WorldWideScience

Sample records for repair technician electrical

  1. Electric Vehicle Technician

    Science.gov (United States)

    Moore, Pam

    2011-01-01

    With President Obama's goal to have one million electric vehicles (EV) on the road by 2015, the electric vehicle technician should have a promising and busy future. "The job force in the car industry is ramping up for a revitalized green car industry," according to Greencareersguide.com. An electric vehicle technician will safely troubleshoot and…

  2. Diesel Engine Technician

    Science.gov (United States)

    Tech Directions, 2010

    2010-01-01

    Diesel engine technicians maintain and repair the engines that power transportation equipment such as heavy trucks, trains, buses, and locomotives. Some technicians work mainly on farm machines, ships, compressors, and pumps. Others work mostly on construction equipment such as cranes, power shovels, bulldozers, and paving machines. This article…

  3. Career Directions: HVACR Technician

    Science.gov (United States)

    Moore, Pam

    2005-01-01

    Heating/ventilation/air conditioning/refrigeration (HVACR) technicians (also known as "heating and cooling technicians") are the people who install, maintain, test and repair the machines that control temperature, circulation, moisture and purity of air in residential, commercial and industrial buildings. These systems consist of a variety of…

  4. Highlights from the Electricity Sector Council's powerline technician project

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-05-15

    The Electricity Sector Council completed a situational analysis of the powerline technician trade in Canada in April 2008. The purpose of the study was to provide industry partners with the opportunity to provide input into the development of the powerline trade; to assess the current workforce; to examine training and working conditions based on in-depth focus group interviews; and to demonstrate regional and provincial differences in apprenticeship development. This report presented highlights from the Electricity Sector Council's powerline technician project. Specifically, the report discussed the number of powerline apprentices entering the trade; regional differences in the powerline trade; and emerging practices for recruitment, retention, and training. Recommendations were also offered in order to address the challenges faced by the powerline trade. It was concluded that the best ways to recruit candidates in the powerline technician trade are to invest in a word-of mouth campaign, such as a coaching program; encourage early introduction to the trades through job sampling; offer financial incentives; and invest in outreach programs. 4 figs.

  5. You're a What?: Tower Technician

    Science.gov (United States)

    Vilorio, Dennis

    2012-01-01

    In this article, the author talks about the role and functions of a tower technician. A tower technician climbs up the face of telecommunications towers to remove, install, test, maintain, and repair a variety of equipment--from antennas to light bulbs. Tower technicians also build shelters and radiofrequency shields for electronic equipment, lay…

  6. Section 608 Technician Certification

    Science.gov (United States)

    Certifications for technicians who maintain, service, repair, or dispose of equipment that could release ozone depleting refrigerants or, after January 1, 2018, substitute refrigerants into the atmosphere.

  7. Technicians and Shop Owners

    Science.gov (United States)

    Overview page provides information for shops and technicians that repair or service motor vehicle air-conditioning systems, including information on proper training, approved equipment, and regulatory practices.

  8. 46 CFR 160.151-39 - Training of servicing technicians.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Training of servicing technicians. 160.151-39 Section...-39 Training of servicing technicians. (a) The training program for certification of servicing technicians must include— (1) Training and practice in packing an inflatable liferaft, repairing buoyancy...

  9. Quality electric motor repair: A guidebook for electric utilities

    Energy Technology Data Exchange (ETDEWEB)

    Schueler, V.; Douglass, J.

    1995-08-01

    This guidebook provides utilities with a resource for better understanding and developing their roles in relation to electric motor repair shops and the industrial and commercial utility customers that use them. The guidebook includes information and tools that utilities can use to raise the quality of electric motor repair practices in their service territories.

  10. V-TECS Guide for Automobile Air Conditioning and Electrical System Technician.

    Science.gov (United States)

    Meyer, Calvin F.; Benson, Robert T.

    This curriculum guide provides an outline for an eight-unit course to train automobile air conditioning and electrical system technicians. Each unit focuses on a duty that is composed of a number of performance objectives. For each objective, these materials are provided: a task, a standard of performance of task, source of standard, conditions…

  11. A Novel Simulation Technician Laboratory Design: Results of a Survey-Based Study.

    Science.gov (United States)

    Ahmed, Rami; Hughes, Patrick G; Friedl, Ed; Ortiz Figueroa, Fabiana; Cepeda Brito, Jose R; Frey, Jennifer; Birmingham, Lauren E; Atkinson, Steven Scott

    2016-03-16

    OBJECTIVE : The purpose of this study was to elicit feedback from simulation technicians prior to developing the first simulation technician-specific simulation laboratory in Akron, OH. Simulation technicians serve a vital role in simulation centers within hospitals/health centers around the world. The first simulation technician degree program in the US has been approved in Akron, OH. To satisfy the requirements of this program and to meet the needs of this special audience of learners, a customized simulation lab is essential. A web-based survey was circulated to simulation technicians prior to completion of the lab for the new program. The survey consisted of questions aimed at identifying structural and functional design elements of a novel simulation center for the training of simulation technicians. Quantitative methods were utilized to analyze data. Over 90% of technicians (n=65) think that a lab designed explicitly for the training of technicians is novel and beneficial. Approximately 75% of respondents think that the space provided appropriate audiovisual (AV) infrastructure and space to evaluate the ability of technicians to be independent. The respondents think that the lab needed more storage space, visualization space for a large number of students, and more space in the technical/repair area. CONCLUSIONS : A space designed for the training of simulation technicians was considered to be beneficial. This laboratory requires distinct space for technical repair, adequate bench space for the maintenance and repair of simulators, an appropriate AV infrastructure, and space to evaluate the ability of technicians to be independent.

  12. A System Approach to Navy Medical Education and Training. Appendix 15. Biotronics Technicians.

    Science.gov (United States)

    1974-08-31

    curricula based upon job analysis was implemented to a level of methodology determination. These methods and curriculum materials constituted a third...Therapy Technician 8495 Dermatology Technician 8496 Embalming Technician 8497 Medical Illustration Technician 8498 Medical Equipment Repair Technician... WET COMPRESSES/SOAKS/PACKS 24 ICONTROL BLEEDING BY PRESSURE DRESSING 25 1APPLY/CHANGE BANDAGES, E.G. ROLLER, TRIANGULAR, KURLEX GO TO RIGHT HAND PAGE

  13. Mountain Plains Learning Experience Guide: Electric Motor Repair.

    Science.gov (United States)

    Ziller, T.

    This Electric Motor Repair Course is designed to provide the student with practical information for winding, repairing, and troubleshooting alternating current and direct current motors, and controllers. The course is comprised of eight units: (1) Electric Motor Fundamentals, (2) Rewinding, (3) Split-phase Induction Motors, (4) Capacitor Motors,…

  14. Electric Motor Systems Technician: Apprenticeship Course Outline. Apprenticeship and Industry Training. 3006.2

    Science.gov (United States)

    Alberta Advanced Education and Technology, 2006

    2006-01-01

    The graduate of the Electric Motor Systems Technician apprenticeship program is a certified journeyperson who will be able to: (1) understand the principles of sound and safe trade practices; (2) interpret drawings, plans, and be able to layout and develop projects according to specifications; (3) use the tools of the trade in a safe and proper…

  15. Career Directions--Electronics Technician

    Science.gov (United States)

    Tech Directions, 2012

    2012-01-01

    Electronics technicians (ETs) work with electronics engineers to set up and maintain complicated electronics equipment that many of today's businesses rely on. The field is varied. An ET might service the industrial controls on a factory floor. Or repair missile control systems for the government. Or an ET could specialize in cars and trucks,…

  16. Section 609 Technician Training and Certification Programs

    Science.gov (United States)

    EPA-approved programs for technicians who service motor vehicle air conditioning (MVAC) systems. Any person who repairs or services a MVAC system for consideration must be certified under section 609 of the Clean Air Act by an EPA-approved program.

  17. Electrical stimulation enhances cell migration and integrative repair in the meniscus

    Science.gov (United States)

    Yuan, Xiaoning; Arkonac, Derya E.; Chao, Pen-hsiu Grace; Vunjak-Novakovic, Gordana

    2014-01-01

    Electrical signals have been applied towards the repair of articular tissues in the laboratory and clinical settings for over seventy years. We focus on healing of the meniscus, a tissue essential to knee function with limited innate repair potential, which has been largely unexplored in the context of electrical stimulation. Here we demonstrate for the first time that electrical stimulation enhances meniscus cell migration and integrative tissue repair. We optimize pulsatile direct current electrical stimulation parameters on cells at the micro-scale, and apply these to healing of full-thickness defects in explants at the macro-scale. We report increased expression of the adenosine A2b receptor in meniscus cells after stimulation at the micro- and macro-scale, and propose a role for A2bR in meniscus electrotransduction. Taken together, these findings advance our understanding of the effects of electrical signals and their mechanisms of action, and contribute to developing electrotherapeutic strategies for meniscus repair. PMID:24419206

  18. 30 CFR 77.501 - Electric distribution circuits and equipment; repair.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Electric distribution circuits and equipment... OF UNDERGROUND COAL MINES Electrical Equipment-General § 77.501 Electric distribution circuits and equipment; repair. No electrical work shall be performed on electric distribution circuits or equipment...

  19. 77 FR 2743 - Recovery Directorate Fact Sheet 9580.213, Residential Electrical Meter Repair-“Power Up”

    Science.gov (United States)

    2012-01-19

    ...] Recovery Directorate Fact Sheet 9580.213, Residential Electrical Meter Repair--``Power Up'' AGENCY: Federal..., Residential Electrical Meter Repair--``Power Up.'' DATES: Comments must be received by February 21, 2012... authority, FEMA may fund the repair of residential electrical meters damaged in a major disaster or...

  20. OPTIMUM DISTRIBUTION OF REPAIRS IN ТS-8 OF ELECTRIC LOCOMOTIVES VL80С BETWEEN REPAIR DEPOTS IN THE REPUBLIC OF KAZAKHSTAN

    Directory of Open Access Journals (Sweden)

    Seidulla ABDULLAYEV

    2017-06-01

    Full Text Available The article presents the solution for the problem of optimal distribution of electric locomotives in repair enterprises for carrying out repairs in the frame of technical service - 8 (ТS-8 and increased technical service - 8 (ITS-8. The aim of the study is to improve the efficacy of a rolling stock with a simultaneous decrease in the total expenses connected with the repair of locomotives and their transportation in repair enterprises. This is possible due to a reduction in the requirement for repairs by optimization of a resource before change of wheel bandages in electric locomotives VL80С that promotes an increase in their between-repairs run.

  1. Technician Career Opportunities in Engineering Technology.

    Science.gov (United States)

    Engineers' Council for Professional Development, New York, NY.

    Career opportunities for engineering technicians are available in the technologies relating to air conditioning, heating, and refrigeration, aviation and aerospace, building construction, chemical engineering, civil engineering, electrical engineering, electronics, industrial engineering, instrumentation, internal combustion engines, mechanical…

  2. Shuttle Repair Tools Automate Vehicle Maintenance

    Science.gov (United States)

    2013-01-01

    Successfully building, flying, and maintaining the space shuttles was an immensely complex job that required a high level of detailed, precise engineering. After each shuttle landed, it entered a maintenance, repair, and overhaul (MRO) phase. Each system was thoroughly checked and tested, and worn or damaged parts replaced, before the shuttle was rolled out for its next mission. During the MRO period, workers needed to record exactly what needed replacing and why, as well as follow precise guidelines and procedures in making their repairs. That meant traceability, and with it lots of paperwork. In 2007, the number of reports generated during electrical system repairs was getting out of hand-placing among the top three systems in terms of paperwork volume. Repair specialists at Kennedy Space Center were unhappy spending so much time at a desk and so little time actually working on the shuttle. "Engineers weren't spending their time doing technical work," says Joseph Schuh, an electrical engineer at Kennedy. "Instead, they were busy with repetitive, time-consuming processes that, while important in their own right, provided a low return on time invested." The strain of such inefficiency was bad enough that slow electrical repairs jeopardized rollout on several occasions. Knowing there had to be a way to streamline operations, Kennedy asked Martin Belson, a project manager with 30 years experience as an aerospace contractor, to co-lead a team in developing software that would reduce the effort required to document shuttle repairs. The result was System Maintenance Automated Repair Tasks (SMART) software. SMART is a tool for aggregating and applying information on every aspect of repairs, from procedures and instructions to a vehicle s troubleshooting history. Drawing on that data, SMART largely automates the processes of generating repair instructions and post-repair paperwork. In the case of the space shuttle, this meant that SMART had 30 years worth of operations

  3. Automotive Service Technician: Apprenticeship Course Outline. Apprenticeship and Industry Training. 0912

    Science.gov (United States)

    Alberta Advanced Education and Technology, 2012

    2012-01-01

    The graduate of the Automotive Service Technician apprenticeship program is a certified journeyperson who will be able to: (1) repair, maintain and overhaul or modify a motor vehicle; (2) comprehend work orders, technical bulletins and estimates, and relate the information to the job at hand; (3) interpret warranty policy in terms of service…

  4. Heavy Equipment Technician: Apprenticeship Course Outline. Apprenticeship and Industry Training. 1912

    Science.gov (United States)

    Alberta Advanced Education and Technology, 2012

    2012-01-01

    The graduate of the Heavy Equipment Technician apprenticeship program is a certified journeyperson who will be able to: (1) diagnose repair, and maintain by skills and knowledge gained through training and experience any of the working parts of diesel engines as well as the various components of mobile industrial equipment; (2) use, competently,…

  5. Agricultural Equipment Technician: Apprenticeship Course Outline. Apprenticeship and Industry Training. 3212

    Science.gov (United States)

    Alberta Advanced Education and Technology, 2012

    2012-01-01

    The graduate of the Agricultural Equipment Technician apprenticeship program is a certified journeyperson who will be able to: (1) repair, diagnose and maintain by skill and knowledge gained through training and experience any of the working parts of diesel engines as well as the various components of mobile farm machinery; (2) use, competently,…

  6. Forensic Science Technician

    Science.gov (United States)

    Tech Directions, 2010

    2010-01-01

    Forensic science technicians, also called crime laboratory technicians or police science technicians, help solve crimes. They examine and identify physical evidence to reconstruct a crime scene. This article discusses everything students need to know about careers for forensic science technicians--wages, responsibilities, skills needed, career…

  7. A Grounded Theory Study of Aircraft Maintenance Technician Decision-Making

    Science.gov (United States)

    Norcross, Robert

    Aircraft maintenance technician decision-making and actions have resulted in aircraft system errors causing aircraft incidents and accidents. Aircraft accident investigators and researchers examined the factors that influence aircraft maintenance technician errors and categorized the types of errors in an attempt to prevent similar occurrences. New aircraft technology introduced to improve aviation safety and efficiency incur failures that have no information contained in the aircraft maintenance manuals. According to the Federal Aviation Administration, aircraft maintenance technicians must use only approved aircraft maintenance documents to repair, modify, and service aircraft. This qualitative research used a grounded theory approach to explore the decision-making processes and actions taken by aircraft maintenance technicians when confronted with an aircraft problem not contained in the aircraft maintenance manuals. The target population for the research was Federal Aviation Administration licensed aircraft and power plant mechanics from across the United States. Nonprobability purposeful sampling was used to obtain aircraft maintenance technicians with the experience sought in the study problem. The sample population recruitment yielded 19 participants for eight focus group sessions to obtain opinions, perceptions, and experiences related to the study problem. All data collected was entered into the Atlas ti qualitative analysis software. The emergence of Aircraft Maintenance Technician decision-making themes regarding Aircraft Maintenance Manual content, Aircraft Maintenance Technician experience, and legal implications of not following Aircraft Maintenance Manuals surfaced. Conclusions from this study suggest Aircraft Maintenance Technician decision-making were influenced by experience, gaps in the Aircraft Maintenance Manuals, reliance on others, realizing the impact of decisions concerning aircraft airworthiness, management pressures, and legal concerns

  8. Data analyst technician: an innovative role for the pharmacy technician.

    Science.gov (United States)

    Ervin, K C; Skledar, S; Hess, M M; Ryan, M

    2001-10-01

    The development of an innovative role for the pharmacy technician is described. The role of the pharmacy technician was based on a needs assessment and the expertise of the pharmacy technician selected. Initial responsibilities of the technician included chart reviews, benchmarking surveys, monthly financial impact analysis, initiative assessment, and quality improvement reporting. As the drug-use and disease-state management (DUDSM) program expanded, pharmacist activities increased, requiring the expansion of data analyst technician (DAT) duties. These new responsibilities included participation in patient assessment, data collection and interpretation, and formulary enforcement. Most recently, technicians' expanded duties include maintenance of a physician compliance profiling database, quality improvement reporting and graphing, active role in patient risk assessment and database management for adult vaccination, and support of financial impact monitoring for other institutions within the health system. This pharmacist-technician collaboration resulted a threefold increase in patient assessments completed per day. In addition, as the DUDSM program continues to expand across the health system, an increase in DAT resources from 0.5 to 1.0 full-time equivalent was obtained. The role of the DAT has increased the efficiency of the DUDSM program and has provided an innovative role for the pharmacy technician.

  9. Transport Refrigeration Technician: Apprenticeship Course Outline. Apprenticeship and Industry Training. 4112

    Science.gov (United States)

    Alberta Advanced Education and Technology, 2012

    2012-01-01

    The graduate of the Transport Refrigeration Technician apprenticeship program is a certified journeyperson who will be able: (1) to diagnose repair, maintain and operate transport refrigeration equipment used to heat or cool the load as well as of diesel engines, APUs and other prime movers; (2) to use tools and equipment in order to carry out…

  10. Outdoor Power Equipment Technician: Apprenticeship Course Outline. Apprenticeship and Industry Training. 5111.1

    Science.gov (United States)

    Alberta Advanced Education and Technology, 2011

    2011-01-01

    The graduate of the Outdoor Power Equipment Technician apprenticeship program is a certified journeyperson who will be able to: (1) supervise, train and coach apprentices; (2) service, maintain, repair and rebuild outdoor power equipment and outdoor power equipment accessories; (3) communicate clearly with customers, staff, suppliers, as required;…

  11. Natural Gas Compression Technician: Apprenticeship Course Outline. Apprenticeship and Industry Training. 5311.1

    Science.gov (United States)

    Alberta Advanced Education and Technology, 2011

    2011-01-01

    The graduate of the Natural Gas Compression Technician apprenticeship program is a certified journeyperson who will be able to install, commission, maintain and repair equipment used to gather store and transmit natural gas. Advanced Education and Technology has prepared this course outline in partnership with the Natural Gas Compression…

  12. Design and preliminary validation of a mobile application-based expert system to facilitate repair of medical equipment in resource-limited health settings

    Directory of Open Access Journals (Sweden)

    Wong AL

    2018-05-01

    Full Text Available Alison L Wong,1,2 Kelly M Lacob,1 Madeline G Wilson,1 Stacie M Zwolski,1 Soumyadipta Acharya1 1Center for Bioengineering, Innovation and Design, Johns Hopkins University, Baltimore, MD, USA; 2Division of Plastic Surgery, Dalhousie University, Halifax, NS, Canada Background: One of the greatest barriers to safe surgery is the availability of functional biomedical equipment. Biomedical technicians play a major role in ensuring that equipment is functional. Following in-field observations and an online survey, a mobile application was developed to aid technicians in troubleshooting biomedical equipment. It was hypothesized that this application could be used to aid technicians in equipment repair, as modeled by repair of a pulse oximeter.Methods: To identify specific barriers to equipment repair and maintenance for biomedical technicians, an online survey was conducted to determine current practices and challenges. These findings were used to guide the development of a mobile application system that guides technicians through maintenance and repair tasks. A convenience sample of technicians in Ethiopia tested the application using a broken pulse oximeter task and following this completed usability and content validity surveys.Results: Fifty-three technicians from 13 countries responded to the initial survey. The results of the survey showed that technicians find equipment manuals most useful, but these are not easily accessible. Many do not know how to or are uncomfortable reaching out to human resources. Thirty-three technicians completed the broken pulse oximeter task using the application. All were able to appropriately identify and repair the equipment, and post-task surveys of usability and content validity demonstrated highly positive scores (Agree to Strongly Agree on both scales.Discussion: This research demonstrates the need for improved access to resources for technicians and shows that a mobile application can be used to address a gap in

  13. Science and engineering technicians in the United States: characteristics of a redefined population, 1972

    International Nuclear Information System (INIS)

    Finn, M.G.

    1978-02-01

    The 1972 redefined population was distributed among 10 technician fields. Approximately 75% of the total were concentrated in four relatively large fields: computer programmers; draftsmen; electrical and electronic technicians; and technicians, other fields. Women accounted for 11% of all technicians. The average age of technicians in 1972 was 37. Whites comprised 94.8% of all technicians, while 3.0% were black. More technicians resided in the middle Atlantic region than in any other region. As a percentage of the civilian labor force, however, technicians were most heavily concentrated in the New England and mountain regions. The educational level of technicians was quite diverse: about one-third had no postsecondary education, about one-sixth had at least a bachelor's degree. About one-half fell somewhere between these extremes. Approximately 68% of all technicians reported some form of supplemental training outside formal educational institutions. This training was quite diverse. In 1972, unemployed technicians totaled 3.2% of the technician labor force. Fourteen percent of technicians reported employment outside their field, and 11% reported employment outside the 10 technician fields that constituted the focus of this report. The median annual earnings of technicians employed full-time in 1971 was approximately $10,400. Private companies employed 71% of the technicians; federal and state governments employed 12.4% and 7.4%, respectively. Most other technicians were employed by local government or nonprofit organizations. Implications for policy and planning are drawn. The statistics presented here indicate that the most commonly used assumptions about education--occupation linkages are grossly oversimplified. 5 figures, 44 tables

  14. Microwave Oven Repair. Teacher Edition.

    Science.gov (United States)

    Smreker, Eugene

    This competency-based curriculum guide for teachers addresses the skills a technician will need to service microwave ovens and to provide customer relations to help retain the customer's confidence in the product and trust in the service company that performs the repair. The guide begins with a task analysis, listing 20 cognitive tasks and 5…

  15. Communication Technician: Apprenticeship Course Outline. Apprenticeship and Industry Training. 2209

    Science.gov (United States)

    Alberta Advanced Education and Technology, 2009

    2009-01-01

    The graduate of the Communication Technician apprenticeship program is a certified journeyperson who will be able to: (1) supervise, train and coach apprentices; (2) use a thorough knowledge of electrical and electronic theory and its application to communication and associated equipment used in the telecommunication industry; (3) understand…

  16. Training pharmacy technicians to administer immunizations.

    Science.gov (United States)

    McKeirnan, Kimberly C; Frazier, Kyle R; Nguyen, Maryann; MacLean, Linda Garrelts

    To evaluate the effectiveness of an immunization training program for pharmacy technicians on technicians' self-reported confidence, knowledge, and number of vaccines administered. A one-group pre- and posttest study was conducted with certified pharmacy technicians from Albertsons and Safeway community pharmacies in Idaho. Thirty pharmacy technicians were recruited to participate in an immunization administration training program comprising a 2-hour home study and a 2-hour live training. Pharmacy technician scores on a 10-question knowledge assessment, responses on a pre- and posttraining survey, and number of immunizations administered in the 6-month period following the training were collected. Twenty-five pharmacy technicians completed the home study and live portions of the immunization training program. All 29 pharmacy technicians who took the home study assessment passed with greater than 70% competency on the first attempt. Technicians self-reported increased confidence with immunization skills between the pretraining survey and the posttraining survey. From December 2016 to May 2017, the technicians administered 953 immunizations with 0 adverse events reported. For the first time, pharmacy technicians have legally administered immunizations in the United States. Trained pharmacy technicians demonstrated knowledge of vaccination procedures and self-reported improved confidence in immunization skills and administered immunizations after participating in a 4-hour training program. Copyright © 2018 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  17. Proceedings of the bright futures in Canada conference : building talent for a powerful tomorrow : powerline technician symposium

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-07-01

    This powerline technician symposium was held as part of the Electricity Sector Council (ESC) project conducted to report on emerging practices related to the recruitment, retention, and training of powerline technicians. Participants at the symposium were provided with an in-depth discussion of the ESC's situational analysis of the powerline technical trade in Canada. Electric power industry professionals from across Canada discussed regional practices related to the training and recruitment of new powerline technicians. Training programs discussed at the symposium included Cambrian College's powertechmodel; New Brunswick Power's mobile learning program; Hydro Ottawa's apprentice program; and Bright Futures BC's apprentice program. Career materials and methods of promoted the skilled labour market in Canada were also presented. The symposium featured a panel discussion as well as 4 panel PowerPoint presentations. tabs., figs.

  18. Brief electrical stimulation improves nerve regeneration after delayed repair in Sprague Dawley rats.

    Science.gov (United States)

    Elzinga, Kate; Tyreman, Neil; Ladak, Adil; Savaryn, Bohdan; Olson, Jaret; Gordon, Tessa

    2015-07-01

    Functional recovery after peripheral nerve injury and surgical repair declines with time and distance because the injured neurons without target contacts (chronic axotomy) progressively lose their regenerative capacity and chronically denervated Schwann cells (SCs) atrophy and fail to support axon regeneration. Findings that brief low frequency electrical stimulation (ES) accelerates axon outgrowth and muscle reinnervation after immediate nerve surgery in rats and human patients suggest that ES might improve regeneration after delayed nerve repair. To test this hypothesis, common peroneal (CP) neurons were chronically axotomized and/or tibial (TIB) SCs and ankle extensor muscles were chronically denervated by transection and ligation in rats. The CP and TIB nerves were cross-sutured after three months and subjected to either sham or one hour 20Hz ES. Using retrograde tracing, we found that ES significantly increased the numbers of both motor and sensory neurons that regenerated their axons after a three month period of chronic CP axotomy and/or chronic TIB SC denervation. Muscle and motor unit forces recorded to determine the numbers of neurons that reinnervated gastrocnemius muscle demonstrated that ES significantly increased the numbers of motoneurons that reinnervated chronically denervated muscles. We conclude that electrical stimulation of chronically axotomized motor and sensory neurons is effective in accelerating axon outgrowth into chronically denervated nerve stumps and improving target reinnervation after delayed nerve repair. Possible mechanisms for the efficacy of ES in promoting axon regeneration and target reinnervation after delayed nerve repair include the upregulation of neurotrophic factors. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. A new standard for multidisciplinary health and safety technicians

    International Nuclear Information System (INIS)

    Trinoskey, P.A.; Fry, L.A.; Egbert, W.F.

    2000-01-01

    Over the last two decades, a significant trend in health and safety has been toward greater specialization. However, compartmentalization of health and safety disciplines often leads to an inequity in resources, especially when appropriations overemphasize one risk to the detriment of others. For example, overemphasis on radiological safety can create an imbalance in overall worker protection. A multidisciplinary technical can help restore the balance and provide for a healthier and safer work environment. The key advantages of a multidisciplinary health and safety technician include: Broad coverage of the work area by one technician, More diverse use of the technician pool, Better coverage for off-shift or nonstandard hours, Balance of risks because all hazards are considered, Integrated emergency response, Ownership, Less time of identify the correct person with the requisite skills. We have developed a new standard that establishes the training and related qualifications for a multidisciplinary health and safety technician. The areas of training and qualification that are addressed include elements of industrial hygiene, industrial safety, fire protection, electrical safety, construction safety, and radiation safety. The initial core training program ensures that individuals are trained to the performance of requirements of the job. Initial training is in five areas: Fundamentals, Hazard recognition, Hazard assessment, Hazards controls, Hazards minimization. Core training is followed by formal qualification on specific tasks, including ventilation surveys, air monitoring, noise assessments, radiological monitoring, area inspections, work-area setups, and work coverage. The new standard addresses not only training topics and requirements, but also guidance to ensure that performance objectives are met. The standard applies to technicians, supervisors, technologists, and six specialty areas, including academic institutions and decontamination and decommissioning

  20. A new standard for multidisciplinary health and safety technicians

    Energy Technology Data Exchange (ETDEWEB)

    Trinoskey, P.A.; Fry, L.A. [Lawrence Livermore National Laboratory, Univ. of California, CA (United States); Egbert, W.F. [Lawrence Livermore National Laboratory, Allied Signal Technical Corporation (United States)

    2000-05-01

    Over the last two decades, a significant trend in health and safety has been toward greater specialization. However, compartmentalization of health and safety disciplines often leads to an inequity in resources, especially when appropriations overemphasize one risk to the detriment of others. For example, overemphasis on radiological safety can create an imbalance in overall worker protection. A multidisciplinary technical can help restore the balance and provide for a healthier and safer work environment. The key advantages of a multidisciplinary health and safety technician include: Broad coverage of the work area by one technician, More diverse use of the technician pool, Better coverage for off-shift or nonstandard hours, Balance of risks because all hazards are considered, Integrated emergency response, Ownership, Less time of identify the correct person with the requisite skills. We have developed a new standard that establishes the training and related qualifications for a multidisciplinary health and safety technician. The areas of training and qualification that are addressed include elements of industrial hygiene, industrial safety, fire protection, electrical safety, construction safety, and radiation safety. The initial core training program ensures that individuals are trained to the performance of requirements of the job. Initial training is in five areas: Fundamentals, Hazard recognition, Hazard assessment, Hazards controls, Hazards minimization. Core training is followed by formal qualification on specific tasks, including ventilation surveys, air monitoring, noise assessments, radiological monitoring, area inspections, work-area setups, and work coverage. The new standard addresses not only training topics and requirements, but also guidance to ensure that performance objectives are met. The standard applies to technicians, supervisors, technologists, and six specialty areas, including academic institutions and decontamination and decommissioning

  1. The enforcement regulation for the law for radiation technicians engaging in medical treatment

    International Nuclear Information System (INIS)

    1985-01-01

    The ordinance is set up under the provisions of the law concerning radiation and x-ray technicians engaging in medical treatment, to enforce it. An application for the license of such a technician shall be filed according to the form prescribed, attached with a copy or an abstract of the census register of the applicant and a medical certificate of a doctor concerning whether the applicant is an insane, deaf or blind person, or a case of epidemic. The membership registration of such a technician shall include the number and date of the registration, the prefecture of his legal domicile, name birth date and sex distinction, the year and month of his success in the examination for such technicains, the items concerning the cancellation of the license or the suspension of the business, etc. The subjects of the examination for such technicians are physics, radiological physics, electrical engineering, chemistry, general basic medical science, radiological biology, photographing technology, treatment technics and others. An application for the examination for such technicians shall be filed to the Minister of Health and Welfare, attached with a personal history, a study certificate or a diploma of graduation, a photograph of the applicant and other specified documents. (Kubozono, M.)

  2. Electricity for the entertainment electrician & technician

    CERN Document Server

    Cadena, Richard

    2012-01-01

    Basic Electricity for the Entertainment Electrician will reinforce the fundamentals of electricity, power distribution, safety, and show you the latest technology on things like:* IGBTs* sine-wave dimming* all of the latest software applications (list to come)In the ever-changing entertainment technology field, this book will give you enough information to prepare you for a future in the industry or reinforce the practical experience you have already gained. If you understand the principles in this book, you will

  3. The enforcement regulation for the law for radiation and x-ray technicians engaging in medical treatment

    International Nuclear Information System (INIS)

    1978-01-01

    These provisions are established on the basis of and to enforce the ''Law for radiation and X-ray technicians engaging in medical treatment''. Applications for the license of radiation and X-ray technicians engaging in medical treatment shall be filed, attached with a copy or an abstract of the census register of the applicant and a medical certificate by a doctor of whether the applicant is an insane, a deaf, a dumb or a blind person or a person caught by an infectious disease or not. In the register of such technicians, the number and the date of registration, the names of the prefectures where the technicians are legally domiciled, their names and the date of birth, the year and month of passing the examination, the matters concerning withdrawal of the license or suspension of the practice must be written. The date and the place of the examination for such technicians shall be published beforehand on the official gazette. The examinations for such radiation and X-ray technicians are made on the subjects, such as physics, electrical engineering, chemistry, elementary medical science, radiology, photographing technique, medical treatment technique and control technique. (Okada, K.)

  4. Calcium influx affects intracellular transport and membrane repair following nanosecond pulsed electric field exposure.

    Science.gov (United States)

    Thompson, Gary Lee; Roth, Caleb C; Dalzell, Danielle R; Kuipers, Marjorie; Ibey, Bennett L

    2014-05-01

    The cellular response to subtle membrane damage following exposure to nanosecond pulsed electric fields (nsPEF) is not well understood. Recent work has shown that when cells are exposed to nsPEF, ion permeable nanopores (2  nm) created by longer micro- and millisecond duration pulses. Nanoporation of the plasma membrane by nsPEF has been shown to cause a transient increase in intracellular calcium concentration within milliseconds after exposure. Our research objective is to determine the impact of nsPEF on calcium-dependent structural and repair systems in mammalian cells. Chinese hamster ovary (CHO-K1) cells were exposed in the presence and absence of calcium ions in the outside buffer to either 1 or 20, 600-ns duration electrical pulses at 16.2  kV/cm, and pore size was determined using propidium iodide and calcium green. Membrane organization was observed with morphological changes and increases in FM1-43 fluorescence. Migration of lysosomes, implicated in membrane repair, was followed using confocal microscopy of red fluorescent protein-tagged LAMP1. Microtubule structure was imaged using mEmerald-tubulin. We found that at high 600-ns PEF dosage, calcium-induced membrane restructuring and microtubule depolymerization coincide with interruption of membrane repair via lysosomal exocytosis.

  5. Can they do it? Comparing the views of pharmacists and technicians to the introduction of an advanced technician role.

    Science.gov (United States)

    Napier, Patti; Norris, Pauline; Green, James; Braund, Rhiannon

    2016-04-01

    This study aimed to investigate the opinions of pharmacists and technicians regarding the ability of New Zealand technicians to take on an advanced checking technician role. A survey was developed to investigate the opinions regarding the introduction of this new role. The questions covered are: perceived ability to take on the role, training requirements and competence. Surveys were sent to pharmacists whose contact details are available for research purposes (n = 2095) and to all pharmacies in New Zealand (both community and hospital) for the attention of technicians (n = 858). The results were analysed using IBM SPSS and thematic analysis of comments was conducted. A total of 1221 surveys were returned (pharmacists = 736 and technicians = 485). The majority of the technicians (83%) believed that 'some' technicians could work in a CT role, compared with 73% of the pharmacists. Over two-thirds (69%) of the technicians felt comfortable checking a prescription at their current level of training compared with 53% of pharmacists. Both groups' comfort increased with further specific training for the technicians. The majority of both of these groups supported the change in roles. Pharmacists were less confident that technicians could take on this role now, but were more comfortable after extra training had been completed. The technicians, however, were confident they could take on this role now but would take on extra training if needed. © 2015 Royal Pharmaceutical Society.

  6. Pharmacy technician involvement in community pharmacy medication therapy management.

    Science.gov (United States)

    Lengel, Matthew; Kuhn, Catherine H; Worley, Marcia; Wehr, Allison M; McAuley, James W

    To assess the impact of technician involvement on the completion of medication therapy management (MTM) services in a community pharmacy setting and to describe pharmacists' and technicians' perceptions of technician involvement in MTM-related tasks and their satisfaction with the technician's role in MTM. Prospective observational study. In the fall of 2015, pharmacists and selected technicians from 32 grocery store-based community pharmacies were trained to use technicians within MTM services. Completed MTM claims were evaluated at all pharmacies for 3 months before training and 3 months after training. An electronic survey, developed with the use of competencies taught in the training and relevant published literature, was distributed via e-mail to trained employees 3 months after training. The total number of completed MTM claims at the 32 pharmacy sites was higher during the posttraining time period (2687 claims) versus the pretraining period (1735 claims). Of the 182 trained participants, 112 (61.5%) completed the survey. Overall, perceived technician involvement was lower than expected. However, identifying MTM opportunities was the most commonly reported technician MTM task, with 62.5% of technicians and 47.2% of pharmacists reporting technician involvement. Nearly one-half of technicians (42.5%) and pharmacists (44.0%) agreed or strongly agreed they were satisfied with the technician's role in MTM services, and 40.0% of technicians agreed that they were more satisfied with their work in the pharmacy after involvement in MTM. Three months after initial training of technicians in MTM, participation of technicians was lower than expected. However, the technicians involved most often reported identifying MTM opportunities for pharmacists, which may be a focus for future technician trainings. In addition, technician involvement in MTM services may increase satisfaction with many aspects of work for actively involved technicians. Copyright © 2018 American

  7. Technicians for the Brazilian nuclear power programme

    International Nuclear Information System (INIS)

    Martins Pinto, C.S.; Spitalnik, J.; Meakins, E.J.; Hurley, I.

    1980-01-01

    The technician has a responsible role to fulfil in nuclear industry, acting as a bridge between the engineer and the skilled worker. Technicians must have sufficient theoretical knowledge to communicate with engineers, and a thorough understanding of technological practice; the nuclear industry demands both theory and practice of a high standard. In Brazil the essential role of the technician in industry is in general recognized. However, the lack of a nationally recognized Nuclear Technician and Nuclear Technologist qualification, as well as a desire of the best technicians to quality as engineers and, in some areas, inadequate salaries has resulted in a shortage of well-trained technicians. A first step to ensure availability of these technicians is to improve their career prospects and status through definition of appropriate career standards and salaries. Practical training by the industry can only be given in factories, plants and construction sites where nuclear work is done. It is proposed to extend apprentice training centres at three sites, to give the most promising students after two years of apprentice training two further years of instruction and practice to qualify as Nuclear Technicians. The training centres are chosen to cover the three sectors of nuclear industry where special training of technicians is important: manufacture and construction; operation and maintenance; and testing and analysis for process control and safety. (author)

  8. Electronics for technicians

    CERN Document Server

    Crane, P W

    2013-01-01

    Electronics for Technicians covers the basic fundamentals of electronics, including the operation of devices and circuits. The book is meant to help the technician to obtain numerical answers to actual circuit problems. This volume consists of seven chapters, the first of which introduces the reader to the basic rules for circuits containing resistive and reactive elements. Charge and discharge of a capacitor through a resistor is discussed, along with charge and discharge of an inductance through a resistance, application of sinusoidal voltages to simple networks, and series and parallel LCR

  9. 5 CFR 842.210 - Military reserve technicians.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 2 2010-01-01 2010-01-01 false Military reserve technicians. 842.210 Section 842.210 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE... reserve technicians. (a) A military reserve technician as defined in 5 U.S.C. 8401(30) who is separated...

  10. The optimization of electric motors repair techniques as a mean for electric energy saving; La optimizacion de las tecnicas de reparacion de motores electricos como un medio para ahorrar energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Zagal Leon, Juan Ruben [Fideicomiso para el Ahorro de Energia Electrica (FIDE), Mexico, D. F. (Mexico)

    1998-12-31

    This paper presents, in a very concise, which are the techniques to optimize the electric motors repair made by the Fideicomiso para el Ahorro de Energia Electrica (FIDE), the loss of efficiency that might exist after repairing an electric motor, as well as the procedures to perform an optimum reparation of the electric motors. Furthermore, some recommendations are given for the selection of an adequate rewinding shop to guarantee that the motor does not suffer efficiency losses after its repair. [Espanol] Este trabajo presenta, de manera muy concreta, cuales son las tecnicas para optimizar las tecnicas de reparacion de motores electricos realizado por el Fideicomiso para el Ahorro de Energia Electrica (FIDE), el nivel de perdida de eficiencia que puede existir despues de reparar un motor electrico, asi como los procedimientos para realizar una optima reparacion en motores electricos. Asimismo, se proporcionan algunas recomendaciones para seleccionar un taller de reembobinado adecuado para garantizar que el motor no sufra perdidas de eficiencia despues de su reparacion.

  11. The optimization of electric motors repair techniques as a mean for electric energy saving; La optimizacion de las tecnicas de reparacion de motores electricos como un medio para ahorrar energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Zagal Leon, Juan Ruben [Fideicomiso para el Ahorro de Energia Electrica (FIDE), Mexico, D. F. (Mexico)

    1999-12-31

    This paper presents, in a very concise, which are the techniques to optimize the electric motors repair made by the Fideicomiso para el Ahorro de Energia Electrica (FIDE), the loss of efficiency that might exist after repairing an electric motor, as well as the procedures to perform an optimum reparation of the electric motors. Furthermore, some recommendations are given for the selection of an adequate rewinding shop to guarantee that the motor does not suffer efficiency losses after its repair. [Espanol] Este trabajo presenta, de manera muy concreta, cuales son las tecnicas para optimizar las tecnicas de reparacion de motores electricos realizado por el Fideicomiso para el Ahorro de Energia Electrica (FIDE), el nivel de perdida de eficiencia que puede existir despues de reparar un motor electrico, asi como los procedimientos para realizar una optima reparacion en motores electricos. Asimismo, se proporcionan algunas recomendaciones para seleccionar un taller de reembobinado adecuado para garantizar que el motor no sufra perdidas de eficiencia despues de su reparacion.

  12. The enforcement regulation for the law for radiation and x-ray technicians engaging in medical treatment

    International Nuclear Information System (INIS)

    1980-01-01

    The ordinance is set up under the provisions of the law concerning radiation and X-ray technicians engaging in medical treatment, to enforce it. An application for the license of such a technician shall be filed according to the form prescribed, attached with a copy or an abstract of the census register of the applicant and a medical certificate of a doctor concerning whether the applicant is an insane, deaf or blind person, or a case of epidemic. The membership registration of such a technician shall include the number and date of the registration, the prefecture of his legal domicile, name, birth date and sex distinction, the year and month of his success in the examination for such technicains, the items concerning the cancellation of the license or the suspension of the business, etc. The subjects of the examination for such technicians are physics, radiological physics, electrical engineering, chemistry, general basic medical science, radiological biology, photographing technology, treatment technics and others. An application for the examination for such technicians shall be filed to the Minister of Health and Welfare, attached with a personal history, a study certificate or a diploma of graduation, a photograph of the applicant and other specified documents. (Okada, K.)

  13. 24 CFR 291.530 - Eligible firefighter/emergency medical technicians.

    Science.gov (United States)

    2010-04-01

    ... medical technicians. 291.530 Section 291.530 Housing and Urban Development Regulations Relating to Housing... medical technicians. A person qualifies as a firefighter/emergency medical technician for the purposes of... technician by a fire department or emergency medical services responder unit of the federal government, a...

  14. Training nuclear technicians in two-year, post-secondary educational programs

    International Nuclear Information System (INIS)

    Hull, D.M.; Roney, M.W.

    1975-01-01

    An available and economical supply to future manpower requirements for various types of nuclear technicians can be met by developing and/or restructuring two-year, post-secondary programs at local educational institutions. The Technical Education Research Centers program is under contract from the U.S. Office of Education to delineate the job requirements and develop curricula and instructional materials for two-year, post-secondary training of nuclear technicians. Six job categories have been identified along with corresponding tasks which the technician performs. These categories are: Reactor Operator, Nuclear Instrumentation Technician, Nuclear QA/QC Technician, Radiochemistry Technician, Radiation Protection Technician and Nuclear Medicine Technician. For the first five categories curricula have been established, courses have been described, and instructional materials are being written

  15. Knowledge and attitudes about smoking cessation among pharmacy technicians.

    Science.gov (United States)

    Zillich, Alan J; Aquilino, Mary L; Farris, Karen B

    2004-01-01

    To evaluate the knowledge and attitudes of pharmacy technicians before and after attending a continuing education program about smoking cessation. A pre/post survey of a single group. Two statewide meetings of the Iowa Pharmacy Association. Pharmacy technicians. One 2-hour continuing education (CE) course about smoking cessation for pharmacy technicians. Changes in scores before and after the CE sessions among three domains (knowledge, efficacy, and outcome) of a validated survey instrument. Fifty-one technicians completed both the presession and postsession questionnaire. For the three survey domains, technicians' knowledge (P = .034), efficacy (P < .001), and outcome (P < .001) showed significant improvement between the presession and postsession surveys (Wilcoxon signed rank test). Pharmacy technicians who attended a CE program on smoking cessation improved their knowledge, attitudes, and self-confidence in helping smokers quit. Additional research should be conducted to test the role of pharmacy technicians in smoking cessation promotion.

  16. Enactment of mandatory pharmacy technician certification in Kansas.

    Science.gov (United States)

    Lucas, Amber; Massey, Lindsay; Gill, Taylor; Burger, Gregory; Little, Jeff D

    2016-02-01

    The successful enactment of mandatory pharmacy technician certification in Kansas is described. In 2004, Kansas began requiring registration of all pharmacy technicians with the state board of pharmacy. Registration identified individuals working as pharmacy technicians but did not require any specific education or certification. In September 2012, the Kansas Board of Pharmacy created a task force of key stakeholders including pharmacists from multiple areas of practice, the University of Kansas School of Pharmacy, organizational leaders from the Kansas Council of Health-System Pharmacists (KCHP) and Kansas Pharmacists Association, and professional lobbyists. The goals of this task force were to research practices of technician certification in other states and to make recommendations to the state board of pharmacy on how Kansas could accomplish mandatory technician certification. The task force outlined the steps needed to achieve legislation that could be supported by the members. These topics included the creation of a technician trainee category, grandfathering certain technicians who had been practicing for a designated period of time, state board-approved exemptions, training requirements, age and education requirements, continuing-education requirements, and pharmacist:technician ratio. The recommendations were finalized at the August 2013 Kansas Pharmacy Summit, and the proposed legislation was introduced and passed during the 2014 legislative session. KCHP members learned many valuable lessons about advocacy and the legislative process with this initiative, including building relationships, working with legislators, and working with other professional organizations. The formation of a task force led to the successful passage of a bill granting the Kansas Board of Pharmacy the authority to issue regulations regarding mandatory pharmacy technician certification. Copyright © 2016 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  17. Improving job satisfaction and enlarging the role of technicians.

    Science.gov (United States)

    Spooner, S H; Britton, M E; Erskine, L M; Verschoor, B A; Williams, P A

    1991-01-01

    The process used in preparing this administrative report provided the means of documenting departmental support of technician task expansion, cost benefits, increased availability of professional time, and the need for a dynamic department. Some of the benefits to St. Luke's Regional Medical Center and its Pharmacy Department were an increase in technician job satisfaction, improved quality of patient care attributable to the increased scope of pharmacy service, and up to 8554 hours per year of professional time available for more clinically oriented responsibilities. If technician turnover were decreased by half, technician pricing errors eliminated, and technicians assumed the identified technical tasks, potential monetary benefits could be as much as +116,900 per year. The departmental cost of implementing these recommendations would be an additional 4.16 technician FTEs, and the professional time for training, supervising, and coordinating technicians and functions. These recommendations were well received by pharmacy administration, and the committee was asked to develop a list of priorities and an implementation plan for administrative approval.

  18. Aplastic anemia in Japanese radiological technicians

    International Nuclear Information System (INIS)

    Kitabatake, T.; Watanabe, T.; Saito, A.; Nakamura, M.; Shiohama Hospital, Mie

    1976-01-01

    Among the Japanese radiological technicians, four deaths from aplastic anemia have been reported after 1930. On the other hand, during the period from 1930 to 1960, the population of radiological technicians is estimated to be 74,400 man-years, in which 0.5 aplastic anemias are expected. However, actually three died from aplastic anemia. This difference is statistically significant at the 1% level. While, in the period from 1961 to 1973, the observed value is 1 against 0.7 expected. It is concluded that aplastic anemia had been induced frequently among the Japanese radiological technicians in the era when there was much exposure to occupational radiation. (orig.) [de

  19. Draft environmental statement related to steam generator repair at H.B. Robinson Steam Electric Plant Unit No. 2, (Docket No. 50-261)

    International Nuclear Information System (INIS)

    1983-09-01

    The staff has considered the environmental impacts and economic costs of the proposed steam generator repair at the H.B. Robinson Steam Electric Plant Unit No. 2 along with reasonable alternatives to the proposed action. The staff has concluded that the proposed repair will not significantly affect the quality of the human environment and that there are no preferable alternatives to the proposed action. Furthermore, any impacts from the repair program are outweighted by its benefits

  20. Welding Technician

    Science.gov (United States)

    Smith, Ken

    2009-01-01

    About 95% of all manufactured goods in this country are welded or joined in some way. These welded products range in nature from bicycle handlebars and skyscrapers to bridges and race cars. The author discusses what students need to know about careers for welding technicians--wages, responsibilities, skills needed, career advancement…

  1. Pneumoconiosis and respiratory problems in dental laboratory technicians: Analysis of 893 dental technicians

    Directory of Open Access Journals (Sweden)

    Dilek Ergün

    2014-10-01

    Full Text Available Objectives: To explore the rate of pneumoconiosis in dental technicians (DTP and to evaluate the risk factors. Material and Methods: Data of 893 dental technicians, who were admitted to our hospital in the period January 2007–May 2012, from 170 dental laboratories were retrospectively examined. Demographic data, respiratory symptoms, smoking status, work duration, working fields, exposure to sandblasting, physical examination findings, chest radiographs, pulmonary function tests and high-resolution computed tomography results were evaluated. Results: Dental technicians’ pneumoconiosis rate was 10.1% among 893 cases. The disease was more common among males and in those exposed to sandblasting who had 77-fold higher risk of DTP. The highest profusion subcategory was 3/+ (according to the International Labour Organization (ILO 2011 standards and the large opacity rate was 13.3%. Conclusions: To the best of our knowledge, it was the largest DTP case series (N = 893/90 in the literature in English. Health screenings should be performed regularly for the early diagnosis of pneumoconiosis, which is an important occupational disease for dental technicians.

  2. Qualification of electric motors class 1E for supply of motors and its repair

    International Nuclear Information System (INIS)

    Perez, E.; Gonzalez, J. J.; Fernandez, A.; Garcia, D.

    2005-01-01

    Different original suppliers of nuclear grade equipment have either disappeared or discontinued the manufacture of this kind equipment. Under this situation nuclear plants are experiencing difficulties when dealing with the substitution or maintenance of these equipment. Tecnatom and Cantarey have developed a new line of Class 1E qualified electric low voltage motors which can be used as an alternative to originally installed safety-related motors or for its repair and maintenance. (Author)

  3. [Role of the technician in a brachytherapy department].

    Science.gov (United States)

    Bélot-Cheval, V; Lemoine, L; Cuisinier, C; Gensse, M-C; Lasbareilles, O

    2013-04-01

    The role of the technician in a brachytherapy department is essential for the cohesion of the treatment team made up of the radiation oncologist, the physicist, and the technician. He/she collaborates in the different treatment steps such as taking care of the patients, training of the professionals and research studies in collaboration with the team. He participates in all steps of the treatment such as preparation, technician's consultation, catheters/templates and radioactives sources implant, dose distribution analysis and treatment. He looks after the management of planning, radioactive sources and chemist's equipments. He takes part in the training of the junior technician, and support doctors and physicists in different studies. The procedure writing and the presentation of professional practices are also part of the technician task. Copyright © 2013 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  4. Radiological control technician: Training program management manual

    International Nuclear Information System (INIS)

    1992-10-01

    This manual defines and describes the DOE Radiological Control Technician Core Training Program qualification and training process, material development requirements, standards and policies, and administration. The manual applies to Radiological Control Technician Training Programs at all DOE contractor sites

  5. Dealing with dirt : servicing and repairing cars.

    OpenAIRE

    Dant, Tim; Bowles, David

    2003-01-01

    This paper explores the significance of dirt in the work of technicians who service and repair private cars. Rather than being useful in understanding how dirt is dealt with, the historical and anthropological analyses of dirt are shown to be overly concerned with cultural significance and the idea that dirt is no more than ‘matter out of place’. Such accounts suppress the more common sense approach that dirt is unpleasant to human beings and is to be avoided if possible. In work such as gara...

  6. 40 CFR 745.90 - Renovator certification and dust sampling technician certification.

    Science.gov (United States)

    2010-07-01

    ... sampling technician certification. 745.90 Section 745.90 Protection of Environment ENVIRONMENTAL PROTECTION... technician certification. (a) Renovator certification and dust sampling technician certification. (1) To become a certified renovator or certified dust sampling technician, an individual must successfully...

  7. Radiological Control Technician: Standardized technician Qualification Standard

    International Nuclear Information System (INIS)

    1992-10-01

    The Qualification Standard states and defines the knowledge and skill requirements necessary for successful completion of the Radiological Control Technician Training Program. The standard is divided into three phases: Phase I concerns RCT Academic training. There are 13 lessons associated with the core academics program and 19 lessons associated with the site academics program. The staff member should sign the appropriate blocks upon successful completion of the examination for that lesson or group of lessons. In addition, facility specific lesson plans may be added to meet the knowledge requirements in the Job Performance Measures (JPM) of the practical program. Phase II concerns RCT core/site practical (JPMs) training. There are thirteen generic tasks associated with the core practical program. Both the trainer/evaluator and student should sign the appropriate block upon successful completion of the JPM. In addition, facility specific tasks may be added or generic tasks deleted based on the results of the facility job evaluation. Phase III concerns the oral examination board successful completion of the oral examination board is documented by the signature of the chairperson of the board. Upon completion of all of the standardized technician qualification requirements, final qualification is verified by the student and the manager of the Radiological Control Department and acknowledged by signatures on the qualification standard. The completed Qualification Standard shall be maintained as an official training record

  8. Practical analog electronics for technicians

    CERN Document Server

    Kimber, W A

    2013-01-01

    'Practical Analog Electronics for Technicians' not only provides an accessible introduction to electronics, but also supplies all the problems and practical activities needed to gain hands-on knowledge and experience. This emphasis on practice is surprisingly unusual in electronics texts, and has already gained Will Kimber popularity through the companion volume, 'Practical Digital Electronics for Technicians'. Written to cover the Advanced GNVQ optional unit in electronics, this book is also ideal for BTEC National, A-level electronics and City & Guilds courses. Together with 'Practical Digit

  9. Hematological findings in male x-ray technicians

    International Nuclear Information System (INIS)

    Meo, Sultan A.

    2004-01-01

    In view of the known health hazards of x-ray radiation, this study focuses on the basic hematological parameters: red blood cells (RBCs), white blood cells (WBCs) and platelets count in x-ray technicians. The aim was to identify the affect of x-ray radiation on blood cell counts in x-ray technicians. The present study was conducted in the Department of Physiology, College of Medicine, King Saud University, Riyadh, Kingdom of Saudi Arabia during the year 2002. In this study, a group of 40 apparently healthy male x-ray technicians with age ranging from 25-50-years were recruited. They were matched with another group of 40 apparently healthy control subjects in terms of age, sex and ethnic origin. Both groups met with exclusion criteria as per standard. Red blood cells, WBC and platelets count were performed by using a blood cell auto analyser. The mean value of platelet count was significantly decreased (p<0.01) in x-ray technicians when compared to controls. However, no significant difference was observed in RBC and WBC count between the groups. Radiation causes decreased platelet count. Further, studies are needed to study the long-term effects of x-ray radiation on blood cell count in x-ray technicians. (author)

  10. Electrical Stimulation Elicit Neural Stem Cells Activation:New Perspectives in CNS Repair

    Directory of Open Access Journals (Sweden)

    Ratrel eHuang

    2015-10-01

    Full Text Available Researchers are enthusiastically concerned about neural stem cell (NSC therapy in a wide array of diseases, including stroke, neurodegenerative disease, spinal cord injury (SCI and depression. Although enormous evidences have demonstrated that neurobehavioral improvement may benefit from NSC-supporting regeneration in animal models, approaches to endogenous and transplanted NSCs are blocked by hurdles of migration, proliferation, maturation and integration of NSCs. Electrical stimulation (ES may be a selective nondrug approach for mobilizing NSCs in the central nervous system (CNS. This technique is suitable for clinic application, because it is well established and its potential complications are manageable. Here, we provide a comprehensive review of the emerging positive role of different electrical cues in regulating NSC biology in vitro and in vivo, as well as biomaterial-based and chemical stimulation of NSCs. In the future, ES combined with stem cell therapy or other cues probably becomes an approach for promoting brain repair.

  11. Practical Skills in Laptop Computer Repairs for Curriculum Innovation in Technical Education Programmes in Nigeria

    Science.gov (United States)

    Chukwuedo, Samson O.; Omofonmwan, Godwin O.

    2015-01-01

    The increase in the use of laptop computer in Nigeria with their corresponding incessant breakdown calls for the preparation of competent technicians/technologists to carry out such repairs at the downtime of the appliance. This is one of the responsibilities of technology education programmes. This study therefore determined the practical skills…

  12. Comparing Burnout Across Emergency Physicians, Nurses, Technicians, and Health Information Technicians Working for the Same Organization

    OpenAIRE

    Schooley, Benjamin; Hikmet, Neset; Tarcan, Menderes; Yorgancioglu, Gamze

    2016-01-01

    Abstract Studies on the topic of burnout measure the effects of emotional exhaustion (EE), depersonalization (DP) (negative or cynical attitudes toward work), and reduced sense of personal accomplishment (PA). While the prevalence of burnout in practicing emergency medicine (EM) professionals has been studied, little is known of the prevalence and factors across physicians, nurses, technicians, and health information technicians working for the same institution. The aim of this study was to a...

  13. Preparing technicians for photonics industries and organizations

    Science.gov (United States)

    Souders, John; Hull, Dan

    2012-10-01

    U.S. photonics organizations need about 800 new photonics technicians each year. Thirty-one community and technical colleges have approximately 700 students enrolled in photonics related programs; about 275 of them complete their coursework and enter the workforce each year. A disparity exists between the demand and supply of qualified photonics technicians in the U.S. OP-TEC, the National Center for Optics and Photonics Education is a consortium of seven colleges, under the leadership of the University of Central Florida, and sponsored by NSF. OP-TEC's mission is to increase the quantity and quality of photonics technicians prepared at two-year colleges. OP-TEC maintains the National Photonics Skill Standards for Technicians, provides curriculum models, teaching materials, faculty training/professional development and planning services to strengthen existing college photonics programs and to attract and support new ones. OP-TEC is converting its text materials to E-Books to support students in technical programs. Through OP-TEC's recruitment efforts 84 additional colleges are interested in initiating new photonics programs. The OP-TEC Photonics College Network (OPCN) consists of 28 colleges that are currently providing photonics education. This fall OPCN will lead an additional national effort to further educate employed photonics technicians through on-line courses, complemented by lab experiences at nearby colleges. OP-TEC is expanding its outreach to photonics employers and colleges by regionalizing its approach to offering its services. OP-TEC is also planning to develop new curricula and instructional materials for AAS programs to prepare Precision Optics Technicians. This paper will detail OP-TEC's work with particular emphases on its materials and services.

  14. [Emergency Medical Technician profile in Spain].

    Science.gov (United States)

    Martínez-Isasi, Santiago; Rodríguez-Lorenzo, María José; Vázquez-Santamariña, David; Abella-Lorenzo, Javier; Castro Dios, Diana Josefa; Fernández García, Daniel

    2017-12-11

    The emergency medical technician plays a fundamental role and is the most important figure quantitatively in pre-hospital emergencies. The aim was to asses the socio-demographic, work-related, health characteristics and technical skills of an Emergency Medical Technician in Spain. Cross-sectional descriptive study. An ad hoc questionnaire was managed using Google Docs® that was delivered between April-June 2014 via email and social networks. A total of 705 questionnaires were collected. Statistical analysis was performed with SPSS ® 20.0 Windows version. A significance level p≤0.05 was used for all analyzes. The data analyzed show that the profile of the Emergency Medical Technician in Spain is an 39 year-old man, married or living as a couple and has a child. The average BMI is 27 kg/m2, does regular exercise, does not smoke. His seniority in the company is 10 years and has the Medium Cycle of Emergency Medical Technician. The analysis for gender shows that men have an average of 40, an average BMI of 27, 5 kg/m2 and work in an advanced life support unit; while women have an average of 36,5 years, an average BMI of 24,7 kg/m2, mainly work in Basic Life Support Unit and her seniority in the company is 6,76 years. Emergency Medical Technician profile is a overweight men, who refer to practise regular exercise, his seniority in the company is 10 years and is in possession of CMTES; differences were observed according to gender in BMI, resource where they perform their work, seniority and age.

  15. Advancing the role of the pharmacy technician: A systematic review.

    Science.gov (United States)

    Mattingly, Ashlee N; Mattingly, T Joseph

    To summarize the findings of a literature search on advancing the role of pharmacy technicians, including the types of training identified and the potential costs and benefits to both the technician and the pharmacy. A literature search of Scopus, Embase, and Medline was conducted on January 11, 2017. Original research, research reports, case studies, or association reports were included for review. Articles were considered to be relevant based on identification of an advanced pharmacy technician role or addressing additional training/education for technician functions. A standard data extraction form was used to collect study authors, article title, year published, journal title, study design, brief description of methods, primary outcome measures, advanced technician roles identified, additional education or training addressed, and additional costs and benefits identified in each article. A total of 33 articles were included for full review and data extraction. Study design varied, with 17 (52%) quantitative, 1 (3%) qualitative, 5 (15%) mixed-method, and 10 (30%) case study designs. Seventeen (52%) of the studies included were published after 2006. The mechanism of training was primarily through supervised on-the-job training, allowing technicians to assume administrative-based positions that facilitated a pharmacist-led clinical service, with either the pharmacist or the pharmacy receiving the greatest benefits. Although the literature supports technicians performing advanced roles in the pharmacy, resulting in either improved patient outcomes or opportunities for pharmacists to engage in additional clinical services, the benefits to the technician were primarily indirect, such as an increase in job satisfaction or a more desirable work schedule. If a technician is to take on additional roles that require completion of a formalized training or educational program, benefits that are more tangible may help to inspire technicians to pursue these roles. Copyright

  16. Comparing Burnout Across Emergency Physicians, Nurses, Technicians, and Health Information Technicians Working for the Same Organization.

    Science.gov (United States)

    Schooley, Benjamin; Hikmet, Neset; Tarcan, Menderes; Yorgancioglu, Gamze

    2016-03-01

    Studies on the topic of burnout measure the effects of emotional exhaustion (EE), depersonalization (DP) (negative or cynical attitudes toward work), and reduced sense of personal accomplishment (PA). While the prevalence of burnout in practicing emergency medicine (EM) professionals has been studied, little is known of the prevalence and factors across physicians, nurses, technicians, and health information technicians working for the same institution. The aim of this study was to assess burnout differences across EM professional types.The total population of 250 EM professionals at 2 public urban hospitals in Turkey were surveyed using the Maslach Burnout Inventory and basic social- and work-related demographics. Descriptive statistics, ANOVA, and additional post hoc tests were computed.Findings show that EE and DP scores were high across all occupational groups, while scores on PA were low. There was a statistically significant difference between nurses and medical technicians (P nurses and medical technicians (P Burnout can be high across occupational groups in the emergency department. Burnout is important for EM administrators to assess across human resources. Statistically significant differences across socio-demographic groups vary across occupational groups. However, differences between occupational groups may not be explained effectively by the demographic factors assessed in this or other prior studies. Rather, the factors associated with burnout are incomplete and require further institutional, cultural, and organizational analyses including differentiating between job tasks carried out by each EM job type.

  17. Safety evaluation report related to steam generator repair at H.B. Robinson Steam Electric Plant, Unit No. 2. Docket No. 50-261

    International Nuclear Information System (INIS)

    1983-11-01

    A Safety Evaluation Report was prepared for the H.B. Robinson Steam Electric Plant Unit No. 2 by the Office of Nuclear Reactor Regulation. This report considers the safety aspects of the proposed steam generator repair at H.B. Robinson Steam Electric Plant Unit No. 2. The report focuses on the occupational radiation exposure associated with the proposed repair program. It concludes that there is reasonable assurance that the health and safety on the public will not be endangered by the conduct of the proposed action, such activities will be conducted in compliance with the Commission's regulations, and the issuance of this amendment will not be inimical to the common defense and security or the health and safety of the public

  18. Electrical muscle stimulation elevates intramuscular BDNF and GDNF mRNA following peripheral nerve injury and repair in rats.

    Science.gov (United States)

    Willand, Michael P; Rosa, Elyse; Michalski, Bernadeta; Zhang, Jennifer J; Gordon, Tessa; Fahnestock, Margaret; Borschel, Gregory H

    2016-10-15

    Despite advances in surgery, patients with nerve injuries frequently have functional deficits. We previously demonstrated in a rat model that daily electrical muscle stimulation (EMS) following peripheral nerve injury and repair enhances reinnervation, detectable as early as two weeks post-injury. In this study, we explain the enhanced early reinnervation observed with electrical stimulation. In two groups of rats, the tibial nerve was transected and immediately repaired. Gastrocnemius muscles were implanted with intramuscular electrodes for sham or muscle stimulation. Muscles were stimulated daily, eliciting 600 contractions for one hour/day, repeated five days per week. Sixteen days following nerve injury, muscles were assessed for functional reinnervation by motor unit number estimation methods using electromyographic recording. In a separate cohort of rats, surgical and electrical stimulation procedures were identical but muscles and distal nerve stumps were harvested for molecular analysis. We observed that stimulated muscles had significantly higher motor unit number counts. Intramuscular levels of brain-derived and glial cell line-derived neurotrophic factor (BDNF and GDNF) mRNA were significantly upregulated in muscles that underwent daily electrical stimulation compared to those without stimulation. The corresponding levels of trophic factor mRNA within the distal stump were not different from one another, indicating that the intramuscular electrical stimulus does not modulate Schwann cell-derived trophic factor transcription. Stimulation over a three-month period maintained elevated muscle-derived GDNF but not BDNF mRNA. In conclusion, EMS elevates intramuscular trophic factor mRNA levels which may explain how EMS enhances neural regeneration following nerve injury. Copyright © 2016 IBRO. Published by Elsevier Ltd. All rights reserved.

  19. Regulation on the training-schools and institutions for radiation-technicians and x-ray technicians

    International Nuclear Information System (INIS)

    1977-01-01

    The regulation, in accordance with the Law on X-ray technicians (Law No. 227, 1951), controls and makes rules of the establishment and activities of schools and institutions for those technicians as above mentioned, with intent to secure prescribed qualifications and capabilities of said technicians. Such schools and institutions shall get the designation by relevant ministers of the government who have the power to supervise them, namely the Education Minister and the Minister for Health and Welfare (Article 2). Articles 4 and 4(2) prescribe the standards for the relevant ministers to make the designation of those schools and institutions, in relation to the school years, curriculums, teachers, equipments, etc. According to the standards, those schools and institutions may be of 3-year, 2-year on one-year course according to the required attainment level of students who enters them. The minimum requirement of the attainment is the secondary-school certificates for the 3-year course. The relevant ministers may require such reports from, and give such instructions to those schools and institutions as they consider necessary, and may revoke their designation when such a school on institution has become incompliant with above mentioned standards (Articles 6 and 7). (Matsushima, A.)

  20. Advancing technician practice: Deliberations of a regulatory board.

    Science.gov (United States)

    Adams, Alex J

    2018-01-01

    In 2016, the Idaho State Board of Pharmacy (U.S.) undertook a major rulemaking initiative to advance pharmacy practice by broadening the ability of pharmacists to delegate tasks to pharmacy technicians. The new rules of the Board thus moved the locus of control in technician scope of practice from law to pharmacist delegation. Pharmacist delegation is individualistic and takes into account the individual technician's capabilities, the pharmacist's comfort level, facility policies, and the risk mitigation strategies present at the facility, among other factors. State law limits, by contrast, are rigid and can mean that pharmacists are unable to delegate tasks that are or could otherwise be within the abilities of their technicians. The expanded technician duties are in two domains: 1) medication dispensing support (e.g., tech-check-tech, accepting verbal prescriptions, transferring prescriptions, and performing remote data entry); and 2) technical support for pharmacist clinical services (e.g., administering immunizations). This commentary reviews the evidence behind these expanded duties, as well as the key regulatory decision points for each task. The Board's rules and approach may prove useful to other states and even other governing bodies outside the U.S. as they consider similar issues. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Epidemiology of aplastic anemia in Japanese radiological technicians

    International Nuclear Information System (INIS)

    Kitabatake, Takashi; Watanabe, Tsuyoshi; Saito, Akira; Nakamura, Minoru.

    1976-01-01

    Among Japanese radiological technicians, four deaths from aplastic anemia have been recorded. Based on this fact, some epidemiological considerations are tried. During the period from 1930 to 1960, the population of radiological technicians is estimated to be 74,400 man-years, in which 0.5 aplastic anemias are expected. However actually three died from aplastic anemia. This difference is statistically significant at the 1% level. On the other hand, in the period from 1961 to 1973, the observed value is 1 against 0.7 expected. It is concluded that aplastic anemia had been frequently induced among Japanese radiological technicians in the era when there was much exposure to occupational radiation. (auth.)

  2. Defining the Simulation Technician Role: Results of a Survey-Based Study.

    Science.gov (United States)

    Bailey, Rachel; Taylor, Regina G; FitzGerald, Michael R; Kerrey, Benjamin T; LeMaster, Thomas; Geis, Gary L

    2015-10-01

    In health care simulation, simulation technicians perform multiple tasks to support various educational offerings. Technician responsibilities and the tasks that accompany them seem to vary between centers. The objectives were to identify the range and frequency of tasks that technicians perform and to determine if there is a correspondence between what technicians do and what they feel their responsibilities should be. We hypothesized that there is a core set of responsibilities and tasks for the technician position regardless of background, experience, and type of simulation center. We conducted a prospective, survey-based study of individuals currently functioning in a simulation technician role in a simulation center. This survey was designed internally and piloted within 3 academic simulation centers. Potential respondents were identified through a national mailing list, and the survey was distributed electronically during a 3-week period. A survey request was sent to 280 potential participants, 136 (49%) responded, and 73 met inclusion criteria. Five core tasks were identified as follows: equipment setup and breakdown, programming scenarios into software, operation of software during simulation, audiovisual support for courses, and on-site simulator maintenance. Independent of background before they were hired, technicians felt unprepared for their role once taking the position. Formal training was identified as a need; however, the majority of technicians felt experience over time was the main contributor toward developing knowledge and skills within their role. This study represents a first step in defining the technician role within simulation-based education and supports the need for the development of a formal job description to allow recruitment, development, and certification.

  3. Radiologic Equipment and Technicians according to the Distribution of the Population

    International Nuclear Information System (INIS)

    Yoon, Chul Ho; Choi, Jun Gu

    2009-01-01

    The purpose of this paper is to provide basic data in order to systematize the management of demand and supply of radiologic technicians, to pursue a fair regional distribution of educational institutions, and furthermore to keep reasonable medical treatment and fee. This research was carried out through the investigation of radiologic equipment and technicians according to the distribution of the population. We compared and analyzed the correlation between regional population, the number of clinics and hospitals, the number of medical imaging devices, and the number of radiologists and radiologic technicians in 5 cities without 'Gu' administrative units in 2008. 27,317 radiologic technicians have been produced since the administration of the national qualifying exam for radiologic technicians. About 18,000 radiologic technicians are currently working. There are 39 colleges or universities with Departments of Radiology and the admission quota is 2,120 students excluding one college. The ratio of radiologic equipment to radiologic technicians is 2.6 to 1. There is a dilemma in which some radiologic technicians fail to find appropriate jobs while some clinics or hospitals are in need of radiologic technicians. This dilemma is due to unreasonable regional discrepancies in pay system and welfare situation, and excessive profit-oriented recruiting system of clinics and hospitals. The increase of students of Radiologic Departments and approval of additional departments will end up with producing superfluous high academic degree holders, which is on the contrary to the government policy to produce more job opportunities. So the policy of increasing Radiologic Departments should be reconsidered.

  4. Fiber Optics Technician. Curriculum Research Project. Final Report.

    Science.gov (United States)

    Whittington, Herschel K.

    A study examined the role of technicians in the fiber optics industry and determined those elements that should be included in a comprehensive curriculum to prepare fiber optics technicians for employment in the Texas labor market. First the current literature, including the ERIC database and equipment manufacturers' journals were reviewed. After…

  5. Motorcycle Repair.

    Science.gov (United States)

    Hein, Jim; Bundy, Mike

    This motorcycle repair curriculum guide contains the following ten areas of study: brake systems, clutches, constant mesh transmissions, final drives, suspension, mechanical starting mechanisms, electrical systems, fuel systems, lubrication systems, and overhead camshafts. Each area consists of one or more units of instruction. Each instructional…

  6. Pneumoconiosis and exposures of dental laboratory technicians

    International Nuclear Information System (INIS)

    Rom, W.N.; Lockey, J.E.; Lee, J.S.; Kimball, A.C.; Bang, K.M.; Leaman, H.; Johns, R.E. Jr.; Perrota, D.; Gibbons, H.L.

    1984-01-01

    One hundred and seventy-eight dental laboratory technicians and 69 non-exposed controls participated in an epidemiological respiratory study. Eight technicians who had a mean of 28 years grinding nonprecious metal alloys were diagnosed as having a simple pneumoconiosis by chest radiograph. Mean values for per cent predicted FVC and FEV1 were reduced among male nonsmoker technicians compared to male nonsmoker controls; after controlling for age, there was also a reduction in spirometry with increasing work-years. An industrial hygiene survey was conducted in 13 laboratories randomly selected from 42 laboratories stratified by size and type of operation in the Salt Lake City, Utah metropolitan area. Personal exposures to beryllium and cobalt exceeded the Threshold Limit Values (TLVs) in one laboratory. Occupational exposures in dental laboratories need to be controlled to prevent beryllium-related lung disorders as well as simple pneumoconiosis

  7. A uniform approach for on-site training and qualification of health physics technicians

    International Nuclear Information System (INIS)

    Till, J.E.

    1977-01-01

    Estimates show that in the U.S. approx. 75% of the health physics technicians received their training through courses offered by their employer. The quality and the extent of this training vary considerably among nuclear facilities. This paper describes a uniform approach for on-site training and qualification of health physics technicians applicable to all nuclear facilities. The program consists of four levels of qualification: Health Physics Technician Trainee, Technician I, Technician II and Senior Technician. The training is divided into modules that are composed of formal lectures, practical factors, experience, and a comprehensive examination. The minimum time required from hiring of inexperienced trainees to qualification as Senior Technicians is approx. 24 months. A qualification guide lists each step a technician must complete in the training program and provides documentation which facilitates audits by internal and external groups. Although items in the program would differ between facilities, the program provides specific titles for technicians, based on their training and experience, which would be applicable throughout the nuclear industry. (author)

  8. Electrical principles 3 checkbook

    CERN Document Server

    Bird, J O

    2013-01-01

    Electrical Principles 3 Checkbook aims to introduce students to the basic electrical principles needed by technicians in electrical engineering, electronics, and telecommunications.The book first tackles circuit theorems, single-phase series A.C. circuits, and single-phase parallel A.C. circuits. Discussions focus on worked problems on parallel A.C. circuits, worked problems on series A.C. circuits, main points concerned with D.C. circuit analysis, worked problems on circuit theorems, and further problems on circuit theorems. The manuscript then examines three-phase systems and D.C. transients

  9. Guidebook on the education and training of technicians for nuclear power

    International Nuclear Information System (INIS)

    1989-01-01

    The IAEA Guidebook on the Education and Training of Technicians for Nuclear Power aims to assist Member States, especially the developing countries which are in the process of implementing, or intending to implement, a nuclear power programme, to understand and meet their requirements for qualified technicians in the most effective and efficient manner. It specifically seeks to assist policy makers and planners, as well as those designing and implementing education and training programmes. In this Guidebook, technician level occupations include those filled by technicians and higher level technicians (techniciens superieurs or technologists) and also by non-graduate engineers. The Guidebook complements the IAEA Guidebook on Manpower Development for Nuclear Power, as well as the IAEA Guidebook on the Qualification of Nuclear Power Plant Operations Personnel. The key objectives of this Guidebook are to describe: (1) the level and content of conventional education and training which a technician must have before nuclear oriented education and training can begin; (2) the level and content of nuclear oriented education and training; (3) measures to bridge the gap between the education and training acquired by technicians in the national technical schools (i.e. the level attained before upgrading) and the level of education and training qualifications needed for technicians to work in the nuclear power programme (i.e. the level attained after completion of nuclear oriented education and training). Valuable information on the national experiences of IAEA Member States in the education and training of technicians for nuclear power, as well as examples of such education and training from various Member States, are included in IAEA-TECDOC-526, which should be read in conjunction with the present text. 3 refs, 13 figs, 3 tabs

  10. Chemistry technician performance evaluation program Palo Verde Nuclear Generating Station

    International Nuclear Information System (INIS)

    Shawver, J.M.

    1992-01-01

    The Arizona Nuclear Power Project (ANPP), a three-reactor site located 50 miles west of Phoenix, Arizona, has developed and implemented a program for evaluating individual chemistry technician analytical performance on a routine basis. About 45 chemistry technicians are employed at the site, 15 at each operating unit. The technicians routinely perform trace level analyses for impurities of concern to PWRs. Each month a set of blind samples is provided by an outside vendor. The blind samples contain 16 parameters which are matrixed to approximate the PWR's primary and secondary cycles. Nine technicians receive the samples, three from each operating unit, and perform the required analyses. Acceptance criteria for successful performance on the blind parameters is based on the values found in the Institute of Nuclear Power Operations (INPO) Document 83-016, Revision 2, August 1989, Chemistry Quality Control Program. The goal of the program is to have each technician demonstrate acceptable performance on each of 16 analytical parameters. On completion of each monthly set, a summary report of all of the analytical results for the sample set is prepared. From the summary report, analytical bias can be detected, technician performance is documented, and overall laboratory performance can be evaluated. The program has been very successful at satisfying the INPO requirement that the analytical performance of each individual technician should be checked on at least a six-month frequency for all important parameters measured. This paper describes the program as implemented at the Palo Verde Nuclear Generating Station and provides a summary report and trend and bias graphs for illustrative purposes

  11. The law for radiation and x-ray technicians engaging in medical treatment

    International Nuclear Information System (INIS)

    1977-01-01

    The Law aims to define the qulifications of radiation and x-ray technicians engaging in medical treatment and to regulate so that the works are carried out properly for helping popularization and improvement of medicine and public hygiene. Persons who wish to be radiation or x-ray technicians engaging in medical treatment are required to pass the examinations for such technicians and obtain the licenes of the Minister of Health and Welfare for the former technicians and the license of a prefectural governor for the latter technicians. Mentally disordered, deaf, dumb or blind persons are excluded from licensees. Registration of such technicians, delivery of the license certificates and other related matters are provided for. The examinations are held concerning the knowledges and skills necessary for such technicians and carried out by the Minister of Health and Welfare. Persons except doctors, dentists and such technicians are prohibited to engage in the practices to apply radiation to human bodies. Restrictions on the intensity of radiation applied and the places of work are defined concerning such practices. Penal servitude of less than a year and fines less than yen 10,000 or yen 5,000 are imposed upon the violation of such prohibitions or restrictions. (Okada, K.)

  12. Robotics/Automated Systems Technicians.

    Science.gov (United States)

    Doty, Charles R.

    Major resources exist that can be used to develop or upgrade programs in community colleges and technical institutes that educate robotics/automated systems technicians. The first category of resources is Economic, Social, and Education Issues. The Office of Technology Assessment (OTA) report, "Automation and the Workplace," presents analyses of…

  13. Best possible medication history for hemodialysis patients obtained by a pharmacy technician.

    Science.gov (United States)

    Leung, Marianna; Jung, Joanne; Lau, Wynnie; Kiaii, Mercedeh; Jung, Beverly

    2009-09-01

    Outpatients undergoing hemodialysis are at high risk for adverse drug events. Limited resources make it challenging for pharmacists to routinely obtain a best possible medication history (BPMH). The primary objective was to determine whether, for patients undergoing hemodialysis, a pharmacy technician has the skills to obtain a BPMH that would allow a pharmacist to identify drug-related problems. The secondary objectives were to determine the number and types of medication discrepancies and drug-related problems identified and the time required by the technician to complete the BPMH. All patients treated in the hemodialysis unit during the study period were included, except for those who required an interpreter or were unable to participate in an in-person interview. A single technician was taught how to interview patients according to a structured format. For each patient, the technician's BMPH was verified by a pharmacist. The agreement rate between technician and pharmacists was determined, along with the number and types of discrepancies and drug-related problems identified. The technician interviewed 99 patients. Of the 1334 medication orders reviewed, the technician and pharmacists agreed on all but 15 (agreement rate 98.9%). A total of 358 medication discrepancies were noted for 93 patients (3.8 discrepancies per patient). Of these, 210 (59%) were undocumented intentional discrepancies, and 148 (41%) were unintentional discrepancies (most commonly errors of commission). Of the 135 drug-related problems identified, the majority involved dosing problems or nonadherence. The technician required an average of 17 min for each interview. An adequately trained technician was capable of interviewing patients to create a BPMH. A variety of medication discrepancies and drug-related problems were identified. Generation of a BPMH by a technician is a useful approach allowing pharmacists to identify drug-related problems.

  14. How do laboratory technicians perceive their role in tuberculosis diagnostic process: a cross-sectional study among laboratory technicians in health centers of Central Java Province, Indonesia

    Directory of Open Access Journals (Sweden)

    Widjanarko B

    2016-09-01

    Full Text Available Bagoes Widjanarko,1 Dyah Anantalia Widyastari,2 Martini Martini,3 Praba Ginandjar3 1Department of Health Education and Behavior Sciences, Faculty of Public Health, Diponegoro University, Semarang, Indonesia; 2Institute for Population and Social Research, Mahidol University, Salaya, Thailand; 3Department of Epidemiology, Faculty of Public Health, Diponegoro University, Semarang, Indonesia Purpose: Detection of acid-fast bacilli in respiratory specimens serves as an initial pulmonary tuberculosis (TB diagnosis. Laboratories are the essential and fundamental part of all health systems. This study aimed to describe how laboratory technicians perceived their own self and work. This included perceived self-efficacy, perceived role, perceived equipment availability, perceived procedures, perceived reward and job, and perceived benefit of health education, as well as level of knowledge and attitudes related to work performance of laboratory technicians.Methods: This was a cross-sectional quantitative study involving 120 laboratory technicians conducted in Central Java. Interviews and observation were conducted to measure performance and work-related variables.Results: Among 120 laboratory technicians, 43.3% showed fairly good performance. They complied with 50%–75% of all procedures, including sputum collection, laboratory tools utilization, sputum smearing, staining, smear examination, grading of results, and universal precaution practice. Perceived role, perceived self-efficacy, and knowledge of laboratory procedures were significantly correlated to performance, besides education and years of working as a laboratory technician. Perceived equipment availability was also significantly correlated to performance after the education variable was controlled.Conclusion: Most of the laboratory technicians believed that they have an important role in TB patients’ treatment and should display proper self-efficacy in performing laboratory activities. The

  15. Veterinary Technician Program Director Leadership Style and Program Success

    Science.gov (United States)

    Renda-Francis, Lori A.

    2012-01-01

    Program directors of American Veterinary Medical Association (AVMA) accredited veterinary technician programs may have little or no training in leadership. The need for program directors of AVMA-accredited veterinary technician programs to understand how leadership traits may have an impact on student success is often overlooked. The purpose of…

  16. Description and comparison of pharmacy technician training programs in the United States.

    Science.gov (United States)

    Anderson, Douglas C; Draime, Juanita A; Anderson, Timothy S

    2016-01-01

    To describe pharmacy technician training programs in the United States and to compare pharmacy technician program characteristics between programs with and without a pharmacist on faculty and between programs with different accreditation status. Descriptive, cross-sectional study. Not applicable. United States pharmacy technician programs. Not applicable. Student class size, faculty credentials, coursework components, program length, tuition rates, and admission criteria. Currently, there are more than 698 pharmacy technician programs across 1114 campuses, with complete data available for 216 programs. Programs varied widely in terms of class sizes, faculty credentials, and admission criteria. Programs with pharmacists on faculty were significantly less expensive than were those without pharmacists (P = 0.009). Accreditation had no impact on tuition prices. This is the first study of its kind to describe and characterize pharmacy technician training programs. There is relatively little control of technician training by the profession of pharmacy. The quality of these programs in terms of student outcomes is unknown, and it should be explored. Rigorous debate and discussion is needed regarding the future of pharmacy technician roles and the training required for those roles. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  17. A reliability-based maintenance technicians' workloads optimisation model with stochastic consideration

    Science.gov (United States)

    Ighravwe, D. E.; Oke, S. A.; Adebiyi, K. A.

    2016-06-01

    The growing interest in technicians' workloads research is probably associated with the recent surge in competition. This was prompted by unprecedented technological development that triggers changes in customer tastes and preferences for industrial goods. In a quest for business improvement, this worldwide intense competition in industries has stimulated theories and practical frameworks that seek to optimise performance in workplaces. In line with this drive, the present paper proposes an optimisation model which considers technicians' reliability that complements factory information obtained. The information used emerged from technicians' productivity and earned-values using the concept of multi-objective modelling approach. Since technicians are expected to carry out routine and stochastic maintenance work, we consider these workloads as constraints. The influence of training, fatigue and experiential knowledge of technicians on workload management was considered. These workloads were combined with maintenance policy in optimising reliability, productivity and earned-values using the goal programming approach. Practical datasets were utilised in studying the applicability of the proposed model in practice. It was observed that our model was able to generate information that practicing maintenance engineers can apply in making more informed decisions on technicians' management.

  18. Implementation of a laboratory for manufacture, repair and electric calibration of dosemeters based in ionization chambers utilized in radiotherapy

    International Nuclear Information System (INIS)

    Becker, P.H.B.; Peres, M.A.L.; Moreira, A.J.C.; Nette, H.P.

    1998-01-01

    Manufacturers of ionization chamber dosimeters for radiotherapy maintain only sales representatives in Brazil with no servicing capability causing difficulties to customers/users to get broken equipment back into operation. Aiming to partially solve this problem, a laboratory for maintenance, repair and electrical calibration was started in 1995 with the support of a two year IAEA Technical Assistance Project (BRA/1/031). (Author)

  19. Ask not what your technician can do for you-ask what you can do for your technician.

    Science.gov (United States)

    Ganderton, L

    2018-04-27

    Historically, the vital roles played by technicians in Higher Education have had little recognition. Job opportunities are often overlooked by those who have no working knowledge of such organisations and poorly defined career pathways mean that it may not be a first choice for well-qualified, ambitious individuals. With just over a third of all Higher Education technicians in the UK now due to retire in the next 10 to 15 years, fundamental changes are needed, both to attract large numbers of people into vacant roles and to retain current technical staff.National initiatives, founded and driven by charitable and professional bodies, are currently working to address the issues of technicians within Higher Education. Organisations have been urged to take action or face potential recruitment difficulties and skills gaps over the coming years. In light of these national campaigns, institutions across the UK are beginning to develop proper structured career pathways, provide professional development and improve recognition for the work of their technical workforce. Whilst these are encouraging signs, only time will tell if enough has been done to raise both the profile and appeal of a technical career in Higher Education.

  20. 46 CFR 115.700 - Permission for repairs and alterations.

    Science.gov (United States)

    2010-10-01

    ... replacement in kind, of electrical wiring, fuel lines, tanks, boilers and other pressure vessels, and steering... 46 Shipping 4 2010-10-01 2010-10-01 false Permission for repairs and alterations. 115.700 Section... AND CERTIFICATION Repairs and Alterations § 115.700 Permission for repairs and alterations. (a...

  1. 46 CFR 176.700 - Permission for repairs and alterations.

    Science.gov (United States)

    2010-10-01

    ... repair or replacement, other than replacement in kind, of electrical wiring, fuel lines, tanks, boilers... 46 Shipping 7 2010-10-01 2010-10-01 false Permission for repairs and alterations. 176.700 Section... (UNDER 100 GROSS TONS) INSPECTION AND CERTIFICATION Repairs and Alterations § 176.700 Permission for...

  2. Comparison of exercise blood pressure measured by technician and an automated system.

    Science.gov (United States)

    Garcia-Gregory, J A; Jackson, A S; Studeville, J; Squires, W G; Owen, C A

    1984-05-01

    We evaluated the automated system Blood Pressure Measuring System (BPMS) developed by NASA on 277 adult males who elected to have a treadmill test as part of their annual physical. The BPMS uses acoustic transduction with a computer-assisted ECG gating to detect nonsynchronous noise. The BPMS readings were compared to pressures simultaneously measured by trained technicians. For all stages of work, BPMS readings were higher for systolic and lower for diastolic than technician readings. At peak stages of work, BPMS systolic pressures were about 20 mmHg higher than technician readings. Within each 3-min workstage, BPMS readings were found to be more inconsistent than technician readings. The standard errors of measurement for BPMS were from two to three times higher than technician values. These data showed automated blood pressure readings were significantly different than technician values and subject to more random fluctuations. These findings demonstrate the need to view exercise blood pressure measured by automated systems with caution.

  3. Clinical Experience and Learning Style of Flight Nurse and Aeromedical Evacuation Technician Students.

    Science.gov (United States)

    De Jong, Marla J; Dukes, Susan F; Dufour, Karey M; Mortimer, Darcy L

    2017-01-01

    The clinical experience and preferred learning style of U.S. Air Force flight nurses and aeromedical evacuation technicians are unknown. Using a cross-sectional survey design, we gathered data regarding the clinical experience, level of comfort providing clinical care, and preferred learning style of 77 active duty (AD), Air Force Reserve (AFR), and Air National Guard (ANG) nurses enrolled in the U.S. Air Force School of Aerospace Medicine Flight Nurse course, and 121 AD, AFR, and ANG medical technicians enrolled in the Aeromedical Evacuation Technician course. Nurses and medical technicians reported 7.6 ± 5.5 and 3.9 ± 4.5 yr of experience, respectively. AD, AFR, and ANG nurses had comparable years of experience: 5.8 ± 3.2, 8.3 ± 6.6, and 7.9 ± 4.2 yr, respectively; however, AD medical technicians had more years of experience (5.6 ± 4.4 yr) than AFR (3.1 ± 4.8 yr) and ANG (1.9 ± 2.8 yr) medical technicians. Both nurses and medical technicians reported infrequently caring for patients with various disease processes and managing equipment or devices that they will routinely encounter when transporting patients as an aeromedical evacuation clinician. Nurses and medical technicians preferred a kinesthetic learning style or a multimodal learning style that included kinesthetic learning. Nearly all (99%) nurses and 97% of medical technicians identified simulation as their preferred teaching method. These findings confirm faculty concerns regarding the clinical experience of flight nurse and aerospace evacuation technician students.De Jong MJ, Dukes SF, Dufour KM, Mortimer DL. Clinical experience and learning style of flight nurse and aeromedical evacuation technician students. Aerosp Med Hum Perform. 2017; 88(1):23-29.

  4. Establishing a clinical pharmacy technician at a United States Army military treatment facility.

    Science.gov (United States)

    Evans, Jennifer L; Gladd, Ellen M; Gonzalez, Alicia C; Tranam, Salman; Larrabee, Joni M; Lipphardt, Sarah E; Chen, Tina T; Ronn, Michael D; Spain, John

    2016-01-01

    To describe the creation of a clinical pharmacy technician position within the U.S. Army and to identify the personal skills and characteristics required to meet the demands of this role. An outpatient military treatment facility located in Maryland. The clinical pharmacy technician position was designed to support clinical pharmacy services within a patient-centered medical home. Funding and a position description were established to hire a clinical pharmacy technician. Expected duties included administrative (45%), patient education (30%), and dispensing (25%). Local policy, in accordance with federal law and U.S. Army regulations, was developed to define the expanded technician responsibility to deliver patient medication education. In the initial 3 months, the clinical pharmacy technician spent 24 hours per week on clinical activities, affording an additional 10-15 hours per week for clinical pharmacists to provide patient care. Completed consults increased from 41% to 56%, and patient-pharmacist encounters increased from 240 to 290 per month. The technician, acting as a clinical pharmacist extender, also completed an average of 90 patient encounters independently each month. As a result of these improvements, the decision was made to hire a second technician. Currently, the technicians spend 28-40 hours per week on clinical activities, offsetting an average of 26 hours per week for the clinical pharmacists. A patient-centered medical home clinical pharmacy technician can reduce the administrative workload for clinical pharmacists, improve their efficiency, and enhance the use of clinical pharmacy services. Several characteristics, particularly medication knowledge, make pharmacy technicians particularly suited for this role. The results from the implementation of a clinical pharmacy technician at this military treatment facility resulted in an Army-wide expansion of the position and suggested applicability in other practice sites, particularly in federal

  5. Management competencies required in the transition from a technician to a supervisor

    Directory of Open Access Journals (Sweden)

    Sibongile R. Mahlangu (Kubheka

    2015-05-01

    Full Text Available Orientation: Technicians are frequently promoted to supervisory positions based on their technical abilities, with scant attention focused on developing management competencies. This oversight often poses significant challenges. The effective transition from technician to supervisor is important in any organisation. Research objective: The primary objective is to identify and verify the competencies that are required for a technician and a supervisory position; the secondary objective is to identify the gap that must be filled with relevant training interventions to enable technicians to make an effective transition to a supervisory position. Motivation for this study: The identification of the management competencies required for a technician who makes a career change to a supervisor position. Research method: The sequential mixed method approach was used to enable the twophase data collection process: phase one was the quantitative phase and phase two was the qualitative phase. Main findings: The overall findings confirm that there are indeed management competencies that technicians require training and development on before being promoted to a supervisory position. Implication: Organisations need to identify the key competencies for a technician and a supervisor and implement development or training interventions that are essential to successfully transition an employee from the level of a technician to the level of a supervisor. Contribution: Organisations need to implement essential development or training interventions focused on developing management competencies and put in place support interventions such as coaching, job shadowing, mentoring and networking.

  6. Job satisfaction and patient care practices of hemodialysis nurses and technicians.

    Science.gov (United States)

    Perumal, Seena; Sehgal, Ashwini R

    2003-10-01

    The quality of hemodialysis care has been the focus of intense scrutiny, yet little is known about the job satisfaction of the nurses and technicians providing this care. We identified 240 nurses and technicians from 307 randomly selected American facilities and asked them about (a) specific domains of job satisfaction, (b) overall job satisfaction, and (c) self-reported patient care practices. Fewer than half of nurses and technicians were satisfied with their pay or their opportunities for advancement. Almost all subjects were satisfied with their personal delivery of patient care, their chance to do things for others, and their job security. About three-fourths of nurses and technicians expressed overall satisfaction with their jobs. Higher job satisfaction was associated with increased attention to patient psychosocial and educational needs. We urge local and national associations of nurses and technicians to collaborate with dialysis facilities, chains, and regulatory agencies to address specific aspects of job satisfaction.

  7. How do laboratory technicians perceive their role in the tuberculosis diagnostic process? A cross-sectional study among laboratory technicians in health centers of Central Java Province, Indonesia.

    Science.gov (United States)

    Widjanarko, Bagoes; Widyastari, Dyah Anantalia; Martini, Martini; Ginandjar, Praba

    2016-01-01

    Detection of acid-fast bacilli in respiratory specimens serves as an initial pulmonary tuberculosis (TB) diagnosis. Laboratories are the essential and fundamental part of all health systems. This study aimed to describe how laboratory technicians perceived their own self and work. This included perceived self-efficacy, perceived role, perceived equipment availability, perceived procedures, perceived reward and job, and perceived benefit of health education, as well as level of knowledge and attitudes related to work performance of laboratory technicians. This was a cross-sectional quantitative study involving 120 laboratory technicians conducted in Central Java. Interviews and observation were conducted to measure performance and work-related variables. Among 120 laboratory technicians, 43.3% showed fairly good performance. They complied with 50%-75% of all procedures, including sputum collection, laboratory tools utilization, sputum smearing, staining, smear examination, grading of results, and universal precaution practice. Perceived role, perceived self-efficacy, and knowledge of laboratory procedures were significantly correlated to performance, besides education and years of working as a laboratory technician. Perceived equipment availability was also significantly correlated to performance after the education variable was controlled. Most of the laboratory technicians believed that they have an important role in TB patients' treatment and should display proper self-efficacy in performing laboratory activities. The result may serve as a basic consideration to develop a policy for enhancing motivation of laboratory technicians in order to improve the TB control program.

  8. Experience with a pharmacy technician medication history program.

    Science.gov (United States)

    Cooper, Julie B; Lilliston, Michelle; Brooks, DeAnne; Swords, Bruce

    2014-09-15

    The implementation and outcomes of a pharmacy technician medication history program are described. An interprofessional medication reconciliation team, led by a clinical pharmacist and a clinical nurse specialist, was charged with implementing a new electronic medication reconciliation system to improve compliance with medication reconciliation at discharge and capture compliance-linked reimbursement. The team recommended that the pharmacy department be allocated new pharmacy technician full-time-equivalent positions to assume ownership of the medication history process. Concurrent with the implementation of this program, a medication history standard was developed to define rules for documentation of what a patient reports he or she is actually taking. The standard requires a structured interview with the patient or caregiver and validation with outside sources as indicated to determine which medications to document in the medication history. The standard is based on four medication administration category rules: scheduled, as-needed, short-term, and discontinued medications. The medication history standard forms the core of the medication history technician training and accountability program. Pharmacy technicians are supervised by pharmacists, using a defined accountability plan based on a set of medical staff approved rules for what medications comprise a best possible medication history. Medication history accuracy and completeness rates have been consistently over 90% and rates of provider compliance with medication reconciliation rose from under 20% to 100% since program implementation. A defined medication history based on a medication history standard served as an effective foundation for a pharmacy technician medication history program, which helped improve provider compliance with discharge medication reconciliation. Copyright © 2014 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  9. Electrical stimulation of paralyzed vibrissal muscles reduces endplate reinnervation and does not promote motor recovery after facial nerve repair in rats.

    Science.gov (United States)

    Sinis, Nektarios; Horn, Frauke; Genchev, Borislav; Skouras, Emmanouil; Merkel, Daniel; Angelova, Srebrina K; Kaidoglou, Katerina; Michael, Joern; Pavlov, Stoyan; Igelmund, Peter; Schaller, Hans-Eberhard; Irintchev, Andrey; Dunlop, Sarah A; Angelov, Doychin N

    2009-10-01

    The outcome of peripheral nerve injuries requiring surgical repair is poor. Recent work has suggested that electrical stimulation (ES) of denervated muscles could be beneficial. Here we tested whether ES has a positive influence on functional recovery after injury and surgical repair of the facial nerve. Outcomes at 2 months were compared to animals receiving sham stimulation (SS). Starting on the first day after end-to-end suture (facial-facial anastomosis), electrical stimulation (square 0.1 ms pulses at 5 Hz at an ex tempore established threshold amplitude of between 3.0 and 5.0V) was delivered to the vibrissal muscles for 5 min a day, 3 times a week. Restoration of vibrissal motor performance following ES or SS was evaluated using the video-based motion analysis and correlated with the degree of collateral axonal branching at the lesion site, the number of motor endplates in the target musculature and the quality of their reinnervation, i.e. the degree of mono- versus poly-innervation. Neither protocol reduced collateral branching. ES did not improve functional outcome, but rather reduced the number of innervated motor endplates to approximately one-fifth of normal values and failed to reduce the proportion of poly-innervated motor endplates. We conclude that ES is not beneficial for recovery of whisker function after facial nerve repair in rats.

  10. A System Approach to Navy Medical Education and Training. Appendix 8 Occupational/Physical Therapy Technician.

    Science.gov (United States)

    1974-08-31

    job analysis was implemented to a level of methodology determination. These methods and curriculum materials constituted a third (instructional) sub...Technician 8494 Physical Therapy Technician 8495 Dermatology Technician 8496 Embalming Technician 8497 Medical Illustration Technician 8498 Medical...IGIVE ICE PACK TREATMENT 9 IAPPLY WET COMPRESSESISOAKSIPACKS I 10 IGIVE INFRARED TREATMENT 11 IGIVE ULTRAVIOLET TREATMENT 12 EXPLAIN UVL THERAPY

  11. Solar Technician Program Blows Hot

    Science.gov (United States)

    Ziegler, Peg Moran

    1977-01-01

    A training program for solar heating technicians was initiated at Sonoma State College's School of Environmental Studies for CETA applicants. Among the projects designed and built were a solar alternative energy center, a solar hot water system, and a solar greenhouse. (MF)

  12. Coordinating technician allocation and maintenance routing for offshore wind farms

    NARCIS (Netherlands)

    Schrotenboer, Albert H.; uit het Broek, Michiel A. J.; Jargalsaikhan, Bolor; Roodbergen, Kees Jan

    2018-01-01

    A maintenance activity at offshore wind farms requires a combination of technicians with different skills. At an operational level, it is important to fully utilize and coordinate technicians in order to increase efficiency of the short-term maintenance planning. In this paper, we investigate

  13. 14 CFR 65.80 - Certificated aviation maintenance technician school students.

    Science.gov (United States)

    2010-01-01

    ... students has made satisfactory progress at the school and is prepared to take the oral and practical tests... technician school students. 65.80 Section 65.80 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... § 65.80 Certificated aviation maintenance technician school students. Whenever an aviation maintenance...

  14. Today's oilheat technician's manual. 3. ed.

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-07-01

    This technician's manual provided a comprehensive overview of oil heating. Recommended and well-established practices for installing and maintaining oil burners, furnaces, boilers, water heaters, and heating oil tanks were presented. Building and installation codes were presented in addition to manufacturer installation instructions. The book was divided into 17 chapters: (1) introduction to oil burners, (2) heating oil and its properties, (3) oil tanks and piping, (4) fuel units and oil valves, (5) nozzles and combustion chambers, (6) draft and venting, (7) combustion, (8) basic electricity, (9) ignition systems, (10) motors, (11) primary controls, (12) limit controls and thermostats, (13) heating systems, (14) preventative maintenance tuneups, (15) service procedures, (16) energy conservation, and (17) customer service. A glossary of terms related to oil heating was included. tabs., figs.

  15. Radiological Control Technician: Phase 4, Facility practical training attachment

    International Nuclear Information System (INIS)

    1992-10-01

    At DOE sites with more than one facility, and where RCT tasks at each facility may differ, site and facility tasks should be separated. The tasks that are common to all the facilities on the site should be included in Phase II training with the core tasks. Tasks unique to a facility should be added to the training program qualification standard, as an attachment, as Phase IV training. Not all the DOE sites will include Phase IV training in their programs. Phase IV training allows each site to qualify technicians to a select facility. Since the core training for the technicians is standardized, the transfer of technicians between facilities requires that only facility tasks be taught, provided the core qualification is current

  16. Section 608 Technician Certification Test Topics

    Science.gov (United States)

    Identifies some of the topics covered on Section 608 Technician Certification tests such as ozone depletion, the Clean Air Act and Montreal Protocol, Substitute Refrigerants and oils, Refrigeration and Recovery Techniques.

  17. The Library Technician Programme in Lebanon

    Science.gov (United States)

    Rafidi, Samia

    1973-01-01

    A description of the library technician program established by the Beirut College for Women in February 1970: its curriculum, professional staff, students, and reactions produced by the program is presented. (Author/SJ)

  18. Electrical principles and technology for engineering

    CERN Document Server

    Bird, John

    1995-01-01

    The aim of this book is to introduce students to the basic electrical and electronic principles needed by technicians in fields such as electrical engineering, electronics and telecommunications. The emphasis is on the practical aspects of the subject, and the author has followed his usual successful formula, incorporating many worked examples and problems (answers supplied) into the learning process.Electrical Principles and Technology for Engineering is John Bird's core text for Further Education courses at BTEC levels N11 and N111 and Advanced GNVQ. It is also designed to provide a comprehe

  19. Dental technician pneumoconiosis mimicking pulmonary tuberculosis: a case report.

    Science.gov (United States)

    Tan, Han Loong; Faisal, Mohamed; Soo, Chun Ian; Ban, Andrea Y L; Manap, Roslina Abdul; Hassan, Tidi M

    2016-09-07

    Dental laboratory technicians are at risk of developing occupational respiratory diseases due to exposure to various potentially toxic substances in their working environment. Since 1939, few cases of silicosis among dental technician have been reported. We illustrate a 38 year-old female, who worked in a dental laboratory for 20 years, initially treated as pulmonary tuberculosis and chronic necrotising aspergillosis without much improvement. Computed tomography guided lung biopsy and bronchoscopic transbronchial lung biopsy were performed. Lung tissue biopsies showed presence of refractile dental materials within the areas of histiocyte proliferation. The diagnosis of dental technician pneumoconiosis was obtained and our patient underwent pulmonary rehabilitation. This case highlights the importance of obtaining a detailed occupational history in tuberculosis endemic area, as pulmonary tuberculosis is a great mimicker of other respiratory diseases.

  20. Nursing cooperation in endovascular aneurysm repair treatment for aortic dissection

    International Nuclear Information System (INIS)

    Xing Li; Yuan Chanjuan; Chen Rumei; Xiao Zhanqiang; Qi Youfei

    2014-01-01

    Objective: To summarize the main points of nursing cooperation in endovascular aneurysm repair treatment for aortic dissection. Methods: Preoperative psychological care and the other preparations were carefully conducted. During the operation, the patient's body was correctly placed. Active cooperation with the performance of angiography and close observation during heparinization were carried out. The proper delivery of catheter and stent to the operator was carefully done. Close observation for the patient's vital signs, the renal function and the changes of limb blood supply were made. Results: Under close cooperation of' the operators, nurses, anesthesiologists and technicians, the surgery was successfully accomplished in 35 patients. The monitoring of vital signs during the entire performance of operation was well executed. No surgical instruments delivery error's or surgery failure due to unsuitable cooperation occurred. Conclusion: Perfect preoperative preparation, strict nursing cooperation and team cooperation are the key points to ensure a successful endovascular aneurysm repair for aortic dissection. (authors)

  1. Hydraulics and pneumatics a technician's and engineer's guide

    CERN Document Server

    Parr, Andrew

    2011-01-01

    Nearly all industrial processes require objects to be moved, manipulated or subjected to some sort of force. Such movements and manipulations are frequently accomplished by means of devices driven by liquids (hydraulics) or air (pneumatics), the subject of this book. Hydraulics and Pneumatics is written by a practicing process control engineer as a guide to the successful operation of hydraulic and pneumatic systems for all engineers and technicians working with them. Keeping mathematics and theory to a minimum, this practical guide is thorough but accessible to technicians without a

  2. ASHP statement on the pharmacy technician's role in pharmacy informatics.

    Science.gov (United States)

    2014-02-01

    The American Society of Health- System Pharmacists (ASHP) believes that specially trained pharmacy technicians can assume important supportive roles in pharmacy informatics. These roles include automation and technology systems management, management of projects, training and education, policy and governance, customer service, charge integrity, and reporting. Such roles require pharmacy technicians to gain expertise in information technology (IT) systems, including knowledge of interfaces, computer management techniques, problem resolution, and database maintenance. This knowledge could be acquired through specialized training or experience in a health science or allied scientific field (e.g., health informatics). With appropriate safeguards and supervision, pharmacy technician informaticists (PTIs) will manage IT processes in health-system pharmacy services, ensuring a safe and efficient medication-use process.

  3. The electric motor handbook

    Energy Technology Data Exchange (ETDEWEB)

    Hurst, R.W.; Feltham, P. (eds.)

    2004-05-01

    This handbook outlines the important role that electric motors play in modern society. It covers the field of motor applications from various motor types to their use and repair. It also presents practical applications of electric motors and methods on motor efficiency. More than half of all electricity generated, and 75 per cent of all industrial electricity consumption is consumed by electric motors. Electrical personnel must be aware of all factors involved in electric motors in order to choose and apply the appropriate size of electric motor. These factors include efficiency, sizing and proper application. The efficient use and maximum life expectancy of electric motors depends on proper motor protection, control and maintenance. This handbook includes articles from leading experts on electric motors in modern electrical systems. The content includes: design considerations; proper electric motor sizing techniques; optimal electric motor application; electric motor protection technology; electric motor control principles; electric motor maintenance and troubleshooting; induction electric motors; electric motor bearing currents; electric motor bearing lubrication; electromagnetism; electric motor enclosures; electric motor testing; electric motor repair; DC electric motor; electric motor starters; electric motor brushes; industrial electric motors; electric motor diagrams; AC electric motors; electric motor wiring; electric motor service; electric motor rewinding; electric motor winding; diagram of electric motor wiring; electric motor kit; and, troubleshooting electric motors. A directory of motor manufacturers and suppliers was also included. refs., tabs., figs.

  4. Use of a pharmacy technician to facilitate postfracture care provided by clinical pharmacy specialists.

    Science.gov (United States)

    Irwin, Adriane N; Heilmann, Rachel M F; Gerrity, Theresa M; Kroner, Beverly A; Olson, Kari L

    2014-12-01

    The ability of a pharmacy technician to support the patient screening and documentation-related functions of a pharmacist-driven osteoporosis management service was evaluated. A two-phase prospective study was conducted within a large integrated health system to assess a pharmacy technician's performance in supporting a multisite team of clinical pharmacy specialists providing postfracture care. In phase I of the study, a specially trained pharmacy technician provided support to pharmacists at five participating medical offices, helping to identify patients requiring pharmacist intervention and, when applicable, collecting patient-specific clinical information from the electronic health record. In phase II of the study, the amount of pharmacist time saved through the use of technician support versus usual care was evaluated. The records of 127 patient cases were reviewed by the pharmacy technician during phase I of the study, and a pharmacist agreed with the technician's determination of the need for intervention in the majority of instances (92.9%). An additional 91 patient cases were reviewed by the technician in phase II of the research. With technician support, pharmacists spent less time reviewing cases subsequently determined as not requiring intervention (mean ± S.D., 5.0 ± 3.8 minutes per case compared with 5.2 ± 4.5 minutes under the usual care model; p = 0.78). In cases requiring intervention, technician support was associated with a reduction in the average pharmacist time spent on care plan development (13.5 ± 7.1 minutes versus 18.2 ± 16.6 minutes with usual care, p = 0.34). The study results suggest that a pharmacy technician can accurately determine if a patient is a candidate for pharmacist intervention and collect clinical information to facilitate care plan development. Copyright © 2014 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  5. Pharmacy technician self-efficacies: Insight to aid future education, staff development, and workforce planning.

    Science.gov (United States)

    Desselle, Shane P; Hoh, Ryan; Holmes, Erin R; Gill, Amanpreet; Zamora, Lemuel

    2017-07-15

    The roles of pharmacy technicians are increasingly prominent given pharmacy's transition to patient-centered activities and evolving scopes of practice in many U.S. states and throughout the world. The aims of this study were to assess U.S. pharmacy technicians' self-efficacies for and attitudes toward performing current and emerging roles in hospital and in community pharmacy and to identify factors related to pharmacy technician self-efficacies in these roles. A total of 5000 pharmacy technicians from 8 U.S. states were sent an electronic survey eliciting data on current involvement, self-efficacies, and attitudes for practicing in an expansive list of practice activities. The 8 states from which the sample was drawn were selected from a stratified randomized procedure using U.S. Census Bureau geographically defined regions. Pre-notification and response reminders were employed. Data were analyzed descriptively and with univariate, inferential tests, as appropriate, to determine associations with commitment, practice environment, experience level, and other variables. Of the 612 participants who responded, 494 were currently working as a technician and not enrolled in a PharmD program of study. Participants reported various activities in which they were highly engaged. Overall, attitudes toward performing most of the activities and self-efficacies were quite favorable, even for those activities in which technicians were currently less involved. There were some notable differences between technicians practicing in community versus hospital settings. Years of experience, profession commitment, and advanced employee ranking were associated with higher levels of self-efficacy, overall. This initial examination of pharmacy technician self-efficacies identified areas that along with other factors could help employers with further expanding technician practice activities and vocational institutions with considerations for education and development of these key members

  6. Respiratory Systems of Dental Technicians Negatively Affected during 5 Years of Follow-Up

    Directory of Open Access Journals (Sweden)

    Nurgül Bozkurt

    2016-08-01

    Full Text Available Background: Dental laboratory technician is one of the professions in which dust exposure is frequently experienced and therefore the health of workers has to be monitored. Aims: In this study, changes in the pulmonary functions and of pneumoconiosis frequencies among dental technicians after five years were investigated by comparing the results of two screenings carried out in 2008 and 2013. Study Design: Cohort study. Methods: In 2008 and 2013, Provincial Health Directorate carried out two different health screenings covering all of the dental technicians working in dental laboratories in Denizli. In both screenings, a questionnaire was applied, with which socio-demographic and workplace properties of the technicians were obtained. In addition, Pulmonary function tests (PFT and standard chest X-rays of the technicians were performed. The results of these two screenings were evaluated by a chest specialist, and physical examinations were performed as necessary. In 2013, technicians who had pathologies underwent computerized tomography (HRCT. In this study, the study group was composed of dental laboratory technicians that participated in both screenings (2008 and 2013 and the data obtained from the screenings were compared. The gathered data were analyzed using paired student-t and X2 tests. Results: A total of 125 dental laboratory technicians participated in the two screenings. Overall, 92% of the technicians were male and the mean age of the participants was 35. Technicians were working for 9 hours a day, 6 days a week. Total exposure time was calculated to be around 41 thousand hours. Approximately 60% of workers were smokers. When the results of PFT were analyzed, 73% of the first evaluations were found to be normal; however, this ratio decreased to 51% in the second analysis five years later. In the second PFT measurement, compared to the first, there was a 23% decrease in the forced vital capacity (FVC value, and a 15.7% decrease in

  7. Magnox Electric Littlebrook reactor inspection and repair rehearsal facility

    International Nuclear Information System (INIS)

    Barnes, S.A.; Clayton, R.; Gaydon, B.G.; Ramsey, B.H.

    1996-01-01

    Magnox reactors, although designed to be maintenance free during their operational life, have nevertheless highlighted the need for test rig facilities to train operators in the methods and techniques of reactor inspection and repair. The history of the facility for reactor engineering development (FRED) is described and its present role as a repair rehearsal facility noted. Advances in computer graphics may, in future, mean that such operator training will be virtual reality rather than analog reality based; however the need for such rigs to commission techniques and equipment and to establish performance and reliability is likely to continue. (UK)

  8. Patient- and Technician-Oriented Attitudes Toward Transcranial Magnetic Stimulation Devices.

    Science.gov (United States)

    Lonergan, Brady; Nguyen, Eliza; Lembo, Cara; Hinchman, Carrie; Morales, Oscar G; Press, Daniel Z; Pascual-Leone, Alvaro; Stern, Adam P

    2018-01-25

    Four transcranial magnetic stimulation (TMS) devices are currently approved for use in treatment-resistant depression. The authors present the first data-driven study examining the patient- and technician-experience using three of these distinct devices. A retrospective survey design with both patient and technician arms was utilized. The study population included patients who received TMS for treatment-resistant depression at the Berenson Allen Center for Noninvasive Brain Stimulation for the first time between 2013 and 2016 and technicians who worked in the program from 2009 to 2017. Statistical analysis included t tests and analyses of variance to assess differences between and across the multiple groups, respectively. Patients treated with the NeuroStar device reported greater confidence that the treatment was being performed correctly compared with those treated with the Magstim device. Conversely, with regard to tolerability, patients treated with the Magstim device reported less pain in the last week and less pain on average compared with those treated with the NeuroStar device. On average, technicians reported feeling that both the Magstim and NeuroStar devices were significantly easier to use than the Brainsway Deep TMS H-Coil device. Additionally, they found the former two devices to be more reliable and better tolerated. Furthermore, the technicians reported greater confidence in the Magstim and NeuroStar devices compared with the Brainsway Deep TMS H-Coil device and indicated that they would be more likely to recommend the two former devices to other treatment centers.

  9. Pharmacy technician-to-pharmacist ratios: a state-driven safety and quality decision.

    Science.gov (United States)

    Bess, D Todd; Carter, Jason; DeLoach, Lindsey; White, Carol L

    2014-01-01

    To discuss the policy of pharmacy technician-to-pharmacist ratios by comparing Florida as an example of legislative-led authority versus Tennessee as an example of board of pharmacy-led ruling. Over the past 2 years, the Florida legislature has debated the issue of pharmacy staffing ratios, initially leaving the Florida Board of Pharmacy with little authority to advocate for and enact safe technician staffing ratios. Anticipating this situation, the Tennessee Board of Pharmacy created rules to meet pharmacy staffing needs while protecting the authority of the pharmacist-in-charge and promoting patient safety. Before enacting rules, members of the board toured the state and talked about proposed rule changes with pharmacists. The final rule sets the pharmacy technician-to-pharmacist ratio at 2:1 but permits a 4:1 ratio based on public safety considerations and availability of at least two Certified Pharmacy Technicians. Pharmacists and leaders within the profession should conduct further research on appropriate and safe ratios of pharmacy technicians to pharmacists, with a focus on safety and quality of care.

  10. New Zealand dental technicians and continuing education: findings from a qualitative survey.

    Science.gov (United States)

    Anderson, Vivienne R; Pang, Lilian C Y; Aarts, John M

    2012-06-01

    Under the 2003 Health Practitioners Competence Assurance (HPCA) Act, New Zealand registered dental technicians are subject to mandatory Continuing Professional Development (CPD) requirements. Internationally, little published literature has examined dental technicians' perspectives of CPD and CPD needs, and there is no published literature relating to the New Zealand context. Available research highlights the importance of CPD for maintaining high professional standards, ensuring patient safety, allowing dental technicians to keep abreast of current research and technological advances, fostering peer networks, and promoting job satisfaction. In 2009, an online open-ended questionnaire was developed to examine New Zealand dental and clinical dental technicians' perspectives of CPD and their perceived CPD needs. In total, 45 New Zealand registered dental technicians responded. Questionnaire responses provided rich qualitative insights into dental technicians' wide-ranging perceptions of CPD, factors that make CPD involvement more or less difficult and more or less desirable, and ways in which CPD access and relevance might be improved. This paper discusses the survey findings in the light of the existing literature on CPD and in relation to the unique New Zealand regulatory environment. It highlights the factors which respondents identified as shaping their CPD decisions, barriers to CPD engagement, perceived CPD needs, suggestions as to how the current CPD system could be improved, and areas for future research.

  11. Intraoperative monitoring technician: a new member of the surgical team.

    Science.gov (United States)

    Brown, Molly S; Brown, Debra S

    2011-02-01

    As surgery needs have increased, the traditional surgical team has expanded to include personnel from radiology and perfusion services. A new surgical team member, the intraoperative monitoring technician, is needed to perform intraoperative monitoring during procedures that carry a higher risk of central and peripheral nerve injury. Including the intraoperative monitoring technician on the surgical team can create challenges, including surgical delays and anesthesia care considerations. When the surgical team members, including the surgeon, anesthesia care provider, and circulating nurse, understand and facilitate this new staff member's responsibilities, the technician is able to perform monitoring functions that promote the smooth flow of the surgical procedure and positive patient outcomes. Copyright © 2011 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  12. 5 CFR 831.306 - Service as a National Guard technician before January 1, 1969.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 2 2010-01-01 2010-01-01 false Service as a National Guard technician... National Guard technician before January 1, 1969. (a) Definitions. In this section—(1) Service as a National Guard technician is service performed under section 709 of title 32, United States Code (or under...

  13. Training and qualification of health and safety technicians at a national laboratory

    International Nuclear Information System (INIS)

    Egbert, W.F.; Trinoskey, P.A.

    1994-10-01

    Over the last 30 years, Lawrence Livermore National Laboratory (LLNL) has successfully implemented the concept of a multi-disciplined technician. LLNL Health and Safety Technicians have responsibilities in industrial hygiene, industrial safety, health physics, as well as fire, explosive, and criticality safety. One of the major benefits to this approach is the cost-effective use of workers who display an ownership of health and safety issues which is sometimes lacking when responsibilities are divided. Although LLNL has always promoted the concept of a multi-discipline technician, this concept is gaining interest within the Department of Energy (DOE) community. In November 1992, individuals from Oak Ridge Institute of Science and Education (ORISE) and RUST Geotech, joined by LLNL established a committee to address the issues of Health and Safety Technicians. In 1993, the DOE Office of Environmental, Safety and Health, in response to the Defense Nuclear Facility Safety Board Recommendation 91-6, stated DOE projects, particularly environmental restoration, typically present hazards other than radiation such as chemicals, explosives, complex construction activities, etc., which require additional expertise by Radiological Control Technicians. They followed with a commitment that a training guide would be issued. The trend in the last two decades has been toward greater specialization in the areas of health and safety. In contrast, the LLNL has moved toward a generalist approach integrating the once separate functions of the industrial hygiene and health physics technician into one function

  14. Technicians under the Microscope: The Training and Skills of University Laboratory and Engineering Workshop Technicians

    Science.gov (United States)

    Lewis, Paul A.; Gospel, Howard

    2015-01-01

    The UK government aims to increase both the number, and also the status, of workers with intermediate-level skills, with a view to creating a "modern class of technicians" who can help to bolster economic growth and prosperity. This article considers the prospects for such a policy by focusing on one particular, but neglected, group of…

  15. Technician Consistency in Specular Microscopy Measurements: A "Real-World" Retrospective Analysis of a United States Eye Bank.

    Science.gov (United States)

    Rand, Gabriel M; Kwon, Ji Won; Gore, Patrick K; McCartney, Mitchell D; Chuck, Roy S

    2017-10-01

    To quantify consistency of endothelial cell density (ECD) measurements among technicians in a single US eye bank operating under typical operating conditions. In this retrospective analysis of 51 microscopy technicians using a semiautomated counting method on 35,067 eyes from July 2007 to May 2015, technician- and date-related marginal ECD effects were calculated using linear regression models. ECD variance was correlated with the number of specular microscopy technicians. Technician mean ECDs ranged from 2386 ± 431 to 3005 ± 560 cells/mm. Nine technicians had statistically and clinically significant marginal effects. Annual mean ECDs adjusted for changes in technicians ranged from 2422 ± 433 to 2644 ± 430 cells/mm. The period of 2007 to 2009 had statistically and clinically significant marginal effects. There was a nonstatistically significant association between the number of technicians and ECD standard deviation. There was significant ECD variability associated with specular microscopy technicians and with the date of measurement. We recommend that eye banks collect data related to laboratory factors that have been shown to influence ECD variability.

  16. Pharmacist and Technician Perceptions of Tech-Check-Tech in Community Pharmacy Practice Settings.

    Science.gov (United States)

    Frost, Timothy P; Adams, Alex J

    2018-04-01

    Tech-check-tech (TCT) is a practice model in which pharmacy technicians with advanced training can perform final verification of prescriptions that have been previously reviewed for appropriateness by a pharmacist. Few states have adopted TCT in part because of the common view that this model is controversial among members of the profession. This article aims to summarize the existing research on pharmacist and technician perceptions of community pharmacy-based TCT. A literature review was conducted using MEDLINE (January 1990 to August 2016) and Google Scholar (January 1990 to August 2016) using the terms "tech* and check," "tech-check-tech," "checking technician," and "accuracy checking tech*." Of the 7 studies identified we found general agreement among both pharmacists and technicians that TCT in community pharmacy settings can be safely performed. This agreement persisted in studies of theoretical TCT models and in studies assessing participants in actual community-based TCT models. Pharmacists who had previously worked with a checking technician were generally more favorable toward TCT. Both pharmacists and technicians in community pharmacy settings generally perceived TCT to be safe, in both theoretical surveys and in surveys following actual TCT demonstration projects. These perceptions of safety align well with the actual outcomes achieved from community pharmacy TCT studies.

  17. Component-Level Electronic-Assembly Repair (CLEAR) Spacecraft Circuit Diagnostics by Analog and Complex Signature Analysis

    Science.gov (United States)

    Oeftering, Richard C.; Wade, Raymond P.; Izadnegahdar, Alain

    2011-01-01

    The Component-Level Electronic-Assembly Repair (CLEAR) project at the NASA Glenn Research Center is aimed at developing technologies that will enable space-flight crews to perform in situ component-level repair of electronics on Moon and Mars outposts, where there is no existing infrastructure for logistics spares. These technologies must provide effective repair capabilities yet meet the payload and operational constraints of space facilities. Effective repair depends on a diagnostic capability that is versatile but easy to use by crew members that have limited training in electronics. CLEAR studied two techniques that involve extensive precharacterization of "known good" circuits to produce graphical signatures that provide an easy-to-use comparison method to quickly identify faulty components. Analog Signature Analysis (ASA) allows relatively rapid diagnostics of complex electronics by technicians with limited experience. Because of frequency limits and the growing dependence on broadband technologies, ASA must be augmented with other capabilities. To meet this challenge while preserving ease of use, CLEAR proposed an alternative called Complex Signature Analysis (CSA). Tests of ASA and CSA were used to compare capabilities and to determine if the techniques provided an overlapping or complementary capability. The results showed that the methods are complementary.

  18. Clinical support role for a pharmacy technician within a primary care resource center.

    Science.gov (United States)

    Fera, Toni; Kanel, Keith T; Bolinger, Meghan L; Fink, Amber E; Iheasirim, Serah

    2018-02-01

    The creation of a clinical support role for a pharmacy technician within a primary care resource center is described. In the Primary Care Resource Center (PCRC) Project, hospital-based care transition coordination hubs staffed by nurses and pharmacist teams were created in 6 independent community hospitals. At the largest site, patient volume for targeted diseases challenged the ability of the PCRC pharmacist to provide expected elements of care to targeted patients. Creation of a new pharmacy technician clinical support role was implemented as a cost-effective option to increase the pharmacist's efficiency. The pharmacist's work processes were reviewed and technical functions identified that could be assigned to a specially trained pharmacy technician under the direction of the PCRC pharmacist. Daily tasks performed by the pharmacy technician included maintenance of the patient roster and pending discharges, retrieval and documentation of pertinent laboratory and diagnostic test information from the patient's medical record, assembly of patient medication education materials, and identification of discrepancies between disparate systems' medication records. In the 6 months after establishing the PCRC pharmacy technician role, the pharmacist's completion of comprehensive medication reviews (CMRs) for target patients increased by 40.5% ( p = 0.0223), driven largely by a 42.4% ( p technician to augment pharmacist care in a PCRC team extended the reach of the pharmacist and allowed more time for the pharmacist to engage patients. Technician support enabled the pharmacist to complete more CMRs and reduced the time required for chart reviews. Copyright © 2018 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  19. Expanded pharmacy technician roles: Accepting verbal prescriptions and communicating prescription transfers.

    Science.gov (United States)

    Frost, Timothy P; Adams, Alex J

    2017-11-01

    As the role of the clinical pharmacist continues to develop and advance, it is critical to ensure pharmacists can operate in a practice environment and workflow that supports the full deployment of their clinical skills. When pharmacy technician roles are optimized, patient safety can be enhanced and pharmacists may dedicate more time to advanced clinical services. Currently, 17 states allow technicians to accept verbal prescriptions called in by a prescriber or prescriber's agent, or transfer a prescription order from one pharmacy to another. States that allow these activities generally put few legal limitations on them, and instead defer to the professional judgment of the supervising pharmacist whether to delegate these tasks or not. These activities were more likely to be seen in states that require technicians to be registered and certified, and in states that have accountability mechanisms (e.g., discipline authority) in place for technicians. There is little evidence to suggest these tasks cannot be performed safely and accurately by appropriately trained technicians, and the track record of success with these tasks spans four decades in some states. Pharmacists can adopt strong practice policies and procedures to mitigate the risk of harm from verbal orders, such as instituting read-back/spell-back techniques, or requiring the indication for each phoned-in medication, among other strategies. Pharmacists may also exercise discretion in deciding to whom to delegate these tasks. As the legal environment becomes more permissive, we foresee investment in more robust education and training of technicians to cover these activities. Thus, with the adoption of robust practice policies and procedures, delegation of verbal orders and prescription transfers can be safe and effective, remove undue stress on pharmacists, and potentially free up pharmacist time for higher-order clinical care. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Medical Laboratory Technician--Microbiology (AFSC 90470).

    Science.gov (United States)

    Thompson, Joselyn H.

    This four-volume student text is designed for use by Air Force personnel enrolled in a self-study extension course for medical laboratory technicians. Covered in the individual volumes are laboratory procedures in clinical bacteriology (the history of bacteriology; aseptic techniques and sterilization procedures; bacterial morphology and…

  1. Training needs analysis for engineering technicians in Oman

    Science.gov (United States)

    Al-Mughairi, Abdulkarim Sultan

    This thesis examines the transition from the Omani Colleges of Technology (CT) to employment of its engineering graduates. It arises out of concerns that the transition to the labour market for engineering graduate is problematical. The research was carried out to identify the knowledge, skills, and abilities (KSA) of engineering technicians required in the Omani market place. The aim is to provide local curriculum designers in the Colleges of Technology with sufficient information about the required KSA in order to create and enhance the engineering curriculum so that it has greater capacity to meet the needs of a variety of stakeholders and of employers in particular. This in turn has the potential to bridge the gap between what is presently taught and what the workplace demands. Personnel psychologists identify views concerning the skills that are required for different jobs. One of these is based on the assumption that quite different skills are required in different jobs (SCANS, 1990). This view generates approaches within job analysis: the worker-oriented and the task-oriented approaches. This research uses Position Analysis Questionnaire (PAQ), which is a worker-oriented job analysis instrument, to investigate the KSA required to perform some of the engineering technician jobs in Omani industries. In addition, semi-structured interviews were used to investigate the factors that either hinder or entirely prevent the new graduates from Colleges of Technology from being accepted in the workforce pool. The major research findings concern the dimensions of knowledge, skills, and abilities of six engineering technician job titles and the major factors that hinder or (prevent) the technical college graduates from being accepted in the market place in Oman. These findings would definitely help design better transition route and bridge the gap between the CT technicians engineering programmes and the workplace demands.

  2. THE ROLE OF SCHOOL TECHNICIANS IN PROMOTING SCIENCE THROUGH PRACTICAL WORK

    Directory of Open Access Journals (Sweden)

    Anne T. Helliar

    2011-11-01

    Full Text Available This is a review of the role of practical work in UK’s secondary school science lessons, the impact that practical work has in the promotion of science, the challenges created through use of non-specialist science teachers and a possible additional role for science technicians. The paper considers how improved deployment of suitably experienced school science technicians and their recognition, by schools’ management, for their involvement in the delivery of training in the use of practical work, for less experienced teachers, could benefit schools and their students. This together with its companion paper endeavours to show how the more effective use of practical work and technicians can encourage more students to select science at higher, non-compulsory levels.

  3. Metabolic syndrome and occupation: Any association? Prevalence among auto technicians and school teachers in South West Nigeria.

    Science.gov (United States)

    Akintunde, Adeseye A; Oloyede, Taiwo W

    2017-11-01

    To determine occupational association with metabolic syndrome among auto technicians and school teachers. One hundred and sixty six subjects were selected for this study. Clinical data was obtained while laboratory investigations including plasma glucose and lipid profile were performed. Statistical analysis was done with SPSS 20.0. Pauto technicians. Mean serum triglycerides was significantly higher among auto-technicians compared to school teachers in this study. The prevalence of some conventional cardiovascular risk factors was significantly higher among auto-technicians compared to school teachers: Impaired blood glucose (9.6% vs. 1.2%, pauto-technicians. Based on the WHO and the Harmonized criteria, metabolic syndrome was more frequent among auto-technicians compared to school teachers. (8.4% vs. 1.2% and 19.3% vs. 7.2% respectively, pauto technicians despite their high level of physical activity, exertion and education compared to teachers. This may be related to the increased occupational exposure to organic and inorganic materials from dust particles, oil and oil related matter and particulate matter among auto technicians. Prompt definitive evaluation of this concept and appropriate health education to encourage safety mechanism can reduce this burden of metabolic syndrome among auto technicians in Nigeria. Copyright © 2016 Diabetes India. Published by Elsevier Ltd. All rights reserved.

  4. Survey on the use of CAD-CAM technology by UK and Irish dental technicians.

    Science.gov (United States)

    Blackwell, E; Nesbit, M; Petridis, H

    2017-05-12

    Statement of the problem Digital workflows (CAD/CAM) have been introduced in dentistry during recent years. No published information exists on dental technicians' use and reporting of this technology.Purpose The aim of this cross sectional survey was to identify the extent digital technology has infiltrated the workplace and to investigate the factors affecting the use of CAD-CAM technology by dental laboratory technicians within Ireland and the UK.Materials and methods A web-based questionnaire was composed (Opinio, Object Planet Inc. Oslo, Norway) and distributed to UK and Irish dental technicians. Answers to all questions were anonymous and grouped such that general information was gathered initially, followed by branching of the survey into two sections depending on whether or not the respondent worked with CAD-CAM technology. Results were compiled and statistical analysis (Fisher's Exact test, SPSS, IBM, Armonk, New York, USA) was performed in order to investigate any correlation between various demographic variables and the answers provided.Results The survey was distributed to 760 UK technicians and 77 Irish technicians. The total number of completed surveys was 105, which yielded a total response rate of 14%. Most technicians reported using some form of CAD/CAM aspect in the workflow, and this was more significant for technicians working in large laboratories. Most training received was company-led. Large laboratories were also significantly correlated with less outsourcing of CAD/CAM work and a change in dental material use leading to the increase of zirconia and the decrease of noble alloys. Dental technicians did not report any significant change in working relationships and staffing as a result of CAD/CAM incorporation. High initial investment cost was the most common reason quoted from non-users, along with the lack of such technology in their working environment.

  5. Recovery Act: Training Program Development for Commercial Building Equipment Technicians

    Energy Technology Data Exchange (ETDEWEB)

    Leah Glameyer

    2012-07-12

    The overall goal of this project has been to develop curricula, certification requirements, and accreditation standards for training on energy efficient practices and technologies for commercial building technicians. These training products will advance industry expertise towards net-zero energy commercial building goals and will result in a substantial reduction in energy use. The ultimate objective is to develop a workforce that can bring existing commercial buildings up to their energy performance potential and ensure that new commercial buildings do not fall below their expected optimal level of performance. Commercial building equipment technicians participating in this training program will learn how to best operate commercial buildings to ensure they reach their expected energy performance level. The training is a combination of classroom, online and on-site lessons. The Texas Engineering Extension Service (TEEX) developed curricula using subject matter and adult learning experts to ensure the training meets certification requirements and accreditation standards for training these technicians. The training targets a specific climate zone to meets the needs, specialized expertise, and perspectives of the commercial building equipment technicians in that zone. The combination of efficient operations and advanced design will improve the internal built environment of a commercial building by increasing comfort and safety, while reducing energy use and environmental impact. Properly trained technicians will ensure equipment operates at design specifications. A second impact is a more highly trained workforce that is better equipped to obtain employment. Organizations that contributed to the development of the training program include TEEX and the Texas Engineering Experiment Station (TEES) (both members of The Texas A&M University System). TEES is also a member of the Building Commissioning Association. This report includes a description of the project

  6. Internet treatment for depression: a randomized controlled trial comparing clinician vs. technician assistance.

    Science.gov (United States)

    Titov, Nickolai; Andrews, Gavin; Davies, Matthew; McIntyre, Karen; Robinson, Emma; Solley, Karen

    2010-06-08

    Internet-based cognitive behavioural therapy (iCBT) for depression is effective when guided by a clinician, less so if unguided. Would guidance from a technician be as effective as guidance from a clinician? Randomized controlled non-inferiority trial comparing three groups: Clinician-assisted vs. technician-assisted vs. delayed treatment. Community-based volunteers applied to the VirtualClinic (www.virtualclinic.org.au) research program, and 141 participants with major depressive disorder were randomized. Participants in the clinician- and technician-assisted groups received access to an iCBT program for depression comprising 6 online lessons, weekly homework assignments, and weekly supportive contact over a treatment period of 8 weeks. Participants in the clinician-assisted group also received access to a moderated online discussion forum. The main outcome measures were the Beck Depression Inventory (BDI-II) and the Patient Health QUESTIONnaire-9 Item (PHQ-9). Completion rates were high, and at post-treatment, both treatment groups reduced scores on the BDI-II (ptechnician-assisted groups respectively, and on the PHQ-9, were 1.54 and 1.60 respectively. At 4-month follow-up participants in the technician group had made further improvements and had significantly lower scores on the PHQ-9 than those in the clinician group. A total of approximately 60 minutes of clinician or technician time was required per participant during the 8-week treatment program. Both clinician- and technician-assisted treatment resulted in large effect sizes and clinically significant improvements comparable to those associated with face-to-face treatment, while a delayed treatment control group did not improve. These results provide support for large scale trials to determine the clinical effectiveness and acceptability of technician-assisted iCBT programs for depression. This form of treatment has potential to increase the capacity of existing mental health services. Australian New

  7. An in-depth examination into pharmacy technician worklife through an organizational behavior framework.

    Science.gov (United States)

    Desselle, Shane P

    2016-01-01

    Pharmacy technicians are a vital part of the health care workforce. Little is known about perceptions of their own work environment that would engender more effective recruitment, retention, and management strategies by pharmacists and employers. The purpose of this study was to gain a greater understanding of certified pharmacy technician worklife. Specific objectives included the identification of themes of worklife phenomena to assist with the development of appropriate responses by other pharmacy stakeholders and to ascertain the contribution of various factors engendering or discouraging career commitment of pharmacy technicians. Semi-structured in-depth interviews were carried out with a convenience sample of pharmacy technicians in one U.S. state, who varied by their work settings and level of experience. The interview guide and corresponding participant responses were framed from around an organizational cultural basis rooted in organizational behavior theory. Notes from the interviews were analyzed thematically using directed content analysis. Four primary themes emerged, including: career impetus, job responsibilities, quality of work life, and equitable partnership. The data revealed pharmacy technicians' need for self-actualization and recognition of the value they bring to the organization. The participants identified primary responsibilities that contribute to their sense of worth and those that if not managed adequately potentially detract from their well-being and effectiveness. Findings in regard to rate of pay corroborate previous work on wages as both an intrinsic and extrinsic motivator. Pharmacy technicians seek equity among each other (their peers) and in a mutually beneficial relationship with their employing organization. This study provides the impetus for interventions and further study that should serve to enhance pharmacy technician effectiveness, quality of work life, and longevity in an emerging profession. Copyright © 2015 Elsevier

  8. A longitudinal study on lung disease in dental technicians: What has changed after seven years?

    Directory of Open Access Journals (Sweden)

    Derya Özdemir Dogan

    2013-10-01

    Full Text Available Objectives: The aim of this 7-year follow-up study was to determine respiratory changes in dental technicians. Material and Methods: In our region, in the year 2005, 36 dental technicians were evaluated with a cross-sectional study on respiratory occupational diseases, and in 2012 we evaluated them again. Inclusion of information on respiratory symptoms and demographic features questionnaires was applied. Pulmonary function tests (PFT were performed. Chest X-rays (CXR were evaluated according to the ILO-2000 classification. For the comparisons of the technicians' findings in 2005 and 2012, data analyses were performed with the Wilcoxon test in addition to descriptive statistical procedures. Results: In 2012, 19 out of the 36 technicians continued to work in the same place, so we were able to evaluate their findings. The prevalence of respiratory symptoms in dental technician was as follows: dyspnea 7 (37%, cough 6 (32%, and phlegm 5 (26%. According to ILO classifications in 2005, among the 36 technicians, 5 (13.8% had pneumoconiosis. At the end of 7 years, there were 9 pneumoconiosis cases among the 19 remaining technicians (47%. Thus, there was a statistically significant progression on the profusion of the radiologic findings (p < 0.005. Also there was a significant worsening on spirometric findings (p < 0.05. Conclusion: In dental technicians, a determination of both radiologic and functional progressions at the end of 7 years demonstrate that the primary and secondary preventive measures are necessary for these workplaces. Workplaces must be regularly controlled for worker health and hygiene.

  9. [Competencies in the education of nursing technicians to implement the nursing care systematization].

    Science.gov (United States)

    da Cruz, Andrea de Mello Pereira; Almeida, Miriam de Abreu

    2010-12-01

    This is a qualitative, exploratory and descriptive study whose general objective was to learn, considering the perspective of the nursing technician who works in school hospitals, the competencies developed during their educational process to implement the Nursing Care Systematization (NCS). Data collection and analysis were carried out through a focal group, with content analysis and nursing technicians. Two thematic categories emerged: The participation of the nursing technician in the NCS and The competencies in the education of the nursing technician. Each one received two subcategories: Conception of the NCS and (De)valuation of the NCS, Technical-scientific competency and Competency in the interpersonal relationship, respectively. It was observed that the NCS must be shared, discussed and made public among nursing professionals, so that they may acknowledge themselves as the leading actors of their methodology and be aware that their practices determine the results.

  10. DNA damage and cytotoxicity in pathology laboratory technicians exposed to organic solvents

    Directory of Open Access Journals (Sweden)

    TATIANE DE AQUINO

    2016-03-01

    Full Text Available The aim of this study was to evaluate potential DNA damage and cytotoxicity in pathology laboratory technicians exposed to organic solvents, mainly xylene. Peripheral blood and buccal cells samples were collected from 18 technicians occupationally exposed to organic solvents and 11 non-exposed individuals. The technicians were sampled at two moments: Monday and Friday. DNA damage and cytotoxicity were evaluated using the Comet Assay and the Buccal Micronucleus Cytome assay. Fifteen subjects (83.5% of the exposed group to solvents complained about some symptom probably related to contact with vapours of organic solvents. DNA damage in the exposed group to solvents was nearly 2-fold higher on Friday than on Monday, and in both moments the individuals of this group showed higher levels of DNA damage in relation to controls. No statistical difference was detected in buccal cell micronucleus frequency between the laboratory technicians and the control group. However, in the analysis performed on Friday, technicians presented higher frequency (about 3-fold of karyolytic and apoptotic-like cells (karyorrhectic and pyknotic in relation to control group. Considering the damage frequency and the working time, a positive correlation was found in the exposed group to solvents (r=0.468; p=0.05. The results suggest that pathology laboratory workers inappropriately exposed to organic solvents have increased levels of DNA damage.

  11. Partnership for electrical generation technology education

    International Nuclear Information System (INIS)

    Rasmussen, R. S.; Beaty, L.; Holman, R.

    2006-01-01

    This Engineering Technician education effort adapts an existing two-year Instrumentation and Control (I and C) education program into a model that is focused on electrical-generation technologies. It will also locally implement a program developed elsewhere with National Science Foundation funding, aimed at public schools, and adapt it to stimulate pre-college interest in pursuing energy careers in general. (authors)

  12. Changing Roles of Librarians and Library Technicians

    Directory of Open Access Journals (Sweden)

    Norene James

    2015-10-01

    Full Text Available What significant changes are librarians and library technicians experiencing in their roles? A survey put forward across Canada to librarians and library technicians addressing this question was conducted in February 2014. Eight hundred eighty-two responses were obtained from librarians, defined as MLIS graduates, and library technicians, defined as graduates from a two-year library diploma program. Respondents needed to have been employed in the last two years in these roles and students of either an MLIS or LIT program were also welcome to participate. The results suggest that both librarians and library technicians perceive their roles as growing in scope and complexity and that the lines of responsibility are blurring. A majority of respondents indicated that they perceive a change in their roles in the past five years and commented on what the perceived changes were. Librarian and library technician roles may be shifting away from what may be viewed as traditional or clearly defined responsibilities and both librarians and library technicians may be taking on new tasks as well as experiencing task overlap. All library staff will need to be fluid, adaptable, and open to change. Library school curricula and workplace training need to incorporate the development of these competencies. Quels sont les changements importants éprouvés par les bibliothécaires et les bibliotechniciens dans leurs rôles? Un sondage mené en février de 2014 a posé cette question aux bibliothécaires et aux bibliotechniciens dans tout le Canada. On a reçu huit-cent quatre-vingt-deux réponses des bibliothécaires, définis comme étant diplômés en MSIB, et les bibliotechniciens, définis comme étant diplômés d’un programme de deux ans en bibliotechnique. Les sondés devaient avoir travaillé au cours des deux dernières années dans ces fonctions et les étudiants d’un programme MSIB ou de bibliothéconomie/ sciences de l’information pouvaient aussi y

  13. AeroVironment technician checks a Helios solar cell panel

    Science.gov (United States)

    2000-01-01

    A technician at AeroVironment's Design Development Center in Simi Valley, California, checks a panel of silicon solar cells for conductivity and voltage. The bi-facial cells, fabricated by SunPower, Inc., of Sunnyvale, California, are among 64,000 solar cells which have been installed on the Helios Prototype solar-powered aircraft to provide power to its 14 electric motors and operating systems. Developed by AeroVironment under NASA's Environmental Research Aircraft and Sensor Technology (ERAST) project, the Helios Prototype is the forerunner of a planned fleet of slow-flying, long duration, high-altitude aircraft which can perform atmospheric science missions and serve as telecommunications relay platforms in the stratosphere. Target goals set by NASA for the giant 246-foot span flying wing include reaching and sustaining subsonic horizontal flight at 100,000 feet altitude in 2001, and sustained continuous flight for at least four days and nights above 50,000 feet altitude with the aid of a regenerative fuel cell-based energy storage system now under development in 2003.

  14. Defining the Role of the Pharmacy Technician and Identifying Their Future Role in Medicines Optimisation.

    Science.gov (United States)

    Boughen, Melanie; Sutton, Jane; Fenn, Tess; Wright, David

    2017-07-15

    Traditionally, pharmacy technicians have worked alongside pharmacists in community and hospital pharmacy. Changes within pharmacy provide opportunity for role expansion and with no apparent career pathway, there is a need to define the current pharmacy technician role and role in medicines optimisation. To capture the current roles of pharmacy technicians and identify how their future role will contribute to medicines optimisation. Following ethical approval and piloting, an online survey to ascertain pharmacy technicians' views about their roles was undertaken. Recruitment took place in collaboration with the Association of Pharmacy Technicians UK. Data were exported to SPSS, data screened and descriptive statistics produced. Free text responses were analysed and tasks collated into categories reflecting the type of work involved in each task. Responses received were 393 (28%, n = 1380). Results were organised into five groups: i.e., hospital, community, primary care, General Practitioner (GP) practice and other (which included HM Prison Service). Thirty tasks were reported as commonly undertaken in three or more settings and 206 (84.7%, n = 243) pharmacy technicians reported they would like to expand their role. Tasks core to hospital and community pharmacy should be considered for inclusion to initial education standards to reflect current practice. Post qualification, pharmacy technicians indicate a significant desire to expand clinically and managerially allowing pharmacists more time in patient-facing/clinical roles.

  15. Turbine repair process, repaired coating, and repaired turbine component

    Science.gov (United States)

    Das, Rupak; Delvaux, John McConnell; Garcia-Crespo, Andres Jose

    2015-11-03

    A turbine repair process, a repaired coating, and a repaired turbine component are disclosed. The turbine repair process includes providing a turbine component having a higher-pressure region and a lower-pressure region, introducing particles into the higher-pressure region, and at least partially repairing an opening between the higher-pressure region and the lower-pressure region with at least one of the particles to form a repaired turbine component. The repaired coating includes a silicon material, a ceramic matrix composite material, and a repaired region having the silicon material deposited on and surrounded by the ceramic matrix composite material. The repaired turbine component a ceramic matrix composite layer and a repaired region having silicon material deposited on and surrounded by the ceramic matrix composite material.

  16. Electric arc spraying for restoration and repair of metallurgical equipment parts

    Directory of Open Access Journals (Sweden)

    В’ячеслав Олександрович Роянов

    2016-07-01

    Full Text Available It has been shown that the electric arc spraying with the use of powder wires can be used to repair and restore parts of metallurgical equipment. The technology of spraying parts by means of the cored wire Steelcored M8TUV; T462MMIN5 and combinations of steel and aluminum wires to restore shaft-gears, shaft-beams, cranes axles for the foundry of the Moldavian Metallurgical Plant has been introduced. The composition of the flux-cored wires MMP-2,3 developed at the Department of Equipment and welding production technology of PSTU that provides the required hardness and adhesion of the coating and the substrate have been shown and the results of the coatings properties studies have been published. Studies have shown matching properties of the coatings to be used for details of the metallurgical equipment working under difficult conditions, including the rolls of rolling mills. Cored wire was used for pilot plating of the rolls surface of the skin-rolling stand at the cold-rolling mill at Illich Steel and Iron Works, Mariupol. Residual coating thickness ranged from 15 to 25 microns. Strip sized 0,9 × 1025 mm has been rolled, the squeezing is equal to 0,8...1,0%.

  17. A WIDER ROLE FOR TECHNICIANS IN SCIENCE PRACTICAL WORK WITH SCHOOL STUDENTS?

    Directory of Open Access Journals (Sweden)

    Timothy G. Harrison

    2011-12-01

    Full Text Available This paper reports the results of a study made on the impact of improved deployment of science technicians in the classroom could directly benefit students in practical science investigations. Science technicians are skilled individuals whose understanding of practical work is a valuable resource not being used of in support of students understanding of science. Aspects of practical work and technician support were scrutinised, through information attained from a post-16 student survey to improve understanding about this teaching tool, to establish if it was being used to its full potential within science lessons. Analysis was also made of students’ perceptions of school science. The main outcomes were that the majority of students enjoyed science practical work and felt that science could not be taught without it. Students studying science at pre-university level attained a greater understanding, through participating in relevant practical work, than students who had studied it at earlier, compulsory levels. Students reported that science technicians provide impact on student learning when contact time was the greatest.

  18. Pulmonary Foreign Body Granulomatosis in Dental Technician.

    Science.gov (United States)

    Chung, Sung Jun; Koo, Gun Woo; Park, Dong Won; Kwak, Hyun Jung; Yhi, Ji Young; Moon, Ji-Yong; Kim, Sang-Heon; Sohn, Jang Won; Yoon, Ho Joo; Shin, Dong Ho; Park, Sung Soo; Pyo, Ju Yeon; Oh, Young-Ha; Kim, Tae-Hyung

    2015-10-01

    Occupational lung diseases are caused by several toxic substances including heavy metals; however, the exact pathologic mechanisms remain unknown. In the workplace, dental technicians are often exposed to heavy metals such as cobalt, nickel, or beryllium and occasionally develop occupational lung diseases. We described a case of occupational lung disease in a patient who was employed as a dental technician for over a decade. A 31-year-old, non-smoking woman presented with productive cough and shortness of breath of several weeks duration. Chest computed tomography revealed a large number of scattered, bilateral small pulmonary nodules throughout the lung field, and multiple mediastinal lymph nodes enlargement. Percutaneous needle biopsy showed multifocal small granulomas with foreign body type giant cells suggestive of heavy metals inhalation. The patient's condition improved on simple avoidance strategy for several months. This case highlighted the importance of proper workplace safety.

  19. Electrical Power and Illumination Systems. Energy Technology Series.

    Science.gov (United States)

    Center for Occupational Research and Development, Inc., Waco, TX.

    This course in electrical power and illumination systems is one of 16 courses in the Energy Technology Series developed for an Energy Conservation-and-Use Technology curriculum. Intended for use in two-year postsecondary technical institutions to prepare technicians for employment, the courses are also useful in industry for updating employees in…

  20. Investigating laparoscopic psychomotor skills in veterinarians and veterinary technicians.

    Science.gov (United States)

    Kilkenny, Jessica; Santarossa, Amanda; Mrotz, Victoria; Walker, Meagan; Monaghan, Dominique; Singh, Ameet

    2017-04-01

    To determine the influence of age, year of graduation, and video game experience on baseline laparoscopic psychomotor skills. Cross-sectional. Licensed veterinarians (n = 38) and registered veterinary technicians (VTs) (n = 49). A laparoscopic box trainer was set up at the 2016 Ontario Veterinary Medical Association (OVMA) and the 2016 Ontario Association of Veterinary Technicians (OAVT) conferences held in Toronto, Ontario, Canada. Participants volunteered to perform a single repetition of a peg transfer (PT) exercise. Participants were given a short demonstration of the PT task prior to testing. A Spearman's rank correlation (r s ) was used to identify associations between baseline psychomotor skills and self-reported surgical and non-surgical experiences collected via survey. Mann-Whitney U tests were used to compare PT scores in veterinarians and VTs. A P-value of  .05). Veterinary technicians that frequently used chopsticks scored higher than those without chopstick experience (P = .04). Age and year of graduation correlated inversely, while self-reported VG experience correlated positively with laparoscopic psychomotor skills of veterinarians, when assessed on a simulator. The use of chopsticks may contribute to the acquisition of psychomotor skills in VTs. © 2017 The American College of Veterinary Surgeons.

  1. Staphylococcus aureus with Panton-Valentine toxin skin infection in a medical laboratory technician.

    Science.gov (United States)

    Pougnet, Richard; Pougnet, Laurence

    2016-12-01

    This report exposes the case of a Staphylococcus aureus infection occurring in a microbiology laboratory technician. He was a 52 year-old man without medical history. He presented an abscess on the anterior aspect of the left forearm. Analysis showed that it was a Staphylococcus aureus secreting the Panton-Valentine toxin. The study of the workplace found the frequency of exposure. The study of workstation showed the link between the technician position and the infection. Indeed, this man touched an area where the biocleaning was hard to do. This is the first case of infection with PVL described for a laboratory technician.

  2. Role of the chemical engineering technician in applied research related to tritium separation from aqueous effluents

    International Nuclear Information System (INIS)

    Nelson, S.D.

    1978-01-01

    Applied research and development activities related to the removal of tritium from aqueous effluent streams have presented broad opportunities to the chemical engineering technician for professional growth. Technician job activities involve operating complex analytical instrumentation and constructing, maintaining, and operating experimental electrolysis apparatus. The technician is a member of a professional team including scientific, engineering, and other technical personnel and as such is expected to exercise creative thought. Proximity of a large university and availability of formalized ''in house'' training courses provide incentives for technicians to broaden their academic base concurrent with their work involvement

  3. Fuzzy hybrid MCDM approach for selection of wind turbine service technicians

    Directory of Open Access Journals (Sweden)

    Goutam Kumar Bose

    2016-01-01

    Full Text Available This research paper is aimed to present a fuzzy Hybrid Multi-criteria decision making (MCDM methodology for selecting employees. The present study aspires to present the hybrid approach of Fuzzy multiple MCDM techniques with tactical viewpoint to support the recruitment process of wind turbine service technicians. The methodology is based on the application of Fuzzy ARAS (Additive Ratio Assessment and Fuzzy MOORA (Multi-Objective Optimization on basis of Ratio Analysis which are integrated through group decision making (GDM method in the model for selection of wind turbine service technicians’ ranking. Here a group of experts from different fields of expertise are engaged to finalize the decision. Series of tests are conducted regarding physical fitness, technical written test, practical test along with general interview and medical examination to facilitate the final selection using the above techniques. In contrast to single decision making approaches, the proposed group decision making model efficiently supports the wind turbine service technicians ranking process. The effectiveness of the proposed approach manifest from the case study of service technicians required for the maintenance department of wind power plant using Fuzzy ARAS and Fuzzy MOORA. This set of potential technicians is evaluated based on five main criteria.

  4. So You Want to Train Solar Technicians.

    Science.gov (United States)

    Ensign, M. Dale; Richins, Michael Paul

    1978-01-01

    Considers the role of solar energy in meeting the nation's energy requirements and the future needs for solar technicians and mechanics. Discusses the precautions community colleges must take in training these workers, to ensure that the demand be met without flooding the job market. (MB)

  5. Understanding safety climate in small automobile collision repair shops.

    Science.gov (United States)

    Parker, David L; Brosseau, Lisa M; Bejan, Anca; Skan, Maryellen; Xi, Min

    2014-01-01

    In the United States, approximately 236,000 people work in 37,600 auto collision-repair businesses. Workers in the collision-repair industry may be exposed to a wide range of physical and chemical hazards. This manuscript examines the relationship of safety climate as reported by collision repair shop workers and owners to: (1) an independent business safety assessment, and (2) employee self-reported work practices. The study was conducted in the Twin Cities metropolitan area. A total of 199 workers from 49 collision shops completed a survey of self-reported work practices and safety climate. Surveys were completed by an owner or manager in all but three shops. In general, self-reported work practices were poor. Workers' scores on safety climate were uniformly lower than those of owners. For workers, there was no correlation between how well the business scored on an independent audit of business safety practices and the safety climate measures they reported. For owners, however, there was a positive correlation between safety climate scores and the business safety assessment. For workers, safety rules and procedures were associated with improved work practices for those engaged in both painting-related and body technician-related activities. The enforcement of safety rules and procedures emerged as a strong factor positively affecting self-reported work practices. These findings identify a simple, cost effective path to reducing hazards in small workplaces. © 2013 Wiley Periodicals, Inc.

  6. Piezoelectric materials as stimulatory biomedical materials and scaffolds for bone repair.

    Science.gov (United States)

    Tandon, Biranche; Blaker, Jonny J; Cartmell, Sarah H

    2018-04-16

    The process of bone repair and regeneration requires multiple physiological cues including biochemical, electrical and mechanical - that act together to ensure functional recovery. Myriad materials have been explored as bioactive scaffolds to deliver these cues locally to the damage site, amongst these piezoelectric materials have demonstrated significant potential for tissue engineering and regeneration, especially for bone repair. Piezoelectric materials have been widely explored for power generation and harvesting, structural health monitoring, and use in biomedical devices. They have the ability to deform with physiological movements and consequently deliver electrical stimulation to cells or damaged tissue without the need of an external power source. Bone itself is piezoelectric and the charges/potentials it generates in response to mechanical activity are capable of enhancing bone growth. Piezoelectric materials are capable of stimulating the physiological electrical microenvironment, and can play a vital role to stimulate regeneration and repair. This review gives an overview of the association of piezoelectric effect with bone repair, and focuses on state-of-the-art piezoelectric materials (polymers, ceramics and their composites), the fabrication routes to produce piezoelectric scaffolds, and their application in bone repair. Important characteristics of these materials from the perspective of bone tissue engineering are highlighted. Promising upcoming strategies and new piezoelectric materials for this application are presented. Electrical stimulation/electrical microenvironment are known effect the process of bone regeneration by altering the cellular response and are crucial in maintaining tissue functionality. Piezoelectric materials, owing to their capability of generating charges/potentials in response to mechanical deformations, have displayed great potential for fabricating smart stimulatory scaffolds for bone tissue engineering. The growing

  7. Accuracy of densitometric vertebral fracture assessment when performed by DXA technicians-a cross-sectional, multiobserver study

    DEFF Research Database (Denmark)

    Rud, B; Vestergaard, A; Hyldstrup, L

    2016-01-01

    Six dual-energy X-ray absorptiometry (DXA) technicians reviewed lateral images of the spine for deformed vertebrae. The images were acquired with a DXA scanner in 235 patients referred for osteoporosis assessment. The outcome was compared to findings on spinal radiographs assessed by two radiolog......Six dual-energy X-ray absorptiometry (DXA) technicians reviewed lateral images of the spine for deformed vertebrae. The images were acquired with a DXA scanner in 235 patients referred for osteoporosis assessment. The outcome was compared to findings on spinal radiographs assessed by two...... radiologists. Three DXA technicians performed acceptable or better in identifying patients with fractured vertebrae. INTRODUCTION: This is the first study to evaluate the accuracy of vertebral fracture assessment (VFA) when used by DXA technicians as a triage test to select patients with deformed vertebrae...... for spinal radiographs. METHODS: Lateral single-energy scans and radiographs of the thoracolumbar spine (T4-L4) were acquired in 235 patients aged 65 years or more referred for osteoporosis assessment. Six DXA technicians evaluated lateral scans using dedicated software. The DXA technicians were trained...

  8. [EEG technician-nurse collaboration during stereo-electroencephalography].

    Science.gov (United States)

    Jomard, Caroline; Benghezal, Mouna; Cheramy, Isabelle; De Beaumont, Ségolène

    2017-01-01

    Drug-resistant epilepsy has significant repercussions on the daily life of children. Surgery may represent a hope. The nurse and the electroencephalogram technician carry out important teamwork during pre-surgical assessment tests and notably the stereo-electroencephalography. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  9. Job Satisfaction among Turkish Business Aviation Technicians

    Directory of Open Access Journals (Sweden)

    Tevfik Uyar

    2013-09-01

    Full Text Available The most applicable models in safety management put the human factors, employers’ attitudes and behaviors at the center. This study reports an investigation of job satisfaction among business aviation technicians. A demographic information form and Job Satisfaction Survey (JSS were used to collect data from 44 individuals. Data was analyzed using ANOVA and Student’s t-test. Our results show that there is significant difference in total job satisfaction levels with regard to marital status while other personal factors are not related to the total job satisfaction levels. However several sub dimensions of job satisfaction are affected by the workers’ military or civilian origin, their training background, types of companies they work in or their license category. No difference is found in age and position groups. Secondly, study shows that technicians are the most satisfied from the nature of their work, while they are the least satisfied by operational procedures.

  10. 40 CFR 745.92 - Fees for the accreditation of renovation and dust sampling technician training and the...

    Science.gov (United States)

    2010-07-01

    ... renovation and dust sampling technician training and the certification of renovation firms. 745.92 Section... Renovation § 745.92 Fees for the accreditation of renovation and dust sampling technician training and the... the following disciplines: Renovator, dust sampling technician. (ii) Exemption. No fee shall be...

  11. Radiological Control Technician: Phase 2, Core/site practical training

    International Nuclear Information System (INIS)

    1992-10-01

    This volume provides a description of the guidelines, qualification in radiological instrumentation, qualification in radiological protection, and qualification in emergency preparedness for radiological control technicians

  12. Building an adaptive agent to monitor and repair the electrical power system of an orbital satellite

    Science.gov (United States)

    Tecuci, Gheorghe; Hieb, Michael R.; Dybala, Tomasz

    1995-01-01

    Over several years we have developed a multistrategy apprenticeship learning methodology for building knowledge-based systems. Recently we have developed and applied our methodology to building intelligent agents. This methodology allows a subject matter expert to build an agent in the same way in which the expert would teach a human apprentice. The expert will give the agent specific examples of problems and solutions, explanations of these solutions, or supervise the agent as it solves new problems. During such interactions, the agent learns general rules and concepts, continuously extending and improving its knowledge base. In this paper we present initial results on applying this methodology to build an intelligent adaptive agent for monitoring and repair of the electrical power system of an orbital satellite, stressing the interaction with the expert during apprenticeship learning.

  13. Effects of occupational exposure of X-Ray on hematological parameters of diagnostic technicians

    Science.gov (United States)

    Taqi, Ali H.; Faraj, Kharman A.; Zaynal, Sarah A.; Hameed, Ahmed M.; Mahmood, Abd-Alkader A.

    2018-06-01

    The aim of this study was to identify the effects of long term exposure of X-ray on diagnostic technicians which they work at Kirkuk hospitals through examining some hematological parameters which are white blood cells (WBC), Neutrophils, Lymphocyte, Monocyte, Eosinophil, Basophil, Reactive Lymphocyte, red blood cells (RBC), hemoglobin (Hb), hematocrit (HCT), Mean Cell Volume (MCV), Mean Corpuscular Hemoglobin (MCH), Mean Cell Hemoglobin Concentration (MCHC), Red Cell Distribution Width (RDW), Platelet (PLT). The study included 54 male diagnostic technicians and 54 male healthy controls match with the first group to show any alteration of the hematological parameters. The diagnostic technicians divided into two groups depending on their work experience and hours working per day. The statistical analysis was performed using (Graph-pad) program. Our results showed that the Complete blood cells count (CBC) parameters (Neutrophil, Monocytes, Basophile, MCV, RDW and PLT) significantly (Pgroups of the diagnostic technicians compared with their controls. We concluded that chronic exposure of X-ray can significantly alter some hematological parameters and the number of hours working per day has observable effects on the some hematological parameters. We recommended training and courses about hazard of ionizing radiation should be organized for enhance the healthcare quality of the technicians and to improve their knowledge about benefit of radiation protection tools to protect themselves from any overexposure during the daily life.

  14. Preparing technicians for engineering materials technology

    Science.gov (United States)

    Jacobs, James A.; Metzloff, Carlton H.

    1990-01-01

    A long held principle is that for every engineer and scientist there is a need for ten technicians to maximize the efficiency of the technology team for meeting needs of industry and government. Developing an adequate supply of technicians to meet the requirements of the materials related industry will be a challenge and difficult to accomplish. A variety of agencies feel the need and wish to support development of engineering materials technology programs. In a joint effort among Battelle Laboratories, the Department of Energy (DOE) and Northwest College and University Association for Science (NORCUS), the development of an engineering materials technology program for vocational programs and community colleges for the Pacific Northwest Region was recently completed. This effort has implications for a national model. The model Associate of Applied Science degree in Engineering Materials Technology shown provides a general structure. It purposely has course titles which need delimiting while also including a core of courses necessary to develop cognitive, affective and psychomotor skills with the underlining principles of math, science and technology so students have job entry skills, and so that students can learn about and adapt to evolving technology.

  15. Work group design in pharmacy: the pharmacist-technician team.

    Science.gov (United States)

    Kershaw, B P; Solomon, D K; Zarowitz, B J

    1987-05-01

    The contemporary pharmacy practice manager faces the challenge of designing pharmacy service programs that not only satisfy the needs of the patient, but at the same time satisfy and motivate the pharmacists and technicians who sustain the programs. This research examined the team design, which has been recommended but not fully described in the literature. This application did not explore the full potential of the team design in the hospital pharmacy setting. More study is needed in this area to assess the impact of work group design on the expansion of clinical programs, employee turnover rates, quality and quantity of work produced, and, most important, the impact on job satisfaction enjoyed by pharmacists and technicians.

  16. Practical digital electronics for technicians

    CERN Document Server

    Kimber, Will

    2013-01-01

    Practical Digital Electronics for Technicians covers topics on analog and digital signals, logic gates, combinational logic, and Karnaugh mapping. The book discusses the characteristics and types of logic families; sequential systems including latch, bistable circuits, counters and shift registers; Schmitt triggers and multivibrators; and MSI combinational logic systems. Display devices, including LED, LCD and dot matrix display; analog and digital conversion; and examples of and equipment for digital fault finding are also considered. The book concludes by providing answers to the questions

  17. Rapid methods for jugular bleeding of dogs requiring one technician.

    Science.gov (United States)

    Frisk, C S; Richardson, M R

    1979-06-01

    Two methods were used to collect blood from the jugular vein of dogs. In both techniques, only one technician was required. A rope with a slip knot was placed around the base of the neck to assist in restraint and act as a tourniquet for the vein. The technician used one hand to restrain the dog by the muzzle and position the head. The other hand was used for collecting the sample. One of the methods could be accomplished with the dog in its cage. The bleeding techniques were rapid, requiring approximately 1 minute per dog.

  18. Defining the Role of the Pharmacy Technician and Identifying Their Future Role in Medicines Optimisation

    Science.gov (United States)

    Boughen, Melanie; Sutton, Jane; Fenn, Tess

    2017-01-01

    Background: Traditionally, pharmacy technicians have worked alongside pharmacists in community and hospital pharmacy. Changes within pharmacy provide opportunity for role expansion and with no apparent career pathway, there is a need to define the current pharmacy technician role and role in medicines optimisation. Aim: To capture the current roles of pharmacy technicians and identify how their future role will contribute to medicines optimisation. Methods: Following ethical approval and piloting, an online survey to ascertain pharmacy technicians’ views about their roles was undertaken. Recruitment took place in collaboration with the Association of Pharmacy Technicians UK. Data were exported to SPSS, data screened and descriptive statistics produced. Free text responses were analysed and tasks collated into categories reflecting the type of work involved in each task. Results: Responses received were 393 (28%, n = 1380). Results were organised into five groups: i.e., hospital, community, primary care, General Practitioner (GP) practice and other (which included HM Prison Service). Thirty tasks were reported as commonly undertaken in three or more settings and 206 (84.7%, n = 243) pharmacy technicians reported they would like to expand their role. Conclusions: Tasks core to hospital and community pharmacy should be considered for inclusion to initial education standards to reflect current practice. Post qualification, pharmacy technicians indicate a significant desire to expand clinically and managerially allowing pharmacists more time in patient-facing/clinical roles. PMID:28970452

  19. Oral health technicians in Brazilian primary health care: potentials and constraints.

    Science.gov (United States)

    Aguiar, Dulce Maria Lucena de; Tomita, Nilce Emy; Machado, Maria de Fátima Antero Sousa; Martins, Cleide Lavieri; Frazão, Paulo

    2014-07-01

    Different perspectives on the role of mid-level workers in health care might represent a constraint to health policies. This study aimed to investigate how different agents view the participation of oral health technicians in direct activities of oral healthcare with the goal of understanding the related symbolic dispositions. Theoretical assumptions related to inter-professional collaboration and conflicts in the field of healthcare were used for this analysis. A researcher conducted 24 in-depth interviews with general dental practitioners, oral health technicians and local managers. The concepts of Pierre Bourdieu supported the data interpretation. The results indicated inter-professional relations marked by collaboration and conflict that reflect an action space related to different perspectives of primary care delivery. They also unveiled the symbolic devices related to the participation of oral health technicians that represent a constraint to the implementation of oral health policy, thus reducing the potential of primary health care in Brazil.

  20. The nuclear industry is looking for its technicians; Le nucleaire cherche ses techniciens

    Energy Technology Data Exchange (ETDEWEB)

    Dumas, A

    2010-03-15

    With massive retirements planned up to 2015, the French nuclear industry wishes to recruit technicians for the operation and maintenance of its power plants. The French nuclear park represents 19 power plants with 58 reactors. The nuclear industry personnel represents 19000 people at EdF and about 20000 people from about 600 different service provider companies. Technician's salary ranges from 1500 to 2800 euros for experienced people, bonus not included. Before being operational, the French nuclear technicians have to follow a long training period in one of the 20 specialized and certified training centres. However, the training demand is so important that the industry suffers from a lack of instructors as well. (J.S.)

  1. ENERGY EFFICIENCY OF DIESEL LOCOMOTIVE HYDRAULIC TRANSMISSION TESTS AT LOCOMOTIVE REPAIR PLANT

    Directory of Open Access Journals (Sweden)

    B. E. Bodnar

    2015-10-01

    Full Text Available Purpose. In difficult economic conditions, cost reduction of electricity consumption for the needs of production is an urgent task for the country’s industrial enterprises. Technical specifications of enterprises, which repair diesel locomotive hydraulic transmission, recommend conducting a certain amount of evaluation and regulatory tests to monitor their condition after repair. Experience shows that a significant portion of hydraulic transmission defects is revealed by bench tests. The advantages of bench tests include the ability to detect defects after repair, ease of maintenance of the hydraulic transmission and relatively low labour intensity for eliminating defects. The quality of these tests results in the transmission resource and its efficiency. Improvement of the technology of plant post-repairs hydraulic tests in order to reduce electricity consumption while testing. Methodology. The possible options for hydraulic transmission test bench improvement were analysed. There was proposed an energy efficiency method for diesel locomotive hydraulic transmission testing in locomotive repair plant environment. This is achieved by installing additional drive motor which receives power from the load generator. Findings. Based on the conducted analysis the necessity of improving the plant stand testing of hydraulic transmission was proved. The variants of the stand modernization were examined. The test stand modernization analysis was conducted. Originality. The possibility of using electric power load generator to power the stand electric drive motor or the additional drive motor was theoretically substantiated. Practical value. A variant of hydraulic transmission test stand based on the mutual load method was proposed. Using this method increases the hydraulic transmission load range and power consumption by stand remains unchanged. The additional drive motor will increase the speed of the input shaft that in its turn wil allow testing in

  2. Repair process and a repaired component

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, III, Herbert Chidsey; Simpson, Stanley F.

    2018-02-20

    Matrix composite component repair processes are disclosed. The matrix composite repair process includes applying a repair material to a matrix composite component, securing the repair material to the matrix composite component with an external securing mechanism and curing the repair material to bond the repair material to the matrix composite component during the securing by the external securing mechanism. The matrix composite component is selected from the group consisting of a ceramic matrix composite, a polymer matrix composite, and a metal matrix composite. In another embodiment, the repair process includes applying a partially-cured repair material to a matrix composite component, and curing the repair material to bond the repair material to the matrix composite component, an external securing mechanism securing the repair material throughout a curing period, In another embodiment, the external securing mechanism is consumed or decomposed during the repair process.

  3. Electronics technician Bill Clark assembling a cannon plug with the help of Jim Lewis

    Science.gov (United States)

    1991-01-01

    There is always something needed for a NASA aircraft before a research flight can take place. This photo shows William J. Clark working on one of those 'somethings' while Jimmie C. Lewis watches ready to help. Working on a research project is a challenge, for there is no set pattern to follow. From the drawings to the final product there are many people who contribute to that final product -- the flight. The electronic technicians in the Instrumentation Laboratory at NASA Ames-Dryden Flight Research Facility are no exception. Bill Clark is busy creating a cannon plug to be used on the CV-990. He is soldering wires in the appropriate order so the plug will transmit electrical currents correctly when installed in the airplane. Jim stands by to give help and support on the project.

  4. Properties shaping and repair of selected types of cast iron

    Directory of Open Access Journals (Sweden)

    J. Szajnar

    2007-04-01

    Full Text Available The paper presents research results of twofold use of TIG - Tungsten Inert Gas also known as GTA - Gas Tungsten Arc. First is surfacing by welding on cold and hot-cold to repair chromium cast iron with chromium content about 15%. Second is remelting with electric arc of selected gray (with pearlitic matrix and ductile (with ferritic-pearlitic matrix cast iron. Repair of cast iron elements was realized in order to cut out a casting defects. Defects decrease a usability of castings for constructional application and increase a manufacturing costs. Application of surface heat treatment guarantees mechanical properties i.e. hardness and wear resistance improvement. The result of investigations show possibility of castings repair by put on defects a good quality padding welds, which have comparable properties with base material. Use of electric arc surface heat treatment resulted in increase of hardness and wear resistance, which was measured on the basis of ASTM G 65 - 00 standard.

  5. Electrophysiological Assessment of a Peptide Amphiphile Nanofiber Nerve Graft for Facial Nerve Repair.

    Science.gov (United States)

    Greene, Jacqueline J; McClendon, Mark T; Stephanopoulos, Nicholas; Álvarez, Zaida; Stupp, Samuel I; Richter, Claus-Peter

    2018-04-27

    Facial nerve injury can cause severe long-term physical and psychological morbidity. There are limited repair options for an acutely transected facial nerve not amenable to primary neurorrhaphy. We hypothesize that a peptide amphiphile nanofiber neurograft may provide the nanostructure necessary to guide organized neural regeneration. Five experimental groups were compared, animals with 1) an intact nerve, 2) following resection of a nerve segment, and following resection and immediate repair with either a 3) autograft (using the resected nerve segment), 4) neurograft, or 5) empty conduit. The buccal branch of the rat facial nerve was directly stimulated with charge balanced biphasic electrical current pulses at different current amplitudes while nerve compound action potentials (nCAPs) and electromygraphic (EMG) responses were recorded. After 8 weeks, the proximal buccal branch was surgically re-exposed and electrically evoked nCAPs were recorded for groups 1-5. As expected, the intact nerves required significantly lower current amplitudes to evoke an nCAP than those repaired with the neurograft and autograft nerves. For other electrophysiologic parameters such as latency and maximum nCAP, there was no significant difference between the intact, autograft and neurograft groups. The resected group had variable responses to electrical stimulation, and the empty tube group was electrically silent. Immunohistochemical analysis and TEM confirmed myelinated neural regeneration. This study demonstrates that the neuroregenerative capability of peptide amphiphile nanofiber neurografts is similar to the current clinical gold standard method of repair and holds potential as an off-the-shelf solution for facial reanimation and potentially peripheral nerve repair. This article is protected by copyright. All rights reserved.

  6. Does pneumoconiosis of dental technician cause to calcific pleural lesions? (Case report

    Directory of Open Access Journals (Sweden)

    Abdurrahman ŞENYİĞİT

    2009-03-01

    Full Text Available The articles about various pneumoconiosis in dental technicians who work in inconvenient conditions have been increasing in recent years. Exposure to dust and fume that occur during the dental procedure may play role in pneumoconiosis of dental technicians.A 53 years old male patient conveyed that he has worked in dental prosthesis procedures for 22 years (1968-1990.Environmental asbestosis was not established in the history of the case but there were calcified pleural plaques in the chest x-ray graphy.There were appearance of calcific asbest plaques in many section of thorax CT.A case of pneumoconiosis in dental technician who work in unadequate preventive conditions was reported in this paper. Probably ,exposure to the asbest fibers that occurs during the procedure of dental prosthesis were the main reason for developing calcific pleural lesions.

  7. Fulbright project focuses on rehabilitation technician education and ...

    African Journals Online (AJOL)

    Rehabilitation technician education and physiotherapy practice 272. Fulbright project focuses on ... particularly those qualified to mentor and teach entry-level learners, there are ... to reinforce classroom didactic knowledge as ongoing learning .... utilization of limited resources, and development of linkages with professional ...

  8. Task Analysis and Job Descriptions for Robotics/Automated Systems Technicians. Final Report. Volume 1.

    Science.gov (United States)

    Hull, Daniel M.; Lovett, James E.

    The Robotics/Automated Systems Technician (RAST) project developed a robotics technician model curriculum for the use of state directors of vocational education and two-year college vocational/technical educators. A baseline management plan was developed to guide the project. To provide awareness, project staff developed a dissemination plan…

  9. Examining Career Success of Minority and Women Emergency Medical Technicians (EMTs): A LEADS Project

    Science.gov (United States)

    Russ-Eft, Darlene F.; Dickison, Philip D.; Levine, Roger

    2008-01-01

    Emergency medical technicians (EMTs) are a critical segment in prehospital medical care. This study examined EMT-paramedic career success focused on minorities and women, as part of the Longitudinal Emergency Medical Technician Attributes and Demographics Study (LEADS). The LEADS data come from a representative sampling of EMTs throughout the…

  10. The practical training of students - x-ray technicians and requirements to mentors in clinical bases

    International Nuclear Information System (INIS)

    Gagova, P; Boninska, N.; Jovchev, D.

    2012-01-01

    Full text: Introduction: Training of X-ray technicians in Bulgaria takes place in the Medical Colleges to Medical Universities. It's purpose is providing professional training of students in the area of diagnostic imaging, nuclear medicine and radiotherapy. Practical training is based on the scientific and theoretical knowledge and skills and is organized in pedagogic environment, adequate to regularities for a gradual formation of practical skills and habits. The practical training and pre-graduation internship are performed in 1895 from total of 3810 hours, which represents about fifty percent of all training of X-ray technicians. Students are in groups of 2-4 students. Practical training is organized, accomplished and monitored by the teacher training practice with the help of a mentor in the clinical base. Purpose: To present the tasks of practical training of students - X-ray technicians and the requirements for the personal characteristics and activity of mentors. Materials and methods: Documentary method has been used. Literature and normative documents related to the practical training of students in 'X-ray technician' of Medical Colleges have been studied. The job descriptions of senior clinical X-ray technicians have been examined carefully. Results: By analyzing literature sources, we have structured the tasks of practical training and pre-graduation internship of students - X-ray technicians, also we have described the requirements for personal qualities of mentors and systematize the activities they perform. Conclusion: Practical training plays an important role in adaptation of young X-ray technicians to the conditions of medical work, improving their skills and habits, and to the development of specific practical skills for being able to respond to emergency conditions and to solve complicated practical situations. The mentor is the supervisor and the controller of interns who helps this happen through his own example, qualities and attitudes towards

  11. IAEA Technical Co-operation activities: Asia and the Pacific. Workshop on training nuclear laboratory technicians

    International Nuclear Information System (INIS)

    Roeed, S.S.

    1976-01-01

    The workshop was held to exchange information on existing facilities and programmes in Asia and the Pacific for training nuclear laboratory technicians, to identify future training needs and to assess the need for IAEA's involvement in this field. As the participants outlined the requirements for nuclear laboratory technician training and the facilities available in their respective countries, it became evident that, in addition to the training of radioisotope laboratory technicians, they also wished to review the need for technician training for the operation of nuclear power plants and industrial application of atomic energy. The terms of reference of the workshop were extended accordingly. The opening address by Chang Suk Lee, the Korean Vice Minister of Science and Technology, noted the valuable contribution to quality control and other industrial uses that nuclear techniques have made in his country. He also reviewed the application of nuclear techniques in Korean agriculture and medicine. The participants explored various forms of co-operation that could be established between countries of the region. Exchange programmes, not only for students but also for expert teachers, and the exchange or loan of equipment were suggested. It was felt that some generalized training courses could be organized on a regional basis, and two countries advocated the setting up of a regional training centre. One suggestion was to arrange regional training courses in special fields that would move from one country to another. The need was felt for periodic regional meetings on training methods, course content and other questions relating to training of laboratory technicians. The IAEA was requested to act as a clearinghouse for information on available training facilities in the region and to advise on the curricula for technician training courses. The Agency was also asked to organize short courses for the training of instructors of technicians in the various fields of atomic

  12. Electrical circuit theory and technology

    CERN Document Server

    Bird, John

    2014-01-01

    This much-loved textbook explains the principles of electrical circuit theory and technology so that students of electrical and mechanical engineering can master the subject. Real-world situations and engineering examples put the theory into context. The inclusion of worked problems with solutions help you to learn and further problems then allow you to test and confirm you have fully understood each subject. In total the book contains 800 worked problems, 1000 further problems and 14 revision tests with answers online. This an ideal text for foundation and undergraduate degree students and those on upper level vocational engineering courses, in particular electrical and mechanical. It provides a sound understanding of the knowledge required by technicians in fields such as electrical engineering, electronics and telecommunications. This edition has been updated with developments in key areas such as semiconductors, transistors, and fuel cells, along with brand new material on ABCD parameters and Fourier's An...

  13. Rural emergency medical technician pre-hospital electrocardiogram transmission.

    Science.gov (United States)

    Powell, A M; Halon, J M; Nelson, J

    2014-01-01

    Emergent care of the acute heart attack patient continues to be at the forefront of quality and cost reduction strategies throughout the healthcare industry. Although the average cardiac door-to-balloon (D2B) times have decreased substantially over the past few years, there are still vast disparities found in D2B times in populations that reside in rural areas. Such disparities are mostly related to prolonged travel time and subsequent delays in cardiac catherization lab team activation. Urban ambulance companies that are routinely staffed with paramedic level providers have been successful in the implementation of pre-hospital 12-lead electrocardiogram (ECG) protocols as a strategy to reduce D2B times. The authors sought to evaluate the evidence related to the risk and benefits associated with the replication of an ECG transmission protocol in a small rural emergency medical service. The latter is staffed with emergency medical technician-basics (EMT-B), emergency medical technician-advanced (EMT-A), and emergency medical technician-intermediate (EMT-I) level. The evidence reviewed was limited to studies with relevant data regarding the challenges and complexities of the ECG transmission process, the difficulties associated with ECG transmission in rural settings, and ECG transmission outcomes by provider level. The evidence supports additional research to further evaluate the feasibility of ECG transmission at the non-paramedic level. Multiple variables must be investigated including equipment cost, utilization, and rural transmission capabilities. Clearly, pre-hospital ECG transmission and early activation of the cardiac catheterization laboratory are critical components to successfully decreasing D2B times.

  14. Promoting peripheral myelin repair.

    Science.gov (United States)

    Zhou, Ye; Notterpek, Lucia

    2016-09-01

    Compared to the central nervous system (CNS), peripheral nerves have a remarkable ability to regenerate and remyelinate. This regenerative capacity to a large extent is dependent on and supported by Schwann cells, the myelin-forming glial cells of the peripheral nervous system (PNS). In a variety of paradigms, Schwann cells are critical in the removal of the degenerated tissue, which is followed by remyelination of newly-regenerated axons. This unique plasticity of Schwann cells has been the target of myelin repair strategies in acute injuries and chronic diseases, such as hereditary demyelinating neuropathies. In one approach, the endogenous regenerative capacity of Schwann cells is enhanced through interventions such as exercise, electrical stimulation or pharmacological means. Alternatively, Schwann cells derived from healthy nerves, or engineered from different tissue sources have been transplanted into the PNS to support remyelination. These transplant approaches can then be further enhanced by exercise and/or electrical stimulation, as well as by the inclusion of biomaterial engineered to support glial cell viability and neurite extension. Advances in our basic understanding of peripheral nerve biology, as well as biomaterial engineering, will further improve the functional repair of myelinated peripheral nerves. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Scheduling technicians and tasks in a telecommunications company

    DEFF Research Database (Denmark)

    Cordeau, J. F.; Laporte, G.; Pasin, F.

    2010-01-01

    This paper proposes a construction heuristic and an adaptive large neighborhood search heuristic for the technician and task scheduling problem arising in a large telecommunications company. This problem was solved within the framework of the 2007 challenge set up by the French Operational Research...

  16. Radiological Control Technician: Phase 1, Site academic training lesson plans

    International Nuclear Information System (INIS)

    1992-10-01

    This volume provides lesson plans for training radiological control technicians. Covered here is basic radiological documentation, counting errors, dosimetry, environmental monitoring, and radiation instruments

  17. 29 CFR 1915.132 - Portable electric tools.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Portable electric tools. 1915.132 Section 1915.132 Labor... § 1915.132 Portable electric tools. The provisions of this section shall apply to ship repairing... frames of portable electric tools and appliances, except double insulated tools approved by Underwriters...

  18. Radiation Technician Scientist service

    International Nuclear Information System (INIS)

    Prieto Miranda, Enrique; Barrera Gonzalez, Gisela; Guerra Torres, Mercedes; Mora Lopez, Leonor; Altanes Valentin, Sonia; Rapado Paneque, Manuel; Plasencia Gutierrez, Manuel

    2003-01-01

    The irradiation service is part of the specialized technician scientist services of the Center of Technological Applications and Nuclear Development it belonging to the Radiobiological Department it provides a self shielded laboratory irradiator, PX y 30 type with Cobalt 60 sources, it destined for searches studies, so much basic as applying, in several branches of the science, like the radiobiology, the radiation chemistry, the solid state physics, the medicine, the agriculture and the Pharmaceutical- Medical Industry and besides offering the irradiation service properly with the which have been gotten significant economical outputs. The radiation processing is controlled by means of the dosimetric systems of Freckle, ceric cerous sulfate, Perspex (red, clear and Amber) and dose indicators

  19. The Newnes guide to home electrics

    CERN Document Server

    Burdett, Geoffrey

    2013-01-01

    Home Electrics, Second Edition provides a do-it-yourself (DIY) guide to residential electric systems. The book is comprised of 15 chapters that cover the different aspects of home electrics. The topics covered in the text include electrical installation, rewiring, power circuits, electrical hardware, electrical repairs, tools, and safety. The book also discusses a specific area or function of home electronics, such as lighting system, lamps, electric cookers, and outdoor electrical extension. The book will be of great use to individuals interested in learning how to conduct proper home electri

  20. Technicians dismantle the inner section of L3

    CERN Multimedia

    Laurent Guiraud

    2001-01-01

    The technicians are dismantling the forward tracking chamber located at the heart of the L3 detector. This formed part of the hadronic calorimeter, which is used for measuring particle energies. L3 was an experiment at the LEP collider that ran from 1989 to 2000.

  1. Organizing Consumers for a Decarbonized Electricity System

    DEFF Research Database (Denmark)

    Pallesen, Trine; Jenle, Rasmus Ploug

    2018-01-01

    This paper studies a Danish smart grid experiment, EcoGrid EU, designed to sustain the increase of wind power in the electricity system. EcoGrid EU is designed as a real-time market, through which engineers seek to realize price responsive electricity consumers through the introduction of smart...... meters, variable short-term price signals and training users. Based on observations and interviews with scientist, consumers and technicians, this paper analyses the attempt to produce a new kind of electricity consumer. Drawing on social studies of markets, we argue that the project entails constructing...... a new form of calculative agency. We illustrate the extensive work put into the creation of a new, reconfigured electricity consumer, as well as the challenges associated with the construction of consumers willing and able to act in accordance with the EcoGrid script. On one hand, this study adds...

  2. Computer Vision Tool and Technician as First Reader of Lung Cancer Screening CT Scans.

    Science.gov (United States)

    Ritchie, Alexander J; Sanghera, Calvin; Jacobs, Colin; Zhang, Wei; Mayo, John; Schmidt, Heidi; Gingras, Michel; Pasian, Sergio; Stewart, Lori; Tsai, Scott; Manos, Daria; Seely, Jean M; Burrowes, Paul; Bhatia, Rick; Atkar-Khattra, Sukhinder; van Ginneken, Bram; Tammemagi, Martin; Tsao, Ming Sound; Lam, Stephen

    2016-05-01

    To implement a cost-effective low-dose computed tomography (LDCT) lung cancer screening program at the population level, accurate and efficient interpretation of a large volume of LDCT scans is needed. The objective of this study was to evaluate a workflow strategy to identify abnormal LDCT scans in which a technician assisted by computer vision (CV) software acts as a first reader with the aim to improve speed, consistency, and quality of scan interpretation. Without knowledge of the diagnosis, a technician reviewed 828 randomly batched scans (136 with lung cancers, 556 with benign nodules, and 136 without nodules) from the baseline Pan-Canadian Early Detection of Lung Cancer Study that had been annotated by the CV software CIRRUS Lung Screening (Diagnostic Image Analysis Group, Nijmegen, The Netherlands). The scans were classified as either normal (no nodules ≥1 mm or benign nodules) or abnormal (nodules or other abnormality). The results were compared with the diagnostic interpretation by Pan-Canadian Early Detection of Lung Cancer Study radiologists. The overall sensitivity and specificity of the technician in identifying an abnormal scan were 97.8% (95% confidence interval: 96.4-98.8) and 98.0% (95% confidence interval: 89.5-99.7), respectively. Of the 112 prevalent nodules that were found to be malignant in follow-up, 92.9% were correctly identified by the technician plus CV compared with 84.8% by the study radiologists. The average time taken by the technician to review a scan after CV processing was 208 ± 120 seconds. Prescreening CV software and a technician as first reader is a promising strategy for improving the consistency and quality of screening interpretation of LDCT scans. Copyright © 2016 International Association for the Study of Lung Cancer. Published by Elsevier Inc. All rights reserved.

  3. Time to pregnancy among Danish laboratory technicians who were a part of the National Birth Cohort

    DEFF Research Database (Denmark)

    Zhu, Jin Liang; Knudsen, Lisbeth E; Andersen, Anne-Marie Nybo

    2005-01-01

    in 1997-2003. Altogether 6250 female teachers formed the reference group. A discrete-time survival analysis with a complementary log-log link was applied to estimate the fecundability ratio between the exposed and unexposed women, with adjustment for maternal age, gravidity, smoking, prepregnancy body......OBJECTIVES: The Danish National Birth Cohort was used to examine whether laboratory work was associated with reduced fecundity. METHODS: Self-reported data on laboratory work and waiting time to pregnancy (0-2, 3-5, 6-12 and > 12 months) were used for 829 female laboratory technicians interviewed...... mass index, and paternal job. RESULTS: No difference in time to pregnancy was found between the laboratory technicians and teachers or between the laboratory technicians with different exposures. The adjusted fecundability ratio for the laboratory technicians was 0.94 [95% confidence interval (95% CI...

  4. Mutant frequency of radiotherapy technicians appears to be associated with recent dose of ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Messing, K.; Ferraris, J.; Bradley, W.E.; Swartz, J.; Seifert, A.M. (Universite du Quebec a Montreal (Canada))

    1989-10-01

    The frequency of hypoxanthine phosphoribosyl transferase (HPRT) mutants among peripheral T-lymphocytes of radiotherapy technicians primarily exposed to 60Co was measured by the T-cell cloning method. Mutant frequencies of these technicians in 1984 and 1986 were significantly higher than those of physiotherapy technicians who worked in a neighboring service, and correlated significantly with thermoluminescence dosimeter readings recorded during the 6 mo preceding mutant frequency determination. Correlations decreased when related to dose recorded over longer time intervals. HPRT mutant frequency determination in peripheral lymphocytes is a good measure of recently received biologically effective radiation dose in an occupationally exposed population.

  5. Mutant frequency of radiotherapy technicians appears to be associated with recent dose of ionizing radiation

    International Nuclear Information System (INIS)

    Messing, K.; Ferraris, J.; Bradley, W.E.; Swartz, J.; Seifert, A.M.

    1989-01-01

    The frequency of hypoxanthine phosphoribosyl transferase (HPRT) mutants among peripheral T-lymphocytes of radiotherapy technicians primarily exposed to 60Co was measured by the T-cell cloning method. Mutant frequencies of these technicians in 1984 and 1986 were significantly higher than those of physiotherapy technicians who worked in a neighboring service, and correlated significantly with thermoluminescence dosimeter readings recorded during the 6 mo preceding mutant frequency determination. Correlations decreased when related to dose recorded over longer time intervals. HPRT mutant frequency determination in peripheral lymphocytes is a good measure of recently received biologically effective radiation dose in an occupationally exposed population

  6. 40 CFR 82.40 - Technician training and certification.

    Science.gov (United States)

    2010-07-01

    ... speaking technicians by providing tests in other languages or allowing the use of a translator when taking the test. If a translator is used, the certificate received must indicate that translator assistance.... Each program must provide adequate training, through one or more of the following means: on-the-job...

  7. An Integration of Math with Auto Technician Courses

    Science.gov (United States)

    Valenzuela, Hector

    2012-01-01

    This article describes the development of the contextualized math, the course design, student teaching and daily interaction with the students, and the implementation aspects of the research project designed to develop contextualized mathematics and integrate it into the Auto Technician courses. The applied math curriculum was integrated into…

  8. Medication reconciliation and prescribing reviews by pharmacy technicians in a geriatric ward

    DEFF Research Database (Denmark)

    Buck, Thomas Croft; Gronkjaer, Louise Smed; Duckert, Marie-Louise

    2013-01-01

    OBJECTIVE: Incomplete medication histories obtained on hospital admission are responsible for more than 25% of prescribing errors. This study aimed to evaluate whether pharmacy technicians can assist hospital physicians' in obtaining medication histories by performing medication reconciliation an...... reconciliation and focused medication reviews. Further randomized, controlled studies including a larger number of patients are required to elucidate whether these observations are of significance and of importance for securing patient safety....... and prescribing reviews. A secondary aim was to evaluate whether the interventions made by pharmacy technicians could reduce the time spent by the nurses on administration of medications to the patients. METHODS: This observational study was conducted over a 7 week period in the geriatric ward at Odense...... University Hospital, Denmark. Two pharmacy technicians conducted medication reconciliation and prescribing reviews at the time of patients' admission to the ward. The reviews were conducted according to standard operating procedures developed by a clinical pharmacist and approved by the Head of the Geriatric...

  9. 20 CFR 1002.306 - Is a National Guard civilian technician considered a State or Federal employee for purposes of...

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Is a National Guard civilian technician... a National Guard civilian technician considered a State or Federal employee for purposes of USERRA? A National Guard civilian technician is considered a State employee for USERRA purposes, although he...

  10. Technician Marshall MacCready installs solar cells on the Helios Prototype

    Science.gov (United States)

    2000-01-01

    Technician Marshall MacCready carefully lays a panel of solar cells into place on a wing section of the Helios Prototype flying wing at AeroVironment's Design Development Center in Simi Valley, California. The bi-facial cells, manufactured by SunPower, Inc., of Sunnyvale, California, are among 64,000 solar cells which have been installed on the solar-powered aircraft to provide electricity to its 14 motors and operating systems. Developed by AeroVironment under NASA's Environmental Research Aircraft and Sensor Technology (ERAST) project, the Helios Prototype is the forerunner of a planned fleet of slow-flying, long duration, high-altitude aircraft which can perform atmospheric science missions and serve as telecommunications relay platforms in the stratosphere. Target goals set by NASA for the giant 246-foot span flying wing include reaching and sustaining subsonic horizontal flight at 100,000 feet altitude in 2001, and sustained continuous flight for at least four days and nights above 50,000 feet altitude 2003 with the aid of a regenerative fuel cell-based energy storage system now being developed.

  11. Effect of dental technician disparities on the 3-dimensional accuracy of definitive casts.

    Science.gov (United States)

    Emir, Faruk; Piskin, Bulent; Sipahi, Cumhur

    2017-03-01

    Studies that evaluated the effect of dental technician disparities on the accuracy of presectioned and postsectioned definitive casts are lacking. The purpose of this in vitro study was to evaluate the accuracy of presectioned and postsectioned definitive casts fabricated by different dental technicians by using a 3-dimensional computer-aided measurement method. An arch-shaped metal master model consisting of 5 abutments resembling prepared mandibular incisors, canines, and first molars and with a 6-degree total angle of convergence was designed and fabricated by computer-aided design and computer-aided manufacturing (CAD-CAM) technology. Complete arch impressions were made (N=110) from the master model, using polyvinyl siloxane (PVS) and delivered to 11 dental technicians. Each technician fabricated 10 definitive casts with dental stone, and the obtained casts were numbered. All casts were sectioned, and removable dies were obtained. The master model and the presectioned and postsectioned definitive casts were digitized with an extraoral scanner, and the virtual master model and virtual presectioned and postsectioned definitive casts were obtained. All definitive casts were compared with the master model by using computer-aided measurements, and the 3-dimensional accuracy of the definitive casts was determined with best fit alignment and represented in color-coded maps. Differences were analyzed using univariate analyses of variance, and the Tukey honest significant differences post hoc tests were used for multiple comparisons (α=.05). The accuracy of presectioned and postsectioned definitive casts was significantly affected by dental technician disparities (Ptechnician differences. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  12. Compensation of Emergency Medical Technician (EMT)-Basics and Paramedics.

    Science.gov (United States)

    Studnek, Jonathan R

    2016-12-01

    The objective of this paper is to identify factors associated with compensation for Emergency Medical Technician (EMT)-Basics and Paramedics and assess whether these associations have changed over the period 1999-2008. Data obtained from the Longitudinal EMT Attributes and Demographic Study (LEADS) surveys, a mail survey of a random, stratified sample of nationally certified EMT-Basics and Paramedics, were analyzed. For the 1999-2003 period, analyses included all respondents providing Emergency Medical Services (EMS). With the addition of a survey in 2004 about volunteers, it was possible to exclude volunteers from these analyses. Over 60% of EMT-Basics reported being either compensated or noncompensated volunteers in the 2004-2008 period. This was substantially and significantly greater than the proportion of EMT-Paramedic volunteers (Technician (EMT)-Basics and Paramedics. Prehosp Disaster Med. 2016;31(Suppl. 1):s87-s95.

  13. Combining BMI stimulation and mathematical modeling for acute stroke recovery and neural repair

    Directory of Open Access Journals (Sweden)

    Sara L Gonzalez Andino

    2011-07-01

    Full Text Available Rehabilitation is a neural plasticity-exploiting approach that forces undamaged neural circuits to undertake the functionality of other circuits damaged by stroke. It aims to partial restoration of the neural functions by circuit remodeling rather than by the regeneration of damaged circuits. The core hypothesis of the present paper is that - in stroke - Brain Machine Interfaces can be designed to target neural repair instead of rehabilitation. To support this hypothesis we first review existing evidence on the role of endogenous or externally applied electric fields on all processes involved in CNS repair. We then describe our own results to illustrate the neuroprotective and neuroregenerative effects of BMI- electrical stimulation on sensory deprivation-related degenerative processes of the CNS. Finally, we discuss three of the crucial issues involved in the design of neural repair-oriented BMIs: when to stimulate, where to stimulate and - the particularly important but unsolved issue of - how to stimulate. We argue that optimal parameters for the electrical stimulation can be determined from studying and modeling the dynamics of the electric fields that naturally emerge at the central and peripheral nervous system during spontaneous healing in both, experimental animals and human patients. We conclude that a closed-loop BMI that defines the optimal stimulation parameters from a priori developed experimental models of the dynamics of spontaneous repair and the on-line monitoring of neural activity might place BMIs as an alternative or complement to stem-cell transplantation or pharmacological approaches, intensively pursued nowadays.

  14. Students as Technicians: Screening Newborns for Cystic Fibrosis

    Science.gov (United States)

    Gusky, Sharon

    2014-01-01

    In this activity, freshman college students learn biotechnology techniques while playing the role of a laboratory technician. They perform simulations of three diagnostic tests used to screen newborns for cystic fibrosis. By performing an ELISA, a PCR analysis, and a conductivity test, students learn how biotechnology techniques can be used to…

  15. Are further education opportunities for emergency care technicians ...

    African Journals Online (AJOL)

    Background. A recent review of emergency care education and training in South Africa resulted in the creation of a new 2-year, 240-credit National Qualifications Framework (NQF) level 6 Emergency Care Technician (ECT) qualification. The National Department of Health (NDoH) view ECTs as 'mid-level workers' in the ...

  16. Carpal tunnel syndrome among laboratory technicians in relation to personal and ergonomic factors at work.

    Science.gov (United States)

    El-Helaly, Mohamed; Balkhy, Hanan H; Vallenius, Laura

    2017-11-25

    Work-related carpal tunnel syndrome (CTS) has been reported in different occupations, including laboratory technicians, so this study was carried out to determine the prevalence and the associated personal and ergonomic factors for CTS among laboratory technicians. A cross-sectional study was conducted among 279 laboratory technicians at King Fahd Hospital, Saudi Arabia, who filled in a self-administered questionnaire, including questions regarding their demographic criteria, occupational history, job tasks, workplace tools, ergonomic factors at work, and symptoms suggestive of CTS. Physical examinations and electrodiagnostic studies were carried out for those who had symptoms suggestive of CTS to confirm the diagnosis. Univariate and multivariate analysis were performed for both personal and physical factors in association with confirmed CTS among laboratory technicians. The prevalence of CTS among the laboratory technicians was 9.7% (27/279). The following were the statistically significant risk factors for CTS among them: gender (all cases of CTS were female, P=0.00), arm/hand exertion (OR: 7.96; 95% CI: 1.84-34.33), pipetting (OR: 7.27; 95% CI: 3.15-16.78), repetitive tasks (OR: 4.60; 95% CI: 1.39-15.70), using unadjustable chairs or desks (OR: 3.35; 95% CI: 1.23-9.15), and working with a biosafety cabinet (OR: 2.49; 95% CI: 1.11-5.59). CTS cases had significant longer work duration (17.9 ± 5.6 years) than CTS non-case (11.5 ± 7.4 yeas) with low OR (1.108). This study demonstrates some personal and ergonomic factors associated with CTS among the laboratory technicians, including female gender, arm/hand exertion, pipetting, repetitive tasks, working with a biosafety cabinet, and an unadjusted workstation.

  17. Nuclear instrument technician training

    International Nuclear Information System (INIS)

    Wollesen, E.S.

    1991-01-01

    This paper reports on Nuclear Instrument Technician (NIT) training that has developed at an accelerated rate over the past three decades. During the 1960's commercial nuclear power plants were in their infancy. For that reason, there is little wonder that NIT training had little structure and little creditability. NIT training, in many early plants, was little more than On-The Job Training (OJT). The seventies brought changes in Instrumentation and Controls as well as emphasis on the requirements for more in depth training and documentation. As in the seventies, the eighties saw not only changes in technologies but tighter requirements, standardized training and the development of accredited Nuclear Instrument Training; thus the conclusion: Nuclear Instrument Training Isn't What It Used To Be

  18. Discount factor in planning decision of electric sector

    International Nuclear Information System (INIS)

    Becker, J.L.; Maurer, L.T.A.

    1990-01-01

    Researchers and technicians have been giving a lot of attention to the issue of discount factor in planning in the electric sector. In this paper we review the most important points under consideration, attempting to broaden the discussion and stimulate the creativity of the technicians involved with the sector. There appears to be an emerging consensus that the discount factor to be used must consider the capital costs associated with the main financial sources utilized. The traditional factor of 10% per year must be re-evaluated and augmented, in order to best reflect long range economical and financial conditions. The paper emphasizes the importance of the discount factor to several decisions made within the sector, including energy conservation. Because of the relevance of the topic to Brazil future, we strongly suggest the utilization of sensitivity analysis techniques. (author)

  19. Guidelines for training and qualification of radiological protection technicians

    International Nuclear Information System (INIS)

    1987-08-01

    These guidelines, used in combination with plant-specific job analysis, provide the framework for a training and qualification program for radiological protection technicians at nuclear power plants. Radiological protection technicians are defined as those individuals, both plant and contractor, who will be engaged in the evaluation of radiological conditions in the nuclear plant and the implementation of the necessary radiological safety measures as they apply to nuclear plant workers and members of the general public. An important aspect of this work is recognizing and handling unusual situations involving radioactivity, including incidents related to degraded core conditions. These guidelines incorporate the results of an industry-wide job analysis and task analysis (JTA) combined with industry operating experience review. However, the industry-wide analyses did not identify all important academic and fundamental knowledge and skills. Further in-depth analysis by subject matter experts produced additional knowledge and skills that were added to these guidelines. All utilities should use these guidelines in conjunction with plant-specific and industry-wide JTA results to develop or validate their radiological protection technician training program. Plant-specific information should be used to establish appropriate training program content. This plant-specific information should reflect unique job duties, equipment, operating experience, and trainee entry-level qualifications. Revisions to these guidelines should be reviewed for applicability and incorporated into the training program using each utility's training system development (TSD) procedures. Plant-specific job analysis and task analysis data is essential to the development of performance-based training programs. These analyses are particularly useful in selecting tasks for training and in developing on-the-job training (OJT), laboratory training, and mock-up training. Qualification programs based on these

  20. A method for the efficient and effective evaluation of contract health physics technicians

    International Nuclear Information System (INIS)

    Burkdoll, S.C.; Conley, T.A.

    1992-01-01

    This paper reports that Wolf Creek has developed a method for efficiently training contract health physics technicians. The time allotted for training contractors prior to a refueling and maintenance outage is normally limited to a few days. Therefore, it was necessary to develop a systematic method to evaluate prior experience as well as practical skills and knowledge. In addition, instruction in the particular methodologies used at Wolf Creek hadto be included with methods for evaluating technician comprehension

  1. Characterization of Low Back Pain in Pilots and Maintenance Technicians on a Commercial Airline.

    Science.gov (United States)

    Fajardo Rodriguez, Hugo A; Ortiz Mayorga, Viviana A

    2016-09-01

    Lower back pain (LBP) is the most common complaint worldwide and the leading cause of disability in the workplace. In Colombia there are no epidemiological data on low back pain in aviation. This study aimed to characterize lower back pain in pilots and maintenance technicians in a Colombian commercial airline. Information was collected from the total population in a Colombian commercial airline in Bogota during the period from 2011 to 2013 using a voluntary survey which requested demographics, occupational (LEST survey) factors, back pain, and chronic pain (chronic pain grade scale). The prevalence rate of LBP in pilot respondents was 71% and the factors associated previously have belonged to the military forces: occupational exposure to physical load and work time. Chronic low back pain was at a prevalence of 49%. The prevalence of LBP in maintenance technicians was 65%. Associated factors were again similar to military forces and included mental workload. Chronic pain had a prevalence of 65%. Factors associated with chronic low back pain were the technicians' time in office and physical load. The prevalence of lower back pain in pilots is similar to that presented in the airline world population. In the case of maintenance technicians, the prevalence was higher than those found in other similar groups, but very similar to prevalences presented in different business industries, including the transport sector. Fajardo Rodriguez HA, Ortiz Mayorga VA. Characterization of low back pain in pilots and maintenance technicians on a commercial airline. Aerosp Med Hum Perform. 2016; 87(9):795-799.

  2. Survey to assess the role of pharmacy technicians and nonpharmacist staff in the operation of research pharmacies.

    Science.gov (United States)

    Siden, Rivka; Tamer, Helen R; Skyles, Amy J; Dolan, Christopher S; Propes, Denise J; Redic, Kimberly

    2014-11-01

    Results of a survey assessing trends and innovations in the use of pharmacy technicians and other nonpharmacist staff in the research pharmacy setting are reported. A Web-based survey was distributed to Internet communities of members of the American Society of Health-System Pharmacists and the University Health-System Consortium involved in investigational drug research and related practice areas. The survey collected data on the characteristics of institutions with pharmacy department staff dedicated to such research activities and the participation of pharmacists, technicians, and other staff in key areas of research pharmacy operations. Survey responses from 51 institutions were included in the data analysis. Overall, the reported distribution of assigned responsibility for most evaluated research pharmacy tasks reflected traditional divisions of pharmacist and technician duties, with technicians performing tasks subject to a pharmacist check or pharmacists completing tasks alone. However, some institutions reported allowing technicians to perform a number of key tasks without direct pharmacist supervision, primarily in the areas of inventory management and sponsor monitoring and auditing; almost half of the surveyed institutions reported technician involvement in teaching activities. In general, the reported use of "tech-check-tech" arrangements in research pharmacies was very limited. Some responding institutions reported the innovative use of nonpharmacist staff (e.g., paid interns, students and residents on rotation). Although the majority of research pharmacy tasks related to direct patient care are performed by or under the direct supervision of pharmacists, a variety of other essential tasks are typically assigned to pharmacy technicians and other nonpharmacist staff. Copyright © 2014 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  3. Home Electrical Safety Checklist

    Science.gov (United States)

    ... Interrupter Protection for Pools, Spas and Hot Tubs Metal Ladders and Electricity Don’t Mix Electrocution Hazard with Do-It-Yourself Repairs of Microwave Ovens Preventing Home Fires: Arc Fault Circuit Interrupters (AFCIs) Power up with ...

  4. Technician checks the mirrors of the Starshine-2 experiment

    Science.gov (United States)

    2001-01-01

    Technician checks the mirrors of the Starshine-2 experiment KSC-01PD-1715 KENNEDY SPACE CENTER, Fla. -- A technician checks the mirrors on the Starshine-2 experiment inside a canister in the payload bay of Space Shuttle Endeavour. The deployable experiment is being carried on mission STS-108. Starshine-2's 800 aluminum mirrors were polished by more than 25,000 students from 26 countries. Top priorities for the STS-108 (UF-1) mission of Endeavour are rotation of the International Space Station Expedition Three and Expedition Four crews, bringing water, equipment and supplies to the station in the Multi-Purpose Logistics Module Raffaello, and completion of robotics tasks and a spacewalk to install thermal blankets over two pieces of equipment at the bases of the Space Station's solar wings. Liftoff of Endeavour on mission STS-108 is scheduled for 7:41 p.m. EST.

  5. CERN's Technician Training Experience notches up another success!

    CERN Multimedia

    Stephanie Hills

    2015-01-01

    The programme was set up almost three years ago to help address a Europe-wide shortage of highly skilled technicians, with the participants gaining valuable skills and experience in an international environment. It’s clear that the programme works: some of the technician fellows who have taken part are being snapped up by major science projects and the high-tech industry.   Going underground: Fay Chicken at work in ATLAS. Fay Chicken (see UK news from CERN 59) has just accepted a job offer from the European Spallation Source in Sweden, where she will be working in the detector development team: “I’m also going to be setting up a new workshop where prototype detectors will be built. When I went to Lund, I was shown a big, empty room – it’s up to me to equip it!” This level of responsibility is a big step up for Fay, but there is no doubt that her time at CERN has both built her confidence to take on the role, and convinced ESS th...

  6. Development of a Training Program for Commercial Building Technicians

    Energy Technology Data Exchange (ETDEWEB)

    Rinholm, Rod

    2013-05-31

    This project focused on developing and deploying a comprehensive program of 22 training modules, including certification requirements, and accreditation standards for commercial building technicians, to help achieve the full savings potential of energy efficient buildings, equipment, and systems. This curriculum extended the currently available commercial building technician programs -- training a labor force in a growing market area focused on energy efficiency. The program helps to remove a major market impediment to low energy/zero energy commercial building system acceptance, namely a lack of operating personnel capable of handling more complex high efficiency systems. The project developed a training curriculum for commercial building technicians, with particular focus on high-efficiency building technology, and systems. In Phase 1, the project team worked collaboratively in developing a draft training syllabus to address project objectives. The team identified energy efficiency knowledge gaps in existing programs and plans and plans to address the gaps with either modified or new curricula. In Phase 2, appropriate training materials were developed to meet project objectives. This material was developed for alternative modes of delivery, including classroom lecture materials, e-learning elements, video segments, exercises, and hands-on training elements. A Certification and Accreditation Plan and a Commercialization and Sustainability Plan were also investigated and developed. The Project Management Plan was updated quarterly and provided direction on the management approaches used to accomplish the expected project objectives. GTI project management practices tightly coordinate project activities using management controls to deliver optimal customer value. The project management practices include clear scope definition, schedule/budget tracking, risk/issue resolution and team coordination.

  7. Results of the 2015 National Certified Pharmacy Technician Workforce Survey.

    Science.gov (United States)

    Desselle, Shane P; Holmes, Erin R

    2017-07-01

    The results of the 2015 National Certified Pharmacy Technician Workforce Survey are described. A survey was e-mailed to a randomized sample of 5,000 certified pharmacy technicians (CPhTs) throughout the United States, with response reminders employed. Survey items eliciting demographic and work characteristics and work life attitudes were generated from the literature and qualitative interviews. This study aimed to describe job satisfaction, sources of stress, profession and employer commitment, education and training, and reasons for entry into the profession among CPhTs and determine relationships between those variables and CPhTs' level of involvement in various work activities, with particular attention paid to differences in practice setting. Frequency statistics, correlation analysis, and means testing were used to meet study objectives and identify significant differences. A total of 516 CPhTs currently working as a pharmacy technician responded to the survey. The CPhTs reported high levels of involvement in more traditional activities but less involvement in those that involve greater cognitive load. Respondents reported moderate levels of job satisfaction and commitment and somewhat high levels of stress overall. Most CPhTs chose to be a pharmacy technician because they desired to enter a healthcare field and help people and were recruited. CPhTs derived benefit from all aspects of education and training evaluated and most from on-the-job training. Perceived value of education and training was associated with higher satisfaction and commitment and with lower stress. There were a number of differences in these work life attitudes across practice settings and by involvement in various job functions. The results of the survey indicated that job satisfaction and commitment were moderate and that stress levels were somewhat high among CPhTs. There were a number of differences in work life attitudes across practice settings and by involvement in various job

  8. Electrical. Teacher's Guide. Building Maintenance Units of Instruction.

    Science.gov (United States)

    East Texas State Univ., Commerce. Occupational Curriculum Lab.

    This teaching guide on electrical building maintenance, one in a series of six publications designed for building maintenance instructors in Texas, is designed to give students an understanding of electricity in order to know how to make basic repairs to the electrical systems in a building. Introductory material provides teachers with information…

  9. Changes in the ocular surface: initial observations from a pilot study of diagnostic radiology technicians (radiographers)

    International Nuclear Information System (INIS)

    Guerdal, Canan; Aydin, Sevda; Sengoer, Tomris; Onmus, Hale; Oezarar, Muemtaz

    2002-01-01

    The purpose of this study was to evaluate the clinical and cytological changes in the ocular surface of radiology technicians (radiographers) exposed to diagnostic doses of radiation. The Schirmer, Rose Bengal staining and Tear-Break-Up-Time tear function tests were carried out following routine ophthalmic examination in 15 radiology technicians (group I) and 15 controls (group II). Impression cytology was performed by placing 5-mm-thick half-circular cellulose acetate filter paper in the upper and lower quadrants around the limbus. The cytological evaluation was made using the mapping technique. Significantly increased dry eye was detected in group I. In the impression cytology investigation, squamous metaplasia and intraepithelial lymphocytic infiltration was noted in all the group-I cases. A distinct change was observed between the regions showing squamous metaplasia and neigbouring normal epithelial cell structure. Dry eye and ocular surface cytological changes were observed in diagnostic radiology technicians. Routine ophthalmic evaluation of radiology technicians would be beneficial in detecting early cytological changes and dry eye. (orig.)

  10. Electricity sector human resources review

    Energy Technology Data Exchange (ETDEWEB)

    Facette, J. [Canadian Association of Technicians and Technologists (Canada)

    2005-07-01

    The electricity industry is expanding, with new supply and infrastructure development equivalent to 35 per cent of existing capacity over the next 20 years. This paper examines the preliminary results of a human resources sector review providing industry specific labor force data. The key objectives of the review were to develop detailed industry profiles, identify root causes of human resources issues, identify industry best practices and develop a human resources strategy for the Canadian electricity sector. Estimates of current employment were provided, with age of employees, retirement projections, regional projections and estimated supply/demand gaps. Current shortages were identified, including wind energy technicians. The paper also identified a declining Canadian born labor force and a concurrent dependence on immigrants. A project research methodology was provided with a list of participating major employers. tabs., figs.

  11. Room Air Conditioners; Appliance Repair--Advanced: 9027.04.

    Science.gov (United States)

    Dade County Public Schools, Miami, FL.

    This Quinmester course includes installations, electrical and mechanical servicing, reverse cycle air conditioning, malfunctions, troubleshooting and repair, discharge, pump down, and recharging the system. The course may be taught as a two or three Quinmester credit course. In each instance the course consists of six instructional blocks:…

  12. Failure analyses and weld repair of boiler feed water pumps

    Energy Technology Data Exchange (ETDEWEB)

    Vulpen, R van [KemaPower Generation, Arnhem (Netherlands)

    1999-12-31

    During a regular inspection of the Boiler Auxiliaries at one of the Dutch Electricity Production Companies serious cracks were found in the cover and casings of the feed water circulation pumps in two units after 108.000 and 122.000 hours of boiler operation. Kema Laboratories carried out Failure analyses on boat samples at the cracked areas. Corrosion fatigue cracking was found on the inner side of the GS-24CrNiMo325 casing. Shop Weld repairs were carried out using a newly developed mechanized Plasma Welding Technique. The repaired feed water circulation pumps showed no problems alter several years of operation. The costs of repair were substantially lower than the costs of replacement. (orig.) 3 refs.

  13. Failure analyses and weld repair of boiler feed water pumps

    Energy Technology Data Exchange (ETDEWEB)

    Vulpen, R. van [KemaPower Generation, Arnhem (Netherlands)

    1998-12-31

    During a regular inspection of the Boiler Auxiliaries at one of the Dutch Electricity Production Companies serious cracks were found in the cover and casings of the feed water circulation pumps in two units after 108.000 and 122.000 hours of boiler operation. Kema Laboratories carried out Failure analyses on boat samples at the cracked areas. Corrosion fatigue cracking was found on the inner side of the GS-24CrNiMo325 casing. Shop Weld repairs were carried out using a newly developed mechanized Plasma Welding Technique. The repaired feed water circulation pumps showed no problems alter several years of operation. The costs of repair were substantially lower than the costs of replacement. (orig.) 3 refs.

  14. DOD Recovery personnel and NASA technicians inspect Friendship 7 spacecraft

    Science.gov (United States)

    1964-01-01

    Department of Defense Recovery personnel and spacecraft technicians from NASA adn McDonnell Aircraft Corp., inspect Astronaut John Glenn's Mercury spacecraft, Friendship 7, following its return to Cape Canaveral after recovery in the Atlantic Ocean.

  15. Technician Training for the Semiconductor Microdevices Industry. Final Report.

    Science.gov (United States)

    Center for Occupational Research and Development, Inc., Waco, TX.

    The Center for Occupational Research and Development (CORD) carried out four activities to foster semiconductor manufacturing technician (SMT) training: (1) collaboration with industry experts and educators while developing a curriculum to train SMTs; (2) implementation and testing of the curriculum at a technical college; (3) dissemination of…

  16. Dental technician pneumoconiosis mimicking lung cancer.

    Science.gov (United States)

    Uyar, Meral; Sokucu, Oral; Sanli, Maruf; Filiz, Ayten; Ali Ikidag, Mehmet; Feridun Isik, Ahmet; Bakir, Kemal

    2015-09-01

    A 47-year-old man was referred for assessment of bilateral lymph node enlargement identified on a routine chest radiograph. Positron emission tomography showed high standardized uptake values (SUVmax: 20.5) in right supraclavicular, right intercostal, and multiple mediastinal lymph nodes. Biopsy samples obtained from the right upper and left lower paratracheal nodes by mediastinoscopy revealed granulomatous inflammation. Clinical and laboratory findings indicated a diagnosis of dental technician pneumoconiosis. The patient is alive and well 3 years after diagnosis. This case highlights the importance of obtaining an occupational history.

  17. Mechanical technology for higher engineering technicians

    CERN Document Server

    Black, Peter

    1972-01-01

    Mechanical Technology for Higher Engineering Technicians deals with the mechanics of machines, thermodynamics, and mechanics of fluids. This book presents discussions and examples that deal with the strength of materials, technology of machines, and techniques used by professional engineers. The book explains the strain energy of torsion, coil springs, and the effects of axial load. The author also discusses the forces that produce bending, shearing, and bending combined with direct stress, as well as beams subjected to a uniform bending moment or simply supported beams with concentrated non-c

  18. Advances and results of the educative project: Implementation of the career of 'Technician in Radiological protection'

    International Nuclear Information System (INIS)

    Vizuet G, J.; Suarez, G.; Sanchez C, M.

    2003-01-01

    In this work the obtained advances and achievements during the impartment of the technician career in radiological protection are presented. This is carried out in the 'Justo Sierra' Technological High School Center of San Mateo Atenco, Estado de Mexico, and has for objective the formation of professional-technicians. (Author)

  19. A technician-delivered 'virtual clinic' for triaging low-risk glaucoma referrals.

    Science.gov (United States)

    Kotecha, A; Brookes, J; Foster, P J

    2017-06-01

    PurposeThe purpose of this study is to describe the outcomes of a technician-delivered glaucoma referral triaging service with 'virtual review' of resultant data by a consultant ophthalmologist.Patients and methodsThe Glaucoma Screening Clinic reviewed new optometrist or GP-initiated glaucoma suspect referrals into a specialist ophthalmic hospital. Patients underwent testing by three ophthalmic technicians in a dedicated clinical facility. Data were reviewed at a different time and date by a consultant glaucoma ophthalmologist. Approximately 10% of discharged patients were reviewed in a face-to-face consultant-led clinic to examine the false-negative rate of the service.ResultsBetween 1 March 2014 and 31 March 2016, 1380 patients were seen in the clinic. The number of patients discharged following consultant virtual review was 855 (62%). The positive predictive value of onward referrals was 84%. Three of the 82 patients brought back for face-to-face review were deemed to require treatment, equating to negative predictive value of 96%.ConclusionsOur technician-delivered glaucoma referral triaging clinic incorporates consultant 'virtual review' to provide a service model that significantly reduces the number of onward referrals into the glaucoma outpatient department. This model may be an alternative to departments where there are difficulties in implementing optometrist-led community-based referral refinement schemes.

  20. The enforcement order for the law for radiation and x-ray technicians engaging in medical treatment

    International Nuclear Information System (INIS)

    1984-01-01

    The enforcement order provides for the medical radiation technicians and medical X-ray technicians according to the established for them. The applicants for the license thereof must present their applications, together with the necessary documents, to the Government (or the prefectural government). The contents are as follows: application for license; to be entered in the register (with the items of the license); alteration of the registered items (the immediate corrective action, to the Government); elimination of the technicians from the register (to the Government); alteration of the license (the corrective action, to the Government); application for reissue of the license (to the Government); notification concerning the administrative measures. (Mori, K.)

  1. Phase Balancing by Means of Electric Vehicles Single-Phase Connection Shifting in a Low Voltage Danish Grid

    DEFF Research Database (Denmark)

    Lico, Pasqualino; Marinelli, Mattia; Knezovic, Katarina

    2015-01-01

    In Denmark, household consumers are supplied with three phase with neutral cable. In addition, the distribution service operator cannot decide to which phase electrical appliance are connected. The technician who realizes the installation connects the loads according to his technical expertise...

  2. Direct numerical simulation of noninvasive channel healing in electrical field

    KAUST Repository

    Wang, Yi; Sun, Shuyu

    2017-01-01

    Noninvasive channel healing is a new idea to repair the broken pipe wall, using external electric fields to drive iron particles to the destination. The repair can be done in the normal operation of the pipe flow without any shutdown of the pipeline

  3. Annual report of the group for maintenance of electrical equipment

    International Nuclear Information System (INIS)

    Rajic, M.

    1965-01-01

    This report includes detailed description of repairs and revisions of the electrical equipment of the RA reactor which were done according to the annual plan during the periods when reactor was not operated. Unplanned repairs are part of this report as well [sr

  4. A System Approach to Navy Medical Education and Training. Appendix 11. Advanced General Duty Corpsman.

    Science.gov (United States)

    1974-08-31

    curricula based upon job analysis was implemented to a level of methodology determination. These methods and curriculum materials constituted a third...Technician 8495 Dermatology Technician 8496 Embalming Technician 8497 Medical Illustration Technician 8498 Medical Equipment Repair Technician 8703 DT...IGIVE MEDICATED BATH 11 IGIVE MASSAGE FOP RELAXATION (SEDATIVE MASSAGED 12 IGIVE MASSAGE TO REDUCE MUSCLE SPASM 13 1APPLY WET COMPRESSES/SOAKS/PACKS 14

  5. Effect of specific resistance training on forearm pain and work disability in industrial technicians: cluster randomised controlled trial

    DEFF Research Database (Denmark)

    Andersen, Lars Louis; Jakobsen, Markus D; Pedersen, Mogens Theisen

    2012-01-01

    To determine the effect of specific resistance training on forearm pain and work disability in industrial technicians.......To determine the effect of specific resistance training on forearm pain and work disability in industrial technicians....

  6. Academy of Nutrition and Dietetics: Scope of Practice for the Dietetic Technician, Registered.

    Science.gov (United States)

    2013-06-01

    The Scope of Practice for the Dietetic Technician, Registered provides standards and tools to guide competence in performing nutrition and dietetics practice. Composed of statutory and individual components, the DTR's scope of practice is determined by state statute and the DTR's education, training, credentialing, and demonstrated and documented competence in practice. The Scope of Practice for the Dietetic Technician, Registered reflects the Academy's position on the DTR scope of practice and the essential technical assistance role of the DTR in providing safe timely person-centered care for the delivery of quality food and nutrition services.

  7. Internet treatment for generalized anxiety disorder: a randomized controlled trial comparing clinician vs. technician assistance.

    Science.gov (United States)

    Robinson, Emma; Titov, Nickolai; Andrews, Gavin; McIntyre, Karen; Schwencke, Genevieve; Solley, Karen

    2010-06-03

    Internet-based cognitive behavioural therapy (iCBT) for generalized anxiety disorder (GAD) has been shown to be effective when guided by a clinician. The present study sought to replicate this finding, and determine whether support from a technician is as effective as guidance from a clinician. Randomized controlled non-inferiority trial comparing three groups: Clinician-assisted vs. technician-assisted vs. delayed treatment. Community-based volunteers applied to the VirtualClinic (www.virtualclinic.org.au) research program and 150 participants with GAD were randomized. Participants in the clinician- and technician-assisted groups received access to an iCBT program for GAD comprising six online lessons, weekly homework assignments, and weekly supportive contact over a treatment period of 10 weeks. Participants in the clinician-assisted group also received access to a moderated online discussion forum. The main outcome measures were the Penn State Worry Questionnaire (PSWQ) and the Generalized Anxiety Disorder-7 Item (GAD-7). Completion rates were high, and both treatment groups reduced scores on the PSWQ (ptechnician-assisted groups, respectively, and on the GAD-7 were 1.55 and 1.73, respectively. At 3 month follow-up participants in both treatment groups had sustained the gains made at post-treatment. Participants in the clinician-assisted group had made further gains on the PSWQ. Approximately 81 minutes of clinician time and 75 minutes of technician time were required per participant during the 10 week treatment program. Both clinician- and technician-assisted treatment resulted in large effect sizes and clinically significant improvements comparable to those associated with face-to-face treatment, while a delayed treatment/control group did not improve. These results provide support for large scale trials to determine the clinical effectiveness and acceptability of technician-assisted iCBT programs for GAD. This form of treatment has potential to increase the

  8. Accuracy of vision technicians in screening ocular pathology at rural vision centres of southern India.

    Science.gov (United States)

    Suram, Vasantha; Addepalli, Uday Kumar; Krishnaiah, Sannapaneni; Kovai, Vilas; Khanna, Rohit C

    2016-03-01

    There is paucity of data on the inter-observer agreement and diagnostic accuracy between a primary-care technician (vision technician) and an ophthalmologist. Hence, the current study was conducted to assess the accuracy of vision technicians, to screen potentially sight-threatening ocular conditions at rural vision centres of southern India and their agreement with an ophthalmologist. In July to August 2010, patients presenting to seven vision centres in Adilabad district (Andhra Pradesh) were selected and screened in a masked manner by seven vision technicians followed by an examination by a consultant ophthalmologist. Agreement was assessed between vision technicians and the ophthalmologist for screening of potential sight-threatening ocular conditions and decisions for referral. The ophthalmologist's findings were considered as the reference standard. Two hundred and seventy-nine patients were enrolled at seven vision centres with a mean age of 32.9 ± 21.8 years. Agreement for screening of ocular pathology was 0.82 (95 per cent CI, 0.8-0.83). There was excellent agreement for cataract (0.97; 95 per cent CI, 0.93-1), refractive error (0.98; 95 per cent CI, 0.96-1), corneal pathology (1.0; 95 per cent CI, 1.0-1.0) and other anterior segment pathology (0.95; 95 per cent CI, 0.9-1); the agreement was moderate to fair for detection of glaucoma suspects (0.43; 95 per cent CI, 0.28-0.60) and retinal pathology (0.39; 95 per cent CI, 0.14-0.63). Sensitivity for screening of anterior segment pathology was 94.6-100 per cent. There was a fair to moderate sensitivity for glaucoma suspect; 35.6 per cent (95 per cent CI, 21.9-51.2) and retinal pathology 26.3 per cent (95 per cent CI, 9.2-51.2). Specificity for screening of ocular pathology was 98.2 to 100 per cent. The kappa (κ) agreement for referral for any pathology was 0.82 (0.8-0.83) CONCLUSION: As there is good agreement between the vision technicians and the ophthalmologist for screening and referral of

  9. Multiple Learning Strategies Project. Small Engine Repair. Visually Impaired.

    Science.gov (United States)

    Foster, Don; And Others

    This instructional package designed for visually impaired students, focuses on the vocational area of small engine repair. Contained in this document are forty learning modules organized into fourteen units: engine block; starters; fuel tank, lines, filters and pumps; carburetors; electrical; test equipment; motorcycle; machining; tune-ups; short…

  10. Automotive Manufacturing and Repair Technician Employment

    Science.gov (United States)

    McAlinden, Sean P.

    2013-01-01

    It's been more than three years since the U.S. automobile industry nearly collapsed. A controversial federal bailout, an increase in consumer demand, and a growing interest in environmentally friendly fuel-efficient vehicles and related technologies have combined to help create a remarkable recovery. Total U.S. sales of light vehicles in 2012 are…

  11. Considerations for services from dental technicians in fabrication of fixed prostheses: A survey of commercial dental laboratories in Thessaloniki, Greece.

    Science.gov (United States)

    Hatzikyriakos, Andreas; Petridis, Haralampos P; Tsiggos, Nikolaos; Sakelariou, Sotirios

    2006-11-01

    Effective communication and cooperation between dentists and dental technicians are essential in providing quality services. There has been a lack of information regarding dentist-dental technician communications and current methods and materials used for the fabrication of fixed partial dentures (FPDs). This cross-sectional study identified the materials and techniques used for fabrication of FPDs, as well as the status of communication between dentists and dental technicians in Thessaloniki, Greece. A questionnaire was developed with 7 sections pertaining to procedures and materials used for the fabrication of fixed prostheses: general questions, infection control, impressions/interocclusal records, die technique/mounting, information from final casts, prostheses design/materials, and communication/shade selection. The questionnaire was anonymous and distributed by the Association of Dental Technicians of Thessaloniki to all member laboratories (228) in the wider province of Thessaloniki, Greece. Due to the absence of normal distribution of the results, frequencies and medians were reported. Ninety-six of 228 dental laboratories responded (42.1% response rate). Twenty-six percent of dental laboratories did not routinely disinfect incoming items. The dental technicians considered 30% of incoming final impressions and 20% of interocclusal registrations as inadequate. Half of the time (55%) final casts were mounted by technicians on simple hinge articulators. Only 20% of tooth preparations had adequate finish lines. The majority (70%) of fixed restorations were metal-ceramic. Fifty-seven percent of dental technicians considered the delivery time requested by dentists as insufficient. The information provided in this study indicates areas of weakness in communication between dentists and dental technicians, along with areas where both parties should use greater care during clinical and laboratory procedures.

  12. The Technician beneath Our Wings, or Is That Blades?

    Science.gov (United States)

    Colony, Lee; Foster, John

    2011-01-01

    Today's trained technicians in alternative energy fields are finding even more career opportunities open to them as the United States and the world turn to green technology to power their homes and businesses. Wisconsin's Gateway Technical College is training workers for green collar careers in geoexchange heating and cooling systems, wind power…

  13. DNA repair , cell repair and radiosensitivity

    International Nuclear Information System (INIS)

    Zhestyanikov, V.D.

    1983-01-01

    Data obtained in laboratory of radiation cytology and literature data testifying to a considerable role of DNA repair in cell sensitivity to radiation and chemical DNA-tropic agents have been considered. Data pointing to the probability of contribution of inducible repair of DNA into plant cells sensitivity to X-rays are obtained. Certain violations of DNA repair do not result in the increase of radiosensitivity. It is assumed that in the cases unknown mechanisms of DNA repair operate

  14. Role of DNA repair in repair of cytogenetic damages. Slowly repaired DNA injuries involved in cytogenetic damages repair

    International Nuclear Information System (INIS)

    Zaichkina, S.I.; Rozanova, O.M.; Aptikaev, G.F.; Ganassi, E.Eh.

    1989-01-01

    Caffeine was used to study the kinetics of cytogenetic damages repair in Chinese hamster fibroblasts. Its half-time (90 min) was shown to correlate with that of repair of slowly repaired DNA damages. The caffeine-induced increase in the number of irreparable DNA damages, attributed to inhibition of double-strand break repair, is in a quantitative correlation with the effect of the cytogenetic damage modification

  15. Expectations and final evaluation of complete dentures by patients, dentist and dental technician.

    Science.gov (United States)

    Marachlioglou, C R M Z; Dos Santos, J F F; Cunha, V P P; Marchini, Leonardo

    2010-07-01

    There is a poor association between the dentist's evaluation of denture quality and patients' satisfaction with their dentures. Possible differences between dental professionals and patients' expectations might help explain differences in outcome evaluations. This study compared scores given by a dentist, a dental technician and patients for their expectations before and their final evaluation after complete dentures treatment. Twenty completely edentulous patients, a prosthodontist and a dental technician provided scores for the expected aesthetic and functional results of their dentures based on a visual analogue scale at baseline. Post-treatment completion ratings were given after adjustments, by dentist and patients. The dental technician provided post-treatment completion ratings after completing the dentures. The patients had higher expectations than the dental technician and the dentist perceived for both aesthetic and function (P < 0.001). The patients also presented higher post-treatment completion ratings than the dental professionals perceived for final aesthetics (P = 0.016, Kendall's W = 0.207) and function (P = 0.002, Kendall's W = 0.303). Only the dentist presented a statistically significant difference between expectations (lower) and final (higher) outcomes for aesthetics (P = 0.017) and function (P = 0.003). There was no correlation between expectations and post-treatment completion ratings according to the patients' age. There was also no correlation between the patients' gender and expectation scores. Patients presented higher expectations regarding their dentures than dental professionals. The dentist believed that dentures would bring fewer benefits than patients did, but his perception of denture benefits post-treatment was significantly higher than his expectations.

  16. Repair welding of cracked steam turbine blades

    International Nuclear Information System (INIS)

    Bhaduri, A.K.; Gill, T.P.S.; Albert, S.K.; Shanmugam, K.; Iyer, D.R.

    1999-01-01

    The procedure for repair welding of cracked steam turbine blades made of martensitic stainless steels has been developed using the gas tungsten arc welding process. Weld repair procedures were developed using both ER316L austenitic stainless steel filler wire and ER410 martensitic stainless steel filler wire. The repair welding procedure with austenitic filler wire was developed to avoid preheating of the blade as also hydrogen induced cold cracking, and involved evaluation of three different austenitic filler wires, viz. ER309L, ER316L and ERNiCr-3. The overall development of the repair welding procedure included selection of welding consumables (for austenitic filler metal), optimisation of post weld heat treatment parameters, selection of suitable method for local pre-heating and post-weld heat treatment (PWHT) of the blades, determination of mechanical properties of weldments in as-welded and PWHT conditions, and microstructural examination. After various trials using different procedures, the procedure of local PWHT using electrical resistance heating on the top surface of the weldment and monitoring the temperature by placing a thermocouple at the bottom of the weld, was found to give the most satisfactory results. A similar procedure was used for preheating while using ER410 filler metal. Mechanical testing of weldments before and after PWHT involved tensile tests at room temperature, face and root bend tests, and microhardness measurements across the fusion line and heat affected zone. During procedure qualification, mock-ups and actual repair welding, dye penetrant testing was used at different stages and where ever possible radiography was carried out. These procedures were developed for repair welding of cracked blades in the low-pressure (LP) steam turbines of Indian nuclear power plants. The procedure with ER316 L filler wire has so far been applied for repair welding of 2 cracked blades (made of AISI 410 SS) of LP steam turbines, while the procedure

  17. Mini Review: Biomaterials for Enhancing Neuronal Repair

    Science.gov (United States)

    Cangellaris, Olivia V.; Gillette, Martha U.

    2018-04-01

    As they differentiate from neuroblasts, nascent neurons become highly polarized and elongate. Neurons extend and elaborate fine and fragile cellular extensions that form circuits enabling long-distance communication and signal integration within the body. While other organ systems are developing, projections of differentiating neurons find paths to distant targets. Subsequent post-developmental neuronal damage is catastrophic because the cues for reinnervation are no longer active. Advances in biomaterials are enabling fabrication of micro-environments that encourage neuronal regrowth and restoration of function by recreating these developmental cues. This mini-review considers new materials that employ topographical, chemical, electrical, and/or mechanical cues for use in neuronal repair. Manipulating and integrating these elements in different combinations will generate new technologies to enhance neural repair.

  18. Appendices to the guidebook on the education and training of technicians for nuclear power

    International Nuclear Information System (INIS)

    1989-10-01

    The current publication, a supplement to the IAEA Guidebook on the Education and Training of Technicians for Nuclear Power, in conjunction with which it should be read, aims to assist Member States, especially the developing countries which are in the process of implementing, or intending to implement, a nuclear power programme, to understand and meet their requirements for qualified technicians in the most effective and efficient manner. It specifically seeks to assist policy makers and planners, as well as those designing and implementing education and training programmes. The Guidebook and this TECDOC complement the IAEA Guidebook on Manpower Development for Nuclear Power, as well as the IAEA Guidebook on the Qualification of Nuclear Power Plant Operations Personnel. This TECDOC supplements the Guidebook with valuable information on the national experience of IAEA Member States in the education and training of technicians for nuclear power, as well as examples of such education and training from various Member States. Figs and tabs

  19. Two technicians apply insulation to S-II second stage

    Science.gov (United States)

    1964-01-01

    Two technicians apply insulation to the outer surface of the S-II second stage booster for the Saturn V moon rocket. The towering 363-foot Saturn V was a multi-stage, multi-engine launch vehicle standing taller than the Statue of Liberty. Altogether, the Saturn V engines produced as much power as 85 Hoover Dams.

  20. Cooperative educational project for optical technicians utilizing amateur telescope making

    Science.gov (United States)

    Williamson, Ray

    2004-01-01

    In the modern optical shop, technicians are typically skilled machine operators who work on only one phase of the manufacture for each and every component. The product is designed, specified, methodized, scheduled and integrated by people off the shop floor. Even at the component level, the people inside the shop usually see only one stage of completion. In an effort to make the relevance of their work visible; to demonstrate competence to their peers; to gain appreciation for the work of others; and to give them a meaningful connection with the functions of optical systems, I created "The Telescope Project" for my former employer. I invited those interested to participate in an after-hours, partially subsidized project to build telescopes for themselves. The ground-rules included that we would all make the same design (thus practicing consensus and configuration management); that we would all work on every phase (thus learning from each other); and that we would obtain our parts by random lot at the end (thus making quality assurance a personal issue). In the process the participating technicians learned about optical theory, design, tolerancing, negotiation, scheduling, purchasing, fabrication, coating and assembly. They developed an appreciation for each other's contributions and a broader perspective on the consequences of their actions. In the end, each obtained a high-quality telescope for his or her personal use. Several developed an abiding love for astronomy. The project generated much interest from technicians who didn"t initially choose to participate. In this paper I describe the project in detail.

  1. DEGREE OF AWARENESS OF SOFT RELINING MATERIALS BY DENTAL TECHNICIANS

    Directory of Open Access Journals (Sweden)

    Ilian Hristov

    2017-10-01

    Full Text Available The aim of the current investigation is to analyze the dental-technicians’ awareness of the soft relining materials, their characteristics, advantages, shortcomings and methods for relining. Materials and methods: For the purpose of this investigation a standard questionnaire has been presented. A direct survey method, documentary and statistical method, as well as graphical methods, including tables, charts, graphics and figures, were used. Data were analysed with the help of IBM SPSS Statistics (ver. 19. Results: One hundred and eight dental technicians were included in the survey, evenly distributed by gender. Removable and fixed prosthodontics is the most commonly mentioned spheres of dental activities. Almost all included in the investigation point out the laboratory relining method as the most frequently used. Acrylic and silicone SRM are the most used groups of relining materials. Change of colour and hardness are the most frequently noticed shortcomings of these materials. The majority of the dental technicians declare that they have never done replacement of SRM or the relining has lasted more than a year. Discussion: The correlation between the age and the years of labour service among the participants is quite obvious. Most of them start working soon after their graduation. Removable prosthodontics is among the priorities for the majority of the labs. Conclusion: Although their unambiguous advantages, the soft relining materials have lots of shortcomings as well. The major problems are connected with their change of colour and hardness. Nevertheless, the dental technicians find them useful and reliable in overcoming specific prosthetic problems.

  2. Job analysis of nuclear power reactor health physics technicians

    International Nuclear Information System (INIS)

    Davis, L.T.; Mazour, T.J.; Clark, P.V.; Todd, R.C.; Marotta, F.J.

    1984-06-01

    This report describes a project, an industry-wide Job Analysis of Nuclear Power Reactor Health Physics Technicians (HPTs), conducted by Brookhaven National Laboratory and Analysis and Technology, Inc. to provide the industry with job-performance data that can be used in systematically defining training programs in terms of required job functions responsibilities, and performance standards. The job-analysis methodology is consistent with that used by the Institute of Nuclear Power Operations (INPO) in similar industry-wide projects and includes administration of over 850 job task questionnaires to utility and contractor Health Physics Technicians throughout the country. Data collected includes task performance (difficulty, importance, and frequency) and industry-wide demographics (job levels, experience, education, and training). The results of this project discussed herein include model job descriptions for HPT positions, summaries of HPT experience, education, and training, industry-wide task listings with task-performance characteristics, and recommendations of selected tasks as a basis for HPT training development. Finally, potential future applications of the data base by utility and contractor organizations in training program development and evaluation and personnel qualifications are discussed

  3. Cosmonaut Sergei Krikalev receives assistance from suit technician

    Science.gov (United States)

    1994-01-01

    Sergei Krikalev, alternative mission specialist for STS-63, gets help from Dawn Mays, a Boeing suit technician. The cosmonaut was about to participate in a training session at JSC's Weightless Environment Training Facility (WETF). Wearing the training version of the extravehicular mobility unit (EMU) space suit, weighted to allow neutral buoyancy in the 25 feet deep WETF pool, Krikalev minutes later was underwater simulating a contingency spacewalk, or extravehicular activity (EVA).

  4. Occupational contact dermatitis amongst dentists and dental technicians

    OpenAIRE

    Lugović-Mihić, Liborija; Ferček, Iva; Duvančić, Tomislav; Bulat, Vedrana; Ježovita, Josip; Novak-Bilić, Gaby; Šitum, Mirna

    2016-01-01

    Since the working medical personnel including dentists and dental technicians mainly use their hands, it is understandable that the most common occupational disease amongst medical personnel is contact dermatitis (CD) (80%-90% of cases). Development of occupational CD is caused by contact of the skin with various substances in occupational environment. Occupational etiologic factors for dental personnel are foremost reactions to gloves containing latex, followed by various dental materials...

  5. The relationship between managers' leadership styles and emergency medical technicians' job satisfaction.

    Science.gov (United States)

    Ghorbanian, Azimeh; Bahadori, Mohammadkarim; Nejati, Mostafa

    2012-01-01

    Leadership plays a crucial role in many professions, especially in challenging positions such as emergency medical service jobs. The purpose of this study was to explore the relationship between managers' leadership styles and emergency medical technicians' job satisfaction. This is a descriptive and cross-sectional study that was carried out in 2010. The research population included 21 managers and 87 emergency medical technicians working in 23 stations in Isfahan city, Iran. The main tools used for data accumulation were the Multiple Leadership Questionnaire for evaluating leadership styles and the Job Descriptive Index for measuring job satisfaction levels. Also, the Pearson correlation analysis test was used to evaluate the relationship between leadership style and job satisfaction. Among both managers and technicians, the highest mean score related to the transformational management style, whereas the lowest mean score related to the laissez-faire management style. Moreover, a significant relationship (Pleadership styles and job satisfaction. However, no significant relationship was observed between the laissez-faire management style and job satisfaction. Considering the importance of job satisfaction in medical emergencies, it is recommended that health sector policy makers should provide the groundwork for implementing the transformational leadership style to enhance job satisfaction of the medical emergency staff.

  6. Radiation protection technician job task analysis manual

    International Nuclear Information System (INIS)

    1990-03-01

    This manual was developed to assist all DOE contractors in the design and conduct of job task analysis (JTA) for the radiation protection technician. Experience throughout the nuclear industry and the DOE system has indicated that the quality and efficiency in conducting a JTA at most sites is greatly enhanced by using a generic task list for the position, and clearly written guidelines on the JTA process. This manual is designed to provide this information for personnel to use in developing and conducting site-specific JTAs. (VC)

  7. Performing Chest X-Rays at Inspiration in Uncooperative Children: The Effect of Exercises with a Training Program for Radiology Technicians

    International Nuclear Information System (INIS)

    Langen, H.J.; Sengenberger, C.; Bielmeier, J.; Jocher, R.; Kohlhauser-Vollmuth, Ch.; Eschmann, M.

    2014-01-01

    It is difficult to acquire a chest X-ray of a crying infant at maximum inspiration. A computer program was developed for technician training. Method. Video clips of 3 babies were used and the moment of deepest inspiration was determined in the single-frame view. 12 technicians simulated chest radiographs at normal video speed by pushing a button. The computer program stopped the video and calculated the period of time to the optimal instant for a chest X-ray. Demonstration software can be tested at website online. Every technician simulated 10 chest X-rays for each of the 3 video clips. The technicians then spent 40 minutes practicing performing chest X-rays at optimal inspiration. The test was repeated after 5, 20, and 40 minutes of practice. Results. 6 participants showed a significant improvement after exercises (collective 1). Deviation from the optimal instant for taking an X-ray at inspiration decreased from 0.39 to 0.22 s after 40 min of practice. 6 technicians showed no significant improvement (collective 2). Deviation decreased from a low starting value of 0.25 s to 0.21 s. Conclusion. The tested computer program improves the ability of radiology technicians to take a chest X-ray at optimal inspiration in a crying child

  8. [Position-checking by imaging embarked there tomotherapy and the delegation to the radiology technician].

    Science.gov (United States)

    Autret, A; Choupeaux, D; Le Mée, M

    2016-10-01

    Tomotherapy is a technique of IMRT and IGRT using a linear accelerator and a helical CT-scanner. To reach this targeting of precision, the repositioning of the patient is essential. The use of a contention adapted according to the location of the disease and the morphology of the patient is necessary for the safety of this one and the treatment. Once the patient positioned on the reference table, technicians of imager's team check by the acquisition of helical imagery with the reference CT-scanner the position of the patient, the zone of the PTV and healthy organs in the protected surroundings. At first, adjustment will be made automatically on three planes of the space (axial, sagittal, frontal) and three rotations (pitch, roll and yaw) by the device of treatment, then the technicians of imagery will bring a modification of these recalls manually. After validation, the processing will then be made in complete safety for the patient and the nursing. This check by MVCT is daily before every session of processing. It is made by the technicians of imagery. The radiation oncologist confirms the images at j0, then controls once a week MVCT. Traceability in the file of the patient of the various marks (osseous and\\or soft tissue) necessary for the daily gaps will be noted by this one to delegate to the technicians of imagery the validation of the MVCT before every session. Copyright © 2016. Published by Elsevier SAS.

  9. Large Outbreak of Hepatitis C Virus Associated With Drug Diversion by a Healthcare Technician.

    Science.gov (United States)

    Alroy-Preis, Sharon; Daly, Elizabeth R; Adamski, Christine; Dionne-Odom, Jodie; Talbot, Elizabeth A; Gao, Fengxiang; Cavallo, Steffany J; Hansen, Katrina; Mahoney, Jennifer C; Metcalf, Erin; Loring, Carol; Bean, Christine; Drobeniuc, Jan; Xia, Guo-Liang; Kamili, Saleem; Montero, José T

    2018-05-14

    In May 2012, the New Hampshire (NH) Division of Public Health Services (DPHS) was notified of 4 persons with newly diagnosed hepatitis C virus (HCV) infection at hospital X. Initial investigation suggested a common link to the hospital cardiac catheterization laboratory (CCL) because the infected persons included 3 CCL patients and a CCL technician. NH DPHS initiated an investigation to determine the source and control the outbreak. NH DPHS conducted site visits, case patient and employee interviews, medical record and medication use review, and employee and patient HCV testing using enzyme immunoassay for anti-HCV, reverse-transcription polymerase chain reaction for HCV RNA, nonstructural 5B (NS5B) and hypervariable region 1 (HVR1) sequencing, and quasispecies analysis. HCV HVR1 analysis of the first 4 cases confirmed a common source of infection. HCV testing identified 32 of 1074 CCL patients infected with the outbreak strain, including 3 patients coinfected with >1 HCV strain. The epidemiologic investigation revealed evidence of drug diversion by the HCV-infected technician, evidenced by gaps in controlled medication control, higher fentanyl use during procedures for confirmed cases, and building card key access records documenting the presence of the technician during days when transmission occurred. The employee's status as a traveling technician led to a multistate investigation, which identified additional cases at prior employment sites. This is the largest laboratory-confirmed drug diversion-associated HCV outbreak published to date. Recommendations to reduce drug diversion risk and to conduct outbreak investigations are provided.

  10. Requirements for, and training and certification of, quality assurance technicians for nuclear power plants

    International Nuclear Information System (INIS)

    Saiz, A.; Mir, A.; Serrano, J.

    1982-01-01

    The paper examines the requirements for, and training and certification of, technicians working in a quality assurance department at periods when the site, the main supplier and the engineering firm are being selected for construction, commissioning and operation of a light-water nuclear power plant with an output of approximately 1000 MW(e). In determining the system to be applied for the present work, account is taken of the special fields of engineering, supply, commissioning and operation. To this end, an analysis is made of the necessary organization, pointing out the number of technicians in each of the phases mentioned, and the necessary experience and knowledge required for discharging the functions indicated and for obtaining the appropriate certification. The second generation of Spanish nuclear power stations - about 7500MW(e) - demonstrated the need for quality assurance technicians. The Spanish Atomic Forum, a member of Foratom, is the first Spanish body to deal with the problem of training of such technicians at the national level through holding of seminars. This led to the appearance (in April 1974) of the first publication in Spanish on these techniques, a document which is still being used for teaching purposes. Later, it was the university and the professional associations which, with the support of the State Administration, undertook to provide this instruction. The paper also analyses Spanish experience in the teaching of quality assurance techniques during the period 1975-80, describing the programmes and contents of the courses

  11. Dynamic impact of brief electrical nerve stimulation on the neural immune axis-polarization of macrophages toward a pro-repair phenotype in demyelinated peripheral nerve.

    Science.gov (United States)

    McLean, Nikki A; Verge, Valerie M K

    2016-09-01

    Demyelinating peripheral nerves are infiltrated by cells of the monocyte lineage, including macrophages, which are highly plastic, existing on a continuum from pro-inflammatory M1 to pro-repair M2 phenotypic states. Whether one can therapeutically manipulate demyelinated peripheral nerves to promote a pro-repair M2 phenotype remains to be elucidated. We previously identified brief electrical nerve stimulation (ES) as therapeutically beneficial for remyelination, benefits which include accelerated clearance of macrophages, making us theorize that ES alters the local immune response. Thus, the impact of ES on the immune microenvironment in the zone of demyelination was examined. Adult male rat tibial nerves were focally demyelinated via 1% lysophosphatidyl choline (LPC) injection. Five days later, half underwent 1 hour 20 Hz sciatic nerve ES proximal to the LPC injection site. ES had a remarkable and significant impact, shifting the macrophage phenotype from predominantly pro-inflammatory/M1 toward a predominantly pro-repair/M2 one, as evidenced by an increased incidence of expression of M2-associated phenotypic markers in identified macrophages and a decrease in M1-associated marker expression. This was discernible at 3 days post-ES (8 days post-LPC) and continued at the 5 day post-ES (10 days post-LPC) time point examined. ES also affected chemokine (C-C motif) ligand 2 (CCL2; aka MCP-1) expression in a manner that correlated with increases and decreases in macrophage numbers observed in the demyelination zone. The data establish that briefly increasing neuronal activity favorably alters the immune microenvironment in demyelinated nerve, rapidly polarizing macrophages toward a pro-repair phenotype, a beneficial therapeutic concept that may extend to other pathologies. GLIA 2016;64:1546-1561. © 2016 Wiley Periodicals, Inc.

  12. Can preoperative electrical nociceptive stimulation predict acute pain after groin herniotomy?

    DEFF Research Database (Denmark)

    Aasvang, Eske Kvanner; Hansen, J.B.; Kehlet, H.

    2008-01-01

    Preoperative identification of patients at risk for high-intensity postoperative pain may be used to predict patients at risk for development of a persistent pain state and allocate patients to more intensive specific pain therapy. Preoperative pain threshold to electrocutaneus stimulation has...... repair. The correlation between the pain data for electrical stimulation was compared with the postoperative pain during the first week in 165 patients, whereof 3 were excluded. Preoperative electrical pain detection threshold and electrical pain tolerance threshold did not correlate to postoperative...... pain (rho = -0.13, P = .09, and rho = -1.2, P = .4, respectively. PERSPECTIVE: Although preoperative electrical nociceptive stimulation may predict patients at risk of high-intensity acute pain after other surgical procedures, this was not the case in groin hernia repair patients receiving concomitant...

  13. General Mechanical Repair. Minor Automotive Maintenance. Volume 1. Teacher's Guide.

    Science.gov (United States)

    East Texas State Univ., Commerce. Occupational Curriculum Lab.

    Fourteen units on minor automotive maintenance are presented in this teacher's guide. The units are the following: introduction to minor automotive maintenance, shop safety, engine principles, fuel system operation and repair, electrical system, ignition system, lubrication system, engine cooling system, exhaust system, wheel bearings and tires,…

  14. Snapshot of cobalt, chromium and nickel exposure in dental technicians.

    Science.gov (United States)

    Kettelarij, Jolinde; Nilsson, Sara; Midander, Klara; Lidén, Carola; Julander, Anneli

    2016-12-01

    It is not fully understood where and how people are exposed to sensitizing metals. Much can be learnt from studying occupational settings where metals are handled. To quantify cobalt (Co), chromium (Cr) and nickel (Ni) exposure on the skin and in the air, and urine levels, in dental technicians working with tools and alloys that may result in skin and respiratory exposure. The metal skin dose was quantified with acid wipe sampling in dental technicians (n = 13). Air exposure was monitored by personal air sampling. Spot urine samples were collected for 24 h. Metals were analysed with inductively coupled plasma mass spectrometry. Before work, Co was detected on the skin of 10 participants (0.00025-0.0039 µg/cm 2 ), and Cr (0.00051-0.011 µg/cm 2 ) and Ni (0.0062-0.15 µg/cm 2 ) on the skin of all participants. After a 2-h period without hand washing, CoCr-exposed participants had more Co on the skin (p = 0.004) than non-CoCr-exposed participants. Co was found in 10 air samples (0.22-155 µg/m 3 ), Cr in nine (0.43-71 µg/m 3 ), and Ni in four (0.48-3.7 µg/m 3 ). Metal urine concentrations were considered to be normal. Dental technicians were exposed to Co, Cr and Ni on the skin and through the air, which was not reflected in the urine concentrations in this study. Cobalt skin doses may potentially elicit allergic contact dermatitis and cause sensitization. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Role of DNA repair in repair of cytogenetic damages. Contribution of repair of single-strand DNA breaks to cytogenetic damages repair

    International Nuclear Information System (INIS)

    Rozanova, O.M.; Zaichkina, S.I.; Aptikaev, G.F.; Ganassi, E.Eh.

    1989-01-01

    The comparison was made between the results of the effect of poly(ADP-ribosylation) ingibitors (e.g. nicotinamide and 3-aminobenzamide) and a chromatin proteinase ingibitor, phenylmethylsulfonylfluoride, on the cytogenetic damages repair, by a micronuclear test, and DNA repair in Chinese hamster fibroblasts. The values of the repair half-periods (5-7 min for the cytogenetic damages and 5 min for the rapidly repaired DNA damages) and a similar modyfying effect with regard to radiation cytogenetic damages and kynetics of DNA damages repair were found to be close. This confirms the contribution of repair of DNA single-strand breaks in the initiation of structural damages to chromosomes

  16. DNA repair

    International Nuclear Information System (INIS)

    Setlow, R.

    1978-01-01

    Some topics discussed are as follows: difficulty in extrapolating data from E. coli to mammalian systems; mutations caused by UV-induced changes in DNA; mutants deficient in excision repair; other postreplication mechanisms; kinds of excision repair systems; detection of repair by biochemical or biophysical means; human mutants deficient in repair; mutagenic effects of UV on XP cells; and detection of UV-repair defects among XP individuals

  17. Exploring the impact of an automated prescription-filling device on community pharmacy technician workflow

    Science.gov (United States)

    Walsh, Kristin E.; Chui, Michelle Anne; Kieser, Mara A.; Williams, Staci M.; Sutter, Susan L.; Sutter, John G.

    2012-01-01

    Objective To explore community pharmacy technician workflow change after implementation of an automated robotic prescription-filling device. Methods At an independent community pharmacy in rural Mayville, WI, pharmacy technicians were observed before and 3 months after installation of an automated robotic prescription-filling device. The main outcome measures were sequences and timing of technician workflow steps, workflow interruptions, automation surprises, and workarounds. Results Of the 77 and 80 observations made before and 3 months after robot installation, respectively, 17 different workflow sequences were observed before installation and 38 after installation. Average prescription filling time was reduced by 40 seconds per prescription with use of the robot. Workflow interruptions per observation increased from 1.49 to 1.79 (P = 0.11), and workarounds increased from 10% to 36% after robot use. Conclusion Although automated prescription-filling devices can increase efficiency, workflow interruptions and workarounds may negate that efficiency. Assessing changes in workflow and sequencing of tasks that may result from the use of automation can help uncover opportunities for workflow policy and procedure redesign. PMID:21896459

  18. Variable speed electrical driving systems; Entrainements electriques a vitesse variable

    Energy Technology Data Exchange (ETDEWEB)

    Bonal, J. [ESE, Promethee, Groupe Schneider (France)

    1997-12-31

    This book is the first of a series of 3 volumes which synthesize the most recent knowledge on variable speed electrical driving systems. It is devoted to electronic and electromechanical engineers and technicians and to manufacturers of electrical equipments involving such systems. after a recall of basic electrotechnical and mechanical notions, this book focusses on the functionalities and criteria of definition of driving systems, and shows the interactions between the different parts of these equipments. It develops a methodological approach of the choice for the most suitable technology with respect to the application under consideration. Various industrial sectors are concerned and a particular attention is paid to the driving of receptive turbo-machineries which play a major role in the energy balance sheet of the industrial electrical power force. (J.S.) 28 refs.

  19. Repairing method and repairing device of incore structure

    International Nuclear Information System (INIS)

    Uraki, Keiichi; Okamura, Hisanobu; Matsumoto, Toshimi

    1998-01-01

    In structures or equipment made of stainless steel, Ni-based alloy or a low alloy steel and undergoing neutron irradiation and causing a crack-like defect in a reactor pressure vessel, a plate is applied to a region where the crack-like detect is caused, and pressure is applied locally to bond the plate by generated resistance. Namely, electric current is supplied to the portion to be bonded while pressurizing to bond it by generated resistance heat. Then the propagation of cracks can be prevented and occurrence of cracks upon repairing can be prevented relative to a structural member undergoing neutron irradiation in the reactor pressure vessel and causing a crack-like defect thereby enabling to provide effects of preventing occurrence of an accident due to stress corrosion cracking of a nuclear power plant and prolonging the integrity of the plant. (N.H.)

  20. Occupational Contact Dermatitis in Mechanics and Repairers Referred for Patch Testing: Retrospective Analysis From the North American Contact Dermatitis Group 1998-2014.

    Science.gov (United States)

    Warshaw, Erin M; Hagen, Solveig L; Sasseville, Denis; Maibach, Howard I; DeKoven, Joel G; Belsito, Donald V; Fowler, Joseph F; Zug, Kathryn A; Taylor, James S; Mathias, C G Toby; Fransway, Anthony F; DeLeo, Vincent A; Marks, James G; Pratt, Melanie D; Zirwas, Matthew J; Storrs, Frances J

    Contact dermatoses are common in mechanic and repair occupations. This study aimed to (1) estimate the prevalence of occupationally related contact dermatitis among mechanics/repairers patch tested from 1998 to 2014 by the North American Contact Dermatitis Group, (2) characterize responsible allergens and irritants, and their sources, and (3) compare results among 3 occupational subgroups (mechanics, electrical/electronic, and other). A cross-sectional analysis of patients patch tested by the North American Contact Dermatitis Group between 1998 and 2014. Of 38,784 patients patch tested, 691 (1.8%) were mechanics/repairers. Male sex (93.5%) and hand involvement (59.5%) were common overall. Occupationally related skin disease was more prevalent among vehicle and mobile equipment mechanics/repairers (52.7%) and other mechanics/repairers (41.4%) than electrical/electronic equipment mechanics/repairers (21.3%). Overall, carba mix, thiuram mix, and methylchloroisothiazolone/methylisothiazolone were the most common occupation-related clinically relevant allergens. Gloves, automotive vehicles, solvents, oils, lubricants, and fuels were the most common sources of responsible allergens. Common occupationally related allergens included rubber accelerators and the preservative methylchloroisothiazolone/methylisothiazolone.

  1. Weld repair issues in thick section austenitic pipework

    International Nuclear Information System (INIS)

    Goodwin, S.J.; Price, A.T.

    1989-03-01

    Thick section austenitic Type 316 Stainless steel, in the solution treated condition, has been used in Central Electricity Generating Board plant in the United Kingdom for some three decades and has given good service. Repair and replacement of this material after long term service is becoming a requirement and is complicated by the precipitation hardening and sensitisation of the materials. This paper summarises the compositional, microstructural and ageing characteristics of the wrought material and weld metals and the consequences for materials properties. Post weld heat treatment options are outlined and sensitisation to stress corrosion cracking is discussed. Finally, some examples of cracking that has occurred in plant after long term operation are given and weld repair research requirements are noted. (author)

  2. Mutations des roles techniques et formation. Etude documentaire (Changes in the Roles and Education of Technicians. Documentary Study).

    Science.gov (United States)

    Pinard, Helene

    Drawing from research conducted in 1990-91, this report examines trends affecting the future work of technicians in Quebec, their pre-employment education, and the link between college and work. Part 1 focuses on aspects of the economic, technological, and social environment that will influence the future role of technicians. Economic concerns…

  3. The validation of the Utrecht work engagement scale for emergency medical technicians in Gauteng

    Directory of Open Access Journals (Sweden)

    JLP Naudé

    2004-04-01

    Full Text Available The objectives of this study were to validate the Utrecht Work Engagement Scale (UWES for emergency medical technicians in the Gauteng Province of South Africa and to determine its construct equivalence and bias for different language groups. A cross-sectional survey design was used with a convenient sample (N = 318 of emergency medical technicians in Gauteng. The UWES and a biographical questionnaire were administered. A two-factor model of work engagement, consisting of Vigour/Dedication and Absorption was found. Exploratory factor analysis with target rotations confirmed the construct equivalence of the work engagement construct for white and black employees.

  4. Child Passenger Safety Technician Consultation in the Pediatric Primary Care Setting.

    Science.gov (United States)

    Burstein, Dina; Zonfrillo, Mark R; Baird, Janette; Mello, Michael J

    2017-09-01

    Correct use of a child safety seat (CSS) can reduce the risk of fatal motor vehicle crash-related injury by up to 71%; however, misuse rates for CSS are as high as 70%. We recruited 189 caregivers at 2 large suburban pediatric office practices; 94 in the intervention group and 95 in the control group. All participants completed a baseline survey and received a CSS safety brochure. Intervention participants had their CSS installation checked at enrollment by a certified child passenger safety (CPS) technician. Follow-up was conducted 4 months post enrollment. Intervention group participants had a 21.3% reduction in critical misuse at follow-up, whereas control participants critical misuse rate at follow-up was identical to the intervention group at baseline. A consult with a certified CPS technician, at the time of a routine visit to the pediatrician, resulted in a reduction in CSS misuse rates.

  5. Pedagogical Strategy for the professional training of technicians in Accountability and Auditing

    Directory of Open Access Journals (Sweden)

    Martha Ximena Jaramillo-Lema

    2016-06-01

    Full Text Available The professionals in the specialty of Accounting and Auditing have an important role in the founding of mid and small enterprises (PYMES, therefore, there is need of forming technicians of high quality. However, after the application of different methods of research, it has been proven that there are insufficiencies in their work, which has brought about that the hirers reject to employ them. They support their decision saying that these technicians lack professional preparation in the processes of accounting and auditing. The present article has as main purpose, to propose a pedagogical strategy for the development of updating and upbringing courses based on the development in the spheres of accounting and auditing , thus it has been designed a system of actions of marked pedagogical effect that allows the achievement of this objective.

  6. CrowdAidRepair: A Crowd-Aided Interactive Data Repairing Method

    KAUST Repository

    Zhou, Jian

    2016-03-25

    Data repairing aims at discovering and correcting erroneous data in databases. Traditional methods relying on predefined quality rules to detect the conflict between data may fail to choose the right way to fix the detected conflict. Recent efforts turn to use the power of crowd in data repairing, but the crowd power has its own drawbacks such as high human intervention cost and inevitable low efficiency. In this paper, we propose a crowd-aided interactive data repairing method which takes the advantages of both rule-based method and crowd-based method. Particularly, we investigate the interaction between crowd-based repairing and rule-based repairing, and show that by doing crowd-based repairing to a small portion of values, we can greatly improve the repairing quality of the rule-based repairing method. Although we prove that the optimal interaction scheme using the least number of values for crowd-based repairing to maximize the imputation recall is not feasible to be achieved, still, our proposed solution identifies an efficient scheme through investigating the inconsistencies and the dependencies between values in the repairing process. Our empirical study on three data collections demonstrates the high repairing quality of CrowdAidRepair, as well as the efficiency of the generated interaction scheme over baselines.

  7. Baseline job satisfaction and stress among pharmacists and pharmacy technicians participating in the Fleetwood Phase III Study.

    Science.gov (United States)

    Lapane, Kate L; Hughes, Carmel M

    2004-11-01

    To provide baseline levels of job satisfaction and stress among members of the long-term care pharmacy team participating in the Fleetwood Phase III evaluation. Cross-sectional design; long-term care pharmacy provider in North Carolina (the implementation site of the large-scale Fleetwood Phase III study). All current pharmacy employees as of May/June 2002. None. Health Professional Stress Inventory and job satisfaction. Ninety-four percent (16/17) of consultant pharmacists were satisfied with their job, with 89% reporting they would definitely choose to be a pharmacist again. Seventy-five percent both of dispensing pharmacists and pharmacy technicians reported overall job satisfaction. Forty-one reported that they would not choose to be a pharmacist (pharmacy technician) again. The most frequently reported sources of stress among the dispensing pharmacists and pharmacy technicians were conflicts with non-work obligations (i.e., family, personal life) and the ability to perform duties with short staffing. In addition, inadequate pay and few opportunities for job advancement were often/frequent sources of stress among pharmacy technicians. More than one third of dispensing pharmacists also reported stress frequently because of fears of mistakes in patient treatment. Overall, consultants are very satisfied with their positions, although dispensing pharmacists and pharmacy technicians are less satisfied with their work. The reasons may be because of the different nature of each job, as well as staffing shortages. The extent to which the Fleetwood Model can improve job satisfaction and impact on stress will be evaluated once we resurvey the pharmacy team after the intervention period of the Fleetwood Phase III study.

  8. Digitizing the Facebow: A Clinician/Technician Communication Tool.

    Science.gov (United States)

    Kalman, Les; Chrapka, Julia; Joseph, Yasmin

    2016-01-01

    Communication between the clinician and the technician has been an ongoing problem in dentistry. To improve the issue, a dental software application has been developed--the Virtual Facebow App. It is an alternative to the traditional analog facebow, used to orient the maxillary cast in mounting. Comparison data of the two methods indicated that the digitized virtual facebow provided increased efficiency in mounting, increased accuracy in occlusion, and lower cost. Occlusal accuracy, lab time, and total time were statistically significant (Ptechnician communication.

  9. Microprocessor based systems for the higher technician

    CERN Document Server

    Vears, RE

    2013-01-01

    Microprocessor Based Systems for the Higher Technician provides coverage of the BTEC level 4 unit in Microprocessor Based Systems (syllabus U80/674). This book is composed of 10 chapters and concentrates on the development of 8-bit microcontrollers specifically constructed around the Z80 microprocessor. The design cycle for the development of such a microprocessor based system and the use of a disk-based development system (MDS) as an aid to design are both described in detail. The book deals with the Control Program Monitor (CP/M) operating system and gives background information on file hand

  10. A case of hypersensitivity pneumonitis with giant cells in a female dental technician.

    Science.gov (United States)

    Kim, Yong-Hyun; Chung, Yun Kyung; Kim, Changhwan; Nam, Eun Suk; Kim, Hyun-Jun; Joo, Youngsu

    2013-10-04

    Dental technicians are exposed to methyl methacrylate(MMA) and hard metal dusts while working, and several cases of hypersensitivity pneumonitis caused by the exposure have been reported. The authors experienced a case of hypersensitivity pneumonitis in a female dental technician who had 10 years' work experience and report the case with clinical evidence. The patient's work, personal, social, and past and present medical histories were investigated based on patient questioning and medical records. Furthermore, the workplace conditions and tools and materials the patient worked with were also evaluated. Next, the pathophysiology and risk factors of pneumonitis were studied, and studies on the relationship between hypersensitivity pneumonitis and a dental technician's exposure to dust were reviewed. Any changes in the clinical course of her disease were noted for evaluation of the work-relatedness of the disease. The patient complained of cough and sputum for 1 year. In addition, while walking up the stairs, the patient was not able to ascend without resting due to dyspnea. She visited our emergency department due to epistaxis, and secondary hypertension was incidentally suspected. Laboratory tests including serologic, electrolyte, and endocrinologic tests and a simple chest radiograph showed no specific findings, but chest computed tomography revealed a centrilobular ground-glass pattern in both lung fields. A transbronchial biopsy was performed, and bronchoalveolar washing fluid was obtained. Among the findings of the laboratory tests, microcalcification, noncaseating granuloma containing foreign body-type giant cells, and metal particles within macrophages were identified histologically. Based on these results, hypersensitivity pneumonitis was diagnosed. The patient stopped working due to admission, and she completely quit her job within 2 months of restarting work due to reappearance of the symptoms. In this study, the patient did not have typical radiologic

  11. Historical overview of the process of training of Senior Technician in Nursing in relation to research training

    Directory of Open Access Journals (Sweden)

    Lola Rosario Altamirano-Baquerizo

    2016-07-01

    Full Text Available The formation of the Senior Technician in Nursing has been studied by many researchers as a process that integrates knowledge, skills and attitudes for the development of techniques and nursing procedures to healthy individuals or patients, families and community in the various bodies of the Network Asistencial. This paper identifies the training needs of Technician in Nursing, as it has found some shortcomings that do not refer to little curricular and methodological intent of the research training of this professional in the Bolivarian Technological Institute of Ecuador. In addressing the characterization of the historical background of the formation of the Senior Technician in Nursing el-logical historical method to use as documentation reviewing educational programs and policies of vocational training the technical level in the Ecuadorian higher education was used.

  12. Introducing a checking technician allows pharmacists to spend more time on patient-focused activities.

    Science.gov (United States)

    Napier, Patti; Norris, Pauline; Braund, Rhiannon

    2018-04-01

    Internationally there is an increasing focus on the clinical and cognitive services that pharmacists can provide. Lack of time has been identified as a barrier to pharmacists increasing their clinical activities. Within the pharmacy workplace there are many tasks that can only be performed by a pharmacist. The final accuracy check of a dispensed prescription is currently the sole responsibility of pharmacists in New Zealand. This takes up a significant amount of time during a pharmacist's work day. The introduction of a checking technician role has been suggested to allow pharmacists more time to do more patient focused work. To investigate the amount of time pharmacy staff spend on specific activities and to establish whether the introduction of a checking technician into twelve pilot sites increased the amount of time that the pharmacists could spend on patient focused activities. This study utilised a self-reported work sampling technique in twelve pilot sites, selected from both the hospital and community settings. Work sampling using an electronic device was conducted at two time-points (before the implementation of a Pharmacy Accuracy Checking Technician (PACT) role and when the PACT was in place). Data was collected at 10 min intervals for the period of five days, a working week. Tasks were grouped into patient focused, dispensing and personal activities. The introduction of the PACT into the pilot sites saw a mean increase of 19% in pharmacists' patient focused activities and a mean 20% decrease in dispensing activities. The introduction of a checking technician role into New Zealand pharmacies demonstrated the potential to provide pharmacists with more time to spend on patient focused activities. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Respiratory assessment of refractory ceramic fibers in a heating technician population.

    Science.gov (United States)

    Lucas, David; Clamagirand, Vincent; Capellmann, Pascale; Hervé, Agnès; Mauguen, Gilles; Le Mer, Yannik; Jegaden, Dominique

    2018-04-01

    Refractory ceramic fibers (RCF) have been extensively used for insulation in condensing boilers. The aim of this study was to evaluate the respiratory exposure to these fibers among maintenance heating technicians. We first created a working group (Carsat Brittany and Finistère Occupational Health Services) and carried out a sampling strategy. Atmospheric measurements were done during work tasks, and filters were analyzed by phase contrast microscopy (PCM) and scanning electron microscopy (SEM) in French approved laboratories. Four companies were included for a total of 15 days of work. During those 15 workdays, 12 SEM and 21 PCM samples were taken and analyzed. The phase contrast microscopy and SEM average results were 0.04 and 0.004 fibers/cm 3 , respectively. In conclusion, the study confirms heating technician RCF respiratory exposure during maintenance work for both condensation gas boilers and atmospheric boilers. Collective and individual prevention measures should be implemented along with appropriate medical follow-up.

  14. Evidence-based approach to the maintenance of laboratory and medical equipment in resource-poor settings.

    Science.gov (United States)

    Malkin, Robert; Keane, Allison

    2010-07-01

    Much of the laboratory and medical equipment in resource-poor settings is out-of-service. The most commonly cited reasons are (1) a lack of spare parts and (2) a lack of highly trained technicians. However, there is little data to support these hypotheses, or to generate evidence-based solutions to the problem. We studied 2,849 equipment-repair requests (of which 2,529 were out-of-service medical equipment) from 60 resource-poor hospitals located in 11 nations in Africa, Europe, Asia, and Central America. Each piece of equipment was analyzed by an engineer or an engineering student and a repair was attempted using only locally available materials. If the piece was placed back into service, we assumed that the engineer's problem analysis was correct. A total of 1,821 pieces of medical equipment were placed back into service, or 72%, without requiring the use of imported spare parts. Of those pieces repaired, 1,704 were sufficiently documented to determine what knowledge was required to place the equipment back into service. We found that six domains of knowledge were required to accomplish 99% of the repairs: electrical (18%), mechanical (18%), power supply (14%), plumbing (19%), motors (5%), and installation or user training (25%). A further analysis of the domains shows that 66% of the out-of-service equipment was placed back into service using only 107 skills covering basic knowledge in each domain; far less knowledge than that required of a biomedical engineer or biomedical engineering technician. We conclude that a great majority of laboratory and medical equipment can be put back into service without importing spare parts and using only basic knowledge. Capacity building in resource-poor settings should first focus on a limited set of knowledge; a body of knowledge that we call the biomedical technician's assistant (BTA). This data set suggests that a supported BTA could place 66% of the out-of-service laboratory and medical equipment in their hospital back

  15. Apparatus for enhancing tissue repair in mammals

    Science.gov (United States)

    Goodwin, Thomas J. (Inventor); Parker, Clayton R. (Inventor)

    2007-01-01

    An apparatus is disclosed for enhancing tissue repair in mammals, with the apparatus comprising: a sleeve for encircling a portion of a mammalian body part, said sleeve comprising an electrically conductive coil capable of generating an electromagnetic field when an electrical current is applied thereto, means for supporting the sleeve on the mammalian body part; and means for supplying the electrically conductive coil with a square wave time varying electrical current sufficient to create a time varying electromagnetic force of from approximately 0.05 gauss to 0.05 gauss within the interior of the coil in order that when the sleeve is placed on a mammalian body part and the time varying electromagnetic force of from approximately 0.05 gauss to 0.05 gauss is generated on the mammalian body part for an extended period of time, tissue regeneration within the mammalian body part is increased to a rate in excess of the normal tissue regeneration rate that would occur without application of the time varying electromagnetic force.

  16. Doses to nuclear technicians in a dedicated PET/CT centre utilising 18F fluorodeoxyglucose (FDG)

    International Nuclear Information System (INIS)

    Seierstad, T.; Stranden, E.; Bjering, K.; Evensen, M.; Holt, A.; Michalsen, H. M.; Wetteland, O.

    2007-01-01

    The first dedicated PET/CT centre in Norway was established at the Norwegian Radiumhospital in Oslo in 2005. Knowing that the introductions of PET-isotopes in nuclear medicine give increased occupational radiation dose to the technicians, a study was carried out in order to map the doses to staff members during different working operations and to see if any dose reducing measures were needed. The results of the study are in good agreement with other studies, and a technician dose of 20-25 nSv per injected MBq of 18 F seems to be representative for such centres. For an average injected activity of 350 MBq per patient, the dose limit is reached after handling around 3000 patients annually. For an annual number of less than 500 patients at the centre and rotation of the staff, an annual individual dose for the technicians would realistically be less than 2-3 mSv. Even a major increase in the number of patients will not result in individual doses near the ICRP dose limit. (authors)

  17. Medical Laboratory Technician--Hematology, Serology, Blood Banking, and Immunohematology (AFSC 90470).

    Science.gov (United States)

    Thompson, Joselyn H.

    This three-volume student text is designed for use by Air Force personnel enrolled in a self-study extension course for medical laboratory technicians. Covered in the individual volumes are hematology (the physiology of blood, complete blood counts and related studies, erythrocyte studies, leukocyte and thrombocyte maturation, and blood…

  18. Integrated Technical Information for the Air Logistics Center: Enhancing Maintenance Technician Task Performance

    National Research Council Canada - National Science Library

    Mitta, Deborah

    1998-01-01

    This technical paper documents the final results of an analysis of the task environment under which depot maintenance technicians perform their jobs--specifically, programmed depot maintenance (PDM) for F-15 aircraft...

  19. Spacecraft and propulsion technician error

    Science.gov (United States)

    Schultz, Daniel Clyde

    Commercial aviation and commercial space similarly launch, fly, and land passenger vehicles. Unlike aviation, the U.S. government has not established maintenance policies for commercial space. This study conducted a mixed methods review of 610 U.S. space launches from 1984 through 2011, which included 31 failures. An analysis of the failure causal factors showed that human error accounted for 76% of those failures, which included workmanship error accounting for 29% of the failures. With the imminent future of commercial space travel, the increased potential for the loss of human life demands that changes be made to the standardized procedures, training, and certification to reduce human error and failure rates. Several recommendations were made by this study to the FAA's Office of Commercial Space Transportation, space launch vehicle operators, and maintenance technician schools in an effort to increase the safety of the space transportation passengers.

  20. Severity of electrical accidents in the construction industry in Spain.

    Science.gov (United States)

    Suárez-Cebador, Manuel; Rubio-Romero, Juan Carlos; López-Arquillos, Antonio

    2014-02-01

    This paper analyzes the severity of workplace accidents involving electricity in the Spanish construction sector comprising 2,776 accidents from 2003 to 2008. The investigation considered the impact of 13 variables, classified into 5 categories: Personal, Business, Temporal, Material, and Spatial. The findings showed that electrical accidents are almost five times more likely to have serious consequences than the average accident in the sector and it also showed how the variables of age, occupation, company size, length of service, preventive measures, time of day, days of absence, physical activity, material agent, type of injury, body part injured, accident location, and type of location are related to the severity of the electrical accidents under consideration. The present situation makes it clear that greater effort needs to be made in training, monitoring, and signage to guarantee a safe working environment in relation to electrical hazards. This research enables safety technicians, companies, and government officials to identify priorities and to design training strategies to minimize the serious consequences of electrical accidents for construction workers. Copyright © 2013 Elsevier Ltd and National Safety Council. All rights reserved.

  1. Royal Engineer Geographic Technicians: Exploring their attitudes to education and training

    Science.gov (United States)

    Knight, John Anthony

    A creative approach is presented for understanding the attitudes of Royal Engineer (RE) Geographic Technicians (Geo Techs) to training and education. Through a grounded theory methodology, participants' experiences of learning and teaching are explored. These provide a greater awareness and perception of attitudes than have emerged through more established, formal methods of evaluating the effectiveness of training. Recent developments in technology, doctrine, requirements and operations have brought about significant changes to the range and complexity of subjects taught in the field of Geospatial Intelligence (GEOINT). This in turn has increased the challenges to RE staff and students, many of whom find themselves instructing on or undertaking demanding degree level courses without the requisite formal qualifications. Grounded theory, based on guidelines rather than rigid rules, is adopted to provide a study of RE Geographic Technicians' learning experiences from the perspective of those who live it and for an interpretive understanding of their meanings to emerge. The policies, culture and social processes in which the RE Geo training takes place are explored to appreciate the influence of the training environment on learning. Data obtained through focus groups held with students and instructors, and through in-depth interviews with individuals who hold key roles associated with the course, recognises the relativism of multiple social realities in developing a rich source of knowledge on attitudes to learning. The collection, synthesis and analysis of data led to the emergence of core categories: context, commitment, expectations, motivation, qualifications, relevance and respect. Through their engagement the research participants' awareness, in particular of instructors, of Geographic Technicians' attitudes to training and education has been raised. Using the theoretical framework of communities of practice, the challenges and effectiveness of the RSMS as a

  2. Animal Health Technicians: A Survey of Program Graduates and of Veterinarians.

    Science.gov (United States)

    Barsaleau, Richard B.; Walters, Henry R.

    This document compiles the reports of two surveys conducted by Cosumnes River College to determine the status of graduates of its Animal Health Technician program, and to assess the acceptance and use of such paraprofessionals by area veterinarians. Information concerning type of employment, state certification, salaries, types of duties, length…

  3. Hydraulics and pneumatics a technician's and engineer's guide

    CERN Document Server

    Parr, Andrew

    1991-01-01

    Hydraulics and Pneumatics: A Technician's and Engineer's Guide provides an introduction to the components and operation of a hydraulic or pneumatic system. This book discusses the main advantages and disadvantages of pneumatic or hydraulic systems.Organized into eight chapters, this book begins with an overview of industrial prime movers. This text then examines the three different types of positive displacement pump used in hydraulic systems, namely, gear pumps, vane pumps, and piston pumps. Other chapters consider the pressure in a hydraulic system, which can be quickly and easily controlled

  4. Apparatus and method for enhancing tissue repair in mammals

    Science.gov (United States)

    Goodwin, Thomas J. (Inventor); Parker, Clayton R. (Inventor)

    2009-01-01

    An apparatus is introduced for the use of enhancing tissue repair in mammals. The apparatus includes a sleeve; an electrically conductive coil; a sleeve support; an electrical circuit configured to supply the coil with a square wave time varying electrical current sufficient to create approximately 0.05 gauss to 0.5 gauss. When in use, the sleeve of the apparatus is placed on a mammalian body part and the time varying electromagnetic force of from approximately 0.05 gauss to 0.5 gauss is generated on the mammalian body for an extended period of time so that the tissue is encouraged to be regenerated in the mammalian body part at a rate in excess of the normal tissue regeneration rate relative to regeneration without application of the time varying electromagnetic force.

  5. The Hazardous Material Technician Apprenticeship Program at Lawrence Livermore National Laboratory

    International Nuclear Information System (INIS)

    Steiner, S.D.

    1987-07-01

    This document describes an apprenticeship training program for hazardous material technician. This entry-level category is achieved after approximately 216 hours of classroom and on-the-job training. Procedures for evaluating performance include in-class testing, use of on-the-job checks, and the assignment of an apprentice mentor for each trainee

  6. Studies on the chronological alterations of blood counts on the radiological technicians at health centers in Japan (1957 - 1975)

    International Nuclear Information System (INIS)

    Endo, Kouichi; Ishizaka, Masatsuna

    1977-01-01

    From the nine health surveys made on clinical radiation technicians working at health centers during the 18 years from 1957 to 1975, 679 technicians on whom blood examinations were made for not less than ten consecutive years were sampled to investigate for chronological alterations in their blood parameters. The radiation protective means at the health centers have made rapid progress ever since the atomic bomb experiment in 1954, and the dose of exposure to radiation then began to decrease. On the other hand, it was in about 1960 that the measurement of individual exposure doses began to be made on 60% of all the technicians. Chronological alterations in the average blood counts of these technicians under the abovementioned situation were such that RBC and hemoglobin level continued to increase from 1963 until about 1967, but then began to decrease, and that WBC was as low as 5,883/mm 3 in 1957, but tended to increase though slightly at each of the subsequent surveys, and was increased to 6,570/mm 3 in 1975, that is, WBC has been approaching the normal count of 6,774/mm 3 in the Japanese, with a significant difference at a not more than 1% level of significance in each survey year. For the purpose of preventing radiation hazard, further efforts should be made to protect the technicians from exposure to radiation and to control their health. (auth.)

  7. Integrating Safety in the Aviation System: Interdepartmental Training for Pilots and Maintenance Technicians

    Science.gov (United States)

    Mattson, Marifran; Petrin, Donald A.; Young, John P.

    2001-01-01

    The study of human factors has had a decisive impact on the aviation industry. However, the entire aviation system often is not considered in researching, training, and evaluating human factors issues especially with regard to safety. In both conceptual and practical terms, we argue for the proactive management of human error from both an individual and organizational systems perspective. The results of a multidisciplinary research project incorporating survey data from professional pilots and maintenance technicians and an exploratory study integrating students from relevant disciplines are reported. Survey findings suggest that latent safety errors may occur during the maintenance discrepancy reporting process because pilots and maintenance technicians do not effectively interact with one another. The importance of interdepartmental or cross-disciplinary training for decreasing these errors and increasing safety is discussed as a primary implication.

  8. THE POWER FACTOR IMPROVING OF THE MOTORS IN ENTERPRISES WITH REPAIR OF RAILWAY EQUIPMENT

    Directory of Open Access Journals (Sweden)

    O. L. Marenych

    2008-03-01

    Full Text Available In this article the following problem has been considered: ways of power factor increase for electric drives installed at the railway machinery repair enterprises with taking into account the specific conditions of technological processes.

  9. Institutional transparency improves public perception of lab animal technicians and support for animal research.

    Science.gov (United States)

    Mills, Katelyn E; Han, Zetta; Robbins, Jesse; Weary, Daniel M

    2018-01-01

    The use of animals in research is controversial and often takes place under a veil of secrecy. Lab animal technicians responsible for the care of animals at research institutions are sometimes described as performing 'dirty work' (i.e. professions that are viewed as morally tainted), and may be stigmatized by negative perceptions of their job. This study assessed if transparency affects public perceptions of lab animal technicians and support for animal research. Participants (n = 550) were randomly assigned to one of six scenarios (using a 3x2 design) that described identical research varying only the transparency of the facility (low, high) and the species used (mice, dogs, cows). Participants provided Likert-type and open-ended responses to questions about the personal characteristics (warmth, competence) of a hypothetical lab technician 'Cathy' and their support for the described research. Quantitative analysis showed participants in the low-transparency condition perceived Cathy to be less warm and were less supportive of the research regardless of animal species. Qualitative responses varied greatly, with some participants expressing support for both Cathy and the research. These results suggest that increasing transparency in lab animal institutions could result in a more positive perception of lab animal researchers and the work that they do.

  10. Evaluating the effectiveness of an online medical laboratory technician program.

    Science.gov (United States)

    Hansen-Suchy, Kara

    2011-01-01

    The purpose of this study was to analyze the effectiveness of an online medical laboratory technician program in the academic preparation and development of laboratory professionals. A semi-quantitative comparative research design was used. Several factors were considered in this evaluation. Academic outcomes between online and campus medical laboratory technician (MLT) students was determined by comparing overall and categorical scores on certification exams as well as first time pass rate. Certification exam scores and first time pass rates were also compared to national norms when possible to do so. Demographic data, including age and experience were compared. Additionally, learning styles were assessed to determine if there was a correlation to overall GPA and MLT GPA and if learning styles could be used to predict successful completion of an online Associates of Applied Science. The research was conducted at an academic university located in the mountain west United States. Participants consisted of online and campus students enrolled in a Medical Laboratory Technician program that graduated with their Associate of Applied Science degree between the years 2007-2009. Results of these years were also compared to graduates from 2004-2006 in the same program. Certification performance and first time pass rates were the major outcomes measured. Age and experience were correlated. Online learning styles and GPA were also compared to successful degree completion. The researcher found no significant difference in certification performance with regard to total and categorical scores, and first time pass rates between campus and online MLT students. Online students were slightly older and had more experience working in a laboratory in some capacity. Correlation studies showed significant positive correlation between learning styles, GPA, and successful completion of an Associate of Applied Science degree. When registry scores were compared to the prior cohort of online

  11. Rig Technician: Apprenticeship Course Outline. Apprenticeship and Industry Training. 5211.1

    Science.gov (United States)

    Alberta Advanced Education and Technology, 2011

    2011-01-01

    The graduate of the Rig Technician apprenticeship program is a certified journeyperson who will be able to: (1) take responsibility for personal safety and the safety of others; (2) supervise, coach and train apprentices and floor hands; (3) perform the duties of a motorhand, derrickhand or driller; and (4) perform assigned tasks in accordance…

  12. Repairable-conditionally repairable damage model based on dual Poisson processes.

    Science.gov (United States)

    Lind, B K; Persson, L M; Edgren, M R; Hedlöf, I; Brahme, A

    2003-09-01

    The advent of intensity-modulated radiation therapy makes it increasingly important to model the response accurately when large volumes of normal tissues are irradiated by controlled graded dose distributions aimed at maximizing tumor cure and minimizing normal tissue toxicity. The cell survival model proposed here is very useful and flexible for accurate description of the response of healthy tissues as well as tumors in classical and truly radiobiologically optimized radiation therapy. The repairable-conditionally repairable (RCR) model distinguishes between two different types of damage, namely the potentially repairable, which may also be lethal, i.e. if unrepaired or misrepaired, and the conditionally repairable, which may be repaired or may lead to apoptosis if it has not been repaired correctly. When potentially repairable damage is being repaired, for example by nonhomologous end joining, conditionally repairable damage may require in addition a high-fidelity correction by homologous repair. The induction of both types of damage is assumed to be described by Poisson statistics. The resultant cell survival expression has the unique ability to fit most experimental data well at low doses (the initial hypersensitive range), intermediate doses (on the shoulder of the survival curve), and high doses (on the quasi-exponential region of the survival curve). The complete Poisson expression can be approximated well by a simple bi-exponential cell survival expression, S(D) = e(-aD) + bDe(-cD), where the first term describes the survival of undamaged cells and the last term represents survival after complete repair of sublethal damage. The bi-exponential expression makes it easy to derive D(0), D(q), n and alpha, beta values to facilitate comparison with classical cell survival models.

  13. Job satisfaction, stress and burnout in anaesthetic technicians in New Zealand.

    Science.gov (United States)

    Kluger, M T; Bryant, J

    2008-03-01

    Anaesthetic technicians play a key role in the operating room, yet little is known about their levels of job satisfaction or workplace stress. A blinded, confidential single mail-out survey was posted to anaesthetic technicians in New Zealand. The survey consisted of demographic information, a job satisfaction survey, the Maslach Burnout Inventory and the Short Form 12. At total of 154 forms were returned (51% response rate). Respondents worked predominantly in public hospitals and many had duties outside the operating room. Job satisfaction was related to teamwork, practical nature of work and patient contact, while dissatisfaction was related to lack of respect from nurses and limited career pathway. High to moderate levels of emotional exhaustion (48%), depersonalisation (39%) and low levels of personal accomplishment (58%) were indicators of burnout. The Short Form 12 revealed high levels of physical impairment in 24% and emotional impairment in 35% of respondents. These data suggest that work is needed to evaluate anaesthetic assistants' job structure and actively manage their important physical and emotional sequelae.

  14. MRI-related magnetic field exposures and risk of commuting accidents - A cross-sectional survey among Dutch imaging technicians.

    Science.gov (United States)

    Huss, Anke; Schaap, Kristel; Kromhout, Hans

    2017-07-01

    Imaging technicians working with magnetic resonance imaging (MRI) may experience acute effects such as vertigo or dizziness when being exposed. A previous study also reported an increased risk of accidents in MRI exposed staff. We aimed at evaluating commuting accident risk in Dutch imaging technicians. Of invited imaging technicians, 490 (29%) filled in a questionnaire pertaining to (near) accidents when driving or riding a bike, health, lifestyle and work practices. We used logistic regression to evaluate the association between exposure to MRI-related electromagnetic fields and risk of commuting (near) accidents in the year prior to the survey, adjusted for a range of potential confounders. Our cross-sectional study indicated an increased risk of (near) accidents if imaging technicians had worked with MRI in the year prior to the survey (odds ratio OR 2.13, 95%CI 1.23-3.69). Risks were higher in persons who worked with MRI more often (OR 2.32, 95%CI 1.25-4.31) compared to persons who worked sometimes with MRI (OR 1.91, 95%CI 0.98-3.72), and higher in those who had likely experienced higher peak exposures to static and time-varying magnetic fields (OR 2.18, 95%CI 1.06-4.48). The effect was seen on commuting accidents that had occurred on the commute from home to work as well as accidents from work to home or elsewhere. Imaging technicians working with MRI scanners may be at an increased risk of commuting (near) accidents. This result needs confirmation and potential risks for other groups (volunteers, patients) should be investigated. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Tissue repair capacity and repair kinetics deduced from multifractionated or continuous irradiation regimens with incomplete repair

    International Nuclear Information System (INIS)

    Thames, H.D. Jr.; Peters, L.J.

    1984-01-01

    A model is proposed for cell survival after multiple doses, when the interfraction interval is insufficient for complete Elkind repair. In the limit of ever-increasing number of ever-smaller fractional doses, the model transforms into the accumulation model of survival after continuous irradiation. When adapted to describe tissue responses to isoeffective multifractionated regimens, wherein repair is incomplete, a generalization of the usually linear plot of reciprocal total dose versus dose per fraction is obtained, in which downward curvature is evident. There is an advantage in studying tissue responses to multifractionated regimens with incomplete repair in the interfraction intervals, or continuous exposures at various dose rates since, in addition to determination of repair capacity, there is an estimate of repair kinetics. Results of analyses of previously published data are presented as illustration. Estimated from the response of three acutely responding normal tissues in the mouse (jejunum, colon and bone marrow), repair halftimes ranged from 0.3-0.9 h and values of β/delta were approximately 0.1 Gy -1 . From the response of mouse lung (LD50 for pneumonitis) to multifractionated regimens with incomplete repair, the repair halftime was estimated at 1.5 h and β/delta was 0.27 Gy -1 . In the rat spinal cord β/delta was 0.7 Gy -1 and Tsub(1/2) was 1.5 h. (U.K.)

  16. Comparing Biomechanical Properties, Repair Times, and Value of Common Core Flexor Tendon Repairs.

    Science.gov (United States)

    Chauhan, Aakash; Schimoler, Patrick; Miller, Mark C; Kharlamov, Alexander; Merrell, Gregory A; Palmer, Bradley A

    2018-05-01

    The aim of the study was to compare biomechanical strength, repair times, and repair values for zone II core flexor tendon repairs. A total of 75 fresh-frozen human cadaveric flexor tendons were harvested from the index through small finger and randomized into one of 5 repair groups: 4-stranded cross-stitch cruciate (4-0 polyester and 4-0 braided suture), 4-stranded double Pennington (2-0 knotless barbed suture), 4-stranded Pennington (4-0 double-stranded braided suture), and 6-stranded modified Lim-Tsai (4-0 looped braided suture). Repairs were measured in situ and their repair times were measured. Tendons were linearly loaded to failure and multiple biomechanical values were measured. The repair value was calculated based on operating room costs, repair times, and suture costs. Analysis of variance (ANOVA) and Tukey post hoc statistical analysis were used to compare repair data. The braided cruciate was the strongest repair ( P > .05) but the slowest ( P > .05), and the 4-stranded Pennington using double-stranded suture was the fastest ( P > .05) to perform. The total repair value was the highest for braided cruciate ( P > .05) compared with all other repairs. Barbed suture did not outperform any repairs in any categories. The braided cruciate was the strongest of the tested flexor tendon repairs. The 2-mm gapping and maximum load to failure for this repair approached similar historical strength of other 6- and 8-stranded repairs. In this study, suture cost was negligible in the overall repair cost and should be not a determining factor in choosing a repair.

  17. A global picture of pharmacy technician and other pharmacy support workforce cadres

    NARCIS (Netherlands)

    Koehler, Tamara; Brown, A.

    a b s t r a c t Introduction: Understanding how pharmacy technicians and other pharmacy support workforce cadres assist pharmacists in the healthcare system will facilitate developing health systems with the ability to achieve universal health coverage as it is defined in different country contexts.

  18. A Canadian Approach to Training Technicians and Technologists In the Earth Sciences.

    Science.gov (United States)

    Watts, Stephen H.

    1983-01-01

    Describes two- and three-year undergraduate curricula for training earth science technicians at Sir Sanford Fleming College (Canada), emphasizing practical aspects and close student-faculty interaction. List of employment opportunities for geology graduates based on past placement data and geology curriculum outline are provided in tables. (JN)

  19. Factors that influence standard automated perimetry test results in glaucoma: test reliability, technician experience, time of day, and season.

    Science.gov (United States)

    Junoy Montolio, Francisco G; Wesselink, Christiaan; Gordijn, Marijke; Jansonius, Nomdo M

    2012-10-09

    To determine the influence of several factors on standard automated perimetry test results in glaucoma. Longitudinal Humphrey field analyzer 30-2 Swedish interactive threshold algorithm data from 160 eyes of 160 glaucoma patients were used. The influence of technician experience, time of day, and season on the mean deviation (MD) was determined by performing linear regression analysis of MD against time on a series of visual fields and subsequently performing a multiple linear regression analysis with the MD residuals as dependent variable and the factors mentioned above as independent variables. Analyses were performed with and without adjustment for the test reliability (fixation losses and false-positive and false-negative answers) and with and without stratification according to disease stage (baseline MD). Mean follow-up was 9.4 years, with on average 10.8 tests per patient. Technician experience, time of day, and season were associated with the MD. Approximately 0.2 dB lower MD values were found for inexperienced technicians (P Technician experience, time of day, season, and the percentage of false-positive answers have a significant influence on the MD of standard automated perimetry.

  20. Electrical field stimulation promotes anastomotic healing in poorly perfused rat colon.

    LENUS (Irish Health Repository)

    Kennelly, Rory

    2011-03-01

    Hypoperfusion of the bowel is a risk factor for anastomotic failure. Electrical field stimulation has been shown to improve repair in ischemic tissue, but its influence in hypoperfused colon has not been investigated. The hypothesis of this experimental animal study was that electrical field stimulation improves anastomotic healing in ischemic bowel.

  1. Reconstruction of fingers after electrical injury using lateral tarsal artery flap

    Directory of Open Access Journals (Sweden)

    Zhang MH

    2017-07-01

    Full Text Available Minghua Zhang, Mitao Huang, Pihong Zhang, Pengfei Liang, Licheng Ren, Jizhang Zeng, Jie Zhou, Xiong Liu, Tinghong Xie, Xiaoyuan Huang Department of Burns Reconstruction Surgery, Xiangya Hospital, Central South University, Changsha, Hunan, People’s Republic of China Objective: Electrical injuries to the fingers account for the majority of total severe burns that occur each year. While several types of flaps have been used in covering finger defects, all have limitations or disadvantages. The purpose of this study was to introduce our clinical experiences of using the lateral tarsal artery (LTA flap to successfully restore fingers after electrical injury.Patients and methods: From 2005 to 2012, 10 patients with 14 severe electrical burns to their fingers, including six thumbs and four index and four middle fingers, were treated with LTA flap. The wound size ranged from 2.0×3.0 cm to 3.5×5.0 cm. The flap with free tendon graft was used to repair the tendon defect in four cases, free nerve graft was used to repair the feeling defect in two cases, and the flap with nerve was used to repair the feeling defect in two cases. All the patients were followed up for 3 months to 2 years.Results: All skin flaps adhered successfully and there were no complications. All patients were satisfied with the esthetic appearance and functional outcome of the finger reconstruction.Conclusion: LTA flap is a reliable method to restore fingers after severe electrical injuries. Keywords: electrical injuries to fingers, lateral tarsal artery flap

  2. Development of a Pharmacy Technician-Driven Program to Improve Vaccination Rates at an Academic Medical Center.

    Science.gov (United States)

    Hill, John D; Anderegg, Sammuel V; Couldry, Rick J

    2017-10-01

    Background: Influenza and pneumococcal disease contribute substantially to the burden of preventable disease in the United States. Despite quality measures tied to immunization rates, health systems have struggled to achieve these targets in the inpatient setting. Pharmacy departments have had success through implementation of pharmacist standing order programs (SOP); however, these initiatives are labor-intensive and have not resulted in 100% immunization rates. Objective: The objective of this study was to evaluate a pilot utilizing pharmacy technician interventions, in combination with a nursing SOP, to improve vaccination rates of hospitalized patients for influenza and pneumococcal disease. Methods: A process was developed for pharmacy technicians to identify patients who were not previously screened or immunized during the weekend days on the Cardiovascular Progressive Care unit at the University of Kansas Health-System. Targeted pharmacy technician interventions consisted of phone call reminders and face-to-face discussions with nursing staff. The primary study outcome was the change in immunization compliance rates between the control and intervention groups. Results: Influenza vaccine rates showed a statistically significant increase from 72.2% (52 of 72) of patients during the control group to 92.9% (65 of 70, P = .001) of patients during the intervention group. A pneumococcal vaccination rate of 81.3% (61 of 75) was observed in the control group, compared with 84.3% (59 of 70) of patients in the intervention group ( P = .638). Conclusion: An improvement in inpatient influenza immunization rates can be achieved through targeted follow-up performed by pharmacy technicians, in combination with a nursing-driven SOP.

  3. The role of the pharmacy technician in the skill-mixed district nursing team.

    Science.gov (United States)

    McGraw, Caroline; Coleman, Bridget; Ashman, Lea; Hayes, Sarah

    2012-09-01

    Registered nurses in the district nursing service delegate a broad range of medication administration activities to healthcare assistants. Although healthcare assistants have provided extra capacity, not all activities are suitable for delegation to unregulated practitioners. At the same time, their competency assessment is often patient-specific and demands significant registered nursing input. The purpose of this 6-month pilot programme was to test the premise that the employment of a pharmacy technician in the district nursing service would enhance productivity levels and deliver cost savings. Activities delegated included the administration of oral tablets and subcutaneous insulin and low molecular weight heparin injections. The evaluation found that the introduction of the pharmacy technician was associated with neither enhanced productivity nor more than modest cost savings. However, role redesign is a long-term activity and their role could be built on with further competency analysis.

  4. General Electric's training program for BWR chemists

    International Nuclear Information System (INIS)

    Osborn, R.N.; Lim, W.

    1981-01-01

    This paper describes the development and implementation of the General Electric boiling water reactor chemistry training program from 1959 to the present. The original intention of this program was to provide practical hands on type training in radiochemistry to BWR chemistry supervisors with fossil station experience. This emphasis on radiochemistry has not changed through the years, but the training has expanded to include the high purity water chemistry of the BWR and has been modified to include new commission requirements, engineering developments and advanced instrumentation. Student and instructor qualifications are discussed and a description of the spin off courses for chemistry technicians and refresher training is presented

  5. Medication reconciliation by a pharmacy technician in a mental health assessment unit.

    Science.gov (United States)

    Brownlie, Kay; Schneider, Carl; Culliford, Roger; Fox, Chris; Boukouvalas, Alexis; Willan, Cathy; Maidment, Ian D

    2014-04-01

    Medication discrepancies are common when patients cross organisational boundaries. However, little is known about the frequency of discrepancies within mental health and the efficacy of interventions to reduce discrepancies. To evaluate the impact of a pharmacy-led reconciliation service on medication discrepancies on admissions to a secondary care mental health trust. In-patient mental health services. Prospective evaluation of pharmacy technician led medication reconciliation for admissions to a UK Mental Health NHS Trust. From March to June 2012 information on any unintentional discrepancies (dose, frequency and name of medication); patient demographics;and type and cause of the discrepancy was collected. The potential for harm was assessed based on two scenarios; the discrepancy was continued into primary care, and the discrepancy was corrected during admission. Logistic regression identified factors associated with discrepancies. Mean number of discrepancies per admission corrected by the pharmacy technician. Unintentional medication discrepancies occurred in 212 of 377 admissions (56.2 %). Discrepancies involving 569 medicines (mean 1.5 medicines per admission) were corrected.The most common discrepancy was omission(n = 464). Severity was assessed for 114 discrepancies. If the discrepancy was corrected within 16 days the potential harm was minor in 71 (62.3 %) cases and moderate in 43(37.7 %) cases whereas if the discrepancy was not corrected the potential harm was minor in 27 (23.7 %) cases and moderate in 87 (76.3 %) cases. Discrepancies were associated with both age and number of medications; the stronger association was age. Medication discrepancies are common within mental health services with potentially significant consequences for patients.Trained pharmacy technicians are able to reduce the frequency of discrepancies, improving safety.

  6. Brain aneurysm repair

    Science.gov (United States)

    ... aneurysm repair; Dissecting aneurysm repair; Endovascular aneurysm repair - brain; Subarachnoid hemorrhage - aneurysm ... Your scalp, skull, and the coverings of the brain are opened. A metal clip is placed at ...

  7. Rapid road repair vehicle

    Science.gov (United States)

    Mara, Leo M.

    1998-01-01

    Disclosed is a rapid road repair vehicle capable of moving over a surface to be repaired at near normal posted traffic speeds to scan for and find an the high rate of speed, imperfections in the pavement surface, prepare the surface imperfection for repair by air pressure and vacuum cleaning, applying a correct amount of the correct patching material to effect the repair, smooth the resulting repaired surface, and catalog the location and quality of the repairs for maintenance records of the road surface. The rapid road repair vehicle can repair surface imperfections at lower cost, improved quality, at a higher rate of speed than was was heretofor possible, with significantly reduced exposure to safety and health hazards associated with this kind of road repair activities in the past.

  8. Instrument for analysis of electric motors based on slip-poles component

    Science.gov (United States)

    Haynes, Howard D.; Ayers, Curtis W.; Casada, Donald A.

    1996-01-01

    A new instrument for monitoring the condition and speed of an operating electric motor from a remote location. The slip-poles component is derived from a motor current signal. The magnitude of the slip-poles component provides the basis for a motor condition monitor, while the frequency of the slip-poles component provides the basis for a motor speed monitor. The result is a simple-to-understand motor health monitor in an easy-to-use package. Straightforward indications of motor speed, motor running current, motor condition (e.g., rotor bar condition) and synthesized motor sound (audible indication of motor condition) are provided. With the device, a relatively untrained worker can diagnose electric motors in the field without requiring the presence of a trained engineer or technician.

  9. electricity infrastructure failure and the development of micro sized ...

    African Journals Online (AJOL)

    BARTH EKWUEME

    rated first by the respondents followed by water and roads. Though, corruption ... be increased. KEY WORDS: Electricity, Infrastructure and microenterprises. 1. .... well as pay taxes. There are ... cobblers, cars and radio repairers. Some of them.

  10. Multiple Learning Strategies Project. Small Engine Repair Service. Regular Vocational. [Vol. 1.

    Science.gov (United States)

    Pitts, Jim; And Others

    This instructional package is one of two designed for use by regular vocational students in the vocational area of small engine repair service. Contained in this document are forty-four learning modules organized into ten units: engine block; air cleaner; starters; fuel tanks; lines, filters, and pumps; carburetors; electrical; magneto systems;…

  11. Optimizing pressurized contact area in rotator cuff repair: the diamondback repair.

    Science.gov (United States)

    Burkhart, Stephen S; Denard, Patrick J; Obopilwe, Elifho; Mazzocca, Augustus D

    2012-02-01

    The purpose of this study was to compare tendon-bone footprint contact area over time under physiologic loads for 4 different rotator cuff repair techniques: single row (SR), triangle double row (DR), chain-link double row (CL), and diamondback double row (DBK). A supraspinatus tear was created in 28 human cadavers. Tears were fixed with 1 of 4 constructs: SR, DR, CL, or DBK. Immediate post-repair measurements of pressurized contact area were taken in neutral rotation and 0° of abduction. After a static tensile load, pressurized contact area was observed over a 160-minute period after repair. Cyclic loading was then performed. The DBK repair had the highest pressurized contact area initially, as well as the highest pressurized contact area and lowest percentage decrease in pressurized contact area after 160 minutes of testing. The DBK repair had significantly larger initial pressurized contact than CL (P = .003) and SR (P = .004) but not DR (P = .06). The DBK technique was the only technique that produced a pressurized contact area that exceeded the native footprint both at initial repair (P = .01) and after 160 minutes of testing (P = .01). DBK had a significantly larger mean pressurized contact area than all the repairs after 160 minutes of testing (P = .01). DBK had a significantly larger post-cyclic loading pressurized contact area than CL (P = .01) and SR (P = .004) but not DR (P = .07). This study showed that a diamondback repair (a modification of the transosseous repair) can significantly increase the rotator cuff pressurized contact area in comparison with other standard rotator cuff repair constructs when there is sufficient tendon mobility to perform a double-row repair without excessive tension on the repair site. The persistent pressurized contact area of a DBK repair may be desirable to enhance healing potential when there is sufficient tendon mobility to perform a double-row repair, particularly for large or massive rotator cuff tears where it is

  12. Radiological Control Technician: Phase 1, Site academic training study guides

    International Nuclear Information System (INIS)

    1992-10-01

    This volume is a study guide for training Radiological Control Technicians. Provided herein are support materials for learning radiological documentation, communication systems, counting errors and statistics, dosimetry, contamination control, airborne sampling program methods, respiratory protection, radiological source control, environmental monitoring, access control and work area setup, radiological work coverage, shipment and receipt for radioactive material, radiological incidents and emergencies, personnel decontamination, first aid, radiation survey instrumentation, contamination monitoring, air sampling, and counting room equipment

  13. Outbreak of hepatitis C virus infection associated with narcotics diversion by an hepatitis C virus-infected surgical technician.

    Science.gov (United States)

    Warner, Amy E; Schaefer, Melissa K; Patel, Priti R; Drobeniuc, Jan; Xia, Guoliang; Lin, Yulin; Khudyakov, Yury; Vonderwahl, Candace W; Miller, Lisa; Thompson, Nicola D

    2015-01-01

    Drug diversion by health care personnel poses a risk for serious patient harm. Public health identified 2 patients diagnosed with acute hepatitis C virus (HCV) infection who shared a common link with a hospital. Further investigation implicated a drug-diverting, HCV-infected surgical technician who was subsequently employed at an ambulatory surgical center. Patients at the 2 facilities were offered testing for HCV infection if they were potentially exposed. Serum from the surgical technician and patients testing positive for HCV but without evidence of infection before their surgical procedure was further tested to determine HCV genotype and quasi-species sequences. Parenteral medication handling practices at the 2 facilities were evaluated. The 2 facilities notified 5970 patients of their possible exposure to HCV, 88% of whom were tested and had results reported to the state public health departments. Eighteen patients had HCV highly related to the surgical technician's virus. The surgical technician gained unauthorized access to fentanyl owing to limitations in procedures for securing controlled substances. Public health surveillance identified an outbreak of HCV infection due to an infected health care provider engaged in diversion of injectable narcotics. The investigation highlights the value of public health surveillance in identifying HCV outbreaks and uncovering a method of drug diversion and its impacts on patients. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. All rights reserved.

  14. Reduction in respiratory motion artefacts on gadoxetate-enhanced MRI after training technicians to apply a simple and more patient-adapted breathing command

    International Nuclear Information System (INIS)

    Gutzeit, Andreas; Matoori, Simon; Weymarn, Constantin von; Reischauer, Carolin; Goyen, Matthias; Hergan, Klaus; Meissnitzer, Matthias; Forstner, Rosemarie; Froehlich, Johannes M.; Kolokythas, Orpheus; Soyka, Jan D.; Doert, Aleksis; Koh, Dow-Mu

    2016-01-01

    To investigate whether a trained group of technicians using a modified breathing command during gadoxetate-enhanced liver MRI reduces respiratory motion artefacts compared to non-trained technicians using a traditional breathing command. The gadoxetate-enhanced liver MR images of 30 patients acquired using the traditional breathing command and the subsequent 30 patients after training the technicians to use a modified breathing command were analyzed. A subgroup of patients (n = 8) underwent scans both by trained and untrained technicians. Images obtained using the traditional and modified breathing command were compared for the presence of breathing artefacts [respiratory artefact-based image quality scores from 1 (best) to 5 (non-diagnostic)]. There was a highly significant improvement in the arterial phase image quality scores in patients using the modified breathing command compared to the traditional one (P < 0.001). The percentage of patients with severe and extensive breathing artefacts in the arterial phase decreased from 33.3 % to 6.7 % after introducing the modified breathing command (P = 0.021). In the subgroup that underwent MRI using both breathing commands, arterial phase image quality improved significantly (P = 0.008) using the modified breathing command. Training technicians to use a modified breathing command significantly improved arterial phase image quality of gadoxetate-enhanced liver MRI. (orig.)

  15. Physician and Nurse Acceptance of Technicians to Screen for Geriatric Syndromes in the Emergency Department

    Directory of Open Access Journals (Sweden)

    Brian F Gage

    2011-05-01

    Full Text Available Introduction: The objective of this study was to evaluate emergency medicine physician and nurse acceptance of nonnurse, nonphysician screening for geriatric syndromes. Methods: This was a single-center emergency department (ED survey of physicians and nurses after an 8-month project. Geriatric technicians were paid medical student research assistants evaluating consenting ED patients older than 65 years for cognitive dysfunction, fall risk, or functional decline. The primary objective of this anonymous survey was to evaluate ED nurse and physician perceptions about the geriatric screener feasibility and barriers to implementation. In addition, as a secondary objective, respondents reported ongoing geriatric screening efforts independent of the research screeners. Results: The survey was completed by 72% of physicians and 33% of nurses. Most nurses and physicians identified geriatric technicians as beneficial to patients without impeding ED throughput. Fewer than 25% of physicians routinely screen for any geriatric syndromes. Nurses evaluated for fall risk significantly more often than physicians, but no other significant differences were noted in ongoing screening efforts. Conclusion: Dedicated geriatric technicians are perceived by nurses and physicians as beneficial to patients with the potential to improve patient safety and clinical outcomes. Most nurses and physicians are not currently screening for any geriatric syndromes. [West J Emerg Med. 2011;12(4:489–495.

  16. Electro-deposition as a repair method for embedded metal grids

    Energy Technology Data Exchange (ETDEWEB)

    Oostra, A. Jolt [Zernike Institute for Advanced Materials, University of Groningen, Nijenborgh 4, 9747 AG, Groningen (Netherlands); Reddy, Anil; Smits, Edsger C.P.; Abbel, Robert; Groen, Wilhelm A. [Holst Centre/TNO, High Tech Campus 31, 5605 KN Eindhoven (Netherlands); Blom, Paul W.M. [Max Planck Institute für Polymerforschung, Ackermannweg 10, 55128 Mainz (Germany); Michels, Jasper J., E-mail: michels@mpip-mainz.mpg.de [Holst Centre/TNO, High Tech Campus 31, 5605 KN Eindhoven (Netherlands); Max Planck Institute für Polymerforschung, Ackermannweg 10, 55128 Mainz (Germany)

    2016-03-31

    A method is presented to self-repair cracks in embedded silver grid structures used in large area organic electronics. The repair procedure is based on electro-deposition, incited by the application of a moderate DC voltage across the crack. During this process the organic anode that is in direct electrical contact with the silver grid, functions as an appropriate medium for ion migration. Restoration of conductivity is achieved by the formation of dendritic metal structures that connect the cathodic to the anodic side of the crack. The metal dendrites decrease the gap resistance by one order of magnitude. Subsequently, another three orders of magnitude are gained upon sintering the dendrites using a high voltage pulse, yielding restored conductance levels nearly within one order of magnitude difference from native track conductance. - Highlights: • An innovative method to repair cracks in embedded silver electrodes is presented. • The method targets application in flexible hybrid- and organic electronics. • The mechanism relies on dendritic growth of metallic structures. • Sintering yields restored conductivity levels approaching the original value.

  17. Qualification of electric motors class 1E for supply of motors and its repair; Calificacion de motores electricos clase 1E para el suministro de motores alternativos a los orginales y su reparacion

    Energy Technology Data Exchange (ETDEWEB)

    Perez, E.; Gonzalez, J. J.; Fernandez, A.; Garcia, D.

    2005-07-01

    Different original suppliers of nuclear grade equipment have either disappeared or discontinued the manufacture of this kind equipment. Under this situation nuclear plants are experiencing difficulties when dealing with the substitution or maintenance of these equipment. Tecnatom and Cantarey have developed a new line of Class 1E qualified electric low voltage motors which can be used as an alternative to originally installed safety-related motors or for its repair and maintenance. (Author)

  18. Methods for training radiochemical technicians at ORNL

    International Nuclear Information System (INIS)

    Parrott, J.R.; Nicol, R.G.

    The training of personnel to carry out radiochemical operations at ORNL is a formidable and recurrent task since programs are constantly shifting. It is essential that provisions be made for the routine retraining of these personnel if they are to make effective contributions on a continuing basis. Training methods are described that have emerged as a result of thirty years experience in a variety of radiochemical pilot-plant programs. Emphasis is placed on training programs for technicians for the 233 U Processing Facility since essentially all aspects of radiochemical operations are encountered in this facility. These programs have included operations performed in glove boxes, hot-cell manipulator work handling high-neutron-emitting isotopes, and the entire spectrum of remote solvent extraction operations. (U.S.)

  19. Impact of a pharmacy technician-centered medication reconciliation program on medication discrepancies and implementation of recommendations.

    Science.gov (United States)

    Kraus, Sarah K; Sen, Sanchita; Murphy, Michelle; Pontiggia, Laura

    2017-01-01

    To evaluate the impact of a pharmacy-technician centered medication reconciliation (PTMR) program by identifying and quantifying medication discrepancies and outcomes of pharmacist medication reconciliation recommendations. A retrospective chart review was performed on two-hundred patients admitted to the internal medicine teaching services at Cooper University Hospital in Camden, NJ. Patients were selected using a stratified systematic sample approach and were included if they received a pharmacy technician medication history and a pharmacist medication reconciliation at any point during their hospital admission. Pharmacist identified medication discrepancies were analyzed using descriptive statistics, bivariate analyses. Potential risk factors were identified using multivariate analyses, such as logistic regression and CART. The priority level of significance was set at 0.05. Three-hundred and sixty-five medication discrepancies were identified out of the 200 included patients. The four most common discrepancies were omission (64.7%), non-formulary omission (16.2%), dose discrepancy (10.1%), and frequency discrepancy (4.1%). Twenty-two percent of pharmacist recommendations were implemented by the prescriber within 72 hours. A PTMR program with dedicated pharmacy technicians and pharmacists identifies many medication discrepancies at admission and provides opportunities for pharmacist reconciliation recommendations.

  20. Impact of a pharmacy technician-centered medication reconciliation program on medication discrepancies and implementation of recommendations

    Directory of Open Access Journals (Sweden)

    Kraus SK

    2017-06-01

    Full Text Available Objectives: To evaluate the impact of a pharmacy-technician centered medication reconciliation (PTMR program by identifying and quantifying medication discrepancies and outcomes of pharmacist medication reconciliation recommendations. Methods: A retrospective chart review was performed on two-hundred patients admitted to the internal medicine teaching services at Cooper University Hospital in Camden, NJ. Patients were selected using a stratified systematic sample approach and were included if they received a pharmacy technician medication history and a pharmacist medication reconciliation at any point during their hospital admission. Pharmacist identified medication discrepancies were analyzed using descriptive statistics, bivariate analyses. Potential risk factors were identified using multivariate analyses, such as logistic regression and CART. The priority level of significance was set at 0.05. Results: Three-hundred and sixty-five medication discrepancies were identified out of the 200 included patients. The four most common discrepancies were omission (64.7%, non-formulary omission (16.2%, dose discrepancy (10.1%, and frequency discrepancy (4.1%. Twenty-two percent of pharmacist recommendations were implemented by the prescriber within 72 hours. Conclusion: A PTMR program with dedicated pharmacy technicians and pharmacists identifies many medication discrepancies at admission and provides opportunities for pharmacist reconciliation recommendations.

  1. A Mobile Robotic System for the Inspection and Repair of SG Tubes in NPPs

    Directory of Open Access Journals (Sweden)

    Yong-Chil Seo

    2016-04-01

    Full Text Available The reliability and performance of a steam generator (SG is one of the serious concerns in the operation of pressurized water nuclear power plants. Because of high levels of radiation, robotic systems have been used to inspect and repair SG tubes. In this paper, we present a mobile robotic system that positions the inspection and repair tools while hanging down from the tube sheets where the tubes are fixed. All of the driving mechanisms of the mobile robot are actuated by electric motors to start its works, providing that the electric power is prepared without the additional need for an on-site air services. A special tube-holding mechanism with a high holding force has been developed to prevent falling from the tube sheets, even in the case of an electric power failure. We have also developed a quick installation guide device that guides the mobile robot to desired initial positions in the tube sheet exactly and quickly, which helps to reduce the radiation exposure of human workers during the installation work. This paper also provides on-site experimental results and lessons learned.

  2. Fundamentals of electroheat electrical technologies for process heating

    CERN Document Server

    Lupi, Sergio

    2017-01-01

    This book provides a comprehensive overview of the main electrical technologies for process heating, which tend to be treated separately in specialized books. Individual chapters focus on heat transfer, electromagnetic fields in electro-technologies, arc furnaces, resistance furnaces, direct resistance heating, induction heating, and high-frequency and microwave heating. The authors highlight those topics of greatest relevance to a wide-ranging teaching program, and at the same time offer a detailed review of the main applications of the various technologies. The content represents a synthesis of the extensive knowledge and experience that the authors have accumulated while researching and teaching at the University of Padua’s Engineering Faculty. This text on industrial electroheating technologies is a valuable resource not only for students of industrial, electrical, chemical, and material science engineering, but also for engineers, technicians and others involved in the application of electroheating and...

  3. Adhesive liquid core optical fibers for crack detection and repairs in polymer and concrete matrices

    Science.gov (United States)

    Dry, Carolyn M.

    1995-04-01

    This work is an investigation into the feasibility of using liquid core optical fibers for the detection and self repair of cracking in cement or polymer materials generated by dynamic or static loading. These experiments rely on our current research sponsored by the National Science Foundation. It combines that work on the concept of internal adhesive delivery from hollow fibers for repair with nondestructive fiber optic analysis of the crack localization and volume within the same system. The need to monitor the internal state of civil structures and materials is great. Existing instrumentation techniques that mainly rely on magnetism, electricity, or stress gauges are limited if used for remote measurements in concrete or composites. They are sensitive to electrical magnetic noises and they degrade in the environment over time. Optical fibers are attractive because they are immune to electromagnetic interference and are sensitive over long distances. The combination of the ability to remotely measure crack occurrence in real time and determine the location and volume of crack damage in the matrix is unique in the field of optic sensors (or any sensors in general). The combination of this with crack repair, rebonding of any detached or broken fibers, and replenishment of liquid core chemicals, when necessary, make this a potentially powerful sensing and repair tool. Work on this research topic of the combination sponsored by the University of Illinois, looks very promising as a rapid innovative advance.

  4. Interaction Design of Augmented Education Environments - Augmented and Mixed Reality for performance and training support of Aviation / Automotive Technicians.

    OpenAIRE

    Behringer, R; Christian, J; Krieger, H; Moore, D; Holzinger, A

    2011-01-01

    "Augmented reality (AR),Mixed Reality (MR) and their mix and combination with other disruptive technologies offer an enormous potential for supporting instructors and trainees in modern education and working environments such as of aircraft maintenance technicians or automotive service technicians. In this paper we investigate and show some examples on how the performance and training of such instructors and trainees can be actively supported. Furthermore we will discuss the new challenges fo...

  5. Effect of individually tailored biopsychosocial workplace interventions on chronic musculoskeletal pain and stress among laboratory technicians

    DEFF Research Database (Denmark)

    Jay, Kenneth; Brandt, Mikkel; Hansen, Klaus

    2015-01-01

    BACKGROUND: Chronic musculoskeletal pain is prevalent among laboratory technicians and work-related stress may aggravate the problem. OBJECTIVES: This study investigated the effect of a multifaceted worksite intervention on pain and stress among laboratory technicians with chronic musculoskeletal......: neck, shoulder, lower and upper back, elbow, and hand at 10 week follow-up. The secondary outcome measure was stress assessed by Cohen´s perceived stress questionnaire. In addition, an explorative dose-response analysis was performed on the adherence to PCMT with pain and stress, respectively......, as outcome measures. RESULTS: A significant (P stress was observed (treatment by time P = 0.16). Exploratory analyses for each body...

  6. A global picture of pharmacy technician and other pharmacy support workforce cadres.

    Science.gov (United States)

    Koehler, Tamara; Brown, Andrew

    Understanding how pharmacy technicians and other pharmacy support workforce cadres assist pharmacists in the healthcare system will facilitate developing health systems with the ability to achieve universal health coverage as it is defined in different country contexts. The aim of this paper is to provide an overview of the present global variety in the technician and other pharmacy support workforce cadres considering; their scope, roles, supervision, education and legal framework. A structured online survey instrument was administered globally using the Survey Monkey platform, designed to address the following topic areas: roles, responsibilities, supervision, education and legislation. The survey was circulated to International Pharmaceutical Federation (FIP) member organisations and a variety of global list serves where pharmaceutical services are discussed. 193 entries from 67 countries and territories were included in the final analysis revealing a vast global variety with respect to the pharmacy support workforce. From no pharmacy technicians or other pharmacy support workforce cadres in Japan, through a variety of cadre interactions with pharmacists, to the autonomous practice of pharmacy support workforce cadres in Malawi. From strictly supervised practice with a focus on supply, through autonomous practice for a variety of responsibilities, to independent practice. From complete supervision for all tasks, through geographical varied supervision, to independent practice. From on the job training, through certificate level vocational courses, to 3-4 year diploma programs. From well-regulated and registered, through part regulation with weak implementation, to completely non-regulated contexts. This paper documents wide differences in supervision requirements, education systems and supportive legislation for pharmacy support workforce cadres globally. A more detailed understanding of specific country practice settings is required if the use of pharmacy

  7. Some areas of reliability technique which have been neglected to some extent - maintainability - human reliability - mechanical reliability - repairable systems

    International Nuclear Information System (INIS)

    Akersten, P.A.

    1985-01-01

    The present thesis consists of four papers, three of which are of a expositary nature and one more theoretical. The first two papers have a natural coupling to the man-machine interface. The first paper is devoted to the concept of maintainability and the role of man as maintenance technician. The second paper discusses aspects of human reliability, mainly studying man as operator. However, maintenance tasks can be studied in the same manner. The third paper concerns reliability prediction for mechanical components. This is an area of vital importance for the reliability practitioner, who needs realistic and easy-to-use mathematical models for different failure modes. The fourth paper discusses mathematical models for repairable systems, especially the problem of testing whether a constant event intensity model is adequate or not. (author)

  8. [The speech therapist in geriatrics: caregiver, technician-researcher, or both?].

    Science.gov (United States)

    Orellana, Blandine

    2015-01-01

    Geriatric care mostly consists not in curingthe patient, but supportingthem to the end of their life, giving meaning to care procedures and actions through speech, touch or look and maintaining a connection.The helping relationship is omnipresent and the role of the speech therapist is therefore essential in helping to maintain or re-establish elderly patients' abilityto communicate. However, todaythis role is struggling to define itself between that of the technician-researcher and that of caregiver.

  9. DNA repair

    International Nuclear Information System (INIS)

    Van Zeeland, A.A.

    1984-01-01

    In this chapter a series of DNA repair pathways are discussed which are available to the cell to cope with the problem of DNA damaged by chemical or physical agents. In the case of microorganisms our knowledge about the precise mechanism of each DNA repair pathway and the regulation of it has been improved considerably when mutants deficient in these repair mechanisms became available. In the case of mammalian cells in culture, until recently there were very little repair deficient mutants available, because in almost all mammalian cells in culture at least the diploid number of chromosomes is present. Therefore the frequency of repair deficient mutants in such populations is very low. Nevertheless because replica plating techniques are improving some mutants from Chinese hamsters ovary cells and L5178Y mouse lymphoma cells are now available. In the case of human cells, cultures obtained from patients with certain genetic diseases are available. A number of cells appear to be sensitive to some chemical or physical mutagens. These include cells from patients suffering from xeroderma pigmentosum, Ataxia telangiectasia, Fanconi's anemia, Cockayne's syndrome. However, only in the case of xeroderma pigmentosum cells, has the sensitivity to ultraviolet light been clearly correlated with a deficiency in excision repair of pyrimidine dimers. Furthermore the work with strains obtained from biopsies from man is difficult because these cells generally have low cloning efficiencies and also have a limited lifespan in vitro. It is therefore very important that more repair deficient mutants will become available from established cell lines from human or animal origin

  10. 14 CFR Appendix A to Part 43 - Major Alterations, Major Repairs, and Preventive Maintenance

    Science.gov (United States)

    2010-01-01

    ... absorbers, bracing, cowling, fairings, and balance weights. (ix) Hydraulic and electrical actuating system of components. (x) Rotor blades. (xi) Changes to the empty weight or empty balance which result in an... operations: (1) Removal, installation, and repair of landing gear tires. (2) Replacing elastic shock absorber...

  11. Strategies used by nursing technicians to face the occupational suffering in an emergency unit

    Directory of Open Access Journals (Sweden)

    Alessandra Bassalobre Garcia

    2016-05-01

    Full Text Available Objective: to understand the strategies used by nursing technicians in order to face the occupational suffering in an emergency room. Methods: qualitative study carried out in an emergency room of a high complexity hospital located in the north of Paraná state. Data were collected through semi-structured interviews with 12 nursing technicians. The analysis relied on content analysis procedures. Results: respondents revealed as individual strategies to face suffering: try not to get involved with the patient; separation between professional and personal life; and spirituality/religion as support for coping. The collective strategies described by respondents included: action planning for unexpected events in this unit; creating a supportive environment; and attempt to obtain recognition of headship. Conclusion: individual and collective strategies were used consciously by workers and should be encouraged by managers to face the occupational suffering.

  12. Electric motor predictive and preventive maintenance guide

    International Nuclear Information System (INIS)

    Oliver, J.A.

    1992-07-01

    Electric motor performance is vital to the reliable and efficient operation of power plants. The failure of one or more critical motors could cause lost capacity and excessive repair and maintenance cost. However, existing maintenance recommendations proposed by vendors for electric motors have sometimes encouraged many overly conservative maintenance practices. These practices have lead to excessive maintenance activities and costs which have provided no extra margin of operability. EPRI has sponsored RP2814-35 to develop a guide which provides power plants with information and guidance for establishing an effective maintenance program which will aid in preventing unexpected motor failures and assist in planning motor maintenance efforts. The guide includes a technical description which summarizes technical data relative to the four basic types of motors and their components in general use in power plants. The significant causes of motor failures are investigated and described in detail and methods to optimize service life and minimize maintenance cost through appropriate preventive maintenance and conditioning program are presented. This guide provides a foundation for an effective electric motor maintenance program and simplifies the selection of predictive and preventive maintenance tasks. Its use will enable maintenance personnel in nuclear and fossil plants to plan motor repairs during scheduled outages and avoid costly unexpected failures

  13. Training courses for radiological technicians: radiation protection of the patient and control of image quality

    International Nuclear Information System (INIS)

    Mateus Yoshimura, Elisabeth; Costa, Paulo Roberto; Furquim, Tania Aparecida; Freitas, Marcelo Baptista de; Valente, Marcelo; Cerri, Giovanni Guido

    2008-01-01

    Full text: As in other countries, life expectancy is increasing in Brazil, and the number of radiological examinations tends to increase. Old equipment and high technology ones cohabit, radiology technicians are not well prepared to conduct practices, images and doses to patients are not optimized. Digital techniques that began to be introduced in the last years are also an important issue, because, as it is possible to modify the image digitally, there is less concern about the choice of equipment parameters that produce the best-image/lowest-dose compromise. Pediatric radiology, CT and fluoroscopy require attention too, as they are of dosimetric interest or because the patient ages imply higher risks or because the techniques deliver higher doses than the conventional ones. In our opinion, the most important role that we can play is educating and forming people to work in this area: training programs and refreshing courses are a way of facing the problem. This way, we are organizing, in a technical cooperation with IAEA, two training courses in quality assurance and radiation protection in radiology, one designed to physicists (60 h), and the radiological technicians (40 h). An important cooperation with a paediatric and a general hospital made it possible to offer courses with 50% practical lessons, performed both in the University and in hospital equipment. Both courses cover a basic Radiation Physics program, radiation protection, image formation and quality control in conventional and digital equipment, and patient dosimetry. Equipment donated by IAEA facilitate the practical QA and dosimetry lessons. The rationale of our project is making it sustainable through the formation of physicists that will go on in the education process of technicians in technical schools. We present the results of the first two courses (physicists and technicians), considering the selection process, the development of the activities, and the assessment both of the students enrolled

  14. Repair kinetics in tissues

    International Nuclear Information System (INIS)

    Thames, H.D.

    1989-01-01

    Monoexponential repair kinetics is based on the assumption of a single, dose-independent rate of repair of sublethal injury in the target cells for tissue injury after exposure to ionizing radiation. Descriptions of the available data based on this assumption have proved fairly successful for both acutely responding (skin, lip mucosa, gut) and late-responding (lung, spinal cord) normal tissues. There are indications of biphasic exponential repair in both categories, however. Unfortunately, the data usually lack sufficient resolution to permit unambiguous determination of the repair rates. There are also indications that repair kinetics may depend on the size of the dose. The data are conflicting on this account, however, with suggestions of both faster and slower repair after larger doses. Indeed, experiments that have been explicitly designed to test this hypothesis show either no effect (gut, spinal cord), faster repair after higher doses (lung, kidney), or slower repair after higher doses (skin). Monoexponential repair appears to be a fairly accurate description that provides an approximation to a more complicated picture, the elucidation of whose details will, however, require very careful and extensive experimental study. (author). 30 refs.; 1 fig

  15. Power Product Equipment Technician: Outboard-Engine Boat Systems. Teacher Edition [and] Student Edition.

    Science.gov (United States)

    Hilley, Robert

    This curriculum guide contains teacher and student materials for a course on outboard-engine boat systems for power product equipment technician occupations. The course contains the following three units of instruction: (1) Orientation to Outboard-Engine Boat Systems and Rigging; (2) Trailers and Safe Towing and Boat Operation; and (3) Seasonal…

  16. Repair welding of cracked steam turbine blades using austenitic and martensitic stainless-steel consumables

    International Nuclear Information System (INIS)

    Bhaduri, A.K.; Gill, T.P.S.; Albert, S.K.; Shanmugam, K.; Iyer, D.R.

    2001-01-01

    The procedure for repair welding of cracked steam turbine blades made of martensitic stainless steels has been developed using the gas tungsten arc welding process. Weld repair procedures were developed using both ER 316L austenitic and ER 410 martensitic stainless-steel filler wire. The overall development of the repair welding procedure included selection of welding consumables (for austenitic filler metal), optimisation of post-weld heat treatment parameters, selection of suitable method for local pre-heating and post-weld heat treatment (PWHT) of the blades, determination of mechanical properties of weldments in as-welded and PWHT conditions, and microsturctural examination. After various trials using different procedures, the procedure of local PWHT (and preheating when using martensitic stainless-steel filler wire) using electrical resistance heating on the top surface of the weldment and monitoring the temperature by placing a thermocouple at the bottom of the weld was found to give the most satisfactory results. These procedures have been developed and/or applied for repair welding of cracked blades in steam turbines

  17. A geometric process repair model for a repairable cold standby system with priority in use and repair

    International Nuclear Information System (INIS)

    Zhang Yuanlin; Wang Guanjun

    2009-01-01

    In this paper, a deteriorating cold standby repairable system consisting of two dissimilar components and one repairman is studied. For each component, assume that the successive working times form a decreasing geometric process while the consecutive repair times constitute an increasing geometric process, and component 1 has priority in use and repair. Under these assumptions, we consider a replacement policy N based on the number of repairs of component 1 under which the system is replaced when the number of repairs of component 1 reaches N. Our problem is to determine an optimal policy N* such that the average cost rate (i.e. the long-run average cost per unit time) of the system is minimized. The explicit equation of the average cost rate of the system is derived and the corresponding optimal replacement policy N* can be determined analytically or numerically. Finally, a numerical example with Weibull distribution is given to illustrate some theoretical results in this paper.

  18. Phenomenology of an inducible mutagenic DNA repair pathway in Escherichia coli: SOS repair hypothesis

    International Nuclear Information System (INIS)

    Radman, M.

    1974-01-01

    A hypothesis is proposed according to which E. coli possesses an inducible DNA repair system. This hypothetical repair, which we call SOS repair, is manifested only following damage to DNA, and requires de novo protein synthesis. SOS repair in E. coli requires some known genetic elements: recA + , lex + and probably zab + . Mutagenesis by ultraviolet light is observed only under conditions of functional SOS repair: we therefore suspect that this is a mutation-prone repair. A number of phenomena and experiments is reviewed which at this point can best be interpreted in terms of an inducible mutagenic DNA repair system. Two recently discovered phenomena support the proposed hypothesis: existence of a mutant (tif) which, after a shift to elevated temperature, mimicks the effect of uv irradiation in regard to repair of phage lambda and uv mutagenesis, apparent activation of SOS repair by introduction into the recipient cell of damaged plasmid or Hfr DNA. Several specific predictions based on SOS repair hypothesis are presented in order to stimulate further experimental tests. (U.S.)

  19. Electrical Stimulation of Schwann Cells Promotes Sustained Increases in Neurite Outgrowth

    OpenAIRE

    Koppes, Abigail N.; Nordberg, Andrea L.; Paolillo, Gina M.; Goodsell, Nicole M.; Darwish, Haley A.; Zhang, Linxia; Thompson, Deanna M.

    2013-01-01

    Endogenous electric fields are instructive during embryogenesis by acting to direct cell migration, and postnatally, they can promote axonal growth after injury (McCaig 1991, Al-Majed 2000). However, the mechanisms for these changes are not well understood. Application of an appropriate electrical stimulus may increase the rate and success of nerve repair by directly promoting axonal growth. Previously, DC electrical stimulation at 50 mV/mm (1 mA, 8 h duration) was shown to promote neurite ou...

  20. Mountain Plains Learning Experience Guide: Radio and T.V. Repair. Course: D.C. Circuits.

    Science.gov (United States)

    Hoggatt, P.; And Others

    One of four individualized courses included in a radio and television repair curriculum, this course deals with the basic electrical properties of current, voltage, resistance, magnetism, mutual induction, and capacitance. The course is comprised of ten units: (1) Current, (2) Voltage, (3) Resistance, (4) Measuring Voltage and Current in Series…

  1. X-ray repair cross complementing protein 1 in base excision repair

    DEFF Research Database (Denmark)

    Hanssen-Bauer, Audun; Solvang-Garten, Karin; Akbari, Mansour

    2012-01-01

    X-ray Repair Cross Complementing protein 1 (XRCC1) acts as a scaffolding protein in the converging base excision repair (BER) and single strand break repair (SSBR) pathways. XRCC1 also interacts with itself and rapidly accumulates at sites of DNA damage. XRCC1 can thus mediate the assembly of large...

  2. Traumatic Tricuspid Insufficiency Requiring Valve Repair in an Acute Setting.

    Science.gov (United States)

    Enomoto, Yoshinori; Sudo, Yoshio; Sueta, Tomonori

    2015-01-01

    Tricuspid insufficiency due to penetrating cardiac trauma is rare. Patients with tricuspid insufficiency due to trauma can tolerate this abnormality for months or even years. We report a case of a 66-year-old female with penetrating cardiac trauma on the right side of her heart that required tricuspid valve repair in an acute setting. She sustained cut and stab wounds on her bilateral forearms and in the neck and epigastric region. She had cardiac tamponade and developed pulseless electrical activity, which required emergency surgery. The right ventricle and superior vena cava were dissected approximately 5 cm and 2 cm, respectively. After these wounds had been repaired, the patient's inability to wean from cardiopulmonary bypass suggested rightsided heart failure; transesophageal echocardiography revealed tricuspid insufficiency. Right atriotomy was performed, and a detailed examination revealed that the tricuspid valve septal leaflet was split in two. There was also an atrial septal injury that created a connection with the left atrium; these injuries were not detected from the right ventricular wound. After repair, weaning from cardiopulmonary bypass with mild tricuspid insufficiency was achieved, and she recovered uneventfully. This case emphasized the importance of thoroughly investigating intracardiac injury and transesophageal echocardiography.

  3. Analysis for a two-dissimilar-component cold standby repairable system with repair priority

    International Nuclear Information System (INIS)

    Leung, Kit Nam Francis; Zhang Yuanlin; Lai, Kin Keung

    2011-01-01

    In this paper, a cold standby repairable system consisting of two dissimilar components and one repairman is studied. Assume that working time distributions and repair time distributions of the two components are both exponential, and Component 1 has repair priority when both components are broken down. After repair, Component 1 follows a geometric process repair while Component 2 obeys a perfect repair. Under these assumptions, using the perfect repair model, the geometric process repair model and the supplementary variable technique, we not only study some important reliability indices, but also consider a replacement policy T, under which the system is replaced when the working age of Component 1 reaches T. Our problem is to determine an optimal policy T* such that the long-run average loss per unit time (i.e. average loss rate) of the system is minimized. The explicit expression for the average loss rate of the system is derived, and the corresponding optimal replacement policy T* can be found numerically. Finally, a numerical example for replacement policy T is given to illustrate some theoretical results and the model's applicability. - Highlights: → A two-dissimilar-component cold standby system with repair priority is formulated. → The successive up/repair times of Component 1 form a decreasing/increasing geometric process. → Not only some reliability indices but also a replacement policy are studied.

  4. Lack of knowledge regarding the microscopic diagnosis of malaria by technicians of the laboratory network in Luanda, Angola.

    Science.gov (United States)

    Nazaré-Pembele, García; Rojas, Lázara; Núñez, Fidel Ángel

    2016-03-03

    Malaria is still one of the most important public health problems worldwide. The diagnosis of this disease is still mainly based on thick blood films.  To evaluate the knowledge about malaria diagnosis of the technicians of the public health network in Luanda, Angola, by means of a survey.  This survey was carried out in three phases. In the first one, open interviews were done to technicians related with the different procedures for malaria diagnosis. In the second one, a preliminary questionnaire was prepared and evaluated. In the third phase, a definitive questionnaire was applied to 120 technicians from Luanda between April and July, 2013. The proportions of correct and incorrect answers were compared for every question of the survey.  Significantly higher proportions of incorrect answers (p<0.05) were found in the questions related to clinical manifestations, 68/52 (p<0.05), species of Plasmodium according to geographical areas, 76/44 (p<0.05), the type of granulations according to species, 96/24 (p<0.01), the class of microscope magnifying glasses used to observe the thick smear, 105/15 (p<0.01), the thick smear report, 76/44 (p<0.01), the time and preparation of different stain solutions, 81/39 (p<0.01), and the number of parasites counted per 200 leukocytes, 96/24 (p<0.01).  Various failures for the microscopic diagnosis of malaria were observed amongst the evaluated technicians. These results will be useful as a baseline study before applying an educational intervention aimed to improve the quality of malaria diagnosis in Luanda's laboratory network.

  5. An Expert System Solution for the Quantitative Condition Assessment of Electrical Distribution Systems in the United States Air Force

    Science.gov (United States)

    1991-09-01

    Distribution system ... ......... 4 2. Architechture of an Expert system .. .............. 66 vi List of Tables Table Page 1. Prototype Component Model...expert system to properly process work requests Ln civil engineering (8:23). Electric Power Research Institute (EPRI). EPRI is a private organization ...used (51) Training Level. The level of training shop technicians receive, and the resulting proficiency, are important in all organizations . Experts 1

  6. Implementation of a laboratory for manufacture, repair and electric calibration of dosemeters based in ionization chambers utilized in radiotherapy; Implementacao de um laboratorio para manutencao, reparo e calibracao eletrica de dosimetros baseados em camaras de ionizacao, utilizados em radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Becker, P.H.B.; Peres, M.A.L.; Moreira, A.J.C.; Nette, H.P. [Instituto de Radioprotecao e Dosimetria. Av. Salvador Allende S/N. Barra de Tijuca CEP: 22780-160. Caixa Postal: 37750 Rio de Janeiro-RJ (Brazil)

    1998-12-31

    Manufacturers of ionization chamber dosimeters for radiotherapy maintain only sales representatives in Brazil with no servicing capability causing difficulties to customers/users to get broken equipment back into operation. Aiming to partially solve this problem, a laboratory for maintenance, repair and electrical calibration was started in 1995 with the support of a two year IAEA Technical Assistance Project (BRA/1/031). (Author)

  7. 40 CFR 798.5500 - Differential growth inhibition of repair proficient and repair deficient bacteria: “Bacterial DNA...

    Science.gov (United States)

    2010-07-01

    ... repair proficient and repair deficient bacteria: âBacterial DNA damage or repair tests.â 798.5500 Section... inhibition of repair proficient and repair deficient bacteria: “Bacterial DNA damage or repair tests.” (a... killing or growth inhibition of repair deficient bacteria in a set of repair proficient and deficient...

  8. Laboratory services series: an electrical outlet and corded equipment inspection program

    International Nuclear Information System (INIS)

    Davis, E.A.

    1976-04-01

    A research and development laboratory has thousands of electrical outlets providing power to laboratories, offices, shops, and service areas. These outlets provide power for a wide variety of portable equipment and tools that are equipped with cord and plug. Electric safety requires a periodic check of outlet grounding capability and continuing inspection and repair of corded equipment. Personnel, equipment, reports, procedures, and schedule requirements are reported

  9. Technician support for operation and maintenance of large fusion experiments: the tandem mirror experiment upgrade (TMX-U) approach

    International Nuclear Information System (INIS)

    Mattson, G.E.

    1983-01-01

    As experiments continue to grow in size and complexity, a few technicians will no longer be able to maintain and operate the complete experiment. Specialization is becoming the norm. Subsystems are becoming very large and complex, requiring a great deal of experience and training for technicians to become qualified maintenance/operation personnel. Formal in-house and off-site programs supplement on-the-job training to fulfill the qualification criteria. This paper presents the Tandem Mirror Experiment-Upgrade (TMX-U) approach to manpower staffing, some problems encountered, possible improvements, and safety considerations for the successful operation of a large experimental facility

  10. Multidisciplinary training program to create new breed of radiation monitor: the health and safety technician

    International Nuclear Information System (INIS)

    Vance, W.F.

    1979-01-01

    A multidiscipline training program established to create a new monitor, theHealth and Safety Technician, is described. The training program includes instruction in fire safety, explosives safety, industrial hygiene, industrial safety, health physics, and general safety practices

  11. DNA repair protocols

    DEFF Research Database (Denmark)

    Bjergbæk, Lotte

    In its 3rd edition, this Methods in Molecular Biology(TM) book covers the eukaryotic response to genomic insult including advanced protocols and standard techniques in the field of DNA repair. Offers expert guidance for DNA repair, recombination, and replication. Current knowledge of the mechanisms...... that regulate DNA repair has grown significantly over the past years with technology advances such as RNA interference, advanced proteomics and microscopy as well as high throughput screens. The third edition of DNA Repair Protocols covers various aspects of the eukaryotic response to genomic insult including...... recent advanced protocols as well as standard techniques used in the field of DNA repair. Both mammalian and non-mammalian model organisms are covered in the book, and many of the techniques can be applied with only minor modifications to other systems than the one described. Written in the highly...

  12. DNA repair in human cells

    International Nuclear Information System (INIS)

    Regan, J.D.; Carrier, W.L.; Kusano, I.; Furuno-Fukushi, I.; Dunn, W.C. Jr.; Francis, A.A.; Lee, W.H.

    1982-01-01

    Our primary objective is to elucidate the molecular events in human cells when cellular macromolecules such as DNA are damaged by radiation or chemical agents. We study and characterize (i) the sequence of DNA repair events, (ii) the various modalities of repair, (iii) the genetic inhibition of repair due to mutation, (iv) the physiological inhibition of repair due to mutation, (v) the physiological inhibition of repair due to biochemical inhibitors, and (vi) the genetic basis of repair. Our ultimate goals are to (i) isolate and analyze the repair component of the mutagenic and/or carcinogenic event in human cells, and (ii) elucidate the magnitude and significance of this repair component as it impinges on the practical problems of human irradiation or exposure to actual or potential chemical mutagens and carcinogens. The significance of these studies lies in (i) the ubiquitousness of repair (most organisms, including man, have several complex repair systems), (ii) the belief that mutagenic and carcinogenic events may arise only from residual (nonrepaired) lesions or that error-prone repair systems may be the major induction mechanisms of the mutagenic or carcinogenic event, and (iii) the clear association of repair defects and highly carcinogenic disease states in man [xeroderma pigmentosum (XP)

  13. Flexor tendon repair: a comparative study between a knotless barbed suture repair and a traditional four-strand monofilament suture repair.

    LENUS (Irish Health Repository)

    Joyce, C W

    2014-01-01

    We compared the tensile strength of a novel knotless barbed suture method with a traditional four-strand Adelaide technique for flexor tendon repairs. Forty fresh porcine flexor tendons were transected and randomly assigned to one of the repair groups before repair. Biomechanical testing demonstrated that the tensile strengths between both tendon groups were very similar. However, less force was required to create a 2 mm gap in the four-strand repair method compared with the knotless barbed technique. There was a significant reduction in the cross-sectional area in the barbed suture group after repair compared with the Adelaide group. This would create better gliding within the pulley system in vivo and could decrease gapping and tendon rupture.

  14. In vitro effects of direct current electric fields on adipose-derived stromal cells.

    Science.gov (United States)

    Hammerick, Kyle E; Longaker, Michael T; Prinz, Fritz B

    2010-06-18

    Endogenous electric fields play an important role in embryogenesis, regeneration, and wound repair and previous studies have shown that many populations of cells, leukocytes, fibroblasts, epithelial cells, and endothelial cells, exhibit directed migration in response to electric fields. As regenerative therapies continue to explore ways to control mesenchymal progenitor cells to recreate desirable tissues, it is increasingly necessary to characterize the vast nature of biological responses imposed by physical phenomena. Murine adipose-derived stromal cells (mASCs) migrated toward the cathode in direct current (DC) fields of physiologic strength and show a dose dependence of migration rate to stronger fields. Electric fields also caused mASCs to orient perpendicularly to the field vector and elicited a transient increase in cytosolic calcium. Additionally, their galvanotactic response appears to share classic chemotactic signaling pathways that are involved in the migration of other cell types. Galvanotaxis is one predominant result of electric fields on mASCs and it may be exploited to engineer adult stem cell concentrations and locations within implanted grafts or toward sites of wound repair. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  15. Student reactions to problem-based learning in photonics technician education

    Science.gov (United States)

    Massa, Nicholas M.; Donnelly, Judith; Hanes, Fenna

    2014-07-01

    Problem-based learning (PBL) is an instructional approach in which students learn problem-solving and teamwork skills by collaboratively solving complex real-world problems. Research shows that PBL improves student knowledge and retention, motivation, problem-solving skills, and the ability to skillfully apply knowledge in new and novel situations. One of the challenges faced by students accustomed to traditional didactic methods, however, is acclimating to the PBL process in which problem parameters are often ill-defined and ambiguous, often leading to frustration and disengagement with the learning process. To address this problem, the New England Board of Higher Education (NEBHE), funded by the National Science Foundation Advanced Technological Education (NSF-ATE) program, has created and field tested a comprehensive series of industry-based multimedia PBL "Challenges" designed to scaffold the development of students' problem solving and critical thinking skills. In this paper, we present the results of a pilot study conducted to examine student reactions to the PBL Challenges in photonics technician education. During the fall 2012 semester, students (n=12) in two associate degree level photonics courses engaged in PBL using the PBL Challenges. Qualitative and quantitative methods were used to assess student motivation, self-efficacy, critical thinking, metacognitive self-regulation, and peer learning using selected scales from the Motivated Strategies for Learning Questionnaire (MSLQ). Results showed positive gains in all variables. Follow-up focus group interviews yielded positive themes supporting the effectiveness of PBL in developing the knowledge, skills and attitudes of photonics technicians.

  16. PWR fuel inspection and repair technology development in the Republic of Korea

    International Nuclear Information System (INIS)

    Park, J.Y.

    1998-01-01

    As of September 1997, 10 PWRs and 2 PHWRs generate 10,320MW electricity in Korea. And another 8 PWRs and 2 PHWRs will be constructed by 2006. These will need about 400 MTU of PWR fuels and 400 MTU of PHWR fuels. To improve average burnup, thermal power, fuel usability and plant safety, better poolside fuel service technologies are strongly recommended as well as the fuel design and fabrication technology improvements. During the last twenty years of nuclear power plant operation in Korea, more than 4,000 fuel assemblies has been used. At the site, continuous coolant activity measurement, pool-side visual inspection and ultrasonic tests have been performed. Some of the fuels are damaged or failed for various reasons. Some of the defected fuels were examined in hot cell to investigate the cause of failure. Even though 30 PWR fuel assemblies were repaired by foreign engineers, fuel inspection and repair technologies are not established yet. Various kind of design for the fuel make the inspection, repair and reconstitution equipment more complex. As a result, recently, a plant to obtain overall technology for poolside fuel inspection, failed fuel repair and reconstitution through R and D activities are set forth. (author)

  17. Development of a Navy Job-Specific Vocational Interest Model

    Science.gov (United States)

    2006-12-01

    Enforcement Air Systems Installation/Repair Maritime Interests Applied Mathematics Media Arts Aviation Interests Medical and Dental Services...Technician (AS) 9. Aviation Electronics Technician (AT) 10. Aviation Maintenance Administrationman (AZ) 11. Culinary Specialist (CS) 12. Cryptologic...equipment. 90. Perform preventive and corrective maintenance on state-of-the- art electronic and electromechanical equipment and systems, requiring

  18. Exposure of aircraft maintenance technicians to organophosphates from hydraulic fluids and turbine oils: a pilot study.

    Science.gov (United States)

    Schindler, Birgit Karin; Koslitz, Stephan; Weiss, Tobias; Broding, Horst Christoph; Brüning, Thomas; Bünger, Jürgen

    2014-01-01

    Hydraulic fluids and turbine oils contain organophosphates like tricresyl phosphate isomers, triphenyl phosphate and tributyl phosphate from very small up to high percentages. The aim of this pilot study was to determine if aircraft maintenance technicians are exposed to relevant amounts of organophosphates. Dialkyl and diaryl phosphate metabolites of seven organophosphates were quantified in pre- and post-shift spot urine samples of technicians (N=5) by GC-MS/MS after solid phase extraction and derivatization. Pre- and post shift values of tributyl phosphate metabolites (dibutyl phosphate (DBP): median pre-shift: 12.5 μg/L, post-shift: 23.5 μg/L) and triphenyl phosphate metabolites (diphenyl phosphate (DPP): median pre-shift: 2.9 μg/L, post-shift: 3.5 μg/L) were statistically higher than in a control group from the general population (median DBP: <0.25 μg/L, median DPP: 0.5 μg/L). No tricresyl phosphate metabolites were detected. The aircraft maintenance technicians were occupationally exposed to tributyl and triphenyl phosphate but not to tricresyl phosphate, tri-(2-chloroethyl)- and tri-(2-chloropropyl)-phosphate. Further studies are necessary to collect information on sources, routes of uptake and varying exposures during different work tasks, evaluate possible health effects and to set up appropriate protective measures. Copyright © 2013 Elsevier GmbH. All rights reserved.

  19. RA Reactor operation and maintenance (I-IX), Part III, Task 3.08/04-02 Refurbishment of the electrical equipment; Pogon i odrzavanje reaktora RA (I-IX), III Deo, Zadatak 3.08/04-02 Remont elektro opreme

    Energy Technology Data Exchange (ETDEWEB)

    Zecevic, V; Nikolic, M; Poznanovic, B; Rajic, M [Institute of Nuclear Sciences Boris Kidric, Reaktor RA, Vinca, Beograd (Serbia and Montenegro)

    1963-12-15

    This volume contains detailed action plan for repair of electrical equipment of the RA reactor, the list of electrical equipment parts which were either repaired or exchanged for improvement of their performance. Detailed work describing the repair and maintenance work done of the listed equipment is part of this report. Equipment related to dosimetry and control systems are included as well.

  20. Accelerated electricity conservation in Juneau, Alaska: A study of household activities that reduced demand 25%

    International Nuclear Information System (INIS)

    Leighty, Wayne; Meier, Alan

    2011-01-01

    An avalanche destroyed the main hydroelectric transmission line to Juneau, Alaska in April, 2008. Diesel-generated electricity was substituted, causing electricity prices to increase 500% for 45 days. Electricity demand fell by 25% during the supply disruption. Most of the reduction occurred before the higher rates were implemented. Some conservation - about 8% of historic consumption - persisted after the transmission line was repaired and prices returned to normal. Consumers reduced energy use through a combination of new habits and technical improvements. A survey of residential consumers indicated that the average household undertook 10 conservation actions, with major changes in lighting, space heating, fuel switching, and water and appliance use. We propose a method for prioritizing conservation actions for promotion according to their impact in electricity savings (as a function of popularity, effectiveness, and persistence) and a dynamic framework for electricity use before, during, and after a supply disruption (i.e., both the magnitude and rates of change in electricity conservation). - Research highlights: → An electricity supply disruption caused prices to increase 500% for 45 days. → Electricity conservation of 25% occurred in a matter of days. → Electricity conservation of 8% persisted after the supply disruption was repaired. → Conservation occurred through behavior change and technology adoption. → The disruption induced consumers to try new behaviors that became new habits.

  1. Satisfaction, function and repair integrity after arthroscopic versus mini-open rotator cuff repair.

    Science.gov (United States)

    Barnes, L A Fink; Kim, H M; Caldwell, J-M; Buza, J; Ahmad, C S; Bigliani, L U; Levine, W N

    2017-02-01

    Advances in arthroscopic techniques for rotator cuff repair have made the mini-open approach less popular. However, the mini-open approach remains an important technique for repair for many surgeons. The aims of this study were to compare the integrity of the repair, the function of the shoulder and satisfaction post-operatively using these two techniques in patients aged > 50 years. We identified 22 patients treated with mini-open and 128 patients treated with arthroscopic rotator cuff repair of July 2007 and June 2011. The mean follow-up was two years (1 to 5). Outcome was assessed using the American Shoulder and Elbow Surgeons (ASES) and Simple Shoulder Test (SST) scores, and satisfaction. The integrity of the repair was assessed using ultrasonography. A power analysis ensured sufficient enrolment. There was no statistically significant difference between the age, function, satisfaction, or pain scores (p > 0.05) of the two groups. The integrity of the repair and the mean SST scores were significantly better in the mini-open group (91% of mini-open repairs were intact versus 60% of arthroscopic repairs, p = 0.023; mean SST score 10.9 (standard deviation (sd) 1.3) in the mini-open group; 8.9 (sd 3.5) in arthroscopic group; p = 0.003). The ASES scores were also higher in the mini-open group (mean ASES score 91.0 (sd 10.5) in mini-open group; mean 82.70 (sd 19.8) in the arthroscopic group; p = 0.048). The integrity of the repair and function of the shoulder were better after a mini-open repair than after arthroscopic repair of a rotator cuff tear in these patients. The functional difference did not translate into a difference in satisfaction. Mini-open rotator cuff repair remains a useful technique despite advances in arthroscopy. Cite this article: Bone Joint J 2017;99-B:245-9. ©2017 The British Editorial Society of Bone & Joint Surgery.

  2. Discount factor in planning decision of electric sector. A taxa de desconto nas decisoes de planejamento do setor eletrico

    Energy Technology Data Exchange (ETDEWEB)

    Becker, J L [Rio Grande do Sul Univ., Porto Alegre, RS (Brazil); Maurer, L T.A. [Booz, Allen and Hamilton Inc. (United States)

    1990-01-01

    Researchers and technicians have been giving a lot of attention to the issue of discount factor in planning in the electric sector. In this paper we review the most important points under consideration, attempting to broaden the discussion and stimulate the creativity of the technicians involved with the sector. There appears to be an emerging consensus that the discount factor to be used must consider the capital costs associated with the main financial sources utilized. The traditional factor of 10% per year must be re-evaluated and augmented, in order to best reflect long range economical and financial conditions. The paper emphasizes the importance of the discount factor to several decisions made within the sector, including energy conservation. Because of the relevance of the topic to Brazil future, we strongly suggest the utilization of sensitivity analysis techniques. (author).

  3. Peripherally Inserted Central Catheters in Pediatric Patients: To Repair or Not Repair

    International Nuclear Information System (INIS)

    Gnannt, Ralph; Patel, Premal; Temple, Michael; Al Brashdi, Yahya; Amaral, Joao; Parra, Dimitri; Rea, Vanessa; Stephens, Derek; Connolly, Bairbre

    2017-01-01

    IntroductionPreservation of venous access in children is a major concern in pediatric interventional radiology. If a peripherally inserted central catheter (PICC) breaks, there are two options: repair the line with a repair kit or exchange the line over a wire in the interventional suite. The purpose of this study is to assess the outcome of PICC repairs in children and to compare these with the outcomes of PICC exchange.Materials and MethodsThis is a single-center, retrospective study of central line-associated bloodstream infection (CLABSI) following management of externally broken PICCs (2010–2014). The occurrence of CLABSI within 30 days after repair (Group A) or exchange (Group B) of a line was analyzed, as well as PICCs exchanged following an initial and failed repair.ResultsA total of 235 PICC breaks were included in the study, of which 161 were repaired, and 116 of whom were successful (68%, Group A). No repair was performed in 74 PICCs—55/74 of these were exchanged over a wire (74%, Group B), and 19/74 lines were removed. The 30 days post-repair CLABSI rate (Group A) was 2.0 infections per 1000 catheter days, and the calculated risk was 4.3%. In comparison the 30 days post-exchange CLABSI rate (Group B) was 4.0 per 1000 catheter days and the calculated risk 10.9%. This difference was significant when adjusted for antibiotic use (OR 3.87; 95% CI 1.07–14.0, p = 0.039).ConclusionThe results of this study support repairing a broken PICC instead of removing or replacing the line.

  4. Peripherally Inserted Central Catheters in Pediatric Patients: To Repair or Not Repair

    Energy Technology Data Exchange (ETDEWEB)

    Gnannt, Ralph, E-mail: ralph.gnannt@usz.ch; Patel, Premal; Temple, Michael; Al Brashdi, Yahya; Amaral, Joao; Parra, Dimitri; Rea, Vanessa [University of Toronto, Image Guided Therapy, Diagnostic Imaging, The Hospital for Sick Children (Canada); Stephens, Derek [University of Toronto, Child Health Evaluative Sciences (Canada); Connolly, Bairbre [University of Toronto, Image Guided Therapy, Diagnostic Imaging, The Hospital for Sick Children (Canada)

    2017-06-15

    IntroductionPreservation of venous access in children is a major concern in pediatric interventional radiology. If a peripherally inserted central catheter (PICC) breaks, there are two options: repair the line with a repair kit or exchange the line over a wire in the interventional suite. The purpose of this study is to assess the outcome of PICC repairs in children and to compare these with the outcomes of PICC exchange.Materials and MethodsThis is a single-center, retrospective study of central line-associated bloodstream infection (CLABSI) following management of externally broken PICCs (2010–2014). The occurrence of CLABSI within 30 days after repair (Group A) or exchange (Group B) of a line was analyzed, as well as PICCs exchanged following an initial and failed repair.ResultsA total of 235 PICC breaks were included in the study, of which 161 were repaired, and 116 of whom were successful (68%, Group A). No repair was performed in 74 PICCs—55/74 of these were exchanged over a wire (74%, Group B), and 19/74 lines were removed. The 30 days post-repair CLABSI rate (Group A) was 2.0 infections per 1000 catheter days, and the calculated risk was 4.3%. In comparison the 30 days post-exchange CLABSI rate (Group B) was 4.0 per 1000 catheter days and the calculated risk 10.9%. This difference was significant when adjusted for antibiotic use (OR 3.87; 95% CI 1.07–14.0, p = 0.039).ConclusionThe results of this study support repairing a broken PICC instead of removing or replacing the line.

  5. Experience of Using Domestic High-Frequency Electric Welding Technology in Surgical Treatment of Patients with Abdominal Pathology

    Directory of Open Access Journals (Sweden)

    A.M. Babiy

    2014-04-01

    Full Text Available The article presents the experience of using electric welding technology of biological tissues with domestic high-frequency electrical generator EC 300 M1 in 176 patients at open and laparoscopic surgery for abdominal pathology. The analysis of findings showed that electric welding of living tissue provides reliable hemostasis, promotes tissue repair after their separation.

  6. Influence of repair length on residual stress in the repair weld of a clad plate

    International Nuclear Information System (INIS)

    Jiang Wenchun; Xu, X.P.; Gong, J.M.; Tu, S.T.

    2012-01-01

    Highlights: ► Residual stress in the repair weld of a stainless steel clad plate is investigated. ► The effect of repair length on residual stress has been studied. ► Large tensile residual stress is generated in the repair weld and heat affected zone. ► With the increase of repair length, transverse stress is decreased. ► Repair length has little effect on longitudinal stress. - Abstract: A 3-D sequential coupling finite element simulation is performed to investigate the temperature field and residual stress in the repair weld of a stainless steel clad plate. The effect of repair length on residual stress has been studied, aiming to provide a reference for repairing the cracked clad plate. The results show that large tensile residual stresses are generated in the repair weld and heat affected zone (HAZ), and then decrease gradually away from the weld and HAZ. The residual stresses through thickness in the clad layer are relative uniform, while they are non-uniform in the base metal. A discontinuous stress distribution is generated across the interface between weld metal and base metal. The repair length has a great effect on transverse stress. With the increase of repair length, the transverse stress is decreased. When the repair length is increased to 14 cm, the peak of transverse stress has been decreased below yield strength, and the transverse stress in the weld and HAZ has also been greatly decreased. But the repair length has little effect on longitudinal stress.

  7. PC Technician Street Smarts, Updated for the 2009 Exam A Real World Guide to CompTIA A+ Skills

    CERN Document Server

    Pyles, James

    2009-01-01

    An inside look into the life of a PC technician-from everyday tasks to the challenging roadblocks Gaining hands-on experience is considered the most difficult part of trying to break into the PC technician. Building on the standards set by CompTIA-and endorsed by the IT industry worldwide-this book takes you one step further than what you might simply learn in a classroom and shows you how to actually perform the various tasks you can expect to encounter on the job. The Street Smarts series is designed to help current or aspiring IT professionals put their certification to work for them. Full

  8. The role of the Senior Technician in Nursing as a response to the new model of research training

    Directory of Open Access Journals (Sweden)

    Lola Rosario Altamirano-Baquerizo

    2017-04-01

    Full Text Available This work is based on the recognition of the training needs presented by the students of the Higher Nursing Technician career of the Bolivarian Technological Institute of Technology, since it is presented as a regularity that research training is fundamentally associated with the search for bibliographic information And not as a tool for solving professional problems, together with the completion of the degree project. Therefore, it has as its objective the proposal of reflections of pedagogical nature that allow to understand the proposed model in the research training of the Higher Technician in Nursing in the Ecuadorian context. This result is a product of doctoral research.

  9. Medication reconciliation in pediatric cardiology performed by a pharmacy technician: a prospective cohort comparison study.

    Science.gov (United States)

    Chan, Carol; Woo, Renée; Seto, Winnie; Pong, Sandra; Gilhooly, Tessie; Russell, Jennifer

    2015-01-01

    Medication reconciliation reduces potential medication discrepancies and adverse drug events. The role of pharmacy technicians in obtaining best possible medication histories (BPMHs) and performing reconciliation at the admission and transfer interfaces of care for pediatric patients has not been described. To compare the completeness and accuracy of BPMHs and reconciliation conducted by a pharmacy technician (pilot study) and by nurses and/or pharmacists (baseline). The severity of identified unintentional discrepancies was rated to determine their clinical importance. This prospective cohort comparison study involved patients up to 18 years of age admitted to and/or transferred between the Cardiology ward and the Cardiac Critical Care Unit of a pediatric tertiary care teaching hospital. A pharmacy resident conducted two 3-week audits: the first to assess the completeness and accuracy of BPMHs and reconciliation performed by nurses and/or pharmacists and the second to assess the completeness and accuracy of BPMHs and reconciliation performed by a pharmacy technician. The total number of patients was 38 in the baseline phase and 46 in the pilot period. There were no statistically significant differences between the baseline and pilot audits in terms of completion of BPMH (82% [28/34] versus 78% [21/27], p = 0.75) or completion of reconciliation (70% [23/33] versus 75% [15/20], p = 0.76) within 24 h of admission. Completeness of transfer reconciliation was significantly higher during the pilot study than at baseline (91% [31/34] versus 61% [11/18], p = 0.022). No significant differences between the baseline and pilot audits were found in the proportions of patients with at least one BPMH discrepancy (38% [13/34] versus 22% [6/27], p = 0.27), at least one unintentional discrepancy upon admission (21% [7/33] versus 10% [2/20], p = 0.46), or at least one unintentional discrepancy at the transfer interface (6% [1/18] versus 3% [1/34], p = 0.58). None of the 16

  10. Power Product Equipment Technician: Outboard-Engine Systems and Service. Teacher Edition [and] Student Edition.

    Science.gov (United States)

    Hilley, Robert

    This curriculum guide contains teacher and student materials for a course on outboard-engine boat systems and service for power product equipment technician occupations. The course contains the following four units of instruction: (1) Outboard-Engine Design and Identification; (2) Operation and Service of Engine-Support Systems; (3) Operation and…

  11. Efficient Healing Takes Some Nerve: Electrical Stimulation Enhances Innervation in Cutaneous Human Wounds.

    Science.gov (United States)

    Emmerson, Elaine

    2017-03-01

    Cutaneous nerves extend throughout the dermis and epidermis and control both the functional and reparative capacity of the skin. Denervation of the skin impairs cutaneous healing, presenting evidence that nerves provide cues essential for timely wound repair. Sebastian et al. demonstrate that electrical stimulation promotes reinnervation and neural differentiation in human acute wounds, thus accelerating wound repair. Copyright © 2016 The Author. Published by Elsevier Inc. All rights reserved.

  12. Electrical safety in health care area

    International Nuclear Information System (INIS)

    Amer, G.M.

    2011-01-01

    An electrical safety in health care area is necessary to protect patients and staff from potential electrical hazards.Functional, accurate and safe clinical equipment is an essential requirement in the provision of health services. Well-maintained equipment will give clinicians greater confidence in the reliability of its performance and contribute to a high standard of client care. Clinical equipment, like all health services, requires annual or periodic servicing of medical equipment. In addition to planned servicing and preventative maintenance, there may be the unexpected failure of medical (and other) equipment, necessitating repair. In general, clinical equipment that has an electrical power source and has direct contact with the client must be serviced as a first priority. In this presentation, a review of the main concepts related to the electrical safety in health area,theinternational standard, the distribution of electric power in hospital and protection against shockwill be introduced. Protection system in hospital will be presented in its two ways: inpower distribution in hospitaland inbiomedical equipment design,finally the optimum maintenance technology and safety tests in health care areawill presented also.

  13. DNA repair deficiency in neurodegeneration

    DEFF Research Database (Denmark)

    Jeppesen, Dennis Kjølhede; Bohr, Vilhelm A; Stevnsner, Tinna V.

    2011-01-01

    Deficiency in repair of nuclear and mitochondrial DNA damage has been linked to several neurodegenerative disorders. Many recent experimental results indicate that the post-mitotic neurons are particularly prone to accumulation of unrepaired DNA lesions potentially leading to progressive...... neurodegeneration. Nucleotide excision repair is the cellular pathway responsible for removing helix-distorting DNA damage and deficiency in such repair is found in a number of diseases with neurodegenerative phenotypes, including Xeroderma Pigmentosum and Cockayne syndrome. The main pathway for repairing oxidative...... base lesions is base excision repair, and such repair is crucial for neurons given their high rates of oxygen metabolism. Mismatch repair corrects base mispairs generated during replication and evidence indicates that oxidative DNA damage can cause this pathway to expand trinucleotide repeats, thereby...

  14. Improvement of adhesion performance of mortar-repair interface with inducing crack path into repair

    Directory of Open Access Journals (Sweden)

    A. Satoh

    2015-10-01

    Full Text Available The most important performance for repair materials is adhesion to the substrate. The authors experimentally find out that high modulus fine aggregates in repair material enhance strength of it as well as the strength of the interface repaired with it, compared to the ordinary repair without fine aggregates. This paper elaborates the mechanisms for that with fractographic observation and FEM analysis based on the results of experiment. Also the authors discuss the ways for enhancing the strength and ductility of the repaired mortar

  15. [Demography perspectives and forecasts of the demand for electricity].

    Science.gov (United States)

    Roy, L; Guimond, E

    1995-01-01

    "Demographic perspectives form an integral part in the development of electric load forecasts. These forecasts in turn are used to justify the addition and repair of generating facilities that will supply power in the coming decades. The goal of this article is to present how demographic perspectives are incorporated into the electric load forecasting in Quebec. The first part presents the methods, hypotheses and results of population and household projections used by Hydro-Quebec in updating its latest development plan. The second section demonstrates applications of such demographic projections for forecasting the electric load, with a focus on the residential sector." (SUMMARY IN ENG AND SPA) excerpt

  16. Electric and magnetic field measurements in an outdoor electric power substation

    Energy Technology Data Exchange (ETDEWEB)

    Safigianni, A.S.; Tsompanidou, C.G. [Democritus Univ. Thrace, Xanthi (Greece). Dept. of Electrical and Computer Engineering

    2006-07-01

    With the ever increasing environmental exposure to man-made electromagnetic fields (EMFs), public concern regarding the potential health hazards of exposure to electric and magnetic fields at extremely low frequencies (ELF) has also increased. This paper examined the ELF fields at a 150/20 kV outdoor electric power substation in Xanthi, Greece. Basic data regarding this substation was provided along with previous relevant research studies. The reference levels for safe general public and occupational exposure according to the International Commission on Non-Ionizing Radiation Protection (ICNIRP) was also presented. The instruments used to take the measurements were described and indicative results of the EMFs measurements in the substation were provided. In general, the measured magnetic flux density values were far below the reference level for safe public and occupational exposure. No significant differentiation was noted in these values in relation to body height. However, the levels were found to be in violation in two positions, near the capacitor banks. It was emphasized that these values greatly decreased with distance, and the positions where these high values were measured were not occupied by technicians when the capacitors were under voltage. In addition, it was emphasized that the measured magnetic flux density values were very small in the supervision room, where the supervisor of the substation works and in the ring zone where the public has access. All the measured electric field strength values were below the reference level for safe public and occupational exposure. It was concluded that the measured field values are within recognized guidelines and pose no danger for public or working personnel. 19 refs., 1 tab., 4 figs.

  17. Radiobiological significance of DNA repair

    International Nuclear Information System (INIS)

    Kuzin, A.M.

    1978-01-01

    A short outline is given on the history of the problem relating to the repair of radiation injuries, specifically its molecular mechanisms. The most urgent problems which currently confront the researchers are noted. This is a further study on the role of DNA repair in post-radiation recovery, search for ways to activate and suppress DNA repair, investigations into the activity balance of various repair enzymes as well as the problem of errors in the structure of repairing DNA. An important role is attached to the investigations of DNA repair in solving a number of practical problems

  18. Critical and subcritical damage monitoring of bonded composite repairs using innovative non-destructive techniques

    Science.gov (United States)

    Grammatikos, S. A.; Kordatos, E. Z.; Aggelis, D. G.; Matikas, T. E.; Paipetis, A. S.

    2012-04-01

    Infrared Thermography (IrT) has been shown to be capable of detecting and monitoring service induced damage of repair composite structures. Full-field imaging, along with portability are the primary benefits of the thermographic technique. On-line lock-in thermography has been reported to successfully monitor damage propagation or/and stress concentration in composite coupons, as mechanical stresses in structures induce heat concentration phenomena around flaws. During mechanical fatigue, cyclic loading plays the role of the heating source and this allows for critical and subcritical damage identification and monitoring using thermography. The Electrical Potential Change Technique (EPCT) is a new method for damage identification and monitoring during loading. The measurement of electrical potential changes at specific points of Carbon Fiber Reinforced Polymers (CFRPs) under load are reported to enable the monitoring of strain or/and damage accumulation. Along with the aforementioned techniques Finally, Acoustic Emission (AE) method is well known to provide information about the location and type of damage. Damage accumulation due to cyclic loading imposes differentiation of certain parameters of AE like duration and energy. Within the scope of this study, infrared thermography is employed along with AE and EPCT methods in order to assess the integrity of bonded repair patches on composite substrates and to monitor critical and subcritical damage induced by the mechanical loading. The combined methodologies were effective in identifying damage initiation and propagation of bonded composite repairs.

  19. The correlation between the use of personal protective equipment and level wild-type p53 of dental technicians in Surabaya

    Directory of Open Access Journals (Sweden)

    Puspa Dila Rohmaniar

    2017-03-01

    Full Text Available Background: Exposure of metals among dental technicians that come from the working environment can lead to the formation reactive oxygen species (ROS. ROS can cause mutations in the p53 gene (p53. The mutation is transversion mutation GuanineThymine. p53 mutations can lead to low expression of the wild-type p53 protein (p53. Wild-type p53 involved in many biological processes such as regulation of genes involved in cell cycle, cell growth after DNA damage, and apoptosis. However, exposure to metals among dental technicians can be prevented through the use of personal protective equipment (PPE during work. Purpose: The purpose of this study was to analyze the correlation between the use of personal protective equipment to wild-type p53 protein levels among dental technicians in Surabaya. Method: This study was observational analytic with cross sectional approach. 40 samples were taken by random sampling. Data were retrieved through interviews and observations. Wild-type p53 was analyzed from saliva with indirect ELISA method. Analysis of data used Kolmogorov Smirnov normality test and a Pearson correlation test. Value significance was p<0.05 (95% confidence level. Result: There was a significant association between the use of personal protective equipment with wild-type p53 levels with p=0.002 Conclusion: The use PPE properly is positively correlated with the wild-type p53 protein levels of dental technicians in Surabaya.

  20. Exposure to airborne organophosphates originating from hydraulic and turbine oils among aviation technicians and loaders.

    Science.gov (United States)

    Solbu, Kasper; Daae, Hanne Line; Thorud, Syvert; Ellingsen, Dag Gunnar; Lundanes, Elsa; Molander, Paal

    2010-12-01

    This study describes the potential for occupational exposure to organophosphates (OPs) originating from turbine and hydraulic oils, among ground personnel within the aviation industry. The OPs tri-n-butyl phosphate (TnBP), dibutyl phenyl phosphate (DBPP), triphenyl phosphate (TPP) and tricresyl phosphate (TCP) have been emphasized due to their use in such oils. Oil aerosol/vapor and total volatile organic compounds (tVOCs) in air were also determined. In total, 228 and 182 OPs and oil aerosol/vapor samples from technician and loader work tasks during work on 42 and 21 aircrafts, respectively, were collected in pairs. In general, the measured exposure levels were below the limit of quantification (LOQ) for 84%/98% (oil aerosol) and 82%/90% (TCP) of the samples collected during technician/loader work tasks. The air concentration ranges for all samples related to technician work were

  1. DNA repair in neurons: So if they don't divide what's to repair?

    International Nuclear Information System (INIS)

    Fishel, Melissa L.; Vasko, Michael R.; Kelley, Mark R.

    2007-01-01

    Neuronal DNA repair remains one of the most exciting areas for investigation, particularly as a means to compare the DNA repair response in mitotic (cancer) vs. post-mitotic (neuronal) cells. In addition, the role of DNA repair in neuronal cell survival and response to aging and environmental insults is of particular interest. DNA damage caused by reactive oxygen species (ROS) such as generated by mitochondrial respiration includes altered bases, abasic sites, and single- and double-strand breaks which can be prevented by the DNA base excision repair (BER) pathway. Oxidative stress accumulates in the DNA of the human brain over time especially in the mitochondrial DNA (mtDNA) and is proposed to play a critical role in aging and in the pathogenesis of several neurological disorders including Parkinson's disease, ALS, and Alzheimer's diseases. Because DNA damage accumulates in the mtDNA more than nuclear DNA, there is increased interest in DNA repair pathways and the consequence of DNA damage in the mitochondria of neurons. The type of damage that is most likely to occur in neuronal cells is oxidative DNA damage which is primarily removed by the BER pathway. Following the notion that the bulk of neuronal DNA damage is acquired by oxidative DNA damage and ROS, the BER pathway is a likely area of focus for neuronal studies of DNA repair. BER variations in brain aging and pathology in various brain regions and tissues are presented. Therefore, the BER pathway is discussed in greater detail in this review than other repair pathways. Other repair pathways including direct reversal, nucleotide excision repair (NER), mismatch repair (MMR), homologous recombination and non-homologous end joining are also discussed. Finally, there is a growing interest in the role that DNA repair pathways play in the clinical arena as they relate to the neurotoxicity and neuropathy associated with cancer treatments. Among the numerous side effects of cancer treatments, major clinical effects

  2. Professional expectations of students of the oral health technician course

    Directory of Open Access Journals (Sweden)

    José Ferreira Lima Junior

    2012-03-01

    Full Text Available Objective: To identify the expectations of students enrolled in the oral health technician course conducted by the School of Public Health of Ceará, about their professional future. Methods:This work presents a quantitative, cross-sectional descriptive study held with students of seven classes in dental hygiene course conducted by the School of Public Health. Data collection was conducted between March and April 2011, through the application of a semistructured questionnaire, which addressed the professional profile of the participants, their expectations about the labor market and the profession. Statistical analysis was performedwith a degree of significance of 0.05. Results: 154 students were interviewed, of whom 96.1% were women, mean age of 32.9 (± 7.3 years. Most (93.8%, N = 120 graduated from high school and 71.1% (N = 108 were registered at the Regional Council of Dentistry. Regardingtheir insertion in the labor market, 42.9% believed it would be satisfactory and 58% that it would occur in public service. The biggest obstacle mentioned by the subjects about the insertion of oral health technicians in the labor market was the difficulty of hiring (45.5%. When asked to punctuate some actions that they would play as TSB, 82.2% cited clinical and collective actions. The majority (96% claimed to feel safe to act as TSB. Conclusion:The students’ expectations regarding their professional future are positive. However, it is necessary to develop further research in this area, so that the profession has a growing support within the labor market.

  3. The Validity of Subjects in Korean Dental Technicians' Licensing Examination

    Directory of Open Access Journals (Sweden)

    Woong-chul Kim

    2005-06-01

    Full Text Available This study prepared a basic framework for the development and improvement of Korean Dental Technicians' Licensing Examination, based on actual test questions. A peer review was conducted to ensure relevance to current practices in dental technology. For the statistical analysis, 1000 dental laboratory technicians were selected; specialists in dental laboratory technology (laboratory owners, educators, etc. were involved in creating valid and reliable questions. Results indicated that examination subjects should be divided into three categories: basic dental laboratory theory, dental laboratory specialties, and a practical examination. To ensure relevance to current practice, there should be less emphasis on basic dental laboratory theory, including health-related laws, and more emphasis on dental laboratory specialties. Introduction to dental anatomy should be separated from oral anatomy and tooth morphology; and fixed prosthodontics should be separated from crown and bridge technology and dental ceramics technology. Removable orthodontic appliance technology should be renamed 'orthodontic laboratory technology'. There should be less questions related to health related law, oral anatomy, dental hygiene, dental materials science and inlay, while the distribution ratio of questions related to tooth morphology should be maintained. There should be a decrease in the distribution ratio of questions related to crown and bridge technology, dental ceramics technology, complete dentures and removable partial dentures technology, and orthodontic laboratory technology. In the practical examination, the current multiple choice test should be replaced with tooth carving using wax or plaster. In dental laboratory specialties, subjects related to contemporary dental laboratory technology should be included in the test items.

  4. USING THE OUTSOURCING MECHANISM TO INCREASE THE EFFICIENCY OF REPAIR AND MAINTENANCE IN METALLURGICAL ENTERPRISES

    Directory of Open Access Journals (Sweden)

    Elena I. Kozlova

    2017-01-01

    Full Text Available Abstract. Objectives The aim of the work is to study the outsourcing mechanism from the point of view of increasing the efficiency of repair and maintenance at a metallurgical enterprise. Method Analysis of the experience of using outsourcing of repair services at domestic and foreign metallurgical enterprises was carried out. Analysis of the experience of the withdrawal from enterprise repair services into a separate outsourcing company has shown that the main advantages of this method of organising repair activities are an increase in the transparency of the costs of repairs and maintenance, and hence their reduction, as well as a reduction in the amount of equipment downtime. The main characteristics of outsourcing were revealed, substantiating its expediency. The restructuring of the repair system provides a step-by-step transition from decentralised to centralised structures of technical, mechanical, power and electrical repair services of enterprises, from the principle of "self-service" to the principle of "proprietary service" by isolating the subdivisions of the repair system from the structure of enterprises and creating competing members of the repair services market. Put another way, this is typified by moving away from the status of auxiliary production to a selfdependent activity. The stages of outsourcing the repair services of the enterprise are considered and possible problems that may arise in the course of the work of a working group are established to determine the suitability of outsourcing and to resolve the numerous issues arising from the transfer of repair functions. Results The findings of the research include approaches developed for overcoming risky situations: providing guarantees from the customer and the contractor and indicating them in the contract, increasing the motivation of the outsourcing company through a key performance indicator that should increase the interest of the performer in providing quality

  5. Occupational stress among nursing technicians and assistants: coping focused on the problem

    Directory of Open Access Journals (Sweden)

    Carla Araújo Bastos Teixeira

    2015-04-01

    Full Text Available Objective. To analyze the association between strategies used to cope with occupational stress that are focused on the problem wand the personal characteristics of nursing technicians and assistants. Methodology. This quantitative and correlational study was conducted in a large teaching hospital in the São Paulo State, Brazil, in 2013. A randomized sample with 310 participants (198 nursing assistants and 112 nursing technicians comprised the study population. Data were collected using a sociodemographic characteristics questionnaire and Scale of Ways of Coping with Problems. Data were submitted to univariate analysis, and variables with statistical significance (p<0.20 were submitted posteriorly in a multiple regression model. Results. Most employees were women (76.1% older than 40 years (67.7%, had nine to 11 years of formal education (73.5%, had a partner (58.7%, were Catholic (53.2%, and had children (74.5%. The final multiple regression model consisted of variable years of formal education and number of children. Conclusion. In this study, formal education and number of children were more strongly associated with a greater use of coping strategies focused on the problem. Such a strategy is related to minimal vulnerability to stress related to the working environment.

  6. Reward optimization of a repairable system

    International Nuclear Information System (INIS)

    Castro, I.T.; Perez-Ocon, R.

    2006-01-01

    This paper analyzes a system subject to repairable and non-repairable failures. Non-repairable failures lead to replacement of the system. Repairable failures, first lead to repair but they lead to replacement after a fixed number of repairs. Operating and repair times follow phase type distributions (PH-distributions) and the pattern of the operating times is modelled by a geometric process. In this context, the problem is to find the optimal number of repairs, which maximizes the long-run average reward per unit time. To this end, the optimal number is determined and it is obtained by efficient numerical procedures

  7. Reward optimization of a repairable system

    Energy Technology Data Exchange (ETDEWEB)

    Castro, I.T. [Departamento de Matematicas, Facultad de Veterinaria, Universidad de Extremadura, Avenida de la Universidad, s/n. 10071 Caceres (Spain)]. E-mail: inmatorres@unex.es; Perez-Ocon, R. [Departamento de Estadistica e Investigacion Operativa, Facultad de Ciencias, Universidad de Granada, Avenida de Severo Ochoa, s/n. 18071 Granada (Spain)]. E-mail: rperezo@ugr.es

    2006-03-15

    This paper analyzes a system subject to repairable and non-repairable failures. Non-repairable failures lead to replacement of the system. Repairable failures, first lead to repair but they lead to replacement after a fixed number of repairs. Operating and repair times follow phase type distributions (PH-distributions) and the pattern of the operating times is modelled by a geometric process. In this context, the problem is to find the optimal number of repairs, which maximizes the long-run average reward per unit time. To this end, the optimal number is determined and it is obtained by efficient numerical procedures.

  8. The role of Columbia Basin College in training technicians for environmental remediation at the DOE Hanford Site

    International Nuclear Information System (INIS)

    Ferrigno, K.F.

    1991-01-01

    Community colleges have the ability to play a vital role in the environmental remediation training process for DOE hazardous waste sites. Columbia Basin College in Pasco, Washington is presently involved in such training through numerous workshops offered primarily for employees at the Hanford DOE site, and a two-year associate of applied science degree in Hazardous Materials Management Technology. The workshops are oriented towards specific applied technical training (40 Hour OSHA/80 Hour WISHA, Hazardous/Radioactive Waste Video conference, and others) whereas the degree program provides a broad background in the skills needed for environmental technicians (16 hazmat courses plus support sciences and humanities). The degree program, combined with hazmat work experience, should provide the necessary background for project supervision as well as for skilled field technicians

  9. Medical Laboratory Technician--Microbiology, 10-3. Military Curriculum Materials for Vocational and Technical Education.

    Science.gov (United States)

    Ohio State Univ., Columbus. National Center for Research in Vocational Education.

    This course, the second of three courses in the medical laboratory technician field adapted from military curriculum materials for use in vocational and technical education, was designed as a refresher course for student self-study and evaluation. It is suitable for use by advanced students or beginning students participating in a supervised…

  10. Retinal detachment repair

    Science.gov (United States)

    ... medicines Problems breathing You may not recover full vision. ... detachments can be repaired. Failure to repair the retina always results in loss of vision to some degree. After surgery, the quality of ...

  11. KSC technician installs rows of experiment racks in IML-1 spacelab module

    Science.gov (United States)

    1991-01-01

    Kennedy Space Center (KSC) technician installs rows of experiment racks in the International Microgravity Laboratory 1 (IML-1) in the KSC Operations and Checkout (O and C) Bldg. The IML-1 is scheduled to fly on STS-42 in early 1992, and will turn the shuttle into a laboratory dedicated to investigating the effects of microgravity on materials and life processes. View provided by KSC with alternate number KSC-91P-169.

  12. A new incomplete-repair model based on a ''reciprocal-time'' pattern of sublethal damage repair

    International Nuclear Information System (INIS)

    Dale, R.G.; Fowler, J.F.

    1999-01-01

    A radiobiological model for closely spaced non-instantaneous radiation fractions is presented, based on the premise that the time process of sublethal damage (SLD) repair is 'reciprocal-time' (second order), rather than exponential (first order), in form. The initial clinical implications of such an incomplete-repair model are assessed. A previously derived linear-quadratic-based model was revised to take account of the possibility that SLD may repair with time such that the fraction of an element of initial damage remaining at time t is given as 1/(1+zt), where z is an appropriate rate constant; z is the reciprocal of the first half-time (τ) of repair. The general equation so derived for incomplete repair is applicable to all types of radiotherapy delivered at high, low and medium dose-rate in fractions delivered at regular time intervals. The model allows both the fraction duration and interfraction intervals to vary between zero and infinity. For any given value of z, reciprocal repair is associated with an apparent 'slowing-down' in the SLD repair rate as treatment proceeds. The instantaneous repair rates are not directly governed by total dose or dose per fraction, but are influenced by the treatment duration and individual fraction duration. Instantaneous repair rates of SLD appear to be slower towards the end of a continuous treatment, and are also slower following 'long' fractions than they are following 'short' fractions. The new model, with its single repair-rate parameter, is shown to be capable of providing a degree of quantitative explanation for some enigmas that have been encountered in clinical studies. A single-component reciprocal repair process provides an alternative explanation for the apparent existence of a range of repair rates in human tissues, and which have hitherto been explained by postulating the existence of a multi-exponential repair process. The build-up of SLD over extended treatments is greater than would be inferred using a

  13. How compliant are technicians with universal safety measures in medical laboratories in Croatia?--A pilot study.

    Science.gov (United States)

    Dukic, Kristina; Zoric, Matea; Pozaic, Petra; Starcic, Jelena; Culjak, Marija; Saracevic, Andrea; Miler, Marijana

    2015-01-01

    This pilot study aimed to investigate the use of personal protective equipment (PPE) and compliance to the code of conduct (rules defined in institutional, governmental and professional guidelines) among laboratory technicians in Croatian medical laboratories. In addition, we explored the differences in compliance between participants of different age groups, laboratory ownership and accreditation status. An anonymous and voluntary survey with 15 questions was conducted among Croatian medical laboratory technicians (N=217). The questions were divided into two groups: demographic characteristics and the use of PPE. The questions of the second part were graded according to the Likert scale (1-4) and an overall score, shown as median and range (min-max), was calculated for each participant. Differences between the overall scores were tested for each group of participants. The majority of participants always wear protective clothes at work, 38.7% of them always wear gloves in daily routine, more than 30.0% consume food and almost half of them drink beverages at workplace. A significantly lower overall score was found for participants working in public compared to private laboratories (36 (16-40) vs. 40 (31-40), Plaboratory accreditation status (P=0.081). A considerable percentage of laboratory technicians in Croatian medical laboratories do not comply with safety measures. Lack of compliance is observed in all personnel regardless laboratory accreditation and participants' age. However, those working in private laboratories adhere more to the code of conduct.

  14. CrowdAidRepair: A Crowd-Aided Interactive Data Repairing Method

    KAUST Repository

    Zhou, Jian; Li, Zhixu; Gu, Binbin; Xie, Qing; Zhu, Jia; Zhang, Xiangliang; Li, Guoliang

    2016-01-01

    turn to use the power of crowd in data repairing, but the crowd power has its own drawbacks such as high human intervention cost and inevitable low efficiency. In this paper, we propose a crowd-aided interactive data repairing method which takes

  15. Time to pregnancy among Danish laboratory technicians who were a part of the National Birth Cohort

    DEFF Research Database (Denmark)

    Zhu, Jin Liang; Knudsen, Lisbeth E; Andersen, Anne-Marie Nybo

    2005-01-01

    OBJECTIVES: The Danish National Birth Cohort was used to examine whether laboratory work was associated with reduced fecundity. METHODS: Self-reported data on laboratory work and waiting time to pregnancy (0-2, 3-5, 6-12 and > 12 months) were used for 829 female laboratory technicians interviewed...... in 1997-2003. Altogether 6250 female teachers formed the reference group. A discrete-time survival analysis with a complementary log-log link was applied to estimate the fecundability ratio between the exposed and unexposed women, with adjustment for maternal age, gravidity, smoking, prepregnancy body......) 0.86-1.02] for all pregnancies and 0.98 (95% CI 0.86-1.13) for first pregnancies. A healthy worker effect was found for the laboratory technicians working with the work processes under study. CONCLUSIONS: The results do not suggest that laboratory work in Denmark at present impairs female fecundity....

  16. Complex networks under dynamic repair model

    Science.gov (United States)

    Chaoqi, Fu; Ying, Wang; Kun, Zhao; Yangjun, Gao

    2018-01-01

    Invulnerability is not the only factor of importance when considering complex networks' security. It is also critical to have an effective and reasonable repair strategy. Existing research on network repair is confined to the static model. The dynamic model makes better use of the redundant capacity of repaired nodes and repairs the damaged network more efficiently than the static model; however, the dynamic repair model is complex and polytropic. In this paper, we construct a dynamic repair model and systematically describe the energy-transfer relationships between nodes in the repair process of the failure network. Nodes are divided into three types, corresponding to three structures. We find that the strong coupling structure is responsible for secondary failure of the repaired nodes and propose an algorithm that can select the most suitable targets (nodes or links) to repair the failure network with minimal cost. Two types of repair strategies are identified, with different effects under the two energy-transfer rules. The research results enable a more flexible approach to network repair.

  17. Prioritising Progression over Proficiency: Limitations of Teacher-Based Assessment within Technician-Level Vocational Education

    Science.gov (United States)

    Carter, Alan; Bathmaker, Ann-Marie

    2017-01-01

    This article examines the evolution of assessment policy and practice in technician-level vocational education. Using the example of an advanced-level BTEC National programme in Engineering in one college in the UK, the article highlights how the origins of current assessment practice lie in genuine concerns since the late 1950s about the…

  18. How Technicians Can Lead Science Improvements in Any School: A Small-Scale Study in England

    Science.gov (United States)

    Jones, Beth; Quinnell, Simon

    2015-01-01

    This article describes how seven schools in England improved their science provision by focusing on the professional development of their science technicians. In September 2013, the Gatsby Charitable Foundation funded the National Science Learning Centre to lead a project connecting secondary schools with experienced senior science technicians…

  19. Harnessing the potential of biomaterials for brain repair after stroke

    Science.gov (United States)

    Tuladhar, Anup; Payne, Samantha L.; Shoichet, Molly S.

    2018-03-01

    Stroke is a devastating disease for which no clinical treatment exists to regenerate lost tissue. Strategies for brain repair in animal models of stroke include the delivery of drug or cell-based therapeutics; however, the complex anatomy and functional organization of the brain presents many challenges. Biomaterials may alleviate some of these challenges by providing a scaffold, localizing the therapy to the site of action, and/or modulating cues to brain cells. Here, the challenges associated with delivery of therapeutics to the brain and the biomaterial strategies used to overcome these challenges are described. For example, innovative hydrogel delivery systems have been designed to provide sustained trophic factor delivery for endogenous repair and to support transplanted cell survival and integration. Novel treatments, such as electrical stimulation of transplanted cells and the delivery of factors for the direct reprogramming of astrocytes into neurons, may be further enhanced by biomaterial delivery systems. Ultimately, improved clinical translation will be achieved by combining clinically relevant therapies with biomaterials strategies.

  20. Electrical Stimulation to Enhance Axon Regeneration After Peripheral Nerve Injuries in Animal Models and Humans.

    Science.gov (United States)

    Gordon, Tessa

    2016-04-01

    Injured peripheral nerves regenerate their lost axons but functional recovery in humans is frequently disappointing. This is so particularly when injuries require regeneration over long distances and/or over long time periods. Fat replacement of chronically denervated muscles, a commonly accepted explanation, does not account for poor functional recovery. Rather, the basis for the poor nerve regeneration is the transient expression of growth-associated genes that accounts for declining regenerative capacity of neurons and the regenerative support of Schwann cells over time. Brief low-frequency electrical stimulation accelerates motor and sensory axon outgrowth across injury sites that, even after delayed surgical repair of injured nerves in animal models and patients, enhances nerve regeneration and target reinnervation. The stimulation elevates neuronal cyclic adenosine monophosphate and, in turn, the expression of neurotrophic factors and other growth-associated genes, including cytoskeletal proteins. Electrical stimulation of denervated muscles immediately after nerve transection and surgical repair also accelerates muscle reinnervation but, at this time, how the daily requirement of long-duration electrical pulses can be delivered to muscles remains a practical issue prior to translation to patients. Finally, the technique of inserting autologous nerve grafts that bridge between a donor nerve and an adjacent recipient denervated nerve stump significantly improves nerve regeneration after delayed nerve repair, the donor nerves sustaining the capacity of the denervated Schwann cells to support nerve regeneration. These reviewed methods to promote nerve regeneration and, in turn, to enhance functional recovery after nerve injury and surgical repair are sufficiently promising for early translation to the clinic.

  1. A technician works adjacent to the Apollo 11 spacecraft atop the white room.

    Science.gov (United States)

    1969-01-01

    A technician can be seen working atop the white room across from the escape tower of the Apollo 11 spacecraft a few days prior to the launch of the Saturn V moon rocket. The towering 363-foot Saturn V was a multi-stage, multi-engine launch vehicle standing taller than the Statue of Liberty. Altogether, the Saturn V engines produced as much power as 85 Hoover Dams

  2. 49 CFR 1242.42 - Administration, repair and maintenance, machinery repair, equipment damaged, dismantling retired...

    Science.gov (United States)

    2010-10-01

    ... repair, equipment damaged, dismantling retired property, fringe benefits, other casualties and insurance, lease rentals, joint facility rents, other rents, depreciation, joint facility, repairs billed to others... maintenance, machinery repair, equipment damaged, dismantling retired property, fringe benefits, other...

  3. Document management training for managers and technicians of municipal institutions files

    Directory of Open Access Journals (Sweden)

    Ana María Barrial Martínez

    2017-07-01

    Full Text Available The objective analysis of the permanent formation of human resources requires not departing from the present conditions in which the world develops, where the progress of neoliberal policies, globalization and the vertiginous advance of the scientific-technical and technological revolution demands that the training of Professionals, is subject to continuous transformation. This article responds to the need to increase the preparation of file managers and technicians of the municipal institutions of Pinar del Rio, from the perfection of the training process in documentary management, which allows them to develop archival skills in their professional performance. It explains theoretical and conceptual considerations that allow to understand the significance of the training of these subjects as a strategic factor in the labor entities, as well as to refer to the existing trends in the national scope, based on the study and assessment of literature related to the theme, which can contribute to the design and implementation of training alternatives, according to the characteristics and particularities of the context in which they are used. The training of professionals is a process that is an essential way to increase the preparation in document management of the managers and architects of the institutions for their professional performance. The Cuban experience in the preparation and training of archival managers and technicians has shown, from a trend analysis that it is possible the development of archival skills in their professional performance, as long as the

  4. Collision Repair Campaign

    Science.gov (United States)

    The Collision Repair Campaign targets meaningful risk reduction in the Collision Repair source category to reduce air toxic emissions in their communities. The Campaign also helps shops to work towards early compliance with the Auto Body Rule.

  5. Repair mechanisms and exposure standards

    International Nuclear Information System (INIS)

    Mills, W.A.

    1978-01-01

    The following topics are discussed; public policy for setting radiation standards; use of linear, nonthreshold theory in setting radiation standards; dose-rate dependence; occupational exposure to radiation; radon inhalation from radium in the soil in the vicinity of the phosphate industry; relation of repair mechanisms for cell survival to cancer induction; application of information on genetic repair to humans and to cancer induction; importance of repair processes in radiation protection standards; corrective factors for repair processes; relation of repair processes to age, sex, and other factors; and population distribution in radiosensitivity

  6. Knowledge, attitude, and practice (KAP) of 'teaching laboratory' technicians towards laboratory safety and waste management: a pilot interventional study.

    Science.gov (United States)

    El-Gilany, A-H; El-Shaer, S; Khashaba, E; El-Dakroory, S A; Omar, N

    2017-06-01

    A quasi-experimental study was performed on 20 technicians working in the Faculty of Medicine, Mansoura University, Egypt. The knowledge, attitude, and practice (KAP) of laboratory technicians was measured before and two months after enrolling them in an intervention programme about laboratory best practice procedures. The programme addressed laboratory safety and medical waste management. The assessment was performed using a validated Arabic self-administered questionnaire. Pre- and post-intervention scores were compared using non-parametric tests. There are significant increases in the scores of KAP after implementation of the training programme. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  7. Laparoscopic repair of postoperative perineal hernia.

    LENUS (Irish Health Repository)

    Ryan, Stephen

    2010-01-01

    Perineal hernias are infrequent complications following abdominoperineal operations. Various approaches have been described for repair of perineal hernias including open transabdominal, transperineal or combined abdominoperineal repairs. The use of laparoscopic transabdominal repair of perineal hernias is not well-described. We present a case report demonstrating the benefits of laparoscopic repair of perineal hernia following previous laparoscopic abdominoperineal resection (APR) using a nonabsorbable mesh to repair the defect. We have demonstrated that the use of laparoscopy with repair of the pelvic floor defect using a non absorbable synthetic mesh offers an excellent alternative with many potential advantages over open transabdominal and transperineal repairs.

  8. Transfer of Chinese hamster DNA repair gene(s) into repair-deficient human cells (Xeroderma pigmentosum)

    International Nuclear Information System (INIS)

    Karentz, D.; Cleaver, J.E.

    1985-01-01

    Transfer of repair genes by DNA transfection into repair-deficient Xeroderma pigmentosum (XP) cells has thus far been unsuccessful, presenting an obstacle to cloning XP genes. The authors chose an indirect route to transfer repair genes in chromosome fragments. DNA repair-competent (UV resistant) hybrid cell lines were established by PEG-mediated fusions of DNA repair-deficient (UV sensitive) human fibroblasts (XP12RO) with wild type Chinese hamster (CHO) cells (AA8). CHO cells were exposed to 5 Krad X-rays prior to fusions, predisposing hybrid cells to lose CHO chromosome fragments preferentially. Repair-competent hybrids were selected by periodic exposures to UV light. Secondary and tertiary hybrid cell lines were developed by fusion of X-irradiated hybrids to XP12RO. The hybrid cell lines exhibit resistance to UV that is comparable to that of CHO cells and they are proficient at repair replication after UV exposure. Whole cell DNA-DNA hybridizations indicate that the hybrids have greater homology to CHO DNA than is evident between XP12RO and CHO. These observations indicate that CHO DNA sequences which can function in repair of UV-damaged DNA in human cells have been transferred into the genome of the repair-deficient XP12RO cells

  9. Electric Vehicle Service Personnel Training Program

    Energy Technology Data Exchange (ETDEWEB)

    Bernstein, Gerald

    2013-06-21

    As the share of hybrid, plug-in hybrid (PHEV), electric (EV) and fuel-cell (FCV) vehicles grows in the national automotive fleet, an entirely new set of diagnostic and technical skills needs to be obtained by the maintenance workforce. Electrically-powered vehicles require new diagnostic tools, technique and vocabulary when compared to existing internal combustion engine-powered models. While the manufacturers of these new vehicles train their own maintenance personnel, training for students, independent working technicians and fleet operators is less focused and organized. This DOE-funded effort provided training to these three target groups to help expand availability of skills and to provide more competition (and lower consumer cost) in the maintenance of these hybrid- and electric-powered vehicles. Our approach was to start locally in the San Francisco Bay Area, one of the densest markets in the United States for these types of automobiles. We then expanded training to the Los Angeles area and then out-of-state to identify what types of curriculum was appropriate and what types of problems were encountered as training was disseminated. The fact that this effort trained up to 800 individuals with sessions varying from 2- day workshops to full-semester courses is considered a successful outcome. Diverse programs were developed to match unique time availability and educational needs of each of the three target audiences. Several key findings and observations arising from this effort include: • Recognition that hybrid and PHEV training demand is immediate; demand for EV training is starting to emerge; while demand for FCV training is still over the horizon • Hybrid and PHEV training are an excellent starting point for all EV-related training as they introduce all the basic concepts (electric motors, battery management, controllers, vocabulary, testing techniques) that are needed for all EVs, and these skills are in-demand in today’s market. • Faculty

  10. Potentially damaging failure modes of high- and medium-voltage electrical equipment

    International Nuclear Information System (INIS)

    Hoy, H.C.

    1983-07-01

    The electrical equipment failures of both nuclear and nonnuclear public utilities were reviewed. Those failures that could pose an additional problem to surrounding and connected equipment were defined. The literature was searched; utilities, repair shops, and large electrical equipment users were contacted for failure information. The data were reviewed in detail, and failure modes were determined. Sample cascade failures are discussed. The failure rate of electrical equipment in utilities is historically quite low. Nuclear plants record too few failures to be statistically valid, but failures that have been recorded show that good design usually restricts the failure to a single piece of equipment

  11. NASDA technician test real-time radiation monitoring device

    Science.gov (United States)

    1997-01-01

    A technician from the National Space Development Agency of Japan (NASDA) tests the real-time radiation monitoring device on SPACEHAB at Kennedy Space Center in preparation for the STS-89 mission, slated to be the first Shuttle launch of 1998. STS-89 will be the eighth of nine scheduled Mir dockings and will include a double module of SPACEHAB, used mainly as a large pressurized cargo container for science, logistical equipment and supplies to be exchanged between the orbiter Endeavour and the Russian Space Station Mir. The nine-day flight of STS-89 also is scheduled to include the transfer of the seventh American to live and work aboard the Russian orbiting outpost. Liftoff of Endeavour and its seven-member crew is targeted for Jan. 15, 1998, at 1:03 a.m. EDT from Launch Pad 39A.

  12. Healing of cornea following an electric burn.

    Science.gov (United States)

    Chaudhry, Tanveer Anjum; Shaikh, Farheen; Ahmad, Khabir

    2012-08-01

    Electrical injuries have become a significant health problem in developing countries because of increase in access to electricity in the last few decades and lack of adequate safety measures. Electrical injuries of eyes are relatively uncommon. A case report of a rapid and complete corneal healing accompanied by satisfactory visual recovery after an electric burn event in a 20-year-old male is reported. The patient had accidental exposure to high voltage live wire while he was repairing it, resulting in severe ocular and superficial body burn. He was not wearing any protective equipment at the time of injury. On examination, the best-corrected visual acuity was counting fingers in the left eye with severe corneal epithelial loss and diffuse corneal oedema. The patient was treated medically, with a rapid corneal healing and resolution of oedema over the next few days. Visual acuity in the worse eye (left) improved to 20/25 from counting fingers.

  13. Annual report of the group for maintenance of electrical equipment; Godisnji izvestaj elektro grupe

    Energy Technology Data Exchange (ETDEWEB)

    Rajic, M [Odelenje odrzavanja, Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Serbia and Montenegro)

    1965-12-15

    This report includes detailed description of repairs and revisions of the electrical equipment of the RA reactor which were done according to the annual plan during the periods when reactor was not operated. Unplanned repairs are part of this report as well. [Serbo-Croat] Ovaj izvestaj sadrzi detaljan opis remontnih i revizionih radova na elektroopremi reaktora RA izvrsenih prema godisnjem planu u periodima kada reaktor nije radio. Vanplanski poslovi ukljucujuci popravke elektroopreme su takodje deo ovog izvestaja.

  14. Case study : a transformer repair facility

    Energy Technology Data Exchange (ETDEWEB)

    Jerade, L. [Jacques Whitford Environment Ltd., Vancouver, BC (Canada)

    2006-07-01

    Polychlorinated biphenyls (PCBs) are synthetic chemical compounds consisting of chlorine, carbon and hydrogen. They are very stable, fire resistant, do not conduct electricity and have low volatility at normal temperatures. They were mainly used as a cooling and insulating fluid for industrial transformers and capacitors. Some of the same properties that made PCBs so widely used, also make them environmentally hazardous, especially their extreme resistance to chemical and biological breakdown by natural processes in the environment. Typical chemicals associated with the presence of PCB oils are chlorobenzene, lead, xylene, and petroleum hydrocarbons. A case study of a transformer repair facility was discussed along with its soil and groundwater remediation. This presentation discussed the delineation program for the site which operated as a repair facility of PCB-containing transformers from 1968 until 1998. The property was bought by Siemens Canada Ltd. in 1998 and was sold in 2004. As part of the purchasing agreement, a Certificate of Compliance from the British Columbia Ministry of Environment was required. Remediation work was therefore needed. The presentation also covered: zones of contamination and contaminants of concern, soil impacts, groundwater impacts, and an evaluation of remediation options. In-situ treatment of soil with hydrogen peroxide and the selected remedial option were discussed. A soil economic analysis was also conducted. Last, challenges, solutions, and conclusions were presented. tabs., figs.

  15. Aging and DNA repair capability. [Review

    Energy Technology Data Exchange (ETDEWEB)

    Tice, R R

    1977-01-01

    A review of the literature on DNA repair processes in relation to aging is presented under the following headings: DNA repair processes; age-related occurrence of unrepaired DNA lesions; DNA repair capability as a function of age; tissue-specific DNA repair capability; acceleration of the aging process by exposure to DNA damaging agents; human genetic syndromes; and longevity and DNA repair processes. (HLW)

  16. Bentonite electrical conductivity: a model based on series–parallel transport

    KAUST Repository

    Lima, Ana T.

    2010-01-30

    Bentonite has significant applications nowadays, among them as landfill liners, in concrete industry as a repairing material, and as drilling mud in oil well construction. The application of an electric field to such perimeters is under wide discussion, and subject of many studies. However, to understand the behaviour of such an expansive and plastic material under the influence of an electric field, the perception of its electrical properties is essential. This work serves to compare existing data of such electrical behaviour with new laboratorial results. Electrical conductivity is a pertinent parameter since it indicates how much a material is prone to conduct electricity. In the current study, total conductivity of a compacted porous medium was established to be dependent upon density of the bentonite plug. Therefore, surface conductivity was addressed and a series-parallel transport model used to quantify/predict the total conductivity of the system. © The Author(s) 2010.

  17. Repair of UV-irradiated plasmid DNA in excision repair deficient mutants of Saccharomyces cerevisiae

    International Nuclear Information System (INIS)

    Ikai, K.; Tano, K.; Ohnishi, T.; Nozu, K.

    1985-01-01

    The repair of UV-irradiated DNA of plasmid YEp13 was studied in the incision defective strains by measurement of cell transformation frequency. In Saccharomyces cerevisiae, rad1,2,3 and 4 mutants could repair UV-damaged plasmid DNA. In Escherichia coli, uvrA mutant was unable to repair UV-damaged plasmid DNA; however, pretreatment of the plasmid with Micrococcus luteus endonuclease increased repair. It was concluded that all the mutations of yeast were probably limited only to the nuclear DNA. (author)

  18. Effect of individually tailored biopsychosocial workplace interventions on chronic musculoskeletal pain, stress and work ability among laboratory technicians

    DEFF Research Database (Denmark)

    Jay, Kenneth; Petersen, Mikkel Brandt; Sundstrup, Emil

    2014-01-01

    control and may result in extended periods of time spent in static positions.In populations characterized by intense chronic musculoskeletal pain and diagnosed conditions in conjunction with psycho-physiological symptoms such as stress-related pain and soreness and other disabling conditions...... biopsychosocial intervention strategy on musculoskeletal pain, stress and work disability in lab technicians with a history of musculoskeletal pain at a single worksite in Denmark. METHODS/DESIGN: In this single-blind two-armed parallel-group randomized controlled trial with allocation concealment, participants......BACKGROUND: Among laboratory technicians, the prevalence of neck and shoulder pain is widespread possibly due to typical daily work tasks such as pipetting, preparing vial samples for analysis, and data processing on a computer including mouse work - all tasks that require precision in motor...

  19. DNA repair in Mycobacterium tuberculosis revisited.

    Science.gov (United States)

    Dos Vultos, Tiago; Mestre, Olga; Tonjum, Tone; Gicquel, Brigitte

    2009-05-01

    Our understanding of Mycobacterium tuberculosis DNA repair mechanisms is still poor compared with that of other bacterial organisms. However, the publication of the first complete M. tuberculosis genome sequence 10 years ago boosted the study of DNA repair systems in this organism. A first step in the elucidation of M. tuberculosis DNA repair mechanisms was taken by Mizrahi and Andersen, who identified homologs of genes involved in the reversal or repair of DNA damage in Escherichia coli and related organisms. Genes required for nucleotide excision repair, base excision repair, recombination, and SOS repair and mutagenesis were identified. Notably, no homologs of genes involved in mismatch repair were identified. Novel characteristics of the M. tuberculosis DNA repair machinery have been found over the last decade, such as nonhomologous end joining, the presence of Mpg, ERCC3 and Hlr - proteins previously presumed to be produced exclusively in mammalian cells - and the recently discovered bifunctional dCTP deaminase:dUTPase. The study of these systems is important to develop therapeutic agents that can counteract M. tuberculosis evolutionary changes and to prevent adaptive events resulting in antibiotic resistance. This review summarizes our current understanding of the M. tuberculosis DNA repair system.

  20. Privatization of Electricity Service Delivery in Developing Nations: Issues and Challenges

    Directory of Open Access Journals (Sweden)

    Olamide Eniola Victor

    2015-09-01

    Full Text Available The provision of public utilities and infrastructures particularly electricity by the public sector (Government especially in the Developing Nations has been heavily criticized. This has been attributed to many reasons including poor electricity supply, poor distribution of service delivery of electricity due to the absence of spatial planning, insufficient government investment into the power industry, ineptitude operation on the part of the technicians, poor administration and managerial control. However, efforts to move away from government ownership, control or participation in this sector of economy towards free enterprise and increased inclusive private sector participation known as privatization, has been adopted as one of the solutions. This paper presents a critical review of privatization practices of alternative Service Delivery approach of selected Asian and African nations. The paper would elicit the common variants of privatization models adopted by these nations and the different implementation strategies which resulted in divergence in effectiveness and efficiency in the service delivery of electricity. The selected Asian countries are; Malaysia, India, and China, while the selected African nations are Nigeria, Cameroun and South Africa. The paper will draw from the literatures the various approaches, concepts adopted, practices, issues and challenges faced by these countries.

  1. Electrical stimulation of schwann cells promotes sustained increases in neurite outgrowth.

    Science.gov (United States)

    Koppes, Abigail N; Nordberg, Andrea L; Paolillo, Gina M; Goodsell, Nicole M; Darwish, Haley A; Zhang, Linxia; Thompson, Deanna M

    2014-02-01

    Endogenous electric fields are instructive during embryogenesis by acting to direct cell migration, and postnatally, they can promote axonal growth after injury (McCaig 1991, Al-Majed 2000). However, the mechanisms for these changes are not well understood. Application of an appropriate electrical stimulus may increase the rate and success of nerve repair by directly promoting axonal growth. Previously, DC electrical stimulation at 50 mV/mm (1 mA, 8 h duration) was shown to promote neurite outgrowth and a more pronounced effect was observed if both peripheral glia (Schwann cells) and neurons were co-stimulated. If electrical stimulation is delivered to an injury site, both the neurons and all resident non-neuronal cells [e.g., Schwann cells, endothelial cells, fibroblasts] will be treated and this biophysical stimuli can influence axonal growth directly or indirectly via changes to the resident, non-neuronal cells. In this work, non-neuronal cells were electrically stimulated, and changes in morphology and neuro-supportive cells were evaluated. Schwann cell response (morphology and orientation) was examined after an 8 h stimulation over a range of DC fields (0-200 mV/mm, DC 1 mA), and changes in orientation were observed. Electrically prestimulating Schwann cells (50 mV/mm) promoted 30% more neurite outgrowth relative to co-stimulating both Schwann cells with neurons, suggesting that electrical stimulation modifies Schwann cell phenotype. Conditioned medium from the electrically prestimulated Schwann cells promoted a 20% increase in total neurite outgrowth and was sustained for 72 h poststimulation. An 11-fold increase in nerve growth factor but not brain-derived neurotrophic factor or glial-derived growth factor was found in the electrically prestimulated Schwann cell-conditioned medium. No significant changes in fibroblast or endothelial morphology and neuro-supportive behavior were observed poststimulation. Electrical stimulation is widely used in

  2. Repair-modification of radiodamaged genes

    International Nuclear Information System (INIS)

    Volpe, P.; Institute of Experimental Medicine, Rome; Eremenko, T.

    1995-01-01

    It is proposed that through repair-modification, the modified base 5mC may have facilitated the divergent evolution of coding (hypomethylated exon) and uncoding (hypermethylated promoter and intron) sequences in eukaryotic genes. The radioinduced repair patches appearing in regions lacking 5mC are fully reconstructed by excision-repair, whereas those appearing in regions containing 5mC are incompletely reconstructed by this conventional mechanism. Such a second class of repair patches may, however, become fully reconstructed, in the S phase, by repair-modification. In fact, while DNA polymerase β - which is a key enzyme of excision-repair - is active through the whole interphase. DNA methylase - which is responsible for post-synthetic DNA modification - is essentially active in S. Uncoupling of these two enzyme systems, outside S, might explain why in unsynchronised cells repair patches of non-replicating strands are hypomethylated when compared with specific methylation of replicating strands. In other words, excision-repair would always be able to re-establish the primary ATGC language of both damaged unmethylated and methylated regions, while repair-modification would be able to re-establish the modified ATGC(5mC) language of the damaged methylated regions, only in S, but not in G 1 or G 2 . In these two phases, when DNA methylation is inversely correlated with pre-mRNA transcription (as in the case of many tissue-specific genes), such demethylation might induce a silent transcriptional unit to become active. (Author)

  3. Lasting effects of workplace strength training for neck/shoulder/arm pain among laboratory technicians

    DEFF Research Database (Denmark)

    Mortensen, Peter; Larsen, Anders I; Zebis, Mette Kreutzfeldt

    2014-01-01

    Objectives. This study investigated long-term effects and implementation processes of workplace strength training for musculoskeletal disorders. Methods. 333 and 140 laboratory technicians from private and public sector companies, respectively, replied to a 3-year follow-up questionnaire subseque...... be implemented successfully at different companies during working hours on a long-term basis with lasting effects on pain in neck, shoulder, and arm....

  4. Prevalence and associated factors of job-related depression in laboratory technicians in Hospital Universiti Sains Malaysia (HUSM) and Ministry of Health Malaysia (MOH) Hospitals in Kelantan.

    Science.gov (United States)

    Aziah, B D; Rusli, B N; Winn, T; Naing, L; Tengku, M A

    2004-06-01

    Karasek's job strain model postulates that workers chronically exposed to adverse psychosocial work environment (high strain job)--high psychological job demands and low job control, including poor social support, increased physical demand and hazardous work condition--will eventually develop both physical illnesses such as cardiovascular diseases and psychological disorders such as depression. In order to determine the prevalence and associated factors of job-related depression, a cross-sectional study was conducted among laboratory technicians in Hospital Universiti Sains Malaysia (HUSM) and Kementerian Kesihatan Malaysia (KKM) Hospitals in Kelantan between September 2001 and February 2002. One hundred and two laboratory technicians in HUSM and 79 laboratory technicians in 7 KKM Hospitals were selected; 84/102 (82.4%) in HUSM and 71/79 (89.9%) in KKM Hospitals responded. Data was collected using self-administered questionnaires of the validated Malay version of the Job Content Questionnaire (JCQ) originally developed by Robert Karasek. Results indicated that the prevalence of high job strain in laboratory technicians in HUSM and KKM hospitals was 33.3% (28/84) and 26.8% (19/71), respectively (p>0.05). Significantly higher proportion (59.5%) (50/84) of laboratory technicians in HUSM compared to those in KKM Hospitals (39.4%) (28/71) (p = 0.016) experienced job-related depression. Significant associated factors of job-related depression were low social support (HUSM: adjusted OR 4.7, 95% CI 1.2-18.8; KKM: adjusted OR 14.8, 95%CI 2.4-89.3), high psychological demand (HUSM: adjusted OR 3.0, 95%CI 1.0-8.8), and low decision authority (KKM: adjusted OR 9.7, 95%CI 1.0-91.1). We conclude that strengthening the social support network (supervisors' and coworkers' support), reducing psychological job demand, and increasing decision-making authority of laboratory technicians may go a long way towards reducing job-related depression.

  5. Repair promoted by plasmid pKM101 is different from SOS repair

    International Nuclear Information System (INIS)

    Goze, A.; Devoret, R.

    1979-01-01

    In E. coli K12 bacteria carrying plasmid pKM101, prophage lambda was induced at UV doses higher than in plasmid-less parental bacteria. UV-induced reactivation per se was less effective. Bacteria with pKM101 showed no alteration in their division cycle. Plasmid PKM101 coded for a constitutive error-prone repair different from the inducible error-prone repair called SOS repair. Plasmid pKM101 protected E. coli bacteria from UV damage but slightly sensitized them to X-ray lesions. Protection against UV damage was effective in mutant bacteria deficient in DNA excision-repair provided that the recA, lexA and uvrE genes were functional. Survival of phages lambda and S13 after UV irradiation was enhanced in bacteria carrying plasmid pKM101; phage lambda mutagenesis was also increased. Plasmid pKM101 repaired potentially lethal DNA lesions, although Wild-type DNA sequences may not necessarily be restored; hence the mutations observed are the traces of the original DNA lesions. (Auth.)

  6. Comparative Assessment of Blood Lead Levels of Automobile Technicians in Organised and Roadside Garages in Lagos, Nigeria

    Directory of Open Access Journals (Sweden)

    Abdulsalam Saliu

    2015-01-01

    Full Text Available Occupational exposure to lead is common among automobile technicians and constitutes 0.9% of total global health burden with a majority of cases in developing countries. The aim of this study was to determine and compare the blood lead levels of automobile technicians in roadside and organised garages in Lagos State, Nigeria. This was a comparative cross-sectional study. Data were collected using interviewer-administered questionnaires. Physical examinations were conducted and blood was analysed for lead using atomic spectrophotometery. Statistical analyses were performed to compare the median blood lead levels of each group using the independent sample (Mann-Whitney U test. Seventy-three (40.3% of the organised compared to 59 (34.3% of the roadside groups had high blood lead levels. The organised group had statistically significant higher median blood lead levels of, 66.0 µg/dL than the roadside 43.5 µg/dL (P < 0.05. There was also statistically significant association between high blood lead levels and abnormal discolouration of the mucosa of the mouth in the organised group. Automobile technicians in organised garages in Lagos have higher prevalence of elevated blood lead levels and higher median levels than the roadside group. Preventive strategies against lead exposures should be instituted by the employers and further actions should be taken to minimize exposures, improve work practices, implement engineering controls (e.g., proper ventilation, and ensure the use of personal protective equipment.

  7. Cleft lip and palate repair

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/002979.htm Cleft lip and palate repair To use the sharing features on this ... Cheiloplasty; Cleft rhinoplasty; Palatoplasty; Tip rhinoplasty Patient Instructions Cleft lip and palate repair - discharge Images Cleft lip repair - series References ...

  8. 'Regular' and 'emergency' repair

    International Nuclear Information System (INIS)

    Luchnik, N.V.

    1975-01-01

    Experiments on the combined action of radiation and a DNA inhibitor using Crepis roots and on split-dose irradiation of human lymphocytes lead to the conclusion that there are two types of repair. The 'regular' repair takes place twice in each mitotic cycle and ensures the maintenance of genetic stability. The 'emergency' repair is induced at all stages of the mitotic cycle by high levels of injury. (author)

  9. Outbreak of hepatitis C virus infection associated with narcotics diversion by an hepatitis C virus–infected surgical technician

    Science.gov (United States)

    Warner, Amy E.; Schaefer, Melissa K.; Patel, Priti R.; Drobeniuc, Jan; Xia, Guoliang; Lin, Yulin; Khudyakov, Yury; Vonderwahl, Candace W.; Miller, Lisa; Thompson, Nicola D.

    2015-01-01

    Background Drug diversion by health care personnel poses a risk for serious patient harm. Public health identified 2 patients diagnosed with acute hepatitis C virus (HCV) infection who shared a common link with a hospital. Further investigation implicated a drug-diverting, HCV-infected surgical technician who was subsequently employed at an ambulatory surgical center. Methods Patients at the 2 facilities were offered testing for HCV infection if they were potentially exposed. Serum from the surgical technician and patients testing positive for HCV but without evidence of infection before their surgical procedure was further tested to determine HCV genotype and quasi-species sequences. Parenteral medication handling practices at the 2 facilities were evaluated. Results The 2 facilities notified 5970 patients of their possible exposure to HCV, 88% of whom were tested and had results reported to the state public health departments. Eighteen patients had HCV highly related to the surgical technician’s virus. The surgical technician gained unauthorized access to fentanyl owing to limitations in procedures for securing controlled substances. Conclusions Public health surveillance identified an outbreak of HCV infection due to an infected health care provider engaged in diversion of injectable narcotics. The investigation highlights the value of public health surveillance in identifying HCV outbreaks and uncovering a method of drug diversion and its impacts on patients. PMID:25442395

  10. When is cartilage repair successful?

    International Nuclear Information System (INIS)

    Raudner, M.; Roehrich, S.; Zalaudek, M.; Trattnig, S.; Schreiner, M.M.

    2017-01-01

    Focal cartilage lesions are a cause of long-term disability and morbidity. After cartilage repair, it is crucial to evaluate long-term progression or failure in a reproducible, standardized manner. This article provides an overview of the different cartilage repair procedures and important characteristics to look for in cartilage repair imaging. Specifics and pitfalls are pointed out alongside general aspects. After successful cartilage repair, a complete, but not hypertrophic filling of the defect is the primary criterion of treatment success. The repair tissue should also be completely integrated to the surrounding native cartilage. After some months, the transplants signal should be isointense compared to native cartilage. Complications like osteophytes, subchondral defects, cysts, adhesion and chronic bone marrow edema or joint effusion are common and have to be observed via follow-up. Radiological evaluation and interpretation of postoperative changes should always take the repair method into account. (orig.) [de

  11. Emergency Victim Care. A Training Manual for Emergency Medical Technicians. Module 5. CPR, Oxygen Therapy. Revised.

    Science.gov (United States)

    Ohio State Dept. of Education, Columbus. Div. of Vocational Education.

    This student manual, the fifth in a set of 14 modules, is designed to train emergency medical technicians (EMTs) in Ohio. The module contains two sections covering the following course content; cardiopulmonary resuscitation (CPR) (including artificial ventilation, foreign body obstructions, adjunctive equipment and special techniques, artificial…

  12. Betonreparationers holdbarhed (Durability of Concrete Repairs)

    DEFF Research Database (Denmark)

    Brimnes, Eydbjørn; Dali, Bogi í; Larsen, Erik Stoklund

    1999-01-01

    Concrete repairs on 11 pillars on bridges built in the sixties and repaired 8 to 9 years ago have been examined. Especially the chloride penetration in the repair concrete have been measured. Chloride penetration in the repair concrete is much lower than in the original concrete....

  13. Meniscal repair devices.

    Science.gov (United States)

    Barber, F A; Herbert, M A

    2000-09-01

    Meniscal repair devices not requiring accessory incisions are attractive. Many factors contribute to their clinical effectiveness including their biomechanical characteristics. This study compared several new meniscal repair devices with standard meniscal suture techniques. Using a porcine model, axis-of-insertion loads were applied to various meniscal sutures and repair devices. A single device or stitch was placed in a created meniscal tear and a load applied. Both loads and modes of failure were recorded. The load-to-failure data show stratification into 4 distinct statistical groups. Group A, 113 N for a double vertical stitch; group B, 80 N for a single vertical stitch; group C, 57 N for the BioStinger, 56 N for a horizontal mattress stitch, and 50 N for the T-Fix stitch; and group D, 33 N for the Meniscus Arrow (inserted by hand or gun), 32 N for the Clearfix screw, 31 N for the SDsorb staple, 30 N for the Mitek meniscal repair system, and 27 N for the Biomet staple. The failure mechanism varied. Sutures broke away from the knot. The Meniscus Arrow and BioStinger pulled through the inner rim with the crossbar intact. The Clearfix screw failed by multiple mechanisms, whereas 1 leg of the SDsorb staple always pulled out of the outer rim. The Mitek device usually failed by pullout from the inner rim. The Biomet staple always broke at the crosshead or just below it. Although the surgeon should be aware of the material properties of the repair technique chosen for a meniscal repair, this information is only an indication of device performance and may not correlate with clinical healing results.

  14. Development and Evaluation of a Continuing Education Program for Nursing Technicians at a Pediatric Cardiac Intensive Care Unit in a Developing Country.

    Science.gov (United States)

    Borim, Bruna Cury; Croti, Ulisses A; Silveira, Patricia C; De Marchi, Carlos H; Moscardini, Airton C; Hickey, Patricia; Jenkins, Kathy

    2017-11-01

    The nursing profession faces continuous transformations demonstrating the importance of professional continuing education to extend knowledge following technological development without impairing quality of care. Nursing assistants and technicians account for nearly 80% of nursing professionals in Brazil and are responsible for uninterrupted patient care. Extensive knowledge improvement is needed to achieve excellence in nursing care. The objective was to develop and evaluate a continuing education program for nursing technicians at a pediatric cardiac intensive care unit (PCICU) using a virtual learning environment entitled EDUCATE. From July to September 2015, a total of 24 nursing technicians working at the PCICU at a children's hospital located in the northwestern region of São Paulo state (Brazil) fully participated in the continuing education program developed in a virtual learning environment using Wix platform, allowing access to video classes and pre- and post-training theoretical evaluation questionnaires outside the work environment. The evaluation tools recorded participants' knowledge evolution, technological difficulties, educational, and overall rating. Knowledge development was descriptively presented as positive in more than 66.7%. Content and training were considered "excellent" by most participants and 90% showed an interest in the use of technological resources. Technical difficulties were found and quickly resolved by 40% of participants including Internet access, login, and lack of technical expertise. The continuing education program using a virtual learning environment positively contributed to the improvement in theoretical knowledge of nursing technicians in PCICU.

  15. Residual stress by repair welds

    International Nuclear Information System (INIS)

    Mochizuki, Masahito; Toyoda, Masao

    2003-01-01

    Residual stress by repair welds is computed using the thermal elastic-plastic analysis with phase-transformation effect. Coupling phenomena of temperature, microstructure, and stress-strain fields are simulated in the finite-element analysis. Weld bond of a plate butt-welded joint is gouged and then deposited by weld metal in repair process. Heat source is synchronously moved with the deposition of the finite-element as the weld deposition. Microstructure is considered by using CCT diagram and the transformation behavior in the repair weld is also simulated. The effects of initial stress, heat input, and weld length on residual stress distribution are studied from the organic results of numerical analysis. Initial residual stress before repair weld has no influence on the residual stress after repair treatment near weld metal, because the initial stress near weld metal releases due to high temperature of repair weld and then stress by repair weld regenerates. Heat input has an effect for residual stress distribution, for not its magnitude but distribution zone. Weld length should be considered reducing the magnitude of residual stress in the edge of weld bead; short bead induces high tensile residual stress. (author)

  16. Biomechanical Analysis of an Arthroscopic Broström Ankle Ligament Repair and a Suture Anchor-Augmented Repair.

    Science.gov (United States)

    Giza, Eric; Whitlow, Scott R; Williams, Brady T; Acevedo, Jorge I; Mangone, Peter G; Haytmanek, C Thomas; Curry, Eugene E; Turnbull, Travis Lee; LaPrade, Robert F; Wijdicks, Coen A; Clanton, Thomas O

    2015-07-01

    Secondary surgical repair of ankle ligaments is often indicated in cases of chronic lateral ankle instability. Recently, arthroscopic Broström techniques have been described, but biomechanical information is limited. The purpose of the present study was to analyze the biomechanical properties of an arthroscopic Broström repair and augmented repair with a proximally placed suture anchor. It was hypothesized that the arthroscopic Broström repairs would compare favorably to open techniques and that augmentation would increase the mean repair strength at time zero. Twenty (10 matched pairs) fresh-frozen foot and ankle cadaveric specimens were obtained. After sectioning of the lateral ankle ligaments, an arthroscopic Broström procedure was performed on each ankle using two 3.0-mm suture anchors with #0 braided polyethylene/polyester multifilament sutures. One specimen from each pair was augmented with a 2.9-mm suture anchor placed 3 cm proximal to the inferior tip of the lateral malleolus. Repairs were isolated and positioned in 20 degrees of inversion and 10 degrees of plantarflexion and loaded to failure using a dynamic tensile testing machine. Maximum load (N), stiffness (N/mm), and displacement at maximum load (mm) were recorded. There were no significant differences between standard arthroscopic repairs and the augmented repairs for mean maximum load and stiffness (154.4 ± 60.3 N, 9.8 ± 2.6 N/mm vs 194.2 ± 157.7 N, 10.5 ± 4.7 N/mm, P = .222, P = .685). Repair augmentation did not confer a significantly higher mean strength or stiffness at time zero. Mean strength and stiffness for the arthroscopic Broström repair compared favorably with previous similarly tested open repair and reconstruction methods, validating the clinical feasibility of an arthroscopic repair. However, augmentation with an additional proximal suture anchor did not significantly strengthen the repair. © The Author(s) 2015.

  17. Development of new core competencies for Taiwanese Emergency Medical Technicians.

    Science.gov (United States)

    Chang, Yu-Tung; Tsai, Kuang-Chau; Williams, Brett

    2018-01-01

    Core competencies are considered the foundation for establishing Emergency Medical Technician (EMT) and paramedic curricula, and for ensuring performance standards in the delivery of prehospital care. This study surveyed EMT instructors and medical directors to identify the most desirable core competencies for all levels of EMTs in Taiwan. A principal components analysis with Varimax rotation was conducted. An online questionnaire was distributed to obtain perspectives of EMT instructors and medical directors on the most desirable core competencies for EMTs. The target population was EMT training-course instructors and medical directors of fire departments in Taiwan. The questionnaire comprised 61 competency items, and multiple-choice and open-ended questions were used to obtain respondents' perspectives of the Taiwanese EMT training and education system. The results identified three factors at EMT-1 and EMT-2 levels and five factors at the EMT-Paramedic level. The factors for EMT-1 and EMT-2 were similar, and those for EMT-Paramedics identified further comprehensive competence perspectives. The key factors that appear to influence the development of the Taiwanese Emergency Medical Services (EMS) education system are the attitude of authorities, the licensure system, and legislation. The findings present new core competencies for the Taiwanese EMT system and provide capacity to redesign curricula and reconsider roles for EMT-1 and EMT-2 technicians. At the EMT-Paramedic level, the findings demonstrate the importance of incorporating competency standards in the current skills-based curriculum. Moreover, the core-competencies gap that exists between Taiwanese EMT-1s, EMT-2s, and EMT-Paramedics and internationally recognized core competencies needs to be addressed. By identifying the key factors that potentially impact the development of the EMS education system, such as the attitude of authorities, the licensure system, and legislation, these findings will inform

  18. GPA/GPSA/OSU-Okmulgee natural gas compression technician training program

    Energy Technology Data Exchange (ETDEWEB)

    Doede, S.

    1999-07-01

    Approximately one year ago, OSU-Okmulgee and the Gas Processors Association began discussions about the possibility of developing a natural Gas Technician Training Program for GPA members. Following a presentation to the Membership and Services Committee, Chairman John Ehlers solicited and obtained the approval of the GPA Executive Committee to sponsor the program. Participation in the program was also made available to GPSA members. The purpose of the program is to upgrade the technical competency and professional level of incoming natural gas compression technicians. It educates students to analytically diagnose, service and maintain gas compression equipment and systems using industry recommended procedures, special tools and service information. It also provides course content, which will enable successful graduates to advance in position after additional experience, and to understand new systems, technologies and components as they are introduced. The two-year Associate-In-Applied Science Degree program includes six successive college semesters. Nearly one-half of the time is designated for technical/academic education at Oklahoma State University-Okmulgee with the balance of time allocated for on-the-job internship experiences at sponsoring GPA/GPSA members. Each block of technical education and general education course work is followed by an immediate work experience time period designated to reinforce the technical and general education. These time periods are approximately seven and one-half weeks in length each. It is essential for the success of the students and the program that the students' education at OSU-Okmulgee and work experiences at GPA/GPSA member facilities be closely aligned for maximum student learning and retention. In addition to technical classes on gas compression equipment and components, the courses offered in math, speech, technical writing, psychology and ethics for example, prepare students to be able to communicate well, get

  19. The time course of repair of ultraviolet-induced DNA damage; implications for the structural organization of repair

    International Nuclear Information System (INIS)

    Collins, A.; Squires, S.

    1986-01-01

    Alternative molecular mechanisms can be envisaged for the cellular repair of UV-damaged DNA. In the 'random collision' model, DNA damage distributed throughout the genome is recognised and repaired by a process of random collision between DNA damage and repair enzymes. The other model assumes a 'processive' mechanism, whereby DNA is scanned for damage by a repair complex moving steadily along its length. Random collision should result in a declining rate of repair with time as the concentration of lesions in the DNA falls; but the processive model predicts a constant rate until scanning is complete. The authors have examined the time course of DNA repair in human fibroblasts given low doses of UV light. Using 3 distinct assays, the authors find no sign of a constant repair rate after 4 J/m 2 or less, even when the first few hours after irradiation are examined. Thus DNA repair is likely to depend on random collision. (Auth.)

  20. Study of the combined action of gamma radiation and static electric fields in human cells

    International Nuclear Information System (INIS)

    Moron, Michelle Mendes

    2008-01-01

    The basic principle of radiotherapy is the one of maximizing damage to the tumor, while minimizing it in neighboring health tissues. Several strategies have been worked out aiming at increasing cellular radiosensitivity, and among them is the use of exogenous fields. Our goal in this work is the study in human cells of the effect resulting from the association of irradiation with exposure to exogenous static electric fields. The T47D cell line of breast cancer cells was irradiated with gammas in the 0 - 8 Gy doses range. The corresponding survival curve provided information on the radiosensitivity of this cell line. The rate of cell deaths per Gray in the 0 - 8 Gy range exhibited a maximum at 2 Gy, which corresponds to the most efficient irradiation dose. The viability of this T47D cells exposed to both gamma radiation and 1.250 V/cm static electric field (SEF) was about 12% lower than when only irradiated. The sole exposure of the cells to SEF by 24 and 72 hours didn't induce toxicity. Immunofluorescence runs carried out in irradiated normal MRC5 cell line of human lung fibroblast, without and with exposition to a SEF, have quantified the expression of the y- H2AX histone. The amount of phosphorylated histones was approximately 40% higher after irradiation with 2 Gy plus exposure to a SEF by 1 hour, showing that the electric field negatively interfered in the repairing process of the DNA double strand breaks. The flow cytometry analysis with FACS allowed the investigation of a possible interference of radiation and SEF in the cell distributions among the cellular cycle phases. It was found that in T47D cells treated with 1 and 2 Gy by 24 hours the SEF also negatively interfered in the DNA repairing process, as evidenced by the higher accumulation of cells in the S phase. Therefore, it would be possible to conclude that static and exogenous electric fields are able of negatively interfering in the cellular repair and, presumably, in DNA repair. (author)

  1. Comparative Analysis of Ukrainian and Foreign Scholars′ Views On Interpretation of Such Terms as Competency, Professional Competency, Professional Competency of Technicians in Food Technology

    OpenAIRE

    Yakovchuk Olha

    2017-01-01

    The article deals with a comparative analysis of the content of such terms as competency, competence and professional competency of technicians in food technology. Special attention has been given to domestic and foreign scholars′ research findings on the matter in order to consider the genesis of the term “competency” and its spreading within Ukrainian and foreign pedagogy. Based on the comparison of European standards and the educational and qualification-based specification of technicians ...

  2. A biomechanical evaluation of all-inside 2-stitch meniscal repair devices with matched inside-out suture repair.

    Science.gov (United States)

    Ramappa, Arun J; Chen, Alvin; Hertz, Benjamin; Wexler, Michael; Grimaldi Bournissaint, Leandro; DeAngelis, Joseph P; Nazarian, Ara

    2014-01-01

    Many all-inside suture-based devices are currently available, including the Meniscal Cinch, FasT-Fix, Ultra FasT-Fix, RapidLoc, MaxFire, and CrossFix System. These different devices have been compared in various configurations, but to our knowledge, the Sequent meniscal repair device, which applies running sutures, has not been compared with the Ultra FasT-Fix, nor has it been compared with its suture, No. 0 Hi-Fi, using an inside-out repair technique. To assess the quality of the meniscal repair, all new devices should be compared with the gold standard: the inside-out repair. To that end, this study aims to compare the biomechanical characteristics of running sutures delivered by the Sequent meniscal repair device with 2 vertical mattress sutures applied using the Ultra FasT-Fix device and with 2 vertical mattress sutures using an inside-out repair technique with No. 0 Hi-Fi suture. Controlled laboratory study. Paired (medial and lateral), fresh-frozen porcine menisci were randomly assigned to 1 of 3 groups: Sequent (n = 17), Ultra FasT-Fix (n = 19), and No. 0 Hi-Fi inside-out repair (n = 20). Bucket-handle tears were created in all menisci and were subjected to repair according to their grouping. Once repaired, the specimens were subjected to cyclic loading (100, 300, and 500 cycles), followed by loading to failure. The Sequent and Ultra FasT-Fix device repairs and the suture repair exhibited low initial displacements. The Sequent meniscal repair device demonstrated the lowest displacement in response to cyclic loading. No. 0 Hi-Fi suture yielded the highest load to failure. With the development of the next generation of all-inside meniscal repair devices, surgeons may use these findings to select the method best suited for their patients. The Sequent meniscal repair device displays the least amount of displacement during cyclic loading but has a similar failure load to other devices.

  3. An Analysis of the Future Need for Certified Animal Health Technicians and Instructional Program Content.

    Science.gov (United States)

    Nevada State Council on Occupational Education, Carson City.

    A study examined the future need for certified animal health technicians (CAHT) in Nevada and the skills/knowledge that future CAHTs will need. Questionnaires were mailed to all of Nevada's 306 licensed veterinarians; 100 (32.68%) responded. The estimated numbers of CAHTs needed by the state's veterinarians in 1, 3, and 5 years were 62, 142, and…

  4. The journey of DNA repair.

    Science.gov (United States)

    Saini, Natalie

    2015-12-01

    21 years ago, the DNA Repair Enzyme was declared "Molecule of the Year". Today, we are celebrating another "year of repair", with the 2015 Nobel Prize in Chemistry being awarded to Aziz Sancar, Tomas Lindahl and Paul Modrich for their collective work on the different DNA repair pathways.

  5. Department of Defense In-House RDT&E Activities. Management Analysis Report

    Science.gov (United States)

    1987-10-30

    AIRCRAFT BY NAVY PERSONNEL; ESTABLISH HUMAN TOLERANCE LIMITS FOR THESE FORCES, DEVELOP PREVENTIVE AND THERAPEUTIC METHODS TO PROTECT PERSONNEL FROM...Engineering 436 Plant Protection and 830 Mechanical Engineering Quarantine 840 Nuclear Engineering 437 Horticulture S50 Electrical Engineering 440...Technician 648 Therapeutic Radiological 1311 Physical Science Technologist Technician 649 Medical Machine Technician 1316 Hydraulic Technician 650 Medical

  6. Thymus repair compared with hemopoiesis repair in spleen after protracted irradiation

    International Nuclear Information System (INIS)

    Mackova, N.

    1987-01-01

    Matured female mice of ICR strain were irradiated from a 60 Co source with a daily dose rate of 5 Gy till total accumulated dose of 10 Gy for 2 days. Animals were examined in various intervals within 42 days after irradiation. The results revealed that protracted irradiation will induce a massive injury to hemopoiesis. The first repair processes occurred in thymus and were characterized by two phases. The first repair wave peaked about the day 10 and the second about the day 30 after irradiation. The repair processes observed in the red pulp of the spleen reached their highest intensity approximately between the days 14-16 after irradiation. (author)

  7. The Iowa new practice model: Advancing technician roles to increase pharmacists' time to provide patient care services.

    Science.gov (United States)

    Andreski, Michael; Myers, Megan; Gainer, Kate; Pudlo, Anthony

    Determine the effects of an 18-month pilot project using tech-check-tech in 7 community pharmacies on 1) rate of dispensing errors not identified during refill prescription final product verification; 2) pharmacist workday task composition; and 3) amount of patient care services provided and the reimbursement status of those services. Pretest-posttest quasi-experimental study where baseline and study periods were compared. Pharmacists and pharmacy technicians in 7 community pharmacies in Iowa. The outcome measures were 1) percentage of technician verified refill prescriptions where dispensing errors were not identified on final product verification; 2) percentage of time spent by pharmacists in dispensing, management, patient care, practice development, and other activities; 3) the number of pharmacist patient care services provided per pharmacist hours worked; and 4) percentage of time that technician product verification was used. There was no significant difference in overall errors (0.2729% vs. 0.5124%, P = 0.513), patient safety errors (0.0525% vs. 0.0651%, P = 0.837), or administrative errors (0.2204% vs. 0.4784%, P = 0.411). Pharmacist's time in dispensing significantly decreased (67.3% vs. 49.06%, P = 0.005), and time in direct patient care (19.96% vs. 34.72%, P = 0.003), increased significantly. Time in other activities did not significantly change. Reimbursable services per pharmacist hour (0.11 vs. 0.30, P = 0.129), did not significantly change. Non-reimbursable services increased significantly (2.77 vs. 4.80, P = 0.042). Total services significantly increased (2.88 vs. 5.16, P = 0.044). Pharmacy technician product verification of refill prescriptions preserved dispensing safety while significantly increasing the time spent in delivery of pharmacist provided patient care services. The total number of pharmacist services provided per hour also increased significantly, driven primarily by a significant increase in the number of non

  8. Laparoscopic totally extraperitoneal inguinal hernia repair: lessons learned from 3,100 hernia repairs over 15 years.

    Science.gov (United States)

    Dulucq, Jean-Louis; Wintringer, Pascal; Mahajna, Ahmad

    2009-03-01

    Two revolutions in inguinal hernia repair surgery have occurred during the last two decades. The first was the introduction of tension-free hernia repair by Liechtenstein in 1989 and the second was the application of laparoscopic surgery to the treatment of inguinal hernia in the early 1990s. The purposes of this study were to assess the safety and effectiveness of laparoscopic totally extraperitoneal (TEP) repair and to discuss the technical changes that we faced on the basis of our accumulative experience. Patients who underwent an elective inguinal hernia repair at the Department of Abdominal Surgery at the Institute of Laparoscopic Surgery (ILS), Bordeaux, between June 1990 and May 2005 were enrolled retrospectively in this study. Patient demographic data, operative and postoperative course, and outpatient follow-up were studied. A total of 3,100 hernia repairs were included in the study. The majority of the hernias were repaired by TEP technique; the repair was done by transabdominal preperitoneal (TAPP) repair in only 3%. Eleven percent of the hernias were recurrences after conventional repair. Mean operative time was 17 min in unilateral hernia and 24 min in bilateral hernia. There were 36 hernias (1.2%) that required conversion: 12 hernias were converted to open anterior Liechtenstein and 24 to laparoscopic TAPP technique. The incidence of intraoperative complications was low. Most of the patients were discharged at the second day of the surgery. The overall postoperative morbidity rate was 2.2%. The incidence of recurrence rate was 0.35%. The recurrence rate for the first 200 repairs was 2.5%, but it decreased to 0.47% for the subsequent 1,254 hernia repairs According to our experience, in the hands of experienced laparoscopic surgeons, laparoscopic hernia repair seems to be the favored approach for most types of inguinal hernias. TEP is preferred over TAPP as the peritoneum is not violated and there are fewer intra-abdominal complications.

  9. Performance experiments with alternative advanced teleoperator control modes for a simulated solar maximum satellite repair

    Science.gov (United States)

    Das, H.; Zak, H.; Kim, W. S.; Bejczy, A. K.; Schenker, P. S.

    1992-01-01

    Experiments are described which were conducted at the JPL Advanced Teleoperator Lab to demonstrate and evaluate the effectiveness of various teleoperator control modes in the performance of a simulated Solar Max Satellite Repair (SMSR) task. THe SMSR was selected as a test because it is very rich in performance capability requirements and it actually has been performed by two EVA astronauts in the Space Shuttle Bay in 1984. The main subtasks are: thermal blanket removal; installation of a hinge attachment for electrical panel opening; opening of electrical panel; removal of electrical connectors; relining of cable bundles; replacement of electrical panel; securing parts and cables; re-mate electrical connectors; closing of electrical panel; and reinstating thermal blanket. The current performance experiments are limited to thermal blanket cutting, electrical panel unbolting and handling electrical bundles and connectors. In one formal experiment even different control modes were applied to the unbolting and reinsertion of electrical panel screws subtasks. The seven control modes are alternative combinations of manual position and rate control with force feedback and remote compliance referenced to force-torque sensor information. Force-torque sensor and end effector position data and task completion times were recorded for analysis and quantification of operator performance.

  10. 40 CFR 63.1024 - Leak repair.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Leak repair. 63.1024 Section 63.1024... Standards for Equipment Leaks-Control Level 2 Standards § 63.1024 Leak repair. (a) Leak repair schedule. The owner or operator shall repair each leak detected as soon as practical, but not later than 15 calendar...

  11. Evaluation of Repair Tension in Arthroscopic Rotator Cuff Repair: Does It Really Matter to the Integrity of the Rotator Cuff?

    Science.gov (United States)

    Kim, Do Hoon; Jang, Young Hoon; Choi, Young Eun; Lee, Hwa-Ryeong; Kim, Sae Hoon

    2016-11-01

    Repair tension of a torn rotator cuff can affect healing after repair. However, a measurement of the actual tension during arthroscopic rotator cuff repair is not feasible. The relationship between repair tension and healing of a rotator cuff repair remains unclear. The purpose of this study was to evaluate the effect of repair tension on healing at the repair site. The hypothesis was that repair tension would be a major factor in determining the anatomic outcome of rotator cuff repair. Cohort study; Level of evidence, 2. Arthroscopic rotator cuff repairs (132 patients) for full-thickness rotator cuff tears were analyzed. An intraoperative model was designed for the estimation of repair tension using a tensiometer. Magnetic resonance imaging (MRI) was performed approximately 1 year (mean [±SD], 12.7 ± 3.2 months) postoperatively for the evaluation of healing at the repair site. Multivariable analysis was performed for tear size, amount of retraction, and fatty degeneration (FD) of rotator cuff muscles. The mean repair tension measured during the arthroscopic procedure was 28.5 ± 23.1 N. There was a statistically significant correlation between tension and tear size (Pearson correlation coefficient [PCC], 0.529; P repair tension also showed a significant inverse correlation with healing at the repair site (SCC, 0.195; P = .025). However, when sex, age, tear size, amount of retraction, tendon quality, and FD of rotator cuff muscles were included for multivariable logistic regression analysis, only FD of the infraspinatus showed an association with the anatomic outcome of repair (Exp(B) = 0.596; P = .010). Our intraoperative model for the estimation of rotator cuff repair tension showed an inverse correlation of repair tension with healing at the repair site, suggesting that complete healing is less likely with high-tension repairs. A significant association was observed on MRI between a high level of FD of the infraspinatus and repaired tendon integrity. © 2016

  12. Availability of the electrical supply system of emergency sources of 900-MW pressurized water nuclear power plants

    International Nuclear Information System (INIS)

    Blin, A.

    A study made by CEA and EDF on the time-dependent probability of simultaneous loss of the electrical supply system from emergency sources is reported. Aspects covered include the availability of the electrical supply system in all possible conditions (2 available external sources, 1 available external source...) and the probability for repair after total loss of supply sources

  13. 40 CFR 63.1005 - Leak repair.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Leak repair. 63.1005 Section 63.1005... Standards for Equipment Leaks-Control Level 1 § 63.1005 Leak repair. (a) Leak repair schedule. The owner or operator shall repair each leak detected no later than 15 calendar days after it is detected, except as...

  14. 40 CFR 65.105 - Leak repair.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 15 2010-07-01 2010-07-01 false Leak repair. 65.105 Section 65.105... FEDERAL AIR RULE Equipment Leaks § 65.105 Leak repair. (a) Leak repair schedule. The owner or operator shall repair each leak detected as soon as practical but not later than 15 calendar days after it is...

  15. Effect of repair resin type and surface treatment on the repair strength of polyamide denture base resin.

    Science.gov (United States)

    Gundogdu, Mustafa; Yanikoglu, Nuran; Bayindir, Funda; Ciftci, Hilal

    2015-01-01

    The purpose of the present study was to evaluate the effects of different repair resins and surface treatments on the repair strength of a polyamide denture base material. Polyamide resin specimens were prepared and divided into nine groups according to the surface treatments and repair materials. The flexural strengths were measured with a 3-point bending test. Data were analyzed with a 2-way analysis of variance, and the post-hoc Tukey test (α=0.05). The effects of the surface treatments on the surface of the polyamide resin were examined using scanning electron microscopy. The repair resins and surface treatments significantly affected the repair strength of the polyamide denture base material (p0.05). The flexural strength of the specimens repaired with the polyamide resin was significantly higher than that of those repaired with the heat-polymerized and autopolymerizing acrylic resins.

  16. The impact of endovascular repair on specialties performing abdominal aortic aneurysm repair

    NARCIS (Netherlands)

    Ultee, Klaas H J; Hurks, Rob; Buck, Dominique B.; Dasilva, George S.; Soden, Peter A.; Van Herwaarden, Joost A.; Verhagen, Hence J M; Schermerhorn, Marc L.

    2015-01-01

    Background Abdominal aortic aneurysm (AAA) repair has been performed by various surgical specialties for many years. Endovascular aneurysm repair (EVAR) may be a disruptive technology, having an impact on which specialties care for patients with AAA. Therefore, we examined the proportion of AAA

  17. The impact of endovascular repair on specialties performing abdominal aortic aneurysm repair

    NARCIS (Netherlands)

    K.H.J. Ultee (Klaas); R. Hurks (Rob); D.B. Buck (Dominique B.); G.S. Dasilva (George S.); P.A. Soden (Peter A.); J.A. van Herwaarden (Joost); H.J.M. Verhagen (Hence); M.L. Schermerhorn (Marc)

    2015-01-01

    textabstractBackground Abdominal aortic aneurysm (AAA) repair has been performed by various surgical specialties for many years. Endovascular aneurysm repair (EVAR) may be a disruptive technology, having an impact on which specialties care for patients with AAA. Therefore, we examined the proportion

  18. Single cell wound generates electric current circuit and cell membrane potential variations that requires calcium influx.

    Science.gov (United States)

    Luxardi, Guillaume; Reid, Brian; Maillard, Pauline; Zhao, Min

    2014-07-24

    Breaching of the cell membrane is one of the earliest and most common causes of cell injury, tissue damage, and disease. If the compromise in cell membrane is not repaired quickly, irreversible cell damage, cell death and defective organ functions will result. It is therefore fundamentally important to efficiently repair damage to the cell membrane. While the molecular aspects of single cell wound healing are starting to be deciphered, its bio-physical counterpart has been poorly investigated. Using Xenopus laevis oocytes as a model for single cell wound healing, we describe the temporal and spatial dynamics of the wound electric current circuitry and the temporal dynamics of cell membrane potential variation. In addition, we show the role of calcium influx in controlling electric current circuitry and cell membrane potential variations. (i) Upon wounding a single cell: an inward electric current appears at the wound center while an outward electric current is observed at its sides, illustrating the wound electric current circuitry; the cell membrane is depolarized; calcium flows into the cell. (ii) During cell membrane re-sealing: the wound center current density is maintained for a few minutes before decreasing; the cell membrane gradually re-polarizes; calcium flow into the cell drops. (iii) In conclusion, calcium influx is required for the formation and maintenance of the wound electric current circuitry, for cell membrane re-polarization and for wound healing.

  19. Treatment and Controversies in Paraesophageal Hernia Repair

    Directory of Open Access Journals (Sweden)

    P. Marco eFisichella

    2015-04-01

    Full Text Available Background: Historically all paraesophageal hernias were repaired surgically, today intervention is reserved for symptomatic paraesophageal hernias. In this review, we describe the indications for repair and explore the controversies in paraesophageal hernia repair, which include a comparison of open to laparoscopic paraesophageal hernia repair, the necessity of complete sac excision, the routine performance of fundoplication, and the use of mesh for hernia repair.Methods: We searched Pubmed for papers published between 1980 and 2015 using the following keywords: hiatal hernias, paraesophageal hernias, regurgitation, dysphagia, gastroesophageal reflux disease, aspiration, GERD, endoscopy, manometry, pH monitoring, proton pump inhibitors, anemia, iron deficiency anemia, Nissen fundoplication, sac excision, mesh, mesh repair. Results: Indications for paraesophageal hernia repair have changed, and currently symptomatic paraesophageal hernias are recommended for repair. In addition, it is important not to overlook iron-deficiency anemia and pulmonary complaints, which tend to improve with repair. Current practice favors a laparoscopic approach, complete sac excision, primary crural repair with or without use of mesh, and a routine fundoplication.

  20. Double-Strand DNA Break Repair in Mycobacteria.

    Science.gov (United States)

    Glickman, Michael S

    2014-10-01

    Discontinuity of both strands of the chromosome is a lethal event in all living organisms because it compromises chromosome replication. As such, a diversity of DNA repair systems has evolved to repair double-strand DNA breaks (DSBs). In part, this diversity of DSB repair systems has evolved to repair breaks that arise in diverse physiologic circumstances or sequence contexts, including cellular states of nonreplication or breaks that arise between repeats. Mycobacteria elaborate a set of three genetically distinct DNA repair pathways: homologous recombination, nonhomologous end joining, and single-strand annealing. As such, mycobacterial DSB repair diverges substantially from the standard model of prokaryotic DSB repair and represents an attractive new model system. In addition, the presence in mycobacteria of a DSB repair system that can repair DSBs in nonreplicating cells (nonhomologous end joining) or when DSBs arise between repeats (single-strand annealing) has clear potential relevance to Mycobacterium tuberculosis pathogenesis, although the exact role of these systems in M. tuberculosis pathogenesis is still being elucidated. In this article we will review the genetics of mycobacterial DSB repair systems, focusing on recent insights.

  1. Ultrasound determination of rotator cuff tear repairability

    Science.gov (United States)

    Tse, Andrew K; Lam, Patrick H; Walton, Judie R; Hackett, Lisa

    2015-01-01

    Background Rotator cuff repair aims to reattach the torn tendon to the greater tuberosity footprint with suture anchors. The present study aimed to assess the diagnostic accuracy of ultrasound in predicting rotator cuff tear repairability and to assess which sonographic and pre-operative features are strongest in predicting repairability. Methods The study was a retrospective analysis of measurements made prospectively in a cohort of 373 patients who had ultrasounds of their shoulder and underwent rotator cuff repair. Measurements of rotator cuff tear size and muscle atrophy were made pre-operatively by ultrasound to enable prediction of rotator cuff repairability. Tears were classified following ultrasound as repairable or irreparable, and were correlated with intra-operative repairability. Results Ultrasound assessment of rotator cuff tear repairability has a sensitivity of 86% (p tear size (p tear size ≥4 cm2 or anteroposterior tear length ≥25 mm indicated an irreparable rotator cuff tear. Conclusions Ultrasound assessment is accurate in predicting rotator cuff tear repairability. Tear size or anteroposterior tear length and age were the best predictors of repairability. PMID:27582996

  2. Handbook of adhesive bonded structural repair

    CERN Document Server

    Wegman, Raymond F

    1992-01-01

    Provides repair methods for adhesive bonded and composite structures; identifies suitable materials and equipment for repairs; describes damage evaluation criteria and techniques, and methods of inspection before and after repair.

  3. Scarf Repair of Composite Laminates

    Directory of Open Access Journals (Sweden)

    Xie Zonghong

    2016-01-01

    Full Text Available The use of composite materials, such as carbon-fiber reinforced plastic (CFRP composites, aero-structures has led to an increased need of advanced assembly joining and repair technologies. Adhesive bonded repairs as an alternative to recover full or part of initial strength were investigated. Tests were conducted with the objective of evaluating the effectiveness of techniques used for repairing damage fiber reinforced laminated composites. Failure loads and failure modes were generated and compared with the following parameters: scarf angles, roughness of grind tool and number of external plies. Results showed that scarf angle was the critical parameter and the largest tensile strength was observed with the smallest scarf angle. Besides, the use of external plies at the outer surface could not increase the repairs efficiency for large scarf angle. Preparing the repair surfaces by sanding them with a sander ranging from 60 to 100 grit number had significant effect on the failure load. These results allowed the proposal of design principles for repairing CFRP structures.

  4. Overlapping sphincteroplasty and posterior repair.

    Science.gov (United States)

    Crane, Andrea K; Myers, Erinn M; Lippmann, Quinn K; Matthews, Catherine A

    2014-12-01

    Knowledge of how to anatomically reconstruct extensive posterior-compartment defects is variable among gynecologists. The objective of this video is to demonstrate an effective technique of overlapping sphincteroplasty and posterior repair. In this video, a scripted storyboard was constructed that outlines the key surgical steps of a comprehensive posterior compartment repair: (1) surgical incision that permits access to posterior compartment and perineal body, (2) dissection of the rectovaginal space up to the level of the cervix, (3) plication of the rectovaginal muscularis, (4) repair of internal and external anal sphincters, and (5) reconstruction of the perineal body. Using a combination of graphic illustrations and live video footage, tips on repair are highlighted. The goals at the end of repair are to: (1) have improved vaginal caliber, (2) increase rectal tone along the entire posterior vaginal wall, (3) have the posterior vaginal wall at a perpendicular plane to the perineal body, (4) reform the hymenal ring, and (5) not have an overly elongated perineal body. This video provides a step-by-step guide on how to perform an overlapping sphincteroplasty and posterior repair.

  5. Both base excision repair and nucleotide excision repair in humans are influenced by nutritional factors.

    Science.gov (United States)

    Brevik, Asgeir; Karlsen, Anette; Azqueta, Amaya; Tirado, Anna Estaban; Blomhoff, Rune; Collins, Andrew

    2011-01-01

    Lack of reliable assays for DNA repair has largely prevented measurements of DNA repair from being included in human biomonitoring studies. Using newly developed modifications of the comet assay we tested whether a fruit- and antioxidant-rich plant-based intervention could affect base excision repair (BER) and nucleotide excision repair (NER) in a group of 102 male volunteers. BER and NER repair capacities were measured in lymphocytes before and after a dietary intervention lasting 8 weeks. The study had one control group, one group consuming three kiwifruits per day and one group consuming a variety of antioxidant-rich fruits and plant products in addition to their normal diet. DNA strand breaks were reduced following consumption of both kiwifruits (13%, p = 0.05) and antioxidant-rich plant products (20%, p = 0.02). Increased BER (55%, p = 0.01) and reduced NER (-39%, p plant products. Reduced NER was also observed in the kiwifruit group (-38%, p = 0.05), but BER was not affected in this group. Here we have demonstrated that DNA repair is affected by diet and that modified versions of the comet assay can be used to assess activity of different DNA repair pathways in human biomonitoring studies. Copyright © 2010 John Wiley & Sons, Ltd.

  6. Magnetic Resonance Imaging of Cartilage Repair

    Science.gov (United States)

    Trattnig, Siegfried; Winalski, Carl S.; Marlovits, Stephan; Jurvelin, Jukka S.; Welsch, Goetz H.; Potter, Hollis G.

    2011-01-01

    Articular cartilage lesions are a common pathology of the knee joint, and many patients may benefit from cartilage repair surgeries that offer the chance to avoid the development of osteoarthritis or delay its progression. Cartilage repair surgery, no matter the technique, requires a noninvasive, standardized, and high-quality longitudinal method to assess the structure of the repair tissue. This goal is best fulfilled by magnetic resonance imaging (MRI). The present article provides an overview of the current state of the art of MRI of cartilage repair. In the first 2 sections, preclinical and clinical MRI of cartilage repair tissue are described with a focus on morphological depiction of cartilage and the use of functional (biochemical) MR methodologies for the visualization of the ultrastructure of cartilage repair. In the third section, a short overview is provided on the regulatory issues of the United States Food and Drug Administration (FDA) and the European Medicines Agency (EMEA) regarding MR follow-up studies of patients after cartilage repair surgeries. PMID:26069565

  7. My journey to DNA repair.

    Science.gov (United States)

    Lindahl, Tomas

    2013-02-01

    I completed my medical studies at the Karolinska Institute in Stockholm but have always been devoted to basic research. My longstanding interest is to understand fundamental DNA repair mechanisms in the fields of cancer therapy, inherited human genetic disorders and ancient DNA. I initially measured DNA decay, including rates of base loss and cytosine deamination. I have discovered several important DNA repair proteins and determined their mechanisms of action. The discovery of uracil-DNA glycosylase defined a new category of repair enzymes with each specialized for different types of DNA damage. The base excision repair pathway was first reconstituted with human proteins in my group. Cell-free analysis for mammalian nucleotide excision repair of DNA was also developed in my laboratory. I found multiple distinct DNA ligases in mammalian cells, and led the first genetic and biochemical work on DNA ligases I, III and IV. I discovered the mammalian exonucleases DNase III (TREX1) and IV (FEN1). Interestingly, expression of TREX1 was altered in some human autoimmune diseases. I also showed that the mutagenic DNA adduct O(6)-methylguanine (O(6)mG) is repaired without removing the guanine from DNA, identifying a surprising mechanism by which the methyl group is transferred to a residue in the repair protein itself. A further novel process of DNA repair discovered by my research group is the action of AlkB as an iron-dependent enzyme carrying out oxidative demethylation. Copyright © 2013. Production and hosting by Elsevier Ltd.

  8. The Weekend Effect in AAA Repair.

    Science.gov (United States)

    O'Donnell, Thomas F X; Li, Chun; Swerdlow, Nicholas J; Liang, Patric; Pothof, Alexander B; Patel, Virendra I; Giles, Kristina A; Malas, Mahmoud B; Schermerhorn, Marc L

    2018-04-18

    Conflicting reports exist regarding whether patients undergoing surgery on the weekend or later in the week experience worse outcomes. We identified patients undergoing abdominal aortic aneurysm (AAA) repair in the Vascular Quality Initiative between 2009 and 2017 [n = 38,498; 30,537 endovascular aneurysm repair (EVAR) and 7961 open repair]. We utilized mixed effects logistic regression to compare adjusted rates of perioperative mortality based on the day of repair. Tuesday was the most common day for elective repair (22%), Friday for symptomatic repairs (20%), and ruptured aneurysms were evenly distributed. Patients with ruptured aneurysms experienced similar adjusted mortality whether they underwent repair during the week or on weekends. Transfers of ruptured AAA were more common over the weekend. However, patients transferred on the weekend experienced higher adjusted mortality than those transferred during the week (28% vs 21%, P = 0.02), despite the fact that during the week, transferred patients actually experienced lower adjusted mortality than patients treated at the index hospital (21% vs 31%, P AAA repair. However, patients with ruptured AAA transferred on the weekend experienced higher mortality than those transferred during the week, suggesting a need for improvement in weekend transfer processes.

  9. THE DIFFERENTS FACES OF TRUST IN THE TOBACCO PRODUCTION IN RIO GRANDE DO SUL, BRAZIL: RELATIONS BETWEEN FARMERS AND THE FIELD TECHNICIANS

    Directory of Open Access Journals (Sweden)

    Carlise Schneider Rudnicki

    2014-02-01

    Full Text Available In region of Vale do Rio Pardo, situated in Rio Grande do Sul, Brazil, the production of tobacco is an important source of income, especially for family farmers. The discussion around tobacco production in the academic researches and society’s debate involves: the problems that smoking causes in human health and the same time, the role of farmers have been developed in the productive chain. In view of this, the aim of this article was to understand the trust relation between farms and the field technicians in the Vale do Rio Pardo region and the south side area of the Rio Grande do Sul, Brazil. 142 interviews have been accomplished with families that are producing tobacco, using a semi-structured form (qualitative and quantitative questions. The Likert scale, field diaries and observations were used as search tools. When farmers have been questioned about trust in agricultural technicians (using Likert scale, the answers were similar in the three cities: the southern Rio Grande do Sul, in Dom Feliciano, confidence is 69.7%; in the Vale do Rio Pardo, Rio Pardo and Santa Cruz do Sul, respectively, confidence is 63.3% and 64.6%, according to levels between “agree” and “disagree totally”. Besides, in this context, there is direct relation between trust in the field technicians and integration of tobacco. The informal relation between farms and the field technicians has been changed by formal contracts. Nevertheless, informality was relevant, specifically because it may help to understand how the trust emerges in friendships and family relations.

  10. Emergency Victim Care. A Training Manual for Emergency Medical Technicians. Module 3--Anatomy and Physiology. Revised.

    Science.gov (United States)

    Ohio State Dept. of Education, Columbus. Div. of Vocational Education.

    This student manual, the third in a set of 14 modules, is designed to train emergency medical technicians (EMTs) in Ohio. The module contains one section covering the following topics: general anatomical terms, the body cavities and contents, the integumentary system, the skeletal system, the muscular system, the nervous system, the respiratory…

  11. Systems Maintenance Automated Repair Tasks (SMART)

    Science.gov (United States)

    Schuh, Joseph; Mitchell, Brent; Locklear, Louis; Belson, Martin A.; Al-Shihabi, Mary Jo Y.; King, Nadean; Norena, Elkin; Hardin, Derek

    2010-01-01

    SMART is a uniform automated discrepancy analysis and repair-authoring platform that improves technical accuracy and timely delivery of repair procedures for a given discrepancy (see figure a). SMART will minimize data errors, create uniform repair processes, and enhance the existing knowledge base of engineering repair processes. This innovation is the first tool developed that links the hardware specification requirements with the actual repair methods, sequences, and required equipment. SMART is flexibly designed to be useable by multiple engineering groups requiring decision analysis, and by any work authorization and disposition platform (see figure b). The organizational logic creates the link between specification requirements of the hardware, and specific procedures required to repair discrepancies. The first segment in the SMART process uses a decision analysis tree to define all the permutations between component/ subcomponent/discrepancy/repair on the hardware. The second segment uses a repair matrix to define what the steps and sequences are for any repair defined in the decision tree. This segment also allows for the selection of specific steps from multivariable steps. SMART will also be able to interface with outside databases and to store information from them to be inserted into the repair-procedure document. Some of the steps will be identified as optional, and would only be used based on the location and the current configuration of the hardware. The output from this analysis would be sent to a work authoring system in the form of a predefined sequence of steps containing required actions, tools, parts, materials, certifications, and specific requirements controlling quality, functional requirements, and limitations.

  12. Laparoscopic repair of large suprapubic hernias.

    Science.gov (United States)

    Sikar, Hasan Ediz; Çetin, Kenan; Eyvaz, Kemal; Kaptanoglu, Levent; Küçük, Hasan Fehmi

    2017-09-01

    Suprapubic hernia is the term to describe ventral hernias located less than 4 cm above the pubic arch in the midline. Hernias with an upper margin above the arcuate line encounter technical difficulties, and the differences in repair methods forced us to define them as large suprapubic hernias. To present our experience with laparoscopic repair of large suprapubic hernias that allows adequate mesh overlap. Nineteen patients with suprapubic incisional hernias who underwent laparoscopic repair between May 2013 and January 2015 were included in the study. Patients with laparoscopic extraperitoneal repair who had a suprapubic hernia with an upper margin below the arcuate line were excluded. Two men and 17 women, with a mean age of 58.2, underwent laparoscopic repair. Most of the incisions were midline vertical (13/68.4%). Twelve (63.1%) of the patients had previous incisional hernia repair (PIHR group); the mean number of previous incisional hernia repair was 1.4. Mean defect size of the PIHR group was higher than in patients without previous repair - 107.3 cm 2 vs. 50.9 cm 2 (p < 0.05). Mean operating time of the PIHR group was higher than in patients without repair - 126 min vs. 77.9 min (p < 0.05). Although all complications occurred in the PIHR group, there was no statistically significant difference. Laparoscopic repair of large suprapubic hernias can be considered as the first option in treatment. The low recurrence rates reported in the literature and the lack of recurrence, as observed in our study, support this view.

  13. DNA repair in neurons: So if they don't divide what's to repair?

    Energy Technology Data Exchange (ETDEWEB)

    Fishel, Melissa L. [Department of Pediatrics (Section of Hematology/Oncology), Herman B Wells Center for Pediatric Research, Indiana University School of Medicine, 1044 W. Walnut, Room 302C, Indianapolis, IN 46202 (United States); Vasko, Michael R. [Department of Pharmacology and Toxicology, Indiana University School of Medicine, 1044 W. Walnut St., Indianapolis, IN 46202 (United States); Kelley, Mark R. [Department of Pediatrics (Section of Hematology/Oncology), Herman B Wells Center for Pediatric Research, Indiana University School of Medicine, 1044 W. Walnut, Room 302C, Indianapolis, IN 46202 (United States) and Department of Pharmacology and Toxicology, Indiana University School of Medicine, 1044 W. Walnut St., Indianapolis, IN 46202 (United States) and Department of Biochemistry and Molecular Biology, Indiana University School of Medicine, 1044 W. Walnut, Room 302C, Indianapolis, IN 46202 (United States)]. E-mail: mkelley@iupui.edu

    2007-01-03

    Neuronal DNA repair remains one of the most exciting areas for investigation, particularly as a means to compare the DNA repair response in mitotic (cancer) vs. post-mitotic (neuronal) cells. In addition, the role of DNA repair in neuronal cell survival and response to aging and environmental insults is of particular interest. DNA damage caused by reactive oxygen species (ROS) such as generated by mitochondrial respiration includes altered bases, abasic sites, and single- and double-strand breaks which can be prevented by the DNA base excision repair (BER) pathway. Oxidative stress accumulates in the DNA of the human brain over time especially in the mitochondrial DNA (mtDNA) and is proposed to play a critical role in aging and in the pathogenesis of several neurological disorders including Parkinson's disease, ALS, and Alzheimer's diseases. Because DNA damage accumulates in the mtDNA more than nuclear DNA, there is increased interest in DNA repair pathways and the consequence of DNA damage in the mitochondria of neurons. The type of damage that is most likely to occur in neuronal cells is oxidative DNA damage which is primarily removed by the BER pathway. Following the notion that the bulk of neuronal DNA damage is acquired by oxidative DNA damage and ROS, the BER pathway is a likely area of focus for neuronal studies of DNA repair. BER variations in brain aging and pathology in various brain regions and tissues are presented. Therefore, the BER pathway is discussed in greater detail in this review than other repair pathways. Other repair pathways including direct reversal, nucleotide excision repair (NER), mismatch repair (MMR), homologous recombination and non-homologous end joining are also discussed. Finally, there is a growing interest in the role that DNA repair pathways play in the clinical arena as they relate to the neurotoxicity and neuropathy associated with cancer treatments. Among the numerous side effects of cancer treatments, major

  14. Procedures for maintenance and repairs

    International Nuclear Information System (INIS)

    Pickel, E.

    1981-01-01

    After a general review of the operation experience in the history of more than 12 operating years, the organization in the plant will be shown with special aspect to quality assurance, capacity of the workshops and connected groups as radiation protection, chemical laboratories etc. The number, time intervals and manpower effort for the repeating tests will be discussed. Reasons and examples for back-fitting activities in the plant are given. Besides special repair and maintenance procedures as repair of the steam generators, in-service inspection of the reactor pressure vessel, repair of a feed-water pipe and repair of the core structure in the pressure vessel, the general system to handle maintenance and repair-work in the KWO-plant will be shown. This includes also the detailed planning of the annual refueling and revision of the plant. (orig./RW)

  15. DNA repair genes

    International Nuclear Information System (INIS)

    Morimyo, Mitsuoki

    1995-01-01

    Fission yeast S. pombe is assumed to be a good model for cloning of human DNA repair genes, because human gene is normally expressed in S. pombe and has a very similar protein sequence to yeast protein. We have tried to elucidate the DNA repair mechanisms of S. pombe as a model system for those of mammals. (J.P.N.)

  16. An Assessment of the State of the Art of Curriculum Materials and a Status Assessment of Training Programs for Robotics/Automated Systems Technicians. Task Analysis and Descriptions of Required Job Competencies of Robotics/Automated Systems Technicians.

    Science.gov (United States)

    Hull, Daniel M.; Lovett, James E.

    This report presents the results of research conducted to determine the current state of the art of robotics/automated systems technician (RAST) training offered in the United States. Section I discusses the RAST curriculum project, of which this state-of-the-art review is a part, and offers a RAST job description. Section II describes the…

  17. Repair of steam turbines by welding

    International Nuclear Information System (INIS)

    Bohnstedt, H.J.; Loebert, P.

    1987-01-01

    In some cases, turbine parts can be repaired by welding, even rotating parts such as the shaft or the blades. Practical examples of successful repair work are explained, as for instance: welding of the last web of the turbine wheel of two MD-rotors, repair of erosion damage on turbine blades, of solid-matter erosion on a medium-pressure blading, or welding repair of a high-pressure turbine casing. (DG) [de

  18. Current Biomechanical Concepts for Rotator Cuff Repair

    Science.gov (United States)

    2013-01-01

    For the past few decades, the repair of rotator cuff tears has evolved significantly with advances in arthroscopy techniques, suture anchors and instrumentation. From the biomechanical perspective, the focus in arthroscopic repair has been on increasing fixation strength and restoration of the footprint contact characteristics to provide early rehabilitation and improve healing. To accomplish these objectives, various repair strategies and construct configurations have been developed for rotator cuff repair with the understanding that many factors contribute to the structural integrity of the repaired construct. These include repaired rotator cuff tendon-footprint motion, increased tendon-footprint contact area and pressure, and tissue quality of tendon and bone. In addition, the healing response may be compromised by intrinsic factors such as decreased vascularity, hypoxia, and fibrocartilaginous changes or aforementioned extrinsic compression factors. Furthermore, it is well documented that torn rotator cuff muscles have a tendency to atrophy and become subject to fatty infiltration which may affect the longevity of the repair. Despite all the aforementioned factors, initial fixation strength is an essential consideration in optimizing rotator cuff repair. Therefore, numerous biomechanical studies have focused on elucidating the strongest devices, knots, and repair configurations to improve contact characteristics for rotator cuff repair. In this review, the biomechanical concepts behind current rotator cuff repair techniques will be reviewed and discussed. PMID:23730471

  19. Tacit Knowledge Capture and the Brain-Drain at Electrical Utilities

    Science.gov (United States)

    Perjanik, Nicholas Steven

    As a consequence of an aging workforce, electric utilities are at risk of losing their most experienced and knowledgeable electrical engineers. In this research, the problem was a lack of understanding of what electric utilities were doing to capture the tacit knowledge or know-how of these engineers. The purpose of this qualitative research study was to explore the tacit knowledge capture strategies currently used in the industry by conducting a case study of 7 U.S. electrical utilities that have demonstrated an industry commitment to improving operational standards. The research question addressed the implemented strategies to capture the tacit knowledge of retiring electrical engineers and technical personnel. The research methodology involved a qualitative embedded case study. The theories used in this study included knowledge creation theory, resource-based theory, and organizational learning theory. Data were collected through one time interviews of a senior electrical engineer or technician within each utility and a workforce planning or training professional within 2 of the 7 utilities. The analysis included the use of triangulation and content analysis strategies. Ten tacit knowledge capture strategies were identified: (a) formal and informal on-boarding mentorship and apprenticeship programs, (b) formal and informal off-boarding mentorship programs, (c) formal and informal training programs, (d) using lessons learned during training sessions, (e) communities of practice, (f) technology enabled tools, (g) storytelling, (h) exit interviews, (i) rehiring of retirees as consultants, and (j) knowledge risk assessments. This research contributes to social change by offering strategies to capture the know-how needed to ensure operational continuity in the delivery of safe, reliable, and sustainable power.

  20. Human DNA repair and recombination genes

    International Nuclear Information System (INIS)

    Thompson, L.H.; Weber, C.A.; Jones, N.J.

    1988-09-01

    Several genes involved in mammalian DNA repair pathways were identified by complementation analysis and chromosomal mapping based on hybrid cells. Eight complementation groups of rodent mutants defective in the repair of uv radiation damage are now identified. At least seven of these genes are probably essential for repair and at least six of them control the incision step. The many genes required for repair of DNA cross-linking damage show overlap with those involved in the repair of uv damage, but some of these genes appear to be unique for cross-link repair. Two genes residing on human chromosome 19 were cloned from genomic transformants using a cosmid vector, and near full-length cDNA clones of each gene were isolated and sequenced. Gene ERCC2 efficiently corrects the defect in CHO UV5, a nucleotide excision repair mutant. Gene XRCC1 normalizes repair of strand breaks and the excessive sister chromatid exchange in CHO mutant EM9. ERCC2 shows a remarkable /approximately/52% overall homology at both the amino acid and nucleotide levels with the yeast RAD3 gene. Evidence based on mutation induction frequencies suggests that ERCC2, like RAD3, might also be an essential gene for viability. 100 refs., 4 tabs