2 cases of melanoma and 1 case of melanoma and 1 case of sarcoma. The correlation with histopathological exams showed no false positive cases and concordance between cytological and histopathological diagnosis. The results demonstrate that CT-guided aspirative biopsy of hepatic nodules permits a rapid diagnosis of neoplastic lesions, especially for the evaluation of metastases. (author)

  11. PATHOMORPHOLOGY OF ZERO BIOPSIES OF DONOR KIDNEYS

    Directory of Open Access Journals (Sweden)

    M. L. Arefjev

    2011-01-01

    Full Text Available There is well known fact that kidney transplants from Extended Criteria Donors may increase risk of De- layed Graft Function and Primary Non-Function of transplants. We have collected and tested 65 «zero» kidney biopsies from cadaver donors aged from 19 to 71 years old. In the pool of elderly donors who died from cerebrovascular accident the frequency of nephrosclerosis presentation was higher than in donors of yonger age who died from craniocephalic trauma. Nevertheless in the general donor pool the number of sclerosed glomeruli was no more than 12%. We did not meet at all in the whole volume of material any bi- opsy with the severe degree of arteriosclerosis. The «zero» biopsies of cadaver kidneys is quite usable and unexpensive tool to measure the degree of nephrosclerosis in order to exclude kidneys which are not fitable for transplantation. 

  12. Summary of the relativistic heavy ion sessions

    International Nuclear Information System (INIS)

    Harris, J.W.

    1988-01-01

    The topics covered in the Relativistic Heavy Ion Sessions span four orders of magnitude in energy in the laboratory and a few more in theory. In the two years since the last Intersections conference, experiments in the field of very high energy heavy ion research have begun at CERN and Brookhaven. The prime motivation for these experiments is the possibility of forming quark matter. This paper is a review of the topics covered in the Relativistic Heavy Ion Sessions

  13. Repeated cue exposure effects on subjective and physiological indices of chocolate craving

    OpenAIRE

    Van Gucht, Dinska; Vansteenwegen, Debora; Beckers, Tom; Hermans, Dirk; Baeyens, Frank; Van den Bergh, Omer

    2008-01-01

    The aim of this study is to investigate the effects of repeated unreinforced exposure to chocolate cues in persons reporting chocolate craving. Participants in the experimental group (n=40) received 10 consecutive brief exposures to chocolate cues in each of two sessions, separated by 1-3 days. Control participants (n=18) received two exposures at the start and end of each session. Chocolate craving was measured (alternately) through subjective report and the amount of saliva secretion to cho...

  14. Survival after stereotactic biopsy of malignant gliomas

    International Nuclear Information System (INIS)

    Coffey, R.J.; Lunsford, L.D.; Taylor, F.H.

    1988-01-01

    For many patients with malignant gliomas in inaccessible or functionally important locations, stereotactic biopsy followed by radiation therapy (RT) may be a more appropriate initial treatment than craniotomy and tumor resection. We studied the long term survival in 91 consecutive patients with malignant gliomas diagnosed by stereotactic biopsy: 64 had glioblastoma multiforme (GBM) and 27 had anaplastic astrocytoma (AA). Sixty-four per cent of the GBMs and 33% of the AAs involved deep or midline cerebral structures. The treatment prescribed after biopsy, the tumor location, the histological findings, and the patient's age at presentation (for AAs) were statistically important factors determining patient survival. If adequate RT (tumor dose of 5000 to 6000 cGy) was not prescribed, the median survival was less than or equal to 11 weeks regardless of tumor histology or location. The median survival for patients with deep or midline tumors who completed RT was similar in AA (19.4 weeks) and GBM (27 weeks) cases. Histology was an important predictor of survival only for patients with adequately treated lobar tumors. The median survival in lobar GBM patients who completed RT was 46.9 weeks, and that in lobar AA patients who completed RT was 129 weeks. Cytoreductive surgery had no statistically significant effect on survival. Among the clinical factors examined, age of less than 40 years at presentation was associated with prolonged survival only in AA patients. Constellations of clinical features, tumor location, histological diagnosis, and treatment prescribed were related to survival time

  15. Breast MR biopsy: Pathological and radiological correlation

    International Nuclear Information System (INIS)

    Dratwa, Chloe; Chopier, Jocelyne; Jalaguier-Coudray, Aurelie; Thomassin-Piana, Jeanne; Gonin, Julie; Antoine, Martine; Trop, Isabelle; Darai, Emile; Thomassin-Naggara, Isabelle

    2016-01-01

    To identify pathological features for sample analysis of magnetic resonance imaging-guided vaccum-assisted breast biopsy (MRIgVaBB) to optimize radio pathological correlation and identify discordant benign result. Databases of two centres were queried to identify MRIgVaBB performed between January 2009 and February 2013. A cohort of 197 women (mean age: 54.5 years (24-77)) with 208 lesions was identified. We retrospectively analyzed all prebiopsy MRI examinations according to the new BI-RADS lexicon, and all biopsy samples to describe the lesion of interest, its interface with the surrounding breast tissue and other associated features. The malignancy rate was 26.0 % (54/208) with an underestimation rate of 15.67 % (5/32). A visible interface at pathology between a biopsied lesion and the surrounding breast tissue was more frequently identified in mass enhancement compared to NME or focus (p = 0.0003). Regional NME was correlated with a high degree of fibrosis (p = 0.001) and the presence of PASH (p = 0.0007). Linear or segmental NME was correlated with the presence of periductal mastitis (p = 0.0003). The description of a visible interface between the target lesion and the surrounding tissue is crucial to confirm the correct targeting of an MR mass or a NME. (orig.)

  16. Film repeats in radiology department

    International Nuclear Information System (INIS)

    Suwan, A. Z.; Al-Shakharah, A. I

    1997-01-01

    During a one year period, 4910 radiographs of 55780 films were repeated. The objective of our study was to analyse and to classify the causes in order to minimize the repeats, cut the expenses and to provide optimal radiographs for accurate diagnosis. Analysis of the different factors revealed that, 43.6% of film repeats in our service were due to faults in exposure factors, centering comprises 15.9% of the repeats, while too much collimation was responsible for 7.6% of these repeats. All of which can be decreased by awareness and programmed training of technicians. Film blurring caused by patient motion was also responsible for 4.9% for radiographs reexamination, which can be minimized by detailed explanation to the patient and providing the necessary privacy. Fogging of X-Ray films by improper storage or inadequate handling or processing faults were responsible for 14.5% in repeats in our study. Methods and criteria for proper storage and handling of films were discussed. Recommendation for using modern day-light and laser processor has been high lighted. Artefacts are noticeably high in our cases, due to spinal dresses and frequent usage of precious metals for c osmotic purposes in this part of the world. The repeated films comprise 8.8% of all films We conclude that, the main factor responsible for repeats of up to 81.6% of cases was the technologists, thus emphasizing the importance of adequate training of the technologists. (authors). 15 refs., 9 figs., 1 table

  17. Nifty Nines and Repeating Decimals

    Science.gov (United States)

    Brown, Scott A.

    2016-01-01

    The traditional technique for converting repeating decimals to common fractions can be found in nearly every algebra textbook that has been published, as well as in many precalculus texts. However, students generally encounter repeating decimal numerals earlier than high school when they study rational numbers in prealgebra classes. Therefore, how…

  18. Repeated Prescribed Burning in Aspen

    Science.gov (United States)

    Donald A. Perala

    1974-01-01

    Infrequent burning weather, low flammability of the aspen-hardwood association, and prolific sprouting and seeding of shrubs and hardwoods made repeated dormant season burning a poor tool to convert good site aspen to conifers. Repeat fall burns for wildlife habitat maintenance is workable if species composition changes are not important.

  19. MR-guided transgluteal biopsies with an open low-field system in patients with clinically suspected prostate cancer: technique and preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Zangos, Stephan [Johann Wolfgang Goethe-University, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt/Main (Germany); Johann Wolfgang Goethe-University, Institute for Diagnostic and Interventional Radiology, Frankfurt/Main (Germany); Eichler, Katrin; Engelmann, Kerstin; Ahmed, Mukhtiar; Dettmer, Sebastian; Herzog, Christopher; Pegios, Wasilios; Wetter, A.; Lehnert, Thomas; Mack, Martin G.; Vogl, Thomas J. [Johann Wolfgang Goethe-University, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt/Main (Germany)

    2005-01-01

    The purpose of this study was to examine the feasibility and safety of MR-guided biopsies with a transgluteal approach in patients with uncertain or suspicious prostate lesions. Twenty-five patients with uncertain or suspicious focal prostate lesions detected by high-field MR imaging of the prostate gland using endorectal coil imaging were biopsied with a transgluteal approach in a low-field MRI system (0.2 T, Concerto, Siemens). The procedures were guided using T1-weighted FLASH sequences. The prostate gland was biopsied repeatedly with a coaxial technique through a 15-gauge pencil tip with a 16-gauge biopsy handy (median 3.8 samples per patient). Complications and biopsy findings were documented retrospectively. Using T1-weighted sequences biopsy procedures were performed successfully with MR guidance in all cases without any side effects or complications. The median intervention time was 11.3 min. Pathological findings revealed ten cases of hyperplasia or atrophy, three cases of prostatitis, ten cases of carcinoma and two cases of normal tissue. The clinical follow-up showed that in two patients prostate cancer was missed at MR-guided biopsy. Transgluteal MR-guided biopsy of the prostate gland is a safe and promising approach for histological clarification of uncertain or suspicious lesions. (orig.)

  20. Percutaneous fine needle aspiration biopsy for the intrathoracic lesions: What is the meaning of non-diagnostic results?

    International Nuclear Information System (INIS)

    Kim, Min Ju; Lee, Jin Seong; Do, Kyung Hyun; Seo, Joon Beom; Song, Koun Sik; Lim, Tae Hwan

    2003-01-01

    To know what is the meaning of non-diagnostic results of fine needle aspiration biopsy (FNAB) and whether repeated aspiration is needed or not in those situations. We reviewed 1845 patients who underwent FNAB from 1997 to 2001. Non-diagnostic results of the first FNAB were divided into four groups: insufficient number of cells, inflammatory cells, necrotic debris and atypical cells. We analyzed final diagnosis of 531 patients who had non-diagnostic results from the first FNAB. Among them, 207 lesions were re-biopsied because of clinical and radiologic suspicion of malignancy. The diagnostic yield of repeated FNAB was analyzed and compared with the results of the first FNAB. Among 255 cases with 'inflammatory cells only' results, 120 cases were confirmed benignancy on follow-up. Twenty nine of 50 stypical cells (58%) were malignant of follow-up. One hundred one of 207 repeated FNAB resulted in the non-diagnostic reports, and 106 of 207 repeated FNAB were diagnosed as specific diagnosis. Among thirty lesions showing atypical cells on the repeated FNAB, 22 (73%) were identified as malignant neoplasms. When the specimen of FNAB shows atypical cells, the possibility of malignancy is very high. When the results of FNAB is non-diagnostic in the cases with clinical and radiological suspicion of malignancy, repeated FNAB procedures should be seriously considered and will be helpful for accurate specific diagnosis

  1. Assessing treatment integrity in cognitive-behavioral therapy: comparing session segments with entire sessions.

    Science.gov (United States)

    Weck, Florian; Grikscheit, Florian; Höfling, Volkmar; Stangier, Ulrich

    2014-07-01

    The evaluation of treatment integrity (therapist adherence and competence) is a necessary condition to ensure the internal and external validity of psychotherapy research. However, the evaluation process is associated with high costs, because therapy sessions must be rated by experienced clinicians. It is debatable whether rating session segments is an adequate alternative to rating entire sessions. Four judges evaluated treatment integrity (i.e., therapist adherence and competence) in 84 randomly selected videotapes of cognitive-behavioral therapy for major depressive disorder, social anxiety disorder, and hypochondriasis (from three different treatment outcome studies). In each case, two judges provided ratings based on entire therapy sessions and two on session segments only (i.e., the middle third of the entire sessions). Interrater reliability of adherence and competence evaluations proved satisfactory for ratings based on segments and the level of reliability did not differ from ratings based on entire sessions. Ratings of treatment integrity that were based on entire sessions and session segments were strongly correlated (r=.62 for adherence and r=.73 for competence). The relationship between treatment integrity and outcome was comparable for ratings based on session segments and those based on entire sessions. However, significant relationships between therapist competence and therapy outcome were only found in the treatment of social anxiety disorder. Ratings based on segments proved to be adequate for the evaluation of treatment integrity. The findings demonstrate that session segments are an adequate and cost-effective alternative to entire sessions for the evaluation of therapist adherence and competence. Copyright © 2014. Published by Elsevier Ltd.

  2. Tevatron serial data repeater system

    International Nuclear Information System (INIS)

    Ducar, R.J.

    1981-01-01

    A ten megabit per second serial data repeater system has been developed for the 6.28km Tevatron accelerator. The repeaters are positioned at each of the thirty service buildings and accommodate control and abort system communications as well as distribution of the Tevatron time and energy clocks. The repeaters are transparent to the particular protocol of the transmissions. Serial data are encoded locally as unipolar two volt signals employing the self-clocking Manchester Bi-Phase code. The repeaters modulate the local signals to low-power bursts of 50 MHz rf carrier for the 260m transmission between service buildings. The repeaters also demodulate the transmission and restructure the data for local utilization. The employment of frequency discrimination techniques yields high immunity to the characteristic noise spectrum

  3. All-photonic quantum repeaters

    Science.gov (United States)

    Azuma, Koji; Tamaki, Kiyoshi; Lo, Hoi-Kwong

    2015-01-01

    Quantum communication holds promise for unconditionally secure transmission of secret messages and faithful transfer of unknown quantum states. Photons appear to be the medium of choice for quantum communication. Owing to photon losses, robust quantum communication over long lossy channels requires quantum repeaters. It is widely believed that a necessary and highly demanding requirement for quantum repeaters is the existence of matter quantum memories. Here we show that such a requirement is, in fact, unnecessary by introducing the concept of all-photonic quantum repeaters based on flying qubits. In particular, we present a protocol based on photonic cluster-state machine guns and a loss-tolerant measurement equipped with local high-speed active feedforwards. We show that, with such all-photonic quantum repeaters, the communication efficiency scales polynomially with the channel distance. Our result paves a new route towards quantum repeaters with efficient single-photon sources rather than matter quantum memories. PMID:25873153

  4. Repeatability of visual acuity measurement.

    Science.gov (United States)

    Raasch, T W; Bailey, I L; Bullimore, M A

    1998-05-01

    This study investigates features of visual acuity chart design and acuity testing scoring methods which affect the validity and repeatability of visual acuity measurements. Visual acuity was measured using the Sloan and British Standard letter series, and Landolt rings. Identifiability of the different letters as a function of size was estimated, and expressed in the form of frequency-of-seeing curves. These functions were then used to simulate acuity measurements with a variety of chart designs and scoring criteria. Systematic relationships exist between chart design parameters and acuity score, and acuity score repeatability. In particular, an important feature of a chart, that largely determines the repeatability of visual acuity measurement, is the amount of size change attributed to each letter. The methods used to score visual acuity performance also affect repeatability. It is possible to evaluate acuity score validity and repeatability using the statistical principles discussed here.

  5. Automated gun biopsy of the prostate under ultrasound guide

    International Nuclear Information System (INIS)

    Yang, Ik; Lim, Jae Hoon; Ko, Young Tae; Lee, Dong Ho; Lim, Joo Won

    1994-01-01

    To assess the effectiveness and clinical usefulness of prostate biopsy by automated gun biopsy device under the transrectal ultrasonographic guidance, authors analysed the result of biopsy and the patients status after biopsy procedure. The subjects consisted of 24 patients with prostatic disease. Biopsy instrument was an automated gun biopsy device loaded with an 18 gauze biopsy needle. All the patients were admitted to the hospital. No analgesics was given. All the procedure was performed with the patient in left lateral decubitus. Biopsy was performed at 2-4 different points of the prostate in 22 cases, but recently, six different points were targeted in two patients. Biopsy specimens were sufficient in 21 cases but insufficient in three cases. Histologic examination of biopsy specimens showed that 13 cases were nodular hyperplasia, eight cases were cancerous and three cases were inflammation. There was no clinically significant complication. There was mild to moderate degree of pain in all patients. Tansrectal biopsy of the prostate with an automated gun biopsy device under ultrasonographic guidance is considered relatively easy, handy and useful procedure in patients with prostatic disease. The procedure may be performed on the out patient basis

  6. Nonfocal renal biopsies: adequacy and factors affecting a successful outcome.

    Science.gov (United States)

    Goldstein, Mark A; Atri, Mostafa; O'Malley, Martin; Jacks, Lindsay; John, Rohan; Herzenberg, Andrew; Reich, Heather; Ghai, Sangeet

    2013-01-01

    The purpose of this study was to evaluate factors affecting the success of ultrasound-guided core biopsy of kidneys and determine the optimum number of passes. This retrospective study evaluated 484 nonfocal renal biopsies performed with 18-gauge side-notch biopsy needles. Number of biopsy passes, serum creatinine, body mass index, needle type, transplant age, kidney size, diabetic status, and operator were evaluated as predictors of the number of biopsy passes. Four hundred seventy-four biopsies (338 transplant, 136 native) were included with mean number of passes 2.87 (3.1 native vs 2.78 transplant; P = 0.002). Mean number of glomeruli yielded per pass was 6.9 (7.2 transplant vs 6.1 native; P = 0.0002) with 3 passes adequate for histological diagnosis in 84% of biopsies. Native kidney, increasing serum creatinine level, trainee biopsy operator, and use of a Temno needle were found to be independent predictors of having more than 3 biopsy passes on multivariate analysis. Age, sex, body mass index, diabetic status, and kidney size were not associated with the number of biopsy passes. The success of a nonfocal renal biopsy has many influencing variables, and in the absence of an on-site electron microscopy technologist to immediately evaluate biopsy samples, 3 passes with an 18-gauge needle would be adequate in 84% of kidneys to achieve a histological diagnosis, with 2 passes needed for transplant kidneys to meet the Banff 97 criteria.

  7. 21 CFR 876.1075 - Gastroenterology-urology biopsy instrument.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gastroenterology-urology biopsy instrument. 876... SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Diagnostic Devices § 876.1075 Gastroenterology-urology biopsy instrument. (a) Identification. A gastroenterology-urology biopsy instrument is a...

  8. Pleural biopsy for indeterminate cases of pleural effusion | Ukadike ...

    African Journals Online (AJOL)

    Materials and Methods: This is a retrospective study of all consecutive cases of pleural biopsies done for indeterminate cause of pleural effusion in the University of Benin Teaching Hospital from December 2008 to May 2010, a total of 18months. Blind pleural biopsy was carried out using the Abram's Pleural Biopsy Needle.

  9. Diagnostic Ability of Percutaneous Needle Biopsy Immediately After Radiofrequency Ablation for Malignant Lung Tumors: An Initial Experience

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, Takaaki, E-mail: t-hasegawa@aichi-cc.jp [Aichi Cancer Center Hospital, Department of Diagnostic and Interventional Radiology (Japan); Kondo, Chiaki [Aichi Cancer Center Hospital, Department of Pathology and Molecular Diagnosis (Japan); Sato, Yozo; Inaba, Yoshitaka; Yamaura, Hidekazu; Kato, Mina; Murata, Shinichi; Onoda, Yui [Aichi Cancer Center Hospital, Department of Diagnostic and Interventional Radiology (Japan); Kuroda, Hiroaki; Sakao, Yukinori [Aichi Cancer Center Hospital, Department of Thoracic Surgery (Japan); Yatabe, Yasushi [Aichi Cancer Center Hospital, Department of Pathology and Molecular Diagnosis (Japan)

    2016-08-15

    PurposeTo evaluate the safety and diagnostic ability of percutaneous needle biopsy performed immediately after lung radiofrequency ablation (RFA).Materials and MethodsFrom May 2013 to April 2014, percutaneous needle biopsy was performed immediately after RFA for 3 patients (2 men and 1 woman, aged 57–76 years) who had lung tumors measuring 1.3–2.6 cm in diameter. All patients had prior history of malignancy, and all tumors were radiologically diagnosed as malignant. Obtained specimens were pathologically classified using standard hematoxylin and eosin staining.ResultsWe completed three planned sessions of RFA followed by percutaneous needle biopsy, all of which obtained tumor tissue that could be pathologically diagnosed. Two tumors were metastatic from renal clear cell carcinoma and rectal adenocarcinoma, respectively; one tumor was primary lung adenocarcinoma. There was no death or major complication related to the procedures. Although pneumothorax occurred in two patients, these resolved without the need for aspiration or chest tube placement. Tumor seeding was not observed, but 21 months after the procedure, one case developed local tumor progression that was treated by additional RFA.ConclusionPathologic diagnosis was possible by needle biopsy immediately after RFA for lung tumors. This technique may reduce the risks and efforts of performing biopsy and RFA on separate occasions.

  10. The gene expression and immunohistochemical time-course of diphenylcyclopropenone-induced contact allergy in healthy humans following repeated epicutaneous challenges

    DEFF Research Database (Denmark)

    Mose, Kristian F; Burton, Mark; Thomassen, Mads

    2017-01-01

    DPCP challenges to find the predominant gene expression pattern, (ii) the time-course of cell infiltration following repeated DPCP challenges and (iii) the transcriptome of a repeated CA exposure model. We obtained punch biopsies from control and DPCP-exposed skin from ten DPCP sensitized individuals...

  11. The effect of repeated measurements and working memory on the most comfortable level in the ANL test

    DEFF Research Database (Denmark)

    Brännström, K Jonas; Olsen, Steen Østergaard; Holm, Lucas

    2014-01-01

    interleaved methodology during one session using a non-semantic version. Phonological (PWM) and visuospatial working memory (VSWM) was measured. STUDY SAMPLE: Thirty-two normal-hearing adults. RESULTS: Repeated measures ANOVA, intraclass correlations, and the coefficient of repeatability (CR) were used...

  12. 47 CFR 97.513 - VE session manager requirements.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false VE session manager requirements. 97.513 Section... SERVICES AMATEUR RADIO SERVICE Qualifying Examination Systems § 97.513 VE session manager requirements. (a) A VE session manager may be selected by the VE team for each examination session. The VE session...

  13. Unguided bronchoscopic biopsy: Does yield increase with operator experience

    Directory of Open Access Journals (Sweden)

    Tyagi Rahul

    2017-08-01

    Full Text Available Background Bronchoscopic Forceps biopsy (Endobronchial Biopsy (EBB and Trans Bronchial Lung Biopsy (TBLB are commonly performed for diagnosis in patients with endobronchial abnormalities or diffuse parenchymal involvement. As the operator gains experience his yield of various diagnostic bronchoscopic biopsies is expected to increase, however, no studies on the subject are available in literature. Aims To determine the effect of on- job experience on the yield of unguided bronchoscopic biopsies. Methods A total of 244 bronchoscopies were performed between Oct 2013 and Oct 2016. A retrospective analysis of all these bronchoscopies was undertaken. All patients who underwent biopsy were included in the study. Patients were divided into two groups with first group (Group A comprising of biopsies done between Oct 2013 to Apr 2015 and second group comprising biopsies done between May 2015 to Oct 2016 (Group B. The diagnostic yield in two groups was compared. Results Total 71 bronchoscopic biopsies were performed during Oct 2013 to Oct 2016. 36 patients were included in group A and 35 patients were included in group B. The groups were matched in demographic profile, clinical diagnosis, bronchoscopic findings and type of biopsy undertaken. The biopsy was diagnostic in 31 patient (43.6 per cent and nondiagnostic in 33 patients (46.4 per cent. There were 15 diagnostic biopsies in group A and 16 diagnostic biopsies in group B. The difference in the diagnostic biopsies between the two groups was not significant. Conclusion There was no significant impact of on job experience on diagnostic yield of biopsies. This may be due to adequate exposure during training leading to a diagnostic plateau being reached.

  14. Visual assessment of the cervical vertebral maturation stages: A study of diagnostic accuracy and repeatability.

    Science.gov (United States)

    Perinetti, Giuseppe; Caprioglio, Alberto; Contardo, Luca

    2014-11-01

    To evaluate the diagnostic accuracy and repeatability of the visual assessment of the cervical vertebral maturation (CVM) stages. Ten operators underwent training sessions in visual assessment of CVM staging. Subsequently, they were asked to stage 72 cases equally divided into the six stages. Such assessment was repeated twice in two sessions (T1 and T2) 4 weeks apart. A reference standard for each case was created according to a cephalometric analysis of both the concavities and shapes of the cervical vertebrae. The overall agreement with the reference standard was about 68% for both sessions and 76.9% for intrarater repeatability. The overall kappa coefficients with the reference standard were up to 0.86 for both sessions, and 0.88 for intrarater repeatability. Overall, disagreements one stage and twp stage apart were 23.5% (T1) and 5.1% (T2), respectively. Sensitivity ranged from 53.3% for CS5 (T1) to 99.9% for CS1 (T2), positive predictive values ranged from 52.4% for CS5 (T2) to 94.3% for CS6 (T1), and accuracy ranged from 83.6% for CS4 (T2) to 94.9% for CS1 (T1). Visual assessment of the CVM stages is accurate and repeatable to a satisfactory level. About one in three cases remain misclassified; disagreement is generally limited to one stage and is mostly seen in stages 4 and 5.

  15. Migration of Gelfoam to the gallbladder after liver biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Riddle, Chris [The Hospital for Sick Children, Image Guided Therapy, Department of Diagnostic Imaging, Toronto (Canada); Dalhousie University, School of Medicine, Halifax (Canada); Ahmed, Bilal [University of Toronto School of Medicine, Toronto (Canada); Doyle, John [The Hospital for Sick Children, Department of Hematology/Oncology, Toronto (Canada); Connolly, Bairbre L. [The Hospital for Sick Children, Image Guided Therapy, Department of Diagnostic Imaging, Toronto (Canada)

    2008-07-15

    Liver biopsy is a common procedure, with an inherent risk of bleeding. There are different ways to help avoid hemorrhage, including biopsy through a transjugular venous route or embolization of the tract with liquid or solid materials. We describe an image-guided percutaneous core needle liver biopsy with tract embolization using thick Gelfoam slurry in a pediatric oncology patient. Imaging studies acquired after the biopsy indicated that the Gelfoam mixture had likely migrated to the gallbladder and common bile duct. We report this rare occurrence with its striking imaging in order to make those performing biopsies aware of this possibility. (orig.)

  16. Image-guided breast biopsy: state-of-the-art

    Energy Technology Data Exchange (ETDEWEB)

    O' Flynn, E.A.M., E-mail: lizoflynn@doctors.org.u [South East London Breast Screening Programme and National Breast Screening Training Centre, Kings College Hospital NHS Foundation Trust, London SE5 9RS (United Kingdom); Wilson, A.R.M.; Michell, M.J. [South East London Breast Screening Programme and National Breast Screening Training Centre, Kings College Hospital NHS Foundation Trust, London SE5 9RS (United Kingdom)

    2010-04-15

    Percutaneous image-guided breast biopsy is widely practised to evaluate predominantly non-palpable breast lesions. There has been steady development in percutaneous biopsy techniques. Fine-needle aspiration cytology was the original method of sampling, followed in the early 1990s by large core needle biopsy. The accuracy of both has been improved by ultrasound and stereotactic guidance. Larger bore vacuum-assisted biopsy devices became available in the late 1990s and are now commonplace in most breast units. We review the different types of breast biopsy devices currently available together with various localization techniques used, focusing on their advantages, limitations and current controversial clinical management issues.

  17. Development and validation of a 6-item working alliance questionnaire for repeated administrations during psychotherapy.

    Science.gov (United States)

    Falkenström, Fredrik; Hatcher, Robert L; Skjulsvik, Tommy; Larsson, Mattias Holmqvist; Holmqvist, Rolf

    2015-03-01

    Recently, researchers have started to measure the working alliance repeatedly across sessions of psychotherapy, relating the working alliance to symptom change session by session. Responding to questionnaires after each session can become tedious, leading to careless responses and/or increasing levels of missing data. Therefore, assessment with the briefest possible instrument is desirable. Because previous research on the Working Alliance Inventory has found the separation of the Goal and Task factors problematic, the present study examined the psychometric properties of a 2-factor, 6-item working alliance measure, adapted from the Working Alliance Inventory, in 3 patient samples (ns = 1,095, 235, and 234). Results showed that a bifactor model fit the data well across the 3 samples, and the factor structure was stable across 10 sessions of primary care counseling/psychotherapy. Although the bifactor model with 1 general and 2 specific factors outperformed the 1-factor model in terms of model fit, dimensionality analyses based on the bifactor model results indicated that in practice the instrument is best treated as unidimensional. Results support the use of composite scores of all 6 items. The instrument was validated by replicating previous findings of session-by-session prediction of symptom reduction using the Autoregressive Latent Trajectory model. The 6-item working alliance scale, called the Session Alliance Inventory, is a promising alternative for researchers in search for a brief alliance measure to administer after every session. 2015 APA, all rights reserved

  18. Extrapleural paravertebral CT guided fine needle biopsy of subcarinal lymph nodes

    International Nuclear Information System (INIS)

    Tantawy, Wahid H.; El-Gemeie, Emad H.; Ibrahim, Ahmed S.; Mohamed, Mona A.

    2012-01-01

    Purpose: To report our experience in CT guided extrapleural paravertebral subcarinal lymph biopsy using a thin 25 gauge (25 G) thin needle without the need of injection of saline to widen the mediastinum. Materials and methods: Biopsy was performed using a 25 G needle which was advanced lateral to the vertebral body between the endothoracic fascia and the parietal pleura to gain access to subcarinal lymph nodes. One hundred and forty one patients were included in the study (74 females, 57 males). No artificial widening of the mediastinum using saline injection was required. The study was performed in the presence of a cytopathologist; sensitivity and specificity rates were calculated. Complications were documented for each case especially for pneumothorax and haemorrhage. Results: Cytopathological diagnosis was reached in all cases. All re-aspirations were done in the same session to reach a primary diagnosis at the time of the biopsy. Imunophenotyping study was done in 94 cases to confirm the primary diagnosis and to classify the malignant lesions. No pneumothorax was encountered. Small haematomas were noted in 5 cases (3.5%). Cytopathology showed a sensitivity of 97.2% and specificity of 100%. By adding immunophenotyping a 100% sensitivity and specificity was achieved. Conclusion: Fine needle aspiration cytology (FNAC) using a 25 gauge needle for subcarinal lymph nodes via a percutaneous extrapleural paravertebral CT guided approach is a safe, minimally invasive, and tolerable procedure yielding a high sensitivity and specificity rates without the need of artificial widening

  19. Extrapleural paravertebral CT guided fine needle biopsy of subcarinal lymph nodes

    Energy Technology Data Exchange (ETDEWEB)

    Tantawy, Wahid H., E-mail: tantawyw@yahoo.com [Radiology Department, Faculty of Medicine, Ain Shams University, Egypt Abbassyia square, Cairo (Egypt); El-Gemeie, Emad H. [Pathology Department, National Cancer Institute, Fom El Khalige Faculty of Medicine, Cairo University (Egypt); Ibrahim, Ahmed S., E-mail: asibrahima@gmail.com [Radiology Department, Faculty of Medicine, Ain Shams University, Egypt Abbassyia square, Cairo (Egypt); Mohamed, Mona A. [Radiology Department, Faculty of Medicine, Ain Shams University, Egypt Abbassyia square, Cairo (Egypt)

    2012-10-15

    Purpose: To report our experience in CT guided extrapleural paravertebral subcarinal lymph biopsy using a thin 25 gauge (25 G) thin needle without the need of injection of saline to widen the mediastinum. Materials and methods: Biopsy was performed using a 25 G needle which was advanced lateral to the vertebral body between the endothoracic fascia and the parietal pleura to gain access to subcarinal lymph nodes. One hundred and forty one patients were included in the study (74 females, 57 males). No artificial widening of the mediastinum using saline injection was required. The study was performed in the presence of a cytopathologist; sensitivity and specificity rates were calculated. Complications were documented for each case especially for pneumothorax and haemorrhage. Results: Cytopathological diagnosis was reached in all cases. All re-aspirations were done in the same session to reach a primary diagnosis at the time of the biopsy. Imunophenotyping study was done in 94 cases to confirm the primary diagnosis and to classify the malignant lesions. No pneumothorax was encountered. Small haematomas were noted in 5 cases (3.5%). Cytopathology showed a sensitivity of 97.2% and specificity of 100%. By adding immunophenotyping a 100% sensitivity and specificity was achieved. Conclusion: Fine needle aspiration cytology (FNAC) using a 25 gauge needle for subcarinal lymph nodes via a percutaneous extrapleural paravertebral CT guided approach is a safe, minimally invasive, and tolerable procedure yielding a high sensitivity and specificity rates without the need of artificial widening.

  20. Multiple biopsy probe sampling enabled minimally invasive electrical impedance tomography

    International Nuclear Information System (INIS)

    Shini, Mohanad; Rubinsky, Boris

    2008-01-01

    Biopsies are a reliable method for examining tissues and organs inside the body, in particular for detection of tumors. However, a single biopsy produces only limited information on the site from which it is taken. Therefore, tumor detection now employs multiple biopsy samplings to examine larger volumes of tissue. Nevertheless, even with multiple biopsies, the information remains discrete, while the costs of biopsy increase. Here we propose and evaluate the feasibility of using minimally invasive medical imaging as a means to overcome the limitations of discrete biopsy sampling. The minimally invasive medical imaging technique employs the biopsy probe as electrodes for measurements of electrical impedance tomography relevant data during each biopsy sampling. The data from multiple samplings are combined and used to produce an EIT image of the tissue. Two- and three-dimensional mathematical simulations confirm that the minimally invasive medical imaging technique can produce electrical impedance tomography images of the tissues between the biopsy probe insertion sites. We show that these images can detect tumors that would be missed with multiple biopsy samplings only, and that the technique may facilitate the detection of tumors with fewer biopsies, thereby reducing the cost of cancer detection

  1. Accuracy of percutaneous lung biopsy for invasive pulmonary aspergillosis

    Energy Technology Data Exchange (ETDEWEB)

    Hoffer, F.A. [Dept. of Diagnostic Imaging, St. Jude Children' s Research Hospital, Memphis, TN (United States); Gow, K.; Davidoff, A. [Dept. of Surgery, St. Jude Children' s Research Hospital, Memphis, TN (United States); Flynn, P.M. [Dept. of Infectious Diseases, St. Jude Children' s Research Hospital, Memphis, TN (United States)

    2001-03-01

    Background. Invasive pulmonary aspergillosis is fulminant and often fatal in immunosuppressed patients. Percutaneous biopsy may select patients who could benefit from surgical resection. Objective. We sought to determine the accuracy of percutaneous biopsy for pediatric invasive pulmonary aspergillosis. Materials and methods. We retrospectively reviewed 28 imaging-guided percutaneous biopsies of the lungs of 24 children with suspected pulmonary aspergillosis. Twenty-two were being treated for malignancy and two for congenital immunodeficiency; 15 had received bone-marrow transplants. The accuracy of the percutaneous lung biopsy was determined by subsequent surgical resection, autopsy, or clinical course. Results. Histopathological studies showed ten biopsy specimens with septate hyphae, indicating a mold, and seven with Aspergillus flavus colonies in culture. The remaining 18 biopsies revealed no fungi. No patient had progressive aspergillosis after negative biopsy. Invasive pulmonary mold was detected by percutaneous biopsy with 100 % (10/10) sensitivity and 100 % (18/18) specificity. Percutaneous biopsy results influenced the surgical decision in 86 % (24 of 28) of the cases. Bleeding complicated the biopsy in 46 % (13/28) and hastened one death. Conclusion. Percutaneous biopsy of the lung is an accurate technique for the diagnosis of invasive pulmonary aspergillosis and correctly determines which immunosuppressed pediatric patients would benefit from therapeutic pulmonary resection. (orig.)

  2. Accuracy of percutaneous lung biopsy for invasive pulmonary aspergillosis

    International Nuclear Information System (INIS)

    Hoffer, F.A.; Gow, K.; Davidoff, A.; Flynn, P.M.

    2001-01-01

    Background. Invasive pulmonary aspergillosis is fulminant and often fatal in immunosuppressed patients. Percutaneous biopsy may select patients who could benefit from surgical resection. Objective. We sought to determine the accuracy of percutaneous biopsy for pediatric invasive pulmonary aspergillosis. Materials and methods. We retrospectively reviewed 28 imaging-guided percutaneous biopsies of the lungs of 24 children with suspected pulmonary aspergillosis. Twenty-two were being treated for malignancy and two for congenital immunodeficiency; 15 had received bone-marrow transplants. The accuracy of the percutaneous lung biopsy was determined by subsequent surgical resection, autopsy, or clinical course. Results. Histopathological studies showed ten biopsy specimens with septate hyphae, indicating a mold, and seven with Aspergillus flavus colonies in culture. The remaining 18 biopsies revealed no fungi. No patient had progressive aspergillosis after negative biopsy. Invasive pulmonary mold was detected by percutaneous biopsy with 100 % (10/10) sensitivity and 100 % (18/18) specificity. Percutaneous biopsy results influenced the surgical decision in 86 % (24 of 28) of the cases. Bleeding complicated the biopsy in 46 % (13/28) and hastened one death. Conclusion. Percutaneous biopsy of the lung is an accurate technique for the diagnosis of invasive pulmonary aspergillosis and correctly determines which immunosuppressed pediatric patients would benefit from therapeutic pulmonary resection. (orig.)

  3. Attendance at NHS mandatory training sessions.

    Science.gov (United States)

    Brand, Darren

    2015-02-17

    To identify factors that affect NHS healthcare professionals' attendance at mandatory training sessions. A quantitative approach was used, with a questionnaire sent to 400 randomly selected participants. A total of 122 responses were received, providing a mix of qualitative and quantitative data. Quantitative data were analysed using statistical methods. Open-ended responses were reviewed using thematic analysis. Clinical staff value mandatory training sessions highly. They are aware of the requirement to keep practice up-to-date and ensure patient safety remains a priority. However, changes to the delivery format of mandatory training sessions are required to enable staff to participate more easily, as staff are often unable to attend. The delivery of mandatory training should move from classroom-based sessions into the clinical area to maximise participation. Delivery should be assisted by local 'experts' who are able to customise course content to meet local requirements and the requirements of different staff groups. Improved arrangements to provide staff cover, for those attending training, would enable more staff to attend training sessions.

  4. Effects of repeated collaborative retrieval on individual memory vary as a function of recall versus recognition tasks.

    Science.gov (United States)

    Blumen, Helena M; Rajaram, Suparna

    2009-11-01

    Our research examines how prior group collaboration modulates later individual memory. We recently showed that repeated collaborative recall sessions benefit later individual recall more than a single collaborative recall session (Blumen & Rajaram, 2008). Current research compared the effects of repeated collaborative recall and repeated collaborative recognition on later individual recall and later individual recognition. A total of 192 participants studied a list of nouns and then completed three successive retrieval sessions in one of four conditions. While two collaborative recall sessions and two collaborative recognition sessions generated comparable levels of individual recall (CRecall-CRecall-I Recall approximately CRecognition-CRecognition-I Recall , Experiment 1a), two collaborative recognition sessions generated greater levels of individual recognition than two collaborative recall sessions (CRecognition-CRecognition- IRecognition > CRecall-CRecall- I Recognition , Experiment 1b). These findings are discussed in terms of two opposing mechanisms that operate during collaborative retrieval-re-exposure and retrieval disruption-and in terms of transfer-appropriate processing across collaborative and individual retrieval sessions.

  5. Transrectal ultrasound and needle biopsy of the prostate

    Directory of Open Access Journals (Sweden)

    Tomaž Smrkolj

    2016-01-01

    Full Text Available In the last 25 years widespread use of prostatic specific antigen caused a stage migration of prostate cancer towards localized disease at diagnosis, which resulted in transrectal ultrasound biopsy to become standard in clinical practice. Transrectal ultrasound examination of the prostate is used to diagnose benign prostatic diseases, e.g. benign prostatic enlargement, prostatitis, prostatic and seminal vesicle cysts. It is also important in detection of obstructive causes of male infertility. Transrectal ultrasound examination is performed most often in needle biopsy for prostate cancer diagnosis. Besides guiding systematic tissue core biopsy, characteristic ultrasound changes enables target biopsies of suspect areas. The article describes indications, contraindications, antibiotic prophylaxis, various biopsy templates and complications of the needle biopsy. Experience with transrectal ultrasound guided biopsy at Department of urology at University medical center in Ljubljana is presented.

  6. CT fluoroscopy-guided vs. multislice CT biopsy mode-guided lung biopsies: Accuracy, complications and radiation dose

    International Nuclear Information System (INIS)

    Prosch, Helmut; Stadler, Alfred; Schilling, Matthias; Bürklin, Sandra; Eisenhuber, Edith; Schober, Ewald; Mostbeck, Gerhard

    2012-01-01

    Background: The aim of this retrospective study was to compare the diagnostic accuracy, the frequency of complications, the duration of the interventions and the radiation doses of CT fluoroscopy (CTF) guided biopsies of lung lesions with those of multislice CT (MS-CT) biopsy mode-guided biopsies. Methods: Data and images from 124 consecutive patients undergoing CTF-guided lung biopsy (group A) and 132 MS-CT-biopsy mode-guided lung biopsy (group B) were reviewed. CTF-guided biopsies were performed on a Siemens Emotion 6 CT scanner with intermittent or continuous CT-fluoroscopy, MS-CT biopsy mode-guided biopsies were performed on a Siemens Emotion 16 CT scanner. All biopsies were performed with a coaxial needle technique. Results: The two groups (A vs. B) did not differ significantly regarding sensitivity (95.5% vs. 95.9%), specificity (96.7% vs. 95.5%), negative predictive value (87.9% vs. 84%) or positive predictive value (98.8% vs. 98.9%). Pneumothorax was observed in 30.0% and 32.5% of the patients, respectively. Chest tube placement was necessary in 4% (group A) and 13% (group B) of the patients. The duration of the intervention was significantly longer in group A (median 37 min vs. 32 min, p = 0.04). The mean CT dose index (CTDI) was 422 in group A and 36.3 in group B (p < 0.001). Conclusion: Compared to CTF-guided biopsies, chest biopsies using the MS-CT biopsy mode show dramatically lower CTDI levels. Although the diagnostic yield of the procedures do not differ significantly, biopsies using the MS-CT-biopsy mode have a three-fold higher rate of chest tube placement.

  7. Diagnosis of prostate cancer with needle biopsy: should all cases be biopsied before treatment?

    Science.gov (United States)

    Oranusi, C K; Ugezu, A I; Nwofor, Ame

    2012-01-01

    The triad of digital rectal examination (DRE), serum prostate specific antigen, and transrectal ultrasound-guided prostate biopsy is used in the detection of prostate cancer (PCa). It is recommended that all cases of PCa should be diagnosed with needle biopsy before treatment. The exclusion criteria for those that may not be suitable have not yet been defined. We reviewed all the patients diagnosed with PCa at the Nnamdi Azikiwe University Teaching Hospital Nnewi, Southeast, Nigeria, from January 2007 to December 2010. Relevant biodata and method of diagnosis of PCa before treatment were reviewed. A total of 133 patients had bilateral orchidectomy over the period. 120 (90.2%) had their diagnosis confirmed by needle biopsy before bilateral orchidectomy (category 1), while 13 (9.8%) had bilateral orchidectomy before diagnosis was confirmed. The method of diagnosis for category 1 patients was with lower urinary tract symptoms (LUTS), abnormal DRE findings, elevated prostate-specific antigen (PSA), and transrectal needle biopsy. For category 11 patients, diagnosis of PCa was suspected based on LUTS, abnormal DRE findings, and elevated PSA. Of this number, 11 (84.6%) had, in addition, sudden onset paraplegia at presentation, while 2 (15.4%) had severe uncontrolled hematuria at presentation. All the patients in both categories had needle biopsy confirmation of their disease. The sensitivity of PSA was 99.2%. Needle biopsy of the prostate is the preferred method for the diagnosis of PCa in most cases before treatment is undertaken. There are valid reasons why all PCas will not be diagnosed in this fashion. Elevated PSA when combined with an abnormal DRE finding increases the predictive value for cancer. In areas where pathologists are lacking, abnormal DRE and elevated PSA results can be a guide to proceed to treatment especially, where there is severe compromise of patients' quality of life due to symptoms of advanced PCa while awaiting confirmation.

  8. The biopsy of the boar testes using ultrasonographic examination

    Directory of Open Access Journals (Sweden)

    Laima Liepa

    2014-03-01

    Full Text Available The biopsy of live animal testes is an important clinical manipulation to control spermatogenesis and reproductive system pathologies. The aim was to develop a method of boar testes biopsy using a biopsy gun with ultrasound guidance and to investigate the influence of this procedure on the boar testes parenchyma and quality of ejaculate. The biopsy was carried out in six 8-month-old boars. Fourteen days prior to and 21 days after biopsy, the quality of ejaculate was examined (weight of ejaculate; concentration and motility of spermatozoa with a seven-day intervals. Ultrasound images of the testes parenchyma were recorded three times: directly before and 15 minutes after the biopsy, then 21 days after the procedure. The testes biopsies of generally anesthetized boars were performed with the biopsy gun for needle biopsy with a 12cm long, disposable 16-gauge needle 1.8mm in diameter (Vitesse through 1cm skin incision in the depth of 1.2-1.6cm of parenchyma. Fifteen minutes after the biopsy, macroscopic injures of the parenchyma of all the boar testes were not detected in the ultrasound image. Twenty one days after biopsy, the hyperechogenic line 0.1-0.2cm in diameter was seen in the testes parenchyma of six boars in the depth of 1.2-1.6cm. The biopsy of boar testes did not influence the quality of boars ejaculate. The ultrasonographic examination of boar testicles before the biopsy reduced possibilities to traumatize large blood vessels of the testes. A perfect boar testicular biopsy was easy to perform using ultrasonographic examination in the pigsty conditions.

  9. Analysis of repeated measures data

    CERN Document Server

    Islam, M Ataharul

    2017-01-01

    This book presents a broad range of statistical techniques to address emerging needs in the field of repeated measures. It also provides a comprehensive overview of extensions of generalized linear models for the bivariate exponential family of distributions, which represent a new development in analysing repeated measures data. The demand for statistical models for correlated outcomes has grown rapidly recently, mainly due to presence of two types of underlying associations: associations between outcomes, and associations between explanatory variables and outcomes. The book systematically addresses key problems arising in the modelling of repeated measures data, bearing in mind those factors that play a major role in estimating the underlying relationships between covariates and outcome variables for correlated outcome data. In addition, it presents new approaches to addressing current challenges in the field of repeated measures and models based on conditional and joint probabilities. Markov models of first...

  10. Repeated DNA sequences in fungi

    Energy Technology Data Exchange (ETDEWEB)

    Dutta, S K

    1974-11-01

    Several fungal species, representatives of all broad groups like basidiomycetes, ascomycetes and phycomycetes, were examined for the nature of repeated DNA sequences by DNA:DNA reassociation studies using hydroxyapatite chromatography. All of the fungal species tested contained 10 to 20 percent repeated DNA sequences. There are approximately 100 to 110 copies of repeated DNA sequences of approximately 4 x 10/sup 7/ daltons piece size of each. Repeated DNA sequence homoduplexes showed on average 5/sup 0/C difference of T/sub e/50 (temperature at which 50 percent duplexes dissociate) values from the corresponding homoduplexes of unfractionated whole DNA. It is suggested that a part of repetitive sequences in fungi constitutes mitochondrial DNA and a part of it constitutes nuclear DNA. (auth)

  11. Magnetic resonance imaging-guided biopsies may improve diagnosis in biopsy-naive men with suspicion of prostate cancer

    DEFF Research Database (Denmark)

    Winther, Mads Dochedahl; Balslev, Ingegerd; Boesen, Lars

    2017-01-01

    INTRODUCTION: The purpose of this pilot study was to investigate whether a short prostate biparametric magnetic resonance imaging (bp-MRI) protocol provides a valuable diagnostic addition for biopsy guidance in biopsy-naive men with a suspicion of prostate cancer (PCa). METHODS: A total of 62...... biopsy-naive patients referred to a systematic transrectal ultrasound biopsy (TRUS-bx) due to suspicion of PCa were prospectively enrolled. Bp-MRI was performed before biopsy. All lesions were scored according to the modified Prostate Imaging Reporting and Data System (PI-RADS) version 2. All patients...

  12. Analysis of costs of transrectal prostate biopsy.

    Science.gov (United States)

    Fandella, Andrea

    2011-01-01

    Literature reports mortality and morbidity data from prostatic carcinoma which permit a better use of some routine diagnostic tools such as transrectal ultrasound-guided biopsy. The aim of this work is to quantify the overall cost of transrectal ultrasound biopsy of the prostate (TRUSB) and to assess the economic impact of current procedures for diagnosing prostatic carcinoma. The total cost of TRUSB was calculated with reference to 247 procedures performed in 2008. The following cost factors were evaluated: personnel, materials, maintenance/depreciation of the equipment, energy consumption, and hospital overheads. A literature review was also carried out to check if our extrapolated costs corresponded to those of other authors worldwide, and to consider them in the wider framework of the economic effectiveness of strategies for early diagnosis of cancer of the prostate. The overall cost of TRUSB (8 samples) was EUR 249,000, obtained by adding together the costs of: personnel (EUR 160,000); materials (EUR 59,000); equipment maintenance and depreciation (EUR 12,400); energy consumption (EUR0,1); hospital overheads (EUR 17,500). With extended or saturation biopsies the cost increases for the more time needed by pathologists and can be calculated as EUR 300,000. The literature review points out TRUSB as an invasive tool for diagnosing prostatic carcinoma, clinically and economically controversial. Post-mortem data report the presence of cancer cells in the prostate of 50% of 70-year-old men, while extrapolations calculate a morbidity rate from prostatic carcinoma in 9.5% of 50-year-old men. It is therefore obvious that randomized prostatic biopsies, methods apart, have a good probability of being positive. This probability varies with the patient's age, the level of prostate specific antigen (PSA), the density of PSA/cm3 of prostate volume (PSAD), and the detection by digital exploration and/or positive transrectal ultrasound. CONCLUSIONS. Despite the severe

  13. Multiparty Session Types as Coherence Proofs

    DEFF Research Database (Denmark)

    Carbone, Marco; Montesi, Fabrizio; Schürmann, Carsten

    2015-01-01

    We propose a Curry-Howard correspondence between a language for programming multiparty sessions and a generalisation of Classical Linear Logic (CLL). In this framework, propositions correspond to the local behaviour of a participant in a multiparty session type, proofs to processes, and proof...... normalisation to executing communications. Our key contribution is generalising duality, from CLL, to a new notion of n-ary compatibility, called coherence. Building on coherence as a principle of compositionality, we generalise the cut rule of CLL to a new rule for composing many processes communicating...... in a multiparty session. We prove the soundness of our model by showing the admissibility of our new rule, which entails deadlock-freedom via our correspondence....

  14. Intersections and Unions of Session Types

    Directory of Open Access Journals (Sweden)

    Coşku Acay

    2017-02-01

    Full Text Available Prior work has extended the deep, logical connection between the linear sequent calculus and session-typed message-passing concurrent computation with equi-recursive types and a natural notion of subtyping. In this paper, we extend this further by intersection and union types in order to express multiple behavioral properties of processes in a single type. We prove session fidelity and absence of deadlock and illustrate the expressive power of our system with some simple examples. We observe that we can represent internal and external choice by intersection and union, respectively, which was previously suggested by Padovani for a different language of session types motivated by operational rather than logical concerns.

  15. Instruments for documentation of music therapy sessions

    DEFF Research Database (Denmark)

    Ridder, Hanne Mette Ochsner

    It is an important part of the clinical music therapy work to document the daily sessions. For the clinician it is necessary to have a brief overview of each session in order to assess the methods and the process, and not least to be able to give clear reports of these issues to other health care...... professionals at staff meetings, conferences, etc. For music therapists with many clients there is not time enough during a working day to provide comprehensive process descriptions in the music therapy log. Therefore instruments that help the clinician in reducing and structuring this information are needed....... Danish and Norwegian music therapist have collaborated on developing a one page sheet with a structured form where they after each music therapy session document their use of methods and techniques in individual music therapy with persons with dementia. With this instrument therapists have easy access...

  16. Poster session in instructional technology course

    Science.gov (United States)

    Diniaty, Artina; Fauzi'ah, Lina; Wulan Febriana, Beta; Arlianty, Widinda Normalia

    2017-12-01

    Instructional technology course must be studied by students in order to 1) understand the role of technology in learning, 2) capable of analyzing advantages and disadvantages of using technology in teaching, 3) capable of performing technology in teaching. A poster session in instructional technology course was performed to 1) enhance students' interest in this course and develop students' creativity. The step of this research includes: planning, implementation, and evaluation. The result showed that students' responses towards poster session in instructional technology course were good.

  17. Summary of Session 2 "Machine Studies"

    CERN Document Server

    Assmann, R W

    2012-01-01

    This document summarizes the talks and discussion that took place in the second session of the Chamonix 2012 workshop concerning results from machine studies performed in 2011. The session consisted of the following presentations: “LHC experience with different bunch spacings” by G. Rumolo; “Observations of beam-beam effects in MDs in 2011” by W. Herr; “Beam-induced heating/ bunch length/RF and lessons for 2012” by E. Metral; “Lessons in beam diagnostics” by R. Jones; “Quench margins” by M. Sapinski; “First demonstration with beam of the Achromatic Telescopic Squeeze (ATS)” by S. Fartoukh.

  18. Summary of Session 2 'Machine Studies'

    Energy Technology Data Exchange (ETDEWEB)

    Assmann, R W; Papotti, G [European Organization for Nuclear Research, Geneva (Switzerland)

    2012-07-01

    This document summarizes the talks and discussion that took place in the second session of the Chamonix 2012 workshop concerning results from machine studies performed in 2011. The session consisted of the following presentations: “LHC experience with different bunch spacings” by G. Rumolo; “Observations of beam-beam effects in MDs in 2011” by W. Herr; “Beam-induced heating/ bunch length/RF and lessons for 2012” by E. Metral; “Lessons in beam diagnostics” by R. Jones; “Quench margins” by M. Sapinski; “First demonstration with beam of the Achromatic Telescopic Squeeze (ATS)” by S. Fartoukh. (author)

  19. PSA velocity does not aid the detection of prostate cancer in men with a prior negative biopsy: data from the European Randomized Study of Prostate Cancer Screening in Göteborg, Sweden and Rotterdam, Netherlands

    Science.gov (United States)

    Vickers, Andrew J.; Wolters, Tineke; Savage, Caroline J.; Cronin, Angel M.; O’Brien, M. Frank; Roobol, Monique J.; Aus, Gunnar; Scardino, Peter T.; Hugosson, Jonas; Schröder, Fritz H.; Lilja, Hans

    2012-01-01

    Purpose Prostate specific antigen (PSA) velocity has been proposed as a marker to aid detection of prostate cancer. We sought to determine whether PSA velocity could predict the results of repeat biopsy in men with persistently elevated PSA after initial negative biopsy. Materials and Methods We identified 1,837 men who participated in the Göteborg or Rotterdam section of the European Randomized Screening study of Prostate Cancer (ERSPC), and who had one or more subsequent prostate biopsies after an initial negative finding. We evaluated whether PSA velocity improved predictive accuracy beyond that of PSA alone. Results There were a total of 2579 repeat biopsies, of which 363 (14%) were positive for prostate cancer, and 44 (1.7%) were high grade (Gleason score ≥7). Although PSA velocity was statistically associated with cancer risk (p<0.001), it had very low predictive accuracy (area-under-the-curve [AUC] of 0.55). There was some evidence that PSA velocity improved AUC compared to PSA for high grade cancer. However, the small increase in risk associated with high PSA velocity – from 1.7 % to 2.8% as velocity increased from 0 to 1 ng / ml / year - is of questionable clinical relevance. Conclusions Men with a prior negative biopsy have a lower risk for prostate cancer at subsequent biopsies, with high grade disease particularly rare. We found little evidence to support the use of PSA velocity to aid decisions about repeat biopsy for prostate cancer. PMID:20643434

  20. Sedation as an alternative method to lessen patient discomfort due to transrectal ultrasonography-guided prostate biopsy

    International Nuclear Information System (INIS)

    Turgut, A.T.; Ergun, E.; Kosar, U.; Kosar, P.; Ozcan, A.

    2006-01-01

    Background: Despite being highly efficient for the relief of patient discomfort due to transrectal ultrasound (TRUS) guided prostate biopsy, periprostatic anesthesia is occasionally reported to be of limited use. We aimed to evaluate the efficacy of conscious sedation, an accepted method for lessening patient discomfort due to interventional radiological procedures and compare it with periprostatic anesthesia. Methods: 93 candidates for biopsy were randomised to three groups: group 1 (n = 31) received intravenous midazolam, group 2 (n = 31) received periprostatic lidocaine injection, whereas group 3 (n = 31) received no anesthetic before the procedure. After the biopsy patients were asked to express discomfort by visual anologue scale (VAS). Results: The mean scores for groups 1 and 2 were significantly lower than that of group 3 (1.4 ± 1.1 and 2.0 ± 1.5 versus 4.7 ± 1.6, respectively; p < 0.05 for both). For patients with VAS scores exceeding 4 (moderate to severe discomfort), a significant difference was calculated between groups 1 and 2 (3% versus 29%, p < 0.05) and between each and group 3 (3% and 29% versus 80%, respectively; p < 0.05 for each). Conclusions: Sedation is an alternative for increasing patient comfort during TRUS-guided prostate biopsy, especially in clinical situations like patient anxiety, young age, repeat biopsies or inflammatory anal diseases

  1. [Breast cancer: histological prognosis from biopsy material].

    Science.gov (United States)

    Veith, F; Picco, C

    1977-01-01

    Two histological factors to be taken into consideration for prognosis in pretreatment schedules of breast cancer have been studied on a group of 352 cases treated by non-mutilating therapeutics at the Fondation Curie between 1960 and 1970. The tumour material the slides of which we have reexamined "blindly", i.e. ignoring the evolution of the case had been obtained mostly by drill-biopsy. Histological groups and types have been determined following an analytical classification for computer purpose. The degree of malignancy was calculated with the method of Scarff-Bloom-Richardson. The analyzed data have been memorized on computer and then confronted with the elements of the T.N.M. classification and the survival of the patients involved. It appeared that if drill-biopsie have been performed correctly the histological type may be defined in eighty percent of cases. And it is likewise possible to calculate the histological grade of malignancy for each mammary cancer. With such a material the value for prognosis by means of the Scarff-Bloom-Richardson method still remains if applied only to adenocarcinoma of the "common infiltrating type".

  2. Dengue: muscle biopsy findings in 15 patients

    Directory of Open Access Journals (Sweden)

    S.M.F. Malheiros

    1993-06-01

    Full Text Available Dengue is known to produce a syndrome involving muscles, tendons and joints. The hallmark of this syndrome is severe myalgia but includes fever, cutaneous rash, and headache. The neuromuscular aspects of this infection are outlined only in isolated reports, and the muscle histopathological features during myalgia have not been described. In order to ascertain the actual neuromuscular involvement in dengue and better comprehend the histological nature of myalgia, we performed a clinical and neurological evaluation, a serum CPK level and a muscle biopsy (with histochemistry in 15 patients (4 males, median age 23 years (range 14-47 with classic dengue fever, serologically confirmed, during the bra-zilian dengue epidemics from September 1986 to March 1987. All patients had a history of fever, headache and severe myalgia. Upon examination 4 had a cutaneous rash, 3 had fever, and 3 a small hepatomegaly. The neurological examination was unremarkable in all and included a manual muscle test. CPK was mildly elevated in only 3 patients. Muscle biopsy revealed a light to moderate perivascular mononuclear infiltrate in 12 patients and lipid accumulation in 11. Mild mitochondrial proliferation was seen in 3, few central nuclei in 3, rare foci of myonecrosis in 3, and 2 patients had type grouping. Dengue in our patients, produced myalgia but no detectable muscle weakness or other neuromuscular involvement. The main histopathological correlation with myalgia seems to be a perivascular mononuclear infiltrate and lipid accumulation.

  3. Endometrial biopsy findings in postmenopausal bleeding

    International Nuclear Information System (INIS)

    Sarfraz, T.; Tariq, H.

    2007-01-01

    To study endometrial histopathology in women presenting with postmenopausal bleeding. A two-year study from January 2003 to December 2004 of 100 cases of postmenopausal bleeding was conducted at Combined Military Hospital, Sialkot. The histopathology of endometrial biopsy specimens was done to find out the causes of postmenopausal bleeding in these ladies. All these 100 patients had confirmed menopause and the average age was 55 years and above. The most common histopathological diagnosis was senile endometrial atrophy (27%), followed by simple cystic hyperplasia in (17%). Three cases of simple cystic hyperplasia had coexistent ovarian tumors. Glandular hyperplasia without atypia was seen in 6% and with atypia in 4%. Other causes were endometritis (13%), endometrial polyps (8%), proliferative phase endometrium (6%) and secretary phase endometrium (5%). Endometrial carcinoma was seen in (6%) cases, (8%) biopsy specimens were non-representative. Although senile endometrial atrophy was most commonly found in these ladies but a significant percentage of endometrial hyperplasia and endometrial cancer implies the need for investigating all cases of postmenopausal bleeding. Bimanual examination and pelvic ultrasonography should be combined with endometrial sampling so that rare pelvic pathologies may not be missed. (author)

  4. The value of 18F-choline PET/CT in patients with elevated PSA-level and negative prostate needle biopsy for localisation of prostate cancer

    International Nuclear Information System (INIS)

    Igerc, I.; Kohlfuerst, S.; Gallowitsch, H.J.; Matschnig, S.; Kresnik, E.; Gomez-Segovia, I.; Lind, P.

    2008-01-01

    Patients with persistent elevated PSA and repeated negative prostate biopsy, that means having the prostate biopsied at multiple times, were investigated with 18F-choline PET/CT to delineate prostate cancer and guide renewed prostate biopsy. Twenty patients with elevated PSA and negative prostate biopsies underwent 18F-choline PET/CT. We performed an early examination of the pelvic region 3-5 min after application. After 30 minutes a whole body PET/CT examination was performed. Image analysis was performed visually and by semi-quantitative analysis calculating the maximum standardised uptake value (SUVmax). 18F-choline uptake was defined as focal, multifocal or inhomogeneous. After the 18F-choline PET/CT, all patients underwent a repeated prostate biopsy, and in the cases where a focal or multifocal uptake was found, the biopsy was guided by the result of the examination. Qualitative image analysis revealed focal 18F-choline uptake in 13 out of 20 patients. In five patients, prostate cancer was revealed by repeated aspiration biopsy. None of the patients with a multifocal or inhomogeneous 18F-choline uptake had a malignant neoplasm in the prostate. Semiquantitative analysis performed with SUVmax was not helpful in the discrimination of malignancy but showed high values also in benign prostate diseases, as well as in normal prostate tissue. The dual-phase protocol delivered no clear benefit in discriminating malignancy from benign alterations. The use of 18F-choline cannot be generally recommended for localising prostate cancer; however, in highly selected patients, we found useful additional information. In 25% of patients, 18F-choline PET/CT allowed the identification of neoplastic prostatic zones. (orig.)

  5. Undergraduate Seminars: The Poster Session Solution.

    Science.gov (United States)

    Chute, Douglas L.; Bank, Barry

    1983-01-01

    A good alternative to the undergraduate psychology seminar is the poster session. During the course each student wrote a review paper. For use in his/her class presentation, the student provided the following information on poster paper: title, author, abstract, a few graphs or illustrations from the literature, conclusions, and references. (RM)

  6. IAEA General Conference begins annual session

    International Nuclear Information System (INIS)

    2001-01-01

    The document gives general information about the opening and the programme of the 45th regular session of the IAEA General Conference (17-21 September 2001, Austria Center Vienna). The conference is attended by ministers and high-level governmental representatives from 132 Member States of the IAEA

  7. IAEA General Conference begins annual session

    International Nuclear Information System (INIS)

    2000-01-01

    The document gives general information about the opening and the programme of the 44th regular session of the IAEA General Conference (18 -22 September 2000, Austria Center Vienna). The conference is attended by ministers and high-level governmental representatives from 130 Member States of the IAEA

  8. Declarative interpretations of session-based concurrency

    DEFF Research Database (Denmark)

    Cano, Mauricio; Rueda, Camilo; López-Acosta, Hugo-Andrés

    2015-01-01

    Session-based concurrency is a type-based approach to the analysis of communication-intensive systems. Correct behavior in these systems may be specified in an operational or declarative style: the former defines how interactions are structured; the latter defines governing conditions...

  9. Working session 4: Preventative and corrective measures

    International Nuclear Information System (INIS)

    Clark, R.; Slama, G.

    1997-01-01

    The Preventive and Corrective Measures working session included 13 members from France, Germany, Japan, Spain, Slovenia, and the United States. Attendee experience included regulators, utilities, three steam generator vendors, consultants and researchers. Discussions centered on four principal topics: (1) alternate materials, (2) mechanical mitigation, (3) maintenance, and (4) water chemistry. New or replacement steam generators and original equipment steam generators were separately addressed. Four papers were presented to the session, to provide information and stimulate various discussion topics. Topics discussed and issues raised during the several meeting sessions are provided below, followed by summary conclusions and recommendations on which the group was able to reach a majority consensus. The working session was composed of individuals with diverse experience and varied areas of specialized expertise. The somewhat broad range of topics addressed by the group at times saw discussion participation by only a few individuals. As in any technical meeting where all are allowed the opportunity to speak their mind, straying from an Individual topic was not unusual. Where useful, these stray topics are also presented below within the context In which they occurred. The main categories of discussion were: minimize sludge; new steam generators; maintenance; mechanical mitigation; water chemistry

  10. 9. Biennial session of nuclear physics

    International Nuclear Information System (INIS)

    1987-03-01

    As every two years the 9th biennial session of nuclear physics shall try to make a survey of the recent experimental developments as well as the evolution of the theoretical ideas in Nuclear Physics. Communications are indexed and analysed separately

  11. Summary of the Relativistic Heavy Ion Sessions

    International Nuclear Information System (INIS)

    Harris, J.W.

    1988-07-01

    This paper briefly discusses the topics covered in the relativistic heavy ion in sessions. The prime motivation for these investigations is the possibility of forming quark matter, therefore the formation of a quark-gluon plasma. Topics on suppression of J//psi/ production, th equation of state of nuclear matter, transverse energy distributions and two pion interferometry techniques are discussed. 38 refs

  12. An Erlang Implementation of Multiparty Session Actors

    Directory of Open Access Journals (Sweden)

    Simon Fowler

    2016-08-01

    Full Text Available By requiring co-ordination to take place using explicit message passing instead of relying on shared memory, actor-based programming languages have been shown to be effective tools for building reliable and fault-tolerant distributed systems. Although naturally communication-centric, communication patterns in actor-based applications remain informally specified, meaning that errors in communication are detected late, if at all. Multiparty session types are a formalism to describe, at a global level, the interactions between multiple communicating entities. This article describes the implementation of a prototype framework for monitoring Erlang/OTP gen_server applications against multiparty session types, showing how previous work on multiparty session actors can be adapted to a purely actor-based language, and how monitor violations and termination of session participants can be reported in line with the Erlang mantra of "let it fail". Finally, the framework is used to implement two case studies: an adaptation of a freely-available DNS server, and a chat server.

  13. Posters. [Poster Session at AHRD Conference, 2001].

    Science.gov (United States)

    2001

    The first of the papers in this poster session, "Developing the Employment Brand: Targeting MBA Campus Hires" (Diane M. Bergeron), posits that employment branding benefits both individuals and organizations. It functions as a campus recruiting tool in a competitive labor market and communicates the organization's values and work…

  14. Short term outcomes of prostate biopsy in men tested for cancer by prostate specific antigen: prospective evaluation within ProtecT study.

    Science.gov (United States)

    Rosario, Derek J; Lane, J Athene; Metcalfe, Chris; Donovan, Jenny L; Doble, Andy; Goodwin, Louise; Davis, Michael; Catto, James W F; Avery, Kerry; Neal, David E; Hamdy, Freddie C

    2012-01-09

    To measure the effect of the adverse events within 35 days of transrectal ultrasound guided biopsy from the perspective of asymptomatic men having prostate specific antigen (PSA) testing; to assess early attitude to re-biopsy; to estimate healthcare resource use associated with adverse events due to biopsy; and to develop a classification scheme for reporting adverse events after prostate biopsy. Prospective cohort study (Prostate Biopsy Effects: ProBE) nested within Prostate Testing for Cancer and Treatment (ProtecT) study. Participants Between 1999 and 2008, 227,000 community dwelling men aged 50-69 years were identified at 352 practices and invited to counselling about PSA testing. 111,148 attended a nurse led clinic in the community, and 10,297 with PSA concentrations of 3-20 ng/mL were offered biopsy within ProtecT. Between February 2006 and May 2008, 1147/1753 (65%) eligible men (mean age 62.1 years, mean PSA 5.4 ng/mL) having 10 core transrectal ultrasound guided biopsy under antibiotic cover in the context of ProtecT were recruited to the ProBE study. Purpose designed questionnaire administered at biopsy and 7 and 35 days after the procedure to measure frequency and effect of symptoms related to pain, infection, and bleeding; patients' attitude to repeat biopsy assessed immediately after biopsy and 7 days later; participants' healthcare resource use within 35 days of biopsy evaluated by questionnaire, telephone follow-up, and medical note review; each man's adverse event profile graded according to symptoms and healthcare use. Pain was reported by 429/984 (43.6%), fever by 172/985 (17.5%), haematuria by 642/976 (65.8%), haematochezia by 356/967 (36.8%), and haemoejaculate by 605/653 (92.6%) men during the 35 days after biopsy. Fewer men rated these symptoms as a major/moderate problem-71/977 (7.3%) for pain, 54/981 (5.5%) for fever, 59/958 (6.2%) for haematuria, 24/951 (2.5%) for haematochezia, and 172/646 (26.6%) for haemoejaculate. Immediately after

  15. Acute caffeine effect on repeatedly measured P300

    OpenAIRE

    Pan, Jingbo; Takeshita, Tatsuya; Morimoto, Kanehisa

    2000-01-01

    The acute effect of a single-dose of caffeine on the P300 event-related brain potential (ERP) was assessed in a study using a repeatedly presented auditory oddball button-press task. A dose (5mg/kg body-weight) of either caffeine or placebo lactose, dissolved in a cup of decaffeinated coffee, was administered double-blindly to coffee drinkers who had abstained from coffee for 24hrs, with the presentation order of the sessions counterbalanced and separated by 2–4 weeks. The caffeine-treatment ...

  16. Repeated cue exposure effects on subjective and physiological indices of chocolate craving

    NARCIS (Netherlands)

    van Gucht, D.; Vansteenwegen, D.; Beckers, T.; Hermans, D.; Baeyens, F.; Van den Bergh, O.

    2008-01-01

    The aim of this study is to investigate the effects of repeated unreinforced exposure to chocolate cues in persons reporting chocolate craving. Participants in the experimental group (n ¼ 40) received 10 consecutive brief exposures to chocolate cues in each of two sessions, separated by 1-3 days.

  17. Repeated dose titration versus age-based method in electroconvulsive therapy: a pilot study

    NARCIS (Netherlands)

    Aten, J.J.; Oudega, M.L.; van Exel, E.; Stek, M.L.; van Waarde, J.A.

    2015-01-01

    In electroconvulsive therapy (ECT), a dose titration method (DTM) was suggested to be more individualized and therefore more accurate than formula-based dosing methods. A repeated DTM (every sixth session and dose adjustment accordingly) was compared to an age-based method (ABM) regarding treatment

  18. Repeated E-Book Reading and Its Contribution to Learning New Words among Kindergartners

    Science.gov (United States)

    Korat, Ofra; Kozlov-Peretz, Olla; Segal-Drori, Ora

    2017-01-01

    The contribution of repeated e-book reading with and without word explanation support and its effect on receptive and expressive word learning among preschoolers was examined. Seventy-eight kindergartners were randomly divided into an experimental and a control group. The experimental group received two individual reading sessions of an e-book…

  19. Effects of percutaneous needle liver biopsy on dairy cow behaviour

    DEFF Research Database (Denmark)

    Mølgaard, Lene; Damgaard, Birthe Marie; Bjerre-Harpøth, Vibeke

    2012-01-01

    In cattle, percutaneous needle liver biopsy is used for scientific examination of liver metabolism. The impact of the biopsy procedure is, however, poorly investigated. Our aim was to examine the behaviour of dairy cows during and after liver biopsy. Data were collected from 18 dry cows....... Percutaneous needle liver biopsies (after administration of local anaesthesia (2% Procaine)) and blood samples were taken during restraining. During the control treatment, animals were restrained and blood sampled. During the biopsy procedure, cows showed increased restlessness (P = 0.008), frequency of head...... behavioural changes for up to 19 h – and particularly for behaviour previously associated with pain. Even though the exact welfare impact of percutaneous needle liver biopsies in cows is not known, and the magnitude of the behavioural changes was limited, pain always has negative effects on animal welfare...

  20. Session-RPE for quantifying load of different youth taekwondo training sessions.

    Science.gov (United States)

    Lupo, Corrado; Capranica, Laura; Cortis, Cristina; Guidotti, Flavia; Bianco, Antonino; Tessitore, Antonio

    2017-03-01

    The session rating of perceived exertion (session-RPE) proved to be a valuable method to quantify the internal training load (ITL) in taekwondo. However, no study validated this method in youth taekwondo athletes performing different training sessions. Thus this study aimed at evaluating the reliability of the session-RPE to monitor the ITL of prepubescent taekwondo athletes during pre-competitive (PC) and competitive (C) training sessions. Five female (age: 12.0±0.7 y; height: 1.54±0.08 m; body mass: 48.8±7.3 kg) and four male (age: 12.0±0.8 yrs; height: 1.55±0.07 m; body mass: 47.3±5.3 kg) taekwondo athletes were monitored during 100 individual sessions (PC: N.=33; C: N.=67). The Edwards' HR method was used as reference measure of ITL; the CR-10 RPE scale was administered at 1- and 30-minutes from the end of each session. No difference for gender emerged. The ITLs of C (Edwards: 228±40 arbitrary units, AU) resulted higher than that of PC (192±26 AU; P=0.04). Although all training typologies and data collections achieved significant correlations between Edwards' and session-RPE methods, a large relationship (r =0.71, Psessions evaluated at 30 minutes of the recovery phases. Findings support coaches of prepubescent taekwondo athletes to successfully use session-RPE to monitor the ITL of different training typologies. However, PC training evaluated at 30 minutes of the recovery phase represents the best condition for a highly reliable ITL perception.

  1. Hysteresis of magnetostructural transitions: Repeatable and non-repeatable processes

    Science.gov (United States)

    Provenzano, Virgil; Della Torre, Edward; Bennett, Lawrence H.; ElBidweihy, Hatem

    2014-02-01

    The Gd5Ge2Si2 alloy and the off-stoichiometric Ni50Mn35In15 Heusler alloy belong to a special class of metallic materials that exhibit first-order magnetostructural transitions near room temperature. The magnetic properties of this class of materials have been extensively studied due to their interesting magnetic behavior and their potential for a number of technological applications such as refrigerants for near-room-temperature magnetic refrigeration. The thermally driven first-order transitions in these materials can be field-induced in the reverse order by applying a strong enough field. The field-induced transitions are typically accompanied by the presence of large magnetic hysteresis, the characteristics of which are a complicated function of temperature, field, and magneto-thermal history. In this study we show that the virgin curve, the major loop, and sequentially measured MH loops are the results of both repeatable and non-repeatable processes, in which the starting magnetostructural state, prior to the cycling of field, plays a major role. Using the Gd5Ge2Si2 and Ni50Mn35In15 alloys, as model materials, we show that a starting single phase state results in fully repeatable processes and large magnetic hysteresis, whereas a mixed phase starting state results in non-repeatable processes and smaller hysteresis.

  2. Hysteresis of magnetostructural transitions: Repeatable and non-repeatable processes

    International Nuclear Information System (INIS)

    Provenzano, Virgil; Della Torre, Edward; Bennett, Lawrence H.; ElBidweihy, Hatem

    2014-01-01

    The Gd 5 Ge 2 Si 2 alloy and the off-stoichiometric Ni 50 Mn 35 In 15 Heusler alloy belong to a special class of metallic materials that exhibit first-order magnetostructural transitions near room temperature. The magnetic properties of this class of materials have been extensively studied due to their interesting magnetic behavior and their potential for a number of technological applications such as refrigerants for near-room-temperature magnetic refrigeration. The thermally driven first-order transitions in these materials can be field-induced in the reverse order by applying a strong enough field. The field-induced transitions are typically accompanied by the presence of large magnetic hysteresis, the characteristics of which are a complicated function of temperature, field, and magneto-thermal history. In this study we show that the virgin curve, the major loop, and sequentially measured MH loops are the results of both repeatable and non-repeatable processes, in which the starting magnetostructural state, prior to the cycling of field, plays a major role. Using the Gd 5 Ge 2 Si 2 and Ni 50 Mn 35 In 15 alloys, as model materials, we show that a starting single phase state results in fully repeatable processes and large magnetic hysteresis, whereas a mixed phase starting state results in non-repeatable processes and smaller hysteresis

  3. Long lasting effects of daily theta burst rTMS sessions in the human amblyopic cortex.

    Science.gov (United States)

    Clavagnier, Simon; Thompson, Benjamin; Hess, Robert F

    2013-11-01

    It has been reported that a single session of 1 Hz or 10 Hz repetitive transcranial magnetic stimulation (rTMS) of the visual cortex can temporarily improve contrast sensitivity in adults with amblyopia. More recently, continuous theta burst stimulation (cTBS) of the visual cortex has been found to improve contrast sensitivity in observers with normal vision. The aims of this study were to assess whether cTBS of the visual cortex could improve contrast sensitivity in adults with amblyopia and whether repeated sessions of cTBS would lead to more pronounced and/or longer lasting effects. cTBS was delivered to the visual cortex while patients viewed a high contrast stimulus with their non-amblyopic eye. This manipulation was designed to bias the effects of cTBS toward inputs from the amblyopic eye. Contrast sensitivity was measured before and after stimulation. The effects of one cTBS session were measured in five patients and the effects of five consecutive daily sessions were measured in four patients. Three patients were available for follow-up at varying intervals after the final session. cTBS improved amblyopic eye contrast sensitivity to high spatial frequencies (P enduring visual function improvements in adults with amblyopia. Copyright © 2013 Elsevier Inc. All rights reserved.

  4. Image-guided pleural biopsy: diagnostic yield and complications

    International Nuclear Information System (INIS)

    Benamore, R.E.; Scott, K.; Richards, C.J.; Entwisle, J.J.

    2006-01-01

    Background: Pleural biopsy and cytology are standard procedures for the investigation of pleural disease. Recent medical literature has suggested that image-guided pleural biopsy shows improved sensitivity for the diagnosis of pleural malignancy, when compared with the more commonly performed reverse bevel needle biopsy such as Abrams' needle. In our centre there has been an increasing trend towards performing image-guided pleural biopsies, and to our knowledge there is no large published series documenting the complication rate and diagnostic yield. Methods: The radiology and pathology databases were searched for all image-guided [computed tomography (CT) and ultrasound (US)] pleural biopsies from January 2001 to December 2004. All imaging and histology were reviewed, and final diagnostic information about patients was obtained from the respiratory multidisciplinary team database and patient notes. A record was made of complications following biopsy, presence of pleura in the biopsy, and adequacy of tissue for histological diagnosis. Results: A total of 82 patients underwent 85 image-guided pleural biopsies over a 4-year period. 80 cases were performed under CT and five under US guidance. The rate of new pneumothorax detected by chest radiography was 4.7%. No patient required a chest drain or blood transfusion to treat complications. In 10 (12%) cases, there was inadequate tissue to reach a confident histological diagnosis and in eight (9%) of these, no pleura was present. Assuming all suspicious and inadequate biopsies are treated as benign, which is the worst case scenario, image-guided pleural biopsy has a sensitivity and specificity of 76% and 100%, respectively, for the diagnosis of malignant disease. Conclusions: Image-guided pleural biopsy is a safe procedure with few associated complications and has a higher sensitivity than previously published series for reverse cutting needle biopsy in the diagnosis of malignant pleural disease

  5. Image-guided pleural biopsy: diagnostic yield and complications

    Energy Technology Data Exchange (ETDEWEB)

    Benamore, R.E. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom)]. E-mail: rachelbenamore@doctors.org.uk; Scott, K. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom); Richards, C.J. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom); Entwisle, J.J. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom)

    2006-08-15

    Background: Pleural biopsy and cytology are standard procedures for the investigation of pleural disease. Recent medical literature has suggested that image-guided pleural biopsy shows improved sensitivity for the diagnosis of pleural malignancy, when compared with the more commonly performed reverse bevel needle biopsy such as Abrams' needle. In our centre there has been an increasing trend towards performing image-guided pleural biopsies, and to our knowledge there is no large published series documenting the complication rate and diagnostic yield. Methods: The radiology and pathology databases were searched for all image-guided [computed tomography (CT) and ultrasound (US)] pleural biopsies from January 2001 to December 2004. All imaging and histology were reviewed, and final diagnostic information about patients was obtained from the respiratory multidisciplinary team database and patient notes. A record was made of complications following biopsy, presence of pleura in the biopsy, and adequacy of tissue for histological diagnosis. Results: A total of 82 patients underwent 85 image-guided pleural biopsies over a 4-year period. 80 cases were performed under CT and five under US guidance. The rate of new pneumothorax detected by chest radiography was 4.7%. No patient required a chest drain or blood transfusion to treat complications. In 10 (12%) cases, there was inadequate tissue to reach a confident histological diagnosis and in eight (9%) of these, no pleura was present. Assuming all suspicious and inadequate biopsies are treated as benign, which is the worst case scenario, image-guided pleural biopsy has a sensitivity and specificity of 76% and 100%, respectively, for the diagnosis of malignant disease. Conclusions: Image-guided pleural biopsy is a safe procedure with few associated complications and has a higher sensitivity than previously published series for reverse cutting needle biopsy in the diagnosis of malignant pleural disease.

  6. Seven cases of upper gastrointestinal bleeding after cold biopsy

    OpenAIRE

    Alneaimi, Khaled; Abdelmoula, Ali; Vincent, Magalie; Savale, Camille; Baye, Birane; Lesur, Gilles

    2016-01-01

    Background and study aims: Routine biopsy of the upper gastrointestinal tract is performed with increasing frequency. It is generally considered to be safe without significant complication. However, gastrointestinal bleeding as a result of cold biopsy is a known complication. We report seven cases of upper gastrointestinal bleeding after cold biopsy and discuss clinical data, risks factors, severity and management of this event. We suggest that physicians must be more cautious with this rare ...

  7. Ultrasound guided pleural biopsy in undiagnosed exudative pleural effusion patients

    OpenAIRE

    Adel S. Ahmed; Mostafa I. Ragab; Alaa eldin M. Elgazaar; Nagwan A. Ismail

    2016-01-01

    Introduction: Pleural biopsy for pathological confirmation is the standard diagnostic procedure for pleural diseases, transthoracic ultrasonography (TUS) has evolved as an important imaging tool for diagnosing pleural and pulmonary conditions. Aim of the study: To assess the diagnostic yield of TUS guided pleural biopsy versus both CT guided and thoracoscopic pleural biopsy in the diagnosis of undiagnosed exudative pleural effusion. Patients and methods: The study was conducted at chest...

  8. Poster Sessions in Marketing Education: An Empirical Examination

    Science.gov (United States)

    Stegemann, Nicole; Sutton-Brady, Catherine

    2009-01-01

    Poster sessions provide a creative and stimulating alternative to traditional assessment methods in marketing. Poster sessions, as a means of assessment, have long been used in science fields. This article presents the successful implementation of poster sessions as a means of assessment in a postgraduate unit of study. Poster sessions in…

  9. Graph Transformation for Consolidation of Creativity Sessions Results

    DEFF Research Database (Denmark)

    Dolog, Peter

    2010-01-01

    Graph transformation approach for consolidation of creativity sessions results is part of the FP7 EU/IST project idSpace: Tooling of and training for collaborative, distributed product innovation. The goal of graph transformation approach is to provide a tool for merging results of various sessions...... (such as brainstorming sessions), which are represented as graphs, when the session participants- are physically distributed....

  10. Effect of Repeated Food Morsel Splitting on Jaw Muscle Control

    DEFF Research Database (Denmark)

    A, Kumar; Svensson, Krister G; Baad-Hansen, Lene

    2014-01-01

    Mastication is a complex motor task often initiated by splitting of the food morsel between the anterior teeth. Training of complex motor tasks has consistently been shown to trigger neuroplastic changes in corticomotor control and optimization of muscle function. It is not known if training...... and repeated food morsel splitting lead to changes in jaw muscle function. Objective: To investigate if repeated splitting of food morsels in participants with natural dentition changes the force and jaw muscle electromyographic (EMG) activity. Methods: Twenty healthy volunteers (mean age = 26.2 ± 3.9 years......) participated in a single one-hour session divided into six series. Each series consisted of ten trials of a standardized behavioral task (total of 60 trials). The behavioral task was to hold and split a food morsel (8 mm, 180 mg placebo tablet) placed on a bite force transducer with the anterior teeth...

  11. Towards the mid-infrared optical biopsy

    DEFF Research Database (Denmark)

    Seddon, Angela B.; Benson, Trevor M.; Sujecki, Slawomir

    2016-01-01

    We are establishing a new paradigm in mid-infrared molecular sensing, mapping and imaging to open up the mid-infrared spectral region for in vivo (i.e. in person) medical diagnostics and surgery. Thus, we are working towards the mid-infrared optical biopsy ('opsy' look at, bio the biology) in situ...... in the body for real-time diagnosis. This new paradigm will be enabled through focused development of devices and systems which are robust, functionally designed, safe, compact and cost effective and are based on active and passive mid-infrared optical fibers. In particular, this will enable early diagnosis...... of a bright mid-infrared wideband source in a portable package as a first step for medical fiber-based systems operating in the mid-infrared. Moreover, mid-infrared molecular mapping and imaging is potentially a disruptive technology to give improved monitoring of the environment, energy efficiency, security...

  12. Brain biopsy for diagnosis of chlamydia encephalitis

    Directory of Open Access Journals (Sweden)

    I. A. Voznyuk

    2017-01-01

    Full Text Available This is the case of encephalitis associated with chlamydia infection of central nervous system. The diagnostic protocol of the patient included: a careful observation of somatic and neurological status, laboratory tests of blood and cerebrospinal fluid, neurovisualization. The results of the diagnostic protocol suggest that laboratory tests blood and cerebrospinal fluid possess low sensitivity and specificity. The MRI study has revealed the localization and inflammatory character of the changes in brain tissue; it has also helped to choose the most favorable area for the stereotaxic biopsy. The obtained tissue was evaluated by means of light (immunohistochemistry and electronic microscopy. The active chlamydia infection was estimated. The subsequent antibacterial etiotropic therapy resulted in the regression of the neurologic symptoms and remission.The intravitalpathomorphology study of the brain could be recommended for the management of the severe encephalitis of the unknown origin. 

  13. The efficacy of an ultrasound-guided core needle biopsy with an 18G cutting needle for the diagnosis of pancreatic diseases

    International Nuclear Information System (INIS)

    Jung, Sung Hwa; Park, Won Kyu; Chang, Jay Chun; Kim, Jae Woon; Cho, Jae Ho; Jang, Han Won; Lee, Jae Kyo; Choi, Joon Hyuk

    2008-01-01

    The objective of this study is to evaluate the efficacy and safety of an ultrasound-guided core needle biopsy with an 18G cutting needle in patients suspected of having a pancreatic disease by analyzing the diagnostic performance and complication rate. The study population comprised 35 consecutive patients who underwent an ultrasound-guided core needle biopsy using a high-speed biopsy gun accompanied with an 18G cutting-type needle between May of 2001 and October of 2005. The diagnostic performance (i.e., the acquisition rate and diagnostic accuracy) and complications associated with core needle biopsies were evaluated for its efficacy and safety. Thirty-six sessions of ultrasound-guided core needle biopsies were performed in 35 consecutive patients. All patients, except two (serous cystadenoma and autoimmune pancreatitis) were diagnosed with various subtypes of pancreatic cancer. The acquisition rate and diagnostic accuracy were 97% (35/36) and 94% (34/36), respectively. A complication occurred only in one patient (3%), which further proved to be a delayed complication (i.e., needle tract implantation). According to our findings, the ultrasound-guided core needle biopsy is a viable and safe method for the diagnosis of pancreatic diseases. Moreover, it enables the diagnosis of the pancreatic cancer subtype

  14. Renal biopsies in children: current practice and audit of outcomes.

    Science.gov (United States)

    Hussain, Farida; Mallik, Meeta; Marks, Stephen D; Watson, Alan R

    2010-02-01

    There is considerable variation in the way that children are prepared for and the techniques employed in a renal biopsy. There was national agreement between UK paediatric renal centres to review current practice and audit outcomes An initial questionnaire survey was undertaken and a 12-month prospective audit performed of renal biopsies against agreed standards for the number of needle passes, adequacy of biopsy material and complication rates. Eleven of 13 centres participated. Information leaflets are sent pre-biopsy in five centres with only one using play preparation. Six of 11 routinely perform biopsies as day-case (DC) procedures and 6 use general anaesthesia (GA). Real-time ultrasound is the favoured method in eight centres. Biopsies are performed by nephrologists only in four centres, nephrologists with radiologists in five and radiology alone in two. Of 531 biopsies (352 native), 31% were performed as a DC with 49% being done under GA. The standard for the number of passes of native kidneys (95%). The major complication rate was higher than the standard of biopsy was performed as a DC or inpatient procedure (P = 0.73) or when GA or sedation was used (P = 0.8). The audit highlights significant variation in clinical practice with limited use of preparation materials and DC procedures. The results have stimulated constructive debate about preparation and indications for biopsy and training issues. The audit enables centres and individuals to monitor performance.

  15. CT Guided biopsies of musculoskeletal lesions, radiological and pathologic correlation

    International Nuclear Information System (INIS)

    Hadzihasanovic, B.; Milisic, L.; Zuban, J.; Mujic, E.; Jahic, E.; Gjikolli, B.; Hasanovic, B.; Lincender-Cvijetic, L.; Jaganjac, S.

    2006-01-01

    Full text: The aim of the study is to overview our experiences in taking the CT guided biopsies of musculoskeletal lesions during the period of sixteen months, analysis of validity of samples taken and correlation with pathological findings. CT guided biopsies of musculoskeletal lesions were performed in 32 patients during the period of sixteen months (from December 2004 until March 2006). Age range was from 13 to 78 years. Majorities of the biopsies were performed with coaxial cutting needle system (14 G and 16 G) with introducers size 13 and 15 G. Bone biopsies were performed with Yamsidi needles in purpose of taking the bone cylinder. Majorities of the biopsies were performed under local anaesthesia except a thirteen years old child to whom CT guided biopsy of corpus Th 6 was performed under general anaesthesia. Two samples of tissues were sent in formalin solutions to Pathology Institute for pathological verification. In one case of musculoskeletal lesions CT guided biopsies didn't yield a representative tissue sample. We had high level of congruence between radiological and pathological findings; precise presented in the article. CT guided biopsies of musculoskeletal lesions are method of choice for pathologic verification of musculoskeletal lesions proving incomparable less risk compared to 'open' biopsy which requires operating theatre and general anaesthesia. Coaxial needle systems has shown as suitable for yielding representative tissue samples (two samples for each patient), and samples are also appropriate for immunohistochemical analysis

  16. [Determination of the 120-day post prostatic biopsy mortality rate].

    Science.gov (United States)

    Canat, G A; Duclos, A; Couray-Targe, S; Schott, A-M; Polazzi, S; Scoazec, J-Y; Berger, F; Perrin, P

    2014-06-01

    Concerning death-rates were reported following prostate biopsy but the lack of contexts in which event occurred makes it difficult to take any position. Therefore, we aimed to determine the 120-day post-biopsy mortality rate. Between 2000 and 2011, 8804 men underwent prostate biopsy in the hospice civils de Lyon. We studied retrospectively, the mortality rate after each of the 11,816 procedures. Biopsies imputability was assessed by examining all medical records. Dates of death were extracted from our local patient management database, which is updated trimestrially with death notifications from the French National Institute for Statistics and Economic Studies. In our study 42 deaths occurred within 120days after 11,816 prostate biopsies (0.36%). Of the 42 records: 9 were lost to follow-up, 3 had no identifiable cause of death, 28 had an intercurrent event ruling out prostate biopsy as a cause of death. Only 2 deaths could be linked to biopsy. We reported at most 2 deaths possibly related to prostate biopsy over 11,816 procedures (0.02%). We confirmed the fact that prostate biopsies can be lethal but this rare outcome should not be considered as an argument against prostate screening given the circumstances in which it occurs. 5. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  17. Evaluation of an endoscopic liver biopsy technique in green iguanas.

    Science.gov (United States)

    Hernandez-Divers, Stephen J; Stahl, Scott J; McBride, Michael; Stedman, Nancy L

    2007-06-15

    To establish a safe and effective endoscopic technique for collection of liver biopsy specimens from lizards by use of a 2.7-mm rigid endoscope system that is commonly available in zoologic veterinary practice. Prospective study. 11 subadult male green iguanas (Iguana iguana). Each lizard was anesthetized, and right-sided coelioscopic examination of the right liver lobe and gallbladder was performed. Three liver biopsy specimens were collected from each lizard by use of a 2.7-mm rigid endoscope and 1.7-mm (5-F) biopsy forceps. Biopsy samples were evaluated histologically for quality and crush artifact. Ten days following surgery, all iguanas were euthanatized and underwent full necropsy examination. For all 11 iguanas, the right liver lobe and gallbladder were successfully examined endoscopically, and 3 biopsy specimens of the liver were collected without complications. Mean +/- SD durations of anesthesia and surgery were 24 +/- 7 minutes and 6.8 +/- 1.0 minutes, respectively. At necropsy, there was no evidence of trauma or disease associated with the skin or muscle entry sites, liver, or any visceral structures in any iguana. All 33 biopsy specimens were considered acceptable for histologic interpretation; in most samples, the extent of crush artifact was considered minimal. By use of a 2.7-mm rigid endoscope, liver biopsy procedures can be performed safely, swiftly, and easily in green iguanas. Biopsy specimens obtained by this technique are suitable for histologic examination. For evaluation of the liver and biopsy specimen collection in lizards, endoscopy is recommended.

  18. Muscle Damage and Metabolic Responses to Repeated-Sprint Running With and Without Deceleration.

    Science.gov (United States)

    Minahan, Clare L; Poke, Daniel P; Morrison, Jaime; Bellinger, Phillip M

    2018-04-04

    Minahan, CL, Poke, DP, Morrison, J, and Bellinger, PM. Muscle damage and metabolic responses to repeated-sprint running with and without deceleration. J Strength Cond Res XX(X): 000-000, 2017-This study aimed to determine whether repeated-sprint running with deceleration aggravates markers of muscle damage or delays the recovery of performance compared with repeated-sprint running without deceleration. Fourteen male team-sport athletes performed 2 randomly ordered testing sessions on a nonmotorized treadmill with one session requiring participants to decelerate (TMd) within 4 seconds before stopping or immediately step to the side of the treadmill belt at the completion of each sprint (TMa). Peak and mean velocities, speed decrement, blood lactate concentrations, and oxygen uptake were monitored during the repeated-sprint running protocols. Countermovement vertical jump (CMJ) performance, perceived muscle soreness, sit-and-reach flexibility, plasma creatine kinase (CK), lactate dehydrogenase (LDH), and myoglobin (Mb) concentrations were quantified immediately before and after and 45 minutes, 24 and 48 hours after repeated-sprint running protocols. Although muscle damage was indicated by increases in CK, LDH, and Mb (p ≤ 0.05) in both groups, there was no significant effect of condition (TMa vs. TMd) on any of the measured performance or physiological variables (p > 0.05). The present study indicated that the removal of deceleration from repeated-sprint running on a nonmotorized treadmill has no effect on metabolism or performance during or after repeated-sprint running or markers of muscle damage.

  19. Functional quality of MR-compatible automatic biopsy guns compared with conventional ferromagnetic biopsy systems. An in vitro study

    International Nuclear Information System (INIS)

    Langen, H.J.; Landwehr, P.

    2001-01-01

    Comparative evaluation of specimens obtained with different MR-compatible biopsy systems and a conventional ferromagnetic system. Methods: Biopsies of a pig liver were performed post-mortem with three different MR-compatible (Somatex; E-Z-EM; Daum) and one conventional biopsy system (Somatex), five with each device. The specimens were measured and the histopathological quality was graded on a scale from 0 (no tissue) to 9 (best). The tip of the needle was examined with an electron microscope before and after biopsy to demonstrate abrasion. Results: The histopathological score between the first and fifth specimen taken with one biopsy device showed no significant difference. The conventional system yielded significantly better results in nearly all categories (p 2 ) were significantly smaller than those from the conventional system (9.98 mm 2 ). The needle tip abrasion of the different biopsy systems determined by electron microscopy showed no substantial difference. (orig.) [de

  20. Repeated nicotine exposure enhances reward-related learning in the rat.

    Science.gov (United States)

    Olausson, Peter; Jentsch, J David; Taylor, Jane R

    2003-07-01

    Repeated exposure to addictive drugs causes neuroadaptive changes in cortico-limbic-striatal circuits that may underlie alterations in incentive-motivational processes and reward-related learning. Such drug-induced alterations may be relevant to drug addiction because enhanced incentive motivation and increased control over behavior by drug-associated stimuli may contribute to aspects of compulsive drug-seeking and drug-taking behaviors. This study investigated the consequences of repeated nicotine treatment on the acquisition and performance of Pavlovian discriminative approach behavior, a measure of reward-related learning, in male rats. Water-restricted rats were trained to associate a compound conditioned stimulus (tone+light) with the availability of water (the unconditioned stimulus) in 15 consecutive daily sessions. In separate experiments, rats were repeatedly treated with nicotine (0.35 mg/kg, s.c.) either (1) prior to the onset of training, (2) after each daily training session was completed (ie postsession injections), or (3) received nicotine both before the onset of training as well as after each daily training session. In this study, all nicotine treatment schedules increased Pavlovian discriminative approach behavior and, thus, prior repeated exposure to nicotine, repeated postsession nicotine injections, or both, facilitated reward-related learning.

  1. Messengers of the universe: Session IV Summary

    International Nuclear Information System (INIS)

    Bernardini, Elisa; Serpico, Pasquale Dario

    2013-01-01

    Being stable, light and neutral weakly interacting particles, neutrinos are ideal messengers of the deep universe and a channel of choice in particular to explore the very high energy Galactic and Extragalactic sky, playing a synergic role most notably with gamma-ray observations. Neutrino astronomy—long after the SN1987A detection in the MeV range—is mature enough for decisive tests of astrophysical paradigms. Its current status constitutes one of the two big pillars of the “Messengers of the universe” session of the Neutrino Oscillation Workshop 2012. Neutrinos may also play a role in some cosmological contexts, such as the early universe and the dark matter problem. We review both aspects in this session summary report

  2. Buffered Communication Analysis in Distributed Multiparty Sessions

    Science.gov (United States)

    Deniélou, Pierre-Malo; Yoshida, Nobuko

    Many communication-centred systems today rely on asynchronous messaging among distributed peers to make efficient use of parallel execution and resource access. With such asynchrony, the communication buffers can happen to grow inconsiderately over time. This paper proposes a static verification methodology based on multiparty session types which can efficiently compute the upper bounds on buffer sizes. Our analysis relies on a uniform causality audit of the entire collaboration pattern - an examination that is not always possible from each end-point type. We extend this method to design algorithms that allocate communication channels in order to optimise the memory requirements of session executions. From these analyses, we propose two refinements methods which respect buffer bounds: a global protocol refinement that automatically inserts confirmation messages to guarantee stipulated buffer sizes and a local protocol refinement to optimise asynchronous messaging without buffer overflow. Finally our work is applied to overcome a buffer overflow problem of the multi-buffering algorithm.

  3. Parameterized Concurrent Multi-Party Session Types

    Directory of Open Access Journals (Sweden)

    Minas Charalambides

    2012-08-01

    Full Text Available Session types have been proposed as a means of statically verifying implementations of communication protocols. Although prior work has been successful in verifying some classes of protocols, it does not cope well with parameterized, multi-actor scenarios with inherent asynchrony. For example, the sliding window protocol is inexpressible in previously proposed session type systems. This paper describes System-A, a new typing language which overcomes many of the expressiveness limitations of prior work. System-A explicitly supports asynchrony and parallelism, as well as multiple forms of parameterization. We define System-A and show how it can be used for the static verification of a large class of asynchronous communication protocols.

  4. Electron and muon physics sessions: Summary

    International Nuclear Information System (INIS)

    Montgomery, H.E.

    1988-06-01

    The electromagnetic interaction needs no introduction as a probe of the structure of systems on many scales. The continued use of this technique dominated the sessions on Electron and Muon Physics at the Samoset Meeting. The experimental results continue to stimulate large numbers of theorists and the results on polarized deep inelastic muon scattering and their various interpretations permeated beyond these sessions. The breadth of physics attacked with electrons and muons makes a summary such as this rather peculiar. As one of my nuclear physics friends (I think) commented after my summary, ''it was interesting to see Nuclear Physics from a long distance with the telescope inverted.'' The comment may well be applied to this written version of the summary talk. 21 refs

  5. Coordination in continuously repeated games

    NARCIS (Netherlands)

    Weeren, A.J.T.M.; Schumacher, J.M.; Engwerda, J.C.

    1995-01-01

    In this paper we propose a model to describe the effectiveness of coordination in a continuously repeated two-player game. We study how the choice of a decision rule by a coordinator affects the strategic behavior of the players, resulting in more or less cooperation. Our model requires the analysis

  6. Repeated checking causes memory distrust

    NARCIS (Netherlands)

    van den Hout, M.; Kindt, M.

    2003-01-01

    This paper attempts to explain why in obsessive-compulsive disorder (OCD) checkers distrust in memory persists despite extensive checking. It is argued that: (1) repeated checking increases familiarity with the issues checked; (2) increased familiarity promotes conceptual processing which inhibits

  7. Psychological impact of serial prostate-specific antigen tests in Japanese men waiting for prostate biopsy.

    Science.gov (United States)

    Kobayashi, Minoru; Nukui, Akinori; Kamai, Takao

    2017-02-01

    It is common to repeat prostate-specific antigen (PSA) measurements for men with intermediate PSA elevation before prostate biopsy. In this scenario, men with persistently elevated PSA values may have considerable psychological distress. We attempted to determine whether elevated PSA values have psychological effects on these men in association with the timing of measurement, PSA kinetics, and biopsy results. In order to investigate the initial and late effects of PSA tests on psychological distress during serial measurements, two groups of men with screen-positive results (PSA ≥3 ng/ml) were studied-205 men whose first questionnaires regarding anxiety and depression were taken at initial screening (group A), and 103 men whose questionnaires were taken at repeated measurement for prior PSA elevation (group B). The level of distress was generally low. There were no significant differences in distress between the two groups, suggesting a constant psychological effect by elevated PSA values over a long period of time. The distress of men in group A increased significantly as PSA levels rose and decreased when they fell to normal range. On the other hand, the distress of men in group B did not change regardless of PSA kinetics, indicating that their psychological condition seemed susceptible to subtle PSA change only in the initial phase of measurements. Unexpectedly, men with benign results showed insignificant but higher distress after prostate biopsy. Although a small fraction of men have psychological distress caused by changes in PSA levels, the benefits, risks (psychological and physical), and limitations of PSA tests must be adequately explained to the patients before entering the screening program.

  8. Improved detection and biopsy of solid liver lesions using pulse-inversion ultrasound scanning and contrast agent infusion

    DEFF Research Database (Denmark)

    Skjoldbye, B.; Pedersen, Morten Høgholm; Struckmann, J.

    2002-01-01

    The purpose of this study was to assess the ability of pulse-inversion ultrasound (US) scanning (PIUS), combined with an IV contrast agent, to detect malignant liver lesions and its impact on patient management (resectability). Additionally, to determine the feasibility of US-guided biopsy of new...... PIUS-findings at the same session. A total of 30 patients with known or clinically suspected cancer underwent conventional B-mode scanning and PIUS with IV-administered contrast agent. The number of liver metastases in the right and the left liver lobe, respectively, was recorded. All patients...... findings were performed in 17 of 18 patients. All biopsies of additional findings confirmed malignancy. PIUS with an IV contrast agent increased the ability to detect liver metastases compared to conventional US scanning. The technique had a high impact on patient management. The results showed that PIUS...

  9. Security analysis of session initiation protocol

    OpenAIRE

    Dobson, Lucas E.

    2010-01-01

    Approved for public release; distribution is unlimited The goal of this thesis is to investigate the security of the Session Initiation Protocol (SIP). This was accomplished by researching previously discovered protocol and implementation vulnerabilities, evaluating the current state of security tools and using those tools to discover new vulnerabilities in SIP software. The CVSS v2 system was used to score protocol and implementation vulnerabilities to give them a meaning that was us...

  10. Robust and Scalable DTLS Session Establishment

    OpenAIRE

    Tiloca, Marco; Gehrmann, Christian; Seitz, Ludwig

    2016-01-01

    The Datagram Transport Layer Security (DTLS) protocol is highly vulnerable to a form of denial-of-service attack (DoS), aimed at establishing a high number of invalid, half-open, secure sessions. Moreover, even when the efficient pre-shared key provisioning mode is considered, the key storage on the server side scales poorly with the number of clients. SICS Swedish ICT has designed a security architecture that efficiently addresses both issues without breaking the current standard.

  11. MRI-Guided Percutaneous Biopsy of Mediastinal Masses Using a Large Bore Magnet: Technical Feasibility

    Energy Technology Data Exchange (ETDEWEB)

    Garnon, J., E-mail: juliengarnon@gmail.com [Nouvel Hôpital Civil, Department of Interventional Radiology (France); Ramamurthy, N., E-mail: nitin-ramamurthy@hotmail.com [Norfolk and Norwich University Hospital, Department of Radiology (United Kingdom); Caudrelier J, J., E-mail: caudjean@yahoo.fr [Nouvel Hôpital Civil, Department of Interventional Radiology (France); Erceg, G., E-mail: erceggorislav@yahoo.com; Breton, E., E-mail: ebreton@unistra.fr [ICube, University of Strasbourg, CNRS (France); Tsoumakidou, G., E-mail: gtsoumakidou@yahoo.com; Rao, P., E-mail: pramodrao@me.com; Gangi, A., E-mail: gangi@unistra.fr [Nouvel Hôpital Civil, Department of Interventional Radiology (France)

    2016-05-15

    ObjectiveTo evaluate the diagnostic accuracy and safety of magnetic resonance imaging (MRI)-guided percutaneous biopsy of mediastinal masses performed using a wide-bore high-field scanner.Materials and MethodsThis is a retrospective study of 16 consecutive patients (8 male, 8 female; mean age 74 years) who underwent MRI-guided core needle biopsy of a mediastinal mass between February 2010 and January 2014. Size and location of lesion, approach taken, time for needle placement, overall duration of procedure, and post-procedural complications were evaluated. Technical success rates and correlation with surgical pathology (where available) were assessed.ResultsTarget lesions were located in the anterior (n = 13), middle (n = 2), and posterior mediastinum (n = 1), respectively. Mean size was 7.2 cm (range 3.6–11 cm). Average time for needle placement was 9.4 min (range 3–18 min); average duration of entire procedure was 42 min (range 27–62 min). 2–5 core samples were obtained from each lesion (mean 2.6). Technical success rate was 100 %, with specimens successfully obtained in all 16 patients. There were no immediate complications. Histopathology revealed malignancy in 12 cases (4 of which were surgically confirmed), benign lesions in 3 cases (1 of which was false negative following surgical resection), and one inconclusive specimen (treated as inaccurate since repeat CT-guided biopsy demonstrated thymic hyperplasia). Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy in our study were 92.3, 100, 100, 66.7, and 87.5 %, respectively.ConclusionMRI-guided mediastinal biopsy is a safe procedure with high diagnostic accuracy, which may offer a non-ionizing alternative to CT guidance.

  12. Safety Training: scheduled sessions in April

    CERN Multimedia

    DGS Unit

    2011-01-01

    The following training courses are scheduled in April. You can find the full Safety Training programme on the Safety Training online catalogue. If you are interested in attending any of the below courses, please talk to your supervisor, then apply electronically via EDH from the course description pages, by clicking on SIGN-UP. Registration for all courses is always open – sessions for the less-requested courses are organized on a demand-basis only. Depending on the demand, a session will be organised later in the year. Biocell Training 26-APR-11 (08.30 – 10.00) in French 26-APR-11 (10.30 – 12.00) in French Conduite de plates-formes élévatrices mobiles de personnel (PEMP) 28-APR-11 to 29-APR-11 (08.00 – 17.30) in French* Sécurité chimique – Introduction 29-APR-11 (09.00 – 11.30) in French (*) session in French with the possibility of receiving the documentation in English   By Isabelle Cusato (H...

  13. Bone healing response in cyclically loaded implants: Comparing zero, one, and two loading sessions per day.

    Science.gov (United States)

    de Barros E Lima Bueno, Renan; Dias, Ana Paula; Ponce, Katia J; Wazen, Rima; Brunski, John B; Nanci, Antonio

    2018-05-31

    When bone implants are loaded, they are inevitably subjected to displacement relative to bone. Such micromotion generates stress/strain states at the interface that can cause beneficial or detrimental sequels. The objective of this study is to better understand the mechanobiology of bone healing at the tissue-implant interface during repeated loading. Machined screw shaped Ti implants were placed in rat tibiae in a hole slightly bigger than the implant diameter. Implants were held stable by a specially-designed bone plate that permits controlled loading. Three loading regimens were applied, (a) zero loading, (b) one daily loading session of 60 cycles with an axial force of 1.5 N/cycle for 7 days, and (c) two such daily sessions with the same axial force also for 7 days. Finite element analysis was used to characterize the mechanobiological conditions produced by the loading sessions. After 7 days, the implants with surrounding interfacial tissue were harvested and processed for histological, histomorphometric and DNA microarray analyses. Histomorphometric analyses revealed that the group subjected to repeated loading sessions exhibited a significant decrease in bone-implant contact and increase in bone-implant distance, as compared to unloaded implants and those subjected to only one loading session. Gene expression profiles differed during osseointegration between all groups mainly with respect to inflammatory and unidentified gene categories. The results indicate that increasing the daily cyclic loading of implants induces deleterious changes in the bone healing response, most likely due to the accumulation of tissue damage and associated inflammatory reaction at the bone-implant interface. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  14. Response variability of different anodal transcranial direct current stimulation intensities across multiple sessions.

    Science.gov (United States)

    Ammann, Claudia; Lindquist, Martin A; Celnik, Pablo A

    It is well known that transcranial direct current stimulation (tDCS) is capable of modulating corticomotor excitability. However, a source of growing concern has been the observed inter- and intra-individual variability of tDCS-responses. Recent studies have assessed whether individuals respond in a predictable manner across repeated sessions of anodal tDCS (atDCS). The findings of these investigations have been inconsistent, and their methods have some limitations (i.e. lack of sham condition or testing only one tDCS intensity). To study inter- and intra-individual variability of atDCS effects at two different intensities on primary motor cortex (M1) excitability. Twelve subjects participated in a crossover study testing 7-min atDCS over M1 in three separate conditions (2 mA, 1 mA, sham) each repeated three times separated by 48 h. Motor evoked potentials were recorded before and after stimulation (up to 30min). Time of testing was maintained consistent within participants. To estimate the reliability of tDCS effects across sessions, we calculated the Intra-class Correlation Coefficient (ICC). AtDCS at 2 mA, but not 1 mA, significantly increased cortical excitability at the group level in all sessions. The overall ICC revealed fair to high reliability of tDCS effects for multiple sessions. Given that the distribution of responses showed important variability in the sham condition, we established a Sham Variability-Based Threshold to classify responses and to track individual changes across sessions. Using this threshold an intra-individual consistent response pattern was then observed only for the 2 mA condition. 2 mA anodal tDCS results in consistent intra- and inter-individual increases of M1 excitability. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. [Prostate cancer diagnostic by saturation randomized biopsy versus rigid targeted biopsy].

    Science.gov (United States)

    Defontaines, J; Salomon, L; Champy, C; Cholley, I; Chiaradia, M; de la Taille, A

    2017-12-01

    Optimal diagram teaming up randomized biopsy (BR) to targeted biopsy (BC) is still missing for the diagnostic of prostate cancer (CP). This study compares diagram of 6, 12 or 18 BR with or without BC rigid. Between January 2014 and May 2016, 120 patients had prostate biopsy BR and BC. Each patient had 18 BR and BC. Results compared sextant (6 BR), standard (12 BR) and saturation (18 BR) protocol with or without the adding of BC for the detection of CP. Rectal examination was normal, mean PSA at 8.99ng/mL and mean volume at 54cm 3 . It was first round for 48% of patients. Forty-four cancers were found by the group 18 BR+BC (control). The detection rate was respectively, for 6, 12 and 18 BR of 61%, 82% and 91%. The add of BC increased this detection of +27% for 6 BR+BC, +13% for 12 BR+BC and +9% for 18 BR+BC. BC found 70% of all CP. Nine percent of CP were missed by BR only. Significant CP (Gleason≥7) diagnostic was the same for 12 BR+BC and 18 BR+BC. The add of BC to BR increase the detection of CP by 10%. Twelve BR+BC is the optimal diagram for the diagnostic of CP finding 95% of CP and 97% of significant CP. 4. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  16. Role of Ultrasound Guided Biopsy of Thoracic Lesions | Elameen ...

    African Journals Online (AJOL)

    Objective: This prospective study is to evaluate and enhance the role of ultrasound in biopsy guidance of thoracic lesions. Methods: 55 patients were subjected for fine needle aspiration (FNA) and/or core needle biopsy (CNB) from peripheral chest lesions in Ribat University Hospital during the period from April 2011 and ...

  17. CT guided percutaneous needle biopsy of the chest: initial experience

    African Journals Online (AJOL)

    The objective of this article is to report our first experience of CT guided percutaneous thoracic biopsy and to demonstrate the accuracy and safety of this procedure. This was a retrospective study of 28 CT-Guided Percutaneous Needle Biopsies of the Chest performed on 24 patients between November 2014 and April 2015.

  18. CT‑guided percutaneous transthoracic lung biopsy: First experience ...

    African Journals Online (AJOL)

    Percutaneous lung biopsy had been described in the nineteenth century by Leyden, but image- guided needle chest biopsy only gained widespread acceptance in the 1970s. Currently, tissue sampling of a thoracic lesion is indicated when the diagnosis cannot be obtained by the non-invasive techniques and cytological ...

  19. A review of transrectal ultrasound guided prostate biopsies: Is there ...

    African Journals Online (AJOL)

    Objective: We compared our institution's initial experience with transrectal ultrasound-guided (TRUS) prostate biopsies in a single arm prospective study to a historical cohort of finger guided (FG) biopsies. The primary outcome measure was prostate cancer detection. We documented our findings on TRUS including the ...

  20. [Closed needle-biopsy in the diagnosis of neoplasms].

    Science.gov (United States)

    Sforza, M; Perelli Ercolini, M; Beani, G

    1979-04-01

    The AA. demonstrate with this communication the validity of the needle biopsie for the diagnosis of neoplasms. They had used it for the breast, thyroid, flg and some other superficial tumefactions. In the mass-screening for the feminine neoplasms the clinical examination and the needle biopsy are very good method for a careful diagnosis.

  1. Prostatic biopsy after irradiation therapy for prostatic cancer

    International Nuclear Information System (INIS)

    Scardino, P.T.; Wheeler, T.M.

    1985-01-01

    To determine the prognostic significance of a routine needle biopsy of the prostate performed six to thirty-six months after the completion of definitive radiotherapy, biopsy results were analyzed in 146 patients who had no evidence of disease at the time of biopsy and who received no other therapy before proved recurrence of the tumor. Patients were followed up a mean of 3.9 years after radioactive gold seed implantation and external beam irradiation. The total dose was 8,000 rad. Among 146 patients, 56 (38%) had one or more positive biopsy results within this time interval. The positive biopsy rate correlated with the clinical stage ranging from 17 per cent in Stage B1N to 59 per cent in Stage C1. The risk of developing local recurrence or distant metastases at any given time after irradiation therapy was markedly greater in those patients with a positive biopsy result (p less than 0.0005). Prostatic biopsy is an accurate means of measuring the success of radiotherapy. A positive postirradiation biopsy result carries grave prognostic implications for the patient and indicates that the treatment has failed

  2. Morphological pattern of endometrial biopsies in southwestern Nigeria

    African Journals Online (AJOL)

    Background: Endometrium remains the most sensitive indicator of ovarian function and endometrial biopsy is one of the diagnostic procedures in endometrial pathology. The current study was carried out to examine the morphological pattern of endometrial biopsies in Ibadan, South-western Nigeria and compare the results ...

  3. Sentinel lymph node biopsy in breast cancer and melanoma

    NARCIS (Netherlands)

    Doting, Meintje Hylkje Edwina

    2007-01-01

    Summary and conclusions In the introduction, a short overview of the development of the sentinel lymph node biopsy concept is presented. In addition to melanoma and breast cancer, the usefulness of sentinel lymph node biopsy as a surgical assessment method for squamous cell carcinoma of penis and

  4. Short Communication Evaluation of an underwater biopsy probe for ...

    African Journals Online (AJOL)

    This study evaluated the use of a novel underwater biopsy probe designed to collect muscle and dermal tissue samples from large (170–220 cm total length), free-swimming bull sharks Carcharhinus leucas. The biopsy probe tissue retention rate was 87% after 23 trials, and the mean size of retained tissue was 310 mg (SD ...

  5. Diagnosis of prostate cancer with needle biopsy: Should all cases ...

    African Journals Online (AJOL)

    Background: The triad of digital rectal examination (DRE), serum prostate specific antigen, and transrectal ultrasound‑guided prostate biopsy is used in the detection of prostate cancer (PCa). It is recommended that all cases of PCa should be diagnosed with needle biopsy before treatment. The exclusion criteria for those ...

  6. Sensitivity of Computed Tomography‑guided Transthoracic Biopsies ...

    African Journals Online (AJOL)

    2018-03-05

    Mar 5, 2018 ... Introduction: The indications for open biopsies for intrathoracic lesions have become almost negligible. This development was made possible by less invasive maneuvers such as computed tomography‑guided (CT‑guided) biopsy, thoracoscopy or video‑assisted thoracoscopy, and bronchoscopy.

  7. Sensitivity of Computed Tomography‑guided Transthoracic Biopsies ...

    African Journals Online (AJOL)

    Introduction: The indications for open biopsies for intrathoracic lesions have become almost negligible. This development was made possible by less invasive maneuvers such as computed tomography‑guided (CT‑guided) biopsy, thoracoscopy or video‑assisted thoracoscopy, and bronchoscopy. CT‑guided percutaneous ...

  8. Magnetic resonance imaging guided biopsy of musculoskeletal lesions

    Directory of Open Access Journals (Sweden)

    Hung-Ta H. Wu

    2012-04-01

    Conclusion: Biopsy under MRI guidance is especially valuable for the localization of bone marrow lesions, viable tumors (after chemotherapy or radiation, and lesions that cannot be visualized using CT. It is both accurate and safe, is a good alternative biopsy method, and may be a good adjunctive technique for the localization of bone lesions for radiofrequency ablation or other interventional procedures.

  9. A novel technique for diaphragm biopsies in human patients.

    Science.gov (United States)

    Noullet, Séverine; Romero, Norma; Menegaux, Fabrice; Chapart, Maud; Demoule, Alexandre; Morelot-Panzini, Capucine; Similowski, Thomas; Gonzalez-Bermejo, Jésus

    2015-06-15

    The diaphragm is difficult to biopsy because of its anatomic location. We describe a new laparoscopic diaphragm biopsy technique. Fifty one patients with amyotrophic lateral sclerosis gave their consent to diaphragm biopsy in the context of an implanted phrenic nerve stimulation protocol (NCT01583088). The biopsy was taken from the costal diaphragm, after opening the parietal peritoneum with scissors, and by grasping the diaphragmatic muscle over the rib with toothed laparoscopy forceps. The first four electrocoagulation biopsies were unsuitable for morphologic examination. The following 47 biopsies were therefore performed without electrocoagulation. The mean size of the biopsy fragments obtained after preparation was 3 ± 1 × 2 ± 1 × 1 ± 1 mm (maximum: 4 × 3 × 2 mm). A diaphragmatic injury occurred during the section in three cases requiring immediate suture without causing pneumothorax. A small pleural effusion was observed on the postoperative chest x-ray in one patient with a spontaneously favorable outcome. Numerous stains were able to be performed on the fragments obtained. Diaphragm biopsy can be safely performed by laparoscopy and yields tissue suitable for our future histologic evaluation. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Biopsying southern right whales : Their reactions and effects on reproduction

    NARCIS (Netherlands)

    Best, PB; Reeb, D; Rew, MB; Palsboll, PJ; Schaeff, C; Brandao, A

    Collecting skin biopsies from large whales for genetic analysis is often subject to national permit, and in the case of cow-calf pairs, it may be prohibited. We present results of 906 biopsy attempts on southern fight whales (Eubalaena australis) in South African waters between 1995 and 1997,

  11. Duodenal versus jejunal biopsies in suspected celiac disease

    NARCIS (Netherlands)

    Thijs, WJ; van Baarlen, J; Kleibeuker, JH; Kolkman, JJ

    2004-01-01

    Background and Study Aims: In the past, small-bowel biopsies for diagnosis of celiac disease were taken from the jejunum with a suction capsule, but nowadays most physicians take endoscopic biopsies from the distal duodenum. To validate that practice we compared the diagnostic yield of endoscopic

  12. Testicular Biopsy In The Evaluation Of Male Infertility In Maiduguri ...

    African Journals Online (AJOL)

    Objective: To evaluate testicular biopsy in the management of male infertility in the university of Maiduguri Teaching Hospital. Method: This study reviewed retrospectively testicular biopsy in the infertile males managed at University of Maiduguri Teaching Hospital between january 1991 and December 2000.

  13. Diffuse reflectance imaging: a tool for guided biopsy

    Science.gov (United States)

    Jayanthi, Jayaraj L.; Subhash, Narayanan; Manju, Stephen; Nisha, Unni G.; Beena, Valappil T.

    2012-01-01

    Accurate diagnosis of premalignant or malignant oral lesions depends on the quality of the biopsy, adequate clinical information and correct interpretation of the biopsy results. The major clinical challenge is to precisely locate the biopsy site in a clinically suspicious lesion. Dips due to oxygenated hemoglobin absorption have been noticed at 545 and 575 nm in the diffusely reflected white light spectra of oral mucosa and the intensity ratio R545/R575 has been found suited for early detection of oral pre-cancers. A multi-spectral diffuse reflectance (DR) imaging system has been developed consisting of an electron multiplying charge coupled device (EMCCD) camera and a liquid crystal tunable filter for guiding the clinician to an optimal biopsy site. Towards this DR images were recorded from 27 patients with potentially malignant lesions on their tongue (dorsal, lateral and ventral sides) and from 44 healthy controls at 545 and 575 nm with the DR imaging system. False colored ratio image R545/R575 of the lesion provides a visual discerning capability that helps in locating the most malignant site for biopsy. Histopathological report of guided biopsy showed that out of the 27 patients 16 were cancers, 9 pre-cancers and 2 lichen planus. In this clinical trial DR imaging has correctly guided 25 biopsy sites, yielding a sensitivity of 93% and a specificity of 98%, thereby establishing the potential of DR imaging as a tool for guided biopsy.

  14. Comparison between Doppler Ultrasound and Biopsy Findings in ...

    African Journals Online (AJOL)

    Methods: We retrospectively studied a random sample of 188 kidney transplanted patients who had Doppler-ultrasound examination followed within two weeks by transplant biopsy. We evaluated the specificity and sensitivity of Doppler ultrasound in diagnosing rejection at different RI thresholds, using the reported biopsy ...

  15. Effect of squatting on sprinting performance and repeated exposure to complex training in male rugby players.

    Science.gov (United States)

    Comyns, Thomas M; Harrison, Andrew J; Hennessy, Liam K

    2010-03-01

    This study was undertaken to examine the effect of a heavy weight training exercise on sprinting performance and on the effect of repeated exposure to a complex training protocol. Eleven male rugby union players (age 20.9 +/- 3.1 years) participated in the study, which involved 5 separate testing sessions. Back squat 3 repetition maximum (3RM) was established in session 1. Sessions 2-5 were identical and involved the subjects completing a 30-m sprint before and after a 3RM back squat protocol. Four minutes of rest was given between the back squatting and the posttest 30-m sprint. All sprint trials were measured with a laser measurement device (LAVEG, Jenoptik, Jena, Germany). Sprint time and instantaneous, average, and maximum velocity were the dependent variables. The criterion for significance was set at an alpha level of p > or = 0.05. No significant improvement was evident for any of the testing sessions (p > or = 0.05). In session 1, there was a significant increase in 30-m time and a significant reduction in average 30-m velocity and maximum velocity (p benefits in sprinting may not have been realized because of intra and intersubject variations in sprint technique. The session x phase interaction revealed a significant improvement in the pre to posttest changes in instantaneous velocity at 20 m (p = 0.035) and 30 m (p = 0.036) from session 1 to session 4. This indicates that the rugby players may be able to learn to apply the potentiation effects of complex training. From a practical perspective, players may need repeated exposure to this training modality to gain benefit from it, and this should be reflected in program planning.

  16. Ultrastructural examination of skin biopsies may assist in diagnosing mitochondrial cytopathy when muscle biopsies yield negative results.

    Science.gov (United States)

    McAfee, John L; Warren, Christine B; Prayson, Richard A

    2017-08-01

    Ultrastructural evaluation of skin biopsies has been utilized for diagnosis of mitochondrial disease. This study investigates how frequently skin biopsies reveal mitochondrial abnormalities, correlates skin and muscle biopsy findings, and describes clinical diagnoses rendered following the evaluation. A retrospective review of surgical pathology reports from 1990 to 2015 identified skin biopsies examined by electron microscopy for suspected metabolic disease. A total of 630 biopsies were included from 615 patients. Of these patients, 178 also underwent a muscle biopsy. Of the 630 skin biopsies, 75 (12%) showed ultrastructural abnormalities and 34 (5%) specifically showed mitochondrial abnormalities including increased size (n=27), reduced or abnormal cristae (n=23), dense matrices (n=20), and increased number (n=8). Additional findings included lysosomal abnormalities (n=13), lipid accumulation (n=2) or glycogen accumulation (n=1). Of the 34 patients with mitochondrial abnormalities on skin biopsy, 20 also had muscle biopsies performed and nine showed abnormalities suggestive of a mitochondrial disorder including absent cytochrome oxidase staining (n=2), increased subsarcolemmal NADH, SDH, or cytochrome oxidase staining (n=1), or ultrastructural findings including large mitochondrial size (n=5), abnormal mitochondrial structure (n=5), and increased mitochondrial number (n=4). The most common presenting symptoms were intellectual disability (n=13), seizures (n=12), encephalopathy (n=9), and gastrointestinal disturbances (n=9). At last known follow-up, 12 patients had a definitive diagnosis of a mitochondrial disorder. One patient each had Complex I deficiency, Complex III deficiency, Charcot-Marie-Tooth disease, pyruvate dehydrogenase deficiency, and Phelan-McDermid syndrome. Our results suggest that skin biopsy sometimes yields diagnostic clues suggestive of a mitochondrial cytopathy in cases with a negative muscle biopsy. Copyright © 2017 Elsevier Inc. All rights

  17. Painful percutaneous transthoracic needle biopsy of Schwannoma: a case report

    International Nuclear Information System (INIS)

    Kim, Sung Hoon; Chun, Kyung Ah; Kim, Young Joo; Park, Seog Hee; Shin, Kyung Sub; Lee, Eun Jung

    1995-01-01

    Percutaneous aspiration needle biopsy of the intrathoracic disease is a safe, easy, and accurate diagnostic method. It usually causes mild pain or discomfort during the procedure. We had a patient who complained of severe sharp pain, well localized at the biopsy site of the target mass during CT-guided transthoracic aspiration biopsy. It was pathologically confirmed as an intrathoracic schwannoma after special staining. To our knowledge, there has been no published report of such a painful percutaneous needle biopsy in a patient with schwannoma in Korea. Two cases were reported in other radiologic journals. The severe sharp pain developed during the transthoracic aspiration needle biopsy is a reliable sign of neurogenic tumor, therefore the participating radiologist should recommend specific immumochemical stain for neurogenic tumor to pathologist

  18. Aspiration biopsy of testis: another method for histologic examination

    International Nuclear Information System (INIS)

    Nseyo, U.O.; Englander, L.S.; Huben, R.P.; Pontes, J.E.

    1984-01-01

    The most important method for evaluating the pathogenesis of male infertility is open testicular biopsy. Herein the authors describe a method of aspiration biopsy of testis for histologic examination. Sexually mature dogs and rats treated with chemotherapeutic agents and ionizing radiation were followed with periodic testicular aspiration biopsy during and after treatment. The histologic findings from the aspiration biopsy compare with the results of routine histologic examination in assessing spermatogenetic activity and delineating pathologic changes. The puncture in the experimental animals was performed under general anesthesia. In human patients testicular biopsy could be done under local anesthesia in an outpatient clinic. The procedure would be less painful, minimally invasive, and more cost-effective

  19. Morphologic Features Suggestive of Endometriosis in Nondiagnostic Peritoneal Biopsies.

    Science.gov (United States)

    Harrison, Beth T; Mittal, Khush

    2015-11-01

    Endometriosis is a common disorder that causes significant morbidity from dysmenorrhea, pelvic pain, and subfertility. Establishment of a definitive diagnosis has important therapeutic implications; however, only approximately 50% of biopsies of laparoscopically suspicious areas provide a diagnosis of endometriosis. Histologic criteria for diagnosis require the presence of endometrial glands or endometrial-type stroma. We hypothesize that other frequently present, but nondiagnostic, histologic features of endometriosis suggest its presence in patients with nondiagnostic peritoneal biopsies. We performed a retrospective clinicopathologic study of morphologic and immunohistochemical features that may improve the histologic diagnosis of endometriosis on laparoscopic peritoneal biopsies. We compared diagnostic (n=88) and nondiagnostic (n=54) peritoneal biopsies from pathologically confirmed endometriosis cases with negative peritoneal biopsies (n=84) from early-stage gynecologic cancer cases. Statistical analysis utilized the Fisher exact test. Multiple morphologic features were significantly increased in nondiagnostic biopsies from patients with endometriosis in comparison with those from negative controls, including foamy macrophages (P=0.0001) and submesothelial stromal clusters (SSCs) (P=0.0008). SSCs ranged from subtle aggregates of spindle cells to nodules of whorled spindle cells with small vessels and extravasated red blood cells resembling stromal endometriosis. Immunohistochemical studies confirmed that ER and CD10-positive SSCs were present in a greater proportion of both nondiagnostic and diagnostic peritoneal biopsies and at a greater number of lesions per biopsy. The overall histologic detection rate of peritoneal biopsies for endometriosis was 62.0%, and inclusion of SSCs with or without foamy macrophages in the diagnostic criteria appreciably increased this rate to between 72.5% and 76.8%. We describe SSCs, which appear to be an early or less developed

  20. CT-guided core-needle biopsy in omental pathology

    International Nuclear Information System (INIS)

    Pombo, F.; Rodriguez, E.; Martin, R.; Lago, M.

    1997-01-01

    Purpose: To assess the accuracy and clinical usefulness of CT-guided core-needle biopsy in the diagnosis of omental pathology. Material and Methods: We retrospectively reviewed the results of CT-guided percutaneous core biopsies in 25 patients with focal (n=2) or diffuse (n=23) omental pathology. These results were compared to the final diagnoses as determined by laparotomy (n=15), laparoscopic biopsy (n=3), endoscopic biopsy (n=1), or by the results of percutaneous biopsy and clinical-radiological and bacteriological modalities (n=6). The final diagnoses showed 4 patients with isolated omental pathology and 21 with widespread peritoneal involvement. The CT-guided biopsies were performed with 1.0=1.8-mm Surecut core-needles. Results: In 16 patients, the final diagnosis was metastatic adenocarcinoma - with the primary tumor sites in the ovary (n=3), stomach (n=1), appendix (n=2), and unknown (n=10). In the remaining 9 patients, the final diagnosis was hepatocellular carcinoma, lymphoma, and mesothelioma in 1 patient each; tuberculosis in 5; and actinomycosis in 1. Sufficient histological (n=16) or cytological (n=8) material was obtained by CT biopsy in 24/25 (96%) cases; the specimen was insufficient for diagnosis in 1 case. In differentiating benign from malignant disease, CT-guided biopsy showed a sensitivity, specificity and accuracy of respectively 89.5%, 100% and 92%. It gave a specific diagnosis in 78.9% (15/19) of patients with malignant conditions and in 50% (3/6) of patients with benign disorders. There were no biopsy-related complications. Conclusion: CT-guided percutaneous core-needle biopsy of the omentum is a safe, useful and highly accurate procedure for diagnosing malignant omental pathology. (orig.)

  1. Online learning in repeated auctions

    OpenAIRE

    Weed, Jonathan; Perchet, Vianney; Rigollet, Philippe

    2015-01-01

    Motivated by online advertising auctions, we consider repeated Vickrey auctions where goods of unknown value are sold sequentially and bidders only learn (potentially noisy) information about a good's value once it is purchased. We adopt an online learning approach with bandit feedback to model this problem and derive bidding strategies for two models: stochastic and adversarial. In the stochastic model, the observed values of the goods are random variables centered around the true value of t...

  2. Optical Systems of Biopsy: The Invisible Eye

    Directory of Open Access Journals (Sweden)

    Kriti Bagri-Manjrekar

    2012-01-01

    Full Text Available The exploration of new methods and techniques for the diagnosis of malignant tumours has always attracted the attention of scientists. The development of adjunct tools to facilitate the non invasive screening of high risk lesions in real time has the potential to significantly improve our ability to reduce the dismal morbidity and mortality of oral cancer. Despite easy accessibility of the oral cavity to examination, there is no satisfactory method to adequately screen and detect precancers non-invasively. The current method of oral cancer diagnosis clinically relies heavily on visual examination of the oral cavity. However, discerning potentially malignant and early malignant lesions from common benign inflammatory conditions can be difficult at times. There is a need for an objective method that could provide real- time results and be routinely applied to a large population. Though science is yet to present such a perfect technique, Optical Biopsy Systems developed using knowledge of light and tissue interaction, can provide a plausible option.

  3. Hybrid tracers for sentinel node biopsy

    International Nuclear Information System (INIS)

    Van Den Berg, N. S.; Kleinjan, G. I.; Valdés-Olmos, R. A.; Buckle, T.; Van Leeuwen, F. I.; Klop, W. M.; Horenblas, S.; Van Der Poel, H. G.

    2014-01-01

    Conventional sentinel node (SN) mapping is performed by injection of a radiocolloid followed by lymphoscintigraphy to identify the number and location of the primary tumor draining lymph node(s), the so-called SN(s). Over the last decade research has focused on the introduction of new imaging agents that can further aid (surgical) SN identification. Different tracers for SN mapping, with varying sizes and isotopes have been reported, most of which have proven their value in a clinical setting. A major challenge lies in transferring this diagnostic information obtained at the nuclear medicine department to the operating theatre thereby providing the surgeon with (image) guidance. Conventionally, an intraoperative injection of vital blue dye or a fluorescence dye is given to allow intraoperative optical SN identification. However, for some indications, the radiotracer-based approach remains crucial. More recently, hybrid tracers, that contain both a radioactive and fluorescent label, were introduced to allow for direct integration of pre- and intraoperative guidance technologies. Their potential is especially high when they are used in combination with new surgical imaging modalities and navigation tools. Next to a description of the known tracers for SN mapping, this review discusses the application of hybrid tracers during SN biopsy and how the introduction of these new techniques can further aid in translation of nuclear medicine information into the operating theatre.

  4. A repeating fast radio burst.

    Science.gov (United States)

    Spitler, L G; Scholz, P; Hessels, J W T; Bogdanov, S; Brazier, A; Camilo, F; Chatterjee, S; Cordes, J M; Crawford, F; Deneva, J; Ferdman, R D; Freire, P C C; Kaspi, V M; Lazarus, P; Lynch, R; Madsen, E C; McLaughlin, M A; Patel, C; Ransom, S M; Seymour, A; Stairs, I H; Stappers, B W; van Leeuwen, J; Zhu, W W

    2016-03-10

    Fast radio bursts are millisecond-duration astronomical radio pulses of unknown physical origin that appear to come from extragalactic distances. Previous follow-up observations have failed to find additional bursts at the same dispersion measure (that is, the integrated column density of free electrons between source and telescope) and sky position as the original detections. The apparent non-repeating nature of these bursts has led to the suggestion that they originate in cataclysmic events. Here we report observations of ten additional bursts from the direction of the fast radio burst FRB 121102. These bursts have dispersion measures and sky positions consistent with the original burst. This unambiguously identifies FRB 121102 as repeating and demonstrates that its source survives the energetic events that cause the bursts. Additionally, the bursts from FRB 121102 show a wide range of spectral shapes that appear to be predominantly intrinsic to the source and which vary on timescales of minutes or less. Although there may be multiple physical origins for the population of fast radio bursts, these repeat bursts with high dispersion measure and variable spectra specifically seen from the direction of FRB 121102 support an origin in a young, highly magnetized, extragalactic neutron star.

  5. Percutaneous biopsy of malignant hepatic tumor in patients with bleeding tendency : usefulness of gelfoam plugging up the biopsy track

    International Nuclear Information System (INIS)

    Yoon, Hye Ran; Kwak, Byung Kook; Choi, Chi Hoon; Park, Yong Ok; Yang, Keun Myeong; Seo, Ja Young; Lee, Shin Hyung; Lee, Chang Joon; Shim, Hyung Jin

    1998-01-01

    To plug the biopsy site in eight patients with coagulopathy who had undergone percutaneous liver biopsy. To this end, gelfoam cartridge was used as a sealant. Materials and Methods: Using an 18G Tru-Cut-type disposable automated biopsy gun(Soo Ho Medi-tech, Seoul, Korea) and under US guidance, eight patients underwent percutaneous liver biopsy. After the gun had fired, the biopsy specimen in the inner stylet was retrieved while the outer cannula was held in place ; the cannula was then used to plug the biopsy tracks with gelfoam, using two or three cartridges. If bleeding occurred, this was controlled by the use of more gelfoam cartridges. Results:Diagnostic target tissue was obtained in seven of the eight patients(87.5%). Hepatocellular carcinoma was diagnosed in five cases and metastatic cancer in two. Profuse bleeding was observed in one patient(12.5%) and resolved by gelfoam plugging. Conclusion: We believe that in patients with coagulopathy who are required to undergo liver biopsy plugging the liver biopsy track with gelfoam cartridge is a simple, safe and useful method

  6. Stereotactic large-core needle breast biopsy: analysis of pain and discomfort related to the biopsy procedure

    International Nuclear Information System (INIS)

    Hemmer, Judith M.; Heesewijk, Hans P.M. van; Kelder, Johannes C.

    2008-01-01

    The purpose of this study was to determine the significance of variables such as duration of the procedure, type of breast tissue, number of passes, depth of the biopsies, underlying pathology, the operator performing the procedure, and their effect on women's perception of pain and discomfort during stereotactic large-core needle breast biopsy. One hundred and fifty consecutive patients with a non-palpable suspicious mammographic lesions were included. Between three and nine 14-gauge breast passes were taken using a prone stereotactic table. Following the biopsy procedure, patients were asked to complete a questionnaire. There was no discomfort in lying on the prone table. There is no relation between type of breast lesion and pain, underlying pathology and pain and performing operator and pain. The type of breast tissue is correlated with pain experienced from biopsy (P = 0.0001). We found out that patients with dense breast tissue complain of more pain from biopsy than patients with more involution of breast tissue. The depth of the biopsy correlates with pain from biopsy (P = 0.0028). Deep lesions are more painful than superficial ones. There is a correlation between the number of passes and pain in the neck (P = 0.0188) and shoulder (P = 0.0366). The duration of the procedure is correlated with pain experienced in the neck (P = 0.0116) but not with pain experienced from biopsy. (orig.)

  7. PSA and androgen-related gene (AR, CYP17, and CYP19) polymorphisms and the risk of adenocarcinoma at prostate biopsy

    DEFF Research Database (Denmark)

    dos Santos, Rodrigo Mattos; de Jesus, Carlos Márcio Nóbrega; Trindade Filho, José Carlos Souza

    2008-01-01

    The aim of the present study was to examine the impact of polymorphisms in prostate-specific antigen (PSA) and androgen-related genes (AR, CYP17, and CYP19) on prostate cancer (PCa) risk in selected high-risk patients who underwent prostate biopsy. Blood samples and prostate tissues were obtained......=0.0110) genotypes. Genetic instability at the AR locus leading to somatic mosaicism was detected in one PCa patient by comparing the length of AR CAG repeats in matched peripheral blood and prostate biopsy cores. Taken together, these findings suggest that the PSA genotype should be a clinically relevant biomarker...

  8. Studying different tasks of implicit learning across multiple test sessions conducted on the web

    Directory of Open Access Journals (Sweden)

    Werner eSævland

    2016-06-01

    Full Text Available Implicit learning is usually studied through individual performance on a single task, with the most common tasks being Serial Reaction Time task (SRT; Nissen and Bullemer, 1987, Dynamic System Control task (DSC; (Berry and Broadbent, 1984 and artificial Grammar Learning task (AGL; (Reber, 1967. Few attempts have been made to compare performance across different implicit learning tasks within the same experiment. The current experiment was designed study the relationship between performance on the DSC Sugar factory task (Berry and Broadbent, 1984 and the Alternating Serial Reaction Time task (ASRT; (Howard and Howard, 1997. We also addressed another limitation to traditional implicit learning experiments, namely that implicit learning is usually studied in laboratory settings over a restricted time span lasting for less than an hour (Berry and Broadbent, 1984; Nissen and Bullemer, 1987; Reber, 1967. In everyday situations, implicit learning is assumed to involve a gradual accumulation of knowledge across several learning episodes over a larger time span (Norman and Price, 2012. One way to increase the ecological validity of implicit learning experiments could be to present the learning material repeatedly across shorter experimental sessions (Howard and Howard, 1997; Cleeremans and McClelland, 1991. This can most easily be done by using a web-based setup that participants can access from home. We therefore created an online web-based system for measuring implicit learning that could be administered in either single or multiple sessions. Participants (n = 66 were assigned to either a single-session or a multi-session condition. Learning and the degree of conscious awareness of the learned regularities was compared across condition (single vs. multiple sessions and tasks (DSC vs. ASRT. Results showed that learning on the two tasks was not related. However, participants in the multiple sessions condition did show greater improvements in reaction

  9. Moderator report on workshop session 3

    International Nuclear Information System (INIS)

    Isaacs, T.

    2004-01-01

    While much in Stakeholder confidence work is focused on the periods of project conceptualization, siting, and development, eventually a successful waste programme will result in a set of facilities with visual, aesthetic, and other physical impacts on the host community. This most interesting and interactive session explored both the artistic and aesthetic aspects of the waste management process and the relationship among the stakeholders, particularly the affected local communities and those who might help develop both the products and processes associated with implementation. Two insightful presentations were made, followed by a lively panel discussion and interactions with the broader FSC participants. (author)

  10. Parallel Monitors for Self-adaptive Sessions

    Directory of Open Access Journals (Sweden)

    Mario Coppo

    2016-06-01

    Full Text Available The paper presents a data-driven model of self-adaptivity for multiparty sessions. System choreography is prescribed by a global type. Participants are incarnated by processes associated with monitors, which control their behaviour. Each participant can access and modify a set of global data, which are able to trigger adaptations in the presence of critical changes of values. The use of the parallel composition for building global types, monitors and processes enables a significant degree of flexibility: an adaptation step can dynamically reconfigure a set of participants only, without altering the remaining participants, even if the two groups communicate.

  11. Summary of Session 4 "Beam Energy"

    CERN Document Server

    Siemko, A

    2011-01-01

    In this session, the possible scenarios for the beam energy in the LHC 2011 run were discussed. The benefits for the physics reach for physics operations at s larger than 7 TeV were reviewed. The main goal was, however, to establish the necessary information for a sound risk analysis by assessing the probability of thermal runaway and evaluating the consequences of a hypothetical incident. A new technique to improve the knowledge of joint resistances of the cooper busbars and therefore the reliability of the risk analysis has also been discussed.

  12. Summary of the electron accelerators session

    International Nuclear Information System (INIS)

    Prescott, C.Y.

    1988-10-01

    Since the last High Energy Physics Symposium, there has been considerable progress in the field of polarized electron accelerators. Projects well into construction include the SLC, HERA, and LEP. The status of polarized beams for these projects is discussed in this session. Semiclassical and quantum mechanical calculations of polarizing and depolarizing effects are discussed, for both linear colliders and for storage rings. Substantial progress is continuing in the understanding of depolarizing mechanisms for circular machines. Modelling of these machines is underway. Activities with polarized electron beams at Novosibirsk are described. 8 refs

  13. Breast cancer: determining the genetic profile from ultrasound-guided percutaneous biopsy specimens obtained during the diagnostic workups.

    Science.gov (United States)

    López Ruiz, J A; Zabalza Estévez, I; Mieza Arana, J A

    2016-01-01

    To evaluate the possibility of determining the genetic profile of primary malignant tumors of the breast from specimens obtained by ultrasound-guided percutaneous biopsies during the diagnostic imaging workup. This is a retrospective study in 13 consecutive patients diagnosed with invasive breast cancer by B-mode ultrasound-guided 12 G core needle biopsy. After clinical indication, the pathologist decided whether the paraffin block specimens seemed suitable (on the basis of tumor size, validity of the sample, and percentage of tumor cells) before sending them for genetic analysis with the MammaPrint® platform. The size of the tumors on ultrasound ranged from 0.6cm to 5cm. In 11 patients the preserved specimen was considered valid and suitable for use in determining the genetic profile. In 1 patient (with a 1cm tumor) the pathologist decided that it was necessary to repeat the core biopsy to obtain additional samples. In 1 patient (with a 5cm tumor) the specimen was not considered valid by the genetic laboratory. The percentage of tumor cells in the samples ranged from 60% to 70%. In 11/13 cases (84.62%) it was possible to do the genetic analysis on the previously diagnosed samples. In most cases, regardless of tumor size, it is possible to obtain the genetic profile from tissue specimens obtained with ultrasound-guided 12 G core biopsy preserved in paraffin blocks. Copyright © 2015 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  14. 3D non-rigid surface-based MR-TRUS registration for image-guided prostate biopsy

    Science.gov (United States)

    Sun, Yue; Qiu, Wu; Romagnoli, Cesare; Fenster, Aaron

    2014-03-01

    Two dimensional (2D) transrectal ultrasound (TRUS) guided prostate biopsy is the standard approach for definitive diagnosis of prostate cancer (PCa). However, due to the lack of image contrast of prostate tumors needed to clearly visualize early-stage PCa, prostate biopsy often results in false negatives, requiring repeat biopsies. Magnetic Resonance Imaging (MRI) has been considered to be a promising imaging modality for noninvasive identification of PCa, since it can provide a high sensitivity and specificity for the detection of early stage PCa. Our main objective is to develop and validate a registration method of 3D MR-TRUS images, allowing generation of volumetric 3D maps of targets identified in 3D MR images to be biopsied using 3D TRUS images. Our registration method first makes use of an initial rigid registration of 3D MR images to 3D TRUS images using 6 manually placed approximately corresponding landmarks in each image. Following the manual initialization, two prostate surfaces are segmented from 3D MR and TRUS images and then non-rigidly registered using a thin-plate spline (TPS) algorithm. The registration accuracy was evaluated using 4 patient images by measuring target registration error (TRE) of manually identified corresponding intrinsic fiducials (calcifications and/or cysts) in the prostates. Experimental results show that the proposed method yielded an overall mean TRE of 2.05 mm, which is favorably comparable to a clinical requirement for an error of less than 2.5 mm.

  15. Comparison of Battery-Powered and Manual Bone Biopsy Systems for Core Needle Biopsy of Sclerotic Bone Lesions.

    Science.gov (United States)

    Cohen, Micah G; McMahon, Colm J; Kung, Justin W; Wu, Jim S

    2016-05-01

    The purpose of this study was to compare manual and battery-powered bone biopsy systems for diagnostic yield and procedural factors during core needle biopsy of sclerotic bone lesions. A total of 155 consecutive CT-guided core needle biopsies of sclerotic bone lesions were performed at one institution from January 2006 to November 2014. Before March 2012, lesions were biopsied with manual bone drill systems. After March 2012, most biopsies were performed with a battery-powered system and either noncoaxial or coaxial biopsy needles. Diagnostic yield, crush artifact, CT procedure time, procedure radiation dose, conscious sedation dose, and complications were compared between the manual and battery-powered core needle biopsy systems by Fisher exact test and t test. One-way ANOVA was used for subgroup analysis of the two battery-powered systems for procedure time and radiation dose. The diagnostic yield for all sclerotic lesions was 60.0% (93/155) and was significantly higher with the battery-powered system (73.0% [27/37]) than with the manual systems (55.9% [66/118]) (p = 0.047). There was no significant difference between the two systems in terms of crush artifact, procedure time, radiation dose, conscious sedation administered, or complications. In subgroup analysis, the coaxial battery-powered biopsies had shorter procedure times (p = 0.01) and lower radiation doses (p = 0.002) than the coaxial manual systems, but the noncoaxial battery-powered biopsies had longer average procedure times and higher radiation doses than the coaxial manual systems. In biopsy of sclerotic bone lesions, use of a battery-powered bone drill system improves diagnostic yield over use of a manual system.

  16. Innovative Software Algorithms and Tools parallel sessions summary

    International Nuclear Information System (INIS)

    Gaines, Irwin

    2001-01-01

    A variety of results were presented in the poster and 5 parallel sessions of the Innovative Software, Algorithms and Tools (ISAT) sessions. I will briefly summarize these presentations and attempt to identify some unifying trends

  17. 78 FR 53497 - Commercial Space Transportation Advisory Committee; Closed Session

    Science.gov (United States)

    2013-08-29

    ... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Commercial Space Transportation... Commercial Space Transportation Advisory Committee Special Closed Session. SUMMARY: Pursuant to Section 10(a...), notice is hereby given of a special closed session of the Commercial Space Transportation Advisory...

  18. Chapter II: Twenty Eighth General Assembly Business Sessions

    Science.gov (United States)

    Williams, Robert

    2015-08-01

    The President of the IAU, Prof. Robert Williams, welcomed the delegates and members to this first business session of the General Assembly. The President invited the General Secretary, Dr. Ian Corbett, to start the business session.

  19. Music Education and Music Therapy. Introduction to Plenary Session 3

    DEFF Research Database (Denmark)

    Bonde, Lars Ole

    2002-01-01

    Chairman's introduction to plenary session on the relationship between music therapy and music pedagogics......Chairman's introduction to plenary session on the relationship between music therapy and music pedagogics...

  20. Intra- and Intersession Repeatability of an Optical Quality and Intraocular Scattering Measurement System in Children.

    Directory of Open Access Journals (Sweden)

    Mi Tian

    Full Text Available To evaluate intra- and intersession repeatability of objective optical quality and intraocular scattering measurements with a double-pass system in children.Forty-two eyes of 42 children were included in the study. An optical quality analysis system (OQAS was used to measure optical quality parameters, including modulation transfer function cutoff frequency (MTFcutoff, Strehl ratio (SR, OQAS values (OV at 3 different contrasts and objective scatter index (OSI. Three measurement sessions with 10-min intervals were operated by the same technician, and in each session four consecutive measurements were obtained.Mean values for MTFcutoff, SR and OSI were 46.85 ± 7.45cpd, 0.27 ± 0.06 and 0.34 ± 0.22 respectively. 1 The intraclass correlation coefficients were ranged from 0.89 to 0.97 and coefficients of variation from 0.06 to 0.16 for all the parameters in the first session; the relative repeatability were 11.1% (MTFcutoff, 22.5% (SR, 10.9% (OV100%, 16.6% (OV2%, 22.4% (OV9% and 56.3% (OSI. Similar results were found in the second and third sessions. 2 Bland-Altman analysis showed that narrow 95% confidence intervals (compared between the first and second sessions ranged from -5.42 to 5.28 (MTFcutoff, -0.05 to 0.07 (SR, -0.18 to 0.18 (OV100%, -0.26 to 0.29 (OV20%, -0.33 to 0.39 (OV9% and -0.11 to 0.09 (OSI; the comparison between any two of the three sessions showed similar results.Measurements of optical quality and intraocular scattering in children by the double-pass system showed good intra- and intersession repeatability. Retinal image quality is high and intraocular scattering is low in children.

  1. Safety Training: scheduled sessions in March

    CERN Multimedia

    DGS Unit

    2011-01-01

    The following training courses are scheduled in March. You can find the full Safety Training programme on the Safety Training online catalogue. If you are interested in attending any of the below courses, please talk to your supervisor, then apply electronically via EDH from the course description pages, by clicking on SIGN-UP. Registration for all courses is always open – sessions for the less-requested courses are organized on a demand-basis only. Depending on the demand, a session will be organised later in the year. Biocell Training 08-MAR-11 (08.30 – 10.00) in English 08-MAR-11 (10.30 – 12.00) in French 15-MAR-11 (08.30 – 10.00) in French 15-MAR-11 (10.30 – 12.00) in French 17-MAR-11 (08.30 – 10.00) in English 17-MAR-11 (10.30 – 12.00) in English 22-MAR-11 (08.30 – 10.00) in French 22-MAR-11 (10.30 – 12.00) in French 24-MAR-11 (08.30 – 10.00) in French 24-MAR-11 (10.30 – 12.00) in French 29-MAR...

  2. Safety Training: scheduled sessions in May

    CERN Multimedia

    Isabelle Cusato (HSE Unit)

    2011-01-01

    The following training courses are scheduled in March. You can find the full Safety Training programme on the Safety Training online catalogue. If you are interested in attending any of the below courses, please talk to your supervisor, then apply electronically via EDH from the course description pages, by clicking on SIGN-UP. Registration for all courses is always open – sessions for the less-requested courses are organized on a demand-basis only. Depending on the demand, a session will be organised later in the year.   Biocell Training 10-MAY-11 (08.30 – 10.00) in French 10-MAY-11 (10.30 – 12.00) in French 12-MAY-11 (08.30 – 10.00) in English 12-MAY-11 (10.30 – 12.00) in English 19-MAY-11 (08.30 – 10.00) in French 19-MAY-11 (10.30 – 12.00) in French 24-MAY-11 (08.30 – 10.00) in English 24-MAY-11 (10.30 – 12.00) in English   Champs Magnétiques 13-MAY-11 (09.30 – 11.30) in French...

  3. Round table discussion during session 2

    International Nuclear Information System (INIS)

    Mays, C.

    2004-01-01

    The round table discussions of the second session of the FSC Belgium Workshop addressed the following questions: - Do local stakeholders have, internally or externally, all the expertise they need in order to address the issues raised by radioactive waste management projects? - Do institutional stakeholders have all the expertise they need to take local impacts into account? - What kinds of expert input are sought and attained by the different stakeholders? - Were any formal methods used to aid local partnerships perform technology assessments? Or other types of assessment? - How to maintain the knowledge and expertise achieved by the stakeholders? Discussion took place after the plenary presentations, at tables grouping Belgian stakeholders and FSC delegates. As in Session I, most of the round table discussion focussed specifically on the experience of the local partnerships. Many insights were shared about the nature and role of expertise in complex decision making. They are summarised below, on the basis of the feedback provided to the plenary by each round table. Some of these insights can be generalised to other contexts. All in all, a profile emerged of the local partnerships as a unique and effective tool to deal with knowledge issues in managing risk. (author)

  4. Aspen Global Change Institute Summer Science Sessions

    Energy Technology Data Exchange (ETDEWEB)

    Katzenberger, John; Kaye, Jack A

    2006-10-01

    The Aspen Global Change Institute (AGCI) successfully organized and convened six interdisciplinary meetings over the course of award NNG04GA21G. The topics of the meetings were consistent with a range of issues, goals and objectives as described within the NASA Earth Science Enterprise Strategic Plan and more broadly by the US Global Change Research Program/Our Changing Planet, the more recent Climate Change Program Strategic Plan and the NSF Pathways report. The meetings were chaired by two or more leaders from within the disciplinary focus of each session. 222 scholars for a total of 1097 participants-days were convened under the auspices of this award. The overall goal of each AGCI session is to further the understanding of Earth system science and global environmental change through interdisciplinary dialog. The format and structure of the meetings allows for presentation by each participant, in-depth discussion by the whole group, and smaller working group and synthesis activities. The size of the group is important in terms of the group dynamics and interaction, and the ability for each participant's work to be adequately presented and discussed within the duration of the meeting, while still allowing time for synthesis

  5. Digital imaging improves upright stereotactic core biopsy of mammographic microcalcifications

    International Nuclear Information System (INIS)

    Whitlock, J.P.L.; Evans, A.J.; Burrell, H.C.; Pinder, S.E.; Ellis, I.O.; Blamey, R.W.; Wilson, A.R.M.

    2000-01-01

    AIM: This comparative study was carried out to assess the effect of using digital images compared to conventional film-screen mammography on the accuracy of core biopsy of microcalcifications using upright stereotactic equipment. MATERIALS AND METHODS: The biopsy results from a consecutive series of 104 upright stereotactic 14-gauge core biopsies performed with conventional X-ray (Group A) were compared with 40 biopsies carried out using stereotaxis with digital imaging (Group B). In all cases specimen radiography was performed and analysed for the presence of calcifications. Pathological correlation was then carried out with needle and surgical histology. RESULTS: The use of digital add-on equipment increased the radiographic calcification retrieval rate from 55 to 85% (P < 0.005). The absolute sensitivity of core biopsy in pure ductal carcinoma in situ (DCIS) cases rose from 34 to 69% (P < 0.03), with the complete sensitivity increasing from 52 to 94% (P < 0.005). For DCIS with or without an invasive component the absolute sensitivity rose from 41 to 67% (P = 0.052), while the complete sensitivity was 59% before and 86% after the introduction of digital imaging (P < 0.04). CONCLUSION: Digital equipment improves the performance of upright stereotactic core biopsy of microcalcifications, giving a significantly increased success rate in accurately obtaining calcifications. This leads to an improvement in absolute and complete sensitivity of core biopsy when diagnosing DCIS. Whitlock, J.P.L. (2000)

  6. Mammotome HH biopsy - the future of minimal invasive breast surgery?

    International Nuclear Information System (INIS)

    Pietrzyk, G.; Nowicki, J.; Bojarski, B.; Kedzierski, B.; Wysocki, A.; Prudlak, E.

    2007-01-01

    Vacuum-assisted breast biopsy / Mammotome HH '' R '' Breast Biopsy System/ is the milestone in the diagnosis of breast lesions. This system has proven to be as diagnostically reliable as open surgery, but without scarring, deformations and hospitalizations associated with an open procedure. The aim of our study was to assess the role and possibilities of using this biopsy in treatment of benign breast lesions like fibroadenoma. From 2001 to 2004, about 1118 Mammotome biopsies were performed in our Department. Among 445 Mammotome biopsies performed under US control there were 211 cases of fibroadenomas. Follow-up was performed in 156 patients with this result at 6 and 12 months after biopsy. In our study we took into considerations the size, localizations as well as performers. In 2002 there were 70.8% patients with total lesion excision, 16.7% with residual lesion and 12.5% women with hematomas or scars. In 2003-2004 there were more women with total lesion excision (84.3%), fewer residual tumors and other lesions. In future, Mammotome breast biopsy can replace scalpel, and will become an alternative method to open surgical excision of fibroadenomas. It is important especially in the cases of young women to prevent cosmetic deformations and scars. (author)

  7. Sentinel lymph node biopsy in local recurrence of cutaneous melanoma

    International Nuclear Information System (INIS)

    Junqueira, G. Jr.; Bodanese, B.; Boff, M.F.; Espindola, M.B.; Haack, R.L.; Frigeri, C.D.L.

    2004-01-01

    Full text: Locally recurrent disease in patients with melanoma is usually defined as cutaneous or subcutaneous arising within 5 cm of the primary site after complete excision of the primary lesion. It may represent residual disease not excised with the primary tumor or the outgrowth of the satellite lesions, which are common with melanoma. Lymphatic mapping and sentinel lymph node (SLN) biopsy is highly accurate in staging nodal basins at risk of regional metastases in primary melanoma patients and identifies those who may benefit from earlier lymphadenectomy. Our purpose was to evaluate the efficacy of sentinel lymph node mapping and biopsy in local recurrence of cutaneous melanoma when the primary lesion was less than 1.0mm thick. Three patients with local recurrence of cutaneous melanoma underwent sentinel lymph node mapping and biopsy. All patients underwent preoperative lymphoscintigraphy to identify the lymphatic basin and the site of the sentinel node. All patients subsequently underwent intra-operative lymphatic mapping and selective lymph node biopsy with vital blue dye and hand-held gamma probe. Excised SLN were analysed by conventional histological staining (H and E) and immunohistochemical staining. In all patients the lymphatic mapping and sentinel lymph node biopsy was successful. The SLN biopsy was negative in two patients and positive in one who underwent therapeutic lymph node dissection. Our results indicate that the SLN mapping and biopsy is also possible in patients having local recurrence of cutaneous melanoma. Although long-term results are not available, early results are promising. (author)

  8. Superficial biopsy of the cervix: new technique

    Directory of Open Access Journals (Sweden)

    Ettore De Girolami

    2002-06-01

    Full Text Available Cytological examination of the cervix in all patients is considered a necessity. A new technique of superficial biopsy is described and advantages en. numeratedEl Autor presenta una nueva técnica para biopsia superficial, considerando la necesidad de hacer rutinariamente a todas las pacientes el examen citológico del cérvix. La muestra se toma con el extremo de un aplicador cubierto de gaza. Este dispositivo, humedecido previamente en una solución de etanol, metanol y éter etílico, se aplica inmediatamente al cérvix del útero y, dándole un movimiento como el de las manecillas del reloj, se toma la muestra con la que se hacen frotis por aposición que se colorean por el método de Giemsa. Esta técnica ofrece la ventaja de que el tejido en estudio se adhiere perfectamente a la gaza, la cual, con el movimiento de rotación, desprende las células del "os uteri", las que son fijadas al mismo tiempo. La preparación del dispositivo es sumamente sencilla. La prueba resulta de bajo costo como de breve y fácil realizaciónL' Autore prende in considerazione l'utilitá dell' esame citologico del collo dell'utero, fatto rutinariamente a tutte le pazienti. Si descrive una nuova tecnica di biopsia superficiale che oltfe ad offrire dei vantaggi é di poca spesa e si puó eseguire con facilitá ed in breve tempo

  9. Sentinel lymph node biopsy: clinical relevance

    International Nuclear Information System (INIS)

    Howman-Giles, R.

    2002-01-01

    Sentinel lymph node biopsy (SLNB) has become an important technique in the management of patients with intermediate level melanoma, clinical operable breast cancer and some other cancers. The technique relies on lymphatic mapping to define the lymph drainage from a primary tumour with the premise that the lymph nodes, which directly drain from that area, will reflect the tumour status of the remainder of the node field. Current techniques use lymphoscintigraphy where a radioactive labelled particle and / or blue dye are injected intradermally or intraparenchymally to map the lymph drainage, often in conjunction with a radioactive gamma probe at surgery. In patients with melanoma the SLNB has improved the staging and prognostic information by more accurate determination of whether regional lymph nodes have metastatic spread. This has a major impact on patient management as those patients with negative nodes do not require regional lymph node dissection and have a significantly better prognosis. In our experience of over 3000 patients the combined sentinel node biopsy technique localised accurately 98% of sentinel lymph nodes. Lymphoscintigraphy in patients with melanoma to locate the sentinel lymph nodes involves the intradermal injection of a radiocolloid around the melanoma site or the excision biopsy site. Injections of 5 -10 MBq in 0.05-0.1ml/inj are used and typically 4 injections are usually required. Following tracer injection dynamic imaging is performed to follow the lymphatic collecting vessels until they reach the draining sentinel nodes. An image should be acquired as the vessels reach the node field so that the sentinel nodes directly receiving the channels can be identified and distinguished from any second tier nodes which may sometimes be seen. Delayed scans are performed 2 hours later at which time all regions which can possible drain the primary melanoma site are examined with 5-10 minute static images. The surface location of all sentinel nodes is

  10. Does Prebiopsy, Nonsterile Ultrasonography Gel Affect Biopsy-Site Asepsis?

    International Nuclear Information System (INIS)

    Gurel, Kamil; Karabay, Oguz; Gurel, Safiye; Hildebolt, Charles

    2008-01-01

    Purpose. The purpose of this study was to determine the extent to which the use of nonsterile gel, prior to antiseptic procedures in ultrasonography (US)-guided percutaneous biopsies, results in contamination of the biopsy site. Materials and Methods. Patients referred for US-guided percutaneous biopsies were included in this study. Transmission material used for US evaluation before biopsy-site antiseptic procedures were performed was either nonsterile gel or sterile saline. Patients were randomly assigned to two groups: nonsterile gel (n = 30) and sterile saline (n = 30). Before the transmission material was used and after antiseptic procedures were performed, microbial swabs of a 10-cm 2 -diameter area were obtained at the biopsy site. Swabs were also obtained from the gel, saline, and povidine-iodine. Inoculated specimen plates were incubated at 37 o C under aerobic conditions, and the numbers of colony-forming units recorded. Nominal logistic regression analysis was used to calculate the odds of postantisepsis bacterial growth (after antiseptic procedures were performed) based on group, gender, coincidental disease (diabetes, chronic renal failure, and malignancy), biopsy-site location (head and neck or breast and abdomen), and local factors (skin fold, skin tag, and hair). Results. The following odds ratios (adjusted for the other variables) and their 95% confidence intervals were calculated: (1) group (2.9 [0.8-11.1]; p = 0.10); (2) gender (1.2 [0.3-5.2]; p = 0.78); (3) coincidental disease (7.6 [0.9-166.7]; p = 0.09); (4) biopsy site location (6.2 [1.4-31.3]; p = 0.02); and (5) local factors (7.0 [1.6-36.0]; p = 0.01). No bacterial growth occurred with swabs obtained from gel, povidine-iodine, or saline. Conclusion. We conclude that nonsterile gel used prior to percutaneous biopsy does not affect biopsy-site asepsis

  11. Ultrasound-guided core needle biopsy for breast cancer

    International Nuclear Information System (INIS)

    Naqvi, S.Q.H.; Solangi, R.A.; Memon, M.; Solangi, R.A.

    2008-01-01

    To evaluate the efficacy of ultrasound-guided core needle biopsy (US-CNB) as a preoperative diagnostic modality for breast cancer. Females with solid and/or intermediate breast lesions visualized on ultrasonography. Apart from clinical work-up, all the above mentioned patients underwent ultrasound-guided core needle biopsy and excisional biopsy of their breast lesions. The histopathological diagnosis on ultrasound-guided core needle biopsy was then compared with the findings of the excisional biopsy. Out of the total 93 cases, 47(50.5%) had benign lesions on ultrasound; US-CNB showed 24 as fibroadenomata, four with chronic non-specific mastitis, five chronic suppurative mastitis, one tuberculosis, four fat necrosis, two lactational adenoma and seven cases with benign ductal hyperplasia without atypia. Nine (9.7%) cases showed suspicious abnormality on ultrasound; US-CNB revealed five cases with atypical ductal hyperplasia, one ductal carcinoma in situ and three invasive ductal carcinoma. Thirty seven (39.8%) cases were highly suggestive of malignancy on ultrasound; US-CNB showed 34 as invasive ductal carcinoma, two invasive lobular and one medullary carcinoma. Excisional biopsy confirmed the diagnosis of ultrasound-guided core needle biopsy in all cases except four; one case of chronic suppurative mastitis was diagnosed as that of tuberculosis and three cases of atypial ductal hyperplasia as invasive ductal carcinoma. Hence there was no false positive case, but four (4.3%) false negative cases. The sensitivity of the US-CNB was thus 100% and specificity 91.1%. Ultrasound guided core needle biopsy is a satisfactory procedure for the histopathological diagnosis of breast lesions. Any unsatisfactory, suspicious or atypical change on US-CNB should be followed by an open biopsy. (author)

  12. Determining Criteria to Predict Repeatability of Performance in Older Adults: Using Coefficients of Variation for Strength and Functional Measures.

    Science.gov (United States)

    Raj, Isaac Selva; Bird, Stephen R; Westfold, Ben A; Shield, Anthony J

    2017-01-01

    Reliable measures of muscle strength and functional capacity in older adults are essential. The aim of this study was to determine whether coefficients of variation (CVs) of individuals obtained at the first session can infer repeatability of performance in a subsequent session. Forty-eight healthy older adults (mean age 68.6 ± 6.1 years; age range 60-80 years) completed two assessment sessions, and on each occasion undertook: dynamometry for isometric and isokinetic quadriceps strength, 6 meter fast walk (6MFWT), timed up and go (TUG), stair climb and descent, and vertical jump. Significant linear relationships were observed between CVs in session 1 and the percentage difference between sessions 1 and 2 for torque at 60, 120, 240 and 360°/s, 6MFWT, TUG, stair climb, and stair descent. The results of this study could be used to establish criteria for determining an acceptably reliable performance in strength and functional tests.

  13. Improving repeatability by improving quality

    Energy Technology Data Exchange (ETDEWEB)

    Ronen, Shuki; Ackers, Mark; Schlumberger, Geco-Prakla; Brink, Mundy

    1998-12-31

    Time lapse (4-D) seismic is a promising tool for reservoir characterization and monitoring. The method is apparently simple: to acquire data repeatedly over the same reservoir, process and interpret the data sets, then changes between the data sets indicate changes in the reservoir. A problem with time lapse seismic data is that reservoirs are a relatively small part of the earth and important reservoir changes may cause very small differences to the time lapse data. The challenge is to acquire and process economical time lapse data such that reservoir changes can be detected above the noise of varying acquisition and environment. 7 refs., 9 figs.

  14. Telomerase Repeated Amplification Protocol (TRAP).

    Science.gov (United States)

    Mender, Ilgen; Shay, Jerry W

    2015-11-20

    Telomeres are found at the end of eukaryotic linear chromosomes, and proteins that bind to telomeres protect DNA from being recognized as double-strand breaks thus preventing end-to-end fusions (Griffith et al. , 1999). However, due to the end replication problem and other factors such as oxidative damage, the limited life span of cultured cells (Hayflick limit) results in progressive shortening of these protective structures (Hayflick and Moorhead, 1961; Olovnikov, 1973). The ribonucleoprotein enzyme complex telomerase-consisting of a protein catalytic component hTERT and a functional RNA component hTR or hTERC - counteracts telomere shortening by adding telomeric repeats to the end of chromosomes in ~90% of primary human tumors and in some transiently proliferating stem-like cells (Shay and Wright, 1996; Shay and Wright, 2001). This results in continuous proliferation of cells which is a hallmark of cancer. Therefore, telomere biology has a central role in aging, cancer progression/metastasis as well as targeted cancer therapies. There are commonly used methods in telomere biology such as Telomere Restriction Fragment (TRF) (Mender and Shay, 2015b), Telomere Repeat Amplification Protocol (TRAP) and Telomere dysfunction Induced Foci (TIF) analysis (Mender and Shay, 2015a). In this detailed protocol we describe Telomere Repeat Amplification Protocol (TRAP). The TRAP assay is a popular method to determine telomerase activity in mammalian cells and tissue samples (Kim et al. , 1994). The TRAP assay includes three steps: extension, amplification, and detection of telomerase products. In the extension step, telomeric repeats are added to the telomerase substrate (which is actually a non telomeric oligonucleotide, TS) by telomerase. In the amplification step, the extension products are amplified by the polymerase chain reaction (PCR) using specific primers (TS upstream primer and ACX downstream primer) and in the detection step, the presence or absence of telomerase is

  15. Coordinated hybrid automatic repeat request

    KAUST Repository

    Makki, Behrooz

    2014-11-01

    We develop a coordinated hybrid automatic repeat request (HARQ) approach. With the proposed scheme, if a user message is correctly decoded in the first HARQ rounds, its spectrum is allocated to other users, to improve the network outage probability and the users\\' fairness. The results, which are obtained for single- and multiple-antenna setups, demonstrate the efficiency of the proposed approach in different conditions. For instance, with a maximum of M retransmissions and single transmit/receive antennas, the diversity gain of a user increases from M to (J+1)(M-1)+1 where J is the number of users helping that user.

  16. Percutaneous biopsy of the synovial membrane of large joints

    International Nuclear Information System (INIS)

    Begule, V.

    1989-01-01

    Using flouroscopy, the authors have developed new techniques of percutaneous synovial biopsy (PSB) of large joints of limbs (other than the knee). PSB was performed on outpatients under local anesthesia. They have performed 84 biopsies (hips: 57), shoulders: 10, elbows: six, wrists: five, ankles: six). The PSB technique was gradually improved. Main technical refinements were use of a Tru-Cut needle introduced through a Jamshidi trephine needle, placement of the cutting window parallel to the anterior aspect of the joint, and selection of an optimal approach and biopsy site. With these improvements, the success rate of attaining synovial membrane was raised from 49% to 81%. No complications were encountered

  17. Magnetic-resonance-guided biopsy of focal liver lesions

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Ethan A. [University of Michigan Health System, Section of Pediatric Radiology, C.S. Mott Children' s Hospital, Department of Radiology, Ann Arbor, MI (United States); Grove, Jason J. [University of Michigan Health System, Division of Interventional Radiology, C.S. Mott Children' s Hospital, Department of Radiology, Ann Arbor, MI (United States); Der Spek, Abraham F.L.V. [University of Michigan Health System, Department of Anesthesiology, C.S. Mott Children' s Hospital, Ann Arbor, MI (United States); Jarboe, Marcus D. [University of Michigan Health System, Division of Interventional Radiology, C.S. Mott Children' s Hospital, Department of Radiology, Ann Arbor, MI (United States); University of Michigan Health System, Section of Pediatric Surgery, C.S. Mott Children' s Hospital, Department of Surgery, Ann Arbor, MI (United States)

    2017-05-15

    Image-guided biopsy techniques are widely used in clinical practice. Commonly used methods employ either ultrasound (US) or computed tomography (CT) for image guidance. In certain patients, US or CT guidance may be suboptimal, or even impossible, because of artifacts, suboptimal lesion visualization, or both. We recently began performing magnetic resonance (MR)-guided biopsy of focal liver lesions in select pediatric patients with lesions that are not well visualized by US or CT. This report describes our experience performing MR-guided biopsy of focal liver lesions, with case examples to illustrate innovative techniques and novel aspects of these procedures. (orig.)

  18. Implementation of Upright Digital Breast Tomosynthesis-guided Stereotactic Biopsy.

    Science.gov (United States)

    Omofoye, Toma S; Martaindale, Sarah; Teichgraeber, Davis C; Parikh, Jay R

    2017-11-01

    With growing adoption of digital breast tomosynthesis, an increasing number of imaging abnormalities are being identified only by tomosynthesis. Upright digital breast tomosynthesis-guided stereotactic biopsy is a proven method for sampling these abnormalities as well as abnormalities traditionally evaluated using conventional stereotactic biopsy. In this article, we describe the technique of upright digital breast tomosynthesis-guided stereotactic biopsy and outline a systematic operational approach to implementation of this technique in clinical radiology practices. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  19. The Importance of Biopsy in the Era of Molecular Medicine.

    Science.gov (United States)

    Ziv, Etay; Durack, Jeremy C; Solomon, Stephen B

    Recent advances in the molecular characterization of cancers have triggered interest in developing a new taxonomy of disease in oncology with the goal of using the molecular profile of a patient's tumor to predict response to treatment. Image-guided needle biopsy is central to this "precision medicine" effort. In this review, we first discuss the current role of biopsy in relation to clinical examples of molecular medicine. We then outline important bottlenecks to the advancement of precision medicine and highlight the potential role of image-guided biopsy to address these challenges.

  20. Outbreak of persistent cutaneous abscesses due to Mycobacterium chelonae after mesotherapy sessions, Lima, Peru.

    Science.gov (United States)

    Munayco, César V; Grijalva, Carlos G; Culqui, Dante R; Bolarte, José L; Suárez-Ognio, Luis A; Quispe, Neyda; Calderon, Roger; Ascencios, Luis; Del Solar, Manuel; Salomón, Martín; Bravo, Francisco; Gotuzzo, Eduardo

    2008-02-01

    Outbreaks of rapidly growing mycobacteria have been occasionally described. The article reports an outbreak of cutaneous abscesses due to Mycobacterium chelonae following mesotherapy in Lima, Peru. From December 2004 through January 2005, 35 subjects who had participated in mesotherapy training sessions presented with persistent cutaneous abscesses. Thirteen (37%) of these suspected cases consented to undergo clinical examination. Skin punch-biopsies were collected from suspicious lesions and substances injected during mesotherapy were analyzed. Suspected cases were mainly young women and lesions included subcutaneous nodules, abscesses and ulcers. Mycobacterium chelonae was isolated from four patients and from a procaine vial. In conclusion, it is important to consider mesotherapy as a potential source of rapidly growing mycobacteria infections.