WorldWideScience

Sample records for repair state-of-art imaging

  1. Endovascular aneurysm repair: state-of-art imaging techniques for preoperative planning and surveillance

    DEFF Research Database (Denmark)

    Truijers, M; Resch, T; Van Den Berg, J C

    2009-01-01

    and dual-source CT could reduce radiation dose and obviate the need for nephrotoxic contrast. Up-to-date knowledge of non-invasive vascular imaging and image processing is crucial for EVAR planning and is essential for the development of follow-up programs involving reduced risk of harmful side effects....... dynamic CTA and MRA, provide valuable information on dynamic changes in aneurysm morphology that might have an important impact on endograft selection. During follow-up, imaging of the graft and aneurysm is of utmost importance to identify patients in need of secondary intervention. This has led...... to rigorous follow-up protocols including duplex ultrasound and regular CT examinations. The use of these intense follow-up protocols has recently been questioned because of high radiation dose and the frequent use of nephrotoxic contrast agents. New imaging modalities like contrast enhanced DUS, dynamic MR...

  2. Digital images segmentation: a state of art of the different methods ...

    African Journals Online (AJOL)

    An image is a planar representation of a scene or a 3 D object. The primary information associated to each point of the image is transcribed in grey level or in colour. Image analysis is the set of methods which permits the extraction of pertinent information from the image according to the concerned application, to treat them ...

  3. Terahertz spectroscopy and imaging for cultural heritage management: state of art and perspectives

    Science.gov (United States)

    Catapano, Ilaria; Soldovieri, Francesco

    2014-05-01

    Non-invasive diagnostic tools able to provide information on the materials and preservation state of artworks are crucial to help conservators, archaeologists and anthropologists to plan and carry out their tasks properly. In this frame, technological solutions exploiting Terahertz (THz) radiation, i.e., working at frequencies ranging from 0.1 to 10 THz, are currently deserving huge attention as complementary techniques to classical analysis methodologies based on electromagnetic radiations from X-rays to mid infrared [1]. The main advantage offered by THz spectroscopy and imaging systems is referred to their capability of providing information useful to determine the construction modality, the history life and the conservation state of artworks as well as to identify previous restoration actions [1,2]. In particular, unlike mid- and near-infrared spectroscopy, which provides fingerprint absorption spectra depending on the intramolecular behavior, THz spectroscopy is related to the structure of the molecules of the investigated object. Hence, it can discriminate, for instance, the different materials mixed in a paint [1,2]. Moreover, THz radiation is able to penetrate several materials which are opaque to both visible and infrared materials, such as varnish, paint, plaster, paper, wood, plastic, and so on. Accordingly, it is useful to detect hidden objects and characterize the inner structure of the artwork under test even in the direction of the depth, while avoiding core drillings. In this frame, THz systems allow us to discriminate different layers of materials present in artworks like paints, to obtain images providing information on the construction technique as well as to discover risk factors affecting the preservation state, such as non-visible cracks, hidden molds and air gaps between the paint layer and underlying structure. Furthermore, adopting a no-ionizing radiation, THz systems offer the not trivial benefit of negligible long term risks to the

  4. FIPRED state of art

    International Nuclear Information System (INIS)

    Ohai, D.; Meleg, T.; Dumitrescu, I.; Benga, D.

    2009-01-01

    Full text: The paper presents the FIPRED (Fission Product Release from Debris Bed) Project state of art (UO 2 sintered pellets oxidation). The FIPRED Project is dedicated to the study of the fission products released from irradiated pellets present in debris bed. The fission product release is produced by oxidative self disintegration of sintered pellets at air ingress and it depends on temperature. The experimental program covered experiments of 300-1400 deg. C in air diluted with nitrogen at different concentrations of oxygen and different steam-air mixture. The experiments were performed using the SETARAM thermo-gravimetric equipment and the FIPRED EQ equipment designed and manufactured especially for this type of experiment. The powders (fragments), resulted from UO 2 pellets self disintegration, were characterized by sieving and SEM. The self disintegration mechanism was demonstrated using the experimental result obtained and thermodynamically data of uranium oxides. (authors)

  5. Multimodality imaging and state-of-art GPU technology in discriminating benign from malignant breast lesions on real time decision support system

    International Nuclear Information System (INIS)

    Kostopoulos, S; Glotsos, D; Kalatzis, I; Asvestas, P; Cavouras, D; Sidiropoulos, K; Dimitropoulos, N

    2014-01-01

    The aim of this study was to design a pattern recognition system for assisting the diagnosis of breast lesions, using image information from Ultrasound (US) and Digital Mammography (DM) imaging modalities. State-of-art computer technology was employed based on commercial Graphics Processing Unit (GPU) cards and parallel programming. An experienced radiologist outlined breast lesions on both US and DM images from 59 patients employing a custom designed computer software application. Textural features were extracted from each lesion and were used to design the pattern recognition system. Several classifiers were tested for highest performance in discriminating benign from malignant lesions. Classifiers were also combined into ensemble schemes for further improvement of the system's classification accuracy. Following the pattern recognition system optimization, the final system was designed employing the Probabilistic Neural Network classifier (PNN) on the GPU card (GeForce 580GTX) using CUDA programming framework and C++ programming language. The use of such state-of-art technology renders the system capable of redesigning itself on site once additional verified US and DM data are collected. Mixture of US and DM features optimized performance with over 90% accuracy in correctly classifying the lesions

  6. The "State of Art" of Organisational Blogging

    Science.gov (United States)

    Baxter, Gavin J.; Connolly, Thomas M.

    2013-01-01

    Purpose: The aim of this paper is to provide an overview of the "state of art" of organisational blogging. It also aims to provide a critical review of the literature on organisational blogging and propose recommendations on how to advance the subject area in terms of academic research. Design/methodology/approach: A systematic literature review…

  7. Imaging of cartilage repair procedures

    International Nuclear Information System (INIS)

    Sanghvi, Darshana; Munshi, Mihir; Pardiwala, Dinshaw

    2014-01-01

    The rationale for cartilage repair is to prevent precocious osteoarthritis in untreated focal cartilage injuries in the young and middle-aged population. The gamut of surgical techniques, normal postoperative radiological appearances, and possible complications have been described. An objective method of recording the quality of repair tissue is with the magnetic resonance observation of cartilage repair tissue (MOCART) score. This scoring system evaluates nine parameters that include the extent of defect filling, border zone integration, signal intensity, quality of structure and surface, subchondral bone, subchondral lamina, and records presence or absence of synovitis and adhesions. The five common techniques of cartilage repair currently offered include bone marrow stimulation (microfracture or drilling), mosaicplasty, synthetic resorbable scaffold grafts, osteochondral allograft transplants, and autologous chondrocyte implantation (ACI). Complications of cartilage repair procedures that may be demonstrated on magnetic resonance imaging (MRI) include plug loosening, graft protuberance, graft depression, and collapse in mosaicplasty, graft hypertrophy in ACI, and immune response leading to graft rejection, which is more common with synthetic grafts and cadaveric allografts

  8. Radar rainfall image repair techniques

    Directory of Open Access Journals (Sweden)

    Stephen M. Wesson

    2004-01-01

    Full Text Available There are various quality problems associated with radar rainfall data viewed in images that include ground clutter, beam blocking and anomalous propagation, to name a few. To obtain the best rainfall estimate possible, techniques for removing ground clutter (non-meteorological echoes that influence radar data quality on 2-D radar rainfall image data sets are presented here. These techniques concentrate on repairing the images in both a computationally fast and accurate manner, and are nearest neighbour techniques of two sub-types: Individual Target and Border Tracing. The contaminated data is estimated through Kriging, considered the optimal technique for the spatial interpolation of Gaussian data, where the 'screening effect' that occurs with the Kriging weighting distribution around target points is exploited to ensure computational efficiency. Matrix rank reduction techniques in combination with Singular Value Decomposition (SVD are also suggested for finding an efficient solution to the Kriging Equations which can cope with near singular systems. Rainfall estimation at ground level from radar rainfall volume scan data is of interest and importance in earth bound applications such as hydrology and agriculture. As an extension of the above, Ordinary Kriging is applied to three-dimensional radar rainfall data to estimate rainfall rate at ground level. Keywords: ground clutter, data infilling, Ordinary Kriging, nearest neighbours, Singular Value Decomposition, border tracing, computation time, ground level rainfall estimation

  9. Neutron personal dosimetry: state-of-art

    International Nuclear Information System (INIS)

    Spurný, František

    2005-03-01

    State-of-art of the personal neutron dosimetry is presented, analysed and discussed. Particular attention is devoted to the problems of this type of the dosimetry of external exposure for radiation fields at nuclear power plants. A review of general problems of neutron dosimetry is given and the active individual dosimetry methods available and/or in the stage of development are briefly reviewed. Main attention is devoted to the analysis of the methods available for passive individual neutron dosimetry. The characteristics of these dosemeters were studied and are compared: their energy response functions, detection thresholds and the highest detection limits, the linearity of response, the influence of environmental factors, etc. Particular attention is devoted to their behavior in reactor neutron fields. It is concluded that the choice of the neutron personal dosemeter depends largely on the conditions in which the instrument should be used (neutron spectrum, the level of exposure and the exposure rate, etc.). The results obtained with some of these dosemeters during international intercomparisons are also presented. Particular attention is paid to the personal neutron dosimeter developed and routinely used by National Personal Dosimetry Service Ltd. in the Czech Republic. (author)

  10. State of art in radiation tolerant camera

    Energy Technology Data Exchange (ETDEWEB)

    Choi; Young Soo; Kim, Seong Ho; Cho, Jae Wan; Kim, Chang Hoi; Seo, Young Chil

    2002-02-01

    Working in radiation environment such as nuclear power plant, RI facility, nuclear fuel fabrication facility, medical center has to be considered radiation exposure, and we can implement these job by remote observation and operation. However the camera used for general industry is weakened at radiation, so radiation-tolerant camera is needed for radiation environment. The application of radiation-tolerant camera system is nuclear industry, radio-active medical, aerospace, and so on. Specially nuclear industry, the demand is continuous in the inspection of nuclear boiler, exchange of pellet, inspection of nuclear waste. In the nuclear developed countries have been an effort to develop radiation-tolerant cameras. Now they have many kinds of radiation-tolerant cameras which can tolerate to 10{sup 6}-10{sup 8} rad total dose. In this report, we examine into the state-of-art about radiation-tolerant cameras, and analyze these technology. We want to grow up the concern of developing radiation-tolerant camera by this paper, and upgrade the level of domestic technology.

  11. Umbilical hernia repair - series (image)

    Science.gov (United States)

    ... treatment. The indications for umbilical hernia repair include: incarcerated (strangulated) umbilical hernia defects not spontaneously closed by 4 to 5 years of age children under 2 with very large defects unacceptable to ...

  12. Magnetic Resonance Imaging of Cartilage Repair

    Science.gov (United States)

    Trattnig, Siegfried; Winalski, Carl S.; Marlovits, Stephan; Jurvelin, Jukka S.; Welsch, Goetz H.; Potter, Hollis G.

    2011-01-01

    Articular cartilage lesions are a common pathology of the knee joint, and many patients may benefit from cartilage repair surgeries that offer the chance to avoid the development of osteoarthritis or delay its progression. Cartilage repair surgery, no matter the technique, requires a noninvasive, standardized, and high-quality longitudinal method to assess the structure of the repair tissue. This goal is best fulfilled by magnetic resonance imaging (MRI). The present article provides an overview of the current state of the art of MRI of cartilage repair. In the first 2 sections, preclinical and clinical MRI of cartilage repair tissue are described with a focus on morphological depiction of cartilage and the use of functional (biochemical) MR methodologies for the visualization of the ultrastructure of cartilage repair. In the third section, a short overview is provided on the regulatory issues of the United States Food and Drug Administration (FDA) and the European Medicines Agency (EMEA) regarding MR follow-up studies of patients after cartilage repair surgeries. PMID:26069565

  13. Nuclear and radiation techniques - state of art and development trends

    International Nuclear Information System (INIS)

    Chmielewski, A.G.

    1995-01-01

    The state of art and development trends of nuclear and radiation techniques in Poland and worldwide have been presented. Among them the radiometric gages, radiation technologies, radiotracer methods and measuring systems for pipeline and vessels, brightness control have been described and their applications in industry, agriculture, health and environment protection have been shown and discussed. 35 refs, 1 fig

  14. State of art and perspectives of using renewable energy sources

    International Nuclear Information System (INIS)

    Berkovskij, B.M.; Mikhalevich, A.A.

    1996-01-01

    State of art of renewable energy sources for the beginning of the nineties and perspectives up to 2020 are considered by the forecast of the European Commission. The program of the World Sun Summit up to 1996-2005 is presented

  15. Macro-defect free cements. State of art

    International Nuclear Information System (INIS)

    Holanda, J.N.F.; Povoa, G.E.A.M.; Souza, G.P.; Pinatti, D.G.

    1998-01-01

    The purpose of this work is to prevent a state of art about macro-defect-free cement pastes (MDF cement ) of high mechanical strength. This new type of cement paste is obtained through addition of a water-soluble polymer, followed by intense shear mixing and application of low compacting pressure. It is presented fundamental aspects related to the processing of this MDF paste, as well as its main properties and applications are discussed. (author)

  16. Optimal operation of cogeneration units. State of art and perspective

    International Nuclear Information System (INIS)

    Polimeni, S.

    2001-01-01

    Optimal operation of cogeneration plants and of power plant fueling waste products is a complex challenge as they have to fulfill, beyond the contractual obligation of electric power supply, the constraints of supplying the required thermal energy to the user (for cogeneration units) or to burn completely the by-products of the industrial complex where they are integrated. Electrical power market evolution is pushing such units to a more and more volatile operation caused by uncertain selling price levels. This work intends to pinpoint the state of art in the optimization of these units outlining the important differences among the different size and cycles. The effect of the market liberalization on the automation systems and the optimization algorithms will be discussed [it

  17. Transcatheter Pulmonary Valve Replacement: Current State of Art.

    Science.gov (United States)

    Alkashkari, Wail; Alsubei, Amani; Hijazi, Ziyad M

    2018-03-15

    The past couple of decades have brought tremendous advances to the field of pediatric and adult congenital heart disease (CHD). Percutaneous valve interventions are now a cornerstone of not just the congenital cardiologist treating patients with congenital heart disease, but also-and numerically more importantly-for adult interventional cardiologists treating patients with acquired heart valve disease. Transcatheter pulmonary valve replacement (tPVR) is one of the most exciting recent developments in the treatment of CHD and has evolved to become an attractive alternative to surgery in patients with right ventricular outflow tract (RVOT) dysfunction. This review aims to summarize (1) the current state of the art for tPVR, (2) the expanding indications, and (3) the technological obstacles to optimizing tPVR. Since its introduction in 2000, more than ten thousands tPVR procedures have been performed worldwide. Although the indications for tPVR have been adapted earlier from those accepted for surgical intervention, they remain incompletely defined. The new imaging modalities give better assessment of cardiac anatomy and function and determine candidacy for the procedure. The procedure has been shown to be feasible and safe when performed in patients who received pulmonary conduit and or bioprosthetic valves between the right ventricle and the pulmonary artery. Fewer selected patients post trans-annular patch repair for tetralogy of Fallot may also be candidates for this technology. Size restrictions of the currently available valves limit deployment in the majority of patients post trans-annular patch repair. Newer valves and techniques are being developed that may help such patients. Refinements and further developments of this procedure hold promise for the extension of this technology to other patient populations.

  18. A Critical Analysis of USAir's Image Repair Discourse.

    Science.gov (United States)

    Benoit, William L.; Czerwinski, Anne

    1997-01-01

    Applies the theory of image restoration to a case study of USAir's response to media coverage of a 1994 crash. Argues that introducing such case studies in the classroom helps students to understand the basic tenets of persuasion in the highly charged context of repairing a corporate reputation after an attack. (SR)

  19. Image Repair Discourse and Crisis Communication.

    Science.gov (United States)

    Benoit, William L.

    1997-01-01

    Describes the theory of image restoration discourse as an approach for understanding corporate crisis situations. States this theory can be used by practitioners to help design messages during crises and by critics or educators to critically evaluate such messages. Describes and illustrates the theory's basic concepts. Offers suggestions for…

  20. Magnetic resonance imaging of cartilage and cartilage repair

    International Nuclear Information System (INIS)

    Verstraete, K.L.; Almqvist, F.; Verdonk, P.; Vanderschueren, G.; Huysse, W.; Verdonk, R.; Verbrugge, G.

    2004-01-01

    Magnetic resonance (MR) imaging of articular cartilage has assumed increased importance because of the prevalence of cartilage injury and degeneration, as well as the development of new surgical and pharmacological techniques to treat damaged cartilage. This article will review relevant aspects of the structure and biochemistry of cartilage that are important for understanding MR imaging of cartilage, describe optimal MR pulse sequences for its evaluation, and review the role of experimental quantitative MR techniques. These MR aspects are applied to clinical scenarios, including traumatic chondral injury, osteoarthritis, inflammatory arthritis, and cartilage repair procedures

  1. Magnetic resonance imaging of cartilage and cartilage repair

    Energy Technology Data Exchange (ETDEWEB)

    Verstraete, K.L. E-mail: koenraad.verstraete@ugent.be; Almqvist, F.; Verdonk, P.; Vanderschueren, G.; Huysse, W.; Verdonk, R.; Verbrugge, G

    2004-08-01

    Magnetic resonance (MR) imaging of articular cartilage has assumed increased importance because of the prevalence of cartilage injury and degeneration, as well as the development of new surgical and pharmacological techniques to treat damaged cartilage. This article will review relevant aspects of the structure and biochemistry of cartilage that are important for understanding MR imaging of cartilage, describe optimal MR pulse sequences for its evaluation, and review the role of experimental quantitative MR techniques. These MR aspects are applied to clinical scenarios, including traumatic chondral injury, osteoarthritis, inflammatory arthritis, and cartilage repair procedures.

  2. The state of art of the methods for thermohydraulics design of LMFBR fuel elements

    International Nuclear Information System (INIS)

    Fernandez y Fernandez, E.; Carajilescov, P.

    1981-09-01

    The present (experimental and analytical) state of art of the methods for thermohydraulics design of LMFBR fuel elements is analyzed. A development program is suggested, in order to obtain a computer code for modelling the distribution of coolant enthalpy in reactor core. This computer code is in development. (Author) [pt

  3. Imaging and management of complications of open surgical repair of abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Nayeemuddin, M.; Pherwani, A.D.; Asquith, J.R.

    2012-01-01

    Open repair is still considered the reference standard for long-term repair of abdominal aortic aneurysms (AAA). In contrast to endovascular aneurysm repair (EVAR), patients with open surgical repair of AAA are not routinely followed up with imaging. Although complications following EVAR are widely recognized and routinely identified on follow-up imaging, complications also do occur following open surgical repair. With frequent use of multi-slice computed tomography (CT) angiography (CTA) in vascular patients, there is now improved recognition of the potential complications following open surgical repair. Many of these complications are increasingly being managed using endovascular techniques. The aim of this review is to illustrate a variety of potential complications that may occur following open surgical repair and to demonstrate their management using both surgical and endovascular techniques.

  4. MR imaging of cartilage and its repair in the knee - a review

    International Nuclear Information System (INIS)

    Trattnig, S.; Welsch, G.W.; Domayer, S.; Mosher, T.; Eckstein, F.

    2009-01-01

    Chondral injuries are common lesions of the knee joint, and many patients could benefit from cartilage repair. Widespread cartilage repair techniques require sophisticated noninvasive follow-up using MRI. In addition to the precise morphological assessment of this area of cartilage repair, the cartilage's biochemical constitution can be determined using biochemical MRI techniques. The combination of the clinical outcome after cartilage repair together with the morphological and biochemical description of the cartilage repair tissue as well as the surrounding cartilage can lead to an optimal follow-up evaluation. The present article on MR imaging techniques of cartilage repair focuses on morphological description and scoring using techniques from conventional 2D through advanced isotropic 3D MRI sequences. Furthermore the ultrastructure of the repair tissue and the surrounding cartilage is evaluated in-vivo by biochemical T1-delayed gadolinium enhanced MRI of cartilage (dGEMRIC), T2 relaxation, and diffusion-weighted imaging techniques. (orig.)

  5. Understanding Magnetic Resonance Imaging of Knee Cartilage Repair: A Focus on Clinical Relevance.

    Science.gov (United States)

    Hayashi, Daichi; Li, Xinning; Murakami, Akira M; Roemer, Frank W; Trattnig, Siegfried; Guermazi, Ali

    2017-06-01

    The aims of this review article are (a) to describe the principles of morphologic and compositional magnetic resonance imaging (MRI) techniques relevant for the imaging of knee cartilage repair surgery and their application to longitudinal studies and (b) to illustrate the clinical relevance of pre- and postsurgical MRI with correlation to intraoperative images. First, MRI sequences that can be applied for imaging of cartilage repair tissue in the knee are described, focusing on comparison of 2D and 3D fast spin echo and gradient recalled echo sequences. Imaging features of cartilage repair tissue are then discussed, including conventional (morphologic) MRI and compositional MRI techniques. More specifically, imaging techniques for specific cartilage repair surgery techniques as described above, as well as MRI-based semiquantitative scoring systems for the knee cartilage repair tissue-MR Observation of Cartilage Repair Tissue and Cartilage Repair OA Knee Score-are explained. Then, currently available surgical techniques are reviewed, including marrow stimulation, osteochondral autograft, osteochondral allograft, particulate cartilage allograft, autologous chondrocyte implantation, and others. Finally, ongoing research efforts and future direction of cartilage repair tissue imaging are discussed.

  6. State-of-art report III/1984 (June 29 to November 27, 1984)

    International Nuclear Information System (INIS)

    1985-01-01

    The state-of-art report III/1984 gives a survey of the activities of the Nuclear Committee (KTA) and its panels and of KTA regulation projects in the period between the 35th and 36th KTA meeting. The state-of-art report is designed to give fast, synoptical, adequate information on the current state of KTA work. With regulation projects, data which are subject to miner variations only, for instance concerning the contents or organization of a regulation project, data on the flow of work, members of the panels, are included in the KTA manual. In case of alterations, the data in the KTA manual are updated by replacing the respective pages. (orig./HP) [de

  7. Imaging techniques for the assessment of fracture repair.

    Science.gov (United States)

    Augat, P; Morgan, E F; Lujan, T J; MacGillivray, T J; Cheung, W H

    2014-06-01

    Imaging of a healing fracture provides a non-invasive and often instructive reproduction of the fracture repair progress and the healing status of bone. However, the interpretation of this reproduction is often qualitative and provides only an indirect and surrogate measure of the mechanical stability of the healing fracture. Refinements of the available imaging techniques have been suggested to more accurately determine the healing status of bone. Plain radiographs provide the ability to determine the degree of bridging of the fracture gap and to quantify the amount of periosteal callus formation. Absorptiometric measures including dual X-ray absorptiometry and computed tomography provide quantitative information on the amount and the density of newly formed bone around the site of the fracture. To include the effect of spatial distribution of newly formed bone, finite element models of healing fracture can be employed to estimate its load bearing capacity. Ultrasound technology not only avoids radiation doses to the patients but also provides the ability to additionally measure vascularity in the surrounding soft tissue of the fracture and in the fracture itself. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. An update on synthetic dyes adsorption onto clay based minerals: A state-of-art review

    CSIR Research Space (South Africa)

    Ngulube, T

    2017-04-01

    Full Text Available of Environmental Management An update on synthetic dyes adsorption onto clay based minerals: A state- of-art review Tholiso Ngulube a,*, Jabulani Ray Gumbo b, Vhahangwele Masindi c,d, Arjun Maity e a Department of Ecology and Resources Management..., University of Venda, Private Bag X5050, Thohoyandou, 0950, Limpopo, South Africa b Department of Hydrology and Water Resources, School of Environmental Sciences, University of Venda, Private Bag X5050, Thohoyandou, 0950, Limpopo, South Africa c Council...

  9. CO2 geological sequestration: state of art in Italy and abroad

    International Nuclear Information System (INIS)

    Quattrocchi, Fedora; Bencini, Roberto

    2005-01-01

    This paper proposes a wide scenario on the state of art in Italy and abroad of industrial CO 2 geological sequestration, with particular attention to Weyburn Project. Geochemical monitoring techniques are described, mentioning also geophysical monitoring techniques for CO 2 injected into the soil. Critical choices and objections in Italy to a complete use of clean fossil fuels, hydrogen carrier, clean coal technologies: all of these approaches require geological sequestration of CO 2 [it

  10. The state of art of internal fire PSA in nuclear power plant

    International Nuclear Information System (INIS)

    Yu Xinli; Zhao Bo; Zheng Xiangyang

    2010-01-01

    The operational experiences of nuclear power plants (NPPs) show that the internal fires challenge effectively the nuclear safety of NPPs. Thus, the authorities having jurisdiction in the world have enhanced the supervision on fire safety in NPPs, asking the licensees to perform fire hazard analysis and evaluate the fire risk. This article mainly describes the state of art of internal fire probabilistic safety assessment (PSA) in the world, and compares the main methods and standards for internal fire PSA. (authors)

  11. State-of-art technology of fuels for burning minor actinides. An OECD/NEA study

    International Nuclear Information System (INIS)

    Ogawa, Toru; Konings, R.J.M.; Pillon, S.; Schram, R.P.C.; Verwerft, M.; Wallenius, J.

    2005-01-01

    At OECD/NEA, Working Party on Scientific Issues in Partitioning and Transmutation was formed for 2000-2004, which studied the status and trends of scientific issues in Partitioning and Transmutation (P and T). The study included the scientific and technical issues of fuels and materials, which are related to dedicated systems for transmutation. This paper summarizes the state-of-art technology of the fuels for burning minor actinides (neptunium, americium and curium). (author)

  12. Description of occupant behaviour in building energy simulation: state-of-art and concepts for improvements

    DEFF Research Database (Denmark)

    Fabi, Valentina; Andersen, Rune Vinther; Corgnati, Stefano Paolo

    2011-01-01

    of basic assumptions that affect the results. Therefore, the calculated energy performance may differ significantly from the real energy consumption. One of the key reasons is the current inability to properly model occupant behaviour and to quantify the associated uncertainties in building performance...... predictions. By consequence, a better description of parameters related to occupant behaviour is highly required. In this paper, the state of art in occupant behaviour modelling within energy simulation tools is analysed and some concepts related to possible improvements of simulation tools are proposed...

  13. State of art survey for design of medium frequency high power transformer

    DEFF Research Database (Denmark)

    Vaisambhayana, Sriram; Dincan, Catalin; Shuyu, Cao

    2016-01-01

    Medium and high frequency, high power transformers play an important role in footprint reduction along with their functions of galvanic isolation, and voltage transformation in all high power converters typically used in traction power systems, offshore wind plant power converters, and solid state...... transformer based distribution system grids. This state of art report analysis the various materials and design tradeoffs that govern the electromagnetic behavior and loss mechanisms of the medium frequency transformer applications. Typical winding and core geometries that have been reported extensively...

  14. Energy demand’s state of art until the first lustrum of the 90s.

    Directory of Open Access Journals (Sweden)

    Néstor Juan Sanabria Landazábal

    2008-07-01

    Full Text Available The change in the theoretical ways to understand the phenomena is coupled with the complexity that they develop by themselves. At the same time, instrumental ways needed to measure are being developed. So it is possible to see substantive changes in the way to measure the demand for residential electric power. It will move from large aggregates to the use of microdata. From a functional log-linear form to the incorporation of the asymmetries, through the binary choice and design that made that the power is equivalent to an intermediate service as it serves to produce goods or services at home. It was also reported a widespread use of time series and co integration analysis. But even at the time this state of art is described, many of the themes of this type of demand are not solved and developments after 1994, in Colombia will give another meaning to the use of electricity.

  15. Sonography compared with MR imaging in the evaluation of card tethering following myelomeningocele repair

    International Nuclear Information System (INIS)

    Newman, B.; Bowen, A.; Albright, L.

    1989-01-01

    This paper reports on MR imaging and videotaped US spine examinations to evaluate cord tethering were retrospectively compared in 12 children with prior myelomeningocele repair and correlated with clinical and surgical findings. Although US did not delineate normal or abnormal anatomy as well as MR imaging, both types of studies confirmed the presence of tethering in 10 patients. One child with a normal US examination and abnormal MR images had tethering confirmed surgically. A second child had a US study suggestive of tethering with equivocal MR images. Postoperative studies in eight patients correlated less well; US suggested persistent tethering in five patients and MR imaging indicated tethering in two

  16. State of Art About water Uses and Waste water Management in Lebanon

    International Nuclear Information System (INIS)

    Geara, D.; Moilleron, R.; Lorgeoux, C.; El Samarani, A.; Chebbo, Gh.

    2010-01-01

    This paper shows the real situation about management of water and waste water in Lebanon and focuses on problems related to urban water pollution released in environment. Water and waste water infrastructures have been rebuilt since 1992. However, waste water management still remains one of the greatest challenges facing Lebanese people, since water supply projects have been given priority over wastewater projects. As a consequence of an increased demand of water by agricultural, industrial and household sectors in the last decade, waste water flows have been increased. In this paper, the existing waste water treatment plants (WWTP) operating in Lebanon are presented. Most of them are small-scale community-based ones, only two large-scale plants, constructed by the government, are currently operational. Lebanese aquatic ecosystems are suffering from the deterioration of water quality because of an insufficient treatment of waste water, which is limited mostly to pre-treatment processes. In fact, domestic and industrial effluents are mainly conducted together in the sewer pipes to the WWTP before being discharged, without adequate treatment into the rivers or directly into the Mediterranean Sea. Such discharges are threatening the coastal marine ecosystem in the Mediterranean basin. This paper aims at giving the current state of knowledge about water uses and wastewater management in Lebanon. The main conclusion drawn from this state of art is a lack of data. In fact, the available data are limited to academic research without being representative on a national scale. (author)

  17. Nuclear and radiation techniques - state of art and development trends; Techniki jadrowe i radiacyjne - stan obecny oraz kierunki rozwoju

    Energy Technology Data Exchange (ETDEWEB)

    Chmielewski, A.G. [Institute of Nuclear Chemistry and Technology, Warsaw (Poland)

    1995-12-31

    The state of art and development trends of nuclear and radiation techniques in Poland and worldwide have been presented. Among them the radiometric gages, radiation technologies, radiotracer methods and measuring systems for pipeline and vessels, brightness control have been described and their applications in industry, agriculture, health and environment protection have been shown and discussed. 35 refs, 1 fig.

  18. Evaluation of native hyaline cartilage and repair tissue after two cartilage repair surgery techniques with 23Na MR imaging at 7 T: initial experience.

    Science.gov (United States)

    Zbýň, S; Stelzeneder, D; Welsch, G H; Negrin, L L; Juras, V; Mayerhoefer, M E; Szomolanyi, P; Bogner, W; Domayer, S E; Weber, M; Trattnig, S

    2012-08-01

    To compare the sodium normalized mean signal intensity (NMSI) values between patients after bone marrow stimulation (BMS) and matrix-associated autologous chondrocyte transplantation (MACT) cartilage repair procedures. Nine BMS and nine MACT patients were included. Each BMS patient was matched with one MACT patient according to age [BMS 36.7 ± 10.7 (mean ± standard deviation) years; MACT 36.9 ± 10.0 years], postoperative interval (BMS 33.5 ± 25.3 months; MACT 33.2 ± 25.7 months), and defect location. All magnetic resonance imaging (MRI) measurements were performed on a 7 T system. Proton images served for morphological evaluation of repair tissue using the magnetic resonance observation of cartilage repair tissue (MOCART) scoring system. Sodium NMSI values in the repair area and morphologically normal cartilage were calculated. Clinical outcome was assessed right after MRI. Analysis of covariance, t-tests, and Pearson correlation coefficients were evaluated. Sodium NMSI was significantly lower in BMS (P = 0.004) and MACT (P = 0.006) repair tissue, compared to reference cartilage. Sodium NMSI was not different between the reference cartilage in MACT and BMS patients (P = 0.664), however it was significantly higher in MACT than in BMS repair tissue (P = 0.028). Better clinical outcome was observed in BMS than in MACT patients. There was no difference between MOCART scores for MACT and BMS patients (P = 0.915). We did not observe any significant correlation between MOCART score and sodium repair tissue NMSI (r = -0.001; P = 0.996). Our results suggest higher glycosaminoglycan (GAG) content, and therefore, repair tissue of better quality in MACT than in BMS patients. Sodium imaging might be beneficial in non-invasive evaluation of cartilage repair surgery efficacy. Copyright © 2012 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  19. Quality Improvement Guidelines for Imaging Detection and Treatment of Endoleaks following Endovascular Aneurysm Repair (EVAR)

    International Nuclear Information System (INIS)

    Rand, T.; Uberoi, R.; Cil, B.; Munneke, G.; Tsetis, D.

    2013-01-01

    Major concerns after aortic aneurysm repair are caused by the presence of endoleaks, which are defined as persistent perigraft flow within the aortic aneurysm sac. Diagnosis of endoleaks can be performed with various imaging modalities, and indications for treatment are based on further subclassifications. Early detection and correct classification of endoleaks are crucial for planning patient management. The vast majority of endoleaks can be treated successfully by interventional means. Guidelines for Imaging Detection and Treatment of endoleaks are described in this article.

  20. Rare earth elements in human and animal health: State of art and research priorities

    Energy Technology Data Exchange (ETDEWEB)

    Pagano, Giovanni, E-mail: gbpagano@tin.it [University of Naples “Federico II”, Environmental Hygiene, via Cinthia, I-80126 Naples (Italy); Aliberti, Francesco; Guida, Marco [University of Naples “Federico II”, Environmental Hygiene, via Cinthia, I-80126 Naples (Italy); Oral, Rahime [Ege University, Faculty of Fisheries, TR-35100 Bornova, İzmir (Turkey); Siciliano, Antonietta [University of Naples “Federico II”, Environmental Hygiene, via Cinthia, I-80126 Naples (Italy); Trifuoggi, Marco [University of Naples “Federico II”, Department of Chemical Sciences, I-80126 Naples (Italy); Tommasi, Franca [“Aldo Moro” Bari University, Department of Biology, I-70126 Bari (Italy)

    2015-10-15

    Background: A number of applications have been developed using rare earth elements (REE), implying several human exposures and raising unsolved questions as to REE-associated health effects. Methods: A MedLine survey was retrieved from early reports (1980s) up to June 2015, focused on human and animal exposures to REE. Literature from animal models was selected focusing on REE-associated health effects. Results: Some REE occupational exposures, in jobs such as glass polishers, photoengravers and movie projectionists showed a few case reports on health effects affecting the respiratory system. No case-control or cohort studies of occupational REE exposures were retrieved. Environmental exposures have been biomonitored in populations residing in REE mining areas, showing REE accumulation. The case for a iatrogenic REE exposure was raised by the use of gadolinium-based contrast agents for nuclear magnetic resonance. Animal toxicity studies have shown REE toxicity, affecting a number of endpoints in liver, lungs and blood. On the other hand, the use of REE as feed additives in livestock is referred as a safe and promising device in zootechnical activities, possibly suggesting a hormetic effect both known for REE and for other xenobiotics. Thus, investigations on long-term exposures and observations are warranted. Conclusion: The state of art provides a limited definition of the health effects in occupationally or environmentally REE-exposed human populations. Research priorities should be addressed to case-control or cohort studies of REE-exposed humans and to life-long animal experiments. - Highlights: • An extensive number of activities have been developed utilizing rare earth elements (REE). • The literature of REE-associated health effects in humans, and on animal studies is reviewed. • The main literature gaps are discussed, in epidemiological and in animal studies. • Prospects studies are suggested, aimed at evaluating long-term effects of REE exposures

  1. Rare earth elements in human and animal health: State of art and research priorities

    International Nuclear Information System (INIS)

    Pagano, Giovanni; Aliberti, Francesco; Guida, Marco; Oral, Rahime; Siciliano, Antonietta; Trifuoggi, Marco; Tommasi, Franca

    2015-01-01

    Background: A number of applications have been developed using rare earth elements (REE), implying several human exposures and raising unsolved questions as to REE-associated health effects. Methods: A MedLine survey was retrieved from early reports (1980s) up to June 2015, focused on human and animal exposures to REE. Literature from animal models was selected focusing on REE-associated health effects. Results: Some REE occupational exposures, in jobs such as glass polishers, photoengravers and movie projectionists showed a few case reports on health effects affecting the respiratory system. No case-control or cohort studies of occupational REE exposures were retrieved. Environmental exposures have been biomonitored in populations residing in REE mining areas, showing REE accumulation. The case for a iatrogenic REE exposure was raised by the use of gadolinium-based contrast agents for nuclear magnetic resonance. Animal toxicity studies have shown REE toxicity, affecting a number of endpoints in liver, lungs and blood. On the other hand, the use of REE as feed additives in livestock is referred as a safe and promising device in zootechnical activities, possibly suggesting a hormetic effect both known for REE and for other xenobiotics. Thus, investigations on long-term exposures and observations are warranted. Conclusion: The state of art provides a limited definition of the health effects in occupationally or environmentally REE-exposed human populations. Research priorities should be addressed to case-control or cohort studies of REE-exposed humans and to life-long animal experiments. - Highlights: • An extensive number of activities have been developed utilizing rare earth elements (REE). • The literature of REE-associated health effects in humans, and on animal studies is reviewed. • The main literature gaps are discussed, in epidemiological and in animal studies. • Prospects studies are suggested, aimed at evaluating long-term effects of REE exposures

  2. Accuracy of different imaging modalities prior to biventricular repair ...

    African Journals Online (AJOL)

    Arun Kumar Agnihotri

    catheterization with invasive angiocardiography is indicated when the PA ... arterial and venous imaging.3,4. The major ... history of aorto-pulmonary shunt awaiting bi-ventricular ..... regarding the central and peripheral PAs, APCs as well as in ...

  3. An experimental study on the application of radionuclide imaging in repair of the bone defect

    Directory of Open Access Journals (Sweden)

    Weimin Zhu

    2011-08-01

    Full Text Available The aim of our study was to validate the effect of radionuclide imaging in early monitoring of the bone’s reconstruction, the animal model of bone defect was made on the rabbits repaired with HA artificial bone. The ability of bone defect repair was evaluated by using radionuclide bone imaging at 2, 4, 8 and 12 weeks postoperatively. The results indicate that the experimental group stimulated more bone formation than that of the control group. The differences of the bone reconstruction ability were statistically significant (p<0.05. The nano-HA artificial has good bone conduction, and it can be used for the treatment of bone defects. Radionuclide imaging may be an effective and first choice method for the early monitoring of the bone’s reconstruction.

  4. Crisis strategies in BP's Deepwater Horizon response : An image repair and situational crisis communication study

    OpenAIRE

    Johansson, Mikael

    2017-01-01

    The BP Deepwater Horizon crisis in 2010 was one the largest catastrophes in the history of the oil industry. BP was sued over the disaster, and lost several billion dollars. This study examines the crisis response strategies and/or image repair strategies, which can be found in BP's press releases following the Deepwater Horizon crisis. In particular, the study looks closer at what established crisis communication strategies could be discerned in the material, and how they are used discursive...

  5. Technical aspects of the Space Telescope Imaging Spectrograph Repair (STIS-R)

    Science.gov (United States)

    Rinehart, S. A.; Domber, J.; Faulkner, T.; Gull, T.; Kimble, R.; Klappenberger, M.; Leckrone, D.; Niedner, M.; Proffitt, C.; Smith, H.; Woodgate, B.

    2008-07-01

    In August 2004, the Hubble Space Telescope (HST) Space Telescope Imaging Spectrograph (STIS) ceased operation due to a failure of the 5V mechanism power converter in the Side 2 Low Voltage Power Supply (LVPS2). The failure precluded movement of any STIS mechanism and, because of the earlier (2001) loss of the Side 1 electronics chain, left the instrument shuttered and in safe mode after 7.5 years of science operations. A team was assembled to analyze the fault and to determine if STIS repair (STIS-R) was feasible. The team conclusively pinpointed the Side 2 failure to the 5V mechanism converter, and began studying EVA techniques for opening STIS during Servicing Mission 4 (SM4) to replace the failed LVPS2 board. The restoration of STIS functionality via surgical repair by astronauts has by now reached a mature and final design state, and will, along with a similar repair procedure for the Advanced Camera for Surveys (ACS), represent a first for Hubble servicing. STIS-R will restore full scientific functionality of the spectrograph on Side 2, while Side 1 will remain inoperative. Because of the high degree of complementarity between STIS and the new Cosmic Origins Spectrograph (COS, to be installed during SM4)), successful repair of the older spectrograph is an important scientific objective. In this presentation, we focus on the technical aspects associated with STIS-R.

  6. Definition of pertinent parameters for the evaluation of articular cartilage repair tissue with high-resolution magnetic resonance imaging

    International Nuclear Information System (INIS)

    Marlovits, Stefan; Striessnig, Gabriele; Resinger, Christoph T.; Aldrian, Silke M.; Vecsei, Vilmos; Imhof, Herwig; Trattnig, Siegfried

    2004-01-01

    To evaluate articular cartilage repair tissue after biological cartilage repair, we propose a new technique of non-invasive, high-resolution magnetic resonance imaging (MRI) and define a new classification system. For the definition of pertinent variables the repair tissue of 45 patients treated with three different techniques for cartilage repair (microfracture, autologous osteochondral transplantation, and autologous chondrocyte transplantation) was analyzed 6 and 12 months after the procedure. High-resolution imaging was obtained with a surface phased array coil placed over the knee compartment of interest and adapted sequences were used on a 1 T MRI scanner. The analysis of the repair tissue included the definition and rating of nine pertinent variables: the degree of filling of the defect, the integration to the border zone, the description of the surface and structure, the signal intensity, the status of the subchondral lamina and subchondral bone, the appearance of adhesions and the presence of synovitis. High-resolution MRI, using a surface phased array coil and specific sequences, can be used on every standard 1 or 1.5 T MRI scanner according to the in-house standard protocols for knee imaging in patients who have had cartilage repair procedures without substantially prolonging the total imaging time. The new classification and grading system allows a subtle description and suitable assessment of the articular cartilage repair tissue

  7. Real-time fluorescence imaging of the DNA damage repair response during mitosis.

    Science.gov (United States)

    Miwa, Shinji; Yano, Shuya; Yamamoto, Mako; Matsumoto, Yasunori; Uehara, Fuminari; Hiroshima, Yukihiko; Toneri, Makoto; Murakami, Takashi; Kimura, Hiroaki; Hayashi, Katsuhiro; Yamamoto, Norio; Efimova, Elena V; Tsuchiya, Hiroyuki; Hoffman, Robert M

    2015-04-01

    The response to DNA damage during mitosis was visualized using real-time fluorescence imaging of focus formation by the DNA-damage repair (DDR) response protein 53BP1 linked to green fluorescent protein (GFP) (53BP1-GFP) in the MiaPaCa-2(Tet-On) pancreatic cancer cell line. To observe 53BP1-GFP foci during mitosis, MiaPaCa-2(Tet-On) 53BP1-GFP cells were imaged every 30 min by confocal microscopy. Time-lapse imaging demonstrated that 11.4 ± 2.1% of the mitotic MiaPaCa-2(Tet-On) 53BP1-GFP cells had increased focus formation over time. Non-mitotic cells did not have an increase in 53BP1-GFP focus formation over time. Some of the mitotic MiaPaCa-2(Tet-On) 53BP1-GFP cells with focus formation became apoptotic. The results of the present report suggest that DNA strand breaks occur during mitosis and undergo repair, which may cause some of the mitotic cells to enter apoptosis in a phenomenon possibly related to mitotic catastrophe. © 2014 Wiley Periodicals, Inc.

  8. Evaluation of cartilage repair tissue in the knee and ankle joint using sodium magnetic resonance imaging at 7 Tesla

    International Nuclear Information System (INIS)

    Zbyn, S.

    2015-01-01

    Articular cartilage of adults shows no or very limited intrinsic capacity for self-repair. Since untreated chondral defects often progress to osteoarthritis, symptomatic defects should be treated. Different cartilage repair procedures have been developed with the goal to restore joint function and prevent further cartilage degeneration by providing repair tissue of the same structure, composition, and biomechanical properties as native cartilage. Various cartilage repair procedures have been developed; including bone marrow stimulation (BMS) techniques such as microfracture (MFX), cell-based techniques such as matrix-associated autologous chondrocyte transplantation (MACT), and others. Since biopsies of cartilage repair tissue are invasive and cannot be repeated, a noninvasive method is needed that could follow-up the quality of cartilage and repair tissue. Negatively charged glycosaminoglycans (GAG) are very important for cartilage function as they attract positive ions such as sodium. The high concentration of ions in cartilage is responsible for osmotic pressure providing cartilage its resilience to compression. Since GAGs are counterbalanced by sodium ions, sodium magnetic resonance imaging (MRI) was validated as a sensitive method for the in vivo evaluation of GAG concentration in native cartilage but not for repair tissue. Thus, the main goal of this thesis was to optimize and validate sodium 7 Tesla MRI for the evaluation of cartilage repair tissue quality in patients after different cartilage repair surgeries in the knee and ankle joint. In our studies, sodium MRI was used for the first time for the clinical evaluation of cartilage repair tissue. A strong correlation found between sodium imaging and dGEMRIC (another GAG-sensitive technique) in patients after MACT on femoral cartilage proved sensitivity of sodium MRI to GAG changes in native cartilage and repair tissue in vivo. Comparison between BMS and MACT patients showed significantly lower sodium values

  9. Image repair-theory vid livsmedelskris : Textanalys av Findus kriskommunikation kring hästköttsskandalen

    OpenAIRE

    Hallström, Jenny; Georgenson, Maria

    2013-01-01

    This study intends to use a text analysis and analyze Findus crisis communication, on their website, about the horse meat scandal in February and March 2013. The main focus is to examine if Findus crisis communication can be connected to Beniot’s image repair strategies and the rhetorical appeal forms, in five press releases and four blog posts, and also if they are different depending on the media format. The results show that Findus usually used three of the five image repair strategies and...

  10. Technical and instrumental prerequisites for single-port laparoscopic solo surgery: state of art.

    Science.gov (United States)

    Kim, Say-June; Lee, Sang Chul

    2015-04-21

    With the aid of advanced surgical techniques and instruments, single-port laparoscopic surgery (SPLS) can be accomplished with just two surgical members: an operator and a camera assistant. Under these circumstances, the reasonable replacement of a human camera assistant by a mechanical camera holder has resulted in a new surgical procedure termed single-port solo surgery (SPSS). In SPSS, the fixation and coordinated movement of a camera held by mechanical devices provides fixed and stable operative images that are under the control of the operator. Therefore, SPSS primarily benefits from the provision of the operator's eye-to-hand coordination. Because SPSS is an intuitive modification of SPLS, the indications for SPSS are the same as those for SPLS. Though SPSS necessitates more actions than the surgery with a human assistant, these difficulties seem to be easily overcome by the greater provision of static operative images and the need for less lens cleaning and repositioning of the camera. When the operation is expected to be difficult and demanding, the SPSS process could be assisted by the addition of another instrument holder besides the camera holder.

  11. Endovascular aneurysm repair (EVAR) follow-up imaging: the assessment and treatment of common postoperative complications

    International Nuclear Information System (INIS)

    Ilyas, S.; Shaida, N.; Thakor, A.S.; Winterbottom, A.; Cousins, C.

    2015-01-01

    Endovascular abdominal aortic aneurysm repair (EVAR) is a well-established procedure, which has long-term mortality rates similar to that of open repair. It has the additional benefit of being less invasive, making it the favoured method of treating abdominal aortic aneurysms in elderly and high-risk patients with multiple co-morbidities. The main disadvantage of EVAR is the higher rate of re-intervention, due to device-related complications, including endoleaks, limb occlusion, stent migration, kinking, and infection. As a result lifelong surveillance is required. In order to avoid missing these complications, intricate knowledge of stent graft design, good-quality diagnostic ultrasound skills, multiplanar reformatting of CT images, and reproducible investigations are important. Most of these complications can be treated via an endovascular approach using cuff extensions, uncovered stents, coils, and liquid embolic agents. Open surgery is reserved for complex complications, where an endovascular approach is not feasible. - Highlights: • Comprehensive pictorial review of EVAR related complications. • Importance of life-long EVAR surveillance, to prevent aortic rupture or lower limb ischaemia. • Identification and management of endoleaks, rupture, migration, kink/infolding, occlusion and infection

  12. State of art: Optically stimulated luminescence dosimetry – Frontiers of future research

    International Nuclear Information System (INIS)

    Yukihara, Eduardo G.; McKeever, Stephen W.S.; Akselrod, Mark S.

    2014-01-01

    Since the commercial adoption of the optically stimulated luminescence (OSL) technique in dosimetry, almost 20 years ago, we have seen major advances in the deployment of OSL dosimeters in different areas, including personal, medical, and space dosimetry. The objective of this paper is to provide a critical overlook at the OSL technique from three different points of view: strengths, challenges and opportunities. We discuss factors that made the OSL technique successful: its simplicity, accuracy, wide dynamic range of measured dose, ease for automation, re-read capability, ability to perform imaging, and the availability of diverse instruments and materials. We look into problems that were overcome and others that remain in several areas of new applications into which OSL has expanded in the past 10 years, such as medical, space, neutron and accident dosimetry. Finally, we discuss unexplored possibilities, new driving forces, and open questions. We hope the broad overview presented here will encourage more discussion and stimulate the research that will advance our fundamental understanding of the OSL process. - Highlights: • Critical overlook of the OSL technique is presented. • Factors that made the OSL technique successful are discussed. • New applications in medical, space and accident dosimetry are discussed. • Unexplored possibilities, new driving forces, and open questions are presented

  13. State of art and next challenges in instrumentation for quality control in hadron therapy centres

    International Nuclear Information System (INIS)

    Karkar, S.; Pauna, N.; Testa, E.

    2008-01-01

    The in-beam positron emission tomography (PET) is currently the only feasible non-invasive method for in-situ monitoring of tumour treatments with ion beams. It is able of assessing parameters relevant for quality assurance, i.e. the particle range in tissue, the position of the irradiated volume and the local deviations between planned and applied distributions. It was used for the first time for quality assurance at GSI hadron-therapy center since 1997: the acquisition is performed during the irradiation and some minutes afterwards which allows the detection of both short-lived and long-lived isotopes and avoids to move the patient. Moreover we can imagine that such in-line PET could be improved to become an on-line PET in conditions that number of LOR detected (Lines of Responses) is large enough and time of reconstruction is short enough to provide typically an image every tens of seconds. The objectives pursued with the present work are to outline present limitations and future challenges of in-beam PET instrumentation. The aim of Part I is to present the prerequisites for a in-beam PET system as well as recent studies to optimise the detector geometry and its performances (by testing modern gamma ray detectors) as well as data processing methods (including adapted reconstruction methods for PET data).In Part II, in-beam and on-line PET challenges are identified. Performances of new fast scintillators and photodetectors are presented in correlation with expected tasks for an optimal delivered dose monitoring. The need of additional simulations for estimating the feasibility of a real time PET camera is obvious. This part also includes a discussion about the possibility of using gamma prompt radiation as a monitor of the dose inside patient under certain conditions

  14. State of art and next challenges in instrumentation for quality control in hadron therapy centres

    Energy Technology Data Exchange (ETDEWEB)

    Karkar, S. [Aix-Marseille Univ., CNRS/IN2P3, Centre de Physique des Particules de Marseille, CPPM, 13 - Marseille (France); Pauna, N. [Universite Blaise Pascal, CNRS/IN2P3, Lab. de Physique Corpusculaire (LPC) Clermont, 63 - Aubiere (France); Testa, E. [Lyon-1 Univ., CNRS/IN2P3, Institut de Physique Nucleaire de Lyon (IPNL), 69 - Villeurbanne (France)

    2008-07-01

    The in-beam positron emission tomography (PET) is currently the only feasible non-invasive method for in-situ monitoring of tumour treatments with ion beams. It is able of assessing parameters relevant for quality assurance, i.e. the particle range in tissue, the position of the irradiated volume and the local deviations between planned and applied distributions. It was used for the first time for quality assurance at GSI hadron-therapy center since 1997: the acquisition is performed during the irradiation and some minutes afterwards which allows the detection of both short-lived and long-lived isotopes and avoids to move the patient. Moreover we can imagine that such in-line PET could be improved to become an on-line PET in conditions that number of LOR detected (Lines of Responses) is large enough and time of reconstruction is short enough to provide typically an image every tens of seconds. The objectives pursued with the present work are to outline present limitations and future challenges of in-beam PET instrumentation. The aim of Part I is to present the prerequisites for a in-beam PET system as well as recent studies to optimise the detector geometry and its performances (by testing modern gamma ray detectors) as well as data processing methods (including adapted reconstruction methods for PET data).In Part II, in-beam and on-line PET challenges are identified. Performances of new fast scintillators and photodetectors are presented in correlation with expected tasks for an optimal delivered dose monitoring. The need of additional simulations for estimating the feasibility of a real time PET camera is obvious. This part also includes a discussion about the possibility of using gamma prompt radiation as a monitor of the dose inside patient under certain conditions.

  15. Cell tracking in cardiac repair: What to image and how to image

    NARCIS (Netherlands)

    A. Ruggiero (Alessandro); D.L.J. Thorek (Daniel L.J.); J. Guenoun (Jamal); G.P. Krestin (Gabriel); M.R. Bernsen (Monique)

    2012-01-01

    textabstractStem cell therapies hold the great promise and interest for cardiac regeneration among scientists, clinicians and patients. However, advancement and distillation of a standard treatment regimen are not yet finalised. Into this breach step recent developments in the imaging biosciences.

  16. Rhetorical Approaches to Crisis Communication: The Research, Development, and Validation of an Image Repair Situational Theory for Educational Leaders

    Science.gov (United States)

    Vogelaar, Robert J.

    2005-01-01

    In this project a product to aid educational leaders in the process of communicating in crisis situations is presented. The product was created and received a formative evaluation using an educational research and development methodology. Ultimately, an administrative training course that utilized an Image Repair Situational Theory was developed.…

  17. Endovascular Aneurysm Repair: Is Imaging Surveillance Robust, and Does It Influence Long-term Mortality?

    Energy Technology Data Exchange (ETDEWEB)

    Waduud, Mohammed Abdul, E-mail: m.a.waduud@doctors.org.uk [Glasgow Royal Infirmary, Department of Surgery (United Kingdom); Choong, Wen Ling, E-mail: wenlingchoong@nhs.net [Aberdeen Royal Infirmary, NHS Grampian, Department of Surgery (United Kingdom); Ritchie, Moira, E-mail: moirasim9@gmail.com; Williams, Claire, E-mail: c.williams.3@research.gla.ac.uk [University of Glasgow, Institute of Health and Wellbeing Glasgow (United Kingdom); Yadavali, Reddi, E-mail: reddi.yadavali@nhs.net [Aberdeen Royal Infirmary, NHS Grampian, Department of Radiology (United Kingdom); Lim, Shueh, E-mail: s.lim.06@aberdeen.ac.uk [Royal Infirmary of Edinburgh, NHS Lothian, Department of Radiology (United Kingdom); Buchanan, Fraser, E-mail: f.buchanan.11@aberdeen.ac.uk [University of Aberdeen, The School of Medicine and Dentistry (United Kingdom); Bhat, Raj, E-mail: raj.bhat@nhs.net [Ninewells Hospital, NHS Tayside, Department of Radiology (United Kingdom); Ramanathan, Krishnappan, E-mail: k.ramanathan@dundee.ac.uk [University of Dundee, School of Medicine (United Kingdom); Ingram, Susan, E-mail: susan.ingram@luht.scot.nhs.uk; Cormack, Laura, E-mail: lgcormack@googlemail.com [Royal Infirmary of Edinburgh, NHS Lothian, Department of Radiology (United Kingdom); Moss, Jonathan G., E-mail: jon.moss@ggc.scot.nhs.uk [Gartnavel General Hospital, Department of Radiology (United Kingdom)

    2015-02-15

    PurposeEndovascular aneurysm repair (EVAR) is the dominant treatment strategy for abdominal aortic aneurysms. However, as a result of uncertainty regarding long-term durability, an ongoing imaging surveillance program is required. The aim of the study was to assess EVAR surveillance in Scotland and its effect on all-cause and aneurysm-related mortality.MethodsA retrospective analysis of all EVAR procedures carried out in the four main Scottish vascular units. The primary outcome measure was the implementation of post-EVAR imaging surveillance across Scotland. Patients were identified locally and then categorized as having complete, incomplete, or no surveillance. Secondary outcome measures were all-cause mortality and aneurysm-related mortality. Cause of death was obtained from death certificates.ResultsData were available for 569 patients from the years 2001 to 2012. All centers had data for a minimum of 5 contiguous years. Surveillance ranged from 1.66 to 4.55 years (median 3.03 years). Overall, 53 % had complete imaging surveillance, 43 % incomplete, and 4 % none. For the whole cohort, all-cause 5-year mortality was 33.5 % (95 % confidence interval 28.0–38.6) and aneurysm-related mortality was 4.5 % (.8–7.3). All-cause mortality in patients with complete, incomplete, and no imaging was 49.9 % (39.2–58.6), 19.1 % (12.6–25.2), and 47.2 % (17.7–66.2), respectively. Aneurysm-related mortality was 3.7 % (1.8–7.4), 4.4 % (2.2–8.9), and 9.5 % (2.5–33.0), respectively. All-cause mortality was significantly higher in patients with complete compared to incomplete imaging surveillance (p < 0.001). No significant differences were observed in aneurysm-related mortality (p = 0.2).ConclusionOnly half of EVAR patients underwent complete long-term imaging surveillance. However, incomplete imaging could not be linked to any increase in mortality. Further work is required to establish the role and deliverability of EVAR imaging surveillance.

  18. Model System for Live Imaging of Neuronal Responses to Injury and Repair

    Directory of Open Access Journals (Sweden)

    Mathieu Gravel

    2011-11-01

    Full Text Available Although it has been well established that induction of growth-associated protein-43 (GAP-43 during development coincides with axonal outgrowth and early synapse formation, the existence of neuronal plasticity and neurite outgrowth in the adult central nervous system after injuries is more controversial. To visualize the processes of neuronal injury and repair in living animals, we generated reporter mice for bioluminescence and fluorescence imaging bearing the luc (luciferase and gfp (green fluorescent protein reporter genes under the control of the murine GAP-43 promoter. Reporter functionality was first observed during the development of transgenic embryos. Using in vivo bioluminescence and fluorescence imaging, we visualized induction of the GAP-43 signals from live embryos starting at E10.5, as well as neuronal responses to brain and peripheral nerve injuries (the signals peaked at 14 days postinjury. Moreover, three-dimensional analysis of the GAP-43 bioluminescent signal confirmed that it originated from brain structures affected by ischemic injury. The analysis of fluorescence signal at cellular level revealed colocalization between endogenous protein and the GAP-43-driven gfp transgene. Taken together, our results suggest that the GAP-43-luc/gfp reporter mouse represents a valid model system for real-time analysis of neurite outgrowth and the capacity of the adult nervous system to regenerate after injuries.

  19. State-of-art report on digital I and C system reliability issues for nuclear power plants

    International Nuclear Information System (INIS)

    Hwang, In Koo; Lee, Dong Gyoung; Cha, Kyung Ho; Kwon, Kee Choon; Wood, Richard T.

    2000-01-01

    As the instrumentation and control (Iand C) equipment suppliers tend to provide digital components rather than conventional analog type components for instrument and control systems of nuclear power plants(NPPs), it is unavoidable to adopt digital equipment for safety I and C systems as well as non-safety systems. However, the full introduction of digital equipment to I and C systems of nuclear power plants raises several concerns which have not been considered for conventional analog I and C systems. The two major examples of the issues of digital systems are electromagnetic compatibility (EMC) and software reliability. KAERI invited a technical expert, Dr. Richard T. Wood, from Oak Ridge National Laboratory (ORNL) in Unites States and held seminars to recognize the state-of-art of the above issues and to share the information on techniques dealing with the problems. Dr. Wood has been working on the development of EMC guidelines and technical basis in using digital equipment for safety systems in nuclear power plants on the sponsorship of US Nuclear Regulatory Commission (NRC). Being based on his statements and discussions during his visit, this report describes technical considerations and issues on digital safety I and C system application in NPPs, EMC methods, environmental effects vulnerable to digital components, reliability assurance methods, etc. (author)

  20. Lecithin-based nanostructured gels for skin delivery: an update on state of art and recent applications.

    Science.gov (United States)

    Elnaggar, Yosra S R; El-Refaie, Wessam M; El-Massik, Magda A; Abdallah, Ossama Y

    2014-04-28

    Conventional carriers for skin delivery encounter obstacles of drug leakage, scanty permeation and low entrapment efficiency. Phospholipid nanogels have recently been recognized as prominent delivery systems to circumvent such obstacles and impart easier application. The current review provides an overview on different types of lecithin nanostructured gels, with particular emphasis on liposomal versus microemulsion gelled systems. Liposomal gels investigated encompassed classic liposomal hydrogel, modified liposomal gels (e.g. Transferosomal, Ethosomal, Pro-liposomal and Phytosomal gels), Microgel in liposomes (M-i-L) and Vesicular phospholipid gel (VPG). Microemulsion gelled systems encompassed Lecithin microemulsion-based organogels (LMBGs), Pluronic lecithin organogels (PLOs) and Lecithin-stabilized microemulsion-based hydrogels. All systems were reviewed regarding matrix composition, state of art, characterization and updated applications. Different classes of lecithin nanogels exhibited crucial impact on transdermal delivery regarding drug permeation, drug loading and stability aspects. Future perspectives of this theme issue are discussed based on current laboratory studies. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Transportation over long distance and thermal energy storage, coupling with energetic valuation processes from waste. State of art. Extended abstract

    International Nuclear Information System (INIS)

    Megret, O.; Bequet, L.; Manificat, A.; Weber, C.

    2011-12-01

    This study aims, on one hand, to realize a state of art about over long distance transport and heat energy storage and, on the other hand, to examine their coupling with waste valuation systems. After reminding the adequate context of development with those solutions and too showing the importance of the stake linked to the current work, we first expose the introductive elements in terms of storage and heat energy transport. The second chapter deals with the description of some materials, equipment and systems concerning heat storage energy. Afterward, the over long distance heat transport systems are detailed in the third chapter. In the fourth chapter, it is about waste valuation techniques and heat energy potentials users. The fifth chapter sums up the different techniques of storage and heat transport that are applicable to waste field according to the appropriate sector. Finally, the sixth chapter goes about 3 case-works in 3 fields: housing/commercial, industrial laundry and high temperature industry (steel industry). The purpose is to determine the implementation feasibility of the different techniques of storage and waste heat transport. (authors)

  2. MR imaging and T2 measurements in peripheral nerve repair with activation of Toll-like receptor 4 of neurotmesis

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Xiang; Zhang, Fang; Lu, Liejing; Li, Haojiang; Wen, Xuehua; Shen, Jun [Sun Yat-Sen University, Department of Radiology, Sun Yat-Sen Memorial Hospital, Guangzhou, Guangdong (China)

    2014-05-15

    To investigate the role of MR imaging in neurotmesis combined with surgical repair and Toll-like receptor 4 (TLR4) activation. Forty-eight rats received subepineurial microinjection of the TLR4 agonist lipopolysaccharide (LPS, n = 24) or phosphate buffered saline (PBS, n = 24) immediately after surgical repair of the transected sciatic nerve. Sequential fat-suppressed T2-weighted imaging and quantitative T2 measurements were obtained at 3, 7, 14 and 21 days after surgery, with histologic assessments performed at regular intervals. T2 relaxation times and histological quantification of the distal stumps were measured and compared. The distal stumps of transected nerves treated with LPS or PBS both showed persistent enlargement and hyperintense signal. T2 values of the distal stumps showed a rapid rise to peak level followed by a rapid decline pattern in nerves treated with LPS, while exhibiting a slow rise to peak value followed by a slow decline in nerves treated with PBS. Nerves treated with LPS exhibited more prominent macrophage recruitment, faster myelin debris clearance and more pronounced nerve regeneration. Nerves treated with TLR4 activation had a characteristic pattern of T2 value change over time. Longitudinal T2 measurements can be used to detect the enhanced repair effect associated with TLR4 activation in the surgical repair of neurotmesis. (orig.)

  3. Cardiac remodeling following percutaneous mitral valve repair - initial results assessed by cardiovascular magnetic resonance imaging

    DEFF Research Database (Denmark)

    Radunski, U K; Franzen, O; Barmeyer, A

    2014-01-01

    PURPOSE: Percutaneous mitral valve repair with the MitraClip device (Abbott Vascular, Redwood City, California, USA) is a novel therapeutic option in patients with mitral regurgitation. This study evaluated the feasibility of cardiac volume measurements by cardiovascular magnetic resonance imaging...... (CMR) to assess reverse myocardial remodeling in patients after MitraClip implantation. MATERIALS AND METHODS: 12 patients underwent CMR at baseline (BL) before and at 6 months follow-up (FU) after MitraClip implantation. Cine-CMR was performed in short- and long-axes for the assessment of left...... end-systolic (48 [42 - 80] vs. 51 [40 - 81] ml/m(2); p = 0.48), and LA (87 [55 - 124] vs. 92 [48 - 137] ml/m(2); p = 0.20) volume indices between BL and FU. CONCLUSION: CMR enables the assessment of cardiac volumes in patients after MitraClip implantation. Our CMR findings indicate that percutaneous...

  4. Is magnetic resonance imaging reliable in predicting clinical outcome after articular cartilage repair of the knee?

    NARCIS (Netherlands)

    de Windt, T.S.; Welsch, G.H.; Brittberg, M.; Vonk, L.A.; Marlovits, S.; Trattnig, S.; Saris, Daniël B.F.

    2013-01-01

    Background: While MRI can provide a detailed morphological evaluation after articular cartilage repair, its additional value in determining clinical outcome has yet to be determined. Purpose: To evaluate the correlation between MRI and clinical outcome after cartilage repair and to identify

  5. A secret-sharing-based method for authentication of grayscale document images via the use of the PNG image with a data repair capability.

    Science.gov (United States)

    Lee, Che-Wei; Tsai, Wen-Hsiang

    2012-01-01

    A new blind authentication method based on the secret sharing technique with a data repair capability for grayscale document images via the use of the Portable Network Graphics (PNG) image is proposed. An authentication signal is generated for each block of a grayscale document image, which, together with the binarized block content, is transformed into several shares using the Shamir secret sharing scheme. The involved parameters are carefully chosen so that as many shares as possible are generated and embedded into an alpha channel plane. The alpha channel plane is then combined with the original grayscale image to form a PNG image. During the embedding process, the computed share values are mapped into a range of alpha channel values near their maximum value of 255 to yield a transparent stego-image with a disguise effect. In the process of image authentication, an image block is marked as tampered if the authentication signal computed from the current block content does not match that extracted from the shares embedded in the alpha channel plane. Data repairing is then applied to each tampered block by a reverse Shamir scheme after collecting two shares from unmarked blocks. Measures for protecting the security of the data hidden in the alpha channel are also proposed. Good experimental results prove the effectiveness of the proposed method for real applications.

  6. Magnetic resonance imaging in the repair of ruptured Achilles tendons. Morphological difference in healing process between conservative and surgical treatment

    International Nuclear Information System (INIS)

    Nakano, Tetsuo; Tsuruta, Takao; Abe, Yasuyuki; Tani, Akifumi; Koga, Toshimitsu; Shimizu, Yasuhiro

    1996-01-01

    We observed the healing process of ruptured Achilles tendons in a series using magnetic resonance imaging. In six cases, tendons were repaired percutaneously with limited skin incisions. Seven cases were treated conservatively using unique functional braces. MR imaging revealed two different modes of conjoining. In the conservatively treated group, tendons inclined to conjoin in a dumbbell shape. In the surgically treated group, they inclined to conjoin in a spindle shape. The diameters of the ruptured part are wider in the spindle shape compared to the dumbbell shape at all stages. These findings suggest that surgical treatment is favorable for acquiring earlier strength. (author)

  7. An ImageJ-based algorithm for a semi-automated method for microscopic image enhancement and DNA repair foci counting

    International Nuclear Information System (INIS)

    Klokov, D.; Suppiah, R.

    2015-01-01

    Proper evaluation of the health risks of low-dose ionizing radiation exposure heavily relies on the ability to accurately measure very low levels of DNA damage in cells. One of the most sensitive methods for measuring DNA damage levels is the quantification of DNA repair foci that consist of macromolecular aggregates of DNA repair proteins, such as γH2AX and 53BP1, forming around individual DNA double-strand breaks. They can be quantified using immunofluorescence microscopy and are widely used as markers of DNA double-strand breaks. However this quantification, if performed manually, may be very tedious and prone to inter-individual bias. Low-dose radiation studies are especially sensitive to this potential bias due to a very low magnitude of the effects anticipated. Therefore, we designed and validated an algorithm for the semi-automated processing of microscopic images and quantification of DNA repair foci. The algorithm uses ImageJ, a freely available image analysis software that is customizable to individual cellular properties or experimental conditions. We validated the algorithm using immunolabeled 53BP1 and γH2AX in normal human fibroblast AG01522 cells under both normal and irradiated conditions. This method is easy to learn, can be used by nontrained personnel, and can help avoiding discrepancies in inter-laboratory comparison studies examining the effects of low-dose radiation. (author)

  8. An ImageJ-based algorithm for a semi-automated method for microscopic image enhancement and DNA repair foci counting

    Energy Technology Data Exchange (ETDEWEB)

    Klokov, D., E-mail: dmitry.klokov@cnl.ca [Canadian Nuclear Laboratories, Chalk River, Ontario (Canada); Suppiah, R. [Queen' s Univ., Dept. of Biomedical and Molecular Sciences, Kingston, Ontario (Canada)

    2015-06-15

    Proper evaluation of the health risks of low-dose ionizing radiation exposure heavily relies on the ability to accurately measure very low levels of DNA damage in cells. One of the most sensitive methods for measuring DNA damage levels is the quantification of DNA repair foci that consist of macromolecular aggregates of DNA repair proteins, such as γH2AX and 53BP1, forming around individual DNA double-strand breaks. They can be quantified using immunofluorescence microscopy and are widely used as markers of DNA double-strand breaks. However this quantification, if performed manually, may be very tedious and prone to inter-individual bias. Low-dose radiation studies are especially sensitive to this potential bias due to a very low magnitude of the effects anticipated. Therefore, we designed and validated an algorithm for the semi-automated processing of microscopic images and quantification of DNA repair foci. The algorithm uses ImageJ, a freely available image analysis software that is customizable to individual cellular properties or experimental conditions. We validated the algorithm using immunolabeled 53BP1 and γH2AX in normal human fibroblast AG01522 cells under both normal and irradiated conditions. This method is easy to learn, can be used by nontrained personnel, and can help avoiding discrepancies in inter-laboratory comparison studies examining the effects of low-dose radiation. (author)

  9. Pros and Cons of 3D Image Fusion in Endovascular Aortic Repair: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Goudeketting, Seline R; Heinen, Stefan G H; Ünlü, Çağdaş; van den Heuvel, Daniel A F; de Vries, Jean-Paul P M; van Strijen, Marco J; Sailer, Anna M

    2017-08-01

    To systematically review and meta-analyze the added value of 3-dimensional (3D) image fusion technology in endovascular aortic repair for its potential to reduce contrast media volume, radiation dose, procedure time, and fluoroscopy time. Electronic databases were systematically searched for studies published between January 2010 and March 2016 that included a control group describing 3D fusion imaging in endovascular aortic procedures. Two independent reviewers assessed the methodological quality of the included studies and extracted data on iodinated contrast volume, radiation dose, procedure time, and fluoroscopy time. The contrast use for standard and complex endovascular aortic repairs (fenestrated, branched, and chimney) were pooled using a random-effects model; outcomes are reported as the mean difference with 95% confidence intervals (CIs). Seven studies, 5 retrospective and 2 prospective, involving 921 patients were selected for analysis. The methodological quality of the studies was moderate (median 17, range 15-18). The use of fusion imaging led to an estimated mean reduction in iodinated contrast of 40.1 mL (95% CI 16.4 to 63.7, p=0.002) for standard procedures and a mean 70.7 mL (95% CI 44.8 to 96.6, p<0.001) for complex repairs. Secondary outcome measures were not pooled because of potential bias in nonrandomized data, but radiation doses, procedure times, and fluoroscopy times were lower, although not always significantly, in the fusion group in 6 of the 7 studies. Compared with the control group, 3D fusion imaging is associated with a significant reduction in the volume of contrast employed for standard and complex endovascular aortic procedures, which can be particularly important in patients with renal failure. Radiation doses, procedure times, and fluoroscopy times were reduced when 3D fusion was used.

  10. The imaging assessment and specific endograft design for the endovascular repair of ascending aortic dissection

    Directory of Open Access Journals (Sweden)

    Zhang Y

    2016-07-01

    (10.4%, 22 (45.9%, 13 (27.1%, six (12.5%, and two (4.2% patients, respectively. Conclusion: In this selected number of Chinese patients, the suitability of endovascular repair has been demonstrated based on the CT imaging. Shorter, larger, and bare spring-free conical endografts were preferred in the ascending aortic pathology. Keywords: type A dissection, endovascular, endograft, design

  11. Segmentation, surface rendering, and surface simplification of 3-D skull images for the repair of a large skull defect

    Science.gov (United States)

    Wan, Weibing; Shi, Pengfei; Li, Shuguang

    2009-10-01

    Given the potential demonstrated by research into bone-tissue engineering, the use of medical image data for the rapid prototyping (RP) of scaffolds is a subject worthy of research. Computer-aided design and manufacture and medical imaging have created new possibilities for RP. Accurate and efficient design and fabrication of anatomic models is critical to these applications. We explore the application of RP computational methods to the repair of a pediatric skull defect. The focus of this study is the segmentation of the defect region seen in computerized tomography (CT) slice images of this patient's skull and the three-dimensional (3-D) surface rendering of the patient's CT-scan data. We see if our segmentation and surface rendering software can improve the generation of an implant model to fill a skull defect.

  12. Multimodality Imaging Approach towards Primary Aortic Sarcomas Arising after Endovascular Abdominal Aortic Aneurysm Repair: Case Series Report

    Energy Technology Data Exchange (ETDEWEB)

    Kamran, Mudassar, E-mail: kamranm@mir.wustl.edu; Fowler, Kathryn J., E-mail: fowlerk@mir.wustl.edu; Mellnick, Vincent M., E-mail: mellnickv@mir.wustl.edu [Washington University School of Medicine, Mallinckrodt Institute of Radiology (United States); Sicard, Gregorio A., E-mail: sicard@wudosis.wustl.edu [Washington University School of Medicine, Department of Surgery (United States); Narra, Vamsi R., E-mail: narrav@mir.wustl.edu [Washington University School of Medicine, Mallinckrodt Institute of Radiology (United States)

    2016-06-15

    Primary aortic neoplasms are rare. Aortic sarcoma arising after endovascular aneurysm repair (EVAR) is a scarce subset of primary aortic malignancies, reports of which are infrequent in the published literature. The diagnosis of aortic sarcoma is challenging due to its non-specific clinical presentation, and the prognosis is poor due to delayed diagnosis, rapid proliferation, and propensity for metastasis. Post-EVAR, aortic sarcomas may mimic other more common aortic processes on surveillance imaging. Radiologists are rarely knowledgeable about this rare entity for which multimodality imaging and awareness are invaluable in early diagnosis. A series of three pathologically confirmed cases are presented to display the multimodality imaging features and clinical presentations of aortic sarcoma arising after EVAR.

  13. Repair of distal biceps brachii tendon assessed with 3-T magnetic resonance imaging and correlation with functional outcome

    Energy Technology Data Exchange (ETDEWEB)

    Alemann, Guillaume; Dietsch, Emmanuel [University Hospital of Besancon, Department of Musculoskeletal Imaging, Besancon (France); Gallinet, David; Obert, Laurent [University Hospital of Besancon, Department of Orthopedic Surgery, Besancon (France); Kastler, Bruno; Aubry, Sebastien [University Hospital of Besancon, Department of Musculoskeletal Imaging, Besancon (France); Franche Comte University, I4S Laboratory-EA 4268-IFR 133, Besancon (France)

    2015-05-01

    Objectives were to study the MRI appearance of the repaired distal biceps tendon (DBT), anatomically reinserted, and to search for a correlation between tendon measurements and functional results. Twenty-five patients (mean age, 49 ± 4.9 years old) who benefited from 3-T MRI follow-up of the elbow after surgical reinsertion of the DBT were retrospectively included and compared to a control group (n = 25; mean age, 48 ± 10 years old). MRI was performed during the month of clinical follow-up and on average 22 months after surgery. Delayed complications (secondary avulsion, new rupture), intratendinous osteoma, tendinous signal on T1-weighted (T1{sub w}) and fat-suppressed proton density-weighted (FS-PD{sub w}) images as well as DBT measurements were recorded. The maximum isometric elbow flexion strength (MEFS) and range of motion of the elbow were assessed. Repaired DBT demonstrated a heterogeneous but normally fibrillar structure. Its low T1{sub w} signal was less pronounced than that of normal tendons, and the FS-PD{sub W} image signal was similar to that of T1{sub w} images. MRI detected seven osteomas (Se = 53 % vs. plain radiography), one textiloma and one secondary avulsion. Repaired DBT measurements were significantly correlated with MEFS (dominant arm R2: 0.38; nondominant arm R2: 0.54); this correlation involved the insertion surface (Δ = -75.7 mm{sup 2}, p = 0.046), transverse diameter (Δ = -2.6 mm, p = 0.018), anteroposterior diameter at the level of the radial head (Δ = -3.9 mm, p = 0.001) and DBT cross-sectional area (Δ = -50.2 mm{sup 2}, p = 0.003). The quality of functional outcome after anatomical elbow rehabilitation of DBT correlates with the extent of tendinous hypertrophy during the healing process. (orig.)

  14. Repair of distal biceps brachii tendon assessed with 3-T magnetic resonance imaging and correlation with functional outcome

    International Nuclear Information System (INIS)

    Alemann, Guillaume; Dietsch, Emmanuel; Gallinet, David; Obert, Laurent; Kastler, Bruno; Aubry, Sebastien

    2015-01-01

    Objectives were to study the MRI appearance of the repaired distal biceps tendon (DBT), anatomically reinserted, and to search for a correlation between tendon measurements and functional results. Twenty-five patients (mean age, 49 ± 4.9 years old) who benefited from 3-T MRI follow-up of the elbow after surgical reinsertion of the DBT were retrospectively included and compared to a control group (n = 25; mean age, 48 ± 10 years old). MRI was performed during the month of clinical follow-up and on average 22 months after surgery. Delayed complications (secondary avulsion, new rupture), intratendinous osteoma, tendinous signal on T1-weighted (T1 w ) and fat-suppressed proton density-weighted (FS-PD w ) images as well as DBT measurements were recorded. The maximum isometric elbow flexion strength (MEFS) and range of motion of the elbow were assessed. Repaired DBT demonstrated a heterogeneous but normally fibrillar structure. Its low T1 w signal was less pronounced than that of normal tendons, and the FS-PD W image signal was similar to that of T1 w images. MRI detected seven osteomas (Se = 53 % vs. plain radiography), one textiloma and one secondary avulsion. Repaired DBT measurements were significantly correlated with MEFS (dominant arm R2: 0.38; nondominant arm R2: 0.54); this correlation involved the insertion surface (Δ = -75.7 mm 2 , p = 0.046), transverse diameter (Δ = -2.6 mm, p = 0.018), anteroposterior diameter at the level of the radial head (Δ = -3.9 mm, p = 0.001) and DBT cross-sectional area (Δ = -50.2 mm 2 , p = 0.003). The quality of functional outcome after anatomical elbow rehabilitation of DBT correlates with the extent of tendinous hypertrophy during the healing process. (orig.)

  15. MR imaging after rotator cuff repair: full-thickness defects and bursitis-like subacromial abnormalities in asymptomatic subjects

    International Nuclear Information System (INIS)

    Zanetti, M.; Hodler, J.; Jost, B.; Gerber, C.

    2000-01-01

    Objective. To determine the prevalence and extent of residual defects or retears and bursitis-like subacromial abnormalities on MR images after rotator cuff repair in asymptomatic subjects, and to define the clinical relevance of these findings.Design and patients. Fourteen completely asymptomatic patients and 32 patients with residual symptoms were investigated 27-53 months (mean 39 months) after open transosseous reinsertion of the rotator cuff. Coronal T2-weighted turbo spin-echo and turbo STIR or T2-weighted fat-suppressed MR images were obtained. The prevalence and extent of residual defects or retears of the rotator cuff and bursitis-like subacromial abnormalities were determined.Results. Residual defects or retears were detected in three (21%) and bursitis-like abnormalities in 14 (100%) of the 14 asymptomatic patients. Fifteen (47%) residual defects or retears and 31 (97%) bursitis-like abnormalities were diagnosed in the 32 patients with residual symptoms. The size of the residual defects/retears was significantly smaller in the asymptomatic group (mean 8 mm, range 6-11 mm) than in the symptomatic group (mean 32 mm, range 7-50 mm) (t-test, P=0.001). The extent of the bursitis-like subacromial abnormalities did not significantly differ (t-test, P>0.05) between asymptomatic (mean 28 x 3 mm) and symptomatic patients (mean 32 x 3 mm).Conclusion. Small residual defects or retears (<1 cm) of the rotator cuff are not necessarily associated with clinical symptoms. Subacromial bursitis-like MR abnormalities are almost always seen after rotator cuff repair even in patients without residual complaints. They may persist for several years after rotator cuff repair and appear to be clinically irrelevant. (orig.)

  16. MR imaging after rotator cuff repair: full-thickness defects and bursitis-like subacromial abnormalities in asymptomatic subjects

    Energy Technology Data Exchange (ETDEWEB)

    Zanetti, M.; Hodler, J. [Dept. of Radiology, University Hospital Balgrist, Zurich (Switzerland); Jost, B.; Gerber, C. [Dept. of Orthopedic Surgery, University Hospital Balgrist, Zurich (Switzerland)

    2000-06-01

    Objective. To determine the prevalence and extent of residual defects or retears and bursitis-like subacromial abnormalities on MR images after rotator cuff repair in asymptomatic subjects, and to define the clinical relevance of these findings.Design and patients. Fourteen completely asymptomatic patients and 32 patients with residual symptoms were investigated 27-53 months (mean 39 months) after open transosseous reinsertion of the rotator cuff. Coronal T2-weighted turbo spin-echo and turbo STIR or T2-weighted fat-suppressed MR images were obtained. The prevalence and extent of residual defects or retears of the rotator cuff and bursitis-like subacromial abnormalities were determined.Results. Residual defects or retears were detected in three (21%) and bursitis-like abnormalities in 14 (100%) of the 14 asymptomatic patients. Fifteen (47%) residual defects or retears and 31 (97%) bursitis-like abnormalities were diagnosed in the 32 patients with residual symptoms. The size of the residual defects/retears was significantly smaller in the asymptomatic group (mean 8 mm, range 6-11 mm) than in the symptomatic group (mean 32 mm, range 7-50 mm) (t-test, P=0.001). The extent of the bursitis-like subacromial abnormalities did not significantly differ (t-test, P>0.05) between asymptomatic (mean 28 x 3 mm) and symptomatic patients (mean 32 x 3 mm).Conclusion. Small residual defects or retears (<1 cm) of the rotator cuff are not necessarily associated with clinical symptoms. Subacromial bursitis-like MR abnormalities are almost always seen after rotator cuff repair even in patients without residual complaints. They may persist for several years after rotator cuff repair and appear to be clinically irrelevant. (orig.)

  17. Using radionuclide imaging for monitoring repairment of bone defect with tissue-engineered bone graft in rabbits

    International Nuclear Information System (INIS)

    Xia Changsuo; Ye Fagang; Zou Yunwen; Ji Shixiang; Wang Dengchun

    2004-01-01

    Objective: To observe the effect of tissue-engineered bone grafts in repairing bone defect in rabbits, and assess the value of radionuclide for monitoring the therapeutic effect of this approach. Methods: Bilateral radial defects of 15 mm in length in 24 rabbits were made. The tissue-engineered bone grafts (composite graft) contained bone marrow stromal cells (BMSCs) of rabbits and calcium phosphate cement (CPC) were grafted in left side defects, CPC only grafts (artificial bone graft) in right defects. After the operation, radionuclide was used to monitor the therapeutic effects at 4, 8 and 12 weeks. Results: 99 Tc m -methylene diphosphonic acid (MDP) radionuclide bone imaging indicated that there was more radionuclide accumulation in grafting region of composite than that of CPC. There was significant difference between 99 Tc m -MDP uptake of the region of interest (ROI) and scintillant counts of composite bone and the artificial bone (P<0.01). Conclusion: Tissue-engineered bone grafts is eligible for repairing radial bone defects, and radionuclide imaging may accurately monitor the revascularization and bone regeneration after the bone graft implantation. (authors)

  18. Algorithm for repairing the damaged images of grain structures obtained from the cellular automata and measurement of grain size

    Science.gov (United States)

    Ramírez-López, A.; Romero-Romo, M. A.; Muñoz-Negron, D.; López-Ramírez, S.; Escarela-Pérez, R.; Duran-Valencia, C.

    2012-10-01

    Computational models are developed to create grain structures using mathematical algorithms based on the chaos theory such as cellular automaton, geometrical models, fractals, and stochastic methods. Because of the chaotic nature of grain structures, some of the most popular routines are based on the Monte Carlo method, statistical distributions, and random walk methods, which can be easily programmed and included in nested loops. Nevertheless, grain structures are not well defined as the results of computational errors and numerical inconsistencies on mathematical methods. Due to the finite definition of numbers or the numerical restrictions during the simulation of solidification, damaged images appear on the screen. These images must be repaired to obtain a good measurement of grain geometrical properties. Some mathematical algorithms were developed to repair, measure, and characterize grain structures obtained from cellular automata in the present work. An appropriate measurement of grain size and the corrected identification of interfaces and length are very important topics in materials science because they are the representation and validation of mathematical models with real samples. As a result, the developed algorithms are tested and proved to be appropriate and efficient to eliminate the errors and characterize the grain structures.

  19. Variance of [sup 99m]Tc-MDP bone imaging among the repairing process after experimental femoral head necrosis

    Energy Technology Data Exchange (ETDEWEB)

    Shibiao, Sang; Yimin, Jiang; Jinxi, Wang [Suzhou Medical Coll., Suzhou, JS (China). First Affiliated Hospital

    1993-05-01

    Six of 26 adult mongrel dogs were used as controls. Avascular necrosis of the left femoral head was induced by freezing method with liquid nitrogen and the right side being used as a self-control. The 20 dogs were divided into four groups, 5 dogs each which was sacrificed successively at 1/2, 2,2 and 6 months after operation. All of the femoral heads were studied by radionuclide bone imaging, radiological, histological and biochemical examinations. The results were as follows: [sup 99m]Tc-MDP bone imaging showed a decreased uptake at the early stage, and was gradually increased later, and reached its peak values at precollape stage at four months. Hypermetabolism state was still maintained at collapsed stage. Above changes was in coincidence with the bone imaging. As for the repairing process after necrosis, the hypermetabolic reaction in bone imaging of the femoral head correlates well with the proliferation of vessels and bone marrow cells and also the activity of tissue collagenase. Therefore, a poor bony reconstruction in the weight-bearing portion could be an important cause for late segmental collapse.

  20. MR imaging of canine osteoarthritis shows sustained hypertrophic repair of articular cartilage

    International Nuclear Information System (INIS)

    Braunstein, E.M.; Albrecht, M.; Brandt, K.D.

    1989-01-01

    This paper reports MR imaging used to evaluate cartilage abnormalities in three dogs in which the anterior cruciate ligament (ACL) of one hind limb had been transected to produce osteoarthritis. In this model changes mirror those in human osteoarthritis, but they are not progressive after a few months. The authors performed serial plain radiography and MR imaging of the osteoarthritic knee and control knee 3 years after ACL transection. Coronal T1- weighted images and sagittal multiecho and field echo summed images were obtained. Radiographs showed osteophytes, geodes, and subchondral sclerosis of the operated knees, with no progression between 2 and 3 years. Contralateral knees were normal. On MR images in each case there was indistinctness and thickening of articular cartilage in the abnormal knee compared with the contralateral knee

  1. Maximum Diameter Measurements of Aortic Aneurysms on Axial CT Images After Endovascular Aneurysm Repair: Sufficient for Follow-up?

    International Nuclear Information System (INIS)

    Baumueller, Stephan; Nguyen, Thi Dan Linh; Goetti, Robert Paul; Lachat, Mario; Seifert, Burkhardt; Pfammatter, Thomas; Frauenfelder, Thomas

    2011-01-01

    Purpose: To assess the accuracy of maximum diameter measurements of aortic aneurysms after endovascular aneurysm repair (EVAR) on axial computed tomographic (CT) images in comparison to maximum diameter measurements perpendicular to the intravascular centerline for follow-up by using three-dimensional (3D) volume measurements as the reference standard. Materials and Methods: Forty-nine consecutive patients (73 ± 7.5 years, range 51–88 years), who underwent EVAR of an infrarenal aortic aneurysm were retrospectively included. Two blinded readers twice independently measured the maximum aneurysm diameter on axial CT images performed at discharge, and at 1 and 2 years after intervention. The maximum diameter perpendicular to the centerline was automatically measured. Volumes of the aortic aneurysms were calculated by dedicated semiautomated 3D segmentation software (3surgery, 3mensio, the Netherlands). Changes in diameter of 0.5 cm and in volume of 10% were considered clinically significant. Intra- and interobserver agreements were calculated by intraclass correlations (ICC) in a random effects analysis of variance. The two unidimensional measurement methods were correlated to the reference standard. Results: Intra- and interobserver agreements for maximum aneurysm diameter measurements were excellent (ICC = 0.98 and ICC = 0.96, respectively). There was an excellent correlation between maximum aneurysm diameters measured on axial CT images and 3D volume measurements (r = 0.93, P < 0.001) as well as between maximum diameter measurements perpendicular to the centerline and 3D volume measurements (r = 0.93, P < 0.001). Conclusion: Measurements of maximum aneurysm diameters on axial CT images are an accurate, reliable, and robust method for follow-up after EVAR and can be used in daily routine.

  2. Cleft lip and palate repair

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/002979.htm Cleft lip and palate repair To use the sharing features on this ... Cheiloplasty; Cleft rhinoplasty; Palatoplasty; Tip rhinoplasty Patient Instructions Cleft lip and palate repair - discharge Images Cleft lip repair - series References ...

  3. Matrix-based autologous chondrocyte implantation for cartilage repair with Hyalograft(R)C: Two-year follow-up by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Trattnig, S.; Pinker, K.; Krestan, C.; Plank, C.; Millington, S.; Marlovits, S.

    2006-01-01

    Objective: Monitoring of articular cartilage repair after matrix-associated autologous chondrocyte implantation with Hyalograft ( R)C by a new grading system based on non-invasive high-resolution magnetic resonance imaging. Patients and methods: In 23 patients, postoperative magnetic resonance imaging (MRI) was performed between 76 and 120 weeks. In nine of these patients, five MRI examinations were performed at 4, 12, 24, 52 and 104 weeks after Hyalograft ( R)C implant. The repair tissue was described with separate variables: degree of defect repair in width and length, signal intensity of the repair tissue and status of the subchondral bone. For these variables a grading system with point scale evaluation was applied. Results: A complete filling of the defect by repair tissue was found in 15 patients. A moderate hypertrophy of the repair tissue was found in two patients. An underfilling of the defect by repair tissue was observed in four patients. In one patient, a partial detachment of the implant with associated subchondral cyst and edema was seen, and in one patient, a complete detachment of the graft was observed. The filling of the defect parallel to cartilage surface (integration) was complete in 18 cases. A split-like incomplete integration was present in one patient. Incomplete integration was found in four patients. The signal intensity of the implant on FSE and on 3D-GRE+FS was isointense compared to native normal cartilage in all cases after 12 months. The subchondral bone was normal in 14 patients. An edema-like signal alteration was found in three cases. In six patients, a non-edema abnormality of the subchondral bone (granulation tissue, cysts or sclerosis) was present. On follow-up exams performed in nine patients at the same postoperative intervals dynamic processes such as filling of partial defects, vanishing of hypertrophies and change of signal intensity of implant to isointensity with native articular cartilage were observed. A comparison

  4. Towards image-guided atrial septal defect repair: an ex vivo analysis

    Science.gov (United States)

    Kwartowitz, David M.; Mefleh, Fuad N.; Baker, George H.

    2012-02-01

    The use of medical images in the operating room for navigation and planning is well established in many clinical disciplines. In cardiology, the use of fluoroscopy for the placement of catheters within the heart has become the standard of care. While fluoroscopy provides a live video sequence with the current location, it poses risks the patient and clinician through exposure to radiation. Radiation dose is cumulative and thus children are at even greater risk from exposure. To reduce the use of radiation, and improve surgical technique we have begun development of an image-guided navigation system, which can deliver therapeutic devices via catheter. In this work we have demonstrated the intrinsic properties of our imaging system, which have led to the development of a phantom emulating a childs heart with an ASD. Further investigation into the use of this information, in a series of mock clinical experiments, will be performed to design procedures for inserting devices into the heart while minimizing fluoroscopy use.

  5. DNA repair

    International Nuclear Information System (INIS)

    Setlow, R.

    1978-01-01

    Some topics discussed are as follows: difficulty in extrapolating data from E. coli to mammalian systems; mutations caused by UV-induced changes in DNA; mutants deficient in excision repair; other postreplication mechanisms; kinds of excision repair systems; detection of repair by biochemical or biophysical means; human mutants deficient in repair; mutagenic effects of UV on XP cells; and detection of UV-repair defects among XP individuals

  6. Evaluation of breast cancer through mammographies and image digital processing; Avaliacao do cancer de mama atraves de mamografias e processamento digital de imagens

    Energy Technology Data Exchange (ETDEWEB)

    Crestana, Rita H.S.

    1996-12-31

    The state of art of image processing has provided important advances to many scientific investigation areas particularly to medical own. This work exploits the potentiality of using image processing techniques for analyzing breast phantoms and mammographies. 36 refs., 62 figs.

  7. Biomechanical and magnetic resonance imaging evaluation of a single- and double-row rotator cuff repair in an in vivo sheep model.

    Science.gov (United States)

    Baums, Mike H; Spahn, Gunter; Buchhorn, Gottfried H; Schultz, Wolfgang; Hofmann, Lars; Klinger, Hans-Michael

    2012-06-01

    To investigate the biomechanical and magnetic resonance imaging (MRI)-derived morphologic changes between single- and double-row rotator cuff repair at different time points after fixation. Eighteen mature female sheep were randomly assigned to either a single-row treatment group using arthroscopic Mason-Allen stitches or a double-row treatment group using a combination of arthroscopic Mason-Allen and mattress stitches. Each group was analyzed at 1 of 3 survival points (6 weeks, 12 weeks, and 26 weeks). We evaluated the integrity of the cuff repair using MRI and biomechanical properties using a mechanical testing machine. The mean load to failure was significantly higher in the double-row group compared with the single-row group at 6 and 12 weeks (P = .018 and P = .002, respectively). At 26 weeks, the differences were not statistically significant (P = .080). However, the double-row group achieved a mean load to failure similar to that of a healthy infraspinatus tendon, whereas the single-row group reached only 70% of the load of a healthy infraspinatus tendon. No significant morphologic differences were observed based on the MRI results. This study confirms that in an acute repair model, double-row repair may enhance the speed of mechanical recovery of the tendon-bone complex when compared with single-row repair in the early postoperative period. Double-row rotator cuff repair enables higher mechanical strength that is especially sustained during the early recovery period and may therefore improve clinical outcome. Crown Copyright © 2012. Published by Elsevier Inc. All rights reserved.

  8. Longitudinal Long-term Magnetic Resonance Imaging and Clinical Follow-up After Single-Row Arthroscopic Rotator Cuff Repair: Clinical Superiority of Structural Tendon Integrity.

    Science.gov (United States)

    Heuberer, Philipp R; Smolen, Daniel; Pauzenberger, Leo; Plachel, Fabian; Salem, Sylvia; Laky, Brenda; Kriegleder, Bernhard; Anderl, Werner

    2017-05-01

    The number of arthroscopic rotator cuff surgeries is consistently increasing. Although generally considered successful, the reported number of retears after rotator cuff repair is substantial. Short-term clinical outcomes are reported to be rarely impaired by tendon retears, whereas to our knowledge, there is no study documenting long-term clinical outcomes and tendon integrity after arthroscopic rotator cuff repair. To investigate longitudinal long-term repair integrity and clinical outcomes after arthroscopic rotator cuff reconstruction. Case series; Level of evidence, 4. Thirty patients who underwent arthroscopic rotator cuff repair with suture anchors for a full-tendon full-thickness tear of the supraspinatus or a partial-tendon full-thickness tear of the infraspinatus were included. Two and 10 years after initial arthroscopic surgery, tendon integrity was analyzed using magnetic resonance imaging (MRI). The University of California, Los Angeles (UCLA) score and Constant score as well as subjective questions regarding satisfaction with the procedure and return to normal activity were used to evaluate short- and long-term outcomes. At the early MRI follow-up, 42% of patients showed a full-thickness rerupture, while 25% had a partial rerupture, and 33% of tendons remained intact. The 10-year MRI follow-up (129 ± 11 months) showed 50% with a total rerupture, while the other half of the tendons were partially reruptured (25%) or intact (25%). The UCLA and Constant scores significantly improved from preoperatively (UCLA total: 50.6% ± 20.2%; Constant total: 44.7 ± 10.5 points) to 2 years (UCLA total: 91.4% ± 16.0% [ P rotator cuff repair showed good clinical long-term results despite a high rate of retears. Nonetheless, intact tendons provided significantly superior clinical long-term outcomes, making the improvement of tendon healing and repair integrity important goals of future research efforts.

  9. Detection of Repair of the Zone of Calcified Cartilage with Osteoarthritis through Mesenchymal Stem Cells by Ultrashort Echo Time Magnetic Resonance Imaging.

    Science.gov (United States)

    Zhou, Quan; Li, Shao-Lin; Ma, Ya-Jun; de Tal, Vicki; Li, Wei; Zhao, Ying-Hua

    2018-05-05

    Currently, magnetic resonance imaging (MRI) is the most commonly used imaging modality for observing the growth and development of mesenchymal stem cells (MSCs) after in vivo transplantation to treat osteoarthritis (OA). However, it is a challenge to accurately monitor the treatment effects of MSCs in the zone of calcified cartilage (ZCC) with OA. This is especially true in the physiological and biochemical views that are not accurately detected by MRI contrast agents. In contrast, ultrashort time echo (UTE) MRI has been shown to be sensitive to the presence of the ZCC, creating the potential for more effectively observing the repair of the ZCC in OA by MSCs. A special focus is given to the outlook of the use of UTE MRI to detect repair of the ZCC with OA through MSCs. The limitations of the current techniques for clinical applications and future directions are also discussed. Using the combined keywords: "osteoarthritis", "mesenchymal stem cells", "calcified cartilage", and "magnetic resonance imaging", the PubMed/MEDLINE literature search was conducted up to June 1, 2017. A total of 132 published articles were initially identified citations. Of the 132 articles, 48 articles were selected after further detailed review. This study referred to all the important English literature in full. In contrast, UTE MRI has been shown to be sensitive to the presence of the ZCC, creating the potential for more effectively observing the repair of the ZCC in OA by MSCs. The current studies showed that the ZCC could be described in terms of its histomorphology and biochemistry by UTE MRI. We prospected that UTE MRI has been shown the potential for more effectively observing the repair of the ZCC in OA by MSCs in vivo.

  10. Imaging of the rabbit supraspinatus enthesis at 7 Tesla: a 4-week time course after repair surgery and effect of channeling.

    Science.gov (United States)

    Trudel, Guy; Melkus, Gerd; Cron, Greg O; Louati, Hakim; Sheikh, Adnan; Larson, Peder E Z; Schweitzer, Mark; Lapner, Peter; Uhthoff, Hans K; Laneuville, Odette

    2017-08-01

    To image the supraspinatus enthesis reformation of rabbit shoulders by magnetic resonance at 7 Tesla (T) using T2 mapping after surgical repair and to assess the effects of channeling aimed at enhancing enthesis reformation. In 112 rabbits, the distal supraspinatus (SSP) tendon was unilaterally detached and reattached after 1 week. At the first surgery, channeling was performed at the footprint in 64 rabbits. At the second surgery, the SSP tendon of all rabbits was re-attached to the greater tuberosity. The shoulders were harvested at 0, 1, 2, or 4 weeks after the repair surgery and were imaged at 7T. Quantitative T2 mapping was performed using multi slice two-dimensional multi-echo spin-echo sequence with fat saturation. Enthesis regions of interests were drawn on three slices at the footprint to measure T2 relaxation times. Tendon repair (F (2, 218)  = 44; P < 2.2e-16) and postoperative duration (F (3, 218)  = 4.8; P = 0.006) both affected significantly the T2 values while channeling had no significant effect. For the time effect, the only pair with a statistical difference was the 0-week and 4-week for the channeling groups (P = 0.023). Enthesis reformation early after surgical repair of the SSP distal tendon was characterized by increasing T2 values. 2 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;46:461-467. © 2017 International Society for Magnetic Resonance in Medicine.

  11. Prenatal MR imaging of congenital diaphragmatic hernias: association of MR fetal lung volume with the need for postnatal prosthetic patch repair

    Energy Technology Data Exchange (ETDEWEB)

    Hagelstein, Claudia; Weidner, Meike; Schoenberg, Stefan O.; Buesing, Karen A.; Neff, K.W. [University of Heidelberg, Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Mannheim (Germany); Zahn, Katrin [University of Heidelberg, Department of Pediatric Surgery, University Medical Center Mannheim, Mannheim (Germany); Weiss, Christel [University of Heidelberg, Department of Medical Statistics and Biomathematics, University Medical Center Mannheim, Mannheim (Germany); Schaible, Thomas [University of Heidelberg, Department of Pediatrics, University Medical Center Mannheim, Mannheim (Germany)

    2015-01-15

    To assess whether the need for postnatal prosthetic patch repair of the diaphragmatic defect in neonates with a congenital diaphragmatic hernia (CDH) is associated with the antenatal measured observed-to-expected magnetic resonance fetal lung volume (o/e MR-FLV). The o/e MR-FLV was calculated in 247 fetuses with isolated CDH. Logistic regression analysis was used to assess the prognostic value of the individual o/e MR-FLV for association with the need for postnatal patch repair. Seventy-seven percent (77 %) of patients with a CDH (190/247) required prosthetic patch repair and the defect was closed primarily in 23 % (57/247). Patients requiring a patch had a significantly lower o/e MR-FLV (27.7 ± 10.2 %) than patients with primary repair (40.8 ± 13.8 %, p < 0.001, AUC = 0.786). With an o/e MR-FLV of 20 %, 92 % of the patients required patch repair, compared to only 24 % with an o/e MR-FLV of 60 %. The need for a prosthetic patch was further influenced by the fetal liver position (herniation/no herniation) as determined by magnetic resonance imaging (MRI; p < 0.001). Fetal liver position, in addition to the o/e MR-FLV, improves prognostic accuracy (AUC = 0.827). Logistic regression analysis based on the o/e MR-FLV is useful for prenatal estimation of the prosthetic patch requirement in patients with a CDH. In addition to the o/e MR-FLV, the position of the liver as determined by fetal MRI helps improve prognostic accuracy. (orig.)

  12. Examination of the skin barrier repair/wound healing process using a living skin equivalent model and matrix-assisted laser desorption-ionization-mass spectrometry imaging.

    Science.gov (United States)

    Lewis, E E L; Barrett, M R T; Freeman-Parry, L; Bojar, R A; Clench, M R

    2018-04-01

    Examination of the skin barrier repair/wound healing process using a living skin equivalent (LSE) model and matrix-assisted laser desorption/ionization-mass spectrometry imaging (MALDI-MSI) to identify lipids directly involved as potential biomarkers. These biomarkers may be used to determine whether an in vivo wound is going to heal for example if infected. An in vitro LSE model was wounded with a scalpel blade and assessed at day 4 post-wounding by histology and MALDI-MSI. Samples were sectioned at wound site and were either formalin-fixed paraffin-embedded (FFPE) for histology or snapped frozen (FF) for MSI analysis. The combination of using an in vitro wounded skin model with MSI allowed the identification of lipids involved in the skin barrier repair/wound healing process. The technique was able to highlight lipids directly in the wound site and distinguish differences in lipid distribution between the epidermis and wound site. This novel method of coupling an in vitro LSE with MSI allowed in-depth molecular analysis of the skin barrier repair/wound healing process. The technique allowed the identification of lipids directly involved in the skin barrier repair/wound healing process, indicating these biomarkers may be potentially be used within the clinic. These biomarkers will help to determine, which stage of the skin barrier repair/wound healing process the wound is in to provide the best treatment. © 2018 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  13. Evaluation of bone repair in the femur of rats submitted to laser therapy in different wavelengths: An image segmentation method of analysis

    Science.gov (United States)

    Queiroga, A. S.; Sousa, F. B.; Araújo, J. M. S.; Santos, S. D.; Sousa, C. D'f. S.; Quintans, T. C.; Almeida, T. P.; Nonaka, C. F. W.; Batista, L. V.; Limeira Junior, F. A.

    2008-09-01

    The aim of this study was to histologically assess the effect of laser therapy (LILT, 660 and 780 nm) on the repair of standardized bone defects on the femur of Wistar albinus rats. The sample was composed of 12 Wistar albinus young adult rats of both genders. Three randomized groups were studied: group I (control, n = 4), group II (LILT, 660 nm, n = 4), and group III (LILT, 780 nm, n = 4). Samples were prepared using a bone defect on the left-side femur surface of the animals, with a total dimension of approximately 3 mm3. Groups II and III were irradiated every 48 h from the second application, where the first dose was given immediately after surgery and the second application came 24 h after surgery. The irradiations were applied transcutaneously at four points around the wound for 14 days. At each point, a dose of 50 J/cm2 (2 J) was given ( s ˜ 0.04 cm2, 40 mW) and the total dose per session was 200 J/cm2 (8 J). The sacrifices were made 15 days after surgery and the specimens were routinely processed to wax, serially cut, stained with an H&E stain, and analyzed under light microscopy. The images were submitted to morphometric analysis using the image segmentation method using the K-means algorithm. The data obtained through the morphometric analysis were submitted to statistical analysis using the Tukey test. The results showed that the group treated with laser therapy in the infrared spectrum resulted in an increase in the repair of bone defects when compared with the group treated with the laser in the red spectrum and control group, which, in turn, had a very similar pattern of repair. A statistical significance ( p spectrum produced a positive biomodulation effect on the repair of bone defects in the femur of rats.

  14. Meningocele repair - series (image)

    Science.gov (United States)

    ... containing a portion of the spinal cord membrane (meninges), spinal fluid, and a portion of spinal cord ... The spinal cord is covered with the membranes (meninges) and the skin is closed over the protruding ...

  15. Quantitative pulmonary perfusion imaging at 3.0 T of 2-year-old children after congenital diaphragmatic hernia repair: initial results

    International Nuclear Information System (INIS)

    Zoellner, F.G.; Schad, L.R.; Zahn, K.; Schaible, T.; Schoenberg, S.O.; Neff, K.W.

    2012-01-01

    To investigate whether dynamic contrast-enhanced MR imaging of the lung following congenital diaphragmatic hernia repair is feasible at 3.0 T in 2-year-old children and whether associated lung hypoplasia (reflected in reduced pulmonary microcirculation) can be demonstrated in MRI. Twelve children with a mean age 2.0 ± 0.2 years after hernia repair underwent DCE-MRI at 3.0 T using a time-resolved angiography with stochastic trajectories sequence. Quantification of lung perfusion was performed using a pixel-by-pixel deconvolution approach. Six regions of interest were placed (upper, middle and lower parts of right and left lung) to assess differences in pulmonary blood flow (PBF), pulmonary blood volume (PBV) and mean transit time (MTT) while avoiding the inclusion of larger pulmonary arteries and veins. The difference in PBF and PBV between ipsilateral and contralateral lung was significant (P < 0.5). No significant differences could be detected for the MTT (P = 0.5). DCE-MRI in 2-year-old patients is feasible at 3.0 T. Reduced perfusion in the ipsilateral lung is reflected by significantly lower PBF values compared with the contralateral lung. DCE-MRI of the lung in congenital diaphragmatic hernia can help to characterise lung hypoplasia initially and in the long-term follow-up of children after diaphragmatic repair. (orig.)

  16. Quantitative magnetic resonance imaging (MRI) evaluation of cartilage repair after microfracture (MF) treatment for adult unstable osteochondritis dissecans (OCD) in the ankle: correlations with clinical outcome

    International Nuclear Information System (INIS)

    Tao, Hongyue; Lu, Rong; Feng, Xiaoyuan; Chen, Shuang; Shang, Xiliang; Li, Hong; Hua, Yinghui

    2014-01-01

    To quantitatively evaluate cartilage repair after microfracture (MF) for ankle osteochondritis dissecans (OCD) using MRI and analyse correlations between MRI and clinical outcome. Forty-eight patients were recruited and underwent MR imaging, including 3D-DESS, T2-mapping and T2-STIR sequences, and completed American Orthopaedic Foot and Ankle Society (AOFAS) scoring. Thickness index, T2 index of repair tissue (RT) and volume of subchondral bone marrow oedema (BME) were calculated. Subjects were divided into two groups: group A (3-12 months post-op), and group B (12-24 months post-op). Student's t test was used to compare the MRI and AOFAS score between two groups and Pearson's correlation coefficient to analyse correlations between them. Thickness index and AOFAS score of group B were higher than group A (P < 0.001, P < 0.001). T2 index and BME of group B were lower than group A (P < 0.001, P = 0.012). Thickness index, T2 index and BME were all correlated with AOFAS score (r = 0.416, r = -0.475, r = -0.353), but BME was correlated with neither thickness index nor T2 index. Significant improvement from MF can be expected on the basis of the outcomes of quantitative MRI and AOFAS score. MRI was correlated with AOFAS score. BME is insufficient as an independent predictor to evaluate repair quality, but reduction of BME can improve the patient's clinical outcome. (orig.)

  17. Correlation of Fragmented QRS with Right Ventricular Indexes and Fibrosis in Patients with Repaired Tetralogy of Fallot, by Cardiac Magnetic Resonance Imaging

    Directory of Open Access Journals (Sweden)

    Zahra Alizadeh Sani

    2017-09-01

    Full Text Available Background: Repair of tetralogy of fallot (TOF is associated with diffuse myocardial fibrosis. Cardiac magnetic resonance imaging (CMR can visualize the areas with myocardial fibrosis. Presence of fragmented QRS (fQRS implies the presence of the underlying myocardial scar. Despite the strong association between fQRS and myocardial pathologies, the impact of fQRS with myocardial fibrosis in post-TOF correction is unknown. Objectives: Here, we evaluated the possible predictive role of fQRS in repaired TOF cases and its relationship with cardiac function. Patients and Methods: Thirty two patients with previous history of repaired TOF were enrolled. The extent of fQRS was evaluated according to the number of leads with fQRS. After electrocardiographic evaluation, the participants underwent CMR. Results: Results showed a significant relationship between the right ventricular (RV systolic diameter and fQRS (P = 0.014. Also, an inverse linear relationship was found between the number of fQRS edges and RVEF (r = 0.77, P = 0.0001. The mean QRS duration in those with positive and negative fQRS was 132 mm and 115.8 mm (P = 0.0001. Furthermore, a linear correlation was observed between the number of edges and the percentage of scar tissue (r = 0.88, P = 0.001. However, no relevance between gender and fQRS was detected (P = 0.26, and the relationship between RV diastolic diameter and fQRS was not significant (P = 0.1. Thus, fQRS could be used as a marker of RV systolic dysfunction in patients with tetralogy of fallot. Conclusions: We suggested the fQRS as a surrogate indicator of RV dysfunction in repaired TOF patients and showed that diagnostic and prognostic information of the patients were available by fQRS.

  18. The Use of Novel PET Tracers to Image Breast Cancer Biologic Processes Such as Proliferation, DNA Damage and Repair, and Angiogenesis.

    Science.gov (United States)

    Kenny, Laura

    2016-02-01

    The balance between proliferation and cell death is pivotal to breast tumor growth. Because of a combination of environmental and genetic factors leading to activation of oncogenes or inactivation of tumor suppressor genes, these processes become deregulated in cancer. PET imaging of proliferation, angiogenesis, and DNA damage and repair offers the opportunity to monitor therapeutic efficacy to detect changes in tumor biology that may precede physical size reduction and simultaneously allows the study of intratumoral and intertumoral heterogeneity.This review examines recent developments in breast cancer imaging using novel probes. The probes discussed here are not licensed for routine use and are at various stages of development ranging from preclinical development (e.g., the DNA repair marker γH2AX) to clinical validation in larger studies (such as the proliferation probe 3'-deoxy-3'-(18)F-fluorothymidine [(18)F-FLT]). In breast cancer, most studies have focused on proliferation imaging mainly based on (18)F-labeled thymidine analogs. Initial studies have been promising; however, the results of larger validation studies are necessary before being incorporated into routine clinical use. Although there are distinct advantages in using process-specific probes, properties such as metabolism need careful consideration, because high background uptake in the liver due to glucuronidation in the case of (18)F-FLT may limit utility for imaging of liver metastases.Targeting angiogenesis has had some success in tumors such as renal cell carcinoma; however, angiogenesis inhibitors have not been particularly successful in the clinical treatment of breast cancer. This could be potentially attributed to patient selection due to the lack of validated predictive and responsive biomarkers; the quest for a successful noninvasive biomarker for angiogenesis could solve this challenge. Finally, we look at cell death including apoptosis and DNA damage and repair probes, the most well

  19. The Combined Quantification and Interpretation of Multiple Quantitative Magnetic Resonance Imaging Metrics Enlightens Longitudinal Changes Compatible with Brain Repair in Relapsing-Remitting Multiple Sclerosis Patients.

    Science.gov (United States)

    Bonnier, Guillaume; Maréchal, Benedicte; Fartaria, Mário João; Falkowskiy, Pavel; Marques, José P; Simioni, Samanta; Schluep, Myriam; Du Pasquier, Renaud; Thiran, Jean-Philippe; Krueger, Gunnar; Granziera, Cristina

    2017-01-01

    Quantitative and semi-quantitative MRI (qMRI) metrics provide complementary specificity and differential sensitivity to pathological brain changes compatible with brain inflammation, degeneration, and repair. Moreover, advanced magnetic resonance imaging (MRI) metrics with overlapping elements amplify the true tissue-related information and limit measurement noise. In this work, we combined multiple advanced MRI parameters to assess focal and diffuse brain changes over 2 years in a group of early-stage relapsing-remitting MS patients. Thirty relapsing-remitting MS patients with less than 5 years disease duration and nine healthy subjects underwent 3T MRI at baseline and after 2 years including T1, T2, T2* relaxometry, and magnetization transfer imaging. To assess longitudinal changes in normal-appearing (NA) tissue and lesions, we used analyses of variance and Bonferroni correction for multiple comparisons. Multivariate linear regression was used to assess the correlation between clinical outcome and multiparametric MRI changes in lesions and NA tissue. In patients, we measured a significant longitudinal decrease of mean T2 relaxation times in NA white matter ( p  = 0.005) and a decrease of T1 relaxation times in the pallidum ( p  decrease in T1 relaxation time ( p -value  0.4, p  < 0.05). In summary, the combination of multiple advanced MRI provided evidence of changes compatible with focal and diffuse brain repair at early MS stages as suggested by histopathological studies.

  20. Does an Injection of Adipose-Derived Mesenchymal Stem Cells Loaded in Fibrin Glue Influence Rotator Cuff Repair Outcomes? A Clinical and Magnetic Resonance Imaging Study.

    Science.gov (United States)

    Kim, Yong Sang; Sung, Chang Hun; Chung, Sung Hoon; Kwak, Sang Joon; Koh, Yong Gon

    2017-07-01

    The mesenchymal stem cell (MSC)-based tissue engineering approach has been developed to improve the treatment of rotator cuff tears. Hypothesis/Purpose: The purpose was to determine the effect of an injection of adipose-derived MSCs loaded in fibrin glue during arthroscopic rotator cuff repair on clinical outcomes and to evaluate its effect on structural integrity using magnetic resonance imaging (MRI). The hypothesis was that the application of adipose-derived MSCs would improve outcomes after the surgical repair of a rotator cuff tear. Cohort study; Level of evidence, 3. Among 182 patients treated with arthroscopic surgery for a rotator cuff tear, 35 patients treated with arthroscopic rotator cuff repair alone (conventional group) were matched with 35 patients who underwent arthroscopic rotator cuff repair with an injection of adipose-derived MSCs loaded in fibrin glue (injection group) based on sex, age, and lesion size. Outcomes were assessed with respect to the visual analog scale (VAS) for pain, range of motion (ROM) (including forward flexion, external rotation at the side, and internal rotation at the back), and functional measures of the Constant score and University of California, Los Angeles (UCLA) shoulder rating scale. Repaired tendon structural integrity was assessed by using MRI at a minimum of 12 months after surgery, and the mean clinical follow-up was 28.8 ± 4.2 months in the conventional group and 28.3 ± 3.8 months in the injection group. The mean VAS score at rest and during motion improved significantly in both groups after surgery. However, there were no significant differences between the groups at the final follow-up ( P = .256 and .776, respectively). Compared with preoperative measurements, forward flexion and external rotation at the side significantly improved at the final follow-up in both groups (all P rotation at the back were observed in either group ( P = .625 and .834 for the conventional and injection groups, respectively

  1. When is cartilage repair successful?

    International Nuclear Information System (INIS)

    Raudner, M.; Roehrich, S.; Zalaudek, M.; Trattnig, S.; Schreiner, M.M.

    2017-01-01

    Focal cartilage lesions are a cause of long-term disability and morbidity. After cartilage repair, it is crucial to evaluate long-term progression or failure in a reproducible, standardized manner. This article provides an overview of the different cartilage repair procedures and important characteristics to look for in cartilage repair imaging. Specifics and pitfalls are pointed out alongside general aspects. After successful cartilage repair, a complete, but not hypertrophic filling of the defect is the primary criterion of treatment success. The repair tissue should also be completely integrated to the surrounding native cartilage. After some months, the transplants signal should be isointense compared to native cartilage. Complications like osteophytes, subchondral defects, cysts, adhesion and chronic bone marrow edema or joint effusion are common and have to be observed via follow-up. Radiological evaluation and interpretation of postoperative changes should always take the repair method into account. (orig.) [de

  2. CT Imaging Findings and Their Relevance to the Clinical Outcomes After Stent Graft Repair of Penetrating Aortic Ulcers: Six-year, Single-center Experience

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ji Hoon [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology (Korea, Republic of); Angle, John F.; Park, Auh Whan; Anderson, Curtis; Sabri, Saher S.; Turba, Ulku C. [University of Virginia Health System, Division of Angiography, Interventional Radiology and Special Procedures, Department of Radiology (United States); Kern, John A.; Cherry, Kenneth J. [University of Virginia Health System, Department of Surgery (United States); Matsumoto, Alan H., E-mail: ahm4d@virginia.edu [University of Virginia Health System, Division of Angiography, Interventional Radiology and Special Procedures, Department of Radiology (United States)

    2012-12-15

    Purpose: To present the computed tomographic (CT) imaging findings and their relevance to clinical outcomes related to stent graft placement in patients with penetrating aortic ulcers (PAUs). Methods: Medical and imaging records and imaging studies were reviewed for consecutive patients who underwent stent graft repair of a PAU. The distribution and characteristics of the PAU, technical success of stent graft repair, procedure-related complications, associated aortic wall abnormalities, and outcomes of the PAUs at follow-up CT scans were evaluated. Results: Fifteen patients underwent endovascular treatment for PAU. A total of 87% of the PAUs were in the proximal (n = 8) or distal (n = 5) descending thoracic aorta. There was a broad spectrum of PAU depth (mean, 7.9 {+-} 5.6 mm; range 1.5-25.0 mm) and diameter (mean, 13.5 {+-} 9.7 mm; range 2.2-41.0 mm). Atherosclerosis of the thoracic aorta and intramural hematoma were associated in 53 and 93% of the patients, respectively. Technical success was achieved in 100%. Two or more stent grafts were used in five patients. Endoleaks were observed in two patients within 2 weeks of the procedure, both of which resolved spontaneously. At follow-up CT scanning, regression and thrombosis of the PAUs were observed in all patients. The average patient survival was 61.8 months, with an overall mortality of 13% (2 of 15) at follow-up. Neither death was related to the endograft device or the PAU. Conclusion: Endovascular stent graft placement was safe and effective in causing regression and thrombosis of PAUs in this small series of patients. Two or more stent grafts were used in five patients (33%) with associated long-segmental atherosclerotic changes of the thoracic aorta or intramural hematoma.

  3. CT Imaging Findings and Their Relevance to the Clinical Outcomes After Stent Graft Repair of Penetrating Aortic Ulcers: Six-year, Single-center Experience

    International Nuclear Information System (INIS)

    Shin, Ji Hoon; Angle, John F.; Park, Auh Whan; Anderson, Curtis; Sabri, Saher S.; Turba, Ulku C.; Kern, John A.; Cherry, Kenneth J.; Matsumoto, Alan H.

    2012-01-01

    Purpose: To present the computed tomographic (CT) imaging findings and their relevance to clinical outcomes related to stent graft placement in patients with penetrating aortic ulcers (PAUs). Methods: Medical and imaging records and imaging studies were reviewed for consecutive patients who underwent stent graft repair of a PAU. The distribution and characteristics of the PAU, technical success of stent graft repair, procedure-related complications, associated aortic wall abnormalities, and outcomes of the PAUs at follow-up CT scans were evaluated. Results: Fifteen patients underwent endovascular treatment for PAU. A total of 87% of the PAUs were in the proximal (n = 8) or distal (n = 5) descending thoracic aorta. There was a broad spectrum of PAU depth (mean, 7.9 ± 5.6 mm; range 1.5–25.0 mm) and diameter (mean, 13.5 ± 9.7 mm; range 2.2–41.0 mm). Atherosclerosis of the thoracic aorta and intramural hematoma were associated in 53 and 93% of the patients, respectively. Technical success was achieved in 100%. Two or more stent grafts were used in five patients. Endoleaks were observed in two patients within 2 weeks of the procedure, both of which resolved spontaneously. At follow-up CT scanning, regression and thrombosis of the PAUs were observed in all patients. The average patient survival was 61.8 months, with an overall mortality of 13% (2 of 15) at follow-up. Neither death was related to the endograft device or the PAU. Conclusion: Endovascular stent graft placement was safe and effective in causing regression and thrombosis of PAUs in this small series of patients. Two or more stent grafts were used in five patients (33%) with associated long-segmental atherosclerotic changes of the thoracic aorta or intramural hematoma.

  4. Quantitative magnetic resonance imaging (MRI) evaluation of cartilage repair after microfracture (MF) treatment for adult unstable osteochondritis dissecans (OCD) in the ankle: correlations with clinical outcome

    Energy Technology Data Exchange (ETDEWEB)

    Tao, Hongyue; Lu, Rong; Feng, Xiaoyuan; Chen, Shuang [Fudan University, Department of Radiology, Huashan Hospital, Shanghai (China); Shang, Xiliang; Li, Hong; Hua, Yinghui [Fudan University, Department of Sports Medicine, Huashan Hospital, Shanghai (China)

    2014-08-15

    To quantitatively evaluate cartilage repair after microfracture (MF) for ankle osteochondritis dissecans (OCD) using MRI and analyse correlations between MRI and clinical outcome. Forty-eight patients were recruited and underwent MR imaging, including 3D-DESS, T2-mapping and T2-STIR sequences, and completed American Orthopaedic Foot and Ankle Society (AOFAS) scoring. Thickness index, T2 index of repair tissue (RT) and volume of subchondral bone marrow oedema (BME) were calculated. Subjects were divided into two groups: group A (3-12 months post-op), and group B (12-24 months post-op). Student's t test was used to compare the MRI and AOFAS score between two groups and Pearson's correlation coefficient to analyse correlations between them. Thickness index and AOFAS score of group B were higher than group A (P < 0.001, P < 0.001). T2 index and BME of group B were lower than group A (P < 0.001, P = 0.012). Thickness index, T2 index and BME were all correlated with AOFAS score (r = 0.416, r = -0.475, r = -0.353), but BME was correlated with neither thickness index nor T2 index. Significant improvement from MF can be expected on the basis of the outcomes of quantitative MRI and AOFAS score. MRI was correlated with AOFAS score. BME is insufficient as an independent predictor to evaluate repair quality, but reduction of BME can improve the patient's clinical outcome. (orig.)

  5. A statistical shape modelling framework to extract 3D shape biomarkers from medical imaging data: assessing arch morphology of repaired coarctation of the aorta

    International Nuclear Information System (INIS)

    Bruse, Jan L.; McLeod, Kristin; Biglino, Giovanni; Ntsinjana, Hopewell N.; Capelli, Claudio

    2016-01-01

    Medical image analysis in clinical practice is commonly carried out on 2D image data, without fully exploiting the detailed 3D anatomical information that is provided by modern non-invasive medical imaging techniques. In this paper, a statistical shape analysis method is presented, which enables the extraction of 3D anatomical shape features from cardiovascular magnetic resonance (CMR) image data, with no need for manual landmarking. The method was applied to repaired aortic coarctation arches that present complex shapes, with the aim of capturing shape features as biomarkers of potential functional relevance. The method is presented from the user-perspective and is evaluated by comparing results with traditional morphometric measurements. Steps required to set up the statistical shape modelling analyses, from pre-processing of the CMR images to parameter setting and strategies to account for size differences and outliers, are described in detail. The anatomical mean shape of 20 aortic arches post-aortic coarctation repair (CoA) was computed based on surface models reconstructed from CMR data. By analysing transformations that deform the mean shape towards each of the individual patient’s anatomy, shape patterns related to differences in body surface area (BSA) and ejection fraction (EF) were extracted. The resulting shape vectors, describing shape features in 3D, were compared with traditionally measured 2D and 3D morphometric parameters. The computed 3D mean shape was close to population mean values of geometric shape descriptors and visually integrated characteristic shape features associated with our population of CoA shapes. After removing size effects due to differences in body surface area (BSA) between patients, distinct 3D shape features of the aortic arch correlated significantly with EF (r = 0.521, p = .022) and were well in agreement with trends as shown by traditional shape descriptors. The suggested method has the potential to discover previously

  6. A statistical shape modelling framework to extract 3D shape biomarkers from medical imaging data: assessing arch morphology of repaired coarctation of the aorta.

    Science.gov (United States)

    Bruse, Jan L; McLeod, Kristin; Biglino, Giovanni; Ntsinjana, Hopewell N; Capelli, Claudio; Hsia, Tain-Yen; Sermesant, Maxime; Pennec, Xavier; Taylor, Andrew M; Schievano, Silvia

    2016-05-31

    Medical image analysis in clinical practice is commonly carried out on 2D image data, without fully exploiting the detailed 3D anatomical information that is provided by modern non-invasive medical imaging techniques. In this paper, a statistical shape analysis method is presented, which enables the extraction of 3D anatomical shape features from cardiovascular magnetic resonance (CMR) image data, with no need for manual landmarking. The method was applied to repaired aortic coarctation arches that present complex shapes, with the aim of capturing shape features as biomarkers of potential functional relevance. The method is presented from the user-perspective and is evaluated by comparing results with traditional morphometric measurements. Steps required to set up the statistical shape modelling analyses, from pre-processing of the CMR images to parameter setting and strategies to account for size differences and outliers, are described in detail. The anatomical mean shape of 20 aortic arches post-aortic coarctation repair (CoA) was computed based on surface models reconstructed from CMR data. By analysing transformations that deform the mean shape towards each of the individual patient's anatomy, shape patterns related to differences in body surface area (BSA) and ejection fraction (EF) were extracted. The resulting shape vectors, describing shape features in 3D, were compared with traditionally measured 2D and 3D morphometric parameters. The computed 3D mean shape was close to population mean values of geometric shape descriptors and visually integrated characteristic shape features associated with our population of CoA shapes. After removing size effects due to differences in body surface area (BSA) between patients, distinct 3D shape features of the aortic arch correlated significantly with EF (r = 0.521, p = .022) and were well in agreement with trends as shown by traditional shape descriptors. The suggested method has the potential to discover

  7. Meningocele repair

    Science.gov (United States)

    ... is surgery to repair birth defects of the spine and spinal membranes. Meningocele and myelomeningocele ... is covered by a sterile dressing. Your child may then be transferred to a neonatal intensive ...

  8. Does successful rotator cuff repair improve muscle atrophy and fatty infiltration of the rotator cuff? A retrospective magnetic resonance imaging study performed shortly after surgery as a reference.

    Science.gov (United States)

    Hamano, Noritaka; Yamamoto, Atsushi; Shitara, Hitoshi; Ichinose, Tsuyoshi; Shimoyama, Daisuke; Sasaki, Tsuyoshi; Kobayashi, Tsutomu; Kakuta, Yohei; Osawa, Toshihisa; Takagishi, Kenji

    2017-06-01

    Muscle atrophy and fatty infiltration in the rotator cuff muscles are often observed in patients with chronic rotator cuff tears. The recovery from these conditions has not been clarified. Ninety-four patients were included in this study. The improvement in muscle atrophy and fatty infiltration in successfully repaired rotator cuff tears was evaluated by magnetic resonance imaging at 1 year and 2 years after surgery and was compared with muscle atrophy and fatty infiltration observed on magnetic resonance imaging at 2 weeks after surgery to discount any changes due to the medial retraction of the torn tendon. The patients' muscle strength was evaluated in abduction and external rotation. Muscle atrophy and fatty infiltration of the supraspinatus were significantly improved at 2 years after surgery in comparison to 2 weeks after surgery. The subjects' abduction and external rotation strength was also significantly improved at 2 years after surgery in comparison to the preoperative values. Patients whose occupation ratio was improved had a better abduction range of motion, stronger abduction strength, and higher Constant score. Patients whose fatty infiltration was improved had a better range of motion in flexion and abduction, whereas the improvements of muscle strength and the Constant score were similar in the group that showed an improvement of fatty infiltration and the group that did not. Muscle atrophy and fatty infiltration can improve after rotator cuff repair. The strengths of abduction and external rotation were also improved at 2 years after surgery. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  9. The Combined Quantification and Interpretation of Multiple Quantitative Magnetic Resonance Imaging Metrics Enlightens Longitudinal Changes Compatible with Brain Repair in Relapsing-Remitting Multiple Sclerosis Patients

    Directory of Open Access Journals (Sweden)

    Guillaume Bonnier

    2017-09-01

    Full Text Available ObjectiveQuantitative and semi-quantitative MRI (qMRI metrics provide complementary specificity and differential sensitivity to pathological brain changes compatible with brain inflammation, degeneration, and repair. Moreover, advanced magnetic resonance imaging (MRI metrics with overlapping elements amplify the true tissue-related information and limit measurement noise. In this work, we combined multiple advanced MRI parameters to assess focal and diffuse brain changes over 2 years in a group of early-stage relapsing-remitting MS patients.MethodsThirty relapsing-remitting MS patients with less than 5 years disease duration and nine healthy subjects underwent 3T MRI at baseline and after 2 years including T1, T2, T2* relaxometry, and magnetization transfer imaging. To assess longitudinal changes in normal-appearing (NA tissue and lesions, we used analyses of variance and Bonferroni correction for multiple comparisons. Multivariate linear regression was used to assess the correlation between clinical outcome and multiparametric MRI changes in lesions and NA tissue.ResultsIn patients, we measured a significant longitudinal decrease of mean T2 relaxation times in NA white matter (p = 0.005 and a decrease of T1 relaxation times in the pallidum (p < 0.05, which are compatible with edema reabsorption and/or iron deposition. No longitudinal changes in qMRI metrics were observed in controls. In MS lesions, we measured a decrease in T1 relaxation time (p-value < 2.2e−16 and a significant increase in MTR (p-value < 1e−6, suggesting repair mechanisms, such as remyelination, increased axonal density, and/or a gliosis. Last, the evolution of advanced MRI metrics—and not changes in lesions or brain volume—were correlated to motor and cognitive tests scores evolution (Adj-R2 > 0.4, p < 0.05. In summary, the combination of multiple advanced MRI provided evidence of changes compatible with focal and diffuse brain repair at

  10. DNA repair

    International Nuclear Information System (INIS)

    Van Zeeland, A.A.

    1984-01-01

    In this chapter a series of DNA repair pathways are discussed which are available to the cell to cope with the problem of DNA damaged by chemical or physical agents. In the case of microorganisms our knowledge about the precise mechanism of each DNA repair pathway and the regulation of it has been improved considerably when mutants deficient in these repair mechanisms became available. In the case of mammalian cells in culture, until recently there were very little repair deficient mutants available, because in almost all mammalian cells in culture at least the diploid number of chromosomes is present. Therefore the frequency of repair deficient mutants in such populations is very low. Nevertheless because replica plating techniques are improving some mutants from Chinese hamsters ovary cells and L5178Y mouse lymphoma cells are now available. In the case of human cells, cultures obtained from patients with certain genetic diseases are available. A number of cells appear to be sensitive to some chemical or physical mutagens. These include cells from patients suffering from xeroderma pigmentosum, Ataxia telangiectasia, Fanconi's anemia, Cockayne's syndrome. However, only in the case of xeroderma pigmentosum cells, has the sensitivity to ultraviolet light been clearly correlated with a deficiency in excision repair of pyrimidine dimers. Furthermore the work with strains obtained from biopsies from man is difficult because these cells generally have low cloning efficiencies and also have a limited lifespan in vitro. It is therefore very important that more repair deficient mutants will become available from established cell lines from human or animal origin

  11. Sodium magnetic resonance imaging of ankle joint in cadaver specimens, volunteers, and patients after different cartilage repair techniques at 7 T: initial results.

    Science.gov (United States)

    Zbýň, Štefan; Brix, Martin O; Juras, Vladimir; Domayer, Stephan E; Walzer, Sonja M; Mlynarik, Vladimir; Apprich, Sebastian; Buckenmaier, Kai; Windhager, Reinhard; Trattnig, Siegfried

    2015-04-01

    The goal of cartilage repair techniques such as microfracture (MFX) or matrix-associated autologous chondrocyte transplantation (MACT) is to produce repair tissue (RT) with sufficient glycosaminoglycan (GAG) content. Sodium magnetic resonance imaging (MRI) offers a direct and noninvasive evaluation of the GAG content in native cartilage and RT. In the femoral cartilage, this method was able to distinguish between RTs produced by MFX and MACT having different GAG contents. However, it needs to be clarified whether sodium MRI can be useful for evaluating RT in thin ankle cartilage. Thus, the aims of this 7-T study were (1) to validate our sodium MRI protocol in cadaver ankle samples, (2) to evaluate the sodium corrected signal intensities (cSI) in cartilage of volunteers, (3) and to compare sodium values in RT between patients after MFX and MACT treatment. Five human cadaver ankle samples as well as ankles of 9 asymptomatic volunteers, 6 MFX patients and 6 MACT patients were measured in this 7-T study. Sodium values from the ankle samples were compared with histochemically evaluated GAG content. In the volunteers, sodium cSI values were calculated in the cartilages of ankle and subtalar joint. In the patients, sodium cSI in RT and reference cartilage were measured, morphological appearance of RT was evaluated using the magnetic resonance observation of cartilage repair tissue (MOCART) scoring system, and clinical outcome before and after surgery was assessed using the American Orthopaedic Foot and Ankle Society score and Modified Cincinnati Knee Scale. All regions of interest were defined on morphological images and subsequently transferred to the corresponding sodium images. Analysis of variance, t tests, and Pearson correlation coefficients were evaluated. In the patients, significantly lower sodium cSI values were found in RT than in reference cartilage for the MFX (P = 0.007) and MACT patients (P = 0.008). Sodium cSI and MOCART scores in RT did not differ between

  12. Repair process and a repaired component

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, III, Herbert Chidsey; Simpson, Stanley F.

    2018-02-20

    Matrix composite component repair processes are disclosed. The matrix composite repair process includes applying a repair material to a matrix composite component, securing the repair material to the matrix composite component with an external securing mechanism and curing the repair material to bond the repair material to the matrix composite component during the securing by the external securing mechanism. The matrix composite component is selected from the group consisting of a ceramic matrix composite, a polymer matrix composite, and a metal matrix composite. In another embodiment, the repair process includes applying a partially-cured repair material to a matrix composite component, and curing the repair material to bond the repair material to the matrix composite component, an external securing mechanism securing the repair material throughout a curing period, In another embodiment, the external securing mechanism is consumed or decomposed during the repair process.

  13. Long-term follow-up in repaired tetralogy of fallot: can deformation imaging help identify optimal timing of pulmonary valve replacement?

    Science.gov (United States)

    Sabate Rotes, Anna; Bonnichsen, Crystal R; Reece, Chelsea L; Connolly, Heidi M; Burkhart, Harold M; Dearani, Joseph A; Eidem, Benjamin W

    2014-12-01

    Novel echocardiographic techniques based on myocardial deformation have not been extensively evaluated to assess right ventricular (RV) and left ventricular (LV) response after pulmonary valve replacement (PVR) in patients with repaired tetralogy of Fallot. Between 2003 and 2012, 133 patients undergoing first-time PVR after tetralogy of Fallot repair underwent echocardiographic assessment at Mayo Clinic. The last echocardiogram before PVR and 1 year after surgery were retrospectively analyzed with Velocity Vector Imaging. Mean age at PVR was 35.5 ± 16.2 years (54% women). Longitudinal peak systolic strain and strain rate before PVR were low: for the left ventricle, -14.8 ± 3.5% and -0.8 ± 0.2 sec(-1), and for the right ventricle, -16.2 ± 4.1% and -0.9 ± 0.3 sec(-1), respectively. There was no significant change in either parameter after surgery. A close correlation between LV and RV deformational parameters was found before PVR and was maintained after surgery. In the multivariate analysis, patients with better LV and RV peak systolic strain preoperatively were found to have better LV and RV peak systolic strain after surgery (P = .004 and P = .006, respectively). However, patients with the most improvement in deformation were those with worse RV function preoperatively (P = .002). Mean New York Heart Association class at early follow-up improved from 2.2 ± 0.8 to 1.2 ± 0.6 (P tetralogy of Fallot undergoing PVR, and there was no significant change after surgery. However, preoperative systolic deformational parameters were predictive of postoperative ventricular function and New York Heart Association class after PVR and may be helpful to identify optimal timing for surgical intervention in this cohort. Copyright © 2014 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  14. Motorcycle Repair.

    Science.gov (United States)

    Hein, Jim; Bundy, Mike

    This motorcycle repair curriculum guide contains the following ten areas of study: brake systems, clutches, constant mesh transmissions, final drives, suspension, mechanical starting mechanisms, electrical systems, fuel systems, lubrication systems, and overhead camshafts. Each area consists of one or more units of instruction. Each instructional…

  15. Predicting Retear after Repair of Full-Thickness Rotator Cuff Tear: Two-Point Dixon MR Imaging Quantification of Fatty Muscle Degeneration-Initial Experience with 1-year Follow-up.

    Science.gov (United States)

    Nozaki, Taiki; Tasaki, Atsushi; Horiuchi, Saya; Ochi, Junko; Starkey, Jay; Hara, Takeshi; Saida, Yukihisa; Yoshioka, Hiroshi

    2016-08-01

    Purpose To determine the degree of preoperative fatty degeneration within muscles, postoperative longitudinal changes in fatty degeneration, and differences in fatty degeneration between patients with full-thickness supraspinatus tears who do and those who do not experience a retear after surgery. Materials and Methods This prospective study had institutional review board approval and was conducted in accordance with the Committee for Human Research. Informed consent was obtained. Fifty patients with full-thickness supraspinatus tears (18 men, 32 women; mean age, 67.0 years ± 8.0; age range, 41-91 years) were recruited. The degrees of preoperative and postoperative fatty degeneration were quantified by using a two-point Dixon magnetic resonance (MR) imaging sequence; two radiologists measured the mean signal intensity on in-phase [S(In)] and fat [S(Fat)] images. Estimates of fatty degeneration were calculated with "fat fraction" values by using the formula S(Fat)/S(In) within the supraspinatus, infraspinatus, and subscapularis muscles at baseline preoperative and at postoperative 1-year follow-up MR imaging. Preoperative fat fractions in the failed-repair group and the intact-repair group were compared by using the Mann-Whitney U test. Results The preoperative fat fractions in the supraspinatus muscle were significantly higher in the failed-repair group than in the intact-repair group (37.0% vs 19.5%, P muscle tended to progress at 1 year postoperatively in only the failed-repair group. Conclusion MR imaging quantification of preoperative fat fractions by using a two-point Dixon sequence within the rotator cuff muscles may be a viable method for predicting postoperative retear. (©) RSNA, 2016.

  16. Turbine repair process, repaired coating, and repaired turbine component

    Science.gov (United States)

    Das, Rupak; Delvaux, John McConnell; Garcia-Crespo, Andres Jose

    2015-11-03

    A turbine repair process, a repaired coating, and a repaired turbine component are disclosed. The turbine repair process includes providing a turbine component having a higher-pressure region and a lower-pressure region, introducing particles into the higher-pressure region, and at least partially repairing an opening between the higher-pressure region and the lower-pressure region with at least one of the particles to form a repaired turbine component. The repaired coating includes a silicon material, a ceramic matrix composite material, and a repaired region having the silicon material deposited on and surrounded by the ceramic matrix composite material. The repaired turbine component a ceramic matrix composite layer and a repaired region having silicon material deposited on and surrounded by the ceramic matrix composite material.

  17. The Role of Laser Additive Manufacturing Methods of Metals in Repair, Refurbishment and Remanufacturing - Enabling Circular Economy

    Science.gov (United States)

    Leino, Maija; Pekkarinen, Joonas; Soukka, Risto

    Circular economy is an economy model where products, components, and materials are aimed to be kept at their highest utility and value at all times. Repair, refurbishment and remanufacturing processes are procedures aiming at returning the value of the product during its life cycle. Additive manufacturing (AM) is expected to be an enabling technology in circular economy based business models. One of AM process that enables repair, refurbishment and remanufacturing is Directed Energy Deposition. Respectively Powder Bed Fusion enables manufacturing of replacement components on demand. The aim of this study is to identify the current research findings and state of art of utilizing AM in repair, refurbishment and remanufacturing processes of metallic products. The focus is in identifying possibilities of AM in promotion of circular economy and expected environmental benefits based on the found literature. Results of the study indicate significant potential in utilizing AM in repair, refurbishment and remanufacturing activities.

  18. Quantitative magnetic resonance imaging (MRI) evaluation of cartilage repair after microfracture treatment for full-thickness cartilage defect models in rabbit knee joints: correlations with histological findings

    International Nuclear Information System (INIS)

    Tao, Hongyue; Feng, Xiaoyuan; Chen, Shuang; Li, Hong; Hua, Yinghui; Chen, Zhongqing

    2015-01-01

    To evaluate repair tissue (RT) after microfracture treatment for full-thickness cartilage defect models using quantitative MRI and investigate the correlations between MRI and histological findings. The animal experiment was approved by the Animal Care and Use Committee of our college. Thirty-six full-thickness cartilage defect models in rabbit knee joints were assigned to the microfracture or joint debridement group (as control). Each group consisted of 3-week, 5-week, and 7-week subgroups. MR imaging, including a three-dimensional double-echo steady-state sequence (3D-DESS), and T2 mapping were performed at 3, 5, and 7 weeks postoperatively. The thickness and T2 indices of RT were calculated. After MRI scans at each time point, operation sites were removed to make hematoxylin-eosin (H and E)-stained sections. Histological results were evaluated using the modified O'Driscoll score system. Comparisons were made between the two groups with respect to the MRI and histological findings, and correlation analysis was performed within each group. The thickness index and histological O'Driscoll score of RT in the two groups increased over time, while the T2 index decreased. The thickness index and histological O'Driscoll score of the microfracture group were higher than in the joint debridement group at each time point. The T2 index of the microfracture group was lower than in the joint debridement group at 3 weeks (P = 0.006), while it was higher than in the joint debridement group at 5 and 7 weeks (P = 0.025 and 0.025). The thickness index was positively correlated with the histological O'Driscoll score in both groups (microfracture: r s = 0.745, P s = 0.680, P = 0.002). The T2 index was negatively correlated with the histological O'Driscoll score in both groups (microfracture: r s = -0.715, P = 0.002; joint debridement: r s = -0.826, P < 0.001). Significant improvement over time after microfracture can be expected on the basis of the quantitative MRI finding and

  19. Quantitative magnetic resonance imaging (MRI) evaluation of cartilage repair after microfracture treatment for full-thickness cartilage defect models in rabbit knee joints: correlations with histological findings

    Energy Technology Data Exchange (ETDEWEB)

    Tao, Hongyue; Feng, Xiaoyuan; Chen, Shuang [Fudan University, Department of Radiology, Huashan Hospital, Shanghai (China); Li, Hong; Hua, Yinghui [Fudan University, Department of Sports Medicine, Huashan Hospital, Shanghai (China); Chen, Zhongqing [Fudan University, Department of Pathology, Huashan Hospital, Shanghai (China)

    2014-11-26

    To evaluate repair tissue (RT) after microfracture treatment for full-thickness cartilage defect models using quantitative MRI and investigate the correlations between MRI and histological findings. The animal experiment was approved by the Animal Care and Use Committee of our college. Thirty-six full-thickness cartilage defect models in rabbit knee joints were assigned to the microfracture or joint debridement group (as control). Each group consisted of 3-week, 5-week, and 7-week subgroups. MR imaging, including a three-dimensional double-echo steady-state sequence (3D-DESS), and T2 mapping were performed at 3, 5, and 7 weeks postoperatively. The thickness and T2 indices of RT were calculated. After MRI scans at each time point, operation sites were removed to make hematoxylin-eosin (H and E)-stained sections. Histological results were evaluated using the modified O'Driscoll score system. Comparisons were made between the two groups with respect to the MRI and histological findings, and correlation analysis was performed within each group. The thickness index and histological O'Driscoll score of RT in the two groups increased over time, while the T2 index decreased. The thickness index and histological O'Driscoll score of the microfracture group were higher than in the joint debridement group at each time point. The T2 index of the microfracture group was lower than in the joint debridement group at 3 weeks (P = 0.006), while it was higher than in the joint debridement group at 5 and 7 weeks (P = 0.025 and 0.025). The thickness index was positively correlated with the histological O'Driscoll score in both groups (microfracture: r{sub s} = 0.745, P < 0.001; joint debridement: r{sub s} = 0.680, P = 0.002). The T2 index was negatively correlated with the histological O'Driscoll score in both groups (microfracture: r{sub s} = -0.715, P = 0.002; joint debridement: r{sub s} = -0.826, P < 0.001). Significant improvement over time after

  20. Metal artefacts severely hamper magnetic resonance imaging of the rotator cuff tendons after rotator cuff repair with titanium suture anchors.

    Science.gov (United States)

    Schröder, Femke F; Huis In't Veld, Rianne; den Otter, Lydia A; van Raak, Sjoerd M; Ten Haken, Bennie; Vochteloo, Anne J H

    2018-04-01

    The rate of retear after rotator cuff surgery is 17%. Magnetic resonance imaging (MRI) scans are used for confirmative diagnosis of retear. However, because of the presence of titanium suture anchors, metal artefacts on the MRI are common. The present study evaluated the diagnostic value of MRI after rotator cuff tendon surgery with respect to assessing the integrity as well as the degeneration and atrophy of the rotator cuff tendons when titanium anchors are in place. Twenty patients who underwent revision surgery of the rotator cuff as a result of a clinically suspected retear between 2013 and 2015 were included. The MRI scans of these patients were retrospectively analyzed by four specialized shoulder surgeons and compared with intra-operative findings (gold standard). Sensitivity and interobserver agreement among the surgeons in assessing retears as well as the Goutallier and Warner classification were examined. In 36% (range 15% to 50%) of the pre-operative MRI scans, the observers could not review the rotator cuff tendons. When the rotator cuff tendons were assessable, a diagnostic accuracy with a mean sensitivity of 0.84 (0.70 to 1.0) across the surgeons was found, with poor interobserver agreement (kappa = 0.12). Metal artefacts prevented accurate diagnosis from MRI scans of rotator cuff retear in 36% of the patients studied.

  1. Brain aneurysm repair

    Science.gov (United States)

    ... aneurysm repair; Dissecting aneurysm repair; Endovascular aneurysm repair - brain; Subarachnoid hemorrhage - aneurysm ... Your scalp, skull, and the coverings of the brain are opened. A metal clip is placed at ...

  2. High temporal versus high spatial resolution in MR quantitative pulmonary perfusion imaging of two-year old children after congenital diaphragmatic hernia repair

    Energy Technology Data Exchange (ETDEWEB)

    Weidner, M.; Hagelstein, C.; Schoenberg, S.O.; Neff, K.W. [University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Institute of Clinical Radiology and Nuclear Medicine, Mannheim (Germany); Zoellner, F.G.; Schad, L.R. [Heidelberg University, Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Mannheim (Germany); Zahn, K. [University Medical Center Mannheim, Medical Faculty Mannheim, University of Heidelberg, Department of Pediatric Surgery, Mannheim (Germany); Schaible, T. [University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Department of Pediatrics, Mannheim (Germany)

    2014-10-15

    Congenital diaphragmatic hernia (CDH) leads to lung hypoplasia. Using dynamic contrast-enhanced (DCE) MR imaging, lung perfusion can be quantified. As MR perfusion values depend on temporal resolution, we compared two protocols to investigate whether ipsilateral lung perfusion is impaired after CDH, whether there are protocol-dependent differences, and which protocol is preferred. DCE-MRI was performed in 36 2-year old children after CDH on a 3 T MRI system; protocol A (n = 18) based on a high spatial (3.0 s; voxel: 1.25 mm{sup 3}) and protocol B (n = 18) on a high temporal resolution (1.5 s; voxel: 2 mm{sup 3}). Pulmonary blood flow (PBF), pulmonary blood volume (PBV), mean transit time (MTT), and peak-contrast-to-noise-ratio (PCNR) were quantified. PBF was reduced ipsilaterally, with ipsilateral PBF of 45 ± 26 ml/100 ml/min to contralateral PBF of 63 ± 28 ml/100 ml/min (p = 0.0016) for protocol A; and for protocol B, side differences were equivalent (ipsilateral PBF = 62 ± 24 vs. contralateral PBF = 85 ± 30 ml/100 ml/min; p = 0.0034). PCNR was higher for protocol B (30 ± 18 vs. 20 ± 9; p = 0.0294). Protocol B showed higher values of PBF in comparison to protocol A (p always <0.05). Ipsilateral lung perfusion is reduced in 2-year old children following CDH repair. Higher temporal resolution and increased voxel size show a gain in PCNR and lead to higher perfusion values. Protocol B is therefore preferred. (orig.)

  3. Non-invasive characterization of polyurethane-based tissue constructs in a rat abdominal repair model using high frequency ultrasound elasticity imaging.

    Science.gov (United States)

    Yu, Jiao; Takanari, Keisuke; Hong, Yi; Lee, Kee-Won; Amoroso, Nicholas J; Wang, Yadong; Wagner, William R; Kim, Kang

    2013-04-01

    The evaluation of candidate materials and designs for soft tissue scaffolds would benefit from the ability to monitor the mechanical remodeling of the implant site without the need for periodic animal sacrifice and explant analysis. Toward this end, the ability of non-invasive ultrasound elasticity imaging (UEI) to assess temporal mechanical property changes in three different types of porous, biodegradable polyurethane scaffolds was evaluated in a rat abdominal wall repair model. The polymers utilized were salt-leached scaffolds of poly(carbonate urethane) urea, poly(ester urethane) urea and poly(ether ester urethane) urea at 85% porosity. A total of 60 scaffolds (20 each type) were implanted in a full thickness muscle wall replacement in the abdomens of 30 rats. The constructs were ultrasonically scanned every 2 weeks and harvested at weeks 4, 8 and 12 for compression testing or histological analysis. UEI demonstrated different temporal stiffness trends among the different scaffold types, while the stiffness of the surrounding native tissue remained unchanged. The changes in average normalized strains developed in the constructs from UEI compared well with the changes of mean compliance from compression tests and histology. The average normalized strains and the compliance for the same sample exhibited a strong linear relationship. The ability of UEI to identify herniation and to characterize the distribution of local tissue in-growth with high resolution was also investigated. In summary, the reported data indicate that UEI may allow tissue engineers to sequentially evaluate the progress of tissue construct mechanical behavior in vivo and in some cases may reduce the need for interim time point animal sacrifice. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. The Combined Quantification and Interpretation of Multiple Quantitative Magnetic Resonance Imaging Metrics Enlightens Longitudinal Changes Compatible with Brain Repair in Relapsing-Remitting Multiple Sclerosis Patients

    NARCIS (Netherlands)

    Bonnier, G.; Marechal, B.; Fartaria, M.J.; Marques, J.P.; Simioni, S.; Schluep, M.; Du Pasquier, R.; Thiran, J.-P.; Krueger, G.; Granziera, C.

    2017-01-01

    Objective: Quantitative and semi-quantitative MRI (qMRI) metrics provide complementary specificity and differential sensitivity to pathological brain changes compatible with brain inflammation, degeneration and repair. Moreover, advanced MRI metrics with overlapping elements amplify the true

  5. Evaluation of Repair Tension in Arthroscopic Rotator Cuff Repair: Does It Really Matter to the Integrity of the Rotator Cuff?

    Science.gov (United States)

    Kim, Do Hoon; Jang, Young Hoon; Choi, Young Eun; Lee, Hwa-Ryeong; Kim, Sae Hoon

    2016-11-01

    Repair tension of a torn rotator cuff can affect healing after repair. However, a measurement of the actual tension during arthroscopic rotator cuff repair is not feasible. The relationship between repair tension and healing of a rotator cuff repair remains unclear. The purpose of this study was to evaluate the effect of repair tension on healing at the repair site. The hypothesis was that repair tension would be a major factor in determining the anatomic outcome of rotator cuff repair. Cohort study; Level of evidence, 2. Arthroscopic rotator cuff repairs (132 patients) for full-thickness rotator cuff tears were analyzed. An intraoperative model was designed for the estimation of repair tension using a tensiometer. Magnetic resonance imaging (MRI) was performed approximately 1 year (mean [±SD], 12.7 ± 3.2 months) postoperatively for the evaluation of healing at the repair site. Multivariable analysis was performed for tear size, amount of retraction, and fatty degeneration (FD) of rotator cuff muscles. The mean repair tension measured during the arthroscopic procedure was 28.5 ± 23.1 N. There was a statistically significant correlation between tension and tear size (Pearson correlation coefficient [PCC], 0.529; P repair tension also showed a significant inverse correlation with healing at the repair site (SCC, 0.195; P = .025). However, when sex, age, tear size, amount of retraction, tendon quality, and FD of rotator cuff muscles were included for multivariable logistic regression analysis, only FD of the infraspinatus showed an association with the anatomic outcome of repair (Exp(B) = 0.596; P = .010). Our intraoperative model for the estimation of rotator cuff repair tension showed an inverse correlation of repair tension with healing at the repair site, suggesting that complete healing is less likely with high-tension repairs. A significant association was observed on MRI between a high level of FD of the infraspinatus and repaired tendon integrity. © 2016

  6. DNA repair , cell repair and radiosensitivity

    International Nuclear Information System (INIS)

    Zhestyanikov, V.D.

    1983-01-01

    Data obtained in laboratory of radiation cytology and literature data testifying to a considerable role of DNA repair in cell sensitivity to radiation and chemical DNA-tropic agents have been considered. Data pointing to the probability of contribution of inducible repair of DNA into plant cells sensitivity to X-rays are obtained. Certain violations of DNA repair do not result in the increase of radiosensitivity. It is assumed that in the cases unknown mechanisms of DNA repair operate

  7. Current State of Art of Satellite Altimetry

    Directory of Open Access Journals (Sweden)

    Łyszkowicz Adam

    2017-12-01

    Full Text Available One of the fundamental problems of modern geodesy is precise definition of the gravitational field and its changes in time. This is essential in positioning and navigation, geo-physics, geodynamics, oceanography and other sciences related to the climate and Earth’s environment. One of the major sources of gravity data is satellite altimetry that provides gravity data with almost 75% surface of the Earth. Satellite altimetry also provides data to study local, regional and global geophysical processes, the geoid model in the areas of oceans and seas. This technique can be successfully used to study the ocean mean dynamic topography. The results of the investigations and possible products of altimetry will provide a good material for the GGOS (Global Geodetic Observing System and institutions of IAS (International Altimetry Service.

  8. IBA's state of art Proton Therapy System

    International Nuclear Information System (INIS)

    Ternier, Sonja

    2001-01-01

    Full text: In recent years, IBA has developed a state-of-the-art Proton Therapy System that is currently being implemented at the Northeast Proton Therapy Center in Boston. First patient treatment is predicted for the fourth quarter of 2001. The IBA Proton Therapy System consists of a 230 MeV accelerator (a fixed energy isochronous cyclotron), an Energy Selection System that can decrease the energy down to 70 MeV and up to five treatment rooms. There are two types of treatment rooms. A gantry treatment room in which a patient can be treated from virtually any angle or a fixed horizontal beam line aimed at treatments of the of the head and neck. The system is equipped with a Therapy Control System and a Global Safety Management System. The Integrated Therapy Control System is an integrated system ensuring the control of the treatment sessions through independent but networked therapy control units and, therefore, the control of each equipment subsystem. The integrated safety management system, independent of the Therapy Control System, includes a set of hard-wired safety devices, ensuring the safety of the patient and personnel. The system will be capable of delivering proton treatments in four-treatment modes: Double Scattering, Single Scattering, Wobbling and Pencil Beam Scanning. The presentation will show the most important subsystems and treatment modes capabilities as well as the most recent advances in the technology. (author)

  9. Charge sensitive amplifies. The state of arts

    Energy Technology Data Exchange (ETDEWEB)

    Mori, Kunishiro [Clear Pulse Co., Tokyo (Japan)

    1996-07-01

    In the radiation detectors, signals are essentially brought with charges produced by radiation, then it is naturally the best way to use a charge sensitive amplifier (CSA) system to extract those signals. The CSA is thought to be the best amplifier suitable to almost all the radiation detectors, if neglecting economical points of view. The CSA has been only applied to special fields like radiation detection because the concept of `charges` is not so universal against the concepts of `voltage` and `current`. The CSA, however, is low in noise and a high speed amplifier and may be applicable not only to radiation measurement but also piezoelectric devices and also bolometers. In this article, noise in the CSA, basic circuit on the CSA, concepts of `equivalent noise charge` (ENC), a method for the ENC, and importance of the `open-loop gain` in the CSA to achieve better performance of it and how to realize in a practical CSA were described. And, characteristics on a counting rate of the CSA, various circuit used in the CSA, and CSAs which are commercially available at present and special purpose CSAs were also introduced. (G.K.)

  10. Current state of art of satellite altimetry

    Directory of Open Access Journals (Sweden)

    Łyszkowicz Adam Bolesław

    2017-12-01

    Full Text Available One of the fundamental problems of modern geodesy is precise defi nition of the gravitational fi eld and its changes in time. This is essential in positioning and navigation, geophysics, geodynamics, oceanography and other sciences related to the climate and Earth’s environment. One of the major sources of gravity data is satellite altimetry that provides gravity data with almost 75% surface of the Earth. Satellite altimetry also provides data to study local, regional and global geophysical processes, the geoid model in the areas of oceans and seas. This technique can be successfully used to study the ocean mean dynamic topography. The results of the investigations and possible products of altimetry will provide a good material for the GGOS (Global Geodetic Observing System and institutions of IAS (International Altimetry Service. This paper presents the achievements in satellite altimetry in all the above disciplines obtained in the last years. First very shorly basic concept of satellite altimetry is given. In order to obtain the highest accuracy on range measurements over the ocean improved of altimetry waveforms performed on the ground is described. Next, signifi cant improvements of sea and ocean gravity anomalies models developed presently is shown. Study of sea level and its extremes examined, around European and Australian coasts using tide gauges data and satellite altimetry measurements were described. Then investigations of the phenomenon of the ocean tides, calibration of altimeters, studies of rivers and ice-sheets in the last years are given.

  11. Current state of art of satellite altimetry

    Science.gov (United States)

    Łyszkowicz, Adam Bolesław; Bernatowicz, Anna

    2017-12-01

    One of the fundamental problems of modern geodesy is precise defi nition of the gravitational fi eld and its changes in time. This is essential in positioning and navigation, geophysics, geodynamics, oceanography and other sciences related to the climate and Earth's environment. One of the major sources of gravity data is satellite altimetry that provides gravity data with almost 75% surface of the Earth. Satellite altimetry also provides data to study local, regional and global geophysical processes, the geoid model in the areas of oceans and seas. This technique can be successfully used to study the ocean mean dynamic topography. The results of the investigations and possible products of altimetry will provide a good material for the GGOS (Global Geodetic Observing System) and institutions of IAS (International Altimetry Service). This paper presents the achievements in satellite altimetry in all the above disciplines obtained in the last years. First very shorly basic concept of satellite altimetry is given. In order to obtain the highest accuracy on range measurements over the ocean improved of altimetry waveforms performed on the ground is described. Next, signifi cant improvements of sea and ocean gravity anomalies models developed presently is shown. Study of sea level and its extremes examined, around European and Australian coasts using tide gauges data and satellite altimetry measurements were described. Then investigations of the phenomenon of the ocean tides, calibration of altimeters, studies of rivers and ice-sheets in the last years are given.

  12. [Superficial venous thrombosis. A state of art].

    Science.gov (United States)

    Sándor, Tamás

    2017-01-01

    For a long time superficial thrombophlebitis has been thought to be a rather benign condition. Recently, when duplex ultrasound technique is used for the diagnosis more and more often, the disease is proved to be more dangerous than anticipated. Thrombosis propagates to the deep veins in 6-44% and pulmonary embolism was observed on the patients in 1,5-33%. We can calculate venous thromboembolic complications on every fourth patient. Diagnosis is clinical, but duplex ultrasound examination is mandatory, for estimation of the thrombus extent, for exclusion of the deep venous thrombosis and for follow up. Both legs should be checked with ultrasound, because simultaneous deep venous thrombosis can develop on the contralateral limb. Two different forms can be distinguished: superficial venous thrombosis with, or without varicose veins. In cases of spontaneous, non varicous form, especially when the process is migrating or recurrent, a careful clinical examination is necessery for exclusion of malignant diseases and thrombophilia. The treatment options are summarised on the basis of recent international consensus statements. The American and German guidelines are similar. Compression and mobilisation are cornerstones of the therapy. For a short segment thrombosis non steroidal antiinflammatory drugs are effective. For longer segments low molecular-weight heparins are preferred. Information on the effect of the novel oral anticoagulants for the therapy is lacking but they may appear to be effective in the future for this indication. When thrombus is close to the sapheno-femoral or sapheno-popliteal junction crossectomy (high ligation), or low molecular-weight heparin in therapeutic doses are indicated. The term superficial thrombophlebitis should be discouraged, because inflammation and infection is not the primary pathology. It should be called correctly superficial venous thrombosis in order to avoid the unnecessary administration of antibiotics and the misconception, that superficial venous thrombosis is benign disease. Orv. Hetil., 2017, 158(4), 129-138.

  13. Mathematical Fuzzy Logic - State of Art 2001

    Czech Academy of Sciences Publication Activity Database

    Hájek, Petr

    2003-01-01

    Roč. 24, - (2003), s. 71-89 ISSN 0103-9059. [WOLLIC'2001. Brasília, 31.07.2001-03.08.2001] R&D Projects: GA MŠk LN00A056 Keywords : fuzzy logic * many valued logic * basic fuzzy logic BL Subject RIV: BA - General Mathematics http://www.mat.unb.br/~matcont/24_4.pdf

  14. State of art of nuclear telerobots

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Ji Sup; Oh, S C; Park, Y S; Kim, K S

    1997-03-01

    A state-of-the-art survey on telerobotics technology for nuclear applications is made with view to provide technical data base to interested users. Most of the information are gathered from G7 countries with some addition of Korean status of development. Although the bulk of information is focussed on mobile robots, graphic simulation for man-machine interface is also included in the survey. Examples of telerobotics application to nuclear work are investigated. (author). 108 refs., 9 tabs., 64 figs

  15. Dendrogeomorphology in landslide analysis: State of art

    Energy Technology Data Exchange (ETDEWEB)

    Margottini, C [ENEA, Casaccia (Italy). Area Energia Ambiente e Salute; Fantucci, R

    1994-01-01

    This article summarizes the uses of dendrogeomorphological techniques in landslide analysis. It shows how to study different landslides events through the analysis of living trees. Living trees record any slope inclination variation as if they were natural inclinometers moreover they can be used to date landslide and their stabilization process with time.

  16. State-of-art in liquid biofuels

    Energy Technology Data Exchange (ETDEWEB)

    Poitrat, E. [Agency for Environment and Energy Management, Dept. of Agriculture and Bioenergies, Paris (France)

    2001-09-01

    European production of fuel alcohol/ETBE and VOME has now become significant and the research work undertaken i) to reduce the energy requirements and financial costs and ii) to improve environmental benefits, are of major importance. While optimisation still seems necessary, the gain to be achieved should come from the valorisation of co-products and increasing the size of production plants. Larger production plants will make it possible to implement techniques with higher investment costs but having greater energy efficiency. For VOME, the importance of the cost of producing the agricultural feedstock remains very critical, more so than the size of the industrial plant where the size of new plants (100 000 tons up to 250 000 tons) seems a good compromise. Wider use of biofuels will also depend on agricultural policy (setaside status), tax system and harmonisation of the European legislation on oxyfuels. It will improve the greenhouse effect in harmony with the KYOTO agreement. Environmental impacts, and more particularly their quantification in terms of externalities, remain a very crucial topic. In this situation, the quantity of produced biofuels is or will be more 2 millions tons now, including forecasted quantities, which represent 11% of the objective by 2010. Otherwise, the repartition of this current production is very unequal between the different countries of EC. The first production is planned by Germany with 1 millions tons, the second by France with 570 000 tons and the third by Spain with 306 000 tons. Smaller quantities are linked at Italy, Austria, Sweden and Belgium. Other countries have not biofuels production currently. (au)

  17. Bone fracture repair - series (image)

    Science.gov (United States)

    ... by the following methods: a) one or more screws inserted across the break to hold it. b) a steel plate held by screws drilled into the bone. c) a long fluted metal pin with holes in it, is driven down the shaft of the bone ...

  18. Tracheoesophageal fistula repair - series (image)

    Science.gov (United States)

    The baby will be cared for pre-operatively and post-operatively in a neonatal intensive care unit. He/she will be placed in an isolette (incubator) to keep warm. He/she may require oxygen and/or mechanical ventilation. A chest tube may be ...

  19. Repair welding and online radiography

    International Nuclear Information System (INIS)

    Nuding, W.; Grimm, R.; Link, R.; Schroeder, P.; Schroeder, G.

    1990-01-01

    The status of a joint project is reported, which is to develop a computerized testing and welding system for repair work in turbine blades. An X-ray radiographic testing device consisting of microfocus tube, manipulator and image processing system, is modified for this purpose so as to offer a greater number of image points scanned for image processing, and to thus achieve a better resolution for reliable detection of even very small defects. The consistency of the X-ray tube performance, which is a pre-requisite for automation, is to be achieved by a wa tercooled, high-duty tube head. The recording of defect coordinates in the repair zone is done for input into a welding robot to be developed by other partners in the project, so as to allow automated welding work. (orig.) [de

  20. Three-dimensional reconstructed computed tomography-magnetic resonance fusion image-based preoperative planning for surgical procedures for spinal lipoma or tethered spinal cord after myelomeningocele repair. Technical note

    International Nuclear Information System (INIS)

    Bamba, Yohei; Nonaka, Masahiro; Nakajima, Shin; Yamasaki, Mami

    2011-01-01

    Surgical procedures for spinal lipoma or tethered spinal cord after myelomeningocele (MMC) repair are often difficult and complicated, because the anatomical structures can be deformed in complex and unpredictable ways. Imaging helps the surgeon understand the patient's spinal anatomy. Whereas two-dimensional images provide only limited information for surgical planning, three-dimensional (3D) reconstructed computed tomography (CT)-magnetic resonance (MR) fusion images produce clearer representations of the spinal regions. Here we describe simple and quick methods for obtaining 3D reconstructed CT-MR fusion images for preoperative planning of surgical procedures using the iPlan cranial (BrainLAB AG, Feldkirchen, Germany) neuronavigation software. 3D CT images of the vertebral bone were combined with heavily T 2 -weighted MR images of the spinal cord, lipoma, cerebrospinal fluid (CSF) space, and nerve root through a process of fusion, segmentation, and reconstruction of the 3D images. We also used our procedure called 'Image Overlay' to directly project the 3D reconstructed image onto the body surface using an light emitting diode (LED) projector. The final reconstructed 3D images took 10-30 minutes to obtain, and provided the surgeon with a representation of the individual pathological structures, so enabled the design of effective surgical plans, even in patients with bony deformity such as scoliosis. None of the 19 patients treated based on our 3D reconstruction method has had neurological complications, except for CSF leakage. This 3D reconstructed imaging method, combined with Image Overlay, improves the visual understanding of complicated surgical situations, and should improve surgical efficiency and outcome. (author)

  1. Rapid road repair vehicle

    Science.gov (United States)

    Mara, Leo M.

    1998-01-01

    Disclosed is a rapid road repair vehicle capable of moving over a surface to be repaired at near normal posted traffic speeds to scan for and find an the high rate of speed, imperfections in the pavement surface, prepare the surface imperfection for repair by air pressure and vacuum cleaning, applying a correct amount of the correct patching material to effect the repair, smooth the resulting repaired surface, and catalog the location and quality of the repairs for maintenance records of the road surface. The rapid road repair vehicle can repair surface imperfections at lower cost, improved quality, at a higher rate of speed than was was heretofor possible, with significantly reduced exposure to safety and health hazards associated with this kind of road repair activities in the past.

  2. Collision Repair Campaign

    Science.gov (United States)

    The Collision Repair Campaign targets meaningful risk reduction in the Collision Repair source category to reduce air toxic emissions in their communities. The Campaign also helps shops to work towards early compliance with the Auto Body Rule.

  3. Retinal detachment repair

    Science.gov (United States)

    ... medicines Problems breathing You may not recover full vision. ... detachments can be repaired. Failure to repair the retina always results in loss of vision to some degree. After surgery, the quality of ...

  4. Image Fusion Technologies In Commercial Remote Sensing Packages

    OpenAIRE

    Al-Wassai, Firouz Abdullah; Kalyankar, N. V.

    2013-01-01

    Several remote sensing software packages are used to the explicit purpose of analyzing and visualizing remotely sensed data, with the developing of remote sensing sensor technologies from last ten years. Accord-ing to literature, the remote sensing is still the lack of software tools for effective information extraction from remote sensing data. So, this paper provides a state-of-art of multi-sensor image fusion technologies as well as review on the quality evaluation of the single image or f...

  5. Contextual Distance Refining for Image Retrieval

    KAUST Repository

    Islam, Almasri

    2014-01-01

    Recently, a number of methods have been proposed to improve image retrieval accuracy by capturing context information. These methods try to compensate for the fact that a visually less similar image might be more relevant because it depicts the same object. We propose a new quick method for refining any pairwise distance metric, it works by iteratively discovering the object in the image from the most similar images, and then refine the distance metric accordingly. Test show that our technique improves over the state of art in terms of accuracy over the MPEG7 dataset.

  6. Contextual Distance Refining for Image Retrieval

    KAUST Repository

    Islam, Almasri

    2014-09-16

    Recently, a number of methods have been proposed to improve image retrieval accuracy by capturing context information. These methods try to compensate for the fact that a visually less similar image might be more relevant because it depicts the same object. We propose a new quick method for refining any pairwise distance metric, it works by iteratively discovering the object in the image from the most similar images, and then refine the distance metric accordingly. Test show that our technique improves over the state of art in terms of accuracy over the MPEG7 dataset.

  7. Differentiating normal hyaline cartilage from post-surgical repair tissue using fast gradient echo imaging in delayed gadolinium-enhanced MRI (dGEMRIC) at 3 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Trattnig, Siegfried; Pinker, Katja; Welsch, Goetz H. [Medical University of Vienna, MR Center-High field MR, Department of Radiology, Vienna (Austria); Mamisch, Tallal C. [Inselspital Bern, Orthopedic Surgery Department, Bern (Switzerland); Domayer, Stephan [Medical University of Vienna, MR Center-High field MR, Department of Radiology, Vienna (Austria); Medical University of Vienna, Department of Orthopaedics, Vienna (Austria); Szomolanyi, Pavol [Medical University of Vienna, MR Center-High field MR, Department of Radiology, Vienna (Austria); Slovak Academy of Sciences, Department of Imaging Methods, Institute of Measurement Science, Bratislava (Slovakia); Marlovits, Stefan; Kutscha-Lissberg, Florian [Medical University of Vienna, Department of Traumatology, Center for Joints and Cartilage, Vienna (Austria)

    2008-06-15

    The purpose was to evaluate the relative glycosaminoglycan (GAG) content of repair tissue in patients after microfracturing (MFX) and matrix-associated autologous chondrocyte transplantation (MACT) of the knee joint with a dGEMRIC technique based on a newly developed short 3D-GRE sequence with two flip angle excitation pulses. Twenty patients treated with MFX or MACT (ten in each group) were enrolled. For comparability, patients from each group were matched by age (MFX: 37.1 {+-} 16.3 years; MACT: 37.4 {+-} 8.2 years) and postoperative interval (MFX: 33.0 {+-} 17.3 months; MACT: 32.0 {+-} 17.2 months). The {delta} relaxation rate ({delta}R1) for repair tissue and normal hyaline cartilage and the relative {delta}R1 were calculated, and mean values were compared between both groups using an analysis of variance. The mean {delta}R1 for MFX was 1.07 {+-} 0.34 versus 0.32 {+-} 0.20 at the intact control site, and for MACT, 1.90 {+-} 0.49 compared to 0.87 {+-} 0.44, which resulted in a relative {delta}R1 of 3.39 for MFX and 2.18 for MACT. The difference between the cartilage repair groups was statistically significant. The new dGEMRIC technique based on dual flip angle excitation pulses showed higher GAG content in patients after MACT compared to MFX at the same postoperative interval and allowed reducing the data acquisition time to 4 min. (orig.)

  8. Proton Density Fat-Fraction of Rotator Cuff Muscles Is Associated With Isometric Strength 10 Years After Rotator Cuff Repair: A Quantitative Magnetic Resonance Imaging Study of the Shoulder.

    Science.gov (United States)

    Karampinos, Dimitrios C; Holwein, Christian; Buchmann, Stefan; Baum, Thomas; Ruschke, Stefan; Gersing, Alexandra S; Sutter, Reto; Imhoff, Andreas B; Rummeny, Ernst J; Jungmann, Pia M

    2017-07-01

    Quantitative muscle fat-fraction magnetic resonance (MR) imaging techniques correlate with semiquantitative Goutallier scores with failure after rotator cuff (RC) repair. To investigate the relationship of proton density fat fraction (PDFF) of the RC muscles with semiquantitative MR scores, cartilage T2 relaxation times, and clinical isometric strength measurements in patients 10 years after unilateral RC repair. Cross-sectional study; Level of evidence, 3. Bilateral shoulder MR imaging was performed in 13 patients (11 male, 2 female; age, 72 ± 8 years) 10.9 ± 0.4 years after unilateral autologous periosteal flap augmented RC repair (total shoulders assessed, N = 26). Goutallier classification, muscle atrophy, RC tendon integrity, and cartilage defects were determined based on morphological MR sequences. A paracoronal 2D multi-slice multi-echo sequence was used for quantitative cartilage T2 mapping. A chemical shift-encoding-based water-fat separation technique (based on a 6-echo 3D spoiled gradient echo sequence) was used for quantification of the PDFF of RC muscles. Isometric shoulder abduction strength was measured clinically. Mean and SD, Pearson correlation, and partial Spearman correlation were calculated. There were 6 RC full-thickness retears in ipsilateral shoulders and 6 RC full-thickness tears in contralateral shoulders. Isometric shoulder abduction strength was not significantly different between ipsilateral and contralateral shoulders (50 ± 24 N vs 54 ± 24 N; P = .159). The mean PDFF of RC muscles was 11.7% ± 10.4% (ipsilateral, 14.2% ± 8.5%; contralateral, 9.2% ± 7.8%; P = .002). High supraspinatus PDFF correlated significantly with higher Goutallier scores ( R = 0.75, P isometric muscle strength ( R = -0.49, P = .011). This correlation remained significant after adjustment for muscle area measurements and tendon rupture ( R = -0.41, P = .048). More severe cartilage defects at the humerus were significantly associated with higher supraspinatus

  9. Mitral valve repair: an echocardiographic review: Part 2.

    Science.gov (United States)

    Maslow, Andrew

    2015-04-01

    Echocardiographic imaging of the mitral valve before and immediately after repair is crucial to the immediate and long-term outcome. Prior to mitral valve repair, echocardiographic imaging helps determine the feasibility and method of repair. After the repair, echocardiographic imaging displays the new baseline anatomy, assesses function, and determines whether or not further management is necessary. Three-dimensional imaging has improved the assessment of the mitral valve and facilitates communication with the surgeon by providing the surgeon with an image that he/she might see upon opening up the atrium. Further advancements in imaging will continue to improve the understanding of the function and dysfunction of the mitral valve both before and after repair. This information will improve treatment options, timing of invasive therapies, and advancements of repair techniques to yield better short- and long-term patient outcomes. The purpose of this review was to connect the echocardiographic evaluation with the surgical procedure. Bridging the pre- and post-CPB imaging with the surgical procedure allows a greater understanding of mitral valve repair.

  10. Customized Fabrication of Osteochondral Tissue for Articular Joint Surface Repair

    Science.gov (United States)

    2016-09-01

    AWARD NUMBER: W81XWH-14-1-0217 TITLE: Customized Fabrication of Osteochondral Tissue for Articular Joint Surface Repair PRINCIPAL INVESTIGATOR...4. TITLE AND SUBTITLE Customized Fabrication of Osteochondral Tissue for Articular Joint Surface Repair 5a. CONTRACT NUMBER 5b. GRANT NUMBER W81XWH...applicability of these novel osteochondral tissues for articular cartilage repair in rabbit model, using medical imaging-guided PSL. Such an approach may

  11. Multiband and Lossless Compression of Hyperspectral Images

    Directory of Open Access Journals (Sweden)

    Raffaele Pizzolante

    2016-02-01

    Full Text Available Hyperspectral images are widely used in several real-life applications. In this paper, we investigate on the compression of hyperspectral images by considering different aspects, including the optimization of the computational complexity in order to allow implementations on limited hardware (i.e., hyperspectral sensors, etc.. We present an approach that relies on a three-dimensional predictive structure. Our predictive structure, 3D-MBLP, uses one or more previous bands as references to exploit the redundancies among the third dimension. The achieved results are comparable, and often better, with respect to the other state-of-art lossless compression techniques for hyperspectral images.

  12. 'Regular' and 'emergency' repair

    International Nuclear Information System (INIS)

    Luchnik, N.V.

    1975-01-01

    Experiments on the combined action of radiation and a DNA inhibitor using Crepis roots and on split-dose irradiation of human lymphocytes lead to the conclusion that there are two types of repair. The 'regular' repair takes place twice in each mitotic cycle and ensures the maintenance of genetic stability. The 'emergency' repair is induced at all stages of the mitotic cycle by high levels of injury. (author)

  13. Repair kinetics in tissues

    International Nuclear Information System (INIS)

    Thames, H.D.

    1989-01-01

    Monoexponential repair kinetics is based on the assumption of a single, dose-independent rate of repair of sublethal injury in the target cells for tissue injury after exposure to ionizing radiation. Descriptions of the available data based on this assumption have proved fairly successful for both acutely responding (skin, lip mucosa, gut) and late-responding (lung, spinal cord) normal tissues. There are indications of biphasic exponential repair in both categories, however. Unfortunately, the data usually lack sufficient resolution to permit unambiguous determination of the repair rates. There are also indications that repair kinetics may depend on the size of the dose. The data are conflicting on this account, however, with suggestions of both faster and slower repair after larger doses. Indeed, experiments that have been explicitly designed to test this hypothesis show either no effect (gut, spinal cord), faster repair after higher doses (lung, kidney), or slower repair after higher doses (skin). Monoexponential repair appears to be a fairly accurate description that provides an approximation to a more complicated picture, the elucidation of whose details will, however, require very careful and extensive experimental study. (author). 30 refs.; 1 fig

  14. Snowmobile Repair. Teacher Edition.

    Science.gov (United States)

    Hennessy, Stephen S.; Conrad, Rex

    This teacher's guide contains 14 units on snowmobile repair: (1) introduction to snowmobile repair; (2) skis, front suspension, and steering; (3) drive clutch; (4) drive belts; (5) driven clutch; (6) chain drives; (7) jackshafts and axles; (8) rear suspension; (9) tracks; (10) shock absorbers; (11) brakes; (12) engines; (13) ignition and…

  15. DNA repair genes

    International Nuclear Information System (INIS)

    Morimyo, Mitsuoki

    1995-01-01

    Fission yeast S. pombe is assumed to be a good model for cloning of human DNA repair genes, because human gene is normally expressed in S. pombe and has a very similar protein sequence to yeast protein. We have tried to elucidate the DNA repair mechanisms of S. pombe as a model system for those of mammals. (J.P.N.)

  16. DNA repair protocols

    DEFF Research Database (Denmark)

    Bjergbæk, Lotte

    In its 3rd edition, this Methods in Molecular Biology(TM) book covers the eukaryotic response to genomic insult including advanced protocols and standard techniques in the field of DNA repair. Offers expert guidance for DNA repair, recombination, and replication. Current knowledge of the mechanisms...... that regulate DNA repair has grown significantly over the past years with technology advances such as RNA interference, advanced proteomics and microscopy as well as high throughput screens. The third edition of DNA Repair Protocols covers various aspects of the eukaryotic response to genomic insult including...... recent advanced protocols as well as standard techniques used in the field of DNA repair. Both mammalian and non-mammalian model organisms are covered in the book, and many of the techniques can be applied with only minor modifications to other systems than the one described. Written in the highly...

  17. Poolside inspection, repair and reconstitution of LWR fuel elements. Proceedings of a Technical Committee meeting

    International Nuclear Information System (INIS)

    1998-11-01

    The Technical Committee Meeting on Poolside Inspection, repair and reconstruction of LWR Fuel Elements was organize by IAEA upon the recommendations of the International Working Group on Fuel performance Technology and held in Switzerland in October 1997. The purpose of the Meeting was to review the state of art in the area of poolside inspection, repair and reconstruction of light water fuel elements and to evaluate the progress achieved in this area since previous IAEA Meetings on the same topic in 1981 and 1984. The Meeting provided a forum on exchange of information between utilities, fuel designers and other authorities and specialists on a topic of current interest and real concern to industries in many Member States. The respective technologies are widely used or planned to be used in order to identify elementary major causes of fuel failure and to improve fuel utilization by repair and subsequent reuse of fuel elements. The Proceedings includes papers presented at the Meeting each described by a separate abstract

  18. Pixel-wise derivation of pulmonary regurgitation index could influence clinical decision: A phase-contrast MR imaging study on patients with repaired tetralogy of Fallot.

    Science.gov (United States)

    Wu, Pei-Hsin; Chung, Hsiao-Wen; Wu, Ming-Ting; Ko, Cheng-Wen

    2017-08-01

    Regurgitant fraction (RF) measured from 2D phase-contrast MRI has been used as a standard to quantitate the degree of pulmonary regurgitation and serves as a determinant indicator of prognosis for tetralogy of Fallot after surgical repair. This study demonstrated the potential underestimate of RF using the conventional definition and its impact on clinical decision when backward flow occurred during systolic periods. Quantitative flow parameters, including forward flow volume (FFV), backward flow volume (BFV), and RF were estimated by two approaches: One derived from conventional ROI-averaged curve (bulk quantity) and the other in a pixel-wise manner to spatially reflect inhomogeneous flow profile (pixel-wise quantity). Eccentricity at systolic peak (Ecc sys ) was adopted as an index reflecting spatial flow inhomogeneity. Flow parameters derived from ROI-averaged curves on main pulmonary artery were significantly smaller than that of pixel-wise measurement (P 0.3 appears greater compared to the group with Ecc sys < 0.3. Thirteen out of 68 RF values (19%) were underrated while using bulk analysis. The spatial-related flow parameters showed more consistency with the qualitative flow profile pattern for pulmonary arteries, and could be a decisive complement for diagnostic classification. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Advancing research in regeneration and repair of the motor circuitry: non-human primate models and imaging scales as the missing links for successfully translating injectable therapeutics to the clinic.

    Science.gov (United States)

    Tsintou, Magdalini; Dalamagkas, Kyriakos; Makris, Nikos

    2016-01-01

    Regeneration and repair is the ultimate goal of therapeutics in trauma of the central nervous system (CNS). Stroke and spinal cord injury (SCI) are two highly prevalent CNS disorders that remain incurable, despite numerous research studies and the clinical need for effective treatments. Neural engineering is a diverse biomedical field, that addresses these diseases using new approaches. Research in the field involves principally rodent models and biologically active, biodegradable hydrogels. Promising results have been reported in preclinical studies of CNS repair, demonstrating the great potential for the development of new treatments for the brain, spinal cord and peripheral nerve injury. Several obstacles stand in the way of clinical translation of neuroregeneration research. There seems to be a key gap in the translation of research from rodent models to human applications, namely non-human primate models, which constitute a critical bridging step. Applying injectable therapeutics and multimodal neuroimaging in stroke lesions using experimental rhesus monkey models is an avenue that a few research groups have begun to embark on. Understanding and assessing the changes that the injured brain or spinal cord undergoes after an intervention with biodegradable hydrogels in non-human primates seem to represent critical preclinical research steps. Existing innovative models in non-human primates allow us to evaluate the potential of neural engineering and injectable hydrogels. The results of these preliminary studies will pave the way for translating this research into much needed clinical therapeutic approaches. Cutting edge imaging technology using Connectome scanners represents a tremendous advancement, enabling the in vivo, detailed, high-resolution evaluation of these therapeutic interventions in experimental animals. Most importantly, they also allow quantifiable and clinically meaningful correlations with humans, increasing the translatability of these

  20. A new incision for unilateral cleft lip repair developed using animated simulation of repair on computer

    Directory of Open Access Journals (Sweden)

    Sahay A

    2007-01-01

    Full Text Available Background: Unilateral cleft lip repair continues to leave behind some amount of dissatisfaction, as a scope for further improvement is always felt. Most surgeons do not like to deviate from the standard Millard′s/ triangular techniques, or their minor modifications, as no one likes to experiment on the face for fear of unfavourable outcomes. The computer can be utilized as a useful tool in the analysis and planning of surgery and new methods can be developed and attempted subsequently with greater confidence. Aim: We decided to see if an improved lip repair could be developed with the use of computers. Materials and Methods: Analysis of previous lip repairs was done to determine where an improvement was required. Movement of tissues, by simulating an ideal repair, using image warping software, on digital images of cleft lip was studied in animation sequences. A repair which could reproduce these movements was planned. A new incision emerged, which had combined the principles of Millard′s and Randall / Tennyson repairs, with additional features. The new method was performed on 30 cases. Conclusions: The results were encouraging as the shortcomings of these methods were minimized, and the advantages maximized.

  1. Repairing fuel for reinsertion

    International Nuclear Information System (INIS)

    Krukshenk, A.

    1986-01-01

    Eqiupment for nuclear reactor fuel assembly repairing produced by Westinghouse and Brawn Bovery companies is described. Repair of failed fuel assemblies replacement of defect fuel elements gives a noticeable economical effect. Thus if the cost of a new fuel assembly is 450-500 thousand dollars, the replacement of one fuel element in it costs approximately 40-60 thousand dollars. In simple cases repairing includes either removal of failed fuel elements from a fuel assembly and its reinsertion with the rest of fuel elements into the reactor core (reactor refueling), or replacement of unfailed fuel elements from one fuel assembly to a new one (fuel assembly overhaul and reconditioning)

  2. Novel in vivo imaging techniques for trafficking the behavior of subventricular zone neural stem cells (SVZSC) and SVZSC induced functional repair

    Energy Technology Data Exchange (ETDEWEB)

    Anna-Liisa Brownell

    2003-11-28

    Adult progenitor cells hold promise for therapeutic treatment where there has been a disabling loss of function due to death of cells from trauma, disease or aging. However, it will be essential in clinical application to be able to follow the fate of the transplanted cells over time using in vivo tracking methods. We have developed protocol for labeling of progenitor cells to monitor cell trafficking by high resolution magnetic resonance imaging (MRI) and super high resolution positron emission tomography (PET). We have transfected rat subventricular zone stem cells (SVZ, progenitor cell line) and another control cell line (PC12, pheochromocytoma cells) utilizing super paramagnetic iron oxide and poly-L-lysine complex for MR imaging or radiolabeling with 18F-fluor deoxy-D- glucose for PET imaging. The labeled cells were transplanted into the rostral migratory stream (RMS) or striatum of normal or 6-hydroxydopamine lesioned Spraque-Dawley rats. Longitudinal MRI studies (up to 40 days) showed that transplantation site has significant impact to the fate of the cells; when SVZ cells were transplanted into the RMS, cells migrated several centimeter into the olfactory bulb; after transplantation into the striatum, the migration was minimal, only 2 mm. PC 12 cells grew a massive tumor after the striatal implantation and significantly smaller tumor after the RMS implantation. PET studies conducted immediately after transplantation verified the transplantation site. MRI studies were able to show the whole path of migration in one image, since part of the cells die during migration and will get detected because of iron content. Endpoint histological studies verified the cell survival and immunohistochemical studies revealed the differentiation of the transplanted cells into astrocytes and neurons.

  3. Novel in vivo imaging techniques for trafficking the behavior of subventricular zone neural stem cells (SVZSC) and SVZSC induced functional repair

    International Nuclear Information System (INIS)

    Anna-Liisa Brownell

    2003-01-01

    Adult progenitor cells hold promise for therapeutic treatment where there has been a disabling loss of function due to death of cells from trauma, disease or aging. However, it will be essential in clinical application to be able to follow the fate of the transplanted cells over time using in vivo tracking methods. We have developed protocol for labeling of progenitor cells to monitor cell trafficking by high resolution magnetic resonance imaging (MRI) and super high resolution positron emission tomography (PET). We have transfected rat subventricular zone stem cells (SVZ, progenitor cell line) and another control cell line (PC12, pheochromocytoma cells) utilizing super paramagnetic iron oxide and poly-L-lysine complex for MR imaging or radiolabeling with 18F-fluor deoxy-D- glucose for PET imaging. The labeled cells were transplanted into the rostral migratory stream (RMS) or striatum of normal or 6-hydroxydopamine lesioned Spraque-Dawley rats. Longitudinal MRI studies (up to 40 days) showed that transplantation site has significant impact to the fate of the cells; when SVZ cells were transplanted into the RMS, cells migrated several centimeter into the olfactory bulb; after transplantation into the striatum, the migration was minimal, only 2 mm. PC 12 cells grew a massive tumor after the striatal implantation and significantly smaller tumor after the RMS implantation. PET studies conducted immediately after transplantation verified the transplantation site. MRI studies were able to show the whole path of migration in one image, since part of the cells die during migration and will get detected because of iron content. Endpoint histological studies verified the cell survival and immunohistochemical studies revealed the differentiation of the transplanted cells into astrocytes and neurons

  4. DNA Repair Systems

    Indian Academy of Sciences (India)

    DNA molecule which makes it ideal for storage and propagation of genetic information. ... of these errors are broadly referred to as DNA repair. DNA can ... changes occur in the human genome per day. ..... nails, frequent physical and mental.

  5. Brain aneurysm repair - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000123.htm Brain aneurysm repair - discharge To use the sharing features ... this page, please enable JavaScript. You had a brain aneurysm . An aneurysm is a weak area in ...

  6. Ventral hernia repair

    Science.gov (United States)

    ... incarcerated) in the hernia and become impossible to push back in. This is usually painful. The blood supply ... you are lying down or that you cannot push back in. Risks The risks of ventral hernia repair ...

  7. Omphalocele repair - slideshow

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/presentations/100033.htm Omphalocele repair - series—Normal anatomy To use the sharing ... Go to slide 4 out of 4 Overview Omphalocele is an abdominal wall defect at the base ...

  8. Celebrating DNA's Repair Crew.

    Science.gov (United States)

    Kunkel, Thomas A

    2015-12-03

    This year, the Nobel Prize in Chemistry has been awarded to Tomas Lindahl, Aziz Sancar, and Paul Modrich for their seminal studies of the mechanisms by which cells from bacteria to man repair DNA damage that is generated by normal cellular metabolism and stress from the environment. These studies beautifully illustrate the remarkable power of DNA repair to influence life from evolution through disease susceptibility. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Three-dimensional echocardiographic assessment of the repaired mitral valve.

    Science.gov (United States)

    Maslow, Andrew; Mahmood, Feroze; Poppas, Athena; Singh, Arun

    2014-02-01

    This study examined the geometric changes of the mitral valve (MV) after repair using conventional and three-dimensional echocardiography. Prospective evaluation of consecutive patients undergoing mitral valve repair. Tertiary care university hospital. Fifty consecutive patients scheduled for elective repair of the mitral valve for regurgitant disease. Intraoperative transesophageal echocardiography. Assessments of valve area (MVA) were performed using two-dimensional planimetry (2D-Plan), pressure half-time (PHT), and three-dimensional planimetry (3D-Plan). In addition, the direction of ventricular inflow was assessed from the three-dimensional imaging. Good correlations (r = 0.83) and agreement (-0.08 +/- 0.43 cm(2)) were seen between the MVA measured with 3D-Plan and PHT, and were better than either compared to 2D-Plan. MVAs were smaller after repair of functional disease repaired with an annuloplasty ring. After repair, ventricular inflow was directed toward the lateral ventricular wall. Subgroup analysis showed that the change in inflow angle was not different after repair of functional disease (168 to 171 degrees) as compared to those presenting with degenerative disease (168 to 148 degrees; p<0.0001). Three-dimensional imaging provides caregivers with a unique ability to assess changes in valve function after mitral valve repair. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Recommendations to designers aimed at minimizing radiation dose incurred in operation, maintenance, inspection and repair of light-water reactors

    International Nuclear Information System (INIS)

    1978-01-01

    In the framework of the exchange of experience between nuclear power plant operators organized by the services of the Commission of the European Communities an ad-hoc working party elaborated recommendations particularly directed to those concerned with design of light water reactor plants. The necessary design measures which should be followed to minimize radiation dose incurred in operation, maintenance, inspection and repair of such reactors are listed. The recommendations are based on recent views expressed by operating utilities within the Community. It is intended to revise these recommendations at suitable intervals in order to make use of the most recent experience and to keep the report up to date with the actual state of art in nuclear technology

  11. Magnetization transfer analysis of cartilage repair tissue: a preliminary study

    International Nuclear Information System (INIS)

    Palmieri, F.; Keyzer, F. de; Maes, F.; Breuseghem, I. van

    2006-01-01

    To evaluate the magnetization transfer ratio (MTR) after two different cartilage repair procedures, and to compare these data with the MTR of normal cartilage. Twenty-seven patients with a proven cartilage defect were recruited: 13 were treated with autologous chondrocyte implantation (ACI) and 14 were treated with the microfracture technique (MFR). All patients underwent MRI examinations with MT-sequences before the surgical treatment, after 12 months (26 patients) and after 24 months (11 patients). Eleven patients received a complete follow-up study at all three time points (five of the ACI group and six of the MFR group). All images were transferred to a workstation to calculate MTR images. For every MT image set, different ROIs were delineated by two radiologists. Means were calculated per ROI type in the different time frames and in both groups of cartilage repair. The data were analyzed with unpaired t- and ANOVA tests, and by calculating Pearson's correlation coefficient. No significant differences were found in the MTR of fatty bone marrow, muscle and normal cartilage in the different time frames. There was a significant but small difference between the MTR of normal cartilage and the cartilage repair area after 12 months for both procedures. After 24 months, the MTR of ACI repaired cartilage (0.31±0.07) was not significantly different from normal cartilage MTR (0.34±0.05). The MTR of MFR repaired cartilage (0.28±0.02), still showed a significant difference from normal cartilage. The differences between damaged and repaired cartilage MTR are too small to enable MT-imaging to be a useful tool for postoperative follow-up of cartilage repair procedures. There is, however, an evolution towards normal MTR-values in the cartilage repair tissue (especially after ACI repair). (orig.)

  12. Texture Repairing by Unified Low Rank Optimization

    Institute of Scientific and Technical Information of China (English)

    Xiao Liang; Xiang Ren; Zhengdong Zhang; Yi Ma

    2016-01-01

    In this paper, we show how to harness both low-rank and sparse structures in regular or near-regular textures for image completion. Our method is based on a unified formulation for both random and contiguous corruption. In addition to the low rank property of texture, the algorithm also uses the sparse assumption of the natural image: because the natural image is piecewise smooth, it is sparse in certain transformed domain (such as Fourier or wavelet transform). We combine low-rank and sparsity properties of the texture image together in the proposed algorithm. Our algorithm based on convex optimization can automatically and correctly repair the global structure of a corrupted texture, even without precise information about the regions to be completed. This algorithm integrates texture rectification and repairing into one optimization problem. Through extensive simulations, we show our method can complete and repair textures corrupted by errors with both random and contiguous supports better than existing low-rank matrix recovery methods. Our method demonstrates significant advantage over local patch based texture synthesis techniques in dealing with large corruption, non-uniform texture, and large perspective deformation.

  13. Radiobiological significance of DNA repair

    International Nuclear Information System (INIS)

    Kuzin, A.M.

    1978-01-01

    A short outline is given on the history of the problem relating to the repair of radiation injuries, specifically its molecular mechanisms. The most urgent problems which currently confront the researchers are noted. This is a further study on the role of DNA repair in post-radiation recovery, search for ways to activate and suppress DNA repair, investigations into the activity balance of various repair enzymes as well as the problem of errors in the structure of repairing DNA. An important role is attached to the investigations of DNA repair in solving a number of practical problems

  14. Biomedical Imaging and Computational Modeling in Biomechanics

    CERN Document Server

    Iacoviello, Daniela

    2013-01-01

    This book collects the state-of-art and new trends in image analysis and biomechanics. It covers a wide field of scientific and cultural topics, ranging from remodeling of bone tissue under the mechanical stimulus up to optimizing the performance of sports equipment, through the patient-specific modeling in orthopedics, microtomography and its application in oral and implant research, computational modeling in the field of hip prostheses, image based model development and analysis of the human knee joint, kinematics of the hip joint, micro-scale analysis of compositional and mechanical properties of dentin, automated techniques for cervical cell image analysis, and iomedical imaging and computational modeling in cardiovascular disease.   The book will be of interest to researchers, Ph.D students, and graduate students with multidisciplinary interests related to image analysis and understanding, medical imaging, biomechanics, simulation and modeling, experimental analysis.

  15. Recombinational repair: workshop summary

    International Nuclear Information System (INIS)

    Howard-Flanders, P.

    1983-01-01

    Recombinational repair may or may not be synonymous with postreplication repair. Considerable progress has been made in the study of the relevant enzymes, particularly those from bacteria. In this workshop we focus on the recombination enzyme RecA protein. What structural changes take place in the protein and in DNA during repair. How does homologous pairing take place. How is ATP hydrolysis coupled to the stand exchange reaction and the formation of heteroduplx DNA. Turning to another enzyme needed for certain kinds of bacterial recombination, we will ask whether the purified recB protein and recC protein complement each other and are sufficient for exonuclease V activity. In higher cells, we would like to know whether sister exchanges, which occur in bacteria after uv irradiation, are also seen in animal cells

  16. Meniscal repair devices.

    Science.gov (United States)

    Barber, F A; Herbert, M A

    2000-09-01

    Meniscal repair devices not requiring accessory incisions are attractive. Many factors contribute to their clinical effectiveness including their biomechanical characteristics. This study compared several new meniscal repair devices with standard meniscal suture techniques. Using a porcine model, axis-of-insertion loads were applied to various meniscal sutures and repair devices. A single device or stitch was placed in a created meniscal tear and a load applied. Both loads and modes of failure were recorded. The load-to-failure data show stratification into 4 distinct statistical groups. Group A, 113 N for a double vertical stitch; group B, 80 N for a single vertical stitch; group C, 57 N for the BioStinger, 56 N for a horizontal mattress stitch, and 50 N for the T-Fix stitch; and group D, 33 N for the Meniscus Arrow (inserted by hand or gun), 32 N for the Clearfix screw, 31 N for the SDsorb staple, 30 N for the Mitek meniscal repair system, and 27 N for the Biomet staple. The failure mechanism varied. Sutures broke away from the knot. The Meniscus Arrow and BioStinger pulled through the inner rim with the crossbar intact. The Clearfix screw failed by multiple mechanisms, whereas 1 leg of the SDsorb staple always pulled out of the outer rim. The Mitek device usually failed by pullout from the inner rim. The Biomet staple always broke at the crosshead or just below it. Although the surgeon should be aware of the material properties of the repair technique chosen for a meniscal repair, this information is only an indication of device performance and may not correlate with clinical healing results.

  17. DNA repair and cancer

    International Nuclear Information System (INIS)

    Rathore, Shakuntla; Joshi, Pankaj Kumar; Gaur, Sudha

    2012-01-01

    DNA repair refers to a collection of processes by which a cell identifies and corrects damage to the DNA molecule that encode it's genome. In human cells, both normal metabolic activities and environmental factors such as UV light and radiation can cause DNA damage, resulting in as many one million individual molecular lesions per day. Many of these lesions cause structural damage to the DNA molecule and can alter or eliminate the cell's ability to transcribe the gene that the affected DNA encodes. Other lesions include potentially harmful mutation in cell's genome which affect the survival of it's daughter cells after it undergoes mitosis. As a consequence, the DNA repair process is constantly active as it responds to damage in the DNA structure. Inherited mutation that affect DNA repair genes are strongly associated with high cancer risks in humans. Hereditary non polyposis colorectal cancer (HNPCC) is strongly associated with specific mutation in the DNA mismatch repair pathway. BRCA1, BRCA2 two famous mutation conferring a hugely increased risk of breast cancer on carrier, are both associated with a large number of DNA repair pathway, especially NHEJ and homologous recombination. Cancer therapy procedures such as chemotherapy and radiotherapy work by overwhelming the capacity of the cell to repair DNA damage, resulting in cell death. Cells that are most rapidly dividing most typically cancer cells are preferentially affected. The side effect is that other non-cancerous but rapidly dividing cells such as stem cells in the bone marrow are also affected. Modern cancer treatment attempt to localize the DNA damage to cells and tissue only associated with cancer, either by physical means (concentrating the therapeutic agent in the region of the tumor) or by biochemical means (exploiting a feature unique to cancer cells in the body). (author)

  18. Biological radiolesions and repair

    International Nuclear Information System (INIS)

    Laskowski, W.

    1981-01-01

    In 7 chapters, the book answers the following questions: 1) What reactions are induced in biological matter by absorption of radiation energy. 2) In what parts of the cell do the radiation-induced reactions with detectable biological effects occur. 3) In which way are these cell components changed by different qualities of radiation. 4) What are the cell mechanisms by which radiation-induced changes can be repaired. 5) What is the importance of these repair processes for man, his life and evolution. At the end of each chapter, there is a bibliography of relevant publications in this field. (orig./MG) [de

  19. A novel conduit-based coaptation device for primary nerve repair.

    Science.gov (United States)

    Bamba, Ravinder; Riley, D Colton; Kelm, Nathaniel D; Cardwell, Nancy; Pollins, Alonda C; Afshari, Ashkan; Nguyen, Lyly; Dortch, Richard D; Thayer, Wesley P

    2018-06-01

    Conduit-based nerve repairs are commonly used for small nerve gaps, whereas primary repair may be performed if there is no tension on nerve endings. We hypothesize that a conduit-based nerve coaptation device will improve nerve repair outcomes by avoiding sutures at the nerve repair site and utilizing the advantages of a conduit-based repair. The left sciatic nerves of female Sprague-Dawley rats were transected and repaired using a novel conduit-based device. The conduit-based device group was compared to a control group of rats that underwent a standard end-to-end microsurgical repair of the sciatic nerve. Animals underwent behavioral assessments at weekly intervals post-operatively using the sciatic functional index (SFI) test. Animals were sacrificed at four weeks to obtain motor axon counts from immunohistochemistry. A sub-group of animals were sacrificed immediately post repair to obtain MRI images. SFI scores were superior in rats which received conduit-based repairs compared to the control group. Motor axon counts distal to the injury in the device group at four weeks were statistically superior to the control group. MRI tractography was used to demonstrate repair of two nerves using the novel conduit device. A conduit-based nerve coaptation device avoids sutures at the nerve repair site and leads to improved outcomes in a rat model. Conduit-based nerve repair devices have the potential to standardize nerve repairs while improving outcomes.

  20. Composite Repair System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — GTL has developed an innovative composite repair methodology known as the Composite Repair System (CRS). In this phase I effort, CRS is being developed for the...

  1. About the Collision Repair Campaign

    Science.gov (United States)

    EPA developed the Collision Repair Campaign to focus on meaningful risk reduction in the Collision Repair source sector to complement ongoing community air toxics work and attain reductions at a faster rate.

  2. Vesicovaginal Fistula Repair During Pregnancy

    African Journals Online (AJOL)

    Vesicovaginal Fistula Repair During Pregnancy: A Case Report ... Abstract. We report a repair of Vesicovaginal fistula during pregnancy that was aimed at preventing another spontaneous ... practices that encourage teenage marriage and girl.

  3. Ship Repair Workflow Cost Model

    National Research Council Canada - National Science Library

    McDevitt, Mike

    2003-01-01

    The effects of intermittent work patterns and funding on the costs of ship repair and maintenance were modeled for the San Diego region in 2002 for Supervisor of Shipbuilding and Repair (SUPSHIP) San Diego...

  4. Social repair of relationships

    DEFF Research Database (Denmark)

    Fahnøe, Kristian Relsted

    2017-01-01

    organisations, friends and family, and communities. These social relations are viewed as the foundation of citizenship as experienced and practised. Focusing on how two dimensions of lived citizenship, namely rights-responsibilities and belonging, are affected by the social repairs, the chapter shows how...

  5. Comprehensive Small Engine Repair.

    Science.gov (United States)

    Hires, Bill; And Others

    This curriculum guide contains the basic information needed to repair all two- and four-stroke cycle engines. The curriculum covers four areas, each consisting of one or more units of instruction that include performance objectives, suggested activities for teacher and students, information sheets, assignment sheets, job sheets, visual aids,…

  6. Patent urachus repair - slideshow

    Science.gov (United States)

    ... Drugs & Supplements Videos & Tools About MedlinePlus Show Search Search MedlinePlus GO GO About MedlinePlus Site Map FAQs Customer Support Health Topics Drugs & Supplements Videos & Tools Español You Are Here: Home → Medical Encyclopedia → Patent urachus repair - series—Normal anatomy URL of this ...

  7. Patent urachus repair

    Science.gov (United States)

    ... Drugs & Supplements Videos & Tools About MedlinePlus Show Search Search MedlinePlus GO GO About MedlinePlus Site Map FAQs Customer Support Health Topics Drugs & Supplements Videos & Tools Español You Are Here: Home → Medical Encyclopedia → Patent urachus repair URL of this page: //medlineplus.gov/ ...

  8. DNA Repair Systems

    Indian Academy of Sciences (India)

    Thanks to the pioneering research work of Lindahl, Sancar, Modrich and their colleagues, we now have an holistic awareness of how DNA damage occurs and how the damage is rectified in bacteria as well as in higher organisms including human beings. A comprehensive understanding of DNA repair has proven crucial ...

  9. Aircraft Propeller Hub Repair

    Energy Technology Data Exchange (ETDEWEB)

    Muth, Thomas R [ORNL; Peter, William H [ORNL

    2015-02-13

    The team performed a literature review, conducted residual stress measurements, performed failure analysis, and demonstrated a solid state additive manufacturing repair technique on samples removed from a scrapped propeller hub. The team evaluated multiple options for hub repair that included existing metal buildup technologies that the Federal Aviation Administration (FAA) has already embraced, such as cold spray, high velocity oxy-fuel deposition (HVOF), and plasma spray. In addition the team helped Piedmont Propulsion Systems, LLC (PPS) evaluate three potential solutions that could be deployed at different stages in the life cycle of aluminum alloy hubs, in addition to the conventional spray coating method for repair. For new hubs, a machining practice to prevent fretting with the steel drive shaft was recommended. For hubs that were refurbished with some material remaining above the minimal material condition (MMC), a silver interface applied by an electromagnetic pulse additive manufacturing method was recommended. For hubs that were at or below the MMC, a solid state additive manufacturing technique using ultrasonic welding (UW) of thin layers of 7075 aluminum to the hub interface was recommended. A cladding demonstration using the UW technique achieved mechanical bonding of the layers showing promise as a viable repair method.

  10. Role of DNA repair in repair of cytogenetic damages. Slowly repaired DNA injuries involved in cytogenetic damages repair

    International Nuclear Information System (INIS)

    Zaichkina, S.I.; Rozanova, O.M.; Aptikaev, G.F.; Ganassi, E.Eh.

    1989-01-01

    Caffeine was used to study the kinetics of cytogenetic damages repair in Chinese hamster fibroblasts. Its half-time (90 min) was shown to correlate with that of repair of slowly repaired DNA damages. The caffeine-induced increase in the number of irreparable DNA damages, attributed to inhibition of double-strand break repair, is in a quantitative correlation with the effect of the cytogenetic damage modification

  11. DNA repair in human cells

    International Nuclear Information System (INIS)

    Regan, J.D.; Carrier, W.L.; Kusano, I.; Furuno-Fukushi, I.; Dunn, W.C. Jr.; Francis, A.A.; Lee, W.H.

    1982-01-01

    Our primary objective is to elucidate the molecular events in human cells when cellular macromolecules such as DNA are damaged by radiation or chemical agents. We study and characterize (i) the sequence of DNA repair events, (ii) the various modalities of repair, (iii) the genetic inhibition of repair due to mutation, (iv) the physiological inhibition of repair due to mutation, (v) the physiological inhibition of repair due to biochemical inhibitors, and (vi) the genetic basis of repair. Our ultimate goals are to (i) isolate and analyze the repair component of the mutagenic and/or carcinogenic event in human cells, and (ii) elucidate the magnitude and significance of this repair component as it impinges on the practical problems of human irradiation or exposure to actual or potential chemical mutagens and carcinogens. The significance of these studies lies in (i) the ubiquitousness of repair (most organisms, including man, have several complex repair systems), (ii) the belief that mutagenic and carcinogenic events may arise only from residual (nonrepaired) lesions or that error-prone repair systems may be the major induction mechanisms of the mutagenic or carcinogenic event, and (iii) the clear association of repair defects and highly carcinogenic disease states in man [xeroderma pigmentosum (XP)

  12. The journey of DNA repair.

    Science.gov (United States)

    Saini, Natalie

    2015-12-01

    21 years ago, the DNA Repair Enzyme was declared "Molecule of the Year". Today, we are celebrating another "year of repair", with the 2015 Nobel Prize in Chemistry being awarded to Aziz Sancar, Tomas Lindahl and Paul Modrich for their collective work on the different DNA repair pathways.

  13. Ultrasonic image analysis and image-guided interventions.

    Science.gov (United States)

    Noble, J Alison; Navab, Nassir; Becher, H

    2011-08-06

    The fields of medical image analysis and computer-aided interventions deal with reducing the large volume of digital images (X-ray, computed tomography, magnetic resonance imaging (MRI), positron emission tomography and ultrasound (US)) to more meaningful clinical information using software algorithms. US is a core imaging modality employed in these areas, both in its own right and used in conjunction with the other imaging modalities. It is receiving increased interest owing to the recent introduction of three-dimensional US, significant improvements in US image quality, and better understanding of how to design algorithms which exploit the unique strengths and properties of this real-time imaging modality. This article reviews the current state of art in US image analysis and its application in image-guided interventions. The article concludes by giving a perspective from clinical cardiology which is one of the most advanced areas of clinical application of US image analysis and describing some probable future trends in this important area of ultrasonic imaging research.

  14. Repair mechanisms and exposure standards

    International Nuclear Information System (INIS)

    Mills, W.A.

    1978-01-01

    The following topics are discussed; public policy for setting radiation standards; use of linear, nonthreshold theory in setting radiation standards; dose-rate dependence; occupational exposure to radiation; radon inhalation from radium in the soil in the vicinity of the phosphate industry; relation of repair mechanisms for cell survival to cancer induction; application of information on genetic repair to humans and to cancer induction; importance of repair processes in radiation protection standards; corrective factors for repair processes; relation of repair processes to age, sex, and other factors; and population distribution in radiosensitivity

  15. DNA repair deficiency in neurodegeneration

    DEFF Research Database (Denmark)

    Jeppesen, Dennis Kjølhede; Bohr, Vilhelm A; Stevnsner, Tinna V.

    2011-01-01

    Deficiency in repair of nuclear and mitochondrial DNA damage has been linked to several neurodegenerative disorders. Many recent experimental results indicate that the post-mitotic neurons are particularly prone to accumulation of unrepaired DNA lesions potentially leading to progressive...... neurodegeneration. Nucleotide excision repair is the cellular pathway responsible for removing helix-distorting DNA damage and deficiency in such repair is found in a number of diseases with neurodegenerative phenotypes, including Xeroderma Pigmentosum and Cockayne syndrome. The main pathway for repairing oxidative...... base lesions is base excision repair, and such repair is crucial for neurons given their high rates of oxygen metabolism. Mismatch repair corrects base mispairs generated during replication and evidence indicates that oxidative DNA damage can cause this pathway to expand trinucleotide repeats, thereby...

  16. Handbook of Equipment Repair.

    Science.gov (United States)

    1981-05-14

    state of leapin- fn’rw.rd. Tn recent years, many mechanical repair workers often write and ask us to reprint the book. In our consideration, however...ast 4iron 1. .-eat _--OSIS-RTS 5.5 . . 4-5 t4- cast -3.01 -6 ~.0 ’ ɘ.᝱ 5,,:e j?24 2 * 10- 5 aron C l 50 S lcon : Ielt rSSIS-RQTS-s;.4 u a 2.47 5at- .0

  17. Improving image segmentation by learning region affinities

    Energy Technology Data Exchange (ETDEWEB)

    Prasad, Lakshman [Los Alamos National Laboratory; Yang, Xingwei [TEMPLE UNIV.; Latecki, Longin J [TEMPLE UNIV.

    2010-11-03

    We utilize the context information of other regions in hierarchical image segmentation to learn new regions affinities. It is well known that a single choice of quantization of an image space is highly unlikely to be a common optimal quantization level for all categories. Each level of quantization has its own benefits. Therefore, we utilize the hierarchical information among different quantizations as well as spatial proximity of their regions. The proposed affinity learning takes into account higher order relations among image regions, both local and long range relations, making it robust to instabilities and errors of the original, pairwise region affinities. Once the learnt affinities are obtained, we use a standard image segmentation algorithm to get the final segmentation. Moreover, the learnt affinities can be naturally unutilized in interactive segmentation. Experimental results on Berkeley Segmentation Dataset and MSRC Object Recognition Dataset are comparable and in some aspects better than the state-of-art methods.

  18. Unsupervised Performance Evaluation of Image Segmentation

    Directory of Open Access Journals (Sweden)

    Chabrier Sebastien

    2006-01-01

    Full Text Available We present in this paper a study of unsupervised evaluation criteria that enable the quantification of the quality of an image segmentation result. These evaluation criteria compute some statistics for each region or class in a segmentation result. Such an evaluation criterion can be useful for different applications: the comparison of segmentation results, the automatic choice of the best fitted parameters of a segmentation method for a given image, or the definition of new segmentation methods by optimization. We first present the state of art of unsupervised evaluation, and then, we compare six unsupervised evaluation criteria. For this comparative study, we use a database composed of 8400 synthetic gray-level images segmented in four different ways. Vinet's measure (correct classification rate is used as an objective criterion to compare the behavior of the different criteria. Finally, we present the experimental results on the segmentation evaluation of a few gray-level natural images.

  19. Improving Aviation Depot Level Repairable (AVDLR) Inventory and Repair Management

    National Research Council Canada - National Science Library

    Baird, Dennis

    1997-01-01

    .... Additionally, research was conducted to document the management process for determining repair requirements at the Naval Inventory Control Point Philadelphia and how those requirements are accepted...

  20. Imaging

    International Nuclear Information System (INIS)

    Kellum, C.D.; Fisher, L.M.; Tegtmeyer, C.J.

    1987-01-01

    This paper examines the advantages of the use of excretory urography for diagnosis. According to the authors, excretory urography remains the basic radiologic examination of the urinary tract and is the foundation for the evaluation of suspected urologic disease. Despite development of the newer diagnostic modalities such as isotope scanning, ultrasonography, CT, and magnetic resonsance imaging (MRI), excretory urography has maintained a prominent role in ruorradiology. Some indications have been altered and will continue to change with the newer imaging modalities, but the initial evaluation of suspected urinary tract structural abnormalities; hematuria, pyuria, and calculus disease is best performed with excretory urography. The examination is relatively inexpensive and simple to perform, with few contraindictions. Excretory urography, when properly performed, can provide valuable information about the renal parenchyma, pelvicalyceal system, ureters, and urinary bladder

  1. Engineered Heart Repair.

    Science.gov (United States)

    Fujita, B; Zimmermann, W-H

    2017-08-01

    There is a pressing need for the development of advanced heart failure therapeutics. Current state-of-the-art is protection from neurohumoral overstimulation, which fails to address the underlying cause of heart failure, namely loss of cardiomyocytes. Implantation of stem cell-derived cardiomyocytes via tissue-engineered myocardium is being advanced to realize the remuscularization of the failing heart. Here, we discuss pharmacological challenges pertaining to the clinical translation of tissue-engineered heart repair with a focus on engineered heart muscle (EHM). © 2017 American Society for Clinical Pharmacology and Therapeutics.

  2. Hybrid laser arc welding: State-of-art review

    Science.gov (United States)

    Acherjee, Bappa

    2018-02-01

    Hybrid laser arc welding simultaneously utilizes the arc welding and the laser welding, in a common interaction zone. The synergic effects of laser beam and eclectic arc in the same weld pool results in an increase of welding speed and penetration depth along with the enhancement of gap bridging capability and process stability. This paper presents the current status of this hybrid technique in terms of research, developments and applications. Effort is made to present a comprehensive technical know-how about this process through a systematic review of research articles, industrial catalogues, technical notes, etc. In the introductory part of the review, an overview of the hybrid laser arc welding is presented, including operation principle, process requirements, historical developments, benefits and drawbacks of the process. This is followed by a detailed discussion on control parameters those govern the performance of hybrid laser arc welding process. Thereafter, a report of improvements of performance and weld qualities achieved by using hybrid welding process is presented based on review of several research papers. The succeeding sections furnish the examples of industrial applications and the concluding remarks.

  3. The Swedish underground containment studies state of art

    International Nuclear Information System (INIS)

    Lindbo, T.

    1977-01-01

    Since May of 1973 studies of underground siting for nuclear power plants have been going on in Sweden. War protection being the primary aim in accordance with the instructions the first containment study has lead to siting in rock. The second study was aimed at surveying the advantages and disadvantages of a rock sited 1000 MW BWA nuclear power plant from a reactor safety standpoint, compared to a plant above ground. Based on the instructions and considerations within the study group, the following criteria for the plant design have been established: (1). The plant should be designed to give protection against external acts of war with conventional weapons. (2) The plant should have a safety level equal to that of an above ground plant. (3) The design of the plant should moreover utilize the possibilities of improving the safety afforded by rock siting. The chosen technical design of the reactor plant demands a cavern with a 45-50 metre spar. Studies of the stability of such caverns show that a safety level is attainable corresponding to the safety required for the other parts of the nuclear power plant. The conditions are that the rock is of high quality, that necessary strengthening measures are taken and that careful studies of the rock are made before and during the blasting, and also during operation of the plant. The third study now under way is planned to be delivered to the government in June 1977. One part in this study is going deeper in certain questions (safety, operation, maintenance, sabotage, war protection, cost and decommissioning). Another part aims to a broader view of risks and consequences in peace and war and also advantages and disadvantages of nuclear power plant for district heating

  4. STATE OF ART OF BALNEOTHERAPY / THERMALISME IN ROMANIA

    Directory of Open Access Journals (Sweden)

    SURDU Olga

    2015-05-01

    Full Text Available Romania owns almost 30% of European natural resources for balneotherapy/health resort medicine consisting in climate (relief, hydrology and vegetation, including salt mines and caves microclimate, mineral/thermal waters (for bathing and drinking cure, mud/peat and gases.

  5. State-of-art report on the seawater desalination process

    International Nuclear Information System (INIS)

    Hwang, Young Dong; Kim, Young In; Lee, Doo Jung; Chang, Moon Hee

    2000-11-01

    Desalination technologies have been developed over the last 40 years and become a reliable industrial process for water production from sea or blackish water. At present, various desalination processes are available for the effective use of seawater or blackish water as valuable water resources. Since a large amount of energy is required for seawater desalination, the cost of energy is important for desalination. For the regions of severe water shortage, however, desalination is the most economical way of water supply compare to any other alternatives. Currently, water supply by seawater desalination is being increased in the areas of the Caribbean, North African and Middle East. Also, desalination of blackish water is being increased in the south-east region of USA. In general, the distillation process and the membrane technology are used for seawater esalination and the membrane and the electric-dialysis for blackish water. However, the selection of the desalination process is highly dependent on the use of produced water and the local environmental conditions where the desalination plant installed. The local condition is the most important parameters for the selection of the desalination process

  6. State of art in FE-based fuel performance codes

    International Nuclear Information System (INIS)

    Kim, Hyo Chan; Yang, Yong Sik; Kim, Dae Ho; Bang, Je Geon; Kim, Sun Ki; Koo, Yang Hyun

    2013-01-01

    Fuel performance codes approximate this complex behavior using an axisymmetric, axially-stacked, one-dimensional radial representation to save computation cost. However, the need for improved modeling of PCMI and, particularly, the importance of multidimensional capability for accurate fuel performance simulation has been identified as safety margin decreases. Finite element (FE) method that is reliable and proven solution in mechanical field has been introduced into fuel performance codes for multidimensional analysis. The present state of the art in numerical simulation of FE-based fuel performance predominantly involves 2-D axisymmetric model and 3-D volumetric model. The FRAPCON and FRAPTRAN own 1.5-D and 2-D FE model to simulate PCMI and cladding ballooning. In 2-D simulation, the FALCON code, developed by EPRI, is a 2-D (R-Z and R-θ) fully thermal-mechanically coupled steady-state and transient FE-based fuel behavior code. The French codes TOUTATIS and ALCYONE which are 3-D, and typically used to investigate localized behavior. In 2008, the Idaho National Laboratory (INL) has been developing multidimensional (2-D and 3-D) nuclear fuel performance code called BISON. In this paper, the current state of FE-based fuel performance code and their models are presented. Based on investigation into the codes, requirements and direction of development for new FE-based fuel performance code can be discussed. Based on comparison of models in FE-based fuel performance code, status of art in the codes can be discussed. A new FE-based fuel performance code should include typical pellet and cladding models which all codes own. In particular, specified pellet and cladding model such as gaseous swelling and high burnup structure (HBS) model should be developed to improve accuracy of code as well as consider AC condition. To reduce computation cost, the approximated gap and the optimized contact model should be also developed

  7. The diagnosis of plant pathogenic bacteria: a state of art.

    Science.gov (United States)

    Scala, Valeria; Pucci, Nicoletta; Loreti, Stefania

    2018-03-01

    Plant protection plays an important role in agriculture for the food quality and quantity. The diagnosis of plant diseases and the identification of the pathogens are essential prerequisites for their understanding and control. Among the plant pests, the bacterial pathogens have devastating effects on plant productivity and yield. Different techniques (microscopy, serology, biochemical, physiological, molecular tools and culture propagation) are currently used to detect and identify bacterial pathogens. Detection and identification are critical steps for the appropriate application of phytosanitary measures. The "harmonization of phytosanitary regulations and all other areas of official plant protection action" mean the good practices for plant protection and plant material certification. The prevention of diseases progression and spread by early detection are a valuable strategy for proper pest management and disease control. For this purpose, innovative methods aim achieving results within a shorter time and higher performance, to provide rapidly, accurately and reliably diagnosis. In this review, we focus on the techniques for plant bacterial diagnosis and on the regulations for harmonizing plant protection issue.

  8. State-of-art of modern technologies for metals production

    Energy Technology Data Exchange (ETDEWEB)

    Holappa, L [Helsinki Univ. of Technology, Otaniemi (Finland). Lab. of Metallurgy

    1996-12-31

    The future raw materials are becoming lower in metal content and more complex, multimetal concentrates will be utilized. This will give challenges for metallurgists to develop new, efficient and energy saving processes. The main impacts for current and future production technologies come from energy need and environmental issues of the production processes themselves as well as the inevitable energy production for the metal making. Metals production consumes huge amount of energy, roughly 10 pct of the global energy consumption is caused by metallurgists. That is the necessity but it also means energy saving is one of the metallurgical industry have been enormous when looking back to the history. Since the 1960`s the efforts of the industry together with the strict legislation in the industrialized countries have conducted to greatly decreased emissions and improved pollution control. Breakthrough of new processes like copper flash smelting has aided this positive progress

  9. Teaching logic using a state-of-art proof assistant

    Directory of Open Access Journals (Sweden)

    Maxim Hendriks

    2010-06-01

    Full Text Available This article describes the system ProofWeb developed for teaching logic to undergraduate computer science students. The system is based on the higher order proof assistant Coq, and is made available to the students through an interactive web interface. Part of this system is a large database of logic problems. This database will also hold the solutions of the students. The students do not need to install anything to be able to use the system (not even a browser plug-in, and the teachers are able to centrally track progress of the students. The system makes the full power of Coq available to the students, but simultaneously presents the logic problems in a way that is customary in undergraduate logic courses. Both styles of presenting natural deduction proofs (Gentzen-style `tree view' and Fitch-style `box view' are supported. Part of the system is a parser that indicates whether the students used the automation of Coq to solve their problems or that they solved it themselves using only the inference rules of the logic. For these inference rules dedicated tactics for Coq have been developed. The system has already been used in type theory courses and logic undergraduate courses. The ProofWeb system can be tried at http://proofweb.cs.ru.nl/.

  10. Theory of constraints: A state-of-art review

    Directory of Open Access Journals (Sweden)

    Maryam Orouji

    2015-11-01

    Full Text Available The theory of constraints (TOC is a management tool, which considers any manageable system as being limited in reaching more of its objectives by some constraints. According to TOC, there is always, at least, one single constraint, and TOC implements a concentrating process to detect the constraint and restructure the remaining of the organization around it. This paper presents an overview of different perspectives of TOC and its implementation in different industries such as project management, quality management, outsourcing, product mix, make-to-buy, accounting, banking and health care, etc. The results indicate that the method has been extensively implemented in different areas of accounting.

  11. Microgrid testbeds around the world: State of art

    International Nuclear Information System (INIS)

    Hossain, Eklas; Kabalci, Ersan; Bayindir, Ramazan; Perez, Ronald

    2014-01-01

    Highlights: • A detail discussion on microgrid project around the world such as North American, Europe, and Japan. • Key benefits of microgrid, issues with on-site generation, features. • Why we need distributed generation system with a brief introduction. • Distributed generation technologies with cost analysis. • The overview on existing distribution network. - Abstract: This paper deals with the recent evolution of microgrids being used around the world in real life applications as well as laboratory application for research. This study is intended to introduce the subject by reviewing the components level, structure and types of microgrid applications installed as a plant or modeled as a simulation environment. The paper also presents a survey regarding published papers on why the microgrid is required, and what the components and control systems are which constitute the actual microgrid studies. It leads the researcher to see the microgrid in terms of the actual bigger picture of today and creates a new outlook about the potential developments. Additionally, comparison of microgrids in various regions based on several parameters allows researchers to define the required criteria and features of a special microgrid that is chosen for a particular scenario. The authors of this paper also tabulated all the necessary information about microgrids, and proposed a standard microgrid for better power quality and optimizing energy generation. Consequently, it is focused on inadequate knowledge and technology gaps in the power system field with regards to the future, and it is this which has been illustrated for the reader. The existing microgrid testbeds all around the world have been studied and analyzed and several of them are explained as an example in this study. Later, those investigated distribution systems are classified based on region (North America, Europe and Asia) and, as presented in literature, a significant amount of deviation has been found. Several tabulated data sheets have been used to compare and contrast the existing test systems. This research has been concluded with worthy findings and potential areas of research that would enhance the current distributed network as well as introduce microgrid testbeds comprehensively, and aid designers in optimizing green distributed system efficiency for a reliable power supply

  12. State of art in FE-based fuel performance codes

    International Nuclear Information System (INIS)

    Kim, Hyo Chan; Yang, Yong Sik; Kim, Dae Ho; Bang, Je Geon; Kim, Sun Ki; Koo, Yang Hyun

    2013-01-01

    Finite element (FE) method that is reliable and proven solution in mechanical field has been introduced into fuel performance codes for multidimensional analysis. The present state of the art in numerical simulation of FE-based fuel performance predominantly involves 2-D axisymmetric model and 3-D volumetric model. The FRAPCON and FRAPTRAN own 1.5-D and 2-D FE model to simulate PCMI and cladding ballooning. In 2-D simulation, the FALCON code, developed by EPRI, is a 2-D (R-Z and R-θ) fully thermal-mechanically coupled steady-state and transient FE-based fuel behavior code. The French codes TOUTATIS and ALCYONE which are 3-D, and typically used to investigate localized behavior. In 2008, the Idaho National Laboratory (INL) has been developing multidimensional (2-D and 3-D) nuclear fuel performance code called BISON. In this paper, the current state of FE-based fuel performance code and their models are presented. Based on investigation into the codes, requirements and direction of development for new FE-based fuel performance code can be discussed. Based on comparison of models in FE-based fuel performance code, status of art in the codes can be discussed. A new FE-based fuel performance code should include typical pellet and cladding models which all codes own. In particular, specified pellet and cladding model such as gaseous swelling and high burnup structure (HBS) model should be developed to improve accuracy of code as well as consider AC condition. To reduce computation cost, the approximated gap and the optimized contact model should be also developed. Nuclear fuel operates in an extreme environment that induces complex multiphysics phenomena, occurring over distances ranging from inter-atomic spacing to meters, and times scales ranging from microseconds to years. This multiphysics behavior is often tightly coupled, a well known example being the thermomechanical behavior. Adding to this complexity, important aspects of fuel behavior are inherently multidimensional, examples include pellet-clad mechanical interaction (PCMI), fuel fracture, oxide formation, non-axisymmetric neutronics and cooling, and coupling to lower length scale models. Currently, fuel performance codes approximate this complex behavior using an axisymmetric, axially-stacked, one-dimensional radial representation to save computation cost. However, the need for improved modeling of PCMI and, particularly, the importance of multidimensional capability for accurate fuel performance simulation has been identified as safety margin decreases

  13. Zirconia powders production by precipitation: state-of-art review

    International Nuclear Information System (INIS)

    Oliveira, Ana Paula Almeida de; Torem, Mauricio Leonardo

    1994-01-01

    The important role played by zirconia in advanced ceramics can be attributed to its excellent wear and corrosion resistance and refractory character. The polymorphic nature of zirconia made the controlled addition of stabilizing oxides or the constraining effect of a dense ceramics matrix necessary to maintain high parameters had a significant influence on powder properties and on compacted powder behaviour in sintering. Particle shape and size, purity and crystalline structure were specially influenced by precipitation parameters. Therefore, this work presented a review of the state of the art in zirconia powder production and in the recent research on precipitation of that powder. (author)

  14. Childhood obesity: State of art and future research directions

    Directory of Open Access Journals (Sweden)

    Beatriz García Cortés

    2016-04-01

    It is expected to clarify agreements and dissonances in the proposals to combat and prevent childhood obesity. Furthermore, this study aims to project recommendations for future studies involving childhood obesity throw the causes that have been associated disease in the reviewed literature.

  15. Competitive location: a state-of-art review

    Directory of Open Access Journals (Sweden)

    Milad Gorji Ashtiani

    2016-01-01

    Full Text Available This paper provides a review on recent works in the field of competitive facility location models based on the following seven components: 1 Variables, 2 Competition type, 3 Solution space, 4 Customer behavior, 5 Demand type, 6 Number of new facilities and 7 Relocation and redesign possibility. First, the components are introduced and then based on these components; different studies are compared with each other via a proposed taxonomy and finally a review on work of each paper is provided.

  16. State of art in research of ceramic pigments

    International Nuclear Information System (INIS)

    Sulcova, P.; Trojan, M.

    2004-01-01

    The research of our laboratory is focused on investigation of special inorganic pigments, mainly on ceramic pigments. many pigments used just now are questionable from the hygienic point of view. The fact that the most of the pigments contain problematic elements opens necessity of substitution of pigments containing toxic metals (chromium). Yellow ceramic pigments commonly used such as Pb 2 Sb 2 O 7 , PbCrO 4 and CdS are now being expelled from the market because of their toxicity. For this reason the main attention has been directed to the synthesis of new inorganic compounds mainly with yellow, orange and red colour hues, which can be used as pigments for colouring of glaze, plastics or building materials. In harmony with this postulate the pigments based on CeO 2 represent new special inorganic pigments with high-temperature stability have been synthesized. The commercial significance is in thermal, chemical and light stability, combined with their low toxicity. (author)

  17. The Swedish underground containment studies - state of art

    International Nuclear Information System (INIS)

    Lindbo, T.

    1977-01-01

    Since May 1973 studies of underground siting for nuclear power plants have been going on in Sweden. War protection being the primary aim in accordance with the instructions the first containment study has lead to siting in rock or in a pit. Rock siting gives better war protection than pit siting and also has less effect on the landscape, the cost being about equal. The second study was aimed at surveying the advantages and disadvantages of a rock sited 1000 MW BWR nuclear power plant from a reactor safety standpoint, compared to a plant above ground. Based on the instructions and considerations within the study group, the following criteria for the plant design have been established: (1) The plant should be designed to give protection against external acts of war with conventional weapons. (2) The plant should have a safety level equal to that of an above ground plant. It should fulfil the demands set by the authorities for above ground plants with respect to normal operation and accidents. No accidents that can be dealt with above ground may be permitted to result in more serious consequences, nor may they have a higher probability in a plant sited in rock. (3) The design of the plant should moreover utilize the possbilities of improving the safety afforded by rock siting. The criterion about war protection leads to siting in rock or pit, as shown in a previous CDL study. The study group has concentrated its work on rock siting. (Auth.)

  18. Continental transform margins : state of art and future milestones

    Science.gov (United States)

    Basile, Christophe

    2010-05-01

    Transform faults were defined 45 years ago as ‘a new class of fault' (Wilson, 1965), and transform margins were consequently individualized as a new class of continental margins. While transform margins represent 20 to 25 % of the total length of continent-ocean transitions, they were poorly studied, especially when compared with the amount of data, interpretations, models and conceptual progress accumulated on divergent or convergent continental margins. The best studied examples of transform margins are located in the northern part of Norway, south of South Africa, in the gulf of California and on both sides of the Equatorial Atlantic. Here is located the Côte d'Ivoire - Ghana margin, where the more complete data set was acquired, based on numerous geological and geophysical cruises, including ODP Leg 159. The first models that encompassed the structure and evolution of transform margins were mainly driven by plate kinematic reconstructions, and evidenced the diachronic end of tectonic activity and the non-cylindrical character of these margins, with a decreasing strike-slip deformation from the convex to the concave divergent-transform intersections. Further thermo-mechanical models were more specifically designed to explain the vertical displacements along transform margins, and especially the occurrence of high-standing marginal ridges. These thermo-mechanical models involved either heat transfer from oceanic to continental lithospheres across the transform faults or tectonically- or gravity-driven mass transfer in the upper crust. These models were far from fully fit observations, and were frequently dedicated to specific example, and not easily generalizable. Future work on transform continental margins may be expected to fill some scientific gaps, and the definition of working directions can benefit from the studies dedicated to other types of margins. At regional scale the structural and sedimentological variability of transform continental margins has to be emphasized. There is not only one type of transform margins, but as for divergent margins huge changes from one margin to another in both structure and evolution. Multiple types have to be evidenced together with the various parameters that should control the variability. As for divergent margins, special attention should be paid to conjugated transform margins as a tool to assess symmetrical / asymmetrical processes in the oceanic opening. Attention should also be focused on the three-dimensional structure of the intersections between transform and divergent margins, such as the one where the giant oil field Jubilee was recently discovered. There is almost no 3D data available in these area, and their structures still have to be described. An other key point to develop is the mechanical behavior of the lithosphere in and in the vicinity of transform margins. The classical behaviors (isostasy, elastic flexure) have be tested extensively. The localization of the deformation by the transform fault, and the coupling of continental and oceanic lithosphere across the transform fault have to be adressed to understand the evolution of these margins. Again as for divergent margins, new concepts are needed to explain the variations in the post-rift and post-transform subsidence, that can not always be explained by classical subsidence models. But the most remarkable advance in our understanding of transform margins may be related to the study of interactions between the lithosphere and adjacent envelops : deep interactions with the mantle, as underplating, tectonic erosion, or possible lateral crustal flow ; surficial interactions between structural evolution, erosion and sedimentation processes in transform margins may affect the topography and bathymetry, thus the oceanic circulation with possible effects on regional and global climate.

  19. Software Security Assurance: A State-of-Art Report (SAR)

    Science.gov (United States)

    2007-07-31

    analysis of security management processes: includes organizational assessment, asset valuation , threat identification, vulnerability assessment...Available from: http://www.cigital.com/papers/download/bsi2-misuse.pdf 200 Meledath Damodaran , “Secure Software Development Using Use Cases and Misuse

  20. Photogrammetry in mining - possibilities, state of art, perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Sitek, Z.; Mierzwa, W.

    1987-01-01

    Presents a systematic review of the application of aerial and terrestrial photogrammetry in mining. Photogrammetry permits ground subsidence and excavation volume to be determined, maps and cross-sections of surface mines to be plotted and cleavage directions to be found. A method of measuring displacements by so-called time paralaxes is described that allows slope instability and dam and tunnel deformations to be detected. Application of stereophotogrammety for mapping underground headings and chamber workings, for recording and documenting mining accidents is discussed as well as application of photogrammetric probes for surveying postexploitation caverns. Other applications considered are: geologic cartography of underground workings, measuring fissures in shaft lining, investigating ventilation air flow, recording conditions at working faces before and after blasting and examining deformations caused in surface structures by mining. Recent research work conducted in Poland on possibilities offered by combining photogrammetric equipment with computers is outlined. 28 refs., 1 tab

  1. The Swedish underground containment studies: state of art

    International Nuclear Information System (INIS)

    Lindbo, T.

    1978-01-01

    Since 1973 studies of underground siting for nuclear power plants have been going on in Sweden. War protection, being the primary aim in accordance with the instructions, the first containment study has lead to siting in rock or in a pit. Rock sitting gives better war protection than pit sitting and also has less affect on the landscape, the cost being about equal. The second study was aimed at surveying the advantages and disadvantages of a rock sited 1000 MW BWA nuclear power plant from a reactor safety standpoint, compared to a plant above ground. Based on the instructions and considerations within the study group, the following criteria for the plant design have been established. (1) The plant should be designed to give protection against external acts of war with conventional weapons. (2) The plant should have a safety level equal to that of an above ground plant. It should fulfil the demands set by the authorities for above ground plants with respect to normal operation and accident. No accidents that can be dealt with above ground may be permitted to result in more serious consequences, nor may they have a higher probability in a plant sited in rock. (3) The design of the plant should moreover utilize the possibilities of improving the safety afforded by rock siting. (Auth.)

  2. Brachytherapy for coronary restenosis: state of art in 2003

    International Nuclear Information System (INIS)

    Latorzeff, I.; Delannes, M.; Latorzeff, I.; Carrie, D.; Alibelli, M.J.; Bonnet, J.; Duthil, P.

    2003-01-01

    Based on therapeutic approach for benign diseases, vascular brachytherapy decreases smooth vascular muscle cells proliferation and multiplication which lead to the formation of the neo-intima. The radioactive positive action affects arterial recoil due to post angioplasty vessel injury. Randomized studies has shown good angiographic results up to 6 months of follow-up, with 50% in-stent restenosis rate decrease and on the analysed segment as well. Decrease on Mace and TLR show statistically significance. Results don't correlate with emitter and beta emitters had been introduced in France recently. Vascular brachytherapy is actually indicated for in-stent restenosis, there is no evidence to perform this treatment for de novo lesion. Geographic miss, source centering, late thrombosis and pullback procedure may interfere with treatment quality. IVUS allows best target volume determination to a higher quality level. Internationals guidelines such as Eva-Gec-Estro recommendations could increase treatment safety and enable development of an optimal technique. (authors)

  3. Brief review of the state of art in futsal.

    Science.gov (United States)

    Beato, Marco; Coratella, Giuseppe; Schena, Federico

    2016-04-01

    Futsal (the official name of "five side indoor football") has become very popular in recent years, and it counts more than 12 million players in over 100 countries. Futsal is played on a field of 40 x 20 m between 2 teams of 5 players, (four outfield players and the goalkeeper). Despite its rise of popularity, the number of scientific studies related to training modalities as the demands of the match or factors linked to the performance, are quite limited. This brief review aims to explore the few papers published on futsal, taking in consideration some conclusions that can be drawn from previous studies related only to futsal and indoor football players. Future studies should examine the physical demands during the matches, the variation of physical performances during the season and compare different classic training modalities to sport specific exercises, aiming to improve the current knowledge for coaching.

  4. Radiation nursery and occupational exposure: state-of-art

    International Nuclear Information System (INIS)

    Melo, J.A.C.; Huhn, A.; Viana, E.; Rosa, G.; Luz, K.R.; Derech, R.

    2015-01-01

    Documentary research with the aim to reflect on the state of the art in radiological nursing, on the nursing work and occupational hazards they are exposed, from articles produced in Brazil. The survey was conducted in the BVS, the study consisted of seven articles published from 2002 to 2012. Regarding the main variables studied in the articles, issues emerged related to working conditions and biosafety, performance of nurses, legislation, continuing education and difficulties and needs of nursing staff . It was noticed that is recent the interest in the field, but the work of nurses in radiological technologies must be grounded in current scientific knowledge and with proper technique, to the achievement of the desired clinical outcome and to promote their safety, the team and also the patient. (author)

  5. Czochralski method of growing single crystals. State-of-art

    International Nuclear Information System (INIS)

    Bukowski, A.; Zabierowski, P.

    1999-01-01

    Modern Czochralski method of single crystal growing has been described. The example of Czochralski process is given. The advantages that caused the rapid progress of the method have been presented. The method limitations that motivated the further research and new solutions are also presented. As the example two different ways of the technique development has been described: silicon single crystals growth in the magnetic field; continuous liquid feed of silicon crystals growth. (author)

  6. The state of art report on advanced reactor development

    International Nuclear Information System (INIS)

    Kim, Keung Koo; Noh, J. M.; Hwang, D. H. and others

    1999-07-01

    Recently, researches on the advanced power reactors are being performed actively, that maximize the economics and enhance the reactor safety by introducing the inherent safety characteristics and passive safety features. In the development of advanced reactor technology, we developed the inherent core design technologies which can form a foundation of indigenous technologies to provide the basic technology for the core design of the domestic advanced reactor. In this report, we examined the neutronics design technologies and core thermal hydraulics design technologies for advanced reactors performed all over the world. Major efforts are focussed on the soluble boron free core design technology and high conversion core design technology. In addition to these, new conceptual core, such as a supercritical core, design technology development was also reviewed. The characteristics of critical heat flux have been investigated for non-square lattice rod bundles, such as triangular lattice and wire wrap lattice. Based on the status of advanced reactor development, the soluble boron free and hexagonal lattice core design technologies are elementary technology for the domestic advanced reactor core. These elementary core technologies would enhance the reactor safety and improve the economics. (author). 71 refs., 31 tabs., 74 figs

  7. Radiotherapy of maxillary sinuses carcinoma: state of art

    International Nuclear Information System (INIS)

    Chargari, C.; Bauduceau, O.; Vedrine, L.; Fayolle, M.; Ceccaldi, B.; Chargari, C.; Magne, N.; Haen, P.; Conessa, C.

    2009-01-01

    Maxillary sinus carcinomas are rare malignancies of the face, characterized by high local relapsing rate. Modalities of treatment are without consensus and respective roles of radiation therapy and surgery remain controversial. As those malignancies are often diagnosed at locally advanced stage, radiation therapy may frequently be used for patients having unresectable advanced disease. Nevertheless, surgery remains treatment of choice for more localized malignancies, in association with systematic postoperative radiotherapy. For those patients whose prognosis remains pejorative, it is necessary to precise the role of radiotherapy in first intention for inoperable tumors, to define necessity for nodal treatment performing and evaluate the place of neo-adjuvant or concomitant chemotherapy in a multimodal strategy. (authors)

  8. State-of-art of modern technologies for metals production

    Energy Technology Data Exchange (ETDEWEB)

    Holappa, L. [Helsinki Univ. of Technology, Otaniemi (Finland). Lab. of Metallurgy

    1995-12-31

    The future raw materials are becoming lower in metal content and more complex, multimetal concentrates will be utilized. This will give challenges for metallurgists to develop new, efficient and energy saving processes. The main impacts for current and future production technologies come from energy need and environmental issues of the production processes themselves as well as the inevitable energy production for the metal making. Metals production consumes huge amount of energy, roughly 10 pct of the global energy consumption is caused by metallurgists. That is the necessity but it also means energy saving is one of the metallurgical industry have been enormous when looking back to the history. Since the 1960`s the efforts of the industry together with the strict legislation in the industrialized countries have conducted to greatly decreased emissions and improved pollution control. Breakthrough of new processes like copper flash smelting has aided this positive progress

  9. Plastic flexible films waste management - A state of art review.

    Science.gov (United States)

    Horodytska, O; Valdés, F J; Fullana, A

    2018-04-21

    Plastic flexible films are increasingly used in many applications due to their lightness and versatility. In 2014, the amount of plastic films represented 34% of total plastic packaging produced in UK. The flexible film waste generation rises according to the increase in number of applications. Currently, in developed countries, about 50% of plastics in domestic waste are films. Moreover, about 615,000 tonnes of agricultural flexible waste are generated in the EU every year. A review of plastic films recycling has been conducted in order to detect the shortcomings and establish guidelines for future research. This paper reviews plastic films waste management technologies from two different sources: post-industrial and post-consumer. Clean and homogeneous post-industrial waste is recycled through closed-loop or open-loop mechanical processes. The main differences between these methods are the quality and the application of the recycled materials. Further research should be focused on closing the loops to obtain the highest environmental benefits of recycling. This could be accomplished through minimizing the material degradation during mechanical processes. Regarding post-consumer waste, flexible films from agricultural and packaging sectors have been assessed. The agricultural films and commercial and industrial flexible packaging are recycled through open-loop mechanical recycling due to existing selective waste collection routes. Nevertheless, the contamination from the use phase adversely affects the quality of recycled plastics. Therefore, upgrading of current washing lines is required. On the other hand, household flexible packaging shows the lowest recycling rates mainly because of inefficient sorting technologies. Delamination and compatibilization methods should be further developed to ensure the recycling of multilayer films. Finally, Life Cycle Assessment (LCA) studies on waste management have been reviewed. A lack of thorough LCA on plastic films waste management systems was identified. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. State-of-art report on the seawater desalination process

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Young Dong; Kim, Young In; Lee, Doo Jung; Chang, Moon Hee

    2000-11-01

    Desalination technologies have been developed over the last 40 years and become a reliable industrial process for water production from sea or blackish water. At present, various desalination processes are available for the effective use of seawater or blackish water as valuable water resources. Since a large amount of energy is required for seawater desalination, the cost of energy is important for desalination. For the regions of severe water shortage, however, desalination is the most economical way of water supply compare to any other alternatives. Currently, water supply by seawater desalination is being increased in the areas of the Caribbean, North African and Middle East. Also, desalination of blackish water is being increased in the south-east region of USA. In general, the distillation process and the membrane technology are used for seawater esalination and the membrane and the electric-dialysis for blackish water. However, the selection of the desalination process is highly dependent on the use of produced water and the local environmental conditions where the desalination plant installed. The local condition is the most important parameters for the selection of the desalination process.

  11. State of Art of Cancer Pharmacogenomics in Latin American Populations

    Directory of Open Access Journals (Sweden)

    Andrés López-Cortés

    2017-05-01

    Full Text Available Over the past decades, several studies have shown that tumor-related somatic and germline alterations predicts tumor prognosis, drug response and toxicity. Latin American populations present a vast geno-phenotypic diversity due to the great interethnic and interracial mixing. This genetic flow leads to the appearance of complex characteristics that allow individuals to adapt to endemic environments, such as high altitude or extreme tropical weather. These genetic changes, most of them subtle and unexplored, could establish a mutational profile to develop new pharmacogenomic therapies specific for Latin American populations. In this review, we present the current status of research on somatic and germline alterations in Latin America compared to those found in Caucasian and Asian populations.

  12. State-of-art and future development of activation autoradiography

    International Nuclear Information System (INIS)

    Babikova, Yu.F.; Gusakov, A.A.; Kazakov, S.S.; Minaev, V.M.

    1984-01-01

    Autoradiography as one of the long-term techniques of local analysis of chemical inhomogenities of materials finds a wide application. Autoradiographic techniques using sample activation by charged particles and nuclear decay radiation detection are most favourable from the analytical point of view. The same applies to activation by neutrons and gamma rays and the detection of nuclear reaction products. By choosing optimum conditions and modes of conducting activation autoradiographic research it is possible to determine selectively such elements as lithium, boron, nitrogen, oxygen, sodium, silicon and phosphorus in most of the metal matrices

  13. Repairing Organisational Legitimacy : the Case of the New Zealand Police

    Directory of Open Access Journals (Sweden)

    Grant Samkin

    2010-09-01

    Full Text Available This paper illustrates how the New Zealand Police use non-financial annual report disclosures in response toadverse media publicity. This longitudinal case study spans the reporting periods ending 30 June 2000through to 30 June 2007. It involves a detailed examination of the narrative disclosures and images containedin the annual reports, including the Commissioner’s Overview and the Outcome Reports during this time.Three controversial items covered by the media were traced through the annual reports to establish whetherthe New Zealand Police use image repair discourse supplemented by semiotics in non-financial annual reportdisclosures to repair organisational legitimacy. The analysis found that non-financial disclosures together withimage repair discourse strategies were used by the New Zealand Police, a public sector agency, to repairorganisational legitimacy. This paper provides a valuable contribution to researchers and practitioners as itextends the understanding of how public sector agencies use non-financial annual report disclosures.

  14. Promoting peripheral myelin repair.

    Science.gov (United States)

    Zhou, Ye; Notterpek, Lucia

    2016-09-01

    Compared to the central nervous system (CNS), peripheral nerves have a remarkable ability to regenerate and remyelinate. This regenerative capacity to a large extent is dependent on and supported by Schwann cells, the myelin-forming glial cells of the peripheral nervous system (PNS). In a variety of paradigms, Schwann cells are critical in the removal of the degenerated tissue, which is followed by remyelination of newly-regenerated axons. This unique plasticity of Schwann cells has been the target of myelin repair strategies in acute injuries and chronic diseases, such as hereditary demyelinating neuropathies. In one approach, the endogenous regenerative capacity of Schwann cells is enhanced through interventions such as exercise, electrical stimulation or pharmacological means. Alternatively, Schwann cells derived from healthy nerves, or engineered from different tissue sources have been transplanted into the PNS to support remyelination. These transplant approaches can then be further enhanced by exercise and/or electrical stimulation, as well as by the inclusion of biomaterial engineered to support glial cell viability and neurite extension. Advances in our basic understanding of peripheral nerve biology, as well as biomaterial engineering, will further improve the functional repair of myelinated peripheral nerves. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Mapping of repair genes

    International Nuclear Information System (INIS)

    Hori, Tadaaki

    1985-01-01

    Chromosome mapping of repair genes involved in U.V. sensitivity is reported. Twenty-three of 25 hybrid cells were resistant to U.V. light. Survival curves of 2 U.V.-resistant cell strains, which possessed mouse chromosomes and human chromosome No.7 - 16, were similar to those of wild strain (L5178Y). On the other hand, survival curves of U.V.-sensitive hybrid cells was analogous to those of Q31. There was a definitive difference in the frequency of inducible chromosome aberrations between U.V. resistant and sensitive mouse-human hybrid cells. U.V.-resistant cell strains possessed the ability of excision repair. Analysis of karyotype in hybrid cells showed that the difference in U.V. sensitivity is dependent upon whether or not human chromosome No.13 is present. Synteny test on esterase D-determining locus confirmed that there is an agreement between the presence of chromosome No.13 and the presence of human esterase D activity. These results led to a conclusion that human genes which compensate recessive character of U.V.-sensitive mutant strain, Q31, with mouse-human hybrid cells are located on the locus of chromosome No.13. (Namekawa, K.)

  16. Anterior cruciate ligament repair - past, present and future.

    Science.gov (United States)

    Mahapatra, Piyush; Horriat, Saman; Anand, Bobby S

    2018-06-15

    This article provides a detailed narrative review on the history and current concepts surrounding ligamentous repair techniques in athletic patients. In particular, we will focus on the anterior cruciate ligament (ACL) as a case study in ligament injury and ligamentous repair techniques. PubMed (MEDLINE), EMBASE and Cochrane Library databases for papers relating to primary anterior cruciate ligament reconstruction were searched by all participating authors. All relevant historical papers were included for analysis. Additional searches of the same databases were made for papers relating to biological enhancement of ligament healing. The poor capacity of the ACL to heal is one of the main reasons why the current gold standard surgical treatment for an ACL injury in an athletic patient is ACL reconstruction with autograft from either the hamstrings or patella tendon. It is hypothesised that by preserving and repairing native tissues and negating the need for autograft that primary ACL repair may represent a key step change in the treatment of ACL injuries. The history of primary ACL repair will be discussed and the circumstances that led to the near-abandonment of primary ACL repair techniques will be reviewed. There has been a recent resurgence in interest with regards to primary ACL repair. Improvements in imaging now allow for identification of tear location, with femoral-sided injuries, being more suitable for repair. We will discuss in details strategies for improving the mechanical and biological environment in order to allow primary healing to occur. In particular, we will explain mechanical supplementation such as Internal Brace Ligament Augmentation and Dynamic Intraligamentary Stabilisation techniques. These are novel techniques that aim to protect the primary repair by providing a stabilising construct that connects the femur and the tibia, thus bridging the repair. In addition, biological supplementation is being investigated as an adjunct and we will

  17. Surgical repair of large cyclodialysis clefts.

    Science.gov (United States)

    Gross, Jacob B; Davis, Garvin H; Bell, Nicholas P; Feldman, Robert M; Blieden, Lauren S

    2017-05-11

    To describe a new surgical technique to effectively close large (>180 degrees) cyclodialysis clefts. Our method involves the use of procedures commonly associated with repair of retinal detachment and complex cataract extraction: phacoemulsification with placement of a capsular tension ring followed by pars plana vitrectomy and gas tamponade with light cryotherapy. We also used anterior segment optical coherence tomography (OCT) as a noninvasive mechanism to determine the extent of the clefts and compared those results with ultrasound biomicroscopy (UBM) and gonioscopy. This technique was used to repair large cyclodialysis clefts in 4 eyes. All 4 eyes had resolution of hypotony and improvement of visual acuity. One patient had an intraocular pressure spike requiring further surgical intervention. Anterior segment OCT imaging in all 4 patients showed a more extensive cleft than UBM or gonioscopy. This technique is effective in repairing large cyclodialysis clefts. Anterior segment OCT more accurately predicted the extent of each cleft, while UBM and gonioscopy both underestimated the size of the cleft.

  18. Handbook of adhesive bonded structural repair

    CERN Document Server

    Wegman, Raymond F

    1992-01-01

    Provides repair methods for adhesive bonded and composite structures; identifies suitable materials and equipment for repairs; describes damage evaluation criteria and techniques, and methods of inspection before and after repair.

  19. [Constitutional mismatch repair deficiency syndrome

    NARCIS (Netherlands)

    Jongmans, M.C.J.; Gidding, C.E.M.; Loeffen, J.; Wesseling, P.; Mensenkamp, A.; Hoogerbrugge, N.

    2015-01-01

    BACKGROUND: Constitutional mismatch repair deficiency (CMMR-D) syndrome is characterised by a significantly increased risk for developing cancer in childhood. It arises when both parents have a mutation in the same mismatch repair gene and pass it on to their child. CASE DESCRIPTION: An 8-year-old

  20. Clamp wins pipe repair prize

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2001-04-01

    This paper describes the permanent pipeline repair system, developed by Tekmar, which is powered by seawater hydraulics and is easily installed and tested by any workclass remotely operated vehicle (rov). Details are given of the two main components of the system, namely, the diverless high pressure split repair clamp and the rov-operated tool to install it.

  1. Nucleotide excision repair in yeast

    NARCIS (Netherlands)

    Eijk, Patrick van

    2012-01-01

    Nucleotide Excision Repair (NER) is a conserved DNA repair pathway capable of removing a broad spectrum of DNA damage. In human cells a defect in NER leads to the disorder Xeroderma pigmentosum (XP). The yeast Saccharomyces cerevisiae is an excellent model organism to study the mechanism of NER. The

  2. My journey to DNA repair.

    Science.gov (United States)

    Lindahl, Tomas

    2013-02-01

    I completed my medical studies at the Karolinska Institute in Stockholm but have always been devoted to basic research. My longstanding interest is to understand fundamental DNA repair mechanisms in the fields of cancer therapy, inherited human genetic disorders and ancient DNA. I initially measured DNA decay, including rates of base loss and cytosine deamination. I have discovered several important DNA repair proteins and determined their mechanisms of action. The discovery of uracil-DNA glycosylase defined a new category of repair enzymes with each specialized for different types of DNA damage. The base excision repair pathway was first reconstituted with human proteins in my group. Cell-free analysis for mammalian nucleotide excision repair of DNA was also developed in my laboratory. I found multiple distinct DNA ligases in mammalian cells, and led the first genetic and biochemical work on DNA ligases I, III and IV. I discovered the mammalian exonucleases DNase III (TREX1) and IV (FEN1). Interestingly, expression of TREX1 was altered in some human autoimmune diseases. I also showed that the mutagenic DNA adduct O(6)-methylguanine (O(6)mG) is repaired without removing the guanine from DNA, identifying a surprising mechanism by which the methyl group is transferred to a residue in the repair protein itself. A further novel process of DNA repair discovered by my research group is the action of AlkB as an iron-dependent enzyme carrying out oxidative demethylation. Copyright © 2013. Production and hosting by Elsevier Ltd.

  3. The journey of DNA repair

    OpenAIRE

    Saini, Natalie

    2015-01-01

    21 years ago, the DNA Repair Enzyme was declared “Molecule of the Year”. Today, we are celebrating another “year of repair”, with the 2015 Nobel Prize in Chemistry being awarded to Aziz Sancar, Tomas Lindahl and Paul Modrich for their collective work on the different DNA repair pathways.

  4. Robotic repair of retrocaval ureter: A case series | Nayak | African ...

    African Journals Online (AJOL)

    Subjects and methods: This is a prospective case series of five consecutive patients who underwent robotic retrocaval ureter repair at our institute from August 2006 to September 2009. Pre-operative imaging included intravenous urogram, contrast enhanced CT scan and diuretic renography. All cases were done through a ...

  5. MR imaging of the traumatic triangular fibrocartilaginous complex tear

    Science.gov (United States)

    Griffith, James F.; Fung, Cindy S. Y.; Lee, Ryan K. L.; Tong, Cina S. L.; Wong, Clara W. Y.; Tse, Wing Lim; Ho, Pak Cheong

    2017-01-01

    Triangular fibrocartilage complex is a major stabilizer of the distal radioulnar joint (DRUJ). However, triangular fibrocartilage complex (TFCC) tear is difficult to be diagnosed on MRI for its intrinsic small and thin structure with complex anatomy. The purpose of this article is to review the anatomy of TFCC, state of art MRI imaging technique, normal appearance and features of tear on MRI according to the Palmar’s classification. Atypical tear and limitations of MRI in diagnosis of TFCC tear are also discussed. PMID:28932701

  6. Relevance Feedback in Content Based Image Retrieval: A Review

    Directory of Open Access Journals (Sweden)

    Manesh B. Kokare

    2011-01-01

    Full Text Available This paper provides an overview of the technical achievements in the research area of relevance feedback (RF in content-based image retrieval (CBIR. Relevance feedback is a powerful technique in CBIR systems, in order to improve the performance of CBIR effectively. It is an open research area to the researcher to reduce the semantic gap between low-level features and high level concepts. The paper covers the current state of art of the research in relevance feedback in CBIR, various relevance feedback techniques and issues in relevance feedback are discussed in detail.

  7. Total Endovascular Aortic Repair in a Patient with Marfan Syndrome.

    Science.gov (United States)

    Amako, Mau; Spear, Rafaëlle; Clough, Rachel E; Hertault, Adrien; Azzaoui, Richard; Martin-Gonzalez, Teresa; Sobocinski, Jonathan; Haulon, Stéphan

    2017-02-01

    The aim of this study is to describe a total endovascular aortic repair with branched and fenestrated endografts in a young patient with Marfan syndrome and a chronic aortic dissection. Open surgery is the gold standard to treat aortic dissections in patients with aortic disease and Marfan syndrome. In 2000, a 38-year-old man with Marfan syndrome underwent open ascending aorta repair for an acute type A aortic dissection. One year later, a redo sternotomy was performed for aortic valve replacement. In 2013, the patient presented with endocarditis and pulmonary infection, which necessitated tracheostomy and temporary dialysis. In 2014, the first stage of the endovascular repair was performed using an inner branched endograft to exclude a 77-mm distal arch and descending thoracic aortic aneurysm. In 2015, a 63-mm thoracoabdominal aortic aneurysm was excluded by implantation of a 4-fenestrated endograft. Follow-up after both endovascular repairs was uneventful. Total aortic endovascular repair was successfully performed to treat a patient with arch and thoraco-abdominal aortic aneurysm associated with chronic aortic dissection and Marfan syndrome. The postoperative images confirmed patency of the endograft and its branches, and complete exclusion of the aortic false lumen. Endovascular repair is a treatment option in patients with connective tissue disease who are not candidates for open surgery. Long-term follow-up is required to confirm these favorable early outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Procedures for maintenance and repairs

    International Nuclear Information System (INIS)

    Pickel, E.

    1981-01-01

    After a general review of the operation experience in the history of more than 12 operating years, the organization in the plant will be shown with special aspect to quality assurance, capacity of the workshops and connected groups as radiation protection, chemical laboratories etc. The number, time intervals and manpower effort for the repeating tests will be discussed. Reasons and examples for back-fitting activities in the plant are given. Besides special repair and maintenance procedures as repair of the steam generators, in-service inspection of the reactor pressure vessel, repair of a feed-water pipe and repair of the core structure in the pressure vessel, the general system to handle maintenance and repair-work in the KWO-plant will be shown. This includes also the detailed planning of the annual refueling and revision of the plant. (orig./RW)

  9. Wound repair in Pocillopora

    Science.gov (United States)

    Rodríguez-Villalobos, Jenny Carolina; Work, Thierry M.; Calderon-Aguileraa, Luis Eduardo

    2016-01-01

    Corals routinely lose tissue due to causes ranging from predation to disease. Tissue healing and regeneration are fundamental to the normal functioning of corals, yet we know little about this process. We described the microscopic morphology of wound repair in Pocillopora damicornis. Tissue was removed by airbrushing fragments from three healthy colonies, and these were monitored daily at the gross and microscopic level for 40 days. Grossly, corals healed by Day 30, but repigmentation was not evident at the end of the study (40 d). On histology, from Day 8 onwards, tissues at the lesion site were microscopically indistinguishable from adjacent normal tissues with evidence of zooxanthellae in gastrodermis. Inflammation was not evident. P. damicornis manifested a unique mode of regeneration involving projections of cell-covered mesoglea from the surface body wall that anastomosed to form gastrovascular canals.

  10. Repairing Nanoparticle Surface Defects.

    Science.gov (United States)

    Marino, Emanuele; Kodger, Thomas E; Crisp, Ryan W; Timmerman, Dolf; MacArthur, Katherine E; Heggen, Marc; Schall, Peter

    2017-10-23

    Solar devices based on semiconductor nanoparticles require the use of conductive ligands; however, replacing the native, insulating ligands with conductive metal chalcogenide complexes introduces structural defects within the crystalline nanostructure that act as traps for charge carriers. We utilized atomically thin semiconductor nanoplatelets as a convenient platform for studying, both microscopically and spectroscopically, the development of defects during ligand exchange with the conductive ligands Na 4 SnS 4 and (NH 4 ) 4 Sn 2 S 6 . These defects can be repaired via mild chemical or thermal routes, through the addition of L-type ligands or wet annealing, respectively. This results in a higher-quality, conductive, colloidally stable nanomaterial that may be used as the active film in optoelectronic devices. © 2017 The Authors. Published by Wiley-VCH Verlag GmbH & Co. KGaA.

  11. Reward optimization of a repairable system

    Energy Technology Data Exchange (ETDEWEB)

    Castro, I.T. [Departamento de Matematicas, Facultad de Veterinaria, Universidad de Extremadura, Avenida de la Universidad, s/n. 10071 Caceres (Spain)]. E-mail: inmatorres@unex.es; Perez-Ocon, R. [Departamento de Estadistica e Investigacion Operativa, Facultad de Ciencias, Universidad de Granada, Avenida de Severo Ochoa, s/n. 18071 Granada (Spain)]. E-mail: rperezo@ugr.es

    2006-03-15

    This paper analyzes a system subject to repairable and non-repairable failures. Non-repairable failures lead to replacement of the system. Repairable failures, first lead to repair but they lead to replacement after a fixed number of repairs. Operating and repair times follow phase type distributions (PH-distributions) and the pattern of the operating times is modelled by a geometric process. In this context, the problem is to find the optimal number of repairs, which maximizes the long-run average reward per unit time. To this end, the optimal number is determined and it is obtained by efficient numerical procedures.

  12. Reward optimization of a repairable system

    International Nuclear Information System (INIS)

    Castro, I.T.; Perez-Ocon, R.

    2006-01-01

    This paper analyzes a system subject to repairable and non-repairable failures. Non-repairable failures lead to replacement of the system. Repairable failures, first lead to repair but they lead to replacement after a fixed number of repairs. Operating and repair times follow phase type distributions (PH-distributions) and the pattern of the operating times is modelled by a geometric process. In this context, the problem is to find the optimal number of repairs, which maximizes the long-run average reward per unit time. To this end, the optimal number is determined and it is obtained by efficient numerical procedures

  13. Botulinum toxin is detrimental to repair of a chronic rotator cuff tear in a rabbit model.

    Science.gov (United States)

    Gilotra, Mohit; Nguyen, Thao; Christian, Matthew; Davis, Derik; Henn, R Frank; Hasan, Syed Ashfaq

    2015-08-01

    Re-tear continues to be a problem after rotator cuff repair. Intramuscular botulinum toxin (Botox) injection can help optimize tension at the repair site to promote healing but could have an adverse effect on the degenerated muscle in a chronic tear. We hypothesized that Botox injection would improve repair characteristics without adverse effect on the muscle in a chronic rotator cuff tear model. The supraspinatus tendon of both shoulders in 14 rabbits underwent delayed repair 12 weeks after transection. One shoulder was treated with intramuscular Botox injection and the other with a saline control injection. Six weeks after repair, outcomes were based on biomechanics, histology, and magnetic resonance imaging. Botox-treated repairs were significantly weaker (2.64 N) than control repairs (5.51 N, p = 0.03). Eighty percent of Botox-treated repairs and 40% of control repairs healed with some partial defect. Fatty infiltration of the supraspinatus was present in all shoulders (Goutallier Grade 3 or 4) but was increased in the setting of Botox. This study provides additional support for the rabbit supraspinatus model of chronic cuff tear, showing consistent fatty infiltration. Contrary to our hypothesis, Botox had a negative effect on repair strength and might increase fatty infiltration. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  14. Tissue repair capacity and repair kinetics deduced from multifractionated or continuous irradiation regimens with incomplete repair

    International Nuclear Information System (INIS)

    Thames, H.D. Jr.; Peters, L.J.

    1984-01-01

    A model is proposed for cell survival after multiple doses, when the interfraction interval is insufficient for complete Elkind repair. In the limit of ever-increasing number of ever-smaller fractional doses, the model transforms into the accumulation model of survival after continuous irradiation. When adapted to describe tissue responses to isoeffective multifractionated regimens, wherein repair is incomplete, a generalization of the usually linear plot of reciprocal total dose versus dose per fraction is obtained, in which downward curvature is evident. There is an advantage in studying tissue responses to multifractionated regimens with incomplete repair in the interfraction intervals, or continuous exposures at various dose rates since, in addition to determination of repair capacity, there is an estimate of repair kinetics. Results of analyses of previously published data are presented as illustration. Estimated from the response of three acutely responding normal tissues in the mouse (jejunum, colon and bone marrow), repair halftimes ranged from 0.3-0.9 h and values of β/delta were approximately 0.1 Gy -1 . From the response of mouse lung (LD50 for pneumonitis) to multifractionated regimens with incomplete repair, the repair halftime was estimated at 1.5 h and β/delta was 0.27 Gy -1 . In the rat spinal cord β/delta was 0.7 Gy -1 and Tsub(1/2) was 1.5 h. (U.K.)

  15. Residual stress by repair welds

    International Nuclear Information System (INIS)

    Mochizuki, Masahito; Toyoda, Masao

    2003-01-01

    Residual stress by repair welds is computed using the thermal elastic-plastic analysis with phase-transformation effect. Coupling phenomena of temperature, microstructure, and stress-strain fields are simulated in the finite-element analysis. Weld bond of a plate butt-welded joint is gouged and then deposited by weld metal in repair process. Heat source is synchronously moved with the deposition of the finite-element as the weld deposition. Microstructure is considered by using CCT diagram and the transformation behavior in the repair weld is also simulated. The effects of initial stress, heat input, and weld length on residual stress distribution are studied from the organic results of numerical analysis. Initial residual stress before repair weld has no influence on the residual stress after repair treatment near weld metal, because the initial stress near weld metal releases due to high temperature of repair weld and then stress by repair weld regenerates. Heat input has an effect for residual stress distribution, for not its magnitude but distribution zone. Weld length should be considered reducing the magnitude of residual stress in the edge of weld bead; short bead induces high tensile residual stress. (author)

  16. Monogenic diseases of DNA repair

    DEFF Research Database (Denmark)

    Keijzers, Guido; Bakula, Daniela; Scheibye-Knudsen, Morten

    2017-01-01

    Maintaining the stability of the genome is essential for all organisms, and it is not surprising that damage to DNA has been proposed as an explanation for multiple chronic diseases.1-5 Conserving a pristine genome is therefore of central importance to our health. To overcome the genotoxic stress...... of a growing number of human diseases. Notably, many of these monogenic DNA-repair disorders display features of accelerated aging, supporting the notion that genome maintenance is a key factor for organismal longevity. This review focuses on the physiological consequences of loss of DNA repair, particularly...... in the context of monogenic DNA-repair diseases....

  17. Repairing and Upgrading Your PC

    CERN Document Server

    Thompson, Robert

    2009-01-01

    Repairing and Upgrading Your PC delivers start-to-finish instructions, simple enough for even the most inexperienced PC owner, for troubleshooting, repairing, and upgrading your computer. Written by hardware experts Robert Bruce Thompson and Barbara Fritchman Thompson, this book covers it all: how to troubleshoot a troublesome PC, how to identify which components make sense for an upgrade, and how to tear it all down and put it back together. This book shows how to repair and upgrade all of your PC's essential components.

  18. 40 CFR 798.5500 - Differential growth inhibition of repair proficient and repair deficient bacteria: “Bacterial DNA...

    Science.gov (United States)

    2010-07-01

    ... repair proficient and repair deficient bacteria: âBacterial DNA damage or repair tests.â 798.5500 Section... inhibition of repair proficient and repair deficient bacteria: “Bacterial DNA damage or repair tests.” (a... killing or growth inhibition of repair deficient bacteria in a set of repair proficient and deficient...

  19. Preclinical Studies for Cartilage Repair

    Science.gov (United States)

    Hurtig, Mark B.; Buschmann, Michael D.; Fortier, Lisa A.; Hoemann, Caroline D.; Hunziker, Ernst B.; Jurvelin, Jukka S.; Mainil-Varlet, Pierre; McIlwraith, C. Wayne; Sah, Robert L.; Whiteside, Robert A.

    2011-01-01

    Investigational devices for articular cartilage repair or replacement are considered to be significant risk devices by regulatory bodies. Therefore animal models are needed to provide proof of efficacy and safety prior to clinical testing. The financial commitment and regulatory steps needed to bring a new technology to clinical use can be major obstacles, so the implementation of highly predictive animal models is a pressing issue. Until recently, a reductionist approach using acute chondral defects in immature laboratory species, particularly the rabbit, was considered adequate; however, if successful and timely translation from animal models to regulatory approval and clinical use is the goal, a step-wise development using laboratory animals for screening and early development work followed by larger species such as the goat, sheep and horse for late development and pivotal studies is recommended. Such animals must have fully organized and mature cartilage. Both acute and chronic chondral defects can be used but the later are more like the lesions found in patients and may be more predictive. Quantitative and qualitative outcome measures such as macroscopic appearance, histology, biochemistry, functional imaging, and biomechanical testing of cartilage, provide reliable data to support investment decisions and subsequent applications to regulatory bodies for clinical trials. No one model or species can be considered ideal for pivotal studies, but the larger animal species are recommended for pivotal studies. Larger species such as the horse, goat and pig also allow arthroscopic delivery, and press-fit or sutured implant fixation in thick cartilage as well as second look arthroscopies and biopsy procedures. PMID:26069576

  20. Panoramic optical-servoing for industrial inspection and repair

    Science.gov (United States)

    Sallinger, Christian; O'Leary, Paul; Retschnig, Alexander; Kammerhofer, Martin

    2004-05-01

    Recently specialized robots were introduced to perform the task of inspection and repair in large cylindrical structures such as ladles, melting furnaces and converters. This paper reports on the image processing system and optical servoing for one such a robot. A panoramic image of the vessels inner surface is produced by performing a coordinated robot motion and image acquisition. The level of projective distortion is minimized by acquiring a high density of images. Normalized phase correlation calculated via the 2D Fourier transform is used to calculate the shift between the single images. The narrow strips from the dense image map are then stitched together to build the panorama. The mapping between the panoramic image and the positioning of the robot is established during the stitching of the images. This enables optical feedback. The robots operator can locate a defect on the surface by selecting the area of the image. Calculation of the forward and inverse kinematics enable the robot to automatically move to the location on the surface requiring repair. Experimental results using a standard 6R industrial robot have shown the full functionality of the system concept. Finally, were test measurements carried out successfully, in a ladle at a temperature of 1100° C.

  1. Innovative repair of subsidence damage

    International Nuclear Information System (INIS)

    Marino, G.G.

    1992-01-01

    In order to improve handling of subsidence damages the Illinois Mine Subsidence Insurance Fund supported the development of novel cost-effective methods of repair. The research in developing the repairs was directed towards the most common and costly damages that had been observed. As a result repair techniques were designed for structurally cracked foundations in the tension zone; structurally cracked foundations in the compression zone; and damaged or undamaged tilted foundations. When appropriate the postulated methods would result in: 1. significant cost savings (over conventional procedures); 2. a structural capacity greater than when the foundation was uncracked; and 3. an aesthetic appeal. All the postulated repair methodologies were laboratory and/or field tested. This paper will summarize the essentials of each technique developed and the test results

  2. Mammalian DNA Repair. Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Wood, Richard D.

    2003-01-24

    The Gordon Research Conference (GRC) on Mammalian DNA Repair was held at Harbortown Resort, Ventura Beach, CA. Emphasis was placed on current unpublished research and discussion of the future target areas in this field.

  3. Canadian company innovates dam repair

    International Nuclear Information System (INIS)

    Anon.

    2000-01-01

    Successful repair without any downtime, of the Sabana Yegua power and irrigation structure in the western Dominican Republic by Aquatic Sciences Ltd., a St. Catherine, Ontario-based underwater specialist company, is discussed. The structure was damaged by Hurricane George last when when rising water levels damaged a major valve in the control gate chamber. The repair strategy designed by Aquatic Sciences used a remotely operated vehicle with a mechanical arm for minor tasks which placed a specially-made plug into the inlet pipe. The work was completed in one week, saving the utility company a great deal of money by making it possible to make the repairs remotely in the gate chamber without having to drain the tunnel, as would have been necessary had the repair been completed manually. The remotely operated vehicles use a scanning sonar as well as light to find their way. They are particularly well adapted to work underwater under low-visibility conditions

  4. Betonreparationers holdbarhed (Durability of Concrete Repairs)

    DEFF Research Database (Denmark)

    Brimnes, Eydbjørn; Dali, Bogi í; Larsen, Erik Stoklund

    1999-01-01

    Concrete repairs on 11 pillars on bridges built in the sixties and repaired 8 to 9 years ago have been examined. Especially the chloride penetration in the repair concrete have been measured. Chloride penetration in the repair concrete is much lower than in the original concrete....

  5. 40 CFR 63.1005 - Leak repair.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Leak repair. 63.1005 Section 63.1005... Standards for Equipment Leaks-Control Level 1 § 63.1005 Leak repair. (a) Leak repair schedule. The owner or operator shall repair each leak detected no later than 15 calendar days after it is detected, except as...

  6. 40 CFR 63.1024 - Leak repair.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Leak repair. 63.1024 Section 63.1024... Standards for Equipment Leaks-Control Level 2 Standards § 63.1024 Leak repair. (a) Leak repair schedule. The owner or operator shall repair each leak detected as soon as practical, but not later than 15 calendar...

  7. 40 CFR 65.105 - Leak repair.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 15 2010-07-01 2010-07-01 false Leak repair. 65.105 Section 65.105... FEDERAL AIR RULE Equipment Leaks § 65.105 Leak repair. (a) Leak repair schedule. The owner or operator shall repair each leak detected as soon as practical but not later than 15 calendar days after it is...

  8. Laparoscopic Repair of Inguinal Hernias

    OpenAIRE

    Carter, Jonathan; Duh, Quan-Yang

    2011-01-01

    For patients with recurrent inguinal hernia, or bilateral inguinal hernia, or for women, laparoscopic repair offers significant advantages over open techniques with regard to recurrence risk, pain, and recovery. For unilateral first-time hernias, either laparoscopic or open repair with mesh can offer excellent results. The major drawback of laparoscopy is that the technique requires a significant number of cases to master. For surgeons in group practice, it makes sense to have one surgeon in ...

  9. Repair Types, Procedures - Part 1

    Science.gov (United States)

    2010-05-01

    Affordable Combat Aircraft, AGARD - CP -600, 1997. [17] Helbling J, Grover R and Ratwani M. M “Analysis and Structural Test of Composite Reinforcement to...considered suitable for the composite patch repair of aluminum structure. Ductile adhesives such as FM- 73 are preferred over brittle adhesives Repair Types...zone. A proper cure cycle is followed as prescribed by the adhesive manufacturer. For FM- 73 adhesive cure at 2500F (1210C) for 120 minutes is

  10. Laparoscopic repair of postoperative perineal hernia.

    LENUS (Irish Health Repository)

    Ryan, Stephen

    2010-01-01

    Perineal hernias are infrequent complications following abdominoperineal operations. Various approaches have been described for repair of perineal hernias including open transabdominal, transperineal or combined abdominoperineal repairs. The use of laparoscopic transabdominal repair of perineal hernias is not well-described. We present a case report demonstrating the benefits of laparoscopic repair of perineal hernia following previous laparoscopic abdominoperineal resection (APR) using a nonabsorbable mesh to repair the defect. We have demonstrated that the use of laparoscopy with repair of the pelvic floor defect using a non absorbable synthetic mesh offers an excellent alternative with many potential advantages over open transabdominal and transperineal repairs.

  11. Overlapping sphincteroplasty and posterior repair.

    Science.gov (United States)

    Crane, Andrea K; Myers, Erinn M; Lippmann, Quinn K; Matthews, Catherine A

    2014-12-01

    Knowledge of how to anatomically reconstruct extensive posterior-compartment defects is variable among gynecologists. The objective of this video is to demonstrate an effective technique of overlapping sphincteroplasty and posterior repair. In this video, a scripted storyboard was constructed that outlines the key surgical steps of a comprehensive posterior compartment repair: (1) surgical incision that permits access to posterior compartment and perineal body, (2) dissection of the rectovaginal space up to the level of the cervix, (3) plication of the rectovaginal muscularis, (4) repair of internal and external anal sphincters, and (5) reconstruction of the perineal body. Using a combination of graphic illustrations and live video footage, tips on repair are highlighted. The goals at the end of repair are to: (1) have improved vaginal caliber, (2) increase rectal tone along the entire posterior vaginal wall, (3) have the posterior vaginal wall at a perpendicular plane to the perineal body, (4) reform the hymenal ring, and (5) not have an overly elongated perineal body. This video provides a step-by-step guide on how to perform an overlapping sphincteroplasty and posterior repair.

  12. Scarf Repair of Composite Laminates

    Directory of Open Access Journals (Sweden)

    Xie Zonghong

    2016-01-01

    Full Text Available The use of composite materials, such as carbon-fiber reinforced plastic (CFRP composites, aero-structures has led to an increased need of advanced assembly joining and repair technologies. Adhesive bonded repairs as an alternative to recover full or part of initial strength were investigated. Tests were conducted with the objective of evaluating the effectiveness of techniques used for repairing damage fiber reinforced laminated composites. Failure loads and failure modes were generated and compared with the following parameters: scarf angles, roughness of grind tool and number of external plies. Results showed that scarf angle was the critical parameter and the largest tensile strength was observed with the smallest scarf angle. Besides, the use of external plies at the outer surface could not increase the repairs efficiency for large scarf angle. Preparing the repair surfaces by sanding them with a sander ranging from 60 to 100 grit number had significant effect on the failure load. These results allowed the proposal of design principles for repairing CFRP structures.

  13. Early postoperative repair status after rotator cuff repair cannot be accurately classified using questionnaires of patient function and isokinetic strength evaluation.

    Science.gov (United States)

    Colliver, Jessica; Wang, Allan; Joss, Brendan; Ebert, Jay; Koh, Eamon; Breidahl, William; Ackland, Timothy

    2016-04-01

    This study investigated if patients with an intact tendon repair or partial-thickness retear early after rotator cuff repair display differences in clinical evaluations and whether early tendon healing can be predicted using these assessments. We prospectively evaluated 60 patients at 16 weeks after arthroscopic supraspinatus repair. Evaluation included the Oxford Shoulder Score, 11-item version of the Disabilities of the Arm, Shoulder and Hand, visual analog scale for pain, 12-item Short Form Health Survey, isokinetic strength, and magnetic resonance imaging (MRI). Independent t tests investigated clinical differences in patients based on the Sugaya MRI rotator cuff classification system (grades 1, 2, or 3). Discriminant analysis determined whether intact repairs (Sugaya grade 1) and partial-thickness retears (Sugaya grades 2 and 3) could be predicted. No differences (P repair was intact. The ability to discriminate between groups was enhanced with up to 5 variables entered; however, only 87% of the partial-retear group and 36% of the intact-repair group were correctly classified. No differences in clinical scores existed between patients stratified by the Sugaya MRI classification system at 16 weeks. An intact repair or partial-thickness retear could not be accurately predicted. Our results suggest that correct classification of healing in the early postoperative stages should involve imaging. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  14. Aging and DNA repair capability. [Review

    Energy Technology Data Exchange (ETDEWEB)

    Tice, R R

    1977-01-01

    A review of the literature on DNA repair processes in relation to aging is presented under the following headings: DNA repair processes; age-related occurrence of unrepaired DNA lesions; DNA repair capability as a function of age; tissue-specific DNA repair capability; acceleration of the aging process by exposure to DNA damaging agents; human genetic syndromes; and longevity and DNA repair processes. (HLW)

  15. Cartilage Repair Surgery: Outcome Evaluation by Using Noninvasive Cartilage Biomarkers Based on Quantitative MRI Techniques?

    Science.gov (United States)

    Jungmann, Pia M.; Baum, Thomas; Bauer, Jan S.; Karampinos, Dimitrios C.; Link, Thomas M.; Li, Xiaojuan; Trattnig, Siegfried; Rummeny, Ernst J.; Woertler, Klaus; Welsch, Goetz H.

    2014-01-01

    Background. New quantitative magnetic resonance imaging (MRI) techniques are increasingly applied as outcome measures after cartilage repair. Objective. To review the current literature on the use of quantitative MRI biomarkers for evaluation of cartilage repair at the knee and ankle. Methods. Using PubMed literature research, studies on biochemical, quantitative MR imaging of cartilage repair were identified and reviewed. Results. Quantitative MR biomarkers detect early degeneration of articular cartilage, mainly represented by an increasing water content, collagen disruption, and proteoglycan loss. Recently, feasibility of biochemical MR imaging of cartilage repair tissue and surrounding cartilage was demonstrated. Ultrastructural properties of the tissue after different repair procedures resulted in differences in imaging characteristics. T2 mapping, T1rho mapping, delayed gadolinium-enhanced MRI of cartilage (dGEMRIC), and diffusion weighted imaging (DWI) are applicable on most clinical 1.5 T and 3 T MR scanners. Currently, a standard of reference is difficult to define and knowledge is limited concerning correlation of clinical and MR findings. The lack of histological correlations complicates the identification of the exact tissue composition. Conclusions. A multimodal approach combining several quantitative MRI techniques in addition to morphological and clinical evaluation might be promising. Further investigations are required to demonstrate the potential for outcome evaluation after cartilage repair. PMID:24877139

  16. Cartilage Repair Surgery: Outcome Evaluation by Using Noninvasive Cartilage Biomarkers Based on Quantitative MRI Techniques?

    Directory of Open Access Journals (Sweden)

    Pia M. Jungmann

    2014-01-01

    Full Text Available Background. New quantitative magnetic resonance imaging (MRI techniques are increasingly applied as outcome measures after cartilage repair. Objective. To review the current literature on the use of quantitative MRI biomarkers for evaluation of cartilage repair at the knee and ankle. Methods. Using PubMed literature research, studies on biochemical, quantitative MR imaging of cartilage repair were identified and reviewed. Results. Quantitative MR biomarkers detect early degeneration of articular cartilage, mainly represented by an increasing water content, collagen disruption, and proteoglycan loss. Recently, feasibility of biochemical MR imaging of cartilage repair tissue and surrounding cartilage was demonstrated. Ultrastructural properties of the tissue after different repair procedures resulted in differences in imaging characteristics. T2 mapping, T1rho mapping, delayed gadolinium-enhanced MRI of cartilage (dGEMRIC, and diffusion weighted imaging (DWI are applicable on most clinical 1.5 T and 3 T MR scanners. Currently, a standard of reference is difficult to define and knowledge is limited concerning correlation of clinical and MR findings. The lack of histological correlations complicates the identification of the exact tissue composition. Conclusions. A multimodal approach combining several quantitative MRI techniques in addition to morphological and clinical evaluation might be promising. Further investigations are required to demonstrate the potential for outcome evaluation after cartilage repair.

  17. Electrically Mediated Trauma Repair

    Science.gov (United States)

    1994-07-07

    potential (TEP) (Johnston and Hoshiko, 1971; Rick et al., 1988; Shi and Borgens, 1994). In the axolotl neurulae, a gradient of 10 - 20 mV/mm is...reach 60-80 mV/mm. A more shallow voltage gradient is observed in the transverse plane of axolotl neurulae associated with mirror image outwardly

  18. Predictive factors for cerebrovascular accidents after thoracic endovascular aortic repair.

    Science.gov (United States)

    Mariscalco, Giovanni; Piffaretti, Gabriele; Tozzi, Matteo; Bacuzzi, Alessandro; Carrafiello, Giampaolo; Sala, Andrea; Castelli, Patrizio

    2009-12-01

    Cerebrovascular accidents are devastating and worrisome complications after thoracic endovascular aortic repair. The aim of this study was to determine cerebrovascular accident predictors after thoracic endovascular aortic repair. Between January 2001 and June 2008, 76 patients treated with thoracic endovascular aortic repair were prospectively enrolled. The study cohort included 61 men; mean age was 65.4 +/- 16.8 years. All patients underwent a specific neurologic assessment on an hourly basis postoperatively to detect neurologic deficits. Cerebrovascular accidents were diagnosed on the basis of physical examination, tomography scan or magnetic resonance imaging, or autopsy. Cerebrovascular accidents occurred in 8 (10.5%) patients, including 4 transient ischemic attack and 4 major strokes. Four cases were observed within the first 24-hours. Multivariable analysis revealed that anatomic incompleteness of the Willis circle (odds ratio [OR] 17.19, 95% confidence interval [CI] 2.10 to 140.66), as well as the presence of coronary artery disease (OR 6.86, 95 CI% 1.18 to 40.05), were independently associated with postoperative cerebrovascular accident development. Overall hospital mortality was 9.2%, with no significant difference for patients hit by cerebrovascular accidents (25.0% vs 7.3%, p = 0.102). Preexisting coronary artery disease, reflecting a severe diseased aorta and anomalies of Willis circle are independent cerebrovascular accident predictors after thoracic endovascular aortic repair procedures. A careful evaluation of the arch vessels and cerebral vascularization should be mandatory for patients suitable for thoracic endovascular aortic repair.

  19. [Biomarkers of radiation-induced DNA repair processes].

    Science.gov (United States)

    Vallard, Alexis; Rancoule, Chloé; Guy, Jean-Baptiste; Espenel, Sophie; Sauvaigo, Sylvie; Rodriguez-Lafrasse, Claire; Magné, Nicolas

    2017-11-01

    The identification of DNA repair biomarkers is of paramount importance. Indeed, it is the first step in the process of modulating radiosensitivity and radioresistance. Unlike tools of detection and measurement of DNA damage, DNA repair biomarkers highlight the variations of DNA damage responses, depending on the dose and the dose rate. The aim of the present review is to describe the main biomarkers of radiation-induced DNA repair. We will focus on double strand breaks (DSB), because of their major role in radiation-induced cell death. The most important DNA repair biomarkers are DNA damage signaling proteins, with ATM, DNA-PKcs, 53BP1 and γ-H2AX. They can be analyzed either using immunostaining, or using lived cell imaging. However, to date, these techniques are still time and money consuming. The development of "omics" technologies should lead the way to new (and usable in daily routine) DNA repair biomarkers. Copyright © 2017 Société Française du Cancer. Published by Elsevier Masson SAS. All rights reserved.

  20. Thermal segregation of asphalt material in road repair

    Directory of Open Access Journals (Sweden)

    Juliana Byzyka

    2017-08-01

    Full Text Available This paper presents results from a field study of asphaltic pavement patching operations performed by three different contractors working in a total of ten sites. It forms part of an ongoing research programme towards improving the performance of pothole repairs. Thermal imaging technology was used to record temperatures of the patching material throughout the entire exercise, from the stage of material collection, through transportation to repair site, patch forming, and compaction. Practical complications occurring during patch repairs were also identified. It was found that depending on the weather conditions, duration of the travel and poor insulation of the transported hot asphalt mix, its temperature can drop as high as 116.6 °C over the period that the reinstatement team travel to the site and prepare the patch. This impacting is on the durability and performance of the executed repairs. Cold spots on the asphalt mat and temperature differentials between the new hot-fill asphalt mix and existing pavement were also identified as poorly compacted areas that were prone to premature failure. For example, over the five-minute period, the temperature at one point reduced by 33% whereas the temperatures of nearby areas decreased by 65% and 71%. A return visit to the repair sites, three months later, revealed that locations where thermal segregation was noted, during the patching operation, had failed prematurely.

  1. 49 CFR 1242.42 - Administration, repair and maintenance, machinery repair, equipment damaged, dismantling retired...

    Science.gov (United States)

    2010-10-01

    ... repair, equipment damaged, dismantling retired property, fringe benefits, other casualties and insurance, lease rentals, joint facility rents, other rents, depreciation, joint facility, repairs billed to others... maintenance, machinery repair, equipment damaged, dismantling retired property, fringe benefits, other...

  2. Simulation based mask defect repair verification and disposition

    Science.gov (United States)

    Guo, Eric; Zhao, Shirley; Zhang, Skin; Qian, Sandy; Cheng, Guojie; Vikram, Abhishek; Li, Ling; Chen, Ye; Hsiang, Chingyun; Zhang, Gary; Su, Bo

    2009-10-01

    As the industry moves towards sub-65nm technology nodes, the mask inspection, with increased sensitivity and shrinking critical defect size, catches more and more nuisance and false defects. Increased defect counts pose great challenges in the post inspection defect classification and disposition: which defect is real defect, and among the real defects, which defect should be repaired and how to verify the post-repair defects. In this paper, we address the challenges in mask defect verification and disposition, in particular, in post repair defect verification by an efficient methodology, using SEM mask defect images, and optical inspection mask defects images (only for verification of phase and transmission related defects). We will demonstrate the flow using programmed mask defects in sub-65nm technology node design. In total 20 types of defects were designed including defects found in typical real circuit environments with 30 different sizes designed for each type. The SEM image was taken for each programmed defect after the test mask was made. Selected defects were repaired and SEM images from the test mask were taken again. Wafers were printed with the test mask before and after repair as defect printability references. A software tool SMDD-Simulation based Mask Defect Disposition-has been used in this study. The software is used to extract edges from the mask SEM images and convert them into polygons to save in GDSII format. Then, the converted polygons from the SEM images were filled with the correct tone to form mask patterns and were merged back into the original GDSII design file. This merge is for the purpose of contour simulation-since normally the SEM images cover only small area (~1 μm) and accurate simulation requires including larger area of optical proximity effect. With lithography process model, the resist contour of area of interest (AOI-the area surrounding a mask defect) can be simulated. If such complicated model is not available, a simple

  3. Reprogramming Cells for Brain Repair

    Directory of Open Access Journals (Sweden)

    Randall D. McKinnon

    2013-08-01

    Full Text Available At present there are no clinical therapies that can repair traumatic brain injury, spinal cord injury or degenerative brain disease. While redundancy and rewiring of surviving circuits can recover some lost function, the brain and spinal column lack sufficient endogenous stem cells to replace lost neurons or their supporting glia. In contrast, pre-clinical studies have demonstrated that exogenous transplants can have remarkable efficacy for brain repair in animal models. Mesenchymal stromal cells (MSCs can provide paracrine factors that repair damage caused by ischemic injury, and oligodendrocyte progenitor cell (OPC grafts give dramatic functional recovery from spinal cord injury. These studies have progressed to clinical trials, including human embryonic stem cell (hESC-derived OPCs for spinal cord repair. However, ESC-derived allografts are less than optimal, and we need to identify a more appropriate donor graft population. The cell reprogramming field has developed the ability to trans-differentiate somatic cells into distinct cell types, a technology that has the potential to generate autologous neurons and glia which address the histocompatibility concerns of allografts and the tumorigenicity concerns of ESC-derived grafts. Further clarifying how cell reprogramming works may lead to more efficient direct reprogram approaches, and possibly in vivo reprogramming, in order to promote brain and spinal cord repair.

  4. Sports hernia repair with adductor tenotomy.

    Science.gov (United States)

    Harr, J N; Brody, F

    2017-02-01

    Sports hernias, or athletic pubalgia, is common in athletes, and primarily involves injury to the fascia, muscles, and tendons of the inguinal region near their insertion onto the pubic bone. However, management varies widely, and rectus and adductor tenotomies have not been adequately described. The purpose of this manuscript is to demonstrate a suture repair and a rectus and adductor longus tenotomy technique for sports hernias. After magnetic-resonance-imaging confirmation of sports hernias with rectus and adductor tendonitis, 22 patients underwent a suture herniorrhaphy with adductor tenotomy. The procedure is performed through a 4-cm incision, and a fascial release of the rectus abdominis and adductor tenotomy is performed to relieve the opposing vector forces on the pubic bone. All 22 patients returned to their respective sports and regained their ability to perform at a high level, including professional status. No further surgery was required. In athletes with MRI confirmation of rectus and adductor longus injuries, tenotomies along with a herniorraphy may improve outcomes. A suture repair to reinforce the inguinal floor prevents mesh-related complications, especially in young athletes.

  5. MRI of menisci repaired with bioabsorbable arrows

    International Nuclear Information System (INIS)

    Mustonen, Antti O.T.; Kiuru, Martti; Koskinen, Seppo K.; Tielinen, Laura; Lindahl, Jan; Hirvensalo, Eero

    2006-01-01

    To analyze with conventional magnetic resonance imaging (MRI) the signal appearance of menisci repaired with bioabsorbable arrows. Forty-four patients with 47 meniscal tears treated with bioabsorbable arrows underwent follow-up conventional MRI examination. The time interval between the surgery and MRI varied from 5 to 67 months (mean 26 months). Twenty-six patients also had concurrent repair of torn anterior cruciate ligament. The following grades were used to classify meniscal signal intensity: (a) G0; low signal intensity on all sequences and regular configuration in every plane, (b) G1; increased signal intensity within the meniscus, not extending to the meniscal surface, (c) G2; increased signal intensity linear in shape, which may or may not communicate with the capsular margin of the meniscus, without extending to the meniscal surface, and (d) G3; increased signal intensity extending to the meniscal surface. Thirteen menisci (27.5%) had normal signal intensity, 13 menisci (27.5%) Grade 1 signal intensity, 9 menisci (19%) Grade 2 signal intensity and 12 menisci (26%) Grade 3 signal intensity. The time difference between operation and MRI was statistically significant between the G0 (36 months) and G3 groups (14 months; P=0.0288). There was no statistical significance in different grades between medial and lateral meniscus or between patients with operated or intact ACL. On physical examination sixteen patients reported slight symptoms, seen evenly in each group. (orig.)

  6. DNA repair in PHA stimulated human lymphocytes

    International Nuclear Information System (INIS)

    Catena, C.; Mattoni, A.

    1984-01-01

    Damage an repair of radiation induced DNA strand breaks were measured by alkaline lysis and hydroxyapatite chromatography. PHA stimulated human lymphocytes show that the rejoining process is complete within the first 50 min., afterwords secondary DNA damage and chromatid aberration. DNA repair, in synchronized culture, allows to evaluate individual repair capacity and this in turn can contribute to the discovery of individual who, although they do not demonstrate apparent clinical signs, are carriers of DNA repair deficiency. Being evident that a correlation exists between DNA repair capacity and carcinogenesis, the possibility of evaluating the existent relationship between DNA repair and survival in tumor cells comes therefore into discussion

  7. Role of DNA repair in repair of cytogenetic damages. Contribution of repair of single-strand DNA breaks to cytogenetic damages repair

    International Nuclear Information System (INIS)

    Rozanova, O.M.; Zaichkina, S.I.; Aptikaev, G.F.; Ganassi, E.Eh.

    1989-01-01

    The comparison was made between the results of the effect of poly(ADP-ribosylation) ingibitors (e.g. nicotinamide and 3-aminobenzamide) and a chromatin proteinase ingibitor, phenylmethylsulfonylfluoride, on the cytogenetic damages repair, by a micronuclear test, and DNA repair in Chinese hamster fibroblasts. The values of the repair half-periods (5-7 min for the cytogenetic damages and 5 min for the rapidly repaired DNA damages) and a similar modyfying effect with regard to radiation cytogenetic damages and kynetics of DNA damages repair were found to be close. This confirms the contribution of repair of DNA single-strand breaks in the initiation of structural damages to chromosomes

  8. Incore inspection and repairing device

    International Nuclear Information System (INIS)

    Ito, Arata; Kimura, Motohiko

    1998-01-01

    The present invention provides a device for inspecting and repairing the inside of a reactor container even if it is narrow, with no trouble by using a swimming-type operation robot. Namely, the device of the present invention conducts inspection and repairing operations for the inside of the reactor by introducing a swimming type operation robot into the reactor container. The swimming-type operation robot comprises a robot main body having a propeller, a balancer operably disposed to the robot main body and an inspection and repairing unit attached detachable to the balancer. In the device of the present invention, since the inspection and preparing unit is attached detachably to the swimming robot, a robot which transports tools is formed as a standard product. As a result, the production cost can be reduced, and the reliability of products can be improved. Appropriate operations can be conducted by using best tools. (I.S.)

  9. Mitochondrial DNA repair and aging

    International Nuclear Information System (INIS)

    Mandavilli, Bhaskar S.; Santos, Janine H.; Van Houten, Bennett

    2002-01-01

    The mitochondrial electron transport chain plays an important role in energy production in aerobic organisms and is also a significant source of reactive oxygen species that damage DNA, RNA and proteins in the cell. Oxidative damage to the mitochondrial DNA is implicated in various degenerative diseases, cancer and aging. The importance of mitochondrial ROS in age-related degenerative diseases is further strengthened by studies using animal models, Caenorhabditis elegans, Drosophila and yeast. Research in the last several years shows that mitochondrial DNA is more susceptible to various carcinogens and ROS when compared to nuclear DNA. DNA damage in mammalian mitochondria is repaired by base excision repair (BER). Studies have shown that mitochondria contain all the enzymes required for BER. Mitochondrial DNA damage, if not repaired, leads to disruption of electron transport chain and production of more ROS. This vicious cycle of ROS production and mtDNA damage ultimately leads to energy depletion in the cell and apoptosis

  10. Mitochondrial DNA repair and aging

    Energy Technology Data Exchange (ETDEWEB)

    Mandavilli, Bhaskar S.; Santos, Janine H.; Van Houten, Bennett

    2002-11-30

    The mitochondrial electron transport chain plays an important role in energy production in aerobic organisms and is also a significant source of reactive oxygen species that damage DNA, RNA and proteins in the cell. Oxidative damage to the mitochondrial DNA is implicated in various degenerative diseases, cancer and aging. The importance of mitochondrial ROS in age-related degenerative diseases is further strengthened by studies using animal models, Caenorhabditis elegans, Drosophila and yeast. Research in the last several years shows that mitochondrial DNA is more susceptible to various carcinogens and ROS when compared to nuclear DNA. DNA damage in mammalian mitochondria is repaired by base excision repair (BER). Studies have shown that mitochondria contain all the enzymes required for BER. Mitochondrial DNA damage, if not repaired, leads to disruption of electron transport chain and production of more ROS. This vicious cycle of ROS production and mtDNA damage ultimately leads to energy depletion in the cell and apoptosis.

  11. Primary unilateral cleft lip repair

    OpenAIRE

    Adenwalla, H. S.; Narayanan, P. V.

    2009-01-01

    The unilateral cleft lip is a complex deformity. Surgical correction has evolved from a straight repair through triangular and quadrilateral repairs to the Rotation Advancement Technique of Millard. The latter is the technique followed at our centre for all unilateral cleft lip patients. We operate on these at five to six months of age, do not use pre-surgical orthodontics, and follow a protocol to produce a notch-free vermillion. This is easy to follow even for trainees. We also perform clos...

  12. Advanced repair solution of clear defects on HTPSM by using nanomachining tool

    Science.gov (United States)

    Lee, Hyemi; Kim, Munsik; Jung, Hoyong; Kim, Sangpyo; Yim, Donggyu

    2015-10-01

    As the mask specifications become tighter for low k1 lithography, more aggressive repair accuracy is required below sub 20nm tech. node. To meet tight defect specifications, many maskshops select effective repair tools according to defect types. Normally, pattern defects are repaired by the e-beam repair tool and soft defects such as particles are repaired by the nanomachining tool. It is difficult for an e-beam repair tool to remove particle defects because it uses chemical reaction between gas and electron, and a nanomachining tool, which uses physical reaction between a nano-tip and defects, cannot be applied for repairing clear defects. Generally, film deposition process is widely used for repairing clear defects. However, the deposited film has weak cleaning durability, so it is easily removed by accumulated cleaning process. Although the deposited film is strongly attached on MoSiN(or Qz) film, the adhesive strength between deposited Cr film and MoSiN(or Qz) film becomes weaker and weaker by the accumulated energy when masks are exposed in a scanner tool due to the different coefficient of thermal expansion of each materials. Therefore, whenever a re-pellicle process is needed to a mask, all deposited repair points have to be confirmed whether those deposition film are damaged or not. And if a deposition point is damaged, repair process is needed again. This process causes longer and more complex process. In this paper, the basic theory and the principle are introduced to recover clear defects by using nanomachining tool, and the evaluated results are reviewed at dense line (L/S) patterns and contact hole (C/H) patterns. Also, the results using a nanomachining were compared with those using an e-beam repair tool, including the cleaning durability evaluated by the accumulated cleaning process. Besides, we discuss the phase shift issue and the solution about the image placement error caused by phase error.

  13. Experimental transapical endoscopic ventricular visualization and mitral repair.

    Science.gov (United States)

    Ruttkay, Tamas; Czesla, Markus; Nagy, Henrietta; Götte, Julia; Baksa, Gabor; Patonay, Lajos; Doll, Nicolas; Galajda, Zoltan

    2015-04-01

    An increasing number of experimental beating heart animal studies describe simple transapical mitral valve repairs based on the direct endoscopic visualization of the left ventricle. The aim of our human cadaveric study was to develop a method for more complex transapical endoscopic procedures by on-pump heart operations. After preparation of 20 human fresh cadavers, a standard left anterolateral minithoracotomy was performed in the fifth intercostal space and the pericardium was entered. A rigid 0 degree endoscope and the instruments were introduced through a silicon apical port. To restore the natural form of the left heart, CO2 was insufflated. To test the mitral valve competence, the left ventricle was pressure-injected with saline after each step. After transecting the chords of the A2 segment of the anterior mitral leaflet before the experimental mitral valve repair, the tendinous chord was replaced using an especially designed clip chord. The second part of the experiment consisted of a segmental excision of the P2 segment of the posterior mitral leaflet followed by a standard valvuloplasty and suture annuloplasty. With the help of the described transapical endoscopic mitral valve repair technique, we gained direct visual information of the coaptation line of the mitral leaflets as well as the anatomy and function of the subvalvular apparatus. Using intracardiac imaging, we could perform successful transapical complex mitral repair in each case. The minimally invasive transapical endoscopic method has the potential to offer advantages for on-pump mitral valve repair procedures even in complex mitral valve repair cases. Georg Thieme Verlag KG Stuttgart · New York.

  14. When is cartilage repair successful?; Wann ist eine Knorpelreparatur erfolgreich

    Energy Technology Data Exchange (ETDEWEB)

    Raudner, M.; Roehrich, S.; Zalaudek, M.; Trattnig, S. [Medizinische Universitaet Wien, Exzellenzzentrum Hochfeld-MR, Universitaetsklinik fuer Radiologie und Nuklearmedizin, Wien (Austria); Schreiner, M.M. [Medizinische Universitaet Wien, Universitaetsklinik fuer Orthopaedie, Wien (Austria)

    2017-11-15

    Focal cartilage lesions are a cause of long-term disability and morbidity. After cartilage repair, it is crucial to evaluate long-term progression or failure in a reproducible, standardized manner. This article provides an overview of the different cartilage repair procedures and important characteristics to look for in cartilage repair imaging. Specifics and pitfalls are pointed out alongside general aspects. After successful cartilage repair, a complete, but not hypertrophic filling of the defect is the primary criterion of treatment success. The repair tissue should also be completely integrated to the surrounding native cartilage. After some months, the transplants signal should be isointense compared to native cartilage. Complications like osteophytes, subchondral defects, cysts, adhesion and chronic bone marrow edema or joint effusion are common and have to be observed via follow-up. Radiological evaluation and interpretation of postoperative changes should always take the repair method into account. (orig.) [German] Die Therapie fokaler Knorpelschaeden ist weiterhin eine klinische Herausforderung. Nach erfolgter Sanierung gilt es daher besonders, Erfolg und Misserfolg zu evaluieren und den Verlauf standardisiert und somit reproduzierbar zu beurteilen. Dieser Artikel bietet einen Ueberblick ueber gaengige Reparaturverfahren und deren Charakteristika in der Magnetresonanztomographie. Nach einer erfolgreichen Knorpelreparatur ist eine vollstaendige, aber nicht hypertrophe Fuellung des Knorpeldefekts das primaere Kriterium. Zum umgebenden Nativknorpel ist ausserdem eine durchgehende Integration des Transplantats vordergruendig. Im weiteren postoperativen Verlauf sollte das Transplantat ausserdem ein im Vergleich zu nativem Knorpel isointenses Signalverhalten zeigen. Haeufig beobachtete Komplikationen sind zentrale Osteophyten, subchondrale Defekte, Zysten, chronifizierte Knochenmarksoedeme, Gelenkserguesse oder Adhaesionen. Die radiologische Beurteilung dieser

  15. Outreach Materials for the Collision Repair Campaign

    Science.gov (United States)

    The Collision Repair Campaign offers outreach materials to help collision repair shops reduce toxic air exposure. Materials include a DVD, poster, training video, and materials in Spanish (materiales del outreach en español).

  16. Intern's Experiences with Episiotomy and its Repair

    African Journals Online (AJOL)

    repair is inadequately done, it may leave the woman suffering from perineal pain and other long term conditions with serious impact on the .... The maternity section had an average of ... with the job of performing episiotomy repair necessitating.

  17. Nucleotide excision repair in the test tube.

    NARCIS (Netherlands)

    N.G.J. Jaspers (Nicolaas); J.H.J. Hoeijmakers (Jan)

    1995-01-01

    textabstractThe eukaryotic nucleotide excision-repair pathway has been reconstituted in vitro, an achievement that should hasten the full enzymological characterization of this highly complex DNA-repair pathway.

  18. The Role of Transesophageal Echocardiography in Endovascular Repair of Traumatic Aortic Transection

    Directory of Open Access Journals (Sweden)

    Swathy B

    2014-09-01

    Full Text Available Traumatic rupture of the thoracic aorta is a leading cause of death, following major blunt trauma, and endovascular repair has evolved as a viable alternative to open repair. This report highlights the role of transesophageal echocardiography as a valuable imaging tool for locating the exact position of the lesion, guiding placement of the endograft, detecting leaks around it and supplementing information derived from angiography during endograft deployment.

  19. Regression Models for Repairable Systems

    Czech Academy of Sciences Publication Activity Database

    Novák, Petr

    2015-01-01

    Roč. 17, č. 4 (2015), s. 963-972 ISSN 1387-5841 Institutional support: RVO:67985556 Keywords : Reliability analysis * Repair models * Regression Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 0.782, year: 2015 http://library.utia.cas.cz/separaty/2015/SI/novak-0450902.pdf

  20. Microwave Oven Repair. Teacher Edition.

    Science.gov (United States)

    Smreker, Eugene

    This competency-based curriculum guide for teachers addresses the skills a technician will need to service microwave ovens and to provide customer relations to help retain the customer's confidence in the product and trust in the service company that performs the repair. The guide begins with a task analysis, listing 20 cognitive tasks and 5…

  1. Cloning human DNA repair genes

    International Nuclear Information System (INIS)

    Jeggo, P.A.; Carr, A.M.; Lehmann, A.R.

    1994-01-01

    Many human genes involved in the repair of UV damage have been cloned using different procedures and they have been of great value in assisting the understanding of the mechanism of nucleotide excision-repair. Genes involved in repair of ionizing radiation damage have proved more difficult to isolate. Positional cloning has localized the XRCC5 gene to a small region of chromosome 2q33-35, and a series of yeast artificial chromosomes covering this region have been isolated. Very recent work has shown that the XRCC5 gene encodes the 80 kDa subunit of the Ku DNA-binding protein. The Ku80 gene also maps to this region. Studies with fission yeast have shown that radiation sensitivity can result not only from defective DNA repair but also from abnormal cell cycle control following DNA damage. Several genes involved in this 'check-point' control in fission yeast have been isolated and characterized in detail. It is likely that a similar checkpoint control mechanism exists in human cells. (author)

  2. Pure robotic retrocaval ureter repair

    Directory of Open Access Journals (Sweden)

    Ashok k. Hemal

    2008-12-01

    Full Text Available PURPOSE: To demonstrate the feasibility of pure robotic retrocaval ureter repair. MATERIALS AND METHODS: A 33 year old female presented with right loin pain and obstruction on intravenous urography with the classical "fish-hook" appearance. She was counseled on the various methods of repair and elected to have a robot assisted repair. The following steps are performed during a pure robotic retrocaval ureter repair. The patient is placed in a modified flank position, pneumoperitoneum created and ports inserted. The colon is mobilized to expose the retroperitoneal structures: inferior vena cava, right gonadal vein, right ureter, and duodenum. The renal pelvis and ureter are mobilized and the renal pelvis transected. The ureter is transposed anterior to the inferior vena cava and a pyelopyelostomy is performed over a JJ stent. RESULTS: This patient was discharged on postoperative day 3. The catheter and drain tube were removed on day 1. Her JJ stent was removed at 6 weeks postoperatively. The postoperative intravenous urography at 3 months confirmed normal drainage of contrast medium. CONCLUSION: Pure robotic retrocaval ureter is a feasible procedure; however, there does not appear to be any great advantage over pure laparoscopy, apart from the ergonomic ease for the surgeon as well the simpler intracorporeal suturing.

  3. Discrete time analysis of a repairable machine

    OpenAIRE

    Alfa, Attahiru Sule; Castro, I. T.

    2002-01-01

    We consider, in discrete time, a single machine system that operates for a period of time represented by a general distribution. This machine is subject to failures during operations and the occurrence of these failures depends on how many times the machine has previously failed. Some failures are repairable and the repair times may or may not depend on the number of times the machine was previously repaired. Repair times also have a general distribution. The operating times...

  4. Molecular biological mechanisms I. DNA repair

    International Nuclear Information System (INIS)

    Friedl, A.A.

    2000-01-01

    Cells of all living systems possess a variety of mechanisms that allow to repair spontaneous and exogeneously induced DNA damage. DNA repair deficiencies may invoke enhanced sensitivity towards DNA-damaging agents such as ionizing radiation. They may also enhance the risk of cancer development, both spontaneously or after induction. This article reviews several DNA repair mechanisms, especially those dealing with DNA double-strand breaks, and describes hereditary diseases associated with DNA repair defects. (orig.) [de

  5. Repair of steam turbines by welding

    International Nuclear Information System (INIS)

    Bohnstedt, H.J.; Loebert, P.

    1987-01-01

    In some cases, turbine parts can be repaired by welding, even rotating parts such as the shaft or the blades. Practical examples of successful repair work are explained, as for instance: welding of the last web of the turbine wheel of two MD-rotors, repair of erosion damage on turbine blades, of solid-matter erosion on a medium-pressure blading, or welding repair of a high-pressure turbine casing. (DG) [de

  6. Recent advances in DNA repair and recombination.

    Science.gov (United States)

    Iwanejko, L A; Jones, N J

    1998-09-11

    The subjects of the talks at this 1-day DNA Repair Network meeting, held at City University, London on December 15, 1997, encompassed a range of topics and reflected some of the current areas of research in the United Kingdom. Topics included DNA double-strand break repair, V(D)J recombination, DNA ligases, the RecQ family of helicases and Bloom's syndrome, UVB and immunosuppression, the repair of oxidative damage and mismatch repair mechanisms.

  7. Use of Drosophila to study DNA repair

    International Nuclear Information System (INIS)

    Boyd, J.B.; Harris, P.V.; Sakaguchi, K.

    1988-01-01

    This paper discusses Drosophila, the premier metazoan organism for analyzing many fundamental features of eukaryotic gene regulation. The authors present adaptations of several approaches for studying DNA repair to an analysis of repair-defective mutants in Drosophila. A current understanding of Drosophila DNA repair is described

  8. 30 CFR 56.6801 - Vehicle repair.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Vehicle repair. 56.6801 Section 56.6801 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND... Vehicle repair. Vehicles containing explosive material and oxidizers shall not be taken into a repair...

  9. The two faces of plan repair

    NARCIS (Netherlands)

    Van der Krogt, R.P.J.; De Weerdt, M.M.

    2004-01-01

    Plan repair has two faces. Alternately, a plan repair method looks like a planning method, or looks like a method that does exactly the opposite, i.e., removing actions from a plan. We propose a general framework for plan repair that shows the relation between these two alternating steps. Any plan

  10. 30 CFR 57.14104 - Tire repairs.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Tire repairs. 57.14104 Section 57.14104 Mineral... Devices and Maintenance Requirements § 57.14104 Tire repairs. (a) Before a tire is removed from a vehicle for tire repair, the valve core shall be partially removed to allow for gradual deflation and then...

  11. 30 CFR 56.14104 - Tire repairs.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Tire repairs. 56.14104 Section 56.14104 Mineral... Devices and Maintenance Requirements § 56.14104 Tire repairs. (a) Before a tire is removed from a vehicle for tire repair, the valve core shall be partially removed to allow for gradual deflation and then...

  12. Variations in Velopharyngeal Structure in Adults With Repaired Cleft Palate.

    Science.gov (United States)

    Perry, Jamie L; Kotlarek, Katelyn J; Sutton, Bradley P; Kuehn, David P; Jaskolka, Michael S; Fang, Xiangming; Point, Stuart W; Rauccio, Frank

    2018-01-01

    The purpose of this study was to examine differences in velopharyngeal structures between adults with repaired cleft palate and normal resonance and adults without cleft palate. Thirty-six English-speaking adults, including 6 adults (2 males and 4 females) with repaired cleft palate (M = 32.5 years of age, SD = 17.4 years) and 30 adults (15 males and 15 females) without cleft palate (M = 23.3 years of age, SD = 4.1 years), participated in the study. Fourteen velopharyngeal measures were obtained on magnetic resonance images and compared between groups (cleft and noncleft). After adjusting for body size and sex effects, there was a statistically significant difference between groups for 10 out of the 14 velopharyngeal measures. Compared to those without cleft palate, participants with repaired cleft palate had a significantly shorter hard palate height and length, shorter levator muscle length, shorter intravelar segment, more acute levator angles of origin, shorter and thinner velum, and greater pharyngeal depth. Although significant differences were evident in the cleft palate group, individuals displayed normal resonance. These findings suggest that a wide variability in velopharyngeal anatomy can occur in the presence of normal resonance, particularly for those with repaired cleft palate. Future research is needed to understand how anatomic variability impacts function, such as during speech.

  13. High-order noise analysis for low dose iterative image reconstruction methods: ASIR, IRIS, and MBAI

    Science.gov (United States)

    Do, Synho; Singh, Sarabjeet; Kalra, Mannudeep K.; Karl, W. Clem; Brady, Thomas J.; Pien, Homer

    2011-03-01

    Iterative reconstruction techniques (IRTs) has been shown to suppress noise significantly in low dose CT imaging. However, medical doctors hesitate to accept this new technology because visual impression of IRT images are different from full-dose filtered back-projection (FBP) images. Most common noise measurements such as the mean and standard deviation of homogeneous region in the image that do not provide sufficient characterization of noise statistics when probability density function becomes non-Gaussian. In this study, we measure L-moments of intensity values of images acquired at 10% of normal dose and reconstructed by IRT methods of two state-of-art clinical scanners (i.e., GE HDCT and Siemens DSCT flash) by keeping dosage level identical to each other. The high- and low-dose scans (i.e., 10% of high dose) were acquired from each scanner and L-moments of noise patches were calculated for the comparison.

  14. Is laparoscopic inguinal hernia repair more effective than open repair

    International Nuclear Information System (INIS)

    Aly, O.; Green, A.; Joy, M.; Wong, C.H.; Malik, M

    2011-01-01

    To systematically review randomized controlled trials, (RCT) evidence comparing Lichtenstein to total extraperitoneal (TEP) hernia repair in terms of clinical and cost effectiveness. Study Design: Case series. Place and Duration of Study: The study was conducted at University of Abderdeen, U.K. Methodology: A comprehensive online literature search was undertaken using databases such as MEDLINE, PubMed, EMBASE and Springerlink. Studies were then short listed according to the selection criteria (RCT with over 100 subject and English language publications from 1995 onwards) and appraised using the SIGN Methodology Checklist. A meta analysis of the data was also performed using RevMan software. Results: Analysis of reported data shows that TEP has less postoperative pain and return to work than Lichtenstein method. Operation time is shown to be longer in the TEP but this difference is shortened with increasing surgeon experience. The meta-analysis of the data on complications shows that there are no significant differences between the two types of procedures. TEP causes more short-term recurrences which are attributed to the learning curve effect. Long term recurrence rates on the other hand show no significant differences. At present TEP is slightly more expensive than Lichtenstein repair. Conclusion: Both TEP and Lichtenstein repair are clinically effective procedures. The choice between them should be made on a case-by-case basis; which depends on the patient's preference and characteristics such as age, work and health status. (author)

  15. Metabolic modulation of mammalian DNA excision repair

    Energy Technology Data Exchange (ETDEWEB)

    Schrader, T.J.

    1988-01-01

    First, ultraviolet light (UVL)- and dimethylsulfate (DMS)-induced excision repair was examined in quiescent and lectin-stimulated bovine lymphocytes. Upon mitogenic stimulation, UVL-induced repair increased by a factor of 2 to 3, and reached this maximum 2 days before the onset of DNA replication. However, DMS-induced repair increased sevenfold in parallel with DNA replication. Repair patch sizes were smaller for DMS-induced damage reflecting patches of 7 nucleotides in quiescent lymphocytes compared to 20 nucleotides induced by UVL. The patch size increased during lymphocyte stimulation until one day prior to the peak of DNA replication when patch sizes of 45 and 35 nucleotides were produced in response to UVL- and DMS-induced damage, respectively. At the peak of DNA replication, the patch sizes were equal for both damaging agents at 34 nucleotides. In the second study, a small amount of repair replication was observed in undamaged quiescent and concanavalin A-stimulated bovine lymphocytes as well as in human T98G glioblastoma cells. Repair incorporation doubled in the presence of hydroxyurea. Thirdly, the enhanced repair replication induced by the poly (ADP-ribose) polymerase inhibitor, 3-aminobenzamide, (3-AB), could not be correlated either with an increased rate of repair in the presence of 3-AB or with the use of hydroxyurea in the repair protocol. Finally, treatment of unstimulated lymphocytes with hyperthermia was accompanied by decreased repair replication while the repair patches remained constant at 20 nucleotides.

  16. Complex networks under dynamic repair model

    Science.gov (United States)

    Chaoqi, Fu; Ying, Wang; Kun, Zhao; Yangjun, Gao

    2018-01-01

    Invulnerability is not the only factor of importance when considering complex networks' security. It is also critical to have an effective and reasonable repair strategy. Existing research on network repair is confined to the static model. The dynamic model makes better use of the redundant capacity of repaired nodes and repairs the damaged network more efficiently than the static model; however, the dynamic repair model is complex and polytropic. In this paper, we construct a dynamic repair model and systematically describe the energy-transfer relationships between nodes in the repair process of the failure network. Nodes are divided into three types, corresponding to three structures. We find that the strong coupling structure is responsible for secondary failure of the repaired nodes and propose an algorithm that can select the most suitable targets (nodes or links) to repair the failure network with minimal cost. Two types of repair strategies are identified, with different effects under the two energy-transfer rules. The research results enable a more flexible approach to network repair.

  17. Current Biomechanical Concepts for Rotator Cuff Repair

    Science.gov (United States)

    2013-01-01

    For the past few decades, the repair of rotator cuff tears has evolved significantly with advances in arthroscopy techniques, suture anchors and instrumentation. From the biomechanical perspective, the focus in arthroscopic repair has been on increasing fixation strength and restoration of the footprint contact characteristics to provide early rehabilitation and improve healing. To accomplish these objectives, various repair strategies and construct configurations have been developed for rotator cuff repair with the understanding that many factors contribute to the structural integrity of the repaired construct. These include repaired rotator cuff tendon-footprint motion, increased tendon-footprint contact area and pressure, and tissue quality of tendon and bone. In addition, the healing response may be compromised by intrinsic factors such as decreased vascularity, hypoxia, and fibrocartilaginous changes or aforementioned extrinsic compression factors. Furthermore, it is well documented that torn rotator cuff muscles have a tendency to atrophy and become subject to fatty infiltration which may affect the longevity of the repair. Despite all the aforementioned factors, initial fixation strength is an essential consideration in optimizing rotator cuff repair. Therefore, numerous biomechanical studies have focused on elucidating the strongest devices, knots, and repair configurations to improve contact characteristics for rotator cuff repair. In this review, the biomechanical concepts behind current rotator cuff repair techniques will be reviewed and discussed. PMID:23730471

  18. [Constitutional mismatch repair deficiency syndrome].

    Science.gov (United States)

    Jongmans, Marjolijn C; Gidding, Corrie E; Loeffen, Jan; Wesseling, Pieter; Mensenkamp, Arjen; Hoogerbrugge, Nicoline

    2015-01-01

    Constitutional mismatch repair deficiency (CMMR-D) syndrome is characterised by a significantly increased risk for developing cancer in childhood. It arises when both parents have a mutation in the same mismatch repair gene and pass it on to their child. An 8-year-old girl was diagnosed with CMMR-D syndrome after she developed a brain tumour at the age of 4 and a T-cell non-Hodgkin lymphoma at the age of 6. She had multiple hyperpigmented skin lesions and died of myelodysplastic syndrome at the age of 11. In children with cancer CMMR-D syndrome can be recognized particularly if there are multiple primary malignancies and skin hyperpigmentations and hypopigmentations. The parents of these children are at high risk for colorectal and endometrial cancer (Lynch syndrome), amongst others.

  19. Mitochondrial base excision repair assays

    DEFF Research Database (Denmark)

    Maynard, Scott; de Souza-Pinto, Nadja C; Scheibye-Knudsen, Morten

    2010-01-01

    The main source of mitochondrial DNA (mtDNA) damage is reactive oxygen species (ROS) generated during normal cellular metabolism. The main mtDNA lesions generated by ROS are base modifications, such as the ubiquitous 8-oxoguanine (8-oxoG) lesion; however, base loss and strand breaks may also occur....... Many human diseases are associated with mtDNA mutations and thus maintaining mtDNA integrity is critical. All of these lesions are repaired primarily by the base excision repair (BER) pathway. It is now known that mammalian mitochondria have BER, which, similarly to nuclear BER, is catalyzed by DNA...... glycosylases, AP endonuclease, DNA polymerase (POLgamma in mitochondria) and DNA ligase. This article outlines procedures for measuring oxidative damage formation and BER in mitochondria, including isolation of mitochondria from tissues and cells, protocols for measuring BER enzyme activities, gene...

  20. Primary unilateral cleft lip repair.

    Science.gov (United States)

    Adenwalla, H S; Narayanan, P V

    2009-10-01

    The unilateral cleft lip is a complex deformity. Surgical correction has evolved from a straight repair through triangular and quadrilateral repairs to the Rotation Advancement Technique of Millard. The latter is the technique followed at our centre for all unilateral cleft lip patients. We operate on these at five to six months of age, do not use pre-surgical orthodontics, and follow a protocol to produce a notch-free vermillion. This is easy to follow even for trainees. We also perform closed alar dissection and extensive primary septoplasty in all these patients. This has improved the overall result and has no long-term deleterious effect on the growth of the nose or of the maxilla. Other refinements have been used for prevention of a high-riding nostril, and correction of the vestibular web.

  1. Primary unilateral cleft lip repair

    Directory of Open Access Journals (Sweden)

    Adenwalla H

    2009-10-01

    Full Text Available The unilateral cleft lip is a complex deformity. Surgical correction has evolved from a straight repair through triangular and quadrilateral repairs to the Rotation Advancement Technique of Millard. The latter is the technique followed at our centre for all unilateral cleft lip patients. We operate on these at five to six months of age, do not use pre-surgical orthodontics, and follow a protocol to produce a notch-free vermillion. This is easy to follow even for trainees. We also perform closed alar dissection and extensive primary septoplasty in all these patients. This has improved the overall result and has no long-term deleterious effect on the growth of the nose or of the maxilla. Other refinements have been used for prevention of a high-riding nostril, and correction of the vestibular web.

  2. Large Extremity Peripheral Nerve Repair

    Science.gov (United States)

    2016-12-01

    These antimicrobial peptides are implicated in the resistance of epithelial surfaces to microbial colonisation and have been shown to be upregulated...be equivalent to standard autograft repair in rodent models. Outcomes have now been validated in a large animal (swine) model with 5 cm ulnar nerve...Goals of the Project Task 1– Determine mechanical properties, seal strength and resistance to biodegradation of candidate photochemical nerve wrap

  3. Repair of EL4 leaks

    International Nuclear Information System (INIS)

    1985-03-01

    The reactor shutdown was decided on the 15th of November 1984, because the evolution of the carbon dioxide quantity in the helium blanket of the heavy water. Leaks have been localized on three different channels. Repairs have been made in hard conditions taking into account the reactor state (materials strongly irradiated). The restart has been authorized on the 24th of January 1985 [fr

  4. Mutagenic DNA repair in enterobacteria

    International Nuclear Information System (INIS)

    Sedgwick, S.G.; Chao Ho; Woodgate, R.

    1991-01-01

    Sixteen species of enterobacteria have been screened for mutagenic DNA repair activity. In Escherichia coli, mutagenic DNA repair is encoded by the umuDC operon. Synthesis of UmuD and UmuC proteins is induced as part of the SOS response to DNA damage, and after induction, the UmuD protein undergoes an autocatalytic cleavage to produce the carboxy-terminal UmuD' fragment needed for induced mutagenesis. The presence of a similar system in other species was examined by using a combined approach of inducible-mutagenesis assays, cross-reactivity to E. coli UmuD and UmuD' antibodies to test for induction and cleavage of UmuD-like proteins, and hybridization with E. coli and Salmonella typhimurium u mu DNA probes to map umu-like genes. The results indicate a more widespread distribution of mutagenic DNA repair in other species than was previously thought. They also show that umu loci can be more complex in other species than in E. coli. Differences in UV-induced mutability of more than 200-fold were seen between different species of enteric bacteria and even between multiple natural isolates of E. coli, and yet some of the species which display a poorly mutable phenotype still have umu-like genes and proteins. It is suggested that umuDC genes can be curtailed in their mutagenic activities but that they may still participate in some other, unknown process which provides the continued stimulus for their retention

  5. Comparing Biomechanical Properties, Repair Times, and Value of Common Core Flexor Tendon Repairs.

    Science.gov (United States)

    Chauhan, Aakash; Schimoler, Patrick; Miller, Mark C; Kharlamov, Alexander; Merrell, Gregory A; Palmer, Bradley A

    2018-05-01

    The aim of the study was to compare biomechanical strength, repair times, and repair values for zone II core flexor tendon repairs. A total of 75 fresh-frozen human cadaveric flexor tendons were harvested from the index through small finger and randomized into one of 5 repair groups: 4-stranded cross-stitch cruciate (4-0 polyester and 4-0 braided suture), 4-stranded double Pennington (2-0 knotless barbed suture), 4-stranded Pennington (4-0 double-stranded braided suture), and 6-stranded modified Lim-Tsai (4-0 looped braided suture). Repairs were measured in situ and their repair times were measured. Tendons were linearly loaded to failure and multiple biomechanical values were measured. The repair value was calculated based on operating room costs, repair times, and suture costs. Analysis of variance (ANOVA) and Tukey post hoc statistical analysis were used to compare repair data. The braided cruciate was the strongest repair ( P > .05) but the slowest ( P > .05), and the 4-stranded Pennington using double-stranded suture was the fastest ( P > .05) to perform. The total repair value was the highest for braided cruciate ( P > .05) compared with all other repairs. Barbed suture did not outperform any repairs in any categories. The braided cruciate was the strongest of the tested flexor tendon repairs. The 2-mm gapping and maximum load to failure for this repair approached similar historical strength of other 6- and 8-stranded repairs. In this study, suture cost was negligible in the overall repair cost and should be not a determining factor in choosing a repair.

  6. SU-E-I-93: Improved Imaging Quality for Multislice Helical CT Via Sparsity Regularized Iterative Image Reconstruction Method Based On Tensor Framelet

    International Nuclear Information System (INIS)

    Nam, H; Guo, M; Lee, K; Li, R; Xing, L; Gao, H

    2014-01-01

    Purpose: Inspired by compressive sensing, sparsity regularized iterative reconstruction method has been extensively studied. However, its utility pertinent to multislice helical 4D CT for radiotherapy with respect to imaging quality, dose, and time has not been thoroughly addressed. As the beginning of such an investigation, this work carries out the initial comparison of reconstructed imaging quality between sparsity regularized iterative method and analytic method through static phantom studies using a state-of-art 128-channel multi-slice Siemens helical CT scanner. Methods: In our iterative method, tensor framelet (TF) is chosen as the regularization method for its superior performance from total variation regularization in terms of reduced piecewise-constant artifacts and improved imaging quality that has been demonstrated in our prior work. On the other hand, X-ray transforms and its adjoints are computed on-the-fly through GPU implementation using our previous developed fast parallel algorithms with O(1) complexity per computing thread. For comparison, both FDK (approximate analytic method) and Katsevich algorithm (exact analytic method) are used for multislice helical CT image reconstruction. Results: The phantom experimental data with different imaging doses were acquired using a state-of-art 128-channel multi-slice Siemens helical CT scanner. The reconstructed image quality was compared between TF-based iterative method, FDK and Katsevich algorithm with the quantitative analysis for characterizing signal-to-noise ratio, image contrast, and spatial resolution of high-contrast and low-contrast objects. Conclusion: The experimental results suggest that our tensor framelet regularized iterative reconstruction algorithm improves the helical CT imaging quality from FDK and Katsevich algorithm for static experimental phantom studies that have been performed

  7. Hugh Grant's Image Restoration Discourse: An Actor Apologizes.

    Science.gov (United States)

    Benoit, William L.

    1997-01-01

    Examines the strategies used by actor Hugh Grant (in his appearances on talk shows) to help restore his reputation after he was arrested for lewd behavior with a prostitute. Uses this case as a springboard to contrast entertainment image repair with political and corporate image repair, arguing that important situational differences can be…

  8. Repaired supraspinatus tendons in clinically improving patients: Early postoperative findings and interval changes on MRI

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Eun; Park, Ji Seon; Ryu, Kyung Nam; Rhee, Yong Girl [Kyung Hee University Hospital, Seoul (Korea, Republic of); Yoon, So Hee; Park, So Young; Jin Wook [Dept. of Radiology, Kyung Hee University Hospital at Gangdong, Seoul (Korea, Republic of)

    2015-04-15

    To demonstrate and further determine the incidences of repaired supraspinatus tendons on early postoperative magnetic resonance imaging (MRI) findings in clinically improving patients and to evaluate interval changes on follow-up MRIs. Fifty patients, who showed symptomatic and functional improvements after supraspinatus tendon repair surgery and who underwent postoperative MRI twice with a time interval, were included. The first and the second postoperative MRIs were obtained a mean of 4.4 and 11.5 months after surgery, respectively. The signal intensity (SI) patterns of the repaired tendon on T2-weighted images from the first MRI were classified into three types of heterogeneous high SI with fluid-like bright high foci (type I), heterogeneous high SI without fluid-like bright high foci (type II), and heterogeneous or homogeneous low SI (type III). Interval changes in the SI pattern, tendon thickness, and rotator cuff interval thickness between the two postoperative MRIs were evaluated. The SI patterns on the first MRI were type I or II in 45 tendons (90%) and type III in five (10%). SI decreased significantly on the second MRI (p < 0.050). The mean thickness of repaired tendons and rotator cuff intervals also decreased significantly (p < 0.050). Repaired supraspinatus tendons exhibited high SI in 90% of clinically improving patients on MRI performed during the early postsurgical period. The increased SI and thickness of the repaired tendon decreased on the later MRI, suggesting a gradual healing process rather than a retear.

  9. Repaired supraspinatus tendons in clinically improving patients: Early postoperative findings and interval changes on MRI

    International Nuclear Information System (INIS)

    Lee, Jung Eun; Park, Ji Seon; Ryu, Kyung Nam; Rhee, Yong Girl; Yoon, So Hee; Park, So Young; Jin Wook

    2015-01-01

    To demonstrate and further determine the incidences of repaired supraspinatus tendons on early postoperative magnetic resonance imaging (MRI) findings in clinically improving patients and to evaluate interval changes on follow-up MRIs. Fifty patients, who showed symptomatic and functional improvements after supraspinatus tendon repair surgery and who underwent postoperative MRI twice with a time interval, were included. The first and the second postoperative MRIs were obtained a mean of 4.4 and 11.5 months after surgery, respectively. The signal intensity (SI) patterns of the repaired tendon on T2-weighted images from the first MRI were classified into three types of heterogeneous high SI with fluid-like bright high foci (type I), heterogeneous high SI without fluid-like bright high foci (type II), and heterogeneous or homogeneous low SI (type III). Interval changes in the SI pattern, tendon thickness, and rotator cuff interval thickness between the two postoperative MRIs were evaluated. The SI patterns on the first MRI were type I or II in 45 tendons (90%) and type III in five (10%). SI decreased significantly on the second MRI (p < 0.050). The mean thickness of repaired tendons and rotator cuff intervals also decreased significantly (p < 0.050). Repaired supraspinatus tendons exhibited high SI in 90% of clinically improving patients on MRI performed during the early postsurgical period. The increased SI and thickness of the repaired tendon decreased on the later MRI, suggesting a gradual healing process rather than a retear.

  10. DNA repair in Mycobacterium tuberculosis revisited.

    Science.gov (United States)

    Dos Vultos, Tiago; Mestre, Olga; Tonjum, Tone; Gicquel, Brigitte

    2009-05-01

    Our understanding of Mycobacterium tuberculosis DNA repair mechanisms is still poor compared with that of other bacterial organisms. However, the publication of the first complete M. tuberculosis genome sequence 10 years ago boosted the study of DNA repair systems in this organism. A first step in the elucidation of M. tuberculosis DNA repair mechanisms was taken by Mizrahi and Andersen, who identified homologs of genes involved in the reversal or repair of DNA damage in Escherichia coli and related organisms. Genes required for nucleotide excision repair, base excision repair, recombination, and SOS repair and mutagenesis were identified. Notably, no homologs of genes involved in mismatch repair were identified. Novel characteristics of the M. tuberculosis DNA repair machinery have been found over the last decade, such as nonhomologous end joining, the presence of Mpg, ERCC3 and Hlr - proteins previously presumed to be produced exclusively in mammalian cells - and the recently discovered bifunctional dCTP deaminase:dUTPase. The study of these systems is important to develop therapeutic agents that can counteract M. tuberculosis evolutionary changes and to prevent adaptive events resulting in antibiotic resistance. This review summarizes our current understanding of the M. tuberculosis DNA repair system.

  11. Treatment and Controversies in Paraesophageal Hernia Repair

    Directory of Open Access Journals (Sweden)

    P. Marco eFisichella

    2015-04-01

    Full Text Available Background: Historically all paraesophageal hernias were repaired surgically, today intervention is reserved for symptomatic paraesophageal hernias. In this review, we describe the indications for repair and explore the controversies in paraesophageal hernia repair, which include a comparison of open to laparoscopic paraesophageal hernia repair, the necessity of complete sac excision, the routine performance of fundoplication, and the use of mesh for hernia repair.Methods: We searched Pubmed for papers published between 1980 and 2015 using the following keywords: hiatal hernias, paraesophageal hernias, regurgitation, dysphagia, gastroesophageal reflux disease, aspiration, GERD, endoscopy, manometry, pH monitoring, proton pump inhibitors, anemia, iron deficiency anemia, Nissen fundoplication, sac excision, mesh, mesh repair. Results: Indications for paraesophageal hernia repair have changed, and currently symptomatic paraesophageal hernias are recommended for repair. In addition, it is important not to overlook iron-deficiency anemia and pulmonary complaints, which tend to improve with repair. Current practice favors a laparoscopic approach, complete sac excision, primary crural repair with or without use of mesh, and a routine fundoplication.

  12. Ultrasound determination of rotator cuff tear repairability

    Science.gov (United States)

    Tse, Andrew K; Lam, Patrick H; Walton, Judie R; Hackett, Lisa

    2015-01-01

    Background Rotator cuff repair aims to reattach the torn tendon to the greater tuberosity footprint with suture anchors. The present study aimed to assess the diagnostic accuracy of ultrasound in predicting rotator cuff tear repairability and to assess which sonographic and pre-operative features are strongest in predicting repairability. Methods The study was a retrospective analysis of measurements made prospectively in a cohort of 373 patients who had ultrasounds of their shoulder and underwent rotator cuff repair. Measurements of rotator cuff tear size and muscle atrophy were made pre-operatively by ultrasound to enable prediction of rotator cuff repairability. Tears were classified following ultrasound as repairable or irreparable, and were correlated with intra-operative repairability. Results Ultrasound assessment of rotator cuff tear repairability has a sensitivity of 86% (p tear size (p tear size ≥4 cm2 or anteroposterior tear length ≥25 mm indicated an irreparable rotator cuff tear. Conclusions Ultrasound assessment is accurate in predicting rotator cuff tear repairability. Tear size or anteroposterior tear length and age were the best predictors of repairability. PMID:27582996

  13. Video repairing under variable illumination using cyclic motions.

    Science.gov (United States)

    Jia, Jiaya; Tai, Yu-Wing; Wu, Tai-Pang; Tang, Chi-Keung

    2006-05-01

    This paper presents a complete system capable of synthesizing a large number of pixels that are missing due to occlusion or damage in an uncalibrated input video. These missing pixels may correspond to the static background or cyclic motions of the captured scene. Our system employs user-assisted video layer segmentation, while the main processing in video repair is fully automatic. The input video is first decomposed into the color and illumination videos. The necessary temporal consistency is maintained by tensor voting in the spatio-temporal domain. Missing colors and illumination of the background are synthesized by applying image repairing. Finally, the occluded motions are inferred by spatio-temporal alignment of collected samples at multiple scales. We experimented on our system with some difficult examples with variable illumination, where the capturing camera can be stationary or in motion.

  14. Quantitative assessment of optical properties in healthy cartilage and repair tissue by optical coherence tomography and histology (Conference Presentation)

    Science.gov (United States)

    Jansen, Sanne M. A.; Cernohorsky, Paul; de Bruin, Daniel M.; van der Pol, Edwin; Savci-Heijink, Cemile D.; Strackee, Simon D.; Faber, Dirk J.; van Leeuwen, Ton G.

    2016-02-01

    Quantification of the OCT signal is an important step toward clinical implementation of a diagnostic tool in cartilage imaging. Discrimination of structural cartilage differences in patients with osteoarthritis is critical, yet challenging. This study assesses the variation in the optical attenuation coefficient (μOCT) between healthy cartilage, repair tissue, bone and layers within repair tissue in a controlled setting. OCT and histology was used to assess goat talus articular surfaces in which central osteochondral defects were created. Exact matches of OCT and histology were selected for research. μOCT measurements were taken from healthy cartilage, repair tissue and bone. Measured μOCT in healthy cartilage was higher compared to both repair tissue and bone tissue. Two possible mechanisms for the difference in attenuation were investigated. We studied morphological parameters in terms of nucleus count, nucleus size and inter-nucleus distance. Collagen content in healthy cartilage and repair tissue was assessed using polarization microscopy. Quantitative analysis of the nuclei did not demonstrate a difference in nucleus size and count between healthy cartilage and repair tissue. In healthy cartilage, cells were spaced farther apart and had a lower variation in local nuclear density compared to repair tissue. Polarization microscopy suggested higher collagen content in healthy cartilage compared to repair tissue. μOCT measurements can distinguish between healthy cartilage, repair tissue and bone. Results suggest that cartilage OCT attenuation measurements could be of great impact in clinical diagnostics of osteoarthritis.

  15. A study of everyday repair: informing interaction design

    OpenAIRE

    Maestri, Leah Adriana

    2012-01-01

    Repair is typically seen in design as the restoration of broken objects to their original state. Repair by non-experts, or everyday repair, can often lead to novel forms of repair resulting in the creative repurposing of objects that are often unforeseen by designers. Using a grounded theory approach, this study describes key aspects of repair including: the techniques non-experts employ for repairing their objects; the motivations that prompt acts of repair; and the outcomes that result fr...

  16. International Cartilage Repair Society (ICRS) Recommended Guidelines for Histological Endpoints for Cartilage Repair Studies in Animal Models and Clinical Trials

    Science.gov (United States)

    Hoemann, Caroline; Kandel, Rita; Roberts, Sally; Saris, Daniel B.F.; Creemers, Laura; Mainil-Varlet, Pierre; Méthot, Stephane; Hollander, Anthony P.; Buschmann, Michael D.

    2011-01-01

    Cartilage repair strategies aim to resurface a lesion with osteochondral tissue resembling native cartilage, but a variety of repair tissues are usually observed. Histology is an important structural outcome that could serve as an interim measure of efficacy in randomized controlled clinical studies. The purpose of this article is to propose guidelines for standardized histoprocessing and unbiased evaluation of animal tissues and human biopsies. Methods were compiled from a literature review, and illustrative data were added. In animal models, treatments are usually administered to acute defects created in healthy tissues, and the entire joint can be analyzed at multiple postoperative time points. In human clinical therapy, treatments are applied to developed lesions, and biopsies are obtained, usually from a subset of patients, at a specific time point. In striving to standardize evaluation of structural endpoints in cartilage repair studies, 5 variables should be controlled: 1) location of biopsy/sample section, 2) timing of biopsy/sample recovery, 3) histoprocessing, 4) staining, and 5) blinded evaluation with a proper control group. Histological scores, quantitative histomorphometry of repair tissue thickness, percentage of tissue staining for collagens and glycosaminoglycan, polarized light microscopy for collagen fibril organization, and subchondral bone integration/structure are all relevant outcome measures that can be collected and used to assess the efficacy of novel therapeutics. Standardized histology methods could improve statistical analyses, help interpret and validate noninvasive imaging outcomes, and permit cross-comparison between studies. Currently, there are no suitable substitutes for histology in evaluating repair tissue quality and cartilaginous character. PMID:26069577

  17. Combined laparoscopic and open technique for repair of congenital abdominal hernia

    Science.gov (United States)

    Ye, Qinghuang; Chen, Yan; Zhu, Jinhui; Wang, Yuedong

    2017-01-01

    Abstract Background: Prune belly syndrome (PBS) is a rare congenital disorder among adults, and the way for repairing abdominal wall musculature has no unified standard. Materials and methods: We described combining laparoscopic and open technique in an adult male who presented with PBS. Physical examination and radiological imaging verified the case of PBS. The deficiency of abdominal wall musculature was repaired by combining laparoscopic and open technique using a double-deck complex patch. Results: The patient successfully underwent abdominal wall repair by combining laparoscopic and open technique. Postoperative recovery was uneventful, and improvement in symptom was significant in follow-up after 3, 6, 12, and 24 months. Conclusions: Combining laparoscopic and open technique for repair of deficiency of abdominal wall musculature in PBS was an exploratory way to improve life quality. PMID:29049186

  18. Effect of Moisture Exchange on Interface Formation in the Repair System Studied by X-ray Absorption

    Directory of Open Access Journals (Sweden)

    Mladena Lukovic

    2015-12-01

    Full Text Available In concrete repair systems, material properties of the repair material and the interface are greatly influenced by the moisture exchange between the repair material and the substrate. If the substrate is dry, it can absorb water from the repair material and reduce its effective water-to-cement ratio (w/c. This further affects the hydration rate of cement based material. In addition to the change in hydration rate, void content at the interface between the two materials is also affected. In this research, the influence of moisture exchange on the void content in the repair system as a function of initial saturation level of the substrate is investigated. Repair systems with varying level of substrate saturation are made. Moisture exchange in these repair systems as a function of time is monitored by the X-ray absorption technique. After a specified curing age (3 d, the internal microstructure of the repair systems was captured by micro-computed X-ray tomography (CT-scanning. From reconstructed images, different phases in the repair system (repair material, substrate, voids can be distinguished. In order to quantify the void content, voids were thresholded and their percentage was calculated. It was found that significantly more voids form when the substrate is dry prior to application of the repair material. Air, initially filling voids and pores of the dry substrate, is being released due to the moisture exchange. As a result, air voids remain entrapped in the repair material close to the interface. These voids are found to form as a continuation of pre-existing surface voids in the substrate. Knowledge about moisture exchange and its effects provides engineers with the basis for recommendations about substrate preconditioning in practice.

  19. Effect of Moisture Exchange on Interface Formation in the Repair System Studied by X-ray Absorption.

    Science.gov (United States)

    Lukovic, Mladena; Ye, Guang

    2015-12-22

    In concrete repair systems, material properties of the repair material and the interface are greatly influenced by the moisture exchange between the repair material and the substrate. If the substrate is dry, it can absorb water from the repair material and reduce its effective water-to-cement ratio (w/c). This further affects the hydration rate of cement based material. In addition to the change in hydration rate, void content at the interface between the two materials is also affected. In this research, the influence of moisture exchange on the void content in the repair system as a function of initial saturation level of the substrate is investigated. Repair systems with varying level of substrate saturation are made. Moisture exchange in these repair systems as a function of time is monitored by the X-ray absorption technique. After a specified curing age (3 d), the internal microstructure of the repair systems was captured by micro-computed X-ray tomography (CT-scanning). From reconstructed images, different phases in the repair system (repair material, substrate, voids) can be distinguished. In order to quantify the void content, voids were thresholded and their percentage was calculated. It was found that significantly more voids form when the substrate is dry prior to application of the repair material. Air, initially filling voids and pores of the dry substrate, is being released due to the moisture exchange. As a result, air voids remain entrapped in the repair material close to the interface. These voids are found to form as a continuation of pre-existing surface voids in the substrate. Knowledge about moisture exchange and its effects provides engineers with the basis for recommendations about substrate preconditioning in practice.

  20. Influence of repair length on residual stress in the repair weld of a clad plate

    International Nuclear Information System (INIS)

    Jiang Wenchun; Xu, X.P.; Gong, J.M.; Tu, S.T.

    2012-01-01

    Highlights: ► Residual stress in the repair weld of a stainless steel clad plate is investigated. ► The effect of repair length on residual stress has been studied. ► Large tensile residual stress is generated in the repair weld and heat affected zone. ► With the increase of repair length, transverse stress is decreased. ► Repair length has little effect on longitudinal stress. - Abstract: A 3-D sequential coupling finite element simulation is performed to investigate the temperature field and residual stress in the repair weld of a stainless steel clad plate. The effect of repair length on residual stress has been studied, aiming to provide a reference for repairing the cracked clad plate. The results show that large tensile residual stresses are generated in the repair weld and heat affected zone (HAZ), and then decrease gradually away from the weld and HAZ. The residual stresses through thickness in the clad layer are relative uniform, while they are non-uniform in the base metal. A discontinuous stress distribution is generated across the interface between weld metal and base metal. The repair length has a great effect on transverse stress. With the increase of repair length, the transverse stress is decreased. When the repair length is increased to 14 cm, the peak of transverse stress has been decreased below yield strength, and the transverse stress in the weld and HAZ has also been greatly decreased. But the repair length has little effect on longitudinal stress.

  1. Segmentation of Synchrotron Radiation micro-Computed Tomography Images using Energy Minimization via Graph Cuts

    Energy Technology Data Exchange (ETDEWEB)

    Meneses, Anderson A.M. [Federal University of Western Para (Brazil); Physics Institute, Rio de Janeiro State University (Brazil); Giusti, Alessandro [IDSIA (Dalle Molle Institute for Artificial Intelligence), University of Lugano (Switzerland); Almeida, Andre P. de, E-mail: apalmeid@gmail.com [Physics Institute, Rio de Janeiro State University (Brazil); Nuclear Engineering Program, Federal University of Rio de Janeiro (Brazil); Nogueira, Liebert; Braz, Delson [Nuclear Engineering Program, Federal University of Rio de Janeiro (Brazil); Almeida, Carlos E. de [Radiological Sciences Laboratory, Rio de Janeiro State University (Brazil); Barroso, Regina C. [Physics Institute, Rio de Janeiro State University (Brazil)

    2012-07-15

    The research on applications of segmentation algorithms to Synchrotron Radiation X-Ray micro-Computed Tomography (SR-{mu}CT) is an open problem, due to the interesting and well-known characteristics of SR images, such as the phase contrast effect. The Energy Minimization via Graph Cuts (EMvGC) algorithm represents state-of-art segmentation algorithm, presenting an enormous potential of application in SR-{mu}CT imaging. We describe the application of the algorithm EMvGC with swap move for the segmentation of bone images acquired at the ELETTRA Laboratory (Trieste, Italy). - Highlights: Black-Right-Pointing-Pointer Microstructures of Wistar rats' ribs are investigated with Synchrotron Radiation {mu}CT imaging. Black-Right-Pointing-Pointer The present work is part of a research on the effects of radiotherapy on the thoracic region. Black-Right-Pointing-Pointer Application of the Energy Minimization via Graph Cuts algorithm for segmentation is described.

  2. Segmentation of Synchrotron Radiation micro-Computed Tomography Images using Energy Minimization via Graph Cuts

    International Nuclear Information System (INIS)

    Meneses, Anderson A.M.; Giusti, Alessandro; Almeida, André P. de; Nogueira, Liebert; Braz, Delson; Almeida, Carlos E. de; Barroso, Regina C.

    2012-01-01

    The research on applications of segmentation algorithms to Synchrotron Radiation X-Ray micro-Computed Tomography (SR-μCT) is an open problem, due to the interesting and well-known characteristics of SR images, such as the phase contrast effect. The Energy Minimization via Graph Cuts (EMvGC) algorithm represents state-of-art segmentation algorithm, presenting an enormous potential of application in SR-μCT imaging. We describe the application of the algorithm EMvGC with swap move for the segmentation of bone images acquired at the ELETTRA Laboratory (Trieste, Italy). - Highlights: ► Microstructures of Wistar rats' ribs are investigated with Synchrotron Radiation μCT imaging. ► The present work is part of a research on the effects of radiotherapy on the thoracic region. ► Application of the Energy Minimization via Graph Cuts algorithm for segmentation is described.

  3. B-Spline potential function for maximum a-posteriori image reconstruction in fluorescence microscopy

    Directory of Open Access Journals (Sweden)

    Shilpa Dilipkumar

    2015-03-01

    Full Text Available An iterative image reconstruction technique employing B-Spline potential function in a Bayesian framework is proposed for fluorescence microscopy images. B-splines are piecewise polynomials with smooth transition, compact support and are the shortest polynomial splines. Incorporation of the B-spline potential function in the maximum-a-posteriori reconstruction technique resulted in improved contrast, enhanced resolution and substantial background reduction. The proposed technique is validated on simulated data as well as on the images acquired from fluorescence microscopes (widefield, confocal laser scanning fluorescence and super-resolution 4Pi microscopy. A comparative study of the proposed technique with the state-of-art maximum likelihood (ML and maximum-a-posteriori (MAP with quadratic potential function shows its superiority over the others. B-Spline MAP technique can find applications in several imaging modalities of fluorescence microscopy like selective plane illumination microscopy, localization microscopy and STED.

  4. Laparoscopic repair for vesicouterine fistulae

    Directory of Open Access Journals (Sweden)

    Rafael A. Maioli

    2015-10-01

    Full Text Available ABSTRACT Objective: The purpose of this video is to present the laparoscopic repair of a VUF in a 42-year-old woman, with gross hematuria, in the immediate postoperative phase following a cesarean delivery. The obstetric team implemented conservative management, including Foley catheter insertion, for 2 weeks. She subsequently developed intermittent hematuria and cystitis. The urology team was consulted 15 days after cesarean delivery. Cystoscopy indicated an ulcerated lesion in the bladder dome of approximately 1.0cm in size. Hysterosalpingography and a pelvic computed tomography scan indicated a fistula. Materials and Methods: Laparoscopic repair was performed 30 days after the cesarean delivery. The patient was placed in the lithotomy position while also in an extreme Trendelenburg position. Pneumoperitoneum was established using a Veress needle in the midline infra-umbilical region, and a primary 11-mm port was inserted. Another 11-mm port was inserted exactly between the left superior iliac spine and the umbilicus. Two other 5-mm ports were established under laparoscopic guidance in the iliac fossa on both sides. The omental adhesions in the pelvis were carefully released and the peritoneum between the bladder and uterus was incised via cautery. Limited cystotomy was performed, and the specific sites of the fistula and the ureteral meatus were identified; thereafter, the posterior bladder wall was adequately mobilized away from the uterus. The uterine rent was then closed using single 3/0Vicryl sutures and two-layer watertight closure of the urinary bladder was achieved by using 3/0Vicryl sutures. An omental flap was mobilized and inserted between the uterus and the urinary bladder, and was fixed using two 3/0Vicryl sutures, followed by tube drain insertion. Results: The operative time was 140 min, whereas the blood loss was 100ml. The patient was discharged 3 days after surgery, and the catheter was removed 12 days after surgery

  5. Underwater coating repair cuts nuclear maintenance costs

    International Nuclear Information System (INIS)

    Stuart, C.O.

    1993-01-01

    This article discusses the cleaning and recoating/repair of condensate tanks or other vessels in a nuclear power plant. The topics of the article include the safety and regulatory need for this system of repair, a description of the work done on the Brown's Ferry MK-1 suppression chamber, coating failure mechanisms, qualitative inspection, quantitative inspection, quantitative inspection results, spot repairs, and economic considerations

  6. PTMC in post-MV repair status

    Directory of Open Access Journals (Sweden)

    Lachikarathman Devegowda

    2016-09-01

    Full Text Available MV repair in the rheumatic population is feasible with acceptable long-term results.1 Incidence of mitral stenosis (MS following mitral valve (MV repair for severe rheumatic mitral regurgitation (MR and usefulness of percutaneous transluminal mitral valvuloplasty (PTMC in these patients is not described in literature. We report a case of successful PTMC in severe MS following MV repair for severe rheumatic MR.

  7. Early discharge after external anal sphincter repair

    DEFF Research Database (Denmark)

    Rosenberg, J; Kehlet, H

    1999-01-01

    PURPOSE: The aim of this study was to describe an accelerated-stay program for repair of the external anal sphincter. METHODS: Twenty consecutive patients undergoing overlapping repair of the external anal sphincter were included in the study. Effect parameters were length of hospitalization....... CONCLUSION: We have described a safe accelerated-stay program (24 to 48 hours) for overlapping repair of external anal sphincter....

  8. Endogenous DNA Damage and Repair Enzymes

    Directory of Open Access Journals (Sweden)

    Arne Klungland

    2016-06-01

    Full Text Available Tomas Lindahl completed his medical studies at Karolinska Institute in 1970. Yet, his work has always been dedicated to unraveling fundamental mechanisms of DNA decay and DNA repair. His research is characterized with groundbreaking discoveries on the instability of our genome, the identification of novel DNA repair activities, the characterization of DNA repair pathways, and the association to diseases, throughout his 40 years of scientific career.

  9. Hepatopancreaticobiliary Values after Thoracoabdominal Aneurysm Repair

    OpenAIRE

    Wu, Darrell; Coselli, Joseph S.; Johnson, Michael L.; LeMaire, Scott A.

    2014-01-01

    Background: After thoracoabdominal aortic aneurysm (TAAA) repair, blood tests assessing hepatopancreaticobiliary (HPB) organs commonly have abnormal results. The clinical significance of such abnormalities is difficult to determine because the expected postoperative levels have not been characterized. Therefore, we sought to establish expected trends in HPB laboratory values after TAAA repair. Methods: This 5-year study comprised 155 patients undergoing elective Crawford extent II TAAA repair...

  10. Chromatin dynamics during DSB repair

    Czech Academy of Sciences Publication Activity Database

    Falk, Martin; Lukášová, Emilie; Gabrielová, Barbora; Ondřej, Vladan; Kozubek, Stanislav

    2007-01-01

    Roč. 1773, č. 10 (2007), s. 1534-1545 ISSN 0167-4889 R&D Projects: GA ČR(CZ) GP204/06/P349; GA ČR(CZ) 1QS500040508; GA AV ČR(CZ) IAA1065203; GA MŠk(CZ) 1P05OC084 Institutional research plan: CEZ:AV0Z50040507; CEZ:AV0Z50040702 Keywords : chromatin structure * double- strand breaks (DSB) * DNA repair Subject RIV: BO - Biophysics Impact factor: 4.374, year: 2007

  11. Root justifications for ontology repair

    CSIR Research Space (South Africa)

    Moodley, K

    2011-08-01

    Full Text Available stream_source_info Moodley_2011.pdf.txt stream_content_type text/plain stream_size 32328 Content-Encoding ISO-8859-1 stream_name Moodley_2011.pdf.txt Content-Type text/plain; charset=ISO-8859-1 Root Justi cations... the ontology, based on the no- tion of root justi cations [8, 9]. In Section 5, we discuss the implementation of a Prot eg e3 plugin which demonstrates our approach to ontology repair. In this section we also discuss some experimental results comparing...

  12. Concrete structures protection, repair and rehabilitation

    CERN Document Server

    Woodson, R Dodge

    2009-01-01

    The success of a repair or rehabilitation project depends on the specific plans designed for it. Concrete Structures: Protection, Repair and Rehabilitation provides guidance on evaluating the condition of the concrete in a structure, relating the condition of the concrete to the underlying cause or causes of that condition, selecting an appropriate repair material and method for any deficiency found, and using the selected materials and methods to repair or rehabilitate the structure. Guidance is also provided for engineers focused on maintaining concrete and preparing concrete investigation r

  13. Induced repair and mutagenesis in animal cells

    International Nuclear Information System (INIS)

    Takimoto, Koichi

    1981-01-01

    Induced repair and mutagenesis of animal cells against UV were studied in contrast with SOS repair of E. coli primarily by the use of viruses. Since UV-enhanced reactivation is a phenomenon similar to UV-reactivation (mutagenesis) and the presence of lesion bypass synthsis has been suggested, UV-enhanced reactivation has several common aspects with SOS reactivation of E. coli. However, correlation is not necessarily noted between increase in the viral survival rate and mutagenesis, nor do protease blockers exert any effect. Therefore, SOS repair of E. coli may have different mechansms from induced repair and mutagenesis in animal cells. (Ueda, J.)

  14. DNA damage and repair in plants

    International Nuclear Information System (INIS)

    Britt, A.B.

    1996-01-01

    The biological impact of any DNA damaging agent is a combined function of the chemical nature of the induced lesions and the efficiency and accuracy of their repair. Although much has been learned frommicrobes and mammals about both the repair of DNA damage and the biological effects of the persistence of these lesions, much remains to be learned about the mechanism and tissue-specificity of repair in plants. This review focuses on recent work on the induction and repair of DNA damage in higher plants, with special emphasis on UV-induced DNA damage products. (author)

  15. DNA repair in non-mammalian animals

    International Nuclear Information System (INIS)

    Mitani, Hiroshi

    1984-01-01

    Studies on DNA repair have been performed using microorganisms such as Escherichia coli and cultured human and mammalian cells. However, it is well known that cultured organic cells differ from each other in many respects, although DNA repair is an extremely fundamental function of organisms to protect genetic information from environmental mutagens such as radiation and 0 radicals developing in the living body. To answer the question of how DNA repair is different between the animal species, current studies on DNA repair of cultured vertebrate cells using the methods similar to those in mammalian experiments are reviewed. (Namekawa, K.)

  16. X-ray repair cross complementing protein 1 in base excision repair

    DEFF Research Database (Denmark)

    Hanssen-Bauer, Audun; Solvang-Garten, Karin; Akbari, Mansour

    2012-01-01

    X-ray Repair Cross Complementing protein 1 (XRCC1) acts as a scaffolding protein in the converging base excision repair (BER) and single strand break repair (SSBR) pathways. XRCC1 also interacts with itself and rapidly accumulates at sites of DNA damage. XRCC1 can thus mediate the assembly of large...

  17. CrowdAidRepair: A Crowd-Aided Interactive Data Repairing Method

    KAUST Repository

    Zhou, Jian

    2016-03-25

    Data repairing aims at discovering and correcting erroneous data in databases. Traditional methods relying on predefined quality rules to detect the conflict between data may fail to choose the right way to fix the detected conflict. Recent efforts turn to use the power of crowd in data repairing, but the crowd power has its own drawbacks such as high human intervention cost and inevitable low efficiency. In this paper, we propose a crowd-aided interactive data repairing method which takes the advantages of both rule-based method and crowd-based method. Particularly, we investigate the interaction between crowd-based repairing and rule-based repairing, and show that by doing crowd-based repairing to a small portion of values, we can greatly improve the repairing quality of the rule-based repairing method. Although we prove that the optimal interaction scheme using the least number of values for crowd-based repairing to maximize the imputation recall is not feasible to be achieved, still, our proposed solution identifies an efficient scheme through investigating the inconsistencies and the dependencies between values in the repairing process. Our empirical study on three data collections demonstrates the high repairing quality of CrowdAidRepair, as well as the efficiency of the generated interaction scheme over baselines.

  18. DNA damage repair and radiosensitivity

    International Nuclear Information System (INIS)

    Suzuki, Norio

    2003-01-01

    Tailored treatment is not new in radiotherapy; it has been the major subject for the last 20-30 years. Radiation responses and RBE (relative biological effectiveness) depend on assay systems, endpoints, type of tissues and tumors, radiation quality, dose rate, dose fractionation, physiological and environmental factors etc, Latent times to develop damages also differ among tissues and endpoints depending on doses and radiation quality. Recent progress in clarification of radiation induced cell death, especially of apoptotic cell death, is quite important for understanding radiosensitivity of tumor cure process as well as of tumorigenesis. Apoptotic cell death as well as dormant cells had been unaccounted and missed into a part of reproductive cell death. Another area of major progress has been made in clarifying repair mechanisms of radiation damage, i.e., non-homologous end joining (NHEJ) and homologous recombinational repair (HRR). New approaches and developments such as cDNA or protein micro arrays and so called informatics in addition to basic molecular biological analysis are expected to aid identifying molecules and their roles in signal transduction pathways, which are multi-factorial and interactive each other being involved in radiation responses. (authors)

  19. Predictable repair of provisional restorations.

    Science.gov (United States)

    Hammond, Barry D; Cooper, Jeril R; Lazarchik, David A

    2009-01-01

    The importance of provisional restorations is often downplayed, as they are thought of by some as only "temporaries." As a result, a less-than-ideal provisional is sometimes fabricated, in part because of the additional chair time required to make provisional modifications when using traditional techniques. Additionally, in many dental practices, these provisional restorations are often fabricated by auxillary personnel who may not be as well trained in the fabrication process. Because provisionals play an important role in achieving the desired final functional and esthetic result, a high-quality provisional restoration is essential to fabricating a successful definitive restoration. This article describes a method for efficiently and predictably repairing both methacrylate and bis-acryl provisional restorations using flowable composite resin. By use of this relatively simple technique, provisional restorations can now be modified or repaired in a timely and productive manner to yield an exceptional result. Successful execution of esthetic and restorative dentistry requires attention to detail in every aspect of the case. Fabrication of high-quality provisional restorations can, at times, be challenging and time consuming. The techniques for optimizing resin provisional restorations as described in this paper are pragmatic and will enhance the delivery of dental treatment.

  20. Repairing liner of the reactor

    International Nuclear Information System (INIS)

    Aguilar H, F.

    2001-07-01

    Due to the corrosion problems of the aluminum coating of the reactor pool, a periodic inspections program by ultrasound to evaluate the advance grade and the corrosion speed was settled down. This inspections have shown the necessity to repair some areas, in those that the slimming is significant, of not making it can arrive to the water escape of the reactor pool. The objective of the repair is to place patches of plates of 1/4 inch aluminum thickness in the areas of the reactor 'liner', in those that it has been detected by ultrasound a smaller thickness or similar to 3 mm. To carry out this the fuels are move (of the core and those that are decaying) to a temporary storage, the structure of the core is confined in a tank that this placed inside the pool of the reactor, a shield is placed in the thermal column and it is completely extracted the water for to leave uncover the 'liner' of the reactor. (Author)

  1. KNEE PROPRIOCEPTION FOLLOWING MENISCAL REPAIR

    Directory of Open Access Journals (Sweden)

    Brytsko A. A.

    2018-02-01

    Full Text Available Background. It is well known that meniscectomy leads to osteoarthritis of the knee and proprioception impairment. Objective. The aim of this study was to assess retrospectively the joint position sense after meniscal suture and partial medial meniscal resection and to estimate the patients’ satisfaction with knee function. Material and Methods. We evaluated the outcomes of 27 patients after meniscal repair and compared them to those of 24 patients after partial meniscal resection. We estimated the joint position sense at 30°, 45° and 60° of flexion using the Biodex system 4 Pro. All patients were assessed with the IKDC 2000 subjective knee score. Results. A statistically significant worsening in reproducing the injured joint position in comparison to the healthy limb in both groups was observed. These impairments were mostly expressed at 45° and 60° of knee flexion, and were worsening over time in the group of patients who had undergone medial meniscal resection. An average value by the IKDC 2000 scale after 24 months in the meniscorrhaphy group was 76.73 ± 11.17% and 68.93 ± 14.76% after partial medial meniscal resection. Сonclusion. The control over position of the knee is not impaired after meniscal repair. An overall satisfaction with joint function is higher in patients who undergo meniscal suture in comparison to the partial medial meniscal resection group.

  2. Image, Image, Image

    Science.gov (United States)

    Howell, Robert T.

    2004-01-01

    With all the talk today about accountability, budget cuts, and the closing of programs in public education, teachers cannot overlook the importance of image in the field of industrial technology. It is very easy for administrators to cut ITE (industrial technology education) programs to save school money--money they might shift to teaching the…

  3. Robot technology in remote inspection and repair

    International Nuclear Information System (INIS)

    Lowe, D.B.

    1981-01-01

    The development of remotely controlled equipment for use in a hostile (eg radioactive) environment is reviewed. Inspection and repair work in the core vessel of a nuclear reactor is a particular example of the need for robot devices. Devices with the ability to reach out after entering the interior of the reactor and perform specified operations some distance from the entry axis are needed. It is also necessary to design with tool retrieval emergencies in mind. Should an accident or malfunction prevent withdrawal of the equipment by normal means there must be a fail-safe mechanism of collapse and withdrawal. Visual contact with the device, usually by closed circuit TV is also necessary. Recent developments are described. These include stereoscopic imaging, a flexible arm of increased reach, dexterity and strength, and a computerized robotic arm with seven degrees of freedom to be deployed by the flexible arm. Microprocessors are used to analyse information and command functions. A current solution of the need for precise positioning and tracking of a NDT head round a reactor core is illustrated. (U.K.)

  4. A geometric process repair model for a repairable cold standby system with priority in use and repair

    International Nuclear Information System (INIS)

    Zhang Yuanlin; Wang Guanjun

    2009-01-01

    In this paper, a deteriorating cold standby repairable system consisting of two dissimilar components and one repairman is studied. For each component, assume that the successive working times form a decreasing geometric process while the consecutive repair times constitute an increasing geometric process, and component 1 has priority in use and repair. Under these assumptions, we consider a replacement policy N based on the number of repairs of component 1 under which the system is replaced when the number of repairs of component 1 reaches N. Our problem is to determine an optimal policy N* such that the average cost rate (i.e. the long-run average cost per unit time) of the system is minimized. The explicit equation of the average cost rate of the system is derived and the corresponding optimal replacement policy N* can be determined analytically or numerically. Finally, a numerical example with Weibull distribution is given to illustrate some theoretical results in this paper.

  5. Evaluation of the Risk Factors for a Rotator Cuff Retear After Repair Surgery.

    Science.gov (United States)

    Lee, Yeong Seok; Jeong, Jeung Yeol; Park, Chan-Deok; Kang, Seung Gyoon; Yoo, Jae Chul

    2017-07-01

    A retear is a significant clinical problem after rotator cuff repair. However, no study has evaluated the retear rate with regard to the extent of footprint coverage. To evaluate the preoperative and intraoperative factors for a retear after rotator cuff repair, and to confirm the relationship with the extent of footprint coverage. Cohort study; Level of evidence, 3. Data were retrospectively collected from 693 patients who underwent arthroscopic rotator cuff repair between January 2006 and December 2014. All repairs were classified into 4 types of completeness of repair according to the amount of footprint coverage at the end of surgery. All patients underwent magnetic resonance imaging (MRI) after a mean postoperative duration of 5.4 months. Preoperative demographic data, functional scores, range of motion, and global fatty degeneration on preoperative MRI and intraoperative variables including the tear size, completeness of rotator cuff repair, concomitant subscapularis repair, number of suture anchors used, repair technique (single-row or transosseous-equivalent double-row repair), and surgical duration were evaluated. Furthermore, the factors associated with failure using the single-row technique and transosseous-equivalent double-row technique were analyzed separately. The retear rate was 7.22%. Univariate analysis revealed that rotator cuff retears were affected by age; the presence of inflammatory arthritis; the completeness of rotator cuff repair; the initial tear size; the number of suture anchors; mean operative time; functional visual analog scale scores; Simple Shoulder Test findings; American Shoulder and Elbow Surgeons scores; and fatty degeneration of the supraspinatus, infraspinatus, and subscapularis. Multivariate logistic regression analysis revealed patient age, initial tear size, and fatty degeneration of the supraspinatus as independent risk factors for a rotator cuff retear. Multivariate logistic regression analysis of the single-row group

  6. Repair of large abdominal wall defects with expanded polytetrafluoroethylene (PTFE).

    Science.gov (United States)

    Bauer, J J; Salky, B A; Gelernt, I M; Kreel, I

    1987-01-01

    Most abdominal wall incisional hernias can be repaired by primary closure. However, where the defect is large or there is tension on the closure, the use of a prosthetic material is indicated. Expanded polytetrafluoroethylene (PTFE) patches were used to repair incisional hernias in 28 patients between November 1983 and December 1986. Twelve of these patients (43%) had a prior failure of a primary repair. Reherniation occurred in three patients (10.7%). Wound infections developed in two patients (7.1%), both of whom had existing intestinal stomas, one with an intercurrent pelvic abscess. The prosthetic patch was removed in the patient with the abscess, but the infection was resolved in the other without sequelae. Septic complications did not occur after any operations performed in uncontaminated fields. None of the patients exhibited any undue discomfort, wound pain, erythema, or induration. Complications related to adhesions, erosion of the patch material into the viscera, bowel obstruction, or fistula formation did not occur. Based on this clinical experience, the authors believe that the PTFE patch appears to represent an advance in synthetic abdominal wall substitutes. Images Fig. 1. Fig. 2(left)., Fig. 3(right). PMID:3689012

  7. Repairing method and repairing device of incore structure

    International Nuclear Information System (INIS)

    Uraki, Keiichi; Okamura, Hisanobu; Matsumoto, Toshimi

    1998-01-01

    In structures or equipment made of stainless steel, Ni-based alloy or a low alloy steel and undergoing neutron irradiation and causing a crack-like defect in a reactor pressure vessel, a plate is applied to a region where the crack-like detect is caused, and pressure is applied locally to bond the plate by generated resistance. Namely, electric current is supplied to the portion to be bonded while pressurizing to bond it by generated resistance heat. Then the propagation of cracks can be prevented and occurrence of cracks upon repairing can be prevented relative to a structural member undergoing neutron irradiation in the reactor pressure vessel and causing a crack-like defect thereby enabling to provide effects of preventing occurrence of an accident due to stress corrosion cracking of a nuclear power plant and prolonging the integrity of the plant. (N.H.)

  8. Retear rate in the late postoperative period after arthroscopic rotator cuff repair.

    Science.gov (United States)

    Kim, Jae Hwa; Hong, In Tae; Ryu, Keun Jung; Bong, Sun Tae; Lee, Yoon Seok; Kim, Jang Hwan

    2014-11-01

    Few clinical studies have evaluated the integrity of repaired tendons and identified the timing of retears through the use of serial imaging. Retears after arthroscopic rotator cuff repair are uncommon in the late postoperative period (after 3 months). Case series; Level of evidence, 4. Among 221 arthroscopic rotator cuff repairs that were performed at a single hospital between May 2010 and February 2012, 61 were involved in this study. Rotator cuff tears consisted of 12 small, 31 medium, 8 large, and 6 massive rotator cuff tears. Additionally, 4 isolated subscapularis tears were included. For clinical evaluation, all patients were assessed both preoperatively and postoperatively by use of the University of California-Los Angeles Shoulder Rating Scale, absolute and relative Constant scores, and American Shoulder and Elbow Surgeons score; active range of motion was assessed as well. For radiological evaluation, all 61 patients had a magnetic resonance imaging (MRI) evaluation at 3 months postoperatively. Among them, 23 patients were evaluated for repaired tendon integrity on postoperative MRI at a minimum of 1 year after surgery (mean, 14.1 months; range, 12-19 months), and results were classified according to the Sugaya classification: type I, sufficient thickness with homogeneously low intensity on each image; type II, sufficient thickness, partial high-intensity area; type III, less than half the thickness without discontinuity; type IV, minor discontinuity; and type V, major discontinuity. The remaining 38 patients, who refused to undergo MRI again for financial reasons, were evaluated through ultrasound. Statistically significant clinical improvements were observed after surgery. The MRI conducted at 3 months postoperatively identified 9 patients with Sugaya type I, 28 patients with type II, and 24 patients with type III repairs. No patients showed Sugaya type IV or V repairs at postoperative 3 months. Thirty-seven patients who had shown Sugaya type I or II

  9. Improvement of adhesion performance of mortar-repair interface with inducing crack path into repair

    Directory of Open Access Journals (Sweden)

    A. Satoh

    2015-10-01

    Full Text Available The most important performance for repair materials is adhesion to the substrate. The authors experimentally find out that high modulus fine aggregates in repair material enhance strength of it as well as the strength of the interface repaired with it, compared to the ordinary repair without fine aggregates. This paper elaborates the mechanisms for that with fractographic observation and FEM analysis based on the results of experiment. Also the authors discuss the ways for enhancing the strength and ductility of the repaired mortar

  10. A review of the use of cardiac computed tomography for evaluating the mitral valve before and after mitral valve repair

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Hun; Choi, Jong Bum [Dept. of Thoracic and Cardiovascular Surgery, Chonbuk National University Medical School, Research Institute of Clinical Medicine of Chonbuk National University, Biomedical Research Institute of Chonbuk National University Hospital, Jeonju (Korea, Republic of); Kim, Eun Young; Jin, Gong Yong [Dept. of Radiology, Radiology, Research Institute of Clinical Medicine of Chonbuk National University, Biomedical Research Institute of Chonbuk National University Hospital, Institute for Medical Sciences of Chonbuk National University Medical School, Jeonju (Korea, Republic of)

    2017-09-15

    The role of cardiac computed tomography (CT) for evaluating the mitral valve (MV) has been limited since echocardiography is the main method of evaluation. However, recent advances in cardiac CT have enable detailed evaluation of the anatomy and geometry of the MV. We describe assessments of the anatomy and coaptation geometric parameters of normal MVs, and also review repair of diseased/damaged MV. We also discuss pre- and post-surgical imaging of MV pathology using cardiac CT and various CT images. We found that cardiac CT could be used as an alternative imaging modality to echocardiography for pre-operative MV evaluation and to predict clinical outcomes following repair.

  11. A review of the use of cardiac computed tomography for evaluating the mitral valve before and after mitral valve repair

    International Nuclear Information System (INIS)

    Kim, Jong Hun; Choi, Jong Bum; Kim, Eun Young; Jin, Gong Yong

    2017-01-01

    The role of cardiac computed tomography (CT) for evaluating the mitral valve (MV) has been limited since echocardiography is the main method of evaluation. However, recent advances in cardiac CT have enable detailed evaluation of the anatomy and geometry of the MV. We describe assessments of the anatomy and coaptation geometric parameters of normal MVs, and also review repair of diseased/damaged MV. We also discuss pre- and post-surgical imaging of MV pathology using cardiac CT and various CT images. We found that cardiac CT could be used as an alternative imaging modality to echocardiography for pre-operative MV evaluation and to predict clinical outcomes following repair

  12. International congress on DNA damage and repair: Book of abstracts

    Energy Technology Data Exchange (ETDEWEB)

    1987-01-01

    This document contains the abstracts of 105 papers presented at the Congress. Topics covered include the Escherichia coli nucleotide excision repair system, DNA repair in malignant transformations, defective DNA repair, and gene regulation. (TEM)

  13. International congress on DNA damage and repair: Book of abstracts

    International Nuclear Information System (INIS)

    1987-01-01

    This document contains the abstracts of 105 papers presented at the Congress. Topics covered include the Escherichia coli nucleotide excision repair system, DNA repair in malignant transformations, defective DNA repair, and gene regulation

  14. Laparoscopic Inguinal Hernia Repair in a Developing Nation: Short ...

    African Journals Online (AJOL)

    bilateral hernias, and recurrent hernias), there are data demonstrating an ... no reports of laparoscopic inguinal hernia repair from the. Anglophone ... MATERIALS AND METHODS .... inguinal hernia repair has advantages over open repair for.

  15. DNA Repair and Ethnic Differences in Prostate Cancer Risk

    National Research Council Canada - National Science Library

    Goldman, Radoslav

    2008-01-01

    .... To evaluate this hypothesis we quantify DNA repair capacity in blood cells using comet assay and evaluate how this repair capacity is related to genetic variants in OGG1 and XRCC1 DNA repair genes...

  16. DNA Repair and Ethnic Differences in Prostate Cancer Risk

    National Research Council Canada - National Science Library

    Goldman, Radoslav

    2007-01-01

    .... To evaluate this hypothesis we quantify DNA repair capacity in blood cells using comet assay and evaluate how this repair capacity is related to genetic variants in OGG1 and XRCC1 DNA repair genes...

  17. DNA Repair and Ethnic Differences in Prostate Cancer Risk

    National Research Council Canada - National Science Library

    Goldman, Radoslav

    2006-01-01

    .... To evaluate this hypothesis, we quantify DNA repair capacity in blood cells using comet assay and evaluate how this repair capacity is related to genetic variants in OGG1 and XRCC1 DNA repair genes...

  18. DNA repair related to radiation therapy

    International Nuclear Information System (INIS)

    Klein, W.

    1979-01-01

    The DNA excision repair capacity of peripheral human lymphocytes after radiation therapy has been analyzed. Different forms of application of the radiation during the therapy have been taken into account. No inhibition of repair was found if cells were allowed a certain amount of accomodation to radiation, either by using lower doses or longer application times. (G.G.)

  19. Maintenance and Repair of Concrete Structures

    NARCIS (Netherlands)

    Bijen, J.M.J.M.

    1989-01-01

    In 1987 and 1988 a series of articles was published in the Dutchjournal "Cement" about maintenance and repair of concrete structures. The series was written to promote the transfer of know-how concerning maintenance and repair of concrete structures. Use has been made of know-how developed in the

  20. VEHICLE REPAIR AND MAINTENANCE COSTS IN NIGERIA ...

    African Journals Online (AJOL)

    A standard model was established for the prediction of repair and maintenance costs of vehicles in a non-profit making government parastatal. The model was derived based on data collected over a ten year period from a non-profit making government parastatal, and it predicts repair and maintenance costs as a linear ...

  1. 30 CFR 57.6801 - Vehicle repair.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Vehicle repair. 57.6801 Section 57.6801 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND... and Underground § 57.6801 Vehicle repair. Vehicles containing explosive material and oxidizers shall...

  2. Dysphagia in children with repaired oesophageal atresia

    NARCIS (Netherlands)

    Coppens, C.H.; Engel-Hoek, L. van den; Scharbatke, H.E.; Groot, S.A. de; Draaisma, J.M.T.

    2016-01-01

    Dysphagia is a common problem in children with repaired oesophageal atresia (OA). Abnormalities in the oropharyngeal and oesophageal phase have hardly been studied. The aims of this study were to assess the prevalence of dysphagia in children with repaired OA and to identify and differentiate oral

  3. Human DNA repair and recombination genes

    International Nuclear Information System (INIS)

    Thompson, L.H.; Weber, C.A.; Jones, N.J.

    1988-09-01

    Several genes involved in mammalian DNA repair pathways were identified by complementation analysis and chromosomal mapping based on hybrid cells. Eight complementation groups of rodent mutants defective in the repair of uv radiation damage are now identified. At least seven of these genes are probably essential for repair and at least six of them control the incision step. The many genes required for repair of DNA cross-linking damage show overlap with those involved in the repair of uv damage, but some of these genes appear to be unique for cross-link repair. Two genes residing on human chromosome 19 were cloned from genomic transformants using a cosmid vector, and near full-length cDNA clones of each gene were isolated and sequenced. Gene ERCC2 efficiently corrects the defect in CHO UV5, a nucleotide excision repair mutant. Gene XRCC1 normalizes repair of strand breaks and the excessive sister chromatid exchange in CHO mutant EM9. ERCC2 shows a remarkable /approximately/52% overall homology at both the amino acid and nucleotide levels with the yeast RAD3 gene. Evidence based on mutation induction frequencies suggests that ERCC2, like RAD3, might also be an essential gene for viability. 100 refs., 4 tabs

  4. Tumor relapse present in oncologic nasal repair

    International Nuclear Information System (INIS)

    Galvez Chavez, Julio Cesar; Sanchez Wals, Lenia; Monzon Fernandez, Abel Nicolas; Morales Tirado, Roxana

    2009-01-01

    Tumor relapse is one of the more fearsome complications of the oncologic course and also to obscure the life prognosis, causing the loss of many reconstructions and of exhausting the repairing surgical possibilities. The aim of this study was to determine the relapse frequency, the repercussion on the repair and the subsequent medical course of patients operated on malign nasal tumors

  5. The Weekend Effect in AAA Repair.

    Science.gov (United States)

    O'Donnell, Thomas F X; Li, Chun; Swerdlow, Nicholas J; Liang, Patric; Pothof, Alexander B; Patel, Virendra I; Giles, Kristina A; Malas, Mahmoud B; Schermerhorn, Marc L

    2018-04-18

    Conflicting reports exist regarding whether patients undergoing surgery on the weekend or later in the week experience worse outcomes. We identified patients undergoing abdominal aortic aneurysm (AAA) repair in the Vascular Quality Initiative between 2009 and 2017 [n = 38,498; 30,537 endovascular aneurysm repair (EVAR) and 7961 open repair]. We utilized mixed effects logistic regression to compare adjusted rates of perioperative mortality based on the day of repair. Tuesday was the most common day for elective repair (22%), Friday for symptomatic repairs (20%), and ruptured aneurysms were evenly distributed. Patients with ruptured aneurysms experienced similar adjusted mortality whether they underwent repair during the week or on weekends. Transfers of ruptured AAA were more common over the weekend. However, patients transferred on the weekend experienced higher adjusted mortality than those transferred during the week (28% vs 21%, P = 0.02), despite the fact that during the week, transferred patients actually experienced lower adjusted mortality than patients treated at the index hospital (21% vs 31%, P AAA repair. However, patients with ruptured AAA transferred on the weekend experienced higher mortality than those transferred during the week, suggesting a need for improvement in weekend transfer processes.

  6. Self repairing composites for drone air vehicles

    Science.gov (United States)

    Dry, Carolyn

    2015-04-01

    The objective of this effort was to demonstrate the feasibility of impact-initiated delivery of repair chemicals through hollow fiber architectures embedded within graphite fiber reinforced polymer matrix composites, representative of advanced drone aircraft component material systems. Self-repairing structures through coupon and elements were demonstrated, and evaluated.

  7. 26 CFR 1.162-4 - Repairs.

    Science.gov (United States)

    2010-04-01

    ... the cost of acquisition or production or the gain or loss basis of the taxpayer's plant, equipment, or other property, as the case may be, is not increased by the amount of such expenditures. Repairs in the... incidental repairs which neither materially add to the value of the property nor appreciably prolong its life...

  8. DNA Damage, Repair, and Cancer Metabolism

    Science.gov (United States)

    Turgeon, Marc-Olivier; Perry, Nicholas J. S.; Poulogiannis, George

    2018-01-01

    Although there has been a renewed interest in the field of cancer metabolism in the last decade, the link between metabolism and DNA damage/DNA repair in cancer has yet to be appreciably explored. In this review, we examine the evidence connecting DNA damage and repair mechanisms with cell metabolism through three principal links. (1) Regulation of methyl- and acetyl-group donors through different metabolic pathways can impact DNA folding and remodeling, an essential part of accurate double strand break repair. (2) Glutamine, aspartate, and other nutrients are essential for de novo nucleotide synthesis, which dictates the availability of the nucleotide pool, and thereby influences DNA repair and replication. (3) Reactive oxygen species, which can increase oxidative DNA damage and hence the load of the DNA-repair machinery, are regulated through different metabolic pathways. Interestingly, while metabolism affects DNA repair, DNA damage can also induce metabolic rewiring. Activation of the DNA damage response (DDR) triggers an increase in nucleotide synthesis and anabolic glucose metabolism, while also reducing glutamine anaplerosis. Furthermore, mutations in genes involved in the DDR and DNA repair also lead to metabolic rewiring. Links between cancer metabolism and DNA damage/DNA repair are increasingly apparent, yielding opportunities to investigate the mechanistic basis behind potential metabolic vulnerabilities of a substantial fraction of tumors. PMID:29459886

  9. FLEXOR TENDON REPAIR IN THE HAND

    African Journals Online (AJOL)

    Method of Repair. Cases. AGE, SEX ... method is at fault and not the dexterity of the operator or his technique. .... Physio- therapy seldom makes stiff fingers work, but it prevents .... or repaired later by direct suture, graft or transplant. No. of.

  10. Plan Repair as an Extension of Planning

    NARCIS (Netherlands)

    Van der Krogt, R.P.J.; De Weerdt, M.M.

    2005-01-01

    In dynamic environments, agents have to deal with changing situations. In these cases, repairing a plan is often more efficient than planning from scratch, but existing planning techniques are more advanced than existing plan repair techniques. Therefore, we propose a straightforward method to

  11. Using repair priorities in systems with redundacies

    NARCIS (Netherlands)

    Sleptchenko, A.V.; Adan, I.J.B.F.; Van Houtum, G.-J.

    2014-01-01

    In this paper, we present and analyze a mathematical model for the computation of the system availability for a system of parallel machines with redundancies and repair priorities. Using the presented models, we show that the repair priorities have a strong effect on the performance of the system.

  12. A first population-based long-term outcome study in adults with repaired tetralogy of Fallot in Malta.

    Science.gov (United States)

    Caruana, Maryanne; Grech, Victor

    2017-05-01

    To determine overall and reintervention-free survival for repaired Maltese tetralogy of Fallot patients and to investigate the potential impact of gender, age at repair, genetic syndromes, previous palliation, and type of repair on these outcomes. All 130 tetralogy of Fallot patients born before the end of 1997 included in the local database were extracted. Surgical repair type, age at repair and operative survival were analyzed among the 103/130 repaired patients. Kaplan-Meier survival analyses were performed on the 75 repair survivors with complete follow-up data (mean follow-up 26.37 ± 9.27 (range 9.95-51.21) years). Patients born after 1985 were operated at a younger age (median 1.28 years) compared with patients born before 1985 (median 9.64 years) (P tetralogy of Fallot repair in contemporary patients is very good, cardiac death can occur at any stage and structural reintervention is common. Regular follow-up with imaging and rhythm monitoring remains of utmost importance in all patients. © 2016 Wiley Periodicals, Inc.

  13. Impact of perioperative transesophageal echocardiography on tetralogy of fallot total repair

    Directory of Open Access Journals (Sweden)

    Yasmin Abdel Razek

    2014-03-01

    Conclusion: TEE imaging is a safe, feasible, and accurate tool for anatomical, hemodynamic, and functional assessment in patients with TOF during surgical repair. TEE offers the advantage of permitting visualization of the operative procedure in real time and provides guidance for the surgeon in making decisions inside the operating room.

  14. Mutagenesis and repair of DNA

    International Nuclear Information System (INIS)

    Janion, C.; Grzesiuk, E.; Fabisiewicz, A.; Tudek, B.; Ciesla, J.; Graziewicz, M.; Wojcik, A.; Speina, E.

    1998-01-01

    Full text. The discovery that the mfd gene codes for a transcription-coupling repair factor (TRCF) prompted us to re-investigate the MFD (mutation frequency decline) phenomenon in E.coli K-12 strain when mutations were induced by ultraviolet light, halogen light or MMS-treatment. These studies revealed that: (i) the process of MFD involves the proofreading activity of DNA pol III and the mismatch repair system, as well as, TRCF and the UvrABC-excinuclease (ii) a semi-rich plate test may be replaced by a rich liquid medium, (iii) the T-T pyrimidine dimers are the lesions excised with the highest activity, and (iv) overproduction of UmuD(D'C) proteins leads to a great increase in mutant frequency in irradiated and MMS-treated cells. The role of mismatch repair (MR) in MMS-induced mutagenesis is obscured by the fact that the spectra of mutational specificity are different in bacteria proficient and deficient in MR. It has been found that transposons Tn10 (and Tn5) when inserted into chromosomal DNA of E. coli influence the phenotype lowering the survival and frequency of mutations induced by UV or halogen light irradiation. This is connected with a deficiency of UmuD(D') and UmuC proteins. Transformation of bacteria with plasmids bearing the umuD(D')C genes, suppresses the effects of the transposon insertion, a phenomenon which has not been described before. Single-stranded DNA of M13mp18 phage was oxidized in vitro by a hydroxyl radical generating system including hypoxanthine/xanthine oxidase/Fe3+/EDTA, and it was found that Fapy-Ade, Fapy-Gua, 8-oxyAde and thymine glycol were the main products formed. Replication of the oxidized template by T7 phage DNA polymerase, Klenow fragment of polymerase I, or polymerase beta from bovine thymus has revealed that oxidized pyrimidines are stronger blockers than oxidized purines for T7 phage and Klenow fragment polymerases and the blocking potency depends on the neighboring bases and on the type of polymerase. Studies of

  15. Saturation of DNA repair in mammalian cells

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, F E; Setlow, R B

    1979-01-01

    Excision repair seems to reach a plateau in normal human cells at a 254 nm dose near 20 J/m/sup 2/. We measured excision repair in normal human fibroblasts up to 80 J/m/sup 2/. The four techniques used (unscheduled DNA synthesis, photolysis of BrdUrd incorporated during repair, loss of sites sensitive to a UV endonuclease from Micrococcus luteus, and loss of pyrimidine dimers from DNA) showed little difference between the two doses. Moreover, the loss of endonuclease sites in 24h following two 20 J/m/sup 2/ doses separated by 24h was similar to the loss observed following one dose. Hence, we concluded that the observed plateau in excision repair is real and does not represent some inhibitory process at high doses but a true saturation of one of the rate limiting steps in repair.

  16. On the optimal degree of imperfect repair

    International Nuclear Information System (INIS)

    Finkelstein, Maxim

    2015-01-01

    A simple cost-wise comparison between the minimal and perfect repair of a system is discussed first using a relevant example. The main focus of this note, however, is on imperfect (general) repair. The best repair for our system in this case is defined as the one that corresponds to the optimal level (extent) of repair actions that minimize the long-run expected cost per unit of time. This complex optimization problem is considered for a specific imperfect repair model (Kijima II), using the developed earlier asymptotic approach to the corresponding virtual age modelling. It is shown that the optimal solution exists when the failure rate of a system tends to infinity as t tends to infinity and the corresponding cost function decreases sufficiently fast. An example illustrating the optimization procedure is considered

  17. Contact Dermatitis In Automobile Repair workers

    Directory of Open Access Journals (Sweden)

    Joshi M P

    1997-01-01

    Full Text Available Automobile repair workers are at risk of developing skin morbidity including occupational dermatoses because of their exposure to mineral oils, petroleum products and its derivatives and lubricating oil. This cross- sectional study was carried out at Maharashtra State Road Transport Corporation workshops in Nagpur city to investigate prevalence of skin morbidity including contact dermatitis in automobile repair workers. The study included 288 (49.9% automobile repair workers 180 (31.3% workshop office staff and 109 (18.8% divisional office employees. Dermatitis was the commonest skin morbidity in all the study subjects and it was significantly more prevalent in automobile repair workers. Folliculitis was detected in 13.2% of auto â€" repair workers and was not seen in the other two groups. Increasing trend of skin morbidity was correlated with the length of service of employees. Proper protective measures along with suitable washing facilities should be provided

  18. Imperfect repair and lifesaving in heterogeneous populations

    Energy Technology Data Exchange (ETDEWEB)

    Finkelstein, Maxim [Department of Mathematical Statistics, University of the Free State, PO Box 339, 9300 Bloemfontein (South Africa) and Max Planck Institute for Demographic Research, Rostock (Germany)]. E-mail: FinkelM.SCl@mail.uovs.ac.za

    2007-12-15

    In this theoretical paper we generalize the notion of minimal repair to the heterogeneous case, when the lifetime distribution function can be modeled by continuous or a discrete mixture of distributions. The statistical (black box) minimal repair and the minimal repair based on information just before the failure of an object are considered. The corresponding failure (intensity) rate processes are defined and analyzed. Demographic lifesaving model is also considered: each life is saved (cured) with some probability (or equivalently a proportion of individuals who would have died are now resuscitated and given another chance). Those who are saved experience the statistical minimal repair. Both of these models are based on the Poisson or non-homogeneous Poisson processes of underlying events, which allow for considering heterogeneity. We also consider the new model of imperfect repair in the homogeneous case and present generalizations to the heterogeneous setting.

  19. Stochastic Modelling Of The Repairable System

    Directory of Open Access Journals (Sweden)

    Andrzejczak Karol

    2015-11-01

    Full Text Available All reliability models consisting of random time factors form stochastic processes. In this paper we recall the definitions of the most common point processes which are used for modelling of repairable systems. Particularly this paper presents stochastic processes as examples of reliability systems for the support of the maintenance related decisions. We consider the simplest one-unit system with a negligible repair or replacement time, i.e., the unit is operating and is repaired or replaced at failure, where the time required for repair and replacement is negligible. When the repair or replacement is completed, the unit becomes as good as new and resumes operation. The stochastic modelling of recoverable systems constitutes an excellent method of supporting maintenance related decision-making processes and enables their more rational use.

  20. Male Fertility After Inguinal Hernia Mesh Repair

    DEFF Research Database (Denmark)

    Kohl, Andreas Pagh; Andresen, Kristoffer; Rosenberg, Jacob

    2017-01-01

    OBJECTIVE:: To determine whether patients who receive an inguinal hernia repair father the same number of children as the background population. BACKGROUND:: Although the effect of inguinal hernia repair on male fertility has previously been investigated through indirect measures, no previous...... studies have evaluated the final measure of male fertility, which is the number of children fathered by patients. METHODS:: Prospectively collected data on 32,621 male patients between the ages of 18 and 55 years who received 1 or more inguinal hernia repairs during the years 1998 to 2012 were found in 5...... hernia repair using Lichtenstein technique or laparoscopic approach did not father fewer children than expected. Thus, inguinal hernia repair using Lichtenstein or laparoscopic approach did not impair male fertility....

  1. Oxidative DNA damage & repair: An introduction.

    Science.gov (United States)

    Cadet, Jean; Davies, Kelvin J A

    2017-06-01

    This introductory article should be viewed as a prologue to the Free Radical Biology & Medicine Special Issue devoted to the important topic of Oxidatively Damaged DNA and its Repair. This special issue is dedicated to Professor Tomas Lindahl, co-winner of the 2015 Nobel Prize in Chemistry for his seminal discoveries in the area repair of oxidatively damaged DNA. In the past several years it has become abundantly clear that DNA oxidation is a major consequence of life in an oxygen-rich environment. Concomitantly, survival in the presence of oxygen, with the constant threat of deleterious DNA mutations and deletions, has largely been made possible through the evolution of a vast array of DNA repair enzymes. The articles in this Oxidatively Damaged DNA & Repair special issue detail the reactions by which intracellular DNA is oxidatively damaged, and the enzymatic reactions and pathways by which living organisms survive such assaults by repair processes. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Repair of DNA in xeroderma pigmentosum conjunctiva

    International Nuclear Information System (INIS)

    Newsome, D.A.; Kraemer, K.H.; Robbins, J.H.

    1975-01-01

    Xeroderma pigmentosum (XP) is an autosomal recessive disease with tumor formation on sun-exposed areas of the skin and eyes. Cells from most XP patients are deficient in repairing DNA damaged by ultraviolet (uv) light as shown by a reduced rate of tritiated thymidine (3HTdR) incorporation during their DNA repair synthesis. We have studied such repair synthesis in conjunctival cells from an XP patient with a conjunctival epithelioma and from normal cadaver conjunctiva. Cultured conjunctival cells were irradiated with uv light and then incubated with 3HTdR. Autoradiograms were prepared and showed that uv radiation induced a considerably slower rate of DNA repair synthesis in the XP cells than in normal cells. Many of the ocular abnormalities of XP, including tumor formation, may be the result of this defective DNA repair process

  3. In service inspection and repair of sodium cooled ASTRID prototype

    Energy Technology Data Exchange (ETDEWEB)

    Baque, F.; Jadot, F. [French Atomic Commission, Cadarache Centre, 13108 Saint Paul lez Durance Cedex, (France); Marlier, R. [AREVA, 10 rue Recamier, 69456 Lyon cedex 06, (France); Saillant, J-F. [AREVA/NDE Solutions, 4 rue Thomas Dumorey, BP 70385, 71109 Chalon sur Saone Cedex, (France); Delalande, V. [EDF R and D, 6, quai Watier, 78400 Chatou, (France)

    2015-07-01

    In the frame of the large R and D work which is performed for the future ASTRID sodium cooled prototype, In Service Inspection and Repair (ISI and R) has been identified as a major issue to be taken into account in order to enlarge the plant safety, to consolidate its availability and to protect the associated investment. After the first part of pre-conceptual design phase (2008-2012), the running second part of pre-conceptual phase (2013-2015) allows to increase the ISI and R tool ability for immersed sodium structures of ASTRID, at about 200 deg. C, on the basis of consolidated specifications and thanks to their qualification through more and more realistic laboratory tests and simulation with CIVA code. ISI and R items are being developed and qualified during a pluri-annual program which mainly deals with the reactor block structures, the primary components and circuit, and the Power Conversion System. It ensures a strong connection between the reactor designers and inspection specialists, as the optimization of inspectability and repairability is looked at: this already induced specific rules for design, in order to shorten and ease the ISI and R operations, which have been merged into RCC-MRx rules. In the frame of increasing technology readiness level with corresponding performance demonstration, this paper presents R and D dealing with the ISI and R items: it highlights the sensor development (both ultrasonic and electromagnetic concepts, compatible with sodium at 200 deg. C), then their applications for ASTRID structure control (under sodium telemetry, imaging and NDE). Activity for repair is also presented (a single laser tool for sodium sweeping, machining and welding), and finally the effort for associated robotic (generic program for ASTRID applications, specific technological tools for sodium medium, tight immersed bell). The main results of testing and simulation are given for telemetry, vision, NDE applications, laser process repair and under sodium

  4. Laparoscopic repair of large suprapubic hernias.

    Science.gov (United States)

    Sikar, Hasan Ediz; Çetin, Kenan; Eyvaz, Kemal; Kaptanoglu, Levent; Küçük, Hasan Fehmi

    2017-09-01

    Suprapubic hernia is the term to describe ventral hernias located less than 4 cm above the pubic arch in the midline. Hernias with an upper margin above the arcuate line encounter technical difficulties, and the differences in repair methods forced us to define them as large suprapubic hernias. To present our experience with laparoscopic repair of large suprapubic hernias that allows adequate mesh overlap. Nineteen patients with suprapubic incisional hernias who underwent laparoscopic repair between May 2013 and January 2015 were included in the study. Patients with laparoscopic extraperitoneal repair who had a suprapubic hernia with an upper margin below the arcuate line were excluded. Two men and 17 women, with a mean age of 58.2, underwent laparoscopic repair. Most of the incisions were midline vertical (13/68.4%). Twelve (63.1%) of the patients had previous incisional hernia repair (PIHR group); the mean number of previous incisional hernia repair was 1.4. Mean defect size of the PIHR group was higher than in patients without previous repair - 107.3 cm 2 vs. 50.9 cm 2 (p < 0.05). Mean operating time of the PIHR group was higher than in patients without repair - 126 min vs. 77.9 min (p < 0.05). Although all complications occurred in the PIHR group, there was no statistically significant difference. Laparoscopic repair of large suprapubic hernias can be considered as the first option in treatment. The low recurrence rates reported in the literature and the lack of recurrence, as observed in our study, support this view.

  5. Systems Maintenance Automated Repair Tasks (SMART)

    Science.gov (United States)

    Schuh, Joseph; Mitchell, Brent; Locklear, Louis; Belson, Martin A.; Al-Shihabi, Mary Jo Y.; King, Nadean; Norena, Elkin; Hardin, Derek

    2010-01-01

    SMART is a uniform automated discrepancy analysis and repair-authoring platform that improves technical accuracy and timely delivery of repair procedures for a given discrepancy (see figure a). SMART will minimize data errors, create uniform repair processes, and enhance the existing knowledge base of engineering repair processes. This innovation is the first tool developed that links the hardware specification requirements with the actual repair methods, sequences, and required equipment. SMART is flexibly designed to be useable by multiple engineering groups requiring decision analysis, and by any work authorization and disposition platform (see figure b). The organizational logic creates the link between specification requirements of the hardware, and specific procedures required to repair discrepancies. The first segment in the SMART process uses a decision analysis tree to define all the permutations between component/ subcomponent/discrepancy/repair on the hardware. The second segment uses a repair matrix to define what the steps and sequences are for any repair defined in the decision tree. This segment also allows for the selection of specific steps from multivariable steps. SMART will also be able to interface with outside databases and to store information from them to be inserted into the repair-procedure document. Some of the steps will be identified as optional, and would only be used based on the location and the current configuration of the hardware. The output from this analysis would be sent to a work authoring system in the form of a predefined sequence of steps containing required actions, tools, parts, materials, certifications, and specific requirements controlling quality, functional requirements, and limitations.

  6. [SOS-repair--60 years].

    Science.gov (United States)

    Zavil'gel'skiĭ, G B

    2013-01-01

    This review integrates 60 years of research on SOS-repair and SOS-mutagenesis in procaryotes and eucaryotes, from Jean Weigle experiment in 1953 year (mutagenesis of lambda bacteriophage in UV-irradiated bacteria) to the latest achievements in studying SOS-mutagenesis on all living organisms--Eukarya, Archaea and Bacteria. A key role in establishing of a biochemical basis for SOS-mutagenesis belonges to the finding in 1998-1999 years that specific error-prone DNA polymerases (PolV and others) catalysed translesion synthesis on damaged DNA. This review focuses on recent studies addressing the new models for SOS-induced mutagenesis in Escherichia coli and Home sapiens cells.

  7. Laparoscopic repair of vesicovaginal fistula

    Directory of Open Access Journals (Sweden)

    Miłosz Wilczyński

    2011-06-01

    Full Text Available A vesicovaginal fistula is one of the complications that a gynaecologist is bound to face after oncological operations, especially in postmenopausal women. Over the years there have been introduced many techniques of surgical treatment of this entity, including transabdominal and transvaginal approaches.We present a case of a 46-year-old patient who suffered from urinary leakage via the vagina due to the presence of a vesicovaginal fistula that developed after radical abdominal hysterectomy and subsequent radiotherapy. The decision was made to repair it laparoscopically due to retracted, fibrous and scarred tissue in the vaginal apex that precluded a transvaginal approach. A small cystotomy followed by an excision of fistula borders was performed. After six-month follow-up no recurrence of the disease has been noted.We conclude that laparoscopy is an interesting alternative to traditional approaches that provides comparable results.

  8. Vibration in car repair work.

    Science.gov (United States)

    Hansson, J E; Eklund, L; Kihlberg, S; Ostergren, C E

    1987-03-01

    The main objective of the study was to find efficient hand tools which caused only minor vibration loading. Vibration measurements were carried out under standardised working conditions. The time during which car body repairers in seven companies were exposed to vibration was determined. Chisel hammers, impact wrenches, sanders and saws were the types of tools which generated the highest vibration accelerations. The average daily exposure at the different garages ranged from 22 to 70 min. The risk of vibration injury is currently rated as high. The difference between the highest and lowest levels of vibration was considerable in most tool categories. Therefore the choice of tool has a major impact on the magnitude of vibration exposure. The importance of choosing the right tools and working methods is discussed and a counselling service on vibration is proposed.

  9. Object recognition in images via a factor graph model

    Science.gov (United States)

    He, Yong; Wang, Long; Wu, Zhaolin; Zhang, Haisu

    2018-04-01

    Object recognition in images suffered from huge search space and uncertain object profile. Recently, the Bag-of- Words methods are utilized to solve these problems, especially the 2-dimension CRF(Conditional Random Field) model. In this paper we suggest the method based on a general and flexible fact graph model, which can catch the long-range correlation in Bag-of-Words by constructing a network learning framework contrasted from lattice in CRF. Furthermore, we explore a parameter learning algorithm based on the gradient descent and Loopy Sum-Product algorithms for the factor graph model. Experimental results on Graz 02 dataset show that, the recognition performance of our method in precision and recall is better than a state-of-art method and the original CRF model, demonstrating the effectiveness of the proposed method.

  10. Rotator cuff repair healing influenced by platelet-rich plasma construct augmentation.

    Science.gov (United States)

    Barber, F Alan; Hrnack, Scott A; Snyder, Stephen J; Hapa, Onur

    2011-08-01

    To assess the effect of platelet-rich plasma fibrin matrix (PRPFM) construct augmentation on postoperative tendon healing as determined by magnetic resonance imaging (MRI) and clinical outcome of arthroscopic rotator cuff repair. A comparative series of patients undergoing arthroscopic rotator cuff repair was studied. Two matched groups of patients (20 each) were included: rotator cuff repairs without PRPFM augmentation (group 1) and rotator cuff repairs augmented with 2 sutured platelet-rich plasma (PRP) constructs (group 2). A single-row cuff repair to the normal footprint without tension or marrow vents was performed by a single surgeon. Postoperative rehabilitation was held constant. Postoperative MRI scans were used to evaluate rotator cuff healing. Outcome measures included American Shoulder and Elbow Surgeons, Rowe, Single Assessment Numeric Evaluation, Simple Shoulder Test, and Constant scores. We followed up 40 patients (2 matched groups with 20 patients each) with a mean age of 57 years (range, 44 to 69 years) for a mean of 31 months (range, 24 to 44 months). Postoperative MRI studies showed persistent full-thickness tendon defects in 60% of controls (12 of 20) and 30% of PRPFM-augmented repairs (6 of 20) (P = .03). Of the control group tears measuring less than 3 cm in anteroposterior length, 50% (7 of 14) healed fully, whereas 86% of the PRPFM group tears measuring less than 3 cm in anteroposterior length (12 of 14) healed fully (P rotator cuff tendon repair resulted in lower retear rates identified on MRI than repairs without the constructs. Other than the Rowe scores, there was no postoperative clinical difference by use of standard outcome measures. Level III, case-control study. Copyright © 2011 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  11. A cost analysis of operative repair of major laparoscopic bile duct injuries.

    Science.gov (United States)

    Hofmeyr, S; Krige, J E J; Bornman, P C; Beningfield, S J

    2015-06-01

    Major bile duct injuries occur infrequently after laparoscopic cholecystectomy, but may result in life-threatening complications. Few data exist on the financial implications of duct repair. This study calculated the costs of operative repair in a cohort of patients who underwent reconstruction of the bile duct after major ductal injury. To calculate the total in-hospital cost of surgical repair of patients referred with major bile duct injuries. A prospective database was reviewed to identify all patients referred to the University of Cape Town Private Academic Hospital, South Africa, between 2002 and 2013 for assessment and repair of major laparoscopic bile duct injuries. The detailed clinical records and billing information were evaluated to determine all costs from admission to discharge. Total costs for each patient were adjusted for inflation between the year of repair and 2013. Results. Forty-four patients (33 women, 11 men; median age 48 years, range 30 - 78) underwent reconstruction of a major bile duct injury. First-time repairs were performed at a median of 24.5 days (range 1 - 3,662) after initial surgery. Median hospital stay was 15 days (range 6 - 86). Mean cost of repair was ZAR215,711 (range ZAR68,764 - 980,830). Major contributors to cost were theatre expenses (22%), admission to intensive care (21%), radiology (17%) and specialist fees (12%). Admission to a general ward (10%), consumables (7%), pharmacy (5%), endoscopy (3%) and laboratory costs (3%) made up the balance. The cost of repair of a major laparoscopic bile duct injury is substantial owing to prolonged hospitalisation, complex surgicalintervention and intensive imaging requirements.

  12. Shuttle Repair Tools Automate Vehicle Maintenance

    Science.gov (United States)

    2013-01-01

    Successfully building, flying, and maintaining the space shuttles was an immensely complex job that required a high level of detailed, precise engineering. After each shuttle landed, it entered a maintenance, repair, and overhaul (MRO) phase. Each system was thoroughly checked and tested, and worn or damaged parts replaced, before the shuttle was rolled out for its next mission. During the MRO period, workers needed to record exactly what needed replacing and why, as well as follow precise guidelines and procedures in making their repairs. That meant traceability, and with it lots of paperwork. In 2007, the number of reports generated during electrical system repairs was getting out of hand-placing among the top three systems in terms of paperwork volume. Repair specialists at Kennedy Space Center were unhappy spending so much time at a desk and so little time actually working on the shuttle. "Engineers weren't spending their time doing technical work," says Joseph Schuh, an electrical engineer at Kennedy. "Instead, they were busy with repetitive, time-consuming processes that, while important in their own right, provided a low return on time invested." The strain of such inefficiency was bad enough that slow electrical repairs jeopardized rollout on several occasions. Knowing there had to be a way to streamline operations, Kennedy asked Martin Belson, a project manager with 30 years experience as an aerospace contractor, to co-lead a team in developing software that would reduce the effort required to document shuttle repairs. The result was System Maintenance Automated Repair Tasks (SMART) software. SMART is a tool for aggregating and applying information on every aspect of repairs, from procedures and instructions to a vehicle s troubleshooting history. Drawing on that data, SMART largely automates the processes of generating repair instructions and post-repair paperwork. In the case of the space shuttle, this meant that SMART had 30 years worth of operations

  13. Analysis for a two-dissimilar-component cold standby repairable system with repair priority

    International Nuclear Information System (INIS)

    Leung, Kit Nam Francis; Zhang Yuanlin; Lai, Kin Keung

    2011-01-01

    In this paper, a cold standby repairable system consisting of two dissimilar components and one repairman is studied. Assume that working time distributions and repair time distributions of the two components are both exponential, and Component 1 has repair priority when both components are broken down. After repair, Component 1 follows a geometric process repair while Component 2 obeys a perfect repair. Under these assumptions, using the perfect repair model, the geometric process repair model and the supplementary variable technique, we not only study some important reliability indices, but also consider a replacement policy T, under which the system is replaced when the working age of Component 1 reaches T. Our problem is to determine an optimal policy T* such that the long-run average loss per unit time (i.e. average loss rate) of the system is minimized. The explicit expression for the average loss rate of the system is derived, and the corresponding optimal replacement policy T* can be found numerically. Finally, a numerical example for replacement policy T is given to illustrate some theoretical results and the model's applicability. - Highlights: → A two-dissimilar-component cold standby system with repair priority is formulated. → The successive up/repair times of Component 1 form a decreasing/increasing geometric process. → Not only some reliability indices but also a replacement policy are studied.

  14. Phenomenology of an inducible mutagenic DNA repair pathway in Escherichia coli: SOS repair hypothesis

    International Nuclear Information System (INIS)

    Radman, M.

    1974-01-01

    A hypothesis is proposed according to which E. coli possesses an inducible DNA repair system. This hypothetical repair, which we call SOS repair, is manifested only following damage to DNA, and requires de novo protein synthesis. SOS repair in E. coli requires some known genetic elements: recA + , lex + and probably zab + . Mutagenesis by ultraviolet light is observed only under conditions of functional SOS repair: we therefore suspect that this is a mutation-prone repair. A number of phenomena and experiments is reviewed which at this point can best be interpreted in terms of an inducible mutagenic DNA repair system. Two recently discovered phenomena support the proposed hypothesis: existence of a mutant (tif) which, after a shift to elevated temperature, mimicks the effect of uv irradiation in regard to repair of phage lambda and uv mutagenesis, apparent activation of SOS repair by introduction into the recipient cell of damaged plasmid or Hfr DNA. Several specific predictions based on SOS repair hypothesis are presented in order to stimulate further experimental tests. (U.S.)

  15. Initial experience of laparoscopic incisional hernia repair.

    Science.gov (United States)

    Razman, J; Shaharin, S; Lukman, M R; Sukumar, N; Jasmi, A Y

    2006-06-01

    Laparoscopic repair of ventral and incisional hernia has become increasingly popular as compared to open repair. The procedure has the advantages of minimal access surgery, reduction of post operative pain and the recurrence rate. A prospective study of laparoscopic incisional hernia repair was performed in our center from August 2002 to April 2004. Eighteen cases (n: 18) were performed during the study period. Fifteen cases (n: 15) had open hernia repair previously. Sixteen patients (n: 16) had successful repair of the hernia with the laparoscopic approach and two cases were converted to open repair. The mean hernia defect size was 156cm2. There was no intraoperative or immediate postoperative complication. The mean operating time was 100 +/- 34 minutes (75 - 180 minutes). The postoperative pain was graded as mild to moderate according to visual analogue score. The mean day of discharge after surgery was two days (1 - 3 days). During follow up, three patients (16.7%) developed seroma at the hernia sac which was resolved with conservative management after three weeks. One (5.6%) patient developed recurrence six months after surgery. In conclusion, laparoscopic repair of incisional hernia particularly recurrent hernia has been shown to be safe and effective in our centre. However, careful patient selection and acquiring the necessary advanced laparoscopic surgical skills coupled with the proper use of equipment are mandatory before embarking on this procedure.

  16. Repair of DNA damage in Deinococcus radiodurans

    International Nuclear Information System (INIS)

    Evans, D.M.

    1984-01-01

    The repair of DNA lesions in Deinococcus radiodurans was examined with particular reference to DNA excision repair of ultraviolet light (UV) induced pyrimidine dimers. The characteristics of excision repair via UV endonucleases α and β in vivo varied with respect to (a) the substrate range of the enzymes, (b) the rate of repair of DNA damage (c) the requirement for a protein synthesised in response to DNA damage to attenuate exonuclease action at repairing regions. UV endonuclease α is postulated to incise DNA in a different manner from UV endonuclease β thus defining the method of subsequent repair. Several DNA damage specific endonuclease activities independent of α and β are described. Mutations of the uvsA, uvsF and uvsG genes resulted in an increase in single-strand breaks in response to DNA damage producing uncontrolled DNA degradation. Evidence is presented that these genes have a role in limiting the access of UV endonuclease β to DNA lesions. uvsF and uvsG are also shown to be linked to the mtoA gene. Mutation of uvsH and reo-1 produces further distinct phenotypes which are discussed. An overall model of excision repair of DNA damage in Deinococcus radiodurans is presented. (author)

  17. High performance repairing of reinforced concrete structures

    International Nuclear Information System (INIS)

    Iskhakov, I.; Ribakov, Y.; Holschemacher, K.; Mueller, T.

    2013-01-01

    Highlights: ► Steel fibered high strength concrete is effective for repairing concrete elements. ► Changing fibers’ content, required ductility of the repaired element is achieved. ► Experiments prove previously developed design concepts for two layer beams. -- Abstract: Steel fibered high strength concrete (SFHSC) is an effective material that can be used for repairing concrete elements. Design of normal strength concrete (NSC) elements that should be repaired using SFHSC can be based on general concepts for design of two-layer beams, consisting of SFHSC in the compressed zone and NSC without fibers in the tensile zone. It was previously reported that such elements are effective when their section carries rather large bending moments. Steel fibers, added to high strength concrete, increase its ultimate deformations due to the additional energy dissipation potential contributed by fibers. When changing the fibers’ content, a required ductility level of the repaired element can be achieved. Providing proper ductility is important for design of structures to dynamic loadings. The current study discusses experimental results that form a basis for finding optimal fiber content, yielding the highest Poisson coefficient and ductility of the repaired elements’ sections. Some technological issues as well as distribution of fibers in the cross section of two-layer bending elements are investigated. The experimental results, obtained in the frame of this study, form a basis for general technological provisions, related to repairing of NSC beams and slabs, using SFHSC.

  18. Hepatopancreaticobiliary Values after Thoracoabdominal Aneurysm Repair

    Science.gov (United States)

    Wu, Darrell; Coselli, Joseph S.; Johnson, Michael L.; LeMaire, Scott A.

    2014-01-01

    Background: After thoracoabdominal aortic aneurysm (TAAA) repair, blood tests assessing hepatopancreaticobiliary (HPB) organs commonly have abnormal results. The clinical significance of such abnormalities is difficult to determine because the expected postoperative levels have not been characterized. Therefore, we sought to establish expected trends in HPB laboratory values after TAAA repair. Methods: This 5-year study comprised 155 patients undergoing elective Crawford extent II TAAA repair. In accordance with a prospective study protocol, all repairs involved left-sided heart bypass, selective visceral perfusion, and cold renal perfusion. Blood levels of aspartate transaminase (AST), alanine transaminase (ALT), γ-glutamyl transpeptidase (GGT), lactate dehydrogenase (LDH), total bilirubin, amylase, and lipase were measured before TAAA repair and for 7 days afterward. Ratios between postoperative and baseline levels were compared for each time point with 95% confidence intervals. Results: Temporal patterns for the laboratory values varied greatly. Amylase, lipase, and AST underwent significant early increases before decreasing to preoperative levels. LDH increased immediately and remained significantly elevated, whereas ALT increased more gradually. GGT remained near baseline through postoperative day 4, and then increased to more than twice baseline. Total bilirubin never differed significantly from baseline. After adjusted analysis, the ischemic time predicted the maximum AST, lipase, GGT, and LDH values. Conclusions: Although most HPB laboratory values increase significantly after elective TAAA repair, the temporal trends for different values vary substantially. The ischemic time predicts the maximum AST, lipase, GGT, and LDH levels. These trends should be considered when laboratory values are assessed after TAAA repair. PMID:26798731

  19. Radiation damage and its repair in non-sporulating bacteria

    International Nuclear Information System (INIS)

    Moseley, B.E.B.

    1984-01-01

    A review is given of radiation damage and its repair in non-sporulating bacteria. The identification and measurement of radiation damage in the DNA of the bacteria after exposure to ultraviolet radiation and ionizing radiation is described. Measuring the extent of DNA repair and ways of isolating repair mutants are also described. The DNA repair mechanisms for UV-induced damage are discussed including photoreactivation repair, excision repair, post-replication recombination repair and induced error-prone repair. The DNA repair mechanisms for ionizing radiation damage are also discussed including the repair of both single and double-strand breaks. Other aspects discussed include the effects of growth, irradiation medium and recovery medium on survival, DNA repair in humans, the commercial use of UV and ionizing radiations and the future of ionizing irradiation as a food treatment process. (U.K.)

  20. Diverless pipeline repair system for deep water

    Energy Technology Data Exchange (ETDEWEB)

    Spinelli, Carlo M. [Eni Gas and Power, Milan (Italy); Fabbri, Sergio; Bachetta, Giuseppe [Saipem/SES, Venice (Italy)

    2009-07-01

    SiRCoS (Sistema Riparazione Condotte Sottomarine) is a diverless pipeline repair system composed of a suite of tools to perform a reliable subsea pipeline repair intervention in deep and ultra deep water which has been on the ground of the long lasting experience of Eni and Saipem in designing, laying and operating deep water pipelines. The key element of SiRCoS is a Connection System comprising two end connectors and a repair spool piece to replace a damaged pipeline section. A Repair Clamp with elastomeric seals is also available for pipe local damages. The Connection System is based on pipe cold forging process, consisting in swaging the pipe inside connectors with suitable profile, by using high pressure seawater. Three swaging operations have to be performed to replace the damaged pipe length. This technology has been developed through extensive theoretical work and laboratory testing, ending in a Type Approval by DNV over pipe sizes ranging from 20 inches to 48 inches OD. A complete SiRCoS system has been realised for the Green Stream pipeline, thoroughly tested in workshop as well as in shallow water and is now ready, in the event of an emergency situation.The key functional requirements for the system are: diverless repair intervention and fully piggability after repair. Eni owns this technology and is now available to other operators under Repair Club arrangement providing stand-by repair services carried out by Saipem Energy Services. The paper gives a description of the main features of the Repair System as well as an insight into the technological developments on pipe cold forging reliability and long term duration evaluation. (author)

  1. Repair-modification of radiodamaged genes

    International Nuclear Information System (INIS)

    Volpe, P.; Institute of Experimental Medicine, Rome; Eremenko, T.

    1995-01-01

    It is proposed that through repair-modification, the modified base 5mC may have facilitated the divergent evolution of coding (hypomethylated exon) and uncoding (hypermethylated promoter and intron) sequences in eukaryotic genes. The radioinduced repair patches appearing in regions lacking 5mC are fully reconstructed by excision-repair, whereas those appearing in regions containing 5mC are incompletely reconstructed by this conventional mechanism. Such a second class of repair patches may, however, become fully reconstructed, in the S phase, by repair-modification. In fact, while DNA polymerase β - which is a key enzyme of excision-repair - is active through the whole interphase. DNA methylase - which is responsible for post-synthetic DNA modification - is essentially active in S. Uncoupling of these two enzyme systems, outside S, might explain why in unsynchronised cells repair patches of non-replicating strands are hypomethylated when compared with specific methylation of replicating strands. In other words, excision-repair would always be able to re-establish the primary ATGC language of both damaged unmethylated and methylated regions, while repair-modification would be able to re-establish the modified ATGC(5mC) language of the damaged methylated regions, only in S, but not in G 1 or G 2 . In these two phases, when DNA methylation is inversely correlated with pre-mRNA transcription (as in the case of many tissue-specific genes), such demethylation might induce a silent transcriptional unit to become active. (Author)

  2. DNA excision repair in permeable human fibroblasts

    International Nuclear Information System (INIS)

    Kaufmann, W.K.; Bodell, W.J.; Cleaver, J.E.

    1983-01-01

    U.v. irradiation of confluent human fibroblasts activated DNA repair, aspects of which were characterized in the cells after they were permeabilized. Incubation of intact cells for 20 min between irradiation and harvesting was necessary to obtain a maximum rate of reparative DNA synthesis. Cells harvested immediately after irradiation before repair was initiated displayed only a small stimulation of DNA synthesis, indicating that permeable cells have a reduced capacity to recognize pyrimidine dimers and activate repair. The distribution of sizes of DNA strands labeled during 10 min of reparative DNA synthesis resembled that of parental DNA. However, during a 60-min incubation of permeable cells at 37 degrees C, parental DNA and DNA labeled by reparative DNA synthesis were both cleaved to smaller sizes. Cleavage also occurred in unirradiated cells, indicating that endogenous nuclease was active during incubation. Repair patches synthesized in permeable cells displayed increased sensitivity to digestion by micrococcal nuclease. However, the change in sensitivity during a chase with unlabeled DNA precursors was small, suggesting that reassembly of nucleosome structure at sites of repair was impaired. To examine whether this deficiency was due to a preponderance of incomplete or unligated repair patches, 3H-labeled (repaired) DNA was purified, then digested with exonuclease III and nuclease S1 to probe for free 3' ends and single-stranded regions. About 85% of the [3H]DNA synthesized during a 10-min pulse resisted digestion, suggesting that a major fraction of the repair patches that were filled were also ligated. U.v. light-activated DNA synthesis in permeable cells, therefore, appears to represent the continuation of reparative gap-filling at sites of excision repair activated within intact cells. Gap-filling and ligation were comparatively efficient processes in permeable cells

  3. [Compressive anterior thoracoplasty (modified Abramson's repair) for pectus carinatum repair].

    Science.gov (United States)

    Álvarez Muñoz, V; Prado Valle, M A; López López, A J; Martínez Suárez, M A; Oviedo Gutiérrez, M; Montalvo Ávalos, C; Fernández García, L

    2014-04-15

    For anterior protruding chest wall deformities treatment, mainly pectus carinatum, pediatric surgeons have been managing either orthotic methods or open surgical repairs. Anterior compressive thoracoplasty (Abramson's technique) has widened the therapeutic options. We describe herein a modification of this technique in the first reported Europen series. From 2010 to 2012, a total of five patients (four male and one female) underwent a modified Abramson's technique to correct pectus carinatum or combined protrusion of the chest at our center. We report the operative technique used for these reconstructions. In all five cases, the operation was completed uneventfully and with excellent results either for the surgical team or the patients. Mean operative time was 190 minutes and hospitalization lasted for three to six days, at the time of analgesic drugs withdrawal. We consider the anterior compresive thorocoplasty (modified Abramson's technique) a safe and feasible method to correct protruding chest deformities, particularly in those patients with stiff chest or lack of compliance, in order to avoid the agressive open procedures.

  4. Equipment for construction and repair of pipework

    International Nuclear Information System (INIS)

    Roehrich, H.

    1987-01-01

    More stringent requirements on the integrity of safety-related components in power plants with a view to ensuring the availability of these installations and to rationalizing in-service inspections and repairs have resulted in rapid enhancement of the inspection and repair methods used. Piping systems are increasingly being visually inspected, tested and possibly subjected to remote-control repair from the interior using remotely controlled inspection vehicles. This calls for machines with high levels of reliability which may be operated by means of remote control. Technical developments make it possible nowadays to perform operations that were largely out of the question a decade ago. (orig.) [de

  5. Weld Repair of Thin Aluminum Sheet

    Science.gov (United States)

    Beuyukian, C. S.; Mitchell, M. J.

    1986-01-01

    Weld repairing of thin aluminum sheets now possible, using niobium shield and copper heat sinks. Refractory niobium shield protects aluminum adjacent to hole, while copper heat sinks help conduct heat away from repair site. Technique limits tungsten/inert-gas (TIG) welding bombardment zone to melt area, leaving surrounding areas around weld unaffected. Used successfully to repair aluminum cold plates on Space Shuttle, Commercial applications, especially in sealing fractures, dents, and holes in thin aluminum face sheets or clad brazing sheet in cold plates, heat exchangers, coolers, and Solar panels. While particularly suited to thin aluminum sheet, this process also used in thicker aluminum material to prevent surface damage near weld area.

  6. Sylvia Plath and the failure of emotional self-repair through poetry.

    Science.gov (United States)

    Silverman, M A; Will, N P

    1986-01-01

    Creativity serves not only an aesthetic function but also psychological self-repair for the creative artist. The authors examine the failure of Sylvia Plath's efforts to control her suicidal violence and to bridge her isolation from others via the shared affective experience of poetry. At first, she used traditional forms and mediated images, but when she abandoned them for a more personal expressive art, she lost the shaping, controlling devices she had been using for self-containment and self-repair. They were no longer available to her when she underwent a sweeping narcissistic regression following some very stressful life events. Her emotional deterioration ultimately cost her her life.

  7. Initial Development of Composite Repair Resins With Low Hazardous Air Pollutant Contents

    National Research Council Canada - National Science Library

    LaScala, John J; Bingham, Scott; Andrews, Kevin S; Sands, James M; Palmese, Guiseppe R

    2008-01-01

    Unsaturated polyester-based repair resins, such a Bondo, are widely used for automotive repair, marine repair, sporting equipment repair, and household repair of metal, composites, plastics, and wood...

  8. Long-term successful arthroscopic repair of large and massive rotator cuff tears with a functional and degradable reinforcement device.

    Science.gov (United States)

    Proctor, Christopher S

    2014-10-01

    Rotator cuff repair is a procedure with varying outcomes, and there has been subsequent interest in devices that reinforce the repair and enhance structural and functional outcomes. The objective of this study was to determine these outcomes for arthroscopic repair of large and massive rotator cuff tears augmented with a synthetic absorbable mesh designed specifically for reinforcement of tendon repair by imaging and clinical assessments. Consecutive arthroscopic repairs were performed on 18 patients with large to massive rotator cuff tears by use of a poly-l-lactic acid synthetic patch as a reinforcement device and fixation with 4 sutures. Patients were assessed preoperatively and at 6 months, 12 months, and a mean of 42 months after surgery by the American Shoulder and Elbow Surgeons (ASES) shoulder score to evaluate clinical performance and at 12 months by ultrasound to assess structural repair. Ultrasound showed that 15 of 18 patients had intact rotator cuff repair at 12 months; at 42 months, an additional patient had a failed repair. Patients showed improvement in the ASES shoulder score from 25 preoperatively to 71 at 12 months and 70 at 42 months after surgery. Patients with intact rotator cuff (n = 14) at 42 months had an ASES shoulder score of 82. The poly-l-lactic acid bioabsorbable patch designed specifically to reinforce the surgical repair of tendons supported successful repair of large to massive rotator cuff tears in 83% of patients at 12 months after surgery and 78% of patients at 42 months after surgery, with substantial functional improvement. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  9. To repair or not to repair: with FAVOR there is no question

    Science.gov (United States)

    Garetto, Anthony; Schulz, Kristian; Tabbone, Gilles; Himmelhaus, Michael; Scheruebl, Thomas

    2016-10-01

    of aerial image analysis to the use of data driven decision making to predict and propose the optimized back end of line process flow, productivity and reliability improvements are targeted by smart automation. Additionally the generation of the ideal aerial image from the design and several repair enhancement features offer additional capabilities to improve the efficiency and yield associated with defect handling.

  10. A history of the DNA repair and mutagenesis field: The discovery of base excision repair.

    Science.gov (United States)

    Friedberg, Errol C

    2016-01-01

    This article reviews the early history of the discovery of an DNA repair pathway designated as base excision repair (BER), since in contrast to the enzyme-catalyzed removal of damaged bases from DNA as nucleotides [called nucleotide excision repair (NER)], BER involves the removal of damaged or inappropriate bases, such as the presence of uracil instead of thymine, from DNA as free bases. Copyright © 2015. Published by Elsevier B.V.

  11. The Repaired Rotator Cuff: MRI and Ultrasound Evaluation.

    Science.gov (United States)

    Lee, Susan C; Williams, Danielle; Endo, Yoshimi

    2018-03-01

    The purposes of this review were to provide an overview of the current practice of evaluating the postoperative rotator cuff on imaging and to review the salient imaging findings of the normal and abnormal postoperative rotator cuff, as well as of postoperative complications. The repaired rotator cuff frequently appears abnormal on magnetic resonance imaging (MRI) and ultrasound (US). Recent studies have shown that while the tendons typically normalize, they can demonstrate clinically insignificant abnormal imaging appearances for longer than 6 months. Features of capsular thickening or subacromial-subdeltoid bursal thickening and fluid distension were found to decrease substantially in the first 6-month postoperative period. MRI and US were found to be highly comparable in the postoperative assessment of the rotator cuff, although they had a lower sensitivity for partial thickness tears. Imaging evaluation of newer techniques such as patch augmentation and superior capsular reconstruction needs to be further investigated. MRI and US are useful in the postoperative assessment of the rotator cuff, not only for evaluation of the integrity of the rotator cuff, but also for detecting hardware complications and other etiologies of shoulder pain.

  12. Pulpal progenitors and dentin repair.

    Science.gov (United States)

    Harichane, Y; Hirata, A; Dimitrova-Nakov, S; Granja, I; Goldberg, A; Kellermann, O; Poliard, A

    2011-07-01

    Mesenchymal stem cells are present in the dental pulp. They have been shown to contribute to dentin-like tissue formation in vitro and to participate in bone repair after a mandibular lesion. However, their capacity to contribute efficiently to reparative dentin formation after pulp lesion has never been explored. After pulp exposure, we have identified proliferative cells within 3 zones. In the crown, zone I is near the cavity, and zone II corresponds to the isthmus between the mesial and central pulp. In the root, zone III, near the apex, at a distance from the inflammatory site, contains mitotic stromal cells which may represent a source of progenitor cells. Stem-cell-based strategies are promising treatments for tissue injury in dentistry. Our experiments focused on (1) location of stem cells induced to leave their quiescent state early after pulp injury and (2) implantation of pulp progenitors, a substitute for classic endodontic treatments, paving the way for pulp stem-cell-based therapies.

  13. Fanconi anemia and DNA repair.

    Science.gov (United States)

    Grompe, M; D'Andrea, A

    2001-10-01

    Fanconi anemia (FA) is an autosomal recessive disorder caused by defects in at least eight distinct genes FANCA, B, C, D1, D2, E, F and G. The clinical phenotype of all FA complementation groups is similar and is characterized by progressive bone marrow failure, cancer proneness and typical birth defects. The principal cellular phenotype is hypersensitivity to DNA damage, particularly interstrand DNA crosslinks. The FA proteins constitute a multiprotein pathway whose precise biochemical function(s) remain unknown. Five of the FA proteins (FANCA, C, E, F and G) interact in a nuclear complex upstream of FANCD2. FANCB and FANCD1 have not yet been cloned, but it is likely that FANCB is part of the nuclear complex and that FANCD1 acts downstream of FANCD2. The FA nuclear complex regulates the mono-ubiquitination of FANCD2 in response to DNA damage, resulting in targeting of this protein into nuclear foci. These foci also contain BRCA1 and other DNA damage response proteins. In male meiosis, FANCD2 also co-localizes with BRCA1 at synaptonemal complexes. Together, these data suggest that the FA pathway functions primarily as a DNA damage response system, although its exact role (direct involvement in DNA repair versus indirect, facilitating role) has not yet been defined.

  14. Method for repairing failed fuel

    International Nuclear Information System (INIS)

    Shakudo, Taketomi.

    1986-01-01

    Purpose: To repair fuel elements that became failed during burnup in a reactor or during handling. Method: After the surface in the vicinity of a failed part of a fuel element is cleaned, a socket made of a shape-memory alloy having a ring form or a horseshoe form made by cutting a part of the ring form is inserted into the failed position according to the position of the failed fuel element. The shape memory alloy socket remembers a slightly larger inside diameter in its original phase (high-temperature side) than the outside diameter of the cladding tube and also a slightly larger inside diameter of the socket in the martensite phase (low-temperature side) than the outside diameter of the cladding tube, such that the socket can easily be inserted into the failed position. The socket, inserted into the failed part of the cladding tube, is heated by a heating jig. The socket recovers the original phase, and the shape also tends to recover a smaller diameter than the outside diameter of the cladding tube that has been remembered, and accordingly the failed part of the cladding tube is fastened with a great force and the failed part is fully closed with the socket, thus keeping radioactive materials from going out. (Horiuchi, T.)

  15. Protection and repair of the ischemic heart

    NARCIS (Netherlands)

    Koudstaal, S.

    2014-01-01

    This thesis aimed to elucidate and advance strategies for cardioprotection and cardiac repair, translate preclinical findings towards future clinical studies and optimize the translational research process for IHD. So far, many cardioprotective strategies against reperfusion injury could not be

  16. Radiation repair models for clinical application.

    Science.gov (United States)

    Dale, Roger G

    2018-02-28

    A number of newly emerging clinical techniques involve non-conventional patterns of radiation delivery which require an appreciation of the role played by radiation repair phenomena. This review outlines the main models of radiation repair, focussing on those which are of greatest clinical usefulness and which may be incorporated into biologically effective dose assessments. The need to account for the apparent "slowing-down" of repair rates observed in some normal tissues is also examined, along with a comparison of the relative merits of the formulations which can be used to account for such phenomena. Jack Fowler brought valuable insight to the understanding of radiation repair processes and this article includes reference to his important contributions in this area.

  17. BIDIRECTIONAL FUNCTION OF SHENGHE POWDER ON REPAIR ...

    African Journals Online (AJOL)

    USER

    Keywords: DNA repair, radiation, glioma, astrocyte, Chinese herbs. Introduction .... Wet transfer was performed for 4 hr at constant voltage (40 V) using polyvinylidene difluoride membrane ..... Mitochondrial survivin inhibits apoptosis and.

  18. Optimal maintenance policies in incomplete repair models

    International Nuclear Information System (INIS)

    Kahle, Waltraud

    2007-01-01

    We consider an incomplete repair model, that is, the impact of repair is not minimal as in the homogeneous Poisson process and not 'as good as new' as in renewal processes but lies between these boundary cases. The repairs are assumed to impact the failure intensity following a virtual age process of the general form proposed by Kijima. In previous works field data from an industrial setting were used to fit several models. In most cases the estimated rate of occurrence of failures was that of an underlying exponential distribution of the time between failures. In this paper, it is shown that there exist maintenance schedules under which the failure behavior of the failure-repair process becomes a homogeneous Poisson process

  19. F-111 Bonded Panel Repair Status

    National Research Council Canada - National Science Library

    Rider, Andrew

    1999-01-01

    A visit was made to Amberley Airbase between the 6th and 9th of September to consult with RAAF staff on current procedures and problems involved in the maintenance and repair of F-lll honeycomb panels...

  20. Feedwater connection repair and modification at GKN

    Energy Technology Data Exchange (ETDEWEB)

    Witteman, C; Klees, J E

    1985-03-01

    From January to March 1983 the feedwater connection of GKN was repaired using a boring lathe, spark machining and semi-automatic welding. Nondestructive examination was performed by ultrasonic and eddy-current testing.

  1. Resterilized Polypropylene Mesh for Inguinal Hernia Repair

    African Journals Online (AJOL)

    2018-04-19

    Apr 19, 2018 ... Conclusion: The use of sterilized polypropylene mesh for the repair of inguinal ... and nonabsorbable materials to reduce the tissue–mesh. INTRODUCTION ... which we have been practicing in our center since we introduced ...

  2. DNA repair phenotype and dietary antioxidant supplementation

    DEFF Research Database (Denmark)

    Guarnieri, Serena; Loft, Steffen; Riso, Patrizia

    2008-01-01

    Phytochemicals may protect cellular DNA by direct antioxidant effect or modulation of the DNA repair activity. We investigated the repair activity towards oxidised DNA in human mononuclear blood cells (MNBC) in two placebo-controlled antioxidant intervention studies as follows: (1) well-nourished......Phytochemicals may protect cellular DNA by direct antioxidant effect or modulation of the DNA repair activity. We investigated the repair activity towards oxidised DNA in human mononuclear blood cells (MNBC) in two placebo-controlled antioxidant intervention studies as follows: (1) well......-nourished subjects who ingested 600 g fruits and vegetables, or tablets containing the equivalent amount of vitamins and minerals, for 24 d; (2) poorly nourished male smokers who ingested 500 mg vitamin C/d as slow- or plain-release formulations together with 182 mg vitamin E/d for 4 weeks. The mean baseline levels...

  3. Chemical repair of trypsin-histidinyl radical

    International Nuclear Information System (INIS)

    Jovanovic, S.V.; Ruvarac, I.; Jankovic, I.; Josimovic, L.

    1991-01-01

    Oxyl radicals, such as hydroxyl, alkoxyl and peroxyl, react with biomolecules to produce bioradicals. Unless chemically repaired by suitable antioxidants, these bioradicals form stable products. This leads to loss of biological function of parent biomolecules with deleterious biological results, such as mutagenesis and cancer. Consequently, the understanding of the mechanisms of oxyl radical damage to biomolecules and chemical repair of such damage is crucial for the development of strategies for anticarcinogenesis and radioprotection. In this study the chemical repair of the histidinyl radical generated upon the trichloromethylperoxyl radical reaction with trypsin vas investigated by gamma radiolysis. The trypsin histidinyl radical is a resonance-stabilized heterocyclic free radical which was found to be unreactive with oxygen. The efficacy of the chemical repair of the trypsin-histidinyl radical by endogenous antioxidants which are electron donors (e.g. 5-hydroxytryptophan, uric acid) is compared to that of antioxidants which are H-atom donors (e. g. glutathione). 9 refs., 2 figs., 1 tab

  4. Feedwater connection repair and modification at GKN

    International Nuclear Information System (INIS)

    Witteman, C.; Klees, J.E.

    1985-01-01

    From Jan. to March 1983 the feedwater connection of GKN was repaired using a boring lathe, spark machining and semi-automatic welding. Nondestructive examination was performed by ultrasonic and eddy-current testing

  5. DNA replication and repair in Tilapia cells

    International Nuclear Information System (INIS)

    Yew, F.H.; Chang, L.M.

    1984-01-01

    The effect of ultraviolet radiation on a cell line established from the warm water fish Tilapia has been assessed by measuring the rate of DNA synthesis, excision repair, post-replication repair and cell survival. The cells tolerate ultraviolet radiation better than mammalian cells with respect to DNA synthesis, post-replication repair and cell survival. They are also efficient in excision repair, which in other fish cell lines has been found to be at a low level or absent. Their response to the inhibitors hydroxyurea and 1-β-D-arabinofuranosylcytosine is less sensitive than that of other cell lines, yet the cells seem to have very small pools of DNA precursor. (author)

  6. Funding of Facility Repairs and Renovation.

    Science.gov (United States)

    Kaiser, Harvey H.

    1984-01-01

    Compares the life cycle approach for campus building repair and renovation to the University of California's comprehensive building maintenance formula and advises that formulas be used cautiously as a method of determining appropriate budget levels. (MLF)

  7. 49 CFR 192.719 - Transmission lines: Testing of repairs.

    Science.gov (United States)

    2010-10-01

    ... pipe before it is installed. (b) Testing of repairs made by welding. Each repair made by welding in... 49 Transportation 3 2010-10-01 2010-10-01 false Transmission lines: Testing of repairs. 192.719... Transmission lines: Testing of repairs. (a) Testing of replacement pipe. If a segment of transmission line is...

  8. Arthroscopic Hip Labral Repair: The Iberian Suture Technique

    OpenAIRE

    Stubbs, Allston J.; Andersen, Jason S.; Mannava, Sandeep; Wooster, Benjamin M.; Howse, Elizabeth A.; Winter, S. Bradley

    2014-01-01

    Arthroscopic hip labral repair has beneficial short-term outcomes; however, debate exists regarding ideal surgical labral repair technique. This technical note presents an arthroscopic repair technique that uses intrasubstance labral suture passage to restore the chondrolabral interface. This “Iberian suture technique” allows for an anatomic repair while posing minimal risk of damage to the labral and chondral tissues.

  9. A Minimum Cost Flow model for Level of Repair Analysis

    NARCIS (Netherlands)

    Basten, Robertus Johannes Ida; Schutten, Johannes M.J.; van der Heijden, Matthijs C.

    2008-01-01

    Given a product design and a repair network for capital goods, a level of repair analysis determines for each component in the product (1) whether it should be discarded or repaired upon failure and (2) at which location in the repair network to do this. In this paper, we show how the problem can be

  10. A minimum cost flow model for level of repair analysis

    NARCIS (Netherlands)

    Basten, Robertus Johannes Ida; van der Heijden, Matthijs C.; Schutten, Johannes M.J.

    2011-01-01

    Given a product design and a repair network for capital goods, a level of repair analysis determines for each component in the product (1) whether it should be discarded or repaired upon failure and (2) at which location in the repair network to do this. In this paper, we show how the problem can be

  11. Autologous chondrocyte implantation: superior biologic properties of hyaline cartilage repairs.

    Science.gov (United States)

    Henderson, Ian; Lavigne, Patrick; Valenzuela, Herminio; Oakes, Barry

    2007-02-01

    Information regarding the quality of autologous chondrocyte implantation repair is needed to determine whether the current autologous chondrocyte implantation surgical technology and the subsequent biologic repair processes are capable of reliably forming durable hyaline or hyaline-like cartilage in vivo. We report and analyze the properties and qualities of autologous chondrocyte implantation repairs. We evaluated 66 autologous chondrocyte implantation repairs in 57 patients, 55 of whom had histology, indentometry, and International Cartilage Repair Society repair scoring at reoperation for mechanical symptoms or pain. International Knee Documentation Committee scores were used to address clinical outcome. Maximum stiffness, normalized stiffness, and International Cartilage Repair Society repair scoring were higher for hyaline articular cartilage repairs compared with fibrocartilage, with no difference in clinical outcome. Reoperations revealed 32 macroscopically abnormal repairs (Group B) and 23 knees with normal-looking repairs in which symptoms leading to arthroscopy were accounted for by other joint disorders (Group A). In Group A, 65% of repairs were either hyaline or hyaline-like cartilage compared with 28% in Group B. Autologous chondrocyte repairs composed of fibrocartilage showed more morphologic abnormalities and became symptomatic earlier than hyaline or hyaline-like cartilage repairs. The hyaline articular cartilage repairs had biomechanical properties comparable to surrounding cartilage and superior to those associated with fibrocartilage repairs.

  12. Repair of UV-irradiated plasmid DNA in excision repair deficient mutants of Saccharomyces cerevisiae

    International Nuclear Information System (INIS)

    Ikai, K.; Tano, K.; Ohnishi, T.; Nozu, K.

    1985-01-01

    The repair of UV-irradiated DNA of plasmid YEp13 was studied in the incision defective strains by measurement of cell transformation frequency. In Saccharomyces cerevisiae, rad1,2,3 and 4 mutants could repair UV-damaged plasmid DNA. In Escherichia coli, uvrA mutant was unable to repair UV-damaged plasmid DNA; however, pretreatment of the plasmid with Micrococcus luteus endonuclease increased repair. It was concluded that all the mutations of yeast were probably limited only to the nuclear DNA. (author)

  13. A Novel Technique for Shape Feature Extraction Using Content Based Image Retrieval

    Directory of Open Access Journals (Sweden)

    Dhanoa Jaspreet Singh

    2016-01-01

    Full Text Available With the advent of technology and multimedia information, digital images are increasing very quickly. Various techniques are being developed to retrieve/search digital information or data contained in the image. Traditional Text Based Image Retrieval System is not plentiful. Since it is time consuming as it require manual image annotation. Also, the image annotation differs with different peoples. An alternate to this is Content Based Image Retrieval (CBIR system. It retrieves/search for image using its contents rather the text, keywords etc. A lot of exploration has been compassed in the range of Content Based Image Retrieval (CBIR with various feature extraction techniques. Shape is a significant image feature as it reflects the human perception. Moreover, Shape is quite simple to use by the user to define object in an image as compared to other features such as Color, texture etc. Over and above, if applied alone, no descriptor will give fruitful results. Further, by combining it with an improved classifier, one can use the positive features of both the descriptor and classifier. So, a tryout will be made to establish an algorithm for accurate feature (Shape extraction in Content Based Image Retrieval (CBIR. The main objectives of this project are: (a To propose an algorithm for shape feature extraction using CBIR, (b To evaluate the performance of proposed algorithm and (c To compare the proposed algorithm with state of art techniques.

  14. Repair of furocoumarin adducts in mammalian cells

    International Nuclear Information System (INIS)

    Zolan, M.E.; Smith, C.A.; Hanawalt, P.C.

    1984-01-01

    DNA repair was studied in cultured mammalian cells treated with the furocoumarins 8-methoxypsoralen (8-MOP), aminomethyl trioxsalen, or angelicin and irradiated with near UV light. The amount of DNA cross-linked by 8-MOP in normal human cells decreased by about one-half in 24 hours after treatment; no decrease was observed in xeroderma pigmentosum cells, group A. At present, it is not known to what extent this decrease represents complete repair events at the sites of cross-links. Furocoumarin adducts elicited excision repair in normal human and monkey cells but not in xeroderma pigmentosum group A cells. This excision repair resembled in several aspects that elicited by pyrimidine dimers, formed in DNA by irradiation with 254-nm UV light; however, it appeared that for at least 8-MOP and aminomethyl trioxsalen, removal of adducts was not as efficient as was the removal of pyrimidine dimers. A comparison was also made of repair in the 172-base-pair repetitive alpha-DNA component of monkey cells to repair in the bulk of the genome. Although repair elicited by pyrimidine dimers in alpha-DNA was the same as in the bulk DNA, that following treatment of cells with either aminomethyl trioxsalen or angelicin and near UV was markedly deficient in alpha-DNA. This deficiency reflected the removal of fewer adducts from alpha-DNA after the same initial adduct frequencies. These results could mean that each furocoumarin may produce several structurally distinct adducts to DNA in cells and that the capacity of cellular repair systems to remove these various adducts may vary greatly

  15. Advanced repair methods for enhanced reactor safety

    International Nuclear Information System (INIS)

    Kornfeldt, H.

    1993-01-01

    A few innovative concepts are described of the ABB Atom Service Division for repair and mitigation techniques for primary systems in nuclear power plants. The concepts are based on Shape Memory Alloy (SMA) technology. A basic feature of all methods is that welding and component replacement is being avoided and the radiation dose imposed on maintenance personnel reduced. The SMA-based repair methods give plant operators new ways to meet increased safety standards and rising maintenance costs. (Z.S.) 4 figs

  16. Histone displacement during nucleotide excision repair

    DEFF Research Database (Denmark)

    Dinant, C.; Bartek, J.; Bekker-Jensen, S.

    2012-01-01

    Nucleotide excision repair (NER) is an important DNA repair mechanism required for cellular resistance against UV light and toxic chemicals such as those found in tobacco smoke. In living cells, NER efficiently detects and removes DNA lesions within the large nuclear macromolecular complex called...... of histone variants and histone displacement (including nucleosome sliding). Here we review current knowledge, and speculate about current unknowns, regarding those chromatin remodeling activities that physically displace histones before, during and after NER....

  17. Nucleotide excision repair in differentiated cells

    Energy Technology Data Exchange (ETDEWEB)

    Wees, Caroline van der [Department of Toxicogenetics, Leiden University Medical Center, Leiden (Netherlands); Department of Cardiology, Leiden University Medical Center, Leiden (Netherlands); Jansen, Jacob [Department of Toxicogenetics, Leiden University Medical Center, Leiden (Netherlands); Vrieling, Harry [Department of Toxicogenetics, Leiden University Medical Center, Leiden (Netherlands); Laarse, Arnoud van der [Department of Cardiology, Leiden University Medical Center, Leiden (Netherlands); Zeeland, Albert van [Department of Toxicogenetics, Leiden University Medical Center, Leiden (Netherlands); Mullenders, Leon [Department of Toxicogenetics, Leiden University Medical Center, Leiden (Netherlands)]. E-mail: l.mullenders@lumc.nl

    2007-01-03

    Nucleotide excision repair (NER) is the principal pathway for the removal of a wide range of DNA helix-distorting lesions and operates via two NER subpathways, i.e. global genome repair (GGR) and transcription-coupled repair (TCR). Although detailed information is available on expression and efficiency of NER in established mammalian cell lines, little is known about the expression of NER pathways in (terminally) differentiated cells. The majority of studies in differentiated cells have focused on repair of UV-induced cyclobutane pyrimidine dimers (CPD) and 6-4-photoproducts (6-4PP) because of the high frequency of photolesions at low level of toxicity and availability of sensitive technologies to determine photolesions in defined regions of the genome. The picture that emerges from these studies is blurred and rather complex. Fibroblasts and terminally differentiated myocytes of the rat heart display equally efficient GGR of 6-4PP but poor repair of CPD due to the absence of p48 expression. This repair phenotype is clearly different from human terminal differentiated neurons. Furthermore, both cell types were found to carry out TCR of CPD, thus mimicking the repair phenotype of established rodent cell lines. In contrast, in intact rat spermatogenic cells repair was very inefficient at the genome overall level and in transcriptionally active genes indicating that GGR and TCR are non-functional. Also, non-differentiated mouse embryonic stem (ES) cells exhibit low levels of NER after UV irradiation. However, the mechanisms that lead to low NER activity are clearly different: in differentiated spermatogenic cells differences in chromatin compaction and sequestering of NER proteins may underlie the lack of NER activity in pre-meiotic cells, whereas in non-differentiated ES cells NER is impaired by a strong apoptotic response.

  18. Success of Meniscal Repair at ACL Reconstruction

    Science.gov (United States)

    Toman, Charles; Spindler, Kurt P.; Dunn, Warren R.; Amendola, Annunziata; Andrish, Jack T.; Bergfeld, John A.; Flanigan, David; Jones, Morgan; Kaeding, Christopher C.; Marx, Robert G.; Matava, Matthew J.; McCarty, Eric C.; Parker, Richard D.; Wolcott, Michelle; Vidal, Armando; Wolf, Brian R.; Huston, Laura J.; Harrell, Frank E.; Wright, Rick W.

    2013-01-01

    Background Meniscal repair is performed in an attempt to prevent posttraumatic arthritis resulting from meniscal dysfunction after meniscal tears. The socioeconomic implications of premature arthritis are significant in the young patient population. Investigations and techniques focusing on meniscus preservation and healing are now at the forefront of orthopaedic sports medicine. Hypothesis Concomitant meniscal repair with ACL reconstruction is a durable and successful procedure at two year follow-up. Study Design Case Series; Level of evidence, 4. Methods All unilateral primary ACL reconstructions entered in 2002 in a prospective cohort who had meniscal repair at the time of ACLR were evaluated. Validated patient oriented outcome instruments were completed preoperatively and then again at the two-year postoperative time point. Reoperation after the index procedure was also documented and confirmed by operative reports. Results 437 unilateral primary ACL reconstructions were performed with 86 concomitant meniscal repairs (57 medial, 29 lateral) in 84 patients during the study period. Patient follow-up was obtained on 94% (81/86) of the meniscal repairs, allowing confirmation of meniscal repair success (defined as no repeat arthroscopic procedure) or failure. The overall success rate for meniscal repairs was 96% (76/79 patients) at two-year follow-up. Conclusions Meniscal repair is a successful procedure in conjunction with ACL reconstruction. When confronted with a “repairable” meniscal tear at the time of ACL reconstruction, orthopaedic surgeons can expect an estimated >90% clinical success rate at two-year follow-up using a variety of methods as shown in our study. PMID:19465734

  19. Dysphagia in children with repaired oesophageal atresia

    OpenAIRE

    Coppens, C.H.; Engel-Hoek, L. van den; Scharbatke, H.E.; Groot, S.A. de; Draaisma, J.M.T.

    2016-01-01

    Dysphagia is a common problem in children with repaired oesophageal atresia (OA). Abnormalities in the oropharyngeal and oesophageal phase have hardly been studied. The aims of this study were to assess the prevalence of dysphagia in children with repaired OA and to identify and differentiate oral and pharyngeal dysphagia based on videofluoroscopic swallow study (VFSS) findings in a limited number of children in this cohort. Medical records of 111 patients, born between January 1996 and July ...

  20. Inspection and repair of nuclear components

    International Nuclear Information System (INIS)

    Lahner, K.; Poetz, F.

    1993-01-01

    Despite careful design, manufacturing and operation, some of the important safety-relevant components show deterioration with time. Because of activation and contamination of these components, their inspection and repair has to be performed with manipulators. Some sophisticated manipulators are described, built by ABB Reaktor and used for inspection, maintenance and repair of PWR steam generators, fuel alignment pins, core baffle former bolts and reactor pressure vessel head penetrations. (Z.S.) 7 figs

  1. Studies on maternal repair in Drosophila melanogaster

    International Nuclear Information System (INIS)

    Mendelson, D.

    1976-01-01

    The work reported in this thesis is mainly concerned with studies on the nature of the repair mechanism(s) operating in Drosophila oocytes, and which act on chromosome damage induced by X-irradiation of post-meiotic male germ-cells. Caffeine treatment of the females has been used as an analytical tool to gain an insight into the nature of this repair mechanism and its genetic basis

  2. Value maximizing maintenance policies under general repair

    International Nuclear Information System (INIS)

    Marais, Karen B.

    2013-01-01

    One class of maintenance optimization problems considers the notion of general repair maintenance policies where systems are repaired or replaced on failure. In each case the optimality is based on minimizing the total maintenance cost of the system. These cost-centric optimizations ignore the value dimension of maintenance and can lead to maintenance strategies that do not maximize system value. This paper applies these ideas to the general repair optimization problem using a semi-Markov decision process, discounted cash flow techniques, and dynamic programming to identify the value-optimal actions for any given time and system condition. The impact of several parameters on maintenance strategy, such as operating cost and revenue, system failure characteristics, repair and replacement costs, and the planning time horizon, is explored. This approach provides a quantitative basis on which to base maintenance strategy decisions that contribute to system value. These decisions are different from those suggested by traditional cost-based approaches. The results show (1) how the optimal action for a given time and condition changes as replacement and repair costs change, and identifies the point at which these costs become too high for profitable system operation; (2) that for shorter planning horizons it is better to repair, since there is no time to reap the benefits of increased operating profit and reliability; (3) how the value-optimal maintenance policy is affected by the system's failure characteristics, and hence whether it is worthwhile to invest in higher reliability; and (4) the impact of the repair level on the optimal maintenance policy. -- Highlights: •Provides a quantitative basis for maintenance strategy decisions that contribute to system value. •Shows how the optimal action for a given condition changes as replacement and repair costs change. •Shows how the optimal policy is affected by the system's failure characteristics. •Shows when it is

  3. Accuracy of different imaging modalities prior to biventricular repair ...

    African Journals Online (AJOL)

    Internet Journal of Medical Update - EJOURNAL. Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives · Journal Home > Vol 11, No 1 (2016) >. Log in or Register to get access to full text downloads.

  4. An apology for primary repair of tetralogy of Fallot.

    Science.gov (United States)

    Van Arsdell, Glen; Yun, Tae-Jin

    2005-01-01

    The first repair of tetralogy of Fallot (TOF) was 50 years ago, so it would seem that the details for optimal management strategies would be clear. Timing of repair and operative repair strategy for TOF are still a source of debate. Varying institutions have published excellent outcomes with a primary repair strategy or a selective staged repair strategy. In this article, the current and historic strategy for repair of TOF at the Hospital for Sick Children in Toronto is delineated along with associated outcomes. Data from our institution indicate a clear survival advantage for primary repair of TOF.

  5. The Use of Extracorporeal Membrane Oxygenation in the Surgical Repair of Bronchial Rupture

    Directory of Open Access Journals (Sweden)

    Ju-Hee Park

    2016-02-01

    Full Text Available Extracorporeal membrane oxygenation (ECMO has been used successfully in critically ill patients with traumatic lung injury and offers an additional treatment modality. ECMO is mainly used as a bridge treatment to delayed surgical management; however, only a few case reports have presented the successful application of ECMO as intraoperative support during the surgical repair of traumatic bronchial injury. A 38-year-old man visited our hospital after a blunt chest trauma. His chest imaging showed hemopneumothorax in the left hemithorax and a finding suspicious for left main bronchus rupture. Bronchoscopy was performed and confirmed a tear in the left main bronchus and a congenital tracheal bronchus. We decided to provide venovenous ECMO support during surgery for bronchial repair. We successfully performed main bronchial repair in this traumatic patient with a congenital tracheal bronchus. We suggest that venovenous ECMO offers a good option for the treatment of bronchial rupture when adequate ventilation is not possible.

  6. Laparoscopic hernia repair and bladder injury.

    Science.gov (United States)

    Dalessandri, K M; Bhoyrul, S; Mulvihill, S J

    2001-01-01

    Bladder injury is a complication of laparoscopic surgery with a reported incidence in the general surgery literature of 0.5% and in the gynecology literature of 2%. We describe how to recognize and treat the injury and how to avoid the problem. We report two cases of bladder injury repaired with a General Surgical Interventions (GSI) trocar and a balloon device used for laparoscopic extraperitoneal inguinal hernia repair. One patient had a prior appendectomy; the other had a prior midline incision from a suprapubic prostatectomy. We repaired the bladder injury, and the patients made a good recovery. When using the obturator and balloon device, it is important to stay anterior to the preperitoneal space and bladder. Prior lower abdominal surgery can be considered a relative contraindication to extraperitoneal laparoscopic hernia repair. Signs of gas in the Foley bag or hematuria should alert the surgeon to a bladder injury. A one- or two-layer repair of the bladder injury can be performed either laparoscopically or openly and is recommended for a visible injury. Mesh repair of the hernia can be completed provided no evidence exists of urinary tract infection. A Foley catheter is placed until healing occurs.

  7. Human diseases associated with defective DNA repair

    International Nuclear Information System (INIS)

    Friedberg, E.C.; Ehmann, U.K.; Williams, J.I.

    1979-01-01

    The observations on xeroderma pigmentosum (XP) cells in culture were the first indications of defective DNA repair in association with human disease. Since then, a wealth of information on DNA repair in XP, and to a lesser extent in other diseases, has accumulated in the literature. Rather than clarifying the understanding of DNA repair mechanisms in normal cells and of defective DNA repair in human disease, the literature suggests an extraordinary complexity of both of the phenomena. In this review a number of discrete human diseases are considered separately. An attempt was made to systematically describe the pertinent clinical features and cellular and biochemical defects in these diseases, with an emphasis on defects in DNA metabolism, particularly DNA repair. Wherever possible observations have been correlated and unifying hypotheses presented concerning the nature of the basic defect(s) in these diseases. Discussions of the following diseases are presented: XP, ataxia telangiectasia; Fanconi's anemia; Hutchinson-Gilford progeria syndrome; Bloom's syndrome, Cockayne's syndrome; Down's syndrome; retinoblastoma; chronic lymphocytic leukemia; and other miscellaneous human diseases with possble DNA repair defects

  8. Repair of radiation damage in mammalian cells

    Energy Technology Data Exchange (ETDEWEB)

    Setlow, R.B.

    1981-01-01

    The responses, such as survival, mutation, and carcinogenesis, of mammalian cells and tissues to radiation are dependent not only on the magnitude of the damage to macromolecular structures - DNA, RNA, protein, and membranes - but on the rates of macromolecular syntheses of cells relative to the half-lives of the damages. Cells possess a number of mechanisms for repairing damage to DNA. If the repair systems are rapid and error free, cells can tolerate much larger doses than if repair is slow or error prone. It is important to understand the effects of radiation and the repair of radiation damage because there exist reasonable amounts of epidemiological data that permits the construction of dose-response curves for humans. The shapes of such curves or the magnitude of the response will depend on repair. Radiation damage is emphasized because: (a) radiation dosimetry, with all its uncertainties for populations, is excellent compared to chemical dosimetry; (b) a number of cancer-prone diseases are known in which there are defects in DNA repair and radiation results in more chromosomal damage in cells from such individuals than in cells from normal individuals; (c) in some cases, specific radiation products in DNA have been correlated with biological effects, and (d) many chemical effects seem to mimic radiation effects. A further reason for emphasizing damage to DNA is the wealth of experimental evidence indicating that damages to DNA can be initiating events in carcinogenesis.

  9. The forked flap repair for hypospadias

    Directory of Open Access Journals (Sweden)

    Anil Chadha

    2012-01-01

    Full Text Available Context: Despite the abundance of techniques for the repair of Hypospadias, its problems still persist and a satisfactory design to correct the penile curvature with the formation of neourethra from the native urethral tissue or genital or extragenital tissues, with minimal postoperative complications has yet to evolve. Aim: Persisting with such an endeavor, a new technique for the repair of distal and midpenile hypospadias is described. Materials and Methods: The study has been done in 70 cases over the past 11 years. The "Forked-Flap" repair is a single stage method for the repair of such Hypospadias with chordee. It takes advantage of the rich vascular communication at the corona and capitalizes on the established reliability of the meatal based flip-flap. The repair achieves straightening of the curvature of the penis by complete excision of chordee tissue from the ventral surface of the penis beneath the urethral plate. The urethra is reconstructed using the native plate with forked flap extensions and genital tissue relying on the concept of meatal based flaps. Water proofing by dartos tissue and reinforcement by Nesbit′s prepucial tissue transfer completes the one stage procedure. Statistical Analysis: An analysis of 70 cases of this single stage technique of repair of penile hypospadias with chordee, operated at 3 to 5 years of age over the past 11 years is presented. Results and Conclusion: The Forked Flap gives comparable and replicable results; except for a urethrocutaneous fistula rate of 4% no other complications were observed.

  10. Chitosan adhesive for laser tissue repair

    Science.gov (United States)

    Lauto, A.; Stoodley, M.; Avolio, A.; Foster, L. J. R.

    2006-02-01

    Background. Laser tissue repair usually relies on haemoderivate solders, based on serum albumin. These solders have intrinsic limitations that impair their widespread use, such as limited repair strength, high solubility, brittleness and viral transmission. Furthermore, the solder activation temperature (65-70 °C) can induce significant damage to tissue. In this study, a new laser-activated biomaterial for tissue repair was developed and tested in vitro and in vivo to overcome some of the shortcomings of traditional solders. Materials and Methods. Flexible and insoluble strips of chitosan adhesive (surface area ~34 mm2, thickness ~20 μm) were developed and bonded on sheep intestine with a laser fluence and irradiance of 52 +/- 2 J/cm2 and ~15 W/cm2 respectively. The temperature between tissue and adhesive was measured using small thermocouples. The strength of repaired tissue was tested by a calibrated tensiometer. The adhesive was also bonded in vivo to the sciatic nerve of rats to assess the thermal damage induced by the laser (fluence = 65 +/- 11 J/cm2, irradiance = 15 W/cm2) four days post-operatively. Results. Chitosan adhesives successfully repaired intestine tissue, achieving a repair strength of 0.50 +/- 0.15 N (shear stress = 14.7 +/- 4.7 KPa, n=30) at a temperature of 60-65 °C. The laser caused demyelination of axons at the operated site; nevertheless, the myelinated axons retained their normal morphology proximally and distally.

  11. Regulatory Challenges for Cartilage Repair Technologies.

    Science.gov (United States)

    McGowan, Kevin B; Stiegman, Glenn

    2013-01-01

    In the United States, few Food and Drug Administration (FDA)-approved options exist for the treatment of focal cartilage and osteochondral lesions. Developers of products for cartilage repair face many challenges to obtain marketing approval from the FDA. The objective of this review is to discuss the necessary steps for FDA application and approval for a new cartilage repair product. FDA Guidance Documents, FDA Panel Meetings, scientific organization recommendations, and clinicaltrials.gov were reviewed to demonstrate the current thinking of FDA and the scientific community on the regulatory process for cartilage repair therapies. Cartilage repair therapies can receive market approval from FDA as medical devices, drugs, or biologics, and the specific classification of product can affect the nonclinical, clinical, and regulatory strategy to bring the product to market. Recent FDA guidance gives an outline of the required elements to bring a cartilage repair product to market, although these standards are often very general. As a result, companies have to carefully craft their study patient population, comparator group, and clinical endpoint to best showcase their product's attributes. In addition, regulatory strategy and manufacturing process validation need to be considered early in the clinical study process to allow for timely product approval following the completion of clinical study. Although the path to regulatory approval for a cartilage repair therapy is challenging and time-consuming, proper clinical trial planning and attention to the details can eventually save companies time and money by bringing a product to the market in the most expeditious process possible.

  12. Repair of radiation damage in mammalian cells

    International Nuclear Information System (INIS)

    Setlow, R.B.

    1981-01-01

    The responses, such as survival, mutation, and carcinogenesis, of mammalian cells and tissues to radiation are dependent not only on the magnitude of the damage to macromolecular structures - DNA, RNA, protein, and membranes - but on the rates of macromolecular syntheses of cells relative to the half-lives of the damages. Cells possess a number of mechanisms for repairing damage to DNA. If the repair systems are rapid and error free, cells can tolerate much larger doses than if repair is slow or error prone. It is important to understand the effects of radiation and the repair of radiation damage because there exist reasonable amounts of epidemiological data that permits the construction of dose-response curves for humans. The shapes of such curves or the magnitude of the response will depend on repair. Radiation damage is emphasized because: (a) radiation dosimetry, with all its uncertainties for populations, is excellent compared to chemical dosimetry; (b) a number of cancer-prone diseases are known in which there are defects in DNA repair and radiation results in more chromosomal damage in cells from such individuals than in cells from normal individuals; (c) in some cases, specific radiation products in DNA have been correlated with biological effects, and (d) many chemical effects seem to mimic radiation effects. A further reason for emphasizing damage to DNA is the wealth of experimental evidence indicating that damages to DNA can be initiating events in carcinogenesis

  13. Clinical outcomes and repair integrity after arthroscopic full-thickness rotator cuff repair: suture-bridge versus double-row modified Mason-Allen technique.

    Science.gov (United States)

    Lee, Kwang Won; Yang, Dae Suk; Lee, Gyu Sang; Ma, Chang Hyun; Choy, Won Sik

    2018-05-23

    This retrospective study compared the clinical and radiologic outcomes of patients who underwent arthroscopic rotator cuff repairs by the suture-bridge and double-row modified Mason-Allen techniques. From January 2012 to May 2013, 76 consecutive cases of full-thickness rotator cuff tear, 1 to 4 cm in the sagittal plane, for which arthroscopic rotator cuff repair was performed, were included. The suture-bridge technique was used in 37 consecutive shoulders; and the double-row modified Mason-Allen technique, in 39 consecutive shoulders. Clinical outcomes at a minimum of 2 years (mean, 35.7 months) were evaluated postoperatively using the visual analog scale; University of California, Los Angeles Shoulder Scale; American Shoulder and Elbow Surgeons Subjective Shoulder Scale; and Constant score. Postoperative cuff integrity was evaluated at a mean of 17.7 months by magnetic resonance imaging. At the final follow-up, the clinical outcomes improved in both groups (all P  .05). The retear rate was 18.9% in the shoulders subjected to suture-bridge repair and 12.8% in the double-row modified Mason-Allen group; the difference was not significant (P = .361). Despite the presence of fewer suture anchors, the patients who underwent double-row modified Mason-Allen repair had comparable shoulder functional outcomes and a comparable retear rate with those who underwent suture-bridge repair. Therefore, the double-row modified Mason-Allen repair technique can be considered an effective treatment for patients with medium- to large-sized full-thickness rotator cuff tears. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  14. Virtual Modeling for Cities of the Future. State-Of Art and Virtual Modeling for Cities of the Future. State-Of Art AN

    Science.gov (United States)

    Valencia, J.; Muñoz-Nieto, A.; Rodriguez-Gonzalvez, P.

    2015-02-01

    3D virtual modeling, visualization, dissemination and management of urban areas is one of the most exciting challenges that must face geomatics in the coming years. This paper aims to review, compare and analyze the new technologies, policies and software tools that are in progress to manage urban 3D information. It is assumed that the third dimension increases the quality of the model provided, allowing new approaches to urban planning, conservation and management of architectural and archaeological areas. Despite the fact that displaying 3D urban environments is an issue nowadays solved, there are some challenges to be faced by geomatics in the coming future. Displaying georeferenced linked information would be considered the first challenge. Another challenge to face is to improve the technical requirements if this georeferenced information must be shown in real time. Are there available software tools ready for this challenge? Are they useful to provide services required in smart cities? Throughout this paper, many practical examples that require 3D georeferenced information and linked data will be shown. Computer advances related to 3D spatial databases and software that are being developed to convert rendering virtual environment to a new enriched environment with linked information will be also analyzed. Finally, different standards that Open Geospatial Consortium has assumed and developed regarding the three-dimensional geographic information will be reviewed. Particular emphasis will be devoted on KML, LandXML, CityGML and the new IndoorGML.

  15. Phase-contrast MR assessment of pulmonary venous blood flow in children with surgically repaired pulmonary veins

    International Nuclear Information System (INIS)

    Valsangiacomo, Emanuela R.; Yoo, Shi-Joon; Barrea, Catherine; Smallhorn, Jeffrey F.; Macgowan, Christopher K.; Coles, John G.

    2003-01-01

    Pulmonary venous (PV) obstruction may complicate surgical repair of PV abnormalities. By combining phase-contrast cine (PC) imaging and contrast-enhanced angiography, magnetic resonance (MR) imaging can provide physiological information complementing anatomical diagnosis. To compare the PV flow pattern observed after surgical repair of PV abnormalities with normal PV flow pattern and to investigate the changes occurring in the presence of PV stenosis by using PC MR in children. By using PC MR, PV flow was evaluated in 14 patients (3 months-14 years) who underwent surgical repair for PV abnormalities. Eleven children (8-18 years) were studied as normal controls. Peak flow velocities and patterns were compared among three groups: normal veins (n=23), surgically repaired veins without (n=44) and with stenosis (n=10). Normal and unobstructed pulmonary veins after surgery showed a biphasic or triphasic flow pattern with one or two systolic peaks and a diastolic peak. Unobstructed surgically repaired veins showed decreased peak systolic velocity (P =0.001) and an increased peak diastolic velocity (P=0.005) when compared to normal values. Obstructed veins showed decreased systolic and diastolic velocities when measured upstream from the stenosis. PC MR shows different flow patterns among normal, surgically repaired pulmonary veins with and without stenosis. (orig.)

  16. Arthroscopic repair of massive contracted rotator cuff tears: aggressive release with anterior and posterior interval slides do not improve cuff healing and integrity.

    Science.gov (United States)

    Kim, Sung-Jae; Kim, Sung-Hwan; Lee, Su-Keon; Seo, Jae-Wan; Chun, Yong-Min

    2013-08-21

    Few studies of large-to-massive contracted rotator cuff tears have examined the arthroscopic complete repair obtained by a posterior interval slide and whether the clinical outcomes or structural integrity achieved are better than those after partial repair without the posterior interval slide. The study included forty-one patients with large-to-massive contracted rotator cuff tears, not amenable to complete repair with margin convergence alone. The patients underwent either arthroscopic complete repair with a posterior interval slide and side-to-side repair of the interval slide edge (twenty-two patients; Group P) or partial repair with margin convergence (nineteen patients; Group M). The patient assignment was not randomized. The Simple Shoulder Test (SST), American Shoulder and Elbow Surgeons (ASES) score, University of California at Los Angeles (UCLA) shoulder score, and range of motion were used to compare the functional outcomes. Preoperative and six-month postoperative magnetic resonance arthrography (MRA) images were compared within or between groups. At the two-year follow-up evaluation, the SST, ASES score, UCLA score, and range of motion had significantly improved (p repair group with an aggressive release had no better clinical or structural outcomes compared with the partial repair group with margin convergence alone for large-to-massive contracted rotator cuff tears. In addition, the complete repair group had a 91% retear rate and a greater defect on follow-up MRA images. Even though this study had a relatively short-term follow-up, a complete repair of large-to-massive contracted rotator cuff tears, with an aggressive release such as posterior interval slide, may not have an increased benefit compared with partial repair without posterior interval slide.

  17. Early Cleft Lip Repair Revisited: A Safe and Effective Approach Utilizing a Multidisciplinary Protocol.

    Science.gov (United States)

    Hammoudeh, Jeff A; Imahiyerobo, Thomas A; Liang, Fan; Fahradyan, Artur; Urbinelli, Leo; Lau, Jennifer; Matar, Marla; Magee, William; Urata, Mark

    2017-06-01

    The optimal timing for cleft lip repair has yet to be established. Advances in neonatal anesthesia, along with a growing body of literature, suggesting benefits of earlier cleft lip and nasal repair, have set the stage for a reexamination of current practices. In this prospective study, cleft lip and nasal repair occurred on average at 34.8 days (13-69 days). Nasal correction was achieved primarily through molding the nasal cartilage without the placement of nasal sutures at the time of repair. A standardized anesthetic protocol aimed at limiting neurotoxicity was utilized in all cases. Anesthetic and postoperative complications were assessed. A 3-dimensional nasal analysis compared pre- and postoperative nasal symmetry for unilateral clefts. Surveys assessed familial response to repair. Thirty-two patients were included (27 unilateral and 5 bilateral clefts). In this study, the overall complication rate was 3.1%. Anthropometric measurements taken from 3-dimensional-image models showed statistically significant improvement in ratios of nostril height (preoperative mean, 0.59; postoperative mean, 0.80), nasal base width (preoperative mean, 1.96; postoperative mean, 1.12), columella length (preoperative mean, 0.62; postoperative mean, 0.89; and columella angle (preoperative mean, 30.73; postoperative mean, 9.1). Survey data indicated that families uniformly preferred earlier repair. We present evidence that early cleft lip and nasal repair can be performed safely and is effective at improving nasal symmetry without the placement of any nasal sutures. Utilization of this protocol has the potential to be a paradigm shift in the treatment of cleft lip and nasal deformity.

  18. Diffuse myocardial fibrosis following tetralogy of Fallot repair: a T1 mapping cardiac magnetic resonance study

    International Nuclear Information System (INIS)

    Kozak, Marcelo F.; Yoo, Shi-Joon; Seed, Mike; Grosse-Wortmann, Lars; Redington, Andrew; Greiser, Andreas

    2014-01-01

    Adverse ventricular remodeling after tetralogy of Fallot (TOF) repair is associated with diffuse myocardial fibrosis. The goal of this study was to measure post-contrast myocardial T1 in pediatric patients after TOF repair as surrogates of myocardial fibrosis. Children after TOF repair who underwent cardiac magnetic resonance imaging with T1 mapping using the modified look-locker inversion recovery (MOLLI) sequence were included. In addition to routine volumetric and flow data, we measured post-contrast T1 values of the basal interventricular septum, the left ventricular (LV) lateral wall, and the inferior and anterior walls of the right ventricle (RV). Results were compared to data from age-matched healthy controls. The scans of 18 children who had undergone TOF repair and 12 healthy children were included. Post-contrast T1 values of the left ventricular lateral wall (443 ± 54 vs. 510 ± 77 ms, P = 0.0168) and of the right ventricular anterior wall (333 ± 62 vs. 392 ± 72 ms, P = 0.0423) were significantly shorter in children with TOF repair than in controls, suggesting a higher degree of fibrosis. In children with TOF repair, but not in controls, post-contrast T1 values were shorter in the right ventricle than the left ventricle and shorter in the anterior wall of the right ventricle than in the inferior segments. In the TOF group, post-contrast T1 values of the RV anterior wall correlated with the RV end-systolic volume indexed to body surface area (r = 0.54; r 2 = 0.30; P = 0.0238). In children who underwent tetralogy of Fallot repair the myocardium of both ventricles appears to bear an abnormally high fibrosis burden. (orig.)

  19. Defective bone repair in mast cell-deficient Cpa3Cre/+ mice.

    Directory of Open Access Journals (Sweden)

    Jose Luis Ramirez-GarciaLuna

    Full Text Available In the adult skeleton, cells of the immune system interact with those of the skeleton during all phases of bone repair to influence the outcome. Mast cells are immune cells best known for their pathologic role in allergy, and may be involved in chronic inflammatory and fibrotic disorders. Potential roles for mast cells in tissue homeostasis, vascularization and repair remain enigmatic. Previous studies in combined mast cell- and Kit-deficient KitW-sh/W-sh mice (KitW-sh implicated mast cells in bone repair but KitW-sh mice suffer from additional Kit-dependent hematopoietic and non- hematopoietic deficiencies that could have confounded the outcome. The goal of the current study was to compare bone repair in normal wild type (WT and Cpa3Cre/+ mice, which lack mast cells in the absence of any other hematopoietic or non- hematopoietic deficiencies. Repair of a femoral window defect was characterized using micro CT imaging and histological analyses from the early inflammatory phase, through soft and hard callus formation, and finally the remodeling phase. The data indicate 1 mast cells appear in healing bone of WT mice but not Cpa3Cre/+ mice, beginning 14 days after surgery; 2 re-vascularization of repair tissue and deposition of mineralized bone was delayed and dis-organised in Cpa3Cre/+ mice compared with WT mice; 3 the defects in Cpa3Cre/+ mice were associated with little change in anabolic activity and biphasic alterations in osteoclast and macrophage activity. The outcome at 56 days postoperative was complete bridging of the defect in most WT mice and fibrous mal-union in most Cpa3Cre/+ mice. The results indicate that mast cells promote bone healing, possibly by recruiting vascular endothelial cells during the inflammatory phase and coordinating anabolic and catabolic activity during tissue remodeling. Taken together the data indicate that mast cells have a positive impact on bone repair.

  20. Defective bone repair in mast cell-deficient Cpa3Cre/+ mice.

    Science.gov (United States)

    Ramirez-GarciaLuna, Jose Luis; Chan, Daniel; Samberg, Robert; Abou-Rjeili, Mira; Wong, Timothy H; Li, Ailian; Feyerabend, Thorsten B; Rodewald, Hans-Reimer; Henderson, Janet E; Martineau, Paul A

    2017-01-01

    In the adult skeleton, cells of the immune system interact with those of the skeleton during all phases of bone repair to influence the outcome. Mast cells are immune cells best known for their pathologic role in allergy, and may be involved in chronic inflammatory and fibrotic disorders. Potential roles for mast cells in tissue homeostasis, vascularization and repair remain enigmatic. Previous studies in combined mast cell- and Kit-deficient KitW-sh/W-sh mice (KitW-sh) implicated mast cells in bone repair but KitW-sh mice suffer from additional Kit-dependent hematopoietic and non- hematopoietic deficiencies that could have confounded the outcome. The goal of the current study was to compare bone repair in normal wild type (WT) and Cpa3Cre/+ mice, which lack mast cells in the absence of any other hematopoietic or non- hematopoietic deficiencies. Repair of a femoral window defect was characterized using micro CT imaging and histological analyses from the early inflammatory phase, through soft and hard callus formation, and finally the remodeling phase. The data indicate 1) mast cells appear in healing bone of WT mice but not Cpa3Cre/+ mice, beginning 14 days after surgery; 2) re-vascularization of repair tissue and deposition of mineralized bone was delayed and dis-organised in Cpa3Cre/+ mice compared with WT mice; 3) the defects in Cpa3Cre/+ mice were associated with little change in anabolic activity and biphasic alterations in osteoclast and macrophage activity. The outcome at 56 days postoperative was complete bridging of the defect in most WT mice and fibrous mal-union in most Cpa3Cre/+ mice. The results indicate that mast cells promote bone healing, possibly by recruiting vascular endothelial cells during the inflammatory phase and coordinating anabolic and catabolic activity during tissue remodeling. Taken together the data indicate that mast cells have a positive impact on bone repair.

  1. Diffuse myocardial fibrosis following tetralogy of Fallot repair: a T1 mapping cardiac magnetic resonance study

    Energy Technology Data Exchange (ETDEWEB)

    Kozak, Marcelo F.; Yoo, Shi-Joon; Seed, Mike; Grosse-Wortmann, Lars [The Hospital for Sick Children, University of Toronto, Labatt Family Heart Centre in the Department of Paediatrics and Department of Diagnostic Imaging, Toronto (Canada); Redington, Andrew [The Hospital for Sick Children, University of Toronto, Labatt Family Heart Centre in the Department of Paediatrics, Toronto (Canada); Greiser, Andreas [Siemens AG Healthcare Sector, Erlangen (Germany)

    2014-04-15

    Adverse ventricular remodeling after tetralogy of Fallot (TOF) repair is associated with diffuse myocardial fibrosis. The goal of this study was to measure post-contrast myocardial T1 in pediatric patients after TOF repair as surrogates of myocardial fibrosis. Children after TOF repair who underwent cardiac magnetic resonance imaging with T1 mapping using the modified look-locker inversion recovery (MOLLI) sequence were included. In addition to routine volumetric and flow data, we measured post-contrast T1 values of the basal interventricular septum, the left ventricular (LV) lateral wall, and the inferior and anterior walls of the right ventricle (RV). Results were compared to data from age-matched healthy controls. The scans of 18 children who had undergone TOF repair and 12 healthy children were included. Post-contrast T1 values of the left ventricular lateral wall (443 ± 54 vs. 510 ± 77 ms, P = 0.0168) and of the right ventricular anterior wall (333 ± 62 vs. 392 ± 72 ms, P = 0.0423) were significantly shorter in children with TOF repair than in controls, suggesting a higher degree of fibrosis. In children with TOF repair, but not in controls, post-contrast T1 values were shorter in the right ventricle than the left ventricle and shorter in the anterior wall of the right ventricle than in the inferior segments. In the TOF group, post-contrast T1 values of the RV anterior wall correlated with the RV end-systolic volume indexed to body surface area (r = 0.54; r{sup 2} = 0.30; P = 0.0238). In children who underwent tetralogy of Fallot repair the myocardium of both ventricles appears to bear an abnormally high fibrosis burden. (orig.)

  2. DNA Damage Induced by Alkylating Agents and Repair Pathways

    OpenAIRE

    Natsuko Kondo; Akihisa Takahashi; Koji Ono; Takeo Ohnishi

    2010-01-01

    The cytotoxic effects of alkylating agents are strongly attenuated by cellular DNA repair processes, necessitating a clear understanding of the repair mechanisms. Simple methylating agents form adducts at N- and O-atoms. N-methylations are removed by base excision repair, AlkB homologues, or nucleotide excision repair (NER). O 6-methylguanine (MeG), which can eventually become cytotoxic and mutagenic, is repaired by O 6-methylguanine-DNA methyltransferase, and O 6MeG:T mispairs are recognized...

  3. The relationship of transcription and repair of radioinduced DNA damage

    International Nuclear Information System (INIS)

    Zhestyanikov, V.D.; Igusheva, O.A.

    1997-01-01

    The data are discussed which has become a basement of such important findings as involvement of transcription into repair or existence of transcription-coupling repair factors. Thymine glycols which are appear under ionizing radiation exposure, are repaired preferentially in transcribed DNA. In present review the preferential repair of ionizing radiation-induced singlestrand breaks (SSBa) in transcribed DNA of human cells. Discontinuous distribution of DNA repair along hole genome has a grate role in biological processes

  4. Earlier Pulmonary Valve Replacement in Down Syndrome Patients Following Tetralogy of Fallot Repair.

    Science.gov (United States)

    Sullivan, Rachel T; Frommelt, Peter C; Hill, Garick D

    2017-08-01

    The association between Down syndrome and pulmonary hypertension could contribute to more severe pulmonary regurgitation after tetralogy of Fallot repair and possibly earlier pulmonary valve replacement. We compared cardiac magnetic resonance measures of pulmonary regurgitation and right ventricular dilation as well as timing of pulmonary valve replacement between those with and without Down syndrome after tetralogy of Fallot repair. Review of our surgical database from 2000 to 2015 identified patients with tetralogy of Fallot with pulmonary stenosis. Those with Down syndrome were compared to those without. The primary outcome of interest was time from repair to pulmonary valve replacement. Secondary outcomes included pulmonary regurgitation and indexed right ventricular volume on cardiac magnetic resonance imaging. The cohort of 284 patients included 35 (12%) with Down syndrome. Transannular patch repair was performed in 210 (74%). Down syndrome showed greater degree of pulmonary regurgitation (55 ± 14 vs. 37 ± 16%, p = 0.01) without a significantly greater rate of right ventricular dilation (p = 0.09). In multivariable analysis, Down syndrome (HR 2.3, 95% CI 1.2-4.5, p = 0.02) and transannular patch repair (HR 5.5, 95% CI 1.7-17.6, p = 0.004) were significant risk factors for valve replacement. Those with Down syndrome had significantly lower freedom from valve replacement (p = 0.03). Down syndrome is associated with an increased degree of pulmonary regurgitation and earlier pulmonary valve replacement after tetralogy of Fallot repair. These patients require earlier assessment by cardiac magnetic resonance imaging to determine timing of pulmonary valve replacement and evaluation for and treatment of preventable causes of pulmonary hypertension.

  5. Advantages of Arthroscopic Rotator Cuff Repair With a Transosseous Suture Technique: A Prospective Randomized Controlled Trial.

    Science.gov (United States)

    Randelli, Pietro; Stoppani, Carlo Alberto; Zaolino, Carlo; Menon, Alessandra; Randelli, Filippo; Cabitza, Paolo

    2017-07-01

    Rotator cuff tear is a common finding in patients with painful, poorly functioning shoulders. The surgical management of this disorder has improved greatly and can now be fully arthroscopic. To evaluate clinical and radiological results of arthroscopic rotator cuff repair using 2 different techniques: single-row anchor fixation versus transosseous hardware-free suture repair. Randomized controlled trial; Level of evidence, 1. Sixty-nine patients with rotator cuff tears were enrolled: 35 patients were operated with metal anchors and 34 with standardized transosseous repair. The patients were clinically evaluated before surgery, during the 28 days after surgery, and at least 1 year after the operation by the use of validated rating scores (Constant score, QuickDASH, and numerical rating scale [NRS]). Final follow-up was obtained at more than 3 years by a QuickDASH evaluation to detect any difference from the previous follow-up. During the follow-up, rotator cuff integrity was determined through magnetic resonance imaging and was classified according to the 5 Sugaya categories. Patients operated with the transosseous technique had significantly less pain, especially from the 15th postoperative day: In the third week, the mean NRS value for the anchor group was 3.00 while that for transosseous group was 2.46 ( P = .02); in the fourth week, the values were 2.44 and 1.76, respectively ( P rotator cuff repair integrity, based on Sugaya magnetic resonance imaging classification, no significant difference was found between the 2 techniques in terms of retear rate ( P = .81). No significant differences were found between the 2 arthroscopic repair techniques in terms of functional and radiological results. However, postoperative pain decreased more quickly after the transosseous procedure, which therefore emerges as a possible improvement in the surgical repair of the rotator cuff. Registration: NCT01815177 ( ClinicalTrials.gov identifier).

  6. AMISS - Active and passive MIcrowaves for Security and Subsurface imaging

    Science.gov (United States)

    Soldovieri, Francesco; Slob, Evert; Turk, Ahmet Serdar; Crocco, Lorenzo; Catapano, Ilaria; Di Matteo, Francesca

    2013-04-01

    The FP7-IRSES project AMISS - Active and passive MIcrowaves for Security and Subsurface imaging is based on a well-combined network among research institutions of EU, Associate and Third Countries (National Research Council of Italy - Italy, Technische Universiteit Delft - The Netherlands, Yildiz Technical University - Turkey, Bauman Moscow State Technical University - Russia, Usikov Institute for Radio-physics and Electronics and State Research Centre of Superconductive Radioelectronics "Iceberg" - Ukraine and University of Sao Paulo - Brazil) with the aims of achieving scientific advances in the framework of microwave and millimeter imaging systems and techniques for security and safety social issues. In particular, the involved partners are leaders in the scientific areas of passive and active imaging and are sharing their complementary knowledge to address two main research lines. The first one regards the design, characterization and performance evaluation of new passive and active microwave devices, sensors and measurement set-ups able to mitigate clutter and increase information content. The second line faces the requirements to make State-of-the-Art processing tools compliant with the instrumentations developed in the first line, suitable to work in electromagnetically complex scenarios and able to exploit the unexplored possibilities offered by new instrumentations. The main goals of the project are: 1) Development/improvement and characterization of new sensors and systems for active and passive microwave imaging; 2) Set up, analysis and validation of state of art/novel data processing approach for GPR in critical infrastructure and subsurface imaging; 3) Integration of state of art and novel imaging hardware and characterization approaches to tackle realistic situations in security, safety and subsurface prospecting applications; 4) Development and feasibility study of bio-radar technology (system and data processing) for vital signs detection and

  7. Repairable-conditionally repairable damage model based on dual Poisson processes.

    Science.gov (United States)

    Lind, B K; Persson, L M; Edgren, M R; Hedlöf, I; Brahme, A

    2003-09-01

    The advent of intensity-modulated radiation therapy makes it increasingly important to model the response accurately when large volumes of normal tissues are irradiated by controlled graded dose distributions aimed at maximizing tumor cure and minimizing normal tissue toxicity. The cell survival model proposed here is very useful and flexible for accurate description of the response of healthy tissues as well as tumors in classical and truly radiobiologically optimized radiation therapy. The repairable-conditionally repairable (RCR) model distinguishes between two different types of damage, namely the potentially repairable, which may also be lethal, i.e. if unrepaired or misrepaired, and the conditionally repairable, which may be repaired or may lead to apoptosis if it has not been repaired correctly. When potentially repairable damage is being repaired, for example by nonhomologous end joining, conditionally repairable damage may require in addition a high-fidelity correction by homologous repair. The induction of both types of damage is assumed to be described by Poisson statistics. The resultant cell survival expression has the unique ability to fit most experimental data well at low doses (the initial hypersensitive range), intermediate doses (on the shoulder of the survival curve), and high doses (on the quasi-exponential region of the survival curve). The complete Poisson expression can be approximated well by a simple bi-exponential cell survival expression, S(D) = e(-aD) + bDe(-cD), where the first term describes the survival of undamaged cells and the last term represents survival after complete repair of sublethal damage. The bi-exponential expression makes it easy to derive D(0), D(q), n and alpha, beta values to facilitate comparison with classical cell survival models.

  8. Land-use Scene Classification in High-Resolution Remote Sensing Images by Multiscale Deeply Described Correlatons

    Science.gov (United States)

    Qi, K.; Qingfeng, G.

    2017-12-01

    With the popular use of High-Resolution Satellite (HRS) images, more and more research efforts have been placed on land-use scene classification. However, it makes the task difficult with HRS images for the complex background and multiple land-cover classes or objects. This article presents a multiscale deeply described correlaton model for land-use scene classification. Specifically, the convolutional neural network is introduced to learn and characterize the local features at different scales. Then, learnt multiscale deep features are explored to generate visual words. The spatial arrangement of visual words is achieved through the introduction of adaptive vector quantized correlograms at different scales. Experiments on two publicly available land-use scene datasets demonstrate that the proposed model is compact and yet discriminative for efficient representation of land-use scene images, and achieves competitive classification results with the state-of-art methods.

  9. Combined laparoscopic and open technique for repair of congenital abdominal hernia: A case report of prune belly syndrome.

    Science.gov (United States)

    Ye, Qinghuang; Chen, Yan; Zhu, Jinhui; Wang, Yuedong

    2017-10-01

    Prune belly syndrome (PBS) is a rare congenital disorder among adults, and the way for repairing abdominal wall musculature has no unified standard. We described combining laparoscopic and open technique in an adult male who presented with PBS. Physical examination and radiological imaging verified the case of PBS. The deficiency of abdominal wall musculature was repaired by combining laparoscopic and open technique using a double-deck complex patch. The patient successfully underwent abdominal wall repair by combining laparoscopic and open technique. Postoperative recovery was uneventful, and improvement in symptom was significant in follow-up after 3, 6, 12, and 24 months. Combining laparoscopic and open technique for repair of deficiency of abdominal wall musculature in PBS was an exploratory way to improve life quality.

  10. Self-repair of cracks in brittle material systems

    Science.gov (United States)

    Dry, Carolyn M.

    2016-04-01

    One of the most effective uses for self repair is in material systems that crack because the cracks can allow the repair chemical to flow into the crack damage sites in all three dimensions. In order for the repair chemical to stay in the damage site and flow along to all the crack and repair there must be enough chemical to fill the entire crack. The repair chemical must be designed appropriately for the particular crack size and total volume of cracks. In each of the three examples of self repair in crackable brittle systems, the viscosity and chemical makeup and volume of the repair chemicals used is different for each system. Further the chemical delivery system has to be designed for each application also. Test results from self repair of three brittle systems are discussed. In "Self Repair of Concrete Bridges and Infrastructure" two chemicals were used due to different placements in bridges to repair different types of cracks- surface shrinkage and shear cracks, In "Airplane Wings and Fuselage, in Graphite" the composite has very different properties than the concrete bridges. In the graphite for airplane components the chemical also had to survive the high processing temperatures. In this composite the cracks were so definite and deep and thin that the repair chemical could flow easily and repair in all layers of the composite. In "Ceramic/Composite Demonstrating Self Repair" the self repair system not only repaired the broken ceramic but also rebounded the composite to the ceramic layer

  11. Energy and Technology Review: Unlocking the mysteries of DNA repair

    Energy Technology Data Exchange (ETDEWEB)

    Quirk, W.A.

    1993-04-01

    DNA, the genetic blueprint, has the remarkable property of encoding its own repair following diverse types of structural damage induced by external agents or normal metabolism. We are studying the interplay of DNA damaging agents, repair genes, and their protein products to decipher the complex biochemical pathways that mediate such repair. Our research focuses on repair processes that correct DNA damage produced by chemical mutagens and radiation, both ionizing and ultraviolet. The most important type of DNA repair in human cells is called excision repair. This multistep process removes damaged or inappropriate pieces of DNA -- often as a string of 29 nucleotides containing the damage -- and replaces them with intact ones. We have isolated, cloned, and mapped several human repair genes associated with the nucleotide excision repair pathway and involved in the repair of DNA damage after exposure to ultraviolet light or mutagens in cooked food. We have shown that a defect in one of these repair genes, ERCC2, is responsible for the repair deficiency in one of the groups of patients with the recessive genetic disorder xeroderma pigmentosum (XP group D). We are exploring ways to purify sufficient quantities (milligrams) of the protein products of these and other repair genes so that we can understand their functions. Our long-term goals are to link defective repair proteins to human DNA repair disorders that predispose to cancer, and to produce DNA-repair-deficient mice that can serve as models for the human disorders.

  12. [Rotator cuff repair: single- vs double-row. Clinical and biomechanical results].

    Science.gov (United States)

    Baums, M H; Kostuj, T; Klinger, H-M; Papalia, R

    2016-02-01

    The goal of rotator cuff repair is a high initial mechanical stability as a requirement for adequate biological recovery of the tendon-to-bone complex. Notwithstanding the significant increase in publications concerning the topic of rotator cuff repair, there are still controversies regarding surgical technique. The aim of this work is to present an overview of the recently published results of biomechanical and clinical studies on rotator cuff repair using single- and double-row techniques. The review is based on a selective literature research of PubMed, Embase, and the Cochrane Database on the subject of the clinical and biomechanical results of single- and double-row repair. In general, neither the biomechanical nor the clinical evidence can recommend the use of a double-row concept for the treatment for every rotator cuff tear. Only tears of more than 3 cm seem to benefit from better results on both imaging and in clinical outcome studies compared with the use of single-row techniques. Despite a significant increase in publications on the surgical treatment of rotator cuff tears in recent years, the clinical results were not significantly improved in the literature so far. Unique information and algorithms, from which the optimal treatment of this entity can be derived, are still inadequate. Because of the cost-effectiveness and the currently vague evidence, the double-row techniques cannot be generally recommended for the repair of all rotator cuff tears.

  13. Repair welding of cracked steam turbine blades

    International Nuclear Information System (INIS)

    Bhaduri, A.K.; Gill, T.P.S.; Albert, S.K.; Shanmugam, K.; Iyer, D.R.

    1999-01-01

    The procedure for repair welding of cracked steam turbine blades made of martensitic stainless steels has been developed using the gas tungsten arc welding process. Weld repair procedures were developed using both ER316L austenitic stainless steel filler wire and ER410 martensitic stainless steel filler wire. The repair welding procedure with austenitic filler wire was developed to avoid preheating of the blade as also hydrogen induced cold cracking, and involved evaluation of three different austenitic filler wires, viz. ER309L, ER316L and ERNiCr-3. The overall development of the repair welding procedure included selection of welding consumables (for austenitic filler metal), optimisation of post weld heat treatment parameters, selection of suitable method for local pre-heating and post-weld heat treatment (PWHT) of the blades, determination of mechanical properties of weldments in as-welded and PWHT conditions, and microstructural examination. After various trials using different procedures, the procedure of local PWHT using electrical resistance heating on the top surface of the weldment and monitoring the temperature by placing a thermocouple at the bottom of the weld, was found to give the most satisfactory results. A similar procedure was used for preheating while using ER410 filler metal. Mechanical testing of weldments before and after PWHT involved tensile tests at room temperature, face and root bend tests, and microhardness measurements across the fusion line and heat affected zone. During procedure qualification, mock-ups and actual repair welding, dye penetrant testing was used at different stages and where ever possible radiography was carried out. These procedures were developed for repair welding of cracked blades in the low-pressure (LP) steam turbines of Indian nuclear power plants. The procedure with ER316 L filler wire has so far been applied for repair welding of 2 cracked blades (made of AISI 410 SS) of LP steam turbines, while the procedure

  14. Pediatric hypertension: An approach to imaging

    International Nuclear Information System (INIS)

    Diament, M.J.; Stanley, P.; Gilsanz, V.; Boechat, M.I.; Kangarloo, H.; Lieberman, E.R.

    1986-01-01

    Since 1981, we have made diagnoses of secondary hypertension using state of art imaging equipment in 18 pediatric patients. The most valuable tests were ultrasound identifying renal parenchymal disease, computed body tomography for adrenal tumors and intra-arterial renal angiography for renovascular disorders. Based on our experience, we have formulated an algorithm for the evaluation of the hypertensive pediatric patient. The initial step is careful clinical and laboratory screening to identify those patients that are likely to have essential hypertension and who should not undergo imaging tests. In the cases where there is a possible secondary etiology, renal ultrasound is usually performed first to identify parenchymal disease. If catecholamines are elevated, then abdominal computed tomography is the initial test. If no etiology is identified from these noninvasive studies, then direct intraarterial renal angiography is performed. The authors do not feel that excretory urography, radionuclide renography, intravenous digital subtraction angiography or selective renal vein sampling for renin are useful or practical screening tests for renovascular hypertension. (orig.)

  15. Pediatric hypertension: An approach to imaging

    Energy Technology Data Exchange (ETDEWEB)

    Diament, M J; Stanley, P; Gilsanz, V; Boechat, M I; Kangarloo, H; Lieberman, E R

    1986-09-01

    Since 1981, we have made diagnoses of secondary hypertension using state of art imaging equipment in 18 pediatric patients. The most valuable tests were ultrasound identifying renal parenchymal disease, computed body tomography for adrenal tumors and intra-arterial renal angiography for renovascular disorders. Based on our experience, we have formulated an algorithm for the evaluation of the hypertensive pediatric patient. The initial step is careful clinical and laboratory screening to identify those patients that are likely to have essential hypertension and who should not undergo imaging tests. In the cases where there is a possible secondary etiology, renal ultrasound is usually performed first to identify parenchymal disease. If catecholamines are elevated, then abdominal computed tomography is the initial test. If no etiology is identified from these noninvasive studies, then direct intraarterial renal angiography is performed. The authors do not feel that excretory urography, radionuclide renography, intravenous digital subtraction angiography or selective renal vein sampling for renin are useful or practical screening tests for renovascular hypertension.

  16. Right ventricular function late after total repair of tetralogy of Fallot

    Energy Technology Data Exchange (ETDEWEB)

    Straten, Alexander van; Roos, Albert de [Leiden University Medical Center, Department of Radiology, Leiden (Netherlands); Vliegen, Hubert W. [Leiden University Medical Center, Department of Cardiology, Leiden (Netherlands); Hazekamp, Mark G. [Leiden University Medical Center, Department of Cardiothoracic Surgery, Leiden (Netherlands)

    2005-04-01

    Over the past decades, life expectancy in patients with congenital heart disease has increased dramatically. However, serious complications may develop late after total repair in infancy. These complications are usually the result of longstanding pulmonary regurgitation, which leads to dilatation of the right ventricle and an increased risk for severe arrhythmias. Therefore lifelong follow-up in these patients is required. Cardiac magnetic resonance imaging is the current imaging tool of choice because it offers superior imaging quality and enables accurate quantification of functional parameters such as flow volumes and systolic and diastolic performance. (orig.)

  17. Right ventricular function late after total repair of tetralogy of Fallot

    International Nuclear Information System (INIS)

    Straten, Alexander van; Roos, Albert de; Vliegen, Hubert W.; Hazekamp, Mark G.

    2005-01-01

    Over the past decades, life expectancy in patients with congenital heart disease has increased dramatically. However, serious complications may develop late after total repair in infancy. These complications are usually the result of longstanding pulmonary regurgitation, which leads to dilatation of the right ventricle and an increased risk for severe arrhythmias. Therefore lifelong follow-up in these patients is required. Cardiac magnetic resonance imaging is the current imaging tool of choice because it offers superior imaging quality and enables accurate quantification of functional parameters such as flow volumes and systolic and diastolic performance. (orig.)

  18. Magnetic Resonance Mediated Radio Frequency Coagulation for Vascular Repair

    Science.gov (United States)

    Zhao, Ming

    Purpose. Magnetic Resonance Mediated Radiofrequency Coagulation employs the RF heating effect of MRI scanning to coagulate biomaterials for repair of vascular defects. Coagulation of a protein biomaterial by MR-induced RF heating is a novel means to effect repair of defects such as aneurysms or arteriovenous malformations. Our novel method is to coagulate a thermosetting material (such as egg white, which can be used for investigating heat coagulation behavior and MR relaxation properties) delivered endovascularly by catheter and coagulated by RF-induced heating of an intracatheter resonant wire antenna in the scanner. Methods. Experiments were performed on a Siemens 1.5 T MRI scanner and a Bruker 14T NMR spectrometer. Egg white was brought to equilibrium at seven temperatures (20, 30, 40, 50, 60, 70 and 37 °C) in sequence. Measurement of the water spin-lattice relaxation time Ti, spin-spin relaxation time T2, spin-lattice relaxation time in the rotating frame T1p, or full width at half maximum of the MT spectrum were performed at each temperature. Relaxation parameters of raw egg white and egg white after coagulation at 70 °C were measured in the scanner at 20 °C to determine optimum inversion time, echo time and offset frequency for good image contrast between coagulated and uncoagulated protein. Finally, coagulation of egg white within a glass aneurysm phantom by RF heating in the scanner was performed to demonstrate the MR coagulation methodology and the ability to achieve image contrast between coagulated and uncoagulated biomaterial. Results. Water T2, T1p and MT gave the most definitive indication of the change from uncoagulated at low temperature to fully coagulated at 60 °C, while water T1 showed only the expected gradual increase with temperature, and no response to coagulation. MT weighted imaging is expected to be the optimum method to establish the coagulation condition of the biomaterial.

  19. BiPOD Arthroscopic Acromioclavicular Repair Restores Bidirectional Stability.

    Science.gov (United States)

    De Beer, Joe; Schaer, Michael; Latendresse, Kim; Raniga, Sumit; Moor, Beat K; Zumstein, Matthias A

    2017-01-01

    Stabilizing the acromioclavicular joint in the vertical and horizontal planes is challenging, and most current techniques do not reliably achieve this goal. The BiPOD repair is an arthroscopically assisted procedure performed with image intensifier guidance that reconstructs the coracoclavicular ligaments as well as the acromioclavicular ligaments to achieve bidirectional stability. Repair is achieved with a combination of 2-mm FiberTape (Arthrex, Naples, Florida) and 20-mm Poly-Tape (Neoligaments, Leeds, England) to achieve rigid repair, prevent bone abrasion, and promote tissue ingrowth. This study is a prospective review of the first 6 patients treated for high-grade acute acromioclavicular injury with the BiPOD technique. The study included 6 men who were 21 to 36 years old (mean, 27 years). At 6-month follow-up, complications were recorded and radiographic analysis was used to determine the coracoclavicular distance for vertical reduction and the amount of acromioclavicular translation on the Alexander axillary view was used to determine horizontal reduction. One patient had a superficial infection over the tape knot. The difference in coracoclavicular distance between the operated side and the uninvolved side was 9±2 mm preoperatively and 0.3±2 mm at 6-month follow-up. On Alexander axillary view, all 6 patients showed stable reduction, which is defined as a clavicle that is in line with the acromion. The findings show that BiPOD acromioclavicular reconstruction restores bidirectional stability of the acromioclavicular joint at 6 months. [Orthopedics. 2017; 40(1):e35-e43.]. Copyright 2016, SLACK Incorporated.

  20. Fatigue strength of repaired cracks in welded connections made of very high strength steels

    NARCIS (Netherlands)

    Akyel, A.

    2017-01-01

    For cyclically loaded structures, fatigue design becomes one of the important design criteria. The state of art shows that with modification of the conventional structural design methodology, the use of very high strength steels may have a positive effect on fatigue strength of welded connections.