WorldWideScience

Sample records for repeat biopsy session

  1. Optimizing prostate biopsy for repeat transrectal prostate biopsies patients

    Institute of Scientific and Technical Information of China (English)

    Xiaojun Deng; Jianwei Cao; Feng Liu; Weifeng Wang; Jidong Hao; Jiansheng Wan; Hui Liu

    2014-01-01

    Objective:Diagnosis of patients with negative prostate biopsy and persistent suspicion of prostate cancer re-mains a serious problem. In this study, we investigated the application of optimizing prostate biopsy for patients who need repeat prostate biopsy. Methods:In this prospective, non-randomized phase-I clinical trial, the prostate cancer detection rate of initial detection scheme was compared with optimizing prostate biopsy scheme. The number of punctures of initial detection scheme was the same as that of optimizing prostate biopsy scheme. The puncture direction of optimizing prostate biopsy was a 45° angle to the sagittal plane from front, middle, and back. The two cores from each lateral lobe were horizontal y inwardly inclined 45°. Results:A total of 45 patients with initial negative biopsy for cancer were received the optimizing prostate biopsy scheme. The cancer detection rate was 17.8%(8/45), and prostate intraepithelial neoplasm (PIN) was 6.7%(3/45). The pa-tients receiving repeat transrectal prostate biopsies were pathological y diagnosed as lower Gleason grade prostate cancers. Conclusion:The cancer detection rate of repeat biopsy prostate cancer is lower than that of initial biopsy. Our study showed that the optimizing prostate biopsy is important to improve the detection rate of repeat transrectal prostate biopsies patients.

  2. Value of repeat biopsy in lupus nephritis flares

    Science.gov (United States)

    Greloni, G; Scolnik, M; Marin, J; Lancioni, E; Quiroz, C; Zacariaz, J; De la Iglesia Niveyro, P; Christiansen, S; Pierangelo, M A; Varela, C F; Rosa-Diez, G J; Catoggio, L J; Soriano, E R

    2014-01-01

    Objectives Renal flares are common in lupus nephritis (LN), and class switch is thought to be characteristic. There is no agreement on indications for performing a repeat renal biopsy. Our objective was to retrospectively review patients who had more than one renal biopsy performed on clinical indications, and analyse clinical, pathological and treatment changes after successive biopsies. Methods Forty-five patients with LN and one or more repeat renal biopsies were included, with a total of 116 biopsies. Results Of the 71 repeat biopsies, pathological transition occurred in 39 (54.9%). When having a previous biopsy with a proliferative lesion, class switch occurred in 55.6%, with 24.4% evolving into non-proliferative classes. When previous biopsy was class V, transition to other classes occurred in 58.3% and changes were all into proliferative classes. Conversion from one pure proliferative form to another (class III to class IV or vice versa) happened in 11.3% of the rebiopsies, with 62 rebiopsies (87.3%) leading to a change in the treatment regimen. Conclusions Histological transformations were common, and they occurred when the previous biopsy had non-proliferative lesions as well as when lesions were proliferative. Treatments were modified after repeat renal biopsy in the majority of patients. In this experience, kidney repeat biopsies were useful in guiding treatment of LN flares. PMID:25396056

  3. Reactivity to nicotine cues over repeated cue reactivity sessions

    Science.gov (United States)

    LaRowe, Steven D.; Saladin, Michael E.; Carpenter, Matthew J.; Upadhyaya, Himanshu P.

    2009-01-01

    The present study investigated whether reactivity to nicotine-related cues would attenuate across four experimental sessions held one week apart. Participants were nineteen non-treatment seeking, nicotine-dependent males. Cue reactivity sessions were performed in an outpatient research center using in vivo cues consisting of standardized smoking-related paraphernalia (e.g., cigarettes) and neutral comparison paraphernalia (e.g., pencils). Craving ratings were collected before and after both cue presentations while physiological measures (heart rate, skin conductance) were collected before and during the cue presentations. Although craving levels decreased across sessions, smoking-related cues consistently evoked significantly greater increases in craving relative to neutral cues over all four experimental sessions. Skin conductance was higher in response to smoking cues, though this effect was not as robust as that observed for craving. Results suggest that, under the described experimental parameters, craving can be reliably elicited over repeated cue reactivity sessions. PMID:17537583

  4. Reactivity to nicotine cues over repeated cue reactivity sessions.

    Science.gov (United States)

    LaRowe, Steven D; Saladin, Michael E; Carpenter, Matthew J; Upadhyaya, Himanshu P

    2007-12-01

    The present study investigated whether reactivity to nicotine-related cues would attenuate across four experimental sessions held 1 week apart. Participants were nineteen non-treatment seeking, nicotine-dependent males. Cue reactivity sessions were performed in an outpatient research center using in vivo cues consisting of standardized smoking-related paraphernalia (e.g., cigarettes) and neutral comparison paraphernalia (e.g., pencils). Craving ratings were collected before and after both cue presentations while physiological measures (heart rate, skin conductance) were collected before and during the cue presentations. Although craving levels decreased across sessions, smoking-related cues consistently evoked significantly greater increases in craving relative to neutral cues over all four experimental sessions. Skin conductance was higher in response to smoking cues, though this effect was not as robust as that observed for craving. Results suggest that, under the described experimental parameters, craving can be reliably elicited over repeated cue reactivity sessions.

  5. Repeated nondiagnostic result of thyroid fine-needle aspiration biopsy.

    Science.gov (United States)

    Ziemiańska, Klaudia; Kopczyński, Janusz; Kowalska, Aldona

    2016-01-01

    Fine-needle aspiration biopsy (FNAB) is the most accurate and cost-effective method to evaluate the risk of malignancy of thyroid nodules, but approximately 1-24% of FNABs generate a nondiagnostic result (ND-FNAB). The aim of this study was to determine the predictive factors of a repeated nondiagnostic result of FNAB. A total of 4018 FNABs performed in a territorial referral centre were analysed, of which 288 (7.17%) were nondiagnostic. Medical records were available for 245 biopsies performed in 228 patients. The retrospective analysis of factors that may influence a repeat ND-FNAB, including demographic, clinical and ultrasound characteristics, was performed. A repeat FNAB was performed in 159 nodules giving a diagnostic result in 79.2% of cases. The time between the biopsies ranged from 1 to 611 days (mean 154.4, median 119). The timing of a repeat FNAB did not significantly alter the diagnostic output (p = 0.29). In the univariate analysis, significant predictors of a repeat ND-FNAB were older patient age (p = 0.02), L-thyroxine supplementation (p = 0.05), and a history of (131)I therapy (p < 0.0001). In the multivariate analysis, only a history of (131)I therapy was a statistically significant risk factor for a repeat ND-FNAB (p = 0.002). Patients with a history of (131)I therapy and ND-FNAB should undergo periodic ultrasonographic assessment rather than a repeat biopsy. The interval between repeated FNABs recommended by guidelines does not affect the diagnostic output.

  6. Imaging and pathology findings after an initial negative MRI-US fusion-guided and 12-core extended sextant prostate biopsy session

    Science.gov (United States)

    Hong, Cheng William; Walton-Diaz, Annerleim; Rais-Bahrami, Soroush; Hoang, Anthony N.; Türkbey, Barış; Stamatakis, Lambros; Xu, Sheng; Amalou, Hayet; Minhaj Siddiqui, M.; Nix, Jeffrey W.; Vourganti, Srinivas; Merino, Maria J.; Choyke, Peter L.; Wood, Bradford J.; Pinto, Peter A.

    2014-01-01

    PURPOSE A magnetic resonance imaging-ultrasonography (MRI-US) fusion-guided prostate biopsy increases detection rates compared to an extended sextant biopsy. The imaging characteristics and pathology outcomes of subsequent biopsies in patients with initially negative MRI-US fusion biopsies are described in this study. MATERIALS AND METHODS We reviewed 855 biopsy sessions of 751 patients (June 2007 to March 2013). The fusion biopsy consisted of two cores per lesion identified on multiparametric MRI (mpMRI) and a 12-core extended sextant transrectal US (TRUS) biopsy. Inclusion criteria were at least two fusion biopsy sessions, with a negative first biopsy and mpMRI before each. RESULTS The detection rate on the initial fusion biopsy was 55.3%; 336 patients had negative findings. Forty-one patients had follow-up fusion biopsies, but only 34 of these were preceded by a repeat mpMRI. The median interval between biopsies was 15 months. Fourteen patients (41%) were positive for cancer on the repeat MRI-US fusion biopsy. Age, prostate-specific antigen (PSA), prostate volume, PSA density, digital rectal exam findings, lesion diameter, and changes on imaging were comparable between patients with negative and positive rebiopsies. Of the patients with positive rebiopsies, 79% had a positive TRUS biopsy before referral (P = 0.004). Ten patients had Gleason 3+3 disease, three had 3+4 disease, and one had 4+4 disease. CONCLUSION In patients with a negative MRI-US fusion prostate biopsy and indications for repeat biopsy, the detection rate of the follow-up sessions was lower than the initial detection rate. Of the prostate cancers subsequently found, 93% were low grade (≤3+4). In this low risk group of patients, increasing the follow-up time interval should be considered in the appropriate clinical setting. PMID:24509182

  7. A review of repeat prostate biopsies and the influence of technique on cancer detection: our experience.

    LENUS (Irish Health Repository)

    Quinlan, M R

    2012-02-01

    BACKGROUND: Follow-up of patients with an initial negative prostate biopsy, but surrounding whom a suspicion of prostate cancer persists, is difficult. In addition, debate exists as to the optimal technique for repeat prostate biopsy. AIMS: To assess the cancer detection rate on repeat prostate biopsy. METHODS: We reviewed patients who underwent prostate biopsy in our department in 2005 who had >or=1 previous biopsy within the preceding 5 years. Cancer detection rate on repeat biopsy and the influence of the number of biopsy cores were recorded. RESULTS: Cancer detection rate on repeat biopsy was 15.4%, with approximately 60% detected on the first repeat biopsy, but approximately 10% not confirmed until the fourth repeat biopsy. Gleason score was similar regardless of the time of diagnosis (6.1-6.5). Mean interval between first biopsy and cancer diagnosis (range 18-55 months) depended on the number of repeat procedures. There was an association between the number of biopsy cores and cancer detection. CONCLUSIONS: This study supports the practice of increasing the number of cores taken on initial and first repeat biopsy to maximise prostate cancer detection and reduce the overall number of biopsies needed.

  8. The diagnosis of cancer in thyroid fine needle aspiration biopsy. Surgery, repeat biopsy or specimen consultation?

    Directory of Open Access Journals (Sweden)

    Agata Stanek-Widera

    2016-05-01

    Full Text Available Fine needle aspiration biopsy (FNA is the only diagnostic method that allows a preoperative diagnosis of thyroid carcinoma. An unequivocal diagnosis of a malignant change is achievable only in cases in which all cytological criteria of carcinoma are met. The aim of the study was to evaluate the necessity of repeat thyroid FNA in patients with papillary thyroid carcinoma verified on consultative examination (CE. We analyzed cytology reports of thyroid FNA and CE that resulted in the diagnosis of papillary carcinoma. Evaluation of the correlation of the cytological diagnosis with the histopathology report was based on data obtained after the surgery. Between 2010 and 2015 in the Institute of Oncology (IO there were 184 cancers diagnosed on CE or in thyroid FNA performed primarily in IO. Additionally, 74 patients were subjected to repeat biopsy after confirmation of cancer in CE. Histopathological diagnosis of cancer was obtained in 62 (100% cases that were doubly confirmed with cytological examination. The remaining 12 patients were operated on outside the institute. From 110 FNA primarily performed in the IO, histopathological verification was achievable in 92 cases, from which 92 (100% provided a confirmation of cancer, and the remaining 18 patients were operated on outside the institute. High (100% specificity of cancer diagnosis in FNA established primarily and verified on CE (second independent assessment indicates that repeat FNA in order to confirm the diagnosis is unnecessary.

  9. Multiparametric MRI in men with clinical suspicion of prostate cancer undergoing repeat biopsy

    DEFF Research Database (Denmark)

    Boesen, Lars; Nørgaard, Nis; Løgager, Vibeke

    2017-01-01

    for detection of csPCa in men undergoing repeat biopsies. Material and Methods MpMRI was performed prior to re-biopsy in 289 prospectively enrolled patients. All underwent repeat TRUSbx followed by targeted biopsies (MRITB) of any mpMRI-identified lesion. MpMRI suspicion grade, PSA level, and density (PSAd...

  10. Anterior prostate biopsy at initial and repeat evaluation: is it useful to detect significant prostate cancer?

    Directory of Open Access Journals (Sweden)

    Pietro Pepe

    2015-10-01

    Full Text Available ABSTRACT Purpose: Detection rate for anterior prostate cancer (PCa in men who underwent initial and repeat biopsy has been prospectively evaluated. Materials and Methods: From January 2013 to March 2014, 400 patients all of Caucasian origin (median age 63.5 years underwent initial (285 cases and repeat (115 cases prostate biopsy; all the men had negative digital rectal examination and the indications to biopsy were: PSA values > 10 ng/mL, PSA between 4.1-10 or 2.6-4 ng/mL with free/total PSA≤25% and ≤20%, respectively. A median of 22 (initial biopsy and 31 cores (repeat biopsy were transperineally performed including 4 cores of the anterior zone (AZ and 4 cores of the AZ plus 2 cores of the transition zone (TZ, respectively. Results: Median PSA was 7.9 ng/mL; overall, a PCa was found in 180 (45% patients: in 135 (47.4% and 45 (36% of the men who underwent initial and repeat biopsy, respectively. An exclusive PCa of the anterior zone was found in the 8.9 (initial biopsy vs 13.3% (repeat biopsy of the men: a single microfocus of cancer was found in the 61.2% of the cases; moreover, in 7 out 18 AZ PCa the biopsy histology was predictive of significant cancer in 2 (28.5% and 5 (71.5% men who underwent initial and repeat biopsy, respectively. Conclusions: However AZ biopsies increased detection rate for PCa (10% of the cases, the majority of AZ PCa with histological findings predictive of clinically significant cancer were found at repeat biopsy (about 70% of the cases.

  11. Changes in pathological pattern and treatment regimens based on repeat renal biopsy in lupus nephritis

    Institute of Scientific and Technical Information of China (English)

    WANG Guo-bao; XU Zheng-jin; LIU Hong-fa; ZHOU Qiu-gen; ZHOU Zhan-mei; JIA Nan

    2012-01-01

    Background Relapses occur frequently in patients with lupus nephritis.Renal biopsy is the gold standard for assessing renal activity and hence guiding the treatment.Whether repeat renal biopsy is helpful during flares of lupus nephritis remains inconclusive.In the present study,we retrospectively reviewed the patients with lupus nephritis who had more than one renal biopsy with the hope to find the clinical value of repeat biopsy.Methods Patients who had a diagnosis of lupus nephritis and two or more renal biopsies were selected from the database of the patient pathology registration at this renal division.Renal biopsy was evaluated according to the International Society of Nephrology/Renal Pathology Society (ISN/RPS) classification of lupus nephritis.The pathological patterns and treatment regimens were analyzed after a repeat biopsy.Results We identified 44 systemic lupus erythematosus patients with serial renal biopsies.In total,there were 94 renal biopsies.Overall,the pathological transition occurred in 64% instances according to the ISN/RPS class.When the transition was analyzed according to proliferative,membranous or mix lesions,it showed different profile:35% in patients with proliferative lesion,23.5% patients with mix lesions,100% in patients with pure membranous lesion.The pathological transition could not be predicted by any clinical characteristics.After the repeat renal biopsy,34% of patients had a change in their treatment regimens.Conclusions The pathological conversion was very prevalent in patients with lupus nephritis.However,the transitions became less prevalent when they were analyzed according to pure membranous,proliferative,and mix lesion.Repeat biopsy might be helpful to avoid unnecessary increased immunosuppression therapy.

  12. Development and validation of risk score for predicting positive repeat prostate biopsy in patients with a previous negative biopsy in a UK population

    Directory of Open Access Journals (Sweden)

    Matthews Fiona

    2009-07-01

    Full Text Available Abstract Background Little evidence is available to determine which patients should undergo repeat biopsy after initial benign extended core biopsy (ECB. Attempts have been made to reduce the frequency of negative repeat biopsies using PSA kinetics, density, free-to-total ratios and Kattan's nomogram, to identify men more likely to harbour cancer but no single tool accurately predicts biopsy outcome. The objective of this study was to develop a predictive nomogram to identify men more likely to have a cancer diagnosed on repeat prostate biopsy. Methods Patients with previous benign ECB undergoing repeat biopsy were identified from a database. Association between age, volume, stage, previous histology, PSA kinetics and positive repeat biopsy was analysed. Variables were entered stepwise into logistic regression models. A risk score giving the probability of positive repeat biopsy was estimated. The performance of this score was assessed using receiver characteristic (ROC analysis. Results 110 repeat biopsies were performed in this period. Cancer was detected in 31% of repeat biopsies at Hospital (1 and 30% at Hospital (2. The most accurate predictive model combined age, PSA, PSA velocity, free-to-total PSA ratio, prostate volume and digital rectal examination (DRE findings. The risk model performed well in an independent sample, area under the curve (AUCROC was 0.818 (95% CI 0.707 to 0.929 for the risk model and 0.696 (95% CI 0.472 to 0.921 for the validation model. It was calculated that using a threshold risk score of > 0.2 to identify high risk individuals would reduce repeat biopsies by 39% while identifying 90% of the men with prostate cancer. Conclusion An accurate multi-variable predictive tool to determine the risk of positive repeat prostate biopsy is presented. This can be used by urologists in an outpatient setting to aid decision-making for men with prior benign histology for whom a repeat biopsy is being considered.

  13. Biopsies

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Biopsies - Overview A biopsy is the removal of tissue ... What are the limitations of biopsies? What are biopsies? A biopsy is the removal of tissue in ...

  14. Repeated biopsies in patients with prostate cancer on active surveillance

    DEFF Research Database (Denmark)

    Thomsen, Frederik B; Marcussen, Niels; Berg, Kasper D;

    2015-01-01

    were included. The International Society of Urological Pathology 2005 Gleason scoring system was used for the histopathological assessment of all biopsies. Three different definitions of histopathological progression were applied. Unweighted and linear weighted Kappa (κ) statistics were used to compare...... the interobserver agreement. RESULTS: The overall Gleason score agreement was 68.8% with a weighted κ of 0.670. The interobserver agreement was 79.6% for meeting the AS selection criteria. According to the three progression definitions applied, overall agreement was between 80.7% and 89.0% with weighted κ values...

  15. Decreased infiltration of macrophage scavenger receptor-positive cells in initial negative biopsy specimens is correlated with positive repeat biopsies of the prostate.

    Science.gov (United States)

    Nonomura, Norio; Takayama, Hitoshi; Kawashima, Atsunari; Mukai, Masatoshi; Nagahara, Akira; Nakai, Yasutomo; Nakayama, Masashi; Tsujimura, Akira; Nishimura, Kazuo; Aozasa, Katsuyuki; Okuyama, Akihiko

    2010-06-01

    Macrophage scavenger receptor (MSR)-positive inflammatory cells and tumor-associated macrophages (TAMs) have been reported to regulate the growth of various cancers. In this study, the infiltration of MSR-positive cells and TAMs was analyzed to predict the outcome of repeat biopsy in men diagnosed as having no malignancy at the first prostate biopsy. Repeat biopsy of the prostate was carried out in 92 patients who were diagnosed as having no malignancy at the first biopsy. Of these, 30 patients (32.6%) were positive for prostate cancer at the repeat biopsy. Tumor-associated macrophages and MSR-positive cells were immunohistochemically stained with mAbs CD68 and CD204, respectively. Six ocular measuring fields were chosen randomly under a microscope at x400 power in the initial negative biopsy specimens, and the mean TAM and MSR counts for each case were determined. No difference in TAM count was found between the cases with or without prostate cancer. By contrast, the MSR count in patients with cancer was significantly lower than that in patients without cancer at the repeat biopsy (P biopsies, or TAM count. Decreased infiltration of MSR-positive cells in negative first biopsy specimens was correlated with positive findings in the repeat biopsy. The MSR count might be a good indicator for avoiding unnecessary repeat biopsies.

  16. Repeat prostate biopsy accuracy: simulator-based comparison of two- and three-dimensional transrectal US modalities.

    Science.gov (United States)

    Cool, Derek W; Connolly, Michael J; Sherebrin, Shi; Eagleson, Roy; Izawa, Jonathan I; Amann, Justin; Romagnoli, Cesare; Romano, Walter M; Fenster, Aaron

    2010-02-01

    To compare the accuracy of biopsy with two-dimensional (2D) transrectal ultrasonography (US) with that of biopsy with conventional three-dimensional (3D) transrectal US and biopsy with guided 3D transrectal US in the guidance of repeat prostate biopsy procedures in a prostate biopsy simulator. The institutional review board approved this retrospective study. Five residents and five experts performed repeat biopsies with a biopsy simulator that contained the transrectal US prostate images of 10 patients who had undergone biopsy. Simulated repeat biopsies were performed with 2D transrectal US, conventional 3D transrectal US, and guided 3D transrectal US (an extension of 3D transrectal US that enables active display of biopsy targets). The modalities were compared on the basis of time per biopsy and how accurately simulated repeat biopsies could be guided to specific targets. The probability for successful biopsy of a repeat target was calculated for each modality. Guided 3D transrectal US was significantly (P < .01) more accurate for simulated biopsy of repeat targets than was 2D or 3D transrectal US, with a biopsy accuracy of 0.86 mm +/- 0.47 (standard deviation), 3.68 mm +/- 2.60, and 3.60 mm +/- 2.57, respectively. Experts had a 70% probability of sampling a prior biopsy target volume of 0.5 cm(3) with 2D transrectal US; however, the probability approached 100% with guided 3D transrectal US. Biopsy accuracy was not significantly different between experts and residents for any modality; however, experts were significantly (P < .05) faster than residents with each modality. Repeat biopsy of the prostate with 2D transrectal US has limited accuracy. Compared with 2D transrectal US, the biopsy accuracy of both experts and residents improved with guided 3D transrectal US but did not improve with conventional 3D transrectal US.

  17. THE PROGNOSTIC AND DIAGNOSTIC VALUE OF REPEATED TRANSRECTAL PROSTATE SATURATION BIOPSY

    Directory of Open Access Journals (Sweden)

    M. A. Kurdzhiev

    2014-08-01

    Full Text Available Objective: to determine the rate of prostate cancer (PC development after repeated transrectal saturation prostate biopsy (RTRSPB, to study the characteristics of diagnosed tumors, and to estimate their clinical significance from the data of radical retropubic prostatectomy (RRP.Materials and methods. The results of RTRSPB were analyzed in 226 patients with a later evaluation of a tumor from the results of RRP. All the patients underwent at least 2 prostate biopsies (mean 2.4. The average number of biopsy cores was 26.7 (range 24—30. The average value of total prostate-specific antigen before saturation biopsy was 7.5 (range 7.5 to 28.6 ng/ml. The mean age of patients was 62 years (range 53 to 70.  Results. PC was diagnosed in 14.6% of cases (33/226. An isolated lesion of the prostatic transition zone was in 12.1% of cases. If this zone had been excluded from the biopsy scheme, the detection rate of PC during saturation biopsy should be reduced by 13.8%. Better PC detectability during repeated saturation biopsy generally occurred due to the localized forms of the disease (93.3%. The agreement of Gleason tumor grading in the biopsy and prostatectomy specimens was noted in 66.7% of cases.Conclusion. Saturation biopsy allows prediction of a pathological stage of PC, Gleason grade of a tumor and its site localization with a greater probability. Most tumors detectable by saturation biopsy were clinically significant, which makes it possible to recommend RTRSPB to some cohort of high PC-risk patients 

  18. Detection rate of clinically insignificant prostate cancer increases with repeat prostate biopsies

    Institute of Scientific and Technical Information of China (English)

    Bumsoo Park; Seong-Soo Jeon; Sung-Ho Ju; Byong-Chang Jeong; Seong-Il Seo; Hyun-Moo Lee; Han-Yong Choi

    2013-01-01

    To analyze if clinically insignificant prostate cancer (ClPC) is more frequently detected with repeat prostate biopsies,we retrospectively analyzed the records of 2146 men diagnosed with prostate cancer after one or more prostate biopsies.The patients were divided into five groups according to the number of prostate biopsies obtained,e.g.group 1 had one biopsy,group 2 had two biopsies and group 3 had three biopsies.Of the 2146 patients diagnosed with prostate cancer,1956 (91.1%),142 (6.6%),38 (1.8%),9 (0.4%) and 1 (0.1%) men were in groups 1,2,3,4 and 5,respectively.Groups 4 and 5 were excluded because of the small sample sizes.The remaining three groups (groups 1,2 and 3) were statistically analyzed.There were no differences in age or prostate-specific antigen level among the three groups.ClPC was detected in 201 (10.3%),28 (19.7%) and 9 (23.7%) patients in groups 1,2 and 3,respectively (P<0.001).A multivariate analysis showed that the number of biopsies was an independent predictor to detect CIPC (0R=2.688 for group 2; 0R=4.723 for group 3).In conclusion,patients undergoing multiple prostate biopsies are more likely to be diagnosed with CIPC than those who only undergo one biopsy.However,the risk still exists that the patient could have clinically significant prostate cancer.Therefore,when counseling patients with regard to serial repeat biopsies,the possibility of prostate cancer overdiagnosis and overtreatment must be balanced with the continued risk of clinically significant disease.

  19. Thyroid nodules with nondiagnostic results on repeat fine-needle aspiration biopsy: which nodules should be considered for repeat biopsy or surgery rather than follow-up?

    Science.gov (United States)

    2016-01-01

    Purpose: The goal of this study was to assess the clinicopathologic and ultrasonographic features of thyroid nodules with nondiagnostic results on repeat ultrasonography (US)-guided fineneedle aspiration biopsy (FNAB) according to size and the number of suspicious findings and to determine the proper management of nodules with consecutive nondiagnostic results. Methods: This retrospective study included 297 nodules with nondiagnostic results on repeat FNAB that were evaluated by US over the course of at least 12 months of follow-up, a follow-up biopsy, or an operation. We compared clinical and US variables between benign and malignant nodules in thyroid nodules with repeat nondiagnostic results. Results: The comparison of benign and malignant nodules with repeat nondiagnostic results revealed that age, marked hypoechogenicity, irregular or microlobulated margins, microcalcifications, and nonparallel shape were significantly associated with malignancy. Multivariate logistic regression analysis in malignant nodules revealed that microcalcifications and irregular or microlobulated margins were independently associated with malignancy. Among them, only irregular or microlobulated margins were independently significant as a predictor of malignancy in repeatedly nondiagnostic nodules measuring >10 mm. Using receiver operating characteristic analysis, the best cutoff value for the “number of suspicious findings” between benign and malignant nodules was three in nodules of all sizes, three in nodules measuring ≤10 mm, and two in nodules measuring >10 mm. Conclusion: Irregular or microlobulated margins may be the most frequent US features in repeatedly nondiagnostic nodules >10 mm. The presence of “two or more suspicious findings” can be used as the cutoff for distinguishing benign and malignant nodules. PMID:27068131

  20. Thyroid nodules with nondiagnostic results on repeat fine-needle aspiration biopsy: which nodules should be considered for repeat biopsy or surgery rather than follow-up?

    Directory of Open Access Journals (Sweden)

    Na Lae Eun

    2016-07-01

    Full Text Available Purpose: The goal of this study was to assess the clinicopathologic and ultrasonographic features of thyroid nodules with nondiagnostic results on repeat ultrasonography (US-guided fineneedle aspiration biopsy (FNAB according to size and the number of suspicious findings and to determine the proper management of nodules with consecutive nondiagnostic results. Methods: This retrospective study included 297 nodules with nondiagnostic results on repeat FNAB that were evaluated by US over the course of at least 12 months of follow-up, a follow-up biopsy, or an operation. We compared clinical and US variables between benign and malignant nodules in thyroid nodules with repeat nondiagnostic results. Results: The comparison of benign and malignant nodules with repeat nondiagnostic results revealed that age, marked hypoechogenicity, irregular or microlobulated margins, microcalcifications, and nonparallel shape were significantly associated with malignancy. Multivariate logistic regression analysis in malignant nodules revealed that microcalcifications and irregular or microlobulated margins were independently associated with malignancy. Among them, only irregular or microlobulated margins were independently significant as a predictor of malignancy in repeatedly nondiagnostic nodules measuring >10 mm. Using receiver operating characteristic analysis, the best cutoff value for the “number of suspicious findings” between benign and malignant nodules was three in nodules of all sizes, three in nodules measuring ≤10 mm, and two in nodules measuring >10 mm. Conclusion: Irregular or microlobulated margins may be the most frequent US features in repeatedly nondiagnostic nodules >10 mm. The presence of “two or more suspicious findings” can be used as the cutoff for distinguishing benign and malignant nodules.

  1. Thyroid nodules with nondiagnostic results on repeat fine-needle aspiration biopsy: which nodules should be considered for repeat biopsy or surgery rather than follow-up?

    Energy Technology Data Exchange (ETDEWEB)

    Eun, Na Lae; Chang, Hang Seok; Gweon, Hye Mi; Kim, Jeong Ah; Youk, Ji Hyun; Son, Eun Jun [Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Yoo, Mi Ri [Dept. of Radiology, Dongjak Kyunghee Hospital, Seoul (Korea, Republic of); Park, Ah Young [Dept. of Radiology, Korea University Ansan Hospital, Korea University College of Medicine, Ansan (Korea, Republic of); Moon, Hee Jung [Dept. of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2016-07-15

    The goal of this study was to assess the clinicopathologic and ultrasonographic features of thyroid nodules with nondiagnostic results on repeat ultrasonography (US)-guided fineneedle aspiration biopsy (FNAB) according to size and the number of suspicious findings and to determine the proper management of nodules with consecutive nondiagnostic results. This retrospective study included 297 nodules with nondiagnostic results on repeat FNAB that were evaluated by US over the course of at least 12 months of follow-up, a follow-up biopsy, or an operation. We compared clinical and US variables between benign and malignant nodules in thyroid nodules with repeat nondiagnostic results. The comparison of benign and malignant nodules with repeat nondiagnostic results revealed that age, marked hypoechogenicity, irregular or microlobulated margins, microcalcifications, and nonparallel shape were significantly associated with malignancy. Multivariate logistic regression analysis in malignant nodules revealed that microcalcifications and irregular or microlobulated margins were independently associated with malignancy. Among them, only irregular or microlobulated margins were independently significant as a predictor of malignancy in repeatedly nondiagnostic nodules measuring >10 mm. Using receiver operating characteristic analysis, the best cutoff value for the “number of suspicious findings” between benign and malignant nodules was three in nodules of all sizes, three in nodules measuring ≤10 mm, and two in nodules measuring >10 mm. Irregular or microlobulated margins may be the most frequent US features in repeatedly nondiagnostic nodules >10 mm. The presence of “two or more suspicious findings” can be used as the cutoff for distinguishing benign and malignant nodules.

  2. A Prospective Comparison of Selective Multiparametric Magnetic Resonance Imaging Fusion-Targeted and Systematic Transrectal Ultrasound-Guided Biopsies for Detecting Prostate Cancer in Men Undergoing Repeated Biopsies

    DEFF Research Database (Denmark)

    Boesen, Lars; Nørgaard, Nis; Løgager, Vibeke

    2017-01-01

    + 3) cancers (14/64 vs. 41/74) and more patients with intermediate/high-grade cancers (GS ≥3 + 4) (50/64 vs. 33/74) using fewer biopsy cores compared with TRUS-bx (p targeted-only" approach in men with PI-RADS ≥3 lesions reduced the number of men requiring repeated biopsies......INTRODUCTION: The aim of the study was to compare the prostate cancer (PCa) detection rate of systematic transrectal ultrasound-guided biopsies (TRUS-bx) and multiparametric-MRI targeted biopsies (mp-MRI-bx) in a repeat biopsy setting and evaluate the clinical significance following an "MRI-targeted...... by 50%, decreased low-grade cancer diagnoses by 66%, and increased intermediate/high-grade cancer diagnoses by 52%. CONCLUSIONS: MRI-targeted biopsies have a high detection rate for significant PCa in patients with prior negative transrectal ultrasound-guided biopsies and preferentially detect...

  3. Differences between a single session and repeated sessions of 1 Hz TMS by double-cone coil prefrontal stimulation for the improvement of tinnitus.

    Science.gov (United States)

    Vanneste, Sven; De Ridder, Dirk

    2013-03-01

    Tinnitus related distress is associated with increased activity in the anterior cingulate cortex (ACC). In a recent study, it was demonstrated that a single session of low frequency prefrontal TMS using a double-cone coil (DCC) modulating the ACC (AC/DC TMS, anterior cingulate cortex targeted modulation by Double-Cone coil) yields a transient improvement in subjects with chronic tinnitus. An increasing number of studies demonstrated that repeated sessions of low frequency TMS to the temporoparietal area can significantly improve tinnitus complaints. Our aim is to determine the extent to which repeated sessions of AC/DC TMS can modulate tinnitus in comparison to a single session. Seventy-three tinnitus patients received a single (N = 46) or repetitive (N = 27) session(s) of TMS using a DCC placed over the prefrontal cortex. Our results indicate that both single sessions as well as multiple sessions (i.e. 8 sessions) of AC/DC TMS suppress both tinnitus distress (respectively 7.60% vs. 26.19%) and tinnitus intensity (respectively 7.12% vs. 19.60%) transiently. It was further shown that multiple sessions of AC/DC TMS generate a higher suppression effect in comparison to a single session of AC/DC TMS and that more patients responded to repeated sessions of 1 Hz stimulation in comparison to a single session. Our findings give further support to the fact that non-auditory areas are involved in tinnitus intensity and tinnitus distress and that more patients respond to repeated sessions with a higher suppression effect in comparison to patients who received a single session, suggesting that the approach of daily TMS sessions is relevant.

  4. The PICTURE study: diagnostic accuracy of multiparametric MRI in men requiring a repeat prostate biopsy.

    Science.gov (United States)

    Simmons, Lucy A M; Kanthabalan, Abi; Arya, Manit; Briggs, Tim; Barratt, Dean; Charman, Susan C; Freeman, Alex; Gelister, James; Hawkes, David; Hu, Yipeng; Jameson, Charles; McCartan, Neil; Moore, Caroline M; Punwani, Shonit; Ramachandran, Navin; van der Meulen, Jan; Emberton, Mark; Ahmed, Hashim U

    2017-04-25

    Transrectal prostate biopsy has limited diagnostic accuracy. Prostate Imaging Compared to Transperineal Ultrasound-guided biopsy for significant prostate cancer Risk Evaluation (PICTURE) was a paired-cohort confirmatory study designed to assess diagnostic accuracy of multiparametric magnetic resonance imaging (mpMRI) in men requiring a repeat biopsy. All underwent 3 T mpMRI and transperineal template prostate mapping biopsies (TTPM biopsies). Multiparametric MRI was reported using Likert scores and radiologists were blinded to initial biopsies. Men were blinded to mpMRI results. Clinically significant prostate cancer was defined as Gleason ⩾4+3 and/or cancer core length ⩾6 mm. Two hundred and forty-nine had both tests with mean (s.d.) age was 62 (7) years, median (IQR) PSA 6.8 ng ml (4.98-9.50), median (IQR) number of previous biopsies 1 (1-2) and mean (s.d.) gland size 37 ml (15.5). On TTPM biopsies, 103 (41%) had clinically significant prostate cancer. Two hundred and fourteen (86%) had a positive prostate mpMRI using Likert score ⩾3; sensitivity was 97.1% (95% confidence interval (CI): 92-99), specificity 21.9% (15.5-29.5), negative predictive value (NPV) 91.4% (76.9-98.1) and positive predictive value (PPV) 46.7% (35.2-47.8). One hundred and twenty-nine (51.8%) had a positive mpMRI using Likert score ⩾4; sensitivity was 80.6% (71.6-87.7), specificity 68.5% (60.3-75.9), NPV 83.3% (75.4-89.5) and PPV 64.3% (55.4-72.6). In men advised to have a repeat prostate biopsy, prostate mpMRI could be used to safely avoid a repeat biopsy with high sensitivity for clinically significant cancers. However, such a strategy can miss some significant cancers and overdiagnose insignificant cancers depending on the mpMRI score threshold used to define which men should be biopsied.

  5. Clinical utility of the PCA3 urine assay in European men scheduled for repeat biopsy.

    NARCIS (Netherlands)

    Haese, A.; Taille, A de la; Poppel, H van; Marberger, M.; Stenzl, A.; Mulders, P.F.A.; Huland, H.; Abbou, C.C.; Remzi, M.; Tinzl, M.; Feyerabend, S.; Stillebroer, A.B.; Gils, M.P.M.Q.; Schalken, J.A.

    2008-01-01

    BACKGROUND: The Prostate CAncer gene 3 (PCA3) assay has shown promise as an aid in prostate cancer (pCA) diagnosis in identifying men with a high probability of a positive (repeat) biopsy. OBJECTIVE: This study evaluated the clinical utility of the PROGENSA PCA3 assay. DESIGN, SETTING, AND PARTICIPA

  6. Intra-session repeatability of lower limb muscles activation pattern during pedaling.

    Science.gov (United States)

    Dorel, Sylvain; Couturier, Antoine; Hug, François

    2008-10-01

    Assessment of intra-session repeatability of muscle activation pattern is of considerable relevance for research settings, especially when used to determine changes over time. However, the repeatability of lower limb muscles activation pattern during pedaling is not fully established. Thus, we tested the intra-session repeatability of the activation pattern of 10 lower limb muscles during a sub-maximal cycling exercise. Eleven triathletes participated to this study. The experimental session consisted in a reference sub-maximal cycling exercise (i.e. 150 W) performed before and after a 53-min simulated training session (mean power output=200+/-12 W). Repeatability of EMG patterns was assessed in terms of muscle activity level (i.e. RMS of the mean pedaling cycle and burst) and muscle activation timing (i.e. onset and offset of the EMG burst) for the 10 following lower limb muscles: gluteus maximus (GMax), semimembranosus (SM), Biceps femoris (BF), vastus medialis (VM), rectus femoris (RF), vastus lateralis (VL), gastrocnemius medianus (GM) and lateralis (GL), soleus (SOL) and tibialis anterior (TA). No significant differences concerning the muscle activation level were found between test and retest for all the muscles investigated. Only VM, SOL and TA showed significant differences in muscle activation timing parameters. Whereas ICC and SEM values confirmed this weak repeatability, cross-correlation coefficients suggest a good repeatability of the activation timing parameters for all the studied muscles. Overall, the main finding of this work is the good repeatability of the EMG pattern during pedaling both in term of muscle activity level and muscle activation timing.

  7. Targeted histology sampling from atypical small acinar proliferation area detected by repeat transrectal prostate biopsy

    Directory of Open Access Journals (Sweden)

    A. V. Karman

    2017-01-01

    Full Text Available Оbjective: to define the approach to the management of patients with the detected ASAP area.Materials and methods. In the time period from 2012 through 2015, 494 patients with previously negative biopsy and remaining suspicion of prostate cancer (PCa were examined. The patients underwent repeat 24-core multifocal prostate biopsy with taking additional tissue samples from suspicious areas detected by multiparametric magnetic resonance imaging and transrectal ultrasound. An isolated ASAP area was found in 127 (25. 7 % of the 494 examined men. All of them were offered to perform repeat target transrectal biopsy of this area. Targeted transrectal ultrasound guided biopsy of the ASAP area was performed in 56 (44.1 % of the 127 patients, 53 of them being included in the final analysis.Results. PCa was diagnosed in 14 (26.4 % of the 53 patients, their mean age being 64.4 ± 6.9 years. The average level of prostate-specific antigen (PSA in PCa patients was 6.8 ± 3.0 ng/ml, in those with benign lesions – 9.3 ± 6.5 ng/ml; the percentage ratio of free/total PSA with PCa was 16.2 ± 7,8 %, with benign lesions – 23.3 ± 7.7 %; PSA density in PCa patients was 0.14 ± 0.07 ng/ml/cm3, in those with benign lesions – 0.15 ± 0.12 ng/ml/cm3. Therefore, with ASAP area being detected in repeat prostate biopsy samples, it is advisable that targeted extended biopsy of this area be performed. 

  8. Repeated Renal Biopsy - A Predictive Tool to Assess the Probability of Renal Flare in Lupus Nephritis.

    Science.gov (United States)

    Piñeiro, Gastón J; Arrizabalaga, Pilar; Solé, Manel; Abellana, Rosa M; Espinosa, Gerard; Cervera, Ricard

    2016-01-01

    How one responds to treatment of lupus nephritis (LN) is based on clinical features, but the activity in renal biopsy (RB) is uncertain. We have described the therapeutic decisions after performing a repeated RB on the assessment of response to intravenous cyclophosphamide (IC) and the possible prognostic role of this repeated RB. Clinical, laboratory and histological features at the initial RB and repeated RB were analyzed in 35 patients. Data in the initial versus the repeated RB were serum creatinine 1.23 ± 1.08 and 0.96 ± 0.45 mg/dl (p < 0.05), glomerular filtration rate <60 ml/min in 12 and 5% patients and proteinuria 4.1 ± 2.8 vs. 0.6 1.1 g/day (p < 0.05). Significant differences were detected in hematuria, nephrotic syndrome and serological immune features. Complete renal remission was reached in 60% (n = 21) at the time of the repeated RB, partial remission in 31.4% (n = 11), and no response IC in 8.6% (n = 3). Nine patients showed proliferative forms in the repeated RB, 3 of them had proteinuria <1 g/day. Just after the repeated RB, 34.3% increased or started a new immunosuppressive therapy, 17.1% remained with the same complementary IST, and 14.3% decreased or stopped it. In the follow-up post repeated RB, 34.5% without active lesions showed a renal flare versus 77.8% with active lesions (p = 0.04). The mean time was 120 and 45 months, respectively. A repeated biopsy in LN distinguishes patients in true remission from those in apparent remission. By doing this, we can identify patients who could benefit from intensified treatment and for whom unnecessary treatment methods can be modified or eliminated. © 2016 S. Karger AG, Basel.

  9. How repeated 15-minute assertiveness training sessions reduce wrist cutting in patients with borderline personality disorder.

    Science.gov (United States)

    Hayakawa, Masaya

    2009-01-01

    The aim of this work was to examine a possible treatment for patients with borderline personality disorder who have wrist-cutting syndrome, a condition characterized by repeated, superficial wrist cutting in a non-suicidal fashion. Within the current healthcare system in Japan, the average amount of time a doctor can spend with a psychiatric outpatient is about 8 to 15 minutes. We, therefore, examined whether repeated 15-minute psychotherapy sessions to improve patient assertiveness would be effective for reducing wrist cutting and possibly other forms of self-mutilation. We treated 13 patients diagnosed with borderline personality disorder and wrist-cutting syndrome with assertiveness training during 15-minute, biweekly therapy sessions over a course of one to four years. At the conclusion of psychotherapeutic treatment, 69% of outpatients showed a statistically significant reduction in wrist-cutting behavior.

  10. Addressing the need for repeat prostate biopsy: new technology and approaches.

    Science.gov (United States)

    Blute, Michael L; Abel, E Jason; Downs, Tracy M; Kelcz, Frederick; Jarrard, David F

    2015-08-01

    No guidelines currently exist that address the need for rebiopsy in patients with a negative diagnosis of prostate cancer on initial biopsy sample analysis. Accurate diagnosis of prostate cancer in these patients is often complicated by continued elevation of serum PSA levels that are suggestive of prostate cancer, resulting in a distinct management challenge. Following negative initial findings of biopsy sample analysis, total serum PSA levels and serum PSA kinetics are ineffective indicators of a need for a repeat biopsy; therefore, patients suspected of having prostate cancer might undergo several unnecessary biopsy procedures. Several alternative strategies exist for identifying men who might be at risk of prostate cancer despite negative findings of biopsy sample analysis. Use of other serum PSA-related measurements enables more sensitive and specific diagnosis and can be combined with knowledge of clinicopathological features to improve outcomes. Other options include the FDA-approved Progensa(®) test and prostate imaging using MRI. Newer tissue-based assays that measure methylation changes in normal prostate tissue are currently being developed. A cost-effective strategy is proposed in order to address this challenging clinical scenario, and potential directions of future studies in this area are also described.

  11. Evaluation of Histopathological Changes in Control Biopsies Which Taken 48 Sessions after NBUVB Phototherapy for Early-Stage Mycosis Fungoides

    Directory of Open Access Journals (Sweden)

    Ebru Zemheri

    2012-01-01

    Full Text Available Background. There are not many studies investigating histomorphological changes in 48 sessions in patients with early-stage MF after narrowband UVB (NBUVB treatment. Our purpose is to evaluate histological features of phototherapy after 48 sessions and determine which parameters are more reliable for controlling skin biopsies. Methods. Biopsies of 32 patients with early stage of MF, who were treated with NBUVB phototherapy, were histologically evaluated before and after the treatments, including epidermotropism, stratum corneum, epidermal thickness, dermal infiltration, papillary dermal fibrosis, vascular alterations, and other dermal changes. We discuss the histomorphological effects of NBUVB phototherapy on skin biopsies by comparing the responders with nonresponders, with before and after the treatment. Results. 9 patients (28% did not give any response to treatment. Alleviation in epidermotropism, increases in parakeratosis and normal keratosis, perivascular infiltration, and melanophages, decrease in the lichenoid/patchy lichenoid infiltration pattern after the treatment was statistically significant. Comparing by response, normalization of stratum corneum and epidermis, orthohyperkeratosis, decrease in linearly arranged cells, the lichenoid/patchy lichenoid infiltration, the loss of inflammation were statistically significant in responders group. Conclusion. We detected a significant decrease in linearly arranged cells after phototherapy, indicating that it is an “important diagnostic parameter" in evaluation of therapeutic response.

  12. Evaluation of T2-weighted and dynamic contrast-enhanced MRI in localizing prostate cancer before repeat biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Cheikh, Alexandre Ben; Girouin, Nicolas [Hopital Edouard Herriot, Hospices Civils de Lyon, Department of Urinary and Vascular Radiology, Lyon (France)]|[Universite de Lyon, Lyon (France)]|[Universite de Lyon 1, faculte de medecine Lyon Nord, Lyon (France); Colombel, Marc; Marechal, Jean-Marie [Hopital Edouard Herriot, Hospices Civils de Lyon, Department of Urology, Lyon (France); Gelet, Albert [Hopital Edouard Herriot, Hospices Civils de Lyon, Department of Urology, Lyon (France)]|[Inserm, U556, Lyon (France); Bissery, Alvine; Rabilloud, Muriel [Hospices Civils de Lyon, Department of Biostatistics, Lyon (France)]|[Universite de Lyon 1, UMR CNRS 5558, Laboratoire Biostatistiques-Sante, Pierre-Benite (France); Lyonnet, Denis [Hopital Edouard Herriot, Hospices Civils de Lyon, Department of Urinary and Vascular Radiology, Lyon (France)]|[Universite de Lyon, Lyon (France)]|[Universite de Lyon 1, faculte de medecine Lyon Nord, Lyon (France)]|[Inserm, U556, Lyon (France); Rouviere, Olivier [Hopital Edouard Herriot, Hospices Civils de Lyon, Department of Urinary and Vascular Radiology, Lyon (France)]|[Universite de Lyon, Lyon (France)]|[Universite de Lyon 1, faculte de medecine Lyon Nord, Lyon (France)]|[Inserm, U556, Lyon (France)]|[Hopital Edouard Herriot, Department of Urinary and Vascular Radiology, Pavillon P Radio, Lyon Cedex 03 (France)

    2009-03-15

    We assessed the accuracy of T2-weighted (T2w) and dynamic contrast-enhanced (DCE) 1.5-T magnetic resonance imaging (MRI) in localizing prostate cancer before transrectal ultrasound-guided repeat biopsy. Ninety-three patients with abnormal PSA level and negative prostate biopsy underwent T2w and DCE prostate MRI using pelvic coil before repeat biopsy. T2w and DCE images were interpreted using visual criteria only. MR results were correlated with repeat biopsy findings in ten prostate sectors. Repeat biopsy found prostate cancer in 23 patients (24.7%) and 44 sectors (6.6%). At per patient analysis, the sensitivity, specificity, positive and negative predictive values were 47.8%, 44.3%, 20.4% and 79.5% for T2w imaging and 82.6%, 20%, 24.4% and 93.3% for DCE imaging. When all suspicious areas (on T2w or DCE imaging) were taken into account, a sensitivity of 82.6% and a negative predictive value of 100% could be achieved. At per sector analysis, DCE imaging was significantly less specific (83.5% vs. 89.7%, p < 0.002) than T2w imaging; it was more sensitive (52.4% vs. 32.1%), but the difference was hardly significant (p = 0.09). T2w and DCE MRI using pelvic coil and visual diagnostic criteria can guide prostate repeat biopsy, with a good sensitivity and NPV. (orig.)

  13. Probability modeling of the number of positive cores in a prostate cancer biopsy session, with applications.

    Science.gov (United States)

    Serfling, Robert; Ogola, Gerald

    2016-02-10

    Among men, prostate cancer (CaP) is the most common newly diagnosed cancer and the second leading cause of death from cancer. A major issue of very large scale is avoiding both over-treatment and under-treatment of CaP cases. The central challenge is deciding clinical significance or insignificance when the CaP biopsy results are positive but only marginally so. A related concern is deciding how to increase the number of biopsy cores for larger prostates. As a foundation for improved choice of number of cores and improved interpretation of biopsy results, we develop a probability model for the number of positive cores found in a biopsy, given the total number of cores, the volumes of the tumor nodules, and - very importantly - the prostate volume. Also, three applications are carried out: guidelines for the number of cores as a function of prostate volume, decision rules for insignificant versus significant CaP using number of positive cores, and, using prior distributions on total tumor size, Bayesian posterior probabilities for insignificant CaP and posterior median CaP. The model-based results have generality of application, take prostate volume into account, and provide attractive tradeoffs of specificity versus sensitivity. Copyright © 2015 John Wiley & Sons, Ltd.

  14. Postprandial Responses to Lipid and Carbohydrate Ingestion in Repeated Subcutaneous Adipose Tissue Biopsies in Healthy Adults

    Directory of Open Access Journals (Sweden)

    Aimee L. Dordevic

    2015-07-01

    Full Text Available Adipose tissue is a primary site of meta-inflammation. Diet composition influences adipose tissue metabolism and a single meal can drive an inflammatory response in postprandial period. This study aimed to examine the effect lipid and carbohydrate ingestion compared with a non-caloric placebo on adipose tissue response. Thirty-three healthy adults (age 24.5 ± 3.3 year (mean ± standard deviation (SD; body mass index (BMI 24.1 ± 3.2 kg/m2, were randomised into one of three parallel beverage groups; placebo (water, carbohydrate (maltodextrin or lipid (dairy-cream. Subcutaneous, abdominal adipose tissue biopsies and serum samples were collected prior to (0 h, as well as 2 h and 4 h after consumption of the beverage. Adipose tissue gene expression levels of monocyte chemoattractant protein-1 (MCP-1, interleukin 6 (IL-6 and tumor necrosis factor-α (TNF-α increased in all three groups, without an increase in circulating TNF-α. Serum leptin (0.6-fold, p = 0.03 and adipose tissue leptin gene expression levels (0.6-fold, p = 0.001 decreased in the hours following the placebo beverage, but not the nutrient beverages. Despite increased inflammatory cytokine gene expression in adipose tissue with all beverages, suggesting a confounding effect of the repeated biopsy method, differences in metabolic responses of adipose tissue and circulating adipokines to ingestion of lipid and carbohydrate beverages were observed.

  15. Postprandial Responses to Lipid and Carbohydrate Ingestion in Repeated Subcutaneous Adipose Tissue Biopsies in Healthy Adults.

    Science.gov (United States)

    Dordevic, Aimee L; Pendergast, Felicity J; Morgan, Han; Villas-Boas, Silas; Caldow, Marissa K; Larsen, Amy E; Sinclair, Andrew J; Cameron-Smith, David

    2015-07-01

    Adipose tissue is a primary site of meta-inflammation. Diet composition influences adipose tissue metabolism and a single meal can drive an inflammatory response in postprandial period. This study aimed to examine the effect lipid and carbohydrate ingestion compared with a non-caloric placebo on adipose tissue response. Thirty-three healthy adults (age 24.5 ± 3.3 year (mean ± standard deviation (SD)); body mass index (BMI) 24.1 ± 3.2 kg/m2, were randomised into one of three parallel beverage groups; placebo (water), carbohydrate (maltodextrin) or lipid (dairy-cream). Subcutaneous, abdominal adipose tissue biopsies and serum samples were collected prior to (0 h), as well as 2 h and 4 h after consumption of the beverage. Adipose tissue gene expression levels of monocyte chemoattractant protein-1 (MCP-1), interleukin 6 (IL-6) and tumor necrosis factor-α (TNF-α) increased in all three groups, without an increase in circulating TNF-α. Serum leptin (0.6-fold, p = 0.03) and adipose tissue leptin gene expression levels (0.6-fold, p = 0.001) decreased in the hours following the placebo beverage, but not the nutrient beverages. Despite increased inflammatory cytokine gene expression in adipose tissue with all beverages, suggesting a confounding effect of the repeated biopsy method, differences in metabolic responses of adipose tissue and circulating adipokines to ingestion of lipid and carbohydrate beverages were observed.

  16. Early experience with multiparametric magnetic resonance imaging-targeted biopsies under visual transrectal ultrasound guidance in patients suspicious for prostate cancer undergoing repeated biopsy

    DEFF Research Database (Denmark)

    Boesen, Lars; Noergaard, Nis; Chabanova, Elizaveta

    2015-01-01

    -RADS) and Likert classification. All underwent repeated TRUS-bx (10 cores) and mp-MRI-bx under visual TRUS guidance of any mp-MRI-suspicious lesion not targeted by systematic TRUS-bx. RESULTS: PCa was found in 39 out of 83 patients (47%) and mp-MRI identified at least one lesion with some degree of suspicion...... in all 39 patients. Both PI-RADS and Likert scoring showed a high correlation between suspicion of malignancy and biopsy results (p

  17. Gene expression in human skeletal muscle: alternative normalization method and effect of repeated biopsies.

    Science.gov (United States)

    Lundby, Carsten; Nordsborg, Nikolai; Kusuhara, Keiko; Kristensen, Kristina Møller; Neufer, P Darrell; Pilegaard, Henriette

    2005-10-01

    The reverse transcriptase-polymerase chain reaction (RT-PCR) method has lately become widely used to determine transcription and mRNA content in rodent and human muscle samples. However, the common use of endogenous controls for correcting for variance in cDNA between samples is not optimal. Specifically, we investigated (1) a new normalization method based on determining the cDNA content by the flourophores PicoGreen and OliGreen, (2) effect of repeated muscle biopsies on mRNA gene expression, and (3) the spatial heterogeneity in mRNA expression across the muscle. Standard curves using oligo standards revealed a high degree of sensitivity and linearity (2.5-45 ng; R2>0.99) with OliGreen reagent, as was the case for OliGreen analyses with standard curves constructed from serial dilutions of representative RT samples (R2 >0.99 for a ten times dilution range of a representative reversed transcribed (RT) sample). Likewise, PicoGreen reagent detected the RNA:DNA hybrid content in RT samples with great sensitivity. Standard curves constructed from both double-stranded lambda DNA (1-10 ng) and from serial dilutions of representative RT samples consistently resulted in linearity with R2 >0.99. The present determination of cDNA content in reversed transcribed human skeletal muscle RNA samples by both PicoGreen and OliGreen analyses suggests that these fluorophores provide a potential alternative normalization procedure for human gene expression studies. In addition, the present study shows that multiple muscle biopsies obtained from the same muscle do not influence the mRNA response induced by an acute exercise bout for any of the genes examined.

  18. A new technique for repeated biopsies of the mammary gland in dairy cows allotted to Latin-square design studies.

    Science.gov (United States)

    de Lima, Luciano S; Martineau, Eric; De Marchi, Francilaine E; Palin, Marie-France; Dos Santos, Geraldo T; Petit, Hélène V

    2016-07-01

    The objective of this study was to develop a technique for carrying out repeated biopsies of the mammary gland of lactating dairy cows that provides enough material to monitor enzyme activities and gene expression in mammary secretory tissue. A total of 16 Holstein cows were subjected to 4 mammary biopsies each at 3-week intervals for a total of 64 biopsies. A 0.75-cm incision was made through the skin and subcutaneous tissue of the mammary gland and a trocar and cannula were inserted using a circular motion. The trocar was withdrawn and a syringe was plugged into the base of the cannula to create a vacuum for sampling mammary tissue. To reduce bleeding, hand pressure was put on the surgery site after biopsy and skin closure and ice was applied for at least 2 h after the biopsy using a cow bra. The entire procedure took an average of 25 min. Two attempts were usually enough to obtain 800 mg of tissue. Visual examination of milk samples 10 d after the biopsy indicated no trace of blood, except in samples from 2 cows. All wounds healed without infection and subcutaneous hematomas resorbed within 7 d. There was no incidence of mastitis throughout the lactation. This technique provides a new tool for biopsy of the mammary gland repeated at short intervals with the main effect being a decrease in milk production. Although secondary complications leading to illness or death are always a risk with any procedure, this biopsy technique was carried out without complications to the health of animals and with no incidence of mastitis during the lactation.

  19. Combination of repeated single-session percutaneous ethanol injection and transarterial chemoembolisation compared to repeated single-session percutaneous ethanol injection in patients with non-resectable hepatocellular carcinoma

    Institute of Scientific and Technical Information of China (English)

    Arne Dettmer; Susanne Krusche; Sonja Merkesdal; Michael Galanski; Michael P Manns; Joerg S Bleck; Timm D Kirchhoff; Michael Gebel; Lars Zender; Nisar P Malek; Bernhard Panning; Ajay Chavan; Herbert Rosenthal; Stefan Kubicka

    2006-01-01

    AIM: To evaluate the treatment effect of percutaneous ethanol injection (PEI) for patients with advanced,non-resectable HCC compared with combination of transarterial chemoembolisation (TACE) and repeated single-session PEI, repeated single-session PEI alone,repeated TACE alone, or best supportive care.METHODS: All patients who received PEI treatment during the study period were included and stratified to one of the following treatment modalities according to physical status and tumor extent: combination of TACE and repeated single-session PEI, repeated single-session PEI alone, repeated TACE alone, or best supportive care. Prognostic value of clinical parameters including Okuda-classification, presence of portal vein thrombosis,presence of ascites, number of tumors, maximum tumor diameter, and serum cholinesterase (CHE), as well as Child-Pugh stage, α-fetoprotein (AFP), fever, incidence of complications were assessed and compared between the groups. Survival was determined using Kaplan-Meier and multivariate regression analyses.RESULTS: The 1- and 3-year survival of all patients was 73% and 47%. In the subgroup analyses, the combination of TACE and PEI (1) was associated with a longer survival (1-, 3-, 5-year survival: 90%, 52%,and 43%) compared to PEI treatment alone (2) (1-, 3-,5-year survival:65%, 50%, and 37%). Secondary PEI after initial stratification to TACE (3) yielded comparable results (1-, 3-, 5-year survival: 91%, 40%, and 30%)while PEI after stratification to best supportive care (4)was associated with decreased survival (1-, 3-, 5-year survival: 50%, 23%, 12%). Apart from the chosen treatment modalities, predictors for better survival were tumor number (n<5), tumor size (<5cm), no ascites before PEI, and stable serum cholinesterase after PEI (P<0.05). The mortality within 2 wk after PEI was 2.8%(n=3). There were 24 (8.9%) major complications after PEI including segmental liver infarction, focal liver necrosis, and liver abscess. All

  20. Acute phase response in the primiparous dairy cows after repeated percutaneous liver biopsy during the transition period.

    Science.gov (United States)

    Jawor, P; Brzozowska, A; Słoniewski, K; Kowalski, Z M; Stefaniak, T

    2016-01-01

    The aim of this study was to evaluate the acute phase response of dairy cows to repeated liver biopsy in order to estimate the safety of this procedure during the transition period. Liver biopsies (up to 1000 mg of liver tissue) were conducted twice a day, 7 days before expected parturition and 3 days after calving. The number of needle insertions for each biopsy was recorded and was dependent on the amount of obtained tissue. Blood samples were taken on day 7 before expected parturition, then on days 3, 4, 7 and 14 after calving. Body temperature was measured daily in all 30 cows from day 3 until day 14 after calving. The concentrations of haptoglobin, serum amyloid A, fibrinogen and interleukin-6 were determined in serum and plasma. In 16.7% of cows, the rectal body temperature rose by ≥ 0.5°C on the day after liver biopsy. Although the concentrations of haptoglobin, serum amyloid A and fibrinogen increased significantly after calving (pbiopsies on the acute phase reaction and repeated biopsy during the transition period had no effect on body temperature. Therefore, the procedure may be regarded as safe for cows during the transition period.

  1. Application of transrectal ultrasound-guided repeat needle biopsy in the diagnosis of prostate cancer in Chinese population: A retrospective study

    Directory of Open Access Journals (Sweden)

    Yi Wang

    2016-01-01

    Full Text Available Background: Transrectal ultrasound-guided repeat needle biopsy (TUGRNB is widely used for diagnosis of prostate cancer (PCa. However, significance of TUGRNB in Chinese population was rarely reported. A retrospective study was conducted to evaluate the significance of TUGRNB applied in prediction of PCa in Chinese population. Materials and Methods: A total of 960 from January 2009 to December 2012 were included. Repeat needle biopsy rate and PCa positive detection rate were evaluated. Relationship between prostate specific antigen (PSA levels and PCa positive rates was analyzed. Results: PCa positive detection rate after initial needle biopsy was 28.4%, which was lower than the rate of repeat needle biopsy (40%. The rate for immediate transurethral resection (TUR, surgery after initial needle biopsy, was 27.1%, however with a low PCa positive detection rate (0.66%. The repeat needle biopsy rate was lower compared with the initial biopsy rate (P 20 ng/ml, PCa positive rate was significantly higher than those with PSA < 20 ng/ml (P < 0.05. Conclusion: PCa positive detection rate following repeat needle biopsy in Chinese population was higher, although the repeated needle biopsy rate was still in a low level. TUGRNB should attract more attention in the diagnosis of PCa.

  2. Repeat biopsy in patients with initial diagnosis of PIN; La biopsia ripetuta nei pazienti con diagnosi iniziale di PIN

    Energy Technology Data Exchange (ETDEWEB)

    De Matteis, Massimo [Azienda Ospedaliera Policlinico S. Orsola-Malpighi, Bologna (Italy). UO Radiologia Albertoni; Poggi, Cristina; De Martino, Antonietta; Pavlica, Pietro [Azienda Ospedaliera Policlinico S. Orsola-Malpighi, Bologna (Italy). UO Radiologia Palagi, Dipartimento area radiologica; Corti, Barbara [Azienda Ospedaliera Policlinico S. Orsola-Malpighi, Bologna (Italy). UO Anatomia ed istologia patologica, Dipartimento oncologico ed ematologico; Barozzi, Libero [Azienda Ospedaliera Policlinico S. Orsola-Malpighi, Bologna (Italy). UO Radiologia d' urgenza, Dipartimento emergenze ed accettazione

    2005-09-15

    Purpose. Prostatic intra-epithelial neoplasia (PIN) is considered a pre-malignant lesion and the main precursor of invasive prostatic adenocarcinoma. A PIN diagnosis established by prostate needle biopsy poses a difficult clinical management. problem. We retrospectively reviewed our three-year experience in order to identify criteria for referring patients to repeat biopsy. Materials and methods. We reviewed the repeat biopsy records of 72 patients in whom PIN had been detected on initial US-guided needle biopsy of the prostate. All the patients had a minimum of 6 biopsy cores taken, and they all had PSA > 4 ng/ml. Results. Adenocarcinoma was detected in 15 patients out of 50 (30%) with an initial diagnosis of low-grade PIN and in 10 patients out of 22 (45.4%) with high grade PIN, in 7 out of 18 (39%) in whom PSA levels had decreased during the observation interval, in 16 patients out of 46 (35%) in whom the PSA had increased and in 2 patients out of 8 (25%) with stable PSA. Conclusions. Our results seem to confirm that PIN can be considered a precursor of prostatic adenocarcinoma or a histological alteration often associated with it. Patients with low-grade PIN and particularly those with high-grade PIN should be regularly subjected to repeat biopsy at short intervals due to the high frequency of the final diagnosis of carcinoma. No agreement has been reached on the time interval between the first and the second biopsy. The PSA changes during the observation period are not a statistically significant parameter to suggest the repetition of prostatic biopsy. [Italian] Scopo. La neoplasia prostatica intraepiteliale (PIN) e considerata una lesione premaligna ed il precursore principale dell'adenocarcinoma prostatico infiltrante. La diagnosi di PIN ottenuta con l'agobiopsia della prostata rappresenta un difficile problema gestionale clinico. In una valutazione retrospettiva della nostra esperienza di 3 anni si e cercato di individuare i criteri che possano

  3. Optimal timing for a repeat fine-needle aspiration biopsy of thyroid nodule following an initial nondiagnostic fine-needle aspiration.

    Science.gov (United States)

    Deniwar, Ahmed; Hammad, AbdulRahman Y; Ali, Daniah Bu; Alsaleh, Nuha; Lahlouh, Maha; Sholl, Andrew B; Moroz, Krzysztof; Aslam, Rizwan; Thethi, Tina; Kandil, Emad

    2017-02-01

    In the case of a nondiagnostic thyroid fine-needle aspiration (FNA) biopsy result, recent guidelines from the Bethesda system recommend repeat thyroid FNA after 3 months to prevent false-positive results. We aimed to examine our institutional data to determine whether the 3-month period affects the diagnostic yield of repeat biopsies. A retrospective review of patient records over a 5-year period at our institution was performed. Patients who required repeat FNA due to nondiagnostic results were included. The time between the FNA biopsies, adequacy of the FNA specimens, as well as the surgical pathology diagnosis were analyzed. We identified 317 patients who required a repeat FNA. Of these, 96 (30.3%) patients had repeat FNAs less than 3 months after initial biopsy, while 221 (69.7%) patients had repeat FNAs in greater than 3 months. One hundred five patients were referred to our clinic with an initial nondiagnostic biopsy from an outside institution. Repeat FNA was nondiagnostic in 35 patients (11.04%) in the total study population. There was no difference in satisfactory diagnostic yield between repeat FNAs performed greater than 3 months (201 patients, 90.95%) or less than 3 months (81 patients, 84.38%) after the initial biopsy (P = .117). Of the 35 patients with repeat nondiagnostic biopsy, 17 patients underwent diagnostic lobectomy and 3 (17.6%) patients were found to have malignant disease. Early (biopsy interval would alleviate stress on patients with benign nodules and expedite surgical intervention in patients with malignancy. Published by Elsevier Inc.

  4. Affective Responses to Repeated Sessions of High-Intensity Interval Training.

    Science.gov (United States)

    Saanijoki, Tiina; Nummenmaa, Lauri; Eskelinen, Jari-Joonas; Savolainen, Anna M; Vahlberg, Tero; Kalliokoski, Kari K; Hannukainen, Jarna C

    2015-12-01

    Vigorous exercise feels unpleasant, and negative emotions may discourage adherence to regular exercise. We quantified the subjective affective responses to short-term high-intensity interval training (HIT) in comparison with moderate-intensity continuous training (MIT). Twenty-six healthy middle-age (mean age, 47 ± 5 yr; mean VO2peak, 34.2 ± 4.1 mL·kg⁻¹·min⁻¹) sedentary men were randomized into HIT (n = 13, 4-6 × 30 s of all-out cycling efforts at approximately 180% of peak workload with 4-min recovery) or MIT (n = 13, 40- to 60-min continuous cycling at 60% of peak workload) groups, performing six sessions within two weeks. Perceived exertion, stress, and affective state were recorded before, during, and after each session. Perceived exertion and arousal were higher, and affective state, more negative during the HIT than that during MIT sessions (P training. Peak oxygen consumption increased (P training). Short-term HIT and MIT are equally effective in improving aerobic fitness, but HIT increases experience of negative emotions and exertion in sedentary middle-age men. This may limit the adherence to this time-effective training mode, even though displeasure lessens over time and suggests similar mental adaptations to both MIT and HIT.

  5. Within-session effect of repeated stress exposure on extinction circuitry function in social anxiety disorder.

    Science.gov (United States)

    Åhs, Fredrik; Gingnell, Malin; Furmark, Tomas; Fredrikson, Mats

    2017-03-30

    Anxiety reduction following repeated exposure to stressful experiences is generally held to depend on neural processes involved in extinction of conditioned fear. We predicted that repeated exposure to stressful experiences would change activity throughout the circuitry serving extinction, including ventromedial prefrontal cortex (vmPFC), the hippocampus and the amygdala. To test this prediction, 36 participants diagnosed with SAD performed two successive speeches in front of an observing audience while regional cerebral blood flow (rCBF) was recorded using positron emission tomography. To control for non-anxiolytic effects of repeated exposure, rCBF was also measured during repeated presentations of neutral and angry facial expressions. Results showed that anxiety ratings and heart rate decreased from the first to the second speech, indicating an anxiolytic effect of repeated exposure. Exposure attenuated rCBF in the amygdala whereas no change in rCBF was observed in the vmPFC or hippocampus. The rCBF-reductions in the amygdala were greater following repetition of the speech task than repetition of face exposure indicating that they were specific to anxiety attenuation and not due to a reduced novelty. Our findings suggest that amygdala-related attenuation processes are key to understanding the working mechanisms of exposure therapy.

  6. Repeated sessions of transcranial direct current stimulation evaluation on fatigue and daytime sleepiness in Parkinson's disease.

    Science.gov (United States)

    Forogh, Bijan; Rafiei, Maryam; Arbabi, Amin; Motamed, Mohammad Reza; Madani, Seyed Pezhman; Sajadi, Simin

    2017-02-01

    Parkinson is a common and disabling disease that affects patient's and career's quality of life. Unfortunately, medications, such as dopaminergic and sedative-hypnotic drugs, as an effective treatment have unwilling side effects. Recently, Transcranial Direct Current Stimulation (tDCS) in conjunction with medication becomes popular as a complementary safe treatment and several studies have proved its effectiveness on controlling motor and specially non-motor aspects of Parkinson's disease. In this randomized double-blind parallel study, 23 patients with Parkinson's disease divided into two groups of real tDCS plus occupational therapy and sham tDCS plus occupational therapy and the effects of therapeutic sessions (eight sessions tDCS with 0.06 mA/cm(2) current, 20 min on dorsolateral prefrontal cortex) were evaluated on fatigue and daytime sleepiness just after therapeutic course and in 3-month follow-up. tDCS had a significant effect on fatigue and no effect on daytime sleepiness reduction in patients with Parkinson's disease. tDCS is an effective and safe complementary treatment on fatigue reduction in Parkinson's disease.

  7. Effect of the number of sprint repetitions on the variation of blood lactate concentration in repeated sprint sessions.

    Science.gov (United States)

    Gharbi, Z; Dardouri, W; Haj-Sassi, R; Castagna, C; Chamari, K; Souissi, N

    2014-06-01

    The aim of the present study was to examine the effect of number of sprint repetitions on the variation of blood lactate concentration (blood [La]) during different repeated-sprint sessions in order to find the appropriate number of sprint repetitions that properly simulates the physiological demands of team sport competitions. Twenty male team-sport players (age, 22.2 ± 2.9 years) performed several repeated-sprint sessions (RSS) consisting of 1, 2, 3, 4, 5, 9, or 10 repetitions of 30 m shuttle sprints (2 × 15 m) with 30 s recovery in between. The blood [La] was obtained after 3 min of recovery at the end of each RSS. The present study showed that for RSS of 3 sprints (RSS3) there was a high increase (psprints (9.6±1.4 and 10.5±1.9 mmol · l(-1), p=0.96 and 0.26, respectively). After RSS9 and RSS10 blood [La] further significantly increased to 12.6 and 12.7 mmol · l(-1), psprint speed decrement (Sdec) (1.5±1.2; 2.0±1.1 and 2.6±1.4%, respectively). There was also no significant difference between RSS9 and RSS10 for Sdec (3.9±1.3% and 4.5±1.4%, respectively). In conclusion, the repeated-sprint protocol composed of 5 shuttle sprint repetitions is more representative of the blood lactate demands of the team sports game intensity.

  8. Accuracy of 3 Tesla pelvic phased-array multiparametric MRI in diagnosing prostate cancer at repeat biopsy

    Directory of Open Access Journals (Sweden)

    Pietro Pepe

    2014-12-01

    Full Text Available Introduction. Multiparametric pelvic magnetic resonance imaging (mpMRI accuracy in prostate cancer (PCa diagnosis was evaluated. Materials and Methods. From June 2011 to December 2013, 168 patients (median 65 years with negative digital rectal examination underwent repeat transperineal saturation biopsy (SPBx; median 28 cores for persistently high or increasing PSA values, PSA >10 ng/ml or PSA values between 4.1-10 o r 2.6-4 ng/ml with free/total PSA < 25% and < 20%, respectively. All patients underwent mpMRI using a 3.0 Tesla scanner equipped with surface 16 channels phased-array coil and lesions suspicious for PCa were submitted to additional targeted biopsies. Results. A T1c PCa was found in 66 (39% cases; SPBx and mpMRI-suspicious targeted biopsy diagnosed 60 (91% and 52 (78.8% cancers missing 6 (all of the anterior zone and 14 cancers (12 and 2 of the lateral margins and anterior zone, respectively; in detail, mpMRI missed 12 (18.1% PCa charaterized by microfocal (1 positive core with greatest percentage of cancer and Gleason score equal to 5% and 6, respectively disease at risk for insignificant cancer. The diameter of the suspicious mpMRI lesion was directly correlated to the diagnosis of PCa with poor Gleason score (p < 0.05; detection rate of cancer for each suspicious mpMRI core was 35.3%. Diagnostic accuracy, sensitivity, specificity, positive and negative predictive value of mpMRI in diagnosing PCa was 75.7%, 82.5%, 71.8%, 78.9%, 87.9%, respectively. Conclusion. Multiparametric pMRI improved SPBx accuracy in diagnosing significant anterior PCa; the diameter of mpMRI suspicious lesion resulted significantly predictive of aggressive cancers.

  9. Thyroid nodules with initially non-diagnostic, fine-needle aspiration results: comparison of core-needle biopsy and repeated fine-needle aspiration.

    Science.gov (United States)

    Choi, Sang Hyun; Baek, Jung Hwan; Lee, Jeong Hyun; Choi, Young Jun; Hong, Min Ji; Song, Dong Eun; Kim, Jae Kyun; Yoon, Jong Ho; Kim, Won Bae

    2014-11-01

    To evaluate the role of core-needle biopsy (CNB) by comparing the results of CNB and repeated fine-needle aspiration (FNA) for thyroid nodules with initially non-diagnostic FNA results. From October 2008 to December 2011, 360 nodules - 180 consecutive repeated FNAs and 180 consecutive CNBs -- from 360 patients (83 men, 277 women; mean age, 54.4 years) with initially non-diagnostic FNA results were analyzed retrospectively. The incidence of non-diagnostic results, inconclusive results, diagnostic surgery, and diagnostic performance of repeated FNA and CNB were assessed, and factors affecting second non-diagnostic results were evaluated. CNB achieved a significantly lower non-diagnostic and inconclusive rate than repeated FNA (1.1 % versus 40.0 %, P needle biopsy achieved a lower number of non-diagnostic and inconclusive results. • Core-needle biopsy achieved better diagnostic performance. • Use of core-needle biopsy could prevent unnecessary diagnostic surgery. • Repeated fine-needle aspiration was significantly associated with a second non-diagnosis.

  10. Repeatability of and relationship between potential COPD biomarkers in bronchoalveolar lavage, bronchial biopsies, serum, and induced sputum.

    Directory of Open Access Journals (Sweden)

    Stefan Röpcke

    Full Text Available Chronic Obstructive Pulmonary Disease (COPD is a chronic inflammatory disease, primarily affecting the airways. Stable biomarkers characterizing the inflammatory phenotype of the disease, relevant for disease activity and suited to predict disease progression are needed to monitor the efficacy and safety of drug interventions. We therefore analyzed a large panel of markers in bronchoalveolar lavage, bronchial biopsies, serum and induced sputum of 23 healthy smokers and 24 smoking COPD patients (GOLD II matched for age and gender. Sample collection was performed twice within a period of 6 weeks. Assays for over 100 different markers were validated for the respective matrices prior to analysis. In our study, we found 51 markers with a sufficient repeatability (intraclass correlation coefficient >0.6, most of these in serum. Differences between groups were observed for markers from all compartments, which extends (von-Willebrand-factor and confirms (e.g. C-reactive-protein, interleukin-6 previous findings. No correlations between lung and serum markers were observed, including A1AT. Airway inflammation defined by sputum neutrophils showed only a moderate repeatability. This could be improved, when a combination of neutrophils and four sputum fluid phase markers was used to define the inflammatory phenotype.In summary, our study provides comprehensive information on the repeatability and interrelationship of pulmonary and systemic COPD-related markers. These results are relevant for ongoing large clinical trials and future COPD research. While serum markers can discriminate between smokers with and without COPD, they do not seem to sufficiently reflect the disease-associated inflammatory processes within the airways.

  11. Core-needle biopsy versus repeat fine-needle aspiration for thyroid nodules initially read as atypia/follicular lesion of undetermined significance.

    Science.gov (United States)

    Choi, Young Jun; Baek, Jung Hwan; Suh, Chong Hyun; Shim, Woo Hyun; Jeong, Boseul; Kim, Jae Kyun; Song, Dong Eun; Kim, Tae Yong; Chung, Ki-Wook; Lee, Jeong Hyun

    2017-02-01

    The purpose of this study was to evaluate the role of core-needle biopsy (CNB) by comparing the results of CNB and repeat fine-needle aspiration (FNA) for thyroid nodules that are initially read as atypia/follicular lesion of undetermined significance (AUS/FLUS) on FNA. Among 2631 initial AUS/FLUS FNA results, 505 consecutive nodules (295 repeat FNAs and 210 CNBs) were retrospectively analyzed. The primary outcome was inconclusive (ie, nondiagnostic or AUS/FLUS). The secondary outcomes included inconclusive results of the subcategory, risk factors for inconclusive results, and diagnostic performance. CNB demonstrated significantly fewer inconclusive results than repeat FNA for the overall nodules (40.9% vs 63%; p < .001). Repeat FNA and group FLUS were significant risk factors for inconclusive results (odds ratio = 1.92; p =.001 and odds ratio = 2.08; p <.001, respectively). All diagnostic performances using CNB were higher than repeat FNAs. CNB is more useful than repeat FNAs for reducing inconclusive results and improving the diagnostic performance of thyroid nodules with initial AUS/FLUS FNA results. © 2016 Wiley Periodicals, Inc. Head Neck 39: 361-369, 2017. © 2016 Wiley Periodicals, Inc.

  12. The PCA3 test for guiding repeat biopsy of prostate cancer and its cut-off score: a systematic review and meta-analysis

    Directory of Open Access Journals (Sweden)

    Yong Luo

    2014-06-01

    Full Text Available The specificity of prostate-specific antigen (PSA for early intervention in repeat biopsy is unsatisfactory. Prostate cancer antigen 3 (PCA3 may be more accurate in outcome prediction than other methods for the early detection of prostate cancer (PCa. However, the results were inconsistent in repeated biopsies. Therefore, we performed a systematic review and meta-analysis to evaluate the role of PCA3 in outcome prediction. A systematic bibliographic search was conducted for articles published before April 2013, using PubMed, Medline, Web of Science, Embase and other databases from health technology assessment agencies. The quality of the studies was assessed on the basis of QUADAS criteria. Eleven studies of diagnostic tests with moderate to high quality were selected. A meta-analysis was carried out to synthesize the results. The results of the meta-analyses were heterogeneous among studies. We performed a subgroup analysis (with or without inclusion of high-grade prostatic intraepithelial neoplasia (HGPIN and atypical small acinar proliferation (ASAP. Using a PCA3 cutoff of 20 or 35, in the two sub-groups, the global sensitivity values were 0.93 or 0.80 and 0.79 or 0.75, specificities were 0.65 or 0.44 and 0.78 or 0.70, positive likelihood ratios were 1.86 or 1.58 and 2.49 or 1.78, negative likelihood ratios were 0.81 or 0.43 and 0.91 or 0.82 and diagnostic odd ratios (ORs were 5.73 or 3.45 and 7.13 or 4.11, respectively. The areas under the curve (AUCs of the summary receiver operating characteristic curve were 0.85 or 0.72 and 0.81 or 0.69, respectively. PCA3 can be used for repeat biopsy of the prostate to improve accuracy of PCa detection. Unnecessary biopsies can be avoided by using a PCa cutoff score of 20.

  13. The PCA3 test for guiding repeat biopsy of prostate cancer and its cut-off score:a systematic review and meta-analysis

    Institute of Scientific and Technical Information of China (English)

    Yong Luo; Xin Gou; Peng Huang; Chan Mou

    2014-01-01

    The speciifcity of prostate-speciifc antigen (PSA) for early intervention in repeat biopsy is unsatisfactory. Prostate cancer antigen 3 (PCA3) may be more accurate in outcome prediction than other methods for the early detection of prostate cancer (PCa). However, the results were inconsistent in repeated biopsies. Therefore, we performed a systematic review and meta-analysis to evaluate the role of PCA3 in outcome prediction. A systematic bibliographic search was conducted for articles published before April 2013, using PubMed, Medline, Web of Science, Embase and other databases from health technology assessment agencies. The quality of the studies was assessed on the basis of QUADAS criteria. Eleven studies of diagnostic tests with moderate to high quality were selected. A meta-analysis was carried out to synthesize the results. The results of the meta-analyses were heterogeneous among studies. We performed a subgroup analysis (with or without inclusion of high-grade prostatic intraepithelial neoplasia (HGPIN) and atypical small acinar proliferation (ASAP)). Using a PCA3 cutoff of 20 or 35, in the two sub-groups, the global sensitivity values were 0.93 or 0.80 and 0.79 or 0.75, speciifcities were 0.65 or 0.44 and 0.78 or 0.70, positive likelihood ratios were 1.86 or 1.58 and 2.49 or 1.78, negative likelihood ratios were 0.81 or 0.43 and 0.91 or 0.82 and diagnostic odd ratios (ORs) were 5.73 or 3.45 and 7.13 or 4.11, respectively. The areas under the curve (AUCs) of the summary receiver operating characteristic curve were 0.85 or 0.72 and 0.81 or 0.69, respectively. PCA3 can be used for repeat biopsy of the prostate to improve accuracy of PCa detection. Unnecessary biopsies can be avoided by using a PCa cutoff score of 20.

  14. Suction-modified needle biopsy technique for the human soleus muscle.

    Science.gov (United States)

    Cotter, Joshua A; Yu, Alvin; Kreitenberg, Arthur; Haddad, Fadia H; Baker, Michael J; Fox, John C; Adams, Gregory R

    2013-10-01

    The needle biopsy technique for the soleus muscle is of particular interest because of the muscle's unique fiber type distribution, contractile properties, and sensitivity to unloading. Unlike other commonly biopsied muscles, the soleus is not fully superficial and is in close proximity to neurovascular structures, resulting in a more challenging biopsy. Because of this, a standardized protocol for performing needle biopsies on the human soleus muscle that is safe, reliable, and repeatable is presented. Ultrasonography was used on an initial set of 12 subjects to determine the optimal biopsy zone, thereby guiding the location of the incision site. There were 45 subjects recruited who attended 2 separate biopsy sessions. Each biopsy session incorporated 3 passes of the biopsy needle proximal, posterior, and distal using suction from a portable vacuum source producing 3 separate muscle specimens. There were 84 soleus muscle biopsy procedures which were successfully conducted yielding 252 total samples without complication. Ultrasonography was used to confirm biopsy needle infiltration of the soleus muscle. Average sample weight obtained per pass was 61.5 +/- 15.7 mg. Histochemistry and molecular analyses demonstrated a considerably higher amount of slow type I MHC in comparison to the vastus lateralis, providing verification for the successful sampling of the soleus muscle. The procedure presented consists of a detailed protocol to accurately and consistently obtain muscle biopsy samples from the human soleus muscle. We have demonstrated that the human soleus biopsy is a safe, reliable, and repeatable procedure providing ample tissue for multiple types of analyses.

  15. Inter-subject, inter-ocular and inter-session repeatability of the photopic negative response of the electroretinogram recorded using DTL and skin electrodes.

    Science.gov (United States)

    Mortlock, Katharine E; Binns, Alison M; Aldebasi, Yousef H; North, Rachel V

    2010-10-01

    The photopic negative response (PhNR) has attracted interest as a flash ERG component reflecting inner retinal activity, with investigators adopting various approaches to analysing the response. This study has two principal aims: first to determine the most reliable technique for assessing the PhNR amplitude; secondly to compare the repeatability characteristics of the PhNR recorded using DTL and skin active electrodes. Electroretinograms were recorded in 31 subjects, using both electrode types, in response to a Ganzfeld red stimulus (Lee filter "bright red"; 1.76 log phot td.s; 4 Hz) presented over a steady blue background (Schott glass filter BG28; 3.9 log scot td). Sixteen subjects returned to assess repeatability. PhNR amplitude was measured from b-wave peak-to-PhNR trough, pre-stimulus baseline to trough, and from peak and baseline to a fixed time-point; a ratio of b-wave/PhNR amplitude was also calculated. Coefficients of variation (CoV), and inter-ocular and inter-session limits of agreement (LoA) were calculated for all measures. The ratio of b-wave/PhNR amplitude showed the lowest CoV (14.3% DTL; 23.2% skin), inter-ocular LoA (22.2% DTL; 25.0% skin), and inter-session LoA (22.8% DTL; 20.3% skin). The peak-to-trough and peak-to-fixed-time measurements were also consistently reliable. Least reliable measures were those measured from baseline. While skin electrode responses were significantly smaller than DTL responses (P < 0.0001), the variability was only slightly increased. This study suggests that peak-to-trough measurements are the most reliable means of measuring the PhNR and ratio calculation further improves repeatability. Skin electrodes provided a viable alternative to DTL electrodes for recording the PhNR.

  16. Bone Biopsy

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Bone Biopsy Bone biopsy uses a needle and imaging ... the limitations of Bone Biopsy? What is a Bone Biopsy? A bone biopsy is an image-guided ...

  17. Prospective comparison of T2w-MRI and dynamic-contrast-enhanced MRI, 3D-MR spectroscopic imaging or diffusion-weighted MRI in repeat TRUS-guided biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Portalez, Daniel [Clinique Pasteur, 45, Department of Radiology, Toulouse (France); Rollin, Gautier; Mouly, Patrick; Jonca, Frederic; Malavaud, Bernard [Hopital de Rangueil, Department of Urology, Toulouse Cedex 9 (France); Leandri, Pierre [Clinique Saint Jean, 20, Department of Urology, Toulouse (France); Elman, Benjamin [Clinique Pasteur, 45, Department of Urology, Toulouse (France)

    2010-12-15

    To compare T2-weighted MRI and functional MRI techniques in guiding repeat prostate biopsies. Sixty-eight patients with a history of negative biopsies, negative digital rectal examination and elevated PSA were imaged before repeat biopsies. Dichotomous criteria were used with visual validation of T2-weighted MRI, dynamic contrast-enhanced MRI and literature-derived cut-offs for 3D-spectroscopy MRI (choline-creatine-to-citrate ratio >0.86) and diffusion-weighted imaging (ADC x 10{sup 3} mm{sup 2}/s < 1.24). For each segment and MRI technique, results were rendered as being suspicious/non-suspicious for malignancy. Sextant biopsies, transition zone biopsies and at least two additional biopsies of suspicious areas were taken. In the peripheral zones, 105/408 segments and in the transition zones 19/136 segments were suspicious according to at least one MRI technique. A total of 28/68 (41.2%) patients were found to have cancer. Diffusion-weighted imaging exhibited the highest positive predictive value (0.52) compared with T2-weighted MRI (0.29), dynamic contrast-enhanced MRI (0.33) and 3D-spectroscopy MRI (0.25). Logistic regression showed the probability of cancer in a segment increasing 12-fold when T2-weighted and diffusion-weighted imaging MRI were both suspicious (63.4%) compared with both being non-suspicious (5.2%). The proposed system of analysis and reporting could prove clinically relevant in the decision whether to repeat targeted biopsies. (orig.)

  18. 重复穿刺活检中高级别上皮内瘤对前列腺癌的预测价值%Prediction value of high-grade prostatic intraepithelial neoplasia for prostate cancer on repeat biopsies

    Institute of Scientific and Technical Information of China (English)

    Huilian Hou; Xuebin Zhang; Xu Li; Xingfa Chen; Chunbao Wang; Guanjun Zhang; Honghan Wang; Huilin Gong; Yuan Deng; Min Wang

    2011-01-01

    Objective: The significance of isolated high-grade prostatic intraepithelial neoplasia in initial biopsy as an predictor for prostate cancer has been extensively research, and the true relationship remnant is no clear till now. The aim of this study is to evaluate prediction value of cancer on repeat biopsy in patients with high-grade prostatic intraepithelial neoplasia,using multivariate analysis. Methods: Thirty-eight men with a diagnosis of isolated high-grade prostatic intraepithelial neoplasia in initial needle biopsy were studies, in the Fist Affiliated Hospital of Medical School of Xi'an Jiaotong University, from January 2003 to March 2009. These samples were using immunostaining of p63 and 34βE12 and P504s, with a median follow-up of 525 (range, 7 to 1650) days, and to researched the incidence of subsequent prostate cancer, and to predicted the risk of prostate cancer in clinicopathological parameters of isolated high-grade prostatic intraepithelial neoplasia on repeat biopsies by logistic regression analysis. Results: There were 10 of 38 (26.3%) men with prostate cancer on repeat biopsies after diagnosis isolated high-grade prostatic intraepithelial neoplasia in initial biopsy, of the rates of prostate cancer were 80% for micropapillary and 75% for cribriform high-grade prostatic intraepithelial neoplasia (P < 0.05), respectively. The positive cores of isolated high-grade prostatic intraepithelial neoplasia was the important for the risk of prostate cancer using Multifactor logistic regression analysis. The time range in 30 to 690 days was stronger risk for prostate cancer detection after diagnosis isolated HGPIN in initial biopsy. p63 and 34βE12 were disrupted positive expression, and P504S was weak positive expression in the 61% isolated high-grade prostatic intraepithelial neoplasia. Conclusion: Isolated high-grade prostatic intraepithelial neoplasia on repeat biopsy conferred a 26.3% risk of prostate cancer, and this risk level is lower than the

  19. Gum biopsy

    Science.gov (United States)

    Biopsy - gingiva (gums) ... used to close the opening created for the biopsy. ... to eat for a few hours before the biopsy. ... Risks for this procedure include: Bleeding from the biopsy site Infection of the gums Soreness

  20. Skin Biopsy

    Science.gov (United States)

    ... I Help Someone Who's Being Bullied? Volunteering Skin Biopsy KidsHealth > For Teens > Skin Biopsy Print A A ... español Biopsia de piel What Is a Skin Biopsy and Who Would Need One? In a biopsy, ...

  1. Repeat Targeted Prostate Biopsy under Guidance of Multiparametric MRI-Correlated Real-Time Contrast-Enhanced Ultrasound for Patients with Previous Negative Biopsy and Elevated Prostate-Specific Antigen: A Prospective Study

    Science.gov (United States)

    Jang, Dong Ryul; Jung, Dae Chul; Oh, Young Taik; Noh, Songmi; Han, Kyunghwa; Kim, Kiwook; Rha, Koon-Ho; Choi, Young Deuk; Hong, Sung Joon

    2015-01-01

    Objectives To prospectively determine whether multi-parametric MRI (mpMRI) - contrast-enhanced ultrasound (CEUS) correlated, imaging-guided target biopsy (TB) method could improve the detection of prostate cancer in re-biopsy setting of patients with prior negative biopsy. Methods From 2012 to 2014, a total of 42 Korean men with a negative result from previous systematic biopsy (SB) and elevated prostate-specific antigen underwent 3T mpMRI and real-time CEUS guided TB. Target lesions were determined by fusion of mpMRI and CEUS. Subsequently, 12-core SB was performed by a different radiologist. We compared core-based cancer detection rates (CaDR) using the generalized linear mixed model (GLIMMIX) for each biopsy method. Results Core-based CaDR was higher in TB (17.92%, 38 of 212 cores) than in SB (6.15%, 31 of 504 cores) (p biopsy of patients with prior negative biopsy can improve CaDR based on the number of cores taken. PMID:26083348

  2. Liver biopsy

    Science.gov (United States)

    Biopsy - liver; Percutaneous biopsy ... the biopsy needle to be inserted into the liver. This is often done by using ultrasound. The ... the chance of damage to the lung or liver. The needle is removed quickly. Pressure will be ...

  3. Nerve biopsy

    Science.gov (United States)

    Biopsy - nerve ... A nerve biopsy is most often done on a nerve in the ankle, forearm, or along a rib. The health care ... feel a prick and a mild sting. The biopsy site may be sore for a few days ...

  4. Biopsy - polyps

    Science.gov (United States)

    Polyp biopsy ... are treated is the colon. How a polyp biopsy is done depends on the location: Colonoscopy or flexible sigmoidoscopy explores the large bowel Colposcopy-directed biopsy examines the vagina and cervix Esophagogastroduodenoscopy (EGD) or ...

  5. Bladder biopsy

    Science.gov (United States)

    Biopsy - bladder ... A bladder biopsy can be done as part of a cystoscopy . Cystoscopy is a telescopic examination of the inside of the ... informed consent form before you have a bladder biopsy. In most cases, you are asked to urinate ...

  6. Synovial biopsy

    Science.gov (United States)

    Biopsy - synovial membrane ... fluid in and out of the area. A biopsy grasper is inserted through the trocar and turned ... Synovial biopsy helps diagnose gout and bacterial infections, or rule out other infections. It can be used to diagnose ...

  7. Intrasubject reproducibility of prefrontal cortex activities during a verbal fluency task over two repeated sessions using multi-channel near-infrared spectroscopy.

    Science.gov (United States)

    Kakimoto, Yu; Nishimura, Yukika; Hara, Naomi; Okada, Motohiro; Tanii, Hisashi; Okazaki, Yuji

    2009-08-01

    To determine whether intrasubject reproducibility could be observed in the frontal cortex and to assess the mental-health status of subjects in each session. We measured changes in oxygenated hemoglobin concentration ([oxy-Hb]) during a letter version of the verbal fluency task using near-infrared spectroscopy imaging in twenty healthy adults over two sessions approximately two months apart. Additionally, the mental-health status of the subjects in each session was evaluated according to the State-Trait Anxiety Inventory, the Zung Self-rating Depression Scale, the Profile of Mood States, and the revised edition of the Neuroticism-Extroversion-Openness Personality Inventory. The association between those scores and [oxy-Hb] changes during the verbal fluency task in each session was investigated. Performance on the verbal fluency task was about equal across the two sessions, and frontal activation during the task was observed globally in approximately the same region. In the test-retest reliability, acceptable values were shown in both the Intraclass Correlation Coefficients of the mean [oxy-Hb] changes and the correlation coefficients of the whole waveforms for each subject in the two sessions. Mental-health status as measured by several questionnaires was within the healthy range, and no correlation with the frontal activation was seen, except in several channels. The current results suggest that the measurement experience exerted very little influence, except for in a very small region. In addition, the intrasubject reproducibility of frontal activation measured by multi-channel near-infrared spectroscopy was well demonstrated in mentally healthy subjects at intervals of two months.

  8. Tongue biopsy

    Science.gov (United States)

    Biopsy - tongue ... A tongue biopsy can be done using a needle. You will get numbing medicine at the place where the ... provider will gently stick the needle into the tongue and remove a tiny piece of tissue. Some ...

  9. Needle Biopsy

    Science.gov (United States)

    ... for a day or two During the needle biopsy Your health care team will position you in ... if you're feeling uncomfortable. After the needle biopsy Once your doctor has collected enough cells or ...

  10. Transjugular liver biopsy.

    Science.gov (United States)

    Ble, Michel; Procopet, Bogdan; Miquel, Rosa; Hernandez-Gea, Virginia; García-Pagán, Juan Carlos

    2014-11-01

    Liver biopsy is still the gold standard for evaluation of acute and chronic liver diseases, despite achievements regarding noninvasive diagnosis and staging in liver diseases. Transjugular liver biopsy (TJLB) has proved a good option when ascites and/or significant coagulopathy precludes a percutaneous approach. Because diagnostic hemodynamic procedures can be performed during the same session, it is useful in many clinical settings, regardless of the absence of percuteaneous contraindications. TJLB is a safe technique able to provide good-quality specimens with a low rate of complications. This article presents an overview of TJLB that discusses the technique, applicability, indications, contraindications, complications, and diagnostic accuracy.

  11. Does Obesity Modify the Ability of Prebiopsy Prostate Specific Antigen to Detect Prostate Cancer on Repeat Biopsy? Results from the REDUCE Study.

    Science.gov (United States)

    Vidal, Adriana C; Howard, Lauren E; Moreira, Daniel M; Castro-Santamaria, Ramiro; Andriole, Gerald L; Freedland, Stephen J

    2015-07-01

    Higher body mass index is linked to lower prostate specific antigen. This has given rise to concerns that prostate specific antigen may be less reliable for predicting prostate cancer among obese men. We tested the accuracy of prebiopsy prostate specific antigen for predicting prostate cancer across body mass index categories. We used the REDUCE study, which tested dutasteride for prostate cancer risk reduction in men with a prostate specific antigen of 2.5 to 10.0 ng/ml and a negative pre-study biopsy. All men were required to have a biopsy at 2 and 4 years independent of prostate specific antigen. We assessed the performance of prebiopsy prostate specific antigen to predict overall and high grade prostate cancer (Gleason sum 7 or greater) in each body mass index group using AUC. Of 6,103 men who had a 2-year biopsy 1,646 (27%) were normal weight, 3,209 (53%) were overweight and 1,248 (20%) were obese. Mean adjusted prostate specific antigen for normal weight, overweight and obese subjects on placebo was 7.73, 7.17 and 6.79 ng/ml (p-trend=0.192), and on dutasteride 3.16, 2.93 and 2.62 ng/ml (p=0.008). AUC analysis using raw prostate specific antigen data for predicting prostate cancer ranged from 0.60 to 0.64 in the placebo arm and 0.58 to 0.66 in the dutasteride arm with no difference across body mass index categories (p-interactions ≥0.212). Similar results were found for high grade prostate cancer with AUC ranging from 0.69 to 0.70 in the placebo arm and 0.65 to 0.75 in the dutasteride arm but no differences across body mass index categories (p-interactions ≥0.157). Among men with a previous negative biopsy the accuracy of prebiopsy prostate specific antigen to predict overall and high grade prostate cancer was independent of body mass index. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  12. Needs Session Outline.

    Science.gov (United States)

    1980-06-12

    into two groups 5.5.2 Assign the most likely theme scenario to both groups 5.5.3 Each group selects a session recorder 5.5.4 Using Brainwriting in...of the two remaining theme scenarios. 5.5.10 Repeat steps (3) through (8) except that the group that used Brainwriting for the first scenario should

  13. Comparison of initial and tertiary centre second opinion reads of multiparametric magnetic resonance imaging of the prostate prior to repeat biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, Nienke L. [University Hospital RWTH Aachen, Department of Diagnostic and Interventional Radiology, Aachen (Germany); Addenbrooke' s Hospital and University of Cambridge, CamPARI Clinic, Cambridge (United Kingdom); Koo, Brendan C.; Gallagher, Ferdia A. [Addenbrooke' s Hospital and University of Cambridge, CamPARI Clinic, Cambridge (United Kingdom); Addenbrooke' s Hospital and University of Cambridge, Department of Radiology, Cambridge (United Kingdom); Warren, Anne Y. [Addenbrooke' s Hospital and University of Cambridge, CamPARI Clinic, Cambridge (United Kingdom); Addenbrooke' s Hospital, Department of Pathology, Cambridge (United Kingdom); Doble, Andrew; Gnanapragasam, Vincent; Bratt, Ola; Kastner, Christof [Addenbrooke' s Hospital and University of Cambridge, CamPARI Clinic, Cambridge (United Kingdom); Addenbrooke' s Hospital, Department of Urology, Cambridge (United Kingdom); Barrett, Tristan [Addenbrooke' s Hospital and University of Cambridge, CamPARI Clinic, Cambridge (United Kingdom); Addenbrooke' s Hospital and University of Cambridge, Department of Radiology, Cambridge (United Kingdom); University of Cambridge School of Clinical Medicine, Department of Radiology, Box 218, Cambridge (United Kingdom)

    2017-06-15

    To investigate the value of second-opinion evaluation of multiparametric prostate magnetic resonance imaging (MRI) by subspecialised uroradiologists at a tertiary centre for the detection of significant cancer in transperineal fusion prostate biopsy. Evaluation of prospectively acquired initial and second-opinion radiology reports of 158 patients who underwent MRI at regional hospitals prior to transperineal MR/untrasound fusion biopsy at a tertiary referral centre over a 3-year period. Gleason score (GS) 7-10 cancer, positive predictive value (PPV) and negative (NPV) predictive value (±95 % confidence intervals) were calculated and compared by Fisher's exact test. Disagreement between initial and tertiary centre second-opinion reports was observed in 54 % of cases (86/158). MRIs had a higher NPV for GS 7-10 in tertiary centre reads compared to initial reports (0.89 ± 0.08 vs 0.72 ± 0.16; p = 0.04), and a higher PPV in the target area for all cancer (0.61 ± 0.12 vs 0.28 ± 0.10; p = 0.01) and GS 7-10 cancer (0.43 ± 0.12 vs 0.2 3 ± 0.09; p = 0.02). For equivocal suspicion, the PPV for GS 7-10 was 0.12 ± 0.11 for tertiary centre and 0.11 ± 0.09 for initial reads; p = 1.00. Second readings of prostate MRI by subspecialised uroradiologists at a tertiary centre significantly improved both NPV and PPV. Reporter experience may help to reduce overcalling and avoid overtargeting of lesions. (orig.)

  14. SATURATION BIOPSY OF THE PROSTATE (REVIEW

    Directory of Open Access Journals (Sweden)

    A. V. Sadchenko

    2014-07-01

    Full Text Available Prostate biopsy is the principal method of diagnois of prostate cancer, allowing to start the adequate treatment. The tactics of the patients, which have negative initial biopsy, is a subject of discussion. Saturation biopsy is a “gold standard„ of diagnostics of PCA with repeat biopsy. Saturation biopsy of the prostate is not a primary procedure, usually apply in patients with negative biopsies in anamnesis, patients with multifocal PIN and ASAP. Saturation biopsy allows to more precisely predict the volume and degree of malignancy of PCA, that can be used for planning tactics of active surveillance and focal therapy.

  15. Panel Session

    DEFF Research Database (Denmark)

    Bertelsen, Olav Wedege

    2004-01-01

    In this panel session, four researchers will discuss the role of a theoretical foundation, in particular AT, in the design of information technology based artefacts. The general discussion will take of from a specific examination of the ActAD approach.......In this panel session, four researchers will discuss the role of a theoretical foundation, in particular AT, in the design of information technology based artefacts. The general discussion will take of from a specific examination of the ActAD approach....

  16. Minimal-invasive magnetic heating of tumors does not alter intra-tumoral nanoparticle accumulation, allowing for repeated therapy sessions: an in vivo study in mice

    Science.gov (United States)

    Kettering, Melanie; Richter, Heike; Wiekhorst, Frank; Bremer-Streck, Sibylle; Trahms, Lutz; Alois Kaiser, Werner; Hilger, Ingrid

    2011-12-01

    Localized magnetic heating treatments (hyperthermia, thermal ablation) using superparamagnetic iron oxide nanoparticles (MNPs) continue to be an active area of cancer research. For generating the appropriate heat to sufficiently target cell destruction, adequate MNP concentrations need to be accumulated into tumors. Furthermore, the knowledge of MNP bio-distribution after application and additionally after heating is significant, firstly because of the possibility of repeated heating treatments if MNPs remain at the target region and secondly to study potential adverse effects dealing with MNP dilution from the target region over time. In this context, little is known about the behavior of MNPs after intra-tumoral application and magnetic heating. Therefore, the present in vivo study on the bio-distribution of intra-tumorally injected MNPs in mice focused on MNP long term monitoring of pre and post therapy over seven days using multi-channel magnetorelaxometry (MRX). Subsequently, single-channel MRX was adopted to study the bio-distribution of MNPs in internal organs and tumors of sacrificed animals. We found no distinct change of total MNP amounts in vivo during long term monitoring. Most of the MNP amounts remained in the tumors; only a few MNPs were detected in liver and spleen and less than 1% of totally injected MNPs were excreted. Apparently, the application of magnetic heating and the induction of apoptosis did not affect MNP accumulation. Our results indicate that MNP mainly remained within the injection side after magnetic heating over a seven-days-observation and therefore not affecting healthy tissue. As a consequence, localized magnetic heating therapy of tumors might be applied periodically for a better therapeutic outcome.

  17. Kidney Biopsy

    Science.gov (United States)

    ... Care Provider People should talk with their health care provider about medical conditions they have and all prescribed and over- ... biopsy, a person should talk with their health care provider about medical conditions and allergies they have and all medications ...

  18. Panel Sessions.

    Science.gov (United States)

    Proceedings of the ASIS Mid-Year Meeting, 1992

    1992-01-01

    Lists the speakers and summarizes the issues addressed for 12 panel sessions on topics related to networking, including libraries and national networks, federal national resources and energy programs, multimedia issues, telecommuting, remote image serving, accessing the Internet, library automation, scientific information, applications of Z39.50,…

  19. Lymph node biopsy

    Science.gov (United States)

    Biopsy - lymph nodes; Open lymph node biopsy; Fine needle aspiration biopsy; Sentinel lymph node biopsy ... A lymph node biopsy is done in an operating room in a hospital. Or, it is done at an outpatient surgical center. The ...

  20. Image guided versus palpation guided core needle biopsy of palpable breast masses: a prospective study

    Directory of Open Access Journals (Sweden)

    Smriti Hari

    2016-01-01

    Interpretation & conclusions: Our results showed that in palpable breast masses, image guided biopsy was superior to palpation guided biopsy in terms of sensitivity, false negative rate and repeat biopsy rates.

  1. Nasal mucosal biopsy

    Science.gov (United States)

    Biopsy - nasal mucosa; Nose biopsy ... to fast for a few hours before the biopsy. ... Nasal mucosal biopsy is usually done when abnormal tissue is seen during examination of the nose. It may also be done ...

  2. Biopsy - biliary tract

    Science.gov (United States)

    Cytology analysis - biliary tract; Biliary tract biopsy ... A sample for a biliary tract biopsy can be obtained in different ways. A needle biopsy can be done if you have a well-defined tumor. The biopsy site ...

  3. Cold knife cone biopsy

    Science.gov (United States)

    ... squamous cells - cone biopsy; Pap smear - cone biopsy; HPV - cone biopsy; Human papilloma virus - cone biopsy; Cervix - ... exam. The health care provider will place an instrument (speculum) into your vagina to better see the ...

  4. Bone lesion biopsy

    Science.gov (United States)

    Bone biopsy; Biopsy - bone ... needle is gently pushed and twisted into the bone. Once the sample is obtained, the needle is ... sample is sent to a lab for examination. Bone biopsy may also be done under general anesthesia ...

  5. Bone biopsy (image)

    Science.gov (United States)

    A bone biopsy is performed by making a small incision into the skin. A biopsy needle retrieves a sample of bone and it ... examination. The most common reasons for bone lesion biopsy are to distinguish between benign and malignant bone ...

  6. Muscle biopsy (image)

    Science.gov (United States)

    A muscle biopsy involves removal of a plug of tissue usually by a needle to be later used for examination. Sometimes ... there is a patchy condition expected an open biopsy may be used. Open biopsy involves a small ...

  7. Skin lesion biopsy

    Science.gov (United States)

    ... procedure will leave a small indented area. This type of biopsy is often done when a skin cancer is ... may have stitches to close the area. This type of biopsy is often done to diagnose rashes . EXCISIONAL BIOPSY ...

  8. The influence of the leader on the movement of the horse in walking during repeated hippotherapy sessions [Vliv vodiče na pohyb koně v kroku v opakovaných lekcích hipoterapie

    Directory of Open Access Journals (Sweden)

    Tereza Dvořáková

    2009-09-01

    Full Text Available BACKGROUND: The movement of a walking horse is utilized as a tool for a therapeutic effect in hippotherapy. The movement impulses of the horse's back are influenced by the movement action of its limbs, morphology, speed of walk, etc. OBJECTIVE: The aim of the study was to evaluate the influence of the leader on a horse's movement while walking during repeated hippotherapy treatment sessions. METHODS: Three dimensional (3D videography was used for the assessment of the movements of a horse (selected points on the limbs and back and a human being (reaction to the horse's movement. The study was done with the repeated measurements (n = 6 of the movement of horses (n = 2 and riders (n = 12 during five weeks of hippotherapy intervention (9 sessions in total by the different leaders (n = 6 of the horses. RESULTS: There are differences in the range of movement of selected points on the limbs and back of the horse while leading it as done by different leaders (p < 0.05, p < 0.01. The changes in the kinematics of the horse's limbs are transmitted to the horseback movements of horse H1 only within a limited range. The range of the differences on the limbs and back for horse H2 is similar. The movement responses of healthy riders show differences in the lower part of the spine (p < 0.05; in the upper part of the spine the differences are minimal. The horse leader is one of the key factors for adhering to the desired medical effect, which is established on the basis of the intervention of physiotherapy throughout hippotherapy. CONCLUSIONS: As there are a number of factors which could have a negative effect on the movement of the horse (weather, disturbing influences of the environment, low quality surface, the activities of the horse leader in keeping the relevant direction and speed of the horse's movement are decisive factors. This study emphasises the significance of the role of the horse leader in therapy and puts stress on his/her level of

  9. Biopsy with the New Essen Biopsy Forceps

    Directory of Open Access Journals (Sweden)

    Peter G. Traine

    2013-01-01

    Full Text Available Purpose. To present initial experience with a novel biopsy method, the Essen biopsy forceps. Therefore, two patients with diagnostic suspicion of uveal melanoma underwent biopsy for histopathological confirmation. Case Presentation. Two patients presented with painless unilateral vision reduction. Ultrasound revealed the diagnostic suspicion of uveal melanoma. Therefore, biopsy with the Essen biopsy forceps using a sutureless 23-gauge three-port vitrectomy system was performed. The specimens were then submitted to a pathologist and processed. Histopathology of the obtained specimen confirmed the diagnostic suspicion of choroid melanoma in both patients. Conclusion. Essen biopsy forceps is a very practicable alternative method to the FNAB, allowing a combined histopathological and immunohistochemical examination for achieving high diagnostic accuracy at minimal risk.

  10. Post-Session Authentication

    DEFF Research Database (Denmark)

    Ahmed, Naveed; Jensen, Christian D.

    2012-01-01

    . In this paper, we consider the case of post-session authentication, where parties authenticate each other at the end of their interactive session. This use of authentication is different from session-less authentication (e.g., in RFID) and pre-session authentication (e.g., for access control.) Post...

  11. Prostate biopsy strategies: current state of the art.

    Science.gov (United States)

    Mian, Badar M

    2004-05-01

    Prostate-specific antigen testing and prostate biopsy have revolutionized our ability to detect prostate cancer at an early stage. The transrectal ultrasound-guided biopsy procedure has undergone a number of modifications over the past 10 years to meet our goal of early detection of cancer at a curable stage. Biopsy schemes have evolved from lesion-directed biopsies to systematic mapping of the peripheral zone of the prostate, which harbors almost all of the significant tumor foci. An increase in the number of biopsy cores from 6 to 10 (or 12) has resulted in a significant improvement in the detection of clinically localized cancer, without any appreciable increase in the number of indolent cancers. Current biopsy schemes also have enhanced our ability to determine the true prognostic value of pathologic lesions such as high-grade prostatic intraepithelial neoplasia and atypical small acinar proliferation which have been associated with cancer detection in repeat biopsies. I discuss the rationale behind, and the outcomes of, various biopsy strategies. More than 15 years after PSA testing was popularized for early detection, a number of men are presenting for evaluation regarding repeat prostate biopsy for various clinical indications. The indications, biopsy scheme, and cancer detection rates for repeat prostate biopsy are discussed in detail.

  12. Sentinel node biopsy (image)

    Science.gov (United States)

    Sentinel node biopsy is a technique which helps determine if a cancer has spread (metastasized), or is contained locally. When a ... is closest to the cancer site. Sentinel node biopsy is used to stage many kinds of cancer, ...

  13. Mediastinoscopy with biopsy

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003864.htm Mediastinoscopy with biopsy To use the sharing features on this page, please enable JavaScript. Mediastinoscopy with biopsy is a procedure in which a lighted instrument ( ...

  14. Sentinel Lymph Node Biopsy

    Science.gov (United States)

    ... Ask about Your Diagnosis Research Sentinel Lymph Node Biopsy On This Page What are lymph nodes? What ... lymph node? What is a sentinel lymph node biopsy? What happens during an SLNB? What are the ...

  15. Nerve biopsy (image)

    Science.gov (United States)

    Nerve biopsy is the removal of a small piece of nerve for examination. Through a small incision, a sample ... is removed and examined under a microscope. Nerve biopsy may be performed to identify nerve degeneration, identify ...

  16. Salivary gland biopsy

    Science.gov (United States)

    ... also be performed to diagnose diseases such as Sjogren syndrome . How to Prepare for the Test There is ... few days after the biopsy. The biopsy for Sjogren syndrome requires an injection of the anesthetic in the ...

  17. Percutaneous liver biopsy.

    Science.gov (United States)

    Rustagi, Tarun; Newton, Eric; Kar, Premashish

    2010-01-01

    Percutaneous liver biopsy has been performed for more than 120 years, and remains an important diagnostic procedure for the management of hepatobiliary disorders. Modern biochemical, immunologic, and radiographic techniques have facilitated the diagnosis and management of liver diseases but have not made liver biopsy obsolete. This comprehensive review article will discuss the history of development of percutaneous liver biopsy, its indications, contraindications, complications and the various aspects of the biopsy procedure in detail.

  18. Characteristics of repeated renal biopsy-proven primary focal segmental glomerulosclerosis in children%重复肾活检为原发性局灶节段性肾小球硬化症患儿临床病理分析

    Institute of Scientific and Technical Information of China (English)

    何瑞娟; 肖慧捷; 刘景城; 王素霞; 杨霁云

    2012-01-01

    目的 对8例经重复肾活检确诊为原发性局灶节段性肾小球硬化症(PFSGS)的患儿进行研究,探讨临床-病理相关性,两次肾活检病理类型的联系以及重复肾活检的指征.方法 回顾分析近10年在北京大学第一医院儿科肾活检的病例,对其中8例重复肾活检、并最终确诊为PFSGS的病例进行分析,总结其临床特点、重复肾活检的指征、前后两次肾活检病理类型的不同,以及治疗反应.其中局灶节段性肾小球硬化症(FSGS)分型依据2004年D'Agati提出的最新分型标准.结果 8例患儿首次发病年龄在1 ~12岁,临床诊断均为肾病综合征.首次肾穿年龄1.1 ~15.0岁,随访时间10个月~14年.重复肾活检的原因为治疗反应差,持续大量蛋白尿不缓解,伴或不伴肾功能下降.3例患儿两次肾活检均在北京大学第一医院完成,第1次病理类型分别为:系膜增生、FSGS细胞型(CELL)及FSGS顶端型(GTL).第2次肾穿后,分别加用或更换免疫抑制剂,3例出现肾功能下降或终末期肾病,起病年龄均在1岁左右;2例FSGS塌陷型(COLL)者,1例重复肾活检发现伴随亚急性小管间质肾炎.结论 PFSGS是一组临床病理综合征,临床表现以肾病综合征多见.在病程中出现治疗反应差,病情持续不缓解时,通常提示病理转型.系膜增生可以转化为FSGS,FSGS各亚型也可发生转换.塌陷型及发病年龄小者预后差.%Objective To analyze the characteristics of repeated renal biopsy-proven primary focal segmental glomerulosclerosis (PFSGS) in 8 children,and to reveal the relationship between clinical features and pathology,between the two times of renal biopsy pathology,and the indications for repeated renal biopsy.Method The records of cases who ever experienced renal biopsy in this hospital were reviewed,of whom 8 cases of repeated renal biopsy-proven PFSGS were enrolled.The clinical manifestations,the reason why they had renal biopsy again

  19. Biopsy (For Parents)

    Science.gov (United States)

    ... Teaching Kids to Be Smart About Social Media Biopsy KidsHealth > For Parents > Biopsy Print A A A What's in this article? ... Questions en español Biopsias What It Is A biopsy is a test that's performed to examine tissue ...

  20. Towards Reversible Sessions

    Directory of Open Access Journals (Sweden)

    Francesco Tiezzi

    2014-06-01

    Full Text Available In this work, we incorporate reversibility into structured communication-based programming, to allow parties of a session to automatically undo, in a rollback fashion, the effect of previously executed interactions. This permits taking different computation paths along the same session, as well as reverting the whole session and starting a new one. Our aim is to define a theoretical basis for examining the interplay in concurrent systems between reversible computation and session-based interaction. We thus enrich a session-based variant of pi-calculus with memory devices, dedicated to keep track of the computation history of sessions in order to reverse it. We discuss our initial investigation concerning the definition of a session type discipline for the proposed reversible calculus, and its practical advantages for static verification of safe composition in communication-centric distributed software performing reversible computations.

  1. Ultrasound-Guided Breast Biopsy

    Science.gov (United States)

    ... Professions Site Index A-Z Ultrasound-Guided Breast Biopsy An ultrasound-guided breast biopsy uses sound waves ... Guided Breast Biopsy? What is Ultrasound-Guided Breast Biopsy? Lumps or abnormalities in the breast are often ...

  2. Stereotactic (Mammographically Guided) Breast Biopsy

    Science.gov (United States)

    ... Resources Professions Site Index A-Z Stereotactic Breast Biopsy Stereotactic breast biopsy uses mammography – a specific type ... Breast Biopsy? What is Stereotactic (Mammographically Guided) Breast Biopsy? Lumps or abnormalities in the breast are often ...

  3. Abdominal wall fat pad biopsy

    Science.gov (United States)

    Amyloidosis - abdominal wall fat pad biopsy; Abdominal wall biopsy; Biopsy - abdominal wall fat pad ... method of taking an abdominal wall fat pad biopsy . The health care provider cleans the skin on ...

  4. Needle Biopsy of the Lung

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Needle Biopsy of the Lung Needle biopsy of the lung ... Needle Biopsy of Lung Nodules? What is Needle Biopsy of the Lung? A lung nodule is relatively ...

  5. Ultrasound-Guided Breast Biopsy

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Ultrasound-Guided Breast Biopsy An ultrasound-guided breast biopsy ... limitations of Ultrasound-Guided Breast Biopsy? What is Ultrasound-Guided Breast Biopsy? Lumps or abnormalities in the ...

  6. Analysis of bone biopsies.

    Science.gov (United States)

    Goodrich, J A; Difiore, R J; Tippens, J K

    1983-11-01

    The orthopedic surgeon is frequently confronted with the decision of when to perform a bone biopsy and whether to do a needle biopsy or an open biopsy. Frequently consultations are received from other services requesting bone biopsies with questionable indications. The indications and contraindications for performing bone biopsies are discussed as well as advantages and disadvantages of either closed or open technique. Four selective cases are discussed with illustrations. The challenge of undiagnosed osseous lesions is best met by rational evaluation of each individual case and coordinated with the team effort of the primary care physician, surgeon, pathologist, and radiologist. The decision for either an open or closed biopsy technique must be based on the experience and skills of the surgeon and pathologist.

  7. Team Exploratory Testing Sessions

    OpenAIRE

    Soili Saukkoriipi; Ilkka Tervonen

    2012-01-01

    Exploratory testing (ET) is popular, especially among agile development teams. In this paper, we study the team aspect in the ET context and explore how to use ET in team sessions to complement other testing activities. The goal was to define a team exploratory testing (TET) session approach and to provide evidence that the approach is worth using. A TET session approach is defined by means of parameters, roles, and process. Also, instructions for using the approach are given. The team is the...

  8. Appropriateness of Liver Biopsy

    OpenAIRE

    Thierry Poynard; Vlad Ratziu; Pierre Bedossa

    2000-01-01

    This review aims to discuss the appropriateness of liver biopsy in two frequent liver diseases, hepatitis C and alcoholic liver disease. The medical literature, published between 1965 and 1999, was reviewed by using MEDLINE. Only 0.1% of the publications were devoted specifically to the appropriateness of liver biopsy. Not all studies observed a significant agreement among doctors on the decision to use liver biopsy. Therefore, there is a possibility that hepatologists have significant, heter...

  9. Changes in the biogenic amine content of the prefrontal cortex, amygdala, dorsal hippocampus, and nucleus accumbens of rats submitted to single and repeated sessions of the elevated plus-maze test

    Directory of Open Access Journals (Sweden)

    Carvalho M.C.

    2005-01-01

    Full Text Available It has been demonstrated that exposure to a variety of stressful experiences enhances fearful reactions when behavior is tested in current animal models of anxiety. Until now, no study has examined the neurochemical changes during the test and retest sessions of rats submitted to the elevated plus maze (EPM. The present study uses a new approach (HPLC by looking at the changes in dopamine and serotonin levels in the prefrontal cortex, amygdala, dorsal hippocampus, and nucleus accumbens in animals upon single or double exposure to the EPM (one-trial tolerance. The study involved two experiments: i saline or midazolam (0.5 mg/kg before the first trial, and ii saline or midazolam before the second trial. For the biochemical analysis a control group injected with saline and not tested in the EPM was included. Stressful stimuli in the EPM were able to elicit one-trial tolerance to midazolam on re-exposure (61.01%. Significant decreases in serotonin contents occurred in the prefrontal cortex (38.74%, amygdala (78.96%, dorsal hippocampus (70.33%, and nucleus accumbens (73.58% of the animals tested in the EPM (P < 0.05 in all cases in relation to controls not exposed to the EPM. A significant decrease in dopamine content was also observed in the amygdala (54.74%, P < 0.05. These changes were maintained across trials. There was no change in the turnover rates of these monoamines. We suggest that exposure to the EPM causes reduced monoaminergic neurotransmission activity in limbic structures, which appears to underlie the "one-trial tolerance" phenomenon.

  10. Open lung biopsy

    Science.gov (United States)

    ... CT scan Disseminated tuberculosis Granulomatosis with polyangiitis Lung cancer - small cell Lung disease Lung needle biopsy Malignant mesothelioma Pulmonary tuberculosis Rheumatoid lung disease Sarcoidosis Simple pulmonary eosinophilia ...

  11. Geometric systematic prostate biopsy.

    Science.gov (United States)

    Chang, Doyoung; Chong, Xue; Kim, Chunwoo; Jun, Changhan; Petrisor, Doru; Han, Misop; Stoianovici, Dan

    2017-04-01

    The common sextant prostate biopsy schema lacks a three-dimensional (3D) geometric definition. The study objective was to determine the influence of the geometric distribution of the cores on the detection probability of prostate cancer (PCa). The detection probability of significant (>0.5 cm(3)) and insignificant (geometric distribution of the cores was optimized to maximize the probability of detecting significant cancer for various prostate sizes (20-100cm(3)), number of biopsy cores (6-40 cores) and biopsy core lengths (14-40 mm) for transrectal and transperineal biopsies. The detection of significant cancer can be improved by geometric optimization. With the current sextant biopsy, up to 20% of tumors may be missed at biopsy in a 20 cm(3) prostate due to the schema. Higher number and longer biopsy cores are required to sample with an equal detection probability in larger prostates. Higher number of cores increases both significant and insignificant tumor detection probability, but predominantly increases the detection of insignificant tumors. The study demonstrates mathematically that the geometric biopsy schema plays an important clinical role, and that increasing the number of biopsy cores is not necessarily helpful.

  12. Transfemoral liver biopsy using a Quick-Core biopsy needle system in living donor liver transplantation recipients.

    Science.gov (United States)

    Li, Fen Qiang; Ko, Gi-Young; Sung, Kyu-Bo; Gwon, Dong-Il; Ko, Heung Kyu; Kim, Jong Woo; Yu, Eunsil

    2014-10-01

    The purpose of this study was to evaluate the efficacy and safety of transfemoral liver biopsy with a Quick-Core biopsy needle in select living donor liver transplantation (LDLT) recipients. Eight LDLT recipients underwent 9 transfemoral liver biopsy sessions. Six patients had undergone modified right lobe (mRL) LDLT, and 2 patients had undergone dual-left lobe LDLT. The indications for transfemoral liver biopsy were a hepatic vein (HV) at an acute angle to the inferior vena cava (IVC) on the coronal plane and a thin (liver parenchyma surrounding the HV to be biopsied on enhanced computed tomography. Under fluoroscopic guidance, the right inferior HV in the mRL or the left HV in the right-sided left lobe with a cranial orientation was negotiated with a 5-Fr catheter via the common femoral vein. Then, a stiffening cannula was introduced into the HV over a stiff guide wire. Needle passage was then performed with an 18- or 19-gauge Quick-Core biopsy needle. Technical success was achieved in all sessions without major complications. The median number of needle passages was 4 (range = 2-6). The median total length of obtained liver specimens in each session was 44 mm (range = 24-75 mm). The median number of portal tracts was 18 (range = 10-29), and the obtained liver specimens were adequate for histological diagnosis in all sessions. In conclusion, transfemoral liver biopsy with a Quick-Core biopsy needle is an effective and safe alternative for obtaining a liver specimen when standard transjugular liver biopsy is not feasible because of an unfavorable HV angle with respect to the IVC and/or a thin liver parenchyma surrounding the HV.

  13. The Public Poster Session

    Science.gov (United States)

    Levine-Rasky, Cynthia

    2009-01-01

    This note describes the use of a student poster session as an innovative approach to student learning. The local context for the assignment is provided, followed by a description of the course for which the poster was prepared, details about the assignment including its evaluation, and practical considerations for planning a poster session. The…

  14. OLYMPICS IN TWO SESSIONS

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    @@ The counting-down clock is ticking:Beijing Olympic Games are just 4 months away.When China's "Two Sessions',the top political sessions,held in the national capital this spring,this heated topic has been inevitably stamped with the remarks among the CPPCC members and NPC deputies.

  15. Lung needle biopsy

    Science.gov (United States)

    ... biopsy Lung tissue biopsy References Ettinger DS. Lung cancer and other pulmonary neoplasms. In: Goldman L, Schafer AI, eds. Goldman's ... 2010:chap 47. Read More Aspiration ... by: Denis Hadjiliadis, MD, Associate Professor of Medicine, Pulmonary, Allergy, and Critical Care, Perelman School of Medicine, ...

  16. Needle biopsy of histoplasmosis

    Energy Technology Data Exchange (ETDEWEB)

    Sinner, W.N.

    1980-12-01

    A case of histoplasmosis, simulating a bronchogenic carcinoma, was needle biopsied. Histoplasma capsulatum organisms were found in great numbers. Needle biopsy established an accurate diagnosis making an exploratory thoracotomy unnecessary and preventing the patient from an already planned lobectomy. Specific treatment with Amphotericin B healed the lesion.

  17. Ureteral retrograde brush biopsy

    Science.gov (United States)

    ... biopsy URL of this page: //medlineplus.gov/ency/article/003906.htm Ureteral retrograde brush biopsy To use ... minutes. A cystoscope is first placed through the urethra into the bladder. Cystoscope is a tube with a ... results may show cancer cells ( carcinoma ). This test is often used to ...

  18. Improved transvenous liver biopsy needle

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Matzen, P; Christoffersen, P

    1979-01-01

    A modified type of the standard transvenous cholangiography biopsy needle is described. The modified tranvenous liver biopsy needle caused only minimal artefactual changes of the liver biopsy specimens. The new type of biopsy needle is a modified Menghini needle. The conventional Menghini needle...... should be avoided for transvenous catheter biopsies because of risk of leaving catheter fragments in the liver....

  19. Biopsy: Types of Biopsy Procedures Used to Diagnose Cancer

    Science.gov (United States)

    ... Cancer You might be nervous about an upcoming biopsy. Learning about biopsies and how and why they're done may ... reduce your anxiety. By Mayo Clinic Staff A biopsy is a procedure to remove a piece of ...

  20. No need for biopsies

    DEFF Research Database (Denmark)

    Gjødsbøl, Kristine; Skindersoe, Mette E; Christensen, Jens Jørgen;

    2011-01-01

    The aim of the study was to compare three sampling techniques used in routine diagnostics to identify the microbiota in chronic venous leg ulcers. A total of 46 patients with persisting venous leg ulcers were included in the study. At inclusion, swab, biopsy and filter paper pad samples were...... collected. After 4 weeks, additional biopsy and filter paper pad samples were collected. Bacteria were isolated and identified at species level by standard methods. The most common bacterial species detected was Staphylococcus aureus found in 89% of the ulcers. No methicillin-resistant S. aureus isolates...... species present in chronic wounds, thus avoiding complications during and after biopsy sampling....

  1. Abstracts of SIG Sessions.

    Science.gov (United States)

    Proceedings of the ASIS Annual Meeting, 1997

    1997-01-01

    Presents abstracts of SIG Sessions. Highlights include digital collections; information retrieval methods; public interest/fair use; classification and indexing; electronic publication; funding; globalization; information technology projects; interface design; networking in developing countries; metadata; multilingual databases; networked…

  2. Wilson disease:Histopathological correlations with treatment on follow-up liver biopsies

    Institute of Scientific and Technical Information of China (English)

    Sandy; Cope-Yokoyama; Milton; J; Finegold; Giacomo; Carlo; Sturniolo; Kyoungmi; Kim; Claudia; Mescoli; Massimo; Rugge; Valentina; Medici

    2010-01-01

    AIM:To investigate the progression of hepatic histopathology in serial liver biopsies from Wilson disease(WD)patients.METHODS:We report a group of 12 WD patients treated with zinc and/or penicillamine who underwent multiple follow-up liver biopsies.Demographic,clinical and laboratory data were gathered and all patients underwent an initial biopsy and at least one repeat biopsy.RESULTS:Time to repeat biopsy ranged from 2 to 12 years.Six patients(non-progressors)showed stable hepatic histology or improvement....

  3. Colposcopy - directed biopsy

    Science.gov (United States)

    ... squamous cells - colposcopy; Pap smear - colposcopy; HPV - colposcopy; Human papilloma virus - colposcopy; Cervix - colposcopy; Colposcopy ... also called cervical dysplasia) Cervical warts (infection with human papilloma virus , or HPV) If the biopsy does not ...

  4. Oropharynx lesion biopsy

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003850.htm Oropharynx lesion biopsy To use the sharing features on this ... Department of Otolaryngology - Head and Neck Surgery, The University of Texas Medical School at Houston, Houston, TX. ...

  5. Renal Tumor Biopsy Technique

    Institute of Scientific and Technical Information of China (English)

    Lei Zhang; Xue-Song Li; Li-Qun Zhou

    2016-01-01

    Objective:To review hot issues and future direction of renal tumor biopsy (RTB) technique.Data Sources:The literature concerning or including RTB technique in English was collected from PubMed published from 1990 to 2015.Study Selection:We included all the relevant articles on RTB technique in English,with no limitation of study design.Results:Computed tomography and ultrasound were usually used for guiding RTB with respective advantages.Core biopsy is more preferred over fine needle aspiration because of superior accuracy.A minimum of two good-quality cores for a single renal tumor is generally accepted.The use of coaxial guide is recommended.For biopsy location,sampling different regions including central and peripheral biopsies are recommended.Conclusion:In spite of some limitations,RTB technique is relatively mature to help optimize the treatment of renal tumors.

  6. Where Do TRUS- and MRI Guided Biopsies Miss Significant Prostate Cancer?

    DEFF Research Database (Denmark)

    Boesen, Lars; Nørgaard, Nis; Løgager, Vibeke

    2017-01-01

    OBJECTIVE: To identify the location of missed sPCa lesions by transrectal ultrasound-guided (TRUSbx) and multiparametric MRI-guided biopsies (mpMRIbx) in men undergoing repeat biopsies. METHODS: 289 men with prior negative TRUSbx underwent mpMRI. The location of any suspicious lesion was registered...... and scored using PIRADS v1 classification according to the likelihood of being sPCa. All patients underwent repeat (re-)TRUSbx and targeted mpMRIbx (image fusion) of any suspicious lesion. Biopsy results were compared and the location of missed sPCa lesions were registered. Cancer significance was defined as...... techniques in men undergoing repeat biopsies....

  7. Corpus vitreum, retina og chorioidea biopsi

    DEFF Research Database (Denmark)

    Scherfig, Erik Christian Høegh

    2002-01-01

    oftalmology, biopsy, choroid, corpus vitreum, retina, malignant melanoma, biopsy technic, retinoblastoma......oftalmology, biopsy, choroid, corpus vitreum, retina, malignant melanoma, biopsy technic, retinoblastoma...

  8. The Terry Biopsy Needle

    Science.gov (United States)

    Bond, Alan F.; Murphy, Fergus A.; Nanson, Eric M.

    1963-01-01

    Six illustrative cases are reported to demonstrate the versatility of the Terry biopsy needle as a useful instrument for obtaining satisfactory biopsy specimens from the liver and from other tissues as well. The apparatus and method of use are described and illustrated. ImagesFig. 1Fig. 2Fig. 3Fig. 4Fig. 5Fig. 6aFig. 6bFig. 7Fig. 8Fig. 9Fig. 10Fig. 11 PMID:13968726

  9. Biopsy in Musculoskeletal Tumors

    Directory of Open Access Journals (Sweden)

    Mohammad Gharehdaghi

    2014-09-01

    Full Text Available Diagnosis of bone tumors is based on careful evaluation of clinical, imaging and a pathologic findings. So the biopsy of bone and soft tissue sarcomas is the final step in evaluation and a fundamental step in the diagnosis of the lesion. It should not be performed as a shortcut to diagnosis (1. The biopsy should be performed in order to confirm the diagnosis and differentiate among few diagnoses after careful staged studies. Real and artificial changes in imaging studies will be superimposed after performing biopsy, which may alter the interpretation if done after biopsy is taken (1. The correct management of a sarcoma depends on the accurate diagnosis. Inadequate, inapprppriate, or inaccurate non-representative biopsy leads to poorer outcome in terms of survivorship and limb salvage. An incorrect, unplanned incision and biopsy may unnecessarily contaminate uninvolved compartments which may convert a salvageable limb to amputation. Anatomic approach along with the proper biopsy techniques may lead to success or catastrophe. It is clear that in patients with inappropriate biopsy, the chance of the need to change the treatment to more radical than would originally be expected is significantly higher. Also it is more probable to need to  convert curative to palliative treatment and to require adjuvant radiotherapy in patients with inappropriate biopsies. Patients with sarcoma are best served by early referral to a specialized center where staged investigations and biopsy can be performed with minimal morbidity (3. Open biopsy is still considered the gold standard; however, recent studies suggest comparable results with percutaneous core needle biopsy. Our study on 103 consecutive CNB and open biopsy showed comparable results as well. Surgeons need to answer to two questions prior to performing a biopsy: 1-          Where is the best part of the lesion to be biopsied? 2-          What is the safest route without contaminating

  10. Percutaneous CT-guided needle biopsies of musculoskeletal tumors: a 5-year analysis of non-diagnostic biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Connie Y.; Huang, Ambrose J.; Bredella, Miriam A.; Torriani, Martin; Rosenthal, Daniel I. [Massachusetts General Hospital, Division of Musculoskeletal Imaging and Intervention, Department of Radiology, Boston, MA (United States); Halpern, Elkan F. [Massachusetts General Hospital, Institute for Technology Assessment, Department of Radiology, Boston, MA (United States); Springfield, Dempsey S. [Massachusetts General Hospital, Department of Orthopedics, Boston, MA (United States)

    2015-12-15

    To study non-diagnostic CT-guided musculoskeletal biopsies and take steps to minimize them. Specifically we asked: (1) What malignant diagnoses have a higher non-diagnostic rate? (2) What factors of a non-diagnostic biopsy may warrant more aggressive pursuit? (3) Do intra-procedural frozen pathology (FP) or point-of-care (POC) cytology reduce the non-diagnostic biopsy rate ?This study was IRB-approved and HIPAA-compliant. We retrospectively reviewed 963 consecutive CT-guided musculoskeletal biopsies. We categorized pathology results as malignant, benign, or non-diagnostic and recorded use of FP or POC cytology. Initial biopsy indication, final diagnosis, method of obtaining the final diagnosis of non-diagnostic biopsies, age of the patient, and years of biopsy attending experience were recorded. Groups were compared using Pearson's χ{sup 2} test or Fisher's exact test. In all, 140 of 963 (15 %) biopsies were non-diagnostic. Lymphoma resulted in more non-diagnostic biopsies (P < 0.0001). While 67% of non-diagnostic biopsies yielded benign diagnoses, 33% yielded malignant diagnoses. Patients whose percutaneous biopsy was indicated due to the clinical context without malignancy history almost always generated benign results (96 %). Whereas 56% of biopsies whose indication was an imaging finding of a treatable lesion were malignant, 20% of biopsies whose indication was a history of malignancy were malignant. There was no statistically significant difference in the nondiagnostic biopsy rates of pediatric versus adult patients (P = 0.8) and of biopsy attendings with fewer versus more years of experience (P = 0.5). The non-diagnostic rates of biopsies with FP (8 %), POC cytology (25 %), or neither (24 %) were significantly different (P < 0.0001). Lymphoma is the malignant diagnosis most likely to result in a non-diagnostic biopsy. If the clinical and radiologic suspicion for malignancy is high, repeat biopsy is warranted. If the clinical context suggests a

  11. Midazolam sedation for percutaneous liver biopsy.

    Science.gov (United States)

    Alexander, J A; Smith, B J

    1993-12-01

    Control of patient respiration is needed to safely perform percutaneous liver biopsy (PLB) and may be adversely affected by sedation. The purpose of this study was to evaluate the safety of PLB with intravenous midazolam and to evaluate patient acceptance of PLB with and without sedation. Two hundred seventeen consecutive patients underwent 301 percutaneous liver biopsies. One hundred fifty-one of the biopsies were done after the patients were sedated with intravenous midazolam immediately before the biopsy. The last 61 patients were questioned after the biopsy to evaluate the discomfort of the procedure, their memory of the procedure, and their willingness to undergo another PLB. The major complication rate was similar in the midazolam-treated (0.7%) and untreated (0.7%) groups. The midazolam-treated patients had a numerically lower mean pain score (1.5 +/- 0.4 vs 4.0 +/- 0.7) (mean +/- SEM) (P = 0.07) and significantly lower mean memory score (4.8 +/- 0.7 vs 9.9 +/- 0.1) (P < 0.01) than the untreated patients. The treated and untreated groups had similar mean willingness for repeat PLB scores (9.3 +/- 0.3 vs 9.1 +/- 0.6). We conclude that: (1) there is no increased risk of PLB with midazolam and (2) patients have less memory of the procedure with midazolam.

  12. Punch Biopsy Results of Nasopharynx Pathologies

    Directory of Open Access Journals (Sweden)

    İsa Özbay

    2016-03-01

    Full Text Available Objective: Although nasopharynx (NF has an anatomi­cally distant sites to view, biopsy can be taken easily from NF by the help of an endoscope in order to reach a defini­tive diagnosis. In this study, NF pathology results in the patient group were analyzed retrospectively. Methods: NF biopsy results of 80 patients who were ad­mitted to Ear, Nose and Throat (ENT clinic of Dumlupınar University Evliya Celebi Education and Research Hospital between September 2012-February 2016 were included in the study, retrospectively. NF has been viewed to rule out NF cancer under general or local anesthesia by rigid or flexible endoscopes and punch biopsies were taken. Results: NF patients who underwent biopsy were com­posed of 25 (31.2% females and 55 (68.8% males and the average age was 35.33. Histopathological results in 3 patients (3.7% were malignant. The pathology (96.3% were identified as chronic lymphoid hyperplasia and lym­phoid processes in the remaining 77 patients. 4 patients underwent repeat biopsy follow-on clinical suspicion of malignancy, but ultimately malignancy was not observed. Conclusion: NF biopsy is a method which is easily ap­plied in the examination of the cancer and other masses of NF. In this study, age, sex, clinical and histopathologic analysis of the patients who underwent NF biopsies were discussed in the light of the literature. J Clin Exp Invest 2016; 7 (1: 83-86

  13. Computational optical biopsy

    Directory of Open Access Journals (Sweden)

    Jiang Ming

    2005-06-01

    Full Text Available Abstract Optical molecular imaging is based on fluorescence or bioluminescence, and hindered by photon scattering in the tissue, especially in patient studies. Here we propose a computational optical biopsy (COB approach to localize and quantify a light source deep inside a subject. In contrast to existing optical biopsy techniques, our scheme is to collect optical signals directly from a region of interest along one or multiple biopsy paths in a subject, and then compute features of an underlying light source distribution. In this paper, we formulate this inverse problem in the framework of diffusion approximation, demonstrate the solution uniqueness properties in two representative configurations, and obtain analytic solutions for reconstruction of both optical properties and source parameters.

  14. Breast Biopsy System

    Science.gov (United States)

    1994-01-01

    Charge Coupled Devices (CCDs) are high technology silicon chips that connect light directly into electronic or digital images, which can be manipulated or enhanced by computers. When Goddard Space Flight Center (GSFC) scientists realized that existing CCD technology could not meet scientific requirements for the Hubble Space Telescope Imagining Spectrograph, GSFC contracted with Scientific Imaging Technologies, Inc. (SITe) to develop an advanced CCD. SITe then applied many of the NASA-driven enhancements to the manufacture of CCDs for digital mammography. The resulting device images breast tissue more clearly and efficiently. The LORAD Stereo Guide Breast Biopsy system incorporates SITe's CCD as part of a digital camera system that is replacing surgical biopsy in many cases. Known as stereotactic needle biopsy, it is performed under local anesthesia with a needle and saves women time, pain, scarring, radiation exposure and money.

  15. PERCUTANEOUS PLEURAL BIOPSY

    Directory of Open Access Journals (Sweden)

    M. Bahadori

    1966-01-01

    Full Text Available I have carried out 22 biopsies in 20 Patients, in fifteen I used a Vim _ Silverman Needle, and in the remainder a curetting type Needle, In 12 cases (60% the diagnosis that was made; in 3 cases, inadequate tissue, was obtained; in two cases a fibromuscular tissue, in one case a fatty tissue and in one case the specimen was of hepatic tissue. Even with the small biopsy specimen obtained with the Needle it is easy to recognize malignant tissue if present.

  16. Multiparty Asynchronous Session Types

    DEFF Research Database (Denmark)

    Honda, Kohei; Yoshida, Nobuko; Carbone, Marco

    2016-01-01

    peers are directly abstracted as a global scenario. Global types retain the friendly type syntax of binary session types while specifying dependencies and capturing complex causal chains of multiparty asynchronous interactions. A global type plays the role of a shared agreement among communication peers...

  17. Abstracts of SIG Sessions.

    Science.gov (United States)

    Proceedings of the ASIS Annual Meeting, 1995

    1995-01-01

    Presents abstracts of 15 special interest group (SIG) sessions. Topics include navigation and information utilization in the Internet, natural language processing, automatic indexing, image indexing, classification, users' models of database searching, online public access catalogs, education for information professions, information services,…

  18. The outreach sessions

    Energy Technology Data Exchange (ETDEWEB)

    Trache, Livius [Horia Hulubei National Institute for Physics and Nuclear Engineering, P.O. Box MG-6, 077125 Bucharest-Magurele (Romania)

    2015-02-24

    These are moderator’s remarks about the outreach day in the middle of the CSSP14, and in particular about the afternoon outreach session in round table format with the announced theme: “CERN at 60 and the internationalization of science”.

  19. Ultrasound- and MRI-Guided Prostate Biopsy

    Science.gov (United States)

    ... Index A-Z Ultrasound- and MRI-Guided Prostate Biopsy Ultrasound- and MRI-guided prostate biopsy uses imaging ... Biopsy? What is Ultrasound- and MRI-guided Prostate Biopsy? Ultrasound- and MRI-guided prostate biopsies are performed ...

  20. Is liver biopsy mandatory in children with chronic hepatitis C?

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Liver biopsy is considered the most accurate means to estimate the necroinflammatory activity and the extent of fibrosis. However, histology evaluation is an invasive procedure associated with risk to the patient, risk of sampling error and diagnostic inconsistencies due to inter- and intra-observer error. On the basis of histological studies performed so far, chronic hepatitis C in children appears morphologically benign in the majority of cases.At the Pediatric Liver Unit of our university, a total of 67 children with chronic hep, atitis C underwent liver biopsy.Liver biopsy was repeated 5.5 years after the initial histological evaluation in 21 children. On a total number of 88 liver biopsies, micronodular cirrhosis was detected only in one genotype 1b-infected obese child. Since liver histology investigation of a child with chronic hepatitis C has few chances to highlight severe lesions, we question how liver biopsy helps in the management of children with chronic hepatitis C.

  1. Percutaneous renal tumour biopsy.

    Science.gov (United States)

    Delahunt, Brett; Samaratunga, Hemamali; Martignoni, Guido; Srigley, John R; Evans, Andrew J; Brunelli, Matteo

    2014-09-01

    The use of percutaneous renal tumour biopsy (RTB) as a diagnostic tool for the histological characterization of renal masses has increased dramatically within the last 30 years. This increased utilization has paralleled advances in imaging techniques and an evolving knowledge of the clinical value of nephron sparing surgery. Improved biopsy techniques using image guidance, coupled with the use of smaller gauge needles has led to a decrease in complication rates. Reports from series containing a large number of cases have shown the non-diagnostic rate of RTB to range from 4% to 21%. Re-biopsy has been shown to reduce this rate, while the use of molecular markers further improves diagnostic sensitivity. In parallel with refinements of the biopsy procedure, there has been a rapid expansion in our understanding of the complexity of renal cell neoplasia. The 2013 Vancouver Classification is the current classification for renal tumours, and contains five additional entities recognized as novel forms of renal malignancy. The diagnosis of tumour morphotype on RTB is usually achievable on routine histology; however, immunohistochemical studies may be of assistance in difficult cases. The morphology of the main tumour subtypes, based upon the Vancouver Classification, is described and differentiating features are discussed.

  2. Magnetic resonance imaging-targeted, 3D transrectal ultrasound-guided fusion biopsy for prostate cancer: Quantifying the impact of needle delivery error on diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Peter R., E-mail: pmarti46@uwo.ca [Department of Medical Biophysics, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Cool, Derek W. [Department of Medical Imaging, The University of Western Ontario, London, Ontario N6A 3K7, Canada and Robarts Research Institute, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Romagnoli, Cesare [Department of Medical Imaging, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Fenster, Aaron [Department of Medical Biophysics, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Department of Medical Imaging, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Robarts Research Institute, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Ward, Aaron D. [Department of Medical Biophysics, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Department of Oncology, The University of Western Ontario, London, Ontario N6A 3K7 (Canada)

    2014-07-15

    Purpose: Magnetic resonance imaging (MRI)-targeted, 3D transrectal ultrasound (TRUS)-guided “fusion” prostate biopsy intends to reduce the ∼23% false negative rate of clinical two-dimensional TRUS-guided sextant biopsy. Although it has been reported to double the positive yield, MRI-targeted biopsies continue to yield false negatives. Therefore, the authors propose to investigate how biopsy system needle delivery error affects the probability of sampling each tumor, by accounting for uncertainties due to guidance system error, image registration error, and irregular tumor shapes. Methods: T2-weighted, dynamic contrast-enhanced T1-weighted, and diffusion-weighted prostate MRI and 3D TRUS images were obtained from 49 patients. A radiologist and radiology resident contoured 81 suspicious regions, yielding 3D tumor surfaces that were registered to the 3D TRUS images using an iterative closest point prostate surface-based method to yield 3D binary images of the suspicious regions in the TRUS context. The probabilityP of obtaining a sample of tumor tissue in one biopsy core was calculated by integrating a 3D Gaussian distribution over each suspicious region domain. Next, the authors performed an exhaustive search to determine the maximum root mean squared error (RMSE, in mm) of a biopsy system that gives P ≥ 95% for each tumor sample, and then repeated this procedure for equal-volume spheres corresponding to each tumor sample. Finally, the authors investigated the effect of probe-axis-direction error on measured tumor burden by studying the relationship between the error and estimated percentage of core involvement. Results: Given a 3.5 mm RMSE for contemporary fusion biopsy systems,P ≥ 95% for 21 out of 81 tumors. The authors determined that for a biopsy system with 3.5 mm RMSE, one cannot expect to sample tumors of approximately 1 cm{sup 3} or smaller with 95% probability with only one biopsy core. The predicted maximum RMSE giving P ≥ 95% for each

  3. Bone Marrow Aspiration and Biopsy

    Science.gov (United States)

    ... Advertising & Sponsorship: Policy | Opportunities Bone Marrow Aspiration and Biopsy Share this page: Was this page helpful? Also ... Examination Formal name: Bone Marrow Aspiration; Bone Marrow Biopsy Related tests: Complete Blood Count ; WBC Differential ; Reticulocyte ...

  4. No need for biopsies

    DEFF Research Database (Denmark)

    Gjødsbøl, Kristine; Skindersoe, Mette E; Christensen, Jens Jørgen;

    2011-01-01

    The aim of the study was to compare three sampling techniques used in routine diagnostics to identify the microbiota in chronic venous leg ulcers. A total of 46 patients with persisting venous leg ulcers were included in the study. At inclusion, swab, biopsy and filter paper pad samples were...... collected. After 4 weeks, additional biopsy and filter paper pad samples were collected. Bacteria were isolated and identified at species level by standard methods. The most common bacterial species detected was Staphylococcus aureus found in 89% of the ulcers. No methicillin-resistant S. aureus isolates...... were found. We did not find any significant differences regarding the bacterial species isolated between the three sampling techniques. However, using multiple techniques led to identification of more species. Our study suggests that it is sufficient to use swab specimens to identify the bacterial...

  5. Deployment Repeatability

    Science.gov (United States)

    2016-04-01

    controlled to great precision, but in a Cubesat , there may be no attitude determination at all. Such a Cubesat might treat sun angle and tumbling rates as...could be sensitive to small differences in motor controller timing. In these cases, the analyst might choose to model the entire deployment path, with...knowledge of the material damage model or motor controller timing precision. On the other hand, if many repeated and environmentally representative

  6. Complications in Transbronchial Lung Biopsy

    OpenAIRE

    Hue, Sung Ho

    1987-01-01

    Transbronchial lung biopsy was performed in 68 patients with various lung diseases. As an inital diagnostic procedure in diffuse and localized lung diseases, trasbronchial lung biopsy offers an attractive alternative to open lung biopsy. Recently imporvement in the development of medical technology has greatly facilitated this technique, but it must be kept in mind that a transbronchial lung biopsy is not without complication and sometimes potentially serious complications may occur. This stu...

  7. Muscle biopsies off-set normal cellular signaling in surrounding musculature

    DEFF Research Database (Denmark)

    Krag, Thomas O; Hauerslev, Simon; Dahlqvist, Julia R

    2013-01-01

    muscle tissue for at least 3 weeks after the biopsy was performed and magnetic resonance imaging suggests that an effect of a biopsy may persist for at least 5 months. Cellular signaling after a biopsy resembles what is seen in severe limb-girdle muscular dystrophy type 2I with respect to protein......Studies of muscle physiology and muscular disorders often require muscle biopsies to answer questions about muscle biology. In this context, we have often wondered if muscle biopsies, especially if performed repeatedly, would affect interpretation of muscle morphology and cellular signaling. We...... hypothesized that muscle morphology and cellular signaling involved in myogenesis/regeneration and protein turnover can be changed by a previous muscle biopsy in close proximity to the area under investigation. Here we report a case where a past biopsy or biopsies affect cellular signaling of the surrounding...

  8. Immunoglobulin deposits in peripheral nerve endings detected by skin biopsy in patients with IgM M proteins and neuropathy

    DEFF Research Database (Denmark)

    Jønsson, V; Jensen, T S; Friis, M L;

    1987-01-01

    biopsies provide a simple effective method of detecting immunoglobulin binding to peripheral nerves in patients suspected of having an autoimmune neuropathy. In contrast to sural nerve biopsy, skin biopsy does not cause sensory loss or pain in a denervated area and can easily be repeated....

  9. Optimization of Prostate Biopsy: the Role of Magnetic Resonance Imaging Targeted Biopsy in Detection, Localization and Risk Assessment

    Science.gov (United States)

    Bjurlin, Marc A.; Meng, Xiaosong; Le Nobin, Julien; Wysock, James S.; Lepor, Herbert; Rosenkrantz, Andrew B.; Taneja, Samir S.

    2014-01-01

    Purpose Optimization of prostate biopsy requires addressing the shortcomings of standard systematic transrectal ultrasound guided biopsy, including false-negative rates, incorrect risk stratification, detection of clinically insignificant disease and the need for repeat biopsy. Magnetic resonance imaging is an evolving noninvasive imaging modality that increases the accurate localization of prostate cancer at the time of biopsy, and thereby enhances clinical risk assessment and improves the ability to appropriately counsel patients regarding therapy. In this review we 1) summarize the various sequences that comprise a prostate multiparametric magnetic resonance imaging examination along with its performance characteristics in cancer detection, localization and reporting standards; 2) evaluate potential applications of magnetic resonance imaging targeting in prostate biopsy among men with no previous biopsy, a negative previous biopsy and those with low stage cancer; and 3) describe the techniques of magnetic resonance imaging targeted biopsy and comparative study outcomes. Materials and Methods A bibliographic search covering the period up to October 2013 was conducted using MEDLINE®/PubMed®. Articles were reviewed and categorized based on which of the 3 objectives of this review was addressed. Data were extracted, analyzed and summarized. Results Multiparametric magnetic resonance imaging consists of anatomical T2-weighted imaging coupled with at least 2 functional imaging techniques. It has demonstrated improved prostate cancer detection sensitivity up to 80% in the peripheral zone and 81% in the transition zone. A prostate cancer magnetic resonance imaging suspicion score has been developed, and is depicted using the Likert or PI-RADS (Prostate Imaging Reporting and Data System) scale for better standardization of magnetic resonance imaging interpretation and reporting. Among men with no previous biopsy, magnetic resonance imaging increases the frequency of

  10. Synchrony in Dyadic Psychotherapy Sessions

    Science.gov (United States)

    Ramseyer, Fabian; Tschacher, Wolfgang

    Synchrony is a multi-faceted concept used in diverse domains such as physics, biology, and the social sciences. This chapter reviews some of the evidence of nonverbal synchrony in human communication, with a main focus on the role of synchrony in the psychotherapeutic setting. Nonverbal synchrony describes coordinated behavior of patient and therapist. Its association with empathy, rapport and the therapeutic relationship has been pointed out repeatedly, yet close evaluation of empirical studies suggests that the evidence remains inconclusive. Particularly in naturalistic studies, research with quantitative measures of synchrony is still lacking. We introduce a new empirical approach for the study of synchrony in psychotherapies under field conditions: Motion Energy Analysis (MEA). This is a video-based algorithm that quantifies the amount of movement in freely definable regions of interest. Our statistical analysis detects synchrony on a global level, irrespective of the specific body parts moving. Synchrony thus defined can be considered as a general measure of movement coordination between interacting individuals. Data from a sequence of N = 21 therapy sessions taken from one psychotherapy dyad shows a high positive relationship between synchrony and the therapeutic bond. Nonverbal synchrony can thus be considered a promising concept for research on the therapeutic alliance. Further areas of application are discussed.

  11. Session: Hard Rock Penetration

    Energy Technology Data Exchange (ETDEWEB)

    Tennyson, George P. Jr.; Dunn, James C.; Drumheller, Douglas S.; Glowka, David A.; Lysne, Peter

    1992-01-01

    This session at the Geothermal Energy Program Review X: Geothermal Energy and the Utility Market consisted of five presentations: ''Hard Rock Penetration - Summary'' by George P. Tennyson, Jr.; ''Overview - Hard Rock Penetration'' by James C. Dunn; ''An Overview of Acoustic Telemetry'' by Douglas S. Drumheller; ''Lost Circulation Technology Development Status'' by David A. Glowka; ''Downhole Memory-Logging Tools'' by Peter Lysne.

  12. Session: Reservoir Technology

    Energy Technology Data Exchange (ETDEWEB)

    Renner, Joel L.; Bodvarsson, Gudmundur S.; Wannamaker, Philip E.; Horne, Roland N.; Shook, G. Michael

    1992-01-01

    This session at the Geothermal Energy Program Review X: Geothermal Energy and the Utility Market consisted of five papers: ''Reservoir Technology'' by Joel L. Renner; ''LBL Research on the Geysers: Conceptual Models, Simulation and Monitoring Studies'' by Gudmundur S. Bodvarsson; ''Geothermal Geophysical Research in Electrical Methods at UURI'' by Philip E. Wannamaker; ''Optimizing Reinjection Strategy at Palinpinon, Philippines Based on Chloride Data'' by Roland N. Horne; ''TETRAD Reservoir Simulation'' by G. Michael Shook

  13. ICALEPS 2005 : opening session

    CERN Multimedia

    Maximilien Brice

    2005-01-01

    ICALEPCS 2005, the tenth International Conference on Accelerator and Large Experimental Physics Control Systems, will be held in Geneva, Switzerland, 10-14 Oct. 2005 at the International Conference Center Geneva (CICG). ICALEPCS 2005 thus falls in the year that UNESCO has declared the "World Year of Physics". ICALEPCS covers all aspects of control and operation of Experimental Physics facilities such as particle accelerators, particle detectors, optical telescopes, radio telescopes, nuclear fusion facilities like Tokamaks, nuclear reactors, lasers, etc .... Opening session by . A. Daneels (CERN): Introducting ICALEPCS 2005 . C.Lamprecht (Republic & State of Geneva): Welcome speech . J. Lister (EPFL): Welcome speech . J. Engelen (CERN): The machine and experiment challenges of LHC

  14. Ultrasound-guided renal biopsy with automated biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Pil Yeob; Kwon, Jae Soo [Masan Samsung Hospital, Masan (Korea, Republic of)

    1998-01-01

    To elevate the diagnostic yield and complications of percutaneous ultrasound-guided renal biopsy using a biopsy gun in patients with diffuse renal disease. Using an automated biopsy gun mounted with a 16 G needle, biopsies were performed on 90 patients with diffuse renal disease. In a total of 95 biopsies, diagnostic yield, the mean number of glomeruli and frequency of complication were retrospectively analysed. Tissue adequate for histological diagnosis was obtained in 92 % of procedures. Mean glomerular yield was 8.3, and complications were seen in 26% of the procedures, 25 % of these were minor, and 1% were major. For the diagnosis of diffuse renal disease, ultrasound-guided percutaneous renal biopsy using an automated biopsy gun is accurate and safe. (author). 25 refs., 1 tab.

  15. Value of Targeted Prostate Biopsy Using Magnetic Resonance–Ultrasound Fusion in Men with Prior Negative Biopsy and Elevated Prostate-specific Antigen

    Science.gov (United States)

    Sonn, Geoffrey A.; Chang, Edward; Natarajan, Shyam; Margolis, Daniel J.; Macairan, Malu; Lieu, Patricia; Huang, Jiaoti; Dorey, Frederick J.; Reiter, Robert E.; Marks, Leonard S.

    2013-01-01

    Background Conventional biopsy fails to detect the presence of some prostate cancers (PCas). Men with a prior negative biopsy but persistently elevated prostate-specific antigen (PSA) pose a diagnostic dilemma, as some harbor elusive cancer. Objective To determine whether use of magnetic resonance–ultrasound (MR-US) fusion biopsy results in improved detection of PCa compared to repeat conventional biopsy. Design, setting, and participants In a consecutive-case series, 105 subjects with prior negative biopsy and elevated PSA values underwent multiparametric magnetic resonance imaging (MRI) and fusion biopsy in an outpatient setting. Intervention Suspicious areas on multiparametric MRI were delineated and graded by a radiologist; MR–US fusion biopsy was performed by a urologist using the Artemis device; targeted and systematic biopsies were obtained regardless of MRI result. Outcome measurements and statistical analysis Detection rates of all PCa and clinically significant PCa (Gleason ≥3 + 4 or Gleason 6 with maximal cancer core length ≥4 mm) were determined. The yield of targeted biopsy was compared to systematic biopsy. The ability of an MRI grading system to predict clinically significant cancer was investigated. Stepwise multivariate logistic regression analysis was performed to determine predictors of significant cancer on biopsy. Results and limitations Fusion biopsy revealed PCa in 36 of 105 men (34%; 95% confidence interval [CI], 25–45). Seventy-two percent of men with PCa had clinically significant disease; 21 of 23 men (91%) with PCa on targeted biopsy had significant cancer compared to 15 of 28 (54%) with systematic biopsy. Degree of suspicion on MRI was the most powerful predictor of significant cancer on multivariate analysis. Twelve of 14 (86%) subjects with a highly suspicious MRI target were diagnosed with clinically significant cancer. Conclusions MR-US fusion biopsy provides improved detection of PCa in men with prior negative biopsies

  16. Different Methods for Prostate Biopsy and Biopsy Protocols

    Directory of Open Access Journals (Sweden)

    Mahyar Ghafoori

    2011-05-01

    Full Text Available Prostate carcinoma is one of the most common"nmalignancies among men. Increasing mortality rates due"nto prostate carcinoma have been observed worldwide."nThis disease usually progresses imperceptibly, for this"nreason; screening programs aimed at early detection"nhave been developed. The prostate specific antigen"n(PSA test is among the best screening tools available"nin medicine today because it is recognized as the best"nmarker for its early detection."nIn case of abnormal rise in PSA, the patient usually"nrefers for prostate biopsy under the guide of trans"nrectal ultrasonography (TRUS. Different methods are"nrecognized for prostate biopsy that may be divided"ninto two main categories namely, systematic biopsy"nand targeted biopsy."nIn systematic biopsy we divide the prostate gland"nrandomly to different sections and obtain biopsy"nspecimens from each section.The protocol of systematic biopsy is different among"ndifferent institutions. The number of biopsy specimens"ncould be started from less than 6 to more than 20"nbiopsies in some institutions. Increasing the number"nof biopsy specimens increases the detection rate for"nprostate cancer increasing the complications such"nas post biopsy prostatitis and septicemia, which are"nthe most important, as well. In scheduling a biopsy"nprotocol with high number of biopsies it is preferred"nto hospitalize the patient and prescribe intravenous"nantibiotics."nTargeted biopsy of the prostate means obtaining biopsy"nspecimens from a pathologic lesion that is suspicious"nfor prostate cancer. Different modalities could be"nused for detecting prostate cancer within the prostate"ngland. Transrectal ultrasonography, ultrasonography"nwith the use of ultrasound contrast agents, MRI of the"nprostate with the use of endorectal coil, dynamic MR"nstudy with contrast agent, diffusion weighted imaging"nof the prostate and MR spectroscopy all could help"nin the detection of a suspicious tumoral mass in the

  17. The accuracy of colposcopic biopsy

    DEFF Research Database (Denmark)

    Stoler, Mark H; Vichnin, Michelle D; Ferenczy, Alex;

    2011-01-01

    We evaluated the overall agreement between colposcopically directed biopsies and the definitive excisional specimens within the context of three clinical trials. A total of 737 women aged 16-45 who had a cervical biopsy taken within 6 months before their definitive therapy were included. Per......-protocol, colposcopists were to also obtain a representative cervical biopsy immediately before definitive therapy. Using adjudicated histological diagnoses, the initial biopsies and the same day biopsies were correlated with the surgically excised specimens. The overall agreement between the biopsies taken within 6...... degree of variance in the correlation, the overall agreement was 92% for CIN2-3/AIS. The overall agreement between the same day biopsy and definitive therapy specimen was 56% (weighted kappa = 0.41) (95% CI: 0.36-0.47), and the underestimation of CIN2-3/AIS was 57%. There were significant associations...

  18. Beyond Diagnosis: Evolving Prostate Biopsy in the Era of Focal Therapy

    Directory of Open Access Journals (Sweden)

    J. L. Dominguez-Escrig

    2011-01-01

    Full Text Available Despite decades of use as the “gold standard” in the detection of prostate cancer, the optimal biopsy regimen is still not universally agreed upon. While important aspects such as the need for laterally placed biopsies and the importance of apical cancer are known, repeated studies have shown significant patients with cancer on subsequent biopsy when the original biopsy was negative and an ongoing suspicion of cancer remained. Attempts to maximise the effectiveness of repeat biopsies have given rise to the alternate approaches of saturation biopsy and the transperineal approach. Recent interest in focal treatment of prostate cancer has further highlighted the need for accurate detection of prostate cancer, and in response, the introduction of transperineal template-guided biopsy. While the saturation biopsy approach and the transperineal template approach increase the detection rate of cancer in men with a previous negative biopsy and appear to have acceptable morbidity, there is a lack of clinical trials evaluating the different biopsy strategies. This paper reviews the evolution of prostatic biopsy and current controversies.

  19. For Women Facing a Breast Biopsy

    Science.gov (United States)

    ... Cancer Breast Cancer Early Detection and Diagnosis Breast Biopsy When other tests show that you might have ... before getting a breast biopsy. Fine needle aspiration biopsy In a fine needle aspiration (FNA) biopsy , a ...

  20. Orchestrated Session Compliance

    Directory of Open Access Journals (Sweden)

    Franco Barbanera

    2015-08-01

    Full Text Available We investigate the notion of orchestrated compliance for client/server interactions in the context of session contracts. Devising the notion of orchestrator in such a context makes it possible to have orchestrators with unbounded buffering capabilities and at the same time to guarantee any message from the client to be eventually delivered by the orchestrator to the server, while preventing the server from sending messages which are kept indefinitely inside the orchestrator. The compliance relation is shown to be decidable by means of 1 a procedure synthesising the orchestrators, if any, making a client compliant with a server, and 2 a procedure for deciding whether an orchestrator behaves in a proper way as mentioned before.

  1. Biopsy of the transplanted kidney--role of protocol biopsies.

    Science.gov (United States)

    Masin-Spasovska, J; Spasovski, G

    2012-01-01

    Traditionally, renal allograft biopsies were performed mainly in the setting of acute graft dysfunction. Recently, there has been a change of paradigms. Several reports suggested that acute rejection of the graft and chronic allograft nephropathy are often subclinical without any deterioration in the graft function. This raises the issue of biopsies in functionally stable allografts (e.g. protocol biopsies) and the clinically useful information they provide. Namely, recent reports provide evidence in favour of treating biopsy-proven subclinical rejections. Moreover, by early identification of chronic histological lesions, protocol biopsies give an opportunity for individualized immunosuppressive regimen and use of targeted therapeutic strategies, in order to prevent chronic allograft dysfunction and improve long-term graft outcome. In this review, diagnostic, therapeutic and research benefit information on protocol biopsies performed in stable kidney recipients are described.

  2. Sepsis and 'superbugs': should we favour the transperineal over the transrectal approach for prostate biopsy?

    Science.gov (United States)

    Grummet, Jeremy P; Weerakoon, Mahesha; Huang, Sean; Lawrentschuk, Nathan; Frydenberg, Mark; Moon, Daniel A; O'Reilly, Mary; Murphy, Declan

    2014-09-01

    To determine the rate of hospital re-admission for sepsis after transperineal (TP) biopsy using both local data and worldwide literature, as there is growing interest in TP biopsy as an alternative to transrectal ultrasonography (TRUS)-guided biopsy for patients undergoing repeat prostate biopsy. Pooled prospective databases on TP biopsy from multiple centres in Melbourne were queried for rates of re-admission for infection. A literature review of PubMed and Embase was also conducted using the search terms: 'prostate biopsy, fever, infection, sepsis, septicaemia and complications'. In all, 245 TP biopsies were performed (111 at Alfred Health, 92 at Epworth Healthcare, 38 at Peter MacCallum Cancer Centre, and four at other institutions). The rate of hospital re-admission for infection was zero. The literature review showed that the rate of sepsis after TRUS biopsy appears to be rising with increasing rates of multi-resistant bacteria found in rectal flora, and is as high as 5%. However, the rate of sepsis from published series of TP biopsy approached zero. Both local and international data suggest a negligible rate of sepsis with TP biopsy. This compares to a concerning rise in the rate of sepsis after TRUS biopsy due to the increasing prevalence of multi-resistant bacteria in rectal flora. Although TRUS biopsy is convenient, cheap and quick to perform, we think that TP biopsy should now be offered as an option, not only to patients undergoing repeat prostate biopsy, but to all patients in whom a prostate biopsy is indicated. © 2013 The Authors. BJU International © 2013 BJU International.

  3. Percutaneous transbiliary biopsy.

    Science.gov (United States)

    Andrade, Gustavo Vieira; Santos, Miguel Arcanjo; Meira, Marconi Roberto; Meira, Mateus Duarte

    2017-01-01

    Percutaneous drainage of the bile ducts is an established procedure for malignant obstructions, in which a histological diagnosis is often not obtained. We describe the biopsy technique of obstructive lesions through biliary drainage access, using a 7F endoscopic biopsy forceps, widely available; some are even reusable. This technique applies to lesions of the hepatic ducts, of the common hepatic duct and of all extension of the common bile duct. RESUMO A drenagem percutânea das vias biliares é um procedimento estabelecido para obstruções malignas, nos quais, muitas vezes, não se consegue um diagnóstico histológico. Descrevemos a técnica de biópsia da lesão obstrutiva através do acesso de drenagem biliar, utilizando um fórcipe de biópsia endoscópica 7F, amplamente disponível e alguns reutilizáveis. Esta técnica aplica-se a lesões dos ductos hepáticos, do hepático comum e de toda extensão do colédoco.

  4. Significant impact of transperineal template biopsy of the prostate at a single tertiary institution

    Directory of Open Access Journals (Sweden)

    Sean Huang

    2015-01-01

    Conclusions: Transperineal biopsy at our institution showed a high rate of disease-upgrading, with a large proportion involving anterior and transition zones. A significant amount of patients went on to receive curative treatment. TPB is a valuable diagnostic procedure with minimal risk of developing urosepsis. We believe TBP should be offered as an option for all repeat prostate biopsies and considered as an option for initial prostate biopsy.

  5. Optimizing Performance and Interpretation of Prostate Biopsy : A Critical Analysis of the Literature

    NARCIS (Netherlands)

    Chun, Felix K. -H.; Epstein, Jonathan I.; Ficarra, Vincenzo; Freedland, Stephen J.; Montironi, Rodolfo; Montorsi, Francesco; Shariat, Shahrokh F.; Schroder, Fritz H.; Scattoni, Vincenzo

    2010-01-01

    Context: The number and location of biopsy cores and the interpretation of prostate biopsy in different clinical settings remain the subjects of continuing debate. Objective: Our aim was to review the current evidence regarding the performance and interpretation of initial, repeat, and saturation pr

  6. Optimizing Performance and Interpretation of Prostate Biopsy : A Critical Analysis of the Literature

    NARCIS (Netherlands)

    Chun, Felix K. -H.; Epstein, Jonathan I.; Ficarra, Vincenzo; Freedland, Stephen J.; Montironi, Rodolfo; Montorsi, Francesco; Shariat, Shahrokh F.; Schroder, Fritz H.; Scattoni, Vincenzo

    2010-01-01

    Context: The number and location of biopsy cores and the interpretation of prostate biopsy in different clinical settings remain the subjects of continuing debate. Objective: Our aim was to review the current evidence regarding the performance and interpretation of initial, repeat, and saturation pr

  7. Mitochondrial Respiration after One Session of Calf Raise Exercise in Patients with Peripheral Vascular Disease and Healthy Older Adults

    Science.gov (United States)

    Wohlwend, Martin; Rognmo, Øivind; Mattsson, Erney J. R.

    2016-01-01

    Purpose Mitochondria are essential for energy production in the muscle cell and for this they are dependent upon a sufficient supply of oxygen by the circulation. Exercise training has shown to be a potent stimulus for physiological adaptations and mitochondria play a central role. Whether changes in mitochondrial respiration are seen after exercise in patients with a reduced circulation is unknown. The aim of the study was to evaluate the time course and whether one session of calf raise exercise stimulates mitochondrial respiration in the calf muscle of patients with peripheral vascular disease. Methods One group of patients with peripheral vascular disease (n = 11) and one group of healthy older adults (n = 11) were included. Patients performed one session of continuous calf raises followed by 5 extra repetitions after initiation of pain. Healthy older adults performed 100 continuous calf raises. Gastrocnemius muscle biopsies were collected at baseline and 15 minutes, one hour, three hours and 24 hours after one session of calf raise exercise. A multi substrate (octanoylcarnitine, malate, adp, glutamate, succinate, FCCP, rotenone) approach was used to analyze mitochondrial respiration in permeabilized fibers. Mixed-linear model for repeated measures was used for statistical analyses. Results Patients with peripheral vascular disease have a lower baseline respiration supported by complex I and they increase respiration supported by complex II at one hour post-exercise. Healthy older adults increase respiration supported by electron transfer flavoprotein and complex I at one hour and 24 hours post-exercise. Conclusion Our results indicate a shift towards mitochondrial respiration supported by complex II as being a pathophysiological component of peripheral vascular disease. Furthermore exercise stimulates mitochondrial respiration already after one session of calf raise exercise in patients with peripheral vascular disease and healthy older adults. Trial

  8. Mitochondrial Respiration after One Session of Calf Raise Exercise in Patients with Peripheral Vascular Disease and Healthy Older Adults.

    Science.gov (United States)

    van Schaardenburgh, Michel; Wohlwend, Martin; Rognmo, Øivind; Mattsson, Erney J R

    2016-01-01

    Mitochondria are essential for energy production in the muscle cell and for this they are dependent upon a sufficient supply of oxygen by the circulation. Exercise training has shown to be a potent stimulus for physiological adaptations and mitochondria play a central role. Whether changes in mitochondrial respiration are seen after exercise in patients with a reduced circulation is unknown. The aim of the study was to evaluate the time course and whether one session of calf raise exercise stimulates mitochondrial respiration in the calf muscle of patients with peripheral vascular disease. One group of patients with peripheral vascular disease (n = 11) and one group of healthy older adults (n = 11) were included. Patients performed one session of continuous calf raises followed by 5 extra repetitions after initiation of pain. Healthy older adults performed 100 continuous calf raises. Gastrocnemius muscle biopsies were collected at baseline and 15 minutes, one hour, three hours and 24 hours after one session of calf raise exercise. A multi substrate (octanoylcarnitine, malate, adp, glutamate, succinate, FCCP, rotenone) approach was used to analyze mitochondrial respiration in permeabilized fibers. Mixed-linear model for repeated measures was used for statistical analyses. Patients with peripheral vascular disease have a lower baseline respiration supported by complex I and they increase respiration supported by complex II at one hour post-exercise. Healthy older adults increase respiration supported by electron transfer flavoprotein and complex I at one hour and 24 hours post-exercise. Our results indicate a shift towards mitochondrial respiration supported by complex II as being a pathophysiological component of peripheral vascular disease. Furthermore exercise stimulates mitochondrial respiration already after one session of calf raise exercise in patients with peripheral vascular disease and healthy older adults. ClinicalTrials.gov NCT01842412.

  9. Histological Value of Duodenal Biopsies

    Directory of Open Access Journals (Sweden)

    Limci Gupta

    2005-01-01

    Full Text Available This study was performed to see the value of histopathological diagnosis in management of patients with duodenal biopsies; to look for correlation of histology and serology in suspected cases of coeliac disease; the reasons for taking duodenal biopsies and whether proper adequate histories are provided on the forms sent with request for histopathological view on duodenal biopsies. Here are the observations of the study followed by the discussion.

  10. Morbidity after percutaneous liver biopsy.

    OpenAIRE

    Lichtman, S; Guzman, C; Moore, D.; Weber, J L; Roberts, E.A.

    1987-01-01

    The safety of percutaneous liver biopsy with a 1.2 mm Menghini needle in infants aged one year or less was investigated. One hundred and eighty four procedures performed from 1975 to 1985 were reviewed. There were no deaths or major complications within 48 hours associated with the procedure. In five instances specific complications occurred: a drop in haemoglobin concentration (three), transient hypotension (one), and haematoma at the biopsy site (one). The result of liver biopsy was diagnos...

  11. Quantification and viability assessment of isolated bovine primordial and primary ovarian follicles retrieved through a standardized biopsy pick-up procedure.

    Science.gov (United States)

    Aerts, J M J; Martinez-Madrid, B; Flothmann, K; De Clercq, J B P; Van Aelst, S; Bols, P E J

    2008-06-01

    The feasibility of repeated collection and enzymatic isolation of large numbers of viable primordial and primary follicles from living donor cows were tested. Ovarian cortical biopsies were collected transvaginally by the Biopsy Pick-Up (BPU) device, a modification of an Ovum Pick-Up instrument. Follicles were enzymatically isolated from the retrieved cortical tissue samples, and follicle viability was determined by a live/dead fluorescent assay. Six cows were subjected to BPU once per week during 4 consecutive weeks, and in each BPU session 4 cortical tissue samples were collected per ovary. Over the 4-week trial period, a total of 1443 primordial and primary follicles were collected, 1358 (94%) of which were primordial and 85 (6%) were primary follicles. In each BPU session, an average 60.1 +/- 10.7 (mean +/- SEM) primordial and primary follicles were isolated per cow. The number of follicles varied considerably throughout the trial period and between cows. Statistical analysis of the data, however, did not support the presence of any distinct trends in the follicle yields over time or between cows. A total of 111 enzymatically isolated follicles were analyzed for viability with fluorescent probes. The vast majority of isolated follicles (92.8%) were totally viable. We conclude that the standardized BPU procedure generates sufficiently large numbers of vital primordial and primary follicles, thus validating BPU as a new tool for research into early bovine follicular development.

  12. Formal description of the OSI session layer: session service

    NARCIS (Netherlands)

    van Sinderen, Marten J.; van Eijk, P.H.J.; Vissers, C.A.; Diaz, M.

    1989-01-01

    The LOTOS formal description of the OSI session service is presented on basis of specification samples from the full description, giving account of how specification styles and session service architectural elements are reflected in the description. Both information (data types) and process

  13. Ultrasound-guided chest biopsies.

    Science.gov (United States)

    Middleton, William D; Teefey, Sharlene A; Dahiya, Nirvikar

    2006-12-01

    Pulmonary nodules that are surrounded by aerated lung cannot be visualized with sonography. Therefore, percutaneous biopsy must be guided with computed tomography or fluoroscopy. Although this restriction only applies to central lung nodules, it has permeated referral patterns for other thoracic lesions and has retarded the growth of ultrasound-guided interventions. Nevertheless, sonography is an extremely flexible modality that can expeditiously guide many biopsy procedures in the thorax. Peripheral pulmonary nodules can be successfully biopsied with success rates exceeding 90% and complications rates of less than 5%. Orienting the probe parallel to the intercostal space facilitates biopsies of peripheral pulmonary nodules. Anterior mediastinal masses that extend to the parasternal region are often easily approachable provided the internal mammary vessels, costal cartilage, and deep great vessels are identified and avoided. Superior mediastinal masses can be sampled from a suprasternal or supraclavicular approach. Phased array probes or tightly curved arrays may provide improved access for biopsies in this location. Posterior mediastinal masses are more difficult to biopsy with ultrasound guidance because of the overlying paraspinal muscles. However, when posterior mediastinal masses extend into the posterior medial pleural region, they can be biopsied with ultrasound guidance. Because many lung cancers metastasize to the supraclavicular nodes, it is important to evaluate the supraclavicular region when determining the best approach to obtain a tissue diagnosis. When abnormal supraclavicular nodes are present, they often are the easiest and safest lesions to biopsy.

  14. Session-based concurrency, reactively

    NARCIS (Netherlands)

    M. Cano (Mauricio); J. Arias (Jaime); J.A. Pérez Parra (Jorge)

    2017-01-01

    textabstractThis paper concerns formal models for the analysis of communication-centric software systems that feature declarative and reactive behaviors. We focus on session-based concurrency, the interaction model induced by session types, which uses (variants of) the Π-calculus as specification

  15. Delayed hemorrhage from hepatic artery after ultrasound-guided percutaneous liver biopsy: A case report

    Institute of Scientific and Technical Information of China (English)

    Fen-Yu Ren; Xi-Xu Piao; Ailian Jin

    2006-01-01

    Percutaneous liver biopsy is considered one of the most important diagnostic tools to evaluate diffuse liver diseases. Pseudoaneurysm of hepatic artery is an unusual complication after ultrasound-guided percutaneous liver biopsy. Delayed hemorrhage occurs much less frequently. We report a case of pseudoaneurysm of the hepatic artery of a 46-year-old man who was admitted for abdominal pain after 4 d of liver biopsy. The bleeding was controlled initially by angiographic embolization.However, recurrent bleeding could not be controlled by repeat angiography, and the patient died 4 d after admission from multiorgan failure. The admittedly rare possibility of delayed hemorrhage should be considered whenever a liver biopsy is performed.

  16. A Structured Group Program for Repeat Dieters.

    Science.gov (United States)

    McNamara, Kathleen

    1989-01-01

    Describes a structured group program for women who repeatedly diet and may be at risk of developing more serious eating disorders. Discusses sessions focusing on eating behavior as well as internal factors that contribute to low body esteem and food and weight preoccupation. Evaluates effectiveness of program by self-reports of members of two…

  17. Significant Molecular and Systemic Adaptations after Repeated Sprint Training in Hypoxia

    Science.gov (United States)

    Faiss, Raphael; Léger, Bertrand; Vesin, Jean-Marc; Fournier, Pierre-Etienne; Eggel, Yan; Dériaz, Olivier; Millet, Grégoire P.

    2013-01-01

    While intermittent hypoxic training (IHT) has been reported to evoke cellular responses via hypoxia inducible factors (HIFs) but without substantial performance benefits in endurance athletes, we hypothesized that repeated sprint training in hypoxia could enhance repeated sprint ability (RSA) performed in normoxia via improved glycolysis and O2 utilization. 40 trained subjects completed 8 cycling repeated sprint sessions in hypoxia (RSH, 3000 m) or normoxia (RSN, 485 m). Before (Pre-) and after (Post-) training, muscular levels of selected mRNAs were analyzed from resting muscle biopsies and RSA tested until exhaustion (10-s sprint, work-to-rest ratio 1∶2) with muscle perfusion assessed by near-infrared spectroscopy. From Pre- to Post-, the average power output of all sprints in RSA was increased (psprints to exhaustion was increased in RSH (9.4±4.8 vs. 13.0±6.2 sprints, psprints throughout RSA test increased to a greater extent (prepeated sprint performance in RSH than in RSN with significant molecular adaptations and larger blood perfusion variations in active muscles. PMID:23437154

  18. Ultrasound- and MRI-Guided Prostate Biopsy

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Ultrasound- and MRI-Guided Prostate Biopsy Ultrasound- and MRI- ... Ultrasound-and MRI-guided Prostate Biopsy? What is Ultrasound- and MRI-guided Prostate Biopsy? Ultrasound- and MRI- ...

  19. Needle biopsy of skeletal muscle: a review of 10 years experience.

    Science.gov (United States)

    Edwards, R H; Round, J M; Jones, D A

    1983-01-01

    Over 1,000 needle biopsies have been carried out at University College Hospital in London. Needle biopsy has been used by us for histochemical and electron microscopic examination of muscle during the diagnosis and treatment of neuropathic and myopathic disorders, for the diagnosis of mitochondrial myopathies, to study the course of recovery in polymyositis, and for investigations into muscle changes in systemic lupus erythematosus (SLE) and other autoimmune conditions. We have developed a microprocessor system for the measurement of muscle fiber areas, and needle biopsy specimens provide suitable material for such measurements. We have also used needle biopsy specimens for studies of protein turnover using stable isotopes and for trace metal and electrolyte analyses. Needle biopsy is safe and rapid. As the patient usually experiences only minimal discomfort and there is no permanent scar, repeat biopsies are well tolerated allowing follow-up studies after treatment.

  20. Biopsy results of Bosniak 2F and 3 cystic lesions

    DEFF Research Database (Denmark)

    Rasmussen, René; Hørlyck, Arne; Nielsen, Tommy Kjærgaard

    Purpose: The distinction between benign and malignant complex cystic renal lesions remains a challenge. Bosniak 2F lesions are often followed with repeated CT for a minimum of five years, often entailing a high exposure to radiation. The aim of the present study was to evaluate whether biopsy could...... be helpful in clinical decisions. Material and Methods: From March 2013 - December 2014 a total of 295 percutaneous ultrasound guided biopsies from 287 patients with a suspected malignant renal lesion were performed at our institution. All cases were reviewed in PACS by (RR) and lesions presenting...... with a cystic change were re-evaluated and re-categorized after the Bosniak classification system. The re-evaluation and re-categorization was performed in consensus by a junior radiologist (RR) and an uro-radiological expert (OG). Results: Biopsies from eighteen Bosniak 2F cystic lesions were pathologically...

  1. Getting the Most Out of Liver Biopsy.

    Science.gov (United States)

    Lidbury, Jonathan A

    2017-05-01

    Histopathologic evaluation of liver biopsy specimens yields information that is not otherwise obtainable and is frequently essential for diagnosing hepatic disease. Percutaneous needle biopsy, laparoscopic biopsy, and surgical biopsy each have their own set of advantages and disadvantages. Care should be taken to ensure an adequate amount of tissue is collected for meaningful histologic evaluation. Because sampling error is a limitation of hepatic biopsy, multiple liver lobes should be biopsied. This article discusses the indications for liver biopsy, associated risks, advantages and disadvantages of different biopsy techniques, and strategies to get the most useful information possible out of this process. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Endoscopic duodenal biopsy in children

    Directory of Open Access Journals (Sweden)

    El Mouzan Mohammad

    2006-01-01

    Full Text Available Background: Biopsy of the small bowel is frequently obtained by endoscopic forceps instead of the classical suction capsule, yet reports from developing countries are scarce. Aim of the study: to report our experience on the diagnostic value of this procedure in our community. Patients and methods: A retrospective analysis of all endoscopic duodenal biopsies (EDB, performed on all patients below 18 years of age. Data retrieved from the records included age, gender, nationality, indication for biopsy, the endoscopic findings, and the results of histopathology. Results: From 1993 to 2002, 241 endoscopic biopsies were performed on 241 consecutive children. Most of the children (96% were Saudi nationals, the age range between six weeks to 18 years, and male to female ratio was 0.7: 1. All of the biopsy material was adequate for routine histopathology. The commonest indications for biopsy were short stature and chronic diarrhea in 116/241 (48% and 102/241 (43% of the children respectively. Refractory rickets accounted for 11/241 (5% of the indications. The prevalence of villous atrophy was highest in children presenting with chronic diarrhea (40%, compared to short stature (22%. Other less common, but important findings were villous atrophy in three unusual conditions (one refractory rickets, one unexplained anemia, and one polyendocrinopathy, two cases of intestinal Giardia lamblia infestation, three cases of intestinal lymphangiectasis and one case of Mycobacterium avium intracellulare. Unexpected endoscopic findings were documented in 34/241 (14% of the children. Conclusions: Endoscopic duodenal biopsy is adequate not only for the diagnosis of villous atrophy, but also for the detection of other gastroenteropathies. Accordingly, when expertise and equipments are available, EDB should be the procedure of choice not only in industrialized but also in developing countries.

  3. Sessions and Separability in Security Protocols

    DEFF Research Database (Denmark)

    Carbone, Marco; Guttman, Joshua

    2013-01-01

    Despite much work on sessions and session types in non- adversarial contexts, session-like behavior given an active adversary has not received an adequate definition and proof methods. We provide a syntactic property that guarantees that a protocol has session-respecting executions. Any uncomprom......Despite much work on sessions and session types in non- adversarial contexts, session-like behavior given an active adversary has not received an adequate definition and proof methods. We provide a syntactic property that guarantees that a protocol has session-respecting executions. Any......- work, and gives a general pattern for reasoning about independence....

  4. Vienna SAC-SOS: Analysis of the European VLBI Sessions

    Science.gov (United States)

    Ros, C. T.; Pavetich, P.; Nilsson, T.; Böhm, J.; Schuh, H.

    2012-12-01

    The Institute of Geodesy and Geophysics (IGG) of the Vienna University of Technology as an IVS Special Analysis Center for Specific Observing Sessions (SAC-SOS) has analyzed the European VLBI sessions using the software VieVS. Between 1990 and 2011, 115 sessions have been carried out. The analyzed baselines have lengths ranging from approximately 445 to 4580 km, and they show good repeatabilities, apart from the ones containing station Simeiz. The station velocities have also been investigated. The stations situated in the stable part of Europe have not shown significant relative movements w.r.t. Wettzell, whereas the stations located in the northern areas have the largest vertical motions as a result of the post glacial isostatic rebound of the zone. The stations placed in Italy, around the Black Sea, in Siberia, and near the Arctic Circle show the largest relative horizontal motions because they belong to different geodynamical units.

  5. Protocol biopsies for renal transplantation

    Directory of Open Access Journals (Sweden)

    Rush David

    2010-01-01

    Full Text Available Protocol biopsies in renal transplantation are those that are procured at predetermined times post renal transplantation, regardless of renal function. These biopsies have been useful to study the natural history of the transplanted kidney as they have detected unexpected - i.e. "subclinical" pathology. The most significant subclinical pathologies that have been detected with protocol biopsies have been acute lesions, such as cellular and antibody mediated rejection, and chronic lesions, such as interstitial fibrosis and tubular atrophy, and transplant glomerulopathy. The potential benefit of early recognition of the above lesions is that their early treatment may result in improved long-term outcomes. Conversely, the identification of normal histology on a protocol biopsy, may inform us about the safety of reduction in overall immunosuppression. Our centre, as well as others, is attempting to develop non-invasive methods of immune monitoring of renal transplant patients. However, we believe that until such methods have been developed and validated, the protocol biopsy will remain an indispensable tool for the complete care of renal transplant patients.

  6. Sugar and acid interconversion in tomato fruits based on biopsy sampling of locule gel and pericarp tissue

    NARCIS (Netherlands)

    Schouten, R.E.; Woltering, E.J.; Tijskens, L.M.M.

    2016-01-01

    This study deals with quantifying sugar and acids levels important for the perceived taste of tomatoes (Solanum lycopersicum). Sugar and acids levels were measured repeatedly on the same tomato using tissue samples obtained with a biopsy needle in combination with HPLC protocols. Biopsies of

  7. Systematic ultrasound-guided saturation and template biopsy of the prostate: Indications and advantages of extended sampling

    NARCIS (Netherlands)

    Isbarn, H.; Briganti, B.; Visschere, P.J. De; Futterer, J.J.; Ghadjar, P.; Giannarini, G.; Ost, P.; Ploussard, G.; Sooriakumaran, P.; Surcel, C.; Oort, I.M. van; Yossepowitch, O.; Bergh, R. van den

    2015-01-01

    OBJECTIVES: Prostate biopsy (PB) is the gold standard for the diagnosis of prostate cancer (PCa). However, the optimal number of biopsy cores remains debatable. We sought to compare contemporary standard (10-12 cores) vs. saturation (=18 cores) schemes on initial as well as repeat PB. METHODS: A non

  8. Systematic ultrasound-guided saturation and template biopsy of the prostate: Indications and advantages of extended sampling

    NARCIS (Netherlands)

    Isbarn, H.; Briganti, B.; Visschere, P.J. De; Futterer, J.J.; Ghadjar, P.; Giannarini, G.; Ost, P.; Ploussard, G.; Sooriakumaran, P.; Surcel, C.; Oort, I.M. van; Yossepowitch, O.; Bergh, R. van den

    2015-01-01

    OBJECTIVES: Prostate biopsy (PB) is the gold standard for the diagnosis of prostate cancer (PCa). However, the optimal number of biopsy cores remains debatable. We sought to compare contemporary standard (10-12 cores) vs. saturation (=18 cores) schemes on initial as well as repeat PB. METHODS: A

  9. Repeat-until-success quantum repeaters

    Science.gov (United States)

    Bruschi, David Edward; Barlow, Thomas M.; Razavi, Mohsen; Beige, Almut

    2014-09-01

    We propose a repeat-until-success protocol to improve the performance of probabilistic quantum repeaters. Conventionally, these rely on passive static linear-optics elements and photodetectors to perform Bell-state measurements (BSMs) with a maximum success rate of 50%. This is a strong impediment for entanglement swapping between distant quantum memories. Every time a BSM fails, entanglement needs to be redistributed between the corresponding memories in the repeater link. The key ingredients of our scheme are repeatable BSMs. Under ideal conditions, these turn probabilistic quantum repeaters into deterministic ones. Under realistic conditions, our protocol too might fail. However, using additional threshold detectors now allows us to improve the entanglement generation rate by almost orders of magnitude, at a nominal distance of 1000 km, compared to schemes that rely on conventional BSMs. This improvement is sufficient to make the performance of our scheme comparable to the expected performance of some deterministic quantum repeaters.

  10. Motorized fusion guided prostate biopsy: phantom study

    Science.gov (United States)

    Seifabadi, Reza; Xu, Sheng; Aalamifar, Fereshteh; Pinto, Peter; Wood, Bradford J.

    2017-03-01

    Purpose: Fusion of Magnetic Resonance Imaging (MRI) with intraoperative real-time Ultrasound (US) during prostate biopsy has significantly improved the sensitivity of transrectal ultrasound (TRUS) guided cancer detection. Currently, sweeping of the TRUS probe to build a 3D volume as part of the fusion process and the TRUS probe manipulation for needle guidance are both done manually. A motorized, joystick controlled, probe holder was custom fabricated that can potentially reduce inter-operator variability, provide standardization of needle placement, improve repeatability and uniformity of needle placement, which may have impacts upon the learning curve after clinical deployment of this emerging approach. Method: a 2DOF motorized probe holder was designed to provide translation and rotation of a triplane TRUS end firing probe for prostate biopsy. The probe holder was joystick controlled and can assist manipulation of the probe during needle insertion as well as in acquiring a smoother US 2D to 3D sweep in which the 3D US volume for fusion is built. A commercial MRI-US fusion platform was used. Three targets were specified on MR image of a commercial prostate phantom. After performing the registration, two operators performed targeting, once manually and once with the assistance of the motorized probe holder. They repeated these tasks 5 times resulting in a total of 30 targeting events. Time of completion and mechanical error i.e. distance of the target from the needle trajectory in the software user interface were measured. Repeatability in reaching a given target in a systematic and consistent way was measured using a scatter plot showing all targets in the US coordinate system. Pearson product-moment correlation coefficient (PPMCC) was used to demonstrate the probe steadiness during targeting. Results: the completion time was 25+/-17 sec, 25+/-24 sec, and 27+/-15 sec for free hand and 24+/-10 sec, 22.5+/-10 sec, and 37+/-10 sec for motorized insertion, for target

  11. Secure Sessions for Web Services

    NARCIS (Netherlands)

    Bhargavan, K.; Corin, R.J.; Fournet, C.; Gordon, A.D.

    2004-01-01

    WS-Security provides basic means to secure SOAP traffic, one envelope at a time. For typical web services, however, using WS-Security independently for each message is rather inefficient; besides, it is often important to secure the integrity of a whole session, as well as each message. To this end,

  12. Significant molecular and systemic adaptations after repeated sprint training in hypoxia.

    Directory of Open Access Journals (Sweden)

    Raphael Faiss

    Full Text Available While intermittent hypoxic training (IHT has been reported to evoke cellular responses via hypoxia inducible factors (HIFs but without substantial performance benefits in endurance athletes, we hypothesized that repeated sprint training in hypoxia could enhance repeated sprint ability (RSA performed in normoxia via improved glycolysis and O(2 utilization. 40 trained subjects completed 8 cycling repeated sprint sessions in hypoxia (RSH, 3000 m or normoxia (RSN, 485 m. Before (Pre- and after (Post- training, muscular levels of selected mRNAs were analyzed from resting muscle biopsies and RSA tested until exhaustion (10-s sprint, work-to-rest ratio 1:2 with muscle perfusion assessed by near-infrared spectroscopy. From Pre- to Post-, the average power output of all sprints in RSA was increased (p<0.01 to the same extent (6% vs 7%, NS in RSH and in RSN but the number of sprints to exhaustion was increased in RSH (9.4±4.8 vs. 13.0±6.2 sprints, p<0.01 but not in RSN (9.3±4.2 vs. 8.9±3.5. mRNA concentrations of HIF-1α (+55%, carbonic anhydrase III (+35% and monocarboxylate transporter-4 (+20% were augmented (p<0.05 whereas mitochondrial transcription factor A (-40%, peroxisome proliferator-activated receptor gamma coactivator 1α (-23% and monocarboxylate transporter-1 (-36% were decreased (p<0.01 in RSH only. Besides, the changes in total hemoglobin variations (Δ[tHb] during sprints throughout RSA test increased to a greater extent (p<0.01 in RSH. Our findings show larger improvement in repeated sprint performance in RSH than in RSN with significant molecular adaptations and larger blood perfusion variations in active muscles.

  13. Biopsy techniques for intraocular tumors

    Directory of Open Access Journals (Sweden)

    Pukhraj Rishi

    2016-01-01

    Full Text Available Biopsy involves the surgical removal of a tissue specimen for histopathologic evaluation. Most intraocular tumors are reliably diagnosed based on the clinical evaluation or with noninvasive diagnostic techniques. However, accurately diagnosing a small percentage of tumors can be challenging. A tissue biopsy is thus needed to establish a definitive diagnosis and plan the requisite treatment. From fine-needle aspiration biopsy (FNAB to surgical excision, all tissue collection techniques have been studied in the literature. Each technique has its indications and limitations. FNAB has been reported to provide for 88-95% reliable and safe ophthalmic tumor diagnosis and has gained popularity for prognostic purposes and providing eye conserving treatment surgeries. The technique and instrumentation for biopsy vary depending upon the tissue involved (retina, choroid, subretinal space, vitreous, and aqueous, suspected diagnosis, size, location, associated retinal detachment, and clarity of the media. The cytopathologist confers a very important role in diagnosis and their assistance plays a key role in managing and planning the treatment for malignancies.

  14. Vacuum enhanced cutaneous biopsy instrument

    Science.gov (United States)

    Collins, Joseph

    2000-01-01

    A syringe-like disposable cutaneous biopsy instrument equipped with a tubular blade at its lower end, and designed so that a vacuum is created during use, said vacuum serving to retain undeformed a plug of tissue cut from a patient's skin.

  15. Spectrum of pediatric skin biopsies

    Directory of Open Access Journals (Sweden)

    Grace D′costa

    2007-01-01

    Full Text Available Background: Skin diseases are common in childhood and they are common reasons for pediatric visits to the hospital. In spite of this high occurrence, there are very few prospective studies addressing this issue. Aims: The present study was directed at determining the spectrum of dermato-pathological lesions encountered in a large general tertiary care hospital, over a two-year period. Materials and Methods: 107 cases formed the total sample studied, in a part prospective and part retrospective study. A detailed clinical history was recorded on a proforma prepared for the purpose and gross photographs were taken wherever possible. Results: Skin biopsies accounted for 7.29% of the total surgical pathology load, 55.44% of the total pediatric biopsies and 10.82% of the total number of skin biopsies. The age and sex distribution pattern revealed that the maximum number of biopsies (62.61% were of older children, with a male preponderance (57.94%. The anatomic distribution pattern indicated predominant involvement of the limbs (59.82%. The maximum numbers of cases were of infectious nature (24.29%; the most frequently encountered being borderline tuberculoid Hansen′s disease (8.4%. A positive correlation with the clinical diagnosis was obtained in 56.07% cases. Conclusions: Histopathology contributed to the diagnosis in a significant number of (82.23% cases, indicating its importance and utility.

  16. Biopsy techniques for intraocular tumors

    Science.gov (United States)

    Rishi, Pukhraj; Dhami, Abhinav; Biswas, Jyotirmay

    2016-01-01

    Biopsy involves the surgical removal of a tissue specimen for histopathologic evaluation. Most intraocular tumors are reliably diagnosed based on the clinical evaluation or with noninvasive diagnostic techniques. However, accurately diagnosing a small percentage of tumors can be challenging. A tissue biopsy is thus needed to establish a definitive diagnosis and plan the requisite treatment. From fine-needle aspiration biopsy (FNAB) to surgical excision, all tissue collection techniques have been studied in the literature. Each technique has its indications and limitations. FNAB has been reported to provide for 88–95% reliable and safe ophthalmic tumor diagnosis and has gained popularity for prognostic purposes and providing eye conserving treatment surgeries. The technique and instrumentation for biopsy vary depending upon the tissue involved (retina, choroid, subretinal space, vitreous, and aqueous), suspected diagnosis, size, location, associated retinal detachment, and clarity of the media. The cytopathologist confers a very important role in diagnosis and their assistance plays a key role in managing and planning the treatment for malignancies. PMID:27488148

  17. The Role of Biopsy in Pediatric Dermatopathology

    Directory of Open Access Journals (Sweden)

    Fatma Şule Afşa

    2011-09-01

    Full Text Available Background and Design: Pediatric dermatology is characterized by skin disorders which have frequencies different from those in adults. Skin biopsies are necessary for differential diagnosis and clinicopathologic correlation is very important. The aim of this study was to evaluate retrospectively the pediatric dermatology cases in whom biopsy was performed for differential diagnosis and to investigate the contribution of biopsy to diagnosis of skin disorders. Material and Methods: The cases from whom biopsy was taken in the pediatric dermatology clinic during a three-year period were evaluated retrospectively for pre-diagnoses, biopsy diagnoses, and success of biopsies.Results: Two hundred thirteen (1.7% skin biopsies had been taken from a total of 12420 patients. Henoch-Schönlein purpura, psoriasis, pityriasis lichenoides, pityriasis rosea, lichen planus, pityriasis rubra pilaris, erythema multiforme, atopic dermatitis, granuloma annulare, and pigmented purpuric dermatosis were the most frequent skin disorders diagnosed dermatopathologically. In a total of 120 (56.3% cases, the biopsy diagnosis was within the pre-diagnosis and a biopsy consistency was present. In 25 (11.7% cases, biopsy had no contribution to the differential diagnosis. An absolutely different diagnosis which was incompatible with the pre-diagnosis had been reported in 10 (4.6% cases. Conclusion: In pediatric dermatology, skin biopsy is very helpful for the differential diagnosis. An easy biopsy procedure for the patient, an effective designation of biopsy indication, a good dermatopathologic correlation and an experienced team of pediatric dermatopathology increase the success of skin biopsies.

  18. Retroperitoneoscopic renal biopsy in children

    Directory of Open Access Journals (Sweden)

    Carlos M. Jesus

    2007-08-01

    Full Text Available OBJECTIVE: We present our experience in a series of 17 consecutive pediatric patients submitted to retroperitoneal laparoscopic renal biopsy. MATERIALS AND METHODS: Retroperitoneal laparoscopic renal biopsy (LRB was performed in 5 boys and 12 girls. Mean age was 8.1 years and age range from 2 to 12. Two or three trocars were used to expose the inferior pole of the kidney, remove enough cortical parenchymal specimen and fulgurate the biopsy site. Assessment included surgical time, estimated blood loss, hospitalization period, analgesia requirements, complications and number of glomeruli present in the specimen. RESULTS: LRB was successfully performed in all 15 patients (88%. In two cases, LRB was not possible to be performed. One patient was converted to a transperitoneal laparoscopy due to tear in the peritoneum. The other patient had had previous abdominal surgery and, during retroperitoneal balloon dilation, the peritoneum was opened and the open biopsy was performed. A third patient had postoperatively a perirenal hematoma, which was solved spontaneously. Complication rate was 17.6% (3/17 cases. Mean operative time was 65 minutes, while mean estimated blood loss was 52 mL, mean hospital stay was 2.2 days and mean analgesic requirement was 100 mg of tramadol. The mean number of glomeruli present in the specimen was 60. CONCLUSION: Retroperitoneal laparoscopic renal biopsy in children is a simple, safe. Bleeding is still the most common complication. However, direct vision usually allows a safe control of this drawback. In our institution, laparoscopic approach is the chosen procedure in pediatric patients older than one - year - old.

  19. When to biopsy seminal vesicles.

    Science.gov (United States)

    Panach-Navarrete, J; García-Morata, F; Hernández-Medina, J A; Martínez-Jabaloyas, J M

    2015-05-01

    The involvement of seminal vesicles in prostate cancer can affect the prognosis and determine the treatment. The objective of this study was to determine whether we could predict its infiltration at the time of the prostate biopsy to know when to indicate the biopsy of the seminal vesicles. observational retrospective study of 466 patients who underwent seminal vesicle biopsy. The indication for this biopsy was a prostate-specific antigen (PSA) level greater than 10 ng/ml or an asymmetric or obliterated prostatoseminal angle. The following variables were included in the analysis: PSA level, PSA density, prostate volume, number of cores biopsied, suspicious rectal examination, and preservation of the prostatoseminal angle, studying its relationship with the involvement of the seminal vesicles. Forty-one patients (8.8%) had infiltrated seminal vesicles and 425 (91.2%) had no involvement. In the univariate analysis, the cases with infiltration had a higher mean PSA level (P 19.60 ng/dL (P < .01) and 2.95 times higher if there is a suspicious rectal examination (P = .014). Furthermore, this probability increases by 1.04 times for each unit of prostate volume lower (P < .01). The ROC curves showed maximum sensitivity and specificity at 19.6 ng/mL for PSA and 0.39 for PSA density. In this series, greater involvement of seminal vesicles was associated with a PSA level ≥20 ng/ml, a suspicious rectal examination and a lack of prostatoseminal angle preservation. Copyright © 2014 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. Comparative Study of Core Needle Biopsy and Fine Needle Aspiration Cytology in Palpable Breast Lumps: Scenario in Developing Nations.

    Science.gov (United States)

    Tikku, Gargi; Umap, Pradeep

    2016-01-01

    The purpose of this study was to evaluate the utility of core needle biopsy as a diagnostic tool for palpable breast lumps in developing countries as compared to fine needle aspiration cytology. All patients attending the surgery outpatient department with palpable breast lumps were subjected to fine needle aspiration cytology and core needle biopsy by the same operator in a single session. Fine needle aspiration cytology was performed by the standard technique. Core needle biopsy was done freehand using a 14G manual core biopsy needle. Reporting categories of the two techniques were taken from the standard National Health Service Breast Screening Programme criteria and were compared with the final histopathology results. A total of 107 patients underwent fine needle aspiration cytology and core needle biopsy simultaneously. Histopathology was available for 85 cases. Statistical analysis of fine needle aspiration cytology and core needle biopsy showed no significant difference between the diagnoses offered by core needle biopsy and histopathology while there was a significant difference between fine needle aspiration cytology and histopathology diagnoses. Core needle biopsy detected more breast carcinomas as compared to fine needle aspiration cytology with a sensitivity 95.83% as opposed to 64.58%. Though both the techniques were equally specific (100%), Core needle biopsy was able to correctly categorize borderline / inadequate lesions into definitely benign and malignant categories. We suggest that core needle biopsy should be preferred over fine needle aspiration cytology for the diagnosis of palpable breast lumps with fine needle aspiration cytology being reserved for definitely benign lesions.

  1. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking.......To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  2. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking.......To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  3. The use of a short-acting benzodiazepine to reduce the risk of syncopal episodes during upright stereotactic breast biopsy

    Energy Technology Data Exchange (ETDEWEB)

    James, J.J. [Breast Institute, Nottingham City Hospital, Hucknall Road, Nottingham NG5 1PB (United Kingdom)]. E-mail: jjames3@ncht.trent.nhs.uk; Wilson, A.R.M. [Breast Institute, Nottingham City Hospital, Hucknall Road, Nottingham NG5 1PB (United Kingdom); Evans, A.J. [Breast Institute, Nottingham City Hospital, Hucknall Road, Nottingham NG5 1PB (United Kingdom); Burrell, H. [Breast Institute, Nottingham City Hospital, Hucknall Road, Nottingham NG5 1PB (United Kingdom); Cornford, E.J. [Breast Institute, Nottingham City Hospital, Hucknall Road, Nottingham NG5 1PB (United Kingdom); Hamilton, L.J. [Breast Institute, Nottingham City Hospital, Hucknall Road, Nottingham NG5 1PB (United Kingdom)

    2005-03-01

    The use of sublingual lorazepam provides a safe and effective means of reducing the risk of syncopal episodes during upright stereotactic breast biopsy. Sublingual lorazepam, 2-4 mg, was received by 19 women undergoing a total of 20 stereotactic procedures. Of 14 women who had previously fainted during upright stereotactic biopsy, 13 had a successful repeat biopsy following administration of sublingual lorazepam. All 4 women who received lorazepam for significant anxiety had successful biopsies. Stereotactic guided wire localization also was performed in 2 cases.

  4. Beam instability Workshop - plenary sessions

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    The purpose of this workshop was to provide a review of the mechanisms of limiting beam instabilities, their cures, including feedback, and beam measurement for synchrotron radiation light sources. 12 plenary sessions took place whose titles are: 1) challenging brilliance and lifetime issues with increasing currents; 2) limiting instabilities in multibunch; 3) experience from high currents in B factories; 4) longitudinal dynamics in high intensity/bunch; 5) Transverse instabilities for high intensity/bunch; 6) working group introduction from ESRF experience; 7) impedance modelling: simulations, minimization; 8) report on the broadband impedance measurements and modelling workshop; 9) feedback systems for synchrotron light sources; 10) beam instabilities diagnostics; 11) harmonic cavities: the pros and cons; and 12) experimental study of fast beam-ion instabilities at PLS. This document gathers the 12 articles that were presented during these sessions.

  5. Introduction to Session 1B

    Science.gov (United States)

    Sticklen, Mariam B.

    Topics presented in the "Plant Biotechnology and Genomics" session focused on technologies that highlight the important role of plant biotechnology and genomics in the development of future energy crops. Several excellent presentations demonstrated the latest advances in energy crop development through the use of plant cell wall regulation and by engineering new energy crops such as brown midrib sweet sorghum. Approaches included the control of cellulose production by increased expression of cellulase synthase genes and the selection of high-yield varieties of shrub willows. The potential of producing hydrolytic enzymes using transgenic plants as a cost-effective means for the large-scale production of these enzymes was also explored in the session, as was the role of posttranslational modifications on the activities of heterologous expressed cellulases in hosts such as Pichia pastoris.

  6. SIRA: TREC Session Track 2014

    Science.gov (United States)

    2014-11-01

    including query topics, initial retrieved webpages , clicked on links, visit times, etc. SIRA has used several methods to improve search results that...sessions include many aspects of a search, including query topics, initial retrieved webpages , clicked on links, visit times, etc. SIRA has used several...which was designed for intelligence analysts researching weapons of mass destruction [5]. In these domains, a small number of specific frames can

  7. Testing Biopsy and Cytology Specimens for Cancer

    Science.gov (United States)

    ... Your Diagnosis Exams and Tests for Cancer Testing Biopsy and Cytology Specimens for Cancer Waiting to hear ... who tell you whether the cells in your biopsy sample are cancer or not. How is cancer ...

  8. Melanoma Biopsy Results Can Differ, Worrying Patients

    Science.gov (United States)

    ... page: https://medlineplus.gov/news/fullstory_166955.html Melanoma Biopsy Results Can Differ, Worrying Patients Doctor discovers ... her dermatologist said her skin biopsy indicated possible melanoma, she knew just what to do -- get a ...

  9. Tissue Biopsies in Diabetes Research

    DEFF Research Database (Denmark)

    Højlund, Kurt; Gaster, Michael; Beck-Nielsen, Henning

    2007-01-01

    Type 2 diabetes is characterized by insulin resistance in major metabolic tissues such as skeletal muscle, liver and fat cells, and failure of the pancreatic ß-cells to compensate for this abnormality (1,2). Skeletal muscle is the major site of glucose disposal in response to insulin, and insulin...... resistance of glucose disposal and glycogen synthesis in this tissue are hallmark features of type 2 diabetes in humans (2,3). During the past two decades, we have carried out more than 1200 needle biopsies of skeletal muscle to study the cellular mechanisms underlying insulin resistance in type 2 diabetes....... Together with morphological studies, measurement of energy stores and metabolites, enzyme activity and phosphorylation, gene and protein expression in skeletal muscle biopsies have revealed a variety of cellular abnormalities in patients with type 2 diabetes and prediabetes. The possibility to establish...

  10. Testicular biopsy in prepubertal boys

    DEFF Research Database (Denmark)

    Faure, Alice; Bouty, Aurore; O'Brien, Mike

    2016-01-01

    in undervirilized patients with 46,XY disorders of sexual development. Testicular histology is also of considerable value in the prediction of both fertility potential and risk of cancer in individuals with undescended testes, particularly those with intraabdominal undescended testes. New possibilities......No consensus exists regarding the precise role of testicular biopsy in prepubertal boys, although it is considered useful for assessing the potential consequences of undescended testes on fertility. Current scientific knowledge indicates that surgeons should broaden indications for this procedure...... for the preservation of fertility after gonadotoxic chemotherapy - even for prepubertal boys - are emerging. Cryopreservation of testicular tissue samples for the preservation of fertility - although still an experimental method at present - is appealing in this context. In our opinion, testicular biopsy...

  11. A Video Recall Study of In-session Changes in Sentiment Override.

    Science.gov (United States)

    Johnson, Lee N; Tambling, Rachel B; Anderson, Shayne R

    2015-09-01

    This study examines in-session changes in sentiment override over the first three sessions of couple therapy. Couples viewed a video recording of therapy sessions immediately after each of the first three sessions and continuously rated their level of sentiment override. Ninety-eight changes were randomly chosen for analysis. Three talk turns prior to each change was coded using the Family Relational Communication Control Coding System. Results show that changes in sentiment override occur frequently. Repeated incidents of communication control were related to negative change in sentiment override for females. Repeated incidents of being left out of the conversation were related to negative changes in sentiment override for females and positive changes for males. © 2014 Family Process Institute.

  12. PCA3 and PCA3-Based Nomograms Improve Diagnostic Accuracy in Patients Undergoing First Prostate Biopsy

    Directory of Open Access Journals (Sweden)

    Virginie Vlaeminck-Guillem

    2013-08-01

    Full Text Available While now recognized as an aid to predict repeat prostate biopsy outcome, the urinary PCA3 (prostate cancer gene 3 test has also been recently advocated to predict initial biopsy results. The objective is to evaluate the performance of the PCA3 test in predicting results of initial prostate biopsies and to determine whether its incorporation into specific nomograms reinforces its diagnostic value. A prospective study included 601 consecutive patients addressed for initial prostate biopsy. The PCA3 test was performed before ≥12-core initial prostate biopsy, along with standard risk factor assessment. Diagnostic performance of the PCA3 test was evaluated. The three available nomograms (Hansen’s and Chun’s nomograms, as well as the updated Prostate Cancer Prevention Trial risk calculator; PCPT were applied to the cohort, and their predictive accuracies were assessed in terms of biopsy outcome: the presence of any prostate cancer (PCa and high-grade prostate cancer (HGPCa. The PCA3 score provided significant predictive accuracy. While the PCPT risk calculator appeared less accurate; both Chun’s and Hansen’s nomograms provided good calibration and high net benefit on decision curve analyses. When applying nomogram-derived PCa probability thresholds ≤30%, ≤6% of HGPCa would have been missed, while avoiding up to 48% of unnecessary biopsies. The urinary PCA3 test and PCA3-incorporating nomograms can be considered as reliable tools to aid in the initial biopsy decision.

  13. Repeated Prolonged Exercise Decreases Maximal Fat Oxidation in Older Men

    DEFF Research Database (Denmark)

    Morville, Thomas; Rosenkilde, Mads; Munch-Andersen, Thor

    2017-01-01

    INTRODUCTION/PURPOSE: Fat metabolism and muscle adaptation was investigated in 6 older trained men (age: 61 ± 4 years; VO2max: 48 ± 2 mL kg min) following repeated prolonged exercise). METHODS: 2706 km (1,681 miles) cycling was performed over 14 days and a blood sample and a muscle biopsy were...

  14. Advances in Liquid Biopsy and its Clinical Application in the Diagnosis 
and Treatment of Non-small Cell Lung Cancer

    Directory of Open Access Journals (Sweden)

    Difan ZHENG

    2016-06-01

    Full Text Available With the advances of technology, great progresses have been made in liquid biopsy in recent years. Liquid biopsy is currently playing a more and more important role in early diagnosis and treatment of cancer. Compared with traditional tissue biopsy, liquid biopsy is more popular in clinical practice due to its non-invasiveness, convenience and high repeatability. It has huge potential in the future. This review introduces circulating tumor cells (CTCs and circulating tumor DNA (ctDNA as the most important objects in liquid biopsy, mainly focusing on their history, biological characteristics, detection technologies, limitations and applications in non-small cell lung cancer.

  15. 20 CFR 718.106 - Autopsy; biopsy.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Autopsy; biopsy. 718.106 Section 718.106... PNEUMOCONIOSIS Criteria for the Development of Medical Evidence § 718.106 Autopsy; biopsy. (a) A report of an autopsy or biopsy submitted in connection with a claim shall include a detailed gross macroscopic and...

  16. Breast magnetic resonance imaging guided biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Bo La; Kim, Sun Mi; Jang, Mi Jung [Dept. of Radiology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of); Cho, Nariya; Moon, Woo Kyung [Dept. of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of); Kim, Hak Hee [Dept. of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2016-06-15

    Despite the high sensitivity of breast magnetic resonance imaging (MRI), pathologic confirmation by biopsy is essential because of limited specificity. MRI-guided biopsy is required in patients with lesions only seen on MRI. We review preprocedural considerations and the technique of MRI-guided biopsy, challenging situations and trouble-shooting, and correlation of radiologic and pathologic findings.

  17. Parotid gland biopsy compared with labial biopsy in the diagnosis of patients with primary Sjogren's syndrome

    NARCIS (Netherlands)

    Pijpe, J.; Kalk, W. W. I.; van der Wal, J. E.; Vissink, A.; Kluin, Ph. M.; Roodenburg, J. L. N.; Bootsma, H.; Kallenberg, C. G. M.; Spijkervet, F. K. L.

    2007-01-01

    Objective. To assess the value of the parotid biopsy as a diagnostic tool for primary Sjogren's syndrome ( pSS), and to compare the parotid biopsy and the labial biopsy with regard to diagnostic value and biopsy-related morbidity. Methods. In 15 consecutive patients with pSS and 20 controls, the par

  18. Parotid gland biopsy compared with labial biopsy in the diagnosis of patients with primary Sjogren's syndrome

    NARCIS (Netherlands)

    Pijpe, J.; Kalk, W. W. I.; van der Wal, J. E.; Vissink, A.; Kluin, Ph. M.; Roodenburg, J. L. N.; Bootsma, H.; Kallenberg, C. G. M.; Spijkervet, F. K. L.

    2007-01-01

    Objective. To assess the value of the parotid biopsy as a diagnostic tool for primary Sjogren's syndrome ( pSS), and to compare the parotid biopsy and the labial biopsy with regard to diagnostic value and biopsy-related morbidity. Methods. In 15 consecutive patients with pSS and 20 controls, the par

  19. Institutional computing (IC) information session

    Energy Technology Data Exchange (ETDEWEB)

    Koch, Kenneth R [Los Alamos National Laboratory; Lally, Bryan R [Los Alamos National Laboratory

    2011-01-19

    The LANL Institutional Computing Program (IC) will host an information session about the current state of unclassified Institutional Computing at Los Alamos, exciting plans for the future, and the current call for proposals for science and engineering projects requiring computing. Program representatives will give short presentations and field questions about the call for proposals and future planned machines, and discuss technical support available to existing and future projects. Los Alamos has started making a serious institutional investment in open computing available to our science projects, and that investment is expected to increase even more.

  20. Working session 3: Tubing integrity

    Energy Technology Data Exchange (ETDEWEB)

    Cueto-Felgueroso, C. [Tecnatom, S.A., San Sebastian de los Reyes, Madrid (Spain); Strosnider, J. [NRC, Washington, DC (United States)

    1997-02-01

    Twenty-three individuals representing nine countries (Belgium, Canada, the Czech Republic, France, Japan, the Slovak Republic, Spain, the UK, and the US) participated in the session on tube integrity. These individuals represented utilities, vendors, consultants and regulatory authorities. The major subjects discussed by the group included overall objectives of managing steam generator tube degradation, necessary elements of a steam generator degradation management program, the concept of degradation specific management, structural integrity evaluations, leakage evaluations, and specific degradation mechanisms. The group`s discussions on these subjects, including conclusions and recommendations, are summarized in this article.

  1. Session: Long Valley Exploratory Well

    Energy Technology Data Exchange (ETDEWEB)

    Tennyson, George P. Jr.; Finger, John T.; Eichelberger, John C.; Hickox, Charles E.

    1992-01-01

    This session at the Geothermal Energy Program Review X: Geothermal Energy and the Utility Market consisted of four presentations: ''Long Valley Exploratory Well - Summary'' by George P. Tennyson, Jr.; ''The Long Valley Well - Phase II Operations'' by John T. Finger; ''Geologic results from the Long Valley Exploratory Well'' by John C. Eichelberger; and ''A Model for Large-Scale Thermal Convection in the Long Valley Geothermal Region'' by Charles E. Hickox.

  2. Semantic Session Analysis for Web Usage Mining

    Institute of Scientific and Technical Information of China (English)

    ZHANG Hui; SONG Hantao; XU Xiaomei

    2007-01-01

    A semantic session analysis method partitioning Web usage logs is presented. Semantic Web usage log preparation model enhances usage logs with semantic. The Markov chain model based on ontology semantic measurement is used to identifying which active session a request should belong to. The competitive method is applied to determine the end of the sessions.Compared with other algorithms, more successful sessions are additionally detected by semantic outlier analysis.

  3. Code-switching across brainstorming sessions: implications for the revised hierarchical model of bilingual language processing.

    Science.gov (United States)

    Blot, Kevin J; Zárate, Michael A; Paulus, Paul B

    2003-01-01

    The revised hierarchical model (RHM) of bilingual language processing posits independent word form representations for the dominant language (L1) and the nondominant language (L2), facilitated translation from L2 words to L1 words, access to common concepts for L1 and L2, and stronger activation of concepts for L1 than for L2. Spanish-English and English-Spanish bilinguals brainstormed for two sessions; half switched languages (L1-L2 or L2-L1) and half stayed in the same language (L1-L1 or L2-L2) across sessions. In both sessions, L1 brainstorming resulted in more efficient idea productivity than L2 brainstorming, supporting stronger concept activation for L1, consistent with the RHM. Switching languages from L2 to L1 resulted in the most efficient idea productivity in Session 2, suggesting that switching to L1 not only permits strong concept activation, but also the activation of concepts that are relatively different than those activated by L2, inconsistent with the RHM. Switching languages increased the proportion of Session 1 ideas repeated during Session 2, despite instructions not to repeat. This finding suggests that there is activation of concepts as well as word forms in same language brainstorming and that this dual activation aids in following instructions not to repeat, consistent with the RHM. It is suggested that the RHM be re-specified to accommodate the notion that L1 and L2 access relatively different concepts.

  4. Endicott College at 2014 TREC Session Track

    Science.gov (United States)

    2014-11-01

    the currentquery. For RL2 and RL3, we used real clicks in sessions with at least one click , and simulated clicks as the top retrieved baseline result...baseline), post spam removal. For the ECxSRMxOS RL2, we used real clicks in sessions with at least one click , and the baseline in clickless sessions. RL3

  5. Summer Session Organizational Models at Canadian Universities

    Science.gov (United States)

    Kops, Bill

    2010-01-01

    The issue of summer session organizational models continues to be of interest to summer session deans/directors and university administrators. The University of Victoria surveyed Canadian universities on this issue in 1994. Based on a similar survey done in 2009, this paper updates the status of Canadian university summer session organizational…

  6. Working session 1: Tubing degradation

    Energy Technology Data Exchange (ETDEWEB)

    Kharshafdjian, G. [Atomic Energy of Canada, Mississauga, Ontario (Canada); Turluer, G. [IPSN, Fontenay-aux-Roses (France)

    1997-02-01

    A general introductory overview of the purpose of the group and the general subject area of SG tubing degradation was given by the facilitator. The purpose of the session was described as to {open_quotes}develop conclusions and proposals on regulatory and technical needs required to deal with the issues of SG tubing degradation.{close_quotes} Types, locations and characteristics of tubing degradation in steam generators were briefly reviewed. The well-known synergistic effects of materials, environment, and stress and strain/strain rate, subsequently referred to by the acronym {open_quotes}MESS{close_quotes} by some of the group members, were noted. The element of time (i.e., evolution of these variables with time) was emphasized. It was also suggested that the group might want to consider the related topics of inspection capabilities, operational variables, degradation remedies, and validity of test data, and some background information in these areas was provided. The presentation given by Peter Millet during the Plenary Session was reviewed; Specifically, the chemical aspects and the degradation from the secondary side of the steam generator were noted. The main issues discussed during the October 1995 EPRI meeting on secondary side corrosion were reported, and a listing of the potential SG tube degradations was provided and discussed.

  7. Comparison of sonoelastography guided biopsy with systematic biopsy: impact on prostate cancer detection

    Energy Technology Data Exchange (ETDEWEB)

    Pallwein, Leo; Struve, Peter; Aigner, Friedrich; Gradl, Johann; Schurich, Matthias; Frauscher, Ferdinand [Medical University Innsbruck, Department of Radiology 2/Uroradiology, Innsbruck (Austria); Mitterberger, Michael; Horninger, Wolfgang; Bartsch, Georg [Medical University Innsbruck, Department of Urology, Innsbruck (Austria); Pedross, Florian [Medical Universit Innsbruck, Department of Medical Statistics, Information and Health Economics, Innsbruck (Austria)

    2007-09-15

    A prospective study was performed to determine the value of sonoelastography (SE) targeted biopsy for prostate cancer (PCa) detection. A series of 230 male screening volunteers was examined. Two independent examiners evaluated each subject. One single investigator performed {<=}5 SE targeted biopsies into suspicious regions in the peripheral zone only. The stiffness of the lesion was displayed by SE and color-coded from red (soft) to blue (hard). Hard lesions were considered as malignant and targeted by biopsy. Subsequently, another examiner performed ten systematic biopsies. Cancer detection rates of the two techniques were compared. Cancer was detected in 81 of the 230 patients (35%), including 68 (30%) by SE targeted biopsy and in 58 (25%) by systematic biopsy. Cancer was detected by targeted biopsy alone in 23 patients (10%) and by systematic biopsy alone in 13 patients (6%). The detection rate for SE targeted biopsy cores (12.7% or 135 of 1,109 cores) was significantly better than for systematic biopsy cores (5.6% or 130 of 2,300 cores, P < 0.001). SE targeted biopsy in a patient with cancer was 2.9-fold more likely to detect PCa than systematic biopsy. SE targeted biopsy detected more cases of PCa than systematic biopsy, with fewer than half the number of biopsy cores in this prostate-specific antigen screening population. (orig.)

  8. Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid

    Science.gov (United States)

    ... Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid An ultrasound-guided thyroid biopsy uses sound waves ... Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? During a fine needle aspiration biopsy of the ...

  9. Quantum repeated games revisited

    CERN Document Server

    Frackiewicz, Piotr

    2011-01-01

    We present a scheme for playing quantum repeated 2x2 games based on the Marinatto and Weber's approach to quantum games. As a potential application, we study twice repeated Prisoner's Dilemma game. We show that results not available in classical game can be obtained when the game is played in the quantum way. Before we present our idea, we comment on the previous scheme of playing quantum repeated games.

  10. Secure Execution of Distributed Session Programs

    CERN Document Server

    Alves, Nuno; Yoshida, Nobuko; Deniélou, Pierre-Malo; 10.4204/EPTCS.69.1

    2011-01-01

    The development of the SJ Framework for session-based distributed programming is part of recent and ongoing research into integrating session types and practical, real-world programming languages. SJ programs featuring session types (protocols) are statically checked by the SJ compiler to verify the key property of communication safety, meaning that parties engaged in a session only communicate messages, including higher-order communications via session delegation, that are compatible with the message types expected by the recipient. This paper presents current work on security aspects of the SJ Framework. Firstly, we discuss our implementation experience from improving the SJ Runtime platform with security measures to protect and augment communication safety at runtime. We implement a transport component for secure session execution that uses a modified TLS connection with authentication based on the Secure Remote Password (SRP) protocol. The key technical point is the delicate treatment of secure session de...

  11. Session Two Outcome of the Formula First Session Task in Problem- and Solution-Focused Approaches.

    Science.gov (United States)

    Jordan, Karin; Quinn, William H.

    1994-01-01

    Evaluated treatment effects in single session process using problem-focused approach and solution-focused approach. Findings indicated significant difference between two approaches when dealing with client's perceived problem improvement, outcome expectancy, session depth, session smoothness, and session positivity. Found no significant…

  12. Muscle biopsy in Pompe disease

    Directory of Open Access Journals (Sweden)

    Lineu Cesar Werneck

    2013-05-01

    Full Text Available Pompe disease (PD can be diagnosed by measuring alpha-glucosidase levels or by identifying mutations in the gene enzyme. Muscle biopsies can aid diagnosis in doubtful cases. Methods: A review of muscle biopsy from 19 cases of PD (infantile, 6 cases; childhood, 4 cases; and juvenile/adult, 9 cases. Results: Vacuoles with or without glycogen storage were found in 18 cases. All cases had increased acid phosphatase activity. The vacuole frequency varied (almost all fibers in the infantile form to only a few in the juvenile/adult form. Atrophy of type 1 and 2 fibers was frequent in all forms. Atrophic angular fibers in the NADH-tetrazolium reductase and nonspecific esterase activity were observed in 4/9 of the juvenile/adult cases. Conclusion: Increased acid phosphatase activity and vacuoles were the primary findings. Most vacuoles were filled with glycogen, and the adult form of the disease had fewer fibers with vacuoles than the infantile or childhood forms.

  13. Working session 2: Tubing inspection

    Energy Technology Data Exchange (ETDEWEB)

    Guerra, J. [Tecnatom, S.A. San Sebastian de los Reyes, Madrid (Spain); Tapping, R.L. [AECL, Chalk River, Ontario (Canada)

    1997-02-01

    This session was attended by delegates from 10 countries, and four papers were presented. A wide range of issues was tabled for discussion. Realizing that there was limited time available for more detailed discussion, three topics were chosen for the more detailed discussion: circumferential cracking, performance demonstration (to focus on POD and sizing), and limits of methods. Two other subsessions were organized: one dealt with some challenges related to the robustness of current inspection methods, especially with respect to leaving cracked tubes in service, and the other with developing a chart of current NDE technology with recommendations for future development. These three areas are summarized in turn, along with conclusions and/or recommendations. During the discussions there were four presentations. There were two (Canada, Japan) on eddy current probe developments, both of which addressed multiarray probes that would detect a range of flaws, one (Spain) on circumferential crack detection, and one (JRC, Petten) on the recent PISC III results.

  14. Kidney Biopsy: An Experience from Tertiary Hospital.

    Science.gov (United States)

    Ghimire, Madhav; Pahari, Bishnu; Paudel, Navaraj; Das, Gayatri; Das, Gopal Chandra; Sharma, Sanjib Kumar

    2014-01-01

    Kidney Biopsy is an important diagnostic tool in Nephrology. It is useful in Nephrology in terms of diagnosis, prognosis and management. There is little information on renal biopsy data from central Nepal. We describe our center`s experience in kidney biopsy in term of histological patterns, complications and outcomes. We prospectively analyzed the biopsies data of patients over a period of one and half year. All kinds of kidney disease patients were included for kidney biopsy, irrespective of their clinical syndromes and underlying diagnosis. A total of 75 biopsies were analyzed. Majority of them were females; 42 (56%). Most of the biopsies; 63 (84%) were from younger subjects ≤ 45 years and majority of them fell in the age group 11-20 years. Most common clinical renal syndrome to undergo biopsy was Sub Nephrotic range Proteinuria in 40 (53.3%). Among comorbid conditions, 40 (53.3%) had Hypertension. The most common histological pattern seen was Mesangial proliferative Glomerulonephritis seen in 18 (24%). Among complications associated with the procedure, macroscopic hematuria was seen in 5 (6.7%) cases and clinically significant perinephric hematoma causing pain was seen in 4 (5.3%). There was no mortality associated with biopsy procedure. Sub Nephrotic range Proteinuria was the commonest clinical renal Syndrome observed. In terms of renal histology, Mesangial Proliferative Glomerulonephritis (MesPGN) was the commonest histological pattern observed. Kidney biopsy is a safe procedure without any significant adverse events.

  15. Current status of transrectal ultrasound-guided prostate biopsy in the diagnosis of prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Raja, J. [Department of Radiology, St George' s Hospital, Tooting, London (United Kingdom)]. E-mail: jowadraja@gmail.com; Ramachandran, N. [Department of Radiology, St George' s Hospital, Tooting, London (United Kingdom); Munneke, G. [Department of Radiology, St George' s Hospital, Tooting, London (United Kingdom); Patel, U. [Department of Radiology, St George' s Hospital, Tooting, London (United Kingdom)

    2006-02-15

    In contemporary practice, most prostate cancers are either invisible on ultrasound or indistinguishable from concurrent benign prostatic hyperplasia. Diagnosis therefore rests on prostate biopsy. Biopsies are not simply directed at ultrasonically visible lesions, as these would miss many cancers; rather the whole gland is sampled. The sampling itself is systematic, using patterns based on prostate zonal anatomy and the geographical distribution and frequency of cancer. This review explains the evolution of the prostate biopsy technique, from the classical sextant biopsy method to the more recent extended biopsy protocols (8, 10, 12, >12 and saturation biopsy protocols). Extended protocols are increasingly being used to improve diagnostic accuracy, especially in those patients who require repeat biopsy. This trend has been facilitated by the ongoing improvement in safety and acceptability of the procedure, particularly with the use of antibiotic prophylaxis and local anaesthesia. The technical details of these extended protocols are discussed, as are the current data regarding procedure-related morbidity and how this may be minimized.

  16. Electronomicroscopic evaluation of the microlesional aspects in the pulp dentinal complex after repeated whitening therapy

    Science.gov (United States)

    Bodea, Rodica; Jianu, Rodica; Marchese, Cristian; Vasile, Liliana

    2012-06-01

    The aim of this study was to examine cellular and matriceal dynamics within pulp tissue of the teeth with repeated bleaching. Material and method - The study was made on 25 patients aged between 15 and 45, to whom bleaching method of the premolars with indication of extraction in orthodontic purposes was applied. None of the subjects smoked and throughout the investigation no antibiotics had been used. We initiated an intensive oral hygiene program, and we removed the supragingival and subgingival deposits. Oral hygiene and the gingival health were evaluated before every session of bleaching. During each visit the dentition was cleaned professionally and if needed the subjects were reinstucted in proper oral hygiene. After 3 and 5 successive bleachings of the teeth, we removed the dental pulps and we extracted the premolars. The pulpal biopsies were fixed in buffed formaldehyde 10% for 48 hours, then paraffinized, sectioned at 3-5 μ and stained with topographic, H&E and trichrome stained. For the electonomicroscopic study we used the Lehner technique to process the biopsies (n=3) after the reinclusion of the pieces from the paraffine blocks in Epon, postfixated in buffered glutaraldehyde, micro sectioned at 0,5 μ, contrastated with Pb citrate (stained) and examination in transmission electronic microscopy with Philips microscope. Results - At cellular and matriceal level we observed a marked collagen fibrillogenesis in the presence of active fibroblasts, with well developed cellular organites and fibroclastic aspects which suggest matriceal active repair. The microvascular network presents an activated endothelium with turgescent endothelial cells, with intracitoplasmatic resorbtion vacuols, well developed Golgi Complex. Conclusion - We interpreed the cell - matriceal lesions in the context of the acute inflammatory process in the first lesional phase and chronic scleroatrophic process after successive bleaching.

  17. Thyroid fine-needle aspiration biopsy and thyroid cancer diagnosis: a nationwide population-based study.

    Directory of Open Access Journals (Sweden)

    Li-Ying Huang

    Full Text Available Thyroid cancer is the most common endocrine gland malignancy and fine-needle aspiration biopsy is widely used for thyroid nodule evaluation. Repeated aspiration biopsies are needed due to plausible false-negative results. This study aimed to investigate the overall relationship between aspiration biopsy and thyroid cancer diagnosis, and to explore factors related to shorter diagnostic time.This nationwide retrospective cohort study retrieved data from the Longitudinal Health Insurance Database in Taiwan. Subjects without known thyroid malignancies and who received the first thyroid aspiration biopsy after 2004 were followed-up from 2004 to 2009 (n = 7700. Chi-square test, Kaplan-Meier survival analysis, and Cox proportional hazards model were used for data analysis.Of 7700 newly-aspirated patients, 276 eventually developed thyroid cancer (malignancy rate 3.6%. Among the 276 patients with thyroid cancer, 61.6% underwent only one aspiration biopsy and 81.2% were found within the first year after the initial aspiration. Cox proportional hazards model revealed that aspiration frequency (HR 1.07, 95% CI 1.06-1.08, ultrasound frequency (HR 1.02, 95% CI 1.01-1.03, older age, male sex, and aspiration biopsies arranged by surgery, endocrinology or otolaryngology subspecialties were all associated with shorter time to thyroid cancer diagnosis.About 17.4% of thyroid cancer cases received more than two aspiration biopsies and 18.8% were diagnosed one year after the first biopsy. Regular follow-up with repeated aspiration or ultrasound may be required for patients with clinically significant thyroid nodules.

  18. Stereotactic breast biopsy: pitfalls and pearls.

    Science.gov (United States)

    Huang, Monica L; Adrada, Beatriz E; Candelaria, Rosalind; Thames, Deborah; Dawson, Debora; Yang, Wei T

    2014-03-01

    Stereotactic breast biopsies have become indispensable and the standard of care for patients in whom screening mammography or tomosynthesis reveals breast lesions suggestive of malignancy. A variety of stereotactic biopsy systems and needle types are now available, which allow more accurate sampling of lesions as well as successful biopsy of lesions in difficult locations in patients of all body habitus. We discuss how to plan, perform, and follow up stereotactic biopsies. Most importantly, we offer suggestions on how to avoid problems and complications and detail how to achieve technical success even in the most challenging cases. Stereotactic biopsy has proven over time to be an accurate and acceptable alternative to surgical biopsy for histopathologic diagnosis of breast abnormalities. Successful performance of this minimally invasive procedure spares women from undergoing potentially deforming and expensive procedures to diagnose breast disease.

  19. Repeated Witnessing of Conspecifics in Pain: Effects on Emotional Contagion.

    Directory of Open Access Journals (Sweden)

    Maria Carrillo

    Full Text Available Witnessing of conspecifics in pain has been shown to elicit socially triggered freezing in rodents. It is unknown how robust this response is to repeated exposure to a cage-mate experiencing painful stimulation. To address this question, shock-experienced Observer rats repeatedly witnessed familiar Demonstrators receive painful footshocks (six sessions. Results confirm that Observers freeze during the first testing session. The occurrence of this behaviour however gradually diminished as the experimental sessions progressed, reaching minimal freezing levels by the end of the experiments. In contrast, the appearance and continuous increase in the frequency of yawning, a behavior that was inhibited by metyrapone (i.e,. a glucocorticoid synthesis blocker, might represent an alternative coping strategy, suggesting that the observer's reduced freezing does not necessarily indicate a disappearance in the affective response to the Demonstrator's distress.

  20. Photoacoustic biopsy: a feasibility study

    Science.gov (United States)

    Xu, Guan; Tomlins, Scott A.; Siddiqui, Javed; Davis, Mandy A.; Kunju, Lakshmi P.; Wei, John T.; Wang, Xueding

    2015-03-01

    Photoacoustic (PA) measurements encode the information associated with both physical microstructures and chemical contents in biological tissues. A two-dimensional physio-chemical spectrogram (PCS) can be formulated by combining the power spectra of PA signals acquired at a series of optical wavelengths. The analysis of PCS, or namely PA physio-chemical analysis (PAPCA), enables the quantification of the concentrations and the spatial distributions of a variety of chemical components in the tissue. The chemical components and their distribution are the two major features observed in the biopsy procedures which have been regarded as the gold standard of the diagnosis of many diseases. Taking non-alcoholic fatty liver disease and prostate cancer for example, this study investigates the feasibility of PAPCA in characterizing the histopathological changes in the diseased conditions in biological tissue. A catheter based setup facilitating measurement in deep tissues was also proposed and tested.

  1. Comparison of sonoelastography guided biopsy with systematic biopsy: impact on prostate cancer detection.

    Science.gov (United States)

    Pallwein, Leo; Mitterberger, Michael; Struve, Peter; Horninger, Wolfgang; Aigner, Friedrich; Bartsch, Georg; Gradl, Johann; Schurich, Matthias; Pedross, Florian; Frauscher, Ferdinand

    2007-09-01

    A prospective study was performed to determine the value of sonoelastography (SE) targeted biopsy for prostate cancer (PCa) detection. A series of 230 male screening volunteers was examined. Two independent examiners evaluated each subject. One single investigator performed stiffness of the lesion was displayed by SE and color-coded from red (soft) to blue (hard). Hard lesions were considered as malignant and targeted by biopsy. Subsequently, another examiner performed ten systematic biopsies. Cancer detection rates of the two techniques were compared. Cancer was detected in 81 of the 230 patients (35%), including 68 (30%) by SE targeted biopsy and in 58 (25%) by systematic biopsy. Cancer was detected by targeted biopsy alone in 23 patients (10%) and by systematic biopsy alone in 13 patients (6%). The detection rate for SE targeted biopsy cores (12.7% or 135 of 1,109 cores) was significantly better than for systematic biopsy cores (5.6% or 130 of 2,300 cores, P cancer was 2.9-fold more likely to detect PCa than systematic biopsy. SE targeted biopsy detected more cases of PCa than systematic biopsy, with fewer than half the number of biopsy cores in this prostate-specific antigen screening population.

  2. Nerve Biopsy In The Diagnosis Of Leporsy

    Directory of Open Access Journals (Sweden)

    Hazra B

    1997-01-01

    Full Text Available Skin and nerve biopsies were done in 33 cases of different clinical types of leprosy selected from Dermatology OPD of Medical College and Hospitals, Calcutta during 1994-95. Histopathological results were compared with emphasis on the role of nerve biopsies in detection of patients with multibacillary leprosy. The evident possibility of having patients with multibacillary leprosy in peripheral leprosy with multiple drugs. It is found that skin and nerve biopsy are equally informative in borderline and lepromatour leprosy and is the only means to diagnose polyneuritic leprosy. Nerve biopsy appears to be more informative in the diagnosis of all clinical types of leprosy.

  3. Needle muscle biopsy and its application

    Directory of Open Access Journals (Sweden)

    Meng-long CHEN

    2015-07-01

    Full Text Available Needle muscle biopsy is a straightforward and reliable minimally-invasive technique. During the past century, the needle biopsy can provide adequate samples and the technique has gradually gained wider acceptance. Compared with open biopsy, needle biopsy is less traumatic, with low rate of complications, and is suitable for the identifications and evaluations of muscular dystrophy, inflammatory myopathies and systemic diseases involving muscles, specially for infants and young children. Domestic insiders should be encouraged to apply this technique. DOI: 10.3969/j.issn.1672-6731.2015.06.003 

  4. Surface staining of small intestinal biopsies

    DEFF Research Database (Denmark)

    Poulsen, Steen Seier

    1977-01-01

    Small intestinal biopsies are most often by routine examined under a stereo-microscope, prior to embedding for histological examination. This is done in order to get a view of the appearance of the mucosal pattern, especially villus configuration. The distinctness of the surface pattern however......, is improved considerably if the biopsies are stained with Alcian Green and/or PAS before they are examined. In the present paper a detailed description is given of staining of small intestinal biopsies as whole mounts. The difference between the unstained and the stained biopsies is illustrated by a few...

  5. Hypoxic Repeat Sprint Training Improves Rugby Player's Repeated Sprint but Not Endurance Performance.

    Science.gov (United States)

    Hamlin, Michael J; Olsen, Peter D; Marshall, Helen C; Lizamore, Catherine A; Elliot, Catherine A

    2017-01-01

    This study aims to investigate the performance changes in 19 well-trained male rugby players after repeat-sprint training (six sessions of four sets of 5 × 5 s sprints with 25 s and 5 min of active recovery between reps and sets, respectively) in either normobaric hypoxia (HYP; n = 9; FIO2 = 14.5%) or normobaric normoxia (NORM; n = 10; FIO2 = 20.9%). Three weeks after the intervention, 2 additional repeat-sprint training sessions in hypoxia (FIO2 = 14.5%) was investigated in both groups to gauge the efficacy of using "top-up" sessions for previously hypoxic-trained subjects and whether a small hypoxic dose would be beneficial for the previously normoxic-trained group. Repeated sprint (8 × 20 m) and Yo-Yo Intermittent Recovery Level 1 (YYIR1) performances were tested twice at baseline (Pre 1 and Pre 2) and weekly after (Post 1-3) the initial intervention (intervention 1) and again weekly after the second "top-up" intervention (Post 4-5). After each training set, heart rate, oxygen saturation, and rate of perceived exertion were recorded. Compared to baseline (mean of Pre 1 and Pre 2), both the hypoxic and normoxic groups similarly lowered fatigue over the 8 sprints 1 week after the intervention (Post 1: -1.8 ± 1.6%, -1.5 ± 1.4%, mean change ± 90% CI in HYP and NORM groups, respectively). However, from Post 2 onwards, only the hypoxic group maintained the performance improvement compared to baseline (Post 2: -2.1 ± 1.8%, Post 3: -2.3 ± 1.7%, Post 4: -1.9 ± 1.8%, and Post 5: -1.2 ± 1.7%). Compared to the normoxic group, the hypoxic group was likely to have substantially less fatigue at Post 3-5 (-2.0 ± 2.4%, -2.2 ± 2.4%, -1.6 ± 2.4% Post 3, Post 4, Post 5, respectively). YYIR1 performances improved throughout the recovery period in both groups (13-37% compared to baseline) with unclear differences found between groups. The addition of two sessions of "top-up" training after intervention 1, had little effect on either group. Repeat-sprint training in

  6. Hypoxic Repeat Sprint Training Improves Rugby Player's Repeated Sprint but Not Endurance Performance

    Science.gov (United States)

    Hamlin, Michael J.; Olsen, Peter D.; Marshall, Helen C.; Lizamore, Catherine A.; Elliot, Catherine A.

    2017-01-01

    This study aims to investigate the performance changes in 19 well-trained male rugby players after repeat-sprint training (six sessions of four sets of 5 × 5 s sprints with 25 s and 5 min of active recovery between reps and sets, respectively) in either normobaric hypoxia (HYP; n = 9; FIO2 = 14.5%) or normobaric normoxia (NORM; n = 10; FIO2 = 20.9%). Three weeks after the intervention, 2 additional repeat-sprint training sessions in hypoxia (FIO2 = 14.5%) was investigated in both groups to gauge the efficacy of using “top-up” sessions for previously hypoxic-trained subjects and whether a small hypoxic dose would be beneficial for the previously normoxic-trained group. Repeated sprint (8 × 20 m) and Yo-Yo Intermittent Recovery Level 1 (YYIR1) performances were tested twice at baseline (Pre 1 and Pre 2) and weekly after (Post 1–3) the initial intervention (intervention 1) and again weekly after the second “top-up” intervention (Post 4–5). After each training set, heart rate, oxygen saturation, and rate of perceived exertion were recorded. Compared to baseline (mean of Pre 1 and Pre 2), both the hypoxic and normoxic groups similarly lowered fatigue over the 8 sprints 1 week after the intervention (Post 1: −1.8 ± 1.6%, −1.5 ± 1.4%, mean change ± 90% CI in HYP and NORM groups, respectively). However, from Post 2 onwards, only the hypoxic group maintained the performance improvement compared to baseline (Post 2: −2.1 ± 1.8%, Post 3: −2.3 ± 1.7%, Post 4: −1.9 ± 1.8%, and Post 5: −1.2 ± 1.7%). Compared to the normoxic group, the hypoxic group was likely to have substantially less fatigue at Post 3–5 (−2.0 ± 2.4%, −2.2 ± 2.4%, −1.6 ± 2.4% Post 3, Post 4, Post 5, respectively). YYIR1 performances improved throughout the recovery period in both groups (13–37% compared to baseline) with unclear differences found between groups. The addition of two sessions of “top-up” training after intervention 1, had little effect on either

  7. Flexible Session Management in a Distributed Environment

    CERN Document Server

    Miller, Zach; Tannenbaum, Todd; Sfiligoi, Igor

    2010-01-01

    Many secure communication libraries used by distributed systems, such as SSL, TLS, and Kerberos, fail to make a clear distinction between the authentication, session, and communication layers. In this paper we introduce CEDAR, the secure communication library used by the Condor High Throughput Computing software, and present the advantages to a distributed computing system resulting from CEDAR's separation of these layers. Regardless of the authentication method used, CEDAR establishes a secure session key, which has the flexibility to be used for multiple capabilities. We demonstrate how a layered approach to security sessions can avoid round-trips and latency inherent in network authentication. The creation of a distinct session management layer allows for optimizations to improve scalability by way of delegating sessions to other components in the system. This session delegation creates a chain of trust that reduces the overhead of establishing secure connections and enables centralized enforcement of syst...

  8. Reconfigurable multiport EPON repeater

    Science.gov (United States)

    Oishi, Masayuki; Inohara, Ryo; Agata, Akira; Horiuchi, Yukio

    2009-11-01

    An extended reach EPON repeater is one of the solutions to effectively expand FTTH service areas. In this paper, we propose a reconfigurable multi-port EPON repeater for effective accommodation of multiple ODNs with a single OLT line card. The proposed repeater, which has multi-ports in both OLT and ODN sides, consists of TRs, BTRs with the CDR function and a reconfigurable electrical matrix switch, can accommodate multiple ODNs to a single OLT line card by controlling the connection of the matrix switch. Although conventional EPON repeaters require full OLT line cards to accommodate subscribers from the initial installation stage, the proposed repeater can dramatically reduce the number of required line cards especially when the number of subscribers is less than a half of the maximum registerable users per OLT. Numerical calculation results show that the extended reach EPON system with the proposed EPON repeater can save 17.5% of the initial installation cost compared with a conventional repeater, and can be less expensive than conventional systems up to the maximum subscribers especially when the percentage of ODNs in lightly-populated areas is higher.

  9. Revisiting the TALE repeat.

    Science.gov (United States)

    Deng, Dong; Yan, Chuangye; Wu, Jianping; Pan, Xiaojing; Yan, Nieng

    2014-04-01

    Transcription activator-like (TAL) effectors specifically bind to double stranded (ds) DNA through a central domain of tandem repeats. Each TAL effector (TALE) repeat comprises 33-35 amino acids and recognizes one specific DNA base through a highly variable residue at a fixed position in the repeat. Structural studies have revealed the molecular basis of DNA recognition by TALE repeats. Examination of the overall structure reveals that the basic building block of TALE protein, namely a helical hairpin, is one-helix shifted from the previously defined TALE motif. Here we wish to suggest a structure-based re-demarcation of the TALE repeat which starts with the residues that bind to the DNA backbone phosphate and concludes with the base-recognition hyper-variable residue. This new numbering system is consistent with the α-solenoid superfamily to which TALE belongs, and reflects the structural integrity of TAL effectors. In addition, it confers integral number of TALE repeats that matches the number of bound DNA bases. We then present fifteen crystal structures of engineered dHax3 variants in complex with target DNA molecules, which elucidate the structural basis for the recognition of bases adenine (A) and guanine (G) by reported or uncharacterized TALE codes. Finally, we analyzed the sequence-structure correlation of the amino acid residues within a TALE repeat. The structural analyses reported here may advance the mechanistic understanding of TALE proteins and facilitate the design of TALEN with improved affinity and specificity.

  10. One-Session Exposure Treatment for Social Anxiety with Specific Fear of Public Speaking

    Science.gov (United States)

    Hindo, Cindy S.; Gonzalez-Prendes, A. Antonio

    2011-01-01

    Objectives: This pilot study evaluated the effectiveness of one-session, exposure-based therapy, to treat social anxiety disorder (SAD) with specific fear of public speaking. Methods: A quasi-experimental pre-posttest design with repeated measures-within-subject Analysis of Variance and paired sample t-tests was used to compare pretest, posttest…

  11. One-Session Exposure Treatment for Social Anxiety with Specific Fear of Public Speaking

    Science.gov (United States)

    Hindo, Cindy S.; Gonzalez-Prendes, A. Antonio

    2011-01-01

    Objectives: This pilot study evaluated the effectiveness of one-session, exposure-based therapy, to treat social anxiety disorder (SAD) with specific fear of public speaking. Methods: A quasi-experimental pre-posttest design with repeated measures-within-subject Analysis of Variance and paired sample t-tests was used to compare pretest, posttest…

  12. Control DHT maintenance costs with session heterogeneity

    Institute of Scientific and Technical Information of China (English)

    ZOU Fu-tai; WU Zeng-de; ZHANG Liang; MA Fan-yuan

    2005-01-01

    The maintaining overheads of Distributed Hash Table (DHT) topology have recently received considerable attention.This paper presents a novel SHT (Session Heterogeneity Topology) model, in which DHT is reconstructed with session heterogeneity. SHT clusters nodes by means of session heterogeneity among nodes and selects the stable nodes as the participants of DHT. With an evolving process, this model gradually makes DHT stable and reliable. Therefore the high maintaining overheads for DHT are effectively controlled. Simulation with real traces of session distribution showed that the maintaining overheads are reduced dramatically and that the data availability is greatly improved.

  13. Renal mass biopsy--a renaissance?

    Science.gov (United States)

    Lane, Brian R; Samplaski, Mary K; Herts, Brian R; Zhou, Ming; Novick, Andrew C; Campbell, Steven C

    2008-01-01

    Advances in our understanding of the natural history and limited aggressive potential of many small renal masses, expanding treatment options and the integration of molecular factors into prognostic and therapeutic algorithms have stimulated renewed interest in percutaneous renal mass biopsy. A comprehensive literature review was performed using MEDLINE/PubMed to evaluate the indications, techniques, complications and efficacy of renal mass biopsy. Reported techniques of renal mass biopsy vary widely with different modes of radiographic guidance, needle size, number of cores and pathological analyses. Percutaneous renal mass biopsy with 2 or 3 cores using 18 gauge needles may improve diagnostic accuracy without increasing morbidity. Serious complications of percutaneous biopsy are rare and the minor complication rate in recent series has been less than 5%. The reported rate of technical failure of renal mass biopsy due to insufficient material was about 9% before 2001 and 5% in more recent studies. The likelihood of indeterminate or inaccurate pathological findings has decreased from 10% to 4% when comparing clinical studies before and since 2001. Currently a total success rate of greater than 90% is attainable using renal mass biopsy with standard histopathological analysis. Recent studies demonstrated that combining immunohistochemical and molecular analyses may further improve renal mass biopsy accuracy. Research on expanded analysis of percutaneous renal mass biopsy specimens should remain a top priority. Enhanced renal mass biopsy should not change treatment in most patients with small renal masses, who should be treated with surgical excision. However, future clinical algorithms will likely incorporate enhanced biopsy in situations in which decision making is more challenging.

  14. The Physics session at the ATLAS overview week

    CERN Multimedia

    Takai, H.

    The Physics session at the ATLAS overview week at Clermont-Ferrand will be certainly remembered by the presentation of Blaise Pascal's historical experiment repeat. And why not? He is the local hero and by the looks of his primitive measurements it does take a lot of guts to explain his results on the basis of air columns. He was also lucky that he did not have to simulate his results on modern day computers but used the Pascaline. Certainly a man ahead of his time. Of course that wasn't all. Surrounded by a chain of (luckily) extinct volcanoes, rolling hills, and superb views, Clermont-Ferrand provided the perfect backdrop for the physics discussions. It was once more seen that the physics of ATLAS is diverse and that it is healthy and doing well. Many people contributed to the success of the session. Fabiola started the session precisely at 14:00 with a summary of the most recent activities from the physics coordination. Somehow what got stuck in my mind was the very positive statistics on how many prese...

  15. Effects of an Intensive Resistant Training Sessions and Green Tea

    Directory of Open Access Journals (Sweden)

    Mohammad Esmaeil Afzalpour

    2014-03-01

    Full Text Available Background: Intensive and acute exercise trainings may induce oxidative stress, but antioxidant supplements may attenuate its degenerative consequences. The aim of this research was to examine the effect of green tea supplementation on the oxidative stress indices after an intensive resistance training session. Materials and Methods: 40 non-athletes (without regular physical activity women were randomly divided into 4 equal (n=10 groups including green tea supplementation, green tea supplementation plus resistance training, resistance training, and control groups. After supplementation period (600 mg/day, 14 days, resistance training and green tea supplementation plus resistance training groups performed an intensive resistance training session at 75-85 % of one repetition maximum. The malondialdehyde and total thiol were measured as oxidative stress indices. Data were analyzed by using of repeated measure ANOVA and LSD tests at p<0.056T. Results: Results showed that after 14 days of green tea consumption, malondialdehyde significantly decreased in green tea supplementation (p=0.03 and green tea supplementation plus resistance training (p=0.01 groups, while total thiol increased significantly (p=0.01 in two green tea supplementation groups. However, an intensive resistance training session increased malondialdehyde (p=0.01 without any significantly changes in total thiol (p=0.426T. Conclusion: It seems that green tea supplementation can inhibit exercise-induced protein and lipid oxidation in non-athletes women via enhancement of antioxidant defense system of the body6T.6T

  16. Recursive quantum repeater networks

    CERN Document Server

    Van Meter, Rodney; Horsman, Clare

    2011-01-01

    Internet-scale quantum repeater networks will be heterogeneous in physical technology, repeater functionality, and management. The classical control necessary to use the network will therefore face similar issues as Internet data transmission. Many scalability and management problems that arose during the development of the Internet might have been solved in a more uniform fashion, improving flexibility and reducing redundant engineering effort. Quantum repeater network development is currently at the stage where we risk similar duplication when separate systems are combined. We propose a unifying framework that can be used with all existing repeater designs. We introduce the notion of a Quantum Recursive Network Architecture, developed from the emerging classical concept of 'recursive networks', extending recursive mechanisms from a focus on data forwarding to a more general distributed computing request framework. Recursion abstracts independent transit networks as single relay nodes, unifies software layer...

  17. 'Microerosions' in rectal biopsies in Crohn's disease

    DEFF Research Database (Denmark)

    Poulsen, Steen Seier

    1984-01-01

    Small (less than 1 mm), superficial erosions ('microerosions') have been observed stereo-microscopically in surface-stained rectal biopsies in Crohn's disease (CD). Biopsy specimens from 97 patients with CD, 225 with ulcerative colitis (UC), and a control material of 161 patients were investigated...

  18. Pain and Anxiety During Bone Marrow Biopsy

    NARCIS (Netherlands)

    Tanasale, Betty; Kits, Jenne; Kluin, Philip M.; Trip, Albert; Kluin-Nelemans, Hanneke C.

    2013-01-01

    A bone marrow biopsy is considered to be painful, often causing anxiety. We observed large differences between patients and wondered which factors cause pain and anxiety. In a prospective study, 202 patients were analyzed. Experienced hematologists and fellows in training (17% of biopsies) performed

  19. Pain and Anxiety During Bone Marrow Biopsy

    NARCIS (Netherlands)

    Tanasale, Betty; Kits, Jenne; Kluin, Philip M.; Trip, Albert; Kluin-Nelemans, Hanneke C.

    2013-01-01

    A bone marrow biopsy is considered to be painful, often causing anxiety. We observed large differences between patients and wondered which factors cause pain and anxiety. In a prospective study, 202 patients were analyzed. Experienced hematologists and fellows in training (17% of biopsies) performed

  20. Evaluation of Stress Scores Throughout Radiological Biopsies

    Directory of Open Access Journals (Sweden)

    Turkoglu

    2016-06-01

    Full Text Available Background Ultrasound-guided biopsy procedures are the most prominent methods that increase the trauma, stress and anxiety experienced by the patients. Objectives Our goal was to examine the level of stress in patients waiting for radiologic biopsy procedures and determine the stress and anxiety level arising from waiting for a biopsy procedure. Patients and Methods This prospective study included 35 female and 65 male patients who were admitted to the interventional radiology department of Kartal Dr. Lütfi Kirdar training and research hospital, Istanbul between the years 2014 and 2015. They filled out the adult resilience scale consisting of 33 items. Patients who were undergoing invasive radiologic interventions were grouped according to their phenotypic characteristics, education level (low, intermediate, and high, and biopsy features (including biopsy localization: neck, thorax, abdomen, and bone; and the number of procedures performed, 1 or more than 1. Before the biopsy, they were also asked to complete the depression-anxiety-stress scale (DASS 42, state-trait anxiety inventory scale (STAI-I, and continuous anxiety scale STAI-II. A total of 80 patients were biopsied (20 thyroid and parathyroid, 20 thorax, 20 liver and kidney, and 20 bone biopsies. The association between education levels (primary- secondary, high school and postgraduate and the number of biopsies (1 and more than 1 with the level of anxiety and stress were evaluated using the above-mentioned scales. Results Evaluation of sociodemographic and statistical characteristics of the patients showed that patients with biopsy in the neck region were moderately and severely depressed and stressed. In addition, the ratio of severe and extremely severe anxiety scores was significantly high. While the STAI-I and II scores were lined up as neck > bone > thorax > abdomen, STAI-I was higher in neck biopsies compared to thorax and abdomen biopsies. Regarding STAI-I and II scales, patients

  1. Computed tomography-guided biopsy. I. Overview.

    Science.gov (United States)

    Haaga, J R; Reich, N E; Havrilla, T R; Alfidi, R J; Meaney, T F

    1978-03-01

    The authors are preparing a series of communications on CT-guided biopsy procedures to be published in future issues of this journal. The present article, which previously appeared in the Cleveland Clinic Quarterly, is intended to serve as an introduction to the concept of CT-guided biopsies. Because the principles of the biopsy procedure remain the same, we do not believe that a "rewrite" of the previously published article would be required. We hope that by presenting this article and subsequent articles concerning the use of CT-guided biopsies, the reader will acquire an appreciation of the proper role of this exciting new technique in comparison to the available imaging modalities. We believe that as individuals become more experienced with the imaging capabilities of these CT devices, they will want to develop the technique of obtaining biopsy confirmation of the imaging diagnosis.

  2. Delayed culture of Leishmania in skin biopsies.

    Science.gov (United States)

    Dedet, J P; Pratlong, F; Pradinaud, R; Moreau, B

    1999-01-01

    Between January 1997 and October 1998, 16 skin biopsies collected from 13 patients with cutaneous leishmaniasis in French Guiana were inoculated in culture medium after travel for 3-17 days from the place of biopsy to the culture laboratory in France. Each biopsy fragment was introduced near the flame of a Bunsen burner into the transport medium (RPMI medium supplemented with 10% fetal calf serum) which was maintained at ambient temperature during postal delivery to France. In France the biopsies were ground in sterile saline before being inoculated into NNN culture tubes. The cultures were incubated at 25 degrees C and subcultured every week until the 5th week. The cultures were positive in 9 cases, remained negative in 4, and were contaminated in 3 cases. Positive results were obtained at all seasons and for 3 different Leishmania species. The study indicates that delayed culture can yield useful results from biopsies taken in field conditions.

  3. Transjugular liver biopsy: indications, technique and results.

    Science.gov (United States)

    Dohan, A; Guerrache, Y; Boudiaf, M; Gavini, J-P; Kaci, R; Soyer, P

    2014-01-01

    Transjugular liver biopsy is a safe, effective and well-tolerated technique to obtain liver tissue specimens in patients with diffuse liver disease associated with severe coagulopathies or massive ascites. Transjugular liver biopsy is almost always feasible. The use of ultrasonographic guidance for percutaneous puncture of the right internal jugular vein is recommended to decrease the incidence of local cervical minor complications. Semiautomated biopsy devices are very effective in obtaining optimal tissue samples for a precise and definite histological diagnosis with a very low rate of complication. The relative limitations of transjugular liver biopsy are the cost, the radiation dose given to the patient, the increased procedure time by comparison with the more common percutaneous liver biopsy, and the need of a well-trained interventional radiologist.

  4. Biopsy needle detection in transrectal ultrasound.

    Science.gov (United States)

    Ayvaci, Alper; Yan, Pingkun; Xu, Sheng; Soatto, Stefano; Kruecker, Jochen

    2011-01-01

    Using the fusion of pre-operative MRI and real time intra-procedural transrectal ultrasound (TRUS) to guide prostate biopsy has been shown as a very promising approach to yield better clinical outcome than the routinely performed TRUS only guided biopsy. In several situations of the MRI/TRUS fusion guided biopsy, it is important to know the exact location of the deployed biopsy needle, which is imaged in the TRUS video. In this paper, we present a method to automatically detect and segment the biopsy needle in TRUS. To achieve this goal, we propose to combine information from multiple resources, including ultrasound probe stability, TRUS video background model, and the prior knowledge of needle orientation and position. The proposed algorithm was tested on TRUS video sequences which have in total more than 25,000 frames. The needle deployments were successfully detected and segmented in the sequences with high accuracy and low false-positive detection rate.

  5. The liquid biopsy in lung cancer.

    Science.gov (United States)

    Ansari, Junaid; Yun, Jungmi W; Kompelli, Anvesh R; Moufarrej, Youmna E; Alexander, Jonathan S; Herrera, Guillermo A; Shackelford, Rodney E

    2016-11-01

    The incidence of lung cancer has significantly increased over the last century, largely due to smoking, and remains the most common cause of cancer deaths worldwide. This is often due to lung cancer first presenting at late stages and a lack of curative therapeutic options at these later stages. Delayed diagnoses, inadequate tumor sampling, and lung cancer misdiagnoses are also not uncommon due to the limitations of the tissue biopsy. Our better understanding of the tumor microenvironment and the systemic actions of tumors, combined with the recent advent of the liquid biopsy, may allow molecular diagnostics to be done on circulating tumor markers, particularly circulating tumor DNA. Multiple liquid biopsy molecular methods are presently being examined to determine their efficacy as surrogates to the tumor tissue biopsy. This review will focus on new liquid biopsy technologies and how they may assist in lung cancer detection, diagnosis, and treatment.

  6. Efficacy and cost analysis of transrectal ultrasound-guided prostate biopsy under monitored anesthesia

    Institute of Scientific and Technical Information of China (English)

    Sung Gu Kang; Bum Sik Tae; Sam Hong Mine; Young Hwu Ko; Seok Ho Kang; Jeong Gu Lee; Je Jong Kim; Jun Cheon

    2011-01-01

    @@ Sedation may result in reduction in pain during transrectal ultrasound(TRUS)-guided prostate biopsies.We aimed to evaluate the efficacy and safety of a combination of propofol and remifentanil infusion during TRUS-guided prostate biopsy and the related increases in health care costs.From January to September 2010,100 men undergoing a transrectal prostate biopsy were randomized into two groups.In Group 1,[50]patients received a combined infusion of propofol and remifentanil; in Group 2,[50]patients received lidocaine jelly.After TRUS-guided biopsies were performed,pain and patient satisfaction were evaluated by a 10-point visual analog scale (VAS),and a cost-related patient satisfaction questionnaire was completed by all patients.Patients were also asked whether they would be willing to undergo repeat biopsy by the same method.Patients in Group 1 showed a significantly lower VAS score than those in Group 2 (mean VAS score: 0.9士1.1 versus 6.312.5; P<0.001).In addition,the patient satisfaction scale was significantly higher in Group 1(P=0.002).Although the overall cost was significantly higher in Group 1(P=0.006),patient satisfaction scales considering cost were also higher in this group (P=0.009).A combination of propofol and remifentanil is a safe and effective way to decrease patient pain and increase patient satisfaction during TRUS-guided prostate biopsy.Although the costs were higher in the group that received sedation,as expected,the patients exhibited heightened satisfaction and willingness to repeat biopsies by the same method.

  7. Ann Arbor Session I: Breaking Ground.

    Science.gov (United States)

    Music Educators Journal, 1979

    1979-01-01

    Summarizes the first session of the National Symposium on the Applications of Psychology to the Teaching and Learning of Music held at Ann Arbor from October 30 to November 2, 1978. Sessions concerned auditory perception, motor learning, child development, memory and information processing, and affect and motivation. (SJL)

  8. The International Mathematical Olympiad Training Session.

    Science.gov (United States)

    Rousseau, Cecil; Patruno, Gregg

    1985-01-01

    The Mathematical Olympiad Training Session is designed to give United States students a problem-oriented exposure to subject areas (algebra, geometry, number theory, combinatorics, and inequalities) through an intensive three-week course. Techniques used during the session, with three sample problems and their solutions, are presented. (JN)

  9. Spanning a multimedia session across multiple devices

    NARCIS (Netherlands)

    Aartse Tuijn, Jasper; Bijwaard, Dennis

    2008-01-01

    This paper describes an innovative solution that allows a multimedia session to be distributed over multiple devices that are in close proximity to a user. This would typically be useful when a user engaged in an audio/video conference enters a meeting room. Upon entering, all media session componen

  10. Multiparty Session Types as Coherence Proofs

    DEFF Research Database (Denmark)

    Carbone, Marco; Montesi, Fabrizio; Schürmann, Carsten;

    2015-01-01

    We propose a Curry-Howard correspondence between a language for programming multiparty sessions and a generalisation of Classical Linear Logic (CLL). In this framework, propositions correspond to the local behaviour of a participant in a multiparty session type, proofs to processes, and proof...

  11. A Case of Dermatomyositis with Esophageal Fistula in Whom Blind Mucosal Biopsy Detected Occult Oropharyngeal Carcinoma

    Directory of Open Access Journals (Sweden)

    Miho Kabuto

    2014-11-01

    Full Text Available We present a case of anti-transcription intermediary factor 1 (anti-TIF-1 antibody-positive dermatomyositis with concomitant esophageal fistula and extensive truncal erythema. The characteristic cutaneous features and presence of anti-TIF-1 antibodies were predictive for internal malignancy. However, repeated examinations for internal malignancy showed none, and blind mucosal biopsy was needed to diagnose oropharyngeal carcinoma. We should note the possibility of occult nasopharyngeal carcinoma and consider performing blind mucosal biopsy in dermatomyositis with esophageal fistula, especially with extensive truncal erythema.

  12. Possibility of transrectal photoacoustic imaging-guided biopsy for detection of prostate cancer

    Science.gov (United States)

    Ishihara, Miya; Shinchi, Masayuki; Horiguchi, Akio; Shinmoto, Hiroshi; Tsuda, Hitoshi; Irisawa, Kaku; Wada, Takatsugu; Asano, Tomohiko

    2017-03-01

    A transrectral ultrasonography (TRUS) guided prostate biopsy is mandatory for histological diagnosis in patients with an elevated serum prostate-specific antigen (PSA), but its diagnostic accuracy is not satisfactory; therefore, a considerable number of patients are forced to have an unnecessary repeated biopsy. Photoacoustic (PA) imaging has the ability to visualize the distribution of hemoglobin clearly. Thus, there is the potential to acquire different maps of small vessel networks between cancerous and normal tissue. We developed an original TRUS-type PA probe consisting of a microconvex array transducer with an optical illumination system providing coregistered PA and ultrasound images. The purpose of this study is to demonstrate the clinical possibility of a transrectral PA image. The prostate biopsy cores obtained by transrectal systemic biopsies under TRUS guidance were stained with HE staining and anti-CD34 antibodies as a marker of the endothelium of the blood vessel in order to find a pattern in the map of a small vessel network, which allows for imaging-based identification of prostate cancer. We analyzed the association of PA signal patterns, the cancer location by a magnetic resonance imaging (MRI) study, and the pathological diagnosis with CD34 stains as a prospective intervention study. In order to demonstrate the TRUS-merged-with-PA imaging guided targeted biopsy combined with a standard biopsy for capturing the clinically significant tumors, we developed a puncture needle guide attachment for the original TRUS-type PA probe.

  13. Omitting the intra-session calibration in EEG-based brain computer interface used for stroke rehabilitation.

    Science.gov (United States)

    Arvaneh, Mahnaz; Guan, Cuntai; Ang, Kai Keng; Quek, Chai

    2012-01-01

    Brain-computer interface (BCI) as a rehabilitation tool has been used in restoring motor functions in patients with moderate to sever stroke impairments. To achieve the best possible outcome in such an application, it is highly desirable to have a stable and accurate operation of BCI. However, since electroencephalogram (EEG) signals considerably vary between sessions of even the same user, typically a long calibration session is recorded at the beginning of each session. This process is time-consuming and inconvenient for stroke patients who undergo long-term BCI sessions with repeating same mental tasks. This paper investigates the possibility of omitting the intra-session calibration for BCI-based stroke rehabilitation when large data recorded from the same user are available. For this purpose, a large dataset of EEG signals from 11 stroke patients performing 12 BCI-based stroke rehabilitation sessions over one month is used. Our offline results suggest that after recording a number of stroke rehabilitation sessions, the patient does not require calibration any more. The experimental results show that combining 11 sessions, which each session comprises minimum 60 trials per class, yields a model that averagely outperforms the standard calibration model trained by the data recorded directly before the test session.

  14. Repeated sprint training in normobaric hypoxia.

    Science.gov (United States)

    Galvin, Harvey M; Cooke, Karl; Sumners, David P; Mileva, Katya N; Bowtell, Joanna L

    2013-12-01

    Repeated sprint ability (RSA) is a critical success factor for intermittent sport performance. Repeated sprint training has been shown to improve RSA, we hypothesised that hypoxia would augment these training adaptations. Thirty male well-trained academy rugby union and rugby league players (18.4 ± 1.5 years, 1.83 ± 0.07 m, 88.1 ± 8.9 kg) participated in this single-blind repeated sprint training study. Participants completed 12 sessions of repeated sprint training (10 × 6 s, 30 s recovery) over 4 weeks in either hypoxia (13% FiO₂) or normoxia (21% FiO₂). Pretraining and post-training, participants completed sports specific endurance and sprint field tests and a 10 × 6 s RSA test on a non-motorised treadmill while measuring speed, heart rate, capillary blood lactate, muscle and cerebral deoxygenation and respiratory measures. Yo-Yo Intermittent Recovery Level 1 test performance improved after RS training in both groups, but gains were significantly greater in the hypoxic (33 ± 12%) than the normoxic group (14 ± 10%, prepeated aerobic high intensity workout than an equivalent normoxic training. Performance gains are evident in the short term (4 weeks), a period similar to a preseason training block.

  15. Session-RPE for quantifying the load of different youth basketball training sessions

    Directory of Open Access Journals (Sweden)

    C Lupo

    2016-12-01

    Full Text Available The aim of the study was to evaluate youth basketball training, verifying the reliability of the session-RPE method in relation to session duration (< and ≥ 80 minutes and workout typology (reduced and high warm-up, conditioning, technical, tactical, game portions within a single session categories. Six male youth basketball players (age, 16.5±0.5 years; height, 195.5±6.75 cm; body mass, 93.9±10.9 kg; and body mass index, 23.6±2.8 kg.m-2 were monitored (HR, type and duration of workouts during 15 (66 individual training sessions (80±26 minutes. Edwards’ HR method was used as a reference measure of internal training load (ITL; the CR-10 RPE scale was administered 30 minutes after the end of each session. The results obtained showed that all comparisons between different session durations and workout portions revealed effects in term of Edwards’ ITLs except for warm-up portions. Moderate to strong relationships between Edwards’ and session- RPE methods emerged for all sessions (r = .85, P < .001, player’s sessions (r range = .79 - .95, P < .001, session durations (< 80 minutes: r = .67, P < .001; ≥ 80 minutes: r = .75, P < .001, and workout portions (r range = .78 - .89, P range = .002 - < .001. The findings indicated that coaches of youth basketball players can successfully use session-RPE to monitor the ITL, regardless of session durations and workout portions.

  16. US-guided biopsy of renal allografts using 18G biopsy gun: analysis of 200 cases

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Kyung; Lee, Jong Tae; Kim, Myeong Jin; Yoo, Hyung Sik; Kim, Ki Whang; Park, Ki Ill; Chung, Hyun Joo [Yonsei University, College of Medicine, Seoul (Korea, Republic of)

    1995-05-15

    We evaluated the effectiveness and safety of 18G biopsy gun with US guidance in the transplanted kidneys. We performed 200 US-guided percutaneous biopsies using 18G biopsy gun. Diagnostic efficacy and complication of the biopsy in these patients were analyzed. Biopsy specimens were adequate for histologic diagnoses in 193 patients(96.5%). The mean of the biopsy frequency was 3, the mean of total glomerular number was 21.64 and the mean glomerular number per one biopsy was 6.93. Major complications occurred in 3 (1.5%) of the 200 biopsies; hematuria developed in two patients, AV fistula in one. These complications were successfully controlled either by only transfusion or by coil embolization. There were no statistical differences in blood pressure, hemoglobin, BUN/Cr between pre-and post-renal biopsies. US-guided percutaneous biopsy of renal allograft with 18G biopsy gun is simple, safe, and accurate method in evaluating the renal allograft dysfunction.

  17. MRI-guided biopsy and fine needle aspiration biopsy (FNAB) in the diagnosis of musculoskeletal lesions

    Energy Technology Data Exchange (ETDEWEB)

    Kerimaa, Pekka, E-mail: pekka.kerimaa@ppshp.fi [Department of Radiology, Oulu University Hospital, P.O. Box 50, 90029 OYS (Finland); Marttila, Antti, E-mail: antti.marttila@ppshp.fi [Department of Radiology, Oulu University Hospital, P.O. Box 50, 90029 OYS (Finland); Hyvönen, Pekka, E-mail: pekka.hyvonen@ppshp.fi [Department of Surgery, Oulu University Hospital, P.O. Box 50, 90029 OYS (Finland); Ojala, Risto, E-mail: risto.ojala@ppshp.fi [Department of Radiology, Oulu University Hospital, P.O. Box 50, 90029 OYS (Finland); Lappi-Blanco, Elisa, E-mail: elisa.lappi-blanco@ppshp.fi [Department of Pathology, Oulu University Hospital, P.O. Box 50, 90029 OYS (Finland); Tervonen, Osmo, E-mail: osmo.tervonen@ppshp.fi [Department of Radiology, Oulu University Hospital, P.O. Box 50, 90029 OYS (Finland); Blanco Sequeiros, Roberto, E-mail: roberto.blanco@oulu.fi [Department of Radiology, Oulu University Hospital, P.O. Box 50, 90029 OYS (Finland)

    2013-12-01

    Objectives: The purpose of this study was to evaluate the diagnostic performance of magnetic resonance imaging (MRI) guided musculoskeletal biopsy and the value of fine needle aspiration biopsy (FNAB) when combined with histologic biopsy. Materials and methods: A total of 172 biopsies were performed under MRI guidance, 170 were histologic biopsies. In 112 cases, a fine needle aspiration biopsy was also performed. In two cases, a stand-alone FNAB was performed. The diagnostic performance was evaluated retrospectively by comparing the histopathologic and cytologic diagnosis with the current or final diagnosis after at least one year of clinical and imaging follow-up. A 0.23 T open MRI scanner with an interventional stereotactic guidance system was used. Results: The overall diagnostic accuracy of MRI guided biopsy was 0.95, sensitivity 0.91, specificity 0.98, positive predictive value (ppv) 0.97 and negative predictive value (npv) 0.93. The diagnostic accuracy of trephine biopsy alone was 0.93, sensitivity 0.89, specificity 0.98, ppv 0.97 and npv 0.91 and accuracy for FNAB alone was 0.85, sensitivity 0.80, specificity 0.90, ppv 0.89 and npv 0.82. Conclusions: MRI guidance is a feasible and accurate tool in percutaneous musculoskeletal biopsies. Fine needle biopsy is a useful low-cost supplement to histologic biopsy.

  18. 21 CFR 876.1075 - Gastroenterology-urology biopsy instrument.

    Science.gov (United States)

    2010-04-01

    ... generic type of device includes the biopsy punch, gastrointestinal mechanical biopsy instrument, suction... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gastroenterology-urology biopsy instrument. 876... Gastroenterology-urology biopsy instrument. (a) Identification. A gastroenterology-urology biopsy instrument is...

  19. The Effects of Repeated Exposure to Graphic Fear Appeals on Cigarette Packages: A Field Experiment

    NARCIS (Netherlands)

    Dijkstra, A.; Bos, C.

    2015-01-01

    Experimental studies on the effects of graphic fear appeals on cigarette packages typically expose smokers in a single session to a fear appeal, although in practice the exposure is always repeated. The present study applied an improved study design with repeated exposure to fear appeals on cigarett

  20. The Effects of Repeated Exposure to Graphic Fear Appeals on Cigarette Packages : A Field Experiment

    NARCIS (Netherlands)

    Dijkstra, Arie; Colin, Bos,

    2015-01-01

    Experimental studies on the effects of graphic fear appeals on cigarette packages typically expose smokers in a single session to a fear appeal, although in practice the exposure is always repeated. The present study applied an improved study design with repeated exposure to fear appeals on cigarett

  1. The Effects of Repeated Exposure to Graphic Fear Appeals on Cigarette Packages : A Field Experiment

    NARCIS (Netherlands)

    Dijkstra, Arie; Colin, Bos,

    2015-01-01

    Experimental studies on the effects of graphic fear appeals on cigarette packages typically expose smokers in a single session to a fear appeal, although in practice the exposure is always repeated. The present study applied an improved study design with repeated exposure to fear appeals on

  2. The Effects of Repeated Exposure to Graphic Fear Appeals on Cigarette Packages: A Field Experiment

    NARCIS (Netherlands)

    Dijkstra, A.; Bos, C.

    2015-01-01

    Experimental studies on the effects of graphic fear appeals on cigarette packages typically expose smokers in a single session to a fear appeal, although in practice the exposure is always repeated. The present study applied an improved study design with repeated exposure to fear appeals on

  3. Additional benefit of using a risk-based selection for prostate biopsy: an analysis of biopsy complications in the Rotterdam section of the European Randomized Study of Screening for Prostate Cancer.

    Science.gov (United States)

    Chiu, Peter K; Alberts, Arnout R; Venderbos, Lionne D F; Bangma, Chris H; Roobol, Monique J

    2017-09-01

    To investigate biopsy complications and hospital admissions that could be reduced by the use of European Randomized Study of Screening for Prostate Cancer (ERSPC) risk calculators. All biopsies performed in the Rotterdam section of the ERSPC between 1993 and 2015 were included. Biopsy complications and hospital admission data were prospectively recorded in questionnaires that were completed 2 weeks after biopsy. The ERSPC risk calculators 3 (RC3) and 4 (RC4) were applied to men attending the first and subsequent rounds of screening, respectively. Applying the predefined RC3/4 probability thresholds for prostate cancer (PCa) risk of ≥12.5% and high-grade PCa risk ≥3%, we assessed the number of complications, admissions and costs that could be reduced by avoiding biopsies in men below these thresholds. A total of 10 747 biopsies with complete questionnaires were included. For these biopsies a complication rate of 67.9% (7294/10 747), a post-biopsy fever rate of 3.9% (424/10747) and a hospital admission rate of 0.9% (92/10747) were recorded. The fever rate was found to be static over the years, but the hospital admission rate tripled from 0.6% (1993-1996) to 2.1% (2009-2015). Among 7704 biopsies which fit the criteria for RC3 or RC4, 35.8% of biopsies (2757/7704), 37.4% of complications (1972/5268), 39.4% of fever events (128/325) and 42.3% of admissions (30/71) could have been avoided by using one of the risk calculators. More complications could have been avoided if RC4 had been used and for more recent biopsies (2009-2015). Our findings show that 35.9% of the total cost of biopsies and complication treatment could have been avoided. A significant proportion of biopsy complications, hospital admissions and costs could be reduced if biopsy decisions were based on ERSPC risk calculators instead of PSA only. This effect was most prominent in more recent biopsies and in men with repeated biopsies or screening. © 2017 The Authors BJU International © 2017 BJU

  4. The Pentapeptide Repeat Proteins

    Energy Technology Data Exchange (ETDEWEB)

    Vetting,M.; Hegde, S.; Fajardo, J.; Fiser, A.; Roderick, S.; Takiff, H.; Blanchard, J.

    2006-01-01

    The Pentapeptide Repeat Protein (PRP) family has over 500 members in the prokaryotic and eukaryotic kingdoms. These proteins are composed of, or contain domains composed of, tandemly repeated amino acid sequences with a consensus sequence of [S, T,A, V][D, N][L, F]-[S, T,R][G]. The biochemical function of the vast majority of PRP family members is unknown. The three-dimensional structure of the first member of the PRP family was determined for the fluoroquinolone resistance protein (MfpA) from Mycobacterium tuberculosis. The structure revealed that the pentapeptide repeats encode the folding of a novel right-handed quadrilateral {beta}-helix. MfpA binds to DNA gyrase and inhibits its activity. The rod-shaped, dimeric protein exhibits remarkable size, shape and electrostatic similarity to DNA.

  5. Rectal forceps biopsy procedure in cystic fibrosis: technical aspects and patients perspective for clinical trials feasibility.

    Science.gov (United States)

    Servidoni, Maria F; Sousa, Marisa; Vinagre, Adriana M; Cardoso, Silvia R; Ribeiro, Maria A; Meirelles, Luciana R; de Carvalho, Rita B; Kunzelmann, Karl; Ribeiro, Antônio F; Ribeiro, José D; Amaral, Margarida D

    2013-05-20

    Measurements of CFTR function in rectal biopsies ex vivo have been used for diagnosis and prognosis of Cystic Fibrosis (CF) disease. Here, we aimed to evaluate this procedure regarding: i) viability of the rectal specimens obtained by biopsy forceps for ex vivo bioelectrical and biochemical laboratory analyses; and ii) overall assessment (comfort, invasiveness, pain, sedation requirement, etc.) of the rectal forceps biopsy procedure from the patients perspective to assess its feasibility as an outcome measure in clinical trials. We compared three bowel preparation solutions (NaCl 0.9%, glycerol 12%, mannitol), and two biopsy forceps (standard and jumbo) in 580 rectal specimens from 132 individuals (CF and non-CF). Assessment of the overall rectal biopsy procedure (obtained by biopsy forceps) by patients was carried out by telephone surveys to 75 individuals who underwent the sigmoidoscopy procedure. Integrity and friability of the tissue specimens correlate with their transepithelial resistance (r = -0.438 and -0.305, respectively) and are influenced by the bowel preparation solution and biopsy forceps used, being NaCl and jumbo forceps the most compatible methods with the electrophysiological analysis. The great majority of the individuals (76%) did not report major discomfort due to the short procedure time (max 15 min) and considered it relatively painless (79%). Importantly, most (88%) accept repeating it at least for one more time and 53% for more than 4 times. Obtaining rectal biopsies with a flexible endoscope and jumbo forceps after bowel preparation with NaCl solution is a safe procedure that can be adopted for both adults and children of any age, yielding viable specimens for CFTR bioelectrical/biochemical analyses. The procedure is well tolerated by patients, demonstrating its feasibility as an outcome measure in clinical trials.

  6. Plasma PGFM and progesterone concentrations, luteolysis moment and estrous cycle length in Nelore cows submitted to uterine biopsies

    Directory of Open Access Journals (Sweden)

    I. Martin

    2015-10-01

    Full Text Available ABSTRACTIn this study, endometrial samples were collected in 14 Nelore cows on days zero (ovulation, five, nine, thirteen and nineteen of the estrous cycle (biopsy group, and in 15 females these collections weren't performed (control group. Biopsies were done on the uterine horn endometrium contralateral to the ovary with corpus luteum. Blood samples were taken at -24, -16, -8, 0 +8, +16 and +24 hours in relation to progesterone drop (<1ng/mL, zero moment and evaluated for 13, 14-dihydro-15-keto prostaglandin F2-alpha (PGFM by radioimmunoassay (RIA. Plasma progesterone concentration was determined by RIA every 24 hours. Data were analyzed by ANOVA using the PROC GLM and MIXED of the SAS. The mean value for PGFM during the entire period evaluated was greater in the biopsy group. The mean concentration of PGFM at moment zero was not different between the groups; the mean concentration of PGFM was higher in the biopsy group before and after the drop in progesterone level. The maximum mean concentration observed was not different between the groups; however, the mean minimum concentration was different with high values in the biopsy group. Although the PGFM concentrations were higher in the biopsy group, the biopsy and control groups had similar length of estrous cycle showing that repeated endometrial biopsy on the side contralateral to the ovary with corpus luteum does not affect luteolysis and the length of the estrous cycle.

  7. Flexible session management in a distributed environment

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Zach; /Wisconsin U., Madison; Bradley, Dan; /Wisconsin U., Madison; Tannenbaum, Todd; /Wisconsin U., Madison; Sfiligoi, Igor; /Fermilab

    2010-01-01

    Many secure communication libraries used by distributed systems, such as SSL, TLS, and Kerberos, fail to make a clear distinction between the authentication, session, and communication layers. In this paper we introduce CEDAR, the secure communication library used by the Condor High Throughput Computing software, and present the advantages to a distributed computing system resulting from CEDAR's separation of these layers. Regardless of the authentication method used, CEDAR establishes a secure session key, which has the flexibility to be used for multiple capabilities. We demonstrate how a layered approach to security sessions can avoid round-trips and latency inherent in network authentication. The creation of a distinct session management layer allows for optimizations to improve scalability by way of delegating sessions to other components in the system. This session delegation creates a chain of trust that reduces the overhead of establishing secure connections and enables centralized enforcement of system-wide security policies. Additionally, secure channels based upon UDP datagrams are often overlooked by existing libraries; we show how CEDAR's structure accommodates this as well. As an example of the utility of this work, we show how the use of delegated security sessions and other techniques inherent in CEDAR's architecture enables US CMS to meet their scalability requirements in deploying Condor over large-scale, wide-area grid systems.

  8. VSS BASED SESSION SETUP MECHANISM IN IMS

    Institute of Scientific and Technical Information of China (English)

    Cao Yufei; Liao Jianxin; Qi Qi; Zhu Xiaomin

    2009-01-01

    This paper proposes a novel session setup mechanism in IMS (IP Multimedia Subsystem) by introducing the functional entity termed VSS (Visitor Subscriber Server) which is used to provide registration and location management.The new mechanism aims at improving session setup procedure by a betterment of location management in IMS.Through the use of two-tier subscriber information database constituted by the HSS (Home Subscriber Server) and the VSS,the new mechanism seperates the registration procedure and location management from the S-CSCF (Serving-Call'Session Control Function),and makes them be handled by the VSS.At the same time,the new mechanism updates the signaling procedure of registration and session setup.With VSS based location management.the cost of registeration and session setup procedure as well as the delay of session setup procedure become lower.he cost and delay functious of the new session setup mechanism as well aus the cost function of new registeration are deduced.Then,simulations and analysis verify that the performance of this new mechanism gets the benefit in cost and time.

  9. Repeating the Past

    Science.gov (United States)

    Moore, John W.

    1998-05-01

    As part of the celebration of the Journal 's 75th year, we are scanning each Journal issue from 25, 50, and 74 years ago. Many of the ideas and practices described are so similar to present-day "innovations" that George Santayana's adage (1) "Those who cannot remember the past are condemned to repeat it" comes to mind. But perhaps "condemned" is too strong - sometimes it may be valuable to repeat something that was done long ago. One example comes from the earliest days of the Division of Chemical Education and of the Journal.

  10. Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid ... Needle Aspiration Biopsy of the Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? ...

  11. Ultrasound guided pleural biopsy in undiagnosed exudative pleural effusion patients

    Directory of Open Access Journals (Sweden)

    Adel S. Ahmed

    2016-04-01

    In conclusion: Thoracic ultrasound (TUS guided pleural biopsy had a diagnostic yield which was slightly lower but comparable to both CT guided pleural biopsy and medical thoracoscopic pleural biopsy (MT.

  12. Session Types = Intersection Types + Union Types

    CERN Document Server

    Padovani, Luca

    2011-01-01

    We propose a semantically grounded theory of session types which relies on intersection and union types. We argue that intersection and union types are natural candidates for modeling branching points in session types and we show that the resulting theory overcomes some important defects of related behavioral theories. In particular, intersections and unions provide a native solution to the problem of computing joins and meets of session types. Also, the subtyping relation turns out to be a pre-congruence, while this is not always the case in related behavioral theories.

  13. Radial scars without atypia in percutaneous biopsy specimens: can they obviate surgical biopsy?

    Science.gov (United States)

    Mesa-Quesada, J; Romero-Martín, S; Cara-García, M; Martínez-López, A; Medina-Pérez, M; Raya-Povedano, J L

    2017-06-06

    To evaluate the need for surgical biopsy in patients diagnosed with radial scars without atypia by percutaneous biopsy. In this retrospective observational study, we selected patients with a histological diagnosis of radial scar in specimens obtained by percutaneous biopsy during an 8-year period. The statistical analysis was centered on patients with radial scar without atypia (we assessed the radiologic presentation, the results of the percutaneous biopsy, and their correlation with the results of surgical biopsy and follow-up) and we added the patients with atypia and cancer in the elaboration of the diagnostic indices. We identified 96 patients with radial scar on percutaneous biopsy; 54 had no atypia, 18 had atypia, and 24 had cancer. Among patients with radial scar without atypia, there were no statistically significant differences between patients who underwent imaging follow-up and those who underwent surgical biopsy (p>0.05). The rate of underdiagnosis for percutaneous biopsy in patients without atypia was 1.9%. The rates of diagnosis obtained with percutaneous biopsy in relation to follow-up and surgical biopsy in the 96 cases were sensitivity 92.3%, specificity 100%, positive predictive value 100%, negative predictive value 97.2%, and accuracy 97.9%. The area under the ROC curve was 0.96 (p<0.001), and the kappa concordance index was 0.95 (p<0.001) CONCLUSIONS: We consider that it is not necessary to perform surgical biopsies in patients with radial scars without atypia on percutaneous biopsies because the rate of underestimation is very low and the concordance between the diagnosis reached by percutaneous biopsy and the definitive diagnosis is very high. Copyright © 2017 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. Status quo and development trend of breast biopsy technology

    OpenAIRE

    Zhang, Yan-Jun; Wei, Lichun; Li, Jie; Yi-qiong ZHENG; Li, Xi-Ru

    2013-01-01

    Triple assessment is a standard method for assessment of breast diseases, which includes clinical evaluation, radiographic assessment and pathological assessment. Biopsy for breast disease is the gold standard for pathological assessment, including incisional biopsy, excisional biopsy, core needle biopsy, vacuum-assisted biopsy and bite biopsy. With the continuous advancement of diagnostic and treatment technology for breast cancer, collection of diseased tissue has also undergone a gradual t...

  15. All-optical repeater.

    Science.gov (United States)

    Silberberg, Y

    1986-06-01

    An all-optical device containing saturable gain, saturable loss, and unsaturable loss is shown to transform weak, distorted optical pulses into uniform standard-shape pulses. The proposed device performs thresholding, amplification, and pulse shaping as required from an optical repeater. It is shown that such a device could be realized by existing semiconductor technology.

  16. Bidirectional Manchester repeater

    Science.gov (United States)

    Ferguson, J.

    1980-01-01

    Bidirectional Manchester repeater is inserted at periodic intervals along single bidirectional twisted pair transmission line to detect, amplify, and transmit bidirectional Manchester 11 code signals. Requiring only 18 TTL 7400 series IC's, some line receivers and drivers, and handful of passive components, circuit is simple and relatively inexpensive to build.

  17. The utility of ultrasound-guided thoracentesis and pleural biopsy in undiagnosed pleural exudates.

    Science.gov (United States)

    Koegelenberg, Coenraad Frederik N; Irusen, Elvis Malcom; von Groote-Bidlingmaier, Florian; Bruwer, Johannes Willem; Batubara, Enas Mansour A; Diacon, Andreas Henri

    2015-10-01

    We assessed the utility of ultrasound to guide the selection of closed pleural biopsy technique and site and to assess the respective contributions of repeat thoracentesis and closed pleural biopsy in 100 consecutive patients with undiagnosed pleural exudates. Thoracentesis was more likely to be diagnostic in TB than malignancy (77.8% vs 31.0%, p<0.001). The addition of ultrasound-guided biopsy increased the combined yield for all diagnoses from 48.0% to 90.0% (p<0.001), for malignancy from 31.0% to 89.7% (p<0.001) and for TB from 77.8% to 88.9% (p=0.688). Our findings suggest that this minimally invasive approach has a high diagnostic yield. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  18. Gene Expression analysis of the endometrium after endometrial biopsy in fertile women

    DEFF Research Database (Denmark)

    Olesen, Mia Steengaard; Starnawska, Anna; Agerholm, Inge;

    Background Recent data indicate, that therapeutic endometrial injury, may enhance implantation in assisted reproductive therapy (ART). Aim The aim of this pilot study was to investigate the gene expression and epigenetic modifications after an endometrial biopsy in fertile women. Material...... (baseline) and repeated in the next cycle at day LH+7 (after biopsy). Endometrial biopsies were homogenized and RNA/DNA extracted. Gene expression was analyzed using RNAseq. DNA methylation was analyzed using Illumina 450K methylation array. Results Preliminary results show differentially expressed genes...... and Methods The study is part of a large prospective clinical study. Six fertile women, with no prior use of intrauterine device or anticonception pills, underwent a therapeutic endometrial injury with a Pipelle de CornierR in two consecutive cycles. The endometrial samples were taken at cycle day LH+7...

  19. Prostate biopsy tracking with deformation estimation

    CERN Document Server

    Baumann, Michael; Daanen, Vincent; Troccaz, Jocelyne

    2011-01-01

    Transrectal biopsies under 2D ultrasound (US) control are the current clinical standard for prostate cancer diagnosis. The isoechogenic nature of prostate carcinoma makes it necessary to sample the gland systematically, resulting in a low sensitivity. Also, it is difficult for the clinician to follow the sampling protocol accurately under 2D US control and the exact anatomical location of the biopsy cores is unknown after the intervention. Tracking systems for prostate biopsies make it possible to generate biopsy distribution maps for intra- and post-interventional quality control and 3D visualisation of histological results for diagnosis and treatment planning. They can also guide the clinician toward non-ultrasound targets. In this paper, a volume-swept 3D US based tracking system for fast and accurate estimation of prostate tissue motion is proposed. The entirely image-based system solves the patient motion problem with an a priori model of rectal probe kinematics. Prostate deformations are estimated with ...

  20. GoM Coastal Biopsy Surveys - NRDA

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Small vessel surveys were conducted within estuarine and nearshore coastal waters of Barataria Bay, LA and Mississippi Sound, MS to collect tissue biopsy samples...

  1. Salivary Gland Biopsy for Sjogren's Syndrome

    NARCIS (Netherlands)

    Delli, Konstantina; Vissink, Arjan; Spijkervet, Fred K. L.

    2014-01-01

    Salivary gland biopsy is a technique broadly applied for the diagnosis of Sjogren's syndrome (SS), lymphoma accompanying SS, sarcoidosis, amyloidosis, and other connective tissue disorders. SS has characteristic microscopic findings involving lymphocytic infiltration surrounding the excretory ducts

  2. Salivary Gland Biopsy for Sjogren's Syndrome

    NARCIS (Netherlands)

    Delli, Konstantina; Vissink, Arjan; Spijkervet, Fred K. L.

    2014-01-01

    Salivary gland biopsy is a technique broadly applied for the diagnosis of Sjogren's syndrome (SS), lymphoma accompanying SS, sarcoidosis, amyloidosis, and other connective tissue disorders. SS has characteristic microscopic findings involving lymphocytic infiltration surrounding the excretory ducts

  3. Status quo and development trend of breast biopsy technology.

    Science.gov (United States)

    Zhang, Yan-Jun; Wei, Lichun; Li, Jie; Zheng, Yi-Qiong; Li, Xi-Ru

    2013-02-01

    Triple assessment is a standard method for assessment of breast diseases, which includes clinical evaluation, radiographic assessment and pathological assessment. Biopsy for breast disease is the gold standard for pathological assessment, including incisional biopsy, excisional biopsy, core needle biopsy, vacuum-assisted biopsy and bite biopsy. With the continuous advancement of diagnostic and treatment technology for breast cancer, collection of diseased tissue has also undergone a gradual transition from traditional open surgery to biopsy. This review summarizes the current situation and development of breast biopsy technology to provide an insight into the latest details such as the safety and reliability as the basis for selection of the most appropriate techniques for specific settings.

  4. Navigation-guided endoscopic biopsy for intraparenchymal brain tumor.

    Science.gov (United States)

    Tsuda, Kyoji; Ishikawa, Eiichi; Zaboronok, Alexander; Nakai, Kei; Yamamoto, Tetsuya; Sakamoto, Noriaki; Uemae, Yoji; Tsurubuchi, Takao; Akutsu, Hiroyoshi; Ihara, Satoshi; Ayuzawa, Satoshi; Takano, Shingo; Matsumura, Akira

    2011-01-01

    To evaluate the efficacy of intraparenchymal brain tumor biopsy using endoscopy and a navigation system (navigation-guided endoscopic biopsy) as a diagnostic tool, a case series of intraparenchymal tumor biopsies was reviewed. Navigation-guided endoscopic biopsy was applied in 9 cases, stereotactic needle biopsy in 16 cases, and open biopsy with or without navigation system in 34 cases. In all biopsy cases, 84.7% of biopsy points were sampled accurately, and 93.2% of diagnoses by biopsy were correct. Comparison of each type of biopsy showed that the resected volumes in navigation-guided endoscopic biopsy and open biopsy tended to be larger than those in stereotactic biopsy, and the mean operation time for the open biopsy procedure was the longest. To define the most applicable device or examination method to increase sampling accuracy, various factors were analyzed in 59 procedures. Navigation-guided endoscopic biopsy was the most accurate of the three types of biopsy, although the statistical difference was not significant. Older patients, histological diagnosis of high-grade glioma or malignant lymphoma, positive photodynamic diagnosis, and positive intraoperative pathology were significant factors in improving the sampling accuracy. Navigation-guided endoscopic biopsy could provide a larger sample volume within a relatively short operation time. The biopsy can be easily combined with both photodynamic diagnosis and intraoperative pathology, significantly improving the histological diagnostic yield.

  5. Session on computation in biological pathways

    Energy Technology Data Exchange (ETDEWEB)

    Karp, P.D. [SRI International, Menlo Park, CA (United States); Riley, M. [Marine Biological Lab., Woods Hole, MA (United States)

    1996-12-31

    The papers in this session focus on the development of pathway databases and computational tools for pathway analysis. The discussion involves existing databases of sequenced genomes, as well as techniques for studying regulatory pathways.

  6. Ultrasound-guided percutaneous renal biopsy with an automated biopsy gun in diffuse renal disease

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Yang; Moon, Jeoung Mi; Park, Ji Hyun; Kwon, Jae Soo; Song, Ik Hoon; Kim, Sung Rok [Masan Koryo General Hospital, Masan (Korea, Republic of)

    1994-12-15

    We evaluated the effectiveness and clinical usefulness of percutaneous renal biopsy by using automated biopsy gun under the real-time ultrasonographic guidance that was performed in 17 patients with diffuse renal disease. We retrospectively analysed the histopathological diagnosis and the patients' status after percutaneous renal biopsy.Adequate amount of tissue for the histologic diagnosis could be obtained in al patients. Histopathologic diagnosis included the minimal change nephrotic syndrome in 6 patients, the membrano proliferative glomerulonephritis in 4,the membranous glomerulonephritis in 2, the glomerulosclerosis in 2, Ig A nephropathy in 2, and the normal finding in 1. Significant complication occurred in only one patient who developed a transient loss of sensation at and around the biopsy site. In conclusion, automated biopsy gun was a very useful device in performing percutaneous biopsy for diffuse renal disease with a high success rate and a low complication rate

  7. 不用Cookies实现的session

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    第一.不能有多个sessionID.那样URL会变得很长。关掉浏览器,或丢了sessionID参数session也就没用了.除非每次都在URL后面冒着sessionID参数。暂时不考虑这个问题.把存活期屏蔽。

  8. ICTNET at Session Track TREC2014

    Science.gov (United States)

    2014-11-01

    expansion score of the document. SVD The score of the session visual document model. UAT The score of user attention time model. BM25QC The BM25...QE, SVD , UAT, BM25QC, CosSimQT, Clicked BM25QC, CosSimQT, SVD , QE CosSimQT, SVD , QE, UAT RL3 The same as above except that it use all the sessions

  9. Testicular biopsy: clinical practice and interpretation

    Institute of Scientific and Technical Information of China (English)

    Gert R Dohle; Saad Elzanaty; Niels J van Casteren

    2012-01-01

    Testicular biopsy was considered the cornerstone of male infertility diagnosis for many years in men with unexplained infertility and azoospermia.Recent guidelines for male infertility have limited the indications for a diagnostic testicular biopsy to the confirmation ofobstructive azoospermia in men with normal size testes and normal reproductive hormones.Nowadays,testicular biopsies are mainly performed for sperm harvesting in men with non-obstructive azoospermia,to be used for intracytoplasmic sperm injection.Testicular biopsy is also performed in men with risk factors for testicular malignancy.In a subgroup of infertile men,there is an increased risk for carcinoma in situ of the testis,especially in men with a history of cryptorchidism and testicular malignancy and in men with testicular atrophy.Ultrasonographic abnormalities,such as testicular microlithiasis,inhomogeneous parenchyma and lesions of the testes,further increase the risk of carcinoma in situ (CIS) in these men.For an accurate histological classification,proper tissue handling,fixation,preparation of the specimen and evaluation are needed.A standardized approach to testicular biopsy is recommended.In addition,approaches to the detection of CIS of the testis testicular immunohistochemistry are mandatory.In this mini-review,we describe the current indications for testicular biopsies in the diagnosis and management of male infertility.

  10. Gene expression in human skeletal muscle: alternative normalization method and effect of repeated biopsies

    DEFF Research Database (Denmark)

    Lundby, Carsten; Nordsborg, Nikolai; Kusuhara, K.

    2005-01-01

    The reverse transcriptase-polymerase chain reaction (RT-PCR) method has lately become widely used to determine transcription and mRNA content in rodent and human muscle samples. However, the common use of endogenous controls for correcting for variance in cDNA between samples is not optimal. Spec...

  11. Duct Leakage Repeatability Testing

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sherman, Max [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-01-01

    Duct leakage often needs to be measured to demonstrate compliance with requirements or to determine energy or Indoor Air Quality (IAQ) impacts. Testing is often done using standards such as ASTM E1554 (ASTM 2013) or California Title 24 (California Energy Commission 2013 & 2013b), but there are several choices of methods available within the accepted standards. Determining which method to use or not use requires an evaluation of those methods in the context of the particular needs. Three factors that are important considerations are the cost of the measurement, the accuracy of the measurement and the repeatability of the measurement. The purpose of this report is to evaluate the repeatability of the three most significant measurement techniques using data from the literature and recently obtained field data. We will also briefly discuss the first two factors. The main question to be answered by this study is to determine if differences in the repeatability of these tests methods is sufficient to indicate that any of these methods is so poor that it should be excluded from consideration as an allowed procedure in codes and standards.

  12. Working session 5: Operational aspects and risk analysis

    Energy Technology Data Exchange (ETDEWEB)

    Cizelj, L. [Jozef Stefan Institute, Ljubljana (Slovenia); Donoghue, J. [Nuclear Regulatory Commission, Washington, DC (United States)

    1997-02-01

    A general observation is that both operational aspects and risk analysis cannot be adequately discussed without information presented in other sessions. Some overlap of conclusions and recommendations is therefore to be expected. Further, it was assumed that recommendations concerning improvements in some related topics were generated by other sessions and are not repeated here. These include: (1) Knowledge on degradation mechanisms (initiation, progression, and failure). (2) Modeling of degradation (initiation, progression, and failure). (3) Capabilities of NDE methods. (4) Preventive maintenance and repair. One should note here, however, that all of these directly affect both operational and risk aspects of affected plants. A list of conclusions and recommendations is based on available presentations and discussions addressing risk and operational experience. The authors aimed at reaching as broad a consensus as possible. It should be noted here that there is no strict delineation between operational and safety aspects of degradation of steam generator tubes. This is caused by different risk perceptions in different countries/societies. The conclusions and recommendations were divided into four broad groups: human reliability; leakage monitoring; risk impact; and consequence assessment.

  13. Comparison of CT and PET/CT for biopsy guidance in oncological patients.

    Science.gov (United States)

    Cerci, Juliano J; Tabacchi, Elena; Bogoni, Mateos; Delbeke, Dominique; Pereira, Carlos Cunha; Cerci, Rodrigo J; Krauzer, Cassiano; Sakamoto, Danielle Giacometti; Fanti, Stefano; Vitola, João Vicente

    2017-08-01

    To compare FDG PET/CT and CT for the guidance of percutaneous biopsies with histological confirmation of lesions. We prospectively evaluated 323 patients of whom 181 underwent FDG PET/CT-guided biopsy (total 188 biopsies) and 142 underwent CT-guided biopsy (total 146 biopsies). Biopsies were performed using the same PET/CT scanner with a fluoroscopic imaging system. Technical feasibility, clinical success and complication rates in the two groups were evaluated. Of the 188 biopsies with PET/CT guidance, 182 (96.8%) were successful with conclusive tissue samples obtained and of the 146 biopsies with CT guidance, 137 (93.8%) were successful. Therefore, 6 of 188 biopsies (3.1%) with PET/CT guidance and 9 of 146 (6.1%) with CT guidance were inconclusive (p = 0.19). Due to inconclusive histological results, 4 of the 188 lesions (2.1%) were rebiopsied with PET/CT guidance and 3 of 146 lesions (2.0%) were rebiopsied with CT guidance. Histology demonstrated that 142 of 188 lesions (75.5%) were malignant, and 40 (21.2%) were benign in the PET/CT-guided group, while 89 of 146 lesions (60.9%) were malignant and 48 (32.8%) were benign in the CT-guided group (p = 0.004 and 0.01, respectively). Patients with a histological diagnosis of benign lesion had no recurrence of disease with a minimum of 6 months follow-up. Of the 188 PET/CT-guided biopsies, 6 (3.1%) were repeat biopsies due to a previous nondiagnostic CT-guided biopsy performed in a different diagnostic centre. The interval between the two biopsies was less than a month in all cases. Histology revealed five malignant lesions and one benign lesion among these. The complication rate in the PET/CT-guided biopsy group was 12.7% (24 of 188), while in the CT-guided group, was 9.5% (14 of 146, p = 0.26). Therefore, there was no significant difference in complication rates between PET/CT and CT guidance. PET/CT-guided biopsy is already known to be a feasible and accurate method in the diagnostic work-up of suspected

  14. Small renal mass biopsy--how, what and when: report from an international consensus panel.

    Science.gov (United States)

    Tsivian, Matvey; Rampersaud, Edward N; del Pilar Laguna Pes, Maria; Joniau, Steven; Leveillee, Raymond J; Shingleton, William B; Aron, Monish; Kim, Charles Y; DeMarzo, Angelo M; Desai, Mihir M; Meler, James D; Donovan, James F; Klingler, Hans Christoph; Sopko, David R; Madden, John F; Marberger, Michael; Ferrandino, Michael N; Polascik, Thomas J

    2014-06-01

    To discuss the use of renal mass biopsy (RMB) for small renal masses (SRMs), formulate technical aspects, outline potential pitfalls and provide recommendations for the practicing clinician. The meeting was conducted as an informal consensus process and no scoring system was used to measure the levels of agreement on the different topics. A moderated general discussion was used as the basis for consensus and arising issues were resolved at this point. A consensus was established and lack of agreement to topics or specific items was noted at this point. Recommended biopsy technique: at least two cores, sampling different tumour regions with ultrasonography being the preferred method of image guidance. Pathological interpretation: 'non-diagnostic samples' should refer to insufficient material, inconclusive and normal renal parenchyma. For non-diagnostic samples, a repeat biopsy is recommended. Fine-needle aspiration may provide additional information but cannot substitute for core biopsy. Indications for RMB: biopsy is recommended in most cases except in patients with imaging or clinical characteristics indicative of pathology (syndromes, imaging characteristics) and cases whereby conservative management is not contemplated. RMB is recommended for active surveillance but not for watchful-waiting candidates. We report the results of an international consensus meeting on the use of RMB for SRMs, defining the technique, pathological interpretation and indications.

  15. Renography and biopsy-verified acute rejection in renal allotransplanted patients receiving cyclosporin A

    Energy Technology Data Exchange (ETDEWEB)

    Thomsen, H.S.; Nielsen, S.L.; Larsen, S.; Lokkegaard, H.

    1987-01-01

    Acute impairment of renal function caused by cyclosporin A can be hard to differentiate from acute rejection. Therefore, kidney function after cadaveric allograft transplantation was repeatedly determined by renography in 42 patients receiving either high dose cyclosporin A (32 patients) or azathioprine and prednisone (10 patients) until a graft biopsy showed either acute rejection or no rejection within the first 5 postoperative weeks. The graft function as judged from the renograms was significantly poorer when cyclosporin A was used than when azathioprine and prednisone were the immunosuppressants. In the azathioprine and prednisone group a biopsy showing acute rejection was always preceded by a deterioration in the renogram. In cyclosporin A treated patients a graft biopsy following an early deterioration in the renogram showed acute rejection in only 56% of the biopsies. It was not possible to identify a time course or a function level of the renogram that could predict rejection in these patients. It is concluded that graft biopsies should be used liberally to diagnose rejection during cyclosporin A treatment if surgical complications after transplantations have been ruled out. Radionuclide studies may offer an invaluable aid in determining a nonnephrotoxic initial dose of the drug.

  16. 76 FR 42112 - Specialty Crop Committee Stakeholder Listening Sessions

    Science.gov (United States)

    2011-07-18

    ...; ] DEPARTMENT OF AGRICULTURE Office of the Secretary Specialty Crop Committee Stakeholder Listening Sessions AGENCY: Research, Education, and Economics, USDA. ACTION: Notice of stakeholder listening sessions... Department of Agriculture announces two stakeholder listening sessions of the Specialty Crop Committee,...

  17. CT fluoroscopy guided transpleural cutting needle biopsy of small ({<=}2.5 cm) subpleural pulmonary nodules

    Energy Technology Data Exchange (ETDEWEB)

    Prosch, Helmut; Oschatz, Elisabeth; Eisenhuber, Edith; Wohlschlager, Helmut [Otto Wagner Hospital, Department of Radiology, Sanatoriumsstrasse 2, 1140 Vienna (Austria); Mostbeck, Gerhard H., E-mail: gerhard.mostbeck@wienkav.at [Otto Wagner Hospital, Department of Radiology, Sanatoriumsstrasse 2, 1140 Vienna (Austria)

    2011-01-15

    Purpose: Small subpleural pulmonary lesions are difficult to biopsy. While the direct, short needle path has been reported to have a lower rate of pneumothorax, the indirect path provides a higher diagnostic yield. Therefore, we tried to optimize the needle pathway and minimize the iatrogenic pneumothorax risk by evaluating a CT fluoroscopy guided direct approach to biopsy subpleural lesions. Material and methods: Between 01/2005 and 01/2007, CT fluoroscopy guided core biopsies were performed in 24 patients. Using our technique, the tip of the guide needle remains outside the visceral pleura (17 G coaxial guide needle, 18 G Biopsy-gun, 15 or 22 mm needle path). The position of the lesion relative to the needle tip can be optimized using CT fluoroscopy by adjusting the breathing position of the patient. The Biopty gun is fired with the needle tip still outside the pleural space. Cytological smears are analyzed by a cytopathologist on-site, and biopsies are repeated as indicated with the coaxial needle still outside the pleura. Results: Median nodule size was 1.6 cm (0.7-2.3 cm). A definitive diagnosis was obtained in 22 patients by histology and/or cytology. In one patient, only necrotic material could be obtained. In another patient, the intervention had to be aborted as the dyspnoic patient could not follow breathing instructions. An asymptomatic pneumothorax was present in seven patients; chest tube placement was not required. Conclusion: The presented biopsy approach has a high diagnostic yield and is especially advantageous for biopsies of small subpleural lesions in the lower lobes.

  18. Does Leaving the Biopsy Needle in Povidone-Iodine Solution Reduce Infective Complications after Biopsy?

    Directory of Open Access Journals (Sweden)

    Erdal Benli

    2016-01-01

    Full Text Available Aim. The aim of this study is to evaluate whether leaving the biopsy needle used during prostate needle biopsy in 10% povidone-iodine (betadine solution affects the infectious complications forming after biopsy. Material and Method. This study retrospectively evaluated the data of 176 patients with prostate biopsy performed between December 2012 and April 2014. Patients in Group 1 (n=89 were given ofloxacin as a prophylactic antibiotic before biopsy. Patients in Group 2 (n=87 had the biopsy needle left in povidone-iodine solution for 1 minute before each use, in addition to antibiotic prophylaxis. The two groups were compared in terms of infective complications developing after biopsy. Results were analyzed using the Mann–Whitney U test and Fisher’s exact test. Results. The distribution of infective complications after biopsy according to group was as follows. Group 1, not using betadine, had 15.7% fever, 13.5% hospital stay, 12.4% urinary retention, 10.1% prostatitis, and 5.6% sepsis. The distribution of the same complications in Group 2 using betadine was identified as 5.7% fever, 4.6% hospital stay, 3.4% urinary retention, 2.3% prostatitis, and 0% sepsis. The use of betadine was found to significantly reduce the infectious complications after biopsy compared to the control group (p<0.05. Conclusion. At the end of this study leaving the prostate needle in povidone-iodine solution before each use during prostate biopsy was found to reduce the infective complications and hospital stay after biopsy.

  19. Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors.

    Science.gov (United States)

    Chae, In Hye; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young

    2017-07-01

    To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma. A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed. Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P fine needle aspiration, gender, age, size, presence of vascularity, and suspicious US features were not associated with post-biopsy hematoma according to experience level. Post-biopsy hematoma occurred significantly more with ultrasound guided-core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P biopsy hematoma occurred significantly more in ultrasound guided-core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.

  20. Obesity does not correlate with adverse pathologic findings on transperineal template-guided mapping biopsy of the prostate.

    Science.gov (United States)

    Bittner, Nathan; Merrick, Gregory S; Stewart, Renee; Andreini, Hugo; Taubenslag, Walter; Curtis, Rodney; Butler, Wayne M; Wallner, Kent E

    2011-01-01

    Obesity has correlated with adverse pathologic features on prostate biopsy and may predispose to a higher rate of prostate cancer-related death after radical prostatectomy. In this study, we examine the potential relationship between body mass index (BMI) and histopathologic findings on transperineal template-guided mapping biopsy of the prostate (TTMB). From January 2005 to January 2008, 244 consecutive patients underwent TTMB using an anatomic-based technique. The criteria for TTMB included previously negative transrectal ultrasound (TRUS) biopsy with persistently elevated PSA and/or diagnosis of ASAP, or HG-PIN. The study population was divided into 4 different BMI cohorts (BMI prostate volume, were not significantly different between the various BMI cohorts. On average, the study population had undergone 1.7 TRUS biopsies before TTMB. Of the 244 study patients, 112 (45.9%), were diagnosed with prostate adenocarcinoma on TTMB. There was no difference in the rate of cancer detection between the different BMI cohorts. Among patients diagnosed with prostate cancer, BMI did not correlate with Gleason score or percent of positive biopsy cores. When the geography of biopsy-positive cores was analyzed, there were no statistically significant differences in cancer location among the different BMI groups. In this study, obesity did not predispose toward higher Gleason score, larger cancer volume, or geographic cancer distribution on repeat biopsy with TTMB. Copyright © 2011 Elsevier Inc. All rights reserved.

  1. [Frameless stereotactic biopsy: diagnostic yield and complications].

    Science.gov (United States)

    Castle, Maria; Nájera, Edinson; Samprón, Nicolas; Bollar, Alicia; Urreta, Iratxe; Urculo, Enrique

    2014-01-01

    The aim of this study was to evaluate the variables that could modify the diagnostic yield of frameless stereotactic biopsy, as well as its complications. This was a retrospective study of frameless stereotactic biopsies carried out between July 2008 and December 2011 at Donostia University Hospital. The variables studied were size, distance to the cortex, contrast uptake and location. A total of 70 patients were included (75 biopsies); 39 males and 31 females with an age range between 39 and 83 years. The total diagnostic yield in our series was 97.1%. For lesions >19mm, the technique offered a sensitivity of 95.2% (95% CI: 86.9-98.4) and specificity of 57.1% (95% CI: 25.0-84.2). The yield was lower for lesions within 17mm of the cortex: sensitivity of 74.6% (95% CI: 62.1-84.7) and specificity of 71.4% (95% CI: 29.0-96.3). Seven (10%) patients developed complications after the first biopsy and none after the second. The diagnostic yield was lower for lesions less than 2cm in size and located superficially. In this series we did not observe an increased rate of complications after a second biopsy. Copyright © 2013 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.

  2. Intersections and Unions of Session Types

    Directory of Open Access Journals (Sweden)

    Coşku Acay

    2017-02-01

    Full Text Available Prior work has extended the deep, logical connection between the linear sequent calculus and session-typed message-passing concurrent computation with equi-recursive types and a natural notion of subtyping. In this paper, we extend this further by intersection and union types in order to express multiple behavioral properties of processes in a single type. We prove session fidelity and absence of deadlock and illustrate the expressive power of our system with some simple examples. We observe that we can represent internal and external choice by intersection and union, respectively, which was previously suggested by Padovani for a different language of session types motivated by operational rather than logical concerns.

  3. Instruments for documentation of music therapy sessions

    DEFF Research Database (Denmark)

    Ridder, Hanne Mette Ochsner

    It is an important part of the clinical music therapy work to document the daily sessions. For the clinician it is necessary to have a brief overview of each session in order to assess the methods and the process, and not least to be able to give clear reports of these issues to other health care...... professionals at staff meetings, conferences, etc. For music therapists with many clients there is not time enough during a working day to provide comprehensive process descriptions in the music therapy log. Therefore instruments that help the clinician in reducing and structuring this information are needed....... Danish and Norwegian music therapist have collaborated on developing a one page sheet with a structured form where they after each music therapy session document their use of methods and techniques in individual music therapy with persons with dementia. With this instrument therapists have easy access...

  4. Instruments for documentation of music therapy sessions

    DEFF Research Database (Denmark)

    Ridder, Hanne Mette Ochsner

    It is an important part of the clinical music therapy work to document the daily sessions. For the clinician it is necessary to have a brief overview of each session in order to assess the methods and the process, and not least to be able to give clear reports of these issues to other health care...... professionals at staff meetings, conferences, etc. For music therapists with many clients there is not time enough during a working day to provide comprehensive process descriptions in the music therapy log. Therefore instruments that help the clinician in reducing and structuring this information are needed....... Danish and Norwegian music therapist have collaborated on developing a one page sheet with a structured form where they after each music therapy session document their use of methods and techniques in individual music therapy with persons with dementia. With this instrument therapists have easy access...

  5. Performing bone marrow biopsies with or without sedation: a comparison.

    Science.gov (United States)

    Giannoutsos, I; Grech, H; Maboreke, T; Morgenstern, G

    2004-06-01

    Although intravenous sedation (ISED) in addition to a local anaesthetic (LA) is commonly used in the performance of a bone marrow aspirate and trephine (BMAT), it is not clear under what circumstances and in which way sedation may be most beneficial. In this study, information was gathered using a questionnaire, from 112 patients shortly after undergoing BMAT; the duration of the procedures and the length of the biopsy cores were measured and any complications noted. Most patients (68%) chose to receive LA only, and almost all (74/76) were happy with their decision. Patients who received sedation gave lower pain scores than patients receiving LA only (1 vs. 3) and were found to have lower levels of apprehension at the thought of having a repeat procedure. Patients having a repeat BMAT showed a slightly increased preference for having sedation compared with patients who were undergoing it for the first time. There is some concern that guidelines regarding the use of ISED for procedures other than BMAT are not always adhered to, and current practice may be best revealed by a large-scale audit of sedation practice for the performance of BMAT. Patients should be given the choice of having ISED if the appropriate resources are available, but in most cases the additional small risk of receiving sedation can be avoided.

  6. Oral biopsy: Oral pathologist′s perspective

    Directory of Open Access Journals (Sweden)

    K L Kumaraswamy

    2012-01-01

    Full Text Available Many oral lesions may need to be diagnosed by removing a sample of tissue from the oral cavity. Biopsy is widely used in the medical field, but the practice is not quite widespread in dental practice. As oral pathologists, we have found many artifacts in the tissue specimen because of poor biopsy technique or handling, which has led to diagnostic pitfalls and misery to both the patient and the clinician. This article aims at alerting the clinicians about the clinical faults arising preoperatively, intraoperatively and postoperatively while dealing with oral biopsy that may affect the histological assessment of the tissue and, therefore, the diagnosis. It also reviews the different techniques, precautions and special considerations necessary for specific lesions.

  7. Muscle biopsy findings in inflammatory myopathies.

    Science.gov (United States)

    Dalakas, Marinos C

    2002-11-01

    The inflammatory myopathies encompass a heterogeneous group of acquired muscle diseases characterized clinically, by muscle weakness, and histologically, by inflammatory infiltrates within the skeletal muscles. The group of these myopathies comprise three major and discrete subsets: polymyositis (PM), dermatomyositis (DM), and inclusion body myositis (IBM). Each subset retains its characteristic clinical, immunopathologic, and morphologic features regardless of whether it occurs separately or in connection with other systemic diseases. Although the diagnosis of these disorders is based on the combination of clinical examination, electromyographic data, serum muscle enzyme levels, various autoantibodies, and the muscle biopsy findings, the muscle biopsy offers the most definitive diagnostic information in the majority of the cases. This article summarizes the main histologic features that characterize PM, DM, or IBM and emphasizes the main pitfalls associated with interpretation of the biopsies.

  8. Renal Biopsy in Type 2 Diabetic Patients

    Directory of Open Access Journals (Sweden)

    Eugenia Espinel

    2015-05-01

    Full Text Available The majority of diabetic patients with renal involvement are not biopsied. Studies evaluating histological findings in renal biopsies performed in diabetic patients have shown that approximately one third of the cases will show pure diabetic nephropathy, one third a non-diabetic condition and another third will show diabetic nephropathy with a superimposed disease. Early diagnosis of treatable non-diabetic diseases in diabetic patients is important to ameliorate renal prognosis. The publication of the International Consensus Document for the classification of type 1 and type 2 diabetes has provided common criteria for the classification of diabetic nephropathy and its utility to stratify risk for renal failure has already been demonstrated in different retrospective studies. The availability of new drugs with the potential to modify the natural history of diabetic nephropathy has raised the question whether renal biopsies may allow a better design of clinical trials aimed to delay the progression of chronic kidney disease in diabetic patients.

  9. Prostate cancer detection with MR-ultrasound fusion biopsy: the role of systematic and targeted biopsies

    Science.gov (United States)

    Filson, Christopher P.; Natarajan, Shyam; Margolis, Daniel J.A.; Huang, Jiaoti; Lieu, Patricia; Dorey, Frederick J.; Reiter, Robert E.; Marks, Leonard S.

    2015-01-01

    BACKGROUND To evaluate performance of magnetic resonance (MR)-ultrasound guided fusion biopsy in diagnosing clinically significant prostate cancer (csCaP). METHODS 1042 men underwent multi-parametric MRI (mpMRI) and fusion biopsy consecutively in a prospective trial (2009 – 2014). An expert reader graded mpMRI regions of interest (ROI) 1–5 using published protocols. The fusion biopsy device was used to obtain targeted cores from ROIs (when present) followed by a fusion-image guided 12-core systematic biopsy in all men, even if no suspicious ROI. Primary endpoint was detection of clinically significant CaP (i.e., Gleason score ≥ 7). RESULTS Among 825 men with ≥ 1 suspicious ROI of grade 3 or higher, 289 (35%) had csCaP. Powerful predictors of csCaP were ROI grade (grade 5 vs 3, OR 6.5, pbiopsies detected more csCaP (n=289) than targeting (n=229) or systematic biopsy alone (n=199). Among patients with no suspicious ROI, 35 (16%) had csCaP on systematic biopsy. CONCLUSION In this prospective trial, MR-ultrasound fusion biopsy allowed detection of csCaP with a direct relationship with ROI grade and PSA density. The combination of targeted and systematic biopsy detected more csCaP than either modality alone; systematic biopsies revealed csCaP in 16% of men with no suspicious MRI target. Advantages of this new biopsy method are apparent, but issues of cost, training, and reliability await resolution prior to widespread adoption. PMID:26749141

  10. High-risk prostate cancer: value of multi-modality 3T MRI-guided biopsies after previous negative biopsies

    NARCIS (Netherlands)

    Fütterer, J.J.; Verma, S.; Hambrock, T.; Yakar, D.; Barentsz, J.O.

    2012-01-01

    Transrectal ultrasound-guided biopsy is the gold standard for prostate cancer detection. The latter detection rates of random systematic TRUS-guided biopsy do not exceed 44\\%. As a consequence other biopsy methods have been explored. One of these methods is MR-guided biopsy (MRGB), which revealed de

  11. Repeatability of Cryogenic Multilayer Insulation

    Science.gov (United States)

    Johnson, W. L.; Vanderlaan, M.; Wood, J. J.; Rhys, N. O.; Guo, W.; Van Sciver, S.; Chato, D. J.

    2017-01-01

    Due to the variety of requirements across aerospace platforms, and one off projects, the repeatability of cryogenic multilayer insulation has never been fully established. The objective of this test program is to provide a more basic understanding of the thermal performance repeatability of MLI systems that are applicable to large scale tanks. There are several different types of repeatability that can be accounted for: these include repeatability between multiple identical blankets, repeatability of installation of the same blanket, and repeatability of a test apparatus. The focus of the work in this report is on the first two types of repeatability. Statistically, repeatability can mean many different things. In simplest form, it refers to the range of performance that a population exhibits and the average of the population. However, as more and more identical components are made (i.e. the population of concern grows), the simple range morphs into a standard deviation from an average performance. Initial repeatability testing on MLI blankets has been completed at Florida State University. Repeatability of five GRC provided coupons with 25 layers was shown to be +/- 8.4 whereas repeatability of repeatedly installing a single coupon was shown to be +/- 8.0. A second group of 10 coupons have been fabricated by Yetispace and tested by Florida State University, through the first 4 tests, the repeatability has been shown to be +/- 16. Based on detailed statistical analysis, the data has been shown to be statistically significant.

  12. Student-Teachers’ Perception of Feedback Sessions

    OpenAIRE

    González Ramírez, Ana Carolina

    2013-01-01

    In the implementation of an ESP course, post-graduate students receive their supervisors’ opinions in post-observation sessions which tend to be considered troublesome and a “necessary evil.” This study provided tips to 4 participants to improve their experience and thus change their perceptions of feedback sessions into a more enriching and positive experience because student-teachers who hold this view are more effective both as learners and teachers-in-training. Three data-collection instr...

  13. Accuracy Analysis of GNSS Networks Based On Observing-Session Duration in Different Years

    Science.gov (United States)

    Hilmi Erkoç, Muharrem; Doǧan, Uǧur; Aydın, Cüneyt

    2017-04-01

    The aim of this study is to investigate the accuracy of GPS (Global Positioning System) positioning.The observations have been analyzed to determine how the accuracy of derived relative positions of GPS stations depends on the baseline length, the duration of observing session in different years. For this purpose, we selected three days of each year in 2011, 2012 and 2013 from the GPS observations made in CORS-TR Network in Turkey with 15 stations. The GPS observations were processed in the ITRF 2008 reference frame using the Bernese 5.2 GPS software. The baseline length varies between 82 km and 369 km, session duration varies between 4 h and 24 h. The repeatability of the daily solutions belonging to each year was analyzed carefully to scale the Bernese software cofactor matrices. The root mean square (RMS) values for daily repeatability with respect to the combined 3-day solution are computed. The RMS values are less than 3 mm in the horizontal directions (north and east) and < 8 mm in the vertical direction. The results from the investigation agree with the results derived from the previous models in a few mm level. Moreover, a linear relationship between the observing session duration and the accuracy is observed: accuracy for a station decrease when the distance to the fixed station increases. Keywords: Accuracy, GNSS, Session duration, RMS

  14. Retroperitoneoscopic renal biopsy: still a good indication!

    Science.gov (United States)

    Micali, Salvatore; Dandrea, Matteo; De Carne, Cosimo; Martorana, Eugenio; De Stefani, Stefano; Cappelli, Gianni; Bianchi, Giampaolo

    2014-01-01

    The histological evaluation of the renal parenchyma is often essential in cases of several renal diseases and provides useful information in determining the prognosis and guiding treatment. In patients with contraindications to percutaneous kidney biopsy, retroperitoneal laparoendoscopic single-site surgery (LESS) is to be preferred as a minimally invasive technique. However, there are cases in which the LESS technique is difficult to perform, especially given that the learning curve is not optimal. We present a case of a Jehovah's Witness patient with severe obesity, in whom conventional retroperitoneal laparoscopic renal biopsy was preferred to the LESS technique.

  15. Ultrasound-guided diagnostic breast biopsy methodology: retrospective comparison of the 8-gauge vacuum-assisted biopsy approach versus the spring-loaded 14-gauge core biopsy approach

    Science.gov (United States)

    2011-01-01

    Background Ultrasound-guided diagnostic breast biopsy technology represents the current standard of care for the evaluation of indeterminate and suspicious lesions seen on diagnostic breast ultrasound. Yet, there remains much debate as to which particular method of ultrasound-guided diagnostic breast biopsy provides the most accurate and optimal diagnostic information. The aim of the current study was to compare and contrast the 8-gauge vacuum-assisted biopsy approach and the spring-loaded 14-gauge core biopsy approach. Methods A retrospective analysis was done of all ultrasound-guided diagnostic breast biopsy procedures performed by either the 8-gauge vacuum-assisted biopsy approach or the spring-loaded 14-gauge core biopsy approach by a single surgeon from July 2001 through June 2009. Results Among 1443 ultrasound-guided diagnostic breast biopsy procedures performed, 724 (50.2%) were by the 8-gauge vacuum-assisted biopsy technique and 719 (49.8%) were by the spring-loaded 14-gauge core biopsy technique. The total number of false negative cases (i.e., benign findings instead of invasive breast carcinoma) was significantly greater (P = 0.008) in the spring-loaded 14-gauge core biopsy group (8/681, 1.2%) as compared to in the 8-gauge vacuum-assisted biopsy group (0/652, 0%), with an overall false negative rate of 2.1% (8/386) for the spring-loaded 14-gauge core biopsy group as compared to 0% (0/148) for the 8-gauge vacuum-assisted biopsy group. Significantly more (P biopsy group (81/719, 11.3%) than in the 8-gauge vacuum-assisted biopsy group (18/724, 2.5%) were recommended for further diagnostic surgical removal of additional tissue from the same anatomical site of the affected breast in an immediate fashion for indeterminate/inconclusive findings seen on the original ultrasound-guided diagnostic breast biopsy procedure. Significantly more (P biopsy group (54/719, 7.5%) than in the 8-gauge vacuum-assisted biopsy group (9/724, 1.2%) personally requested further

  16. Posters. [Poster Session at AHRD Conference, 2001].

    Science.gov (United States)

    2001

    The first of the papers in this poster session, "Developing the Employment Brand: Targeting MBA Campus Hires" (Diane M. Bergeron), posits that employment branding benefits both individuals and organizations. It functions as a campus recruiting tool in a competitive labor market and communicates the organization's values and work…

  17. Declarative interpretations of session-based concurrency

    DEFF Research Database (Denmark)

    Cano, Mauricio; Rueda, Camilo; López-Acosta, Hugo-Andrés;

    2015-01-01

    Session-based concurrency is a type-based approach to the analysis of communication-intensive systems. Correct behavior in these systems may be specified in an operational or declarative style: the former defines how interactions are structured; the latter defines governing conditions. In this pa...

  18. Organizing a Practice Session for Maximum Effectiveness

    Science.gov (United States)

    DeGroot, Joanna

    2009-01-01

    According to Jason Paulk, director of choral activities at Eastern New Mexico University, progress is made during those in-between times and that progress magnifies with efficient time spent alone. Paulk is a firm believer in the importance of singers organizing their practice sessions, and he details some effective organization methods, including…

  19. My Session With André.

    Science.gov (United States)

    Eigen, Michael

    2015-10-01

    The author shares personal reminiscences of a therapy session with André Green, as well as impressions of professional meetings, readings, and clinical work. He describes personal help he received and aspects of Green's writings on dynamics of madness, as well as the latter's end-of-life discussion of therapeutic limits.

  20. Interpretation of buzzword renxing at Two Sessions

    Institute of Scientific and Technical Information of China (English)

    Ding Xin

    2015-01-01

    A buzzword renxing from Two Sessions has made headlines in domestic and overseas media. Now the word has an authority interpretation--capricious. The interpreter Zhang Lei has become a celebrity overnight. However,according to interpretive theory,thefirst interpretation theory initiated by French translator Danica Seleskovitch,there seems much more room for improving the interpretation of renxing.

  1. An Erlang Implementation of Multiparty Session Actors

    Directory of Open Access Journals (Sweden)

    Simon Fowler

    2016-08-01

    Full Text Available By requiring co-ordination to take place using explicit message passing instead of relying on shared memory, actor-based programming languages have been shown to be effective tools for building reliable and fault-tolerant distributed systems. Although naturally communication-centric, communication patterns in actor-based applications remain informally specified, meaning that errors in communication are detected late, if at all. Multiparty session types are a formalism to describe, at a global level, the interactions between multiple communicating entities. This article describes the implementation of a prototype framework for monitoring Erlang/OTP gen_server applications against multiparty session types, showing how previous work on multiparty session actors can be adapted to a purely actor-based language, and how monitor violations and termination of session participants can be reported in line with the Erlang mantra of "let it fail". Finally, the framework is used to implement two case studies: an adaptation of a freely-available DNS server, and a chat server.

  2. Working session 4: Preventative and corrective measures

    Energy Technology Data Exchange (ETDEWEB)

    Clark, R. [Golder Federal Services Inc., Redmond, WA (United States); Slama, G. [Framatome, Paris (France)

    1997-02-01

    The Preventive and Corrective Measures working session included 13 members from France, Germany, Japan, Spain, Slovenia, and the United States. Attendee experience included regulators, utilities, three steam generator vendors, consultants and researchers. Discussions centered on four principal topics: (1) alternate materials, (2) mechanical mitigation, (3) maintenance, and (4) water chemistry. New or replacement steam generators and original equipment steam generators were separately addressed. Four papers were presented to the session, to provide information and stimulate various discussion topics. Topics discussed and issues raised during the several meeting sessions are provided below, followed by summary conclusions and recommendations on which the group was able to reach a majority consensus. The working session was composed of individuals with diverse experience and varied areas of specialized expertise. The somewhat broad range of topics addressed by the group at times saw discussion participation by only a few individuals. As in any technical meeting where all are allowed the opportunity to speak their mind, straying from an Individual topic was not unusual. Where useful, these stray topics are also presented below within the context In which they occurred. The main categories of discussion were: minimize sludge; new steam generators; maintenance; mechanical mitigation; water chemistry.

  3. Repeated trauma exposure does not impair distress reduction during imaginal exposure for posttraumatic stress disorder.

    Science.gov (United States)

    Jerud, Alissa B; Farach, Frank J; Bedard-Gilligan, Michele; Smith, Hillary; Zoellner, Lori A; Feeny, Norah C

    2017-08-01

    Based on experimental research on threat extinction, individuals exposed to repeated traumatic events may have impaired outcome in exposure therapy compared to those who have experienced a single trauma (Lang & McTeague, ). This study examined whether repeated trauma exposure predicts smaller changes in self-reported distress during imaginal exposure and worse outcomes for patients with posttraumatic stress disorder (PTSD). Adults (N = 116) with chronic PTSD received up to 10 sessions of prolonged exposure (PE) therapy. Trauma exposure was assessed via interview and number of traumatic events were summed for each participant. To examine reductions in distress during treatment, mean and peak values of distress during imaginal exposure were calculated for the first imaginal session (initial distress activation) and subsequent sessions (between-session change in distress). Change in PTSD symptoms from pre- to posttreatment and follow-up provided an additional index of outcome. In-session distress during imaginal exposure decreased over the course of treatment. PTSD symptoms also decreased over treatment, with gains being maintained through follow-up. Repeated trauma exposure was not significantly correlated with initial distress activation. Additionally, linear mixed-model analyses showed no significant association between repeated trauma exposure and between-session change in distress or PTSD symptoms. Contrary to recent speculation, repeated trauma exposure did not predict less change in self-reported distress during imaginal exposure or worse PTSD outcomes. The bench-to-bedside linkage of threat extinction to exposure therapy is discussed, noting strengths and weaknesses. Patients with repeated trauma exposure show reductions in distress with exposure treatment and benefit from PE as much as patients with single-exposure trauma histories. © 2016 Wiley Periodicals, Inc.

  4. Targeted MRI-guided prostate biopsy: are two biopsy cores per MRI-lesion required?

    Energy Technology Data Exchange (ETDEWEB)

    Schimmoeller, L.; Quentin, M.; Blondin, D.; Dietzel, F.; Schleich, C.; Thomas, C.; Antoch, G. [University Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Dusseldorf (Germany); Hiester, A.; Rabenalt, R.; Albers, P.; Arsov, C. [University Dusseldorf, Medical Faculty, Department of Urology, Dusseldorf (Germany); Gabbert, H.E. [University Dusseldorf, Medical Faculty, Department of Pathology, Dusseldorf (Germany)

    2016-11-15

    This study evaluates the feasibility of performing less than two core biopsies per MRI-lesion when performing targeted MR-guided in-bore prostate biopsy. Retrospectively evaluated were 1545 biopsy cores of 774 intraprostatic lesions (two cores per lesion) in 290 patients (66 ± 7.8 years; median PSA 8.2 ng/ml) regarding prostate cancer (PCa) detection, Gleason score, and tumor infiltration of the first (FBC) compared to the second biopsy core (SBC). Biopsies were acquired under in-bore MR-guidance. For the biopsy cores, 491 were PCa positive, 239 of 774 (31 %) were FBC and 252 of 771 (33 %) were SBC (p = 0.4). Patient PCa detection rate based on the FBC vs. SBC were 46 % vs. 48 % (p = 0.6). For clinically significant PCa (Gleason score ≥4 + 3 = 7) the detection rate was 18 % for both, FBC and SBC (p = 0.9). Six hundred and eighty-seven SBC (89 %) showed no histologic difference. On the lesion level, 40 SBC detected PCa with negative FBC (7.5 %). Twenty SBC showed a Gleason upgrade from 3 + 3 = 6 to ≥3 + 4 = 7 (2.6 %) and 4 to ≥4 + 3 = 7 (0.5 %). The benefit of a second targeted biopsy core per suspicious MRI-lesion is likely minor, especially regarding PCa detection rate and significant Gleason upgrading. Therefore, a further reduction of biopsy cores is reasonable when performing a targeted MR-guided in-bore prostate biopsy. (orig.)

  5. Poster Sessions in Marketing Education: An Empirical Examination

    Science.gov (United States)

    Stegemann, Nicole; Sutton-Brady, Catherine

    2009-01-01

    Poster sessions provide a creative and stimulating alternative to traditional assessment methods in marketing. Poster sessions, as a means of assessment, have long been used in science fields. This article presents the successful implementation of poster sessions as a means of assessment in a postgraduate unit of study. Poster sessions in…

  6. Poster Sessions in Marketing Education: An Empirical Examination

    Science.gov (United States)

    Stegemann, Nicole; Sutton-Brady, Catherine

    2009-01-01

    Poster sessions provide a creative and stimulating alternative to traditional assessment methods in marketing. Poster sessions, as a means of assessment, have long been used in science fields. This article presents the successful implementation of poster sessions as a means of assessment in a postgraduate unit of study. Poster sessions in…

  7. Clinical role of the renal transplant biopsy

    Science.gov (United States)

    Williams, Winfred W.; Taheri, Diana; Tolkoff-Rubin, Nina; Colvin, Robert B.

    2013-01-01

    Percutaneous needle core biopsy is the definitive procedure by which essential diagnostic and prognostic information on acute and chronic renal allograft dysfunction is obtained. The diagnostic value of the information so obtained has endured for over three decades and has proven crucially important in shaping strategies for therapeutic intervention. This Review provides a broad outline of the utility of performing kidney graft biopsies after transplantation, highlighting the relevance of biopsy findings in the immediate and early post-transplant period (from days to weeks after implantation), the first post-transplant year, and the late period (beyond the first year). We focus on how biopsy findings change over time, and the wide variety of pathological features that characterize the major clinical diagnoses facing the clinician. This article also includes a discussion of acute cellular and humoral rejection, the toxic effects of calcineurin inhibitors, and the widely varying etiologies and characteristics of chronic lesions. Emerging technologies based on gene expression analyses and proteomics, the in situ detection of functionally relevant molecules, and new bioinformatic approaches that hold the promise of improving diagnostic precision and developing new, refined molecular pathways for therapeutic intervention are also presented. PMID:22231130

  8. Personalized cancer medicine guided by liquid biopsies

    NARCIS (Netherlands)

    N. Beije (Nick)

    2017-01-01

    markdownabstractThe capacity to optimally treat cancer patients is nowadays challenged by several factors. These challenges are particularly caused by tumor heterogeneity and plasticity, causing tumor characteristics to change over time and under treatment pressure. The use of liquid biopsies sample

  9. Histopathological study of cystoscopic bladder biopsies

    Directory of Open Access Journals (Sweden)

    R Baidya

    2015-03-01

    Full Text Available Background: Urinary bladder diseases constitute an important source of clinical signs and symptoms which are more disabling than lethal. The prevalence of bladder tumor in developed countries is approximately six times higher compared with that in developing countries. The aim of this study was to find out various lesions in urinary bladder biopsies and its frequencies.Materials and Methods: This was a five year retrospective study from January 2008 to December 2013, carried out at B&B Hospital, Lalitpur. All the relevant data of 324 patients who had undergone cystoscopic biopsy of urinary bladder were included in the study. All blocks were retrieved and stained with Hematoxylin and Eosin stain and examined under light microscope.Results: The spectrum of pathological lesions included inflammations and tumors. Non-neoplastic lesions were predominant (61.11% followed by Transitional cell tumors accounted for 124 cases (38.27%. Non-neoplastic lesions comprises of cystitis and tuberculosis. Papillary urothelial neoplasms was the most common tumors seen in this study with 55 low grade, and 54 high grade Papillary urothelial carcinoma according to recent WHO grading. Single cases each of adenocarcinoma and paraganglioma were diagnosed.Conclusion: Cystoscopic biopsies help in the early diagnosis and treatment of various bladder lesions. Analysis of cystoscopic biopsies was done to ascertain the type of urinary bladder lesions in our country.Journal of Pathology of Nepal (2015 Vol. 5, 717-719

  10. Core biopsies of the breast: Diagnostic pitfalls

    Directory of Open Access Journals (Sweden)

    Megha Joshi

    2011-01-01

    Full Text Available The incidence of breast cancer is increasing worldwide. In this review article, the authors compare and contrast the incidence of breast cancer, and the inherent differences in the United States (US and India in screening techniques used for diagnosing breast cancer. In spite of these differences, core biopsies of the breast are common for diagnosis of breast cancer in both countries. The authors describe "Best Practices" in the reporting and processing of core biopsies and in the analysis of estrogen receptor (ER, progesterone receptor (PR, and human epidermal growth factor Receptor 2 (Her2/neu. The pitfalls in the diagnosis of fibroepithelial lesions of the breast on core biopsy are discussed, as also the significance of pseudoangiomatous stromal hyperplasia of the breast (PASH is discussed in core biopsy. In this review, the management and diagnosis of flat epithelial atypia and radiation atypia are elaborated and the use of immunohistochemistry (IHC in papillary lesions, phyllodes tumor, and complex sclerosing lesions (radial scars is illustrated. Rarer lesions such as mucinous and histiocytoid carcinoma are also discussed.

  11. Liver biopsy in liver patients with coagulopathy

    DEFF Research Database (Denmark)

    Ott, P.; Gronbaek, H.; Clausen, M.R.

    2008-01-01

    The risk of severe bleeding after liver biopsy is estimated to be 1:12,000 in patients with near normal coagulation (INR 60 billion /l). Beyond these limits, the risk is higher, but still uncertain. The Danish guidelines require INR > 1.5, platelet count

  12. Endoscopic biopsy: Duodenal ulcer penetrating into liver

    Institute of Scientific and Technical Information of China (English)

    Baybora Kircali; Tülay Saricam; Aysegul Ozakyol; Eser Vardareli

    2005-01-01

    @@ TO THE EDITOR We have read with interest the recent report by E Kayacetin and S Kayacetin of Gastric ulcer penetrating to liver diagnosed by endoscopic biopsy[1] since we diagnosed the duodenal ulcer which penetrated into liver similarly. This is a rather unusual case because of the fifth case in the literature and responding to medical therapy.

  13. Study of prostate biopsy robot system

    Institute of Scientific and Technical Information of China (English)

    ZHANG Yong-de; ZHANG Long; ZHAO Yan-jiang; ZHANG Yan-hua

    2009-01-01

    A system for prostate biopsy with robot assistance was proposed. The system consists of Motoman robot, needle insertion mechanism, and control software. A experiment was held with this software, and it proved that the whole system is simple, reliable and good application.

  14. Biopsy of Brainstem Gliomas Using Flexible Endoscopes.

    Science.gov (United States)

    Torres-Corzo, Jaime Gerardo; Sanchez-Rodriguez, Jose; Castillo-Rueda, Juan Lucino; Falcon-Escobedo, Reynaldo; Cervantes, Dominic; Rodriguez-Della Vecchia, Roberto; Vinas-Rios, Juan Manuel

    2015-07-01

    To describe our experience and the results obtained in performing transventricular brainstem biopsy with the use of flexible neuroendoscops. We identified patients who underwent a neuroendoscopic procedure with brainstem lesion biopsy to obtain histopathologic diagnosis and to treat obstructive hydrocephalus. All patients had follow-up examinations at months 1, 3, 6, and 12 postsurgery and then annually. Seven patients had a transventricular biopsy of the brainstem performed. Of those, five were pediatric patients. The median age was 10 years (range: 3-26 years). Five of them were female and two male. Four patients presented with secondary obstructive hydrocephalus. The main clinical presentations were intracranial hypertension syndrome in four patients, motor neuron disease in four patients, two with decreased state of alertness, two with gait ataxia, and one with Parinaud syndrome. The types of tumors found in the histopathology and their location were one ventral (pons) and one aqueductal anaplastic astrocytoma, two ventral, one aqueductal, and one attached to the floor of the fourth ventricle pilocytic astrocytoma and one ventral low-grade astrocytoma. The route taken to approach the ventral tumors was made through premammillary fenestration. The tumors of the aqueduct and floor of the fourth ventricle were approached transaqueductally. The use of flexible endoscops for biopsy of ventral, dorsal (tectum lamina quadrigemina), and diffuse brainstem tumors is a useful, effective, and safe procedure that also allows to treat obstructive hydrocephalus secondary to the tumors. Georg Thieme Verlag KG Stuttgart · New York.

  15. Personalized cancer medicine guided by liquid biopsies

    NARCIS (Netherlands)

    N. Beije (Nick)

    2017-01-01

    markdownabstractThe capacity to optimally treat cancer patients is nowadays challenged by several factors. These challenges are particularly caused by tumor heterogeneity and plasticity, causing tumor characteristics to change over time and under treatment pressure. The use of liquid biopsies sample

  16. Reducing infection rates after prostate biopsy.

    Science.gov (United States)

    Wagenlehner, Florian M E; Pilatz, Adrian; Waliszewski, Przemyslaw; Weidner, Wolfgang; Johansen, Truls E Bjerklund

    2014-02-01

    Over the years, prostate biopsy has become the gold-standard technique for diagnosing prostate carcinoma. Worldwide, several million prostate biopsies are performed every year, most commonly using the transrectal approach. Preoperative antibiotic prophylaxis with fluoroquinolones has been shown to be effective for reducing infection rates. However, in recent years, an increase in febrile infection rates after transrectal prostate biopsy (from 1% to 4%) has been reported in retrospective and prospective studies. The predominant risk factor for infection seems to be the presence of fluoroquinolone-resistant bacteria in faeces. Patients at risk of fluoroquinolone resistance should receive carefully selected antibiotics at sufficient concentrations to be effective. Targeted prophylaxis after rectal flora swabbing has been shown to be efficacious compared with empirical antibiotic prophylaxis. Several forms of bowel preparations are under investigation, although none have yet been shown to significantly reduce infection rates. Perineal prostate biopsy is currently being evaluated as a strategy for preventing the inoculation of rectal flora, but limited data support this approach at present.

  17. Systematic kidney biopsies after acute allograft pyelonephritis.

    Science.gov (United States)

    Cartery, Claire; Guilbeau-Frugier, Céline; Esposito, Laure; Sallusto, Federico; Guitard, Joelle; Cardeau-Desangles, Isabelle; Cointault, Olivier; Game, Xavier; Rostaing, Lionel; Kamar, Nassim

    2013-06-01

    Scarce data exist regarding the effect of acute graft pyelonephritis on kidney histology after a kidney transplant. This study sought to assess the kidney histology at 1 month, and kidney function at 1 year, after acute graft pyelonephritis in kidney transplant patients. All kidney transplant patients with acute graft pyelonephritis between October 2006, and December 2008, underwent a kidney biopsy 1 month later (n=28). Histologic findings were compared with those observed in a control group (n=28) who underwent a protocol kidney biopsy at 1 year posttransplant and did not present with acute graft pyelonephritis. Patients were matched according to age, sex, and immunosuppressive regimen. Kidney function was impaired by the acute graft pyelonephritis episodes at the time of biopsy. In 40% of patients, the estimated glomerular filtration rate did not return to baseline by 1 month after acute graft pyelonephritis and remained impaired thereafter. Three patients had features of acute rejection. Tubulitis was seen more frequently in the acute graft pyelonephritis group, especially in patients in whom estimated glomerular filtration rate did not completely recover by 1 month after acute graft pyelonephritis. Patients with acute graft pyelonephritis who had inflammatory infiltrate of > 20% 1 month after acute graft pyelonephritis had worse kidney function 1 year later. After transplant, when kidney function remains impaired 1 month after acute graft pyelonephritis, kidney biopsies allowed graft rejection diagnosis and predicted kidney function recovery.

  18. Psychiatric disorder associated with vacuum-assisted breast biopsy clip placement: a case report

    Directory of Open Access Journals (Sweden)

    Zografos George C

    2008-10-01

    Full Text Available Abstract Introduction Vacuum-assisted breast biopsy is a minimally invasive technique that has been used increasingly in the treatment of mammographically detected, non-palpable breast lesions. Clip placement at the biopsy site is standard practice after vacuum-assisted breast biopsy. Case presentation We present the case of a 62-year-old woman with suspicious microcalcifications in her left breast. The patient was informed about vacuum-assisted breast biopsy, including clip placement. During the course of taking the patient's history, she communicated excellently, her demeanor was normal, she disclosed no intake of psychiatric medication and had not been diagnosed with any psychiatric disorders. Subsequently, the patient underwent vacuum-assisted breast biopsy (11 G under local anesthesia. A clip was placed at the biopsy site. The pathological diagnosis was of sclerosing adenosis. At the 6-month mammographic follow-up, the radiologist mentioned the existence of the metallic clip in her breast. Subsequently, the woman presented complaining about "being spied [upon] by an implanted clip in [her] breast" and repeatedly requested the removal of the clip. The patient was referred to the specialized psychiatrist of our breast unit for evaluation. The Mental State Examination found that systematized paranoid ideas of persecutory type dominated her daily routines. At the time, she believed that the implanted clip was one of several pieces of equipment being used to keep her under surveillance, the other equipment being her telephone, cameras and television. Quite surprisingly, she had never had a consultation with a mental health professional. The patient appeared depressed and her insight into her condition was impaired. The prevalent diagnosis was schizotypal disorder, whereas the differential diagnosis comprised delusional disorder of persecutory type, affective disorder with psychotic features or comorbid delusional disorder with major depression

  19. Motion sickness severity and physiological correlates during repeated exposures to a rotating optokinetic drum

    Science.gov (United States)

    Hu, Senqi; Grant, Wanda F.; Stern, Robert M.; Koch, Kenneth L.

    1991-01-01

    Fifty-two subjects were exposed to a rotating optokinetic drum. Ten of these subjects who became motion sick during the first session completed two additional sessions. Subjects' symptoms of motion sickness, perception of self-motion, electrogastrograms (EGGs), heart rate, mean successive differences of R-R intervals (RRI), and skin conductance were recorded for each session. The results from the first session indicated that the development of motion sickness was accompanied by increased EGG 4-9 cpm activity (gastric tachyarrhythmia), decreased mean succesive differences of RRI, increased skin conductance levels, and increased self-motion perception. The results from the subjects who had three repeated sessions showed that 4-9 cpm EGG activity, skin conductance levels, perception of self-motion, and symptoms of motion sickness all increased significantly during the drum rotation period of the first session, but increased significantly less during the following sessions. Mean successive differences of RRI decreased significantly during the drum rotation period for the first session, but decreased significantly less during the following sessions. Results show that the development of motion sickness is accompanied by an increase in gastric tachyarrhythmia, and an increase in sympathetic activity and a decrease in parasympathetic activity, and that adaptation to motion sickness is accompanied by the recovery of autonomic nervous system balance.

  20. ASCO Plenary Sessions: impact, legacy, future.

    Science.gov (United States)

    Vandross, Andrae; Prasad, Vinay; Mailankody, Sham

    2016-06-01

    The ASCO annual meeting draws a large crowd of physicians, cancer researchers, policy makers, and industry representatives. The crown jewel of the annual events is the Plenary session where impactful, influential and visible abstracts are selected for the largest audience. Plenary topics are frequently paired with concurrent New England Journal or Lancet publications.  Here, we review 9 years of ASCO plenary sessions.  Several themes emerge.  First, many of the topics selected have indeed been practice changing, such as the use of ALK inhibitors for ALK rearranged NSCLC, or checkpoint inhibitors in metastatic melanoma.  Second, although some plenary topics seemed destined to change practice, they ultimately falter, such as the use of Cetuximab in NSCLC, vaccine therapy for follicular lymphoma, and even Bevacizumab in metastatic renal cell cancer. Who could have forseen bevacizumab displaced by several VEGF TKIs?  Third, negative trials are rare among Plenary sessions, but when they are presented they are immensely important.  Examples include a seminal study using CA-125 levels to guide treatment of relapsed ovarian cancer, the use of lapatinib combined with traztuzumab in the adjuvant treatment of HER2 + disease, and studies showing no survival benefit to upfront bevacizumab in glioblastoma multiforme.   Fourth, we note a large industry presence among Plenary sessions, as the Industry in part sponsored 62% of Plenary abstracts.  Ultimately a review of 9 years of ASCO plenary reveals the plenary for what it is: a conservative selection of abstracts that, at the time, are thought to change the face of oncology.  Time, however, is the true arbiter, and some succeed in this quest, while others falter.  ASCO plenary sessions reveal the influence, legacy and future of cancer care.

  1. EFFICACY OF IMMUNOHISTOCHEMISTRY IN PROSTATE NEEDLE BIOPSIES

    Directory of Open Access Journals (Sweden)

    Tameem Afroz

    2016-10-01

    Full Text Available BACKGROUND Prostate needle biopsies can pose a major diagnostic challenge when it comes to differentiating adenocarcinoma and its variants from its benign mimics. In needle biopsies, when the suspicious focus is small, morphological features may not suffice to differentiate it from its morphologic mimics like atrophy, basal cell hyperplasia, reactive inflammatory changes, seminal vesicles and adenosis. Immunohistochemical marker for basal cells, p63 and prostate cancer specific marker, Alpha-Methylacyl-CoA Racemase (AMACR help in overcoming such diagnostic dilemmas. MATERIALS AND METHODS We analysed 157 prostate core needle biopsies over a period of 2 years. Routine Hematoxylin and Eosin (H and E sections and immunohistochemical markers for basal cells (p63 and prostate cancer specific marker (AMACR were used. Prospective study was done on prostate needle core biopsies. Biopsy was done under ultrasound guidance with an 18-gauge needle. Biopsy was done in patients with raised serum PSA levels for exclusion of prostate carcinoma. RESULTS Over a period of two years, 157 prostate core needle biopsies were studied. 83 were benign lesions comprising 69 benign prostatic hyperplasias, five basal cell hyperplasias, four granulomatous lesions and three showed atrophic changes. Two biopsies morphologically resembled seminal vesicles. Prostate cancer specific marker, AMACR was negative in all, but two lesions. In these two lesions, it showed weak nonspecific staining. Basal cell marker p63 showed a continuous staining pattern highlighting the basal cells in all the 69 cases of benign prostatic hyperplasia, 5 cases of basal hyperplasia showed positivity in all the hyperplastic basal cells. In the two cases of seminal vesicles, it showed intense basal cell positivity. It showed a discontinuous pattern in two of the four granulomatous lesions and showed a weak, but a continuous staining pattern in the atrophic lesions. 74 were adenocarcinomas; the predominant

  2. Positive predictive value of high-grade prostatic intraepithelial neoplasia in initial core needle biopsies of prostate adenocarcinoma--a study with complete sampling of hemi-prostates with corresponding negative biopsy findings.

    Science.gov (United States)

    Delatour, Nicolas L D Roustan; Mai, Kien T

    2008-09-01

    High-grade prostatic intraepithelial neoplasia (HGPIN) is a putative premalignant lesion of prostate adenocarcinoma (PCa). The significance of isolated HGPIN in initial biopsy cores as a marker of PCa in repeat biopsies has been extensively investigated, but little is known of the true occurrence of PCa in this setting, because repeat biopsies can miss the focus of cancer. In this study, a hemi-prostate model was used to define the true positive predictive value of HGPIN in core biopsies in predicting PCa. From 132 consecutive resected prostate specimens, 70 hemi-prostates with all corresponding biopsy cores negative for PCa were thoroughly examined. Of the 70 hemi-prostates, 38 had PCa (including 8 with clinically significant PCa), and 11 had HGPIN. In the group of 38 hemi-prostate with PCa, 7 were associated with HGPIN-positive biopsies. No statistically significant difference was found between the hemi-prostates with or without PCa, regarding the presence, microscopic pattern, or multiple core involvement of HGPIN in the biopsies. The positive predictive value of HGPIN in predicting for clinically significant PCa was 27%, the negative predictive value was 87%, the sensitivity was 38%, and the specificity was 91% (P = 0.04, statistically significant). In addition, the positive predictive value of multiple cores with HGPIN in predicting for clinically significant PCa was 75% (negative predictive value 92%). The results of the present study have failed to support HGPIN as a statistically significant predictor for the occurrence of PCa. More importantly, however, HGPIN and multiple core involvement did seem to be a useful marker for clinically significant PCa.

  3. The effect of repeated measurements and working memory on the most comfortable level in the ANL test

    DEFF Research Database (Denmark)

    Brännström, K Jonas; Olsen, Steen Østergaard; Holm, Lucas

    2014-01-01

    interleaved methodology during one session using a non-semantic version. Phonological (PWM) and visuospatial working memory (VSWM) was measured. STUDY SAMPLE: Thirty-two normal-hearing adults. RESULTS: Repeated measures ANOVA, intraclass correlations, and the coefficient of repeatability (CR) were used...

  4. The role of feedback and differences between good and poor decoders in a repeated word reading paradigm in first grade

    NARCIS (Netherlands)

    Gorp, K. van; Segers, P.C.J.; Verhoeven, L.T.W.

    2017-01-01

    The direct, retention, and transfer effects of repeated word and pseudoword reading were studied in a pretest, training, posttest, retention design. First graders (48 good readers, 47 poor readers) read 25 CVC words and 25 CVC pseudowords in ten repeated word reading sessions, preceded and followed

  5. Session-RPE for quantifying load of different youth taekwondo training sessions.

    Science.gov (United States)

    Lupo, Corrado; Capranica, Laura; Cortis, Cristina; Guidotti, Flavia; Bianco, Antonino; Tessitore, Antonio

    2017-03-01

    The session rating of perceived exertion (session-RPE) proved to be a valuable method to quantify the internal training load (ITL) in taekwondo. However, no study validated this method in youth taekwondo athletes performing different training sessions. Thus this study aimed at evaluating the reliability of the session-RPE to monitor the ITL of prepubescent taekwondo athletes during pre-competitive (PC) and competitive (C) training sessions. Five female (age: 12.0±0.7 y; height: 1.54±0.08 m; body mass: 48.8±7.3 kg) and four male (age: 12.0±0.8 yrs; height: 1.55±0.07 m; body mass: 47.3±5.3 kg) taekwondo athletes were monitored during 100 individual sessions (PC: N.=33; C: N.=67). The Edwards' HR method was used as reference measure of ITL; the CR-10 RPE scale was administered at 1- and 30-minutes from the end of each session. No difference for gender emerged. The ITLs of C (Edwards: 228±40 arbitrary units, AU) resulted higher than that of PC (192±26 AU; P=0.04). Although all training typologies and data collections achieved significant correlations between Edwards' and session-RPE methods, a large relationship (r =0.71, Ptaekwondo athletes to successfully use session-RPE to monitor the ITL of different training typologies. However, PC training evaluated at 30 minutes of the recovery phase represents the best condition for a highly reliable ITL perception.

  6. Neuromuscular and Blood Lactate Response After a Motocross Training Session in Amateur Riders

    Directory of Open Access Journals (Sweden)

    Simões

    2016-03-01

    Full Text Available Background Motocross is one of the most popular motorized off-road sports, characterized by riding on irregular natural terrain of hard earth and/or sand with various obstacles throughout the course. Objectives This study evaluated the influence of a motocross training session on neuromuscular response and blood lactate in amateur riders. Patients and Methods Nine motocross riders (22.7 ± 2.8 years participating in amateur competitions at the state level conducted a training session of 20 minutes duration at a motocross track (1.6 km with a 250-cc four-stroke motorcycle. Metabolic demand was measured with blood lactate concentrations before and immediately, 3, 5, 8, and 10 minutes after the training session. To measure neuromuscular response, riders completed handgrip strength and horizontal jump tests before and 10 minutes after the training session. Student’s t-test and analysis of variance one-way repeated measures were used to compare the changes before and after the motocross training session. Results Significant decreases in handgrip strength were observed for both hands (left: P = 0.010 and right: P = 0.004. However, no significant difference (P = 0.241 in horizontal jump ability was observed. Significant blood lactate values were observed immediately (P = 0.001, 3 (P = 0.001, 5 (P = 0.001, and 8 (P = 0.01 minutes after training when compared to the value before training. The peak blood lactate value was 6.5 ± 2.7 mM at 8 minutes after the training session. Conclusions Amateur motocross riders had significant anaerobic metabolism demands and had reduced handgrip strength following a training session. These data suggest an importance of physical training aimed at improving anaerobic and neuromuscular performance of the upper limbs in amateur motocross riders.

  7. Neuromuscular and Blood Lactate Response After a Motocross Training Session in Amateur Riders.

    Science.gov (United States)

    Simões, Vinicius Radenzev; Crisp, Alex Harley; Verlengia, Rozangela; Pellegrinotti, Idico Luiz

    2016-06-01

    Motocross is one of the most popular motorized off-road sports, characterized by riding on irregular natural terrain of hard earth and/or sand with various obstacles throughout the course. This study evaluated the influence of a motocross training session on neuromuscular response and blood lactate in amateur riders. Nine motocross riders (22.7 ± 2.8 years) participating in amateur competitions at the state level conducted a training session of 20 minutes duration at a motocross track (1.6 km) with a 250-cc four-stroke motorcycle. Metabolic demand was measured with blood lactate concentrations before and immediately, 3, 5, 8, and 10 minutes after the training session. To measure neuromuscular response, riders completed handgrip strength and horizontal jump tests before and 10 minutes after the training session. Student's t-test and analysis of variance one-way repeated measures were used to compare the changes before and after the motocross training session. Significant decreases in handgrip strength were observed for both hands (left: P = 0.010 and right: P = 0.004). However, no significant difference (P = 0.241) in horizontal jump ability was observed. Significant blood lactate values were observed immediately (P = 0.001), 3 (P = 0.001), 5 (P = 0.001), and 8 (P = 0.01) minutes after training when compared to the value before training. The peak blood lactate value was 6.5 ± 2.7 mM at 8 minutes after the training session. Amateur motocross riders had significant anaerobic metabolism demands and had reduced handgrip strength following a training session. These data suggest an importance of physical training aimed at improving anaerobic and neuromuscular performance of the upper limbs in amateur motocross riders.

  8. Effects of repeated collaborative retrieval on individual memory vary as a function of recall versus recognition tasks.

    Science.gov (United States)

    Blumen, Helena M; Rajaram, Suparna

    2009-11-01

    Our research examines how prior group collaboration modulates later individual memory. We recently showed that repeated collaborative recall sessions benefit later individual recall more than a single collaborative recall session (Blumen & Rajaram, 2008). Current research compared the effects of repeated collaborative recall and repeated collaborative recognition on later individual recall and later individual recognition. A total of 192 participants studied a list of nouns and then completed three successive retrieval sessions in one of four conditions. While two collaborative recall sessions and two collaborative recognition sessions generated comparable levels of individual recall (CRecall-CRecall-I Recall approximately CRecognition-CRecognition-I Recall , Experiment 1a), two collaborative recognition sessions generated greater levels of individual recognition than two collaborative recall sessions (CRecognition-CRecognition- IRecognition > CRecall-CRecall- I Recognition , Experiment 1b). These findings are discussed in terms of two opposing mechanisms that operate during collaborative retrieval-re-exposure and retrieval disruption-and in terms of transfer-appropriate processing across collaborative and individual retrieval sessions.

  9. Protein intake during training sessions has no effect on performance and recovery during a strenuous training camp for elite cyclists

    DEFF Research Database (Denmark)

    Hansen, Mette; Bangsbo, Jens; Jensen, Jørgen

    2016-01-01

    ). Diet and training were standardized and supervised. The diet was energy balanced and contained 1.7 g protein/kg/day. A 10-s peak power test and a 5-min all-out performance test were conducted before and after the first training session and repeated at day 6 of the camp. Blood and saliva samples were...... during cycling at a training camp for top cyclists did not result in marked performance benefits compared to intake of carbohydrates when a recovery drink containing adequate protein and carbohydrate was ingested immediately after each training session in both groups. These findings suggest...... sessions is generally accepted as being beneficial to aid performance and recovery, whereas the effect of protein supplementation and timing is less well understood. We studied the effects of protein ingestion during training sessions on performance and recovery of elite cyclists during a strenuous...

  10. Complications of percutaneous renal tumor biopsy: An analysis of 340 consecutive biopsies

    DEFF Research Database (Denmark)

    René Rasmussen, Lars; Loft, Martina; Høyer, Søren;

    Purpose Ultrasound Guided Percutaneous Kidney Biopsy (UGPKB) plays a major role in diagnosis of renal tumours. There seems to be little consensus regarding post-biopsy observation period. We aim to identify complications in UGPKB among outpatients with a suspected malignant renal lesion as well...... as the timing of onset of these complications, helping to clarify the optimal observation period. Many studies in this field suggest a lower complication risk for outpatients compared to hospitalized patients. In the latter group, an observation period of 24h after biopsy is often recommended. Material...... discrepancy. Results As for one third of the patients, analysed up until now, we find a total of one major complication and a few minor, all arisen within less than 6 hours after biopsy. Conclusions Rates of both major and minor complications in UGPKB are very low suggesting a shorter observation period...

  11. Feasibility of fine-needle aspiration biopsy and its applications in superficial cervical lesion biopsies.

    Science.gov (United States)

    Xu, Dong; Xu, Hai-Miao; Li, Ming-Kui; Chen, Li-Yu; Wang, Li-Jing

    2014-01-01

    The aim of the study was to investigate the feasibility and value of clinical application of fine-needle aspiration histological biopsy via ultrasound-guided thyroid nodule and enlarged cervical lymph node fine-needle aspiration histological biopsy. Fine-needle aspiration cytological and histological biopsies and surgical treatments were performed on 982 patients with thyroid nodule and 1435 patients with enlarged cervical lymph nodes. A comparative study of the histological and cytological examination results and post-surgical etiology results was subsequently conducted. Among the 982 thyroid nodule patients, the acquisition rates were 89.8% (882/982) for fine-needle aspiration histological biopsy and 96.2% (945/982) for cytological biopsy, while among the 1435 patients with enlarged cervical lymph nodes, the acquisition rate for fine-needle aspiration cytological biopsy was slightly higher than that for histological biopsy, with values of 95.7% (1374/1435) and 91.4% (1312/1435), respectively. For the thyroid nodule patients, when the acquired histological and cytological biopsy results were compared with the post-surgical etiology results, the sensitivity, specificity, and accuracy of the histological results were 98.5%, 100%, and 98.9%, respectively, whereas those of the cytological results were 86.8%, 82.9%, and 85.6%, respectively; the differences between the 2 biopsy methods were statistically significant (P < 0.05). For the patients with enlarged cervical lymph nodes, when the acquired histological and cytological biopsy results were compared with the post-surgical etiology results, the sensitivity, specificity, and accuracy of the histological results were 96.3%, 99.8%, and 97.6%, respectively, whereas the those of the cytological results were 76.8%, 92.1%, and 82.2%, respectively; again, the differences between the 2 methods were statistically significant (P < 0.05). In conclusion, Fine-needle aspiration histological biopsy is a reliable and highly

  12. Molecular image-directed biopsies: improving clinical biopsy selection in patients with multiple tumors

    Science.gov (United States)

    Harmon, Stephanie A.; Tuite, Michael J.; Jeraj, Robert

    2016-10-01

    Site selection for image-guided biopsies in patients with multiple lesions is typically based on clinical feasibility and physician preference. This study outlines the development of a selection algorithm that, in addition to clinical requirements, incorporates quantitative imaging data for automatic identification of candidate lesions for biopsy. The algorithm is designed to rank potential targets by maximizing a lesion-specific score, incorporating various criteria separated into two categories: (1) physician-feasibility category including physician-preferred lesion location and absolute volume scores, and (2) imaging-based category including various modality and application-specific metrics. This platform was benchmarked in two clinical scenarios, a pre-treatment setting and response-based setting using imaging from metastatic prostate cancer patients with high disease burden (multiple lesions) undergoing conventional treatment and receiving whole-body [18F]NaF PET/CT scans pre- and mid-treatment. Targeting of metastatic lesions was robust to different weighting ratios and candidacy for biopsy was physician confirmed. Lesion ranked as top targets for biopsy remained so for all patients in pre-treatment and post-treatment biopsy selection after sensitivity testing was completed for physician-biased or imaging-biased scenarios. After identifying candidates, biopsy feasibility was evaluated by a physician and confirmed for 90% (32/36) of high-ranking lesions, of which all top choices were confirmed. The remaining cases represented lesions with high anatomical difficulty for targeting, such as proximity to sciatic nerve. This newly developed selection method was successfully used to quantitatively identify candidate lesions for biopsies in patients with multiple lesions. In a prospective study, we were able to successfully plan, develop, and implement this technique for the selection of a pre-treatment biopsy location.

  13. Differences in pain perception during open muscle biopsy and Bergstroem needle muscle biopsy

    OpenAIRE

    Dengler J; Linke P; Gdynia HJ; Wolf S.; Ludolph AC; Vajkoczy P; Meyer T

    2014-01-01

    Julius Dengler,1 Peter Linke,2 Hans J Gdynia,3 Stefan Wolf,1 Albert C Ludolph,3 Peter Vajkoczy,1 Thomas Meyer2 1Department of Neurosurgery, 2Department of Neurology, Charité – Universitätsmedizin Berlin, Berlin, Germany; 3Department of Neurology, Universitätsklinikum Ulm, Ulm, GermanyPurpose: Open surgical muscle biopsy (OB) and percutaneous Bergstroem needle muscle biopsy (NB) are equally accepted procedures. However, there are no data comparing intrapr...

  14. CT-guided bone biopsy: Initial experience with a commercially available hand held Black and Decker{sup TM} drill

    Energy Technology Data Exchange (ETDEWEB)

    Buckley, O. [Department of Radiology, Adelaide and Meath, Hospital, Tallaght, Dublin 24 (Ireland); Benfayed, W. [Department of Radiology, Adelaide and Meath, Hospital, Tallaght, Dublin 24 (Ireland); Geoghegan, T. [Department of Radiology, Adelaide and Meath, Hospital, Tallaght, Dublin 24 (Ireland); Al-Ismail, K. [Department of Radiology, King Faisal Hospital (Saudi Arabia); Munk, P.L. [Department of Radiology, Musculo-Skeletal division, Vancouver General Hospital, 899 W. 12th Ave., Vancouver, BC V5Z 1M9 (Canada); Torreggiani, William C. [Department of Radiology, Adelaide and Meath, Hospital, Tallaght, Dublin 24 (Ireland)]. E-mail: william.torreggiani@amnch.ie

    2007-01-15

    Purpose: To describe the use of a simple commercially available Black and Decker{sup TM} hand based drill in performing CT-guided bone biopsies. Materials and methods: Three international institutions were enrolled in the study. In each centre, a fellowship trained musculoskeletal radiologist directed the assessment of a hand based commercial drill for performing CT-guided bone biopsies. A specially designed component was engineered which allowed the connection of a standard bone biopsy set to a commercial drill. The component was distributed to the three centres involved. Over a 3-year period, data from all three institutions was collected. Information regarding technical success, diagnostic data and complication rates were all collated to assess the technical feasibility of this technique. Results: In total 68 patients underwent bone biopsy using a hand held commercial drill. Technical success was achieved in 65 patients. Diagnostic material was obtained in 53 patients. Non-diagnostic material was obtained in 12 patients. Five out of the 12 patients with non-diagnostic material had repeat biopsies with diagnostic material obtained in 2 of these. No major complications occurred in any patient. Conclusion: CT-guided bone biopsy using a hand held commercial drill has a technically high success rate with minimal complications.

  15. RELEVANCE OF ARTHROSCOPIC SYNOVIAL BIOPSY IN JOINT DISORDERS - A PROSPECTIVE STUDY

    Directory of Open Access Journals (Sweden)

    Kali Vara Prasad

    2015-10-01

    Full Text Available BACK GROUND : Synovial biopsy is considered as the gold standard in the diagnosis of various joint disorders and synovial diseases. But sometimes the definitive diagnosis is elusive only by doing biopsy then clinical, hematological and x - ray examinations will help. The advantage with arthroscopic synovial biopsy is that it is easy to perform, minimal discomfort to the patient and can be done at intervals if the diagnosis can n ot be made in the first examination. MATERIAL & METHODS : The present study was conducted in the Department of Orthopedics & Traumatology, Osmania General Hospital/ Medical College, Hyderabad. The duration of the study was from Sept 2012 to Sept 2014. CONCLUSIONS : Arthroscopic synovial biopsy is the mainstay in the management of Joint disorders and Synovial diseases. It is patient friendly and repeated procedures can be undertaken when the definitive diagnosis could not be established in the initial attempt, as is common in some cases of Non - specific synovitis, later being diagnosed either as Osteoarthritis or Rheumatoid Arthritis. This is the greatest advantage in using this procedure.

  16. Repeatability in the assessment of multi-segment foot kinematics.

    Science.gov (United States)

    Deschamps, Kevin; Staes, Filip; Bruyninckx, Herman; Busschots, Ellen; Jaspers, Ellen; Atre, Ameya; Desloovere, Kaat

    2012-02-01

    A recently published systematic review on 3D multi-segment foot models has illustrated the lack of repeatability studies providing evidence for appropriate clinical decision making. The aim of the current study was to assess the repeatability of the recently published model developed by Leardini et al. [10]. Foot kinematics of six healthy adults were analyzed through a repeated-measures design including two therapists with different levels of experience and four test sessions. For the majority of the parameters moderate or good repeatability was observed for the within-day and between-day sessions. A trend towards consistently higher within- and between-day variability was observed for the junior compared to the senior clinician. The mean inter-session variability of the relative 3D rotations ranged between 0.9-4.2° and 1.6-5.0° for respectively the senior and junior clinician whereas for the absolute angles this variability increased to respectively 2.0-6.2° and 2.6-7.8°. Mean inter-therapist standard deviations ranged between 2.2° and 6.5° for the relative 3D rotations and between 2.8° and 7.6° for the absolute 3D rotations. The ratio of inter-therapist to inter-trial errors ranged between 1.8 and 5.5 for the relative 3D rotations and between 2.4 and 9.7 for the absolute 3D rotations. Absolute angle representation of the planar angles was found to be more difficult. Observations from the current study indicate that an adequate normative database can be installed in gait laboratories, however, it should be stressed that experience of therapists is important and gait laboratories should therefore be encouraged to put effort in training their clinicians.

  17. Modeling Rich Interactions in Session Search - Georgetown University at TREC 2014 Session Track

    Science.gov (United States)

    2014-11-01

    iterations triggered by query reformulations to accomplish a complex search task. In our groups’ 2013 work [1], we model this interactive process of session...algorithm is set as Language Modeling with Dirichlet smoothing. The smoothing parameter mu is set as 5000. In RL2, we adopt QCM algorithm [1] where we...hoc Retrieval Model (Ad-hoc) Our RL1 approach directly uses the current query of each session as search terms. The retrieval algorithm is Language

  18. Buffered Communication Analysis in Distributed Multiparty Sessions

    Science.gov (United States)

    Deniélou, Pierre-Malo; Yoshida, Nobuko

    Many communication-centred systems today rely on asynchronous messaging among distributed peers to make efficient use of parallel execution and resource access. With such asynchrony, the communication buffers can happen to grow inconsiderately over time. This paper proposes a static verification methodology based on multiparty session types which can efficiently compute the upper bounds on buffer sizes. Our analysis relies on a uniform causality audit of the entire collaboration pattern - an examination that is not always possible from each end-point type. We extend this method to design algorithms that allocate communication channels in order to optimise the memory requirements of session executions. From these analyses, we propose two refinements methods which respect buffer bounds: a global protocol refinement that automatically inserts confirmation messages to guarantee stipulated buffer sizes and a local protocol refinement to optimise asynchronous messaging without buffer overflow. Finally our work is applied to overcome a buffer overflow problem of the multi-buffering algorithm.

  19. Scenario Crisis Cases in Distance Learning Sessions

    Science.gov (United States)

    Antunes, A.

    2013-04-01

    We discuss early results using student-lead role-play of crises and disaster scenarios to encourage engagement in distance learning sessions. The disadvantage of distance learning via web interface—the lack of face-to-face and the ease with which a student can remain quiet—is balanced by the wealth of Internet-accessible media reports of past mission disasters. Capitol College minimizes the lecture component to simply frame each session's open-ended crisis in our Mission Operations engineering course. The students are presented with a historical ‘disaster’ but not its resolution; they present their course of action, then the lecturer steps in to debrief. With a wealth of past cases available on the web, use of scenarios rather than lectures shows early signs of being viable model for encouraging discussion and interaction within distance learning for a variety of course topics.

  20. Percutaneous biopsy of a metastatic common iliac lymph node using hydrodissection and a semi-automated biopsy gun

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Seong Yoon; Park, Byung Kwan [Dept. of Radiology, amsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2017-06-15

    Percutaneous biopsy is a less invasive technique for sampling the tissue than laparoscopic biopsy or exploratory laparotomy. However, it is difficult to perform biopsy of a deep-seated lesion because of the possibility of damage to the critical organs. Recently, we successfully performed CT-guided biopsy of a metastatic common iliac lymph node using hydrodissection and semi-automated biopsy devices. The purpose of this case report was to show how to perform hydrodissection and how to use a semi-automated gun for safe biopsy of a metastatic common iliac lymph node.

  1. Opening of the 123rd Council session

    CERN Multimedia

    Patrice Loïez

    2002-01-01

    The CERN Council held its 123rd session on 13 December 2002 under the chairmanship of Professor Maurice Bourquin. The election of the next Director General, the Baseline Plan for 2003-2010 and a new status for non-European states were among the items agreed. Photo 01: (left to right) Director-General Prof. Luciano Maiani, President of Council Prof. Maurice Bourquin, and Director of administration Jan van der Boon.

  2. Pragmalinguistic analysis of a psychotherapeutic session

    Directory of Open Access Journals (Sweden)

    Ricardo Alberto Andrade Rodríguez

    2010-07-01

    Full Text Available The present article is the preliminary result of the research titled: pragmalinguistic analysys of psychotherapeutic verbal interaction, realized in the context of the M.D. in linguistics in the Universitiy of Antioquia. It presents the pragmatic analysis of one psychotherapy session using the speech acts theory. As result, beside the contrast between that theory and the analyzed case, it can be found some consideration about the verbal interaction that happens in the individual psychotherapy.

  3. Overview of the TREC 2014 Session Track

    Science.gov (United States)

    2014-11-01

    present evaluation results and analysis. 2 Evaluation Tasks We use the word “session” to mean a sequence of reformulations along with any user interaction...query reformulations ). A single topic can have more than one session associated with it, since two different users could go about satisfying the same...collection consists of roughly 730 million English- language web pages, comprising approximately 5TB of compressed data. The dataset was crawled from the Web

  4. Physical Review X Q&A Session

    Science.gov (United States)

    2014-03-01

    Physical Review X (PRX) is already being recognized as a top-quality journal in physics. What are its current standards and strengths? How will it grow and evolve in the coming years? Why is PRX a journal for you? PRX editors and the Editorial Board invite you to a Q & A session, where we will answer these questions and others you have about the journal. Bring your questions and learn more about PRX. Light refreshments will be provided.

  5. Safety Training: scheduled sessions in April

    CERN Multimedia

    DGS Unit

    2011-01-01

    The following training courses are scheduled in April. You can find the full Safety Training programme on the Safety Training online catalogue. If you are interested in attending any of the below courses, please talk to your supervisor, then apply electronically via EDH from the course description pages, by clicking on SIGN-UP. Registration for all courses is always open – sessions for the less-requested courses are organized on a demand-basis only. Depending on the demand, a session will be organised later in the year. Biocell Training 26-APR-11 (08.30 – 10.00) in French 26-APR-11 (10.30 – 12.00) in French Conduite de plates-formes élévatrices mobiles de personnel (PEMP) 28-APR-11 to 29-APR-11 (08.00 – 17.30) in French* Sécurité chimique – Introduction 29-APR-11 (09.00 – 11.30) in French (*) session in French with the possibility of receiving the documentation in English   By Isabelle Cusato (H...

  6. Guidelines for processing and reporting of prostatic needle biopsies

    NARCIS (Netherlands)

    Th.H. van der Kwast (Theo); C. Lopes; C. Santonja; C.G. Pihl; I. Neetens; P. Martikainen (Pekka); S. di Lollo; L. Bubendorf; R.F. Hoedemaeker

    2003-01-01

    textabstractThe reported detection rate of prostate cancer, lesions suspicious for cancer, and prostatic intraepithelial neoplasia (PIN) in needle biopsies is highly variable. In part, technical factors, including the quality of the biopsies, the tissue processing, and histopatholo

  7. A position paper on standardizing the nonneoplastic kidney biopsy report

    NARCIS (Netherlands)

    A. Chang (Anthony); I.W. Gibson (Ian); A.H. Cohen (Arthur); J.J. Weening (Jan); J.C. Jennette (Charles); A.B. Fogo (Agnes)

    2012-01-01

    textabstractThe biopsy report for nonneoplastic kidney diseases represents a complex integration of clinical data with light, immunofluorescence, and electron microscopic findings. Practice guidelines for the handling and processing of the renal biopsy have previously been created. However, specific

  8. Factors that can minimize bleeding complications after renal biopsy.

    Science.gov (United States)

    Zhu, M S; Chen, J Z; Xu, A P

    2014-10-01

    Renal biopsy is a very important diagnostic tool in the evaluation of renal diseases. However, bleeding remains to be one of the most serious complications in this procedure. Many new techniques have been improved to make it safer. The risk factors and predictors of bleeding after percutaneous renal biopsy have been extensively reported in many literatures, and generally speaking, the common risk factors for renal biopsy complications focus on hypertension, high serum creatinine, bleeding diatheses, amyloidosis, advanced age, gender and so on. Our primary purpose of this review is to summarize current measures in recent years literature aiming at minimizing the bleeding complication after the renal biopsy, including the drug application before and after renal biopsy, operation details in percutaneous renal biopsies, nursing and close monitoring after the biopsy and other kinds of biopsy methods.

  9. A Prospective Randomized Trial of Two Different Prostate Biopsy Schemes

    Science.gov (United States)

    2016-07-03

    Prostate Cancer; Local Anesthesia; Prostate-Specific Antigen/Blood; Biopsy/Methods; Image-guided Biopsy/Methods; Prostatic Neoplasms/Diagnosis; Prostate/Pathology; Prospective Studies; Humans; Male; Ultrasonography, Interventional/Methods

  10. Diagnosis of prostate cancer with needle biopsy: Should all cases ...

    African Journals Online (AJOL)

    2011-06-11

    Jun 11, 2011 ... The sensitivity of PSA was 99.2%. ... Needle biopsy allows appropriate surgical treatment for patients whose .... 715 consecutive breast biopsies with at least two year follow‑up of benign lesions. ... The effects of castration.

  11. A randomised controlled trial comparing use of lignocaine periprostatic nerve block alone and combined with diclofenac suppository for patients undergoing transrectal ultrasound (TRUS)-guided prostate biopsy.

    Science.gov (United States)

    Ooi, Wei Ling; Hawks, Cynthia; Tan, Andrew H H; Hayne, Dickon

    2014-11-01

    To examine whether or not the combination of diclofenac suppository with peri-prostatic nerve block (PPNB) was effective in reducing the degree of pain experienced during transrectal ultrasound (TRUS)-guided prostate biopsy in a randomised single-blind placebo-controlled trial. In all, 96 patients having a planned TRUS-guided prostate biopsy were randomised into one of the following arms on a 1:1 basis: 10 mL 1% lignocaine PPNB and placebo suppository (control) or 10 mL 1% lignocaine PPNB and 100 mg diclofenac suppository (treatment). Pain scores were recorded using the Numerical Rating Scale for pain (0-10) at the following time-points: (i) introduction of probe, (ii) during biopsy, (iii) 1 h after biopsy, (iv) later that evening (≈6 h after biopsy) and (v) 1 day after biopsy. Patients were asked about their preferred method for pain control if a repeat TRUS-guided prostate biopsy was required: local anaesthetic (LA) again or intravenous sedation. There were no significant differences in age (P = 0.653) or PSA level (P = 0.584) between either study arm. The differences in pain scores between the control and treatment groups were not significant at Time 1 (probe insertion; P = 0.299), Time 2 (biopsy; P = 0.983), Time 4 (evening after; P = 0.231) and Time 5 (1 day after biopsy; P = 0.384). At Time 3 (1 h after biopsy), the control pain scale scores were statistically significantly higher than the treatment pain scale scores (P = 0.044). There was no difference between treatment (87%) and control (80%) groups as to whether they would prefer to repeat the biopsy under LA (P = 0.373). The use of a diclofenac suppository with PPNB did not show any clinically meaningful effect in decreasing pain or improving tolerability of TRUS-guided prostate biopsy and is not recommended. PPNB TRUS-guided biopsy is extremely well tolerated, with >80% of patients electing for subsequent LA biopsy if required. © 2014 The Authors. BJU International © 2014 BJU

  12. Skin biopsy in assessing meralgia paresthetica.

    Science.gov (United States)

    Wongmek, Arada; Shin, Susan; Zhou, Lan

    2016-04-01

    Meralgia paresthetica is a focal neuropathy caused by compression of the lateral femoral cutaneous nerve (LFCN). The disease can be difficult to assess by neurophysiological or imaging studies. We studied 5 patients who presented to our neuromuscular clinic from April 2012 to December 2014 with a clinical suspicion of meralgia paresthetica and had skin biopsies with intraepidermal nerve fiber density (IENFD) evaluation. The mean age at onset was 37.2 (range 21-59) years. There were 4 women and 1 man. Two were obese, 2 wore tight jeans, and 1 had mild diabetes mellitus. IENFD was reduced in the symptomatic proximal thigh in all 5 patients and was also reduced in the asymptomatic thigh in 2 patients. It was normal in the distal leg in 4 patients. Meralgia paresthetica is associated with loss of small intraepidermal nerve fibers. Skin biopsy with IENFD evaluation may be a useful diagnostic tool for this disease. © 2016 Wiley Periodicals, Inc.

  13. PATHOMORPHOLOGY OF ZERO BIOPSIES OF DONOR KIDNEYS

    Directory of Open Access Journals (Sweden)

    M. L. Arefjev

    2011-01-01

    Full Text Available There is well known fact that kidney transplants from Extended Criteria Donors may increase risk of De- layed Graft Function and Primary Non-Function of transplants. We have collected and tested 65 «zero» kidney biopsies from cadaver donors aged from 19 to 71 years old. In the pool of elderly donors who died from cerebrovascular accident the frequency of nephrosclerosis presentation was higher than in donors of yonger age who died from craniocephalic trauma. Nevertheless in the general donor pool the number of sclerosed glomeruli was no more than 12%. We did not meet at all in the whole volume of material any bi- opsy with the severe degree of arteriosclerosis. The «zero» biopsies of cadaver kidneys is quite usable and unexpensive tool to measure the degree of nephrosclerosis in order to exclude kidneys which are not fitable for transplantation. 

  14. Higher Prostate Cancer Grade Groups Are Detected in Patients Undergoing Multiparametric MRI-targeted Biopsy Compared With Standard Biopsy.

    Science.gov (United States)

    Gordetsky, Jennifer B; Thomas, John V; Nix, Jeffrey W; Rais-Bahrami, Soroush

    2017-01-01

    Recent studies have suggested that multiparametric magnetic resonance imaging (MRI)/ultrasound (US) fusion-guided prostate biopsy can detect more clinically significant prostate cancers, which could impact patient management. As many of the studies evaluating MRI/US fusion-guided prostate biopsy were conducted in specialized quaternary care centers, the question remains whether this technology is transferable to general practice. Our study assesses the diagnostic ability of MRI/US fusion-guided prostate biopsy compared with standard biopsy in the new era of prostate cancer Grade Grouping. We reviewed our prostate biopsy database evaluating men who underwent MRI/US fusion-guided prostate biopsy with concurrent standard 12-core extended-sextant biopsy. Patient demographics and pathologic findings were reviewed. All patient biopsies were performed by 1 of 2 urologic oncologists. Tumors were given a Grade Group for each biopsy based on the core with the highest grade in each case. A total of 191 patients underwent MRI/US fusion-guided biopsy with concurrent 12-core extended sextant biopsy, with a cancer detection rate of 56%. The average number of biopsy cores obtained via the targeted approach was significantly less than those obtained by standard biopsy, 4.8 cores versus 12 cores, respectively, Pbiopsy, 41.4% and 49.2%, respectively, P=0.15. However, when comparing the 2 techniques, the degree of detection of ≥Grade Group 3 tumors significantly favored targeted biopsy over standard biopsy (P=0.009). MRI/US fusion-guided prostate biopsy is equivalent to the standard-of-care 12-core biopsy in terms of cancer detection and superior in detecting higher grade disease.

  15. Expansion of protein domain repeats.

    Directory of Open Access Journals (Sweden)

    Asa K Björklund

    2006-08-01

    Full Text Available Many proteins, especially in eukaryotes, contain tandem repeats of several domains from the same family. These repeats have a variety of binding properties and are involved in protein-protein interactions as well as binding to other ligands such as DNA and RNA. The rapid expansion of protein domain repeats is assumed to have evolved through internal tandem duplications. However, the exact mechanisms behind these tandem duplications are not well-understood. Here, we have studied the evolution, function, protein structure, gene structure, and phylogenetic distribution of domain repeats. For this purpose we have assigned Pfam-A domain families to 24 proteomes with more sensitive domain assignments in the repeat regions. These assignments confirmed previous findings that eukaryotes, and in particular vertebrates, contain a much higher fraction of proteins with repeats compared with prokaryotes. The internal sequence similarity in each protein revealed that the domain repeats are often expanded through duplications of several domains at a time, while the duplication of one domain is less common. Many of the repeats appear to have been duplicated in the middle of the repeat region. This is in strong contrast to the evolution of other proteins that mainly works through additions of single domains at either terminus. Further, we found that some domain families show distinct duplication patterns, e.g., nebulin domains have mainly been expanded with a unit of seven domains at a time, while duplications of other domain families involve varying numbers of domains. Finally, no common mechanism for the expansion of all repeats could be detected. We found that the duplication patterns show no dependence on the size of the domains. Further, repeat expansion in some families can possibly be explained by shuffling of exons. However, exon shuffling could not have created all repeats.

  16. MR-guided transgluteal biopsies with an open low-field system in patients with clinically suspected prostate cancer: technique and preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Zangos, Stephan [Johann Wolfgang Goethe-University, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt/Main (Germany); Johann Wolfgang Goethe-University, Institute for Diagnostic and Interventional Radiology, Frankfurt/Main (Germany); Eichler, Katrin; Engelmann, Kerstin; Ahmed, Mukhtiar; Dettmer, Sebastian; Herzog, Christopher; Pegios, Wasilios; Wetter, A.; Lehnert, Thomas; Mack, Martin G.; Vogl, Thomas J. [Johann Wolfgang Goethe-University, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt/Main (Germany)

    2005-01-01

    The purpose of this study was to examine the feasibility and safety of MR-guided biopsies with a transgluteal approach in patients with uncertain or suspicious prostate lesions. Twenty-five patients with uncertain or suspicious focal prostate lesions detected by high-field MR imaging of the prostate gland using endorectal coil imaging were biopsied with a transgluteal approach in a low-field MRI system (0.2 T, Concerto, Siemens). The procedures were guided using T1-weighted FLASH sequences. The prostate gland was biopsied repeatedly with a coaxial technique through a 15-gauge pencil tip with a 16-gauge biopsy handy (median 3.8 samples per patient). Complications and biopsy findings were documented retrospectively. Using T1-weighted sequences biopsy procedures were performed successfully with MR guidance in all cases without any side effects or complications. The median intervention time was 11.3 min. Pathological findings revealed ten cases of hyperplasia or atrophy, three cases of prostatitis, ten cases of carcinoma and two cases of normal tissue. The clinical follow-up showed that in two patients prostate cancer was missed at MR-guided biopsy. Transgluteal MR-guided biopsy of the prostate gland is a safe and promising approach for histological clarification of uncertain or suspicious lesions. (orig.)

  17. [Is undirected liver biopsy a safe procedure?].

    Science.gov (United States)

    Oliva, L; Hirt, M

    1993-09-01

    In the authors' group of 976 umaimed liver biopsies (ULB) 10 complications were recorded. The authors described them and compared them with reports from the world literature. Two patients from the group died after ULB. One as a result of biopsy from haemoperitoneum, the other patient died with delirium tremens after surgery called for by persisting peritoneal syndrome. In eight patients mild complications were involved. In five patients complications receded spontaneously, in three after administration of an analgetic. From the submitted paper ensues that ULB is not quite safe, even when used by an experienced physician and when all contraindications are respected. A smooth course is not ensured by a risk-free diagnosis, previous uncomplicated biopsies normal prebioptic haemocoagulation tests. It is essential to realize this with regard to every patient where we indicate ULB. It is better to omit it unless we are unequivocally convinced of its asset. The question thus is: What will be the benefit of ULB for the patient?

  18. Repeatability and reproducibility of horizontal corneal diameter and anterior corneal power measurements using the Oculus Keratograph 4

    Directory of Open Access Journals (Sweden)

    Khathutshelo P. Mashige

    2016-03-01

    Full Text Available Purpose: To evaluate the repeatability and reproducibility of horizontal corneal diameter (HCD and anterior corneal power (ACP measurements obtained with the Oculus Keratograph 4 (OCULUS Optikgeräte GmbH.Methods: These parameters (HCD and ACP were prospectively measured in quick succession three times in each of the right eyes of 40 healthy subjects, aged 18–28 years, with normal vision (6/6 or better visual acuity in the first session by a single examiner. Measurements were then repeated in the second session scheduled 1 week later by the same examiner using the same instrument. Repeatability and reproducibility of HCD and ACP measurements was assessed based on the intra-session and intersession within-subject standard deviation (sw, repeatability (2.77sw, coefficient of variation (CoV and intra-class correlation coefficient (ICC.Results: Intra-session repeatability and intersession reproducibility of all measured parameters showed a repeatability (2.77sw of 0.35 mm or less for HCD and 0.35 D or less for ACP, a CoV of 0.30% or less and an ICC of more than 0.9.Conclusion: HCD and ACP measurements obtained using an Oculus Keratograph 4 show good repeatability and reproducibility in healthy eyes; therefore, these parameters can be used for longitudinal follow-up when measured with this device.

  19. Extrapleural paravertebral CT guided fine needle biopsy of subcarinal lymph nodes

    Energy Technology Data Exchange (ETDEWEB)

    Tantawy, Wahid H., E-mail: tantawyw@yahoo.com [Radiology Department, Faculty of Medicine, Ain Shams University, Egypt Abbassyia square, Cairo (Egypt); El-Gemeie, Emad H. [Pathology Department, National Cancer Institute, Fom El Khalige Faculty of Medicine, Cairo University (Egypt); Ibrahim, Ahmed S., E-mail: asibrahima@gmail.com [Radiology Department, Faculty of Medicine, Ain Shams University, Egypt Abbassyia square, Cairo (Egypt); Mohamed, Mona A. [Radiology Department, Faculty of Medicine, Ain Shams University, Egypt Abbassyia square, Cairo (Egypt)

    2012-10-15

    Purpose: To report our experience in CT guided extrapleural paravertebral subcarinal lymph biopsy using a thin 25 gauge (25 G) thin needle without the need of injection of saline to widen the mediastinum. Materials and methods: Biopsy was performed using a 25 G needle which was advanced lateral to the vertebral body between the endothoracic fascia and the parietal pleura to gain access to subcarinal lymph nodes. One hundred and forty one patients were included in the study (74 females, 57 males). No artificial widening of the mediastinum using saline injection was required. The study was performed in the presence of a cytopathologist; sensitivity and specificity rates were calculated. Complications were documented for each case especially for pneumothorax and haemorrhage. Results: Cytopathological diagnosis was reached in all cases. All re-aspirations were done in the same session to reach a primary diagnosis at the time of the biopsy. Imunophenotyping study was done in 94 cases to confirm the primary diagnosis and to classify the malignant lesions. No pneumothorax was encountered. Small haematomas were noted in 5 cases (3.5%). Cytopathology showed a sensitivity of 97.2% and specificity of 100%. By adding immunophenotyping a 100% sensitivity and specificity was achieved. Conclusion: Fine needle aspiration cytology (FNAC) using a 25 gauge needle for subcarinal lymph nodes via a percutaneous extrapleural paravertebral CT guided approach is a safe, minimally invasive, and tolerable procedure yielding a high sensitivity and specificity rates without the need of artificial widening.

  20. DWI Repeaters and Non-Repeaters: A Comparison.

    Science.gov (United States)

    Weeber, Stan

    1981-01-01

    Discussed how driving-while-intoxicated (DWI) repeaters differed signigicantly from nonrepeaters on 4 of 23 variables tested. Repeaters were more likely to have zero or two dependent children, attend church frequently, drink occasionally and have one or more arrests for public intoxication. (Author)

  1. To Repeat or Not to Repeat a Course

    Science.gov (United States)

    Armstrong, Michael J.; Biktimirov, Ernest N.

    2013-01-01

    The difficult transition from high school to university means that many students need to repeat (retake) 1 or more of their university courses. The authors examine the performance of students repeating first-year core courses in an undergraduate business program. They used data from university records for 116 students who took a total of 232…

  2. 21 CFR 870.4075 - Endomyocardial biopsy device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Endomyocardial biopsy device. 870.4075 Section 870...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Surgical Devices § 870.4075 Endomyocardial biopsy device. (a) Identification. An endomyocardial biopsy device is a device used in a catheterization...

  3. Tumor Seeding With Renal Cell Carcinoma After Renal Biopsy

    OpenAIRE

    M.F.B. Andersen; Norus, T.P.

    2016-01-01

    Tumor seeding following biopsy of renal cell carcinoma is extremely rare with an incidence of 1:10.000. In this paper two cases with multiple recurrent RRC metastasis in the biopsy tract following biopsy of renal tumor is presented and the current literature is shortly discussed.

  4. Studying different tasks of implicit learning across multiple test sessions conducted on the web

    Directory of Open Access Journals (Sweden)

    Werner eSævland

    2016-06-01

    Full Text Available Implicit learning is usually studied through individual performance on a single task, with the most common tasks being Serial Reaction Time task (SRT; Nissen and Bullemer, 1987, Dynamic System Control task (DSC; (Berry and Broadbent, 1984 and artificial Grammar Learning task (AGL; (Reber, 1967. Few attempts have been made to compare performance across different implicit learning tasks within the same experiment. The current experiment was designed study the relationship between performance on the DSC Sugar factory task (Berry and Broadbent, 1984 and the Alternating Serial Reaction Time task (ASRT; (Howard and Howard, 1997. We also addressed another limitation to traditional implicit learning experiments, namely that implicit learning is usually studied in laboratory settings over a restricted time span lasting for less than an hour (Berry and Broadbent, 1984; Nissen and Bullemer, 1987; Reber, 1967. In everyday situations, implicit learning is assumed to involve a gradual accumulation of knowledge across several learning episodes over a larger time span (Norman and Price, 2012. One way to increase the ecological validity of implicit learning experiments could be to present the learning material repeatedly across shorter experimental sessions (Howard and Howard, 1997; Cleeremans and McClelland, 1991. This can most easily be done by using a web-based setup that participants can access from home. We therefore created an online web-based system for measuring implicit learning that could be administered in either single or multiple sessions. Participants (n = 66 were assigned to either a single-session or a multi-session condition. Learning and the degree of conscious awareness of the learned regularities was compared across condition (single vs. multiple sessions and tasks (DSC vs. ASRT. Results showed that learning on the two tasks was not related. However, participants in the multiple sessions condition did show greater improvements in reaction

  5. Homeostatic plasticity in human motor cortex demonstrated by two consecutive sessions of paired associative stimulation.

    Science.gov (United States)

    Müller, J Florian M; Orekhov, Yuriy; Liu, Yali; Ziemann, Ulf

    2007-06-01

    Long-term potentiation (LTP) and long-term depression (LTD) underlie most models of learning and memory, but neural activity would grow or shrink in an uncontrolled manner, if not guarded by stabilizing mechanisms. The Bienenstock-Cooper-Munro (BCM) rule proposes a sliding threshold for LTP/LTD induction: LTP induction becomes more difficult if neural activity was high previously. Here we tested if this form of homeostatic plasticity applies to the human motor cortex (M1) in vivo by examining the interactions between two consecutive sessions of paired associative stimulation (PAS). PAS consisted of repeated pairs of electrical stimulation of the right median nerve followed by transcranial magnetic stimulation of the left M1. The first PAS session employed an interstimulus interval equalling the individual N20-latency of the median nerve somatosensory-evoked cortical potential plus 2 ms, N20-latency minus 5 ms, or a random alternation between these intervals, to induce an LTP-like increase in motor-evoked potential (MEP) amplitudes in the right abductor pollicis brevis muscle (PAS(LTP)), an LTD-like decrease (PAS(LTD)), or no change (PAS(Control)), respectively. The second PAS session 30 min later was always PAS(LTP). It induced an moderate LTP-like effect if conditioned by PAS(Control), which increased if conditioned by PAS(LTD), but decreased if conditioned by PAS(LTP). Effects on MEP amplitude induced by the second PAS session exhibited a negative linear correlation with those in the first PAS session. Because the two PAS sessions activate identical neuronal circuits, we conclude that 'homosynaptic-like' homeostatic mechanisms in accord with the BCM rule contribute to regulating plasticity in human M1.

  6. Time of day effects on repeated sprint ability.

    Science.gov (United States)

    Zarrouk, N; Chtourou, H; Rebai, H; Hammouda, O; Souissi, N; Dogui, M; Hug, F

    2012-12-01

    The present study aimed at investigating the effects of time-of-day on muscle power and associated electromyographic (EMG) activity level of 4 thigh muscles during a repeated pedalling sprint exercise. After a familiarization session, 12 male subjects were asked to perform the repeated sprint ability test during 2 experimental sessions (randomized order), which were set up either at 06:00 or 18:00 h. For each sprint, peak power output, percentage of peak power decrement and total work were calculated. EMG activity of vastus lateralis, rectus femoris, vastus medialis and biceps femoris muscles was recorded throughout the test and analyzed for each sprint. Total work and percentage of peak power decrement were higher in the evening than in the morning (psprints (psprint 1 and psprint 2 and 3). There was no time-of-day effect for EMG activity level. The neuromuscular efficiency decreased significantly over the repeated sprint ability test at the 2 times of testing (prepeated sprint ability test, EMG activity of major thigh muscles was not time-of-day dependent. © Georg Thieme Verlag KG Stuttgart · New York.

  7. Ultrasound-guided diagnostic breast biopsy methodology: retrospective comparison of the 8-gauge vacuum-assisted biopsy approach versus the spring-loaded 14-gauge core biopsy approach

    OpenAIRE

    Jimenez Rafael E; Povoski Stephen P; Wang Wenle P

    2011-01-01

    Abstract Background Ultrasound-guided diagnostic breast biopsy technology represents the current standard of care for the evaluation of indeterminate and suspicious lesions seen on diagnostic breast ultrasound. Yet, there remains much debate as to which particular method of ultrasound-guided diagnostic breast biopsy provides the most accurate and optimal diagnostic information. The aim of the current study was to compare and contrast the 8-gauge vacuum-assisted biopsy approach and the spring-...

  8. Nifty Nines and Repeating Decimals

    Science.gov (United States)

    Brown, Scott A.

    2016-01-01

    The traditional technique for converting repeating decimals to common fractions can be found in nearly every algebra textbook that has been published, as well as in many precalculus texts. However, students generally encounter repeating decimal numerals earlier than high school when they study rational numbers in prealgebra classes. Therefore, how…

  9. Nifty Nines and Repeating Decimals

    Science.gov (United States)

    Brown, Scott A.

    2016-01-01

    The traditional technique for converting repeating decimals to common fractions can be found in nearly every algebra textbook that has been published, as well as in many precalculus texts. However, students generally encounter repeating decimal numerals earlier than high school when they study rational numbers in prealgebra classes. Therefore, how…

  10. Repeated training with augmentative vibrotactile feedback increases object manipulation performance.

    Directory of Open Access Journals (Sweden)

    Cara E Stepp

    Full Text Available Most users of prosthetic hands must rely on visual feedback alone, which requires visual attention and cognitive resources. Providing haptic feedback of variables relevant to manipulation, such as contact force, may thus improve the usability of prosthetic hands for tasks of daily living. Vibrotactile stimulation was explored as a feedback modality in ten unimpaired participants across eight sessions in a two-week period. Participants used their right index finger to perform a virtual object manipulation task with both visual and augmentative vibrotactile feedback related to force. Through repeated training, participants were able to learn to use the vibrotactile feedback to significantly improve object manipulation. Removal of vibrotactile feedback in session 8 significantly reduced task performance. These results suggest that vibrotactile feedback paired with training may enhance the manipulation ability of prosthetic hand users without the need for more invasive strategies.

  11. Biopsy-proven spontaneous regression of a rhabdomyomatous mesenchymal hamartoma.

    Science.gov (United States)

    Mazza, Joni M; Linnell, Erica; Votava, Henry J; Wisoff, Jeffrey H; Silverberg, Nanette B

    2015-01-01

    Rhabdomyomatous mesenchymal hamartoma (RMH) is a rare, benign, congenital tumor of the dermis and subcutaneous tissue comprised of skeletal muscle and adipose and adnexal elements. Although the majority of cases are an incidental finding in otherwise healthy patients, some have been reported in association with other anomalies. We present a full-term boy evaluated on day 2 of life for two lesions located on the midline of the lower back and right buttock that each appeared clinically as an atrophic, pink plaque. Ultrasound of the midline lesion revealed an underlying lipomyelomeningocele with a tethered cord in the spinal canal. Histopathology of the right buttock cutaneous lesion was consistent with a diagnosis of RMH. Surgical excision was performed on the midline intradural lipoma and the lesion on the buttock was monitored clinically. Repeat biopsy of this site at 1 year of age revealed complete spontaneous regression. This case highlights three interesting features: the association with an occult spinal dysraphism lipomyelomeningocele and tethered cord, the clinical presentation of an atrophic plaque as opposed to the more commonly reported raised lesions, and the phenomenon of spontaneous regression of the lesion. Most importantly, this final feature of regression in our patient suggests that, in the absence of symptoms, clinical observation of RMH lesions is warranted for spontaneous regression for 1 to 2 years provided that no functional deficit is noted and that the cutaneous or deeper lesions are not causing a medical problem.

  12. Music Education and Music Therapy. Introduction to Plenary Session 3

    DEFF Research Database (Denmark)

    Bonde, Lars Ole

    2002-01-01

    Chairman's introduction to plenary session on the relationship between music therapy and music pedagogics......Chairman's introduction to plenary session on the relationship between music therapy and music pedagogics...

  13. 78 FR 53497 - Commercial Space Transportation Advisory Committee; Closed Session

    Science.gov (United States)

    2013-08-29

    ... Federal Aviation Administration Commercial Space Transportation Advisory Committee; Closed Session AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of Commercial Space Transportation Advisory... closed session of the Commercial Space Transportation Advisory Committee (COMSTAC). The special...

  14. Current concepts in the biopsy of musculoskeletal tumors.

    Science.gov (United States)

    Traina, Francesco; Errani, Costantino; Toscano, Angelo; Pungetti, Camilla; Fabbri, Daniele; Mazzotti, Antonio; Donati, Davide; Faldini, Cesare

    2015-01-07

    A musculoskeletal tumor biopsy can involve fine needle aspiration, core needle biopsy, or incisional biopsy. Controversy regarding the diagnostic yield of these biopsy techniques continues. The purpose of this article is to summarize the current concepts in the biopsy of musculoskeletal tumors. We performed a literature review of clinical articles reporting on the biopsy of bone and soft-tissue primary tumors. Clinical articles were excluded on the basis on abstract content if they represented case reports, review or opinion articles, or technique descriptions. Eighteen of the thirty-nine articles that remained were excluded because the results did not indicate the diagnostic accuracy of the various biopsy techniques. Thus, twenty-one articles with diagnostic data on the biopsy of bone and soft-tissue tumors were included in this review. Core needle biopsy appeared to be more accurate than fine needle aspiration, and incisional biopsy appeared to be more accurate than both of these techniques, but the differences did not reach significance. Incisional biopsy was more expensive than the percutaneous biopsy methods. In deep musculoskeletal tumors, incorporation of ultrasonography or computed tomography for guidance is easy and safe and can be useful for increasing the accuracy of the biopsy. Advantages of a percutaneous technique compared with an incisional one are the low risk of contamination and the minimally invasive nature. Certain anatomic locations and histologic types were associated with diagnostic difficulty. Vertebral tumors had the lowest diagnostic accuracy regardless of the biopsy technique. Myxoid, infection, and round cell histologies were associated with the lowest diagnostic accuracy. The current literature has not clarified the optimal biopsy technique for the diagnosis of bone and soft-tissue tumors. However, core needle biopsy is usually preferable to incisional biopsy because of the low risk of contamination and the low cost. In addition, the

  15. Image-guided breast biopsy: state-of-the-art

    Energy Technology Data Exchange (ETDEWEB)

    O' Flynn, E.A.M., E-mail: lizoflynn@doctors.org.u [South East London Breast Screening Programme and National Breast Screening Training Centre, Kings College Hospital NHS Foundation Trust, London SE5 9RS (United Kingdom); Wilson, A.R.M.; Michell, M.J. [South East London Breast Screening Programme and National Breast Screening Training Centre, Kings College Hospital NHS Foundation Trust, London SE5 9RS (United Kingdom)

    2010-04-15

    Percutaneous image-guided breast biopsy is widely practised to evaluate predominantly non-palpable breast lesions. There has been steady development in percutaneous biopsy techniques. Fine-needle aspiration cytology was the original method of sampling, followed in the early 1990s by large core needle biopsy. The accuracy of both has been improved by ultrasound and stereotactic guidance. Larger bore vacuum-assisted biopsy devices became available in the late 1990s and are now commonplace in most breast units. We review the different types of breast biopsy devices currently available together with various localization techniques used, focusing on their advantages, limitations and current controversial clinical management issues.

  16. All-photonic quantum repeaters

    Science.gov (United States)

    Azuma, Koji; Tamaki, Kiyoshi; Lo, Hoi-Kwong

    2015-01-01

    Quantum communication holds promise for unconditionally secure transmission of secret messages and faithful transfer of unknown quantum states. Photons appear to be the medium of choice for quantum communication. Owing to photon losses, robust quantum communication over long lossy channels requires quantum repeaters. It is widely believed that a necessary and highly demanding requirement for quantum repeaters is the existence of matter quantum memories. Here we show that such a requirement is, in fact, unnecessary by introducing the concept of all-photonic quantum repeaters based on flying qubits. In particular, we present a protocol based on photonic cluster-state machine guns and a loss-tolerant measurement equipped with local high-speed active feedforwards. We show that, with such all-photonic quantum repeaters, the communication efficiency scales polynomially with the channel distance. Our result paves a new route towards quantum repeaters with efficient single-photon sources rather than matter quantum memories. PMID:25873153

  17. Parallel Monitors for Self-adaptive Sessions

    Directory of Open Access Journals (Sweden)

    Mario Coppo

    2016-06-01

    Full Text Available The paper presents a data-driven model of self-adaptivity for multiparty sessions. System choreography is prescribed by a global type. Participants are incarnated by processes associated with monitors, which control their behaviour. Each participant can access and modify a set of global data, which are able to trigger adaptations in the presence of critical changes of values. The use of the parallel composition for building global types, monitors and processes enables a significant degree of flexibility: an adaptation step can dynamically reconfigure a set of participants only, without altering the remaining participants, even if the two groups communicate.

  18. The Safety of Multiple Flexible Sigmoidoscopies with Mucosal Biopsies in Healthy Clinical Trial Participants.

    Science.gov (United States)

    Chiu, Wai Kan; Brand, Rhonda M; Camp, Danielle; Edick, Stacey; Mitchell, Carol; Karas, Sherri; Zehmisch, Amanda; Ho, Ken; Brand, Randall E; Harrison, Janet; Abo, Steven; Cranston, Ross D; McGowan, Ian

    2017-08-01

    During Phase 1 pharmacokinetic/pharmacodynamics studies, participants may undergo multiple sigmoidoscopies, with a collection of 10-20 biopsies during each procedure. This article characterizes the safety of flexible sigmoidoscopies in clinical trial participants. We determined the number of flexible sigmoidoscopies and rectal biopsies that participants underwent and analyzed the frequency, duration, and severity of flexible sigmoidoscopy-related adverse events (AEs). During the study period, 278 participants underwent 1,004 flexible sigmoidoscopies with the collection of 15,930 rectal biopsies. The average number of procedures per participant was 3.6 (median 3; range 1-25), with an average time interval between procedures of 61.8 days (median 28 days; range 1-1,159). There were no serious AEs. Sixteen AEs were related to flexible sigmoidoscopy and occurred in 16 participants, leading to an overall 1.6% (16/1,004) AE rate per procedure and 0.1% (16/15,930) AE rate per biopsy. Of the 16 AEs, 8 (50%) involved abdominal pain, diarrhea, bleeding, flatulence, and bloating, with an average duration of 4.7 days (median 1 day; range 1-28). Most (14/16) AEs were categorized as Grade 1 (mild), whereas two of the AEs were Grade 2 (moderate). No participant withdrew due to procedure-related AEs. Overall, the number of AEs caused by flexible sigmoidoscopy with multiple biopsies was low and the severity was mild, suggesting that this procedure can be safely integrated into protocols requiring repeated intestinal mucosal sampling.

  19. Indications and results of renal biopsy in children: A single-center experience from Morocco

    Directory of Open Access Journals (Sweden)

    Fatima Zohra Souilmi

    2015-01-01

    Full Text Available The contribution of renal biopsy (RB is of major importance in the management of many renal diseases in children. Specific indications for performing biopsy in children include steroid-resistant nephrotic syndrome (NS and secondary nephropathies. The aim of our study was to report the common histological varieties of kidney diseases in children in Morocco. In this retrospective and descriptive study, we included all renal biopsies performed in patients under 16 years in the Department of Pediatrics of Hassan II University Hospital, Fez, Morocco from July 2009 to December 2013. Biopsy samples without glomeruli and those with less than five glomeruli or repeat biopsies on the same patient were excluded from our study. We performed 112 RBs during this period; the average age at the time of RB was 10.05 ± 4 years and the sex-ratio was 1.07. The indications for RB were NS with hematuria and/or renal failure (RF in 32.1%, active urinary sediment in 21.4%, isolated NS in 15.2%, RF in 13.4% and steroid-resistant NS in 10.7% of cases. Primary nephropathies represented 59.8% of cases, with a predominance of minimal change disease (MCD seen in 40.2% of the cases. Secondary nephropathies accounted for 27.7% of the cases, with a predominance of lupus nephritis (11.6%, followed by Henoch-Schonlein purpura nephritis (6.2% of cases and post-streptococcal glomerulonephritis (3.6%. There was one case of hepatitis B virus-associated membranous glomerulonephritis. Chronic glomerulonephritis accounted for 12.5% of the cases. Vascular and tubulo-interstitial nephritis were rare. Our study confirmed that primary glomerular nephropathy was the most common renal disease in children. The most common lesion was MCD. Secondary nephropathies were less frequent, with a predominance of lupus nephritis.

  20. Repeated cue exposure effects on subjective and physiological indices of chocolate craving

    NARCIS (Netherlands)

    van Gucht, D.; Vansteenwegen, D.; Beckers, T.; Hermans, D.; Baeyens, F.; Van den Bergh, O.

    2008-01-01

    The aim of this study is to investigate the effects of repeated unreinforced exposure to chocolate cues in persons reporting chocolate craving. Participants in the experimental group (n ¼ 40) received 10 consecutive brief exposures to chocolate cues in each of two sessions, separated by 1-3 days.

  1. Repeated cue exposure effects on subjective and physiological indices of chocolate craving

    NARCIS (Netherlands)

    van Gucht, D.; Vansteenwegen, D.; Beckers, T.; Hermans, D.; Baeyens, F.; Van den Bergh, O.

    2008-01-01

    The aim of this study is to investigate the effects of repeated unreinforced exposure to chocolate cues in persons reporting chocolate craving. Participants in the experimental group (n ¼ 40) received 10 consecutive brief exposures to chocolate cues in each of two sessions, separated by 1-3 days. Co

  2. Session Types for Access and Information Flow Control

    OpenAIRE

    Capecchi, Sara; Castellani, Ilaria; Dezani-Ciancaglini, Mariangiola; Rezk, Tamara

    2010-01-01

    We consider a calculus for multiparty sessions with delegation, enriched with security levels for session participants and data. We propose a type system that guarantees both session safety and a form of access control. Moreover, this type system ensures secure information flow, including controlled forms of declassification. In particular, it prevents leaks due to the specific control constructs of the calculus, such as session opening, selection, branching and delegation. We illustrate the ...

  3. Histomorphologic Features of Biopsy Sites Following Excisional and Core Needle Biopsies of the Breast.

    Science.gov (United States)

    Layfield, Lester J; Frazier, Shellaine; Schanzmeyer, Elizabeth

    2015-01-01

    Mammographic studies have documented a number of architectural changes occurring around breast biopsy sites. These changes are well described in the radiological literature, but similar studies do not appear to be present in the pathology literature. We reviewed 100 consecutive mastectomy specimens from women who had undergone prior core needle or excisional biopsies. Multiple sections of the needle tract or excisional biopsy site were reviewed and morphologic findings reported. Hemorrhage, fat necrosis, granulation tissue, necrosis of fibrous tissue, and epithelium along with fibrosis and foreign body type giant cells were common features. Less frequent were areas of synovial metaplasia, atypical spindle cells, atypical duct-like structures, single atypical cells, squamous metaplasia, proliferations of abnormal blood vessels, and hemosiderin deposition. The misinterpretation of atypical spindle cells, single atypical cells, atypical duct-like structures and squamous metaplasia could result in the false-positive diagnosis of residual malignancy. Careful attention to the reactive nature of these changes aids in their distinction from carcinoma.

  4. Accuracy of percutaneous lung biopsy for invasive pulmonary aspergillosis

    Energy Technology Data Exchange (ETDEWEB)

    Hoffer, F.A. [Dept. of Diagnostic Imaging, St. Jude Children' s Research Hospital, Memphis, TN (United States); Gow, K.; Davidoff, A. [Dept. of Surgery, St. Jude Children' s Research Hospital, Memphis, TN (United States); Flynn, P.M. [Dept. of Infectious Diseases, St. Jude Children' s Research Hospital, Memphis, TN (United States)

    2001-03-01

    Background. Invasive pulmonary aspergillosis is fulminant and often fatal in immunosuppressed patients. Percutaneous biopsy may select patients who could benefit from surgical resection. Objective. We sought to determine the accuracy of percutaneous biopsy for pediatric invasive pulmonary aspergillosis. Materials and methods. We retrospectively reviewed 28 imaging-guided percutaneous biopsies of the lungs of 24 children with suspected pulmonary aspergillosis. Twenty-two were being treated for malignancy and two for congenital immunodeficiency; 15 had received bone-marrow transplants. The accuracy of the percutaneous lung biopsy was determined by subsequent surgical resection, autopsy, or clinical course. Results. Histopathological studies showed ten biopsy specimens with septate hyphae, indicating a mold, and seven with Aspergillus flavus colonies in culture. The remaining 18 biopsies revealed no fungi. No patient had progressive aspergillosis after negative biopsy. Invasive pulmonary mold was detected by percutaneous biopsy with 100 % (10/10) sensitivity and 100 % (18/18) specificity. Percutaneous biopsy results influenced the surgical decision in 86 % (24 of 28) of the cases. Bleeding complicated the biopsy in 46 % (13/28) and hastened one death. Conclusion. Percutaneous biopsy of the lung is an accurate technique for the diagnosis of invasive pulmonary aspergillosis and correctly determines which immunosuppressed pediatric patients would benefit from therapeutic pulmonary resection. (orig.)

  5. Development of biopsy gun for aspiration and drug injection.

    Science.gov (United States)

    Kang, Hyun Guy; Cho, Sung Ho; Cho, Chang Nho; Kim, Kwang Gi

    2015-04-01

    Tumor samples are required for pathological examinations, and different instruments are generally used to obtain samples of different types of tumors. Among the many methods available for obtaining tumor tissues, gun biopsy is widely used because it is much simpler than incisional biopsy and can collect many more samples than aspiration biopsy. However, conventional biopsy guns cannot simultaneously perform biopsy aspiration, bleeding prevention, and marker injection. In this study, we developed a biopsy gun that can simultaneously perform biopsy aspiration and sample collection, in addition to injecting a styptic agent and marker to prevent bleeding and contamination in the biopsy track. We then used a prototype to evaluate the feasibility of the developed device. The collectable sample size was also assessed. Performance of the biopsy aspiration feature was also evaluated, including the maximum aspiration viscosity. Finally, we tested the maximum amount of drug that can be injected. We found that the biopsy gun developed here is an alternative tool for biopsy collection with improved procedure safety and diagnostic accuracy.

  6. Cumulative sessions of repetitive transcranial magnetic stimulation (rTMS) build up facilitation to subsequent TMS-mediated behavioural disruptions.

    Science.gov (United States)

    Valero-Cabré, Antoni; Pascual-Leone, Alvaro; Rushmore, Richard J

    2008-02-01

    A single session of repetitive transcranial magnetic stimulation (rTMS) can induce behavioural effects that outlast the duration of the stimulation train itself (off-line effects). Series of rTMS sessions on consecutive days are being used for therapeutic applications in a variety of disorders and are assumed to lead to the build-up of cumulative effects. However, no studies have carefully assessed this notion. In the present study we applied 30 daily sessions of 1 Hz rTMS (continuous train of 20 min) to repeatedly modulate activity in the posterior parietal cortex and associated neural systems in two intact cats. We assessed the effect on visuospatial orientation before and after each stimulation session. Cumulative sessions of rTMS progressively induced visuospatial neglect-like 'after-effects' of greater magnitude (from 5-10% to 40-50% error levels) and increasing spatial extent (from 90-75 degrees to 45-30 degrees eccentricity locations), affecting the visual hemifield contralateral to the stimulated hemisphere. Nonetheless, 60 min after each TMS session, visual detection-localization abilities repeatedly returned to baseline levels. Furthermore, no lasting behavioural effect could be demonstrated at any time across the study, when subjects were tested 1 or 24 h post-rTMS. We conclude that the past history of periodically cumulative rTMS sessions builds up a lasting 'memory', resulting in increased facilitation to subsequent TMS-induced disruptions. Such a phenomenon allows a behavioural effect of progressively higher magnitude, but equal duration, in response to individual TMS interventions.

  7. Within- and between-session reliability of power, force, and rate of force development during the power clean.

    Science.gov (United States)

    Comfort, Paul

    2013-05-01

    Although there has been extensive research regarding the power clean, its application to sports performance, and use as a measure of assessing changes in performance, no research has determined the reliability assessing the kinetics of the power clean across testing session. The aim of this study was to determine the within- and between-session reliability of kinetic variables during the power clean. Twelve professional rugby league players (age 24.5 ± 2.1 years; height 182.86 ± 6.97 cm; body mass 92.85 ± 5.67 kg; 1 repetition maximum [1RM] power clean 102.50 ± 10.35 kg) performed 3 sets of 3 repetitions of power cleans at 70% of their 1RM, while standing on a force plate, to determine within-session reliability and repeated on 3 separate occasions to determine reliability between sessions. Intraclass correlation coefficients revealed a high reliability within- (r ≥ 0.969) and between-sessions (r ≥ 0.988). Repeated-measures analysis of variance showed no significant difference (p > 0.05) in peak vertical ground reaction force, rate of force development, and peak power between sessions, with small standard error of the measurements and smallest detectable differences for each kinetic variable (3.13 and 8.68 N; 84.39 and 233.93 N·s; 24.54 and 68.01 W, respectively). Therefore, to identify a meaningful change in performance, the strength and conditioning coach should look for a change in peak force ≥8.68 N, rate of force development ≥24.54 N·s, and a change in peak power ≥68.01 W to signify an adaptive response to training, which is greater than the variance between sessions, in trained athletes proficient at performing the power clean.

  8. High-yield biopsy technique for subepidermal blisters.

    Science.gov (United States)

    Braswell, Mark A; McCowan, Nancye K; Schulmeier, Jennifer S; Brodell, Robert T

    2015-04-01

    Dermatologists often perform 2 biopsies in patients with widespread tense blisters: one for light microscopy and another for direct immunofluorescence (DIF). Biopsy techniques recommended for blistering diseases with tense blisters are discussed, and illustrations demonstrate an alternative approach utilizing a single punch biopsy. A single punch biopsy is more cost effective and provides the same diagnostic information as the standard 2-biopsy approach for subepidermal blisters plus additional salt-split skin-like diagnostic information. A limitation for bisecting the single punch biopsy specimen is a potential complete separation of the epidermis from the dermis. The single punch biopsy technique is a simple cost-effective method for obtaining necessary diagnostic information when sampling tense blisters in patients with blistering diseases.

  9. Mapping biopsy with punch biopsies to determine surgical margin in extramammary Paget's disease.

    Science.gov (United States)

    Kato, Takeshi; Fujimoto, Noriki; Fujii, Norikazu; Tanaka, Toshihiro

    2013-12-01

    It is difficult to determine the appropriate resection margin of extramammary Paget's disease (EMPD). A high recurrence rate is reported in spite of using Mohs micrographic surgery (MMS), which is performed commonly. Preoperative mapping biopsy is easier to perform than MMS. In Japan, the following method is recommended instead of MMS: well-defined border and margins histologically confirmed by mapping biopsy should be resected with 1-cm margin and ill-defined border with 3-cm margin. This study aimed to evaluate the accuracy of the Japanese guideline and to assess our mapping biopsy method compared with MMS. Preoperative mapping biopsy specimens were obtained beyond the clinical border for at least four directions in each patient. To confirm the presence of residual Paget's cells postoperatively, narrow specimens were obtained along the surgical margin. Retrospective evaluation of 17 EMPD patients was conducted concerning histological spread of Paget's cells and recurrence ratio. There were 86 directions showing a well-defined border, and in 9.3% (8/86), Paget's cells were still observed at 1-cm resection line. On the other hand, there were 21 directions showing an ill-defined border, and unnecessary radical resection was performed in 90% (19/21) of directions with 3-cm resection line. Although postoperative histological examination showed residual Paget's cells in 47% (8/17) of patients and additional resections were not performed, recurrence rate was only 5.9% (1/17). The resection line of EMPD should be based not on clinical features, but on mapping biopsy. Mapping biopsy is equivalent to MMS concerning recurrence rate and, though conventional, is useful method to treat EMPD.

  10. Graph Transformation for Consolidation of Creativity Sessions Results

    DEFF Research Database (Denmark)

    Dolog, Peter

    2010-01-01

    Graph transformation approach for consolidation of creativity sessions results is part of the FP7 EU/IST project idSpace: Tooling of and training for collaborative, distributed product innovation. The goal of graph transformation approach is to provide a tool for merging results of various sessio...... (such as brainstorming sessions), which are represented as graphs, when the session participants- are physically distributed....

  11. The biopsy of the boar testes using ultrasonographic examination

    Directory of Open Access Journals (Sweden)

    Laima Liepa

    2014-03-01

    Full Text Available The biopsy of live animal testes is an important clinical manipulation to control spermatogenesis and reproductive system pathologies. The aim was to develop a method of boar testes biopsy using a biopsy gun with ultrasound guidance and to investigate the influence of this procedure on the boar testes parenchyma and quality of ejaculate. The biopsy was carried out in six 8-month-old boars. Fourteen days prior to and 21 days after biopsy, the quality of ejaculate was examined (weight of ejaculate; concentration and motility of spermatozoa with a seven-day intervals. Ultrasound images of the testes parenchyma were recorded three times: directly before and 15 minutes after the biopsy, then 21 days after the procedure. The testes biopsies of generally anesthetized boars were performed with the biopsy gun for needle biopsy with a 12cm long, disposable 16-gauge needle 1.8mm in diameter (Vitesse through 1cm skin incision in the depth of 1.2-1.6cm of parenchyma. Fifteen minutes after the biopsy, macroscopic injures of the parenchyma of all the boar testes were not detected in the ultrasound image. Twenty one days after biopsy, the hyperechogenic line 0.1-0.2cm in diameter was seen in the testes parenchyma of six boars in the depth of 1.2-1.6cm. The biopsy of boar testes did not influence the quality of boars ejaculate. The ultrasonographic examination of boar testicles before the biopsy reduced possibilities to traumatize large blood vessels of the testes. A perfect boar testicular biopsy was easy to perform using ultrasonographic examination in the pigsty conditions.

  12. Safety Training: scheduled sessions in March

    CERN Multimedia

    DGS Unit

    2011-01-01

    The following training courses are scheduled in March. You can find the full Safety Training programme on the Safety Training online catalogue. If you are interested in attending any of the below courses, please talk to your supervisor, then apply electronically via EDH from the course description pages, by clicking on SIGN-UP. Registration for all courses is always open – sessions for the less-requested courses are organized on a demand-basis only. Depending on the demand, a session will be organised later in the year. Biocell Training 08-MAR-11 (08.30 – 10.00) in English 08-MAR-11 (10.30 – 12.00) in French 15-MAR-11 (08.30 – 10.00) in French 15-MAR-11 (10.30 – 12.00) in French 17-MAR-11 (08.30 – 10.00) in English 17-MAR-11 (10.30 – 12.00) in English 22-MAR-11 (08.30 – 10.00) in French 22-MAR-11 (10.30 – 12.00) in French 24-MAR-11 (08.30 – 10.00) in French 24-MAR-11 (10.30 – 12.00) in French 29-MAR...

  13. Aspen Global Change Institute Summer Science Sessions

    Energy Technology Data Exchange (ETDEWEB)

    Katzenberger, John; Kaye, Jack A

    2006-10-01

    The Aspen Global Change Institute (AGCI) successfully organized and convened six interdisciplinary meetings over the course of award NNG04GA21G. The topics of the meetings were consistent with a range of issues, goals and objectives as described within the NASA Earth Science Enterprise Strategic Plan and more broadly by the US Global Change Research Program/Our Changing Planet, the more recent Climate Change Program Strategic Plan and the NSF Pathways report. The meetings were chaired by two or more leaders from within the disciplinary focus of each session. 222 scholars for a total of 1097 participants-days were convened under the auspices of this award. The overall goal of each AGCI session is to further the understanding of Earth system science and global environmental change through interdisciplinary dialog. The format and structure of the meetings allows for presentation by each participant, in-depth discussion by the whole group, and smaller working group and synthesis activities. The size of the group is important in terms of the group dynamics and interaction, and the ability for each participant's work to be adequately presented and discussed within the duration of the meeting, while still allowing time for synthesis

  14. Safety Training: scheduled sessions in May

    CERN Multimedia

    Isabelle Cusato (HSE Unit)

    2011-01-01

    The following training courses are scheduled in March. You can find the full Safety Training programme on the Safety Training online catalogue. If you are interested in attending any of the below courses, please talk to your supervisor, then apply electronically via EDH from the course description pages, by clicking on SIGN-UP. Registration for all courses is always open – sessions for the less-requested courses are organized on a demand-basis only. Depending on the demand, a session will be organised later in the year.   Biocell Training 10-MAY-11 (08.30 – 10.00) in French 10-MAY-11 (10.30 – 12.00) in French 12-MAY-11 (08.30 – 10.00) in English 12-MAY-11 (10.30 – 12.00) in English 19-MAY-11 (08.30 – 10.00) in French 19-MAY-11 (10.30 – 12.00) in French 24-MAY-11 (08.30 – 10.00) in English 24-MAY-11 (10.30 – 12.00) in English   Champs Magnétiques 13-MAY-11 (09.30 – 11.30) in French...

  15. Towards the mid-infrared optical biopsy

    DEFF Research Database (Denmark)

    Seddon, Angela B.; Benson, Trevor M.; Sujecki, Slawomir

    2016-01-01

    We are establishing a new paradigm in mid-infrared molecular sensing, mapping and imaging to open up the mid-infrared spectral region for in vivo (i.e. in person) medical diagnostics and surgery. Thus, we are working towards the mid-infrared optical biopsy ('opsy' look at, bio the biology) in situ...... of a bright mid-infrared wideband source in a portable package as a first step for medical fiber-based systems operating in the mid-infrared. Moreover, mid-infrared molecular mapping and imaging is potentially a disruptive technology to give improved monitoring of the environment, energy efficiency, security...

  16. Transvitreal retino-choroidal biopsy of suspected malignant lesions of the choroid

    DEFF Research Database (Denmark)

    Jensen, O.A.; Prause, J.U.; Scherfig, E.

    1997-01-01

    ophthalmology, intraocular biopsy, transvitreal retino-choroidal biopsy, malignant melanoma of choroid, histopathology, brachytherapy......ophthalmology, intraocular biopsy, transvitreal retino-choroidal biopsy, malignant melanoma of choroid, histopathology, brachytherapy...

  17. Kinetics of Hepatitis B Virus Load During Haemodialysis Sessions and α-Interferon: A Prospective Study

    Directory of Open Access Journals (Sweden)

    Fabrizio Fabrizi

    2013-09-01

    Full Text Available Background: It has been reported a slow progression of hepatitis B in patients undergoing maintenance dialysis, and a role of dialysis session per se has been suggested. The aim of the present study is to evaluate the kinetics of the hepatitis B viral load (HBV DNA in serum during haemodialysis sessions using a highly sensitive technique; the role of interferon-α in lowering HBV viral load in such patients was also investigated. Methods: HBV DNA was determined in 24 HBsAg positive patients on maintenance hemodialysis immediately before and after a 4-hour hemodialysis session, the same measurements were repeated 48 and 72 hours later. HBV DNA quantitation was performed by a novel RealTime PCR assay. Serum IFN-α levels were tested in parallel in a subset of HD sessions (n=40 by ELISA. Results: 20 (83% HBsAg positive patients had detectable HBV DNA in serum. Positive status for HBV DNA in serum was not predicted by demographic, clinical or biochemical parameters. HBV load decreased in many patients after hemodialysis sessions 5.92 log10 IU/mL (95% CI, 5.34 to 6.28 log10 IU/mL vs. 4.79 log10 IU/mL (95% CI, 4.23 to 6.15 log10 IU/mL (P=0.02. A significant relationship between mean HBV DNA levels before dialysis and percentage reduction of HBV DNA during HD sessions occurred [F-test=5.41, rho (least squares=0.307]. Increase of serum IFN-α levels was found in a minority (3/40=7% of HD sessions. Conclusions: Hemodialysis procedure gives reduction of HBV load in HBsAg chronic carriers; no relationship with IFN-α activity during HD sessions was found. The kinetics of HBV viremia in HD procedures could explain the low viral load which is typically observed in these patients. Further studies to identify the mechanisms responsible for reduction of HBV viremia during HD procedures are under way.

  18. Sedation as an alternative method to lessen patient discomfort due to transrectal ultrasonography-guided prostate biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Turgut, A.T. [Department of Radiology, Ankara Training and Research Hospital, Ministry of Health, TR-06590 Ankara (Turkey)]. E-mail: ahmettuncayturgut@yahoo.com; Ergun, E. [Department of Radiology, Ankara Training and Research Hospital, Ministry of Health, TR-06590 Ankara (Turkey); Kosar, U. [Department of Radiology, Ankara Training and Research Hospital, Ministry of Health, TR-06590 Ankara (Turkey); Kosar, P. [Department of Radiology, Ankara Training and Research Hospital, Ministry of Health, TR-06590 Ankara (Turkey); Ozcan, A. [Department of Anesthesiology and Reanimation, Ankara Training and Research Hospital, Ministry of Health, TR-06590 Ankara (Turkey)

    2006-01-15

    Background: Despite being highly efficient for the relief of patient discomfort due to transrectal ultrasound (TRUS) guided prostate biopsy, periprostatic anesthesia is occasionally reported to be of limited use. We aimed to evaluate the efficacy of conscious sedation, an accepted method for lessening patient discomfort due to interventional radiological procedures and compare it with periprostatic anesthesia. Methods: 93 candidates for biopsy were randomised to three groups: group 1 (n = 31) received intravenous midazolam, group 2 (n = 31) received periprostatic lidocaine injection, whereas group 3 (n = 31) received no anesthetic before the procedure. After the biopsy patients were asked to express discomfort by visual anologue scale (VAS). Results: The mean scores for groups 1 and 2 were significantly lower than that of group 3 (1.4 {+-} 1.1 and 2.0 {+-} 1.5 versus 4.7 {+-} 1.6, respectively; p < 0.05 for both). For patients with VAS scores exceeding 4 (moderate to severe discomfort), a significant difference was calculated between groups 1 and 2 (3% versus 29%, p < 0.05) and between each and group 3 (3% and 29% versus 80%, respectively; p < 0.05 for each). Conclusions: Sedation is an alternative for increasing patient comfort during TRUS-guided prostate biopsy, especially in clinical situations like patient anxiety, young age, repeat biopsies or inflammatory anal diseases.

  19. Visual loss and presumed pseudoxanthoma elasticum confirmed with genetic analysis but not with skin examination and biopsies

    Directory of Open Access Journals (Sweden)

    Aerts, Carolien

    2011-01-01

    Full Text Available Objective: Case report of a patient with angioid streaks, peau d’orange, comet tail lesions, choroidal neovascularisation and presumed pseudoxanthoma elasticum (PXE. PXE was confirmed by gene analysis but not by skin biopsies. Methods: Case report of a patient with angioid streaks identified at age 21 and follow-up till age 43 with repeated fluorescein angiography (FA and optical coherence tomography (OCT. Dermatologic examination, skin biopsies and genetical analysis performed to confirm suspected diagnosis of PXE. Results: At age 43, no specific skin lesions were identified and 3 biopsies could not confirm PXE. Genetic analysis showed a homozygous mutation in the ABCC6 gene and confirmed the diagnosis of PXE. Conclusions: This case illustrates that in patients with angioid streaks having strong ocular indicators of PXE, confirmation of PXE can be obtained not only with dermatologic examination and skin biopsies, but also with genetic analysis. PXE associated mutations can be detected occasionally in biopsy negative patients and for this reason are extremely helpful in confirming a suspected diagnosis.

  20. Core needle biopsies and surgical excision biopsies in the diagnosis of lymphoma-experience at the Lymph Node Registry Kiel.

    Science.gov (United States)

    Johl, Alice; Lengfelder, Eva; Hiddemann, Wolfgang; Klapper, Wolfram

    2016-08-01

    Current guidelines of the European Society of Medical Oncology recommend surgical excision biopsies of lymph nodes for the diagnosis of lymphoma whenever possible. However, core needle biopsies are increasingly used. We aimed to understand the common practice to choose the method of biopsy in Germany. Furthermore, we wanted to understand performance of surgical excision and core needle biopsies of lymph nodes in the diagnosis of lymphoma. The files of 1510 unselected, consecutive lymph node specimens from a consultation center for lymphoma diagnosis were analyzed. Core needle biopsies were obtained frequently from lymph nodes localized in mediastinal, abdominal, retroperitoneal, or thoracic regions. Patients undergoing core needle biopsies were significantly older and suffered significantly more often from lymphoma than patients undergoing surgical excision biopsies. Although more immunohistochemical tests were ordered by the pathologist for core needle biopsies specimens than for surgical excision biopsies specimens, core needle biopsies did not yield a definite diagnosis in 8.3 % of cases, compared to 2.8 % for SEB (p = 0.0003). Restricting the analysis to cases with a final diagnosis of follicular lymphoma or diffuse large B-cell lymphoma, core needle biopsies identified a simultaneous low- and high-grade lymphoma (transformation) in 3.3 % of cases, compared to 7.6 % for surgical excision biopsies (p = 0.2317). In Germany, core needle biopsies are preferentially used in elderly patients with a high likelihood of suffering from lymphoma. Core needle appeared inferior to surgical excision biopsies at providing a definite diagnosis and at identifying multiple lymphoma differentiations and transformation.

  1. Serial prostate biopsy and risk of lower urinary tract symptoms: results from a large, single-institution active surveillance cohort.

    Science.gov (United States)

    Glass, Allison S; Hilton, Joan F; Cowan, Janet E; Washington, Samuel L; Carroll, Peter R

    2014-01-01

    To describe the effect of serial prostate biopsy on lower urinary tract symptoms (LUTS) in men who undergo active surveillance (AS) at a large academic institution. This is a retrospective study of men enrolled in AS for ≥6 months who underwent ≥1 biopsy and completed ≥1 International Prostate Symptom Score (IPSS) questionnaire. In additional to total IPSS, we report the mean difference between the first and last questionnaires for patients who completed ≥2 questionnaires. Multivariate models, adjusting for disease features, age, race, prostate volume and baseline, or incident benign prostatic hypertrophy (BPH), were used to assess relationships between IPSS and total biopsy exposure. Four hundred eighty-two men were eligible, and 291 completed ≥2 IPSS questionnaires. Overall, mean (standard deviation) age was 61.7 (7.8) years, and median prostate volume (interquartile range) was 42 (34-61) mL. At baseline, 11% provided history of BPH. Among men who completed multiple questionnaires, 25% experienced clinically significant worsening (IPSS increase ≥4 points). In regression model, total IPSS was not significantly associated with greater biopsy exposure (P = .25). IPSS change from initial and the latest questionnaire was not significantly associated with initial or interval biopsy exposure in an adjusted longitudinal model (P = .64 and .50, respectively), but a trend was observed with greater age decade (+4.07 points, 95% CI -0.30 to 8.4; P = .07). Repeated prostate biopsy does not appear to independently pose additional risk of LUTS in an AS population. In unadjusted analyses, greater biopsy exposure is a surrogate for increasing follow-up time, age, and BPH risk, and thus, risk of LUTS onset and progression. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Initial CT-guided needle biopsy of extremity skeletal lesions: Diagnostic performance and experience of a tertiary musculoskeletal center

    Energy Technology Data Exchange (ETDEWEB)

    Nouh, Mohamed Ragab, E-mail: mragab73@yahoo.com [Department of Radiology, Faculty of Medicine, Alexandria University (Egypt); Department of Radiology, Al-Razi Hospital, Sulibikhate 13001 (Kuwait); Abu Shady, Hamdy Mohamed, E-mail: hamdi_abushadi@yahoo.com [Department of Radiology, Al-Razi Hospital, Sulibikhate 13001 (Kuwait)

    2014-02-15

    Introduction: Appendicular long bones are the target for a wide spectrum of bony lesions with variable clinical presentations. Biopsy procedures are needed for subsequent proper patient's management. Most of the available literature globally assessed musculoskeletal biopsies with inclusion of repeat biopsy results. We thought to retrospectively assess the diagnostic performance of initial CT-guided percutaneous core needle biopsy (PCNB) of extremity long bone lesions in a tertiary musculoskeletal referral center. Patients and methods: We retrospectively analyzed the outcome of initial CT-guided PCNB of 49 patients who presented with extremity long bone lesions which were biopsied in our hospital during a 36 months’ time period. The diagnostic performance was assessed in terms of diagnostic yield and accuracy. Results: There were 34 males and 15 females with a mean age of 33.69 years (range from 4 to 77 years). The overall diagnostic yield of initial biopsies was 87.75% with a diagnostic accuracy of 82.85% derived from the surgically proven cases. The higher diagnostic yield was recorded with malignancy, presence of extra-osseous soft-tissue component as well as mixed and sclerotic lesions. The pathologies of the non-diagnostic biopsies included large-cell lymphoma, giant-cell tumor, langerhans cell histiocytosis, osteoid osteoma and a non-ossifying fibroma. Conclusion: Initial CT-guided PCNB in extremities’ long bones lesions showed high diagnostic performance in malignant, mixed and/or sclerotic lesions as well as lesions with extra-osseous exophytic tissue growth. Lack of extra-osseous components, benign and lytic lesions all had worse diagnostic performance.

  3. Dengue: muscle biopsy findings in 15 patients

    Directory of Open Access Journals (Sweden)

    S.M.F. Malheiros

    1993-06-01

    Full Text Available Dengue is known to produce a syndrome involving muscles, tendons and joints. The hallmark of this syndrome is severe myalgia but includes fever, cutaneous rash, and headache. The neuromuscular aspects of this infection are outlined only in isolated reports, and the muscle histopathological features during myalgia have not been described. In order to ascertain the actual neuromuscular involvement in dengue and better comprehend the histological nature of myalgia, we performed a clinical and neurological evaluation, a serum CPK level and a muscle biopsy (with histochemistry in 15 patients (4 males, median age 23 years (range 14-47 with classic dengue fever, serologically confirmed, during the bra-zilian dengue epidemics from September 1986 to March 1987. All patients had a history of fever, headache and severe myalgia. Upon examination 4 had a cutaneous rash, 3 had fever, and 3 a small hepatomegaly. The neurological examination was unremarkable in all and included a manual muscle test. CPK was mildly elevated in only 3 patients. Muscle biopsy revealed a light to moderate perivascular mononuclear infiltrate in 12 patients and lipid accumulation in 11. Mild mitochondrial proliferation was seen in 3, few central nuclei in 3, rare foci of myonecrosis in 3, and 2 patients had type grouping. Dengue in our patients, produced myalgia but no detectable muscle weakness or other neuromuscular involvement. The main histopathological correlation with myalgia seems to be a perivascular mononuclear infiltrate and lipid accumulation.

  4. [Diabetic foot microbiology through biopsy cultures].

    Science.gov (United States)

    Cabeza-De-Vaca, Francisco; Macías, Alejandro Ernesto; Alvarez, José Antonio; Cuevas, Aurora; Ramirez, América Jazmín; Ramírez, Welsy Araceli; Sifuentes-Osornio, José

    2009-01-01

    To determine the microbiology of diabetic foot wounds, through biopsy cultures. Patients with diabetic foot and clinical data of infection were recruited consecutively. Cultures were processed for aerobic organisms after mortar homogenization. For cases with multiple isolates, only the two predominant organisms were identified. The bacterial identification was carried out by biochemical procedures. The sensitivity to antibiotics was made by the disk diffusion method. A total of 91 biopsies were studied, 47 from men (52%). There were 102 isolates, 68 being Gram-negative bacilli (67%), with predominance of Escherichia coli (21%). A total of 28 Gram-positive cocci were isolated (28%) and 6 yeasts (6%). Of the 68 Gram-negative bacilli, 24 were resistant to ciprofloxacin (35%). A total of 55 Enterobacteriaceae were isolated, of which 4 (7%) produced extended-spectrum beta-lactamases. There were 8 Staphylococcus aureus isolates, 3 of which (38%) were resistant to methicillin. In comparison with reports from industrialized countries, we found a higher proportion of Gram-negative and resistant organisms.

  5. Liquid biopsies: tumor diagnosis and treatment monitoring

    Directory of Open Access Journals (Sweden)

    Binh Thanh Vu

    2016-08-01

    Full Text Available Cancer is a disease with high evolutionary, i.e., malignant, characteristics that change under selective pressure from therapy. Characterization based on molecular or primary tumor properties or clinicopathological staging does not fully reflect the state of cancer, especially when cancer cells metastasize. This is the major reason for failure of cancer treatment. Currently, there is an urgent need for new approaches that allow more effective, but less invasive, monitoring of cancer status, thereby improving the efficacy of treatments. With recent technological advances, and ldquo;liquid biopsies, and rdquo; the isolation of intact cells or analysis of components that are secreted from cells, such as nucleic acids or exosomes, could be implemented easily. This approach would facilitate real-time monitoring and accurate measurement of critical biomarkers. In this review, we summarize the recent progress in the identification of circulating tumor cells using new high-resolution approaches and discuss new circulating tumor nucleic acid- and exosome-based approaches. The information obtained through liquid biopsies could be used to gain a better understanding of cancer cell invasiveness and metastatic competence, which would then benefit translational applications such as personalized medicine. [Biomed Res Ther 2016; 3(8.000: 745-756

  6. Working through: In-Session Processes that Promote Between-Session Thoughts and Activities

    Science.gov (United States)

    Owen, Jesse; Quirk, Kelley; Hilsenroth, Mark J.; Rodolfa, Emil

    2012-01-01

    This study examined whether clients' ratings of the working alliance as well as their perception of cognitive-behavioral (CB) and psychodynamic-interpersonal (PI) techniques (delivered by therapists who used both) were associated with clients' intersession processes (i.e., their thoughts about therapy and therapeutic activity between sessions).…

  7. Basics of kidney biopsy: A nephrologist′s perspective

    Directory of Open Access Journals (Sweden)

    S K Agarwal

    2013-01-01

    Full Text Available The introduction of the kidney biopsy is one of the major events in the history of nephrology. Primary indications of kidney biopsy are glomerular hematuria/proteinuria with or without renal dysfunction and unexplained renal failure. Kidney biopsy is usually performed in prone position but in certain situations, supine and lateral positions may be required. Biopsy needles have changed with times from Vim-Silverman needle to Tru-cut needle to spring-loaded automatic gun. The procedure has also changed from blind bedside kidney biopsy to ultrasound marking to real-time ultrasound guidance to rarely computerized tomography guidance and laparoscopic and open biopsy. In very specific situations, transjugular kidney biopsy may be required. Most of the centers do kidney biopsy on short 1-day admission, whereas some take it as an outdoor procedure. For critical interpretation of kidney biopsy, adequate sample and clinical information are mandatory. Tissue needs to be stained with multiple stains for delineation of various components of kidney tissue. Many consider that electron microscopy (EM is a must for all kidney biopsies, but facilities for EM are limited even in big centers. Sophisticated tests such as immunohistochemistry and in-situ hybridization are useful adjuncts for definitive diagnosis in certain situations.

  8. Magnetic Resonance Imaging Guided Vacuum Assisted and Core Needle Biopsies.

    Science.gov (United States)

    Kılıç, Fahrettin; Eren, Abdulkadir; Tunç, Necmettin; Velidedeoğlu, Mehmet; Bakan, Selim; Aydoğan, Fatih; Çelik, Varol; Gazioğlu, Ertuğrul; Yılmaz, Mehmet Halit

    2016-01-01

    The purpose of this study to present the results of Magnetic resonance imaging (MRI) guided cutting needle biopsy procedures of suspicious breast lesions that can be solely detected on Magnetic resonance (MR) examination. The study included 48 patients with 48 lesions which were solely be observed in breast MRI, indistinguishable in ultrasonography and mammography, for MR guided vacuum-assisted cutting needle biopsy and 42 patients with 42 lesions for MR guided cutting needle biopsy for the lesions of the same nature. MR imaging was performed using a 1.5-Tesla MRI device. Acquired MR images were determined and biopsy protocol was performed using computer-aided diagnosis system on the workstation. Vacuum biopsies were performed using 10 G or 12 G automatic biopsy systems, cutting needle biopsy procedures were performed using fully automated 12 G biopsy needle. All biopsy procedures were finalized successfully without major complications. The lesions were 54 mass (60%), 28 were non-mass contrast enhancement (31%) and 8 were foci (9%) in the MR examination. Histopathological evaluation revealed 18 malignant (invasive, in-situ ductal carcinoma and lobular carcinoma), 66 benign (apocrine metaplasia, fibrosis, fibroadenomatoid lesion, sclerosing adenosis, fibrocystic disease and mild-to-severe epithelial proliferation) and 6 high-risk (atypical ductal hyperplasia, intraductal papilloma, radial scar) lesions. Magnetic resonance guided vacuum and cutting needle biopsy methods are successful methods fort he evaluation of solely MRI detected suspicious breast lesions. There are several advantages relative to each other in both methods.

  9. Diagnostic quality of biopsy specimens: comparison between a conventional biopsy forceps and multibite forceps.

    Science.gov (United States)

    Fantin, A C; Neuweiler, J; Binek, J S; Suter, W R; Meyenberger, C

    2001-11-01

    The endoscopic biopsy is a prerequisite for histopathologic diagnosis. Various types of forceps are used to obtain tissue specimens. The aim of this study was to assess and compare the diagnostic quality of biopsy specimens obtained with a conventional forceps and a Multibite forceps. In a prospective, partially blinded, and randomized trial that included 250 patients referred for diagnostic upper and/or lower endoscopy, 510 biopsy specimens obtained with the Multibite forceps were compared with 520 specimens obtained with a conventional forceps. An experienced, blinded pathologist evaluated the specimens for diameter, depth of specimen, artifacts, anatomic orientation, vitality, general histologic quality, and diagnostic quality. Statistical analysis was performed by using the Fisher exact test. A p value of < 0.05 was regarded as significant. There were no statistically significant differences between the specimens obtained with the 2 forceps. The p values for the evaluated parameters were as follows: diameter 0.45, depth of specimen 0.56, artifacts 1.0, pathoanatomic orientation 0.40, vitality 0.45, and histologic diagnostic quality 0.53. The quality of biopsy specimens obtained with the Multibite forceps is comparable with that of specimens taken with a conventional forceps. Use of the Multibite forceps saves time in that 4 specimens can be obtained in 1 pass in situations in which a large number of specimens are needed or when the potential for transmission of infection is of concern.

  10. Renal biopsy findings among Indigenous Australians: a nationwide review.

    Science.gov (United States)

    Hoy, Wendy E; Samuel, Terence; Mott, Susan A; Kincaid-Smith, Priscilla S; Fogo, Agnes B; Dowling, John P; Hughson, Michael D; Sinniah, Rajalingam; Pugsley, David J; Kirubakaran, Meshach G; Douglas-Denton, Rebecca N; Bertram, John F

    2012-12-01

    Australia's Indigenous people have high rates of chronic kidney disease and kidney failure. To define renal disease among these people, we reviewed 643 renal biopsies on Indigenous people across Australia, and compared them with 249 biopsies of non-Indigenous patients. The intent was to reach a consensus on pathological findings and terminology, quantify glomerular size, and establish and compare regional biopsy profiles. The relative population-adjusted biopsy frequencies were 16.9, 6.6, and 1, respectively, for Aboriginal people living remotely/very remotely, for Torres Strait Islander people, and for non-remote-living Aboriginal people. Indigenous people more often had heavy proteinuria and renal failure at biopsy. No single condition defined the Indigenous biopsies and, where biopsy rates were high, all common conditions were in absolute excess. Indigenous people were more often diabetic than non-Indigenous people, but diabetic changes were still present in fewer than half their biopsies. Their biopsies also had higher rates of segmental sclerosis, post-infectious glomerulonephritis, and mixed morphologies. Among the great excess of biopsies in remote/very remote Aborigines, females predominated, with younger age at biopsy and larger mean glomerular volumes. Glomerulomegaly characterized biopsies with mesangiopathic changes only, with IgA deposition, or with diabetic change, and with focal segmental glomerulosclerosis (FSGS). This review reveals great variations in biopsy rates and findings among Indigenous Australians, and findings refute the prevailing dogma that most indigenous renal disease is due to diabetes. Glomerulomegaly in remote/very remote Aboriginal people is probably due to nephron deficiency, in part related to low birth weight, and probably contributes to the increased susceptibility to kidney disease and the predisposition to FSGS.

  11. Documenting the location of prostate biopsies with image fusion

    Science.gov (United States)

    Turkbey, Baris; Xu, Sheng; Kruecker, Jochen; Locklin, Julia; Pang, Yuxi; Bernardo, Marcelino; Merino, Maria J.; Wood, Bradford J.; Choyke, Peter L.; Pinto, Peter A.

    2012-01-01

    OBJECTIVE To develop a system that documents the location of transrectal ultrasonography (TRUS)-guided prostate biopsies by fusing them to MRI scans obtained prior to biopsy, as the actual location of prostate biopsies is rarely known. PATIENTS AND METHODS Fifty patients (median age 61) with a median prostate-specific antigen (PSA) of 5.8 ng/ml underwent 3T endorectal coil MRI prior to biopsy. 3D TRUS images were obtained just prior to standard TRUS-guided 12-core sextant biopsies wherein an electromagnetic positioning device was attached to the needle guide and TRUS probe in order to track the position of each needle pass. The 3D-TRUS image documenting the location of each biopsy was fused electronically to the T2-weighted MRI. Each biopsy needle track was marked on the TRUS images and these were then transposed onto the MRI. Each biopsy site was classified pathologically as positive or negative for cancer and the Gleason score was determined. RESULTS The location of all (n = 605) needle biopsy tracks was successfully documented on the T2-weighted (T2W) MRI. Among 50 patients, 20 had 56 positive cores. At the sites of biopsy, T2W signal was considered ‘positive’ for cancer (i.e. low in signal intensity) in 34 of 56 sites. CONCLUSION It is feasible to document the location of TRUS-guided prostate biopsies on pre-procedure MRI by fusing the pre-procedure TRUS to an endorectal coil MRI using electromagnetic needle tracking. This procedure may be useful in documenting the location of prior biopsies, improving quality control and thereby avoiding under-sampling of the prostate as well as directing subsequent biopsies to regions of the prostate not previously sampled. PMID:20590543

  12. Endomyocardial biopsy in heart transplantation: schedule or event?

    Science.gov (United States)

    Chi, N-H; Chou, N-K; Tsao, C-I; Huang, S-C; Wu, I-H; Yu, H-Y; Chen, Y-S; Wang, S-S

    2012-05-01

    Endomyocardial biopsy is the gold standard to identify rejection after heart transplantation. Due to its invasiveness, discomfort, and difficult vascular access, some patients are not willing to accept routine scheduled biopsies years after heart transplantation. The purpose of this study was to identify whether there was a difference in outcomes among the scheduled versus event biopsy groups. We studied 411 patients who underwent heart transplantation from 1987 to 2011, reviewing biopsy results and pathology reports. There were 363 patients who followed the scheduled biopsy protocol, and 48 patients who were assigned to the event biopsy group. We extracted data on biopsy results, rejection episodes, rejection types, and survival time. The 2481 reviewed biopsies over 24 years, showed most rejection episodes (86.4%) to occur within 2 years after heart transplantation. The rejection incidence was low (2.1%) at 3 years after transplantation. The major reason for an event biopsy was poor vascular access, such as tiny central vein or congenital disease without a suitable central vein. Event biopsy group patients were younger than schedule biopsy patients (19.7 years old vs 47.6 years old; P biopsy group (P = .029). The 10-year rates of freedom from rejection were similar. The rejection rate was low after 3 years; episodes occurred within 2 years. Although the long-term survival in the event group was better, they had a younger man age. The rejection and freedom from rejection rates were similar. As the rejection rate was low at 3 years after transplantation, we suggest that the event principle could be applied for biopsy at 3 years after heart transplantation. Copyright © 2012 Elsevier Inc. All rights reserved.

  13. Effect of Repeated Food Morsel Splitting on Jaw Muscle Control

    DEFF Research Database (Denmark)

    A, Kumar; Svensson, Krister G; Baad-Hansen, Lene

    2014-01-01

    Mastication is a complex motor task often initiated by splitting of the food morsel between the anterior teeth. Training of complex motor tasks has consistently been shown to trigger neuroplastic changes in corticomotor control and optimization of muscle function. It is not known if training...... and repeated food morsel splitting lead to changes in jaw muscle function. Objective: To investigate if repeated splitting of food morsels in participants with natural dentition changes the force and jaw muscle electromyographic (EMG) activity. Methods: Twenty healthy volunteers (mean age = 26.2 ± 3.9 years......) participated in a single one-hour session divided into six series. Each series consisted of ten trials of a standardized behavioral task (total of 60 trials). The behavioral task was to hold and split a food morsel (8 mm, 180 mg placebo tablet) placed on a bite force transducer with the anterior teeth...

  14. Analysis of repeated measures data

    CERN Document Server

    Islam, M Ataharul

    2017-01-01

    This book presents a broad range of statistical techniques to address emerging needs in the field of repeated measures. It also provides a comprehensive overview of extensions of generalized linear models for the bivariate exponential family of distributions, which represent a new development in analysing repeated measures data. The demand for statistical models for correlated outcomes has grown rapidly recently, mainly due to presence of two types of underlying associations: associations between outcomes, and associations between explanatory variables and outcomes. The book systematically addresses key problems arising in the modelling of repeated measures data, bearing in mind those factors that play a major role in estimating the underlying relationships between covariates and outcome variables for correlated outcome data. In addition, it presents new approaches to addressing current challenges in the field of repeated measures and models based on conditional and joint probabilities. Markov models of first...

  15. Needle core biopsy for breast lesions: An audit of 467 needle core biopsies

    Directory of Open Access Journals (Sweden)

    Selvi Radhakrishna

    2013-01-01

    Full Text Available Background: Breast cancer is the commonest cancer among women in urban India. Triple assessment includes clinical, radiological and cytological assessment of breast lesions. Guided core needle biopsy has replaced fine needle aspiration cytology in most of the western countries. In resource poor countries FNAC is still a very valuable and cost effective method to diagnose breast lesions. Pitfalls include increased rates of non diagnostic smears, and inadequate smears. Further procedures may be required and this increases the cost, anxiety and delay in diagnosis. Aims: The aim of this study is to analyze the concordance of radiological and histopathology findings in BI-RADS category 3,4,5 lesions following a core biopsy. Materials and Methods: Data was retrospectively collected from consecutive symptomatic and opportunistic screen detected patients with abnormalities who underwent ultrasound guided interventional procedures from Jan 2010 to Aug 2011. Symptomatic patients underwent clinical examination, mammogram and breast ultrasound. Women under 35 years of age had only breast ultrasound. Core biopsy was performed under ultrasound guidance or clinically by a breast surgeon/ radiologist for BI-RADS category 3,4,5 lesions. Statistical Methods: Chi square test was done to show the strength of association of imaging findings and histopathology results of core biopsy. Results: 437 patients were symptomatic and 30 patients had screen detected abnormalities. The positive predictive value for BI-RADS 5 lesions for malignancy is 93.25% and the negative predictive value of BI-RADS category 3 lesions for cancer is 98.4%. False negative diagnosis on core biopsy was 0.85%. We were able to defer surgery in 60% of the patients with a clear radiological and pathological benign diagnosis. Conclusion: The PPV and NPV for cancer is high with needle core biopsy in BI-RADS 3,4,5 lesions. Where there is no discordance between clinical, radiology and pathology findings

  16. Session: Program Review X Wrap-Up

    Energy Technology Data Exchange (ETDEWEB)

    None

    1992-01-01

    This wrap-up session at the Geothermal Energy Program Review X: Geothermal Energy and the Utility Market consisted of Closing Remarks by Roland R. Kessler and six NGA Industry Critique Panel presentations: ''Summary of Comments on DOE-Industry Cooperation by Geothermal Industry Panel'' by James B. Koenig, GeothermEx, Inc.; ''NGA Industry Critique of the Exploration Component'' by Joe L. Iovenitti, Weiss Associates; ''Critique of Drilling Research'' by Jerry Hamblin, UNOCAL Geothermal; ''Critique Panel Comments on Reservoir Engineering, DOE Geothermal Technology Development'' by Dennis Kaspereit, California Energy Company, Inc.; ''DOE Geothermal Program Review - Critique on Production'' by Douglas B. Jung, Two-Phase Engineering and Research; ''Comments on the DOE Hydrothermal Energy Conversion R&D Program'' by David L. Mendive, Geothermal Development Associates.

  17. Ecole de Physique des Houches: session 96

    CERN Document Server

    Huard, Benjamin; Schoelkopf, Robert; Cugliandolo, Leticia F; Quantum Machines : Measurement and Control of Engineered Quantum Systems

    2014-01-01

    This book gathers the lecture notes of courses given at the 2011 summer school in theoretical physics in Les Houches, France, Session XCVI. What is a quantum machine? Can we say that lasers and transistors are quantum machines? After all, physicists advertise these devices as the two main spin-offs of the understanding of quantum mechanical phenomena. However, while quantum mechanics must be used to predict the wavelength of a laser and the operation voltage of a transistor, it does not intervene at the level of the signals processed by these systems. Signals involve macroscopic collective variables like voltages and currents in a circuit or the amplitude of the oscillating electric field in an electromagnetic cavity resonator. In a true quantum machine, the signal collective variables, which both inform the outside on the state of the machine and receive controlling instructions, must themselves be treated as quantum operators, just as the position of the electron in a hydrogen atom. Quantum superconducting...

  18. Partners' session spurs progress for Latin women.

    Science.gov (United States)

    1982-02-18

    A workshop sponsored by Partners of the Americas with support from the US Agency for International Development's Women in Development Office held in Christiana, Jamaica, October 1981 was designed to expand the involvement of women in the development process by strengthening leadership capabilities of women in the Caribbean. Sessions were held on project planning, goal identification, and resource evaluation. By the end of the workshop women representing 11 US states and their partners in 17 Latin American and Caribbean countries had initiated several projects. Some projects are: 1) Colombia-Florida: developing literacy training aids about nutrition information, 2) Guatemala-Alabama: home gardening and nutrition education, and 3) Jamaica-western New York: skills training programs for young mothers.

  19. Precise subtyping for synchronous multiparty sessions

    Directory of Open Access Journals (Sweden)

    Mariangiola Dezani-Ciancaglini

    2016-02-01

    Full Text Available The notion of subtyping has gained an important role both in theoretical and applicative domains: in lambda and concurrent calculi as well as in programming languages. The soundness and the completeness, together referred to as the preciseness of subtyping, can be considered from two different points of view: operational and denotational. The former preciseness has been recently developed with respect to type safety, i.e. the safe replacement of a term of a smaller type when a term of a bigger type is expected. The latter preciseness is based on the denotation of a type which is a mathematical object that describes the meaning of the type in accordance with the denotations of other expressions from the language. The result of this paper is the operational and denotational preciseness of the subtyping for a synchronous multiparty session calculus. The novelty of this paper is the introduction of characteristic global types to prove the operational completeness.

  20. Seamless Video Session Handoff between WLANs

    Directory of Open Access Journals (Sweden)

    Claudio de Castro Monteiro

    2010-01-01

    Full Text Available Handoff in a distributed IEEE 802.11 Wireless LAN network is a source of significant amount of problems on the video transmission environment. The visual quality of video streaming applications is lowered when stations are in handoff status. In this paper, we introduce an architecture of a session proxy (SP, which tries to preserve the quality of the streaming video upon each handoff between access points. We have evaluated thresholds of RSSI and Loss Frame Rate (LFR for deciding the moment when the handoff process shall begin. Our solution performance was evaluated in a testbed implementation for MPEG-4 video on demand with one video server (VLS and two FreeBSD-based access points supporting Mobile IP, DHCP Server and IAPP approach.

  1. Affective Adaptation to Repeated SIT and MICT Protocols in Insulin Resistant Subjects.

    Science.gov (United States)

    Saanijoki, Tiina; Nummenmaa, Lauri; Koivumäki, Mikko; Löyttyniemi, Eliisa; Kalliokoski, Kari K; Hannukainen, Jarna C

    2017-08-29

    The aim of this study was to investigate affective responses to repeated sessions of sprint interval training (SIT) in comparison with moderate-intensity continuous training (MICT) in insulin resistant subjects. Twenty-six insulin resistant adults (age: 49 (4) years, 10 women) were randomized into SIT (n=13) or MICT (n=13) groups. Subjects completed six supervised training sessions within 2 weeks (SIT session: 4-6 × 30 s all-out cycling/4-min recovery; MICT session: 40-60 min at 60% peak work load). Perceived exertion, stress and affective state were assessed with questionnaires prior to, during and after each training session. Perceived exertion, displeasure, and arousal were higher during the SIT compared with MICT sessions (all p SIT and MICT over the six days of training (all p SIT versus MICT exercise increased perceived stress and decreased positive affect and feeling of satisfaction acutely after exercise especially in the beginning of the intervention (all p 0.05). The perceptual and affective responses are more negative both during and acutely after SIT compared with MICT in untrained insulin resistant adults. These responses, however, show significant improvements already within six training sessions indicating rapid positive affective and physiological adaptations to continual exercise training, both SIT and MICT. These findings suggest that even very intense SIT is mentally tolerable alternative for untrained people with insulin resistance.

  2. Mortality and complications after prostate biopsy in the Prostate, Lung, Colorectal and Ovarian Cancer Screening (PLCO) trial.

    Science.gov (United States)

    Pinsky, Paul F; Parnes, Howard L; Andriole, Gerald

    2014-02-01

    To examine mortality and morbidity after prostate biopsy in the intervention arm of the Prostate, Lung, Colorectal and Ovarian Cancer Screening (PLCO) trial. Abstractors from the PLCO trial recorded the types and dates of diagnostic follow-up procedures after positive screens and documented the types and dates of resultant complications. Cancers and deaths among the participants were tracked. The mortality rate in the 120-day period after prostate biopsy was compared with a control rate of deaths in the 120-day period after a negative screen in men without biopsy. Multivariate analysis was performed to control for potential confounders, including age, comorbidities and smoking. Rates of any complication, infectious and non-infectious complications were computed among men with a negative biopsy. Multivariate analysis was used to examine the risk factors for complications. Of the 37,345 men enrolled in the PLCO trial (intervention arm), 4861 had at least one biopsy after a positive screen and 28,661 had a negative screen and no biopsy. The 120-day mortality rate after biopsy was 0.95 (per 1000), compared with the control group rate of 1.8; the multivariate relative risk was 0.49 (95% CI: 0.2-1.1). Among 3706 negative biopsies, the rates (per 1000) of any complication, infectious and non-infections complications were 20.2, 7.8 and 13.0, respectively. A history of prostate enlargement or inflammation was significantly associated with higher rates of both infectious (odds ratio [OR] = 3.7) and non-infectious (OR = 2.2) complications. Black race was associated with a higher infectious complications rate (OR = 7.1) and repeat biopsy was associated with lower rates of non-infectious complications (OR = 0.3). Mortality rates were not found to be higher after prostate biopsy in the PLCO trial and complications were relatively infrequent, with several risk factors identified. Published 2013. This article has been contributed to by US Government employees and their work is in

  3. AAS Special Session: Policy Making in Astronomy

    Science.gov (United States)

    Cardelli, J. A.; Massa, D.

    1995-12-01

    The professional astronomical community today is more diverse than at any time in its history. Individuals participating in creative research programs can be found in a wide range of positions. This type of diversity, which mixes research, education, and service (e.g. contract) work, represents the strength of contemporary astronomy. While recognizing the unavoidable reductions in funding and restructuring of organizations like NASA, it is imperative that the significance of the current diversity be considered during these processes. Creative ideas are one of the cornerstones of quality research, and they can originate anywhere. Consequently, it is essential that adequate research resources remain available for free and open competition by all astronomers. Our goal in this session is to bring together officials from the AAS, NASA, and the NSF to discuss how the policy and decision making process operates and whether it should be changed to better serve the general needs of the professional astronomical community. Examples of the issues we believe are important include: In establishing new policy, how can the needs of the average research astronomer be better addressed? How could input from such astronomers be provided to those who craft NASA/NSF policy? How can/should the AAS serve as an interface between policy/decision making bodies and its membership? Should the AAS membership become more actively/effectively involved in the decision making process and, if so, how? More information on this session and related issues can be found at the Association of Research Astronomers Home Page: http://www.phy.vill.edu/astro/faculty/ara/ara_home.htm

  4. Factors that can minimize bleeding complications after renal biopsy

    OpenAIRE

    Zhu, M. S.; J. Z. Chen; A.P. Xu

    2014-01-01

    Renal biopsy is a very important diagnostic tool in the evaluation of renal diseases. However, bleeding remains to be one of the most serious complications in this procedure. Many new techniques have been improved to make it safer. The risk factors and predictors of bleeding after percutaneous renal biopsy have been extensively reported in many literatures, and generally speaking, the common risk factors for renal biopsy complications focus on hypertension, high serum creatinine, bleeding dia...

  5. Quantitative morphology and water distribution of bronchial biopsy samples.

    OpenAIRE

    Baldwin, D. R.; Wise, R.; Andrews, J. M.; HONEYBOURNE, D

    1992-01-01

    BACKGROUND: An approach to the study of the pharmacokinetics of drugs in the lung is to measure their concentrations in bronchial biopsy specimens. The main criticism of this technique is that bronchial biopsy specimens consist of more than one tissue type and that drugs are often not distributed evenly. The morphology of bronchial biopsy specimens and the distribution of water between the extracellular and the intracellular compartments is therefore important. METHODS: Fifteen subjects under...

  6. Utility of repeat cytological assessment of thyroid nodules initially classified as benign: clinical insights from multidisciplinary care in an Irish tertiary referral centre.

    Science.gov (United States)

    Glynn, Nigel; Hannon, Mark J; Lewis, Sarah; Hillery, Patrick; Al-Mousa, Mohammed; Hill, Arnold D K; Keeling, Frank; Morrin, Martina; Thompson, Christopher J; Smith, Diarmuid; Royston, Derval; Leader, Mary; Agha, Amar

    2016-08-02

    Fine needle aspiration biopsy (FNAB) is the tool of choice for evaluating thyroid nodules with the majority classified as benign following initial assessment. However, concern remains about false negative results and some guidelines have recommended routine repeat aspirates. We aimed to assess the utility of routine repeat FNAB for nodules classified as benign on initial biopsy and to examine the impact of establishing a multidisciplinary team for the care of these patients. We performed a retrospective review of 400 consecutive patients (413 nodules) who underwent FNAB of a thyroid nodule at our hospital between July 2008 and July 2011. Data recorded included demographic, clinical, histological and radiological variables. Three hundred and fifty seven patients (89 %) were female. Median follow-up was 5.5 years. Two hundred and fifty eight (63 %) nodules were diagnosed as benign. The rate of routine repeat biopsy increased significantly over the time course of the study (p for trend = 0.012). Nine Thy 2 nodules were classified differently on the basis of routine repeat biopsy; one patient was classified as malignant on repeat biopsy and was diagnosed with papillary thyroid carcinoma. Eight were classified as a follicular lesions on repeat biopsy-six diagnosed as benign following lobectomy; two declined lobectomy and were followed radiologically with no nodule size increase. The false negative rate of an initial benign cytology result, from a thyroid nodule aspirate, is low. In the setting of an experienced multidisciplinary thyroid team, routine repeat aspiration is not justified.

  7. Targeted cryotherapy using disposable biopsy punches

    Directory of Open Access Journals (Sweden)

    Avitus John Raakesh Prasad

    2014-01-01

    Full Text Available Cryotherapy is a commonly used office procedure that causes destruction of tissue by cryonecrosis due to rapid freezing and thawing of cells. The limitation in treating plantar warts and deeper dermal lesions is that the freeze time should be longer to penetrate deeper, which results in collateral damage to normal skin surrounding the lesion. This results in unwanted side effects of prolonged pain, blistering and haemorrhage and increased healing time. The cone spray technique was used to reduce collateral damage, but deeper penetration is difficult to achieve. An innovative technique using disposable biopsy punches is described that ensures deeper freezing as compared to the plastic cone. The metal cutting edge of the punch enters deeper into the lesions as the liquid nitrogen is passed, sparing damage to surrounding skin.

  8. Targeted Cryotherapy Using Disposable Biopsy Punches

    Science.gov (United States)

    Prasad, Avitus John Raakesh

    2014-01-01

    Cryotherapy is a commonly used office procedure that causes destruction of tissue by cryonecrosis due to rapid freezing and thawing of cells. The limitation in treating plantar warts and deeper dermal lesions is that the freeze time should be longer to penetrate deeper, which results in collateral damage to normal skin surrounding the lesion. This results in unwanted side effects of prolonged pain, blistering and haemorrhage and increased healing time. The cone spray technique was used to reduce collateral damage, but deeper penetration is difficult to achieve. An innovative technique using disposable biopsy punches is described that ensures deeper freezing as compared to the plastic cone. The metal cutting edge of the punch enters deeper into the lesions as the liquid nitrogen is passed, sparing damage to surrounding skin. PMID:25136216

  9. Sentinel lymph node biopsy in oral cancer

    DEFF Research Database (Denmark)

    Thomsen, Jørn Bo; Sørensen, Jens Ahm; Grupe, Peter;

    2005-01-01

    PURPOSE: To validate lymphatic mapping combined with sentinel lymph node biopsy as a staging procedure, and to evaluate the possible clinical implications of added oblique lymphoscintigraphy and/or tomography and test the intra- and interobserver reproducibility of lymphoscintigraphy. MATERIAL...... AND METHODS: Forty patients (17 F and 23 M, aged 32-90) with 24 T1 and 16 T2 squamous cell carcinoma of the oral cavity. Planar lymphoscintigraphy, emission and transmission tomography were performed. Detection and excision of the sentinel nodes were guided by a gamma probe. The sentinel nodes were step......-sectioning and stained with hematoxylin and eosin and cytokeratin (CK 1). Histology and follow-up were used as "gold standard". Tumor location, number of sentinel lymph nodes, metastasis, and recurrences were registered. Two observers evaluated the lymphoscintigraphic images to assess the inter-rater agreement. RESULTS...

  10. Atopic dermatitis. Findings of skin biopsies.

    Science.gov (United States)

    Piloto Valdés, L; Gómez Echevarría, A H; Valdés Sánchez, A F; Ochoa Ochoa, C; Chong López, A; Mier Naranjo, G

    1990-01-01

    Twenty-eight adult patients with a clinical diagnosis of atopic dermatitis (according to the criteria of Hanifin and Lobitz) were studied at the Allergy Outpatient Service, the Dermatology Service and the Pathological Anatomy Service of the Hermanos Ameijeiras Clinical Surgical Hospital, from January to September 1986. The patients were submitted to a quantification of total serum IgE by means of the ELISA enzymatic ultramicromethod, developed at the Radioimmunoassay National Center, and skin biopsies were carried out by means of the paraffin and direct immunofluorescence methods. The most frequent histopathological findings were acanthosis, espongiosis, parakeratosis and exocitosis, as a chronic inflammatory infiltrate, mainly composed of lymphocytes, mast cells and eosinophils. In the skin direct immunofluorescence method we found depots of IgE in all the patients, having no relation in intensity to total serum IgE values.

  11. Fine needle aspiration biopsy of ophthalmic tumors☆

    Science.gov (United States)

    Singh, Arun D.; Biscotti, Charles V.

    2012-01-01

    A majority of intraocular tumors can be diagnosed based on clinical examination and ocular imaging studies, which obviate the need for diagnostic ophthalmic fine needle aspiration biopsy (FNAB). Overall, diagnostic accuracy of ophthalmic FNAB is high but limited cellularity can compromise the diagnostic potential of ophthalmic aspirate samples. The role of ophthalmic FNAB is limited in retinal tumors. Orbital FNAB should be considered in the evaluation of lacrimal gland tumors, orbital metastasis, and lymphoproliferative lesions. Negative cytologic diagnosis of malignancy should not be considered unequivocal proof that an intraocular malignancy does not exist. With improved understanding of genetic prognostic factors of uveal melanoma, ophthalmic FNAB is gaining popularity for prognostic purposes in combination with eye conserving treatment of the primary tumor. In special clinical indications, ancillary studies such as immunohistochemistry and FISH can be performed on ophthalmic FNAB samples. Assistance of an experienced cytopathologist cannot be overemphasized. PMID:23960981

  12. Confocal Microscopy in Biopsy Proven Argyrosis

    Directory of Open Access Journals (Sweden)

    Melis Palamar

    2013-01-01

    Full Text Available Purpose. To evaluate the confocal microscopy findings of a 46-year-old male with bilateral biopsy proven argyrosis. Materials and Methods. Besides routine ophthalmologic examination, anterior segment photography and confocal microscopy with cornea Rostoch module attached to HRT II (Heidelberg Engineering GmbH, Heidelberg, Germany were performed. Findings. Squamous metaplastic changes on conjunctival epithelium and intense highly reflective extracellular punctiform deposits in conjunctival substantia propria were detected. Corneal epithelium was normal. Highly reflective punctiform deposits starting from anterior to mid-stroma and increasing through Descemet’s membrane were evident. Corneal endothelium could not be evaluated due to intense stromal deposits. Conclusion. Confocal microscopy not only supports diagnosis in ocular argyrosis, but also demonstrates the intensity of the deposition in these patients.

  13. Status quo and development trend of breast biopsy technology

    National Research Council Canada - National Science Library

    Zhang, Yan-Jun; Wei, Lichun; Li, Jie; Zheng, Yi-Qiong; Li, Xi-Ru

    2013-01-01

    .... With the continuous advancement of diagnostic and treatment technology for breast cancer, collection of diseased tissue has also undergone a gradual transition from traditional open surgery to biopsy...

  14. Clinicopathological Evaluation of the Kidney Biopsies: Our Center's Experience

    Directory of Open Access Journals (Sweden)

    Serhan PİŞKİNPAŞA

    2012-05-01

    Full Text Available OBJECTIVES: Kidney biopsy is a valuable tool for both diagnosis and to guide treatment of renal diseases. In this report, we aimed both clinical and pathological evaluation of the kidney biopsies in our institution. MATERIAL and METHODS: Kidney biopsies in adult patients performed between 2002-2011 at the Department of Nephrology were analyzed. Biopsies were performed with the guidance of ultrasonography, and 16 and 18 G needles for two cores were used. At least seven glomeruli and one artery was accepted as adequate for diagnosis. RESULTS: Five hundred thirty six kidney biopsy reports was evaluated. The mean age of the patients at presentation was 42.80±16.66 years (16-85 years old, and 55.4% of the patients was male. The most frequent indication of the kidney biopsies were nephrotic range proteinuria with 63.43%. The most common histopathological diagnosis in primary and secondary glomerular diseases was membranous nephropathy (n=88, 16.4% and amyloidosis (n=96, 17.9% respectively. The most frequent diagnosis of the biopsies performed due to acute kidney injury was rapidly progressing glomerulonephritis (n=20, 3.7%. The major complication rate was low (0.18%. CONCLUSION: Nephrotic range proteinuria was the most frequent indication for the kidney biopsy in our institution. Membranous nephropathy and amyloidosis were the most frequent primary and secondary glomerular diseases. Complication rate in percutaneous kidney biopsy with the guidance of ultrasonography is low.

  15. Transvenous Renal Transplant Biopsy via a Transfemoral Approach.

    Science.gov (United States)

    Schmid, A; Jacobi, J; Kuefner, M A; Lell, M; Wuest, W; Mayer-Kadner, I; Benz, K; Schmid, M; Amann, K; Uder, M

    2013-05-01

    Percutaneous renal biopsy (PRB) of kidney transplants might be prevented by an elevated risk of bleeding or limited access to the allograft. In the following, we describe our initial experience with 71 transvenous renal transplant biopsies in 53 consecutive patients with unexplained reduced graft function who were considered unsuitable candidates for PRB (4.2% of all renal transplant biopsies at our institution). Biopsies were performed via the ipsilateral femoral vein with a renal biopsy set designed for transjugular renal biopsy (TJRB) of native kidneys. Positioning of the biopsy system within the transplant vein was achievable in 58 of 71 (81.7%) procedures. The specimen contained a median of 10 glomeruli (range 0-38). Tissue was considered as adequate for diagnosis in 56 of 57 (98.2%) biopsies. With respect to BANFF 50.9% of the specimen were adequate (>10 glomeruli), 47.4% marginally adequate (1-9 glomeruli) and 1.8% inadequate (no glomeruli). After implementation of real-time assessment all specimen contained glomeruli. One of the fifty-eight (1.8%) procedure-related major complications occurred (hydronephrosis requiring nephrostomy due to gross hematuria). Transfemoral renal transplant biopsy (TFRTB) is feasible and appears to be safe compared to PRB. It offers a useful new alternative for histological evaluation of graft dysfunction in selected patients with contraindications to PRB.

  16. Preservative solution for skeletal muscle biopsy samples

    Science.gov (United States)

    Kurt, Yasemin Gulcan; Kurt, Bulent; Ozcan, Omer; Topal, Turgut; Kilic, Abdullah; Muftuoglu, Tuba; Acikel, Cengizhan; Sener, Kenan; Sahiner, Fatih; Yigit, Nuri; Aydin, Ibrahim; Alay, Semih; Ekinci, Safak

    2015-01-01

    Context: Muscle biopsy samples must be frozen with liquid nitrogen immediately after excision and maintained at -80°C until analysis. Because of this requirement for tissue processing, patients with neuromuscular diseases often have to travel to centers with on-site muscle pathology laboratories for muscle biopsy sample excision to ensure that samples are properly preserved. Aim: Here, we developed a preservative solution and examined its protectiveness on striated muscle tissues for a minimum of the length of time that would be required to reach a specific muscle pathology laboratory. Materials and Methods: A preservative solution called Kurt-Ozcan (KO) solution was prepared. Eight healthy Sprague-Dawley rats were sacrificed; striated muscle tissue samples were collected and divided into six different groups. Muscle tissue samples were separated into groups for morphological, enzyme histochemical, molecular, and biochemical analysis. Statistical method used: Chi-square and Kruskal Wallis tests. Results: Samples kept in the KO and University of Wisconsin (UW) solutions exhibited very good morphological scores at 3, 6, and 18 hours, but artificial changes were observed at 24 hours. Similar findings were observed for the evaluated enzyme activities. There were no differences between the control group and the samples kept in the KO or UW solution at 3, 6, and 18 hours for morphological, enzyme histochemical, and biochemical features. The messenger ribonucleic acid (mRNA) of β-actin gene was protected up to 6 hours in the KO and UW solutions. Conclusion: The KO solution protects the morphological, enzyme histochemical, and biochemical features of striated muscle tissue of healthy rats for 18 hours and preserves the mRNA for 6 hours. PMID:26019417

  17. Preservative solution for skeletal muscle biopsy samples

    Directory of Open Access Journals (Sweden)

    Yasemin Gulcan Kurt

    2015-01-01

    Full Text Available Context : Muscle biopsy samples must be frozen with liquid nitrogen immediately after excision and maintained at -80 o C until analysis. Because of this requirement for tissue processing, patients with neuromuscular diseases often have to travel to centers with on-site muscle pathology laboratories for muscle biopsy sample excision to ensure that samples are properly preserved. Aim: Here, we developed a preservative solution and examined its protectiveness on striated muscle tissues for a minimum of the length of time that would be required to reach a specific muscle pathology laboratory. Materials and Methods: A preservative solution called Kurt-Ozcan (KO solution was prepared. Eight healthy Sprague-Dawley rats were sacrificed; striated muscle tissue samples were collected and divided into six different groups. Muscle tissue samples were separated into groups for morphological, enzyme histochemical, molecular, and biochemical analysis. Statistical method used: Chi-square and Kruskal Wallis tests. Results: Samples kept in the KO and University of Wisconsin (UW solutions exhibited very good morphological scores at 3, 6, and 18 hours, but artificial changes were observed at 24 hours. Similar findings were observed for the evaluated enzyme activities. There were no differences between the control group and the samples kept in the KO or UW solution at 3, 6, and 18 hours for morphological, enzyme histochemical, and biochemical features. The messenger ribonucleic acid (mRNA of β-actin gene was protected up to 6 hours in the KO and UW solutions. Conclusion: The KO solution protects the morphological, enzyme histochemical, and biochemical features of striated muscle tissue of healthy rats for 18 hours and preserves the mRNA for 6 hours.

  18. Role of bone biopsy in renal osteodystrophy

    Directory of Open Access Journals (Sweden)

    Al Badr Wisam

    2009-01-01

    Full Text Available Renal osteodystrophy (ROD, the abnormal bone histology that occurs in the context of kidney disease, is a disease spectrum and not a uniform progressive bone disease. It is an important component of the broad disturbances of bone and mineral metabolism associated with chronic kidney disease (CKD. There are multiple pathogenetic factors which contribute to the histological abnormalities seen on bone biopsy. The patients with ROD are rarely symp-tomatic in the early stages of CKD. It is also noteworthy that the clinical manifestations are usually preceded by biochemical changes that are insidious and subtle. This makes it difficult for the clinician to suspect the presence of bone and mineral metabolism abnormalities without direct testing. The serum calcium, phosphorus, and alkaline phosphatase levels are usually normal until late in the course of CKD. The main screening test for abnormal bone and mineral metabolism is the measurement of parathyroid hormone which is also somewhat delayed. The clinical signs and symptoms are also challenging to interpret because of their slow and non-specific nature which may include vague, ill-defined, bone aches and pains, and muscle weakness. The gold standard for diagnosis of ROD is bone biopsy with mineralized bone histology after double tetracycline labeling, iron staining and aluminum staining. The currently used histomorphometric descriptions of bone histology are not well integrated clinically and a new nomenclature that is clinically more relevant and useful has been proposed. Additional studies are required to define the spectrum of ROD in the current therapeutic era, and to find clinically useful non-invasive biomarkers to improve the treatment and monitoring of the abnormal bone in the setting of CKD.

  19. A new instrument for rectal suction biopsy in the diagnosis of Hirschsprung′s disease: Triple rectal suction biopsy

    Directory of Open Access Journals (Sweden)

    Barlas Meral

    2006-01-01

    Full Text Available A new instrument for suction rectal biopsy in infants suspected of having Hirschsprung′s disease is described that can be completely dismantled, physically cleaned, lubricated, and heat sterilised. Triple rectal suction biopsy instrument with the patent application, which involves (0.5 cm diameter suction of mucosa and sub-mucosa and provides taking three different biopsies within a 2 cm distant from each other with a single shot, instead of only one or taking a full layer biopsy under general anesthesia for the diagnosis of Hirschsprung disease. As a preliminary study, in the 36 and 12 biopsy materials taken from the rabbits and children, respectively, it was found that mucosa and sub-mucosa were sufficient and in all of the cross sections, parasympathetic nerve fibers, and ganglion cells were existed. A successful biopsy was usually achieved and no complications occurred.

  20. Effect of a yoga practice session and a yoga theory session on state anxiety.

    Science.gov (United States)

    Telles, Shirley; Gaur, Vaishali; Balkrishna, Acharya

    2009-12-01

    Yoga techniques practiced for varying durations have been shown to reduce state anxiety. In this study, there were 300 naive-to-yoga persons of both sexes who were attending a yoga therapy center in north India for stress relief as day visitors and were not residing at the center. They were assigned to two groups, yoga practice and yoga theory, and their state anxiety was assessed before and after a 2-hr. yoga session. A significant reduction in scores on state anxiety was found in the yoga practice group (14.7% decrease), as well as in the yoga theory group (3.4% decrease). The difference in scores following the sessions was statistically significant. Hence, yoga practice as well as learning about theoretical aspects of yoga appear to reduce state anxiety, with a greater reduction following yoga practice.

  1. Linking Competency with Training Needs: Session Summary on Disaster Studies and Evaluation, Session BO-17.

    Science.gov (United States)

    Ling, Kelvin W K; Daily, Elaine K

    2016-02-01

    This section of Prehospital and Disaster Medicine (PDM) presents reports and summaries of the 19th World Congress on Disaster and Emergency Medicine (WCDEM) held in Cape Town, South Africa in April of 2015. Abstracts of Congress oral and poster presentations were published in April 2015 as a supplement to PDM (Volume 30, Supplement 1). Reports and session summaries of the 19th World Congress on Disaster and Emergency Medicine.

  2. A successful case of liver biopsy via the right femoral vein using the Quick-Core biopsy needle.

    Science.gov (United States)

    Michimoto, Kenkichi; Shimizu, Kanichiro; Kameoka, Yoshihiko; Kurata, Naoki; Tokashiki, Tadashi; Sadaoka, Shunichi; Fukuda, Kunihiko

    2015-05-01

    A 35-year-old male with ascites and coagulopathy underwent transjugular liver biopsy (TJLB) for severe hepatic dysfunction. However, the acute angle of the inferior vena cava and hepatic veins (HVs) prevented insertion of a 14-gauge inner stiffening metallic cannula into the HV. He then underwent successful liver biopsy by right femoral vein access (transfemoral liver biopsy) using a TJLB device without complications and was pathologically diagnosed with nonalcoholic steatohepatitis.

  3. Freehand versus guided breast biopsy: comparison of accuracy, needle motion, and biopsy time in a tissue model.

    Science.gov (United States)

    Bluvol, Nathan; Kornecki, Anat; Shaikh, Allison; Del Rey Fernandez, David; Taves, Donald H; Fenster, Aaron

    2009-06-01

    Freehand ultrasound-guided breast biopsy may present difficulties in needle visualization within the scanning plane of the ultrasound image. Scanning plane and needle misalignment, an unknown needle insertion site (relative to the ultrasound image), needle trajectory before insertion, and physician experience play roles in the difficulty of these biopsy procedures. The objective of our study was to compare the currently used freehand technique with the use of a needle guidance system that limits needle motion to within the ultrasound scanning plane for breast biopsy. We developed a needle guidance system for breast biopsy that is composed of an electronically tracked passive mechanical arm and braking mechanism. The system was attached to an ultrasound transducer, and biopsy needles were inserted through the guidance arm. Both experienced and inexperienced radiologists performed ultrasound-guided biopsy on simulated breast lesions with and without the guidance system. Success rates were scored on the basis of the presence of lesions in the core biopsy samples. The biopsy procedures were analyzed using procedure time and total needle tip travel distance before firing. The biopsy success rates were greater using the guidance system (p < 0.05) than using the freehand technique. Experienced radiologists and inexperienced radiologists performed biopsy significantly faster using the needle guidance system (p < 0.001). Additionally, needle tip motion was significantly greater when using the freehand technique (p < 0.001) than using the guidance system. Biopsy using the developed needle guidance system is feasible and its use decreases procedure time and decreases needle motion; thus, it has the potential to reduce patient morbidity. Moreover, less operator experience is required for a successful breast biopsy using the needle guidance system than using the freehand technique.

  4. Use of core biopsy in diagnosing cervical lymphadenopathy: a viable alternative to surgical excisional biopsy of lymph nodes?

    Science.gov (United States)

    Allin, D; David, S; Jacob, A; Mir, N; Giles, A; Gibbins, N

    2017-03-01

    OBJECTIVES Lymphoma often presents with a neck mass and while fine-needle aspiration cytology may be suggestive, tissue biopsy is required for reliable diagnosis and classification of a lymphoma that is sufficient to deliver the correct treatment for the patient. Traditionally, excisional biopsy of a lymph node has been the standard method of tissue sampling, providing ample tissue for assessment. However, this requires theatre time, and preceding fine-needle aspiration cytology, which may incur a delay. With careful use of tissue, coupled with advances in immunohistochemical and molecular investigative techniques, core biopsy provides a possible alternative to traditional fine-needle aspiration and excisional biopsy. In this study, we aimed to determine the efficacy of diagnosing neck masses. METHOD A retrospective analysis was performed of patients being investigated for a neck mass who were undergoing ultrasound-guided core biopsies of cervical lymph nodes over a 17-month period. The final histology report was scrutinised to assess whether adequate tissue was obtained to allow for full tissue diagnosis. RESULTS Over the 17-month period analysed, 70 patients with cervical lymphadenopathy underwent core biopsy. Of these, 63 (90%) were diagnostic for either lymphoma or other pathology and did not require further tissue sampling. Overall, 19 patients were diagnosed with lymphoma, of which only 1 required further biopsy due to inconclusive initial core biopsy. CONCLUSIONS Current guidelines for investigating lymphomas require that excisional biopsy be performed to obtain ample tissue to allow full nodal architecture assessment and ancillary investigation to reach an accurate histological classification. Within our head and neck multidisciplinary team, however, it is considered that results from core biopsies can be obtained in a more timely fashion and with histological accuracy equal to those of open biopsy. The results obtained demonstrate that core biopsy is an

  5. Repeatability of Detecting Visual Cortex Activity in Functional Magnetic Resonance Imaging

    Directory of Open Access Journals (Sweden)

    Mahboubeh Ma'soumbeigi

    2012-03-01

    Full Text Available Introduction As functional magnetic resonance imaging (fMRI is too expensive and time consuming, its frequent implementation is difficult. The aim of this study is to evaluate repeatability of detecting visual cortex activity in fMRI. Materials and Methods In this study, 15 normal volunteers (10 female, 5 male; Mean age±SD: 24.7±3.8 years attended. Functional magnetic resonance images were obtained during a visual task of sine-wave with spatial frequency of 1.84 cpd and temporal frequency of 8 Hz in three scan runs. Two runs of functional images were provided consecutively in a session, and the third run was provided 1-6 weeks later. The activation map was created using the data obtained from the block-designed fMRI study. Voxels whose Z value was above a threshold of 2.3, at a significance level p=0.05, were considered activated. After image processing, the blood oxygen level dependent (BOLD signal changes and the number of activated voxels in response to visual stimuli were compared in different runs. Results The results of this study demonstrate no significant difference between the number of activated voxels and BOLD signal in first and second runs in one session (Paired t-test, p>0.05. Moreover, there is a considerable correlation between first and second scan runs (rsignal=0.74, p=0.006 and rvoxel=0.62, p=0.03, while the correlation between the runs in separate sessions is weak (rsignal=0.28, p=0.38 and rvoxel=0.32, p=0.31. Conclusion Since the repeatability of BOLD signal and number of activated voxels in one session is considerably better than that in the separate sessions, it is suggested that in fMRI visual studies that need repeated scanning, scans should be acquired during a single session.

  6. MR imaging-guided prostate biopsy: technical features and preliminary results.

    Science.gov (United States)

    Panebianco, Valeria; Barchetti, Flavio; Manenti, Guglielmo; Aversa, Tommaso; Catalano, Carlo; Simonetti, Giovanni

    2015-06-01

    Repeatedly negative prostate biopsies in individuals with elevated prostate-specific antigen (PSA) levels can be frustrating for both the patient and the urologist. This study was performed to investigate if magnetic resonance imaging (MRI)-guided transrectal biopsy (MRGB) increases diagnostic performance in individuals with suspected prostate cancer (PCa). Twenty-three consecutive men with a total PSA >4 ng/mL, PSA density >0.15, PSA velocity >0.75 ng/mL/year and suspicious MRI findings were included (average age 64 years; age range 53-75 years; total PSA levels ranging from 4.7 to 54 ng/mL; median 9 ng/mL). MRGB was performed with a closed unit at 1.5 Tesla, an MRI compatible biopsy device, a needle guide, and a titanium double-shoot biopsy gun. At prebiopsy MRI, in the 23 patients, a total of 26 suspicious areas to which the MRGB should be directed were found, 23 of them in the peripheral zone and three in the transitional zone. The needle guide was depicted and could be positioned with MRI guidance in all 23 patients. The duration of the procedure ranged from 35 to 55 min (mean 40 min). MRGB was well tolerated by all patients, and no major complications were observed. The detection rate for the diagnosis of PCa was 80, and 90 % of detected PCa were of intermediate aggressiveness. MRGB has the potential to improve cancer detection rates in men with suspected PCa to deliver the relevant treatment as soon as possible.

  7. Optical guidance for stereotactic brain tumor biopsy procedures: preliminary clinical evaluation (Conference Presentation)

    Science.gov (United States)

    Haj-Hosseini, Neda; Richter, Johan; Milos, Peter; Hallbeck, Martin; Wârdell, Karin

    2017-02-01

    In the routine of stereotactic biopsy on suspected tumors located deep in the brain or patients with multiple lesions, tissue samples are harvested to determine the type of malignancy. Biopsies are taken from pre-calculated positions based on the preoperative radiologic images susceptible to brain shift. In such cases the biopsy procedure may need to be repeated leading to a longer operation time. To provide guidance for targeting diagnostic tumor tissue and to avoid vessel rupture on the insertion path of the tumor, an application specific fiber optic probe was developed. The setup incorporated spectroscopy for 5-aminolevulinic acid induced protopophyrin IX (PpIX) fluorescence in the tumor and laser Doppler for measuring microvascular blood flow which recorded backscattered light (TLI) at 780 nm and blood perfusion. The recorded signals were compared to the histopathologic diagnosis of the tissue samples (n=16) and to the preoperative radiologic images. All together 146 fluorescence and 276 laser Doppler signals were recorded along 5 trajectories in 4 patients. On all occasions strong PpIX fluorescence peaks were visible during real-time guidance. Comparing the gliotic tumor marginal zone with the tumor, the PpIX (51 vs. 528 a.u., [0-1790], p 0.05) and blood perfusion (8.3 vs. 17 a.u., [0-254], p > 0.05) were not significantly different. In conclusion, the optical guidance probe made real-time tumor detection and vessel tracking possible during the stereotactic biopsy procedures. Moreover, the fluorescence and blood perfusion in the tumor could be studied at controlled positions in the brain and the tumor.

  8. Limitations on quantum key repeaters.

    Science.gov (United States)

    Bäuml, Stefan; Christandl, Matthias; Horodecki, Karol; Winter, Andreas

    2015-04-23

    A major application of quantum communication is the distribution of entangled particles for use in quantum key distribution. Owing to noise in the communication line, quantum key distribution is, in practice, limited to a distance of a few hundred kilometres, and can only be extended to longer distances by use of a quantum repeater, a device that performs entanglement distillation and quantum teleportation. The existence of noisy entangled states that are undistillable but nevertheless useful for quantum key distribution raises the question of the feasibility of a quantum key repeater, which would work beyond the limits of entanglement distillation, hence possibly tolerating higher noise levels than existing protocols. Here we exhibit fundamental limits on such a device in the form of bounds on the rate at which it may extract secure key. As a consequence, we give examples of states suitable for quantum key distribution but unsuitable for the most general quantum key repeater protocol.

  9. Effects of Learning on Performance When Computerized Dynamic Posturography Assessments Are Repeated

    Science.gov (United States)

    Taylor, Laura C.; Paloski, William H.; Wood, Scott J.

    2008-01-01

    Background: Computerized dynamic posturography is widely used to measure balance control performance. Clinically, performance is assessed by comparing individual data against standards obtained from a normative population. When performing repeated assessments to track performance changes, one must be concerned with the influence of learning effects. Subjects do not have the opportunity to practice before the first session, and often a second session is not performed prior to an experiment. Thus, the objective of this activity was to examine learning effects on balance control performance. We hypothesize that subjects will perform better on the second session when compared to the first, and that the difference will be greater for more difficult conditions. Methods: Data were collected from 204 subjects using the NeuroCom Equitest system during quiet stance with arms crossed at the chest on up to two sessions. All subjects performed standard sensory organization tests (SOTs) including 1) normal vision, fixed support; 2) absent vision, fixed support; 3) sway-referenced vision, fixed support; 4) normal vision, swayreferenced support; 5) absent vision, sway-referenced support; and 6) sway-referenced vision, sway-referenced support. 120 of these subjects performed modified sensory organization tests (mSOTs 2 and 5) which included static (20 back) and dynamic (20, 0.33Hz) head tilts. Median equilibrium scores (mEQ) were calculated from peak-to-peak anterior-posterior sway across trials. Data collected on the first session were then compared with the second to examine learning effect. Results: There were no differences in mEQ scores between the first and second sessions for SOTs 1, 2, and 4, while mEQ scores were higher for the second session when compared to the first for SOTs 3, 5, and 6 and for all mSOTs. Discussion: An additional familiarization session or practice trials prior to the first session may be necessary for more challenging SOT and mSOT conditions to

  10. Hysteresis of magnetostructural transitions: Repeatable and non-repeatable processes

    Energy Technology Data Exchange (ETDEWEB)

    Provenzano, Virgil [National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States); Della Torre, Edward; Bennett, Lawrence H. [Department of Electrical and Computer Engineering, The George Washington University, Washington, DC 20052 (United States); ElBidweihy, Hatem, E-mail: Hatem@gwmail.gwu.edu [Department of Electrical and Computer Engineering, The George Washington University, Washington, DC 20052 (United States)

    2014-02-15

    The Gd{sub 5}Ge{sub 2}Si{sub 2} alloy and the off-stoichiometric Ni{sub 50}Mn{sub 35}In{sub 15} Heusler alloy belong to a special class of metallic materials that exhibit first-order magnetostructural transitions near room temperature. The magnetic properties of this class of materials have been extensively studied due to their interesting magnetic behavior and their potential for a number of technological applications such as refrigerants for near-room-temperature magnetic refrigeration. The thermally driven first-order transitions in these materials can be field-induced in the reverse order by applying a strong enough field. The field-induced transitions are typically accompanied by the presence of large magnetic hysteresis, the characteristics of which are a complicated function of temperature, field, and magneto-thermal history. In this study we show that the virgin curve, the major loop, and sequentially measured MH loops are the results of both repeatable and non-repeatable processes, in which the starting magnetostructural state, prior to the cycling of field, plays a major role. Using the Gd{sub 5}Ge{sub 2}Si{sub 2} and Ni{sub 50}Mn{sub 35}In{sub 15} alloys, as model materials, we show that a starting single phase state results in fully repeatable processes and large magnetic hysteresis, whereas a mixed phase starting state results in non-repeatable processes and smaller hysteresis.

  11. Value of CT-guided core-needle biopsy in diagnosis and classification of malignant lymphomas using automated biopsy gun

    Institute of Scientific and Technical Information of China (English)

    Li Li; Qiu-Liang Wu; Li-Zhi Liu; Yun-Xian Mo; Chuan-Miao Xie; Lie Zheng; Lin Chen; Pei-Hong Wu

    2005-01-01

    AIM: To evaluate the value of CT-guided core-needle biopsy in diagnosis and classification of malignant lymphomas.METHODS: From January 1999 to October 2004, CT-guided core-needle biopsies were performed in 80 patients with suspected malignant lymphoma. Biopsies were performed with an 18-20 G biopsy-cut (CR Bard, Inc., Covington, GA,USA) needle driven by a spring-loaded Bard biopsy gun.RESULTS: A definite diagnosis and accurate histological subtype were obtained in 61 patients with a success rate of 76.25% (61/80). Surgical sampling was performed in 19 patients (23.75%) with non-diagnostic core-needle biopsies. The success rate of CT-guided core-needle biopsy varied with the histopathologic subtypes in our group.The relatively high success rates of core-needle biopsy were noted in diffuse large B-cell non-Hodgkin's lymphoma (NHL, 88.89%) and peripheral T-cell NHL (90%). However,the success rates were relatively low in anaplastic large cell (T/null cell) lymphoma (ALCL, 44.44%) and Hodgkin's disease (HD, 28.57%) in our group.CONCLUSION: CT-guided core-needle biopsy is a reliable means of diagnosing and classifying malignant lymphomas,and can be widely applied in the management of patients with suspected malignant lymphoma.

  12. Three statistical approaches to sessionizing network flow data

    OpenAIRE

    Rubin-Delanchy, Patrick T G; Lawson, Daniel John; Turcotte, Melissa J.; Heard, Nicholas A.; Adams, Niall M.

    2014-01-01

    The network traffic generated by a computer, or a pair of computers, is often well modelled as a series of sessions. These are, roughly speaking, intervals of time during which a computer is engaging in the same, continued, activity. This article explores a variety of statistical approaches to re-discovering sessions from network flow data using timing alone. Solutions to this problem are essential for network monitoring and cyber-security. For example overlapping sessions on a computer netwo...

  13. Examining Web Application by Clumping and Orienting User Session Data

    OpenAIRE

    Deenadayalan, T.; V. Kavitha; S. Rajarajeswari

    2010-01-01

    The increasing demand for reliable Web applications gives a central role to Web testing. Most of the existing works are focused on the definition of novel testing techniques, specifically tailored to the Web. However, no attempt was carried out so far to understand the specific nature of Web faults. This paper presents a user session based testing technique that clusters user sessions based on the service profile and selects a set of representative user sessions from each cluster and tailored...

  14. Summary Of Session 5: How Should We Handle Safety?

    Energy Technology Data Exchange (ETDEWEB)

    Albert, M.; Roy, G

    2001-07-01

    This session was originally titled 'Safety: Who cares?' in a fairly provocative way. A clear conclusion of this session and discussions that were held at the workshop is that there is a wide concern for safety among the people in charge of control room operations. This was shown as well by the quality of the seven talks presented in this session on subjects ranging from safety standards to a practical case of a safety incident. (author)

  15. APPLYING COLLABORATION SCRIPT IN KNOWLEDGE BASED SESSIONS

    Directory of Open Access Journals (Sweden)

    AIMAN TURANI

    2016-01-01

    Full Text Available Knowledge Based Processes, KBP, have been introduced to facilitate knowledge transfer among organizational and corporate employees. They stress on the key role of socialization and group meetings in promoting effective knowledge transfer. Meetings within virtual environment are becoming more and more used in today’s organizational settings. There are many conferencing tools that are used to facilitate such meetings. However, providing participants with a co nferencing or chatting tool and expecting them to transfer their knowledge to each other in a convenient way, could lead to many disappointments. CSCL, Computer Support for Collaborative Learning, is relatively a new discipline within teaching and learning field. Applying CSCL techniques and technologies in Knowledge Base Systems, KBS, would be a reasonable option since teaching and learning is essentially a process of knowledge transfer between instructors and students or collaboratively between students themselves. In this research we are focusing on the usage of Collaboration Script, CS, as a way to support knowledge transfer sessions in a structured and formal way. It facilitates sharing tacit knowledge via guided interpersonal interactions and turning them to explicit knowledge by capturing and retrieving these interactions. In this paper we are presenting the scripting structure of three common collaboration techniques used in Knowledge Base processes. As a proof of concept, two of these techniques are described using the collaboration scripting language, ColScript, that was introduced by us in an earlier research.

  16. Renal biopsy in the management of lupus nephritis during pregnancy.

    Science.gov (United States)

    Chen, T K; Gelber, A C; Witter, F R; Petri, M; Fine, D M

    2015-02-01

    The differential diagnosis of proteinuria and hematuria in pregnancy is broad and includes active lupus nephritis. Identification of the correct diagnosis often has a profound therapeutic impact on not only the mother but also the fetus. To date, relatively few reports exist on the role of renal biopsy during pregnancy among women with systemic lupus erythematosus (SLE). We present a case series of 11 pregnant women with SLE who underwent a renal biopsy to evaluate a presumptive flare of lupus nephritis. The electronic medical record was retrospectively analyzed for pre-biopsy serum creatinine, proteinuria, hematuria, antinuclear antibodies (ANA), and antibodies to double-stranded DNA (anti-dsDNA); histologic findings on renal biopsy; and the clinical course of each mother and fetus. From 2001 to 2012, 11 pregnant women with SLE flares during pregnancy underwent a renal biopsy at an academic tertiary medical center. At the time of biopsy, median gestational age was 16 weeks (range 9 to 27), median serum creatinine was 0.6 mg/dl (interquartile range 0.5 to 0.9), six (55%) had hematuria, and all had proteinuria >500 mg/24 hours. Proliferative lupus nephritis was found in 10 (91%) of 11 biopsies (five with ISN/RPS Class III; five with ISN/RPS Class IV). All but one individual underwent a change in management guided by information gleaned from renal biopsy. No apparent biopsy-related complications occurred to mother or fetus. Three women elected to terminate their pregnancy; although many factors were involved, the findings on renal biopsy informed the decision-making process. Among the remaining cases, there were three pre-term deliveries, one fetus with complete heart block, one in utero demise, and one maternal death. Renal biopsy is helpful at informing the management of patients with lupus nephritis during pregnancy.

  17. The clinical significance of lobular neoplasia on breast core biopsy.

    Science.gov (United States)

    Karabakhtsian, Rouzan G; Johnson, Ronald; Sumkin, Jules; Dabbs, David J

    2007-05-01

    A core biopsy diagnosis of atypical ductal epithelial hyperplasia is upstaged on follow-up excisional biopsy (FUEB) to in situ or invasive carcinoma in about 20% of cases, thus prompting a FUEB. In contrast, upstaging information for a core biopsy diagnosis of pure lobular neoplasia (LN), without mass lesions or other risk-associated lesions is less clear. In this retrospective study, we report the largest consecutive series of patients who had a breast core biopsy diagnosis of LN and a FUEB. Core needle breast biopsies with a diagnosis of LN were retrieved from our files for the period 1999 to 2005, yielding 110 patients. One hundred and one patients had a follow-up surgical excision. Cases of LN with coexisting high-risk lesions (n=9, 10%) were excluded from the study. Patients with associated mass lesions all had benign findings (n=15, 16%) and had no impact on the study results. The remaining 77 core biopsies had no masses or risk lesions and were mammographically Breast Imaging Reporting and Data System 4 (BIRADS) for microcalcifications. Overall, 8/77 (10%) of patients with a radiographic BIRADS 4 image with calcifications and a core biopsy diagnosis of LN on core biopsy were upstaged on FUEB to ductal carcinoma in situ or invasive carcinoma. The numbers upstaged from core biopsies were as follows: atypical lobular hyperplasia (ALH) 4/52 (8%), mixed ALH/lobular carcinoma in situ (LCIS) 1/9 (10%), and pure LCIS 3/16 (19%). A core biopsy of LCIS with neoplastic epithelial calcifications was nearly 3 times more likely to be upstaged on FUEB compared with ALH. We conclude that a finding of LN on breast core biopsy in a patient with a BIRADS 4 image and calcifications is associated with a risk of 8% to 19% of upstaging to a treatable disease on FUEB.

  18. An evaluation of patient experience during percutaneous breast biopsy.

    Science.gov (United States)

    Seely, Jean M; Hill, Fraser; Peddle, Susan; Lau, Jackie

    2017-05-22

    Percutaneous breast biopsy in a tertiary referral high volume breast centre: can we improve the patient experience? The study was performed to evaluate patient experience during ultrasound-guided (UGB) and vacuum-assisted stereotactic breast biopsy (SBB) and determine what factors could improve the patient experience. Consecutive patients who underwent image guided breast biopsy from 01- 05/30, 2015 were approached in a structured telephone interview to evaluate pain and bruising from the procedure. Three hundred and fifty-one patients were interviewed (116 SBB and 235 UGB). Information about the radiologist performing the biopsy, biopsy type, needle gauge, and number of cores was collected from the biopsy reports. Correlation was done using Spearman rank test. Average patient scores of pain with UGB and SBB were 2.3 and 3.1 (out of 10). There was a significant correlation between pain during SBB and physician experience (p = 0.013), and no correlation with pain during UGB (p > 0.05). No correlation was found between needle gauge and pain experienced during breast biopsy or between numbers of cores and pain (p > 0.05). Body position during SBB was mentioned to cause discomfort and pain in 28% of patients while during UGB was mentioned by 0.4% of patients. SBB was inferior to UGB for patient experience, but years of radiologists' experience correlated with improved patient scores of pain for SBB. • To achieve high quality, an institution must emphasise patient-centred care. • Increased radiologist training with stereotactic biopsy may contribute to improved patient experience. • Stereotactic breast biopsy was inferior to ultrasound biopsy for patient experience. • Radiologists' experience correlated with improved patient scores of pain for stereotactic biopsy.

  19. Ultrasound-guided transrectal extended prostate biopsy: a prospective study

    Institute of Scientific and Technical Information of China (English)

    Mohammed Ahmed Al-Ghazo; Ibrahim Fathi Ghalayini; Ismail Ibrahim Matalka

    2005-01-01

    Aim: To evaluate the diagnostic value of the 10 systematic transrectal ultrasound-guided (TRUS) prostate biopsy compared with the sextant biopsy technique for patients with suspected prostate cancer. Methods: One hundred and fifty-two patients with suspected prostate cancer were included in the study. Patients were entered in the study because they presented with high levels of prostate specific antigen (PSA) (over 4 ng/mL) and/or had undergone an abnormal digital rectal examination (DRE). In addition to sextant prostate biopsy cores, four more biopsies were obtained from the lateral peripheral zone with additional cores from each suspicious area revealed by transrectal ultrasound. Sextant, lateral peripheral zone and suspicious area biopsy cores were submitted separately to the pathological department. Results: Cancer detection rates were 27.6% (42/152) and 19.7% (30/152) for the 10-core and sextant core biopsy protocols, respectively. Adding the lateral peripheral zone (PZ) to the sextant prostate biopsy showed a 28.6% (12/42) increase in the cancer detection rate in patients with positive prostate cancer (P < 0.01).The cancer detection rate in patients who presented with elevated PSA was 29.3% (34/116). When serum PSA was 4-10 ng/mL TRUS-guided biopsy detected cancer in 20.6%, while the detection rate was 32.4% and 47.0% when serum PSA was 10-20 ng/mL and above 20 ng/mL, respectively. Conclusion: The 10 systematic TRUS-guided prostate biopsy improves the detection rate of prostate cancer by 28.6% when compared with the sextant biopsy technique alone, without increase in the morbidity. We therefore recommend the 10-core biopsy protocol to be the preferred method for early detection of prostate cancer.

  20. [Interests of advanced systematic evaluation of dialysis session].

    Science.gov (United States)

    Galland, Roula; Hallonet, Patrick; Pachot, Monique; Combe, Corinne; Schoenfelder, Isabelle; Caillette Beaudoin, Agnès

    2013-07-01

    In order to rationalize the cost of care for dialysis patients in Centre, regulatory authorities urge establishments to favor the orientation of the patients in Medical Dialysis Unit where the medical presence is not permanent. This involves clinical skills for nurses in the conduct of the dialysis session. Faced with this changing work patterns, we present two security tools of the dialysis session. The first is a "check-list", simple, quick and easy to use, it enables secure connection phase of the patient. It was quickly integrated practice of all professionals. The second tool developed is a combination of indicators "DEAUP" for Pain, Purification, Blood access, Ultrafiltration and other Problems for assessing the quality of the course of the dialysis session. The aim is to reduce the occurrence of adverse events, the DEAUP rating certain criteria depending on the occurrence of incidents, from 0 to 2, 2 corresponding to the appearance of an incident having required the call of the doctor and constitute a precious tool of evaluation of the session for all the professionals. All nurses have joined the practice of evaluation, 98% of the realized sessions are informed and quoted; 8.4% of sessions required call nephrologists before or at the connection. The evaluation at the end of dialysis session found 15% of the sessions listed 2. Calls have resulted in an adjustment to the prescription of the sessions.